WorldWideScience

Sample records for personal protective devices

  1. Privacy Protection for Personal Health Device Communication and Healthcare Building Applications

    Directory of Open Access Journals (Sweden)

    Soon Seok Kim

    2014-01-01

    Full Text Available This paper proposes a new method for protecting patient privacy when communicating with a gateway which collects bioinformation through using personal health devices, a type of biosensor for telemedicine, at home and in other buildings. As the suggested method is designed to conform with ISO/IEEE 11073-20601, which is the international standard, interoperability with various health devices was considered. We believe it will be a highly valuable resource for dealing with basic data because it suggests an additional standard for security with the Continua Health Alliance or related international groups in the future.

  2. Information booklet on personal protective equipment: eye and face protection

    International Nuclear Information System (INIS)

    1992-01-01

    In all work places where hazards of various kinds are present and the same cannot be totally controlled by engineering methods, suitable personal protective equipment (PPE) shall be used. There are several types of eye and face protection devices available in the market and it is important that employees use the proper type for the particular job. The main classes of eye and face protection devices required for the industrial operations are as follows: (a) eye protection devices which includes: (i) safety goggles (ii) safety spectacles (iii) safety clipons and eye and face protection devices which are (i) eye shield, (ii) face shield, (iii) wire mesh screen guard. Guide lines for selecting appropriate ear and face protection equipment for nuclear installations are given. (M.K.V.). 4 annexures, 1 appendix

  3. Gate protective device for SOS array

    Science.gov (United States)

    Meyer, J. E., Jr.; Scott, J. H.

    1972-01-01

    Protective gate device consisting of alternating heavily doped n(+) and p(+) diffusions eliminates breakdown voltages in silicon oxide on sapphire arrays caused by electrostatic discharge from person or equipment. Diffusions are easily produced during normal double epitaxial processing. Devices with nine layers had 27-volt breakdown.

  4. Study of the Effective Parameters on the Making Use of Protective Devices

    Directory of Open Access Journals (Sweden)

    Y Tabaraie

    2012-05-01

    Full Text Available

    Background and objectives

    Noise threats health of many groups of industrial workers and causes hearing loss. Use of personal protective device is the best control method to protect against hazardous conditions. Hence, this investigation was carried out to determine situation of using of protective devices and effective parameters on it, in Qom province workers community in 2006.

     

    Methods

    This research is descriptive-sectional study. Sample volume was designed 378 persons working in factories in Qom. First of all, list of Qom factories with noise pollution problems, were collected and 30 important factories among them were selected randomly. In the second stage, 378 persons were selected randomly from workers. The interest information was obtained by questionnaire and collected data were analyzed by SPSS software.

     

    Results

    The obtained results showed that, 83.6% of workers have been using ear protective devices. 296 of them, which were using ear protective devices, had an occupational hygienist in their workplaces. This research also showed that, 109 workers that used ear protective devices, had moderate knowledge level. Moreover, 82.5% of trained workers have used ear protective devices. The statistical analysis of the results showed that there were no significant relationship between use of ear protective devices and existence of occupational hygienist in workplace, knowledge and age of workers, worker’s antecedent, physical health of workers and kind of ear protective devices (p> 0.05. 

     

    Conclusion

    These results showed that among all considered parameters; only four parameters were effective in using ear protective devices; education of workers before employment, head workman and employer’s knowledge level, factories facilitation and kind of ear protective devices.

     

  5. Implications of the Protection of Personal Information (POPI)

    African Journals Online (AJOL)

    The main purpose of the POPI act is to protect the processing of personal information ... a smartphone, iPad or personal computer), digital storage devices. (iCloud, Dropbox ... (vi) Reasonable security regarding the safeguarding, integrity and.

  6. Protective device for organs exposed to medical X-radiation

    International Nuclear Information System (INIS)

    Zimmer, K.

    1978-01-01

    The protective device for male or female gonads consists of a protective screen made of hard lead coated with silicon caoutchouc, a flexible supporting arm, and a base plate on which the supporting arm for the protective screen is monted. The protective screen has got the shape of a dish resp. a pear-shaped contour for male resp. female persons. The base may be arranged on a Bucky table between the legs of the person to be examined by means of suction cups. (DG) [de

  7. Protection device for a thermonuclear device

    International Nuclear Information System (INIS)

    Kawashima, Shuichi.

    1986-01-01

    Purpose: To exactly detect the void coefficients of coolants even under high magnetic fields thereby detect the overheat of a thermonuclear device at an early stage. Constitution: The protecting device of this invention comprises a laser beam generation device, a laser beam detection device and an accident detection device. The laser generation device always generates laser beams, which are permeated through coolants and detected by the laser beam detection device, the optical amount of which is transmitted to the accident detection device. The accident detection device judges the excess or insufficiency of the detected optical amount with respect to the optical amount of the laser beams under the stationary state as a reference and issues an accident signal. Since only the optical cables that do not undergo the effect of the magnetic fields are exposed to high magnetic fields in the protection device of this invention, a high reliability can be maintained. (Kamimura, M.)

  8. Evaluation of commercial products for personal protection against mosquitoes.

    Science.gov (United States)

    Revay, Edita E; Junnila, Amy; Xue, Rui-De; Kline, Daniel L; Bernier, Ulrich R; Kravchenko, Vasiliy D; Qualls, Whitney A; Ghattas, Nina; Müller, Günter C

    2013-02-01

    Human landing catch studies were conducted in a semi-field setting to determine the efficacy of seven commercial products used for personal protection against mosquitoes. Experiments were conducted in two empty, insecticide free, mesh-enclosed greenhouses, in Israel, with either 1500 Aedes albopictus or 1500 Culex pipiens released on consecutive study nights. The products tested in this study were the OFF!(®) Clip-On™ Mosquito Repellent (Metofluthrin 31.2%) and the Terminix(®) ALLCLEAR(®) Sidekick Mosquito Repeller (Cinnamon oil 10.5%; Eugenol 13%; Geranium oil 21%; Peppermint 5.3%; Lemongrass oil 2.6%), which are personal diffusers; Super Band™ Wristband (22% Citronella oil) and the PIC(®) Citronella Plus Wristband (Geraniol 15%; Lemongrass oil 5%, Citronella oil 1%); the Sonic Insect Repeller Keychain; the Mosquito Guard Patch (Oil of Lemon Eucalyptus 80mg), an adhesive-backed sticker for use on textiles; and the Mosquito Patch (vitamin B1 300mg), a transdermal patch. It was determined that the sticker, transdermal patch, wristbands and sonic device did not provide significant protection to volunteers compared with the mosquito attack rate on control volunteers who were not wearing a repellent device. The personal diffusers: - OFF!(®) Clip-On™ and Terminix(®) ALLCLEAR(®) Sidekick - provided superior protection compared with all other devices in this study. These diffusers reduced biting on the arms of volunteers by 96.28% and 95.26% respectively, for Ae. albopictus, and by 94.94% and 92.15% respectively, for Cx. pipiens. In a second trial conducted to compare these devices directly, biting was reduced by the OFF!(®) Clip-On™ and the Terminix(®) ALLCLEAR(®) by 87.55% and 92.83%, respectively, for Ae. albopictus, and by 97.22% and 94.14%, respectively, for Cx. pipiens. There was no significant difference between the performances of the two diffusers for each species. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Personal protective equipment

    International Nuclear Information System (INIS)

    2004-01-01

    This Practical Radiation Technical Manual is one of a series that has been designed to provide guidance on radiological protection for employers, radiation protection officers, managers and other technically competent persons who have responsibility for ensuring the safety of employees working with ionizing radiation. The Manual may be used with the appropriate IAEA Practical Radiation Safety Manuals to provide training, instruction and information for all employees engaged in work with ionizing radiation. Personal protective equipment (PPE) includes clothing or other special equipment that is issued to individual workers to provide protection against actual or potential exposure to ionizing radiations. It is used to protect each worker against the prevailing risk of external or internal exposure in circumstances in which it is not reasonably practicable to provide complete protection by means of engineering controls or administrative methods. Adequate personal protection depends on PPE being correctly selected, fitted and maintained. Appropriate training for the users and arrangements to monitor usage are also necessary to ensure that PPE provides the intended degree of protection effectively. This Manual explains the principal types of PPE, including protective clothing and respiratory protective equipment (RPE). Examples of working procedures are also described to indicate how PPE should be used within a safe system of work. The Manual will be of most benefit if it forms part of a more comprehensive training programme or is supplemented by the advice of a qualified expert in radiation protection. Some of the RPE described in this Manual should be used under the guidance of a qualified expert

  10. Personal radiation protection in nuclear industry

    International Nuclear Information System (INIS)

    Gol'dshtejn, D.S.; Koshcheev, V.S.

    1983-01-01

    Specific peculiarities of organization of personal radiation protection at various nuclear industry enterprises when dealing with radioactive and other toxic substances are illuminated. Effect of heatin.g and cooling microclimate is discussed. Medical and technical requirements for personal protection means and tasks of personal protection in the field of nuclear industry are considered in short along with some peculiarities of application of different kinds of personal protection means and psychological aspects of personnel protection

  11. Metoda ispitivanja kompatibilnosti sredstava lične NHB zaštite / Method of testing compatibility of personal NBC protection devices

    Directory of Open Access Journals (Sweden)

    Dušan Rajić

    2009-07-01

    Full Text Available Na primeru izabranih sredstava lične NHB zaštite demonstrirana je primena metode procene kompatibilnosti, kao vrlo bitne taktičko-tehničke karakteristike za svako novouvedeno sredstvo naoružanja i vojne opreme (NVO u Vojsci Srbije. Utvrđeno je da zaštitno filtrirajuće odelo, zaštitni laki ogrtač i zaštitne rukavice ispunjavaju postavljene kriterijume kompatibilnosti. Opisana metoda provere kompatibilnosti može da se primenjuje i na druga sredstva NVO u fazama razvoja, proizvodnje i eksploatacije. / The selected personal NBC protection devices have served as an example for demonstrating the application of the compatibility evaluation method as a very important tactical-technical characteristic of each newly introduced item of weapon and military equipment in the Serbian army. It has been determined that a filtering protective suit, a light protective coat and protective gloves meet the required criteria of compatibility. The described method of testing compatibility can be also applied to other weapons and military equipment in stages of development, production and exploitation.

  12. Usefulness of the protection motivation theory in explaining hearing protection device use among male industrial workers.

    Science.gov (United States)

    Melamed, S; Rabinowitz, S; Feiner, M; Weisberg, E; Ribak, J

    1996-05-01

    The present study examined the usefulness of personal variables: noise annoyance, and components of the protection motivation theory (R. W. Rogers, 1983) along with social-organizational factors in explaining hearing protection device (HPD) use among Israeli manufacturing workers. Participants were 281 men exposed to harmful noise levels for which routine HPD use is required by regulation. In practice, 3 HPD user groups were identified: nonusers (n = 38), occasional users (n = 125), and regular users (n = 118). HPD use was objectively verified. HPD use was primarily related to the personal variables but not to management pressure, coworker pressure, or family support. The most powerful predictors of HPD use were perceived self-efficacy (for long-term HPD use), perceived susceptibility (to hearing loss), and noise annoyance, together explaining 48% of the outcome variance. These findings have implications for interventions aimed at motivating workers to use HPDs regularly.

  13. Safety of persons protected by the Government Protection Bureau

    Directory of Open Access Journals (Sweden)

    Wojciech Lis

    2015-12-01

    Full Text Available The state is the organizational structure, which unites the whole nation by providing optimal conditions for the functioning and development. One of the conditions for the basic functions of the state is efficient administration headed by a person with the role of management. They not only hold the highest position, but also represent the authority of the state. For this reason, they need special protection. Each attack undermines the authority of the administration and trust in the state institutions. For the protection of persons performing managerial functions in the state corresponds to the Government Protection Bureau that providing them protection at the same time protect the state.

  14. Increasing the Usage of Personal Protective Equipments in Constructing Subway Stations: An Application of Social Marketing Model

    Directory of Open Access Journals (Sweden)

    M Shams

    2013-10-01

    Full Text Available Abstract Background & aim: Although the relationship between the use of personal protective equipment and the reduction of workplace injuries is well-known the use of these devices during operation by the staff is not so desirable. This study was based on a model of social marketing interventions to increase the use of safety devices and personal protection on the subway-station staff. Methods: The present quasi-experimental study was based on the results of a formative research consisted of a qualitative (exploring employees’ views through focus group discussions and a quantitative study (measuring attitudes and behaviors by questionnaire and checklist. Based on the formative research findings, a free package includes a helmet with a label containing the message, an anti-cut safety gloves, a dust mask, and an educational pamphlet were delivered to intervention group. After four weeks, the check list of observational behaviors in two constructing stations was completed and the results were compared with before intervention. The data were analyzed by paired t-test, t-test and logistic regression. Results: Three common behaviors were observed among staff not using caps, masks and gloves. The odds ratio for helmet and mask usage in the intervention group was more than other groups. After the intervention, the use of safety helmets and masks significantly increased (p < 0.05. The odds ratio for the use of helmets and masks after intervention in the intervention group was significantly higher than other groups (p < 0.05. Conclusion: The experimental basis of the safety devices and personal protection needs and demands of the audience, material and immaterial costs of the equipment, supplies, and promoting their use in the right place, can encourage the staff to continuously use the safety devices at workplace. Key Words: Workplace, Injuries, Personal Protective Equipment, Social Marketing

  15. Automatic coordination of protection devices in distribution system

    International Nuclear Information System (INIS)

    Comassetto, L.; Bernardon, D.P.; Canha, L.N.; Abaide, A.R.

    2008-01-01

    Among the several components of distribution systems, protection devices present a fundamental importance, since they aim at keeping the physical integrity not only of the system equipment, but also of the electricians' team and the population in general. The existing tools today in the market that carry out the making of protection studies basically draw curves, and need direct user's interference for the protection devices adjustment and coordination analyses of selectivity, being susceptible to the user's mistakes and not always considering the best technical and economical application. In Brazil, the correct application of the protection devices demand a high amount of time, being extremely laborious due to the great number of devices (around 200 devices), besides the very dynamic behaviour of distribution networks and the need for constant system expansion. This article presents a computational tool developed with the objective of automatically determining the adjustments of all protection devices in the distribution networks to obtain the best technical application, optimizing its performance and making easier protection studies. (author)

  16. Personal Protective Equipment

    National Research Council Canada - National Science Library

    1998-01-01

    ... of personal protective equipment A safety program for new employees is a necessary part of any orientation program An on-going safety program should be used to motivate employees to continue to use...

  17. Protection of personality rights in civil law

    Directory of Open Access Journals (Sweden)

    Simonović Ivana

    2014-01-01

    Full Text Available Personality rights have long been described as the youngest member of the civil law family of absolute subjective (individual civil rights. By establishing these rights, an individual is guaranteed full and direct legal authority and control over one's personal assets, which include the most important human values such as: life, integrity, dignity and privacy. The ultimate importance of these personal assets is supported by appropriate legal protection of personality rights, which have been guaranteed in numerous provisions of constitutional law, civil law, criminal law and administrative law. The legal protection of personality rights stems from the understanding that a human being cannot be reduced to a biological entity; being part of the community, man is also a social being. Taking into account constant interactions and mutual relations between members of the society, man should be guaranteed certain rights. It primarily implies the guaranteed right to inviolability of one's personality, which is the basis for generating other personality rights. These rights are inherent, inalienable and absolute in terms of their effects; as such, they provide protection from the interference of the state and any third party. Focusing on the rules of civil law, the authors have explored the potentials and the scope of legal protection of personality rights provided by awarding a civil sanction. Although civil sanction is basically monetary sanction, it is deemed to be quite appropriate for the protection of personal (non-patrimonial assets.

  18. Personal information search on mobile devices

    OpenAIRE

    Akbas, Mehmet.

    2007-01-01

    Today's mobile devices, especially mobile phones, are comparable in computing capability and storage to the desktop computers of a few years ago. The volume and diversity of the information kept on mobile devices has continually increased and users have taken advantage of this. Since information is being stored on multiple devices, searching for and retrieving the desired information has become an important function. This thesis focuses on search with regard to Personal Information Manag...

  19. Consumers' Use of Personal Electronic Devices in the Kitchen.

    Science.gov (United States)

    Lando, Amy M; Bazaco, Michael C; Chen, Yi

    2018-02-23

    Smartphones, tablets, and other personal electronic devices have become ubiquitous in Americans' daily lives. These devices are used by people throughout the day, including while preparing food. For example, a device may be used to look at recipes and therefore be touched multiple times during food preparation. Previous research has indicated that cell phones can harbor bacteria, including opportunistic human pathogens such as Staphylococcus and Klebsiella spp. This investigation was conducted with data from the 2016 Food Safety Survey (FSS) and from subsequent focus groups to determine the frequency with which consumers use personal electronic devices in the kitchen while preparing food, the types of devices used, and hand washing behaviors after handling these devices. The 2016 FSS is the seventh wave of a repeated cross-sectional survey conducted by the U.S. Food and Drug Administration in collaboration with the U.S. Department of Agriculture. The goal of the FSS is to evaluate U.S. adult consumer attitudes, behaviors, and knowledge about food safety. The FSS included 4,169 adults that were contacted using a dual-frame (land line and cell phone interviews) random-digit-dial sampling process. The personal electronics module was the first of three food safety topics discussed by each of eight consumer focus groups, which were convened in four U.S. cities in fall 2016. Results from the 2016 FSS revealed that of those individuals who use personal electronic devices while cooking, only about one third reported washing hands after touching the device and before continuing cooking. This proportion is significantly lower than that for self-reported hand washing behaviors after touching risky food products such as raw eggs, meat, chicken, or fish. Results from the focus groups highlight the varied usage of these devices during food preparation and the related strategies consumers are using to incorporate personal electric devices into their cooking routines.

  20. Protective device for battery to protect against heavy discharge

    Energy Technology Data Exchange (ETDEWEB)

    1979-02-08

    The protective device according to the invention switches the equipment being supplied from the battery at a pre-determined discharge voltage by means of a switching device controlled by monitoring equipment. A semi-conductor element is used as the switching device. The current taken from the battery flows through the semi-conductor element to the equipment and to the monitoring device. When the discharge voltage is reached the semi-conductor element blocks. The semi-conductor switch can consist of transistors. The invention is explained by means of drawings and examples.

  1. Google and personal data protection

    NARCIS (Netherlands)

    van der Sloot, B.; Zuiderveen Borgesius, F.; Lopez-Tarruella, A.

    2012-01-01

    This chapter discusses the interplay between the European personal data protection regime and two specific Google services, Interest-Based Advertising and Google Street View. The chapter assesses first the applicability of the Data Protection Directive, then jurisdictional issues, the principles

  2. Eighth meeting of the radiation protection-skilled persons - Conference proceedings

    International Nuclear Information System (INIS)

    Juhel, Thierry; Lahaye, Thierry; Rousse, Carole; Perrin, Marie-Line; Billarand, Yann; Scanff, Pascale; Celier, David; El Jammal, Marie-Helene; Jacob, Sophie; Vecchiola, Sophie; Bulla, Giuseppina; Guillalmon, Christophe; Mechin, Guillaume; Guersen, Joel; Blaise, Philipp; Ammerich, Marc; Bordy, Jean-Marc; Sevestre, Bernard; Massiot, Philippe; Michel, Xavier; Raffoux, Yann; Kernisant, Billy; Lefaure, Christian; Balduyck, Sebastien; Wassilieff, Serge; Ouabdelkader, Said; Lecu, Alexis; Roy, Catherine; Pigree, Gilbert; Barbey, Pierre; Bergeron, Christophe; Schieber, Caroline

    2012-12-01

    This eighth meeting of the radiation protection skilled persons celebrated the 15. anniversary of this type of meetings. It is the occasion for radiation protection specialists to share information and their experience on various topics, in particular the recent evolutions of the regulation. This document gathers the available presentations given during this conference: 1 - Opening talk (T. Juhel); 2 - Regulatory evolutions in the domain of protection of workers exposed to ionising radiations (T. Lahaye); 3 - Evolution of the regulatory documents on the basis of the French public health law (C. Rousse); 4 - Relations between IRSN and Companies - regulatory obligations from the perspective of the radiation protection-skilled person (Y. Billarand); 5 - IRSN's follow up of workers' exposure (P. Scanff); 6 - Contribution of a 18 F preparation and injection system to the radiation protection of workers (D. Celier); 7 - Workplace analysis in interventional radiology (G. Bulla, C. Guillalmon); 8 - Interest of Workplace analyses in risk information (G. Mechin); 9 - Running of a joint operators/contractors club of radiation protection skilled persons at the scale of a CEA centre (P. Blaise); 10 - Radiological exposure of the maintenance personnel of aerial monitoring radars (X. Michel); 11 - The IRSN barometer (M.H. El Jammal); 12 - An original network of professional radiation protection: the GoogleGroup for dental radiation protection-skilled persons (Y. Raffoux); 13 - Cirkus radiation protection association - a portal for a practical and operational radiation protection (B. Kernisant); 14 - Situation of networks - what do we do in a network? What is the role of the national coordination? (S. Balduyck, C. Lefaure); 15 - Update on the situation at Fukushima (M. Ammerich); 15 - Radio-induced cataracts: why lowering the eye lens legal limit? (S. Wassilieff); 16 - O'CLOC study - Radio-induced cataracts among interventional Cardiologists (S. Jacob); 17 - Photon dosimetry of

  3. Safeguards of basic protection devices, high-protection devices, full-protection devices and school X-ray devices. Guideline for manufacturer and evaluating experts, rev. 1.0; Sicherheitsvorrichtungen von Basisschutzgeraeten, Hochschutzgeraeten, Vollschutzgeraeten und Schulroentgeneinrichtungen. Anforderungen fuer die Bauartpruefung nach der Roentgenverordnung. Leitfaden fuer Hersteller und Gutachter Rev. 1.0

    Energy Technology Data Exchange (ETDEWEB)

    Dombrowski, Harald; Grottker, Ulrich; Pullner, Bjoern; Roettger, Annette; Zwiener, Roland

    2017-07-15

    This report describes the PTB requirements for engineered safeguards of basic-protection devices, high-protection devices, full-protection devices and school X-ray devices within the framework of type tests according to the German X-ray Ordinance. It contains detailed requirements for the hard- and software to ensure the required safety level. Especially manufacturers and evaluators of such X-ray tube assemblies are addressed.

  4. 22 CFR 212.22 - Protection of personal privacy.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Protection of personal privacy. 212.22 Section... Information for Public Inspection and Copying § 212.22 Protection of personal privacy. To the extent required to prevent a clearly unwarranted invasion of personal privacy, USAID may delete identifying details...

  5. Biometric authentication for a mobile personal device

    NARCIS (Netherlands)

    Tao, Q.; Veldhuis, Raymond N.J.

    2006-01-01

    Secure access is prerequisite for a mobile personal device (MPD) in a personal network (PN). An authentication method using biometrics, specifically face, is proposed in this paper. A fast face detection and registration method based on a Viola-Jones detector is implemented, and a

  6. Biometric Authentication System on Mobile Personal Devices

    NARCIS (Netherlands)

    Tao, Q.; Veldhuis, Raymond N.J.

    We propose a secure, robust, and low-cost biometric authentication system on the mobile personal device for the personal network. The system consists of the following five key modules: 1) face detection; 2) face registration; 3) illumination normalization; 4) face verification; and 5) information

  7. The use of hearing protection devices with approach risk perception of noise induced hearing loss in several manufacturing industry

    Directory of Open Access Journals (Sweden)

    Behzad Fouladi Deahghi

    2015-06-01

    Full Text Available Background & Objective : Noise is a widespread physical agent and although is a most risk factors in workplaces that workers of health to exposed. Thus, different actions is done for reduce exposure to it in work places, which one of them is use of hearing protection devices. The use of hearing protection devices with approach risk perception of noise induced hearing loss in several manufacturing industry Method: This study was Cross-sectional study and done in five industrial unit with a sound pressure level more of 85 dB-A with the participation of 340 workers. To collect data , individual risk perception and self-investigator questionnaires were used. After collecting data, statistical analysis including Cronbach's alpha and regression were used to analyze the data. Results : Range use of hearing protection devices during shifts work by workers, respectively equal to: 50.4% sometimes, 31.58% never and 18.2% at all times. Also, results indicate significant differences between individual differences and hearing protection devices. Conclusion : Results of this study showed that individual risk perception as an important factor, can do a significant role in predicting the behavior of personals in the use of hearing protection devices, which should be considered in any design and implementation of hearing protection program.

  8. Insertion Loss of Personal Protective Clothing

    International Nuclear Information System (INIS)

    Shull, D.J.

    1999-01-01

    The use of personal protective clothing that covers the head is a common practice in many industries. Such personal protective clothing will impact the sound pressure level and the frequency content of sounds to which the wearer will be exposed. The use of such clothing, then, may impact speech and alarm audibility. A measure of the impact of such clothing is its insertion loss. Insertion loss measurements were performed on four types of personal protective clothing in use by Westinghouse Savannah River Company personnel which utilize cloth and plastic hood configurations to protect the head. All clothing configurations tested at least partially cover the ears. The measurements revealed that insertion loss of the items tested was notable at frequencies above 1000 Hz only and was a function of material stiffness and acoustic flanking paths to the ear. Further, an estimate of the clothing's noise reduction rating reveals poor performance in that regard, even though the insertion loss of the test articles was significant at frequencies at and above 1000 Hz.'

  9. The Use of DLP-systems for the Protection of Personal Data

    Directory of Open Access Journals (Sweden)

    I. S. Boridko

    2012-12-01

    Full Text Available The issues of the principal possibility of the application of DLP-systems (Data Leak Prevention System for the protection of personal data are considered. Approaches of Russian company SecurIT for the prevention of leakage of information through the connected devices and network channels (Zlock system and Zgate system are analyzed. Advantages of Zgate system are revealed, which allows to increase the efficiency of detection of confidential data with the average 60—70 % for existing DLP-systems up to 95 % of the Zgate.

  10. Fingerprinting Mobile Devices Using Personalized Configurations

    Directory of Open Access Journals (Sweden)

    Kurtz Andreas

    2016-01-01

    Full Text Available Recently, Apple removed access to various device hardware identifiers that were frequently misused by iOS third-party apps to track users. We are, therefore, now studying the extent to which users of smartphones can still be uniquely identified simply through their personalized device configurations. Using Apple’s iOS as an example, we show how a device fingerprint can be computed using 29 different configuration features. These features can be queried from arbitrary thirdparty apps via the official SDK. Experimental evaluations based on almost 13,000 fingerprints from approximately 8,000 different real-world devices show that (1 all fingerprints are unique and distinguishable; and (2 utilizing a supervised learning approach allows returning users or their devices to be recognized with a total accuracy of 97% over time

  11. An application of residual current protective device at electrical installation

    International Nuclear Information System (INIS)

    Firman Silitonga

    2008-01-01

    In an electrical installation, a protection for overload and short circuit are always to be installed. In addition to the installation, it is necessary to be installed a protection device for residual current because both the short circuit and the overload device protection will not work for the residual current. The quantity of the residual current must be defined first at any electrical installation to define an appropriate residual current protection so that not every residual current will break the circuit down. This paper will explain a method how to install a residual protection device for 3500 VA or more at TN and TT of earthing system. (author)

  12. Mining Personal Data Using Smartphones and Wearable Devices: A Survey

    Science.gov (United States)

    Rehman, Muhammad Habib ur; Liew, Chee Sun; Wah, Teh Ying; Shuja, Junaid; Daghighi, Babak

    2015-01-01

    The staggering growth in smartphone and wearable device use has led to a massive scale generation of personal (user-specific) data. To explore, analyze, and extract useful information and knowledge from the deluge of personal data, one has to leverage these devices as the data-mining platforms in ubiquitous, pervasive, and big data environments. This study presents the personal ecosystem where all computational resources, communication facilities, storage and knowledge management systems are available in user proximity. An extensive review on recent literature has been conducted and a detailed taxonomy is presented. The performance evaluation metrics and their empirical evidences are sorted out in this paper. Finally, we have highlighted some future research directions and potentially emerging application areas for personal data mining using smartphones and wearable devices. PMID:25688592

  13. Mining Personal Data Using Smartphones and Wearable Devices: A Survey

    Directory of Open Access Journals (Sweden)

    Muhammad Habib ur Rehman

    2015-02-01

    Full Text Available The staggering growth in smartphone and wearable device use has led to a massive scale generation of personal (user-specific data. To explore, analyze, and extract useful information and knowledge from the deluge of personal data, one has to leverage these devices as the data-mining platforms in ubiquitous, pervasive, and big data environments. This study presents the personal ecosystem where all computational resources, communication facilities, storage and knowledge management systems are available in user proximity. An extensive review on recent literature has been conducted and a detailed taxonomy is presented. The performance evaluation metrics and their empirical evidences are sorted out in this paper. Finally, we have highlighted some future research directions and potentially emerging application areas for personal data mining using smartphones and wearable devices.

  14. A Cognitive Style Perspective to Handheld Devices: Customization vs. Personalization

    Science.gov (United States)

    Hsieh, Chen-Wei; Chen, Sherry Y.

    2016-01-01

    Handheld devices are widely applied to support open and distributed learning, where students are diverse. On the other hand, customization and personalization can be applied to accommodate students' diversities. However, paucity of research compares the effects of customization and personalization in the context of handheld devices. To this end, a…

  15. Systematic approach in protection and ergonomics testing personal protective equipment

    NARCIS (Netherlands)

    Hartog. E.A. den

    2009-01-01

    In the area of personal protection against chemical and biological (CB) agents there is a strong focus on testing the materials against the relevant threats. The testing programs in this area are elaborate and are aimed to guarantee that the material protects according to specifications. This

  16. Device Data Protection in Mobile Healthcare Applications

    Science.gov (United States)

    Weerasinghe, Dasun; Rajarajan, Muttukrishnan; Rakocevic, Veselin

    The rapid growth in mobile technology makes the delivery of healthcare data and services on mobile phones a reality. However, the healthcare data is very sensitive and has to be protected against unauthorized access. While most of the development work on security of mobile healthcare today focuses on the data encryption and secure authentication in remote servers, protection of data on the mobile device itself has gained very little attention. This paper analyses the requirements and the architecture for a secure mobile capsule, specially designed to protect the data that is already on the device. The capsule is a downloadable software agent with additional functionalities to enable secure external communication with healthcare service providers, network operators and other relevant communication parties.

  17. Attenuation of earmuffs used simultaneously with respiratory protective devices

    Directory of Open Access Journals (Sweden)

    Emil Kozłowski

    2017-06-01

    Full Text Available Background: In the work environment, apart from the noise, employees may be exposed to other harmful factors. Therefore, they wear hearing protectors and other personal protective equipment. The aim of the study was to determine whether simultaneous use of earmuffs and respiratory protective devices affects the attenuation of earmuffs. Material and Methods: The study was conducted in laboratory conditions using the subjective REAT (Real Ear Attenuation at Threshold and objective MIRE (Microphone in Real Ear methods. The REAT method was used to measure sound attenuation of earmuffs, while MIRE was used to determine changes in attenuation of earmuffs due to the use of other personal protective equipment. Results: The study showed reduction in attenuation of earmuffs due to the use of a full face mask up to 20 dB. Using a full face mask causes that attenuation of earmuffs in the low frequency range is close to zero. Reduction in attenuation due to the use of half masks for complete with particle filters (half masks is 3–15 dB. Simultaneous use of earmuffs and filtering half masks makes small changes in attenuation not exceeding 3 dB. Conclusions: The study showed that full face masks give the greatest reduction in attenuation of earmuffs. On the other hand, the least reduction is observed in the case of filtering half masks. There is a significant difference between the reduction in attenuation of earmuffs worn with half masks for complete with particle filters because they may be equipped with different kind of the head strap. Med Pr 2017;68(3:349–361

  18. Second meeting of competent persons in radiation protection

    International Nuclear Information System (INIS)

    2000-01-01

    This conference treats the subjects interesting the competent persons in radiation protection. It is divided in four sessions. The first one concerns the regulatory bases for the action of competent persons and includes three articles, the second one is about the operational dosimetry and includes six articles, the third session is devoted to the sources and waste management and represents two texts, the last and fourth session concerns the competent person in radiation protection and gives evidence. (N.C.)

  19. Information booklet on personal protective equipment: arm and hand protection

    International Nuclear Information System (INIS)

    1992-01-01

    Fire, heat, cold, electro-magnetic and ionising radiation, electricity, chemicals, impacts, cuts, abrasion, etc. are the common hazards for arms and hands at work. The gloves chosen for protection of the arm and hand should cover those parts adequately and the material of the gloves should be capable of offering protection against the specific hazard involved. Criteria for choosing arm and hand protection equipment will be based on their shape and part of the arm and hand protected. Guide lines for choosing such personal protection equipment for nuclear facilities are given. (M.K.V.). 3 annexures, 1 appendix

  20. Neutron protection material and neutron protection devices made of such material

    International Nuclear Information System (INIS)

    Ries, W.

    1984-01-01

    This is concerned with a neutron protection material made of thermoplastic or thermosetting plastic from high molecule hydrocarbon compounds with particularly high hydrogen and carbon contents as braking or shielding material (moderator) for fast neutrons. The plastic can contain boron for absorbing low energy neutrons. The material is used to manufacture foil, plates, pipes, shielding walls, components, bodies for radiation protection equipment, devices and plant and for neutron protection clothes. (orig./HP) [de

  1. Device interoperability and authentication for telemedical appliance based on the ISO/IEEE 11073 Personal Health Device (PHD) Standards.

    Science.gov (United States)

    Caranguian, Luther Paul R; Pancho-Festin, Susan; Sison, Luis G

    2012-01-01

    In this study, we focused on the interoperability and authentication of medical devices in the context of telemedical systems. A recent standard called the ISO/IEEE 11073 Personal Health Device (X73-PHD) Standards addresses the device interoperability problem by defining common protocols for agent (medical device) and manager (appliance) interface. The X73-PHD standard however has not addressed security and authentication of medical devices which is important in establishing integrity of a telemedical system. We have designed and implemented a security policy within the X73-PHD standards. The policy will enable device authentication using Asymmetric-Key Cryptography and the RSA algorithm as the digital signature scheme. We used two approaches for performing the digital signatures: direct software implementation and use of embedded security modules (ESM). The two approaches were evaluated and compared in terms of execution time and memory requirement. For the standard 2048-bit RSA, ESM calculates digital signatures only 12% of the total time for the direct implementation. Moreover, analysis shows that ESM offers more security advantage such as secure storage of keys compared to using direct implementation. Interoperability with other systems was verified by testing the system with LNI Healthlink, a manager software that implements the X73-PHD standard. Lastly, security analysis was done and the system's response to common attacks on authentication systems was analyzed and several measures were implemented to protect the system against them.

  2. Microprocessor protection devices: The present and the future

    Directory of Open Access Journals (Sweden)

    Gurevich Vladimir

    2008-01-01

    Full Text Available Paper presents the analysis of the basic constructive disadvantages of the present day microprocessor-based protective devices (MBR and offers the basic principles for creating a new MBR that can be used in newly constructed devices.

  3. Measured results and assessment of personal protection appliances against ionizing radiation

    International Nuclear Information System (INIS)

    Ge Lijuan; Lin Zhikai; Cao Jisheng; Zhu Pei; Tang Haiying; Liu Baiqun

    2011-01-01

    Objective: To monitor the protective qualities of personal protective appliances and to ensure the health and safety of radiological working personnel. Methods: The lead-equivalent thickness of personal protective appliances and materials was measured by means of standard lead slices. The lead equivalent thickness represents in terms of mm Pb. Results: 77 pieces of products and samples were measured altogether. The results indicate that the specific lead equivalents of lead-rubber plates were between 0.20-0.39 mm Pb/mm for 37 pieces of lead-rubber plates and the values of 6 pieces of samples were less than 0.25 mm Pb/mm, which did not accord with the requirement of the relational standard. 27 pieces of personal protection appliances were measured altogether. They were 12 pieces of protective clothes, 4 pieces of protective headgears, 5 pieces of protective neckpieces, 4 pieces of protective gloves and 2 pieces of protective masks. 13 pairs of lead-glass spectacles among them were measured altogether. The measured results for personal protective appliances and lead-glass spectacles showed that actually measured lead-equivalent were higher than the nominal lead-equivalent. Conclusions: The protective qualities are reliable for personal protection materials and appliances to be made in home and imported abroad. But the protective qualities of interventional protection gloves should be improved and made them better. (authors)

  4. Personalized biomedical devices & systems for healthcare applications

    Science.gov (United States)

    Chen, I.-Ming; Phee, Soo Jay; Luo, Zhiqiang; Lim, Chee Kian

    2011-03-01

    With the advancement in micro- and nanotechnology, electromechanical components and systems are getting smaller and smaller and gradually can be applied to the human as portable, mobile and even wearable devices. Healthcare industry have started to benefit from this technology trend by providing more and more miniature biomedical devices for personalized medical treatments in order to obtain better and more accurate outcome. This article introduces some recent development in non-intrusive and intrusive biomedical devices resulted from the advancement of niche miniature sensors and actuators, namely, wearable biomedical sensors, wearable haptic devices, and ingestible medical capsules. The development of these devices requires carful integration of knowledge and people from many different disciplines like medicine, electronics, mechanics, and design. Furthermore, designing affordable devices and systems to benefit all mankind is a great challenge ahead. The multi-disciplinary nature of the R&D effort in this area provides a new perspective for the future mechanical engineers.

  5. INDIVIDUAL AND ORGANIZATIONAL VARIABLES AFFECTING THE USE OF PERSONAL PROTECTIVE EQUIPMENT

    Directory of Open Access Journals (Sweden)

    TUNÇ DEMİRBİLEK

    2013-06-01

    Full Text Available Management’s safety approach and commitment are related to occupational health and safety applications in workplaces. However, personal characteristics and attitudes on their health of employees are very influential factors on occupational health and safety applications. For examine of interaction between behaviors and the health and safety applications it is required that determine of employee’s perceptions. For this reason this paper’s purpose is to establish of safety needs, attitudes and behaviors of employees and their perceptions regarding management’s safety approach and applications. The study’s focal point is use of personal protective equipment as an indicator “safety behavior”. In empirical study, assumption variables regarding the use of personal protective equipment are safety effectively, safety need, management attitudes and protective equipment conditions. The fundamental hypothesis of this paper is use of personal protective equipment is related to individual and organizational variables. Implications of research findings are to indicate impelling the workers to safety behaviour or using the personal protective equipment by their feeling of the safety behaviour and availability of personal protective equipment.

  6. Staging workers' use of hearing protection devices: application of the transtheoretical model.

    Science.gov (United States)

    Raymond, Delbert M; Lusk, Sally L

    2006-04-01

    The threat of noise-induced hearing loss is a serious concern for many workers. This study explores use of the transtheoretical model as a framework for defining stages of workers' acceptance of hearing protection devices. A secondary analysis was performed using a cross-section of data from a randomized, controlled clinical trial of an intervention to increase use of hearing protection. Use of hearing protection devices was well distributed across the theorized stages of change. Chi-square analysis and analysis of variance revealed significant differences between stages for the variables studied. Discrete stages of hearing protection device use can be identified, laying the foundation for further work investigating use of the transtheoretical model for promoting hearing protection device use. The model can provide a framework for tailoring interventions and evaluating their effects. With further development of the transtheoretical model, nurses may be able to easily identify workers' readiness to use hearing protection devices and tailor training toward that goal.

  7. 36 CFR 902.56 - Protection of personal privacy.

    Science.gov (United States)

    2010-07-01

    ... privacy. 902.56 Section 902.56 Parks, Forests, and Public Property PENNSYLVANIA AVENUE DEVELOPMENT... Protection of personal privacy. (a) Any of the following personnel, medical, or similar records is within the... invasion of his personal privacy: (1) Personnel and background records personal to any officer or employee...

  8. Novel material and structural design for large-scale marine protective devices

    International Nuclear Information System (INIS)

    Qiu, Ang; Lin, Wei; Ma, Yong; Zhao, Chengbi; Tang, Youhong

    2015-01-01

    Highlights: • Large-scale protective devices with different structural designs have been optimized. • Large-scale protective devices with novel material designs have been optimized. • Protective devices constructed of sandwich panels have the best anti-collision performance. • Protective devices with novel material design can reduce weight and construction cost. - Abstract: Large-scale protective devices must endure the impact of severe forces, large structural deformation, the increased stress and strain rate effects, and multiple coupling effects. In evaluation of the safety of conceptual design through simulation, several key parameters considered in this research are maximum impact force, energy dissipated by the impactor (e.g. a ship) and energy absorbed by the device and the impactor stroke. During impact, the main function of the ring beam structure is to resist and buffer the impact force between ship and bridge pile caps, which could guarantee that the magnitude of impact force meets the corresponding requirements. The means of improving anti-collision performance can be to increase the strength of the beam section or to exchange the steel material with novel fiber reinforced polymer laminates. The main function of the buoyancy tank is to absorb and transfer the ship’s kinetic energy through large plastic deformation, damage, or friction occurring within itself. The energy absorption effect can be improved by structure optimization or by the use of new sandwich panels. Structural and material optimization schemes are proposed on the basis of conceptual design in this research, and protective devices constructed of sandwich panels prove to have the best anti-collision performance

  9. 14 CFR 25.1357 - Circuit protective devices.

    Science.gov (United States)

    2010-01-01

    ... system or connected equipment. (b) The protective and control devices in the generating system must be designed to de-energize and disconnect faulty power sources and power transmission equipment from their...

  10. Protecting Personal Information on Social Networking Sites

    Science.gov (United States)

    Gallant, David T.

    2011-01-01

    Almost everyone uses social networking sites like Facebook, MySpace, and LinkedIn. Since Facebook is the most popular site in the history of the Internet, this article will focus on how one can protect his/her personal information and how that extends to protecting the private information of others.

  11. 14 CFR 29.1357 - Circuit protective devices.

    Science.gov (United States)

    2010-01-01

    ... faults or serious malfunction of the system or connected equipment. (b) The protective and control devices in the generating system must be designed to de-energize and disconnect faulty power sources and...

  12. Interactive lectures: Clickers or personal devices?

    Science.gov (United States)

    Morrell, Lesley J; Joyce, Domino A

    2015-01-01

    Audience response systems ('clickers') are frequently used to promote participation in large lecture classes, and evidence suggests that they convey a number of benefits to students, including improved academic performance and student satisfaction. The limitations of these systems (such as limited access and cost) can be overcome using students' personal electronic devices, such as mobile phones, tablets and laptops together with text message, web- or app-based polling systems. Using questionnaires, we compare student perceptions of clicker and smartphone based polling systems. We find that students prefer interactive lectures generally, but those that used their own device preferred those lectures over lectures using clickers. However, device users were more likely to report using their devices for other purposes (checking email, social media etc.) when they were available to answer polling questions. These students did not feel that this distracted them from the lecture, instead, concerns over the use of smartphones centred around increased battery usage and inclusivity for students without access to suitable technology. Our results suggest that students generally preferred to use their own devices over clickers, and that this may be a sensible way to overcome some of the limitations associated with clickers, although issues surrounding levels of distraction and the implications for retention and recall of information need further investigation.

  13. 77 FR 19937 - Inflatable Personal Flotation Devices

    Science.gov (United States)

    2012-04-03

    ... Advancement Act OMB Office of Management and Budget PFD Personal flotation device STP Standards Technical... using existing inflatable PFDs, and would enable marketing of existing inflatable PFDs to youth. The... approved, and thus does not affect the availability, use, or marketing of existing PFDs to or by the youth...

  14. EVALUATION OF PERSONAL COOLING DEVICES FOR A ...

    Science.gov (United States)

    The study investigated the use of personal coolers to increase worker productivity and safety while working at elevated, ambient temperatures cleaning up dioxin contaminated soil.^The study included laboratory tests to measure the thermal characteristics of the chemical protective clothing worn and the performance of ice vest and vortex personal coolers.^In addition, field tests were conducted at a dioxin clean-up site to evaluate the performance of these two types of personal coolers.^The use of personal coolers was found to be an effective method of reducing the risk of heat stress.^In addition, workers were able to work continuously in hot weather without following the procedure normally used to decrease heat stress, i.e., working one hour followed by one hour of resting.^Both types of personal coolers were acceptable for the task being performed. information

  15. Dependable Design Flow for Protection Systems using Programmable Logic Devices

    CERN Document Server

    Kwiatkowski, M

    2011-01-01

    Programmable Logic Devices (PLD) such as Field Programmable Gate Arrays (FPGA) are becoming more prevalent in protection and safety-related electronic systems. When employing such programmable logic devices, extra care and attention needs to be taken. The final synthesis result, used to generate the bit-stream to program the device, must be shown to meet the design’s requirements. This paper describes how to maximize confidence using techniques such as Formal Methods, exhaustive Hardware Description Language (HDL) code simulation and hardware testing. An example is given for one of the critical functions of the Safe Machine Parameters (SMP) system, used in the protection of the Large Hadron Collider (LHC) at CERN. CERN is also working towards an adaptation of the IEC- 61508 lifecycle designed for Machine Protection Systems (MPS), and the High Energy Physics environment, implementation of a protection function in FPGA code is only one small step of this lifecycle. The ultimate aim of this project is to cre...

  16. Efficiency and safety of percuSurge distal protection device in acute ...

    African Journals Online (AJOL)

    user

    2011-04-25

    Apr 25, 2011 ... myocardial infarction. The long-term effects of the distal protection device are still in controversy. The enhanced myocardial efficacy and recovery by aspiration of liberated debris (EMERALD) trial failed to show the effectiveness of the distal protection device in patients with AMI (Yamada and Topol, 2000).

  17. Evaluation of personal protective devices used in diagnostic radiology; Avaliacao de dispositivos de protecao individual utilizados em radiologia diagnostica

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Fernanda Cristina Salvador

    2006-07-01

    In this work protective devices of five manufacturers were evaluated according to the NBR/IEC 61331-1 and NBR/IEC 61331-3 standards. Three different methodologies (linear interpolation, Archer model and sum of exponentials) were applied for the determination of the attenuation equivalent, since the standard does not indicate how it must be determined. Moreover, the uncertainties associated to each method, and the influence of the number of measurements in the combined uncertainty were estimated. The evaluated manufacture characteristics were: accompanying document, design, materials, dimensions and label marking. For this evaluation a check list about the requirements of the NBR/IEC 61331-3 standard was elaborated. The results showed a great difference between nominal and measured attenuation equivalent values. The comparison of the results using the three methodologies showed small variations among the obtained values and among the associated uncertainties in the different methodologies. It was possible to observe that the number of measurements does not contribute significantly for the increase of the uncertainty in all three methodologies. The best methodology for the laboratory routine is the linear interpolation methodology, with five measurements for each air kerma rate value. The discrepancy between the results obtained in this work and the requirements of the applied standards show the need to adopt a compulsory certification process for protective devices, thus contributing for the increase of the radiation protection of the users. (author)

  18. Analysis of emboli during carotid stenting with distal protection device.

    Science.gov (United States)

    Chen, Chin-I; Iguchi, Yasuyuki; Garami, Zsolt; Malkoff, Marc D; Smalling, Richard W; Campbell, Morgan S; Alexandrov, Andrei V

    2006-01-01

    The newly developed multi-frequency transcranial Doppler (TCD) is able to differentiate gaseous from solid emboli. Our goal was to apply this technology to initially characterize emboli detected during carotid stenting with distal protection. Patients undergoing carotid angiography and stenting were monitored with 2-2.5 MHz TCD (Embo-Dop, DWL) over the middle cerebral artery unilateral to stent deployment. Sonographers insured optimal signal recordings during the procedures. Automated emboli detection and classification software (MultiXLab version 2.0) was applied for offline count and analysis. Monitoring using the Filter Wire EX (Boston Scientific) and ACCUNET system (Guidant Corporation) was performed. A total of 9,649 embolic signals were detected during 11 angiographic and 10 stenting procedures. An observer confirmed the signals using the International Consensus definition. Automated software classified these events into 5,900 gaseous and 3,749 solid emboli. During contrast injections without the protection device, 1,013 emboli were detected with 28% of these being solid. With deployment of the distal protection device, 8,636 emboli were found with 40% being solid (p protection device, 7,395 emboli with 42% solids were detected (p protection device still deployed, yielded 1,241 emboli with 31% solids (NS). Only 1 patient developed transient hemiparesthesia during ballooning that reduced the flow velocity to zero for 14 s. Neither gaseous nor solid emboli resulted in a mean flow velocity decrease or clinical symptoms. Microembolization frequently occurs during stenting even with deployment of the distal protection device. More solid emboli are seen during manipulations associated with lesion crossing. Although novel TCD methods yield a high frequency of embolic signals, further validation of this technique to determine the true nature, size, and number of emboli is needed.

  19. Evaluation of personal alarm devices for fire fighters

    International Nuclear Information System (INIS)

    Sharry, J.; da Roza, R.A.

    1984-01-01

    Although three of the models of the personal alarm devices (PAD) tested had received letters of acceptability and compliance from the State of California/Occupational Safety and Health Administration (Cal/OSHA), it was found that none of the models met all of the Cal/OSHA specifications. Additional tests showed other deficiencies in the PADs' design. This points out the need for the purchaser or user of such devices to specify acceptance criteria and perform his own tests

  20. Estimation of digital protection devices applicability on basis of multiple characterizing parameters

    Directory of Open Access Journals (Sweden)

    Dimitar Bogdanov

    2018-01-01

    Full Text Available The contemporary electrical power systems (EPS impose increased requirements for the functionality of the protection systems. The necessity of improved EPS stability is in some extent resulting of the increased integration of renewable sources of electrical energy. The future grid development gives perspective for connection of more converter based generations. The power electronic schemes and associated functional requirements impose necessity of high speed, sensitive, selective and reliable operation of the protection devices. These requirements have always been target of the protection equipment producers and grid operators. The electronic converting schemes specifics impose these requirements for the protection devices in more straightened way, as the converter connected generator may need to trip in shorter time than classical machine generator. In the article is presented a generalized overview of some of the characteristics of the digital “relay” protection devices, and approach for device selection is proposed. Investment planning may utilize such approach in order to have an optimal design from financial point of view.

  1. Safety of nursing staff and determinants of adherence to personal protective equipment.

    Science.gov (United States)

    Neves, Heliny Carneiro Cunha; Souza, Adenícia Custódia Silva e; Medeiros, Marcelo; Munari, Denize Bouttelet; Ribeiro, Luana Cássia Miranda; Tipple, Anaclara Ferreira Veiga

    2011-01-01

    A qualitative study conducted in a teaching hospital with 15 nursing professionals. Attempted to analyze the reasons, attitudes and beliefs of nursing staff regarding adherence to personal protective equipment. Data were collected through focus groups, analyzed by the method of interpretation of meanings, considering Rosenstock's model of health beliefs as a reference framework. Data revealed two themes: Occupational safety and Interpersonal Relationship. We identified several barriers that interfere in matters of safety and personal protective equipment, such as communication, work overload, physical structure, accessibility of protective equipment and organizational and management aspects. Adherence to personal protective equipment is determined by the context experienced in the workplace, as well as by individual values and beliefs, but the decision to use the personal protective equipment is individual.

  2. The use of hearing protection devices by older adults during recreational noise exposure.

    Science.gov (United States)

    Nondahl, D M; Cruickshanks, K J; Dalton, D S; Klein, B E K; Klein, R; Tweed, T S; Wiley, T L

    2006-01-01

    A population-based study to assess the use of hearing protection devices by older adults during noisy recreational activities was performed. The population-based Epidemiology of Hearing Loss Study was designed to measure the prevalence of hearing loss in adults residing in Beaver Dam, Wisconsin. The use of hearing protection devices during noisy recreational activities was assessed by performing three examinations over a period of 10 years (1993-1995, no. of participants (n)=3753, aged 48-92 years; 1998-2000, n=2800, aged 53-97 years; 2003-2005, n=2395, aged 58-100 years). The recreational activities included hunting, target shooting, woodworking/carpentry, metalworking, driving loud recreational vehicles, and performing yard work using either power tools or a chain saw. The prevalence of using hearing protection devices during any of these activities increased with time (9.5%, 15.0%, and 19.9% at baseline, 5 years, and 10 years, respectively). However, the use of hearing protection devices remained low for most activities. Those under the age of 65 were twice as likely to use hearing protection devices during noisy activities than were older adults. Men, those with a hearing handicap, and those with significant tinnitus were more likely to use hearing protection devices. Smokers and the less educated were less likely to use hearing protection devices. The results demonstrated that many adults expose themselves to potentially damaging recreational noise, leaving them at risk for hearing loss.

  3. 30 CFR 75.1723 - Stationary grinding machines; protective devices.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Stationary grinding machines; protective....1723 Stationary grinding machines; protective devices. (a) Stationary grinding machines other than... the wheel. (3) Safety washers. (b) Grinding wheels shall be operated within the specifications of the...

  4. Haptics using a smart material for eyes-free interaction in personal devices

    Science.gov (United States)

    Wang, Huihui; Lane, William Brian; Pappas, Devin; Duque, Bryam; Leong, John

    2014-03-01

    In this paper we present a prototype using a dry ionic polymer metal composite (IPMC) in interactive personal devices such as bracelet, necklace, pocket key chain or mobile devices for haptic interaction when audio or visual feedback is not possible or practical. This prototype interface is an electro-mechanical system that realizes a shape-changing haptic display for information communication. A dry IPMC will change its dimensions due to the electrostatic effect when an electrical potential is provided to them. The IPMC can operate at a lower voltage (less than 2.5V) which is compatible with requirements for personal electrical devices or mobile devices. The prototype consists of the addressable arrays of the IPMCs with different dimensions which are deformable to different shapes with proper handling or customization. 3D printing technology will be used to form supporting parts. Microcontrollers (about 3cm square) from DigiKey will be imbedded into this personal device. An Android based mobile APP will be developed to talk with microcontrollers to control IPMCs. When personal devices receive information signals, the original shape of the prototype will change to another shape related to the specific sender or types of information sources. This interactive prototype can simultaneously realize multiple methods for conveying haptic information such as dimension, force, and texture due to the flexible array design. We conduct several studies of user experience to explore how users' respond to shape change information.

  5. Consumer protection issues in energy: a guide for attorneys general. Insulation, solar, automobile device, home devices

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, Harry I.; Hulse, William S.; Jones, Robert R.; Langer, Robert M.; Petrucelli, Paul J.; Schroeder, Robert J.

    1979-11-01

    The guide attempts to bring together two important and current issues: energy and consumer protection. Perhaps the most basic consumer-protection issue in the energy area is assuring adequate supplies at adequate prices. It is anticipated, though, that consumers will want to consider new ways to lower enegy consumption and cost, and will thus be susceptible to fraudulent energy claims. Information is prepared on insulation, solar, energy-saving devices for the home, and energy-saving devices for the automobile.

  6. 76 FR 80402 - Certain Personal Data and Mobile Communications Devices and Related Software; Final Determination...

    Science.gov (United States)

    2011-12-23

    ... importation of infringing personal data and mobile communications devices and related software. The Commission... importation of certain personal data and mobile communications devices and related software that infringe... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-710] Certain Personal Data and Mobile...

  7. Mandatory certification of personal protection equipment against ionizing radiation

    International Nuclear Information System (INIS)

    Palacios, Tulio A.

    2000-01-01

    This paper analyze the regulations establishing mandatory certification of personal protection equipment, including those aim to protect against ionizing radiation due to the external irradiation and to the radioactive contamination. (author)

  8. Personal annunciation device

    Science.gov (United States)

    Angelo, Peter [Oak Ridge, TN; Younkin, James [Oak Ridge, TN; DeMint, Paul [Kingston, TN

    2011-01-25

    A personal annunciation device (PAD) providing, in an area of interest, compensatory annunciation of the presence of an abnormal condition in a hazardous area and accountability of the user of the PAD. Compensatory annunciation supplements primary annunciation provided by an emergency notification system (ENS). A detection system detects an abnormal condition, and a wireless transmission system transmits a wireless transmission to the PAD. The PAD has a housing enclosing the components of the PAD including a communication module for receiving the wireless transmission, a power supply, processor, memory, annunciation system, and RFID module. The RFID module has an RFID receiver that listens for an RFID transmission from an RFID reader disposed in a portal of an area of interest. The PAD identifies the transmission and changes its operating state based on the transmission. The RFID readers recognize, record, and transmit the state of the PAD to a base station providing accountability of the wearer.

