WorldWideScience

Sample records for pet genotype-corrected ace

  1. Gender difference of serum angiotensin-converting enzyme (ACE) activity in DD genotype of ACE insertion/deletion polymorphism in elderly Chinese.

    Science.gov (United States)

    Zhang, Ya-Feng; Cheng, Qiong; Tang, Nelson L S; Chu, Tanya T W; Tomlinson, Brian; Liu, Fan; Kwok, Timothy C Y

    2014-12-01

    In this study we investigated the gender difference of serum angiotensin-converting enzyme (ACE) activity in a population of Hong Kong-dwelling elderly Chinese. A total of 1767 (843 male, 924 female) Hong Kong-dwelling elderly Chinese were recruited. ACE I/D genotypes were identified by polymerase chain reaction amplification and serum ACE activity was determined using a commercially available kinetic kit. ACE I/D genotype distribution was compared by chi-square test, the correlation between ACE I/D polymorphism and serum ACE activity was analysed by ANOVA test and gender difference of serum ACE activity of different genotypes was compared by independent sample t-test. No statistically significant difference of genotype distribution between male and female subjects was found. Serum ACE activity was significantly correlated with ACE genotype. Overall, there was no gender difference of serum ACE activity; however, when sub-grouping the subjects by ACE I/D genotype, male subjects with DD genotype had higher serum ACE activity than female subjects with DD genotype. No significant gender difference of genotype distribution was found in elderly Chinese. Serum ACE activity was significantly correlated with ACE I/D polymorphism in elderly Chinese. Male subjects with DD genotype had higher serum ACE activity than female subjects with DD genotype. © The Author(s) 2013.

  2. Hypoglycemia, S-ACE and ACE genotypes in a Danish nationwide population of children and adolescents with type 1 diabetes

    DEFF Research Database (Denmark)

    Johannesen, Jesper; Svensson, Jannet; Bergholdt, Regine

    2011-01-01

    OBJECTIVE: High S-ACE levels have been shown to predispose to increased risk of hypoglycemia, however; some inconsistency relates to the risk of the ACE genotype. We investigated the association between S-ACE level at diagnosis and ACE genotype to long-term risk of severe hypoglycemia in more than...... to increased risk of hypoglycemia generated from a negative binominal model were long diabetes duration (p high S-ACE level (p = 0.0497) when adjusted for ACE genotype. In the stratified analysis, S-ACE and insulin dosage were associated with hypoglycemia in girls (p = 0.026 and 0...

  3. ACE I/D genotype, adiposity, and blood pressure in children

    Directory of Open Access Journals (Sweden)

    Rothschild Max

    2009-03-01

    Full Text Available Abstract Background Angiotensin converting enzyme (ACE is a possible candidate gene that may influence both body fatness and blood pressure. Although several genetic studies have been conducted in adults, relatively few studies have examined the contribution of potential candidate genes, and specifically ACE I/D, on adiposity and BP phenotypes in childhood. Such studies may prove insightful for the development of the obesity-hypertension phenotype early in life. The purpose of this study was to examine differences in body fatness and resting blood pressure (BP by ACE I/D genotype, and determine if the association between adiposity and BP varies by ACE I/D genotype in children. Methods 152 children (75 girls, 77 boys were assessed for body composition (% body fat using dual energy x-ray absorbtiometry and resting BP according to American Heart Association recommendations. Buccal cell samples were genotyped using newly developed PCR-RFLP tests for two SNPs (rs4341 and rs4343 in complete linkage disequilibrium with the ACE I/D polymorphism. Partial correlations were computed to assess the ociations between % body fat and BP in the total sample and by genotype. ANCOVA was used to examine differences in resting BP by ACE I/D genotype and fatness groups. Results Approximately 39% of youth were overfat based on % body fat (>30% fat in girls, 25% fat in boys. Body mass, body mass index, and fat-free mass were significantly higher in the ACE D-carriers compared to the II group (p Conclusion ACE D-carriers are heavier than ACE II children; however, BP did not differ by ACE I/D genotype but was adversely influenced in the overfat D-carriers. Further studies are warranted to investigate the genetics of fatness and BP phenotypes in children.

  4. Hypoglycemia, S-ACE and ACE genotypes in a Danish nationwide population of children and adolescents with type 1 diabetes

    DEFF Research Database (Denmark)

    Johannesen, Jesper; Svensson, Jannet; Bergholdt, Regine

    2011-01-01

    High S-ACE levels have been shown to predispose to increased risk of hypoglycemia, however; some inconsistency relates to the risk of the ACE genotype. We investigated the association between S-ACE level at diagnosis and ACE genotype to long-term risk of severe hypoglycemia in more than 1000 chil...... children and adolescents with type 1 diabetes being part of the Danish Registry of Childhood diabetes over a 10-yr period....

  5. DD genotype of ACE gene in boys: may it be a risk factor for minimal change nephrotic syndrome?

    Science.gov (United States)

    Alasehirli, Belgin; Balat, Ayşe; Büyükçelik, Mithat

    2012-01-01

    It has been shown that angiotensin-converting enzyme (ACE) gene insertion/deletion (I/D) polymorphism affects the circulating and cellular levels of ACE and may be a risk factor in several renal diseases. We analyzed the association of ACE gene I/D polymorphism with the clinical presentation of minimal change nephrotic syndrome (MCNS) in a Turkish child population. This study consisted of 97 children with MCNS and 144 healthy controls. Genotyping of ACE gene was performed using polymerase chain reaction (PCR). The distributions of ACE genotypes were II in 13%, ID in 49%, and DD in 38% in patient group, and 9%, 49%, and 42% in control group, respectively. The frequency of the D allele was 63% and that of the I allele was 37% in patients. There were no relevant differences in the allele frequencies and genotypes of ACE I/D polymorphism between patients and controls. However, DD genotype was higher in boys in children with MCNS (78.4%. vs. 50.0%, p = 0.004). The frequencies of DD genotype and D allele in boys were 7.25 and 2.56 times higher than II genotype and I allele in the patient group, respectively. We suggest that DD genotype in boys may be one of the risk factors for MCNS.

  6. High prevalence of ACE DD genotype among north Indian end stage renal disease patients

    Directory of Open Access Journals (Sweden)

    Pandirikkal Baburajan Vinod

    2006-10-01

    Full Text Available Abstract Background The Renin-Angiotensin system (RAS is a key regulator of both blood pressure and kidney functions and their interaction. In such a situation, genetic variability in the genes of different components of RAS is likely to contribute for its heterogeneous association in the renal disease patients. Angiotensin converting enzyme-1 (ACE-1 is an important component of RAS which determines the vasoactive peptide Angiotensin-II. Methods In the present study, we have investigated 127 ESRD patients and 150 normal healthy controls from north India to deduce the association between ACE gene polymorphism and ESRD. The inclusion criteria for patients included a constantly elevated serum creatinine level above normal range (ranging from 3.4 to 15.8 and further the patients were recommended for renal transplantation. A total of 150 normal healthy controls were also genotyped for ACE I/D polymorphism. The criterion of defining control sample as normal was totally based on the absence of any kidney disease determined from the serum creatinin level. Genotyping of ACE I/D were assayed by polymerase chain reaction (PCR based DNA amplification using specific flanking primers Based on the method described elsewhere. Results The difference of DD and II genotypes was found highly significant among the two groups (p = 0.025; OR = 3.524; 95%CI = 1.54-8.07. The combined genotype DD v/s ID+II comparison validated that DD genotype is a high risk genotype for ESRD (p = 0.001; OR = 5.74; 95%CI limit = 3.4-8.5. However, no correlation was obtained for different biochemical parameters of lipid profile and renal function among DD and non DD genotype. Interestingly, ~87% of the DD ESRD patients were found hypertensive in comparison to the 65% patients of non DD genotype Conclusion Based on these observations we conclude that ACE DD genotype implicate a strong possible role in the hypertensive state and in renal damage among north Indians. The study will help in

  7. DD Genotype of ACE I/D Polymorphism Might Confer Protection against Dental Caries in Polish Children.

    Science.gov (United States)

    Olszowski, Tomasz; Adler, Grażyna; Janiszewska-Olszowska, Joanna; Safranow, Krzysztof; Chlubek, Dariusz

    2015-01-01

    The aim of the study was to examine the frequencies of the genotypes and alleles of ACE insertion/deletion (I/D) polymorphism and their association with dental caries in a sample of Polish children. The study subjects were 120 children with dental caries experience (cases) and 41 caries-free individuals (controls). The genotyping was performed using polymerase chain reaction. The genotype distributions of ACE I/D polymorphism were not statistically different between carious and control children. However, we found a borderline overrepresentation of the II + ID genotypes versus the DD genotype in the carious compared to the control group (69.2% and 51.2%, respectively, p = 0.057). Logistic regression analysis adjusted for age and sex revealed that I allele carriage was a significant predictor of dental caries susceptibility (OR = 2.14, 95% CI = 1.02-4.49, p = 0.041). In conclusion, the DD genotype of ACE I/D polymorphism might be protective against dental caries in Polish children. © 2015 S. Karger AG, Basel.

  8. ACE DD genotype is unfavorable to Korean short-term muscle power athletes.

    Science.gov (United States)

    Kim, C-H; Cho, J-Y; Jeon, J Y; Koh, Y G; Kim, Y-M; Kim, H-J; Park, M; Um, H-S; Kim, C

    2010-01-01

    The purpose of this study was to test the hypothesis that the ACE DD genotype is unfavorably associated with the ultimate power-oriented performance. To test the hypothesis we recruited a total of 848 subjects including 55 international level power-oriented athletes (High-performance), 100 national level power-oriented athletes (Mid-performance) and 693 healthy controls (Control) in Korea. Then the distributions of ACE polymorphism throughout these groups were analyzed. As a result, there was a gradual decrease of frequencies of the DD genotype with advancing levels of performance (Control vs. Mid-performance vs. High-performance=17.2% vs. 10.0% vs. 5.5%, p=0.002). Also, the frequencies of D allele decreased gradually with advancing levels of performance (Control vs. Mid-performance vs. High-performance=42.6% vs. 35.0% vs. 30.9%, pDD genotype and the D allele. This finding gave 3.83 times lower probability of success in power-oriented sports for individuals with the DD genotype than those with the II+ ID genotype. In conclusion, these results indicate that Korean power-oriented athletes with a lower frequency of the DD genotype had a lower probability of success in power-oriented sports. Georg Thieme Verlag KG Stuttgart, New York.

  9. Associations of ACE Gene Insertion/Deletion Polymorphism, ACE Activity, and ACE mRNA Expression with Hypertension in a Chinese Population

    Science.gov (United States)

    He, Qingfang; Fan, Chunhong; Yu, Min; Wallar, Gina; Zhang, Zuo-Feng; Wang, Lixin; Zhang, Xinwei; Hu, Ruying

    2013-01-01

    Background The present study was designed to explore the association of angiotensin converting enzyme (ACE) gene insertion/deletion (I/D, rs4646994) polymorphism, plasma ACE activity, and circulating ACE mRNA expression with essential hypertension (EH) in a Chinese population. In addition, a new detection method for circulating ACE mRNA expression was explored. Methods The research was approved by the ethics committee of Zhejiang Provincial Center for Disease Prevention and Control. Written informed consent was obtained prior to the investigation. 221 hypertensives (cases) and 221 normotensives (controls) were interviewed, subjected to a physical examination, and provided blood for biochemical and genetic tests. The ACE mRNA expression was analyzed by real time fluorescent quantitative Reverse Transcription PCR (FQ-RT-PCR). We performed logistic regression to assess associations of ACE I/D genotypes, ACE activity, and ACE mRNA expression levels with hypertension. Results The results of the multivariate logistic regression analysis showed that the additive model (ID, DD versus II) of the ACE genotype revealed an association with hypertension with adjusted OR of 1.43(95% CI: 1.04-1.97), and ACE ID genotype with adjusted OR of 1.72(95% CI: 1.01-2.92), DD genotype with adjusted OR of 1.94(95% CI: 1.01-3.73), respectively. In addition, our data also indicate that plasma ACE activity (adjusted OR was 1.13(95% CI: 1.08-1.18)) was significantly related to hypertension. However, the plasma ACE mRNA expressions were not different between the cases and controls. Conclusion ACE I/D polymorphism and ACE activity revealed significant influence on hypertension, while circulating ACE mRNA expression was not important factors associated with hypertension in this Chinese population. The detection of circulating ACE mRNA expression by FQ-RT-PCR might be a useful method for early screening and monitoring of EH. PMID:24098401

  10. Magnetic Resonance-based Motion Correction for Quantitative PET in Simultaneous PET-MR Imaging.

    Science.gov (United States)

    Rakvongthai, Yothin; El Fakhri, Georges

    2017-07-01

    Motion degrades image quality and quantitation of PET images, and is an obstacle to quantitative PET imaging. Simultaneous PET-MR offers a tool that can be used for correcting the motion in PET images by using anatomic information from MR imaging acquired concurrently. Motion correction can be performed by transforming a set of reconstructed PET images into the same frame or by incorporating the transformation into the system model and reconstructing the motion-corrected image. Several phantom and patient studies have validated that MR-based motion correction strategies have great promise for quantitative PET imaging in simultaneous PET-MR. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Association of Angiotensin-Converting Enzyme ACE Gene Polymorphism with ACE Activity and Susceptibility to Vitiligo in Egyptian Population.

    Science.gov (United States)

    Badran, Dahlia I; Nada, Hesham; Hassan, Ranya

    2015-05-01

    The insertion/deletion (I/D) polymorphism of the angiotensin-converting enzyme (ACE) gene is associated with vitiligo in the Indians and Koreans, but not in those of English or Turkish background. We investigated the ACE (I/D) polymorphism in vitiligo patients for the first time in Egypt and compared serum ACE levels between vitiligo patients and controls. The present study was carried out in 100 vitiligo patients (40 males and 60 females) and in 100 healthy controls of an Egyptian population using the polymerase chain reaction genotyping method. The ACE genotype and allele frequency was significantly different between vitiligo patients and controls. Our results revealed a significant increase in the frequency of the ACE I allele (p=0.002; odds ratio: 1.99; 95% confidence intervals: 1.207-3.284) with an overrepresentation of I/D genotype in the vitiligo patient group. Furthermore, there was a significant difference between the segmental, nonsegmental, and focal vitiligo in ACE gene genotype distribution. Serum ACE levels were significantly increased in vitiligo patients compared to controls (p=0.034). This study suggests that, for the first time, ACE gene polymorphism confers susceptibility to vitiligo in the Egyptian population.

  12. An attenuation correction method for PET/CT images

    International Nuclear Information System (INIS)

    Ue, Hidenori; Yamazaki, Tomohiro; Haneishi, Hideaki

    2006-01-01

    In PET/CT systems, accurate attenuation correction can be achieved by creating an attenuation map from an X-ray CT image. On the other hand, respiratory-gated PET acquisition is an effective method for avoiding motion blurring of the thoracic and abdominal organs caused by respiratory motion. In PET/CT systems employing respiratory-gated PET, using an X-ray CT image acquired during breath-holding for attenuation correction may have a large effect on the voxel values, especially in regions with substantial respiratory motion. In this report, we propose an attenuation correction method in which, as the first step, a set of respiratory-gated PET images is reconstructed without attenuation correction, as the second step, the motion of each phase PET image from the PET image in the same phase as the CT acquisition timing is estimated by the previously proposed method, as the third step, the CT image corresponding to each respiratory phase is generated from the original CT image by deformation according to the motion vector maps, and as the final step, attenuation correction using these CT images and reconstruction are performed. The effectiveness of the proposed method was evaluated using 4D-NCAT phantoms, and good stability of the voxel values near the diaphragm was observed. (author)

  13. The presence of PAI-1 4G/5G and ACE DD genotypes increases the risk of early-stage AVF thrombosis in hemodialysis patients.

    Science.gov (United States)

    Güngör, Yahya; Kayataş, Mansur; Yıldız, Gürsel; Özdemir, Öztürk; Candan, Ferhan

    2011-01-01

    In this study, we investigated the relationship between early arteriovenous fistula (AVF) thrombosis with angiotensin-converting enzyme (ACE) gene and thrombophilic factor gene polymorphisms. Thirty-five patients who suffered from three or more fistula thrombosis episodes in the early period after AVF operation and 33 control patients with no history of thrombosis for at least 3 years were enrolled in this study. Factor V G1691A Leiden, factor V H1299R (R2), prothrombin G20210A, factor XIIIV34L, β-fibrinogen-455 G-A, glycoprotein IIIa L33P human platelet antigens (HPA-1), methylenetetrahydrofolate reductase C677T, and methylenetetrahydrofolate reductase A1298C gene polymorphisms were similar in both groups (p > 0.05). Plasminogen activator inhibitor 1 (PAI-1) 4G/5G genotype in the study group and 4G/4G genotype in the control group were significantly higher (p = 0.014). No significant difference was detected in terms of the 5G/5G genotype. With regard to the ACE gene polymorphism, the control group showed more ID genotype (19/33, 57.6%), whereas the study group showed more DD genotype (17/35, 48.6%). II genotype was similar in both groups (x(2) = 7.40, p = 0.025). The rate of ACE inhibitor-angiotensin II receptor blockers use was 5/35 in the study group (14.3%) and 5/33 in the control group (15.2%). Individuals with PAI-1 4G/5G genotype showed 5.03 times more risk of thrombosis when compared with 4G/4G and 5G/5G genotypes [p = 0.008, OR = 5.03, 95% confidence interval (1.44:17.64)]. Individuals with ACE DD genotype showed 4.25 times more risk of thrombosis when compared with II and ID [p = 0.008, OR = 4.25, 95% confidence interval (1.404:12.83)]. PAI-1 4G/5G and ACE DD genotypes are associated with increased risk for early AVF thrombosis.

  14. ACE polymorphism does not determine short-term renal response to ACE-inhibition in proteinuric patients

    NARCIS (Netherlands)

    vanderKleij, FGH; Navis, GJ; Gansevoort, RT; Scheffer, H; deZeeuw, D; deJong, PE

    1997-01-01

    Background. The renal response to ACE inhibition is known to vary between individuals. The ACE genotype is a determinant of the ACE concentrations in plasma and tissue, and therefore might affect the renal response to ACE inhibition in renal patients. Methods. To test this hypothesis we studied the

  15. Effect of Attenuation Correction on Regional Quantification Between PET/MR and PET/CT

    DEFF Research Database (Denmark)

    Teuho, Jarmo; Johansson, Jarkko; Linden, Jani

    2016-01-01

    UNLABELLED: A spatial bias in brain PET/MR exists compared with PET/CT, because of MR-based attenuation correction. We performed an evaluation among 4 institutions, 3 PET/MR systems, and 4 PET/CT systems using an anthropomorphic brain phantom, hypothesizing that the spatial bias would be minimized....../MR systems, CTAC was applied as the reference method for attenuation correction. RESULTS: With CTAC, visual and quantitative differences between PET/MR and PET/CT systems were minimized. Intersystem variation between institutions was +3.42% to -3.29% in all VOIs for PET/CT and +2.15% to -4.50% in all VOIs...... for PET/MR. PET/MR systems differed by +2.34% to -2.21%, +2.04% to -2.08%, and -1.77% to -5.37% when compared with a PET/CT system at each institution, and these differences were not significant (P ≥ 0.05). CONCLUSION: Visual and quantitative differences between PET/MR and PET/CT systems can be minimized...

  16. MR-based attenuation correction for cardiac FDG PET on a hybrid PET/MRI scanner: comparison with standard CT attenuation correction

    Energy Technology Data Exchange (ETDEWEB)

    Vontobel, Jan; Liga, Riccardo; Possner, Mathias; Clerc, Olivier F.; Mikulicic, Fran; Veit-Haibach, Patrick; Voert, Edwin E.G.W. ter; Fuchs, Tobias A.; Stehli, Julia; Pazhenkottil, Aju P.; Benz, Dominik C.; Graeni, Christoph; Gaemperli, Oliver; Herzog, Bernhard; Buechel, Ronny R.; Kaufmann, Philipp A. [University Hospital Zurich, Department of Nuclear Medicine, Zurich (Switzerland)

    2015-09-15

    The aim of this study was to evaluate the feasibility of attenuation correction (AC) for cardiac {sup 18}F-labelled fluorodeoxyglucose (FDG) positron emission tomography (PET) using MR-based attenuation maps. We included 23 patients with no known cardiac history undergoing whole-body FDG PET/CT imaging for oncological indications on a PET/CT scanner using time-of-flight (TOF) and subsequent whole-body PET/MR imaging on an investigational hybrid PET/MRI scanner. Data sets from PET/MRI (with and without TOF) were reconstructed using MR AC and semi-quantitative segmental (20-segment model) myocardial tracer uptake (per cent of maximum) and compared to PET/CT which was reconstructed using CT AC and served as standard of reference. Excellent correlations were found for regional uptake values between PET/CT and PET/MRI with TOF (n = 460 segments in 23 patients; r = 0.913; p < 0.0001) with narrow Bland-Altman limits of agreement (-8.5 to +12.6 %). Correlation coefficients were slightly lower between PET/CT and PET/MRI without TOF (n = 460 segments in 23 patients; r = 0.851; p < 0.0001) with broader Bland-Altman limits of agreement (-12.5 to +15.0 %). PET/MRI with and without TOF showed minimal underestimation of tracer uptake (-2.08 and -1.29 %, respectively), compared to PET/CT. Relative myocardial FDG uptake obtained from MR-based attenuation corrected FDG PET is highly comparable to standard CT-based attenuation corrected FDG PET, suggesting interchangeability of both AC techniques. (orig.)

  17. Coincidence detection FDG-PET (Co-PET) in the management of oncological patients: attenuation correction versus non-attenuation correction

    International Nuclear Information System (INIS)

    Chan, W.L.; Freund, J.; Pocock, N.; Szeto, E.; Chan, F.; Sorensen, B.; McBride, B.

    2000-01-01

    Full text: This study was to determine if attenuation correction (AC) in FDG Co-PET improved image quality, lesion detection, patient staging and management of various malignant neoplasms, compared to non-attenuation-corrected (NAC) images. Thirty patients (25 men, 5 women, mean age 58 years) with known or suspected malignant neoplasms, including non-small-cell lung cancer, non Hodgkin's and Hodgkin's lymphoma, carcinoma of the breast, head and neck cancer and melanoma, underwent FDG Co-PET, which was correlated with histopathology, CT and other conventional imaging modalities and clinical follow-up. Whole body tomography was performed (ADAC Vertex MCD) 60 min after 200 MBq of 18 F-FDG (>6h fasting). The number and location of FDG avid lesions detected on the AC images and NAC Co-PET images were blindly assessed by two independent observers. Semi-quantitative grading of image clarity and lesion-to-background quality was performed. This revealed markedly improved image clarity and lesion-to-background quality, in the AC versus NAC images. AC and NAC Co-PET were statistically different in relation to lesion detection (p<0.01) and tumour staging (p<0.0 1). NAC Co-PET demonstrated 51 of the 65 lesions (78%) detected by AC Co-PET. AC Co-PET staging was correct in 27 patients (90%), compared with NAC Co-PET in 22 patients (73%). AC Co-PET altered tumour staging in five of 30 patients (16%) and NAC Co-PET did not alter tumour staging in any of the patients- management was altered in only two of these five patients (7%). In conclusion, AC Co-PET resulted in better image quality with significantly improved lesion detectability and tumour staging compared to NAC Co-PET. Its additional impact on patient management in this relatively small sample was minor. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  18. PET motion correction in context of integrated PET/MR: Current techniques, limitations, and future projections.

    Science.gov (United States)

    Gillman, Ashley; Smith, Jye; Thomas, Paul; Rose, Stephen; Dowson, Nicholas

    2017-12-01

    Patient motion is an important consideration in modern PET image reconstruction. Advances in PET technology mean motion has an increasingly important influence on resulting image quality. Motion-induced artifacts can have adverse effects on clinical outcomes, including missed diagnoses and oversized radiotherapy treatment volumes. This review aims to summarize the wide variety of motion correction techniques available in PET and combined PET/CT and PET/MR, with a focus on the latter. A general framework for the motion correction of PET images is presented, consisting of acquisition, modeling, and correction stages. Methods for measuring, modeling, and correcting motion and associated artifacts, both in literature and commercially available, are presented, and their relative merits are contrasted. Identified limitations of current methods include modeling of aperiodic and/or unpredictable motion, attaining adequate temporal resolution for motion correction in dynamic kinetic modeling acquisitions, and maintaining availability of the MR in PET/MR scans for diagnostic acquisitions. Finally, avenues for future investigation are discussed, with a focus on improvements that could improve PET image quality, and that are practical in the clinical environment. © 2017 American Association of Physicists in Medicine.

  19. Impact of improved attenuation correction featuring a bone atlas and truncation correction on PET quantification in whole-body PET/MR.

    Science.gov (United States)

    Oehmigen, Mark; Lindemann, Maike E; Gratz, Marcel; Kirchner, Julian; Ruhlmann, Verena; Umutlu, Lale; Blumhagen, Jan Ole; Fenchel, Matthias; Quick, Harald H

    2018-04-01

    Recent studies have shown an excellent correlation between PET/MR and PET/CT hybrid imaging in detecting lesions. However, a systematic underestimation of PET quantification in PET/MR has been observed. This is attributable to two methodological challenges of MR-based attenuation correction (AC): (1) lack of bone information, and (2) truncation of the MR-based AC maps (μmaps) along the patient arms. The aim of this study was to evaluate the impact of improved AC featuring a bone atlas and truncation correction on PET quantification in whole-body PET/MR. The MR-based Dixon method provides four-compartment μmaps (background air, lungs, fat, soft tissue) which served as a reference for PET/MR AC in this study. A model-based bone atlas provided bone tissue as a fifth compartment, while the HUGE method provided truncation correction. The study population comprised 51 patients with oncological diseases, all of whom underwent a whole-body PET/MR examination. Each whole-body PET dataset was reconstructed four times using standard four-compartment μmaps, five-compartment μmaps, four-compartment μmaps + HUGE, and five-compartment μmaps + HUGE. The SUV max for each lesion was measured to assess the impact of each μmap on PET quantification. All four μmaps in each patient provided robust results for reconstruction of the AC PET data. Overall, SUV max was quantified in 99 tumours and lesions. Compared to the reference four-compartment μmap, the mean SUV max of all 99 lesions increased by 1.4 ± 2.5% when bone was added, by 2.1 ± 3.5% when HUGE was added, and by 4.4 ± 5.7% when bone + HUGE was added. Larger quantification bias of up to 35% was found for single lesions when bone and truncation correction were added to the μmaps, depending on their individual location in the body. The novel AC method, featuring a bone model and truncation correction, improved PET quantification in whole-body PET/MR imaging. Short reconstruction times, straightforward

  20. Impact of improved attenuation correction featuring a bone atlas and truncation correction on PET quantification in whole-body PET/MR

    Energy Technology Data Exchange (ETDEWEB)

    Oehmigen, Mark; Lindemann, Maike E. [University Hospital Essen, High Field and Hybrid MR Imaging, Essen (Germany); Gratz, Marcel; Quick, Harald H. [University Hospital Essen, High Field and Hybrid MR Imaging, Essen (Germany); University Duisburg-Essen, Erwin L. Hahn Institute for MR Imaging, Essen (Germany); Kirchner, Julian [University Dusseldorf, Department of Diagnostic and Interventional Radiology, Medical Faculty, Dusseldorf (Germany); Ruhlmann, Verena [University Hospital Essen, Department of Nuclear Medicine, Essen (Germany); Umutlu, Lale [University Hospital Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Blumhagen, Jan Ole; Fenchel, Matthias [Siemens Healthcare GmbH, Erlangen (Germany)

    2018-04-15

    Recent studies have shown an excellent correlation between PET/MR and PET/CT hybrid imaging in detecting lesions. However, a systematic underestimation of PET quantification in PET/MR has been observed. This is attributable to two methodological challenges of MR-based attenuation correction (AC): (1) lack of bone information, and (2) truncation of the MR-based AC maps (μmaps) along the patient arms. The aim of this study was to evaluate the impact of improved AC featuring a bone atlas and truncation correction on PET quantification in whole-body PET/MR. The MR-based Dixon method provides four-compartment μmaps (background air, lungs, fat, soft tissue) which served as a reference for PET/MR AC in this study. A model-based bone atlas provided bone tissue as a fifth compartment, while the HUGE method provided truncation correction. The study population comprised 51 patients with oncological diseases, all of whom underwent a whole-body PET/MR examination. Each whole-body PET dataset was reconstructed four times using standard four-compartment μmaps, five-compartment μmaps, four-compartment μmaps + HUGE, and five-compartment μmaps + HUGE. The SUV{sub max} for each lesion was measured to assess the impact of each μmap on PET quantification. All four μmaps in each patient provided robust results for reconstruction of the AC PET data. Overall, SUV{sub max} was quantified in 99 tumours and lesions. Compared to the reference four-compartment μmap, the mean SUV{sub max} of all 99 lesions increased by 1.4 ± 2.5% when bone was added, by 2.1 ± 3.5% when HUGE was added, and by 4.4 ± 5.7% when bone + HUGE was added. Larger quantification bias of up to 35% was found for single lesions when bone and truncation correction were added to the μmaps, depending on their individual location in the body. The novel AC method, featuring a bone model and truncation correction, improved PET quantification in whole-body PET/MR imaging. Short reconstruction times, straightforward

  1. Aerobic exercise training differentially affects ACE C- and N-domain activities in humans: Interactions with ACE I/D polymorphism and association with vascular reactivity.

    Science.gov (United States)

    Alves, Cléber Rene; Fernandes, Tiago; Lemos, José Ribeiro; Magalhães, Flávio de Castro; Trombetta, Ivani Credidio; Alves, Guilherme Barreto; Mota, Glória de Fátima Alves da; Dias, Rodrigo Gonçalves; Pereira, Alexandre Costa; Krieger, José Eduardo; Negrão, Carlos Eduardo; Oliveira, Edilamar Menezes

    2018-01-01

    Previous studies have linked angiotensin-converting enzyme ( ACE) insertion (I)/deletion (D) polymorphism (II, ID and DD) to physical performance. Moreover, ACE has two catalytic domains: NH2 (N) and COOH (C) with distinct functions, and their activity has been found to be modulated by ACE polymorphism. The aim of the present study is to investigate the effects of the interaction between aerobic exercise training (AET) and ACE I/D polymorphism on ACE N- and C-domain activities and vascular reactivity in humans. A total of 315 pre-selected healthy males were genotyped for II, ID and DD genotypes. Fifty completed the full AET (II, n = 12; ID, n = 25; and DD, n = 13), performed in three 90-minute sessions weekly, in the four-month exercise protocol. Pre- and post-training resting heart rate (HR), peak O 2 consumption (VO 2 peak), mean blood pressure (MBP), forearm vascular conduction (FVC), total circulating ACE and C- and N-domain activities were assessed. One-way ANOVA and two -way repeated-measures ANOVA were used. In pre-training, all variables were similar among the three genotypes. In post-training, a similar increase in FVC (35%) was observed in the three genotypes. AET increased VO 2 peak similarly in II, ID and DD (49±2 vs. 57±1; 48±1 vs. 56±3; and 48±5 vs. 58±2 ml/kg/min, respectively). Moreover, there were no changes in HR and MBP. The DD genotype was also associated with greater ACE and C-domain activities at pre- and post-training when compared to II. AET decreased similarly the total ACE and C-domain activities in all genotypes, while increasing the N-domain activity in the II and DD genotypes. However, interestingly, the measurements of N-domain activity after training indicate a greater activity than the other genotypes. These results suggest that the vasodilation in response to AET may be associated with the decrease in total ACE and C-domain activities, regardless of genotype, and that the increase in N-domain activity is dependent on the DD

  2. PET motion correction using PRESTO with ITK motion estimation

    Energy Technology Data Exchange (ETDEWEB)

    Botelho, Melissa [Institute of Biophysics and Biomedical Engineering, Science Faculty of University of Lisbon (Portugal); Caldeira, Liliana; Scheins, Juergen [Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich (Germany); Matela, Nuno [Institute of Biophysics and Biomedical Engineering, Science Faculty of University of Lisbon (Portugal); Kops, Elena Rota; Shah, N Jon [Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich (Germany)

    2014-07-29

    The Siemens BrainPET scanner is a hybrid MRI/PET system. PET images are prone to motion artefacts which degrade the image quality. Therefore, motion correction is essential. The library PRESTO converts motion-corrected LORs into highly accurate generic projection data [1], providing high-resolution PET images. ITK is an open-source software used for registering multidimensional data []. ITK provides motion estimation necessary to PRESTO.

  3. PET motion correction using PRESTO with ITK motion estimation

    International Nuclear Information System (INIS)

    Botelho, Melissa; Caldeira, Liliana; Scheins, Juergen; Matela, Nuno; Kops, Elena Rota; Shah, N Jon

    2014-01-01

    The Siemens BrainPET scanner is a hybrid MRI/PET system. PET images are prone to motion artefacts which degrade the image quality. Therefore, motion correction is essential. The library PRESTO converts motion-corrected LORs into highly accurate generic projection data [1], providing high-resolution PET images. ITK is an open-source software used for registering multidimensional data []. ITK provides motion estimation necessary to PRESTO.

  4. The angiotensin-converting enzyme (ACE) gene insertion/ deletion dimorphism tracks with higher serum ace activities in both younger and older subjects

    International Nuclear Information System (INIS)

    Frossard, Philippe M.; Hill, Susan H.; Obineche, Enyioma N.; Lestringant, Gilles G.

    1998-01-01

    The absence of a 287 base pair alu sequence in the ACE gene (D allele) is associated with higher ACE levels than its presence (I allele) in adults. We carried out a case control study of thr ACE*I/D dimorphism in relation to circulating ACE activities to evaluate associations between the two variables in adults, compared to younger (18 years or less) individuals. Genotypes of the ACE*I/D dimorphism were determined on DNA samples from a population of 164 random (unrelated) Emirtaes nationals, composed of groups: 112 subjects above 18 years of age (range=20-77), and 52 subjects of 18 years or less (range=1-18) and analyzed for putative associations with serum ACE activities. ACE*I/D genotypes of the 164 individualds were determined by assays based on polymerase chain reaction. ACE activities were determined on serum samples of these subjects bu colorimetric assays. The D allele was associared with increasd ACE values in both adult and younger individuals. Mean ACE activity levels associated with II, ID and DD genotypes, however, were 42%-61% higher in the 18 years and under group of subjects. The ACE*I/D marker accounted for 28% of the variance of the phenomenon determining ACE levels in adults, and for 30% among youngsters. The ACE*I/D dimorphism is correlated strongly with circulating ACE activities in both and young Emirati, subjects and the corresponding mean ACE activities were significantly higher among the youngsters. (author)

  5. Is Necessary Attenuation Correction for Cat Brain PET?

    International Nuclear Information System (INIS)

    Kim, Jin Su; Lee, Jae Sung; Park, Min Hyun; Im, Ki Chun; Oh, Seung Ha; Lee, Dong Soo; Moon, Dae Hyuk

    2007-01-01

    Photon attenuation and scatter corrections (AC and SC) were necessary for quantification of human PET. However, there is no consensus on whether AC and SC are necessary for the cat brain PET imaging. Since post-injection transmission (TX) PET scans are not permitted or provided to microPET scanner users at present, additional time for performing TX scan and awaiting FDG uptake is required for attenuation and scatter corrections. Increasing probability of subject movement and possible biological effect of long term anesthesia would be the problem in additional TX scan. The aim of this study was to examine the effect of AC and SC for the quantification of cat brain PET data

  6. Evaluation of Sinus/Edge-Corrected Zero-Echo-Time-Based Attenuation Correction in Brain PET/MRI.

    Science.gov (United States)

    Yang, Jaewon; Wiesinger, Florian; Kaushik, Sandeep; Shanbhag, Dattesh; Hope, Thomas A; Larson, Peder E Z; Seo, Youngho

    2017-11-01

    In brain PET/MRI, the major challenge of zero-echo-time (ZTE)-based attenuation correction (ZTAC) is the misclassification of air/tissue/bone mixtures or their boundaries. Our study aimed to evaluate a sinus/edge-corrected (SEC) ZTAC (ZTAC SEC ), relative to an uncorrected (UC) ZTAC (ZTAC UC ) and a CT atlas-based attenuation correction (ATAC). Methods: Whole-body 18 F-FDG PET/MRI scans were obtained for 12 patients after PET/CT scans. Only data acquired at a bed station that included the head were used for this study. Using PET data from PET/MRI, we applied ZTAC UC , ZTAC SEC , ATAC, and reference CT-based attenuation correction (CTAC) to PET attenuation correction. For ZTAC UC , the bias-corrected and normalized ZTE was converted to pseudo-CT with air (-1,000 HU for ZTE 0.75), and bone (-2,000 × [ZTE - 1] + 42 HU for 0.2 ≤ ZTE ≤ 0.75). Afterward, in the pseudo-CT, sinus/edges were automatically estimated as a binary mask through morphologic processing and edge detection. In the binary mask, the overestimated values were rescaled below 42 HU for ZTAC SEC For ATAC, the atlas deformed to MR in-phase was segmented to air, inner air, soft tissue, and continuous bone. For the quantitative evaluation, PET mean uptake values were measured in twenty 1-mL volumes of interest distributed throughout brain tissues. The PET uptake was compared using a paired t test. An error histogram was used to show the distribution of voxel-based PET uptake differences. Results: Compared with CTAC, ZTAC SEC achieved the overall PET quantification accuracy (0.2% ± 2.4%, P = 0.23) similar to CTAC, in comparison with ZTAC UC (5.6% ± 3.5%, P PET quantification in brain PET/MRI, comparable to the accuracy achieved by CTAC, particularly in the cerebellum. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  7. ACE I/D sequence variants but not MTHFR C677T, is strongly linked to malignant glioma risk and its variant DD genotype may act as a promising predictive biomarker for overall survival of glioma patients.

    Science.gov (United States)

    Pandith, Arshad A; Qasim, Iqbal; Zahoor, Wani; Shah, Parveen; Bhat, Abdul R

    2018-01-10

    ACE I/D and MTHFR C677T gene polymorphisms can be seen as candidate genes for glioma on the basis of their biological functions and their involvement in different cancers. The aim of this study was to analyze potential association and overall survival between MTHFR C677T and ACE I/D polymorphism in glioma patients in our population. We tested genotype distribution of 112 glioma patients against 141 cancer-free controls from the same region. Kaplan-Meier survival analysis was performed to evaluate overall survival of patients for both genes. No significant differences were found among MTHFR C677T wild type C and variant genotypes CT/TT with glioma patients. In ACE, the distribution of variant ID and DD was found to be significantly higher in glioma cases as compared to controls (pACE DD genotypes were highly presented in glioma cases 26.8% versus 10.6% in controls (pACE DD genotypes had the least estimated overall survival of 13.4months in comparison to 21. 7 and 17.6months for ACE II and I/D genotypes respectively. We conclude ACE I/D polymorphism plays a vital role in predisposition of higher risk for glioma. We also suggest that ACE DD genotypes may act as an important predictive biomarker for overall survival of glioma patients. Copyright © 2017. Published by Elsevier B.V.

  8. The effect, identification and correction of misalignment between PET transmission and emission scans on brain PET imaging

    International Nuclear Information System (INIS)

    Zhang Xiangsong; He Zuoxiang; Tang Anwu; Qiao Suixian

    2004-01-01

    Objectives: To study the effect of misalignment between PET transmission and emission scans of brain on brain PET imaging, and the Methods to identify and correct it. Methods: 18F-FDG PET imaging was performed on 8 volunteers. The emission images were reconstructed with attenuation correction after some translations and rotations in the x-axis and transverse plane were given, 1 mm and 1 degree each step, respectively. The 3-D volume fusion of PET emission and transmission scans was used to identify the suspected misalignment on 10 18F-FDG PET brain imaging. Three Methods were used to correct the misalignment. First, to quantitate the amount of the misalignment by 3-D volume registration of PET emission and transmission scans, the emission images were reconstructed with corrected translations and rotations in x-direction and transverse plane. Second, the emission images were reconstructed with mathematic calculation of brain attenuation. Third, 18F-FDG PET brain imaging was redone with careful application of laser alignment. Results: The translations greater than 3 mm in x-direction and the rotations greater than 8 degrees in transverse plane could lead to visible artifacts, which were presented with decreasing radioactivity uptake in the cortex of half cerebrum and in the frontal cortex at the side in the translating or rotating direction, respectively. The 3-D volume fusion of PET emission and transmission scans could identify and quantitate the amount of misalignment between PET emission and transmission scans of brain. The PET emission images reconstructed with corrected misalignment and mathematic calculation of brain attenuation were consistent with redone PET brain imaging. Conclusions: The misalignment between PET transmission and emission scans of brain can lead to visible artifacts. The 3-D volume fusion of PET emission and transmission scans can identify and quantitate the amount of the misalignment. The visible artifacts caused by the misalignment can be

  9. Evaluation of attenuation correction in cardiac PET using PET/MR.

    Science.gov (United States)

    Lau, Jeffrey M C; Laforest, R; Sotoudeh, H; Nie, X; Sharma, S; McConathy, J; Novak, E; Priatna, A; Gropler, R J; Woodard, P K

    2017-06-01

    Simultaneous acquisition Positron emission tomography/magnetic resonance (PET/MR) is a new technology that has potential as a tool both in research and clinical diagnosis. However, cardiac PET acquisition has not yet been validated using MR imaging for attenuation correction (AC). The goal of this study is to evaluate the feasibility of PET imaging using a standard 2-point Dixon volume interpolated breathhold examination (VIBE) MR sequence for AC. Evaluation was performed in both phantom and patient data. A chest phantom containing heart, lungs, and a lesion insert was scanned by both PET/MR and PET/CT. In addition, 30 patients underwent whole-body 18 F-fluorodeoxyglucose PET/CT followed by simultaneous cardiac PET/MR. Phantom study showed 3% reduction of activity values in the myocardium due to the non-inclusion of the phased array coil in the AC. In patient scans, average standardized uptake values (SUVs) obtained by PET/CT and PET/MR showed no significant difference (n = 30, 4.6 ± 3.5 vs 4.7 ± 2.8, P = 0.47). There was excellent per patient correlation between the values acquired by PET/CT and PET/MR (R 2  = 0.97). Myocardial SUVs PET imaging using MR for AC shows excellent correlation with myocardial SUVs obtained by standard PET/CT imaging. The 2-point Dixon VIBE MR technique can be used for AC in simultaneous PET/MR data acquisition.

  10. ACE insertion/deletion (I/D) polymorphism and diabetic nephropathy.

    Science.gov (United States)

    Rahimi, Zohreh

    2012-10-01

    Angiotensin converting enzyme (ACE) gene encodes ACE, a key component of renin angiotensin system (RAS), plays an important role in blood pressure homeostasis by generating the vasoconstrictor peptide angiotensin II. Directory of Open Access Journals (DOAJ), Google Scholar, Pubmed (NLM), LISTA (EBSCO) and Web of Science have been searched. The presence of ACE insertion/deletion (I/D) polymorphism affects the plasma level of ACE. ACE DD genotype is associated with the highest systemic and renal ACE levels compared with the lowest ACE activity in carriers of II genotype. In this review focus has been performed on the study of ACE I/D polymorphism in various populations and its influence on the risk of onset and progression of diabetic nephropathy. Also, association between ACE I/D polymorphism and response to ACE inhibitor and angiotensin II receptor antagonists will be reviewed. Further, synergistic effect of this polymorphism and variants of some genes on the risk of development of diabetic nephropathy will be discussed.

  11. MRI-Based Nonrigid Motion Correction in Simultaneous PET/MRI

    Science.gov (United States)

    Chun, Se Young; Reese, Timothy G.; Ouyang, Jinsong; Guerin, Bastien; Catana, Ciprian; Zhu, Xuping; Alpert, Nathaniel M.; El Fakhri, Georges

    2014-01-01

    Respiratory and cardiac motion is the most serious limitation to whole-body PET, resulting in spatial resolution close to 1 cm. Furthermore, motion-induced inconsistencies in the attenuation measurements often lead to significant artifacts in the reconstructed images. Gating can remove motion artifacts at the cost of increased noise. This paper presents an approach to respiratory motion correction using simultaneous PET/MRI to demonstrate initial results in phantoms, rabbits, and nonhuman primates and discusses the prospects for clinical application. Methods Studies with a deformable phantom, a free-breathing primate, and rabbits implanted with radioactive beads were performed with simultaneous PET/MRI. Motion fields were estimated from concurrently acquired tagged MR images using 2 B-spline nonrigid image registration methods and incorporated into a PET list-mode ordered-subsets expectation maximization algorithm. Using the measured motion fields to transform both the emission data and the attenuation data, we could use all the coincidence data to reconstruct any phase of the respiratory cycle. We compared the resulting SNR and the channelized Hotelling observer (CHO) detection signal-to-noise ratio (SNR) in the motion-corrected reconstruction with the results obtained from standard gating and uncorrected studies. Results Motion correction virtually eliminated motion blur without reducing SNR, yielding images with SNR comparable to those obtained by gating with 5–8 times longer acquisitions in all studies. The CHO study in dynamic phantoms demonstrated a significant improvement (166%–276%) in lesion detection SNR with MRI-based motion correction as compared with gating (P < 0.001). This improvement was 43%–92% for large motion compared with lesion detection without motion correction (P < 0.001). CHO SNR in the rabbit studies confirmed these results. Conclusion Tagged MRI motion correction in simultaneous PET/MRI significantly improves lesion detection

  12. The ACE gene and human performance: 12 years on.

    Science.gov (United States)

    Puthucheary, Zudin; Skipworth, James R A; Rawal, Jai; Loosemore, Mike; Van Someren, Ken; Montgomery, Hugh E

    2011-06-01

    Some 12 years ago, a polymorphism of the angiotensin I-converting enzyme (ACE) gene became the first genetic element shown to impact substantially on human physical performance. The renin-angiotensin system (RAS) exists not just as an endocrine regulator, but also within local tissue and cells, where it serves a variety of functions. Functional genetic polymorphic variants have been identified for most components of RAS, of which the best known and studied is a polymorphism of the ACE gene. The ACE insertion/deletion (I/D) polymorphism has been associated with improvements in performance and exercise duration in a variety of populations. The I allele has been consistently demonstrated to be associated with endurance-orientated events, notably, in triathlons. Meanwhile, the D allele is associated with strength- and power-orientated performance, and has been found in significant excess among elite swimmers. Exceptions to these associations do exist, and are discussed. In theory, associations with ACE genotype may be due to functional variants in nearby loci, and/or related genetic polymorphism such as the angiotensin receptor, growth hormone and bradykinin genes. Studies of growth hormone gene variants have not shown significant associations with performance in studies involving both triathletes and military recruits. The angiotensin type-1 receptor has two functional polymorphisms that have not been shown to be associated with performance, although studies of hypoxic ascent have yielded conflicting results. ACE genotype influences bradykinin levels, and a common gene variant in the bradykinin 2 receptor exists. The high kinin activity haplotye has been associated with increased endurance performance at an Olympic level, and similar results of metabolic efficiency have been demonstrated in triathletes. Whilst the ACE genotype is associated with overall performance ability, at a single organ level, the ACE genotype and related polymorphism have significant

  13. Decay correction methods in dynamic PET studies

    International Nuclear Information System (INIS)

    Chen, K.; Reiman, E.; Lawson, M.

    1995-01-01

    In order to reconstruct positron emission tomography (PET) images in quantitative dynamic studies, the data must be corrected for radioactive decay. One of the two commonly used methods ignores physiological processes including blood flow that occur at the same time as radioactive decay; the other makes incorrect use of time-accumulated PET counts. In simulated dynamic PET studies using 11 C-acetate and 18 F-fluorodeoxyglucose (FDG), these methods are shown to result in biased estimates of the time-activity curve (TAC) and model parameters. New methods described in this article provide significantly improved parameter estimates in dynamic PET studies

  14. SPAM-assisted partial volume correction algorithm for PET

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Sung Il; Kang, Keon Wook; Lee, Jae Sung; Lee, Dong Soo; Chung, June Key; Soh, Kwang Sup; Lee, Myung Chul [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    2000-07-01

    A probabilistic atlas of the human brain (Statistical Probability Anatomical Maps: SPAM) was developed by the International Consortium for Brain Mapping (ICBM). It will be a good frame for calculating volume of interest (VOI) according to statistical variability of human brain in many fields of brain images. We show that we can get more exact quantification of the counts in VOI by using SPAM in the correlation of partial volume effect for simulated PET image. The MRI of a patient with dementia was segmented into gray matter and white matter, and then they were smoothed to PET resolution. Simulated PET image was made by adding one third of the smoothed white matter to the smoothed gray matter. Spillover effect and partial volume effect were corrected for this simulated PET image with the aid of the segmented and smoothed MR images. The images were spatially normalized to the average brain MRI atlas of ICBM, and were multiplied by the probablities of 98 VOIs of SPAM images of Montreal Neurological Institute. After the correction of partial volume effect, the counts of frontal, partietal, temporal, and occipital lobes were increased by 38{+-}6%, while those of hippocampus and amygdala by 4{+-}3%. By calculating the counts in VOI using the product of probability of SPAM images and counts in the simulated PET image, the counts increase and become closer to the true values. SPAM-assisted partial volume correction is useful for quantification of VOIs in PET images.

  15. SPAM-assisted partial volume correction algorithm for PET

    International Nuclear Information System (INIS)

    Cho, Sung Il; Kang, Keon Wook; Lee, Jae Sung; Lee, Dong Soo; Chung, June Key; Soh, Kwang Sup; Lee, Myung Chul

    2000-01-01

    A probabilistic atlas of the human brain (Statistical Probability Anatomical Maps: SPAM) was developed by the International Consortium for Brain Mapping (ICBM). It will be a good frame for calculating volume of interest (VOI) according to statistical variability of human brain in many fields of brain images. We show that we can get more exact quantification of the counts in VOI by using SPAM in the correlation of partial volume effect for simulated PET image. The MRI of a patient with dementia was segmented into gray matter and white matter, and then they were smoothed to PET resolution. Simulated PET image was made by adding one third of the smoothed white matter to the smoothed gray matter. Spillover effect and partial volume effect were corrected for this simulated PET image with the aid of the segmented and smoothed MR images. The images were spatially normalized to the average brain MRI atlas of ICBM, and were multiplied by the probablities of 98 VOIs of SPAM images of Montreal Neurological Institute. After the correction of partial volume effect, the counts of frontal, partietal, temporal, and occipital lobes were increased by 38±6%, while those of hippocampus and amygdala by 4±3%. By calculating the counts in VOI using the product of probability of SPAM images and counts in the simulated PET image, the counts increase and become closer to the true values. SPAM-assisted partial volume correction is useful for quantification of VOIs in PET images

  16. Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques.

    Science.gov (United States)

    Hofmann, Matthias; Pichler, Bernd; Schölkopf, Bernhard; Beyer, Thomas

    2009-03-01

    Positron emission tomography (PET) is a fully quantitative technology for imaging metabolic pathways and dynamic processes in vivo. Attenuation correction of raw PET data is a prerequisite for quantification and is typically based on separate transmission measurements. In PET/CT attenuation correction, however, is performed routinely based on the available CT transmission data. Recently, combined PET/magnetic resonance (MR) has been proposed as a viable alternative to PET/CT. Current concepts of PET/MRI do not include CT-like transmission sources and, therefore, alternative methods of PET attenuation correction must be found. This article reviews existing approaches to MR-based attenuation correction (MR-AC). Most groups have proposed MR-AC algorithms for brain PET studies and more recently also for torso PET/MR imaging. Most MR-AC strategies require the use of complementary MR and transmission images, or morphology templates generated from transmission images. We review and discuss these algorithms and point out challenges for using MR-AC in clinical routine. MR-AC is work-in-progress with potentially promising results from a template-based approach applicable to both brain and torso imaging. While efforts are ongoing in making clinically viable MR-AC fully automatic, further studies are required to realize the potential benefits of MR-based motion compensation and partial volume correction of the PET data.

  17. Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques

    International Nuclear Information System (INIS)

    Hofmann, Matthias; Pichler, Bernd; Schoelkopf, Bernhard; Beyer, Thomas

    2009-01-01

    Positron emission tomography (PET) is a fully quantitative technology for imaging metabolic pathways and dynamic processes in vivo. Attenuation correction of raw PET data is a prerequisite for quantification and is typically based on separate transmission measurements. In PET/CT attenuation correction, however, is performed routinely based on the available CT transmission data. Recently, combined PET/magnetic resonance (MR) has been proposed as a viable alternative to PET/CT. Current concepts of PET/MRI do not include CT-like transmission sources and, therefore, alternative methods of PET attenuation correction must be found. This article reviews existing approaches to MR-based attenuation correction (MR-AC). Most groups have proposed MR-AC algorithms for brain PET studies and more recently also for torso PET/MR imaging. Most MR-AC strategies require the use of complementary MR and transmission images, or morphology templates generated from transmission images. We review and discuss these algorithms and point out challenges for using MR-AC in clinical routine. MR-AC is work-in-progress with potentially promising results from a template-based approach applicable to both brain and torso imaging. While efforts are ongoing in making clinically viable MR-AC fully automatic, further studies are required to realize the potential benefits of MR-based motion compensation and partial volume correction of the PET data. (orig.)

  18. Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, Matthias [Max Planck Institute for Biological Cybernetics, Tuebingen (Germany); University of Tuebingen, Laboratory for Preclinical Imaging and Imaging Technology of the Werner Siemens-Foundation, Department of Radiology, Tuebingen (Germany); University of Oxford, Wolfson Medical Vision Laboratory, Department of Engineering Science, Oxford (United Kingdom); Pichler, Bernd [University of Tuebingen, Laboratory for Preclinical Imaging and Imaging Technology of the Werner Siemens-Foundation, Department of Radiology, Tuebingen (Germany); Schoelkopf, Bernhard [Max Planck Institute for Biological Cybernetics, Tuebingen (Germany); Beyer, Thomas [University Hospital Duisburg-Essen, Department of Nuclear Medicine, Essen (Germany); Cmi-Experts GmbH, Zurich (Switzerland)

    2009-03-15

    Positron emission tomography (PET) is a fully quantitative technology for imaging metabolic pathways and dynamic processes in vivo. Attenuation correction of raw PET data is a prerequisite for quantification and is typically based on separate transmission measurements. In PET/CT attenuation correction, however, is performed routinely based on the available CT transmission data. Recently, combined PET/magnetic resonance (MR) has been proposed as a viable alternative to PET/CT. Current concepts of PET/MRI do not include CT-like transmission sources and, therefore, alternative methods of PET attenuation correction must be found. This article reviews existing approaches to MR-based attenuation correction (MR-AC). Most groups have proposed MR-AC algorithms for brain PET studies and more recently also for torso PET/MR imaging. Most MR-AC strategies require the use of complementary MR and transmission images, or morphology templates generated from transmission images. We review and discuss these algorithms and point out challenges for using MR-AC in clinical routine. MR-AC is work-in-progress with potentially promising results from a template-based approach applicable to both brain and torso imaging. While efforts are ongoing in making clinically viable MR-AC fully automatic, further studies are required to realize the potential benefits of MR-based motion compensation and partial volume correction of the PET data. (orig.)

  19. Angiotensin I - Converting Enzyme (ACE) gene polymorphism in relation to physical performance, cognition and survival

    DEFF Research Database (Denmark)

    Frederiksen, Henrik; Gaist, David; Bathum, Lise

    2003-01-01

    Studies of younger individuals have suggested an association between ACE genotype and physical and cognitive performance. Using a longitudinal study of elderly twins we studied the association between ACE genotype and physical and cognitive functioning and survival in old age.......Studies of younger individuals have suggested an association between ACE genotype and physical and cognitive performance. Using a longitudinal study of elderly twins we studied the association between ACE genotype and physical and cognitive functioning and survival in old age....

  20. Association of angiotensin-converting enzyme (ACE) gene polymorphism with elevated serum ACE activity and major depression in an Iranian population.

    Science.gov (United States)

    Firouzabadi, Negar; Shafiei, Massoumeh; Bahramali, Ehsan; Ebrahimi, Soltan Ahmed; Bakhshandeh, Hooman; Tajik, Nader

    2012-12-30

    Genetic factors contribute substantially to the likelihood of developing major depressive disorder (MDD). The importance of renin-angiotensin system (RAS) elements in cognition and behaviour and their involvement in aetiology and treatment of depression imply that RAS gene polymorphism(s) associated with RAS overactivity might also be associated with depression. In the present study, genotype and allele frequencies of six common polymorphisms of genes encoding for RAS components were determined in DNAs extracted from venous blood of 191 depressed and 104 healthy individuals using polymerase chain reaction (PCR) and polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) and serum angiotensin-converting enzyme (ACE) activity was assayed using a high-performance liquid chromatography (HPLC) method. The results showed, for the first time, that GG genotype of ACE A2350G was significantly associated with MDD among Iranian participants (P=0.001; odds ratio (OR)=6.2; 95% confidence interval (CI)=2.1-18.3). Significant higher serum ACE activity (P=0.0001) as well as higher diastolic blood pressure (P=0.036) were observed in depressed patients compared to the healthy control group. Depressed patients carrying GG genotype of the A2350G polymorphism had a significantly higher serum ACE activity (P=0.02) than individuals with either AA or AG genotype. In conclusion, this study supports the hypothesis of RAS overactivity in depression in that the genotype associated with higher serum ACE activity in an Iranian population was also associated with MDD. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  1. PET/CT with intravenous contrast can be used for PET attenuation correction in cancer patients

    DEFF Research Database (Denmark)

    Berthelsen, A K; Holm, S; Loft, A

    2005-01-01

    PURPOSE: If the CT scan of a combined PET/CT study is performed as a full diagnostic quality CT scan including intravenous (IV) contrast agent, the quality of the joint PET/CT procedure is improved and a separate diagnostic CT scan can be avoided. CT with IV contrast can be used for PET attenuation...... correction, but this may result in a bias in the attenuation factors. The clinical significance of this bias has not been established. Our aim was to perform a prospective clinical study where each patient had CT performed with and without IV contrast agent to establish whether PET/CT with IV contrast can...... scans without, and then with contrast agent, followed by an 18F-fluorodeoxyglucose whole-body PET scan. The CT examinations were performed with identical parameters on a GE Discovery LS scanner. The PET data were reconstructed with attenuation correction based on the two CT data sets. A global...

  2. Seroprevalence and genotype of Chlamydia in pet parrots in China.

    Science.gov (United States)

    Zhang, N-Z; Zhang, X-X; Zhou, D-H; Huang, S-Y; Tian, W-P; Yang, Y-C; Zhao, Q; Zhu, X-Q

    2015-01-01

    Parrots are one of the most popular pet birds in China, and can harbour Chlamydia which has significance for human and animal health. We investigated, by indirect haemagglutination assay, the seroprevalence of Chlamydia infection in four species of parrots, namely budgerigars (Melopsittacus undulatus), lovebirds (Agapornis sp.), cockatiels (Nymphicus hollandicus) and Alexandrine parakeets (Psittacula eupatria) that were collected from Weifang and Beijing cities, North China and explored the association between potential risk factors and chlamydial seropositivity. We further determined the genotype of Chlamydia in 21 fresh faecal samples based on the ompA sequence by reconstruction of phylogenetic relationships. Of the 311 parrots examined, 35·37% (95% confidence interval 30·06-40·68) were seropositive, and species, gender, age, season and geographical location were identified as risk factors. Two PCR-positive samples represented Chlamydia psittaci genotype A. The occurrence of C. psittaci genotype A in the droppings of two pet parrots in China suggests potential environmental contamination with Chlamydiaceae and may raise a public health concern.

  3. MR Imaging-Guided Attenuation Correction of PET Data in PET/MR Imaging.

    Science.gov (United States)

    Izquierdo-Garcia, David; Catana, Ciprian

    2016-04-01

    Attenuation correction (AC) is one of the most important challenges in the recently introduced combined PET/magnetic resonance (MR) scanners. PET/MR AC (MR-AC) approaches aim to develop methods that allow accurate estimation of the linear attenuation coefficients of the tissues and other components located in the PET field of view. MR-AC methods can be divided into 3 categories: segmentation, atlas, and PET based. This review provides a comprehensive list of the state-of-the-art MR-AC approaches and their pros and cons. The main sources of artifacts are presented. Finally, this review discusses the current status of MR-AC approaches for clinical applications. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Simultaneous PET-MR acquisition and MR-derived motion fields for correction of non-rigid motion in PET

    International Nuclear Information System (INIS)

    Tsoumpas, C.; Mackewn, J.E.; Halsted, P.; King, A.P.; Buerger, C.; Totman, J.J.; Schaeffter, T.; Marsden, P.K.

    2010-01-01

    Positron emission tomography (PET) provides an accurate measurement of radiotracer concentration in vivo, but performance can be limited by subject motion which degrades spatial resolution and quantitative accuracy. This effect may become a limiting factor for PET studies in the body as PET scanner technology improves. In this work, we propose a new approach to address this problem by employing motion information from images measured simultaneously using a magnetic resonance (MR) scanner. The approach is demonstrated using an MR-compatible PET scanner and PET-MR acquisition with a purpose-designed phantom capable of non-rigid deformations. Measured, simultaneously acquired MR data were used to correct for motion in PET, and results were compared with those obtained using motion information from PET images alone. Motion artefacts were significantly reduced and the PET image quality and quantification was significantly improved by the use of MR motion fields, whilst the use of PET-only motion information was less successful. Combined PET-MR acquisitions potentially allow PET motion compensation in whole-body acquisitions without prolonging PET acquisition time or increasing radiation dose. This, to the best of our knowledge, is the first study to demonstrate that simultaneously acquired MR data can be used to estimate and correct for the effects of non-rigid motion in PET. (author)

  5. MR-assisted PET Motion Correction for eurological Studies in an Integrated MR-PET Scanner

    Science.gov (United States)

    Catana, Ciprian; Benner, Thomas; van der Kouwe, Andre; Byars, Larry; Hamm, Michael; Chonde, Daniel B.; Michel, Christian J.; El Fakhri, Georges; Schmand, Matthias; Sorensen, A. Gregory

    2011-01-01

    Head motion is difficult to avoid in long PET studies, degrading the image quality and offsetting the benefit of using a high-resolution scanner. As a potential solution in an integrated MR-PET scanner, the simultaneously acquired MR data can be used for motion tracking. In this work, a novel data processing and rigid-body motion correction (MC) algorithm for the MR-compatible BrainPET prototype scanner is described and proof-of-principle phantom and human studies are presented. Methods To account for motion, the PET prompts and randoms coincidences as well as the sensitivity data are processed in the line or response (LOR) space according to the MR-derived motion estimates. After sinogram space rebinning, the corrected data are summed and the motion corrected PET volume is reconstructed from these sinograms and the attenuation and scatter sinograms in the reference position. The accuracy of the MC algorithm was first tested using a Hoffman phantom. Next, human volunteer studies were performed and motion estimates were obtained using two high temporal resolution MR-based motion tracking techniques. Results After accounting for the physical mismatch between the two scanners, perfectly co-registered MR and PET volumes are reproducibly obtained. The MR output gates inserted in to the PET list-mode allow the temporal correlation of the two data sets within 0.2 s. The Hoffman phantom volume reconstructed processing the PET data in the LOR space was similar to the one obtained processing the data using the standard methods and applying the MC in the image space, demonstrating the quantitative accuracy of the novel MC algorithm. In human volunteer studies, motion estimates were obtained from echo planar imaging and cloverleaf navigator sequences every 3 seconds and 20 ms, respectively. Substantially improved PET images with excellent delineation of specific brain structures were obtained after applying the MC using these MR-based estimates. Conclusion A novel MR-based MC

  6. Multi-atlas attenuation correction supports full quantification of static and dynamic brain PET data in PET-MR

    Science.gov (United States)

    Mérida, Inés; Reilhac, Anthonin; Redouté, Jérôme; Heckemann, Rolf A.; Costes, Nicolas; Hammers, Alexander

    2017-04-01

    In simultaneous PET-MR, attenuation maps are not directly available. Essential for absolute radioactivity quantification, they need to be derived from MR or PET data to correct for gamma photon attenuation by the imaged object. We evaluate a multi-atlas attenuation correction method for brain imaging (MaxProb) on static [18F]FDG PET and, for the first time, on dynamic PET, using the serotoninergic tracer [18F]MPPF. A database of 40 MR/CT image pairs (atlases) was used. The MaxProb method synthesises subject-specific pseudo-CTs by registering each atlas to the target subject space. Atlas CT intensities are then fused via label propagation and majority voting. Here, we compared these pseudo-CTs with the real CTs in a leave-one-out design, contrasting the MaxProb approach with a simplified single-atlas method (SingleAtlas). We evaluated the impact of pseudo-CT accuracy on reconstructed PET images, compared to PET data reconstructed with real CT, at the regional and voxel levels for the following: radioactivity images; time-activity curves; and kinetic parameters (non-displaceable binding potential, BPND). On static [18F]FDG, the mean bias for MaxProb ranged between 0 and 1% for 73 out of 84 regions assessed, and exceptionally peaked at 2.5% for only one region. Statistical parametric map analysis of MaxProb-corrected PET data showed significant differences in less than 0.02% of the brain volume, whereas SingleAtlas-corrected data showed significant differences in 20% of the brain volume. On dynamic [18F]MPPF, most regional errors on BPND ranged from -1 to  +3% (maximum bias 5%) for the MaxProb method. With SingleAtlas, errors were larger and had higher variability in most regions. PET quantification bias increased over the duration of the dynamic scan for SingleAtlas, but not for MaxProb. We show that this effect is due to the interaction of the spatial tracer-distribution heterogeneity variation over time with the degree of accuracy of the attenuation maps. This

  7. PET/CT with intravenous contrast can be used for PET attenuation correction in cancer patients

    International Nuclear Information System (INIS)

    Berthelsen, A.K.; Holm, S.; Loft, A.; Klausen, T.L.; Andersen, F.; Hoejgaard, L.

    2005-01-01

    If the CT scan of a combined PET/CT study is performed as a full diagnostic quality CT scan including intravenous (IV) contrast agent, the quality of the joint PET/CT procedure is improved and a separate diagnostic CT scan can be avoided. CT with IV contrast can be used for PET attenuation correction, but this may result in a bias in the attenuation factors. The clinical significance of this bias has not been established. Our aim was to perform a prospective clinical study where each patient had CT performed with and without IV contrast agent to establish whether PET/CT with IV contrast can be used for PET attenuation without reducing the clinical value of the PET scan. A uniform phantom study was used to document that the PET acquisition itself is not significantly influenced by the presence of IV contrast medium. Then, 19 patients referred to PET/CT with IV contrast underwent CT scans without, and then with contrast agent, followed by an 18 F-fluorodeoxyglucose whole-body PET scan. The CT examinations were performed with identical parameters on a GE Discovery LS scanner. The PET data were reconstructed with attenuation correction based on the two CT data sets. A global comparison of standard uptake value (SUV) was performed, and SUVs in tumour, in non-tumour tissue and in the subclavian vein were calculated. Clinical evaluation of the number and location of lesions on all PET/CT scans was performed twice, blinded and in a different random order, by two independent nuclear medicine specialists. In all patients, the measured global SUV of PET images based on CT with IV contrast agent was higher than the global activity using non-contrast correction. The overall increase in the mean SUV (for two different conversion tables tested) was 4.5±2.3% and 1.6±0.5%, respectively. In 11/19 patients, focal uptake was identified corresponding to malignant tumours. Eight out of 11 tumours showed an increased SUV max (2.9±3.1%) on the PET images reconstructed using IV contrast

  8. Respiratory and cardiac motion correction in dual gated PET/MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fayad, Hadi; Monnier, Florian [LaTIM, INSERM, UMR 1101, Brest (France); Odille, Freedy; Felblinger, Jacques [INSERM U947, University of Nancy, Nancy (France); Lamare, Frederic [INCIA, UMR5287, CNRS, CHU Bordeaux, Bordeaux (France); Visvikis, Dimitris [LaTIM, INSERM, UMR 1101, Brest (France)

    2015-05-18

    Respiratory and cardiac motion in PET/MR imaging leads to reduced quantitative and qualitative image accuracy. Correction methodologies involve the use of double gated acquisitions which lead to low signal-to-noise ratio (SNR) and to issues concerning the combination of cardiac and respiratory frames. The objective of this work is to use a generalized reconstruction by inversion of coupled systems (GRICS) approach, previously used for PET/MR respiratory motion correction, combined with a cardiac phase signal and a reconstruction incorporated PET motion correction approach in order to reconstruct motion free images from dual gated PET acquisitions. The GRICS method consists of formulating parallel MRI in the presence of patient motion as a coupled inverse problem. Its resolution, using a fixed-point method, allows the reconstructed image to be improved using a motion model constructed from the raw MR data and two respiratory belts. GRICS obtained respiratory displacements are interpolated using the cardiac phase derived from an ECG to model simultaneous cardiac and respiratory motion. Three different volunteer datasets (4DMR acquisitions) were used for evaluation. GATE was used to simulate 4DPET datasets corresponding to the acquired 4DMR images. Simulated data were subsequently binned using 16 cardiac phases (M1) vs diastole only (M2), in combination with 8 respiratory amplitude gates. Respiratory and cardiac motion corrected PET images using either M1 or M2 were compared to respiratory only corrected images and evaluated in terms of SNR and contrast improvement. Significant visual improvements were obtained when correcting simultaneously for respiratory and cardiac motion (using 16 cardiac phase or diastole only) compared to respiratory motion only compensation. Results were confirmed by an associated increased SNR and contrast. Results indicate that using GRICS is an efficient tool for respiratory and cardiac motion correction in dual gated PET/MR imaging.

  9. Motion correction options in PET/MRI.

    Science.gov (United States)

    Catana, Ciprian

    2015-05-01

    Subject motion is unavoidable in clinical and research imaging studies. Breathing is the most important source of motion in whole-body PET and MRI studies, affecting not only thoracic organs but also those in the upper and even lower abdomen. The motion related to the pumping action of the heart is obviously relevant in high-resolution cardiac studies. These two sources of motion are periodic and predictable, at least to a first approximation, which means certain techniques can be used to control the motion (eg, by acquiring the data when the organ of interest is relatively at rest). Additionally, nonperiodic and unpredictable motion can also occur during the scan. One obvious limitation of methods relying on external devices (eg, respiratory bellows or the electrocardiogram signal to monitor the respiratory or cardiac cycle, respectively) to trigger or gate the data acquisition is that the complex motion of internal organs cannot be fully characterized. However, detailed information can be obtained using either the PET or MRI data (or both) allowing the more complete characterization of the motion field so that a motion model can be built. Such a model and the information derived from simple external devices can be used to minimize the effects of motion on the collected data. In the ideal case, all the events recorded during the PET scan would be used to generate a motion-free or corrected PET image. The detailed motion field can be used for this purpose by applying it to the PET data before, during, or after the image reconstruction. Integrating all these methods for motion control, characterization, and correction into a workflow that can be used for routine clinical studies is challenging but could potentially be extremely valuable given the improvement in image quality and reduction of motion-related image artifacts. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Variation in the ACE, PPARGC1A and PPARA genes in Lithuanian football players.

    Science.gov (United States)

    Gineviciene, Valentina; Jakaitiene, Audrone; Tubelis, Linas; Kucinskas, Vaidutis

    2014-01-01

    The aim of this study was to determine the impact of ACE (I/D), PPARGC1A (G/A) and PPARA (G/C) polymorphisms on footballers performance among 199 Lithuanian professional footballers and 167 sedentary, healthy men (controls). Genotyping was performed using polymerase chain reaction and restriction fragment length polymorphism methods on DNA from leucocytes. Results revealed that the angiotensin-1-coverting enzyme gene (ACE) genotype distribution was significantly different between total football players group (II 23.6%, ID 46.7% and DD 29.6%) and the controls (II 24.6%, ID 29.9% and DD 45.5%; P=0.002). Although investigating PPARGC1A (G/A) and PPARA (G/C) polymorphisms no significant results were obtained in the total football players group, however, significant differences were determined between forwards and controls [PPARGC1A: GG 54.6%, GA 29.5%, AA 15.9% vs. GG 49.7%, GA 44.3% and AA 6.0% (P = 0.044); PPARA: GG 52.3%, GC 40.9%, CC 6.8% vs. GG 72.4%, GC 24.6% and CC 3.0% (P = 0.034)]. In the whole cohort, the odds ratio of the genotype [ACE ID + PPARA GG] being a footballer was 1.69 (95% CI 1.04-2.74), and of [ACE ID + PPARGC1A GG] 1.93 (95% CI 1.10-3.37) and of [ACE II + PPARA GC] 2.83 (95% CI 1.02-7.91) compared to controls. It was revealed that ACE ID genotype together with PPARA GG and PPARGC1A GG as well as ACE II genotype with PPARA GC is probably the 'preferable genotype' for footballers. Summing up, the present study suggests that the ACE, PPARGC1A and PPARA polymorphisms genotypes are associated, separately and in combination, with Lithuanian footballers' performance.

  11. Wavelet-based partial volume effect correction for simultaneous MR/PET of the carotid arteries

    International Nuclear Information System (INIS)

    Bini, Jason; Eldib, Mootaz; Robson, Philip M; Fayad, Zahi A

    2014-01-01

    Simultaneous MR/PET scanners allow for the exploration and development of novel PVE correction techniques without the challenges of coregistration of MR and PET. The development of a wavelet-based PVE correction method, to improve PET quantification, has proven successful in brain PET. 2 We report here the first attempt to apply these methods to simultaneous MR/PET imaging of the carotid arteries.

  12. Evaluation of ACE gene I/D polymorphism in Iranian elite athletes.

    Science.gov (United States)

    Shahmoradi, Somayeh; Ahmadalipour, Ali; Salehi, Mansoor

    2014-01-01

    Angiotensin converting enzyme (ACE) is an important gene, which is associated with the successful physical activity. The ACE gene has a major polymorphism (I/D) in intron 16 that determines its plasma and tissue levels. In this study, we aimed to determine whether there is an association between this polymorphism and sports performance in our studied population including elite athletes of different sports disciplines. We investigated allele frequency and genotype distribution of the ACE gene in 156 Iranian elite athletes compared to 163 healthy individuals. We also investigated this allele frequency between elite athletes in three functional groups of endurance, power, and mixed sports performances. DNA was extracted from peripheral blood, and polymerase chain reaction (PCR) method was performed on intron 16 of the ACE gene. The ACE genotype was determined for each subject. Statistical analysis was performed by SPSS 15, and results were analyzed by Chi-Square test. There was a significant difference in genotype distribution and allele frequency of the ACE gene in athletes and control group (P = 0.05, P = 0.03, respectively). There was also a significant difference in allele frequency of the ACE gene in 3 groups of athletes with different sports disciplines (P = 0.045). Proportion of the ACE gene D allele was greater in elite endurance athletes (37 high-distance cyclists) than two other groups. Findings of the present study demonstrated that there is an association between the ACE gene I/D polymorphism and sports performance in Iranian elite athletes.

  13. Non rigid respiratory motion correction in whole body PET/MR imaging

    International Nuclear Information System (INIS)

    Fayad, Hadi; Schmidt, Holger; Wuerslin, Christian; Visvikis, Dimitris

    2014-01-01

    Respiratory motion in PET/MR imaging leads to reduced quantitative and qualitative image accuracy. Correction methodologies include the use of respiratory synchronized gated frames which lead to low signal to noise ratio (SNR) given that each frame contains only part of the count available throughout an average PET acquisition. In this work, 4D MRI extracted elastic transformations were applied to list-mode data either inside the image reconstruction or to the reconstructed respiratory synchronized images to obtain respiration corrected PET images.

  14. MR-assisted PET motion correction in simultaneous PET/MRI studies of dementia subjects.

    Science.gov (United States)

    Chen, Kevin T; Salcedo, Stephanie; Chonde, Daniel B; Izquierdo-Garcia, David; Levine, Michael A; Price, Julie C; Dickerson, Bradford C; Catana, Ciprian

    2018-03-08

    Subject motion in positron emission tomography (PET) studies leads to image blurring and artifacts; simultaneously acquired magnetic resonance imaging (MRI) data provides a means for motion correction (MC) in integrated PET/MRI scanners. To assess the effect of realistic head motion and MR-based MC on static [ 18 F]-fluorodeoxyglucose (FDG) PET images in dementia patients. Observational study. Thirty dementia subjects were recruited. 3T hybrid PET/MR scanner where EPI-based and T 1 -weighted sequences were acquired simultaneously with the PET data. Head motion parameters estimated from high temporal resolution MR volumes were used for PET MC. The MR-based MC method was compared to PET frame-based MC methods in which motion parameters were estimated by coregistering 5-minute frames before and after accounting for the attenuation-emission mismatch. The relative changes in standardized uptake value ratios (SUVRs) between the PET volumes processed with the various MC methods, without MC, and the PET volumes with simulated motion were compared in relevant brain regions. The absolute value of the regional SUVR relative change was assessed with pairwise paired t-tests testing at the P = 0.05 level, comparing the values obtained through different MR-based MC processing methods as well as across different motion groups. The intraregion voxelwise variability of regional SUVRs obtained through different MR-based MC processing methods was also assessed with pairwise paired t-tests testing at the P = 0.05 level. MC had a greater impact on PET data quantification in subjects with larger amplitude motion (higher than 18% in the medial orbitofrontal cortex) and greater changes were generally observed for the MR-based MC method compared to the frame-based methods. Furthermore, a mean relative change of ∼4% was observed after MC even at the group level, suggesting the importance of routinely applying this correction. The intraregion voxelwise variability of regional SUVRs

  15. Wavelet-based partial volume effect correction for simultaneous MR/PET of the carotid arteries

    Energy Technology Data Exchange (ETDEWEB)

    Bini, Jason; Eldib, Mootaz [Translational and Molecular Imaging Institute, Icahn School of Medicine at Mount Sinai, NY, NY (United States); Department of Biomedical Engineering, The City College of New York, NY, NY (United States); Robson, Philip M; Fayad, Zahi A [Translational and Molecular Imaging Institute, Icahn School of Medicine at Mount Sinai, NY, NY (United States)

    2014-07-29

    Simultaneous MR/PET scanners allow for the exploration and development of novel PVE correction techniques without the challenges of coregistration of MR and PET. The development of a wavelet-based PVE correction method, to improve PET quantification, has proven successful in brain PET.{sup 2} We report here the first attempt to apply these methods to simultaneous MR/PET imaging of the carotid arteries.

  16. Initial evaluation of a practical PET respiratory motion correction method in clinical simultaneous PET/MRI

    International Nuclear Information System (INIS)

    Manber, Richard; Thielemans, Kris; Hutton, Brian; Barnes, Anna; Ourselin, Sebastien; Arridge, Simon; O’Meara, Celia; Atkinson, David

    2014-01-01

    Respiratory motion during PET acquisitions can cause image artefacts, with sharpness and tracer quantification adversely affected due to count ‘smearing’. Motion correction by registration of PET gates becomes increasingly difficult with shorter scan times and less counts. The advent of simultaneous PET/MRI scanners allows the use of high spatial resolution MRI to capture motion states during respiration [1, 2]. In this work, we use a respiratory signal derived from the PET list-mode data [3, ], with no requirement for an external device or MR sequence modifications.

  17. Design of respiration averaged CT for attenuation correction of the PET data from PET/CT

    International Nuclear Information System (INIS)

    Chi, Pai-Chun Melinda; Mawlawi, Osama; Nehmeh, Sadek A.; Erdi, Yusuf E.; Balter, Peter A.; Luo, Dershan; Mohan, Radhe; Pan Tinsu

    2007-01-01

    Our previous patient studies have shown that the use of respiration averaged computed tomography (ACT) for attenuation correction of the positron emission tomography (PET) data from PET/CT reduces the potential misalignment in the thorax region by matching the temporal resolution of the CT to that of the PET. In the present work, we investigated other approaches of acquiring ACT in order to reduce the CT dose and to improve the ease of clinical implementation. Four-dimensional CT (4DCT) data sets for ten patients (17 lung/esophageal tumors) were acquired in the thoracic region immediately after the routine PET/CT scan. For each patient, multiple sets of ACTs were generated based on both phase image averaging (phase approach) and fixed cine duration image averaging (cine approach). In the phase approach, the ACTs were calculated from CT images corresponding to the significant phases of the respiratory cycle: ACT 050phs from end-inspiration (0%) and end-expiration (50%), ACT 2070phs from mid-inspiration (20%) and mid-expiration (70%), ACT 4phs from 0%, 20%, 50% and 70%, and ACT 10phs from all ten phases, which was the original approach. In the cine approach, which does not require 4DCT, the ACTs were calculated based on the cine images from cine durations of 1 to 6 s at 1 s increments. PET emission data for each patient were attenuation corrected with each of the above mentioned ACTs and the tumor maximum standard uptake value (SUV max ), average SUV (SUV avg ), and tumor volume measurements were compared. Percent differences were calculated between PET data corrected with various ACTs and that corrected with ACT 10phs . In the phase approach, the ACT 10phs can be approximated by the ACT 4phs to within a mean percent difference of 2% in SUV and tumor volume measurements. In cine approach, ACT 10phs can be approximated to within a mean percent difference of 3% by ACTs computed from cine durations ≥3 s. Acquiring CT images only at the four significant phases for the

  18. Ultra-low dose CT attenuation correction for PET/CT

    International Nuclear Information System (INIS)

    Xia Ting; Kinahan, Paul E; Alessio, Adam M; De Man, Bruno; Manjeshwar, Ravindra; Asma, Evren

    2012-01-01

    A challenge for positron emission tomography/computed tomography (PET/CT) quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the currently available, lowest dose CT techniques, extended duration cine CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging. (paper)

  19. Ultra-low dose CT attenuation correction for PET/CT

    Science.gov (United States)

    Xia, Ting; Alessio, Adam M.; De Man, Bruno; Manjeshwar, Ravindra; Asma, Evren; Kinahan, Paul E.

    2012-01-01

    A challenge for PET/CT quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the currently-available, lowest dose CT techniques, extended duration CINE CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. Methods We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. Results CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. Conclusion When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging. PMID:22156174

  20. MR-guided data framing for PET motion correction in simultaneous MR–PET: A preliminary evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Ullisch, M.G., E-mail: m.ullisch@fz-juelich.de [Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH (Germany); Scheins, J.; Weirich, C.; Rota Kops, E.; Celik, A.; Tellmann, L.; Stöcker, T.; Herzog, H.; Shah, N.J. [Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH (Germany)

    2013-02-21

    Head motion can significantly degrade image quality of static and dynamic Positron Emission Tomography (PET) of the human brain. One method to regain acceptable image quality in the presence of motion is to include the correction for motion in the reconstruction process. When applying motion correction, the PET data can be segmented into discrete parts of similar head position, referred to as frames. This framing of the data can reduce the computational overhead necessary for motion correction during the reconstruction process by reducing the number of discrete head positions which have to be accounted for. Here a framing algorithm is presented which minimises residual motion in the framed data, while taking full advantage of the additional information provided by Magnetic Resonance Imaging (MRI) in a simultaneous MR–PET acquisition. In the work presented here information on motion is derived from EPI sequences acquired simultaneously with the PET data. A comparison to images reconstructed with regular framing show a more clearly delineated cortex due to increased contrast between grey matter and white matter. This improvement in image quality is achieved as well as a reduction in the number of frames, thereby reducing the reconstruction time. Preliminary data indicates an efficient reduction of residual intra-frame motion compared to regular framing.

  1. Association of Angiotensin-Converting Enzyme (ACE Gene Polymorphism with Inflammation and Cellular Cytotoxicity in Vitiligo Patients.

    Directory of Open Access Journals (Sweden)

    Laila Rashed

    Full Text Available Vitiligo is a disorder with profound heterogeneity in its aetio-pathophysiology. Angiotensin converting enzyme (ACE plays an important role in the physiology of the vasculature, blood pressure and inflammation. An insertion/deletion (I/D polymorphism of the ACE gene was reported be associated with the development of vitiligo.Our aim was to evaluate the ACE I/D polymorphism in vitiligo patients and controls. Our second aim was to find a possible association between ACE gene polymorphism and inflammatory mediators (as interleukin (IL-6 and/or cellular cytotoxicity induced by serum nitrite (as a breakdown product of the cytotoxic nitric oxide in vitiligo patients.This case-control study included 74 vitiligo patients and 75 apparently healthy controls. The distribution of ACE gene I/D genotype was investigated using PCR. Serum ACE, IL-6 and nitrite were measured by colorimetric method, ELISA and Griess assay respectively.The ACE allele frequency was significantly different between vitiligo patients and healthy controls (P = 0.026. However there was no significant difference between the ACE genotyping frequency in both groups (P = 0.115. There were statistically significant higher VIDA score (P = 0.007, and serum IL-6 (P < 0.001 in patients with the DD genotype when compared to other genotypes. Serum nitrite in patients with the DD genotype was significantly higher (P = 0.007 when compared to patients with II genotype. Serum levels of ACE, IL-6 and nitrite in vitiligo patients were statistically significantly higher than those in controls.As a conclusion, ACE gene polymorphism might grant susceptibility to develop vitiligo. Serum IL-6 and nitrite levels might have an important role in the pathogenesis of vitiligo. Targeting these two factors might have an implication in the treatment of some resistant cases.

  2. Bias atlases for segmentation-based PET attenuation correction using PET-CT and MR.

    Science.gov (United States)

    Ouyang, Jinsong; Chun, Se Young; Petibon, Yoann; Bonab, Ali A; Alpert, Nathaniel; Fakhri, Georges El

    2013-10-01

    This study was to obtain voxel-wise PET accuracy and precision using tissue-segmentation for attenuation correction. We applied multiple thresholds to the CTs of 23 patients to classify tissues. For six of the 23 patients, MR images were also acquired. The MR fat/in-phase ratio images were used for fat segmentation. Segmented tissue classes were used to create attenuation maps, which were used for attenuation correction in PET reconstruction. PET bias images were then computed using the PET reconstructed with the original CT as the reference. We registered the CTs for all the patients and transformed the corresponding bias images accordingly. We then obtained the mean and standard deviation bias atlas using all the registered bias images. Our CT-based study shows that four-class segmentation (air, lungs, fat, other tissues), which is available on most PET-MR scanners, yields 15.1%, 4.1%, 6.6%, and 12.9% RMSE bias in lungs, fat, non-fat soft-tissues, and bones, respectively. An accurate fat identification is achievable using fat/in-phase MR images. Furthermore, we have found that three-class segmentation (air, lungs, other tissues) yields less than 5% standard deviation of bias within the heart, liver, and kidneys. This implies that three-class segmentation can be sufficient to achieve small variation of bias for imaging these three organs. Finally, we have found that inter- and intra-patient lung density variations contribute almost equally to the overall standard deviation of bias within the lungs.

  3. ACE Gene in Egyptian Ischemic Stroke Patients.

    Science.gov (United States)

    Mostafa, Magdy A; El-Nabiel, Lobna M; Fahmy, Nagia Aly; Aref, Hany; Shreef, Edrees; Abd El-Tawab, Fathy; Abdulghany, Osama M

    2016-09-01

    Angiotensin-1-converting enzyme (ACE) is a crucial player in vascular homeostasis and in the pathogenesis of atherosclerosis and hypertension. The present study was conducted to determine whether there is an association between the ACE insertion/deletion (I/D) polymorphism and ischemic stroke in Egyptian population. Also, we analyzed the ACE gene I/D polymorphism as a risk factor for small-vessel (SV) versus large-vessel (LV) disease. Sixty patients with ischemic stroke were included: 30 with SV disease and 30 with LV disease. In addition, a control group of 30 apparent healthy subjects were studied. Clinical assessment, computed tomography, magnetic resonance imaging brain, and genetic study using the polymerase chain reaction of ACE gene were done for all subjects. We found that the distribution of ACE gene polymorphism frequency was significantly different between the 3 groups. The DD genotype was far more common in stroke patients compared to controls. It was also significantly more common in each of the patient groups compared to controls but rather similar in the 2 patient groups with SV and LV diseases. We found that the ACE gene deletion/deletion genotype is common in Egyptian patients with non-cardioembolic ischemic stroke but does not appear to be specific neither to SV nor to LV disease. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  4. Evaluation of coronary blood flow reserve by 13N-NH3 positron emission computed tomography (PET) with dipyridamole in the treatment of hypertension with the ACE inhibitor (Cilazapril)

    International Nuclear Information System (INIS)

    Masuda, Daisuke; Nohara, Ryuji; Tamaki, Nagara

    2000-01-01

    The purpose of this study was to evaluate the effect of treatment with an angiotensin-converting enzyme (ACE) inhibitor (Cilazapril) for early hypertensive patients in terms of coronary blood flow reserve evaluated by 13 NH 3 -positron emission tomography (PET). Before and after 12 weeks of ACE inhibitor treatment, 13 NH 3 -PET with dipyridamole provocation test was performed, and definite myocardial perfusion and coronary flow reserve (CFR) were calculated. Compared to our normal subjects previously reported (2.61±0.74), average coronary flow reserve was decreased (1.70±0.64 in hypertensive patients), and improved after treatment (1.77±0.52), but not significantly. Of 12 patients, five (42%) showed improved coronary flow reserve from 1.34 to 1.99 without a significant change in the resting flow. Only one patient (8%) showed deterioration after the ACE inhibitor treatment. The coronary vascular resistance (CVR) after ACE inhibitor treatment of the patients with CFR <2.0 decreased significantly compared with those with CFR ≥2.0 (p<0.03). These results indicate that hypertensive patients at the early stage show decreased coronary flow reserve despite having normal resting flow. Treatment with an ACE inhibitor (Cilazapril) for 12 weeks improved coronary flow reserve in 42% of our patients. The CVR of the patients with CFR <2.0 showed improvement compared to those with CFR ≥2.0. This result indicates that an ACE inhibitor (e.g., Cilazapril) should be one of the choices for improving CFR if hypertensive patients in early stage show signs of ischemia or diastolic dysfunction, which may be one of the sequels of reserve restriction. (author)

  5. Assessment of endothelial function and myocardial flow reserve using 15O-water PET without attenuation correction

    International Nuclear Information System (INIS)

    Tuffier, Stephane; Joubert, Michael; Bailliez, Alban; Legallois, Damien; Belin, Annette; Redonnet, Michel; Agostini, Denis; Manrique, Alain

    2016-01-01

    Myocardial blood flow (MBF) measurement using positron emission tomography (PET) from the washout rate of 15 O-water is theoretically independent of tissue attenuation. The aim of this study was to evaluate the impact of not using attenuation correction in the assessment of coronary endothelial function and myocardial flow reserve (MFR) using 15 O-water PET. We retrospectively processed 70 consecutive 15 O-water PET examinations obtained at rest and during cold pressor testing (CPT) in patients with dilated cardiomyopathy (n = 58), or at rest and during adenosine infusion in heart transplant recipients (n = 12). Data were reconstructed with attenuation correction (AC) and without attenuation correction (NAC) using filtered backprojection, and MBF was quantified using a single compartmental model. The agreement between AC and NAC data was assessed using Lin's concordance correlation coefficient followed by Bland-Altman plot analysis. Regarding endothelial function, NAC PET showed poor reproducibility and poor agreement with AC PET data. Conversely, NAC PET demonstrated high reproducibility and a strong agreement with AC PET for the assessment of MFR. Non-attenuation-corrected 15 O-water PET provided an accurate measurement of MFR compared to attenuation-corrected PET. However, non-attenuation-corrected PET data were less effective for the assessment of endothelial function using CPT in this population. (orig.)

  6. Markerless 3D Head Tracking for Motion Correction in High Resolution PET Brain Imaging

    DEFF Research Database (Denmark)

    Olesen, Oline Vinter

    relying on markers. Data-driven motion correction is problematic due to the physiological dynamics. Marker-based tracking is potentially unreliable, and it is extremely hard to validate when the tracking information is correct. The motion estimation is essential for proper motion correction of the PET......This thesis concerns application specific 3D head tracking. The purpose is to improve motion correction in position emission tomography (PET) brain imaging through development of markerless tracking. Currently, motion correction strategies are based on either the PET data itself or tracking devices...... images. Incorrect motion correction can in the worst cases result in wrong diagnosis or treatment. The evolution of a markerless custom-made structured light 3D surface tracking system is presented. The system is targeted at state-of-the-art high resolution dedicated brain PET scanners with a resolution...

  7. MRI-assisted PET motion correction for neurologic studies in an integrated MR-PET scanner.

    Science.gov (United States)

    Catana, Ciprian; Benner, Thomas; van der Kouwe, Andre; Byars, Larry; Hamm, Michael; Chonde, Daniel B; Michel, Christian J; El Fakhri, Georges; Schmand, Matthias; Sorensen, A Gregory

    2011-01-01

    Head motion is difficult to avoid in long PET studies, degrading the image quality and offsetting the benefit of using a high-resolution scanner. As a potential solution in an integrated MR-PET scanner, the simultaneously acquired MRI data can be used for motion tracking. In this work, a novel algorithm for data processing and rigid-body motion correction (MC) for the MRI-compatible BrainPET prototype scanner is described, and proof-of-principle phantom and human studies are presented. To account for motion, the PET prompt and random coincidences and sensitivity data for postnormalization were processed in the line-of-response (LOR) space according to the MRI-derived motion estimates. The processing time on the standard BrainPET workstation is approximately 16 s for each motion estimate. After rebinning in the sinogram space, the motion corrected data were summed, and the PET volume was reconstructed using the attenuation and scatter sinograms in the reference position. The accuracy of the MC algorithm was first tested using a Hoffman phantom. Next, human volunteer studies were performed, and motion estimates were obtained using 2 high-temporal-resolution MRI-based motion-tracking techniques. After accounting for the misalignment between the 2 scanners, perfectly coregistered MRI and PET volumes were reproducibly obtained. The MRI output gates inserted into the PET list-mode allow the temporal correlation of the 2 datasets within 0.2 ms. The Hoffman phantom volume reconstructed by processing the PET data in the LOR space was similar to the one obtained by processing the data using the standard methods and applying the MC in the image space, demonstrating the quantitative accuracy of the procedure. In human volunteer studies, motion estimates were obtained from echo planar imaging and cloverleaf navigator sequences every 3 s and 20 ms, respectively. Motion-deblurred PET images, with excellent delineation of specific brain structures, were obtained using these 2 MRI

  8. Standardised uptake values from PET/CT images: comparison with conventional attenuation-corrected PET

    International Nuclear Information System (INIS)

    Souvatzoglou, M.; Ziegler, S.I.; Martinez, M.J.; Dzewas, G.; Schwaiger, M.; Bengel, F.; Busch, R.

    2007-01-01

    In PET/CT, CT-derived attenuation factors may influence standardised uptake values (SUVs) in tumour lesions and organs when compared with stand-alone PET. Therefore, we compared PET/CT-derived SUVs intra-individually in various organs and tumour lesions with stand-alone PET-derived SUVs. Thirty-five patients with known or suspected cancer were prospectively included. Sixteen patients underwent FDG PET using an ECAT HR+scanner, and subsequently a second scan using a Biograph Sensation 16PET/CT scanner. Nineteen patients were scanned in the reverse order. All images were reconstructed with an iterative algorithm (OSEM). Suspected lesions were grouped as paradiaphragmatic versus distant from the diaphragm. Mean and maximum SUVs were also calculated for brain, lung, liver, spleen and vertebral bone. The attenuation coefficients (μ values) used for correction of emission data (bone, soft tissue, lung) in the two data sets were determined. A body phantom containing six hot spheres and one cold cylinder was measured using the same protocol as in patients. Forty-six lesions were identified. There was a significant correlation of maximum and mean SUVs derived from PET and PET/CT for 14 paradiaphragmatic lesions (r=0.97 respectively; p<0.001 respectively) and for 32 lesions located distant from the diaphragm (r=0.87 and r=0.89 respectively; p<0.001 respectively). No significant differences were observed in the SUVs calculated with PET and PET/CT in the lesions or in the organs. In the phantom, radioactivity concentration in spheres calculated from PET and from PET/CT correlated significantly (r=0.99; p<0.001). SUVs of cancer lesions and normal organs were comparable between PET and PET/CT, supporting the usefulness of PET/CT-derived SUVs for quantification of tumour metabolism. (orig.)

  9. Insertion/deletion polymorphism of ACE gene in females with peripartum cardiomyopathy: A case-control study.

    Science.gov (United States)

    Yaqoob, Irfan; Tramboo, Nisar A; Bhat, Irfan A; Pandith, Arshad; Beig, Jahangir R; Hafeez, Imran; Lone, Aijaz A; Shah, Tariq R; Samreen, Sumera

    The role of polymorphism of Angiotensin converting enzyme (ACE) gene and ACE activity in etiopathogenesis, prognosis, and many other clinical parameters in the various form of the cardiovascular disease has been established to some degree of certainty. The pathophysiology of Peripartum cardiomyopathy (PPCM) remains an area of active research. The main aim of our study was to see pattern of ACE- Insertion/Deletion (I/D) allele in PPCM and its implications on left ventricular performance indices. This single-center case-control study included 45 cases and 70 controls. The diagnosis of PPCM was established clinically and echocardiographically. ACE genotyping was done by polymerase chain reaction (PCR) method in all subjects. The II, ID, and DD genotype was present in 16, 18 and 11 of subjects with PPCM and 48, 19 and 3 of controls respectively. The odds ratio for ACE-II genotype in cases vs. controls was 0.253 (95% CI=0.114-0.558; p=0.007), for that of II genotype was 1.93 (95% CI=0.86-4.3; p=0.107) and for DD genotype was 7.225 (95% CI; 1.88-27.6; p=0.0039). Overall frequency of D allele in cases was significantly higher than controls (odds=4.25; 95% CI=2.01-6.7; p=0.0001). Moreover, ejection fraction, left ventricular volume and linear dimensions were worse in patients with DD genotype. ACE DD genotype and overall frequency of D allele is significantly higher in patients with PPCM. Also, the presence of DD genotype is associated with worse systolic performance indices measured echocardiographically. Copyright © 2017. Published by Elsevier B.V.

