WorldWideScience

Sample records for personal monitoring film

  1. Measurement of the external doses at low and high exposures by Agfa personal monitoring film, FD-III-B badge

    International Nuclear Information System (INIS)

    Mihai, F.; Stochioiu, A.; Bercea, S.; Udup, E.; Tudor, I.

    2008-01-01

    Full text: A growing number of papers report occupational exposure monitoring by different dosemeter devices. Researches into improvement of the personal dosemeter systems are encouraged. Dose measurement and especially skin dose measurement, are therefore increasingly important. Methods and acceptable dosemeter are not clearly defined and differ from a dosimetry laboratory to other depending on their specifically work procedure and type of dosemeter utilized. Taking into account the characteristic of the work place (industry, research, medical application) dosemeter have to cover a large dose range. The dose assessment problems are manly in low doses range (under 0.2 mSv) and higher doses range. For example, typical for radiation oncology and nuclear accident dosimetry the dose ranges are on the order of 2-70 Gy and 0.1-5 Gy. This work presents the performance of the Agfa personal monitoring film, badge FD-III-B type used in the most of the occupational exposure monitoring from Romania. The FD-III-B dosimeter, manufactured in Romania, is used for monitoring personnel working in radioactive environment - the photodosimetric method is the one of the most reliable method presenting the advantage that the film may be considered as master probe over 30 year and may be utilized during litigation. The dosimeter contains metallic filters of Al, Cu, Pb with different thicknesses, a plastic filter and a open window. The badge FD-III-B is a class B dosimeter according to the dose range and an indices 3 dosimeter from energy range of the radiations in conformity with Romanian Standard in force. Film Agfa 'personal monitoring', tacked in this experiment, consists of a low speed film (D2) and a very sensitive film (D10) designed for recording X-ray, gamma and beta radiation over the doses range 0.1 mSv to 1 Sv. The experiments have been effectuated at different background optical density (base fog) of the films and at different sources of radiation: 13 :7Cs, 60 Co and 24 : 1 Am

  2. Intercomparison of personal radiation monitoring services in the Asia/Pacific region

    International Nuclear Information System (INIS)

    Young, J.G.; Hargrave, N.J.

    1994-01-01

    The Australian Radiation Laboratory conducted an international intercomparison of personal radiation monitoring services in the Asia/Pacific region during 1991. Twenty nine organizations from sixteen countries took part in the study, with the People's Republic of China having eleven participants. Dosemeters incorporating thermoluminescent phosphors and conventional film were submitted for evaluation. Both types were irradiated at normal incidence on a phantom with 137 Cs gamma rays, X rays and beta radiation from a 90 Sr/ 90 Y source. Participants were requested to assess their dosemeters in terms of the new operational quantities of the ICRU for personal radiation monitoring, in particular the personal dose equivalents H p (0.07) and H p (10). (author)

  3. Digital dosimetry and personal and environmental monitoring assembly

    International Nuclear Information System (INIS)

    Cerovac, Z.; Radalj, Z.; Prlic, I.; Cerovac, H.

    1996-01-01

    Film+TLD and film or TLD Dosimetry have a certain delay in dose reporting, since the reports on occupational doses are usually available to the users within 40 days after the actual exposure. This is particularly important when the dose is received within the short-time interval or when the radiation source has some technical failures. For this reason, the additional monitoring is recommendable. The common Dosimetry service in Croatia is well established and the data available shows that over 80% of occupationally exposed persons are working in medical facilities, mainly with x-ray sources. Dosimetry services in the country are providing three types of dosemeters, film dosemeter badge, film+TLD dosemeter badge or plane TLD badge. We have decided to introduce the palette of digital pocket dosemeters to be used at different workplaces occupationally exposed to ionizing radiation. After the first experience with the ALARA 1G digital dosemeter it came out that this type of ionizing radiation measuring device is suitable for the various non-occupational purposes. After some technical improvement and with some telecommunication electronics this device is usable as a point environmental measuring station. This means that the probe of the record any change in normal environmental radiation field, send the data to the central station and to raise alarm if necessary. That is why we have made a prototype for environmental monitoring able to be connected to any kind of telecommunication net. (author)

  4. Online Bridge Crack Monitoring with Smart Film

    Directory of Open Access Journals (Sweden)

    Benniu Zhang

    2013-01-01

    Full Text Available Smart film crack monitoring method, which can be used for detecting initiation, length, width, shape, location, and propagation of cracks on real bridges, is proposed. Firstly, the fabrication of the smart film is developed. Then the feasibility of the method is analyzed and verified by the mechanical sensing character of the smart film under the two conditions of normal strain and crack initiation. Meanwhile, the coupling interference between parallel enameled wires of the smart film is discussed, and then low-frequency detecting signal and the custom communication protocol are used to decrease interference. On this basis, crack monitoring system with smart film is designed, where the collected crack data is sent to the remote monitoring center and the cracks are simulated and recurred. Finally, the monitoring system is applied to six bridges, and the effects are discussed.

  5. The task of official personal monitoring in Germany using electronic dosimetry systems

    International Nuclear Information System (INIS)

    Huebner, Stephan; Wahl, Wolfgang; Busch, Frank; Martini, Ekkehard

    2008-01-01

    Full text: Since the establishment of the first German personal monitoring services as competent measuring bodies in the year 1952, official personal dosimetry is carried out using passive dosimeters such as film batches, RPL- and TL-dosimeters solely. On the other hand, electronic dosimeters are in use in some big institutions like Nuclear Power Plants, hospitals or industrial units for operational purposes. In most cases, these dosimeters are regulated by competent authorities. For more than 20 years electronic dosimeters proved their worth of being appropriate personal dosimeters. Since 2001 concepts to implement electronic personal dosimeters into the official individual monitoring of occupational exposed workers were developed in different research projects. The EU market of personal dosimetry changes to an open and competitive one, the number of outside workers, especially during the outages of Nuclear Power Plants increases, the landscape of customers is getting more and more heterogeneous. Being able to face these tasks of a sustainable personal monitoring requires the introduction of modern electronic dosimeters into to the official monitoring. Doing so, the needed prompt exchange of dose-data between different monitoring services as well as between the customers and the related monitoring service can be warranted. In cooperation with the industry, competent authorities and a research centre a method for official dosimetry using electronic dosimetry systems was developed, realised and tested successfully by the three big monitoring services of Germany. These investigations are supported by the German Federal Ministry for the Environment, Nature Conservation and Nuclear Safety. For this purpose a network between customers and monitoring services was built up in order to monitor people, who work in different places related to different measuring bodies in only one period of surveillance. (author)

  6. Personal radiation monitoring

    International Nuclear Information System (INIS)

    Julius, H.W.

    1976-01-01

    This report reviews the context of a primary university course in individual radiation monitoring. A brief account of the regulations and permissible doses is given. The principles and design of film dosemeters, thermoluminescent dosemeters and the whole-body counting technique are treated

  7. Design and construction of a personal radiation monitor

    International Nuclear Information System (INIS)

    Oliveira, A.H. de.

