WorldWideScience

Sample records for personnel contamination monitors

  1. Automatic personnel contamination monitor

    International Nuclear Information System (INIS)

    Lattin, Kenneth R.

    1978-01-01

    United Nuclear Industries, Inc. (UNI) has developed an automatic personnel contamination monitor (APCM), which uniquely combines the design features of both portal and hand and shoe monitors. In addition, this prototype system also has a number of new features, including: micro computer control and readout, nineteen large area gas flow detectors, real-time background compensation, self-checking for system failures, and card reader identification and control. UNI's experience in operating the Hanford N Reactor, located in Richland, Washington, has shown the necessity of automatically monitoring plant personnel for contamination after they have passed through the procedurally controlled radiation zones. This final check ensures that each radiation zone worker has been properly checked before leaving company controlled boundaries. Investigation of the commercially available portal and hand and shoe monitors indicated that they did not have the sensitivity or sophistication required for UNI's application, therefore, a development program was initiated, resulting in the subject monitor. Field testing shows good sensitivity to personnel contamination with the majority of alarms showing contaminants on clothing, face and head areas. In general, the APCM has sensitivity comparable to portal survey instrumentation. The inherit stand-in, walk-on feature of the APCM not only makes it easy to use, but makes it difficult to bypass. (author)

  2. Monitoring of overalls and personnel skin contamination

    International Nuclear Information System (INIS)

    Turkin, N.F.

    1980-01-01

    Organization of monitoring of overalls and personnel skin contamination wastes is considered. The devices used for this purpose are enumerated. In sanitary sluices through which the personnel leaving the repair zone it is recommended to particularly thoroughly control hand skin contamination and most contaminated parts of overalls (sleeves, breeches lower parts, pockets, stomack region). In sanitary check points during personnel leaving the operator zone monitoring of overalls and skin contamination is performed. The overalls and other individual protective clothing are subjected to control in a special loundry before and after washing (decontamination) [ru

  3. Testing of portal monitors for personnel contamination control

    International Nuclear Information System (INIS)

    Johnson, L.O.; Gupta, V.P.; Stevenson, R.L.; Stalker, A.C.; Baker, K.R.; Littleton, M.L.; Rich, B.L.

    1983-04-01

    This is a report of an INPO-funded evaluation of state-of-the-art portal monitors used to detect personnel contamination. The project developed techniques and procedures to evaluate the performance and sensitivity of the portal monitors which provided data for intercomparison. An additional accomplishment was development of a methodology to assist manufacturers and users to optimize the monitor settings, and to provide technical basis for the eventual use of fixed monitors to replace frisking for contamination control. The monitors tested utilize thin-window gas-flow proportional counters sensitive to beta and gamma radiation. Various tests were performed: (1) background count rate and the statistical variability, (2) detector efficiency at different distances, (3) moving source sensitivity for various size sources and speeds, and (4) false alarm rates at different background levels. A model has been developed for the moving source measurements to compare the experimental data, and to test whether it is possible to adequately model the behavior of a portal monitor response to a moving source. The model results with the actual test results are compared

  4. Personnel monitoring

    International Nuclear Information System (INIS)

    1965-01-01

    This film stresses the need for personnel monitoring in work areas where there is a hazard of exposure to radiation. It illustrates the use of personnel monitoring devices (specially the film dosimeter), the assessment of exposure to radiation and the detailed recording of the results on personnel filing cards

  5. Personnel monitoring

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1966-12-31

    This film stresses the need for personnel monitoring in work areas where there is a hazard of exposure to radiation. It illustrates the use of personnel monitoring devices (specially the film dosimeter), the assessment of exposure to radiation and the detailed recording of the results on personnel filing cards

  6. Scanning personnel for internal deposition of radioactive material with personnel contamination whole body friskers and portal monitors

    International Nuclear Information System (INIS)

    Lobdell, J.L.

    1996-01-01

    The potential for using personnel contamination devices such as whole body friskers and portal monitors for internal contamination monitoring was evaluated. Internally deposited radioactive material is typically determined with whole body counting systems. Whole body counts have traditionally been performed on personnel when they report for work, on a periodic basis (i.e., annually), when an uptake is suspected, and on termination. These counts incur significant expense. The monitored personnel pass through whole body friskers and portal monitors daily. This investigation was performed to determine if the external contamination monitors could provide an alternative to the more Costly whole body counting. The ability to detect 1% of a DAC for critical radioisotopes was applied as a detection criteria for this investigation. The results of whole body counts were used to identify the typical internal contamination radionuclides. From this list, the radioisotopes that would be the most difficult to measure were identified. From this review, 60 Co and 131 I were determined to be the critical radionuclides. One percent of a DAC for each isotope was placed, one at a time, in a humanoid phantom. The phantom was placed in the whole body frisker and open-quotes countedclose quotes. The phantom was carried through the portal monitor at a speed equivalent to a person walking through the monitor. Frequency of detection was derived for both systems. Practical aspects of integrating this screening system with traditional internal dosimetry programs are discussed

  7. Personnel Monitoring Department - DEMIN

    International Nuclear Information System (INIS)

    1989-01-01

    The activities and purposes of the Personnel Monitoring Dept. of the Institute of Radioprotection and Dosimetry of the Brazilian CNEN are presented. A summary of the personnel monitoring service is given, such as dosemeters supply, laboratorial inspections, and so on. The programs of working, publishing, courses and personnel interchange are also presented. (J.A.M.M.)

  8. Radiation contamination monitors

    International Nuclear Information System (INIS)

    Kato, Tsutomu; Iba, Hiroshi; Sato, Hiroshi

    1999-01-01

    To make sure of no contamination on people, used articles and working uniforms coming out of the radiation controlled area, nuclear power plants are equipped with radioactive contamination monitors. This paper outlines the basic specifications and advantages of our personnel surface contamination monitors to inspect whole-body surface contamination of people coming out, article surface contamination monitors to inspect the surface and inside contamination of used articles brought out, laundry monitors to inspect surface contamination of working uniforms used in the area before and after a wash, and whole-body counters to inspect and measure the internal contamination of a person out of the area. (author)

  9. Quo vadis, personnel monitoring

    International Nuclear Information System (INIS)

    Becker, K.

    1975-01-01

    With the increasing use of nuclear power and radiation sources, the selection of optimum systems for personnel monitoring is becoming a matter of worldwide concern. The present status of personnel dosimetry, sometimes characterized by unstable and inaccurate detectors and oversimplified interpretation of the results, leaves much to be desired. In particular, photographic film, although having certain advantages with regard to economics and information content, undergoes rapid changes in warm and humid climates. Careful sealing reduces, but does not prevent, these problems. The replacement of film by solid-state dosimeters, primarily thermoluminescence dosimeters, is in progress or being considered by an increasing number of institutions and requires a number of decisions concerning the choice of the optimum detector(s), badge design, and evaluation system; organizational matters, such as the desirability of automation and computerized bookkeeping; etc. The change also implies the potential use of such advanced concepts as different detectors and monitoring periods for the large number of low-risk persons and the small number of high-risk radiation workers. (auth)

  10. Dosimetric Aspects of Personnel Skin Contamination by Radionuclides - Estimate of a Skin Dose, Monitoring and Interpretation of Results

    International Nuclear Information System (INIS)

    Husak, V.; Kleinbauer, K.

    2001-01-01

    Full text: On the basis of a critical comparison of literary data, tables are compiled of beta and gamma dose rate in mSvh -1 (kBqcm -1 ) to the basal layer of the skin at 0.07 mm depth from contamination by 75 radionuclides unsealed sources; radioactive substances are assumed to reside on the skin surface. The residence time needed for the estimate of the skin dose is calculated assuming that a residual activity per unit area of any radionuclide on the skin, which could not be removed by the repeated careful decontamination, is supposed to be eliminated with the biological half-life of 116 h as a consequence of the natural sloughing off of the skin. Radionuclides are divided into five groups according to the dose estimate in mSv (kBqcm -2 ): ≥250 (e.g. 32 P, 89 Sr, 137 Cs/ 137m Ba), 100-250 (e.g. 90 Y, 131 I, 186 Re), 10-100 (e.g. 35 S, 67 Ga, 200 Tl), 1-10 (e.g. 18 F, 51 Cr, 99m Tc), ≤1 (e.g. 63 Ni, 144 Pr, 238 U). If it is possible, doses can be determined more precisely by measuring the effective half-life of the residual activity on the contaminated area. Our dose estimates are approximately valid on the condition that, after decontamination, residual activity of radionuclides persists predominantly in the superficial layers of epidermis. This and further uncertainties connected with the dose assessment are discussed. Our tables can help to determine easily rough values of doses to personnel in contamination incidents and to interpret them in relation to regulatory derived limits. This work was supported by State Office for Nuclear Safety in Prague. (author)

  11. Personnel monitoring in geologic fields

    International Nuclear Information System (INIS)

    Romanova, I.N.; Seredin, Yu.V.

    1981-01-01

    State of radiation safety for the personnel of geologic crews carrying out neutron logging of wells using Po-Be sources has been evaluated. Given are results of development of methods for the evaluation of individual radiation loads for personnel when working with Po-Be neutron sources useful for the application in practice by a geologic logging crew as well as a quantitative evaluation of profissional radiation loads during this kind of work. The following methods are recommended for personnel monitoring: 1) calculation of whole-body irradiation doses and hands from averaged values of radiation dose rate; 2) calculational tabulated determination of irradiation doses during recharging of shanks of well instruments. Personnel monitoring by means of instrumental methods is not necessary in the considered case [ru

  12. Personnel external dose monitoring system

    International Nuclear Information System (INIS)

    Zhao Hengyuan

    1989-01-01

    The status and trend of personnel external dose monitoring system are introduced briefly. Their characteristics, functions and TLD bedges of some commercially available automatic TLD system, including UD-710A (Matsushita, Japan), Harshaw-2271, 2276 (Harshaw, USA), Harshaw-8000 (Harshaw/Filtrol), Studsvik-1313 (Sweden) and Pitman-800 (UK) were depicted in detail. Finally, personnel dose management and record keeping system were presented and two examples were given

  13. Monitoring of the internal contamination of occupationally exposure personnel in services of nuclear medicine through the use of gamma cameras

    International Nuclear Information System (INIS)

    Teran, M.; Paolino, A.; Savio, E.; Hermida, J.C.; Dantas, B.M.

    2006-01-01

    The radionuclides incorporation can happen as a result of diverse activities; these include the work associated with the different stadiums of the nuclear fuel cycle, the use of radioactive sources in medicine, the scientific research, the agriculture and the industry. In Uruguay the main activities linked to the manipulation of open sources correspond those of Nuclear Medicine and from 2004, in the mark of the Project Arcal RLA 049 and being based on the Safety Guides of the IAEA it is implementing a program of internal monitoring in combined form the Nuclear Medicine Center of the Hospital of and the Radiochemistry class of the Faculty of Chemistry. In accordance with the publication of the ICRP 75 the emphasis of any monitoring program should be in the formal study of the doses in the workers to who are considered commendable of to receive in routine form an outstanding fraction of the dose limits or who work in areas where the exposures can be significant in the accident event. From April 2004, to the date has started a pilot plan by means of in that were established appropriate conditions of procedures and of safety in a reduced group of workers of the Nuclear Medicine area. In that period the first work limits, equipment adjustment, calibrations and registration systems were determined. The monitoring system implemented until the moment is carried out with a thyroid caption equipment. However these measurements are carried out in the university hospital embracing 40% of the involved workers of our country, with the purpose of reaching the covering of the biggest quantity of occupationally exposed personnel of private clinics. Also it was developed a new work proposal that allows to have an alternative measure method, in the event of not having the equipment habitually used. Among the conclusions of this work are that for the before exposed are considered the measure conditions but appropriate the following ones: Gamma Camera without collimator; Measurement

  14. Radioactive surface contamination monitors

    International Nuclear Information System (INIS)

    Aoyama, Kei; Minagoshi, Atsushi; Hasegawa, Toru

    1994-01-01

    To reduce radiation exposure and prevent contamination from spreading, each nuclear power plant has established a radiation controlled area. People and articles out of the controlled area are checked for the surface contamination of radioactive materials with surface contamination monitors. Fuji Electric has repeatedly improved these monitors on the basis of user's needs. This paper outlines typical of a surface contamination monitor, a personal surface contamination monitor, an article surface contamination monitor and a laundry monitor, and the whole-body counter of an internal contamination monitor. (author)

  15. Trust versus confidence: Microprocessors and personnel monitoring

    International Nuclear Information System (INIS)

    Chiaro, P.J. Jr.

    1993-01-01

    Due to recent technological advances, substantial improvements have been made in personnel contamination monitoring. In all likelihood, these advances will close out the days of manually frisking personnel for radioactive contamination. Unfortunately, as microprocessor-based monitors become more widely used, not only at commercial power reactors but also at government facilities, questions concerning their trustworthiness arise. Algorithms make decisions that were previously made by technicians. Trust is placed not in technicians but in machines. In doing this it is assumed that the machine never misses. Inevitably, this trust drops, due largely to open-quotes false alarms.close quotes This is especially true when monitoring for alpha contamination. What is a open-quotes false alarm?close quotes Do these machines and their algorithms that we put our trust in make mistakes? An analysis was performed on half-body and hand-and-foot monitors at Oak Ridge National Laboratory (ORNL) in order to justify the suggested confidence level used for alarm point determination. Sources used in this analysis had activities approximating ORNL's contamination limits

  16. Trust versus confidence: Microprocessors and personnel monitoring

    International Nuclear Information System (INIS)

    Chiaro, P.J. Jr.

    1993-01-01

    Due to recent technological advances, substantial improvements have been made in personnel contamination monitoring. In all likelihood, these advances will close out the days of manually frisking personnel for radioactive contamination. Unfortunately, as microprocessor-based monitors become more widely used, not only at commercial power reactors but also at government facilities, questions concerning their trustworthiness arise. Algorithms make decisions that were previously made by technicians. Trust is placed not in technicians but in machines. In doing this it is assumed that the machine never misses. Inevitably, this trust drops, due largely to ''false alarms''. This is especially true when monitoring for alpha contamination. What is a ''false alarm''? Do these machines and their algorithms that we put our trust in make mistakes? An analysis was performed on half-body and hand-and-foot monitors at Oak Ridge National Laboratory (ORNL) in order to justify the suggested confidence level used for alarm point determination. Sources used in this analysis had activities approximating ORNL's contamination limits

  17. Trust versus confidence: Microprocessors and personnel monitoring

    International Nuclear Information System (INIS)

    Chiaro, P.J. Jr.

    1994-01-01

    Due to recent technological advances, substantial improvements have been made in personnel contamination monitoring. In all likelihood, these advances will close out the days of manually frisking personnel for radioactive contamination. Unfortunately, as microprocessor-based monitors become more widely used, not only at commercial power reactors but also at government facilities, questions concerning their trustworthiness arise. Algorithms make decisions that were previously made by technicians. Trust is placed not in technicians but in machines. In doing this it is assumed that the machine never misses. Inevitably, this trust drops, due largely to ''false alarms''. This is especially true when monitoring for alpha contamination. What is a ''false alarm''? Do these machines and their algorithms that they put their trust in make mistakes? An analysis was performed on half-body and hand-and-foot monitors at Oak Ridge National Laboratory (ORNL) in order to justify the suggested confidence level used for alarm point determination. Sources used in this analysis had activities approximating ORNL's contamination limits

  18. Personnel monitoring for beta rays

    International Nuclear Information System (INIS)

    Piesch, E.; Johns, T.F.

    1983-01-01

    The practical considerations which have to be taken into account in the design of personnel monitors intended to measure doses resulting from exposure to beta rays are discussed. These include the measurement of doses in situations involving either fairly uniform or non-uniform irradiation and of doses to the male gonads. (UK)

  19. Contamination monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Alamares, A L [Philippine Nuclear Research Inst., Diliman, Quezon City (Philippines)

    1997-06-01

    By virture of Republic Act 2067, as amended the Philippine Atomic Energy Commission (PAEC), now renamed Philippine Nuclear Research Institute (PNRI) is the government agency charged with the regulations and control of radioactive materials in the Philippines. The protection against the hazards of non-ionizing radiation is being monitored by the Radiological Health Service (RHS) of the Department of Health pursuant to the provision of Presidental Decree 480. The RHS issues licenses for possession, handling, and use of x-ray machines and equipment, both industrial and medical, and provide radiation protection training to x-ray technologists and technicians. As part of its regulatory function, the PNRI is charged with the responsibility of assuring that the radiation workers and the public are protected from the hazards associated with the possession, handling, production, manufacturing, and the use of radioactive materials and atomic energy facilities in the Philippines. The protection of radiation workers from the hazards of ionizing radiation has always been a primary concern of PNRI and by limiting the exposure of radiation workers, the risk to population is kept to within acceptable level. In this paper, the following items are described: radiation protection program, radiation protection services, radiation control, and problems encountered/recommendation. (G.K.)

  20. Psychological aspects of personnel contamination

    International Nuclear Information System (INIS)

    Wilson, R.L.

    1985-04-01

    This paper discusses some of the major emotional considerations involved in the treatment of people who have been contaminated with potentially hazardous materials. Although the principal focus is the treatment of people trained to work with these materials, an attempt is also made to extend these methods to people having little or no knowledge of such matters. Accidents always result in emotional trauma. When the accident involves radioactive or other potentially toxic, carcinogenic, or mutagenic materials, there is a possibility of enhanced emotional stress due to the mystique surrounding these substances. Several psychological principles that have emerged from the treatment of radioactively-contaminated workers are: (1) provide pre-accident training for all radiation workers; (2) avoid secrets; (3) as rapidly as possible following a contamination accident, bring the worker into contact with others; (4) recognize the emotions of the family and the family's fears and trauma; and (5) do not desert the worker after decontamination has been completed. 1 ref

  1. Whole body personnel monitoring via ionization detection

    International Nuclear Information System (INIS)

    Koster, J.E.; Bounds, K.A.; Kerr, P.L.; Steadman, P.A.; Whitley, C.R.

    1998-02-01

    A project between Fernald EMP and LANL is to field a monitor for the detection of alpha-emitting contamination on a human body. Traditional personnel monitoring for alpha emitters involves either frisking with a probe or pressing against large detectors in order to overcome the short range of alpha particles. These methods have a low alpha collection efficiency, and can miss contamination on less accessible surfaces. The authors have investigated the sensitivity and practicality of measuring the entire subject simultaneously using the technique of ionization monitoring. The goal is to create a booth that personnel step into quickly during egress from radiological facilities. The detection technique relies on a breeze of air passing over the subject. Alpha emission produces copious ions in the ambient air which are transported by the air current to an ion collector, resulting in a small electrical current proportional to the amount of contamination. Results indicate a conservative sensitivity of 3,000 disintegrations per minute localized to one of five areas of the body in a measurement lasting less than 2 minutes

  2. Hand and foot contamination monitor

    International Nuclear Information System (INIS)

    Jakati, R.K.; Kaptral, R.S.; Ananthkrishnan, T.S.; Pansare, M.G.

    1989-01-01

    In order to make quick measurements of beta and gamma contaminations on hands and feet of personnel working in radioactive environments, hand and foot contamination monitors are widely used. This paper describes such a monitor system designed with Intel 8085 based microcomputer. The monitoring and warning system is designed to perform measurement of activity spread over surface of hands and soles of shoes or feet. Even though the system has many features to aid testing and maintainance operation, it is easy to use for unskilled persons. In order to check the contamination, the person stands on platform and inserts both his hands into detector assemblies thereby actuating the sensing switches. After a preset interval, annunciation of clean or contaminated status is declared by the system. (author)

  3. 10 CFR 36.55 - Personnel monitoring.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Personnel monitoring. 36.55 Section 36.55 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR IRRADIATORS Operation of Irradiators § 36.55 Personnel monitoring. (a) Irradiator operators shall wear a personnel dosimeter that is...

  4. Monitoring of transport contamination

    International Nuclear Information System (INIS)

    Turkin, N.F.

    1980-01-01

    Organization of monitoring of transport contamination is considered. A particularly thorough monitoring is recommended to be carried out in loading-unloading operations. The monitoring is performed when leaving loading-unloading site and zone under control and prior to preventive examination, technical service or repair. The method of monitoring of auto transport contamination with high-energy β-emitters by means of a special stand permitting the automation of the monitoring process is described [ru

  5. 10 CFR 39.65 - Personnel monitoring.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Personnel monitoring. 39.65 Section 39.65 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY REQUIREMENTS FOR WELL LOGGING Radiation Safety Requirements § 39.65 Personnel monitoring. (a) The licensee may not permit an individual to act as a logging...

  6. 10 CFR 34.47 - Personnel monitoring.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Personnel monitoring. 34.47 Section 34.47 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Radiation Safety Requirements § 34.47 Personnel monitoring. (a) The licensee may not...

  7. Study of personnel monitoring programs

    International Nuclear Information System (INIS)

    Guerra, Aline B.; Lorenzini, Fabiane; Carlos, Janaina; Bernasiuk, Maria E.B.; Rizzatti, Mara R.; Fuentefria, Jose L.B.

    1996-01-01

    Surveillance of several health institutions who use ionizing radiation sources, as well as data from the state of Rio Grande do Sul (Brazil) are studied concerning the use of personnel dosimeters. The results show that several institutions do not provide them and those which provide do not know how to use them

  8. Personnel monitoring of radiations with thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Miano, S.C.

    1987-01-01

    The basics of personnel dosimetry technics, used by the Radiologic Protetion and Assessorie Service (SAPRA) are presented, consisting on use of thermoluminescent and CaSO 4 :Dy monitors in aggregated pellets by Teflon. The characteristics of this dosemeters, relating to the sensitivity, energetic dependence, spike temperature, characteristic emission curve, decay and light effect are shown. The thermoluminescent dosemeter measure system and the personnel monitoring system are also described. (C.G.C.) [pt

  9. Soil contamination standards for protection of personnel

    International Nuclear Information System (INIS)

    Rittmann, P.D.

    1998-01-01

    The objective of this report is to recommend soil contamination levels that will ensure that radionuclide intakes by unprotected workers are likely to give internal doses below selected dose limits during the working year. The three internal dose limits are 1, 100, and 500 mrem per year. In addition, photon, beta, and alpha instrument readings are estimated for these soil concentration limits. Two exposure pathways are considered: the first is inhalation of resuspended dust and the second is ingestion of trace amounts of soil. In addition, radioactive decay and ingrowth of progeny during the year of exposure is included. External dose from the soil contamination is not included because monitoring and control of external exposures is carried out independently from internal exposures, which are the focus of this report. The methods used are similar to those used by Carbaugh and Bihl (1993) to set bioassay criteria for such workers

  10. Soil contamination standards for protection of personnel

    Energy Technology Data Exchange (ETDEWEB)

    Rittmann, P.D.

    1998-04-16

    The objective of this report is to recommend soil contamination levels that will ensure that radionuclide intakes by unprotected workers are likely to give internal doses below selected dose limits during the working year. The three internal dose limits are 1, 100, and 500 mrem per year. In addition, photon, beta, and alpha instrument readings are estimated for these soil concentration limits. Two exposure pathways are considered: the first is inhalation of resuspended dust and the second is ingestion of trace amounts of soil. In addition, radioactive decay and ingrowth of progeny during the year of exposure is included. External dose from the soil contamination is not included because monitoring and control of external exposures is carried out independently from internal exposures, which are the focus of this report. The methods used are similar to those used by Carbaugh and Bihl (1993) to set bioassay criteria for such workers.

  11. Systematic approach to personnel neutron monitoring

    International Nuclear Information System (INIS)

    Griffith, R.V.; Hankins, D.E.

    1980-01-01

    NTA film and albedo detectors represent the major portion of personnel dosimeters now used for occupational neutron monitoring. However, recent attention to the spectral response of these systems has demonstrated the need for detectors that have a better match to the fields being monitored. Recent developments in direct recoil track etch dosimeters present some intriguing alternatives, and careful use of 237 Np fission fragment detectors offers the advantage of a good dose equivalent spectral match. Work continues on a number of other new detector mechanisms, but problems with sensitivity, energy response, gamma interference, etc., continue to prevent development of most mechanisms into viable personnel dosimeters. Current dosimeter limitations make a systematic approach to personnel neutron monitoring particularly important. Techniques have been developed and tested, using available portable survey instruments, that significantly improve the quality of dosimeter interpretation. Even simple spectrometry can be done with modest effort, significantly improving the health physicists ability to provide accurate neutron monitoring

  12. Automating the personnel dosimeter monitoring program

    International Nuclear Information System (INIS)

    Compston, M.W.

    1982-12-01

    The personnel dosimetry monitoring program at the Portsmouth uranium enrichment facility has been improved by using thermoluminescent dosimetry to monitor for ionizing radiation exposure, and by automating most of the operations and all of the associated information handling. A thermoluminescent dosimeter (TLD) card, worn by personnel inside security badges, stores the energy of ionizing radiation. The dosimeters are changed-out periodically and are loaded 150 cards at a time into an automated reader-processor. The resulting data is recorded and filed into a useful form by computer programming developed for this purpose

  13. Hand-held personnel and vehicle monitors

    International Nuclear Information System (INIS)

    Kunz, W.E.; Chambers, W.H.; Henry, C.N.; France, S.W.; Millegan, D.R.; Hastings, R.D.; Worth, G.M.

    1976-05-01

    A light, rugged monitor has been developed for special nuclear materials (SNM) searches at material-access and protection-area exits. This monitor accepts gamma-ray pulses from a NaI(Tl) detector, integrates for a preset counting interval (typically 0.3 s), and produces an audible alarm whenever the counts in the interval exceed the trip level that is a preset multiple of the stored background count. Because the monitor is silent except when the alarm is operating, personnel with little special training can conduct more effective searches in a noisy and distracting environment than they can with conventional audible monitoring of individual radiation counts. The monitor is also more sensitive than conventional monitors that provide audible indication of the count rate

  14. Basic requirements for personnel monitoring. 1980 ed

    International Nuclear Information System (INIS)

    1980-01-01

    This Code of Practice sets forth the objectives of an adequate system of personnel monitoring for radiation workers. It covers individual dosimetry, including internal radiation monitoring, and area monitoring to the extent required for the assessment of individual radiation doses. The responsibilities of authorities for organizing monitoring of radiation workers are discussed, together with brief descriptions of monitoring methods and the rules governing their application. The general principles to be considered in selecting instrumentation and the appropriate monitoring techniques are described, as well as calibration techniques, methods of data handling and record keeping. Current concepts and recommendations of the International Commission on Radiological Protection, as presented in ICRP Publication No.26, have been incorporated. New developments in techniques and instruments have been reflected, and several sections such as calibration and record keeping have been elaborated. The bibliography has been updated and new annexes added.

  15. Unregulated Contaminant Monitoring Program Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — EPA uses the Unregulated Contaminant Monitoring (UCM) program to collect data for contaminants suspected to be present in drinking water, but that do not have...

  16. Radiation monitoring data representation for duty personnel

    Energy Technology Data Exchange (ETDEWEB)

    Gavrilov, S.L.; Kiselev, V.P.; Krasnoperov, S.N.; Kudeshov, E.V.; Maslov, S.Y.; Semin, N.N.; Sirotinskiy, S.E.; Yakovlev, V.Y. [Nuclear Safety Institute of the Russian Academy of Sciences (NSI RAS), Moscow (Russian Federation)

    2014-07-01

    Currently, Web-GIS technologies are widely used to generate a reliable and intuitive web-based interface to monitor the current radiation situation in various regions of the Russian Federation. The developed 'Server Web-Monitoring' web-application is intended for duty personnel and can operate not only on desktop computers but also on mobile devices. The subsystem of duty personnel notification about any Off-Normal Situation (ONS) (such as: critical threshold exceedances or failures in operation of monitoring systems) is also considered in the paper. Three types of Automated Radiation Monitoring Systems (ARMS) are available for monitoring: - regional ARMS; - facility-level ARMS; - ARMS of nuclear power plant surveillance areas. Google Maps and Google Maps API toolbox are used as the cartographic basis. In the general-monitoring window only general information on each of the local systems is available. Next, the operator can move to monitoring of local ARMS he is interested in. The operator can either view a list of Radiation Situation Monitoring Posts (RSMP) showing the current data in the right frame or hide it and use the map only. Viewing the log of critical threshold exceedances for 24 hours and a report on all RSMPs of a given system over the last 7 days is also possible. The report contains maximum values of measurements for every day and for each RSMP. The developed web-application includes: - monitoring of the radiation situation and its changes on the general map of the Russian Federation and on maps of local ARMS; - displaying 7-day reports for all RSMPs of the selected ARMS; - displaying the log of critical threshold exceedances recorded over the past day. The notification subsystem informs duty personnel on all ONS, namely, on critical threshold exceedances in the incoming data and failures in operation of monitoring systems. The key features of the notification subsystem are: - round-the-clock functioning; - automatic notification in case of

  17. The design of hands and feet contamination monitor

    International Nuclear Information System (INIS)

    Song Jiangxue; Shen Yang; Deng Changming; Zhang Jia; Hou Lei; Meng Dan

    2011-01-01

    In order to protect the hands and feet of personnel engaged in nuclear, draw on advanced hands and feet contamination monitor, we design a new radiation protection instrumentation. It describes the composition of the hands and feet contamination monitor, and software program design. It describes the hardware monitor software, firmware and computer programming techniques. If device found your hand and foot surface is contamination, it will prompt you to decontamination, to protect your hands and feet of safety. (authors)

  18. Contamination monitoring activities in Kanupp

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, S S [Karachi Nuclear Power Plant (Pakistan)

    1997-06-01

    The Karachi Nuclear Power Plant (Kanupp) is a 137 MWe pressurized heavy water reactor, designed and erected by the Canadian General Electric Company as a turn key project. The plant is in operation since it was commissioned in the year 1972. It is located at the Arabian Sea Coast about 15 miles to the west of Karachi. During its more than two decades of operation, the plant has generated about 8 billion units of electricity with an average life time availability factor of 60%. In Kanupp, radioactive contamination may exit due to the release of fission product, activation products etc., which may somehow escape from its confinement and may contaminate surface or other media such as air, water etc. In this paper, following items are described: main aspects of contamination, status of contamination monitoring, need of contamination monitoring, radiation protection activity, instruments, contamination, current status of contamination survey materials and their disposal, and environmental monitoring. (G.K.)

  19. Background compensation methodologies for contamination monitoring systems

    International Nuclear Information System (INIS)

    Raman, Anand; Chaudhury, Probal; Pradeepkumar, K.S.

    2014-01-01

    Radiation surveillance program in the various nuclear facilities incorporate contamination monitoring as an important component. Contamination monitoring programs constitute monitoring for alpha and beta contamination of the physical entities associated with the working personnel that include his hands, feet, clothing, shoes as well as the general surface areas in the working environment like floors. All these measurements are fraught with the contribution of the ambient gamma background radiation fields. These inhibit a proper and precise estimation of the contamination concentration being monitored. This paper investigates the efficacy of two methodologies that have been incorporated in two of the contamination monitoring systems developed in the Division. In the first system discussed, a high degree of gamma compensation has been achieved for an uniform exposure of the order of 50 nSv/hr to 100 mSv/hr. In the second system discussed, the degree of gamma compensation achieved is equal to those dictated by the statistical nature of the uncertainties associated with the subtraction of background from the source data. These two methods can be very effectively employed depending on the application requirement. A minimum detection level equivalent to 0.37 Bq/cdm 2 has been achieved in both these cases

  20. Experience of TLD personnel monitoring laboratory

    International Nuclear Information System (INIS)

    Jakhete, Prashant

    2002-01-01

    Full text: Renentech Laboratories is the first Private Enterprise in India to have been chosen to provide Personnel radiation monitoring services to radiation workers at different parts of the country. Since 1992 the Company has been manufacturing TLD phosphor powder of requisite quality and from 1995 commenced the production of TLD cards for radiation monitoring. After getting the necessary approval from the competent authorities in the country, the company undertook a rigorous quality assurance programme and received the accreditation in 1999 to carry out the personnel monitoring of radiation. Since then the trained staff of the Company is covering 1200 institutions in 16 states where radiation is being used. This translates to processing of 60,000 Till cards annually, the maximum limit permitted by BARC. Processing of exposure data is done strictly according well-laid guidelines. Any cases of overexposure are immediately referred to Calibration and Dose Record Section of BARC to meet the regulatory requirements. Necessary procedural guidelines are followed to handle such cases. In this lecture, learning, operation and implementation experience of a typical Private Company in a task, which, hitherto had been regarded as exclusive responsibility of state owned institution, is enumerated

  1. Personnel monitoring system by thermoluminescence dosimeter - a study and review

    International Nuclear Information System (INIS)

    Iyer, V.S.; Alok, M.; Chandel, B.S.

    2018-01-01

    The principle objective of personnel monitoring system is to prevent overexposure and avoid unnecessary exposure of personnel working with various sources of radiation. The adequate system of personnel monitoring must provide for the measurement. evaluation and recording of significant doses accumulated by individuals together with a recording of conditions under which these doses are received

  2. Selected references on thermoluminescent dosemeters for personnel monitoring

    International Nuclear Information System (INIS)

    Lawson, Helen

    1976-08-01

    This bibliography contains references on: specific thermoluminescent dosemeters used for personnel dosimetry; comparisons of thermoluminescent and other dosemeters for personnel monitoring and read-out apparatus for thermoluminescent dosemeters. An appendix contains selected foreign language references. (author)

  3. Personnel radiation exposure in the Asse saltmine repository during 1967 to 2008. Health monitoring Asse

    International Nuclear Information System (INIS)

    2011-02-01

    The health monitoring Asse includes the following chapters: Introduction, background information including handling of radioactive materials and radiation protection issues, data on radiation exposure (personnel dosimetry, incorporation surveillance, local dose rate measurements, exhaust monitoring, radioactivity in the salt mine air and in the brine, contamination), concept of the data base, interrogation of the personnel, quantification of the individual radiation doses, results of the radiation exposure quantification; significance of the results and perspectives.

  4. The Basic Requirements for Personnel Monitoring

    International Nuclear Information System (INIS)

    1965-01-01

    The code of practice presented here as part of the Agency's Safety Standards deals with the problem of personnel monitoring in establishments in which, or in part of which, work is primarily with radiation sources. It is a development of the fundamental requirements on the subject contained in the Agency's Basic Safety Standards. The code has been prepared by the Secretariat of the Agency on the basis of the work of a panel of experts drawn from a number of Member States. In addition, representatives of several interested international organizations participated in the work of the panel. The Board of Governors of the Agency considered this code of practice in September 1964 and authorized its application to Agency and Agency-assisted operations and recommended to Member States that it be taken into account in the formulation of national regulations or recommendations.

  5. Analysis of personnel monitoring control card data

    International Nuclear Information System (INIS)

    Ande, C.D.; Sneha, C.; Madhumita, B.; Bakshi, A.K.; Datta, D.

    2018-01-01

    In India, personnel monitoring of radiation workers for X-, beta- and gamma- radiation is carried out using a thermoluminescence dosemeter (TLD) system based on CaSO 4 :Dy Teflon TLD disc. A large number of radiation workers get very low occupational doses and their doses are reported as zero since it is not above detectable limits. Therefore, the detection of low levels of occupational dose over and above the natural background assumes great importance. In the present system, the estimation of the background dose is achieved by use of control dosemeters. An analysis of the readings of the control dosimeters sent to various institutions was carried out to arrive at conclusions regarding the validity of the use of control dosimeter

  6. A new type of spurious reading in TL personnel monitoring

    International Nuclear Information System (INIS)

    Duftschmid, K.E.; Stadtmann, H.; Strachotinsky, Ch.; Winker, N.

    1996-01-01

    A particularly serious type of spurious reading in automated TL personnel monitoring has been observed. These readings simulate dose values up to several mSv and can only be detected by glow curve analysis. Characteristics for these events are high artifical dose values and irregular glow curves of a particular shape. Extensive investigations to reproduce this effect purposely failed to produce any results. It can be assumed, however, that it must be some chemical surface contamination, which penetrates the sealed dosemeter bag or which is transferred from the bag to the detector. The effect can be eliminated by manual cleaning of the dosemeter cards. The importance of this observation lies in the fact that only proper glow curve evaluation can prevent the monitoring service from reporting artificial high dose readings creating lots of serious problems. The paper shows how this problem can be avoided for this kind of spurious effect, if glow curves are available and stored for every dosemeter readout. (author)

  7. Motivational Monitoring as a Tool of Managing Fluctuation of Personnel

    OpenAIRE

    Darchenko Nataliya D.

    2013-01-01

    The goal of the article lies in the study of a possibility to manage fluctuation of personnel at a modern enterprise through application of the motivational monitoring and in identification of some methodical aspects of formation of the system of monitoring the fluctuation of personnel. The article considers the essence, tasks and main directions of motivational monitoring at an enterprise and offers its classification. It proves urgency of the problem of fluctuation of personnel at enterpris...

  8. Personnel Neutron Monitoring at AB Atomenergi

    Energy Technology Data Exchange (ETDEWEB)

    Hagsgaard, S; Widell, C O

    1964-02-15

    The routine personnel monitoring of fast neutrons is carried out by the counting of tracks in a nuclear emulsion. The tracks are counted in a microscope on a projection screen. This is a very tedious job and is only done on irradiated films which are counted over 6 mm{sup 2}. The irradiated films are selected according to the recorded dose on the gamma film. It is often difficult to tell how much the visible tracks have faded during a two-weeks period. Fortunately the fading does not often exceed 20 % for this period. If the dosimeter has been gamma-irradiated, it may be difficult to recognize the proton tracks. If the film is stored for some time before being developed, this gamma fog will to some extent fade away. For large neutron doses a foil activation dosimeter is used. This dosimeter consists of a cadmium-shielded phosphorus foil, a cadmium shielded gold foil and an unshielded gold foil. The phosphorus foil has to be counted shortly after exposure.

  9. Personnel Neutron Monitoring at AB Atomenergi

    International Nuclear Information System (INIS)

    Hagsgaard, S.; Widell, C.O.

    1964-02-01

    The routine personnel monitoring of fast neutrons is carried out by the counting of tracks in a nuclear emulsion. The tracks are counted in a microscope on a projection screen. This is a very tedious job and is only done on irradiated films which are counted over 6 mm 2 . The irradiated films are selected according to the recorded dose on the gamma film. It is often difficult to tell how much the visible tracks have faded during a two-weeks period. Fortunately the fading does not often exceed 20 % for this period. If the dosimeter has been gamma-irradiated, it may be difficult to recognize the proton tracks. If the film is stored for some time before being developed, this gamma fog will to some extent fade away. For large neutron doses a foil activation dosimeter is used. This dosimeter consists of a cadmium-shielded phosphorus foil, a cadmium shielded gold foil and an unshielded gold foil. The phosphorus foil has to be counted shortly after exposure

  10. Basic requirements to the methods of personnel monitoring

    International Nuclear Information System (INIS)

    Keirim-Markus, I.B.

    1981-01-01

    Requirements to methods of personnel monitoring (PMM) depending on irradiation conditions are given. The irradiation conditions determine subjected to monitoring types of irradiation, measurement ranges, periodicity of monitoring, operativeness of obtaining results and required accuracy. The PMM based on the photographic effect of ionizing radiation is the main method of the mass monitoring [ru

  11. NSF-RANN Trace Contaminants Program directory. [Personnel directory

    Energy Technology Data Exchange (ETDEWEB)

    Purnell, P.A.; Smith, S.K.; Wilkes, C.F.

    1976-10-01

    This directory is designed to aid effective communication throughout the National Science Foundation's Trace Contaminants Program, Research Applied to National Needs. The majority of the participants in the Program are represented by name, address, telephone number, and a very brief description of research interest. The directory has five major divisions to facilitate its use. Section I contains a listing of the program managers associated with the NSF-RANN Trace Contaminants Program. Section II lists the principal investigators, co-principal investigators, and coordinators of each of the research grants in the Program. Section III lists the personnel by individual projects. Section IV contains a total alphabetic listing complete with project titles and Section V contains a keyword index. This directory is maintained by the Toxic Materials Information Center as part of the Environmental Resource Center of the Information Center Complex, Information Division, Oak Ridge National Laboratory.

  12. Personnel radiation monitoring by thermoluminescence dosimetry (2000-2001)

    International Nuclear Information System (INIS)

    Mi-Cho-Cho, Daw; Hla-Hla-Win, Daw; Thin-Thin-Kraing

    2001-01-01

    Thermoluminescence dosimetry service was introduced in 1991. Personnel who exposed directly or indirectly to radiation is monitored by thermoluminescent dosimeter. TL materials used for thermoluminescent dosimeter are in the form of thin disc. Personnel whole-body and extremity doses are measured by thermoluminescence dosimetry. The Harshaw Model 4500 TLD reader and Vinten 654E TLD reader are used for TLD evaluation. At present about 600 radiation workers are provided with TLD for routine monitoring. It was found that most personnel had received within permissible dose recommended by the International Commission on Radiological Protection (ICRP). (author)

  13. Organization of internal contamination monitoring

    International Nuclear Information System (INIS)

    Badreddine, A.

    1986-07-01

    The nuclear energy takes a big part in the world's energy production. The nuclear techniques are used in most fields of life. Nevertheless the use of radioactive materials may cause prejudice to human beings by radiation contamination. The International Commission on Radiological Protection gives the general rules and regulations to avoid this danger. In the publication No. 30, the ICRP gives a metabolic model for the respiratory system and values of Annual Limit of Intake. The ALI for inhalation supposes a standard AMAD (Activity Median Aerodynamic Diameter) of 1 um. We have measured the AMAD in a laboratory under different conditions of functioning in order to show its variation. Then we have analysed the effect of this variation on the internal contamination monitoring. Thus we have calculated the Effective Committed Dose (ECD), the ALI, then the Derived Investigation Level (DIL) for different values of AMAD for Whole-Body Counting (WBC)

  14. A systematic approach to personnel neutron monitoring

    International Nuclear Information System (INIS)

    Griffith, R.V.; Hankins, D.E.

    1980-01-01

    In selection, calibration and interpretation of personnel neutron dosimeters used in radiation protection, adequate attention is often not given to matching the characteristics of the dosimeter with the quality of the neutron field. A particular concern is the use of albedo detectors which have little energy response similarity to the neutron dose equivalent conversion curve. At the Lawrence Livermore Laboratory we have developed a system for dosimeter calibration and neutron field characterization using Bonner spheres and remmeters. Rapid surveys of the work area with detectors in 3-in and 9-in polyethylene spheres establish a qualitative estimate of spectral variation found in the facility. We also use this data to determine the appropriate albedo dosimeter calibration factors. At several locations representing the spectral range, multisphere spectra measure-ments are made and the spectrum weighted dose equivalent rates calculated. These rates are compared with survey instrument results to establish correction factors for the relative over- or under-response expected from these instruments, particularly in highly moderated neutron fields where remmeters overrespond. We also use the spectral information to determine the appropriateness of dosimeters considered for future use. This technique has been applied at power reactors to provide information valuable to selection of proper personnel dosimeters. We find that the spectral range is sufficiently narrow that albedo detectors can be used with confidence. On the other hand, most of the dose occurs at energies below the effective threshold NTA film. (author)

  15. Calibration of instrument and personnel monitoring in radiological protection

    International Nuclear Information System (INIS)

    Abdul Aziz Mohamad Ramli; Wan Saffiey Wan Abdullah

    1987-01-01

    It is difficult to choose radioprotection equipments that are not too expensive and suit the purpose. Some of the dosimetric characteristics of good dosemeters outlined by ISO 4071-1978 (E) namely scale linearity, energy dependence, radiation quality dependence and angular dependence for some of the commercially available dosemeters are discussed. The calibration procedures practised at the National Secondary Standard Dosimetry Laboratory (SSDL), of the Nuclear Energy Unit (NEU) is also explained. The radiological equipments for personnel monitoring such as film badge and TLD are widely used to estimate the radiation dose delivered to the whole or partial body of a personnel. Both of the personnel monitoring procedures have been established at the NEU. The objective, use and maintenance of the devices are also discussed in detail. The evaluation of the monthly dose received by a personnel from various establishments in the country are also presented. (author). 17 figs

  16. Country report on contamination monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Oyuntulkhuur, Navaangalsan [National Centre for Hygiene, Epidemiology and Microbiology (Mongolia). Central Radiological Laboratory

    1997-06-01

    Mongolia is a non-nuclear country and has currently neither nuclear power plants nor research reactors. This country joined the Regional Co-operation Agreement (RCA) for the Asia Pacific region for research, development and training related to nuclear science and technology in 1993. Various measures has been taken for strengthening of radiation protection, cooperated with several international organizations mainly with IAEA. In Mongolia radioactive substances and sources are used for the following purposes: for research work; medical radiotherapy and diagnostic radiology in hospitals; industrial enterprises for technological processes; and for non-destructive testing in industry. Radiation safety inspection is conducted by the CRL. The inspections consist of verification of compliance with radiation safety requirements and with any additional requirements specified in the authorization of accounting records and a physical check on the presence of radiation sources; check on the work carried out by the radiation safety services to monitor radioactive contamination of the environment; and measurements and sampling. CRL should take much attention for improvement and development of the activities in the field of surface contamination monitoring concerning a wide use of radionuclides in different field of economy. (G.K.)

  17. Development and radiation evaluation of mobile station for personnel monitoring system based on indigenous plastic scintillator sensor rods

    International Nuclear Information System (INIS)

    Chaudhary, H.S.; Parihar, A.; Senwar, K.R.; Prakash, V.; Rathore, A.S.

    2018-01-01

    The Mobile Station for Personnel Monitoring (MSPM) system has been designed and developed for rapid screening of personnel with respect to radiation contamination during nuclear or radiological emergency; it can also be used for prevention of illicit movement of radioactive sources. The objective was to develop a modular, transportable and easily deployable gamma portal monitoring system based on indigenous DLJ developed plastic scintillator sensors. The Gamma radiation response of the system is presented here

  18. The use of film badges for personnel monitoring

    International Nuclear Information System (INIS)

    Ehrlich, M.

    1962-01-01

    Photographic film is fairly inexpensive and durable and as a result of irradiation its radiosensitive components undergo relatively permanent changes. With proper calibration the optical density of the development and fixed photographic film can be related to radiation exposure. Personnel monitoring with photographic film is the method of choice in many laboratories, and this manual gives guidelines for the use of photographic film in personnel dosimetry.

  19. Radiation detectors for personnel monitoring - current developments and future trends

    International Nuclear Information System (INIS)

    Kannan, S.

    2003-01-01

    The radiation detectors for personnel monitoring range from the conventional passive dosimeters like the film badge and the TLD, to sophisticated active dosimeters for integrated gamma, beta and neutron dose measurement. With the availability of high accuracy active dosimeters, the process of personnel monitoring, acceptability among radiation workers, record keeping and dose control have become more simplified. However the high level of sophistication in the active dosimeter has its own inevitable price tag and the new breed of active dosimeters are prohibitively costly. The silver lining, in the otherwise dark cost scenario of these dosimeters is the potential for cost reduction at least in some of the dosimeters in the near future

  20. Status on contamination monitoring in China

    Energy Technology Data Exchange (ETDEWEB)

    Quanlu, Gou [China Institute for Radiation Protection, Taiyuan (China)

    1997-06-01

    The air contaminated by radioactive materials in nuclear enterprises and radioactive workplaces and forming radioactive aerosol and the leakage of radioactive materials in operation cause internal exposure damage in workers. It is necessary and important to monitor air and surface contaminations for the health of public and workers, and for protecting environment. At present, many institutes engage in the studies on surface contamination monitoring in China, and the government has formulated the control limits of surface contamination in the Regulations of Radiation Protection. The monitors for surface contamination monitoring are almost home-made. The methods being used often are smear test and placing surface sample test. Scintillation counters, semiconductor detectors and G-M counters have been used for detecting alpha surface contamination. Plastic scintillator meters and thin wall/window G-M counters are used for beta surface contamination. Special detectors have been designed for monitoring low energy nuclides. The status of airborne contamination monitoring in China is reported. As the studies for future, the development of the surface contamination monitor for low energy beta nuclides, especially H-3, the monitoring methods for the special shapes of surfaces, the technology of decontamination and the calibration method and device for on-line radioactive aerosol continuous monitors are taken up. (K.I.)

  1. A new development in personnel monitoring

    International Nuclear Information System (INIS)

    Fletcher, R.J.

    1993-01-01

    For several years the UK National Radiological Protection Board (NRPB) has felt that the next major development in personal dosimetry should be an electronic dosemeter which would read out directly, to improve control of exposures and achieve a reduction in individual doses. This became a possibility when an arrangement of solid-state detectors and filters was developed at the NRPB which was suitable for the measurement of the individual photon dose equivalent. Since then, further development has taken place at the NRPB for the measurement of the individual dose equivalent superficial for β-radiation. The measurements are made in the quantities Hp(10) and Hs(0.07), as recommended by the ICRU for individual monitoring. Thus, the basic detector system for the development of an electronic dosemeter has been established. The device is now being manufactured and marketed. An electronic personal dosimetry service is described, together with the procedure which is being adopted to gain approval in the UK for monitoring the exposure of classified workers. The NRPB considers this to be the next logical development in personal dosimetry, and it has been shown that the device offers a number of advantages for this purpose. (Author)

  2. Development of remote operated floor contamination monitor

    International Nuclear Information System (INIS)

    Sreekumar, K.; Gangamohan, M.; Kannan, R.K.; Rajan, S.

    2005-01-01

    Contamination check of floors and walkways in and around Reactor building areas forms an integral part of Radiation Protection Program in Power Stations. Though random swipe check method is adopted for the detection of loose contamination, this method has the disadvantage of leaving the fixed contamination and hotspots undetected. Hence, scanning the area with a sensitive detector, held close to the surface provides positive means for the detection of contamination. Checking large areas and walkways by holding the detector close to the surface involves physical work. Also, areas which are unapproachable due to congestion of equipment, may go uncovered by contamination monitoring in order to eliminate the physical strain involved in such contamination monitoring and to cover unapproachable areas, a small size prototype device that can be operated remotely was fabricated. This device detects contamination instantaneously and accurately. This paper describes design and fabrication of the device used for floor contamination monitoring. (author)

  3. Storage of radioactive material - accidents - precipitation - personnel monitoring

    International Nuclear Information System (INIS)

    Matijasic, A.; Gacinovic, O.

    1961-12-01

    This volume covers the reports on four routine tasks concerned with safe handling of radioactive material and influence of nuclear facilities on the environment. The tasks performed were as follows: Storage of solid and liquid radioactive material; actions in case of accidents; radiation monitoring of the fallout, water and ground; personnel dosimetry

  4. Implementation of quality control systematics for personnel monitoring services

    International Nuclear Information System (INIS)

    Franco, J.O.A.

    1984-01-01

    The implementation of statistical quality control techniques used in industrial practise is proposed to dosimetric services. 'Control charts' and 'sampling inspection' are adapted respectively for control of measuring process and of dose results produced in routine. A chapter on Radiation Protection and Personnel Monitoring was included. (M.A.C.) [pt

  5. Monitoring of surface and airborne contamination

    Energy Technology Data Exchange (ETDEWEB)

    Pradeep Kumar, K S [Bhabha Atomic Research Centre, Bombay (India)

    1997-06-01

    Indian nuclear energy programme aims at total safety in all activities involved in the entire fuel cycle for the occupational workers, members of the public and the environment as a whole. Routine radiation monitoring with clearly laid out procedures are followed for ensuring the safety of workers and public. Radiation monitoring carried out for the nuclear installations comprises of process monitoring, monitoring of effluent releases and also of the radiation protection monitoring of the individuals, work place and environment. Regulations like banning of smoking and consumption of food and drink etc. reduces the risk of direct ingestion even if inadvertent spread of contamination takes place. Though limit of transportable surface contamination is prescribed, the health physicists always follow a ``clean on swipe`` philosophy which compensates any error in the measurement of surface contamination. In this paper, the following items are contained: Necessity of contamination monitoring, accuracy required in the calibration of surface contamination monitors, methodology for contamination monitoring, air monitoring, guidelines for unrestricted release of scrap materials, and problems in contamination monitoring. (G.K.)

  6. Monitoring of plutonium contaminated solid waste streams

    International Nuclear Information System (INIS)

    Birkhoff, G.; Notea, A.

    1977-01-01

    The planning of a system for monitoring Pu contaminated solid waste streams, from the nuclear fuel cycle, is considered on the basis of given facility waste management program. The inter relations between the monitoring system and the waste management objectives are stressed. Selection criteria with pertinent data of available waste monitors are given. Example of monitoring systems planning are presented and discussed

  7. Microbial contamination level profiles attributed to contamination of beef carcasses, personnel, and equipment: case of small and medium enterprise slaughterhouses

    DEFF Research Database (Denmark)

    Wambui, Joseph; Lamuka, Peter; Karuri, Edward

    2018-01-01

    The microbial contamination level profiles (MCLPs) attributed to contamination of beef carcasses, personnel, and equipment in five Kenyan small and medium enterprise slaughterhouses were determined. Aerobic plate counts, Enterobacteriaceae, Staphylococcus, and Salmonella were used to determine...... contamination at four different slaughter stages, namely, dehiding, evisceration, splitting, and dispatch. Microbiological criteria of the four microorganisms were used to score contamination levels (CLs) as poor (0), poor to average (1), average (2), or good (3). MCLPs were further assigned to carcasses......, personnel, and equipment at each stage by summing up the CL scores. The CL score attributed to aerobic plate count contamination was 2 or 3 for carcasses but 0 for personnel and equipment in almost all slaughterhouses. A score of 0 on carcasses was mostly attributed to Enterobacteriaceae at evisceration...

  8. Monitoring of the internal contamination of occupationally exposure personnel in services of nuclear medicine through the use of gamma cameras; Monitoreo de la contaminacion interna de personal ocupacionalmente expuesto en servicios de medicina nuclear mediante el uso de gamma camaras

    Energy Technology Data Exchange (ETDEWEB)

    Teran, M.; Paolino, A.; Savio, E. [Catedra de Radioquimica, Facultad de Quimica, Montevideo (Uruguay); Hermida, J.C. [Centro de Medicina Nuclear, Hospital de Clinicas, Facultad de Medicina, Montevideo (Uruguay); Dantas, B.M. [Laboratorio de Medidas In vivo, Instituto da Radioprotecao e Dosimetria, Rio de Janeiro (Brazil)

    2006-07-01

    The radionuclides incorporation can happen as a result of diverse activities; these include the work associated with the different stadiums of the nuclear fuel cycle, the use of radioactive sources in medicine, the scientific research, the agriculture and the industry. In Uruguay the main activities linked to the manipulation of open sources correspond those of Nuclear Medicine and from 2004, in the mark of the Project Arcal RLA 049 and being based on the Safety Guides of the IAEA it is implementing a program of internal monitoring in combined form the Nuclear Medicine Center of the Hospital of and the Radiochemistry class of the Faculty of Chemistry. In accordance with the publication of the ICRP 75 the emphasis of any monitoring program should be in the formal study of the doses in the workers to who are considered commendable of to receive in routine form an outstanding fraction of the dose limits or who work in areas where the exposures can be significant in the accident event. From April 2004, to the date has started a pilot plan by means of in that were established appropriate conditions of procedures and of safety in a reduced group of workers of the Nuclear Medicine area. In that period the first work limits, equipment adjustment, calibrations and registration systems were determined. The monitoring system implemented until the moment is carried out with a thyroid caption equipment. However these measurements are carried out in the university hospital embracing 40% of the involved workers of our country, with the purpose of reaching the covering of the biggest quantity of occupationally exposed personnel of private clinics. Also it was developed a new work proposal that allows to have an alternative measure method, in the event of not having the equipment habitually used. Among the conclusions of this work are that for the before exposed are considered the measure conditions but appropriate the following ones: Gamma Camera without collimator; Measurement

  9. Development of radioactive surface contamination monitor

    International Nuclear Information System (INIS)

    Hashimoto, Tadao; Hasegawa, Toru; Fukumoto, Keisuke; Ooki, Yasushi

    2008-01-01

    In the radiation facilities such as nuclear power plants, surface contamination of the people accessing or articles conveyed in and out of the radiation controlled areas is detected and monitored by installing contamination monitors at the boundary of controlled areas and uncontrolled areas against the expansion of the radioactive materials to out of the facilities. It is required for the surface contamination of articles to be tightened of control criteria as 'Guidelines for discrimination ways of nonradioactive waste (not classified as radioactive waste) generated from nuclear power plants' (hereinafter referred to as 'the Guideline') was established by the Nuclear and Industrial Safety Agency of the Ministry of Economy, Trade and Industry in August, 2005. It predicts that the control criteria of monitors other than article monitors are also tightened in the future. Fuji electric has been fabricating and delivering surface contamination detecting monitors. Now we are developing the new contamination monitor corresponding to the tightening of the control criteria. 'Large article transfer monitor', 'Clothing monitor' and 'Body surface contamination monitor' are introduced in this article. (author)

  10. Current status of personnel monitoring for β particles

    International Nuclear Information System (INIS)

    Plato, P.; Miklos, J.

    1984-01-01

    From 1975 to 1982, a concerted effort was made to develop a uniform procedure to test the performance of personnel dosimetry processors throughout the United States. The heart of this effort is a standard developed by the Health Physics Society Standards Committee (HPSSC) and adopted by the American National Standards Institute (ANSI) as ANSI N13.11-1982. The US Nuclear Regulatory Commission (NRC) sponsored a five year pilot study of this Standard which included three trial tests in which approximately 80 dosimetry processors participated. This paper addresses two major questions. First, what have the HPSSC/ANSI Standard and the NRC-sponsored pilot study contributed toward improvements in personnel monitoring for β particles. Second, what additional improvements are necessary. The Standard defines test categories for β particles and mixtures of β particles plus γ rays in addition to test categories for other types of radiation. It also defines a reference β-particle source for test purposes. Third, it provides test criteria which are used to determine acceptable performance by a processor. The pilot study provided information on the state of the art of personnel monitoring within the bounds of the Standard. In addition, since the pilot study was advertised as the forerunner of a future mandatory certification program for dosimetry processors throughout the United States, considerable attention was given to personnel monitoring in general, and β particles in particular, that otherwise would have been given to other squeaky wheels. The results of the three tests of the pilot study are summarized. The paper also amplifies on the needs to define the monitoring problems of the work place and to define appropriate β-particle sources clearly

  11. Current status of personnel monitoring for beta particles

    International Nuclear Information System (INIS)

    Plato, P.; Miklos, J.

    1983-01-01

    From 1975 to 1982, a concerted effort was made to develop a uniform procedure to test the performance of personnel dosimetry processors throughout the United States. The heart of this effort is a standard developed by the Health Physics Society Standards Committee (HPSSC) and adopted by the American National Standards Institute (ANSI) as ANSI N13.11-1982. The US Nuclear Regulatory Commission (NRC) sponsored a five year pilot study of this Standard which included three trial tests in which approximately 80 dosimetry processors participated. The Standard has made several contributions to the art and science of personnel monitoring for beta particles. First, the Standard defines test categories for beta particles and mixtures of beta particles plus gamma rays in addition to test categories for other types of radiation. Second, it defines a reference beta-particle source for test purposes. Third, it provides test criteria which are used to determine acceptable performance by a processor. The pilot study provided information on the state of the art of personnel monitoring within the bounds of the Standard. In addition, since the pilot study was advertised as the forerunner of a future mandatory certification program for dosimetry processors throughout the United States, considerable attention was given to personnel monitoring in general, and beta particles in particular. This paper discusses specific contibutions of the HPSSC/ANSI Standard and the pilot study to beta-particle dosimetry. The results of the three tests of the pilot study are summarized. The paper also amplifies on the needs to define the monitoring particle sources clearly

  12. Maintenance experiences with hand and foot monitor for monitoring alpha and beta radiation of personnel in NFC

    International Nuclear Information System (INIS)

    Ramachandra Rao, A.; Kulkarni, R.S.; Banerjee, P.K.

    2010-01-01

    NFC is producing natural uranium and enriched uranium fuels for various reactors including PHWR etc. Monitoring of α and β radiations in the active plants of NFC is very much essential in many aspects. The personnel who are handling radiation materials have to be monitored for α radiation of hands and cloths and β radiation of feet. So the Alpha and Beta Monitor became important monitoring equipment for monitoring α and β radiations of persons working in active plants of NFC. Many Alpha and Beta Monitors of make, ECIL, PLA, and Nucleonix etc. were being used in active plants in NFC. Basically α and β radiation monitors consists of four PMT (Photo Multiplier Tubes) for detection of radiation of hands and one PMT for monitoring clothes. The PMT use ZnS (Ag) as the scintillator for detection of α radiation. GM tubes are used to detect β radiation of feet. The latest Hand and Foot Monitors have been incorporated with PC based monitoring system along with software for making the monitoring process more efficient and user friendly. As an instrumentation maintenance team for these monitors, our experiences are varied. These monitors are to be periodically maintained and tested for its effective functioning in monitoring the nuclear radiation. The monitors procured from M/s. ECIL were being used since long time in these areas. The instrumentation maintenance had faced some problems with these monitors such as frequent failure of High Voltage cards, Amplifier and Counter PCB cards. Modifications were made in the circuits of High Voltage and Counter cards to minimize the failure rate and for loading of Display and Monitoring Software through Hard disk instead of from floppy disk. So the availability of monitors for monitoring radiation got improved. Later the introduction of more sophisticated α and β radiation monitors of M/s. PLA make in these areas further improved monitoring of radiation of personnel working in active areas. These monitors are more user

  13. Contamination monitoring: an overview and its objectives

    International Nuclear Information System (INIS)

    Mangena, S.

    2013-04-01

    The study presents and objectively summarises the aspect of contamination monitoring. This envisages reviewing sources of contamination and evaluating the scientific basis for practice specific courses of action for rehabilitation in a bid to restore pristine conditions wherever possible. The practices considered include nuclear medicine, reprocessing plants, fuel production plants, uranium and thorium mining and milling together with near surface disposal facilities (for radioactive waste). It also deals with monitoring sites contaminated as a consequence of past practices. General issues related to the design and operation of monitoring systems during and in the aftermath of a nuclear or radiological accident are also discussed including monitoring for long lived radionuclides widely dispersed in the environment following an accidental release. Thus the above discourse provides a framework for both quantitative and qualitative measures undertaken to enable effective response in the event of radioactive contamination. (au)

  14. Calibration of alpha surface contamination monitor

    International Nuclear Information System (INIS)

    Freitas, I.S.M. de; Goncalez, O.L.

    1990-01-01

    In this work, the results, as well as the methodology, of the calibration of an alpha surface contamination monitor are presented. The calibration factors are obtained by least-squares fitting with effective variance. (author)

  15. Microbial Contamination Level Profiles Attributed to Contamination of Beef Carcasses, Personnel, and Equipment: Case of Small and Medium Enterprise Slaughterhouses.

    Science.gov (United States)

    Wambui, Joseph; Lamuka, Peter; Karuri, Edward; Matofari, Joseph; Njage, Patrick Murigu Kamau

    2018-04-01

    The microbial contamination level profiles (MCLPs) attributed to contamination of beef carcasses, personnel, and equipment in five Kenyan small and medium enterprise slaughterhouses were determined. Aerobic plate counts, Enterobacteriaceae, Staphylococcus, and Salmonella were used to determine contamination at four different slaughter stages, namely, dehiding, evisceration, splitting, and dispatch. Microbiological criteria of the four microorganisms were used to score contamination levels (CLs) as poor (0), poor to average (1), average (2), or good (3). MCLPs were further assigned to carcasses, personnel, and equipment at each stage by summing up the CL scores. The CL score attributed to aerobic plate count contamination was 2 or 3 for carcasses but 0 for personnel and equipment in almost all slaughterhouses. A score of 0 on carcasses was mostly attributed to Enterobacteriaceae at evisceration and to Salmonella at dehiding and evisceration. In addition, a score of 0 was mostly attributed to Staphylococcus contamination of personnel at dehiding. A score of 3 was attributed mostly to Enterobacteriaceae on hands at splitting, whereas a score of 2 was mostly attributed to the clothes at dehiding and evisceration. A CL score of 3 was mostly attributed to Enterobacteriaceae and Salmonella contamination of equipment at dehiding and splitting, respectively. Although CLs attributed to contamination of carcasses, personnel, and equipment ranged from 0 to 3, the maximum MCLP score of 9 was only attained in carcasses from two slaughterhouses at dehiding and from one slaughterhouse at dispatch. There is, therefore, a lot of room for small and medium enterprise slaughterhouses to improve their food safety objectives by improving food safety management systems at the points characterized by low CL scores.

  16. Automated contamination monitoring for hot particles

    International Nuclear Information System (INIS)

    Johnstone, G.; Case, L.

    1987-01-01

    INS Corp., the largest nuclear laundry company in the United States, has recently developed two types of automated contamination monitoring systems: 1) the Automated Laundry Monitor (ALM), which provides quality assurance monitoring for protective clothing contamination and 2) a low-level automated monitoring system for Plastic Volume Reduction Service (PVRS). The presentation details the inaccuracies associated with hand-probe frisking which led to the development of the ALM. The ALM was designed for 100% quality assurance monitoring of garments to the most stringent customer requirements. A review of why the ALM is essential in verifying the absence of hot particles on garments is given. The final topic addresses the expansion of the ALM technology in support of the INS Plastic Volume Reduction Service by monitoring decontaminated plastics to free release levels. This presentation reviews the design and operation of both monitoring systems

  17. Optimization of monitoring sewage with radionuclide contaminants

    International Nuclear Information System (INIS)

    Egorov, V.N.

    1991-01-01

    Recommendations on optimization of monitoring contaminated sewage aimed at enviromental protection agxinst radioactive contamination at minimum cost are presented. The way of selecting water sampling technique depends on water composition stability and flow rate. Depending on the type of radionuclide distribution in the sewage one can estimate minimum frequency of sampling or number of samples sufficient for assuring reliability of the conclusion on the excess or non-excess of permissible radioactive contamination levels, as well as analysis assigned accuracy. By irregular contaminated sewage-discharge and possibility of short-term releases of different form and duration, sampling should be accomplished through automatic devices of continuons or periodic operation

  18. Monitoring and evaluation techniques for airborne contamination

    Energy Technology Data Exchange (ETDEWEB)

    Yihua, Xia [China Inst. of Atomic Energy, Beijing (China)

    1997-06-01

    Monitoring and evaluation of airborne contamination are of great importance for the purpose of protection of health and safety of workers in nuclear installations. Because airborne contamination is one of the key sources to cause exposure to individuals by inhalation and digestion, and to cause diffusion of contaminants in the environment. The main objectives of monitoring and evaluation of airborne contamination are: to detect promptly a loss of control of airborne material, to help identify those individuals and predict exposure levels, to assess the intake and dose commitment to the individuals, and to provide sufficient documentation of airborne radioactivity. From the viewpoint of radiation protection, the radioactive contaminants in air can be classified into the following types: airborne aerosol, gas and noble gas, and volatile gas. In this paper, the following items are described: sampling methods and techniques, measurement and evaluation, and particle size analysis. (G.K.)

  19. Monitoring and evaluation techniques for airborne contamination

    International Nuclear Information System (INIS)

    Xia Yihua

    1997-01-01

    Monitoring and evaluation of airborne contamination are of great importance for the purpose of protection of health and safety of workers in nuclear installations. Because airborne contamination is one of the key sources to cause exposure to individuals by inhalation and digestion, and to cause diffusion of contaminants in the environment. The main objectives of monitoring and evaluation of airborne contamination are: to detect promptly a loss of control of airborne material, to help identify those individuals and predict exposure levels, to assess the intake and dose commitment to the individuals, and to provide sufficient documentation of airborne radioactivity. From the viewpoint of radiation protection, the radioactive contaminants in air can be classified into the following types: airborne aerosol, gas and noble gas, and volatile gas. In this paper, the following items are described: sampling methods and techniques, measurement and evaluation, and particle size analysis. (G.K.)

  20. Healthcare personnel perceptions of hand hygiene monitoring technology.

    Science.gov (United States)

    Ellingson, Katherine; Polgreen, Philip M; Schneider, Amy; Shinkunas, Laura; Kaldjian, Lauris C; Wright, Donald; Thomas, Geb W; Segre, Alberto M; Herman, Ted; McDonald, L Clifford; Sinkowitz-Cochran, Ronda

    2011-11-01

    To assess healthcare personnel (HCP) perceptions regarding implementation of sensor-based electronic systems for automated hand hygiene adherence monitoring. Using a mixed-methods approach, structured focus groups were designed to elicit quantitative and qualitative responses on familiarity, comfort level, and perceived impact of sensor-based hand hygiene adherence monitoring. A university hospital, a Veterans Affairs hospital, and a community hospital in the Midwest. Focus groups were homogenous by HCP type, with separate groups held for leadership, midlevel management, and frontline personnel at each hospital. Overall, 89 HCP participated in 10 focus groups. Levels of familiarity and comfort with electronic oversight technology varied by HCP type; when compared with frontline HCP, those in leadership positions were significantly more familiar with ([Formula: see text]) and more comfortable with ([Formula: see text]) the technology. The most common concerns cited by participants across groups included lack of accuracy in the data produced, such as the inability of the technology to assess the situational context of hand hygiene opportunities, and the potential punitive use of data produced. Across groups, HCP had decreased tolerance for electronic collection of spatial-temporal data, describing such oversight as Big Brother. While substantial concerns were expressed by all types of HCP, participants' recommendations for effective implementation of electronic oversight technologies for hand hygiene monitoring included addressing accuracy issues before implementation and transparent communication with frontline HCP about the intended use of the data.