  10. PET/CT detectability and classification of simulated pulmonary lesions using an SUV correction scheme

    Science.gov (United States)

    Morrow, Andrew N.; Matthews, Kenneth L., II; Bujenovic, Steven

    2008-03-01

    Positron emission tomography (PET) and computed tomography (CT) together are a powerful diagnostic tool, but imperfect image quality allows false positive and false negative diagnoses to be made by any observer despite experience and training. This work investigates PET acquisition mode, reconstruction method and a standard uptake value (SUV) correction scheme on the classification of lesions as benign or malignant in PET/CT images, in an anthropomorphic phantom. The scheme accounts for partial volume effect (PVE) and PET resolution. The observer draws a region of interest (ROI) around the lesion using the CT dataset. A simulated homogenous PET lesion of the same shape as the drawn ROI is blurred with the point spread function (PSF) of the PET scanner to estimate the PVE, providing a scaling factor to produce a corrected SUV. Computer simulations showed that the accuracy of the corrected PET values depends on variations in the CT-drawn boundary and the position of the lesion with respect to the PET image matrix, especially for smaller lesions. Correction accuracy was affected slightly by mismatch of the simulation PSF and the actual scanner PSF. The receiver operating characteristic (ROC) study resulted in several observations. Using observer drawn ROIs, scaled tumor-background ratios (TBRs) more accurately represented actual TBRs than unscaled TBRs. For the PET images, 3D OSEM outperformed 2D OSEM, 3D OSEM outperformed 3D FBP, and 2D OSEM outperformed 2D FBP. The correction scheme significantly increased sensitivity and slightly increased accuracy for all acquisition and reconstruction modes at the cost of a small decrease in specificity.

  11. Comparison of the optimized conditions for genotyping of ACE ID ...

    African Journals Online (AJOL)

    ACE ID polymorphism is inevitable for genetic epidemiology of several cardiovascular and non cardiovascular diseases due to its direct influence on ACE activity level. In the present work, conditions were optimized for its analysis using conventional and direct blood PCR (DB PCR). Blood samples from nine normotensive ...

  12. Sources of attenuation-correction artefacts in cardiac PET/CT and SPECT/CT.

    Science.gov (United States)

    McQuaid, Sarah J; Hutton, Brian F

    2008-06-01

    Respiratory motion during myocardial perfusion imaging can cause artefacts in both positron emission tomography (PET) and single-photon emission computed tomography (SPECT) images when mismatches between emission and transmission datasets arise. In this study, artefacts from different breathing motions were quantified in both modalities to assess key factors in attenuation-correction accuracy. Activity maps were generated using the NURBS-based cardiac-torso phantom for different respiratory cycles, which were projected, attenuation-corrected and reconstructed to form PET and SPECT images. Attenuation-correction was performed with maps at mismatched respiratory phases to observe the effect on the left-ventricular myocardium. Myocardial non-uniformity was assessed in terms of the standard deviation in scores obtained from the 17-segment model and changes in uniformity were compared for each mismatch and modality. Certain types of mismatch led to artefacts and corresponding increases in the myocardial non-uniformity. For each mismatch in PET, the increases in non-uniformity relative to an artefact-free image were as follows: (a) cardiac translation mismatch, 84% +/- 11%; (b) liver mismatch, 59% +/- 10%, (c) lung mismatch from diaphragm contraction, 28% +/- 8%; and (d) lung mismatch from chest-wall motion, 6% +/- 7%. The corresponding factors for SPECT were (a) 61% +/- 8%, (b) 34% +/- 8%, (c) -2% +/- 7)% and (d) -4% +/- 6%. Attenuation-correction artefacts were seen in PET and SPECT images, with PET being more severely affected. The most severe artefacts were produced from mismatches in cardiac and liver position, whereas lung mismatches were less critical. Both cardiac and liver positions must, therefore, be correctly matched during attenuation correction.

  13. SU-F-I-59: Quality Assurance Phantom for PET/CT Alignment and Attenuation Correction

    International Nuclear Information System (INIS)

    Lin, T; Hamacher, K

    2016-01-01

    Purpose: This study utilizes a commercial PET/CT phantom to investigate two specific properties of a PET/CT system: the alignment accuracy of PET images with those from CT used for attenuation correction and the accuracy of this correction in PET images. Methods: A commercial PET/CT phantom consisting of three aluminum rods, two long central cylinders containing uniform activity, and attenuating materials such as air, water, bone and iodine contrast was scanned using a standard PET/CT protocol. Images reconstructed with 2 mm slice thickness and a 512 by 512 matrix were obtained. The center of each aluminum rod in the PET and CT images was compared to evaluate alignment accuracy. ROIs were drawn on transaxial images of the central rods at each section of attenuating material to determine the corrected activity (in BQML). BQML values were graphed as a function of slice number to provide a visual representation of the attenuation-correction throughout the whole phantom. Results: Alignment accuracy is high between the PET and CT images. The maximum deviation between the two in the axial plane is less than 1.5 mm, which is less than the width of a single pixel. BQML values measured along different sections of the large central rods are similar among the different attenuating materials except iodine contrast. Deviation of BQML values in the air and bone sections from the water section is less than 1%. Conclusion: Accurate alignment of PET and CT images is critical to ensure proper calculation and application of CT-based attenuation correction. This study presents a simple and quick method to evaluate the two with a single acquisition. As the phantom also includes spheres of increasing diameter, this could serve as a straightforward means to annually evaluate the status of a modern PET/CT system.

  14. SU-F-I-59: Quality Assurance Phantom for PET/CT Alignment and Attenuation Correction

    Energy Technology Data Exchange (ETDEWEB)

    Lin, T; Hamacher, K [Columbia University Medical Center, New York, NY (United States)

    2016-06-15

    Purpose: This study utilizes a commercial PET/CT phantom to investigate two specific properties of a PET/CT system: the alignment accuracy of PET images with those from CT used for attenuation correction and the accuracy of this correction in PET images. Methods: A commercial PET/CT phantom consisting of three aluminum rods, two long central cylinders containing uniform activity, and attenuating materials such as air, water, bone and iodine contrast was scanned using a standard PET/CT protocol. Images reconstructed with 2 mm slice thickness and a 512 by 512 matrix were obtained. The center of each aluminum rod in the PET and CT images was compared to evaluate alignment accuracy. ROIs were drawn on transaxial images of the central rods at each section of attenuating material to determine the corrected activity (in BQML). BQML values were graphed as a function of slice number to provide a visual representation of the attenuation-correction throughout the whole phantom. Results: Alignment accuracy is high between the PET and CT images. The maximum deviation between the two in the axial plane is less than 1.5 mm, which is less than the width of a single pixel. BQML values measured along different sections of the large central rods are similar among the different attenuating materials except iodine contrast. Deviation of BQML values in the air and bone sections from the water section is less than 1%. Conclusion: Accurate alignment of PET and CT images is critical to ensure proper calculation and application of CT-based attenuation correction. This study presents a simple and quick method to evaluate the two with a single acquisition. As the phantom also includes spheres of increasing diameter, this could serve as a straightforward means to annually evaluate the status of a modern PET/CT system.

  15. Motion correction in simultaneous PET/MR brain imaging using sparsely sampled MR navigators

    DEFF Research Database (Denmark)

    Keller, Sune H; Hansen, Casper; Hansen, Christian

    2015-01-01

    BACKGROUND: We present a study performing motion correction (MC) of PET using MR navigators sampled between other protocolled MR sequences during simultaneous PET/MR brain scanning with the purpose of evaluating its clinical feasibility and the potential improvement of image quality. FINDINGS......: Twenty-nine human subjects had a 30-min [(11)C]-PiB PET scan with simultaneous MR including 3D navigators sampled at six time points, which were used to correct the PET image for rigid head motion. Five subjects with motion greater than 4 mm were reconstructed into six frames (one for each navigator...

  16. Association of ACE, FABP2 and GST genes polymorphism with essential hypertension risk among a North Indian population.

    Science.gov (United States)

    Abbas, Shania; Raza, Syed Tasleem; Chandra, Anu; Rizvi, Saliha; Ahmed, Faisal; Eba, Ale; Mahdi, Farzana

    2015-01-01

    Hypertension has a multi-factorial background based on genetic and environmental interactive factors. ACE, FABP2 and GST genes have been suggested to be involved in the development of hypertension. However, the results have been inconsistent. The present study was carried out to investigate the association of ACE (rs4646994), FABP2 (rs1799883) and GST (GSTM1 null or positive genotype and GSTT1 null or positive genotype) genes polymorphism with essential HTN cases and controls. This study includes 138 essential hypertension (HTN) patients and 116 age-, sex- and ethnicity-matched control subjects. GST (GSTM1 null or positive genotype and GSTT1 null or positive genotype) genes polymorphisms were evaluated by multiplex PCR, ACE (rs4646994) gene polymorphisms by PCR and FABP2 (rs1799883) gene polymorphisms by PCR-RFLP method. Significant differences were obtained in the frequencies of ACE DD, II genotype (p = 0.006, 0.003), GSTT1 null, GSTM1 positive genotype (p = 0.048, 0.010) and FABP2 Ala54/Ala54 genotype (p = 0.049) between essential HTN cases and controls. It is concluded that ACE (rs 4646994), FABP2 (rs1799883) and GST (GSTM1 null or positive genotype and GSTT1 null or positive genotype) genes polymorphism are associated with HTN. Further investigation with a larger sample size may be required to validate this study.

  17. Assessment of endothelial function and myocardial flow reserve using {sup 15}O-water PET without attenuation correction

    Energy Technology Data Exchange (ETDEWEB)

    Tuffier, Stephane; Joubert, Michael; Bailliez, Alban [EA 4650, Normandie Universite, Caen (France); Legallois, Damien [EA 4650, Normandie Universite, Caen (France); Caen University Hospital, Department of Cardiology, Caen (France); Belin, Annette [Caen University Hospital, Department of Cardiac Surgery, Caen (France); Redonnet, Michel [Rouen University Hospital, Department of Cardiac Surgery, Rouen (France); Agostini, Denis [EA 4650, Normandie Universite, Caen (France); Caen University Hospital, Department of Nuclear Medicine, Caen (France); Manrique, Alain [EA 4650, Normandie Universite, Caen (France); Caen University Hospital, Department of Nuclear Medicine, Caen (France); Cyceron PET Centre, Caen (France)

    2016-02-15

    Myocardial blood flow (MBF) measurement using positron emission tomography (PET) from the washout rate of {sup 15}O-water is theoretically independent of tissue attenuation. The aim of this study was to evaluate the impact of not using attenuation correction in the assessment of coronary endothelial function and myocardial flow reserve (MFR) using {sup 15}O-water PET. We retrospectively processed 70 consecutive {sup 15}O-water PET examinations obtained at rest and during cold pressor testing (CPT) in patients with dilated cardiomyopathy (n = 58), or at rest and during adenosine infusion in heart transplant recipients (n = 12). Data were reconstructed with attenuation correction (AC) and without attenuation correction (NAC) using filtered backprojection, and MBF was quantified using a single compartmental model. The agreement between AC and NAC data was assessed using Lin's concordance correlation coefficient followed by Bland-Altman plot analysis. Regarding endothelial function, NAC PET showed poor reproducibility and poor agreement with AC PET data. Conversely, NAC PET demonstrated high reproducibility and a strong agreement with AC PET for the assessment of MFR. Non-attenuation-corrected {sup 15}O-water PET provided an accurate measurement of MFR compared to attenuation-corrected PET. However, non-attenuation-corrected PET data were less effective for the assessment of endothelial function using CPT in this population. (orig.)

  18. Telomere length is associated with ACE I/D polymorphism in hypertensive patients with left ventricular hypertrophy

    DEFF Research Database (Denmark)

    Fyhrquist, Frej; Eriksson, Anders; Saijonmaa, Outi

    2013-01-01

    INTRODUCTION: Short telomeres are often associated with cardiovascular risk factors and age-related diseases, while the angiotensin converting enzyme (ACE) gene insertion/deletion polymorphism (DD, ID, II) has shown such associations less consistently. We hypothesized that telomere length...... and association of telomere length with cardiovascular risk is affected by ACE (I/D) genotype. METHODS: We measured leucocyte telomere length (LTL) by Southern blot and analysed ACE I/D genotypes in 1249 subjects with hypertension and left ventricular hypertrophy (LVH). We examined interactions of ACE I...

  19. A influência do genótipo da ECA sobre a aptidão cardiovascular de jovens do sexo masculino moderadamente ativos The influence of ACE genotype on cardiovascular fitness of moderately active young men

    Directory of Open Access Journals (Sweden)

    Jeeser Alves Almeida

    2012-04-01

    Full Text Available FUNDAMENTO: O gene da enzima conversora de angiotensina (gene ECA tem sido amplamente estudado em relação a fenótipos de aptidão cardiorrespiratória, contudo a associação do genótipo da ECA com corridas de meia-distância tem sido pouco investigada. OBJETIVO: O presente estudo investigou a possível influência da enzima conversora de angiotensina (ECA (I/D sobre a aptidão cardiovascular e o desempenho em corridas de meia-distância por parte de brasileiros jovens do sexo masculino. A validade da previsão de VO2max em relação ao genótipo da ECA também foi analisada. MÉTODOS: Um grupo homogêneo de homens jovens moderadamente ativos foi avaliado em um teste de corrida (V1600 m; m.min-1 e em um teste adicional em esteira ergométrica para a determinação de VO2max. Posteriormente, o [(0,177*V1600m + 8.101] VO2max real e previsto foi comparado com os genótipos da ECA. RESULTADOS: O VO2max e V1600m registrados para os genótipos DD, ID e II foram 45,6 (1,8; 51,9 (0,8 e 54,4 (1,0 mL.kg-1.min-1 e 211,2 (8,3; 249,1 (4,3 e 258,6 (5,4 m.min-1, respectivamente e foram significativamente mais baixos para os genótipos DD (p BACKGROUND: The angiotensin I-converting enzyme gene (ACE gene has been broadly studied as for cardiorespiratory fitness phenotypes, but the association of the ACE genotype to middle-distance running has been poorly investigated. OBJECTIVE: This study investigated the possible influence of Angiotensin-Converting Enzyme (ACE genotype (I/D on cardiovascular fitness and middle-distance running performance of Brazilian young males. The validity of VO2max to predict the ACE genotype was also analyzed. METHODS: A homogeneous group of moderately active young males were evaluated in a 1,600 m running track test (V1600m; m.min-1 and in an incremental treadmill test for VO2max determination. Subsequently, the actual and the predicted [(0.177*V1600m + 8.101] VO2max were compared to ACE genotypes. RESULTS: The VO2max and V1600m

  20. Direct Parametric Reconstruction With Joint Motion Estimation/Correction for Dynamic Brain PET Data.

    Science.gov (United States)

    Jiao, Jieqing; Bousse, Alexandre; Thielemans, Kris; Burgos, Ninon; Weston, Philip S J; Schott, Jonathan M; Atkinson, David; Arridge, Simon R; Hutton, Brian F; Markiewicz, Pawel; Ourselin, Sebastien

    2017-01-01

    Direct reconstruction of parametric images from raw photon counts has been shown to improve the quantitative analysis of dynamic positron emission tomography (PET) data. However it suffers from subject motion which is inevitable during the typical acquisition time of 1-2 hours. In this work we propose a framework to jointly estimate subject head motion and reconstruct the motion-corrected parametric images directly from raw PET data, so that the effects of distorted tissue-to-voxel mapping due to subject motion can be reduced in reconstructing the parametric images with motion-compensated attenuation correction and spatially aligned temporal PET data. The proposed approach is formulated within the maximum likelihood framework, and efficient solutions are derived for estimating subject motion and kinetic parameters from raw PET photon count data. Results from evaluations on simulated [ 11 C]raclopride data using the Zubal brain phantom and real clinical [ 18 F]florbetapir data of a patient with Alzheimer's disease show that the proposed joint direct parametric reconstruction motion correction approach can improve the accuracy of quantifying dynamic PET data with large subject motion.

  1. Evaluation of scatter limitation correction: a new method of correcting photopenic artifacts caused by patient motion during whole-body PET/CT imaging.

    Science.gov (United States)

    Miwa, Kenta; Umeda, Takuro; Murata, Taisuke; Wagatsuma, Kei; Miyaji, Noriaki; Terauchi, Takashi; Koizumi, Mitsuru; Sasaki, Masayuki

    2016-02-01

    Overcorrection of scatter caused by patient motion during whole-body PET/computed tomography (CT) imaging can induce the appearance of photopenic artifacts in the PET images. The present study aimed to quantify the accuracy of scatter limitation correction (SLC) for eliminating photopenic artifacts. This study analyzed photopenic artifacts in (18)F-fluorodeoxyglucose ((18)F-FDG) PET/CT images acquired from 12 patients and from a National Electrical Manufacturers Association phantom with two peripheral plastic bottles that simulated the human body and arms, respectively. The phantom comprised a sphere (diameter, 10 or 37 mm) containing fluorine-18 solutions with target-to-background ratios of 2, 4, and 8. The plastic bottles were moved 10 cm posteriorly between CT and PET acquisitions. All PET data were reconstructed using model-based scatter correction (SC), no scatter correction (NSC), and SLC, and the presence or absence of artifacts on the PET images was visually evaluated. The SC and SLC images were also semiquantitatively evaluated using standardized uptake values (SUVs). Photopenic artifacts were not recognizable in any NSC and SLC image from all 12 patients in the clinical study. The SUVmax of mismatched SLC PET/CT images were almost equal to those of matched SC and SLC PET/CT images. Applying NSC and SLC substantially eliminated the photopenic artifacts on SC PET images in the phantom study. SLC improved the activity concentration of the sphere for all target-to-background ratios. The highest %errors of the 10 and 37-mm spheres were 93.3 and 58.3%, respectively, for mismatched SC, and 73.2 and 22.0%, respectively, for mismatched SLC. Photopenic artifacts caused by SC error induced by CT and PET image misalignment were corrected using SLC, indicating that this method is useful and practical for clinical qualitative and quantitative PET/CT assessment.

  2. Concurrent Respiratory Motion Correction of Abdominal PET and DCE-MRI using a Compressed Sensing Approach.

    Science.gov (United States)

    Fuin, Niccolo; Catalano, Onofrio Antonio; Scipioni, Michele; Canjels, Lisanne P W; Izquierdo, David; Pedemonte, Stefano; Catana, Ciprian

    2018-01-25

    Purpose: We present an approach for concurrent reconstruction of respiratory motion compensated abdominal DCE-MRI and PET data in an integrated PET/MR scanner. The MR and PET reconstructions share the same motion vector fields (MVFs) derived from radial MR data; the approach is robust to changes in respiratory pattern and do not increase the total acquisition time. Methods: PET and DCE-MRI data of 12 oncological patients were simultaneously acquired for 6 minutes on an integrated PET/MR system after administration of 18 F-FDG and gadoterate meglumine. Golden-angle radial MR data were continuously acquired simultaneously with PET data and sorted into multiple motion phases based on a respiratory signal derived directly from the radial MR data. The resulting multidimensional dataset was reconstructed using a compressed sensing approach that exploits sparsity among respiratory phases. MVFs obtained using the full 6-minute (MC_6-min) and only the last 1 minute (MC_1-min) of data were incorporated into the PET reconstruction to obtain motion-corrected PET images and in an MR iterative reconstruction algorithm to produce a series of motion-corrected DCE-MRI images (moco_GRASP). The motion-correction methods (MC_6-min and MC_1-min) were evaluated by qualitative analysis of the MR images and quantitative analysis of maximum and mean standardized uptake values (SUV max , SUVmean), contrast, signal-to-noise ratio (SNR) and lesion volume in the PET images. Results: Motion corrected MC_6-min PET images demonstrated 30%, 23%, 34% and 18% increases in average SUV max , SUVmean, contrast and SNR, and an average 40% reduction in lesion volume with respect to the non-motion-corrected PET images. The changes in these figures of merit were smaller but still substantial for the MC_1-min protocol: 19%, 10%, 15% and 9% increases in average SUV max , SUVmean, contrast and SNR; and a 28% reduction in lesion volume. Moco_GRASP images were deemed of acceptable or better diagnostic image

  3. Keeping pace with ACE: are ACE inhibitors and angiotensin II type 1 receptor antagonists potential doping agents?

    Science.gov (United States)

    Wang, Pei; Fedoruk, Matthew N; Rupert, Jim L

    2008-01-01

    In the decade since the angiotensin-converting enzyme (ACE) gene was first proposed to be a 'human gene for physical performance', there have been numerous studies examining the effects of ACE genotype on physical performance phenotypes such as aerobic capacity, muscle function, trainability, and athletic status. While the results are variable and sometimes inconsistent, and corroborating phenotypic data limited, carriers of the ACE 'insertion' allele (the presence of an alu repeat element in intron 16 of the gene) have been reported to have higher maximum oxygen uptake (VO2max), greater response to training, and increased muscle efficiency when compared with individuals carrying the 'deletion' allele (absence of the alu repeat). Furthermore, the insertion allele has been reported to be over-represented in elite athletes from a variety of populations representing a number of endurance sports. The mechanism by which the ACE insertion genotype could potentiate physical performance is unknown. The presence of the ACE insertion allele has been associated with lower ACE activity (ACEplasma) in number of studies, suggesting that individuals with an innate tendency to have lower ACE levels respond better to training and are at an advantage in endurance sporting events. This could be due to lower levels of angiotensin II (the vasoconstrictor converted to active form by ACE), higher levels of bradykinin (a vasodilator degraded by ACE) or some combination of the two phenotypes. Observations that individuals carrying the ACE insertion allele (and presumably lower ACEplasma) have an enhanced response to training or are over-represented amongst elite athletes raises the intriguing question: would individuals with artificially lowered ACEplasma have similar training or performance potential? As there are a number of drugs (i.e. ACE inhibitors and angiotensin II type 1 receptor antagonists [angiotensin receptor blockers--ARBs]) that have the ability to either reduce ACEplasma

  4. PET attenuation correction for rigid MR Tx/Rx coils from 176Lu background activity

    Science.gov (United States)

    Lerche, Christoph W.; Kaltsas, Theodoris; Caldeira, Liliana; Scheins, Jürgen; Rota Kops, Elena; Tellmann, Lutz; Pietrzyk, Uwe; Herzog, Hans; Shah, N. Jon

    2018-02-01

    One challenge for PET-MR hybrid imaging is the correction for attenuation of the 511 keV annihilation radiation by the required RF transmit and/or RF receive coils. Although there are strategies for building PET transparent Tx/Rx coils, such optimised coils still cause significant attenuation of the annihilation radiation leading to artefacts and biases in the reconstructed activity concentrations. We present a straightforward method to measure the attenuation of Tx/Rx coils in simultaneous MR-PET imaging based on the natural 176Lu background contained in the scintillator of the PET detector without the requirement of an external CT scanner or PET scanner with transmission source. The method was evaluated on a prototype 3T MR-BrainPET produced by Siemens Healthcare GmbH, both with phantom studies and with true emission images from patient/volunteer examinations. Furthermore, the count rate stability of the PET scanner and the x-ray properties of the Tx/Rx head coil were investigated. Even without energy extrapolation from the two dominant γ energies of 176Lu to 511 keV, the presented method for attenuation correction, based on the measurement of 176Lu background attenuation, shows slightly better performance than the coil attenuation correction currently used. The coil attenuation correction currently used is based on an external transmission scan with rotating 68Ge sources acquired on a Siemens ECAT HR  +  PET scanner. However, the main advantage of the presented approach is its straightforwardness and ready availability without the need for additional accessories.

  5. Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET-MR: Phantom and patient studies

    International Nuclear Information System (INIS)

    Huang, Chuan; Petibon, Yoann; Ouyang, Jinsong; El Fakhri, Georges; Reese, Timothy G.; Ahlman, Mark A.; Bluemke, David A.

    2015-01-01

    Purpose: Degradation of image quality caused by cardiac and respiratory motions hampers the diagnostic quality of cardiac PET. It has been shown that improved diagnostic accuracy of myocardial defect can be achieved by tagged MR (tMR) based PET motion correction using simultaneous PET-MR. However, one major hurdle for the adoption of tMR-based PET motion correction in the PET-MR routine is the long acquisition time needed for the collection of fully sampled tMR data. In this work, the authors propose an accelerated tMR acquisition strategy using parallel imaging and/or compressed sensing and assess the impact on the tMR-based motion corrected PET using phantom and patient data. Methods: Fully sampled tMR data were acquired simultaneously with PET list-mode data on two simultaneous PET-MR scanners for a cardiac phantom and a patient. Parallel imaging and compressed sensing were retrospectively performed by GRAPPA and kt-FOCUSS algorithms with various acceleration factors. Motion fields were estimated using nonrigid B-spline image registration from both the accelerated and fully sampled tMR images. The motion fields were incorporated into a motion corrected ordered subset expectation maximization reconstruction algorithm with motion-dependent attenuation correction. Results: Although tMR acceleration introduced image artifacts into the tMR images for both phantom and patient data, motion corrected PET images yielded similar image quality as those obtained using the fully sampled tMR images for low to moderate acceleration factors (<4). Quantitative analysis of myocardial defect contrast over ten independent noise realizations showed similar results. It was further observed that although the image quality of the motion corrected PET images deteriorates for high acceleration factors, the images were still superior to the images reconstructed without motion correction. Conclusions: Accelerated tMR images obtained with more than 4 times acceleration can still provide

  6. Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET-MR: Phantom and patient studies

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Chuan, E-mail: chuan.huang@stonybrookmedicine.edu [Center for Advanced Medical Imaging Sciences, Division of Nuclear Medicine and Molecular Imaging, Department of Imaging, Massachusetts General Hospital, Boston, Massachusetts 02114 (United States); Department of Radiology, Harvard Medical School, Boston, Massachusetts 02115 (United States); Departments of Radiology, Psychiatry, Stony Brook Medicine, Stony Brook, New York 11794 (United States); Petibon, Yoann [Center for Advanced Medical Imaging Sciences, Division of Nuclear Medicine and Molecular Imaging, Department of Imaging, Massachusetts General Hospital, Boston, Massachusetts 02114 (United States); Ouyang, Jinsong; El Fakhri, Georges [Center for Advanced Medical Imaging Sciences, Division of Nuclear Medicine and Molecular Imaging, Department of Imaging, Massachusetts General Hospital, Boston, Massachusetts 02114 and Department of Radiology, Harvard Medical School, Boston, Massachusetts 02115 (United States); Reese, Timothy G. [Department of Radiology, Harvard Medical School, Boston, Massachusetts 02115 and Martinos Center for Biomedical Imaging, Charlestown, Massachusetts 02129 (United States); Ahlman, Mark A.; Bluemke, David A. [Radiology and Imaging Sciences, National Institutes of Health Clinical Center, Bethesda, Maryland 20892 (United States)

    2015-02-15

    Purpose: Degradation of image quality caused by cardiac and respiratory motions hampers the diagnostic quality of cardiac PET. It has been shown that improved diagnostic accuracy of myocardial defect can be achieved by tagged MR (tMR) based PET motion correction using simultaneous PET-MR. However, one major hurdle for the adoption of tMR-based PET motion correction in the PET-MR routine is the long acquisition time needed for the collection of fully sampled tMR data. In this work, the authors propose an accelerated tMR acquisition strategy using parallel imaging and/or compressed sensing and assess the impact on the tMR-based motion corrected PET using phantom and patient data. Methods: Fully sampled tMR data were acquired simultaneously with PET list-mode data on two simultaneous PET-MR scanners for a cardiac phantom and a patient. Parallel imaging and compressed sensing were retrospectively performed by GRAPPA and kt-FOCUSS algorithms with various acceleration factors. Motion fields were estimated using nonrigid B-spline image registration from both the accelerated and fully sampled tMR images. The motion fields were incorporated into a motion corrected ordered subset expectation maximization reconstruction algorithm with motion-dependent attenuation correction. Results: Although tMR acceleration introduced image artifacts into the tMR images for both phantom and patient data, motion corrected PET images yielded similar image quality as those obtained using the fully sampled tMR images for low to moderate acceleration factors (<4). Quantitative analysis of myocardial defect contrast over ten independent noise realizations showed similar results. It was further observed that although the image quality of the motion corrected PET images deteriorates for high acceleration factors, the images were still superior to the images reconstructed without motion correction. Conclusions: Accelerated tMR images obtained with more than 4 times acceleration can still provide

  7. Quantitative Evaluation of Atlas-based Attenuation Correction for Brain PET in an Integrated Time-of-Flight PET/MR Imaging System.

    Science.gov (United States)

    Yang, Jaewon; Jian, Yiqiang; Jenkins, Nathaniel; Behr, Spencer C; Hope, Thomas A; Larson, Peder E Z; Vigneron, Daniel; Seo, Youngho

    2017-07-01

    Purpose To assess the patient-dependent accuracy of atlas-based attenuation correction (ATAC) for brain positron emission tomography (PET) in an integrated time-of-flight (TOF) PET/magnetic resonance (MR) imaging system. Materials and Methods Thirty recruited patients provided informed consent in this institutional review board-approved study. All patients underwent whole-body fluorodeoxyglucose PET/computed tomography (CT) followed by TOF PET/MR imaging. With use of TOF PET data, PET images were reconstructed with four different attenuation correction (AC) methods: PET with patient CT-based AC (CTAC), PET with ATAC (air and bone from an atlas), PET with ATAC patientBone (air and tissue from the atlas with patient bone), and PET with ATAC boneless (air and tissue from the atlas without bone). For quantitative evaluation, PET mean activity concentration values were measured in 14 1-mL volumes of interest (VOIs) distributed throughout the brain and statistical significance was tested with a paired t test. Results The mean overall difference (±standard deviation) of PET with ATAC compared with PET with CTAC was -0.69 kBq/mL ± 0.60 (-4.0% ± 3.2) (P PET with ATAC boneless (-9.4% ± 3.7) was significantly worse than that of PET with ATAC (-4.0% ± 3.2) (P PET with ATAC patientBone (-1.5% ± 1.5) improved over that of PET with ATAC (-4.0% ± 3.2) (P PET/MR imaging achieves similar quantification accuracy to that from CTAC by means of atlas-based bone compensation. However, patient-specific anatomic differences from the atlas causes bone attenuation differences and misclassified sinuses, which result in patient-dependent performance variation of ATAC. © RSNA, 2017 Online supplemental material is available for this article.

  8. Automated movement correction for dynamic PET/CT images: evaluation with phantom and patient data.

    Science.gov (United States)

    Ye, Hu; Wong, Koon-Pong; Wardak, Mirwais; Dahlbom, Magnus; Kepe, Vladimir; Barrio, Jorge R; Nelson, Linda D; Small, Gary W; Huang, Sung-Cheng

    2014-01-01

    Head movement during a dynamic brain PET/CT imaging results in mismatch between CT and dynamic PET images. It can cause artifacts in CT-based attenuation corrected PET images, thus affecting both the qualitative and quantitative aspects of the dynamic PET images and the derived parametric images. In this study, we developed an automated retrospective image-based movement correction (MC) procedure. The MC method first registered the CT image to each dynamic PET frames, then re-reconstructed the PET frames with CT-based attenuation correction, and finally re-aligned all the PET frames to the same position. We evaluated the MC method's performance on the Hoffman phantom and dynamic FDDNP and FDG PET/CT images of patients with neurodegenerative disease or with poor compliance. Dynamic FDDNP PET/CT images (65 min) were obtained from 12 patients and dynamic FDG PET/CT images (60 min) were obtained from 6 patients. Logan analysis with cerebellum as the reference region was used to generate regional distribution volume ratio (DVR) for FDDNP scan before and after MC. For FDG studies, the image derived input function was used to generate parametric image of FDG uptake constant (Ki) before and after MC. Phantom study showed high accuracy of registration between PET and CT and improved PET images after MC. In patient study, head movement was observed in all subjects, especially in late PET frames with an average displacement of 6.92 mm. The z-direction translation (average maximum = 5.32 mm) and x-axis rotation (average maximum = 5.19 degrees) occurred most frequently. Image artifacts were significantly diminished after MC. There were significant differences (Pdynamic brain FDDNP and FDG PET/CT scans could improve the qualitative and quantitative aspects of images of both tracers.

  9. The role of IL-4 gene 70 bp VNTR and ACE gene I/D variants in Familial Mediterranean fever.

    Science.gov (United States)

    Yigit, Serbülent; Tural, Sengul; Tekcan, Akın; Tasliyurt, Turker; Inanir, Ahmet; Uzunkaya, Süheyla; Kismali, Gorkem

    2014-05-01

    Familial Mediterranean fever (FMF) is characterized by recurrent attacks of fever and inflammation in the peritoneum, synovium, or pleura, accompanied by pain. It is an autosomal recessive disease caused by mutations in the MEFV (MEditerranean FeVer) gene. Patients with similar genotypes exhibit phenotypic diversity. As a result, the variations in different genes could be responsible for the clinical findings of this disease. In previous studies genes encoding Angiotensin-Converting Enzyme (ACE) and IL-4 (Interleukin-4) were found to be associated with rheumatologic and autoimmune diseases. In the present study we hypothesized whether ACE I/D or IL-4 70 bp variable tandem repeats (VNTR) genes are associated with FMF and its clinical findings in Turkish patients. Genomic DNA obtained from 670 persons (339 patients with FMF and 331 healthy controls) was used in the study. Genotypes for an ACE gene I/D polymorphism and IL-4 gene 70 bp VNTR were determined by polymerase chain reaction with specific primers. To our knowledge, this is the first study examining ACE gene I/D polymorphism and IL-4 gene 70 bp VNTR polymorphism in FMF patients. As a result, there was a statistically significant difference between the groups with respect to genotype distribution (pACE gene DD genotype was associated with an increased risk in FMF [pACE genotype frequencies according to the clinical characteristics, we found a statistically significant association between DD+ID genotype and fever (p=0.04). In addition IL-4 gene P1P1 genotype was associated with FMF (pACE gene and P1 allele or P1P1 genotype of IL-4 gene may be important molecular markers for susceptibility of FMF. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Experimental validation of gallium production and isotope-dependent positron range correction in PET

    Energy Technology Data Exchange (ETDEWEB)

    Fraile, L.M., E-mail: lmfraile@ucm.es [Grupo de Física Nuclear, Dpto. Física Atómica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Herraiz, J.L.; Udías, J.M.; Cal-González, J.; Corzo, P.M.G.; España, S.; Herranz, E.; Pérez-Liva, M.; Picado, E.; Vicente, E. [Grupo de Física Nuclear, Dpto. Física Atómica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Muñoz-Martín, A. [Centro de Microanálisis de Materiales, Universidad Autónoma de Madrid, E-28049 Madrid (Spain); Vaquero, J.J. [Departamento de Bioingeniería e Ingeniería Aeroespacial, Universidad Carlos III de Madrid (Spain)

    2016-04-01

    Positron range (PR) is one of the important factors that limit the spatial resolution of positron emission tomography (PET) preclinical images. Its blurring effect can be corrected to a large extent if the appropriate method is used during the image reconstruction. Nevertheless, this correction requires an accurate modelling of the PR for the particular radionuclide and materials in the sample under study. In this work we investigate PET imaging with {sup 68}Ga and {sup 66}Ga radioisotopes, which have a large PR and are being used in many preclinical and clinical PET studies. We produced a {sup 68}Ga and {sup 66}Ga phantom on a natural zinc target through (p,n) reactions using the 9-MeV proton beam delivered by the 5-MV CMAM tandetron accelerator. The phantom was imaged in an ARGUS small animal PET/CT scanner and reconstructed with a fully 3D iterative algorithm, with and without PR corrections. The reconstructed images at different time frames show significant improvement in spatial resolution when the appropriate PR is applied for each frame, by taking into account the relative amount of each isotope in the sample. With these results we validate our previously proposed PR correction method for isotopes with large PR. Additionally, we explore the feasibility of PET imaging with {sup 68}Ga and {sup 66}Ga radioisotopes in proton therapy.

  11. Correction of oral contrast artifacts in CT-based attenuation correction of PET images using an automated segmentation algorithm

    International Nuclear Information System (INIS)

    Ahmadian, Alireza; Ay, Mohammad R.; Sarkar, Saeed; Bidgoli, Javad H.; Zaidi, Habib

    2008-01-01

    Oral contrast is usually administered in most X-ray computed tomography (CT) examinations of the abdomen and the pelvis as it allows more accurate identification of the bowel and facilitates the interpretation of abdominal and pelvic CT studies. However, the misclassification of contrast medium with high-density bone in CT-based attenuation correction (CTAC) is known to generate artifacts in the attenuation map (μmap), thus resulting in overcorrection for attenuation of positron emission tomography (PET) images. In this study, we developed an automated algorithm for segmentation and classification of regions containing oral contrast medium to correct for artifacts in CT-attenuation-corrected PET images using the segmented contrast correction (SCC) algorithm. The proposed algorithm consists of two steps: first, high CT number object segmentation using combined region- and boundary-based segmentation and second, object classification to bone and contrast agent using a knowledge-based nonlinear fuzzy classifier. Thereafter, the CT numbers of pixels belonging to the region classified as contrast medium are substituted with their equivalent effective bone CT numbers using the SCC algorithm. The generated CT images are then down-sampled followed by Gaussian smoothing to match the resolution of PET images. A piecewise calibration curve was then used to convert CT pixel values to linear attenuation coefficients at 511 keV. The visual assessment of segmented regions performed by an experienced radiologist confirmed the accuracy of the segmentation and classification algorithms for delineation of contrast-enhanced regions in clinical CT images. The quantitative analysis of generated μmaps of 21 clinical CT colonoscopy datasets showed an overestimation ranging between 24.4% and 37.3% in the 3D-classified regions depending on their volume and the concentration of contrast medium. Two PET/CT studies known to be problematic demonstrated the applicability of the technique in

  12. PET measurements of cerebral metabolism corrected for CSF contributions

    International Nuclear Information System (INIS)

    Chawluk, J.; Alavi, A.; Dann, R.; Kushner, M.J.; Hurtig, H.; Zimmerman, R.A.; Reivich, M.

    1984-01-01

    Thirty-three subjects have been studied with PET and anatomic imaging (proton-NMR and/or CT) in order to determine the effect of cerebral atrophy on calculations of metabolic rates. Subgroups of neurologic disease investigated include stroke, brain tumor, epilepsy, psychosis, and dementia. Anatomic images were digitized through a Vidicon camera and analyzed volumetrically. Relative areas for ventricles, sulci, and brain tissue were calculated. Preliminary analysis suggests that ventricular volumes as determined by NMR and CT are similar, while sulcal volumes are larger on NMR scans. Metabolic rates (18F-FDG) were calculated before and after correction for CSF spaces, with initial focus upon dementia and normal aging. Correction for atrophy led to a greater increase (%) in global metabolic rates in demented individuals (18.2 +- 5.3) compared to elderly controls (8.3 +- 3.0,p < .05). A trend towards significantly lower glucose metabolism in demented subjects before CSF correction was not seen following correction for atrophy. These data suggest that volumetric analysis of NMR images may more accurately reflect the degree of cerebral atrophy, since NMR does not suffer from beam hardening artifact due to bone-parenchyma juxtapositions. Furthermore, appropriate correction for CSF spaces should be employed if current resolution PET scanners are to accurately measure residual brain tissue metabolism in various pathological states

  13. Correction of MRI-induced geometric distortions in whole-body small animal PET-MRI

    International Nuclear Information System (INIS)

    Frohwein, Lynn J.; Schäfers, Klaus P.; Hoerr, Verena; Faber, Cornelius

    2015-01-01

    Purpose: The fusion of positron emission tomography (PET) and magnetic resonance imaging (MRI) data can be a challenging task in whole-body PET-MRI. The quality of the registration between these two modalities in large field-of-views (FOV) is often degraded by geometric distortions of the MRI data. The distortions at the edges of large FOVs mainly originate from MRI gradient nonlinearities. This work describes a method to measure and correct for these kind of geometric distortions in small animal MRI scanners to improve the registration accuracy of PET and MRI data. Methods: The authors have developed a geometric phantom which allows the measurement of geometric distortions in all spatial axes via control points. These control points are detected semiautomatically in both PET and MRI data with a subpixel accuracy. The spatial transformation between PET and MRI data is determined with these control points via 3D thin-plate splines (3D TPS). The transformation derived from the 3D TPS is finally applied to real MRI mouse data, which were acquired with the same scan parameters used in the phantom data acquisitions. Additionally, the influence of the phantom material on the homogeneity of the magnetic field is determined via field mapping. Results: The spatial shift according to the magnetic field homogeneity caused by the phantom material was determined to a mean of 0.1 mm. The results of the correction show that distortion with a maximum error of 4 mm could be reduced to less than 1 mm with the proposed correction method. Furthermore, the control point-based registration of PET and MRI data showed improved congruence after correction. Conclusions: The developed phantom has been shown to have no considerable negative effect on the homogeneity of the magnetic field. The proposed method yields an appropriate correction of the measured MRI distortion and is able to improve the PET and MRI registration. Furthermore, the method is applicable to whole-body small animal

  14. Correction of MRI-induced geometric distortions in whole-body small animal PET-MRI

    Energy Technology Data Exchange (ETDEWEB)

    Frohwein, Lynn J., E-mail: frohwein@uni-muenster.de; Schäfers, Klaus P. [European Institute for Molecular Imaging, University of Münster, Münster 48149 (Germany); Hoerr, Verena; Faber, Cornelius [Department of Clinical Radiology, University Hospital of Münster, Münster 48149 (Germany)

    2015-07-15

    Purpose: The fusion of positron emission tomography (PET) and magnetic resonance imaging (MRI) data can be a challenging task in whole-body PET-MRI. The quality of the registration between these two modalities in large field-of-views (FOV) is often degraded by geometric distortions of the MRI data. The distortions at the edges of large FOVs mainly originate from MRI gradient nonlinearities. This work describes a method to measure and correct for these kind of geometric distortions in small animal MRI scanners to improve the registration accuracy of PET and MRI data. Methods: The authors have developed a geometric phantom which allows the measurement of geometric distortions in all spatial axes via control points. These control points are detected semiautomatically in both PET and MRI data with a subpixel accuracy. The spatial transformation between PET and MRI data is determined with these control points via 3D thin-plate splines (3D TPS). The transformation derived from the 3D TPS is finally applied to real MRI mouse data, which were acquired with the same scan parameters used in the phantom data acquisitions. Additionally, the influence of the phantom material on the homogeneity of the magnetic field is determined via field mapping. Results: The spatial shift according to the magnetic field homogeneity caused by the phantom material was determined to a mean of 0.1 mm. The results of the correction show that distortion with a maximum error of 4 mm could be reduced to less than 1 mm with the proposed correction method. Furthermore, the control point-based registration of PET and MRI data showed improved congruence after correction. Conclusions: The developed phantom has been shown to have no considerable negative effect on the homogeneity of the magnetic field. The proposed method yields an appropriate correction of the measured MRI distortion and is able to improve the PET and MRI registration. Furthermore, the method is applicable to whole-body small animal

  15. Automatic correction of dental artifacts in PET/MRI

    DEFF Research Database (Denmark)

    Ladefoged, Claes N.; Andersen, Flemming L.; Keller, Sune

    2015-01-01

    A challenge when using current magnetic resonance (MR)-based attenuation correction in positron emission tomography/MR imaging (PET/MRI) is that the MRIs can have a signal void around the dental fillings that is segmented as artificial air-regions in the attenuation map. For artifacts connected...

  16. The evaluation of the effect of attenuation correction on lesion detectability in whole-body FDG-PET

    International Nuclear Information System (INIS)

    Tomemori, Takashi; Uno, Kimiichi; Oka, Takashi; Suzuki, Takayuki; Tomiyoshi, Katsumi; Jin Wu

    2004-01-01

    The aim of this study was to compare the attenuation corrected and non-corrected FDG-PET images in patients with malignant lesions and to evaluate the effect of attenuation correction on lesion detectability. A total of 71 persons with 112 malignant lesions was examined. All subjects fasted for at least 4 hours before PET study and whole-body PET imaging was performed 45 min after the intravenous administration of FDG (mean dose: 273.8 MBq). Emission scans of 6 min and post-injection transmission scans of 6 min per bed position were used. The intensity of lesion uptake in FDG-PET image was visually classified into 3 grades; grade 2=the lesion was clearly identified in the maximum intensity projection (MIP) image of FDG-PET, grade 1=the lesion was not identified in MIP image but it can be identified in coronal image, grade 0=there was no contrast between lesion and background in both MIP and coronal image. Ninety-eight lesions (87.5%) were classified into same grade in both attenuation corrected and non-corrected image, but in 11 lesions (9.8%) attenuation corrected image was better lesion visualization than non-corrected image. All lesions divided between the primary lesions and the metastatic lesions. In 50 primary lesions, 43 lesions were depicted in both attenuation corrected and non-corrected image and other 7 lesions were not in both image. In 62 metastatic lesions, 50 lesions (80.7%) were classified into same grade in both attenuation corrected and non-corrected image, but in 10 lesions (16.1%) attenuation corrected image were better lesion visualization than non-corrected image. In the most cases, the lesions were depicted in both attenuation corrected and non-corrected image. In the primary lesions, the lesion detectability between attenuation corrected and non-corrected image was similar. But in some cases with the metastatic lesions, attenuation corrected image were better lesion visualization than non-corrected image. For asymptomatic patients, non-corrected

  17. Improved correction for the tissue fraction effect in lung PET/CT imaging

    International Nuclear Information System (INIS)

    Holman, Beverley F; Cuplov, Vesna; Millner, Lynn; Hutton, Brian F; Groves, Ashley M; Thielemans, Kris; Maher, Toby M

    2015-01-01

    Recently, there has been an increased interest in imaging different pulmonary disorders using PET techniques. Previous work has shown, for static PET/CT, that air content in the lung influences reconstructed image values and that it is vital to correct for this ‘tissue fraction effect’ (TFE). In this paper, we extend this work to include the blood component and also investigate the TFE in dynamic imaging. CT imaging and PET kinetic modelling are used to determine fractional air and blood voxel volumes in six patients with idiopathic pulmonary fibrosis. These values are used to illustrate best and worst case scenarios when interpreting images without correcting for the TFE. In addition, the fractional volumes were used to determine correction factors for the SUV and the kinetic parameters. These were then applied to the patient images. The kinetic parameters K 1 and K i along with the static parameter SUV were all found to be affected by the TFE with both air and blood providing a significant contribution to the errors. Without corrections, errors range from 34–80% in the best case and 29–96% in the worst case. In the patient data, without correcting for the TFE, regions of high density (fibrosis) appeared to have a higher uptake than lower density (normal appearing tissue), however this was reversed after air and blood correction. The proposed correction methods are vital for quantitative and relative accuracy. Without these corrections, images may be misinterpreted. (paper)

  18. Improved correction for the tissue fraction effect in lung PET/CT imaging

    Science.gov (United States)

    Holman, Beverley F.; Cuplov, Vesna; Millner, Lynn; Hutton, Brian F.; Maher, Toby M.; Groves, Ashley M.; Thielemans, Kris

    2015-09-01

    Recently, there has been an increased interest in imaging different pulmonary disorders using PET techniques. Previous work has shown, for static PET/CT, that air content in the lung influences reconstructed image values and that it is vital to correct for this ‘tissue fraction effect’ (TFE). In this paper, we extend this work to include the blood component and also investigate the TFE in dynamic imaging. CT imaging and PET kinetic modelling are used to determine fractional air and blood voxel volumes in six patients with idiopathic pulmonary fibrosis. These values are used to illustrate best and worst case scenarios when interpreting images without correcting for the TFE. In addition, the fractional volumes were used to determine correction factors for the SUV and the kinetic parameters. These were then applied to the patient images. The kinetic parameters K1 and Ki along with the static parameter SUV were all found to be affected by the TFE with both air and blood providing a significant contribution to the errors. Without corrections, errors range from 34-80% in the best case and 29-96% in the worst case. In the patient data, without correcting for the TFE, regions of high density (fibrosis) appeared to have a higher uptake than lower density (normal appearing tissue), however this was reversed after air and blood correction. The proposed correction methods are vital for quantitative and relative accuracy. Without these corrections, images may be misinterpreted.

  19. Is the association between ACE genes and blood pressure mediated by postnatal growth during the first 3 years?

    Science.gov (United States)

    Min, JungWon; Kim, Young Ju; Lee, Hwayoung; Park, Eun Ae; Cho, Su Jin; Hong, Young Mi; Oh, Se-Young; Ha, Eunhee; Kang, DukHee; Park, Hyesook

    2012-06-01

    Unlike the defined role of angiotensin-converting enzyme (ACE) gene in adult hypertension, ACE gene did not show direct influence on childhood blood pressure (BP), rather, seemed to be related to childhood growth with age-dependent characteristics. Thus, we examined intermediate effects of postnatal growth between the ACE polymorphisms and BP. We analyzed data from 257 children born in 2001-04 at Ewha Womans University Hospital in Seoul, Korea, and followed them up until 3 years of age. Children with excessive adiposity had higher BP, as rapid growers did to no-change and decelerated growers. The ACE II genotype was associated with greater growth acceleration than the DD genotype (II: 46.8% vs. DD: 23.9%), and with a higher BP. The interactions between ACE genotype and adiposity at age 3 were significant on the BP levels. The highest BP increase with the same degree of adiposity was observed in those with the II genotype [β (SE) for BMI: 1.9 (0.9), p=0.04]; particularly, only rapid grown II carriers demonstrated statistical significance on this linear association. These results suggested that ACE polymorphisms and BP association are mediated by postnatal growth. Further studies are required to determine the age-specific ACE genetic effects and its undefined biological mechanism. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. Evaluation of attenuation and scatter correction requirements in small animal PET and SPECT imaging

    Science.gov (United States)

    Konik, Arda Bekir

    Positron emission tomography (PET) and single photon emission tomography (SPECT) are two nuclear emission-imaging modalities that rely on the detection of high-energy photons emitted from radiotracers administered to the subject. The majority of these photons are attenuated (absorbed or scattered) in the body, resulting in count losses or deviations from true detection, which in turn degrades the accuracy of images. In clinical emission tomography, sophisticated correction methods are often required employing additional x-ray CT or radionuclide transmission scans. Having proven their potential in both clinical and research areas, both PET and SPECT are being adapted for small animal imaging. However, despite the growing interest in small animal emission tomography, little scientific information exists about the accuracy of these correction methods on smaller size objects, and what level of correction is required. The purpose of this work is to determine the role of attenuation and scatter corrections as a function of object size through simulations. The simulations were performed using Interactive Data Language (IDL) and a Monte Carlo based package, Geant4 application for emission tomography (GATE). In IDL simulations, PET and SPECT data acquisition were modeled in the presence of attenuation. A mathematical emission and attenuation phantom approximating a thorax slice and slices from real PET/CT data were scaled to 5 different sizes (i.e., human, dog, rabbit, rat and mouse). The simulated emission data collected from these objects were reconstructed. The reconstructed images, with and without attenuation correction, were compared to the ideal (i.e., non-attenuated) reconstruction. Next, using GATE, scatter fraction values (the ratio of the scatter counts to the total counts) of PET and SPECT scanners were measured for various sizes of NEMA (cylindrical phantoms representing small animals and human), MOBY (realistic mouse/rat model) and XCAT (realistic human model

  1. Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Izquierdo-Garcia, David [Mount Sinai School of Medicine, Translational and Molecular Imaging Institute, New York, NY (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, MA (United States); Sawiak, Stephen J. [University of Cambridge, Wolfson Brain Imaging Centre, Cambridge (United Kingdom); Knesaurek, Karin; Machac, Joseph [Mount Sinai School of Medicine, Division of Nuclear Medicine, Department of Radiology, New York, NY (United States); Narula, Jagat [Mount Sinai School of Medicine, Department of Cardiology, Zena and Michael A. Weiner Cardiovascular Institute and Marie-Josee and Henry R. Kravis Cardiovascular Health Center, New York, NY (United States); Fuster, Valentin [Mount Sinai School of Medicine, Department of Cardiology, Zena and Michael A. Weiner Cardiovascular Institute and Marie-Josee and Henry R. Kravis Cardiovascular Health Center, New York, NY (United States); The Centro Nacional de Investigaciones Cardiovasculares (CNIC), Madrid (Spain); Fayad, Zahi A. [Mount Sinai School of Medicine, Translational and Molecular Imaging Institute, New York, NY (United States); Mount Sinai School of Medicine, Department of Cardiology, Zena and Michael A. Weiner Cardiovascular Institute and Marie-Josee and Henry R. Kravis Cardiovascular Health Center, New York, NY (United States); Mount Sinai School of Medicine, Department of Radiology, New York, NY (United States)

    2014-08-15

    The objective of this study was to evaluate the performance of the built-in MR-based attenuation correction (MRAC) included in the combined whole-body Ingenuity TF PET/MR scanner and compare it to the performance of CT-based attenuation correction (CTAC) as the gold standard. Included in the study were 26 patients who underwent clinical whole-body FDG PET/CT imaging and subsequently PET/MR imaging (mean delay 100 min). Patients were separated into two groups: the alpha group (14 patients) without MR coils during PET/MR imaging and the beta group (12 patients) with MR coils present (neurovascular, spine, cardiac and torso coils). All images were coregistered to the same space (PET/MR). The two PET images from PET/MR reconstructed using MRAC and CTAC were compared by voxel-based and region-based methods (with ten regions of interest, ROIs). Lesions were also compared by an experienced clinician. Body mass index and lung density showed significant differences between the alpha and beta groups. Right and left lung densities were also significantly different within each group. The percentage differences in uptake values using MRAC in relation to those using CTAC were greater in the beta group than in the alpha group (alpha group -0.2 ± 33.6 %, R{sup 2} = 0.98, p < 0.001; beta group 10.31 ± 69.86 %, R{sup 2} = 0.97, p < 0.001). In comparison to CTAC, MRAC led to underestimation of the PET values by less than 10 % on average, although some ROIs and lesions did differ by more (including the spine, lung and heart). The beta group (imaged with coils present) showed increased overall PET quantification as well as increased variability compared to the alpha group (imaged without coils). PET data reconstructed with MRAC and CTAC showed some differences, mostly in relation to air pockets, metallic implants and attenuation differences in large bone areas (such as the pelvis and spine) due to the segmentation limitation of the MRAC method. (orig.)

  2. Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging

    International Nuclear Information System (INIS)

    Izquierdo-Garcia, David; Sawiak, Stephen J.; Knesaurek, Karin; Machac, Joseph; Narula, Jagat; Fuster, Valentin; Fayad, Zahi A.

    2014-01-01

    The objective of this study was to evaluate the performance of the built-in MR-based attenuation correction (MRAC) included in the combined whole-body Ingenuity TF PET/MR scanner and compare it to the performance of CT-based attenuation correction (CTAC) as the gold standard. Included in the study were 26 patients who underwent clinical whole-body FDG PET/CT imaging and subsequently PET/MR imaging (mean delay 100 min). Patients were separated into two groups: the alpha group (14 patients) without MR coils during PET/MR imaging and the beta group (12 patients) with MR coils present (neurovascular, spine, cardiac and torso coils). All images were coregistered to the same space (PET/MR). The two PET images from PET/MR reconstructed using MRAC and CTAC were compared by voxel-based and region-based methods (with ten regions of interest, ROIs). Lesions were also compared by an experienced clinician. Body mass index and lung density showed significant differences between the alpha and beta groups. Right and left lung densities were also significantly different within each group. The percentage differences in uptake values using MRAC in relation to those using CTAC were greater in the beta group than in the alpha group (alpha group -0.2 ± 33.6 %, R 2 = 0.98, p 2 = 0.97, p < 0.001). In comparison to CTAC, MRAC led to underestimation of the PET values by less than 10 % on average, although some ROIs and lesions did differ by more (including the spine, lung and heart). The beta group (imaged with coils present) showed increased overall PET quantification as well as increased variability compared to the alpha group (imaged without coils). PET data reconstructed with MRAC and CTAC showed some differences, mostly in relation to air pockets, metallic implants and attenuation differences in large bone areas (such as the pelvis and spine) due to the segmentation limitation of the MRAC method. (orig.)

  3. Vision 20/20: Magnetic resonance imaging-guided attenuation correction in PET/MRI: Challenges, solutions, and opportunities

    Energy Technology Data Exchange (ETDEWEB)

    Mehranian, Abolfazl; Arabi, Hossein [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva CH-1211 (Switzerland); Zaidi, Habib, E-mail: habib.zaidi@hcuge.ch [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva CH-1211 (Switzerland); Geneva Neuroscience Centre, University of Geneva, Geneva CH-1205 (Switzerland); Department of Nuclear Medicine and Molecular Imaging, University of Groningen, Groningen 9700 RB (Netherlands)

    2016-03-15

    Attenuation correction is an essential component of the long chain of data correction techniques required to achieve the full potential of quantitative positron emission tomography (PET) imaging. The development of combined PET/magnetic resonance imaging (MRI) systems mandated the widespread interest in developing novel strategies for deriving accurate attenuation maps with the aim to improve the quantitative accuracy of these emerging hybrid imaging systems. The attenuation map in PET/MRI should ideally be derived from anatomical MR images; however, MRI intensities reflect proton density and relaxation time properties of biological tissues rather than their electron density and photon attenuation properties. Therefore, in contrast to PET/computed tomography, there is a lack of standardized global mapping between the intensities of MRI signal and linear attenuation coefficients at 511 keV. Moreover, in standard MRI sequences, bones and lung tissues do not produce measurable signals owing to their low proton density and short transverse relaxation times. MR images are also inevitably subject to artifacts that degrade their quality, thus compromising their applicability for the task of attenuation correction in PET/MRI. MRI-guided attenuation correction strategies can be classified in three broad categories: (i) segmentation-based approaches, (ii) atlas-registration and machine learning methods, and (iii) emission/transmission-based approaches. This paper summarizes past and current state-of-the-art developments and latest advances in PET/MRI attenuation correction. The advantages and drawbacks of each approach for addressing the challenges of MR-based attenuation correction are comprehensively described. The opportunities brought by both MRI and PET imaging modalities for deriving accurate attenuation maps and improving PET quantification will be elaborated. Future prospects and potential clinical applications of these techniques and their integration in commercial

  4. Evaluation of Association of ADRA2A rs553668 and ACE I/D Gene Polymorphisms with Obesity Traits in the Setapak Population, Malaysia.

    Science.gov (United States)

    Shunmugam, Vicneswari; Say, Yee-How

    2016-02-01

    α-adrenergic receptor 2A (ADRA2A) and angiotensin-converting enzyme (ACE) genes have been variably associated with obesity and its related phenotypes in different populations worldwide. This cross-sectional study aims to investigate the association of adrenergic receptor α2A (ADRA2A) rs553668 and angiotensin-converting enzyme (ACE) I/D single nucleotide polymorphisms (SNPs) with obesity traits (body mass index-BMI; waist-hip ratio-WHR; total body fat percentage - TBF) in a Malaysian population. Demographic and clinical variables were initially collected from 230 subjects via convenience sampling among residents and workers in Setapak, Malaysia, but in the end only 214 multi-ethnic Malaysians (99 males; 45 Malays, 116 ethnic Chinese, and 53 ethnic Indians) were available for statistical analysis. Genotyping was performed by polymerase chain reaction using DNA extracted from mouthwash samples. The overall minor allele frequencies (MAFs) for ADRA2A rs553668 and ACE I/D were 0.55 and 0.56, respectively. Allele distribution of ACE I/D was significantly associated with ethnicity and WHR class. Logistic regression analysis showed that subjects with the ACE II genotype and I allele were, respectively, 2.15 and 1.55 times more likely to be centrally obese, but when adjusted for age and ethnicity, this association was abolished. Covariate analysis controlling for age, gender, and ethnicity also showed similar results, where subjects carrying the II genotype or I allele did not have significantly higher WHR. Combinatory genotype and allele analysis for ADRA2A rs553668 and ACE I/D showed that subjects with both ADRA2A rs553668 GG and ACE I/D II genotypes had significant lowest WHR compared to other genotype combinations. The ACE II genotype might be a protective factor against central adiposity risk among the Malaysian population when in combination with the ADRA2A rs553668 GG genotype.

  5. Attenuation correction for the NIH ATLAS small animal PET scanner

    CERN Document Server

    Yao, Rutao; Liow, JeihSan; Seidel, Jurgen

    2003-01-01

    We evaluated two methods of attenuation correction for the NIH ATLAS small animal PET scanner: 1) a CT-based method that derives 511 keV attenuation coefficients (mu) by extrapolation from spatially registered CT images; and 2) an analytic method based on the body outline of emission images and an empirical mu. A specially fabricated attenuation calibration phantom with cylindrical inserts that mimic different body tissues was used to derive the relationship to convert CT values to (I for PET. The methods were applied to three test data sets: 1) a uniform cylinder phantom, 2) the attenuation calibration phantom, and 3) a mouse injected with left bracket **1**8F right bracket FDG. The CT-based attenuation correction factors were larger in non-uniform regions of the imaging subject, e.g. mouse head, than the analytic method. The two methods had similar correction factors for regions with uniform density and detectable emission source distributions.

  6. ACE variants interact with the RAS pathway to confer risk and protection against type 2 diabetic nephropathy

    DEFF Research Database (Denmark)

    Ahluwalia, Tarun Veer Singh; Ahuja, Monica; Rai, Taranjit Singh

    2009-01-01

    Genetic predisposition has been proposed to be a major determinant in the development of renal complications of diabetes. Among candidate genes examined for susceptibility to diabetic nephropathy, angiotensin-converting enzyme (ACE) gene has been found to be associated with pathogenesis......, in the present study, we evaluated the association of ACE haplotypes and the interactions of ACE, angiotensinogen (AGT), and angiotensin II receptor type I (AGTR1) gene polymorphisms with DNP in Asian Indians. We genotyped seven variants of the RAS pathway genes (ACE, AGT, and AGTR1) in type 2 diabetic cohorts...... and progression of diabetic nephropathy. However, the role of other renin-angiotensin system (RAS) polymorphisms and their possible interactions with different ACE I/D genotypes are less clearly defined. Recent studies also show that ACE haplotypes may be better predictors to disease susceptibility. Thus...

  7. Common Variants of the ACE Gene and Aneurysmal Subarachnoid Hemorrhage in a Danish Population: A Case-control Study

    DEFF Research Database (Denmark)

    Staalsø, Jonatan Myrup; Nielsen, Morten; Edsen, Troels BS

    2011-01-01

    OBJECTIVE: The intron 16 insertion/deletion (I/D) polymorphism in the angiotensin-converting enzyme (ACE) gene has been associated with rupture of intracranial aneurysms, but the effect of haplotypes within ACE has not been studied. This study investigated whether ACE haplotypes including the I...... C/G, rs4305 C/T, rs4311 C/T, rs4331 T/C, rs4343 C/T) in the ACE gene were genotyped along with the I/D polymorphism. Haplotypes were estimated using the PHASE software. RESULTS: Fifty-five haplotypes were identified with 3 of these having a frequency above 5%: ACCCCIT (41.6±0.4%), TGTTTDC (32.......1±0.5%), and ACCTTDC (9.5±0.2%). No significant difference in distribution of alleles, genotypes, haplotypes, or haplotype pairs between the 2 populations was found. Specifically, we could not reproduce previously reported associations between the ACE I genotype and intracranial aneurysms. When subdivided into groups...

  8. Assessment of the breath motion correction on the detectability of lesions in PET oncology

    International Nuclear Information System (INIS)

    Marache-Francisco, S.

    2012-02-01

    Positron emission tomography (PET) is a nuclear medicine imaging technique that produces a three-dimensional image of functional processes in the body. The system detects pairs of gamma rays emitted by a tracer, which is introduced into the body. Three-dimensional images of tracer concentration within the body are then constructed by computer analysis. Respiratory motion in emission tomography leads to image blurring especially in the lower thorax and the upper abdomen, influencing this way the quantitative accuracy of PET measurements as well as leading to a loss of sensitivity in lesion detection. Although PET exams are getting shorter thanks to the improvement of scanner sensitivity, the current 2-3 minutes acquisitions per bed position are not yet compatible with patient breath-holding. Performing accurate respiratory motion correction without impairing the standard clinical protocol, i.e. without increasing the acquisition time, thus remains challenging. Different types of respiratory motion correction approaches have been proposed, mostly based on the use of non-rigid deformation fields either applied to the gated PET images or integrated during an iterative reconstruction algorithm. Evaluation of theses methods has been mainly focusing on the quantification and localization accuracy of small lesions, but their impact on the clinician detection performance during the diagnostic task has not been fully investigated yet. The purpose of this study is to address this question based on a computer assisted detection study. We evaluate the influence of two motion correction methods on the detection of small lesions in human oncology FDG PET images. This study is based on a series of realistic simulated whole-body FDG images based on the XCAT model. Detection performance is evaluated with a computer-aided detection system that we are developing for whole-body PET/CT images. Detection performances achieved with these two correction methods are compared with those

  9. Effects of attenuation and scatter corrections in cat brain PET images using microPET R4 scanner

    International Nuclear Information System (INIS)

    Kim, Jin Su; Lee, Jae Sung; Lee, Jong Jin

    2006-01-01

    The aim of this study was to examine the effects of attenuation correction (AC) and scatter correction (SC) on the quantification of PET count rates. To assess the effects of AC and SC, 18 F-FDG PET images of phantom and cat brain were acquired using microPET R4 scanner. Thirty-minute transmission images using 68 Ge source and emission images after injection of FDG were acquired. PET images were reconstructed using. 2D OSEM. AC and SC were applied. Regional count rates were measured using ROls drawn on cerebral cortex including frontal, parietal, and latral temporal lobes and deep gray matter including head of caudate nucleus, putamen and thalamus for pre- and post-AC and SC images. The count rates were then normalized with the injected dose per body weight. To assess the effects of AC, count ratio of 'deep gray matter/cerebral cortex' was calculated. To assess the effects of SC, ROls were also drawn on the gray matter (GM) and white matter (WM), and contrast between them ((GM-WM)/GM) was measured. After the AC, count ratio of 'deep gray matter/cerebral cortex' was increased by 17±7%. After the SC, contrast was also increased by 12±3%. Relative count of deep gray matter and contrast between gray and white matters were increased after AC and SC, suggesting that the AC would be critical for the quantitative analysis of cat brain PET data

  10. ACE Insertion/Deletion Polymorphism and Diabetic Nephropathy: Clinical Implications of Genetic Information

    Directory of Open Access Journals (Sweden)

    Sung-Kyu Ha

    2014-01-01

    Full Text Available Approximately 20–40% of diabetic patients develop nephropathy which is the leading cause of ESRD in developed countries. The ACE I/D polymorphism is thought to be a marker for functional polymorphism which regulates circulating and tissue ACE activity. While the initial study found a protective effect of the II genotype on the development of nephropathy in IDDM patients, subsequent studies have addressed the role of ACE I/D polymorphism in the development and progression of diabetic nephropathy. RAAS blockers are the first line drugs for the treatment hypertension associated with diabetes and have been widely used in everyday clinical practice for the purpose of reducing proteinuria in patients with various renal diseases. However, the antiproteinuric effect of RAAS blockers is variable and the percentage of reducing proteinuria is in the range of 20–80%. The antiproteinuric effect of RAAS blockers may be related to a number of factors: the type or the dose of RAAS blockers, the duration of therapy, the level of sodium intake, and the type of patient’s ACE I/D genotype. Besides the nongenetic factors, drug responses, can be influenced by ACE gene polymorphism. In this review, we discuss the relationship between ACE I/D polymorphism and diabetic nephropathy and therapeutic response of RAAS blockers.

  11. Quantitative Evaluation of 2 Scatter-Correction Techniques for 18F-FDG Brain PET/MRI in Regard to MR-Based Attenuation Correction.

    Science.gov (United States)

    Teuho, Jarmo; Saunavaara, Virva; Tolvanen, Tuula; Tuokkola, Terhi; Karlsson, Antti; Tuisku, Jouni; Teräs, Mika

    2017-10-01

    In PET, corrections for photon scatter and attenuation are essential for visual and quantitative consistency. MR attenuation correction (MRAC) is generally conducted by image segmentation and assignment of discrete attenuation coefficients, which offer limited accuracy compared with CT attenuation correction. Potential inaccuracies in MRAC may affect scatter correction, because the attenuation image (μ-map) is used in single scatter simulation (SSS) to calculate the scatter estimate. We assessed the impact of MRAC to scatter correction using 2 scatter-correction techniques and 3 μ-maps for MRAC. Methods: The tail-fitted SSS (TF-SSS) and a Monte Carlo-based single scatter simulation (MC-SSS) algorithm implementations on the Philips Ingenuity TF PET/MR were used with 1 CT-based and 2 MR-based μ-maps. Data from 7 subjects were used in the clinical evaluation, and a phantom study using an anatomic brain phantom was conducted. Scatter-correction sinograms were evaluated for each scatter correction method and μ-map. Absolute image quantification was investigated with the phantom data. Quantitative assessment of PET images was performed by volume-of-interest and ratio image analysis. Results: MRAC did not result in large differences in scatter algorithm performance, especially with TF-SSS. Scatter sinograms and scatter fractions did not reveal large differences regardless of the μ-map used. TF-SSS showed slightly higher absolute quantification. The differences in volume-of-interest analysis between TF-SSS and MC-SSS were 3% at maximum in the phantom and 4% in the patient study. Both algorithms showed excellent correlation with each other with no visual differences between PET images. MC-SSS showed a slight dependency on the μ-map used, with a difference of 2% on average and 4% at maximum when a μ-map without bone was used. Conclusion: The effect of different MR-based μ-maps on the performance of scatter correction was minimal in non-time-of-flight 18 F-FDG PET

  12. The Association Analysis between ACE and ACTN3 Genes Polymorphisms and Endurance Capacity in Young Cross-Country Skiers: Longitudinal Study.

    Science.gov (United States)

    Mägi, Agnes; Unt, Eve; Prans, Ele; Raus, Liina; Eha, Jaan; Veraksitš, Alar; Kingo, Külli; Kõks, Sulev

    2016-06-01

    Endurance performance depends on the integration of several phenotypic traits influenced by multiple environmental and genetic factors. Objectives of the study were: (1) to examine the genotypic frequencies of the ACE I/D, ACTN3 R577X polymorphisms and endurance performance-related phenotypes, (2) to evaluate the dynamics of endurance performance parameters during a 5-year period in relation to ACE I/D and ACTN3 R577X genotypes in Estonian young skiers. Determination of VO2peak was performed in 58 skiers aged 15-19 years (41 males, 17 females) during a 5-year period. The control group consisted of 322 healthy non-athletic subjects (145 males, 177 females). The study groups were genotyped for the ACE I/D and ACTN3 R577X variants. Frequencies of the ACE ID and ACTN3 RR genotypes were significantly higher (p = 0.047 and p = 0.003, respectively) and the RX genotype was lower (p = 0.008) in young male skiers compared with controls. A significant relationship was found between change (Δ) of training volume and ΔVO2peak (mL·kg(-1)·min(-1)) (r = 0.475, p = 0.002). No significant main effect was detected between VO2peak (mL·kg(-1)·min(-1)) dynamics (comparison with the previous age group data) and ACE I/D and ACTN3 R577X genotypes interactions (F = 0.571, p = 0.770 and F = 0.650 and p = 0.705, respectively) in all young skiers. Study results indicated a significantly higher frequency of the ACE ID and ACTN3 RR genotypes among Estonian young male skiers compared with the male control group. Significant genotype-related differences in dynamics of VO2peak during a 5-year period were not found. In the future, longitudinal research including different gene variants may contribute to a better understanding of the nature of endurance performance. Key pointsSignificantly higher prevalence of the ACE ID and the ACTN3 RR genotypes were found among Estonian young male skiers compared with the male control group, which may be an advantage for the explosive speed and power

  13. Whole-body bone segmentation from MRI for PET/MRI attenuation correction using shape-based averaging

    DEFF Research Database (Denmark)

    Arabi, Hossein; Zaidi, H.

    2016-01-01

    Purpose: The authors evaluate the performance of shape-based averaging (SBA) technique for whole-body bone segmentation from MRI in the context of MRI-guided attenuation correction (MRAC) in hybrid PET/MRI. To enhance the performance of the SBA scheme, the authors propose to combine it with stati......Purpose: The authors evaluate the performance of shape-based averaging (SBA) technique for whole-body bone segmentation from MRI in the context of MRI-guided attenuation correction (MRAC) in hybrid PET/MRI. To enhance the performance of the SBA scheme, the authors propose to combine...... it with statistical atlas fusion techniques. Moreover, a fast and efficient shape comparisonbased atlas selection scheme was developed and incorporated into the SBA method. Methods: Clinical studies consisting of PET/CT and MR images of 21 patients were used to assess the performance of the SBA method. In addition...... voting (MV) atlas fusion scheme was also evaluated as a conventional and commonly used method. MRI-guided attenuation maps were generated using the different segmentation methods. Thereafter, quantitative analysis of PET attenuation correction was performed using CT-based attenuation correction...

  14. Single nucleotide polymorphisms of the angiotensin-converting enzyme (ACE) gene are associated with essential hypertension and increased ACE enzyme levels in Mexican individuals.

    Science.gov (United States)

    Martínez-Rodríguez, Nancy; Posadas-Romero, Carlos; Villarreal-Molina, Teresa; Vallejo, Maite; Del-Valle-Mondragón, Leonardo; Ramírez-Bello, Julian; Valladares, Adan; Cruz-López, Miguel; Vargas-Alarcón, Gilberto

    2013-01-01

    To explore the role of the ACE gene polymorphisms in the risk of essential hypertension in Mexican Mestizo individuals and evaluate the correlation between these polymorphisms and the serum ACE levels. Nine ACE gene polymorphisms were genotyped by 5' exonuclease TaqMan genotyping assays and polymerase chain reaction (PCR) in 239 hypertensive and 371 non- hypertensive Mexican individuals. Haplotypes were constructed after linkage disequilibrium analysis. ACE serum levels were determined in selected individuals according to different haplotypes. Under a dominant model, rs4291 rs4335, rs4344, rs4353, rs4362, and rs4363 polymorphisms were associated with an increased risk of hypertension after adjusting for age, gender, BMI, triglycerides, alcohol consumption, and smoking. Five polymorphisms (rs4335, rs4344, rs4353, rs4362 and rs4363) were in strong linkage disequilibrium and were included in four haplotypes: H1 (AAGCA), H2 (GGATG), H3 (AGATG), and H4 (AGACA). Haplotype H1 was associated with decreased risk of hypertension, while haplotype H2 was associated with an increased risk of hypertension (OR = 0.77, P = 0.023 and OR = 1.41, P = 0.004 respectively). According to the codominant model, the H2/H2 and H1/H2 haplotype combinations were significantly associated with risk of hypertension after adjusted by age, gender, BMI, triglycerides, alcohol consumption, and smoking (OR = 2.0; P = 0.002 and OR = 2.09; P = 0.011, respectively). Significant elevations in serum ACE concentrations were found in individuals with the H2 haplotype (H2/H2 and H2/H1) as compared to H1/H1 individuals (P = 0.0048). The results suggest that single nucleotide polymorphisms and the "GGATG" haplotype of the ACE gene are associated with the development of hypertension and with increased ACE enzyme levels.

  15. Magnetic resonance imaging-guided attenuation correction of positron emission tomography data in PET/MRI

    Science.gov (United States)

    Izquierdo-Garcia, David; Catana, Ciprian

    2018-01-01

    Synopsis Attenuation correction (AC) is one of the most important challenges in the recently introduced combined positron emission tomography/magnetic resonance imaging (PET/MR) scanners. PET/MR AC (MR-AC) approaches aim to develop methods that allow accurate estimation of the linear attenuation coefficients (LACs) of the tissues and other components located in the PET field of view (FoV). MR-AC methods can be divided into three main categories: segmentation-, atlas- and PET-based. This review aims to provide a comprehensive list of the state of the art MR-AC approaches as well as their pros and cons. The main sources of artifacts such as body-truncation, metallic implants and hardware correction will be presented. Finally, this review will discuss the current status of MR-AC approaches for clinical applications. PMID:26952727

  16. Anatomically guided voxel-based partial volume effect correction in brain PET : Impact of MRI segmentation

    NARCIS (Netherlands)

    Gutierrez, Daniel; Montandon, Marie-Louise; Assal, Frederic; Allaoua, Mohamed; Ratib, Osman; Loevblad, Karl-Olof; Zaidi, Habib

    2012-01-01

    Partial volume effect is still considered one of the main limitations in brain PET imaging given the limited spatial resolution of current generation PET scanners. The accuracy of anatomically guided partial volume effect correction (PVC) algorithms in brain PET is largely dependent on the

  17. MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction

    Science.gov (United States)

    Fei, Baowei; Yang, Xiaofeng; Nye, Jonathon A.; Aarsvold, John N.; Raghunath, Nivedita; Cervo, Morgan; Stark, Rebecca; Meltzer, Carolyn C.; Votaw, John R.

    2012-01-01

    Purpose: Combined MR/PET is a relatively new, hybrid imaging modality. A human MR/PET prototype system consisting of a Siemens 3T Trio MR and brain PET insert was installed and tested at our institution. Its present design does not offer measured attenuation correction (AC) using traditional transmission imaging. This study is the development of quantification tools including MR-based AC for quantification in combined MR/PET for brain imaging. Methods: The developed quantification tools include image registration, segmentation, classification, and MR-based AC. These components were integrated into a single scheme for processing MR/PET data. The segmentation method is multiscale and based on the Radon transform of brain MR images. It was developed to segment the skull on T1-weighted MR images. A modified fuzzy C-means classification scheme was developed to classify brain tissue into gray matter, white matter, and cerebrospinal fluid. Classified tissue is assigned an attenuation coefficient so that AC factors can be generated. PET emission data are then reconstructed using a three-dimensional ordered sets expectation maximization method with the MR-based AC map. Ten subjects had separate MR and PET scans. The PET with [11C]PIB was acquired using a high-resolution research tomography (HRRT) PET. MR-based AC was compared with transmission (TX)-based AC on the HRRT. Seventeen volumes of interest were drawn manually on each subject image to compare the PET activities between the MR-based and TX-based AC methods. Results: For skull segmentation, the overlap ratio between our segmented results and the ground truth is 85.2 ± 2.6%. Attenuation correction results from the ten subjects show that the difference between the MR and TX-based methods was <6.5%. Conclusions: MR-based AC compared favorably with conventional transmission-based AC. Quantitative tools including registration, segmentation, classification, and MR-based AC have been developed for use in combined MR/PET

  18. MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction

    Energy Technology Data Exchange (ETDEWEB)

    Fei, Baowei, E-mail: bfei@emory.edu [Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1841 Clifton Road Northeast, Atlanta, Georgia 30329 (United States); Department of Biomedical Engineering, Emory University and Georgia Institute of Technology, Atlanta, Georgia 30322 (United States); Department of Mathematics and Computer Sciences, Emory University, Atlanta, Georgia 30322 (United States); Yang, Xiaofeng; Nye, Jonathon A.; Raghunath, Nivedita; Votaw, John R. [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30329 (United States); Aarsvold, John N. [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30329 (United States); Nuclear Medicine Service, Atlanta Veterans Affairs Medical Center, Atlanta, Georgia 30033 (United States); Cervo, Morgan; Stark, Rebecca [The Medical Physics Graduate Program in the George W. Woodruff School, Georgia Institute of Technology, Atlanta, Georgia 30332 (United States); Meltzer, Carolyn C. [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30329 (United States); Department of Neurology and Department of Psychiatry and Behavior Sciences, Emory University School of Medicine, Atlanta, Georgia 30322 (United States)

    2012-10-15

    Purpose: Combined MR/PET is a relatively new, hybrid imaging modality. A human MR/PET prototype system consisting of a Siemens 3T Trio MR and brain PET insert was installed and tested at our institution. Its present design does not offer measured attenuation correction (AC) using traditional transmission imaging. This study is the development of quantification tools including MR-based AC for quantification in combined MR/PET for brain imaging. Methods: The developed quantification tools include image registration, segmentation, classification, and MR-based AC. These components were integrated into a single scheme for processing MR/PET data. The segmentation method is multiscale and based on the Radon transform of brain MR images. It was developed to segment the skull on T1-weighted MR images. A modified fuzzy C-means classification scheme was developed to classify brain tissue into gray matter, white matter, and cerebrospinal fluid. Classified tissue is assigned an attenuation coefficient so that AC factors can be generated. PET emission data are then reconstructed using a three-dimensional ordered sets expectation maximization method with the MR-based AC map. Ten subjects had separate MR and PET scans. The PET with [{sup 11}C]PIB was acquired using a high-resolution research tomography (HRRT) PET. MR-based AC was compared with transmission (TX)-based AC on the HRRT. Seventeen volumes of interest were drawn manually on each subject image to compare the PET activities between the MR-based and TX-based AC methods. Results: For skull segmentation, the overlap ratio between our segmented results and the ground truth is 85.2 ± 2.6%. Attenuation correction results from the ten subjects show that the difference between the MR and TX-based methods was <6.5%. Conclusions: MR-based AC compared favorably with conventional transmission-based AC. Quantitative tools including registration, segmentation, classification, and MR-based AC have been developed for use in combined MR/PET.

  19. MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction

    International Nuclear Information System (INIS)

    Fei, Baowei; Yang, Xiaofeng; Nye, Jonathon A.; Raghunath, Nivedita; Votaw, John R.; Aarsvold, John N.; Cervo, Morgan; Stark, Rebecca; Meltzer, Carolyn C.

    2012-01-01

    Purpose: Combined MR/PET is a relatively new, hybrid imaging modality. A human MR/PET prototype system consisting of a Siemens 3T Trio MR and brain PET insert was installed and tested at our institution. Its present design does not offer measured attenuation correction (AC) using traditional transmission imaging. This study is the development of quantification tools including MR-based AC for quantification in combined MR/PET for brain imaging. Methods: The developed quantification tools include image registration, segmentation, classification, and MR-based AC. These components were integrated into a single scheme for processing MR/PET data. The segmentation method is multiscale and based on the Radon transform of brain MR images. It was developed to segment the skull on T1-weighted MR images. A modified fuzzy C-means classification scheme was developed to classify brain tissue into gray matter, white matter, and cerebrospinal fluid. Classified tissue is assigned an attenuation coefficient so that AC factors can be generated. PET emission data are then reconstructed using a three-dimensional ordered sets expectation maximization method with the MR-based AC map. Ten subjects had separate MR and PET scans. The PET with ["1"1C]PIB was acquired using a high-resolution research tomography (HRRT) PET. MR-based AC was compared with transmission (TX)-based AC on the HRRT. Seventeen volumes of interest were drawn manually on each subject image to compare the PET activities between the MR-based and TX-based AC methods. Results: For skull segmentation, the overlap ratio between our segmented results and the ground truth is 85.2 ± 2.6%. Attenuation correction results from the ten subjects show that the difference between the MR and TX-based methods was <6.5%. Conclusions: MR-based AC compared favorably with conventional transmission-based AC. Quantitative tools including registration, segmentation, classification, and MR-based AC have been developed for use in combined MR/PET.

  20. The Metabolic Response of Skeletal Muscle to Endurance Exercise Is Modified by the ACE-I/D Gene Polymorphism and Training State

    Directory of Open Access Journals (Sweden)

    Paola Valdivieso

    2017-12-01

    Full Text Available The insertion/deletion polymorphism in the gene for the regulator of vascular tone, angiotensin-converting enzyme (ACE, is the prototype of a genetic influence on physical fitness and this involves an influence on capillary supply lines and dependent aerobic metabolism in skeletal muscle. The respective interaction of ACE-I/D genotype and training status on local metabolic and angiogenic reactions in exercised muscle is not known. Toward this end we characterized the metabolomic and angiogenic response in knee extensor muscle, m. vastus lateralis, in 18 untrained and 34 endurance-trained (physically active, V˙O2max > 50 mL min−1 kg−1 white British men to an exhaustive bout of one-legged cycling exercise. We hypothesized that training status and ACE-I/D genotype affect supply-related muscle characteristics of exercise performance in correspondence to ACE expression and angiotensin 2 levels. ACE-I/D genotype and training status developed an interaction effect on the cross-sectional area (CSA of m. vastus lateralis and mean CSA of slow type fibers, which correlated with peak power output (r ≥ 0.44. Genotype × training interactions in muscle also resolved for exercise-induced alterations of 22 metabolites, 8 lipids, glycogen concentration (p = 0.016, ACE transcript levels (p = 0.037, and by trend for the pro-angiogenic factor tenascin-C post exercise (p = 0.064. Capillary density (p = 0.001, capillary-to-fiber ratio (p = 0.010, systolic blood pressure (p = 0.014, and exercise-induced alterations in the pro-angiogenic protein VEGF (p = 0.043 depended on the ACE-I/D genotype alone. Our observations indicate that variability in aerobic performance in the studied subjects was in part reflected by an ACE-I/D-genotype-modulated metabolic phenotype of a major locomotor muscle. Repeated endurance exercise appeared to override this genetic influence in skeletal muscle by altering the ACE-related metabolic response and molecular aspects of the

  1. The Metabolic Response of Skeletal Muscle to Endurance Exercise Is Modified by the ACE-I/D Gene Polymorphism and Training State.

    Science.gov (United States)

    Valdivieso, Paola; Vaughan, David; Laczko, Endre; Brogioli, Michael; Waldron, Sarah; Rittweger, Jörn; Flück, Martin

    2017-01-01

    The insertion/deletion polymorphism in the gene for the regulator of vascular tone, angiotensin-converting enzyme (ACE), is the prototype of a genetic influence on physical fitness and this involves an influence on capillary supply lines and dependent aerobic metabolism in skeletal muscle. The respective interaction of ACE-I/D genotype and training status on local metabolic and angiogenic reactions in exercised muscle is not known. Toward this end we characterized the metabolomic and angiogenic response in knee extensor muscle, m. vastus lateralis , in 18 untrained and 34 endurance-trained (physically active, [Formula: see text]O2max > 50 mL min -1 kg -1 ) white British men to an exhaustive bout of one-legged cycling exercise. We hypothesized that training status and ACE-I/D genotype affect supply-related muscle characteristics of exercise performance in correspondence to ACE expression and angiotensin 2 levels. ACE-I/D genotype and training status developed an interaction effect on the cross-sectional area (CSA) of m. vastus lateralis and mean CSA of slow type fibers, which correlated with peak power output ( r ≥ 0.44). Genotype × training interactions in muscle also resolved for exercise-induced alterations of 22 metabolites, 8 lipids, glycogen concentration ( p = 0.016), ACE transcript levels ( p = 0.037), and by trend for the pro-angiogenic factor tenascin-C post exercise ( p = 0.064). Capillary density ( p = 0.001), capillary-to-fiber ratio ( p = 0.010), systolic blood pressure ( p = 0.014), and exercise-induced alterations in the pro-angiogenic protein VEGF ( p = 0.043) depended on the ACE-I/D genotype alone. Our observations indicate that variability in aerobic performance in the studied subjects was in part reflected by an ACE-I/D-genotype-modulated metabolic phenotype of a major locomotor muscle. Repeated endurance exercise appeared to override this genetic influence in skeletal muscle by altering the ACE-related metabolic response and molecular aspects

  2. Partial volume effect-corrected FDG PET and grey matter volume loss in patients with mild Alzheimer's disease

    International Nuclear Information System (INIS)

    Samuraki, Miharu; Yanase, Daisuke; Yamada, Masahito; Matsunari, Ichiro; Chen, Wei-Ping; Yajima, Kazuyoshi; Fujikawa, Akihiko; Takeda, Nozomi; Nishimura, Shintaro; Matsuda, Hiroshi

    2007-01-01

    Although 18 F-fluorodeoxyglucose (FDG) PET is an established imaging technique to assess brain glucose utilisation, accurate measurement of tracer concentration is confounded by the presence of partial volume effect (PVE) due to the limited spatial resolution of PET, which is particularly true in atrophic brains such as those encountered in patients with Alzheimer's disease (AD). Our aim was to investigate the effects of PVE correction on FDG PET in conjunction with voxel-based morphometry (VBM) in patients with mild AD. Thirty-nine AD patients and 73 controls underwent FDG PET and MRI. The PVE-corrected grey matter PET images were obtained using an MRI-based three-compartment method. Additionally, the results of PET were compared with grey matter loss detected by VBM. Before PVE correction, reduced FDG uptake was observed in posterior cingulate gyri (PCG) and parieto-temporal lobes (PTL) in AD patients, which persisted after PVE correction. Notably, PVE correction revealed relatively preserved FDG uptake in hippocampal areas, despite the grey matter loss in medial temporal lobe (MTL) revealed by VBM. FDG uptake in PCG and PTL is reduced in AD regardless of whether or not PVE correction is applied, supporting the notion that the reduced FDG uptake in these areas is not the result of atrophy. Furthermore, FDG uptake by grey matter tissue in the MTL, including hippocampal areas, is relatively preserved, suggesting that compensatory mechanisms may play a role in patients with mild AD. (orig.)

  3. The association of ACE gene polymorphism with diabetic kidney disease and renoprotective efficacy of valsartan.

    Science.gov (United States)

    Wang, Yuying; Peng, Wen; Zhang, Xiaoxue; Qiao, Huibo; Wang, Li; Xu, Zhigang; Wu, Chenguang

    2016-07-01

    To investigate the associations between the insertion/deletion (I/D) polymorphisms in the angiotensin converting enzyme (ACE) gene and susceptibility to diabetic kidney disease (DKD); and the efficacy of valsartan in reducing the urine protein in Type 2 diabetes mellitus (T2DM) patients. We enrolled 128 T2DM patients in this study, including 54 cases with DKD (DKD+) and 74 controls (DKD-). The ACE polymorphism was assayed by polymerase chain reaction (PCR), and the genotype distribution and allele frequency were analyzed. The DKD+ group was subdivided into the DD, ID and II subgroups, based on their genotypes. In addition, patients with DKD received valsartan treatment for 12 weeks. We determined changes in the urinary albumin to creatinine ratio (ACR) and serum creatinine (SCr). The frequencies of the genotypes DD and ID were higher in the DKD+ than in the DKD- group. The frequency of allele D was higher, and of allele I was lower, in the DKD+ than in DKD- group (p ACE I/D polymorphism was associated with onset of DKD. Furthermore, the ACE I/D polymorphism influenced the renoprotective response to valsartan: Patients with the DD genotype benefitted the most from this treatment. © The Author(s) 2016.

  4. Assessment of the relationship between ACE I/D gene polymorphism and renal allograft survival.

    Science.gov (United States)

    Yang, Chun-Hua; Lu, Yi; Chen, Xue-Xia; Xian, Wen-Feng; Tu, Wei-Feng; Li, Hong-Yan

    2015-12-01

    The relationship between the angiotensin-converting enzyme (ACE) insertion/deletion (I/D) gene polymorphism and renal allograft survival after renal transplantation from the published reports are still debatable. This study was performed to evaluate the relationship between the ACE I/D gene polymorphism and renal allograft survival after renal transplantation using meta-analysis. Eligible studies were identified from PubMed and Cochrane Library on 1 November 2014, and eligible studies were recruited and synthesized using a meta-analysis methodology. Twelve investigations were included in this meta-analysis for the assessment of the relationship between the ACE I/D gene polymorphism and renal allograft survival. In this meta-analysis, the ACE I/D gene polymorphism was not associated with renal allograft survival after renal transplantation for overall populations, Caucasians, Brazilians and Africans. Interestingly, the ACE D allele and DD genotype were associated with renal allograft survival after renal transplantation in the Asian population. ACE D allele and DD genotype were associated with renal allograft survival after renal transplantation in the Asian population. However, more studies should be performed to confirm this association. © The Author(s) 2015.

  5. Field of view extension and truncation correction for MR-based human attenuation correction in simultaneous MR/PET imaging

    International Nuclear Information System (INIS)

    Blumhagen, Jan O.; Ladebeck, Ralf; Fenchel, Matthias; Braun, Harald; Quick, Harald H.; Faul, David; Scheffler, Klaus

    2014-01-01

    Purpose: In quantitative PET imaging, it is critical to accurately measure and compensate for the attenuation of the photons absorbed in the tissue. While in PET/CT the linear attenuation coefficients can be easily determined from a low-dose CT-based transmission scan, in whole-body MR/PET the computation of the linear attenuation coefficients is based on the MR data. However, a constraint of the MR-based attenuation correction (AC) is the MR-inherent field-of-view (FoV) limitation due to static magnetic field (B 0 ) inhomogeneities and gradient nonlinearities. Therefore, the MR-based human AC map may be truncated or geometrically distorted toward the edges of the FoV and, consequently, the PET reconstruction with MR-based AC may be biased. This is especially of impact laterally where the patient arms rest beside the body and are not fully considered. Methods: A method is proposed to extend the MR FoV by determining an optimal readout gradient field which locally compensates B 0 inhomogeneities and gradient nonlinearities. This technique was used to reduce truncation in AC maps of 12 patients, and the impact on the PET quantification was analyzed and compared to truncated data without applying the FoV extension and additionally to an established approach of PET-based FoV extension. Results: The truncation artifacts in the MR-based AC maps were successfully reduced in all patients, and the mean body volume was thereby increased by 5.4%. In some cases large patient-dependent changes in SUV of up to 30% were observed in individual lesions when compared to the standard truncated attenuation map. Conclusions: The proposed technique successfully extends the MR FoV in MR-based attenuation correction and shows an improvement of PET quantification in whole-body MR/PET hybrid imaging. In comparison to the PET-based completion of the truncated body contour, the proposed method is also applicable to specialized PET tracers with little uptake in the arms and might reduce the

  6. Genetic associations of body composition, flexibility and injury risk with ACE, ACTN3 and COL5A1 polymorphisms in Korean ballerinas

    Science.gov (United States)

    Kim, Jun Ho; Jung, Eun Sun; Kim, Chul-Hyun; Youn, Hyeon; Kim, Hwa Rye

    2014-01-01

    [Purpose] The purpose of this study was to exam the association of body composition, flexibility, and injury risk to genetic polymorphisms including ACE ID, ACTN3 RX, and COL5A1 polymorphisms in ballet dancers in Korea. [Methods] For the purpose of this study, elite ballerinas (n = 97) and normal female adults (n = 203) aged 18 to 39 were recruited and these participants were tested for body weight, height, body fat, fat free mass, flexibility, injury risks on the joints and gene polymorphisms (ACE, ACTN3, COL5A1 polymorphism). [Results] As results, the ACE DD genotype in ballerinas was associated with higher body fat and percentage of body fat than the ACE II and ID genotypes (p sports injuries, the ankle injury of the XX-genotyped ballerinas was in significantly more prevalence than the RR and XX-genotyped ballerinas (p < 0.05). According to the odd ratio analysis, XX-genotyped ballerinas have the injury risk on the ankle about 4.7 (95% CI: 1.6~13.4, p < 0.05) times more than the RR and RX-genotyped ballerinas. Meanwhile, the COL5A1 polymorphism in ballerinas has no association with any factors including flexibility and injury risks. [Conclusion] In conclusion, ACE polymorphism and ACTN3 polymorphism were associated with ballerinas' performance capacity; COL5A1 was not associated with any factors of performance of Ballerinas. The results suggested that the ACE DD genotype is associated with high body fat, the ACTN3 XX genotype is associated with low fat-free mass, low flexibility, and higher risk of ankle-joint injury. PMID:25566457

  7. MRI-guided attenuation correction in whole-body PET/MR. Assessment of the effect of bone attenuation

    International Nuclear Information System (INIS)

    Akbarzadeh, A.; Ay, M.R.; Ahmadian, A.; Riahi Alam, N.; Zaidi, H.