    1979-01-01

    The design and construction of a personal radiation monitor is dealt with. It provides a direct and reliable reading of the received dose, and sounds an alarm in the event of an excessive dose rate. A detailed analysis of its design, construction and caracteristics is given, as well a comparison with usual dosimeters. The apparatus is based on large-scale integrated electronics, it is reliable, easy to read, and can be used in the same manner as a film-badge. Contrariwise to both the film-badge and the termoluminescent dosimeters, it allows a direct reading. Also, it is not susceptible to false readings due to mechanical shocks, which is the weak point of the pocket ionization chamber. The dosimeter described herein is equipped with a special corrective shield that gives the correct dose reading, regardless of the photon energy. It is also highly immune to neutron interference. (Author) [pt

  8. Monitoring tablet surface roughness during the film coating process

    DEFF Research Database (Denmark)

    Seitavuopio, Paulus; Heinämäki, Jyrki; Rantanen, Jukka

    2006-01-01

    The purpose of this study was to evaluate the change of surface roughness and the development of the film during the film coating process using laser profilometer roughness measurements, SEM imaging, and energy dispersive X-ray (EDX) analysis. Surface roughness and texture changes developing during...... the process of film coating tablets were studied by noncontact laser profilometry and scanning electron microscopy (SEM). An EDX analysis was used to monitor the magnesium stearate and titanium dioxide of the tablets. The tablet cores were film coated with aqueous hydroxypropyl methylcellulose, and the film...... coating was performed using an instrumented pilot-scale side-vented drum coater. The SEM images of the film-coated tablets showed that within the first 30 minutes, the surface of the tablet cores was completely covered with a thin film. The magnesium signal that was monitored by SEM-EDX disappeared after...

  9. The use of film badges for personnel monitoring

    International Nuclear Information System (INIS)

    Ehrlich, M.

    1962-01-01

    Photographic film is fairly inexpensive and durable and as a result of irradiation its radiosensitive components undergo relatively permanent changes. With proper calibration the optical density of the development and fixed photographic film can be related to radiation exposure. Personnel monitoring with photographic film is the method of choice in many laboratories, and this manual gives guidelines for the use of photographic film in personnel dosimetry.

  10. Personal radiation monitoring with thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Miano, S.C.

    1987-01-01

    The technique of personal dosimetry used by SAPRA (Servico de Assessoria e Protecao Radiologica S/C Ltda., Brazil) is presented. Thermoluminescent monitors and CaSO 4 : Dy are used in pastilles united by teflon. Characteristics of the dosemeters are briefly reported. The system of thermoluminescent measurement, designed and constructed by SAPRA, and the system of personal monitoring are described. (M.A.C.) [pt

  11. Personal monitoring

    International Nuclear Information System (INIS)

    1995-01-01

    Sources of ionizing radiation have innumerable applications in the workplace. The potential exposures of the individual workers involved may need to be routinely monitored and records kept of their cumulative radiation doses. There are also occasions when it is necessary to retrospectively determine a dose which may have been received by a worker. This Module explains the basic terminology associated with personal monitoring and describes the principal types of dosimeters and other related techniques and their application in the workplace. The Manual will be of most benefit if it forms part of more comprehensive training or is supplemented by the advice of a qualified expert in radiation protection. Most of the dosimeters and techniques described in this Module can only be provided by qualified experts

  12. UNLAMINATED GAFCHROMIC EBT3 FILM FOR ULTRAVIOLET RADIATION MONITORING.

    Science.gov (United States)

    Welch, David; Randers-Pehrson, Gerhard; Spotnitz, Henry M; Brenner, David J

    2017-11-01

    Measurement of ultraviolet (UV) radiation is important for human health, especially with the expanded usage of short wavelength UV for sterilization purposes. This work examines unlaminated Gafchromic EBT3 film for UV radiation monitoring. The authors exposed the film to select wavelengths in the UV spectrum, ranging from 207 to 328 nm, and measured the change in optical density. The response of the film is wavelength dependent, and of the wavelengths tested, the film was most sensitive to 254 nm light, with measurable values as low as 10 µJ/cm2. The film shows a dose-dependent response that extends over more than four orders of magnitude. The response of the film to short wavelength UV is comparable to the daily safe exposure limits for humans, thus making it valuable as a tool for passive UV radiation monitoring. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Un-laminated Gafchromic EBT3 film for ultraviolet radiation monitoring

    International Nuclear Information System (INIS)

    Welch, David; Randers-Pehrson, Gerhard; Brenner, David J.; Spotnitz, Henry M.

    2017-01-01

    Measurement of ultraviolet (UV) radiation is important for human health, especially with the expanded usage of short wavelength UV for sterilization purposes. This work examines un-laminated Gafchromic EBT3 film for UV radiation monitoring. The authors exposed the film to select wavelengths in the UV spectrum, ranging from 207 to 328 nm, and measured the change in optical density. The response of the film is wavelength dependent, and of the wavelengths tested, the film was most sensitive to 254 nm light, with measurable values as low as 10 μJ/cm 2 . The film shows a dose-dependent response that extends over more than four orders of magnitude. The response of the film to short wavelength UV is comparable to the daily safe exposure limits for humans, thus making it valuable as a tool for passive UV radiation monitoring. (authors)

  14. Intercomparison of personal radiation monitoring services in the Asia/Pacific region- our participation

    International Nuclear Information System (INIS)

    Dhond, R.V.; Worlikar, R.M.; Saralamma Nair, D.; Pathak, A.S.; Sankaran, M.P.; Shenoy, K.S.; Patel, P.H.

    1994-01-01

    Radiation Protection Services Division participated in the intercomparison of personal monitoring services in Asia/Pacific region during 1991-92 organised by Australian Radiation Laboratory (ARL). The exposed films returned by ARL were processed in our laboratory. The nature and energies of the incident radiations were identified and doses evaluated in terms of new operational quantities. The doses evaluated were within ± 20% except in two cases where energy determination did not match with the ARL values. The results are presented in the paper. (author). 1 ref., 3 tabs

  15. The Recent System of the Personal Monitoring in the Czech Republic

    International Nuclear Information System (INIS)

    Petrova, K.

    2001-01-01

    Full text: The paper is intended to provide with the overview of the recent situation concerned to the management of the personal monitoring in the Czech Republic in the context of the harmonisation process of legislation within the European Union. New legislation concerning the radiation protection, which is effective in the Czech Republic from 1997 year, arises already from the ICRP 60 and IAEA BSS and includes all new basic principles for protection of radiation workers which are established and recommended. The recent Czech legislation does not recognise the term 'outside worker' and there are no special demands for their protection. However the harmonisation of the Czech legislation with EU Directives takes in consideration also the Council Directive 90/641/EURATOM on radiation protection of outside workers. In the frame of the process of harmonisation the new terms will be implemented into the Czech Atomic Law and new radiation passports will be tested in the practice. The personal dosimetric service is identified as the practice very significant from the radiation protection point of view and shall be licensed by the State Office for Nuclear Safety (SONS). The licence application shall include the methodology of effective dose evaluation, the description of quality assurance (QA) and quality control (QC) of the service, the system of customer communication and dose recording and reporting. The results of intercomparisons are demanded. The attention is paid also to the appropriate qualification of workers performing the service. Recently three dosimetric services are approved by SONS for external monitoring (film, TLD, electronic), four services for internal monitoring (whole-body counter, thyroid and bio samples measurement), one for monitoring in uranium mines and one for dose calculation of air crew. In accordance with legislation demands, the licensee (or dosimetric service monitoring the licensee's workers) is obliged to report the personal and

  16. Introduction of a new dosimetry system based on optically stimulated luminescence (OSL) in our personal monitoring service

    International Nuclear Information System (INIS)

    Hubner, S.