  1. Personnel radiation monitoring by thermoluminescence dosimetry (1995-96)

    International Nuclear Information System (INIS)

    Daw Mi Cho Cho; Daw Yi Yi Khin; Daw San San; U Maung Maung Tin; Daw Hla Hla Win

    2001-01-01

    Personnel radiation monitoring which is the dose assessment of individual doses from external radiation received by radiation workers has been carried out by Thermoluminescence Dosimetry system consisting of a Vinten Toledo TLD reader, LiF dosimeters and associated equipment. The exposed TLD dosimeters were measured by TLD reader and the dose evaluation and dose registration were done on personal computer. Due to the records of 1995-96, most of the radiation workers complied with the permissible dose recommended by IAEA and ICRP 60. (author)

  2. Development of neutron personnel monitoring system based on CR-39 solid state nuclear track detector

    International Nuclear Information System (INIS)

    Massand, O.P.; Kundu, H.K.; Marathe, P.K.; Supe, S.J.

    1990-01-01

    Personnel neutron monitoring aims at providing a method to evaluate the magnitude of the detrimental effects on the personnel exposed to neutrons. Neutron monitoring is done for a small though growing number of personnel working with neutrons in a wide range of situations. Over the years, many solid state nuclear track detectors (SSNTD) have been tried for neutron personnel monitoring. CR-39 SSNTD is a proton sensitive polymer and offers a lot of promise for neutron personnel monitoring due to its high sensitivity and lower energy threshold for neutron detection. This report presents the mechanism of track formation in this polymer, the development of this neutron personnel monitoring system in our laboratory, its various characteristics and its promise as a routine personnel neutron monitor. (author). 1 tab., 7 figs

  3. The status on contamination monitoring in Thailand

    Energy Technology Data Exchange (ETDEWEB)

    Sinakhom, Fookiat [Office of Atomic Energy for Peace, Bangkok (Thailand)

    1997-06-01

    Thailand has embarked upon the development of nuclear energy for peaceful utilizations since 1961 when the Atomic Energy for Peace Act was enacted. The Atomic Energy Commission (Thai AEC) was established under section 5 of this Act having power and duty of carrying out matters concerning atomic energy for peace. The applications of nuclear energy in Thailand, at present are exclusively in medicine, education, research and industry. In this paper, the following items are described on contamination monitoring: controllable monitoring, uncontrollable monitoring, standardization of monitoring instruments, and decontamination and waste management. (G.K.)

  4. Preliminry results of the 1975 international personnel monitoring survey

    International Nuclear Information System (INIS)

    Becker, K.

    1975-11-01

    About 70 detailed questions have been answered in mid-1975 by 83 personnel monitoring services in 33 countries, representing almost half a million, or approximately 28 percent, of the world's total radiation workers, as well as by 11 customers of U. S. commercial services. Extensive data are given on many questions regarding the current system in use, future plans, and experiences, for example on the type(s) of TLD, film and readout instrumentation; monitoring period; applications for extremity and environmental monitoring; advantages and disadvantages of various systems; R and D projects; experience with beta and neutron dosimetry; intentional fake exposures; lower and upper dose limits; recordkeeping; and reporting of the results. The larger services in the advanced countries lead in the transition from film to TLD. More than half of the radiation workers already wear TLDs, or will do so within about two years. Important unsolved problems are fast neutron monitoring and the low information content and high initial cost of TLD. The trend is towards large, centralized, automatic services and recordkeeping, with extensive computer use for evaluation and data handling. There is a need for better performance standards and testing, and more information exchange and cooperation between services. (auth)

  5. Development of optically stimulated luminescence technology for personnel monitoring applications at Bhabha Atomic Research Centre

    International Nuclear Information System (INIS)

    Kulkarni, M.S.

    2012-01-01

    The popularity of optically stimulated luminescence (OSL) technology in the radiation dosimetry applications, in general, and personnel and environmental monitoring, in particular, has driven investigation and developmental programme using OSL technique for a viable system for personnel monitoring at Bhabha Atomic Research Centre. The OSL related phosphor materials and instrumentation development has a very recent history in Bhabha Atomic Research Centre. The OSL technique is more versatile and easy to use than thermoluminescence (TL) technique. The X- and gamma ray (both high and low energy) photons and beta particles can be measured with OSL technique. In the OSL technique, the phosphor (say á- Ai 2 O 3 :C) is optically stimulated by blue/green light and the resulting light emitted from Al 2 O 3 :C (410-420 nm) is measured and correlated to the amount of radiation exposure. For a fixed stimulation intensity, the emitted blue light from the Al 2 O 3 :C dosimeter is proportional to the radiation exposure. The OSL technology is being increasingly used in several applications in external radiation dosimetry, in-vivo medical dosimetry in radiotherapy, in-situ, long-term monitoring system for radioactive contaminants, geological and archaeological dating of sediments, etc. For the success of OSL technology for large scale countrywide personnel monitoring program, indigenous development of dosimetric grade sensitive detector material was a key issue. Therefore, since 2002, efforts were directed towards the development of OSL phosphors (like aluminum oxide doped with carbon, á- Al 2 O 3 :C) and related instrumentation. To begin with, simple low cost OSL readers were developed using blue (470 nm) and green (530 nm) LED clusters. New techniques were developed for the preparation of dosimetric grade á- Ai 2 O 3 :C and other OSL phosphors. With the success in the development of indigenous technique for the large scale preparation of á- Al 2 O 3 :C phosphor, a four

  6. Radioactive contamination in monitors received for calibration

    International Nuclear Information System (INIS)

    Dias, Paulo S.; Santos, Gilvan C. dos; Brunelo, Maria Antonieta G.; Paula, Tiago C. de; Pires, Marina A.; Borges, Jose C.

    2013-01-01

    The Calibration Laboratory - LABCAL, from the Research Center for Metrology and Testing - METROBRAS, MRA Comercio de Instrumentos Eletronicos Ltda., began activities in October 2008 and, in August 2009, decided to establish a procedure for monitoring tests, external and internal, of all packages received from customers, containing instruments for calibration. The aim was to investigate possible contamination radioactive on these instruments. On July 2011, this procedure was extended to packagings of personal thermoluminescent dosemeters - TLD, received by the newly created Laboratory Laboratorio de Dosimetria Pessoal - LDP . In the monitoring procedure were used monitors with external probe, type pancake, MRA brand, models GP - 500 and MIR 7028. During the 37 months in which this investigation was conducted, were detected 42 cases of radioactive contamination, with the following characteristics: 1) just one case was personal dosimeter, TLD type; 2) just one case was not from a packing from nuclear medicine service - was from a mining company; 3) contamination occurred on packs and instruments, located and/or widespread; 4) contamination values ranged from slightly above the level of background radiation to about a thousand fold. Although METROBRAS has facilities for decontamination, in most cases, especially those of higher contamination, the procedure followed was to store the contaminated material in a room used for storage of radioactive sources. Periodically, each package and/or instrument was monitored, being released when the radiation level matched the background radiation. Every contamination detected, the client and/or owner of the instrument was informed. The Brazilian National Energy Commission - CNEN, was informed, during your public consultation for reviewing the standard for nuclear medicine services, held in mid-2012, having received from METROBRAS the statistical data available at the time. The high frequency of contamination detected and the high

  7. ESI nuclear model 271 C contamination monitor

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1978-06-01

    This instrument is a general purpose contamination monitor, comprising a GM tube connected by a coiled extensible cable to a ratemeter. The scale is marked quasi-logarithmically from 0 to 600 in 'counts per second'. The report falls under the headings: general description, facilities and controls, radiation performance, electrical characteristics, environmental characteristics, mechanical characteristics, summary of performance, conclusions. (U.K.)

  8. Status of contamination monitoring in Bangladesh

    Energy Technology Data Exchange (ETDEWEB)

    Begum, Aleya [Institute of Nuclear Science and Technology, Savar, Dacca (Bangladesh)

    1997-06-01

    The applications of radioisotopes and radiation sources to the research and development in medicine, food agriculture, industries and others are rapidly increasing in Bangladesh. The existing major nuclear facilites and allied laboratories of the country include 3 MW TRIGA Mark-2 research reactor for training, research and radioisotope production, 14 MeV neutron generator for nuclear data measurement and elemental analysis via neutron activation, 3 MeV Van de Graaff accelerator for the research and application of nuclear physics, and 50,000 Ci and 5,000 Ci Co-60 irradiators. About 10 Co-60 and Cs-137 teletherapy units are in operation in hospitals. The radioactive contamination of working areas, equipment, protective clothing and skin may result from normal operation and accidents, and contamination monitoring and decontamination are the essential part of radiation protection program. Surface contamination is monitored with Berthold survey meters. Hand and foot monitors have been used. Routine systematic search, continuous air monitoring, the examination of silt movement in Chittagong harbor using Sc-46 tracer and the measurement of tritium contamination for the neutron generator are reported. (K.I.)

  9. GSFC contamination monitors for Space Station

    Science.gov (United States)

    Carosso, P. A.; Tveekrem, J. L.; Coopersmith, J. D.

    1988-01-01

    This paper describes the Work Package 3 activities in the area of neutral contamination monitoring for the Space Station. Goddard Space Flight Center's responsibilities include the development of the Attached Payload Accommodations Equipment (APAE), the Polar Orbiting Platform (POP), and the Flight Telerobotic Servicer (FTS). GSFC will also develop the Customer Servicing Facility (CSF) in Phase 2 of the Space Station.

  10. Evaluation of the secondary radiation impact on personnel during the dismantling of contaminated nuclear equipment

    Directory of Open Access Journals (Sweden)

    Stankunas Gediminas

    2013-01-01

    Full Text Available The article contains a numerical analysis of the secondary radiation contribution to the total radiation affecting the operational personnel during the dismantling activities of the contaminated equipment at a nuclear power plant. This study considers a widely applicable Monte Carlo particle transport code MCNPX and real Ignalina nuclear power plant records. A simplified albedo method is investigated in order to analyze the selected geometrical design cases. Additionally, the impact of the secondary radiation on the personnel dose was analyzed. The numerical MCNPX simulation allowed ascertaining the optimal distance between the source and the wall for the working personnel in closed rooms with contaminated equipment. The developed dose rate maps of the secondary radiation showed cross-sectional distribution of the dose rate inside the enclosed area.

  11. Quality assurance for external personnel monitoring in nuclear industrial facilities, CNNC

    International Nuclear Information System (INIS)

    Zhang Yansheng; Dai Jun; Li Taosheng

    1993-01-01

    More than 6000 personnel are currently being monitored for occupational exposure in CNNC, China. Personnel monitoring is one of the important items of radiation protection. The data of individual dose are not only indispensable for radiation safety assessment but also the basis for radiation protection measures to be taken. Possibly, it could provide basic information for epidemiological studies, optimization procedure of radiation protection (risk/benefit analyses) and medical or legal purposes. Obviously, personnel monitoring and its quality assurance are very significant

  12. Immunological monitoring of the personnel at radiation hazardous facilities

    International Nuclear Information System (INIS)

    Kiselev, S.M.; Sokolnikov, M.E.; Lyss, L.V.; Ilyina, N.I.

    2017-01-01

    The study of possible mechanisms resulting in changes in the immune system after exposure to ionizing radiation is an area that has not been thoroughly evaluated during recent years. This article presents an overview of immunological monitoring studies of personnel from the radiation-hazardous factories that took place over the past 20 years in Russia. The methodology of these studies is based on: (1) the preclinical evaluation of immune status of workers whose occupation involves potential exposure to ionizing radiation; (2) selecting at risk groups according to the nature of immune deficiency manifestation; and (3) studying the changes of immune status of employees with regard to the potential effects of radiation exposure. The principal aim of these studies is accumulation of new data on the impact of radiation exposure on the human immune system and search for the relationship between the clinical manifestations of immune disorders and laboratory parameters of immunity to improve the monitoring system of the health status of the professional workers involved in radiation-hazardous industrial environments and the population living close to these facilities. (authors)

  13. Radiation exposure of non-monitored hospital personnel

    International Nuclear Information System (INIS)

    Renaud, L.; Blanchette, J.; Galand, C.

    1993-02-01

    This project investigated the radiological impact of nuclear medicine patients on non-monitored personnel in hospital environments. More than 800 workers and 135 specific areas in three Quebec hospitals were surveyed daily during a six-month period with Geiger counters, TLD badges, and TLD chips. Average dose rates of up to 2.2 μSv/h were measured in some waiting areas. The radiation level of a nursing unit is a direct function of the ambulatory radioactivity carried by nuclear medicine patients. Three percent of the workers surveyed had a work-related dose in excess of 0.3 mSv/6 months (maximum 1.4 mSv/6 months). Over 88 percent were in the range between local background and 0.3 mSv/6 months. Less than 4 percent belong to groups of workers who were exposed to a level indistinguishable from background. Thus many workers surveyed in this study receive a work-related dose similar to those of medical workers monitored by Health and Welfare Canada. The average annual dose for these workers was 104 person-millisieverts. The authors recommend: better management of radioactive patients; the provision of information and education for all hospital workers having regular contact with radioactive patients; and the facilitation of the identification of nuclear medicine patients within the hospital environment. (28 tabs., 23 figs.)

  14. Investigation of internal contamination by tritium in A-1 nuclear power plant personnel in 1974

    International Nuclear Information System (INIS)

    Ondris, D.; Herchl, M.; Homolova, E.

    1977-01-01

    The results are presented of the 1974 personnel monitoring of the Bohunice A-1 nuclear power plant staff for internal contamination with tritium. Totally, 650 urine samples taken from 103 workers were analyzed using the recommended ICRP procedure. In routine examinations, the highest dose equivalent value of tritium incorporated within two weeks did not exceed 10 mrem, i.e., the maximum annual dose equivalent did not exceed 260 mrem. 8.5 μCi tritium per 1 litre urine was considered to be an alarm value. In a selected group of 21 high-risk persons analyses were conducted before and after each operation associated with tritium hazards. The limit dose was set to 5.8 μCi.l -1 , i.e., the tritium concentration equivalent to 10% of the maximum permissible annual intake. In 18 workers where tritium risk was of a more serious nature the biological half-life was followed up, with the average biological half-life being 8.5 days, with 5 days for the minimum and 12 days for the maximum values. The results show that in 1974 the tritium burden did not exceed 1/10 of the maximum permissible dose for any of the A-1 nuclear power plant workers. (L.O.)

  15. Small mammals as monitors of environmental contaminants

    International Nuclear Information System (INIS)

    Talmage, S.S.; Walton, B.T.

    1991-01-01

    The merit of using small mammals as monitors of environmental contaminants was assessed using data from the published literature. Information was located on 35 species of small mammals from 7 families used to monitor heavy metals, radionuclides, and organic chemicals at mine sites, industrial areas, hazardous and radioactive waste disposal sites, and agricultural and forested land. To document foodchain transfer of chemicals, concentrations in soil, vegetation, and invertebrates, where available, were included. The most commonly trapped North American species were Peromyscus leucopus, Blarina brevicauda, and Microtus pennsylvanicus. In these species, exposure to chemicals was determined from tissue residue analyses, biochemical assays, and cytogenetic assays. Where enough information was available, suitable target tissues, or biological assays for specific chemicals were noted. In general, there was a relationship between concentrations of contaminants in the soil or food, and concentrations in target tissues of several species. This relationship was most obvious for the nonessential heavy metals, cadmium, lead, and mercury and for fluoride. Kidney was the single best tissue for residue analyses of inorganic contaminants. However, bone should be the tissue of choice for both lead and fluorine. Exposure to lead was also successfully documented using biochemical and histopathological endpoints. Bone was the tissue of choice for exposure to 90Sr, whereas muscle was an appropriate tissue for 137Cs. For organic contaminants, exposure endpoints depended on the chemical(s) of concern. Liver and whole-body residue analyses, as well as enzyme changes, organ histology, genotoxicity, and, in one case, population dynamics, were successfully used to document exposure to these contaminants

  16. Methicillin-resistant staphylococcal contamination of cellular phones of personnel in a veterinary teaching hospital

    Directory of Open Access Journals (Sweden)

    Julian Timothy

    2012-07-01

    Full Text Available Abstract Background Hospital-associated infections are an increasing cause of morbidity and mortality in veterinary patients. With the emergence of multi-drug resistant bacteria, these infections can be particularly difficult to eradicate. Sources of hospital-associated infections can include the patients own flora, medical staff and inanimate hospital objects. Cellular phones are becoming an invaluable feature of communication within hospitals, and since they are frequently handled by healthcare personnel, there may be a potential for contamination with various pathogens. The objective of this study was to determine the prevalence of contamination of cellular phones (hospital issued and personal carried by personnel at the Ontario Veterinary College Health Sciences Centre with methicillin-resistant Staphylococcus pseudintermedius (MRSP and methicillin-resistant Staphylococcus aureus (MRSA. Results MRSP was isolated from 1.6% (2/123 and MRSA was isolated from 0.8% (1/123 of cellular phones. Only 21.9% (27/123 of participants in the study indicated that they routinely cleaned their cellular phone. Conclusions Cellular phones in a veterinary teaching hospital can harbour MRSP and MRSA, two opportunistic pathogens of significant concern. While the contamination rate was low, cellular phones could represent a potential source for infection of patients as well as infection of veterinary personnel and other people that might have contact with them. Regardless of the low incidence of contamination of cellular phones found in this study, a disinfection protocol for hospital-issued and personal cellular phones used in veterinary teaching hospitals should be in place to reduce the potential of cross-contamination.

  17. Statistical considerations in practical contamination monitoring

    International Nuclear Information System (INIS)

    Brodsky, A.; Gallaghar, R.G.

    1991-01-01

    This paper reports on an examination of smear survey practices which indicates that many radiation safety programs are lacking in important aspects of contamination monitoring. In order to satisfy regulatory and potential litigatory requirements, smear surveys should include the measurement and recording of the flowing data: area of each smear and smear procedure (by reference); total counts on smear and counting procedure; total counts on appropriate blanks and description of blank; total counts on standard and specifications of standard; and all counting times. The rationale for these smear survey requirements is obtained by examining the formulation of the minimum detectable amount (MDA) on a smear

  18. Radioactive standards and calibration methods for contamination monitoring instruments

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Makoto [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-06-01

    Contamination monitoring in the facilities for handling unsealed radioactive materials is one of the most important procedures for radiation protection as well as radiation dose monitoring. For implementation of the proper contamination monitoring, radiation measuring instruments should not only be suitable to the purpose of monitoring, but also be well calibrated for the objective qualities of measurement. In the calibration of contamination monitoring instruments, quality reference activities need to be used. They are supplied in different such as extended sources, radioactive solutions or radioactive gases. These reference activities must be traceable to the national standards or equivalent standards. On the other hand, the appropriate calibration methods must be applied for each type of contamination monitoring instruments. In this paper, the concepts of calibration for contamination monitoring instruments, reference sources, determination methods of reference quantities and practical calibration methods of contamination monitoring instruments, including the procedures carried out in Japan Atomic Energy Research Institute and some relevant experimental data. (G.K.)

  19. Requirements for internal contamination monitoring units

    International Nuclear Information System (INIS)

    Werner, E.; Beyer, D.; Doerfel, H.; Erlenbach, H.; Fischbach, G.; Henrichs, K.; Keller, K.D.; Koenig, K.; Riedel, W.; Scheler, R.; Schieferdecker, H.

    1994-01-01

    For the evaluation of internal contamination by officially authorized monitoring units according to section 63 (6) of the German radiation protection ordinance, a directive will be prepared in order to define uniform requirements for the laboratories in charge of incorporation monitoring by appointment of the relevant authorities. These requirements refer to equipment, to performance of measurements, to interpretation of measured values, to quality control as well as to documentation and to delivery of results. The duties of such laboratories comprise measurements of radioactivity, evaluation of intakes of radionuclides and of the resulting internal radiation dose, but also transmission of results to the employer, to the central dose registry, and under certain circumstances to the authorities. Among the requirements to be met by the laboratory for incorporation control are a sufficient measuring efficiency, the implementation of in-house checks, and the participation in intercomparison programs. For the accomplishment of such duties the laboratory needs appropriate apparatus, rooms, facilities, and staffing. (orig.) [de

  20. Radiation exposure of non-monitored hospital personnel

    International Nuclear Information System (INIS)

    Renaud, L.; Blanchette, J.; Galand, C.

    1993-02-01

    This addendum to report INFO--0437-1 reports the raw results of phase 2 of the survey of medical personnel exposed to nuclear medicine patients. It also presents floor plans of the three hospitals surveyed. (L.L.) (42 tabs., 36 figs.)

  1. A microcontroller based readout unit for a smart personnel monitoring TLD badge

    International Nuclear Information System (INIS)

    Gaonkar, U.P.; Kulkarni, M.S.; Kannan, S.

    1997-01-01

    An automated TLD personnel monitoring system is under development to cope up with the requirements of personnel monitoring of rapidly growing number of radiation workers. The core of the system is a smart TLD badge incorporating a memory device and a microcontroller based readout unit for reading the memory contents of the badge. The memory is used to store personnel data including the accumulated dose data. The reader unit has a serial RS 232C interface for connection to a PC for entering/modifying data in the memory. A password protected software has also been developed in C for entering/modifying the data in the single memory. 3 figs

  2. Harmful effects of DU in the offspring of the military personnel employed in DU contaminated regions

    International Nuclear Information System (INIS)

    Atlagic, N.; Lisov, Lj.; Barjaktarovic, V.; Djurovic, B.; Spasic, Jokic V.

    2008-01-01

    Full text: In 1999, during the NATO attacks on Kosovo, from AT-10 aircraft has been shot over 50000 30-mm projectiles which contained approximately 15 tones of DU. Besides DU, projectiles contained products of DU radioactive decay as well as americium, neptunium, plutonium and technetium. Due to DU contamination military personnel employed near hit targets could be contaminated and irradiated. Besides the harmful effects in exposed military personnel, harmful effects were noticed in their offsprings, too. DU can cause genetic and teratogenic harmful effects in the embryos/fetus. It is concentrated in semen of contaminated males and also can contaminate the embryo/fetus through placenta. DU, as a toxic and radioactive element, can cause variety of harmful effects, but the most important are the effects on DNA which are the cause of many diseases. The aim of this paper is to examine is there any change in the incidence in heritable effects, congenital malformations, malignant diseases, endocrine and immune disorders. For that reason we compared the incidence of these diseases in the offspring's of military personnel born from 1995-1999 (1204) with the children born from 2000-2004 (1131) / and 2005-2008. Our results showed higher incidence of congenital malformations and chromosomal abnormalities (12.55 % vs 4.57 %), with highest incidence of foot deformity-52.04 % and hip deformity. These abnormalities were followed with immunological disorders and dysfunction of the urine bladder. Endocrine diseases were increased too(2.16 % :1.63 %). In this period higher incidence of malignant diseases was not noticed, but in the second period (from 5-9 year) after 1999, higher incidence of malignant hematological diseases was noticed, as well as Down Sy. During the conflicts future parents as well as embryo/fetus are exposed to many harmfulness and it is very hard to separate the influence of each. Considering the fact that the effects of DU, could be delayed and synergistic with

  3. Chapter 7. Monitoring of chemical contamination of the environment and analytical-chemical monitoring

    International Nuclear Information System (INIS)

    Sojak, L.

    2006-01-01

    This chapter deals with the monitoring of chemical contamination of the environment and analytical-chemical monitoring. There are presented: the concept o monitoring of the environment of the Slovak Republic; unified monitoring system and complex information about state and development of the environment; analytical methods determination of chemical contaminants in the environment

  4. Monitoring of atmospheric contamination by plutonium in laboratories

    International Nuclear Information System (INIS)

    Pomarola, J.; Risselin, A.; Feliers, P.

    1965-02-01

    Immediate detection of atmospheric contamination by plutonium is necessary for warning of operators. A precise estimate of the level of this contamination is also necessary in order to give the Medical Section proper information. Experiments have been carried out at CEN-FAR using atmospheric contamination by plutonium monitors. This paper deals successively with: important problems of monitoring, the carrying out of the experiments and the results yielded. (authors) [fr

  5. Quality assurance of the manual OSLD Badge based personnel monitoring system

    International Nuclear Information System (INIS)

    Kumar, Munish; Gaonkar, U.P.; Koul, D.K.; Datta, D.; Singh, S.K.; Rakesh, R.B.; Kulkarni, M.S.; Ratna, P.

    2018-01-01

    Optically stimulated luminescence (OSL) based technique is widely used for monitoring of radiation workers exposed to x, gamma and beta radiations. Features such as multiple readout, short processing time, better beta response, absence of infra red signal (no heating), flexibility in the dosimeter design using binders or substrates having low melting point are associated advantages. Presently α-Al 2 O 3 :C and BeO based dosimeters are popularly used for personnel monitoring applications worldwide. The present paper describe results of the external quality control check (QAC) tests performed for the present OSLD badge based personnel monitoring system. The results were analyzed as per ANSI criteria and Trumpet curve methods

  6. Periodicity of TLD badge personnel monitoring service in India

    International Nuclear Information System (INIS)

    Kher, R.K.; Joshi, V.D.; Kaushik, Aruna; Sharma, Amiy; Chatterjee, S.

    2003-01-01

    The periodicity of an individual monitoring service is an important aspect. Presently minimum period for TLD badge service is maintained as 'calendar month' and choice of quarterly service is also offered. The periodicity of the TLD service for a given category/application type of institution, is to be fixed taking into account level of average occupational doses in all or typical institutions of given category and other information indicating the status of safety and possible fluctuations of exposure levels and potential for overexposure cases. This paper presents the status on the periodicity of TLD Badge Service as is evolved and adopted for the four broad categories i.e. DAE (Nuclear Fuel Cycle) Institutions, Industrial, Medical, Research institutions. It is concluded that quarterly service is a convenient option for institution categories where type of work/workload, and work practices are such that occupational exposures could be normally kept below about one mSv or so in the monitoring period, average annual dose less than 1 mSv and persons receiving annual dose >10 mSv is less than 1% of total in the category. Also, the judicious use of the flexibility in the periodicity of TLD Badge service would help (i) to keep the monitoring related workload to the optimum for the monitoring units and (ii) to keep the expenses incurred by the institution towards monitoring to the minimum without sacrificing radiation safety (iii) to focus the extra monitoring efforts on the applications/situations requiring improvement in radiation safety. (author)

  7. Personnel contamination protection techniques applied during the TMI-2 [Three Mile Island Unit 2] cleanup

    International Nuclear Information System (INIS)

    Hildebrand, J.E.

    1988-01-01

    The severe damage to the Three Mile Island Unit 2 (TMI-2) core and the subsequent discharge of reactor coolant to the reactor and auxiliary buildings resulted in extremely hostile radiological environments in the TMI-2 plant. High fission product surface contamination and radiation levels necessitated the implementation of innovative techniques and methods in performing cleanup operations while assuring effective as low as reasonably achievable (ALARA) practices. The approach utilized by GPU Nuclear throughout the cleanup in applying protective clothing requirements was to consider the overall health risk to the worker including factors such as cardiopulmonary stress, visual and hearing acuity, and heat stress. In applying protective clothing requirements, trade-off considerations had to be made between preventing skin contaminations and possibly overprotecting the worker, thus impacting his ability to perform his intended task at maximum efficiency and in accordance with ALARA principles. The paper discusses the following topics: protective clothing-general use, beta protection, skin contamination, training, personnel access facility, and heat stress

  8. Health surveillance of personnel engaged in decontamination of depleted uranium contaminated regions

    Energy Technology Data Exchange (ETDEWEB)

    Djurovic, B. [Military Medical Academy, Radiological Protection Dept., Belgrade, Serbia and Montenegro (Yugoslavia); Spasic-Jokic, V. [ESLA Accelerator Installation, Lab. of Physics, VINCA Institute of Nuclear Sciences, Belgrade, Serbia and Montenegro (Yugoslavia); Fortuna, D.; Milenkovic, M. [NBH Military Educational Center, Krusevac, Serbia and Montenegro (Yugoslavia)

    2006-07-01

    After the NATO actions against Serbia and Montenegro, 112 locations were highly contaminated with depleted uranium-112 locations in Kosovo, 7 in the south of Serbia and 1 in Montenegro. Contaminated regions were marked, isolated and some of them decontaminated. In this paper we present the health surveillance protocol created for personnel engaged in decontamination of contaminated regions of Pljackovica and Bratoselce. They were examined and selected before decontamination and only healthy professionals (36 and 28) were engaged. Examination included: general clinical assessment, complete blood count with differential white blood cells; biochemical analysis of blood and urine, specifically renal and liver functions tests, cytogenetic tests (chromosomal aberration and micronucleus test), and laser fluorometry of 24-h urine sample and gamma spectrometry of the same if the levels were elevated. After the decontamination in the first group no clinical or biochemical changes were found, but in 3 of 36 were found unstable chromosomal aberrations. In the second group, in 3 of 28 were found unstable chromosomal aberrations and in 3 of them laser fluorometry analysis showed elevated levels of uranium (>3 {mu}g/l in two, and >5 {mu}g/l in one of them). Gamma spectrometry showed that it was not depleted, but naturally occurring uranium. Additionally performed analysis showed they were from the same village which is in the zone of highly elevated uranium level in ground and water. Three months later no chromosomal changes were found. (authors)

  9. Emergency preparedness and internal contamination monitoring

    International Nuclear Information System (INIS)

    Rahola, T.; Suomela, M.

    2000-01-01

    After the radiation accidents in Chernobyl, Ukraina in 1986 and in Goiania, Brasil in 1987, much resource have been spent on improving emergency preparedness. Especially regarding transfer of information using the most recent techniques and establishment of 24 hour emergency service of radiation safety experts the development has been fast. The very first measures in a possible emergency situation have been trained nationally and internationally. Less attention has been paid to measures in a somewhat later phase. To be able to react fast enough in an emergency situation it is essential to have well documented plans, written instructions and suitable measurement equipment ready for use. Equally important is that there is trained staff prepared to do measurements without delay. In the first phase of a nuclear accident radioactive iodine is of primary concern regarding internal contamination. After the Chernobyl accident the number of childhood thyroidea cancer clearly exceeded the expected number. Reliable direct measurements of I-131 in the thyroidea in Ukraina, Russia and Belarussia were done only to a limited number of children. Many uncertainties are involved in the data used for dose estimation. Later the body burdens of radiocesium or other radionuclides might be of most importance. Normal whole-body counting instruments can be used if only small groups need to be measured. For large groups of people in an emergency situation faster methods are needed. Different types of monitors installed at places where radiation workers are controlled for internal contamination as well as gamma cameras at hospitals can be used. Rapid field measurements of the whole-body and especially of the thyroid can been done with less sophisticated instruments. In the acute phase of a nuclear accident such measurements should be done without delay. Instruments and staff trained to use them should be available and plans for which groups of people to measure prepared. The detection level

  10. An approach to routine individual internal dose monitoring at the object 'Shelter' personnel considering uncertainties

    International Nuclear Information System (INIS)

    Mel'nichuk, D.V.; Bondarenko, O.O.; Medvedjev, S.Yu.

    2002-01-01

    An approach to organisation of routine individual internal dose monitoring of the personnel of the Object 'Shelter' is presented in the work, that considers individualised uncertainties. In this aspect two methods of effective dose assessment based on bioassay are considered in the work: (1) traditional indirect method at which application results of workplace monitoring are not taken into account, and (2) a combined method in which both results of bioassay measurements and workplace monitoring are considered

  11. Impact of ANSI 2009 criteria for performance testing in TLD personnel monitoring

    International Nuclear Information System (INIS)

    MeenaI, P.; Rakesh, R.B.; Srivastava, Kshama; KoIambe, D.H.; Sapra, B.K.

    2014-01-01

    External Quality Assurance in TLD Personnel Monitoring Service was initiated in 1985, for periodic performance evaluation of various TLD Laboratories through postal exercise. Presently, all the 16 laboratories involved in Personnel Monitoring Service are covered under QA exercise. Since beginning, American National Standards Institute (ANSI) criteria have been adopted for performance testing in QA exercise. Presently, ANSI 2001 performance criteria along with ISO trumpet curve analysis method are being used for performance evaluation. In 2009, ANSI modified the performance evaluation criteria and this study evaluates its impact and feasibility of implementation of ANSI 2009 criteria in the quality assurance program for personnel monitoring. The performance of some laboratories evaluated using both ANSI 2001 and ANSI 2009 criteria have been discussed. The study shows that the ANSI 2009 criteria is more stringent and encourages even distribution of bias and standard deviation. This can be implemented with suitable modifications for performance evaluation

  12. Personnel monitoring of DAE workers in Andhra Pradesh

    International Nuclear Information System (INIS)

    Padma Savitri, P.; Bhattacharya, Madhumita; Reddy, K.S.; Chourasiya, G.

    2008-01-01

    Occupational exposure to radiation occurs in an organization, which involves work with radioactive sources directly or indirectly. It is recognized that radiation protection is only one component that must be addressed to protect the overall health and safety of the workers. Radiation monitoring is one of the key issues in radiological protection. TLD Unit, Hyderabad is part of the Radiological Physics and Advisory Division, HS and E group, BARC and has been functioning at Nuclear Fuel Complex, Hyderabad since 1985. The unit monitors external dose to 1800 occupation workers from six Department of Atomic Energy units namely Nuclear Fuel Complex, Atomic Minerals Division, Electronic Corporation of India Limited, National Centre for Composition and Characterization of Materials, JONAKI, Hospital in Heavy Water Plant, Manuguru of Andhra Pradesh. This paper analyses dose distribution of radiation workers working in DAE facilities of Andhra Pradesh since the services started to the respective institutions. Excessive exposures of radiation cases are also presented in this paper. (author)

  13. Using signal ''KVANT-1'' direct-reading dosemeter for the purposes of personnel monitoring

    International Nuclear Information System (INIS)

    Glinskij, G.A.; Karasev, V.S.; Mukhin, I.E.; Chumak, V.K.

    1977-01-01

    Presented is the description of ''KVANT-1'' dosemeter for monitoring personnel doses of gamma and X radiation. The dosemeter permits to judge on the radiation intensity, to control directly the dose being accumulated, to store the reading of the dose accumulated for a necessary period of time, to obtain sound signal in case of reaching the limit of a pre-set dose. Presented are a general view, block diagram, and the discription of the dosemeter desing and operation. Advantages of the ''KVANT-1'' dosemeter are shown as compared with the conventional personnel monitoring IFK-2,3 and KID-2 dosemeters [ru

  14. Cold Vacuum Drying facility personnel monitoring system design description

    International Nuclear Information System (INIS)

    PITKOFF, C.C.

    1999-01-01

    This document describes the Cold Vacuum Drying Facility (CVDF) instrument air (IA) system that provides instrument quality air to the CVDF. The IA system provides the instrument quality air used in the process, HVAC, and HVAC instruments. The IA system provides the process skids with air to aid in the purging of the annulus of the transport cask. The IA system provides air for the solenoid-operated valves and damper position controls for isolation, volume, and backdraft in the HVAC system. The IA system provides air for monitoring and control of the HVAC system, process instruments, gas-operated valves, and solenoid-operated instruments. The IA system also delivers air for operating hand tools in each of the process bays

  15. Absorption-Edge-Modulated Transmission Spectra for Water Contaminant Monitoring

    Science.gov (United States)

    2016-03-31

    Naval Research Laboratory Washington, DC 20375-5320 NRL/MR/6390--16-9675 Absorption- Edge -Modulated Transmission Spectra for Water Contaminant...ABSTRACT c. THIS PAGE 18. NUMBER OF PAGES 17. LIMITATION OF ABSTRACT Absorption- Edge -Modulated Transmission Spectra for Water Contaminant Monitoring...contaminants, within a volume of sampled solution, requires sufficient sensitivity. The present study examines the sensitivity of absorption- edge

  16. Micro GC's for Contaminant Monitoring in Spacecraft Air, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of this proposal is to create new gas chromatographs (GCs) for contaminant monitoring in spacecraft air that do not require any reagents or special...

  17. Results and discussion of laboratory experiences with different automated TLD readers for personnel monitoring

    International Nuclear Information System (INIS)

    Regulla, D.F.; Drexeler, G.

    Although the film seems to continue serving as the main personnel dosemeter in Germany for the time in sight, the evolution of particularly solid state techniques and their properties are thoroughly considered with respect to a possible generalized application in personnel monitoring. For this reason different automated TLD systems that are commercially available have been investigated in the laboratory in order to find out their usefulness for a largescale or also decentralized service. Along with studying the dosimetrical and apparative parameters, the question has been discussed to which monitoring philosophy these TLD systems seem to fit. It is reported both on experimental experiences achieved as well as on the results of basic discussions that in return influence the discussion about the necessary outfit of personnel TL dosemeters

  18. Application of wireless sensor networks in personnel dosage monitoring system of nuclear power plant

    International Nuclear Information System (INIS)

    Chen Yonghong; Zhang Dafa; Jiang Wei; Chen Dengke

    2007-01-01

    Aim to meet the need of personnel dosage monitoring of nuclear power plant, a monitoring system was designed which based on wireless sensor network. First, the basic concept was described; the characteristics of the wireless sensor network applied in the monitoring system of nuclear power plant were also been analyzed; the structure of the system was built too. Finally, the special technologies like the choice of communication mode, the security of communication network and orientation that used in the monitoring system were discussed. (authors)

  19. Storage of radioactive material - accidents - precipitation - personnel monitoring; Stokiranje radioaktivnih materijala - akcidenti - padavine - kontrola osoblja

    Energy Technology Data Exchange (ETDEWEB)

    Matijasic, A; Gacinovic, O [Institute of Nuclear Sciences Boris Kidric, Radioloska zastita, Vinca, Beograd (Serbia and Montenegro)

    1961-12-15

    This volume covers the reports on four routine tasks concerned with safe handling of radioactive material and influence of nuclear facilities on the environment. The tasks performed were as follows: Storage of solid and liquid radioactive material; actions in case of accidents; radiation monitoring of the fallout, water and ground; personnel dosimetry.

  20. Protection of personnel against atmospheric contamination by plutonium in the laboratory (1963); Protection du personnel contre la contamination atmospherique par le plutonium, dans les laboratoires (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Feliers, P; Pomarola, J; Risselin, A [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1963-07-01

    Various problems about measurement of atmospheric contamination by plutonium in laboratories are considered. In particular are studied sampling methods, continuous measurement for alarm, criteria used for fixation of the concentrations to be measured, sensitivity of apparatus and effects of natural atmospheric contamination. The means actually available for measurement of contamination and their limits of use are briefly analysed. (authors) [French] Les differents problemes a resoudre pour realiser un controle satisfaisant de la contamination atmospherique par le plutonium, dans les laboratoires, sont abordes. On etudie en particulier les differents modes d'echantillonnage, le controle continu en vue de l'alarme, les criteres qui servent a la fixation des concentrations a mesurer, la sensibilite a donner aux moyens de mesure, les difficultes provenant de la contamination atmospherique naturelle. Les moyens actuellement disponibles pour le controle de la contamination et leurs moyens limites d'emploi sont analyses sommairement. (auteurs)

  1. Device for contamination monitoring against radiation contamination of people

    International Nuclear Information System (INIS)

    Rische, U.W.; Gerlach, R.

    1986-01-01

    The monitor has detector devices at an angle to each other made as a rigid component which can be rotated around a vertical axis in the angle between the joined detector devices. A reset drive which can be tensioned is provided at the axis of rotation. If it is in its rest position, a platform is situated as floor plate with a foot detector between the vertical detector devices. (orig./HP) [de

  2. Improvement of a device for monitoring the contamination of surfaces

    International Nuclear Information System (INIS)

    Barbier, Albert.

    1981-01-01

    The purpose of this invention is to make it possible to monitor the contamination of surfaces by a light weight portable device and enabling the alpha, beta and gamma radiation contamination to be detected. The detection probe which is connected by a single lead to the box is adapted, in each particular case, to the radiation mode emitted by the contaminated surfaces and the box is provided with a special leak-proof socket for connecting the probe and includes means for assessing the counting rate of the radiation given off, depending on the mode of the radiations emitted by the contaminated surfaces and the intensity of the count rate [fr

  3. Monitor for alpha beta contamination of hands; Moniteur de contamination alpha beta des mains

    Energy Technology Data Exchange (ETDEWEB)

    Guitton, J

    1958-07-01

    The following specifications of hands alpha beta contamination monitor are presented: the position of the hands, the detection and separation of alpha and beta, the information processing, the programming, the results presentation and general characteristics. (A.L.B.)

  4. Device for contamination monitoring against radiation contamination of people

    International Nuclear Information System (INIS)

    Rische, U.W.; Gerlach, R.

    1986-01-01

    The monitor has only two detector columns at an angle to one another and possibly divided in height, whose detectors are divided in the vertical direction in a middle range depending on a reference shape. The units formed by the subdivision equal the effect produced by the subdivision in approximation to the reference shape in evaluation. By including the detector columns divided into several detectors in height, a detector of about half the width is produced at a level above the threshold. Underarm boxes are provided at the outer edge of this detector, which are directed obliquely upwards. (orig./HP) [de

  5. Biological monitoring of environmental contaminants (plants). Executive summary

    Energy Technology Data Exchange (ETDEWEB)

    Burton, M.A.S.

    1986-01-01

    Knowledge of contaminant concentrations does not necessarily indicate their significance to plant populations and communities within ecosystems. Accumulation within plants facilitates analysis of contaminants which may be present at very low levels in the environment and may show the spatial distribution and changes in the level of contamination with time. Effects on species distribution within plant communities and visible injury to foliage may also be related to contamination. Species can be selected appropriate to the area and the contaminant to be monitored. Species used to investigate the input of contaminants from atmospheric deposition, for example, may differ from those used to assess transfer through food webs. Mosses and lichens have been particularly widely used in many countries to show distribution of metals and radionuclides on local and regional scales and of pesticide contamination. Visible injury to foliage of higher plant species may reflect atmospheric concentrations of gaseous pollutants and monitoring networks of transplanted sensitive species can provide information on contaminant levels on a regional scale. Changes in species composition, especially of lichens, have also been related to the degree of contamination.

  6. Proximal spectral sensing to monitor phytoremediation of metal - contaminated soils

    NARCIS (Netherlands)

    Rathod, P.H.; Rossiter, D.; Noomen, M.; van der Meer, F.D.

    2013-01-01

    Assessment of soil contamination and its long-term monitoring are necessary to evaluate the effectiveness of phytoremediation systems. Spectral sensing-based monitoring methods promise obvious benefits compared to field-based methods: lower cost, faster data acquisition and better spatio-temporal

  7. Improvement in QA protocol for TLD based personnel monitoring laboratory in last five year

    International Nuclear Information System (INIS)

    Rakesh, R.B.

    2018-01-01

    The Quality Assurance (QA) in Personnel monitoring (PM) is a tool to assess the performance of PM laboratories and reliability of dose estimation with respect to standards laid down by international agencies such as IAEA (ISO trumpet curve), IEC, ANSI etc. Reliable personal dose estimation is a basic requirement for radiation protection planning as well as decision making continuous improvement in radiation protection is inherent in radiation protection practices which is highly dependent on accuracy and reliability of the monitoring data. Experience based evolution of Quality control (QC) measures as well as Quality assurance (QA) protocol are two important aspects towards continuous improvement in accuracy and reliability of personnel monitoring results. The paper describes improvement in QC measures and QA protocols initiated during the last five years which led to improvement in the quality of PM services

  8. Present state of the monitoring for internal contamination at Tokai Research Establishment, Japan Atomic Energy Research Institute

    International Nuclear Information System (INIS)

    Akaishi, J.; Fukuda, H.; Mizushita, S.

    1980-01-01

    At Tokai Research Establishment, JAERI, over one thousand people work in hot areas such as reactors, accelerators, chemical laboratories and waste treatment plants. The monitoring for internal contamination of this personnel is presented. Routine and special monitoring are carried out. The object of the former is to check for the presence of significant contamination, and that of the latter is to estimate body burden and committed dose equivalent, if necessary. Heavy shield and shadow shield whole body counters, a low energy lung counter and a wound monitor are used to detect the internal contamination due to γ or chi ray emitters, and bioassay technique is used for α or β emitters and uranium. The results of the monitoring until now are presented. (H.K.)

  9. Modeling, Monitoring and Fault Diagnosis of Spacecraft Air Contaminants

    Science.gov (United States)

    Ramirez, W. Fred; Skliar, Mikhail; Narayan, Anand; Morgenthaler, George W.; Smith, Gerald J.

    1998-01-01

    Control of air contaminants is a crucial factor in the safety considerations of crewed space flight. Indoor air quality needs to be closely monitored during long range missions such as a Mars mission, and also on large complex space structures such as the International Space Station. This work mainly pertains to the detection and simulation of air contaminants in the space station, though much of the work is easily extended to buildings, and issues of ventilation systems. Here we propose a method with which to track the presence of contaminants using an accurate physical model, and also develop a robust procedure that would raise alarms when certain tolerance levels are exceeded. A part of this research concerns the modeling of air flow inside a spacecraft, and the consequent dispersal pattern of contaminants. Our objective is to also monitor the contaminants on-line, so we develop a state estimation procedure that makes use of the measurements from a sensor system and determines an optimal estimate of the contamination in the system as a function of time and space. The real-time optimal estimates in turn are used to detect faults in the system and also offer diagnoses as to their sources. This work is concerned with the monitoring of air contaminants aboard future generation spacecraft and seeks to satisfy NASA's requirements as outlined in their Strategic Plan document (Technology Development Requirements, 1996).

  10. Factors and strategies in the occupational monitoring of personnel in medical angiography

    International Nuclear Information System (INIS)

    Benedict, S.H.; Kleck, J.H.; McLaughlin, J.E.

    1988-01-01

    Angiographic procedures which include extensive fluoroscopy are among those which can produce the highest radiation exposure of hospital workers. The introduction of hemiaxial projections, and vascular fluoroscopic boost imaging methods has increased diagnostic accuracy, but it has also increased the physician's exposure to scattered radiation. Medical facilities in angiography and catheterization vary in regards to type of equipment and training of personnel. The health physicist for a facility is compelled to initiate a program to measure the potential exposure from a facility as well as assist in the training of personnel to minimize the exposure. Training of the medical personnel also includes techniques of exposure monitoring which for some individuals is more practically attained by utilization of a double badge program. This is especially important in the university setting where new residents and fellows are being introduced to the facility

  11. Personnel reliability impact on petrochemical facilities monitoring system's failure skipping probability

    Science.gov (United States)

    Kostyukov, V. N.; Naumenko, A. P.

    2017-08-01

    The paper dwells upon urgent issues of evaluating impact of actions conducted by complex technological systems operators on their safe operation considering application of condition monitoring systems for elements and sub-systems of petrochemical production facilities. The main task for the research is to distinguish factors and criteria of monitoring system properties description, which would allow to evaluate impact of errors made by personnel on operation of real-time condition monitoring and diagnostic systems for machinery of petrochemical facilities, and find and objective criteria for monitoring system class, considering a human factor. On the basis of real-time condition monitoring concepts of sudden failure skipping risk, static and dynamic error, monitoring systems, one may solve a task of evaluation of impact that personnel's qualification has on monitoring system operation in terms of error in personnel or operators' actions while receiving information from monitoring systems and operating a technological system. Operator is considered as a part of the technological system. Although, personnel's behavior is usually a combination of the following parameters: input signal - information perceiving, reaction - decision making, response - decision implementing. Based on several researches on behavior of nuclear powers station operators in USA, Italy and other countries, as well as on researches conducted by Russian scientists, required data on operator's reliability were selected for analysis of operator's behavior at technological facilities diagnostics and monitoring systems. The calculations revealed that for the monitoring system selected as an example, the failure skipping risk for the set values of static (less than 0.01) and dynamic (less than 0.001) errors considering all related factors of data on reliability of information perception, decision-making, and reaction fulfilled is 0.037, in case when all the facilities and error probability are under

  12. Study of nuclear tracks on different polycarbonate foils and their feasibility for use in personnel monitoring

    International Nuclear Information System (INIS)

    Jayalakshmi, V.; Rohatgi, Rupali; Sathian, Deepa; Marathe, P.K.; Nair, Sarala; Chourasiya, G.; Kannan, S.

    2009-01-01

    CR-39 (PDAC) a solid state nuclear track detector, is used as a routine personnel monitor. 1800 workers are being monitored quarterly for fast neutron using CR-39 foils. These foils procured from Pershore Mouldings, UK are very expensive and indigenous development will make the foils cost effective. The aim of this paper is to find a suitable alternative to the imported CR-39 foils for use in personnel monitoring. The foils from three different manufacturers have been compared with CR-39 foils from Pershore Moulding, UK, presently in use. Out of the three, only sample no 1 is promising. It has a background and sensitivity comparable with CR-39 presently used. The sample 2 is CR-39 being developed in India, has a relatively high background and poor sensitivity. Efforts are being made to improve the quality of this sample. The sample 3 was a poly carbonate from local manufacturer which produced very few tracks and the standard deviation of track counts was very large and hence not useful for personnel monitoring. (author)

  13. Contamination control by laundry monitor at NPP

    International Nuclear Information System (INIS)

    Singh, Vishwanath P.; Rana, P.K.; Lokeshwar Rao, S.; Managanvi, S.S.

    2010-01-01

    The operation of nuclear power reactor produces electricity as well as small quantity of radioactive waste as gaseous, liquid and solid. The waste contains radionuclides produced by fission and activation in reactor systems with wide spectrum of energy and half life. The long-lived nuclides Sr, Cs, Ba, Iodine and Co etc compared to short-lived are important in view of radiation protection. The radioactive contamination on the materials, human body or other places where it is undesirable is enormously harmful to workers at Nuclear Power Plant (NPP). The spread of radioactive from controlled areas is very complex problem for power reactor plant management

  14. A Coupled model for ERT monitoring of contaminated sites

    Science.gov (United States)

    Wang, Yuling; Zhang, Bo; Gong, Shulan; Xu, Ya

    2018-02-01

    The performance of electrical resistivity tomography (ERT) system is usually investigated using a fixed resistivity distribution model in numerical simulation study. In this paper, a method to construct a time-varying resistivity model by coupling water transport, solute transport and constant current field is proposed for ERT monitoring of contaminated sites. Using the proposed method, a monitoring model is constructed for a contaminated site with a pollution region on the surface and ERT monitoring results at different time is calculated by the finite element method. The results show that ERT monitoring profiles can effectively reflect the increase of the pollution area caused by the diffusion of pollutants, but the extent of the pollution is not exactly the same as the actual situation. The model can be extended to any other case and can be used to scheme design and results analysis for ERT monitoring.

  15. Considerations of selection suggested for internal contamination monitoring in Cuba

    International Nuclear Information System (INIS)

    Cruz S, R.; Lopez B, G.; Placeres V, C.; Arado L, J.; Jova S, L.

    1996-01-01

    A method for calculating effective risk of radionuclide intake and hypothetical annual dose that will receive a person who works with unsealed sources is proposed. Calculated committed dose equivalent and metabolic characteristic of radionuclides permit to select the type of monitoring 'in vivo' and/or 'in vitro'. The method was applied to 396 workers from 28 institutions, where 20 radionuclides in 124 different products for 266 applications are used. From this study 62% of the workers had to be monitored for internal contamination, meanly by 'in vitro' monitoring. In practices of Nuclear Medicine and other medical uses 75% of the workers had to be monitored. These results permitted to corroborate the criteria for internal contamination monitoring program carried out by Center for Hygiene and Radiation Protection and permitted to identify needs for control of radionuclides intakes. (authors).5 refs., 3 figs

  16. Atmospheric air contamination monitoring. Monitoring station ASS-500, GIG Katowice

    International Nuclear Information System (INIS)

    Michalik, B.

    1993-01-01

    The results obtained during the period of 1991-1993 in monitoring station ASS-500 working in Katowice have been presented. The concentration of 137 Cs, 226 Ra, 40 K, 7 Be and dustiness in atmospheric air have been shown. Some proposals about the modifications of monitoring station ASS-500 have been introduced. 3 figs, 5 tabs

  17. Use of cellulose nitrate plastic track detectors in neutron personnel monitoring

    International Nuclear Information System (INIS)

    Venkataraman, G.; Marathe, P.K.; Joshi, R.V.

    1975-01-01

    Cellulose nitrate, which is a sensitive plastic material wherein even proton tracks could be recorded, was studied with a view to using it for personnel neutron monitoring work. It was found that among the commercially available plastics, the colourless transparent Daicel 6000 variety having a thickness of 0.6mm is satisfactory form the point of view of track recognition. The material was exposed to thermal neutrons, fission neutrons, neutrons from an Am-Be source and to 14 MeV neutrons. As is to be expected, there is no thermal neutron sensitivity. The sensitivity to fast neutrons is less by a factor of two as compared to that of the NTA nuclear track emulsion. It was observed that the background tracks found in the plastic correspond to nearly 100 mrem of fast neutron dose equivalent. It is felt that at present cellulose nitrate is useful for monitoring personnel involved in nuclear criticality accidents. (author)

  18. PAMTRAK: A system to monitor high value objects and personnel in restricted areas

    International Nuclear Information System (INIS)

    Anspach, D.A.; Walters, B.G.; Anspach, J.P.; Crain, B. Jr.

    1996-01-01

    The US Department of Energy (DOE) uses sensitive or classified parts and material that must be protected and accounted for. The authors believe there is a need for an automated system that can help protect and monitor these parts and material. In response to this need Sandia National Laboratories (SNL) has developed a real-time personnel and material tracking system called PAMTRAK that has been installed at selected DOE facilities. PAMTRAK safeguards sensitive parts and material by tracking tags worn by personnel and by monitoring sensors attached to the parts or material. This paper describes the goals when designing PAMTRAK, the PAMTRAK system components, the current installations, and the benefits a site can expect when using PAMTRAK

  19. Personnel and working area monitoring at the Department of Nuclear Science, Universiti Kebangsaan Malaysia

    International Nuclear Information System (INIS)

    Amran Abd Majid; Muhamad Samudi Yasir; Che Rosli Che Mat

    1995-01-01

    Personnel (staff and student) and working area absorbed dose monitoring at the Department of Nuclear Science from 1984 until September 1993 is reported. Generally average absorbed dose received by the staff and working area were less than 0.5 and 2.0 mSv/yr respectively. The application of low activity of radioactive materials and complying the UKM (Universiti Kebangsaan Malaysia) and LPTA (AELB) - Atomic Energy Licensing Board regulations contributing to the low rate recorded. (author)

  20. Ten years experience with a large computerized TLD-personnel monitoring system

    International Nuclear Information System (INIS)

    Duftschmid, K.E.

    1986-01-01

    It is now ten years since our Institute for Radiation Protection has fully replaced its filmdosimetry service by a computerized automated TLD system. Presently more than 13000 radiation workers are monthly monitored by three automated TLD readers linked to the computer center. The paper describes system hardware and software and experience gained in long-term routine operation. In particular the introduction of the new ICRU quantities for personnel dosimetry in the existing TLD system is discussed. (Author)

  1. Workplace monitoring for radiation and contamination

    International Nuclear Information System (INIS)

    1995-01-01

    Ionizing radiations cannot be seen, felt or sensed by the human body in any way but excessive exposure to them may have adverse health effects. In order to avoid excessive exposure, appropriate and efficient radiation measuring instruments are needed. This Module explains the basic terminology associated with such measuring instruments and describes the principal types, their construction and typical applications in the workplace. It is important to ensure not only that monitoring is carried out where there is a potential radiation exposure but also that the monitoring instrument is appropriate to the task and that the user places correct interpretations on the results obtained. The Manual will be of most benefit if it forms part of more comprehensive training or is supplemented by the advice of a qualified expert in radiation protection. Some of the instrument tests and calibrations described in this Module require the services of a qualified expert

  2. Mobile Monitoring System for Nuclear Contamination Analysis

    International Nuclear Information System (INIS)

    Broide, A.; Sheinfeld, M.; Marcus, E.; Wengrowicz, U.; Tirosh, D.

    2002-01-01

    In case of a nuclear accident, it is essential to have extensive knowledge concerning the nature of the radioactive plume expansion, for further analysis. For this purpose a mobile monitoring system may provide important data about the plume characteristics. An advanced Mobile Monitoring System is under development at the Nuclear Research Center-Negev. The system is composed of a network of mobile stations, typically installed onboard vehicles, which transmit radiation measurements along with position information to a central station. The mobile network's communications infrastructure is based on Motorola Mobile Logic Unit devices, which are state-of-the-art reliable modems with an integrated Global Positioning System module. The radiation measurements received by the central station are transferred to a risk assessment program, which evaluates the expected hazards to the populated areas located in the estimated plume's expansion direction

  3. Blind test results - measure of incessant progress in personnel monitoring services at Kudankulam Nuclear Power Project

    International Nuclear Information System (INIS)

    Jashi, K.B.; Ashok Kumar, A.; Pandaram, P.

    2018-01-01

    Personnel Monitoring Services (PMS) at Thermoluminescent Dosimeter (TLD) laboratory, Kudankulam Nuclear Power Project (KKNPP) involve monitoring of about 1500 radiation workers of KKNPP for external radiation exposure on monthly basis. Quality assurance in PMS provides an overall estimate of accuracy which depends not only upon the dosimeter quality and reader performance but also on data interpretation, applicable software and the system. Therefore it measures the effectiveness of quality control mechanism. Blind test is an effective tool to check the performance of the processor without their knowledge during routine processing of the service cards

  4. Capacity training for the personnel of radiation monitoring in metal recycling

    International Nuclear Information System (INIS)

    Caveda Ramos, C.A.; Dominguez Ley, O.

    2013-01-01

    In this work it a course for training for the personnel involved in the radiation monitoring of metal recycling is presented. The contents were elaborated taken into account the IAEA recommendations for the development of capacity and training activities in radiological safety and in the Guide for the control of radioactive material in metal recycling. The program is divided in eleven parts and the duration time is two weeks. Among the main covered topics are the requirements for radiation monitoring in metal recycling; response to detection of radioactive material and effects of the ionizing radiation in man and environment

  5. Automation system for tritium contaminated surface monitoring

    International Nuclear Information System (INIS)

    Culcer, Mihai; Iliescu, Mariana; Curuia, Marian; Raceanu, Mircea; Enache, Adrian; Stefanescu, Ioan; Ducu, Catalin; Malinovschi, Viorel

    2005-01-01

    The low energy of betas makes tritium difficult to detect. However, there are several methods used in tritium detection, such as liquid scintillation and ionization chambers. Tritium on or near a surface can be also detected using proportional counter and, recently, solid state devices. The paper presents our results in the design and achievement of a surface tritium monitor using a PIN photodiode as a solid state charged particle detector to count betas emitted from the surface. That method allows continuous, real-time and non-destructively measuring of tritium. (authors)

  6. TLD personnel monitoring dose estimation- extending the upper limit of the dose range

    International Nuclear Information System (INIS)

    Popli, K.L.; Sathian, Deepa; Divakaran, T.; Massand, O.P.

    2001-01-01

    TLD personnel monitoring was introduced in the year 1975 in India and at present nearly 41,000 radiation workers are being monitored by 13 monitoring laboratories all over India. The BARC- TLD being used for personnel monitoring is based on CaSO 4 :Dy embedded in PTFE and semi-automatic TL reader using hot N 2 Gas for heating the dosimeters. This reader has the range to measure γ dose from ten μSv to 3 μSv and x-ray dose form 1 μ Sv to 0.3 Sv due to the higher sensitivity of CaSO 4 : Dy to lower energy photons (20keV-50 keV) generated by diagnostic x-ray units. The x-ray radiation workers are at present nearly 35% of the total radiation workers monitored and this number is expected to grow as more and more number of x-ray workers are covered under this service. The upper limit of the x-ray dose range of the instrument is 0.3 Sv, whereas in the past one year it has been observed that at least 25% of the total overexposures reported in case of x-ray workers have recorded the dose more than 0.3 Sv. This paper presents the technique developed to extend the upper limit of the range from 0.3 Sv to 1 Sv for x-rays and 10 Sv for γ rays

  7. Workplace monitoring for radiation and contamination

    International Nuclear Information System (INIS)

    2004-01-01

    Ionizing radiations cannot be seen, felt or sensed by the human body in any way but excessive exposure to them may have adverse health effects. Radiation measuring instruments are needed in order to detect the presence of such radiations and avoid excessive exposure. The use of appropriate and efficient instruments enables exposures to be controlled and the doses received to be kept as low as reasonably achievable. This Manual explains the basic terminology associated with such measuring instruments and describes the principal types, their construction and typical applications in the workplace. It is important to ensure not only that monitoring is carried out where there is a potential radiation exposure but also that the monitoring instrument is appropriate to the task and that the user places correct interpretations on the results obtained. The Manual will be of most benefit if it forms part of more comprehensive training or is supplemented by the advice of a qualified expert in radiation protection. Some of the instrument tests and calibrations described in this Manual require the services of a qualified expert

  8. Belted kingfishers as ecological monitors of contamination: A review

    International Nuclear Information System (INIS)

    Landrum, C.L.

    1993-03-01

    Aquatic systems serve as transport pathways and reservoirs for most of the contaminants known to be present on the Oak Ridge Reservation (ORR). Organisms that live in aquatic systems accumulate some of these contaminants from their food and directly from the water or sediment. A wide array of terrestrial organisms feeds on aquatic organisms and may accumulate contaminants from aquatic prey. The belted kingfisher (Ceryle alcyon) is a piscivorous and territorial avian species that may be a suitable monitor of contaminant accumulation at specific sites on the ORR. A kingfisher collected on White Oak Lake in 1991 had a 137 Cs concentration of 568 pCi/g in muscle tissue, which exceeds levels found in any other waterfowl collected from the lake. An investigation into the efficacy of using the kingfisher as an ecological indicator of aquatic contaminants on the ORR was initiated in late August 1992. The primary objective of this study was to acquire information concerning the ecology of the kingfisher to determine how the species could be used within the framework of the Biological Monitoring and Abatement Program at Oak Ridge National Laboratory (ORNL). A second important objective of the study was to examine the possible somatic and reproductive effects of polychlorinated biphenyls (PCBs), Hg, and various radioactive contaminants on piscivorous birds by reviewing pollution ecology studies conducted on those species

  9. Belted kingfishers as ecological monitors of contamination: A review

    Energy Technology Data Exchange (ETDEWEB)

    Landrum, C.L. [North Texas Univ., Denton, TX (United States). Dept. of Biology; Ashwood, T.L.; Cox, D.K. [Oak Ridge National Lab., TN (United States)

    1993-03-01

    Aquatic systems serve as transport pathways and reservoirs for most of the contaminants known to be present on the Oak Ridge Reservation (ORR). Organisms that live in aquatic systems accumulate some of these contaminants from their food and directly from the water or sediment. A wide array of terrestrial organisms feeds on aquatic organisms and may accumulate contaminants from aquatic prey. The belted kingfisher (Ceryle alcyon) is a piscivorous and territorial avian species that may be a suitable monitor of contaminant accumulation at specific sites on the ORR. A kingfisher collected on White Oak Lake in 1991 had a {sup 137}Cs concentration of 568 pCi/g in muscle tissue, which exceeds levels found in any other waterfowl collected from the lake. An investigation into the efficacy of using the kingfisher as an ecological indicator of aquatic contaminants on the ORR was initiated in late August 1992. The primary objective of this study was to acquire information concerning the ecology of the kingfisher to determine how the species could be used within the framework of the Biological Monitoring and Abatement Program at Oak Ridge National Laboratory (ORNL). A second important objective of the study was to examine the possible somatic and reproductive effects of polychlorinated biphenyls (PCBs), Hg, and various radioactive contaminants on piscivorous birds by reviewing pollution ecology studies conducted on those species.

  10. Wireless Sensor Network Based Subsurface Contaminant Plume Monitoring

    Science.gov (United States)

    2012-04-16

    Sensor Network (WSN) to monitor contaminant plume movement in naturally heterogeneous subsurface formations to advance the sensor networking based...time to assess the source and predict future plume behavior. This proof-of-concept research aimed at demonstrating the use of an intelligent Wireless

  11. Air contamination control as an element of state environmental monitoring

    International Nuclear Information System (INIS)

    Grabowski, D.

    1993-01-01

    The results of air contamination control on the base of gamma and beta radioactivity of aerosols collected on filters and in precipitation samples have been shown. The data have been gathered from 12 monitoring stations in Poland during 1993. No significant differences between actual results and those obtained in previous years have been noticed. 4 figs, 1 tab

  12. Contamination monitor as a nuclear stethoscope for community nuclear medicine

    International Nuclear Information System (INIS)

    Rehani, M.M.; Sharma, S.K.; Sharma, R.R.

    1979-01-01

    A portable contamination monitor has been modified for use as an in vivo counting probe. The evaluation by physical parameters and clinical studies shows its suitability for a variety of diagnostic studies. The correlation equations for thyroid uptake measurement have been worked out for whole range of values. Its use as a versatile nuclear stethoscope is envisaged. (author)

  13. Application of effective variance method for contamination monitor calibration

    International Nuclear Information System (INIS)

    Goncalez, O.L.; Freitas, I.S.M. de.

    1990-01-01

    In this report, the calibration of a thin window Geiger-Muller type monitor for alpha superficial contamination is presented. The calibration curve is obtained by the method of the least-squares fitting with effective variance. The method and the approach for the calculation are briefly discussed. (author)

  14. Thermoexoemission detectors for monitoring radioactive contamination of industrial waste waters

    International Nuclear Information System (INIS)

    Obukhov, V.T.; Sobolev, I.A.; Khomchik, L.M.

    1987-01-01

    Detectors on base of BeO(Na) monocrystals with thermoemission to be used for monitoring radioactive contamination of industrial waste waters are suggested. The detectors advantages are sensitivity to α and low-ehergy β radiations, high mechanical strength and wide range of measurements. The main disadvantage is the necessity of working in red light

  15. Monitoring bacterial faecal contamination in waters using multiplex ...

    African Journals Online (AJOL)

    Monitoring of sanitary quality or faecal pollution in water is currently based on quantifying some bacterial indicators such as Escherichia coli and faecal enterococci. Using a multiplex real-time PCR assay for faecal enterococci and Bacteroides spp., the detection of faecal contamination in non-treated water can be done in a ...

  16. Development of a calibration system for surface contamination monitors

    International Nuclear Information System (INIS)

    Marechal, M.H.H.; Barbosa, M.P.

    1992-01-01

    A calibration system for surface contamination monitors is developed, aiming supply the existence demand of these instruments. A experimental arrangement and a methodology are described. The advantages of use this system for calibration routine optimization are also discussed. (C.G.C.)

  17. Body-surface contamination monitoring preparatory to monitoring for internal contamination

    International Nuclear Information System (INIS)

    Schlueter, W.; Klucke, H.

    1980-01-01

    Measurements in the whole-body counter of the SAAS are routinely preceded by a thorough inspection of the patients for body-surface contamination to protect the sensitive counting equipment against becoming contaminated and to avoid a falsified indication of incorporated radionuclides. The measuring system employed for these examinations is described. (author)

  18. Monitoring of health care personnel employee and occupational health immunization program practices in the United States.

    Science.gov (United States)

    Carrico, Ruth M; Sorrells, Nikka; Westhusing, Kelly; Wiemken, Timothy

    2014-01-01

    Recent studies have identified concerns with various elements of health care personnel immunization programs, including the handling and management of the vaccine. The purpose of this study was to assess monitoring processes that support evaluation of the care of vaccines in health care settings. An 11-question survey instrument was developed for use in scripted telephone surveys. State health departments in all 50 states in the United States and the District of Columbia were the target audience for the surveys. Data from a total of 47 states were obtained and analyzed. No states reported an existing monitoring process for evaluation of health care personnel immunization programs in their states. Our assessment indicates that vaccine evaluation processes for health care facilities are rare to nonexistent in the United States. Identifying existing practice gaps and resultant opportunities for improvements may be an important safety initiative that protects patients and health care personnel. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  19. [Research on hyperspectral remote sensing in monitoring snow contamination concentration].