    2013-01-01

    Hybrid positron emission tomography (PET)/MRI presents many advantages in comparison with its counterpart PET/CT in terms of improved soft-tissue contrast, decrease in radiation exposure, and truly simultaneous and multi-parametric imaging capabilities. However, the lack of well-established methodology for MR-based attenuation correction is hampering further development and wider acceptance of this technology. We assess the impact of ignoring bone attenuation and using different tissue classes for generation of the attenuation map on the accuracy of attenuation correction of PET data. This work was performed using simulation studies based on the XCAT phantom and clinical input data. For the latter, PET and CT images of patients were used as input for the analytic simulation model using realistic activity distributions where CT-based attenuation correction was utilized as reference for comparison. For both phantom and clinical studies, the reference attenuation map was classified into various numbers of tissue classes to produce three (air, soft tissue and lung), four (air, lungs, soft tissue and cortical bones) and five (air, lungs, soft tissue, cortical bones and spongeous bones) class attenuation maps. The phantom studies demonstrated that ignoring bone increases the relative error by up to 6.8% in the body and up to 31.0% for bony regions. Likewise, the simulated clinical studies showed that the mean relative error reached 15% for lesions located in the body and 30.7% for lesions located in bones, when neglecting bones. These results demonstrate an underestimation of about 30% of tracer uptake when neglecting bone, which in turn imposes substantial loss of quantitative accuracy for PET images produced by hybrid PET/MRI systems. Considering bones in the attenuation map will considerably improve the accuracy of MR-guided attenuation correction in hybrid PET/MR to enable quantitative PET imaging on hybrid PET/MR technologies. (author)

  8. PET/MR brain imaging: evaluation of clinical UTE-based attenuation correction

    International Nuclear Information System (INIS)

    Aasheim, Lars Birger; Karlberg, Anna; Goa, Paal Erik; Haaberg, Asta; Soerhaug, Sveinung; Fagerli, Unn-Merete; Eikenes, Live

    2015-01-01

    One of the greatest challenges in PET/MR imaging is that of accurate MR-based attenuation correction (AC) of the acquired PET data, which must be solved if the PET/MR modality is to reach its full potential. The aim of this study was to investigate the performance of Siemens' most recent version (VB20P) of MR-based AC of head PET data, by comparing it to CT-based AC. Methods: 18 F-FDG PET data from seven lymphoma and twelve lung cancer patients examined with a Biograph mMR PET/MR system were reconstructed with both CT-based and MR-based AC, avoiding sources of error arising when comparing PET data from different systems. The resulting images were compared quantitatively by measuring changes in mean SUV in ten different brain regions in both hemispheres, as well as the brainstem. In addition, the attenuation maps (μ maps) were compared regarding volume and localization of cranial bone. The UTE μ maps clearly overestimate the amount of bone in the neck, while slightly underestimating the amount of bone in the cranium, and the localization of bone in the cranial region also differ from the CT μ maps. In air/tissue interfaces in the sinuses and ears, the MRAC method struggles to correctly classify the different tissues. The misclassification of tissue is most likely caused by a combination of artefacts and the insufficiency of the UTE method to accurately separate bone. Quantitatively, this results in a combination of overestimation (0.5-3.6 %) and underestimation (2.7-5.2 %) of PET activity throughout the brain, depending on the proximity to the inaccurate regions. Our results indicate that the performance of the UTE method as implemented in VB20P is close to the theoretical maximum of such an MRAC method in the brain, while it does not perform satisfactorily in the neck or face/nasal area. Further improvement of the UTE MRAC or other available methods for more accurate segmentation of bone should be incorporated. (orig.)

  9. Magnetic resonance imaging-guided attenuation correction of positron emission tomography data in PET/MRI

    OpenAIRE

    Izquierdo-Garcia, David; Catana, Ciprian

    2016-01-01

    Attenuation correction (AC) is one of the most important challenges in the recently introduced combined positron emission tomography/magnetic resonance imaging (PET/MR) scanners. PET/MR AC (MR-AC) approaches aim to develop methods that allow accurate estimation of the linear attenuation coefficients (LACs) of the tissues and other components located in the PET field of view (FoV). MR-AC methods can be divided into three main categories: segmentation-, atlas- and PET-based. This review aims to...

  10. ACE genotype, phenotype and all-cause mortality in different cohorts of patients with type 1 diabetes

    DEFF Research Database (Denmark)

    Færch, Louise H; Sejling, Anne-Sophie; Lajer, Maria

    2015-01-01

    AIMS: Carrying the D-allele of the angiotensin-converting enzyme (ACE) I/D polymorphism and high ACE activity are prognostic factors in diabetic nephropathy, which predicts mortality in type 1 diabetes. We studied the association between the ACE D-allele and ACE phenotype and long-term all-cause ...

  11. The impact of ACE gene polymorphism on the incidence and phenotype of sarcoidosis in rural and urban settings.

    Science.gov (United States)

    Kieszko, Robert; Krawczyk, Paweł; Powrózek, Tomasz; Szudy-Szczyrek, Aneta; Szczyrek, Michał; Homa, Iwona; Daniluk, Jadwiga; Milanowski, Janusz

    2016-12-01

    Sarcoidosis is a multisystem granulomatous disease of unknown etiology. Current theory on the etiology of this disease involves participation of genetic factors and unknown antigens present in the patients' environment. The aim of the study was to evaluate the prevalence of different polymorphic forms of the ACE gene in healthy individuals and sarcoidosis patients, and to estimate the risk of sarcoidosis in carriers of different ACE genotypes living in rural and urban settings. The study group included 180 patients with pulmonary sarcoidosis. Assessment of the disease was based on clinical features, laboratory and imaging examinations, as well as bronchoscopy with bronchoalveolar lavage (BAL). ACE gene polymorphism was examined in DNA isolated from peripheral blood or BAL fluid (BALF) leukocytes. Incidence of sarcoidosis was not influenced by gender, age or place of residence of the patients. There were no differences in the frequency of particular genotypes in patients with sarcoidosis and in healthy individuals. The risk of disease did not depend on the ACE gene polymorphism. There were no differences in the frequencies of the different genotypes and alleles of the ACE gene in patients with sarcoidosis divided by gender, age and place of residence or by clinical manifestation of sarcoidosis. Our results do not support the previous concept which suggested a higher incidence of sarcoidosis in individuals living in rural areas and in carriers of selected ACE genotypes. It is possible that this is related to the changing environment of rural areas, increasing urbanization and pollution.

  12. Event-based motion correction for PET transmission measurements with a rotating point source

    International Nuclear Information System (INIS)

    Zhou, Victor W; Kyme, Andre Z; Meikle, Steven R; Fulton, Roger

    2011-01-01

    Accurate attenuation correction is important for quantitative positron emission tomography (PET) studies. When performing transmission measurements using an external rotating radioactive source, object motion during the transmission scan can distort the attenuation correction factors computed as the ratio of the blank to transmission counts, and cause errors and artefacts in reconstructed PET images. In this paper we report a compensation method for rigid body motion during PET transmission measurements, in which list mode transmission data are motion corrected event-by-event, based on known motion, to ensure that all events which traverse the same path through the object are recorded on a common line of response (LOR). As a result, the motion-corrected transmission LOR may record a combination of events originally detected on different LORs. To ensure that the corresponding blank LOR records events from the same combination of contributing LORs, the list mode blank data are spatially transformed event-by-event based on the same motion information. The number of counts recorded on the resulting blank LOR is then equivalent to the number of counts that would have been recorded on the corresponding motion-corrected transmission LOR in the absence of any attenuating object. The proposed method has been verified in phantom studies with both stepwise movements and continuous motion. We found that attenuation maps derived from motion-corrected transmission and blank data agree well with those of the stationary phantom and are significantly better than uncorrected attenuation data.

  13. Association Between ACE Gene Polymorphism and QT Dispersion in Patients with Acute Myocardial Infarction.

    Science.gov (United States)

    Karahan, Zulkuf; Ugurlu, Murat; Ucaman, Berzal; Veysel Ulug, Ali; Kaya, Ilyas; Cevik, Kemal; Sahin Adiyaman, Mehmet; Oztürk, Onder; Iyem, Hikmet; Ozdemir, Ferit

    2016-01-01

    Angiotensin converting enzyme (ACE) gene polymorphism is associated with high renin-angiotensin system causing myocardial fibrosis and ventricular repolarization abnormality. Based on these findings, this study was designed to determine the association between ACE gene insertion/deletion (I/D) polymorphism and QT dispersion after acute myocardial infarction (MI). The study included 108 patients with acute MI. Blood samples were obtained from all the patients for genomic DNA analysis. ECGs were recorded at baseline and at the end of a 6-month follow up. The OT dispersion was manually calculated. The mean age of the patients was 57.5 ±9.9 years (ranging from 36 to 70). The patients with DD genotype showed longer QT dispersion than patients with II or DI genotype at the baseline, while at the end of the six-month follow up the patients with DI genotype showed longer QT dispersion than patients with DD or II genotypes. However, the magnitude of the QT dispersion prolongation was higher in patients carrying the ACE D allele than patients who were not carrying it, at baseline and at the end of six-month follow up (52.5 ±2.6 msn vs. 47.5±2.1 msn at baseline, 57±3.2 msn vs. 53±2.6 msn in months, P: 0.428 and P: 0.613, respectively). Carriers of the D allele of ACE gene I/D polymorphism may be associated with QT dispersion prolongation in patients with MI.An interaction of QT dispersion and ACE gene polymorphism may be associated with an elevation of serum type I-C terminal pro-collagen concentration, possibly leading to myocardial fibrosis, and increased action potential duration.

  14. ACTN3 R577X and ACE I/D gene variants influence performance in elite sprinters: a multi-cohort study.

    Science.gov (United States)

    Papadimitriou, Ioannis D; Lucia, Alejandro; Pitsiladis, Yannis P; Pushkarev, Vladimir P; Dyatlov, Dmitry A; Orekhov, Evgeniy F; Artioli, Guilherme G; Guilherme, João Paulo L F; Lancha, Antonio H; Ginevičienė, Valentina; Cieszczyk, Pawel; Maciejewska-Karlowska, Agnieszka; Sawczuk, Marek; Muniesa, Carlos A; Kouvatsi, Anastasia; Massidda, Myosotis; Calò, Carla Maria; Garton, Fleur; Houweling, Peter J; Wang, Guan; Austin, Krista; Druzhevskaya, Anastasiya M; Astratenkova, Irina V; Ahmetov, Ildus I; Bishop, David J; North, Kathryn N; Eynon, Nir

    2016-04-13

    To date, studies investigating the association between ACTN3 R577X and ACE I/D gene variants and elite sprint/power performance have been limited by small cohorts from mixed sport disciplines, without quantitative measures of performance. To examine the association between these variants and sprint time in elite athletes. We collected a total of 555 best personal 100-, 200-, and 400-m times of 346 elite sprinters in a large cohort of elite Caucasian or African origin sprinters from 10 different countries. Sprinters were genotyped for ACTN3 R577X and ACE ID variants. On average, male Caucasian sprinters with the ACTN3 577RR or the ACE DD genotype had faster best 200-m sprint time than their 577XX (21.19 ± 0.53 s vs. 21.86 ± 0.54 s, p = 0.016) and ACE II (21.33 ± 0.56 vs. 21.93 ± 0.67 sec, p = 0.004) counterparts and only one case of ACE II, and no cases of ACTN3 577XX, had a faster 200-m time than the 2012 London Olympics qualifying (vs. 12 qualified sprinters with 577RR or 577RX genotype). Caucasian sprinters with the ACE DD genotype had faster best 400-m sprint time than their ACE II counterparts (46.94 ± 1.19 s vs. 48.50 ± 1.07 s, p = 0.003). Using genetic models we found that the ACTN3 577R allele and ACE D allele dominant model account for 0.92 % and 1.48 % of sprint time variance, respectively. Despite sprint performance relying on many gene variants and environment, the % sprint time variance explained by ACE and ACTN3 is substantial at the elite level and might be the difference between a world record and only making the final.

  15. Markov random field and Gaussian mixture for segmented MRI-based partial volume correction in PET

    International Nuclear Information System (INIS)

    Bousse, Alexandre; Thomas, Benjamin A; Erlandsson, Kjell; Hutton, Brian F; Pedemonte, Stefano; Ourselin, Sébastien; Arridge, Simon

    2012-01-01

    In this paper we propose a segmented magnetic resonance imaging (MRI) prior-based maximum penalized likelihood deconvolution technique for positron emission tomography (PET) images. The model assumes the existence of activity classes that behave like a hidden Markov random field (MRF) driven by the segmented MRI. We utilize a mean field approximation to compute the likelihood of the MRF. We tested our method on both simulated and clinical data (brain PET) and compared our results with PET images corrected with the re-blurred Van Cittert (VC) algorithm, the simplified Guven (SG) algorithm and the region-based voxel-wise (RBV) technique. We demonstrated our algorithm outperforms the VC algorithm and outperforms SG and RBV corrections when the segmented MRI is inconsistent (e.g. mis-segmentation, lesions, etc) with the PET image. (paper)

  16. The Association Analysis between ACE and ACTN3 Genes Polymorphisms and Endurance Capacity in Young Cross-Country Skiers: Longitudinal Study

    Directory of Open Access Journals (Sweden)

    Agnes Mägi, Eve Unt, Ele Prans, Liina Raus, Jaan Eha, Alar Veraksitš, Külli Kingo, Sulev Kõks

    2016-06-01

    Full Text Available Endurance performance depends on the integration of several phenotypic traits influenced by multiple environmental and genetic factors. Objectives of the study were: (1 to examine the genotypic frequencies of the ACE I/D, ACTN3 R577X polymorphisms and endurance performance-related phenotypes, (2 to evaluate the dynamics of endurance performance parameters during a 5-year period in relation to ACE I/D and ACTN3 R577X genotypes in Estonian young skiers. Determination of VO2peak was performed in 58 skiers aged 15-19 years (41 males, 17 females during a 5-year period. The control group consisted of 322 healthy non-athletic subjects (145 males, 177 females. The study groups were genotyped for the ACE I/D and ACTN3 R577X variants. Frequencies of the ACE ID and ACTN3 RR genotypes were significantly higher (p = 0.047 and p = 0.003, respectively and the RX genotype was lower (p = 0.008 in young male skiers compared with controls. A significant relationship was found between change (Δ of training volume and ΔVO2peak (mL·kg-1·min-1 (r = 0.475, p = 0.002. No significant main effect was detected between VO2peak (mL·kg-1·min-1 dynamics (comparison with the previous age group data and ACE I/D and ACTN3 R577X genotypes interactions (F = 0.571, p = 0.770 and F = 0.650 and p = 0.705, respectively in all young skiers. Study results indicated a significantly higher frequency of the ACE ID and ACTN3 RR genotypes among Estonian young male skiers compared with the male control group. Significant genotype-related differences in dynamics of VO2peak during a 5-year period were not found. In the future, longitudinal research including different gene variants may contribute to a better understanding of the nature of endurance performance.

  17. The association of ACE gene polymorphism with diabetic kidney disease and renoprotective efficacy of valsartan

    Directory of Open Access Journals (Sweden)

    Yuying Wang

    2016-09-01

    Full Text Available Introduction: To investigate the associations between the insertion/deletion (I/D polymorphisms in the angiotensin converting enzyme (ACE gene and susceptibility to diabetic kidney disease (DKD; and the efficacy of valsartan in reducing the urine protein in Type 2 diabetes mellitus (T2DM patients. Materials and methods: We enrolled 128 T2DM patients in this study, including 54 cases with DKD (DKD+ and 74 controls (DKD–. The ACE polymorphism was assayed by polymerase chain reaction (PCR, and the genotype distribution and allele frequency were analyzed. The DKD+ group was subdivided into the DD, ID and II subgroups, based on their genotypes. In addition, patients with DKD received valsartan treatment for 12 weeks. We determined changes in the urinary albumin to creatinine ratio (ACR and serum creatinine (SCr. Results: The frequencies of the genotypes DD and ID were higher in the DKD+ than in the DKD– group. The frequency of allele D was higher, and of allele I was lower, in the DKD+ than in DKD– group (p < 0.05. Following valsartan treatment, albuminuria was significantly decreased in subgroups DD and ID (p < 0.05. Conclusions: In T2DM patients, the ACE I/D polymorphism was associated with onset of DKD. Furthermore, the ACE I/D polymorphism influenced the renoprotective response to valsartan: Patients with the DD genotype benefitted the most from this treatment.

  18. Role of ACE and PAI-1 Polymorphisms in the Development and Progression of Diabetic Retinopathy

    Science.gov (United States)

    Saleem, Saba; Azam, Aisha; Maqsood, Sundus Ijaz; Muslim, Irfan; Bashir, Shaheena; Fazal, Nosheen; Riaz, Moeen; Ali, Syeda Hafiza Benish; Niazi, Muhammad Khizar; Ishaq, Mazhar; Waheed, Nadia Khalida; Qamar, Raheel; Azam, Maleeha

    2015-01-01

    In the present study we determined the association of angiotensin converting enzyme (ACE) and plasminogen activator inhibitor-1 (PAI-1) gene polymorphisms with diabetic retinopathy (DR) and its sub-clinical classes in Pakistani type 2 diabetic patients. A total of 353 diabetic subjects including 160 DR and 193 diabetic non retinopathy (DNR) as well as 198 healthy controls were genotyped by allele specific polymerase chain reaction (PCR) for ACE Insertion/Deletion (ID) polymorphism, rs4646994 in intron 16 and PAI-1 4G/5G (deletion/insertion) polymorphism, rs1799768 in promoter region of the gene. To statistically assess the genotype-phenotype association, multivariate logistic regression analysis was applied to the genotype data of DR, DNR and control individuals as well as the subtypes of DR. The ACE genotype ID was found to be significantly associated with DR (p = 0.009, odds ratio (OR) 1.870 [95% confidence interval (CI) = 1.04–3.36]) and its sub-clinical class non-proliferative DR (NPDR) (p = 0.006, OR 2.250 [95% CI = 1.098–4.620]), while PAI polymorphism did not show any association with DR in the current cohort. In conclusion in Pakistani population the ACE ID polymorphism was observed to be significantly associated with DR and NPDR, but not with the severe form of the disease i.e. proliferative DR (PDR). PMID:26658948

  19. Role of ACE and PAI-1 Polymorphisms in the Development and Progression of Diabetic Retinopathy.

    Directory of Open Access Journals (Sweden)

    Saba Saleem

    Full Text Available In the present study we determined the association of angiotensin converting enzyme (ACE and plasminogen activator inhibitor-1 (PAI-1 gene polymorphisms with diabetic retinopathy (DR and its sub-clinical classes in Pakistani type 2 diabetic patients. A total of 353 diabetic subjects including 160 DR and 193 diabetic non retinopathy (DNR as well as 198 healthy controls were genotyped by allele specific polymerase chain reaction (PCR for ACE Insertion/Deletion (ID polymorphism, rs4646994 in intron 16 and PAI-1 4G/5G (deletion/insertion polymorphism, rs1799768 in promoter region of the gene. To statistically assess the genotype-phenotype association, multivariate logistic regression analysis was applied to the genotype data of DR, DNR and control individuals as well as the subtypes of DR. The ACE genotype ID was found to be significantly associated with DR (p = 0.009, odds ratio (OR 1.870 [95% confidence interval (CI = 1.04-3.36] and its sub-clinical class non-proliferative DR (NPDR (p = 0.006, OR 2.250 [95% CI = 1.098-4.620], while PAI polymorphism did not show any association with DR in the current cohort. In conclusion in Pakistani population the ACE ID polymorphism was observed to be significantly associated with DR and NPDR, but not with the severe form of the disease i.e. proliferative DR (PDR.

  20. Implementation of Cascade Gamma and Positron Range Corrections for I-124 Small Animal PET

    Science.gov (United States)

    Harzmann, S.; Braun, F.; Zakhnini, A.; Weber, W. A.; Pietrzyk, U.; Mix, M.

    2014-02-01

    Small animal Positron Emission Tomography (PET) should provide accurate quantification of regional radiotracer concentrations and high spatial resolution. This is challenging for non-pure positron emitters with high positron endpoint energies, such as I-124: On the one hand the cascade gammas emitted from this isotope can produce coincidence events with the 511 keV annihilation photons leading to quantification errors. On the other hand the long range of the high energy positron degrades spatial resolution. This paper presents the implementation of a comprehensive correction technique for both of these effects. The established corrections include a modified sinogram-based tail-fitting approach to correct for scatter, random and cascade gamma coincidences and a compensation for resolution degradation effects during the image reconstruction. Resolution losses were compensated for by an iterative algorithm which incorporates a convolution kernel derived from line source measurements for the microPET Focus 120 system. The entire processing chain for these corrections was implemented, whereas previous work has only addressed parts of this process. Monte Carlo simulations with GATE and measurements of mice with the microPET Focus 120 show that the proposed method reduces absolute quantification errors on average to 2.6% compared to 15.6% for the ordinary Maximum Likelihood Expectation Maximization algorithm. Furthermore resolution was improved in the order of 11-29% depending on the number of convolution iterations. In summary, a comprehensive, fast and robust algorithm for the correction of small animal PET studies with I-124 was developed which improves quantitative accuracy and spatial resolution.

  1. Integrated PET/MR breast cancer imaging: Attenuation correction and implementation of a 16-channel RF coil

    Energy Technology Data Exchange (ETDEWEB)

    Oehmigen, Mark, E-mail: mark.oehmigen@uni-due.de; Lindemann, Maike E. [High Field and Hybrid MR Imaging, University Hospital Essen, Essen 45147 (Germany); Lanz, Titus [Rapid Biomedical GmbH, Rimpar 97222 (Germany); Kinner, Sonja [Institute for Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen 45147 (Germany); Quick, Harald H. [High Field and Hybrid MR Imaging, University Hospital Essen, Essen 45147, Germany and Erwin L. Hahn Institute for MR Imaging, University Duisburg-Essen, Essen 45141 (Germany)

    2016-08-15

    Purpose: This study aims to develop, implement, and evaluate a 16-channel radiofrequency (RF) coil for integrated positron emission tomography/magnetic resonance (PET/MR) imaging of breast cancer. The RF coil is designed for optimized MR imaging performance and PET transparency and attenuation correction (AC) is applied for accurate PET quantification. Methods: A 16-channel breast array RF coil was designed for integrated PET/MR hybrid imaging of breast cancer lesions. The RF coil features a lightweight rigid design and is positioned with a spacer at a defined position on the patient table of an integrated PET/MR system. Attenuation correction is performed by generating and applying a dedicated 3D CT-based template attenuation map. Reposition accuracy of the RF coil on the system patient table while using the positioning frame was tested in repeated measurements using MR-visible markers. The MR, PET, and PET/MR imaging performances were systematically evaluated using modular breast phantoms. Attenuation correction of the RF coil was evaluated with difference measurements of the active breast phantoms filled with radiotracer in the PET detector with and without the RF coil in place, serving as a standard of reference measurement. The overall PET/MR imaging performance and PET quantification accuracy of the new 16-channel RF coil and its AC were then evaluated in first clinical examinations on ten patients with local breast cancer. Results: The RF breast array coil provides excellent signal-to-noise ratio and signal homogeneity across the volume of the breast phantoms in MR imaging and visualizes small structures in the phantoms down to 0.4 mm in plane. Difference measurements with PET revealed a global loss and thus attenuation of counts by 13% (mean value across the whole phantom volume) when the RF coil is placed in the PET detector. Local attenuation ranging from 0% in the middle of the phantoms up to 24% was detected in the peripheral regions of the phantoms at

  2. Detector normalization and scatter correction for the jPET-D4: A 4-layer depth-of-interaction PET scanner

    Energy Technology Data Exchange (ETDEWEB)

    Kitamura, Keishi [Shimadzu Corporation, 1 Nishinokyo-Kuwabaracho, Nakagyo-ku, Kyoto-shi, Kyoto 604-8511 (Japan)]. E-mail: kitam@shimadzu.co.jp; Ishikawa, Akihiro [Shimadzu Corporation, 1 Nishinokyo-Kuwabaracho, Nakagyo-ku, Kyoto-shi, Kyoto 604-8511 (Japan); Mizuta, Tetsuro [Shimadzu Corporation, 1 Nishinokyo-Kuwabaracho, Nakagyo-ku, Kyoto-shi, Kyoto 604-8511 (Japan); Yamaya, Taiga [National Institute of Radiological Sciences, 9-1 Anagawa-4, Inage-ku, Chiba-shi, Chiba 263-8555 (Japan); Yoshida, Eiji [National Institute of Radiological Sciences, 9-1 Anagawa-4, Inage-ku, Chiba-shi, Chiba 263-8555 (Japan); Murayama, Hideo [National Institute of Radiological Sciences, 9-1 Anagawa-4, Inage-ku, Chiba-shi, Chiba 263-8555 (Japan)

    2007-02-01

    The jPET-D4 is a brain positron emission tomography (PET) scanner composed of 4-layer depth-of-interaction (DOI) detectors with a large number of GSO crystals, which achieves both high spatial resolution and high scanner sensitivity. Since the sensitivity of each crystal element is highly dependent on DOI layer depth and incidental {gamma} ray energy, it is difficult to estimate normalization factors and scatter components with high statistical accuracy. In this work, we implemented a hybrid scatter correction method combined with component-based normalization, which estimates scatter components with a dual energy acquisition using a convolution subtraction-method for an estimation of trues from an upper energy window. In order to reduce statistical noise in sinograms, the implemented scheme uses the DOI compression (DOIC) method, that combines deep pairs of DOI layers into the nearest shallow pairs of DOI layers with natural detector samplings. Since the compressed data preserve the block detector configuration, as if the data are acquired using 'virtual' detectors with high {gamma}-ray stopping power, these correction methods can be applied directly to DOIC sinograms. The proposed method provides high-quality corrected images with low statistical noise, even for a multi-layer DOI-PET.

  3. Single nucleotide polymorphisms of the angiotensin-converting enzyme (ACE gene are associated with essential hypertension and increased ACE enzyme levels in Mexican individuals.

    Directory of Open Access Journals (Sweden)

    Nancy Martínez-Rodríguez

    Full Text Available AIM: To explore the role of the ACE gene polymorphisms in the risk of essential hypertension in Mexican Mestizo individuals and evaluate the correlation between these polymorphisms and the serum ACE levels. METHODS: Nine ACE gene polymorphisms were genotyped by 5' exonuclease TaqMan genotyping assays and polymerase chain reaction (PCR in 239 hypertensive and 371 non- hypertensive Mexican individuals. Haplotypes were constructed after linkage disequilibrium analysis. ACE serum levels were determined in selected individuals according to different haplotypes. RESULTS: Under a dominant model, rs4291 rs4335, rs4344, rs4353, rs4362, and rs4363 polymorphisms were associated with an increased risk of hypertension after adjusting for age, gender, BMI, triglycerides, alcohol consumption, and smoking. Five polymorphisms (rs4335, rs4344, rs4353, rs4362 and rs4363 were in strong linkage disequilibrium and were included in four haplotypes: H1 (AAGCA, H2 (GGATG, H3 (AGATG, and H4 (AGACA. Haplotype H1 was associated with decreased risk of hypertension, while haplotype H2 was associated with an increased risk of hypertension (OR = 0.77, P = 0.023 and OR = 1.41, P = 0.004 respectively. According to the codominant model, the H2/H2 and H1/H2 haplotype combinations were significantly associated with risk of hypertension after adjusted by age, gender, BMI, triglycerides, alcohol consumption, and smoking (OR = 2.0; P = 0.002 and OR = 2.09; P = 0.011, respectively. Significant elevations in serum ACE concentrations were found in individuals with the H2 haplotype (H2/H2 and H2/H1 as compared to H1/H1 individuals (P = 0.0048. CONCLUSION: The results suggest that single nucleotide polymorphisms and the "GGATG" haplotype of the ACE gene are associated with the development of hypertension and with increased ACE enzyme levels.

  4. MR-guided PET motion correction in LOR space using generic projection data for image reconstruction with PRESTO

    International Nuclear Information System (INIS)

    Scheins, J.; Ullisch, M.; Tellmann, L.; Weirich, C.; Rota Kops, E.; Herzog, H.; Shah, N.J.

    2013-01-01

    The BrainPET scanner from Siemens, designed as hybrid MR/PET system for simultaneous acquisition of both modalities, provides high-resolution PET images with an optimum resolution of 3 mm. However, significant head motion often compromises the achievable image quality, e.g. in neuroreceptor studies of human brain. This limitation can be omitted when tracking the head motion and accurately correcting measured Lines-of-Response (LORs). For this purpose, we present a novel method, which advantageously combines MR-guided motion tracking with the capabilities of the reconstruction software PRESTO (PET Reconstruction Software Toolkit) to convert motion-corrected LORs into highly accurate generic projection data. In this way, the high-resolution PET images achievable with PRESTO can also be obtained in presence of severe head motion

  5. Compton scatter and randoms corrections for origin ensembles 3D PET reconstructions

    Energy Technology Data Exchange (ETDEWEB)

    Sitek, Arkadiusz [Harvard Medical School, Boston, MA (United States). Dept. of Radiology; Brigham and Women' s Hospital, Boston, MA (United States); Kadrmas, Dan J. [Utah Univ., Salt Lake City, UT (United States). Utah Center for Advanced Imaging Research (UCAIR)

    2011-07-01

    In this work we develop a novel approach to correction for scatter and randoms in reconstruction of data acquired by 3D positron emission tomography (PET) applicable to tomographic reconstruction done by the origin ensemble (OE) approach. The statistical image reconstruction using OE is based on calculation of expectations of the numbers of emitted events per voxel based on complete-data space. Since the OE estimation is fundamentally different than regular statistical estimators such those based on the maximum likelihoods, the standard methods of implementation of scatter and randoms corrections cannot be used. Based on prompts, scatter, and random rates, each detected event is graded in terms of a probability of being a true event. These grades are utilized by the Markov Chain Monte Carlo (MCMC) algorithm used in OE approach for calculation of the expectation over the complete-data space of the number of emitted events per voxel (OE estimator). We show that the results obtained with the OE are almost identical to results obtained by the maximum likelihood-expectation maximization (ML-EM) algorithm for reconstruction for experimental phantom data acquired using Siemens Biograph mCT 3D PET/CT scanner. The developed correction removes artifacts due to scatter and randoms in investigated 3D PET datasets. (orig.)

  6. CT vs 68Ge attenuation correction in a combined PET/CT system: evaluation of the effect of lowering the CT tube current

    International Nuclear Information System (INIS)

    Kamel, Ehab; Hany, Thomas F.; Burger, Cyrill; Treyer, Valerie; Schulthess von, Gustav K.; Buck, Alfred; Lonn, Albert H.R.

    2002-01-01

    With the introduction of combined positron emission tomography/computed tomography (PET/CT) systems, several questions have to be answered. In this work we addressed two of these questions: (a) to what value can the CT tube current be reduced while still yielding adequate maps for the attenuation correction of PET emission scans and (b) how do quantified uptake values in tumours derived from CT and germanium-68 attenuation correction compare. In 26 tumour patients, multidetector CT scans were acquired with 10, 40, 80 and 120 mA (CT 10 , CT 40 , CT 80 and CT 120 ) and used for the attenuation correction of a single FDG PET emission scan, yielding four PET scans designated PET CT10 -PET CT120 . In 60 tumorous lesions, FDG uptake and lesion size were quantified on PET CT10 -PET CT120 . In another group of 18 patients, one CT scan acquired with 80 mA and a standard transmission scan acquired using 68 Ge sources were employed for the attenuation correction of the FDG emission scan (PET CT80 , PET 68Ge ). Uptake values and lesion size in 26 lesions were compared on PET CT80 and PET 68Ge . In the first group of patients, analysis of variance revealed no significant effect of CT current on tumour FDG uptake or lesion size. In the second group, tumour FDG uptake was slightly higher using CT compared with 68 Ge attenuation correction, especially in lesions with high FDG uptake. Lesion size was similar on PET CT80 and PET 68Ge . In conclusion, low CT currents yield adequate maps for the attenuation correction of PET emission scans. Although the discrepancy between CT- and 68 Ge-derived uptake values is probably not relevant in most cases, it should be kept in mind if standardised uptake values derived from CT and 68 Ge attenuation correction are compared. (orig.)

  7. Insertion/deletion polymorphism of ACE gene in females with peripartum cardiomyopathy: A case-control study

    Directory of Open Access Journals (Sweden)

    Irfan Yaqoob

    2018-01-01

    Conclusion: ACE DD genotype and overall frequency of D allele is significantly higher in patients with PPCM. Also, the presence of DD genotype is associated with worse systolic performance indices measured echocardiographically.

  8. Does the Angiotensin-converting enzyme (ACE gene insertion/deletion polymorphism modify the response to ACE inhibitor therapy? – A systematic review

    Directory of Open Access Journals (Sweden)

    Perna Annalisa

    2005-10-01

    Full Text Available Abstract Background Pharmacogenetic testing to individualize ACE inhibitor therapy remains controversial. We conducted a systematic review to assess the effect modification of the insertion/deletion (I/D polymorphism of the ACE gene on any outcome in patients treated with ACE inhibitors for cardiovascular and/or renal disease. Methods Our systematic review involved searching six electronic databases, then contacting the investigators (and pharmaceutical industry representatives responsible for the creation of these databases. Two reviewers independently selected relevant randomized, placebo-controlled trials and abstracted from each study details on characteristics and quality. Results Eleven studies met our inclusion criteria. Despite repeated efforts to contact authors, only four of the eleven studies provided sufficient data to quantify the effect modification by genotypes. We observed a trend towards better response to ACE inhibitors in Caucasian DD carriers compared to II carriers, in terms of blood pressure, proteinuria, glomerular filtration rate, ACE activity and progression to end-stage renal failure. Pooling of the results was inappropriate, due to heterogeneity in ethnicity, clinical domains and outcomes. Conclusion Lack of sufficient genetic data from the reviewed studies precluded drawing any convincing conclusions. Better reporting of genetic data are needed to confirm our preliminary observations concerning better response to ACE inhibitors among Caucasian DD carriers as compared to II carriers.

  9. Association of insertion/deletion polymorphism of angiotensin-converting enzyme gene among Malay male hypertensive subjects in response to ACE inhibitors.

    Science.gov (United States)

    Heidari, Farzad; Vasudevan, Ramachandran; Mohd Ali, Siti Zubaidah; Ismail, Patimah; Etemad, Ali; Pishva, Seyyed Reza; Othman, Fauziah; Abu Bakar, Suhaili

    2015-12-01

    Several studies show that the insertion/deletion (I/D) polymorphism of the angiotensin-converting enzyme (ACE) gene has been associated with hypertension in various populations. The present study sought to determine the association of the I/D gene polymorphism among Malay male essential hypertensive subjects in response to ACE inhibitors (enalapril and lisinopril). A total of 72 patients with newly diagnosed hypertension and 72 healthy subjects were recruited in this study. Blood pressure was recorded from 0 to 24 weeks of treatment with enalapril or lisinopril. Genotyping of the I/D polymorphism was carried out using a standard PCR method. Statistically significant association of the D allele of the ACE gene was observed between the case and control subjects (p ACE gene. Patients carrying the DD genotype had higher blood pressure-lowering response when treated with ACE inhibitors enalapril or lisinopril than those carrying ID and II genotypes, suggesting that the D allele may be a possible genetic marker for essential hypertension among Malay male subjects. © The Author(s) 2014.

  10. The design and implementation of a motion correction scheme for neurological PET

    International Nuclear Information System (INIS)

    Bloomfield, Peter M; Spinks, Terry J; Reed, Johnny; Schnorr, Leonard; Westrip, Anthony M; Livieratos, Lefteris; Fulton, Roger; Jones, Terry

    2003-01-01

    A method is described to monitor the motion of the head during neurological positron emission tomography (PET) acquisitions and to correct the data post acquisition for the recorded motion prior to image reconstruction. The technique uses an optical tracking system, Polaris TM , to accurately monitor the position of the head during the PET acquisition. The PET data are acquired in list mode where the events are written directly to disk during acquisition. The motion tracking information is aligned to the PET data using a sequence of pseudo-random numbers, which are inserted into the time tags in the list mode event stream through the gating input interface on the tomograph. The position of the head is monitored during the transmission acquisition, and it is assumed that there is minimal head motion during this measurement. Each event, prompt and delayed, in the list mode event stream is corrected for motion and transformed into the transmission space. For a given line of response, normalization, including corrections for detector efficiency, geometry and crystal interference and dead time are applied prior to motion correction and rebinning in the sinogram. A series of phantom experiments were performed to confirm the accuracy of the method: (a) a point source located in three discrete axial positions in the tomograph field of view, 0 mm, 10 mm and 20 mm from a reference point, (b) a multi-line source phantom rotated in both discrete and gradual rotations through ±5 deg. and ±15 deg, including a vertical and horizontal movement in the plane. For both phantom experiments images were reconstructed for both the fixed and motion corrected data. Measurements for resolution, full width at half maximum (FWHM) and full width at tenth maximum (FWTM), were calculated from these images and a comparison made between the fixed and motion corrected datasets. From the point source measurements, the FWHM at each axial position was 7.1 mm in the horizontal direction, and

  11. The importance of association between angiotensin-converting enzyme (ACE) Gene I/D polymorphism and diabetic peripheral neuropathy.

    Science.gov (United States)

    Inanir, Ahmet; Basol, Nursah; Karakus, Nevin; Yigit, Serbulent

    2013-11-10

    Diabetic peripheral neuropathy (DPN) is a microvascular complication of diabetes mellitus (DM) due to decreasing quality of life. In the present study, it is aimed to evaluate angiotensin-converting enzyme (ACE) Gene I/D polymorphism in Turkish population. Two hundred and thirty-five DPN patients and two hundred and eighty-one controls were enrolled in this study. Genomic DNA was isolated and genotyped using polymerase chain reaction (PCR) analyses for the ACE gene I/D polymorphism. Baseline characteristics of the DPN patients according to ACE genotypes were similar, except for history of hypertension. The frequency of II genotype was significantly higher in patients with positive history of hypertension than the patients with negative history of hypertension (p=0.013). DD genotype of I/D polymorphism was found to be a susceptibility factor for DPN in homozygous form (p=0.032). According to allele frequencies, D allele of I/D polymorphism was found to be a susceptibility factor for DPN (p=0.031). ACE gene I/D polymorphism may research in DM patients to determine genetic predisposition for DPN. It can be useful for taking early measures and avoiding DPN in a Turkish population. © 2013 Elsevier B.V. All rights reserved.

  12. Characterization of the relationship between APOBEC3B deletion and ACE Alu insertion.

    Directory of Open Access Journals (Sweden)

    Kang Wang

    Full Text Available The insertion/deletion (I/D polymorphism of the angiotensin converting enzyme (ACE, commonly associated with many diseases, is believed to have affected human adaptation to environmental changes during the out-of-Africa expansion. APOBEC3B (A3B, a member of the cytidine deaminase family APOBEC3s, also exhibits a variable gene insertion/deletion polymorphism across world populations. Using data available from published reports, we examined the global geographic distribution of ACE and A3B genotypes. In tracking the modern human dispersal routes of these two genes, we found that the variation trends of the two I/D polymorphisms were directly correlated. We observed that the frequencies of ACE insertion and A3B deletion rose in parallel along the expansion route. To investigate the presence of a correlation between the two polymorphisms and the effect of their interaction on human health, we analyzed 1199 unrelated Chinese adults to determine their genotypes and other important clinical characteristics. We discovered a significant difference between the ACE genotype/allele distribution in the A3B DD and A3B II/ID groups (P = 0.045 and 0.015, respectively, indicating that the ACE Alu I allele frequency in the former group was higher than in the latter group. No specific clinical phenotype could be associated with the interaction between the ACE and A3B I/D polymorphisms. A3B has been identified as a powerful inhibitor of Alu retrotransposition, and primate A3 genes have undergone strong positive selection (and expansion for restricting the mobility of endogenous retrotransposons during evolution. Based on these findings, we suggest that the ACE Alu insertion was enabled (facilitated by the A3B deletion and that functional loss of A3B provided an opportunity for enhanced human adaptability and survival in response to the environmental and climate challenges arising during the migration from Africa.

  13. A case control association study of ACE gene polymorphism (I/D) with hypertension in Punjabi population from Faisalabad, Pakistan.

    Science.gov (United States)

    Hussain, Misbah; Awan, Fazli Rabbi; Gujjar, Amna; Hafeez, Shakir; Islam, Mehboob

    2018-01-01

    Angiotensin converting enzyme (ACE) is a key component of renin angiotensin aldosterone system. It converts angiotensin I to angiotensin II. Insertion/deletion (I/D) polymorphism of ACE gene is found associated with several complications. However, its association with hypertension and related metabolic diseases is still controversial. So, the aim of the present study was to check this association for Punjabi population from Faisalabad, Pakistan. For this purpose, blood samples (patients = 100, controls = 48) were collected and several biochemical parameters were measured. Genotyping for ACE (I/D) polymorphism was performed by polymerase chain reaction (PCR) assay. ID genotype is found prevalent in the studied population as 41% in control subjects and 61% in patients. Furthermore, chi-square analysis showed significant (p = 0.005) difference for genotypic frequencies between both groups. One-way ANOVA for association of II, ID, and DD genotypes with anthropometric, clinical, and biochemical parameters showed that in patient group, DD genotype is significantly (p = 0.041) associated with systolic blood pressure (SBP). Moreover, ID genotype is found associated with the presence of cardiovascular diseases. This study concludes that DD genotype is strongly associated with higher SBP in hypertensive patients.

  14. Attenuation correction for the HRRT PET-scanner using transmission scatter correction and total variation regularization

    DEFF Research Database (Denmark)

    Keller, Sune H; Svarer, Claus; Sibomana, Merence

    2013-01-01

    scatter correction in the μ-map reconstruction and total variation filtering to the transmission processing. Results: Comparing MAP-TR and the new TXTV with gold standard CT-based attenuation correction, we found that TXTV has less bias as compared to MAP-TR. We also compared images acquired at the HRRT......In the standard software for the Siemens high-resolution research tomograph (HRRT) positron emission tomography (PET) scanner the most commonly used segmentation in the μ -map reconstruction for human brain scans is maximum a posteriori for transmission (MAP-TR). Bias in the lower cerebellum...

  15. PET/MR imaging of bone lesions - implications for PET quantification from imperfect attenuation correction

    International Nuclear Information System (INIS)

    Samarin, Andrei; Burger, Cyrill; Crook, David W.; Burger, Irene A.; Schmid, Daniel T.; Schulthess, Gustav K. von; Kuhn, Felix P.; Wollenweber, Scott D.

    2012-01-01

    Accurate attenuation correction (AC) is essential for quantitative analysis of PET tracer distribution. In MR, the lack of cortical bone signal makes bone segmentation difficult and may require implementation of special sequences. The purpose of this study was to evaluate the need for accurate bone segmentation in MR-based AC for whole-body PET/MR imaging. In 22 patients undergoing sequential PET/CT and 3-T MR imaging, modified CT AC maps were produced by replacing pixels with values of >100 HU, representing mostly bone structures, by pixels with a constant value of 36 HU corresponding to soft tissue, thereby simulating current MR-derived AC maps. A total of 141 FDG-positive osseous lesions and 50 soft-tissue lesions adjacent to bones were evaluated. The mean standardized uptake value (SUVmean) was measured in each lesion in PET images reconstructed once using the standard AC maps and once using the modified AC maps. Subsequently, the errors in lesion tracer uptake for the modified PET images were calculated using the standard PET image as a reference. Substitution of bone by soft tissue values in AC maps resulted in an underestimation of tracer uptake in osseous and soft tissue lesions adjacent to bones of 11.2 ± 5.4 % (range 1.5-30.8 %) and 3.2 ± 1.7 % (range 0.2-4 %), respectively. Analysis of the spine and pelvic osseous lesions revealed a substantial dependence of the error on lesion composition. For predominantly sclerotic spine lesions, the mean underestimation was 15.9 ± 3.4 % (range 9.9-23.5 %) and for osteolytic spine lesions, 7.2 ± 1.7 % (range 4.9-9.3 %), respectively. CT data simulating treating bone as soft tissue as is currently done in MR maps for PET AC leads to a substantial underestimation of tracer uptake in bone lesions and depends on lesion composition, the largest error being seen in sclerotic lesions. Therefore, depiction of cortical bone and other calcified areas in MR AC maps is necessary for accurate quantification of tracer uptake

  16. Association of Angiotensin-Converting Enzyme (ACE) Gene Polymorphism with Inflammation and Cellular Cytotoxicity in Vitiligo Patients.

    Science.gov (United States)

    Rashed, Laila; Abdel Hay, Rania; Mahmoud, Rania; Hasan, Nermeen; Zahra, Amr; Fayez, Salwa

    2015-01-01

    Vitiligo is a disorder with profound heterogeneity in its aetio-pathophysiology. Angiotensin converting enzyme (ACE) plays an important role in the physiology of the vasculature, blood pressure and inflammation. An insertion/deletion (I/D) polymorphism of the ACE gene was reported be associated with the development of vitiligo. Our aim was to evaluate the ACE I/D polymorphism in vitiligo patients and controls. Our second aim was to find a possible association between ACE gene polymorphism and inflammatory mediators (as interleukin (IL)-6) and/or cellular cytotoxicity induced by serum nitrite (as a breakdown product of the cytotoxic nitric oxide) in vitiligo patients. This case-control study included 74 vitiligo patients and 75 apparently healthy controls. The distribution of ACE gene I/D genotype was investigated using PCR. Serum ACE, IL-6 and nitrite were measured by colorimetric method, ELISA and Griess assay respectively. The ACE allele frequency was significantly different between vitiligo patients and healthy controls (P = 0.026). However there was no significant difference between the ACE genotyping frequency in both groups (P = 0.115). There were statistically significant higher VIDA score (P = 0.007), and serum IL-6 (P ACE, IL-6 and nitrite in vitiligo patients were statistically significantly higher than those in controls. As a conclusion, ACE gene polymorphism might grant susceptibility to develop vitiligo. Serum IL-6 and nitrite levels might have an important role in the pathogenesis of vitiligo. Targeting these two factors might have an implication in the treatment of some resistant cases.

  17. The utility of 18F-FDG PET/CT for diagnosis and adjustment of therapy in patients with active chronic sarcoidosis.

    Science.gov (United States)

    Sobic-Saranovic, Dragana; Grozdic, Isidora; Videnovic-Ivanov, Jelica; Vucinic-Mihailovic, Violeta; Artiko, Vera; Saranovic, Djordjije; Djuric-Stefanovic, Aleksandra; Masulovic, Dragan; Odalovic, Strahinja; Ilic-Dudvarski, Aleksandra; Popevic, Spasoje; Pavlovic, Smiljana; Obradovic, Vladimir

    2012-10-01

    The purpose of this study was to assess the utility of (18)F-FDG PET/CT for detection of inflammation in granulomatous sites and management of patients with chronic sarcoidosis. The 3 specific aims were to assess differences between (18)F-FDG PET/CT and multidetector CT (MDCT) findings, to compare (18)F-FDG PET/CT results with serum levels of angiotensin-converting enzyme (ACE), and to determine whether (18)F-FDG PET/CT findings are associated with the decision to change therapy. We studied 90 sarcoidosis patients (mean age ± SD, 47 ± 12 y; 32 men and 58 women) with persistent symptoms who were referred for (18)F-FDG PET/CT evaluation to assess the extent of inflammation. They also underwent MDCT and measurement of serum ACE level. After the follow-up (12 ± 5 mo after (18)F-FDG PET/CT), the clinical status and changes in therapy were analyzed. (18)F-FDG PET/CT detected inflammation in 74 patients (82%) (maximum standardized uptake value, 8.1 ± 3.9). MDCT was positive for sarcoidosis in 6 additional patients (80, 89%). The difference between the 2 methods was not significant (P = 0.238, McNemar test), and their agreement was fair (κ = 0.198). Although ACE levels were significantly higher in patients with positive than negative (18)F-FDG PET/CT results (P = 0.002, Mann-Whitney test), 38 patients (51%) with positive (18)F-FDG PET/CT results had normal ACE levels. The therapy was initiated or changed in 73 out of 90 patients (81%). Both univariate and multivariate logistic regression analyses indicated that positive (18)F-FDG PET/CT results were significantly (P changes in therapy, with no contribution from age, sex, ACE level, CT results, or previous therapy. Our results indicate that (18)F-FDG PET/CT is a useful adjunct to other diagnostic methods for detecting active inflammatory sites in chronic sarcoidosis patients with persistent symptoms, especially those with normal ACE levels. (18)F-FDG PET/CT proved advantageous for determining the spread of active

  18. Ultra-low Dose CT for Attenuation Correction of 82Rb Cardiac PET

    DEFF Research Database (Denmark)

    Sørensen, Maria Balshøj; Bouchelouche, Kirsten; Tolbod, Lars Poulsen

    Aim: Myocardial perfusion imaging (MPI) using cardiac PET with tracers like 82Rb and 15O-water is substantially lower in radiation dose than classic MIBI-based SPECT. However, for cardiac PET, the dose contribution of CT for attenuation correction (CTAC) is typically 20-30% of the total dose....... To reduce the total radiation dose of cardiac PET further, we set out to examine if the use of ultra-low dose CTAC (UL-CTAC) would affect the accuracy of the quantitative parameters related to MPI. Furthermore, we examined whether the low quality of the UL-CTAC would affect the technologist’s ability...... to perform manual adjustment for misalignment between PET and CTAC. The CT reconstruction algorithm Q.AC was used to improve quality and consistency of the CTAC. Method: 23 consecutive clinical patients (BMI: 26.9 [range: 15.4-38.8]) referred for 82Rb PET rest and stress imaging were included in the study...

  19. Attenuation correction for the large non-human primate brain imaging using microPET

    International Nuclear Information System (INIS)

    Naidoo-Variawa, S; Lehnert, W; Kassiou, M; Banati, R; Meikle, S R

    2010-01-01

    Assessment of the biodistribution and pharmacokinetics of radiopharmaceuticals in vivo is often performed on animal models of human disease prior to their use in humans. The baboon brain is physiologically and neuro-anatomically similar to the human brain and is therefore a suitable model for evaluating novel CNS radioligands. We previously demonstrated the feasibility of performing baboon brain imaging on a dedicated small animal PET scanner provided that the data are accurately corrected for degrading physical effects such as photon attenuation in the body. In this study, we investigated factors affecting the accuracy and reliability of alternative attenuation correction strategies when imaging the brain of a large non-human primate (papio hamadryas) using the microPET Focus 220 animal scanner. For measured attenuation correction, the best bias versus noise performance was achieved using a 57 Co transmission point source with a 4% energy window. The optimal energy window for a 68 Ge transmission source operating in singles acquisition mode was 20%, independent of the source strength, providing bias-noise performance almost as good as for 57 Co. For both transmission sources, doubling the acquisition time had minimal impact on the bias-noise trade-off for corrected emission images, despite observable improvements in reconstructed attenuation values. In a [ 18 F]FDG brain scan of a female baboon, both measured attenuation correction strategies achieved good results and similar SNR, while segmented attenuation correction (based on uncorrected emission images) resulted in appreciable regional bias in deep grey matter structures and the skull. We conclude that measured attenuation correction using a single pass 57 Co (4% energy window) or 68 Ge (20% window) transmission scan achieves an excellent trade-off between bias and propagation of noise when imaging the large non-human primate brain with a microPET scanner.

  20. Direct Reconstruction of CT-based Attenuation Correction Images for PET with Cluster-Based Penalties

    Science.gov (United States)

    Kim, Soo Mee; Alessio, Adam M.; De Man, Bruno; Asma, Evren; Kinahan, Paul E.

    2015-01-01

    Extremely low-dose CT acquisitions for the purpose of PET attenuation correction will have a high level of noise and biasing artifacts due to factors such as photon starvation. This work explores a priori knowledge appropriate for CT iterative image reconstruction for PET attenuation correction. We investigate the maximum a posteriori (MAP) framework with cluster-based, multinomial priors for the direct reconstruction of the PET attenuation map. The objective function for direct iterative attenuation map reconstruction was modeled as a Poisson log-likelihood with prior terms consisting of quadratic (Q) and mixture (M) distributions. The attenuation map is assumed to have values in 4 clusters: air+background, lung, soft tissue, and bone. Under this assumption, the MP was a mixture probability density function consisting of one exponential and three Gaussian distributions. The relative proportion of each cluster was jointly estimated during each voxel update of direct iterative coordinate decent (dICD) method. Noise-free data were generated from NCAT phantom and Poisson noise was added. Reconstruction with FBP (ramp filter) was performed on the noise-free (ground truth) and noisy data. For the noisy data, dICD reconstruction was performed with the combination of different prior strength parameters (β and γ) of Q- and M-penalties. The combined quadratic and mixture penalties reduces the RMSE by 18.7% compared to post-smoothed iterative reconstruction and only 0.7% compared to quadratic alone. For direct PET attenuation map reconstruction from ultra-low dose CT acquisitions, the combination of quadratic and mixture priors offers regularization of both variance and bias and is a potential method to derive attenuation maps with negligible patient dose. However, the small improvement in quantitative accuracy relative to the substantial increase in algorithm complexity does not currently justify the use of mixture-based PET attenuation priors for reconstruction of CT

  1. Motion-corrected whole-heart PET-MR for the simultaneous visualisation of coronary artery integrity and myocardial viability: an initial clinical validation.

    Science.gov (United States)

    Munoz, Camila; Kunze, Karl P; Neji, Radhouene; Vitadello, Teresa; Rischpler, Christoph; Botnar, René M; Nekolla, Stephan G; Prieto, Claudia

    2018-05-12

    Cardiac PET-MR has shown potential for the comprehensive assessment of coronary heart disease. However, image degradation due to physiological motion remains a challenge that could hinder the adoption of this technology in clinical practice. The purpose of this study was to validate a recently proposed respiratory motion-corrected PET-MR framework for the simultaneous visualisation of myocardial viability ( 18 F-FDG PET) and coronary artery anatomy (coronary MR angiography, CMRA) in patients with chronic total occlusion (CTO). A cohort of 14 patients was scanned with the proposed PET-CMRA framework. PET and CMRA images were reconstructed with and without the proposed motion correction approach for comparison purposes. Metrics of image quality including visible vessel length and sharpness were obtained for CMRA for both the right and left anterior descending coronary arteries (RCA, LAD), and relative increase in 18 F-FDG PET signal after motion correction for standard 17-segment polar maps was computed. Resulting coronary anatomy by CMRA and myocardial integrity by PET were visually compared against X-ray angiography and conventional Late Gadolinium Enhancement (LGE) MRI, respectively. Motion correction increased CMRA visible vessel length by 49.9% and 32.6% (RCA, LAD) and vessel sharpness by 12.3% and 18.9% (RCA, LAD) on average compared to uncorrected images. Coronary lumen delineation on motion-corrected CMRA images was in good agreement with X-ray angiography findings. For PET, motion correction resulted in an average 8% increase in 18 F-FDG signal in the inferior and inferolateral segments of the myocardial wall. An improved delineation of myocardial viability defects and reduced noise in the 18 F-FDG PET images was observed, improving correspondence to subendocardial LGE-MRI findings compared to uncorrected images. The feasibility of the PET-CMRA framework for simultaneous cardiac PET-MR imaging in a short and predictable scan time (~11 min) has been

  2. Ultra-low dose CT attenuation correction for PET/CT: analysis of sparse view data acquisition and reconstruction algorithms

    Science.gov (United States)

    Rui, Xue; Cheng, Lishui; Long, Yong; Fu, Lin; Alessio, Adam M.; Asma, Evren; Kinahan, Paul E.; De Man, Bruno

    2015-01-01

    For PET/CT systems, PET image reconstruction requires corresponding CT images for anatomical localization and attenuation correction. In the case of PET respiratory gating, multiple gated CT scans can offer phase-matched attenuation and motion correction, at the expense of increased radiation dose. We aim to minimize the dose of the CT scan, while preserving adequate image quality for the purpose of PET attenuation correction by introducing sparse view CT data acquisition. Methods We investigated sparse view CT acquisition protocols resulting in ultra-low dose CT scans designed for PET attenuation correction. We analyzed the tradeoffs between the number of views and the integrated tube current per view for a given dose using CT and PET simulations of a 3D NCAT phantom with lesions inserted into liver and lung. We simulated seven CT acquisition protocols with {984, 328, 123, 41, 24, 12, 8} views per rotation at a gantry speed of 0.35 seconds. One standard dose and four ultra-low dose levels, namely, 0.35 mAs, 0.175 mAs, 0.0875 mAs, and 0.04375 mAs, were investigated. Both the analytical FDK algorithm and the Model Based Iterative Reconstruction (MBIR) algorithm were used for CT image reconstruction. We also evaluated the impact of sinogram interpolation to estimate the missing projection measurements due to sparse view data acquisition. For MBIR, we used a penalized weighted least squares (PWLS) cost function with an approximate total-variation (TV) regularizing penalty function. We compared a tube pulsing mode and a continuous exposure mode for sparse view data acquisition. Global PET ensemble root-mean-squares-error (RMSE) and local ensemble lesion activity error were used as quantitative evaluation metrics for PET image quality. Results With sparse view sampling, it is possible to greatly reduce the CT scan dose when it is primarily used for PET attenuation correction with little or no measureable effect on the PET image. For the four ultra-low dose levels

  3. Subject-specific bone attenuation correction for brain PET/MR: can ZTE-MRI substitute CT scan accurately?

    Science.gov (United States)

    Khalifé, Maya; Fernandez, Brice; Jaubert, Olivier; Soussan, Michael; Brulon, Vincent; Buvat, Irène; Comtat, Claude

    2017-10-01

    In brain PET/MR applications, accurate attenuation maps are required for accurate PET image quantification. An implemented attenuation correction (AC) method for brain imaging is the single-atlas approach that estimates an AC map from an averaged CT template. As an alternative, we propose to use a zero echo time (ZTE) pulse sequence to segment bone, air and soft tissue. A linear relationship between histogram normalized ZTE intensity and measured CT density in Hounsfield units (HU ) in bone has been established thanks to a CT-MR database of 16 patients. Continuous AC maps were computed based on the segmented ZTE by setting a fixed linear attenuation coefficient (LAC) to air and soft tissue and by using the linear relationship to generate continuous μ values for the bone. Additionally, for the purpose of comparison, four other AC maps were generated: a ZTE derived AC map with a fixed LAC for the bone, an AC map based on the single-atlas approach as provided by the PET/MR manufacturer, a soft-tissue only AC map and, finally, the CT derived attenuation map used as the gold standard (CTAC). All these AC maps were used with different levels of smoothing for PET image reconstruction with and without time-of-flight (TOF). The subject-specific AC map generated by combining ZTE-based segmentation and linear scaling of the normalized ZTE signal into HU was found to be a good substitute for the measured CTAC map in brain PET/MR when used with a Gaussian smoothing kernel of 4~mm corresponding to the PET scanner intrinsic resolution. As expected TOF reduces AC error regardless of the AC method. The continuous ZTE-AC performed better than the other alternative MR derived AC methods, reducing the quantification error between the MRAC corrected PET image and the reference CTAC corrected PET image.

  4. A scheme for PET data normalization in event-based motion correction

    International Nuclear Information System (INIS)

    Zhou, Victor W; Kyme, Andre Z; Fulton, Roger; Meikle, Steven R

    2009-01-01

    Line of response (LOR) rebinning is an event-based motion-correction technique for positron emission tomography (PET) imaging that has been shown to compensate effectively for rigid motion. It involves the spatial transformation of LORs to compensate for motion during the scan, as measured by a motion tracking system. Each motion-corrected event is then recorded in the sinogram bin corresponding to the transformed LOR. It has been shown previously that the corrected event must be normalized using a normalization factor derived from the original LOR, that is, based on the pair of detectors involved in the original coincidence event. In general, due to data compression strategies (mashing), sinogram bins record events detected on multiple LORs. The number of LORs associated with a sinogram bin determines the relative contribution of each LOR. This paper provides a thorough treatment of event-based normalization during motion correction of PET data using LOR rebinning. We demonstrate theoretically and experimentally that normalization of the corrected event during LOR rebinning should account for the number of LORs contributing to the sinogram bin into which the motion-corrected event is binned. Failure to account for this factor may cause artifactual slice-to-slice count variations in the transverse slices and visible horizontal stripe artifacts in the coronal and sagittal slices of the reconstructed images. The theory and implementation of normalization in conjunction with the LOR rebinning technique is described in detail, and experimental verification of the proposed normalization method in phantom studies is presented.

  5. Multiphase contrast-enhanced CT with highly concentrated contrast agent can be used for PET attenuation correction in integrated PET/CT imaging

    International Nuclear Information System (INIS)

    Aschoff, Philip; Plathow, Christian; Lichy, Matthias P.; Claussen, Claus D.; Pfannenberg, Christina; Beyer, Thomas; Erb, Gunter; Oeksuez, Mehmet Oe.

    2012-01-01

    State-of-the-art positron emission tomography/computed tomography (PET/CT) systems incorporate multislice CT technology, thus facilitating the acquisition of multiphase, contrast-enhanced CT data as part of integrated PET/CT imaging protocols. We assess the influence of a highly concentrated iodinated contrast medium (CM) on quantification and image quality following CT-based attenuation correction (CT-AC) in PET/CT. Twenty-eight patients with suspected malignant liver lesions were enrolled prospectively. PET/CT was performed 60 min after injection of 400 MBq of 18 F-fluorodeoxyglucose (FDG) and following the biphasic administration of an intravenous CM (400 mg iodine/ml, Iomeron 400). PET images were reconstructed with CT-AC using any of four acquired CT image sets: non-enhanced, pre-contrast (n-PET), arterial phase (art-PET), portal venous phase (pv-PET) and late phase (late-PET). Normal tissue activity and liver lesions were assessed visually and quantitatively on each PET/CT image set. Visual assessment of PET following CT-AC revealed no noticeable difference in image appearance or quality when using any of the four CT data sets for CT-AC. A total of 44 PET-positive liver lesions was identified in 21 of 28 patients. There were no false-negative or false-positive lesions on PET. Mean standardized uptake values (SUV) in 36 evaluable lesions were: 5.5 (n-PET), 5.8 (art-PET), 5.8 (pv-PET) and 5.8 (late-PET), with the highest mean increase in mean SUV of 6%. Mean SUV changes in liver background increased by up to 10% from n-PET to pv-PET. Multiphase CT data acquired with the use of highly concentrated CM can be used for qualitative assessment of liver lesions in torso FDG PET/CT. The influence on quantification of FDG uptake is small and negligible for most clinical applications. (orig.)

  6. Angiotensin converting enzyme (ACE and ACE2 bind integrins and ACE2 regulates integrin signalling.

    Directory of Open Access Journals (Sweden)

    Nicola E Clarke

    Full Text Available The angiotensin converting enzymes (ACEs are the key catalytic components of the renin-angiotensin system, mediating precise regulation of blood pressure by counterbalancing the effects of each other. Inhibition of ACE has been shown to improve pathology in cardiovascular disease, whilst ACE2 is cardioprotective in the failing heart. However, the mechanisms by which ACE2 mediates its cardioprotective functions have yet to be fully elucidated. Here we demonstrate that both ACE and ACE2 bind integrin subunits, in an RGD-independent manner, and that they can act as cell adhesion substrates. We show that cellular expression of ACE2 enhanced cell adhesion. Furthermore, we present evidence that soluble ACE2 (sACE2 is capable of suppressing integrin signalling mediated by FAK. In addition, sACE2 increases the expression of Akt, thereby lowering the proportion of the signalling molecule phosphorylated Akt. These results suggest that ACE2 plays a role in cell-cell interactions, possibly acting to fine-tune integrin signalling. Hence the expression and cleavage of ACE2 at the plasma membrane may influence cell-extracellular matrix interactions and the signalling that mediates cell survival and proliferation. As such, ectodomain shedding of ACE2 may play a role in the process of pathological cardiac remodelling.

  7. Exploring the Link between ACE Insertion/Deletion (I/D Polymorphism and Uterine Leiomyomas

    Directory of Open Access Journals (Sweden)

    Shirin Shahbazi

    2017-03-01

    Full Text Available Introduction: Uterine leiomyomas arise from the proliferation of smooth muscle cells. ACE gene encodes a convertase enzyme mainly secreted in vascular endothelial cells which is involved in the renin–angiotensin system and blood pressure controlling. This gene has an insertion/deletion (I/D polymorphism correlates to serum and tissue ACE levels. The aim of this study is to elucidate the relationship between ACE gene variation and the development of myom. Methods: The samples of 55 uterine leiomyoma patients and 78 healthy women were studied. After obtaining informed consent, blood samples were collected and DNA extraction was performed by Salting-out method. Genotyping was performed using PCR reaction. The amplified products were two bands of 190 and 490 bp, which represents D allele and I allele, respectively. Statistical analysis was done using Chi-square test. Results: The D allele frequency was 0.55 in the patient group and 0.51 in the control group. The I allele frequencies in the two groups were 0.45 and 0.49, respectively. The results showed that taking the II genotype into account as reference genotype; homozygous DD individuals were at increased risk of uterine myoma (Odds ratio: 1.37. However, heterozygous ID showed a similar risk with the II genotype as the reference group. Conclusion: High blood pressure is significantly associated with uterine fibroids. It has been shown that atherosclerotic damage of uterine blood vessels and the inflammatory process caused by it may play an important role in the development of uterine myoma. This study indicates a positive relationship between the ACE (I/D polymorphism and the risk of uterine myoma. This finding is evidence of the important role of the renin–angiotensin system in the pathogenesis of myoma

  8. Improving PET Quantification of Small Animal [68Ga]DOTA-Labeled PET/CT Studies by Using a CT-Based Positron Range Correction.

    Science.gov (United States)

    Cal-Gonzalez, Jacobo; Vaquero, Juan José; Herraiz, Joaquín L; Pérez-Liva, Mailyn; Soto-Montenegro, María Luisa; Peña-Zalbidea, Santiago; Desco, Manuel; Udías, José Manuel

    2018-01-19

    Image quality of positron emission tomography (PET) tracers that emits high-energy positrons, such as Ga-68, Rb-82, or I-124, is significantly affected by positron range (PR) effects. PR effects are especially important in small animal PET studies, since they can limit spatial resolution and quantitative accuracy of the images. Since generators accessibility has made Ga-68 tracers wide available, the aim of this study is to show how the quantitative results of [ 68 Ga]DOTA-labeled PET/X-ray computed tomography (CT) imaging of neuroendocrine tumors in mice can be improved using positron range correction (PRC). Eighteen scans in 12 mice were evaluated, with three different models of tumors: PC12, AR42J, and meningiomas. In addition, three different [ 68 Ga]DOTA-labeled radiotracers were used to evaluate the PRC with different tracer distributions: [ 68 Ga]DOTANOC, [ 68 Ga]DOTATOC, and [ 68 Ga]DOTATATE. Two PRC methods were evaluated: a tissue-dependent (TD-PRC) and a tissue-dependent spatially-variant correction (TDSV-PRC). Taking a region in the liver as reference, the tissue-to-liver ratio values for tumor tissue (TLR tumor ), lung (TLR lung ), and necrotic areas within the tumors (TLR necrotic ) and their respective relative variations (ΔTLR) were evaluated. All TLR values in the PRC images were significantly different (p DOTA-labeled PET/CT imaging of mice with neuroendocrine tumors, hence demonstrating that these techniques could also ameliorate the deleterious effect of the positron range in clinical PET imaging.

  9. Role of ACE and IL-1β Gene Polymorphisms in Erythropoeitin Hyporesponsive Patients with Chronic Kidney Disease with Anemia.

    Science.gov (United States)

    Nand, N; Deshmukh, A R; Joshi, S; Sachdeva, M P; Sakthivel

    2017-02-01

    Hyporesponse to erythropoietin is a common problem seen in around 5-10% of patients. Recently the focus from these remediable factors has been shifted to the non-modifiable innate factors i.e polymorphism of ACE and IL-1B gene and studies have shown that DD genotype and IL-1B CC genotype have lower erythropoietin requirement. The aim of our study was to evaluate the role of ACE and IL-1B gene polymorphisms in erythropoietin hyporesponse in CKD patients with anemia. A total of 50 patients were selected. After taking pre-informed written consent, they were segregated into two groups, group A and B with 25 patients in each group. Group A included CKD stage III-IV patients and Group B included CKD stage V patients who were on regular maintenance. All patients were given erythroepoietin and response was monitored using erythropoietin resistance index (ERI). Genotyping of ACE and IL-1B genes were done and serum levels of ACE and IL-1B were measured. Mean values of ERI were compared between different genotype subgroups and analysed using binary regression analysis. The study group included 6 patients with diabetic nephropathy and out of these 4(66.6%) had DD genotype. On comparing the effect of ACE polymorphism on ERI levels it was seen that the mean ERI values in DD subgroup were significantly lower (16.97±5.35, 21.88±6.25, 22.69±8.35 at 1,3 and 5th month) as compared to ID (18.16±3.39, 24.17±3.66, 32.74±9.95 and II (20.73±5.17, 27.74±7.30, 41.08±13.83 U/Kg/g/dL). In the case of IL-1B the mean ERI values were lowest in the TT subgroup (16.46±4.45, 21.96±5.77,23.98±8.48) as compared to CC (19.49 ±5.62,25.46±7.07, 33.59±12.61) and CT (18.12±4.27,24.14±5.70, 31.89±13.83 U/Kg/g/dL). The mean serum values of ACE were in a decreasing trend i.e DD> ID> II (238.05 ± 52.46, 194.73±50.28 and 162.99±39.71 ng/ml, (p 0.05). D allele positively affected the serum ACE level but there was no association between IL-1B genotype and its levels. ACE gene polymorphism

  10. Event-by-Event Continuous Respiratory Motion Correction for Dynamic PET Imaging.

    Science.gov (United States)

    Yu, Yunhan; Chan, Chung; Ma, Tianyu; Liu, Yaqiang; Gallezot, Jean-Dominique; Naganawa, Mika; Kelada, Olivia J; Germino, Mary; Sinusas, Albert J; Carson, Richard E; Liu, Chi

    2016-07-01

    Existing respiratory motion-correction methods are applied only to static PET imaging. We have previously developed an event-by-event respiratory motion-correction method with correlations between internal organ motion and external respiratory signals (INTEX). This method is uniquely appropriate for dynamic imaging because it corrects motion for each time point. In this study, we applied INTEX to human dynamic PET studies with various tracers and investigated the impact on kinetic parameter estimation. The use of 3 tracers-a myocardial perfusion tracer, (82)Rb (n = 7); a pancreatic β-cell tracer, (18)F-FP(+)DTBZ (n = 4); and a tumor hypoxia tracer, (18)F-fluoromisonidazole ((18)F-FMISO) (n = 1)-was investigated in a study of 12 human subjects. Both rest and stress studies were performed for (82)Rb. The Anzai belt system was used to record respiratory motion. Three-dimensional internal organ motion in high temporal resolution was calculated by INTEX to guide event-by-event respiratory motion correction of target organs in each dynamic frame. Time-activity curves of regions of interest drawn based on end-expiration PET images were obtained. For (82)Rb studies, K1 was obtained with a 1-tissue model using a left-ventricle input function. Rest-stress myocardial blood flow (MBF) and coronary flow reserve (CFR) were determined. For (18)F-FP(+)DTBZ studies, the total volume of distribution was estimated with arterial input functions using the multilinear analysis 1 method. For the (18)F-FMISO study, the net uptake rate Ki was obtained with a 2-tissue irreversible model using a left-ventricle input function. All parameters were compared with the values derived without motion correction. With INTEX, K1 and MBF increased by 10% ± 12% and 15% ± 19%, respectively, for (82)Rb stress studies. CFR increased by 19% ± 21%. For studies with motion amplitudes greater than 8 mm (n = 3), K1, MBF, and CFR increased by 20% ± 12%, 30% ± 20%, and 34% ± 23%, respectively. For (82)Rb

  11. Impact of subject head motion on quantitative brain 15O PET and its correction by image-based registration algorithm

    International Nuclear Information System (INIS)

    Matsubara, Keisuke; Ibaraki, Masanobu; Nakamura, Kazuhiro; Yamaguchi, Hiroshi; Umetsu, Atsushi; Kinoshita, Fumiko; Kinoshita, Toshibumi

    2013-01-01

    Subject head motion during sequential 15 O positron emission tomography (PET) scans can result in artifacts in cerebral blood flow (CBF) and oxygen metabolism maps. However, to our knowledge, there are no systematic studies examining this issue. Herein, we investigated the effect of head motion on quantification of CBF and oxygen metabolism, and proposed an image-based motion correction method dedicated to 15 O PET study, correcting for transmission-emission mismatch and inter-scan mismatch of emission scans. We analyzed 15 O PET data for patients with major arterial steno-occlusive disease (n=130) to determine the occurrence frequency of head motion during 15 O PET examination. Image-based motion correction without and with realignment between transmission and emission scans, termed simple and 2-step method, respectively, was applied to the cases that showed severe inter-scan motion. Severe inter-scan motion (>3 mm translation or >5deg rotation) was observed in 27 of 520 adjacent scan pairs (5.2%). In these cases, unrealistic values of oxygen extraction fraction (OEF) or cerebrovascular reactivity (CVR) were observed without motion correction. Motion correction eliminated these artifacts. The volume-of-interest (VOI) analysis demonstrated that the motion correction changed the OEF on the middle cerebral artery territory by 17.3% at maximum. The inter-scan motion also affected cerebral blood volume (CBV), cerebral metabolism rate of oxygen (CMRO 2 ) and CBF, which were improved by the motion correction. A difference of VOI values between the simple and 2-step method was also observed. These data suggest that image-based motion correction is useful for accurate measurement of CBF and oxygen metabolism by 15 O PET. (author)

  12. Head and neck imaging with PET and PET/CT: artefacts from dental metallic implants

    International Nuclear Information System (INIS)

    Goerres, Gerhard W.; Hany, Thomas F.; Kamel, Ehab; Schulthess von, Gustav K.; Buck, Alfred

    2002-01-01

    Germanium-68 based attenuation correction (PET Ge68 ) is performed in positron emission tomography (PET) imaging for quantitative measurements. With the recent introduction of combined in-line PET/CT scanners, CT data can be used for attenuation correction. Since dental implants can cause artefacts in CT images, CT-based attenuation correction (PET CT ) may induce artefacts in PET images. The purpose of this study was to evaluate the influence of dental metallic artwork on the quality of PET images by comparing non-corrected images and images attenuation corrected by PET Ge68 and PET CT . Imaging was performed on a novel in-line PET/CT system using a 40-mAs scan for PET CT in 41 consecutive patients with high suspicion of malignant or inflammatory disease. In 17 patients, additional PET Ge68 images were acquired in the same imaging session. Visual analysis of fluorine-18 fluorodeoxyglucose (FDG) distribution in several regions of the head and neck was scored on a 4-point scale in comparison with normal grey matter of the brain in the corresponding PET images. In addition, artefacts adjacent to dental metallic artwork were evaluated. A significant difference in image quality scoring was found only for the lips and the tip of the nose, which appeared darker on non-corrected than on corrected PET images. In 33 patients, artefacts were seen on CT, and in 28 of these patients, artefacts were also seen on PET imaging. In eight patients without implants, artefacts were seen neither on CT nor on PET images. Direct comparison of PET Ge68 and PET CT images showed a different appearance of artefacts in 3 of 17 patients. Malignant lesions were equally well visible using both transmission correction methods. Dental implants, non-removable bridgework etc. can cause artefacts in attenuation-corrected images using either a conventional 68 Ge transmission source or the CT scan obtained with a combined PET/CT camera. We recommend that the non-attenuation-corrected PET images also be

  13. Errors in MR-based attenuation correction for brain imaging with PET/MR scanners

    International Nuclear Information System (INIS)

    Rota Kops, Elena; Herzog, Hans

    2013-01-01

    Aim: Attenuation correction of PET data acquired by hybrid MR/PET scanners remains a challenge, even if several methods for brain and whole-body measurements have been developed recently. A template-based attenuation correction for brain imaging proposed by our group is easy to handle and delivers reliable attenuation maps in a short time. However, some potential error sources are analyzed in this study. We investigated the choice of template reference head among all the available data (error A), and possible skull anomalies of the specific patient, such as discontinuities due to surgery (error B). Materials and methods: An anatomical MR measurement and a 2-bed-position transmission scan covering the whole head and neck region were performed in eight normal subjects (4 females, 4 males). Error A: Taking alternatively one of the eight heads as reference, eight different templates were created by nonlinearly registering the images to the reference and calculating the average. Eight patients (4 females, 4 males; 4 with brain lesions, 4 w/o brain lesions) were measured in the Siemens BrainPET/MR scanner. The eight templates were used to generate the patients' attenuation maps required for reconstruction. ROI and VOI atlas-based comparisons were performed employing all the reconstructed images. Error B: CT-based attenuation maps of two volunteers were manipulated by manually inserting several skull lesions and filling a nasal cavity. The corresponding attenuation coefficients were substituted with the water's coefficient (0.096/cm). Results: Error A: The mean SUVs over the eight templates pairs for all eight patients and all VOIs did not differ significantly one from each other. Standard deviations up to 1.24% were found. Error B: After reconstruction of the volunteers' BrainPET data with the CT-based attenuation maps without and with skull anomalies, a VOI-atlas analysis was performed revealing very little influence of the skull lesions (less than 3%), while the filled

  14. Errors in MR-based attenuation correction for brain imaging with PET/MR scanners

    Science.gov (United States)

    Rota Kops, Elena; Herzog, Hans

    2013-02-01

    AimAttenuation correction of PET data acquired by hybrid MR/PET scanners remains a challenge, even if several methods for brain and whole-body measurements have been developed recently. A template-based attenuation correction for brain imaging proposed by our group is easy to handle and delivers reliable attenuation maps in a short time. However, some potential error sources are analyzed in this study. We investigated the choice of template reference head among all the available data (error A), and possible skull anomalies of the specific patient, such as discontinuities due to surgery (error B). Materials and methodsAn anatomical MR measurement and a 2-bed-position transmission scan covering the whole head and neck region were performed in eight normal subjects (4 females, 4 males). Error A: Taking alternatively one of the eight heads as reference, eight different templates were created by nonlinearly registering the images to the reference and calculating the average. Eight patients (4 females, 4 males; 4 with brain lesions, 4 w/o brain lesions) were measured in the Siemens BrainPET/MR scanner. The eight templates were used to generate the patients' attenuation maps required for reconstruction. ROI and VOI atlas-based comparisons were performed employing all the reconstructed images. Error B: CT-based attenuation maps of two volunteers were manipulated by manually inserting several skull lesions and filling a nasal cavity. The corresponding attenuation coefficients were substituted with the water's coefficient (0.096/cm). ResultsError A: The mean SUVs over the eight templates pairs for all eight patients and all VOIs did not differ significantly one from each other. Standard deviations up to 1.24% were found. Error B: After reconstruction of the volunteers' BrainPET data with the CT-based attenuation maps without and with skull anomalies, a VOI-atlas analysis was performed revealing very little influence of the skull lesions (less than 3%), while the filled nasal

  15. ACE I/D Gene Polymorphism Can't Predict the Steroid Responsiveness in Asian Children with Idiopathic Nephrotic Syndrome: A Meta-Analysis

    Science.gov (United States)

    Su, Li-Na; Lei, Feng-Ying; Huang, Wei-Fang; Zhao, Yan-Jun

    2011-01-01

    Background The results from the published studies on the association between angiotensin-converting enzyme (ACE) insertion/deletion (I/D) gene polymorphism and the treatment response to steroid in Asian children with idiopathic nephrotic syndrome (INS) is still conflicting. This meta-analysis was performed to evaluate the relation between ACE I/D gene polymorphism and treatment response to steroid in Asian children and to explore whether ACE D allele or DD genotype could become a predictive marker for steroid responsiveness. Methodology/Principal Findings Association studies were identified from the databases of PubMed, Embase, Cochrane Library and CBM-disc (China Biological Medicine Database) as of September 1, 2010, and eligible investigations were synthesized using meta-analysis method. Five investigations were identified for the analysis of association between ACE I/D gene polymorphism and steroid-resistant nephrotic syndrome (SRNS) risk in Asian children and seven studies were included to explore the relationship between ACE I/D gene polymorphism and steroid-sensitive nephrotic syndrome (SSNS) susceptibility. Five investigations were recruited to explore the difference of ACE I/D gene distribution between SRNS and SSNS. There was no a markedly association between D allele or DD genotype and SRNS susceptibility or SSNS risk, and the gene distribution differences of ACE between SRNS and SSNS were not statistically significant. II genotype might play a positive role against SRNS onset but not for SSNS (OR = 0.51, P = 0.02; OR = 0.95, P = 0.85; respectively), however, the result for the association of II genotype with SRNS risk was not stable. Conclusions/Significance Our results indicate that D allele or DD homozygous can't become a significant genetic molecular marker to predict the treatment response to steroid in Asian children with INS. PMID:21611163

  16. Value of a dixon-based MR/PET attenuation correction sequence for the localization and evaluation of PET-positive lesions

    International Nuclear Information System (INIS)

    Eiber, Matthias; Holzapfel, Konstantin; Rummeny, Ernst J.; Martinez-Moeller, Axel; Souvatzoglou, Michael; Ziegler, Sibylle; Schwaiger, Markus; Nekolla, Stephan G.; Beer, Ambros J.; Pickhard, Anja; Loeffelbein, Dennys; Santi, Ivan

    2011-01-01

    In this study, the potential contribution of Dixon-based MR imaging with a rapid low-resolution breath-hold sequence, which is a technique used for MR-based attenuation correction (AC) for MR/positron emission tomography (PET), was evaluated for anatomical correlation of PET-positive lesions on a 3T clinical scanner compared to low-dose CT. This technique is also used in a recently installed fully integrated whole-body MR/PET system. Thirty-five patients routinely scheduled for oncological staging underwent 18 F-fluorodeoxyglucose (FDG) PET/CT and a 2-point Dixon 3-D volumetric interpolated breath-hold examination (VIBE) T1-weighted MR sequence on the same day. Two PET data sets reconstructed using attenuation maps from low-dose CT (PET AC C T ) or simulated MR-based segmentation (PET AC M R ) were evaluated for focal PET-positive lesions. The certainty for the correlation with anatomical structures was judged in the low-dose CT and Dixon-based MRI on a 4-point scale (0-3). In addition, the standardized uptake values (SUVs) for PET AC C T and PET AC M R were compared. Statistically, no significant difference could be found concerning anatomical localization for all 81 PET-positive lesions in low-dose CT compared to Dixon-based MR (mean 2.51 ± 0.85 and 2.37 ± 0.87, respectively; p = 0.1909). CT tended to be superior for small lymph nodes, bone metastases and pulmonary nodules, while Dixon-based MR proved advantageous for soft tissue pathologies like head/neck tumours and liver metastases. For the PET AC C T - and PET AC M R -based SUVs (mean 6.36 ± 4.47 and 6.31 ± 4.52, respectively) a nearly complete concordance with a highly significant correlation was found (r = 0.9975, p < 0.0001). Dixon-based MR imaging for MR AC allows for anatomical allocation of PET-positive lesions similar to low-dose CT in conventional PET/CT. Thus, this approach appears to be useful for future MR/PET for body regions not fully covered by diagnostic MRI due to potential time

  17. Effect of ACE insertion/deletion and 12 other polymorphisms on clinical outcomes and response to treatment in the life study

    DEFF Research Database (Denmark)

    Nordestgaard, Børge G; Kontula, Kimmo; Benn, Marianne

    2010-01-01

    whether the insertion/deletion (I/D) polymorphism of the angiotensin-converting enzyme (ACE) gene and 12 other previously well-characterized polymorphisms of hypertension susceptibility genes affected blood pressure reduction, heart rate reduction, cardiovascular events, and/or response to treatment...... in the Losartan Intervention for Endpoint reduction in hypertension study do not depend on ACE and 12 other polymorphisms of hypertension susceptibility genes........ These polymorphisms were chosen because they could affect blood pressure control or the pharmacological action of losartan or atenolol. METHODS: We genotyped 3503 patients, 1774 on losartan and 1729 on atenolol. RESULTS: ACE and the 12 other genotypes did not affect the reduction in systolic blood pressure, diastolic...

  18. Role of ACE and AGT gene polymorphisms in genetic susceptibility to diabetes mellitus type 2 in a Brazilian sample.

    Science.gov (United States)

    Wollinger, L M; Dal Bosco, S M; Rempe, C; Almeida, S E M; Berlese, D B; Castoldi, R P; Arndt, M E; Contini, V; Genro, J P

    2015-12-29

    The aim of the current study was to investigate the association between the InDel polymorphism in the angiotensin I-converting enzyme gene (ACE) and the rs699 polymorphism in the angiotensinogen gene (AGT) and diabetes mellitus type 2 (DM2) in a sample population from Southern Brazil. A case-control study was conducted with 228 patients with DM2 and 183 controls without DM2. The ACE InDel polymorphism was genotyped by polymerase chain reaction (PCR) with specific primers, followed by electrophoresis on 1.5% agarose gel. The AGT rs699 polymorphism was genotyped using a real-time PCR assay. No significant association between the ACE InDel polymorphism and DM2 was detected (P = 0.97). However, regarding the AGT rs699 polymorphism, DM2 patients had a significantly higher frequency of the AG genotype and lower frequency of the GG genotype when compared to the controls (P = 0.03). Our results suggest that there is an association between the AGT rs699 polymorphism and DM2 in a Brazilian sample.

  19. Fine-Mapping Angiotensin-Converting Enzyme Gene: Separate QTLs Identified for Hypertension and for ACE Activity

    Science.gov (United States)

    Chung, Chia-Min; Wang, Ruey-Yun; Fann, Cathy S. J.; Chen, Jaw-Wen; Jong, Yuh-Shiun; Jou, Yuh-Shan; Yang, Hsin-Chou; Kang, Chih-Sen; Chen, Chien-Chung; Chang, Huan-Cheng; Pan, Wen-Harn

    2013-01-01

    Angiotensin-converting enzyme (ACE) has been implicated in multiple biological system, particularly cardiovascular diseases. However, findings associating ACE insertion/deletion polymorphism with hypertension or other related traits are inconsistent. Therefore, in a two-stage approach, we aimed to fine-map ACE in order to narrow-down the function-specific locations. We genotyped 31 single nucleotide polymorphisms (SNPs) of ACE from 1168 individuals from 305 young-onset (age ≤40) hypertension pedigrees, and found four linkage disequilibrium (LD) blocks. A tag-SNP, rs1800764 on LD block 2, upstream of and near the ACE promoter, was significantly associated with young-onset hypertension (p = 0.04). Tag-SNPs on all LD blocks were significantly associated with ACE activity (p-value: 10–16 to ACE activity were found between exon13 and intron18 and between intron 20 and 3′UTR, as revealed by measured haplotype analysis. These two major QTLs of ACE activity and the moderate effect variant upstream of ACE promoter for young-onset hypertension were replicated by another independent association study with 842 subjects. PMID:23469169

  20. Association of AGTR1 (A1166C and ACE (I/D Polymorphisms with Breast Cancer Risk in North Indian Population

    Directory of Open Access Journals (Sweden)

    Anukriti Singh

    2018-04-01

    Full Text Available Renin angiotensin system (RAS comprising Angiotensin converting enzyme (ACE, Angiotensin II (Ang II and its receptor Angiotensin II receptor type I (AGTR1, plays a critical role in several diseases including cancer. A single nucleotide polymorphism (SNP A1166C located in 3′ untranslated region (UTR of AGTR1 and an insertion/deletion (I/D polymorphism present in intron 16 of ACE gene have been associated with many diseases, but their association with Breast cancer (BCa is still debatable. Here, we for the first time investigated the association of these polymorphisms in a North Indian BCa cohort including 161 patients and 152 healthy women. The polymorphisms were evaluated by polymerase chain reaction (PCR and restriction fragment length polymorphism (RFLP respectively. The association between these polymorphisms and BCa risk was estimated by calculating Odds Ratio (OR and chi-square (χ2 test. The DD genotype/D allele of ACE (I/D polymorphism and “AC and CC” genotype/C allele of AGTR1 (A1166C polymorphism were associated with higher risk of BCa when evaluated independently. Furthermore, interaction analysis of “AC and CC” and DD genotype and combination of “C and D” alleles of both polymorphisms revealed significantly greater BCa risk than that observed independently. Conclusively, women harboring “AC or CC” genotype/C allele for AGTR1 (A1166C polymorphism and DD genotype/D allele for ACE (I/D polymorphisms have a predisposition to develop more aggressive disease with advanced staging and larger tumor size. Our study indicates importance of genetic screening based on these polymorphisms for women, who may have higher risk of BCa.

  1. The influence of a polymorphism in the gene encoding angiotensin converting enzyme (ACE on treatment outcomes in late-onset Pompe patients receiving alglucosidase alfa

    Directory of Open Access Journals (Sweden)

    Rena C. Baek

    2016-09-01

    Full Text Available Correlations between angiotensin-converting enzyme (ACE genotype (I/I, I/D, D/D, disease severity at baseline and response to enzyme replacement therapy (ERT were assessed in the Pompe disease Late-Onset Treatment Study (LOTS. No correlations were observed between ACE genotype and disease severity at baseline. However, D/D patients appeared to have a reduced response to alglucosidase alfa treatment than I/I or I/D patients, suggesting that ACE polymorphisms may influence the response to alglucosidase alfa treatment and warrants further investigation.

  2. Localization of Epileptogenic Zones using Partical Volume Corrected FDG Uptake on FDG PET and Voxel Based Morphometry on MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Won Jun; Lee, Ho Young; Lee, Jae Sung; Lee, Dong Soo; Lee, Sang Kun; Chung, June Key; Lee, Myung Chul [College of Medicine, Univ. of Seoul National, Seoul (Korea, Republic of)

    2003-07-01

    Partial volume corrected (PVC) FDG uptake yields information about regional metabolic level void of volume change, and voxel based morphometry (VBM) yields objective information regarding gray matter concentration. We investigated the roles of PVC PET and VBM to localize epileptogenic zones in medial temporal lobe epilepsy (mTLE) and non-lesional neocortical epilepsy. As a control group for PVC, 40 normal volunteers without history of neurologic or psychiatric diseases underwent FDG PET and MRI. Seventeen mTLE patients (M: F=7: 10, age=309 y) and nine neocortical epilepsy patients (M: F=6: 3, age=246, lateral temporal: 5, frontal: 3, occipital: 1) confirmed by surgery or epilepsy board meeting were enrolled. Standard VBM analysis was performed using individual MRI images compared with those of age-matched controls. For PVC, FDG PET was co-registered with its own MRI. PVC PET was obtained by dividing spillover-corrected PET by smoothed gray matter image pixel by pixel. SPAM was applied as a mask of volume of interest (VOI) to calculate gyral FDG uptake on PVC-FDG PET. Hippocampus, amygdala, superior, middle, inferior temporal gyrus and parahippocampal gyrus were the gyral SPAM VOIs in mTLE. Globally normalized PVC-FDG counts were compared with those of age-matched controls in mTLE and neocortical epilepsy patients. In mTlE, PVC-FDG PET correctly localized epileptogenic zones with the accuracy of 76% (13/17) in hippocampus and 82% (14/17) in any of six regions. VBM correctly localized 59% (10/17) in mTLE. In neocortical epilepsy, PVC-FDG PET localized epileptogenic zones in 44%, and VBM in 33%, Using VBM and PVC-FDG PET altogether, epileptogenic zones were localized in 66% (6/9). In mTLE, gyral PVC FDG uptake of temporal lobes was useful in localizing epileptogenic zones by demonstrating partial volume-void FDG concentration. In non-lesional cryptogenic neocortical epilepsy, combination of PVC-FDG PET and VBM is recommended to localize epileptogenic zones.

  3. Prevalence of alpha actinin-3 gene (ACTN3) R577X and angiotensin converting enzyme (ACE) insertion / deletion gene polymorphisms in national and amateur Turkish athletes.

    Science.gov (United States)

    Eroğlu, Onur; Zileli, Rayif; Nalbant, M Ali; Ulucan, Korkut

    2018-04-30

    Studies to date showed the importance of alpha- actinin-3 (ACTN3) R577X and angiotensin converting enzyme (ACE) ID polymorphisms on determining athletic performance. Therefore, in this study, we aimed to examine polymorphisms given to Turkish athletes and compare them with sedentary individuals. Genomic DNAs were extracted from peripheral blood by using commercially available DNA isolation kit (Macherey-Nagel, NucleoSpin®, Germany). For this study, a total of 84 volunteers (23 national athletes, 27 amateur athletes and 34 sedentary controls) was recruited.  ACE ID genotypes were determined by conventional polymerase chain reaction, and ACTN3 R577X polymorphisms by polymerase chain reaction- restriction fragment length polymorphism methodology.   In ACTN3 R577X polymorphism, RX was the dominating genotype, and we detected no RR genotype in national athletes. (no RR genotype was detected in national athletes) X allele is more frequent in national athletes and R allele was more frequent in both amateur athletes and control group. II genotype was more frequent in national athletes and in control group, whereas DD genotype was more frequent in amateur athletes for ACE ID polymorphism. When we consider alleles, D allele was found more frequently in amateur athletes and control group whereas I allele was more frequent in national athletes in ACE ID polymorphism. For ACTN3, X allele was superior to R allele. ACTN3 R577X and ACE ID polymorphisms were important biomarkers in determining athletic performance. However, our results in Turkish athletes suggest that ACE D allele and ACTN3 X alleles may be beneficial to athletes potentially, regardless of the distance they perform.

  4. ACE serum level and I/D gene polymorphism in children with obstructive uropathies and other congenital anomalies of the kidney and urinary tract.

    Science.gov (United States)

    Kostadinova, Emilya Stambolova; Miteva, Lyuba Dineva; Stanilova, Spaska Angelova

    2017-08-01

    The aim of this study was to investigate the association of an insertion/deletion (I/D) polymorphism in angiotensin-converting enzyme (ACE) gene with serum ACE level in relation to the type and severity of malformations from congenital anomalies of the kidney and urinary tract (CAKUT) spectrum. A group of 134 Bulgarian children with CAKUT divided into four subgroups according to the leading malformation and 109 controls were genotyped by classical polymerase chain reaction. The quantitative determination of serum ACE was performed by ELISA method. A significant elevation of DD-genotype was observed in high-grade hydronephrosis compared to low-grade (43% vs. 9%). The carrying of DD-genotype was associated with higher risk for severe hydronephrosis with OR = 7.5 (95% CI: 1.242÷45.278; P = 0.028). Also, elevated serum ACE concentrations in patients with high-grade compared to low-grade hydronephrosis (237.4 ± 45 ng/mL vs 180.5 ± 64 ng/mL; P = 0.0065) were found. ACE level was significantly lower in patients with unilateral renal agenesis; hypo/dysplasia and multicystic dysplastic kidney (156.6 ± 54 ng/mL) than controls (200.6 ± 56.7 ng/mL; P = 0.005) and the remaining CAKUT subgroups. The DD genotype of I/D ACE polymorphism encodes the highest serum ACE level may be an additional genetic risk factor contributing to the severe hydronephrosis in Bulgarian patients with obstructive uropathies in contrast to other investigated categories of CAKUT malformations. © 2016 Asian Pacific Society of Nephrology.

  5. ASSOCIATION OF ACTN3 R577X AND ACE I/D POLYMORPHISMS IN BRAZILIANS WRESTLERS

    Directory of Open Access Journals (Sweden)

    Marcelo Romanovitch Ribas

    Full Text Available ABSTRACT Introduction: By associating genetics and sport, it is possible to identify subjects with greater capacity to adapt to training, and lower chances of injury. Objective: The investigation evaluated the genotypic and allelic distribution of ACTN3 R577X and ACE I/D polymorphisms in Brazilian high-performance athletes in wrestling and percussion combat sports. Methods: The study included 37 male athletes ranked from first to third place in world scenarios, divided into two groups: wrestling (23 wrestlers, being 11 of Judo, 4 of Greco-Roman style, 8 of Brazilian Jiu Jitsu, with mean age of 27.3 ± 6.9 years and percussion combat sports (14 athletes with a mean age of 25.7±4.4 years, being 6 of Karate, 3 of Muay Thai, 4 of Taekwondo, 1 Boxing. Genotyping of ACTN3 and ACE I/D polymorphisms was performed by polymerase chain reaction (PCR from the genomic DNA. Genotypic and allelic distributions were compared with control populations and athletes by Chi-square test and Fisher’s exact test; all analyzes considered p ≤ 0.05. Results: The genotypic distributions and allelic frequencies of ACTN3 RR=46%, RX=38% and XX=16%; R=65% and X=35%, and ACE I/D DD=47.7%, ID=34.3% and II=20%; D=62.9% and I=37.1% did not differ from the control population; however, when compared with wrestling athletes a significant difference was observed. Conclusion: These results suggest an association of ACTN3 R577X and ACE I/D genes with Brazilian high-performance wrestling athletes.

  6. Prevalence and Genotyping of Cryptosporidium Infection in Pet Parrots in North China

    Directory of Open Access Journals (Sweden)

    Xiao-Xuan Zhang

    2015-01-01

    Full Text Available Cryptosporidiosis is a worldwide zoonosis caused by Cryptosporidium spp., sometimes leading to severe diarrhea in humans and animals. In the present study, 311 parrots, belonging to four species, namely, Budgerigars (Melopsittacus undulatus, Lovebirds (Agapornis sp., Alexandrine parakeets (Psittacula eupatria, and Cockatiel (Nymphicus hollandicus, from Beijing and Weifang cities, were examined for Cryptosporidium spp. infection. Blood samples of each bird were examined using enzyme linked immunosorbent assay (ELISA and fecal samples were examined by Sheather’s sugar flotation technique. Prevalence of Cryptosporidium infection were 3.22% (10/311 and 0.64% (2/311 by ELISA and Sheather’s sugar flotation technique, respectively. Seroprevalence of Cryptosporidium infection in different breeds varied from 0 to 15.39%. Sequencing analysis showed that both positive samples from fecal samples belonged to Cryptosporidium avian genotype V. This is the first report of Cryptosporidium avian genotype V in Budgerigars. The results of the present study provided foundation-data for prevention and control of cryptosporidiosis in pet birds in China.