    2014-08-01

    The personal monitoring service named Auswertungsstelle is part of the Helmholtz Zentrum Munchen, a non-profit-making research center in Germany. As one of the four monitoring services in Germany, we have been a reliable partner in radiation protection for more than 60 years. With about 1.9 million dose assessments per year, we are the largest monitoring service in Europe. For dozens of years, our main dosimeter used in whole-body dosimetry has been a film dosimeter. Although its dosimetric properties are still up to date, film dosimetry won.t be a sustainable technique for the use in monitoring services. Therefore, a project with the objective of investigating alternative dosimetric materials and methods was launched in the late 1990 at the Helmholtz Zentrum Munchen. Based on this research work, the use of Be O as an OSL dosimeter was studied by the radiation physics group of the Tu Dresden, by order and on account of the Auswertungsstelle at the Helmholtz Zentrum Munchen. It was shown, that ceramic Be O features promising dosimetric properties, making Be O detectors particularly suitable for being used in all applications in whole-body dosimetry measuring photons. Ceramic Be O material has an excellent resistance to environmental influences. The Be O chips are almost tissue equivalent. Therefore, these detectors show low photon energy dependence. A new personal dosimetry system based on the OSL dosimetry of Be O was developed. Applying this system, the Auswertungsstelle offers OSL-dosimeters for official monitoring of the Personal Dose Equivalent Hp(10) since 2011. This OSL-System is accredited according to DIN IEC 62387 and we obtained the corresponding type approval by the Ptb, the national metrology institute in Germany. Sophisticated logistics was developed and installed. High degree of automation was achieved by robots for dosimeter assembly and machines for packing, labelling and unpacking of the dosimeters. To become a sustainable dosimetry system not only

  17. Introduction of a new dosimetry system based on optically stimulated luminescence (OSL) in our personal monitoring service

    Energy Technology Data Exchange (ETDEWEB)

    Hubner, S., E-mail: stephan.huebner@helmholtz-muenchen.de [Helmholtz Zentrum Munchen, German Research Center for Environmental Health, D-80219, Munich (Georgia)

    2014-08-15

    The personal monitoring service named Auswertungsstelle is part of the Helmholtz Zentrum Munchen, a non-profit-making research center in Germany. As one of the four monitoring services in Germany, we have been a reliable partner in radiation protection for more than 60 years. With about 1.9 million dose assessments per year, we are the largest monitoring service in Europe. For dozens of years, our main dosimeter used in whole-body dosimetry has been a film dosimeter. Although its dosimetric properties are still up to date, film dosimetry won.t be a sustainable technique for the use in monitoring services. Therefore, a project with the objective of investigating alternative dosimetric materials and methods was launched in the late 1990 at the Helmholtz Zentrum Munchen. Based on this research work, the use of Be O as an OSL dosimeter was studied by the radiation physics group of the Tu Dresden, by order and on account of the Auswertungsstelle at the Helmholtz Zentrum Munchen. It was shown, that ceramic Be O features promising dosimetric properties, making Be O detectors particularly suitable for being used in all applications in whole-body dosimetry measuring photons. Ceramic Be O material has an excellent resistance to environmental influences. The Be O chips are almost tissue equivalent. Therefore, these detectors show low photon energy dependence. A new personal dosimetry system based on the OSL dosimetry of Be O was developed. Applying this system, the Auswertungsstelle offers OSL-dosimeters for official monitoring of the Personal Dose Equivalent Hp(10) since 2011. This OSL-System is accredited according to DIN IEC 62387 and we obtained the corresponding type approval by the Ptb, the national metrology institute in Germany. Sophisticated logistics was developed and installed. High degree of automation was achieved by robots for dosimeter assembly and machines for packing, labelling and unpacking of the dosimeters. To become a sustainable dosimetry system not only

  18. Guidelines for personal exposure monitoring of chemicals: Part III.

    Science.gov (United States)

    Hashimoto, Haruo; Yamada, Kenichi; Hori, Hajime; Kumagai, Shinji; Murata, Masaru; Nagoya, Toshio; Nakahara, Hirohiko; Mochida, Nobuyuki

    2018-01-25

    This Document, "Guidelines for personal exposure monitoring of chemicals" ("this Guideline"), has been prepared by "The Committee for Personal Exposure Monitoring" ("the Committee") of the Expert Division of Occupational Hygiene & Ergonomics, Japan Society for Occupational Health. Considering the background of the growing importance of personal exposure monitoring in risk assessment and the need to prepare for the introduction of monitoring using personal samplers from an administrative perspective in recent years, the Committee was organized in November 2012. The Committee has prepared this Guideline as a "practical guideline" for personal exposure monitoring, so as to offer proposals and recommendations to the members of the Japan Society for Occupational Health and to society in general. The scope of this Guideline covers all chemical substances and all related workplaces regarded as targets for general assessment and the management of risk. It thus is not to be considered to comment on legal regulations and methodology. The main text provides the basic methods and concepts of personal exposure monitoring, while 31 "Appendices" are provided in this Guideline throughout the series; technical descriptions, statistical bases, and actual workplace examples are provided in these appendices, to assist better understanding. The personal exposure monitoring described as per this Guideline is equivalent to an "expert-centered basic method to reasonably proceed with the assessment and management of risk at workplaces." It is considered that practicing and expanding on this method will significantly contribute in reforming the overall framework of occupational hygiene management in Japan.

  19. Guidelines for personal exposure monitoring of chemicals: Part IV.

    Science.gov (United States)

    Hashimoto, Haruo; Yamada, Kenichi; Hori, Hajime; Kumagai, Shinji; Murata, Masaru; Nagoya, Toshio; Nakahara, Hirohiko; Mochida, Nobuyuki

    2018-03-27

    This Document, "Guidelines for personal exposure monitoring of chemicals" ("this Guideline"), has been prepared by "The Committee for Personal Exposure Monitoring" ("the Committee") of the Expert Division of Occupational Hygiene & Ergonomics, Japan Society for Occupational Health. Considering the background of the growing importance of personal exposure monitoring in risk assessment and the need to prepare for the introduction of monitoring using personal samplers from an administrative perspective in recent years, the Committee was organized in November 2012. The Committee has prepared this Guideline as a "practical guideline" for personal exposure monitoring, so as to offer proposals and recommendations to the members of the Japan Society for Occupational Health and to society in general. The scope of this Guideline covers all chemical substances and all related workplaces regarded as targets for general assessment and the management of risk. It thus is not to be considered to comment on legal regulations and methodology. The main text provides the basic methods and concepts of personal exposure monitoring, while 31 "Appendices" are provided in this Guideline throughout the series; technical descriptions, statistical bases, and actual workplace examples are provided in these appendices, to assist better understanding. The personal exposure monitoring described as per this Guideline is equivalent to an "expert-centered basic method to reasonably proceed with the assessment and management of risk at workplaces." It is considered that practicing and expanding on this method will significantly contribute in reforming the overall framework of occupational hygiene management in Japan.