  9. 30 CFR 77.401 - Stationary grinding machines; protective devices.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Stationary grinding machines; protective... OF UNDERGROUND COAL MINES Safeguards for Mechanical Equipment § 77.401 Stationary grinding machines; protective devices. (a) Stationary grinding machines other than special bit grinders shall be equipped with...

  10. The radiation protective devices for interventional procedures using computed tomography

    International Nuclear Information System (INIS)

    Iida, Hiroji; Chabatake, Mitsuhiro; Shimizu, Mitsuru; Tamura, Sakio

    2002-01-01

    A scattered dose and a surface dose from phantom measurements during interventional procedures with computed tomography (IVR-CT) were evaluated. To reduce the personnel exposure in IVR-CT, the new protective devices were developed and its effect evaluated. Two radiation protection devices were experimentally made using a lead vinyl sheet with lead equivalent 0.125 mmPb. The first device is a lead curtain which shields the space of CT-gantry and phantom for the CT examination. The second device is a lead drape which shields on the phantom surface adjacent to the scanning plane for the CT-fluoroscopy. Scattered dose and phantom surface dose were measured with an abdominal phantom during Cine-CT (130 kV, 150 mA, 5 seconds, 10 mm section thickness). They were measured by using ionization chamber dosimeter. They were measured with and without a lead curtain and a lead drape. Scattered dose rate was measured at distance of 50-150 cm from the scanning plane. And, surface dose was measured at distance of 4-21 cm from the scanning plane on the phantom. On operator's standing position, scattered dose rates were from 8.4 to 11.6 μGy/sec at CT examination. The lead curtain and the lead drape reduced scattered dose rate at distance of 50 cm from the scanning plane by 66% and 58.3% respectively. Surface dose rate were 118 μGy/sec at distance of 5 cm from the scanning plane at CT-fluoroscopy. The lead drape reduced the surface dose by 60.5%. High scattered exposure to personnel may occur during interventional procedures using CT. They were considerably reduced during CT-arteriography by attaching the lead curtain in CT equipment. And they were substantially reduced during CT-fluoroscopy by placing the lead drape adjacent to the scanning plane, in addition, operator's hand would be protected from unnecessary radiation scattered by phantom. It was suggested that the scattered exposure to personnel could be sufficiently reduced by using radiation protection devices in IVR-CT. The

  11. Adjustable radiation protection device of the fluoroscope DG 10

    International Nuclear Information System (INIS)

    Hoermann, D.

    1980-01-01

    In cooperation with the 'VEB Transformatoren- und Roentgenwerk Hermann Matern', Dresden, an adjustable radiation protection device has been developed. This supplementary equipment for fluoroscopes ensures a sufficient protection of the gonads against undesirable X radiation, can be handled easily and does not annoy patients, esp. children

  12. Personal Communication Device Use by Nurses Providing In-Patient Care: Survey of Prevalence, Patterns, and Distraction Potential.

    Science.gov (United States)

    McBride, Deborah L; LeVasseur, Sandra A

    2017-04-13

    Coincident with the proliferation of employer-provided mobile communication devices, personal communication devices, including basic and enhanced mobile phones (smartphones) and tablet computers that are owned by the user, have become ubiquitous among registered nurses working in hospitals. While there are numerous benefits of personal communication device use by nurses at work, little is known about the impact of these devices on in-patient care. Our aim was to examine how hospital-registered nurses use their personal communication devices while doing both work-related and non‒work-related activities and to assess the impact of these devices on in-patient care. A previously validated survey was emailed to 14,797 members of two national nursing organizations. Participants were asked about personal communication device use and their opinions about the impact of these devices on their own and their colleagues' work. Of the 1268 respondents (8.57% response rate), only 5.65% (70/1237) never used their personal communication device at work (excluding lunch and breaks). Respondents self-reported using their personal communication devices at work for work-related activities including checking or sending text messages or emails to health care team members (29.02%, 363/1251), as a calculator (25.34%, 316/1247), and to access work-related medical information (20.13%, 251/1247). Fewer nurses reported using their devices for non‒work-related activities including checking or sending text messages or emails to friends and family (18.75%, 235/1253), shopping (5.14%, 64/1244), or playing games (2.73%, 34/1249). A minority of respondents believe that their personal device use at work had a positive effect on their work including reducing stress (29.88%, 369/1235), benefiting patient care (28.74%, 357/1242), improving coordination of patient care among the health care team (25.34%, 315/1243), or increasing unit teamwork (17.70%, 220/1243). A majority (69.06%, 848/1228) of

  13. Protecting personal information: Implications of the Protection of Personal Information (POPI) Act for healthcare professionals.

    Science.gov (United States)

    Buys, M

    2017-10-31

    Careless handling of patient information in daily medical practice can result in Health Professions Council of South Africa sanction, breach of privacy lawsuits and, in extreme cases, serious monetary penalty or even imprisonment. This review will focus on the Protection of Personal Information (POPI) Act (No. 4 of 2013) and the implications thereof for healthcare professionals in daily practice. Recommendations regarding the safeguarding of information are made.

  14. Developing biomedical devices design, innovation and protection

    CERN Document Server

    Andreoni, Giuseppe; Colombo, Barbara

    2013-01-01

    During the past two decades incredible progress has been achieved in the instruments and devices used in the biomedical field. This progress stems from continuous scientific research that has taken advantage of many findings and advances in technology made available by universities and industry. Innovation is the key word, and in this context legal protection and intellectual property rights (IPR) are of crucial importance. This book provides students and practitioners with the fundamentals for designing biomedical devices and explains basic design principles. Furthermore, as an aid to the dev

  15. Physical limitations of semiconductor devices defects, reliability and esd protection

    CERN Document Server

    Vashchenko, V A

    2008-01-01

    Provides an important link between the theoretical knowledge in the field of non-linier physics and practical application problems in microelectronics. This title focuses on power semiconductor devices and self-triggering pulsed power devices for ESD protection clamps.

  16. Personal health record systems and their security protection.

    Science.gov (United States)

    Win, Khin Than; Susilo, Willy; Mu, Yi

    2006-08-01

    The objective of this study is to analyze the security protection of personal health record systems. To achieve this we have investigated different personal health record systems, their security functions, and security issues. We have noted that current security mechanisms are not adequate and we have proposed some security mechanisms to tackle these problems.

  17. Safety work with MRI devices in medicine

    International Nuclear Information System (INIS)

    Zivkovic, D.; Hrnjak, M.

    1999-01-01

    This paper gives the basis of biological effects of physical factors which could affect personnel working on MRI devices and patients, and corresponding protection measures. Medical personnel working with MRI devices and patients could be exposed to static magnetic field, time varying fields and radiofrequency radiation, danger from electric current and chemical matters, and there is a high risk from moving metal objects which could wound the persons near-by. The protection from static magnetic field could be ensured by increasing the distance from the source. If MRI device is put in Faradays cage it could be corresponding protection of radiofrequency radiation. (author)

  18. Investigation of surge protective devices operation of a wind generator

    International Nuclear Information System (INIS)

    Dimitrov, D.; Vasileva, M.

    2008-01-01

    The interest to the investments in a wind energetics increases in the last years. The wind energetics is the fastest developing direction in the energetics in global scale. The wind energy is more attractive because its prices are lower in comparison of the other technologies for generating energy. The right choice of the surge protective devices has the important meaning on building and exploitation of the wind generators. The aim of this paper is investigation of the surge protective devices operation when they are installation to a wind generator. (authors)

  19. Specificity of psychon structure forming the personality of transgressive and protective spouses

    Directory of Open Access Journals (Sweden)

    Dakowicz Andrzej

    2015-12-01

    Full Text Available In terms of psychotransgressionism, personality is a network of five equipollent psychons, the content of which determines the personality’s functioning. The strength and power of the individual psychons underlies the tendency to undertake transgressive actions. In this study, we hypothesized that transgressive spouses are characterized by greater potential strength, greater power of cognitive, instrumental, motivational, emotional, and personal psychons than protective spouses. We operationalized all psychons, created the appropriate research tools, and then studied married couples. Using the Transgression Scale developed by Studenski, we found a group of spouses with higher levels of transgression (transgressive, and a group of spouses with lower levels of transgression (protective. Transgressive wives are characterized by better knowledge about their husbands’ operational sphere, and are more aware of personal beliefs than protective wives. Similarly, transgressive husbands have greater knowledge of their wives’ operational sphere, stronger cognitive needs, and weaker personal needs than protective husbands. Transgressive husbands are characterized by a positive affective shift and have a greater awareness of personal beliefs than protective husbands. The potential brought into interpersonal relationships by transgressive spouses may create a climate conducive to building a satisfying marital relationship.

  20. Concept for trusted personal devices in a mobile and networked environment

    NARCIS (Netherlands)

    Bormann, Frank C.; Manteau, Laurent; Linke, Andreas; Pailles, Jean C.; van Dijk, Johannes A.G.M.

    2006-01-01

    In this article we present a concept for Trusted Personal Devices, which are intended to be the common platform for the next generation of Smart Cards and other secure devices in mobile and networked environments. The concept is based on a classification of technical profiles for different potential

  1. Turbine protecting device in a BWR type nuclear power plant

    International Nuclear Information System (INIS)

    Kasuga, Hajime; Oka, Yoko.

    1984-01-01

    Purpose: To prevent highly humid steams from flowing into the turbine upon abnormal reduction in the reactor water level in order to ensure the turbine soundness, as well as in order to trip the turbine with no undesired effect on the reactor. Constitution: A protection device comprising a judging device and a timer are disposed in a BWR type reactor, in order to control a water level signal from a reactor water level gage. If the reactor water level is reduced during rated power operation, steams are kept to be generated due to decay heat although reactor is scramed. When a signal from the reactor water level detector is inputted to the protection device, a trip signal is outputted by way of a judging device after 15 second by means of the timer, when the main steam check valve is closed to trip the turbine. With this delay of time, abrupt increase in the pressure of the reactor due to sudden shutdown can be prevented. (Nakamoto, H)

  2. An experimental study of UWB device-free person detection and ranging

    NARCIS (Netherlands)

    Kilic, Y.; Wymeersch, Henk; Meijerink, Arjan; Bentum, Marinus Jan; Scanlon, W.G.

    2013-01-01

    Passive person detection and localization is an emerging area in UWB localization systems, whereby people are not required to carry any UWB ranging device. Based on experimental data, we propose a novel method to detect static persons in the absence of template waveforms, and to compute distances to

  3. 46 CFR 28.110 - Life preservers or other personal flotation devices.

    Science.gov (United States)

    2010-10-01

    ... be equipped with at least one immersion suit, exposure suit, or wearable personal flotation device of..., from both the individual's normal work station and berthing area. If there is no location accessible to both the work station and the berthing area, an appropriate device must be stowed in both locations...

  4. 30 CFR 77.600 - Trailing cables; short-circuit protection; disconnecting devices.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Trailing cables; short-circuit protection... AREAS OF UNDERGROUND COAL MINES Trailing Cables § 77.600 Trailing cables; short-circuit protection; disconnecting devices. Short-circuit protection for trailing cables shall be provided by an automatic circuit...

  5. Related factors to workers' use of hearing protection device in knitting & ppinning factories of Yazd city based on Protection Motivation Theory

    Directory of Open Access Journals (Sweden)

    A. Barkhordi

    2009-10-01

    Full Text Available Background and aimsNoise-Induced Hearing Loss (NIHL is an important occupational disorder. High percentage of workers in occupational environments did not use the hearing protection device against harmful noise. This study was carried out to study factors related to workers' use of Hearing protection Device in Knitting & spinning factories of Yazd city based on protection motivation theory.MethodsIn this cross-sectional analytical study 280 workers of the knitting & spinning factories of Yazd City who exposed to harmful noise (over 85dB selected among the three factories by cluster sampling. The data gathered via exclusive interviews with selected workers  using the questionnaire designed based on protection motivation theory and were analyzedResults42/5 percent of workers permanently used hearing protection devices, and 20/7 percent of workers never use.There was a significant correlation between the age of workers and the mean score components of PMT; perceived severity, perceived vulnerability, perceived response efficacy and protection motivation. There was also a significant correlation between the work experience and the mean score of PMT factors; perceived severity, perceived response efficacy and perceived vulnerability. Also there was a significant correlation between workers' education level and the mean score of perceived response efficacy and there was a significant correlation between protection motivation and the mean score components of PMT; perceived vulnerability, perceived self-efficacy, perceived response efficacy, perceived costs and behaviorConclusionRegarding the significant correlations between the more constructs of PMT and protection motivation of workers for using hearing protective device, designing educational program based on PMT to increase hearing protection devices usage among workers is recommended.

  6. Personalized ventilation: evaluation of different air terminal devices

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Cermak, Radim; Majer, M.

    2002-01-01

    Personalized ventilation (PV) aims to provide clean air to the breathing zone of occupants. Its performance depends to a large extent on the supply air terminal device (ATD). Five different ATDs were developed, tested and compared. A typical office workplace consisting of a desk with mounted ATDs...... was simulated in a climate chamber. A breathing thermal manikin was used to simulate a human being. Experiments at room air temperatures of 26 and 20 deg.C and personalized air temperatures of 20 deg.C supplied from the ATDs were performed. The flow rate of personalized air was changed from less than 5 up to 23...... l/s. Tracer gas was used to identify the amount of personalized air inhaled by the manikin as well as the amount of exhaled air re-inhaled. The heat loss from the body segments of the thermal manikin was measured and used to calculate the equivalent temperature for the whole body as well as segments...

  7. How Do I Know? A Guide to the Selection of Personal Protective Equipment for Use in Responding to A Release of Chemical Warfare Agents

    Energy Technology Data Exchange (ETDEWEB)

    Foust, C.B.

    1999-05-01

    An incident involving chemical warfare agents requires a unique hazardous materials (HAZMAT) response. As with an HAZMAT event, federal regulations prescribe that responders must be protected from exposure to the chemical agents. But unlike other HAZMAT events, special considerations govern selection of personal protective equipment (PPE). PPE includes all clothing, respirators and monitoring devices used to respond to a chemical release. PPE can differ depending on whether responders are military or civilian personnel.

  8. 29 CFR 1926.95 - Criteria for personal protective equipment.

    Science.gov (United States)

    2010-07-01

    ..., DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Personal Protective and Life... in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or... construction for the work to be performed. (d) Payment for protective equipment. (1) Except as provided by...

  9. Toward Better Personal Ballistic Protection

    Science.gov (United States)

    2014-03-04

    Toward Better Personal Ballistic Protection Manon Bolduc1, Jason Lo2, Ruby Zhang2, Dan Walsh2, Shuqiong Lin3, Benoit Simard3, Ken Bosnick4, Mike...presenc particulate gr atly increase ceramic mad er, knowing e ceramic ma the alumina y on the mat a layered with s on the coat stantial prope C) magnif...mic fiber ma site ceramics such, thod. this fore, on of t has 8. CONCLUSION In an attempt to improve the failure resistance of ceramic

  10. Preventive protection device and method for bottom of reactor pressure vessel

    International Nuclear Information System (INIS)

    Hayashi, Eisaku; Kurosawa, Koichi; Furukawa, Hideyasu; Morinaka, Ren; Enomoto, Kunio; Otaka, Masahiro; Yoshikubo, Fujio; Chiba, Noboru; Sato, Kazunori.

    1995-01-01

    In a preventive protection device for improving stresses in reactor structural components by jetting highly pressurized water with cavitation bubbles from a jetting nozzle toward structural components in a reactor pressure vessel, a fixed structure to a CRD housing is provided with a rotational body attached to the structure, a multi joint arm and a jetting nozzle supported to the multi joint arm. The jetting nozzle is disposed at a position where the center of the jetting deviates from the center of the CRD housing. In addition, a monitoring camera is disposed for displaying the target for preventive protection. The state of stresses on a plurality of targets for preventive protection can be improved by the preventive protection device at a fixed position in the bottom of a reactor pressure vessel where housings stand densely, thereby enabling to attain the preventive protection operation easily and rapidly. (N.H.)

  11. Using Personal Portable Devices as Learning Tools in the English Class

    Science.gov (United States)

    Herrera Díaz, Luz Edith; Cruz Ramos, María de los Milagros; Sandoval Sánchez, Mario Alberto

    2014-01-01

    A group of university students used a variety of personal portable devices (cellphones, tablets, laptops, and netbooks) which distracted them in English class. This qualitative action research aimed to implement activities entailing the use of such devices and to learn their impact on students' learning and the use of English in class. Thus, a…

  12. 75 FR 17434 - In the Matter of Certain Personal Data and Mobile Communications Devices and Related Software...

    Science.gov (United States)

    2010-04-06

    ... Mobile Communications Devices and Related Software; Notice of Investigation AGENCY: U.S. International... certain personal data and mobile communications devices and related software by reason of infringement of... after importation of certain personal data or mobile communications devices or related software that...

  13. Personal Data Protection in New Zealand: Lessons for South Africa ...

    African Journals Online (AJOL)

    In 1995 the European Union adopted a Directive on data protection. Article 25 of this Directive compels all EU member countries to adopt data protection legislation and to prevent the transfer of personal data to non-EU member countries (\\'third countries\\') that do not provide an adequate level of data protection. Article 25 ...

  14. Gender and other factors associated with the use of hearing protection devices at work

    Directory of Open Access Journals (Sweden)

    Tatiane Costa Meira

    2015-01-01

    Full Text Available OBJECTIVE To analyze whether sociodemographic, occupational, and health-related data are associated with the use of hearing protection devices at work, according to gender.METHODS A cross-sectional study was conducted in 2006, using a random sample of 2,429 workers, aged between 18 and 65 years old, from residential sub-areas in Salvador, BA, Northeastern Brazil. Questionnaires were used to obtain sociodemographic, occupational, and health-related data. Workers who reported that they worked in places where they needed to shout in order to be heard were considered to be exposed to noise. Exposed workers were asked whether they used hearing protection devices, and if so, how frequently. Analyses were conducted according to gender, with estimates made about prevalence of the use of hearing protection devices, prevalence ratios, and their respective 95% confidence intervals.RESULTS Twelve percent (12.3% of study subjects reported that they were exposed to noise while working. Prevalence of the use of hearing protection devices was 59.3% for men and 21.4% for women. Men from higher socioeconomic levels (PR = 1.47; 95%CI 1.14;1.90 and who had previous audiometric tests (PR = 1.47; 95%CI 1.15;1.88 were more likely to use hearing protection devices. For women, greater perceived safety was associated with the use of protection devices (PR = 2.92; 95%CI 1.34;6.34. This perception was specifically related to the presence of supervisors committed to safety (PR = 2.09; 95%CI 1.04;4.21, the existence of clear rules to prevent workplace injuries (PR = 2.81; 95%CI 1.41;5.59, and whether they were informed about workplace safety (PR = 2.42; 95%CI 1.23;4.76.CONCLUSIONS There is a gender bias regarding the use of hearing protection devices that is less favorable to women. The use of such devices among women is positively influenced by their perception of a safe workplace, suggesting that gender should be considered as a factor in hearing conservation programs.

  15. Occupational Noise Pollution and Hearing protection in selected industries

    Directory of Open Access Journals (Sweden)

    Ghorbanali Mohammadi

    2014-01-01

    Full Text Available ABSTRACT The use of technology in industries is ever increasing. With the introduction of this technology come new safety and human performance concerns. Hearing loss caused by industrial noise has been recognized for many years, and protection of employee hearing has been made mandatory by governmental agencies. This paper presents an investigation of occupational noise exposure and Personal hearing protective devices (PHPD in selected industries in the south-eastern Iran. A questionnaire has been used to collect data for workers with high noise exposure and Personal hearing protective devices (PHPD. The subjects were 354 industrial workers expose to noise pressure levels greater than the action level defined in Iranian legislation (85dB (A 8h/d. The results of this study indicated that only younger workers with minor professional experience and with high educational background are used PHPD to protect and preserve their hearing. The finding of this study shows that approximately 75% of the workers with age 18-36 reported the use of personal protective Devices at all the time, and 73% of workers with age more than 46 years old reported that they had never used them PHPD, even though it was mandatory in their workplaces. Statistical data show that, the percentage of male workers (82 with age more than 37 years old having headaches at workplace are higher than female (3.4 with the same age groups. A noise training and education program must be developed for industrial employees in order to protect them from hazardous noise pollution. Employers must play an important role in promoting the regular use of Personal hearing protective devices. Noise level in work areas must be considered in the early design of Hearing Conservation Program.

  16. Effectiveness of ultraviolet light personal protective equipment used ...

    African Journals Online (AJOL)

    Journal of Agriculture, Science and Technology ... (UV) light personal protective equipment (PPE) used by arc welders in the informal sector. ... all had formal education: 31.1% had primary school level as the highest attained education level, ...

  17. Providing disabled persons in developing countries access to computer games through a novel gaming input device

    CSIR Research Space (South Africa)

    Smith, Andrew C

    2011-01-01

    Full Text Available A novel input device is presented for use with a personal computer by persons with physical disabilities who would otherwise not be able to enjoy computer gaming. This device is simple to manufacture and low in cost. A gaming application...

  18. 77 FR 40083 - Certain Personal Data and Mobile Communications Devices and Related Software; Institution of a...

    Science.gov (United States)

    2012-07-06

    ... importation of certain personal data and mobile communications devices and related software. 75 FR 17434 (Apr... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-710] Certain Personal Data and Mobile Communications Devices and Related Software; Institution of a Formal Enforcement Proceeding; Denial of Request...

  19. Chlorobenzylidenemalonitrile Gas Exposure from A Novelty Personal-Protection Gun

    Directory of Open Access Journals (Sweden)

    Dong, Christopher

    2007-05-01

    Full Text Available We present an unusual case of chlorobenzylidenemalonitrile (CS tear-gas exposure from the unwitting discharge of a personal-protection handgun loaded with CS gas. The gun was in a bag of toys purchased from a local thrift store and was discharged by a child. The responding paramedic presumptively identified the substance as CS based solely on personal experience. This recognition led to suboptimal field management of the incident with the paramedic failing to follow the standard operating procedures for an unknown chemical exposure. As this was a benign agent, there were no serious consequences. This case highlights the pre-hospital and emergency department challenges associated with the management of an unknown chemical exposure and the potential consequences if the chemical is a toxic substance. A methodical approach following established protocols can reduce the potential for negative outcomes. Review of the literature found no other report of CS gas exposure from such a personal-protection weapon.

  20. Mobile Device Security: Perspectives of Future Healthcare Workers.

    Science.gov (United States)

    Hewitt, Barbara; Dolezel, Diane; McLeod, Alexander

    2017-01-01

    Healthcare data breaches on mobile devices continue to increase, yet the healthcare industry has not adopted mobile device security standards. This increase is disturbing because individuals are often accessing patients' protected health information on personal mobile devices, which could lead to a data breach. This deficiency led the researchers to explore the perceptions of future healthcare workers regarding mobile device security. To determine healthcare students' perspectives on mobile device security, the investigators designed and distributed a survey based on the Technology Threat Avoidance Theory. Three hundred thirty-five students participated in the survey. The data were analyzed to determine participants' perceptions about security threats, effectiveness and costs of safeguards, self-efficacy, susceptibility, severity, and their motivation and actions to secure their mobile devices. Awareness of interventions to protect mobile devices was also examined. Results indicate that while future healthcare professionals perceive the severity of threats to their mobile data, they do not feel personally susceptible. Additionally, participants were knowledgeable about security safeguards, but their knowledge of costs and problems related to the adoption of these measures was mixed. These findings indicate that increasing security awareness of healthcare professionals should be a priority.

  1. Personal protective equipment for registration purposes of pesticides

    NARCIS (Netherlands)

    Gerritsen-Ebben, M.G.; Brouwer, D.H.; Hemmen, J.J. van

    2007-01-01

    Regulatory authorities in North America, Europe and Australia use different approaches for the estimation of exposure reduction effectiveness of personal protective equipment (PPE) in registration processes of agrochemical pesticides. TNO has investigated current views and facts for the use of

  2. Evaluation of the use of personal protective equipment in radiodiagnostic services in Sergipe

    International Nuclear Information System (INIS)

    Santos, Lucas R. dos; Oliveira, Celso A.; Silva, Fabio A.R.; Souza, Divanizia N.

    2008-01-01

    The theme ionizing radiation is frequently associated with danger. Therefore this subject induces to think about accessories to personal protection. These accessories can contain metal heavy (as example, lead) so that we have an efficient protection. Our analysis was done with the main objective of evidence that is not enough the radiodiagnostic services have personal protective equipment to disposal to the radiology technicians have an efficient protection, because the procedures with ionizing radiation will be safe only with the use accomplish of the security procedures and of adequate use and storing of personal protective equipment. In our analysis the accessories in question were the lead rubber X-ray protection aprons and thyroid gland protectors. We have tested these accessories through of a similar methodology utilized to checking the half-value layer of the X-ray units. It was investigated also the importance given to use of these accessories by the radiology technicians. (author)

  3. 78 FR 48683 - National Institute for Occupational Safety and Health (NIOSH) Personal Protective Technology (PPT...

    Science.gov (United States)

    2013-08-09

    ... Technology (PPT) Program; Framework Document for the Healthcare Worker Personal Protective Equipment Action... titled ``Framework for Setting the NIOSH PPT Program Action Plan for Healthcare Worker Personal... NIOSH personal protective technology (PPT) program publishes and periodically updates its research...

  4. Retinal artery occlusion during carotid artery stenting with distal embolic protection device.

    Science.gov (United States)

    Kohara, Kotaro; Ishikawa, Tatsuya; Kobayashi, Tomonori; Kawamata, Takakazu

    2018-01-01

    Retinal artery occlusion associated with carotid artery stenosis is well known. Although it can also occur at the time of carotid artery stenting, retinal artery occlusion via the collateral circulation of the external carotid artery is rare. We encountered two cases of retinal artery occlusion that were thought to be caused by an embolus from the external carotid artery during carotid artery stenting with a distal embolic protection device for the internal carotid artery. A 71-year-old man presented with central retinal artery occlusion after carotid artery stenting using the Carotid Guardwire PS and a 77-year-old man presented with branch retinal artery occlusion after carotid artery stenting using the FilterWire EZ. Because additional new cerebral ischaemic lesions were not detected in either case by postoperative diffusion-weighted magnetic resonance imaging, it was highly likely that the debris that caused retinal artery occlusion passed through not the internal carotid artery but collaterals to retinal arteries from the external carotid artery, which was not protected by a distal embolic protection device. It is suggested that a distal protection device for the internal carotid artery alone cannot prevent retinal artery embolisation during carotid artery stenting and protection of the external carotid artery is important to avoid retinal artery occlusion.

  5. Electronic Contracts and the Personal data Protection of the Consumer: Sources Dialogue Between the Consumer Protection Code and the Internet Civil Mark.

    Directory of Open Access Journals (Sweden)

    Rosane Leal Da Silva

    2016-10-01

    Full Text Available This paper analyzes the personal data protection of the consumer and your vulnerability in interactive electronic contracts, aiming to point means of defense. For this, uses the deductive approach and starts of the electronic contracting to discuss the legal protection of the consumer in light of the capturing and processing of personal data by the furnisher. Considering the absence of law about personal data, concludes that electronic contracting expands the consumer vulnerability, which requires the principles application of the Consumer Protection Code, adding the Internet Civil Mark in relation to the privacy protection.

  6. Tests of microprocessor-based relay protection devices: Problems and solutions

    Directory of Open Access Journals (Sweden)

    Gurevich Vladimir

    2009-01-01

    Full Text Available Usually, the operational condition of relay protection devices is checked with specific settings used for the relay operation in a certain network point. In the author's opinion in order to verify the proper operation of complex multifunctional microprocessor-based protection devices (MPD at their inspection, start-up after repairs or during periodic tests there is no need to use the actual settings at which the relay is to be operated in a certain network's point. It should be tested for proper operation at several of its most critical preset characteristic points as well as in several preset characteristics constituting its most complicated (combined operation modes, including the dynamic operation modes with preset transition processes specific for standard power networks (not necessarily for a specific point. The proposed set of actions for the unification of software platforms of the modern, microprocessor-based relay protection test systems will enable examination of modern MPD in an absolutely new way. .

  7. New concept of microprocessor protective devices design

    Directory of Open Access Journals (Sweden)

    Gurevich Vladimir

    2010-01-01

    Full Text Available Transition from electromechanical to digital protective relays is accompanied with serious technical problems. The author offers a new approach in designing the digital relays capable of solving these problems. It is proposed to construct digital relays in the form of standard modules from which it would be possible to assemble the digital relay in the same way as now a personal computer.

  8. 29 CFR 1977.5 - Persons protected by section 11(c).

    Science.gov (United States)

    2010-07-01

    ... OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 General § 1977.5 Persons protected by section 11(c). (a) All employees are afforded the full protection of section 11(c). For purposes of the Act, an employee is defined... Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION...

  9. Smart Electrochemical Energy Storage Devices with Self-Protection and Self-Adaptation Abilities.

    Science.gov (United States)

    Yang, Yun; Yu, Dandan; Wang, Hua; Guo, Lin

    2017-12-01

    Currently, with booming development and worldwide usage of rechargeable electrochemical energy storage devices, their safety issues, operation stability, service life, and user experience are garnering special attention. Smart and intelligent energy storage devices with self-protection and self-adaptation abilities aiming to address these challenges are being developed with great urgency. In this Progress Report, we highlight recent achievements in the field of smart energy storage systems that could early-detect incoming internal short circuits and self-protect against thermal runaway. Moreover, intelligent devices that are able to take actions and self-adapt in response to external mechanical disruption or deformation, i.e., exhibiting self-healing or shape-memory behaviors, are discussed. Finally, insights into the future development of smart rechargeable energy storage devices are provided. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. A Personal Context-Aware Multi-Device Coaching Service that Supports a Healthy Lifestyle

    NARCIS (Netherlands)

    op den Akker, Hendrikus J.A.; Klaassen, Randy; Lavrysen, Tine; Geleijnse, Gijs; van Halteren, Aart; Schwietert, Henk; van der Hout, Marloes

    2011-01-01

    This paper describes work in progress in the European Artemis project Smarcos. Smarcos focuses on interusability of multi-device embedded and networked services. The work presented here is devoted to the development of context-aware personal coaching service systems that give users personalized

  11. Qualification criteria for persons responsible for radiation protection

    International Nuclear Information System (INIS)

    Wehner, G

    1980-01-01

    A survey of the qualification criteria included in the German atomic law (Atomic Energy Act, Radiological Protection Ordinance and X-ray Protection Ordinance) for persons responsible for radiation protection is given. Especially the various activities for which a health physics officer is required, the range of qualification in each case and the way the qualification has to be proved, are pointed out. Also the different guides that are issued to complete the legal requirements are mentioned. The definitions of the term qualification for health physics given in the different guides are cited and it is shown, that the qualification of a healt physics officer has to be based on the three criteria (I) vocational training. (II) professional experience and (III) the necessary knowledge in radiation protection. (orig./HP) [de

  12. Health care professionals’ perception of security of personal health devices

    Directory of Open Access Journals (Sweden)

    Ondiege B

    2017-04-01

    Full Text Available Brian Ondiege, Malcolm Clarke Department of Computer Science, College of Engineering, Design and Physical Sciences, Brunel University London, UK Abstract: With the rapid advances in the capabilities of telehealth devices and their increasing connection to the Internet, security is becoming an issue of major concern. Therefore, the perceptions of the health care professionals regarding security are of interest, as the patients trust them to make informed decisions on issues concerning their privacy, data, and health. Eight health care professionals were interviewed to determine their perceptions and knowledge of security in health care. The research further examines one specific aspect of security which is considered of significant concern: the authenticity of a device being from the actual manufacturer and not a counterfeit. This research proposes device registration together with digital signatures and one-time passwords to address the issue of counterfeit remote patient-monitoring devices and identify and authenticate the user of the device. Keywords: telehealth security, health care professionals’ perception, personal health device, authentication

  13. Implementation of Transformer Protection by Intelligent Electronic Device for Different Faults

    OpenAIRE

    Y V Aruna, Beena S

    2015-01-01

    Protection of power system equipments was traditionally done by using electromagnetic relay, static relays, and numerical relays. At present the microprocessor based relays are replacing the old Electromagnetic relays because of their high level accuracy and fast operation. RET670(Transformer protection relay ), an IED (INTELLIGENT ELECTRONIC DEVICE) provides fast and selective protection, monitoring, and control of all types of transformer. The configured IED is tested under diff...

  14. The design of a wireless portable device for personalized ultraviolet monitoring

    Science.gov (United States)

    Amini, Navid; Matthews, Jerrid E.; Vahdatpour, Alireza; Sarrafzadeh, Majid

    2009-08-01

    The skin care product market is growing due to the threat of ultraviolet (UV) radiation caused by the destruction of the ozone layer, increasing demand for tanning, and the tendency to wear less clothing. Accordingly, there is a potential demand for a personalized UV monitoring system, which can play a fundamental role in skin cancer prevention by providing measurements of UV radiation intensities and corresponding recommendations. Furthermore, the need for such device becomes more vital since it has turned out that in some places (e.g., on snowy mountains) the UV exposure gets doubled, while individuals are unaware of this fact. This paper highlights the development and initial validation of a wireless and portable embedded system for personalized UV monitoring which is based on a novel software architecture, a high-end UV sensor, and conventional PDA (or a cell phone). In terms of short-term applications, by calculating the UV index, it informs the users about their maximum recommended sun exposure time by taking their skin type and sun protection factor (SPF) of the applied sunscreen into consideration. As for long-term applications, given that the damage caused by UV light is accumulated over days, it is able to keep a record of the amount of UV received over a certain course of time, from a single day to a month. Low energy consumption and high accuracy in estimating the UV index are salient features of this system.

  15. Assessing Doses to Interventional Radiologists Using a Personal Dosimeter Worn Over a Protective Apron

    Energy Technology Data Exchange (ETDEWEB)

    Stranden, E.; Widmark, A.; Sekse, T. (Buskerud Univ. College, Drammen (Norway))

    2008-05-15

    Background: Interventional radiologists receive significant radiation doses, and it is important to have simple methods for routine monitoring of their exposure. Purpose: To evaluate the usefulness of a dosimeter worn outside the protective apron for assessments of dose to interventional radiologists. Material and Methods: Assessments of effective dose versus dose to dosimeters worn outside the protective apron were achieved by phantom measurements. Doses outside and under the apron were assessed by phantom measurements and measurements on eight radiologists wearing two routine dosimeters for a 2-month period during ordinary working conditions. Finger doses for the same radiologists were recorded using thermoluminescent dosimeters (TLD; DXT-RAD Extremity dosimeters). Results: Typical values for the ratio between effective dose and dosimeter dose were found to be about 0.02 when the radiologist used a thyroid shield and about 0.03 without. The ratio between the dose to the dosimeter under and outside a protective apron was found to be less than 0.04. There was very good correlation between finger dose and dosimeter dose. Conclusion: A personal dosimeter worn outside a protective apron is a good screening device for dose to the eyes and fingers as well as for effective dose, even though the effective dose is grossly overestimated. Relatively high dose to the fingers and eyes remains undetected by a dosimeter worn under the apron

  16. Assessing Doses to Interventional Radiologists Using a Personal Dosimeter Worn Over a Protective Apron

    International Nuclear Information System (INIS)

    Stranden, E.; Widmark, A.; Sekse, T.

    2008-01-01

    Background: Interventional radiologists receive significant radiation doses, and it is important to have simple methods for routine monitoring of their exposure. Purpose: To evaluate the usefulness of a dosimeter worn outside the protective apron for assessments of dose to interventional radiologists. Material and Methods: Assessments of effective dose versus dose to dosimeters worn outside the protective apron were achieved by phantom measurements. Doses outside and under the apron were assessed by phantom measurements and measurements on eight radiologists wearing two routine dosimeters for a 2-month period during ordinary working conditions. Finger doses for the same radiologists were recorded using thermoluminescent dosimeters (TLD; DXT-RAD Extremity dosimeters). Results: Typical values for the ratio between effective dose and dosimeter dose were found to be about 0.02 when the radiologist used a thyroid shield and about 0.03 without. The ratio between the dose to the dosimeter under and outside a protective apron was found to be less than 0.04. There was very good correlation between finger dose and dosimeter dose. Conclusion: A personal dosimeter worn outside a protective apron is a good screening device for dose to the eyes and fingers as well as for effective dose, even though the effective dose is grossly overestimated. Relatively high dose to the fingers and eyes remains undetected by a dosimeter worn under the apron

  17. 76 FR 58537 - In the Matter of Certain Personal Data and Mobile Communications Devices and Related Software...

    Science.gov (United States)

    2011-09-21

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-710] In the Matter of Certain Personal Data and Mobile Communications Devices and Related Software; Notice of Commission Determination To... importation of certain personal data and mobile communications devices and related software. 75 FR 17434 (Apr...

  18. Personal protection against biting insects and ticks

    Directory of Open Access Journals (Sweden)

    2011-02-01

    Full Text Available Recent events with the first cases of local transmission of chikungunya and dengue fever virus in southern France by Aedes albopictus, adding to the nuisance and potential vectors that can be encountered when traveling in tropical or sub-tropical countries, has shown the value of a reflection on the Personal protection against vectors (PPAV. It is seen during an outbreak of vector-borne disease, or simply because of nuisance arthropods, that our fellow citizens try to protect themselves individually by using an arsenal of resources available on the market. Yet most of these means have been neither checked for effectiveness or safety tests, however, essential. Travellers, staff on mission or assignment, are looking for specific information on how to protect themselves or their families. Health workers had at their disposal so far indications that vary widely from one source to another. Therefore it seemed important to the Society of Travel Medicine (SMV and the French Society of Parasitology (SFP to initiate a reflection on this theme. This reflection took the form of recommendations for good practice, following the outline established by the French High Health Authority (HAS. The aim was to gather all relevant information, verified and validated and the format to be used not only by health personnel (doctors, pharmacists, nurses, but also by travel agents and individuals. This document highlights the need to take into account the risk of vector-borne diseases, some deadly, and the benefit of various methods of personal protection. The choice of methods is clearly oriented towards those whose effectiveness has been proven and potential risks assessed. The paper finally proposes two decision trees based on the transmission type (day or night and kind of stay (short or roaming, long and steady. It concerns travellers, but also expatriates, residents and nomads.

  19. Using Personal Portable Devices as Learning Tools in the English Class

    Directory of Open Access Journals (Sweden)

    Luz Edith Herrera Díaz

    2014-10-01

    Full Text Available A group of university students used a variety of personal portable devices (cellphones, tablets, laptops, and netbooks which distracted them in English class. This qualitative action research aimed to implement activities entailing the use of such devices and to learn their impact on students’ learning and the use of English in class. Thus, a series of applications was used to promote the use of these devices for the benefit of the English as a Foreign Language class. These applications included a learning management system that resembled a social network, a live interaction application, and an online dictionary. It was found that students were able to productively use these devices as learning tools plus they expressed comfort and interest in using them.

  20. Intra-building People Localisation Using Personal Bluetooth Low Energy (BLE Devices

    Directory of Open Access Journals (Sweden)

    Glebs Kuzmics

    2018-04-01

    Full Text Available This paper discusses the conceptual implementation of a system to locate people inside buildings using their personal Bluetooth® low energy device(s in situations of a crisis. Various aspects of BLE technology are covered with regard to their usage for emergency management. Legal, social, ethical and professional issues are also discussed in using this technology, especially in matters of safeguarding information privacy. The plan of the proposed system is then discussed and concluded.

  1. Knowledge and Use of Personal Protective Measures Against ...

    African Journals Online (AJOL)

    Background: Mosquito borne diseases (MBDs) are major public health problem in India. State of Delhi is endemic for dengue and other MBDs. The increasing incidence of MBDs in Delhi in recent years warrants a pro.active approach for their prevention. Knowledge and use of personal protective measures (PPMs) presents ...

  2. Examining the Efficacy of Personal Response Devices in Army Training

    Science.gov (United States)

    Hill, Angelina; Babbitt, Bea

    2013-01-01

    Benefits of personal response devices (PRDs) have been demonstrated in a variety of settings and disciplines in higher education. This study looked outside of higher education to investigate the efficacy of PRDs in an Army training course in terms of trainee performance, engagement, and satisfaction. Instructors were also surveyed to determine…

  3. Clothing, equipment and devices for personnel protection: Its selection according to occupational risks

    International Nuclear Information System (INIS)

    1989-01-01

    This Venezuelan standard establishes the selection of the type of clothing, equipment and devices for personnel protection, to be used by workers according to the occupational risk they deal with, in order to avoid or to reduce the factors that can, directly or indirectly, affect their physical integrity. For the risks not contemplated in this norm, the selection of the type of clothing, equipment and devices for personnel protection, must be done following the corresponding international standard [es

  4. X-ray face mask and bib device

    International Nuclear Information System (INIS)

    Forshee, D.J.; Moti, S.

    1984-01-01

    This invention provides an improved device for shielding and protecting a person against direct and scattered x-ray radiation to the face, head and neck to be worn on the shoulders. The device includes a radiation-shielding face mask having a lead-filled frame and a lead-containing transparent radiation-shielding lens mounted in the frame. The frame is supported upon the shoulders. A first portion of the frame extends generally inward below the chin of the person, and a second portion of the frame extends generally vertically from an inward portion of the first portion and generally rearwardly adjacent to at least one lateral side of the neck of the person

  5. Is prevention of acute pesticide poisoning effective and efficient, with Locally Adapted Personal Protective Equipment?

    DEFF Research Database (Denmark)

    Varma, Anshu; Neupane, Dinesh; Ellekilde Bonde, Jens Peter

    2016-01-01

    BACKGROUND: Farmers' risk of pesticide poisoning can be reduced with personal protective equipment but in low-income countries farmers' use of such equipment is limited. OBJECTIVE: To examine the effectiveness and efficiency of Locally Adapted Personal Protective Equipment to reduce organophosphate...... exposure among farmers. METHODS: In a crossover study, 45 male farmers from Chitwan, Nepal, were randomly allocated to work as usual applying organophosphate pesticides wearing Locally Adapted Personal Protective Equipment or Daily Practice Clothing. For seven days before each experiment, each farmer.......08;0.06]. Wearing the Locally Adapted Personal Protective Equipment versus Daily Practice Clothing gave the following results, respectively: comfort 75.6% versus 100%, sense of heat 64.4% versus 31.3%, other problems 44.4% versus 33.3%, likeability 95.6% versus 77.8%. CONCLUSION: We cannot support the expectation...

  6. BIOETHICAL SENSIBILITY OF THE LAW ON PROTECTION OF PERSONS WITH MENTAL DIFFICULTIES

    Directory of Open Access Journals (Sweden)

    Velinka Grozdanić

    2017-01-01

    Full Text Available A more and more obvious gap between the human spiritual development, which mostly stagnates, and often even regresses, and the technological development of society, which intensively and unstoppably grows, has been the initiation of numerous bioethical discussions that cover a wide range of topics, i.e. from a concern for a man and his health to a concern for nature and preservation of life in general. No matter the fact that numerous ethical discussions, which highlighted the last decade, have resulted with commonly accepted principles, several ethical issues were left without clear and unambiguous solutions. Within this context, the legal regulations expected to protect persons from unacceptable and harmful actions, but at the same time not to present an obstacle to scientific and technological development of society, have gained a special meaning. This is a significant challenge due to the fact that through statutory provisions we need to reach a balance between the freedom of scientific research and protection of a man. Although ethical dilemmas follow almost every field of human actions, bioethical contents are especially associated with the unimaginable technological achievements in medicine. Thereby, persons with mental difficulties, as one of the most vulnerable groups of patients, demand a highlighted bioethical sensibility within the meaning of humanity, understanding and enhanced awareness when ethically questionable medical procedures are applied on them, and especially when these patients are included in, sometimes even hazardous, biomedical researches. A basic protective mechanism for this category of persons in the Republic of Croatia is the Law on Protection of Persons with Mental Difficulties. The Law establishes a clear legal framework to proceed with actions designated for persons with mental difficulties, and certain legal provisions embodied within the Law could be considered a quite concrete answer to numerous ethical

  7. Personal computer versus personal computer/mobile device combination users' preclinical laboratory e-learning activity.

    Science.gov (United States)

    Kon, Haruka; Kobayashi, Hiroshi; Sakurai, Naoki; Watanabe, Kiyoshi; Yamaga, Yoshiro; Ono, Takahiro

    2017-11-01

    The aim of the present study was to clarify differences between personal computer (PC)/mobile device combination and PC-only user patterns. We analyzed access frequency and time spent on a complete denture preclinical website in order to maximize website effectiveness. Fourth-year undergraduate students (N=41) in the preclinical complete denture laboratory course were invited to participate in this survey during the final week of the course to track login data. Students accessed video demonstrations and quizzes via our e-learning site/course program, and were instructed to view online demonstrations before classes. When the course concluded, participating students filled out a questionnaire about the program, their opinions, and devices they had used to access the site. Combination user access was significantly more frequent than PC-only during supplementary learning time, indicating that students with mobile devices studied during lunch breaks and before morning classes. Most students had favorable opinions of the e-learning site, but a few combination users commented that some videos were too long and that descriptive answers were difficult on smartphones. These results imply that mobile devices' increased accessibility encouraged learning by enabling more efficient time use between classes. They also suggest that e-learning system improvements should cater to mobile device users by reducing video length and including more short-answer questions. © 2016 John Wiley & Sons Australia, Ltd.

  8. Protective device for the head of a gushing well

    Energy Technology Data Exchange (ETDEWEB)

    Kutepov, A.I.; Prokopov, O.I.

    1982-01-01

    A protective device is proposed for the head of a gushing well. It includes a housing with assembly for attachment to the pipe string. It is distinguished by the fact that in order to simplify insulation of the device at the well head and to improve its reliable operation, the housing is made in the form of sections, each of which is made in the form of a crimped sleeve with upper and lower flanges on the ends. The lower flange is equipped with a guide bushing installed inside the sleeve and clamps for attaching it in relation to the upper flange.

  9. The competent person in radiation protection: practical radiation protection for industry and research - unsealed sources

    International Nuclear Information System (INIS)

    Bruchet, H.

    2009-01-01

    The mission of the competent person in radiation protection has been broadly developed these last years to take an essential function in firm:study of working place, delimitation of regulated areas, monitoring of exposure, relations with authorities. The competent person in radiation protection must follow a training, defined by decree and shared in two parts: a theoretical part used as compulsory subjects and a practical part specific to the different sectors of activity (research, industry, medical centers, nuclear facilities) as well as the radiation use type. This volume corresponds to the practical module devoted to the industrial and research facilities concerned by the possession of management of sealed or unsealed sources. In accordance with the regulations stipulating that this module must allow to apply the theoretical knowledge to concrete situations in work. It includes eight chapters as following: radiation protection in industrial and research facilities, use of sources and associated risks, fitting out professional premises, evaluation of exposure, control of radiation protection; use of detection equipment and radioactive contamination and exposure measurement equipment, associated to methods and calculation tools; radioactive waste management; accidental or damaged situations management; methodology of working place analysis completed by the application to practical cases found in laboratories. (N.C.)

  10. Awareness and utilization of protective eye device among welders in ...

    African Journals Online (AJOL)

    Ramakantb

    was a high level of awareness of protective eye devices among the welders (367, 90.6%), being higher among arc welders compared ... each respondent in the field. The welders' ... Thermal retinal damage can also occur from near infrared ...

  11. Main radiation protection actions for medical personnel as primary responders front of an event with radiological dispersive device

    International Nuclear Information System (INIS)

    Duque, Hildanielle Ramos

    2015-01-01

    After the terrorist attack in New York, USA, in 2001, there was a worldwide concern about possible attacks using radioactive material in conventional detonators, called as Radiological Dispersal Device (RDD) or 'dirty bomb'. Several studies have been and are being made to form a global knowledge about this type of event. As until now, fortunately, there has not been an event with RDD, the Goiania Radiological Accident in Brazil, 1987, is used as a reference for decision-making. Several teams with technical experts should act in an event with RDD, but the medical staffs who respond quickly to the event must be properly protected from the harmful effects of radiation. Based on the radiological protection experts performance during the Goiania accident and the knowledge from lessons learned of many radiological accidents worldwide, this work presents an adaptation of the radiation protection actions for an event with RDD that helps a medical team as primary responders. The following aspects are presented: the problem of radioactive contamination from the explosion of the device in underground environment, the actions of the first responders and evaluation of health radiation effects. This work was based on specialized articles and papers about radiological accidents and RDD; as well as personal communication and academic information of the Institute of Radiation Protection and Dosimetry. The radiation protection actions, adapted to a terrorist attack event with RDD, have as a scenario a subway station in the capital. The main results are: the use of the basic radiation protection principle of time because there is no condition to take care of a patient keeping distance or using a shielding; the use of full appropriate protection cloths for contaminating materials ensuring the physical safety of professionals, and the medical team monitoring at the end of a medical procedure, checking for surface contamination. The main conclusion is that all medical actions

  12. Determinants of the Intention to Protect Personal Information among Facebook Users

    Directory of Open Access Journals (Sweden)

    Bum Soo Chon

    2018-02-01

    Full Text Available This study aimed to examine predictors of the intention to protect personal information on Facebook. We conducted an online survey of 679 Facebook users in the Republic of Korea. The findings of this study showed that usefulness and ease of use had significant effects on attitudes toward protection behavior. The results also revealed that risk factors (privacy risk severity and vulnerability had significant effects on protective behaviors. Based on our findings, we discussed the information protection of privacy on Facebook.

  13. MODELING OF POWER SYSTEMS AND TESTING OF RELAY PROTECTION DEVICES IN REAL AND MODEL TIME

    Directory of Open Access Journals (Sweden)

    I. V. Novash

    2017-01-01

    Full Text Available The methods of modelling of power system modes and of testing of relay protection devices with the aid the simulation complexes in real time and with the help of computer software systems that enables the simulation of virtual time scale are considered. Information input protection signals in the simulation of the virtual model time are being obtained in the computational experiment, whereas the tests of protective devices are carried out with the help of hardware and software test systems with the use of estimated input signals. Study of power system stability when modes of generating and consuming electrical equipment and conditions of devices of relay protection are being changed requires testing with the use of digital simulators in a mode of a closed loop. Herewith feedbacks between a model of the power system operating in a real time and external devices or their models must be determined (modelled. Modelling in real time and the analysis of international experience in the use of digital simulation power systems for real-time simulation (RTDS simulator have been fulfilled. Examples are given of the use of RTDS systems by foreign energy companies to test relay protection systems and control, to test the equipment and devices of automatic control, analysis of cyber security and evaluation of the operation of energy systems under different scenarios of occurrence of emergency situations. Some quantitative data on the distribution of RTDS in different countries and Russia are presented. It is noted that the leading energy universities of Russia use the real-time simulation not only to solve scientific and technical problems, but also to conduct training and laboratory classes on modelling of electric networks and anti-emergency automatic equipment with the students. In order to check serviceability of devices of relay protection without taking into account the reaction of the power system tests can be performed in an open loop mode with the

  14. Problematic radiation protective devices for X-ray diagnostics

    International Nuclear Information System (INIS)

    Beck, A.; Nanko, N.; Bruggmoser, G.; Eble, M.

    1988-01-01

    The authors report experimental test results of radiation safety glasses with a lead equivalence of 0.5 mm Pb. The glasses were tested on a phantom, with various radiation projections, for their shielding effect with regard to the eye lens. The protective effect at AP projection was 90%, which corresponds to the data given by the manufacturer. But in most cases of interventional radiology, the examiner's eyes are exposed to lateral radiation, due to the positioning of the monitor. In these cases, reflected radiation at the side of the glasses facing the eye may induce a dose to the lens that can be fourfold the dose received without wearing the glasses, so that wearing these glasses may enhance the hazard. Another protective device tested was lead-coated gloves. The manufacturer promises a protective effect of 50% at 100 kV. The experimental test data, obtained by taking into account technical characteristics of angiographic components, confirm a radiation shielding of about 20%. (orig./HP) [de

  15. The first insertion devices at SSRL - some personal recollections

    Energy Technology Data Exchange (ETDEWEB)

    Winick, H. [Stanford Linear Accelerator Center, CA (United States)

    1995-02-01

    The author recounts his experiences with insertion devices at the Stanford Synchrotron Radiation Laboratory. His first experiences with wigglers occured at the Cambridge Electron Accelerator, and was carried over to SSRL with the proposal for a six pole electromagnetic wiggler. Most modern undulators, and many wigglers are now designed around permanent magnets, and the origin of this transition at SSRL was rather fortuitous and humorous. It reflects some of the personality characteristics of Klaus Halbach.

  16. FiberNet--a new embolic protection device for carotid artery stenting.

    Science.gov (United States)

    Bauer, C; Franke, J; Bertog, S C; Woerner, V; Ghasemzadeh-Asl, S; Sievert, H

    2014-05-01

    Though distal filter protection during carotid stenting reduces the risk of cerebrovascular events, periprocedural stroke remains a risk despite their broad usage. This observation may be related to the pore size of common filters. The FiberNet distal filter system is unique by its very small pore size (40 µm) as well as its low profile and flexibility. Little data is available regarding the clinical performance and safety of this device. The aim was the evaluation of the safety of the FiberNet embolic protection system during carotid artery stenting. All consecutive patients treated with carotid stenting at our institution using the FiberNet device were systematically followed. Primary endpoint was the rate of all death and stroke within 30 days of the procedure. Carotid artery stenting using the FiberNet embolic protection system was performed in 54 patients. The procedure was technical successful in all patients. Three patients (5.5%) had a TIA. Amauosis fugax occurred in two patients (3.7%). One patient (1.9%) had a minor stroke with hemiparesis of the left arm and face which resolved completely within 48 hr after the procedure. No patient died or suffered a major stroke. The safety and feasibility of the FiberNet distal protection system appears to be at least equivalent to that reported in studies using conventional distal filter protection. Copyright © 2013 Wiley Periodicals, Inc.

  17. Electronic Systems for the Protection of Superconducting Devices in the LHC

    CERN Document Server

    Denz, R; Mess, K H

    2008-01-01

    The Large Hadron Collider LHC [1] incorporates an unprecedented amount of superconducting components: magnets, bus-bars, and current leads. Most of them require active protection in case of a transition from the superconducting to the resistive state, the so-called quench. The electronic systems ensuring the reliable quench detection and further protection of these devices have been developed and produced over the last years and are currently being put into operation

  18. Surge protective device response to steep front transient in low voltage circuit

    Energy Technology Data Exchange (ETDEWEB)

    Marcuz, J.; Binczak, S.; Bilbault, J.M. [Universite de Bourgogne, Dijon (France)], Emails: jerome.marcuz@ laposte.net, stbinc@u-bourgogne.fr, bilbault@u-bourgogne.fr; Girard, F. [ADEE Electronic, Pont de Pany (France)

    2007-07-01

    Surge propagation on cables of electrical or data lines leads to a major protection problem as the number of equipment based on solid-state circuits or microprocessors increases. Sub-microsecond components of real surge waveform has to be taken into account for a proper protection even in the case of surges caused by indirect lightning effects. The response of a model of transient voltage suppressor diode based surge protection device (SPD) to fast front transient is analytically studied, then compared to simulations, including the lines connected to the SPD and to the protected equipment. (author)

  19. A study on ship impacting a flexible crashworthy device for protecting bridge pier

    Directory of Open Access Journals (Sweden)

    Yang Liming

    2015-01-01

    Full Text Available As the accident of a vessel impacting a bridge pier will cause serious disaster, such as destroyed bridge, sinking ship and polluting environment, the technology and method to protect bridge pier from ship collision have been widely investigated recently. Due to the huge kinetic energy of large-tonnage ship and the short time duration in the collision, the studies involve impact mechanics. A developed flexible crashworthy device has been developed to protect bridges, which consists of an outer steel-periphery, an inner steel-periphery and the rubber coating SWRCs(soft elements installed between them. When the SWRC crashworthy device is installed, the collision duration under low impact force is prolonged due to its high compliance, which results in the ship having enough time to turn its navigation direction and most of the remainder kinetic energy being carried off by the turned away ship. Consequently, both impact forces on the ship and on the bridge pier decrease markedly. This is the key reason as to why the SWRC crashworthy device can avoid the destruction of both the bridge and the ship. Based on our results of theoretical studies and numerical simulations, the present paper will propose an experiment-adopted a real ship to impact a flexible crashworthy device. The collision test has been performed 12 times with different speed, carrying capacity, and impact angle of the ship. After the experiments, the ship, flexible crashworthy device and the pier are not damaged. The experiments show that the flexible crashworthy device can turn away the impact ship, so that the ship moves along the outer part of the device, which reduces the ship impact force on the bridge pier obviously. It not only protects bridges but also avoids the damage to ships.