  7. Prevalence and Genotyping of Cryptosporidium Infection in Pet Parrots in North China.

    Science.gov (United States)

    Zhang, Xiao-Xuan; Zhang, Nian-Zhang; Zhao, Guang-Hui; Zhao, Quan; Zhu, Xing-Quan

    2015-01-01

    Cryptosporidiosis is a worldwide zoonosis caused by Cryptosporidium spp., sometimes leading to severe diarrhea in humans and animals. In the present study, 311 parrots, belonging to four species, namely, Budgerigars (Melopsittacus undulatus), Lovebirds (Agapornis sp.), Alexandrine parakeets (Psittacula eupatria), and Cockatiel (Nymphicus hollandicus), from Beijing and Weifang cities, were examined for Cryptosporidium spp. infection. Blood samples of each bird were examined using enzyme linked immunosorbent assay (ELISA) and fecal samples were examined by Sheather's sugar flotation technique. Prevalence of Cryptosporidium infection were 3.22% (10/311) and 0.64% (2/311) by ELISA and Sheather's sugar flotation technique, respectively. Seroprevalence of Cryptosporidium infection in different breeds varied from 0 to 15.39%. Sequencing analysis showed that both positive samples from fecal samples belonged to Cryptosporidium avian genotype V. This is the first report of Cryptosporidium avian genotype V in Budgerigars. The results of the present study provided foundation-data for prevention and control of cryptosporidiosis in pet birds in China.

  8. Dynamic PET image reconstruction integrating temporal regularization associated with respiratory motion correction for applications in oncology

    Science.gov (United States)

    Merlin, Thibaut; Visvikis, Dimitris; Fernandez, Philippe; Lamare, Frédéric

    2018-02-01

    Respiratory motion reduces both the qualitative and quantitative accuracy of PET images in oncology. This impact is more significant for quantitative applications based on kinetic modeling, where dynamic acquisitions are associated with limited statistics due to the necessity of enhanced temporal resolution. The aim of this study is to address these drawbacks, by combining a respiratory motion correction approach with temporal regularization in a unique reconstruction algorithm for dynamic PET imaging. Elastic transformation parameters for the motion correction are estimated from the non-attenuation-corrected PET images. The derived displacement matrices are subsequently used in a list-mode based OSEM reconstruction algorithm integrating a temporal regularization between the 3D dynamic PET frames, based on temporal basis functions. These functions are simultaneously estimated at each iteration, along with their relative coefficients for each image voxel. Quantitative evaluation has been performed using dynamic FDG PET/CT acquisitions of lung cancer patients acquired on a GE DRX system. The performance of the proposed method is compared with that of a standard multi-frame OSEM reconstruction algorithm. The proposed method achieved substantial improvements in terms of noise reduction while accounting for loss of contrast due to respiratory motion. Results on simulated data showed that the proposed 4D algorithms led to bias reduction values up to 40% in both tumor and blood regions for similar standard deviation levels, in comparison with a standard 3D reconstruction. Patlak parameter estimations on reconstructed images with the proposed reconstruction methods resulted in 30% and 40% bias reduction in the tumor and lung region respectively for the Patlak slope, and a 30% bias reduction for the intercept in the tumor region (a similar Patlak intercept was achieved in the lung area). Incorporation of the respiratory motion correction using an elastic model along with a

  9. Fuzzy clustering-based segmented attenuation correction in whole-body PET

    CERN Document Server

    Zaidi, H; Boudraa, A; Slosman, DO

    2001-01-01

    Segmented-based attenuation correction is now a widely accepted technique to reduce noise contribution of measured attenuation correction. In this paper, we present a new method for segmenting transmission images in positron emission tomography. This reduces the noise on the correction maps while still correcting for differing attenuation coefficients of specific tissues. Based on the Fuzzy C-Means (FCM) algorithm, the method segments the PET transmission images into a given number of clusters to extract specific areas of differing attenuation such as air, the lungs and soft tissue, preceded by a median filtering procedure. The reconstructed transmission image voxels are therefore segmented into populations of uniform attenuation based on the human anatomy. The clustering procedure starts with an over-specified number of clusters followed by a merging process to group clusters with similar properties and remove some undesired substructures using anatomical knowledge. The method is unsupervised, adaptive and a...

  10. A Movable Phantom Design for Quantitative Evaluation of Motion Correction Studies on High Resolution PET Scanners

    DEFF Research Database (Denmark)

    Olesen, Oline Vinter; Svarer, C.; Sibomana, M.

    2010-01-01

    maximization algorithm with modeling of the point spread function (3DOSEM-PSF), and they were corrected for motions based on external tracking information using the Polaris Vicra real-time stereo motion-tracking system. The new automatic, movable phantom has a robust design and is a potential quality......Head movements during brain imaging using high resolution positron emission tomography (PET) impair the image quality which, along with the improvement of the spatial resolution of PET scanners, in general, raises the importance of motion correction. Here, we present a new design for an automatic...

  11. Local respiratory motion correction for PET/CT imaging: Application to lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lamare, F., E-mail: frederic.lamare@chu-bordeaux.fr; Fernandez, P. [INCIA, UMR 5287, University of Bordeaux, Talence F-33400, France and Nuclear Medicine Department, University Hospital, Bordeaux 33000 (France); Fayad, H.; Visvikis, D. [INSERM, UMR1101, LaTIM, Université de Bretagne Occidentale, Brest 29609 (France)

    2015-10-15

    Purpose: Despite multiple methodologies already proposed to correct respiratory motion in the whole PET imaging field of view (FOV), such approaches have not found wide acceptance in clinical routine. An alternative can be the local respiratory motion correction (LRMC) of data corresponding to a given volume of interest (VOI: organ or tumor). Advantages of LRMC include the use of a simple motion model, faster execution times, and organ specific motion correction. The purpose of this study was to evaluate the performance of LMRC using various motion models for oncology (lung lesion) applications. Methods: Both simulated (NURBS based 4D cardiac-torso phantom) and clinical studies (six patients) were used in the evaluation of the proposed LRMC approach. PET data were acquired in list-mode and synchronized with respiration. The implemented approach consists first in defining a VOI on the reconstructed motion average image. Gated PET images of the VOI are subsequently reconstructed using only lines of response passing through the selected VOI and are used in combination with a center of gravity or an affine/elastic registration algorithm to derive the transformation maps corresponding to the respiration effects. Those are finally integrated in the reconstruction process to produce a motion free image over the lesion regions. Results: Although the center of gravity or affine algorithm achieved similar performance for individual lesion motion correction, the elastic model, applied either locally or to the whole FOV, led to an overall superior performance. The spatial tumor location was altered by 89% and 81% for the elastic model applied locally or to the whole FOV, respectively (compared to 44% and 39% for the center of gravity and affine models, respectively). This resulted in similar associated overall tumor volume changes of 84% and 80%, respectively (compared to 75% and 71% for the center of gravity and affine models, respectively). The application of the nonrigid

  12. Individual and combined influence of ACE and ACTN3 genes on muscle phenotypes in Polish athletes.

    Science.gov (United States)

    Orysiak, Joanna; Mazur-Różycka, Joanna; Busko, Krzysztof; Gajewski, Jan; Szczepanska, Beata; Malczewska-Lenczowska, Jadwiga

    2017-02-08

    The aim of this study was to examine the association between ACE and ACTN3 genes, independently or in combination, and muscle strength and power in male and female athletes. The study involved 398 young male (n=266) and female (n=132) athletes representing various sport disciplines (ice hockey, canoeing, swimming, volleyball). All were Caucasians. The following measurements were taken: height of jump and mechanical power in countermovement jump (CMJ) and spike jump (SPJ), and muscle strength of 10 muscle groups (flexors and extensors of the elbow, shoulder, hip, knee and trunk). The ID polymorphism of ACE and the R577X polymorphism of ACTN3 were typed using PCR (polymerase chain reaction) and PCR-RFLP (polymerase chain reaction - restriction fragment length polymorphism), respectively. The genotype distribution of the ACE and ACTN3 genes did not differ significantly between groups of athletes for either sex. There was no association between ACE and ACTN3 genotypes (alone or in combination) and sum of muscle strength, height of jump or mechanical power in both jump tests (CMJ and SPJ) for male and female athletes. These findings do not support an influential role of the ACE and ACTN3 genes in determining power/strength performance of elite athletes.

  13. Beneficial role of D allele in controlling ACE levels: a study among Brahmins of north India.

    Science.gov (United States)

    Kumari, Shobha; Sharma, Nidhi; Thakur, Sunil; Mondal, Prakash R; Saraswathy, Kallur N

    2016-06-01

    India being a country with vast diversity is expected to have different dietary and life style patterns which in turn may lead to population-specific environmental risk factors. Further, the interaction of these risk factors with the genetic makeup of population makes it either susceptible or resistant to cardiovascular disease. One such candidate gene is angiotensin converting enzyme (ACE) for various cardiovascular mechanisms. ACE is the key enzyme of the renin angiotensin aldosterone system pathway which maintains homeostasis blood pressure in the body and any variation in the levels is reported to be associated with various complex diseases. The DD genotype is found to increase ACE levels, which is associated with cardiovascular diseases and decrease in ACE levels are associated with kidney diseases. The aim of this study was to understand the distribution of ACE I/D polymorphism and ACE levels among Brahmins of National Capital Region (NCR) north India, with respect to age and sex ratio distribution. In this study, 136 subjects of which 50 males and 86 females, who were unrelated up to first cousin, aged 25 to70 years were studied. ACE gene was found to be polymorphic with high frequency of heterozygote (ID) followed by II and DD genotypes. The studied population was found to be in Hardy-Weinberg equilibrium with respect to ACE I/D polymorphism (P = 0.55). I allele frequency was found to be higher (0.560) than the D allele (0.44). The median level of ACE was found to be 65.96 ng/mL (48.12-86.24) which is towards lower side of the normal range. ACE levels were found to be increased among individual having either of the homozygotes that is II or DD and higher frequency of heterozygote (ID) is indicative of advantage in the population by maintaining lower ACE levels. The limitation of the present study is low sample size, however, the merit is that the subjects belonged to a Mendalian population with a common gene pool.

  14. Motion detection and correction for dynamic 15O-water myocardial perfusion PET studies

    International Nuclear Information System (INIS)

    Naum, Alexandru; Laaksonen, Marko S.; Oikonen, Vesa; Teraes, Mika; Jaervisalo, Mikko J.; Knuuti, Juhani; Tuunanen, Helena; Nuutila, Pirjo; Kemppainen, Jukka

    2005-01-01

    Patient motion during dynamic PET studies is a well-documented source of errors. The purpose of this study was to investigate the incidence of frame-to-frame motion in dynamic 15 O-water myocardial perfusion PET studies, to test the efficacy of motion correction methods and to study whether implementation of motion correction would have an impact on the perfusion results. We developed a motion detection procedure using external radioactive skin markers and frame-to-frame alignment. To evaluate motion, marker coordinates inside the field of view were determined in each frame for each study. The highest number of frames with identical spatial coordinates during the study were defined as ''non-moved''. Movement was considered present if even one marker changed position, by one pixel/frame compared with reference, in one axis, and such frames were defined as ''moved''. We tested manual, in-house-developed motion correction software and an automatic motion correction using a rigid body point model implemented in MIPAV (Medical Image Processing, Analysis and Visualisation) software. After motion correction, remaining motion was re-analysed. Myocardial blood flow (MBF) values were calculated for both non-corrected and motion-corrected datasets. At rest, patient motion was found in 18% of the frames, but during pharmacological stress the fraction increased to 45% and during physical exercise it rose to 80%. Both motion correction algorithms significantly decreased (p<0.006) the number of moved frames and the amplitude of motion (p<0.04). Motion correction significantly increased MBF results during bicycle exercise (p<0.02). At rest or during adenosine infusion, the motion correction had no significant effects on MBF values. Significant motion is a common phenomenon in dynamic cardiac studies during adenosine infusion but especially during exercise. Applying motion correction for the data acquired during exercise clearly changed the MBF results, indicating that motion

  15. A method for correcting the depth-of-interaction blurring in PET cameras

    International Nuclear Information System (INIS)

    Rogers, J.G.

    1993-11-01

    A method is presented for the purpose of correcting PET images for the blurring caused by variations in the depth-of-interaction in position-sensitive gamma ray detectors. In the case of a fine-cut 50x50x30 mm BGO block detector, the method is shown to improve the detector resolution by about 25%, measured in the geometry corresponding to detection at the edge of the field-of-view. Strengths and weaknesses of the method are discussed and its potential usefulness for improving the images of future PET cameras is assessed. (author). 8 refs., 3 figs

  16. Genetic variants of ACE (Insertion/Deletion) and AGT (M268T) genes in patients with diabetes and nephropathy.

    Science.gov (United States)

    Shaikh, Rozeena; Shahid, Syed M; Mansoor, Qaisar; Ismail, Muhammad; Azhar, Abid

    2014-06-01

    Diabetes mellitus (DM) has been a growing epidemic worldwide and poses a major socio-economic challenge. The leading cause of DM death is nephropathy due to end-stage renal disease (ESRD). This study aims to identify the possible association of I/D variants of the ACE gene and M268T (rs699) of the AGT gene of renin-angiotensin-aldosterone system (RAAS). Study subjects include 115 patients with DM, 110 with diabetic nephropathy (DN) and 110 controls. Fasting blood samples were collected for biochemical analyses and PCR amplification of specific regions of the ACE and AGT genes using primers. The distribution of ACE (I/D) II 28.8%, ID 35.6% and DD 35.6% while in DN II 24.5%, ID 41% and DD 34.5%. The AGT (M268T) genotypes were distributed in DM as TT 30.4%, MT 66.9% and MM 2.6% while in DN subjects TT 56.4%, MT 42.7% and MM 0.9%. Significant differences were observed in the DD genotype and D allele of the ACE gene and the TT genotype and T allele of AGT genes between diabetic patients with and without nephropathy. The study may conclude that the D allele polymorphism in the ACE gene and the T allele polymorphism in AGT gene may be considered as genetic risk factors for the development of nephropathy in diabetes. © The Author(s) 2014.

  17. Association of ACE and FACTOR VII gene variability with the risk of coronary heart disease in north Indian population.

    Science.gov (United States)

    Sobti, R C; Maithil, Nishi; Thakur, Hitender; Sharma, Yashpaul; Talwar, K K

    2010-08-01

    The angiotensin converting enzyme (ACE) is a key factor in the production of angiotensin II and in the degradation of bradykinin. Chronic exposure to high levels of circulating and tissue ACE predispose to vascular wall thickening and atherosclerosis. Factor VII (FACTOR VII) is the first enzyme in the extrinsic pathway of the blood coagulation system and plays a key role in hemostasis; it also contributes to the occurrence of thrombotic events. In this study, we have examined the association of ACE and FACTOR VII gene in coronary heart disease patients (n = 300) and their age-matched controls (n = 300). Genotyping was done by PCR-RFLP method. No significant difference was observed in the distribution of I/D genotypes of ACE between cases and controls. In case of FACTOR VII R353Q polymorphism, there was not much difference in the distribution of alleles. AA genotype had protective effect for CHD (OR 0.56, 95% CI 0.37-0.83, P = 0.001). In case of FACTOR VII VNTR, there was difference in the distribution of alleles, H6 (73.5) and H7 (25.5) in cases, and H6 (70.5) and H7 (30.5) in controls. H6H7 and H7H7 genotypes had a protective effect for CHD with OR 0.27, 95% CI 0.18-0.41, P FACTOR VII R353Q and H6H7 and H7H7 genotypes of FACTOR VII VNTR showed protective effect for CHD.

  18. Association of eNOS and ACE gene polymorphisms and plasma nitric oxide with risk of non-small cell lung cancer in South India.

    Science.gov (United States)

    Peddireddy, Vidyullatha; Badabagni, Siva Prasad; Gundimeda, Sandhya Devi; Mundluru, Hema Prasad

    2018-01-01

    The role of ACE and eNOS gene polymorphisms and their association with various cancers were reported. However, their role in the lung cancer is unclear. In this study, we analyzed eNOS and ACE gene polymorphisms and the risk of non-small cell lung cancer (NSCLC) in South Indian population. For the eNOS gene, the homozygous "AA" genotypic frequency was significantly associated with NSCLC with an overall risk of 3.6-fold (P = 0.006, odds ratio = 3.58, 95% confidence interval = 1.66, 7.723). The heterozygous "I/D" genotypic frequency of ACE gene was significantly higher in NSCLC patients when compared to the controls with a 2.29-fold risk for NSCLC. Multiple regression analyses indicated that gender, smoking status, and polymorphisms in eNOS and ACE genes as the strongest predicting factors for an increased susceptibility to NSCLC. We report for the first time that polymorphisms in the eNOS "A/A" (homozygous mutant) and ACE "I/D" genotypes might contribute to the increased risk of NSCLC in the South Indian population. © 2016 John Wiley & Sons Ltd.

  19. Towards Implementing an MR-based PET Attenuation Correction Method for Neurological Studies on the MR-PET Brain Prototype

    Science.gov (United States)

    Catana, Ciprian; van der Kouwe, Andre; Benner, Thomas; Michel, Christian J.; Hamm, Michael; Fenchel, Matthias; Fischl, Bruce; Rosen, Bruce; Schmand, Matthias; Sorensen, A. Gregory

    2013-01-01

    A number of factors have to be considered for implementing an accurate attenuation correction (AC) in a combined MR-PET scanner. In this work, some of these challenges were investigated and an AC method based entirely on the MR data obtained with a single dedicated sequence was developed and used for neurological studies performed with the MR-PET human brain scanner prototype. Methods The focus was on the bone/air segmentation problem, the bone linear attenuation coefficient selection and the RF coil positioning. The impact of these factors on the PET data quantification was studied in simulations and experimental measurements performed on the combined MR-PET scanner. A novel dual-echo ultra-short echo time (DUTE) MR sequence was proposed for head imaging. Simultaneous MR-PET data were acquired and the PET images reconstructed using the proposed MR-DUTE-based AC method were compared with the PET images reconstructed using a CT-based AC. Results Our data suggest that incorrectly accounting for the bone tissue attenuation can lead to large underestimations (>20%) of the radiotracer concentration in the cortex. Assigning a linear attenuation coefficient of 0.143 or 0.151 cm−1 to bone tissue appears to give the best trade-off between bias and variability in the resulting images. Not identifying the internal air cavities introduces large overestimations (>20%) in adjacent structures. Based on these results, the segmented CT AC method was established as the “silver standard” for the segmented MR-based AC method. Particular to an integrated MR-PET scanner, ignoring the RF coil attenuation can cause large underestimations (i.e. up to 50%) in the reconstructed images. Furthermore, the coil location in the PET field of view has to be accurately known. Good quality bone/air segmentation can be performed using the DUTE data. The PET images obtained using the MR-DUTE- and CT-based AC methods compare favorably in most of the brain structures. Conclusion An MR-DUTE-based AC

  20. Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype.

    Science.gov (United States)

    Catana, Ciprian; van der Kouwe, Andre; Benner, Thomas; Michel, Christian J; Hamm, Michael; Fenchel, Matthias; Fischl, Bruce; Rosen, Bruce; Schmand, Matthias; Sorensen, A Gregory

    2010-09-01

    Several factors have to be considered for implementing an accurate attenuation-correction (AC) method in a combined MR-PET scanner. In this work, some of these challenges were investigated, and an AC method based entirely on the MRI data obtained with a single dedicated sequence was developed and used for neurologic studies performed with the MR-PET human brain scanner prototype. The focus was on the problem of bone-air segmentation, selection of the linear attenuation coefficient for bone, and positioning of the radiofrequency coil. The impact of these factors on PET data quantification was studied in simulations and experimental measurements performed on the combined MR-PET scanner. A novel dual-echo ultrashort echo time (DUTE) MRI sequence was proposed for head imaging. Simultaneous MR-PET data were acquired, and the PET images reconstructed using the proposed DUTE MRI-based AC method were compared with the PET images that had been reconstructed using a CT-based AC method. Our data suggest that incorrectly accounting for the bone tissue attenuation can lead to large underestimations (>20%) of the radiotracer concentration in the cortex. Assigning a linear attenuation coefficient of 0.143 or 0.151 cm(-1) to bone tissue appears to give the best trade-off between bias and variability in the resulting images. Not identifying the internal air cavities introduces large overestimations (>20%) in adjacent structures. On the basis of these results, the segmented CT AC method was established as the silver standard for the segmented MRI-based AC method. For an integrated MR-PET scanner, in particular, ignoring the radiofrequency coil attenuation can cause large underestimations (i.e., PET field of view has to be accurately known. High-quality bone-air segmentation can be performed using the DUTE data. The PET images obtained using the DUTE MRI- and CT-based AC methods compare favorably in most of

  1. New component-based normalization method to correct PET system models

    International Nuclear Information System (INIS)

    Kinouchi, Shoko; Miyoshi, Yuji; Suga, Mikio; Yamaya, Taiga; Yoshida, Eiji; Nishikido, Fumihiko; Tashima, Hideaki

    2011-01-01

    Normalization correction is necessary to obtain high-quality reconstructed images in positron emission tomography (PET). There are two basic types of normalization methods: the direct method and component-based methods. The former method suffers from the problem that a huge count number in the blank scan data is required. Therefore, the latter methods have been proposed to obtain high statistical accuracy normalization coefficients with a small count number in the blank scan data. In iterative image reconstruction methods, on the other hand, the quality of the obtained reconstructed images depends on the system modeling accuracy. Therefore, the normalization weighing approach, in which normalization coefficients are directly applied to the system matrix instead of a sinogram, has been proposed. In this paper, we propose a new component-based normalization method to correct system model accuracy. In the proposed method, two components are defined and are calculated iteratively in such a way as to minimize errors of system modeling. To compare the proposed method and the direct method, we applied both methods to our small OpenPET prototype system. We achieved acceptable statistical accuracy of normalization coefficients while reducing the count number of the blank scan data to one-fortieth that required in the direct method. (author)

  2. Angiotensin-converting enzyme activity in Cavalier King Charles Spaniels with an ACE gene polymorphism and myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Meurs, Kathryn M.; Olsen, Lisbeth H.; Reimann, Maria J.

    2018-01-01

    a canine ACE gene polymorphism associated with a decrease in angiotensin-converting enzyme (ACE) activity. The aim of this study was to evaluate for the prevalence of the ACE polymorphism in CKCS with mitral valve disease and to determine whether the presence of the polymorphism is associated......Objectives Myxomatous mitral valve disease (MMVD) is the most common heart disease in the dog. It is particularly common in the Cavalier King Charles Spaniel (CKCS) breed and affected dogs are frequently managed with angiotensin-converting enzyme inhibitors (ACE-I). We have previously identified...... with alterations in ACE activity at different stages of cardiac disease. Methods Seventy-three dogs with a diagnosis of mitral valve disease were evaluated and a blood sample was drawn for ACE polymorphism genotyping and ACE activity measurement. Results Forty-three dogs were homozygous for the ACE polymorphism...

  3. Impact of respiratory motion correction and spatial resolution on lesion detection in PET: a simulation study based on real MR dynamic data

    Science.gov (United States)

    Polycarpou, Irene; Tsoumpas, Charalampos; King, Andrew P.; Marsden, Paul K.

    2014-02-01

    The aim of this study is to investigate the impact of respiratory motion correction and spatial resolution on lesion detectability in PET as a function of lesion size and tracer uptake. Real respiratory signals describing different breathing types are combined with a motion model formed from real dynamic MR data to simulate multiple dynamic PET datasets acquired from a continuously moving subject. Lung and liver lesions were simulated with diameters ranging from 6 to 12 mm and lesion to background ratio ranging from 3:1 to 6:1. Projection data for 6 and 3 mm PET scanner resolution were generated using analytic simulations and reconstructed without and with motion correction. Motion correction was achieved using motion compensated image reconstruction. The detectability performance was quantified by a receiver operating characteristic (ROC) analysis obtained using a channelized Hotelling observer and the area under the ROC curve (AUC) was calculated as the figure of merit. The results indicate that respiratory motion limits the detectability of lung and liver lesions, depending on the variation of the breathing cycle length and amplitude. Patients with large quiescent periods had a greater AUC than patients with regular breathing cycles and patients with long-term variability in respiratory cycle or higher motion amplitude. In addition, small (less than 10 mm diameter) or low contrast (3:1) lesions showed the greatest improvement in AUC as a result of applying motion correction. In particular, after applying motion correction the AUC is improved by up to 42% with current PET resolution (i.e. 6 mm) and up to 51% for higher PET resolution (i.e. 3 mm). Finally, the benefit of increasing the scanner resolution is small unless motion correction is applied. This investigation indicates high impact of respiratory motion correction on lesion detectability in PET and highlights the importance of motion correction in order to benefit from the increased resolution of future

  4. Impact of respiratory motion correction and spatial resolution on lesion detection in PET: a simulation study based on real MR dynamic data

    International Nuclear Information System (INIS)

    Polycarpou, Irene; Tsoumpas, Charalampos; King, Andrew P; Marsden, Paul K

    2014-01-01

    The aim of this study is to investigate the impact of respiratory motion correction and spatial resolution on lesion detectability in PET as a function of lesion size and tracer uptake. Real respiratory signals describing different breathing types are combined with a motion model formed from real dynamic MR data to simulate multiple dynamic PET datasets acquired from a continuously moving subject. Lung and liver lesions were simulated with diameters ranging from 6 to 12 mm and lesion to background ratio ranging from 3:1 to 6:1. Projection data for 6 and 3 mm PET scanner resolution were generated using analytic simulations and reconstructed without and with motion correction. Motion correction was achieved using motion compensated image reconstruction. The detectability performance was quantified by a receiver operating characteristic (ROC) analysis obtained using a channelized Hotelling observer and the area under the ROC curve (AUC) was calculated as the figure of merit. The results indicate that respiratory motion limits the detectability of lung and liver lesions, depending on the variation of the breathing cycle length and amplitude. Patients with large quiescent periods had a greater AUC than patients with regular breathing cycles and patients with long-term variability in respiratory cycle or higher motion amplitude. In addition, small (less than 10 mm diameter) or low contrast (3:1) lesions showed the greatest improvement in AUC as a result of applying motion correction. In particular, after applying motion correction the AUC is improved by up to 42% with current PET resolution (i.e. 6 mm) and up to 51% for higher PET resolution (i.e. 3 mm). Finally, the benefit of increasing the scanner resolution is small unless motion correction is applied. This investigation indicates high impact of respiratory motion correction on lesion detectability in PET and highlights the importance of motion correction in order to benefit from the increased resolution of future

  5. Angiotensin converting enzyme DD genotype is associated with acute coronary syndrome severity and sudden cardiac death in Taiwan: a case-control emergency room study.

    Science.gov (United States)

    Chen, Ying-Hsin; Liu, Jui-Ming; Hsu, Ren-Jun; Hu, Sheng-Chuan; Harn, Horng-Jyh; Chen, Shee-Ping; Jeng, Jing-Ren; Wu, Chieh-Lin; Ho, Jar-Yi; Yu, Cheng-Ping

    2012-02-15

    Angiotensin converting enzyme (ACE) gene insertion/deletion (I/D) polymorphisms have been associated with acute coronary syndrome (ACS); however, several controversial results have also been found in different studied populations. This hospital-based, emergency room, case-control study in Taiwan retrospectively investigated 111 ACS patients, and 195 non-coronary subjects as a control group, to study the effects of ACE I/D polymorphism in the most urgent ACS patients. ACE I/D polymorphisms were determined by polymerase chain reaction-based assays and their associations with ACS risk, severity, and sudden cardiac death were determined. The ACE DD genotype was associated with ACS incidence. The DD genotype was associated with a significant 4-fold higher risk of ACS in multivariate analysis (odds ratio (OR) = 4.295; 95% confidence interval (CI): 1.436-12.851, p = 0.009), and a 3.35-fold higher risk of acute myocardial infarction. DD genotype carriers also had more than 3-fold higher risks of stenosis in all the three coronary arteries, left anterior descending artery infarction, and anterior wall infarction. In addition, the DD genotype was also associated with a higher risk of sudden cardiac death (OR = 6.484, 95% CI: 1.036-40.598, p = 0.046). This study demonstrated that the ACE DD genotype is an independent risk factor for ACS, and in particular, for acute myocardial infarction. In addition, the ACE DD genotype is also associated with greater ACS severity and a higher risk of sudden cardiac death. ACE genotyping is recommended for patients with a history of ACS, and more intensive preventive care is suggested for patients with the DD genotype.

  6. Does angiotensin-converting enzyme-1 (ACE-1) gene polymorphism lead to chronic kidney disease among hypertensive patients?

    Science.gov (United States)

    Sarkar, Taposh; Singh, Narinder Pal; Kar, Premashish; Husain, Syed Akhtar; Kapoor, Seema; Pollipalli, Sunil Kumar; Kumar, Anish; Garg, Neena

    2016-06-01

    Hypertension is one of the important contributing factors linked with both causation and development of kidney disease. It is a multifactorial, polygenic, and complex disorder due to interaction of several risk genes with environmental factors. The present study was aimed to explore genetic polymorphism in ACE-1 gene as a risk factor for CKD among hypertensive patients. Three hundred patients were enrolled in the study. Ninety were hypertensive patients with CKD taken as cases, whereas 210 hypertensive patients without CKD were taken as controls. Demographic data including age, sex, Body mass index (BMI), and other risk factors were also recorded. DNA was extracted from blood by salting out method. Genotyping of ACE gene was done by PCR technique. All the statistical analysis was done by using Epi Info and SPSS version 16 software (SPSS Inc., Chicago, IL). Mean age was higher in the control group (p ACE gene (OR = 1.42, 95% CI = 0.72-2.81). Similarly, the risk for CKD among hypertensive patients was also associated with D allele of ACE gene (OR = 1.25, 95% CI = 0.86-1.79). It is concluded that ACE-DD genotype may be a risk factor for the causation and development of chronic kidney failure among hypertensive patients.

  7. Relationship between major depressive disorder and ACE gene I/D polymorphism in a Turkish population

    Directory of Open Access Journals (Sweden)

    Sema Inanir

    2016-04-01

    Full Text Available Abstract Background Major depressive disorder (MDD is a complex disease and a significant health problem that is prevalent across the world. Angiotensin-converting enzyme (ACE has an important role in renin-angiotensin system (RAS and converts inactive angiotensin I to a potent vasopressor and aldosterone-stimulating peptide angiotensin II. Levels of ACE in plasma vary according to the insertion/deletion (I/D polymorphism of ACE gene. Objective The aim of the current study was to examine the influence ACE gene I/D variations on the risk of MDD. Methods In the present case-control study, we analyzed ACE I/D polymorphism in 346 MDD patients and 210 healthy subjects using polymerase chain reaction technique. Results Comparing the two groups, no significant difference was observed with regard to either genotype distributions or allele frequencies of the I/D polymorphism of ACE gene. Discussion Our findings suggest that the ACE I/D polymorphism is not associated with MDD in Turkish case-control study. Further studies are still needed.

  8. Prevalence of angiotensin converting enzyme (ACE) gene insertion/deletion polymorphism in South Indian population with hypertension and chronic kidney disease.

    Science.gov (United States)

    Shanmuganathan, R; Kumaresan, R; Giri, P

    2015-01-01

    Chronic Kidney Disease (CKD) is associated with a high risk of developing further severe complications such as, cardiovascular disease and eventually End Stage Renal Disease (ESRD) leading to death. Hypertension plays a key role in the progression of renal failure and is also a chief risk factor for the occurrence of End Stage Renal Disease (ESRD). This study investigates the possible association of insertion (I) and deletion (D) polymorphism of ACE gene in patients of Chronic Kidney Disease (CKD) with and without hypertension (HT). Total 120 participants with 30 members in each group (Control, HT, CKD and CKD-HT) were chosen followed by informed consent. Blood samples were collected and subjected to biochemical analyses and nested PCR amplification was performed to genotype the DNA, for ACE I/D using specific primers. Statistical analyses were performed using SPSS version 13. Allele and genotypic frequency was calculated by direct gene counting method. Comparison of the different genotypes was done by using Chi square test. Odd's ratios were calculated with a 95% confidence interval limit. The ACE genotype were distributed as II, 27 (90%); DD, 2 (6.67%) and ID, 1 (3.33%) in control, II, 1 (3.33%); DD, 5 (16.67%) and ID, 24 (80%) in HT, II, 4 (13.33%); DD, 24 (80%) and ID, 2 (6.67%) in CKD and II, 0 (0%); DD, 2 (6.67%) and ID, 28 (93.33%) in CKD-HT group. D allele of ACE gene confers a greater role in genetic variations underlying CKD and hypertension. This result suggest that CKD patients should be offered analysis for defects in ACE I/D polymorphisms, especially if they are hypertensive.

  9. Assessment of the rs4340 ACE gene polymorphism in acute coronary syndrome in a Western Mexican population.

    Science.gov (United States)

    Valdez-Haro, A; Valle, Y; Valdes-Alvarado, E; Casillas-Muñoz, F; Muñoz-Valle, J F; Reynoso-Villalpando, G L; Flores-Salinas, H E; Padilla-Gutiérrez, J R

    2017-09-27

    Acute coronary syndrome (ACS) is considered one of the main causes of death worldwide. Contradictory findings concerning the impact of the angiotensin-converting enzyme (ACE) gene on cardiovascular diseases have been reported. Previous conclusions point out that the variability in results depends on ethnicity and genetic polymorphisms to determine the association of rs4340 polymorphisms of the ACE gene and ACE circulating levels in ACS. Genotyping of rs4340 polymorphisms was performed in a total of 600 individuals from Western Mexico divided into two groups: the ACS and the control group (CG). The polymorphisms were identified by polymerase chain reaction. Serum ACE concentration was determined by enzyme-linked immunosorbent assay. D/D carriers had higher ACE levels than I/I carriers (3.6 vs 2.8 ng/mL, P ACE concentration levels; however, the polymorphism was not associated with ACS.

  10. Angiotensin-Converting Enzyme (ACE) I/D and Alpha-Adducin (ADD1) G460W Gene Polymorphisms in Turkish Patients with Severe Chronic Tinnitus.

    Science.gov (United States)

    Yuce, Salim; Sancakdar, Enver; Bağcı, Gokhan; Koc, Sema; Kurtulgan, Hande Kucuk; Bağcı, Binnur; Doğan, Mansur; Uysal, İsmail Onder

    2016-04-01

    Tinnitus is described as a disturbing sound sensation in the absence of external stimulation. We aimed to investigate whether there is any relationship between severe chronic tinnitus and angiotensin-converting enzyme (ACE) I/D and α-adducin (ADD1) G460W gene polymorphisms. The patient group and control group consisted of 89 and 104 individuals, respectively. The evaluation of tinnitus was performed using the Strukturiertes Tinnitus-Interview (STI). The Tinnitus Handicap Inventory (THI) was used to evaluate the tinnitus severity. Polymerase chain reaction (PCR) and polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) techniques were used for genotyping. With regard to the ACE I/D polymorphism, there was no significant difference in genotype and allele frequencies between the patient group and control group. However, a statistically significant difference was found in genotype (pgene polymorphism. Combined genotype analysis showed that the ACE II /ADD1 GW genotype was statistically significantly higher in the patient group than in the control group (X2: 7.15, p=0.007). The odds ratio value of the GW genotype was 2.5 (95% CI=1.4-4.7) (pgene polymorphism and susceptibility to severe chronic tinnitus. It was found that the GW genotype increased the disease risk by 2.5-fold compared with other genotypes. This indicates that ADD1 G460W polymorphism could be an important factor in the pathophysiology of tinnitus.

  11. Influence of angiotensin converting enzyme (ACE) gene rs4362 polymorphism on the progression of kidney failure in patients with autosomal dominant polycystic kidney disease (ADPKD).

    Science.gov (United States)

    Ramanathan, Gnanasambandan; Ghosh, Santu; Elumalai, Ramprasad; Periyasamy, Soundararajan; Lakkakula, Bhaskar V K S

    2016-06-01

    Autosomal dominant polycystic kidney disease (ADPKD) is an inherited systemic disorder, characterized by the fluid filled cysts in the kidneys leading to end stage renal failure in later years of life. Hypertension is one of the major factors independently contributing to the chronic kidney disease (CKD) progression. The renin-angiotensin aldosterone system (RAAS) genes have been extensively studied as hypertension candidate genes. The aim of the present study was to investigate the role of angiotensin converting enzyme tagging - single nucleotide polymorphisms (ACE tag-SNPs) in progression of CKD in patients with ADPKD. m0 ethods: In the present study six ACE tagSNPs (angiotensin converting enzyme tag single nucleotide polymorphisms) and insertion/deletion (I/D) in 102 ADPKD patients and 106 control subjects were investigated. The tagSNPs were genotyped using FRET-based KASPar method and ACE ID by polymerase chain reaction (PCR) and electrophoresis. Genotypes and haplotypes were compared between ADPKD patients and controls. Univariate and multivariate logistic regression analyses were performed to assess the effect of genotypes and hypertension on CKD advancement. Mantel-Haenszel (M-H) stratified analysis was performed to study the relationship between different CKD stages and hypertension and their interaction. All loci were polymorphic and except rs4293 SNP the remaining loci followed Hardy-Weinberg equilibrium. Distribution of ACE genotypes and haplotypes in controls and ADPKD patients was not significant. A significant linkage disequilibrium (LD) was observed between SNPs forming two LD blocks. The univariate analysis revealed that the age, hypertension, family history of diabetes and ACE rs4362 contributed to the advancement of CKD. The results suggest that the ACE genotypes are effect modifiers of the relationship between hypertension and CKD advancement among the ADPKD patients.

  12. Clinical Evaluation of Zero-Echo-Time Attenuation Correction for Brain 18F-FDG PET/MRI: Comparison with Atlas Attenuation Correction.

    Science.gov (United States)

    Sekine, Tetsuro; Ter Voert, Edwin E G W; Warnock, Geoffrey; Buck, Alfred; Huellner, Martin; Veit-Haibach, Patrick; Delso, Gaspar

    2016-12-01

    Accurate attenuation correction (AC) on PET/MR is still challenging. The purpose of this study was to evaluate the clinical feasibility of AC based on fast zero-echo-time (ZTE) MRI by comparing it with the default atlas-based AC on a clinical PET/MR scanner. We recruited 10 patients with malignant diseases not located on the brain. In all patients, a clinically indicated whole-body 18 F-FDG PET/CT scan was acquired. In addition, a head PET/MR scan was obtained voluntarily. For each patient, 2 AC maps were generated from the MR images. One was atlas-AC, derived from T1-weighted liver acquisition with volume acceleration flex images (clinical standard). The other was ZTE-AC, derived from proton-density-weighted ZTE images by applying tissue segmentation and assigning continuous attenuation values to the bone. The AC map generated by PET/CT was used as a silver standard. On the basis of each AC map, PET images were reconstructed from identical raw data on the PET/MR scanner. All PET images were normalized to the SPM5 PET template. After that, these images were qualified visually and quantified in 67 volumes of interest (VOIs; automated anatomic labeling, atlas). Relative differences and absolute relative differences between PET images based on each AC were calculated. 18 F-FDG uptake in all 670 VOIs and generalized merged VOIs were compared using a paired t test. Qualitative analysis shows that ZTE-AC was robust to patient variability. Nevertheless, misclassification of air and bone in mastoid and nasal areas led to the overestimation of PET in the temporal lobe and cerebellum (%diff of ZTE-AC, 2.46% ± 1.19% and 3.31% ± 1.70%, respectively). The |%diff| of all 670 VOIs on ZTE was improved by approximately 25% compared with atlas-AC (ZTE-AC vs. atlas-AC, 1.77% ± 1.41% vs. 2.44% ± 1.63%, P PET in regions near the skull base. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  13. 3D Surface Realignment Tracking for Medical Imaging: A Phantom Study with PET Motion Correction

    DEFF Research Database (Denmark)

    Olesen, Oline Vinter; Paulsen, Rasmus Reinhold; Jensen, Rasmus Ramsbøl

    2011-01-01

    We present a complete system for motion correction in high resolution brain positron emission tomography (PET) imaging. It is based on a compact structured light scanner mounted above the patient tunnel of the Siemens High Resolution Research Tomograph PET brain scanner. The structured light system...... is equipped with a near infrared diode and uses phase-shift interferometry to compute 3D representations of the forehead of the patient. These 3D point clouds are progressively aligned to a reference surface and thereby giving the head pose changes. The estimated pose changes are used to reposition a sequence...... of recon- structed PET frames. To align the structured light system with the PET coordinate system a novel registration algorithm based on the PET trans- mission scan and an initial surface has been developed. The performance of the complete setup has been evaluated using a custom made phantom based...

  14. [Principles of PET].

    Science.gov (United States)

    Beuthien-Baumann, B

    2018-05-01

    Positron emission tomography (PET) is a procedure in nuclear medicine, which is applied predominantly in oncological diagnostics. In the form of modern hybrid machines, such as PET computed tomography (PET/CT) and PET magnetic resonance imaging (PET/MRI) it has found wide acceptance and availability. The PET procedure is more than just another imaging technique, but a functional method with the capability for quantification in addition to the distribution pattern of the radiopharmaceutical, the results of which are used for therapeutic decisions. A profound knowledge of the principles of PET including the correct indications, patient preparation, and possible artifacts is mandatory for the correct interpretation of PET results.

  15. Colorectal cancer staging: comparison of whole-body PET/CT and PET/MR.

    Science.gov (United States)

    Catalano, Onofrio A; Coutinho, Artur M; Sahani, Dushyant V; Vangel, Mark G; Gee, Michael S; Hahn, Peter F; Witzel, Thomas; Soricelli, Andrea; Salvatore, Marco; Catana, Ciprian; Mahmood, Umar; Rosen, Bruce R; Gervais, Debra

    2017-04-01

    Correct staging is imperative for colorectal cancer (CRC) since it influences both prognosis and management. Several imaging methods are used for this purpose, with variable performance. Positron emission tomography-magnetic resonance (PET/MR) is an innovative imaging technique recently employed for clinical application. The present study was undertaken to compare the staging accuracy of whole-body positron emission tomography-computed tomography (PET/CT) with whole-body PET/MR in patients with both newly diagnosed and treated colorectal cancer. Twenty-six patients, who underwent same day whole-body (WB) PET/CT and WB-PET/MR, were evaluated. PET/CT and PET/MR studies were interpreted by consensus by a radiologist and a nuclear medicine physician. Correlations with prior imaging and follow-up studies were used as the reference standard. Correct staging was compared between methods using McNemar's Chi square test. The two methods were in agreement and correct for 18/26 (69%) patients, and in agreement and incorrect for one patient (3.8%). PET/MR and PET/CT stages for the remaining 7/26 patients (27%) were discordant, with PET/MR staging being correct in all seven cases. PET/MR significantly outperformed PET/CT overall for accurate staging (P = 0.02). PET/MR outperformed PET/CT in CRC staging. PET/MR might allow accurate local and distant staging of CRC patients during both at the time of diagnosis and during follow-up.

  16. List-Mode PET Motion Correction Using Markerless Head Tracking: Proof-of-Concept With Scans of Human Subject

    DEFF Research Database (Denmark)

    Olesen, Oline Vinter; Sullivan, Jenna M.; Mulnix, Tim

    2013-01-01

    A custom designed markerless tracking system was demonstrated to be applicable for positron emission tomography (PET) brain imaging. Precise head motion registration is crucial for accurate motion correction (MC) in PET imaging. State-of-the-art tracking systems applied with PET brain imaging rely...... on markers attached to the patient's head. The marker attachment is the main weakness of these systems. A healthy volunteer participating in a cigarette smoking study to image dopamine release was scanned twice for 2 h with $^{11}{\\rm C}$-racolopride on the high resolution research tomograph (HRRT) PET...... in contrast recovery of small structures....

  17. Angiotensin-converting enzyme gene polymorphism in arrhythmogenic right ventricular dysplasia: is DD genotype helpful in predicting syncope risk?

    Science.gov (United States)

    Ozben, Beste; Altun, Ibrahim; Sabri Hancer, Veysel; Bilge, Ahmet Kaya; Tanrikulu, Azra Meryem; Diz-Kucukkaya, Reyhan; Fak, Ali Serdar; Yilmaz, Ercument; Adalet, Kamil

    2008-12-01

    Arrhythmogenic right ventricular dysplasia (ARVD) is a heritable disorder characterised by fibrofatty replacement of right ventricular myocytes and increased risk of ventricular arrhythmias and sudden cardiac death. Angiotensin-converting enzyme (ACE) gene insertion/deletion (I/D) polymorphism affects myocardial ACE levels. DD genotype favours myocardial fibrosis and is associated with malignant ventricular tachycardia. The aim of this study was to explore ACE gene polymorphism in ARVD patients. Twenty-nine patients with ARVD and 24 controls were included. All ARVD patients had documented sustained ventricular tachycardia. Thirteen patients had syncopal episodes. Six patients were resuscitated from sudden cardiac death. ACE gene polymorphism was identified by polymerase chain reaction technique. There was no significant difference in DD genotype frequency between ARVD patients and controls (44.8% vs. 45.8%, p=0.94). However, DD genotype frequency was significantly higher in ARVD patients with syncopal episodes compared to those without syncope (69.2% vs. 25.0%, p=0.017, odds ratio:6.750, 95% confidence interval: 1.318-34.565). DD genotype was detected in higher frequency also in patients with a family history of sudden cardiac death (66.7% vs. 39.1%,p=0.36). High prevalence of DD genotype in ARVD patients with syncope suggests that ACE I/D polymorphism might be useful in identifying high-risk patients for syncope.

  18. The effect of metal artefact reduction on CT-based attenuation correction for PET imaging in the vicinity of metallic hip implants. A phantom study

    International Nuclear Information System (INIS)

    Harnish, R.; Lang, T.F.; Prevrhal, S.; Alavi, A.; Zaidi, H.

    2014-01-01

    To determine if metal artefact reduction (MAR) combined with a priori knowledge of prosthesis material composition can be applied to obtain CT-based attenuation maps with sufficient accuracy for quantitative assessment of 18 F-fluorodeoxyglucose uptake in lesions near metallic prostheses. A custom hip prosthesis phantom with a lesion-sized cavity filled with 0.2 ml 18 F-FDG solution having an activity of 3.367 MBq adjacent to a prosthesis bore was imaged twice with a chrome-cobalt steel hip prosthesis and a plastic replica, respectively. Scanning was performed on a clinical hybrid PET/CT system equipped with an additional external 137 Cs transmission source. PET emission images were reconstructed from both phantom configurations with CT-based attenuation correction (CTAC) and with CT-based attenuation correction using MAR (MARCTAC). To compare results with the attenuation-correction method extant prior to the advent of PET/CT, we also carried out attenuation correction with 137 Cs transmission-based attenuation correction (TXAC). CTAC and MARCTAC images were scaled to attenuation coefficients at 511 keV using a trilinear function that mapped the highest CT values to the prosthesis alloy attenuation coefficient. Accuracy and spatial distribution of the lesion activity was compared between the three reconstruction schemes. Compared to the reference activity of 3.37 MBq, the estimated activity quantified from the PET image corrected by TXAC was 3.41 MBq. The activity estimated from PET images corrected by MARCTAC was similar in accuracy at 3.32 MBq. CTAC corrected PET images resulted in nearly 40% overestimation of lesion activity at 4.70 MBq. Comparison of PET images obtained with the plastic and metal prostheses in place showed that CTAC resulted in a marked distortion of the 18 F-FDG distribution within the lesion, whereas application of MARCTAC and TXAC resulted in lesion distributions similar to those observed with the plastic replica. (author)

  19. Angiotensin-converting enzyme genotype is not a significant genetic risk factor for idiopathic nephrotic syndrome in Croatian children.

    Science.gov (United States)

    Batinić, Danko; Sertić, Jadranka; Ćorić, Marijana; Konjevoda, Paško; Batinić, Danica; Milošević, Danko

    2015-01-01

    The association of the angiotensin-converting enzyme (ACE) gene insertion/deletion (I/D) polymorphism with idiopathic nephrotic syndrome (INS) is controversial. Only scarce information on European populations is available. The aim of the study was to investigate the distribution of the ACE gene I/D polymorphism and its impact on INS in children from Croatia. Ninety-five children with INS were investigated: 30 with minimal change disease (MCD), 35 with mesangial proliferative glomerulonephritis (MesPGN) and 30 with focal segmental glomerulosclerosis (FSGS). The control group consisted of 73 healthy adults. ACE gene was analyzed using the PCR method. The results were correlated with clinical features, renal morphology and response to immunosuppresive therapy. There was no correlation of ACE genotype with gender, age of the disease onset, level of proteinuria, presence of hematuria or hypertension, and GFR at onset of the disease. No statistically significant differences in ACE genotype or allele frequencies between the controls and whole group of patients, MCD group, MesPGN group, FSGS group, steroid sensitive (SS) patients, steroid resistant (SR) patients, as well as each other, were found, although DD genotype tended to be more frequent in FSGS patients, SR patients, and frequent relapsers. Among 11 children treated with cyclophosphamide the D allele was significantly higher among non-responders (p = 0.003). DD genotype is not a genetic risk factor for acquiring INS nor significant phenotype modifier regarding to clinical and pathohistological picture and response to steroids in Croatian children. The potential application of ACE genotyping in predicting cyclophosphamide response deserves further investigation. © 2015 S. Karger AG, Basel.

  20. Attenuation correction for hybrid MR/PET scanners: a comparison study

    Energy Technology Data Exchange (ETDEWEB)

    Rota Kops, Elena [Forschungszentrum Jülich GmbH, Jülich (Germany); Ribeiro, Andre Santos [Imperial College London, London (United Kingdom); Caldeira, Liliana [Forschungszentrum Jülich GmbH, Jülich (Germany); Hautzel, Hubertus [Heinrich-Heine-University Düsseldorf, Düsseldorf (Germany); Lukas, Mathias [Technische Universitaet Muenchen, Munich (Germany); Antoch, Gerald [Heinrich-Heine-University Düsseldorf, Düsseldorf (Germany); Lerche, Christoph; Shah, Jon [Forschungszentrum Jülich GmbH, Jülich (Germany)

    2015-05-18

    Attenuation correction of PET data acquired in hybrid MR/PET scanners is still a challenge. Different methods have been adopted by several groups to obtain reliable attenuation maps (mu-maps). In this study we compare three methods: MGH, UCL, Neural-Network. The MGH method is based on an MR/CT template obtained with the SPM8 software. The UCL method uses a database of MR/CT pairs. Both generate mu-maps from MP-RAGE images. The feed-forward neural-network from Juelich (NN-Juelich) requires two UTE images; it generates segmented mu-maps. Data from eight subjects (S1-S8) measured in the Siemens 3T MR-BrainPET scanner were used. Corresponding CT images were acquired. The resulting mu-maps were compared against the CT-based mu-maps for each subject and method. Overlapped voxels and Dice similarity coefficients, D, for bone, soft-tissue and air regions, and relative differences images were calculated. The true positive (TP) recognized voxels for the whole head were 79.9% (NN-Juelich, S7) to 92.1% (UCL method, S1). D values of the bone were D=0.65 (NN-Juelich, S1) to D=0.87 (UCL method, S1). For S8 the MHG method failed (TP=76.4%; D=0.46 for bone). D values shared a common tendency in all subjects and methods to recognize soft-tissue as bone. The relative difference images showed a variation of -10.9% - +10.1%; for S8 and MHG method the values were -24.5% and +14.2%. A preliminary comparison of three methods for generation of mu-maps for MR/PET scanners is presented. The continuous methods (MGH, UCL) seem to generate reliable mu-maps, whilst the binary method seems to need further improvement. Future work will include more subjects, the reconstruction of corresponding PET data and their comparison.

  1. Attenuation correction for hybrid MR/PET scanners: a comparison study

    International Nuclear Information System (INIS)

    Rota Kops, Elena; Ribeiro, Andre Santos; Caldeira, Liliana; Hautzel, Hubertus; Lukas, Mathias; Antoch, Gerald; Lerche, Christoph; Shah, Jon

    2015-01-01

    Attenuation correction of PET data acquired in hybrid MR/PET scanners is still a challenge. Different methods have been adopted by several groups to obtain reliable attenuation maps (mu-maps). In this study we compare three methods: MGH, UCL, Neural-Network. The MGH method is based on an MR/CT template obtained with the SPM8 software. The UCL method uses a database of MR/CT pairs. Both generate mu-maps from MP-RAGE images. The feed-forward neural-network from Juelich (NN-Juelich) requires two UTE images; it generates segmented mu-maps. Data from eight subjects (S1-S8) measured in the Siemens 3T MR-BrainPET scanner were used. Corresponding CT images were acquired. The resulting mu-maps were compared against the CT-based mu-maps for each subject and method. Overlapped voxels and Dice similarity coefficients, D, for bone, soft-tissue and air regions, and relative differences images were calculated. The true positive (TP) recognized voxels for the whole head were 79.9% (NN-Juelich, S7) to 92.1% (UCL method, S1). D values of the bone were D=0.65 (NN-Juelich, S1) to D=0.87 (UCL method, S1). For S8 the MHG method failed (TP=76.4%; D=0.46 for bone). D values shared a common tendency in all subjects and methods to recognize soft-tissue as bone. The relative difference images showed a variation of -10.9% - +10.1%; for S8 and MHG method the values were -24.5% and +14.2%. A preliminary comparison of three methods for generation of mu-maps for MR/PET scanners is presented. The continuous methods (MGH, UCL) seem to generate reliable mu-maps, whilst the binary method seems to need further improvement. Future work will include more subjects, the reconstruction of corresponding PET data and their comparison.

  2. Motion correction of PET brain images through deconvolution: II. Practical implementation and algorithm optimization

    Science.gov (United States)

    Raghunath, N.; Faber, T. L.; Suryanarayanan, S.; Votaw, J. R.

    2009-02-01

    Image quality is significantly degraded even by small amounts of patient motion in very high-resolution PET scanners. When patient motion is known, deconvolution methods can be used to correct the reconstructed image and reduce motion blur. This paper describes the implementation and optimization of an iterative deconvolution method that uses an ordered subset approach to make it practical and clinically viable. We performed ten separate FDG PET scans using the Hoffman brain phantom and simultaneously measured its motion using the Polaris Vicra tracking system (Northern Digital Inc., Ontario, Canada). The feasibility and effectiveness of the technique was studied by performing scans with different motion and deconvolution parameters. Deconvolution resulted in visually better images and significant improvement as quantified by the Universal Quality Index (UQI) and contrast measures. Finally, the technique was applied to human studies to demonstrate marked improvement. Thus, the deconvolution technique presented here appears promising as a valid alternative to existing motion correction methods for PET. It has the potential for deblurring an image from any modality if the causative motion is known and its effect can be represented in a system matrix.

  3. Motion correction of PET brain images through deconvolution: II. Practical implementation and algorithm optimization

    International Nuclear Information System (INIS)

    Raghunath, N; Faber, T L; Suryanarayanan, S; Votaw, J R

    2009-01-01

    Image quality is significantly degraded even by small amounts of patient motion in very high-resolution PET scanners. When patient motion is known, deconvolution methods can be used to correct the reconstructed image and reduce motion blur. This paper describes the implementation and optimization of an iterative deconvolution method that uses an ordered subset approach to make it practical and clinically viable. We performed ten separate FDG PET scans using the Hoffman brain phantom and simultaneously measured its motion using the Polaris Vicra tracking system (Northern Digital Inc., Ontario, Canada). The feasibility and effectiveness of the technique was studied by performing scans with different motion and deconvolution parameters. Deconvolution resulted in visually better images and significant improvement as quantified by the Universal Quality Index (UQI) and contrast measures. Finally, the technique was applied to human studies to demonstrate marked improvement. Thus, the deconvolution technique presented here appears promising as a valid alternative to existing motion correction methods for PET. It has the potential for deblurring an image from any modality if the causative motion is known and its effect can be represented in a system matrix.

  4. Motion correction of PET brain images through deconvolution: II. Practical implementation and algorithm optimization

    Energy Technology Data Exchange (ETDEWEB)

    Raghunath, N; Faber, T L; Suryanarayanan, S; Votaw, J R [Department of Radiology, Emory University Hospital, 1364 Clifton Road, N.E. Atlanta, GA 30322 (United States)], E-mail: John.Votaw@Emory.edu

    2009-02-07

    Image quality is significantly degraded even by small amounts of patient motion in very high-resolution PET scanners. When patient motion is known, deconvolution methods can be used to correct the reconstructed image and reduce motion blur. This paper describes the implementation and optimization of an iterative deconvolution method that uses an ordered subset approach to make it practical and clinically viable. We performed ten separate FDG PET scans using the Hoffman brain phantom and simultaneously measured its motion using the Polaris Vicra tracking system (Northern Digital Inc., Ontario, Canada). The feasibility and effectiveness of the technique was studied by performing scans with different motion and deconvolution parameters. Deconvolution resulted in visually better images and significant improvement as quantified by the Universal Quality Index (UQI) and contrast measures. Finally, the technique was applied to human studies to demonstrate marked improvement. Thus, the deconvolution technique presented here appears promising as a valid alternative to existing motion correction methods for PET. It has the potential for deblurring an image from any modality if the causative motion is known and its effect can be represented in a system matrix.

  5. SU-C-9A-06: The Impact of CT Image Used for Attenuation Correction in 4D-PET

    International Nuclear Information System (INIS)

    Cui, Y; Bowsher, J; Yan, S; Cai, J; Das, S; Yin, F

    2014-01-01

    Purpose: To evaluate the appropriateness of using 3D non-gated CT image for attenuation correction (AC) in a 4D-PET (gated PET) imaging protocol used in radiotherapy treatment planning simulation. Methods: The 4D-PET imaging protocol in a Siemens PET/CT simulator (Biograph mCT, Siemens Medical Solutions, Hoffman Estates, IL) was evaluated. CIRS Dynamic Thorax Phantom (CIRS Inc., Norfolk, VA) with a moving glass sphere (8 mL) in the middle of its thorax portion was used in the experiments. The glass was filled with 18 F-FDG and was in a longitudinal motion derived from a real patient breathing pattern. Varian RPM system (Varian Medical Systems, Palo Alto, CA) was used for respiratory gating. Both phase-gating and amplitude-gating methods were tested. The clinical imaging protocol was modified to use three different CT images for AC in 4D-PET reconstruction: first is to use a single-phase CT image to mimic actual clinical protocol (single-CT-PET); second is to use the average intensity projection CT (AveIP-CT) derived from 4D-CT scanning (AveIP-CT-PET); third is to use 4D-CT image to do the phase-matched AC (phase-matching- PET). Maximum SUV (SUVmax) and volume of the moving target (glass sphere) with threshold of 40% SUVmax were calculated for comparison between 4D-PET images derived with different AC methods. Results: The SUVmax varied 7.3%±6.9% over the breathing cycle in single-CT-PET, compared to 2.5%±2.8% in AveIP-CT-PET and 1.3%±1.2% in phasematching PET. The SUVmax in single-CT-PET differed by up to 15% from those in phase-matching-PET. The target volumes measured from single- CT-PET images also presented variations up to 10% among different phases of 4D PET in both phase-gating and amplitude-gating experiments. Conclusion: Attenuation correction using non-gated CT in 4D-PET imaging is not optimal process for quantitative analysis. Clinical 4D-PET imaging protocols should consider phase-matched 4D-CT image if available to achieve better accuracy

  6. SU-C-9A-06: The Impact of CT Image Used for Attenuation Correction in 4D-PET

    Energy Technology Data Exchange (ETDEWEB)

    Cui, Y; Bowsher, J; Yan, S; Cai, J; Das, S; Yin, F [Duke University Medical Center, Durham, NC (United States)

    2014-06-01

    Purpose: To evaluate the appropriateness of using 3D non-gated CT image for attenuation correction (AC) in a 4D-PET (gated PET) imaging protocol used in radiotherapy treatment planning simulation. Methods: The 4D-PET imaging protocol in a Siemens PET/CT simulator (Biograph mCT, Siemens Medical Solutions, Hoffman Estates, IL) was evaluated. CIRS Dynamic Thorax Phantom (CIRS Inc., Norfolk, VA) with a moving glass sphere (8 mL) in the middle of its thorax portion was used in the experiments. The glass was filled with {sup 18}F-FDG and was in a longitudinal motion derived from a real patient breathing pattern. Varian RPM system (Varian Medical Systems, Palo Alto, CA) was used for respiratory gating. Both phase-gating and amplitude-gating methods were tested. The clinical imaging protocol was modified to use three different CT images for AC in 4D-PET reconstruction: first is to use a single-phase CT image to mimic actual clinical protocol (single-CT-PET); second is to use the average intensity projection CT (AveIP-CT) derived from 4D-CT scanning (AveIP-CT-PET); third is to use 4D-CT image to do the phase-matched AC (phase-matching- PET). Maximum SUV (SUVmax) and volume of the moving target (glass sphere) with threshold of 40% SUVmax were calculated for comparison between 4D-PET images derived with different AC methods. Results: The SUVmax varied 7.3%±6.9% over the breathing cycle in single-CT-PET, compared to 2.5%±2.8% in AveIP-CT-PET and 1.3%±1.2% in phasematching PET. The SUVmax in single-CT-PET differed by up to 15% from those in phase-matching-PET. The target volumes measured from single- CT-PET images also presented variations up to 10% among different phases of 4D PET in both phase-gating and amplitude-gating experiments. Conclusion: Attenuation correction using non-gated CT in 4D-PET imaging is not optimal process for quantitative analysis. Clinical 4D-PET imaging protocols should consider phase-matched 4D-CT image if available to achieve better accuracy.

  7. One registration multi-atlas-based pseudo-CT generation for attenuation correction in PET/MRI

    International Nuclear Information System (INIS)

    Arabi, Hossein; Zaidi, Habib

    2016-01-01

    The outcome of a detailed assessment of various strategies for atlas-based whole-body bone segmentation from magnetic resonance imaging (MRI) was exploited to select the optimal parameters and setting, with the aim of proposing a novel one-registration multi-atlas (ORMA) pseudo-CT generation approach. The proposed approach consists of only one online registration between the target and reference images, regardless of the number of atlas images (N), while for the remaining atlas images, the pre-computed transformation matrices to the reference image are used to align them to the target image. The performance characteristics of the proposed method were evaluated and compared with conventional atlas-based attenuation map generation strategies (direct registration of the entire atlas images followed by voxel-wise weighting (VWW) and arithmetic averaging atlas fusion). To this end, four different positron emission tomography (PET) attenuation maps were generated via arithmetic averaging and VWW scheme using both direct registration and ORMA approaches as well as the 3-class attenuation map obtained from the Philips Ingenuity TF PET/MRI scanner commonly used in the clinical setting. The evaluation was performed based on the accuracy of extracted whole-body bones by the different attenuation maps and by quantitative analysis of resulting PET images compared to CT-based attenuation-corrected PET images serving as reference. The comparison of validation metrics regarding the accuracy of extracted bone using the different techniques demonstrated the superiority of the VWW atlas fusion algorithm achieving a Dice similarity measure of 0.82 ± 0.04 compared to arithmetic averaging atlas fusion (0.60 ± 0.02), which uses conventional direct registration. Application of the ORMA approach modestly compromised the accuracy, yielding a Dice similarity measure of 0.76 ± 0.05 for ORMA-VWW and 0.55 ± 0.03 for ORMA-averaging. The results of quantitative PET analysis followed the same

  8. One registration multi-atlas-based pseudo-CT generation for attenuation correction in PET/MRI

    Energy Technology Data Exchange (ETDEWEB)

    Arabi, Hossein [Geneva University Hospital, Division of Nuclear Medicine and Molecular Imaging, Geneva 4 (Switzerland); Zaidi, Habib [Geneva University Hospital, Division of Nuclear Medicine and Molecular Imaging, Geneva 4 (Switzerland); Geneva University, Geneva Neuroscience Center, Geneva (Switzerland); University of Groningen, University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University of Southern Denmark, Department of Nuclear Medicine, Odense (Denmark)

    2016-10-15

    The outcome of a detailed assessment of various strategies for atlas-based whole-body bone segmentation from magnetic resonance imaging (MRI) was exploited to select the optimal parameters and setting, with the aim of proposing a novel one-registration multi-atlas (ORMA) pseudo-CT generation approach. The proposed approach consists of only one online registration between the target and reference images, regardless of the number of atlas images (N), while for the remaining atlas images, the pre-computed transformation matrices to the reference image are used to align them to the target image. The performance characteristics of the proposed method were evaluated and compared with conventional atlas-based attenuation map generation strategies (direct registration of the entire atlas images followed by voxel-wise weighting (VWW) and arithmetic averaging atlas fusion). To this end, four different positron emission tomography (PET) attenuation maps were generated via arithmetic averaging and VWW scheme using both direct registration and ORMA approaches as well as the 3-class attenuation map obtained from the Philips Ingenuity TF PET/MRI scanner commonly used in the clinical setting. The evaluation was performed based on the accuracy of extracted whole-body bones by the different attenuation maps and by quantitative analysis of resulting PET images compared to CT-based attenuation-corrected PET images serving as reference. The comparison of validation metrics regarding the accuracy of extracted bone using the different techniques demonstrated the superiority of the VWW atlas fusion algorithm achieving a Dice similarity measure of 0.82 ± 0.04 compared to arithmetic averaging atlas fusion (0.60 ± 0.02), which uses conventional direct registration. Application of the ORMA approach modestly compromised the accuracy, yielding a Dice similarity measure of 0.76 ± 0.05 for ORMA-VWW and 0.55 ± 0.03 for ORMA-averaging. The results of quantitative PET analysis followed the same

  9. The effect of metal artefact reduction on CT-based attenuation correction for PET imaging in the vicinity of metallic hip implants: a phantom study.

    Science.gov (United States)

    Harnish, Roy; Prevrhal, Sven; Alavi, Abass; Zaidi, Habib; Lang, Thomas F

    2014-07-01

    To determine if metal artefact reduction (MAR) combined with a priori knowledge of prosthesis material composition can be applied to obtain CT-based attenuation maps with sufficient accuracy for quantitative assessment of (18)F-fluorodeoxyglucose uptake in lesions near metallic prostheses. A custom hip prosthesis phantom with a lesion-sized cavity filled with 0.2 ml (18)F-FDG solution having an activity of 3.367 MBq adjacent to a prosthesis bore was imaged twice with a chrome-cobalt steel hip prosthesis and a plastic replica, respectively. Scanning was performed on a clinical hybrid PET/CT system equipped with an additional external (137)Cs transmission source. PET emission images were reconstructed from both phantom configurations with CT-based attenuation correction (CTAC) and with CT-based attenuation correction using MAR (MARCTAC). To compare results with the attenuation-correction method extant prior to the advent of PET/CT, we also carried out attenuation correction with (137)Cs transmission-based attenuation correction (TXAC). CTAC and MARCTAC images were scaled to attenuation coefficients at 511 keV using a trilinear function that mapped the highest CT values to the prosthesis alloy attenuation coefficient. Accuracy and spatial distribution of the lesion activity was compared between the three reconstruction schemes. Compared to the reference activity of 3.37 MBq, the estimated activity quantified from the PET image corrected by TXAC was 3.41 MBq. The activity estimated from PET images corrected by MARCTAC was similar in accuracy at 3.32 MBq. CTAC corrected PET images resulted in nearly 40 % overestimation of lesion activity at 4.70 MBq. Comparison of PET images obtained with the plastic and metal prostheses in place showed that CTAC resulted in a marked distortion of the (18)F-FDG distribution within the lesion, whereas application of MARCTAC and TXAC resulted in lesion distributions similar to those observed with the plastic replica. MAR combined

  10. DD genotype of angiotensin-converting enzyme in type 2 diabetes mellitus with renal disease in Mexican Mestizos.

    Science.gov (United States)

    Palomo-Piñón, Silvia; Gutiérrez-Rodríguez, Margarita E; Díaz-Flores, Margarita; Sánchez-Barrera, Reyna; Valladares-Salgado, Adán; Utrera-Barillas, Dolores; Durán-Reyes, Genoveva; Galván-Duarte, Rosa E; Trinidad-Ramos, Pedro; Cruz, Miguel

    2009-04-01

    The DD genotype of angiotensin-converting enzyme (ACE) has been suggested as a major contributor of diabetic nephropathy in several populations. The purpose of the present study was to determine whether micro/macroalbuminuria is associated with ACE insertion/deletion (I/D) polymorphism in Mexican Mestizos with type 2 diabetes mellitus. A total of 435 patients with type 2 diabetes mellitus, of whom 233 had albuminuria, were characterized for the ACE I/D polymorphism by the polymerase chain reaction method. Clinical and biochemical characteristics and frequencies according to DD, ID and II genotypes in patients with and without albuminuria showed no significant differences. However, only females with micro/macroalbuminuria showed higher frequency of a DD genotype than those without albuminuria (27.9%, 21.2% and 10.5%, respectively; P DD genotype is a risk factor for the development of renal disease in Mexican Mestizo females with type 2 diabetes, indicating a possible DD genotype-associated sex effect in renal disease.

  11. ACE Gene I/D Polymorphism and Obesity in 1,574 Patients with Type 2 Diabetes Mellitus.

    Science.gov (United States)

    Pan, Yan-Hong; Wang, Min; Huang, Yan-Mei; Wang, Ying-Hui; Chen, Yin-Ling; Geng, Li-Jun; Zhang, Xiao-Xi; Zhao, Hai-Lu

    2016-01-01

    Association between ACE gene I/D polymorphism and the risk of overweight/obesity remains controversial. We investigated the possible relationship between ACE gene I/D polymorphism and obesity in Chinese type 2 diabetes mellitus (T2DM) patients. In this study, obesity was defined as a body mass index (BMI) value ≥ 25 kg/m 2 and subjects were classified into 4 groups (lean, normal, overweight, and obese). PCR (polymerase chain reaction) was used to detect the ACE gene I/D polymorphism in T2DM patients. Metabolic measurements including blood glucose, lipid profile, and blood pressure were obtained. Frequencies of the ACE genotypes (DD, ID, and II) were not significant among the 4 groups of BMI-defined patients ( P = 0.679) while ACE II carriers showed higher systolic blood pressure (SBP) and pulse pressure (PP) (all P ACE gene I/D polymorphism with obesity is insignificant in Chinese patients with T2DM. SBP and PP might be higher in the ACE II carriers than in the DD and ID carriers.

  12. Prevalence of angiotensin converting enzyme (ACE gene insertion/deletion polymorphism in South Indian population with hypertension and chronic kidney disease

    Directory of Open Access Journals (Sweden)

    R Shanmuganathan

    2015-01-01

    Full Text Available Context: Chronic Kidney Disease (CKD is associated with a high risk of developing further severe complications such as, cardiovascular disease and eventually End Stage Renal Disease (ESRD leading to death. Hypertension plays a key role in the progression of renal failure and is also a chief risk factor for the occurrence of End Stage Renal Disease (ESRD. Aim: This study investigates the possible association of insertion (I and deletion (D polymorphism of ACE gene in patients of Chronic Kidney Disease (CKD with and without hypertension (HT. Settings and Design: Total 120 participants with 30 members in each group (Control, HT, CKD and CKD-HT were chosen followed by informed consent. Materials and Methods: Blood samples were collected and subjected to biochemical analyses and nested PCR amplification was performed to genotype the DNA, for ACE I/D using specific primers. Statistical Analysis: Statistical analyses were performed using SPSS version 13. Allele and genotypic frequency was calculated by direct gene counting method. Comparison of the different genotypes was done by using Chi square test. Odd′s ratios were calculated with a 95% confidence interval limit. Results: The ACE genotype were distributed as II, 27 (90%; DD, 2 (6.67% and ID, 1 (3.33% in control, II, 1 (3.33%; DD, 5 (16.67% and ID, 24 (80% in HT, II, 4 (13.33%; DD, 24 (80% and ID, 2 (6.67% in CKD and II, 0 (0%; DD, 2 (6.67% and ID, 28 (93.33% in CKD-HT group. Conclusions: D allele of ACE gene confers a greater role in genetic variations underlying CKD and hypertension. This result suggest that CKD patients should be offered analysis for defects in ACE I/D polymorphisms, especially if they are hypertensive.

  13. Respiratory motion correction for PET oncology applications using affine transformation of list mode data

    International Nuclear Information System (INIS)

    Lamare, F; Cresson, T; Savean, J; Rest, C Cheze Le; Reader, A J; Visvikis, D

    2007-01-01

    Respiratory motion is a source of artefacts and reduced image quality in PET. Proposed methodology for correction of respiratory effects involves the use of gated frames, which are however of low signal-to-noise ratio. Therefore a method accounting for respiratory motion effects without affecting the statistical quality of the reconstructed images is necessary. We have implemented an affine transformation of list mode data for the correction of respiratory motion over the thorax. The study was performed using datasets of the NCAT phantom at different points throughout the respiratory cycle. List mode data based PET simulated frames were produced by combining the NCAT datasets with a Monte Carlo simulation. Transformation parameters accounting for respiratory motion were estimated according to an affine registration and were subsequently applied on the original list mode data. The corrected and uncorrected list mode datasets were subsequently reconstructed using the one-pass list mode EM (OPL-EM) algorithm. Comparison of corrected and uncorrected respiratory motion average frames suggests that an affine transformation in the list mode data prior to reconstruction can produce significant improvements in accounting for respiratory motion artefacts in the lungs and heart. However, the application of a common set of transformation parameters across the imaging field of view does not significantly correct the respiratory effects on organs such as the stomach, liver or spleen

  14. Deep Learning MR Imaging-based Attenuation Correction for PET/MR Imaging.

    Science.gov (United States)

    Liu, Fang; Jang, Hyungseok; Kijowski, Richard; Bradshaw, Tyler; McMillan, Alan B

    2018-02-01

    Purpose To develop and evaluate the feasibility of deep learning approaches for magnetic resonance (MR) imaging-based attenuation correction (AC) (termed deep MRAC) in brain positron emission tomography (PET)/MR imaging. Materials and Methods A PET/MR imaging AC pipeline was built by using a deep learning approach to generate pseudo computed tomographic (CT) scans from MR images. A deep convolutional auto-encoder network was trained to identify air, bone, and soft tissue in volumetric head MR images coregistered to CT data for training. A set of 30 retrospective three-dimensional T1-weighted head images was used to train the model, which was then evaluated in 10 patients by comparing the generated pseudo CT scan to an acquired CT scan. A prospective study was carried out for utilizing simultaneous PET/MR imaging for five subjects by using the proposed approach. Analysis of covariance and paired-sample t tests were used for statistical analysis to compare PET reconstruction error with deep MRAC and two existing MR imaging-based AC approaches with CT-based AC. Results Deep MRAC provides an accurate pseudo CT scan with a mean Dice coefficient of 0.971 ± 0.005 for air, 0.936 ± 0.011 for soft tissue, and 0.803 ± 0.021 for bone. Furthermore, deep MRAC provides good PET results, with average errors of less than 1% in most brain regions. Significantly lower PET reconstruction errors were realized with deep MRAC (-0.7% ± 1.1) compared with Dixon-based soft-tissue and air segmentation (-5.8% ± 3.1) and anatomic CT-based template registration (-4.8% ± 2.2). Conclusion The authors developed an automated approach that allows generation of discrete-valued pseudo CT scans (soft tissue, bone, and air) from a single high-spatial-resolution diagnostic-quality three-dimensional MR image and evaluated it in brain PET/MR imaging. This deep learning approach for MR imaging-based AC provided reduced PET reconstruction error relative to a CT-based standard within the brain compared

  15. Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests.

    Science.gov (United States)

    Demir, Mustafa; Toklu, Türkay; Abuqbeitah, Mohammad; Çetin, Hüseyin; Sezgin, H Sezer; Yeyin, Nami; Sönmezoğlu, Kerim

    2018-02-01

    The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General Electric GE company; SIGNATM model PET/MR and GE Discovery 710 model PET/CT. The main investigated aspects were spatial resolution, sensitivity, scatter fraction, count rate performance, image quality, count loss and random events correction accuracy. The findings of this study demonstrated superior sensitivity (~ 4 folds) of PET scanner in PET/MR compared to PET/CT system. Image quality test exhibited higher contrast in PET/MR (~ 9%) compared with PET/CT. The scatter fraction of PET/MR was 43.4% at noise equivalent count rate (NECR) peak of 218 kcps and the corresponding activity concentration was 17.7 kBq/cc. Whereas the scatter fraction of PET/CT was found as 39.2% at NECR peak of 72 kcps and activity concentration of 24.3 kBq/cc. The percentage error of the random event correction accuracy was 3.4% and 3.1% in PET/MR and PET/CT, respectively. It was concluded that PET/MR system is about 4 times more sensitive than PET/CT, and the contrast of hot lesions in PET/MR was ~ 9% higher than PET/CT. These outcomes also emphasize the possibility to achieve excellent clinical PET images with low administered dose and/or a short acquisition time in PET/MR.

  16. Angiotensin converting enzyme (ACE) gene expression in experimentally induced liver cirrhosis in rats.

    Science.gov (United States)

    Shahid, Syed Muhammad; Fatima, Syeda Nuzhat; Mahboob, Tabassum

    2013-09-01

    Angiotensin converting enzyme (ACE) is a key player of Renin Angiotensin System (RAS), involved in conversion of active product, angiotensin-II. Alterations in RAS have been implicated in the pathophysiology of various diseases involving heart, kidney, lung and liver. This study is designed to investigate the association of ACE gene expression in induction of liver cirrhosis in rats. Total 12 male albino Wistar rats were selected and divided in two groups. Control group received 0.9% NaCl, where as Test group received thioacidamide (TAA), dissolved in 0.9%NaCl, injected intraperitoneally at a dosage of 200mg/Kg of body weight, twice a week for 12 weeks. The rats were decapitated and blood sample was collected at the end of experimental period and used for liver functions, enzyme activity, antioxidant enzymes and lipid peroxidation estimations. Genomic DNA was isolated from excised tissue determine the ACE genotypes using specific primers. The ACE gene expression in liver tissue was assessed using the quantitative RT-PCR method. The activity of ALT, total and direct bilirubin, SOD and CAT levels were significantly high (pACE gene expression after 12 weeks TAA treatment in cirrhotic rats was significantly increased (pACE gene expression. The finding of major up-regulation of ACE in the experimental rat liver provides further insight into the complexities of the RAS and its regulation in liver injury. The development of specific modulators of ACE activity and function, in future, will help determine the role of ACE and its genetic variants in the pathophysiology of liver disease.

  17. The ACE gene D/I polymorphism as a modulator of severity of cystic fibrosis

    Directory of Open Access Journals (Sweden)

    Marson Fernando A L

    2012-08-01

    Full Text Available Abstract Background Cystic Fibrosis (CF is a monogenic disease with complex expression because of the action of genetic and environmental factors. We investigated whether the ACE gene D/I polymorphism is associated with severity of CF. Methods A cross-sectional study was performed, from 2009 to 2011, at University of Campinas – UNICAMP. We analyzed 180 patients for the most frequent mutations in the CFTR gene, presence of the ACE gene D/I polymorphism and clinical characteristics of CF. Results There was an association of the D/D genotype with early initiation of clinical manifestations (OR: 1.519, CI: 1.074 to 2.146, bacterium Burkholderia cepacia colonization (OR: 3.309, CI: 1.476 to 6.256 and Bhalla score (BS (p = 0.015. The association was observed in subgroups of patients which were defined by their CFTR mutation genotype (all patients; subgroup I: no mutation detected; subgroup II: one CFTR allele identified to mutation class I, II or III; subgroup III: both CFTR alleles identified to mutation class I, II and/or III. Conclusion An association between the D allele in the ACE gene and the severity of CF was found in our study.

  18. Association of ACTN3 R577X but not ACE I/D gene variants with elite rugby union player status and playing position.

    Science.gov (United States)

    Heffernan, S M; Kilduff, L P; Erskine, R M; Day, S H; McPhee, J S; McMahon, G E; Stebbings, G K; Neale, J P H; Lockey, S J; Ribbans, W J; Cook, C J; Vance, B; Raleigh, S M; Roberts, C; Bennett, M A; Wang, G; Collins, M; Pitsiladis, Y P; Williams, A G

    2016-03-01

    We aimed to quantify the ACE I/D and ACTN3 R577X (rs1815739) genetic variants in elite rugby athletes (rugby union and league) and compare genotype frequencies to controls and between playing positions. The rugby athlete cohort consisted of 507 Caucasian men, including 431 rugby union athletes that for some analyses were divided into backs and forwards and into specific positional groups: front five, back row, half backs, centers, and back three. Controls were 710 Caucasian men and women. Real-time PCR of genomic DNA was used to determine genotypes using TaqMan probes and groups were compared using χ(2) and odds ratio (OR) statistics. Correction of P values for multiple comparisons was according to Benjamini-Hochberg. There was no difference in ACE I/D genotype between groups. ACTN3 XX genotype tended to be underrepresented in rugby union backs (15.7%) compared with forwards (24.8%, P = 0.06). Interestingly, the 69 back three players (wings and full backs) in rugby union included only six XX genotype individuals (8.7%), with the R allele more common in the back three (68.8%) than controls (58.0%; χ(2) = 6.672, P = 0.04; OR = 1.60) and forwards (47.5%; χ(2) = 11.768, P = 0.01; OR = 2.00). Association of ACTN3 R577X with playing position in elite rugby union athletes suggests inherited fatigue resistance is more prevalent in forwards, while inherited sprint ability is more prevalent in backs, especially wings and full backs. These results also demonstrate the advantage of focusing genetic studies on a large cohort within a single sport, especially when intrasport positional differences exist, instead of combining several sports with varied demands and athlete characteristics. Copyright © 2016 the American Physiological Society.

  19. Combining MRI with PET for partial volume correction improves image-derived input functions in mice

    Energy Technology Data Exchange (ETDEWEB)

    Evans, Eleanor; Buonincontri, Guido [Wolfson Brain Imaging Centre, University of Cambridge, Cambridge (United Kingdom); Izquierdo, David [Athinoula A Martinos Centre, Harvard University, Cambridge, MA (United States); Methner, Carmen [Department of Medicine, University of Cambridge, Cambridge (United Kingdom); Hawkes, Rob C [Wolfson Brain Imaging Centre, University of Cambridge, Cambridge (United Kingdom); Ansorge, Richard E [Department of Physics, University of Cambridge, Cambridge (United Kingdom); Kreig, Thomas [Department of Medicine, University of Cambridge, Cambridge (United Kingdom); Carpenter, T Adrian [Wolfson Brain Imaging Centre, University of Cambridge, Cambridge (United Kingdom); Sawiak, Stephen J [Wolfson Brain Imaging Centre, University of Cambridge, Cambridge (United Kingdom); Behavioural and Clinical Neurosciences Institute, University of Cambridge, Cambridge (United Kingdom)

    2014-07-29

    Kinetic modelling in PET requires the arterial input function (AIF), defined as the time-activity curve (TAC) in plasma. This measure is challenging to obtain in mice due to low blood volumes, resulting in a reliance on image-based methods for AIF derivation. We present a comparison of PET- and MR-based region-of-interest (ROI) analysis to obtain image-derived AIFs from the left ventricle (LV) of a mouse model. ROI-based partial volume correction (PVC) was performed to improve quantification.

  20. Combining MRI with PET for partial volume correction improves image-derived input functions in mice

    International Nuclear Information System (INIS)

    Evans, Eleanor; Buonincontri, Guido; Izquierdo, David; Methner, Carmen; Hawkes, Rob C; Ansorge, Richard E; Kreig, Thomas; Carpenter, T Adrian; Sawiak, Stephen J

    2014-01-01

    Kinetic modelling in PET requires the arterial input function (AIF), defined as the time-activity curve (TAC) in plasma. This measure is challenging to obtain in mice due to low blood volumes, resulting in a reliance on image-based methods for AIF derivation. We present a comparison of PET- and MR-based region-of-interest (ROI) analysis to obtain image-derived AIFs from the left ventricle (LV) of a mouse model. ROI-based partial volume correction (PVC) was performed to improve quantification.

  1. Coexistence of ACE (I/D) and PAI-1 (4G/5G) gene variants in recurrent miscarriage in Polish population.

    Science.gov (United States)

    Kurzawińska, Grażyna; Barlik, Magdalena; Drews, Krzysztof; Różycka, Agata; Seremak-Mrozikiewicz, Agnieszka; Ożarowski, Marcin; Klejewski, Andrzej; Czerny, Bogusław; Wolski, Hubert

    2016-01-01

    Recurrent miscarriage (RM) is one of the most common obstetric complications. Numerous studies have suggested that genetic variants leading to an impaired balance between coagulation and fibrinolysis may contribute to elevated risk of pregnancy loss. The aim of the study was to investigate a possible association between angiotensin-converting enzyme (ACE, rs1799752) I/D and plasminogen activator inhibitor type 1 (PAI-1, rs1799768) 4G/5G polymorphisms with RM among Polish women. DNA was extracted from peripheral blood samples of 152 women with a history of ≥ 2 consecutive pregnancy losses before 22 weeks of gestation, and 180 healthy controls with at least 1 live birth at term and no history of pregnancy loss. Polymerase chain reaction (PCR) and restriction fragment length polymorphism (RFLP) were used to identify the polymorphisms. No statistically significant differences were found in genotype and allele frequencies of the studied polymorphisms. The most relevant difference between the study group and controls was found for the ID genotype distribution of the ACE gene (52.6 vs. 46.7%, OR = 1.27, p = 0.28). The analysis of genotype coexistence revealed a higher incidence of the combination of the ACE II and the PAI-1 4G/4G genotypes in the control group (10.0 vs.5.9% in control group; p = 0.17). The obtained results suggest no apparent association between the ACE I/D, PAI-1 4G/5G polymorphisms and increased RM susceptibility in the analyzed Polish population.

  2. Partial volume effect estimation and correction in the aortic vascular wall in PET imaging

    International Nuclear Information System (INIS)

    Burg, S; Le Guludec, D; Dupas, A; Stute, S; Dieudonné, A; Huet, P; Buvat, I

    2013-01-01

    We evaluated the impact of partial volume effect (PVE) in the assessment of arterial diseases with 18 FDG PET. An anthropomorphic digital phantom enabling the modeling of aorta related diseases like atherosclerosis and arteritis was used. Based on this phantom, we performed GATE Monte Carlo simulations to produce realistic PET images with a known organ segmentation and ground truth activity values. Images corresponding to 15 different activity-concentration ratios between the aortic wall and the blood and to 7 different wall thicknesses were generated. Using the PET images, we compared the theoretical wall-to-blood activity-concentration ratios (WBRs) with the measured WBRs obtained with five measurement methods: (1) measurement made by a physician (Expert), (2) automated measurement supposed to mimic the physician measurements (Max), (3) simple correction based on a recovery coefficient (Max-RC), (4) measurement based on an ideal VOI segmentation (Mean-VOI) and (5) measurement corrected for PVE using an ideal geometric transfer matrix (GTM) method. We found that Mean-VOI WBRs values were strongly affected by PVE. WBRs obtained by the physician measurement, by the Max method and by the Max-RC method were more accurate than WBRs obtained with the Mean-VOI approach. However Expert, Max and Max-RC WBRs strongly depended on the wall thickness. Only the GTM corrected WBRs did not depend on the wall thickness. Using the GTM method, we obtained more reproducible ratio values that could be compared across wall thickness. Yet, the feasibility of the implementation of a GTM-like method on real data remains to be studied. (paper)

  3. Gene polymorphisms and febrile neutropenia in acute leukemia--no association with IL-4, CCR-5, IL-1RA, but the MBL-2, ACE, and TLR-4 are associated with the disease in Turkish patients: a preliminary study.

    Science.gov (United States)

    Pehlivan, Mustafa; Sahin, Handan Haydaroğlu; Ozdilli, Kurşat; Onay, Hüseyin; Ozcan, Ali; Ozkinay, Ferda; Pehlivan, Sacide

    2014-07-01

    The aim of this study was to investigate the mannose-binding lectin 2 (MBL-2), interleukin (IL)-4, Toll-like receptor 4 (TLR-4), angiotensin converting enzyme (ACE), chemokine receptor 5 (CCR-5), and IL-1 receptor antagonist (RA) gene polymorphisms (GPs) in acute leukemias (ALs) and to evaluate their roles in febrile neutropenia (FN) resulting from chemotherapy. The study included 60 AL patients hospitalized between the period of July 2001 and August 2006. Polymorphisms for the genes ACE(I/D), CCR-5, IL-1RA, MBL-2, TLR-4, and IL-4 were typed by polymerase chain reaction (PCR) and/or PCR-restriction fragment length polymerase. Genotype frequencies for these genes were compared in the patient and control groups. The relationships between the genotypes and the body distribution of infections, pathogens, the duration of neutropenia, and febrile episodes in AL patients were evaluated. No significant differences in either the genotype distribution or the allelic frequencies of TLR-4, IL-4, CCR-5, IL-1RN GPs were observed between patients and healthy controls. The AB/BB genotype (53.3%) in the MBL-2 gene was found to be significantly higher in the AL patients compared with control groups. There were correlations between the presence of MBL-2, TLR-4, and ACE polymorphisms and clinical parameters due to FN. Overall, bacteremia was more common in MBL BB and ACE DD. Gram-positive bacteremia was more common in ACE for ID versus DD genotype. Gram-negative bacteremia was more common for both the MBL-2 AB/BB genotype and TLR-4 AG genotype. Median durations of febrile episodes were significantly shorter in ACE DD and MBL AB/BB. Although TLR-4, ACE, and MBL-2 GPs have been extensively investigated in different clinical pictures, this is the first study to evaluate the role of these polymorphisms in the genetic etiopathogenesis of FN in patients with ALs. As a conclusion, TLR-4, ACE, and MBL-2 genes might play roles in the genetic etiopathogenesis of FN in patients with ALs.

  4. Association of ACE and MDR1 Gene Polymorphisms with Steroid Resistance in Children with Idiopathic Nephrotic Syndrome.

    Science.gov (United States)

    Dhandapani, Mohanapriya Chinambedu; Venkatesan, Vettriselvi; Rengaswamy, Nammalwar Bollam; Gowrishankar, Kalpana; Nageswaran, Prahlad; Perumal, Venkatachalam

    2015-08-01

    The purpose of the study was to investigate the distribution of insertion/deletion (I/D) polymorphisms of the angiotensin-converting enzyme (ACE) gene and three exonic polymorphisms of the multidrug resistance 1 (MDR1) gene (C3435T, C1236T, and G2677T) in children diagnosed with idiopathic nephrotic syndrome (INS). The study group consisted of 100 healthy controls and 150 INS patients, of which 50 were steroid resistant. Genomic DNA from blood samples was isolated from both of these groups and genotyping of the ACE and MDR1 genes was performed by polymerase chain reaction (PCR) using specific primers. There was no significant difference observed in the genotypic distribution and D allele frequency of the ACE gene. The two single-nucleotide polymorphisms (SNPs), C1236T and C3435T, of the MDR1 gene showed no significance, whereas the SNP G2677T/A was significantly associated with the genotypes GT and GA of the MDR1 gene, indicating it may be a potential marker to detect drug resistance. Screening these polymorphisms will pave the way to better understand the molecular mechanisms of the disease, which may be useful in developing targeted therapies for INS patients.

  5. High-throughput interpretation of gene structure changes in human and nonhuman resequencing data, using ACE.

    Science.gov (United States)

    Majoros, William H; Campbell, Michael S; Holt, Carson; DeNardo, Erin K; Ware, Doreen; Allen, Andrew S; Yandell, Mark; Reddy, Timothy E

    2017-05-15

    The accurate interpretation of genetic variants is critical for characterizing genotype-phenotype associations. Because the effects of genetic variants can depend strongly on their local genomic context, accurate genome annotations are essential. Furthermore, as some variants have the potential to disrupt or alter gene structure, variant interpretation efforts stand to gain from the use of individualized annotations that account for differences in gene structure between individuals or strains. We describe a suite of software tools for identifying possible functional changes in gene structure that may result from sequence variants. ACE ('Assessing Changes to Exons') converts phased genotype calls to a collection of explicit haplotype sequences, maps transcript annotations onto them, detects gene-structure changes and their possible repercussions, and identifies several classes of possible loss of function. Novel transcripts predicted by ACE are commonly supported by spliced RNA-seq reads, and can be used to improve read alignment and transcript quantification when an individual-specific genome sequence is available. Using publicly available RNA-seq data, we show that ACE predictions confirm earlier results regarding the quantitative effects of nonsense-mediated decay, and we show that predicted loss-of-function events are highly concordant with patterns of intolerance to mutations across the human population. ACE can be readily applied to diverse species including animals and plants, making it a broadly useful tool for use in eukaryotic population-based resequencing projects, particularly for assessing the joint impact of all variants at a locus. ACE is written in open-source C ++ and Perl and is available from geneprediction.org/ACE. myandell@genetics.utah.edu or tim.reddy@duke.edu. Supplementary information is available at Bioinformatics online. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e

  6. Improved attenuation correction for respiratory gated PET/CT with extended-duration cine CT: a simulation study

    Science.gov (United States)

    Zhang, Ruoqiao; Alessio, Adam M.; Pierce, Larry A.; Byrd, Darrin W.; Lee, Tzu-Cheng; De Man, Bruno; Kinahan, Paul E.

    2017-03-01

    Due to the wide variability of intra-patient respiratory motion patterns, traditional short-duration cine CT used in respiratory gated PET/CT may be insufficient to match the PET scan data, resulting in suboptimal attenuation correction that eventually compromises the PET quantitative accuracy. Thus, extending the duration of cine CT can be beneficial to address this data mismatch issue. In this work, we propose to use a long-duration cine CT for respiratory gated PET/CT, whose cine acquisition time is ten times longer than a traditional short-duration cine CT. We compare the proposed long-duration cine CT with the traditional short-duration cine CT through numerous phantom simulations with 11 respiratory traces measured during patient PET/CT scans. Experimental results show that, the long-duration cine CT reduces the motion mismatch between PET and CT by 41% and improves the overall reconstruction accuracy by 42% on average, as compared to the traditional short-duration cine CT. The long-duration cine CT also reduces artifacts in PET images caused by misalignment and mismatch between adjacent slices in phase-gated CT images. The improvement in motion matching between PET and CT by extending the cine duration depends on the patient, with potentially greater benefits for patients with irregular breathing patterns or larger diaphragm movements.

  7. Positive Association of D Allele of ACE Gene With High Altitude Pulmonary Edema in Indian Population.

    Science.gov (United States)

    Bhagi, Shuchi; Srivastava, Swati; Tomar, Arvind; Bala Singh, Shashi; Sarkar, Soma

    2015-06-01

    High altitude pulmonary edema (HAPE) is a potentially fatal high altitude illness occurring as a result of hypobaric hypoxia with an unknown underlying genetic mechanism. Recent studies have shown a possible association between HAPE and polymorphisms in genes of the renin-angiotensin-aldosterone system (RAAS), which play a key role in sensitivity of an individual toward HAPE. For the present investigation, study groups consisted of HAPE patients (HAPE) and acclimatized control subjects (rCON). Four single-nucleotide polymorphisms (SNPs) were genotyped using restriction fragment length polymorphism (RFLP) analysis in genes of the RAAS pathway, specifically, renin (REN) C(-4063)T (rs41317140) and RENi8-83 (rs2368564), angiotensin (AGT) M(235)T (rs699), and angiotensin-converting enzyme (ACE) insertion/deletion (I/D) (rs1799752). Only the I/D polymorphism of the ACE gene showed a significant difference between the HAPE and rCON groups. The frequency of the D allele was found to be significantly higher in the HAPE group. Arterial oxygen saturation levels were significantly lower in the HAPE group compared with the rCON group and also decreased in the I/D and D/D genotypes compared with the I/I genotype in these groups. The other polymorphisms occurring in the REN and AGT genes were not significantly different between the 2 groups. These findings demonstrate a possible association of the I/D polymorphism of the ACE gene with the development of HAPE, with D/D being the at-risk genotype. Copyright © 2015 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.

  8. Partial volume effect correction in PET using regularized iterative deconvolution with variance control based on local topology

    International Nuclear Information System (INIS)

    Kirov, A S; Schmidtlein, C R; Piao, J Z

    2008-01-01

    Correcting positron emission tomography (PET) images for the partial volume effect (PVE) due to the limited resolution of PET has been a long-standing challenge. Various approaches including incorporation of the system response function in the reconstruction have been previously tested. We present a post-reconstruction PVE correction based on iterative deconvolution using a 3D maximum likelihood expectation-maximization (MLEM) algorithm. To achieve convergence we used a one step late (OSL) regularization procedure based on the assumption of local monotonic behavior of the PET signal following Alenius et al. This technique was further modified to selectively control variance depending on the local topology of the PET image. No prior 'anatomic' information is needed in this approach. An estimate of the noise properties of the image is used instead. The procedure was tested for symmetric and isotropic deconvolution functions with Gaussian shape and full width at half-maximum (FWHM) ranging from 6.31 mm to infinity. The method was applied to simulated and experimental scans of the NEMA NU 2 image quality phantom with the GE Discovery LS PET/CT scanner. The phantom contained uniform activity spheres with diameters ranging from 1 cm to 3.7 cm within uniform background. The optimal sphere activity to variance ratio was obtained when the deconvolution function was replaced by a step function few voxels wide. In this case, the deconvolution method converged in ∼3-5 iterations for most points on both the simulated and experimental images. For the 1 cm diameter sphere, the contrast recovery improved from 12% to 36% in the simulated and from 21% to 55% in the experimental data. Recovery coefficients between 80% and 120% were obtained for all larger spheres, except for the 13 mm diameter sphere in the simulated scan (68%). No increase in variance was observed except for a few voxels neighboring strong activity gradients and inside the largest spheres. Testing the method for

  9. Association of DD genotype of angiotensin-converting enzyme gene (I/D) polymorphism with hypertension among a North Indian population.