  20. Guidelines for personal exposure monitoring of chemicals: Part II.

    Science.gov (United States)

    Hashimoto, Haruo; Yamada, Kenichi; Hori, Hajime; Kumagai, Shinji; Murata, Masaru; Nagoya, Toshio; Nakahara, Hirohiko; Mochida, Nobuyuki

    2017-11-25

    This Document, "Guidelines for personal exposure monitoring of chemicals" ("this Guideline"), has been prepared by "The Committee for Personal Exposure Monitoring" ("the Committee") of the Expert Division of Occupational Hygiene & Ergonomics, Japan Society for Occupational Health. Considering the background of the growing importance of personal exposure monitoring in risk assessment and the need to prepare for the introduction of monitoring using personal samplers from an administrative perspective in recent years, the Committee was organized in November 2012. The Committee has prepared this Guideline as a "practical guideline" for personal exposure monitoring, so as to offer proposals and recommendations to the members of the Japan Society for Occupational Health and to society in general. The scope of this Guideline covers all chemical substances and all related workplaces regarded as targets for general assessment and the management of risk. It thus is not to be considered to comment on legal regulations and methodology. The main text provides the basic methods and concepts of personal exposure monitoring, while 31 "Appendices" are provided in this Guideline throughout the series; technical descriptions, statistical bases, and actual workplace examples are provided in these appendices, to assist better understanding. The personal exposure monitoring described as per this Guideline is equivalent to an "expert-centered basic method to reasonably proceed with the assessment and management of risk at workplaces." It is considered that practicing and expanding on this method will significantly contribute in reforming the overall framework of occupational hygiene management in Japan.

  1. Guidelines for personal exposure monitoring of chemicals: Part I.

    Science.gov (United States)

    Hashimoto, Haruo; Yamada, Kenichi; Hori, Hajime; Kumagai, Shinji; Murata, Masaru; Nagoya, Toshio; Nakahara, Hirohiko; Mochida, Nobuyuki

    2017-09-28

    This Document, "Guidelines for personal exposure monitoring of chemicals" ("this Guideline"), has been prepared by "The Committee for Personal Exposure Monitoring" ("the Committee") of the Expert Division of Occupational Hygiene & Ergonomics, Japan Society for Occupational Health. Considering the background of the growing importance of personal exposure monitoring in risk assessment and the need to prepare for the introduction of monitoring using personal samplers from an administrative perspective in recent years, the Committee was organized in November 2012. The Committee has prepared this Guideline as a "practical guideline" for personal exposure monitoring, so as to offer proposals and recommendations to the members of the Japan Society for Occupational Health and to society in general. The scope of this Guideline covers all chemical substances and all related workplaces regarded as targets for general assessment and the management of risk. It thus is not to be considered to comment on legal regulations and methodology. The main text provides the basic methods and concepts of personal exposure monitoring, while 31 "Appendices" are provided later in this Guideline throughout the series; technical descriptions, statistical bases, and actual workplace examples are provided in these appendices, to assist better understanding. The personal exposure monitoring described as per this Guideline is equivalent to an "expert-centered basic method to reasonably proceed with the assessment and management of risk at workplaces." It is considered that practicing and expanding on this method will significantly contribute in reforming the overall framework of occupational hygiene management in Japan.

  2. Guidelines for personal exposure monitoring of chemicals: Part V.

    Science.gov (United States)

    Hashimoto, Haruo; Yamada, Kenichi; Hori, Hajime; Kumagai, Shinji; Murata, Masaru; Nagoya, Toshio; Nakahara, Hirohiko; Mochida, Nobuyuki

    2018-05-25

    This Document, "Guidelines for personal exposure monitoring of chemicals" ("this Guideline"), has been prepared by "The Committee for Personal Exposure Monitoring" ("the Committee") of the Expert Division of Occupational Hygiene & Ergonomics, Japan Society for Occupational Health. Considering the background of the growing importance of personal exposure monitoring in risk assessment and the need to prepare for the introduction of monitoring using personal samplers from an administrative perspective in recent years, the Committee was organized in November 2012. The Committee has prepared this Guideline as a "practical guideline" for personal exposure monitoring, so as to offer proposals and recommendations to the members of the Japan Society for Occupational Health and to society in general. The scope of this Guideline covers all chemical substances and all related workplaces regarded as targets for general assessment and the management of risk. It thus is not to be considered to comment on legal regulations and methodology. The main text provides the basic methods and concepts of personal exposure monitoring, while 31 "Appendices" are provided in this Guideline throughout the series; technical descriptions, statistical bases, and actual workplace examples are provided in these appendices, to assist better understanding. The personal exposure monitoring described as per this Guideline is equivalent to an "expert-centered basic method to reasonably proceed with the assessment and management of risk at workplaces." It is considered that practicing and expanding on this method will significantly contribute in reforming the overall framework of occupational hygiene management in Japan.

  3. Surface Acoustic Wave Monitor for Deposition and Analysis of Ultra-Thin Films

    Science.gov (United States)

    Hines, Jacqueline H. (Inventor)

    2015-01-01

    A surface acoustic wave (SAW) based thin film deposition monitor device and system for monitoring the deposition of ultra-thin films and nanomaterials and the analysis thereof is characterized by acoustic wave device embodiments that include differential delay line device designs, and which can optionally have integral reference devices fabricated on the same substrate as the sensing device, or on a separate device in thermal contact with the film monitoring/analysis device, in order to provide inherently temperature compensated measurements. These deposition monitor and analysis devices can include inherent temperature compensation, higher sensitivity to surface interactions than quartz crystal microbalance (QCM) devices, and the ability to operate at extreme temperatures.

  4. Performance test of personal RF monitor for area monitoring at magnetic confinement fusion facility

    International Nuclear Information System (INIS)

    Tanaka, M.; Uda, T.; Wang, J.; Fujiwara, O.

    2012-01-01

    For safety management at a magnetic confinement fusion-test facility, protection from not only ionising radiation, but also non-ionising radiation such as the leakage of static magnetic and electromagnetic fields is an important issue. Accordingly, the use of a commercially available personal RF monitor for multipoint area monitoring is proposed. In this study, the performance of both fast- and slow-type personal RF monitors was investigated by using a transverse electromagnetic cell system. The range of target frequencies was between 10 and 300 MHz, corresponding to the ion cyclotron range of frequency in a fusion device. The personal RF monitor was found to have good linearity, frequency dependence and isotropic response. However, the time constant for the electric field sensor of the slow-type monitor was much longer than that for the fast-type monitor. Considering the time-varying field at the facility, it is found that the fast-type monitor is suitable for multipoint monitoring at magnetic confinement fusion test facilities. (authors)

  5. Personal suicidality in reception and identification with suicidal film characters.

    Science.gov (United States)

    Till, Benedikt; Vitouch, Peter; Herberth, Arno; Sonneck, Gernot; Niederkrotenthaler, Thomas

    2013-04-01

    The authors investigated the impact of suicidality on identity work during film exposure. Adults with low suicidality (n = 150) watched either It's My Party or The Fire Within, censored versions of these films not depicting the suicide, or the control film that concluded with a non-suicidal death. Baseline suicidality was measured with questionnaires before the movie. Identity work and identification with the protagonist were measured after the movie. Suicidality was directly associated with identity work during film dramas depicting suicide methods. The reception of suicide-related media content seems to partially depend on personal suicidality. Potential implications for suicide prevention are discussed.