  20. A Study on the technology of the Protective Device Application for the power Telecommunication Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Lee, B.K.; Lee, S.J.; Choi, H.Y. [Korea Electric Power Research Insitute, Taejeon (Korea, Republic of); Lee, B.H.; Jeon, D.K.; Lee, K.O.; Ahn, C.H.; Kim, S.O.; Kim, J.S. [Electrical Engineering and Science Research Center, Seoul (Korea, Republic of)

    1997-12-31

    In order to protect the power telecommunication system from surge by lightning or switching and ground potential rise, characteristics of surge are analyzed when surge strikes communication system. Surge generator which meets international standard was made and test of protective devices was carried out by using it. Counter measures against surge is established through the analysis of ground potential which varies with transient ground impedance. Also specification for installing protective devices was recommended, which is proper to apply to the field system. (author). 186 refs., 203 figs., 21 tabs.

  1. Protection of personal information in South Africa: a framework for biometric data collection security

    CSIR Research Space (South Africa)

    Mzila, Phiwa

    2016-11-01

    Full Text Available personal information. Like many other countries, South Africa, in 2013 officially approved and enacted the Protection of Personal Information Act, which gives guidelines that should be followed when processing personal information. The Act regards biometric...

  2. Fish protection at steam-electric power plants: alternative screening devices

    International Nuclear Information System (INIS)

    Cannon, J.B.

    1978-01-01

    Since the enactment of the Federal Water Pollution Control Act Amendments of 1972, very few innovations have surfaced that advance the state of intake technology for fish protection at steam-electric power plants. After careful examination of basic hydrology, hydraulics, and ecology of the source water body is completed and after a suitable location for the intake is established, the design process reduces to the development of proper screening techniques and to the provision of a means of preventing resident and migratory species from entering the intake structure. As a result of this design process, three basic fish protection concepts have evolved: fish deterrence, fish collection and removal, and fish diversion. Intake screening devices that protect fish are discussed

  3. Reference neutron radiations. Part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field

    International Nuclear Information System (INIS)

    2000-01-01

    ISO 8529 consists of the following parts, under the general title Reference neutron radiations: Part 1: Characteristics and methods of production; Part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field; Part 3: Calibration of area and personal dosimeters and determination of response as a function of energy and angle of incidence. This Part 2. of ISO 8529 takes as its starting point the neutron sources described in ISO 8529-1. It specifies the procedures to be used for realizing the calibration conditions of radiation protection devices in neutron fields produced by these calibration sources, with particular emphasis on the corrections for extraneous effects (e.g., the neutrons scattered from the walls of the calibration room). In this part of ISO 8529, particular emphasis is placed on calibrations using radionuclide sources (clauses 4 to 6) due to their widespread application, with less details given on the use of accelerator and reactor sources (8.2 and 8.3). This part of ISO 8529 then leads to ISO 8529-3 which gives conversion coefficients and the general rules and procedures for calibration

  4. Accidents, injuries and the use of personal protective equipment ...

    African Journals Online (AJOL)

    They are often neglected and their health and safety are generally overlooked. This study ... respondents had an accident at the workplace while 4% had injury, 60% had burns/scald injury while 72% had falls. In all, 6(54.5%) who ... Key words: Hospital cleaners, personal protective equipment, accidents, injuries, workplace.

  5. A privacy protection model to support personal privacy in relational databases.

    OpenAIRE

    2008-01-01

    The individual of today incessantly insists on more protection of his/her personal privacy than a few years ago. During the last few years, rapid technological advances, especially in the field of information technology, directed most attention and energy to the privacy protection of the Internet user. Research was done and is still being done covering a vast area to protect the privacy of transactions performed on the Internet. However, it was established that almost no research has been don...

  6. 78 FR 24234 - Agency Information Collection Activities; Submission for OMB Review; Comment Request; Personal...

    Science.gov (United States)

    2013-04-24

    ... for OMB Review; Comment Request; Personal Protective Equipment Standard for General Industry ACTION... Standard for General Industry,'' to the Office of Management and Budget (OMB) for review and approval for... for eyes, face, head, and extremities; protective clothing; respiratory devices; and protective...

  7. First-in-man use of a novel embolic protection device for patients undergoing transcatheter aortic valve implantation.

    Science.gov (United States)

    Naber, Christoph K; Ghanem, Alexander; Abizaid, Alexander A; Wolf, Alexander; Sinning, Jan-Malte; Werner, Nikos; Nickenig, Georg; Schmitz, Thomas; Grube, Eberhard

    2012-05-15

    We describe the first-in-human experience with a novel cerebral embolic protection device used during transcatheter aortic valve implantation (TAVI). One current challenge of TAVI is the reduction of procedural stroke. Procedural mobilisation of debris is a known source of cerebral embolisation. Mechanical protection by transient filtration of cerebral blood flow might reduce the embolic burden during TAVI. We aimed to evaluate the feasibility and safety of the Claret CE Pro™ cerebral protection device in patients undergoing TAVI. Patients scheduled for TAVI were prospectively enrolled at three centres. The Claret CE Pro™ (Claret Medical, Inc. Santa Rosa, CA, USA) cerebral protection device was placed via the right radial/brachial artery prior to TAVI and was removed after the procedure. The primary endpoint was technical success rate. Secondary endpoints encompassed procedural and 30-day stroke rates, as well as device-related complications. Deployment of the Claret CE Pro™ cerebral protection device was intended for use in 40 patients, 35 devices were implanted into the aortic arch. Technical success rate with delivery of the proximal and distal filter was 60% for the first generation device and 87% for the second-generation device. Delivery times for the first-generation device were 12.4±12.1 minutes and 4.4 ± 2.5 minutes for the second-generation device (pto the Claret CE Pro System was 19.6 ± 3.8 ml. Captured debris was documented in at least 19 of 35 implanted devices (54.3%). No procedural transient ischaemic attacks, minor strokes or major strokes occurred. Thirty-day follow-up showed one minor stroke occurring 30 days after the procedure, and two major strokes both occurring well after the patient had completed TAVI. The use of the Claret CE Pro™ system is feasible and safe. Capture of debris in more than half of the patients provides evidence for the potential to reduce the procedural cerebral embolic burden utilising this dedicated filter

  8. Second meeting of competent persons in radiation protection; Deuxiemes rencontres des personnes competentes en radioprotection

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    This conference treats the subjects interesting the competent persons in radiation protection. It is divided in four sessions. The first one concerns the regulatory bases for the action of competent persons and includes three articles, the second one is about the operational dosimetry and includes six articles, the third session is devoted to the sources and waste management and represents two texts, the last and fourth session concerns the competent person in radiation protection and gives evidence. (N.C.)

  9. Evaluating Tree Protection Devices: Effects on Growth and Survival–First-Year Results

    Science.gov (United States)

    L. R. Costello; R. H. Schmidt; Gregory A. Giusti

    1991-01-01

    The protection of seedlings from animal browsing is critical for the survival and growth of many tree species. This is particularly true in wildland areas and arid areas (McAuliffe, 1986), and oftentimes in urban areas. A variety of techniques and devices have been used to protect seedlings, from using straw stubble to milk cartons to plastic or metal screens. Recently...

  10. High‐frequency profile in adolescents and its relationship with the use of personal stereo devices

    Directory of Open Access Journals (Sweden)

    Renata Almeida Araújo Silvestre

    2016-03-01

    Conclusion: The prevalence of harmful sound habits due to the use of personal stereo devices is high in the adolescent population, but there was no correlation between exposure to high sound pressure levels through personal stereos and the high‐frequency thresholds in this population.

  11. Protection relay of phase-shifting device with thyristor switch for high voltage power transmission lines

    Science.gov (United States)

    Lachugin, V. F.; Panfilov, D. I.; Akhmetov, I. M.; Astashev, M. G.; Shevelev, A. V.

    2014-12-01

    Problems of functioning of differential current protection systems of phase shifting devices (PSD) with mechanically changed coefficient of transformation of shunt transformer are analyzed. Requirements for devices of protection of PSD with thyristor switch are formulated. Based on use of nonlinear models of series-wound and shunt transformers of PSD modes of operation of major protection during PSD, switching to zero load operation and to operation under load and during short circuit operation were studied for testing PSD with failures. Use of the principle of duplicating by devices of differential current protection (with realization of functions of breaking) of failures of separate pares of PSD with thyristor switch was substantiated. To ensure protection sensitivity to the shunt transformer winding short circuit, in particular, to a short circuit that is not implemented in the current differential protection for PSD with mechanical switch, the differential current protection reacting to the amount of primary ampere-turns of high-voltage and low-voltage winding of this transformer was designed. Studies have shown that the use of differential current cutoff instead of overcurrent protection for the shunt transformer wndings allows one to provide the sensitivity during thyristor failure with the formation of a short circuit. The results of simulation mode for the PSD with switch thyristor designed to be installed as switching point of Voskhod-Tatarskaya-Barabinsk 220 kV transmission line point out the efficiency of the developed solutions that ensure reliable functioning of the PSD.

  12. Radiation protection in nuclear medicine

    International Nuclear Information System (INIS)

    Seeburrun, V.

    2013-04-01

    Radiation protection in nuclear medicine in this project is concerned with the reduction of doses to workers, patients and members of the public. Protection of workers is achieved by adopting good personal habits, good housekeeping, proper use of personal protective devices and equipment, attend training and have continuous education. Exposure to radiation of workers and the members of the public are minimised by proper management of radioactive waste and safe transport of radioactive material. The design and shielding of a nuclear medicine department shall further provide for the protection of the worker, the patient and the general public. Protection of patient is achieved by justifying the procedure, delivering the minimum radiation dose possible to the patient while obtaining the best image quality and applying guidance levels. Special considerations shall be given to pregnant and breast-feeding patients. Quality assurance programme through image quality, radiopharmaceutical quality and patient records on nuclear medicine procedures shall provide assurance to the patient. (au)

  13. Method of and device for querying of protected structured data

    NARCIS (Netherlands)

    Jonker, Willem; Brinkman, Richard; Doumen, J.M.; Schoenmakers, Berry

    2005-01-01

    Method of and device for querying of protected data structured in the form of a tree. A corresponding tree of node polynomials is constructed such that each node polynomial evaluates to zero for an input equal to an identifier assigned to a node name occurring in a branch of the data tree starting

  14. Method of and device for querying of protected structured data

    NARCIS (Netherlands)

    Brinkman, Richard; Doumen, J.M.; Jonker, Willem; Schoenmakers, B.

    Method of and device for querying of protected data structured in the form of a tree. A corresponding tree of node polynomials is constructed such that each node polynomial evaluates to zero for an input equal to an identifier assigned to a node name occurring in a branch of the data tree starting

  15. Person expert in radiation protection: changing profiles

    International Nuclear Information System (INIS)

    Anon.

    2015-01-01

    In all French enterprises producing or using ionizing radiations, a person is in charge of the protection of workers against radiations: the expert in radiation protection (PCR). The education and training of this profession has been recently reformed, and its status will evolve by 2018 with a transposition of a European directive. While indicating the six main missions of PCRs (risk assessment, definition of protection measures, zoning optimisation, training of exposed workers, dosimetry follow-up, periodic controls), this article comments the current professional profile of PCRs who can be technicians, engineers as well as researchers. It also outlines aspects of the reform which do not satisfy PCRs' needs. A second article reports how PCRs perceive their mission on a daily basis, which obstacles they face, how they are organised to communicate between them and not to be isolated (a map of PCR regional networks is provided with indications of the number of members and of the main actions), and how the IRSN helps them. A third article evokes the content of a new standard (NF C 15-160) which defines the requirements for X ray generating installations, and the related theoretical and practical training proposed by the IRSN

  16. On the Protection of Personal Data in the Access Control System

    Directory of Open Access Journals (Sweden)

    A. P. Durakovskiy

    2012-03-01

    Full Text Available The aim is to prove the qualification system of access control systems (ACS as an information system for personal data (ISPDn. Applications: systems of physical protection of facilities.

  17. Improving 200 MW NDHR reactor protection system with GAL devices

    International Nuclear Information System (INIS)

    Shi Mingde; Li Duo; Xie Zhengguo

    1999-01-01

    The emergence of General Array Logic (GAL), a fairly new type of logic devices with the characteristics of user-definable logic functions, have led to a revolutionary change in the design of logical circuits. The improvements of the reactor protection system for the 200 MW nuclear district heating reactor (NDHR) using GAL are covered

  18. Protection of persons occupationally exposed to radiation and of patients

    International Nuclear Information System (INIS)

    Stieve, F.E.

    1976-01-01

    The experiences of the last ten years have shown that the measures of the First Radiation Protection Ordinance generally proved to be sufficient for the protection of the employed or of the patients. They had to be amended in so far as the exposure to radiation for those occupationally exposed can be reduced. This results in changes to the regulations so that certain groups of persons can also be effectively controlled. The recognition that medical supervision for radiation protection reasons is reasonable only if exposure has occurred should be additionally utilized in the regulations if the Euratom standards make this possible. The protection of patients attains some new rules which can be derived from handling and from therapeutical use. In this case too experience resulted in a more reasonable application of ionizing radiation and radioactive materials than was expected when the First Radiation Protection Ordinance was issued. (orig.) [de

  19. Non-technical Issues in Design and Development of Personal Portable Devices.

    Science.gov (United States)

    Lhotska, Lenka; Cheshire, Paul; Pharow, Peter; Macku, David

    2016-01-01

    Mobile technologies are constantly evolving and with the development of Internet of Things we can expect continuous increase of various applications. Mobile technologies have undeniable opportunities to play an important role in health services. Concerning purely technical aspects, almost every problem can be solved. However, there are still many unsolved and unclear issues related with ethics and governance mechanisms for mobile phone applications. These issues are even more critical in medical and health care applications of mobile technologies. This paper tries to analyse ethical, and privacy-related challenges that may occur when introducing Personal Portable Devices (PPD) to collect and record personal health data in health care and welfare environment.

  20. Personal protection during resuscitation of casualties contaminated with chemical or biological warfare agents--a survey of medical first responders.

    Science.gov (United States)

    Brinker, Andrea; Prior, Kate; Schumacher, Jan

    2009-01-01

    The threat of mass casualties caused by an unconventional terrorist attack is a challenge for the public health system, with special implications for emergency medicine, anesthesia, and intensive care. Advanced life support of patients injured by chemical or biological warfare agents requires an adequate level of personal protection. The aim of this study was to evaluate the personal protection knowledge of emergency physicians and anesthetists who would be at the frontline of the initial health response to a chemical/biological warfare agent incident. After institutional review board approval, knowledge of personal protection measures among emergency medicine (n = 28) and anesthetics (n = 47) specialty registrars in the South Thames Region of the United Kingdom was surveyed using a standardized questionnaire. Participants were asked for the recommended level of personal protection if a chemical/biological warfare agent(s) casualty required advanced life support in the designated hospital resuscitation area. The best awareness within both groups was regarding severe acute respiratory syndrome, and fair knowledge was found regarding anthrax, plague, Ebola, and smallpox. In both groups, knowledge about personal protection requirements against chemical warfare agents was limited. Knowledge about personal protection measures for biological agents was acceptable, but was limited for chemical warfare agents. The results highlight the need to improve training and education regarding personal protection measures for medical first receivers.

  1. Corrosion and corrosion protection of support structures for offshore wind energy devices (OWEA)

    Energy Technology Data Exchange (ETDEWEB)

    Momber, A. [Muehlhan AG, Schlinckstrasse 3, D-21107 Hamburg (Germany)

    2011-05-15

    The paper provides a review about the corrosion and corrosion protection of offshore wind energy devices (OWEA). Firstly, special features resulting from location and operation of OWEA are being discussed. Secondly, types of corrosion and corrosion phenomena are summarized in a systematic way. Finally, practical solutions to the corrosion protection of OWEA, including steel allowances, cathodic protection and coatings and linings, are discussed. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  2. Electrostatic Properties of Selected Personal Protective Equipment Regarding Explosion Hazard

    Directory of Open Access Journals (Sweden)

    Marcin Jachowicz

    2013-01-01

    Full Text Available In industries such as the mining, petrochemistry or power industries, personal protective equipment is often used in explosive atmospheres. What causes the occurrence of explosive hazards is ever-present in the work environment they include, electrostatic phenomena as well as the build-up of electrical charges on the surface of the protective equipment used. This paper presents the results of studies which were aimed at determining the fundamental electrostatic parameters of protective helmets as well as eye and face protection, surface resistance and the voltage of electrostatic fields. Examinations on the typical structure of the above mentioned equipment was conducted including the variable values of ambient humidity, which can occur in the working environment and with the use of various types of materials used to generate a charge. The adopted methods and testing equipment have been presented. Using the current, general requirements regarding the electrostatic properties of materials, the examined helmets and eye protection were assessed for their use in explosive atmospheres.

  3. Tracking down a solution: exploring the acceptability and value of wearable GPS devices for older persons, individuals with a disability and their support persons.

    Science.gov (United States)

    Williamson, Brittany; Aplin, Tammy; de Jonge, Desleigh; Goyne, Matthew

    2017-11-01

    To explore the acceptability and value of three wearable GPS devices for older persons and individuals with a disability and safety concerns when accessing the community. This pilot study explored six wearers' and their support persons' experience of using three different wearable GPS devices (a pendant, watch, and mini GPS phone), each for a two-week period. Participants identified safety as the main value of using a wearable GPS device. The acceptability and value of these devices was strongly influenced by device features, ease of use, cost, appearance, the reliability of the GPS coordinates, the wearer's health condition and the users familiarity with technology. Overall, participants indicated that they preferred the pendant. Wearable GPS devices are potentially useful in providing individuals who have safety concerns with reassurance and access to assistance as required. To ensure successful utilization, future device design and device selection should consider the user's familiarity with technology and their health condition. This study also revealed that not all wearable GPS devices provide continuous location tracking. It is therefore critical to ensure that the device's location tracking functions address the wearer's requirements and reason for using the device. Implications for Rehabilitation The acceptability and usability of wearable GPS devices is strongly influenced by the device features, ease of use, cost, appearance, the reliability of the device to provide accurate and timely GPS coordinates, as well as the health condition of the wearer and their familiarity with technology. Wearable GPS devices need to be simple to use and support and training is essential to ensure they are successfully utilized. Not all wearable GPS devices provide continuous location tracking and accuracy of location is impacted by line of sight to satellites. Therefore, care needs to be taken when choosing a suitable device, to ensure that the device's location tracking

  4. Impact of Different Personal Protective Clothing on Wildland Firefighters' Physiological Strain

    OpenAIRE

    Carballo-Leyenda, Belén; Villa, José G.; López-Satué, Jorge; Rodríguez-Marroyo, Jose A.

    2017-01-01

    Wildfire firefighting is an extremely demanding occupation performed under hot environment. The use of personal protective clothing (PPC) is needed to protect subjects from the thermal exposure. However, the additional use of PPC may increase the wildland firefighters' physiological strain, and consequently limit their performance. The aim of this study was to analyze the effect of four different PPC on the physiological strain of wildland firefighters under moderate conditions (30?C and 30% ...

  5. Use of personal radiation protection tools and individual dosimetric monitoring in a sample of interventional cardiologists in France, 2005-2009

    International Nuclear Information System (INIS)

    Jacob, S.; Bertrand, A.; Laurier, D.; Bernier, M.O.; Scanff, P.

    2014-01-01

    Interventional cardiologists (ICs) are repeatedly exposed to scattered ionising radiation during the cardiac procedures they perform, and radiation protection is an important issue for these medical professionals. The use of radiation protection tools is particularly relevant to this population. SISERI (Systeme d'Information de la Surveillance de l'Exposition aux Rayonnement Ionisants, that is, an information system for monitoring exposure to ionising radiation) is a register that stores personal dosimeter readings for dosimetric monitoring. This paper, based on data for a sample of French ICs from the O'CLOC epidemiological study, aims to provide an overview of the use of radiation protection equipment and dosimetric devices reported by ICs in a specific questionnaire as well as the dosimetric information found in the SISERI database for this population. Material and Methods - Annual information on interventional cardiology activity for the period from 01/01/2005 to 31/12/2009 was collected in an occupational questionnaire. ICs were asked to report the frequency in which they used individual dosimeter and radiation protection tools (lead apron, thyroid shield, eye-wear or face shield, ceiling-suspended shield) as follows: never (0% of the time), occasionally ( 50%), always (100%). We retrieved their medical radiation exposure information (monitored status and monthly effective doses) from the SISERI database for the period 2005-2009. Results - Information for 132 ICs (mean age in 2005 = 46 ± 7 years) was available. All ICs reported routine use of lead aprons, in contrast to their occasional use of lead eye-wear or face shields. During the study period, 49% reported systematic use of personal dosimeters, and 21% more regular use. On the other hand, 18% never used a dosimeter during this period. The SISTERI database included 92% of our population, 73% of whom had complete annual dose monitoring in SISERI (corresponding to at least 11 months per year of recorded

  6. Device controllers using an industrial personal computer of the PF 2.5-GeV Electron Linac at KEK

    International Nuclear Information System (INIS)

    Otake, Yuji; Yokota, Mitsuhiro; Kakihara, Kazuhisa; Ogawa, Yujiro; Ohsawa, Satoshi; Shidara, Tetsuo; Nakahara, Kazuo

    1992-01-01

    Device controllers for electron guns and slits using an industrial personal computer have been designed and installed in the Photon Factory 2.5-GeV Electron Linac at KEK. The design concept of the controllers is to realize a reliable system and good productivity of hardware and software by using an industrial personal computer and a programmable sequence controller. The device controllers have been working reliably for several years. (author)

  7. 3D printing of a wearable personalized oral delivery device: A first-in-human study

    Science.gov (United States)

    Brambilla, Davide

    2018-01-01

    Despite the burgeoning interest in three-dimensional (3D) printing for the manufacture of customizable oral dosage formulations, a U.S. Food and Drug Administration–approved tablet notwithstanding, the full potential of 3D printing in pharmaceutical sciences has not been realized. In particular, 3D-printed drug-eluting devices offer the possibility for personalization in terms of shape, size, and architecture, but their clinical applications have remained relatively unexplored. We used 3D printing to manufacture a tailored oral drug delivery device with customizable design and tunable release rates in the form of a mouthguard and, subsequently, evaluated the performance of this system in the native setting in a first-in-human study. Our proof-of-concept work demonstrates the immense potential of 3D printing as a platform for the development and translation of next-generation drug delivery devices for personalized therapy. PMID:29750201

  8. Research and development to protect soldiers from landmines and improvised explosive devices

    CSIR Research Space (South Africa)

    Ahmed, R

    2015-10-01

    Full Text Available Landmines and Improvised Explosive Devices (IEDs) remain a major threat for military vehicles, their occupants and other assets. It is thus imperative that traditional methods of protection need to be adapted or new technologies developed....

  9. Loose-Lipped Mobile Device Intelligent Personal Assistants: A Discussion of Information Gleaned from Siri on Locked iOS Devices.

    Science.gov (United States)

    Horsman, Graeme

    2018-04-23

    The forensic analysis of mobile handsets is becoming a more prominent factor in many criminal investigations. Despite such devices frequently storing relevant evidential content to support an investigation, accessing this information is becoming an increasingly difficult task due to enhanced effective security features. Where access to a device's resident data is not possible via traditional mobile forensic methods, in some cases it may still be possible to extract user information via queries made to an installed intelligent personal assistant. This article presents an evaluation of the information which is retrievable from Apple's Siri when interacted with on a locked iOS device running iOS 11.2.5 (the latest at the time of testing). The testing of verbal commands designed to elicit a response from Siri demonstrate the ability to recover call log, SMS, Contacts, Apple Maps, Calendar, and device information which may support any further investigation. © 2018 American Academy of Forensic Sciences.

  10. The use of active personal dosemeters as a personal monitoring device: Comparison with TL dosimetry

    International Nuclear Information System (INIS)

    Boziari, A.; Koukorava, C.; Carinou, E.; Hourdakis, C. J.; Kamenopoulou, V.

    2011-01-01

    The use of active personal dosemeters (APDs) not only as a warning device but also, in some cases, as an official and hence stand-alone dosemeter is rapidly increasing. A comparison in terms of dose, energy and angle dependence, among different types of APD and a routinely used whole-body thermoluminescence dosemeter (TLD) has been performed. Significant differences were found between the TLD readings and mainly some not commonly used APDs. The importance of choosing the best adapted APD according to the radiation field characteristics is pointed out. (authors)

  11. WS-010: EPR-First Responders: Personal monitoring techniques and protective clothing

    International Nuclear Information System (INIS)

    2011-01-01

    The purpose of this working session is that the participant can apply their knowledge in relation to the personal monitoring techniques and protective clothing. They have to know the use of the radiation measurement instrumentation available in each region

  12. Intercomparison of radiation protection protection devices in a high-energy stray neutron field. Part III: Instrument response

    Czech Academy of Sciences Publication Activity Database

    Silari, M.; Agosteo, S.; Beck, P.; Bedogni, R.; Cale, E.; Caresana, M.; Domingo, C.; Donadille, L.; Dubourg, N.; Esposito, A.; Fehrenbacher, G.; Fernández, F.; Ferrarini, M.; Fiechtner, A.; Fuchs, A.; García, M. J.; Golnik, N.; Gutermuth, F.; Khurana, S.; Klages, T.; Latocha, M.; Mares, V.; Mayer, S.; Radon, T.; Reithmeier, H.; Rollet, S.; Roos, H.; Rühm, W.; Sandri, S.; Schardt, D.; Simmer, G.; Spurný, František; Trompier, F.; Villa-Grasa, C.; Weitzenegger, E.; Wiegel, B.; Wielunski, M.; Wissmann, F.; Zechner, A.; Zielczyński, M.

    2009-01-01

    Roč. 44, 7-8 (2009), s. 673-691 ISSN 1350-4487 R&D Projects: GA AV ČR IAA100480902 Institutional research plan: CEZ:AV0Z10480505 Keywords : radiation protection devices * radiation field * detectors * dosemeters Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 0.973, year: 2009

  13. Evaluation of Personal Chemical Vapor Protection for Patrol and Tactical Law Enforcement

    National Research Council Canada - National Science Library

    Fedele, Paul D; Lake, William L; Arca, Victor J; Marshall, Stephen M; Mitchell, David B

    2002-01-01

    In Domestic Preparedness efforts, the US Army Soldier and Biological Chemical Command and the Maryland State Police, have evaluated personal chemical protective systems for use in patrol and tactical...

  14. Study to the current protection of personal data in the educational sector in Indonesia

    Science.gov (United States)

    Rosmaini, E.; Kusumasari, T. F.; Lubis, M.; Lubis, A. R.

    2018-03-01

    This study examines how legal expert interpret UU ITE to protect personal data based on privacy principle by using content analysis. This act has importance in order to govern the process of collection, use, transfer, disclose and store personal data for profit or other commercial purposes. By recognizing both the right of individual for privacy and the need of organization to utilize the customer data, the Act, which was amended by Parliament at October, 27th 2016 have critical role for protection guideline in Indonesia. Increasingly, with the use of advanced technology, data protection became one of the main issues on various sectors, especially in the educational sector. Educational institutions require large amount of personal data to run their business process to support learning, teaching, research and administration process. It involves wide range of personal data from institution, agencies, colleges, lecturers, students and parents, which might consist of several sensitive and confidential data such as historical, health, financial, academic and experience background. Underestimating and ignoring these issues can lead to disaster such as blackmailing, stalking, bullying or improper use of personal data. In aggregation, they might deliver huge loss to institution either financially or trust. Thus, this study analyse the privacy principle of UU ITE through 21 coders from legal expert to obtain more understanding of appropriate approach to implement privacy policy in the educational sector.

  15. Experimental Evaluation of the Effectiveness Offered by Different Types of Personal Protective Clothing Against Nanoaerosols

    Science.gov (United States)

    Domat, M.; Pla, J.; Cadavid-Rodríguez, M. C.; Fito, C.

    2017-06-01

    The rapid expansion of nanotechnology is outpacing health and safety recommendations for engineered nanomaterials. Thus, there is a lack of information about the effects that nanomaterials can induce in the human health. Nevertheless, workers in nanotechnology-related industries are potentially at risk of being exposed to nanomaterials. Therefore, there is a need of characterize the behaviour of personal protective equipment against penetration nanoparticles, in order to provide an adequate protection to the workers. In this study, the efficiency of several protective dermal equipment against water-based NaCl aerosol was evaluated. For this purpose, different protective clothing and gloves were selected to carry out the assays, simulating typical use conditions of protective equipment under occupational settings. Results obtained exposed that the level of protection offered by the distinct types of personal protective coveralls depended not only on the fabric, but also on their fitting to the body of the subject. On the other hand, the efficiency of the protective gloves was set in the range from 95% to 99%, depending on the thickness and the type of material.

  16. Respiratory protective device design using control system techniques

    Science.gov (United States)

    Burgess, W. A.; Yankovich, D.

    1972-01-01

    The feasibility of a control system analysis approach to provide a design base for respiratory protective devices is considered. A system design approach requires that all functions and components of the system be mathematically identified in a model of the RPD. The mathematical notations describe the operation of the components as closely as possible. The individual component mathematical descriptions are then combined to describe the complete RPD. Finally, analysis of the mathematical notation by control system theory is used to derive compensating component values that force the system to operate in a stable and predictable manner.

  17. Composing Interactive Dance Pieces for the MotionComposer, a device for Persons with Disabilities

    OpenAIRE

    Bergsland, Andreas; Wechsler, Robert

    2015-01-01

    The authors have developed a new hardware/software device for persons with disabilities (the MotionComposer), and in the process created a number of interactive dance pieces for non- disabled professional dancers. The paper briefly describes the hardware and motion tracking software of the device before going into more detail concerning the mapping strategies and sound design applied to three interactive dance pieces. The paper concludes by discussing a particular philosophy championing trans...

  18. A novel mechanical design of broken rope protection device for enhancing the safety performances of overhead manned equipment in coal mine

    Directory of Open Access Journals (Sweden)

    Xiaoguang Zhang

    2015-08-01

    Full Text Available A novel mechanical design of the broken rope protection device is proposed to enhance the safety performances of the overhead manned equipment. According to the operating characteristics and functional requirements of the overhead manned equipment, a three-dimensional mechanical model of the broken rope protection device was redesigned. Based on the known parameters of the mechanical model, the stress and strength of the main components are readjusted using the statics characteristics of finite element analysis. To ensure the reliability of the control system of the broken rope protection device, the process of people’s falling, the response performance of the tension sensor, and the signal extraction of the broken rope are analyzed under different loading and unloading speeds. The working principle of the broken rope protection device is expounded in detail. The experimental results showed that better effect is obtained by the new broken rope protection device, which is characterized by good durability, low investment, and high reliability.

  19. Role and missions of the person competent in radiation protection (PCR)

    International Nuclear Information System (INIS)

    Abadia-Benoist, Genevieve; Basile, Sandy; Gauron, Christine; Guillemy, Nathalie; Moureaux, Patrick; Billarand, Yann; Rannou, Alain; Scanff, Pascale; Vidal, Jean-Pierre

    2014-01-01

    Radiation protection is a hot topic and has been the matter of debates between the French national institute of research and safety (INRS) and the French institute of radiation protection and nuclear safety (IRSN). It has been also the main topic of a joint IRSN/INRS workshop held in 2013 about the use of dosimetric data. This paper presents the joint position of both institutes with regards to the key-role, status and missions of the person competent in radiation protection (PCR) in the domain of risk prevention and access to dosimetric data. It presents also some possible measures of evolution of this occupation

  20. Filtration of nanoparticles - Application to respiratory protecting devices

    International Nuclear Information System (INIS)

    Brochot, C.

    2012-01-01

    This study aims to determine how the respiratory protective devices (RPD), whose performances are qualified for particles above 100 nm, are effective for nanoparticles. Indeed, if the use of a collective filtration is inadequate, wearing a RPD is the last protection recommended. A literature review showed that no research concerned the effectiveness of half-masks for nanoparticles. The test bench ETNA has been sized and built to overcome these lacks. Two half masks were tested according to different configurations: constant flow rate and cyclic flow rate (average flow of 84 L /min), particle size (from 5 to 100 nm), positions of the mask (sealed, usual, or with calibrated leaks). The results show that, since the RPD contain high efficiency filter media (without charged fibers) for the most penetrating particle size (100 nm - 300 nm), the RPD is more efficient for nanoparticles. Furthermore, the results obtained in the presence of actual and calibrated leaks, highlighted the importance of face seal leakages in determining the performance of RPD. A model for calculating the protection factor was established based on the balance between the airflow through the filter and the leak. This model was validated using measurements obtained in the presence of calibrated leaks, and applied for the analysis of our results in usual position. (author)

  1. Personal Portable Devices in the Light of the Internet of Things.

    Science.gov (United States)

    Lhotska, Lenka; Stechova, Katerina; Pharow, Peter

    2017-01-01

    Personal portable devices have already gained their position in health services. However, mobile technologies and Internet of Things open new areas of applications. The possibility to collect many data types continuously over long time intervals brings various questions that must be answered in the design process. We also discuss briefly the role of the user. We illustrate the complexity of the field by a case study of diabetes management.

  2. Protecting Personal Information in the Era of Identity Theft: Just how Safe is Our Personal Information from Identity Thieves?

    Directory of Open Access Journals (Sweden)

    Fawzia Cassim

    2015-07-01

    Full Text Available Identity theft has become one of the fastest growing white collar crimes in the world. It occurs when an individual's personal information such as inter alia his or her name, date of birth or credit card details is used by another individual to commit identity fraud. Identity theft can be committed via physical means or online. The increased use of the Internet for business and financial transactions, social networking and the storage of personal information has facilitated the work of identity thieves. Identity theft has an impact on the personal finances and emotional well-being of victims, and on the financial institutions and economies of countries. It presents challenges for law enforcement agencies and governments worldwide. This article examines how identity thieves use the personal information of individuals to commit identity fraud and theft, and looks at legislative solutions introduced in South Africa, the United States of America, the United Kingdom and India to combat identity theft crimes. The article examines measures introduced by the respective governments in these countries to counteract such crimes. Finally, the article will propose a way forward to counteract such crimes in the future. The study reveals that identity theft is a growing and evolving problem that requires a multi-faceted and multi-disciplinary approach by law enforcement agencies, businesses, individuals and collaboration between countries. It is advocated that businesses and institutions should take measures to protect personal information better and that individuals should be educated about their rights, and be vigilant and protect their personal information offline and in cyberspace.

  3. Transcranial Doppler monitoring during stenting of the carotid bifurcation: evaluation of two different distal protection devices in preventing embolization.

    Science.gov (United States)

    Rubartelli, Paolo; Brusa, Giulia; Arrigo, Alessandro; Abbadessa, Francesco; Giachero, Corinna; Vischi, Massimo; Ricca, Maria Maddalena; Ottonello, Gian Andrea

    2006-08-01

    To compare the efficacy of 2 emboli protection devices in preventing embolization during carotid artery stenting (CAS). The GuardWire distal occlusion system (n=19) and the distal FilterWire EX (n=12) were compared in 31 consecutive patients (24 men; mean age 71+/-10 years) monitored with transcranial Doppler for microembolic signals before, during, and after CAS. The choice of the protection device was based on availability and on the patency of the contralateral carotid artery. The baseline characteristics were similar in the patients treated under protection from either device. Placement and retrieval of the protection device, stenting, and postdilation were technically successful in all patients. Two patients suffered a transient ischemic attack shortly after the procedure; no other adverse cardiovascular events occurred at 30 days. Compared to the GuardWire, the use of the FilterWire was associated with more microembolic signals during stent deployment (77.4+/-33.5 versus 1.07+/-1.94, pprotection device (21.4+/-15.4 versus 10.9+/-8.3, p=0.051). Consequently, the total amount of microembolic signals during the procedure was higher when the filter device was employed (183.0+/-42.1 versus 31.7+/-12.0, p<0.0001). The distal occlusion device appears to be more effective than the filter in reducing distal embolization detected by transcranial Doppler monitoring.

  4. Image-based surveillance and security systems using personal computers for device aiming and digital image comparison

    International Nuclear Information System (INIS)

    Quiett, S.; Axtell, L.H.

    1987-01-01

    A detection-type security system using enhanced capability cameras or other imaging devices can aid in maintaining security from long distance and/or for large areas. To do so requires that the imaging device(s) be repeatedly and accurately positioned so that no areas are overlooked. Digital control using personal computers is the simplest method of achieving positional accuracy. The monitoring of large areas and/or a large number of areas also requires that a substantial quantity of visual information be catalogued and evaluated for potential security problems. While security personnel alone are typically used for such monitoring, as the quantity of visual information increases, the likelihood that potential security threats will be missed also increases. The ability of an image-based security system to detect potential security problems can be further increased with the use of selected image processing techniques. Utilizing personal computers for both imaging device position control as well as image processing, surveillance of large areas can be performed by a limited number of individuals with a high level of system confidence

  5. Seventh meeting of radiation protection skilled persons

    International Nuclear Information System (INIS)

    Juhel, Th.; Briandchamplong, J.; Gambini, D.J.; Ammerich, M.; Aubert, B.; Barbey, P.; Biau, A.; Bruchet, H.; Capelle, M.H.; Flon, E.; Gauron, Ch.; Gravelotte, D.; Guerin, Ch.; Le Denmat, D.; Lemoine, Th.; Lombard, J.; Lucas, St.; Menechal, Ph.; Mignien, S.; Million, M.; Mozziconacci, J.G.; Prevot, S.; Radecki, J.J.; Rigaud, S.; Taillandier, P.; Timbert, M.; Vidal, J.P.; Bardelay, Ch.; Lahaye, Th.; Balduyck, S.; Chasson, E.; Rehel, J.L.; Chatellier, Ch.; Barret, Ch.; Guersen, J.; Degrange, J.P.; Sevestre, B.; Lahaye, Th.; Rodde, S.; Marchal, C.; Lefaure, Ch.; Bouk'il, H.; Gneiting, M.; Auboiroux, B.; Riedel, A.; Feuardent, J.; Scanff, P.; Bof, M.; Lochard, J.; Godet, J.L.

    2011-01-01

    This document gathers the slides of the available presentations given during these conference days. Twenty-three presentations out of 25 are assembled in the document and deal with: 1 - the evolution of workers' international protection rules against ionizing radiation risks (C. Bardelay); 2 - presentation of the report of the working group on radiation protection (P. Barbey); 3 - position of the French nuclear safety authority and of the labor general direction about the position of permanent expert groups in radiation protection concerning the expected evolutions in the occupation and training of radioprotection skilled persons (RSP), (T. Lahaye); 4 - experience feedback: RSP in surgery operating theater - a sometimes delicate intervention (S. Balduyck); 5 - workplace analysis in dental surgery: constraints and specificities (D. Le Denmat); 6 - workplace analysis: tritium atmospheric contamination (S. Rigaud); 7 - revision of the NFC 15-160 standard relative to radiology facilities (J.L. Rehel); 8 - example of area tele-dosimetry usage - the Pitie Salpetriere hospital experiment (C. Chatellier and C. Barret); 9 - contribution of radio-attenuation lead gloves in interventional radiology (J. Guersen); 10 - zoning in the medical domain: encountered problems typology and evaluation of possible solutions (Degrange, J.P.); 11 - management of used sealed sources distributed by the CEA and CISBIO (B. Sevestre); 12 - how to perform a measurement in radiation protection - how about measurement uncertainty (M. Ammerich); 13 - national campaign of control about the application of workers radiation protection rules (T. Lahaye); 14 - transparency and inspection approach in local nuclear applications: gamma-graphy, research, nuclear medicine, interventional radiography and radiotherapy (S. Rodde and C. Marchal); 15 - local/regional networks of RSPs and radiation protection actors: 2008 audit results and recent evolutions (C. Lefaure); 16 - role and missions of the external RSP

  6. Person factors and work environments of workers who use mobility devices.

    Science.gov (United States)

    Gray, David B; Morgan, Kerri A; Gottlieb, Meghan; Hollingsworth, Holly H

    2014-01-01

    Nearly 25% of people with mobility impairments and limitations who are of working age are employed, yet few studies have examined their perspectives on their jobs or work environments required to complete job tasks. The purpose of this study was to describe the factors that contribute to successful employment for those who use mobility devices. A convenience sample of 132 workers who use power wheelchairs, manual wheelchairs, canes, crutches or walkers. Participants completed an online version of the Mobility Device User Work Survey (MWS). A multivariate analysis and a two-step multiple linear regression analysis were used. Study participants had few secondary health conditions that influenced their work. Employee satisfactoriness to their employers was high. Accessibility of worksites was high. Assistive technologies were inexpensive, and personal assistance was used infrequently and usually was unpaid. Co-worker communications were very positive. Flexible work rules and supportive managers were highly valued. Job satisfaction positively correlated with accessibility, work tasks, co-worker communication and work support. The description of work environments of successfully employed mobility device users can provide some useful guidance to employers, vocational rehabilitation (VR) counselors and unemployed mobility device users to balance employee abilities and preferences with the needs of employers.

  7. Rapid, low cost prototyping of transdermal devices for personal healthcare monitoring

    Directory of Open Access Journals (Sweden)

    Sanjiv Sharma

    2017-04-01

    Full Text Available The next generation of devices for personal healthcare monitoring will comprise molecular sensors to monitor analytes of interest in the skin compartment. Transdermal devices based on microneedles offer an excellent opportunity to explore the dynamics of molecular markers in the interstitial fluid, however good acceptability of these next generation devices will require several technical problems associated with current commercially available wearable sensors to be overcome. These particularly include reliability, comfort and cost. An essential pre-requisite for transdermal molecular sensing devices is that they can be fabricated using scalable technologies which are cost effective.We present here a minimally invasive microneedle array as a continuous monitoring platform technology. Method for scalable fabrication of these structures is presented. The microneedle arrays were characterised mechanically and were shown to penetrate human skin under moderate thumb pressure. They were then functionalised and evaluated as glucose, lactate and theophylline biosensors. The results suggest that this technology can be employed in the measurement of metabolites, therapeutic drugs and biomarkers and could have an important role to play in the management of chronic diseases. Keywords: Microneedles, Minimally invasive sensors, Continuous glucose monitoring (CGM, Continuous lactate monitoring (CLM, Interstitial therapeutic drug monitoring (iTDM

  8. Using a Personal Device to Strengthen Password Authentication from an Untrusted Computer

    Science.gov (United States)

    Mannan, Mohammad; van Oorschot, P. C.

    Keylogging and phishing attacks can extract user identity and sensitive account information for unauthorized access to users' financial accounts. Most existing or proposed solutions are vulnerable to session hijacking attacks. We propose a simple approach to counter these attacks, which cryptographically separates a user's long-term secret input from (typically untrusted) client PCs; a client PC performs most computations but has access only to temporary secrets. The user's long-term secret (typically short and low-entropy) is input through an independent personal trusted device such as a cellphone. The personal device provides a user's long-term secrets to a client PC only after encrypting the secrets using a pre-installed, "correct" public key of a remote service (the intended recipient of the secrets). The proposed protocol (MP-Auth) realizes such an approach, and is intended to safeguard passwords from keyloggers, other malware (including rootkits), phishing attacks and pharming, as well as to provide transaction security to foil session hijacking. We report on a prototype implementation of MP-Auth, and provide a comparison of web authentication techniques that use an additional factor of authentication (e.g. a cellphone, PDA or hardware token).

  9. Effects of sterilization on the mechanical properties of poly(methyl methacrylate) based personalized medical devices.

    Science.gov (United States)

    Münker, T J A G; van de Vijfeijken, S E C M; Mulder, C S; Vespasiano, V; Becking, A G; Kleverlaan, C J; Becking, A G; Dubois, L; Karssemakers, L H E; Milstein, D M J; van de Vijfeijken, S E C M; Depauw, P R A M; Hoefnagels, F W A; Vandertop, W P; Kleverlaan, C J; Münker, T J A G; Maal, T J J; Nout, E; Riool, M; Zaat, S A J

    2018-05-01

    Nowadays, personalized medical devices are frequently used for patients. Due to the manufacturing procedure sterilization is required. How different sterilization methods affect the mechanical behavior of these devices is largely unknown. Three poly(methyl methacrylate) (PMMA) based materials (Vertex Self-Curing, Palacos R+G, and NextDent C&B MFH) were sterilized with different sterilization methods: ethylene oxide, hydrogen peroxide gas plasma, autoclavation, and γ-irradiation. Mechanical properties were determined by testing the flexural strength, flexural modulus, fracture toughness, and impact strength. The flexural strength of all materials was significantly higher after γ-irradiation compared to the control and other sterilization methods, as tested in a wet environment. NextDent C&B MFH showed the highest flexural and impact strength, Palacos R+G showed the highest maximum stress intensity factor and total fracture work. Autoclave sterilization is not suitable for the sterilization of PMMA-based materials. Ethylene oxide, hydrogen peroxide gas plasma, and γ-irradiation appear to be suitable techniques to sterilize PMMA-based personalized medical devices. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  10. Fifth meeting of persons competent in radiation protection

    International Nuclear Information System (INIS)

    2007-01-01

    During this meeting will successively be approached: the statutory frame, the practical guide for the realization of the dosimetry studies of work stations presenting a risk of exposure to ionizing radiations, a study of post in conventional and interventional radiology, study of post in interventional cardiology, the roles and the missions of the P.C.R. (person competent in radiation protection) in a subcontractor company in I.N.B. (base nuclear installation), the application of the zoning order for the activities of industrial radiography, the evolution of the statutory measures in protection of the workers against the dangers of ionizing radiations, all which concerns the P.C.R. (training, missions, certification, educational role), the controls of radioprotection, the external controls of radioprotection, the surveillance of working zones, surveillance of effluents,management of the radioactive waste and effluents, classification of the personnel and the surveillance of the exposure, dosimetry by radio photo luminescence, the systeme S.I.S.E.R.I.. (N.C.)

  11. The solar ultraviolet B radiation protection provided by shading devices with regard to its diffuse component.

    Science.gov (United States)

    Kudish, Avraham I; Harari, Marco; Evseev, Efim G

    2011-10-01

    The composition of the incident solar global ultraviolet B (UVB) radiation with regard to its beam and diffuse radiation fractions is highly relevant with regard to outdoor sun protection. This is especially true with respect to sun protection during leisure-time outdoor sun exposure at the shore and pools, where people tend to escape the sun under shade trees or different types of shading devices, e.g., umbrellas, overhangs, etc., believing they offer protection from the erythemal solar radiation. The degree of sun protection offered by such devices is directly related to the composition of the solar global UVB radiation, i.e., its beam and diffuse fractions. The composition of the incident solar global UVB radiation can be determined by measuring the global UVB (using Solar Light Co. Inc., Model 501A UV-Biometer) and either of its components. The beam component of the UVB radiation was determined by measuring the normal incidence beam radiation using a prototype, tracking instrument consisting of a Solar Light Co. Inc. Model 501A UV-Biometer mounted on an Eppley Solar Tracker Model St-1. The horizontal beam component of the global UVB radiation was calculated from the measured normal incidence using a simple geometric correlation and the diffuse component is determined as the difference between global and horizontal beam radiations. Horizontal and vertical surfaces positioned under a horizontal overhang/sunshade or an umbrella are not fully protected from exposure to solar global UVB radiation. They can receive a significant fraction of the UVB radiation, depending on their location beneath the shading device, the umbrella radius and the albedo (reflectance) of the surrounding ground surface in the case of a vertical surface. Shading devices such as an umbrella or horizontal overhang/shade provide relief from the solar global radiation and do block the solar global UVB radiation to some extent; nevertheless, a significant fraction of the solar global UVB

  12. Reliability of Sleep Measures from Four Personal Health Monitoring Devices Compared to Research-Based Actigraphy and Polysomnography

    Directory of Open Access Journals (Sweden)

    Janna Mantua

    2016-05-01

    Full Text Available Polysomnography (PSG is the “gold standard” for monitoring sleep. Alternatives to PSG are of interest for clinical, research, and personal use. Wrist-worn actigraph devices have been utilized in research settings for measures of sleep for over two decades. Whether sleep measures from commercially available devices are similarly valid is unknown. We sought to determine the validity of five wearable devices: Basis Health Tracker, Misfit Shine, Fitbit Flex, Withings Pulse O2, and a research-based actigraph, Actiwatch Spectrum. We used Wilcoxon Signed Rank tests to assess differences between devices relative to PSG and correlational analysis to assess the strength of the relationship. Data loss was greatest for Fitbit and Misfit. For all devices, we found no difference and strong correlation of total sleep time with PSG. Sleep efficiency differed from PSG for Withings, Misfit, Fitbit, and Basis, while Actiwatch mean values did not differ from that of PSG. Only mean values of sleep efficiency (time asleep/time in bed from Actiwatch correlated with PSG, yet this correlation was weak. Light sleep time differed from PSG (nREM1 + nREM2 for all devices. Measures of Deep sleep time did not differ from PSG (SWS + REM for Basis. These results reveal the current strengths and limitations in sleep estimates produced by personal health monitoring devices and point to a need for future development.

  13. The protection of personal and medical data - a call for confidentiality

    African Journals Online (AJOL)

    international and local statutory instruments that protect such personal ... management of a patient, for example between the treating physician and the ... The electronic data dilemma ... a network security specialist at AT+T Bell Laboratories in the. USA. ... profession or outside of my profession or in daily commerce with men ...

  14. Balancing speech intelligibility versus sound exposure in selection of personal hearing protection equipment for Chinook aircrews

    NARCIS (Netherlands)

    Wijngaarden, S.J. van; Rots, G.

    2001-01-01

    Background: Aircrews are often exposed to high ambient sound levels, especially in military aviation. Since long-term exposure to such noise may cause hearing damage, selection of adequate hearing protective devices is crucial. Such devices also affect speech intelligibility. When speech

  15. Nuclear Reactor RA Safety Report, Vol. 9, Radiation protection

    International Nuclear Information System (INIS)

    1986-11-01

    Instrumentation for Radiation protection existing at the RA reactor is dating mostly from the period 1957-1959 when the reactor has been built. With some minor exception it was produced in USSR. Radiation protection system was constructed based on specific design project, somewhat modified original USSR project which has been indispensable because of some modification of the building design. During the past 27 years no renewal of the instrumentation was done, only maintenance was performed. Instrumentation consists of old electronic devices which caused difficulties and even prevented regular maintenance because of lack of spare parts. Instrumentation for radiation protection at the RA reactor is classified as follows: centralized dosimetry system; stationary dosimetry instrumentation, movable and personal dosimetry systems. Apart from the scheme of dosimetry instrumentation this volume includes description of radiation protection procedures; protection devices; radiation doses and dose limit data; program for environmental radioactivity control; medical control procedures [sr

  16. Personal digital assistant-based, internet-enabled remote communication system for a wearable pneumatic biventricular assist device.

    Science.gov (United States)

    Nam, Kyoung Won; Lee, Jung Joo; Hwang, Chang Mo; Choi, Seong Wook; Son, Ho Sung; Sun, Kyung

    2007-11-01

    Currently, personal mobile communication devices have become quite common, and the applications of such devices have expanded quickly. Remote communication systems might be employed for the telemonitoring of patients or the operating status of their medical devices. In this article, we describe the development of a mobile-based artificial heart telemanagement system for use in a wearable extracorporeal pneumatic biventricular assist device, which is capable of telemonitoring and telecontrolling the operating status of the ventricular assist device from any site. The system developed herein utilized small mobile phones for the client device and adopted a standard transmission control protocol/Internet protocol communication protocol for the purposes of telecommunication. The results of in vitro and animal experiments showed that the telemanagement system developed herein operated in accordance with the desired parameters.

  17. Personal Data Protection in New Zealand: Lessons for South Africa?

    Directory of Open Access Journals (Sweden)

    A Roos

    2008-12-01

    Full Text Available In 1995 the European Union adopted a Directive on data protection. Article 25 of this Directive compels all EU member countries to adopt data protection legislation and to prevent the transfer of personal data to non-EU member countries ('third countries' that do not provide an adequate level of data protection. Article 25 results in the Directive having extra-territorial effect and exerting an influence in countries outside the EU. Like South Africa, New Zealand is a 'third' country in terms of the EU Directive on data protection. New Zealand recognised the need for data protection and adopted a data protection Act over 15 years ago. The focus of this article is on the data protection provisions in New Zealand law with a view to establishing whether South Africa can learn any lessons from them. In general, it can be said that although New Zealand law does not expressly recognise a right to privacy, it has a data protection regime that functions well and that goes a long way to providing adequate data protection as required by the EU Directive on data protection. Nevertheless, the EU has not made a finding to that effect as yet. The New Zealand data protection act requires a couple of amendments before New Zealand might be adjudged ‘adequate’. South Africa’s protection of the right to privacy and identity is better developed and more extensive than that of New Zealand. Privacy is recognised and protected in the law of delict and by the South African Constitution. Despite South Africa’s apparently high regard for the individual’s right to privacy and identity and our well-developed common and constitutional law of privacy, South Africa does not meet the adequacy requirement of the EU Directive, because we do not have a data protection Act. This means that South African participants in the information technology arena are at a constant disadvantage. It is argued that South Africa should follow New Zealand’s example and adopt a data

  18. Nonconformance in electromechanical output relays of microprocessor-based protection devices under actual operating conditions

    OpenAIRE

    Gurevich, Vladimir

    2006-01-01

    Microprocessor-based protection relays are gradually driving out traditional electromechanical and even electronic protection devices from virtually all fields of power and electrical engineering. In this paper, one of many problems of microprocessor-based relays is discussed: nonconformance of miniature electromechanical output relays under actual operation conditions: switching inductive loads (with tripping CB coils or lockout relay coils) at 220 VDC, and "dry" switching of some control ci...

  19. Towards a conceptual framework for protection of personal information from the perspective of activity theory

    Directory of Open Access Journals (Sweden)

    Tiko Iyamu

    2017-11-01

    Full Text Available Background: Personal information about individuals is stored by organisations including government agencies. The information is intended to be kept confidential and strictly used for its primary and legitimate purposes. However, that has not always been the case in many South African government agencies and departments. In recent years, personal information about individuals and groups has been illegally leaked for other motives, in which some were detrimental. Even though there exists a legislation, Protection of Personal Information (POPI Act, which prohibits such malpractices, illegally leaked information has however, not stopped or reduced. In addition to the adoption of the POPI Act, a more stringent approach is therefore needed in order to improve sanity in the use and management of personal information. Otherwise, the detriment that such malpractices cause too many citizens can only be on the increase. Objectives: The objectives of this study were in twofold: (1 to examine and understand the activities that happen with personal information leaks, which includes why and how information is leaked; and (2 to develop a conceptual framework, which includes identification of the factors that influence information leaks and breaches in an environment. Method: Qualitative research methods were followed in achieving the objectives of the study. Within the qualitative methods, documents including existing literature were gathered. The activity theory was employed as lens to guide the analysis. Result: From the analysis, four critical factors were found to be of influence in information leaks and breaches in organisations. The factors include: (1 information and its value, (2 the roles of society and its compliance to information protection, (3 government and its laws relating to information protection and (4 the need for standardisation of information usage and management within a community. Based on the factors, a conceptual framework was

  20. Device for the burst protection of nuclear reactor pressure vessels

    International Nuclear Information System (INIS)

    Daublebsky, P.

    1976-01-01

    The burst protection device has a hood over top and bottom of the pressure vessel with superimposed hinged supports lying in their turn against supporting rings which are connected with each other by vertical bracing. It is proposed to place an intermediate layer between hoods and vertical bracing absorbing thermal stresses, i.e. deforming plastically with gradually increasing pressure, but behaving like a rigid body in the case of shock loads. As a material lead e.g. is proposed. (UWI) [de

  1. Awareness training and hearing protection devices: Current practices in the South African mining industry

    CSIR Research Space (South Africa)

    Edwards, A

    2012-09-01

    Full Text Available This presentation outlines the importance of awareness training of managers at all levels and miners regarding the importance of hearing protection devices and adequate knowledge, motivation and training to prevent hearing loss....

  2. Cerebral ischemic lesions detected with diffusion-weighted magnetic resonance imaging after carotid artery stenting: Comparison of several anti-embolic protection devices.