    Science.gov (United States)

    Tang, Xu-guang; Liu, Dian-wei; Zhang, Bai; Du, Jia; Lei, Xiao-chun; Zeng, Li-hong; Wang, Yuan-dong; Song, Kai-shan

    2011-05-01

    Contaminants in the snow can be used to reflect regional and global environmental pollution caused by human activities. However, so far, the research on space-time monitoring of snow contamination concentration for a wide range or areas difficult for human to reach is very scarce. In the present paper, based on the simulated atmospheric deposition experiments, the spectroscopy technique method was applied to analyze the effect of different contamination concentration on the snow reflectance spectra. Then an evaluation of snow contamination concentration (SCC) retrieval methods was conducted using characteristic index method (SDI), principal component analysis (PCA), BP neural network and RBF neural network method, and the estimate effects of four methods were compared. The results showed that the neural network model combined with hyperspectral remote sensing data could estimate the SCC well.

  20. Nuclear radiation monitoring instruments for personnel in nuclear disaster for defence needs

    International Nuclear Information System (INIS)

    Bhatnagar, P.K.; Vaijapurkar, S.G.; Yadav, Ashok

    2005-01-01

    Ever since the tragedy of nuclear device exploding over Japan by USA in 1945 awareness exists amongst the armed forces personnel all over the world that a requirement of implementing radiological protection is imminent. Towards this adoption of radiological safety programme is a criterion. In a nuclear war disaster scenario, one encounters initial nuclear radiation (gamma and neutron radiations), gamma radiations from fallout, heat and blast. At certain distances Tanks/ armoured vehicles will survive and 4 R/s radiation level sensing to actuate relays for closing the ports of vehicles is essential, leading to reduction in inhalation, ingestion of fallout radioactivity and reduction in radiation dose received by occupants of the vehicle. Towards this sturdy radiation monitors to indicate gamma dose rate of the order of 1000 R/h, gamma and neutron dosimeters of the order of 1000 cGy with reading instruments are to be developed. These must work in harsh environment and sustain JSS 55555 conditions of army. Defence Laboratory, Jodhpur over past one decade has been involved in developing personnel, area and field monitoring instruments like dosimeters, survey meters, which are useful, acceptable to army personnel, armoured and personnel carrier vehicles, field structures/shelters. Technology transfer after satisfaction of armed forces, product ionisation and supply, maintenance, training has been the endeavor of the DRDO. Herein it is proposed to highlight the techno electronics nuclear radiation monitoring sensors and associated electronics systems developed first time in the country and productionised in bulk for Services for implementing personnel protection. The sensors developed and described are - Radiophotoluminescent Glass (RPLG) for gamma radiation dosimetry , neutron sensitive PIN diode for fast neutron dosimetry, gamma radiation sensitive PIN diode, superheated liquid neutron and gamma sensors. The dosimeter, dose rate meter and field/area instruments are

  1. Internal exposure monitoring of personnel of a nuclear power plant with pressurized-water reactors

    International Nuclear Information System (INIS)

    Krueger, F.W.; Poulheim, K.F.; Rueger, G.; Schreiter, W.D.

    1982-01-01

    In the GDR a programme for monitoring the internal radiation exposure of personnel has been established in the Bruno Leuschner Nuclear Power Plant, Greifswald, which allows one to estimate the effective dose equivalent in the way recommended by the ICRP. The measuring equipment used, and the methods of calibration and of evaluation of results are described. At present about 400 persons are monthly monitored with a thorax monitor in the nuclear power plant. If an investigation level - corresponding to an effective dose equivalent of 0.3mSv/month - is exceeded, a more exact measurement is made in the whole-body counter at the National Board for Nuclear Safety and Radiation Protection of the GDR. In addition, a selected group of 50 persons is measured twice yearly in the whole-body counter. The measurements show the high effectiveness of the protective measures against radionuclide intake by workers in the nuclear power plant, resulting in a contribution of less than 1% to the collective dose of the personnel. A correlation has been found between external and internal exposure indicating that, in general, there will be a higher intake only under conditions resulting also in higher external exposures. The highest individual values of internal exposure found are below 0.5mSv/month and thus within the range of the lower detection limit of dosimeter films used for monitoring the external exposure. (author)

  2. Personnel monitoring- overexposure investigations and follow-up in non-DAE institutions during 1994-2003

    International Nuclear Information System (INIS)

    Mahajan, J.M.; Massand, O.P.

    2004-04-01

    Personnel Monitoring Section, Bhabha Atomic Research Centre, Mumbai, is entrusted with the responsibility of providing a countrywide personnel monitoring to radiation workers using external radiation like X, beta, gamma and neutron. As per Radiation Protection Rules (RPR) of 1971 promulgated by the competent authority the personnel monitoring service is mandatory for all the workers working with radiation. The radiation exposures received by them should be within the limits prescribed by AERB. For effective control of doses to the radiation workers the reporting, investigation and follow-up of overexposure cases play an important part in the countrywide personnel monitoring programme. Various aspects of overexposure investigations and follow-up as well as the analysis of overexposure doses recorded or received by the radiation workers during 1994 to 2003 are presented in this report. (author)

  3. An overview of existing raptor contaminant monitoring activities in Europe.

    Science.gov (United States)

    Gómez-Ramírez, P; Shore, R F; van den Brink, N W; van Hattum, B; Bustnes, J O; Duke, G; Fritsch, C; García-Fernández, A J; Helander, B O; Jaspers, V; Krone, O; Martínez-López, E; Mateo, R; Movalli, P; Sonne, C

    2014-06-01

    Biomonitoring using raptors as sentinels can provide early warning of the potential impacts of contaminants on humans and the environment and also a means of tracking the success of associated mitigation measures. Examples include detection of heavy metal-induced immune system impairment, PCB-induced altered reproductive impacts, and toxicity associated with lead in shot game. Authorisation of such releases and implementation of mitigation is now increasingly delivered through EU-wide directives but there is little established pan-European monitoring to quantify outcomes. We investigated the potential for EU-wide coordinated contaminant monitoring using raptors as sentinels. We did this using a questionnaire to ascertain the current scale of national activity across 44 European countries. According to this survey, there have been 52 different contaminant monitoring schemes with raptors over the last 50years. There were active schemes in 15 (predominantly western European) countries and 23 schemes have been running for >20years; most monitoring was conducted for >5years. Legacy persistent organic compounds (specifically organochlorine insecticides and PCBs), and metals/metalloids were monitored in most of the 15 countries. Fungicides, flame retardants and anticoagulant rodenticides were also relatively frequently monitored (each in at least 6 countries). Common buzzard (Buteo buteo), common kestrel (Falco tinnunculus), golden eagle (Aquila chrysaetos), white-tailed sea eagle (Haliaeetus albicilla), peregrine falcon (Falco peregrinus), tawny owl (Strix aluco) and barn owl (Tyto alba) were most commonly monitored (each in 6-10 countries). Feathers and eggs were most widely analysed although many schemes also analysed body tissues. Our study reveals an existing capability across multiple European countries for contaminant monitoring using raptors. However, coordination between existing schemes and expansion of monitoring into Eastern Europe is needed. This would enable

  4. Applicability of monitored natural attenuation at radioactively contaminated sites

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-01-15

    The IAEA attaches great importance to the dissemination of information that can assist Member States with the development, implementation, maintenance and continuous improvement of systems, programmes and activities that support a sustainable nuclear fuel cycle and nuclear applications, including managing the legacy of past practices and accidents. Hence, the IAEA has initiated a comprehensive programme of work covering all aspects of environmental remediation including: - Technical and non-technical factors influencing decision making in environmental remediation; - Site characterization techniques and strategies; - Assessment of remediation technologies; - Assessment of technical options for cleanup of contaminated media; - Post-restoration compliance monitoring; - Assessment of the costs of remediation measures. It has been observed that many measures to remove or contain contamination are inefficient below certain concentrations, in general costly, and of a limited lifetime compared with the half-lives of the radionuclides concerned. Dispersed low level contamination poses a particular challenge to those charged with its remediation. Economic considerations in many Member States also result in constraints being placed on resources available to deal with such contamination. Experience has also shown that many techniques are not efficient below certain concentration thresholds or may entail impacts on certain environmental compartments in addition to those due to the contamination itself. This includes doses received by workers on the remediation project. As a result, the concept of relying on geological media to retain contaminants and/or to 'flatten out' concentration/dose peaks is increasingly being discussed in a remediation context. Technical Reports Series No. 424 (Remediation of Sites with Dispersed Radioactive Contamination) examined a variety of technological options for remediating dispersed contamination and concluded that the approaches can be broadly

  5. Applicability of monitored natural attenuation at radioactively contaminated sites

    International Nuclear Information System (INIS)

    2006-01-01

    The IAEA attaches great importance to the dissemination of information that can assist Member States with the development, implementation, maintenance and continuous improvement of systems, programmes and activities that support a sustainable nuclear fuel cycle and nuclear applications, including managing the legacy of past practices and accidents. Hence, the IAEA has initiated a comprehensive programme of work covering all aspects of environmental remediation including: - Technical and non-technical factors influencing decision making in environmental remediation; - Site characterization techniques and strategies; - Assessment of remediation technologies; - Assessment of technical options for cleanup of contaminated media; - Post-restoration compliance monitoring; - Assessment of the costs of remediation measures. It has been observed that many measures to remove or contain contamination are inefficient below certain concentrations, in general costly, and of a limited lifetime compared with the half-lives of the radionuclides concerned. Dispersed low level contamination poses a particular challenge to those charged with its remediation. Economic considerations in many Member States also result in constraints being placed on resources available to deal with such contamination. Experience has also shown that many techniques are not efficient below certain concentration thresholds or may entail impacts on certain environmental compartments in addition to those due to the contamination itself. This includes doses received by workers on the remediation project. As a result, the concept of relying on geological media to retain contaminants and/or to 'flatten out' concentration/dose peaks is increasingly being discussed in a remediation context. Technical Reports Series No. 424 (Remediation of Sites with Dispersed Radioactive Contamination) examined a variety of technological options for remediating dispersed contamination and concluded that the approaches can be broadly

  6. Evaluation of sensitivity evaluation of a contamination monitor for use in monitoring of internal exposure of workers in nuclear medicine

    International Nuclear Information System (INIS)

    Dantas, Bernando Maranhao; Assis, Janima Cruz de; Oliveira, Salomao Marques de; Dantas, Ana Leticia Almeida

    2014-01-01

    In practice of nuclear medicine, expert personnel routinely handle radiopharmaceuticals for diagnosis and radiotherapy. The control of intakes of radionuclides by workers can be performed through internal dosimetry techniques, as an integral part of the radiation protection program of the installation. The use of radiopharmaceuticals for diagnostic and therapeutic purposes in vivo and in vitro in Brazil is regulated by CNEN-NE Standards and 3:05 CNEN-NN 3.01. The International Atomic Energy Agency (IAEA) recommends the establishment of an internal monitoring program on workers, especially those subject to possible exposure to annual effective doses greater than 1 mSv. Note that, currently, in Brazil, are not available qualified laboratories to provide internal monitoring services in all regions in the country, if it were applied by CNEN, the requirement for internal monitoring of workers. This paper presents the development of a simple and low-cost methodology for in vivo monitoring of 131 I in the thyroid. The proposed methodology is the use of portable monitor of surface contamination, equipment available and routinely used in all nuclear medicine services in Brazil. The monitor is calibrated with neck-thyroid simulator developed at the Laboratory of In Vivo Monitoring of IRD/CNEN-RJ. The equipment tested is suitable for application in in vivo occupational monitoring thyroid. This conclusion is based on the fact that the detection system has sufficient sensitivity for monitoring up to seven days after the incorporation of the radionuclide and guarantees 131 I detection in values that result in effective doses below 1 mSv for the exposure scenarios adopted

  7. Design and Development of Hand and Foot Contamination Monitor

    Directory of Open Access Journals (Sweden)

    F. Akter

    2014-08-01

    Full Text Available A hand and foot contamination monitor is a health physics instrument to provide detection and measurement of beta-gamma contamination on the palm of each hand and on the bottom surface of both feet/shoes. There are four channels of detection for two hands and two feet. Four G-M detectors have been used in a single unit to cover the whole area of hand and feet. A regulated high voltage DC power supply (900 V has been designed using the PIC12F675 microcontroller to operate the pancake Geiger-Müller detectors. The reading is displayed on a linearly scaled 0-100 Bq/cm2 analog panel meter. The monitor detects beta–gamma radiation emitted by radioactive materials, and if the detected value exceeds a preset level, the monitor sounds an alarm and displays a reading in the respective panel meter. Indicator lamps are used to show the status of contamination. The performance of the system has been tested by using pulse generator and by flat surface radioactive calibration sources. Electronic linearity, detection efficiency, response to the contamination, calibration factor and percentage of error has been measured. Test results were satisfactory and the present system can be used instead of similar imported instruments.

  8. Individual radiological monitoring for exposed personnel of Nuclear Fuel Plant at Pitesti

    International Nuclear Information System (INIS)

    Ivana, T.; Epure, Gh.

    2010-01-01

    In the activity of nuclear fuel fabrication of CANDU type, based on natural and depleted uranium, individual radiological monitoring of the personnel exposed to ionizing radiation is very carefully approached. For Nuclear Fuel Plant (NFP) facility, where uranium appears in bulk and itemized form, measures for individual radiological monitoring are established by Radiological Safety Manual (MSR) in accordance with national and international legislation. All NFP employees are classified in either category A or category B of exposure to ionizing radiation. The classification is a function of type of activity and magnitude of exposure. All the exposed personnel are monitored for external doses (from gamma radiation) by measuring the equivalent dose H p (10) with monthly frequency. The system used for external individual dosimetric monitoring is based on the thermoluminescent dosimeter (TLD) of PANASONIC type UD813AS14. The NFP incorporates an in-house dosimetric laboratory notified by Romanian regulatory body CNCAN (National Commission for Control of Nuclear Activities). The workers handling nuclear materials are exposed to internal intake of uranium, mainly by inhalation. For internal doses monitoring is included part of exposed employees working directly with radioactive open sources (pulverulent or liquid nuclear materials), UO 2 sinterable powder, green pellets, sintered pellets, scrap and radioactive effluents. The estimation of internal exposure is made quarterly using the results from radioactive airborne monitors operating in the working places. The internal dose of each person exposed to open sources is calculated taking into account the rate of breathing, the time spent at the work place and the dose-activity coefficient (variable function of uranium absorption rate). The total effective individual dose is obtained by summing the external dose and internal dose (E=E ext +E int ). For conformity, the total effective individual dose (E) is compared with dose

  9. Introducing 2D barcode on TLD cards - a step towards automation in personnel monitoring

    International Nuclear Information System (INIS)

    Ajoy, K.C.; Dhanasekaran, A.; Annalakshmi, O; Rajagopal, V.; Santhanam, R.; Jose, M.T.

    2018-01-01

    As part of personnel monitoring services, TLD lab, RSD, IGCAR issues and receives large numbers of TLD cards every month, for use by occupational workers belonging to various hot facilities at Kalpakkam. Considering the nature of the work being manual, routine, labour intensive and being prone for human errors, introducing automation would be necessary at the TLD lab as well as at the user facility. This requires identification of the individual components of the TLD and embed them with unique identification for the system to accomplish the task. The paper discusses the automation part related to the TLD cards

  10. Monitoring of tritium-contaminated surfaces, including skin

    Energy Technology Data Exchange (ETDEWEB)

    Surette, R A; Wood, M J

    1994-05-01

    We have examined various commercially available tritium surface contamination monitors along with different swipe media and techniques for direct and indirect (swipe) monitoring of contaminated surfaces, including skin. None of the methods or instruments evaluated were more sensitive than the swipe and liquid scintillation counting (LSC) method. Swipe measurements with open-window proportional counters were, in general, less than half as sensitive as LSC, but have the advantages of having the results available almost immediately, and no sample preparation is required. The Nuclear Measurement Corporation`s PC-55 is the most suitable instrument we tested for the analysis of routine swipe measurement. The PC-55 was about one third as sensitive as LSC when used with Ontario Hydro filter paper swipe media. Surface contamination measurement results can be obtained within minutes using the PC-55, compared to hours using LSC. The selection of swipe media for use with proportional counter-based instruments is critical. A medium that is electrically insulating can develop an electrostatic charge on its surface; this may alter the field gradient in the detector and may adversely influence the results. Although the PC-55 is sufficiently sensitive and very convenient, operational experience with the instrument is needed before recommending that it replace current LSC methods. The PC-55`s susceptibility to internal tritium contamination may limit its practical usefulness. Because of the complexity of using live animals to evaluate direct and indirect methods for assessing skin contamination, pig skin was investigated as a possible substitute. We concluded that, for the first few hours post-exposure, pig skin mimics the kinetics of animal skin that has contacted a tritium-contaminated surface. (author). 30 refs., 1 tab., 7 figs.

  11. Monitoring of tritium-contaminated surfaces, including skin

    International Nuclear Information System (INIS)

    Surette, R.A.; Wood, M.J.

    1994-05-01

    We have examined various commercially available tritium surface contamination monitors along with different swipe media and techniques for direct and indirect (swipe) monitoring of contaminated surfaces, including skin. None of the methods or instruments evaluated were more sensitive than the swipe and liquid scintillation counting (LSC) method. Swipe measurements with open-window proportional counters were, in general, less than half as sensitive as LSC, but have the advantages of having the results available almost immediately, and no sample preparation is required. The Nuclear Measurement Corporation's PC-55 is the most suitable instrument we tested for the analysis of routine swipe measurement. The PC-55 was about one third as sensitive as LSC when used with Ontario Hydro filter paper swipe media. Surface contamination measurement results can be obtained within minutes using the PC-55, compared to hours using LSC. The selection of swipe media for use with proportional counter-based instruments is critical. A medium that is electrically insulating can develop an electrostatic charge on its surface; this may alter the field gradient in the detector and may adversely influence the results. Although the PC-55 is sufficiently sensitive and very convenient, operational experience with the instrument is needed before recommending that it replace current LSC methods. The PC-55's susceptibility to internal tritium contamination may limit its practical usefulness. Because of the complexity of using live animals to evaluate direct and indirect methods for assessing skin contamination, pig skin was investigated as a possible substitute. We concluded that, for the first few hours post-exposure, pig skin mimics the kinetics of animal skin that has contacted a tritium-contaminated surface. (author). 30 refs., 1 tab., 7 figs

  12. A portable contamination monitor with a numerical display

    International Nuclear Information System (INIS)

    Jones, A.R.

    1980-10-01

    A portable contamination monitor, its performance and application are described. The monitor is equipped with two 15.5 cm 2 'pancake' type Geiger-Mueller counters with thin windows ( 2 ). The summed counting rate is displayed in the range 0.2000 counts/s on a liquid crystal digital voltmeter. Every tenth pulse is signaled by flashing an LED and emitting a short (0.1 s) pulse of sound. The efficiencies for detecting a variety of α-, β- and γ- emitters have been measured and are reported. Data on the effects of varying battery voltage and temperature are also reported. (auth)

  13. A practical approach towards minimisation of latent image fading in personnel monitoring films

    International Nuclear Information System (INIS)

    Dhond, R.V.; Patel, P.H.; Shenoy, K.S.; Adtani, M.M.

    1980-01-01

    A serious drawback of the film badges used in personnel monitoring is the latent image fading often as high as 95% when they are subjected to extreme climatic conditions such as high humidities and temperatures. Current data on latent image fading in personnel monitoring films of various brands of manufacturers (Kodak, Agfa-Gevaert, Du Pont) are summarized. If individual film packs are hermitically sealed in polythene envelopes, fading is reduced to 20%. Studies were, therefore, conducted on Kodak type 2 films to observe the radiation response of films subjected alternatively to humid (20deg C and 90% r.h.) conditions for 8 hours and dry (20deg C and 30 to 40% r.h.) conditions for 16 hours with a view to find out a practicable and simple method to minimise the error due to fading. The films were then exposed to 600, 1200, 2400 and 4800 mR of radium-226 gammas after one week of storage and replaced in their experimental conditions. The films were processed after zero, one and two weeks of their storage in their respective conditions. Dose versus density curves of films were plotted. A fading less than 10% is shown for a storage period of two weeks. It is also suggested that films be kept in a desiccator having dry silica gel crystals during the periods when they are not being worn by the radiation workers. (M.G.B.)

  14. Development of a real-time extremity dose monitor for personnel in interventional radiology

    International Nuclear Information System (INIS)

    Ban, Nobuhiko; Kusama, Tomoko; Adachi, Akiko

    2000-01-01

    Protection of personnel in interventional radiology is one of the most important issues of radiological protection in medicine. Fluoroscopically guided interventional procedures require the operation near X-ray beam, which brings a considerable hand exposure to the operators. For the purpose of effectual control of their extremity doses, we have developed a real-time extremity dose monitor which is worn on a strap around the wrist. The monitor consists of a silicon semiconductor detector, thin lithium battery and a waterproof frame with a four-digit LED display. Experiment was carried out to examine a response of the monitor to diagnostic X-rays. A practical test was also performed to evaluate usability in the actual interventional procedures. In the experiment, the extremity dose monitor was placed on an arm phantom and exposed to diagnostic X-rays. Readings of the monitor were compared to those of Capintec PS-033 shallow chamber. The monitor was highly sensitive to diagnostic X-rays. It showed a linear response down to doses of a few tens of microsieverts. For high dose-rate exposure, however, a slight decrease in the response was observed, about 10% of counting loss for 80 kV, 40 mA X-ray at one meter from the focus. With regard to energy dependence, variation was within 20% for 60 to 100 kV X-rays. The monitor showed a good angular response in general, except lateral geometry facing the far side from a detector center. In the practical test, hand exposures of medical staff were measured with the extremity dose monitor. They were also asked to fill in a questionnaire regarding size and weight of the monitor, clarity of the display and usefulness. The subjects consisted of physicians, technicians and nurses who engaged in angiography, PTCD, CT-biopsy, barium enema and so on. The readings of the monitor were less than 1 mSv in most cases while 93 mSv was recorded in an extreme case due to direct-beam exposure. In some cases, TLD rings were used together with the

  15. Development of a real-time extremity dose monitor for personnel in interventional radiology

    Energy Technology Data Exchange (ETDEWEB)

    Ban, Nobuhiko; Kusama, Tomoko [Oita University of Nursing and Health Sciences, Oita (Japan); Adachi, Akiko [Oita Medical University, Oita (JP)] [and others

    2000-05-01

    Protection of personnel in interventional radiology is one of the most important issues of radiological protection in medicine. Fluoroscopically guided interventional procedures require the operation near X-ray beam, which brings a considerable hand exposure to the operators. For the purpose of effectual control of their extremity doses, we have developed a real-time extremity dose monitor which is worn on a strap around the wrist. The monitor consists of a silicon semiconductor detector, thin lithium battery and a waterproof frame with a four-digit LED display. Experiment was carried out to examine a response of the monitor to diagnostic X-rays. A practical test was also performed to evaluate usability in the actual interventional procedures. In the experiment, the extremity dose monitor was placed on an arm phantom and exposed to diagnostic X-rays. Readings of the monitor were compared to those of Capintec PS-033 shallow chamber. The monitor was highly sensitive to diagnostic X-rays. It showed a linear response down to doses of a few tens of microsieverts. For high dose-rate exposure, however, a slight decrease in the response was observed, about 10% of counting loss for 80 kV, 40 mA X-ray at one meter from the focus. With regard to energy dependence, variation was within 20% for 60 to 100 kV X-rays. The monitor showed a good angular response in general, except lateral geometry facing the far side from a detector center. In the practical test, hand exposures of medical staff were measured with the extremity dose monitor. They were also asked to fill in a questionnaire regarding size and weight of the monitor, clarity of the display and usefulness. The subjects consisted of physicians, technicians and nurses who engaged in angiography, PTCD, CT-biopsy, barium enema and so on. The readings of the monitor were less than 1 mSv in most cases while 93 mSv was recorded in an extreme case due to direct-beam exposure. In some cases, TLD rings were used together with the

  16. Film badge personnel monitoring and dose distribution of industrial and medical workers in the country (1994-1998)

    International Nuclear Information System (INIS)

    Mittal, Hariom; Pandey, R.L.; Massand, O.P.

    2001-03-01

    Personnel Monitoring Section, Bhabha Atomic Research Centre, Mumbai, is entrusted with the responsibility of providing a countrywide personnel monitoring to radiation workers using extemal radiation like X, beta, gamma and neutron. As per Radiation Protection Rules (RPR) of 1971 promulgated by the competent authority the personnel monitoring service is mandatory for all the workers working with radiation. The radiation exposures received by them should be within the limits stipulated by AERB. Nearly 43,000 radiation workers in about 3000 DAE and non DAE institutions using radiation and radioisotopes are monitored, using both the Film Badges and the Thermoluminescent dosimeters. This report presents various aspects of film dosimetry which was introduced more than four decades ago in the country and also analysis of doses received by the radiation workers in the five year block 1994-1998 covered by film badge service. (author)

  17. Evaluation of surface contamination due to alpha using large area contamination monitors

    International Nuclear Information System (INIS)

    Raghavayya, M.

    1998-01-01

    Radioactive contamination at work places is evaluated routinely using either the swipe sampling technique or a contamination monitor. Commercially available alpha probes used for the purpose are usually circular and have a face diameter of 50 or 100 mm. Square faced probes are also available. A thin aluminized mylar membrane of thickness 0.45 to 0.9 mg.cm -2 is used to screen the phosphor in the alpha probe to protect it from external light. The membrane cuts off more alphas from low energy emitters than from higher energy alpha emitters. Moreover the response of the detector for alphas originating at all points under the detector face is not uniform, especially when the large area alpha monitors are used. These factors can introduce errors as high as 40% into the measurements. This paper aims to quantify these errors and describe a procedure to overcome the limitations. (author)

  18. Optimisation of internal contamination monitoring programme by integration of uncertainties

    International Nuclear Information System (INIS)

    Davesne, E.; Casanova, P.; Chojnacki, E.; Paquet, F.; Blanchardon, E.

    2011-01-01

    Potential internal contamination of workers is monitored by periodic bioassay measurements interpreted in terms of intake and committed effective dose by the use of biokinetic and dosimetric models. After a prospective evaluation of exposure at a workplace, a suitable monitoring programme can be defined by choosing adequate measurement techniques and frequency. In this study, the sensitivity of a programme is evaluated by the minimum intake and dose, which may be detected with a given level of confidence by taking into account uncertainties on exposure conditions and measurements. This is made for programme optimisation, which is performed by comparing the sensitivities of different alternative programmes. These methods were applied at the AREVA NC reprocessing plant and support the current monitoring programme as the best compromise between the cost of the measurements and the sensitivity of the programme. (authors)

  19. Eye lens monitoring for interventional radiology personnel: dosemeters, calibration and practical aspects of Hp(3) monitoring. A 2015 review

    International Nuclear Information System (INIS)

    Carinou, Eleftheria; Ferrari, Paolo; Bjelac, Olivera Ciraj; Gingaume, Merce; Merce, Marta Sans; O’Connor, Una

    2015-01-01

    A thorough literature review about the current situation on the implementation of eye lens monitoring has been performed in order to provide recommendations regarding dosemeter types, calibration procedures and practical aspects of eye lens monitoring for interventional radiology personnel. Most relevant data and recommendations from about 100 papers have been analysed and classified in the following topics: challenges of today in eye lens monitoring; conversion coefficients, phantoms and calibration procedures for eye lens dose evaluation; correction factors and dosemeters for eye lens dose measurements; dosemeter position and influence of protective devices. The major findings of the review can be summarised as follows: the recommended operational quantity for the eye lens monitoring is H p (3). At present, several dosemeters are available for eye lens monitoring and calibration procedures are being developed. However, in practice, very often, alternative methods are used to assess the dose to the eye lens. A summary of correction factors found in the literature for the assessment of the eye lens dose is provided. These factors can give an estimation of the eye lens dose when alternative methods, such as the use of a whole body dosemeter, are used. A wide range of values is found, thus indicating the large uncertainty associated with these simplified methods. Reduction factors from most common protective devices obtained experimentally and using Monte Carlo calculations are presented. The paper concludes that the use of a dosemeter placed at collar level outside the lead apron can provide a useful first estimate of the eye lens exposure. However, for workplaces with estimated annual equivalent dose to the eye lens close to the dose limit, specific eye lens monitoring should be performed. Finally, training of the involved medical staff on the risks of ionising radiation for the eye lens and on the correct use of protective systems is strongly recommended. (review)

  20. X-ray and γ-radiation personnel monitoring by means of ionization chambers

    International Nuclear Information System (INIS)

    Gavrilovskij, L.P.; Nikitin, V.I.

    1981-01-01

    Several sets of condensator ionization chambers for measuring a dose of short-wave X-ray and gamma radiations within the limits of 0.005-50 R is described in short. In particular the following sets for personnel monitoring are described: the KID-2 set intended for determining an exposure dose of roentgen and gamma radiations of 150 keV - 2 MeV energy within the limits of 0.005-1R; the DK-02 set providing the measurement of personnel exposure doses of X-ray and gamma radiations within the limits of 0.02-200 mR in the energy range of 100 keV-2 MeV; the DP-22 V, DP-24 sets providing the measurement of an exposure dose of X-ray and gamma radiations within the limits of 1-50 R at a power of 0.5-200 R/h in the energy range of 0.1-2 MeV. An order of work with the sets is described [ru

  1. Rapid monitoring for transuranic contaminants during buried waste retrieval

    International Nuclear Information System (INIS)

    McIsaac, C.V.; Sill, C.W.; Gehrke, R.J.; Shaw, P.G.; Randolph, P.D.; Amaro, C.R.; Pawelko, R.J.; Thompson, D.N.; Loomis, G.G.

    1991-03-01

    This document reports results of research performed in support of possible future transuranic waste retrieval operations at the Idaho National Engineering Laboratory Radioactive Waste Management Complex. The focus of this research was to evaluate various methods of performing rapid and, as much as possible, ''on-line'' quantitative measurements of 239 Pu or 241 Am, either as airborne or loose contamination. Four different alpha continuous air monitors were evaluated for lower levels of detection of airborne 239 Pu. All of the continuous air monitors were evaluated by sampling ambient air. In addition, three of the continuous air monitors were evaluated by sampling air synthetically laden with clean dust and dust spiked with 239 Pu. Six methods for making quantitative measurements of loose contamination were investigated. They were: (1) microwave digestion followed by counting in a photon electron rejecting alpha liquid scintillation spectrometer, (2) rapid radiochemical separation followed by alpha spectrometry, (3) measurement of the 241 Am 59 keV gamma ray using a thin window germanium detector, (4) measurement of uranium L-shell x-rays, (5) gross alpha counting using a large-area Ag activated ZnS scintillator, and (6) direct counting of alpha particles using a large-area ionization chamber. 40 refs., 42 figs., 24 tabs

  2. Contaminant monitoring of hydraulic systems. The need for reliable data

    Energy Technology Data Exchange (ETDEWEB)

    Day, M.J. Rinkinen, J. [Pall Europe Ltd., Portsmouth (United Kingdom); Tampere University of Technology, Tampere (Finland)

    1998-12-31

    The need for both reliable operation of hydraulic and lubrication systems and long component lives has focused users to the benefits of controlling the contamination in the hydraulic fluid. Maximum operating (target) levels are being implemented as part of a condition based maintenance regime. If these are exceeded, maintenance effort is directed to correcting the rise in consummation level, and so make optimum use of resources as maintenance effort is only affected when it is necessary to do so. Fundamental to ibis aspect of condition based monitoring is the provision of accurate and reliable data in the shortest possible time. This way, corrective actions can be implemented immediately so minimising the damage to components. On-line monitoring devices are a way of achieving this and are seeing increased use, but some are affected by the condition of the fluid. Hence, there is a potential for giving incorrect data which will waste time and effort by initiating unnecessary corrective actions. A more disturbing aspect is the effect on the user of continual errors. The most likely effect would be a loss of confidence in the technique or even complete rejection of it and hence the potential benefits will be lost. This presentation explains how contaminant monitoring techniques are applied to ensure that the potential benefits of operating with clean fluids is realised. It examines the sources of error and shows how the user can interrogate the data and satisfy himself of its authenticity. (orig.) 14 refs.

  3. Contaminant monitoring of hydraulic systems. The need for reliable data

    Energy Technology Data Exchange (ETDEWEB)

    Day, M.J. [Pall Europe Ltd., Portsmouth (United Kingdom)] Rinkinen, J. [Tampere University of Technology, Tampere (Finland)

    1997-12-31

    The need for both reliable operation of hydraulic and lubrication systems and long component lives has focused users to the benefits of controlling the contamination in the hydraulic fluid. Maximum operating (target) levels are being implemented as part of a condition based maintenance regime. If these are exceeded, maintenance effort is directed to correcting the rise in consummation level, and so make optimum use of resources as maintenance effort is only affected when it is necessary to do so. Fundamental to ibis aspect of condition based monitoring is the provision of accurate and reliable data in the shortest possible time. This way, corrective actions can be implemented immediately so minimising the damage to components. On-line monitoring devices are a way of achieving this and are seeing increased use, but some are affected by the condition of the fluid. Hence, there is a potential for giving incorrect data which will waste time and effort by initiating unnecessary corrective actions. A more disturbing aspect is the effect on the user of continual errors. The most likely effect would be a loss of confidence in the technique or even complete rejection of it and hence the potential benefits will be lost. This presentation explains how contaminant monitoring techniques are applied to ensure that the potential benefits of operating with clean fluids is realised. It examines the sources of error and shows how the user can interrogate the data and satisfy himself of its authenticity. (orig.) 14 refs.

  4. Evaluation of two methods of rapid blood-glucose monitoring by unskilled personnel during surgery

    DEFF Research Database (Denmark)

    Madsbad, S; Adelhøj, B; Bigler, Dennis Richard

    1984-01-01

    The accuracy of two rapid methods of blood-glucose monitoring without (Haemo-glucotest 1-44) and with a reflectance meter (Hypocount B) was compared using a laboratory method. The assessment was carried out by personnel with no previous experience in measuring blood glucose. Eighty-five percent...... of the 92 measurements obtained with the hypocount B were within +/- 20% of the laboratory glucose values. Using haemo-glucotest 1-44 strips, 74% of the readings were within +/- 20% of the reference laboratory values. For values below 5.5 mmol/l, there was a tendency for results to be too low, with 77......% of the readings below laboratory values -20%. All situations with severe hypoglycaemia were detected with both strips. The study also demonstrates the ineffectiveness of s.c. insulin regimens during surgery. Only 47% of the measured blood glucose values were within the range of 5.5-10 mmol/l and two of ten...

  5. Development of a Real-time Hand Dose Monitor for Personnel in Interventional Radiology

    Energy Technology Data Exchange (ETDEWEB)

    Ban, N.; Nakaoka, H.; Haruta, R.; Murakami, Y.; Kubo, T.; Maeda, T.; Kusama, T

    2001-07-01

    Medical procedures denoted as interventional radiology require operation near an X ray beam, which brings high dose exposures to the operators' hands. For the effectual control of their extremity doses, a prototype of a real-time wrist dosemeter has been developed, hand dose monitor (HDM), based on a single silicon detector. Experiments were performed to test its response to diagnostic X rays. The HDM was highly sensitive and showed a linear response down to doses of a few tens of microsieverts. Though dose rate, energy and angular dependence of the response were observed in some extreme conditions, the HDM was proved to be of practical use if it was appropriately calibrated. Since an HDM enables personnel to check their hand doses on a real-time basis, it would enable medical staff to control the exposure themselves. (author)

  6. Dosimetry in mixed (n,gamma) fields in relation to personnel monitoring

    International Nuclear Information System (INIS)

    Nikodemova, D.; Hrabovcova, A.; Kubu, M.

    1987-01-01

    Neutron spectra were determined using neutron detection with a set of moderating spheres and the SAND computer method. A 6 LiI crystal or a pair of 6 LiF- 7 LiF thermoluminescence detectors was placed in the centre of 7 moderating spheres of 5 to 30 cm in diameter. 252 Cf and 241 Am-Be source were used in the calibration of the multisphere spectrometer. Neutron scattering from the walls, floor and ceiling was taken into consideration. The contribution of scattered neutrons was also determined for the case of measuring the 241 Am-Be spectrum with the source placed behind a water wall 10 cm thick. It is shown how the neutron energy distribution and the values of dose quantities altered as a result of the presence of scattered neutrons. The result of the presence of scattered neutrons. The results are discussed with respect to personnel monitoring. (author)

  7. Adequacy of annealing duration in reducing the background counts of personnel monitoring TLD cards - a study

    International Nuclear Information System (INIS)

    Srivastava, Kshama; Varadharajan, Geetha; Punekar, M.P.; Chougaokar, M.P.; Ayappan, P.

    2010-01-01

    In India, the personnel monitoring service of ∼ 70,000 radiation workers is being provided using indigenously developed TLD system comprising three CaSO 4 :Dy embedded Teflon discs. In order to remove TL and reset the distribution of defects/trapping centres, all TLD cards are subjected to an annealing treatment at elevated temperature prior to their next use. As per the standardized protocol annealing is carried out in a hot air circulating oven at 230 deg C for 4 hr, which is sufficient to reset the TL dosemeters for dose levels upto 100 mSv. In order to verify the appropriateness of annealing procedures adopted by the Laboratory, a detailed study was conducted using four sets of cards namely A, B, C and D series, exposed to various dose levels

  8. Occupational radiation exposure in Austria - results of personnel monitoring using thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Duftschmid, K.E.

    1979-01-01

    The Institut fuer Strahlenschutz, Seibersdorf, can look back on more than two years of experience with the automated TLD personnel monitoring system for routine control and dose record keeping of currently about 10.000 persons per month. For more than 100.000 entries on monthly received doses have been stored so far in the Master File of the Institute's computer centre. This paper presents a survey of the statistical dose distribution in the various sectors of employment such as industry, research establishments, medical establishments and nuclear facilities, including data on the mean annual doses and the collective doses for the various sectors; information is also given on the number of cases where a dose has been in excess of the set level, and on the measured data. The data stored in the dose record keeping system allow a detailed assessment to be made of the occupational radiation exposure in Austria. (orig.) [de

  9. Radioactive contamination in monitors received for calibration; Contaminacao em monitores de radiacao recebidos para calibracao

    Energy Technology Data Exchange (ETDEWEB)

    Dias, Paulo S.; Santos, Gilvan C. dos; Brunelo, Maria Antonieta G.; Paula, Tiago C. de; Pires, Marina A.; Borges, Jose C. [MRA Comercio de Instrumentos Eletronicos Ltda., Jardinopolis, SP (Brazil). Centro de Ensaios e Pesquisas em Metrologia (METROBRAS)

    2013-10-01

    The Calibration Laboratory - LABCAL, from the Research Center for Metrology and Testing - METROBRAS, MRA Comercio de Instrumentos Eletronicos Ltda., began activities in October 2008 and, in August 2009, decided to establish a procedure for monitoring tests, external and internal, of all packages received from customers, containing instruments for calibration. The aim was to investigate possible contamination radioactive on these instruments. On July 2011, this procedure was extended to packagings of personal thermoluminescent dosemeters - TLD, received by the newly created Laboratory Laboratorio de Dosimetria Pessoal - LDP . In the monitoring procedure were used monitors with external probe, type pancake, MRA brand, models GP - 500 and MIR 7028. During the 37 months in which this investigation was conducted, were detected 42 cases of radioactive contamination, with the following characteristics: 1) just one case was personal dosimeter, TLD type; 2) just one case was not from a packing from nuclear medicine service - was from a mining company; 3) contamination occurred on packs and instruments, located and/or widespread; 4) contamination values ranged from slightly above the level of background radiation to about a thousand fold. Although METROBRAS has facilities for decontamination, in most cases, especially those of higher contamination, the procedure followed was to store the contaminated material in a room used for storage of radioactive sources. Periodically, each package and/or instrument was monitored, being released when the radiation level matched the background radiation. Every contamination detected, the client and/or owner of the instrument was informed. The Brazilian National Energy Commission - CNEN, was informed, during your public consultation for reviewing the standard for nuclear medicine services, held in mid-2012, having received from METROBRAS the statistical data available at the time. The high frequency of contamination detected and the high

  10. PRD3000: A novel Personnel Radiation Detector with Radiation Exposure Monitoring

    International Nuclear Information System (INIS)

    Fallu-Labruyere, A.; Micou, C.; Schulcz, F.; Fellinger, J.

    2015-01-01

    PRD3000 TM is a novel Personal Radiation Detector (PRD) with personnel radiation dose exposure monitoring. It is intended for First Responders, Law Enforcement, Customs Inspectors protecting critical infrastructures for detecting unexpected radioactive sources, who also need real time Hp(10) dose equivalent information. Traditional PRD devices use scintillator materials instrumented through either a photomultiplier tube or a photodiode photodetector. While the former is bulky and sensitive to magnetic fields, the latter has to compromise radiation sensitivity and energy threshold given its current noise per unit of photo-detection surface. Recently, solid state photodetectors (SiPM), based on arrays of Geiger operated diodes, have emerged as a scalable digital photodetector for photon counting. Their strong breakdown voltage temperature dependence (on the order of tens of milli-volts per K) has however limited their use for portable instruments where strong temperature gradients can be experienced, and limited power is available to temperature stabilize. The PRD3000 is based on the industry standard DMC3000 active dosimeter that complies with IEC 61526 Ed. 3 and ANSI 42.20 for direct reading personal dose equivalent meters and active personnel radiation monitors. An extension module is based on a CsI(Tl) scintillator readout by a temperature compensated SiPM. Preliminary nuclear tests combined with a measured continuous operation in excess of 240 hours from a single AAA battery cell indicate that the PRD3000 complies with the IEC 62401 Ed.2 and ANSI 42.32 without sacrificing battery life time. We present a summary of the device test results, starting with performance stability over a temperature range of - 20 deg. C to 50 deg. C, false alarm rates and dynamic response time. (authors)

  11. PRD3000: A novel Personnel Radiation Detector with Radiation Exposure Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Fallu-Labruyere, A.; Micou, C.; Schulcz, F.; Fellinger, J. [Mirion Technologies - MGPI SA (France)

    2015-07-01

    PRD3000{sup TM} is a novel Personal Radiation Detector (PRD) with personnel radiation dose exposure monitoring. It is intended for First Responders, Law Enforcement, Customs Inspectors protecting critical infrastructures for detecting unexpected radioactive sources, who also need real time Hp(10) dose equivalent information. Traditional PRD devices use scintillator materials instrumented through either a photomultiplier tube or a photodiode photodetector. While the former is bulky and sensitive to magnetic fields, the latter has to compromise radiation sensitivity and energy threshold given its current noise per unit of photo-detection surface. Recently, solid state photodetectors (SiPM), based on arrays of Geiger operated diodes, have emerged as a scalable digital photodetector for photon counting. Their strong breakdown voltage temperature dependence (on the order of tens of milli-volts per K) has however limited their use for portable instruments where strong temperature gradients can be experienced, and limited power is available to temperature stabilize. The PRD3000 is based on the industry standard DMC3000 active dosimeter that complies with IEC 61526 Ed. 3 and ANSI 42.20 for direct reading personal dose equivalent meters and active personnel radiation monitors. An extension module is based on a CsI(Tl) scintillator readout by a temperature compensated SiPM. Preliminary nuclear tests combined with a measured continuous operation in excess of 240 hours from a single AAA battery cell indicate that the PRD3000 complies with the IEC 62401 Ed.2 and ANSI 42.32 without sacrificing battery life time. We present a summary of the device test results, starting with performance stability over a temperature range of - 20 deg. C to 50 deg. C, false alarm rates and dynamic response time. (authors)

  12. Acute care of radioactively contaminated or externally radiated personnel at nuclear power plants

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    Practical advice is given concerning the treatment of persons injure at nuclear power plant accidents, in particular accidents resulting in contamination or external radiation of man. The folder is primarily directed to persons responsible for the local plannning and supervision of emergency care at the power plant. (L.E.)

  13. Monitoring of raptors and their contamination levels in Norway.

    Science.gov (United States)

    Gjershaug, Jan Ove; Kålås, John Atle; Nygård, Torgeir; Herzke, Dorte; Folkestad, Alv Ottar

    2008-09-01

    This article summarizes results from raptor monitoring and contamination studies in Norway of the golden eagle, gyrfalcon, white-tailed sea eagle, osprey, peregrine, and merlin. Golden eagle and gyrfalcon populations have been monitored since 1990 as part of the "Monitoring Programme for Terrestrial Ecosystems" (TOV). No long-term trend in the population size or productivity of golden eagle has been shown in any of the 5 study areas. The reproductive output of gyrfalcon is monitored in 3 areas. It is positively correlated with the populations of its main prey species, the rock ptarmigan and the willow ptarmigan. The white-tailed sea eagle population has been monitored since 1974 by the Norwegian Ornithological Society, and the population is increasing. The levels of pesticides and polychlorinated biphenyls are low in the eggs of both the golden eagle and the gyrfalcon, but elevated levels and effects on reproduction have been indicated for a coastal subpopulation of golden eagle. The pollutant levels in white-tailed sea eagle are lower than in the Baltic population of sea eagles, and shell thinning was never severe overall, but individual eggs have contained pollutant concentrations above critical levels. The levels of pollutants in the bird-eating falcons, peregrine, and merlin were higher than in other species. New emerging pollutants, like brominated diphenylethers and perfluorinated organic compounds, could be detected in all species. By incorporating available published and unpublished data, we were able to produce time trends for pollutants and shell thickness over 4 decades.

  14. Feasibility of using fiber optics for monitoring ground water contaminants

    International Nuclear Information System (INIS)

    Hirschfeld, T.; Deaton, T.; Milanovich, F.; Klainer, S.M.

    1984-06-01

    The report contains the results of the initial feasibility study for a research program undertaken to develop the technology needed to use fiber optics for monitoring groundwater contaminants. The technology appears especially well suited to the requirements of detection monitoring where a few indicator parameters can be measured continuously by sensors placed down small-diameter monitoring wells. Data are generated at a remote, centrally located fluorimeter, connected to the sampling sites by inexpensive optical fibers. The analytical method is laser-induced fluorescence which gives the desired sensitivity. The optrode, a chemical system and/or a mechanical device at the distal end of a fiber optic, furnishes the needed specificity. Various fiber and optrode configurations have been evaluated and their applications to groundwater monitoring are discussed. Feasibility is shown for physical measurements such as temperature, pressure and pH. Chemical detection and quantification of the actinides, inorganic and organic chlorides, sulfates, alcohols, aldehydes, pesticides and tracer materials are presented. Finally, it is shown that the need for smaller diameter wells (as compared to conventional sampling methods), and the ability to make up to 50 unattended in situ measurements, using a reasonably priced centralized fluorometer system connected to the sampling sites by inexpensive optical fibers, results in acceptable economy

  15. Tritium contamination and monitoring at Frascati Neutron Generator

    Energy Technology Data Exchange (ETDEWEB)

    Lucci, F.; Sandri, S.; Ianni, A. [ENEA, Frascati (Italy). Dipartimento Ambiente; Vasselli, R. [ANPA, Roma (Italy); Pillon, M.; Bettinali, L. [ENEA, Frascati (Italy). Dipartimento Energia

    1994-11-01

    The Frascati Neutron Generator (FGN) is a specialised 300 keV, 3 mA direct electrostatic deuteron accelerator which produces about 5-10{sup 1}1 14 MeV neutrons per second by D-T reactions on a tritium-titanium fixed target. This paper concerns the tritium contamination control and monitoring aspects after some months of testing and a preliminary period of operation of the plant. The tritium monitoring system is composed of both on-line and off-line devices to control the tritium concentration in the atmosphere measured from different parts of the plant: vacuum exhaust clean up (VECU) system, stack, etc. The on-line devices are three flux monitors, that sample continuosly the air from up to eight different points in the plant. The passive sampling system is designed to select the chemical form of tritium and to collect respectively HTO and HT in two different cartridges filled with an appropriate drying material. The response of the on-line tritium monitor system are exposed and discussed: some measurements performed with atmosphere dehumidifying apparatus of this system are described and the relevant results are analysed.

  16. Tritium contamination and monitoring at Frascati Neutron Generator

    International Nuclear Information System (INIS)

    Lucci, F.; Sandri, S.; Ianni, A.; Pillon, M.; Bettinali, L.

    1994-11-01

    The Frascati Neutron Generator (FGN) is a specialised 300 keV, 3 mA direct electrostatic deuteron accelerator which produces about 5-10 1 1 14 MeV neutrons per second by D-T reactions on a tritium-titanium fixed target. This paper concerns the tritium contamination control and monitoring aspects after some months of testing and a preliminary period of operation of the plant. The tritium monitoring system is composed of both on-line and off-line devices to control the tritium concentration in the atmosphere measured from different parts of the plant: vacuum exhaust clean up (VECU) system, stack, etc. The on-line devices are three flux monitors, that sample continuosly the air from up to eight different points in the plant. The passive sampling system is designed to select the chemical form of tritium and to collect respectively HTO and HT in two different cartridges filled with an appropriate drying material. The response of the on-line tritium monitor system are exposed and discussed: some measurements performed with atmosphere dehumidifying apparatus of this system are described and the relevant results are analysed

  17. Nuclear plant's virtual simulation for on-line radioactive environment monitoring and dose assessment for personnel

    International Nuclear Information System (INIS)

    Mol, Antonio Carlos A.; Jorge, Carlos Alexandre F.; Lapa, Celso Marcelo F.

    2009-01-01

    This paper reports the use of nuclear plant's simulation for online dose rate monitoring and dose assessment for personnel, using virtual reality technology. The platform used for virtual simulation was adapted from a low cost game engine, taking advantage of all its image rendering capabilities, as well as the physics for movement and collision, and networking capabilities for multi-user interactive navigation. A real nuclear plant was virtually modeled and simulated, so that a number of users can navigate simultaneously in this virtual environment in first or third person view, each one receiving visual information about both the radiation dose rate in each actual position, and the radiation dose received. Currently, this research and development activity has been extended to consider also on-line measurements collected from radiation monitors installed in the real plant that feed the simulation platform with dose rate data, through a TCP/IP network. Results are shown and commented, and other improvements are discussed, as the execution of a more detailed dose rate mapping campaign.

  18. Environmental geophysics and geochemistry for contamination mapping and monitoring 1

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Tai Sup; Lee, Sang Kyu; Hong, Young Kook [Korea Inst. of Geology Mining and Materials, Taejon (Korea, Republic of); and others

    1995-12-01

    This study aims to provide the technologies which can be practically used for contamination mapping and monitoring. To accomplish this goal, the geophysical and geochemical expertise and techniques commonly used in the mineral resources exploration are employed. In the first year of the three-year-long project, the purpose of the study is to introduce the optimum methodologies among the geophysical and geochemical techniques to tackle the various cases of environmental contamination. To achieve the purpose, case studies of the developed countries were surveyed and analyzed through the various kinds of literatures. The followings are categorized to be solved by geophysical methods: 1) delineation of water system pollution by acid mine drainage and distributions of waste rocks in the closed mine area, 2) defining boundaries of subsurface contamination due to oil seepage, 3) zoning of sea water intrusion in the seashore or subsurface geology highly containing salt, 4) locating of buried metallic wastes such as pipes and drums which can cause the secondary pollution by corrosion, and 5) outlining of the subsurface area polluted by leachate from the landfill. To experiment the above items, various geophysical methods were applied to the corresponding test sites. From these experiments, the applicabilities of the respective geophysical method were analyzed, and the optimum methods were derived for the various pollution types. Furthermore, electric and electromagnetic surveys data processing software were developed to quantitatively interpret and highly resolve the geology. The environmental assignments which can be solved by geochemical methods include: 1) drainage pollution by coal mine effluents, 2)subsurface contamination of oil-spill, 3) sea water intrusion, 4) dispersion of toxic heavy metallic elements in the metal mines, and 5) radon environmental geochemistry. The appropriate test sites for applying the geochemical methods were selected. (Abstract Truncated)

  19. Development of custom LCD based portable survey/contamination monitors

    International Nuclear Information System (INIS)

    Reddy, J.D.

    2010-01-01

    Equipments for carrying out radiation survey measurements for alpha, beta and gamma radiations have evolved considerably with the advancements in Electronics overtime. There are 2 major classes of portable instruments available from most manufacturers - (a) Analog indicator type (b) Direct digital readout type. Analog meters give a direct quantifying feel to radiation levels though they are not rich features nor they have smartness like a digital meter. Digital versions have advantages of direct readout numerically and configurable as per users requirements. To achieve best features of both the techniques a dual indicator type LCD module comprising of Analog indicating LCD segments and digital readout indicating 7 segments has been developed. This LCD comprising of LCD glass and its display driver has been deployed across various types of survey meters and contamination monitors manufactured by Nucleonix. This display now facilitates direct readout of dose rate/count rate in various units simultaneously in both analog LCD scale and direct digital indication. (author)

  20. Experiences in monitoring airborne radioactive contamination in JAERI

    International Nuclear Information System (INIS)

    Ikezawa, Y.; Okamoto, T.; Yabe, A.

    1980-01-01

    The following results were obtained at the Japan Atomic Energy Research Institute (JAERI) from experience in air monitoring at the hot cells for handling highly radioactive materials, the glove box containing plutonium and the cell for producing 99 Mo. (1) The ratios of activities of airborne dust to those of whole dust were of the order of 10 -2 for the semi-volatile form of 125 Sb, and 10 -3 to 10 -4 for the particulate form of 137 Cs, 144 Ce and 144 Pr, when irradiated fuels were cut in the hot cells. (2) The activity median aerodynamic diameter (AMAD) of airborne particle size distributions varied from O.4 to 15 μm with changing geometric standard deviation (sigmasub(g)) 1.7 to 7, depending on types of metallurgical treatment of fuels and on kinds of work in the cells. (3) A resuspension factor (the ratio of the concentration of airborne contamination to the surface contamination) was found to be 4x10 -8 to approximately 2x10 -7 cm -1 for plutonium oxide deposited on the floor surface. (4) The collection efficiency of the charcoal-loaded filter paper for airborne radioiodine, consisting of 60% inorganic and 40% organic iodide, was over 95% under conditions of relative humidity 40 to approximately 80% and face velocity 50 cm/sec, during the production of 99 Mo. (H.K.)

  1. Modification of beta dose evaluation algorithm for better accuracy in personnel monitoring

    International Nuclear Information System (INIS)

    Rakesh, R.B.; Kumar, Munish; Sneha, C.; Ratna, P.; Datta, D.

    2016-01-01

    Dose due to beta radiations is the main contributor to the skin dose. Assessment of individual dose (whole body, skin, extremity) in India is based on CaSO 4 :Dy based Teflon embedded TLD badge used for personnel monitoring. The design of the dosemeter enables identification of radiation type which, in turn, allows use of radiation specific algorithm for dose evaluation. The difference of response of three discs of the TLD badge to beta radiation in beta/beta-gamma fields is due to the presence of different filters corresponding to the three discs. The response of disc under metal filter (D 1 ) to beta being negligible while that of open disc (D 3 ) is the maximum. The ratio of response of open disc to that under Perspex (D 3 /D 2 ) to beta is highly dependent on its energy and angle of incidence. Therefore estimation of dose due to beta is based on response of open disc corrected for the energy of beta using D 3 /D 2

  2. Cytogenetic monitoring of personnel occupationally exposed to microwave radiation of GEM radar

    International Nuclear Information System (INIS)

    Garaj-Vrhovac, Vera; Gajski, Goran; Brumen, Vlatka

    2008-01-01

    In the present study we analyzed and followed-up on the DNA damaging effects of microwave radiation of GEM radar equipment within microwave field of 10 μW/cm 2 to 10 mW/cm 2 in personnel occupationally exposed to frequency range of 1.5 GHz to 10.9 GHz. The single cell gel electrophoresis (SCGE)/comet assay as a tool for the bio monitoring of individuals accidentally, environmentally or occupationally exposed to physical or chemical agents was used to evaluate possible genotoxic effect on peripheral human blood lymphocytes. The comet assay is a method that allows efficient determination of single strand breaks (SSB) and double-strand breaks (DSB), as well as alkali-labile sites in the DNA of single cells. The comet assay was carried out under alkaline conditions. We measured the baseline comet assay effect in whole blood samples. Parameter of the comet assay was studied in workers occupationally exposed to microwave radiation of GEM radar and in corresponding unexposed control subjects. It was found that in the subjects who were occupationally exposed to microwave radiation, the levels of DNA damage increased compare to control group and showed interindividual variations. As a measure of DNA damage tail length was used, calculated from the centre of the head and presented in micrometers (μm). Mean value of exposed group was 13.54±1.44 as opposed to control mean value that was 13.15±1.39. Differences between mean tail lengths were statistically significant (P<0.05, ANOVA). The results of this study indicate that individuals occupationally exposed to microwave frequency of GEM radar equipment may experience an increased genotoxic risk, emphasizing the importance of individual bio monitoring, limiting exposure and radiation safety programs. (author)

  3. Comparative survey of site and personnel monitoring characteristics for operation of various types of diagnostic-X ray equipment

    International Nuclear Information System (INIS)

    Lyarskij, P.P.; Zol'nikova, N.I.

    1977-01-01

    Diagnostic X-ray machines in present use at medical facilities differ in design and operating parameters, this diversity producing, in turn, a variety of local radiological situations and levels of personnel exposure. Based on radiological safety characterization of working conditions, the authors present a breakdown of contemporary diagnostic X-ray equipment types, based on detailed examination of each group in terms of their associated site monitoring and dosimetry patterns. The paper reports data on personnel exposure levels not only as a function of equipment design and operating characteristics but also according to types of occupational activities for particular medical personnel groups (radiologists, surgeons, anesthesiologists, etc.). Included are health physics data for domestic and foreign X-ray equipment, levels of local and absorbed doses for radiologists, cardiovascular surgeons, neurosurgeons, urologists, traumatologists, anesthesiologists, etc. Measures are recommended for optimizing their activities from the standpoint of radiation safety. (author)

  4. Radiological Monitoring Equipment For Real-Time Quantification Of Area Contamination In Soils And Facility Decommissioning

    International Nuclear Information System (INIS)

    M. V. Carpenter; Jay A. Roach; John R Giles; Lyle G. Roybal

    2005-01-01

    The environmental restoration industry offers several systems that perform scan-type characterization of radiologically contaminated areas. The Idaho National Laboratory (INL) has developed and deployed a suite of field systems that rapidly scan, characterize, and analyze radiological contamination in surface soils. The base system consists of a detector, such as sodium iodide (NaI) spectrometers, a global positioning system (GPS), and an integrated user-friendly computer interface. This mobile concept was initially developed to provide precertification analyses of soils contaminated with uranium, thorium, and radium at the Fernald Closure Project, near Cincinnati, Ohio. INL has expanded the functionality of this basic system to create a suite of integrated field-deployable analytical systems. Using its engineering and radiation measurement expertise, aided by computer hardware and software support, INL has streamlined the data acquisition and analysis process to provide real-time information presented on wireless screens and in the form of coverage maps immediately available to field technicians. In addition, custom software offers a user-friendly interface with user-selectable alarm levels and automated data quality monitoring functions that validate the data. This system is deployed from various platforms, depending on the nature of the survey. The deployment platforms include a small all-terrain vehicle used to survey large, relatively flat areas, a hand-pushed unit for areas where maneuverability is important, an excavator-mounted system used to scan pits and trenches where personnel access is restricted, and backpack- mounted systems to survey rocky shoreline features and other physical settings that preclude vehicle-based deployment. Variants of the base system include sealed proportional counters for measuring actinides (i.e., plutonium-238 and americium-241) in building demolitions, soil areas, roadbeds, and process line routes at the Miamisburg Closure

  5. Nuclear electronic components of surface contamination monitor based on multi-electrode proportional counter

    International Nuclear Information System (INIS)

    Du Xiangyang; Zhang Yong; Han Shuping; Rao Xianming; Fang Jintu

    2001-01-01

    The nuclear electronic components applying in Portal Monitor and Hands and Feet Surface Contamination Monitor were based on modern integrated circuit are introduced. The detailed points in circuit design and manufacturing technique are analyzed

  6. Unregulated Contaminant Monitoring Rule 2 (UCMR 2), (2008-2010) Occurrence Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Unregulated Contaminant Monitoring Rule supporting the second cycle (UCMR 2) of monitoring, conducted under EPA oversight, was published in the Federal Register...

  7. Awareness of bispectral index monitoring system among the critical care nursing personnel in a tertiary care hospital of India

    Directory of Open Access Journals (Sweden)

    Shikha Thakur

    2011-01-01

    Full Text Available Background: Bispectral index monitoring system (BIS is one of the several systems used to measure the effects of anaesthetic and sedative drugs on the brain and to track changes in the patient′s level of sedation and hypnosis. BIS monitoring provides information clinically relevant to the adjustment of dosages of sedating medication. It can help the nursing personnel in preventing under- and over sedation among intensive care unit (ICU patients. Objective: The present study was conducted to assess the knowledge of nursing personnel working in the ICU regarding BIS. Methods: Fifty-four subjects participated in the study. A structured questionnaire was developed to assess the knowledge of the nursing personnel regarding BIS. Focus group discussions were held among the nursing personnel to know their views regarding BIS. Results: Mean age (years of the subjects was 30.7΁7.19 (21-47 years, with a female preponderance. Although the use of BIS in ICU is not common, majority (94.44% were aware of BIS and its purpose. 79.62% of the subjects knew about its implication in patient care. The mean knowledge score of the subjects was 11.87΁2.43 (maximum score being 15. Conclusion: There exists an awareness among the critical care nursing staff in our institution regarding BIS and its clinical implications. Its use in the critical care setting may benefit the patients in terms of providing optimal sedation.

  8. Program of individual monitoring of the internal contamination and their implementation in the Republic the Cuba

    International Nuclear Information System (INIS)

    Lopez Bejerano, Gladys M.; Capote Ferrera, Eduardo; Fernandez Gomez, Isis M.; Acosta Rodriguez, Nancy; Carrazana Gonzalez, Jorge A.; Cruz Suarez, Rodolfo

    2008-01-01

    Full text: In different Cuban institutions linked fundamentally to the medical practice of nuclear medicine and the investigations, it is worked with sources open of ionizing radiations, that which makes indispensable the existence of a system of radiological surveillance that includes the control radiological individual of the received doses as a result of the occupational, such exhibition that is guaranteed that the exhibition of the Hard-working Exposed Occupationally, stay inside the recommended limits, in the International Basic Norms of Protection against the Ionizing radiations and safe-deposit of the Sources of Radiation (NBIS) and in turn adopted in the Norma Cuban. From the year 1986 in the Center of Protection and Hygiene of the Radiations is carried out in way centralized this control; but with the inconvenience of not being able to carry out the same one to workers from the domestic interior when not being feasible the transfer of these toward its headquarters, reason why the doses were ignored received in an important number of these. In and of itself the Laboratory of Internal Contamination of this institution in these years has developed managed works to define firstly, for each institution, the program of monitoring of the internal contamination of its workers using for it the methodology recommended by the OIEA where the potential doses are evaluated that for incorporation these they receive and whose results suggested the introduction of a program of individual monitoring as behavior to continue in most of the institutions. In correspondence with it was designed and established a program that included the study of feasibility of the existent equipment in the institutions to carry out the monitoring of the internal contamination using technical of measuring in vivo and in vitro, as it corresponds, their calibration, the establishment of procedures that respond to the requirements of a System of Quality for the Norma ISO/IEC 17025 and

  9. Contamination Control and Monitoring of Tap Water as Fluid in Industrial Tap Water Hydraulic Systems

    DEFF Research Database (Denmark)

    Conrad, Finn; Adelstorp, Anders

    1998-01-01

    Presentation of results and methods addressed to contamination control and monitoring of tap water as fluid in tap water hydraulic systems.......Presentation of results and methods addressed to contamination control and monitoring of tap water as fluid in tap water hydraulic systems....

  10. Contamination monitoring of Na 131 I levels in therapy unit of Research Institute for Nuclear Medicine, Tehran University of Medical Sciences by indirect method (Wipe test)

    International Nuclear Information System (INIS)

    Beiki, D.; Shahhosseini, S.; Eftekhari, M.; Takavar, A.; Fard-Esfahani, A.

    2003-01-01

    Contamination with radiopharmaceuticals in nuclear medicine centres in addition to being a health concern requires time consuming decontamination efforts. According to Nuclear Regulatory Commission Contamination should be monitored in nuclear medicine centers where radiopharmaceuticals are prepared and administrated at the end of each working session; otherwise, contamination spread to other areas not only equipment but also personnel and other people will be expected. The wipe test for the presence of radioactivity is accomplished by wiping the surface over an area approximately 100 cm 2 with an absorbent paper, then counting it in an appropriate radiation detector. In this study, contamination monitoring of patient's rooms (4 rooms), entrance corridor, patient's corridor, waiting room, control room (nursing station), radiopharmaceutical storage room in therapy unit of Research Institute for Nuclear Medicine, Shariati hospital was performed by indirect method. Based on the results, some areas including storage room were contaminated. There was also a direct relationship between dose administrated and levels of contamination in patient's rooms. Regarding high uptake of iodine by thyroid gland and damaging effects of Na 131 I, weekly wipe tests are required to determine the level of contamination. Patient's rooms after discharging the patients and before re hospitalization specially should be checked. If these tests reveal contamination over standard levels, appropriate decontamination procedures should be carried out immediately

  11. Requirements for internal contamination monitoring units; Anforderungen an Inkorporationsmessstellen

    Energy Technology Data Exchange (ETDEWEB)

    Werner, E. [GSF, Inst. fuer Biophysikalische Strahlenforschung, Frankfurt am Main (Germany); Beyer, D. [Forschungszentrum Juelich, Abt. ASS (Germany); Doerfel, H. [Hauptabteilung Sicherheit, Kernforschungszentrum Karlsruhe (Germany); Erlenbach, H. [Zentralstelle fuer Sicherheitstechnik NRW, Duesseldorf (Germany); Fischbach, G. [Siemens Brennelementewerk, Hanau (Germany); Henrichs, K. [Siemens AG, Muenchen (Germany); Keller, K.D. [Radiologische Universitaetsklinik, Tuebingen (Germany); Koenig, K. [Bundesamt fuer Strahlenschutz, ISH, Neuherberg (Germany); Riedel, W. [Freie Univ. Berlin, Klinikum Steglitz (Germany); Scheler, R. [Bundesamt fuer Strahlenschutz, FB Strahlenschutz, Berlin (Germany); Schieferdecker, H. [Hauptabteilung Sicherheit, Kernforschungszentrum Karlsruhe (Germany)

    1994-12-31

    For the evaluation of internal contamination by officially authorized monitoring units according to section 63 (6) of the German radiation protection ordinance, a directive will be prepared in order to define uniform requirements for the laboratories in charge of incorporation monitoring by appointment of the relevant authorities. These requirements refer to equipment, to performance of measurements, to interpretation of measured values, to quality control as well as to documentation and to delivery of results. The duties of such laboratories comprise measurements of radioactivity, evaluation of intakes of radionuclides and of the resulting internal radiation dose, but also transmission of results to the employer, to the central dose registry, and under certain circumstances to the authorities. Among the requirements to be met by the laboratory for incorporation control are a sufficient measuring efficiency, the implementation of in-house checks, and the participation in intercomparison programs. For the accomplishment of such duties the laboratory needs appropriate apparatus, rooms, facilities, and staffing. (orig.) [Deutsch] Zur Ermittlung der Koerperdosen nach Paragraph 63 StrlSchV sind fuer die gemaess Abs. 6 von der zustaendigen Behoerde zu bestimmenden Messstellen in einer Richtlinie einheitliche Anforderungen festzulegen. Diese beziehen sich auf deren Ausstattung, die Durchfuehrung der Messungen, Auswertungen und Qualitaetskontrollen sowie die Aufzeichnung und Uebermittlung der Ergebnisse. Die Aufgaben der Messstellen umfassen die Messungen der Radioaktivitaet im Koerper bzw. in Koerperausscheidungen, die Ermittlung der Zufuhr an Radionukliden sowie der daraus resultierenden Koerperdosis und die Weiterleitung der Ergebnisse an den Auftraggeber, an das zentrale Dosisregister und in bestimmten Faellen an die Behoerde. Zu den von einer Messstelle zu erfuellenden Anforderungen gehoeren eine ausreichende Messeffektivitaet, die Durchfuehrung von Eigenkontrollen

  12. Surface Contamination Monitor and Survey Information Management System

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-02-01

    Shonka Research Associates, Inc.`s (SRA) Surface Contamination Monitor and Survey Information management System (SCM/SIMS) is designed to perform alpha and beta radiation surveys of floors and surfaces and document the measured data. The SRA-SCM/SIMS technology can be applied to routine operational surveys, characterization surveys, and free release and site closure surveys. Any large nuclear site can make use of this technology. This report describes a demonstration of the SRA-SCM/SIMS technology. This demonstration is part of the chicago Pile-5 (CP-5) Large-Scale Demonstration Project (LSDP) sponsored by the US Department of Energy (DOE), Office of Science and Technology (ST), Deactivation and Decommissioning Focus Area (DDFA). The objective of the LSDP is to select and demonstrate potentially beneficial technologies at the Argonne National Laboratory-East`s (ANL) CP-5 Research Reactor Facility. The purpose of the LSDP is to demonstrate that by using innovative and improved deactivation and decommissioning (D and D) technologies from various sources, significant benefits can be achieved when compared to baseline D and D technologies.