  6. Glass badge dosimetry system for large scale personal monitoring

    International Nuclear Information System (INIS)

    Norimichi Juto

    2002-01-01

    Glass Badge using silver activated phosphate glass dosemeter was specially developed for large scale personal monitoring. And dosimetry systems such as an automatic leader and a dose equipment calculation algorithm were developed at once to achieve reasonable personal monitoring. In large scale personal monitoring, both of precision for dosimetry and confidence for lot of personal data handling become very important. The silver activated phosphate glass dosemeter has basically excellent characteristics for dosimetry such as homogeneous and stable sensitivity, negligible fading and so on. Glass Badge was designed to measure 10 keV - 10 MeV range of photon. 300 keV - 3 MeV range of beta, and 0.025 eV - 15 MeV range of neutron by included SSNTD. And developed Glass Badge dosimetry system has not only these basic characteristics but also lot of features to keep good precision for dosimetry and data handling. In this presentation, features of Glass Badge dosimetry systems and examples for practical personal monitoring systems will be presented. (Author)

  7. Quality control of thermoluminesce personal dose monitoring

    International Nuclear Information System (INIS)

    Shang Aiguo; He Wenchang; Zhao Fengtao

    2006-01-01

    In order to evaluate the influence factor to thermoluminesce personal dose monitoring result, the every question that can appear based on the fact was analyzed. The results show that the detector, annealing, measuring process can influence the monitoring result. It gives some measures to enhance monitoring quality. (authors)

  8. Radiographic apparatus and method for monitoring film exposure time

    International Nuclear Information System (INIS)

    Vatne, R.S.; Woodmansee, W.E.

    1981-01-01

    In connection with radiographic inspection of structural and industrial materials, method and apparatus are disclosed for automatically determining and displaying the time required to expose a radiographic film positioned to receive radiation passed by a test specimen, so that the finished film is exposed to an optimum blackening (density) for maximum film contrast. A plot is made of the variations in a total exposure parameter (representing the product of detected radiation rate and time needed to cause optimum film blackening) as a function of the voltage level applied to an X-ray tube. An electronic function generator storing the shape of this plot is incorporated into an exposure monitoring apparatus, such that for a selected tube voltage setting, the function generator produces an electrical analog signal of the corresponding exposure parameter. During the exposure, another signal is produced representing the rate of radiation as monitored by a diode detector positioned so as to receive the same radiation that is incident on the film. The signal representing the detected radiation rate is divided, by an electrical divider circuit into the signal representing total exposure, and the resulting quotient is an electrical signal representing the required exposure time. (author)

  9. Radiological interference from personal articles in occupational radiation monitoring

    International Nuclear Information System (INIS)

    Krishnakumar, P.; Jayan, M.P; Pawar, V.J; Patil, S.L; Selvamani, N.; Vedram; Sureshkumar, M.K.; Chinnaesakki, S.

    2016-01-01

    This paper discusses the presence of radioactivity in some personal articles worn on sacred thread and the related difficulties faced by health physicists during occupational radiation monitoring in nuclear facilities. In an incident, the portal monitor installed at the exit gate of a nuclear facility indicated contamination on self of a radiation worker while passing through it. The worker was therefore, subjected to thorough check for external contamination by the plant health physicist, using a pan-cake contamination monitor. All the clothing of the person was also checked for contamination. On further detailed examination, a dark brownish personal article hanging on a sacred thread from his neck was found to be the source of contamination. This presentation aims at giving information to the health physics community on the possibility of such interferences during personal monitoring in nuclear facilities

  10. Personal monitoring for external sources of beta and low energy photon radiations

    Energy Technology Data Exchange (ETDEWEB)

    Christensen, P.; Herbaut, Y.; Marshall, T.O.

    1987-01-01

    In general, the dosemeters currently used for personal monitoring of beta and low energy photon doses suffer from an energy threshold problem because the detector and/or filter is too thick. Furthermore, current non-tissue-equivalent dosemeters, e.g. film dosemeters, are not provided with the filters needed to evaluate beta ray and low energy photon doses separately. To improve the present state of film dosemeters the thickness of the film wrapping paper should be reduced significantly and the badge should be provided with a number of pairs of thin filters. The dose evaluation from such a dosemeter is, however, complex and inaccurate and it seems unlikely that the required improvement is achievable at a reasonable cost. Improvement of tissue-equivalent dosemeters is possible by further development of multi-element dosemeters and thin detectors. The multi-element method has the advantage of using existing detectors, however the dose estimation is encumbered with high random error and the dosemeter design may become prohibitively expensive. The use of thin tissue-equivalent detectors implies a very simple badge design and an inherently accurate and uncomplicated dose evaluation. The development of adequate, thin, tissue-equivalent detectors suited for automated processing should therefore be encouraged.

  11. Personal monitoring for external sources of beta and low energy photon radiations

    International Nuclear Information System (INIS)

    Christensen, P.; Herbaut, Y.; Marshall, T.O.

    1987-01-01

    In general, the dosemeters currently used for personal monitoring of beta and low energy photon doses suffer from an energy threshold problem because the detector and/or filter is too thick. Furthermore, current non-tissue-equivalent dosemeters, e.g. film dosemeters, are not provided with the filters needed to evaluate beta ray and low energy photon doses separately. To improve the present state of film dosemeters the thickness of the film wrapping paper should be reduced significantly and the badge should be provided with a number of pairs of thin filters. The dose evaluation from such a dosemeter is, however, complex and inaccurate and it seems unlikely that the required improvement is achievable at a reasonable cost. Improvement of tissue-equivalent dosemeters is possible by further development of multi-element dosemeters and thin detectors. The multi-element method has the advantage of using existing detectors, however the dose estimation is encumbered with high random error and the dosemeter design may become prohibitively expensive. The use of thin tissue-equivalent detectors implies a very simple badge design and an inherently accurate and uncomplicated dose evaluation. The development of adequate, thin, tissue-equivalent detectors suited for automated processing should therefore be encouraged. (author)

  12. Real-time personal exposure and health condition monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Saitou, Isamu; Kanda, Hiroaki; Asai, Akio; Takeishi, Naoki; Ota, Yoshito [Hitachi Aloka Medical, Ltd., Measuring Systems Engineering Dept., Tokyo (Japan); Hanawa, Nobuhiro; Ueda, Hisao; Kusunoki, Tsuyoshi; Ishitsuka, Etsuo; Kawamura, Hiroshi [Japan Atomic Energy Agency, Oarai Research and Development Center, Oarai, Ibaraki (Japan)

    2012-03-15

    JAEA (Japan Atomic Energy Agency) and HAM (Hitachi Aloka Medical, Ltd) have proposed novel monitoring system for workers of nuclear facility. In these facilities, exposure management for workers is mainly used access control and personal exposure recordings. This system is currently only for reports management but is not confirmative for surveillance when work in progress. Therefore, JAEA and HAM integrate access control and personal exposure recordings and two real-time monitoring systems which are position sensing and vital sign monitor. Furthermore change personal exposure management to real-time management, this system integration prevents workers from risk of accidents, and makes possible take appropriate action quickly. This novel system is going to start for tentative operation, using position sensing and real-time personal dosimeter with database in Apr. 2012. (author)

  13. Standard Procedure for Dose Assessment using the film holder NRPB/AERE and the film AGFA Monitoring 2/10

    International Nuclear Information System (INIS)

    Guillen, J.A.