    Science.gov (United States)

    Taha, Mahmoud M; Maeda, Masayuki; Sakaida, Hiroshi; Kawaguchi, Kenji; Toma, Naoki; Yamamoto, Akitaka; Hirose, Tomofumi; Miura, Youichi; Fujimoto, Masashi; Matsushima, Satoshi; Taki, Waro

    2009-09-01

    Distal embolism is an important periprocedural technical complication with carotid angioplasty and carotid artery stenting (CAS). We evaluated the safety and efficacy of protection devices used during CAS by detecting new cerebral ischemic lesions using diffusion-weighted magnetic resonance imaging in 95 patients who underwent 98 CAS procedures: 34 using single PercuSurge GuardWire, 31 using double balloon protection, 15 using proximal flow reverse protection devices, 14 using Naviballoon, and 4 using filter anti-embolic devices. Diffusion-weighted imaging was performed preoperatively and postoperatively to evaluate the presence of any new embolic cerebral lesions. Postoperative diffusion-weighted imaging revealed 117 new ischemic lesions. Three patients had new ischemic stroke, two minor and one major, all ipsilateral to the treated carotid artery. The remaining patients had clinically silent ischemia. The incidence of new embolic lesions was lower using the proximal flow reverse protection device than with the double balloon protection (33% vs. 48.4%), but the volume of ipsilateral new ischemic lesions per patient was 136.6 mm(3) vs. 86.9 mm(3), respectively. Neuroprotection with Naviballoon yielded ipsilateral lesions of large volume (86.6 mm(3)) and higher number (5.7 lesions per patient) than using the filter anti-embolic device (34.8 mm(3) and 1 lesion per patient). New cerebral ischemic lesions after neuroprotected CAS are usually silent. The lower incidence of distal ischemia using proximal flow reverse and double balloon protection devices is limited by the larger volume and higher number of ischemic lesions.

  3. Cerebral ischemic lesions detected with diffusion-weighted magnetic resonance imaging after carotid artery stenting. Comparison of several anti-embolic protection devices

    International Nuclear Information System (INIS)

    Taha, M.M.; Maeda, Masayuki; Sakaida, Hiroshi

    2009-01-01

    Distal embolism is an important periprocedural technical complication with carotid angioplasty and carotid artery stenting (CAS). We evaluated the safety and efficacy of protection devices used during CAS by detecting new cerebral ischemic lesions using diffusion-weighted magnetic resonance imaging in 95 patients who underwent 98 CAS procedures: 34 using single PercuSurge GuardWire, 31 using double balloon protection, 15 using proximal flow reverse protection devices, 14 using Naviballoon, and 4 using filter anti-embolic devices. Diffusion-weighted imaging was performed preoperatively and postoperatively to evaluate the presence of any new embolic cerebral lesions. Postoperative diffusion-weighted imaging revealed 117 new ischemic lesions. Three patients had new ischemic stroke, two minor and one major, all ipsilateral to the treated carotid artery. The remaining patients had clinically silent ischemia. The incidence of new embolic lesions was lower using the proximal flow reverse protection device than with the double balloon protection (33% vs. 48.4%), but the volume of ipsilateral new ischemic lesions per patient was 136.6 mm 3 vs. 86.9 mm 3 , respectively. Neuroprotection with Naviballoon yielded ipsilateral lesions of large volume (86.6 mm 3 ) and higher number (5.7 lesions per patient) than using the filter anti-embolic device (34.8 mm 3 and 1 lesion per patient). New cerebral ischemic lesions after neuroprotected CAS are usually silent. The lower incidence of distal ischemia using proximal flow reverse and double balloon protection devices is limited by the larger volume and higher number of ischemic lesions. (author)

  4. An E-government Interoperability Platform Supporting Personal Data Protection Regulations

    Directory of Open Access Journals (Sweden)

    Laura González

    2016-08-01

    Full Text Available Public agencies are increasingly required to collaborate with each other in order to provide high-quality e-government services. This collaboration is usually based on the service-oriented approach and supported by interoperability platforms. Such platforms are specialized middleware-based infrastructures enabling the provision, discovery and invocation of interoperable software services. In turn, given that personal data handled by governments are often very sensitive, most governments have developed some sort of legislation focusing on data protection. This paper proposes solutions for monitoring and enforcing data protection laws within an E-government Interoperability Platform. In particular, the proposal addresses requirements posed by the Uruguayan Data Protection Law and the Uruguayan E-government Platform, although it can also be applied in similar scenarios. The solutions are based on well-known integration mechanisms (e.g. Enterprise Service Bus as well as recognized security standards (e.g. eXtensible Access Control Markup Language and were completely prototyped leveraging the SwitchYard ESB product.

  5. Optical-electronic device based on diffraction optical element for control of special protective tags executed from luminophor

    Science.gov (United States)

    Polyakov, M.; Odinokov, S.

    2017-05-01

    The report focuses on special printing industry, which is called secure printing, which uses printing techniques to prevent forgery or falsification of security documents. The report considered the possibility of establishing a spectral device for determining the authenticity of certain documents that are protected by machine-readable luminophor labels. The device works in two spectral ranges - visible and near infrared that allows to register Stokes and anti-Stokes spectral components of protective tags. The proposed device allows verification of the authenticity of security documents based on multiple criteria in different spectral ranges. It may be used at enterprises related to the production of security printing products, expert units of law enforcement bodies at check of authenticity of banknotes and other structures.

  6. First steps in designing an all-in-one ICT-based device for persons with cognitive impairment: evaluation of the first mock-up.

    Science.gov (United States)

    Boman, Inga-Lill; Persson, Ann-Christine; Bartfai, Aniko

    2016-03-07

    This project Smart Assisted Living involving Informal careGivers++ (SALIG) intends to develop an ICT-based device for persons with cognitive impairment combined with remote support possibilities for significant others and formal caregivers. This paper presents the identification of the target groups' needs and requirements of such device and the evaluation of the first mock-up, demonstrated in a tablet. The inclusive design method that includes end-users in the design process was chosen. First, a scoping review was conducted in order to examine the target group's need of an ICT-based device, and to gather recommendations regarding its design and functionalities. In order to capture the users' requirements of the design and functionalities of the device three targeted focus groups were conducted. Based on the findings from the publications and the focus groups a user requirement specification was developed. After that a design concept and a first mock-up was developed in an iterative process. The mock-up was evaluated through interviews with persons with cognitive impairment, health care professionals and significant others. Data were analysed using content analysis. Several useful recommendations of the design and functionalities of the SALIG device for persons with cognitive impairment were identified. The main benefit of the mock-up was that it was a single device with a set of functionalities installed on a tablet and designed for persons with cognitive impairment. An additional benefit was that it could be used remotely by significant others and formal caregivers. The SALIG device has the potentials to facilitate everyday life for persons with cognitive impairment, their significant others and the work situation for formal caregivers. The results may provide guidance in the development of different types of technologies for the target population and for people with diverse disabilities. Further work will focus on developing a prototype to be empirically tested

  7. 77 FR 43008 - Unlicensed Personal Communications Service Devices in the 1920-1930 MHz Band

    Science.gov (United States)

    2012-07-23

    ... rules require use of a ``spectrum etiquette'' that specifies a process for monitoring the time and... ``listen-before-transmit'' protocol). To protect UPCS devices already using particular time and spectrum... introduce innovative products and services using Internet protocol connectivity to combine access to...

  8. Competent person for radiation protection. Practical radiation protection for base nuclear installations and installations classified for the environment protection

    International Nuclear Information System (INIS)

    Pin, A.; Perez, S.; Videcoq, J.; Ammerich, M.

    2008-01-01

    This book corresponds to the practical module devoted to the base nuclear installations and to the installations classified for the environment protection, that is to say the permanent nuclear installations susceptible to present risks for the public, environment or workers. Complied with the legislation that stipulates this module must allow to apply the acquired theoretical training to practical situations of work, it includes seven chapters as follow: generalities on access conditions in regulated areas of nuclear installation,s or installations classified for environment protection and clothing against contamination; use of control devices and management of damaged situations; methodology of working place studies, completed by the application to a real case of a study on an intervention on a containment wall; a part entitled 'take stock of the situation' ends every chapter and proposes to the reader to check its understanding and acquisition of treated knowledge. (N.C.)

  9. Towards an Active Hearing Protection Device for Musicians =

    Science.gov (United States)

    Bernier, Antoine

    Professional musicians are oftentimes exposed to high levels of sound. Prolonged or severe exposure to high sound levels could lead to permanent hearing loss and compromise their career. The logical solution would be to wear hearing protection devices (HPDs) when appropriate. However, perceptual discomfort associated with wearing HPD can discourage their use by musicians. The perceptual discomfort is caused by two detrimental effects: the occlusion effect and the isolation effect. The occlusion effect is often reported as an augmented, unnatural and annoying perception of one's own voice or instrument mechanically coupled to the head when wearing HPDs. The isolation effect is the unnatural sensation of being isolated from a given sound environment and can be caused by wearing HPDs that do not compensate for psychoacoustical factors and therefore alter the wearer's auditory perception. Both effects are highly unfavorable to the musicians' auditory perception and compromise their capacity to perform to the best of their abilities for their audience. They are among the reasons most often reported by musicians to decide not to wear HPDs. This master's project presents the concept and first prototype of an active HPD for musicians that aims at solving the detrimental effects while protecting the musician's hearing. A solution for the occlusion effect is presented in the form of an earplug complemented with in-ear active noise control. Practical design issues and required trade-off are analyzed through a literature review and the implementation and characterization of an active occlusion effect reduction system, allowing reduction of the occlusion effect between 8.5 and 12 dB at 250 Hz. A solution for the isolation effect is presented in the form of an earplug complemented with digital signal processing capabilities. Factors that may cause the isolation effect are identified through a literature review and corresponding algorithms that aim at re-establishing the

  10. The availability of appropriately fitting personal protective aprons and jackets for angiographic and interventional radiology personnel

    International Nuclear Information System (INIS)

    Cremen, S.A.; McNulty, J.P.

    2014-01-01

    Purpose: This study explored the availability of personal protective equipment, lead or lead-free aprons or jackets, in angiographic and interventional radiology suites in the Republic of Ireland with a focus on the sizes available, appropriateness of fit and purchasing practices. Methods: All centres providing an angiographic or interventional radiology service in the Republic of Ireland were invited to participate with data being collected by means of a postal questionnaire exploring the above issues. Results: The mean number of aprons or jackets available across the centres who responded to the survey was 18.4 with the majority of these, 72%, being medium or large in size. Clinical specialists in three centres identified that there were insufficient aprons or jackets sized extra small or extra large within their departments and only one centre had a purchasing policy in place where individual staff were assigned a personal apron or jacket. Conclusion: Ill-fitting aprons or jackets will reduce the shielding provided to certain body regions by personal protective equipment. The use of over-sized aprons or jackets by staff is of particular concern based on the potential for inadvertent exposure to tissues where cancers may potentially be induced due to poor armhole fit. It is important to carefully consider purchasing practices and range of personal protective equipment sizes available in order to ensure that all staff receive the greatest possible protection from occupational radiation exposure

  11. Do privacy and data protection rules apply to legal persons and should they? A proposal for a two-tiered system

    NARCIS (Netherlands)

    van der Sloot, B.

    2015-01-01

    Privacy and data protection rules are usually said to protect the individual against intrusive governments and nosy companies. These rights guarantee the individual's freedom, personal autonomy and human dignity, among others. More and more, however, legal persons are also allowed to invoke the

  12. Using scoring methods to assess the performance of CBRN personal protective systems in different scenarios.

    NARCIS (Netherlands)

    Houwelingen, T.; Kistemaker, L.A.; Kant, S. de; Hartog, E.A. den

    2010-01-01

    The past decades show an increasing variety in the design and application of personal protective equipment, PPE. Even within the PPE aimed at CBRN protection the future user can choose from a bewildering amount of producers and models. To make his predicament even worse he also has to deal with a

  13. Reactor protecting device

    International Nuclear Information System (INIS)

    Ono, Hiroshi; Kasuga, Hajime; Kasuga, Hiroshi.

    1984-01-01

    Purpose: To reduce the recycling flowrate thereby decrease the neutron flux level before the reactor shutdown upon generation of abnormality such as increase in the neutron flux, by setting the safety level lower than the value for generating the reaction scram signal. Constitution: A netron flux safety level setter and an instruction signal generator are disposed between a neutron flux detector and a recycling flowrate control device. A neutron flux safety level lower than the level for generating a reactor scram signal and higher that the level for the ordinary operation is set and, if the detection level for the neutron flux in the reactor core arrives at the safety level, a neutron flux decreasing instruction signal is outputted from the instruction signal generator to the recycling flowrate control device to thereby decrease the recycling flowrate and decrease the neutron flux without reaching the reactor shutdown, whereby the thermal safety of the fuel rod can be maintained and the reactor operation performance can be improved. (Moriyama, K.)

  14. The development of a ballistic method for simulating fragments from buried explosive devices

    NARCIS (Netherlands)

    Jagt-Deutekom, M.J. van der

    2016-01-01

    No standard scientific methodology currently exists to assess the performance of personal protection equipment (PPE) against secondary debris, such as soil, grit and stones, ejected when a buried improvised explosive device (IED) detonates. Different test methods are used for this evaluation. The

  15. Anti-Spam Legislation in Consideration of Personal Data Protection and Other Legal Instruments

    Czech Academy of Sciences Publication Activity Database

    Matejka, Ján

    2016-01-01

    Roč. 6, č. 2 (2016), s. 90-114 ISSN 1805-8396 R&D Projects: GA ČR(CZ) GA16-26910S Institutional support: RVO:68378122 Keywords : spam * personal data protection * e- marketing Subject RIV: AG - Legal Sciences

  16. Who is protecting us against the radiation protectors?

    International Nuclear Information System (INIS)

    Lorenz, Bernd

    2018-01-01

    The ICRU proposal of new radiation dose units is discusses with respect to the consequences for radiation protection in practice. For the range of 70 keV to 10 MeV gamma radiation practically no differences are obvious. The disadvantages include an increase of administrative procedures, retrofitting of measuring devices including personal dosimeters and software.

  17. When does risk perception predict protection motivation for health threats? A person-by-situation analysis

    Science.gov (United States)

    Klein, William M. P.; Avishai, Aya; Jones, Katelyn; Villegas, Megan; Sheeran, Paschal

    2018-01-01

    Although risk perception is a key concept in many health behavior theories, little research has explicitly tested when risk perception predicts motivation to take protective action against a health threat (protection motivation). The present study tackled this question by (a) adopting a multidimensional model of risk perception that comprises deliberative, affective, and experiential components (the TRIRISK model), and (b) taking a person-by-situation approach. We leveraged a highly intensive within-subjects paradigm to test features of the health threat (i.e., perceived severity) and individual differences (e.g., emotion reappraisal) as moderators of the relationship between the three types of risk perception and protection motivation in a within-subjects design. Multi-level modeling of 2968 observations (32 health threats across 94 participants) showed interactions among the TRIRISK components and moderation both by person-level and situational factors. For instance, affective risk perception better predicted protection motivation when deliberative risk perception was high, when the threat was less severe, and among participants who engage less in emotional reappraisal. These findings support the TRIRISK model and offer new insights into when risk perceptions predict protection motivation. PMID:29494705

  18. When does risk perception predict protection motivation for health threats? A person-by-situation analysis.

    Science.gov (United States)

    Ferrer, Rebecca A; Klein, William M P; Avishai, Aya; Jones, Katelyn; Villegas, Megan; Sheeran, Paschal

    2018-01-01

    Although risk perception is a key concept in many health behavior theories, little research has explicitly tested when risk perception predicts motivation to take protective action against a health threat (protection motivation). The present study tackled this question by (a) adopting a multidimensional model of risk perception that comprises deliberative, affective, and experiential components (the TRIRISK model), and (b) taking a person-by-situation approach. We leveraged a highly intensive within-subjects paradigm to test features of the health threat (i.e., perceived severity) and individual differences (e.g., emotion reappraisal) as moderators of the relationship between the three types of risk perception and protection motivation in a within-subjects design. Multi-level modeling of 2968 observations (32 health threats across 94 participants) showed interactions among the TRIRISK components and moderation both by person-level and situational factors. For instance, affective risk perception better predicted protection motivation when deliberative risk perception was high, when the threat was less severe, and among participants who engage less in emotional reappraisal. These findings support the TRIRISK model and offer new insights into when risk perceptions predict protection motivation.

  19. Tuberculosis Infection Control in Health-Care Facilities: Environmental Control and Personal Protection.

    Science.gov (United States)

    Lee, Ji Yeon

    2016-10-01

    Transmission of tuberculosis (TB) is a recognized risk to patients and healthcare workers in healthcare settings. The literature review suggests that implementation of combination control measures reduces the risk of TB transmission. Guidelines suggest a three-level hierarchy of controls including administrative, environmental, and respiratory protection. Among environmental controls, installation of ventilation systems is a priority because ventilation reduces the number of infectious particles in the air. Natural ventilation is cost-effective but depends on climatic conditions. Supplemented intervention such as air-cleaning methods including high efficiency particulate air filtration and ultraviolet germicidal irradiation should be considered in areas where adequate ventilation is difficult to achieve. Personal protective equipment including particulate respirators provides additional benefit when administrative and environmental controls cannot assure protection.

  20. Effects of Active and Passive Hearing Protection Devices on Sound Source Localization, Speech Recognition, and Tone Detection.

    Directory of Open Access Journals (Sweden)

    Andrew D Brown

    Full Text Available Hearing protection devices (HPDs such as earplugs offer to mitigate noise exposure and reduce the incidence of hearing loss among persons frequently exposed to intense sound. However, distortions of spatial acoustic information and reduced audibility of low-intensity sounds caused by many existing HPDs can make their use untenable in high-risk (e.g., military or law enforcement environments where auditory situational awareness is imperative. Here we assessed (1 sound source localization accuracy using a head-turning paradigm, (2 speech-in-noise recognition using a modified version of the QuickSIN test, and (3 tone detection thresholds using a two-alternative forced-choice task. Subjects were 10 young normal-hearing males. Four different HPDs were tested (two active, two passive, including two new and previously untested devices. Relative to unoccluded (control performance, all tested HPDs significantly degraded performance across tasks, although one active HPD slightly improved high-frequency tone detection thresholds and did not degrade speech recognition. Behavioral data were examined with respect to head-related transfer functions measured using a binaural manikin with and without tested HPDs in place. Data reinforce previous reports that HPDs significantly compromise a variety of auditory perceptual facilities, particularly sound localization due to distortions of high-frequency spectral cues that are important for the avoidance of front-back confusions.

  1. Training first responders on Radiological Dispersal Devices (RDDs) and Improvised Nuclear Devices (INDs) events

    International Nuclear Information System (INIS)

    Groves, Ken L.

    2008-01-01

    Full text: This paper will present an overview of the current training the author is presenting to First Responders (fire-fighters, emergency medical technicians, law enforcement and others) who may encounter either a Radiological Dispersal Device (RDD or Dirty Bomb) or an Improvised Nuclear Device (IND) as a part of their Emergency Response activities. The emphasis of the training is putting the radiological/nuclear material in perspective as compared with other Weapons of Mass Destruction (WMD) materials such as chemical and/or biological weapon agents. A goal of the training is to help this First Responder Community understand that under almost all conditions, they can perform their primary mission of 'putting out fires', rescuing and treating injured persons, and chasing 'bad guys' even in the presence of relatively large amount of radiological/nuclear contamination. The rare cases of high activity unshielded sources will be reviewed and explained. Current International guidance on dose 'limits' will be discussed. A discussion of the use of Time, Distance and Shielding as well as appropriate Personal Protective Clothing and how it will provide the needed protection while immediate actions take place early in an RDD/IND event, will take place. The use of appropriate radiation detection instrumentation, documented Standard Operating Procedures along with realistic training, drills and exercises are the key to a successful response to an RDD/IND event for this community of critical emergency responders. (author)

  2. La tutela constitucional de las personas con discapacidad // The constitutional protection of persons with disabilities

    Directory of Open Access Journals (Sweden)

    Héctor Álvarez García

    2017-12-01

    The work begins with an historical journey through the different models implemented by public authorities to address the phenomenon of disability. This journey culminates with the mixed paradigm —medical and social— embodied in the Spanish Constitution of 1978. The article interprets the «social protections norms» of the Constitution, in the light of the International Convention on the Rights of Persons with Disabilities and the doctrine of the Constitutional Court, in order to determine the content and scope of constitutional protection of the capacity to act of persons with disabilities. This is essential to ensure the free development of the personality of this large group of citizens, whose lives have traditionally been governed by the will of others, if not been directly deprived of their liberty through their institutionalization.

  3. Adapting cognitive radio technology for low-power wireless personal area network devices

    DEFF Research Database (Denmark)

    Toftegaard, Thomas Skjødeberg; Rohde, John

    2011-01-01

    The application of wireless personal area network (WPAN) and simple point-to-point wireless communication devices has increased drastically both in private household and in our workspaces in general over the last decade. Combined with the fact that the total number of wireless devices...... and associated standards present in the wireless environment is experiencing an extreme growth, the frequency spectrum scarcity is exposed as a severe challenge. Setting up efficient and reliable wireless WPAN links can be challenging even today. This is especially true because of the intensive use...... discusses the challenges associated with the implementation of highly reliable low-power WPAN networks for the future and the adaption of Cognitive Radio technology as a potential solution. A brief status on the maturity of CR technology will be presented as an integral part of this discussion....

  4. Personal Hearing Protection including Active Noise Reduction (Les dispositifs de protection de l'ouie, y compris l'attenuation du bruit actif) (CD-ROM)

    National Research Council Canada - National Science Library

    Steeneken, H. J; Dancer, A; McKinley, R; Buck, K; James, S

    2005-01-01

    .... SYSTEMS DETAIL NOTE: Adobe Acrobat Reader is included on disc. ABSTRACT: Personal hearing protection and speech communication facilities are essential for optimal performance in military operations...

  5. High-frequency profile in adolescents and its relationship with the use of personal stereo devices.

    Science.gov (United States)

    Silvestre, Renata Almeida Araújo; Ribas, Ângela; Hammerschmidt, Rogério; de Lacerda, Adriana Bender Moreira

    2016-01-01

    To analyze and correlate the audiometric findings of high frequencies (9-16 kHz) in adolescents with their hearing habits and attitudes, in order to prevent noise-induced hearing loss. This was a descriptive cross-sectional study, which included 125 adolescents in a sample of normal-hearing students, at a state school. The subjects performed high-frequency audiometry testing and answered a self-administered questionnaire addressing information on sound habits concerning the use of personal stereo devices. The sample was divided according to the exposure characteristics (time, duration, intensity, etc.) and the results were compared with the observed thresholds, through the difference in proportions test, chi-squared, Student's t-test, and ANOVA, all at a significance level of 0.05. Average high-frequency thresholds were registered below 15 dB HL and no significant correlation was found between high frequency audiometric findings and the degree of exposure. The prevalence of harmful sound habits due to the use of personal stereo devices is high in the adolescent population, but there was no correlation between exposure to high sound pressure levels through personal stereos and the high-frequency thresholds in this population. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  6. Personal Protective Equipment in the humanitarian governance of Ebola: between individual patient care and global biosecurity

    NARCIS (Netherlands)

    Pallister-Wilkins, P.

    2016-01-01

    This article focuses on the use of Personal Protective Equipment in humanitarianism. It takes the recent Ebola outbreak as a case through which to explore the role of objects in saving individual lives and protecting populations. The argument underlines the importance of PPE in mediating between

  7. ConstitutionalJustice: Cases of Protection of Freedom and Personal Security in Colombia

    Directory of Open Access Journals (Sweden)

    Viridiana Molinares Hassan

    2014-07-01

    Full Text Available In this paper we present the results of an investigation about judicial protection of freedom and personal security granted by the Constitutional Court (cc of Colombia, with a comparative analysis between the period 1992-2001, to which governments have appointed period of postconstitucionales, which coincides with the issuance of the 1991 Constitution, and the creation of constitutional jurisdiction, and the period 2002-2010, during which it ran the Democratic Security Policy (dsp as a government policy proposal by former president Álvaro Uribe, whose aim was to achieve peace through the declaration of war to the guerrilla group Revolutionary Armed Forces of Colombia (farc. Our interest is to show that the protection of freedom and personal security as the basis of the Constitutional (ec finds in the cc his greatest guarantor, even against closing courts in other jurisdictions that are still rooted in the failed legal positivist paradigm, ignoring the postulates of neoconstitutionalism dc sufficiently developed from a process of creative interpretation and decision-making. This coupled with the importance for the branches of power and knowledge associated scope of freedom and personal security developed by the cc in the difficult context of irregular warfare that exists in Colombia, yet it is, for universal constitutionalism, an example of the development of legal guarantor in the context of current constitutionalism.

  8. Third-year medical students' knowledge of privacy and security issues concerning mobile devices.

    Science.gov (United States)

    Whipple, Elizabeth C; Allgood, Kacy L; Larue, Elizabeth M

    2012-01-01

    The use of mobile devices are ubiquitous in medical-care professional settings, but information on privacy and security concerns of mobile devices for medical students is scarce. To gain baseline information about third-year medical students' mobile device use and knowledge of privacy and security issues concerning mobile devices. We surveyed 67 third-year medical students at a Midwestern university on their use of mobile devices and knowledge of how to protect information available through mobile devices. Students were also presented with clinical scenarios to rate their level of concern in regards to privacy and security of information. The most used features of mobile devices were: voice-to-voice (100%), text messaging (SMS) (94%), Internet (76.9%), and email (69.3%). For locking of one's personal mobile phone, 54.1% never physically lock their phone, and 58% never electronically lock their personal PDA. Scenarios considering definitely privacy concerns include emailing patient information intact (66.7%), and posting de-identified information on YouTube (45.2%) or Facebook (42.2%). As the ease of sharing data increases with the use of mobile devices, students need more education and training on possible privacy and security risks posed with mobile devices.

  9. Web software for the control and management of radiation protection devices in the Cadarache site

    International Nuclear Information System (INIS)

    Beltritti, F.

    2010-01-01

    This series of slides presents how to use a new software dedicated to the management of the periodical controls that have to be performed on the equipment involved in radiation protection. This software is ready to be dispatched on the CEA site of Cadarache. This software gives information on: the device to be controlled, the controls that have to be performed, the procedures to follow to make the test, the equipment necessary for the test particularly the need for radioactive sources, the maintenance of the device, the previous measurements and in the end the device's conformity. An evaluation of the conformity of all the devices present in a building or an area or of a particular type can be easily obtained. (A.C.)

  10. DEVELOPMENT OF PERSONAL PROTECTIVE EQUIPMENT FOR DECONTAMINATION AND DECOMMISSIONING

    International Nuclear Information System (INIS)

    Ebadian, M.A.

    1999-01-01

    The purpose of this one-year investigation is to perform a technology integration/search, thereby ensuring that the safest and most cost-effective options are developed and subsequently used during the deactivation and decommissioning (D and D) of U.S. Department of Energy Environmental Management (DOE-EM) sites. Issues of worker health and safety are the main concern, followed by cost. Two lines of action were explored: innovative Personal Cooling Systems (PCS) and Personal Monitoring Equipment (PME). PME refers to sensors affixed to the worker that warn of an approaching heat stress condition, thereby preventing it. Three types of cooling systems were investigated: Pre-Chilled or Forced-Air System (PCFA), Umbilical Fluid-Chilled System (UFCS), and Passive Vest System (PVS). Of these, the UFCS leads the way. The PVS or Gel pack vest lagged due to a limited cooling duration. And the PCFA or chilled liquid air supply was cumbersome and required an expensive and complex recharge system. The UFCS in the form of the Personal Ice Cooling System (PICS) performed exceptionally. The technology uses a chilled liquid circulating undergarment and a Personal Protective Equipment (PPE) external pump and ice reservoir. The system is moderately expensive, but the recharge is low-tech and inexpensive enough to offset the cost. There are commercially available PME that can be augmented to meet the DOE's heat stress alleviation need. The technology is costly, in excess of $4,000 per unit. Workers easily ignore the alarm. The benefit to health and safety is indirect so can be overlooked. A PCS is a more justifiable expenditure

  11. Decree of the 29. december 2003 relative to the education modes of the competent person in radiation protection and the trainer certification

    International Nuclear Information System (INIS)

    2004-01-01

    This decree details the content of the training of the radiation protection competent person that must allow to the applicant to execute the missions assigned by the article R.231-106 from the Labour code. The different chapters are as follow: radioactivity; radiation-matter interaction; protection principle against external exposure; protection principle against contamination; radiation detection; biological radiation effects; exposure sources for man; regulation; the work of the competent person in radiation protection; optimization in radiation protection. (N.C.)

  12. Aging assessment of surge protective devices in nuclear power plants

    International Nuclear Information System (INIS)

    Davis, J.F.; Subudhi, M.; Carroll, D.P.

    1996-01-01

    An assessment was performed to determine the effects of aging on the performance and availability of surge protective devices (SPDs), used in electrical power and control systems in nuclear power plants. Although SPDs have not been classified as safety-related, they are risk-important because they can minimize the initiating event frequencies associated with loss of offsite power and reactor trips. Conversely, their failure due to age might cause some of those initiating events, e.g., through short circuit failure modes, or by allowing deterioration of the safety-related component(s) they are protecting from overvoltages, perhaps preventing a reactor trip, from an open circuit failure mode. From the data evaluated during 1980--1994, it was found that failures of surge arresters and suppressers by short circuits were neither a significant risk nor safety concern, and there were no failures of surge suppressers preventing a reactor trip. Simulations, using the ElectroMagnetic Transients Program (EMTP) were performed to determine the adequacy of high voltage surge arresters

  13. New challenge for the radiation protection: devices for the radioactivity dispersion

    International Nuclear Information System (INIS)

    Mora, J. C.; Robles, B.; Cancio, C.

    2006-01-01

    In recent years the terrorist attacks produced in several countries have changed the mind of the security experts. This has also included the Radiation Protection aspects. Newly considered features have required the update of emergency response and preparedness, ad well as a greater emphasis on security. Within the Radiation Protection field has been introduced the radiological and nuclear terrorism definition. almost every organism and research centre involved in Radiation Protection is nowadays working on. The possible terrorist attack scenarios have already been defined and the use of an explosive to disperse radioactive material, known as a Radiation Dispersion Devices (RDD), has been specified as the most probable one. Studies to mitigate against the chance of attack and to mitigate the consequences of any attack with a RDD are complex, due to the innovation that introduce. This leads to a need to take some immediate preventative actions and to carry out additional R and D efforts. This document presents some considerations on the possible RDD design and behaviour in order to prevent and prepare against a possible attack. (Author) 17 refs

  14. Employers' Statutory Vicarious Liability in Terms of the Protection of Personal Information Act

    Directory of Open Access Journals (Sweden)

    Daleen Millard

    2016-07-01

    Full Text Available A person whose privacy has been infringed upon through the unlawful, culpable processing of his or her personal information can sue the infringer's employer based on vicarious liability or institute action based on the Protection of Personal Information Act 4 of 2013 (POPI. Section 99(1 of POPI provides a person (a "data subject" whose privacy has been infringed upon with the right to institute a civil action against the responsible party. POPI defines the responsible party as the person who determines the purpose of and means for the processing of the personal information of data subjects. Although POPI does not equate a responsible party to an employer, the term "responsible party" is undoubtedly a synonym for "employer" in this context. By holding an employer accountable for its employees' unlawful processing of a data subject's personal information, POPI creates a form of statutory vicarious liability. Since the defences available to an employer at common law and developed by case law differ from the statutory defences available to an employer in terms of POPI, it is necessary to compare the impact this new statute has on employers. From a risk perspective, employers must be aware of the serious implications of POPI. The question that arises is whether the Act perhaps takes matters too far. This article takes a critical look at the statutory defences available to an employer in vindication of a vicarious liability action brought by a data subject in terms of section 99(1 of POPI. It compares the defences found in section 99(2 of POPI and the common-law defences available to an employer fending off a delictual claim founded on the doctrine of vicarious liability. To support the argument that the statutory vicarious liability created by POPI is too harsh, the defences contained in section 99(2 of POPI are further analogised with those available to an employer in terms of section 60(4 of the Employment Equity Act 55 of 1998 (EEA and other

  15. Balance between Privacy Protecting and Selling User Data of Wearable Devices

    OpenAIRE

    Huang, Kuang-Chiu; Hsu, Jung-Fang

    2017-01-01

    Smart bracelets are capable of identifying individual data, which can synchronize the step count, mileage, calorie consumption, heart rate, sleeping data and even the pictures users uploaded with the APP. This feature is so convenient on one hand but makes us lose control of our privacy on the other hand. With poor privacy protection mechanism embedded in these wearable devices that hackers can easily invade and steal user data. In addition, most smart bracelet companies have not made a clear...

  16. Polycyclic aromatic hydrocarbons produced by electrocautery smoke and the use of personal protective equipment 1

    Directory of Open Access Journals (Sweden)

    Caroline Vieira Claudio

    Full Text Available ABSTRACT Objective: analyze the concentration of polycyclic aromatic hydrocarbons in electrocautery smoke in operating rooms and the use of personal protective equipment by the intraoperative team when exposed to hydrocarbons. Method: exploratory and cross-sectional field research conducted in a surgery center. Gases were collected by a vacuum suction pump from a sample of 50 abdominal surgeries in which an electrocautery was used. A form was applied to identify the use of personal protective equipment. Gases were analyzed using chromatography. Descriptive statistics and Spearman's test were used to treat data. Results: there were 17 (34% cholecystectomies with an average duration of 136 minutes, while the average time of electrocautery usage was 3.6 minutes. Airborne hydrocarbons were detected in operating rooms in 100% of the surgeries. Naphthalene was detected in 48 (96.0% surgeries and phenanthrene in 49 (98.0%. The average concentration of these compounds was 0.0061 mg/m3 and a strong correlation (0.761 was found between them. The intraoperative teams did not use respirator masks such as the N95. Conclusion: electrocautery smoke produces gases that are harmful to the health of the intraoperative team, which is a concern considering the low adherence to the use of personal protective equipment.

  17. Distal protection filter device efficacy with carotid artery stenting: comparison between a distal protection filter and a distal protection balloon.

    Science.gov (United States)

    Iko, Minoru; Tsutsumi, Masanori; Aikawa, Hiroshi; Matsumoto, Yoshihisa; Go, Yoshinori; Nii, Kouhei; Abe, Gorou; Ye, Iwae; Nomoto, Yasuyuki; Kazekawa, Kiyoshi

    2013-01-01

    This retrospective study aimed to compare the effectiveness of the embolization prevention mechanism of two types of embolic protection device (EPD)-a distal protection balloon (DPB) and a distal protection filter (DPF). Subjects were 164 patients scheduled to undergo carotid artery stenting: a DPB was used in 82 cases (DPB group) from April 2007 until June 2010, and a DPF was used in 82 cases (DPF group) from July 2010 to July 2011. Rates of positive findings on postoperative diffusion-weighted imaging (DWI) and stroke incidence were compared. Positive postoperative DWI results were found in 34 cases in the DPB group (41.4 %), but in only 22 cases in the DPF group (26.8 %), and there was only a small significant difference within the DPF group. In the DPB group, there was one case of transient ischemic attack (TIA) (1.2 %) and four cases of brain infarction (2 minor strokes, 2 major strokes; 4.9 %), compared to the DFP group with one case of TIA (1.2 %) and no cases of minor or major strokes. In this study, significantly lower rates of occurrence of DWI ischemic lesions and intraoperative embolization were associated with use of the DPF compared to the DPB.

  18. Effects of Hearing Protection Device Attenuation on Unmanned Aerial Vehicle (UAV) Audio Signatures

    Science.gov (United States)

    2016-03-01

    UAV ) Audio Signatures by Melissa Bezandry, Adrienne Raglin, and John Noble Approved for public release; distribution...Research Laboratory Effects of Hearing Protection Device Attenuation on Unmanned Aerial Vehicle ( UAV ) Audio Signatures by Melissa Bezandry...Aerial Vehicle ( UAV ) Audio Signatures 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Melissa Bezandry

  19. Safety and effectiveness of the INVATEC MO.MA proximal cerebral protection device during carotid artery stenting: results from the ARMOUR pivotal trial.

    Science.gov (United States)

    Ansel, Gary M; Hopkins, L Nelson; Jaff, Michael R; Rubino, Paolo; Bacharach, J Michael; Scheinert, Dierk; Myla, Subbarao; Das, Tony; Cremonesi, Alberto

    2010-07-01

    The multicenter ARMOUR (ProximAl PRotection with the MO.MA Device DUring CaRotid Stenting) trial evaluated the 30-day safety and effectiveness of the MO.MA Proximal Cerebral Protection Device (Invatec, Roncadelle, Italy) utilized to treat high surgical risk patients undergoing carotid artery stenting (CAS). Distal embolic protection devices (EPD) have been traditionally utilized during CAS. The MO.MA device acts as a balloon occlusion "endovascular clamping" system to achieve cerebral protection prior to crossing the carotid stenosis. This prospective registry enrolled 262 subjects, 37 roll-in and 225 pivotal subjects evaluated with intention to treat (ITT) from September 2007 to February 2009. Subjects underwent CAS using the MO.MA device. The primary endpoint, myocardial infarction, stroke, or death through 30 days (30-day major adverse cardiac and cerebrovascular events [MACCE]) was compared to a performance goal of 13% derived from trials utilizing distal EPD. For the ITT population, the mean age was 74.7 years with 66.7% of the cohort being male. Symptomatic patients comprised 15.1% and 28.9% were octogenarians. Device success was 98.2% and procedural success was 93.2%. The 30-day MACCE rate was 2.7% [95% CI (1.0-5.8%)] with a 30-day major stroke rate of 0.9%. No symptomatic patient suffered a stroke during this trial. The ARMOUR trial demonstrated that the MO.MA(R) Proximal Cerebral Protection Device is safe and effective for high surgical risk patients undergoing CAS. The absence of stroke in symptomatic patients is the lowest rate reported in any independently adjudicated prospective multicenter registry trial to date. (c) 2010 Wiley-Liss, Inc.

  20. Absorbed doses by a technician, with and without (simulating) use of protection devices, in bone scintigraphy examination

    International Nuclear Information System (INIS)

    Jesus Lopes Filho, F. de; Antonio Filho, J.; Colaco, W.; Silveira, S.V. da

    1992-01-01

    The relation between the whole-body dose and the dose localized in body pants of a technician work in nuclear medicine was investigated by dosimetric films and thermoluminescent dosemeters. The investigation was made with and without a suitable protection devices. The results were discussed by a radiological protection view. (C.G.C.)

  1. How Uninformed is the Average Data Subject? A Quest for Benchmarks in EU Personal Data Protection

    Directory of Open Access Journals (Sweden)

    Gloria González Fuster

    2014-11-01

    Full Text Available

    Information obligations have always been crucial in personal data protection law. Reinforcing these obligations is one of the priorities of the legislative package introduced in 2012 by the European Commission to redefine the personal data protection legal landscape of the European Union (EU. Those responsible for processing personal data (the data controllers must imperatively convey certain pieces of information to those whose data is processed (the data subjects, and they are expected to do so in an increasingly transparent manner. Beyond these punctual information requirements, however, data subjects appear to always be and inevitably remain in a state of relative ignorance, as in almost constant need of further guidance. Data subjects are nowadays often depicted as unknowing consumers of online services, services which surreptitiously take away from them personal data thus conceived as a valuable asset. In light of these developments, this contribution critically investigates how EU law is envisaging data subjects in terms of knowledge. The paper reviews the birth and evolution of information obligations as an element of European personal data protection law, and asks whether thinking of data subjects as consumers is consistent with the notion of average consumer functioning in EU consumer law. Finally, it argues that the time might have come to openly clarify when data subjects are unlawfully misinformed, and that, in the meantime, individuals might benefit not only from accessing more transparent information, but also from being made more aware of the limitations of the information available to them.   

  2. Fish-protection devices at unscreened water diversions can reduce entrainment: evidence from behavioural laboratory investigations

    Science.gov (United States)

    Poletto, Jamilynn B.; Cocherell, Dennis E.; Mussen, Timothy D.; Ercan, Ali; Bandeh, Hossein; Kavvas, M. Levent; Cech, Joseph J.; Fangue, Nann A.

    2015-01-01

    Diversion (i.e. extraction) of water from rivers and estuaries can potentially affect native wildlife populations if operation is not carefully managed. For example, open, unmodified water diversions can act as a source of injury or mortality to resident or migratory fishes from entrainment and impingement, and can cause habitat degradation and fragmentation. Fish-protection devices, such as exclusion screens, louvres or sensory deterrents, can physically or behaviourally deter fish from approaching or being entrained into water diversions. However, empirical assessment of their efficacy is often lacking or is investigated only for particular economically or culturally important fishes, such as salmonids. The Southern population of anadromous green sturgeon (Acipenser medirostris) is listed as threatened in California, and there is a high density of water diversions located within their native range (the Sacramento–San Joaquin watershed). Coupled with their unique physiology and behaviour compared with many other fishes native to California, the green sturgeon is susceptible to entrainment into diversions and is an ideal species with which to study the efficacy of mitigation techniques. Therefore, we investigated juvenile green sturgeon (188–202 days post-hatch) in the presence of several fish-protection devices to assess behaviour and entrainment risk. Using a large experimental flume (∼500 kl), we found that compared with an open diversion pipe (control), the addition of a trash-rack box, louvre box, or perforated cylinder on the pipe inlet all significantly reduced the proportion of fish that were entrained through the pipe (P = 0.03, P = 0.028, and P = 0.028, respectively). Likewise, these devices decreased entrainment risk during a single movement past the pipe by between 60 and 96%. These fish-protection devices should decrease the risk of fish entrainment during water-diversion activities. PMID:27293725

  3. Protective personality traits: High openness and low neuroticism linked to better memory in multiple sclerosis.

    Science.gov (United States)

    Leavitt, Victoria M; Buyukturkoglu, Korhan; Inglese, Matilde; Sumowski, James F

    2017-11-01

    Memory impairment in multiple sclerosis (MS) is common, although few risk/protective factors are known. To examine relationships of personality to memory/non-memory cognition in MS. 80 patients completed a cognitive battery and a personality scale measuring the "Big 5" traits: openness, neuroticism, agreeableness, extraversion, and conscientiousness. Memory was most related to openness, with higher openness linked to better memory and lower risk for memory impairment, controlling for age, atrophy, education, and intelligence quotient (IQ). Lower neuroticism was also related to better memory, and lower conscientiousness to memory impairment. Non-memory cognition was unrelated to personality. Personality may inform predictive models of memory impairment in MS.

  4. Conveying facial expressions to blind and visually impaired persons through a wearable vibrotactile device.

    Science.gov (United States)

    Buimer, Hendrik P; Bittner, Marian; Kostelijk, Tjerk; van der Geest, Thea M; Nemri, Abdellatif; van Wezel, Richard J A; Zhao, Yan

    2018-01-01

    In face-to-face social interactions, blind and visually impaired persons (VIPs) lack access to nonverbal cues like facial expressions, body posture, and gestures, which may lead to impaired interpersonal communication. In this study, a wearable sensory substitution device (SSD) consisting of a head mounted camera and a haptic belt was evaluated to determine whether vibrotactile cues around the waist could be used to convey facial expressions to users and whether such a device is desired by VIPs for use in daily living situations. Ten VIPs (mean age: 38.8, SD: 14.4) and 10 sighted persons (SPs) (mean age: 44.5, SD: 19.6) participated in the study, in which validated sets of pictures, silent videos, and videos with audio of facial expressions were presented to the participant. A control measurement was first performed to determine how accurately participants could identify facial expressions while relying on their functional senses. After a short training, participants were asked to determine facial expressions while wearing the emotion feedback system. VIPs using the device showed significant improvements in their ability to determine which facial expressions were shown. A significant increase in accuracy of 44.4% was found across all types of stimuli when comparing the scores of the control (mean±SEM: 35.0±2.5%) and supported (mean±SEM: 79.4±2.1%) phases. The greatest improvements achieved with the support of the SSD were found for silent stimuli (68.3% for pictures and 50.8% for silent videos). SPs also showed consistent, though not statistically significant, improvements while supported. Overall, our study shows that vibrotactile cues are well suited to convey facial expressions to VIPs in real-time. Participants became skilled with the device after a short training session. Further testing and development of the SSD is required to improve its accuracy and aesthetics for potential daily use.

  5. A simple device to protect against osteoradionecrosis induced by interstitial irradiation

    International Nuclear Information System (INIS)

    Levendag, P.C.; Visch, L.L.; Driver, N.

    1990-01-01

    The incidence of osteoradionecrosis has declined since the introduction of preventive oral hygiene programs and meticulous dental evaluations before and after irradiation. Nevertheless, radiation dose per se still remains an important factor in osteoradionecrosis. Interstitial radiation has received much attention in the past decade since the use of flexible afterloading systems. It has become common practice in large oncology centers to implant radiation carriers in bulky tumor in the oral cavity and/or oropharynx. For interstitial radiation, with or without external radiation, minimal tumor doses are often cited to be more than 70 Gy. Unfortunately, if the mandible receives more than 70 Gy, it is at risk for the development of osteoradionecrosis. Therefore a simple protective lead device has been designed for routine use in brachytherapy in oral cavity tumors to reduce the dose to the mandible. This device will diminish the potential risk of osteoradionecrosis development

  6. Identification, investigation and analysis of end-of-wind protection devices for vertical and incline shafts.

    CSIR Research Space (South Africa)

    Ottermann, RW

    2000-12-01

    Full Text Available The occurrence and cause of overwind and underwind events in underground mining were investigated in conjunction with devices, which are at present being applied to prevent and control such incidents. Proposals for in-shaft systems to protect...

  7. Operator dermal exposure and protection provided by personal protective equipment and working coveralls during mixing/loading, application and sprayer cleaning in vineyards.

    Science.gov (United States)

    Thouvenin, Isabelle; Bouneb, Françoise; Mercier, Thierry

    2017-06-01

    The efficiency of a working coverall combined with personal protective equipment to protect operators against dermal exposure to plant protection products under field conditions was studied. Operators wore a non-certified water-repellent finish polyester/cotton coverall plus a certified gown during the mixing/loading and the cleaning phases. Insecticide foliar application to a vineyard was selected as the exposure scenario. The overall dermal residue levels measured in this study were in the range of data recently collected in Europe. The water-repellent finish working coverall reduced body exposure by a factor of approximately 95%. Wearing a Category III Type 3 partial body gown during mixing/loading and cleaning of the application equipment led to a further protective effect of 98.7%. The combination of a water-repellent finish working coverall and partial body protection during specific tasks provided satisfactory levels of protection and can be considered as suitable protection for the conditions of use studied.

  8. [The real-world effectiveness of personal protective equipment and additional risks for workers' health].

    Science.gov (United States)

    Denisov, É I; Morozova, T V; Adeninskaia, E E; Kur'erov, N N

    2013-01-01

    The effectiveness of personal protective equipment (PPE) of hearing, respiratory organs and hands is considered. It is shown that real effect of PPE is twice lower than declared by supplier; this presumes some derating system. The aspects of discomfort and additional risks are analyzed. The hygienic and physiologic evaluation of PPE is required along with elaboration of an official document (OSH standard or sanitary regulation) on selection, personal fit, organization of use and individual training of workers and their motivation.

  9. Instructed officers Radiation Protection

    International Nuclear Information System (INIS)

    2007-01-01

    This law contains instructions on the prevention of radiological and contains 4 articles Article I: describe the responsibilities of the institutions that operate within the scope of radiological protection in terms of the number of radiation protection officers and personal Supervisors who available in the practices radiation field. Article II: talking about the conditions of radiation protection officers that must be available in the main officers and working field in larg institutions and thecondition of specific requirements for large enterprises of work permits in the field of radiological work that issued by the Council. Article III: the functions and duties of officers in the prevention of radiological oversee the development of radiation protection programmes in the planning stages, construction and preparing the rules of local labour and what it lead of such tasks.Article IV: radiation protection officers powers: to modify and approve the programme of prevention and radiation safety at the company, stop any unsafe steps, amend the steps of the usage, operation of materials, devices and so on

  10. Development of radiation protection and measurement technology

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Si Young; Lee, T. Y.; Kim, J. L.; Kim, B. H.; Lee, B. J.; Chung, K. K.; Lee, K. C.; Chung, R. I.; Han, Y. D.; Kim, J. S.; Lee, H. S.; Kim, C. K.; Yoon, K. S.; Jeong, D. Y.; Yoon, S. C.; Yoon, Y. C.; Lee, S. Y.; Kim, J. S.; Seo, K. W. [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); Kim, J. K.; Lee, J. K. [Hanyang Univ., Seoul (Korea, Republic of)

    1997-07-01

    Reference X-, gamma, beta and neutron radiation fields complying with the ISO and ANSI standards have been established and evaluated to provide a basic technical support in national radiation protection dosimetry program and to provide calibration measurement devices. Personal dose evaluation algorithm has been developed with these reference radiation fields, which comply well with both domestic and the new ANSI N13.11, to evaluate accurate personal dose equivalents. A personal internal dosimetry algorithm which can estimate the intakes of radionuclides from the results of in vivo bioassay and the resulting internal doses has been developed and verified its performance. It was also evaluated to be equality excellent compared with those being used in foreign countries and used to make a computer code for internal dose evaluation which can be run with PC under the Windows environment. A BOMAB phantom for precise calibration of in vivo system has been also designed, fabricated and test-evaluated. Based on the ALARA concept of the optimization principle of radiation protection, a method for estimating the cost for radiation protection has been studied and an objective monetary cost of detriment due to radiation exposure, called {alpha} value ($/man-Sv) has been derived and proposed based on the Korean socio-economic situation and human risk factors to provide basic data for the radiation protection optimization study in Korea. (author). 100 refs., 104 tabs., 69 figs.

  11. PhysioDroid: combining wearable health sensors and mobile devices for a ubiquitous, continuous, and personal monitoring.

    Science.gov (United States)

    Banos, Oresti; Villalonga, Claudia; Damas, Miguel; Gloesekoetter, Peter; Pomares, Hector; Rojas, Ignacio

    2014-01-01

    Technological advances on the development of mobile devices, medical sensors, and wireless communication systems support a new generation of unobtrusive, portable, and ubiquitous health monitoring systems for continuous patient assessment and more personalized health care. There exist a growing number of mobile apps in the health domain; however, little contribution has been specifically provided, so far, to operate this kind of apps with wearable physiological sensors. The PhysioDroid, presented in this paper, provides a personalized means to remotely monitor and evaluate users' conditions. The PhysioDroid system provides ubiquitous and continuous vital signs analysis, such as electrocardiogram, heart rate, respiration rate, skin temperature, and body motion, intended to help empower patients and improve clinical understanding. The PhysioDroid is composed of a wearable monitoring device and an Android app providing gathering, storage, and processing features for the physiological sensor data. The versatility of the developed app allows its use for both average users and specialists, and the reduced cost of the PhysioDroid puts it at the reach of most people. Two exemplary use cases for health assessment and sports training are presented to illustrate the capabilities of the PhysioDroid. Next technical steps include generalization to other mobile platforms and health monitoring devices.

  12. Implementation methodology for interoperable personal health devices with low-voltage low-power constraints.

    Science.gov (United States)

    Martinez-Espronceda, Miguel; Martinez, Ignacio; Serrano, Luis; Led, Santiago; Trigo, Jesús Daniel; Marzo, Asier; Escayola, Javier; Garcia, José

    2011-05-01

    Traditionally, e-Health solutions were located at the point of care (PoC), while the new ubiquitous user-centered paradigm draws on standard-based personal health devices (PHDs). Such devices place strict constraints on computation and battery efficiency that encouraged the International Organization for Standardization/IEEE11073 (X73) standard for medical devices to evolve from X73PoC to X73PHD. In this context, low-voltage low-power (LV-LP) technologies meet the restrictions of X73PHD-compliant devices. Since X73PHD does not approach the software architecture, the accomplishment of an efficient design falls directly on the software developer. Therefore, computational and battery performance of such LV-LP-constrained devices can even be outperformed through an efficient X73PHD implementation design. In this context, this paper proposes a new methodology to implement X73PHD into microcontroller-based platforms with LV-LP constraints. Such implementation methodology has been developed through a patterns-based approach and applied to a number of X73PHD-compliant agents (including weighing scale, blood pressure monitor, and thermometer specializations) and microprocessor architectures (8, 16, and 32 bits) as a proof of concept. As a reference, the results obtained in the weighing scale guarantee all features of X73PHD running over a microcontroller architecture based on ARM7TDMI requiring only 168 B of RAM and 2546 B of flash memory.

  13. 78 FR 12065 - National Institute for Occupational Safety and Health Personal Protective Technology for...

    Science.gov (United States)

    2013-02-21

    ... Institute for Occupational Safety and Health Personal Protective Technology for Pesticide Handlers: Stakeholder Meeting AGENCY: The National Institute for Occupational Safety and Health (NIOSH) of the Centers...: Notice of public meeting. SUMMARY: The National Institute for Occupational Safety and Health (NIOSH) of...

  14. A New PDR Navigation Device for Challenging Urban Environments

    Directory of Open Access Journals (Sweden)

    Miguel Ortiz

    2017-01-01

    Full Text Available The motivations, the design, and some applications of the new Pedestrian Dead Reckoning (PDR navigation device, ULISS (Ubiquitous Localization with Inertial Sensors and Satellites, are presented in this paper. It is an original device conceived to follow the European recommendation of privacy by design to protect location data which opens new research toward self-contained pedestrian navigation approaches. Its application is presented with an enhanced PDR algorithm to estimate pedestrian’s footpaths in an autonomous manner irrespective of the handheld device carrying mode: texting or swinging. An analysis of real-time coding issues toward a demonstrator is also conducted. Indoor experiments, conducted with 3 persons, give a 5.8% mean positioning error over the 3 km travelled distances.

  15. Development of the self-learning machine for creating models of microprocessor of single-phase earth fault protection devices in networks with isolated neutral voltage above 1000 V

    Science.gov (United States)

    Utegulov, B. B.; Utegulov, A. B.; Meiramova, S.

    2018-02-01

    The paper proposes the development of a self-learning machine for creating models of microprocessor-based single-phase ground fault protection devices in networks with an isolated neutral voltage higher than 1000 V. Development of a self-learning machine for creating models of microprocessor-based single-phase earth fault protection devices in networks with an isolated neutral voltage higher than 1000 V. allows to effectively implement mathematical models of automatic change of protection settings. Single-phase earth fault protection devices.

  16. Device for protecting the containment vessel dome of a nuclear reactor

    International Nuclear Information System (INIS)

    Allain, A.; Filloleau, E.; Mulot, P.

    1976-01-01

    A device is disclosed for protecting the dome of a nuclear reactor containment vessel against the upward displacement of the concrete shield slab of said reactor and the resultant effects of tilting of an equipment unit mounted on the shield slab at the periphery of said slab, wherein said device comprises: (1) means for separating the equipment unit into two sections consisting of an upper section and a lower section, said lower section being rigidly fixed to said shield slab and said means being actuated by the upward displacement of said slab, (2) a system for vertical rectilinear guiding of said upper section within the containment vessel, and (3) rigid mechanical components which provide a coupling between the aforesaid upper and lower sections of the equipment unit and exert on said upper section under the action of the tilting motion of said lower section a thrust which causes the upward displacement of said upper section

  17. Final report and documentation for the security enabled programmable switch for protection of distributed internetworked computers LDRD.

    Energy Technology Data Exchange (ETDEWEB)

    Van Randwyk, Jamie A.; Robertson, Perry J.; Durgin, Nancy Ann; Toole, Timothy J.; Kucera, Brent D.; Campbell, Philip LaRoche; Pierson, Lyndon George

    2010-02-01

    An increasing number of corporate security policies make it desirable to push security closer to the desktop. It is not practical or feasible to place security and monitoring software on all computing devices (e.g. printers, personal digital assistants, copy machines, legacy hardware). We have begun to prototype a hardware and software architecture that will enforce security policies by pushing security functions closer to the end user, whether in the office or home, without interfering with users' desktop environments. We are developing a specialized programmable Ethernet network switch to achieve this. Embodied in this device is the ability to detect and mitigate network attacks that would otherwise disable or compromise the end user's computing nodes. We call this device a 'Secure Programmable Switch' (SPS). The SPS is designed with the ability to be securely reprogrammed in real time to counter rapidly evolving threats such as fast moving worms, etc. This ability to remotely update the functionality of the SPS protection device is cryptographically protected from subversion. With this concept, the user cannot turn off or fail to update virus scanning and personal firewall filtering in the SPS device as he/she could if implemented on the end host. The SPS concept also provides protection to simple/dumb devices such as printers, scanners, legacy hardware, etc. This report also describes the development of a cryptographically protected processor and its internal architecture in which the SPS device is implemented. This processor executes code correctly even if an adversary holds the processor. The processor guarantees both the integrity and the confidentiality of the code: the adversary cannot determine the sequence of instructions, nor can the adversary change the instruction sequence in a goal-oriented way.