    Science.gov (United States)

    Rana, Garima; Yadav, Suniti; Joshi, Shipra; Saraswathy, K N

    2018-01-01

    Hypertension, a major risk factor for cardiovascular diseases, is among the leading causes of morbidity and mortality worldwide. Genetic predisposition to the risk of developing hypertension due to angiotensin-converting enzyme (ACE) gene insertion(I)/deletion(D) polymorphism (through altered serum ACE activity) is well documented among various populations. The present study investigated the possible association between ACE (DD) genotype and hypertension using a nested case-control study design including 451 individuals (of either sex in the age group 30-65 years) from a rural North Indian population practicing agriculture and lacto-vegetarianism. Blood Pressure was classified using JNC-7 criterion. Age- and sex-matched individuals were selected from normotensive (N-122), pre-hypertensive (N-123), hypertensive not on medication (N-122), and hypertensive on medication (N-84) categories. Amplification of DNA and genotyping of PCR product was done using standard protocols. From the analysis, comparatively higher frequency of individuals with DD genotype in the hypertensive category was observed, indicating a possible relation between DD genotype and hypertension. The odds ratio analysis revealed 2.225 (1.13-4.37)-fold significant increased risk for hypertension among cases, validating the vulnerability of individuals with DD genotype towards hypertension. Thus, the present study highlights the increased risk for developing hypertension due to ACE DD genotype in the studied population.

  10. Association of angiotensin-converting enzyme (ACE) and fatty acid binding protein 2 (FABP2) genes polymorphism with type 2 diabetes mellitus in Northern India.

    Science.gov (United States)

    Raza, Syed Tasleem; Fatima, Jalees; Ahmed, Faisal; Abbas, Shania; Zaidi, Zeashan Haider; Singh, Seema; Mahdi, Farzana

    2014-12-01

    Type 2 diabetes mellitus (T2DM) is growing in an epidemic manner across the world with an expected doubling of the incidence to millions of affected individuals in the last decades. At present, adequate data are not available regarding the ACE and FABP2 polymorphisms and their susceptibility with T2DM cases in the North Indian population. Thus we conceived the need for further study of ACE (I/D) and FABP2 (Ala54Thr) genes polymorphism and its susceptibility to T2DM in the North Indian population. In this study, a total of 300 subjects (including 190 T2DM cases and 110 controls) participated. ACE and FABP2 gene polymorphisms in the cases and controls were evaluated by polymerase chain reaction and restriction fragment length polymorphism. The frequencies of ACE I/I, I/D and D/D genotypes in T2DM cases and controls were 28.73%, 55.17%, 16.09% and 13.63%, 57.95%, 28.40%, respectively. The frequencies of FABP2 Ala54Ala, Ala54Thr and Thr54Thr in T2DM cases were 18.39%, 66.66%, 14.94% and 22.72%, 61.36%, 15.90% in controls, respectively. ACE I/I genotype was significantly more frequent in cases as compared to controls (p = 0.003, χ(2) = 9.13). It appears that the ACE I/I genotype frequency was significantly higher in the T2DM cases as compared to the controls. © The Author(s) 2013.

  11. Markerless PET motion correction: tracking in narrow gantries through optical fibers

    DEFF Research Database (Denmark)

    Jensen, Rasmus Ramsbøl; Olesen, Oline Vinter; Benjaminsen, Claus

    2015-01-01

    be accurate while only adding minimal complexity to the workflow. We present: Tracoline 2.0, a surface scanner prototype, which allows for markerless tracking in the clinic. The system uses structured light through optical fibre bundles, which easily fit in narrow gantries. The optical fibres also makes...... the system compatible with magnetic resonance (MR) imaging since all the electronics are moved away from the scanner. We demonstrate the system in a positron emission tomography (PET) study using the Siemens high resolution research tomography (HRRT). With two Ge/Ga-68 line sources fitted in a mannequin head...... for rotations up to ±25º. Based on the tracking results the PET frames were also successfully corrected for motion by aligning 10 s frames without motion for the stepwise experiment and aligning 1 s frames for the experiment with continuous motion. We have demonstrated and evaluated a system for markerless...

  12. The insertion-deletion polymorphism of the ACE gene is associated with increased blood pressure in women at the end of pregnancy.

    Science.gov (United States)

    Reshetnikov, Evgeny A; Akulova, Ludmila Y; Dobrodomova, Irina S; Dvornyk, Volodymyr Y; Polonikov, Alexey V; Churnosov, Mikhail I

    2015-09-01

    Malfunctioning of the cardiovascular system during pregnancy may be responsible for adverse effects on the 'mother-fetus' system. The cardiovascular system of a pregnant woman develops adaptation to the increased load. Angiotensin-converting enzyme (ACE) is known to play an important role in the adaptation. The present study was designed to investigate whether the insertion-deletion (I/D) polymorphism of the ACE gene is associated with the level of arterial blood pressure in women before and during pregnancy. The level of blood pressure was measured in 591 Russian women (Central Russia) before and during (37-40 weeks term) pregnancy. The women were divided into three groups which were hypertensive, hypotensive, and normotensive according to blood pressure level. Genotyping of the ACE I/D polymorphism was performed using polymerase chain reaction (PCR) and amplified fragment length polymorphism assay. Women with genotype DD showed the highest blood pressure level both during and at the end of pregnancy (pACE gene is associated with high blood pressure level at the end of pregnancy. © The Author(s) 2013.

  13. Dental artifacts in the head and neck region: implications for Dixon-based attenuation correction in PET/MR

    Energy Technology Data Exchange (ETDEWEB)

    Ladefoged, Claes N; Hansen, Adam E; Keller, Sune H; Fischer, Barbara M [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen East (Denmark); Rasmussen, Jacob H [Department of Oncology, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen East (Denmark); Law, Ian; Kjær, Andreas; Højgaard, Liselotte [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen East (Denmark); Lauze, Francois [Department of Computer Science, University of Copenhagen, Universitetsparken 5, 2100 Copenhagen East (Denmark); Beyer, Thomas [Centre for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20/4L, Vienna, A-1090 (Austria); Andersen, Flemming L [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen East (Denmark)

    2015-03-11

    In the absence of CT or traditional transmission sources in combined clinical positron emission tomography/magnetic resonance (PET/MR) systems, MR images are used for MR-based attenuation correction (MR-AC). The susceptibility effects due to metal implants challenge MR-AC in the neck region of patients with dental implants. The purpose of this study was to assess the frequency and magnitude of subsequent PET image distortions following MR-AC. A total of 148 PET/MR patients with clear visual signal voids on the attenuation map in the dental region were included in this study. Patients were injected with [{sup 18}F]-FDG, [{sup 11}C]-PiB, [{sup 18}F]-FET, or [{sup 64}Cu]-DOTATATE. The PET/MR data were acquired over a single-bed position of 25.8 cm covering the head and neck. MR-AC was based on either standard MR-AC{sub DIXON} or MR-AC{sub INPAINTED} where the susceptibility-induced signal voids were substituted with soft tissue information. Our inpainting algorithm delineates the outer contour of signal voids breaching the anatomical volume using the non-attenuation-corrected PET image and classifies the inner air regions based on an aligned template of likely dental artifact areas. The reconstructed PET images were evaluated visually and quantitatively using regions of interests in reference regions. The volume of the artifacts and the computed relative differences in mean and max standardized uptake value (SUV) between the two PET images are reported. The MR-based volume of the susceptibility-induced signal voids on the MR-AC attenuation maps was between 1.6 and 520.8 mL. The corresponding/resulting bias of the reconstructed tracer distribution was localized mainly in the area of the signal void. The mean and maximum SUVs averaged across all patients increased after inpainting by 52% (± 11%) and 28% (± 11%), respectively, in the corrected region. SUV underestimation decreased with the distance to the signal void and correlated with the volume of the susceptibility

  14. Establishment of an open database of realistic simulated data for evaluation of partial volume correction techniques in brain PET/MR

    Energy Technology Data Exchange (ETDEWEB)

    Mota, Ana [Instituto de Biofísica e Engenharia Biomédica, FC-UL, Lisboa (Portugal); Institute of Nuclear Medicine, UCL, London (United Kingdom); Cuplov, Vesna [Instituto de Biofísica e Engenharia Biomédica, FC-UL, Lisboa (Portugal); Schott, Jonathan; Hutton, Brian; Thielemans, Kris [Institute of Nuclear Medicine, UCL, London (United Kingdom); Drobnjak, Ivana [Centre of Medical Image Computing, UCL, London (United Kingdom); Dickson, John [Institute of Nuclear Medicine, UCL, London (United Kingdom); Bert, Julien [INSERM UMR1101, LaTIM, CHRU de Brest, Brest (France); Burgos, Ninon; Cardoso, Jorge; Modat, Marc; Ourselin, Sebastien [Centre of Medical Image Computing, UCL, London (United Kingdom); Erlandsson, Kjell [Institute of Nuclear Medicine, UCL, London (United Kingdom)

    2015-05-18

    The Partial Volume (PV) effect in Positron Emission Tomography (PET) imaging leads to loss in quantification accuracy, which manifests in PV effects (small objects occupy partially the sensitive volume of the imaging instrument, resulting in blurred images). Simultaneous acquisition of PET and Magnetic Resonance Imaging (MRI) produces concurrent metabolic and anatomical information. The latter has proved to be very helpful for the correction of PV effects. Currently, there are several techniques used for PV correction. They can be applied directly during the reconstruction process or as a post-processing step after image reconstruction. In order to evaluate the efficacy of the different PV correction techniques in brain- PET, we are constructing a database of simulated data. Here we present the framework and steps involved in constructing this database. Static 18F-FDG epilepsy and 18F-Florbetapir amyloid dementia PET/MR were selected because of their very different characteristics. The methodology followed was based on four main steps: Image pre-processing, Ground Truth (GT) generation, MRI and PET data simulation and reconstruction. All steps used Open Source software and can therefore be repeated at any centre. The framework as well as the database will be freely accessible. Tools used included GIF, FSL, POSSUM, GATE and STIR. The final data obtained after simulation, involving raw or reconstructed PET data together with corresponding MRI datasets, were close to the original patient data. Besides, there is the advantage that data can be compared with the GT. We indicate several parameters that can be improved and optimized.

  15. Establishment of an open database of realistic simulated data for evaluation of partial volume correction techniques in brain PET/MR

    International Nuclear Information System (INIS)

    Mota, Ana; Cuplov, Vesna; Schott, Jonathan; Hutton, Brian; Thielemans, Kris; Drobnjak, Ivana; Dickson, John; Bert, Julien; Burgos, Ninon; Cardoso, Jorge; Modat, Marc; Ourselin, Sebastien; Erlandsson, Kjell

    2015-01-01

    The Partial Volume (PV) effect in Positron Emission Tomography (PET) imaging leads to loss in quantification accuracy, which manifests in PV effects (small objects occupy partially the sensitive volume of the imaging instrument, resulting in blurred images). Simultaneous acquisition of PET and Magnetic Resonance Imaging (MRI) produces concurrent metabolic and anatomical information. The latter has proved to be very helpful for the correction of PV effects. Currently, there are several techniques used for PV correction. They can be applied directly during the reconstruction process or as a post-processing step after image reconstruction. In order to evaluate the efficacy of the different PV correction techniques in brain- PET, we are constructing a database of simulated data. Here we present the framework and steps involved in constructing this database. Static 18F-FDG epilepsy and 18F-Florbetapir amyloid dementia PET/MR were selected because of their very different characteristics. The methodology followed was based on four main steps: Image pre-processing, Ground Truth (GT) generation, MRI and PET data simulation and reconstruction. All steps used Open Source software and can therefore be repeated at any centre. The framework as well as the database will be freely accessible. Tools used included GIF, FSL, POSSUM, GATE and STIR. The final data obtained after simulation, involving raw or reconstructed PET data together with corresponding MRI datasets, were close to the original patient data. Besides, there is the advantage that data can be compared with the GT. We indicate several parameters that can be improved and optimized.

  16. Device-dependent activity estimation and decay correction of radionuclide mixtures with application to Tc-94m PET studies

    International Nuclear Information System (INIS)

    Smith, Mark F.; Daube-Witherspoon, Margaret E.; Plascjak, Paul S.; Szajek, Lawrence P.; Carson, Richard E.; Everett, James R.; Green, Shielah L.; Territo, Paul R.; Balaban, Robert S.; Bacharach, Stephen L.; Eckelman, William C.

    2001-01-01

    Multi-instrument activity estimation and decay correction techniques were developed for radionuclide mixtures, motivated by the desire for accurate quantitation of Tc-94m positron emission tomography (PET) studies. Tc-94m and byproduct Tc isotopes were produced by proton irradiation of enriched Mo-94 and natural Mo targets. Mixture activities at the end of bombardment were determined with a calibrated high purity germanium detector. The activity fractions of the greatest mixture impurities relative to 100% for Tc-94m averaged 10.0% (Tc-94g) and 3.3% (Tc-93) for enriched targets and 10.1% (Tc-94g), 11.0% (Tc-95), 255.8% (Tc-96m), and 7.2% (Tc-99m) for natural targets. These radioisotopes have different half-lives (e.g., 52.5 min for Tc-94m, 293 min for Tc-94g), positron branching ratios (e.g., 0.72 for Tc-94m, 0.11 for Tc-94g) and gamma ray emissions for themselves and their short-lived, excited Mo daughters. This complicates estimation of injected activity with a dose calibrator, in vivo activity with PET and blood sample activity with a gamma counter. Decay correction using only the Tc-94m half-life overestimates activity and is inadequate. For this reason analytic formulas for activity estimation and decay correction of radionuclide mixtures were developed. Isotope-dependent sensitivity factors for a PET scanner, dose calibrator, and gamma counter were determined using theoretical sensitivity models and fits of experimental decay curves to sums of exponentials with fixed decay rates. For up to 8 h after the end of bombardment with activity from enriched and natural Mo targets, decay-corrected activities were within 3% of the mean for three PET studies of a uniform cylinder, within 3% of the mean for six dose calibrator decay studies, and within 6% of the mean for four gamma counter decay studies. Activity estimation and decay correction for Tc-94m mixtures enable routine use of Tc-94m in quantitative PET, as illustrated by application to a canine Tc-94m sestamibi

  17. Simulation of a MR–PET protocol for staging of head-and-neck cancer including Dixon MR for attenuation correction

    Energy Technology Data Exchange (ETDEWEB)

    Eiber, Matthias, E-mail: matthias.eiber@tum.de [Department of Radiology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675 Munich (Germany); Souvatzoglou, Michael, E-mail: msouvatz@yahoo.de [Department of Nuclear Medicine, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675 Munich (Germany); Pickhard, Anja, E-mail: a.pickhard@lrz.tum.de [Department of Otorhinolaryngology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675 Munich (Germany); Loeffelbein, Denys J., E-mail: denys.loeffelbein@gmx.de [Department of Maxillofacial Surgery, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675 Munich (Germany); Knopf, Andreas, E-mail: andreas.knopf@tum.de [Department of Otorhinolaryngology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675 Munich (Germany); Holzapfel, Konstantin, E-mail: holzapfel@roe.med.tum.de [Department of Radiology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675 Munich (Germany); Martinez-Möller, Axel, E-mail: a.martinez-moller@lrz.tu-muenchen.de [Department of Nuclear Medicine, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675 Munich (Germany); and others

    2012-10-15

    Purpose: To simulate and optimize a MR protocol for squamous cell cancer of the head and neck (HNSCC) patients for potential future use in an integrated whole-body MR–PET scanner. Materials and methods: On a clinical 3T scanner, which is the basis for a recently introduced fully integrated whole-body MR–PET, 20 patients with untreated HNSCC routinely staged with 18F-FDG PET/CT underwent a dedicated MR protocol for the neck. Moreover, a whole-body Dixon MR-sequence was applied, which is used for attenuation correction on a recently introduced hybrid MR–PET scanner. In a subset of patients volume-interpolated-breathhold (VIBE) T1w-sequences for lungs and liver were added. Total imaging time was analyzed for both groups. The quality of the delineation of the primary tumor (scale 0–3) and the presence or absence of lymph node metastases (scale 1–5) was evaluated for CT, MR, PET/CT and a combination of MR and PET to ensure that the MR–PET fusion does not cause a loss of diagnostic capability. PET was used to identify distant metastases. The PET dataset for simulated MR/PET was based on a segmentation of the CT data into 4 classes according to the approach of the Dixon MR-sequence for MR–PET. Standard of reference was histopathology in 19 cases. In one case no histopathological confirmation of a primary tumor could be achieved. Results: Mean imaging time was 35:17 min (range: 31:08–42:42 min) for the protocol including sequences for local staging and attenuation correction and 44:17 min (range: 35:44–54:58) for the extended protocol. Although not statistically significant a combination of MR and PET performed better in the delineation of the primary tumor (mean 2.20) compared to CT (mean 1.40), MR (1.95) and PET/CT (2.15) especially in patients with dental implants. PET/CT and combining MR and PET performed slightly better than CT and MR for the assessment of lymph node metastases. Two patients with distant metastases were only identified by PET

  18. Effects of motion correction for dynamic [11C]Raclopride brain PET data on the evaluation of endogenous dopamine release in striatum

    International Nuclear Information System (INIS)

    Lee, Jae Sung; Kim, Yu Kyeong; Cho, Sang Soo; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul; Kim, Sang Eun; Choe, Yearn Seong; Kang, Eun Joo

    2005-01-01

    Neuroreceptor PET studies require 60-120 minutes to complete and head motion of the subject during the PET scan increases the uncertainty in measured activity. In this study, we investigated the effects of the data-driven head motion correction on the evaluation of endogenous dopamine release (DAR) in the striatum during the motor task which might have caused significant head motion artifact. [ 11 C]raclopride PET scans on 4 normal volunteers acquired with bolus plus constant infusion protocol were retrospectively analyzed. Following the 50 min resting period, the participants played a video game with a momentary reward for 40 min. Dynamic frames acquired during the equilibrium condition (pre-task: 30-50 min, task: 70-90 min, post-task:110-120 min) were realigned to the first frame in pre-task condition. Intra-condition registrations between the frames were performed, and average image for each condition was created and registered to the pre-task image (inter-condition registration). Pre-task PET image was then co-registered to own MRI of each participant and transformation parameters were reapplied to the others. Volumes of interest (VOI) for dorsal putamen (PU) and caudate (CA), ventral striatum (VS), and cerebellum were defined on the MRI. Binding potential (BP) was measured and DAR was calculated as the percent change of BP during and after the task. SPM analyses on the BP parametric images were also performed to explore the regional difference in the effects of head motion on BP and DAR estimation. Changes in position and orientation of the striatum during the PET scans were observed before the head motion correction. BP values at pre-task condition were not changed significantly after the intra-condition registration. However, the BP values during and after the task and DAR were significantly changed after the correction. SPM analysis also showed that the extent and significance of the BP differences were significantly changed by the head motion correction

  19. Computer simulations suggest that acute correction of hyperglycaemia with an insulin bolus protocol might be useful in brain FDG PET

    Energy Technology Data Exchange (ETDEWEB)

    Buchert, R.; Brenner, W.; Apostolova, I.; Mester, J.; Clausen, M. [University Medical Center Hamburg-Eppendorf (Germany). Dept. of Nuclear Medicine; Santer, R. [University Medical Center Hamburg-Eppendorf (Germany). Center for Gynaecology, Obstetrics and Paediatrics; Silverman, D.H.S. [David Geffen School of Medicine at UCLA, Los Angeles, CA (United States). Dept. of Molecular and Medical Pharmacology

    2009-07-01

    FDG PET in hyperglycaemic subjects often suffers from limited statistical image quality, which may hamper visual and quantitative evaluation. In our study the following insulin bolus protocol is proposed for acute correction of hyperglycaemia (> 7.0 mmol/l) in brain FDG PET. (i) Intravenous bolus injection of short-acting insulin, one I.E. for each 0.6 mmol/l blood glucose above 7.0. (ii) If 20 min after insulin administration plasma glucose is {<=} 7.0 mmol/l, proceed to (iii). If insulin has not taken sufficient effect step back to (i). Compute insulin dose with the updated blood glucose level. (iii) Wait further 20 min before injection of FDG. (iv) Continuous supervision of the patient during the whole scanning procedure. The potential of this protocol for improvement of image quality in brain FDG PET in hyperglycaemic subjects was evaluated by computer simulations within the Sokoloff model. A plausibility check of the prediction of the computer simulations on the magnitude of the effect that might be achieved by correction of hyperglycaemia was performed by retrospective evaluation of the relation between blood glucose level and brain FDG uptake in 89 subjects in whom FDG PET had been performed for diagnosis of Alzheimer's disease. The computer simulations suggested that acute correction of hyperglycaemia according to the proposed bolus insulin protocol might increase the FDG uptake of the brain by up to 80%. The magnitude of this effect was confirmed by the patient data. The proposed management protocol for acute correction of hyperglycaemia with insulin has the potential to significantly improve the statistical quality of brain FDG PET images. This should be confirmed in a prospective study in patients. (orig.)

  20. Computer simulations suggest that acute correction of hyperglycaemia with an insulin bolus protocol might be useful in brain FDG PET

    International Nuclear Information System (INIS)

    Buchert, R.; Brenner, W.; Apostolova, I.; Mester, J.; Clausen, M.; Santer, R.; Silverman, D.H.S.

    2009-01-01

    FDG PET in hyperglycaemic subjects often suffers from limited statistical image quality, which may hamper visual and quantitative evaluation. In our study the following insulin bolus protocol is proposed for acute correction of hyperglycaemia (> 7.0 mmol/l) in brain FDG PET. (i) Intravenous bolus injection of short-acting insulin, one I.E. for each 0.6 mmol/l blood glucose above 7.0. (ii) If 20 min after insulin administration plasma glucose is ≤ 7.0 mmol/l, proceed to (iii). If insulin has not taken sufficient effect step back to (i). Compute insulin dose with the updated blood glucose level. (iii) Wait further 20 min before injection of FDG. (iv) Continuous supervision of the patient during the whole scanning procedure. The potential of this protocol for improvement of image quality in brain FDG PET in hyperglycaemic subjects was evaluated by computer simulations within the Sokoloff model. A plausibility check of the prediction of the computer simulations on the magnitude of the effect that might be achieved by correction of hyperglycaemia was performed by retrospective evaluation of the relation between blood glucose level and brain FDG uptake in 89 subjects in whom FDG PET had been performed for diagnosis of Alzheimer's disease. The computer simulations suggested that acute correction of hyperglycaemia according to the proposed bolus insulin protocol might increase the FDG uptake of the brain by up to 80%. The magnitude of this effect was confirmed by the patient data. The proposed management protocol for acute correction of hyperglycaemia with insulin has the potential to significantly improve the statistical quality of brain FDG PET images. This should be confirmed in a prospective study in patients. (orig.)

  1. The ACE Gene Insertion/Deletion Polymorphism and Cerebrovascular Diseases in Uzbek Patients with Arterial Hypertension

    Directory of Open Access Journals (Sweden)

    Nargiza U. Makhkamova

    2016-09-01

    Full Text Available The aim of the present study was to investigate the association between the ACE gene I/D polymorphism and the development of hypertensive encephalopathy (HE in Uzbek patients with hypertension (HT. Materials and methods: The study included 91 male patients aged from 32 to 74 years (mean age 52.5±9.2 with HT Grade 1, 2 and 3 (ESH/ESC, 2013 [4] and presence of HE. All patients were checked on office BP using Korotkov’s method and ambulatory blood pressure monitoring (ABPM. Intima-media thickness (IMT of the carotid artery was measured by a 7.5MHz high-resolution ultrasound. Genomic DNA was isolated from peripheral blood using the DiatomTM DNA Prep 200 Kit according to the manufacturer's protocol. ACE gene I/D polymorphism genotypes were determined by PCR. Results: Among HT patients with HE, we have identified a statistically significant predominance of ID genotype carriers (65.9% against carriers of the II genotype (18.75 and DD genotype (15.4% (P=0.000; the frequency of I and D alleles was 51.6% and 48.4%, respectively (P>0.05. Comparative analysis showed a possible association between the ID genotype/D allele and HE development in HT patients, according to the general model (OR = 6.36; 95% CI 3.04 -13.31; p=0.000 and multiplicative model (OR = 2.02; 95% CI 1.25 -3.27; p=0.004 of inheritance. High grades of HT were predominant in carriers of the DD genotype. IMT was significantly higher in carriers of the DD genotype than in carriers of the II and ID genotypes. The carriage of D allele was associated with the highest levels of TC, TG, and VLDL-C. Carriers of the DD genotype were characterized by higher values of daytime SBP, nighttime SBP variability and nighttime SBP load.

  2. Insertion/deletion polymorphism of the ACE gene and adherence to ACE inhibitors

    NARCIS (Netherlands)

    Schelleman, H; Klungel, O H; van Duijn, C M; Witteman, J C M; Hofman, A; de Boer, A; Stricker, B H Ch

    AIMS: We investigated whether the insertion/deletion (I/D) polymorphism of the ACE gene modified the adherence to ACE inhibitors as measured by the discontinuation of an ACE inhibitor, or addition of another antihypertensive drug. METHODS: This was a cohort study among 239 subjects who started ACE

  3. Tetra primer ARMS-PCR relates folate/homocysteine pathway genes and ACE gene polymorphism with coronary artery disease.

    Science.gov (United States)

    Masud, Rizwan; Qureshi, Irfan Zia

    2011-09-01

    Cardiovascular disorders and coronary artery disease (CAD) are significant contributors to morbidity and mortality in heart patients. As genes of the folate/homocysteine pathway have been linked with the vascular disease, we investigated association of these gene polymorphisms with CAD/myocardial infarction (MI) using the novel approach of tetraprimer ARMS-PCR. A total of 230 participants (129 MI cases, 101 normal subjects) were recruited. We genotyped rs1801133 and rs1801131 SNPs in 5'10' methylenetetrahydrofolate reductase (MTHFR), rs1805087 SNP in 5' methyltetrahydrofolate homocysteine methyltransferase (MTR), rs662 SNP in paroxanse1 (PON1), and rs5742905 polymorphism in cystathionine beta synthase (CBS). Angiotensin converting enzyme (ACE) insertion/deletion polymorphism was detected through conventional PCR. Covariates included blood pressure, fasting blood sugar, serum cholesterol, and creatinine concentrations. Our results showed allele frequencies at rs1801133, rs1801131, rs1805087 and the ACE insertion/deletion (I/D) polymorphism varied between cases and controls. Logistic regression, after adjusting for covariates, demonstrated significant associations of rs1801133 and rs1805087 with CAD in the additive, dominant, and genotype model. In contrast, ACE I/D polymorphism was significantly related with CAD where recessive model was applied. Gene-gene interaction against the disease status revealed two polymorphism groups: rs1801133, rs662, and rs1805087; and rs1801131, rs662, and ACE I/D. Only the latter interaction maintained significance after adjusted for covariates. Our study concludes that folate pathway variants exert contributory influence on susceptibility to CAD. We further suggest that tetraprimer ARMS-PCR successfully resolves the genotypes in selected samples and might prove to be a superior technique compared to the conventional approach.

  4. Evaluation of a direct motion estimation/correction method in respiratory-gated PET/MRI with motion-adjusted attenuation.

    Science.gov (United States)

    Bousse, Alexandre; Manber, Richard; Holman, Beverley F; Atkinson, David; Arridge, Simon; Ourselin, Sébastien; Hutton, Brian F; Thielemans, Kris

    2017-06-01

    Respiratory motion compensation in PET/CT and PET/MRI is essential as motion is a source of image degradation (motion blur, attenuation artifacts). In previous work, we developed a direct method for joint image reconstruction/motion estimation (JRM) for attenuation-corrected (AC) respiratory-gated PET, which uses a single attenuation-map (μ-map). This approach was successfully implemented for respiratory-gated PET/CT, but since it relied on an accurate μ-map for motion estimation, the question of its applicability in PET/MRI is open. The purpose of this work is to investigate the feasibility of JRM in PET/MRI and to assess the robustness of the motion estimation when a degraded μ-map is used. We performed a series of JRM reconstructions from simulated PET data using a range of simulated Dixon MRI sequence derived μ-maps with wrong attenuation values in the lungs, from -100% (no attenuation) to +100% (double attenuation), as well as truncated arms. We compared the estimated motions with the one obtained from JRM in ideal conditions (no noise, true μ-map as an input). We also applied JRM on 4 patient datasets of the chest, 3 of them containing hot lesions. Patient list-mode data were gated using a principal component analysis method. We compared SUV max values of the JRM reconstructed activity images and non motion-corrected images. We also assessed the estimated motion fields by comparing the deformed JRM-reconstructed activity with individually non-AC reconstructed gates. Experiments on simulated data showed that JRM-motion estimation is robust to μ-map degradation in the sense that it produces motion fields similar to the ones obtained when using the true μ-map, regardless of the attenuation errors in the lungs (PET/MRI clinical datasets. It provides a potential alternative to existing methods where the motion fields are pre-estimated from separate MRI measurements. © 2017 University College London (UCL). Medical Physics published by Wiley Periodicals, Inc

  5. The evaluation of angiotensin-converting enzyme (ACE) gene I/D and IL-4 gene intron 3 VNTR polymorphisms in coronary artery disease.

    Science.gov (United States)

    Basol, Nursah; Celik, Atac; Karakus, Nevin; Ozturk, Sibel Demir; Ozsoy, Sibel Demir; Yigit, Serbulent

    2014-01-01

    Genetic polymorphism is a strong risk factor for coronary artery disease (CAD). In the present study, our aim was to evaluate angiotensin-converting enzyme (ACE) gene I/D polymorphism and interleukin-4 (IL-4) gene Intron 3 variable number of tandem repeat (VNTR) polymorphism in CAD. One hundred and twenty-four CAD patients and one hundred and twenty-three controls were enrolled. Genomic DNA was isolated and genotyped using polymerase chain reaction (PCR) analyses. The risk associated with inheriting the combined genotypes for the two polymorphisms were evaluated and it was found that the individuals who were P2P2-homozygous at IL-4 gene intron 3 VNTR and DD-homozygous at ACE gene I/D have a higher risk of developing CAD. Although, there is no correlation between IL4 VNTR polymorphism and ACE gene polymorphism and CAD, there is a strong association between CAD and co-existence of IL-4 VNTR and ACE gene polymorphisms in the Turkish population. Copyright © 2014 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  6. Relationship of the MTHFD1 (rs2236225, eNOS (rs1799983, CBS (rs2850144 and ACE (rs4343 gene polymorphisms in a population of Iranian pediatric patients with congenital heart defects

    Directory of Open Access Journals (Sweden)

    Mehri Khatami

    2017-09-01

    Full Text Available Congenital heart defects are structural cardiovascular malformations that arise from abnormal formation of the heart or major blood vessels during the fetal period. To investigate the association of 4 single nucleotide polymorphisms (SNPs in the MTHFD1, eNOS, CBS and ACE genes, we evaluated their relationship with CHD in Iranian patients. In this case–control study, a total of 102 children with CHD and 98 control children were enrolled. Four SNPs including MTHFD1 G1958A, eNOS G894T, CBS C-4673G and ACE A2350G were genotyped by PCR-SSCP, Multiplex ARMS PCR and PCR-RFLP methods and confirmed by direct sequencing. We genotyped 102 patients and 98 controls for four polymorphisms by statistically analysis. There were three SNPs including MTHFD1 G1958A, eNOS G894T and ACE A2350G which might increase the risk of CHD, but CBS C-4673G was not significantly different between patients and controls. (P = 0.017, P = 0.048, P = 0.025 and P = 0.081 respectively. The allele frequencies of three SNPs for MTHFD1 G1958A, eNOS G894T and ACE A2350G in CHD are higher than that in control. Our results show that there is a significant relationship between MTHFD1 G1958A, eNOS G894T and ACE A2350G polymorphisms with CHD. Therefore, The AA and GA genotypes of MTHFD1 G1958A, TT and GT genotypes of eNOS G894T and the AA and GA genotypes of ACE A2350G are susceptible factors for CHD and may increase the risk of CHD.

  7. Relationship of the MTHFD1 (rs2236225), eNOS (rs1799983), CBS (rs2850144) and ACE (rs4343) gene polymorphisms in a population of Iranian pediatric patients with congenital heart defects.

    Science.gov (United States)

    Khatami, Mehri; Ratki, Farzaneh Morteza; Tajfar, Saba; Akrami, Fatemeh

    2017-09-01

    Congenital heart defects are structural cardiovascular malformations that arise from abnormal formation of the heart or major blood vessels during the fetal period. To investigate the association of 4 single nucleotide polymorphisms (SNPs) in the MTHFD1, eNOS, CBS and ACE genes, we evaluated their relationship with CHD in Iranian patients. In this case-control study, a total of 102 children with CHD and 98 control children were enrolled. Four SNPs including MTHFD1 G1958A, eNOS G894T, CBS C-4673G and ACE A2350G were genotyped by PCR-SSCP, Multiplex ARMS PCR and PCR-RFLP methods and confirmed by direct sequencing. We genotyped 102 patients and 98 controls for four polymorphisms by statistically analysis. There were three SNPs including MTHFD1 G1958A, eNOS G894T and ACE A2350G which might increase the risk of CHD, but CBS C-4673G was not significantly different between patients and controls. (P = 0.017, P = 0.048, P = 0.025 and P = 0.081 respectively). The allele frequencies of three SNPs for MTHFD1 G1958A, eNOS G894T and ACE A2350G in CHD are higher than that in control. Our results show that there is a significant relationship between MTHFD1 G1958A, eNOS G894T and ACE A2350G polymorphisms with CHD. Therefore, The AA and GA genotypes of MTHFD1 G1958A, TT and GT genotypes of eNOS G894T and the AA and GA genotypes of ACE A2350G are susceptible factors for CHD and may increase the risk of CHD. Copyright © 2017. Published by Elsevier Taiwan.

  8. Dye shift: a neglected source of genotyping error in molecular ecology.

    Science.gov (United States)

    Sutton, Jolene T; Robertson, Bruce C; Jamieson, Ian G

    2011-05-01

    Molecular ecologists must be vigilant in detecting and accounting for genotyping error, yet potential errors stemming from dye-induced mobility shift (dye shift) may be frequently neglected and largely unknown to researchers who employ 3-primer systems with automated genotyping. When left uncorrected, dye shift can lead to mis-scoring alleles and even to falsely calling new alleles if different dyes are used to genotype the same locus in subsequent reactions. When we used four different fluorophore labels from a standard dye set to genotype the same set of loci, differences in the resulting size estimates for a single allele ranged from 2.07 bp to 3.68 bp. The strongest effects were associated with the fluorophore PET, and relative degree of dye shift was inversely related to locus size. We found little evidence in the literature that dye shift is regularly accounted for in 3-primer studies, despite knowledge of this phenomenon existing for over a decade. However, we did find some references to erroneous standard correction factors for the same set of dyes that we tested. We thus reiterate the need for strict quality control when attempting to reduce possible sources of genotyping error, and in cases where different dyes are applied to a single locus, perhaps mistakenly, we strongly discourage researchers from assuming generic correction patterns. © 2011 Blackwell Publishing Ltd.

  9. Fully 3D iterative scatter-corrected OSEM for HRRT PET using a GPU

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyung Sang; Ye, Jong Chul, E-mail: kssigari@kaist.ac.kr, E-mail: jong.ye@kaist.ac.kr [Bio-Imaging and Signal Processing Lab., Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), 335 Gwahak-no, Yuseong-gu, Daejon 305-701 (Korea, Republic of)

    2011-08-07

    Accurate scatter correction is especially important for high-resolution 3D positron emission tomographies (PETs) such as high-resolution research tomograph (HRRT) due to large scatter fraction in the data. To address this problem, a fully 3D iterative scatter-corrected ordered subset expectation maximization (OSEM) in which a 3D single scatter simulation (SSS) is alternatively performed with a 3D OSEM reconstruction was recently proposed. However, due to the computational complexity of both SSS and OSEM algorithms for a high-resolution 3D PET, it has not been widely used in practice. The main objective of this paper is, therefore, to accelerate the fully 3D iterative scatter-corrected OSEM using a graphics processing unit (GPU) and verify its performance for an HRRT. We show that to exploit the massive thread structures of the GPU, several algorithmic modifications are necessary. For SSS implementation, a sinogram-driven approach is found to be more appropriate compared to a detector-driven approach, as fast linear interpolation can be performed in the sinogram domain through the use of texture memory. Furthermore, a pixel-driven backprojector and a ray-driven projector can be significantly accelerated by assigning threads to voxels and sinograms, respectively. Using Nvidia's GPU and compute unified device architecture (CUDA), the execution time of a SSS is less than 6 s, a single iteration of OSEM with 16 subsets takes 16 s, and a single iteration of the fully 3D scatter-corrected OSEM composed of a SSS and six iterations of OSEM takes under 105 s for the HRRT geometry, which corresponds to acceleration factors of 125x and 141x for OSEM and SSS, respectively. The fully 3D iterative scatter-corrected OSEM algorithm is validated in simulations using Geant4 application for tomographic emission and in actual experiments using an HRRT.

  10. A comparison of five partial volume correction methods for Tau and Amyloid PET imaging with [18F]THK5351 and [11C]PIB.

    Science.gov (United States)

    Shidahara, Miho; Thomas, Benjamin A; Okamura, Nobuyuki; Ibaraki, Masanobu; Matsubara, Keisuke; Oyama, Senri; Ishikawa, Yoichi; Watanuki, Shoichi; Iwata, Ren; Furumoto, Shozo; Tashiro, Manabu; Yanai, Kazuhiko; Gonda, Kohsuke; Watabe, Hiroshi

    2017-08-01

    To suppress partial volume effect (PVE) in brain PET, there have been many algorithms proposed. However, each methodology has different property due to its assumption and algorithms. Our aim of this study was to investigate the difference among partial volume correction (PVC) method for tau and amyloid PET study. We investigated two of the most commonly used PVC methods, Müller-Gärtner (MG) and geometric transfer matrix (GTM) and also other three methods for clinical tau and amyloid PET imaging. One healthy control (HC) and one Alzheimer's disease (AD) PET studies of both [ 18 F]THK5351 and [ 11 C]PIB were performed using a Eminence STARGATE scanner (Shimadzu Inc., Kyoto, Japan). All PET images were corrected for PVE by MG, GTM, Labbé (LABBE), Regional voxel-based (RBV), and Iterative Yang (IY) methods, with segmented or parcellated anatomical information processed by FreeSurfer, derived from individual MR images. PVC results of 5 algorithms were compared with the uncorrected data. In regions of high uptake of [ 18 F]THK5351 and [ 11 C]PIB, different PVCs demonstrated different SUVRs. The degree of difference between PVE uncorrected and corrected depends on not only PVC algorithm but also type of tracer and subject condition. Presented PVC methods are straight-forward to implement but the corrected images require careful interpretation as different methods result in different levels of recovery.

  11. Evaluation of Dixon Sequence on Hybrid PET/MR Compared with Contrast-Enhanced PET/CT for PET-Positive Lesions

    International Nuclear Information System (INIS)

    Jeong, Ju Hye; Cho, Ihn Ho; Kong, Eun Jung; Chun, Kyung Ah

    2014-01-01

    Hybrid positron emission tomography and magnetic resonance (PET/MR) imaging performs a two-point Dixon MR sequence for attenuation correction. However, MR data in hybrid PET/MR should provide anatomic and morphologic information as well as an attenuation map. We evaluated the Dixon sequence of hybrid PET/MR for anatomic correlation of PET-positive lesions compared with contrast-enhanced PET/computed tomography (CT) in patients with oncologic diseases. Twelve patients underwent a single injection, dual imaging protocol. PET/CT was performed with an intravenous contrast agent (85±13 min after 18 F-FDG injection of 403± 45 MBq) and then (125±19 min after injection) PET/MR was performed. Attenuation correction and anatomic allocation of PET were performed using contrast-enhanced CT for PET/CT and Dixon MR sequence for hybrid PET/MR. The Dixon MR sequence and contrast-enhanced CT were compared for anatomic correlation of PET-positive lesions (scoring scale ranging from 0 to 3 for visual ratings). Additionally, standardized uptake values (SUVs) for the detected lesions were assessed for quantitative comparison. Both hybrid PET/MR and contrast-enhanced PET/CT identified 55 lesions with increased FDG uptake in ten patients. In total, 28 lymph nodes, 11 bone lesions, 3 dermal nodules, 3 pleural thickening lesions, 2 thyroid nodules, 1 pancreas, 1 liver, 1 ovary, 1 uterus, 1 breast, 1 soft tissue and 2 lung lesions were present. The best performance was observed for anatomic correlation of PET findings by the contrast-enhanced CT scans (contrast-enhanced CT, 2.64± 0.70; in-phase, 1.29±1.01; opposed-phase, 1.29±1.15; water-weighted, 1.71±1.07; fat weighted, 0.56±1.03). A significant difference was observed between the scores obtained from the contrast-enhanced CT and all four coregistered Dixon MR images. Quantitative evaluation revealed a high correlation between the SUVs measured with hybrid PET/MR (SUVmean, 2.63±1.62; SUVmax, 4.30±2.88) and contrast-enhanced PET

  12. Evaluation of Dixon Sequence on Hybrid PET/MR Compared with Contrast-Enhanced PET/CT for PET-Positive Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Ju Hye; Cho, Ihn Ho; Kong, Eun Jung; Chun, Kyung Ah [Yeungnam Univ. Hospital, Daegu (Korea, Republic of)

    2014-03-15

    Hybrid positron emission tomography and magnetic resonance (PET/MR) imaging performs a two-point Dixon MR sequence for attenuation correction. However, MR data in hybrid PET/MR should provide anatomic and morphologic information as well as an attenuation map. We evaluated the Dixon sequence of hybrid PET/MR for anatomic correlation of PET-positive lesions compared with contrast-enhanced PET/computed tomography (CT) in patients with oncologic diseases. Twelve patients underwent a single injection, dual imaging protocol. PET/CT was performed with an intravenous contrast agent (85±13 min after {sup 18}F-FDG injection of 403± 45 MBq) and then (125±19 min after injection) PET/MR was performed. Attenuation correction and anatomic allocation of PET were performed using contrast-enhanced CT for PET/CT and Dixon MR sequence for hybrid PET/MR. The Dixon MR sequence and contrast-enhanced CT were compared for anatomic correlation of PET-positive lesions (scoring scale ranging from 0 to 3 for visual ratings). Additionally, standardized uptake values (SUVs) for the detected lesions were assessed for quantitative comparison. Both hybrid PET/MR and contrast-enhanced PET/CT identified 55 lesions with increased FDG uptake in ten patients. In total, 28 lymph nodes, 11 bone lesions, 3 dermal nodules, 3 pleural thickening lesions, 2 thyroid nodules, 1 pancreas, 1 liver, 1 ovary, 1 uterus, 1 breast, 1 soft tissue and 2 lung lesions were present. The best performance was observed for anatomic correlation of PET findings by the contrast-enhanced CT scans (contrast-enhanced CT, 2.64± 0.70; in-phase, 1.29±1.01; opposed-phase, 1.29±1.15; water-weighted, 1.71±1.07; fat weighted, 0.56±1.03). A significant difference was observed between the scores obtained from the contrast-enhanced CT and all four coregistered Dixon MR images. Quantitative evaluation revealed a high correlation between the SUVs measured with hybrid PET/MR (SUVmean, 2.63±1.62; SUVmax, 4.30±2.88) and contrast

  13. Verification and validation of ACE-format library created from ENDF/B-VII.0

    International Nuclear Information System (INIS)

    Chen Chaobin; Hu Zehua; Zhang Benai; Chen Yixue; Wu Jun

    2009-01-01

    ENDF/B-VII.0, released by the USA Cross Section Evaluation Working Group(CSEWG) in December 2006, was developed in five years since the previous release of ENDF/B-VI.8 and was demonstrated to contain much better physical representations of the data and to perform much better than previus ENDF evaluations over a broad range of applications. We generated ACE-format pointwise cross section library from the ENDF/B-VII.0 neutron reaction sublibrary with the processing code NJOY. The paper provides an overview of ENDF/B-VII.0, a summary of the ACE-format files producing process and a detail description of the validation of the ACE-format library. The conclusion is that the ACE-format library produced is correct. (authors)

  14. Correction of dental artifacts within the anatomical surface in PET/MRI using active shape models and k-nearest-neighbors

    DEFF Research Database (Denmark)

    Ladefoged, Claes N.; Andersen, Flemming L.; Keller, Sune H.

    2014-01-01

    n combined PET/MR, attenuation correction (AC) is performed indirectly based on the available MR image information. Metal implant-induced susceptibility artifacts and subsequent signal voids challenge MR-based AC. Several papers acknowledge the problem in PET attenuation correction when dental...... artifacts are ignored, but none of them attempts to solve the problem. We propose a clinically feasible correction method which combines Active Shape Models (ASM) and k- Nearest-Neighbors (kNN) into a simple approach which finds and corrects the dental artifacts within the surface boundaries of the patient...... anatomy. ASM is used to locate a number of landmarks in the T1-weighted MR-image of a new patient. We calculate a vector of offsets from each voxel within a signal void to each of the landmarks. We then use kNN to classify each voxel as belonging to an artifact or an actual signal void using this offset...

  15. Angiotensinogen and ACE gene polymorphisms and risk of atrial fibrillation in the general population

    DEFF Research Database (Denmark)

    Ravn, Lasse Steen; Benn, Marianne; Nordestgaard, Børge

    2008-01-01

    Objectives The renin-angiotensin system may play a role in the pathogenesis of atrial fibrillation, and renin-angiotensin system blockers reduce the risk of atrial fibrillation. We hypothesized that polymorphisms in the angiotensinogen and angiotensin-converting enzyme (ACE) genes encoding proteins...... in this system predict risk of atrial fibrillation. Methods and results We genotyped 9235 individuals from the Danish general population, The Copenhagen City Heart Study, for the a-20c, g-6a, T174M, and M235T polymorphisms in the angiotensinogen gene and the insertion/deletion (I/D) polymorphism in the ACE gene...

  16. Association of ACE, VEGF and CCL2 gene polymorphisms with Henoch-Schönlein purpura and an evaluation of the possible interaction effects of these loci in HSP patients.

    Science.gov (United States)

    Mohammadian, Tahereh; Bonyadi, Mortaza; Nabat, Elahe; Rafeey, Mandana

    2017-07-01

    Henoch-Schönlein purpura (HSP) is a multisystem, small vessel, leucocytoclastic vasculitis. It is predominantly a childhood vasculitis, rarely reported in adults. Studies have shown that several different genetic factors such as genes involved in inflammatory system and renin-angiotensin system (RAS) are important in the pathogenesis of Henoch-Schönlein purpura. The purpose of this study was to evaluate the independent effect of 3 gene polymorphisms including CCL2-2518 C/T, VEGF-634G/C and ACE(I/D) with HSP disease and their possible joint interactions in developing the disease. In this case-control study 47 HSP cases and 74 unrelated healthy controls were enrolled for evaluation. All individuals were genotyped for CCL2-2518C/T, VEGF-634G/C and ACE(I/D) gene polymorphisms. The possible association of these polymorphisms with susceptibility to develop HSP disease independently and in different joint combinations was evaluated. The frequencies of TT genotype and T allele of CCL2-2518C/T gene polymorphism and CC genotype and C allele of VEGF-634G/C gene polymorphism were significantly high in HSP children (p-values = 0.005 and = 0.007 respectively). Interestingly, studying the joint interaction of these 2 genotypes (CC genotype of VEGF G-634C and TT genotype of CCL2 C-2518T) in this cohort showed a more significant effect in the development of the disease (p gene when combined with II genotype of ACE gene in HSP children was significantly higher (p gene-gene interaction effects of CCL2, VEGF and ACE genes in developing HSP disease.

  17. An inter-crystal scatter correction method for DOI PET image reconstruction

    International Nuclear Information System (INIS)

    Lam, Chih Fung; Hagiwara, Naoki; Obi, Takashi; Yamaguchi, Masahiro; Yamaya, Taiga; Murayama, Hideo

    2006-01-01

    New positron emission tomography (PET) scanners utilize depth-of-interaction (DOI) information to improve image resolution, particularly at the edge of field-of-view while maintaining high detector sensitivity. However, the inter-crystal scatter (ICS) effect cannot be neglected in DOI scanners due to the use of smaller crystals. ICS is the phenomenon wherein there are multiple scintillations for irradiation of a gamma photon due to Compton scatter in detecting crystals. In the case of ICS, only one scintillation position is approximated for detectors with Anger-type logic calculation. This causes an error in position detection and ICS worsens the image contrast, particularly for smaller hotspots. In this study, we propose to model an ICS probability by using a Monte Carlo simulator. The probability is given as a statistical relationship between the gamma photon first interaction crystal pair and the detected crystal pair. It is then used to improve the system matrix of a statistical image reconstruction algorithm, such as maximum likehood expectation maximization (ML-EM) in order to correct for the position error caused by ICS. We apply the proposed method to simulated data of the jPET-D4, which is a four-layer DOI PET being developed at the National Institute of Radiological Sciences. Our computer simulations show that image contrast is recovered successfully by the proposed method. (author)

  18. Effects of motion correction for dynamic [{sup 11}C]Raclopride brain PET data on the evaluation of endogenous dopamine release in striatum

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Sung; Kim, Yu Kyeong; Cho, Sang Soo; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul; Kim, Sang Eun [Seoul National University College of Medicine, Seoul (Korea, Republic of); Choe, Yearn Seong [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Kang, Eun Joo [Kangwon University, Chunchon (Korea, Republic of)

    2005-10-15

    Neuroreceptor PET studies require 60-120 minutes to complete and head motion of the subject during the PET scan increases the uncertainty in measured activity. In this study, we investigated the effects of the data-driven head motion correction on the evaluation of endogenous dopamine release (DAR) in the striatum during the motor task which might have caused significant head motion artifact. [{sup 11}C]raclopride PET scans on 4 normal volunteers acquired with bolus plus constant infusion protocol were retrospectively analyzed. Following the 50 min resting period, the participants played a video game with a momentary reward for 40 min. Dynamic frames acquired during the equilibrium condition (pre-task: 30-50 min, task: 70-90 min, post-task:110-120 min) were realigned to the first frame in pre-task condition. Intra-condition registrations between the frames were performed, and average image for each condition was created and registered to the pre-task image (inter-condition registration). Pre-task PET image was then co-registered to own MRI of each participant and transformation parameters were reapplied to the others. Volumes of interest (VOI) for dorsal putamen (PU) and caudate (CA), ventral striatum (VS), and cerebellum were defined on the MRI. Binding potential (BP) was measured and DAR was calculated as the percent change of BP during and after the task. SPM analyses on the BP parametric images were also performed to explore the regional difference in the effects of head motion on BP and DAR estimation. Changes in position and orientation of the striatum during the PET scans were observed before the head motion correction. BP values at pre-task condition were not changed significantly after the intra-condition registration. However, the BP values during and after the task and DAR were significantly changed after the correction. SPM analysis also showed that the extent and significance of the BP differences were significantly changed by the head motion

  19. Accuracy and Radiation Dose of CT-Based Attenuation Correction for Small Animal PET: A Monte Carlo Simulation Study

    International Nuclear Information System (INIS)

    Yang, Ching-Ching; Chan, Kai-Chieh

    2013-06-01

    -Small animal PET allows qualitative assessment and quantitative measurement of biochemical processes in vivo, but the accuracy and reproducibility of imaging results can be affected by several parameters. The first aim of this study was to investigate the performance of different CT-based attenuation correction strategies and assess the resulting impact on PET images. The absorbed dose in different tissues caused by scanning procedures was also discussed to minimize biologic damage generated by radiation exposure due to PET/CT scanning. A small animal PET/CT system was modeled based on Monte Carlo simulation to generate imaging results and dose distribution. Three energy mapping methods, including the bilinear scaling method, the dual-energy method and the hybrid method which combines the kVp conversion and the dual-energy method, were investigated comparatively through assessing the accuracy of estimating linear attenuation coefficient at 511 keV and the bias introduced into PET quantification results due to CT-based attenuation correction. Our results showed that the hybrid method outperformed the bilinear scaling method, while the dual-energy method achieved the highest accuracy among the three energy mapping methods. Overall, the accuracy of PET quantification results have similar trend as that for the estimation of linear attenuation coefficients, whereas the differences between the three methods are more obvious in the estimation of linear attenuation coefficients than in the PET quantification results. With regards to radiation exposure from CT, the absorbed dose ranged between 7.29-45.58 mGy for 50-kVp scan and between 6.61-39.28 mGy for 80-kVp scan. For 18 F radioactivity concentration of 1.86x10 5 Bq/ml, the PET absorbed dose was around 24 cGy for tumor with a target-to-background ratio of 8. The radiation levels for CT scans are not lethal to the animal, but concurrent use of PET in longitudinal study can increase the risk of biological effects. The

  20. ACE phenotyping in Gaucher disease.

    Science.gov (United States)

    Danilov, Sergei M; Tikhomirova, Victoria E; Metzger, Roman; Naperova, Irina A; Bukina, Tatiana M; Goker-Alpan, Ozlem; Tayebi, Nahid; Gayfullin, Nurshat M; Schwartz, David E; Samokhodskaya, Larisa M; Kost, Olga A; Sidransky, Ellen

    2018-04-01

    Gaucher disease is characterized by the activation of splenic and hepatic macrophages, accompanied by dramatically increased levels of angiotensin-converting enzyme (ACE). To evaluate the source of the elevated blood ACE, we performed complete ACE phenotyping using blood, spleen and liver samples from patients with Gaucher disease and controls. ACE phenotyping included 1) immunohistochemical staining for ACE; 2) measuring ACE activity with two substrates (HHL and ZPHL); 3) calculating the ratio of the rates of substrate hydrolysis (ZPHL/HHL ratio); 4) assessing the conformational fingerprint of ACE by evaluating the pattern of binding of monoclonal antibodies to 16 different ACE epitopes. We show that in patients with Gaucher disease, the dramatically increased levels of ACE originate from activated splenic and/or hepatic macrophages (Gaucher cells), and that both its conformational fingerprint and kinetic characteristics (ZPHL/HHL ratio) differ from controls and from patients with sarcoid granulomas. Furthermore, normal spleen was found to produce high levels of endogenous ACE inhibitors and a novel, tightly-bound 10-30 kDa ACE effector which is deficient in Gaucher spleen. The conformation of ACE is tissue-specific. In Gaucher disease, ACE produced by activated splenic macrophages differs from that in hepatic macrophages, as well as from macrophages and dendritic cells in sarcoid granulomas. The observed differences are likely due to altered ACE glycosylation or sialylation in these diseased organs. The conformational differences in ACE may serve as a specific biomarker for Gaucher disease. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Discrimination and anatomical mapping of PET-positive lesions: comparison of CT attenuation-corrected PET images with coregistered MR and CT images in the abdomen

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, Felix P.; Crook, David W.; Mader, Caecilia E.; Appenzeller, Philippe; Schulthess, G.K. von; Schmid, Daniel T. [University Hospital Zurich, Department of Medical Radiology, Zurich (Switzerland)

    2013-01-15

    PET/MR has the potential to become a powerful tool in clinical oncological imaging. The purpose of this prospective study was to evaluate the performance of a single T1-weighted (T1w) fat-suppressed unenhanced MR pulse sequence of the abdomen in comparison with unenhanced low-dose CT images to characterize PET-positive lesions. A total of 100 oncological patients underwent sequential whole-body {sup 18}F-FDG PET with CT-based attenuation correction (AC), 40 mAs low-dose CT and two-point Dixon-based T1w 3D MRI of the abdomen in a trimodality PET/CT-MR system. PET-positive lesions were assessed by CT and MRI with regard to their anatomical location, conspicuity and additional relevant information for characterization. From among 66 patients with at least one PET-positive lesion, 147 lesions were evaluated. No significant difference between MRI and CT was found regarding anatomical lesion localization. The MR pulse sequence used performed significantly better than CT regarding conspicuity of liver lesions (p < 0.001, Wilcoxon signed ranks test), whereas no difference was noted for extrahepatic lesions. For overall lesion characterization, MRI was considered superior to CT in 40 % of lesions, equal to CT in 49 %, and inferior to CT in 11 %. Fast Dixon-based T1w MRI outperformed low-dose CT in terms of conspicuity and characterization of PET-positive liver lesions and performed similarly in extrahepatic tumour manifestations. Hence, under the assumption that the technical issue of MR AC for whole-body PET examinations is solved, in abdominal PET/MR imaging the replacement of low-dose CT by a single Dixon-based MR pulse sequence for anatomical lesion correlation appears to be valid and robust. (orig.)

  2. Discrimination and anatomical mapping of PET-positive lesions: comparison of CT attenuation-corrected PET images with coregistered MR and CT images in the abdomen

    International Nuclear Information System (INIS)

    Kuhn, Felix P.; Crook, David W.; Mader, Caecilia E.; Appenzeller, Philippe; Schulthess, G.K. von; Schmid, Daniel T.

    2013-01-01

    PET/MR has the potential to become a powerful tool in clinical oncological imaging. The purpose of this prospective study was to evaluate the performance of a single T1-weighted (T1w) fat-suppressed unenhanced MR pulse sequence of the abdomen in comparison with unenhanced low-dose CT images to characterize PET-positive lesions. A total of 100 oncological patients underwent sequential whole-body 18 F-FDG PET with CT-based attenuation correction (AC), 40 mAs low-dose CT and two-point Dixon-based T1w 3D MRI of the abdomen in a trimodality PET/CT-MR system. PET-positive lesions were assessed by CT and MRI with regard to their anatomical location, conspicuity and additional relevant information for characterization. From among 66 patients with at least one PET-positive lesion, 147 lesions were evaluated. No significant difference between MRI and CT was found regarding anatomical lesion localization. The MR pulse sequence used performed significantly better than CT regarding conspicuity of liver lesions (p < 0.001, Wilcoxon signed ranks test), whereas no difference was noted for extrahepatic lesions. For overall lesion characterization, MRI was considered superior to CT in 40 % of lesions, equal to CT in 49 %, and inferior to CT in 11 %. Fast Dixon-based T1w MRI outperformed low-dose CT in terms of conspicuity and characterization of PET-positive liver lesions and performed similarly in extrahepatic tumour manifestations. Hence, under the assumption that the technical issue of MR AC for whole-body PET examinations is solved, in abdominal PET/MR imaging the replacement of low-dose CT by a single Dixon-based MR pulse sequence for anatomical lesion correlation appears to be valid and robust. (orig.)

  3. Associations of ACE Gene Insertion/Deletion Polymorphism, ACE Activity, and ACE mRNA Expression with Hypertension in a Chinese Population

    OpenAIRE

    He, Qingfang; Fan, Chunhong; Yu, Min; Wallar, Gina; Zhang, Zuo-Feng; Wang, Lixin; Zhang, Xinwei; Hu, Ruying

    2013-01-01

    Background The present study was designed to explore the association of angiotensin converting enzyme (ACE) gene insertion/deletion (I/D, rs4646994) polymorphism, plasma ACE activity, and circulating ACE mRNA expression with essential hypertension (EH) in a Chinese population. In addition, a new detection method for circulating ACE mRNA expression was explored. Methods The research was approved by the ethics committee of Zhejiang Provincial Center for Disease Prevention and Control. Written i...

  4. Impact of partial-volume correction in oncological PET studies. A systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Cysouw, Matthijs C.F.; Kramer, Gerbrand M.; Hoekstra, Otto S. [VU University Medical Centre, Department of Radiology and Nuclear Medicine, Amsterdam (Netherlands); Schoonmade, Linda J. [VU University Medical Centre, Department of Medical Library, Amsterdam (Netherlands); Boellaard, Ronald [VU University Medical Centre, Department of Radiology and Nuclear Medicine, Amsterdam (Netherlands); University Medical Centre Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); Vet, Henrica C.W. de [VU University Medical Centre, Department of Epidemiology and Biostatistics, Amsterdam (Netherlands)

    2017-11-15

    Positron-emission tomography can be useful in oncology for diagnosis, (re)staging, determining prognosis, and response assessment. However, partial-volume effects hamper accurate quantification of lesions <2-3 x the PET system's spatial resolution, and the clinical impact of this is not evident. This systematic review provides an up-to-date overview of studies investigating the impact of partial-volume correction (PVC) in oncological PET studies. We searched in PubMed and Embase databases according to the PRISMA statement, including studies from inception till May 9, 2016. Two reviewers independently screened all abstracts and eligible full-text articles and performed quality assessment according to QUADAS-2 and QUIPS criteria. For a set of similar diagnostic studies, we statistically pooled the results using bivariate meta-regression. Thirty-one studies were eligible for inclusion. Overall, study quality was good. For diagnosis and nodal staging, PVC yielded a strong trend of increased sensitivity at expense of specificity. Meta-analysis of six studies investigating diagnosis of pulmonary nodules (679 lesions) showed no significant change in diagnostic accuracy after PVC (p = 0.222). Prognostication was not improved for non-small cell lung cancer and esophageal cancer, whereas it did improve for head and neck cancer. Response assessment was not improved by PVC for (locally advanced) breast cancer or rectal cancer, and it worsened in metastatic colorectal cancer. The accumulated evidence to date does not support routine application of PVC in standard clinical PET practice. Consensus on the preferred PVC methodology in oncological PET should be reached. Partial-volume-corrected data should be used as adjuncts to, but not yet replacement for, uncorrected data. (orig.)

  5. Quantitative PET imaging with the 3T MR-BrainPET

    International Nuclear Information System (INIS)

    Weirich, C.; Scheins, J.; Lohmann, P.; Tellmann, L.; Byars, L.; Michel, C.; Rota Kops, E.; Brenner, D.; Herzog, H.; Shah, N.J.

    2013-01-01

    The new hybrid imaging technology of MR-PET allows for simultaneous acquisition of versatile MRI contrasts and the quantitative metabolic imaging with PET. In order to achieve the quantification of PET images with minimal residual error the application of several corrections is crucial. In this work we present our results on quantification with the 3T MR BrainPET scanner

  6. Association between RAS Gene Polymorphisms (ACE I/D, AGT M235T and Henoch-Schönlein Purpura in a Turkish Population

    Directory of Open Access Journals (Sweden)

    Sinem Nalbantoglu

    2013-01-01

    Full Text Available Henoch-Schönlein purpura (HSP is a small-vessel vasculitis of autoimmune hypersensitivity, and renin-angiotensin system (RAS regulates vascular homeostasis and inflammation with activation of cytokine release. Thus, we aimed to investigate the association between HSP and ACE I/D and AGT M235T polymorphisms. Genotyping was determined by allele specific PCR and PCR-RFLP. We obtained a significant difference in genotype distribution (p = 0.003 and allele frequencies (p 0.05 and allele frequencies (p > 0.05 of the AGT M235T polymorphism. Risk assessment showed significant risk for HSP in the subjects both with the ID + DD genotype (p = 0.019, OR: 2.288, 95% CI: 1.136–4.609 and D allele (OR: D vs. I: 2.0528, 95% CI: 1.3632–3.0912, p = 0.001 while no significant risk was obtained for HSP in the subjects both with the MT + TT genotype (p = 0.312, OR: 1.3905, 95% CI: 0.7326–2.6391 and T allele (OR: T vs. M: 1.065, 95% CI: 0.729–1.557, p = 0.743. Furthermore, when patients were stratified by the presence of certain systemic complications of HSP, no significant association was detected with ACE I/D, and AGT M235T polymorphisms. Our findings suggest that ACE I/D polymorphism is significantly associated with HSP susceptibility.

  7. Attenuation correction for brain PET imaging using deep neural network based on dixon and ZTE MR images.

    Science.gov (United States)

    Gong, Kuang; Yang, Jaewon; Kim, Kyungsang; El Fakhri, Georges; Seo, Youngho; Li, Quanzheng

    2018-05-23

    Positron Emission Tomography (PET) is a functional imaging modality widely used in neuroscience studies. To obtain meaningful quantitative results from PET images, attenuation correction is necessary during image reconstruction. For PET/MR hybrid systems, PET attenuation is challenging as Magnetic Resonance (MR) images do not reflect attenuation coefficients directly. To address this issue, we present deep neural network methods to derive the continuous attenuation coefficients for brain PET imaging from MR images. With only Dixon MR images as the network input, the existing U-net structure was adopted and analysis using forty patient data sets shows it is superior than other Dixon based methods. When both Dixon and zero echo time (ZTE) images are available, we have proposed a modified U-net structure, named GroupU-net, to efficiently make use of both Dixon and ZTE information through group convolution modules when the network goes deeper. Quantitative analysis based on fourteen real patient data sets demonstrates that both network approaches can perform better than the standard methods, and the proposed network structure can further reduce the PET quantification error compared to the U-net structure. © 2018 Institute of Physics and Engineering in Medicine.

  8. Motion-compensated PET image reconstruction with respiratory-matched attenuation correction using two low-dose inhale and exhale CT images

    International Nuclear Information System (INIS)

    Nam, Woo Hyun; Ahn, Il Jun; Ra, Jong Beom; Kim, Kyeong Min; Kim, Byung Il

    2013-01-01

    Positron emission tomography (PET) is widely used for diagnosis and follow up assessment of radiotherapy. However, thoracic and abdominal PET suffers from false staging and incorrect quantification of the radioactive uptake of lesion(s) due to respiratory motion. Furthermore, respiratory motion-induced mismatch between a computed tomography (CT) attenuation map and PET data often leads to significant artifacts in the reconstructed PET image. To solve these problems, we propose a unified framework for respiratory-matched attenuation correction and motion compensation of respiratory-gated PET. For the attenuation correction, the proposed algorithm manipulates a 4D CT image virtually generated from two low-dose inhale and exhale CT images, rather than a real 4D CT image which significantly increases the radiation burden on a patient. It also utilizes CT-driven motion fields for motion compensation. To realize the proposed algorithm, we propose an improved region-based approach for non-rigid registration between body CT images, and we suggest a selection scheme of 3D CT images that are respiratory-matched to each respiratory-gated sinogram. In this work, the proposed algorithm was evaluated qualitatively and quantitatively by using patient datasets including lung and/or liver lesion(s). Experimental results show that the method can provide much clearer organ boundaries and more accurate lesion information than existing algorithms by utilizing two low-dose CT images. (paper)

  9. Prediction of CT Substitutes from MR Images Based on Local Diffeomorphic Mapping for Brain PET Attenuation Correction.

    Science.gov (United States)

    Wu, Yao; Yang, Wei; Lu, Lijun; Lu, Zhentai; Zhong, Liming; Huang, Meiyan; Feng, Yanqiu; Feng, Qianjin; Chen, Wufan

    2016-10-01

    Attenuation correction is important for PET reconstruction. In PET/MR, MR intensities are not directly related to attenuation coefficients that are needed in PET imaging. The attenuation coefficient map can be derived from CT images. Therefore, prediction of CT substitutes from MR images is desired for attenuation correction in PET/MR. This study presents a patch-based method for CT prediction from MR images, generating attenuation maps for PET reconstruction. Because no global relation exists between MR and CT intensities, we propose local diffeomorphic mapping (LDM) for CT prediction. In LDM, we assume that MR and CT patches are located on 2 nonlinear manifolds, and the mapping from the MR manifold to the CT manifold approximates a diffeomorphism under a local constraint. Locality is important in LDM and is constrained by the following techniques. The first is local dictionary construction, wherein, for each patch in the testing MR image, a local search window is used to extract patches from training MR/CT pairs to construct MR and CT dictionaries. The k-nearest neighbors and an outlier detection strategy are then used to constrain the locality in MR and CT dictionaries. Second is local linear representation, wherein, local anchor embedding is used to solve MR dictionary coefficients when representing the MR testing sample. Under these local constraints, dictionary coefficients are linearly transferred from the MR manifold to the CT manifold and used to combine CT training samples to generate CT predictions. Our dataset contains 13 healthy subjects, each with T1- and T2-weighted MR and CT brain images. This method provides CT predictions with a mean absolute error of 110.1 Hounsfield units, Pearson linear correlation of 0.82, peak signal-to-noise ratio of 24.81 dB, and Dice in bone regions of 0.84 as compared with real CTs. CT substitute-based PET reconstruction has a regression slope of 1.0084 and R 2 of 0.9903 compared with real CT-based PET. In this method, no

  10. Imaging and PET - PET/CT imaging

    International Nuclear Information System (INIS)

    Von Schulthess, G.K.; Hany, Th.F.

    2008-01-01

    PET/CT has grown because the lack of anatomic landmarks in PET makes 'hardware-fusion' to anatomic cross-sectional data extremely useful. Addition of CT to PET improves specificity, but also sensitivity, and adding PET to CT adds sensitivity and specificity in tumor imaging. The synergistic advantage of adding CT is that the attenuation correction needed for PET data can also be derived from the CT data. This makes PET-CT 25-30% faster than PET alone, leading to higher patient throughput and a more comfortable examination for patients typically lasting 20 minutes or less. FDG-PET-CT appears to provide relevant information in the staging and therapy monitoring of many tumors, such as lung carcinoma, colorectal cancer, lymphoma, gynaecological cancers, melanoma and many others, with the notable exception of prostatic cancer. for this cancer, choline derivatives may possibly become useful radiopharmaceuticals. The published literature on the applications of FDG-PET-CT in oncology is still limited but several designed studies have demonstrated the benefits of PET-CT. (authors)

  11. Evaluation of transmission methodology and attenuation correction for the microPET Focus 220 animal scanner

    International Nuclear Information System (INIS)

    Lehnert, Wencke; Meikle, Steven R; Siegel, Stefan; Newport, Danny; Banati, Richard B; Rosenfeld, Anatoly B

    2006-01-01

    An accurate, low noise estimate of photon attenuation in the subject is required for quantitative microPET studies of molecular tracer distributions in vivo. In this work, several transmission-based measurement techniques were compared, including coincidence mode with and without rod windowing, singles mode with two different energy sources ( 68 Ge and 57 Co), and postinjection transmission scanning. In addition, the effectiveness of transmission segmentation and the propagation of transmission bias and noise into the emission images were examined. The 57 Co singles measurements provided the most accurate attenuation coefficients and superior signal-to-noise ratio, while 68 Ge singles measurements were degraded due to scattering from the object. Scatter correction of 68 Ge transmission data improved the accuracy for a 10 cm phantom but over-corrected for a mouse phantom. 57 Co scanning also resulted in low bias and noise in postinjection transmission scans for emission activities up to 20 MBq. Segmentation worked most reliably for transmission data acquired with 57 Co but the minor improvement in accuracy of attenuation coefficients and signal-to-noise may not justify its use, particularly for small subjects. We conclude that 57 Co singles transmission scanning is the most suitable method for measured attenuation correction on the microPET Focus 220 animal scanner

  12. A Maximum-Likelihood Method to Correct for Allelic Dropout in Microsatellite Data with No Replicate Genotypes

    Science.gov (United States)

    Wang, Chaolong; Schroeder, Kari B.; Rosenberg, Noah A.

    2012-01-01

    Allelic dropout is a commonly observed source of missing data in microsatellite genotypes, in which one or both allelic copies at a locus fail to be amplified by the polymerase chain reaction. Especially for samples with poor DNA quality, this problem causes a downward bias in estimates of observed heterozygosity and an upward bias in estimates of inbreeding, owing to mistaken classifications of heterozygotes as homozygotes when one of the two copies drops out. One general approach for avoiding allelic dropout involves repeated genotyping of homozygous loci to minimize the effects of experimental error. Existing computational alternatives often require replicate genotyping as well. These approaches, however, are costly and are suitable only when enough DNA is available for repeated genotyping. In this study, we propose a maximum-likelihood approach together with an expectation-maximization algorithm to jointly estimate allelic dropout rates and allele frequencies when only one set of nonreplicated genotypes is available. Our method considers estimates of allelic dropout caused by both sample-specific factors and locus-specific factors, and it allows for deviation from Hardy–Weinberg equilibrium owing to inbreeding. Using the estimated parameters, we correct the bias in the estimation of observed heterozygosity through the use of multiple imputations of alleles in cases where dropout might have occurred. With simulated data, we show that our method can (1) effectively reproduce patterns of missing data and heterozygosity observed in real data; (2) correctly estimate model parameters, including sample-specific dropout rates, locus-specific dropout rates, and the inbreeding coefficient; and (3) successfully correct the downward bias in estimating the observed heterozygosity. We find that our method is fairly robust to violations of model assumptions caused by population structure and by genotyping errors from sources other than allelic dropout. Because the data sets

  13. Angiotensin-converting enzyme activity in Cavalier King Charles Spaniels with an ACE gene polymorphism and myxomatous mitral valve disease.

    Science.gov (United States)

    Meurs, Kathryn M; Olsen, Lisbeth H; Reimann, Maria J; Keene, Bruce W; Atkins, Clarke E; Adin, Darcy; Aona, Brent; Condit, Julia; DeFrancesco, Teresa; Reina-Doreste, Yamir; Stern, Joshua A; Tou, Sandra; Ward, Jessica; Woodruff, Kathleen

    2018-02-01

    Myxomatous mitral valve disease (MMVD) is the most common heart disease in the dog. It is particularly common in the Cavalier King Charles Spaniel (CKCS) breed and affected dogs are frequently managed with angiotensin-converting enzyme inhibitors (ACE-I). We have previously identified a canine ACE gene polymorphism associated with a decrease in angiotensin-converting enzyme (ACE) activity. The aim of this study was to evaluate for the prevalence of the ACE polymorphism in CKCS with mitral valve disease and to determine whether the presence of the polymorphism is associated with alterations in ACE activity at different stages of cardiac disease. Seventy-three dogs with a diagnosis of mitral valve disease were evaluated and a blood sample was drawn for ACE polymorphism genotyping and ACE activity measurement. Forty-three dogs were homozygous for the ACE polymorphism; five were heterozygous and 25 were homozygous wild type. The mean age and the median severity of disease were not different for dogs with the polymorphism and dogs with the wild-type sequence. The median baseline ACE activity was significantly lower for the ACE polymorphism (27.0 U/l) than the wild-type sequence dogs (31.0 U/l) (P=0.02). Dogs with more severe disease and the ACE polymorphism had significantly lower levels of ACE activity than dogs with the wild-type sequence (P=0.03). The CKCS appears to have a high prevalence of the ACE variant. Dogs with the ACE variant had lower levels of ACE activity even in more advanced mitral valve disease than dogs without the variant. The clinical significance of this finding and its impact on the need for ACE-I in dogs with the polymorphism and heart disease deserves further study.

  14. Effect of ACE insertion/deletion and 12 other polymorphisms on clinical outcomes and response to treatment in the life study

    DEFF Research Database (Denmark)

    Nordestgaard, Børge G; Kontula, Kimmo; Benn, Marianne

    2010-01-01

    OBJECTIVE: This pharmacogenetics substudy from the Losartan Intervention for Endpoint reduction in Hypertension study in patients with hypertension and left ventricular hypertrophy (LVH) treated with the angiotensin receptor blocker losartan versus the beta-blocker atenolol for 4.8 years tested...... whether the insertion/deletion (I/D) polymorphism of the angiotensin-converting enzyme (ACE) gene and 12 other previously well-characterized polymorphisms of hypertension susceptibility genes affected blood pressure reduction, heart rate reduction, cardiovascular events, and/or response to treatment....... These polymorphisms were chosen because they could affect blood pressure control or the pharmacological action of losartan or atenolol. METHODS: We genotyped 3503 patients, 1774 on losartan and 1729 on atenolol. RESULTS: ACE and the 12 other genotypes did not affect the reduction in systolic blood pressure, diastolic...

  15. Insertion/deletion polymorphism of the ACE gene and adherence to ACE inhibitors

    NARCIS (Netherlands)

    H. Schelleman (Hedi); O.H. Klungel (Olaf); C.M. van Duijn (Cornelia); J.C.M. Witteman (Jacqueline); A. Hofman (Albert); A.C. de Boer (Anton); B.H.Ch. Stricker (Bruno)

    2005-01-01

    textabstractAims: We investigated whether the insertion/deletion (I/D) polymorphism of the ACE gene modified the adherence to ACE inhibitors as measured by the discontinuation of an ACE inhibitor, or addition of another antihypertensive drug. Methods: This was a cohort study among 239 subjects who

  16. Description and assessment of a registration-based approach to include bones for attenuation correction of whole-body PET/MRI.

    Science.gov (United States)

    Marshall, Harry R; Patrick, John; Laidley, David; Prato, Frank S; Butler, John; Théberge, Jean; Thompson, R Terry; Stodilka, Robert Z

    2013-08-01

    Attenuation correction for whole-body PET/MRI is challenging. Most commercial systems compute the attenuation map from MRI using a four-tissue segmentation approach. Bones, the most electron-dense tissue, are neglected because they are difficult to segment. In this work, the authors build on this segmentation approach by adding bones using a registration technique and assessing its performance on human PET images. Twelve oncology patients were imaged with FDG PET/CT and MRI using a Turbo-FLASH pulse sequence. A database of 121 attenuation correction quality CT scans was also collected. Each patient MRI was compared to the CT database via weighted heuristic measures to find the "most similar" CT in terms of body geometry. The similar CT was aligned to the MRI with a deformable registration method. Two MRI-based attenuation maps were computed. One was a standard four-tissue segmentation (air, lung, fat, and lean tissue) using basic image processing techniques. The other was identical, except the bones from the aligned CT were added. The PET data were reconstructed with the patient's CT-based attenuation map (the silver standard) and both MRI-based attenuation maps. The relative errors of the MRI-based attenuation corrections were computed in 14 standardized volumes of interest, in lesions, and over whole tissues. The squared Pearson correlation coefficient was also calculated over whole tissues. Statistical testing was done with ANOVAs and paired t-tests. The MRI-based attenuation correction ignoring bone had relative errors ranging from -37% to -8% in volumes of interest containing bone. By including bone, the magnitude of the relative error was reduced in all cases (pbone was improved from a mean of -7.5% to 2% (pbone reduced the magnitude of relative error in three cases (pbone slightly increased relative error in lung from 7.7% to 8.0% (p=0.002), in fat from 8.5% to 9.2% (pbone from -14.6% to 1.3% (pbone was included or not. The approach to include bones in MRI

  17. Analysis of Polymorphism of Angiotensin System Genes (ACE, AGTR1, and AGT) and Gene ITGB3 in Patients with Arterial Hypertension in Combination with Metabolic Syndrome.

    Science.gov (United States)

    Zotova, T Yu; Kubanova, A P; Azova, M M; Aissa, A Ait; Gigani, O O; Frolov, V A

    2016-07-01

    Changes in the frequencies of genotypes and mutant alleles of ACE, AGTR1, AGT, and ITGB3 genes were analyzed in patients with arterial hypertension coupled with metabolic syndrome (N=15) and compared with population data and corresponding parameters in patients with isolated hypertension (N=15). Increased frequency of genotype ID of ACE gene (hypertension predictor) was confirmed for both groups. In case of isolated hypertension, M235M genotype (gene AGT) was more frequent, in case of hypertension combined with metabolic syndrome, the frequency of genotypes A1166C and C1166C of the gene AGTR1 was higher in comparison with population data. Comparison of mutant allele frequencies in the two groups showed that at the 90% significance level allele T of the AGT gene was more frequent in hypertension coupled with metabolic syndrome (OR=1.26) and genotype A1166A of the AGTR1 gene was more frequent in the group with isolated hypertension.

  18. Methods for the correction of vascular artifacts in PET O-15 water brain-mapping studies

    Science.gov (United States)

    Chen, Kewei; Reiman, E. M.; Lawson, M.; Yun, Lang-sheng; Bandy, D.; Palant, A.

    1996-12-01

    While positron emission tomographic (PET) measurements of regional cerebral blood flow (rCBF) can be used to map brain regions that are involved in normal and pathological human behaviors, measurements in the anteromedial temporal lobe can be confounded by the combined effects of radiotracer activity in neighboring arteries and partial-volume averaging. The authors now describe two simple methods to address this vascular artifact. One method utilizes the early frames of a dynamic PET study, while the other method utilizes a coregistered magnetic resonance image (MRI) to characterize the vascular region of interest (VROI). Both methods subsequently assign a common value to each pixel in the VROI for the control (baseline) scan and the activation scan. To study the vascular artifact and to demonstrate the ability of the proposed methods correcting the vascular artifact, four dynamic PET scans were performed in a single subject during the same behavioral state. For each of the four scans, a vascular scan containing vascular activity was computed as the summation of the images acquired 0-60 s after radiotracer administration, and a control scan containing minimal vascular activity was computed as the summation of the images acquired 20-80 s after radiotracer administration. t-score maps calculated from the four pairs of vascular and control scans were used to characterize regional blood flow differences related to vascular activity before and after the application of each vascular artifact correction method. Both methods eliminated the observed differences in vascular activity, as well as the vascular artifact observed in the anteromedial temporal lobes. Using PET data from a study of normal human emotion, these methods permitted the authors to identify rCBF increases in the anteromedial temporal lobe free from the potentially confounding, combined effects of vascular activity and partial-volume averaging.

  19. Methods for the correction of vascular artifacts in PET O-15 water brain-mapping studies

    International Nuclear Information System (INIS)

    Chen, K.; Reiman, E.M.; Good Samaritan Regional Medical Center, Phoenix, AZ; Lawson, M.; Yun, L.S.; Bandy, D.

    1996-01-01

    While positron emission tomographic (PET) measurements of regional cerebral blood flow (rCBF) can be used to map brain regions that are involved in normal and pathological human behaviors, measurements in the anteromedial temporal lobe can be confounded by the combined effects of radiotracer activity in neighboring arteries and partial-volume averaging. The authors now describe two simple methods to address this vascular artifact. One method utilizes the early frames of a dynamic PET study, while the other method utilizes a coregistered magnetic resonance image (MRI) to characterize the vascular region of interest (VROI). Both methods subsequently assign a common value to each pixel in the VROI for the control scan and the activation scan. To study the vascular artifact and to demonstrate the ability of the proposed methods correcting the vascular artifact, four dynamic PET scans were performed in a single subject during the same behavioral state. For each of the four scans, a vascular scan containing vascular activity was computed as the summation of the images acquired 0--60 s after radiotracer administrations, and a control scan containing minimal vascular activity was computed as the summation of the images acquired 20--80 s after radiotracer administration. t-score maps calculated from the four pairs of vascular and control scans were used to characterize regional blood flow differences related to vascular activity before and after the applications of each vascular artifact correction method. Both methods eliminated the observed differences in vascular activity, as well as the vascular artifact observed in the anteromedial temporal lobes. Using PET data from a study of normal human emotion, these methods permitted us to identify rCBF increases in the anteromedial temporal lobe free from the potentially confounding, combined effects of vascular activity and partial-volume averaging

  20. [Association of I/D and -786 Polymorphisms of ACE and NOS3 Genes With Features of the Course of Ischemic Heart Disease and Diabetes Mellitus Type 2].

    Science.gov (United States)

    Afanasiev, S A; Muslimova, E F; Rebrov, T Y; Sergienko, T N; Repin, A N

    2016-09-01

    to study relationship of ACE insertion-deletion (I/D) polymorphism and NOS3 T-786C polymorphism with characteristics of the course of ischemic heart disease (IHD) at the background of diabetes mellitus. Were examined 114 patients with IHD, 29.8% of patients had type 2 diabetes mellitus. ACE and NOS3 polymorphisms were determined by allele-specific polymerase chain reaction with primers by "Lytech". Patients with combined pathology belonged to older age group, had increased frequency of obesity and predominance of functional class II chronic heart failure. In this group we detected association of D allele of the ACE gene with higher frequency of dyslipidemia and obesity. Among patients with IHD without diabetes we observed associations of ACE I/D and NOS3 T-786C polymorphisms (close and moderate, respectively) with severity of effort angina. We also found that frequency of dyslipidemia among carriers of II and TT genotypes was lower than among carriers of other genotypes. Presence of type 2 diabetes as background pathology leads to a change of character of association of ACE I/D and NOS3 T-786C polymorphisms with clinical characteristics of patients with IHD.

  1. Evaluation of respiratory and cardiac motion correction schemes in dual gated PET/CT cardiac imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lamare, F., E-mail: frederic.lamare@chu-bordeaux.fr; Fernandez, P. [Univ. Bordeaux, INCIA, UMR 5287, F-33400 Talence (France); CNRS, INCIA, UMR 5287, F-33400 Talence (France); Service de Médecine Nucléaire, Hôpital Pellegrin, CHU de Bordeaux, 33076 Bordeaux (France); Le Maitre, A.; Visvikis, D. [INSERM, UMR1101, LaTIM, Université de Bretagne Occidentale, 29609 Brest (France); Dawood, M.; Schäfers, K. P. [European Institute for Molecular Imaging, University of Münster, Mendelstr. 11, 48149 Münster (Germany); Rimoldi, O. E. [Vita-Salute University and Scientific Institute San Raffaele, Milan, Italy and CNR Istituto di Bioimmagini e Fisiologia Molecolare, Milan (Italy)

    2014-07-15

    Purpose: Cardiac imaging suffers from both respiratory and cardiac motion. One of the proposed solutions involves double gated acquisitions. Although such an approach may lead to both respiratory and cardiac motion compensation there are issues associated with (a) the combination of data from cardiac and respiratory motion bins, and (b) poor statistical quality images as a result of using only part of the acquired data. The main objective of this work was to evaluate different schemes of combining binned data in order to identify the best strategy to reconstruct motion free cardiac images from dual gated positron emission tomography (PET) acquisitions. Methods: A digital phantom study as well as seven human studies were used in this evaluation. PET data were acquired in list mode (LM). A real-time position management system and an electrocardiogram device were used to provide the respiratory and cardiac motion triggers registered within the LM file. Acquired data were subsequently binned considering four and six cardiac gates, or the diastole only in combination with eight respiratory amplitude gates. PET images were corrected for attenuation, but no randoms nor scatter corrections were included. Reconstructed images from each of the bins considered above were subsequently used in combination with an affine or an elastic registration algorithm to derive transformation parameters allowing the combination of all acquired data in a particular position in the cardiac and respiratory cycles. Images were assessed in terms of signal-to-noise ratio (SNR), contrast, image profile, coefficient-of-variation (COV), and relative difference of the recovered activity concentration. Results: Regardless of the considered motion compensation strategy, the nonrigid motion model performed better than the affine model, leading to higher SNR and contrast combined with a lower COV. Nevertheless, when compensating for respiration only, no statistically significant differences were

  2. Expression and evolutionary analyses of three acetylcholinesterase genes (Mi-ace-1, Mi-ace-2, Mi-ace-3) in the root-knot nematode Meloidogyne incognita.

    Science.gov (United States)

    Cui, Ruqiang; Zhang, Lei; Chen, Yuyan; Huang, Wenkun; Fan, Chengming; Wu, Qingsong; Peng, Deliang; da Silva, Washington; Sun, Xiaotang

    2017-05-01

    The full cDNA of Mi-ace-3 encoding an acetylcholinesterase (AChE) in Meloidogyne incognita was cloned and characterized. Mi-ace-3 had an open reading frame of 1875 bp encoding 624 amino acid residues. Key residues essential to AChE structure and function were conserved. The deduced Mi-ACE-3 protein sequence had 72% amino acid similarity with that of Ditylenchus destructor Dd-AChE-3. Phylogenetic analyses using 41 AChEs from 24 species showed that Mi-ACE-3 formed a cluster with 4 other nematode AChEs. Our results revealed that the Mi-ace-3 cloned in this study, which is orthologous to Caenorhabditis elegans AChE, belongs to the nematode ACE-3/4 subgroup. There was a significant reduction in the number of galls in transgenic tobacco roots when Mi-ace-1, Mi-ace-2, and Mi-ace-3 were knocked down simultaneously, whereas little or no effect were observed when only one or two of these genes were knocked down. This is an indication that the functions of these three genes are redundant. Copyright © 2017. Published by Elsevier Inc.

  3. ACE-2/Ang1-7/Mas cascade mediates ACE inhibitor, captopril, protective effects in estrogen-deficient osteoporotic rats.

    Science.gov (United States)

    Abuohashish, Hatem M; Ahmed, Mohammed M; Sabry, Dina; Khattab, Mahmoud M; Al-Rejaie, Salim S

    2017-08-01

    The local role of the renin angiotensin system (RAS) was documented recently beside its conventional systemic functions. Studies showed that the effector angiotensin II (AngII) alters bone health, while inhibition of the angiotensin converting enzyme (ACE-1) preserved these effects. The newly identified Ang1-7 exerts numerous beneficial effects opposing the AngII. Thus, the current study examines the role of Ang1-7 in mediating the osteo-preservative effects of ACEI (captopril) through the G-protein coupled Mas receptor using an ovariectomized (OVX) rat model of osteoporosis. 8 weeks after the surgical procedures, captopril was administered orally (40mgkg -1 d -1 ), while the specific Mas receptor blocker (A-779) was delivered at infusion rate of 400ngkg -1 min -1 for 6 weeks. Bone metabolic markers were measured in serum and urine. Minerals concentrations were quantified in serum, urine and femoral bones by inductive coupled plasma mass spectroscopy (ICP-MS). Trabecular and cortical morphometry was analyzed in the right distal femurs using micro-CT. Finally, the expressions of RAS peptides, enzymes and receptors along with the receptor activator of NF-κB ligand (RANKL) and osteoprotegerin (OPG) were determined femurs heads. OVX animals markedly showed altered bone metabolism and mineralization along with disturbed bone micro-structure. Captopril significantly restored the metabolic bone bio-markers and corrected Ca 2+ and P values in urine and bones of estrogen deficient rats. Moreover, the trabecular and cortical morphometric features were repaired by captopril in OVX groups. Captopril also improved the expressions of ACE-2, Ang1-7, Mas and OPG, while abolished OVX-induced up-regulation of ACE-1, AngII, Ang type 1 receptor (AT1R) and RANKL. Inhibition of Ang1-7 cascade by A-779 significantly eradicated captopril protective effects on bone metabolism, mineralization and micro-structure. A-779 also restored OVX effects on RANKL expression and ACE-1/AngII/AT1R

  4. Staging performance of whole-body DWI, PET/CT and PET/MRI in invasive ductal carcinoma of the breast.

    Science.gov (United States)

    Catalano, Onofrio Antonio; Daye, Dania; Signore, Alberto; Iannace, Carlo; Vangel, Mark; Luongo, Angelo; Catalano, Marco; Filomena, Mazzeo; Mansi, Luigi; Soricelli, Andrea; Salvatore, Marco; Fuin, Niccolo; Catana, Ciprian; Mahmood, Umar; Rosen, Bruce Robert

    2017-07-01

    The aim of the present study was to evaluate the performance of whole-body diffusion-weighted imaging (WB-DWI), whole-body positron emission tomography with computed tomography (WB-PET/CT), and whole-body positron emission tomography with magnetic resonance imaging (WB-PET/MRI) in staging patients with untreated invasive ductal carcinoma of the breast. Fifty-one women with newly diagnosed invasive ductal carcinoma of the breast underwent WB-DWI, WB-PET/CT and WB-PET/MRI before treatment. A radiologist and a nuclear medicine physician reviewed in consensus the images from the three modalities and searched for occurrence, number and location of metastases. Final staging, according to each technique, was compared. Pathology and imaging follow-up were used as the reference. WB-DWI, WB-PET/CT and WB-PET/MRI correctly and concordantly staged 33/51 patients: stage IIA in 7 patients, stage IIB in 8 patients, stage IIIC in 4 patients and stage IV in 14 patients. WB-DWI, WB-PET/CT and WB-PET/MRI incorrectly and concordantly staged 1/51 patient as stage IV instead of IIIA. Discordant staging was reported in 17/51 patients. WB-PET/MRI resulted in improved staging when compared to WB-PET/CT (50 correctly staged on WB-PET/MRI vs. 38 correctly staged on WB-PET/CT; McNemar's test; p<0.01). Comparing the performance of WB-PET/MRI and WB-DWI (43 correct) did not reveal a statistically significant difference (McNemar test, p=0.14). WB-PET/MRI is more accurate in the initial staging of breast cancer than WB-DWI and WB-PET/CT, however, the discrepancies between WB-PET/MRI and WB-DWI were not statistically significant. When available, WB-PET/MRI should be considered for staging patient with invasive ductal breast carcinoma.

  5. Attenuation correction for the HRRT PET-scanner using transmission scatter correction and total variation regularization.

    Science.gov (United States)

    Keller, Sune H; Svarer, Claus; Sibomana, Merence

    2013-09-01

    In the standard software for the Siemens high-resolution research tomograph (HRRT) positron emission tomography (PET) scanner the most commonly used segmentation in the μ -map reconstruction for human brain scans is maximum a posteriori for transmission (MAP-TR). Bias in the lower cerebellum and pons in HRRT brain images have been reported. The two main sources of the problem with MAP-TR are poor bone/soft tissue segmentation below the brain and overestimation of bone mass in the skull. We developed the new transmission processing with total variation (TXTV) method that introduces scatter correction in the μ-map reconstruction and total variation filtering to the transmission processing. Comparing MAP-TR and the new TXTV with gold standard CT-based attenuation correction, we found that TXTV has less bias as compared to MAP-TR. We also compared images acquired at the HRRT scanner using TXTV to the GE Advance scanner images and found high quantitative correspondence. TXTV has been used to reconstruct more than 4000 HRRT scans at seven different sites with no reports of biases. TXTV-based reconstruction is recommended for human brain scans on the HRRT.

  6. Ultralow dose computed tomography attenuation correction for pediatric PET CT using adaptive statistical iterative reconstruction

    International Nuclear Information System (INIS)

    Brady, Samuel L.; Shulkin, Barry L.

    2015-01-01

    Purpose: To develop ultralow dose computed tomography (CT) attenuation correction (CTAC) acquisition protocols for pediatric positron emission tomography CT (PET CT). Methods: A GE Discovery 690 PET CT hybrid scanner was used to investigate the change to quantitative PET and CT measurements when operated at ultralow doses (10–35 mA s). CT quantitation: noise, low-contrast resolution, and CT numbers for 11 tissue substitutes were analyzed in-phantom. CT quantitation was analyzed to a reduction of 90% volume computed tomography dose index (0.39/3.64; mGy) from baseline. To minimize noise infiltration, 100% adaptive statistical iterative reconstruction (ASiR) was used for CT reconstruction. PET images were reconstructed with the lower-dose CTAC iterations and analyzed for: maximum body weight standardized uptake value (SUV bw ) of various diameter targets (range 8–37 mm), background uniformity, and spatial resolution. Radiation dose and CTAC noise magnitude were compared for 140 patient examinations (76 post-ASiR implementation) to determine relative dose reduction and noise control. Results: CT numbers were constant to within 10% from the nondose reduced CTAC image for 90% dose reduction. No change in SUV bw , background percent uniformity, or spatial resolution for PET images reconstructed with CTAC protocols was found down to 90% dose reduction. Patient population effective dose analysis demonstrated relative CTAC dose reductions between 62% and 86% (3.2/8.3–0.9/6.2). Noise magnitude in dose-reduced patient images increased but was not statistically different from predose-reduced patient images. Conclusions: Using ASiR allowed for aggressive reduction in CT dose with no change in PET reconstructed images while maintaining sufficient image quality for colocalization of hybrid CT anatomy and PET radioisotope uptake

  7. Ultralow dose computed tomography attenuation correction for pediatric PET CT using adaptive statistical iterative reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Brady, Samuel L., E-mail: samuel.brady@stjude.org [Division of Diagnostic Imaging, St. Jude Children’s Research Hospital, Memphis, Tennessee 38105 (United States); Shulkin, Barry L. [Nuclear Medicine and Department of Radiological Sciences, St. Jude Children’s Research Hospital, Memphis, Tennessee 38105 (United States)

    2015-02-15

    Purpose: To develop ultralow dose computed tomography (CT) attenuation correction (CTAC) acquisition protocols for pediatric positron emission tomography CT (PET CT). Methods: A GE Discovery 690 PET CT hybrid scanner was used to investigate the change to quantitative PET and CT measurements when operated at ultralow doses (10–35 mA s). CT quantitation: noise, low-contrast resolution, and CT numbers for 11 tissue substitutes were analyzed in-phantom. CT quantitation was analyzed to a reduction of 90% volume computed tomography dose index (0.39/3.64; mGy) from baseline. To minimize noise infiltration, 100% adaptive statistical iterative reconstruction (ASiR) was used for CT reconstruction. PET images were reconstructed with the lower-dose CTAC iterations and analyzed for: maximum body weight standardized uptake value (SUV{sub bw}) of various diameter targets (range 8–37 mm), background uniformity, and spatial resolution. Radiation dose and CTAC noise magnitude were compared for 140 patient examinations (76 post-ASiR implementation) to determine relative dose reduction and noise control. Results: CT numbers were constant to within 10% from the nondose reduced CTAC image for 90% dose reduction. No change in SUV{sub bw}, background percent uniformity, or spatial resolution for PET images reconstructed with CTAC protocols was found down to 90% dose reduction. Patient population effective dose analysis demonstrated relative CTAC dose reductions between 62% and 86% (3.2/8.3–0.9/6.2). Noise magnitude in dose-reduced patient images increased but was not statistically different from predose-reduced patient images. Conclusions: Using ASiR allowed for aggressive reduction in CT dose with no change in PET reconstructed images while maintaining sufficient image quality for colocalization of hybrid CT anatomy and PET radioisotope uptake.

  8. Metabolic impact of partial volume correction of [18F]FDG PET-CT oncological studies on the assessment of tumor response to treatment.