    1998-07-01

    This paper describes the calculation method to assess dose and energy using the film holder from NRPB/AERE and the film Agfa Monitoring 2/10. Also includes all the steps since preparing the standard curve, fitting of calibration curve, dose assesment, description of filtration of the film holder and the form of the calibration curve

  14. Automated personal dosimetry monitoring system for NPP

    International Nuclear Information System (INIS)

    Chanyshev, E.; Chechyotkin, N.; Kondratev, A.; Plyshevskaya, D.

    2006-01-01

    Full text: Radiation safety of personnel at nuclear power plants (NPP) is a priority aim. Degree of radiation exposure of personnel is defined by many factors: NPP design, operation of equipment, organizational management of radiation hazardous works and, certainly, safety culture of every employee. Automated Personal Dosimetry Monitoring System (A.P.D.M.S.) is applied at all nuclear power plants nowadays in Russia to eliminate the possibility of occupational radiation exposure beyond regulated level under different modes of NPP operation. A.P.D.M.S. provides individual radiation dose registration. In the paper the efforts of Design Bureau 'Promengineering' in construction of software and hardware complex of A.P.D.M.S. (S.H.W. A.P.D.M.S.) for NPP with PWR are presented. The developed complex is intended to automatize activities of radiation safety department when caring out individual dosimetry control. The complex covers all main processes concerning individual monitoring of external and internal radiation exposure as well as dose recording, management, and planning. S.H.W. A.P.D.M.S. is a multi-purpose system which software was designed on the modular approach. This approach presumes modification and extension of software using new components (modules) without changes in other components. Such structure makes the system flexible and allows modifying it in case of implementation a new radiation safety requirements and extending the scope of dosimetry monitoring. That gives the possibility to include with time new kinds of dosimetry control for Russian NPP in compliance with IAEA recommendations, for instance, control of the equivalent dose rate to the skin and the equivalent dose rate to the lens of the eye S.H.W. A.P.D.M.S. provides dosimetry control as follows: Current monitoring of external radiation exposure: - Gamma radiation dose measurement using radio-photoluminescent personal dosimeters. - Neutron radiation dose measurement using thermoluminescent

  15. Privacy by design in personal health monitoring.

    Science.gov (United States)

    Nordgren, Anders

    2015-06-01

    The concept of privacy by design is becoming increasingly popular among regulators of information and communications technologies. This paper aims at analysing and discussing the ethical implications of this concept for personal health monitoring. I assume a privacy theory of restricted access and limited control. On the basis of this theory, I suggest a version of the concept of privacy by design that constitutes a middle road between what I call broad privacy by design and narrow privacy by design. The key feature of this approach is that it attempts to balance automated privacy protection and autonomously chosen privacy protection in a way that is context-sensitive. In personal health monitoring, this approach implies that in some contexts like medication assistance and monitoring of specific health parameters one single automatic option is legitimate, while in some other contexts, for example monitoring in which relatives are receivers of health-relevant information rather than health care professionals, a multi-choice approach stressing autonomy is warranted.

  16. Human action pattern monitor for telecare system utilizing magnetic thin film infrared sensor

    International Nuclear Information System (INIS)

    Osada, H.; Chiba, S.; Oka, H.; Seki, K.

    2002-01-01

    The magnetic thin film infrared sensor (MFI) is an infrared sensing device utilizing a temperature-sensitive magnetic thin film with marked temperature dependence in the room temperature range. We propose a human action pattern monitor (HPM) constructed with the MFI, without a monitor camera to save the clients' privacy, as a telecare system

  17. Fine PM measurements: personal and indoor air monitoring.

    Science.gov (United States)

    Jantunen, M; Hänninen, O; Koistinen, K; Hashim, J H

    2002-12-01

    This review compiles personal and indoor microenvironment particulate matter (PM) monitoring needs from recently set research objectives, most importantly the NRC published "Research Priorities for Airborne Particulate Matter (1998)". Techniques and equipment used to monitor PM personal exposures and microenvironment concentrations and the constituents of the sampled PM during the last 20 years are then reviewed. Development objectives are set and discussed for personal and microenvironment PM samplers and monitors, for filter materials, and analytical laboratory techniques for equipment calibration, filter weighing and laboratory climate control. The progress is leading towards smaller sample flows, lighter, silent, independent (battery powered) monitors with data logging capacity to store microenvironment or activity relevant sensor data, advanced flow controls and continuous recording of the concentration. The best filters are non-hygroscopic, chemically pure and inert, and physically robust against mechanical wear. Semiautomatic and primary standard equivalent positive displacement flow meters are replacing the less accurate methods in flow calibration, and also personal sampling flow rates should become mass flow controlled (with or without volumetric compensation for pressure and temperature changes). In the weighing laboratory the alternatives are climatic control (set temperature and relative humidity), and mechanically simpler thermostatic heating, air conditioning and dehumidification systems combined with numerical control of temperature, humidity and pressure effects on flow calibration and filter weighing.

  18. Automatic scanning of NTA film neutron dosimeters

    CERN Document Server

    Müller, R

    1999-01-01

    At the European Laboratory for Particle Physics CERN, personal neutron monitoring for over 4000 collaborators is performed with Kodak NTA film, one of the few suitable dosemeters in the stray radiation environment of a high energy accelerator. After development, films are scanned with a projection microscope. To overcome this lengthy and strenuous procedure an automated analysis system for the dosemeters has been developed. General purpose image recognition software, tailored to the specific needs with a macro language, analyses the digitised microscope image. This paper reports on the successful automatic scanning of NTA films irradiated with neutrons from a /sup 238/Pu-Be source (E approximately=4 MeV), as well as on the extension of the method to neutrons of higher energies. The question of detection limits is discussed in the light of an application of the method in routine personal neutron monitoring. (9 refs).

  19. Elementary introduction for personal dose monitoring

    International Nuclear Information System (INIS)

    Bai Guang

    2004-01-01

    According to national laws and regulations, personnel who work with radiation must wear personal dosimeters and receive personal dose monitoring (PDM) provided by professional establishments, which are qualified for this purpose and certificated by the authorities. In this paper, the author gives a brief discussion concerning the Regulations & Purpose of PDM and the historical lessons in accident exposure without PDM. At last, it is pointed out that the PDM provided by the third-party commercial organizations is becoming the trend in this field. (author)

  20. Radon-film-badges by solid radiators to complement track detector-based radon monitors

    International Nuclear Information System (INIS)

    Tommasino, L.; Tommasino, M.C.; Viola, P.

    2009-01-01

    Existing passive radon monitors, based on track detectors, present many shortcomings, such as a limited response sensitivity for one-week-indoor measurements and a limited response linearity for the assessment of large radon exposures indoors, in thermal spa, in caves, and in soil. Moreover, for in-soil measurements these monitors are too bulky and are often conducive to wrong results. For what concerns the radon-in-water measurements, they are just not suitable. A new generation of passive radon monitors is introduced in this paper, which are very similar to the compact badges used in neutron- and gamma-dosimetry and will be referred to as radon-film-badges. These film-badges are formed by thin-film radiators with suitable radon-sorption characteristics, facing track detectors. The key strategy adopted for these radiators is to exploit an equilibrium type of radon sorption in solids. Even though this new generation of passive monitors is at its infancy, it appears already clear that said monitors make it finally possible to overcome most of the shortcomings of existing passive radon monitors. These devices are uniquely simple and can be easily acquired by any existing radon service to complement their presently used passive radon monitors with little or no effort.