  13. Surface Contamination Monitor and Survey Information Management System

    International Nuclear Information System (INIS)

    1998-02-01

    Shonka Research Associates, Inc.'s (SRA) Surface Contamination Monitor and Survey Information management System (SCM/SIMS) is designed to perform alpha and beta radiation surveys of floors and surfaces and document the measured data. The SRA-SCM/SIMS technology can be applied to routine operational surveys, characterization surveys, and free release and site closure surveys. Any large nuclear site can make use of this technology. This report describes a demonstration of the SRA-SCM/SIMS technology. This demonstration is part of the chicago Pile-5 (CP-5) Large-Scale Demonstration Project (LSDP) sponsored by the US Department of Energy (DOE), Office of Science and Technology (ST), Deactivation and Decommissioning Focus Area (DDFA). The objective of the LSDP is to select and demonstrate potentially beneficial technologies at the Argonne National Laboratory-East's (ANL) CP-5 Research Reactor Facility. The purpose of the LSDP is to demonstrate that by using innovative and improved deactivation and decommissioning (D and D) technologies from various sources, significant benefits can be achieved when compared to baseline D and D technologies

  14. Study of monitoring protection of radionuclides contamination in organism by autoradiography

    International Nuclear Information System (INIS)

    Zhu Shoupeng; Kang Baoan; He Guangren

    1987-01-01

    In view of the exceptionally important role of the medical radiation protection in human health, the authors try to study on the monitoring of internal contamination of radionuclides in organism by different autoradiographic methods, such as: monitoring of the body retention of isolated or combined radionuclides by freezing microautoradiography; monitoring of blood, bone marrow and excreta radioactive samples by smear autoradiography; differentiation of two radionuclides contamination by double radionuclide autoradiography; especially, monitoring of low level of radionuclides contamination by fluorescence sensitization autoradiography. The sensitivity of autoradiographic formation was increased by the scintillator by 10 times

  15. Microbial Contamination on Used Surgical Masks among Hospital Personnel and Microbial Air Quality in their Working Wards: A Hospital in Bangkok

    Directory of Open Access Journals (Sweden)

    Pipat Luksamijarulkul

    2014-09-01

    Full Text Available Objective: To assess the relationship of bacterial and fungal contamination on used surgical masks worn by the hospital personnel and microbial air quality in their working wards. Methods: This is a cross-sectional study of 230 used surgical masks collected from 214 hospital personnel, and 215 indoor air samples collected from their working wards to culture for bacterial and fungal counts. This study was carried out at the hospital in Bangkok. Group or genus of isolated bacteria and fungi were preliminarily identified by Gram’s stain and lacto-phenol cotton blue. Data were analyzed using paired t-test and Pearson’s correlation coefficient at the significant level of p<0.050. Results: Means and standard deviation of bacterial and fungal contamination on inside area of the used masks were 47 ± 56 and 15 ± 9 cfu/ml/piece, and on outside area were 166 ± 199 and 34 ± 18 cfu/ml/piece, respectively, p<0.001. The bacterial and fungal contamination on used masks from hospital personnel working in the male and female medical wards and out-patient department, as well as the bacterial and fungal counts of the indoor air sample collected from the same area were relatively higher than the other wards. The predominant isolated bacteria and fungi contaminated on inside and outside areas of the used masks and air samples were similar (Staphylococcus spp. and Aspergillus spp.; respectively. For its relationship, results found that bacterial and fungal counts in air samples showed significantly positive correlation with the bacterial contamination load on outside area of the used masks, r=0.16, p=0.018 and r=0.21, p=0.003, respectively. Conclusion: High bacterial contamination on outside area of the used masks was demonstrated, and it showed a significant correlation with microbial air quality of working wards.

  16. Eco-monitoring of highly contaminated areas: historic heavy metal contamination in tree ring records

    Science.gov (United States)

    Baross, Norbert; Jordán, Győző; Albert, Julianna; Abdaal, Ahmed; Anton, Attila

    2014-05-01

    This study examines and compares tree rings of trees grown in a mining area highly contaminated with heavy metals. Tree rings offers an excellent opportunity for eco-monitoring polluted areas. Contamination dispersion from the source to the receptors can be studied in time and space. The sampled area is located in the eastern part of the Matra Mts. of the Inner-Carpathian calc-alkaline Volcanic Arc (Hungary) with abundant historical ore (Pb, Zn, Cu, etc.) mining in the area. Dense forests are composed of the most typical association of the Turkey oak (Quercus cerris). Scots pine (Pinus sylvestris), European black pine (Pinus nigra), oak (Quercus robur), beech (Fagus sylvatica), and hornbeam (Carpinus betulus) also occurs in the landscape. Sampled trees are located within a 1km radius of the abandoned historic ore mines. Sample sites were located above the old mines and waste rock heaps, under the waste rock heaps and on the floodplain of the Ilona Creek. The sampled trees were selected by the following criteria: the tree should be healthy, showing no signs of thunderbolt or diseases and having a minimum diameter of 50 cm. Samples were taken with a tree borer at the height of 150 cm. At the same time, soil samples were also taken near the trees in a 25 cm depth. Prior to laboratory analysis, the samples measured and air dried. Every fifth years tree ring was taken from the samples under microscope, working backwards from the most recent outer ring (2012, the year of the sampling). Samples were digested with a mixture of H2SO4 and H2O2m in Teflon vessels in a microwave unit. The samples were analyzed by ICP-OES instrument. The results were evaluated with statistical method. Results revealed a consistent picture showing distinct locations and years of the contamination history in the former mining area. Some elements are built into the trees more efficiently than other elements depending on mobility in the soil solution that is influenced by soil chemical properties

  17. Position-sensitive radiation monitoring (surface contamination monitor). Innovative technology summary report

    International Nuclear Information System (INIS)

    1999-06-01

    The Shonka Research Associates, Inc. Position-Sensitive Radiation Monitor both detects surface radiation and prepares electronic survey map/survey report of surveyed area automatically. The electronically recorded map can be downloaded to a personal computer for review and a map/report can be generated for inclusion in work packages. Switching from beta-gamma detection to alpha detection is relatively simple and entails moving a switch position to alpha and adjusting the voltage level to an alpha detection level. No field calibration is required when switching from beta-gamma to alpha detection. The system can be used for free-release surveys because it meets the federal detection level sensitivity limits requires for surface survey instrumentation. This technology is superior to traditionally-used floor contamination monitor (FCM) and hand-held survey instrumentation because it can precisely register locations of radioactivity and accurately correlate contamination levels to specific locations. Additionally, it can collect and store continuous radiological data in database format, which can be used to produce real-time imagery as well as automated graphics of survey data. Its flexible design can accommodate a variety of detectors. The cost of the innovative technology is 13% to 57% lower than traditional methods. This technology is suited for radiological surveys of flat surfaces at US Department of Energy (DOE) nuclear facility decontamination and decommissioning (D and D) sites or similar public or commercial sites

  18. Position-sensitive radiation monitoring (surface contamination monitor). Innovative technology summary report

    Energy Technology Data Exchange (ETDEWEB)

    1999-06-01

    The Shonka Research Associates, Inc. Position-Sensitive Radiation Monitor both detects surface radiation and prepares electronic survey map/survey report of surveyed area automatically. The electronically recorded map can be downloaded to a personal computer for review and a map/report can be generated for inclusion in work packages. Switching from beta-gamma detection to alpha detection is relatively simple and entails moving a switch position to alpha and adjusting the voltage level to an alpha detection level. No field calibration is required when switching from beta-gamma to alpha detection. The system can be used for free-release surveys because it meets the federal detection level sensitivity limits requires for surface survey instrumentation. This technology is superior to traditionally-used floor contamination monitor (FCM) and hand-held survey instrumentation because it can precisely register locations of radioactivity and accurately correlate contamination levels to specific locations. Additionally, it can collect and store continuous radiological data in database format, which can be used to produce real-time imagery as well as automated graphics of survey data. Its flexible design can accommodate a variety of detectors. The cost of the innovative technology is 13% to 57% lower than traditional methods. This technology is suited for radiological surveys of flat surfaces at US Department of Energy (DOE) nuclear facility decontamination and decommissioning (D and D) sites or similar public or commercial sites.

  19. The Advanced Monitoring Systems Initiative--Performance Monitoring for DOE Environmental Remediation and Contaminant Containment

    Science.gov (United States)

    Haas, W. J.; Venedam, R. J.; Lohrstorfer, C. F.; Weeks, S. J.

    2005-05-01

    The Advanced Monitoring System Initiative (AMSI) is a new approach to accelerate the development and application of advanced sensors and monitoring systems in support of Department of Energy needs in monitoring the performance of environmental remediation and contaminant containment activities. The Nevada Site Office of the National Nuclear Security Administration (NNSA) and Bechtel Nevada manage AMSI, with funding provided by the DOE Office of Environmental Management (DOE EM). AMSI has easy access to unique facilities and capabilities available at the Nevada Test Site (NTS), including the Hazardous Materials (HazMat) Spill Center, a one-of-a-kind facility built and permitted for releases of hazardous materials for training purposes, field-test detection, plume dispersion experimentation, and equipment and materials testing under controlled conditions. AMSI also has easy access to the facilities and considerable capabilities of the DOE and NNSA National Laboratories, the Special Technologies Laboratory, Remote Sensing Laboratory, Desert Research Institute, and Nevada Universities. AMSI provides rapid prototyping, systems integration, and field-testing, including assistance during initial site deployment. The emphasis is on application. Important features of the AMSI approach are: (1) customer investment, involvement and commitment to use - including definition of needs, desired mode of operation, and performance requirements; and (2) employment of a complete systems engineering approach, which allows the developer to focus maximum attention on the essential new sensing element or elements while AMSI assumes principal responsibility for infrastructure support elements such as power, packaging, and general data acquisition, control, communication, visualization and analysis software for support of decisions. This presentation describes: (1) the needs for sensors and performance monitoring for environmental systems as seen by the DOE Long Term Stewardship Science and

  20. Dosimetric system for measurement of radioactive contaminations

    International Nuclear Information System (INIS)

    Litynski, Z.; Pienkos, J.P.; Witkowski, J.; Zadrozny, S.

    1985-01-01

    A dosimetric system for personnel dosimetry and monitoring measuring a contamination without time delay and dead time is described. The system ensures many-point measurement and minimalization of background radiation influence. 1 fig. (A.S.)

  1. A quality control program for the thermoluminescence dosimeter (TLD) in personnel radiation monitoring

    International Nuclear Information System (INIS)

    Seo, Kyung Won; Kim, Jang Lyul; Lee, Sang Yoon; Lee, Hyung Sub

    1994-01-01

    High quality radiation dosimetry is essential for workers who rely upon personal dosemeters to record the amount of radiation to which they are exposed. The ministry of science and technology (MOST) issued a ministerial ordinance (No 199-15) about the technical criteria on personnel dosimeter processors on 1992. The purpose of this quality control program is to prescribe the procedures approved by the management of KAERI for implementing a quality badge service by means of TLD for personnel working in an area where they may be exposed to ionization radiation. (Author) 10 refs

  2. Post monitoring of a cyclodextrin remeditated chlorinated solvent contaminated aquifer

    Science.gov (United States)

    Blanford, W. J.

    2006-12-01

    Hydroxypropyl-â-cyclodextrin (HPâCD) has been tested successfully in the laboratory and in the field for enhanced flushing of low-polarity contaminants from aquifers. The cyclodextrin molecule forms a toroidal structure, which has a hydrophobic cavity. Within this cavity, organic compounds of appropriate shape and size can form inclusion complexes, which is the basis for the use of cyclodextrin in groundwater remediation. The hydrophilic exterior of the molecule makes cyclodextrin highly water-soluble. The solubility of cyclodextrins can be further enhanced by adding functional groups, such as hydroxypropyl groups, to the cyclodextrin core. The aqueous solubility of HPâCD exceeds 950 g/L. These high solubilities are advantageous for field applications because they permit relatively high concentrations of the flushing agent. In order for cyclodextrin to become a feasible remediative alternative, it must be demonstrate a short term resistance to biodegradation during field application, but ultimately biodegrade so as not to pose a long term presence in the aquifer. The potential for degradation of cyclodextrin as well as changes in the chlorinated solvents and groundwater geochemistry were examined during the post monitoring of a field demonstration in a shallow aquifer at Little Creek Naval Amphibious Base in Virginia. It was found that a portion of the cyclodextrin remaining in the aquifer after the cessation of field activities biodegraded during the 425 days of post monitoring. This degradation also led to the degradation of the chlorinated solvents trichloroethylene and 1,1-trichloroethane through both biological and chemical processes. The aquifer remained anaerobic with average dissolved oxygen levels below 0.5 mg/L. Dissolved nitrate and sulfate concentrations within the cyclodextrin plume decreased due their being used as terminal electron acceptors during the degradation of the cyclodextrin. The concentrations of total iron at the field site showed no

  3. Monitoring Potential Transport of Radioactive Contaminants in Shallow Ephemeral Channels: FY2015 and FY2016

    Energy Technology Data Exchange (ETDEWEB)

    Mizell, Steve A [Desert Research Inst. (DRI), Las Vegas, NV (United States); Miller, Julianne J [Desert Research Inst. (DRI), Las Vegas, NV (United States); McCurdy, Greg [Desert Research Inst. (DRI), Las Vegas, NV (United States); Campbell, Scott A [Desert Research Inst. (DRI), Las Vegas, NV (United States)

    2017-10-01

    The Desert Research Institute (DRI) is conducting a field assessment of the potential for contaminated soil to be transported from the Smoky Contamination Area (CA) as a result of storm runoff. This activity supports Nevada Nuclear Security Administration (NNSA) efforts to complete regulatory closure of the Soils Corrective Action Unit (CAU) contamination areas. The work is intended to confirm the likely mechanism of transport and determine the meteorological conditions that might cause movement of contaminated soils, as well as determine the particle size fraction that is most closely associated with transported radionuclide-contaminated soils. These data will facilitate the appropriate closure design and post-closure monitoring program.

  4. Monitoring Potential Transport of Radioactive Contaminants in Shallow Ephemeral Channels: FY2013 and FY2014 (revised)

    Energy Technology Data Exchange (ETDEWEB)

    Mizell, Steve A. [Desert Research Inst. (DRI), Las Vegas, NV (United States); Miller, Julianne J. [Desert Research Inst. (DRI), Las Vegas, NV (United States); McCurdy, Greg D. [Desert Research Inst. (DRI), Reno, NV (United States); Campbell, Scott A. [Desert Research Inst. (DRI), Las Vegas, NV (United States)

    2017-06-01

    The Desert Research Institute (DRI) is conducting a field assessment of the potential for contaminated soil to be transported from the Smoky Contamination Area (CA) as a result of storm runoff, which supports National Nuclear Security Administration (NNSA) efforts to complete regulatory closure of the Soils Corrective Action Unit (CAU) contamination areas. The work is intended to confirm the likely mechanism of transport and determine the meteorological conditions that might cause movement of contaminated soils, as well as determine the particle size fraction that is most closely associated with transported radionuclide-contaminated soils. These data will facilitate the appropriate closure design and post-closure monitoring program.

  5. Calibration of personnel monitors by exposure to gamma radiation with energies up to 9 MeV

    International Nuclear Information System (INIS)

    Leao, J.L.B.; Cunha, P.G. da; Diz, R.; Oberhofer, M.

    Occupational exposure with photons of high energy (higher than those from 60 Co) might occur from nuclear reactors and accelerators. Radiation monitors for absorbed dose determination, however, often do not have a wall thickness sufficient to establish electronical equilibrium in that energy range. Using calibration factors determined for lower energies (calibration factors for 60 Co radiation) might cause a significant underestimation of the soft tissue absorbed dose. The calibration factor of the personnel monitors of the Eberline Instrument Co.based on TL dosimeters of LiF is reported. This monitor was calibrated with 9 MeV photons produced by thermal neutrons capture in a Nitarget, at an absorbed dose rate of 125 rads/h at the C.E.N. in France. The results are compared with the corresponding calibration factors for different energies up to 60 Co radiation determined in the IRD (Instituto de Radioprotecao e Dosimetria Rio de Janeiro). (Author) [pt

  6. Neutron personnel dosimetry

    International Nuclear Information System (INIS)

    Griffith, R.V.

    1981-01-01

    The current state-of-the-art in neutron personnel dosimetry is reviewed. Topics covered include dosimetry needs and alternatives, current dosimetry approaches, personnel monitoring devices, calibration strategies, and future developments

  7. Development of personnel radiation monitoring program for occupationally exposed workers in Malawian Hospitals : A case study of Kamuzu Central, Bwaila and Mtengo Wa Nthenga Hospitals

    International Nuclear Information System (INIS)

    Chinangwa, Getrude

    2016-07-01

    Malawi became an IAEA member state in 2006 and developed the Atomic Energy Act and Regulations in 2011 and 2012 respectively. However, regulatory authority and personnel monitoring services have not yet been established. As such, hospitals operating radiological services in Malawi do not have personnel monitoring programme. This study aimed at developing the personnel radiation monitoring program for three hospitals in Malawi namely; Kamuzu Central Hospital, Bwaila Hospital, and Mtengo wa Nthenga Hospital. A radiation protection questionnaire was administered to the X-ray Departments involved in the study to investigate radiation protection practices in the hospitals. Dose rate measurements in the facilities were taken using survey meters and doses to individuals were recorded using personal dosimeters. The results showed that the hospitals lack radiation protection program which covers the critical issues of quality assurance and control as well as the personnel dose monitoring. Average ambient dose rate values were 0.39 μSv/hr for Mtengo wa Nthenga Hospital, 5.03 μSv/hr for Bwaila Hospital and 4μSv/hr for Kamuzu Central Hospital. Average monthly dose for workers was 0.247 mSv. The study recommends the establishment of a regulatory authority, consistent dose assessment, quality control tests and structural shielding assessment in these and probably all the diagnostic facilities in Malawi. The personnel monitoring programme developed from this study is intended to guide diagnostic facilities and personnel monitoring service providers in Malawi in tracking and reporting exposure record for their occupationally exposed workers. (au)

  8. Trace Contaminant Monitor for Air in Spacecraft, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — A need exists for analyzers that can measure trace contaminants in air on board spacecraft. Toxic gas buildup can endanger the crew particularly during long...

  9. Contamination monitoring in radiation protection activities in Myanmar

    Energy Technology Data Exchange (ETDEWEB)

    Thin, K T; Htoon, S [Yangon Univ. (Myanmar). Dept. of Physics

    1997-06-01

    The radioactive contamination in rainwater, seawater, air, milk powder and other eatables were measured with low level counter assembly. The measured activities are found to be very low and well within the maximum permissible level. (author)

  10. Monitoring of Water and Contaminant Migration at the Groundwater-Surface Water Interface

    Science.gov (United States)

    2008-08-01

    seepage is occurring in a freshwater lake environment and to map the lateral extent of any subsurface contamination at the groundwater –surface water ...and Contaminant Migration at the Groundwater -Surface Water Interface August 2008 Report Documentation Page Form ApprovedOMB No. 0704-0188 Public...4. TITLE AND SUBTITLE Monitoring of Water and Contaminant Migration at the Groundwater -Surface Water Interface 5a. CONTRACT NUMBER 5b. GRANT NUMBER

  11. Development and Application of Devices for Remote Monitoring of Gamma-Ray Contamination at RECOM Ltd

    International Nuclear Information System (INIS)

    Ivanov, O.P.; Stepanov, V.E.; Chesnokov, A.V.; Sudarkin, A.N.; Urutskoev, L.I.

    1999-01-01

    Devices for remote monitoring of gamma-ray contamination develop at RECOM Ltd. are described and typical examples of their application are show. The following devices are discussed: spectrum-sensitive collimated devices for mapping of radioactivity on contaminated surfaces- scanning collimated Gamma Locator, device for field Cs-137 contamination mapping-CORAD; devices for gamma-ray imaging computer-controlled High-Energy Radiation Visualizer (HERV) and Coded Mask Imager

  12. Unregulated Contaminant Monitoring Rule 3 (UCMR 3), (2013-2015) Occurrence Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — The third Unregulated Contaminant Monitoring Rule (UCMR 3), conducted under EPA oversight, was published in the Federal Register on May 2, 2012. UCMR 3 requires...

  13. Remediating and Monitoring White Phosphorus Contamination at Eagle River Flats (Operable Unit C), Fort Richardson, Alaska

    National Research Council Canada - National Science Library

    Walsh, M. E; Racine, C. H; Collins, C. M; Walsh, M. R; Bailey, R. N

    2001-01-01

    .... Army Engineer District, Alaska, and U.S. Army Alaska, Public Works, describing the results of research, monitoring, and remediation efforts addressing the white phosphorus contamination in Eagle River Flats, an 865-ha estuarine salt marsh...

  14. Certified reference materials for organic contaminants for use in monitoring of the aquatic environment

    NARCIS (Netherlands)

    Boer, de J.; McGovern, E.

    2001-01-01

    Over the last three decades organic contaminants have been of increasing importance in environmental monitoring. Dioxins, furans, polychlorinated biphenyls and organochlorine pesticides have determined the environmental research agenda. This has led to an increasing demand for certified reference

  15. Microbial Contamination on Used Surgical Masks among Hospital Personnel and Microbial Air Quality in their Working Wards: A Hospital in Bangkok.

    Science.gov (United States)

    Luksamijarulkul, Pipat; Aiempradit, Natkitta; Vatanasomboon, Pisit

    2014-09-01

    To assess the relationship of bacterial and fungal contamination on used surgical masks worn by the hospital personnel and microbial air quality in their working wards. This is a cross-sectional study of 230 used surgical masks collected from 214 hospital personnel, and 215 indoor air samples collected from their working wards to culture for bacterial and fungal counts. This study was carried out at the hospital in Bangkok. Group or genus of isolated bacteria and fungi were preliminarily identified by Gram's stain and lacto-phenol cotton blue. Data were analyzed using paired t-test and Pearson's correlation coefficient at the significant level of pcontamination on inside area of the used masks were 47 ± 56 and 15 ± 9 cfu/ml/piece, and on outside area were 166 ± 199 and 34 ± 18 cfu/ml/piece, respectively, pcontamination on used masks from hospital personnel working in the male and female medical wards and out-patient department, as well as the bacterial and fungal counts of the indoor air sample collected from the same area were relatively higher than the other wards. The predominant isolated bacteria and fungi contaminated on inside and outside areas of the used masks and air samples were similar (Staphylococcus spp. and Aspergillus spp.; respectively). For its relationship, results found that bacterial and fungal counts in air samples showed significantly positive correlation with the bacterial contamination load on outside area of the used masks, r=0.16, p=0.018 and r=0.21, p=0.003, respectively. High bacterial contamination on outside area of the used masks was demonstrated, and it showed a significant correlation with microbial air quality of working wards.

  16. History, contamination and monitoring of water bodies at the P/A Mayak

    International Nuclear Information System (INIS)

    Drozhko, E.G.; Sharalapov, V.I.; Posokhov, A.K.; Kuzina, N.V.; Postovalova, G.A.

    1993-01-01

    The facts concerning the history and contamination data of surface water at Mayak Production Association are given in the article. Data about the monitoring of contaminated water are presented. The monitoring program solved three main problems: assessment of the water quality of basins, examination of water quality in accordance with actual specifications, and reception of new data about the migration of the most important radionuclides

  17. Theoretical considerations on design and analysis of monitoring systems for Pu-contaminated solid wastes

    International Nuclear Information System (INIS)

    Notea, A.

    1979-01-01

    Monitoring systems for plutonium contaminated wastes refers to both managerial regulations and instrumental hardware. Its design is inseparable from the design of the production line in the fuel handling facility, and depends on the general wastes management program. Characteristic functions of the monitors are discussed and the necessity of reference monitors is stressed. The reference monitor enables the formation of a quality scale. Guidelines for future R and D efforts are suggested

  18. Use of biological activities to monitor the removal of fuel contaminants - perspective for monitoring hydrocarbon contamination: A review

    CSIR Research Space (South Africa)

    Maila, MP

    2005-01-01

    Full Text Available Soil biological activities are vital for the restoration of soil contaminated with hydrocarbons. Their role includes the biotransformation of petroleum compounds into harmless compounds. In this paper, the use of biological activities as potential...

  19. Monitoring and radiation dose estimation for internal contamination of occupational workers

    Energy Technology Data Exchange (ETDEWEB)

    Kol, R; Laichter, Y [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev

    1996-12-01

    The assessment of interval radiation doses due to intake of radionuclides differs totally from external dosimetry. External dosimetry is relatively straight forward: Workers are equipped with appropriate dosimeters that give the dose upon direct reading. Internal dosimetry is actually an assessment of the dose based on results of personnel and environmental monitoring (authors).

  20. Screening and monitoring of main diseases a modern strategy of health maintenance in personnel of radiation dangerous plants

    International Nuclear Information System (INIS)

    Takhauov, R. M.; Karpov, A. B.; Kubat, I. I.; Maslyuk, A. I.; Semenova, Y. V.; Freidin, M. B.; Trivozhenko, A. B.; Litvinenko, T. M.

    2004-01-01

    Population health is greatly determined by social factors, mode of life, ecological situation, amount and quality of medical assistance. The analysis of reasons of health troubles increase in population should be done taking into account the above aspects. Main consideration should be given to the development of measures aimed at the highest possible decrease of technogenic and anthropogenic factors influence on a human. Thereupon a complex programme of main diseases screening and monitoring in the personnel of the Siberian Group of Chemical enterprises (SGCE) to be the biggest one among Russian atomic plants has been developed. The purpose of the present paper is to determine main diseases at the earliest stage, the decrease of death rate, as well as the complex estimation of technogenic factor influence on the personnel of radiation dangerous plants nand their offsprings. In this case a long-term effect of low doses seems to be the main risk factor. Taking into account the structure of death rate causes of the population of industrialized countries as well as the spectrum of stochastic effects of ionizing radiation, the screening of cardiac ischemia and arterial hypertension, localization of cancer and congenital malformations have been chosen as the program priorities. Algorithm of instrumental laboratory screening of a particular disease includes modern diagnostic tests. Groups ar risk are formed taking into account a complex of exogenous and endogenous risk factors (age, chronic diseases, bad habits, length of service at a radiation dangerous plant, dose loads, hereditary factors) and on the basis of the screening examination results. The information obtained is entered in the list of database of the Regional Medico dosimetric Register of the SGCE personnel and Seversk residents followed by analysis and monitoring of groups ar risk. (Author) 4 refs

  1. Use of an albedo neutron personnel dosimeter for X- and γ-ray monitoring

    International Nuclear Information System (INIS)

    Gorbics, S.G.; Nash, A.E.; Johnson, T.L.

    1981-01-01

    With a judicious choice of cadmium filter size and thickness, it is possible to use the information from the 7 LiF detectors used in an albedo neutron personnel dosimeter to determine an individual's X-and γ-ray exposure, thus eliminating the need for a separate dosimeter for this purpose. A filter area of 400 mm 2 and a thickness of 0.51 mm is shown to be optimum for a simple, plastic, dosimeter design using detectors held in dental-film size cards. (author)

  2. Monitoring Potential Transport of Radioactive Contaminants in Shallow Ephemeral Channels

    International Nuclear Information System (INIS)

    Miller Julianne J.; Mizell Steve A.; Nikolich George; Campbell Scott A.

    2012-01-01

    The U.S. Department of Energy (DOE) National Nuclear Security Administration (NNSA), Nevada Site Office (NSO), Environmental Restoration Soils Activity has authorized the Desert Research Institute (DRI) to conduct field assessments of potential sediment transport of contaminated soil from Corrective Action Unit (CAU) 550, Area 8 Smoky Contamination Area (CA), during precipitation runoff events. CAU 550 includes Corrective Action Sites (CASs) 08-23-03, 08-23-04, 08-23-06, and 08-23-07; these CASs are associated with tests designated Ceres, Smoky, Oberon, and Titania, respectively.

  3. Optimization of monitoring sewage with radionuclide contaminants. Optimizatsiya kontroya stochnykh vod, zagryaznennykh radionuklidami

    Energy Technology Data Exchange (ETDEWEB)

    Egorov, V N [Vsesoyuznyj Nauchno-Issledovatel' skij Inst. Neorganicheskikh Materialov, Moscow (Russian Federation)

    1991-03-01

    Recommendations on optimization of monitoring contaminated sewage aimed at enviromental protection agxinst radioactive contamination at minimum cost are presented. The way of selecting water sampling technique depends on water composition stability and flow rate. Depending on the type of radionuclide distribution in the sewage one can estimate minimum frequency of sampling or number of samples sufficient for assuring reliability of the conclusion on the excess or non-excess of permissible radioactive contamination levels, as well as analysis assigned accuracy. By irregular contaminated sewage-discharge and possibility of short-term releases of different form and duration, sampling should be accomplished through automatic devices of continuons or periodic operation.

  4. Understanding Fluid and Contaminant Movement in the Unsaturated Zone Using the INEEL Vadose Zone Monitoring System

    International Nuclear Information System (INIS)

    Hubbell, J. M.; Mattson, E. D.; Sisson, J. B.; Magnuson, S. O.

    2002-01-01

    DOE has hundreds of contaminated facilities and waste sites requiring cleanup and/or long-term monitoring. These contaminated sites reside in unsaturated soils (i.e. the vadose zone) above the water table. Some of these sites will require active remediation activities or removal while other sites will be placed under institutional controls. In either case, evaluating the effectiveness of the remediation strategy or institutional controls will require monitoring. Classical monitoring strategies implemented at RCRA/CERCLA sites require ground water sampling for 30 years following closure. The overall effectiveness of ground water sampling is diminished due to the fact that by the time you detect chemical transport from a waste site, a major contamination plume likely exists in the vadose zone and the aquifer. This paper suggests a more effective monitoring strategy through monitoring near the contaminant sites within the vadose zone. Vadose zone monitoring allows for quicker detection of potential contaminant transport. The INEEL Vadose Zone Monitoring System (VZMS) is becoming an accepted, cost effective monitoring technology for assessing contaminant transport at DOE facilities. This paper describes the technologies employed in the VZMS and describes how it was used at several DOE facilities. The INEEL VZMS has provided the information in developing and validating both conceptual and risk assessment models of contaminant transport at the Idaho National Engineering and Environmental Laboratory (INEEL), Oak Ridge National Laboratory (ORNL), Savannah River Site (SRS) and the Hanford site. These DOE sites exhibit a broad range of meteorologic, hydrologic and geologic conditions representative of various common geologic environments. The VZMS is comprised of advanced tensiometers, water content sensors, temperature sensors and soil and gas samplers. These instruments are placed at multiple depths in boreholes and allows for the detection of water movement in the

  5. The Development of a Sub-Surface Monitoring System for Organic Contamination in Soils and Groundwater

    Directory of Open Access Journals (Sweden)

    Sharon L. Huntley

    2002-01-01

    Full Text Available A major problem when dealing with environmental contamination is the early detection and subsequent surveillance of the contamination. This paper describes the potential of sub-surface sensor technology for the early detection of organic contaminants in contaminated soils, sediments, and landfill sites. Rugged, low-power hydrocarbon sensors have been developed, along with a data-logging system, for the early detection of phase hydrocarbons in soil. Through laboratory-based evaluation, the ability of this system to monitor organic contamination in water-based systems is being evaluated. When used in conjunction with specific immunoassays, this can provide a sensitive and low-cost solution for long-term monitoring and analysis, applicable to a wide range of field applications.

  6. Long-range alpha detection applied to soil contamination and waste monitoring

    International Nuclear Information System (INIS)

    MacArthur, D.W.; Allander, K.S.; Bounds, J.A.; Close, D.A.; McAtee, J.L.

    1992-01-01

    Alpha contamination monitoring has been traditionally limited by the short range of alpha particles in air and through detector windows. The long-range alpha detector (LRAD) described in this paper circumvents that limitation by detecting alpha-produced ions, rather than alpha particles directly. Since the LRAD is sensitive to all ions, it can monitor all contamination present on a large surface at one time. Because air is the ''detector gas,'' the LRAD can detect contamination on any surface to which air can penetrate. We present data showing the sensitivity of LRAD detectors, as well as documenting their ability to detect alpha sources in previously unmonitorable locations, and verifying the ion lifetime. Specific designs and results for soil contamination and waste monitors are also included

  7. Evaluation of indigenously developed plastic scintillator sheet detector for surface radioactive contamination monitoring application

    International Nuclear Information System (INIS)

    Sahani, R.M.; Chaudhary, H.S.; Mahala, V.K.; Senwar, K.R.; Meena, J.P.

    2018-01-01

    Radioactive contamination may be caused by release of radioactivity in the environment due to accident at nuclear plant/reactor or spillage of loose radioactive materials in a laboratory. The protection of workers from potentially hazardous radiations emitted by the contaminants is a matter of prime concern. The detection of such radiations requires a monitoring system capable of measuring the level of radioactivity at the contaminated site. Plastic scintillators are widely used for large area radiation monitoring due to the ease of preparation in different shape and sizes. These detectors are sensitive to beta and gamma radiation therefore can be used for monitoring of beta and gamma contamination. In this paper, performance results of indigenously developed plastic scintillator sheet of area 800 cm 2 are reported

  8. An overview of existing raptor contaminant monitoring activities in Europe

    NARCIS (Netherlands)

    Gomez-Ramirez, P.; Shore, R.F.; Brink, van den N.W.; Hattum, van B.; Bustnes, J.O.; Duke, G.; Fritsch, C.; Garcia-Fernandez, A.J.; Helander, B.O.; Jaspers, V.; Krone, O.; Martinez-Lopez, E.; Mateo, R.; Movalli, P.; Sonne, C.

    2014-01-01

    Biomonitoring using raptors as sentinels can provide early warning of the potential impacts of contaminants on humans and the environment and also a means of tracking the success of associated mitigation measures. Examples include detection of heavy metal-induced immune system impairment,

  9. ICPP digital wide area portal monitor

    International Nuclear Information System (INIS)

    Nichols, C.E.

    1978-01-01

    A portal montior is described which is used to check personnel for contamination. The monitor is extremely sensitive. In addition to personnel contamination control, it serves as an extremely effective SNM detector capable of detecting U-235 in half the quantities specified in Federal Standards

  10. A new risk and stochastic analysis of monitoring and remediation in subsurface contamination

    Science.gov (United States)

    Papapetridis, K.; Paleologos, E.

    2012-04-01

    Sanitary landfills constitute the most widely used management approach for the disposal of solid wastes because of their simplicity and cost effectiveness. However, historical records indicate that landfills exhibit a high failure rate of groundwater contamination. Successful detection of aquifer contamination via monitoring wells is a complicated problem with many factors, such as the heterogeneity of the geologic environment, the dispersion of contamination into the geologic medium, the quantity and nature of the contaminants, the number and location of the monitoring wells, and the frequency of sampling, all contributing to the uncertainty of early detection. Detection of contaminants, of course, is of value if remedial actions follow as soon as possible, so that the volume of contaminated groundwater to be treated is minimized. Practically, there is always a time lag between contaminant detection and remedial action response. Administrative decisions and arrangements with local contractors initiate remedial procedures introduces a time lag between detection and remediation time. During this time lag a plume continues to move into an aquifer contaminating larger groundwater volumes. In the present study these issues are addressed by investigating the case of instantaneous leakage from a landfill facility into a heterogeneous aquifer. The stochastic Monte Carlo framework was used to address, in two dimensions, the problem of evaluating the effectiveness of contaminant detection in heterogeneous aquifers by linear networks of monitoring wells. Numerical experiments based on the random-walk tracking-particle method were conducted to determine the detection probabilities and to calculate contaminated areas at different time steps. Several cases were studied assuming different levels of geologic heterogeneity, contamination dispersion, detectable contamination limits and monitoring wells' sampling frequencies. A new perspective is introduced for the correction of

  11. Monitoring of plutonium contaminated solid waste streams. Chapter IV: Passive neutron assay

    International Nuclear Information System (INIS)

    Birkhoff, G.; Bondar, L.

    1978-01-01

    The fundamentals of the passive neutron technique for the non destructive assay of plutonium bearing materials are summarized. A reference monitor for the passive neutron assay of Pu contaminated solids is described in terms of instrumental design principles and performances. The theoretical model of this reference monitor with pertinent nuclear data and functions for the interpretation of experimental data is given

  12. Experience of MAPS in monitoring of personnel movement with on-line database management system

    International Nuclear Information System (INIS)

    Rajendran, T.S.; Anand, S.D.

    1992-01-01

    As a part of physical protection system, access control system has been installed in Madras Atomic Power Station(MAPS) to monitor and regulate the movement of persons within MAPS. The present system in its original form was meant only for security monitoring. A PC based database management system was added to this to computerize the availability of work force for actual work. (author). 2 annexures

  13. Present status of contamination monitoring at the Dalat Nuclear Research Institute (DNRI)

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Hoang Van [Dalat Nuclear Research Inst. (Viet Nam)

    1997-06-01

    The Dalat nuclear research reactor was renovated and upgraded from the previous TRIGA reactor. In Vietnam, it is a unique nuclear device having suitable neutron flux for the radioisotope production and neutron activation analysis. Soon after the reactor reached its initial criticality in November 1983, a programme has been formed to develop the application of nuclear techniques in various fields. In addition, the use of radioisotopes for diagnostic, therapeutic and other research purposes has been in progress. In order to support these activities, the radiation protection, especially the radiation contamination monitoring has been properly paid attention to. In DNRI, the Radiation Protection Department is responsible for controlling and supervising radiation and working safety for all activities. In this paper, the following items are described on radiation contamination monitoring: controlled area, surface contamination monitoring, and airborne concentration monitoring. (G.K.)

  14. Development of plastic scintillator based food radioactivity contamination monitoring system

    International Nuclear Information System (INIS)

    Parihar, A.; Sahani, R.M.; Mahala, V.K.; Vaijapurkar, S.G.

    2016-01-01

    Radioactivity is naturally present in soil, water and food stuffs. Food can be contaminated after discharge of radioactivity into the environment from industries that concentrate natural radionuclide and from civil or military nuclear operations. The contamination can be in three ways; by direct deposition, through the food chain and induced radioactivity due to exposure of high neutron flux. The health effects on human depend on the type of radionuclide and the length of time people are exposed to it. The studies of fission product behaviour in the food chain have revealed radionuclide Strontium-90, Caesium 137 and Iodine-131 are of major concern. Plastic scintillator is already developed indigenously at Defence Laboratory, Jodhpur. Efforts has been made to develop a portable field instrument using plastic scintillator for assessment of beta ( 90 Sr) and gamma ( 137 Cs and 131 I) radioactivity in food

  15. Long-range alpha detector for contamination monitoring

    International Nuclear Information System (INIS)

    MacArthur, D.W.; Allander, K.S.; McAtee, J.L.

    1991-01-01

    Historically, alpha detectors have been limited by the very short range of alpha particles in air and by relatively poor sensitivity, even if the particles are intercepted. Of necessity, these detectors are operated in a vacuum or in close proximity to the source if reasonable efficiency is desired. In our new long-range alpha detector (LRAD), alpha particles interact with the ambient air, producing ionization in the air at the rate of about 30,000 ion pairs per MeV of alpha energy. These charges can be transported over significant distances (several meters) in a moving current of air generated by a small fan. An ion chamber located in front of the fan measures the current carried by the moving ions. The LRAD-based monitor is more sensitive and more thorough than conventional monitors. We present current LRAD sensitivity limits and results, practical monitor designs, and proposed uses for LRAD monitors. 4 refs., 6 figs

  16. High-Performance Contaminant Monitor for Spacecraft, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The Vision for Space Exploration demands increasing reliance on real-time trace gas monitors onboard spacecraft. Present grab samples and badges will be inadequate...

  17. Bulk monitoring of soil for low level transuranic contamination

    International Nuclear Information System (INIS)

    Mandler, J.W.; Randolph, P.D.

    1976-01-01

    A system using γ-ray analysis was developed to survey the soil surrounding retrieval barrels for liquid radioactive waste containing 239 Pu and 241 Am. The performance of scintillation detectors of various sizes for monitoring soil samples was evaluated

  18. An assessment of two decades of contaminant monitoring in the Nation’s Coastal Zone.

    OpenAIRE

    Kimbrough, K. L.; Lauenstein, G. G.; Christensen, J. D.; Apeti, D. A.

    2008-01-01

    Executive Summary: Information found in this report covers the years 1986 through 2005. Mussel Watch began monitoring a suite of trace metals and organic contaminants such as DDT, PCBs and PAHs. Through time additional chemicals were added, and today approximately 140 analytes are monitored. The Mussel Watch Program is the longest running estuarine and coastal pollutant monitoring effort conducted in the United States that is national in scope each year. Hundreds of scientific journal art...

  19. Application of the personnel photographic monitoring method to determine equivalent radiation dose beyond proton accelerator shielding

    International Nuclear Information System (INIS)

    Gel'fand, E.K.; Komochkov, M.M.; Man'ko, B.V.; Salatskaya, M.I.; Sychev, B.S.

    1980-01-01

    Calculations of regularities to form radiation dose beyond proton accelerator shielding are carried out. Numerical data on photographic monitoring dosemeter in radiation fields investigated are obtained. It was shown how to determine the total equivalent dose of radiation fields beyond proton accelerator shielding by means of the photographic monitoring method by introduction into the procedure of considering nuclear emulsions of division of particle tracks into the black and grey ones. A comparison of experimental and calculational data has shown the applicability of the used calculation method for modelling dose radiation characteristics beyond proton accelerator shielding [ru

  20. Luminescence monitoring of oil or tar contamination for industrial hygiene

    International Nuclear Information System (INIS)

    Gammage, R.B.; Vo-Dinh, T.

    1980-01-01

    Synfuel plants produce potentially carcinogenic oils and tars. Exposure of workers to these tars and oils is difficult to avoid completely and occurs via direct contact with dirty surfaces or condensation of escaped fumes onto or within the body. Surface skin, measurements are made directly with a near-ultraviolet luminoscope employing a fiber optics lightguide and a stethoscopic cap pressed against the skin. This instrument is especially suitable for measuring ng to μg/cm 2 amounts of residual contamination remaining on the surface of the skin after washing. To minimize the potential for carcinogenicity, the excitating ultraviolet light intensity is only 1/100th that of sunlight. (orig.)

  1. Effective energies and exposure determinations of two different energy X-ray beams incident on a personnel monitor

    International Nuclear Information System (INIS)

    Okuno, E.; Cruz, M.T. da

    1984-01-01

    The effective energy of one X or gamma ray beam can be determined by means of two thermoluminescent (TL) dosemeters mounted between suitable filters. However, it has been observed that personnel monitors exposed to two different energy ionizing radiations provide different effective energies depeding on the type of TL phosphor used. This fact could be a powerful tool for identifying exposures to radiation with quite different effective energies which are very common in practice. Two types of TL dosemeters were used : pellets of cold pressed natural fluoride and NaCl developed in our own laboratory, and LiF, TLD-100 from Harshaw Chemical Co.. Experimental results obtained with these combined dosemeters after irradiation with different sets of exposures and energy values of ionizing radiations are also presented. (Author) [pt

  2. 40 CFR 141.40 - Monitoring requirements for unregulated contaminants.

    Science.gov (United States)

    2010-07-01

    ... reporting level b 5—Sampling location c 6—Period during which monitoring to be completed Acetanilide... μg/L EPTDS 1/1/2008-12/31/2010 Acetanilide Pesticide Parent Compounds Acetochlor 34256-82-1 EPA 525.2... preserve each sample separately. Samples collected for the analysis of Acetanilide “parent” pesticides and...

  3. Subsurface Contaminant Focus Area: Monitored Natural Attenuation (MNA)--Programmatic, Technical, and Regulatory Issues

    Energy Technology Data Exchange (ETDEWEB)

    Krupka, Kenneth M.; Martin, Wayne J.

    2001-07-23

    Natural attenuation processes are commonly used for remediation of contaminated sites. A variety of natural processes occur without human intervention at all sites to varying rates and degrees of effectiveness to attenuate (decrease) the mass, toxicity, mobility, volume, or concentration of organic and inorganic contaminants in soil, groundwater, and surface water systems. The objective of this review is to identify potential technical investments to be incorporated in the Subsurface Contaminant Focus Area Strategic Plan for monitored natural attenuation. When implemented, the technical investments will help evaluate and implement monitored natural attenuation as a remediation option at DOE sites. The outcome of this review is a set of conclusions and general recommendations regarding research needs, programmatic guidance, and stakeholder issues pertaining to monitored natural attenuation for the DOE complex.

  4. The Opera Instrument: An Advanced Curation Development for Mars Sample Return Organic Contamination Monitoring

    Science.gov (United States)

    Fries, M. D.; Fries, W. D.; McCubbin, F. M.; Zeigler, R. A.

    2018-01-01

    Mars Sample Return (MSR) requires strict organic contamination control (CC) and contamination knowledge (CK) as outlined by the Mars 2020 Organic Contamination Panel (OCP). This includes a need to monitor surficial organic contamination to a ng/sq. cm sensitivity level. Archiving and maintaining this degree of surface cleanliness may be difficult but has been achieved. MSR's CK effort will be very important because all returned samples will be studied thoroughly and in minute detail. Consequently, accurate CK must be collected and characterized to best interpret scientific results from the returned samples. The CK data are not only required to make accurate measurements and interpretations for carbon-depleted martian samples, but also to strengthen the validity of science investigations performed on the samples. The Opera instrument prototype is intended to fulfill a CC/CK role in the assembly, cleaning, and overall contamination history of hardware used in the MSR effort, from initial hardware assembly through post-flight sample curation. Opera is intended to monitor particulate and organic contamination using quartz crystal microbalances (QCMs), in a self-contained portable package that is cleanroom-compliant. The Opera prototype is in initial development capable of approximately 100 ng/sq. cm organic contamination sensitivity, with additional development planned to achieve 1 ng/sq. cm. The Opera prototype was funded by the 2017 NASA Johnson Space Center Innovation Charge Account (ICA), which provides funding for small, short-term projects.

  5. Hand Monitor for Simultaneous Measurements of Alpha and Beta Contamination

    International Nuclear Information System (INIS)

    Andersson, I.Oe.; Braun, J.; Soederlund, B.

    1960-11-01

    An instrument is described which measures α and β contamination of the hands simultaneously. This has been achieved by using as detectors 8 flow counters paired in 4 units of two chambers, one unit for each side of the hand. The inner chamber of every unit (adjacent to the hands) delivers α-pulses, the outer chambers deliver β-pulses. When two finger contacts are pushed the detectors are closing around the hands and the measurement is started. Audible and visual warnings operate when the MPL is exceeded. Similar warnings ope.rate if hands are removed before the end of the counting period. The activity levels are logarithmically indicated on four pointer instruments, which are automatically zeroed when the next measurement is started. The instrument is now commercially available

  6. Hand Monitor for Simultaneous Measurements of Alpha and Beta Contamination

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, I Oe; Braun, J; Soederlund, B

    1960-11-15

    An instrument is described which measures {alpha} and {beta} contamination of the hands simultaneously. This has been achieved by using as detectors 8 flow counters paired in 4 units of two chambers, one unit for each side of the hand. The inner chamber of every unit (adjacent to the hands) delivers {alpha}-pulses, the outer chambers deliver {beta}-pulses. When two finger contacts are pushed the detectors are closing around the hands and the measurement is started. Audible and visual warnings operate when the MPL is exceeded. Similar warnings ope.rate if hands are removed before the end of the counting period. The activity levels are logarithmically indicated on four pointer instruments, which are automatically zeroed when the next measurement is started. The instrument is now commercially available.

  7. Design and development of food radioactivity contamination monitoring system

    International Nuclear Information System (INIS)

    Narayan, Pradeep; Vaijapurkar, S.G.; Bohra, Dinesh

    2014-01-01

    Radioactivity has been part and parcel of living being since the existence of the earth. It is available everywhere in our environment and being responsible for evolution of life on earth at some extent. However, the radioactivity in excess of the natural radioactive can have harmful effects on living being. The radiation exposure can be of external or internal origin or of both. The main route of internal radiation exposure is through the contaminated food chains. The concentration of natural radioactivity in food varies in range of 40-600 Bq/kg. 40 K being the single major radionuclide of food with typical radioactivity; 50 Bq/kg in milk, 420 Bq/kg in milk powder, 165 Bq/kg in potatoes, and 125 Bq/kg in beef is also the main contributor of natural radiation doses to human being. Measurement of radioactivity in food items and drinks is thus very important in controlling the internal exposure to human being especially in case of nuclear disaster. Though, the methods and techniques for food radioactivity measurement already existing, the need of portable instrument is warranted to measure the radioactivity in food items in raw form. Measurement of radioactivity may help in quick and mass screening of food items in case of nuclear emergencies. Any enhanced level of radioactivity in food items especially in case of nuclear emergency need to be evaluated for controlling its spread and restriction of consumption by the public. This way, it may help in managing internal radioactivity contamination to human being

  8. Image Analysis in the Field of Oil Contamination Monitoring

    OpenAIRE

    Ceco, Ema

    2011-01-01

    Monitoring wear particles in lubricating oils allows specialists to evaluate thehealth and functionality of a mechanical system. The main analysis techniquesavailable today are manual particle analysis and automatic optical analysis. Man-ual particle analysis is effective and reliable since the analyst continuously seeswhat is being counted . The drawback is that the technique is quite time demand-ing and dependent of the skills of the analyst. Automatic optical particle countingconstitutes o...

  9. Environmental monitoring of Columbia River sediments: Grain-size distribution and contaminant association

    Energy Technology Data Exchange (ETDEWEB)

    Blanton, M.L.; Gardiner, W.W.; Dirkes, R.L.

    1995-04-01

    Based on the results of this study and literature review, the following conclusions can be made: Sediment grain size and TOC (total organic carbon) influence contaminant fate and transport (in general, sediments with higher TOC content and finer grain-size distribution can have higher contaminant burdens than sediments from a given river section that have less TOC and greater amounts of coarse-grained sediments). Physiochemical sediment characteristics are highly variable among monitoring sites along the Columbia River. Sediment grain characterization and TOC analysis should be included in interpretations of sediment-monitoring data.

  10. Environmental monitoring of Columbia River sediments: Grain-size distribution and contaminant association

    International Nuclear Information System (INIS)

    Blanton, M.L.; Gardiner, W.W.; Dirkes, R.L.

    1995-04-01

    Based on the results of this study and literature review, the following conclusions can be made: Sediment grain size and TOC (total organic carbon) influence contaminant fate and transport (in general, sediments with higher TOC content and finer grain-size distribution can have higher contaminant burdens than sediments from a given river section that have less TOC and greater amounts of coarse-grained sediments). Physiochemical sediment characteristics are highly variable among monitoring sites along the Columbia River. Sediment grain characterization and TOC analysis should be included in interpretations of sediment-monitoring data

  11. Second IRMF comparison of surface contamination monitor calibrations 2001-2002

    CERN Document Server

    Scott, C J

    2002-01-01

    The Ionising Radiations Metrology Forum (IRMF) organised a second comparison of surface contamination monitor calibrations in which twenty establishments in the UK participated. The exercise involved the circulation of three surface contamination monitors for calibration using large area reference sources available in the participants' laboratories. The instruments used were a Mini Instruments EP15, a Berthold LB122 and an Electra ratemeter with DP6AD probe. The instrument responses were calculated by the individual participants and submitted to the for analysis along with details of the reference sources used. Details of the estimated uncertainties were also reported. The results are compared and demonstrate generally satisfactory agreement between the participating establishments.

  12. Proposed training program for construction personnel involved in remedial action work at sites contaminated by naturally occurring radionuclides

    International Nuclear Information System (INIS)

    Berven, B.A.; Goldsmith, W.A.; Haywood, F.F.; Schiager, K.J.

    1979-01-01

    Many sites used during the early days of the US atomic energy program are contaminated with radionuclides of the primordial decay chains (uranium, thorium, and actinium series). This contamination consists of residues resulting from refining and processing uranium and thorium. Preparation of these sites for release to unrestricted private use will involve the assistance of construction workers, many of whom have limited knowledge of the hazards associated with radioactive materials. Therefore, there is a need to educate these workers in the fundamentals of radioactive material handling to minimize exposures and possible spread of contamination. This training should disseminate relevant information at an appropriate educational level and should instill a cautious, common-sense attitude toward the handling of radioactive materials. The training should emphasize basic information concerning environmental radiation within a context of relative risk. A multi-media format, including colorful visual aids, demonstration, and discussion, should be used to maximize motivation and retention. A detailed, proposed training program design is presented

  13. Effect of the temperature and relative humidity in dosemeters used for personnel monitoring

    International Nuclear Information System (INIS)

    Antonio Filho, J.

    1982-12-01

    The systematics of the combined effect of temperature and humidity on photographic dosimeters of the type Agfa-Gevaert, Kodak type II, III and the thermoluminescent dosimeters LiF:Mg,Ti (TLD-100, Harshaw), D-CaSO 4 :Dy-0,4 (Teledyne), e CaSO 4 :Dy+NaCl (IPEN), used in personal monitoring in Brazil was investigated, in the temperature range of 20 0 C to 50 0 C and relative humidity of 65% to 95%, in order to determine the best manner of utilization of these detectors in Brazilian climatic conditions. The dosimeters were studied in different forms of packing-sheet such as aluminezed paper and polyethylene. For the determination of the systematics, the dosimeters were irradiated in three conditions: before, during and after of storage in climatic chambers to a maximum period of 60 days. It was found that the dosimetric filmes and thermoluminescent dosimeter CaSO 4 :Dy+NaCl without protection, presented a high dependence to temperature and humidity, and when protected presented good results. Therefore, the best manner of utilization of these monitors in environments with relative humidity and temperature greater them 75% and 30 0 C respectively, is achieved with the protection of aluminized paper. The LiF:Mg,Ti and D+CaSO 4 :Dy-0,4 dosimeters can be utilized in their original form because they presented low dependence with humidity and temperature in the range studied. (Author) [pt

  14. Tritium contaminated surface monitoring with a solid - state device

    International Nuclear Information System (INIS)

    Culcer, Mihai; Iliescu, Mariana; Curuia, Marian; Enache, Adrian; Stefanescu, Ioan; Ducu, Catalin; Malinovschi, Viorel

    2004-01-01

    The low energy of betas makes tritium difficult to detect. However, there are several methods used in tritium detection, such as liquid scintillation and ionization chambers. Tritium on or near a surface can be also detected using proportional counters and, recently, solid state devices. The paper presents our results in the design and achievement of a surface tritium monitor using a PIN photodiode as a solid state charged particle detector to count betas emitted from the surface. That method allows continuous, real-time and non-destructively measuring of tritium. (authors)

  15. Mobile means for the monitoring of atmospheric contamination in a reactor building

    International Nuclear Information System (INIS)

    Marques, S.; Lestang, M.

    2009-01-01

    After having evoked the context and challenges of contamination monitoring when exploiting nuclear reactors, the authors discuss the representativeness of the atmospheric contamination measurement as it depends on the different physicochemical forms of radionuclides present in the circuits. They indicate the different gaseous or aerosol radioactive elements which are monitored within EDF installations. They discuss the incorporation of monitoring means at the installation design level, briefly present the use of beacons inside and outside the reactor building. They describe how monitoring is organized on the basis of alert threshold adjustments: an investigation threshold and an evacuation threshold. They discuss the beacon (or sensor) selection and indicate recommendations for their implementation for optimization purposes. They indicate where these beacons are installed and evoke the experimentation of networked mobile beacons with data remote transmission

  16. Monitoring of contamination of atmospheric environment by radiation

    International Nuclear Information System (INIS)

    Ise, Hiroaki

    1995-01-01

    Atmospheric pollution has become a worldwide problem regardless of developed industrial nations and developing countries. In particular, the pollution due to automobile exhaust gas, the carcinogenic particles in diesel exhaust and their relation to various respiratory diseases are the problems. Nitrogen oxides and sulfur oxides in exhaust gas become the cause of acid rain. Radiation began to be utilized for the measurement of the concentration of floating particles and the amount of fallout dust, the forecast of the generation and diffusion of pollutants, the elucidation of the contribution of generation sources in wide areas and so on. In this report, the circumstances that radiation became to be utilized for monitoring atmospheric environment and the present status and the perspective of the radiation utilization in the field of the preservation of atmospheric environment are described. The progress of the method of measuring floating particles in Japan is explained. The automatic measurement of floating particles by β-ray absorption method and the application of β-ray absorption method to the measurement of the amount of fallout dust, generation source particles and the exposure to floating particles of individuals for health control are described. The utilization of radiation for real time monitoring, the investigation of the generation of blown-up dust, atmospheric diffusion experiment and the elucidation of the contribution of generation sources by PIXE radioactivation analysis are reported. (K.I.)

  17. Osprey: worldwide sentinel species for assessing and monitoring environmental contamination in rivers, lakes, reservoirs, and estuaries.

    Science.gov (United States)

    Grove, Robert A; Henny, Charles J; Kaiser, James L

    2009-01-01

    In the United States, many fish and wildlife species have been used nationwide to monitor environmental contaminant exposure and effects, including carcasses of the bald eagle (Haliaeetus leucocephalus), the only top avian predator regularly used in the past. Unfortunately, bald eagles are sensitive to investigator intrusion at the nest. Thus, the osprey (Pandion haliaetus) is evaluated as a potential sentinel species for aquatic ecosystems. Several characteristics support the choice of the osprey as a sentinel species, including: (1) fish-eating diet atop the aquatic food web, (2) long-lived with strong nest fidelity, (3) adapts to human landscapes (potentially the most contaminated), (4) tolerates short-term nest disturbance, (5) nests spatially distributed at regular intervals, (6) highly visible nests easily located for study, (7) ability to accumulate most, if not all, lipophilic contaminants, (8) known sensitivity to many contaminants, and (9) nearly a worldwide distribution. These osprey traits have been instrumental in successfully using the species to understand population distribution, abundance, and changes over time; the effects of various contaminants on reproductive success; how contaminants in prey (fish on biomass basis) contribute to egg concentrations (i.e., biomagnification factors); and spatial residue patterns. Data summarized include nesting population surveys, detailed nesting studies, and chemical analyses of osprey egg, organ, blood, and feather samples for contaminants that bioaccumulate and/or biomagnify in aquatic food webs; and biochemical evaluations of blood and various organs. Studies in the United States, Canada, Mexico, Europe, and elsewhere have shown the osprey to be a useful sentinel species for monitoring selected environmental contaminants, including some emerging contaminants in lakes, reservoirs, rivers, and estuaries.

  18. Cold Vacuum Drying facility personnel monitoring system design description (SYS 12); FINAL

    International Nuclear Information System (INIS)

    PITKOFF, C.C.

    1999-01-01

    This document describes the Cold Vacuum Drying Facility (CVDF) instrument air (IA) system that provides instrument quality air to the CVDF. The IA system provides the instrument quality air used in the process, HVAC, and HVAC instruments. The IA system provides the process skids with air to aid in the purging of the annulus of the transport cask. The IA system provides air for the solenoid-operated valves and damper position controls for isolation, volume, and backdraft in the HVAC system. The IA system provides air for monitoring and control of the HVAC system, process instruments, gas-operated valves, and solenoid-operated instruments. The IA system also delivers air for operating hand tools in each of the process bays

  19. HFS-II hands and feet contamination monitor for α, β

    International Nuclear Information System (INIS)

    Du Xiangyang; Han Shuping; Wang Xiaodong; Fan Liya; Zhang Yong; Rao Xianming; Fang Jintu

    1999-11-01

    HFS-II Hands and Feet Contamination Monitor for α, β is a necessary device which monitors the entrance of controlling area of nuclear power plant and nuclear facility, and it consists of nuclear detector, nuclear electronic circuit, computer data processing and controlling divisions, input/output controlling etc. Physical indicators conform to the requirements of relative national standard GB8703-87 and department standard EJ/T586

  20. Integrating Modeling and Monitoring to Provide Long-Term Control of Contaminants

    International Nuclear Information System (INIS)

    Fogwell, Th.

    2009-01-01

    An introduction is presented of the types of problems that exist for long-term control of radionuclides at DOE sites. A breakdown of the distributions at specific sites is given, together with the associated difficulties. A paradigm for remediation showing the integration of monitoring with modeling is presented. It is based on a feedback system that allows for the monitoring to act as principal sensors in a control system. Currently the establishment of a very prescriptive monitoring program fails to have a mechanism for improving models and improving control of the contaminants. The resulting system can be optimized to improve performance. Optimizing monitoring automatically entails linking the monitoring with modeling. If monitoring designs were required to be more efficient, thus requiring optimization, then the monitoring automatically becomes linked to modeling. Records of decision could be written to accommodate revisions in monitoring as better modeling evolves. The technical pieces of the required paradigm are already available; they just need to be implemented and applied to solve the long-term control of the contaminants. An integration of the various parts of the system is presented. Each part is described, and examples are given. References are given to other projects which bring together similar elements in systems for the control of contaminants. Trends are given for the development of the technical features of a robust system. Examples of monitoring methods for specific sites are given. The examples are used to illustrate how such a system would work. Examples of technology needs are presented. Finally, other examples of integrated modeling-monitoring approaches are presented. (authors)

  1. Bringing together raptor collections in Europe for contaminant research and monitoring in relation to chemicals regulations.

    Science.gov (United States)

    Movalli, Paola; Dekker, René; Koschorreck, Jan; Treu, Gabriele

    2017-11-01

    Raptors are good sentinels of environmental contamination and there is good capability for raptor biomonitoring in Europe. Raptor biomonitoring can benefit from natural history museums (NHMs), environmental specimen banks (ESBs) and other collections (e.g. specialist raptor specimen collections). Europe's NHMs, ESBs and other collections hold large numbers of raptor specimens and samples, covering long periods of time. These collections are potentially a valuable resource for contaminant studies over time and space. There are strong needs to monitor contaminants in the environment to support EU and national chemical management. However, data on raptor specimens in NHMs, ESBs and other collections are dispersed, few are digitised, and they are thus not easy to access. Specimen coverage is patchy in terms of species, space and time. Contaminant research with raptors would be facilitated by creating a framework to link relevant collections, digitising all collections, developing a searchable meta-database covering all existing collections, making them more visible and accessible for contaminant research. This would also help identify gaps in coverage and stimulate specimen collection to fill gaps in support of prioritised contaminant monitoring. Collections can further support raptor biomonitoring by making samples available for analysis on request.

  2. Using tree swallows to monitor impacts of aquatic contamination in Great Lakes areas of concern

    International Nuclear Information System (INIS)

    Patnode, K.A.; Bodenstein, B.; Hetzel, R.; Pearson, S.

    1995-01-01

    Tree swallows were used to evaluate movement and potential impacts of contaminants from sediments in Newton Creek (diesel range organics: DROs) and Sheboygan River (PCBs), tributaries to Lake Superior and Lake Michigan, respectively. Contaminated sites occurred along the course of each river, while reference sites were located upstream or on a nearby river. Productivity was monitored and eggs, day 1 nestlings, and day 12 nestlings were collected from each nest. Whole body or egg homogenates were analyzed for PCBs or DROs. EROD activity in livers from day 12 nestlings is being determined for both PCB and DRO exposures. In the Newton Creek study, hatching success was similar for DRO and reference sites. DROs were detected in gastrointestinal tracts of 1 nestling from the reference and 1 from the contaminated site. DROs were not detected in any egg samples. In the Sheboygan River study, hatching success rates differed between 1 reference and 1 contaminated river segment. PCB daily accumulation rates from day 1 to day 12 nestlings were computed for Sheboygan River. All nestlings at reference nests had negative rates due to growth dilution effects. Preliminary analyses indicate the average rate for nestlings from contaminated segments of the river was 220.3 ng/g/day. These 1995 findings will be combined with 1996 data to evaluate the effectiveness of tree swallows for monitoring ecosystem impacts of aquatic contaminants in Wisconsin

  3. Implementation and Impact of an Automated Group Monitoring and Feedback System to Promote Hand Hygiene Among Health Care Personnel

    Science.gov (United States)

    Conway, Laurie J.; Riley, Linda; Saiman, Lisa; Cohen, Bevin; Alper, Paul; Larson, Elaine L.

    2015-01-01

    Article-at-a-Glance Background Despite substantial evidence to support the effectiveness of hand hygiene for preventing health care–associated infections, hand hygiene practice is often inadequate. Hand hygiene product dispensers that can electronically capture hand hygiene events have the potential to improve hand hygiene performance. A study on an automated group monitoring and feedback system was implemented from January 2012 through March 2013 at a 140-bed community hospital. Methods An electronic system that monitors the use of sanitizer and soap but does not identify individual health care personnel was used to calculate hand hygiene events per patient-hour for each of eight inpatient units and hand hygiene events per patient-visit for the six outpatient units. Hand hygiene was monitored but feedback was not provided during a six-month baseline period and three-month rollout period. During the rollout, focus groups were conducted to determine preferences for feedback frequency and format. During the six-month intervention period, graphical reports were e-mailed monthly to all managers and administrators, and focus groups were repeated. Results After the feedback began, hand hygiene increased on average by 0.17 events/patient-hour in inpatient units (interquartile range = 0.14, p = .008). In outpatient units, hand hygiene performance did not change significantly. A variety of challenges were encountered, including obtaining accurate census and staffing data, engendering confidence in the system, disseminating information in the reports, and using the data to drive improvement. Conclusions Feedback via an automated system was associated with improved hand hygiene performance in the short term. PMID:25252389

  4. Implementation and impact of an automated group monitoring and feedback system to promote hand hygiene among health care personnel.

    Science.gov (United States)

    Conway, Laurie J; Riley, Linda; Saiman, Lisa; Cohen, Bevin; Alper, Paul; Larson, Elaine L

    2014-09-01

    Despite substantial evidence to support the effectiveness of hand hygiene for preventing health care-associated infections, hand hygiene practice is often inadequate. Hand hygiene product dispensers that can electronically capture hand hygiene events have the potential to improve hand hygiene performance. A study on an automated group monitoring and feedback system was implemented from January 2012 through March 2013 at a 140-bed community hospital. An electronic system that monitors the use of sanitizer and soap but does not identify individual health care personnel was used to calculate hand hygiene events per patient-hour for each of eight inpatient units and hand hygiene events per patient-visit for the six outpatient units. Hand hygiene was monitored but feedback was not provided during a six-month baseline period and three-month rollout period. During the rollout, focus groups were conducted to determine preferences for feedback frequency and format. During the six-month intervention period, graphical reports were e-mailed monthly to all managers and administrators, and focus groups were repeated. After the feedback began, hand hygiene increased on average by 0.17 events/patient-hour in inpatient units (interquartile range = 0.14, p = .008). In outpatient units, hand hygiene performance did not change significantly. A variety of challenges were encountered, including obtaining accurate census and staffing data, engendering confidence in the system, disseminating information in the reports, and using the data to drive improvement. Feedback via an automated system was associated with improved hand hygiene performance in the short-term.

  5. Personnel dose equivalent monitoring at SLAC using lithium-fluoride TLD's [thermoluminescent dosimeters

    International Nuclear Information System (INIS)

    Jenkins, T.M.; Busick, D.D.

    1987-03-01

    TLD's replaced film badges in the early 1970's for all dose equivalent monitoring, both neutron and photon, and for all locations at SLAC. The photon TLD's, composed of Li-7 loaded teflon discs, are calibrated using conventional gamma-ray sources; i.e., Co-60, Cs-137, etc. For these TLD's a nominal value of 1 nC/mrem is used, and is independent of source energy for 100 keV to 3 MeV. Since measured dose equivalents at SLAC are only a small fraction of the allowable levels, it was not deemed necessary to develop neutron dosimeters which would measure dose equivalent accurately for all possible neutron spectra. Today, wallet TLD's, composed of pairs of Li-7 and Li-6 discs, are used, with the Li-6 measuring only thermal neutrons; i.e., they aren't moderated in any way to make them sensitive to neutrons with energies greater than thermal. The assumption is made that there is a correlation between thermal neutron fluences and fast neutron fluences around the research area where almost all neutron doses (exclusive of sealed sources) are received. The calibration factor for these Li-6 TLD's is 1 nC/mrem of fast neutrons. The method of determining the validity of this calibration is the subject of this note. 4 refs., 9 figs., 1 tab

  6. Detection of microbial contaminations in drinking water using ATP measurements – evaluating potential for online monitoring

    DEFF Research Database (Denmark)

    Vang, Óluva Karin; Corfitzen, Charlotte B.; Albrechtsen, Hans-Jørgen

    2011-01-01

    There is an increasing call for fast and reliable methods for continuous monitoring of microbial drinking water quality in order to protect public health. The potential for Adenosine triphosphate (ATP) measurements as a real-time analysis for continuous monitoring of microbial drinking water...... quality was investigated through simulation of two contamination scenarios, i.e. drinking water contaminated with waste water and surface water at various concentrations. With ATP measurements it was possible to detect waste water diluted 1000-10,000 times in drinking water depending on sensitivity...... of reagent kit. Surface water diluted 100-1000 times was detected in drinking water with ATP measurements. ATP has the potential as an early warning tool, especially in the period when the contamination concentration is high. 2011 © American Water Works Association AWWA WQTC Conference Proceedings All Rights...