    Science.gov (United States)

    Stefano, A; Gallivanone, F; Messa, C; Gilardi, M C; Gastiglioni, I

    2014-12-01

    The aim of this work is to evaluate the metabolic impact of Partial Volume Correction (PVC) on the measurement of the Standard Uptake Value (SUV) from [18F]FDG PET-CT oncological studies for treatment monitoring purpose. Twenty-nine breast cancer patients with bone lesions (42 lesions in total) underwent [18F]FDG PET-CT studies after surgical resection of breast cancer primitives, and before (PET-II) chemotherapy and hormone treatment. PVC of bone lesion uptake was performed on the two [18F]FDG PET-CT studies, using a method based on Recovery Coefficients (RC) and on an automatic measurement of lesion metabolic volume. Body-weight average SUV was calculated for each lesion, with and without PVC. The accuracy, reproducibility, clinical feasibility and the metabolic impact on treatment response of the considered PVC method was evaluated. The PVC method was found clinically feasible in bone lesions, with an accuracy of 93% for lesion sphere-equivalent diameter >1 cm. Applying PVC, average SUV values increased, from 7% up to 154% considering both PET-I and PET-II studies, proving the need of the correction. As main finding, PVC modified the therapy response classification in 6 cases according to EORTC 1999 classification and in 5 cases according to PERCIST 1.0 classification. PVC has an important metabolic impact on the assessment of tumor response to treatment by [18F]FDG PET-CT oncological studies.

  9. The ACE Gene Is Associated with Late-Life Major Depression and Age at Dementia Onset in a Population-Based Cohort.

    Science.gov (United States)

    Zettergren, Anna; Kern, Silke; Gustafson, Deborah; Gudmundsson, Pia; Sigström, Robert; Östling, Svante; Eriksson, Elias; Zetterberg, Henrik; Blennow, Kaj; Skoog, Ingmar

    2017-02-01

    Depression and dementia in the elderly have been suggested to share similar risk factors and pathogenetic background, and recently the authors reported that the APOEɛ4 allele is a risk factor for both disorders in the general population. The aim of the present study was to examine the influence of the well-known polymorphisms rs1799752 in the angiotensin-converting enzyme (ACE) and rs5186 in the angiotensin receptor II type 1 (AGTR1) on late-life depression and dementia in a population-based Swedish cohort of older individuals followed over 12 years. In 2000-2001, 900 individuals underwent neuropsychiatric and neuropsychological examinations. Follow-up evaluations were performed in 2005-2006 and 2009-2010, and register data on dementia to 2012 were included. Cross-sectional associations between genotypes/alleles and depression and dementia at baseline and between genotypes/alleles and depression on at least one occasion during the study period and dementia onset to 2012 were investigated. As previously found for rs1799752 in ACE, rs5186 in AGTR1 was associated with dementia at baseline (OR: 3.25 [CI: 1.42-7.06], z = 2.90, p = 0.004). These associations became substantially weaker, or disappeared, when dementia onset to 2012 was included. For rs1799752 this could be explained by a significant association with age at onset (mean: 79.5 [SD: 6.45] years for risk-genotype carriers and 81.7 [SD: 7.12] years for carriers of other genotypes, b = -2.43, t = -2.38, df = 192, p = 0.02). When individuals with major depression on at least one occasion were analyzed, a significant association (OR: 2.14 [95% CI: 1.13-4.20], z = 2.28, p = 0.02), remaining after exclusion of dementia, with rs1799752 in ACE was found. In this population-based sample of older individuals, genetic variations in ACE seem to be important both for late-life major depression and dementia. Copyright © 2017 American Association for Geriatric Psychiatry. Published by

  10. Prediction of severe hypoglycaemia by angiotensin-converting enzyme activity and genotype in type 1 diabetes

    DEFF Research Database (Denmark)

    Pedersen-Bjerggaard, U.; Agerholm-Larsen, B.; Pramming, S.

    2003-01-01

    AIMS/HYPOTHESIS: We have previously shown a strong relationship between high angiotensin-converting enzyme (ACE) activity, presence of the deletion (D) allele of the ACEgene and recall of severe hypoglycaemic events in patients with Type 1 diabetes. This study was carried out to assess...... this relationship prospectively. METHODS: We followed 171 adult outpatients with Type 1 diabetes in a one-year observational study with the recording of severe hypoglycaemia. Participants were characterised by serum ACE activity and ACE genotype and not treated with ACE inhibitors or angiotensin II receptor...... antagonists. RESULTS: There was a positive relationship between serum ACE activity and rate of severe hypoglycaemia with a 2.7 times higher rate in the fourth quartile of ACE activity compared to the first quartile (p=0.0007). A similar relationship was observed for the subset of episodes with coma (2.9 times...

  11. A Time-Walk Correction Method for PET Detectors Based on Leading Edge Discriminators.

    Science.gov (United States)

    Du, Junwei; Schmall, Jeffrey P; Judenhofer, Martin S; Di, Kun; Yang, Yongfeng; Cherry, Simon R

    2017-09-01

    The leading edge timing pick-off technique is the simplest timing extraction method for PET detectors. Due to the inherent time-walk of the leading edge technique, corrections should be made to improve timing resolution, especially for time-of-flight PET. Time-walk correction can be done by utilizing the relationship between the threshold crossing time and the event energy on an event by event basis. In this paper, a time-walk correction method is proposed and evaluated using timing information from two identical detectors both using leading edge discriminators. This differs from other techniques that use an external dedicated reference detector, such as a fast PMT-based detector using constant fraction techniques to pick-off timing information. In our proposed method, one detector was used as reference detector to correct the time-walk of the other detector. Time-walk in the reference detector was minimized by using events within a small energy window (508.5 - 513.5 keV). To validate this method, a coincidence detector pair was assembled using two SensL MicroFB SiPMs and two 2.5 mm × 2.5 mm × 20 mm polished LYSO crystals. Coincidence timing resolutions using different time pick-off techniques were obtained at a bias voltage of 27.5 V and a fixed temperature of 20 °C. The coincidence timing resolution without time-walk correction were 389.0 ± 12.0 ps (425 -650 keV energy window) and 670.2 ± 16.2 ps (250-750 keV energy window). The timing resolution with time-walk correction improved to 367.3 ± 0.5 ps (425 - 650 keV) and 413.7 ± 0.9 ps (250 - 750 keV). For comparison, timing resolutions were 442.8 ± 12.8 ps (425 - 650 keV) and 476.0 ± 13.0 ps (250 - 750 keV) using constant fraction techniques, and 367.3 ± 0.4 ps (425 - 650 keV) and 413.4 ± 0.9 ps (250 - 750 keV) using a reference detector based on the constant fraction technique. These results show that the proposed leading edge based time-walk correction method works well. Timing resolution obtained

  12. SU-E-QI-03: Compartment Modeling of Dynamic Brain PET - The Effect of Scatter and Random Corrections On Parameter Errors

    International Nuclear Information System (INIS)

    Häggström, I; Karlsson, M; Larsson, A; Schmidtlein, C

    2014-01-01

    Purpose: To investigate the effects of corrections for random and scattered coincidences on kinetic parameters in brain tumors, by using ten Monte Carlo (MC) simulated dynamic FLT-PET brain scans. Methods: The GATE MC software was used to simulate ten repetitions of a 1 hour dynamic FLT-PET scan of a voxelized head phantom. The phantom comprised six normal head tissues, plus inserted regions for blood and tumor tissue. Different time-activity-curves (TACs) for all eight tissue types were used in the simulation and were generated in Matlab using a 2-tissue model with preset parameter values (K1,k2,k3,k4,Va,Ki). The PET data was reconstructed into 28 frames by both ordered-subset expectation maximization (OSEM) and 3D filtered back-projection (3DFBP). Five image sets were reconstructed, all with normalization and different additional corrections C (A=attenuation, R=random, S=scatter): Trues (AC), trues+randoms (ARC), trues+scatters (ASC), total counts (ARSC) and total counts (AC). Corrections for randoms and scatters were based on real random and scatter sinograms that were back-projected, blurred and then forward projected and scaled to match the real counts. Weighted non-linearleast- squares fitting of TACs from the blood and tumor regions was used to obtain parameter estimates. Results: The bias was not significantly different for trues (AC), trues+randoms (ARC), trues+scatters (ASC) and total counts (ARSC) for either 3DFBP or OSEM (p<0.05). Total counts with only AC stood out however, with an up to 160% larger bias. In general, there was no difference in bias found between 3DFBP and OSEM, except in parameter Va and Ki. Conclusion: According to our results, the methodology of correcting the PET data for randoms and scatters performed well for the dynamic images where frames have much lower counts compared to static images. Generally, no bias was introduced by the corrections and their importance was emphasized since omitting them increased bias extensively

  13. Identification and characterisation of the angiotensin converting enzyme-3 (ACE3) gene: a novel mammalian homologue of ACE

    OpenAIRE

    Rella, Monika; Elliot, Joann L; Revett, Timothy J; Lanfear, Jerry; Phelan, Anne; Jackson, Richard M; Turner, Anthony J; Hooper, Nigel M

    2007-01-01

    Abstract Background Mammalian angiotensin converting enzyme (ACE) plays a key role in blood pressure regulation. Although multiple ACE-like proteins exist in non-mammalian organisms, to date only one other ACE homologue, ACE2, has been identified in mammals. Results Here we report the identification and characterisation of the gene encoding a third homologue of ACE, termed ACE3, in several mammalian genomes. The ACE3 gene is located on the same chromosome downstream of the ACE gene. Multiple ...

  14. Response to angiotensin-converting enzyme inhibition is selectively blunted by high sodium in angiotensin-converting enzyme DD genotype: evidence for gene-environment interaction in healthy volunteers.

    Science.gov (United States)

    Lely, A Titia; Heerspink, Hiddo J Lambers; Zuurman, Mike; Visser, Folkert W; Kocks, Menno J A; Boomsma, Frans; Navis, Gerjan

    2010-12-01

    Renin-angiotensin-aldosterone system blockade is a cornerstone in cardiovascular protection. Angiotensin-converting enzyme (ACE)-DD genotype has been associated with resistance to angiotensin-converting enzyme inhibition (ACEi), but data are conflicting. As sodium intake modifies the effect of ACEi as well as the genotype-phenotype relationship, we hypothesize gene-environment interaction between sodium-status, the response to ACEi, and ACE genotype. Thirty-five male volunteers (26 ± 9 years; II n = 6, ID n = 18, DD n = 11) were studied during placebo and ACEi (double blind, enalapril 20 mg/day) on low [7 days 50 mmol Na/day (low salt)] and high [7 days 200 mmol Na/day (high salt)] sodium, with a washout of 6 weeks in-between. After each period mean arterial pressure (MAP) was measured before and during graded infusion of angiotensin II (Ang II). During high salt, ACEi reduced MAP in II and ID, but not in DD [II: 88 (78-94) versus 76 (72-88); ID: 87 (84-91) versus 83 (79-87); both P DD: 86 (82-96) versus 88 (80-90); ns, P DD: 84 (80-91) versus 81 (75-85); all P DD, with an 18% rise in MAP during the highest dose versus 22 and 31% in ID and II (P DD genotype during high salt, accompanied by blunted sensitivity to Ang II. Low salt corrects both abnormalities. Further analysis of this gene-environment interaction in patients may contribute to strategies for improvement of individual treatment efficacy.

  15. PPARγ Pro12Ala and ACE ID polymorphisms are associated with BMI and fat distribution, but not metabolic syndrome

    Directory of Open Access Journals (Sweden)

    Passaro Angela

    2011-12-01

    Full Text Available Abstract Background Metabolic Syndrome (MetS results from the combined effect of environmental and genetic factors. We investigated the possible association of peroxisome proliferator-activated receptor-γ2 (PPARγ2 Pro12Ala and Angiotensin Converting Enzyme (ACE I/D polymorphisms with MetS and interaction between these genetic variants. Methods Three hundred sixty four unrelated Caucasian subjects were enrolled. Waist circumference, blood pressure, and body mass index (BMI were recorded. Body composition was estimated by impedance analysis; MetS was diagnosed by the NCEP-ATPIII criteria. A fasting blood sample was obtained for glucose, insulin, lipid profile determination, and DNA isolation for genotyping. Results The prevalence of MetS did not differ across PPARγ2 or ACE polymorphisms. Carriers of PPARγ2 Ala allele had higher BMI and fat-mass but lower systolic blood pressure compared with Pro/Pro homozygotes. A significant PPARγ2 gene-gender interaction was observed in the modulation of BMI, fat mass, and blood pressure, with significant associations found in women only. A PPARγ2-ACE risk genotype combination for BMI and fat mass was found, with ACE DD/PPARγ2 Ala subjects having a higher BMI (p = 0.002 and Fat Mass (p = 0.002. Pro12Ala was independently associated with waist circumference independent of BMI and gender. Conclusions Carriers of PPARγ2 Ala allele had higher BMI and fat-mass but not a worse metabolic profile, possibly because of a more favorable adipose tissue distribution. A gene interaction exists between Pro12Ala and ACE I/D on BMI and fat mass. Further studies are needed to assess the contribution of Pro12Ala polymorphism in adiposity distribution.

  16. MR-based attenuation correction in brain PET based on UTE sequences

    Energy Technology Data Exchange (ETDEWEB)

    Cabello, Jorge; Nekolla, Stephan G; Ziegler, Sibylle I [Department of Nuclear Medicine, Klinikum rechts der Isar, Technische Universität München (Germany)

    2014-07-29

    Attenuation correction (AC) in brain PET/MR has recently emerged as one of the challenging tasks in the PET/MR field. It has been shown that to ignore the attenuation produced by bone can lead to errors ranging from 5-30% in regions close to bone structures. Since the information provided by the MR signal is not directly related to tissue attenuation, alternative methods have to be developed. Signal from bone tissue is difficult to measure given its short transverse relaxation time (T2). Ultrashort-echo time (UTE) pulse sequences were developed to measure signal from tissues with short T2. A combination of two consecutive UTE echoes has been used in several works to measure signal from bone tissue. The first echo is able to measure signal from bone tissue in addition to soft tissue, while the second echo contains most of the soft tissue contained in the first echo but not bone. In this work we extract the attenuation information from the difference between the logarithm of two images obtained after applying two consecutive UTE pulse sequences using the mMR scanner (Siemens Healthcare). Subsequently, image processing techniques are applied to reduce the noise and extract air cavities within the head. The resulting image is converted to linear attenuation coefficients, generating what is known as µ-map, to be used during reconstruction. For comparison purposes PET/CT scans of the same patients were acquired prior to the PET/MR scan. Additional µ-maps obtained for comparison were extracted from a Dixon sequence (used in clinical routine) and an additional µ-map calculated by the scanner based on UTE pulse sequences. Preliminary quantitative results measured in the cerebellum, using the value obtained with CT-based AC as reference, show differences of 34% without AC, 13% using the Dixon-based and UTE-based provided by the scanner, and 0.8% with the AC strategy presented here.

  17. Angiotensin-converting enzyme genotype and arterial oxygen saturation at high altitude in Peruvian Quechua.

    Science.gov (United States)

    Bigham, Abigail W; Kiyamu, Melisa; León-Velarde, Fabiola; Parra, Esteban J; Rivera-Ch, Maria; Shriver, Mark D; Brutsaert, Tom D

    2008-01-01

    The I-allele of the angiotensin-converting enzyme (ACE) gene insertion/deletion (I/D) polymorphism has been associated with performance benefits at high altitude (HA). In n = 142 young males and females of largely Quechua origins in Peru, we evaluated 3 specific hypotheses with regard to the HA benefits of the I-allele: (1) the I-allele is associated with higher arterial oxygen saturation (Sa(O(2))) at HA, (2) the I-allele effect depends on the acclimatization state of the subjects, and (3) the putative I-allele effect on Sa(O(2)) is mediated by the isocapnic hypoxic ventilatory response (HVR, l/min(1)/% Sa(O(2))(1)). The subject participants comprised two different study groups including BLA subjects (born at low altitude) who were lifelong sea-level residents transiently exposed to hypobaric hypoxia (<24 h) and BHA subjects (born at HA) who were lifelong residents of HA. To control for the possibility of population stratification, Native American ancestry proportion (NAAP) was estimated as a covariate for each individual using a panel of 70 ancestry-informative molecular markers (AIMS). At HA, resting and exercise Sa(O(2)) was strongly associated with the ACE genotype, p = 0.008 with approximately 4% of the total variance in Sa(O(2)) attributed to ACE genotype. Moreover, I/I individuals maintained approximately 2.3 percentage point higher Sa(O(2)) compared to I/D and D/D. This I-allele effect was evident in both BLA and BHA groups, suggesting that acclimatization state has little influence on the phenotypic expression of the ACE gene. Finally, ACE genotype was not associated with the isocapnic HVR, although HVR had a strong independent effect on Sa(O(2)) (p = 0.001). This suggests that the I-allele effect on Sa(O(2)) is not mediated by the peripheral control of breathing, but rather by some other central cardiopulmonary effect of the ACE gene on the renin-angiotensin-aldosterone system (RAAS).

  18. Association between ACE gene I/D polymorphism and clinical presentation and prognosis of sarcoidosis.

    Science.gov (United States)

    Alía, P; Mañá, J; Capdevila, O; Alvarez, A; Navarro, M A

    2005-01-01

    Serum angiotensin converting enzyme (SACE) concentration is considered a marker of sarcoidosis activity. This concentration is influenced by an insertion/deletion (I/D) polymorphism of the ACE gene, such that SACE levels follow the pattern DD>ID>II. The aim of our work was to study the relationship between I/D polymorphism and susceptibility to sarcoidosis, as well as the relation between this polymorphism and the clinical presentation and evolution of the disease in 177 sarcoidosis patients. A group of 104 individuals without sarcoidosis was included as control. Genotyping was done by a polymerase chain reaction (PCR) method, and SACE concentration at diagnosis was determined by a kinetic method. No differences were observed in genotype or allele distributions between patients and controls, nor between patients considering the type of presentation (Löfgren versus non-Löfgren) and evolution of the disease (acute versus chronic). As reported for healthy populations, SACE concentrations followed the pattern DD>ID>II in sarcoidosis patients, but significant differences between genotypes existed only in the Löfgren group (p = 0.003) and in acute patients (p = 0.02). SACE concentrations at diagnosis were lower in acute patients (p = 0.05) and in Löfgren's syndrome (p = 0.04), but this seemed to occur only in ID individuals (p = 0.02 and p = 0.01, respectively). No relation was thus found between I/D polymorphism and susceptibility to sarcoidosis, but ACE I/D genotyping may improve the assessment of disease activity, both at diagnosis and during the follow-up of treated and untreated patients.

  19. Study of CT-based positron range correction in high resolution 3D PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Cal-Gonzalez, J., E-mail: jacobo@nuclear.fis.ucm.es [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Herraiz, J.L. [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Espana, S. [Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Vicente, E. [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Instituto de Estructura de la Materia, Consejo Superior de Investigaciones Cientificas (CSIC), Madrid (Spain); Herranz, E. [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Desco, M. [Unidad de Medicina y Cirugia Experimental, Hospital General Universitario Gregorio Maranon, Madrid (Spain); Vaquero, J.J. [Dpto. de Bioingenieria e Ingenieria Espacial, Universidad Carlos III, Madrid (Spain); Udias, J.M. [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain)

    2011-08-21

    Positron range limits the spatial resolution of PET images and has a different effect for different isotopes and positron propagation materials. Therefore it is important to consider it during image reconstruction, in order to obtain optimal image quality. Positron range distributions for most common isotopes used in PET in different materials were computed using the Monte Carlo simulations with PeneloPET. The range profiles were introduced into the 3D OSEM image reconstruction software FIRST and employed to blur the image either in the forward projection or in the forward and backward projection. The blurring introduced takes into account the different materials in which the positron propagates. Information on these materials may be obtained, for instance, from a segmentation of a CT image. The results of introducing positron blurring in both forward and backward projection operations was compared to using it only during forward projection. Further, the effect of different shapes of positron range profile in the quality of the reconstructed images with positron range correction was studied. For high positron energy isotopes, the reconstructed images show significant improvement in spatial resolution when positron range is taken into account during reconstruction, compared to reconstructions without positron range modeling.

  20. Study of CT-based positron range correction in high resolution 3D PET imaging

    International Nuclear Information System (INIS)

    Cal-Gonzalez, J.; Herraiz, J.L.; Espana, S.; Vicente, E.; Herranz, E.; Desco, M.; Vaquero, J.J.; Udias, J.M.

    2011-01-01

    Positron range limits the spatial resolution of PET images and has a different effect for different isotopes and positron propagation materials. Therefore it is important to consider it during image reconstruction, in order to obtain optimal image quality. Positron range distributions for most common isotopes used in PET in different materials were computed using the Monte Carlo simulations with PeneloPET. The range profiles were introduced into the 3D OSEM image reconstruction software FIRST and employed to blur the image either in the forward projection or in the forward and backward projection. The blurring introduced takes into account the different materials in which the positron propagates. Information on these materials may be obtained, for instance, from a segmentation of a CT image. The results of introducing positron blurring in both forward and backward projection operations was compared to using it only during forward projection. Further, the effect of different shapes of positron range profile in the quality of the reconstructed images with positron range correction was studied. For high positron energy isotopes, the reconstructed images show significant improvement in spatial resolution when positron range is taken into account during reconstruction, compared to reconstructions without positron range modeling.

  1. Methods for Motion Correction Evaluation Using 18F-FDG Human Brain Scans on a High-Resolution PET Scanner

    DEFF Research Database (Denmark)

    Keller, Sune H.; Sibomana, Merence; Olesen, Oline Vinter

    2012-01-01

    Many authors have reported the importance of motion correction (MC) for PET. Patient motion during scanning disturbs kinetic analysis and degrades resolution. In addition, using misaligned transmission for attenuation and scatter correction may produce regional quantification bias in the reconstr......Many authors have reported the importance of motion correction (MC) for PET. Patient motion during scanning disturbs kinetic analysis and degrades resolution. In addition, using misaligned transmission for attenuation and scatter correction may produce regional quantification bias...... in the reconstructed emission images. The purpose of this work was the development of quality control (QC) methods for MC procedures based on external motion tracking (EMT) for human scanning using an optical motion tracking system. Methods: Two scans with minor motion and 5 with major motion (as reported...... (automated image registration) software. The following 3 QC methods were used to evaluate the EMT and AIR MC: a method using the ratio between 2 regions of interest with gray matter voxels (GM) and white matter voxels (WM), called GM/WM; mutual information; and cross correlation. Results: The results...

  2. The PAI-1 4G/5G and ACE I/D polymorphisms and risk of recurrent pregnancy loss: a case-control study.

    Science.gov (United States)

    Kim, Jin Ju; Choi, Young Min; Lee, Sung Ki; Yang, Kwang Moon; Paik, Eun Chan; Jeong, Hyeon Jeong; Jun, Jong Kwan; Han, Ae Ra; Hong, Min A

    2014-12-01

    Thrombophilia has been postulated to be a contributor to the pathophysiology of recurrent pregnancy loss (RPL). We investigated the role of the plasminogen activator inhibitor type 1 (PAI-1) 4G/5G and angiotensin converting enzyme (ACE) I/D polymorphisms in Korean patients with RPL. Genotyping was performed using the TaqMan assay in 227 RPL patients and 304 controls. The genotype distributions of both polymorphisms in the RPL group did not differ from those of controls. Because the frequency of being homozygous for ACE D/D and the PAI-I 4G/4G combination has been reported to be significantly higher in RPL patients, this was also analyzed. However, no significant difference was noted; 3.1% of RPL patients had both ACE D/D and PAI-I 4G/4G, as did 4.9% of controls (P = 0.791). The current study suggests that both polymorphisms, either alone or in combination, are not major determinants of the development of RPL in Korean women. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. An experimental phantom study of the effect of gadolinium-based MR contrast agents on PET attenuation coefficients and PET quantification in PET-MR imaging: application to cardiac studies.

    Science.gov (United States)

    O' Doherty, Jim; Schleyer, Paul

    2017-12-01

    Simultaneous cardiac perfusion studies are an increasing trend in PET-MR imaging. During dynamic PET imaging, the introduction of gadolinium-based MR contrast agents (GBCA) at high concentrations during a dual injection of GBCA and PET radiotracer may cause increased attenuation effects of the PET signal, and thus errors in quantification of PET images. We thus aimed to calculate the change in linear attenuation coefficient (LAC) of a mixture of PET radiotracer and increasing concentrations of GBCA in solution and furthermore, to investigate if this change in LAC produced a measurable effect on the image-based PET activity concentration when attenuation corrected by three different AC strategies. We performed simultaneous PET-MR imaging of a phantom in a static scenario using a fixed activity of 40 MBq [18 F]-NaF, water, and an increasing GBCA concentration from 0 to 66 mM (based on an assumed maximum possible concentration of GBCA in the left ventricle in a clinical study). This simulated a range of clinical concentrations of GBCA. We investigated two methods to calculate the LAC of the solution mixture at 511 keV: (1) a mathematical mixture rule and (2) CT imaging of each concentration step and subsequent conversion to LAC at 511 keV. This comparison showed that the ranges of LAC produced by both methods are equivalent with an increase in LAC of the mixed solution of approximately 2% over the range of 0-66 mM. We then employed three different attenuation correction methods to the PET data: (1) each PET scan at a specific millimolar concentration of GBCA corrected by its corresponding CT scan, (2) each PET scan corrected by a CT scan with no GBCA present (i.e., at 0 mM GBCA), and (3) a manually generated attenuation map, whereby all CT voxels in the phantom at 0 mM were replaced by LAC = 0.1 cm -1 . All attenuation correction methods (1-3) were accurate to the true measured activity concentration within 5%, and there were no trends in image

  4. Evaluation of 68Ga-DOTATOC PET/MRI for whole-body staging of neuroendocrine tumours in comparison with 68Ga-DOTATOC PET/CT.

    Science.gov (United States)

    Sawicki, Lino M; Deuschl, Cornelius; Beiderwellen, Karsten; Ruhlmann, Verena; Poeppel, Thorsten D; Heusch, Philipp; Lahner, Harald; Führer, Dagmar; Bockisch, Andreas; Herrmann, Ken; Forsting, Michael; Antoch, Gerald; Umutlu, Lale

    2017-10-01

    To compare the diagnostic performance of 68 Ga-DOTATOC PET/MRI and 68 Ga-DOTATOC PET/CT in the whole-body staging of patients with neuroendocrine tumours (NET). Thirty patients with histopathologically confirmed NET underwent PET/CT and PET/MRI in a single-injection protocol. PET/CT and PET/MRI scans were prospectively evaluated with regard to lesion count, localization, nature (NET/non-NET), and conspicuity (four-point scale). Histopathology and follow-up imaging served as the reference standards. The proportions of NET and non-NET lesions rated correctly were compared using McNemar's chi-squared test. The Wilcoxon test was used to assess differences in SUVmax and lesion conspicuity. The correlation between the SUVmax for the same lesions from each modality was analysed using Pearson's correlation coefficient (r). According to the reference standard, there were 197 lesions (142 NET, 55 non-NET). Lesion-based analysis showed a higher proportion of correctly rated NET lesions on PET/MRI than on PET/CT (90.8% vs. 86.7%, p = 0.031), whereas on PET/CT there was a higher proportion of correctly rated non-NET lesions (94.5% vs. 83.6%, p = 0.031). SUVmax was strongly correlated (r = 0.86; p PET/MRI (both p PET/MRI yielded a higher proportion of correctly rated NET lesions and should be regarded as a valuable alternative to 68 Ga-DOTATOC PET/CT in whole-body staging of NET patients. • 68 Ga-DOTATOC PET/MRI correctly identified more NET lesions than 68 Ga-DOTATOC PET/CT. • 68 Ga-DOTATOC PET/MRI provides better NET lesion conspicuity than 68 Ga-DOTATOC PET/CT. • SUVmax values from the two modalities are strongly correlated and do not differ significantly.

  5. Identification and characterisation of the angiotensin converting enzyme-3 (ACE3 gene: a novel mammalian homologue of ACE

    Directory of Open Access Journals (Sweden)

    Phelan Anne

    2007-06-01

    Full Text Available Abstract Background Mammalian angiotensin converting enzyme (ACE plays a key role in blood pressure regulation. Although multiple ACE-like proteins exist in non-mammalian organisms, to date only one other ACE homologue, ACE2, has been identified in mammals. Results Here we report the identification and characterisation of the gene encoding a third homologue of ACE, termed ACE3, in several mammalian genomes. The ACE3 gene is located on the same chromosome downstream of the ACE gene. Multiple sequence alignment and molecular modelling have been employed to characterise the predicted ACE3 protein. In mouse, rat, cow and dog, the predicted protein has mutations in some of the critical residues involved in catalysis, including the catalytic Glu in the HEXXH zinc binding motif which is Gln, and ESTs or reverse-transcription PCR indicate that the gene is expressed. In humans, the predicted ACE3 protein has an intact HEXXH motif, but there are other deletions and insertions in the gene and no ESTs have been identified. Conclusion In the genomes of several mammalian species there is a gene that encodes a novel, single domain ACE-like protein, ACE3. In mouse, rat, cow and dog ACE3, the catalytic Glu is replaced by Gln in the putative zinc binding motif, indicating that in these species ACE3 would lack catalytic activity as a zinc metalloprotease. In humans, no evidence was found that the ACE3 gene is expressed and the presence of deletions and insertions in the sequence indicate that ACE3 is a pseudogene.

  6. Zero-Echo-Time and Dixon Deep Pseudo-CT (ZeDD CT): Direct Generation of Pseudo-CT Images for Pelvic PET/MRI Attenuation Correction Using Deep Convolutional Neural Networks with Multiparametric MRI.

    Science.gov (United States)

    Leynes, Andrew P; Yang, Jaewon; Wiesinger, Florian; Kaushik, Sandeep S; Shanbhag, Dattesh D; Seo, Youngho; Hope, Thomas A; Larson, Peder E Z

    2018-05-01

    Accurate quantification of uptake on PET images depends on accurate attenuation correction in reconstruction. Current MR-based attenuation correction methods for body PET use a fat and water map derived from a 2-echo Dixon MRI sequence in which bone is neglected. Ultrashort-echo-time or zero-echo-time (ZTE) pulse sequences can capture bone information. We propose the use of patient-specific multiparametric MRI consisting of Dixon MRI and proton-density-weighted ZTE MRI to directly synthesize pseudo-CT images with a deep learning model: we call this method ZTE and Dixon deep pseudo-CT (ZeDD CT). Methods: Twenty-six patients were scanned using an integrated 3-T time-of-flight PET/MRI system. Helical CT images of the patients were acquired separately. A deep convolutional neural network was trained to transform ZTE and Dixon MR images into pseudo-CT images. Ten patients were used for model training, and 16 patients were used for evaluation. Bone and soft-tissue lesions were identified, and the SUV max was measured. The root-mean-squared error (RMSE) was used to compare the MR-based attenuation correction with the ground-truth CT attenuation correction. Results: In total, 30 bone lesions and 60 soft-tissue lesions were evaluated. The RMSE in PET quantification was reduced by a factor of 4 for bone lesions (10.24% for Dixon PET and 2.68% for ZeDD PET) and by a factor of 1.5 for soft-tissue lesions (6.24% for Dixon PET and 4.07% for ZeDD PET). Conclusion: ZeDD CT produces natural-looking and quantitatively accurate pseudo-CT images and reduces error in pelvic PET/MRI attenuation correction compared with standard methods. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  7. Effect of tubing length on the dispersion correction of an arterially sampled input function for kinetic modeling in PET.

    Science.gov (United States)

    O'Doherty, Jim; Chilcott, Anna; Dunn, Joel

    2015-11-01

    Arterial sampling with dispersion correction is routinely performed for kinetic analysis of PET studies. Because of the the advent of PET-MRI systems, non-MR safe instrumentation will be required to be kept outside the scan room, which requires the length of the tubing between the patient and detector to increase, thus worsening the effects of dispersion. We examined the effects of dispersion in idealized radioactive blood studies using various lengths of tubing (1.5, 3, and 4.5 m) and applied a well-known transmission-dispersion model to attempt to correct the resulting traces. A simulation study was also carried out to examine noise characteristics of the model. The model was applied to patient traces using a 1.5 m acquisition tubing and extended to its use at 3 m. Satisfactory dispersion correction of the blood traces was achieved in the 1.5 m line. Predictions on the basis of experimental measurements, numerical simulations and noise analysis of resulting traces show that corrections of blood data can also be achieved using the 3 m tubing. The effects of dispersion could not be corrected for the 4.5 m line by the selected transmission-dispersion model. On the basis of our setup, correction of dispersion in arterial sampling tubing up to 3 m by the transmission-dispersion model can be performed. The model could not dispersion correct data acquired using a 4.5 m arterial tubing.

  8. F-FDG PET/CT (PET/CT) influences management in patients with known or suspected pancreatic cancer

    International Nuclear Information System (INIS)

    Barber, Thomas W.; Kalff, Victor; Cherk, Martin H.; Yap, Kenneth SK.; Evans, Peter; Kelly, Michael J.

    2009-01-01

    Full text: Objective: To assess the impact on clinical management of PET/CT in patients with known or suspected pancreatic cancer. Methods: Between April 2006 and September 2008,25 PET/CT scans were performed using a dedicated PET/CT (22 scans) or a coincidence hybrid PET/CT camera (3 scans) in 23 patients with known or suspected pancreatic cancer. 17 scans were performed for initial evaluation and 8 for restaging of disease. The pre-PET/CT management plan and for intent were prospectively recorded in all cases. The post-PET/CT management plan was determined from the medical record and for discussions with treating clinicians. The impact of PET/CT on management was classified as High, Medium, Low or None, defined using ANZAPNM PET data collection project criteria. Follow-up was used to reconcile any discordance between PET/CT and conventional imaging. Results: Overall, PET/CT management impact was classified as high (n equal 7), medium (n equal 4), low (n equal 10) or none (n equal 4). Impact was either high or medium in l l/25 patients (44%) (95% confidence interval; 24 - 64%). Impact was high in 4/17 patients imaged for initial evaluation, predominantly by clarifying equivocal lesions on conventional imaging. In restaged patients, PET/CT impact was high in 3/8, and it correctly modified disease extent in 5/8. In the 16 discordant studies, PET/CT assessment was correct in 10, conventional imaging in 4 and there was insufficient information in 2. Conclusion: PET/CT has high or medium management impact in 44% of patients imaged for known or suspected pancreatic cancer, more commonly during restaging. Discordant PET/CT results were usually correct.

  9. Improved UTE-based attenuation correction for cranial PET-MR using dynamic magnetic field monitoring

    International Nuclear Information System (INIS)

    Aitken, A. P.; Giese, D.; Tsoumpas, C.; Schleyer, P.; Kozerke, S.; Prieto, C.; Schaeffter, T.

    2014-01-01

    Purpose: Ultrashort echo time (UTE) MRI has been proposed as a way to produce segmented attenuation maps for PET, as it provides contrast between bone, air, and soft tissue. However, UTE sequences require samples to be acquired during rapidly changing gradient fields, which makes the resulting images prone to eddy current artifacts. In this work it is demonstrated that this can lead to misclassification of tissues in segmented attenuation maps (AC maps) and that these effects can be corrected for by measuring the true k-space trajectories using a magnetic field camera. Methods: The k-space trajectories during a dual echo UTE sequence were measured using a dynamic magnetic field camera. UTE images were reconstructed using nominal trajectories and again using the measured trajectories. A numerical phantom was used to demonstrate the effect of reconstructing with incorrect trajectories. Images of an ovine leg phantom were reconstructed and segmented and the resulting attenuation maps were compared to a segmented map derived from a CT scan of the same phantom, using the Dice similarity measure. The feasibility of the proposed method was demonstrated inin vivo cranial imaging in five healthy volunteers. Simulated PET data were generated for one volunteer to show the impact of misclassifications on the PET reconstruction. Results: Images of the numerical phantom exhibited blurring and edge artifacts on the bone–tissue and air–tissue interfaces when nominal k-space trajectories were used, leading to misclassification of soft tissue as bone and misclassification of bone as air. Images of the tissue phantom and thein vivo cranial images exhibited the same artifacts. The artifacts were greatly reduced when the measured trajectories were used. For the tissue phantom, the Dice coefficient for bone in MR relative to CT was 0.616 using the nominal trajectories and 0.814 using the measured trajectories. The Dice coefficients for soft tissue were 0.933 and 0.934 for the

  10. Implications of ACE (I/D) Gene Variants to the Genetic Susceptibility of Coronary Artery Disease in Asian Indians.

    Science.gov (United States)

    Bhatti, G K; Bhatti, J S; Vijayvergiya, R; Singh, B

    2017-06-01

    Angiotensin-1-converting enzyme (ACE) gene has established substantial attention in the recent years as a candidate gene for hypertension, cardiovascular diseases and type 2 diabetes. The aim of the present study was to investigate the association of ACE (I/D) polymorphism with coronary artery disease (CAD) in a north Indian population. A total of 662 subjects (330 CAD patients and 332 healthy controls) were examined for association of ACE gene (I/D) polymorphism and environmental risk factors. The mean age of the CAD patients and control subjects was 60.53 ± 8.6 years and 56.55 ± 7.7 years, respectively ( p  = 0.000). Anthropometric and demographic data showed BMI values significantly higher among CAD patients and control subjects (26.98 ± 4.9 vs 24.04 ± 4.7, p  = 0.000). We observed pronounced central obesity in both CAD patients and controls, even at the lowest BMI values (ACE gene. In conclusion, DD genotype of ACE gene may be associated with increased risk of CAD in Asian Indian population.

  11. Evaluation of the ICS and DEW scatter correction methods for low statistical content scans in 3D PET

    International Nuclear Information System (INIS)

    Sossi, V.; Oakes, T.R.; Ruth, T.J.

    1996-01-01

    The performance of the Integral Convolution and the Dual Energy Window scatter correction methods in 3D PET has been evaluated over a wide range of statistical content of acquired data (1M to 400M events) The order in which scatter correction and detector normalization should be applied has also been investigated. Phantom and human neuroreceptor studies were used with the following figures of merit: axial and radial uniformity, sinogram and image noise, contrast accuracy and contrast accuracy uniformity. Both scatter correction methods perform reliably in the range of number of events examined. Normalization applied after scatter correction yields better radial uniformity and fewer image artifacts

  12. Comparison between MRI-based attenuation correction methods for brain PET in dementia patients

    International Nuclear Information System (INIS)

    Cabello, Jorge; Lukas, Mathias; Pyka, Thomas; Nekolla, Stephan G.; Ziegler, Sibylle I.; Rota Kops, Elena; Shah, N. Jon; Ribeiro, Andre; Yakushev, Igor

    2016-01-01

    The combination of Positron Emission Tomography (PET) with magnetic resonance imaging (MRI) in hybrid PET/MRI scanners offers a number of advantages in investigating brain structure and function. A critical step of PET data reconstruction is attenuation correction (AC). Accounting for bone in attenuation maps (μ-map) was shown to be important in brain PET studies. While there are a number of MRI-based AC methods, no systematic comparison between them has been performed so far. The aim of this work was to study the different performance obtained by some of the recent methods presented in the literature. To perform such a comparison, we focused on [ 18 F]-Fluorodeoxyglucose-PET/MRI neurodegenerative dementing disorders, which are known to exhibit reduced levels of glucose metabolism in certain brain regions. Four novel methods were used to calculate μ-maps from MRI data of 15 patients with Alzheimer's dementia (AD). The methods cover two atlas-based methods, a segmentation method, and a hybrid template/segmentation method. Additionally, the Dixon-based and a UTE-based method, offered by a vendor, were included in the comparison. Performance was assessed at three levels: tissue identification accuracy in the μ-map, quantitative accuracy of reconstructed PET data in specific brain regions, and precision in diagnostic images at identifying hypometabolic areas. Quantitative regional errors of -20-10 % were obtained using the vendor's AC methods, whereas the novel methods produced errors in a margin of ±5 %. The obtained precision at identifying areas with abnormally low levels of glucose uptake, potentially regions affected by AD, were 62.9 and 79.5 % for the two vendor AC methods, the former ignoring bone and the latter including bone information. The precision increased to 87.5-93.3 % in average for the four new methods, exhibiting similar performances. We confirm that the AC methods based on the Dixon and UTE sequences provided by the vendor are inferior

  13. Comparison between MRI-based attenuation correction methods for brain PET in dementia patients

    Energy Technology Data Exchange (ETDEWEB)

    Cabello, Jorge; Lukas, Mathias; Pyka, Thomas; Nekolla, Stephan G.; Ziegler, Sibylle I. [Technische Universitaet Muenchen, Nuklearmedizinische Klinik und Poliklinik, Klinikum rechts der Isar, Munich (Germany); Rota Kops, Elena; Shah, N. Jon [Forschungszentrum Juelich GmbH, Institute of Neuroscience and Medicine 4, Medical Imaging Physics, Juelich (Germany); Ribeiro, Andre [Forschungszentrum Juelich GmbH, Institute of Neuroscience and Medicine 4, Medical Imaging Physics, Juelich (Germany); Institute of Biophysics and Biomedical Engineering, Lisbon (Portugal); Yakushev, Igor [Technische Universitaet Muenchen, Nuklearmedizinische Klinik und Poliklinik, Klinikum rechts der Isar, Munich (Germany); Institute TUM Neuroimaging Center (TUM-NIC), Munich (Germany)

    2016-11-15

    The combination of Positron Emission Tomography (PET) with magnetic resonance imaging (MRI) in hybrid PET/MRI scanners offers a number of advantages in investigating brain structure and function. A critical step of PET data reconstruction is attenuation correction (AC). Accounting for bone in attenuation maps (μ-map) was shown to be important in brain PET studies. While there are a number of MRI-based AC methods, no systematic comparison between them has been performed so far. The aim of this work was to study the different performance obtained by some of the recent methods presented in the literature. To perform such a comparison, we focused on [{sup 18}F]-Fluorodeoxyglucose-PET/MRI neurodegenerative dementing disorders, which are known to exhibit reduced levels of glucose metabolism in certain brain regions. Four novel methods were used to calculate μ-maps from MRI data of 15 patients with Alzheimer's dementia (AD). The methods cover two atlas-based methods, a segmentation method, and a hybrid template/segmentation method. Additionally, the Dixon-based and a UTE-based method, offered by a vendor, were included in the comparison. Performance was assessed at three levels: tissue identification accuracy in the μ-map, quantitative accuracy of reconstructed PET data in specific brain regions, and precision in diagnostic images at identifying hypometabolic areas. Quantitative regional errors of -20-10 % were obtained using the vendor's AC methods, whereas the novel methods produced errors in a margin of ±5 %. The obtained precision at identifying areas with abnormally low levels of glucose uptake, potentially regions affected by AD, were 62.9 and 79.5 % for the two vendor AC methods, the former ignoring bone and the latter including bone information. The precision increased to 87.5-93.3 % in average for the four new methods, exhibiting similar performances. We confirm that the AC methods based on the Dixon and UTE sequences provided by the vendor are

  14. A practical head tracking system for motion correction in neurological SPECT and PET

    International Nuclear Information System (INIS)

    Fulton, R.R.; Eberl, S.; Meikle, S.; Hutton, B.F.; Braun, M.

    1998-01-01

    Full text: Patient motion during data acquisition can degrade the quality of SPECT and PET images. Techniques for motion correction in neurological studies in both modalities based on continuous monitoring of head position have been proposed. However difficulties in developing suitable head tracking systems have so far impeded clinical implementations. We have developed a head tracking system based on the mechanical ADL-1 tracker (Shooting Star Technology, Rosedale, Canada) on a Trionix triple-head SPECT camera A software driver running on a SUN Sparc host computer communicates with the tracker over a serial line providing up to 300 updates per second with angular and positional resolutions of 0.05 degrees and 0.2 mm respectively. The SUN Sparc workstation which acquires the SPECT study also communicates with the tracker, eliminating synchronisation problems. For motion correction, the motion parameters provided by the tracker within its own coordinate system must be converted to the camera's coordinate system. The conversion requires knowledge of the rotational relationships between the two coordinate systems and the displacement of their origins, both of which are determined from a calibration procedure. The tracker has been tested under clinical SPECT imaging conditions with a 3D Hoffman brain phantom. Multiple SPECT acquisitions were performed. After each acquisition the phantom was moved to a new position and orientation. Motion parameters reported by the tracker for each applied movement were compared with those obtained by applying an automated image registration program to the sequential reconstructed studies. Maximum differences were < 0.5 degrees and < 2mm, within the expected errors of the registration procedure. We conclude that this tracking system will be suitable for clinical evaluation of motion correction in SPECT and PET

  15. A proposal for PET/MRI attenuation correction with μ-values measured using a fixed-position radiation source and MRI segmentation

    Energy Technology Data Exchange (ETDEWEB)

    Kawaguchi, Hiroshi, E-mail: kwgc@nirs.go.jp [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Hirano, Yoshiyuki, E-mail: yhirano@nirs.go.jp [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Yoshida, Eiji, E-mail: rush@nirs.go.jp [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Kershaw, Jeff, E-mail: len@nirs.go.jp [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Shiraishi, Takahiro, E-mail: tshira@nirs.go.jp [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Suga, Mikio, E-mail: mikio.suga@faculty.chiba-u.jp [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Graduate School of Engineering of Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522 (Japan); Ikoma, Yoko, E-mail: ikoma@nirs.go.jp [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Obata, Takayuki, E-mail: t_obata@nirs.go.jp [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Ito, Hiroshi, E-mail: hito@nirs.go.jp [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Yamaya, Taiga, E-mail: taiga@nirs.go.jp [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan)

    2014-01-11

    Several MRI-based attenuation correction methods have been reported for PET/MRI; these methods are expected to make efficient use of high-quality anatomical MRIs and reduce the radiation dose for PET/MRI scanning. The accuracy of the attenuation map (μ-map) from an MRI depends on the accuracy of tissue segmentation and the attenuation coefficients to be assigned (μ-values). In this study, we proposed an MRI-based μ-value estimation method with a non-rotational radiation source to construct a suitable μ-map for PET/MRI. The proposed method uses an accurately segmented tissue map, the partial path length of each tissue, and detected intensities of attenuated radiation from a fixed-position (rather than a rotating) radiation source to obtain the μ-map. We estimated the partial path length from a virtual blank scan of fixed-point radiation with the same scanner geometry using the known tissue map from MRI. The μ-values of every tissue were estimated by inverting a linear relationship involving the partial path lengths and measured radioactivity intensity. Validation of the proposed method was performed by calculating a fixed- point data set based upon real a real transmission scan. The root-mean-square error between the μ-values derived from a conventional transmission scan and those obtained with our proposed method were 2.4±1.4%, 17.4±9.1% and 6.6±4.3% for brain, bone and soft tissue other than brain, respectively. Although the error estimates for bone and soft tissue are not insignificant, the method we propose is able to estimate the brain μ-value accurately and it is this factor that most strongly affects the quantitative value of PET images because of the large volumetric ratio of the brain. -- Highlights: • An MRI-derived µ-map for the attenuation correction of PET images is proposed. • Method relies on segmentation of MRI and a fixed-point source transmission scan. • Tissue segmentation reduces the number of unknown µ-values. • Method

  16. A proposal for PET/MRI attenuation correction with μ-values measured using a fixed-position radiation source and MRI segmentation

    International Nuclear Information System (INIS)

    Kawaguchi, Hiroshi; Hirano, Yoshiyuki; Yoshida, Eiji; Kershaw, Jeff; Shiraishi, Takahiro; Suga, Mikio; Ikoma, Yoko; Obata, Takayuki; Ito, Hiroshi; Yamaya, Taiga

    2014-01-01

    Several MRI-based attenuation correction methods have been reported for PET/MRI; these methods are expected to make efficient use of high-quality anatomical MRIs and reduce the radiation dose for PET/MRI scanning. The accuracy of the attenuation map (μ-map) from an MRI depends on the accuracy of tissue segmentation and the attenuation coefficients to be assigned (μ-values). In this study, we proposed an MRI-based μ-value estimation method with a non-rotational radiation source to construct a suitable μ-map for PET/MRI. The proposed method uses an accurately segmented tissue map, the partial path length of each tissue, and detected intensities of attenuated radiation from a fixed-position (rather than a rotating) radiation source to obtain the μ-map. We estimated the partial path length from a virtual blank scan of fixed-point radiation with the same scanner geometry using the known tissue map from MRI. The μ-values of every tissue were estimated by inverting a linear relationship involving the partial path lengths and measured radioactivity intensity. Validation of the proposed method was performed by calculating a fixed- point data set based upon real a real transmission scan. The root-mean-square error between the μ-values derived from a conventional transmission scan and those obtained with our proposed method were 2.4±1.4%, 17.4±9.1% and 6.6±4.3% for brain, bone and soft tissue other than brain, respectively. Although the error estimates for bone and soft tissue are not insignificant, the method we propose is able to estimate the brain μ-value accurately and it is this factor that most strongly affects the quantitative value of PET images because of the large volumetric ratio of the brain. -- Highlights: • An MRI-derived µ-map for the attenuation correction of PET images is proposed. • Method relies on segmentation of MRI and a fixed-point source transmission scan. • Tissue segmentation reduces the number of unknown µ-values. • Method

  17. SU-F-T-22: Clinical Implications When Using TG-186 (ACE) Heterogeneity Software

    Energy Technology Data Exchange (ETDEWEB)

    Likhacheva, A; Grade, E; Sadeghi, A; Sokolowski, T [Arizona Cancer Specialists, Mesa, AZ (United States)

    2016-06-15

    Purpose: The purpose of this study is to compare dosimetric calculations using traditional TG-43 formalism and Oncentra Brachy Advanced Collapsed cone Engine (ACE) TG-186 calculation algorithm in clinical setting. Methods: We analyzed dosimetry of four patients treated with accelerated partial breast irradiation using a multi-channel intracavitary device (SAVI). All patients were treated to 34 Gy in 10 fractions using a high-dose-rate (192) Ir source. The plans were designed and treated using the TG-43 model. ACE was used to assess the effect heterogeneity correction on various dosimetric parameters. Mass density was estimated using Hounsfield units. Results: Compared to TG-43 formalism, ACE estimated lower doses to targets and organs at risk. The mean difference was 19.8% (range 15.3–24.1%) for PTV-eval V200, 12.0% (range 9.7–17.7%) for PTV-eval V150, 4.3% (range 3.3–6.5%) for PTV-eval D95, 3.3% (range 1.4–5.4%) for PTV-eval D90, 5.4% (range 2.9–9.9%) for maximum rib dose, and 5.7% (2.4–7.4%) for maximum skin dose. There was no correlation between the magnitude of the difference and the PTV-eval volume, air volume, or tissue-applicator conformance. Conclusion: Based on our preliminary study, the TG-43 algorithm appears to overestimate the dose to targets and organs at risk when compared to the ACE TG-186 software. We hypothesize that air adjacent to the SAVI struts contributes to lack of scatter thereby contributing a significant difference in dose calculation when using ACE. We believe that ACE calculation provides a more realistic isodose distribution than TG-43. We plan to further investigate the impact of heterogeneity correction on brachytherapy planning for a wide variety of clinical scenarios, include skin, cervix/uterus, prostate, and lung.

  18. A virtual sinogram method to reduce dental metallic implant artefacts in computed tomography-based attenuation correction for PET

    NARCIS (Netherlands)

    Abdoli, Mehrsima; Ay, Mohammad Reza; Ahmadian, Alireza; Zaidi, Habib

    Objective Attenuation correction of PET data requires accurate determination of the attenuation map (mu map), which represents the spatial distribution of linear attenuation coefficients of different tissues at 511 keV. The presence of high-density metallic dental filling material in head and neck

  19. Preface ACE 2013

    NARCIS (Netherlands)

    Katayose, Haruhiro; Reidsma, Dennis; Katayose, Haruhiro; Nijholt, Antinus

    2013-01-01

    These are the proceedings of the 10th International Conference on Advances in Computer Entertainment (ACE 2013), hosted by the Human Media Interaction research group of the Centre for Telematics and Information Technology at the University of Twente, The Netherlands. The ACE series of conferences,

  20. Value of new MR techniques in MR-PET

    International Nuclear Information System (INIS)

    Attenberger, U.I.; Schoenberg, S.O.; Quick, H.H.; Guimaraes, A.; Catalano, O.; Morelli, J.N.

    2013-01-01

    The unparalleled soft tissue contrast of magnetic resonance imaging (MRI) and the functional information obtainable with 18-F fluorodeoxyglucose positron emission tomography (FDG-PET) render MR-PET well-suited for oncological and psychiatric imaging. The lack of ionizing radiation with MRI also makes MR-PET a promising modality for oncology patients requiring frequent follow-up and pediatric patients. Lessons learned with PET computed tomography (CT) over the last few years do not directly translate to MR-PET. For example, in PET-CT the Hounsfield units derived from CT are used for attenuation correction (AC). As 511 keV photons emitted in PET examinations are attenuated by the patient's body CT data are converted directly to linear attenuation coefficients (LAC); however, proton density measured by MRI is not directly related to the radiodensity or LACs of biological tissue. Thus, direct conversion to LAC data is not possible making AC more challenging in simultaneous MRI-PET scanning. In addition to these constraints simultaneous MRI-PET acquisitions also improve on some solutions to well-known challenges of hybrid imaging techniques, such as limitations in motion correction. This article reports on initial clinical experiences with simultaneously acquired MRI-PET data, focusing on the potential benefits and limitations of MRI with respect to motion correction as well as metal and attenuation correction artefacts. (orig.) [de

  1. Angiotensin converting enzyme gene polymorphism and ACE inhibition in diabetic nephropathy

    DEFF Research Database (Denmark)

    Jacobsen, P; Rossing, K; Rossing, P

    1998-01-01

    induced a significant reduction in MABP, albuminuria and kidney function in all three groups (II/ID/DD; P ANOVA, P = 0.02); (2) albuminuria [mean (95% CI)] 61 (34 to 77)/22 (3 to 37)/31 (13 to 46) %, (ANOVA, P ... serum creatinine [mean (95% CI)] 8 (4 to 12)/9 (3 to 16)/8 (0 to 16) % (ANOVA, NS), respectively. Adjusting for differences in reduction in MABP did not change the association between decrease in albuminuria and ACE/ID genotypes (P

  2. An Angiotensin I-Converting Enzyme Mutation (Y465D) Causes a Dramatic Increase in Blood ACE via Accelerated ACE Shedding

    Science.gov (United States)

    Gordon, Kerry; Nesterovitch, Andrew B.; Lünsdorf, Heinrich; Chen, Zhenlong; Castellon, Maricela; Popova, Isolda A.; Kalinin, Sergey; Mendonca, Emma; Petukhov, Pavel A.; Schwartz, David E.

    2011-01-01

    Background Angiotensin I-converting enzyme (ACE) metabolizes a range of peptidic substrates and plays a key role in blood pressure regulation and vascular remodeling. Thus, elevated ACE levels may be associated with an increased risk for different cardiovascular or respiratory diseases. Previously, a striking familial elevation in blood ACE was explained by mutations in the ACE juxtamembrane region that enhanced the cleavage-secretion process. Recently, we found a family whose affected members had a 6-fold increase in blood ACE and a Tyr465Asp (Y465D) substitution, distal to the stalk region, in the N domain of ACE. Methodology/Principal Findings HEK and CHO cells expressing mutant (Tyr465Asp) ACE demonstrate a 3- and 8-fold increase, respectively, in the rate of ACE shedding compared to wild-type ACE. Conformational fingerprinting of mutant ACE demonstrated dramatic changes in ACE conformation in several different epitopes of ACE. Cell ELISA carried out on CHO-ACE cells also demonstrated significant changes in local ACE conformation, particularly proximal to the stalk region. However, the cleavage site of the mutant ACE - between Arg1203 and Ser1204 - was the same as that of WT ACE. The Y465D substitution is localized in the interface of the N-domain dimer (from the crystal structure) and abolishes a hydrogen bond between Tyr465 in one monomer and Asp462 in another. Conclusions/Significance The Y465D substitution results in dramatic increase in the rate of ACE shedding and is associated with significant local conformational changes in ACE. These changes could result in increased ACE dimerization and accessibility of the stalk region or the entire sACE, thus increasing the rate of cleavage by the putative ACE secretase (sheddase). PMID:21998728

  3. An angiotensin I-converting enzyme mutation (Y465D causes a dramatic increase in blood ACE via accelerated ACE shedding.

    Directory of Open Access Journals (Sweden)

    Sergei M Danilov

    Full Text Available Angiotensin I-converting enzyme (ACE metabolizes a range of peptidic substrates and plays a key role in blood pressure regulation and vascular remodeling. Thus, elevated ACE levels may be associated with an increased risk for different cardiovascular or respiratory diseases. Previously, a striking familial elevation in blood ACE was explained by mutations in the ACE juxtamembrane region that enhanced the cleavage-secretion process. Recently, we found a family whose affected members had a 6-fold increase in blood ACE and a Tyr465Asp (Y465D substitution, distal to the stalk region, in the N domain of ACE.HEK and CHO cells expressing mutant (Tyr465Asp ACE demonstrate a 3- and 8-fold increase, respectively, in the rate of ACE shedding compared to wild-type ACE. Conformational fingerprinting of mutant ACE demonstrated dramatic changes in ACE conformation in several different epitopes of ACE. Cell ELISA carried out on CHO-ACE cells also demonstrated significant changes in local ACE conformation, particularly proximal to the stalk region. However, the cleavage site of the mutant ACE--between Arg1203 and Ser1204--was the same as that of WT ACE. The Y465D substitution is localized in the interface of the N-domain dimer (from the crystal structure and abolishes a hydrogen bond between Tyr465 in one monomer and Asp462 in another.The Y465D substitution results in dramatic increase in the rate of ACE shedding and is associated with significant local conformational changes in ACE. These changes could result in increased ACE dimerization and accessibility of the stalk region or the entire sACE, thus increasing the rate of cleavage by the putative ACE secretase (sheddase.

  4. Interaction of angiotensin-converting enzyme (ACE) with membrane-bound carboxypeptidase M (CPM) - a new function of ACE.

    Science.gov (United States)

    Sun, Xiaoou; Wiesner, Burkhard; Lorenz, Dorothea; Papsdorf, Gisela; Pankow, Kristin; Wang, Po; Dietrich, Nils; Siems, Wolf-Eberhard; Maul, Björn

    2008-12-01

    Angiotensin-converting enzyme (ACE) demonstrates, besides its typical dipeptidyl-carboxypeptidase activity, several unusual functions. Here, we demonstrate with molecular, biochemical, and cellular techniques that the somatic wild-type murine ACE (mACE), stably transfected in Chinese Hamster Ovary (CHO) or Madin-Darby Canine Kidney (MDCK) cells, interacts with endogenous membranal co-localized carboxypeptidase M (CPM). CPM belongs to the group of glycosylphosphatidylinositol (GPI)-anchored proteins. Here we report that ACE, completely independent of its known dipeptidase activities, has GPI-targeted properties. Our results indicate that the spatial proximity between mACE and the endogenous CPM enables an ACE-evoked release of CPM. These results are discussed with respect to the recently proposed GPI-ase activity and function of sperm-bound ACE.

  5. Comparison of Angiotensin Converting Enzyme (ACE gene polymorphisms elite basketball players and volleyball players

    Directory of Open Access Journals (Sweden)

    Emin Süel

    2015-09-01

    Full Text Available Aim: The purpose of this study is to research the differences of genotype polymorphism between the elite male and elite female basketball player, volleyball player and control group. Material and Methods: 58 basketball players (ages 24.25±4.99 years, height 188.22±12.31 cm and weight 80.62±16.34 kg, 64 volleyball players (ages 22.82±5.40 years, height 188.67±9.69 cm and weight 77.82±12.14 kg and 122 sedentary subjects (control group were participated randomly in the study. 5cc blood was taken control and control groups for measuring the ACE gene polymorphism. Chi-square and analysis of variance (ANOVA, Levene’s Tests, and frequencies of allele were used for statistical evaluation at significance level p0.05, basketball, volleyball and control group (p>0.05, male basketball, volleyball and control group (p>0.05, female basketball, volleyball and control group (p>0.05 and male and female athletes (p>0.05 respectively. There were no significance differences in male athletes between the genotype distribution and physical performance tests, such as 20m shuttle-run (F=1.31, vertical jump (F=0.22, and 20m sprint test (F=0.44. There were also no significance differences in female athletes between the genotype distribution and physical performance tests, such as 20m shuttle-run (F=2.03, vertical jump (F=0.10, and 20m sprint test (F=1.17. Conclusion: ACE polymorphism genotype distribution in terms of elite female and male volleyball players with elite female and male basketball players are the same.

  6. The usefulness of the combined PET-CT scanner

    International Nuclear Information System (INIS)

    Yoshikawa, Kyosan

    2003-01-01

    Recently, combined PET-CT scanners that simultaneously reveal both anatomical and metabolic images within the body have been developed. The Siemens Biograph was the first PET-CT used in Japan and was installed at National Institute of Radiological Sciences (NIRS) at the end of March 2002. The Biograph system integrates Siemens PET (HR+) and spiral CT (SOMATOM Emotion Duo) technologies with a multimodality computer platform. The CT data obtained with PET-CT is also used for attenuation corrections of the PET images. The advantages of PET-CT for clinical use are much shorter study time for each patient, easy and precise alignment of the patient's lesion within the PET field of view, an increase in PET image quality due to the CT attenuation correction system which gives a higher spatial resolution and produces much less noise in the attenuation correction data, and an improvement in diagnostic accuracy provided by both functional and anatomic imaging. The Japanese government has not yet approved the marketing of PET-CT. We are continuing to investigate its usefulness. We expect that PET-CT will be a major diagnostic tool for oncology imaging in the near future. (authors)

  7. Corrections of arterial input function for dynamic H215O PET to assess perfusion of pelvic tumours: arterial blood sampling versus image extraction

    International Nuclear Information System (INIS)

    Luedemann, L; Sreenivasa, G; Michel, R; Rosner, C; Plotkin, M; Felix, R; Wust, P; Amthauer, H

    2006-01-01

    Assessment of perfusion with 15 O-labelled water (H 2 15 O) requires measurement of the arterial input function (AIF). The arterial time activity curve (TAC) measured using the peripheral sampling scheme requires corrections for delay and dispersion. In this study, parametrizations with and without arterial spillover correction for fitting of the tissue curve are evaluated. Additionally, a completely noninvasive method for generation of the AIF from a dynamic positron emission tomography (PET) acquisition is applied to assess perfusion of pelvic tumours. This method uses a volume of interest (VOI) to extract the TAC from the femoral artery. The VOI TAC is corrected for spillover using a separate tissue TAC and for recovery by determining the recovery coefficient on a coregistered CT data set. The techniques were applied in five patients with pelvic tumours who underwent a total of 11 examinations. Delay and dispersion correction of the blood TAC without arterial spillover correction yielded in seven examinations solutions inconsistent with physiology. Correction of arterial spillover increased the fitting accuracy and yielded consistent results in all patients. Generation of an AIF from PET image data was investigated as an alternative to arterial blood sampling and was shown to have an intrinsic potential to determine the AIF noninvasively and reproducibly. The AIF extracted from a VOI in a dynamic PET scan was similar in shape to the blood AIF but yielded significantly higher tissue perfusion values (mean of 104.0 ± 52.0%) and lower partition coefficients (-31.6 ± 24.2%). The perfusion values and partition coefficients determined with the VOI technique have to be corrected in order to compare the results with those of studies using a blood AIF

  8. Correcting for respiratory motion in liver PET/MRI: preliminary evaluation of the utility of bellows and navigated hepatobiliary phase imaging

    International Nuclear Information System (INIS)

    Hope, Thomas A.; Verdin, Emily F.; Bergsland, Emily K.; Ohliger, Michael A.; Corvera, Carlos University; Nakakura, Eric K.

    2015-01-01

    The purpose of this study was to evaluate the utility of bellows-based respiratory compensation and navigated hepatobiliary phase imaging to correct for respiratory motion in the setting of dedicated liver PET/MRI. Institutional review board approval and informed consent were obtained. Six patients with metastatic neuroendocrine tumor were imaged using Ga-68 DOTA-TOC PET/MRI. Whole body imaging and a dedicated 15-min liver PET acquisition was performed, in addition to navigated and breath-held hepatobiliary phase (HBP) MRI. Liver PET data was reconstructed three ways: the entire data set (liver PET), gated using respiratory bellows (RC-liver PET), and a non-gated data set reconstructed using the same amount of data used in the RC-liver PET (shortened liver PET). Liver lesions were evaluated using SUV max , SUV peak , SUV mean , and Vol isocontour . Additionally, the displacement of each lesion between the RC-liver PET images and the navigated and breath-held HBP images was calculated. Respiratory compensation resulted in a 43 % increase in SUVs compared to ungated data (liver vs RC-liver PET SUV max 26.0 vs 37.3, p < 0.001) and a 25 % increase compared to a non-gated reconstruction using the same amount of data (RC-liver vs shortened liver PET SUV max 26.0 vs 32.6, p < 0.001). Lesion displacement was minimized using navigated HBP MRI (1.3 ± 1.0 mm) compared to breath-held HBP MRI (23.3 ± 1.0 mm). Respiratory bellows can provide accurate respiratory compensation when imaging liver lesions using PET/MRI, and results in increased SUVs due to a combination of increased image noise and reduced respiratory blurring. Additionally, navigated HBP MRI accurately aligns with respiratory compensated PET data.

  9. Correcting for respiratory motion in liver PET/MRI: preliminary evaluation of the utility of bellows and navigated hepatobiliary phase imaging

    Energy Technology Data Exchange (ETDEWEB)

    Hope, Thomas A. [Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA (United States); Department of Radiology, San Francisco VA Medical Center, San Francisco, CA (United States); Verdin, Emily F. [Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA (United States); Bergsland, Emily K. [Division of Hematology/Oncology, Department of Medicine, University of California, San Francisco, San Francisco, CA (United States); Ohliger, Michael A. [Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA (United States); Department of Radiology, San Francisco General Hospital, San Francisco, CA (United States); Corvera, Carlos University; Nakakura, Eric K. [Division of Surgical Oncology, Department of Surgery, University of California, San Francisco, San Francisco, CA (United States)

    2015-09-18

    The purpose of this study was to evaluate the utility of bellows-based respiratory compensation and navigated hepatobiliary phase imaging to correct for respiratory motion in the setting of dedicated liver PET/MRI. Institutional review board approval and informed consent were obtained. Six patients with metastatic neuroendocrine tumor were imaged using Ga-68 DOTA-TOC PET/MRI. Whole body imaging and a dedicated 15-min liver PET acquisition was performed, in addition to navigated and breath-held hepatobiliary phase (HBP) MRI. Liver PET data was reconstructed three ways: the entire data set (liver PET), gated using respiratory bellows (RC-liver PET), and a non-gated data set reconstructed using the same amount of data used in the RC-liver PET (shortened liver PET). Liver lesions were evaluated using SUV{sub max}, SUV{sub peak}, SUV{sub mean}, and Vol{sub isocontour}. Additionally, the displacement of each lesion between the RC-liver PET images and the navigated and breath-held HBP images was calculated. Respiratory compensation resulted in a 43 % increase in SUVs compared to ungated data (liver vs RC-liver PET SUV{sub max} 26.0 vs 37.3, p < 0.001) and a 25 % increase compared to a non-gated reconstruction using the same amount of data (RC-liver vs shortened liver PET SUV{sub max} 26.0 vs 32.6, p < 0.001). Lesion displacement was minimized using navigated HBP MRI (1.3 ± 1.0 mm) compared to breath-held HBP MRI (23.3 ± 1.0 mm). Respiratory bellows can provide accurate respiratory compensation when imaging liver lesions using PET/MRI, and results in increased SUVs due to a combination of increased image noise and reduced respiratory blurring. Additionally, navigated HBP MRI accurately aligns with respiratory compensated PET data.

  10. Correction for FDG PET dose extravasations: Monte Carlo validation and quantitative evaluation of patient studies

    Energy Technology Data Exchange (ETDEWEB)

    Silva-Rodríguez, Jesús, E-mail: jesus.silva.rodriguez@sergas.es; Aguiar, Pablo, E-mail: pablo.aguiar.fernandez@sergas.es [Fundación Ramón Domínguez, Santiago de Compostela, Galicia (Spain); Servicio de Medicina Nuclear, Complexo Hospitalario Universidade de Santiago de Compostela (USC), 15782, Galicia (Spain); Grupo de Imaxe Molecular, Instituto de Investigación Sanitarias (IDIS), Santiago de Compostela, 15706, Galicia (Spain); Sánchez, Manuel; Mosquera, Javier; Luna-Vega, Víctor [Servicio de Radiofísica y Protección Radiológica, Complexo Hospitalario Universidade de Santiago de Compostela (USC), 15782, Galicia (Spain); Cortés, Julia; Garrido, Miguel [Servicio de Medicina Nuclear, Complexo Hospitalario Universitario de Santiago de Compostela, 15706, Galicia, Spain and Grupo de Imaxe Molecular, Instituto de Investigación Sanitarias (IDIS), Santiago de Compostela, 15706, Galicia (Spain); Pombar, Miguel [Servicio de Radiofísica y Protección Radiológica, Complexo Hospitalario Universitario de Santiago de Compostela, 15706, Galicia (Spain); Ruibal, Álvaro [Servicio de Medicina Nuclear, Complexo Hospitalario Universidade de Santiago de Compostela (USC), 15782, Galicia (Spain); Grupo de Imaxe Molecular, Instituto de Investigación Sanitarias (IDIS), Santiago de Compostela, 15706, Galicia (Spain); Fundación Tejerina, 28003, Madrid (Spain)

    2014-05-15

    Purpose: Current procedure guidelines for whole body [18F]fluoro-2-deoxy-D-glucose (FDG)-positron emission tomography (PET) state that studies with visible dose extravasations should be rejected for quantification protocols. Our work is focused on the development and validation of methods for estimating extravasated doses in order to correct standard uptake value (SUV) values for this effect in clinical routine. Methods: One thousand three hundred sixty-seven consecutive whole body FDG-PET studies were visually inspected looking for extravasation cases. Two methods for estimating the extravasated dose were proposed and validated in different scenarios using Monte Carlo simulations. All visible extravasations were retrospectively evaluated using a manual ROI based method. In addition, the 50 patients with higher extravasated doses were also evaluated using a threshold-based method. Results: Simulation studies showed that the proposed methods for estimating extravasated doses allow us to compensate the impact of extravasations on SUV values with an error below 5%. The quantitative evaluation of patient studies revealed that paravenous injection is a relatively frequent effect (18%) with a small fraction of patients presenting considerable extravasations ranging from 1% to a maximum of 22% of the injected dose. A criterion based on the extravasated volume and maximum concentration was established in order to identify this fraction of patients that might be corrected for paravenous injection effect. Conclusions: The authors propose the use of a manual ROI based method for estimating the effectively administered FDG dose and then correct SUV quantification in those patients fulfilling the proposed criterion.

  11. A preliminary perusal of ACE I/D polymorphism with adiposity traits and blood pressure among the AO NAGAS: Does gender-dependent gene expression matter?

    Directory of Open Access Journals (Sweden)

    Imkongtenla Pongen

    2016-12-01

    Full Text Available This study aims to evaluate the association of gender-dependent expression of angiotensin converting enzyme gene polymorphism (I/D with adiposity markers and blood pressure among AoNagas.57AoNagas[Males (n =26; Females (n = 31; Mean Age: 30.56±7.5 and 31.9 ±8.3 1]residing in Delhi were included in this cross sectionalstudy. Anthropometric measurements and blood pressure were taken using standardized techniques. Adiposity indices viz., BMI, WHR and WHtR were computed. Body fat percentage was assessed by bioelectricimpedance technique using Tanita Body composition analyzer (T-6360. Venous blood samples were withdrawn for DNA extraction and genotyping of ACE gene (I/D polymorphism was established by polymerase chain reaction (PCR. In female participants with DD homozygote, risk of both general and central obesity as depicted by BMI, body fat percentage, WC, WHR and WHtR were higher than ID heterozygote. Risk of hypertension was found to be greater among males with DD homozygote rather than females with DD homozygote. In males, obesity was not found to be associated with hypertension in either DD or ID genotypic variants of ACE. Whereas, in females obesity was significantly and positively correlated with hypertension in both DD and ID genotype. DD homozygous form of ACE is linked with both obesity and blood pressure in females and only with blood pressure in males. This genotype-by-gender interaction gives us a facet in understanding the complex genetic basis of adiposity and blood pressure phenotypes.

  12. Tissue-specific expression of transgenic secreted ACE in vasculature can restore normal kidney functions, but not blood pressure, of Ace-/- mice.

    Directory of Open Access Journals (Sweden)

    Saurabh Chattopadhyay

    Full Text Available Angiotensin-converting enzyme (ACE regulates normal blood pressure and fluid homeostasis through its action in the renin-angiotensin-system (RAS. Ace-/- mice are smaller in size, have low blood pressure and defective kidney structure and functions. All of these defects are cured by transgenic expression of somatic ACE (sACE in vascular endothelial cells of Ace-/- mice. sACE is expressed on the surface of vascular endothelial cells and undergoes a natural cleavage secretion process to generate a soluble form in the body fluids. Both the tissue-bound and the soluble forms of ACE are enzymatically active, and generate the vasoactive octapeptide Angiotensin II (Ang II with equal efficiency. To assess the relative physiological roles of the secreted and the cell-bound forms of ACE, we expressed, in the vascular endothelial cells of Ace-/- mice, the ectodomain of sACE, which corresponded to only the secreted form of ACE. Our results demonstrated that the secreted form of ACE could normalize kidney functions and RAS integrity, growth and development of Ace-/- mice, but not their blood pressure. This study clearly demonstrates that the secreted form of ACE cannot replace the tissue-bound ACE for maintaining normal blood pressure; a suitable balance between the tissue-bound and the soluble forms of ACE is essential for maintaining all physiological functions of ACE.

  13. Tissue-specific expression of transgenic secreted ACE in vasculature can restore normal kidney functions, but not blood pressure, of Ace-/- mice.

    Science.gov (United States)

    Chattopadhyay, Saurabh; Kessler, Sean P; Colucci, Juliana Almada; Yamashita, Michifumi; Senanayake, Preenie deS; Sen, Ganes C

    2014-01-01

    Angiotensin-converting enzyme (ACE) regulates normal blood pressure and fluid homeostasis through its action in the renin-angiotensin-system (RAS). Ace-/- mice are smaller in size, have low blood pressure and defective kidney structure and functions. All of these defects are cured by transgenic expression of somatic ACE (sACE) in vascular endothelial cells of Ace-/- mice. sACE is expressed on the surface of vascular endothelial cells and undergoes a natural cleavage secretion process to generate a soluble form in the body fluids. Both the tissue-bound and the soluble forms of ACE are enzymatically active, and generate the vasoactive octapeptide Angiotensin II (Ang II) with equal efficiency. To assess the relative physiological roles of the secreted and the cell-bound forms of ACE, we expressed, in the vascular endothelial cells of Ace-/- mice, the ectodomain of sACE, which corresponded to only the secreted form of ACE. Our results demonstrated that the secreted form of ACE could normalize kidney functions and RAS integrity, growth and development of Ace-/- mice, but not their blood pressure. This study clearly demonstrates that the secreted form of ACE cannot replace the tissue-bound ACE for maintaining normal blood pressure; a suitable balance between the tissue-bound and the soluble forms of ACE is essential for maintaining all physiological functions of ACE.

  14. Polymorphism of the ACE gene and the risk of obstructive sleep apnoea.

    Science.gov (United States)

    Chmielewska, Izabela; Mlak, Radosław; Krawczyk, Paweł; Czukiewska, Ewa; Milanowski, Janusz

    2013-01-01

    Obstructive sleep apnoea/hypopnea syndrome (OSA) is characterized by obstruction of the upper airway during sleep, resulting in repetitive breathing pauses accompanied by oxygen desaturation and arousal from sleep. Among the candidate genes affecting the risk of OSA, genes whose polymorphisms influence the development of diseases with similar pathogenesis such as OSA could be listed: APOE, genes for leptin and leptin receptor, TNFA1, ADRB2 and ACE (gene for angiotensin-converting enzyme). Until now there has been a confirmed relationship between ACE gene polymorphism and cardiovascular diseases, but its effect on the incidence of OSA is debatable. The aim of this study was to investigate the effect of ACE gene insertion/deletion (I/D) polymorphism on the risk of OSA. Fifty-five patients with confirmed diagnose of OSA and qualified to CPAP therapy entered the study. The control group included 50 subjects who did not complain of any sleep related symptoms. Diagnose of OSA was set on the basis of full overnight polysomnography together with Epworth Sleepiness Scale according to American Academy of Sleep Medicine guidelines. DNA was isolated from peripheral blood leukocytes with Qiagen DNA mini Kit. ACE gene polymorphism was determined in genomic DNA using allele specific polymerase chain reaction. Different sizes of PCR products were observed on agarose gel electrophoresis. There were non-significant differences in the frequency of ACE genotypes. However, allele D had significantly lower prevalence in the study group than in the control group. (χ(2) = 4.25 p = 0.04). Moreover, I allele carriers had a threefold greater risk of developing OSA (HR = 2.748, 95% CI = 1.029-7.340, p gene polymorphism might be useful to determine the risk of developing OSA in clinically predisposed patients.

  15. Head motion evaluation and correction for PET scans with 18F-FDG in the Japanese Alzheimer's disease neuroimaging initiative (J-ADNI) multi-center study.

    Science.gov (United States)

    Ikari, Yasuhiko; Nishio, Tomoyuki; Makishi, Yoko; Miya, Yukari; Ito, Kengo; Koeppe, Robert A; Senda, Michio

    2012-08-01

    Head motion during 30-min (six 5-min frames) brain PET scans starting 30 min post-injection of FDG was evaluated together with the effect of post hoc motion correction between frames in J-ADNI multicenter study carried out in 24 PET centers on a total of 172 subjects consisting of 81 normal subjects, 55 mild cognitive impairment (MCI) and 36 mild Alzheimer's disease (AD) patients. Based on the magnitude of the between-frame co-registration parameters, the scans were classified into six levels (A-F) of motion degree. The effect of motion and its correction was evaluated using between-frame variation of the regional FDG uptake values on ROIs placed over cerebral cortical areas. Although AD patients tended to present larger motion (motion level E or F in 22 % of the subjects) than MCI (3 %) and normal (4 %) subjects, unignorable motion was observed in a small number of subjects in the latter groups as well. The between-frame coefficient of variation (SD/mean) was 0.5 % in the frontal, 0.6 % in the parietal and 1.8 % in the posterior cingulate ROI for the scans of motion level 1. The respective values were 1.5, 1.4, and 3.6 % for the scans of motion level F, but reduced by the motion correction to 0.5, 0.4 and 0.8 %, respectively. The motion correction changed the ROI value for the posterior cingulate cortex by 11.6 % in the case of severest motion. Substantial head motion occurs in a fraction of subjects in a multicenter setup which includes PET centers lacking sufficient experience in imaging demented patients. A simple frame-by-frame co-registration technique that can be applied to any PET camera model is effective in correcting for motion and improving quantitative capability.

  16. SU-E-I-07: An Improved Technique for Scatter Correction in PET

    International Nuclear Information System (INIS)

    Lin, S; Wang, Y; Lue, K; Lin, H; Chuang, K

    2014-01-01

    Purpose: In positron emission tomography (PET), the single scatter simulation (SSS) algorithm is widely used for scatter estimation in clinical scans. However, bias usually occurs at the essential steps of scaling the computed SSS distribution to real scatter amounts by employing the scatter-only projection tail. The bias can be amplified when the scatter-only projection tail is too small, resulting in incorrect scatter correction. To this end, we propose a novel scatter calibration technique to accurately estimate the amount of scatter using pre-determined scatter fraction (SF) function instead of the employment of scatter-only tail information. Methods: As the SF depends on the radioactivity distribution and the attenuating material of the patient, an accurate theoretical relation cannot be devised. Instead, we constructed an empirical transformation function between SFs and average attenuation coefficients based on a serious of phantom studies with different sizes and materials. From the average attenuation coefficient, the predicted SFs were calculated using empirical transformation function. Hence, real scatter amount can be obtained by scaling the SSS distribution with the predicted SFs. The simulation was conducted using the SimSET. The Siemens Biograph™ 6 PET scanner was modeled in this study. The Software for Tomographic Image Reconstruction (STIR) was employed to estimate the scatter and reconstruct images. The EEC phantom was adopted to evaluate the performance of our proposed technique. Results: The scatter-corrected image of our method demonstrated improved image contrast over that of SSS. For our technique and SSS of the reconstructed images, the normalized standard deviation were 0.053 and 0.182, respectively; the root mean squared errors were 11.852 and 13.767, respectively. Conclusion: We have proposed an alternative method to calibrate SSS (C-SSS) to the absolute scatter amounts using SF. This method can avoid the bias caused by the insufficient

  17. SU-E-I-07: An Improved Technique for Scatter Correction in PET

    Energy Technology Data Exchange (ETDEWEB)

    Lin, S; Wang, Y; Lue, K; Lin, H; Chuang, K [Chuang, National Tsing Hua University, Hsichu, Taiwan (China)

    2014-06-01

    Purpose: In positron emission tomography (PET), the single scatter simulation (SSS) algorithm is widely used for scatter estimation in clinical scans. However, bias usually occurs at the essential steps of scaling the computed SSS distribution to real scatter amounts by employing the scatter-only projection tail. The bias can be amplified when the scatter-only projection tail is too small, resulting in incorrect scatter correction. To this end, we propose a novel scatter calibration technique to accurately estimate the amount of scatter using pre-determined scatter fraction (SF) function instead of the employment of scatter-only tail information. Methods: As the SF depends on the radioactivity distribution and the attenuating material of the patient, an accurate theoretical relation cannot be devised. Instead, we constructed an empirical transformation function between SFs and average attenuation coefficients based on a serious of phantom studies with different sizes and materials. From the average attenuation coefficient, the predicted SFs were calculated using empirical transformation function. Hence, real scatter amount can be obtained by scaling the SSS distribution with the predicted SFs. The simulation was conducted using the SimSET. The Siemens Biograph™ 6 PET scanner was modeled in this study. The Software for Tomographic Image Reconstruction (STIR) was employed to estimate the scatter and reconstruct images. The EEC phantom was adopted to evaluate the performance of our proposed technique. Results: The scatter-corrected image of our method demonstrated improved image contrast over that of SSS. For our technique and SSS of the reconstructed images, the normalized standard deviation were 0.053 and 0.182, respectively; the root mean squared errors were 11.852 and 13.767, respectively. Conclusion: We have proposed an alternative method to calibrate SSS (C-SSS) to the absolute scatter amounts using SF. This method can avoid the bias caused by the insufficient

  18. Clinical applications of PET/CT

    International Nuclear Information System (INIS)

    Le Ngoc Ha

    2011-01-01

    The purpose of this article is to review the evolution of PET, PET/CT focusing on the technical aspects, PET radiopharmaceutical developments and current clinical applications as well. The newest technologic advances have been reviewed, including improved crystal design, acquisition modes, reconstruction algorithms, etc. These advancements will continue to improve contrast, decrease noise, and increase resolution. Combined PET/CT system provides faster attenuation correction and useful anatomic correlation to PET functional information. A number of new radiopharmaceuticals used for PET imaging have been developed, however, FDG have been considered as the principal PET radiotracer. The current clinical applications of PET and PET/CT are widespread and include oncology, cardiology and neurology. (author)

  19. Value of new MR techniques in MR-PET; Stellenwert neuer MR-Techniken in der MR-PET

    Energy Technology Data Exchange (ETDEWEB)

    Attenberger, U.I.; Schoenberg, S.O. [Universitaetsmedizin Mannheim, Medizinische Fakultaet Mannheim der Universitaet Heidelberg, Institut fuer klinische Radiologie und Nuklearmedizin, Mannheim (Germany); Quick, H.H. [Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Institut fuer Medizinische Physik, Erlangen (Germany); Guimaraes, A. [Massachusetts General Hospital, Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown (United States); Catalano, O. [University of Naples Federico II, Naples (Italy); Morelli, J.N. [The Johns Hopkins Hospital, The Russell H. Morgan Department of Radiology and Radiological Science, Baltimore (United States)

    2013-12-15

    The unparalleled soft tissue contrast of magnetic resonance imaging (MRI) and the functional information obtainable with 18-F fluorodeoxyglucose positron emission tomography (FDG-PET) render MR-PET well-suited for oncological and psychiatric imaging. The lack of ionizing radiation with MRI also makes MR-PET a promising modality for oncology patients requiring frequent follow-up and pediatric patients. Lessons learned with PET computed tomography (CT) over the last few years do not directly translate to MR-PET. For example, in PET-CT the Hounsfield units derived from CT are used for attenuation correction (AC). As 511 keV photons emitted in PET examinations are attenuated by the patient's body CT data are converted directly to linear attenuation coefficients (LAC); however, proton density measured by MRI is not directly related to the radiodensity or LACs of biological tissue. Thus, direct conversion to LAC data is not possible making AC more challenging in simultaneous MRI-PET scanning. In addition to these constraints simultaneous MRI-PET acquisitions also improve on some solutions to well-known challenges of hybrid imaging techniques, such as limitations in motion correction. This article reports on initial clinical experiences with simultaneously acquired MRI-PET data, focusing on the potential benefits and limitations of MRI with respect to motion correction as well as metal and attenuation correction artefacts. (orig.) [German] Die klinische Implementierung der neuen Hybridtechnologie MR-Positronenemissionstomographie (MR-PET) bietet durch die Kombination aus hochaufloesender Morphologie, Funktion und Metabolismus bisher ungeahnte diagnostische Moeglichkeiten, die nicht nur fuer die Diagnose und die Verlaufskontrolle onkologischer und psychiatrischer Erkrankungen von hoher Bedeutung sind. Verglichen mit der PET-CT wird dies mit reduzierter Strahlenbelastung fuer den Patienten moeglich, was wiederum insbesondere fuer Patienten in der Tumornachsorge, die

  20. Multi-contrast attenuation map synthesis for PET/MR scanners: assessment on FDG and Florbetapir PET tracers

    Energy Technology Data Exchange (ETDEWEB)

    Burgos, Ninon [University College London, Translational Imaging Group, Centre for Medical Image Computing, London (United Kingdom); Cardoso, M.J.; Modat, Marc; Ourselin, Sebastien [University College London, Translational Imaging Group, Centre for Medical Image Computing, London (United Kingdom); University College London, Dementia Research Centre, Institute of Neurology, London (United Kingdom); Thielemans, Kris; Dickson, John [University College London, Institute of Nuclear Medicine, London (United Kingdom); Schott, Jonathan M. [University College London, Dementia Research Centre, Institute of Neurology, London (United Kingdom); Atkinson, David [University College London, Centre for Medical Imaging, London (United Kingdom); Arridge, Simon R. [University College London, Centre for Medical Image Computing, London (United Kingdom); Hutton, Brian F. [University College London, Institute of Nuclear Medicine, London (United Kingdom); University of Wollongong, Centre for Medical Radiation Physics, Wollongong, NSW (Australia)

    2015-08-15

    Positron Emission Tomography/Magnetic Resonance Imaging (PET/MR) scanners are expected to offer a new range of clinical applications. Attenuation correction is an essential requirement for quantification of PET data but MRI images do not directly provide a patient-specific attenuation map. Methods We further validate and extend a Computed Tomography (CT) and attenuation map (μ-map) synthesis method based on pre-acquired MRI-CT image pairs. The validation consists of comparing the CT images synthesised with the proposed method to the original CT images. PET images were acquired using two different tracers ({sup 18}F-FDG and {sup 18}F-florbetapir). They were then reconstructed and corrected for attenuation using the synthetic μ-maps and compared to the reference PET images corrected with the CT-based μ-maps. During the validation, we observed that the CT synthesis was inaccurate in areas such as the neck and the cerebellum, and propose a refinement to mitigate these problems, as well as an extension of the method to multi-contrast MRI data. Results With the improvements proposed, a significant enhancement in CT synthesis, which results in a reduced absolute error and a decrease in the bias when reconstructing PET images, was observed. For both tracers, on average, the absolute difference between the reference PET images and the PET images corrected with the proposed method was less than 2%, with a bias inferior to 1%. Conclusion With the proposed method, attenuation information can be accurately derived from MRI images by synthesising CT using routine anatomical sequences. MRI sequences, or combination of sequences, can be used to synthesise CT images, as long as they provide sufficient anatomical information. (orig.)

  1. ACE and ACTN3 genes polymorphisms among female Hungarian athletes in the aspect of sport disciplines.

    Science.gov (United States)

    Bosnyák, E; Trájer, E; Udvardy, A; Komka, Z; Protzner, A; Kováts, T; Györe, I; Tóth, M; Pucsok, J; Szmodis, M

    2015-12-01

    The aim of the study was to determine the importance of two sport-associated gene polymorphisms, alpha-actinin-3 R577X (ACTN3) and angiotensin-converting enzyme I/D (ACE), among Hungarian athletes in different sports. The examination was carried out only on women (n = 100). Sport-specific groups were formed in order to guarantee the most homogeneous clusters. Human genomic DNA was isolated from blood, and genotyping was performed by polymerase chain reaction. To measure the differences between the participating groups, Chi-squared test was performed using Statistica 9.0 for Windows® (significance level: p ACE I/D allele frequencies, significant difference was detected between water polo (I = 61.11%; D = 38.89%) and combat sports (I = 35.71%, D = 64.29%) athletes (p ACE I/D alleles in combat sports and kayaking/rowing (p > 0.05) were compared. A similarity was detectable in the I allele frequencies of the water polo (61.11%) and kayaking/rowing (56.67%) groups. The ACTN3 R/X polymorphism showed no differences in comparison with the sport groups. R allele frequencies were higher in every group compared to the X allele. The potential significance of the ACE I allele in sports of an aerobic nature was not clearly confirmed among Hungarian athletes.

  2. Quantitative Evaluation of Segmentation- and Atlas-Based Attenuation Correction for PET/MR on Pediatric Patients.

    Science.gov (United States)

    Bezrukov, Ilja; Schmidt, Holger; Gatidis, Sergios; Mantlik, Frédéric; Schäfer, Jürgen F; Schwenzer, Nina; Pichler, Bernd J

    2015-07-01

    Pediatric imaging is regarded as a key application for combined PET/MR imaging systems. Because existing MR-based attenuation-correction methods were not designed specifically for pediatric patients, we assessed the impact of 2 potentially influential factors: inter- and intrapatient variability of attenuation coefficients and anatomic variability. Furthermore, we evaluated the quantification accuracy of 3 methods for MR-based attenuation correction without (SEGbase) and with bone prediction using an adult and a pediatric atlas (SEGwBONEad and SEGwBONEpe, respectively) on PET data of pediatric patients. The variability of attenuation coefficients between and within pediatric (5-17 y, n = 17) and adult (27-66 y, n = 16) patient collectives was assessed on volumes of interest (VOIs) in CT datasets for different tissue types. Anatomic variability was assessed on SEGwBONEad/pe attenuation maps by computing mean differences to CT-based attenuation maps for regions of bone tissue, lungs, and soft tissue. PET quantification was evaluated on VOIs with physiologic uptake and on 80% isocontour VOIs with elevated uptake in the thorax and abdomen/pelvis. Inter- and intrapatient variability of the bias was assessed for each VOI group and method. Statistically significant differences in mean VOI Hounsfield unit values and linear attenuation coefficients between adult and pediatric collectives were found in the lungs and femur. The prediction of attenuation maps using the pediatric atlas showed a reduced error in bone tissue and better delineation of bone structure. Evaluation of PET quantification accuracy showed statistically significant mean errors in mean standardized uptake values of -14% ± 5% and -23% ± 6% in bone marrow and femur-adjacent VOIs with physiologic uptake for SEGbase, which could be reduced to 0% ± 4% and -1% ± 5% using SEGwBONEpe attenuation maps. Bias in soft-tissue VOIs was less than 5% for all methods. Lung VOIs showed high SDs in the range of 15% for

  3. Evaluation of 68Ga-DOTATOC PET/MRI for whole-body staging of neuroendocrine tumours in comparison with 68Ga-DOTATOC PET/CT

    International Nuclear Information System (INIS)

    Sawicki, Lino M.; Deuschl, Cornelius; Beiderwellen, Karsten; Forsting, Michael; Umutlu, Lale; Ruhlmann, Verena; Poeppel, Thorsten D.; Bockisch, Andreas; Herrmann, Ken; Heusch, Philipp; Antoch, Gerald; Lahner, Harald; Fuehrer, Dagmar

    2017-01-01

    To compare the diagnostic performance of 68 Ga-DOTATOC PET/MRI and 68 Ga-DOTATOC PET/CT in the whole-body staging of patients with neuroendocrine tumours (NET). Thirty patients with histopathologically confirmed NET underwent PET/CT and PET/MRI in a single-injection protocol. PET/CT and PET/MRI scans were prospectively evaluated with regard to lesion count, localization, nature (NET/non-NET), and conspicuity (four-point scale). Histopathology and follow-up imaging served as the reference standards. The proportions of NET and non-NET lesions rated correctly were compared using McNemar's chi-squared test. The Wilcoxon test was used to assess differences in SUVmax and lesion conspicuity. The correlation between the SUVmax for the same lesions from each modality was analysed using Pearson's correlation coefficient (r). According to the reference standard, there were 197 lesions (142 NET, 55 non-NET). Lesion-based analysis showed a higher proportion of correctly rated NET lesions on PET/MRI than on PET/CT (90.8% vs. 86.7%, p = 0.031), whereas on PET/CT there was a higher proportion of correctly rated non-NET lesions (94.5% vs. 83.6%, p = 0.031). SUVmax was strongly correlated (r = 0.86; p < 0.001) and did not differ significantly (p = 0.35) between the modalities. Overall conspicuity and NET lesion conspicuity were higher on PET/MRI (both p < 0.01). Ga-DOTATOC PET/MRI yielded a higher proportion of correctly rated NET lesions and should be regarded as a valuable alternative to 68 Ga-DOTATOC PET/CT in whole-body staging of NET patients. (orig.)

  4. Evaluating radon loss from water during storage in standard PET, bio-based PET, and PLA bottles

    International Nuclear Information System (INIS)

    Lucchetti, Carlo; De Simone, Gabriele; Galli, Gianfranco; Tuccimei, Paola

    2016-01-01

    Polyethylene terephthalate (PET) and polylactic acid (PLA) bottles were tested to evaluate radon loss from water during 15 days of storage. PET bottles (lower surface/volume-ratio vials) lost 0.4–7.1% of initial radon, whereas PLA bottles lost 3.7% of it. PET bottles with volume of 0.5 L, lower surface/weight ratio, and hence higher thickness display proportionally reduced radon loss. Corrections for dissolved radium are needed during analyses. Formulas for calculating degassing efficiency and water interference on electrostatic collections are developed. - Highlights: • Radon loss from water during storage in polyethylene terephthalate (PET) and polylactic acid (PLA) bottles was evaluated. • Surface/volume ratio and thickness of plastic materials were studied. • A correction for dissolved radium concentration was applied to estimate gas loss. • Proper corrections for degassing efficiency of aerators were developed. • The interference of H 2 O on radon daughter electrostatic collection was quantified.

  5. The ACE-DTU Planar Near-Field Ground Penetrating Radar Antenna Test Facility

    DEFF Research Database (Denmark)

    Lenler-Eriksen, Hans-Rudolph; Meincke, Peter

    2004-01-01

    The ACE-DTU planar near-field ground penetrating radar (GPR) antenna test facility is used to measure the plane-wave transmitting spectrum of a GPR loop antenna close to the air-soil interface by means of a probe buried in soil. Probe correction is implemented using knowledge about the complex...

  6. Impact of CT attenuation correction method on quantitative respiratory-correlated (4D) PET/CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nyflot, Matthew J., E-mail: nyflot@uw.edu [Department of Radiation Oncology, University of Washington, Seattle, Washington 98195-6043 (United States); Lee, Tzu-Cheng [Department of Bioengineering, University of Washington, Seattle, Washington 98195-6043 (United States); Alessio, Adam M.; Kinahan, Paul E. [Department of Radiology, University of Washington, Seattle, Washington 98195-6043 (United States); Wollenweber, Scott D.; Stearns, Charles W. [GE Healthcare, Waukesha, Wisconsin 53188 (United States); Bowen, Stephen R. [Department of Radiation Oncology, University of Washington, Seattle, Washington 98195-6043 and Department of Radiology, University of Washington, Seattle, Washington 98195-6043 (United States)

    2015-01-15

    Purpose: Respiratory-correlated positron emission tomography (PET/CT) 4D PET/CT is used to mitigate errors from respiratory motion; however, the optimal CT attenuation correction (CTAC) method for 4D PET/CT is unknown. The authors performed a phantom study to evaluate the quantitative performance of CTAC methods for 4D PET/CT in the ground truth setting. Methods: A programmable respiratory motion phantom with a custom movable insert designed to emulate a lung lesion and lung tissue was used for this study. The insert was driven by one of five waveforms: two sinusoidal waveforms or three patient-specific respiratory waveforms. 3DPET and 4DPET images of the phantom under motion were acquired and reconstructed with six CTAC methods: helical breath-hold (3DHEL), helical free-breathing (3DMOT), 4D phase-averaged (4DAVG), 4D maximum intensity projection (4DMIP), 4D phase-matched (4DMATCH), and 4D end-exhale (4DEXH) CTAC. Recovery of SUV{sub max}, SUV{sub mean}, SUV{sub peak}, and segmented tumor volume was evaluated as RC{sub max}, RC{sub mean}, RC{sub peak}, and RC{sub vol}, representing percent difference relative to the static ground truth case. Paired Wilcoxon tests and Kruskal–Wallis ANOVA were used to test for significant differences. Results: For 4DPET imaging, the maximum intensity projection CTAC produced significantly more accurate recovery coefficients than all other CTAC methods (p < 0.0001 over all metrics). Over all motion waveforms, ratios of 4DMIP CTAC recovery were 0.2 ± 5.4, −1.8 ± 6.5, −3.2 ± 5.0, and 3.0 ± 5.9 for RC{sub max}, RC{sub peak}, RC{sub mean}, and RC{sub vol}. In comparison, recovery coefficients for phase-matched CTAC were −8.4 ± 5.3, −10.5 ± 6.2, −7.6 ± 5.0, and −13.0 ± 7.7 for RC{sub max}, RC{sub peak}, RC{sub mean}, and RC{sub vol}. When testing differences between phases over all CTAC methods and waveforms, end-exhale phases were significantly more accurate (p = 0.005). However, these differences were driven by

  7. Deep-inspiration breath-hold PET/CT versus free breathing PET/CT and respiratory gating PET for reference. Evaluation in 95 patients with lung cancer

    International Nuclear Information System (INIS)

    Kawano, Tsuyoshi; Ohtake, Eiji; Inoue, Tomio

    2011-01-01

    The objective of this study was to define the factors that correlate with differences in maximum standardized uptake value (SUV max ) in deep-inspiration breath-hold (DIBH) and free breathing (FB) positron emission tomography (PET)/CT admixed with respiratory gating (RG) PET for reference. Patients (n=95) with pulmonary lesions were evaluated at one facility over 33 months. After undergoing whole-body PET/CT, a RG PET and FB PET/CT scans were obtained, followed by a DIBH PET/CT scan. All scans were recorded using a list-mode dynamic collection method with respiratory gating. The RG PET was reconstructed using phase gating without attenuation correction; the FB PET was reconstructed from the RG PET sinogram datasets with attenuation correction. Respiratory motion distance, breathing cycle speed, and waveform of RG PET were recorded. The SUV max of FB PET/CT and DIBH PET/CT were recorded: the percent difference in SUV max between the FB and DIBH scans was defined as the %BH-index. The %BH-index was significantly higher for lesions in the lower lung area than in the upper lung area. Respiratory motion distance was significantly higher in the lower lung area than in the upper lung area. A significant relationship was observed between the %BH-index and respiratory motion distance. Waveforms without steady end-expiration tended to show a high %BH-index. Significant inverse relationships were observed between %BH-index and cycle speed, and between respiratory motion distance and cycle speed. Decrease in SUV max of FB PET/CT was due to tumor size, distribution of lower lung, long respiratory movement at slow breathing cycle speeds, and respiratory waveforms without steady end-expiration. (author)

  8. The Addenbrooke's Cognitive Examination Revised (ACE-R) and its sub-scores: normative values in an Italian population sample.