  1. Surface Acoustic Wave (SAW Resonators for Monitoring Conditioning Film Formation

    Directory of Open Access Journals (Sweden)

    Siegfried Hohmann

    2015-05-01

    Full Text Available We propose surface acoustic wave (SAW resonators as a complementary tool for conditioning film monitoring. Conditioning films are formed by adsorption of inorganic and organic substances on a substrate the moment this substrate comes into contact with a liquid phase. In the case of implant insertion, for instance, initial protein adsorption is required to start wound healing, but it will also trigger immune reactions leading to inflammatory responses. The control of the initial protein adsorption would allow to promote the healing process and to suppress adverse immune reactions. Methods to investigate these adsorption processes are available, but it remains difficult to translate measurement results into actual protein binding events. Biosensor transducers allow user-friendly investigation of protein adsorption on different surfaces. The combination of several transduction principles leads to complementary results, allowing a more comprehensive characterization of the adsorbing layer. We introduce SAW resonators as a novel complementary tool for time-resolved conditioning film monitoring. SAW resonators were coated with polymers. The adsorption of the plasma proteins human serum albumin (HSA and fibrinogen onto the polymer-coated surfaces were monitored. Frequency results were compared with quartz crystal microbalance (QCM sensor measurements, which confirmed the suitability of the SAW resonators for this application.

  2. Preference for Graphic Horror Featuring Male versus Female Victimization: Personality and Past Film Viewing Experiences.

    Science.gov (United States)

    Tamborini, Ron; And Others

    1987-01-01

    Investigates the relationship of personality and past film viewing experiences to preferences for different degrees of graphic horror in film, and for female versus male victimization. Finds that the Machiavellian trait of deceit, past exposure to horror films, and, for male subjects only, the enjoyment of pornography were good predictors. (SR)

  3. Wearable strain sensors based on thin graphite films for human activity monitoring

    Science.gov (United States)

    Saito, Takanari; Kihara, Yusuke; Shirakashi, Jun-ichi

    2017-12-01

    Wearable health-monitoring devices have attracted increasing attention in disease diagnosis and health assessment. In many cases, such devices have been prepared by complicated multistep procedures which result in the waste of materials and require expensive facilities. In this study, we focused on pyrolytic graphite sheet (PGS), which is a low-cost, simple, and flexible material, used as wearable devices for monitoring human activity. We investigated wearable devices based on PGSs for the observation of elbow and finger motions. The thin graphite films were fabricated by cutting small films from PGSs. The wearable devices were then made from the thin graphite films assembled on a commercially available rubber glove. The human motions could be observed using the wearable devices. Therefore, these results suggested that the wearable devices based on thin graphite films may broaden their application in cost-effective wearable electronics for the observation of human activity.

  4. Individual monitoring in high-energy stray radiation fields

    International Nuclear Information System (INIS)

    Hoefert, M.; Stevenson, G.R.

    1995-01-01

    Due to the lack of passive or active devices that could be considered as personal dosemeters in high-energy stray fields one can at present only perform individual monitoring around high energy accelerators. Of all detectors currently available it is shown that the NTA film is the most suitable method for individually monitoring the neutron exposure of more than 3000 persons regularly, reliably, and cost effectively like at CERN. (author)

  5. Personal radiation monitoring and assessment of doses received by radiation workers (1991)

    International Nuclear Information System (INIS)

    Morris, N.D.

    1992-06-01

    The Australian Radiation Laboratory has operated a Personal Radiation Monitoring Service since the early 1930's so that people working with radiation can determine the radiation doses that they receive due to their occupation. Since late 1986, all persons monitored by the Service have been registered on a data base which maintains records of the doses received by each individual wearer. Ultimately, this data base will become a National Register of the doses received within Australia. At present, the Service regularly monitors approximately 20,000 persons, which is roughly 70 percent of those monitored in Australia, and maintains dose histories of over 35,000 people. The skin dose for occupationally exposed workers can be measured by using one of the four types of monitor issued by the Service: 1. Thermoluminescent Dosemeter (TLD monitor) 2. Finger TLD 3. Neutron Monitor 4. Special TLD. The technical description of the monitors is provided along with the method for calculating the radiation dose. 5 refs., 7 tabs., 4 figs

  6. Development of personal dose monitoring system using wireless data transmission device

    International Nuclear Information System (INIS)

    Inui, Daisuke; Nakashima, Sadao

    2008-01-01

    Radiation workers working in radiation controlled area in nuclear power plants etc., are required to carry a dosimeters by regulation law. The workers are controlled daily on personal exposure dose by reading out the exposure dose information of the dosimeters with an area access control gate installed at the entrance of the radiation controlled area. This type of personal dose monitoring system has a problem that each worker can get his personal dose data only at the entrance of the radiation controlled area several times a day. We developed a system to get the real-time acquisition of personal dose data especially for workers working in a high dose area. This system is generally composed of a dosimeter with a wireless attachment, relay station, and monitor. Some relay stations set in main work places in the radiation controlled area can collect real-time personal dose data of each dosimeter carried by workers at the work place with the relay stations, and transmit it to the monitor to get personal dose data of individual workers. A wireless communication system between dosimeters and relay stations is applied to collect efficiently all personal dose data in the work place. (author)

  7. Monitoring the thinning dynamics of soap films by phase shift interferometry. The case of perfluoropolyether surfactants.

    Science.gov (United States)

    Gambi, Cecilia M C; Vannoni, Maurizio; Sordini, Andrea; Molesini, Giuseppe

    2014-02-01

    An interferometric method to monitor the thinning process of vertical soap films from a water solution of surfactant materials is reported. Raw data maps of optical path difference introduced by the film are obtained by conventional phase shift interferometry. Off-line re-processing of such raw data taking into account the layered structure of soap films leads to an accurate measurement of the geometrical thickness. As an example of data acquisition and processing, the measuring chain is demonstrated on perfluoropolyether surfactants; the section profile of vertical films is monitored from drawing to black film state, and quantitative data on the dynamics of the thinning process are presented. The interferometric method proves effective to the task, and lends itself to further investigate the physical properties of soap films.

  8. An automatic evaluation system for NTA film neutron dosimeters

    CERN Document Server

    Müller, R

    1999-01-01

    At CERN, neutron personal monitoring for over 4000 collaborators is performed with Kodak NTA films, which have been shown to be the most suitable neutron dosimeter in the radiation environment around high-energy accelerators. To overcome the lengthy and strenuous manual scanning process with an optical microscope, an automatic analysis system has been developed. We report on the successful automatic scanning of NTA films irradiated with sup 2 sup 3 sup 8 Pu-Be source neutrons, which results in densely ionised recoil tracks, as well as on the extension of the method to higher energy neutrons causing sparse and fragmentary tracks. The application of the method in routine personal monitoring is discussed. $9 overcome the lengthy and strenuous manual scanning process with an optical microscope, an automatic analysis system has been developed. We report on the successful automatic scanning of NTA films irradiated with /sup 238/Pu-Be source $9 discussed. (10 refs).