  7. SoilCAM: soil contamination: advanced integrated characterisation and time-lapse monitoring

    NARCIS (Netherlands)

    French, H.K.; Zee, van der S.E.A.T.M.; Meju, M.

    2009-01-01

    The SoilCAM project is aimed at improving current methods for monitoring contaminant distribution and biodegradation in the subsurface. Currently proven methods, based on invasive sampling of soil, soil water and gaseous phase, are unable to provide sufficiently accurate data with high enough

  8. The last generation of contamination and exposure rate meters and monitors designed in Boris Kidric Institute

    International Nuclear Information System (INIS)

    Koturovic, A.M.; Sobajic, M.V.; Smelcerovic, M.A.; Damljanovic, D.D.; Drndarevic, V.R.

    1989-01-01

    The last generation of contamination and exposure rate meters and monitors designed and produced in Boris Kidric Institute, presented in this paper, are digital survey instruments. The common principle of these instruments is the 'simple precision' concept, i.e. predetermined time pulse counting. This principle is discussed and basic structure of these instruments is shown with their possibilities and features (author)

  9. Mussels and sediment as monitoring tools for contaminants: which to use when?

    Science.gov (United States)

    For decades, sediments and mussels have been used to assess the ecological and human health risks associated with concentrations of bioavailable organic and metal contaminants in a variety of coastal-wide and localized monitoring programs. Mussels (Mytilus edulis) bioaccumulate o...

  10. Monitoring exposure of personnel to volatile nitrosamines in the laboratory environment

    Energy Technology Data Exchange (ETDEWEB)

    Issenberg, P; Swanson, S E

    1980-01-01

    A convenient sampling method was developed for collection of volatile nitrosamines from large-volume air samples. Stainless steel tubes containing 0.3 g Tenax GC were employed to collect nitrosamines from 5-30 1 air samples. Nitrosamines were eluted from the sample tubes with diethylether to minimize formation of artifacts which were observed when thermal desorption was employed. Eluates were analysed directly by GC-TEA and nitrosamine identities were confirmed using high-resolution GC-MS with selected ion-monitoring. The detection limit was approximately 0.8 micrograms/m3 (0.3 ppb) for NDMA in 2 ml of diethylether extract. The laboratory operations studied included chemical synthesis, trace analysis, animal treatment, microbial mutagenesis tests and in vitro biochemical procedures. In most cases, nitrosamines were not detected in laboratory air, but levels of 200-800 micrograms/m3 (42 to 180 ppb) of N-nitrosomethyl-tert-butylamine were measured during animal treatment, 0.8-8.6 micrograms/m3 (0.3 to 2.8 ppb) of NDMA during mutagenesis assays, 12-22 micrograms/m3 (4-7 ppb) of NDMA during in vitro metabolism studies and 11 micrograms/m3 (3.6 ppb) of NDMA in a walk-in refrigerator. Appropriate corrective measures reduced all nitrosamine levels to below the detection limit. Hamsters and rats treated with NDAA (80 mg/kg, s.c.) excreted 4.4 and 12.9%, respectively, of the nitrosamine in expired air in 24 hr. This route of excretion may be metabolically significant and should be considered in the safe design of animal treatment and holding facilities.

  11. Analysis of personnel monitoring results of external radiation doses received by occupationally exposed workers obtained using CaSO4: Dy TLD personnel monitoring badges at RAPS (2000-2004)

    International Nuclear Information System (INIS)

    Chourasiya, G.; Kher, R.K.; Rao, B.S.; Pradhan, S.M.

    2006-01-01

    Personnel monitoring is a key step in radiation protection programme. It helps in keeping a check on radiation hazards and safety aspects of the operating unit. Moreover, analysis of the temporal trends in exposure histories of the individuals/groups play an important role in assessing the need of improved standards of protection and the impact of implementation of such measures. The paper presents the analysis of annual effective dose and collective dose to the radiation workers, which are indicators of individual risk and the impact of the practice. The present study also gives the analysis of the effective dose, cumulative dose and various dose distribution ratios (SR E and NR E ) for the block of 5 years (2000-2004) of RAPS 1 and 2 the oldest PHWR in the country and RAPS 3 and 4 the latest in the series incorporating many improvements in design and operation. It is seen that occupational exposures at NPPs have been showing a steadily decreasing trend, which is a result of a number of design improvements, operation and protection measures. However, to achieve world standards, we have to go a long way by further carrying out identification of areas of improvement, good operating practices along with the desired modifications in design. (author)

  12. Review of historical monitoring data on Techa River contamination

    Science.gov (United States)

    Vorobiova, M. I.; Degteva, M. O.; Burmistrov, D. S.; Safronova, N. G.; Kozheurov, V. P.; Anspaugh, L. R.; Napier, B. A.; Neta, P. I. (Principal Investigator)

    1999-01-01

    The Mayak Production Association was the first Russian site for the production and separation of plutonium. The extensive increase in plutonium production during 1948-1955, as well as the absence of reliable waste-management technology, resulted in significant releases of liquid radioactive effluent into the rather small Techa River. This resulted in chronic external and internal exposure of about 30,000 residents of riverside communities; these residents form the cohort of an epidemiologic investigation. Analysis of the available historical monitoring data indicates that the following reliable data sets can be used for reconstruction of doses received during the early periods of operation of the Mayak Production Association: Temporal pattern of specific beta activity of river water for several sites in the upper Techa region since July 1951; average annual values of specific beta activity of river water and bottom sediments as a function of downstream distance for the whole river since 1951; external gamma-exposure rates near the shoreline as a function of downstream distance for the whole Techa River since 1952; and external gamma-exposure rate as a function of distance from the shoreline for several sites in the upper and middle Techa since 1951.

  13. Individual monitoring program for internal contamination by inhaled uranium

    International Nuclear Information System (INIS)

    Vazquez, C.; Chapel, M.L.; Saenz Gancedo, R.

    1988-01-01

    The metabolic behaviour of inhaled uranium is studied. Using a particular analytical method applied to the models and dose assessment methods recommended by ICRP, the organ committed equivalent dose and effective equivalent dose are calculated. The exact ALI and DAC are derived from there. In the paper, the influence that various parameters have on those results are considered for the specific case of a particular nuclear element fabrication factory. Different AMAD and solubility type of inhaled material are specially analyzed. The results show the paramount importance of some of these parameters on the secondary and derived dose limits. Relationships between the real intake, as a fraction of ALI, and the lung retention or urine excretion are shown for different cases and intake forms hypothesis. Minimum detectable intakes with the available experimental techniques are then established. The results shown in the papel are a useful tool to help on the decision on the type and frequency of the individual monitoring techniques to be established in different circumstances. (Author)

  14. In Situ Monitoring of Groundwater Contamination Using the Kalman Filter For Sustainable Remediation

    Science.gov (United States)

    Schmidt, F.; Wainwright, H. M.; Faybishenko, B.; Denham, M. E.; Eddy-Dilek, C. A.

    2017-12-01

    Sustainable remediation - based on less intensive passive remediation and natural attenuation - has become a desirable remediation alternative at contaminated sites. Although it has a number of benefits, such as reduced waste and water/energy usage, it carries a significant burden of proof to verify plume stability and to ensure insignificant increase of risk to public health. Modeling of contaminant transport is still challenging despite recent advances in numerical methods. Long-term monitoring has, therefore, become a critical component in sustainable remediation. However, the current approach, which relies on sparse groundwater sampling, is problematic, since it could miss sudden significant changes in plume behavior. A new method is needed to combine existing knowledge about contaminant behavior and latest advances in in situ groundwater sensors. This study presents an example of the effective use of the Kalman filter approach to estimate contaminant concentrations, based on in situ measured water quality parameters (e.g. electrical conductivity and pH) along with the results of sparse groundwater sampling. The Kalman filter can effectively couple physical models and data correlations between the contaminant concentrations and in situ measured variables. We aim (1) to develop a framework capable of integrating different data types to provide accurate contaminant concentration estimates, (2) to demonstrate that these results remain reliable, even when the groundwater sampling frequency is reduced, and (3) to evaluate the future efficacy of this strategy using reactive transport simulations. This framework can also serve as an early warning system for detecting unexpected plume migration. We demonstrate our approach using historical and current groundwater data from the Savannah River Site (SRS) F-Area Seepage Basins to estimate uranium and tritium concentrations. The results show that the developed method can provide reliable estimates of contaminant

  15. First Results from Contamination Monitoring with the WFC3 UVIS G280 Grism

    Science.gov (United States)

    Rothberg, B.; Pirzkal, N.; Baggett, S.

    2011-11-01

    The presence of contaminants within the optical light path of the instrument or telescope can alter photometric zeropoints and the observed flux levels of imaging and spectra, particularly at UV wavelengths. Regular monitoring of a spectro-photometric standard star using photometric filters has been used in the past to monitor the presence of contaminants and (when necessary) re-calibrate zeropoints. However, the use of the WFC3 UVIS Grism mode (G280 filter) may provide a more robust early alert detection system for the presence of contaminants, in particular, those that are photo-polymerized from the bright Earth. These contaminants may collect on surfaces in the optical light path of the telescope. The G280 grism is sensitive to light at wavelengths below the cutoff of the bluest UV filter (F218W). In this ISR, we present: 1) the first results from G280 monitoring for the period of 2010-November through 2011-August; 2) the discovery of an anomaly in the WCS header information of sub-array exposures; and 3) an outline for reducing standard G280 grism observations and the specialized case of observations obtained in sub-array mode.

  16. Development and application of techniques for monitoring the bioremediation of petroleum hydrocarbon-contaminated soils

    International Nuclear Information System (INIS)

    Greer, C.; Hawar, J.; Samson, R.

    1994-01-01

    A series of tests was designed to examine bioremediation potential in soil and to monitor performance during the treatment operation. Physical and chemical characterization of the soil provides information on the types of organics, their concentrations, and whether interfering materials are present. Microbiological assessment involves culturing of bacterial populations in the soil and examination of the colonies to determine which have the genetic potential to degrade the soil contaminants. Catabolic gene probes are used to survey viable bacteria from petroleum hydrocarbon contaminated soils. Such soils consistently demonstrate the presence of bacteria possessing the genetic capability to degrade simple straight-chain alkanes and aromatics. Mineralization and respirometric studies are indicators of the biological activity in the soil, and can be directed at microbial activity towards specific substrates. Gene probe monitoring of a petroleum hydrocarbon contaminated soil during biopile treatment demonstrated that hydrocarbon-degrading bacterial numbers and activity were temperature dependent. The results showed that the activity of the indigenous bacteria as measured by hexadecane mineralization also correlated with the disappearance of the oil and grease. The application of this protocol has provided a useful means to screen contaminated soils for bacteria with desirable catabolic properties and to monitor pollutant-degrading bacteria during biotreatment. 15 refs., 10 figs

  17. Determination of contamination operational value by routine monitoring in research laboratories

    International Nuclear Information System (INIS)

    Salomao, Edeilson; Medeiros, Regina Bitelli; Mattos, Maria Fernanda S.S.; Daros, Kellen Adriana Curci

    2008-01-01

    The radioisotopes have a large spectrum of applicability in many areas of science, as in medicine, agriculture and industry in general. In the biological area, the radioisotopes have brought many benefits to study physiological processes in living organisms and in vitro. The most radioisotopes used in biological research are emitters of radiation of low energy, mainly β, and are used as unsealed sources. The manipulation of these radioisotopes generates radioactive wastes and eventually can cause contamination in the areas of handling or even occasionally in areas to which access is not controlled. According to CNEN-NE-3.02 standard is necessary and mandatory the exposure and contamination levels control in the areas of handling of unsealed sources. The goal of the work is to establish how often the monitoring should be done through the survey of the contamination and exposure levels, in areas designed to manipulate 32 P and how this monitoring can contribute to the improvement the conditions of radiological protection. From the twenty eight research laboratories registered by 'Nucleo de Protecao Radiologica' (NPR) were selected four where the activities are not restrict to 32 P biological assays. The levels of contamination and exposure were evaluated using monitors GM and the layout of laboratories containing the points to be tracker defined based on the researchers' routine. At each point three values were obtained to measure the rate of contamination on the surface and exposure rate. The measures were made twice a week before and after the radioisotope manipulation. Based on these data was possible to establish the range from 0,306 to 0,678 Bq.cm -2 as operational average level to the superficial contamination. The average exposure rate measured was 5.16 n C/Kg.h. The results were important to demonstrating to researchers how they can contribute to the improvement of radiological protection conditions. (author)

  18. Contaminant monitoring programmes using marine organisms: Quality assurance and good laboratory practice

    International Nuclear Information System (INIS)

    1990-01-01

    This publication provides guidelines for obtaining reliable and relevant data during monitoring programmes in which contaminants are measured in marine organisms. It describes the precautions to be taken in each of the procedural steps from planning and sampling to the publication of data reports. The purpose of this document is to provide general guidance on quality assurance and to outline the approach that could be taken by laboratories to achieve the specific aims(s) for each marine pollution monitoring programme. Since most laboratories are currently focussing on programmes involving marine organisms, this document will be confined to this aspect. Four main aims can be identified for programmes involving the collection and analysis of marine organisms for the three main groups of contaminants (metals, organochlorine compounds and petroleum hydrocarbons), these are: (i) The measurement of contaminant levels in edible marine organisms in relation to public health; (ii) The identification of heavily contaminated areas of the sea (''hot spots'') where levels of contaminants are at least an order of magnitude higher than levels in clean or uncontaminated areas; (iii) The establishment of present levels of contaminants in marine organisms (i.e., a ''baseline''); (iv) The assessment of changes in concentrations of contaminants in organisms over a period of time (trends). The selection of organisms will be dictated by the eating patterns of the population. These can be identified by a survey of the species sold at the market, by obtaining information from colleagues in government departments who deal with such matters or in the absence of such information, by distributing a questionnaire to a representative section of the general public. 9 refs, 4 figs

  19. Air monitoring data reveal previously unknown contamination at radioactive waste disposal area, Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    Kraig, D.H.; Conrad, R.C.

    2000-01-01

    Air monitoring at Area G, the low-level radioactive waste disposal area at Los Alamos National Laboratory, revealed increased air concentrations of 239 Pu and 241 Am at one location along the north boundary. This air monitoring location is a couple of meters north of a dirt road used to access the easternmost part of Area G. Air concentrations of 238 Pu were essentially unaffected which was puzzling because both 238 Pu and 239 Pu are present in the local, slightly contaminated soils. Air concentrations of these radionuclides increased about a factor of ten in early 1995 and remained at those levels until the first quarter of 1996. During the spring of 1996 air concentrations again increased by a factor of about ten. No other radionuclides were elevated, and no other Area G stations showed elevations of these radionuclides. After several formal meetings did not provide an adequate explanation for the elevations, a gamma-survey was performed and showed a small area of significant contamination just south of the monitor location. We found that in February 1995, a trench for a water line had been dug within a meter or so of the air stations. Then, during early 1996, the dirt road was rerouted such that its new path was directly over the unknown contamination. It appears that the trenching brought contaminated material to the surface and caused the firs rise in air concentrations and then the rerouting of the road over the contamination caused the second rise, during 1996. We also found that during 1976 and 1977 contaminated soils from the clean-up of an old processing facility had been spread over the filled pits in the vicinity of the air monitors. These soils, which were probably the source of the air contamination, were very low in 238 Pu which explains why we saw very little 238 Pu in the increased air concentrations. A layer of gravel and sand was spread over the contaminated area. Although air concentrations of 239 Pu and 241 Am dropped considerably, they have

  20. Estimating an appropriate sampling frequency for monitoring ground water well contamination

    International Nuclear Information System (INIS)

    Tuckfield, R.C.

    1994-01-01

    Nearly 1,500 ground water wells at the Savannah River Site (SRS) are sampled quarterly to monitor contamination by radionuclides and other hazardous constituents from nearby waste sites. Some 10,000 water samples were collected in 1993 at a laboratory analysis cost of $10,000,000. No widely accepted statistical method has been developed, to date, for estimating a technically defensible ground water sampling frequency consistent and compliant with federal regulations. Such a method is presented here based on the concept of statistical independence among successively measured contaminant concentrations in time

  1. Analyses of integrated aircraft cabin contaminant monitoring network based on Kalman consensus filter.

    Science.gov (United States)

    Wang, Rui; Li, Yanxiao; Sun, Hui; Chen, Zengqiang

    2017-11-01

    The modern civil aircrafts use air ventilation pressurized cabins subject to the limited space. In order to monitor multiple contaminants and overcome the hypersensitivity of the single sensor, the paper constructs an output correction integrated sensor configuration using sensors with different measurement theories after comparing to other two different configurations. This proposed configuration works as a node in the contaminant distributed wireless sensor monitoring network. The corresponding measurement error models of integrated sensors are also proposed by using the Kalman consensus filter to estimate states and conduct data fusion in order to regulate the single sensor measurement results. The paper develops the sufficient proof of the Kalman consensus filter stability when considering the system and the observation noises and compares the mean estimation and the mean consensus errors between Kalman consensus filter and local Kalman filter. The numerical example analyses show the effectiveness of the algorithm. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  2. Rapid monitoring of large groups of internally contaminated people following a radiation accident

    International Nuclear Information System (INIS)

    1994-05-01

    In the management of an emergency, it is necessary to assess the radiation exposures of people in the affected areas. An essential component in the programme is the monitoring of internal contamination. Existing fixed installations for the assessment of incorporated radionuclides may be of limited value in these circumstances because they may be inconveniently sited, oversensitive for the purpose, or inadequately equipped and staffed to cope with the large numbers referred to them. The IAEA considered it important to produce guidance on rapid monitoring of large groups of internally contaminated people. The purpose of this document is to provide Member States with an overview on techniques that can be applied during abnormal or accidental situations. Refs and figs

  3. Effective radiological contamination control and monitoring techniques in high alpha environments.

    Science.gov (United States)

    Funke, Kevin C

    2003-02-01

    In the decommissioning of a highly contaminated alpha environment, such as the one at Hanford's 233-S Plutonium Concentration Facility, one of the key elements of a successful radiological control program is an integrated safety approach. This approach begins with the job-planning phase where the scope of the work is described. This is followed by a brainstorming session involving engineering and craft to identify how to perform the work in a logical sequence of events. Once the brainstorming session is over, a Job Hazard Analysis is performed to identify any potential problems. Mockups are utilized to enable the craft to get hands on experience and provide feedback and ideas to make the job run smoother. Ideas and experience gained during mockups are incorporated into the task instruction. To assure appropriate data are used in planning and executing the job, our principal evaluation tools included lapel and workplace air sampling, plus continuous air monitors and frequent surveys to effectively monitor job progress. In this highly contaminated alpha environment, with contamination levels ranging from 0.3 Bq cm-2 to approximately 100,000 Bq cm-2 (2,000 dpm per 100 cm2 to approximately 600 million dpm per 100 cm2), with average working levels of 1,600-3,200 Bq cm-2 (10-20 million dpm per 100 cm2) without concomitant ambient radiation levels, control of the spread of contamination is key to keeping airborne levels As Low As Reasonably Achievable.

  4. Comparison of surface contamination monitors for in vivo measurement of {sup 131}I in thyroid

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, S.M.; Dantas, A.L.A.; Dantas, B.M., E-mail: salomao.marques@ymail.com [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    The routine handling of radiopharmaceuticals in nuclear medicine represents a significant risk of internal exposure to the staff. The IAEA recommends the implementation of monitoring plans for all workers subject to a risk of exposures above 1 mSv per year. However, in Brazil, such recommendation is practically unfeasible due to the lack of a sufficient number of qualified internal dosimetry services over the country. This work presents an alternative based on a simple and inexpensive methodology aimed to perform in-vivo monitoring of {sup 131}I in thyroid using portable surface contamination probes. All models evaluated showed suitable sensitivity for such application. (author)

  5. Comparison of surface contamination monitors for in vivo measurement of 131I in thyroid

    International Nuclear Information System (INIS)

    Oliveira, S.M.; Dantas, A.L.A.; Dantas, B.M.

    2015-01-01

    The routine handling of radiopharmaceuticals in nuclear medicine represents a significant risk of internal exposure to the staff. The IAEA recommends the implementation of monitoring plans for all workers subject to a risk of exposures above 1 mSv per year. However, in Brazil, such recommendation is practically unfeasible due to the lack of a sufficient number of qualified internal dosimetry services over the country. This work presents an alternative based on a simple and inexpensive methodology aimed to perform in-vivo monitoring of 131 I in thyroid using portable surface contamination probes. All models evaluated showed suitable sensitivity for such application. (author)

  6. The radioecological monitoring of the some water ecosystems of the contaminated districts of Belarus

    International Nuclear Information System (INIS)

    Khvalej, O.D.; Dackevich, P.I.; Komissarov, F.D.; Basharina, L.P.

    2002-01-01

    The main results of the long-term radioecological monitoring of the some water ecosystems of the contaminated districts of Belarus are presented. The main components of water ecosystem (water, suspensions, bottom sediments, water vegetation) were observed. The migration of Cs 137 and Sr 90 on the water-collection areas were investigated in detail. The tendency of Sr 90 increasing in the components of the surface water systems is observed

  7. Monitoring Exposure to Ebola and Health of U.S. Military Personnel Deployed in Support of Ebola Control Efforts - Liberia, October 25, 2014-February 27, 2015.

    Science.gov (United States)

    Cardile, Anthony P; Murray, Clinton K; Littell, Christopher T; Shah, Neel J; Fandre, Matthew N; Drinkwater, Dennis C; Markelz, Brian P; Vento, Todd J

    2015-07-03

    In response to the unprecedented Ebola virus disease (Ebola) outbreak in West Africa, the U.S. government deployed approximately 2,500 military personnel to support the government of Liberia. Their primary missions were to construct Ebola treatment units (ETUs), train health care workers to staff ETUs, and provide laboratory testing capacity for Ebola. Service members were explicitly prohibited from engaging in activities that could result in close contact with an Ebola-infected patient or coming in contact with the remains of persons who had died from unknown causes. Military units performed twice-daily monitoring of temperature and review of exposures and symptoms ("unit monitoring") on all persons throughout deployment, exit screening at the time of departure from Liberia, and post-deployment monitoring for 21 days at segregated, controlled monitoring areas on U.S. military installations. A total of 32 persons developed a fever during deployment from October 25, 2014, through February 27, 2015; none had a known Ebola exposure or developed Ebola infection. Monitoring of all deployed service members revealed no Ebola exposures or infections. Given their activity restrictions and comprehensive monitoring while deployed to Liberia, U.S. military personnel constitute a unique population with a lower risk for Ebola exposure compared with those working in the country without such measures.

  8. Monitoring of organic contaminants in sediments using low field proton nuclear magnetic resonance

    Science.gov (United States)

    Zhang, Chi; Rupert, Yuri

    2016-04-01

    The effective monitoring of soils and groundwater contaminated with organic compounds is an important goal of many environmental restoration efforts. Recent geophysical methods such as electrical resistivity, complex conductivity, and ground penetrating radar have been successfully applied to characterize organic contaminants in the subsurface and to monitor remediation process both in laboratory and in field. Low field proton nuclear magnetic resonance (NMR) is a geophysical tool sensitive to the molecular-scale physical and chemical environment of hydrogen-bearing fluids in geological materials and shows promise as a novel method for monitoring contaminant remediation. This laboratory research focuses on measurements on synthetic samples to determine the sensitivity of NMR to the presence of organic contaminants and improve understanding of relationships between NMR observables, hydrological properties of the sediments, and amount and state of contaminants in porous media. Toluene, a light non-aqueous phase liquid (LNAPL) has been selected as a representative organic contaminant. Three types of porous media (pure silica sands, montmorillonite clay, and various sand-clay mixtures with different sand/clay ratios) were prepared as synthetic sediments. NMR relaxation time (T2) and diffusion-relaxation (D - T2) correlation measurements were performed in each sediment saturated with water and toluene mixed fluid at assorted concentrations (0% toluene and 100% water, 1% toluene and 99% water, 5% toluene and 95% water, 25% toluene and 75% water, and 100% toluene and 0% water) to 1) understand the effect of different porous media on the NMR responses in each fluid mixture, 2) investigate the role of clay content on T2 relaxation of each fluid, 3) quantify the amount hydrocarbons in the presence of water in each sediment, and 4) resolve hydrocarbons from water in D - T2 map. Relationships between the compositions of porous media, hydrocarbon concentration, and hydraulic

  9. Monitoring for contaminants of emerging concern in drinking water using POCIS passive samplers.

    Science.gov (United States)

    Metcalfe, Chris; Hoque, M Ehsanul; Sultana, Tamanna; Murray, Craig; Helm, Paul; Kleywegt, Sonya

    2014-03-01

    Contaminants of emerging concern (CEC) have been detected in drinking water world-wide. The source of most of these compounds is generally attributed to contamination from municipal wastewater. Traditional water sampling methods (grab or composite) often require the concentration of large amounts of water in order to detect trace levels of these contaminants. The Polar Organic Compounds Integrative Sampler (POCIS) is a passive sampling technology that has been developed to concentrate trace levels of CEC to provide time-weighted average concentrations for individual compounds in water. However, few studies to date have evaluated whether POCIS is suitable for monitoring contaminants in drinking water. In this study, the POCIS was evaluated as a monitoring tool for CEC in drinking water over a period of 2 and 4 weeks with comparisons to typical grab samples. Seven "indicator compounds" which included carbamazepine, trimethoprim, sulfamethoxazole, ibuprofen, gemfibrozil, estrone and sucralose, were monitored in five drinking water treatment plants (DWTPs) in Ontario. All indicator compounds were detected in raw water samples from the POCIS in comparison to six from grab samples. Similarly, four compounds were detected in grab samples of treated drinking water, whereas six were detected in the POCIS. Sucralose was the only compound that was detected consistently at all five plants. The POCIS technique provided integrative exposures of CECs in drinking water at lower detection limits, while episodic events were captured via traditional sampling methods. There was evidence that the accumulation of target compounds by POCIS is a dynamic process, with adsorption and desorption on the sorbent occurring in response to ambient levels of the target compounds in water. CECs in treated drinking water were present at low ng L(-1) concentrations, which are not considered to be a threat to human health.

  10. Strategies for monitoring the emerging polar organic contaminants in water with emphasis on integrative passive sampling.

    Science.gov (United States)

    Söderström, Hanna; Lindberg, Richard H; Fick, Jerker

    2009-01-16

    Although polar organic contaminants (POCs) such as pharmaceuticals are considered as some of today's most emerging contaminants few of them are regulated or included in on-going monitoring programs. However, the growing concern among the public and researchers together with the new legislature within the European Union, the registration, evaluation and authorisation of chemicals (REACH) system will increase the future need of simple, low cost strategies for monitoring and risk assessment of POCs in aquatic environments. In this article, we overview the advantages and shortcomings of traditional and novel sampling techniques available for monitoring the emerging POCs in water. The benefits and drawbacks of using active and biological sampling were discussed and the principles of organic passive samplers (PS) presented. A detailed overview of type of polar organic PS available, and their classes of target compounds and field of applications were given, and the considerations involved in using them such as environmental effects and quality control were discussed. The usefulness of biological sampling of POCs in water was found to be limited. Polar organic PS was considered to be the only available, but nevertheless, an efficient alternative to active water sampling due to its simplicity, low cost, no need of power supply or maintenance, and the ability of collecting time-integrative samples with one sample collection. However, the polar organic PS need to be further developed before they can be used as standard in water quality monitoring programs.

  11. Capacity training for the personnel of radiation monitoring in metal recycling; Curso de capacitacion para el personal que realiza la vigilancia radiologica en el reciclaje de metales

    Energy Technology Data Exchange (ETDEWEB)

    Caveda Ramos, C.A.; Dominguez Ley, O., E-mail: caveda@cphr.edu.cu [Centro de Proteccion e Higiene de las Radiaciones, La Habana (Cuba)

    2013-07-01

    In this work it a course for training for the personnel involved in the radiation monitoring of metal recycling is presented. The contents were elaborated taken into account the IAEA recommendations for the development of capacity and training activities in radiological safety and in the Guide for the control of radioactive material in metal recycling. The program is divided in eleven parts and the duration time is two weeks. Among the main covered topics are the requirements for radiation monitoring in metal recycling; response to detection of radioactive material and effects of the ionizing radiation in man and environment.

  12. Long-term ERT monitoring of biogeochemical changes of an aged hydrocarbon contamination.

    Science.gov (United States)

    Caterina, David; Flores Orozco, Adrian; Nguyen, Frédéric

    2017-06-01

    Adequate management of contaminated sites requires information with improved spatio-temporal resolution, in particular to assess bio-geochemical processes, such as the transformation and degradation of contaminants, precipitation of minerals or changes in groundwater geochemistry occurring during and after remediation procedures. Electrical Resistivity Tomography (ERT), a geophysical method sensitive to pore-fluid and pore-geometry properties, permits to gain quasi-continuous information about subsurface properties in real-time and has been consequently widely used for the characterization of hydrocarbon-impacted sediments. However, its application for the long-term monitoring of processes accompanying natural or engineered bioremediation is still difficult due to the poor understanding of the role that biogeochemical processes play in the electrical signatures. For in-situ studies, the task is further complicated by the variable signal-to-noise ratio and the variations of environmental parameters leading to resolution changes in the electrical images. In this work, we present ERT imaging results for data collected over a period of two years on a site affected by a diesel fuel contamination and undergoing bioremediation. We report low electrical resistivity anomalies in areas associated to the highest contaminant concentrations likely due transformations of the contaminant due to microbial activity and accompanying release of metabolic products. We also report large seasonal variations of the bulk electrical resistivity in the contaminated areas in correlation with temperature and groundwater level fluctuations. However, the amplitude of bulk electrical resistivity variations largely exceeds the amplitude expected given existing petrophysical models. Our results suggest that the variations in electrical properties are mainly controlled by microbial activity which in turn depends on soil temperature and hydrogeological conditions. Therefore, ERT can be suggested as

  13. Long-term ERT monitoring of biogeochemical changes of an aged hydrocarbon contamination

    Science.gov (United States)

    Caterina, David; Flores Orozco, Adrian; Nguyen, Frédéric

    2017-06-01

    Adequate management of contaminated sites requires information with improved spatio-temporal resolution, in particular to assess bio-geochemical processes, such as the transformation and degradation of contaminants, precipitation of minerals or changes in groundwater geochemistry occurring during and after remediation procedures. Electrical Resistivity Tomography (ERT), a geophysical method sensitive to pore-fluid and pore-geometry properties, permits to gain quasi-continuous information about subsurface properties in real-time and has been consequently widely used for the characterization of hydrocarbon-impacted sediments. However, its application for the long-term monitoring of processes accompanying natural or engineered bioremediation is still difficult due to the poor understanding of the role that biogeochemical processes play in the electrical signatures. For in-situ studies, the task is further complicated by the variable signal-to-noise ratio and the variations of environmental parameters leading to resolution changes in the electrical images. In this work, we present ERT imaging results for data collected over a period of two years on a site affected by a diesel fuel contamination and undergoing bioremediation. We report low electrical resistivity anomalies in areas associated to the highest contaminant concentrations likely due transformations of the contaminant due to microbial activity and accompanying release of metabolic products. We also report large seasonal variations of the bulk electrical resistivity in the contaminated areas in correlation with temperature and groundwater level fluctuations. However, the amplitude of bulk electrical resistivity variations largely exceeds the amplitude expected given existing petrophysical models. Our results suggest that the variations in electrical properties are mainly controlled by microbial activity which in turn depends on soil temperature and hydrogeological conditions. Therefore, ERT can be suggested as

  14. Comparison of active and passive sampling strategies for the monitoring of pesticide contamination in streams

    Science.gov (United States)

    Assoumani, Azziz; Margoum, Christelle; Guillemain, Céline; Coquery, Marina

    2014-05-01

    The monitoring of water bodies regarding organic contaminants, and the determination of reliable estimates of concentrations are challenging issues, in particular for the implementation of the Water Framework Directive. Several strategies can be applied to collect water samples for the determination of their contamination level. Grab sampling is fast, easy, and requires little logistical and analytical needs in case of low frequency sampling campaigns. However, this technique lacks of representativeness for streams with high variations of contaminant concentrations, such as pesticides in rivers located in small agricultural watersheds. Increasing the representativeness of this sampling strategy implies greater logistical needs and higher analytical costs. Average automated sampling is therefore a solution as it allows, in a single analysis, the determination of more accurate and more relevant estimates of concentrations. Two types of automatic samplings can be performed: time-related sampling allows the assessment of average concentrations, whereas flow-dependent sampling leads to average flux concentrations. However, the purchase and the maintenance of automatic samplers are quite expensive. Passive sampling has recently been developed as an alternative to grab or average automated sampling, to obtain at lower cost, more realistic estimates of the average concentrations of contaminants in streams. These devices allow the passive accumulation of contaminants from large volumes of water, resulting in ultratrace level detection and smoothed integrative sampling over periods ranging from days to weeks. They allow the determination of time-weighted average (TWA) concentrations of the dissolved fraction of target contaminants, but they need to be calibrated in controlled conditions prior to field applications. In other words, the kinetics of the uptake of the target contaminants into the sampler must be studied in order to determine the corresponding sampling rate

  15. Sensitivity of radiation monitoring systems in Manila Ports in detecting contamination in foodstuff shipments

    International Nuclear Information System (INIS)

    Romallosa, Kristine Marie D.; Caseria, Estrella S.; Piquero, Ronald E.; Agustin, Jan Aldrich A.

    2011-01-01

    During the Fukushima Nuclear Power Plant accident in Japan, one of the Philippines' measures to protect the public from radiological hazards of the accident is by monitoring agricultural and food imports for radioactive contamination. In this study, the sensitivity of the mobile Radiation Monitoring System (RM) in Manila Ports in detecting contamination in incoming foodstuff shipments was determined. Large volume synthetic 137 Cs reference sources were used to determine the minimum detectable concentration (MDC) of the RMS. The reference sources have radioactivity concentrations that are comparable to the PNRI guidance level of 1000 Bg/kg for 137 Cs that is destined for general consumption. Results of the MDC measurements show that the RMS units are sensitive enough to detect radioactivity levels that are within the guidance levels provided that a) the minimum package lot is approximately 200 kg, b) the package is positioned at the detector side, and c) the alarm setting of RMS is as calibrated. It was therefore established that the RMS can be used to initially screen incoming foodstuff shipments of possible contamination and thereby help minimize potential radiation exposures to the public. (author)

  16. Long Term Remote Monitoring of TCE Contaminated Groundwater at Savannah River Site

    International Nuclear Information System (INIS)

    Duran, C.; Gudavalli, R.; Lagos, L.; Tansel, B.; Varona, J.; Allen, M.

    2004-01-01

    The purpose of this study was to develop a mobile self powered remote monitoring system enhanced for field deployment at Savannah River Site (SRS). The system used a localized power source with solar recharging and has wireless data collection, analysis, transmission, and data management capabilities. The prototype was equipped with a Hydrolab's DataSonde 4a multi-sensor array package managed by a Supervisory Control and Data Acquisition (SCADA) system, with an adequate pumping capacity of water samples for sampling and analysis of Trichloroethylene (TCE) in contaminated groundwater wells at SRS. This paper focuses on a study and technology development efforts conducted at the Hemispheric Center for Environmental Technology (HCET) at Florida International University (FIU) to automate the sampling of contaminated wells with a multi-sensor array package developed using COTS (Commercial Off The shelf) parts. Bladder pumps will pump water from different wells to the sensors array, water quality TCE indicator parameters are measured (i.e. pH, redox, ORP, DO, NO3 -, Cl-). In order to increase user access and data management, the system was designed to be accessible over the Internet. Remote users can take sample readings and collect data remotely over a web. Results obtained at Florida International University in-house testing and at a field deployment at the Savannah River Site indicate that this long term monitoring technique can be a feasible solution for the sampling of TCE indicator parameters at remote contaminated sites

  17. Monitoring pesticides residues and contaminants for some leafy vegetables at the market level

    International Nuclear Information System (INIS)

    Ibrahim, A. B. H.

    2004-03-01

    Pesticide residues and contaminants in selected leafy vegetables, namely (lettuce, garden rocket and salad onion) were monitored at market level in Riyadh City in Saudi Arabia, during the period june to july 2001. Fifteen samples of vegetables from the City vegetable market of Riyadh were collected and subjected to multi-pesticide residue detection and analysis by gas chromatography with mass spectrometer and electron capture detectors (GC/MS,ECD). Results of sample extracts analysis showed that the two vegetables of: garden rocket and salad onion contain pesticide residues and contaminants which have no Maximum Residue Limits (MRL) prescribed by Codex Alimentarius Commission (CAC) collaborate with World Health and Food and Agriculture Organizations (WHO/FAO). Whereas lettuce vegetable was found free of any identified pesticide residues or contaminants. Garden rocket was shown to contain dibutyl phthalate (0.04 ppm)-steryl chloride (0.02 ppm) tridecane (0.06 ppm)-hexadecane (0.07 ppm)-BIS (ethylhexyl) phthalate (0.006 ppm) and pyridinium, 1-hexyl chloride (0.01 ppm). The salad onion was found to contain 9-octadecanamide (0.13 ppm)-tridecane (0.15 ppm) and tetradecane (0.16 ppm). There are no established MRL s for these pesticides and contaminants detected in garden rocket and salad onion, although when impacts on human health were reviewed some of them were found probably hazardous. (Author)

  18. Design, construction and monitoring of temporary storage facilities for removed contaminants

    International Nuclear Information System (INIS)

    Saegusa, Hiromitsu; Funaki, Hironori; Kurikami, Hiroshi; Sakamoto, Yoshiaki; Tokizawa, Takayuki

    2013-01-01

    Since the Fukushima Daiichi nuclear power plant accident caused by the Tohoku Region Pacific Coast Earthquake on March 11, 2011, decontamination work has been conducted in the surrounding environment within the Fukushima prefecture. Removed contaminants including soil, grass and trees are to be stored safely at temporary storage facilities for up to three years, after which they will be transferred to a planned interim storage facility. The decontamination pilot project was carried out in both the restricted and planned evacuation areas in order to assess decontamination methods and demonstrate measures for radiation protection of workers. Fourteen temporary storage facilities of different technical specifications were designed and constructed under various topographic conditions and land use. In order to support the design, construction and monitoring of temporary storage facilities for removed contaminants during the full-scale decontamination within the prefecture of Fukushima, technical know-how obtained during the decontamination pilot project has been identified and summarized in this paper. (author)

  19. Present state of the monitoring for internal contamination at Tokai Research Establishment, Japan Atomic Energy Research Institute

    International Nuclear Information System (INIS)

    Akaishi, J.; Fukuda, H.; Mizushita, S.

    1980-01-01

    Results are presented of internal contamination surveys carried out since 1969 at Tokai Research Establishment. Routine monitoring sometimes revealed significant internal contamination for tritium workers, but almost never for others. The number of subjects for special monitoring varied according to the activities. In 1965, the number of subjects for special monitoring was nearly 300, due to a reactor repair that year. In recent years, the number or special monitoring has been several tens or so. With regard to special monitoring, the workers with significant internal contamination were less than 50%. The internal dose (50 years) estimated for the majority of subjects was of mrem order. During the past 15 years, only several cases of exposure of rem order were found. The highest dose experienced was about 4 rems ( 131 I thyroid) (U.K.)

  20. Exposure assessment of process-related contaminants in food by biomarker monitoring.

    Science.gov (United States)

    Rietjens, Ivonne M C M; Dussort, P; Günther, Helmut; Hanlon, Paul; Honda, Hiroshi; Mally, Angela; O'Hagan, Sue; Scholz, Gabriele; Seidel, Albrecht; Swenberg, James; Teeguarden, Justin; Eisenbrand, Gerhard

    2018-01-01

    Exposure assessment is a fundamental part of the risk assessment paradigm, but can often present a number of challenges and uncertainties. This is especially the case for process contaminants formed during the processing, e.g. heating of food, since they are in part highly reactive and/or volatile, thus making exposure assessment by analysing contents in food unreliable. New approaches are therefore required to accurately assess consumer exposure and thus better inform the risk assessment. Such novel approaches may include the use of biomarkers, physiologically based kinetic (PBK) modelling-facilitated reverse dosimetry, and/or duplicate diet studies. This review focuses on the state of the art with respect to the use of biomarkers of exposure for the process contaminants acrylamide, 3-MCPD esters, glycidyl esters, furan and acrolein. From the overview presented, it becomes clear that the field of assessing human exposure to process-related contaminants in food by biomarker monitoring is promising and strongly developing. The current state of the art as well as the existing data gaps and challenges for the future were defined. They include (1) using PBK modelling and duplicate diet studies to establish, preferably in humans, correlations between external exposure and biomarkers; (2) elucidation of the possible endogenous formation of the process-related contaminants and the resulting biomarker levels; (3) the influence of inter-individual variations and how to include that in the biomarker-based exposure predictions; (4) the correction for confounding factors; (5) the value of the different biomarkers in relation to exposure scenario's and risk assessment, and (6) the possibilities of novel methodologies. In spite of these challenges it can be concluded that biomarker-based exposure assessment provides a unique opportunity to more accurately assess consumer exposure to process-related contaminants in food and thus to better inform risk assessment.

  1. 1,4-Dioxane drinking water occurrence data from the third unregulated contaminant monitoring rule.

    Science.gov (United States)

    Adamson, David T; Piña, Elizabeth A; Cartwright, Abigail E; Rauch, Sharon R; Hunter Anderson, R; Mohr, Thomas; Connor, John A

    2017-10-15

    This study examined data collected from U.S. public drinking water supplies in support of the recently-completed third round of the Unregulated Contaminant Monitoring Rule (UCMR3) to better understand the nature and occurrence of 1,4-dioxane and the basis for establishing drinking water standards. The purpose was to evaluate whether the occurrence data for this emerging but federally-unregulated contaminant fit with common conceptual models, including its persistence and the importance of groundwater contamination for potential exposure. 1,4-Dioxane was detected in samples from 21% of 4864 PWSs, and was in exceedance of the health-based reference concentration (0.35μg/L) at 6.9% of these systems. In both measures, it ranked second among the 28 UCMR3 contaminants. Although much of the focus on 1,4-dioxane has been its role as a groundwater contaminant, the detection frequency for 1,4-dioxane in surface water was only marginally lower than in groundwater (by a factor of 1.25; pwater (pwater sources tend to be more dilute. Sampling from large systems increased the likelihood that 1,4-dioxane was detected by a factor of 2.18 times relative to small systems (pwater were highly associated with detections of other chlorinated compounds particularly 1,1-dichlorethane (odds ratio=47; pchlorinated solvent stabilizer. Based on aggregated nationwide data, 1,4-dioxane showed evidence of a decreasing trend in concentration and detection frequency over time. These data suggest that the loading to drinking water supplies may be decreasing. However, in the interim, some water supply systems may need to consider improving their treatment capabilities in response to further regulatory review of this compound. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Radioactive sources and contaminated materials in scrap: monitoring, detection and remedial actions

    International Nuclear Information System (INIS)

    Gallini, R.; Berna, V.; Bonora, A.; Santini, M.

    1999-01-01

    The scrap recycling in steel and other metal mills represents one of the most relevant activities in the Province of Brescia (Lombardy, Italy). In our Province more than 20 million tonnes of metal scrap are recycled every year by a melting process. Since 1990, many accidents which took place were caused by the unwanted melting of radioactive sources, that were probably hidden in metal scrap. In 1993, the Italian Government stated directives to monitor metal scrap imported from non-EC countries because of the suspicion of the illegal traffic of radioactive materials. In 1996, a law imposed the control of all metal scrap, regardless of their origins. Since 1993, our staff have controlled thousands of railway wagons and trucks. Approximately a hundred steel mills and foundries of aluminium, cooper, brass, etc. have also been controlled and many samples have been collected (flue dust, slag, finished products). During these controls, contaminated areas have been brought to light in two warehouses (Cs 137), in 6 companies (Cs 137 and Am 241), in two landfills of industrial waste (Cs 137) and in a quarry (Cs 137). Up to now the contaminated areas have been cleaned, except for the last one. About 150 radioactive sources on contaminated materials have been found in metal scrap. We found radioactive sources of Co 60, Ra 226, Ir 192, Kr 85, Am 241, while the contamination of metals was mainly due to Ra 226. The situation described above justifies an accurate control of the amount of scrap to reduce the risk of contamination of the workers in the working areas, in the environment and in the general public. (author)

  3. Borehole Calibration Facilities to Support Gamma Logging for Hanford Subsurface Investigation and Contaminant Monitoring - 13516

    International Nuclear Information System (INIS)

    McCain, R.G.; Henwood, P.D.; Pope, A.D.; Pearson, A.W.

    2013-01-01

    Repeated gamma logging in cased holes represents a cost-effective means to monitor gamma-emitting contamination in the deep vadose zone over time. Careful calibration and standardization of gamma log results are required to track changes and to compare results over time from different detectors and logging systems. This paper provides a summary description of Hanford facilities currently available for calibration of logging equipment. Ideally, all logging organizations conducting borehole gamma measurements at the Hanford Site will take advantage of these facilities to produce standardized and comparable results. (authors)

  4. Borehole Calibration Facilities to Support Gamma Logging for Hanford Subsurface Investigation and Contaminant Monitoring - 13516

    Energy Technology Data Exchange (ETDEWEB)

    McCain, R.G.; Henwood, P.D.; Pope, A.D.; Pearson, A.W. [S M Stoller Corporation, 2439 Robertson Drive, Richland, WA 99354 (United States)

    2013-07-01

    Repeated gamma logging in cased holes represents a cost-effective means to monitor gamma-emitting contamination in the deep vadose zone over time. Careful calibration and standardization of gamma log results are required to track changes and to compare results over time from different detectors and logging systems. This paper provides a summary description of Hanford facilities currently available for calibration of logging equipment. Ideally, all logging organizations conducting borehole gamma measurements at the Hanford Site will take advantage of these facilities to produce standardized and comparable results. (authors)

  5. Detection and Monitoring of E-Waste Contamination through Remote Sensing and Image Analysis

    Science.gov (United States)

    Garb, Yaakov; Friedlander, Lonia

    2015-04-01

    Electronic waste (e-waste) is one of today's fastest growing waste streams, and also one of the more problematic, as this end-of-life product contains precious metals mixed with and embedded in a variety of low value and potentially harmful plastic and other materials. This combination creates a powerful incentive for informal value chains that transport, extract from, and dispose of e-waste materials in far-ranging and unregulated ways, and especially in settings where regulation and livelihood alternatives are sparse, most notably in areas of India, China, and Africa. E-waste processing is known to release a variety of contaminants, such as heavy metals and persistent organic pollutants, including flame retardants, dioxins and furans. In several sites, where the livelihoods of entire communities are dependent on e-waste processing, the resulting contaminants have been demonstrated to enter the hydrological system and food chain and have serious health and ecological effects. In this paper we demonstrate for the first time the usefulness of multi-spectral remote sensing imagery to detect and monitor the release and possibly the dispersal of heavy metal contaminants released in e-waste processing. While similar techniques have been used for prospecting or for studying heavy metal contamination from mining and large industrial facilities, we suggest that these techniques are of particular value in detecting contamination from the more dispersed, shifting, and ad-hoc kinds of release typical of e-waste processing. Given the increased resolution and decreased price of multi-spectral imagery, such techniques may offer a remarkably cost-effective and rapidly responsive means of assessing and monitoring this kind of contamination. We will describe the geochemical and multi-spectral image-processing principles underlying our approach, and show how we have applied these to an area in which we have a detailed, multi-temporal, spatially referenced, and ground

  6. Monitoring of Plutonium Contaminated Solid Waste Streams. A technical guide to design and analysis of monitoring systems

    International Nuclear Information System (INIS)

    Birkhoff, G.

    1985-06-01

    The basic information on the Pu content in Pu Contaminated Materials (PCM) is the measurement of radiation emitted by Pu isotopes either spontaneously or due to irradiation by external neutron or gamma-sources. Requirements on measurement accuracy and detection limits should be defined by the operator of a Pu-handling facility in accordance with monitoring objectives in the very beginning of the planning of a monitoring system. Monitoring objectives reflect nuclear safety and radiological protection regulations and the needs for Pu-accountancy of nuclear materials management and safeguards. On considering the possibilities and limitations of radiometric techniques a solution of the monitoring problem is based on appropriate segregation and packaging procedures and records upon matrix and isotopic composition of PCM-items to be measured. The general interrelations between waste item characteristics and measurement uncertainty and detection limit are outlined in the first chapter which is addressed to the system planner. Chapter 2 is devoted to the attention of instrument developers and analysts. It presents in a general approach the correlations between the observed radiation leakage rate, respectively detection signal, and the generating source, e.g. Pu-isotopic content of the examined PCM item. Some practical measurement methods are reviewed and their limitations are indicated. The possible radiometric techniques based on detection of gamma rays from alpha decay (and 241 Am), neutrons from spontaneous fission and (α,n)-reaction and from induced fission reactions by neutron irradiation of Pu isotopes are presented. The measurement uncertainty of a single PCM item measurement is estimated on the basis of the uncertainty of the spatial distributions of source (Pu) and matrix materials. For the estimation of the cumulative error over a large collection of PCM items from a defined PCM-stream a probabilistic approach is suggested

  7. Monitoring of airborne contamination during the handling of technetium-99m and radioiodine

    International Nuclear Information System (INIS)

    Eadie, A.S.; Horton, P.W.; Hilditch, T.E.

    1980-01-01

    Measurements have been made using an air sampler to measure airborne radioactivity produced during the routine handling of large activities of technetium-99m, iodine-125 and iodine-131. The results indicate that 99 Tcsup(m) can be safely handled in environments without direct exhaust of the ventilated air but that 125 I and 131 I should always be handled in a ventilated environment such as a fume cupboard or a down-draught work-station of the total-exhaust type. Monitoring of thyroid uptake proves to be the most reliable means of monitoring airborne contamination by these radionuclides, but burdens and radiation doses for typical procedures are well within the maximum permissible limits of the Code of Practice for the Protection of Persons from Ionizing Radiation arising from Medical and Dental Use. (author)

  8. Alpha contamination assessment for D ampersand D activities: Monitoring inside glove boxes and vessels

    International Nuclear Information System (INIS)

    Rawool-Sullivan, M.W.; Bolton, R.D.; Conaway, J.G.; MacArthur, D.W.

    1996-02-01

    We have developed a new approach to glove box monitoring that involves drawing air out of one glove port through a detection grid that collects ions created in the air inside the glove box by ionizing radiation, especially alpha radiation. The charge deposited on the detection grid by the ions is measured with a sensitive electrometer. The air can be circulated back to the glove box through the other glove port, preventing contamination from leaving the glove box and detector system. Initial experiments using a mock-up constructed of sheet metal indicate that this technology provides the measurement technique needed to perform a defensible, non-invasive measurement of alpha contamination inside glove boxes destined for waste disposal. This can result in an enormous cost savings if a given glove box can be shown to fall into the catagory of Low-Level Waste rather than Trans-Uranic Waste. Considering that hundreds of glove boxes contaminated with plutonium will be taken out of service at various nuclear facilities over the next few years, the potential cost savings associated with disposal as LLW rather than TRU waste are substantial

  9. Status of contamination monitoring in radiation activities of National Atomic Energy Agency (NAEA) in Indonesia

    Energy Technology Data Exchange (ETDEWEB)

    Suhariyono, Gatot [National Atomic Energy Agency, Jakarta (Indonesia)

    1997-06-01

    National Atomic Energy Agency (NAEA) or Badan Tenaga Atom Nasional (BATAN) is a non departmental governmental agency, headed by a Director General who is directly responsible to the President. Center for Standardization and Radiation Safety Research (CSRSR) is one of the research centers within the deputy for the assessment of nuclear science and technology of the NAEA. The main task of the CSRSR is to implement research and development program, development and services in the field of radiation safety, standardization, dosimetry, radiation health as well as the application of nuclear techniques in medicine, according to the policy confirmed by the director general of BATAN. Task of radiation protection division is to set up programs and to develop radiation protection, personal monitoring system and radiation level of the working areas and their surroundings as well as dose limitation system, to carry out technical up grading of radiation protection officials skill and to help coping with radiation accident. The key factor on contamination monitoring is to reduce human error and mechanical failures. These problems can be achieved to the highest degree by developing knowledge and skill of staffs via trainings or courses on contamination and decontamination, so that they are hoped to become trained and qualified staffs. (G.K.)

  10. Geophysical Monitoring of Hydrocarbon-Contaminated Soils Remediated with a Bioelectrochemical System.

    Science.gov (United States)

    Mao, Deqiang; Lu, Lu; Revil, André; Zuo, Yi; Hinton, John; Ren, Zhiyong Jason

    2016-08-02

    Efficient noninvasive techniques are desired for monitoring the remediation process of contaminated soils. We applied the direct current resistivity technique to image conductivity changes in sandbox experiments where two sandy and clayey soils were initially contaminated with diesel hydrocarbon. The experiments were conducted over a 230 day period. The removal of hydrocarbon was enhanced by a bioelectrochemical system (BES) and the electrical potentials of the BES reactors were also monitored during the course of the experiment. We found that the variation in electrical conductivity shown in the tomograms correlate well with diesel removal from the sandy soil, but this is not the case with the clayey soil. The clayey soil is characterized by a larger specific surface area and therefore a larger surface conductivity. In sandy soil, the removal of the diesel and products from degradation leads to an increase in electrical conductivity during the first 69 days. This is expected since diesel is electrically insulating. For both soils, the activity of BES reactors is moderately imaged by the inverted conductivity tomogram of the reactor. An increase in current production by electrochemically active bacteria activity corresponds to an increase in conductivity of the reactor.

  11. Evaluation of natural attenuation processes in the groundwater of a tar oil contaminated site: development of a monitoring network

    International Nuclear Information System (INIS)

    Borke, P.; Husers, N.; Werner, P.; Leibenath, C.

    2005-01-01

    Tar oil is a complex mixture of mainly aromatic hydrocarbons. It is found in the subsurface of manufactured gas plants (MGP), coking plants or wood preserving facilities. The transportation into the soil and groundwater stands for a severe contamination. This is due to the physico-chemical properties of the DNAPL (dense non aqueous phase liquid) and its mobility in the soil and aquifer system. Additionally most of the contaminants show a low biological degradability and solubility under in situ conditions. Therefore it is known as a long term source of contamination. Nevertheless, natural attenuation (NA) processes are detectable at tar oil contaminated sites. In the thematic network two of the German funding priority KORA (http://www.natural-attenuation.de) these processes are matter of investigation. Four typical contaminated sites were chosen to evaluate under which circumstances monitored natural attenuation (MNA) is applicable. Furthermore enhanced natural attenuation questions are examined. The design of monitoring networks at tar oil contaminated sites plays a significant role in gaining field evidence for natural attenuation as well as documenting the efficiency of the attenuation processes and evaluating the matching of performance goals. Well designed monitoring networks include the placement of monitoring wells in 3D so that 3D flow path, mass balances and an estimation of mass flux can be monitored. As an example the history of the monitoring network of a wood preserving facility is shown. Starting from a risk assessment network to a network for MNA is presented. In this case for example especially the determination of the groundwater flow direction in time and space is connected to the number of observation wells and their location. Moreover in the beginning the observation wells were located according to the assumed centerline of the plume. Because of the variability of the groundwater flow direction and the need to determine mass flux a control plane

  12. Evaluation of the RSG-GAS Alpha-Beta Aerosol Contaminant Monitor Performance Under Reactor Operation Condition

    International Nuclear Information System (INIS)

    Hartoyo, Unggul; Setiawanto, Anto; Sumarno, Yulius

    2000-01-01

    Analysis to evaluate the RSG-GAS alpha-beta aerosol contaminant monitor performance was done. The high potential radiation working area such as in RSG-GAS is important to monitored for personal safety. Further it is necessary to assure that the system monitor is reliable enough under normal conditions as well as emergency condition. The method uses in this analysis are monitoring and comparing with the standard source. The standard course indicator and panel in main control room indicate that the result is 1 x 110 exp 9 Ci/m exp 3. Based on data monitor observation, the RSG-GAS alpha-beta aerosol contaminant monitor system under reactor operation condition has a good enough performance

  13. Aspects of optimization of the means and methods for monitoring of the Kozloduy NPP personnel functional state

    International Nuclear Information System (INIS)

    Pandov, E.; Popandreeva, A.; Dincheva, E.

    1993-01-01

    Equipment and methods for testing and evaluation of the physiological and psychological condition of the nuclear power plant operators are the subject of the paper. Reaction-meter, mnemoperceptioscope and the apparatus 'Sredets' have been developed and used in order to test the sensory-motor reactions, the short-term memory and the operation-related memory according to a list of test completion periods and number of mistakes. The strain on the nuclear reactor operators has been found to be greater than that of the personnel in dozens of other professions tested by the same methods. For sustaining the operators efficiency it is considered necessary to develop and implement: 1) fast screening method and equipment for an initial functional condition testing on application for important jobs; 2) methods for current recovery evaluation in connection to the working shift; 3) methods and instruments for a fast incidental functional condition control of the operating personnel. (R.Ts.)

  14. Caresoil: A multidisciplinar Project to characterize, remediate, monitor and evaluate the risk of contaminated soils in Madrid (Spain)

    Science.gov (United States)

    Muñoz-Martín, Alfonso; Antón, Loreto; Granja, Jose Luis; Villarroya, Fermín; Montero, Esperanza; Rodríguez, Vanesa

    2016-04-01

    Soil contamination can come from diffuse sources (air deposition, agriculture, etc.) or local sources, these last being related to anthropogenic activities that are potentially soil contaminating activities. According to data from the EU, in Spain, and particularly for the Autonomous Community of Madrid, it can be considered that heavy metals, toxic organic compounds (including Non Aqueous Phases Liquids, NAPLs) and combinations of both are the main problem of point sources of soil contamination in our community. The five aspects that will be applied in Caresoil Program (S2013/MAE-2739) in the analysis and remediation of a local soil contamination are: 1) the location of the source of contamination and characterization of soil and aquifer concerned, 2) evaluation of the dispersion of the plume, 3) application of effective remediation techniques, 4) monitoring the evolution of the contaminated soil and 5) risk analysis throughout this process. These aspects involve advanced technologies (hydrogeology, geophysics, geochemistry,...) that require new developing of knowledge, being necessary the contribution of several researching groups specialized in the fields previously cited, as they are those integrating CARESOIL Program. Actually two cases concerning hydrocarbon spills, as representative examples of soil local contamination in Madrid area, are being studied. The first is being remediated and we are monitoring this process to evaluate its effectiveness. In the second location we are defining the extent of contamination in soil and aquifer to define the most effective remediation technique.

  15. The Hamburg polonium-210 case. Monitoring of internal contaminations in a malevolent act

    International Nuclear Information System (INIS)

    Dalheimer, A.; Koenig, K.; Nosske, D.; Schaefer, I.

    2009-01-01

    The dead of Alexander Litvinenko in London in the late 2006 was linked with the visit of Dimitri Kovtun. So an investigation was started by the Hamburg Police. As the presence of polonium-210 was uncertain, the action was supported by the Federal Defense against Nuclear Hazards (NGA) of the Federal Office for Radiation Protection (BfS). Radiation measurements in some flats in Hamburg confirmed the suspicion of polonium-210 contaminations. As incorporations by ingestion or inhalation could not generally be excluded, the Coordinating Office on Incorporation Monitoring of the BfS (Leitstelle Inkorporationsueberwachung des BfS) was requested to clarify this issue. The BfS office then coordinated the required bioassay analyses of urine samples carried out at four officially appointed in-vitro laboratories for incorporation monitoring. The group of people to be examined included the members of the family involved living in the contaminated flats, the emergency forces, as well as potentially exposed members of the public. The calculation of the internal dose was based on standard assumptions and also conducted by the BfS. The internal radiation doses proved to be within the range of radiation doses due to natural exposures. Retrospectively it should be stressed that the collaboration and cooperation of all institutions involved in the operation in Hamburg was extremely good despite their differing organisational structures. As a result of the incident in Hamburg various middle and long-term measures have been taken since then by the BfS Coordinating Office on Incorporation Monitoring. (orig.)

  16. Monitoring of Urban Soil Contamination under Various Technogenic Impact: Comparison of the Two Seaside Cities

    Science.gov (United States)

    Miroshnychenko, Mykola; Krivitska, Ivetta; Hladkikh, Yevgenia

    2017-04-01

    The aim of the research was to show how the environmental policy of city can affect the quality of soils. Studies were carried out simultaneously in the two cities of Ukrainian coast of the Azov Sea, which are significantly different in terms of technogenic impact. Berdyansk is a well known resort and wellness center, but until recently around 30 petrochemical, machine-building and other enterprises were located there. The largest industrial center Mariupol, where emissions from enterprises to the atmosphere exceed 300 thousand tons per year, is located about 60 km from Berdyansk in similar natural conditions. Observations of soil contamination was performed on 60 monitoring sites not less than 2500 m2, located in industrial, administrative, cultural, residential and recreational zones of each city. The time series of observations: the first stage in 2002-2003, the second in 2007-2008, third in 2012-2014. The available forms of heavy metals in the soils were determined by atomic-absorption method after extraction of buffer solution with pH 4.8 as well as 1 N HCl. The content of mineral salts in a water extract was measured titrimetrically. The content of heavy metals in grass vegetation and phytotoxicity of soil was determined in 50% of monitoring sites. Since 2002-2003, the level of soil contamination in the industrial zones of Berdyansk gradually decreased, but heavy metals began accumulate in soils of residential, cultural and administrative areas, and especially, in recreation objects. Probably, this is related to the reduction of the industrial sector and the increase of resort and tourist business. Consequently, the content of cadmium, chromium, and nickel in soils is reduced, but the content of micronutrients (Zn, Cu, Mn) increases. Currently the contamination of plants becomes less so the quality of local agricultural products is improved. In contrast to this, due to the intensive activity of the enterprises of iron and steel industry in Mariupol the level

  17. Methodology for bioremediation monitoring of oil wastes contaminated soils by using vegetal bio indicators; Metodologia para monitoramento de biorremediacao de solos contaminados com residuos oleosos com bioindicadores vegetais

    Energy Technology Data Exchange (ETDEWEB)

    Nascimento Neto, Durval; Carvalho, Francisco Jose Pereira de Campos [Parana Univ., Curitiba, PR (Brazil). Curso de Pos-Graduacao em Ciencia do Solo]. E-mail: fjcampos@cce.ufpr.br

    1998-07-01

    This work studies the development of a methodology for the evaluation of the bioremediation status of oil waste contaminated soils, by using vegetal bioindicators for the bioremediation process monitoring, and evaluation of the environmental impacts on the contaminated areas.

  18. Evaluation of targeted and untargeted effects-based monitoring tools to assess impacts of contaminants of emerging concern on fish in the South Platte River, CO

    Science.gov (United States)

    Rivers in the arid Western United States face increasing influences from anthropogenic contaminants due to population growth, urbanization, and drought. To better understand and more effectively track the impacts of these contaminants, biologically-based monitoring tools are incr...

  19. Remediation of the Andreyev Bay naval base; present contamination status and future monitoring strategy

    International Nuclear Information System (INIS)

    Hustveit, Styrkaar; Sneve, Malgorzata K.; Reistad, Ole; Kiselev, Mikhail; Shandala, Natalya

    2008-01-01

    Full text: The Andreyev Bay shore technical base (STB) is a former naval installation and the largest nuclear legacy site in northwest Russia. Established in the late 50-ties and early 60-ties, this naval facility performed activities related to the refuelling of Soviet Northern Fleet nuclear-propelled vessels as well as being a temporary storage site for SNF and solid and liquid radioactive wastes (SRW and LRW) arising as a result of civilian and military nuclear-propelled vessels operations and maintenance. A large inventory of spent nuclear fuel (SNF) and radioactive waste (RAW) are located at the site, and since an accident in 1982 large amounts of radioactivity have been released from the storage facilities. Remediation of Andreyev STB has been the subject of international cooperation for many years. Great Britain, Italy, Norway, Sweden and the European Bank for Reconstruction and Development (EBRD) have collaborated with the Russian government to secure the site, improve the infrastructure at the site, plan for new management strategies/facilities for SNF and demolish old buildings that were deemed an environmental hazard. On the basis of an agreement between the Russian Federal State Enterprise 'SevRao' and the Norwegian Radiation Protection Authority (NRPA) a study to map the gamma dose rates and the surface radionuclide concentrations in the contaminated parts of the site, as well as an overview and general knowledge of the area regarding geological and hydrogeological conditions was performed in the period 2002-2004. The aim of the study was to enable the provision of more effective radiological protection for personnel undertaking future operations at the site and to assess the radiation dose hazards present at Andreyev STB and to clarify the risks associated with the existing contamination and the continued storage of spent fuel and radioactive waste at the site. The first phase of the Norwegian program to survey the Andreyev Bay provided the basis for

  20. Optimization of internal contamination monitoring programmes by studying uncertainties linked to dosimetric assessment

    International Nuclear Information System (INIS)

    Davesne, Estelle

    2010-01-01

    To optimise the protection of workers against ionizing radiations, the International Commission on Radiological Protection recommends the use of dose constraint and limits. To verify the compliance of the means of protection with these values when a risk of internal contamination exists, monitoring programmes formed of periodic bioassay measurements are performed. However, uncertainty in the dose evaluation arises from the variability of the activity measurement and from the incomplete knowledge of the exposure conditions. This uncertainty was taken into account by means of classical, Bayesian and possibilist statistics. The developed methodology was applied to the evaluation of the potential exposure during nuclear fuel preparation or mining; and to the analysis of the monitoring programme of workers purifying plutonium in AREVA NC La Hague reprocessing plant. From the measurement decision threshold, the minimum dose detectable (MDD) by the programme with a given confidence level can be calculated through the software OPSCI. It is shown to be a useful support in the optimisation of monitoring programmes when seeking a compromise between their sensitivity and their costs. (author)

  1. Evaluating Leaf and Canopy Reflectance of Stressed Rice Plants to Monitor Arsenic Contamination

    Directory of Open Access Journals (Sweden)

    Varaprasad Bandaru

    2016-06-01

    Full Text Available Arsenic contamination is a serious problem in rice cultivated soils of many developing countries. Hence, it is critical to monitor and control arsenic uptake in rice plants to avoid adverse effects on human health. This study evaluated the feasibility of using reflectance spectroscopy to monitor arsenic in rice plants. Four arsenic levels were induced in hydroponically grown rice plants with application of 0, 5, 10 and 20 µmol·L−1 sodium arsenate. Reflectance spectra of upper fully expanded leaves were acquired over visible and infrared (NIR wavelengths. Additionally, canopy reflectance for the four arsenic levels was simulated using SAIL (Scattering by Arbitrarily Inclined Leaves model for various soil moisture conditions and leaf area indices (LAI. Further, sensitivity of various vegetative indices (VIs to arsenic levels was assessed. Results suggest that plants accumulate high arsenic amounts causing plant stress and changes in reflectance characteristics. All leaf spectra based VIs related strongly with arsenic with coefficient of determination (r2 greater than 0.6 while at canopy scale, background reflectance and LAI confounded with spectral signals of arsenic affecting the VIs’ performance. Among studied VIs, combined index, transformed chlorophyll absorption reflectance index (TCARI/optimized soil adjusted vegetation index (OSAVI exhibited higher sensitivity to arsenic levels and better resistance to soil backgrounds and LAI followed by red edge based VIs (modified chlorophyll absorption reflectance index (MCARI and TCARI suggesting that these VIs could prove to be valuable aids for monitoring arsenic in rice fields.

  2. Monitored Natural Attenuation of ino9rganic Contaminants Treatability Study Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Crapse, K

    2004-05-19

    The identification and quantification of key natural attenuation processes for inorganic contaminants at D-Area is detailed herein. Two overarching goals of this evaluation of monitored natural attenuation (MNA) as a remediation strategy were (1) to better define the availability of inorganic contaminants as potential sources for transport to groundwater and uptake by environmental receptors and (2) to understand the site-specific mechanisms controlling attenuation of these inorganic contaminants through tandem geochemical and biological characterization. Data collected in this study provides input for more appropriate site groundwater transport models. Significant natural attenuation is occurring at D-Area as evidenced by relatively low aqueous concentrations of constituents of concern (COCs) (Be, Ni, U, and As) at all locations characterized and the decrease in groundwater concentrations with increasing distance from the source. The observed magnitude of decrease in groundwater concentrations of COCs with distance from the D-Area Coal Pile Runoff Basin (DCPRB) could not be accounted for by the modeled physical attenuation processes of dilution/dispersion. This additional attenuation, i.e., the observed difference between the groundwater concentrations of COCs and the modeled physical attenuation, is due to biogeochemical processes occurring at the D-Area. In tandem geochemical and microbiological characterization studies designed to evaluate the mechanisms contributing to natural attenuation, pH was the single parameter found to be most predictive of contaminant attenuation. The increasing pH with distance from the source is likely responsible for increased sorption of COCs to soil surfaces within the aquifer at D-Area. Importantly, because the sediments appear to have a high buffering capacity, the acid emanating from the DCPRB has been neutralized by the soil, and these conditions have led to large Kd values at the site. Two major types of soils are present at

  3. Comparison of two freshwater turtle species as monitors of radionuclide and chemical contamination: DNA damage and residue analysis

    International Nuclear Information System (INIS)

    Meyers-Schoene, L.; Shugart, L.R.; Beauchamp, J.J.; Walton, B.T.