  18. Guidance on the use of protective lead aprons in medical radiology protection efficiency and correction factors for personal dosimetry

    International Nuclear Information System (INIS)

    Franken, Y.

    2002-01-01

    Workers in clinical radiology wear lead aprons when standing in the vicinity of a patient being exposed to x-rays. A lead apron protects the person's trunk against radiation scattered rom the patient. Our research is focused on two main issues: 1. How much protection does a lead apron provide, and what are the main factors that determine the protection efficiency 2. How can measured badge dose be translated into a realistic estimate of the effective dose, and how does this depend on dosemeter placement Using a model for x-ray shielding and dosimetry we calculated equivalent organ doses and personal depth dose HP(10) for various exposure conditions, x-ray energies and types of aprons that occur in clinical practice. We concluded that apron model and fit are often more important than lead thickness. In others, increasing lead thickness of a badly chosen apron will not provide better protection. For many fluoroscopy applications an apron of good model and fit need not be thicker than 0.5 mm of lead (equivalent). In case of intensive and frequent interventional work lead we advise higher lead thickness (0.35 mm), and preferably additional neck shielding for protection of the oesophagus and thyroid. A well chosen lead apron reduces effective dose by 75%up to 90%. We also concluded that the dosemeter badge should always be worn outside the apron, at mid front of collar or chest. In our view this dosemeter position enables reliable evaluation of effective dose from badge readings. As a standard practice we recommend translating measured badge dose to effective dose by dividing by a factor of five, provide that the worker wears a suitable lead apron. Finally, some research was done on the subject of the protective effect of lead aprons for the uterus, and the relation of uterus dose and badge dose. Use of a lead apron is found to reduce uterus dose by a factor of 5 to 10. Our study shows that in case of worker pregnancy, exposure of the unborn child may de adequately

  19. Promoting fluoroscopic personal radiation protection equipment: unfamiliarity, facts and fears

    International Nuclear Information System (INIS)

    Balter, Stephen

    2017-01-01

    An incomplete understanding of risk can cause inappropriate fear. Personal protective equipment (PPE) offered for the prevention of brain cancer in interventional fluoroscopists (IR-PPE). Similar items are offered for cell-phone use (RF-PPE). Publications on fluoroscopy staff brain cancer and similar papers on cell-phone induced brain cancer were reviewed. An internet safety product search was performed, which resulted in many tens of thousands of hits. Vendor claims for either ionizing radiation or radio frequency products seldom addressed the magnitude of the risk. Individuals and institutions can buy a wide variety of safety goods. Any purchase of radioprotective equipment reduces the funds available to mitigate other safety risks. The estimated cost of averting an actuarial fatal brain cancer appears to be in the order of magnitude $10 000 000-$100 000 000. Unwarranted radiation fears should not drive the radiation protection system to the point of decreasing overall safety. (authors)

  20. STRAPIR, an European initiative for optimizing radiation protection in interventional radiology

    International Nuclear Information System (INIS)

    Vano, E.; Gonzalez, L.; Loon, R. van; Padovani, R.; Maccia, C.; Eggermont, G.

    1997-01-01

    In 1995, a European initiative for optimizing radiation protection in interventional radiology was proposed by 8 research groups. The project acronym was STPAPIR (Staff Radiation Protection in Interventional Radiology). Interventional Radiology involves an important number of specialists and their risk level is not well known, since dosimetric records exhibit important discrepancies. Many professionals using these techniques are not radiologists and the basic rules of radiation protection, known by radiologists, are not always correctly and completely followed, hence the use of protection devices is not as regular as desirable. Additionally, x-ray systems not specifically designed for interventional procedures are still used in many hospitals, what entails a significant occupational risk increase to the specialists. Some relevant questions for regulatory bodies are presented, namely, reliability of the actual data banks for occupational dosimetry, use of two personal dosimeters for assessing effective dose, actions to strengthen the systematic use of personal dosimeters and protection tools, proposals for specific training in radiation protection and use of x-ray systems specifically designed for interventional procedures, publication of reports about accidents and incidents, are also discussed. (author)

  1. Radiation protection in screening children's hips

    International Nuclear Information System (INIS)

    Heribanova, A.; Skokanova, K.; Sevc, J.; Paskova, Z.; Mundilova, M.

    1987-01-01

    Repeat hygienic investigation of the conditions of radiation protection in preventive screening of children's hips (at a time interval of 10 years) in the Central Bohemian Region revealed certain improvement in covering children's gonads (in the frequency of using protective devices), in the protection of the accompanying person and the equipment of the workplaces with modern X-ray apparatus and automatic developers. Large differences between individual workplaces were seen in the selection of technical parameters (voltage, power, focus, size of irradiated field); that is why up to nine-fold differences existed in irradiation of children. (The mean gonadal dose was 22.6 μGy and the mean weighted whole-body dose was 71.2 μGy.) A conservative estimate of the effective dose equivalent was used in comparing the social cost and benefit in preventive screening of children's hips which had shown that at least one preventive X-ray picture in all children in the 3rd to 4th month after birth was quite reasonable. The analysis of the problems outlined revealed that particular attention must be paid to the protection of the children's gonads by using suitable protective devices and to minimize irradiation of children by a suitable adjustment of technical parameters of the examination and also by exclusive use of quality film material. (author). 4 tabs., 18 refs

  2. Nuclear reactor safety protection device

    International Nuclear Information System (INIS)

    Okido, Fumiyasu; Noguchi, Atomi; Matsumiya, Shoichi; Furusato, Ken-ichiro; Arita, Setsuo.

    1994-01-01

    The device of the present invention extremely reduces a probability of causing unnecessary scram of a nuclear reactor. That is, four control devices receive signals from each of four sensors and output four trip signals respectively in a quardruplicated control device. Each of the trip signals and each of trip signals via a delay circuit are inputted to a logical sum element. The output of the logical sum circuit is inputted to a decision of majority circuit. The decision of majority circuit controls a scram pilot valve which conducts scram of the reactor by way of a solenoid coils. With such procedures, even if surge noises of a short pulse width are mixed to the sensor signals and short trip signals are outputted, there is no worry that the scram pilot valve is actuated. Accordingly, factors of lowering nuclear plant operation efficiency due to erroneous reactor scram can be reduced. (I.S.)

  3. Advertising Via Mobile Terminals - Delivering Context Sensitive and Personalized Advertising While Guaranteeing Privacy

    Science.gov (United States)

    Bulander, Rebecca; Decker, Michael; Schiefer, Gunther; Kölmel, Bernhard

    Mobile terminals like cellular phones and PDAs are a promising target platform for mobile advertising: The devices are widely spread, are able to present interactive multimedia content and offer as almost permanently carried along personal communication devices a high degree of reachability. But particular because of the latter feature it is important to pay great attention to privacy aspects and avoidance of spam-messages when designing an application for mobile advertising. Furthermore the limited user interface of mobile devices is a special challenge. The following article describes the solution approach for mobile advertising developed within the project MoMa, which was funded by the Federal Ministry of Economics and Labour of Germany (BMWA). MoMa enables highly personalized and context sensitive mobile advertising while guaranteeing data protection. To achieve this we have to distinguish public and private context information.

  4. Social marketing campaign promoting the use of respiratory protection devices among farmers.

    Science.gov (United States)

    Pounds, Lea; Duysen, Ellen; Romberger, Debra; Cramer, Mary E; Wendl, Mary; Rautiainen, Risto

    2014-01-01

    This article describes the formal use of marketing concepts in a systematic approach to influence farmers to voluntarily increase respiratory protective device (RPD) use. The planning process for the project incorporated six key decision or action points, each informed by formative research or health behavior theory. The planning process included developing behavior change strategies based on a 4P model (product, price, place, and promotion). The resulting campaign elements included print and e-mail messages that leveraged motivators related to family and health in order to increase farmers' knowledge about the risks of exposure to dusty environments, four instructional videos related to the primary barriers identified in using RPDs, and a brightly colored storage bag to address barriers to using RPDs related to mask storage. Campaign implementation included a series of e-mails using a bulk e-mail subscription service, use of social media in the form of posting instructional videos on a YouTube channel, and in-person interactions with members of the target audience at farm shows throughout the Central States Center for Agricultural Safety and Health seven-state region. Evaluation of the e-mail campaigns indicated increased knowledge about RPD use and intent to use RPDs in dusty conditions. YouTube analytic data indicated continuing exposure of the instructional videos beyond the life of the campaign. The project demonstrates the efficacy of a planning process that incorporates formative research and clear decision points throughout. This process could be used to plan health behavior change interventions to address other agriculture-related health and safety issues.

  5. On-field evaluation of operator lens protective devices in interventional radiology

    International Nuclear Information System (INIS)

    Strocchi, S.; Chiaravalli, A.; Veronese, I.; Novario, R.

    2016-01-01

    The recent publication of the Euratom Directive 2013/59, adopting the reduction of eye lens dose limits from 150 to 20 mSv y"-"1, calls for the development of new tools and methodologies for evaluating the eye lens dose absorbed by the medical staff involved in interventional radiology practices. Moreover, the effectiveness of the protective devices, like leaded glasses, which can be employed for radiation protection purposes, must be tested under typical exposure scenarios. In this work, eye lens dose measurements were carried out on an anthropomorphic phantom simulating a physician bound to perform standard interventional neuroradiology angiographic procedures. The correlation between eye lens doses, in terms of Hp(0.07), and the equivalent dose [again in terms of Hp(0.07)] monthly measured with thermoluminescent dosemeters placed above the lead apron at the chest level was studied, in the presence and in the absence of different types of leaded glasses. (authors)

  6. Plasma sprayed TiC coatings for first wall protection in fusion devices

    International Nuclear Information System (INIS)

    Groot, P.; Laan, J.G. van der; Laas, L.; Mack, M.; Dvorak, M.

    1989-01-01

    For protection of plasma facing components in nuclear fusion devices thick titanium carbide coatings are being developed. Coatings have been produced by plasma spraying at atmospheric pressure (APS) and low pressure (LPPS) and analyzed with respect to microstructure and chemical composition. Thermo-mechanical evaluation has been performed by applying short pulse laser heat flux tests. The influence of coating thickness and porosity on the resistance to spalling by thermal shocks appears to be more important than aspects of chemical composition. (author)

  7. Safety of nursing staff and determinants of adherence to personal protective equipment

    OpenAIRE

    Neves,Heliny Carneiro Cunha; Souza,Adenícia Custódia Silva e; Medeiros,Marcelo; Munari,Denize Bouttelet; Ribeiro,Luana Cássia Miranda; Tipple,Anaclara Ferreira Veiga

    2011-01-01

    A qualitative study conducted in a teaching hospital with 15 nursing professionals. Attempted to analyze the reasons, attitudes and beliefs of nursing staff regarding adherence to personal protective equipment. Data were collected through focus groups, analyzed by the method of interpretation of meanings, considering Rosenstock’s model of health beliefs as a reference framework. Data revealed two themes: Occupational safety and Interpersonal Relationship. We identified several barriers that i...

  8. "Insensitive" to touch: fabric-supported lubricant-swollen polymeric films for omniphobic personal protective gear.

    Science.gov (United States)

    Damle, Viraj G; Tummala, Abhishiktha; Chandrashekar, Sriram; Kido, Cassidee; Roopesh, Ajay; Sun, Xiaoda; Doudrick, Kyle; Chinn, Jeff; Lee, James R; Burgin, Timothy P; Rykaczewski, Konrad

    2015-02-25

    The use of personal protective gear made from omniphobic materials that easily shed drops of all sizes could provide enhanced protection from direct exposure to most liquid-phase biological and chemical hazards and facilitate the postexposure decontamination of the gear. In recent literature, lubricated nanostructured fabrics are seen as attractive candidates for personal protective gear due to their omniphobic and self-healing characteristics. However, the ability of these lubricated fabrics to shed low surface tension liquids after physical contact with other objects in the surrounding, which is critical in demanding healthcare and military field operations, has not been investigated. In this work, we investigate the depletion of oil from lubricated fabrics in contact with highly absorbing porous media and the resulting changes in the wetting characteristics of the fabrics by representative low and high surface tension liquids. In particular, we quantify the loss of the lubricant and the dynamic contact angles of water and ethanol on lubricated fabrics upon repeated pressurized contact with highly absorbent cellulose-fiber wipes at different time intervals. We demonstrate that, in contrast to hydrophobic nanoparticle coated microfibers, fabrics encapsulated within a polymer that swells with the lubricant retain the majority of the oil and are capable of repelling high as well as low surface tension liquids even upon multiple contacts with the highly absorbing wipes. The fabric supported lubricant-swollen polymeric films introduced here, therefore, could provide durable and easy to decontaminate protection against hazardous biological and chemical liquids.

  9. Is prevention of acute pesticide poisoning effective and efficient, with Locally Adapted Personal Protective Equipment? A randomized crossover study among farmers in Chitwan, Nepal

    DEFF Research Database (Denmark)

    Varma, Anshu; Neupane, Dinesh; Bonde, Jens Peter Ellekilde

    2016-01-01

    Background: Farmers' risk of pesticide poisoning can be reduced with personal protective equipment but in low-income countries farmers' use of such equipment is limited. Objective: To examine the effectiveness and efficiency of Locally Adapted Personal Protective Equipment to reduce organophosphate...... exposure among farmers. Methods: In a crossover study, 45 male farmers from Chitwan, Nepal, were randomly allocated to work as usual applying organophosphate pesticides wearing Locally Adapted Personal Protective Equipment or Daily Practice Clothing. For seven days before each experiment, each farmer.......08; 0.06]. Wearing the Locally Adapted Personal Protective Equipment versus Daily Practice Clothing gave the following results, respectively: comfort 75.6% versus 100%, sense of heat 64.4% versus 31.3%, other problems 44.4% versus 33.3%, like-ability 95.6% versus 77.8%. Conclusion: We cannot support...

  10. Sustainable Product: Personal Protective Equipment Manufactured with Green Plastic

    Directory of Open Access Journals (Sweden)

    Hamilton Aparecido Boa Vista

    2015-04-01

    Full Text Available This study analyzed the case of manufacturing of Personal Protective Equipment (PPE using as raw material biopolymers produced from ethanol from sugar cane, known as green polypropylene, produced since 2008 by BRASKEM. This article studied the PPE for the employee’s head protection, named helmet by NR 6, which is used in situations of exposure to weather and work scenarios in places where there is risk of impact from falling or projecting objects, burns, electric shock, and solar radiation. The MSA, green helmet manufacturer, made an inventory of greenhouse gas emissions into the atmosphere by comparing the two manufacturing processes of the helmet shell, covering the January 1 to December 31, 2011 period. It concluded that the sustainable helmet (green polyethylene and pigments robs 231g of CO2 from the atmosphere per produced unit, while the helmet’s production with traditional raw materials (polyethylene and petrochemical pigments found that, for each unit produced, 1029g of CO2 are emitted into the atmosphere. The study showed that substitution of raw materials has led to reduction in the impact generated in the helmets’ production.

  11. Interacting with a personal wearable device

    NARCIS (Netherlands)

    Haan, de G.; Wright, P.; Hollnagel, E.; Dekker, S.

    2000-01-01

    Comris is a research project that aims to create a wearable assistant, "the parrot", for conference and workshop visitors. A personal interest profile and an active badge system enable agents in a virtual information space to provide context-sensitive information about interesting persons and events

  12. Hybrid Paradigm from European and America Concerning Privacy and Personal Data Protection in Indonesia

    Directory of Open Access Journals (Sweden)

    Edmon Makarim

    2013-05-01

    Full Text Available In the emerging era of information and technology, the importance of privacy and data protection is growing ever since. However, despite such common concern from the society, there is some confusion about the mechanisms of differentiation and scope of discussion about privacy with the protection of personal data and even impressed blended with issues of spamming issues. With comparison to Europe and the US legal perspectives, Therefore, this paper tries to discuss such problem in accordance to the perspective of laws to the communication itself.

  13. Improvement of the protection devices for JT-60U LHRF antenna system

    International Nuclear Information System (INIS)

    Suzuki, Sadaaki; Seki, Masami; Shinozaki, Shinichi; Sato, Fumiaki; Hiranai, Shinichi; Hasegawa, Koichi; Moriyama, Shinichi; Ishii, Kazuhiro

    2007-09-01

    In the experiments featuring lower hybrid range of frequency (LHRF) system in JT-60U, carbon grills were attached to the plasma-facing part of the antenna in order to avoid the damage by the excessive heat load from the plasma. However some electric discharge traces were found there in the observation after the experiments. To avoid such discharges, improvements of the arc detector and the protection interlock by visible picture detection were tackled. In the arc detector, the amplification circuit was improved in order to obtain shorter response time and higher resolution of optical detection. Moreover, in visible picture detection, a new function of RF-on/off control utilizing PC image processing was added to distinguish the light of the arc from one of the plasma. This report summarizes improvement of the protection interlock device in a LHRF heating system. (author)

  14. Perception and personal protective measures toward mosquito bites by communities in Jaffna District, northern Sri Lanka.

    Science.gov (United States)

    Surendran, S N; Kajatheepan, A

    2007-06-01

    Mosquito-borne diseases are of public health importance in war-torn northern Sri Lanka. The severity of mosquito bites and attitudes of the public toward mosquito problems were investigated using a structured questionnaire among communities in 3 administrative divisions in Jaffna District. One hundred fifty-four households were interviewed during this study. Sixty-four percent of the respondents reported that the mosquito problem was severe in their localities. Fifty-two percent stated that mosquito-biting activity was severe in the evening (1500 h-1900 h), 41% at night (after 1900 h), and 7% throughout the day. Severity of mosquito menace was found to have no association with type of house construction. Seventy-seven percent were able to name at least 1 disease transmitted by mosquitoes. Statistical analysis showed no association between education level and public awareness on mosquito-borne diseases. Nearly 88% were able to identify at least a breeding source of mosquitoes and most of them practice measures to eliminate suitable environments for mosquito breeding. Ninety-six percent used personal protective measures against mosquito bites during some seasons or throughout the year. Mosquito coils were the most commonly used personal protective method followed by bed nets. The monthly expenditure for personal protective measures varied from US$0.19 (LKR 20) to US$3.40 (LKR 350).

  15. The Civil Identity Registry Unification and Personal Data Protection in Brazil

    Directory of Open Access Journals (Sweden)

    José Renato Gaziero Cella

    2016-06-01

    . Article search thus demonstrate, through hypothetical-deductive method, the urgency of adopting a specific law on the protection of personal data in Brazil. To this end, it comes to point out that privacy and forms of protection are usually aligned with the technology available in each season and, with the advent of so-called Information Society captained especially the Internet and the instant and ubiquitous circulation of data it provides. The article demonstrates that even public agencies, such as the Sirc, respect the constitutional principles aimed at protecting the privacy of citizens, a fact that confirms and justifies the initial hypothesis of this work, which is, as stated, the demonstration of urgency the institution in Brazil, a specific law on personal data protection.

  16. Control and prevention of healthcare-associated tuberculosis: the role of respiratory isolation and personal respiratory protection.

    Science.gov (United States)

    Humphreys, H

    2007-05-01

    Although the prevalence of tuberculosis continues to decline in most developed countries, the risk of healthcare-associated tuberculosis, remains for patients or healthcare staff. Outbreaks of healthcare-associated tuberculosis are usually associated with delays in diagnosis and treatment, or the care of patients in sub-optimal facilities. The control and prevention of tuberculosis in hospitals is best achieved by three approaches, namely administrative (early investigation diagnosis, etc.), engineering (physical facilities e.g. ventilated isolation rooms) and personal respiratory protection (face sealing masks which are filtered). Recent guidelines on the prevention of tuberculosis in healthcare facilities from Europe and the USA have many common themes. In the UK, however, negative pressure isolation rooms are recommended only for patients with suspected multi-drug resistant TB and personal respiratory protection, i.e. filtered masks, are not considered necessary unless multi-drug resistant TB is suspected, or where aerosol-generating procedures are likely. In the US, the standard of care for patients with infectious tuberculosis is a negative pressure ventilated room and the use of personal respiratory protection for all healthcare workers entering the room of a patient with suspected or confirmed tuberculosis. The absence of clinical trials in this area precludes dogmatic recommendations. Nonetheless, observational studies and mathematical modelling suggest that all measures are required for effective prevention. Even when policies and facilities are optimal, there is a need to regularly review and audit these as sometimes compliance is less than optimal. The differences in recommendations may reflect the variations in epidemiology and the greater use of BCG vaccination in the UK compared with the United States. There is a strong argument for advising ventilated facilities and personal respiratory protection for the care of all patients with tuberculosis, as

  17. Cerebral Ischemia Detected with Diffusion-Weighted MR Imaging after Protected Carotid Artery Stenting: Comparison of Distal Balloon and Filter Device

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Suk Jung; Jeon, Pyoung [Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Roh, Hong Gee [Konkuk University Hospital, Seoul (Korea, Republic of)] (and others)

    2007-08-15

    The aim of this study was to examine the incidence of ischemia during protected carotid artery stenting (CAS) as well as to compare the protective efficacy of the balloon and filter devices on diffusion-weighted MR imaging (DWI). Seventy-one consecutive protected CAS procedures in 70 patients with a severe (> 70%) or symptomatic moderate (> 50%) carotid artery stenosis were examined. A balloon device (PercuSurge GuardWire) and a filter device (FilterWire EX/EZ, Emboshield) was used in 33 cases (CAS-B group) and 38 cases (CAS-F group) to prevent distal embolization, respectively. All the patients underwent DWI within seven days before and after the procedures. The number of new cerebral ischemic lesions on the post-procedural DWI were counted and divided into ipsilateral and contralateral lesions according to the relationship with the stenting side. New cerebral ischemic lesions were detected in 13 (39.4%) out of the 33 CAS-Bs and in 15 (39.5%) out of the 38 CAS-Fs. The mean number of total, ipsilateral and contralateral new cerebral ischemic lesion was 2.39, 1.67 and 0.73 in the CAS-B group and 2.11, 1.32 and 0.79 in the CAS-F group, respectively. No statistical differences were found between the two groups (p = 0.96, 0.74 and 0.65, respectively). The embolic complications encountered included two retinal infarctions and one hemiparesis in the CAS-B group (9.09%), and one retinal infarction, one hemiparesis and one ataxia in the CAS-F group (7.89%). There was a similar incidence of embolic complications in the two groups (p 1.00). The type of distal protection device used such as a balloon and filter does not affect the incidence of cerebral embolization after protected CAS.

  18. NCTA v. FCC - Do Commercial Free Speech Justifications Trump Consumers' Personal Data Protection Rights? Answer To Shape Mobile Advertising Industry

    DEFF Research Database (Denmark)

    Cleff, Evelyne Beatrix; King, Nancy J.

    2010-01-01

    telecommunication carriers' personal data sharing practices in order to protect their customers' data privacy when the regulation restricts use of the data for marketing purposes. In this case National Cable and Telecommunications Association (NCTA) challenged a new Federal Communications Commission (FCC) rule...... requiring carriers to obtain customers' advance approval before releasing their telephone record information for marketing purposes. NCTA claimed the FCC's new opt-in rule violates companies' First Amendment right to engage in commercial speech. At stake in this appeal was the constitutionally required...... balance between protecting consumers' information privacy in an era of pervasive data processing and protecting the rights of marketers to engage in protected commercial free speech that involves using customers' personal information. A ruling against the FCC would have limited the use of government...

  19. Risk and protective factors of different functional trajectories in older persons : Are these the same?

    NARCIS (Netherlands)

    Kempen, G.I.; Ranchor, A.V.; van Sonderen, E.; van Jaarsveld, C.H.; Sanderman, R.

    We examined whether risk and protective factors of different functional trajectories were the same in 1,765 Dutch older persons. We assessed disability in 1993 and reassessed it in 2001. For 2001 as compared with 1993, we distinguished three trajectory groups: substantially poorer, somewhat poorer,

  20. Liabilities of the competent person for radiation protection

    International Nuclear Information System (INIS)

    Bizet, A.

    2008-01-01

    The article R. 4456-1 of the Labour code requires employer to appoint a competent person for radiation protection (C.P.R.). Although the prerogatives of the CPR are exercised under the responsibility of the employer, the traditional rules of questioning the liability apply to the employer as well as to the C.P.R.. For the civil liability, the object of which is to guarantee the compensation of damage by its author, but also for the criminal liability, which aims at punishing an illegal behaviour, the C.P.R. does not escape these traditional rules which, however, apply in a particular way considering the daily missions of the C.P.R.. If the responsibility of the employer is more questioned, notably because of the authority he/she exercises on his/her employee, the C.P.R. must not be considered as irresponsible regarding civil and penal requirements; the C.P.R. may indeed be questioned by an employee victim of damage. The activity of the C.P.R. (and thus the cases allowing the questioning of its liability) rests widely on the means which it has and the context in which it discharges its missions. Moreover the judge does take into account the resources which an agent has to judge his responsibility. Thus, the relations of the C.P.R. with other actors of the radiation protection, internal or external in the establishment, are determining. (author)

  1. Evaluation of radiation protection in x rays room design in diagnostic radiography department in Omdurman locality

    International Nuclear Information System (INIS)

    Adam, Ahmed yusif Abdelrahman

    2013-03-01

    The purpose of this study is conducted in order to evaluate the application of radiation protection in x-ray rooms design in diagnosis radiology department, evaluate personal monitoring devices, to assess primary scatter and leakage radiation dose, to assess monitoring devices if available, in period from March 2013 to August 2013. The design data included room size, control room size, manufacture of equipment, room surrounding areas, workload of all equipment rooms, type of x-ray equipment, radiation worker's in all hospital, number of patient in each shift, structural material and shielding, K vp and m As used in x-ray room department during examination testing. The results of this study show that there is x-ray room design, the design of x-ray equipment is accepted according to the radiation safety institute team of quality control. Also the study shows that the radiation protection devices are available and in a good condition and enough in number. The study shows that there are not personal monitoring devices and services. the radiological technologist are well trained. Also the study investigation the radiation protection in x-ray room in diagnostic department in Omdurman locality. Finally the study shows that there is compact able to ICRP recommended and National quality control in Sudan Atomic Energy Council exception, Alwedad, Abusied and Blue Nile there are have not control room concludes that there is only in relationship hospital have a window without shield.(Author)

  2. Draft guidance notes for the protection of persons against ionising radiations arising from veterinary use

    International Nuclear Information System (INIS)

    1983-01-01

    These guidance notes have been prepared for those who use ionising radiation for diagnostic purposes in veterinary practice, either in private practices or in larger institutions. Ancillary activities such as the testing and calibration of equipment are also covered by these notes so far as they are carried out on the same premises. The guidance notes indicate procedures for the protection of all persons who may be exposed as a result of these practices, that is to say all employed and self-employed persons, apprentices and students, and members of the public. (author)

  3. Hostility and hearing protection behavior: the mediating role of personal beliefs and low frustration tolerance.

    Science.gov (United States)

    Rabinowitz, S; Melamed, S; Feiner, M; Weisberg, E; Ribak, J

    1996-10-01

    The authors examined whether hostility would negatively be associated with occupational health behavior, namely, the use of hearing protection devices (HPDs). Also examined as possible mediators were the protection motivation theory (PMT) components and low frustration tolerance (LFT). Participants were 226 male industrial workers, all exposed to potentially hearing-damaging noise. Hostility was negatively related to HPD use. It moderately correlated with the PMT components: negatively with perceived susceptibility, severity, effectiveness, and self-efficacy and positively with perceived barriers. Hostility correlated highly with LFT. Regression analyses confirmed the mediating role of perceived barriers, low self-efficacy, and LFT in the negative relationship between hostility and the use of HPDs. Thus, intrapsychic characteristics of hostile people may be significant for hearing protection behavior.

  4. Protective coatings for in-vessel fusion devices

    International Nuclear Information System (INIS)

    Brossa, F.

    1984-01-01

    Coatings of Al/Si, SAP (Sintered Aluminium Powder), Al 2 O 3 , TiC (low-Z material) and Ta have been developed for in-vessel component protection. Anodic oxidation, vapor depositions, reactive sputtering, chemical vapor deposition (CVD) and plasma spray have been the coating formation methods studied. AISI 316, 310, 304, Inconel 600 and Mo were adopted as base materials. the coatings were characterized in terms of composition, structure and connection with the supporting material. The behavior of coatings under H + , D + and He + irradiation in the energy range 100 eV-8 keV was tested and compared to the solid massive samples. TiC and Ta coatings were tested with thermal shock under power density pulses of 1 kW/cm 2 generated by an electron beam gun. Temperature-dependence of the erosion of TiC by vacuum arcs in a magnetic field was also studied. TiC coatings have low sputtering values, good resistance to arcing and a high chemical stability. TiC and Ta, CVD and plasma spray coatings are thermal-shock resistant. High thermal loads produce cracks but no spalling. Destruction occurred only after melting of the base material. The plasma spray coating method seems to be most appropriate for developing remote handling applications in fusion devices. (orig.)

  5. Robust sleep quality quantification method for a personal handheld device.

    Science.gov (United States)

    Shin, Hangsik; Choi, Byunghun; Kim, Doyoon; Cho, Jaegeol

    2014-06-01

    The purpose of this study was to develop and validate a novel method for sleep quality quantification using personal handheld devices. The proposed method used 3- or 6-axes signals, including acceleration and angular velocity, obtained from built-in sensors in a smartphone and applied a real-time wavelet denoising technique to minimize the nonstationary noise. Sleep or wake status was decided on each axis, and the totals were finally summed to calculate sleep efficiency (SE), regarded as sleep quality in general. The sleep experiment was carried out for performance evaluation of the proposed method, and 14 subjects participated. An experimental protocol was designed for comparative analysis. The activity during sleep was recorded not only by the proposed method but also by well-known commercial applications simultaneously; moreover, activity was recorded on different mattresses and locations to verify the reliability in practical use. Every calculated SE was compared with the SE of a clinically certified medical device, the Philips (Amsterdam, The Netherlands) Actiwatch. In these experiments, the proposed method proved its reliability in quantifying sleep quality. Compared with the Actiwatch, accuracy and average bias error of SE calculated by the proposed method were 96.50% and -1.91%, respectively. The proposed method was vastly superior to other comparative applications with at least 11.41% in average accuracy and at least 6.10% in average bias; average accuracy and average absolute bias error of comparative applications were 76.33% and 17.52%, respectively.

  6. Use of remote video auditing to validate Ebola level II personal protective equipment competency.

    Science.gov (United States)

    Allar, Peter J; Frank-Cooper, Madalyn

    2015-06-01

    Faced with an Ebola-related mandate to regularly train frontline hospital staff with the donning and doffing of personal protective equipment, a community hospital's emergency department implemented remote video auditing (RVA) to assist in the training and remediation of its nursing staff. RVA was found to be useful in assessing performance and facilitating remediation. Copyright 2015, SLACK Incorporated.

  7. Fourth meeting of persons competent in radiation protection

    International Nuclear Information System (INIS)

    David, C.; Vidal, J.P.; Ammerich, M.; Feron, F.; Pasquier, J.L.; Lecomte, J.F.; Mansoux, H.; Menechal, Ph.; Briand-Champlong, J.; Gambini, D.J.; Bontemps, A.; Frobert, F.; Grandclaude, A.; Fraboulet, P.; Laporte, Ch.; Roussille, F.; Lahaye, Th.

    2005-01-01

    The different contributions are as follow: the landscape of radiation sources in France; decrees: general presentation; relation of the person competent in radiation protection (P.C.R.) with officials organisms: the part of the D.G.S.N.R.; relation of the P.C.R. with the official organisms: the part of I.R.S.N.; authorizations: industry, education, research; interlocutors of the P.C.R. in hospitals; enforcement of the decree relative to the training of the P.C.R. at the I.N.S.T.N.; the educational contribution of the P.C.R.; European equivalence of the P.C.R. synthesis of training, comparison to the French situation; P.C.R.: contribution, missions and means in the industrial medium; management of damaged situations by the P.C.R.: contribution of the training and the putting in position; coordination with the exterior companies and prevention plans out of I.N.B.; regulatory evolution. (N.C.)

  8. Training in radiation protection

    International Nuclear Information System (INIS)

    Schreiber, F.

    1998-01-01

    Persons who are exposed to ionizing radiation at their workplace have to be trained in radiation protection. According to the Radiation Protection Ordinance the person with responsibility in radiation protection has to guarantee that the training is performed twice a year. Our training material was created especially for the persons defined in the Radiation Protection Ordinance and the X-ray Ordinance. It enables persons who teach (generally the radiation protection officer) to perform the training without tedious study and preparation of the documents. Our material is not just another textbook for radiation protection but rather a folder with colour transparencies and explanatory texts which make a difference in volume and price in comparison to other existing materials. (orig.) [de

  9. Medical Devices; General Hospital and Personal Use Devices; Classification of the Ultraviolet Radiation Chamber Disinfection Device. Final order.

    Science.gov (United States)

    2015-11-20

    The Food and Drug Administration (FDA or the Agency) is classifying the ultraviolet (UV) radiation chamber disinfection device into class II (special controls). The special controls that will apply to the device are identified in this order and will be part of the codified language for the UV radiation chamber disinfection device classification. The Agency is classifying the device into class II (special controls) in order to provide a reasonable assurance of safety and effectiveness of the device.

  10. CONCEPTUAL BASES OF FORMING THE SYSTEM OF FINANCIAL AND ECONOMIC PROVIDING SOCIAL PROTECTION INVOLUNTARILY DISPLACED PERSONS WITH CLUSTER APPROACH

    Directory of Open Access Journals (Sweden)

    Svitlana Kropelnytska

    2017-08-01

    Full Text Available The article systematizes approaches to financial support and social adaptation of internally displaced persons (IDPs as well as their social protection, that is based on the analysis of legal framework, situation and sources of financial and social support to the EU member states of the IDPs in Ukraine and their social security. The study of the IDPs situation and the assessment of the required resources are based on a cluster approach, which defines optimal set of problem areas requiring priority social and financial support. This allowed to develop practical recommendations for the development of a comprehensive, transparent and unified policy of social protection through the development of a conceptual framework for the financial and economic provision of social protection IDPs, which will be the basic solution to the problems of social and financial provision forced migrants in Ukraine. Key words: forced migrants, internally displaced persons, cluster, social policy, social protection, social providing, financial providing.

  11. An audiovisual feedback device for compression depth, rate and complete chest recoil can improve the CPR performance of lay persons during self-training on a manikin

    International Nuclear Information System (INIS)

    Krasteva, Vessela; Jekova, Irena; Didon, Jean-Philippe

    2011-01-01

    This study aims to contribute to the scarce data available about the abilities of untrained lay persons to perform hands-only cardio-pulmonary resuscitation (CPR) on a manikin and the improvement of their skills during training with an autonomous CPR feedback device. The study focuses on the following questions: (i) Is there a need for such a CPR training device? (ii) How adequate are the embedded visual feedback and audio guidance for training of lay persons who learn and correct themselves in real time without instructor guidance? (iii) What is the achieved effect of only 3 min of training? This is a prospective study in which 63 lay persons (volunteers) received a debriefing to basic life support and then performed two consecutive 3 min trials of hands-only CPR on a manikin. The pre-training skills of the lay persons were tested in trial 1. The training process with audio guidance and visual feedback from a cardio compression control device (CC-Device) was recorded in trial 2. After initial debriefing for correct chest compressions (CC) with rate 85–115 min −1 , depth 3.8–5.4 cm and complete recoil, in trial 1 the lay persons were able to perform CC without feedback at mean rate 95.9 ± 18.9 min −1 , mean depth 4.13 ± 1.5 cm, with low proportions of 'correct depth', 'correct rate' and 'correct recoil' at 33%, 43%, 87%, resulting in the scarce proportion of 14% for compressions, which simultaneously fulfill the three quality criteria ('correct all'). In trial 2, the training process by the CC-Device was established by the significant improvement of the CC skills until the 60th second of training, when 'correct depth', 'correct rate' and 'correct recoil' attained the plateau of the highest quality at 82%, 90%, 96%, respectively, resulting in 73% 'correct all' compressions within 3 min of training. The training was associated with reduced variance of the mean rate 102.4 ± 4

  12. Design And Development Of An Automatic Single Phase Protective Device Using Ssr

    Directory of Open Access Journals (Sweden)

    Michael E.

    2017-10-01

    Full Text Available Since the discovery of energy safety has been a paramount subject matter. This we can see in todays electrical systems where protective devices such as fuse and circuit breakers are used to prevent fire hazards resulting from overload overvoltage and short circuits. However with all the revolution in technology these options may be considered less smart since the fuse made with wire strands calculated for specific current capacity faults permanently when the specified current rating is exceeded. While the circuit breaker which is made up of mechanical switch fails as a result of carbon forming and the wearing away of the contacts because of arcing. As a means of improvement this paper presents the design and development of an automatic single phase protective device using solid state relay SSR. This study is to ensure automatic cut off from power supply in cases of overvoltage above 240 V AC or when overload and short circuit current above 8amps is detected without permanent damage of a fuse placed along current path. Also the design will ensure that there is an automatic close circuit whenever the trigger switch is momentary switch is closed. The system is achieved via the use of PIC micro-controller current sensor and other discrete components. The system is tested and works well inhibiting the frequent faulting of fuses. It also helps to prevent hazard as a result of overvoltage overload and short circuit and ensures a close circuit when the trigger switch is closed.

  13. Endovascular rescue of a fused monorail balloon and cerebral protection device.

    Science.gov (United States)

    Campbell, John E; Bates, Mark C; Elmore, Michael

    2007-08-01

    To present a case of successful endovascular retrieval of a monorail predilation balloon fused to an embolic protection device (EPD) in the distal internal carotid artery (ICA) of a high-risk symptomatic patient. A 60-year-old man with documented systemic atherosclerotic disease had a severe (>70%) restenosis in the left ICA 3 years after endarterectomy. He was scheduled for carotid artery stenting (CAS) with cerebral protection; however, he developed unstable angina and was transferred to our facility, where the admitting team decided that staged CAS followed by coronary bypass grafting would be the best option. During the CAS procedure, a 6-mm AccuNet filter was passed across the lesion via a 6-F carotid sheath and deployed in the distal ICA without incident. However, the 4-x20-mm predilation monorail balloon was then advanced without visualizing the markers, resulting in inadvertent aggressive interaction that trapped the balloon's tip in the filter. Several maneuvers to separate the devices were unsuccessful. Finally, the filter/balloon combination was moved gently retrograde until the balloon was straddling the subtotal ICA lesion. The lesion was dilated to 4 mm with the balloon, and the sheath was gently advanced across the lesion as the balloon was deflated. Angiography excluded interval occlusion of the filter from the embolic debris during the aforementioned aggressive maneuvers and documented antegrade flow. The filter was slowly withdrawn into the 6-F sheath with simultaneous aspiration. A second 6-mm filter was deployed, and the procedure was completed satisfactorily. The patient did well, with no neurological sequelae. EPDs are an essential in carotid artery stenting and, keeping in mind the potential risks associated with their use, will help the operator avoid complications such as this one.

  14. Privacy Protection in Personal Health Information and Shared Care Records

    Directory of Open Access Journals (Sweden)

    Roderick L B Neame

    2014-03-01

    Full Text Available Background The protection of personal information privacy has become one of the most pressing security concerns for record keepers. Many institutions have yet to implement the essential infrastructure for data privacy protection and patient control when accessing and sharing data; even more have failed to instil a privacy and security awareness mindset and culture amongst their staff. Increased regulation, together with better compliance monitoring has led to the imposition of increasingly significant monetary penalties for failures to protect privacy. Objective  There is growing pressure in clinical environments to deliver shared patient care and to support this with integrated information.  This demands that more information passes between institutions and care providers without breaching patient privacy or autonomy.  This can be achieved with relatively minor enhancements of existing infrastructures and does not require extensive investment in inter-operating electronic records: indeed such investments to date have been shown not to materially improve data sharing.Requirements for Privacy  There is an ethical duty as well as a legal obligation on the part of care providers (and record keepers to keep patient information confidential and to share it only with the authorisation of the patient.  To achieve this information storage and retrieval, and communication systems must be appropriately configured. Patients may consult clinicians anywhere and at any time: therefore their data must be available for recipient-driven retrieval under patient control and kept private. 

  15. PERSONA : a personalized data protection framework

    NARCIS (Netherlands)

    Egea, M.; Paci, F.; Petrocchi, M.; Zannone, N.; Fernández-Gago, C.; Martinelli, F.; Pearson, S.; Agudo, I.

    2013-01-01

    The European Directive on Data Protection recognizes the right of data subjects to control the usage of their information. However, to date there are no data protection solutions that involve data subjects in the definition and enforcement of data protection policies. In this paper we present the

  16. Fire protection devices in the controlled region of GKN nuclear power station

    International Nuclear Information System (INIS)

    Bernhardt, S.; Grauf, E.

    1976-01-01

    In the GKN nuclear power station ('Neckar reactor'), an 805 MW PWR reactor whose start-up is scheduled for the near future, fire protection measures have been realized that go far beyond those realized in other German nuclear power stations until now. One of the main reasons is that the authorities have been sensibilized by a fire in the refuelling cavity during construction and by the Browns Ferry fire and are therefore extremely thorough in their examination. Further subsections have been added to the fire prevention sections in order to provide better quenching devices for potential fire sites. (orig./AK) [de

  17. Security Hi-tech Individual Extra-light Device Mask: a new protection for [soccer] players.

    Science.gov (United States)

    Cascone, Piero; Petrucci, Bernardino; Ramieri, Valerio; Marianetti, Titto Matteo; TitoMatteo, Marianetti

    2008-05-01

    Among professional [soccer] players, a relevant incidence of maxillofacial trauma has been reported. The main challenge in these particular patients is to give them the possibility of a very short convalescence period and to make possible their agonistic activity as soon as possible. The authors here present an innovative technique to realize this--the Security Hi-tech Individual Extra-Light Device Mask, a customizable protective shield based on the player's face cast. A completely customized mask was forged over the player's face cast to protect the injured area. This mask shortens convalescence period, and due to its realization, it is comfortable and easy fitting, thus allowing the player to perform at a professional level in his sport activity in the shortest time possible.

  18. Reflex Marine celebrates 10. anniversary of FROG crew transfer device

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2010-07-15

    Reflex Marine developed the initial 3-person FROG crew transfer device in response to the main risks identified from incidents involving traditional rope baskets for personnel transfer: falling, collisions, hard landings, and immersion. To address these issues, the FROG was developed with 4-point harnesses, a protective shell, shock-absorbing landing feet, and self-righting capability. As a result of industry demand for a higher capacity transfer device, the company introduced 6- and 9-man versions of the FROG. The perceptions and reality of marine transfers have changed greatly over the past decade, from the design of the device to vessel specifications and increased focus on crane operations. Marine transfers offer a low-risk alternative to helicopter transfers. The TORO, a low-cost crew transfer capsule launched in February 2009, fits into a standard shipping container, providing significant logistical advantages. The TORO can carry 4 passengers, offer protection from side impacts and hard landings, and is buoyant and self-righting. Most of the units are being used by major oil and gas companies, but offshore wind turbines are an emerging source of demand for the crew transfer system. 3 figs.

  19. Application of Detailed Phase Comparison Protection Models for the Analysis of its Operation in Networks with Facts Devices

    Directory of Open Access Journals (Sweden)

    Ruban Nikolay Yu.

    2015-01-01

    Full Text Available The problem of relay protection misoperations in networks with FACTS devices is considered in the paper. It is offered a solution to this problem for a phase comparison protection of transmission power line through the use of its detailed model for the analysis of the functioning for a case of various normal, emergency and post-emergency modes of electric power systems. The research results of this approach are given in the paper.

  20. Privacy protection for personal health information and shared care records.

    Science.gov (United States)

    Neame, Roderick L B

    2014-01-01

    The protection of personal information privacy has become one of the most pressing security concerns for record keepers: this will become more onerous with the introduction of the European General Data Protection Regulation (GDPR) in mid-2014. Many institutions, both large and small, have yet to implement the essential infrastructure for data privacy protection and patient consent and control when accessing and sharing data; even more have failed to instil a privacy and security awareness mindset and culture amongst their staff. Increased regulation, together with better compliance monitoring, has led to the imposition of increasingly significant monetary penalties for failure to protect privacy: these too are set to become more onerous under the GDPR, increasing to a maximum of 2% of annual turnover. There is growing pressure in clinical environments to deliver shared patient care and to support this with integrated information. This demands that more information passes between institutions and care providers without breaching patient privacy or autonomy. This can be achieved with relatively minor enhancements of existing infrastructures and does not require extensive investment in inter-operating electronic records: indeed such investments to date have been shown not to materially improve data sharing. REQUIREMENTS FOR PRIVACY: There is an ethical duty as well as a legal obligation on the part of care providers (and record keepers) to keep patient information confidential and to share it only with the authorisation of the patient. To achieve this information storage and retrieval, communication systems must be appropriately configured. There are many components of this, which are discussed in this paper. Patients may consult clinicians anywhere and at any time: therefore, their data must be available for recipient-driven retrieval (i.e. like the World Wide Web) under patient control and kept private: a method for delivering this is outlined.

  1. Protection of occupants from exhaled infectious agents and floor material emissions in rooms with personalized and underfloor ventilation

    DEFF Research Database (Denmark)

    Cermak, Radim; Melikov, Arsen Krikor

    2007-01-01

    the concentration of exhaled air pollution increased in the room. The two types of personalized ventilation performed differently. Subsequent analyses of airborne infection transmission risk indicated that personalized ventilation could become a supplement to traditional methods of infection control....... of pollutants associated with exhaled air and floor material emissions was evaluated at various combinations of personalized and underfloor airflow rates. Compared to underfloor ventilation alone, personalized and underfloor ventilation provided excellent protection Of seated occupants from any pollution, while......The performance of two personalized. ventilation systems supplying air at the breathing zone was tested in conjunction with underfloor ventilation generating two different airflow patterns in a full-scale test room. Two breathing thermal manikins were used to simulate occupants. The distribution...

  2. Search and seizure law; practical advice and interpretation for nuclear protective force persons

    Energy Technology Data Exchange (ETDEWEB)

    Cadwell, J.J.

    1983-07-06

    Recent Supreme Court decisions, which interpret the 200-year-old Fourth Amendment of the US Constitution, are used to provide a brief overview of some search and seizure subjects important to management and officers responsible for physical protection of nuclear facilities. The overview is framed in practical terms in order to make the comments applicable to the everyday activity of nuclear-protective-force persons. The Supreme Court has described several exceptions where searches and seizures (arrests) are permitted without a warrant, despite the Fourth Amendment which states that warrants are always required. The seven exceptions briefly discussed are search incidents to a lawful arrest, the automobile-search exception, the suitcase or container exception, the hot-pursuit or emergency exception, the stop-and-frisk exception, the plain-view exception, and consent to be searched.

  3. Search and seizure law; practical advice and interpretation for nuclear protective force persons

    International Nuclear Information System (INIS)

    Cadwell, J.J.

    1983-01-01

    Recent Supreme Court decisions, which interpret the 200-year-old Fourth Amendment of the US Constitution, are used to provide a brief overview of some search and seizure subjects important to management and officers responsible for physical protection of nuclear facilities. The overview is framed in practical terms in order to make the comments applicable to the everyday activity of nuclear-protective-force persons. The Supreme Court has described several exceptions where searches and seizures (arrests) are permitted without a warrant, despite the Fourth Amendment which states that warrants are always required. The seven exceptions briefly discussed are search incidents to a lawful arrest, the automobile-search exception, the suitcase or container exception, the hot-pursuit or emergency exception, the stop-and-frisk exception, the plain-view exception, and consent to be searched

  4. Border malaria in China: knowledge and use of personal protection by minority populations and implications for malaria control: a questionnaire-based survey

    Directory of Open Access Journals (Sweden)

    Hill Nigel

    2008-10-01

    Full Text Available Abstract Background Malaria control in remote, forested areas of the Mekong region relies on personal protection from mosquito bites. Uptake of these methods may be limited by knowledge of the link between mosquitoes and malaria as well as social and economic aspects. Understanding barriers to uptake will inform malaria control programmes on targets for improvement of delivery. Methods A total 748 key respondents: health providers and village heads, from 187 villages and 25 different ethnic groups, were interviewed using structured questionnaires. Differences in use of personal protection, and knowledge of malaria between groups were analysed using chi-square; and binary logistic regression used for multivariate analysis. Results Malaria knowledge was poor with 19.4% of women and 37.5% of men linking mosquitoes with malaria, although 95.6% knew one or more methods of mosquito control. Virtually all respondents used personal protection at some time during the year; and understanding of malaria transmission was strongly associated with bednet use. Those working in forest agriculture were significantly more likely to know that mosquitoes transmit malaria but this did not translate into a significantly greater likelihood of using bednets. Furthermore, use of personal protection while woing outdoors was rare, and less than 3% of respondents knew about the insecticide impregnation of bednets. The use of bednets, synthetic repellents and mosquito coils varied between ethnic groups, but was significantly more frequent among those with higher income, more years of education and permanent housing. The reported use of repellents and coils was also more common among women despite their low knowledge of malaria transmission, and low likelihood of having heard information on malaria within the last year. Conclusion The use of personal protection must be increased, particularly among outdoor workers that have higher malaria risk. However, personal protection

  5. Border malaria in China: knowledge and use of personal protection by minority populations and implications for malaria control: a questionnaire-based survey.

    Science.gov (United States)

    Moore, Sarah J; Min, Xia; Hill, Nigel; Jones, Caroline; Zaixing, Zhang; Cameron, Mary M

    2008-10-01

    Malaria control in remote, forested areas of the Mekong region relies on personal protection from mosquito bites. Uptake of these methods may be limited by knowledge of the link between mosquitoes and malaria as well as social and economic aspects. Understanding barriers to uptake will inform malaria control programmes on targets for improvement of delivery. A total 748 key respondents: health providers and village heads, from 187 villages and 25 different ethnic groups, were interviewed using structured questionnaires. Differences in use of personal protection, and knowledge of malaria between groups were analysed using chi-square; and binary logistic regression used for multivariate analysis. Malaria knowledge was poor with 19.4% of women and 37.5% of men linking mosquitoes with malaria, although 95.6% knew one or more methods of mosquito control. Virtually all respondents used personal protection at some time during the year; and understanding of malaria transmission was strongly associated with bednet use. Those working in forest agriculture were significantly more likely to know that mosquitoes transmit malaria but this did not translate into a significantly greater likelihood of using bednets. Furthermore, use of personal protection while woing outdoors was rare, and less than 3% of respondents knew about the insecticide impregnation of bednets. The use of bednets, synthetic repellents and mosquito coils varied between ethnic groups, but was significantly more frequent among those with higher income, more years of education and permanent housing. The reported use of repellents and coils was also more common among women despite their low knowledge of malaria transmission, and low likelihood of having heard information on malaria within the last year. The use of personal protection must be increased, particularly among outdoor workers that have higher malaria risk. However, personal protection is widely used and widely accepted to prevent nuisance biting

  6. Report About a New Standard for Radiation Protection Training of Intervention Persons. In the Case of Radiological emergency Situations

    International Nuclear Information System (INIS)

    Geringer, T.; Steurer, A.; Schmitzer, C.

    2004-01-01

    In autumn 2003 the Austrian standard OENORM S 5207 with the title R adiation protection training of intervention persons in the case of radiological emergency situations w ill be published. The standard is directed to persons who have to invent in case of a radiological emergency, security forces and as well training centres. The standard has to fulfil three objectives: 1. Regulation of the minimum requirements for the radiation protection training and education of intervention persons. 2. Harmonization of the radiation protection and training of different security forces, for instance Austrian army, Red Cross Austria, Fire Department, Police Department. 3. Mutual recognition of parts of the education between the different security forces. To fulfil these aims the standard is structured in different education modules. If , for instance, a person attended a special training module at the Austrian military, this part of the education is also valid for a career at the Fire Department. Further the modular structure of the education gives the possibility for persons of a special security force to attend one or more modules at another security force. This will lead to an improved cooperation between the different security forces in case of a radiological emergency situation. The education is structured in four levels. The topics of the standard are: 1. Requirements for training centres 2. Guidelines for the examinations of the candidates 3. Topics and goals of the basic education 4. Topics and goals of the advanced education level one 5. Topics and goals of the advanced education level two 6. Topics and examples of specialised education 7. Obligatory further education once every year. (Author)

  7. Pancreatic Tissue Transplanted in TheraCyte Encapsulation Devices Is Protected and Prevents Hyperglycemia in a Mouse Model of Immune-Mediated Diabetes.

    Science.gov (United States)

    Boettler, Tobias; Schneider, Darius; Cheng, Yang; Kadoya, Kuniko; Brandon, Eugene P; Martinson, Laura; von Herrath, Matthias

    2016-01-01

    Type 1 diabetes (T1D) is characterized by destruction of glucose-responsive insulin-producing pancreatic β-cells and exhibits immune infiltration of pancreatic islets, where CD8 lymphocytes are most prominent. Curative transplantation of pancreatic islets is seriously hampered by the persistence of autoreactive immune cells that require high doses of immunosuppressive drugs. An elegant approach to confer graft protection while obviating the need for immunosuppression is the use of encapsulation devices that allow for the transfer of oxygen and nutrients, yet prevent immune cells from making direct contact with the islet grafts. Here we demonstrate that macroencapsulation devices (TheraCyte) loaded with neonatal pancreatic tissue and transplanted into RIP-LCMV.GP mice prevented disease onset in a model of virus-induced diabetes mellitus. Histological analyses revealed that insulin-producing cells survived within the device in animal models of diabetes. Our results demonstrate that these encapsulation devices can protect from an immune-mediated attack and can contain a sufficient amount of insulin-producing cells to prevent overt hyperglycemia.

  8. Effects of Personal Traits on Generation Y Consumers' Attitudes Toward the Use of Mobile Devices for Communication and Commerce

    Directory of Open Access Journals (Sweden)

    Jihyun Kim

    2012-01-01

    Full Text Available The purpose of this study was to investigate the effects of young adult consumers' personal traits (high-tech involvement, experiment proclivity, and fashion/brand leadership on their perceptions of and attitudes toward using mobile devices for communications and commerce. The integrated stimulus-organism-responses paradigm (Fiore & Kim, 2007 served as the overarching framework, combining the uses and gratifications theory (Blumler & Katz, 1974 and the extended technology acceptance model (Kim, Ma, & Park, 2009. A convenience sample of 504 college students in 2 U. S. universities provided usable responses to our survey. Causal modeling analysis results showed that personal trait variables had significant impacts on the perceived ease of use, usefulness, and enjoyment, and attitudes toward mobile communication and mobile commerce. Findings also suggested that three perception variables positively influenced attitudes toward using mobile devices for communication as well as for commerce. This study provides empirical evidence of the potential of mobile commerce among young adult consumers.

  9. Devices, Distractions and Digital Literacy: "Bring Your Own Device" to Polytech

    Science.gov (United States)

    Drew, Leoni; Forbes, Dianne

    2017-01-01

    The purpose of this study is to investigate the ways polytechnic students use personal mobile devices to support their learning. This study used purposive sampling and mixed methods to generate data about student ownership and use of mobile digital devices within a single institution. Findings reveal patterns of device ownership, insights into how…

  10. Digital protection in power plants. Electrical unit and line protection. Digital protection systems for NPP

    International Nuclear Information System (INIS)

    Kaczmarek, A.

    2000-01-01

    In this presentation author deals with the digital protection systems for nuclear power plants. The evolution of protection devices, protection concept for power plants, concept of functional redundancy, references for digital protection, benefits for the customer well as concept fault recorder are presented. (author)

  11. A fractionation of the physiological burden of the personal protective equipment worn by firefighters.

    Science.gov (United States)

    Taylor, Nigel A S; Lewis, Michael C; Notley, Sean R; Peoples, Gregory E

    2012-08-01

    Load carriage increases physiological strain, reduces work capacity and elevates the risk of work-related injury. In this project, the separate and combined physiological consequences of wearing the personal protective equipment used by firefighters were evaluated. The overall impact upon performance was first measured in 20 subjects during a maximal, job-related obstacle course trial and an incremental treadmill test to exhaustion (with and without protective equipment). The fractional contributions of the thermal protective clothing, helmet, breathing apparatus and boots were then separately determined during steady-state walking (4.8 km h(-1), 0% gradient) and bench stepping (20 cm at 40 steps min(-1)). The protective equipment reduced exercise tolerance by 56% on a treadmill, with the ambulatory oxygen consumption reserve (peak minus steady-state walking) being 31% lower. For the obstacle course, performance declined by 27%. Under steady-state conditions, the footwear exerted the greatest relative metabolic impact during walking and bench stepping, being 8.7 and 6.4 times greater per unit mass than the breathing apparatus. Indeed, the relative influence of the clothing on oxygen cost was at least three times that of the breathing apparatus. Therefore, the most efficient way to reduce the physiological burden of firefighters' protective equipment, and thereby increase safety, would be to reduce the mass of the boots and thermal protective clothing.