    Science.gov (United States)

    Siciliano, Mattia; Raimo, Simona; Tufano, Dario; Basile, Giuseppe; Grossi, Dario; Santangelo, Franco; Trojano, Luigi; Santangelo, Gabriella

    2016-03-01

    The Addenbrooke's Cognitive Examination Revised (ACE-R) is a rapid screening battery, including five sub-scales to explore different cognitive domains: attention/orientation, memory, fluency, language and visuospatial. ACE-R is considered useful in discriminating cognitively normal subjects from patients with mild dementia. The aim of present study was to provide normative values for ACE-R total score and sub-scale scores in a large sample of Italian healthy subjects. Five hundred twenty-six Italian healthy subjects (282 women and 246 men) of different ages (age range 20-93 years) and educational level (from primary school to university) underwent ACE-R and Montreal Cognitive Assessment (MoCA). Multiple linear regression analysis revealed that age and education significantly influenced performance on ACE-R total score and sub-scale scores. A significant effect of gender was found only in sub-scale attention/orientation. From the derived linear equation, a correction grid for raw scores was built. Inferential cut-offs score were estimated using a non-parametric technique and equivalent scores (ES) were computed. Correlation analysis showed a good significant correlation between ACE-R adjusted scores with MoCA adjusted scores (r = 0.612, p < 0.001). The present study provided normative data for the ACE-R in an Italian population useful for both clinical and research purposes.

  9. Comparison of the diagnostic accuracy of PET/MRI to PET/CT-acquired FDG brain exams for seizure focus detection: a prospective study

    Energy Technology Data Exchange (ETDEWEB)

    Paldino, Michael J.; Jones, Jeremy Y.; Mahmood, Nadia; Sher, Andrew; Hayatghaibi, Shireen; Seghers, Victor [Texas Children' s Hospital, Department of Radiology, Houston, TX (United States); Yang, Erica [SimonMed Imaging, Department of Radiology, Scottsdale, AZ (United States); Zhang, Wei [Texas Children' s Hospital, Outcomes and Impact Service, Houston, TX (United States); Krishnamurthy, Ramkumar [Nationwide Children' s Hospital, Department of Radiology, Columbus, OH (United States)

    2017-10-15

    There is great interest in positron emission tomography (PET)/magnetic resonance (MR) as a clinical tool due to its capacity to provide diverse diagnostic information in a single exam. The goal of this exam is to compare the diagnostic accuracy of PET/MR-acquired [F-18]2-fluoro-2-deoxyglucose (FDG) brain exams to that of PET/CT with respect to identifying seizure foci in children with localization-related epilepsy. Institutional Review Board approval and informed consent were obtained for this Health Insurance Portability and Accountability Act-compliant, prospective study. All patients referred for clinical FDG-PET/CT exams of the brain at our institution for a diagnosis of localization-related epilepsy were prospectively recruited to undergo an additional FDG-PET acquisition on a tandem PET/MR system. Attenuation-corrected FDG images acquired at PET/MR and PET/CT were interpreted independently by five expert readers. Readers were blinded to the scanner used for acquisition and attenuation correction as well as all other clinical and imaging data. A Likert scale scoring system (1-5) was used to assess image quality. The locale of seizure origin determined at multidisciplinary epilepsy surgery work rounds was considered the reference standard. Non-inferiority testing for paired data was used to compare the diagnostic accuracy of PET/MR to that of PET/CT. The final study population comprised 35 patients referred for a diagnosis of localization-related epilepsy (age range: 2-19 years; median: 11 years; 21 males, 14 females). Image quality did not differ significantly between the two modalities. The accuracy of PET/MR was not inferior to that of PET/CT for localization of a seizure focus (P=0.017). The diagnostic accuracy of FDG-PET images acquired on a PET/MR scanner and generated using MR-based attenuation correction was not inferior to that of PET images processed by traditional CT-based correction. (orig.)

  10. Comparison of the diagnostic accuracy of PET/MRI to PET/CT-acquired FDG brain exams for seizure focus detection: a prospective study

    International Nuclear Information System (INIS)

    Paldino, Michael J.; Jones, Jeremy Y.; Mahmood, Nadia; Sher, Andrew; Hayatghaibi, Shireen; Seghers, Victor; Yang, Erica; Zhang, Wei; Krishnamurthy, Ramkumar

    2017-01-01

    There is great interest in positron emission tomography (PET)/magnetic resonance (MR) as a clinical tool due to its capacity to provide diverse diagnostic information in a single exam. The goal of this exam is to compare the diagnostic accuracy of PET/MR-acquired [F-18]2-fluoro-2-deoxyglucose (FDG) brain exams to that of PET/CT with respect to identifying seizure foci in children with localization-related epilepsy. Institutional Review Board approval and informed consent were obtained for this Health Insurance Portability and Accountability Act-compliant, prospective study. All patients referred for clinical FDG-PET/CT exams of the brain at our institution for a diagnosis of localization-related epilepsy were prospectively recruited to undergo an additional FDG-PET acquisition on a tandem PET/MR system. Attenuation-corrected FDG images acquired at PET/MR and PET/CT were interpreted independently by five expert readers. Readers were blinded to the scanner used for acquisition and attenuation correction as well as all other clinical and imaging data. A Likert scale scoring system (1-5) was used to assess image quality. The locale of seizure origin determined at multidisciplinary epilepsy surgery work rounds was considered the reference standard. Non-inferiority testing for paired data was used to compare the diagnostic accuracy of PET/MR to that of PET/CT. The final study population comprised 35 patients referred for a diagnosis of localization-related epilepsy (age range: 2-19 years; median: 11 years; 21 males, 14 females). Image quality did not differ significantly between the two modalities. The accuracy of PET/MR was not inferior to that of PET/CT for localization of a seizure focus (P=0.017). The diagnostic accuracy of FDG-PET images acquired on a PET/MR scanner and generated using MR-based attenuation correction was not inferior to that of PET images processed by traditional CT-based correction. (orig.)

  11. Whole-body PET/MRI: The effect of bone attenuation during MR-based attenuation correction in oncology imaging

    Energy Technology Data Exchange (ETDEWEB)

    Aznar, M.C., E-mail: marianne.aznar@regionh.dk [Department of Oncology, Section of Radiotherapy 3994, Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen (Denmark); Sersar, R., E-mail: rachidadk@hotmail.com [DTU Informatics, Technical University of Denmark, Kongens Lyngby (Denmark); Saabye, J., E-mail: julie_saa@hotmail.com [DTU Informatics, Technical University of Denmark, Kongens Lyngby (Denmark); Ladefoged, C.N., E-mail: claesnl@gmail.com [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); Andersen, F.L., E-mail: Flemming.Andersen@regionh.dk [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); Rasmussen, J.H., E-mail: jacobrasmu@gmail.com [Department of Oncology, Section of Radiotherapy 3994, Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen (Denmark); Löfgren, J., E-mail: Johan.Loefgren@regionh.dk [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); Beyer, T., E-mail: thomas.beyer@meduniwien.ac.at [Centre for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna (Austria)

    2014-07-15

    Purpose: In combined PET/MRI standard PET attenuation correction (AC) is based on tissue segmentation following dedicated MR sequencing and, typically, bone tissue is not represented. We evaluate PET quantification in whole-body (WB)-PET/MRI following MR-AC without considering bone attenuation and then investigate different strategies to account for bone tissue in clinical PET/MR imaging. To this purpose, bone tissue representation was extracted from separate CT images, and different bone representations were simulated from hypothetically derived MR-based bone classifications. Methods: Twenty oncology patients referred for a PET/CT were injected with either [18F]-FDG or [18F]-NaF and imaged on PET/CT (Biograph TruePoint/mCT, Siemens) and PET/MRI (mMR, Siemens) following a standard single-injection, dual-imaging clinical WB-protocol. Routine MR-AC was based on in-/opposed-phase MR imaging (orgMR-AC). PET(/MRI) images were reconstructed (AW-OSEM, 3 iterations, 21 subsets, 4 mm Gaussian) following routine MR-AC and MR-AC based on four modified attenuation maps. These modified attenuation maps were created for each patient by non-linear co-registration of the CT images to the orgMR-AC images, and adding CT bone mask values representing cortical bone: 1200 HU (cortCT), spongiosa bone: 350 HU (spongCT), average CT value (meanCT) and original CT values (orgCT). Relative difference images of the PET following AC using the modified attenuation maps were compared. SUVmean was calculated in anatomical reference regions and for PET-positive lesions. Results: The relative differences in SUVmean across patients following orgMR-AC and orgCT in soft tissue lesions and in bone lesions were similar (range: 0.0% to −22.5%), with an average underestimation of SUVmean of 7.2% and 10.0%, respectively when using orgMR-AC. In bone lesions, spongCT values were closest to orgCT (median bias of 1.3%, range: –9.0% to 13.5%) while the overestimation of SUVmean with respect to orgCT was

  12. Comparison of PET/CT with Sequential PET/MRI Using an MR-Compatible Mobile PET System.

    Science.gov (United States)

    Nakamoto, Ryusuke; Nakamoto, Yuji; Ishimori, Takayoshi; Fushimi, Yasutaka; Kido, Aki; Togashi, Kaori

    2018-05-01

    The current study tested a newly developed flexible PET (fxPET) scanner prototype. This fxPET system involves dual arc-shaped detectors based on silicon photomultipliers that are designed to fit existing MRI devices, allowing us to obtain fused PET and MR images by sequential PET and MR scanning. This prospective study sought to evaluate the image quality, lesion detection rate, and quantitative values of fxPET in comparison with conventional whole-body (WB) PET and to assess the accuracy of registration. Methods: Seventeen patients with suspected or known malignant tumors were analyzed. Approximately 1 h after intravenous injection of 18 F-FDG, WB PET/CT was performed, followed by fxPET and MRI. For reconstruction of fxPET images, MRI-based attenuation correction was applied. The quality of fxPET images was visually assessed, and the number of detected lesions was compared between the 2 imaging methods. SUV max and maximum average SUV within a 1 cm 3 spheric volume (SUV peak ) of lesions were also compared. In addition, the magnitude of misregistration between fxPET and MR images was evaluated. Results: The image quality of fxPET was acceptable for diagnosis of malignant tumors. There was no significant difference in detectability of malignant lesions between fxPET and WB PET ( P > 0.05). However, the fxPET system did not exhibit superior performance to the WB PET system. There were strong positive correlations between the 2 imaging modalities in SUV max (ρ = 0.88) and SUV peak (ρ = 0.81). SUV max and SUV peak measured with fxPET were approximately 1.1-fold greater than measured with WB PET. The average misregistration between fxPET and MR images was 5.5 ± 3.4 mm. Conclusion: Our preliminary data indicate that running an fxPET scanner near an existing MRI system provides visually and quantitatively acceptable fused PET/MR images for diagnosis of malignant lesions. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  13. The influence of the ACE (I/D) polymorphism on systemic and renal vascular responses to angiotensins in normotensive, normoalbuminuric Type 1 diabetes mellitus

    NARCIS (Netherlands)

    Luik, PT; Hoogenberg, K; Kerstens, MN; Beusekamp, BJ; de Jong, PE; Dullaart, RPF; Navis, GJ

    Aim/hypothesis. The renin-angiotensin-aldosterone system is important in diabetic nephropathy, with the angiotensin-converting-enzyme DD-genotype being a renal risk factor. The D-allele is associated with higher ACE concentrations, but functional consequences in diabetes mellitus are not known. To

  14. ACES CONTINUOUS DATA V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The ALTUS Cloud Electrification Study (ACES) was Based at the Naval Air Facility Key West in Florida. ACES researchers in August 2002 conducted overflights of...

  15. ACES CONTINUOUS DATA V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The ALTUS Cloud Electrification Study (ACES) was based at the Naval Air Facility Key West in Florida. During August, 2002, ACES researchers conducted overflights of...

  16. ACES TRIGGERED DATA V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The ALTUS Cloud Electrification Study (ACES) was based at the Naval Air Facility Key West in Florida. During August 2002, ACES researchers conducted overflights of...

  17. ACES TIMING DATA V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The ALTUS Cloud Electrification Study (ACES) was based at the Naval Air Facility Key West in Florida. During August or 2002, ACES researchers overflights of...

  18. ACES TRIGGERED DATA V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The ALTUS Cloud Electrification Study (ACES) was Based at the Naval Air Facility Key West in Florida. ACES researchers in August 2002 conducted overflights of...

  19. ACES LOG DATA V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The ALTUS Cloud Electrification Study (ACES) was Based at the Naval Air Facility Key West in Florida. ACES researchers in August 2002 conducted overflights of...

  20. ACES TIMING DATA V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The ALTUS Cloud Electrification Study (ACES) was Based at the Naval Air Facility Key West in Florida. ACES researchers in August 2002 conducted overflights of...

  1. Evaluation of {sup 68}Ga-DOTATOC PET/MRI for whole-body staging of neuroendocrine tumours in comparison with {sup 68}Ga-DOTATOC PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Sawicki, Lino M. [University Dusseldorf, Department of Diagnostic and Interventional Radiology, Medical Faculty, Dusseldorf (Germany); University Duisburg-Essen, Department of Nuclear Medicine, Medical Faculty, Essen (Germany); Deuschl, Cornelius; Beiderwellen, Karsten; Forsting, Michael; Umutlu, Lale [University Duisburg-Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Medical Faculty, Essen (Germany); Ruhlmann, Verena; Poeppel, Thorsten D.; Bockisch, Andreas; Herrmann, Ken [University Duisburg-Essen, Department of Nuclear Medicine, Medical Faculty, Essen (Germany); Heusch, Philipp; Antoch, Gerald [University Dusseldorf, Department of Diagnostic and Interventional Radiology, Medical Faculty, Dusseldorf (Germany); Lahner, Harald; Fuehrer, Dagmar [University Duisburg-Essen, Department of Endocrinology and Metabolism, Endocrine Tumour Center at WTZ and ENETS Center of Excellence, Medical Faculty, Essen (Germany); Endocrine Tumour Center at WTZ and ENETS Center of Excellence, Essen (Germany)

    2017-10-15

    To compare the diagnostic performance of {sup 68}Ga-DOTATOC PET/MRI and {sup 68}Ga-DOTATOC PET/CT in the whole-body staging of patients with neuroendocrine tumours (NET). Thirty patients with histopathologically confirmed NET underwent PET/CT and PET/MRI in a single-injection protocol. PET/CT and PET/MRI scans were prospectively evaluated with regard to lesion count, localization, nature (NET/non-NET), and conspicuity (four-point scale). Histopathology and follow-up imaging served as the reference standards. The proportions of NET and non-NET lesions rated correctly were compared using McNemar's chi-squared test. The Wilcoxon test was used to assess differences in SUVmax and lesion conspicuity. The correlation between the SUVmax for the same lesions from each modality was analysed using Pearson's correlation coefficient (r). According to the reference standard, there were 197 lesions (142 NET, 55 non-NET). Lesion-based analysis showed a higher proportion of correctly rated NET lesions on PET/MRI than on PET/CT (90.8% vs. 86.7%, p = 0.031), whereas on PET/CT there was a higher proportion of correctly rated non-NET lesions (94.5% vs. 83.6%, p = 0.031). SUVmax was strongly correlated (r = 0.86; p < 0.001) and did not differ significantly (p = 0.35) between the modalities. Overall conspicuity and NET lesion conspicuity were higher on PET/MRI (both p < 0.01). Ga-DOTATOC PET/MRI yielded a higher proportion of correctly rated NET lesions and should be regarded as a valuable alternative to {sup 68}Ga-DOTATOC PET/CT in whole-body staging of NET patients. (orig.)

  2. Angiotensinogen and ACE gene polymorphisms and risk of atrial fibrillation in the general population

    DEFF Research Database (Denmark)

    Ravn, Lasse S; Benn, Marianne; Nordestgaard, Børge G

    2008-01-01

    OBJECTIVES: The renin-angiotensin system may play a role in the pathogenesis of atrial fibrillation, and renin-angiotensin system blockers reduce the risk of atrial fibrillation. We hypothesized that polymorphisms in the angiotensinogen and angiotensin-converting enzyme (ACE) genes encoding...... in the ACE gene; rare allele frequencies were 0.16, 0.40, 0.12, 0.41, and 0.49, respectively. Participants had sinus rhythm at inclusion. During 26 years of follow-up, 968 individuals developed atrial fibrillation. Multifactorially adjusted hazard ratios for atrial fibrillation for a-20c ac and cc versus aa...... proteins in this system predict risk of atrial fibrillation. METHODS AND RESULTS: We genotyped 9235 individuals from the Danish general population, The Copenhagen City Heart Study, for the a-20c, g-6a, T174M, and M235T polymorphisms in the angiotensinogen gene and the insertion/deletion (I/D) polymorphism...

  3. Whole-body biodistribution, dosimetry and metabolite correction of [11C]palmitate: A PET tracer for imaging of fatty acid metabolism

    DEFF Research Database (Denmark)

    Christensen, Nana Louise; Jakobsen, Steen; Schacht, Anna Christina

    2017-01-01

    release and parent [11C]palmitate measured by a solid-phase extraction (SPE) method. Finally, myocardial fatty acid uptake was calculated in a patient cohort using input functions derived from individual metabolite correction compared with population-based metabolite correction. RESULTS: In humans, mean......INTRODUCTION: Despite the decades long use of [11C]palmitate positron emission tomography (PET)/computed tomography in basic metabolism studies, only personal communications regarding dosimetry and biodistribution data have been published. METHODS: Dosimetry and biodistribution studies were...

  4. PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients.

    Science.gov (United States)

    Burger, C; Goerres, G; Schoenes, S; Buck, A; Lonn, A H R; Von Schulthess, G K

    2002-07-01

    The CT data acquired in combined PET/CT studies provide a fast and essentially noiseless source for the correction of photon attenuation in PET emission data. To this end, the CT values relating to attenuation of photons in the range of 40-140 keV must be transformed into linear attenuation coefficients at the PET energy of 511 keV. As attenuation depends on photon energy and the absorbing material, an accurate theoretical relation cannot be devised. The transformation implemented in the Discovery LS PET/CT scanner (GE Medical Systems, Milwaukee, Wis.) uses a bilinear function based on the attenuation of water and cortical bone at the CT and PET energies. The purpose of this study was to compare this transformation with experimental CT values and corresponding PET attenuation coefficients. In 14 patients, quantitative PET attenuation maps were calculated from germanium-68 transmission scans, and resolution-matched CT images were generated. A total of 114 volumes of interest were defined and the average PET attenuation coefficients and CT values measured. From the CT values the predicted PET attenuation coefficients were calculated using the bilinear transformation. When the transformation was based on the narrow-beam attenuation coefficient of water at 511 keV (0.096 cm(-1)), the predicted attenuation coefficients were higher in soft tissue than the measured values. This bias was reduced by replacing 0.096 cm(-1) in the transformation by the linear attenuation coefficient of 0.093 cm(-1) obtained from germanium-68 transmission scans. An analysis of the corrected emission activities shows that the resulting transformation is essentially equivalent to the transmission-based attenuation correction for human tissue. For non-human material, however, it may assign inaccurate attenuation coefficients which will also affect the correction in neighbouring tissue.

  5. Reproducibility of Quantitative Brain Imaging Using a PET-Only and a Combined PET/MR System

    Directory of Open Access Journals (Sweden)

    Martin L. Lassen

    2017-07-01

    Full Text Available The purpose of this study was to test the feasibility of migrating a quantitative brain imaging protocol from a positron emission tomography (PET-only system to an integrated PET/MR system. Potential differences in both absolute radiotracer concentration as well as in the derived kinetic parameters as a function of PET system choice have been investigated. Five healthy volunteers underwent dynamic (R-[11C]verapamil imaging on the same day using a GE-Advance (PET-only and a Siemens Biograph mMR system (PET/MR. PET-emission data were reconstructed using a transmission-based attenuation correction (AC map (PET-only, whereas a standard MR-DIXON as well as a low-dose CT AC map was applied to PET/MR emission data. Kinetic modeling based on arterial blood sampling was performed using a 1-tissue-2-rate constant compartment model, yielding kinetic parameters (K1 and k2 and distribution volume (VT. Differences for parametric values obtained in the PET-only and the PET/MR systems were analyzed using a 2-way Analysis of Variance (ANOVA. Comparison of DIXON-based AC (PET/MR with emission data derived from the PET-only system revealed average inter-system differences of −33 ± 14% (p < 0.05 for the K1 parameter and −19 ± 9% (p < 0.05 for k2. Using a CT-based AC for PET/MR resulted in slightly lower systematic differences of −16 ± 18% for K1 and −9 ± 10% for k2. The average differences in VT were −18 ± 10% (p < 0.05 for DIXON- and −8 ± 13% for CT-based AC. Significant systematic differences were observed for kinetic parameters derived from emission data obtained from PET/MR and PET-only imaging due to different standard AC methods employed. Therefore, a transfer of imaging protocols from PET-only to PET/MR systems is not straightforward without application of proper correction methods.Clinical Trial Registration:www.clinicaltrialsregister.eu, identifier 2013-001724-19

  6. The ACE experiment

    CERN Multimedia

    Maximilien Brice

    2006-01-01

    The Antiproton Cell Experiment (ACE) as shown by Michael Holzscheiter (spokesperson), Niels Bassler (co-spokesperson) and Helge Knudsen. ACE is located on the Antiproton Decelerator (AD) at CERN. An antiproton annihilates a proton in the nucleus of a cancer cell, producing a pair of gamma rays, destroying the entire cell and some surrounding cells. Many fewer antiprotons are required in this treatment than in the equivalent proton hadron therapy, so there is less risk of healthy tissue damage.

  7. Pathological Ace2-to-Ace enzyme switch in the stressed heart is transcriptionally controlled by the endothelial Brg1–FoxM1 complex

    Science.gov (United States)

    Yang, Jin; Feng, Xuhui; Zhou, Qiong; Cheng, Wei; Shang, Ching; Han, Pei; Lin, Chiou-Hong; Chen, Huei-Sheng Vincent; Quertermous, Thomas; Chang, Ching-Pin

    2016-01-01

    Genes encoding angiotensin-converting enzymes (Ace and Ace2) are essential for heart function regulation. Cardiac stress enhances Ace, but suppresses Ace2, expression in the heart, leading to a net production of angiotensin II that promotes cardiac hypertrophy and fibrosis. The regulatory mechanism that underlies the Ace2-to-Ace pathological switch, however, is unknown. Here we report that the Brahma-related gene-1 (Brg1) chromatin remodeler and forkhead box M1 (FoxM1) transcription factor cooperate within cardiac (coronary) endothelial cells of pathologically stressed hearts to trigger the Ace2-to-Ace enzyme switch, angiotensin I-to-II conversion, and cardiac hypertrophy. In mice, cardiac stress activates the expression of Brg1 and FoxM1 in endothelial cells. Once activated, Brg1 and FoxM1 form a protein complex on Ace and Ace2 promoters to concurrently activate Ace and repress Ace2, tipping the balance to Ace2 expression with enhanced angiotensin II production, leading to cardiac hypertrophy and fibrosis. Disruption of endothelial Brg1 or FoxM1 or chemical inhibition of FoxM1 abolishes the stress-induced Ace2-to-Ace switch and protects the heart from pathological hypertrophy. In human hypertrophic hearts, BRG1 and FOXM1 expression is also activated in endothelial cells; their expression levels correlate strongly with the ACE/ACE2 ratio, suggesting a conserved mechanism. Our studies demonstrate a molecular interaction of Brg1 and FoxM1 and an endothelial mechanism of modulating Ace/Ace2 ratio for heart failure therapy. PMID:27601681

  8. [ACE inhibitors and the kidney].

    Science.gov (United States)

    Hörl, W H

    1996-01-01

    Treatment with ACE inhibitors results in kidney protection due to reduction of systemic blood pressure, intraglomerular pressure, an antiproliferative effect, reduction of proteinuria and a lipid-lowering effect in proteinuric patients (secondary due to reduction of protein excretion). Elderly patients with diabetes melitus, coronary heart disease or peripheral vascular occlusion are at risk for deterioration of kidney function due to a high frequency of renal artery stenosis in these patients. In patients with renal insufficiency dose reduction of ACE inhibitors is necessary (exception: fosinopril) but more important is the risk for development of hyperkalemia. Patients at risk for renal artery stenosis and patients pretreated with diuretics should receive a low ACE inhibitor dosage initially ("start low - go slow"). For compliance reasons once daily ACE inhibitor dosage is recommended.

  9. ACE2 Global Digital Elevation Model : User Analysis

    Science.gov (United States)

    Smith, R. G.; Berry, P. A. M.; Benveniste, J.

    2013-12-01

    Altimeter Corrected Elevations 2 (ACE2), first released in October 2009, is the Global Digital Elevation Model (GDEM) created by fusing the high accuracy of over 100 million altimeter retracked height estimates, derived primarily from the ERS-1 Geodetic Mission, with the high frequency content available within the near-global Shuttle Radar Topography Mission. This novel ACE2 GDEM is freely available at 3”, 9”, 30” and 5' and has been distributed via the web to over 680 subscribers. This paper presents the results of a detailed analysis of geographical distribution of subscribed users, along with fields of study and potential uses. Investigations have also been performed to determine the most popular spatial resolutions and the impact these have on the scope of data downloaded. The analysis has shown that, even though the majority of users have come from Europe and America, a significant number of website hits have been received from South America, Africa and Asia. Registered users also vary widely, from research institutions and major companies down to individual hobbyists looking at data for single projects.

  10. Thoracic staging in lung cancer: prospective comparison of 18F-FDG PET/MR imaging and 18F-FDG PET/CT.

    Science.gov (United States)

    Heusch, Philipp; Buchbender, Christian; Köhler, Jens; Nensa, Felix; Gauler, Thomas; Gomez, Benedikt; Reis, Henning; Stamatis, Georgios; Kühl, Hilmar; Hartung, Verena; Heusner, Till A

    2014-03-01

    Therapeutic decisions in non-small cell lung cancer (NSCLC) patients depend on the tumor stage. PET/CT with (18)F-FDG is widely accepted as the diagnostic standard of care. The purpose of this study was to compare a dedicated pulmonary (18)F-FDG PET/MR imaging protocol with (18)F-FDG PET/CT for primary and locoregional lymph node staging in NSCLC patients using histopathology as the reference. Twenty-two patients (12 men, 10 women; mean age ± SD, 65.1 ± 9.1 y) with histopathologically confirmed NSCLC underwent (18)F-FDG PET/CT, followed by (18)F-FDG PET/MR imaging, including a dedicated pulmonary MR imaging protocol. T and N staging according to the seventh edition of the American Joint Committee on Cancer staging manual was performed by 2 readers in separate sessions for (18)F-FDG PET/CT and PET/MR imaging, respectively. Results from histopathology were used as the standard of reference. The mean and maximum standardized uptake value (SUV(mean) and SUV(max), respectively) and maximum diameter of the primary tumor was measured and compared in (18)F-FDG PET/CT and PET/MR imaging. PET/MR imaging and (18)F-FDG PET/CT agreed on T stages in 16 of 16 of patients (100%). All patients were correctly staged by (18)F-FDG PET/CT and PET/MR (100%), compared with histopathology. There was no statistically significant difference between (18)F-FDG PET/CT and (18)F-FDG PET/MR imaging for lymph node metastases detection (P = 0.48). For definition of thoracic N stages, PET/MR imaging and (18)F-FDG PET/CT were concordant in 20 of 22 patients (91%). PET/MR imaging determined the N stage correctly in 20 of 22 patients (91%). (18)F-FDG PET/CT determined the N stage correctly in 18 of 22 patients (82%). The mean differences for SUV(mean) and SUV(max) of NSCLC in (18)F-FDG PET/MR imaging and (18)F-FDG PET/CT were 0.21 and -5.06. These differences were not statistically significant (P > 0.05). The SUV(mean) and SUV(max) measurements derived from (18)F-FDG PET/CT and (18)F-FDG PET

  11. Quantitation of regional cerebral blood flow corrected for partial volume effect using O-15 water and PET

    DEFF Research Database (Denmark)

    IIda, H.; Law, I.; Pakkenberg, B.

    2000-01-01

    Limited spatial resolution of positron emission tomography (PET) can cause significant underestimation in the observed regional radioactivity concentration (so-called partial volume effect or PVE) resulting in systematic errors in estimating quantitative physiologic parameters. The authors have...... formulated four mathematical models that describe the dynamic behavior of a freely diffusible tracer (H215O) in a region of interest (ROI) incorporating estimates of regional tissue flow that are independent of PVE. The current study was intended to evaluate the feasibility of these models and to establish...... a methodology to accurately quantify regional cerebral blood flow (CBF) corrected for PVE in cortical gray matter regions. Five monkeys were studied with PET after IV H2(15)O two times (n = 3) or three times (n = 2) in a row. Two ROIs were drawn on structural magnetic resonance imaging (MRI) scans and projected...

  12. A method for partial volume correction of PET-imaged tumor heterogeneity using expectation maximization with a spatially varying point spread function

    International Nuclear Information System (INIS)

    Barbee, David L; Holden, James E; Nickles, Robert J; Jeraj, Robert; Flynn, Ryan T

    2010-01-01

    Tumor heterogeneities observed in positron emission tomography (PET) imaging are frequently compromised by partial volume effects which may affect treatment prognosis, assessment or future implementations such as biologically optimized treatment planning (dose painting). This paper presents a method for partial volume correction of PET-imaged heterogeneous tumors. A point source was scanned on a GE Discovery LS at positions of increasing radii from the scanner's center to obtain the spatially varying point spread function (PSF). PSF images were fit in three dimensions to Gaussian distributions using least squares optimization. Continuous expressions were devised for each Gaussian width as a function of radial distance, allowing for generation of the system PSF at any position in space. A spatially varying partial volume correction (SV-PVC) technique was developed using expectation maximization (EM) and a stopping criterion based on the method's correction matrix generated for each iteration. The SV-PVC was validated using a standard tumor phantom and a tumor heterogeneity phantom and was applied to a heterogeneous patient tumor. SV-PVC results were compared to results obtained from spatially invariant partial volume correction (SINV-PVC), which used directionally uniform three-dimensional kernels. SV-PVC of the standard tumor phantom increased the maximum observed sphere activity by 55 and 40% for 10 and 13 mm diameter spheres, respectively. Tumor heterogeneity phantom results demonstrated that as net changes in the EM correction matrix decreased below 35%, further iterations improved overall quantitative accuracy by less than 1%. SV-PVC of clinically observed tumors frequently exhibited changes of ±30% in regions of heterogeneity. The SV-PVC method implemented spatially varying kernel widths and automatically determined the number of iterations for optimal restoration, parameters which are arbitrarily chosen in SINV-PVC. Comparing SV-PVC to SINV-PVC demonstrated

  13. Issues in quantification of registered respiratory gated PET/CT in the lung

    Science.gov (United States)

    Cuplov, Vesna; Holman, Beverley F.; McClelland, Jamie; Modat, Marc; Hutton, Brian F.; Thielemans, Kris

    2018-01-01

    PET/CT quantification of lung tissue is limited by several difficulties: the lung density and local volume changes during respiration, the anatomical mismatch between PET and CT and the relative contributions of tissue, air and blood to the PET signal (the tissue fraction effect). Air fraction correction (AFC) has been shown to improve PET image quantification in the lungs. Methods to correct for the movement and anatomical mismatch involve respiratory gating and image registration techniques. While conventional registration methods only account for spatial mismatch, the Jacobian determinant of the deformable registration transformation field can be used to estimate local volume changes and could therefore potentially be used to correct (i.e. Jacobian Correction, JC) the PET signal for changes in concentration due to local volume changes. This work aims to investigate the relationship between variations in the lung due to respiration, specifically density, tracer concentration and local volume changes. In particular, we study the effect of AFC and JC on PET quantitation after registration of respiratory gated PET/CT patient data. Six patients suffering from lung cancer with solitary pulmonary nodules underwent 18 F-FDG PET/cine-CT. The PET data were gated into six respiratory gates using displacement gating based on a real-time position management (RPM) signal and reconstructed with matched gated CT. The PET tracer concentration and tissue density were extracted from registered gated PET and CT images before and after corrections (AFC or JC) and compared to the values from the reference images. Before correction, we observed a linear correlation between the PET tracer concentration values and density. Across all gates and patients, the maximum relative change in PET tracer concentration before (after) AFC was found to be 16.2% (4.1%) and the maximum relative change in tissue density and PET tracer concentration before (after) JC was found to be 17.1% (5.5%) and 16

  14. Angiotensin converting enzyme genotype affects development and course of sarcoidosis in Asian Indians.

    Science.gov (United States)

    Tahir, Mohammad; Sharma, S K; Ashraf, Shazia; Mishra, Hemant K

    2007-09-01

    Studies of serum angiotensin converting enzyme (SACE) activity and its association with ACE gene insertion/deletion (I/D) polymorphism in relation to sarcoidosis have yielded variable results. This has been attributed to possible ethnic differences. Present study was designed to evaluate the relationship between I/D polymorphism and susceptibility to develop sarcoidosis and its effect on SACE activity and disease course in Asian Indian patients with sarcoidosis. ACE genotyping was performed in 72 consecutive patients with sarcoidosis and 199 controls (96 normal healthy individuals and 103 tuberculosis patients taken as disease controls). SACE activity was determined in all patients with sarcoidosis. Various parameters were compared amongst patients with different genotypes as well as between sarcoidosis and control groups. Gene frequency of I and D in control group was 0.6 and 0.4, whereas in patients with sarcoidosis it was 0.35 and 0.65 respectively (p SACE activity was highest in patients with DD genotype and followed an order of DD > ID > II. Good response to initial corticosteroids was seen in 6 of 6 (100%) patients with II genotype whereas in only 32 of 37 (84%) with ID and 16 of 25 (64%) with DD (p = 0.013). In Asian Indian population 'D' allele is associated with an increased risk for development of sarcoidosis and patients with 'D' allele show poor response to corticosteroids.

  15. Considerations and code for partial volume correcting [18F]-AV-1451 tau PET data

    Directory of Open Access Journals (Sweden)

    Suzanne L. Baker

    2017-12-01

    Full Text Available [18F]-AV-1451 is a leading tracer used with positron emission tomography (PET to quantify tau pathology. However, [18F]-AV-1451 shows “off target” or non-specific binding, which we define as binding of the tracer in unexpected areas unlikely to harbor aggregated tau based on autopsy literature [1]. Along with caudate, putamen, pallidum and thalamus non-specific binding [2,3], we have found binding in the superior portion of the cerebellar gray matter, leading us to use inferior cerebellar gray as the reference region. We also addressed binding in the posterior portion of the choroid plexus. PET signal unlikely to be associated with tau also occurs in skull, meninges and soft tissue (see e.g. [4]. We refer to [18F]-AV-1451 binding in the skull and meninges as extra-cortical hotspots (ECH and find them near lateral and medial orbitofrontal, lateral occipital, inferior and middle temporal, superior and inferior parietal, and inferior cerebellar gray matter. Lastly, the choroid plexus also shows non-specific binding that bleeds into hippocampus. We are providing the code (http://www.runmycode.org/companion/view/2798 used to create different regions of interest (ROIs that we then used to perform Partial Volume Correction (PVC using the Rousset geometric transfer matrix method (GTM, [5]. This method was used in the companion article, “Comparison of multiple tau-PET measures as biomarkers in aging and Alzheimer's Disease” ([6], DOI 10.1016/j.neuroimage.2017.05.058.

  16. FDG PET and CT in locally advanced adenocarcinomas of the distal oesophagus. Clinical relevance of a discordant PET finding

    International Nuclear Information System (INIS)

    Stahl, A.; Wieder, H.; Schwaiger, M.; Weber, W.A.; Stollfuss, J.; Ott, K.; Fink, U.

    2005-01-01

    Aim: the incidence of adenocarcinomas of the distal oesophagus (ADE) has dramatically increased in Western countries. The clinical importance of a FDG PET finding discordant with CT was determined in patients with locally advanced ADE. In addition, tumour standardized uptake values (SUV) were correlated with patient survival. Patients, methods: 40 consecutive patients were analyzed retrospectively. All patients underwent an attenuation corrected FDG PET scan (neck, chest, abdomen) and contrast enhanced helical CT of the chest and abdomen. PET and CT scans were reviewed independently and concomitantly with respect to metastases in predefined lymph node sites and organs. Any discordance between PET and CT was assessed for clinical relevance. Clinical relevance was defined as a change in the overall therapeutic concept (curative vs. palliative). Follow-up imaging and histological evaluation served as the gold standard. Mean tumour SUVs were determined by 1.5 cm regions of interest placed over the tumour's maximum. Results: when read independently from the CT scan FDG PET indicated a clinically relevant change in tumour stage in 9/40 patients (23%) and a non-relevant change in 11/40 patients (28%). PET was correct in 5/9 patients (56%) with clinically relevant discordances. In 4/9 patients PET was incorrect (3 false positive due to suspicion of MI-lymph nodes or lung metastases, 1 false negative in disseminated liver metastases). With concomitant reading, PET indicated a clinically relevant change in tumour stage in 6/40 patients (15%) and a non-relevant change in 5/40 patients (13%). PET was correct in 5/6 patients (83%) with clinically relevant discordances. The patient with disseminated liver disease remained the single false negative. Overall, the benefit from PET was based on its higher diagnostic accuracy at organ sites. Tumour SUV did not correlate with patient survival. Conclusion: about half of discordances between FDG PET and CT are clinically relevant

  17. RESOLUTE PET/MRI Attenuation Correction for O-(2-18F-fluoroethyl-L-tyrosine (FET in Brain Tumor Patients with Metal Implants

    Directory of Open Access Journals (Sweden)

    Claes N. Ladefoged

    2017-08-01

    Full Text Available Aim: Positron emission tomography (PET imaging is a useful tool for assisting in correct differentiation of tumor progression from reactive changes, and the radiolabeled amino acid analog tracer O-(2-18F-fluoroethyl-L-tyrosine (FET-PET is amongst the most frequently used. The FET-PET images need to be quantitatively correct in order to be used clinically, which require accurate attenuation correction (AC in PET/MRI. The aim of this study was to evaluate the use of the subject-specific MR-derived AC method RESOLUTE in post-operative brain tumor patients.Methods: We analyzed 51 post-operative brain tumor patients (68 examinations, 200 MBq [18F]-FET investigated in a PET/MRI scanner. MR-AC maps were acquired using: (1 the Dixon water fat separation sequence, (2 the ultra short echo time (UTE sequences, (3 calculated using our new RESOLUTE methodology, and (4 a same day low-dose CT used as reference “gold standard.” For each subject and each AC method the tumor was delineated by isocontouring tracer uptake above a tumor(T-to-brain background (B activity ratio of 1.6. We measured B, tumor mean and maximal activity (TMEAN, TMAX, biological tumor volume (BTV, and calculated the clinical metrics TMEAN/B and TMAX/B.Results: When using RESOLUTE 5/68 studies did not meet our predefined acceptance criteria of TMAX/B difference to CT-AC < ±0.1 or 5%, TMEAN/B < ±0.05 or 5%, and BTV < ±2 mL or 10%. In total, 46/68 studies failed our acceptance criteria using Dixon, and 26/68 using UTE. The 95% limits of agreement for TMAX/B was for RESOLUTE (−3%; 4%, Dixon (−9%; 16%, and UTE (−7%; 10%. The absolute error when measuring BTV was 0.7 ± 1.9 mL (N.S with RESOLUTE, 5.3 ± 10 mL using Dixon, and 1.7 ± 3.7 mL using UTE. RESOLUTE performed best in the identification of the location of peak activity and in brain tumor follow-up monitoring using clinical FET PET metrics.Conclusions: Overall, we found RESOLUTE to be the AC method that most robustly

  18. ASSOCIATION OF ACTN3 R577X AND ACE I/D POLYMORPHISMS IN BRAZILIANS WRESTLERS

    OpenAIRE

    Ribas, Marcelo Romanovitch; Oliveira Netto, Zair Candido; Salgueirosa, Fabiano; Fernandes, Priscila; Matos, Oslei de; Bassan, Julio Cesar

    2017-01-01

    ABSTRACT Introduction: By associating genetics and sport, it is possible to identify subjects with greater capacity to adapt to training, and lower chances of injury. Objective: The investigation evaluated the genotypic and allelic distribution of ACTN3 R577X and ACE I/D polymorphisms in Brazilian high-performance athletes in wrestling and percussion combat sports. Methods: The study included 37 male athletes ranked from first to third place in world scenarios, divided into two groups: wrestl...

  19. 76 FR 37136 - Post-Summary Corrections to Entry Summaries Filed in ACE Pursuant to the ESAR IV Test

    Science.gov (United States)

    2011-06-24

    ... accelerated liquidation request indicator. C. Electronic Data Interface (EDI) Capability Trade participants.../ace_edi_messages/catair_main/abi_catair . Operational documentation addressing PSC may be found in the...

  20. Importance of Attenuation Correction (AC) for Small Animal PET Imaging

    DEFF Research Database (Denmark)

    El Ali, Henrik H.; Bodholdt, Rasmus Poul; Jørgensen, Jesper Tranekjær

    2012-01-01

    was performed. Methods: Ten NMRI nude mice with subcutaneous implantation of human breast cancer cells (MCF-7) were scanned consecutively in small animal PET and CT scanners (MicroPETTM Focus 120 and ImTek’s MicroCATTM II). CT-based AC, PET-based AC and uniform AC methods were compared. Results: The activity...

  1. RESOLUTE PET/MRI Attenuation Correction for O-(2-F-fluoroethyl)-L-tyrosine (FET) in Brain Tumor Patients with Metal Implants

    DEFF Research Database (Denmark)

    Ladefoged, Claes N; Andersen, Flemming L; Kjær, Andreas

    2017-01-01

    of agreement for TMAX/B was for RESOLUTE (-3%; 4%), Dixon (-9%; 16%), and UTE (-7%; 10%). The absolute error when measuring BTV was 0.7 ± 1.9 mL (N.S) with RESOLUTE, 5.3 ± 10 mL using Dixon, and 1.7 ± 3.7 mL using UTE. RESOLUTE performed best in the identification of the location of peak activity and in brain...... to be quantitatively correct in order to be used clinically, which require accurate attenuation correction (AC) in PET/MRI. The aim of this study was to evaluate the use of the subject-specific MR-derived AC method RESOLUTE in post-operative brain tumor patients.Methods:We analyzed 51 post-operative brain tumor...... patients (68 examinations, 200 MBq [18F]-FET) investigated in a PET/MRI scanner. MR-AC maps were acquired using: (1) the Dixon water fat separation sequence, (2) the ultra short echo time (UTE) sequences, (3) calculated using our new RESOLUTE methodology, and (4) a same day low-dose CT used as reference...

  2. ACE3P Computations of Wakefield Coupling in the CLIC Two-Beam Accelerator

    International Nuclear Information System (INIS)

    Candel, Arno

    2010-01-01

    The Compact Linear Collider (CLIC) provides a path to a multi-TeV accelerator to explore the energy frontier of High Energy Physics. Its novel two-beam accelerator concept envisions rf power transfer to the accelerating structures from a separate high-current decelerator beam line consisting of power extraction and transfer structures (PETS). It is critical to numerically verify the fundamental and higher-order mode properties in and between the two beam lines with high accuracy and confidence. To solve these large-scale problems, SLAC's parallel finite element electromagnetic code suite ACE3P is employed. Using curvilinear conformal meshes and higher-order finite element vector basis functions, unprecedented accuracy and computational efficiency are achieved, enabling high-fidelity modeling of complex detuned structures such as the CLIC TD24 accelerating structure. In this paper, time-domain simulations of wakefield coupling effects in the combined system of PETS and the TD24 structures are presented. The results will help to identify potential issues and provide new insights on the design, leading to further improvements on the novel CLIC two-beam accelerator scheme.

  3. A meta-analysis of the accuracy of the Addenbrooke's Cognitive Examination (ACE) and the Addenbrooke's Cognitive Examination-Revised (ACE-R) in the detection of dementia.

    Science.gov (United States)

    Larner, Andrew J; Mitchell, Alex J

    2014-04-01

    The Addenbrooke's Cognitive Examination (ACE) and its Revised version (ACE-R) are relatively new screening tools for cognitive impairment that may improve upon the well-known Mini-Mental State Examination (MMSE) and other brief batteries. We systematically reviewed diagnostic accuracy studies of ACE and ACE-R. Published studies comparing ACE, ACE-R and MMSE were comprehensively sought and critically appraised. A meta-analysis of suitable studies was conducted. Of 61 possible publications identified, meta-analysis of qualifying studies encompassed 5 for ACE (1,090 participants) and 5 for ACE-R (1156 participants); of these, 9 made direct comparisons with the MMSE. Sensitivity and specificity of the ACE were 96.9% (95% CI = 92.7% to 99.4%) and 77.4% (95% CI = 58.3% to 91.8%); and for the ACE-R were 95.7% (95% CI = 92.2% to 98.2%) and 87.5% (95% CI = 63.8% to 99.4%). In a modest prevalence setting, such as primary care or general hospital settings where the prevalence of dementia may be approximately 25%, overall accuracy of the ACE (0.823) was inferior to ACE-R (0.895) and MMSE (0.882). In high prevalence settings such as memory clinics where the prevalence of dementia may be 50% or higher, overall accuracy again favored ACE-R (0.916) over ACE (0.872) and MMSE (0.895). The ACE-R has somewhat superior diagnostic accuracy to the MMSE while the ACE appears to have inferior accuracy. The ACE-R is recommended in both modest and high prevalence settings. Accuracy of newer versions of the ACE remain to be determined.

  4. Cryptosporidium spp. in pet birds: genetic diversity and potential public health significance.

    Science.gov (United States)

    Qi, Meng; Wang, Rongjun; Ning, Changshen; Li, Xiaoyu; Zhang, Longxian; Jian, Fuchun; Sun, Yanru; Xiao, Lihua

    2011-08-01

    To characterize the prevalence and assess the zoonotic transmission burden of Cryptosporidium species/genotypes in pet birds in Henan, China, 434 fecal samples were acquired from 14 families of birds in pet shops. The overall prevalence of Cryptopsoridium was 8.1% (35/434) by the Sheather's sugar flotation technique. The Cryptosporidium-positive samples were analyzed by DNA sequence analysis of the small subunit (SSU) rRNA gene. Three Cryptosporidium species and two genotypes were identified, including C. baileyi (18/35 or 51.4%) in five red-billed leiothrixes (Leiothrix lutea), four white Java sparrows (Padda oryzivora), four common mynas (Acridotheres tristis), two zebra finches (Taeniopygia guttata), a crested Lark (Galerida cristata), a Gouldian finch (Chloebia gouldiae), and a black-billed magpie (Pica pica); Cryptosporidium meleagridis (3/35 or 8.6%) in a Bohemian waxwing (Bombycilla garrulus), a Rufous turtle dove (Streptopelia orientalis), and a fan-tailed pigeon (Columba livia); Cryptosporidium galli (5/35 or 14.3%) in four Bohemian waxwings (Bombycilla garrulus) and a silver-eared Mesia (Leiothrix argentauris); Cryptosporidium avian genotype III (3/35 or 8.6%) in two cockatiels (Nymphicus hollandicus) and a red-billed blue magpie (Urocissa erythrorhyncha); and Cryptosporidium avian genotype V (6/35 or 17.1%) in six cockatiels (Nymphicus hollandicus). Among the pet birds, 12 species represented new hosts for Cryptosporidum infections. The presence of C. meleagridis raises questions on potential zoonotic transmission of cryptosporidiosis from pet birds to humans. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. Do carotid MR surface coils affect PET quantification in PET/MR imaging?

    International Nuclear Information System (INIS)

    Willemink, Martin J; Eldib, Mootaz; Leiner, Tim; Fayad, Zahi A; Mani, Venkatesh

    2015-01-01

    To evaluate the effect of surface coils for carotid MR imaging on PET quantification in a clinical simultaneous whole-body PET/MR scanner. A cylindrical phantom was filled with a homogeneous 2L water-FDG mixture at a starting dose of 301.2MBq. Clinical PET/MR and PET/CT systems were used to acquire PET-data without a coil (reference standard) and with two carotid MRI coils (Siemens Special Purpose 8-Channel and Machnet 4-Channel Phased Array). PET-signal attenuation was evaluated with Osirix using 51 (PET/MR) and 37 (PET/CT) circular ROIs. Mean and maximum standardized uptake values (SUVs) were quantified for each ROI. Furthermore, SUVs of PET/MR and PET/CT were compared. For validation, a patient was scanned with an injected dose of 407.7MBq on both a PET/CT and a PET/MR system without a coil and with both coils. PET/MR underestimations were -2.2% (Siemens) and -7.8% (Machnet) for SUVmean, and -1.2% (Siemens) and -3.3% (Machnet) for SUVmax, respectively. For PET/CT, underestimations were -1.3% (Siemens) and -1.4% (Machnet) for SUVmean and -0.5% (both Siemens and Machnet) for SUVmax, respectively using no coil data as reference. Except for PET/CT SUVmax values all differences were significant. SUVs differed significantly between PET/MR and PET/CT with SUVmean values of 0.51-0.55 for PET/MR and 0.68-0.69 for PET/CT, respectively. The patient examination showed that median SUVmean values measured in the carotid arteries decreased from 0.97 without a coil to 0.96 (Siemens) and 0.88 (Machnet). Carotid surface coils do affect attenuation correction in both PET/MR and PET/CT imaging. Furthermore, SUVs differed significantly between PET/MR and PET/CT.

  6. A dual-Kinect approach to determine torso surface motion for respiratory motion correction in PET

    International Nuclear Information System (INIS)

    Heß, Mirco; Büther, Florian; Dawood, Mohammad; Schäfers, Klaus P.; Gigengack, Fabian

    2015-01-01

    Purpose: Respiratory gating is commonly used to reduce blurring effects and attenuation correction artifacts in positron emission tomography (PET). Established clinically available methods that employ body-attached hardware for acquiring respiration signals rely on the assumption that external surface motion and internal organ motion are well correlated. In this paper, the authors present a markerless method comprising two Microsoft Kinects for determining the motion on the whole torso surface and aim to demonstrate its validity and usefulness—including the potential to study the external/internal correlation and to provide useful information for more advanced correction approaches. Methods: The data of two Kinects are used to calculate 3D representations of a patient’s torso surface with high spatial coverage. Motion signals can be obtained for any position by tracking the mean distance to a virtual camera with a view perpendicular to the surrounding surface. The authors have conducted validation experiments including volunteers and a moving high-precision platform to verify the method’s suitability for providing meaningful data. In addition, the authors employed it during clinical 18 F-FDG-PET scans and exemplarily analyzed the acquired data of ten cancer patients. External signals of abdominal and thoracic regions as well as data-driven signals were used for gating and compared with respect to detected displacement of present lesions. Additionally, the authors quantified signal similarities and time shifts by analyzing cross-correlation sequences. Results: The authors’ results suggest a Kinect depth resolution of approximately 1 mm at 75 cm distance. Accordingly, valid signals could be obtained for surface movements with small amplitudes in the range of only few millimeters. In this small sample of ten patients, the abdominal signals were better suited for gating the PET data than the thoracic signals and the correlation of data-driven signals was found

  7. A dual-Kinect approach to determine torso surface motion for respiratory motion correction in PET

    Energy Technology Data Exchange (ETDEWEB)

    Heß, Mirco, E-mail: mirco.hess@uni-muenster.de; Büther, Florian; Dawood, Mohammad; Schäfers, Klaus P. [European Institute for Molecular Imaging, University of Münster, Münster 48149 (Germany); Gigengack, Fabian [European Institute for Molecular Imaging, University of Münster, Münster 48149, Germany and Department of Mathematics and Computer Science, University of Münster, Münster 48149 (Germany)

    2015-05-15

    Purpose: Respiratory gating is commonly used to reduce blurring effects and attenuation correction artifacts in positron emission tomography (PET). Established clinically available methods that employ body-attached hardware for acquiring respiration signals rely on the assumption that external surface motion and internal organ motion are well correlated. In this paper, the authors present a markerless method comprising two Microsoft Kinects for determining the motion on the whole torso surface and aim to demonstrate its validity and usefulness—including the potential to study the external/internal correlation and to provide useful information for more advanced correction approaches. Methods: The data of two Kinects are used to calculate 3D representations of a patient’s torso surface with high spatial coverage. Motion signals can be obtained for any position by tracking the mean distance to a virtual camera with a view perpendicular to the surrounding surface. The authors have conducted validation experiments including volunteers and a moving high-precision platform to verify the method’s suitability for providing meaningful data. In addition, the authors employed it during clinical {sup 18}F-FDG-PET scans and exemplarily analyzed the acquired data of ten cancer patients. External signals of abdominal and thoracic regions as well as data-driven signals were used for gating and compared with respect to detected displacement of present lesions. Additionally, the authors quantified signal similarities and time shifts by analyzing cross-correlation sequences. Results: The authors’ results suggest a Kinect depth resolution of approximately 1 mm at 75 cm distance. Accordingly, valid signals could be obtained for surface movements with small amplitudes in the range of only few millimeters. In this small sample of ten patients, the abdominal signals were better suited for gating the PET data than the thoracic signals and the correlation of data-driven signals was

  8. ACES ELECTRIC FIELD MILL V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The ALTUS Cloud Electrification Study (ACES) was based at the Naval Air Facility Key West in Florida. ACES researchers in August 2002 conducted overflights of...

  9. PET/TAC: Basic principles, physiological variants and artifacts; PET/TAC: Generalidades, variantes fisiologicas y artefactos

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez V, A.M. [Especialista en Medicina Nuclear, Profa. Depto. Radiologia de la Facultad de Medicina, Universidad Complutense de Madrid, Madrid (Spain)

    2007-07-01

    This presentation is about the basic principles, physiologic variants and devices that work in the PET/TAC technique. Next the conclusions obtained in the same one are presented: For a correct evaluation of the PET/TAC images with FDG is necessary the knowledge of the image acquisition technique, as well as of the physiologic distribution of the FDG, variants of the normality, benign causes of captation and more frequent devices. The introduction of this hybrid procedure allows the correct anatomical localization and identification of the deposits of FDG largely avoiding false or doubtful interpretations, but it can also originate not specific devices existent in the conventional PET. The previous knowledge of the possible devices will make possible in certain cases its elimination and in other its identification avoiding incorrect interpretations. (Author)

  10. Beginning RPG Maker VX Ace

    CERN Document Server

    Perez, Darrin

    2014-01-01

    Beginning RPG Maker VX Ace takes you through the process of using the RPG Maker VX Ace game development engine to create your very own role playing game. The book has been designed with the complete beginner in mind who has little to no experience with the engine. Tutorials and exercises will take you from installing the software to putting the final touches upon your first project. Game design can be quite a daunting challenge, as it generally involves a large amount of programming know-how on top of having to plan everything out that makes a good game what it is. RPG Maker VX Ace

  11. Direct reconstruction of parametric images for brain PET with event-by-event motion correction: evaluation in two tracers across count levels

    Science.gov (United States)

    Germino, Mary; Gallezot, Jean-Dominque; Yan, Jianhua; Carson, Richard E.

    2017-07-01

    Parametric images for dynamic positron emission tomography (PET) are typically generated by an indirect method, i.e. reconstructing a time series of emission images, then fitting a kinetic model to each voxel time activity curve. Alternatively, ‘direct reconstruction’, incorporates the kinetic model into the reconstruction algorithm itself, directly producing parametric images from projection data. Direct reconstruction has been shown to achieve parametric images with lower standard error than the indirect method. Here, we present direct reconstruction for brain PET using event-by-event motion correction of list-mode data, applied to two tracers. Event-by-event motion correction was implemented for direct reconstruction in the Parametric Motion-compensation OSEM List-mode Algorithm for Resolution-recovery reconstruction. The direct implementation was tested on simulated and human datasets with tracers [11C]AFM (serotonin transporter) and [11C]UCB-J (synaptic density), which follow the 1-tissue compartment model. Rigid head motion was tracked with the Vicra system. Parametric images of K 1 and distribution volume (V T  =  K 1/k 2) were compared to those generated by the indirect method by regional coefficient of variation (CoV). Performance across count levels was assessed using sub-sampled datasets. For simulated and real datasets at high counts, the two methods estimated K 1 and V T with comparable accuracy. At lower count levels, the direct method was substantially more robust to outliers than the indirect method. Compared to the indirect method, direct reconstruction reduced regional K 1 CoV by 35-48% (simulated dataset), 39-43% ([11C]AFM dataset) and 30-36% ([11C]UCB-J dataset) across count levels (averaged over regions at matched iteration); V T CoV was reduced by 51-58%, 54-60% and 30-46%, respectively. Motion correction played an important role in the dataset with larger motion: correction increased regional V T by 51% on average in the [11C

  12. Reduced plasma levels of angiotensin-(1-7 and renin activity in preeclamptic patients are associated with the angiotensin I- converting enzyme deletion/deletion genotype

    Directory of Open Access Journals (Sweden)

    E.P. Velloso

    2007-04-01

    Full Text Available The relationship between preeclampsia and the renin-angiotensin system (RAS is poorly understood. Angiotensin I-converting enzyme (ACE is a key RAS component and plays an important role in blood pressure homeostasis by generating angiotensin II (Ang II and inactivating the vasodilator angiotensin-(1-7 (Ang-(1-7. ACE (I/D polymorphism is characterized by the insertion (I or deletion (D of a 287-bp fragment, leading to changes in ACE activity. In the present study, ACE (I/D polymorphism was correlated with plasma Ang-(1-7 levels and several RAS components in both preeclamptic (N = 20 and normotensive pregnant women (N = 20. The percentage of the ACE DD genotype (60% in the preeclamptic group was higher than that for the control group (35%; however, this percentage was not statistically significant (Fisher exact test = 2.86, d.f. = 2, P = 0.260. The highest plasma ACE activity was observed in the ACE DD preeclamptic women (58.1 ± 5.06 vs 27.6 ± 3.25 nmol Hip-His Leu-1 min-1 mL-1 in DD control patients; P = 0.0005. Plasma renin activity was markedly reduced in preeclampsia (0.81 ± 0.2 vs 3.43 ± 0.8 ng Ang I mL plasma-1 h-1 in DD normotensive patients; P = 0.0012. A reduced plasma level of Ang-(1-7 was also observed in preeclamptic women (15.6 ± 1.3 vs 22.7 ± 2.5 pg/mL in the DD control group; P = 0.0146. In contrast, plasma Ang II levels were unchanged in preeclamptic patients. The selective changes in the RAS described in the present study suggest that the ACE DD genotype may be used as a marker for susceptibility to preeclampsia.

  13. Reduced plasma levels of angiotensin-(1-7 and renin activity in preeclamptic patients are associated with the angiotensin I- converting enzyme deletion/deletion genotype

    Directory of Open Access Journals (Sweden)

    E.P. Velloso

    Full Text Available The relationship between preeclampsia and the renin-angiotensin system (RAS is poorly understood. Angiotensin I-converting enzyme (ACE is a key RAS component and plays an important role in blood pressure homeostasis by generating angiotensin II (Ang II and inactivating the vasodilator angiotensin-(1-7 (Ang-(1-7. ACE (I/D polymorphism is characterized by the insertion (I or deletion (D of a 287-bp fragment, leading to changes in ACE activity. In the present study, ACE (I/D polymorphism was correlated with plasma Ang-(1-7 levels and several RAS components in both preeclamptic (N = 20 and normotensive pregnant women (N = 20. The percentage of the ACE DD genotype (60% in the preeclamptic group was higher than that for the control group (35%; however, this percentage was not statistically significant (Fisher exact test = 2.86, d.f. = 2, P = 0.260. The highest plasma ACE activity was observed in the ACE DD preeclamptic women (58.1 ± 5.06 vs 27.6 ± 3.25 nmol Hip-His Leu-1 min-1 mL-1 in DD control patients; P = 0.0005. Plasma renin activity was markedly reduced in preeclampsia (0.81 ± 0.2 vs 3.43 ± 0.8 ng Ang I mL plasma-1 h-1 in DD normotensive patients; P = 0.0012. A reduced plasma level of Ang-(1-7 was also observed in preeclamptic women (15.6 ± 1.3 vs 22.7 ± 2.5 pg/mL in the DD control group; P = 0.0146. In contrast, plasma Ang II levels were unchanged in preeclamptic patients. The selective changes in the RAS described in the present study suggest that the ACE DD genotype may be used as a marker for susceptibility to preeclampsia.

  14. ACE and UCP2 gene polymorphisms and their association with baseline and exercise-related changes in the functional performance of older adults

    Directory of Open Access Journals (Sweden)

    Justin W.L. Keogh

    2015-05-01

    Full Text Available Maintaining high levels of physical function is an important aspect of successful ageing. While muscle mass and strength contribute to functional performance in older adults, little is known about the possible genetic basis for the heterogeneity of physical function in older adults and in how older adults respond to exercise. Two genes that have possible roles in determining levels of muscle mass, strength and function in young and older adults are angiotensin-converting enzyme (ACE and mitochondrial uncoupling protein 2 (UCP2. This study examined whether polymorphisms in these two individual genes were associated with baseline functional performance levels and/or the training-related changes following exercise in previously untrained older adults. Five-eight Caucasian older adults (mean age 69.8 years with no recent history of resistance training enrolled in a 12 week program of resistance, balance and cardiovascular exercises aimed at improving functional performance. Performance in 6 functional tasks was recorded at baseline and after 12 weeks. Genomic DNA was assayed for the ACE intron 16 insertion/deletion (I/D and the UCP2 G-866A polymorphism. Baseline differences among genotype groups were tested using analysis of variance. Genotype differences in absolute and relative changes in physical function among the exercisers were tested using a general linear model, adjusting for age and gender. The genotype frequencies for each of the studied polymorphisms conformed to the Hardy-Weinberg equilibrium. The ACE I/D genotype was significantly associated with mean baseline measures of handgrip strength (II 30.9 ± 3.01 v. ID 31.7 ± 1.48 v. DD 29.3 ± 2.18 kg, p < 0.001, 8ft Up and Go time (II 6.45 ± 0.48 v. ID/DD 4.41 ± 0.19 s, p < 0.001 and 6 min walk distance (II 458 ± 28.7 v. ID/DD 546 ± 12.1m, p = 0.008. The UCP2 G-866A genotype was also associated with baseline 8ft Up and Go time (GG 5.45 ± 0.35 v. GA 4.47 ± 0.26 v. AA 3.89 ± 0.71 s, p

  15. User's manual ACE/ONED (Version 1.0)

    International Nuclear Information System (INIS)

    Lee, Ki Bok; Lee, Jeong Chan; Song, Jae Seung; Lee, Chang Kyu; Ji, Sung Kyun; Song, Jae Woong; Kim, Yong Rae; Chang, Jong Hwa

    1996-03-01

    This report explains installation of ACE/ONED code, structure of input and output, how to prepare input and introduces some sample inputs. ACE/ONED developed by KAERI is a two-group one-dimensional diffusion theory code for nuclear design and reactor simulations. The usage of ACE/ONED encompasses core follow calculation, load-following calculation, plant power control simulation, xenon oscillation simulation, control rod maneuvering, and so on. ACE/ONED programmed of FORTRAN 77 in most part can be run on almost all kinds of computer including personal computer. 4 tabs., 4 figs., 8 refs. (Author) .new

  16. Angiotensin converting enzyme insertion/deletion genotype, exercise and physical decline: evidence of a gene-environment interaction

    NARCIS (Netherlands)

    Kritchevsky, S.B.; Nicklas, B.J.; Visser, M.; Simonsick, E.M.; Newman, A.B.; Harris, T.B.; Lange, E.M.; Penninx, B.W.J.H.; Goodpaster, B.H.; Satterfield, S.; Colbert, L.; Rubin, S; Pahor, M.

    2005-01-01

    Context: Physical performance in response to exercise appears to be influenced by the angiotensin-converting enzyme (ACE) insertion (I)/deletion (D) genotype in young adults, but whether this relationship could help explain variation in older individuals' response to exercise has not been well

  17. Lysozyme and bilirubin bind to ACE and regulate its conformation and shedding

    Science.gov (United States)

    Danilov, Sergei M.; Lünsdorf, Heinrich; Akinbi, Henry T.; Nesterovitch, Andrew B.; Epshtein, Yuliya; Letsiou, Eleftheria; Kryukova, Olga V.; Piegeler, Tobias; Golukhova, Elena Z.; Schwartz, David E.; Dull, Randal O.; Minshall, Richard D.; Kost, Olga A.; Garcia, Joe G. N.

    2016-01-01

    Angiotensin I-converting enzyme (ACE) hydrolyzes numerous peptides and is a critical participant in blood pressure regulation and vascular remodeling. Elevated tissue ACE levels are associated with increased risk for cardiovascular and respiratory disorders. Blood ACE concentrations are determined by proteolytic cleavage of ACE from the endothelial cell surface, a process that remains incompletely understood. In this study, we identified a novel ACE gene mutation (Arg532Trp substitution in the N domain of somatic ACE) that increases blood ACE activity 7-fold and interrogated the mechanism by which this mutation significantly increases blood ACE levels. We hypothesized that this ACE mutation disrupts the binding site for blood components which may stabilize ACE conformation and diminish ACE shedding. We identified the ACE-binding protein in the blood as lysozyme and also a Low Molecular Weight (LMW) ACE effector, bilirubin, which act in concert to regulate ACE conformation and thereby influence ACE shedding. These results provide mechanistic insight into the elevated blood level of ACE observed in patients on ACE inhibitor therapy and elevated blood lysozyme and ACE levels in sarcoidosis patients. PMID:27734897

  18. Impact of motion compensation and partial volume correction for 18F-NaF PET/CT imaging of coronary plaque

    Science.gov (United States)

    Cal-González, J.; Tsoumpas, C.; Lassen, M. L.; Rasul, S.; Koller, L.; Hacker, M.; Schäfers, K.; Beyer, T.

    2018-01-01

    Recent studies have suggested that 18F-NaF-PET enables visualization and quantification of plaque micro-calcification in the coronary tree. However, PET imaging of plaque calcification in the coronary arteries is challenging because of the respiratory and cardiac motion as well as partial volume effects. The objective of this work is to implement an image reconstruction framework, which incorporates compensation for respiratory as well as cardiac motion (MoCo) and partial volume correction (PVC), for cardiac 18F-NaF PET imaging in PET/CT. We evaluated the effect of MoCo and PVC on the quantification of vulnerable plaques in the coronary arteries. Realistic simulations (Biograph TPTV, Biograph mCT) and phantom acquisitions (Biograph mCT) were used for these evaluations. Different uptake values in the calcified plaques were evaluated in the simulations, while three ‘plaque-type’ lesions of 36, 31 and 18 mm3 were included in the phantom experiments. After validation, the MoCo and PVC methods were applied in four pilot NaF-PET patient studies. In all cases, the MoCo-based image reconstruction was performed using the STIR software. The PVC was obtained from a local projection (LP) method, previously evaluated in preclinical and clinical PET. The results obtained show a significant increase of the measured lesion-to-background ratios (LBR) in the MoCo  +  PVC images. These ratios were further enhanced when using directly the tissue-activities from the LP method, making this approach more suitable for the quantitative evaluation of coronary plaques. When using the LP method on the MoCo images, LBR increased between 200% and 1119% in the simulated data, between 212% and 614% in the phantom experiments and between 46% and 373% in the plaques with positive uptake observed in the pilot patients. In conclusion, we have built and validated a STIR framework incorporating MoCo and PVC for 18F-NaF PET imaging of coronary plaques. First results indicate an improved

  19. Evaluation of the PET component of simultaneous [18F]choline PET/MRI in prostate cancer: comparison with [18F]choline PET/CT

    International Nuclear Information System (INIS)

    Wetter, Axel; Lipponer, Christine; Nensa, Felix; Altenbernd, Jens-Christian; Schlosser, Thomas; Lauenstein, Thomas; Heusch, Philipp; Ruebben, Herbert; Bockisch, Andreas; Poeppel, Thorsten; Nagarajah, James

    2014-01-01

    The aim of this study was to evaluate the positron emission tomography (PET) component of [ 18 F]choline PET/MRI and compare it with the PET component of [ 18 F]choline PET/CT in patients with histologically proven prostate cancer and suspected recurrent prostate cancer. Thirty-six patients were examined with simultaneous [ 18 F]choline PET/MRI following combined [ 18 F]choline PET/CT. Fifty-eight PET-positive lesions in PET/CT and PET/MRI were evaluated by measuring the maximum and mean standardized uptake values (SUV max and SUV mean ) using volume of interest (VOI) analysis. A scoring system was applied to determine the quality of the PET images of both PET/CT and PET/MRI. Agreement between PET/CT and PET/MRI regarding SUV max and SUV mean was tested using Pearson's product-moment correlation and Bland-Altman analysis. All PET-positive lesions that were visible on PET/CT were also detectable on PET/MRI. The quality of the PET images was comparable in both groups. Median SUV max and SUV mean of all lesions were significantly lower in PET/MRI than in PET/CT (5.2 vs 6.1, p max of PET/CT and PET/MRI (R = 0.86, p mean of PET/CT and PET/MRI (R = 0.81, p max of PET/CT vs PET/MRI and -1.12 to +2.23 between SUV mean of PET/CT vs PET/MRI. PET image quality of PET/MRI was comparable to that of PET/CT. A highly significant correlation between SUV max and SUV mean was found. Both SUV max and SUV mean were significantly lower in [ 18 F]choline PET/MRI than in [ 18 F]choline PET/CT. Differences of SUV max and SUV mean might be caused by different techniques of attenuation correction. Furthermore, differences in biodistribution and biokinetics of [ 18 F]choline between the subsequent examinations and in the respective organ systems have to be taken into account. (orig.)

  20. Hydronephrosis alters cardiac ACE2 and Mas receptor expression in mice.

    Science.gov (United States)

    Zhang, Yanling; Ma, Lulu; Wu, Junyan; Chen, Tingting

    2015-06-01

    Hydronephrosis is characterized by substantial loss of tubules and affects renin secretion in the kidney. However, whether alterations of angiotensin-converting enzyme (ACE), ACE2 and Mas receptor in the heart are observed in hydronephrosis is unknown. Thus, we assessed these components in hydronephrotic mice treated with AT1 receptor blockade and ACE inhibitor. Hydronephrosis was induced by left ureteral ligation in Balb/C mice except sham-operated animals. The levels of cardiac ACE, ACE2 and Mas receptor were measured after treatment of losartan or enalapril. Hydronephrosis led to an increase of ACE level and a decrease of ACE2 and Mas receptor in the heart. Losartan decreased cardiac ACE level, but ACE2 and Mas receptor levels significantly increased in hydronephrotic mice (p Hydronephrosis increased cardiac ACE and suppressed ACE2 and Mas receptor levels. AT1 blockade caused sustained activation of cardiac ACE2 and Mas receptor, but ACE inhibitor had the limitation of such activation of Mas receptor in hydronephrotic animals. © The Author(s) 2015.

  1. Metallic artifacts caused by dental metal prostheses on PET images. A PET/CT phantom study using different PET/CT scanners

    International Nuclear Information System (INIS)

    Shimamoto, Hiroaki; Kakimoto, Naoya; Murakami, Shumei; Furukawa, Souhei; Fujino, Kouichi; Hamada, Seiki; Shimosegawa, Eku; Hatazawa, Jun

    2009-01-01

    The objective of this study was to investigate the effects of computed tomography (CT) artifacts caused by dental metal prostheses on positron emission tomography (PET) images. A dental arch cast was fixed in a cylindrical water-bath phantom. A spherical phantom positioned in the vicinity of the dental arch cast was used to simulate a tumor. To simulate the tumor imaging, the ratio of the 18 F-fluoro-deoxy-glucose radioactivity concentration of the spherical phantom to that of the water-bath phantom was set at 2.5. A dental bridge composed of a gold-silver-palladium alloy on the right mandibular side was prepared. A spherical phantom was set in the white artifact area on the CT images (site A), in a slightly remote area from the white artifact (site B), and in a black artifact area (site C). A PET/CT scan was performed with and without the metal bridge at each simulated tumor site, and the artifactual influence was evaluated on the axial attenuation-corrected (AC) PET images, in which the simulated tumor produced the strongest accumulation. Measurements were performed using three types of PET/CT scanners (scanners 1 and 2 with CT-based attenuation correction, and 3 with Cesium-137 ( 137 Cs)-based attenuation correction). The influence of the metal bridge was evaluated using the change rate of the SUVmean with and without the metal bridge. At site A, an overestimation was shown (scanner 1: +5.0% and scanner 2: +2.5%), while scanner 3 showed an underestimation of -31.8%. At site B, an overestimation was shown (scanner 1: +2.1% and scanner 2: +2.0%), while scanner 3 showed an underestimation of -2.6%. However, at site C, an underestimation was shown (scanner 1: -25.0%, scanner 2: -32.4%, and scanner 3: -8.4%). When CT is used for attenuation correction in patients with dental metal prostheses, an underestimation of radioactivity of accumulated tracer is anticipated in the dark streak artifact area on the CT images. In this study, the dark streak artifacts of the CT

  2. Understanding Antegrade Colonic Enema (ACE) Surgery

    Science.gov (United States)

    ... Enema (ACE) Surgery Menu Overview Procedure Details Risks / Benefits What is antegrade colonic enema (ACE) surgery? Antegrade ... Accepted Insurance Make a Donation Refer a Patient Phone Directory Blog, News & Mobile Apps Consult QD Health Essentials Newsroom Mobile Apps ...

  3. Side-by-side reading of PET and CT scans in oncology: Which patients might profit from integrated PET/CT?

    International Nuclear Information System (INIS)

    Reinartz, Patrick; Wieres, Franz-Josef; Schneider, Wolfram; Schur, Alexander; Buell, Ulrich

    2004-01-01

    Most early publications on integrated positron emission tomography/computed tomography (PET/CT) devices have reported the new scanner generation to be superior to conventional PET. However, few of these studies have analysed the situation where, in addition to PET, a current CT scan is available for side-by-side viewing. This fact is important, because combined PET/CT or a software-based fusion of the two modalities may improve diagnosis only in cases where side-by-side reading of PET and CT data does not lead to a definitive diagnosis. The aim of this study was to analyse which patients will profit from integrated PET/CT in terms of lesion characterization. A total of 328 consecutively admitted patients referred for PET in whom a current CT scan was available were included in the study. The localization of all pathological PET lesions, as well as possible infiltration of adjacent anatomical structures, was assessed. Of 467 pathological lesions, 94.0% were correctly assessed with respect to localization and infiltration by either conventional PET alone (51.6%) or combined reading of PET and the already existing CT scans (42.4%). Hence, in only 6.0% of all lesions, affecting 6.7% of all patients, could evaluation have profited from integrated PET/CT. We conclude that side-by-side viewing of PET and CT scans is essential, as in 42.4% of all cases, combined viewing was important for a correct diagnosis in our series. In up to 6.7% of patients, integrated PET/CT might have given additional information, so that in nearly 50% of patients some form of combined viewing of PET and CT data is needed for accurate lesion characterization. (orig.)

  4. Chronic Treatment with Ang-(1-7 Reverses Abnormal Reactivity in the Corpus Cavernosum and Normalizes Diabetes-Induced Changes in the Protein Levels of ACE, ACE2, ROCK1, ROCK2 and Omega-Hydroxylase in a Rat Model of Type 1 Diabetes

    Directory of Open Access Journals (Sweden)

    Mariam H. M. Yousif

    2014-01-01

    Full Text Available Angiotensin-(1-7 [Ang-(1-7] may have beneficial effects in diabetes mellitus-induced erectile dysfunction (DMIED but its molecular actions in the diabetic corpus cavernosum (CC are not known. We characterized the effects of diabetes and/or chronic in vivo administration of Ang-(1-7 on vascular reactivity in the rat corpus cavernosum (CC and on protein expression levels of potential downstream effectors of the renin-angiotensin-aldosterone system (RAAS such as angiotensin-converting enzyme (ACE, ACE2, Rho kinases 1 and 2 (ROCK1 and ROCK2, and omega-hydroxylase, the cytochrome-P450 enzyme that metabolizes arachidonic acid to form the vasoconstrictor, 20-hydroxyeicosatetraenoic acid. Streptozotocin-treated rats were chronicically administered Ang-(1-7 with or without A779, a Mas receptor antagonist, during weeks 4 to 6 of diabetes. Ang-(1-7 reversed diabetes-induced abnormal reactivity to vasoactive agents (endothelin-1, phenylepherine, and carbachol in the CC without correcting hyperglycemia. Six weeks of diabetes led to elevated ACE, ROCK1, ROCK 2, and omega-hydroxylase and a concomitant decrease in ACE2 protein expression levels that were normalized by Ang-(1-7 treatment but not upon coadministration of A779. These data are supportive of the notion that the beneficial effects of Ang-(1-7 in DMIED involve counterregulation of diabetes-induced changes in ACE, ACE2, Rho kinases, and omega-hydroxylase proteins in the diabetic CC via a Mas receptor-dependent mechanism.

  5. Motion correction of PET brain images through deconvolution: I. Theoretical development and analysis in software simulations

    Science.gov (United States)

    Faber, T. L.; Raghunath, N.; Tudorascu, D.; Votaw, J. R.

    2009-02-01

    Image quality is significantly degraded even by small amounts of patient motion in very high-resolution PET scanners. Existing correction methods that use known patient motion obtained from tracking devices either require multi-frame acquisitions, detailed knowledge of the scanner, or specialized reconstruction algorithms. A deconvolution algorithm has been developed that alleviates these drawbacks by using the reconstructed image to estimate the original non-blurred image using maximum likelihood estimation maximization (MLEM) techniques. A high-resolution digital phantom was created by shape-based interpolation of the digital Hoffman brain phantom. Three different sets of 20 movements were applied to the phantom. For each frame of the motion, sinograms with attenuation and three levels of noise were simulated and then reconstructed using filtered backprojection. The average of the 20 frames was considered the motion blurred image, which was restored with the deconvolution algorithm. After correction, contrast increased from a mean of 2.0, 1.8 and 1.4 in the motion blurred images, for the three increasing amounts of movement, to a mean of 2.5, 2.4 and 2.2. Mean error was reduced by an average of 55% with motion correction. In conclusion, deconvolution can be used for correction of motion blur when subject motion is known.

  6. Motion correction of PET brain images through deconvolution: I. Theoretical development and analysis in software simulations

    Energy Technology Data Exchange (ETDEWEB)

    Faber, T L; Raghunath, N; Tudorascu, D; Votaw, J R [Department of Radiology, Emory University Hospital, 1364 Clifton Road, N.E. Atlanta, GA 30322 (United States)], E-mail: tfaber@emory.edu

    2009-02-07

    Image quality is significantly degraded even by small amounts of patient motion in very high-resolution PET scanners. Existing correction methods that use known patient motion obtained from tracking devices either require multi-frame acquisitions, detailed knowledge of the scanner, or specialized reconstruction algorithms. A deconvolution algorithm has been developed that alleviates these drawbacks by using the reconstructed image to estimate the original non-blurred image using maximum likelihood estimation maximization (MLEM) techniques. A high-resolution digital phantom was created by shape-based interpolation of the digital Hoffman brain phantom. Three different sets of 20 movements were applied to the phantom. For each frame of the motion, sinograms with attenuation and three levels of noise were simulated and then reconstructed using filtered backprojection. The average of the 20 frames was considered the motion blurred image, which was restored with the deconvolution algorithm. After correction, contrast increased from a mean of 2.0, 1.8 and 1.4 in the motion blurred images, for the three increasing amounts of movement, to a mean of 2.5, 2.4 and 2.2. Mean error was reduced by an average of 55% with motion correction. In conclusion, deconvolution can be used for correction of motion blur when subject motion is known.

  7. Symmetric geometric transfer matrix partial volume correction for PET imaging: principle, validation and robustness

    Science.gov (United States)

    Sattarivand, Mike; Kusano, Maggie; Poon, Ian; Caldwell, Curtis

    2012-11-01

    Limited spatial resolution of positron emission tomography (PET) often requires partial volume correction (PVC) to improve the accuracy of quantitative PET studies. Conventional region-based PVC methods use co-registered high resolution anatomical images (e.g. computed tomography (CT) or magnetic resonance images) to identify regions of interest. Spill-over between regions is accounted for by calculating regional spread functions (RSFs) in a geometric transfer matrix (GTM) framework. This paper describes a new analytically derived symmetric GTM (sGTM) method that relies on spill-over between RSFs rather than between regions. It is shown that the sGTM is mathematically equivalent to Labbe's method; however it is a region-based method rather than a voxel-based method and it avoids handling large matrices. The sGTM method was validated using two three-dimensional (3D) digital phantoms and one physical phantom. A 3D digital sphere phantom with sphere diameters ranging from 5 to 30 mm and a sphere-to-background uptake ratio of 3-to-1 was used. A 3D digital brain phantom was used with four different anatomical regions and a background region with different activities assigned to each region. A physical sphere phantom with the same geometry and uptake as the digital sphere phantom was manufactured and PET-CT images were acquired. Using these three phantoms, the performance of the sGTM method was assessed against that of the GTM method in terms of accuracy, precision, noise propagation and robustness. The robustness was assessed by applying mis-registration errors and errors in estimates of PET point spread function (PSF). In all three phantoms, the results showed that the sGTM method has accuracy similar to that of the GTM method and within 5%. However, the sGTM method showed better precision and noise propagation than the GTM method, especially for spheres smaller than 13 mm. Moreover, the sGTM method was more robust than the GTM method when mis-registration errors or

  8. Symmetric geometric transfer matrix partial volume correction for PET imaging: principle, validation and robustness

    International Nuclear Information System (INIS)

    Sattarivand, Mike; Caldwell, Curtis; Kusano, Maggie; Poon, Ian

    2012-01-01

    Limited spatial resolution of positron emission tomography (PET) often requires partial volume correction (PVC) to improve the accuracy of quantitative PET studies. Conventional region-based PVC methods use co-registered high resolution anatomical images (e.g. computed tomography (CT) or magnetic resonance images) to identify regions of interest. Spill-over between regions is accounted for by calculating regional spread functions (RSFs) in a geometric transfer matrix (GTM) framework. This paper describes a new analytically derived symmetric GTM (sGTM) method that relies on spill-over between RSFs rather than between regions. It is shown that the sGTM is mathematically equivalent to Labbe's method; however it is a region-based method rather than a voxel-based method and it avoids handling large matrices. The sGTM method was validated using two three-dimensional (3D) digital phantoms and one physical phantom. A 3D digital sphere phantom with sphere diameters ranging from 5 to 30 mm and a sphere-to-background uptake ratio of 3-to-1 was used. A 3D digital brain phantom was used with four different anatomical regions and a background region with different activities assigned to each region. A physical sphere phantom with the same geometry and uptake as the digital sphere phantom was manufactured and PET-CT images were acquired. Using these three phantoms, the performance of the sGTM method was assessed against that of the GTM method in terms of accuracy, precision, noise propagation and robustness. The robustness was assessed by applying mis-registration errors and errors in estimates of PET point spread function (PSF). In all three phantoms, the results showed that the sGTM method has accuracy similar to that of the GTM method and within 5%. However, the sGTM method showed better precision and noise propagation than the GTM method, especially for spheres smaller than 13 mm. Moreover, the sGTM method was more robust than the GTM method when mis-registration errors or

  9. Image artifacts from MR-based attenuation correction in clinical, whole-body PET/MRI

    DEFF Research Database (Denmark)

    Keller, Sune H; Holm, Søren; Hansen, Adam E

    2013-01-01

    Integrated whole-body PET/MRI tomographs have become available. PET/MR imaging has the potential to supplement, or even replace combined PET/CT imaging in selected clinical indications. However, this is true only if methodological pitfalls and image artifacts arising from novel MR-based attenuation...

  10. Imaging with PET system

    International Nuclear Information System (INIS)

    Das, B.K.; Noreen Norfaraheen Lee Abdullah

    2012-01-01

    PET deals with biochemistry and metabolic changes that occur at molecular level. Hence, PET differs fundamentally from other imaging modalities. CT imaging is based on tissue density, whereas MRI conveys anatomic information based on proton density and proton relaxation dynamics. CT and MRI are useful in clinical diagnosis only when disease process has caused significant anatomic alterations. However, in most disease conditions chemical changes precede anatomic changes, that can be detected by PET technology. Thus, PET can provide earliest and unique information about ongoing disease process long before anatomic or structural changes take place. There is no other modality available at present that can replace PET technology. Although PET produces cross-sectional images like that obtained in MRI or CT, they represent circulation, function and metabolism, and not anatomic structure. PET is extremely sensitive measuring quantitatively concentration of tracers in nano to pico-molar range. Thus, PET enables merger of biochemistry and biology in medicine giving birth to molecular medicine that focuses on identifying the molecular errors of disease leading to developing molecular corrections including gene therapy. Molecular imaging with PET has been playing a role in examining the biological nature of a disease condition and its characterization to guide selection and evaluation of treatment. (author)

  11. Conoco serves an ACE

    Energy Technology Data Exchange (ETDEWEB)

    Cottrill, A.; Jackson, G. [Arup Energy (United Kingdom)

    2001-06-01

    The Hang Tuah gas platform recently installed in Conoco's West Natuna field off Indonesia is the first example in the world of a low-cost, relocatable platform based on the ACE concept developed by Arup Energy in the UK. It is expected to operate at two other locations in the West Natuna block during its 25-year lifetime. The ACE platform, which can operate at depths up to 100 m, has four main components: the deck in the form of a barge, strand jacks to lower the four lattice legs on a rectangular steel gravity base, and a jacking system. The background to the decision to opt for the ACE concept, its advantages, the delivery contract, the platform's flexibility, and its fabrication and installation are described. The weights of the various components and the levels to which loads can be raised are summarised in a table. The areas where cost savings are made with this design are explained in a side box.

  12. Evaluation of whether the ACE gene I/D polymorphism constitutes a risk factor for chronic obstructive pulmonary disease in the Turkish population.

    Science.gov (United States)

    Ayada, C; Toru, U; Genç, O; Yerlikaya, A; Sahin, S; Turgut, S; Turgut, G

    2014-12-12

    Chronic obstructive pulmonary disease (COPD) is characterized by progressive airflow obstruction that occurs as a result of the normal inflammatory process to protect against harmful irritants and chemicals. Another physiological regulatory process, the renin angiotensin system (RAS), plays an important role in the pathology of many diseases. Angiotensin converting enzyme (ACE) is a key enzyme of RAS. We investigated the frequency of the ACE gene I/D polymorphism in patients with COPD in Turkey. This study was performed on 47 unrelated patients with COPD and 64 healthy subjects. DNA samples were isolated from peripheral blood, and ACE DNA was amplified by polymerase chain reaction. The frequencies of ACE genotypes were 27.7, 55.3, and 17% for DD, ID, and II in the COPD group, respectively, and 43.8, 43.8, and 12.4% in the control group. There was no statistically significant difference between groups (X(2) = 3.078; df = 2; P = 0.220). The distributions of ACE gene D alleles were 38.2% (N = 52) in the COPD group and 61.8% (N = 84) in the control group; and those of I alleles were 48.8% (N = 42) in the COPD group and 51.2% (N = 44) in the control group. There was no statistically significant difference between groups for allele frequency (X(2) = 2.419; df = 2; P = 0.120). We believe these results can be useful for large-scale population genetic research considering the frequency of the ACE gene variation in COPD patients in the Turkish population.

  13. Estimation of the relationship between the polymorphisms of selected genes: ACE, AGTR1, TGFβ1 and GNB3 with the occurrence of primary vesicoureteral reflux.

    Science.gov (United States)

    Życzkowski, Marcin; Żywiec, Joanna; Nowakowski, Krzysztof; Paradysz, Andrzej; Grzeszczak, Władyslaw; Gumprecht, Janusz

    2017-03-01

    Etiopathogenesis of VUR is composite and not fully understood. Many data indicate the importance of genetic predisposition. The aim of this study was to establish the relationship of selected polymorphisms: 14094 polymorphism of the ACE, polymorphism rs1800469 of TGFβ-1, rs5443 gene polymorphism of the GNB3 and receptor gene polymorphism rs5186 type 1 AGTR1 with the occurrence of the primary vesicoureteral reflux. The study included 190 children: 90 with the primary VUR confirmed with the voiding cystourethrogram and excluded secondary VUR and a control group of 100 children without a history of the diseases of the genitourinary tract. The study was planned in the scheme: "tested case versus control." Genomic DNA was isolated from the leukocytes of peripheral blood samples. The results were statistically analyzed in the Statistica 10 using χ 2 test and analysis of the variance Anova. Any of the four studied polymorphisms showed no difference in the distribution of genotypes between patients with primary vesicoureteral reflux and the control group. In patients with VUR and TT genotype polymorphism rs5443 GNB3 gene, the glomerular filtration rate was significantly higher than in patients with genotype CC or CT. (1) No relationship was found between the studied polymorphisms (14094 ACE gene, rs1800469 gene TGFβ1, GNB3 gene rs5443, rs5186 AGTR1 gene) and the occurrence of primary vesicoureteral reflux. (2) TT genotype polymorphism rs5443 GNB3 gene may be a protective factor for the improved renal function in patients with primary vesicoureteral reflux in patients with genotype CC or CT.

  14. Validation of ozone measurements from the Atmospheric Chemistry Experiment (ACE

    Directory of Open Access Journals (Sweden)

    E. Dupuy

    2009-01-01

    Full Text Available This paper presents extensive {bias determination} analyses of ozone observations from the Atmospheric Chemistry Experiment (ACE satellite instruments: the ACE Fourier Transform Spectrometer (ACE-FTS and the Measurement of Aerosol Extinction in the Stratosphere and Troposphere Retrieved by Occultation (ACE-MAESTRO instrument. Here we compare the latest ozone data products from ACE-FTS and ACE-MAESTRO with coincident observations from nearly 20 satellite-borne, airborne, balloon-borne and ground-based instruments, by analysing volume mixing ratio profiles and partial column densities. The ACE-FTS version 2.2 Ozone Update product reports more ozone than most correlative measurements from the upper troposphere to the lower mesosphere. At altitude levels from 16 to 44 km, the average values of the mean relative differences are nearly all within +1 to +8%. At higher altitudes (45–60 km, the ACE-FTS ozone amounts are significantly larger than those of the comparison instruments, with mean relative differences of up to +40% (about +20% on average. For the ACE-MAESTRO version 1.2 ozone data product, mean relative differences are within ±10% (average values within ±6% between 18 and 40 km for both the sunrise and sunset measurements. At higher altitudes (~35–55 km, systematic biases of opposite sign are found between the ACE-MAESTRO sunrise and sunset observations. While ozone amounts derived from the ACE-MAESTRO sunrise occultation data are often smaller than the coincident observations (with mean relative differences down to −10%, the sunset occultation profiles for ACE-MAESTRO show results that are qualitatively similar to ACE-FTS, indicating a large positive bias (mean relative differences within +10 to +30% in the 45–55 km altitude range. In contrast, there is no significant systematic difference in bias found for the ACE-FTS sunrise and sunset measurements.

  15. Monte Carlo simulation and scatter correction of the GE Advance PET scanner with SimSET and Geant4

    International Nuclear Information System (INIS)

    Barret, Olivier; Carpenter, T Adrian; Clark, John C; Ansorge, Richard E; Fryer, Tim D

    2005-01-01

    For Monte Carlo simulations to be used as an alternative solution to perform scatter correction, accurate modelling of the scanner as well as speed is paramount. General-purpose Monte Carlo packages (Geant4, EGS, MCNP) allow a detailed description of the scanner but are not efficient at simulating voxel-based geometries (patient images). On the other hand, dedicated codes (SimSET, PETSIM) will perform well for voxel-based objects but will be poor in their capacity of simulating complex geometries such as a PET scanner. The approach adopted in this work was to couple a dedicated code (SimSET) with a general-purpose package (Geant4) to have the efficiency of the former and the capabilities of the latter. The combined SimSET+Geant4 code (SimG4) was assessed on the GE Advance PET scanner and compared to the use of SimSET only. A better description of the resolution and sensitivity of the scanner and of the scatter fraction was obtained with SimG4. The accuracy of scatter correction performed with SimG4 and SimSET was also assessed from data acquired with the 20 cm NEMA phantom. SimG4 was found to outperform SimSET and to give slightly better results than the GE scatter correction methods installed on the Advance scanner (curve fitting and scatter modelling for the 300-650 keV and 375-650 keV energy windows, respectively). In the presence of a hot source close to the edge of the field of view (as found in oxygen scans), the GE curve-fitting method was found to fail whereas SimG4 maintained its performance

  16. Association of the insertion allele of the common ACE gene polymorphism with type 2 diabetes mellitus among Kuwaiti cardiovascular disease patients.

    Science.gov (United States)

    Al-Serri, Ahmad; Ismael, Fatma G; Al-Bustan, Suzanne A; Al-Rashdan, Ibrahim

    2015-12-01

    The D allele of the common angiotensin-converting enzyme (ACE) I/D gene polymorphism (rs4646994) predisposes to type 2 diabetes mellitus (T2DM) and cardiovascular disease (CVD). However, results on which allele predisposes to disease susceptibility remain controversial in Asian populations. This study was performed to evaluate the association of the common ACE I/D gene polymorphism with both T2DM and CVD susceptibility in an Arab population. We genotyped the ACE I/D polymorphisms by direct allele-specific PCR in 183 healthy controls and 400 CVD patients with diabetes (n=204) and without (n=196). Statistical analysis comparing between the different groups were conducted using R statistic package "SNPassoc". Two genetic models were used: the additive and co-dominant models. The I allele was found to be associated with T2DM (OR=1.84, p=0.00009) after adjusting for age, sex and body mass index. However, there was no association with CVD susceptibility (p>0.05). The ACE I allele is found to be associated with T2DM; however, no association was observed with CVD. The inconsistency between studies is suggested to be attributed to genetic diversity due to the existence of sub-populations found in Asian populations. © The Author(s) 2015.

  17. Validation of a simultaneous PET/MR system model for PET simulation using GATE

    International Nuclear Information System (INIS)

    Monnier, Florian; Fayad, Hadi; Bert, Julien; Schmidt, Holger; Visvikis, Dimitris

    2015-01-01

    Simultaneous PET/MR acquisition shows promise in a range of applications. Simulation using GATE is an essential tool that allows obtaining the ground truth for such acquisitions and therefore helping in the development and the validation of innovative processing methods such as PET image reconstruction, attenuation correction and motion correction. The purpose of this work is to validate the GATE simulation of the Siemens Biograph mMR PET/MR system. A model of the Siemens Biograph mMR was developed. This model includes the geometry and spatial positioning of the crystals inside the scanner and the characteristics of the detection process. The accuracy of the model was tested by comparing, on a real physical phantom study, GATE simulated results to reconstructed PET images using measured results obtained from a Siemens Biograph mMR system. The same parameters such as the acquisition time and phantom position inside the scanner were fixed for our simulations. List-mode outputs were recovered in both cases and reconstructed using the OPL-EM algorithm. Several parameters were used to compare the two reconstructed images such as profile comparison, signal-to-noise ratio and activity contrast analysis. Finally patient acquired MR images were segmented and used for the simulation of corresponding PET images. The simulated and acquired sets of reconstructed phantom images showed close emission values in regions of interest with relative differences lower than 5%. The scatter fraction was within a <3% agreement. Close matching of profiles and contrast indices were obtained between simulated and corresponding acquired PET images. Our results indicate that the GATE developed Biograph mMR model is accurate in comparison to the real scanner performance and can be used for evaluating innovative processing methods for applications in clinical PET/MR protocols.