    1993-01-01

    Two species of turtles that occupy different ecological niches were compared for their usefulness as monitors of freshwater ecosystems where both low-level radioactive and nonradioactive contaminants are present. The pond slider (Trachemys scripta) and common snapping turtle (Chelydra serpentina) were analyzed for the presence of 90 Sr, 137 Cs, 60 Co, and Hg, radionuclides and chemicals known to be present at the contaminated site, and single-strand breaks in liver DNA. The integrity of the DNA was examined by the alkaline unwinding assay, a technique that detects strand breaks as a biological marker of possible exposure to genotoxic agents. This measure of DNA damage was significantly increased in both species of turtles at the contaminated site compared with turtles of the same species at a reference site, and shows that contaminant-exposed populations were under more severe genotoxic stress than those at the reference site. The level of strand breaks observed at the contaminated site was high and in the range reported for other aquatic species exposed to deleterious concentrations of genotoxic agents such as chemicals and ionizing radiation. Statistically significantly higher concentrations of radionuclides and Hg were detected in the turtles from the contaminated area. Mercury concentrations were significantly higher in the more carnivorous snapping turtle compared with the slider; however, both species were effective monitors of the contaminants

  4. Application of GIS technologies to monitor secondary radioactive contamination in the Delegen mountain massif

    Science.gov (United States)

    Alipbeki, O.; Kabzhanova, G.; Kurmanova, G.; Alipbekova, Ch.

    2016-06-01

    The territory of the Degelen mountain massif is located within territory of the former Semipalatinsk nuclear test site and it is an area of ecological disaster. Currently there is a process of secondary radioactive contamination that is caused by geodynamic processes activated at the Degelen array, violation of underground hydrological cycles and as a consequence, water seepage into the tunnels. One of the methods of monitoring of geodynamic processes is the modern technology of geographic information systems (GIS), methods of satellite radar interferometry and high accuracy satellite navigation system in conjunction with radioecological methods. This paper discusses on the creation of a GIS-project for the Degelen array, facilitated by quality geospatial analysis of the situation and simulation of the phenomena, in order to maximize an objective assessment of the radiation situation in this protected area.

  5. The Mobile Surface Contamination Monitor II environmental radiological characterization utilizing GPS/GIS technologies

    International Nuclear Information System (INIS)

    Wendling, M.A.

    1993-05-01

    Time, cost, and most importantly quality of data are the three factors to measure the success of field radiological characterizations. The application of coupling radiation detection instrumentation to a GPS receiver has dramatically increased the data quality achievable compared to traditional environmental radiological survey methods. Improvements in verifying adequate spatial coverage of an area while collecting data and at,the same time reducing field time requirements can be realized. Data acquired during the recent implementation of the Mobile Surface Contamination Monitor 11 (MSCM-11) will be presented to demonstrate the advantages of this system over traditional radiological survey methods. The comparison will include time and manpower requirements. Linking the complimentary GPS, GIS and radiation detection technologies on a mobile tractor based platform has provided a tool to provide radiological characterization data faster, cheaper, and better to assist in the Environmental Restoration Mission of the Hanford Site

  6. Monitoring of radioactive contamination in food and the environment 1986-1998

    International Nuclear Information System (INIS)

    Liland, Astrid; Skuterud, Lavrans; Bergan, Tone; Forseth, Torbjoern; Gaare, Eldar; Hellstroem, Turid

    2001-01-01

    The results from the national monitoring of radioactive contamination in food and the environment 1986-1998 are presented. The average 137Cs concentration is decreasing in cow's and goat's milk, sheep, reindeer and fresh water fish. Pasture and fungi are, on the contrary, not showing a general decreasing trend. The radioactivity in food and humans has been decreasing since 1987. The effective dose from intake is estimated to 0.02 mSv for an average Norwegian in 1998. Vulnerable groups may have received doses up to 0.4 mSv. One cannot rule out the possibility that some individuals in these groups have received doses superior to 1 mSv/year. (Author)

  7. Monitoring Potential Transport of Radioactive Contaminants in Shallow Ephemeral Channels: FY2017

    Energy Technology Data Exchange (ETDEWEB)

    Mizell, Steve A. [Desert Research Inst. (DRI), Las Vegas, NV (United States); Campbell, Scott A. [Desert Research Inst. (DRI), Las Vegas, NV (United States); McCurdy, Greg [Desert Research Inst. (DRI), Las Vegas, NV (United States); Miller, Julianne J. [Desert Research Inst. (DRI), Las Vegas, NV (United States)

    2018-04-01

    The Desert Research Institute (DRI) is conducting a field assessment of the potential for contaminated soil to be transported from the Smoky Site Contamination Area (CA) as a result of storm runoff. This activity supports U.S. Department of Energy (DOE) Environmental Management Nevada Program (EM-NV) efforts to establish post-closure monitoring plans for the Smoky Site Soils Corrective Action Unit (CAU) 550. The work is intended to confirm the likely mechanism of transport and determine the meteorological conditions that might cause the movement of contaminated soils, as well as determine the particle size fraction that is most closely associated with transported radionuclide-contaminated soils. These data will facilitate the design of the appropriate post-closure monitoring program. In 2011, DRI installed a meteorological monitoring station on the west side of the Smoky Site CA and a hydrologic (runoff) monitoring station within the CA, near the east side. Air temperature, wind speed, wind direction, relative humidity, precipitation, solar radiation, barometric pressure, soil temperature, and soil water content are collected at the meteorological station. The maximum, minimum, and average or total values (as appropriate) for each of these parameters are recorded for each 10-minute interval. The maximum, minimum, and average water depth in the flume installed at the hydrology station are also recorded for every 10-minute interval. This report presents data collected from these stations during fiscal year (FY) 2017. During the FY2017 reporting period, the warmest months were June, July, and August and the coldest were December and January. Solar radiation showed the same seasonal trend, although the months with the most solar radiation were May and June. Monthly mean wind speeds were highest in the spring (April and May). Winds were generally from the southwest during the summer and from the northwest throughout the remainder of the year. The monthly average

  8. Monitoring of metallic contaminants in energy drinks using ICP-MS.

    Science.gov (United States)

    Kilic, Serpil; Cengiz, Mehmet Fatih; Kilic, Murat

    2018-03-09

    In this study, an improved method was validated for the determination of some metallic contaminants (arsenic (As), chromium (Cr), cadmium (Cd), lead (Pb), iron (Fe), nickel (Ni), copper (Cu), Mn, and antimony (Sb)) in energy drinks using inductive coupled plasma mass spectrometry (ICP-MS). The validation procedure was applied for the evaluation of linearity, repeatability, recovery, limit of detection, and quantification. In addition, to verify the trueness of the method, it was participated in an interlaboratory proficiency test for heavy metals in soft drink organized by the LGC (Laboratory of the Government Chemist) Standard. Validated method was used to monitor for the determination of metallic contaminants in commercial energy drink samples. Concentrations of As, Cr, Cd, Pb, Fe, Ni, Cu, Mn, and Sb in the samples were found in the ranges of 0.76-6.73, 13.25-100.96, 0.16-2.11, 9.33-28.96, 334.77-937.12, 35.98-303.97, 23.67-60.48, 5.45-489.93, and 0.01-0.42 μg L -1 , respectively. The results were compared with the provisional guideline or parametric values of the elements for drinking waters set by the WHO (World Health Organization) and EC (European Commission). As, Cd, Cu, and Sb did not exceed the WHO and EC provisional guideline or parametric values. However, the other elements (Cr, Pb, Fe, Ni, and Mn) were found to be higher than their relevant limits at various levels.

  9. Monitoring psychrotrophic lactic acid bacteria contamination in a ready-to-eat vegetable salad production environment.

    Science.gov (United States)

    Pothakos, Vasileios; Snauwaert, Cindy; De Vos, Paul; Huys, Geert; Devlieghere, Frank

    2014-08-18

    A study monitoring lactic acid bacteria contamination was conducted in a company producing fresh, minimally processed, packaged and ready-to-eat (RTE) vegetable salads (stored at 4°C) in order to investigate the reason for high psychrotrophic LAB levels in the products at the end of shelf-life. Initially, high microbial counts exceeding the established psychrotrophic thresholds (>10(7)-10(8)CFU/g) and spoilage manifestations before the end of the shelf-life (7days) occurred in products containing an assortment of sliced and diced vegetables, but within a one year period these spoilage defects became prevalent in the entire processing plant. Environmental sampling and microbiological analyses of the raw materials and final products throughout the manufacturing process highlighted the presence of high numbers of Leuconostoc spp. in halved and unseeded, fresh sweet bell peppers provided by the supplier. A combination of two DNA fingerprinting techniques facilitated the assessment of the species diversity of LAB present in the processing environment along with the critical point of their introduction in the production facility. Probably through air mediation and surface adhesion, mainly members of the strictly psychrotrophic species Leuconostoc gelidum subsp. gasicomitatum and L. gelidum subsp. gelidum were responsible for the cross-contamination of every vegetable handled within the plant. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Inspection and monitoring plan, contaminated groundwater seeps 317/319/ENE Area, Argonne National Laboratory

    International Nuclear Information System (INIS)

    1996-01-01

    During the course of completing the Resource Conservation and Recovery Act (RCRA) Facility Investigation (RFI) in the 317/319/East-Northeast (ENE) Area of Argonne National Laboratory-East (ANL-E), groundwater was discovered moving to the surface through a series of groundwater seeps. The seeps are located in a ravine approximately 600 ft south of the ANL-E fence line in Waterfall Glen Forest Preserve. Samples of the seep water were collected and analyzed for selected parameters. Two of the five seeps sampled were found to contain detectable levels of organic contaminants. Three chemical species were identified: chloroform (14--25 microg/L), carbon tetrachloride (56--340 microg/L), and tetrachloroethylene (3--6 microg/L). The other seeps did not contain detectable levels of volatile organics. The nature of the contaminants in the seeps will also be monitored on a regular basis. Samples of surface water flowing through the bottom of the ravine and groundwater emanating from the seeps will be collected and analyzed for chemical and radioactive constituents. The results of the routine sampling will be compared with the concentrations used in the risk assessment. If the concentrations exceed those used in the risk assessment, the risk calculations will be revised by using the higher numbers. This revised analysis will determine if additional actions are warranted

  11. Global styrene oligomers monitoring as new chemical contamination from polystyrene plastic marine pollution.

    Science.gov (United States)

    Kwon, Bum Gun; Koizumi, Koshiro; Chung, Seon-Yong; Kodera, Yoichi; Kim, Jong-Oh; Saido, Katsuhiko

    2015-12-30

    Polystyrene (PS) plastic marine pollution is an environmental concern. However, a reliable and objective assessment of the scope of this problem, which can lead to persistent organic contaminants, has yet to be performed. Here, we show that anthropogenic styrene oligomers (SOs), a possible indicator of PS pollution in the ocean, are found globally at concentrations that are higher than those expected based on the stability of PS. SOs appear to persist to varying degrees in the seawater and sand samples collected from beaches around the world. The most persistent forms are styrene monomer, styrene dimer, and styrene trimer. Sand samples from beaches, which are commonly recreation sites, are particularly polluted with these high SOs concentrations. This finding is of interest from both scientific and public perspectives because SOs may pose potential long-term risks to the environment in combination with other endocrine disrupting chemicals. From SOs monitoring results, this study proposes a flow diagram for SOs leaching from PS cycle. Using this flow diagram, we conclude that SOs are global contaminants in sandy beaches around the world due to their broad spatial distribution. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Tipified conditions for irradiation of equipment and personnel and gamma radiation spectral-angular parameters of radioactively contaminated area of the Chernobyl' accident

    International Nuclear Information System (INIS)

    Melent'ev, A.B.; Frid, E.S.; Shekhanov, G.A.; Zhitnik, A.K.; Shanenko, A.A.

    1992-01-01

    The analysis and calculated-experimental investigations were presented. The tipified conditions for irradiation of the equipment and the personnel as the result of destroys in the Chernobyl' NPP and initial data of spectral-angular parameters of gamma radiated sites were proposed. The results of the investigation may be used in the prediction of radiation effect on the personnel as well as during design and estimation of the effective protection from gamma radiation. 3 refs.; 7 refs

  13. Radioactivity monitoring and import regulation of the contaminated foodstuffs in Japan following the Chernobyl nuclear power plant accident

    International Nuclear Information System (INIS)

    Izumo, Yoshiro

    1997-01-01

    Radioactivity monitoring and import regulation of the contaminated foodstuffs executed by Minstry of Health and Welfare following the Chernobyl nuclear plant accident were reviewed as follows; 1) background of socio-psychological effects and environmental radioactivity leading to the regulation (to may 3, 1986); 2) intial intervention for imported foodstuffs in Japan (may 8, '86), and 3) in european countries (to may 31, '86), immediately after the Accident, respectively; 4) determination of the interim driven intervention level for radionuclides in imported foodstuffs (( 134 Cs + 137 Cs): 370 Bq/Kg) and activation of the monitoring, 5) outline of the monitoring with elapsed time, number of foodstuffs monitored, number of foodstuffs exceeded radioactivity of the intervention level and re-exported; 6) guideline in international trade of radioactive contaminated foodstuffs adopted by CODEX Alimentarius Commission (FAO/WHO) and the intervention level recommended by ICRP following the Accident; 7) discussion for problems and scopes in future based on the results of monitoring. As the results, a number of imported foodstuffs (about 75,000 samples at present) has been monitored, 55 samples exceeding the interim intervention level were re-exported to each export's country, and socio-psychological doubts for radioactive contamination of imported foodstuffs have been dispersed. In addition, problems for several factors based on calculation of the interim intervention level, radioactivity level of foodstuffs exceeding about 50 Bq/Kg as radiocesiums and necessity of monitoring for the other radionuclides in foods except radiocesiums were also discussed. (author)

  14. Radioactivity monitoring and import regulation of the contaminated foodstuffs in Japan following the Chernobyl nuclear power plant accident

    Energy Technology Data Exchange (ETDEWEB)

    Izumo, Yoshiro [Institute of Public Health, Tokyo (Japan)

    1997-03-01

    Radioactivity monitoring and import regulation of the contaminated foodstuffs executed by Minstry of Health and Welfare following the Chernobyl nuclear plant accident were reviewed as follows; (1) background of socio-psychological effects and environmental radioactivity leading to the regulation (to may 3, 1986); (2) intial intervention for imported foodstuffs in Japan (may 8, `86), and (3) in european countries (to may 31, `86), immediately after the Accident, respectively; (4) determination of the interim driven intervention level for radionuclides in imported foodstuffs (({sup 134}Cs + {sup 137}Cs): 370 Bq/Kg) and activation of the monitoring, (5) outline of the monitoring with elapsed time, number of foodstuffs monitored, number of foodstuffs exceeded radioactivity of the intervention level and re-exported; (6) guideline in international trade of radioactive contaminated foodstuffs adopted by CODEX Alimentarius Commission (FAO/WHO) and the intervention level recommended by ICRP following the Accident; (7) discussion for problems and scopes in future based on the results of monitoring. As the results, a number of imported foodstuffs (about 75,000 samples at present) has been monitored, 55 samples exceeding the interim intervention level were re-exported to each export`s country, and socio-psychological doubts for radioactive contamination of imported foodstuffs have been dispersed. In addition, problems for several factors based on calculation of the interim intervention level, radioactivity level of foodstuffs exceeding about 50 Bq/Kg as radiocesiums and necessity of monitoring for the other radionuclides in foods except radiocesiums were also discussed. (author)

  15. Personnel dose assignment practices

    International Nuclear Information System (INIS)

    Fix, J.J.

    1993-04-01

    Implementation of DOE N 5480.6 Radiological Control Manual Article 511(3) requirements, to minimize the assignment of personnel dosimeters, should be done only under a broader context ensuring that capabilities are in place to monitor and record personnel exposure both for compliance and for potential litigation. As noted in NCRP Report No. 114, personnel dosimetry programs are conducted to meet four major objectives: radiation safety program control and evaluation; regulatory compliance; epidemiological research; and litigation. A change to Article 511(3) is proposed that would require that minimizing the assignment of personnel dosimeters take place only following full evaluation of overall capabilities (e.g., access control, area dosimetry, etc.) to meet the NCRP objectives

  16. PCDDF and pesticides monitoring in a dioxin contaminated area in Rio de Janeiro - Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Carvalhaes, G.; Azevedo, J.A.; Azevedo, G.; Machado, M.; Brooks, P. [Analytical Solutions, Rio de Janeiro (Brazil)

    2004-09-15

    During the 40's and 50's there had been a hexachlorocyclohexane(HCH) industry in Duque de Caxias, state of Rio de Janeiro, Brazil. Duque de Caxias is a very important borough within the state's political and administrative structure. It is located in a strategic point connecting Minas Gerais and Rio de Janeiro. It also holds one of Brazil's greatest petroleum refineries. For 20 years, this factory (which is located next to an orphanage called Cidade dos Meninos, an area belonging to the Ministry of Social Assistance) produced thousands of tons of HCH and also other pesticides, such as DDT, DDD and DDE. In the beginning of the 60's, the industry had its activities stopped1. In 1989, significant amounts of HCH had been found by local inspectors in Duque de Caxias, where it had been being sold for use in agriculture. Once the product's usage had already been prohibited in Brazil, after a investigation authorities found that it would come from the inactive industry. Both environmental and public health institutions decided to use a mixture of lime and soil, in order to destroy the residues and organic compounds found in the old plant. Such procedure would cause a greater problem, for the lime used wouldn't meet the right proportions of the large area and its contaminated soil. In addition, it also affected the water supply and the local population. The consequences have been disastrous. Data referring to breastfeeding and blood revealed alarming pesticide rates that endangered the local people health conditions both in short and long term. After 14 years, monitoring is still necessary in that region so it is possible to control contamination and its damage related to secondary reactions, climatic effects and soil structure. For this reason, a monitoring program has been developed in order to investigate the rates of certain pesticides and PCDD/F in locations near the contamination field.

  17. Sentinel Wraps: Real-Time Monitoring of Food Contamination by Printing DNAzyme Probes on Food Packaging.

    Science.gov (United States)

    Yousefi, Hanie; Ali, M Monsur; Su, Hsuan-Ming; Filipe, Carlos D M; Didar, Tohid F

    2018-04-24

    Here, we report the development of a transparent, durable, and flexible sensing surface that generates a fluorescence signal in the presence of a specific target bacterium. This material can be used in packaging, and it is capable of monitoring microbial contamination in various types of food products in real time without having to remove the sample or the sensor from the package. The sensor was fabricated by covalently attaching picoliter-sized microarrays of an E. coli-specific RNA-cleaving fluorogenic DNAzyme probe (RFD-EC1) to a thin, flexible, and transparent cyclo-olefin polymer (COP) film. Our experimental results demonstrate that the developed (RFD-EC1)-COP surface is specific, stable for at least 14 days under various pH conditions (pH 3-9), and can detect E. coli in meat and apple juice at concentrations as low as 10 3 CFU/mL. Furthermore, we demonstrate that our sensor is capable of detecting bacteria while still attached to the food package, which eliminates the need to manipulate the sample. The developed biosensors are stable for at least the shelf life of perishable packaged food products and provide a packaging solution for real-time monitoring of pathogens. These sensors hold the potential to make a significant contribution to the ongoing efforts to mitigate the negative public-health-related impacts of food-borne illnesses.

  18. Demolition and removal of radioactively contaminated concrete soil: Aerosol control and monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Newton, G.J.; Hoover, M.D.; Grace, A.C. III

    1995-12-01

    From 1963 to 1985, two concrete-lined ponds were used to reduce the volume of radioactive liquids from the Institute`s research programs. Following withdrawal of the {open_quotes}hot ponds{close_quotes} from active use, the residual sludges and plastic liners of the ponds were removed and shipped to a radioactive waste disposal site. From 1987 to 1994, the concrete structures remained undisturbed pending environmental restoration on the site. Restoration began in 1994 and was completed in 1995. Restoration involved mechanical breakup and removal of the concrete structures and removal of areas of contaminated soils from the site. This report describes the design and results of the aerosol control and monitoring program that was conducted to ensure protection of workers and the environment during the restoration process. The aerosol control and monitoring strategy developed for remediation of the ITRI hot ponds was successful both in preventing dispersion of radioactive dusts and in demonstrating that exposures of workers and offsite releases were within statutory limits.

  19. Ecotoxicity monitoring and bioindicator screening of oil-contaminated soil during bioremediation.

    Science.gov (United States)

    Shen, Weihang; Zhu, Nengwu; Cui, Jiaying; Wang, Huajin; Dang, Zhi; Wu, Pingxiao; Luo, Yidan; Shi, Chaohong

    2016-02-01

    A series of toxicity bioassays was conducted to monitor the ecotoxicity of soils in the different phases of bioremediation. Artificially oil-contaminated soil was inoculated with a petroleum hydrocarbon-degrading bacterial consortium containing Burkholderia cepacia GS3C, Sphingomonas GY2B and Pandoraea pnomenusa GP3B strains adapted to crude oil. Soil ecotoxicity in different phases of bioremediation was examined by monitoring total petroleum hydrocarbons, soil enzyme activities, phytotoxicity (inhibition of seed germination and plant growth), malonaldehyde content, superoxide dismutase activity and bacterial luminescence. Although the total petroleum hydrocarbon (TPH) concentration in soil was reduced by 64.4%, forty days after bioremediation, the phytotoxicity and Photobacterium phosphoreum ecotoxicity test results indicated an initial increase in ecotoxicity, suggesting the formation of intermediate metabolites characterized by high toxicity and low bioavailability during bioremediation. The ecotoxicity values are a more valid indicator for evaluating the effectiveness of bioremediation techniques compared with only using the total petroleum hydrocarbon concentrations. Among all of the potential indicators that could be used to evaluate the effectiveness of bioremediation techniques, soil enzyme activities, phytotoxicity (inhibition of plant height, shoot weight and root fresh weight), malonaldehyde content, superoxide dismutase activity and luminescence of P. phosphoreum were the most sensitive. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Combining Geoelectrical Measurements and CO 2 Analyses to Monitor the Enhanced Bioremediation of Hydrocarbon-Contaminated Soils: A Field Implementation

    OpenAIRE

    Noel , Cécile; Gourry , Jean-Christophe; Deparis , Jacques; Blessing , Michaela; Ignatiadis , Ioannis; Guimbaud , Christophe

    2016-01-01

    International audience; Hydrocarbon-contaminated aquifers can be successfully remediated through enhanced biodegradation. However, in situ monitoring of the treatment by piezometers is expensive and invasive and might be insufficient as the information provided is restricted to vertical profiles at discrete locations. An alternative method was tested in order to improve the robustness of the monitoring. Geophysical methods, electrical resistivity (ER) and induced polarization (IP), were combi...

  1. Understanding transport pathways in a river system - Monitoring sediments contaminated by an incident

    Science.gov (United States)

    Dietrich, S.; Kleisinger, C.; Hillebrand, G.; Claus, E.; Schwartz, R.; Carls, I.; Winterscheid, A.; Schubert, B.

    2016-12-01

    Experiments to trace transport of sediments and suspended particulate matter on a river scale are an expensive and difficult venture, since it causes a lot of official requirements. In spring 2015, polychlorinated biphenyls (PCB) were released during restoration works at a bridge in the upper part of the Elbe River, near the Czech-German border. In this study, the particle-bound PCB-transport is applied as a tracer for monitoring transport pathways of suspended solids (SS) along a whole river stretch over 700 km length. The incident was monitored by concentration measurements of seven indicator PCB congeners along the inland part of the Elbe River as well as in the Elbe estuary. Data from 15 monitoring stations (settling tanks) as well as from two longitudinal campaigns (grab samples) along the river in July and August 2015 are considered. The total PCB load is calculated for all stations on the basis of monthly contaminant concentrations and daily suspended sediment concentrations. Monte-Carlo simulations assess the uncertainties of the calculated load. 1D water levels and GIS analysis were used to locate temporal storage areas for the SS. It is shown that the ratio of high versus low chlorinated PCB congeners is a suitable tracer to distinguish the PCB load of the incident from the long-term background signal. Furthermore, the reduction of total PCB load within the upper Elbe indicates that roughly 24% of the SS were transported with the water by wash load. Approximately 600 km downstream of the incident site, the PCB-marked wash load was first identified in July 2015. PCB load transported intermittently in suspension was detected roughly 400 km downstream of the incident site by August 2015. In the Elbe Estuary, PCB-marked SS were only found upstream of the steep slope of water depth (approx. 4 to 15 m) within Hamburg harbor that acts as a major sediment sink. Here, SS from the inland Elbe are mixed with lowly contaminated marine material, which may mask the

  2. Evaluation of the homogeneity of reference flat sources used in calibration of surface contamination monitors

    International Nuclear Information System (INIS)

    Silva Junior, I.A.; Xavier, M.; Siqueira, P.T.D.; Potiens, M.P.A.

    2014-01-01

    The aim of this study was to re-evaluate the uniformity of the wide area reference sources of the Calibration Laboratory of Instruments (LCI-IPEN) used in the calibration of surface contamination monitors, according the recommendations of the ISO 8769 standard and the NRPB. In this work used six wide area reference sources of 150 cm 2 of 241 Am, 14 C, 36 Cl, 137 Cs, 90 Sr+ 90 Y and 99 Tc with reference dates between 1996 and 1997 and three sources of 100 cm 2 of 14 C, 137 Cs and 60 Co were used with reference dates 2007. Measurements were performed with a radiation monitor of the Thermo, model FH40GX with a pancake probe, model FHZ732GM. We also made several models on paper with the objective of define each measurement position and an aluminum plate with a square hole (6.25 cm 2 ) in its center, allowing the passage of the radiation only through the hole. Each wide area reference source was positioned in setup and measurements were performed in order to cover the entire surface of the source. The values of the uniformity obtained partially confirm previous data obtained in another study conducted by LCI-IPEN, showing that some wide area reference sources 150 cm 2 in disagree with ISO 8769. In the former work, just the source of 241 Am (7.3%) was within the range specified by the standard, now have sources of 241 Am (5.7%), 137 Cs (8.8%), 90 Sr+ 9 '0Y (8, 8%) and 99 Tc (9.2%) with values within the specified uniformity. The sources of 14 C (53.3%) and 36 Cl (16.6%) were outside the specified. The wide area reference sources of 100 cm 2 , show disagreement in values of uniformity of the sources 14 C (46.7%) and 60 Co (10.4%). The values of the uniformity of the wide area reference sources show that some fonts can not be used in calibrations, because not in accordance with the value of uniformity specified in ISO 8769:2010, this is a conditions to believe a laboratory according to ISO 17025, show the laboratory performs its services with a high quality. The

  3. Personnel Preparation.

    Science.gov (United States)

    Fair, George, Ed.; Stodden, Robert, Ed.

    1981-01-01

    Three articles comprise a section on personnel preparation in vocational education. Articles deal with two inservice programs in career/vocational education for the handicapped and a project to train paraprofessionals to assist special educators in vocational education. (CL)

  4. Application Of The SPV-based Surface Lifetime Technique To In-Line Monitoring Of Surface Cu Contamination

    Science.gov (United States)

    D'Amico, John; Savtchouk, Alexandre; Wilson, Matthew; Kim, Chul Hong; Yoo, Hyung Won; Lee, Chang Hwan; Kim, Tae Kyoung; Son, Sang Hoon

    2009-09-01

    Implementation of Cu interconnects into Silicon Integrated Circuits (IC's) has been instrumental in the continuing improvement of IC device performance. Copper as a well known Gate Oxide Integrity (GOI) killer [1, 2] requires extensive protocols to minimize the possibility of cross contamination. Despite such protocols the risk for cross contamination exists, and consequently there is the need for in-line Cu cross-contamination detection metrology. Preferably the metrology will be non-destructive, fast, and capable of mapping on product wafers. Up to now the most common approaches for monitoring Cu contamination in IC fabrication lines either measure Cu in the bulk Si, which is not applicable to Cu cross-contamination monitoring because Back-End-of-the-Line thermal budgets restrict the ability to diffuse the surface Cu into the bulk Si; or the techniques are not optimal for in-line monitoring due to their destructive, time-consuming, or costly nature. In this work we demonstrate for the first time the application of the ac-Surface Photo Voltage (ac-SPV) surface lifetime approach [3] to in-line, full wafer coverage mapping of low level (metrology system. Furthermore, because the metrology is non-contact (utilizing edge-grip handling) and non-destructive, it is directly applicable to measurement of production wafers. In-line fab data acquired using this metrology is presented and compared to data from Inductively Coupled Plasma Mass Spectroscopy (ICP-MS).

  5. On indoor radon contamination monitoring with SSNTDs: Experimental results concerning plate-out and self-plate-out effects

    International Nuclear Information System (INIS)

    Bigazzi, G.; Hadler, J.C.; Paulo, S.R.

    1989-01-01

    Measurements of the alpha activities of 222 Rn and its daughters were performed, both inside a glass recipient and in closed rooms, employing SSNTDs (CR-39 and nuclear emulsion). The experimental results presented here show that plate-out and self-plate-out effects should be taken into account when SSNTDs are employed in indoor radon contamination monitoring. (orig.)

  6. Contamination of estuaries from failing septic tank systems: difficulties in scaling up from monitored individual systems to cumulative impact.

    Science.gov (United States)

    Geary, Phillip; Lucas, Steven

    2018-02-03

    Aquaculture in many coastal estuaries is threatened by diffuse sources of runoff from different land use activities. The poor performance of septic tank systems (STS), as well as runoff from agriculture, may contribute to the movement of contaminants through ground and surface waters to estuaries resulting in oyster contamination, and following their consumption, impacts to human health. In monitoring individual STS in sensitive locations, it is possible to show that nutrients and faecal contaminants are transported through the subsurface in sandy soils off-site with little attenuation. At the catchment scale however, there are always difficulties in discerning direct linkages between failing STS and water contamination due to processes such as effluent dilution, adsorption, precipitation and vegetative uptake. There is often substantial complexity in detecting and tracing effluent pathways from diffuse sources to water bodies in field studies. While source tracking as well as monitoring using tracers may assist in identifying potential pathways from STS to surface waters and estuaries, there are difficulties in scaling up from monitored individual systems to identify their contribution to the cumulative impact which may be apparent at the catchment scale. The processes which may be obvious through monitoring and dominate at the individual scale may be masked and not readily discernible at the catchment scale due to impacts from other land use activities.

  7. Criteria and methods for estimating external effective dose equivalent from personnel monitoring results: EDE implementation guide. Final report

    International Nuclear Information System (INIS)

    Owen, D.

    1998-09-01

    Title 10 Part 20 of the Code of Federal regulations requires that nuclear power plant licensees evaluate worker radiation exposure using a risk-based methodology termed the effective dose equivalent (EDE). EDE is a measure of radiation exposure that represents an individual's risk of stochastic injury from their exposure. EPRI has conducted research into how photons interact with the body. These results have been coupled with information on how the body's organs differ in their susceptibility to radiation injury, to produce a methodology for assessing the effective dose equivalent. The research and the resultant methodology have been described in numerous technical reports, scientific journal articles, and technical meetings. EPRI is working with the Nuclear Energy Institute to have the EPRI effective dose equivalent methodology accepted by the Nuclear Regulatory Commission for use at US nuclear power plants. In order to further familiarize power plant personnel with the methodology, this report summarizes the EDE research and presents some simple guidelines for its implementing the methodology

  8. Contamination Event Detection with Multivariate Time-Series Data in Agricultural Water Monitoring

    Directory of Open Access Journals (Sweden)

    Yingchi Mao

    2017-12-01

    Full Text Available Time series data of multiple water quality parameters are obtained from the water sensor networks deployed in the agricultural water supply network. The accurate and efficient detection and warning of contamination events to prevent pollution from spreading is one of the most important issues when pollution occurs. In order to comprehensively reduce the event detection deviation, a spatial–temporal-based event detection approach with multivariate time-series data for water quality monitoring (M-STED was proposed. The M-STED approach includes three parts. The first part is that M-STED adopts a Rule K algorithm to select backbone nodes as the nodes in the CDS, and forward the sensed data of multiple water parameters. The second part is to determine the state of each backbone node with back propagation neural network models and the sequential Bayesian analysis in the current timestamp. The third part is to establish a spatial model with Bayesian networks to estimate the state of the backbones in the next timestamp and trace the “outlier” node to its neighborhoods to detect a contamination event. The experimental results indicate that the average detection rate is more than 80% with M-STED and the false detection rate is lower than 9%, respectively. The M-STED approach can improve the rate of detection by about 40% and reduce the false alarm rate by about 45%, compared with the event detection with a single water parameter algorithm, S-STED. Moreover, the proposed M-STED can exhibit better performance in terms of detection delay and scalability.

  9. 2017 Update on the WFC3/UVIS Stability and Contamination Monitor

    Science.gov (United States)

    Shanahan, C. E.; Gosmeyer, C. M.; Baggett, S.

    2017-06-01

    The photometric throughput of the UVIS detector on WFC3 is monitored each cycle for its stability as a function of time, wavelength, as well as to check for any evidence of contamination on the CCD windows, which would manifest as a decrease in throughput strongest in the bluest filters. This program has been in place since the installation of WFC3 in 2009, historically making periodic observations of the spectrophotometric standard GRW+70d5824 (GRW70) in several key filters from 200 nm to 600 nm, with red filters acting as a control. This is a follow up report to the last analysis of the temporal stability of UVIS (Gosmeyer et al., 2014), since which several major changes to the program and data analysis have been implemented. Due to recent work suggesting a low-level, long-term variability for GRW70, another spectrophotometric standard star - GD153 - has been added to the program and is now analyzed in conjunction with GRW70. Data are now processed with the latest version of the CALWF3 calibration pipeline (v. 3.4), which has several new features that represent a paradigm shift in calibration methodology. Finally, the data analysis software, which was previously entirely IRAF based, was re-written in Python. We find a steady decline in the count rate for most filters but no evidence for contamination, which would manifest as a wavelength-dependent effect, impacting bluer filters more strongly. These declines range from 0.01% to 0.3% per year, and are stronger in longer wavelength filters. Similar temporal changes are found for both stars, and the long-term trends in throughput agree with previous trends derived in 2014.

  10. Progress on mobility and instability of research personnel in Japan: scientometrics on a job-posting database for monitoring the academic job market

    Energy Technology Data Exchange (ETDEWEB)

    Kawashima, H.; Yamashita, Y.

    2016-07-01

    This study has two purposes. The first purpose is to extract statistics from a database of jobposting cards, previously little-used as a data source, to assess the academic job market. The second purpose is to connect statistics on the academic job market with monitoring of indicators of policy progress related to the mobility and instability of research personnel. The data source used in this study is a job-posting database named JREC-IN Portal, which is the de facto standard for academic job seeking in Japan. The present results show a growing proportion of fixed-term researchers in the Japanese academic job market and that job information is increasingly diverse. (Author)

  11. CD-ROM nutrient analysis database assists self-monitoring behavior of active duty Air Force personnel receiving nutrition counseling for weight loss.

    Science.gov (United States)

    Heetderks-Cox, M J; Alford, B B; Bednar, C M; Heiss, C J; Tauai, L A; Edgren, K K

    2001-09-01

    This study observed the effect of using a computerized vs manual method of self-monitoring among Air Force personnel receiving nutrition counseling for weight loss. Subjects who enrolled during the first 2 weeks of the 4-week recruitment period completed food records for 6 weeks using a CD-ROM nutrient database (intervention group) whereas those who enrolled during the last 2 weeks used a food record booklet (comparison group). Of the 42 subjects (n = 23 intervention group and n = 19 comparison group), only 113 intervention and 11 comparison group subjects (57% of study enrollees) submitted at least 1 food record during the study and were included in the analysis, which included review of pre- and poststudy questionnaires, food records, and focus group data. There were no significant differences between the number of days per week documented or average number of items recorded daily. All 9 intervention as compared to 2 comparison group subjects who completed a poststudy questionnaire searched for lower-energy and lower-fat items and reported changing their dietary intake as a result. All intervention group subjects who participated in a focus group (n=6) had favorable comments about using the CD-ROM for monitoring and changing eating habits, indicating that it is a beneficial self-monitoring tool. Participants enjoyed the immediate dietary feedback, and computerized food records may be easier to interpret by nutrition counselors. A number of computerized nutrient databases are available to assist patients and consumers in managing nutritional concerns.

  12. Study and monitoring of the contamination of cultivated soils; Etude et controle de la contamination des sols cultives

    Energy Technology Data Exchange (ETDEWEB)

    Bovard, P.; Grauby, A.

    1960-07-15

    Arable lands are directly concerned by radioactive fallouts as a large part of radio-elements is fixed in the soil first centimetres in which roots of many plants are growing. The authors report the study of fixations at the level of roots, of the movements of radio-elements in the soil solution at their neighbourhood, and of the influence of leaching (by rainfalls or irrigation). Variations of soil content in calcium and strontium have been achieved to highlight dispersion and inhibition factors. The authors present the implemented experimental method, i.e. how soils have been contaminated, how crop pots have been prepared, and how the experiment is performed. Experiments are performed by using ray grass as a crop. The authors assessed radioactive uptake by aerial parts of the plant, studied the rhizosphere, and discussed radiographies obtained on different pots (contaminated, seeded or not, watered or not, with addition of different quantities of strontium or calcium compound)

  13. Monitoring priority substances, other organic contaminants and heavy metals in a volcanic aquifer from different sources and hydrological processes.

    Science.gov (United States)

    Estevez, Esmeralda; Cabrera, María del Carmen; Fernández-Vera, Juan Ramón; Molina-Díaz, Antonio; Robles-Molina, José; Palacios-Díaz, María del Pino

    2016-05-01

    Irrigation with reclaimed water (R) is necessary to guarantee the sustainability of semi-arid areas. Results obtained during a two years monitoring network (2009-2011) in Gran Canaria are presented, including the analysis of chemical parameters, N and S isotopes, priority substances (2008/105/EC, 2013/39/EU), other organic contaminants and heavy metals in groundwater and R used to irrigate a golf course. The aims of this work are to evaluate the contamination in a volcanic aquifer, relate the presence of organic contaminants and heavy metals with the hydrogeochemistry and identify pollution sources in the area. No priority substance exceeded the EU thresholds for surface water, although seventeen were detected in R. The most frequent compounds were hexachlorobenzene, chlorpyrifos ethyl, fluorene, phenanthrene and pyrene. These compounds were detected at low concentration, except chlorpyrifos. Chlorpyrifos ethyl, terbuthylazine, diuron, terbutryn, procymidone, atrazine and propazine exceeded the European threshold concentration for pesticides in groundwater (100ngL(-1)). Therefore, the priority substances chlorpyrifos ethyl and diuron must be included in monitoring studies. The priority pesticides chlorfenvinphos and diazinon were always detected in R but rarely in groundwater. Besides, the existence of contaminants not related to the current R irrigation has been identified. Absence of environmental problems related to heavy metals can be expected. The relationship among contaminant presence, hydrogeochemistry, including the stable isotopic prints of δ(18)O, δ(15)N and δ(34)S and preferential recharge paths has been described. The coastal well shows high values of EC, nitrate, a variable chemistry, and 50% of organic contaminants detected above 100ngL(-1). The well located in the recharge area presents a stable hydrochemistry, the lowest value of δ(15)N and the lowest contaminants occurrence. The area is an example of a complex volcanic media with several

  14. Exercise of laboratory comparison for contamination monitor calibration between LNMRI/IRD and LCR/UERJ - 2016

    International Nuclear Information System (INIS)

    Cabral, T.S.; David, M.

    2016-01-01

    This work was motivated by the need to decide on the best methodology to be applied in the next contamination monitor calibration comparisons with the Brazilian network of calibration radiation monitors. The calibration factor was chosen as a response calibration performed in the four monitors used in this comparison because it does not require the detector area or probe thereby reducing an important variable. It was observed that the variation of the positioning system may have an influence up to 10% in calibration. The results obtained for the calibration factor showed a difference of up to 31.2%. (author)

  15. Monitoring priority substances, other organic contaminants and heavy metals in a volcanic aquifer from different sources and hydrological processes

    International Nuclear Information System (INIS)

    Estevez, Esmeralda; Cabrera, María del Carmen; Fernández-Vera, Juan Ramón; Molina-Díaz, Antonio; Robles-Molina, José; Palacios-Díaz, María del Pino

    2016-01-01

    Irrigation with reclaimed water (R) is necessary to guarantee the sustainability of semi-arid areas. Results obtained during a two years monitoring network (2009–2011) in Gran Canaria are presented, including the analysis of chemical parameters, N and S isotopes, priority substances (2008/105/EC, 2013/39/EU), other organic contaminants and heavy metals in groundwater and R used to irrigate a golf course. The aims of this work are to evaluate the contamination in a volcanic aquifer, relate the presence of organic contaminants and heavy metals with the hydrogeochemistry and identify pollution sources in the area. No priority substance exceeded the EU thresholds for surface water, although seventeen were detected in R. The most frequent compounds were hexachlorobenzene, chlorpyrifos ethyl, fluorene, phenanthrene and pyrene. These compounds were detected at low concentration, except chlorpyrifos. Chlorpyrifos ethyl, terbuthylazine, diuron, terbutryn, procymidone, atrazine and propazine exceeded the European threshold concentration for pesticides in groundwater (100 ng L"−"1). Therefore, the priority substances chlorpyrifos ethyl and diuron must be included in monitoring studies. The priority pesticides chlorfenvinphos and diazinon were always detected in R but rarely in groundwater. Besides, the existence of contaminants not related to the current R irrigation has been identified. Absence of environmental problems related to heavy metals can be expected. The relationship among contaminant presence, hydrogeochemistry, including the stable isotopic prints of δ"1"8O, δ"1"5N and δ"3"4S and preferential recharge paths has been described. The coastal well shows high values of EC, nitrate, a variable chemistry, and 50% of organic contaminants detected above 100 ng L"−"1. The well located in the recharge area presents a stable hydrochemistry, the lowest value of δ"1"5N and the lowest contaminants occurrence. The area is an example of a complex volcanic media with

  16. Monitoring priority substances, other organic contaminants and heavy metals in a volcanic aquifer from different sources and hydrological processes

    Energy Technology Data Exchange (ETDEWEB)

    Estevez, Esmeralda, E-mail: eestevez@proyinves.ulpgc.es [Dpt. Física (GEOVOL), Universidad de Las Palmas de Gran Canaria, 35017 Las Palmas de Gran Canaria, Canary Islands (Spain); Agrifood and Phytopathological Laboratory (Cabildo de Gran Canaria), 35413 Arucas, Canary Islands (Spain); Cabrera, María del Carmen, E-mail: mcarmen.cabrera@ulpgc.es [Dpt. Física (GEOVOL), Universidad de Las Palmas de Gran Canaria, 35017 Las Palmas de Gran Canaria, Canary Islands (Spain); IMDEA Water Institute, Alcalá de Henares, Madrid (Spain); Fernández-Vera, Juan Ramón, E-mail: jrfernandezv@grancanaria.com [Agrifood and Phytopathological Laboratory (Cabildo de Gran Canaria), 35413 Arucas, Canary Islands (Spain); Molina-Díaz, Antonio, E-mail: amolina@ujaen.es [Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaen, 23071 Jaen (Spain); Robles-Molina, José, E-mail: jroblesmol@gmail.com [Analytical Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaen, 23071 Jaen (Spain); Palacios-Díaz, María del Pino, E-mail: mp.palaciosdiaz@ulpgc.es [Dpt. de Patología Animal, Producción Animal, Bromatología y Tecnología de los Alimentos (GEOVOL), Universidad de Las Palmas de Gran Canaria, 35413 Arucas, Canary Islands (Spain)

    2016-05-01

    Irrigation with reclaimed water (R) is necessary to guarantee the sustainability of semi-arid areas. Results obtained during a two years monitoring network (2009–2011) in Gran Canaria are presented, including the analysis of chemical parameters, N and S isotopes, priority substances (2008/105/EC, 2013/39/EU), other organic contaminants and heavy metals in groundwater and R used to irrigate a golf course. The aims of this work are to evaluate the contamination in a volcanic aquifer, relate the presence of organic contaminants and heavy metals with the hydrogeochemistry and identify pollution sources in the area. No priority substance exceeded the EU thresholds for surface water, although seventeen were detected in R. The most frequent compounds were hexachlorobenzene, chlorpyrifos ethyl, fluorene, phenanthrene and pyrene. These compounds were detected at low concentration, except chlorpyrifos. Chlorpyrifos ethyl, terbuthylazine, diuron, terbutryn, procymidone, atrazine and propazine exceeded the European threshold concentration for pesticides in groundwater (100 ng L{sup −1}). Therefore, the priority substances chlorpyrifos ethyl and diuron must be included in monitoring studies. The priority pesticides chlorfenvinphos and diazinon were always detected in R but rarely in groundwater. Besides, the existence of contaminants not related to the current R irrigation has been identified. Absence of environmental problems related to heavy metals can be expected. The relationship among contaminant presence, hydrogeochemistry, including the stable isotopic prints of δ{sup 18}O, δ{sup 15}N and δ{sup 34}S and preferential recharge paths has been described. The coastal well shows high values of EC, nitrate, a variable chemistry, and 50% of organic contaminants detected above 100 ng L{sup −1}. The well located in the recharge area presents a stable hydrochemistry, the lowest value of δ{sup 15}N and the lowest contaminants occurrence. The area is an example of a complex

  17. Environmental Contamination Genetic Consequences Monitoring on the Former Semipalatinsk Test Site: General Approach

    International Nuclear Information System (INIS)

    Seisebaev, A.T.; Bakhtin, M.M.; Zhapbasov, R.Zh.

    1998-01-01

    For an objective assessment of nuclear test consequences for the environment it is necessary, together with the investigation of radiation situation, to study live biological systems, particularly the genetic effects of chronic ionizing radiation. The long staying of plants and animals on the territories with the elevated radiation background level can lead to the change of organism genetic system. In this connection the monitoring of chronically exposed natural populations is of particular interest and can serve as the objective indicator of the scale of natural biota genetic damage. Basing on the results obtained during plant and animal studies one can indirectly assess the hazard of people genetic damage. Besides, studying the mutational process on natural populations exposed to the chronic ionizing radiation one can reveal new regularities, which are impossible to be detected in the laboratory conditions, and new aspects of radiation genetics. The issue of radiation adaptation of organisms affected by the various doses of ionizing radiation is very acute. The prerequisite of organism adaptation to the certain radiation background is genetic heterogeneity of individuals comprising the population and selection of radiation-induced individuals, which are the carriers of the mutation of high radioresistance. The uniqueness of the Semipalatinsk Test site and the necessity of long-term investigations of the nuclear test consequences for the environment demand the elaboration of principles for organization and utilization of natural population genetic monitoring. Radiation-genetic monitoring is the long-term observation of palpitation gene pool conditions, assessment and forecast of their spatial and time alteration, determination of limits of changes admitted under the condition of environmental radioactive contamination. It includes a series of the main research directions and has quite certain methodological peculiarities. In this paper we discuss the tasks of

  18. Some questions of optimization in the personnel dosimetry at NPP

    International Nuclear Information System (INIS)

    Liberman, A.N.; Petrov, V.I.; Bronshtejn, I.Eh.

    1978-01-01

    Some possible ways of optimizing the radiation monitoring of personnel of nuclear power plants (NPP) are considered. For premises within the zone of a strict operating regime, it is proposed that the intervals between periods of monitoring be shortened if the operating conditions are normal. To improve the monitoring of activity of water in the primary circuit, it is considered desirable to provide all NPP with a system of automatic radiation monitoring having input to the control panel. Where the work involves opening of primary circuit communications or deactivation of equipment and also in cases of emergency, it is proposed that, in addition to routine monitoring, gamma-spectrometric or radiochemical analysis of the isototip composition of contaminants be carried out. Because of the absence of measurable quantities of incorporated radionuclides in the vast majority of those working in the strict regime zone, it is suggested that the number of persons subject to systematic individual monitoring of internal radiation be limited

  19. Monitoring airborne biotic contaminants in the indoor environment of pig and poultry confinement buildings.

    Science.gov (United States)

    Hong, Pei-Ying; Li, Xiangzhen; Yang, Xufei; Shinkai, Takumi; Zhang, Yuanhui; Wang, Xinlei; Mackie, Roderick I

    2012-06-01

    Given the growing concerns over human and animal health issues related to confined animal feeding operations, an in-depth examination is required to monitor for airborne bacteria and associated antibiotic resistance genes. Our 16S rRNA-based pyrosequencing revealed that the airborne microbial community skewed towards a higher abundance of Firmicutes (> 59.2%) and Bacteroidetes (4.2-31.4%) within the confinement buildings, while the office environment was predominated by Proteobacteria (55.2%). Furthermore, bioaerosols in the confinement buildings were sporadically associated with genera of potential pathogens, and these genera were more frequently observed in the bioaerosols of pig and layer hen confinement than the turkey confinement buildings and office environment. High abundances of tetracycline resistance genes (9.55 × 10(2) to 1.69 × 10(6) copies ng(-1) DNA) were also detected in the bioaerosols sampled from confinement buildings. Bacterial lineages present in the poultry bioaerosols clustered apart from those present in the pig bioaerosols and among the different phases of pig production, suggesting that different livestock as well as production phase were associated with a distinct airborne microbial community. By understanding the diversity of biotic contaminants associated with the different confinement buildings, this study facilitates the implementation of better management strategies to minimize potential health impacts on both livestock and humans working in this environment. © 2012 Society for Applied Microbiology and Blackwell Publishing Ltd.

  20. Cuban-Brazilian comparison of the calibration procedures for surface contamination monitors

    International Nuclear Information System (INIS)

    Salas, Gonzalo W.; Garcia, Jose A.T.; Ramos, Manoel M.O.

    2007-01-01

    The calibration laboratory of the CPHR, Centro de Proteccion e Higiene de las Radiaciones, is the only laboratory that performs calibrations of radiation protection instruments in Cuba. Recently they started a cooperation project with IAEA, code number CUB3002-01 with the task title 'Assuring and Demonstrating the safety of radioactive Waste Management'. Within the frame of this project they have a compromise to implement the calibration service for surface contamination monitors, for which they received instruments and sources. In 2006 the Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI) from the Instituto de Radioprotecao e Dosimetria, IRD/CNEN, was invited to perform a mission to CPHR in order to evaluate the level of implementation of the service trough the insertion of the service in the Quality Assurance System of their laboratory, and perform a comparison exercise to test the calibration method implemented. The results were evaluated by the methodology recommended in the ISO/IEC 43-1 standard. These results show that all values from both laboratories are comparable for most radionuclides except for Cl-36. The preliminary investigation about this situation is presented in the paper. (author)

  1. Long-term electrical resistivity monitoring of recharge-induced contaminant plume behavior.

    Science.gov (United States)

    Gasperikova, Erika; Hubbard, Susan S; Watson, David B; Baker, Gregory S; Peterson, John E; Kowalsky, Michael B; Smith, Meagan; Brooks, Scott

    2012-11-01

    Geophysical measurements, and electrical resistivity tomography (ERT) data in particular, are sensitive to properties that are related (directly or indirectly) to hydrological processes. The challenge is in extracting information from geophysical data at a relevant scale that can be used to gain insight about subsurface behavior and to parameterize or validate flow and transport models. Here, we consider the use of ERT data for examining the impact of recharge on subsurface contamination at the S-3 ponds of the Oak Ridge Integrated Field Research Challenge (IFRC) site in Tennessee. A large dataset of time-lapse cross-well and surface ERT data, collected at the site over a period of 12 months, is used to study time variations in resistivity due to changes in total dissolved solids (primarily nitrate). The electrical resistivity distributions recovered from cross-well and surface ERT data agrees well, and both of these datasets can be used to interpret spatiotemporal variations in subsurface nitrate concentrations due to rainfall, although the sensitivity of the electrical resistivity response to dilution varies with nitrate concentration. Using the time-lapse surface ERT data interpreted in terms of nitrate concentrations, we find that the subsurface nitrate concentration at this site varies as a function of spatial position, episodic heavy rainstorms (versus seasonal and annual fluctuations), and antecedent rainfall history. These results suggest that the surface ERT monitoring approach is potentially useful for examining subsurface plume responses to recharge over field-relevant scales. Published by Elsevier B.V.

  2. Monitoring of Fasciola Species Contamination in Water Dropwort by cox1 Mitochondrial and ITS-2 rDNA Sequencing Analysis.

    Science.gov (United States)

    Choi, In-Wook; Kim, Hwang-Yong; Quan, Juan-Hua; Ryu, Jae-Gee; Sun, Rubing; Lee, Young-Ha

    2015-10-01

    Fascioliasis, a food-borne trematode zoonosis, is a disease primarily in cattle and sheep and occasionally in humans. Water dropwort (Oenanthe javanica), an aquatic perennial herb, is a common second intermediate host of Fasciola, and the fresh stems and leaves are widely used as a seasoning in the Korean diet. However, no information regarding Fasciola species contamination in water dropwort is available. Here, we collected 500 samples of water dropwort in 3 areas in Korea during February and March 2015, and the water dropwort contamination of Fasciola species was monitored by DNA sequencing analysis of the Fasciola hepatica and Fasciola gigantica specific mitochondrial cytochrome c oxidase subunit 1 (cox1) and nuclear ribosomal internal transcribed spacer 2 (ITS-2). Among the 500 samples assessed, the presence of F. hepatica cox1 and 1TS-2 markers were detected in 2 samples, and F. hepatica contamination was confirmed by sequencing analysis. The nucleotide sequences of cox1 PCR products from the 2 F. hepatica-contaminated samples were 96.5% identical to the F. hepatica cox1 sequences in GenBank, whereas F. gigantica cox1 sequences were 46.8% similar with the sequence detected from the cox1 positive samples. However, F. gigantica cox1 and ITS-2 markers were not detected by PCR in the 500 samples of water dropwort. Collectively, in this survey of the water dropwort contamination with Fasciola species, very low prevalence of F. hepatica contamination was detected in the samples.

  3. Radiation monitoring

    International Nuclear Information System (INIS)

    Larsson, L.Eh.; B'yuli, D.K.; Karmikel, Dzh.Kh.E.

    1985-01-01

    Recommendations on radiation monitoring of personnel, used medical ionizing radiation source, are given. The necessity to carry out radiation monitoring of situation at medical personnel's positions and personnel dosimetry is marked. It is convenient to subdivide radiation monitoring into 3 types: usual, surgical and special. Usual monitoring is connected with current work; surgical monitoring is carried out to receive information during a concrete operation; special monitoring is used to detect possible deviation from standard conditions of work or when suspecting them

  4. Combining Geoelectrical Measurements and CO2 Analyses to Monitor the Enhanced Bioremediation of Hydrocarbon-Contaminated Soils: A Field Implementation

    Directory of Open Access Journals (Sweden)

    Cécile Noel

    2016-01-01

    Full Text Available Hydrocarbon-contaminated aquifers can be successfully remediated through enhanced biodegradation. However, in situ monitoring of the treatment by piezometers is expensive and invasive and might be insufficient as the information provided is restricted to vertical profiles at discrete locations. An alternative method was tested in order to improve the robustness of the monitoring. Geophysical methods, electrical resistivity (ER and induced polarization (IP, were combined with gas analyses, CO2 concentration, and its carbon isotopic ratio, to develop a less invasive methodology for monitoring enhanced biodegradation of hydrocarbons. The field implementation of this monitoring methodology, which lasted from February 2014 until June 2015, was carried out at a BTEX-polluted site under aerobic biotreatment. Geophysical monitoring shows a more conductive and chargeable area which corresponds to the contaminated zone. In this area, high CO2 emissions have been measured with an isotopic signature demonstrating that the main source of CO2 on this site is the biodegradation of hydrocarbon fuels. Besides, the evolution of geochemical and geophysical data over a year seems to show the seasonal variation of bacterial activity. Combining geophysics with gas analyses is thus promising to provide a new methodology for in situ monitoring.

  5. Total effective dose equivalent associated with fixed uranium surface contamination

    International Nuclear Information System (INIS)

    Bogard, J.S.; Hamm, R.N.; Ashley, J.C.; Turner, J.E.; England, C.A.; Swenson, D.E.; Brown, K.S.

    1997-04-01

    This report provides the technical basis for establishing a uranium fixed-contamination action level, a fixed uranium surface contamination level exceeding the total radioactivity values of Appendix D of Title 10, Code of Federal Regulations, part 835 (10CFR835), but below which the monitoring, posting, and control requirements for Radiological Areas are not required for the area of the contamination. An area of fixed uranium contamination between 1,000 dpm/100 cm 2 and that level corresponding to an annual total effective dose equivalent (TEDE) of 100 mrem requires only routine monitoring, posting to alert personnel of the contamination, and administrative control. The more extensive requirements for monitoring, posting, and control designated by 10CFR835 for Radiological Areas do not have to be applied for these intermediate fixed-contamination levels

  6. Beta response of CaSO4:Dy based TLD badge and its angular dependence studies for personnel monitoring applications

    International Nuclear Information System (INIS)

    Kumar, Munish; Rakesh, R.B.; Sneha, C.; Ratna, P.; Bakshi, A.K.; Datta, D.

    2016-01-01

    In India, shallow/skin doses received by radiation workers from beta particles are measured using CaSO 4 :Dy based Teflon embedded TLD badge. The beta particles having maximum energy E max > 0.6 MeV - ≥ 3.54 MeV are monitored. The ratio of the response of discs under open and plastic regions (D Open/ D Perspex ) is used to estimate the energy of the beta source and to apply response correction factor. This is required as the disc dosimeters are thick and exhibit energy dependent response. Due to lack of comprehensive information regarding disc ratios and associated beta multiplication/response correction factors, present study was performed

  7. Internal contamination during enmasse coolant channel replacement (EMCCR) operation at MAPS-2, Kalpakkam

    International Nuclear Information System (INIS)

    Rajaram, S.; Sreedevi, K.R.; Rajendran, V.; Parthasarathi, S.; Kannan, V.; Gurg, R.P.

    2003-01-01

    The operation of Enmasse Coolant Channel Replacement (EMCCR) of MAPS Unit-2, started in the month of March 2002. Since the whole operation was carried out inside the reactor building in the environment of high radiation level in air, it was necessary to whole body count all the personnel involved in the operation. These personnel were whole body monitored for internal contamination due to gamma emitting radionuclides. To measure the internal contamination of the personnel a shadow shield whole body counter having NaI (Tl) detector is used. To study the concentration of airborne radionuclides present during the EMCCR job air filter samples were collected and analysed using HPGe gamma Spectrometer. It was seen that nearly 95% of the total activity present in the air was due to activation products and the remaining 5% is due to fission products. About 2000 personnel (of which 97% contract personnel) involved in the EMCCR job were whole body monitored. Around 57% showed no internal contamination. In the remaining 43% of personnel activation products such as 65 Zn, 95 Zr/ 95 Nb, and 60 Co were observed. It is interesting to note that the radionuclides observed in the internal contamination were also observed in air filter samples collected from the work spot. The observation that all the personnel involved in the EMCCR job received dose less than the Derived Recording Level (DRL) of 0.6 mSv can be attributed to a clean and neat job carried out by the management and personnel involved. (author)

  8. International systems for harmonization and quality control by in vivo monitoring and quality control by in vivo monitoring of internal contamination

    Energy Technology Data Exchange (ETDEWEB)

    Malatova, I [National Radiation Protection Inst., Prague (Czech Republic)

    1996-12-31

    After the Chernobyl accident, whole body counting for the monitoring of internal contamination of the population was widely used. In many cases, great discrepancy occurred between in vivo measured values and predicted ones from model calculations. This situation was very similar to the situation in environmental monitoring, however, by sample measurement, quality assurance and quality control of the measurement procedure is much easier than by whole body counting. In addition to it, unlike in environmental monitoring, use of semiconductor detectors by whole counting was rather limited in this time so there were few laboratories which were able to distinguish up to 20 radionuclides by which people from the vicinity of Chernobyl were internally contaminated. Therefore, effort was undertaken by many international organization to summarize current status of whole body counting and to estimate uncertainty and sensitivity of different devices. In this paper efforts to harmonize an interpretation of measured results is given. Whole body counting laboratory of the National Radiation Protection Institute (NRPI) in Prague participates in the above mentioned intercomparisons with good results and scientists from NRPI have participated in the preparation of 3 international recommendations concerning measurement of internal contamination (author).

  9. Air Monitoring Leads to Discovery of New Contamination at Radioactive Waste Disposal Site (Area G) at Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    Kraig, D.H.; Conrad, R.C.

    1999-01-01

    Air monitoring at Area G, the low-level radioactive waste disposal area at Los Alamos National Laboratory, revealed increased air concentrations of 239 Pu and 241 Am at one location along the north boundary. This air monitoring location is a couple of meters north of a dirt road used to access the easternmost part of Area G. Air concentrations of 238 Pu were essentially unaffected, which was puzzling because the 238 Pu and 239 Pu are present in the local, slightly contaminated soils. Air concentrations of these radionuclides increased about a factor of ten in early 1995 and remained at those levels until the first quarter of 1996. During the spring of 1996 air concentrations again increased by a factor of about ten. No other radionuclides were elevated and no other Area G stations showed elevations of these radionuclides. After several formal meetings didn't provide an adequate cause for the elevations, a gamma survey was performed and showed a small area of significant contamination just south of the monitor location. We found in February, 1995, a trench for a water line had been dug within a meter of so of the air stations. Then, during early 1996, the dirt road was rerouted such that its new path was directly over the unknown contamination. It appears that the trenching brought contaminated material to the surface and caused the first rise in air concentrations and then the rerouting of the road over the contamination caused the second rise, during 1996. We also found that during 1976 and 1977 contaminated soils from the clean-up of an old processing facility had been spread over the filled pits in the vicinity of the air monitors. These soils were very low in 238Pu which explains why we saw very little 238 Pu in the increased air concentrations. A layer of gravel and sand was spread over the contaminated area. Although air concentrations of 239 Pu and 241 Am dropped considerably, the y have not returned to pre-1995 levels

  10. Zero-tension lysimeters: An improved design to monitor colloid-facilitated contaminant transport in the vadose zone

    International Nuclear Information System (INIS)

    Thompson, M.L.; Scharf, R.L.; Shang, C.

    1995-01-01

    There is increasing evidence that mobile colloids facilitate the long-distance transport of contaminants. The mobility of fine particles and macromolecules has been linked to the movement of actinides, organic contaminants, and heavy metals through soil. Direct evidence for colloid mobility includes the presence of humic materials in deep aquifers as well as coatings of accumulated clay, organic matter, or sesquioxides on particle or aggregate surfaces in subsoil horizons of many soils. The potential for colloid-facilitated transport of contaminants from hazardous-waste sites requires adequate monitoring before, during, and after in-situ remediation treatments. Zero-tension lysimeters (ZTLs) are especially appropriate for sampling water as it moves through saturated soil, although some unsaturated flow events may be sampled as well. Because no ceramic barrier or fiberglass wick is involved to maintain tension on the water (as is the case with other lysimeters), particles suspended in the water as well as dissolved species may be sampled with ZTLs. In this report, a ZTL design is proposed that is more suitable for monitoring colloid-facilitated contaminant migration. The improved design consists of a cylinder made of polycarbonate or polytetrafluoroethylene (PTFE) that is placed below undisturbed soil material. In many soils, a hydraulically powered tube may be used to extract an undisturbed core of soil before placement of the lysimeter. In those cases, the design has significant advantages over conventional designs with respect to simplicity and speed of installation. Therefore, it will allow colloid-facilitated transport of contaminants to be monitored at more locations at a given site

  11. Degradation of chlorpyrifos contaminated soil by bioslurry reactor operated in sequencing batch mode: bioprocess monitoring

    International Nuclear Information System (INIS)

    Mohan, S. Venkata; Sirisha, K.; Rao, N. Chandrasekhara; Sarma, P.N.; Reddy, S. Jayarama

    2004-01-01

    Bioslurry reactor (SS-SBR) was studied for the degradation of chlorpyrifos contaminated soil using native mixed microflora, by adopting sequencing batch mode (anoxic-aerobic-anoxic) operation. Reactor operation was monitored for a total cycle period of 72 h consisting of 3 h of FILL, 64 h REACT, 2 h of SETTLE, and 3 h of DECANT with chlorpyrifos concentrations of 3000 μg/g, 6000 μg/g and 12000 μg/g. At 3000 μg/g of chlorpyrifos concentration, 91% was degraded after 72 h of the cycle period, whereas in the case of 6000 μg/g of chlorpyrifos, 82.5% was degraded. However, for 12000 μg/g of chlorpyrifos, only 14.5% degradation was observed. The degradation rate was rapid at lower substrate concentration and 12000 μg/g of substrate concentration was found to be inhibitory. Chlorpyrifos removal rate was slow during the initial phase of the sequence operation. Half-life of chlorpyrifos degradation (t 0.5 ) was estimated to be 6.3 h for 3000 μg/g of substrate, 17.5 h for 6000 μg/g and 732.2 h for 12000 μg/g. Process performance was assessed by monitoring chlorpyrifos concentration and biochemical process parameters viz., pH, oxidation and reduction potential (ORP), dissolved oxygen (DO), oxygen consumption rate (OCR) and microbial count (CFU) during sequence operation. From the experimental data obtained it can be concluded that the rate-limiting step with the bioslurry phase reactor in the process of chlorpyrifos degradation may be attributed to the concentration of substrate present in either soil or liquid phase. Periodic operations (SBR) by varying individual components of substrate with time in each process step place micro-organisms under nutritional changes from feast to famine and maintains a wide distribution in the population of micro-organisms resulting in high uptake of the substrate in the bioslurry reactor

  12. Degradation of chlorpyrifos contaminated soil by bioslurry reactor operated in sequencing batch mode: bioprocess monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Mohan, S. Venkata [Biochemical and Environmental Engineering Centre, Indian Institute of Chemical Technology, Hyderabad 500007 (India); Sirisha, K. [Electrochemical Research Laboratories, Department of Chemistry, Sri Venkateswara University, Tirupati 517502 (India); Rao, N. Chandrasekhara [Biochemical and Environmental Engineering Centre, Indian Institute of Chemical Technology, Hyderabad 500007 (India); Sarma, P.N. [Biochemical and Environmental Engineering Centre, Indian Institute of Chemical Technology, Hyderabad 500007 (India); Reddy, S. Jayarama [Electrochemical Research Laboratories, Department of Chemistry, Sri Venkateswara University, Tirupati 517502 (India)]. E-mail: profjreddy_s@yahoo.co.in

    2004-12-10

    Bioslurry reactor (SS-SBR) was studied for the degradation of chlorpyrifos contaminated soil using native mixed microflora, by adopting sequencing batch mode (anoxic-aerobic-anoxic) operation. Reactor operation was monitored for a total cycle period of 72 h consisting of 3 h of FILL, 64 h REACT, 2 h of SETTLE, and 3 h of DECANT with chlorpyrifos concentrations of 3000 {mu}g/g, 6000 {mu}g/g and 12000 {mu}g/g. At 3000 {mu}g/g of chlorpyrifos concentration, 91% was degraded after 72 h of the cycle period, whereas in the case of 6000 {mu}g/g of chlorpyrifos, 82.5% was degraded. However, for 12000 {mu}g/g of chlorpyrifos, only 14.5% degradation was observed. The degradation rate was rapid at lower substrate concentration and 12000 {mu}g/g of substrate concentration was found to be inhibitory. Chlorpyrifos removal rate was slow during the initial phase of the sequence operation. Half-life of chlorpyrifos degradation (t{sub 0.5}) was estimated to be 6.3 h for 3000 {mu}g/g of substrate, 17.5 h for 6000 {mu}g/g and 732.2 h for 12000 {mu}g/g. Process performance was assessed by monitoring chlorpyrifos concentration and biochemical process parameters viz., pH, oxidation and reduction potential (ORP), dissolved oxygen (DO), oxygen consumption rate (OCR) and microbial count (CFU) during sequence operation. From the experimental data obtained it can be concluded that the rate-limiting step with the bioslurry phase reactor in the process of chlorpyrifos degradation may be attributed to the concentration of substrate present in either soil or liquid phase. Periodic operations (SBR) by varying individual components of substrate with time in each process step place micro-organisms under nutritional changes from feast to famine and maintains a wide distribution in the population of micro-organisms resulting in high uptake of the substrate in the bioslurry reactor.