  12. Evaluation of radiation protection and technical procedures in Wad Madani Heart Diseases and Surgery Center (WHDSC) (cardiac catheterization laboratory)

    International Nuclear Information System (INIS)

    Gesmallah, A. H. A.

    2013-07-01

    The purpose of this study is conducted in order to evaluate the application of radiation protection program, evaluate the design of cardiac catheterization laboratory, evaluate the effectiveness of radiation protection devices, evaluate personal monitoring, usage of G-Arm x-ray machine, to evaluate the responsibilities of radiation protection officer (RPO), to assess monitoring devices if available, and to assess patient patient dose in Wad Madani hear disease and surgery center in a period from march 2013 to june 2013. The most data in this study was obtained from the results of the team of quality assurance and control of radiation safety institute when they visited hospital on 14/2/2011 for inspection and calibration for issue of registration and licenses, except the data of patients dose which obtained from exposure parameters and dosimetric information's in the archive of G-arm x-ray fluoroscopic machine (which were 110 of cardiac catheterization diagnostic and therapeutic cases, 60 of adult patients and 50 of children. The patient data included age, weight, kv, mAs, DAP, air kerma, and fluoro time. The results of this study show that there is radiation protection program need correction and partially applied, the design of cardiac catheterization laboratory is accepted according to radiation safety institute team of quality control. Also the study shows that the radiation protection program devices are available and good condition and enough in number. The study shows that there are no personal monitoring devices and services and the radiological technologist are well trained to dial with the G-arm x-ray machine and to apply the radiation protection program effectively. Also the study states that the radiation protection officer could apply his responsibilities partially. Finally the study shows that there is a direct linear relationship between the patient's weight and (DAP, air kerma, kv, and mAs) concludes that there is excessive radiation dose in cardiac

  13. A Multi-Technique Reconfigurable Electrochemical Biosensor: Enabling Personal Health Monitoring in Mobile Devices.

    Science.gov (United States)

    Sun, Alexander; Venkatesh, A G; Hall, Drew A

    2016-10-01

    This paper describes the design and characterization of a reconfigurable, multi-technique electrochemical biosensor designed for direct integration into smartphone and wearable technologies to enable remote and accurate personal health monitoring. By repurposing components from one mode to the next, the biosensor's potentiostat is able reconfigure itself into three different measurements modes to perform amperometric, potentiometric, and impedance spectroscopic tests all with minimal redundant devices. A [Formula: see text] PCB prototype of the module was developed with discrete components and tested using Google's Project Ara modular smartphone. The amperometric mode has a ±1 nA to [Formula: see text] measurement range. When used to detect pH, the potentiometric mode achieves a resolution of < 0.08 pH units. In impedance measurement mode, the device can measure 50 Ω-10 [Formula: see text] and has been shown to have of phase error. This prototype was used to perform several point-of-care health tracking assays suitable for use with mobile devices: 1) Blood glucose tests were conducted and shown to cover the diagnostic range for Diabetic patients (  ∼  200 mg/dL). 2) Lactoferrin, a biomarker for urinary tract infections, was detected with a limit of detection of approximately 1 ng/mL. 3) pH tests of sweat were conducted to track dehydration during exercise. 4) EIS was used to determine the concentration of NeutrAvidin via a label-free assay.

  14. An Energy-Efficient Virtualization-Based Secure Platform for Protecting Sensitive User Data

    Directory of Open Access Journals (Sweden)

    Kyung-Soo Lim

    2017-07-01

    Full Text Available Currently, the exchange cycles of various computers, smartphones, tablets, and others have become shorter, because new high-performance devices continue to roll out rapidly. However, existing legacy devices are not old-fashioned or obsolete to use. From the perspective of sustainable information technology (IT, energy-efficient virtualization can apply a way to increase reusability for special customized devices and enhance the security of existing legacy devices. It means that the virtualization can customize a specially designed purpose using the guest domain from obsolete devices. Thus, this could be a computing scheme that keeps energy supplies and demands in balance for future sustainable IT. Moreover, energy-efficient virtualization can be the long-term and self-sustainable solution such as cloud computing, big data and so forth. By separating the domain of the host device based on virtualization, the guest OS on the segmented domain can be used as a Trusted Execution Environment to perform security features. In this paper, we introduce a secure platform to protect sensitive user data by domain isolation utilizing virtualization. The sensitive user data on our secure platform can protect against the infringement of personal information by malicious attacks. This study is an effective solution in terms of sustainability by recycling them for special purposes or enhancing the security of existing devices.

  15. Intra- and Inter-personal Consequences of Protective Buffering among Cancer Patients and Caregivers

    Science.gov (United States)

    Langer, Shelby L.; Brown, Jonathon D.; Syrjala, Karen L.

    2009-01-01

    BACKGROUND Protective buffering refers to hiding cancer-related thoughts and concerns from one’s spouse or partner. This study sought to examine the intra- and inter-personal consequences of protective buffering and motivations for such (desire to shield partner from distress, desire to shield self from distress). METHODS Eighty hematopoietic stem cell transplant patients and their spousal caregivers/ partners completed measures designed to assess protective buffering and relationship satisfaction at two time points: prior to the transplant (T1) and 50 days post-transplant (T2). Overall mental health was also assessed at T2. RESULTS There was moderate agreement between one dyad member’s reported buffering of his/ her partner, and the partner’s perception of the extent to which s/he felt buffered. Caregivers buffered patients more than patients buffered caregivers, especially at T2. The more participants buffered their partners at T2, and the more they felt buffered, the lower their concurrent relationship satisfaction and the poorer their mental health. The latter effect was particularly true for patients who buffered, and patients who felt buffered. With respect to motivations, patients who buffered primarily to protect their partner at T1 reported increases in relationship satisfaction over time, but when they did so at T2, their caregiver reported concurrent decreases in relationship satisfaction. CONCLUSIONS Protective buffering is costly, in that those who buffer and those who feel buffered report adverse psychosocial outcomes. In addition, buffering enacted by patients with an intention to help may prove counterproductive, ultimately hurting the object of such protection. PMID:19731352

  16. Gender differences in use of hearing protection devices among farm operators

    Directory of Open Access Journals (Sweden)

    Marjorie C McCullagh

    2016-01-01

    Full Text Available Purpose: Although farm operators have frequent exposure to hazardous noise and high rates of noise-induced hearing loss, they have low use of hearing protection devices (HPDs. Women represent about one-third of farm operators, and their numbers are climbing. However, among published studies examining use of HPDs in this worker group, none have examined gender-related differences. The purpose of this study was to examine gender-related differences in use of hearing protection and related predictors among farm operators. Materials and Methods: Data previously collected at farm shows and by telephone were analyzed using t-tests and generalized linear model with zero inflated negative binomial (ZINB distribution. Findings: The difference in rate of hearing protector use between men and women farm operators was not significant. There was no difference between men and women in most hearing protector-related attitudes and beliefs. Conclusion: Although men and women farm operators had similar rates of use of hearing protectors when working in high-noise environments, attitudes about HPD use differed. Specifically, interpersonal role modeling was a predictor of HPD use among women, but not for men. This difference suggests that while farm operators of both genders may benefit from interventions designed to reduce barriers to HPD use (e.g., difficulty communicating with co-workers and hearing warning sounds, farm women have unique needs in relation to cognitive-perceptual factors that predict HPD use. Women farm operators may lack role models for use of HPDs (e.g., in peers and advertising, contributing to their less frequent use of protection.

  17. Eye dosimetry and protective eye wear for interventional clinicians

    International Nuclear Information System (INIS)

    Martin, C.J.; Magee, J.S.; Sandblom; Almen, A.; Lundh, C.

    2015-01-01

    Doses to the eyes of interventional clinicians can exceed 20 mSv. Various protective devices can afford protection to the eyes with the final barrier being protective eye wear. The protection provided by lead glasses is difficult to quantify, and the majority of dosimeters are not designed to be worn under lead glasses. This study has measured dose reduction factors (DRFs) equal to the ratio of the dose with no protection, divided by that when lead glasses are worn. Glasses have been tested in X-ray fields using anthropomorphic phantoms to simulate the patient and clinician. DRFs for X-rays incident from the front vary from 5.2 to 7.6, while values for orientations reminiscent of clinical practice are between 1.4 and 5.2. Results suggest that a DRF of two is a conservative factor that could be applied to personal dosimeter measurements to account for the dose reduction provided by most types of lead glasses. (authors)

  18. Trends in monitoring pharmaceuticals and personal-care products in the aquatic environment by use of passive sampling devices

    Science.gov (United States)

    Mills, G.A.; Vrana, B.; Allan, I.; Alvarez, D.A.; Huckins, J.N.; Greenwood, R.

    2007-01-01

    The use of passive sampling in monitoring pharmaceuticals and personal-care products (PPCPs) in the aquatic environment is discussed. The utility of passive sampling methods for monitoring the fraction of heavy metals and the biologically available fraction of non-polar organic priority pollutants is recognized and these technologies are being used in surveys of water quality. These devices are used to measure the dissolved fraction and they can yield information that can be used in the development of risk assessments models. These devices can also be used to locate illegal dumping and to monitor specific sources of input of PPCPs into the environment, or to monitor the effectiveness of water treatment processes in the removal of these compounds from wastewater. These devices can provide representative information at low cost which necessitate a combination of laboratory calibration and field studies for emerging pollutants.

  19. Effects of low speed wind on the recognition/identification and pass-through communication tasks of auditory situation awareness afforded by military hearing protection/enhancement devices and tactical communication and protective systems.

    Science.gov (United States)

    Lee, Kichol; Casali, John G

    2016-01-01

    To investigate the effect of controlled low-speed wind-noise on the auditory situation awareness performance afforded by military hearing protection/enhancement devices (HPED) and tactical communication and protective systems (TCAPS). Recognition/identification and pass-through communications tasks were separately conducted under three wind conditions (0, 5, and 10 mph). Subjects wore two in-ear-type TCAPS, one earmuff-type TCAPS, a Combat Arms Earplug in its 'open' or pass-through setting, and an EB-15LE electronic earplug. Devices with electronic gain systems were tested under two gain settings: 'unity' and 'max'. Testing without any device (open ear) was conducted as a control. Ten subjects were recruited from the student population at Virginia Tech. Audiometric requirements were 25 dBHL or better at 500, 1000, 2000, 4000, and 8000 Hz in both ears. Performance on the interaction of communication task-by-device was significantly different only in 0 mph wind speed. The between-device performance differences varied with azimuthal speaker locations. It is evident from this study that stable (non-gusting) wind speeds up to 10 mph did not significantly degrade recognition/identification task performance and pass-through communication performance of the group of HPEDs and TCAPS tested. However, the various devices performed differently as the test sound signal speaker location was varied and it appears that physical as well as electronic features may have contributed to this directional result.

  20. Effectiveness of personal protective equipment: Relevance of dermal and inhalation exposure to chlorpyrifos among pest control operators

    NARCIS (Netherlands)

    Jagt, K. van der; Tielemans, E.; Links, I.; Brouwer, D.; Hemmen, J. van

    2004-01-01

    This study assessed the effectiveness of a custom fit personal protective equipment (PPE) program aimed at reducing occupational exposure to pesticides. The intervention study was carried out on 15 pest control operators (PCOs) during mixing/loading and application of chlorpyrifos. Each worker was

  1. Are organisations in South Africa ready to comply with personal data protection or privacy legislation and regulations?

    CSIR Research Space (South Africa)

    Baloyi, Ntsako

    2017-06-01

    Full Text Available people. Organisations require people’s trust and in turn, people are entitled to demand, as far as practicable and lawful, certain privileges from these organisations, such as the right to data protection or privacy. The power imbalance between... of restrictions on international data transfers, where there are no ‘adequate’ levels of personal data protection [5, 6]. This could have dire consequences for businesses. The European Union (EU) Directive [5] was a game changer. It resulted in the conclusion...

  2. Eye Pull, Eye Push: Moving Objects between Large Screens and Personal Devices with Gaze and Touch

    OpenAIRE

    Turner , Jayson; Alexander , Jason; Bulling , Andreas; Schmidt , Dominik; Gellersen , Hans

    2013-01-01

    Part 4: Gaze-Enabled Interaction Design; International audience; Previous work has validated the eyes and mobile input as a viable approach for pointing at, and selecting out of reach objects. This work presents Eye Pull, Eye Push, a novel interaction concept for content transfer between public and personal devices using gaze and touch. We present three techniques that enable this interaction: Eye Cut & Paste, Eye Drag & Drop, and Eye Summon & Cast. We outline and discuss several scenarios in...

  3. Commercial Smartphone-Based Devices and Smart Applications for Personalized Healthcare Monitoring and Management.

    Science.gov (United States)

    Vashist, Sandeep Kumar; Schneider, E Marion; Luong, John H T

    2014-08-18

    Smartphone-based devices and applications (SBDAs) with cost effectiveness and remote sensing are the most promising and effective means of delivering mobile healthcare (mHealthcare). Several SBDAs have been commercialized for the personalized monitoring and/or management of basic physiological parameters, such as blood pressure, weight, body analysis, pulse rate, electrocardiograph, blood glucose, blood glucose saturation, sleeping and physical activity. With advances in Bluetooth technology, software, cloud computing and remote sensing, SBDAs provide real-time on-site analysis and telemedicine opportunities in remote areas. This scenario is of utmost importance for developing countries, where the number of smartphone users is about 70% of 6.8 billion cell phone subscribers worldwide with limited access to basic healthcare service. The technology platform facilitates patient-doctor communication and the patients to effectively manage and keep track of their medical conditions. Besides tremendous healthcare cost savings, SBDAs are very critical for the monitoring and effective management of emerging epidemics and food contamination outbreaks. The next decade will witness pioneering advances and increasing applications of SBDAs in this exponentially growing field of mHealthcare. This article provides a critical review of commercial SBDAs that are being widely used for personalized healthcare monitoring and management.

  4. Sun protection practices among offspring of women with personal or family history of skin cancer.

    Science.gov (United States)

    Geller, Alan C; Brooks, Daniel R; Colditz, Graham A; Koh, Howard K; Frazier, A Lindsay

    2006-04-01

    Family history of skin cancer is an important determinant of skin cancer risk for offspring. No previous study of the effect of personal or family history of skin cancer on the sun protection behaviors of the offspring has been published. A retrospective study was conducted of the sun protection behaviors of the adolescent participants in the Growing Up Today Study (GUTS), who were offspring of mothers from the Nurses Health Study II. Adolescents' surveys were matched with their mothers' reports of a personal or family history of skin cancer and compared with adolescents whose mothers did not report a personal or family history of skin cancer. The outcome measures were (1) occurrence of frequent sunburns during the past summer, (2) use of a tanning bed during the past year, and (3) routine use of sunscreen. Frequent sunburns were defined as the report of > or = 3 sunburns during the past summer. We compared those who reported having used a tanning bed in the past year at least once with those who reported no tanning bed use in the past year. Routine use of sunscreen was defined as a respondent who replied that he or she "always" or "often" used sunscreen with sun protection factor of 15 or more when he or she was outside for > 15 minutes on a sunny day during the past summer. General estimating equations were used to calculate odds ratios and 95% confidence intervals adjusted for gender, age, color of untanned skin, and number of friends who were tanned. We also conducted an additional analysis restricted to children whose mothers had received a diagnosis of skin cancer in which we assessed sun protection behaviors according to the child's age and mother's age at the time of the mother's diagnosis and the number of years that had passed since the diagnosis of the mother's skin cancer. In 1999, 9943 children reported their sun protection behaviors; 8697 of their mothers had not received a diagnosis of skin cancer or reported a family history of melanoma, 463

  5. Collection, Use, Disclosure and Protection of Personal Information ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    whoskin

    addresses, personal and/or work email addresses, personal and/or work or cell telephone numbers); and. • language testing and language assessment results. How Do We Use Your Personal Information? We use the personal information you provide exclusively for the purposes of processing, screening, assessing ...

  6. Thin-film encapsulation of organic electronic devices based on vacuum evaporated lithium fluoride as protective buffer layer

    Science.gov (United States)

    Peng, Yingquan; Ding, Sihan; Wen, Zhanwei; Xu, Sunan; Lv, Wenli; Xu, Ziqiang; Yang, Yuhuan; Wang, Ying; Wei, Yi; Tang, Ying

    2017-03-01

    Encapsulation is indispensable for organic thin-film electronic devices to ensure reliable operation and long-term stability. For thin-film encapsulating organic electronic devices, insulating polymers and inorganic metal oxides thin films are widely used. However, spin-coating of insulating polymers directly on organic electronic devices may destroy or introduce unwanted impurities in the underlying organic active layers. And also, sputtering of inorganic metal oxides may damage the underlying organic semiconductors. Here, we demonstrated that by utilizing vacuum evaporated lithium fluoride (LiF) as protective buffer layer, spin-coated insulating polymer polyvinyl alcohol (PVA), and sputtered inorganic material Er2O3, can be successfully applied for thin film encapsulation of copper phthalocyanine (CuPc)-based organic diodes. By encapsulating with LiF/PVA/LiF trilayer and LiF/Er2O3 bilayer films, the device lifetime improvements of 10 and 15 times can be achieved. These methods should be applicable for thin-film encapsulation of all kinds of organic electronic devices. Moisture-induced hole trapping, and Al top electrode oxidation are suggest to be the origins of current decay for the LiF/PVA/LiF trilayer and LiF/Er2O3 bilayer films encapsulated devices, respectively.

  7. Home Use Devices: How to Prepare for and Handle Power Outages for Medical Devices That Require Electricity

    Science.gov (United States)

    ... to Create a Personal Emergency File My personal emergency file contains: □ Instructions for using the medical device and all device manuals. □ First aid kit □ Medical records □ Insurance cards □ Current home care doctor’s orders □ Plan of treatment □ What a family ...

  8. Mobile device security for dummies

    CERN Document Server

    Campagna, Rich; Krishnan, Ashwin

    2011-01-01

    The information you need to avoid security threats on corporate mobile devices Mobile devices have essentially replaced computers for corporate users who are on the go and there are millions of networks that have little to no security. This essential guide walks you through the steps for securing a network and building a bulletproof framework that will protect and support mobile devices in the enterprise. Featuring real-world case scenarios, this straightforward guide shares invaluable advice for protecting mobile devices from the loss of sensitive and confidential corporate informati

  9. Maintenance of influenza virus infectivity on the surfaces of personal protective equipment and clothing used in healthcare settings.

    Science.gov (United States)

    Sakaguchi, Hiroko; Wada, Koji; Kajioka, Jitsuo; Watanabe, Mayumi; Nakano, Ryuichi; Hirose, Tatsuko; Ohta, Hiroshi; Aizawa, Yoshiharu

    2010-11-01

    The maintenance of infectivity of influenza viruses on the surfaces of personal protective equipment and clothing is an important factor in terms of controlling viral cross-infection in the environment and preventing contact infection. The aim of this study was to determine if laboratory-grown influenza A (H1N1) virus maintained infectivity on the surfaces of personal protective equipment and clothing used in healthcare settings. Influenza A virus (0.5 mL) was deposited on the surface of a rubber glove, an N95 particulate respirator, a surgical mask made of non-woven fabric, a gown made of Dupont Tyvek, a coated wooden desk, and stainless steel. Each sample was left for 1, 8, and 24 h, and hemagglutination (HA) and 50% tissue culture infective dose (TCID(50))/mL were measured. The HA titer of this influenza A virus did not decrease in any of the materials tested even after 24 h. The infectivity of influenza A virus measured by TCID(50) was maintained for 8 h on the surface of all materials, with the exception of the rubber glove for which virus infectivity was maintained for 24 h. Our results indicate that the replacement/renewal of personal protective equipment and clothing by healthcare professionals in cases of exposure to secretions and droplets containing viruses spread by patients is an appropriate procedure to prevent cross-infection.

  10. Predicting sun protection behaviors using protection motivation variables.

    Science.gov (United States)

    Ch'ng, Joanne W M; Glendon, A Ian

    2014-04-01

    Protection motivation theory components were used to predict sun protection behaviors (SPBs) using four outcome measures: typical reported behaviors, previous reported behaviors, current sunscreen use as determined by interview, and current observed behaviors (clothing worn) to control for common method bias. Sampled from two SE Queensland public beaches during summer, 199 participants aged 18-29 years completed a questionnaire measuring perceived severity, perceived vulnerability, response efficacy, response costs, and protection motivation (PM). Personal perceived risk (similar to threat appraisal) and response likelihood (similar to coping appraisal) were derived from their respective PM components. Protection motivation predicted all four SPB criterion variables. Personal perceived risk and response likelihood predicted protection motivation. Protection motivation completely mediated the effect of response likelihood on all four criterion variables. Alternative models are considered. Strengths and limitations of the study are outlined and suggestions made for future research.

  11. Cerebral protection devices for use during carotid artery angioplasty with stenting: a health technology assessment.

    Science.gov (United States)

    Menon, Devidas; Stafinski, Tania

    2006-01-01

    This study sought to examine the safety, efficacy, and economic implications of the use of cerebral protection devices during carotid artery angioplasty and stenting (CAS) in high-risk patients with severe carotid artery disease (CAD). A comprehensive search for peer- and non-peer-reviewed studies that compared carotid endarterectomy (CEA) or CAS without cerebral protection to CAS with cerebral protection and appeared in the English language literature between January 1990 and January 2005 was completed. Information from studies identified was extracted using a common data abstraction form and then critically appraised against published quality assessment criteria. Of the eight studies found, six provided information on technical or procedural success rates, with values ranging from 95.6 percent to 100 percent. Three of the four studies comparing groups of patients who received CAS with cerebral protection with those who received only CAS reported a non-statistically significantly higher 30-day incidence of death and stroke (major or minor) in the latter group. None of the three studies comparing CAS with cerebral protection to CEA demonstrated a statistically significant difference in the 30-day incidence of death, major stroke, or myocardial infarction between treatment groups. No economic analyses were found. In high-risk patients with severe CAD, the evidence suggests that CAS with cerebral protection may offer a safe and efficacious alternative to CEA, reducing the risk of embolic peri-procedural complications associated with CAS to acceptable levels.

  12. 33 CFR 159.75 - Overcurrent protection.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Overcurrent protection. 159.75...) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159.75 Overcurrent protection. Overcurrent protection must be provided within the unit to protect subcomponents of the device if the...

  13. Qualifications of persons working in radiation user's organization and radiation protection training required for competence

    International Nuclear Information System (INIS)

    2004-04-01

    The Guide sets out the requirements governing the qualifications of persons working in userAes organizations and the radiation protection training required for such competence. It also sets out the requirements for training organizations arranging radiation safety officer training and exams. The Guide applies only to uses of radiation requiring a afety licence. The requirements for userAes organizations are set out in Guide ST 1.4

  14. Personal protective equipment and improving compliance among healthcare workers in high-risk settings.

    Science.gov (United States)

    Honda, Hitoshi; Iwata, Kentaro

    2016-08-01

    Personal protective equipment (PPE) protects healthcare workers (HCWs) from infection by highly virulent pathogens via exposure to body fluids and respiratory droplets. Given the recent outbreaks of contagious infectious diseases worldwide, including Ebola virus and Middle Eastern respiratory syndrome, there is urgent need for further research to determine optimal PPE use in high-risk settings. This review intends to provide a general understanding of PPE and to provide guidelines for appropriate use based on current evidence. Although previous studies have focused on the efficacy of PPE in preventing transmission of pathogens, recent studies have examined the dangers to HCWs during removal of PPE when risk of contamination is highest. Access to adequate PPE supplies is crucial to preventing transmission of pathogens, especially in resource-limited settings. Adherence to appropriate PPE use is a challenge due to inadequate education on its usage, technical difficulties, and tolerability of PPE in the workplace. Future projects aim at ameliorating this situation, including redesigning PPE which is crucial to improving the safety of HCWs. PPE remains the most important strategy for protecting HCW from potentially fatal pathogens. Further research into optimal PPE design and use to improve the safety of HCWs is urgently needed.

  15. Collection of regulatory texts related to radiation protection (collection of legal and regulatory measures related to radiation protection). Part 1: laws and decrees (Extracts of the Public Health Code and of the Labour Code dealing with the protection of population, patients and workers against the hazards of ionizing radiations); Part 2: orders, decisions, non codified decrees (Orders and decisions taken in application of the Public Health Code and of the Labour Code dealing with the protection of population, patients and workers against the hazards of ionizing radiations)

    International Nuclear Information System (INIS)

    Rivas, R.; Saad, N.; Niel, X.; Cottin, V.; Lachaume, J.L.; Feries, J.

    2011-01-01

    The first part contains legal and regulatory texts extracted from the Public Health Code and related to health general protection and to health products (medical devices), from the Social Security Code, and from the Labour Code related to individual work relationships, to health and safety at work, to work places, to work equipment and means of protection, to the prevention of some exposure risks and of risks related to some activities. The second part gathers texts extracted from the Public Health Code and related to ionizing radiations (general measures for the protection of the population, exposure to natural radiations, general regime of authorizations and declarations, purchase, retailing, importation, exportation, transfer and elimination of radioactive sources, protection of persons exposed to ionizing radiations for medical or forensics purposes, situations of radiological emergency and of sustained exposure to ionizing radiations, control), to the safety of waters and food products, and to the control of medical devices, to the protection of patients. It also contains extracts for the Labour Code related to workers protection

  16. Face Verification for Mobile Personal Devices

    NARCIS (Netherlands)

    Tao, Q.

    2009-01-01

    In this thesis, we presented a detailed study of the face verification problem on the mobile device, covering every component of the system. The study includes face detection, registration, normalization, and verification. Furthermore, the information fusion problem is studied to verify face

  17. Between the Profiles Pay Per View and the Protection of Personal Data: the Product is You

    Directory of Open Access Journals (Sweden)

    Ana Karin CHÁVEZ VALDIVIA

    2017-03-01

    Full Text Available Perhaps in the past was difficult to imagine that the moment in which someone could register each purchase that has been made, each book that has been read or each thing that has been said would come. That there would be companies storing data about our physical activity, behaviors, preferences and choices all the time. Most of the personal data comes from acts as daily as installing an application, completing a form, purchasing a product or requesting a service. This information provided sometimes consciously, voluntarily and with relative knowledge of the destination that will have, contrasts with situations in which data are inferred, deduced, extracted and manipulated.  In this sense, within a context in which the only access to the database has been left behind to give way to the creation of these by third parties, we wonder about the possible denaturation of the personal data and sensitive information that when get transformed in raw material through the analysis of existent connections and extraction of new data implicit in the multitude of information compiled in public or private databases, would convert  people into an essential product for the market; while the development of citizen profiles pay per view would allow predicting behaviors, selections and multiple deployments in different aspects of our lives. It is probable that in the defenselessness condition where we are now for having passed from personal space to social one and from there to the market many times without our knowledge and consent makes necessary to reconsider the current forms of protection and mechanisms of  legal protection around our personal data.

  18. Functional needs which led to the use of digital computing devices in the protection system of 1300 MW units

    International Nuclear Information System (INIS)

    Dalle, H.

    1986-01-01

    After a review of classical protection functions used in 900 MW power plants, it is concluded that in order to have functioning margins it is useful to calculate more finely the controled parameters. These calculating needs lead to the use of digital computing devices. Drawing profit from the new possibilities one can improve the general performances of the protection system with regard to availability, safety and maintenance. These options in the case of PALUEL led to the realization of SPIN, described here

  19. Radiation emitting devices act

    International Nuclear Information System (INIS)

    1970-01-01

    This Act, entitled the Radiation Emitting Devices Act, is concerned with the sale and importation of radiation emitting devices. Laws relating to the sale, lease or import, labelling, advertising, packaging, safety standards and inspection of these devices are listed as well as penalties for any person who is convicted of breaking these laws

  20. Research on Experiment of Islanding Protection Device of Grid-connected Photovoltaic System Based on RTDS

    Science.gov (United States)

    Zhou, Ning; Yang, Jia; Cheng, Zheng; Chen, Bo; Su, Yong Chun; Shu, Zhan; Zou, Jin

    2017-06-01

    Solar photovoltaic power generation is the power generation using solar cell module converting sunlight into DC electric energy. In the paper an equivalent model of solar photovoltaic power generation system is built in RTDS. The main circuit structure of the two-stage PV grid-connected system consists of the DC-DC, DC-AC circuit. The MPPT (Maximum Power Point Tracking) control of the PV array is controlled by adjusting the duty ratio of the DC-DC circuit. The proposed control strategy of constant voltage/constant reactive power (V/Q) control is successfully implemented grid-connected control of the inverter when grid-connected operation. The closed-loop experiment of islanding protection device of photovoltaic power plant on RTDS, verifies the correctness of the simulation model, and the experimental verification can be applied to this type of device.

  1. Reactor protection device

    Energy Technology Data Exchange (ETDEWEB)

    Shida, T; Hirose, M

    1977-01-19

    Purpose: To prevent abrupt increase or decrease in the recycling flow rate by comparing output signals from controllers in each of the loops in the recycling flow rate control system to lock the positions of fluid coupling scooping pipes or flow control valves corresponding to the groups generating abnormal signals. Constitution: The recycling flow rate is controlled by the r.p.m. of a motor directly coupled with a recycling pump and the value of r.p.m. is in proportion to the generator frequency varied with the sliding operation of the fluid coupling in MG set. The sliding operation of the fluid coupling is adjusted by a scooping pipe driver. When the device is set to automatic operation, the output signal of the main controller is delivered to the recycling flow rate control system, the output signal of which is input to respective scooping pipe drivers. The loop output signals are supplied to an adder where the deviation signal between both of them are detected and the scooping pipe is locked if the set value is exceeded.

  2. Reactor protection device

    International Nuclear Information System (INIS)

    Shida, Toichi; Hirose, Masao.

    1977-01-01

    Purpose: To prevent abrupt increase or decrease in the recycling flow rate by comparing output signals from controllers in each of the loops in the recycling flow rate control system to thereby lock the positions of fluid coupling scooping pipes or flow control valves corresponding to the groups generating abnormal signals. Constitution: The recycling flow rate is controlled by r.p.m. of a motor directly coupled with a recycling pump and the value of r.p.m. is in proportion to the generator frequency varied with the sliding operation of the fluid coupling in MG set. The sliding operation of the fluid coupling is adjusted by a scooping pipe driver. When the device is set to automatic operation, the output signal of the main controller is delivered to the recycling flow rate control system, the output signal of which is input to respective scooping pipe drivers. The loop output signals are supplied to an adder where the deviation signal between both of them are detected and the scooping pipe is locked if the set value is exceeded. (Yoshino, M.)

  3. Protection for a thermonuclear device

    International Nuclear Information System (INIS)

    Shimada, Ryuichi; Sasatani, Shin-ichi.

    1983-01-01

    Purpose: To suppress an abnormal voltage due to potential changes by a characteristic impedance composed of a discharge gap, a resistance and a capacitor, as well as absorb the energy of the abnormal voltage by properly selecting the current capacity of the resistor. Constitution: An abnormal voltage generated in a current transformer coils is detected by an abnormal voltage detector and an output signal therefrom causes a high voltage generating device to generate a high voltage, whereby electric discharge is taken place across a discharge gap to absorb the energy of the abnormal voltage in a resistor and a capacitor. For the abnormal voltage from the plasmas, the voltage across the transformer coils can be suppressed to some extent by selecting the impedance for the current transformer coils and the impedance for the parallel circuit of the resistor and the capacitor to an appropriate ratio. While on the other hand, after throwing a switcher by the actuation of a switcher control device, the energy for the abnormal voltage can sufficiently be absorbed through the internal resistance of the transformer coils and the resistance for the entire current. (Yoshino, Y.)

  4. Radiation protection

    International Nuclear Information System (INIS)

    1989-01-01

    A NRPB leaflet in the 'At-a-Glance' series explains in a simple but scientifically accurate way what radiation is, the biological effects and the relative sensitivity of different parts of the human body. The leaflet then discusses radiation protection principles, radiation protection in the UK and finally the effectiveness of this radiation protection as judged by a breakdown of the total dose received by an average person in the UK, a heavy consumer of Cumbrian seafood, an average nuclear industry worker and an average person in Cornwall. (UK)

  5. Influence of stent design and use of protection devices on outcome of carotid artery stenting: a pooled analysis of individual patient data.

    Science.gov (United States)

    Wodarg, Fritz; Turner, Elisabeth L; Dobson, Joanna; Ringleb, Peter A; Mali, Willem P; Fraedrich, Gustav; Chatellier, Gilles; Bequemin, Jean-Pierre; Brown, Martin M; Algra, Ale; Mas, Jean-Louis; Jansen, Olav; Bonati, Leo H

    2018-04-19

    Carotid artery stenting is an alternative to endarterectomy for the treatment of symptomatic carotid stenosis but was associated with a higher risk of procedural stroke or death in randomized controlled trials (RCTs). Technical aspects of treatment may partly explain these results. The purpose of this analysis was to investigate the influence of technical aspects such as stent design or the use of protection devices, as well as clinical variables, on procedural risk. We pooled data of 1557 individual patients receiving stent treatment in three large RCTs comparing stenting versus endarterectomy for symptomatic carotid stenosis. The primary outcome event was any procedural stroke or death occurring within 30 days after stenting. Procedural stroke or death occurred significantly more often with the use of open-cell stents (61/595 patients, 10.3%) than with closed-cell stents (58/962 patients, 6.0%; RR 1.76; 95% CI 1.23 to 2.52; P=0.002). Procedural stroke or death occurred in 76/950 patients (8.0%) treated with protection devices (predominantly distal filters) and in 43/607 (7.1%) treated without protection devices (RR 1.10; 95% CI 0.71 to 1.70; P=0.67). Clinical variables predicting the primary outcome event were age, severity of the qualifying event, history of prior stroke, and level of disability at baseline. The effect of stent design remained similar after adjustment for these variables. In symptomatic carotid stenosis, the use of stents with a closed-cell design is independently associated with a lower risk of procedural stroke or death compared with open-cell stents. Filter-type protection devices do not appear to reduce procedural risk. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. Impact of Different Personal Protective Clothing on Wildland Firefighters' Physiological Strain.

    Science.gov (United States)

    Carballo-Leyenda, Belén; Villa, José G; López-Satué, Jorge; Rodríguez-Marroyo, Jose A

    2017-01-01

    Wildfire firefighting is an extremely demanding occupation performed under hot environment. The use of personal protective clothing (PPC) is needed to protect subjects from the thermal exposure. However, the additional use of PPC may increase the wildland firefighters' physiological strain, and consequently limit their performance. The aim of this study was to analyze the effect of four different PPC on the physiological strain of wildland firefighters under moderate conditions (30°C and 30% RH). Eight active and healthy wildland firefighters performed a submaximal walking test wearing a traditional short sports gear and 4 different PPC. The materials combination (viscose, Nomex, Kevlar, P-140 and fire resistant cotton) used during the PPC manufacturing process was different. During all tests, to simulate a real scenario subjects wore a backpack pump (20 kg). Heart rate, respiratory gas exchange, gastrointestinal temperature, blood lactate concentration, perceived exertion and temperature and humidity underneath the PPC were recorded throughout tests. Additionally, parameters of heat balance were estimated. Wearing a PPC did not cause a significant increase in the subjects' physiological response. The gastrointestinal temperature increment, the relative humidity of the microclimate underneath the PPC, the sweat residue in PPC, the sweat efficiency, the dry heat exchange and the total clothing insulation were significantly affected according to the PPC fabric composition. These results suggest that the PPC composition affect the moisture management. This might be taken into account to increase the wildland firefighters' protection in real situations, when they have to work close to the flames.

  7. Impact of Different Personal Protective Clothing on Wildland Firefighters' Physiological Strain

    Directory of Open Access Journals (Sweden)

    Belén Carballo-Leyenda

    2017-08-01

    Full Text Available Wildfire firefighting is an extremely demanding occupation performed under hot environment. The use of personal protective clothing (PPC is needed to protect subjects from the thermal exposure. However, the additional use of PPC may increase the wildland firefighters' physiological strain, and consequently limit their performance. The aim of this study was to analyze the effect of four different PPC on the physiological strain of wildland firefighters under moderate conditions (30°C and 30% RH. Eight active and healthy wildland firefighters performed a submaximal walking test wearing a traditional short sports gear and 4 different PPC. The materials combination (viscose, Nomex, Kevlar, P-140 and fire resistant cotton used during the PPC manufacturing process was different. During all tests, to simulate a real scenario subjects wore a backpack pump (20 kg. Heart rate, respiratory gas exchange, gastrointestinal temperature, blood lactate concentration, perceived exertion and temperature and humidity underneath the PPC were recorded throughout tests. Additionally, parameters of heat balance were estimated. Wearing a PPC did not cause a significant increase in the subjects' physiological response. The gastrointestinal temperature increment, the relative humidity of the microclimate underneath the PPC, the sweat residue in PPC, the sweat efficiency, the dry heat exchange and the total clothing insulation were significantly affected according to the PPC fabric composition. These results suggest that the PPC composition affect the moisture management. This might be taken into account to increase the wildland firefighters' protection in real situations, when they have to work close to the flames.

  8. Collection of regulatory texts relative to radiation protection. Part 2: by-laws, decisions, non-codified decrees / Collection of legal and statutory provisions relative to radiation protection. Part 2: by-laws and decisions taken in application of the Public Health Code and Labour Code concerning the protection of populations, patients and workers against the risks of ionizing radiations

    International Nuclear Information System (INIS)

    Rivas, Robert; Feries, Jean; Marzorati, Frank; Chevalier, Celine; Lachaume, Jean-Luc

    2012-01-01

    This second part gathers texts extracted from the Public Health Code and related to ionizing radiations (general measures for the protection of the population, exposure to natural radiations, general regime of authorizations and declarations, purchase, retailing, importation, exportation, transfer and elimination of radioactive sources, protection of persons exposed to ionizing radiations for medical or forensics purposes, situations of radiological emergency and of sustained exposure to ionizing radiations, control), to the safety of waters and food products, and to the control of medical devices, to the protection of patients. It also contains extracts for the Labour Code related to workers protection. This document is an update of the previous version from March 2011

  9. Code of Practice for the Protection of Persons against Ionizing Radiations arising from Medical and Dental Use

    Energy Technology Data Exchange (ETDEWEB)

    1972-01-01

    This Code is a revision of the 1964 Code of Practice for the protection of persons against ionizing radiations arising from medical and dental use. This revised Code (which does not have the force of law) applies to the use of ionizing radiations arising from all forms of medical and dental practice and from allied research involving human subjects. It covers both workers, patients and members of the public. Although the arrangements recommended relate primarily to institutions they should be applied, as far as possible, by all medical and dental practitioners. The Code has been drawn up in the light of the recommendations of the International Commission on Radiological Protection (ICRP) and of the views of the Medical Research Council's Committee on Protection against Ionizing Radiations.

  10. Report of the work-group derived from the permanent radioprotection expert Group on the desirable evolutions for the functions and training of persons with expertise in radiation protection

    International Nuclear Information System (INIS)

    2010-01-01

    This report first discusses the issues of training in radiation protection within the French national context by distinguishing training in relationship with workers' radiation protection (internal training in radiation protection as foreseen in the French Work Code, training in the industrial field, training in the field of radioactive material transportation, training of the person with expertise in radiation protection or PCR), and training in relationship with patient radiation protection (training of the person specialised in medical radio-physics, training in patient radiation protection). It describes the situation and evolution perspectives at the European level by addressing the situation in different countries (Great-Britain, Belgium, Switzerland), the content of the 96/29/Euratom directive, the current evolutions in Europe (European platform EUTERP, European programs ENETRAP, transposition of the 2006-123-CE directive, the 2005-36-CE directive and its revision), and some international aspects. The authors discuss strengths and weaknesses of the person with expertise in radiation protection (PCR), and state reflections and recommendations regarding the evolution of the present PCR arrangement

  11. Marco Civil da Internet: Limits From the Express and Unequivocal Requirement Consent as a Legal Protection of Personal Data on the Internet

    Directory of Open Access Journals (Sweden)

    Marco Antonio Lima

    2016-10-01

    Full Text Available This article examines the limits of the legal determination of express and unequivocal consent for the collection, use, storage, processing and protection of personal data as provided for in the Marco Civil da Internet (Law 12.965/2014 provided for in the list of rights and guarantees of users of the World Wide Web. With the increasing use of personal data from the Internet, for purposes of market analysis, prospecting investment trends, consumption and guidance of advertising campaigns - possible through technological resources for treatment and analysis of information - it is urgent to effectiveness the legal protection of this intangible property.

  12. Fungicide application practices and personal protective equipment use among orchard farmers in the agricultural health study.

    Science.gov (United States)

    Hines, C J; Deddens, J A; Coble, J; Alavanja, M C R

    2007-04-01

    Fungicides are routinely applied to deciduous tree fruits for disease management. Seventy-four private orchard applicators enrolled in the Agricultural Health Study participated in the Orchard Fungicide Exposure Study in 2002-2003. During 144 days of observation, information was obtained on chemicals applied and applicator mixing, application, personal protective, and hygiene practices. At least half of the applicators had orchards with orchard applicators.

  13. Commercial Smartphone-Based Devices and Smart Applications for Personalized Healthcare Monitoring and Management

    Directory of Open Access Journals (Sweden)

    Sandeep Kumar Vashist

    2014-08-01

    Full Text Available Smartphone-based devices and applications (SBDAs with cost effectiveness and remote sensing are the most promising and effective means of delivering mobile healthcare (mHealthcare. Several SBDAs have been commercialized for the personalized monitoring and/or management of basic physiological parameters, such as blood pressure, weight, body analysis, pulse rate, electrocardiograph, blood glucose, blood glucose saturation, sleeping and physical activity. With advances in Bluetooth technology, software, cloud computing and remote sensing, SBDAs provide real-time on-site analysis and telemedicine opportunities in remote areas. This scenario is of utmost importance for developing countries, where the number of smartphone users is about 70% of 6.8 billion cell phone subscribers worldwide with limited access to basic healthcare service. The technology platform facilitates patient-doctor communication and the patients to effectively manage and keep track of their medical conditions. Besides tremendous healthcare cost savings, SBDAs are very critical for the monitoring and effective management of emerging epidemics and food contamination outbreaks. The next decade will witness pioneering advances and increasing applications of SBDAs in this exponentially growing field of mHealthcare. This article provides a critical review of commercial SBDAs that are being widely used for personalized healthcare monitoring and management.

  14. Personal protective clothing against accidental immersion

    Energy Technology Data Exchange (ETDEWEB)

    Elliott, David; Tipton, Michael [Surrey Univ., Robens Inst. of Health and Safety, Guildford (United Kingdom)

    1997-12-31

    The requirements for protective clothing against accidental immersion are discussed and the advantages and limitations of the main types of immersion protection available are analysed. The variety of designs available reflects the various circumstances under which they may be used. In broad terms in the offshore industry these include the following activities: normal work without risk of immersion but with a possible need to abandon the rig or ship; work in areas where there is risk of accidentally falling into the sea; flying over the sea in a helicopter. The first response to sudden immersion in sea water, which must usually be considered to be cold, is a sudden gasp often followed by an immediate phase of uncontrolled breathing. Since control of ones breathing between and under the breaking waves is essential to staying alive, this is a critical time. After surviving this initial ``cold shock`` phase, the effects of body heat loss become hazardous. Protection against hypothermia has been the priority for those providing survival suits and protective clothing while the hazard of the immediate response to cold immersion has been unrecognised to a large extent. (UK)

  15. Interactive lectures: Clickers or personal devices? [v1; ref status: indexed, http://f1000r.es/54w

    OpenAIRE

    Lesley J. Morrell; Domino A. Joyce

    2015-01-01

    Audience response systems (?clickers?) are frequently used to promote participation in large lecture classes, and evidence suggests that they convey a number of benefits to students, including improved academic performance and student satisfaction. The limitations of these systems (such as limited access and cost) can be overcome using students? personal electronic devices, such as mobile phones, tablets and laptops together with text message, web- or app-based polling systems. Using question...

  16. Attenuation of blast pressure behind ballistic protective vests.

    Science.gov (United States)

    Wood, Garrett W; Panzer, Matthew B; Shridharani, Jay K; Matthews, Kyle A; Capehart, Bruce P; Myers, Barry S; Bass, Cameron R

    2013-02-01

    Clinical studies increasingly report brain injury and not pulmonary injury following blast exposures, despite the increased frequency of exposure to explosive devices. The goal of this study was to determine the effect of personal body armour use on the potential for primary blast injury and to determine the risk of brain and pulmonary injury following a blast and its impact on the clinical care of patients with a history of blast exposure. A shock tube was used to generate blast overpressures on soft ballistic protective vests (NIJ Level-2) and hard protective vests (NIJ Level-4) while overpressure was recorded behind the vest. Both types of vest were found to significantly decrease pulmonary injury risk following a blast for a wide range of conditions. At the highest tested blast overpressure, the soft vest decreased the behind armour overpressure by a factor of 14.2, and the hard vest decreased behind armour overpressure by a factor of 56.8. Addition of body armour increased the 50th percentile pulmonary death tolerance of both vests to higher levels than the 50th percentile for brain injury. These results suggest that ballistic protective body armour vests, especially hard body armour plates, provide substantial chest protection in primary blasts and explain the increased frequency of head injuries, without the presence of pulmonary injuries, in protected subjects reporting a history of blast exposure. These results suggest increased clinical suspicion for mild to severe brain injury is warranted in persons wearing body armour exposed to a blast with or without pulmonary injury.

  17. The extent of using mobility assistive devices can partly explain fatigue among persons with late effects of polio - a retrospective registry study in Sweden.

    Science.gov (United States)

    Santos Tavares Silva, I; Sunnerhagen, K S; Willén, C; Ottenvall Hammar, I

    2016-11-18

    Fatigue is reported as one of the most disabling symptoms and is common among persons living with late effects of polio. Although fatigue has been studied in the context of people living with late effects of polio, there is a lack of knowledge concerning the association of fatigue and variables of importance for participation in daily life. Therefore, the aim of this study was to explore possible factors associated with fatigue among persons with late effects of polio in Sweden. This retrospective registry study consisted of 89 persons with late effects of polio living in Sweden. Fatigue was measured with the Multidimensional Fatigue Inventory (MFI-20) scale, Swedish version. Pearson's correlation coefficient was used to analyse the correlation between the factors and fatigue, and a multiple linear regression was carried out to explore factors for fatigue. Fatigue statistically significantly correlated with age (r = 0.234, p polio, and the model partly explained 14% of the variation of fatigue. Fatigue could partly be explained by the extent of using mobility assistive devices and age. Healthcare professionals should provide and demonstrate the importance of assistive devices to ensure management of fatigue in persons living with late effects of polio.

  18. Personal Protective Equipment Supply Chain: Lessons Learned from Recent Public Health Emergency Responses.

    Science.gov (United States)

    Patel, Anita; D'Alessandro, Maryann M; Ireland, Karen J; Burel, W Greg; Wencil, Elaine B; Rasmussen, Sonja A

    Personal protective equipment (PPE) that protects healthcare workers from infection is a critical component of infection control strategies in healthcare settings. During a public health emergency response, protecting healthcare workers from infectious disease is essential, given that they provide clinical care to those who fall ill, have a high risk of exposure, and need to be assured of occupational safety. Like most goods in the United States, the PPE market supply is based on demand. The US PPE supply chain has minimal ability to rapidly surge production, resulting in challenges to meeting large unexpected increases in demand that might occur during a public health emergency. Additionally, a significant proportion of the supply chain is produced off-shore and might not be available to the US market during an emergency because of export restrictions or nationalization of manufacturing facilities. Efforts to increase supplies during previous public health emergencies have been challenging. During the 2009 H1N1 influenza pandemic and the 2014 Ebola virus epidemic, the commercial supply chain of pharmaceutical and healthcare products quickly became critical response components. This article reviews lessons learned from these responses from a PPE supply chain and systems perspective and examines ways to improve PPE readiness for future responses.

  19. NCTA v. FCC - Do Commercial Free Speech Justifications Trump Consumers' Personal Data Protection Rights? Answer To Shape Mobile Advertising Industry

    DEFF Research Database (Denmark)

    Cleff, Evelyne Beatrix; King, Nancy J.

    2010-01-01

    's right to communicate with their customers. Considering privacy risks associated with advances in computer technology, the complexities of modern information processing and evolving mobile advertising (m-advertising) practices, privacy regulations should not be equated with unwarranted speech regulations...... balance between protecting consumers' information privacy in an era of pervasive data processing and protecting the rights of marketers to engage in protected commercial free speech that involves using customers' personal information. A ruling against the FCC would have limited the use of government...... to support the growth of the global mobile advertising (m-advertising) industry....

  20. Personal, Familial, and Social Risk and Protective Factors of Tendency towards Substance Use among Students

    Directory of Open Access Journals (Sweden)

    Morteza Jahanshahloo

    2016-07-01

    Full Text Available Background and Objective: University students are among vulnerable groups to tendency towards substance use. Accordingly, this study aimed to investigate the role of personal, familial, and social risk and protective factors in the prediction of tendency to this behavior among students.Materials and Methods: This descriptive correlational study was carried out on 431 students of Shahid Beheshti University of Medical Sciences who were selected by convenience sampling. Data were collected by Risk and Protective Factors Inventory (RPFI and Youth Risk Taking Scale (YRTS and then, were analyzed by Pearson correlation method and stepwise multivariate regression.Results: Data analysis using Pearson Correlation Coefficient showed significant relationships between personal (e.g. attitude towards substance use and tendency to drug use; r=0.6, P<0.01, familial (e.g. parent attitude towards substance and tendency towards smoking cigarettes; r=0.2, P<0.05, and social (e.g. perceived accessibility and tendency towards alcohol; r=0.4, P<0.01 factors with tendency to substance use. Moreover, the results of stepwise multivariate regression analysis indicated that personal factors (i.e. attitude towards substance use, sensation seeking, and impulsivity, social factors (i.e. friends’ substance use and perceived accessibility, and familial factors (i.e. family monitoring and parents’ attitude towards substance use were the best predictors of tendency towards substance use in students, respectively.Conclusion: In conclusion, current results indicated that a series of individual, familial, and social factors affect tendency towards substance use among students. Accordingly, identifying vulnerable students using suitable screening tests and providing them with primary prevention programs is of the utmost importance.

  1. The journey from texting to applications on personally owned devices to enhance student eEngagement in large lectures: A pilot study

    Directory of Open Access Journals (Sweden)

    Trevor Nesbit

    Full Text Available Increasing class sizes to gain economies of scale have resulted in less interaction between lecturers and students during lectures. This paper presented the results of a pilot study that set out to examine the use of applications on personally owned devices (APODs to enhance student interaction, participation and engagement in large lectures. The pilot study commences with the development and trial of a text messaging based application, and after a survey of students regarding ownership levels of mobile devices, concludes with the trial of an application developed for mobile devices. The conclusions of the paper highlight that the use of APODs can significantly increase student interaction, participation and engagement in large lectures and identifies implications and opportunities for further research.

  2. About Personal Protective Equipment (PPE)

    Science.gov (United States)

    ... some types of elastomeric respirator masks and protective eyewear such as goggles may be reused if the ... State & Local Officials Consumers Health Professionals Science & Research Industry Scroll back to top Popular Content Home Latest ...

  3. Interactive lectures: Clickers or personal devices? [v1; ref status: indexed, http://f1000r.es/54w

    Directory of Open Access Journals (Sweden)

    Lesley J. Morrell

    2015-03-01

    Full Text Available Audience response systems (‘clickers’ are frequently used to promote participation in large lecture classes, and evidence suggests that they convey a number of benefits to students, including improved academic performance and student satisfaction. The limitations of these systems (such as limited access and cost can be overcome using students’ personal electronic devices, such as mobile phones, tablets and laptops together with text message, web- or app-based polling systems. Using questionnaires, we compare student perceptions of clicker and smartphone based polling systems. We find that students prefer interactive lectures generally, but those that used their own device preferred those lectures over lectures using clickers. However, device users were more likely to report using their devices for other purposes (checking email, social media etc. when they were available to answer polling questions. These students did not feel that this distracted them from the lecture, instead, concerns over the use of smartphones centred around increased battery usage and inclusivity for students without access to suitable technology. Our results suggest that students generally preferred to use their own devices over clickers, and that this may be a sensible way to overcome some of the limitations associated with clickers, although issues surrounding levels of distraction and the implications for retention and recall of information need further investigation.

  4. Code of Practice for the Protection of Persons against Ionizing Radiations arising from Medical and Dental Use

    International Nuclear Information System (INIS)

    1972-01-01

    This Code is a revision of the 1964 Code of Practice for the protection of persons against ionizing radiations arising from medical and dental use. This revised Code (which does not have the force of law) applies to the use of ionizing radiations arising from all forms of medical and dental practice and from allied research involving human subjects. It covers both workers, patients and members of the public. Although the arrangements recommended relate primarily to institutions they should be applied, as far as possible, by all medical and dental practitioners. The Code has been drawn up in the light of the recommendations of the International Commission on Radiological Protection (ICRP) and of the views of the Medical Research Council's Committee on Protection against Ionizing Radiations. (NEA) [fr

  5. A performance study of radio-opaque personal protective fabrics for the reduction of transmittance of gamma-rays and neutrons

    International Nuclear Information System (INIS)

    Corcoran, E.C.; William Forest; Robert Horton; Kelly, D.G.; Kristine Mattson; Curtis McDonald; Nielsen, K.S.; Kristin Topping; Weir, R.D.; Andre Yonkeu

    2012-01-01

    Commercial radio-opaque combat (CRC) fabrics, for incorporation into personal protective equipment used by first responders and armed forces, are marketed as having the ability to provide a level of protection against specific types of radiation. For a CRC material, a standard combat uniform and a multi-layered chemical, biological, radiological, nuclear (CBRN) protective material, the present work examines chemical composition and radiation protection against gamma-rays and neutron fluxes. Significant reduction in gamma-ray transmittance occurs only for the CRC fabric (46-514 keV) with gamma-ray attenuation coefficients of 3.10 to 2 g -1 . Reduction in neutron transmittance, for all three fabrics, could not be assessed with certainty as the measured transmittance was obscured by large statistical uncertainties. (author)

  6. Can Smartphones and Privacy Coexist Assessing Technologies and Regulations Protecting Personal Data on Android and iOS Devices

    Science.gov (United States)

    2016-01-01

    from unknown sources even if they have not been approved for the app store (“Google Report: Android Security 2014 Year in Review,” 2014). This makes...Report: Android Security 2014 Year in Review,” 2014. As of October 2015: https://static.googleusercontent.com/media/source.android.com/ en//devices...Experience Returns for Security (BADGERS), September 11, 2014. Lockheimer, Hiroshi, “ Android and Security ,” Google Mobile Blog, February 2, 2012. As

  7. Microprocessor protection relays: new prospects or new problems?

    OpenAIRE

    Gurevich, Vladimir

    2006-01-01

    The internal architecture and principles of operation of microprocessor-based devices including so-called "microprocessor protective relays" have little in common with devices called "electric relays". But microprocessor-based relay protection devices are gradually driving out the traditional electromechanical and even electronic relay protection of virtually from all fields of power and electrical engineering. Advantages of microprocessor-based protection means over traditional ones are far ...

  8. Personal Protection of Permethrin-Treated Clothing against Aedes aegypti, the Vector of Dengue and Zika Virus, in the Laboratory.