  18. List-mode-based reconstruction for respiratory motion correction in PET using non-rigid body transformations

    International Nuclear Information System (INIS)

    Lamare, F; Carbayo, M J Ledesma; Cresson, T; Kontaxakis, G; Santos, A; Rest, C Cheze Le; Reader, A J; Visvikis, D

    2007-01-01

    Respiratory motion in emission tomography leads to reduced image quality. Developed correction methodology has been concentrating on the use of respiratory synchronized acquisitions leading to gated frames. Such frames, however, are of low signal-to-noise ratio as a result of containing reduced statistics. In this work, we describe the implementation of an elastic transformation within a list-mode-based reconstruction for the correction of respiratory motion over the thorax, allowing the use of all data available throughout a respiratory motion average acquisition. The developed algorithm was evaluated using datasets of the NCAT phantom generated at different points throughout the respiratory cycle. List-mode-data-based PET-simulated frames were subsequently produced by combining the NCAT datasets with Monte Carlo simulation. A non-rigid registration algorithm based on B-spline basis functions was employed to derive transformation parameters accounting for the respiratory motion using the NCAT dynamic CT images. The displacement matrices derived were subsequently applied during the image reconstruction of the original emission list mode data. Two different implementations for the incorporation of the elastic transformations within the one-pass list mode EM (OPL-EM) algorithm were developed and evaluated. The corrected images were compared with those produced using an affine transformation of list mode data prior to reconstruction, as well as with uncorrected respiratory motion average images. Results demonstrate that although both correction techniques considered lead to significant improvements in accounting for respiratory motion artefacts in the lung fields, the elastic-transformation-based correction leads to a more uniform improvement across the lungs for different lesion sizes and locations

  19. Additional value of PET-CT in the staging of lung cancer: comparison with CT alone, PET alone and visual correlation of PET and CT

    International Nuclear Information System (INIS)

    Wever, W. de; Marchal, G.; Bogaert, J.; Verschakelen, J.A.; Ceyssens, S.; Mortelmans, L.; Stroobants, S.

    2007-01-01

    Integrated positron emission tomography (PET) and computed tomography (CT) is a new imaging modality offering anatomic and metabolic information. The purpose was to evaluate retrospectively the accuracy of integrated PET-CT in the staging of a suggestive lung lesion, comparing this with the accuracy of CT alone, PET alone and visually correlated PET-CT. Fifty patients undergoing integrated PET-CT for staging of a suggestive lung lesion were studied. Their tumor, node, metastasis (TNM) statuses were determined with CT, PET, visually correlated PET-CT and integrated PET-CT. These TNM stages were compared with the surgical TNM status. Integrated PET-CT was the most accurate imaging technique in the assessment of the TNM status. Integrated PET-CT predicted correctly the T status, N status, M status and TNM status in, respectively, 86%, 80%, 98%, 70% versus 68%, 66%,88%, 46% with CT, 46%, 70%, 96%, 30% with PET and 72%, 68%, 96%, 54% with visually correlated PET-CT. T status and N status were overstaged, respectively, in 8% and 16% with integrated PET-CT, in 20% and 28% with CT, in 16% and 20% with PET, in 12% and 20% with visually correlated PET-CT and understaged in 6% and 4% with integrated PET-CT, versus 12% and 6% with CT, 38% and 10% with PET and 12% with visually correlated PET-CT. Integrated PET-CT improves the staging of lung cancer through a better anatomic localization and characterization of lesions and is superior to CT alone and PET alone. If this technique is not available, visual correlation of PET and CT can be a valuable alternative. (orig.)

  20. Circulating ACE2 activity correlates with cardiovascular disease development

    Directory of Open Access Journals (Sweden)

    Katalin Úri

    2016-12-01

    Full Text Available It was shown recently that angiotensin-converting enzyme activity is limited by endogenous inhibition in vivo, highlighting the importance of angiotensin II (ACE2 elimination. The potential contribution of the ACE2 to cardiovascular disease progression was addressed. Serum ACE2 activities were measured in different clinical states (healthy, n=45; hypertensive, n=239; heart failure (HF with reduced ejection fraction (HFrEF n=141 and HF with preserved ejection fraction (HFpEF n=47. ACE2 activity was significantly higher in hypertensive patients (24.8±0.8 U/ml than that in healthy volunteers (16.2±0.8 U/ml, p=0.01. ACE2 activity further increased in HFrEF patients (43.9±2.1 U/ml, p=0.001 but not in HFpEF patients (24.6±1.9 U/ml when compared with hypertensive patients. Serum ACE2 activity negatively correlated with left ventricular systolic function in HFrEF, but not in hypertensive, HFpEF or healthy populations. Serum ACE2 activity had a fair diagnostic value to differentiate HFpEF from HFrEF patients in this study. Serum ACE2 activity correlates with cardiovascular disease development: it increases when hypertension develops and further increases when the cardiovascular disease further progresses to systolic dysfunction, suggesting that ACE2 metabolism plays a role in these processes. In contrast, serum ACE2 activity does not change when hypertension progresses to HFpEF, suggesting a different pathomechanism for HFpEF, and proposing a biomarker-based identification of these HF forms.

  1. Multiple ace genes encoding acetylcholinesterases of Caenorhabditis elegans have distinct tissue expression.

    Science.gov (United States)

    Combes, Didier; Fedon, Yann; Toutant, Jean-Pierre; Arpagaus, Martine

    2003-08-01

    ace-1 and ace-2 genes encoding acetylcholinesterase in the nematode Caenorhabditis elegans present 35% identity in coding sequences but no homology in noncoding regions (introns, 5'- and 3'-untranslated regions). A 5'-region of ace-2 was defined by rescue of ace-1;ace-2 mutants. When green fluorescent protein (GFP) expression was driven by this regulatory region, the resulting pattern was distinct from that of ace-1. This latter gene is expressed in all body-wall and vulval muscle cells (Culetto et al., 1999), whereas ace-2 is expressed almost exclusively in neurons. ace-3 and ace-4 genes are located in close proximity on chromosome II (Combes et al., 2000). These two genes were first transcribed in vivo as a bicistronic messenger and thus constitute an ace-3;ace-4 operon. However, there was a very low level of monocistronic mRNA of ace-4 (the upstream gene) in vivo, and no ACE-4 enzymatic activity was ever detected. GFP expression driven by a 5' upstream region of the ace-3;ace-4 operon was detected in several muscle cells of the pharynx (pm3, pm4, pm5 and pm7) and in the two canal associated neurons (CAN cells). A dorsal row of body-wall muscle cells was intensively labelled in larval stages but no longer detected in adults. The distinct tissue-specific expression of ace-1, ace-2 and ace-3 (coexpressed only in pm5 cells) indicates that ace genes are not redundant.

  2. 4D PET iterative deconvolution with spatiotemporal regularization for quantitative dynamic PET imaging.

    Science.gov (United States)

    Reilhac, Anthonin; Charil, Arnaud; Wimberley, Catriona; Angelis, Georgios; Hamze, Hasar; Callaghan, Paul; Garcia, Marie-Paule; Boisson, Frederic; Ryder, Will; Meikle, Steven R; Gregoire, Marie-Claude

    2015-09-01

    Quantitative measurements in dynamic PET imaging are usually limited by the poor counting statistics particularly in short dynamic frames and by the low spatial resolution of the detection system, resulting in partial volume effects (PVEs). In this work, we present a fast and easy to implement method for the restoration of dynamic PET images that have suffered from both PVE and noise degradation. It is based on a weighted least squares iterative deconvolution approach of the dynamic PET image with spatial and temporal regularization. Using simulated dynamic [(11)C] Raclopride PET data with controlled biological variations in the striata between scans, we showed that the restoration method provides images which exhibit less noise and better contrast between emitting structures than the original images. In addition, the method is able to recover the true time activity curve in the striata region with an error below 3% while it was underestimated by more than 20% without correction. As a result, the method improves the accuracy and reduces the variability of the kinetic parameter estimates calculated from the corrected images. More importantly it increases the accuracy (from less than 66% to more than 95%) of measured biological variations as well as their statistical detectivity. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  3. A simple algorithm for subregional striatal uptake analysis with partial volume correction in dopaminergic PET imaging

    International Nuclear Information System (INIS)

    Lue Kunhan; Lin Hsinhon; Chuang Kehshih; Kao Chihhao, K.; Hsieh Hungjen; Liu Shuhsin

    2014-01-01

    In positron emission tomography (PET) of the dopaminergic system, quantitative measurements of nigrostriatal dopamine function are useful for differential diagnosis. A subregional analysis of striatal uptake enables the diagnostic performance to be more powerful. However, the partial volume effect (PVE) induces an underestimation of the true radioactivity concentration in small structures. This work proposes a simple algorithm for subregional analysis of striatal uptake with partial volume correction (PVC) in dopaminergic PET imaging. The PVC algorithm analyzes the separate striatal subregions and takes into account the PVE based on the recovery coefficient (RC). The RC is defined as the ratio of the PVE-uncorrected to PVE-corrected radioactivity concentration, and is derived from a combination of the traditional volume of interest (VOI) analysis and the large VOI technique. The clinical studies, comprising 11 patients with Parkinson's disease (PD) and 6 healthy subjects, were used to assess the impact of PVC on the quantitative measurements. Simulations on a numerical phantom that mimicked realistic healthy and neurodegenerative situations were used to evaluate the performance of the proposed PVC algorithm. In both the clinical and the simulation studies, the striatal-to-occipital ratio (SOR) values for the entire striatum and its subregions were calculated with and without PVC. In the clinical studies, the SOR values in each structure (caudate, anterior putamen, posterior putamen, putamen, and striatum) were significantly higher by using PVC in contrast to those without. Among the PD patients, the SOR values in each structure and quantitative disease severity ratings were shown to be significantly related only when PVC was used. For the simulation studies, the average absolute percentage error of the SOR estimates before and after PVC were 22.74% and 1.54% in the healthy situation, respectively; those in the neurodegenerative situation were 20.69% and 2

  4. Efficacy of lycopene on modulation of renal antioxidant enzymes, ACE and ACE gene expression in hyperlipidaemic rats.

    Science.gov (United States)

    Khan, Nazish Iqbal; Noori, Shafaq; Mahboob, Tabassum

    2016-07-01

    We aimed to evaluate the efficacy of lycopene on renal tissue antioxidant enzymes and angiotensin converting enzyme (ACE) gene expression and serum activity in diet-induced hyperlipidaemia. Thirty-two female Wistar albino rats (200-250 g weight), 5-6 months of age, were randomly selected and divided into four groups. Group I received normal diet; group II received 24 g high fat diet/100 g of daily diet; group III received 24 g high fat diet/100 g daily diet and 200 ml of lycopene extract (twice a week) for 8 weeks; and group IV received 200 ml oral lycopene extract twice a week for 8 weeks. A marked increase was observed in plasma urea and creatinine levels, serum C-reactive protein, kidney weight, tissue renal malonyldialdehyde level, ACE gene expression and serum level, while a decrease catalase level among hyperlipidaemic rats was observed. Histologically, interstitial inflammation and proliferation was seen. Lycopene supplementation significantly decreased plasma urea and creatinine, serum ACE, renal tissue malonyldialdehyde level and C-reactive protein level, while it increased tissue antioxidant enzymes level and total protein. Tissue inflammation and proliferation was improved. This finding suggests that supplementation of lycopene is effective for renal antioxidant enzymes, ACE gene expression and ACE serum level in hyperlipidaemic rats. © The Author(s) 2016.

  5. Polymorphism of angiotensin-converting enzyme gene in sarcoidosis.

    Science.gov (United States)

    Arbustini, E; Grasso, M; Leo, G; Tinelli, C; Fasani, R; Diegoli, M; Banchieri, N; Cipriani, A; Gorrini, M; Semenzato, G; Luisetti, M

    1996-02-01

    Sarcoidosis is the disease in which increased levels of serum Angiotensin-converting enzyme (sACE) are most often detected. It has recently been shown that the deletion (D) or the insertion (I) of a 250bp-DNA fragment in the ACE gene accounts for three main ACE genotypes (i.e., II, ID, and DD) and for 47% of total phenotypic variance in sACE level. The aim of our work was to investigate whether or not patients with sarcoidosis have an increased incidence of those ACE genotypes coding for highest sACE levels and to investigate whether or not sACE level in sarcoidosis is related to ACE genotypes. We studied 61 unrelated patients with sarcoidosis (test group) and 80 unrelated healthy control subjects (control group). The ACE I and D alleles were detected with polymerase chain reaction on genomic DNA. In the control group we found an ACE genotype distribution that agreed with the Hardy-Weinberg proportion. The ACE genotype distribution was not significantly different in the test group. There was no correlation between ACE genotype and roentgenologic stage of sarcoidosis. Plotting the sACE level in the control group against ACE genotype, we found a trend of increasing mean sACE value according to the order II sACE values plotted against roentgenologic stage, according to the order Stage I sACE values in sarcoidosis according to both ACE genotype and roentgenologic stage would suggest that both mechanisms play a role in determining sACE level.

  6. Association of ACE gene A2350G and I/D polymorphisms with essential hypertension in the northernmost province of China.

    Science.gov (United States)

    Sun, Feifei; He, Ning; Zhang, Keyong; Wu, Nan; Zhao, Jingbo; Qiu, Changchun

    2018-01-01

    Angiotensin converting enzyme (ACE) gene, as a strong candidate gene for essential hypertension(EH), has been extensively studied. In this study, we carried out a population-based case-control study to explore whether ACE gene I/D and A2350G polymorphisms could consider to be risk factors for EH. A total of 2040 subjeces were recruited from Chinese Han in this study, out of which 1010 were cases and 1030 were normotensive individuals. ACE gene A2350G and I/D polymorphisms were amplified by polymerase chain reaction (PCR) and A2350G polymorphism was detected after restriction enzyme digestion with BstuI. Besides, we choosed 10% samples randomly sequencing to verify the accuracy of results. Genotype and allele frequencies distribution of I/D and A2350G in EH and control groups were significantly different. After grouped by sex or age, there were still statistical significances for two polymorphisms. In dominant and recessive model of A2350G, we found significant differences between two groups, respectively. For ACE I/D polymorphism, we observed that the existence of dramatical difference in dominant model between two groups, while in recessive model, marginally significant difference was found. Among the four haplotypes composed by ACE gene A2350G and I/D, haplotype G-D reached the statistical significance in two groups, and exhibited to be a risk factor for the development of EH, whose P ACE gene A2350G and I/D polymorphisms were associated with increasing the risk of suffering from EH in the northernmost province of China individuals, with D allele and G allele individuals had a higher risk of EH(OR = 1.443, 95%CI = 1.273-1.636 and OR = 1.481, 95%CI = 1.303-1.684).

  7. Impact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer

    Directory of Open Access Journals (Sweden)

    Michael Masoomi

    2013-10-01

    Full Text Available AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT. Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The motion correction technique adopted in this study was an image-based motion correction approach using, an in-house developed voxel-intensity-based and a multi-resolution multi-optimisation (MRMO algorithm. All the generated frames were co-registered to a reference frame using a time efficient scheme. The NCAT phantom was used to generate CT attenuation maps and activity distribution volumes for the lung regions. Quantitative assessment including Region of Interest (ROI, image fidelity and image correlation techniques, as well as semi-quantitative line profile analysis and qualitatively overlaying non-motion and motion corrected image frames were performed. Results: the largest transformation was observed in the Z-direction. The greatest translation was for the frame 3, end inspiration, and the smallest for the frame 5 which was closet frame to the reference frame at 67% expiration. Visual assessment of the lesion sizes, 20-60mm at 3 different locations, apex, mid and base of lung showed noticeable improvement for all the foci and their locations. The maximum improvements for the image fidelity were from 0.395 to 0.930 within the lesion volume of interest. The greatest improvement in activity concentration underestimation, post motion correction, was 7% below the true activity for the 20 mm lesion. The discrepancies in activity underestimation were reduced with increasing the lesion sizes. Overlay activity distribution on the attenuation map showed improved localization of the PET metabolic information to the anatomical CT images. Conclusion: The respiratory

  8. Regulation of the aceI multidrug efflux pump gene in Acinetobacter baumannii.

    Science.gov (United States)

    Liu, Qi; Hassan, Karl A; Ashwood, Heather E; Gamage, Hasinika K A H; Li, Liping; Mabbutt, Bridget C; Paulsen, Ian T

    2018-06-01

    To investigate the function of AceR, a putative transcriptional regulator of the chlorhexidine efflux pump gene aceI in Acinetobacter baumannii. Chlorhexidine susceptibility and chlorhexidine induction of aceI gene expression were determined by MIC and quantitative real-time PCR, respectively, in A. baumannii WT and ΔaceR mutant strains. Recombinant AceR was prepared as both a full-length protein and as a truncated protein, AceR (86-299), i.e. AceRt, which has the DNA-binding domain deleted. The binding interaction of the purified AceR protein and its putative operator region was investigated by electrophoretic mobility shift assays and DNase I footprinting assays. The binding of AceRt with its putative ligand chlorhexidine was examined using surface plasmon resonance and tryptophan fluorescence quenching assays. MIC determination assays indicated that the ΔaceI and ΔaceR mutant strains both showed lower resistance to chlorhexidine than the parental strain. Chlorhexidine-induced expression of aceI was abolished in a ΔaceR background. Electrophoretic mobility shift assays and DNase I footprinting assays demonstrated chlorhexidine-stimulated binding of AceR with two sites upstream of the putative aceI promoter. Surface plasmon resonance and tryptophan fluorescence quenching assays suggested that the purified ligand-binding domain of the AceR protein was able to bind with chlorhexidine with high affinity. This study provides strong evidence that AceR is an activator of aceI gene expression when challenged with chlorhexidine. This study is the first characterization, to our knowledge, of a regulator controlling expression of a PACE family multidrug efflux pump.

  9. 78 FR 69434 - Post-Summary Corrections to Entry Summaries Filed in ACE Pursuant to the ESAR IV Test...

    Science.gov (United States)

    2013-11-19

    ... the testing of National Customs Automation Program (NCAP) components. A chronological listing of... conduct a NCAP test concerning new ACE ESAR IV capabilities (``ESAR IV test''). The ESAR IV test permitted... IV) Capabilities: 76 FR 37136 (June 24, 2011). NCAP Test Concerning the Document Imaging System: 77...

  10. ANGIOTENSIN-CONVERTING ENZYME GENOTYPE AFFECTS SKELETAL MUSCLE STRENGTH IN ELITE ATHLETES

    Directory of Open Access Journals (Sweden)

    Aldo Matos Costa

    2009-09-01

    Full Text Available Previous studies have associated angiotensin-converting enzyme (ACE D allele with variability in the skeletal muscle baseline strength, though conclusions have been inconsistent across investigations. The purpose of this study was to examine the possible association between ACE genotype and skeletal muscle baseline strength in elite male and female athletes involved in different event expertise. A group of 58 elite athletes, designated as Olympic candidates, were studied: 35 swimmers (19 males and 16 females, 18.8 ± 3.2 years and 23 triathletes (15 males and 8 females, 18.7 ± 3.0 years. The athletes were classified as: short (< 200m and middle (400m to 1500m distance athletes, respectively. For each subject the grip strength in both hands was measure using an adjustable mechanical hand dynamometer. The maximum height in both squat jump (SJ and counter movement jump (CMJ were also assessed, using a trigonometric carpet (Ergojump Digitime 1000; Digitest, Jyvaskyla, Finland. DNA extraction was obtained with Chelex 100® and genotype determination by PCR-RFLP methods. Both males and females showed significantly higher right grip strength in D allele carriers compared to II homozygote's. We found that allelic frequency differs significantly by event distance specialization in both genders (p < 0.05. In fact, sprinter D allele carriers showed the superior scores in nearly all strength measurements (p < 0.05, in both genders. Among endurance athletes, the results also demonstrated that female D allele carriers exhibited the higher performance right grip and CMJ scores (p < 0.05. In conclusion, the ACE D allele seems associated with skeletal muscle baseline strength in elite athletes, being easily identified in females

  11. Impact of I/D polymorphism of ACE gene on risk of development and course of chronic obstructive pulmonary disease.

    Science.gov (United States)

    Mlak, Radosław; Homa-Mlak, Iwona; Powrózek, Tomasz; Mackiewicz, Barbara; Michnar, Marek; Krawczyk, Paweł; Dziedzic, Marcin; Rubinsztajn, Renata; Chazan, Ryszarda; Milanowski, Janusz; Małecka-Massalska, Teresa

    2016-04-01

    Chronic obstructive pulmonary disease (COPD) affects more than 10% of the world's population over 40 years of age. The main exogenous risk factor is cigarette smoking; however, only 20% of smokers develop COPD, indicating that some other factors, e.g. genetic, may play an important role in the disease pathogenesis. Recent research indicates that ACE (angiotensin-converting enzyme) may be a susceptibility gene for asthma or COPD. The aim of our study was to determine the influence of I/D (insertion/deletion) polymorphism of the ACE gene (AluYa5, rs4646994) on the risk and course of COPD. We investigated ACE I/D polymorphism in 206 COPD and 165 healthy Caucasian subjects. In the generalized linear model (GLZ) analysis of the influence of selected factors on presence of COPD we found a significant independent effect for male sex (repeatedly increases the risk of COPD, OR = 7.7, p = 0.049), as well as smoking or lower body mass index, but only in combination with older age (OR = 0.96, p = 0.003 and OR = 1.005, p = 0.04 respectively). Interestingly, analysis of factors which may influence the risk of a higher number of exacerbations demonstrated that occurrence of DD genotype, but only in men, is associated with a lower risk (OR = 0.7, p = 0.03) of this complication. We suggest that ACE may not be a susceptibility gene for the origin of COPD but a disease-modifying gene. Since the impact of I/D polymorphism of the ACE gene on COPD risk is moderate or negligible, other molecular changes, that will help predict the development of this disease, should still be sought.

  12. PET/CT: underlying physics, instrumentation, and advances.

    Science.gov (United States)

    Torres Espallardo, I

    Since it was first introduced, the main goal of PET/CT has been to provide both PET and CT images with high clinical quality and to present them to radiologists and specialists in nuclear medicine as a fused, perfectly aligned image. The use of fused PET and CT images quickly became routine in clinical practice, showing the great potential of these hybrid scanners. Thanks to this success, manufacturers have gone beyond considering CT as a mere attenuation corrector for PET, concentrating instead on design high performance PET and CT scanners with more interesting features. Since the first commercial PET/CT scanner became available in 2001, both the PET component and the CT component have improved immensely. In the case of PET, faster scintillation crystals with high stopping power such as LYSO crystals have enabled more sensitive devices to be built, making it possible to reduce the number of undesired coincidence events and to use time of flight (TOF) techniques. All these advances have improved lesion detection, especially in situations with very noisy backgrounds. Iterative reconstruction methods, together with the corrections carried out during the reconstruction and the use of the point-spread function, have improved image quality. In parallel, CT instrumentation has also improved significantly, and 64- and 128-row detectors have been incorporated into the most modern PET/CT scanners. This makes it possible to obtain high quality diagnostic anatomic images in a few seconds that both enable the correction of PET attenuation and provide information for diagnosis. Furthermore, nowadays nearly all PET/CT scanners have a system that modulates the dose of radiation that the patient is exposed to in the CT study in function of the region scanned. This article reviews the underlying physics of PET and CT imaging separately, describes the changes in the instrumentation and standard protocols in a combined PET/CT system, and finally points out the most important

  13. Bayesian PET image reconstruction incorporating anato-functional joint entropy

    International Nuclear Information System (INIS)

    Tang Jing; Rahmim, Arman

    2009-01-01

    We developed a maximum a posterior (MAP) reconstruction method for positron emission tomography (PET) image reconstruction incorporating magnetic resonance (MR) image information, with the joint entropy between the PET and MR image features serving as the regularization constraint. A non-parametric method was used to estimate the joint probability density of the PET and MR images. Using realistically simulated PET and MR human brain phantoms, the quantitative performance of the proposed algorithm was investigated. Incorporation of the anatomic information via this technique, after parameter optimization, was seen to dramatically improve the noise versus bias tradeoff in every region of interest, compared to the result from using conventional MAP reconstruction. In particular, hot lesions in the FDG PET image, which had no anatomical correspondence in the MR image, also had improved contrast versus noise tradeoff. Corrections were made to figures 3, 4 and 6, and to the second paragraph of section 3.1 on 13 November 2009. The corrected electronic version is identical to the print version.

  14. PET/CT staging of T1-stage non-small cell lung cancer

    International Nuclear Information System (INIS)

    Salman, K. A.; Steinmann, C. H.; Von Schulthess, G. K.; Steinert, H. C.; Sukumar, V. P.

    2009-01-01

    Full text:Purpose: To evaluate the value of PET/CT in detecting occult metastases in patients with T 1 -stage non-small cell lung cancer (NSCLC). Method: Patients with proven NSCLC and T 1 -stage ( c m) were retrospectively analyzed. In all patients a whole-body 18 F-FDG PET/CT scan for initial staging was performed. The PET/CT findings were compared with all available clinical information, intra-operative findings and the histopathological results. Results: 95 patients (39 men, 56 women; age range, 19-85 years) were analyzed in our study. PET/CT in 68-95 patients correctly excluded mediastinal and distant metastases. In 17/95 patients (18%) mediastinal lymph-node metastases were proven (N 2 n=15; N 3 n=2). PET/CT correctly detected in 10/17 patients (58.8%) mediastinal nodal disease. The smallest mediastinal lymph-node metastasis detected by PET/CT had a size of 0.7 c m. In 7 patients PET/CT missed N 2 -stage. In three of these patients the SUVmax of the primary was c m. Only in one missed N 2 -stage metastasis was sized > 1.0 c m. The tumor histology (adenocarcinoma, squamous cell carcinoma) and location of the primary (central, periphery) did not influence the missed N 2 -stage by PET/CT. PET/CT diagnosed correctly N 3 -stage in 2 patients. 10/95 patients (10.5%) had distant metastases. PET/CT detected unknown M 1 -stage in 4/10 patients. In one patient a metastasis of the parietal pleura was missed by PET/CT. Conclusion: In our study, 28% patients with T 1 -stage NSCLC showed mediastinal or distant metastases. PET/CT was efficient in the detection of occult metastases. However, the sensitivity of PET/CT in mediastinal staging was only 64%.

  15. Strategies to reduce radiation dose in cardiac PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Tung Hsin; Wu, Nien-Yun [Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei, Taiwan (China); Wang, Shyh-Jen [Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei, Taiwan (China); Department of Nuclear Medicine, Taipei Veterans General Hospital, Taipei, Taiwan (China); Wu, Jay [Institute of Radiological science, Central Taiwan University of Science and Technology, Taichung, Taiwan (China); Mok, Greta S.P. [Department of Electrical and Electronics Engineering, Faculty of Science and Technology, University of Macau, Macau (China); Yang, Ching-Ching, E-mail: g39220003@yahoo.com.tw [Department of Radiological Technology, Tzu Chi College of Technology, 880, Sec.2, Chien-kuo Rd. Hualien 970, Taiwan (China); Huang, Tzung-Chi, E-mail: tzungchi.huang@mail.cmu.edu.tw [Department of Biomedical Imaging and Radiological Science, China Medical University, No.91 Hsueh-Shih Road, Taichung 40402, Taiwan (China)

    2011-08-21

    Background: Our aim was to investigate CT dose reduction strategies on a hybrid PET/CT scanner for cardiac applications. Materials: Image quality and dose estimation of different CT scanning protocols for CT coronary angiography (CTCA), and CT-based attenuation correction for PET imaging were investigated. Fifteen patients underwent CTCA, perfusion PET imaging at rest and under stress, and FDG PET for myocardial viability. These patients were divided into three groups based on the CTCA technique performed: retrospectively gated helical (RGH), ECG tube current modulation (ETCM), and prospective gated axial (PGA) acquisitions. All emission images were corrected for photon attenuation using CT images obtained by default setting and an ultra-low dose CT (ULDCT) scan. Results: Radiation dose in RGH technique was 22.2{+-}4.0 mSv. It was reduced to 10.95{+-}0.82 and 4.13{+-}0.31 mSv using ETCM and PGA techniques, respectively. Radiation dose in CT transmission scan was reduced by 96.5% (from 4.53{+-}0.5 to 0.16{+-}0.01 mSv) when applying ULDCT as compared to the default CT. No significant difference in terms of image quality was found among various protocols. Conclusion: The proposed CT scanning strategies, i.e. ETCM or PGA for CTCA and ULDCT for PET attenuation correction, could reduce radiation dose up to 47% without degrading imaging quality in an integrated cardiac PET/CT coronary artery examination.

  16. The Atmospheric Chemistry Experiment (ACE): Mission Overview

    Science.gov (United States)

    Bernath, P. F.; Boone, C.; Walker, K.; McLeod, S.; Nassar, R.

    2003-12-01

    The ACE mission goals are: (1) to measure and to understand the chemical and dynamical processes that control the distribution of ozone in the upper troposphere and stratosphere, with a particular emphasis on the Arctic region; (2) to explore the relationship between atmospheric chemistry and climate change; (3) to study the effects of biomass burning in the free troposphere; (4) to measure aerosol number density, size distribution and composition in order to reduce the uncertainties in their effects on the global energy balance. ACE will make a comprehensive set of simultaneous measurements of trace gases, thin clouds, aerosols, and temperature by solar occultation from a satellite in low earth orbit. A high inclination (74 degrees) low earth orbit (650 km) gives ACE coverage of tropical, mid-latitudes and polar regions. The solar occultation advantages are high sensitivity and self-calibration. A high-resolution (0.02 cm-1) infrared Fourier Transform Spectrometer (FTS) operating from 2 to 13 microns (750-4100 cm-1) will measure the vertical distribution of trace gases, and the meteorological variables of temperature and pressure. The ACE concept is derived from the now-retired ATMOS FTS instrument, which flew on the Space Shuttle in 1985, 1992, 1993, 1994. Climate-chemistry coupling may lead to the formation of an Arctic ozone hole. ACE will provide high quality data to confront these model predictions and will monitor polar chemistry as chlorine levels decline. The ACE-FTS can measure water vapor and HDO in the tropical tropopause region to study dehydration and strat-trop exchange. The molecular signatures of massive forest fires will evident in the ACE infrared spectra. The CO2 in our spectra can be used to either retrieve atmospheric pressure or (if the instrument pointing knowledge proves to be satisfactory) for an independent retrieval of a CO2 profile for carbon cycle science. Aerosols and clouds will be monitored using the extinction of solar radiation at

  17. ACE blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003567.htm ACE blood test To use the sharing features on this page, ... Alternative Names Serum angiotensin-converting enzyme; SACE Images Blood test References Carty RP, Pincus MR, Sarafraz-Yazdi E. ...

  18. Skull segmentation of UTE MR images by probabilistic neural network for attenuation correction in PET/MR

    Energy Technology Data Exchange (ETDEWEB)

    Santos Ribeiro, A. [Institute of Biophysics and Biomedical Engineering, Lisbon (Portugal); Forschungszentrum Juelich, INM4, Juelich (Germany); Rota Kops, E., E-mail: e.rota.kops@fz-juelich.de [Forschungszentrum Juelich, INM4, Juelich (Germany); Herzog, H. [Forschungszentrum Juelich, INM4, Juelich (Germany); Almeida, P. [Institute of Biophysics and Biomedical Engineering, Lisbon (Portugal)

    2013-02-21

    Aim: Due to space and technical limitations in PET/MR scanners one of the difficulties is the generation of an attenuation correction (AC) map to correct the PET image data. Different methods have been suggested that make use of the images acquired with an ultrashort echo time (UTE) sequence. However, in most of them precise thresholds need to be defined and these may depend on the sequence parameters. In this study an algorithm based on a probabilistic neural network (PNN) is presented requiring little user interaction. Material and methods: An MR UTE sequence delivering two images (UTE1 and UTE2) by using two different echo times (0.07 ms and 2.46 ms, respectively) was acquired. The input features for the PNN algorithm consist of two patches of MR intensities chosen in both the co-registered UTE1 and UTE2 images. At the end, the PNN generates an image classified into four different classes: brain+soft tissue, air, csf, and bone. CT and MR data were acquired in four subjects, whereby the CT data were used for comparison. For each patient co-classification of the different classified classes and the Dice coefficients (D) were calculated between the MR segmented image and the respective CT image. Results: An overall voxel classification accuracy (compared with CT) of 92% was obtained. Also, the resulting D with regard to the skull and calculated for the four subjects show a mean of 0.83 and a standard deviation of 0.07. Discussion: Our results show that a reliable bone segmentation of MRI images as well as the generation of a reliable attenuation map is possible. Conclusion: The developed algorithms possess several advantages over current methods using UTE sequence such as a quick and an easy optimization for different sequence parameters.

  19. Skull segmentation of UTE MR images by probabilistic neural network for attenuation correction in PET/MR

    International Nuclear Information System (INIS)

    Santos Ribeiro, A.; Rota Kops, E.; Herzog, H.; Almeida, P.

    2013-01-01

    Aim: Due to space and technical limitations in PET/MR scanners one of the difficulties is the generation of an attenuation correction (AC) map to correct the PET image data. Different methods have been suggested that make use of the images acquired with an ultrashort echo time (UTE) sequence. However, in most of them precise thresholds need to be defined and these may depend on the sequence parameters. In this study an algorithm based on a probabilistic neural network (PNN) is presented requiring little user interaction. Material and methods: An MR UTE sequence delivering two images (UTE1 and UTE2) by using two different echo times (0.07 ms and 2.46 ms, respectively) was acquired. The input features for the PNN algorithm consist of two patches of MR intensities chosen in both the co-registered UTE1 and UTE2 images. At the end, the PNN generates an image classified into four different classes: brain+soft tissue, air, csf, and bone. CT and MR data were acquired in four subjects, whereby the CT data were used for comparison. For each patient co-classification of the different classified classes and the Dice coefficients (D) were calculated between the MR segmented image and the respective CT image. Results: An overall voxel classification accuracy (compared with CT) of 92% was obtained. Also, the resulting D with regard to the skull and calculated for the four subjects show a mean of 0.83 and a standard deviation of 0.07. Discussion: Our results show that a reliable bone segmentation of MRI images as well as the generation of a reliable attenuation map is possible. Conclusion: The developed algorithms possess several advantages over current methods using UTE sequence such as a quick and an easy optimization for different sequence parameters

  20. Comparison between PET/MR and PET/CT in evaluation of oncological patients%PET/MR与PET/CT的对比研究

    Institute of Scientific and Technical Information of China (English)

    徐白萱; 富丽萍; 关志伟; 尹大一; 刘家金; 杨晖; 张锦明; 陈英茂; 安宁豫

    2014-01-01

    Objective To verify the feasibility of the integrated PET/MR for oncological applications by comparing PET/MR with PET/CT in terms of lesion detection and quantitative measurement.Methods A total of 277 patients (165 males,112 females,average age (52.9± 12.6) years) voluntarily participated in this same-day PET/CT and PET/MR comparative study.The time interval between the two studies was 15-35 min.PET/CT images were acquired and reconstructed following standard protocols.PET/MR covered the body trunk with a sequence combination of transverse T1 weighted imaging (WI) 3D-volumetric interpolated breath-hold,T2WI turbo spin echo with fat saturation,diffusion-weighted imaging,and simultaneous PET acquisition.PET images were reconstructed by vender-provided attenuation correction methods.The results of PET/CT and PET/MR were regarded as positive if any modality (CT,PET or MRI) was positive.SUVmax was obtained by the manually drawn ROI.Detection rates were compared with x2 test and SUVmax from the two modalities was analyzed with Spearman correlation analysis.Results A total of 353 lesions were detected in 220 patients.Compared to PET/CT,PET/MR revealed 30 additional true-positive lesions,while missed 6.The detection rates between PET/CT and PET/MR were significantly different (P<0.05).The lesion-based and patient-based consistency was 89.8% (317/353) and 85.9% (189/220),respectively.There were significant correlations of SUVmax between PET/MR and PET/CT for lesions(rs =0.91,P<0.01) and for normal tissues(rs =0.62-0.76,all P<0.01).Conclusions With reference to PET/CT,integrated PET/MR may provide comparable semi-quantitative measurements of pathological lesions as well as normal tissues.Integrated PET/MR may be more effective to detect lesions in abdomen and pelvis.%目的 通过与PET/CT在病灶检测及定量分析方面的比较,论证PET/MR一体机应用于临床的可行性.方法 2012年5月至2013年2月共300例患者同天间隔15 ~ 35 min行PET/CT和PET

  1. A.L.I.C.E.: an ACE in Digitaland

    Directory of Open Access Journals (Sweden)

    Huma Shah

    2008-07-01

    Full Text Available Artificial linguistic Internet computer entity, A.L.I.C.E. is considered head and shoulders above other artificial conversational entities, an ACE in digitaland. Three times winner of Loebner’s annual instantiation of Turing’s Test for machine intelligence in 2000, 2001 and 2004 judged most human-like machine, A.L.I.C.E. was additionally gold medal champion in 2004, for most knowledgeable programme in Chatterbox Challenge and won bronze medal for most popular ACE. As a modern Eliza, A.L.I.C.E appears as a dark-haired, blue-eyed female avatar, or e-person. The programme’s architecture contains a combinatory scheme including key-word matching, spell checker, grammatical parser, random sentence generator and case-based reasoning or next-neighbour classification. These features allow A.L.I.C.E. to correctly identify the sense of word ‘live’ to produce responses about residential location when asked “where do you live?” and ask question about “subject” being “studied” when presented with “I study a lot”. As a discourse model, discourse features such as information exchange, disclosure of intentions, goals and desires are minimally exhibited in A.L.I.C.E.’s conversations; its verbal behaviour is akin to that of autistic children. However, A.L.I.C.E. type programmes appear on e-commerce Internet sites in a variety of roles; their use will continue to grow as more companies see their deployment as enhancing humancomputer interaction while building brand awareness and increasing sales. ELBOT, Loebner’s 2003 bronze runner up and Chatterbox 2003 winner, is the underlying technology behind text-based dialogical query system Anna, used by Swedish furniture store IKEA. As a virtual customer service agent, NY Wall Street Journal considered it a most useful ACE. As seen in both the Loebner Contests and Chatterbox Challenges, in unrestricted domains these programmes have a long way to go before they are able to constrain their

  2. Reproducibility of MR-based Attenuation Maps in PET/MRI and the Impact on PET Quantification in Lung Cancer

    DEFF Research Database (Denmark)

    Olin, Anders; Ladefoged, Claes N; Langer, Natasha H

    2018-01-01

    AIM: Quantitative positron emission tomography/magnetic resonance imaging (PET/MRI) is dependent upon reliable and reproducible MR-based attenuation correction (MR-AC). In this study we evaluated the quality of current vendor-provided thoracic MR-AC maps, and further investigated...... affecting the reproducibility of PET/MRI. This, in combination with other well-known sources of error associated with PET/MRI examinations, leads to inconsistent SUV measurements in serial studies and follow-up scenarios, which may affect the reliability of therapy response assessment. A thorough visual...

  3. Molecular and recombinational mapping of mutations in the Ace locus of Drosophila melanogaster

    International Nuclear Information System (INIS)

    Nagoshi, R.N.; Gelbart, W.M.

    1987-01-01

    The Ace locus in Drosophila melanogaster is known to be the structural gene for acetylcholinesterase. Ace is located in a region of chromosome arm 3R which has been subjected to intensive genetic and molecular analysis. Previous deletion mapping studies have identified a 40-kb region with which the Ace gene resides. This report focuses on the further localization of Ace within this 40-kb interval. Within this region, selective fine structure recombinational analysis was employed to localize three recessive Ace lethals relative to unselected restriction site variations. These three mutations fall into a segment of 7 kb within the Ace interval. Fine structure recombinational analysis was also used to confirm that the Ace - phenotype of one deletion, Df(3R)Ace/sup HD1/, co-segregated with the molecular deletion. This deletion does not fully remove Ace activity, but it behaves as a recessive Ace lethal. Df(3R)Ace/sup HD1/ is the most distal Ace lesion identified and indicates that the Ace locus must extend at least 16 kb. Several poly(A)transcripts are detectable in the region defined by the Ace lesions. The position and extent of the Ace locus, as well as the types of transcripts found, is consistent with the recent findings which identified Torpedo-AChE homologous cDNA sequences in this region

  4. Listing of Available ACE Data Tables

    Energy Technology Data Exchange (ETDEWEB)

    Conlin, Jeremy Lloyd [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-01-31

    This document is divided into multiple sections. Section 2 lists some of the more frequently used ENDF/B reaction types that can be used with the FM input card. The remaining sections (described below) contain tables showing the available ACE data tables for various types of data. These ACE data libraries are distributed by the Radiation Safety Information Computational Center (RSICC) with MCNP6.

  5. Indeterminate findings on oncologic PET/CT: What difference dose PET/MRI make?

    Energy Technology Data Exchange (ETDEWEB)

    Fraum, Tyler J.; Fowler, Kathryn J.; McConathy, Jonathan; Dehdashti, Farokh [Mallinckrodt Institute of Radiology, Washington University School of Medicine, Saint Louis (United States)

    2016-12-15

    , the definitive PET/MRI interpretation proved correct. These 12 patients underwent six additional diagnostic studies to clarify the initial indeterminate PET/CT findings. In the remaining 13 of 31 cases with indeterminate findings on both PET/CT and PET/MRI, common reasons for uncertainty included the inability to distinguish reactive from malignant lymphadenopathy (4/13) and local recurrence from treatment effect (2/13). Indeterminate PET/CT findings can result in equivocal reads and additional diagnostic studies. PET/MRI may reduce the rate of indeterminate findings by facilitating better tumor staging, FDG activity localization, and lesion characterization. In our study, PET/MRI resulted in more definitive imaging interpretations with high accuracy. PET/MRI also showed potential in reducing the number of additional diagnostic studies prompted by PET/CT findings. Our results suggest that whole-body PET/MRI provides certain diagnostic advantages over PET/CT, promotes more definitive imaging interpretations, and may improve the overall clinical utility of PET.

  6. Indeterminate findings on oncologic PET/CT: What difference dose PET/MRI make?

    International Nuclear Information System (INIS)

    Fraum, Tyler J.; Fowler, Kathryn J.; McConathy, Jonathan; Dehdashti, Farokh

    2016-01-01

    definitive PET/MRI interpretation proved correct. These 12 patients underwent six additional diagnostic studies to clarify the initial indeterminate PET/CT findings. In the remaining 13 of 31 cases with indeterminate findings on both PET/CT and PET/MRI, common reasons for uncertainty included the inability to distinguish reactive from malignant lymphadenopathy (4/13) and local recurrence from treatment effect (2/13). Indeterminate PET/CT findings can result in equivocal reads and additional diagnostic studies. PET/MRI may reduce the rate of indeterminate findings by facilitating better tumor staging, FDG activity localization, and lesion characterization. In our study, PET/MRI resulted in more definitive imaging interpretations with high accuracy. PET/MRI also showed potential in reducing the number of additional diagnostic studies prompted by PET/CT findings. Our results suggest that whole-body PET/MRI provides certain diagnostic advantages over PET/CT, promotes more definitive imaging interpretations, and may improve the overall clinical utility of PET

  7. Imaging of the appearance time of cerebral blood using [15O]H2O PET for the computation of correct CBF.

    Science.gov (United States)

    Kudomi, Nobuyuki; Maeda, Yukito; Sasakawa, Yasuhiro; Monden, Toshihide; Yamamoto, Yuka; Kawai, Nobuyuki; Iida, Hidehiro; Nishiyama, Yoshihiro

    2013-05-23

    Quantification of cerebral blood flow (CBF) is important for the understanding of normal and pathologic brain physiology. Positron emission tomography (PET) with H215O (or C15O2) can quantify CBF and apply kinetic analyses, including autoradiography (ARG) and the basis function methods (BFM). These approaches, however, are sensitive to input function errors such as the appearance time of cerebral blood (ATB), known as the delay time. We estimated brain ATB in an image-based fashion to correct CBF by accounting for differences in computed CBF values using three different analyses: ARG and BFM with and without fixing the partition coefficient. Subject groups included those with no significant disorders, those with elevated cerebral blood volume, and those with reduced CBF. All subjects underwent PET examination, and CBF was estimated using the three analyses. The ATB was then computed from the differences of the obtained CBF values, and ATB-corrected CBF values were computed. ATB was also estimated for regions of interest (ROIs) of multiple cortical regions. The feasibility of the present method was tested in a simulation study. There were no significant differences in the obtained ATB between the image- and ROI-based methods. Significantly later appearance was found in the cerebellum compared to other brain regions for all groups. In cortical regions where CBF was reduced due to occlusive lesions, the ATB was 0.2 ± 1.2 s, which was significantly delayed relative to the contralateral regions. A simulation study showed that the ATB-corrected CBF was less sensitive to errors in input function, and noise on the tissue curve did not enhance the degree of noise on ATB-corrected CBF image. This study demonstrates the potential utility of visualizing the ATB in the brain, enabling the determination of CBF with less sensitivity to error in input function.

  8. Hybrid FDG-PET/MR compared to FDG-PET/CT in adult lymphoma patients.

    Science.gov (United States)

    Atkinson, Wendy; Catana, Ciprian; Abramson, Jeremy S; Arabasz, Grae; McDermott, Shanaugh; Catalano, Onofrio; Muse, Victorine; Blake, Michael A; Barnes, Jeffrey; Shelly, Martin; Hochberg, Ephraim; Rosen, Bruce R; Guimaraes, Alexander R

    2016-07-01

    The goal of this study is to evaluate the diagnostic performance of simultaneous FDG-PET/MR including diffusion compared to FDG-PET/CT in patients with lymphoma. Eighteen patients with a confirmed diagnosis of non-Hodgkin's (NHL) or Hodgkin's lymphoma (HL) underwent an IRB-approved, single-injection/dual-imaging protocol consisting of a clinical FDG-PET/CT and subsequent FDG-PET/MR scan. PET images from both modalities were reconstructed iteratively. Attenuation correction was performed using low-dose CT data for PET/CT and Dixon-MR sequences for PET/MR. Diffusion-weighted imaging was performed. SUVmax was measured and compared between modalities and the apparent diffusion coefficient (ADC) using ROI analysis by an experienced radiologist using OsiriX. Strength of correlation between variables was measured using the Pearson correlation coefficient (r p). Of the 18 patients included in this study, 5 had HL and 13 had NHL. The median age was 51 ± 14.8 years. Sixty-five FDG-avid lesions were identified. All FDG-avid lesions were visible with comparable contrast, and therefore initial and follow-up staging was identical between both examinations. SUVmax from FDG-PET/MR [(mean ± sem) (21.3 ± 2.07)] vs. FDG-PET/CT (mean 23.2 ± 2.8) demonstrated a strongly positive correlation [r s = 0.95 (0.94, 0.99); p < 0.0001]. There was no correlation found between ADCmin and SUVmax from FDG-PET/MR [r = 0.17(-0.07, 0.66); p = 0.09]. FDG-PET/MR offers an equivalent whole-body staging examination as compared with PET/CT with an improved radiation safety profile in lymphoma patients. Correlation of ADC to SUVmax was weak, understating their lack of equivalence, but not undermining their potential synergy and differing importance.

  9. Attenuation correction for freely moving small animal brain PET studies based on a virtual scanner geometry

    International Nuclear Information System (INIS)

    Angelis, G I; Kyme, A Z; Ryder, W J; Fulton, R R; Meikle, S R

    2014-01-01

    Attenuation correction in positron emission tomography brain imaging of freely moving animals is a very challenging problem since the torso of the animal is often within the field of view and introduces a non negligible attenuating factor that can degrade the quantitative accuracy of the reconstructed images. In the context of unrestrained small animal imaging, estimation of the attenuation correction factors without the need for a transmission scan is highly desirable. An attractive approach that avoids the need for a transmission scan involves the generation of the hull of the animal’s head based on the reconstructed motion corrected emission images. However, this approach ignores the attenuation introduced by the animal’s torso. In this work, we propose a virtual scanner geometry which moves in synchrony with the animal’s head and discriminates between those events that traversed only the animal’s head (and therefore can be accurately compensated for attenuation) and those that might have also traversed the animal’s torso. For each recorded pose of the animal’s head a new virtual scanner geometry is defined and therefore a new system matrix must be calculated leading to a time-varying system matrix. This new approach was evaluated on phantom data acquired on the microPET Focus 220 scanner using a custom-made phantom and step-wise motion. Results showed that when the animal’s torso is within the FOV and not appropriately accounted for during attenuation correction it can lead to bias of up to 10% . Attenuation correction was more accurate when the virtual scanner was employed leading to improved quantitative estimates (bias < 2%), without the need to account for the attenuation introduced by the extraneous compartment. Although the proposed method requires increased computational resources, it can provide a reliable approach towards quantitatively accurate attenuation correction for freely moving animal studies. (paper)

  10. Peripheral artery disease: potential role of ACE-inhibitor therapy

    Directory of Open Access Journals (Sweden)

    Giuseppe Coppola

    2008-12-01

    Full Text Available Giuseppe Coppola, Giuseppe Romano, Egle Corrado, Rosa Maria Grisanti, Salvatore NovoDepartment of Internal Medicine, Cardiovascular and Nephro-Urological Diseases, Chair of Cardiovascular Disease, University of Palermo, Palermo, ItalyAbstract: Subjects with peripheral arterial disease (PAD of the lower limbs are at high risk for cardiovascular and cerebrovascular events and the prevalence of coronary artery disease in such patients is elevated. Recent studies have shown that regular use of cardiovascular medications, such as therapeutic and preventive agents for PAD patients, seems to be promising in reducing long-term mortality and morbidity. The angiotensin-converting-enzyme (ACE system plays an important role in the pathogenesis and progression of atherosclerosis, and ACE-inhibitors (ACE-I seem to have vasculoprotective and antiproliferative effects as well as a direct antiatherogenic effect. ACE-I also promote the degradation of bradykinin and the release of nitric oxide, a potent vasodilator; further, thay have shown important implications for vascular oxidative stress. Other studies have suggested that ACE-I may also improve endothelial dysfunction. ACE-I are useful for reducing the risk of cardiovascular events in clinical and subclinical PAD. Particularly, one agent of the class (ie, ramipril has shown in many studies to able to significantly reduce cardiovascular morbidity and mortality in patients with PAD.Keywords: atherosclerosis, peripheral arterial disease, endothelial dysfunction, ACE-inhibitors

  11. Compensation for photon attenuation in PET

    International Nuclear Information System (INIS)

    Chintu Chen; Ordonez, C.E.; Xiaolin Yu.

    1992-01-01

    CT/MR and PET images usually are not in registration spatially because of differences in the imaging setup. CT, MR and PET imaging parameters that are used regularly for brain studies in their institution are compared, in addition, because the patient orientations in CT/MR and PET scanners are not the same, slice centers are positioned differently relative to the patients anatomy. For application of the new idea of using structural information from CT or MR images in PET image reconstruction for attenuation correction, image registration is required as a first step so that one can obtain a corresponding anatomic map for any selected PET image plane. The authors chose to use the surface-matching technique developed in their laboratories for image registration because this method is retrospective and accurate. After the PET and CT/MR scans are registered, they reslice the CT/MR images along the planes of the PET images. The differences in slice thickness and slice separation, as well as in image resolution between various image modalities are to be considered

  12. Sanus-Ace: Negotiating a Memorandum of Understanding in external corporate venturing.

    OpenAIRE

    VANHAVERBEKE, Wim

    2014-01-01

    This negotiation case describes a situation in which an investment manager of a large chemical company (ACE) has to decide about a corporate venturing investment in a small high-tech start-up (Sanus). To win board approval for this investment, an ACE business unit (in this case, ACE Food Specialties) must write a letter of commitment. The investment manager of ACE Venturing cannot invest in the start-up without a MoU between the start-up and the business unit of ACE. This case provides the re...

  13. PET/MRI in the Presence of Metal Implants: Completion of the Attenuation Map from PET Emission Data.

    Science.gov (United States)

    Fuin, Niccolo; Pedemonte, Stefano; Catalano, Onofrio A; Izquierdo-Garcia, David; Soricelli, Andrea; Salvatore, Marco; Heberlein, Keith; Hooker, Jacob M; Van Leemput, Koen; Catana, Ciprian

    2017-05-01

    We present a novel technique for accurate whole-body attenuation correction in the presence of metallic endoprosthesis, on integrated non-time-of-flight (non-TOF) PET/MRI scanners. The proposed implant PET-based attenuation map completion (IPAC) method performs a joint reconstruction of radioactivity and attenuation from the emission data to determine the position, shape, and linear attenuation coefficient (LAC) of metallic implants. Methods: The initial estimate of the attenuation map was obtained using the MR Dixon method currently available on the Siemens Biograph mMR scanner. The attenuation coefficients in the area of the MR image subjected to metal susceptibility artifacts are then reconstructed from the PET emission data using the IPAC algorithm. The method was tested on 11 subjects presenting 13 different metallic implants, who underwent CT and PET/MR scans. Relative mean LACs and Dice similarity coefficients were calculated to determine the accuracy of the reconstructed attenuation values and the shape of the metal implant, respectively. The reconstructed PET images were compared with those obtained using the reference CT-based approach and the Dixon-based method. Absolute relative change (aRC) images were generated in each case, and voxel-based analyses were performed. Results: The error in implant LAC estimation, using the proposed IPAC algorithm, was 15.7% ± 7.8%, which was significantly smaller than the Dixon- (100%) and CT- (39%) derived values. A mean Dice similarity coefficient of 73% ± 9% was obtained when comparing the IPAC- with the CT-derived implant shape. The voxel-based analysis of the reconstructed PET images revealed quantification errors (aRC) of 13.2% ± 22.1% for the IPAC- with respect to CT-corrected images. The Dixon-based method performed substantially worse, with a mean aRC of 23.1% ± 38.4%. Conclusion: We have presented a non-TOF emission-based approach for estimating the attenuation map in the presence of metallic implants, to

  14. Evaluation of PeneloPET Simulations of Biograph PET/CT Scanners

    Science.gov (United States)

    Abushab, K. M.; Herraiz, J. L.; Vicente, E.; Cal-González, J.; España, S.; Vaquero, J. J.; Jakoby, B. W.; Udías, J. M.

    2016-06-01

    Monte Carlo (MC) simulations are widely used in positron emission tomography (PET) for optimizing detector design, acquisition protocols, and evaluating corrections and reconstruction methods. PeneloPET is a MC code based on PENELOPE, for PET simulations which considers detector geometry, acquisition electronics and materials, and source definitions. While PeneloPET has been successfully employed and validated with small animal PET scanners, it required a proper validation with clinical PET scanners including time-of-flight (TOF) information. For this purpose, we chose the family of Biograph PET/CT scanners: the Biograph True-Point (B-TP), Biograph True-Point with TrueV (B-TPTV) and the Biograph mCT. They have similar block detectors and electronics, but a different number of rings and configuration. Some effective parameters of the simulations, such as the dead-time and the size of the reflectors in the detectors, were adjusted to reproduce the sensitivity and noise equivalent count (NEC) rate of the B-TPTV scanner. These parameters were then used to make predictions of experimental results such as sensitivity, NEC rate, spatial resolution, and scatter fraction (SF), from all the Biograph scanners and some variations of them (energy windows and additional rings of detectors). Predictions agree with the measured values for the three scanners, within 7% (sensitivity and NEC rate) and 5% (SF). The resolution obtained for the B-TPTV is slightly better (10%) than the experimental values. In conclusion, we have shown that PeneloPET is suitable for simulating and investigating clinical systems with good accuracy and short computational time, though some effort tuning of a few parameters of the scanners modeled may be needed in case that the full details of the scanners studied are not available.

  15. Impact and correction of the bladder uptake on 18F-FCH PET quantification: a simulation study using the XCAT2 phantom

    Science.gov (United States)

    Silva-Rodríguez, Jesús; Tsoumpas, Charalampos; Domínguez-Prado, Inés; Pardo-Montero, Juan; Ruibal, Álvaro; Aguiar, Pablo

    2016-01-01

    The spill-in counts from neighbouring regions can significantly bias the quantification over small regions close to high activity extended sources. This effect can be a drawback for 18F-based radiotracers positron emission tomography (PET) when quantitatively evaluating the bladder area for diseases such as prostate cancer. In this work, we use Monte Carlo simulations to investigate the impact of the spill-in counts from the bladder on the quantitative evaluation of prostate cancer when using 18F-Fluorcholine (FCH) PET and we propose a novel reconstruction-based correction method. Monte Carlo simulations of a modified version of the XCAT2 anthropomorphic phantom with 18F-FCH biological distribution, variable bladder uptake and inserted prostatic tumours were used in order to obtain simulated realistic 18F-FCH data. We evaluated possible variations of the measured tumour Standardized Uptake Value (SUV) for different values of bladder uptake and propose a novel correction by appropriately adapting image reconstruction methodology. The correction is based on the introduction of physiological background terms on the reconstruction, removing the contribution of the bladder to the final image. The bladder is segmented from the reconstructed image and then forward-projected to the sinogram space. The resulting sinograms are used as background terms for the reconstruction. SUVmax and SUVmean could be overestimated by 41% and 22% respectively due to the accumulation of radiotracer in the bladder, with strong dependence on bladder-to-lesion ratio. While the SUVs measured under these conditions are not reliable, images corrected using the proposed methodology provide better repeatability of SUVs, with biases below 6%. Results also showed remarkable improvements on visual detectability. The spill-in counts from the bladder can affect prostatic SUV measurements of 18F-FCH images, which can be corrected to less than 6% using the proposed methodology, providing reliable SUV

  16. PET/TAC: Basic principles, physiological variants and artifacts

    International Nuclear Information System (INIS)

    Jimenez V, A.M.

    2007-01-01

    This presentation is about the basic principles, physiologic variants and devices that work in the PET/TAC technique. Next the conclusions obtained in the same one are presented: For a correct evaluation of the PET/TAC images with FDG is necessary the knowledge of the image acquisition technique, as well as of the physiologic distribution of the FDG, variants of the normality, benign causes of captation and more frequent devices. The introduction of this hybrid procedure allows the correct anatomical localization and identification of the deposits of FDG largely avoiding false or doubtful interpretations, but it can also originate not specific devices existent in the conventional PET. The previous knowledge of the possible devices will make possible in certain cases its elimination and in other its identification avoiding incorrect interpretations. (Author)

  17. Clinical Usefulness of 18F-fluoride Bone PET

    International Nuclear Information System (INIS)

    Kang, Ji Yeon; Lee, Won Woo; Lee, Byung Chul; Kim, Sang Eun; So, Young

    2010-01-01

    18 F-fluoride bone positron emission tomography (PET) has been reported as a useful bone imaging modality. However, no clinical bone PET study had been performed previously in Korea. The authors investigated the usefulness of 18 F-fluoride bone PET in Korean patients with malignant or benign bone disease. Eighteen consecutive patients (eight women, ten men; mean age, 55±12 years) who had undergone 18 F-fluoride bone PET for the evaluation of bone metastasis (n=13) or benign bone lesions (n=5) were included. The interpretation of bone lesions on 18 F-fluoride bone PET was determined by consensus of two nuclear medicine physicians, and final results were confirmed using combination of all imaging studies and/or clinical follow-up. The analysis was performed on the basis of lesion group. Thirteen patients with malignant disease had 15 lesion groups, among which seven were confirmed as metastatic bone lesions and eight were confirmed as non-metastatic lesions. 18 F-fluoride bone PET correctly identified six of seven metastatic lesions (sensitivity, 86%), and seven of eight non-metastatic lesions (specificity, 88%). On the other hand, five patients with benign conditions had five bone lesion groups; four were confirmed as benign bone diseases and the other one was confirmed as not a bone lesion. 18 F-fluoride bone PET showed correct results in all the five lesion groups. 18 F-fluoride bone PET showed promising potential for bone imaging in Korean patients with malignant diseases as well as with various benign bone conditions. Therefore, further studies are required on the diagnostic performance and cost-effectiveness of 18 F-fluoride bone PET.

  18. SU-E-I-86: Ultra-Low Dose Computed Tomography Attenuation Correction for Pediatric PET CT Using Adaptive Statistical Iterative Reconstruction (ASiR™)

    Energy Technology Data Exchange (ETDEWEB)

    Brady, S; Shulkin, B [St. Jude Children’s Research Hospital, Memphis, TN (United States)

    2015-06-15

    Purpose: To develop ultra-low dose computed tomography (CT) attenuation correction (CTAC) acquisition protocols for pediatric positron emission tomography CT (PET CT). Methods: A GE Discovery 690 PET CT hybrid scanner was used to investigate the change to quantitative PET and CT measurements when operated at ultra-low doses (10–35 mAs). CT quantitation: noise, low-contrast resolution, and CT numbers for eleven tissue substitutes were analyzed in-phantom. CT quantitation was analyzed to a reduction of 90% CTDIvol (0.39/3.64; mGy) radiation dose from baseline. To minimize noise infiltration, 100% adaptive statistical iterative reconstruction (ASiR) was used for CT reconstruction. PET images were reconstructed with the lower-dose CTAC iterations and analyzed for: maximum body weight standardized uptake value (SUVbw) of various diameter targets (range 8–37 mm), background uniformity, and spatial resolution. Radiation organ dose, as derived from patient exam size specific dose estimate (SSDE), was converted to effective dose using the standard ICRP report 103 method. Effective dose and CTAC noise magnitude were compared for 140 patient examinations (76 post-ASiR implementation) to determine relative patient population dose reduction and noise control. Results: CT numbers were constant to within 10% from the non-dose reduced CTAC image down to 90% dose reduction. No change in SUVbw, background percent uniformity, or spatial resolution for PET images reconstructed with CTAC protocols reconstructed with ASiR and down to 90% dose reduction. Patient population effective dose analysis demonstrated relative CTAC dose reductions between 62%–86% (3.2/8.3−0.9/6.2; mSv). Noise magnitude in dose-reduced patient images increased but was not statistically different from pre dose-reduced patient images. Conclusion: Using ASiR allowed for aggressive reduction in CTAC dose with no change in PET reconstructed images while maintaining sufficient image quality for co

  19. PET/MRI for Oncologic Brain Imaging: A Comparison of Standard MR-Based Attenuation Corrections with a Model-Based Approach for the Siemens mMR PET/MR System.

    Science.gov (United States)

    Rausch, Ivo; Rischka, Lucas; Ladefoged, Claes N; Furtner, Julia; Fenchel, Matthias; Hahn, Andreas; Lanzenberger, Rupert; Mayerhoefer, Marius E; Traub-Weidinger, Tatjana; Beyer, Thomas

    2017-09-01

    The aim of this study was to compare attenuation-correction (AC) approaches for PET/MRI in clinical neurooncology. Methods: Forty-nine PET/MRI brain scans were included: brain tumor studies using 18 F-fluoro-ethyl-tyrosine ( 18 F-FET) ( n = 31) and 68 Ga-DOTANOC ( n = 7) and studies of healthy subjects using 18 F-FDG ( n = 11). For each subject, MR-based AC maps (MR-AC) were acquired using the standard DIXON- and ultrashort echo time (UTE)-based approaches. A third MR-AC was calculated using a model-based, postprocessing approach to account for bone attenuation values (BD, noncommercial prototype software by Siemens Healthcare). As a reference, AC maps were derived from patient-specific CT images (CTref). PET data were reconstructed using standard settings after AC with all 4 AC methods. We report changes in diagnosis for all brain tumor patients and the following relative differences values (RDs [%]), with regards to AC-CTref: for 18 F-FET (A)-SUVs as well as volumes of interest (VOIs) defined by a 70% threshold of all segmented lesions and lesion-to-background ratios; for 68 Ga-DOTANOC (B)-SUVs as well as VOIs defined by a 50% threshold for all lesions and the pituitary gland; and for 18 F-FDG (C)-RD of SUVs of the whole brain and 10 anatomic regions segmented on MR images. Results: For brain tumor imaging (A and B), the standard PET-based diagnosis was not affected by any of the 3 MR-AC methods. For A, the average RDs of SUV mean were -10%, -4%, and -3% and of the VOIs 1%, 2%, and 7% for DIXON, UTE, and BD, respectively. Lesion-to-background ratios for all MR-AC methods were similar to that of CTref. For B, average RDs of SUV mean were -11%, -11%, and -3% and of the VOIs 1%, -4%, and -3%, respectively. In the case of 18 F-FDG PET/MRI (C), RDs for the whole brain were -11%, -8%, and -5% for DIXON, UTE, and BD, respectively. Conclusion: The diagnostic reading of PET/MR patients with brain tumors did not change with the chosen AC method. Quantitative accuracy of

  20. [18F]FDG PET/CT outperforms [18F]FDG PET/MRI in differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Vrachimis, Alexis; Wenning, Christian; Weckesser, Matthias; Stegger, Lars; Burg, Matthias Christian; Allkemper, Thomas; Schaefers, Michael

    2016-01-01

    To evaluate the diagnostic potential of PET/MRI with [ 18 F]FDG in comparison to PET/CT in patients with differentiated thyroid cancer suspected or known to have dedifferentiated. The study included 31 thyroidectomized and remnant-ablated patients who underwent a scheduled [ 18 F]FDG PET/CT scan and were then enrolled for a PET/MRI scan of the neck and thorax. The datasets (PET/CT, PET/MRI) were rated regarding lesion count, conspicuity, diameter and characterization. Standardized uptake values were determined for all [ 18 F]FDG-positive lesions. Histology, cytology, and examinations before and after treatment served as the standards of reference. Of 26 patients with a dedifferentiated tumour burden, 25 were correctly identified by both [ 18 F]FDG PET/CT and PET/MRI. Detection rates by PET/CT and PET/MRI were 97 % (113 of 116 lesions) and 85 % (99 of 113 lesions) for malignant lesions, and 100 % (48 of 48 lesions) and 77 % (37 of 48 lesions) for benign lesions, respectively. Lesion conspicuity was higher on PET/CT for both malignant and benign pulmonary lesions and in the overall rating for malignant lesions (p < 0.001). There was a difference between PET/CT and PET/MRI in overall evaluation of malignant lesions (p < 0.01) and detection of pulmonary metastases (p < 0.001). Surgical evaluation revealed three malignant lesions missed by both modalities. PET/MRI additionally failed to detect 14 pulmonary metastases and 11 benign lesions. In patients with thyroid cancer and suspected or known dedifferentiation, [ 18 F]FDG PET/MRI was inferior to low-dose [ 18 F]FDG PET/CT for the assessment of pulmonary status. However, for the assessment of cervical status, [ 18 F]FDG PET/MRI was equal to contrast-enhanced neck [ 18 F]FDG PET/CT. Therefore, [ 18 F]FDG PET/MRI combined with a low-dose CT scan of the thorax may provide an imaging solution when high-quality imaging is needed and high-energy CT is undesirable or the use of a contrast agent is contraindicated. (orig.)

  1. Analysis of whey protein hydrolysates: peptide profile and ACE inhibitory activity

    Directory of Open Access Journals (Sweden)

    Marialice Pinto Coelho Silvestre

    2012-12-01

    Full Text Available The aim of this study was to prepare enzymatic hydrolysates from whey protein concentrate with a nutritionally adequate peptide profile and the ability to inhibit angiotensin-converting enzyme (ACE activity. The effects of the type of enzyme used (pancreatin or papain, the enzyme:substrate ratio (E:S ratio=0.5:100, 1:100, 2:100 and 3:100 and the use of ultrafiltration (UF were investigated. The fractionation of peptides was performed by size-exclusion-HPLC, and the quantification of the components of the chromatographic fractions was carried out by a rapid Corrected Fraction Area method. The ACE inhibitory activity (ACE-IA was determined by Reverse Phase-HPLC. All parameters tested affected both the peptide profile and the ACE-IA. The best peptide profile was achieved for the hydrolysates obtained with papain, whereas pancreatin was more advantageous in terms of ACE-IA. The beneficial effect of using a lower E:S ratio on the peptide profile and ACE-IA was observed for both enzymes depending on the conditions used to prepare the hydrolysates. The beneficial effect of not using UF on the peptide profile was observed in some cases for pancreatin and papain. However, the absence of UF yielded greater ACE-IA only when using papain.O objetivo deste estudo foi preparar hidrolisados enzimáticos do concentrado proteico do soro de leite com perfil peptídico nutricionalmente adequado e com capacidade para inibir a atividade da enzima conversora da angiotensina (ECA. Os efeitos do tipo de enzima usado (pancreatina ou papaína, da relação enzima:substrato (E:S=0,5:100, 1:100, 2:100 e 3:100 e do uso da ultrafiltração (UF foram investigados. O fracionamento dos peptídeos foi feito por CLAE de exclusão molecular e a quantificação dos componentes das frações cromatográficas foi realizada pelo método da Área Corrigida da Fração. A atividade inibitória da ECA (AI-ECA foi determinada por CLAE de fase reversa. Todos os parâmetros testados afetaram

  2. Joint effects of hypertension, smoking, dyslipidemia and obesity and angiotensin-converting enzyme DD genotype on albuminuria in Taiwanese patients with type 2 diabetes mellitus.

    Science.gov (United States)

    Tseng, Chin-Hsiao; Tseng, Ching-Ping; Chong, Choon-Khim

    2010-05-01

    We investigated the individual and joint effects of hypertension, smoking, dyslipidemia, and obesity and angiotensin-converting enzyme (ACE) DD genotype on albuminuria in Taiwanese type 2 diabetic patients. ACE genotypes were determined in 519 (287 men and 232 women) patients aged 58.5 (SD: 9.0) years. Among them, 240 had albuminuria (urinary albumin-to-creatinine ratio > or =30 microg/mg). Logistic regression was used to evaluate the individual and joint effects of risk factors and DD classified by two-by-four table. The adjusted odds ratios were significant for hypertension, smoking and obesity but not for DD and dyslipidemia in models evaluating individual effects. However, while analyzing the joint effects of DD and hypertension, smoking, dyslipidemia and obesity, the respective adjusted odds ratios were 3.253 (1.261-8.391), 3.016 (1.086-8.376), 2.385 (1.010-5.630) and 2.508 (1.117-5.631). Hypertension, smoking, dyslipidemia and obesity jointly play an important role with DD genotype in mediating albuminuria. 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  3. SU-F-R-28: Correction of FCh-PET Bladder Uptake Using Virtual Sinograms and Investigation of Its Impact On the Quantification of Prostate Textural Characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Laberge, S; Beauregard, J; Archambault, L [CHUQ Pavillon Hotel-Dieu de Quebec, Quebec, QC (Canada)

    2016-06-15

    Purpose: Textural biomarkers as a tool for quantifying intratumoral heterogeneity hold great promise for diagnosis and early assessment of treatment response in prostate cancer. However, spill-in counts from the bladder uptake are suspected to have an impact on the textural measurements of the prostate volume. This work proposes a correction method for the FCh-PET bladder uptake and investigates its impact on intraprostatic textural properties. Methods: Two patients with PC received pre-treatment dynamic FCh-PET scans reconstructed at four time points (interval: 2 min), for which prostate and bladder contours were obtained. Projection bins affected by bladder uptake were determined by forward-projection. For each time point and axial position, virtual sinograms were obtained and affected bins replaced by a weighted combination of original values and values interpolated using cubic spline from non-affected bins of the current and adjacent projection angles. The process was optimized using a genetic algorithm in terms of minimization of the root-mean-square error (RMSE) within the bladder between the corrected dynamic time point volume and a reference initial uptake volume. Finally, the impact of the bladder uptake correction on the prostate region was investigated using two standard SUV metrics (1) and three texture metrics (2): 1) SUVmax, SUVmean; 2) Contrast, Homogeneity, Coarseness. Results: Without bladder uptake correction, SUVmax and SUVmean were on average overestimated in the prostate by 0%, 0%, 33.2%, 51.2%, and 3.6%, 6.0%, 2.9%, 3.2%, for each time point respectively. Contrast varied by −9.1%, −6.7%, +40.4%, +107.7%, and Homogeneity and Coarseness by +4.5%, +1.8%, −8.8%, −14.8% and +1.0%, +0.5%, −9.5%, +0.9%. Conclusion: We proposed a method for FCh-PET bladder uptake correction and showed an impact on the quantification of the prostate signal. This method achieved a large reduction of intra-prostatic SUVmax while minimizing the impact on SUVmean

  4. Annual cycle energy system (ACES). Performance report, November 1977-September 1978

    Energy Technology Data Exchange (ETDEWEB)

    Holman, A.S.; Abbatiello, L.A.

    1980-05-01

    A single-family residence near Knoxville, Tennessee, is being used to demonstrate the energy-conserving features of the annual cycle energy system (ACES), an integrated heating and cooling system that utilizes a unidirectional heat pump and low-temperature thermal storage. A second house, the control house, is being used to compare the performance of the ACES with that of an electric-resistance heating and hot-water system combined with a central air conditioning system. The results of one year's operation, from November 1977 through mid-September 1978, showed that the ACES consumed 9012 kWhr of electricity and delivered 40.8 x 10/sup 6/ Btu (43.03 x 10/sup 9/J) of heating, 19.8 x 10/sup 6/ Btu (20.89 x 10/sup 9/J) of hot water, and 24.8 x 10/sup 6/ Btu (26.17 x 10/sup 9/J) of cooling; the annual coefficient of performance (COP) was 2.78. The control house consumed 20,523 kWhr of electricity and delivered 41.3 x 10/sup 6/ Btu (43.57 x 10/sup 9/J) of heating, 14.8 x 10/sup 6/ Btu (15.61 x 10/sup 9/J) of hot water, and 23.2 x 10/sup 6/ Btu (24.41 x 10/sup 9/J) of cooling; the annual COP was 1.13. These loads were delivered in a test year in which the heating season was one of the most severe in the past 20 years and the cooling season was normal. In addition, the ACES reduced peak utility system demands significantly: a reduction from 11.7 to 3.1 kW was achieved in the winter and from 4.1 to 0.7 kW in the summer. The only problems encountered were a heat leak into the storage bin that was twice the calculated value and control logic errors that produced excessive hot water in the winter, requiring extensive use of the night heat-rejection mode in the summer. These problems are currently being corrected.

  5. Angiotensin-converting enzyme (ACE) gene insertion/deletion polymorphism is not a risk factor for hypertension in SLE nephritis.

    Science.gov (United States)

    Negi, Vir S; Devaraju, Panneer; Gulati, Reena

    2015-09-01

    SLE is a systemic autoimmune disease with high prevalence of hypertension. Around 40-75 % of SLE patients develop nephritis, a major cause of hypertension and mortality. Angiotensin-converting enzyme (ACE) maintains the blood pressure and blood volume homeostasis. An insertion/deletion (I/D) polymorphism in intron 16 of ACE gene was reported to influence the development of hypertension, nephritis, and cardiovascular diseases in different ethnic populations. Despite compelling evidence for the high prevalence of hypertension in individuals with SLE, underlying factors for its development are not well studied. With this background, we analyzed the influence of ACE insertion/deletion polymorphism on susceptibility to SLE, development of nephritis and hypertension, other clinical features and autoantibody phenotype in South Indian SLE patients. Three hundred patients with SLE and 460 age and sex similar ethnicity matched individuals were included as patients and healthy controls, respectively. The ACE gene insertion/deletion polymorphism was analyzed by PCR. Insertion (I) and deletion (D) alleles were observed to be equally distributed among patients (57 and 43 %) and controls (59 and 41 %), respectively. The mutant (D) allele did not confer significant risk for SLE (II vs. ID: p = 0.4, OR 1.15, 95 % CI 0.8-1.6; II vs. DD: p = 0.34, OR 1.22, 95 % CI 0.8-1.85). There was no association of the ACE genotype or the allele with development of lupus nephritis (II vs. ID: p = 0.19, OR 1.41, 95 % CI 0.84-2.36; II vs. DD: p = 0.41, OR 0.74, 95 % CI 0.38-1.41) or hypertension (II vs. ID: p = 0.85, OR 0.9, 95 % CI 0.43-1.8; II vs. DD: p = 0.66, OR 1.217, 95 % CI 0.5-2.8). The presence of mutant allele (D) was not found to influence any clinical features or autoantibody phenotype. The insertion/deletion polymorphism of the ACE gene is not a genetic risk factor for SLE and does not influence development of hypertension or lupus nephritis in South Indian

  6. Impact of angiotensin-converting enzyme gene polymorphism on neurohormonal responses to high- versus low-dose enalapril in advanced heart failure.

    Science.gov (United States)

    Tang, W H Wilson; Vagelos, Randall H; Yee, Yin-Gail; Fowler, Michael B

    2004-11-01

    The impact of angiotensin-converting enzyme (ACE) gene polymorphism on neurohormonal dose response to ACE inhibitor therapy is unclear. ACE Insertion (I) or Deletion (D) genotype was determined in 74 patients with chronic heart failure who were randomly assigned to receive either high-dose or low-dose enalapril over a period of 6 months. Monthly pre-enalapril and post-enalapril neurohormone levels (serum ACE activity (sACE), plasma angiotensin II (A-II), plasma renin activity (PRA), and serum aldosterone (ALDO) were compared between genotype subgroups and between patients who received high- or low-dose enalapril within each genotype subgroup. At baseline, predose/postdose sACE and postdose PRA were significantly higher in the DD genotype. At 6-month follow-up, postdose sACE was reduced in a dose-dependent fashion in all three genotypes (P sACE were consistently higher in the DD genotype when compared with ID or II subgroups. Despite a dose-dependent suppression of sACE, there were no observed statistically significant differences in ALDO and A-II suppression or escape with escalating doses of enalapril within each subgroup.

  7. Agile Coalition Environment (ACE)

    National Research Council Canada - National Science Library

    McGuire, Michele; Daniel, Dale

    2004-01-01

    .... Interoperability is achieved across all applications, platforms, and security domains. ACE is presented as a network capability that can be applied to the Coalition Enterprise Information Exchange System (CENTRIXS...

  8. AceCloud: Molecular Dynamics Simulations in the Cloud.

    Science.gov (United States)

    Harvey, M J; De Fabritiis, G

    2015-05-26

    We present AceCloud, an on-demand service for molecular dynamics simulations. AceCloud is designed to facilitate the secure execution of large ensembles of simulations on an external cloud computing service (currently Amazon Web Services). The AceCloud client, integrated into the ACEMD molecular dynamics package, provides an easy-to-use interface that abstracts all aspects of interaction with the cloud services. This gives the user the experience that all simulations are running on their local machine, minimizing the learning curve typically associated with the transition to using high performance computing services.

  9. Generating and verification of ACE-multigroup library for MCNP

    International Nuclear Information System (INIS)

    Chen Chaobin; Hu Zehua; Chen Yixue; Wu Jun; Yang Shouhai

    2012-01-01

    The Monte Carlo code MCNP can handle multigroup calculations and a sample multigroup set based on ENDF/B-V, MGXSNP, is available for MCNP for coupled neutron-photon transport. However, this library is not suit- able for all problems, and there is a need for users to be able to generate multigroup libraries tailored to their specific applications. For these purposes CSPT (cross section processing tool) is created to generate multigroup library for MCNP from deterministic multigroup cross sections (GENDF or ANISN format at present). Several ACE-multigroup libraries based on ENDF/B-VII.0 converted and verified in this work, we drawn the conclusion that the CSPT code works correctly and the libraries produced are credible. (authors)

  10. Methods for discovering and validating relationships among genotyped animals

    Science.gov (United States)

    Genomic selection based on single-nucleotide polymorphisms (SNPs) has led to the collection of genotypes for over 2.2 million animals by the Council on Dairy Cattle Breeding in the United States. To assure that a genotype is assigned to the correct animal and that the animal’s pedigree is correct, t...

  11. The relation between respiratory motion artifact correction and lung standardized uptake value

    International Nuclear Information System (INIS)

    Yin Lijie; Liu Xiaojian; Liu Jie; Xu Rui; Yan Jue

    2014-01-01

    PET/CT is playing an important role in disease diagnosis and therapeutic evaluation. But the respiratory motion artifact may bring trouble in diagnosis and therapy. There are many methods to correct the respiratory motion artifact. Respiratory gated PET/CT is applied most extensively of them. Using respiratory gated PET/CT to correct respiratory motion artifact can increase the maximum standardized uptake value of lung lesion obviously, thereby improving the quality of image and accuracy of diagnosis. (authors)

  12. Simulation-based partial volume correction for dopaminergic PET imaging. Impact of segmentation accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Rong, Ye; Winz, Oliver H. [University Hospital Aachen (Germany). Dept. of Nuclear Medicine; Vernaleken, Ingo [University Hospital Aachen (Germany). Dept. of Psychiatry, Psychotherapy and Psychosomatics; Goedicke, Andreas [University Hospital Aachen (Germany). Dept. of Nuclear Medicine; High Tech Campus, Philips Research Lab., Eindhoven (Netherlands); Mottaghy, Felix M. [University Hospital Aachen (Germany). Dept. of Nuclear Medicine; Maastricht University Medical Center (Netherlands). Dept. of Nuclear Medicine; Rota Kops, Elena [Forschungszentrum Juelich (Germany). Inst. of Neuroscience and Medicine-4

    2015-07-01

    Partial volume correction (PVC) is an essential step for quantitative positron emission tomography (PET). In the present study, PVELab, a freely available software, is evaluated for PVC in {sup 18}F-FDOPA brain-PET, with a special focus on the accuracy degradation introduced by various MR-based segmentation approaches. Methods Four PVC algorithms (M-PVC; MG-PVC; mMG-PVC; and R-PVC) were analyzed on simulated {sup 18}F-FDOPA brain-PET images. MR image segmentation was carried out using FSL (FMRIB Software Library) and SPM (Statistical Parametric Mapping) packages, including additional adaptation for subcortical regions (SPM{sub L}). Different PVC and segmentation combinations were compared with respect to deviations in regional activity values and time-activity curves (TACs) of the occipital cortex (OCC), caudate nucleus (CN), and putamen (PUT). Additionally, the PVC impact on the determination of the influx constant (K{sub i}) was assessed. Results Main differences between tissue-maps returned by three segmentation algorithms were found in the subcortical region, especially at PUT. Average misclassification errors in combination with volume reduction was found to be lowest for SPM{sub L} (PUT < 30%) and highest for FSL (PUT > 70%). Accurate recovery of activity data at OCC is achieved by M-PVC (apparent recovery coefficient varies between 0.99 and 1.10). The other three evaluated PVC algorithms have demonstrated to be more suitable for subcortical regions with MG-PVC and mMG-PVC being less prone to the largest tissue misclassification error simulated in this study. Except for M-PVC, quantification accuracy of K{sub i} for CN and PUT was clearly improved by PVC. Conclusions The regional activity value of PUT was appreciably overcorrected by most of the PVC approaches employing FSL or SPM segmentation, revealing the importance of accurate MR image segmentation for the presented PVC framework. The selection of a PVC approach should be adapted to the anatomical

  13. A temperature-dependent gain control system for improving the stability of Si-PM-based PET systems

    International Nuclear Information System (INIS)

    Yamamoto, Seiichi; Satomi, Junkichi; Watabe, Tadashi; Imaizumi, Masao; Shimosegawa, Eku; Hatazawa, Jun; Watabe, Hiroshi; Kanai, Yasukazu

    2011-01-01

    The silicon-photomultiplier (Si-PM) is a promising photodetector for the development of new PET systems due to its small size, high gain and relatively low sensitivity to the static magnetic field. One drawback of the Si-PM is that it has significant temperature-dependent gain that poses a problem for the stability of the Si-PM-based PET system. To reduce this problem, we developed and tested a temperature-dependent gain control system for the Si-PM-based PET system. The system consists of a thermometer, analog-to-digital converter, personal computer, digital-to-analog converter and variable gain amplifiers in the weight summing board of the PET system. Temperature characteristics of the Si-PM array are measured and the calculated correction factor is sent to the variable gain amplifier. Without this correction, the temperature-dependent peak channel shifts of the block detector were -55% from 20 deg. C to 35 deg.C. With the correction, the peak channel variations were corrected within ±8%. The coincidence count rate of the Si-PM-based PET system was measured using a Na-22 point source while monitoring the room temperature. Without the correction, the count rate inversely changed with the room temperature by 10% for 1.5 deg. C temperature changes. With the correction, the count rate variation was reduced to within 3.7%. These results indicate that the developed temperature-dependent gain control system can contribute to improving the stability of Si-PM-based PET systems.

  14. [F-18]FDG imaging of head and neck tumors: comparison of hybrid PET, dedicated PET and CT

    International Nuclear Information System (INIS)

    Dresel, S.; Brinkbaeumer, K.; Schmid, R.; Poepperl, G.; Hahn, K.; Szeimies, U.

    2001-01-01

    Aim: Aim of the study was to evaluate [F-18]FDG imaging of head and neck tumors using a Hybrid-PET device of the 2nd or 3rd generation. Examinations were compared to dedicated PET and Spiral-CT. Methods: 54 patients suffering from head and neck tumors were examined using dedicated PET and Hybrid-PET after injection of 185-350 MBq [F-18]FDG. Examinations were carried out on the dedicated PET first followed by a scan on the Hybrid-PET. Dedicated PET was acquired in 3D mode, Hybrid-PET was performed in list mode using an axial filter. Reconstruction of data was performed iteratively on both, dedicated PET and Hybrid-PET. All patients received a CT scan in multislice technique. All finding have been verified by the goldstandard histology or in case of negative histology by follow up. Results: Using dedicated PET the primary or recurrent lesion was correctly diagnosed in 47/48 patients, using Hybrid-PET in 46/48 patients and using CT in 25/48 patients. Metastatic disease in cervical lymph nodes was diagnosed in 17/18 patients with dedicated PET, in 16/18 patients with Hybrid-PET and in 15/18 with CT. False positive results with regard to lymph node metastasis were seen with one patient for dedicated PET and Hybrid-PET, respectively, and with 18 patients for CT. In a total of 11 patients unknown metastastic lesions were seen with dedicated PET and with Hybrid-PET elsewhere in the body. Additional malignant disease other than the head and neck tumor was found in 4 patients. Conclusion: Using Hybrid-PET for [F-18]FDG imaging reveals a loss of sensitivity and specificity of about 1-5% as compared to dedicated PET in head and neck tumors. [F-18]FDG PET with both, dedicated PET and Hybrid-PET is superior to CT in the diagnosis of primary or recurrent lesions as well as in the assessment of lymph node involvement. (orig.) [de

  15. MR-based attenuation correction for PET/MRI neurological studies with continuous-valued attenuation coefficients for bone through a conversion from R2* to CT-Hounsfield units.

    Science.gov (United States)

    Juttukonda, Meher R; Mersereau, Bryant G; Chen, Yasheng; Su, Yi; Rubin, Brian G; Benzinger, Tammie L S; Lalush, David S; An, Hongyu

    2015-05-15

    MR-based correction for photon attenuation in PET/MRI remains challenging, particularly for neurological applications requiring quantitation of data. Existing methods are either not sufficiently accurate or are limited by the computation time required. The goal of this study was to develop an MR-based attenuation correction method that accurately separates bone tissue from air and provides continuous-valued attenuation coefficients for bone. PET/MRI and CT datasets were obtained from 98 subjects (mean age [±SD]: 66yrs [±9.8], 57 females) using an IRB-approved protocol and with informed consent. Subjects were injected with 352±29MBq of (18)F-Florbetapir tracer, and PET acquisitions were begun either immediately or 50min after injection. CT images of the head were acquired separately using a PET/CT system. Dual echo ultrashort echo-time (UTE) images and two-point Dixon images were acquired. Regions of air were segmented via a threshold of the voxel-wise multiplicative inverse of the UTE echo 1 image. Regions of bone were segmented via a threshold of the R2* image computed from the UTE echo 1 and UTE echo 2 images. Regions of fat and soft tissue were segmented using fat and water images decomposed from the Dixon images. Air, fat, and soft tissue were assigned linear attenuation coefficients (LACs) of 0, 0.092, and 0.1cm(-1), respectively. LACs for bone were derived from a regression analysis between corresponding R2* and CT values. PET images were reconstructed using the gold standard CT method and the proposed CAR-RiDR method. The RiDR segmentation method produces mean Dice coefficient±SD across subjects of 0.75±0.05 for bone and 0.60±0.08 for air. The CAR model for bone LACs greatly improves accuracy in estimating CT values (28.2%±3.0 mean error) compared to the use of a constant CT value (46.9%±5.8, punits. From our analysis, we conclude that the proposed method closely approaches (<3% error) the gold standard CT-scaled method in PET reconstruction accuracy

  16. PET-Tool: a software suite for comprehensive processing and managing of Paired-End diTag (PET sequence data

    Directory of Open Access Journals (Sweden)

    Wei Chia-Lin

    2006-08-01

    Full Text Available Abstract Background We recently developed the Paired End diTag (PET strategy for efficient characterization of mammalian transcriptomes and genomes. The paired end nature of short PET sequences derived from long DNA fragments raised a new set of bioinformatics challenges, including how to extract PETs from raw sequence reads, and correctly yet efficiently map PETs to reference genome sequences. To accommodate and streamline data analysis of the large volume PET sequences generated from each PET experiment, an automated PET data process pipeline is desirable. Results We designed an integrated computation program package, PET-Tool, to automatically process PET sequences and map them to the genome sequences. The Tool was implemented as a web-based application composed of four modules: the Extractor module for PET extraction; the Examiner module for analytic evaluation of PET sequence quality; the Mapper module for locating PET sequences in the genome sequences; and the ProjectManager module for data organization. The performance of PET-Tool was evaluated through the analyses of 2.7 million PET sequences. It was demonstrated that PET-Tool is accurate and efficient in extracting PET sequences and removing artifacts from large volume dataset. Using optimized mapping criteria, over 70% of quality PET sequences were mapped specifically to the genome sequences. With a 2.4 GHz LINUX machine, it takes approximately six hours to process one million PETs from extraction to mapping. Conclusion The speed, accuracy, and comprehensiveness have proved that PET-Tool is an important and useful component in PET experiments, and can be extended to accommodate other related analyses of paired-end sequences. The Tool also provides user-friendly functions for data quality check and system for multi-layer data management.

  17. Angiotensin I-Converting Enzyme (ACE Inhibitory Activity and ACE Inhibitory Peptides of Salmon (Salmo salar Protein Hydrolysates Obtained by Human and Porcine Gastrointestinal Enzymes

    Directory of Open Access Journals (Sweden)

    Małgorzata Darewicz

    2014-08-01

    Full Text Available The objectives of the present study were two-fold: first, to detect whether salmon protein fractions possess angiotensin I-converting enzyme (ACE inhibitory properties and whether salmon proteins can release ACE inhibitory peptides during a sequential in vitro hydrolysis (with commercial porcine enzymes and ex vivo digestion (with human gastrointestinal enzymes. Secondly, to evaluate the ACE inhibitory activity of generated hydrolysates. A two-step ex vivo and in vitro model digestion was performed to simulate the human digestion process. Salmon proteins were degraded more efficiently by porcine enzymes than by human gastrointestinal juices and sarcoplasmic proteins were digested/hydrolyzed more easily than myofibrillar proteins. The ex vivo digested myofibrillar and sarcoplasmic duodenal samples showed IC50 values (concentration required to decrease the ACE activity by 50% of 1.06 and 2.16 mg/mL, respectively. The in vitro hydrolyzed myofibrillar and sarcoplasmic samples showed IC50 values of 0.91 and 1.04 mg/mL, respectively. Based on the results of in silico studies, it was possible to identify 9 peptides of the ex vivo hydrolysates and 7 peptides of the in vitro hydrolysates of salmon proteins of 11 selected peptides. In both types of salmon hydrolysates, ACE-inhibitory peptides IW, IY, TVY and VW were identified. In the in vitro salmon protein hydrolysates an ACE-inhibitory peptides VPW and VY were also detected, while ACE-inhibitory peptides ALPHA, IVY and IWHHT were identified in the hydrolysates generated with ex vivo digestion. In our studies, we documented ACE inhibitory in vitro effects of salmon protein hydrolysates obtained by human and as well as porcine gastrointestinal enzymes.

  18. Comparison of Imaging Characteristics of 124I PET for Determination of Optimal Energy Window on the Siemens Inveon PET

    Directory of Open Access Journals (Sweden)

    A Ram Yu

    2016-01-01

    Full Text Available Purpose.124I has a half-life of 4.2 days, which makes it suitable for imaging over several days over its uptake and washout phases. However, it has a low positron branching ratio (23%, because of prompt gamma coincidence due to high-energy γ-photons (602 to 1,691 keV, which are emitted in cascade with positrons. Methods. In this study, we investigated the optimal PET energy window for 124I PET based on image characteristics of reconstructed PET. Image characteristics such as nonuniformities, recovery coefficients (RCs, and the spillover ratios (SORs of 124I were measured as described in NEMA NU 4-2008 standards. Results. The maximum and minimum prompt gamma coincidence fraction (PGF were 33% and 2% in 350~800 and 400~590 keV, respectively. The difference between best and worst uniformity in the various energy windows was less than 1%. The lowest SORs of 124I were obtained at 350~750 keV in nonradioactive water compartment. Conclusion. Optimal energy window should be determined based on image characteristics. Our developed correction method would be useful for the correction of high-energy prompt gamma photon in 124I PET. In terms of the image quality of 124I PET, our findings indicate that an energy window of 350~750 keV would be optimal.

  19. PET/CT colonography in patients with colorectal polyps: a feasibility study

    International Nuclear Information System (INIS)

    Mainenti, Pier P.; Pace, Leonardo; Salvatore, Marco; Salvatore, Barbara; D'Antonio, Dario; Bucci, Luigi; De Falco, Teresa; De Palma, Giovanni D.; D'Armiento, Francesco P.

    2007-01-01

    To examine: (1) the feasibility of PET/CT colonography (PET/CTc) in patients with colorectal polyps; (2) the impact of metabolic information on CTc interpretation and, conversely, the impact of morphological information on PET characterisation of focal colorectal uptake. Ten patients with colorectal polyps underwent PET/CTc, followed within 3 h by therapeutic conventional colonoscopy (CC). A radiologist and a nuclear medicine physician analysed the PET/CTc images. The agreement of morphological and metabolic information in the colon and rectum was evaluated. The sensitivity and specificity of PET, CT and PET/CT were calculated for colorectal polyps. Seventeen polypoid lesions were identified at CC: six≤5 mm, six between 6 and 9 mm, and five ≥10 mm (four hyperplastic polyps, 11 tubular adenomas, one adenocarcinoma and one submucosal lipoma). A total of 20 scans (supine and prone) were performed in the ten patients: the agreement of morphological and metabolic information was excellent in 17 scans, good in two and moderate in one. PET/CTc showed a sensitivity of 91% for lesions ≥6 mm and a specificity of 100%. The metabolic information did not disclose any further polyps missed on CTc. The morphological information permitted correct classification of all eight instances of focal radiotracer uptake. PET/CTc is a feasible study. Adding a colonographic protocol to PET/CT images seems to allow correct characterisation of all cases of colorectal focal radiotracer uptake. The metabolic information does not seem to increase the accuracy of CTc. (orig.)

  20. Selected PET radiomic features remain the same.

    Science.gov (United States)

    Tsujikawa, Tetsuya; Tsuyoshi, Hideaki; Kanno, Masafumi; Yamada, Shizuka; Kobayashi, Masato; Narita, Norihiko; Kimura, Hirohiko; Fujieda, Shigeharu; Yoshida, Yoshio; Okazawa, Hidehiko

    2018-04-17

    We investigated whether PET radiomic features are affected by differences in the scanner, scan protocol, and lesion location using 18 F-FDG PET/CT and PET/MR scans. SUV, TMR, skewness, kurtosis, entropy, and homogeneity strongly correlated between PET/CT and PET/MR images. SUVs were significantly higher on PET/MR 0-2 min and PET/MR 0-10 min than on PET/CT in gynecological cancer ( p = 0.008 and 0.008, respectively), whereas no significant difference was observed between PET/CT, PET/MR 0-2 min , and PET/MR 0-10 min images in oral cavity/oropharyngeal cancer. TMRs on PET/CT, PET/MR 0-2 min , and PET/MR 0-10 min increased in this order in gynecological cancer and oral cavity/oropharyngeal cancer. In contrast to conventional and histogram indices, 4 textural features (entropy, homogeneity, SRE, and LRE) were not significantly different between PET/CT, PET/MR 0-2 min , and PET/MR 0-10 min images. 18 F-FDG PET radiomic features strongly correlated between PET/CT and PET/MR images. Dixon-based attenuation correction on PET/MR images underestimated tumor tracer uptake more significantly in oral cavity/oropharyngeal cancer than in gynecological cancer. 18 F-FDG PET textural features were affected less by differences in the scanner and scan protocol than conventional and histogram features, possibly due to the resampling process using a medium bin width. Eight patients with gynecological cancer and 7 with oral cavity/oropharyngeal cancer underwent a whole-body 18 F-FDG PET/CT scan and regional PET/MR scan in one day. PET/MR scans were performed for 10 minutes in the list mode, and PET/CT and 0-2 min and 0-10 min PET/MR images were reconstructed. The standardized uptake value (SUV), tumor-to-muscle SUV ratio (TMR), skewness, kurtosis, entropy, homogeneity, short-run emphasis (SRE), and long-run emphasis (LRE) were compared between PET/CT, PET/MR 0-2 min , and PET/MR 0-10 min images.