  13. EU-wide monitoring survey on emerging polar organic contaminants in wastewater treatment plant effluents.

    Science.gov (United States)

    Loos, Robert; Carvalho, Raquel; António, Diana C; Comero, Sara; Locoro, Giovanni; Tavazzi, Simona; Paracchini, Bruno; Ghiani, Michela; Lettieri, Teresa; Blaha, Ludek; Jarosova, Barbora; Voorspoels, Stefan; Servaes, Kelly; Haglund, Peter; Fick, Jerker; Lindberg, Richard H; Schwesig, David; Gawlik, Bernd M

    2013-11-01

    In the year 2010, effluents from 90 European wastewater treatment plants (WWTPs) were analyzed for 156 polar organic chemical contaminants. The analyses were complemented by effect-based monitoring approaches aiming at estrogenicity and dioxin-like toxicity analyzed by in vitro reporter gene bioassays, and yeast and diatom culture acute toxicity optical bioassays. Analyses of organic substances were performed by solid-phase extraction (SPE) or liquid-liquid extraction (LLE) followed by liquid chromatography tandem mass spectrometry (LC-MS-MS) or gas chromatography high-resolution mass spectrometry (GC-HRMS). Target microcontaminants were pharmaceuticals and personal care products (PPCPs), veterinary (antibiotic) drugs, perfluoroalkyl substances (PFASs), organophosphate ester flame retardants, pesticides (and some metabolites), industrial chemicals such as benzotriazoles (corrosion inhibitors), iodinated x-ray contrast agents, and gadolinium magnetic resonance imaging agents; in addition biological endpoints were measured. The obtained results show the presence of 125 substances (80% of the target compounds) in European wastewater effluents, in concentrations ranging from low nanograms to milligrams per liter. These results allow for an estimation to be made of a European median level for the chemicals investigated in WWTP effluents. The most relevant compounds in the effluent waters with the highest median concentration levels were the artificial sweeteners acesulfame and sucralose, benzotriazoles (corrosion inhibitors), several organophosphate ester flame retardants and plasticizers (e.g. tris(2-chloroisopropyl)phosphate; TCPP), pharmaceutical compounds such as carbamazepine, tramadol, telmisartan, venlafaxine, irbesartan, fluconazole, oxazepam, fexofenadine, diclofenac, citalopram, codeine, bisoprolol, eprosartan, the antibiotics trimethoprim, ciprofloxacine, sulfamethoxazole, and clindamycine, the insect repellent N,N'-diethyltoluamide (DEET), the pesticides

  14. Monitoring PAH contamination in water: Comparison of biological and physico-chemical tools

    International Nuclear Information System (INIS)

    Bourgeault, A.; Gourlay-Francé, C.

    2013-01-01

    The suitability of biological methods and chemical-based passive samplers to determine exposure to PAHs was tested by deploying zebra mussels and SPMDs along the Seine River over 11 months. The concentration of 13 PAHs was analyzed every month in both water and mussels. The sum of the PAH concentrations in mussels, initially at 299 ng g dry wt −1 , reached 2654, 3972 and 3727 ng g −1 at the end of exposure in the three sampling points taken through the river. The respective SPMD-available concentrations of TPAHs reached 9, 52 and 34 ng L −1 . Results showed seasonal variations of total PAH concentrations in the mussels, characterized by a decrease during spawning. The non-achievement of steady state concentration that was observed in mussels may be accounted for by the temporal variation of environmental concentrations. Thus, a bioaccumulation model based on kinetic rather than simple equilibrium partitioning was found to be more appropriate to describe PAH content in mussels. Moreover, biodynamic kinetic modeling proved useful to better understand the uptake and loss processes of pyrene. It clearly shows that these processes are markedly influenced by the biological state of the zebra mussels. The most realistic hypothesis is that the temporal variation of the biodynamic parameters may originate from a decrease of the mussels' metabolization of PAHs during spawning. Since SPMD passive samplers cannot integrate such biological factors, they are poor predictors of PAH bioavailability in mussels. - Highlights: • PAH contamination was monitored by deploying mussels and SPMDs over 11 months along the Seine River. • 5–6 ring PAHs which could not be quantified in spot samples, were measured in SPMDs. • PAH concentrations in the mussels decreased during spawning. • Temporal variation of bioaccumulated PAH may originate from a decrease of the mussels' metabolism during spawning. • Biodynamic model was allowed to explain the bioaccumulation

  15. Assessment of the Extraction Methods for Monitoring Phthalate Emerging Contaminants in Groundwater and Tap Water

    Science.gov (United States)

    Cotto, I.; Padilla, I. Y.; De Jesús, N. H.; Torres, P. M.

    2015-12-01

    Trace organic contaminants such as phthalates, among other chemicals of emerging concerns, have not historically been considered as pollutants but are being detected in water, posing a potential risk to public health and the environment. One of the most common phthalates of particular concern is di-(2-ethylhexyl) phthalate (DEHP), a plasticizer normally found in plastics and consumer products, including: cosmetics, pharmaceuticals, medical devices, food packages, water bottles, and wiring cables. DEHP has been associated with preterm birth, a major cause of neonatal mortality and health complications. This study aims at monitoring the presence and concentration of DEHP and other phthalates in groundwater and tap water systems in Puerto Rico, which has one of the highest rates of preterm birth in the U.S. The Environmental Protection Agency (EPA) suggests a liquid-liquid extraction method that uses methylene chloride as the preferred organic solvent for the extractions. This work presents modified EPA methods that reduce the volume of sample and solvent used, lower the time of analysis, increase productivity, and decrease hazards and waste. Distribution coefficient of DEHP between methylene chloride and water are estimated and related to sample extraction efficiency. Research results indicate that DEHP is in fact distributed between water and methylene chloride with a distribution coefficient average value of 1.24. The study concludes that the sample and solvent volumes have influence on the efficiency but have not an effect on the distribution coefficient. The tests show higher extraction efficiencies for lower DEHP concentrations and higher extraction volumes. Results from the water analysis show presence of DEHP in 55% of groundwater and 44% of tap water samples, indicating a potential exposure through water.

  16. Monitoring PAH contamination in water: Comparison of biological and physico-chemical tools

    Energy Technology Data Exchange (ETDEWEB)

    Bourgeault, A., E-mail: bourgeault@ensil.unilim.fr; Gourlay-Francé, C.

    2013-06-01

    The suitability of biological methods and chemical-based passive samplers to determine exposure to PAHs was tested by deploying zebra mussels and SPMDs along the Seine River over 11 months. The concentration of 13 PAHs was analyzed every month in both water and mussels. The sum of the PAH concentrations in mussels, initially at 299 ng g{sub dry} {sub wt}{sup −1}, reached 2654, 3972 and 3727 ng g{sup −1} at the end of exposure in the three sampling points taken through the river. The respective SPMD-available concentrations of TPAHs reached 9, 52 and 34 ng L{sup −1}. Results showed seasonal variations of total PAH concentrations in the mussels, characterized by a decrease during spawning. The non-achievement of steady state concentration that was observed in mussels may be accounted for by the temporal variation of environmental concentrations. Thus, a bioaccumulation model based on kinetic rather than simple equilibrium partitioning was found to be more appropriate to describe PAH content in mussels. Moreover, biodynamic kinetic modeling proved useful to better understand the uptake and loss processes of pyrene. It clearly shows that these processes are markedly influenced by the biological state of the zebra mussels. The most realistic hypothesis is that the temporal variation of the biodynamic parameters may originate from a decrease of the mussels' metabolization of PAHs during spawning. Since SPMD passive samplers cannot integrate such biological factors, they are poor predictors of PAH bioavailability in mussels. - Highlights: • PAH contamination was monitored by deploying mussels and SPMDs over 11 months along the Seine River. • 5–6 ring PAHs which could not be quantified in spot samples, were measured in SPMDs. • PAH concentrations in the mussels decreased during spawning. • Temporal variation of bioaccumulated PAH may originate from a decrease of the mussels' metabolism during spawning. • Biodynamic model was allowed to explain

  17. RADIATION HYGIENIC MONITORING AND ASSESSMENT OF POPULATION DOSES IN RADIOACTIVELY CONTAMINATED AREAS OF TULA REGION

    Directory of Open Access Journals (Sweden)

    T. M. Chichura

    2016-01-01

    Full Text Available The goal. The analyses of radiation hygienic monitoring conducted in Tula region territories affected by the Chernobyl NPP accident regarding cesium-137 and strontium- 90 in the local foodstuffs and the analyses of populational annual effective dose. The materials and methods. The survey was conducted in Tula Region since 1997 to 2015. Over that period, more than fifty thousand samples of the main foodstuffs from the post-Chernobyl contaminated area were analyzed. Simultaneously with that, the external gamma - radiation dose rate was measured in the fixed control points. The dynamics of cesium -137 and strontium-90 content in foodstuffs were assessed along with the maximum values of the mean annual effective doses to the population and the contribution of the collective dose from medical exposures into the structure of the annual effective collective dose to the population. The results. The amount of cesium-137 and strontium -90 in the local foodstuffs was identified. The external gamma- radiation dose rate values were found to be stable and not exceeding the natural fluctuations range typical for the middle latitudes of Russia’s European territory. The maximum mean annual effective dose to the population reflects the stable radiation situation and does not exceed the permissible value of 1 mSv. The contribution of the collective dose from medical exposures of the population has been continuously reducing as well as the average individual dose to the population per one medical treatment under the annual increase of the medical treatments quantities. The conclusion. There is no exceedance of the admissible levels of cesium-137 and strontium- 90 content in the local foodstuffs. The mean annual effective dose to the population has decreased which makes it possible to transfer the settlements affected by the Chernobyl NPP accident to normal life style. This is covered by the draft concept of the settlements’ transfer to normal life style.

  18. Instrument evaluation no. 11. ESI nuclear model 271 C contamination monitor

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1978-06-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to he carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the appropriate Recommendations of the International Electrotechnical Commission. The radiations in the tests are, in general, selected from the range of reference radiations for instrument calibration being drawn up by the International Standards Organisation. Normally, each report deals with the capabilities and limitations of one model of instrument and no direct comparison with other instruments intended for similar purposes is made, since the significance of particular performance characteristics largely depends on the radiations and environmental conditions in which the instrument is to be used. The results quoted here have all been obtained from tests on instruments in routine production, with the appropriate measurements being made by the NRPB. This report deals with the ESI Nuclear Model 271 C; a general purpose contamination monitor, comprising a GM tube connected by a coiled extensible cable to a ratemeter

  19. Monitoring organic contaminants in eggs of glaucous and glaucous-winged gulls (Larus hyperboreus and Larus glaucescens) from Alaska

    International Nuclear Information System (INIS)

    Vander Pol, Stacy S.; Becker, Paul R.; Ellisor, Michael B.; Moors, Amanda J.; Pugh, Rebecca S.; Roseneau, David G.

    2009-01-01

    Gull eggs have been used to monitor contaminants in many parts of the world. The Seabird Tissue Archival and Monitoring Project (STAMP) is a long-term program designed to track trends in pollutants in northern marine environments using seabird eggs. Glaucous and glaucous-winged gull (Larus hyperboreus and Larus glaucescens) eggs collected in 2005 from seven Alaskan colonies were analyzed for organic contaminants. Concentrations ranged from below detection limits to 322 ng g -1 wet mass in one egg for 4,4'-DDE and differed among the samples collected in the Gulf of Alaska and Bering and Chukchi Seas. Chick growth and survival rates may be affected by the contaminant levels found in the eggs, but the eggs should be safe for human consumption if they are eaten in small quantities. STAMP plans to continue collecting and banking gull eggs for future real-time and retrospective analyses. - Organic contaminant concentrations in Alaskan gull eggs could possibly be affecting chick growth and survival rates, but the eggs should be safe for humans to eat in small quantities

  20. Pressure monitoring and characterization of external sources of contamination at the site of the payment drinking water epidemiological studies.

    Science.gov (United States)

    Besner, Marie-Claude; Broséus, Romain; Lavoie, Jean; Giovanni, George Di; Payment, Pierre; Prévost, Michèle

    2010-01-01

    The 1990s epidemiological studies by Payment and colleagues suggested that an increase in gastrointestinal illnesses observed in the population consuming tap water from a system meeting all water quality regulations might be associated with distribution system deficiencies. In the current study, the vulnerability of this distribution system to microbial intrusion was assessed by characterizing potential sources of contamination near pipelines and monitoring the frequency and magnitude of negative pressures. Bacterial indicators of fecal contamination were recovered more frequently in the water from flooded air-valve vaults than in the soil or water from pipe trenches. The level of fecal contamination in these various sources was more similar to levels from river water rather than wastewater. Because of its configuration, this distribution system is vulnerable to negative pressures when pressure values out of the treatment plant reach or drop below 172 kPa (25 psi), which occurred nine times during a monitoring period of 17 months. The results from this investigation suggest that this distribution system is vulnerable to contamination by intrusion. Comparison of the frequency of occurrence of negative pressure events and repair rates with data from other distribution systems suggests that the system studied by Payment and colleagues is not atypical.

  1. Development of an expert system for the taking into account of uncertainties in the monitoring of internal contaminations

    International Nuclear Information System (INIS)

    Davesne, E.; Blanchardon, E.; Casanova, P.; Chojnacki, E.; Paquet, F.

    2010-01-01

    Internal contaminations may result from professional exposure and they can be monitored by anthropo-radiometric and radio-toxicological measurements which are interpreted in terms of embedded activity and effective dose by means of biokinetic and dosimetric models. In spite of standards, some uncertainties in the dosimetric interpretation of radio-toxicological measurements may remain. The authors report the development of a software (OPSCI code) which takes into account uncertainties related to the worker internal dosimetry, the calculation of the minimum detectable dose related to an exposure, and the development of a data monitoring programme

  2. Environmental contaminants in food. Volume II-part a: working papers. I. Priority setting of toxic substances for guiding monitoring programs. II. Five case studies of environmental food contamination

    International Nuclear Information System (INIS)

    1980-01-01

    This volume contains working papers written for Office of Technology Assessment (OTA) to assist in preparation of the report Environmental Contaminants in Food. The contents include: (1) Priority setting of toxic substances for guiding monitoring programs; and (2) Five case studies of environmental food contamination

  3. Use of dual-head gamma camera in radionuclide internal contamination monitoring on radiation workers from a nuclear medicine department

    International Nuclear Information System (INIS)

    Rodriguez-Laguna, A.; Brandan, M.E.

    2008-01-01

    As a part of an internal dosimetry program that is performed at the Mexican National Institute of Cancerology - Nuclear Medicine Department, in the present work we suggest a procedure for the routinely monitoring of internal contamination on radiation workers and nuclear medicine staff. The procedure is based on the identification and quantification of contaminating radionuclides in human body by using a dual-head whole-body gamma camera. The results have shown that the procedures described in this study can be used to implement a method to quantify minimal accumulated activity in the main human organs to evaluate internal contamination with radionuclides. The high sensitivity of the uncollimated gamma camera is advantageous for the routinely detection and identification of small activities of internal contamination. But, the null spatial resolution makes impossible the definition of contaminated region of interest. Then, the use of collimators is necessary to the quantification of incorporated radionuclides activities in the main human organs and for the internal doses assessment. (author)

  4. IN-SITU, LONG-TERM MONITORING SYSTEM FOR RADIOACTIVE CONTAMINANTS

    International Nuclear Information System (INIS)

    Durham, James S.; McKeever, Stephen W.S.; Akselrod, Mark S.

    2002-01-01

    This report presents the results of the first phase of the project entitled ''In-situ, Long-term Monitoring System for Radioactive Contaminants.'' Phase one of this effort included four objectives, each with specific success criteria. The first objective was to produce dosimetry grade fibers and rods of aluminum oxide. The success criterion for this milestone was the production of aluminum oxide rods and fibers that have a minimum measurable dose (MMD) of 100 mrem or less. This milestone was completed and the MMD for the rods was measured to be 1.53 mrem. Based on the MMD, the ability of the sensor to measure 137 Cs, 90 Sr/ 90 Y, and 99 Tc was evaluated. It was determined that the sensor can measure the release limit of these radionuclides (50 pCi/cm 3 ) in 150 h, 200 h, and 54,000 h, respectively. The monitor is adequate for measuring 137 Cs and 90 Sr/ 90 Y but is unsuitable for measuring 99 Tc in soil. The second objective was to construct a prototype sensor (dosimeter and fiber optic channel). There were three success criteria for this milestone: (1) Perform measurements with the sensor for both gamma and beta radiation with a standard deviation of 10% or less; (2) Demonstrate the ability of the sensor to discriminate between gamma and beta radiation; and (3) Obtain similar or relatable results for differing lengths of fiber optic cable. These milestones were met. The sensor was able to measure gamma radiation repeatedly with a standard deviation of 3.15% and beta radiation with a standard deviation of 2.85%. Data is presented that demonstrates that an end cap can be used to discriminate between beta plus gamma radiation using beta radiation from a 90 Sr/ 90 Y source, and gamma radiation alone. It is shown that some amount of attenuation occurs in longer fiber optic cables, but it is unclear if the attenuation is due to poor alignment of the dosimeter and the cable. This issue will be investigated further when more dosimeters are available so that the dosimeters

  5. IN-SITU, LONG-TERM MONITORING SYSTEM FOR RADIOACTIVE CONTAMINANTS

    International Nuclear Information System (INIS)

    Durham, James S.; McKeever, Stephen W.S.; Akselrod, Mark S.

    2002-01-01

    This report presents the results of the first phase of the project entitled ''In-situ, Long-term Monitoring System for Radioactive Contaminants.'' Phase one of this effort included four objectives, each with specific success criteria. The first objective was to produce dosimetry grade fibers and rods of aluminum oxide. The success criterion for this milestone was the production of aluminum oxide rods and fibers that have a minimum measureable dose (MMD) of 100 mrem or less. This milestone was completed and the MMD for the rods was measured to be 1.53 mrem. Based on the MMD, the ability of the sensor to measure 137 Cs, 90 Sr/ 90 Y, and 99 Tc was evaluated. It was determined that the sensor can measure the release limit of these radionuclides (50 pCi/cm 3 ) in 150 h, 200 h, and 54,000 h, respectively. The monitor is adequate for measuring 137 Cs and 90 Sr/ 90 Y but is unsuitable for measuring 99 Tc in soil. The second objective was to construct a prototype sensor (dosimeter and fiber optic channel). There were three success criteria for this milestone: (1) Perform measurements with the sensor for both gamma and beta radiation with a standard deviation of 10% or less; (2) Demonstrate the ability of the sensor to discriminate between gamma and beta radiation; and (3) Obtain similar or relatable results for differing lengths of fiber optic cable. These milestones were met. The sensor was able to measure gamma radiation repeatedly with a standard deviation of 3.15% and beta radiation with a standard deviation of 2.85%. Data is presented that demonstrates that an end cap can be used to discriminate between beta plus gamma and gamma radiation. It is shown that some amount of attenuation occurs in longer fiber optic cables, but it is unclear if the attenuation is due to poor alignment of the dosimeter and the cable. This issue will be investigated further when more dosimeters are available so that the dosimeters can be permanently attached to the longer cables. The third

  6. Unusual ratio of TL readouts of different discs of personnel monitoring TLD badge based on CaSO4: Dy teflon disc

    International Nuclear Information System (INIS)

    Pradhan, S.M.; Ande, C.D.; Kher, R.K.; Chourasiya, G.; Vashishtha, R.; Gupta, A.K.

    2005-01-01

    In India Personnel Monitoring against external radiation hazard of gamma, beta and X-rays is provided using a TLD badge based on CaSO 4 : Dy Teflon TLD disc. Unusual ratios of TL readouts of different discs of TLD badge (Disc Ratios) observed for service TLD badges of radiation workers were investigated and simulated. Simulations were carried out by exposure of TLD badges by speck type radioactive sources placed in contact of badges, exposure of TLD badges placed on concrete floor to a radiography source. Clues for the simulation were obtained from nature of work, radiological conditions during course of individuals' work whose TLD badges showed the unusual disc ratios and geometrical calculations performed. It is concluded that although the actual exposure condition during use is unknown, the unusual disk ratios observed for the service TLD badges can be simulated and utilized to arrive at probable exposure conditions. The study helped in investigations of the abnormal exposures and assigning doses to the concerned radiation workers. (author)

  7. Milk and serum standard reference materials for monitoring organic contaminants in human samples.

    Science.gov (United States)

    Schantz, Michele M; Eppe, Gauthier; Focant, Jean-François; Hamilton, Coreen; Heckert, N Alan; Heltsley, Rebecca M; Hoover, Dale; Keller, Jennifer M; Leigh, Stefan D; Patterson, Donald G; Pintar, Adam L; Sharpless, Katherine E; Sjödin, Andreas; Turner, Wayman E; Vander Pol, Stacy S; Wise, Stephen A

    2013-02-01

    Four new Standard Reference Materials (SRMs) have been developed to assist in the quality assurance of chemical contaminant measurements required for human biomonitoring studies, SRM 1953 Organic Contaminants in Non-Fortified Human Milk, SRM 1954 Organic Contaminants in Fortified Human Milk, SRM 1957 Organic Contaminants in Non-Fortified Human Serum, and SRM 1958 Organic Contaminants in Fortified Human Serum. These materials were developed as part of a collaboration between the National Institute of Standards and Technology (NIST) and the Centers for Disease Control and Prevention (CDC) with both agencies contributing data used in the certification of mass fraction values for a wide range of organic contaminants including polychlorinated biphenyl (PCB) congeners, chlorinated pesticides, polybrominated diphenyl ether (PBDE) congeners, and polychlorinated dibenzo-p-dioxin (PCDD) and dibenzofuran (PCDF) congeners. The certified mass fractions of the organic contaminants in unfortified samples, SRM 1953 and SRM 1957, ranged from 12 ng/kg to 2200 ng/kg with the exception of 4,4'-DDE in SRM 1953 at 7400 ng/kg with expanded uncertainties generally <14 %. This agreement suggests that there were no significant biases existing among the multiple methods used for analysis.

  8. Monitoring of Soil Contamination by Heavy Metals in the Impact Zone of Copper-Nickel Smelter on the Kola Peninsula

    Science.gov (United States)

    Kashulina, G. M.

    2018-04-01

    The results of landscape monitoring of the concentrations of acid-extractable Ni, Cu, Co, Mn, and Zn in soils of the local impact zone of the Severonikel industrial complex on the Kola Peninsula are discussed. The aim of monitoring studies was to reveal the spatial and temporal regularities of variation in the degree of soil contamination by heavy metals. In 2001-2011, the concentrations of acid-extractable compounds of the elements in the upper part of organic soil horizons around this plant exceeded their background concentrations by two orders of magnitude for Cu and Co and by three orders of magnitude for Ni. The degree of topsoil contamination with Ni, Cu, and Co generally corresponded to the distance of the plots from the contamination source and to the modern technogenic load. However, because of the long period of the emissions, their extreme amounts, and complex composition, indirect factors—the degree of technogenic soil degradation, the loss of soil organic matter, saturation of the surface soil layers by the contaminating metals, and competitive relationships between the elements—also affect soil contamination level. The concentrations of all the studied metals in the topsoil are characterized by considerable (1.5 to 7 times) variability in their long-term dynamics. The most important factors of this variability for Ni, Cu, and Co are the organic matter content of the samples and the amount of atmospheric precipitation in the year preceding the sampling. An inverse relationship between element concentrations in the soils and the amount of atmospheric precipitation attests to the dynamic nature and reversible character of the accumulation of heavy metals in the soils.

  9. The monitoring of radioactive contamination and radiation exposure in the environment in Germany- tasks, techniques, realizations

    International Nuclear Information System (INIS)

    Bayer, A.

    1998-01-01

    A brief historical account of the development of the monitoring of radioactivity in the environment in Germany is given. The aims of monitoring and the tasks, classified according to the possible sources of release, are presented and the methods required are described. The monitoring systems, set up on the basis of different legal principles, are presented and the technical realization of these including their current state of development, is described. Finally, an account is given of the coordination of the national monitoring systems which is at present in progress, as well as of the integration of these monitoring systems into international monitoring and information networks. (author)

  10. Monitoring of selected essential elements and contaminants at sheep and cow farms in Eastern Slovakia

    Directory of Open Access Journals (Sweden)

    Martina TUNEGOVÁ

    2016-12-01

    Full Text Available The aim of this study was to determinate the actual contamination of selected area of Slovakia, in view of its environmental character referred both to the suitability or unsuitability of the use of milk from this area, to other food processing. This article deals with analysis of the content of selected compounds in soil, feed and milk, at the cow and sheep farms. Village in Eastern Slovakia, Tulčík, was the area of investigation. This area is characterized as an area with mild disturbance of environment. 11 compounds have been analyzed (calcium, selenium, cadmium, arsenic, polychlorinated biphenyls – congeners 138, 153, 180, and pesticides - p,p´ DDE, Endosulfan I., Beta-HCH, aflatoxin M1. Samples of soil were collected once a year (spring season, samples of feeds and milk were collected two-times a year (spring and autumn season. Analysis of samples was performed in Eurofins Bel/Novamann (Nové Zámky, Slovak Republic. Analyses were performed by routine methods, according to the valid methodologies. Levels of compounds were obtained and then results have been compared with the most acceptable limits in according to applicable legislation. At both farms, 73.08% (38 samples of analyzed compounds were below the limit of quantification (LOQ and 26.92% (14 samples of compounds were quantifiable. The most significant differences between monitored farms were recorded in soil (27 720 mg·kg-1 Ca, feed (27 620 mg·kg-1 Ca and milk (960 mg·kg-1 Ca. The high content of calcium in soil and feed did not affect the content of calcium in milk. The results showed that the content of toxic elements, polychorinated biphenyls, pesticides and aflatoxin M1 in analyzed area of Eastern Slovakia was very low and under the limit of quantification. It can be concluded, that the use of milk from this area for direct use or for dairy products is appropriate and poses no health risk to the consumers.

  11. Soil Contamination, Advanced integrated characterisation and time-lapse Monitoring, SoilCAM project highlights

    Science.gov (United States)

    French, H. K.; Van Der Zee, S. E.; Wehrer, M.; Godio, A.; Pedersen, L. B.; Tsocano, G.

    2013-12-01

    The SoilCAM project (2008- 2012, EU-FP7-212663) aimed at improving methods for monitoring subsurace contaminant distribution and biodegradation. Two test sites were chosen, Oslo airport Gardermoen, Norway where de-icing agents infiltrate the soil during snowmelt and the Trecate site in Italy where an inland crude oil spill occurred in 1994. A number of geophysical investigation techniques were combined with soil and water sampling techniques. Data obtained from time-lapse measurements were further analysed by numerical modelling of flow and transport at different scales in order to characterise transport processes in the unsaturated and saturated zones. Laboratory experiments provided physical and biogeochemical data for model parameterisation and to select remediation methods. The geophysical techniques were used to map geological heterogeneities and to conduct time-lapse measurements of processes in the unsaturated zone. Both cross borehole and surface electrodes were used for electrical resistivity and induced polarisation surveys. Results showed clear indications of areas highly affected by de-icing chemicals along the runway at Oslo airport. The time lapse measurements along the runway at the airport showed infiltration patterns during snowmelt and were used to validate 2D unsaturated flow and transport simulations using SUTRA. The simulations illustrate the effect of layering geological structures and membranes, buried parallel to the runway, on the flow pattern. Complex interaction between bio-geo-chemical processes in a 1D vertical profile along the runway were described with the ORCHESTRA model. Smaller scale field site measurements revealed increase of iron and manganese during degradation of de-icing chemicals. At the Trecate site a combination of georadar, electrical resistivity and radio magneto telluric provided a broad outline of the geology down to 50 m. Anomalies in the Induced polarisation and electrical resistivity data from the cross borehole

  12. Field sampling for monitoring migration and defining the areal extent of chemical contamination

    International Nuclear Information System (INIS)

    Thomas, J.M.; Skalski, J.R.; Eberhardt, L.L.; Simmons, M.A.

    1984-11-01

    Initial research on compositing, field designs, and site mapping oriented toward detecting spills and migration at commercial low-level radioactive or chemical waste sites is summarized. Results indicate that the significance test developed to detect samples containing high levels of contamination when they are mixed with several other samples below detectable limits (composites), will be highly effective with large sample sizes when contaminant levels frequently or greatly exceed a maximum acceptable level. These conditions of frequent and high contaminant levels are most likely to occur in regions of a commercial waste site where the priors (previous knowledge) about a spill or migration are highest. Conversely, initial investigations of Bayes sampling strategies suggest that field sampling efforts should be inversely proportional to the priors (expressed as probabilities) for the occurrence of contamination

  13. Comparison of Passive Samplers for Monitoring Dissolved Organic Contaminants in Water Column Deployments

    Science.gov (United States)

    Nonionic organic contaminants (NOCs) are difficult to measure in the water column due to their inherent chemical properties resulting in low water solubility and high particle activity. Traditional sampling methods require large quantities of water to be extracted and interferen...

  14. Alpha contamination assessment for D ampersand D activities: Monitoring pipe interiors

    International Nuclear Information System (INIS)

    Rawool-Sullivan, M.W.; Conaway, J.G.; MacArthur, D.W.; Vaccarella, J.

    1996-02-01

    We have developed a prototype instrument capable of assessing alpha-emitting contamination on interior surfaces of ducts, pipes, tanks, and other enclosed volumes without inserting a probe. Air is drawn through the potentially contaminated volume and then through a detection grid, where ions created in the air by alpha particles are collected and the resulting charge measured with a sensitive electrometer. A filter at the intake end of the contaminated volume excludes externally created ions, so only ions generated inside the volume are detected. We have studied the response of this prototype in initial experiments using calibrated alpha sources with various pipe diameters and configurations, air flows, and source locations in the pipes. The results of these experiments indicate that this method can be an effective approach to assessing internal contamination

  15. Sweeping total reflection X-ray fluorescence optimisation to monitor the metallic contamination into IC manufacturing

    International Nuclear Information System (INIS)

    Borde, Yannick; Danel, Adrien; Roche, Agnes; Veillerot, Marc

    2008-01-01

    Among the methods available on the market today to control as metallic contamination in integrated circuit manufacturing, Sweeping Total reflection X-ray Fluorescence mode appears a very good method, providing fast and entire wafer mapping. With the goal of a pertinent use of Sweeping Total reflection X-ray Fluorescence in advanced Integrated Circuit manufacturing this work discusses how acceptable levels of contamination specified by the production (low levels to be detected) can be taken into account. The relation between measurement results (surface coverage, throughput, low limit of detection, limit of quantification, quantification of localized contamination) and Sweeping Total reflection X-ray Fluorescence parameters (number of measurement points and integration time per point) is presented in details. In particular, a model is proposed to explain the mismatch between actual surface contamination in a localized spot on wafer and Total reflection X-ray Fluorescence reading. Both calibration and geometric issues have been taken into account

  16. High‐resolution mass spectrometry of skin mucus for monitoring physiological impacts and contaminant biotransformation products in fathead minnows exposed to wastewater effluent

    Science.gov (United States)

    High‐resolution mass spectrometry is advantageous for monitoring physiological impacts and contaminant biotransformation products in fish exposed to complex wastewater effluent. We evaluated this technique using skin mucus from male and female fathead minnows (Pimephales pr...

  17. Performance of passive samplers for monitoring estuarine water column concentrations: 2. Emerging contaminants.

    Science.gov (United States)

    Perron, Monique M; Burgess, Robert M; Suuberg, Eric M; Cantwell, Mark G; Pennell, Kelly G

    2013-10-01

    Measuring dissolved concentrations of emerging contaminants, such as polybrominated diphenyl ethers (PBDEs) and triclosan, can be challenging due to their physicochemical properties resulting in low aqueous solubilities and association with particles. Passive sampling methods have been applied to assess dissolved concentrations in water and sediments primarily for legacy contaminants. Although the technology is applicable to some emerging contaminants, the use of passive samplers with emerging contaminants is limited. In the present study, the performance of 3 common passive samplers was evaluated for sampling PBDEs and triclosan. Passive sampling polymers included low-density polyethylene (PE) and polyoxymethylene (POM) sheets, and polydimethylsiloxane (PDMS)-coated solid-phase microextraction (SPME) fibers. Dissolved concentrations were calculated using measured sampler concentrations and laboratory-derived partition coefficients. Dissolved tri-, tetra-, and pentabrominated PBDE congeners were detected at several of the study sites at very low pg/L concentrations using PE and POM. Calculated dissolved water concentrations of triclosan ranged from 1.7 ng/L to 18 ng/L for POM and 8.8 ng/L to 13 ng/L for PE using performance reference compound equilibrium adjustments. Concentrations in SPME were not reported due to lack of detectable chemical in the PDMS polymer deployed. Although both PE and POM were found to effectively accumulate emerging contaminants from the water column, further research is needed to determine their utility as passive sampling devices for emerging contaminants. © 2013 SETAC.

  18. Monitoring system with integrated measuring sensors for radioactively contaminated iron and non-iron scrap metal (MerEN). Final report; Ueberwachungssystem mit integrierter Messsensorik fuer radioaktiv belastete Eisen- und Nichteisenschrotte (MerEN). Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Celebic, Enis; Gentes, Sascha [Karlsruher Institut fuer Technologie (KIT), Karlsruhe (Germany). Inst. fuer Technologie und Management im Baubetrieb; Rutschmann, Michael; Goerisch, Uwe [Prof. Dr.-Ing. Uwe Goerisch GmbH Ingenieurbuero fuer Abfallwirtschaft, Karlsruhe (Germany); Wetzel, Ramona [Schrott Wetzel GmbH, Mannheim (Germany)

    2015-08-15

    Radioactive sources are used in the industry, in nuclear medicine, the military, as well as in research. Accidents and losses rarely occur, a proper and responsible handling of those sources provided. Radioactive sources represent a risk when divulged, moved, passed on without authorization or lost. Time and again, radioactive sources are found at scrap yards and metal processing facilities. The supervision of these radioactive materials is gaining importance in the light of the worldwide import and export of ferrous and non-ferrous scrap. The aim of the project was to develop a space monitoring system for radioactively contaminated ferrous and non-ferrous scrap, so it can be removed from the operating range and to protect staff. The monitoring system combines technical and application-specific requirements. As part of the research project, the system was designed based on the operational framework conditions, technical and economic possibilities, and the findings from the experimental phase. The prototype mainly consists of a mainframe computer, stationary and mobile detection units, and the data transfer technology. This has successfully been tested at a scrap yard. The effects of vibrations that occur on scrapyards were investigated. This was necessary to obtain functionality of the hardware. The experimental phase was carried out based on a pre-defined set-up. The aim was to test the individual scenarios, processing and logging of the date as well to interpret the test results. In the event of radioactive sources being found in discarded metal, a standard sequence of actions was designed to protect the yard's processes and its personnel against further radioactive damage. For the first time, active radiation monitoring was performed on scrap-processing machines and in the working range of mobile devices. With this, scrap yard operators will have the opportunity to detect radioactively contaminated material at an early stage and before radiation sources are

  19. Monitoring of Radionuclide Contamination in Food Samples in Malaysia due to Daiichi Reactor Accident in Fukushima, Japan

    International Nuclear Information System (INIS)

    Nurrul Assyikeen Mohd Jaffary; Wo, Y.M.; Abdul Kadir Ishak

    2015-01-01

    On March 11, 2011, a serious accident occurred in Daiichi nuclear reactor plant, Fukushima, Japan which caused radioactive materials been released into the atmosphere in the form of aerosols and dust particles. Sea water around the plant was also found contaminated with high radioactivity readings. These radioactive materials could be transported by the winds and ocean current across international borders and cannot be controlled by human. Thus, a continuous monitoring activity of radionuclide content in the air and sea water needs to be conducted by the authorities. In addition to radioactivity monitoring, Malaysia should also control the entry of contaminated food in order to prevent radionuclide ingestion by human. The radionuclide 131 I, 134 Cs and 137 Cs were used as a measure of pollution levels and counted with gamma spectrometry using standard analysis method suggested by AOAC International. In this paper, details description of the role of Radiochemical and Environment Group, Nuclear Malaysia who is responsible in analyzing the radioactivity in the food samples due to Fukushima Daiichi, Japan accident was included. The radioactivity limit adopted and analysis results from this monitoring were discussed. (author)

  20. Response of monitors of surface contamination to internal exposition control from 131I in the 'nuclear medicine services'

    International Nuclear Information System (INIS)

    Puerta, Nancy; Rojo, Ana M.; Villella, Adrian; Gossio, Sebastian; Parada, Ines Gomez; Acosta, Norma; Arenas, German

    2013-01-01

    The IAEA, in its publication RS-G-1.2, proposes individual control of workers occupationally exposed with risk of internal exposure when the potential exposure provided by incorporation leads to a value of annual committed effective dose equal to or greater than 1 mSv. Because the radionuclide 131 I is the most important to control internal exposure in Nuclear Medicine Services, it is evaluated if the surface contamination monitors, commonly used in nuclear medicine centers of Argentina, would implement individual control of internal exposure to 131 I. Selected detectors were calibrated with a dummy neck and thyroid with calibrated sources of 131 I and 133 Ba reference. For each detector is was estimated the detection efficiency for 131 I and its detection limit. Each instrument was evaluated for the lowest effective dose possible to detect compromised by individual routine monitoring with different measurement intervals . We analyzed the response of each team for determining conditions that may be effective for the control of internal exposure of 131 I. Finally , we conclude that the daily individual monitoring surface contamination detectors available in the Nuclear Medicine Services is feasible to implement and ensures detection of significant additions of 131 I

  1. Remediating radium contaminated legacy sites: Advances made through machine learning in routine monitoring of “hot” particles

    Energy Technology Data Exchange (ETDEWEB)

    Varley, Adam, E-mail: a.l.varley@stir.ac.uk [Department of Biological and Environmental Sciences, University of Stirling, Stirling FK9 4LA (United Kingdom); Tyler, Andrew, E-mail: a.n.tyler@stir.ac.uk [Department of Biological and Environmental Sciences, University of Stirling, Stirling FK9 4LA (United Kingdom); Smith, Leslie, E-mail: l.s.smith@cs.stir.ac.uk [Department of Computing Science and Mathematics, University of Stirling, Stirling FK9 4LA (United Kingdom); Dale, Paul, E-mail: paul.dale@sepa.org.uk [Scottish Environmental Protection Agency, Radioactive Substances, Strathallan House, Castle Business Park, Stirling FK9 4TZ (United Kingdom); Davies, Mike, E-mail: Mike.Davies@nuvia.co.uk [Nuvia Limited, The Library, Eight Street, Harwell Oxford, Didcot, Oxfordshire OX11 0RL (United Kingdom)

    2015-07-15

    The extensive use of radium during the 20th century for industrial, military and pharmaceutical purposes has led to a large number of contaminated legacy sites across Europe and North America. Sites that pose a high risk to the general public can present expensive and long-term remediation projects. Often the most pragmatic remediation approach is through routine monitoring operating gamma-ray detectors to identify, in real-time, the signal from the most hazardous heterogeneous contamination (hot particles); thus facilitating their removal and safe disposal. However, current detection systems do not fully utilise all spectral information resulting in low detection rates and ultimately an increased risk to the human health. The aim of this study was to establish an optimised detector-algorithm combination. To achieve this, field data was collected using two handheld detectors (sodium iodide and lanthanum bromide) and a number of Monte Carlo simulated hot particles were randomly injected into the field data. This allowed for the detection rate of conventional deterministic (gross counts) and machine learning (neural networks and support vector machines) algorithms to be assessed. The results demonstrated that a Neural Network operated on a sodium iodide detector provided the best detection capability. Compared to deterministic approaches, this optimised detection system could detect a hot particle on average 10 cm deeper into the soil column or with half of the activity at the same depth. It was also found that noise presented by internal contamination restricted lanthanum bromide for this application. - Highlights: • Land contaminated with radium is hazardous to human health. • Routine monitoring permits identification and removal of radioactive hot particles. • Current alarm algorithms do not provide reliable hot particle detection. • Spectral processing using Machine Learning significantly improves detection.

  2. Remediating radium contaminated legacy sites: Advances made through machine learning in routine monitoring of “hot” particles

    International Nuclear Information System (INIS)

    Varley, Adam; Tyler, Andrew; Smith, Leslie; Dale, Paul; Davies, Mike

    2015-01-01

    The extensive use of radium during the 20th century for industrial, military and pharmaceutical purposes has led to a large number of contaminated legacy sites across Europe and North America. Sites that pose a high risk to the general public can present expensive and long-term remediation projects. Often the most pragmatic remediation approach is through routine monitoring operating gamma-ray detectors to identify, in real-time, the signal from the most hazardous heterogeneous contamination (hot particles); thus facilitating their removal and safe disposal. However, current detection systems do not fully utilise all spectral information resulting in low detection rates and ultimately an increased risk to the human health. The aim of this study was to establish an optimised detector-algorithm combination. To achieve this, field data was collected using two handheld detectors (sodium iodide and lanthanum bromide) and a number of Monte Carlo simulated hot particles were randomly injected into the field data. This allowed for the detection rate of conventional deterministic (gross counts) and machine learning (neural networks and support vector machines) algorithms to be assessed. The results demonstrated that a Neural Network operated on a sodium iodide detector provided the best detection capability. Compared to deterministic approaches, this optimised detection system could detect a hot particle on average 10 cm deeper into the soil column or with half of the activity at the same depth. It was also found that noise presented by internal contamination restricted lanthanum bromide for this application. - Highlights: • Land contaminated with radium is hazardous to human health. • Routine monitoring permits identification and removal of radioactive hot particles. • Current alarm algorithms do not provide reliable hot particle detection. • Spectral processing using Machine Learning significantly improves detection

  3. Early-stage bioassay for monitoring radioactive contamination in living livestock.

    Science.gov (United States)

    Yamaguchi, Toshiro; Sawano, Kaita; Kishimoto, Miori; Furuhama, Kazuhisa; Yamada, Kazutaka

    2012-12-01

    Soil samples from the ground surface and feces and blood from a mixed-breed male pig were collected on April 10, 2011 at a farm within 20 km of the Fukushima Daiichi nuclear power plant. The radioactivity of each sample was measured using a Ge semiconductor detector. Despite the fact that the pig had been fed non-contaminated imported feed, (131)I, (134)Cs and (137)Cs were detected in the feces, and (134)Cs and (137)Cs were detected in the blood clots. Because it is considerably difficult to measure radioactive contamination in the edible muscle of living livestock, bioassays are an option for the screening of radioactive contamination in living livestock to ensure food safety.

  4. In-situ protein determination to monitor contamination in a centrifugal partition chromatograph.

    Science.gov (United States)

    Bouiche, Feriel; Faure, Karine

    2017-05-15

    Centrifugal partition chromatography (CPC) works with biphasic liquid systems including aqueous two-phase systems. Metallic rotors are able to retain an aqueous stationary phase able to purify proteins. But the adhesion of proteins to solid surface may pose a cross-contamination risk during downstream processes. So it is of utmost importance to ensure the cleanliness of the equipment and detect possible protein contamination in a timely manner. Thereby, a direct method that allows the determination of the effective presence of proteins and the extent of contamination in the metallic CPC rotors was developed. This in-situ method is derived from the Amino Density Estimation by Colorimetric Assay (ADECA) which is based on the affinity of a dye, Coomassie Brillant Blue (CBB), with protonated N + groups of the proteins. In this paper, the ADECA method was developed dynamically, on a 25 mL stainless-steel rotor with various extents of protein contaminations using bovine serum albumin (BSA) as a fouling model. The eluted CBB dye was quantified and found to respond linearly to BSA contamination up to 70 mg injected. Limits of detection and quantification were recorded as 0.9 mg and 3.1 mg, respectively. While the non-specific interactions between the dye and the rotor cannot currently be neglected, this method allows for in situ determination of proteins contamination and should contribute to the development of CPC as a separation tool in protein purification processes. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Radiometric monitoring of contaminated scrap metals imported in Italy. Technical and regulatory features

    International Nuclear Information System (INIS)

    Dobici, F.; Piermattei, S.; Susanna, A.

    1996-01-01

    During these last ten years there have been occasional reports of mishaps from trafficking of contaminated scraps or containing radioactive sources. Recently an increase of events indicated that the problem becomes more important as to generate possible consequences, from a radiation protection standpoint, for workers and general public. Following the detection of contaminated metal scraps in some recycling industries and in some consignments entering the Italian borders, the competent Authorities laid down rules to put the matter under control. In this paper technical and regulatory features are discussed. (author)

  6. Air Monitoring to Control the Intake of Airborne Radioiodine-131 Contaminants by Nuclear Medicine Workers

    International Nuclear Information System (INIS)

    Jiemwutthisak, P.; Sritongkul, N.; Chaudakshetrin, P.; Kanchanaphiboon, P.; Tuntawiroon, M.

    2012-01-01

    Inhalation of radioiodine-131 is the largest cause of internal dose to nuclear medicine workers. The concentration of radioiodine-131 in air is limited by the Derived Air Concentration (DAC) of 416.67 Bq/m3. In this study air monitoring shall be performed to measure the radioiodine-131 contaminant in air by sample collection and analysis. Air samples were drawn from areas where there is a potential for I-131 airborne radioactivity e.g. in the hot laboratory, radioiodine treatment rooms, radioactive waste collection areas and waste water treatment plant. A portable battery-operated air sampler, Gilian BDX II with carbon- impregnated cellulose filters was used for air sampling. The flow rate was adjusted to 3 liters per minute and the sampler run for 180 minutes. Iodine-131 radioactivity on filter was measured for 10 minutes by 2 NaI(Tl) gamma counters, Perkin Elmer Wallac Wizard 1480 (3''x3'') and Atomlab 950 PC (2''x2'') with and objective for inter comparison. Counting efficiency of the counters are 57 and 39 percent respectively. Agreeable results of I-131 radioactivity were obtained from both gamma counters. The mean I-131 concentrations measured by Wallac(Atomlab) were 31.59±16.31 (29.84±14.74) Bq/m 3 in radioiodine fume hood for treatment dose dispensing, 8.98±4.33 (7.58±5.10) Bq/m 3 in fume hood accommodated with a dose calibrator, 7.80±5.39 (7.54±5.04) Bq/m 3 in radioactive waste storage area, 0.03±0.54 (0.03±0.57) Bq/m 3 in patient waiting area, 2.94±3.60 (2.55±2.98) Bq/m 3 in hospital ward waste collection area and 0.03±0.01 (0.03±0.01) Bq/m 3 in the water treatment plant area. Radioiodine concentrations in patient's room increases linearly as the administered dose was increasing. Mean±SD of the measured concentrations were 11.63±9.30 (9.86±8.98) Bq/m 3 , 18.57±13.24 (17.35±12.33) Bq/m 3 and 31.90±22.32 (30.90±22.49) Bq/m 3 for the administered doses of 3.7, 5.55 and 7.4 Bq respectively. Radioiodine concentrations in all specified areas

  7. Roshydromet system of environment radioactive contamination monitoring in the Arctic region of Russia

    International Nuclear Information System (INIS)

    Chelukanov, V.

    1995-01-01

    159 arctic hydrometerological stations take measurements of gamma radiation. 51 stations monitor the density of atmospheric radioactive fallout and 12 stations monitor the concentration of aerosols. 13 hydrological stations sited in the mouths of main Arctic Ocean rivers take water samples. Regional laboratories carry out isotop analysis of samples. Information on high levels of a radioactivity measured at the monitoring stations, as well as information on abnormal radioactivity from regional laboratories are transmitted to the Information Centers on the monitoring system (Moscow and Obnisk) by cable. 2 figs., 1 tab

  8. New ICPP portal monitor

    International Nuclear Information System (INIS)

    Georgeson, M.A.; Nichols, C.E.

    1981-04-01

    A large area gas filled proportional-detector portal monitor mounted in a swinging door frame has been designed and developed at the Idaho Chemical Processing Plant (ICPP). This monitor extends the sensitivity and speed of personnel contamination detection to levels equal to or exceeding that obtained using hand-held portable survey techniques. The new monitor has state-of-the-art electronics which result in rapid response, and use statistical principles in the alarm logic to reduce or eliminate spurious alarms. In addition, the evaluation of this instrument indicates that it will detect small enough quantities of U-235 in shielded containers to meet current special nuclear materials (SNM) detection standards. Simultaneous detection of very low level contamination and small quantities of SNM results in a monitor particularly useful for nuclear installations

  9. Ecotoxicity monitoring of hydrocarbon-contaminated soil during bioremediation: a case study

    Czech Academy of Sciences Publication Activity Database

    Hubálek, Tomáš; Vosáhlová, S.; Matějů, V.; Kováčová, Nora; Novotný, Čeněk

    2007-01-01

    Roč. 52, č. 1 (2007), s. 1-7 ISSN 0090-4341 R&D Projects: GA MŠk LN00B030; GA AV ČR KJB600200514 Institutional research plan: CEZ:AV0Z50200510 Keywords : bioremediation * ecotoxicity * hydrocarbon-contaminated soil Subject RIV: EE - Microbiology, Virology Impact factor: 1.620, year: 2007

  10. Development of a multistrain bacterial bioreporter platform for the monitoring of hydrocarbon contaminants in marine environments

    NARCIS (Netherlands)

    Tecon, R.; Beggah, S.; Czechowska, K.; Sentchilo, V.; Chronopoulou, P.M.; McGenity, T.J.; van der Meer, J.R.

    2010-01-01

    Petroleum hydrocarbons are common contaminants in marine and freshwater aquatic habitats, often occurring as a result of oil spillage. Rapid and reliable on-site tools for measuring the bioavailable hydrocarbon fractions, i.e., those that are most likely to cause toxic effects or are available for

  11. Exposure assessment of process-related contaminants in food by biomarker monitoring

    NARCIS (Netherlands)

    Rietjens, Ivonne M.C.M.; Dussort, P.; Günther, Helmut; Hanlon, Paul; Honda, Hiroshi; Mally, Angela; O’Hagan, Sue; Scholz, Gabriele; Seidel, Albrecht; Swenberg, James; Teeguarden, Justin; Eisenbrand, Gerhard

    2018-01-01

    Exposure assessment is a fundamental part of the risk assessment paradigm, but can often present a number of challenges and uncertainties. This is especially the case for process contaminants formed during the processing, e.g. heating of food, since they are in part highly reactive and/or volatile,

  12. Evaluation of a hygiene monitor for detection of contamination in dental surgeries.

    Science.gov (United States)

    Douglas, C W; Rothwell, P S

    1991-05-11

    Routines for disinfecting working surfaces in dental surgeries are difficult to monitor without time-consuming and labour-intensive microbiological techniques, yet effective monitoring is a vital part of cross-infection control. Easy to use, on-site methods would be valuable in this context. This study evaluates a portable monitor, the Biotrace Hygiene Monitor, which uses bioluminescence to measure adenosine triphosphate (ATP) on surfaces. Under laboratory conditions, the ability of the monitor to detect whole saliva and Streptococcus sanguis was determined and, in the general practice environment, the level of ATP on surfaces in five dental surgeries was assessed. The minimum amount of saliva detectable was 0.5 microliters and in surgeries, the monitor readily identified numerous surfaces with fairly high levels of ATP. Routine cleaning methods sometimes left ATP on surfaces at levels which represented a cross-infection risk, if it is assumed that the ATP derived from patients' saliva. Modification of cleaning methods resulted in a reduction of ATP levels to within that which could be considered reasonably practicably safe. It is concluded that the Biotrace Hygiene Monitor offers a simple and valuable means of monitoring dental practice cleaning routines.

  13. Evaluating Monitoring Strategies to Detect Precipitation-Induced Microbial Contamination Events in Karstic Springs Used for Drinking Water

    Directory of Open Access Journals (Sweden)

    Michael D. Besmer

    2017-11-01

    Full Text Available Monitoring of microbial drinking water quality is a key component for ensuring safety and understanding risk, but conventional monitoring strategies are typically based on low sampling frequencies (e.g., quarterly or monthly. This is of concern because many drinking water sources, such as karstic springs are often subject to changes in bacterial concentrations on much shorter time scales (e.g., hours to days, for example after precipitation events. Microbial contamination events are crucial from a risk assessment perspective and should therefore be targeted by monitoring strategies to establish both the frequency of their occurrence and the magnitude of bacterial peak concentrations. In this study we used monitoring data from two specific karstic springs. We assessed the performance of conventional monitoring based on historical records and tested a number of alternative strategies based on a high-resolution data set of bacterial concentrations in spring water collected with online flow cytometry (FCM. We quantified the effect of increasing sampling frequency and found that for the specific case studied, at least bi-weekly sampling would be needed to detect precipitation events with a probability of >90%. We then proposed an optimized monitoring strategy with three targeted samples per event, triggered by precipitation measurements. This approach is more effective and efficient than simply increasing overall sampling frequency. It would enable the water utility to (1 analyze any relevant event and (2 limit median underestimation of peak concentrations to approximately 10%. We conclude with a generalized perspective on sampling optimization and argue that the assessment of short-term dynamics causing microbial peak loads initially requires increased sampling/analysis efforts, but can be optimized subsequently to account for limited resources. This offers water utilities and public health authorities systematic ways to evaluate and optimize their

  14. Evidence for Legacy Contamination of Nitrate in Groundwater of North Carolina Using Monitoring and Private Well Data Models

    Science.gov (United States)

    Messier, K. P.; Kane, E.; Bolich, R.; Serre, M. L.

    2014-12-01

    Nitrate (NO3-) is a widespread contaminant of groundwater and surface water across the United States that has deleterious effects to human and ecological health. Legacy contamination, or past releases of NO3-, is thought to be impacting current groundwater and surface water of North Carolina. This study develops a model for predicting point-level groundwater NO3- at a state scale for monitoring wells and private wells of North Carolina. A land use regression (LUR) model selection procedure known as constrained forward nonlinear regression and hyperparameter optimization (CFN-RHO) is developed for determining nonlinear model explanatory variables when they are known to be correlated. Bayesian Maximum Entropy (BME) is then used to integrate the LUR model to create a LUR-BME model of spatial/temporal varying groundwater NO3- concentrations. LUR-BME results in a leave-one-out cross-validation r2 of 0.74 and 0.33 for monitoring and private wells, effectively predicting within spatial covariance ranges. The major finding regarding legacy sources NO3- in this study is that the LUR-BME models show the geographical extent of low-level contamination of deeper drinking-water aquifers is beyond that of the shallower monitoring well. Groundwater NO3- in monitoring wells is highly variable with many areas predicted above the current Environmental Protection Agency standard of 10 mg/L. Contrarily, the private well results depict widespread, low-level NO3-concentrations. This evidence supports that in addition to downward transport, there is also a significant outward transport of groundwater NO3- in the drinking water aquifer to areas outside the range of sources. Results indicate that the deeper aquifers are potentially acting as a reservoir that is not only deeper, but also covers a larger geographical area, than the reservoir formed by the shallow aquifers. Results are of interest to agencies that regulate surface water and drinking water sources impacted by the effects of

  15. Monitoring of Environmental Contamination and Addressing Health Risks Through the Analysis of Teeth by Means of Nuclear Techniques

    International Nuclear Information System (INIS)

    Oliveira, M.C.C.; Arruda-Neto, J.D.T.; Deppman, A.; Likhachev, V.P.; Medero, D.R.; Luzardo, F.M.; Cazorla, L.L.; Dias, J.F.; Yoneama, M.L.

    2003-01-01

    Radionuclides (mostly uranium and thorium) and heavy metals (lead and cadmium) are environmental contaminants produced by agricultural and industrial activities, or are simply the result of soil and water pollution by non regular human activities (e.g. disposal of garbage in rivers and water ponds). Humans incorporate these contaminants via the food chain, where bones are the most important target-organ. The incidence of health risk and hazards would depend, obviously, on the time length and intensity of such incorporation. However, while in vivo monitoring of human bones is difficult, the analysis of teeth is a promising possibility, particularly for the quantification of lead and cadmium in deciduous tooth (milk tooth), and uranium in adult tooth. This study will be focused, initially, on the Guarapiranga dam and on the human settlements located in its surroundings. Their teeth will be collected and classified by age and social-economical status, with the collaboration of the Dentistry School from UNISA, which is developing several social tasks in the Guarapiranga region. Water, plants and fishes will be collected and analyzed too, aiming at biokinetic al study of contaminants, particularly the transfer dynamics among the species of the dam. (Author)

  16. Gulf of Mexico offshore operations monitoring experiment (GOOMEX), phase I : sublethal responses to contaminant exposure - introduction and overview

    International Nuclear Information System (INIS)

    Kennicutt, M.C.; Green, R.H.; Montagna, P.

    1996-01-01

    The Gulf of Mexico Offshore Operations Monitoring Experiment (GOOMEX) is a three-phase study to test and evaluate a range of biological, biochemical, and chemical methodologies to detect and assess chronic sublethal biological impacts in the vicinity of long-duration activities associated with oil and gas exploration and production. A chronic impact is defined as an effect on the biota caused by exposure to the long-term accumulation of chemicals in the environment. The basic program, comprising four field activities over a 2-yr period, was designed to detect nearfield impacts and contaminant gradients extending out from each site. Five test sites were evaluated and three selected as most appropriate for long-term study: MU-A85, MAI-686, and HI-A389. The sampling design included a radial pattern with stations at 30-50, 100, 200, 500, and 3000 m distance and employed a dose-response model to test the hypotheses that biological, chemical, and biochemical variations are due to platform-derived contaminants. Study components included contaminant (trace metals and hydrocarbons) analysis in sediments, pore waters, and biological tissues; assemblage analysis of benthic meiofauna, infauna, and epifauna, assessment of community health based on life history and reproduction studies; and the induction of detoxification responses. (author). 57 refs., 9 tabs., 5 figs

  17. Self-potential monitoring of a crude oil contaminated site (Trecate, Italy): first results of the modelling.

    Science.gov (United States)

    Giampaolo, V.; Rizzo, E.; Titov, K.; Maineult, A.; Lapenna, V.

    2012-04-01

    The contamination of soils and groundwater by hydrocarbon, due to blow out, leakage from tank or pipe and oil spill, is a heavy environmental problem because infiltrated oil can persist in the ground for a long time. The existing methods used for the remediation of these contaminated sites are invasive, time consuming and expensive. Therefore, in the last years, there was a growing interest in the use of geophysical methods for environmental monitoring (Atekwana et al., 2000; Chambers et al., 2004; Song et al., 2005; French et al., 2009). A particular attention is given to the self-potential (SP) method because SP is sensitive to the contaminant chemistry and redox processes generated by bacteria during the biodegradation (Atekwana et al., 2004; Naudet and Revil, 2005; Revil et al., 2010). Here we show the results of SP investigations carried out at Trecate site (Italy). This site was affected by a crude oil contamination from a well blowout in 1994. Four SP surveys (October 2009, March 2010, October 2010, and March 2011) were conducted at the site, both in the contaminated and uncontaminated regions. Significant changes are observed between SP data collected at different times. In particular, we found mostly negative electrical potential in October surveys and positive electrical potential in March surveys. The SP distributions can be interpreted as the superposition of many components, including a horizontal water-flow in the saturated shallow aquifer toward South-East, the infiltration movement of water in the unsaturated zone and, possibly, the oxidation-reduction phenomena due to bacterial activity. As the groundwater flow usually produces SP linear trends, the data were detrended by linear regression, taking into account the measured piezometric heads in the aquifer. The detrended SP data show that the SP distribution within the contaminated zone is generally bipolar in October: the southern part of the contaminated area is characterized by negative values

  18. Monitoring of beach contamination following an incident at BNFL, Sellafield, Cumbria in November 1983

    International Nuclear Information System (INIS)

    1985-01-01

    This report jointly produced by RCI/DOE and MAFF presents for the period from November 1983 to July 1984: 1) the monitoring programmes and techniques used by BNFL, DOE and MAFF; 2) the results of the monitoring programmes; 3) actions taken as a consequence of the monitoring results; 4) an outline of the position at the end of July 1984 when the Secretary of State for Environment announced, after consultation with MAFF, the DHSS and NRPB, withdrawal of advice to avoid unnecessary use of the beaches. (UK)

  19. Monitoring of Radionuclide Contamination in Food Samples in Malaysia due to Daiichi Reactor Accident in Fukushima, Japan

    International Nuclear Information System (INIS)

    Nurrul Assyikeen Mohd Jaffary; Abdul Kadir Ishak; Wo, Y.M.

    2011-01-01

    On March 11, 2011, a serious accident occurred in Daiichi nuclear reactor plant, Fukushima, Japan which caused radioactive materials been released into the atmosphere in the form of aerosols and dust particles. Sea water around the plant was also found contaminated with high radioactivity readings. These radioactive materials could be transported by the winds and ocean current across international borders and cannot be controlled by human. Besides a continuous monitoring activity of radionuclide content in the air and sea water that need to be conducted by the authorities, Malaysia should also control the entry of radionuclide through contaminated food ingestion by human. Radionuclide I-131, Cs-134 and Cs-137 were used as a counter-measure of pollution levels and counted with gamma spectrometry using standard analysis method suggested by AOAC International. In this paper, details description of the role of Radiochemical and Environment Group, Nuclear Malaysia who's responsible in analyzing the radioactivity in the food samples due to Fukushima Daiichi, Japan accident was included. Also discussed are the radioactivity limit adopted and analysis results from this monitoring. (author)

  20. New miniaturized alpha/beta spectrometric system for the surface contamination monitoring and radon personal dosimeter

    International Nuclear Information System (INIS)

    Streil, T.; Oeser, V.; Holfeld, G.

    1998-01-01

    The heart of the new miniaturized alpha/beta spectroscopic system is a Smart Card MCA having a 12 bit resolution and a 32 bit memory for each channel with the size of a cheque card. The system consists of a single or up to 12 alpha spectrometers in a battery powered casing with connectors for direct detector/amplifier module plugging. Surface contamination in the order of 1 Bq/cm 2 of 239 Pu can be measured. (M.D.)

  1. Preconcentration for Improved Long-term Monitoring of Contaminants in Groundwater

    Science.gov (United States)

    2014-04-10

    facilities where waste from weapons manufacture, storage, and reclamation processes has leached into the soil and groundwater. Key contaminants...and current testing and training facilities where waste from weapons manufacture, storage, and reclamation processes has leached into the soil and...scale, bread -board level, prototype was assembled using a peristaltic pump with a 900:1 motor and 0.143” rollers (P625/900.143, Instech Laboratories

  2. Unmanned aerial vehicles for the assessment and monitoring of environmental contamination: An example from coal ash spills.

    Science.gov (United States)

    Messinger, Max; Silman, Miles

    2016-11-01

    Unmanned aerial vehicles (UAVs) offer new opportunities to monitor pollution and provide valuable information to support remediation. Their low-cost, ease of use, and rapid deployment capability make them ideal for environmental emergency response. Here we present a UAV-based study of the third largest coal ash spill in the United States. Coal ash from coal combustion is a toxic industrial waste material present worldwide. Typically stored in settling ponds in close proximity to waterways, coal ash poses significant risk to the environment and drinking water supplies from both chronic contamination of surface and ground water and catastrophic pond failure. We sought to provide an independent estimate of the volume of coal ash and contaminated water lost during the rupture of the primary coal ash pond at the Dan River Steam Station in Eden, NC, USA and to demonstrate the feasibility of using UAVs to rapidly respond to and measure the volume of spills from ponds or containers that are open to the air. Using structure-from-motion (SfM) imagery analysis techniques, we reconstructed the 3D structure of the pond bottom after the spill, used historical imagery to estimate the pre-spill waterline, and calculated the volume of material lost. We estimated a loss of 66,245 ± 5678 m 3 of ash and contaminated water. The technique used here allows rapid response to environmental emergencies and quantification of their impacts at low cost, and these capabilities will make UAVs a central tool in environmental planning, monitoring, and disaster response. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Aflatoxin B1 contamination in feed from Puglia and Basilicata regions (Italy): 5 years monitoring data.

    Science.gov (United States)

    Vita, V; Clausi, M T; Franchino, C; De Pace, R

    2016-11-01

    During a 5-year period from 2010 to 2014, n = 919 samples of feed and raw materials were analyzed for aflatoxin B 1 (AFB 1 ) contamination using accredited ELISA screening methods. Only 0.76 % of these samples were non-compliant with maximum levels set by the European Union Regulation 32/2002. Non-compliant samples were mainly from the province of Bari (n = 3 samples, mean AFB 1 value 7.03 μg/kg), although the highest AFB 1 levels were found in two samples from the provinces of Foggia and Brindisi, at 32.6 ± 3.6 μg/kg and 31.0 ± 4.0 μg/kg, respectively. Mean AFB 1 levels in samples contaminated but compliant with the limits ranged from 1.4 to 2.2 μg/kg. Considering the great importance of climate conditions in mycotoxins production, during crops production and during the critical phases of materials storage and/or transport, to better understand the variability in contamination levels, the analytical results were reviewed in term of temperature and relative environmental humidity in the sampling areas. Correlations between aflatoxin B 1 levels in feed and these climate factors might explain seasonal and annual variations in contamination levels. The data from the present study provide useful suggestions for the organization of targeted monitoring plans and the protection of consumers, as well as for improvement in the quality standards of zootechnological activities and feed industry.

  4. Vadose zone studies at an industrial contaminated site: the vadose zone monitoring system and cross-hole geophysics

    Science.gov (United States)

    Fernandez de Vera, Natalia; Beaujean, Jean; Jamin, Pierre; Nguyen, Frédéric; Dahan, Ofer; Vanclooster, Marnik; Brouyère, Serge

    2014-05-01

    In order to improve risk characterization and remediation measures for soil and groundwater contamination, there is a need to improve in situ vadose zone characterization. However, most available technologies have been developed in the context of agricultural soils. Such methodologies are not applicable at industrial sites, where soils and contamination differ in origin and composition. In addition, most technologies are applicable only in the first meters of soils, leaving deeper vadose zones with lack of information, in particular on field scale heterogeneity. In order to overcome such difficulties, a vadose zone experiment has been setup at a former industrial site in Belgium. Industrial activities carried out on site left a legacy of soil and groundwater contamination in BTEX, PAH, cyanide and heavy metals. The experiment comprises the combination of two techniques: the Vadose Zone Monitoring System (VMS) and cross-hole geophysics. The VMS allows continuous measurements of water content and temperature at different depths of the vadose zone. In addition, it provides the possibility of pore water sampling at different depths. The system is formed by a flexible sleeve containing monitoring units along its depth which is installed in a slanted borehole. The flexible sleeve contains three types of monitoring units in the vadose zone: Time Domain Transmissometry (TDT), which allows water content measurements; Vadose Sampling Ports (VSP), used for collecting water samples coming from the matrix; the Fracture Samplers (FS), which are used for retrieving water samples from the fractures. Cross-hole geophysics techniques consist in the injection of an electrical current using electrodes installed in vertical boreholes. From measured potential differences, detailed spatial patterns about electrical properties of the subsurface can be inferred. Such spatial patterns are related with subsurface heterogeneities, water content and solute concentrations. Two VMS were

  5. LRAD surface monitoring results at TA-21

    International Nuclear Information System (INIS)

    Bounds, J.A.

    1995-01-01

    In August/September 1994, NIS-6 personnel used LRAD soil surface monitor technology to characterize the extent of alpha contamination on the surface of a parking lot adjacent to TA-21, LANL, known as Material Disposal Area B. This report documents that monitoring. Based on this survey, there is no reason for concern about significant contamination in the parking area as a whole, although unexpected small hot spots could exist between the grid points where monitoring was performed. However, the grouping of high readings on the east side of the parking area does point to possible contamination at the level of 100 dpm/100 cm 2 or less (above background). Further monitoring or remediation of this area seems appropriate. In addition, because this was an alpha survey, one cannot rule out contamination under the asphalt or possibly between layers if it was paved more than once

  6. A low cost mid-infrared sensor for on line contamination monitoring of lubricating oils in marine engines

    Science.gov (United States)

    Ben Mohammadi, L.; Kullmann, F.; Holzki, M.; Sigloch, S.; Klotzbuecher, T.; Spiesen, J.; Tommingas, T.; Weismann, P.; Kimber, G.

    2010-04-01

    The chemical and physical condition of oils in marine engines must be monitored to ensure optimum performance of the engine and to avoid damage by degraded oil not adequately lubricating the engine. Routine monitoring requires expensive laboratory testing and highly skilled analysts. This work describes the adaptation and implementation of a mid infrared (MIR) sensor module for continued oil condition monitoring in two-stroke and four-stroke diesel engines. The developed sensor module will help to reduce costs in oil analysis by eliminating the need to collect and send samples to a laboratory for analysis. The online MIR-Sensor module measures the contamination of oil with water, soot, as well as the degradation indicated by the TBN (Total Base Number) value. For the analysis of water, TBN, and soot in marine engine oils, four spectral regions of interest have been identified. The optical absorption in these bands correlating with the contaminations is measured simultaneously by using a four-field thermopile detector, combined with appropriate bandpass filters. Recording of the MIR-absorption was performed in a transmission mode using a flow-through cell with appropriate path length. Since in this case no spectrometer is required, the sensor including the light source, the flowthrough- cell, and the detector can be realised at low cost and in a very compact manner. The optical configuration of the sensor with minimal component number and signal intensity optimisation at the four-field detector was implemented by using non-sequential ray tracing simulation. The used calibration model was robust enough to predict accurately the value for soot, water, and TBN concentration for two-stroke and four-stroke engine oils. The sensor device is designed for direct installation on the host engine or machine and, therefore, becoming an integral part of the lubrication system. It can also be used as a portable stand-alone system for machine fluid analysis in the field.