    Science.gov (United States)

    Orsborne, James; DeRaedt Banks, Sarah; Hendy, Adam; Gezan, Salvador A; Kaur, Harparkash; Wilder-Smith, Annelies; Lindsay, Steve W; Logan, James G

    2016-01-01

    The dengue and Zika viruses are primarily transmitted by Aedes aegypti mosquitoes, which are most active during day light hours and feed both in and outside of the household. Personal protection technologies such as insecticide-treated clothing could provide individual protection. Here we assessed the efficacy of permethrin-treated clothing on personal protection in the laboratory. The effect of washing on treated clothing, skin coverage and protection against resistant and susceptible Ae. aegypti was assessed using modified WHO arm-in-cage assays. Coverage was further assessed using free-flight room tests to investigate the protective efficacy of unwashed factory-dipped permethrin-treated clothing. Clothing was worn as full coverage (long sleeves and trousers) and partial coverage (short sleeves and shorts). Residual permethrin on the skin and its effect on mosquitoes was measured using modified WHO cone assays and quantified using high-pressure liquid chromatography (HPLC) analysis. In the arm-in-cage assays, unwashed clothing reduced landing by 58.9% (95% CI 49.2-66.9) and biting by 28.5% (95% CI 22.5-34.0), but reduced to 18.5% (95% CI 14.7-22.3) and 11.1% (95% CI 8.5-13.8) respectively after 10 washes. Landing and biting for resistant and susceptible strains was not significantly different (ptreated clothing reduced landing by 24.3% (95% CI 17.4-31.7) and biting by 91% (95% CI 82.2-95.9) with partial coverage reducing landing and biting by 26.4% (95% CI 20.3-31.2) and 49.3% (95% CI 42.1-59.1) respectively with coverage type having no significant difference on landing (p80% one hour after wearing treated clothing. Whilst partially covering the body with permethrin-treated clothing provided some protection against biting, wearing treated clothing with long sleeves and trousers provided the highest form of protection. Washing treated clothing dramatically reduced protection provided. Permethrin-treated clothing could provide protection to individuals from Ae

  9. Multiobjective optimal placement of switches and protective devices in electric power distribution systems using ant colony optimization

    Energy Technology Data Exchange (ETDEWEB)

    Tippachon, Wiwat; Rerkpreedapong, Dulpichet [Department of Electrical Engineering, Kasetsart University, 50 Phaholyothin Rd., Ladyao, Jatujak, Bangkok 10900 (Thailand)

    2009-07-15

    This paper presents a multiobjective optimization methodology to optimally place switches and protective devices in electric power distribution networks. Identifying the type and location of them is a combinatorial optimization problem described by a nonlinear and nondifferential function. The multiobjective ant colony optimization (MACO) has been applied to this problem to minimize the total cost while simultaneously minimize two distribution network reliability indices including system average interruption frequency index (SAIFI) and system interruption duration index (SAIDI). Actual distribution feeders are used in the tests, and test results have shown that the algorithm can determine the set of optimal nondominated solutions. It allows the utility to obtain the optimal type and location of devices to achieve the best system reliability with the lowest cost. (author)

  10. Determinants of personal protective equipment (PPE) use in UK motorcyclists: exploratory research applying an extended theory of planned behaviour.

    Science.gov (United States)

    Norris, Emma; Myers, Lynn

    2013-11-01

    Despite evident protective value of motorcycle personal protective equipment (PPE), no research has assessed considerations behind its uptake in UK riders. A cross-sectional online questionnaire design was employed, with riders (n=268) recruited from online motorcycle forums. Principal component analysis found four PPE behavioural outcomes. Theoretical factors of intentions, attitudes, injunctive and descriptive subjective norms, risk perceptions, anticipated regret, benefits and habit were also identified for further analysis. High motorcycle jacket, trousers and boots wear, middling high-visibility wear and low non-Personal Protective Equipment wear were found. Greater intentions, anticipated regret and perceived benefits were significantly associated with increased motorcycle jacket, trousers and boots wear, with habit presence and scooter use significantly associated with increased high-visibility wear. Lower intentions, anticipated regret and risk perceptions, being female, not holding a car licence and urban riding were significantly associated with increased non-PPE wear. A need for freedom of choice and mixed attitudes towards PPE use were evident in additional comments. PPE determinants in this sample provide a preliminary basis for future uptake interventions. Larger scale and qualitative research is needed to further investigate relevant constructs. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Techniques in cerebral protection.

    Science.gov (United States)

    Fanelli, Fabrizio; Bezzi, Mario; Boatta, Emanuele; Passariello, Roberto

    2006-10-01

    Carotid angioplasty and stenting is a valid alternative option to conventional carotid endarterectomy in the treatment of carotid artery stenosis. During the stenting process, however, distal embolization can occur with neurological consequences. To avoid this, cerebral protection devices have been introduced. Three principal types of protection system have been developed: distal balloon occlusion, distal filters and proximal protection with or without reversal of flow. As protection devices became the focus of interest by manufactures and physicians, several trials are going on worldwide to analyze the characteristics of each of them and to evaluate their efficacy to reduce the rate of distal embolization.

  12. Lightning-Effects to the electronic devices and its support systems

    International Nuclear Information System (INIS)

    Mohd Said Yusof; Mohd Hanafiah Chik; Mohd Nor Hasli Mat Jusoh

    2011-01-01

    In Malaysia, lightning can happen mostly during the inter-change season. Lightning can happen in hill area including Nuclear Malaysia because its coordinate. Effects from these situation, many devices were damaged and it can bring the big losses to the Nuclear Malaysia where it can costed in replacing or repairing them. To avoid from happen, the placing of lightning protective system must be do in good manner and effectively. Besides that, knowledge about the system can be an advantage in order for those person in-charge to repairing or avoiding the same cases from re-happen in future. (author)

  13. Cerebral ischemia after filter-protected carotid artery stenting is common and cannot be predicted by the presence of substantial amount of debris captured by the filter device.

    Science.gov (United States)

    Maleux, G; Demaerel, P; Verbeken, E; Daenens, K; Heye, S; Van Sonhoven, F; Nevelsteen, A; Wilms, G

    2006-10-01

    Protected carotid artery stent placement is currently under clinical evaluation as a potential alternative to carotid endarterectomy. The current study was undertaken to determine the incidence of new ischemic lesions found on diffusion-weighted MR imaging (DWI) in nonselected patients after protected carotid artery stent placement using a filter device and to determine the potential relationship between these new ischemic lesions and the presence or absence of a clear amount of debris captured by the neuroprotection filter device. A nonrandomized cohort of 52 patients (40 men, 12 women) presenting with carotid occlusive disease underwent protected carotid artery stent placement using a filter device. DWI obtained 1 day before stent placement was compared with that obtained 1 day after stent placement. In addition, the macroscopic and microscopic analysis of debris captured by the filter device during the carotid stent placement procedure was assessed. Neuroprotected carotid stent placement was technically successful in all 53 procedures but was complicated by a transient ischemic attack in 3 patients (5.6%). In 22 patients (41.5%), new ischemic lesions were found on DWI, and in 21 filter devices (39.6%), a substantial amount of atheromatous plaque and/or fibrin was found. No clear relationship between the presence of debris captured by the filter device and new lesions detected by DWI was found (P = .087; odds ratio 3.067). Neuroprotected carotid artery stent placement will not avoid silent cerebral ischemia. Systematic microscopic analysis of debris captured by the filter device has no predictive value for potential cerebral ischemia after carotid artery stent placement.

  14. Personal Protection: The Way Forward (invited paper)

    International Nuclear Information System (INIS)

    Diffey, B.

    2000-01-01

    The perceived need for sunscreens with ever-increasing sun protection factors is unnecessary and leads to more confusion than clarity. Year-round sun protection achieved by the inclusion of ultraviolet (UV) filters in skin care products intended for daily use is not indicated for people living in northern Europe and may, in fact, be potentially harmful. Future needs for sun protection are likely to be influenced more by global warming than ozone depletion, and by the rising trend for overseas holidays to sunny destinations. (author)

  15. Proposal for the award of a blanket order contract for the supply of microprocessor-based protection and control devices for the CERN HV distribution network

    CERN Document Server

    2004-01-01

    This document concerns the award of a blanket contract for the supply of microprocessor-based protection and control devices for the CERN HV distribution network. The Finance Committee is invited to agree to the negotiation of a blanket order contract with SCHNEIDER ELECTRIC (PT), the lowest technically acceptable bidder after realignment, for the supply of microprocessor-based protection and control devices for the CERN HV distribution network for a total amount of 1 900 000 euros (2 924 128 Swiss francs), subject to revision for inflation after 1 January 2007. The rate of exchange used is that stipulated in the tender

  16. Toward Privacy-Preserving Personalized Recommendation Services

    Directory of Open Access Journals (Sweden)

    Cong Wang

    2018-02-01

    Full Text Available Recommendation systems are crucially important for the delivery of personalized services to users. With personalized recommendation services, users can enjoy a variety of targeted recommendations such as movies, books, ads, restaurants, and more. In addition, personalized recommendation services have become extremely effective revenue drivers for online business. Despite the great benefits, deploying personalized recommendation services typically requires the collection of users’ personal data for processing and analytics, which undesirably makes users susceptible to serious privacy violation issues. Therefore, it is of paramount importance to develop practical privacy-preserving techniques to maintain the intelligence of personalized recommendation services while respecting user privacy. In this paper, we provide a comprehensive survey of the literature related to personalized recommendation services with privacy protection. We present the general architecture of personalized recommendation systems, the privacy issues therein, and existing works that focus on privacy-preserving personalized recommendation services. We classify the existing works according to their underlying techniques for personalized recommendation and privacy protection, and thoroughly discuss and compare their merits and demerits, especially in terms of privacy and recommendation accuracy. We also identity some future research directions. Keywords: Privacy protection, Personalized recommendation services, Targeted delivery, Collaborative filtering, Machine learning

  17. Fast-response protection from high currents

    International Nuclear Information System (INIS)

    Novikov, A.A.

    1989-01-01

    Protection devices for power electronic equipment from shorting current are described. The device is shunted using spark gaps with minimal possible number of spark gaps to protect it. High fast-response (<100 ns) and operation voltage wide range (6-100 kV) are attained using Arkadiev-Marx generator-base trigger devices and air-core pulse transformer

  18. Comparison and Analysis of ISO/IEEE 11073, IHE PCD-01, and HL7 FHIR Messages for Personal Health Devices.

    Science.gov (United States)

    Lee, Sungkee; Do, Hyoungho

    2018-01-01

    Increasing use of medical devices outside of healthcare facilities inevitably requires connectivity and interoperability between medical devices and healthcare information systems. To this end, standards have been developed and used to provide interoperability between personal health devices (PHDs) and external systems. ISO/IEEE 11073 standards and IHE PCD-01 standard messages have been used the most in the exchange of observation data of health devices. Recently, transmitting observation data using the HL7 FHIR standard has been devised in the name of DoF (Devices on FHIR) and adopted very fast. We compare and analyze these standards and suggest that which standard will work best at the different environments of device usage. We generated each message/resource of the three standards for observed vital signs from blood pressure monitor and thermometer. Then, the size, the contents, and the exchange processes of these messages are compared and analyzed. ISO/IEEE 11073 standard message has the smallest data size, but it has no ability to contain the key information, patient information. On the other hand, PCD-01 messages and FHIR standards have the fields for patient information. HL7 DoF standards provide reusing of information unit known as resource, and it is relatively easy to parse DoF messages since it uses widely known XML and JSON. ISO/IEEE 11073 standards are suitable for devices having very small computing power. IHE PCD-01 and HL7 DoF messages can be used for the devices that need to be connected to hospital information systems that require patient information. When information reuse is frequent, DoF is advantageous over PCD-01.

  19. Pocket EZPIN device for healthcare IC cards to enhance the security and convenience of senior citizens.

    Science.gov (United States)

    Lai, Jiun-Tze; Hou, Ting-Wei

    2008-04-01

    An application that adopts smart cards often requires users to enter a PIN (Personal Identification Number) code. In Taiwan's healthcare system, a PIN is used to protect a card holder's private data. However, should one forget one's PIN, the procedure to set up a new PIN is inconvenient. There is a higher probability that senior citizens may forget their PINs. We propose a device which stores the PIN of the cardholder's Healthcare IC card. When the healthcare IC card reader requires the cardholder to enter his/her PIN, the cardholder pushes a button of the device to remotely sends the cardholder's encrypted PIN, for example by Infra Red. The device is designed to be low cost and easy to carry, and, hence, affordable to be a gift to senior citizens. Moreover, if the cardholder should forget to take the device with him/her, the card still works as normal. The device would be helpful in ensuring the public's privacy and convenience in Taiwan's healthcare system.

  20. The correlation between the use of personal protective equipment and level wild-type p53 of dental technicians in Surabaya

    Directory of Open Access Journals (Sweden)

    Puspa Dila Rohmaniar

    2017-03-01

    Full Text Available Background: Exposure of metals among dental technicians that come from the working environment can lead to the formation reactive oxygen species (ROS. ROS can cause mutations in the p53 gene (p53. The mutation is transversion mutation GuanineThymine. p53 mutations can lead to low expression of the wild-type p53 protein (p53. Wild-type p53 involved in many biological processes such as regulation of genes involved in cell cycle, cell growth after DNA damage, and apoptosis. However, exposure to metals among dental technicians can be prevented through the use of personal protective equipment (PPE during work. Purpose: The purpose of this study was to analyze the correlation between the use of personal protective equipment to wild-type p53 protein levels among dental technicians in Surabaya. Method: This study was observational analytic with cross sectional approach. 40 samples were taken by random sampling. Data were retrieved through interviews and observations. Wild-type p53 was analyzed from saliva with indirect ELISA method. Analysis of data used Kolmogorov Smirnov normality test and a Pearson correlation test. Value significance was p<0.05 (95% confidence level. Result: There was a significant association between the use of personal protective equipment with wild-type p53 levels with p=0.002 Conclusion: The use PPE properly is positively correlated with the wild-type p53 protein levels of dental technicians in Surabaya.

  1. Personal Flotation Devices Research. Volume 2. Research Report.

    Science.gov (United States)

    1978-01-01

    approval if it was not designed to the Type I, I , I , or IV criteria. This approach allows high life-saving effectiveness devices to enter the market if...Type X devices enjoy a market reception on the order of the reception given to Type III (the costs for Type Xs and Type Ills would be similar), an...addition to attempts to document the rate of wear of PFDs , previous researc h has measured various design features of PFDs and boater ’s attitudes . The

  2. Personalism for public health ethics

    Directory of Open Access Journals (Sweden)

    Carlo Petrini

    2010-06-01

    Full Text Available In public health ethics, as in bioethics, utilitarian approaches usually prevail, followed by Kantian and communitarian foundations. If one considers the nature and core functions of public health, which are focused on a population perspective, utilitarianism seems still more applicable to public health ethics. Nevertheless, faulting additional protections towards the human person, utilitarianism doesn't offer appropriate solutions when conflicts among values do arise. Further criteria must be applied to protect the fundamental principles of respect for human life. Personalism offers similar advantages to utilitarianism but warrants more protection to the human person. We suggest a possible adaptation of personalism in the specific field of public health by means of four principles: absolute respect for life or principle of inviolability; subsidiarity and the "minimum" mandatory principle; solidarity; justice and non discrimination.

  3. Personalism for public health ethics.

    Science.gov (United States)

    Petrini, Carlo; Gainotti, Sabina; Requena, Pablo

    2010-01-01

    In public health ethics, as in bioethics, utilitarian approaches usually prevail, followed by Kantian and communitarian foundations. If one considers the nature and core functions of public health, which are focused on a population perspective, utilitarianism seems still more applicable to public health ethics. Nevertheless, faulting additional protections towards the human person, utilitarianism doesn't offer appropriate solutions when conflicts among values do arise. Further criteria must be applied to protect the fundamental principles of respect for human life. Personalism offers similar advantages to utilitarianism but warrants more protection to the human person. We suggest a possible adaptation of personalism in the specific field of public health by means of four principles: absolute respect for life or principle of inviolability; subsidiarity and the "minimum" mandatory principle; solidarity; justice and non discrimination.

  4. Guidance notes for the protection of persons against ionising radiations arising from medical and dental use

    International Nuclear Information System (INIS)

    1988-01-01

    Guidance notes have been prepared by the NRPB, the Health Departments and the Health and Safety Executive for the protection of all persons against ionising radiations arising from medical and dental use. The guidance notes are a guide to good radiation protection practice consistent with regulatory requirements. The areas covered include medical and dental radiology, diagnostic X-ray equipment for medical and dental radiography, beam therapy and remotely controlled after-loading, brachytherapy, diagnostic and therapeutic uses of unsealed radioactive substances, diagnostic uses of sealed or other solid radioactive sources, patients leaving hospital after administration of radioactive substances, precautions after death of a patient whom radioactive substances have been administered, storage and movement of radioactive substances, disposal of radioactive waste and contingency planning and emergency procedures. (U.K.)

  5. Balancing autonomy and protection: A qualitative analysis of court hearings dealing with protective measures.

    Science.gov (United States)

    Fallon-Kund, Marie; Coenen, Michaela; Bickenbach, Jerome E

    Respect for individual autonomy is at the core of the Convention on the Rights of Persons with Disabilities (CRPD). However, the need to protect persons with disabilities, especially those with cognitive impairments and psychosocial conditions, from outright exploitation, violence and abuse is explicitly provided for in article 16. Legal authorities still decide on a daily basis upon the institution of measures, which aim to protect vulnerable persons and unavoidably impact on the autonomy of persons concerned, known as guardianship, curatorship or administration. Observations of court hearings, interviews with judges and analysis of written materials from the cantons of Geneva and Vaud in Switzerland as well as from Belgium - which all have differently composed authorities - were carried out in order to identify what influences authorities in decision-making processes regarding protective measures, and to explore how autonomy and protection can be balanced. We suggest pragmatic considerations that should not be ignored when trying to reach a balance between autonomy and protection from abuse, in line with the CRPD. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Main radiation protection actions for medical personnel as primary responders front of an event with radiological dispersive device; Principais acoes de protecao radiologica para equipe medica como primeiros respondedores frente a um evento com dispositivo de dispersao radiologica

    Energy Technology Data Exchange (ETDEWEB)

    Duque, Hildanielle Ramos

    2015-07-01

    After the terrorist attack in New York, USA, in 2001, there was a worldwide concern about possible attacks using radioactive material in conventional detonators, called as Radiological Dispersal Device (RDD) or 'dirty bomb'. Several studies have been and are being made to form a global knowledge about this type of event. As until now, fortunately, there has not been an event with RDD, the Goiania Radiological Accident in Brazil, 1987, is used as a reference for decision-making. Several teams with technical experts should act in an event with RDD, but the medical staffs who respond quickly to the event must be properly protected from the harmful effects of radiation. Based on the radiological protection experts performance during the Goiania accident and the knowledge from lessons learned of many radiological accidents worldwide, this work presents an adaptation of the radiation protection actions for an event with RDD that helps a medical team as primary responders. The following aspects are presented: the problem of radioactive contamination from the explosion of the device in underground environment, the actions of the first responders and evaluation of health radiation effects. This work was based on specialized articles and papers about radiological accidents and RDD; as well as personal communication and academic information of the Institute of Radiation Protection and Dosimetry. The radiation protection actions, adapted to a terrorist attack event with RDD, have as a scenario a subway station in the capital. The main results are: the use of the basic radiation protection principle of time because there is no condition to take care of a patient keeping distance or using a shielding; the use of full appropriate protection cloths for contaminating materials ensuring the physical safety of professionals, and the medical team monitoring at the end of a medical procedure, checking for surface contamination. The main conclusion is that all medical actions

  7. Personal medical electronic devices and walk-through metal detector security systems: assessing electromagnetic interference effects.

    Science.gov (United States)

    Guag, Joshua; Addissie, Bisrat; Witters, Donald

    2017-03-20

    There have been concerns that Electromagnetic security systems such as walk-through metal detectors (WTMDs) can potentially cause electromagnetic interference (EMI) in certain active medical devices including implantable cardiac pacemakers and implantable neurostimulators. Incidents of EMI between WTMDs and active medical devices also known as personal medical electronic devices (PMED) continue to be reported. This paper reports on emission measurements of sample WTMDs and testing of 20 PMEDs in a WTMD simulation system. Magnetic fields from sample WTMD systems were characterized for emissions and exposure of certain PMEDs. A WTMD simulator system designed and evaluated by FDA in previous studies was used to mimic the PMED exposures to the waveform from sample WTMDs. The simulation system allows for controlled PMED exposure enabling careful study with adjustable magnetic field strengths and exposure duration, and provides flexibility for PMED exposure at elevated levels in order to study EMI effects on the PMED. The PMED samples consisted of six implantable cardiac pacemakers, six implantable cardioverter defibrillators (ICD), five implantable neurostimulators, and three insulin pumps. Each PMED was exposed in the simulator to the sample WTMD waveforms using methods based on appropriate consensus test standards for each of the device type. Testing the sample PMEDs using the WTMD simulator revealed EMI effects on two implantable pacemakers and one implantable neurostimulator for exposure field strength comparable to actual WTMD field strength. The observed effects were transient and the PMEDs returned to pre-exposure operation within a few seconds after removal from the simulated WTMD exposure fields. No EMI was observed for the sample ICDs or insulin pumps. The findings are consistent with earlier studies where certain sample PMEDs exhibited EMI effects. Clinical implications were not addressed in this study. Additional studies are needed to evaluate potential PMED

  8. Protecting personal data in camera surveillance practices

    NARCIS (Netherlands)

    Dubbeld, L.

    2005-01-01

    This paper explores in which ways privacy (in particular, data protection principles) comes to the fore in the day-to-day operation of a public video surveillance system. Starting from current European legal perspectives on data protection, and building on an empirical case study, the meanings and

  9. Radiologic protection in intensive therapy units

    International Nuclear Information System (INIS)

    Andrea, H.; Juliana, C.; Gerusa, R.; Laurete, M.B.; Suelen, S.; Derech, Rodrigo D.A.

    2013-01-01

    The discovery of X-ray was a great achievement for humanity, especially for the medical community. In Intensive Care Units (ICUs), the RX tests, performed with mobile devices, add immense value to the diagnosis of inpatients who do not have the option to carry them out of bed. Following the technology and its improvements, fatalities arose from misuse of ionizing radiation, which mostly gave up for lack of knowledge of the biological effects caused by them, which leads to fear among professionals and often prevents a quick job and effectively by professionals of radiological techniques. The research it is a systematic review of the literature and justified by the scarcity of materials that reflect on the radiological protection in ICUs. For this study we found the Virtual Health Library (VHL) and Pubmed were indexed terms radiological protection and intensive care units, the search in Portuguese and English terms were used radiological protection and intensive care unit. The study aims to inform professionals of ICUs on the main aspects that refer to X-rays in hospital beds, the standards of radiological protection and personal protective equipment, thus avoiding possible damage to the biological health of workers, addressing subjects in rules and laws about the X radiation, emphasizing the protection of professionals in intensive care. It is clear, finally, that little research is conducted in the context of radiological protection of workers ICU's and this is a place that receives daily RX equipment, deserving more attention to protect the worker. (author)

  10. 30 CFR 57.15004 - Eye protection.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Eye protection. 57.15004 Section 57.15004... SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Personal Protection Surface and Underground § 57.15004 Eye protection. All persons shall wear safety glasses, goggles, or face...

  11. Mechanism of personal privacy protection based on blockchain%基于区块链的个人隐私保护机制

    Institute of Scientific and Technical Information of China (English)

    章宁; 钟珊

    2017-01-01

    Aiming at the problem of personal privacy protection in Interact car rental scenario,a personal privacy protection mechanism based on blockchain was proposed.Firstly,a framework for personal privacy protection based on blockchain was proposed for solving personal privacy issues exposed in the Internet car rental.Secondly,the design and definition of the model were given by participant profile,database design and performance analysis,and the framework and implementation of the model were expounded from the aspects of granting authority,writing data,reading data and revoking authority.Finally,the realizability of the mechanism was proved by the system development based on blockchain.%针对互联网租车场景中个人隐私保护问题,提出一种基于区块链的个人隐私保护机制.首先,针对互联网租车中暴露的个人隐私问题提出一个基于区块链的个人隐私保护解决方案框架;然后,通过参与者简介、数据库设计以及性能分析给出模型的设计和定义,并从授予权限、写入数据、读取数据和撤销权限等方面阐述该模型的框架和实现;最后,通过基于区块链的系统开发表明了该机制的可实现性.

  12. Balancing protection of public health and safety with the free movement of goods in the EU medical device sector : The case of ‘borderline products’ classification

    NARCIS (Netherlands)

    Tseliou, Tasoula

    2015-01-01

    In 2013, the CJEU ruled on the ‘Lyocentre’ case touching upon an important and contemporary issue in the EU Medical Device regime – the classification issue between medical devices and medicinal products. This problem is connected with the internal market v. protection of health dilemma as well as

  13. Quality control devices for intraoperative gamma probes: physical, technical and radiation protection aspects

    International Nuclear Information System (INIS)

    Varela, C.; Diaz, M.; Salvador, F.J.; Hernandez, M.; Jimenez, P.

    2008-01-01

    Now a day, radio guided surgery -a novelty in Nuclear Medicine- is increasingly used. The clinical efficiency of these procedures requires the existence of well-trained professionals and implementation of quality assurance programs. It is essential for achieving the main objective, which is an effective and safe surgical procedure, a reliable performance of the detection device. Probes' parameters must remain within the acceptance limits, so they should be checked periodically. NEMA Standards Publication NU 3-2004 'Performance Measurement and Quality Control Guidelines for Non-Imaging Intraoperative Gamma Probes' recommends 13 tests; although only 3 of them -sensibility in air, visual inspection and power source check- are considered as steadiness tests. Space resolution in a scatter medium is also a test that needs to be carried out. These tests are considerably complex since open radioactive sources are used into a liquid medium in most of the procedures. The immersion of the probe and of the radioactive sources in each case represents both risks of radioactive contamination, and of damages to the equipment. On the other hand, tests in air demand a good reproducibility. Since they are recommended be carried out before any surgery procedure, they also should be easy and quick. This paper presents 3 devices with its accessories for acceptance and quality control tests of intraoperative gamma probes. They were designed and built taking into consideration important aspects of radiological protection to handle the calibration sources and probes, both in air and into a scatter medium. These devices are designed to fit any kind of probe. Regulatory bodies as part of their instrument audits can also use them. (author)

  14. A person having ability in radiation protection: an original measure in comparison with the common rights for work safety

    International Nuclear Information System (INIS)

    Pasquier, J.L.; Vidal, J.P.

    1998-01-01

    In accordance with the regulations, any factory using ionising radiations is obliged to designate a person having having ability in radiation protection and entrusted with specific missions regarding safety for professional risks. This represents an original measure in comparison with the common rights for work safety. The decree whose became operative on 2 october 1986, about ten years ago and just before the reform of radiation protection standards, it seems important to store in memory the genesis and the goals of this prescription and to present the results. (authors)

  15. 30 CFR 56.15004 - Eye protection.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Eye protection. 56.15004 Section 56.15004... SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Personal Protection § 56.15004 Eye protection. All persons shall wear safety glasses, goggles, or face shields or other suitable...

  16. 14 CFR 139.335 - Public protection.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Public protection. 139.335 Section 139.335... Operations § 139.335 Public protection. (a) In a manner authorized by the Administrator, each certificate... persons or vehicles; and (2) Reasonable protection of persons and property from aircraft blast. (b...

  17. Diplomatic Protection

    OpenAIRE

    Režná, Jana

    2006-01-01

    Final thesis Topic: Diplomatic protection Thesis supervisor: JUDr. Vladimír Balaš, CSc. Student: Marek Čermák Thesis on the topic of diplomatic protection deals with the granting of exercise of diplomatic protection by the states and is divided into seven chapters which follow each other. The first chapter describes the diplomatic protection and its historical foundations. The second chapter focuses on the possibility of exercise of diplomatic protection in respect of natural persons and the ...

  18. Eye Protection in Kansas Schools.

    Science.gov (United States)

    Hay, Kenneth M.; And Others

    A law passed by a state legislature requires that students in industrial arts shops and science laboratories must wear eye protective devices. Explanatory material presents the text of the bill and guidelines for implementation, including--(1) types of eye hazards, (2) types of protective devices, (3) administrating eye safety equipment, (4)…

  19. Nuclear fast neutron reactor cooled by a liquid metal and of which internal structures are equipped with a thermal protection device

    International Nuclear Information System (INIS)

    Lemercier, G.; Lions, N.

    1986-01-01

    The internal structures of a nuclear fast neutron reactor are covered at least partially, on the most hot side, by a thermal protection device. This device comprises modular plates arranged end to end with a certain play between themselves and taking approximately the shape of the internal structures. Each plate is fixed in its center on the internal structures by a stud. A small plate fixed at one of the corners of each plate and covering partially the adjacent plates ensures the safety fixing of these ones [fr

  20. The right to the protection of personal data between law and constitution

    Directory of Open Access Journals (Sweden)

    Maria Carmen Aguilar Del Castillo

    2016-06-01

    Full Text Available The aim of the article is, on the one hand, to analyze the content and scope of fundamental right to the protection of personal data, provided by art. 18.4 of the Spanish Constitution; on the other, to decline this right in the context of the employment relationship starting from the interpretation given by the Spanish Constitutional Court in judgment no. 39/2016. The contrast between this right and the freedom of enterprise, which is realized in the power of organization, control and supervision of work performance, is resolved by the Constitutional Court in the light of the principles of proportionality, suitability and necessity. The outcome of the balancing leads the Constitutional Court to establish the prevalence of the entrepreneurial freedom on the right to privacy of the employee.

  1. Personal Beacon

    Science.gov (United States)

    2000-01-01

    The MicroPLB (personal locator beacon) is a search and rescue satellite-aided tracking (SARSAT) transmitter. When activated it emits a distress signal to a constellation of internationally operated satellites. The endangered person's identity and location anywhere on Earth is automatically forwarded to central monitoring stations around the world. It is accurate to within just a few meters. The user uses the device to download navigation data from a global positioning satellite receiver. After the download is complete, the MicroPLB functions as a self-locating beacon. Also, it is the only PLB to use a safe battery. In the past, other PLB devices have used batteries that have enough volatility to explode with extreme force. It was developed by Microwave Monolithic, Inc. through SBIR funding from Glenn Research Center and Goddard Space Flight Center.

  2. How conservative is routine personal dosimetry monitoring in diagnostic radiology?

    International Nuclear Information System (INIS)

    Boetticher, H. von; Lachmund, J.; Hoffmann, W.

    2007-01-01

    Purpose: Dose values obtained by official personal radiation exposure monitoring are often considered equivalent to the effective dose of a person. This paper provides estimates of the extent of deviation between the two dose concepts under various conditions. Materials and Methods: Doses for patients and personnel were measured using thermoluminescence dosimeters for five different geometries at three work settings in a radiology department. Patients and personnel were simulated with anthropomorphic phantoms. Different types of protective clothing as well as permanent protection shields were considered in the calculations. Results: Dose values obtained by official personal dose monitoring are conservative only for specific radiation protection situations. With state-of-the-art personal protective equipment (wrap-around style lead apron with thyroid shield), the ratio between effective dose and personal dose varies between 0.6 and 1.25. Without thyroid protection the official personal dose systematically underestimates the effective dose: for protective clothing with 0.5 mm lead equivalent without thyroid shielding, the effective dose exceeds the personal dose by factors between 1.7 and 3.1. If protective clothing with lead equivalent 0.35 mm is used, this factor varies between 1.1 and 1.82. (orig.)

  3. The right to life and criminal-law protection of the human person in the Western Balkans

    Directory of Open Access Journals (Sweden)

    Etlon Peppo

    2015-07-01

    Full Text Available The basic principle for which a democratic governance stands, are expressed in the “Declaration of Independence of the United States of America with the words of Thomas Jefferson: “We hold these truths to be self-evident, that all men are created equal, that they are endowed by their Creator with certain unalienable Rights that among these are Life, Liberty and the Pursuit of Happiness. That to secure these rights, Governments are instituted among Men, deriving their just powers from the consent of the governed” The government of a democratic state does not exist to recognize the basic human rights, but to respect and guarantee the protection of these rights that any person possesses and benefits due to his existence starting from the most important right: The right to life, which is faced against the duty of the state for the protection of the human person’s life! In this sense this article analyzes the criminal-law protection of life in the Western Balkans.

  4. Personal Privacy Protection in Big Data Era%大数据时代个人隐私的保护

    Institute of Scientific and Technical Information of China (English)

    张永兵

    2016-01-01

    近年来,以云计算为基础平台的大数据时代正式到来,大数据因蕴藏有巨大的商业价值而使不法分子想方设法盗取个人隐私数据,从而影响用户的正常生活。本文通过分析大数据时代个人隐私安全面临的严峻挑战,对个人隐私保护所采用的技术措施进行总结,并提出了个人或企业应遵守的法律和行业规范,最后探索了个人隐私保护的进一步研究方向。%In recent years, the era of big data based on cloud computing platform officially arrived, and big data contains a huge commercial value and makes the criminals try to steal personal privacy data, thus affecting the normal life of the user. By analyzing the challenges faced by the privacy security in the era of big data, summarize the technical measures adopted in the protection of personal privacy, put forward the laws and industry standards the individual or enterprise should abide by, and finally explore the direction of further research on the protection of personal privacy.

  5. Effect of health education based on BASNEF pattern on use of personal protective respiratory equipment in Ahvaz carbon block factory workers, 2009

    Directory of Open Access Journals (Sweden)

    M Solhi

    2012-11-01

    Full Text Available   Background and aims: Respiratory diseases due to work with 50 million annually incidence included one third of all occupational diseases and it is one of the main causes of absenteeism from work in workers. Some occupational diseases can be prevented with personal protective equipment. BASNEF model is one of the effective health education and safety training models for workers. The aim of this study was to determine the effect of educational intervention based on BASNEF pattern on increasing the use of personal protective respiratory equipment among carbon black factory workers , where many air pollutants such as carbon block exists. Methods: In this study the intervention curriculum based on BASNEF pattern administrated on 100 (experimental and control Ahvaz carbon block factory workers. Data were collected by questionnaires. The data were analyzed by Independent T, χ square and Pearson correlation co- efficient using SPSS version16.   Results : After the intervention, the mean scores of knowledge, attitude, intention, and enabling factors showed significant increase in experimental group in comparison of control group (p<0.00001. In addition, the mean score of subjective norms in experimental and control groups showed no significant differences. Conclusion: The educational program based on BASNEF pattern was effective in improving the use of respiratory personal protective equipment in Ahvaz carbon block factory workers 

  6. [Electronic Device for Retinal and Iris Imaging].

    Science.gov (United States)

    Drahanský, M; Kolář, R; Mňuk, T

    This paper describes design and construction of a new device for automatic capturing of eye retina and iris. This device has two possible ways of utilization - either for biometric purposes (persons recognition on the base of their eye characteristics) or for medical purposes as supporting diagnostic device. eye retina, eye iris, device, acquisition, image.

  7. Accident with radioactive substances in laboratory. An exercise during the education of persons in radiation protection, who are working with open radioactive sources

    International Nuclear Information System (INIS)

    Stolze, B.

    2003-01-01

    In spite of carefulness it is possible,that contamination occur by handling unscaled radioactive sources or in case of an accident. It is demonstrated in an exercise managing an accident with unscaled radioactive sources. The persons, who are educated in radiation protection for handling unsealed radioactive sources, must have knowledge of theoretical regulations of the radiation protection law and of the limits in radiation protection. Also they have to know the handling to reduce possible contamination. They have to be able to calculate the dose of skin contamination. In my lecture I give some information on regulations of accidents with radioactive sources in Germany and a scenario of an accident and I explain, what is to do to manage this event. A person opened an ampoule. The activity splashed and contaminated the person's hand, arm and face. Also in the room there was a contamination. The desk and the floor were contaminated. There were 50 MBq P-32 as NaH 2 P''32O 3 in water solution, I give a report on practices in our courses, which the participants have to do. The radiological experts have to decontaminate the skin and they have to calculate the skin-dose and to give the information to the authorities. (Author) 4 refs

  8. Order of the 6 December 2013 related to modalities of training of the Competent Radiological Protection Person, and of certification of training organization

    International Nuclear Information System (INIS)

    Combrexelle, J.D.; Gandil, P.; Ligeard, C.

    2013-01-01

    This order issued by the French Ministry of labour, employment, professional training and social dialogue aims at defining the modalities and contents of training of competent radiological protection persons, as well as the modalities of certification of certificating organizations and of certification of training organizations. As far as the training of the competent radiological protection person, the order defines the scope, training levels, activity sectors, the basic training, the knowledge control and validation process, the certification of the person, the extension of the level or scope of this certification, the certification renewal. As far as the certificating body and the certification of the training organization are concerned, the order addresses the certification instruction modalities, additional requirements for certificating bodies, requirements related to training organizations. Other arrangements and issues are indicated related to equivalencies, implementation, abrogation and transitory arrangements. Additional information regarding the content of training courses and certification processes is provided in appendix

  9. 46 CFR 111.51-3 - Protection of vital equipment.

    Science.gov (United States)

    2010-10-01

    ...-GENERAL REQUIREMENTS Coordination of Overcurrent Protective Devices § 111.51-3 Protection of vital equipment. (a) The coordination of overcurrent protective devices must be demonstrated for all potential... 46 Shipping 4 2010-10-01 2010-10-01 false Protection of vital equipment. 111.51-3 Section 111.51-3...

  10. Device- and system-independent personal touchless user interface for operating rooms : One personal UI to control all displays in an operating room.

    Science.gov (United States)

    Ma, Meng; Fallavollita, Pascal; Habert, Séverine; Weidert, Simon; Navab, Nassir

    2016-06-01

    In the modern day operating room, the surgeon performs surgeries with the support of different medical systems that showcase patient information, physiological data, and medical images. It is generally accepted that numerous interactions must be performed by the surgical team to control the corresponding medical system to retrieve the desired information. Joysticks and physical keys are still present in the operating room due to the disadvantages of mouses, and surgeons often communicate instructions to the surgical team when requiring information from a specific medical system. In this paper, a novel user interface is developed that allows the surgeon to personally perform touchless interaction with the various medical systems, switch effortlessly among them, all of this without modifying the systems' software and hardware. To achieve this, a wearable RGB-D sensor is mounted on the surgeon's head for inside-out tracking of his/her finger with any of the medical systems' displays. Android devices with a special application are connected to the computers on which the medical systems are running, simulating a normal USB mouse and keyboard. When the surgeon performs interaction using pointing gestures, the desired cursor position in the targeted medical system display, and gestures, are transformed into general events and then sent to the corresponding Android device. Finally, the application running on the Android devices generates the corresponding mouse or keyboard events according to the targeted medical system. To simulate an operating room setting, our unique user interface was tested by seven medical participants who performed several interactions with the visualization of CT, MRI, and fluoroscopy images at varying distances from them. Results from the system usability scale and NASA-TLX workload index indicated a strong acceptance of our proposed user interface.

  11. Investigation of Vehicle Rear Under Run Protection Device (RUPD) Using Aluminium Foam

    Science.gov (United States)

    Nagaraj Goud, B.; pachori, Avinash

    2017-08-01

    Whenever the passenger cars meet with accidents with the heavy duty truck from rear, it will tend to penetrate under the truck bed called truck trailer under-ride crash. This is responsible for the thousands of accidents, causing severe injuries and spot death. This is mostly due to the lack of effective guarding system. The Present paper gives an importance on energy absorption mechanism of a Rear under Run Protection Device (RUPD) under crash effect of the truck. The aim of the study is to replace Steel RUPD with aluminum foam, which promises an improvement of vehicle crashworthiness as well as to reduce weight of the vehicle. The aluminum foam is selected due to the high specific strength and specific stiffness. This inborn character makes it a promising candidate in the modern lightweight structures in the automotive engineering which can contribute to the improvement of mileage in addition to safety of the occupants.

  12. Anti-malware software and medical devices.

    Science.gov (United States)

    2010-10-01

    Just as much as healthcare information systems, medical devices need protection against cybersecurity threats. Anti-malware software can help safeguard the devices in your facility-but it has limitations and even risks. Find out what steps you can take to manage anti-malware applications in your devices.

  13. Fifth meeting of persons competent in radiation protection; Cinquiemes rencontres des personnes competentes en radioprotection

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    During this meeting will successively be approached: the statutory frame, the practical guide for the realization of the dosimetry studies of work stations presenting a risk of exposure to ionizing radiations, a study of post in conventional and interventional radiology, study of post in interventional cardiology, the roles and the missions of the P.C.R. (person competent in radiation protection) in a subcontractor company in I.N.B. (base nuclear installation), the application of the zoning order for the activities of industrial radiography, the evolution of the statutory measures in protection of the workers against the dangers of ionizing radiations, all which concerns the P.C.R. (training, missions, certification, educational role), the controls of radioprotection, the external controls of radioprotection, the surveillance of working zones, surveillance of effluents,management of the radioactive waste and effluents, classification of the personnel and the surveillance of the exposure, dosimetry by radio photo luminescence, the systeme S.I.S.E.R.I.. (N.C.)

  14. Privacy-Preserving Meter Report Protocol of Isolated Smart Grid Devices

    Directory of Open Access Journals (Sweden)

    Zhiwei Wang

    2017-01-01

    Full Text Available Smart grid aims to improve the reliability, efficiency, and security of the traditional grid, which allows two-way transmission and efficiency-driven response. However, a main concern of this new technique is that the fine-grained metering data may leak the personal privacy information of the customers. Thus, the data aggregation mechanism for privacy protection is required for the meter report protocol in smart grid. In this paper, we propose an efficient privacy-preserving meter report protocol for the isolated smart grid devices. Our protocol consists of an encryption scheme with additively homomorphic property and a linearly homomorphic signature scheme, where the linearly homomorphic signature scheme is suitable for privacy-preserving data aggregation. We also provide security analysis of our protocol in the context of some typical attacks in smart grid. The implementation of our protocol on the Intel Edison platform shows that our protocol is efficient enough for the physical constrained devices, like smart meters.

  15. Modeling Speech Level as a Function of Background Noise Level and Talker-to-Listener Distance for Talkers Wearing Hearing Protection Devices

    Science.gov (United States)

    Bouserhal, Rachel E.; Bockstael, Annelies; MacDonald, Ewen; Falk, Tiago H.; Voix, Jérémie

    2017-01-01

    Purpose: Studying the variations in speech levels with changing background noise level and talker-to-listener distance for talkers wearing hearing protection devices (HPDs) can aid in understanding communication in background noise. Method: Speech was recorded using an intra-aural HPD from 12 different talkers at 5 different distances in 3…

  16. Seventh meeting of radiation protection skilled persons; Septiemes rencontres des personnes competentes en radioprotection

    Energy Technology Data Exchange (ETDEWEB)

    Juhel, Th.; Briandchamplong, J.; Gambini, D.J.; Ammerich, M.; Aubert, B.; Barbey, P.; Biau, A.; Bruchet, H.; Capelle, M.H.; Flon, E.; Gauron, Ch.; Gravelotte, D.; Guerin, Ch.; Le Denmat, D.; Lemoine, Th.; Lombard, J.; Lucas, St.; Menechal, Ph.; Mignien, S.; Million, M.; Mozziconacci, J.G.; Prevot, S.; Radecki, J.J.; Rigaud, S.; Taillandier, P.; Timbert, M.; Vidal, J.P.; Bardelay, Ch.; Lahaye, Th.; Balduyck, S.; Chasson, E.; Rehel, J.L.; Chatellier, Ch.; Barret, Ch.; Guersen, J.; Degrange, J.P.; Sevestre, B.; Lahaye, Th.; Rodde, S.; Marchal, C.; Lefaure, Ch.; Bouk' il, H.; Gneiting, M.; Auboiroux, B.; Riedel, A.; Feuardent, J.; Scanff, P.; Bof, M.; Lochard, J.; Godet, J.L.

    2011-07-01

    This document gathers the slides of the available presentations given during these conference days. Twenty-three presentations out of 25 are assembled in the document and deal with: 1 - the evolution of workers' international protection rules against ionizing radiation risks (C. Bardelay); 2 - presentation of the report of the working group on radiation protection (P. Barbey); 3 - position of the French nuclear safety authority and of the labor general direction about the position of permanent expert groups in radiation protection concerning the expected evolutions in the occupation and training of radioprotection skilled persons (RSP), (T. Lahaye); 4 - experience feedback: RSP in surgery operating theater - a sometimes delicate intervention (S. Balduyck); 5 - workplace analysis in dental surgery: constraints and specificities (D. Le Denmat); 6 - workplace analysis: tritium atmospheric contamination (S. Rigaud); 7 - revision of the NFC 15-160 standard relative to radiology facilities (J.L. Rehel); 8 - example of area tele-dosimetry usage - the Pitie Salpetriere hospital experiment (C. Chatellier and C. Barret); 9 - contribution of radio-attenuation lead gloves in interventional radiology (J. Guersen); 10 - zoning in the medical domain: encountered problems typology and evaluation of possible solutions (Degrange, J.P.); 11 - management of used sealed sources distributed by the CEA and CISBIO (B. Sevestre); 12 - how to perform a measurement in radiation protection - how about measurement uncertainty (M. Ammerich); 13 - national campaign of control about the application of workers radiation protection rules (T. Lahaye); 14 - transparency and inspection approach in local nuclear applications: gamma-graphy, research, nuclear medicine, interventional radiography and radiotherapy (S. Rodde and C. Marchal); 15 - local/regional networks of RSPs and radiation protection actors: 2008 audit results and recent evolutions (C. Lefaure); 16 - role and missions of the external

  17. Management of risk factors in the selection and use of PPE [personal protective equipment] on hazardous waste sites

    International Nuclear Information System (INIS)

    Kemplin, M.G.

    1988-01-01

    Industrial hygiene managers working in the hazardous waste area face daily decisions concerning appropriate levels of personal protective equipment (PPE) for hazards expected on various waste site projects. Typical hazards include exposures to toxic dust, chemical vapors, toxic gases, splashes of corrosive or toxic substances, radioactive materials and high noise levels. Managers who are experienced in this area recognize that each item of PPE can represent potential hazards in its own right. For example, full-face respirators typically restrict peripheral vision and can impede proper communications. In high ambient temperature conditions, coated protective suits can represent significant heat stress concerns, etc. Accordingly, this paper reviews health and safety management decision-making in this regard

  18. Report by the work-group on 'safety of medical devices emitting ionizing radiations'. Articulation of radiation protection requirements of the 97/43/Euratom directive and IAEA recommendations with the essential requirements of the 93/42/CEE directive related to medical devices used in external radiotherapy

    International Nuclear Information System (INIS)

    2010-01-01

    As some dysfunctions and events had been reported in 2007 and 2008 in field of radiotherapy, this report aims at clarifying the articulation between the different European regulations concerning medical devices emitting ionizing radiations and radiation protection. The authors report a survey with device manufacturers, and analyze the content of the different regulations and recommendations. Then, the authors recommend and propose a set of actions related to the IAEA requirements and recommendations, to CE marking requirements, and to new radiation protection and safety requirements present in the Euratom directive

  19. Security Frameworks for Machine-to-Machine Devices and Networks

    Science.gov (United States)

    Demblewski, Michael

    Attacks against mobile systems have escalated over the past decade. There have been increases of fraud, platform attacks, and malware. The Internet of Things (IoT) offers a new attack vector for Cybercriminals. M2M contributes to the growing number of devices that use wireless systems for Internet connection. As new applications and platforms are created, old vulnerabilities are transferred to next-generation systems. There is a research gap that exists between the current approaches for security framework development and the understanding of how these new technologies are different and how they are similar. This gap exists because system designers, security architects, and users are not fully aware of security risks and how next-generation devices can jeopardize safety and personal privacy. Current techniques, for developing security requirements, do not adequately consider the use of new technologies, and this weakens countermeasure implementations. These techniques rely on security frameworks for requirements development. These frameworks lack a method for identifying next generation security concerns and processes for comparing, contrasting and evaluating non-human device security protections. This research presents a solution for this problem by offering a novel security framework that is focused on the study of the "functions and capabilities" of M2M devices and improves the systems development life cycle for the overall IoT ecosystem.

  20. 29 CFR 1918.101 - Eye and face protection.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Eye and face protection. 1918.101 Section 1918.101 Labor... that protective eye and face devices comply with any of the following consensus standards: (A) ANSI Z87... face protection devices that are constructed in accordance with one of the above consensus standards...

  1. Audit Report on "Protection of the Department of Energy's Unclassified Sensitive Electronic Information"

    Energy Technology Data Exchange (ETDEWEB)

    None

    2009-08-01

    The Department of Energy and its contractors store and process massive quantities of sensitive information to accomplish national security, energy, science, and environmental missions. Sensitive unclassified data, such as personally identifiable information (PII), official use only, and unclassified controlled nuclear information require special handling and protection to prevent misuse of the information for inappropriate purposes. Industry experts have reported that more than 203 million personal privacy records have been lost or stolen over the past three years, including information maintained by corporations, educational institutions, and Federal agencies. The loss of personal and other sensitive information can result in substantial financial harm, embarrassment, and inconvenience to individuals and organizations. Therefore, strong protective measures, including data encryption, help protect against the unauthorized disclosure of sensitive information. Prior reports involving the loss of sensitive information have highlighted weaknesses in the Department's ability to protect sensitive data. Our report on Security Over Personally Identifiable Information (DOE/IG-0771, July 2007) disclosed that the Department had not fully implemented all measures recommended by the Office of Management and Budget (OMB) and required by the National Institute of Standards and Technology (NIST) to protect PII, including failures to identify and encrypt PII maintained on information systems. Similarly, the Government Accountability Office recently reported that the Department had not yet installed encryption technology to protect sensitive data on the vast majority of laptop computers and handheld devices. Because of the potential for harm, we initiated this audit to determine whether the Department and its contractors adequately safeguarded sensitive electronic information. The Department had taken a number of steps to improve protection of PII. Our review, however

  2. Radiation leaking protection device

    International Nuclear Information System (INIS)

    Sunami, Yoshio; Mitsumori, Kojiro

    1980-01-01

    Purpose: To prevent radioactivity from leaking outside of a reactor container by way of pipeways passing therethrough, by supplying pressurized fluid between each of a plurality of valves for separating the pipeways. Constitution: Pressurized fluid is supplied between each of a plurality of valves for separating pipeways. For instance, water in a purified water tank is pressurized by a pressure pump and the pressure of the pressurized water is controlled by a differential pressure detector, a pressure controller and a pressure control valve. In the case if a main steam pipe is ruptured outside of the reactor container or to be repaired, the separation valves are wholly closed and then the pressurizing device is actuated to supply pressurized water containing no radioactivity from the purified water tank to the position between the valves. The pressure in the pressurized water is controlled such that it is always higher by a predetermined level than the pressure in the reactor. This prevents the radioacitivity in the reactor core from leaking outside of the container passing through the valves, whereby radiation exposure in the working can be reduced and the circumferential contamination upon accident of pipeway rupture can be decreased. (Kawakami, Y.)

  3. An application to estimate the cyber-risk detection skill of mobile device users

    NARCIS (Netherlands)

    Schaff, Guillaume; Harpes, Carlo; Martin, Romain; Junger, Marianne; Berntzen, Lasse; Böhm, Stephan

    2013-01-01

    According to experts’ predictions, mobile devices (smartphones, tablet computers) will replace the widespread personal computer by 2017 for personal and work tasks (emergence of BYOD). In parallel, the expert community has observed an increase of cyber-attacks against mobile devices. Mobile device

  4. 21 CFR 820.130 - Device packaging.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Device packaging. 820.130 Section 820.130 Food and... QUALITY SYSTEM REGULATION Labeling and Packaging Control § 820.130 Device packaging. Each manufacturer shall ensure that device packaging and shipping containers are designed and constructed to protect the...

  5. High performance bio-integrated devices

    Science.gov (United States)

    Kim, Dae-Hyeong; Lee, Jongha; Park, Minjoon

    2014-06-01

    In recent years, personalized electronics for medical applications, particularly, have attracted much attention with the rise of smartphones because the coupling of such devices and smartphones enables the continuous health-monitoring in patients' daily life. Especially, it is expected that the high performance biomedical electronics integrated with the human body can open new opportunities in the ubiquitous healthcare. However, the mechanical and geometrical constraints inherent in all standard forms of high performance rigid wafer-based electronics raise unique integration challenges with biotic entities. Here, we describe materials and design constructs for high performance skin-mountable bio-integrated electronic devices, which incorporate arrays of single crystalline inorganic nanomembranes. The resulting electronic devices include flexible and stretchable electrophysiology electrodes and sensors coupled with active electronic components. These advances in bio-integrated systems create new directions in the personalized health monitoring and/or human-machine interfaces.

  6. 49 CFR 178.337-10 - Accident damage protection.

    Science.gov (United States)

    2010-10-01

    ... failure of the sacrificial device must leave the protected lading protection device and its attachment to the cargo tank wall intact and capable of retaining product. [Order 59-B, 30 FR 581, Jan. 16, 1965...

  7. Hearing protection use in manufacturing workers: A qualitative study

    Directory of Open Access Journals (Sweden)

    Ravi K Reddy

    2012-01-01

    Full Text Available Occupational noise is a significant contributor to disabling hearing loss worldwide. Noise-induced hearing loss (NIHL has resulted in huge human and economic consequences costing New Zealand approximately $53M annually and rising. A high proportion of hearing loss claims are made by workers in the manufacturing sector. Hearing protection devices (HPDs are used together with engineering and administrative controls to minimize noise exposure and to prevent hearing loss. Unfortunately, inconsistent and improper use of HPDs has hindered efforts to prevent NIHL. The purpose of this study was to understand the factors that influence the use of HPDs amongst a group of manufacturing workers in New Zealand. A purposive sample of twenty-five workers was recruited to take part in semi-structured interviews. The open-ended questions were aimed at exploring the participants′ knowledge, attitude, beliefs, and behavior towards noise and HPDs. The data were analyzed using conventional content analysis and key themes emerged in relation to HPD use. Themes that emerged from the interviews either supported good hearing protection behavior or acted as barriers against it. Five major themes, (perception of noise, hearing preservation, reluctance to use HPDs, workplace interaction, and value of hearing and sub-themes described various factors that influence hearing protection use. Both personal and environmental factors influence the use of HPDs. Based on this study, personal and environmental factors need to be targeted for further research using ecological models to develop interventions that promote HPD use amongst workers.

  8. Distal protection in cardiovascular medicine: current status.

    Science.gov (United States)

    Ali, Onn Akbar; Bhindi, Ravinay; McMahon, Aisling C; Brieger, David; Kritharides, Leonard; Lowe, Harry C

    2006-08-01

    Iatrogenic and spontaneous downstream microembolization of atheromatous material is increasingly recognized as a source of cardiovascular morbidity and mortality. Devising ways of reducing this distal embolization using a variety of mechanical means--distal protection--is currently under intense and diverse investigation. This review therefore summarizes the present status of distal protection. It examines the problem of distal embolization, describes the available distal protection devices, reviews those areas of cardiovascular medicine where distal protection devices are being investigated, and discusses potential future developments.

  9. Fall Protection Introduction, #33462

    Energy Technology Data Exchange (ETDEWEB)

    Chochoms, Michael [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-23

    The proper use of fall prevention and fall protection controls can reduce the risk of deaths and injuries caused by falls. This course, Fall Protection Introduction (#33462), is designed as an introduction to various types of recognized fall prevention and fall protection systems at Los Alamos National Laboratory (LANL), including guardrail systems, safety net systems, fall restraint systems, and fall arrest systems. Special emphasis is given to the components, inspection, care, and storage of personal fall arrest systems (PFASs). This course also presents controls for falling object hazards and emergency planning considerations for persons who have fallen.

  10. A Survey of Indoor Positioning Systems for Wireless Personal Networks

    NARCIS (Netherlands)

    Gu, Y.; Lo, A.; Niemegeers, I.

    2009-01-01

    Recently, indoor positioning systems (IPSs) have been designed to provide location information of persons and devices. The position information enables location-based protocols for user applications. Personal networks (PNs) are designed to meet the users' needs and interconnect users' devices

  11. Advances in the simulation of personal protective equipment for the mitigation of exposure to radioactive particulates

    International Nuclear Information System (INIS)

    Roeterink, M.J.; Kelly, D.G.; Dickson, E.F.G; Corcoran, E.C.