  7. Radiation protection - Monitoring of workers occupationally exposed to a risk of internal contamination with radioactive material

    International Nuclear Information System (INIS)

    2006-01-01

    In the course of employment, individuals might work with radioactive materials that, under certain circumstances, could be taken into the body. Protecting workers against risks of incorporated radionuclides requires the monitoring of potential intakes and/or the quantification of actual intakes and exposures. The selection of measures and programmes for this purpose requires decisions concerning methods, techniques, frequencies etc. for measurements and dose assessment. The criteria permitting the evaluation of the necessity of such a monitoring programme or for the selection of methods and frequencies of monitoring usually depend upon the legislation, the purpose of the radiation protection programme, the probabilities of potential radionuclide intakes, and the characteristics of the materials handled. This International Standard offers guidance for the decision whether a monitoring programme is required and how it should be designed. Its intention is to optimise the efforts for such a monitoring programme consistent with legal requirements and with the purpose of the radiation protection programme. Recommendations of international expert bodies and international experience with the practical application of these recommendations in radiation protection programmes have been considered in the development of this International Standard. Its application facilitates the exchanges of information between authorities, supervisory institutions and employers. The International Standard is not a substitute for legal requirements. In the International Standard, the word 'shall' is used to denote a requirement and no deviation is allowed. The word 'should' is used to denote a recommendation from which justified deviations are allowed. The word 'may' is used to denote permission

  8. Impact of the internal contamination monitoring for national and international regulations

    International Nuclear Information System (INIS)

    Gaburo, J.C.; Sordi, G.M.

    1996-01-01

    An evaluation of the internal radiation dose received by workers between 1984 and 1994 was performed, after a brief description of IPEN facility. The National and International Recommendation aims to reduce the workers' doses below 1/10 of the annual limits. The routine monitoring should be eliminated, if the individual annual dose is below 3/10 of the annual limits. In this case, only the operational monitoring should be maintained. In principle, the concept of restricted area should be reviewed, because, according to Publication 26 of ICRP, 1977, it should be a supervised area instead. The new concept of restricted area recommended by the Publication 60, ICRP 1991, should be adjusted accordingly. Thus, the classification used by the Commission-controlled areas and supervised areas will be with the foreseeable dose and not with the actual dose. When the individual annual dose is kept below 1/10 of the annual limits, the routine monitoring is not necessary, and only operational monitoring is needed. Finally, the future possible activities of the Individual Internal Dosimetry Laboratory at IPEN are discussed, after the elimination of individual monitoring. (authors). 8 refs

  9. Early-Stage Bioassay for Monitoring Radioactive Contamination in Living Livestock

    OpenAIRE

    Yamaguchi, Toshiro; Sawano, Kaita; Kishimoto, Miori; Furuhama, Kazuhisa; Yamada, Kazutaka

    2012-01-01

    Soil samples from the ground surface and feces and blood from a mixed-breed male pig were collected on April 10, 2011 at a farm within 20 km of the Fukushima Daiichi nuclear power plant. The radioactivity of each sample was measured using a Ge semiconductor detector. Despite the fact that the pig had been fed non-contaminated imported feed, 131I, 134Cs and 137Cs were detected in the feces, and 134Cs and 137Cs were detected in the blood clots. Because it is considerably difficult to measure ra...

  10. Induced Environment Contamination Monitor (IECM), air sampler - Results from the Space Transport System (STS-2) flight

    Science.gov (United States)

    Peters, P. N.; Hester, H. B.; Bertsch, W.; Mayfield, H.; Zatko, D.

    1983-01-01

    An investigation involving sampling the rapidly changing environment of the Shuttle cargo bay is considered. Four time-integrated samples and one rapid acquisition sample were collected to determine the types and quantities of contaminants present during ascent and descent of the Shuttle. The sampling times for the various bottles were controlled by valves operated by the Data Acquisition and Control System (DACS) of the IECM. Many of the observed species were found to be common solvents used in cleaning surfaces. When the actual volume sampled is taken into account, the relative mass of organics sampled during descent is about 20 percent less than during ascent.

  11. Sensitive Monitoring of Enterobacterial Contamination of Food Using Self-Propelled Janus Microsensors.

    Science.gov (United States)

    Pacheco, M; Jurado-Sánchez, B; Escarpa, A

    2018-02-20

    Food poisoning caused by bacteria is a major cause of disease and death worldwide. Herein we describe the use of Janus micromotors as mobile sensors for the detection of toxins released by enterobacteria as indicators of food contamination. The micromotors are prepared by a Pickering emulsion approach and rely on the simultaneous encapsulation of platinum nanoparticles for enhanced bubble-propulsion and receptor-functionalized quantum dots (QDs) for selective binding with the 3-deoxy-d-manno-oct-2-ulosonic acid target in the endotoxin molecule. Lipopolysaccharides (LPS) from Salmonella enterica were used as target endotoxins, which upon interaction with the QDs induce a rapid quenching of the native fluorescence of the micromotors in a concentration-dependent manner. The micromotor assay can readily detect concentrations as low as 0.07 ng mL -1 of endotoxin, which is far below the level considered toxic to humans (275 μg mL -1 ). Micromotors have been successfully applied for the detection of Salmonella toxin in food samples in 15 min compared with several hours required by the existing Gold Standard method. Such ultrafast and reliable approach holds considerable promise for food contamination screening while awaiting the results of bacterial cultures in a myriad of food safety and security defense applications.

  12. Laser Monitoring Of Phytoextraction Enhancement Of Lead Contaminated Soil Adopting EDTA And EDDS

    Science.gov (United States)

    Hassan, M.; Abdelhamied, M.; Hanafy, A. H.; Fantoni, R.; Harith, M. A.

    2011-09-01

    Removal of heavy metals (HMs) such as Pb from soil, wastewater, and air is essential for environment and human health. Phytoremediation is a well established technology based on the use of certain green plants for contaminants removal from soil, wastewater as well as air. Scented geranium, Pelargonium zonal, is a flowering plant recently used in HMs removal from contaminated soil. In the present work, EDTA (ethylenediaminetetraacetic acid) and EDDS (S, S-ethylenediaminedisuccinic acid) were used as chemical assistants providing higher Pb availability for extraction by plant roots. Lead was artificially added to the planting media, peatmoss, at different concentrations. Laser induced breakdown spectroscopy (LIBS) was used to follow up Pb relative concentrations in peatmoss as well as plant shoots, at different sampling times during the experiment period. Laser induced chlorophyll fluorescence (LICF), has been also used to evaluate chlorophyll formation and photosynthetic apparatus status in geranium plants. Such measurements were performed on geranium plants grown under various Pb levels, as well as EDTA and EDDS combinations. The combined effect of EDTA and EDDS was found to enhance Pb extraction with time. Good correlation was found between LICF results and chlorophyll (a) (Chl.a) concentrations in plant tissues extracted by chemical analysis.

  13. Contaminant monitoring of biota downstream of a radioactive liquid waste treatment facility, Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    Bennett, K.D.; Biggs, J.R.; Fresquez, P.R.

    1996-01-01

    Small mammals, plants, and sediments were sampled at one upstream location (Site 1) and two downstream locations (Site 2 and Site 3) from the National Pollution Discharge Elimination System (NPDES) outfall number-sign 051-051 in Mortandad Canyon, Los Alamos National Laboratory, Los Alamos, New Mexico. The purpose of the sampling was to identify radionuclides potentially present, to quantitatively estimate and compare the amount of radionuclide uptake at specific locations (Site 2 and Site 3) within Mortandad Canyon to an upstream site (Site 1), and to identify the primary mode (inhalation/ingestion or surface contact) of contamination to small mammals. Three composite samples of at least five animals per sample were collected at each site. The pelt was separated from the carcass of each animal and both were analyzed independently. In addition, three composite samples were also collected for plants and sediments at each site. Samples were analyzed for americium ( 241 Am), strontium ( 90 Sr), plutonium ( 238 Pu and 239 Pu), and total uranium (U). With the exception of total U, all mean radionuclide concentrations in small mammal carcasses and sediments were significantly higher at Site 2 than Site 1 or Site 3. No differences were detected in the mean radionuclide concentration of plant samples between sites. However, some radionuclide concentrations found at all three sites were higher than regional background. No differences were found between mean carcass radionuclide concentrations and mean pelt radionuclide concentrations, indicating that the two primary modes of contamination may be equally occurring

  14. Sedentary nestlings of Wood Stork as monitors of mercury contamination in the gold mining region of the Brazilian Pantanal

    Energy Technology Data Exchange (ETDEWEB)

    Nassif Del Lama, Silvia, E-mail: dsdl@ufscar.br [Laboratorio Genetica de Aves, Departamento de Genetica e Evolucao, Universidade Federal de Sao Carlos, Rodovia Washington Luis km 235, 13565-905 Sao Carlos, Sao Paulo (Brazil); Dosualdo Rocha, Cristiano [Laboratorio Genetica de Aves, Departamento de Genetica e Evolucao, Universidade Federal de Sao Carlos, Rodovia Washington Luis km 235, 13565-905 Sao Carlos, Sao Paulo (Brazil); Figueiredo Jardim, Wilson [Institute of Chemistry, State University of Campinas, P.O. Box 6154, 13083-970 Sao Paulo (Brazil); Tsai, Jo-Szu; Frederick, Peter Crawford [Department of Wildlife Ecology and Conservation, P.O. Box 110430, University of Florida, Gainesville, FL 32611 (United States)

    2011-11-15

    Sedentary organisms that are at top trophic levels allow inference about the level of local mercury contamination. We evaluated mercury contamination in feather tissue of nestling Wood Storks (Mycteria americana), sampled in different parts of the Brazilian Pantanal that were variably polluted by mercury releases from gold mining activities. Levels of mercury in feathers sampled in seven breeding colonies were determined by atomic absorption spectroscopy, and the mean value of mercury concentration was 0.557 {mu}g/g, dry weight (n=124), range 0.024-4.423 {mu}g/g. From this total sample, 21 feathers that represent 30% of nestlings collected in Porto da Fazenda and Tucum colonies, in the northern region, ranged from 1.0 to 4.43 {mu}g/g, dry weight (median value=1.87 {mu}g/g). We found significant differences among regions (H=57.342; p=0<0.05). Results suggest that permanently flooded areas, or along mainstream rivers are more contaminated by mercury than dry areas, regardless of the distance from the gold mining center, which is located in the northern Pantanal. Highest values found in nestlings feathers were similar to those found in feathers of adult birds and in tissues of adult mammals that are less sedentary and were captured in the same region of Pantanal. These findings indicate that mercury released has been biomagnified and it is present in high concentrations in tissues of top consumers. We suggest a program to monitor mercury availability in this ecosystem using sedentary life forms of top predators like Wood Storks or other piscivorous birds. - Highlights: Black-Right-Pointing-Pointer Sedentary stork nestlings were used for the first time to show local mercury contamination of Pantanal. Black-Right-Pointing-Pointer Differences were found among regions but they are not explained only by distance from the gold mining. Black-Right-Pointing-Pointer Permanently flooded areas and areas along mainstream rivers are more contaminated than dry areas. Black

  15. Sedentary nestlings of Wood Stork as monitors of mercury contamination in the gold mining region of the Brazilian Pantanal

    International Nuclear Information System (INIS)

    Nassif Del Lama, Silvia; Dosualdo Rocha, Cristiano; Figueiredo Jardim, Wilson; Tsai, Jo-Szu; Frederick, Peter Crawford

    2011-01-01

    Sedentary organisms that are at top trophic levels allow inference about the level of local mercury contamination. We evaluated mercury contamination in feather tissue of nestling Wood Storks (Mycteria americana), sampled in different parts of the Brazilian Pantanal that were variably polluted by mercury releases from gold mining activities. Levels of mercury in feathers sampled in seven breeding colonies were determined by atomic absorption spectroscopy, and the mean value of mercury concentration was 0.557 μg/g, dry weight (n=124), range 0.024–4.423 μg/g. From this total sample, 21 feathers that represent 30% of nestlings collected in Porto da Fazenda and Tucum colonies, in the northern region, ranged from 1.0 to 4.43 μg/g, dry weight (median value=1.87 μg/g). We found significant differences among regions (H=57.342; p=0<0.05). Results suggest that permanently flooded areas, or along mainstream rivers are more contaminated by mercury than dry areas, regardless of the distance from the gold mining center, which is located in the northern Pantanal. Highest values found in nestlings feathers were similar to those found in feathers of adult birds and in tissues of adult mammals that are less sedentary and were captured in the same region of Pantanal. These findings indicate that mercury released has been biomagnified and it is present in high concentrations in tissues of top consumers. We suggest a program to monitor mercury availability in this ecosystem using sedentary life forms of top predators like Wood Storks or other piscivorous birds. - Highlights: ► Sedentary stork nestlings were used for the first time to show local mercury contamination of Pantanal. ► Differences were found among regions but they are not explained only by distance from the gold mining. ► Permanently flooded areas and areas along mainstream rivers are more contaminated than dry areas. ► Mercury has been biomagnified in Pantanal and it is found in high concentrations in top

  16. Environmental and Water Quality Operational Studies. General Guidelines for Monitoring Contaminants in Reservoirs

    Science.gov (United States)

    1986-02-01

    espacially trte for the topics of sampling and analytical methods, statistical considerations, and the design of general water quality monitoring networks. For...and to the establishment and habitat differentiation of biological populations within reservoirs. Reservoir operatirn, esp- cially the timing...8217 % - - % properties of bottom sediments, as well as specific habitat associations of biological populations of reservoirs. Thus, such heterogeneities

  17. Micro Ion Mobility Sensor for In Situ Monitoring of Contaminated Groundwater

    Science.gov (United States)

    2012-01-01

    Inset 1: Portable ME GC-DMS monitor; Inset 2: Sending ME assembly to the groundwater well; Inset 3: Bees and their nest located on the cover of the...covered and locked for a period of a few months. During this time a wasp’s nest was built in the outer cover of the well, as shown in Insert 3 of

  18. Field sampling for monitoring, migration and defining the areal extent of chemical contamination

    International Nuclear Information System (INIS)

    Thomas, J.M.; Skalski, J.R.; Eberhardt, L.L.; Simmons, M.A.

    1984-01-01

    As part of two studies funded by the U.S. Nuclear Regulatory Commission and the USEPA, the authors have investigated field sampling strategies and compositing as a means of detecting spills or migration at commercial low-level radioactive and chemical waste disposal sites and bioassays for detecting contamination at chemical waste sites. Compositing (pooling samples) for detection is discussed first, followed by the development of a statistical test to determine whether any component of a composite exceeds a prescribed maximum acceptable level. Subsequently, the authors explore the question of optimal field sampling designs and present the features of a microcomputer program designed to show the difficulties in constructing efficient field designs and using compositing schemes. Finally, they propose the use of bioassays as an adjunct or replacement for chemical analysis as a means of detecting and defining the areal extent of chemical migration

  19. 3D resistivity method to monitor degradation of an organic contaminant in sand boxes

    Science.gov (United States)

    Fernandez, P. M.; Bloem, E.; Philippe, R.; French, H. K.

    2015-12-01

    Degradation of organic chemicals under various saturation conditions is a process highly relevant to protect groundwater. The redox potential drives the degradation of organic compounds. Its variation affects the water chemistry, gas release and responses of the geo-electrical signature. This study explores how non-invasive measurements sensitive to geo-electrical properties provides quantitative information about the in-situ redox situation. During this presentation, the preliminary results of a laboratory experiment to study the degradation of deicing chemicals with 3D resistivity and self-potential techniques, water samples will be shown. The experiment consists of sand boxes (1.0x0.5x0.4 m) to which both sides of each box is contaminated with propylene glycol, an aircraft deicing fluid, commonly used in Norwegian airports. Each source is placed near the water table with static conditions. At one side a conductor is placed, linking the contamination zone at the water table and the unsaturated zone with a low water content, to improve the degradation by facilitating the electron exchange. At the other side, degradation occurs under natural conditions. Each box is equipped with 288 electrodes, distributed on six faces to perform 3D resistivity measurements. In addition to the resistivity, self-potential measurements are taken from the sand surface. Six water wells are installed above and below the water table to provide more information on the degradation processes. Moreover, measurements of carbon dioxide on the surface are performed as higher concentrations are expected where the pollutant is degraded.

  20. Monitoring of plutonium contaminated solid waste streams. Chapter II: principles and theory of radiometric assay

    International Nuclear Information System (INIS)

    Birkhoff, G.; Bondar, L.; Notea, A.; Segal, Y.

    1977-01-01

    The interpretation of a count rate distribution obtained from radiometric assay of a given waste items population in terms of source strength distribution is discussed. A model for the evaluation of errors, arising from non uniform source density distribution (Pu) within the item volume and heterogeneity of matrix materials, is presented. Points concerning calibration procedures and representativity of reference materials are dealt with. Qualification procedures for possible monitoring systems are outlined on the basis of comparison with reference systems. The latter are composed of reference monitors based on high resolution gamma spectrometry and passive and active neutron techniques. The importance of information upon the elemental composition and density distribution of matrix materials for the interpretation of radiometric assay of solid wastes is stressed

  1. 2. All-Polish Seminar: Monitoring of Radioactive Environment Contamination Using ASS-500 and PMS Stations

    International Nuclear Information System (INIS)

    1998-01-01

    During last 10 years the modern system of radiological pollution monitoring has been developed in Poland. At the beginning it was composed of ASS-500 stations. At the end of 1995 five automatic PMS stations have been installed as the result of the collaboration between Polish and Danish governments. Several stations of both types were include later. The system is coordinated by Central Laboratory for Radiological Protection. The report reviews the meeting dedicated to problems and future developments of the system

  2. Monitoring the Extent of Contamination from Acid Mine Drainage in the Iberian Pyrite Belt (SW Spain Using Hyperspectral Imagery

    Directory of Open Access Journals (Sweden)

    Asuncion Riaza

    2011-10-01

    Full Text Available Monitoring mine waste from sulfide deposits by hyperspectral remote sensing can be used to predict surface water quality by quantitatively estimating acid drainage and metal contamination on a yearly basis. In addition, analysis of the mineralogy of surface crusts rich in soluble salts can provide a record of annual humidity and temperature. In fact, temporal monitoring of salt efflorescence from mine wastes at a mine site in the Iberian Pyrite Belt (Huelva, Spain has been achieved using hyperspectral airborne Hymap data. Furthermore, climate variability estimates are possible based on oxidation stages derived from well-known sequences of minerals, by tracing sulfide oxidation intensity using archive spectral libraries. Thus, airborne and spaceborne hyperspectral remote sensing data can be used to provide a short-term record of climate change, and represent a useful set of tools for assessing environmental geoindicators in semi-arid areas. Spectral and geomorphological indicators can be monitored on a regular basis through image processing, supported by field and laboratory spectral data. In fact, hyperspectral image analysis is one of the methods selected by the Joint Research Centre of the European Community (Ispra, Italy to study abandoned mine sites, in order to assess the enforcement of the European Mine Waste Directive (2006/21/EC of the European Parliament and of the Council 15 March 2006 on the management of waste from extractive industries (Official Journal of the European Union, 11 April 2006. The pyrite belt in Andalucia has been selected as one of the core mission test sites for the PECOMINES II program (Cracow, November 2005, using imaging spectroscopy; and this technique is expected to be implemented as a monitoring tool by the Environmental Net of Andalucía (REDIAM, Junta de Andalucía, Spain.

  3. Is the soil quality monitoring an effective tool in consumers' protection of agricultural crops from cadmium soil contamination?-a case of the Silesia region (Poland).

    Science.gov (United States)

    Piekut, Agata; Baranowska, Renata; Marchwińska-Wyrwał, Ewa; Ćwieląg-Drabek, Małgorzata; Hajok, Ilona; Dziubanek, Grzegorz; Grochowska-Niedworok, Elżbieta

    2017-12-16

    The monitoring of soil quality should be a control tool used to reduce the adverse health effects arising from exposure to toxic chemicals in soil through cultivated crop absorption. The aim of the study was to evaluate the effectiveness of the monitoring and control system of soil quality in Poland, in terms of consumer safety, for agricultural plants cultivated in areas with known serious cadmium contamination, such as Silesia Province. To achieve the objective, the contents of cadmium in soils and vegetables in the Silesia administrative area were examined. The obtained results were compared with the results of soil contamination from the quality monitoring of arable soil in Poland. The studies show a significant exceedance of the permissible values of cadmium in soil samples and the vegetables cultivated on that soil. The threat to consumer health is a valid concern, although this threat was not indicated by the results of the national monitoring of soil quality. The results indicated an unequal distribution of risk to consumers resulting from contaminated soil. Moreover, the monitoring systems should be designed at the local or regional scale to guarantee the safety of consumers of edible plants cultivated in the areas contaminated with cadmium.

  4. Development of portable and automatic smear sampler for measuring surface contamination

    International Nuclear Information System (INIS)

    Lee, Bong Jae; Chang, S. Y.; Kim, B. H.; Kim, J. S.; Lee, H. S.; Kim, C. K.; Swol, C. W.

    2000-12-01

    In measuring radioactive contamination in radiation controlled area of nuclear facility, the technical criteria to evaluate surface contamination level and to sample by indirect method was established in this paper. Radioactive materials always present on surface within operating nuclear facilities. Because of the presence of interfering radiation field, health physicists take smear samples to monitoring surface contamination according to routine monitoring program. But there are some problems like great errors and difference of personnel. Then, to solve them, The portable and automatic smear sampling apparatus was designed and fabricated

  5. Development of portable and automatic smear sampler for measuring surface contamination

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Bong Jae; Chang, S. Y.; Kim, B. H.; Kim, J. S.; Lee, H. S.; Kim, C. K.; Swol, C. W

    2000-12-01

    In measuring radioactive contamination in radiation controlled area of nuclear facility, the technical criteria to evaluate surface contamination level and to sample by indirect method was established in this paper. Radioactive materials always present on surface within operating nuclear facilities. Because of the presence of interfering radiation field, health physicists take smear samples to monitoring surface contamination according to routine monitoring program. But there are some problems like great errors and difference of personnel. Then, to solve them, The portable and automatic smear sampling apparatus was designed and fabricated.

  6. The Thirty Years’ Results of Radiation Hygienic Monitoring of Tula Region territories contaminated due to the Chernobyl NPP accident

    Directory of Open Access Journals (Sweden)

    V. V. Boldyreva

    2016-01-01

    Full Text Available Over 50% of Tula Region areas were contaminated after the Chernobyl NPP accident. The article provides the thirty years’ results of radiation hygienic monitoring of the Chernobyl accidental fallout - affected areas in Tula Region. The radiation situation is assessed at the initial accidental period and at the current stage. The initial levels of gamma - radiation dose intensity (up to 35 mcSv/hr are identified for the period of the “iodine” hazard along with the tabular data on the dose intensity relative stabilization by the beginning of August 1986 due to iodine-131 decay. The information is presented regarding iodine-131 tentative maximum permissible level exceedance in the dairy products of the two most contaminated regional areas - Plavskoye and Arsenievskoye. The article also provides the laboratory data on the total beta - activity in the foodstuffs in 1986-1987 and cesium-137 maximum permissible level exceedence in 1986. The radionuclide maximum permissible level exceedances in foodstuffs were registered only in 1986 due to the plants surface contamination whereas in the forest mushrooms those exceedances were repeatedly found until 2004. The black earths and grey forest soils had a benign impact upon the intensity of the radionuclide transfer into plants which resulted in the formation of internal radiation doses.At the current stage, the content of cesium-137 and strontium- 90 in the foodstuffs can only be quantified by a radiochemical method. The table covers all the districts within the boundaries of radiation contaminated zones. The radiochemical studies indicate the main dose - forming products. The article contains the table of internal and external radiation doses of the population in Plavsk town over 1986-1990 and displays the factors impacting population’s internal and external exposure. The Chernobyl - affected exposure dose of the population is mostly attributed to the external radiation and, for over twenty years, it

  7. Works carried out to correct and monitor water contamination; Actuaciones para la correccion y el seguimiento de la contaminacion hidrica

    Energy Technology Data Exchange (ETDEWEB)

    Ayora, C.; Guijarro, A.; Domenech, C.; Fernandez, I.; Gomez, P.; Manzano, M.; Mora, A.; Moreno, L.; Navarrete, P.; Sanchez, M.; Serrano, J.

    2001-07-01

    The works carried out to correct or control the impact of the Aznalcollar mine spill on water is described. The chapter refers both to the surface water retained in Entremuros between walls area since the very first moment, to the Guadiamar river water, and to groundwater in the aquifers affected by the spill. Most of the water retained in Entremuros after the spill was treated in situ by the IGME in an emergency plant, and afterwards was evacuated to the Guadalquivir river through the Canal de Aguas Minimas (low water canal). The water was cleaned by adding sodium carbonate and sodium hydroxide to small volumes which allowed to settle afterwards. The treatment and evacuation activities lasted around one month. The impact of the spill on the river water resulted in the immediate acidification, reaching pH values around 4 between the failed dam and Aznalcazar village. Also, dissolved oxygen was eliminated, suspended solids increased up to 30 g/L and dissolved heavy metals reached concentrations close to those of the original spilled water. However, after a few days the dissolved oxygen concentrations were recovered, most of the solid particles settled down, and pH started slowly to increase. the fast collection of the mud settled down on the river margins prevented the continuous contamination of the river. However, the Agrio river sector between the failed dam and the Agrio-Guadiamar river junction is still contaminated with acid and heavy metals. It is assumed the discharge of contaminated water from the alluvial aquifer into the river bed. To the s of the Agrio-Guadiamar junction the main threat to river water quality is the disposal of urban and agro-industrial untreated waste water. Looking to the impact on groundwater, only the above mentioned sector of the Agrio river alluvial aquifer is widely contaminated. This pollution is probably due both to the 1998 spill and the previous leakage from the tailings dam, and it is presently under study. Between the Agrio

  8. Lead and strontium isotopes as monitors of anthropogenic contaminants in the surficial environment: Chapter 12

    Science.gov (United States)

    Ayuso, Robert A.; Foley, Nora K.

    2018-01-01

    Isotopic discrimination can be an effective tool in establishing a direct link between sources of Pb contamination and the presence of anomalously high concentrations of Pb in waters, soils, and organisms. Residential wells supplying water containing up to 1600 ppb Pb to houses built on the former Mohr orchards commercial site, near Allentown, Pennsylvania, United States, were evaluated to discern anthropogenic from geogenic sources. Pb and Sr isotopic data and REE data were determined for waters from residential wells, test wells (drilled for this study), and surface waters from pond and creeks. Local soils, sediments, bedrock, Zn-Pb mineralization and coal were also analyzed, together with locally used Pb-As pesticide. Pb isotope data for residential wells, test wells, and surface waters show substantial overlap with Pb data reflecting anthropogenic actions (e.g., burning fossil fuels, industrial and urban processing activities). Limited contributions of Pb from bedrock, soils, and pesticides are evident. High Pb concentrations in the residential waters are likely related to Pb in groundwater accumulating in sediment in the residential water tanks. The Pb isotope features of waters in underlying shallow aquifers that supply residential wells in the region are best interpreted as reflecting a legacy of anthropogenic Pb rather than geogenic Pb.

  9. Monitoring emerging contaminants in the drinking water of Milan and assessment of the human risk.

    Science.gov (United States)

    Riva, Francesco; Castiglioni, Sara; Fattore, Elena; Manenti, Angela; Davoli, Enrico; Zuccato, Ettore

    2018-04-01

    Emerging Contaminants (ECs) are ubiquitous in waters, arousing concern because of their potential risks for human health and the environment. This study investigated the presence of multiple classes of ECs in 21 wells over the drinking water network of Milan, in the most inhabited and industrialized area of Italy, and assessed the risks for consumers. Samples were analyzed using liquid chromatography coupled to mass spectrometry. Human risk assessment (HRA) was conducted by comparing the measured concentrations with drinking water thresholds from guidelines or calculated in this study; first considering the exposure to each single EC and then the entire mixture. Thirteen ECs were measured in the low ng/L range, and were generally detected in less than half of the wells. Pharmaceuticals, perfluorinated substances, personal care products, and anthropogenic markers were the most frequently detected. The results of the HRA excluded any risks for consumers in each scenario considered. This is one of the most comprehensive studies assessing the presence of a large number of ECs in the whole drinking water network of a city, and the risks for human health. Results improve the limited information on ECs sources and occurrence in drinking water and help establishing guidelines for regulatory purposes. Copyright © 2018 Elsevier GmbH. All rights reserved.

  10. Recent developments for field monitoring of alpha-emitting contaminants in the environment

    International Nuclear Information System (INIS)

    Ahlquist, A.J.; Umbarger, C.J.; Stoker, A.K.

    1978-01-01

    The Los Alamos Scientific Laboratory has adapted two field methods to assess rapidly locations and concentrations of alpha-emitting contaminants in soil. (1) A ZnS scintillator is used for gross-alpha measurements on soil samples. Sample preparation and the calibration and detection limits of the system are discussed, and results of gross-alpha analysis are compared with results of a 239 Pu radiochemistry analysis. (2) A Phoswich detector is used as a field survey instrument because it can detect lower levels of radioactivity than the FIDLER probe. The electronics are carried in a truck and the probe is connected by an umbilical cord. The system electronics are calibrated with an energy window of 12-40 keV which allows detection of Pu, Am, Th (using daughter L X-rays of the alpha-emitters) and 137 Cs (using its daughter 32 keV X-rays). The bremsstrahlung from 90 Sr can also be detected. (author)

  11. Evaluation of HPGe spectrometric devices in monitoring the level of radioactive contamination in metallurgical industry

    Energy Technology Data Exchange (ETDEWEB)

    Petrucci, A., E-mail: andrea.petrucci@enea.it [ENEA – Istituto Nazionale di Metrologia delle Radiazione Ionizzanti, Rome (Italy); Arnold, D.; Burda, O. [PTB – Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig (Germany); De Felice, P. [ENEA – Istituto Nazionale di Metrologia delle Radiazione Ionizzanti, Rome (Italy); Garcia-Toraño, E.; Mejuto, M.; Peyres, V. [CIEMAT – Laboratorio de Metrologia de Radiaciones Ionizantes, Avda. Complutense 40, 28040 Madrid (Spain); Šolc, J. [CMI – Czech Metrology Institute, Radiova 1a, 102 00 Praha 10 (Czech Republic); Vodenik, B. [IJS – Laboratory for Radioactivity Measurements, Institute Jožef Stefan, Jamova 39, 1000 Ljubljana Slovenia (Slovenia)

    2015-10-11

    This paper presents the results of the tests of High Purity Germanium (HPGe) based gamma spectrometers employed for radioactivity control carried out on a daily basis in steel factories. This new application of this type of detector is part of the Joint Research Project (JRP) MetroMETAL supported by the European Metrology Research Programme (EMRP). The final purpose of the project was the improvement and standardisation of the measurement methods and systems for the control of radioactivity of recycled metal scraps at the beginning of the working process and for the certification of the absence of any radioactive contamination above the clearance levels (IAEA-TECDOC-8S5) in final steel products, Clearance levels for radionuclides in solid materials: application of exemption principles). Two prototypes based on HPGe detectors were designed and assembled to suit the needs of steel mills which had been examined previously. The evaluation of the two prototypes, carried out at three steel factories with standard sources of {sup 60}Co, {sup 137}Cs, {sup 192}Ir, {sup 226}Ra and {sup 241}Am in three different matrices (slag, fume dust and cast steel) and with samples provided on-site by the factories, was successful. The measurements proved the superiority of the prototypes over the scintillation detectors now commonly used regarding energy resolution and multi-nuclide identification capability. The detection limits were assessed and are presented as well.

  12. Implementation of distributed computing system for emergency response and contaminant spill monitoring

    International Nuclear Information System (INIS)

    Ojo, T.O.; Sterling, M.C.Jr.; Bonner, J.S.; Fuller, C.B.; Kelly, F.; Page, C.A.

    2003-01-01

    The availability and use of real-time environmental data greatly enhances emergency response and spill monitoring in coastal and near shore environments. The data would include surface currents, wind speed, wind direction, and temperature. Model predictions (fate and transport) or forensics can also be included. In order to achieve an integrated system suitable for application in spill or emergency response situations, a link is required because this information exists on many different computing platforms. When real-time measurements are needed to monitor a spill, the use of a wide array of sensors and ship-based post-processing methods help reduce the latency in data transfer between field sampling stations and the Incident Command Centre. The common thread linking all these modules is the Transmission Control Protocol/Internet Protocol (TCP/IP), and the result is an integrated distributed computing system (DCS). The in-situ sensors are linked to an onboard computer through the use of a ship-based local area network (LAN) using a submersible device server. The onboard computer serves as both the data post-processor and communications server. It links the field sampling station with other modules, and is responsible for transferring data to the Incident Command Centre. This link is facilitated by a wide area network (WAN) based on wireless broadband communications facilities. This paper described the implementation of the DCS. The test results for the communications link and system readiness were also included. 6 refs., 2 tabs., 3 figs

  13. Elimination of quarterly urinalysis of radiation workers based on detection capability of portal monitors for internal contamination

    International Nuclear Information System (INIS)

    Ramanuja, Jayalakshmi

    2012-01-01

    Covidien is a radiopharmaceutical manufacturing company in Missouri, USA. The facility produces radionuclides for diagnostic and therapeutic use. The radionuclides of interest, 123 I, 67 Ga, 99 Mo, 99m Tc, 201 Tl, 111 In, and 131 I are fairly short lived with the exception of 51 Cr. The operating license document for the company mandated quarterly urinalysis (bioassay) of all radiation workers in the facility. This was labor intensive and did not enhance the quality of radiation protection program. Nuclear Regulatory Commission (NRC) required a technical basis to prove that there was no compromise in the radiological safety and accurate dose assessment in the event of internal contamination of radiation workers if quarterly urinalysis was discontinued. Measurements in a phantom, gamma spectroscopy analysis, as well as calculations showed that there was no need to perform quarterly urinalysis and that portal monitors and other radiological controls were sufficient to detect any chronic or acute intake of radioactivity by radiation workers. Technical evaluation showed Portal monitors can detect an Effective Dose Equivalent of 0.1 mSv (10 mrem) in a year. NRC allowed revision of operating license document and operating procedures to discontinue quarterly urinalysis. (author)

  14. Development of direct reading dosimeters for the dose 0-3 mSv and 0-5 mSv ranges for personnel monitoring

    International Nuclear Information System (INIS)

    Gaikwad, P.V.; Shirkar, Y.B.; Patil, A.S.; Madgaonkar, P.P.; Kale, K.L.; Guhagarkar, H.V.; Gandhi, D.P.; Gupta, S.K.; Kothiyal, G.P.; Sahni, V.C.

    1998-01-01

    Direct reading dosimeters (DRDs) are widely used to measure cumulative dose received by personnel working at nuclear reactor sites or in other environment having x- and gamma rays. A DRD operates on the principle of gold leaf electroscope, and is a small, rugged, hermetically sealed, self reading type device easily carried by an individual in his pocket. The development of dosimeters suitable for the dose ranges 0-3 mSv and 0-5 mSv is reported

  15. Highlights from the SoilCAM project: Soil Contamination, Advanced integrated characterisation and time-lapse Monitoring

    Science.gov (United States)

    French, H. K.; van der Zee, S. E. A. T. M.; Wehrer, M.; Godio, A.; Pedersen, L. B.; Toscano, G.

    2012-04-01

    The SoilCAM project (Soil Contamination, Advanced integrated characterisation and time-lapse Monitoring 2008-2012, EU-FP7-212663) is aimed at improving current methods for monitoring contaminant distribution and biodegradation in the subsurface. At two test sites, Oslo airport Gardermoen in Norway and the Trecate site in Italy, a number of geophysical techniques, lysimeter and other soil and water sampling techniques as well as numerical flow and transport modelling have been combined at different scales in order to characterise flow transport processes in the unsaturated and saturated zones. Laboratory experiments have provided data on physical and bio-geo-chemical parameters for use in models and to select remediation methods. The geophysical techniques were used to map geological heterogeneities and also conduct time-lapse measurements of processes in the unsaturated zone. Both cross borehole and surface electrodes were used for electrical resistivity and induced polarisation surveys. The geophysical surveys showed clear indications of areas highly affected by de-icing chemicals along the runway at Oslo airport. The time lapse measurements along the runway at the airport show infiltration patterns during snowmelt and are used to validate 2D unsaturated flow and transport simulations using SUTRA. The Orchestra model is used to describe the complex interaction between bio-geo-chemical processes in a 1D profile along the runway. The presence of installations such as a membrane along the runway highly affects the flow pattern and challenges the capacity of the numerical code. Smaller scale field site measurements have revealed the increase of iron and manganese during degradation of de-icing chemicals. The use of Nitrate to increase red-ox potential was tested, but results have not been analysed yet. So far it cannot be concluded that degradation process can be quantified indirectly by geophysical monitoring. At the Trecate site a combination of georadar, electrical

  16. GE/NOMADICS IN-WELL MONITORING SYSTEM FOR VERTICAL PROFILING OF DNAPL CONTAMINANTS

    Energy Technology Data Exchange (ETDEWEB)

    Ronald E. Shaffer; Radislav Potyralio; Joseph Salvo; Timothy Sivavec; Lloyd Salsman

    2003-04-01

    This report describes the Phase I effort to develop an Automated In Well Monitoring System (AIMS) for in situ detection of chlorinated volatile organic compounds such as trichloroethylene (TCE) and tetrachloroethylene (PCE) in groundwater. AIMS is composed of 3 primary components: (a) sensor probe, (b) instrument delivery system, and (c) communication/recharging station. The sensor probe utilizes an array of thickness shear mode (TSM) sensors coated with chemically-sensitive polymer films provides a low-cost, highly sensitive microsensor platform for detection and quantification. The instrument delivery system is used to position the sensor probe in 2 inch or larger groundwater monitoring wells. A communication/recharging station provides wireless battery recharging and communication to enable a fully automated system. A calibration curve for TCE in water was built using data collected in the laboratory. The detection limit of the sensor probe was 6.7 ppb ({micro}g/L) for TCE in water. A preliminary field test was conducted at a GE remediation location and a pilot field test was performed at the DOE Savannah River Site (SRS). The AIMS system was demonstrated in an uncontaminated (i.e., ''clean'') 2-inch well and in a 4-inch well containing 163.5 ppb of TCE. Repeat measurements at the two wells indicated excellent day-to-day reproducibility. Significant differences in the sensor responses were noted between the two types of wells but they did not closely match the laboratory calibration data. The robustness of the system presented numerous challenges for field work and limited the scope of the SRS pilot field test. However, the unique combination of trace detection (detection limits near the MCL, minimum concentration level) and size (operations in 2-inch or larger groundwater wells) is demonstration of the promise of this technology for long-term monitoring (LTM) applications or rapid site characterization. Using the lessons learned from the

  17. Technical Basis for Implementation of the PCM-1B for Personnel Release at Tank Farms

    International Nuclear Information System (INIS)

    BROWN, R.L.

    1999-01-01

    The purpose of this document is to define the technical basis and implementing guidelines for using automated personnel contamination monitors, such as the PCM-1B, at the River Protection Project (RPP) in lieu of performing a hand-held instrument followed by a PCM-1B survey for personnel release from contamination areas requiring a beta-gamma whole body survey. This document provides the basis for full implementation of the PCM-1B release survey, without the supplemental hand and foot survey, as currently implemented at RPP. This document applies only to RPP facilities. This document does not provide the technical basis for determining the equivalency of an automated system to hand-held instruments, or to the effective counting capability of automated systems as such technical determinations are contained in TBTN: GDGH-9604-RLS-0015

  18. Application of Polar Organic Chemical Integrative Sampler (POCIS) to monitor emerging contaminants in tropical waters.

    Science.gov (United States)

    Bayen, Stéphane; Segovia, Elvagris; Loh, Lay Leng; Burger, David F; Eikaas, Hans S; Kelly, Barry C

    2014-06-01

    Tools specifically validated for tropical environments are needed to accurately describe the behavior of chemical contaminants in tropical ecosystems. In the present study, sampling rates (Rs) were determined for the commercial pharmaceutical-type Polar Organic Chemical Integrative Sampler (POCIS) with a 45.8cm(2) exposure surface for 35 Pharmaceutically Active Compounds (PhACs) and Endocrine Disrupting Compounds (EDCs), of which eight compounds (albuterol, atorvastatin, diltiazem, dilantin, enalapril, norfluoxetine, risperidone and warfarin) were reported for the first time. These sampling rates were measured in an outdoor laboratory calibration setup to best capture diurnal tropical temperature variations (29±3°C). The effect of stirring and salinity was investigated. For all compounds, the sampling rates were higher under stirred conditions as compared to quiescent conditions. Calibration results in the presence of 30g sodium chloride support that the effects of salinity on POCIS sampling rates are compound-specific. Comparisons between Time-Weight Average (TWA) water concentrations using POCIS and spot sample levels in the field (2 lake and 1 mangrove estuary sites) are presented. Results showed that POCIS TWA concentrations were in agreement with spot sample concentrations for these aquatic systems. Results indicate that POCIS can be used to effectively measure the TWA concentration for a range of PhACs and EDCs in tropical waters. However, based on the results from mass balance and field deployments, POCIS did not appear suitable for compounds with a low mass balance recovery during calibration (e.g. triclosan and linuron in this study). Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Applications of UAVs to Measurement and Monitoring of Anthropogenic Contamination of an Urban Wildlife Preserve

    Science.gov (United States)

    Higa, E.; Valencia, D.; Hunt, A.

    2017-12-01

    Over the past decade, the use of unmanned aerial vehicles (UAV's) has seen unprecedented growth in diverse research areas due to advances in UAV hardware and reduced total operating costs. These developments have given environmental investigators a new aerial data acquisition technique that can be used to not only survey large areas of terrain in a time-efficient and cost-effective manner but can be used to gather previously almost unattainable air quality data. Vertically resolved profiles of air pollutant data can be readily constructed. This project's goal is to produce a time resolved (seasonal) aerial survey of a 150-acre section from a 1300-acre ecologically diverse park of bottomland forests, wetlands and prairies. This ecosystem provides abundant habitats for a diverse wildlife community. This section was chosen due to its close proximity to the city landfill located 0.5 miles due north from the chosen section. The process of collecting UAV aerial images at a constant altitude of ( 200ft) on a bi-monthly basis (for a period of 6 months) has commenced. The UAV has been fitted with a custom made mount to secure an Ultrafine Particle (UFP) counter; this is providing information on UFP levels over the study area as a proxy for airborne particle inputs to the site. Sediment samples will be taken from several runoff ponds within the survey area to evaluate possible anthropogenic contamination of the park . Post processing imaging software, DroneDeploy, is being used to create an orthomosaic, topographic surface and 3D model that can be integrated with GIS platforms to create a comprehensive and cohesive multi-layered data set. Data sets of this nature will provide information on temporally constrained sources of runoff material to the pond areas in the preserve.

  20. Sensitive Multi-Species Emissions Monitoring: Infrared Laser-Based Detection of Trace-Level Contaminants

    Energy Technology Data Exchange (ETDEWEB)

    Steill, Jeffrey D. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Huang, Haifeng [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Hoops, Alexandra A. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Patterson, Brian D. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Birtola, Salvatore R. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Jaska, Mark [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Strecker, Kevin E. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Chandler, David W. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Bisson, Soott [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2014-09-01

    This report summarizes our development of spectroscopic chemical analysis techniques and spectral modeling for trace-gas measurements of highly-regulated low-concentration species present in flue gas emissions from utility coal boilers such as HCl under conditions of high humidity. Detailed spectral modeling of the spectroscopy of HCl and other important combustion and atmospheric species such as H 2 O, CO 2 , N 2 O, NO 2 , SO 2 , and CH 4 demonstrates that IR-laser spectroscopy is a sensitive multi-component analysis strategy. Experimental measurements from techniques based on IR laser spectroscopy are presented that demonstrate sub-ppm sensitivity levels to these species. Photoacoustic infrared spectroscopy is used to detect and quantify HCl at ppm levels with extremely high signal-to-noise even under conditions of high relative humidity. Additionally, cavity ring-down IR spectroscopy is used to achieve an extremely high sensitivity to combustion trace gases in this spectral region; ppm level CH 4 is one demonstrated example. The importance of spectral resolution in the sensitivity of a trace-gas measurement is examined by spectral modeling in the mid- and near-IR, and efforts to improve measurement resolution through novel instrument development are described. While previous project reports focused on benefits and complexities of the dual-etalon cavity ring-down infrared spectrometer, here details on steps taken to implement this unique and potentially revolutionary instrument are described. This report also illustrates and critiques the general strategy of IR- laser photodetection of trace gases leading to the conclusion that mid-IR laser spectroscopy techniques provide a promising basis for further instrument development and implementation that will enable cost-effective sensitive detection of multiple key contaminant species simultaneously.

  1. Monitoring and modeling of contaminant loads and levels in Norwegian sea 2011

    International Nuclear Information System (INIS)

    Green, Norman W.; Heldal, Hilde Elise; Maage, Amund; Aas, Wenche; Graefert, Torbjoern; Schrum, Corinna; Boitsov, Stepan; Breivik, Knut; Iosjpe, Mikhail; Yakushev, Evgeniy; Skogen, Morten; Hoegaasen, Tore; Eckhardt, Sabine; Christiansen, Anne Bjoerkenes; Daae, Kjersti L.; Durand, Dominique; Ledang, Anna Birgitta; Jaccard, Pierre Francois

    2012-01-01

    This report describes the calculation of the supply of oil, hazardous chemicals and radioactive substances from seven sources of seven regions in the Norwegian part of the Norwegian Sea. The data from the various sources used to calculate the concentrations of pollutants in the water column throughout the defined area of the Norwegian Sea (3 dimensions) and calculate the transport of Hg, PCB153 and BaP in and out of each of the seven regions. This transport flux is huge compared with inputs and will alternately be a net source or net sink of each region. The main feature is that the supply is dominated by the fallout from the atmosphere is balanced by decomposition and sedimentation in the water column plus exports / imports from adjacent waters. It is relatively small supply of hazardous substances. With few exceptions, for the supply of air the biggest contribution of mercury, lead, cadmium, chromium, arsenic, PCBs (PCB-153) and PAH (benzo [a] pyrene) to all regions. Exception contributions of land for chromium in mid-Norway and contributions from seabed for lead and chromium from more central parts of the Norwegian Sea. Ship traffic dominates regard. supply of oil. Supply air from the major contribution of radionuclides plutonium-239 240 and strontium-90 in the eastern part of the Norwegian Sea. Otherwise, Sellafield is the dominant source. Contaminants in sediment and cod were largely of low to moderate concentrations. The concentration of radioactive substances in water, sediment and cod were low and comparable with results from other studies in the Norwegian Sea. There are still large gaps in knowledge and uncertainties in both the data and the estimates of supplies. It is especially important to improved figures for inflows into the oceans via air and enhancement of the marine transport and dispersion models.(eb)

  2. Country report for the regional (RCA) training workshop on contamination monitoring

    International Nuclear Information System (INIS)

    Shantha, T.H.S.

    1997-01-01

    The Atomic Energy Authority (AEA) is the organization in Sri Lanka responsible for the regulatory and development of applications in nuclear technology. AEA was established in 1969 by the AEA Act No. 19 of 1969 and at present it is under the Ministry of Science, Technology and Human Resources Development. As a developing country, Sri Lanka still needs technical assistance to support the development of application in nuclear technology. So far this country doesn't have any type of nuclear reactors. Most of activities in Sri Lanka are in health sector using x-ray and radioisotopes for diagnostic and therapeutic purposes. In addition to that few number of radioisotopes are used in industrial and research institutes. In this paper, the following items are described: radiation protection activities, emergency preparation and planning, food testing program, and nuclear technique in monitoring industrial pollution. (G.K.)

  3. Country report for the regional (RCA) training workshop on contamination monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Shantha, T H.S. [Atomic Energy Authority (Sri Lanka)

    1997-06-01

    The Atomic Energy Authority (AEA) is the organization in Sri Lanka responsible for the regulatory and development of applications in nuclear technology. AEA was established in 1969 by the AEA Act No. 19 of 1969 and at present it is under the Ministry of Science, Technology and Human Resources Development. As a developing country, Sri Lanka still needs technical assistance to support the development of application in nuclear technology. So far this country doesn`t have any type of nuclear reactors. Most of activities in Sri Lanka are in health sector using x-ray and radioisotopes for diagnostic and therapeutic purposes. In addition to that few number of radioisotopes are used in industrial and research institutes. In this paper, the following items are described: radiation protection activities, emergency preparation and planning, food testing program, and nuclear technique in monitoring industrial pollution. (G.K.)

  4. Technical basis for implementing the use of the PCM-1B for personnel releases at tank farms

    International Nuclear Information System (INIS)

    Brown, R.L.

    1996-01-01

    Currently, Tanks Farms Transition Projects require personnel to perform a whole body survey with portable survey instrumentation prior to entering an automated counting system capable of performing a whole body survey. This practice is redundant since automated whole body survey devices are, in most cases, more sensitive and are less likely to be used incorrectly than portable instrumentation. Additionally, Article 221.2 of the Hanford Site Radiological Control Manual (HSRCM-1) states ''Monitoring for contamination should be performed using frisking equipment that under laboratory conditions can detect total contamination of at least the values specified in Table 2-2.'' Based on this criteria implementing the use of an automated whole body survey device would save significant time, money and reduce the current crowding and potential loss of contamination control that now occurs during peak times at step off pads. This document describes implementation process for applying PCM-1B instruments to perform personnel release surveys

  5. Innovative Methods for Integrating Knowledge for Long-Term Monitoring of Contaminated Groundwater Sites: Understanding Microorganism Communities and their Associated Hydrochemical Environment

    Science.gov (United States)

    Mouser, P. J.; Rizzo, D. M.; Druschel, G.; O'Grady, P.; Stevens, L.

    2005-12-01

    This interdisciplinary study integrates hydrochemical and genome-based data to estimate the redox processes occurring at long-term monitoring sites. Groundwater samples have been collected from a well-characterized landfill-leachate contaminated aquifer in northeastern New York. Primers from the 16S rDNA gene were used to amplify Bacteria and Archaea in groundwater taken from monitoring wells located in clean, fringe, and contaminated locations within the aquifer. PCR-amplified rDNA were digested with restriction enzymes to evaluate terminal restriction fragment length polymorphism (T-RFLP) community profiles. The rDNA was cloned, sequenced, and partial sequences were matched against known organisms using the NCBI Blast database. Phylogenetic trees and bootstrapping were used to identify classifications of organisms and compare the communities from clean, fringe, and contaminated locations. We used Artificial Neural Network (ANN) models to incorporate microbial data with hydrochemical information for improving our understanding of subsurface processes.

  6. Concentration of elements in whole-body fish, fish fillets, fish muscle plugs, and fish eggs from the 2008 Missouri Department of Conservation General Contaminant Monitoring Program

    Science.gov (United States)

    May, Thomas W.; Walther, Michael J.; Brumbaugh, William G.; McKee, Michael J.

    2009-01-01

    This report presents the results of a contaminant monitoring survey conducted annually by the Missouri Department of Conservation to examine the levels of selected elemental contaminants in whole-body fish, fish fillets, fish muscle plugs, and fish eggs. Whole-body, fillet, or egg samples of catfish (Ictalurus punctatus, Ictalurus furcatus, Pylodictis olivaris), largemouth bass (Micropterus salmoides), walleye (Sander vitreus), crappie (Pomoxis annularis, Pomoxis nigromaculatus), shovelnose sturgeon (Scaphirhynchus platorynchus), northern hog sucker (Hypentelium nigricans), and Missouri saddled darter (Etheostoma tetrazonum) were collected from 23 sites as part of the Missouri Department of Conservation's Fish Contaminant Monitoring Program. Fish dorsal muscle plugs also were collected from walleye (Sander vitreus) at one of the sites.

  7. Concentrations of elements in fish fillets, fish muscle plugs, and crayfish from the 2007 Missouri Department of Conservation General Contaminant Monitoring Program

    Science.gov (United States)

    May, Thomas W.; Walther, Michael J.; Brumbaugh, William G.; McKee, Michael J.

    2009-01-01

    This report presents the results of a contaminant monitoring survey conducted annually by the Missouri Department of Conservation to examine the levels of selected elemental contaminants in fish fillets, fish muscle plugs, and crayfish. Fillets of channel catfish (Ictalurus punctatus), bass (Micropterus salmoides, Micropterus dolomieu, Morone chrysops), walleye (Sander vitreus), common carp (Cyprinus carpio), lake sturgeon (Acipenser fulvescens), northern hog sucker (Hypentelium nigricans), and rainbow trout (Oncorhynchus mykiss) were collected from 21 sites as part of the Department's Fish Contaminant Monitoring Program. Long-pincered crayfish (Orconectes longidigitus) were collected from one site to assess trophic transfer of metals to fish. Fish muscle plugs were collected from smallmouth bass (Micropterus dolomieu) at two different locations from one site.

  8. A potential approach for monitoring drinking water quality from groundwater systems using organic matter fluorescence as an early warning for contamination events

    DEFF Research Database (Denmark)

    Stedmon, Colin; Seredyńska-Sobecka, Bożena; Boe-Hansen, Rasmus

    2011-01-01

    at levels equivalent to the addition of 60 μg C/L in drinking water with a TOC concentration of 3.3 mg C/L. The results of this study suggest that these types of drinking water systems, which are vulnerable to microbial contamination due to the lack of disinfectant treatment, can be easily monitored using...

  9. Evaluate the use of space monitoring methods for the study of the ecological state of the territory contaminated with heavy metals

    Directory of Open Access Journals (Sweden)

    Kroik G.A.

    2010-06-01

    Full Text Available Possibilities of modern Earth remote sensing systems are investigated in the space environmental monitoring of areas, contaminated with heavy metals, and the best of them are identified. The most informative E-field radiation spectrum zones for remote indication of heavy metals are identified and the special spectral indexes are offered.

  10. Field tests of a chemiresistor sensor for in-situ monitoring of vapor-phase contaminants

    Science.gov (United States)

    Ho, C.; McGrath, L.; Wright, J.

    2003-04-01

    An in-situ chemiresistor sensor has been developed that can detect volatile organic compounds in subsurface environmental applications. Several field tests were conducted in 2001 and 2002 to test the reliability, operation, and performance of the in-situ chemiresistor sensor system. The chemiresistor consists of a carbon-loaded polymer deposited onto a microfabricated circuit. The polymer swells reversibly in the presence of volatile organic compounds as vapor-phase molecules absorb into the polymer, causing a change in the electrical resistance of the circuit. The change in resistance can be calibrated to known concentrations of analytes, and arrays of chemiresistors can be used on a single chip to aid in discrimination. A waterproof housing was constructed to allow the chemiresistor to be used in a variety of media including air, soil, and water. The integrated unit, which can be buried in soils or emplaced in wells, is connected via cable to a surface-based solar-powered data logger. A cell-phone modem is used to automatically download the data from the data logger on a periodic basis. The field tests were performed at three locations: (1) Edwards Air Force Base, CA; (2) Nevada Test Site; and (3) Sandia's Chemical Waste Landfill near Albuquerque, NM. The objectives of the tests were to evaluate the ruggedness, longevity, operation, performance, and engineering requirements of these sensors in actual field settings. Results showed that the sensors could be operated continuously for long periods of time (greater than a year) using remote solar-powered data-logging stations with wireless telemetry. The sensor housing, which was constructed of 304 stainless steel, showed some signs of corrosion when placed in contaminated water for several months, but the overall integrity was maintained. The detection limits of the chemiresistors were generally found to be near 0.1% of the saturated vapor pressure of the target analyte in controlled laboratory conditions (e

  11. Solid sample atomic absorption spectroscopy in a chemical contaminant monitoring pilot project

    Energy Technology Data Exchange (ETDEWEB)

    Klein, J.; Schmidt, H.; Dirscherl, C.; Muntau, H.

    1987-09-01

    The Institute for Technology and Hygiene of Food of Animal Origin is developing a practible system of monitoring the distribution of toxic substances in the environment, using the dairy cows as bioindicators. A pilot project has been established to solve basic problems as sampling strategy, sample preparation, analysis and data handling. In the preliminary stage of this study the new technique of SS-AAS turned out to be a useful tool. In order to test overall analytical reliability of the data obtained all analytical procedures applied for the different matrices are controlled by the use of reference material of similar matrix compositions. Results of studies on the distribution of admium and lead are reported; the representativity of small sample amounts of cortical tissue (50-60 mg and 1-2 mg dry mass) has additionally been investigated. Direct analysis of wet tissue aliquots (5-10 mg) was not feasible. A possible method of sample preparation of wet tissue is presented which yields reliable results within 10 min of operation time.

  12. Radioactive contamination monitoring device for off-gas in ventilation system

    International Nuclear Information System (INIS)

    Osaki, Masahiko; Watabe, Atsushi; Kaneko, Itaru; Kubokoya, Takashi.

    1990-01-01

    In a conventional method of detecting leakage for primary coolants, radioactive iodine in off-gases was detected while going up the off-gas system. As an event resulting in abnormality to radioactive rare gas level, leakage of water, leakage in cleanup system-recycling system, leakage in main steams and leakage from wastes processing system are considered. An off-gas system to be measured is selectively sampled by a sample changer in order to measure radioactive rare gases in the off-gases, and sample gases are introduced to detect radioactivity. Detection signals are received for analysis and quantitative determination, the result of the analysis is diagnosed and the presence or absence of abnormality in an object to be measured is determined. Subsequently, an abnormality alarm and the result of the analysis are outputted. Since the radioactive rare gases are chemically inactive, they are neither combined with other materials nor deposited to wall surfaces. Abnormality can be easily detected by always monitoring a composition pattern and a radioactivity level. (N.H.)

  13. Strategies and guidance for establishing an inclusive radiation monitoring in case of long term radioactive contamination: the SAGE project

    International Nuclear Information System (INIS)

    Lepicard, S.

    2004-01-01

    The evaluation of the rehabilitation strategies implemented in the CIS countries affected by the Chernobyl catastrophe pointed out the importance to involve the population in the day-to-day management of the radiological situation. The ETHOS experience in Belarus has revealed that to be effective and sustainable, this involvement must rely on the dissemination of a practical radiological protection culture within the population and especially within health professionals. As part of this culture, the implementation of an inclusive radiation monitoring system is a key element to allow the population and the local professionals to regain control on the day-to-day situation as far as the radiological risk is concerned. The SAGE Project, funded by the European Commission, started in October 2002 and will last 30 months. The objective is to develop strategies and guidance for disseminating such a system in Western Europe, in case of a long-term radiological contamination. The partnership of the Project is composed of 5 teams of researchers from the following institutions: BB RIR (the Brest Branch of the Research Institute of Radiology - Belarus), BELRAD (the Institute of Radiation Safety - Belarus), CEPN (France), GSF (Germany) and NRPB (United Kingdom). The key output of the project will be a handbook giving a comprehensive guidance on how to tackle the questionings and problems faced by the population. The proposed strategies and guidance are developed by national 'stakeholders panels' involving representatives from the society (medical doctors, radiation protection experts, teachers, representatives from NGOs,...) both in the contaminated territories of Belarus and in the above mentioned three Member States. This paper will present the methodology of work with the stakeholder panels and the major findings so far, especially the elements they have pointed out to be of a particular importance. The preliminary contents of the handbook will be presented as well. (author)

  14. Application of diagnosis and monitoring area contaminated by petroleum derivatives; Aplicacao da tecnica de caminhamento eletrico em area contaminada por derivados de petroleo

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Cesar Augusto [Pos-graduacao em Geociencias em Meio Ambiente, IGCE - UNESP, Rio Claro, SP (Brazil)], E-mail: cesargeologia@yahoo.com.br; Dourado, Joao Carlos; Braga, Antonio Celso de Oliveira [Dept. de Geologia Aplicada, IGCE - UNESP, Rio Claro, SP (Brazil)], E-mails: jdourado@rc.unesp.br, acobraga@rc.unesp.br

    2006-07-15

    Geophysical methods are useful technic of geological investigation, thoroughly employed to diagnosis and monitoring contaminated areas, in conjunction with direct techniques of investigation such as chemical analyses. Among these, electric resistivity is more usually used in studies of contaminants in soil and groundwater, due to the high contrast of electric properties between the soil and the pollutant types frequently found, essentially constituted of composed organic and inorganic. Geophysical studies in impacted areas by petroleum products may be describe by anomalies of both low resistivity and high resistivities, confirmed as contaminant by chemical analyses. This apparent contradiction can reflect processes of degradation of the contaminants, directly associated with its residence time in the soil, through the generation of by-products that change the physical properties of the soil and groundwater, principally for the mineral dissolution by action of organic acids and by formation of minerals of oxides and hydroxides minerals. Natural attenuation defines a series of physical, chemical and biological processes that allow the degradation, dispersion and dilution of contaminants in a natural form, in other words, free from human intervention. This paper presents the application of electrical profiling technique in a contaminated industrial area for benzene, toluene, xylene, 1,2 dichloroethene and inorganic salts and it discusses the physical alterations of the contaminated soil through the obtained results, under the optics of the Natural Attenuation in course in the area of study. (author)

  15. Evaluation of targeted and untargeted effects-based monitoring tools to assess impacts of contaminants of emerging concern on fish in the South Platte River, CO.

    Science.gov (United States)

    Ekman, Drew R; Keteles, Kristen; Beihoffer, Jon; Cavallin, Jenna E; Dahlin, Kenneth; Davis, John M; Jastrow, Aaron; Lazorchak, James M; Mills, Marc A; Murphy, Mark; Nguyen, David; Vajda, Alan M; Villeneuve, Daniel L; Winkelman, Dana L; Collette, Timothy W

    2018-08-01

    Rivers in the arid Western United States face increasing influences from anthropogenic contaminants due to population growth, urbanization, and drought. To better understand and more effectively track the impacts of these contaminants, biologically-based monitoring tools are increasingly being used to complement routine chemical monitoring. This study was initiated to assess the ability of both targeted and untargeted biologically-based monitoring tools to discriminate impacts of two adjacent wastewater treatment plants (WWTPs) on Colorado's South Platte River. A cell-based estrogen assay (in vitro, targeted) determined that water samples collected downstream of the larger of the two WWTPs displayed considerable estrogenic activity in its two separate effluent streams. Hepatic vitellogenin mRNA expression (in vivo, targeted) and NMR-based metabolomic analyses (in vivo, untargeted) from caged male fathead minnows also suggested estrogenic activity downstream of the larger WWTP, but detected significant differences in responses from its two effluent streams. The metabolomic results suggested that these differences were associated with oxidative stress levels. Finally, partial least squares regression was used to explore linkages between the metabolomics responses and the chemical contaminants that were detected at the sites. This analysis, along with univariate statistical approaches, identified significant covariance between the biological endpoints and estrone concentrations, suggesting the importance of this contaminant and recommending increased focus on its presence in the environment. These results underscore the benefits of a combined targeted and untargeted biologically-based monitoring strategy when used alongside contaminant monitoring to more effectively assess ecological impacts of exposures to complex mixtures in surface waters. Published by Elsevier Ltd.

  16. Economics of place-based monitoring under the safe drinking water act, part I: spatial and temporal patterns of contaminants, and design of screening strategies.

    Science.gov (United States)

    Brands, Edwin; Rajagopal, R

    2008-08-01

    The goals of environmental legislation and associated regulations are to protect public health, natural resources, and ecosystems. In this context, monitoring programs should provide timely and relevant information so that the regulatory community can implement legislation in a cost-effective and efficient manner. The Safe Drinking Water Act (SDWA) of 1974 attempts to ensure that public water systems (PWSs) supply safe water to its consumers. As is the case with many other federal environmental statutes, SDWA monitoring has been implemented in relatively uniform fashion across the USA. In this three part series, spatial and temporal patterns in water quality data are utilized to develop, compare, and evaluate the economic performance of alternative place-based monitoring approaches to current monitoring practice. Under the Safe Drinking Water Act (SDWA), a common list of over 90 contaminants is analyzed nationwide using EPA-authorized laboratory procedures. National and state-level summaries of SDWA data have shown that not all contaminants occur in all places at all times. This hypothesis is confirmed and extended by showing that only a few (less than seven) contaminants are of concern in any one of 19 Iowa surface water systems studied. These systems collectively serve about 350,000 people and their sizes vary between 1,200 and 120,000. The distributions of contaminants found in these systems are positively skewed, with many non-detect measurements. A screening strategy to identify such contaminants in individual systems is presented. These findings have significant implications not only for the design of alternative monitoring programs, but also in multi-billion-dollar decisions that influence the course of future drinking water infrastructure, repair, and maintenance investments.

  17. Satellite infrared imagery for thermal plume contamination monitoring in coastal ecosystem of Cernavoda NPP

    Science.gov (United States)

    Zoran, M. A.; Zoran, Liviu Florin V.; Dida, Adrian I.

    2017-10-01

    Satellite remote sensing is an important tool for spatio-temporal analysis and surveillance of NPP environment, thermal heat waste of waters being a major concern in many coastal ecosystems involving nuclear power plants. As a test case the adopted methodology was applied for 700x2 MW Cernavoda nuclear power plant (NPP) located in the South-Eastern part of Romania, which discharges warm water affecting coastal ecology. The thermal plume signatures in the NPP hydrological system have been investigated based on TIR (Thermal Infrared) spectral bands of NOAA AVHRR, Landsat TM/ETM+/OLI, and MODIS Terra/Aqua time series satellite data during 1990-2016 period. If NOAA AVHRR data proved the general pattern and extension of the thermal plume signature in Danube river and Black Sea coastal areas, Landsat TM/ETM and MODIS data used for WST (Water Surface Temperature) change detection, mapping and monitoring provided enhanced information about the plume shape, dimension and direction of dispersion in these waters. Thermal discharge from two nuclear reactors cooling is dissipated as waste heat in Danube-Black -Sea Channel and Danube River. From time-series analysis of satellite data during period 1990-2016 was found that during the winter season thermal plume was localized to an area of a few km of NPP, and the mean temperature difference between the plume and non-plume areas was about 1.7 oC. During summer and fall, derived mean temperature difference between the plume and non-plume areas was of about 1.3°C and thermal plume area was extended up to 5- 10 km far along Danube Black Sea Channel.

  18. Organohalogen diffuse contamination in Firenze and Prato groundwater bodies. investigative monitoring and definition of background values

    Directory of Open Access Journals (Sweden)

    Stefano Menichetti

    2017-03-01

    Full Text Available The experience of the Environmental Protection Agency of Tuscany in the determination of background values start from 2009 with various substances such as metals, non-metals and inorganic, dioxins and various matrices such as soil, groundwater, inland surface waters and coastal marine sediments. The methodologies supplied in literature have been interpreted and integrated to meet the requirements of current legislation and needs for remediation, diffuse pollution and excavated earth in specific areas. The method for diffuse pollution described here focuses on the use of statistical and geostatistical tools and what we present in this paper are some early results of interest obtained from two case studies in the Florence and in the Prato area. The study has been carried out on concentrations of tetrachlorethylene in the two groundwater bodies by identifying a number of frequency classes in the distribution. Each class has been hypothesized as corresponding to a distinct process. The occurrence both in space and time of the classes has been analysed and discussed critically concluding for a background value that has been found similar between the two zones. The investigation conducted on two monitoring stations representing hot-spots, with values in excess on background value has enabled to map spatial distribution of concentrations and to separate plumes from diffuse pollution area. The two areas show some peculiarities: Florence area shows advanced dehalogenation and a clear spatial continuity, whereas in Prato area it is limited with poor spatial continuity suggesting a spreading with vertical motions from still active primary or secondary sources. Observing how the methodological structure would require, to be fully predictive, a greater number of samples, however, the present work want to constitute a first contribution for management of areas subject to diffuse pollution.

  19. Monitoring the aftermath of Flint drinking water contamination crisis: Another case of sampling bias?

    Science.gov (United States)

    Goovaerts, Pierre

    2017-07-15

    The delay in reporting high levels of lead in Flint drinking water, following the city's switch to the Flint River as its water supply, was partially caused by the biased selection of sampling sites away from the lead pipe network. Since Flint returned to its pre-crisis source of drinking water, the State has been monitoring water lead levels (WLL) at selected "sentinel" sites. In a first phase that lasted two months, 739 residence