    2014-01-01

    Airborne radioactive particulates represent a significant potential hazard to first responders in nuclear related incidents. Personal protective equipment (PPE), in particular radio-opaque fabrics, can be used to reduce wearer exposure to the emitted radiation, but do not offer complete protection. The objective of this project is to create a realistic dosimetric model of the human arm, protected by a sleeve, which can eventually be developed into a tool to assess the full-body dose imparted to the wearer in the event of radiological particulate exposure. A two-fold approach will be employed whereby: (1) a particulate transport model will be used to determine the regional radioactive particulate concentrations; and (2) these concentration data will then be incorporated into a dosimetric model that will use the Monte Carlo N-Particle (MCNP) transport code to determine the dose imparted to the tissue. Benchmarking experiments will be carried out to validate the results generated by the computer models. Such experimentation will be conducted for both the particulate transport and dosimetric models. Model advancement aims to consider whole body dose and will be invaluable in the development of future radiation exposure policies and procedures. (author)

  12. Medical device risk management and its economic impact

    Directory of Open Access Journals (Sweden)

    Katerina Krsteva Jakimovska

    2013-10-01

    Full Text Available The importance of medical devices in everyday users/patients lives is imensse. This is the reason why emphasis must be put on safety during their use. Satisfactory safety level can be achived by implementation of quality and risk management standards. Medical device manufacturers must learn to deal with the potential risks by using theoretical and practical examples and measures in order to protect their users/patients and themselves from suffering huge losses arising from adverse events or recall of their products. The best moment for implementation of risk management methods and analysis begins from the device design and development through manufacturing, sales and distribution. These way medical device manufacturers will succseed in protecting their users/patients from serious adverse events and at the same time protect their brand and society status, while minimizing economic losses.

  13. 14 CFR 91.21 - Portable electronic devices.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Portable electronic devices. 91.21 Section... electronic devices. (a) Except as provided in paragraph (b) of this section, no person may operate, nor may any operator or pilot in command of an aircraft allow the operation of, any portable electronic device...

  14. State duties of protection and fundamental rights

    Directory of Open Access Journals (Sweden)

    C Starck

    2000-05-01

    Full Text Available Duties of protection are duties of the state to protect certain legal interests of its citizens. They cover the interests of life, health, freedom and property and also protect some other interests and certain constitutionally recognised institutions. State duties of protection must be considered in connection with fundamental rights. The foundations of modern constitutionalism and attendant procedures are essential to develop guidelines for a constructive critique of the jurisprudence of the Constitutional Court. This is done with reference to the recent history of France, Germany and England. The historical excursus reveals that a single theory underlies the variety of constitutional states. The development of the constitutional state gave rise to the significance of the preservation of freedom through the maintenance of law and the separation of powers. This has given rise to various legal devices, based also in part on experience with moderate rule and earlier theories of the imperium limitatum.A textual analysis of the German Basic Law is undertaken to determine whether and how the duties of protection are expressly created. Furthermore, the duties that have been discovered in the Basic Law by the Federal Constitutional Court are considered. These duties include the protection of human life and health, personal freedom, the right to autonomous development of one's personality, freedom of science, research and teaching, marriage and the family, children, mothers, professional freedom, property and the protection of German nationals against foreign states. Finally the justification of such duties and the constitutional control of the manner of protection are considered.In a final section a critique of relevant constitutional jurisprudence is undertaken. It is argued that claims to protection cannot be directly binding law. They presuppose legislation. If statutory protection is connected with infringements of third-party fundamental rights

  15. An investigation into the effect of protective devices on the dose to radiosensitive organs in the head and neck

    International Nuclear Information System (INIS)

    Marshall, N.W.; Faulkner, K.; Clarke, P.

    1992-01-01

    A series of experiments were performed to determine the dose reduction afforded to radiosensitive organs in the head and neck by various protective devices. These included spectacles with plastic, standard glass, photochromic and lead-glass lenses, a thyroid collar and a lead-acrylic face mask. The measurements were performed using an anthropomorphic phantom loaded with lithium fluoride thermoluminescent dosemeters, in conditions realistic of clinical practice. Irradiations were performed using scattered radiation produced by a pelvic phantom, for X-ray beams generated at 80 kVp and 110 KVp. Also presented is the ratio of organ dose to dose to the bridge of the nose for thyroid, oesophagus, brain and sinuses, as measured for the case of no head or neck protection. (author)

  16. Protection of electronic circuits from overvoltages

    CERN Document Server

    Standler, Ronald B

    1989-01-01

    Practical rules and strategies designed to protect electronic systems from damage by transient overvoltages include symptoms and threats, remedies, protective devices and their applications, and validation of protective measures. 1989 edition.

  17. Child protection workers dealing with child abuse: The contribution of personal, social and organizational resources to secondary traumatization.

    Science.gov (United States)

    Dagan, Shlomit Weiss; Ben-Porat, Anat; Itzhaky, Haya

    2016-01-01

    The present study compared secondary traumatization among child protection social workers versus social workers employed at social service departments. In addition, based on Conservation of Resources (COR) theory, the study examined the contribution of working in the field of child protection as well as the contribution of background variables, personal resources (mastery), and resources in the workers' social and organizational environment (social support, effectiveness of supervision, and role stress) to secondary traumatization. The findings indicate that levels of mastery and years of work experience contributed negatively to secondary traumatization, whereas exposure to child maltreatment, trauma history, and role stress contributed positively to secondary traumatization. However, no significant contribution was found for social support and effectiveness of supervision. The study identifies factors that can prevent distress among professionals such as child protection workers, who are exposed to the trauma of child abuse victims. Recommendations are provided accordingly. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Protecting Touch: Authenticated App-To-Server Channels for Mobile Devices Using NFC Tags

    Directory of Open Access Journals (Sweden)

    Fernando Kaway Carvalho Ota

    2017-07-01

    Full Text Available Traditional authentication methods (e.g., password, PIN often do not scale well to the context of mobile devices in terms of security and usability. However, the adoption of Near Field Communication (NFC on a broad range of smartphones enables the use of NFC-enabled tokens as an additional authentication factor. This additional factor can help to improve the security, as well as usability of mobile apps. In this paper, we evaluate the use of different types of existing NFC tags as tokens for establishing authenticated secure sessions between smartphone apps and web services. Based on this evaluation, we present two concepts for a user-friendly secure authentication mechanism for mobile apps, the Protecting Touch (PT architectures. These two architectures are designed to be implemented with either end of the spectrum of inexpensive and widely-available NFC tags while maintaining a reasonable trade-off between security, availability and cost.

  19. UAuth: A Strong Authentication Method from Personal Devices to Multi-accounts

    Directory of Open Access Journals (Sweden)

    Yazhe Wang

    2015-10-01

    Full Text Available In this paper we present UAuth, a two-layer authentication framework that provides more security assurances than two-factor authentication while offering a simpler authentication experience. When authenticating, users first verified their static credentials (such as password, fingerprint, etc. on their devices to achieve the local-layer authentication, then submit the OTP-signed response generated by their device to the server to complete the server-layer authentication. We also propose the three-level account association mechanism, which establishes the association among devices, users and services, and then creates a mapping from user’s devices to user’s accounts. Users can gain access to different service via any device in the association easily. Our goal is to provide a quick and convenient SSO-like login process on the basis of security authentication. To meet the goal, we implement our UAuth, and evaluate our designs.

  20. Promises of protection? Article 16 of the Convention on the Rights of Persons with Disabilities and gender-based violence in South Africa.

    Science.gov (United States)

    Combrinck, Helene

    Article 16 of the Convention on the Rights of Persons with Disabilities (CRPD) guarantees persons with disabilities freedom from exploitation, violence and abuse. This article explores the current status of implementation of article 16 in South Africa, with specific reference to the legislative framework underpinning protection from exploitation, violence and abuse. This investigation is done specifically in the context of gender-based violence, which remains a cause of great concern in this country. Copyright © 2017. Published by Elsevier Ltd.

  1. Everyday Cyborgs: On Integrated Persons and Integrated Goods.

    Science.gov (United States)

    Quigley, Muireann; Ayihongbe, Semande

    2018-05-01

    Using the metaphor and actuality of the 'everyday cyborg', this article makes the case that the law is ill-equipped to deal with challenges raised by the linking of the organic, biological person with synthetic, inorganic parts and devices. For instance, should internal medical devices that keep the person alive be viewed as part of the person or mere objects (or something else)? Is damage to neuro-prostheses (eg nervous system integrated limb prostheses) personal injury or damage to property? Who ought to control/own the software in implanted medical devices? And how should the law deal with risks around third-party device access (including that of unauthorised access and hacking)? We argue that satisfactorily answering such questions will likely require a re-analysis of the conceptual and philosophical underpinnings of the law, as well as the law itself. To demonstrate this, we examine the uncharted terrain which everyday cyborgs pose for the law, looking in particular at five areas: (i) medical device regulation, safety, and product liability; (ii) damage to devices and liability; (iii) data and privacy; (iv) security and biohacking; and (v) intellectual property rights. The article highlights how advancing biotechnology continues to reveal, and prompts us to confront, lacunae within the law. Our analysis calls particular attention to law's boundary-work (how the law utilises and incorporates supposed ontological and moral boundaries) and the challenges which everyday cyborgs pose to this.

  2. Personal monitoring services available at Institute for Radiation Protection of ENEA

    International Nuclear Information System (INIS)

    Fantuzzi, E.; Bonarelli, T.

    1999-01-01

    Personnel monitoring provides the means to measure and record the radiation doses received by individual workers. The ionising radiation decree (230/95) set out the circumstances when the assessment and recording of person's exposure is legally required. Many employers issue dosemeters to staff even though there is no legal requirement to do so. This may be part of a quality assurance programme or as a reassurance measure. Dosemeter readings will serve to ensure compliance with legal dose limits and assure the employer that radiation exposure is as low as reasonably achievable. The ENEA (National Agency for New Technology, Energy and the Environment) IRP (Institute for Radiation Protection) individual monitoring service has been running for over 30 years. It offers personnel dosemeters which are based on its expertise and backed up by continual research and development. The report provides details of the dosemeters in use at IRP enable to decide which ones most suit the needs and shows IMS's organisation, customer and communications, dose reports form and administrative items. A short mention of future development will also be given [it

  3. Relay protection features of frequency-adjustable electric drive

    Science.gov (United States)

    Kuprienko, V. V.

    2018-03-01

    The features of relay protection of high-voltage electric motors in composition of the frequency-adjustable electric drive are considered in the article. The influence of frequency converters on the stability of the operation of various types of relay protection used on electric motors is noted. Variants of circuits for connecting relay protection devices are suggested. The need to develop special relay protection devices for a frequency-adjustable electric drive is substantiated.

  4. Üniversite Kütüphanelerinde Kişisel Verilerin Korunması=Protection of Personal Data in University Libraries

    Directory of Open Access Journals (Sweden)

    Türkay Henkoğlu

    2015-05-01

    Full Text Available Güvenilir bilgiye erişim ve büyük ölçüde elektronik ortamda saklanan mevcut bilginin korunmasına yönelik ihtiyaçların arttığı günümüzde, korunacak bilgi varlıkları içinde kişisel veriler önemli bir yer tutmaktadır. Bu bilgi varlıklarının korunması hukuksal, teknik ve idari boyutların dikkate alındığı bilgi güvenliği politikalarının gücü ile mümkün olabilmektedir. Bu çalışmada, kişisel verilerin korunmasına ilişkin temel ilkeler ve hukuksal düzenlemeler çerçevesinde üniversite kütüphanelerindeki mevcut durum değerlendirilerek, eksikliklerin giderilmesine yönelik önerilerde bulunulmuş ve bilgi güvenliği kültürünün oluşmasına katkı sağlanması hedeflenmiştir. Bu amaçla Ankara’da bulunan 15 üniversite kütüphanesini kapsayacak şekilde görüşme yoluyla anket uygulanmış ve alınan bilgi güvenliği önlemleri mevcut hukuksal düzenlemeler çerçevesinde değerlendirilmiştir. Çalışma sonucunda; yasal düzenlemelerin yeterli ve önleyici nitelikte olmadığı, üniversitelerde kişisel verilerin korunmasına ve verilerin güvenli olarak imha edilmesine ilişkin politikaların bulunmadığı, risk yönetiminin yapılmadığı, üniversite birimleri arasında sorumlulukların paylaşılmadığı, kişisel verileri işleyen personele veri korumaya ilişkin bilinçlendirme eğitimi verilmediği ve kişisel verileri işleyen birimlerin hangi verilerin kişisel veri olduğu konusunda dahi tereddütlerinin bulunduğu görülmektedir./Today, with the significant increase in the need for the access to reliable information andfor the protection of available information stored electronically; personal data has becomeone of the most important information assets that must be protected. The protection of theseinformation assets is only possible with the power of information security policies including legal,technical, and administrative dimensions. In this study, current situation of

  5. Improved Short-Circuit Protection for Power Cells in Series

    Science.gov (United States)

    Davies, Francis

    2008-01-01

    A scheme for protection against short circuits has been devised for series strings of lithium electrochemical cells that contain built-in short-circuit protection devices, which go into a high-resistance, current-limiting state when heated by excessive current. If cells are simply connected in a long series string to obtain a high voltage and a short circuit occurs, whichever short-circuit protection device trips first is exposed to nearly the full string voltage, which, typically, is large enough to damage the device. Depending on the specific cell design, the damage can defeat the protective function, cause a dangerous internal short circuit in the affected cell, and/or cascade to other cells. In the present scheme, reverse diodes rated at a suitably high current are connected across short series sub-strings, the lengths of which are chosen so that when a short-circuit protection device is tripped, the voltage across it does not exceed its rated voltage. This scheme preserves the resetting properties of the protective devices. It provides for bypassing of cells that fail open and limits cell reversal, though not as well as does the more-expensive scheme of connecting a diode across every cell.

  6. Electronic personal dosemeters

    International Nuclear Information System (INIS)

    Marshall, T.O.; Bartlett, D.T.; Burgess, P.H.; Cranston, C.S.; Higginbottom, D.J.; Sutton, K.W.

    1990-01-01

    Personal dosimetry services approved by their national authorities for category A workers, invariably use passive dosemeters incorporating photographic film or thermoluminescent detectors. However, the performance characteristics of electronic dosemeters has improved substantially over the past decade to such an extent that in the opening lecture of the Solid State Dosimetry Conference at Oxford in 1986 the development of an electronic 'smart card' based on a silicon detector was briefly discussed. This idea has been taken up and at least one development programme is in progress aimed at the production of an electronic dosemeter suitable for use as a legal device. The more important performance requirements of personal dosemeters for this purpose are discussed and the earlier electronic dosemeter designs and the latest devices under development to meet this specification are compared. (author)

  7. Modern Electronic Devices: An Increasingly Common Cause of Skin Disorders in Consumers.

    Science.gov (United States)

    Corazza, Monica; Minghetti, Sara; Bertoldi, Alberto Maria; Martina, Emanuela; Virgili, Annarosa; Borghi, Alessandro

    2016-01-01

    : The modern conveniences and enjoyment brought about by electronic devices bring with them some health concerns. In particular, personal electronic devices are responsible for rising cases of several skin disorders, including pressure, friction, contact dermatitis, and other physical dermatitis. The universal use of such devices, either for work or recreational purposes, will probably increase the occurrence of polymorphous skin manifestations over time. It is important for clinicians to consider electronics as potential sources of dermatological ailments, for proper patient management. We performed a literature review on skin disorders associated with the personal use of modern technology, including personal computers and laptops, personal computer accessories, mobile phones, tablets, video games, and consoles.

  8. DeviceGuard: External Device-Assisted System And Data Security

    OpenAIRE

    Deng, Yipan

    2011-01-01

    This thesis addresses the threat that personal computer faced from malware when the personal computer is connected to the Internet. Traditional host-based security approaches, such as anti-virus scanning protect the host from virus, worms, Trojans and other malwares. One of the issues of the host-based security approaches is that when the operating system is compromised by the malware, the antivirus software also becomes vulnerable. In this thesis, we present a novel approach through usin...

  9. ETHIOPIAN WITNESS PROTECTION SYSTEM: COMPARATIVE ...

    African Journals Online (AJOL)

    witness protection involves social cohesion of the protected person. Scholars ..... interests' need to balance an accused right to know and confront prosecution ..... was reduced to 2.5 years through the fast tracking of witness protection cases.

  10. Embassies and Personal Data

    DEFF Research Database (Denmark)

    Blume, Peter Erik

    2011-01-01

    The article considers how data protection rules in Directive 95/46 EC and in national law apply to data processing carried out by an embassy. Three situations are discussed: processing inside and from the embassy, processing in the recieving country on behalf of an embassy, and transference...... of personal data from the embassy to the home country. Although an embassy may represent an unsafe area for the personal integrity of citizens, this topic has not been considered in data protection law and for this reason there are no references ind the article....

  11. Improving Accessibility to Medical Services for Persons with Disabilities in Thailand

    Directory of Open Access Journals (Sweden)

    Anpatcha Sakhornkhan

    2012-06-01

    Full Text Available Purpose: This action research aimed at developing an action plan to improve the accessibility to home health care and assistive devices for persons with disabilities in a rural community, and to evaluate changes in the numbers of such persons who received appropriate home health care and assistive devices after a three-month implementation of the action plan.Method: The study was conducted at a sub-district of Maha Sarakham Province, Thailand. The main beneficiaries were 99 persons with disabilities (mean age55.4±18.7 years. Group meetings were organised for persons with disabilities, caregivers, and various community members. An action plan for improving the accessibility of persons with disabilities to home health care and assistive devices was collaboratively formulated and implemented for three months.Results: The main strategy for improving accessibility was to increase the competency of village health volunteers in providing home health care and assistive devices to persons with disabilities. After the three-month action plan implementation, the number of persons with disabilities who received appropriate home health care, i.e. at least once a month, significantly increased from 33.3% to 72.2% (Chi-square test, PConclusions: Under the supervision of physical therapists and/or other allied health professionals, the village health volunteer is likely to be a key person for improving the accessibility to home health care and assistive devices for persons with disabilities in a rural community.Limitations: The study was limited to only one sub-district. No comparable areas were studied. Further, since the study recruited persons with disabilities from a rural community, applicability of the findings to persons with disabilities in an urban community should be considered judiciously.

  12. Development of personal dose monitoring system using wireless data transmission device

    International Nuclear Information System (INIS)

    Inui, Daisuke; Nakashima, Sadao

    2008-01-01

    Radiation workers working in radiation controlled area in nuclear power plants etc., are required to carry a dosimeters by regulation law. The workers are controlled daily on personal exposure dose by reading out the exposure dose information of the dosimeters with an area access control gate installed at the entrance of the radiation controlled area. This type of personal dose monitoring system has a problem that each worker can get his personal dose data only at the entrance of the radiation controlled area several times a day. We developed a system to get the real-time acquisition of personal dose data especially for workers working in a high dose area. This system is generally composed of a dosimeter with a wireless attachment, relay station, and monitor. Some relay stations set in main work places in the radiation controlled area can collect real-time personal dose data of each dosimeter carried by workers at the work place with the relay stations, and transmit it to the monitor to get personal dose data of individual workers. A wireless communication system between dosimeters and relay stations is applied to collect efficiently all personal dose data in the work place. (author)

  13. Selecting the Protective Ear Plugs

    OpenAIRE

    Manouchehr Omidvari

    1999-01-01

    Exposure to noise is a one of the common problems in any industrial places. Many solutions have been introduced to overcome the deleterious effects of noise pollution maintaining and repairing systems in the equipments, environmental control and hearing conservation systems are some of these solutions that could be mentioned. "nThere are various types of Hearing protection devices and each one is useful under special circumstances. Commonly, different Hearing protection devices have a particu...

  14. 23081 - Royal Decree No. 1132 of 14 September 1990 laying down basic measures for radiation protection of persons undergoing medical examination or treatment

    International Nuclear Information System (INIS)

    1990-01-01

    This Royal Decree incorporates into Spanish regulations Directive 84/466 Euratom which lays down basic measures for the radiation protection of persons undergoing medical examination or treatment. Any exposure to radiation for medical purposes must be medically justified and be conducted under the responsibility of a medical or dental practitioner adequately trained in the radiation protection field. All relevant facilities must be recorded in the national inventories to avoid unnecessary proliferation of such equipment [fr

  15. Innovating transformative medical devices and growing the local medical device manufacturing sector

    CSIR Research Space (South Africa)

    Bunn, Tony

    2017-01-01

    Full Text Available . The 4IR is marked by emerging technology breakthroughs in a number of fields, including robotics, genomics, biosensors and wearables, AI, the internet of things, quantum computing, big data predictive analytics, 3D printing/additive manufacturing... of personalized prosthetics and products • Personalized devices and technologies for precision medicine Secure Airway Clamp for safer Anaesthesia MANDIBULAR IMPLANTS PATIENT 2 PATIENT 1 PATIENT 3 PATIENT CT SCAN 3D PRINTED TITANIUM IMPLANT PROPOSED...

  16. Protection of the LHC against Unsynchronised Beam Aborts

    CERN Document Server

    Goddard, B; Carlier, E; Uythoven, J; Wenninger, J; Weterings, W

    2006-01-01

    An unsynchronised beam abort in the LHC could damage downstream accelerator components, in particular the extraction septum magnets, the experimental low-beta triplet magnet apertures and the tertiary collimators. Although the LHC beam dumping system includes design features to minimise their frequency, such unsynchronised aborts cannot be excluded. A system of protection devices comprising fixed and moveable diluters and collimators will protect the downstream LHC aperture from the misdirected bunches in case of such a failure. The sources of unsynchronised aborts are described, together with the requirements and design of the protection devices and their expected performance. The accompanying operational requirements and envisaged solutions are discussed, in particular the problem of ensuring the local orbit at the protection devices.

  17. Physical Protection of Nuclear Safeguards Technology

    International Nuclear Information System (INIS)

    Hoskins, Richard

    2004-01-01

    IAEA's Nuclear Security Plan is established to assist Member States in implementing effective measures against nuclear terrorism. Four potential threats were identified: theft of nuclear weapon, nuclear explosive device, radiological dispersal device and an attack on radiation facility. In order to achieve effective protection of nuclear materials and facilities, the IAEA sponsored the Convention of the Physical Protection of Nuclear Materials which focuses on the protection of nuclear materials 'in international transport. The IAEA also promoted INFCIRC/255 entitled the Physical Protection of Nuclear Materials and Nuclear Facilities and published TECDOC/967 for the protection of nuclear materials and facilities against theft and sabotage and during transport. Assistance is available for the Member States through the International Physical Protection Advisory Service (IPPAS) and the International Nuclear Security Advisory Service (INSServ). (author)

  18. Components for containment enclosures. Part 4: Ventilation and gas-cleaning systems such as filters, traps, safety and regulation valves, control and protection devices

    International Nuclear Information System (INIS)

    2001-01-01

    ISO 11933 consists of the following parts, under the general title Components for containment enclosures: Part 1: Glove/bag ports, bungs for glove/bag ports, enclosure rings and interchangeable units; Part 2: Gloves, welded bags, gaiters for remote-handling tongs and for manipulators; Part 3: Transfer systems such as plain doors, airlock chambers, double door transfer systems, leaktight connections for waste drums; Part 4: Ventilation and gas-cleaning systems such as filters, traps, safety and regulation valves, control and protection devices; Part 5: Penetrations for electrical and fluid circuits. This part of ISO 11933 specifies the design criteria and the characteristics of various components used for ventilation and gas-cleaning in containment enclosures. These components are either directly fixed to the containment enclosure wall, or used in the environment of a shielded or unshielded containment enclosure or line of such enclosures. They can be used alone or in conjunction with other mechanical components, including those specified in ISO 11933-1 and ISO 11933-3. This part of ISO 11933 is applicable to: filtering devices, including high-efficiency particulate air (HEPA) filters and iodine traps; safety valves and pressure regulators; systems ensuring the mechanical protection of containment enclosures; control and pressure-measurement devices

  19. Protecting computer-based medical devices: defending against viruses and other threats.

    Science.gov (United States)

    2005-07-01

    The increasing integration of computer hardware has exposed medical devices to greater risks than ever before. More and more devices rely on commercial off-the-shelf software and operating systems, which are vulnerable to the increasing proliferation of viruses and other malicious programs that target computers. Therefore, it is necessary for hospitals to take steps such as those outlined in this article to ensure that their computer-based devices are made safe and continue to remain safe in the future. Maintaining the security of medical devices requires planning, careful execution, and a commitment of resources. A team should be created to develop a process for surveying the security status of all computerized devices in the hospital and making sure that patches and other updates are applied as needed. These patches and updates should be approved by the medical system supplier before being implemented. The team should consider using virtual local area networks to isolate susceptible devices on the hospital's network. All security measures should be carefully documented, and the documentation should be kept up-to-date. Above all, care must be taken to ensure that medical device security involves a collaborative, supportive partnership between the hospital's information technology staff and biomedical engineering personnel.

  20. Overview of Robotic Devices for Nursing Care Project.

    Science.gov (United States)

    Hirukawa, Hirohisa

    2017-01-01

    METI/AMED are conducting a project on the development and deployment of robotic devices for nursing care to enhance the autonomy of elderly persons and assist care givers. An evaluation protocol is presented and the devices developed in the project are introduced. The devices consist of transfer assist devices (wearable/non-wearable), walking assist devices (outdoor/indoor), safety surveillance sensors (nursing home/private home), bath lift and toilet assist.

  1. Mallow Fiber-Reinforced Epoxy Composites in Multilayered Armor for Personal Ballistic Protection

    Science.gov (United States)

    Nascimento, Lucio Fábio Cassiano; Louro, Luis Henrique Leme; Monteiro, Sergio Neves; Lima, Édio Pereira; da Luz, Fernanda Santos

    2017-10-01

    Lighter and less expensive polymer composites reinforced with natural fibers have been investigated as possible components of a multilayered armor system (MAS) for personal protection against high-velocity ammunition. Their ballistic performance was consistently found comparable with that of conventional Kevlar® synthetic aramid fiber. Among the numerous existing natural fibers with the potential for reinforcing polymer composites to replace Kevlar® in MAS, mallow fiber has not been fully investigated. Thus, the objective of this work is to evaluate the ballistic performance of epoxy composites reinforced with 30 vol.% of aligned mallow fibers as a second MAS layer backing a front ceramic plate. The results using high-velocity 7.62 ammunition show a similar indentation to a Kevlar® layer with the same thickness. An impedance matching calculation supports the similar ballistic performance of mallow fiber composite and Kevlar®. Reduced MAS costs associated with the mallow fiber composite are practical advantages over Kevlar®.

  2. Protection coordination of the Kennedy Space Center electric distribution network

    Science.gov (United States)

    1976-01-01

    A computer technique is described for visualizing the coordination and protection of any existing system of devices and settings by plotting the tripping characteristics of the involved devices on a common basis. The program determines the optimum settings of a given set of protective devices and configuration in the sense of the best expected coordinated operation of these devices. Subroutines are given for simulating time versus current characteristics of the different relays, circuit breakers, and fuses in the system; coordination index computation; protection checks; plotting; and coordination optimation.

  3. Safety of mechanical devices. Safety of automation systems

    International Nuclear Information System (INIS)

    Pahl, G.; Schweizer, G.; Kapp, K.

    1985-01-01

    The paper deals with the classic procedures of safety engineering in the sectors mechanical engineering, electrical and energy engineering, construction and transport, medicine technology and process technology. Particular stress is laid on the safety of automation systems, control technology, protection of mechanical devices, reactor safety, mechanical constructions, transport systems, railway signalling devices, road traffic and protection at work in chemical plans. (DG) [de

  4. Performance test of personal RF monitor for area monitoring at magnetic confinement fusion facility

    International Nuclear Information System (INIS)

    Tanaka, M.; Uda, T.; Wang, J.; Fujiwara, O.

    2012-01-01

    For safety management at a magnetic confinement fusion-test facility, protection from not only ionising radiation, but also non-ionising radiation such as the leakage of static magnetic and electromagnetic fields is an important issue. Accordingly, the use of a commercially available personal RF monitor for multipoint area monitoring is proposed. In this study, the performance of both fast- and slow-type personal RF monitors was investigated by using a transverse electromagnetic cell system. The range of target frequencies was between 10 and 300 MHz, corresponding to the ion cyclotron range of frequency in a fusion device. The personal RF monitor was found to have good linearity, frequency dependence and isotropic response. However, the time constant for the electric field sensor of the slow-type monitor was much longer than that for the fast-type monitor. Considering the time-varying field at the facility, it is found that the fast-type monitor is suitable for multipoint monitoring at magnetic confinement fusion test facilities. (authors)

  5. Inventing urine incontinence devices for women.

    Science.gov (United States)

    Pieper, B; Cleland, V; Johnson, D E; O'Reilly, J L

    1989-01-01

    Nurses have long been aware of the devastating effects of urinary incontinence on women. Although women may find diapers, pads and protective clothing valuable protection, there are few options for a continuous wear, external urine incontinence device (EUID). Inventors have attempted to develop an EUID since ancient times; the first United States patent for an EUID was awarded in 1949. The purpose of this paper is to review technological considerations for development of an external urinary incontinence device for women. Patents and products illustrate the considerations.

  6. Personal protection accessories (PPA) as a primary health safety measures in pesticide use

    International Nuclear Information System (INIS)

    Aslam, M.; Akhtar, A.; Kanwal, S.; Ali, T.; Zafar, M.I.

    2008-01-01

    Fruit growers from three districts of the Punjab took part in this study whereas their knowledge, attitude, skill and practices were evaluated regarding the use of pesticides. The hygiene and sanitation practices of the respondents were also related with proper use of PPA during pesticide spray which needs attitudinal changes along with the provision of better facilities and infrastructure. Demographic features of the fruit growers were evaluated regarding their age, qualification, marital status, source of income, smoking habits, farming size, fruit production and pesticide spraying experience. The ordinal regression model determined the significant relation among the qualification, spraying experience and land holding size with their level of knowledge and skill of using personal protection accessories (PPA). It is recommended that pesticide safety education and better skill be given to pesticide sprayers for the appropriate use of PPA. (author)

  7. Based on Civil Law Perspective of Study on the Legal Problems of the Protection of Personal Information%民法角度下个人信息保护的相关问题探讨

    Institute of Scientific and Technical Information of China (English)

    李宁; 贾茜

    2017-01-01

    With the rapid development of society,in recent years,people's personal information has been illegally collected for illegal channels,personal information is no longer used to steal the use of more and more.However,there is no definite legal provision in the existing legal provisions of personal information,and the existence of its legal system is almost blank,leading to more and more information theft cases.For China's current personal information protection issues,a variety of civil law scholars say that the reason,or because of the current law of China's lack of civil law and the relevant departments of the supervision of dereliction of duty.Leading to the protection of the current personal information in China is facing a grim situation.To clarify the current legal provisions of the protection of personal information,it is necessary to personal information on the rule of law attributes of the analysis of personal information that the privacy rights and other issues.But the personal information is still in a framework of the concept of rights,it must be explained for the concept,it is more conducive to the legal positioning of personal information protection,to achieve the protection of personal information rights and interests,so as to effectively achieve the personal information of the property theory to protect the continuation The Through the elaboration of the theoretical development and the present situation of the personal information right,this article analyzes the dilemma faced by the current personal information protection in our country,so as to explore the way to effectively protect the personal information.%随着社会的飞速发展,近年来,人们的个人信息被非法采集用于非法途径,个人信息无端被盗窃使用的行为越来越多.但是我国目前对于个人信息没有确切的法律规定,其法律制度的存在作用

  8. Protection of persons undergoing radiological examinations ...

    African Journals Online (AJOL)

    Protection was in the form of gonad shields, lead apron to shield the unwanted parts during examinations and coning the X-ray field before exposure. The staff had Thermoluminscent Dosimeters (TLD) to monitor dose levels received by such staff every three months. They wore hand gloves, lead aprons and stayed behind ...

  9. High energy overcurrent protective device

    Science.gov (United States)

    Praeg, Walter F.

    1982-01-01

    Electrical loads connected to capacitance elements in high voltage direct current systems are protected from damage by capacitance discharge overcurrents by connecting between the capacitance element and the load, a longitudinal inductor comprising a bifilar winding wound about a magnetic core, which forms an incomplete magnetic circuit. A diode is connected across a portion of the bifilar winding which conducts a unidirectional current only. Energy discharged from the capacitance element is stored in the inductor and then dissipated in an L-R circuit including the diode and the coil winding. Multiple high voltage circuits having capacitance elements may be connected to loads through bifilar windings all wound about the aforementioned magnetic core.

  10. Correlations between self-handicapping and self-defeating personality.

    Science.gov (United States)

    Schill, T; Morales, J; Beyler, J; Tatter, T; Swigert, L

    1991-10-01

    In this study scores on Strube's self-handicapping scale were correlated with scores on Schill's self-defeating personality scale. Berglas believes there are subtypes of self-defeating personality and that his concept of self-handicapping should be correlated with the three criteria which represent a self-protective component of self-defeating personality. Some support for Berglas' proposition was found, particularly for men. However, correlations with other components of self-defeating personality suggest the criteria thought to be self-protective may need to be reconsidered.

  11. A Security Architecture for Personal Networks

    NARCIS (Netherlands)

    Jehangir, A.

    2009-01-01

    The proliferation of personal mobile computing devices such as laptops and mo- bile phones, as well as wearable computing devices such as belt computers, digital bracelets and bio-medical sensors has created an opportunity to create a wireless network to share information and resources amongst

  12. Process and device for energy production from thermonuclear fusion reactions

    International Nuclear Information System (INIS)

    Bussard, R.W.; Coppi, Bruno.

    1977-01-01

    An energy generating system is described using a fusion reaction. It includes several contrivances for confining a plasma in an area, a protective device around a significant part of each of these confinement contrivances, an appliance for introducing a fusion reaction fuel in each of the confinements so that the plasma may be formed. Each confinement can be separated from the protective device so that it may be replaced by another. The system is connected to the confinements, to the protective devices or to both. It enables the thermal energy to be extracted and transformed into another form, electric, mechanical or both [fr

  13. Ionizing secondary radiation generated by analog radiological and digital coronary cine angiographic equipment. Influence of external protection devices

    International Nuclear Information System (INIS)

    Ramirez N, Alfredo; Farias Ch, Eric; Silva J, Ana Maria; Leyton L, Fernando; Oyarzun C, Carlos; Ugalde P, Hector; Dussaillant, Gaston; Cumsille G, Angel

    2000-01-01

    Exposure to ionizing radiation is a know hazard of radiological procedures. Aim: to compare the emission of secondary ionizing radiation from two coronary angiographic equipments, one with digital and the other with analog image generation. To evaluate the effectiveness of external radiological protection devices. Material and methods: environmental and fluoroscopy generated radiation in the cephalic region of the patient was measured during diagnostic coronary angiographies. Ionizing radiation generated in anterior left oblique protection (ALO) and anterior right oblique protection (ARO) were measured with and without leaded protections. In 19 patients (group 1), a digital equipment was used and in 21 (group 2), an analog equipment. Results: header radiation for group 1 and 2 was 1194±337 and 364±222 μGray/h respectively (p≤0.001). During fluoroscopy and with leaded protection generated radiation for groups 1 and 2 was 612±947 and 70±61μGray/h respectively (p≤0.001). For ALO projection, generated for groups 1 and 2 was 105±47 and 71±192 μGray/h respectively (p≤0.001). During filming the radiation for ALO projection for groups 1 and 2 was 7252±9569 and 1671±2038 μGray/h respectively (p=0.03). Out of the protection zone, registered radiation during fluoroscopy for groups 1 and 2 was 2800±1741 and 1318±954 μGray/h respectively (p≤0.001); during filming, the figures were 15500±5840 and 18961±10599 μGray/h respectively (NS). Conclusions: digital radiological equipment has a lower level of ionizing radiation emission than the analog equipment

  14. Mobile Learning Devices. Essentials for Principals

    Science.gov (United States)

    Rogers, Kipp D.

    2011-01-01

    In "Mobile Learning Devices," the author helps educators confront and overcome their fears and doubts about using mobile learning devices (MLDs) such as cell phones, personal digital assistants, MP3 players, handheld games, digital audio players, and laptops in classrooms. School policies that ban such tools are outdated, the author suggests;…

  15. 40 CFR 152.500 - Requirements for devices.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Requirements for devices. 152.500 Section 152.500 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS... other than a bacterium, virus, or other microorganism on or in living man or living animals) but not...

  16. Personal power systems

    Energy Technology Data Exchange (ETDEWEB)

    Dunn-Rankin, Derek; Leal, Elisangela Martins; Walther, David C. [Mechanical and Aerospace Engineering Department, University of California, Irvine, CA 92697 (United States)

    2005-07-01

    The lack of compact, efficient, human compatible, lightweight power sources impedes the realization of machine-enhanced human endeavor. Electronic and communication devices, as well as mobile robotic devices, need new power sources that will allow them to operate autonomously for periods of hours. In this work, a personal power system implies an application of interest to an individual person. The human-compatible gravimetric energy density spans the range from 500 to 5000Wh/kg, with gravimetric power density requirements from 10 to 1000W/kg. These requirements are the primary goals for the systems presented here. The review examines the interesting and promising concepts in electrochemical, thermochemical, and biochemical approaches to small-scale power, as well as their technological and physical challenges and limitations. Often it is the limitations that dominate, so that while the technology to create personal autonomy for communications, information processing and mobility has accelerated, similar breakthroughs for the systems powering these devices have not yet occurred. Fuel cells, model airplane engines, and hummingbird metabolism, are three promising examples, respectively, of electrochemical, thermochemical, and biochemical power production strategies that are close to achieving personal power systems' power demands. Fuel cells show great promise as an energy source when relatively low power density is demanded, but they cannot yet deliver high peak powers nor respond quickly to variable loads. Current small-scale engines, while achieving extraordinary power densities, are too inefficient to achieve the energy density needed for long-duration autonomous operation. Metabolic processes of flying insects and hummingbirds are remarkable biological energy converters, but duplicating, accelerating, and harnessing such power for mobility applications is virtually unexplored. These challenges are significant, and they provide a fertile environment for

  17. 46 CFR 111.50-5 - Location of overcurrent protective devices.

    Science.gov (United States)

    2010-10-01

    ... Section 111.50-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Overcurrent Protection § 111.50-5 Location of overcurrent protective... primary side of a single phase transformer (two wire with single-voltage secondary) also protects the...

  18. The role of personal protective factors in anchoring psychological ...

    African Journals Online (AJOL)

    In this article I report on a study that focused on the concept of resilience, in order to determine the nature of personal attributes in adolescents with learning difficulties, who were able to rebound from life's onslaughts, and to continue determinedly along the path of self-actualisation. The personal attributes impacting on the ...

  19. Special Article Personal Wearable Technologies in Education: Value or Villain?

    Science.gov (United States)

    Borthwick, Arlene C.; Anderson, Cindy L.; Finsness, Elizabeth S.; Foulger, Teresa S.

    2015-01-01

    Wearable personal learning technologies can gather data from the person wearing the device or from the surrounding environment and enable that data to be transferred to another device or shared via the cloud. Wearable technologies can serve as a valuable asset in the classroom enhancing differentiation of instruction and student engagement. They…

  20. Control rod blow out protection system

    International Nuclear Information System (INIS)

    Dietrich, J.R.; Flinn, W.S.; Groves, M.D.

    1979-01-01

    An absorber element blow-out protection system for a nuclear reactor having a pressure vessel through which a coolant is circulated. The blow-out protection system includes devices which hydraulically couple groups of guide tubes in which the absorber elements move, the coupling devices limiting coolant lift flow rate to a level commensurate with the raising of individual absorber elements but insufficient to raise a plurality of absorber elements simultaneously

  1. Major breakthrough in personal dust protection

    Energy Technology Data Exchange (ETDEWEB)

    Chadwick, J.

    2004-09-15

    With new studies highlighting one in every 20 miners developing 'black lung', USA labour, industry and government have joined forces to develop a solution. The rapid advance in Personal Dust Monitor (PDM) technology is a perfect example. The article reports a PDM, which is developed by the US National Institute for Occupational Safety and Health, working in the partnership with the United Mine Workers of America, the Bituminous Coal Operators Association and the National Mining Association.

  2. Mathematical and empirical proof of principle for an on-body personal lift augmentation device (PLAD).

    Science.gov (United States)

    Abdoli-Eramaki, Mohammad; Stevenson, Joan M; Reid, Susan A; Bryant, Timothy J

    2007-01-01

    In our laboratory, we have developed a prototype of a personal lift augmentation device (PLAD) that can be worn by workers during manual handling tasks involving lifting or lowering or static holding in symmetric and asymmetric postures. Our concept was to develop a human-speed on-body assistive device that would reduce the required lumbar moment by 20-30% without negative consequences on other joints or lifting kinematics. This paper provides mathematical proof using simplified free body diagrams and two-dimensional moment balance equations. Empirical proof is also provided based on lifting trials with nine male subjects who executed sagittal plane lifts using three lifting styles (stoop, squat, free) and three different loads (5, 15, and 25kg) under two conditions (PLAD, No-PLAD). Nine Fastrak sensors and six in-line strap force sensors were used to estimate the reduction of compressive and shear forces on L4/L5 as well as estimate the forces transferred to the shoulders and knees. Depending on lifting technique, the PLAD applied an added 23-36Nm of torque to assist the back muscles during lifting tasks. The peak pelvic girdle contact forces were estimated and their magnitudes ranged from 221.3+/-11.2N for stoop lifting, 324.3+/-17.2N for freestyle lifts to 468.47+/-23.2N for squat lifting. The PLAD was able to reduce the compression and shear forces about 23-29% and 7.9-8.5%, respectively.

  3. IAEA calls for enhanced radiation protection of patients. Safety specialists warn against overuse of new imaging devices

    International Nuclear Information System (INIS)

    2009-01-01

    Advances in medical imaging techniques are allowing doctors to detect hidden diseases and make ever more accurate diagnoses. But radiation safety experts at the International Atomic Energy Agency (IAEA) say that overuse of high-tech scanning procedures may unnecessarily expose patients to increased radiation levels. The IAEA, in collaboration with other international organizations, is developing a series of measures aimed at strengthening patient protection. The focus of recent efforts is a Smart Card project, to log how much radiation a person receives in the course of a lifetime. Concern surrounds procedures such as computed tomography (CT) scans because they deliver higher doses of radiation to patients in comparison to conventional X-rays (radiographs). It's been estimated that the average radiation dose of one CT scan is equal to roughly 500 chest X-rays. And that can increase a patient's lifetime risk of cancer, particularly if CT scans are repeated. The IAEA is one of the key international players in the field of patient radiation protection. A unit dedicated to the Radiological Protection of Patients (RPoP) was established in 2001. The IAEA's activities in radiation protection of patients include training, knowledge sharing and capacity building in the medical use of radiation. Extensive, up-to-date training material for health professionals is freely available on the RPoP website. An International Action Plan on the Radiological Protection of Patients that has been established together with leading international organizations such as the World Health Organization (WHO), UNSCEAR, the International Commission on Radiological Protection (ICRP) and others to identify strategies for strengthening radiation protection of patients. Coordinating and managing technical cooperation projects with Member States on patient dose assessment. The aim is to identify the factors that contribute to unnecessary radiation dose to patients, provide guidance on dealing with

  4. Micro processors for plant protection

    International Nuclear Information System (INIS)

    McAffer, N.T.C.

    1976-01-01

    Micro computers can be used satisfactorily in general protection duties with economic advantages over hardwired systems. The reliability of such protection functions can be enhanced by keeping the task performed by each protection micro processor simple and by avoiding such a task being dependent on others in any substantial way. This implies that vital work done for any task is kept within it and that any communications from it to outside or to it from outside are restricted to those for controlling data transfer. Also that the amount of this data should be the minimum consistent with satisfactory task execution. Technology is changing rapidly and devices may become obsolete and be supplanted by new ones before their theoretical reliability can be confirmed or otherwise by field service. This emphasises the need for users to pool device performance data so that effective reliability judgements can be made within the lifetime of the devices. (orig.) [de

  5. Selecting the Protective Ear Plugs

    Directory of Open Access Journals (Sweden)

    Manouchehr Omidvari

    1999-03-01

    Full Text Available Exposure to noise is a one of the common problems in any industrial places. Many solutions have been introduced to overcome the deleterious effects of noise pollution maintaining and repairing systems in the equipments, environmental control and hearing conservation systems are some of these solutions that could be mentioned. "nThere are various types of Hearing protection devices and each one is useful under special circumstances. Commonly, different Hearing protection devices have a particular brochure to introduce information about the manufacturers and the quality of noise reduction in that special production. "nThree different methods are commonly used to determine the noise reduction factor in various Hearing protection devices. All these methods have been presented based on the mathematical evaluations and according to the spectral features of the sound existing in the environment and then the sound pressure level is determined in dBA. In the current article we will have a look on the mentioned arithmetic models and their special characteristics.

  6. Recommending personally interested contents by text mining, filtering, and interfaces

    Science.gov (United States)

    Xu, Songhua

    2015-10-27

    A personalized content recommendation system includes a client interface device configured to monitor a user's information data stream. A collaborative filter remote from the client interface device generates automated predictions about the interests of the user. A database server stores personal behavioral profiles and user's preferences based on a plurality of monitored past behaviors and an output of the collaborative user personal interest inference engine. A programmed personal content recommendation server filters items in an incoming information stream with the personal behavioral profile and identifies only those items of the incoming information stream that substantially matches the personal behavioral profile. The identified personally relevant content is then recommended to the user following some priority that may consider the similarity between the personal interest matches, the context of the user information consumption behaviors that may be shown by the user's content consumption mode.

  7. Weibull aging models for the single protective channel unavailability analysis by the device of stages

    International Nuclear Information System (INIS)

    Nunes, M.E.C.; Noriega, H.C.; Melo, P.F.F.

    1997-01-01

    Among the features to take into account in the unavailability analysis of protective channels, there is one that plays a dominant role - that of considering the equipment aging. In this sense, the exponential failure model is not adequate, since some transition rates are no more constant. As a consequence, Markovian models cannot be used anymore. As an alternative, one may use the device of stages that allows for transforming a Non Markovian model into an equivalent Markovian one by insertion of a fictitious states set, called stages. For a given time-dependent transition rate, its failure density is analysed as to the best combination of exponential distributions and then the moments of the original distribution and those of the combination are matched to estimate the necessary parameters. In this paper, the aging of the protective channel is supposed to follow Weibull distributions. Typical means and variances for the times to failure are considered and combinations of stages are checked. Initial conditions features are discussed in connection with states that are fictitious and to check the validity of the developed models. Alternative solutions by the discretization of the failure rates are generated. The results obtained agree quite well. (author). 7 refs., 6 figs

  8. Intelligent textiles for personal protection and safety

    National Research Council Canada - National Science Library

    Jayaraman, Sundaresan; Kiekens, Paul; Grancaric, Ana Marija

    2006-01-01

    .... Each chapter in the book provides an in-depth assessment of one particular facet of this emerging discipline - from analysis of the threats and sensing technologies to ergonomics of protecting...

  9. 46 CFR 183.380 - Overcurrent protection.

    Science.gov (United States)

    2010-10-01

    ...) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.380 Overcurrent protection. (a) Overcurrent protection must be provided for each ungrounded conductor for the purpose of opening the electric..., ground detector light, or potential transformer, must be protected by an overcurrent device. (d...

  10. Multicriteria Analysis model for the comparison of different rockfalls protection devices

    Science.gov (United States)

    Mignelli, C.; Pomarico, S.; Peila, D.

    2012-04-01

    which provides a comparison of the considered options. The developed model takes into account five different aspects of the decision-making process (economic, environmental, design, transport and social aspects) that have been organized according the hierarchical framework of the AHP technique. The criteria that were identified in the analysis and their weights, in the decision-making process, have been discussed and determined by means of specific focus groups with technical experts in the geo-engineering field. Three different protection devices, usually used for rockfall protection (embankment, shelter topped by rockfall barrier and tunnel), are compared through the AHP method, in a specific "geo" environment to show the feasibility of the method. The application of the AHP technique, which was performed using the Expert Choice software, allowed the most relevant aspects of the decision-making process to be highlighted and showing how the proposed method can be a valuable tool for public administration. Furthermore, in order to test the robustness of the proposed model a sensitivity analysis was carried out. The research has an originality value since it focuses on a participative methodological approach thus making the decision process more traceable and reliable.

  11. Armored garment for protecting

    Science.gov (United States)

    Purvis, James W [Albuquerque, NM; Jones, II, Jack F.; Whinery, Larry D [Albuquerque, NM; Brazfield, Richard [Albuquerque, NM; Lawrie, Catherine [Tijeras, NM; Lawrie, David [Tijeras, NM; Preece, Dale S [Watkins, CO

    2009-08-11

    A lightweight, armored protective garment for protecting an arm or leg from blast superheated gases, blast overpressure shock, shrapnel, and spall from a explosive device, such as a Rocket Propelled Grenade (RPG) or a roadside Improvised Explosive Device (IED). The garment has a ballistic sleeve made of a ballistic fabric, such as an aramid fiber (e.g., KEVLAR.RTM.) cloth, that prevents thermal burns from the blast superheated gases, while providing some protection from fragments. Additionally, the garment has two or more rigid armor inserts that cover the upper and lower arm and protect against high-velocity projectiles, shrapnel and spall. The rigid inserts can be made of multiple plies of a carbon/epoxy composite laminate. The combination of 6 layers of KEVLAR.RTM. fabric and 28 plies of carbon/epoxy laminate inserts (with the inserts being sandwiched in-between the KEVLAR.RTM. layers), can meet the level IIIA fragmentation minimum V.sub.50 requirements for the US Interceptor Outer Tactical Vest.

  12. Upgrade of the CERN SPS Extraction Protection Elements TPS

    CERN Document Server

    Borburgh, Jan; Barnes, Michael; Baud, Cedric; Fraser, Matthew; Kain, Verena; Maciariello, Fausto; Steele, Genevieve; Velotti, Francesco

    2017-01-01

    In 2006 the protection devices upstream of the septa in both extraction channels of the CERN SPS to the LHC were installed. Since then, new beam parameters have been proposed for the SPS beam towards the LHC in the framework of the LIU project. The mechanical parameters and assumptions on which these protection devices presently have been based, need validation before the new upgraded versions can be designed and constructed. The paper describes the design assumptions for the present protection device and the testing program for the TPSG4 at HiRadMat to validate them. Finally the requirements and the options to upgrade both extraction protection elements in the SPS are described.

  13. Electrochemical device

    Science.gov (United States)

    Grimes, Patrick G.; Einstein, Harry; Bellows, Richard J.

    1988-01-12

    A tunnel protected electrochemical device features channels fluidically communicating between manifold, tunnels and cells. The channels are designed to provide the most efficient use of auxiliary power. The channels have a greater hydraulic pressure drop and electrical resistance than the manifold. This will provide a design with the optimum auxiliary energy requirements.

  14. Mobility and orientation aid for blind persons using artificial vision

    International Nuclear Information System (INIS)

    Costa, Gustavo; Gusberti, Adrian; Graffigna, Juan Pablo; Guzzo, MartIn; Nasisi, Oscar

    2007-01-01

    Blind or vision-impaired persons are limited in their normal life activities. Mobility and orientation of blind persons is an ever-present research subject because no total solution has yet been reached for these activities that pose certain risks for the affected persons. The current work presents the design and development of a device conceived on capturing environment information through stereoscopic vision. The images captured by a couple of video cameras are transferred and processed by configurable and sequential FPGA and DSP devices that issue action signals to a tactile feedback system. Optimal processing algorithms are implemented to perform this feedback in real time. The components selected permit portability; that is, to readily get used to wearing the device

  15. Mobility and orientation aid for blind persons using artificial vision

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Gustavo; Gusberti, Adrian; Graffigna, Juan Pablo; Guzzo, MartIn; Nasisi, Oscar [Facultad de Ingenieria, Universidad Nacional de San Juan, San Juan (Argentina)

    2007-11-15

    Blind or vision-impaired persons are limited in their normal life activities. Mobility and orientation of blind persons is an ever-present research subject because no total solution has yet been reached for these activities that pose certain risks for the affected persons. The current work presents the design and development of a device conceived on capturing environment information through stereoscopic vision. The images captured by a couple of video cameras are transferred and processed by configurable and sequential FPGA and DSP devices that issue action signals to a tactile feedback system. Optimal processing algorithms are implemented to perform this feedback in real time. The components selected permit portability; that is, to readily get used to wearing the device.

  16. Mobility and orientation aid for blind persons using artificial vision

    Science.gov (United States)

    Costa, Gustavo; Gusberti, Adrián; Graffigna, Juan Pablo; Guzzo, Martín; Nasisi, Oscar

    2007-11-01

    Blind or vision-impaired persons are limited in their normal life activities. Mobility and orientation of blind persons is an ever-present research subject because no total solution has yet been reached for these activities that pose certain risks for the affected persons. The current work presents the design and development of a device conceived on capturing environment information through stereoscopic vision. The images captured by a couple of video cameras are transferred and processed by configurable and sequential FPGA and DSP devices that issue action signals to a tactile feedback system. Optimal processing algorithms are implemented to perform this feedback in real time. The components selected permit portability; that is, to readily get used to wearing the device.

  17. Protecting Cryptographic Memory against Tampering Attack

    DEFF Research Database (Denmark)

    Mukherjee, Pratyay

    In this dissertation we investigate the question of protecting cryptographic devices from tampering attacks. Traditional theoretical analysis of cryptographic devices is based on black-box models which do not take into account the attacks on the implementations, known as physical attacks. In prac......In this dissertation we investigate the question of protecting cryptographic devices from tampering attacks. Traditional theoretical analysis of cryptographic devices is based on black-box models which do not take into account the attacks on the implementations, known as physical attacks....... In practice such attacks can be executed easily, e.g. by heating the device, as substantiated by numerous works in the past decade. Tampering attacks are a class of such physical attacks where the attacker can change the memory/computation, gains additional (non-black-box) knowledge by interacting...... with the faulty device and then tries to break the security. Prior works show that generically approaching such problem is notoriously difficult. So, in this dissertation we attempt to solve an easier question, known as memory-tampering, where the attacker is allowed tamper only with the memory of the device...

  18. Do New Mobile Devices in Enterprises Pose A Serious Security Threat?

    OpenAIRE

    Ali A Altalbe

    2013-01-01

    The purpose of this paper is to introduce a research proposal designed to explore the network securityissues concerning mobile devices protection. Many threats exist and they harm not only computers but handheld devices as well. The mobility of phones and their excessive use make them more vulnerable. The findings suggest a list of protections that can provide high level of security for new mobile devices.

  19. MODELING PROTECTIVE DEVICES FOR DISTRIBUTION SYSTEMS WITH DISTRIBUTED GENERATION USING AN EMTP-TYPE TOOL REPRESENTACIÓN EN EMTP DE DISPOSITIVOS DE PROTECCIÓN DE REDES DE DISTRIBUCIÓN CON GENERACIÓN DISTRIBUIDA

    Directory of Open Access Journals (Sweden)

    Juan A Martínez-Velasco

    2010-08-01

    Full Text Available This paper presents the main features of a library of modules for representation of protective devices of distribution networks with distributed generation (DG. The impact of distributed generation in a distribution network depends, among other aspects, on the design of the protection system and the coordination between the different protective devices. The presence of distributed generation changes the radial nature of distribution systems and affects the performance of the protection system. This document discusses the present protection practices for distribution systems and DG interties, describes the implementation of protective devices (circuit breakers, relays, reclosers, fuses, sectionalizers in an EMTP-type tool, and presents some simulation results whose main goal is to analyze the impact of synchronous machine-based embedded generators on the coordination between the different types of protective devices.Este artículo presenta las características principales de una librería de módulos desarrollada para representar dispositivos de protección de una red de distribución de energía eléctrica con generación distribuida (GD. El impacto de la generación distribuida depende, entre otros aspectos, del diseño del sistema de protección, y de la coordinación entre los diferentes dispositivos de protección. La presencia de unidades generadoras altera el flujo radial inherente a un sistema de distribución y afecta al comportamiento del sistema de protección. Este trabajo presenta una introducción de los sistemas de protección de las redes de distribución y de la interconexión de unidades generadoras, describe la implantación de dispositivos de protección (interruptores, relés, reenganchadores, fusibles, seccionalizadores en un programa tipo EMTP, y presenta algunos resultados obtenidos mediante simulación, cuyo principal objetivo es ilustrar el impacto que la generación distribuida basada en generadores síncronos puede

  20. Personal Protective Equipment Guide for Military Medical Treatment Facility Personnel Handling Casualties From Weapons of Mass Destruction and Terrorism Events

    Science.gov (United States)

    2003-08-01

    Ebola, and Marburg viruses may be particularly prone to aerosol nosocomial spread. Not all infected patients develop VHFs. 3. There must be...strict adherence to hand hygiene (Ref. 100): Health care workers should clean their hands prior to donning personal protective equipment for patient...good example of a nonstochastic effect of radiation (Ref. 103). Nosocomial infection Infection acquired in the hospital. Nucleocapsid In a