  9. Personal radiation monitoring and assessment of doses received by radiation workers (1996)

    International Nuclear Information System (INIS)

    Morris, N.D.

    1996-12-01

    Since late 1986, all persons monitored by the Australian Radiation Laboratory have been registered on a data base which maintains records of the doses received by each individual wearer. At present, the Service regularly monitors approximately 30,000 persons, which is roughly 90 percent of those monitored in Australia, and maintains dose histories of over 75,000 people. The skin dose for occupationally exposed workers can be measured by using one of the five types of monitor issued by the Service: Thermoluminescent Dosemeter (TLD monitor), Finger TLD 3, Neutron Monitor, Special TLD and Environmental monitor. The technical description of the monitors is provided along with the method for calculating the radiation dose. 5 refs., 7 tabs., 5 figs

  10. A practical approach towards minimisation of latent image fading in personnel monitoring films

    International Nuclear Information System (INIS)

    Dhond, R.V.; Patel, P.H.; Shenoy, K.S.; Adtani, M.M.

    1980-01-01

    A serious drawback of the film badges used in personnel monitoring is the latent image fading often as high as 95% when they are subjected to extreme climatic conditions such as high humidities and temperatures. Current data on latent image fading in personnel monitoring films of various brands of manufacturers (Kodak, Agfa-Gevaert, Du Pont) are summarized. If individual film packs are hermitically sealed in polythene envelopes, fading is reduced to 20%. Studies were, therefore, conducted on Kodak type 2 films to observe the radiation response of films subjected alternatively to humid (20deg C and 90% r.h.) conditions for 8 hours and dry (20deg C and 30 to 40% r.h.) conditions for 16 hours with a view to find out a practicable and simple method to minimise the error due to fading. The films were then exposed to 600, 1200, 2400 and 4800 mR of radium-226 gammas after one week of storage and replaced in their experimental conditions. The films were processed after zero, one and two weeks of their storage in their respective conditions. Dose versus density curves of films were plotted. A fading less than 10% is shown for a storage period of two weeks. It is also suggested that films be kept in a desiccator having dry silica gel crystals during the periods when they are not being worn by the radiation workers. (M.G.B.)

  11. X-ray beam monitor made by thin-film CVD single-crystal diamond.

    Science.gov (United States)

    Marinelli, Marco; Milani, E; Prestopino, G; Verona, C; Verona-Rinati, G; Angelone, M; Pillon, M; Kachkanov, V; Tartoni, N; Benetti, M; Cannatà, D; Di Pietrantonio, F

    2012-11-01

    A novel beam position monitor, operated at zero bias voltage, based on high-quality chemical-vapor-deposition single-crystal Schottky diamond for use under intense synchrotron X-ray beams was fabricated and tested. The total thickness of the diamond thin-film beam monitor is about 60 µm. The diamond beam monitor was inserted in the B16 beamline of the Diamond Light Source synchrotron in Harwell (UK). The device was characterized under monochromatic high-flux X-ray beams from 6 to 20 keV and a micro-focused 10 keV beam with a spot size of approximately 2 µm × 3 µm square. Time response, linearity and position sensitivity were investigated. Device response uniformity was measured by a raster scan of the diamond surface with the micro-focused beam. Transmissivity and spectral responsivity versus beam energy were also measured, showing excellent performance of the new thin-film single-crystal diamond beam monitor.

  12. Real-time personal dose monitoring and management system

    International Nuclear Information System (INIS)

    Zhang Zhiyong; Cheng Chang; Yang Huating; Liu Zhengshan; Deng Changming; Li Mei

    2000-01-01

    This paper mainly describes a real-time personal dose monitoring and management system. The system is composed of three parts that include SDM-98 semiconductor detector personal dosimeters, Data Readers and a Management System Software. It can be used for personal dose monitoring and management and other controlling actions in a radioactive controlled area. Adopting semiconductor detector and microcontroller, SDM-98 Personal Dosimeter is used to measure personal accumulated dose equivalent and dose rate caused by X-ray and Gamma ray. The results can be read directly on LCD. All the data stored in dosimeter can be transmitted into a data reader by infrared optical link. The alarm threshold can be adjusted successively in whole range of dose or dose rate. The Data Reader is an intelligent interface between the dosimeter and master computer. The data received from dosimeter will be sent to a master computer through RS-232 serial interface. According to the master computer's order, the Data Reader can turn on the dosimeter's power at entrance and shutdown it at exit. The Management System Software which written by Visual BASIC 5.0 runs on MS Win95. All the measuring data from dosimeters can be analyzed and treated according to requirements and stored in database. Therefore, some figures and tables relative to dose or rate can be shown on screen or printed out. (author)

  13. How conservative is routine personal dosimetry monitoring in diagnostic radiology?

    International Nuclear Information System (INIS)

    Boetticher, H. von; Lachmund, J.; Hoffmann, W.

    2007-01-01

    Purpose: Dose values obtained by official personal radiation exposure monitoring are often considered equivalent to the effective dose of a person. This paper provides estimates of the extent of deviation between the two dose concepts under various conditions. Materials and Methods: Doses for patients and personnel were measured using thermoluminescence dosimeters for five different geometries at three work settings in a radiology department. Patients and personnel were simulated with anthropomorphic phantoms. Different types of protective clothing as well as permanent protection shields were considered in the calculations. Results: Dose values obtained by official personal dose monitoring are conservative only for specific radiation protection situations. With state-of-the-art personal protective equipment (wrap-around style lead apron with thyroid shield), the ratio between effective dose and personal dose varies between 0.6 and 1.25. Without thyroid protection the official personal dose systematically underestimates the effective dose: for protective clothing with 0.5 mm lead equivalent without thyroid shielding, the effective dose exceeds the personal dose by factors between 1.7 and 3.1. If protective clothing with lead equivalent 0.35 mm is used, this factor varies between 1.1 and 1.82. (orig.)

  14. Crack width monitoring of concrete structures based on smart film

    International Nuclear Information System (INIS)

    Zhang, Benniu; Wang, Shuliang; Li, Xingxing; Zhang, Xu; Yang, Guang; Qiu, Minfeng

    2014-01-01

    Due to its direct link to structural security, crack width is thought to be one of the most important parameters reflecting damage conditions of concrete structures. However, the width problem is difficult to solve with the existing structural health monitoring methods. In this paper, crack width monitoring by means of adhering enameled copper wires with different ultimate strains on the surface of structures is proposed, based on smart film crack monitoring put forward by the present authors. The basic idea of the proposed method is related to a proportional relationship between the crack width and ultimate strain of the broken wire. Namely, when a certain width of crack passes through the wire, some low ultimate strain wires will be broken and higher ultimate strain wires may stay non-broken until the crack extends to a larger scale. Detection of the copper wire condition as broken or non-broken may indicate the width of the structural crack. Thereafter, a multi-layered stress transfer model and specimen experiment are performed to quantify the relationship. A practical smart film is then redesigned with this idea and applied to Chongqing Jiangjin Yangtze River Bridge. (paper)

  15. Crack width monitoring of concrete structures based on smart film

    Science.gov (United States)

    Zhang, Benniu; Wang, Shuliang; Li, Xingxing; Zhang, Xu; Yang, Guang; Qiu, Minfeng

    2014-04-01

    Due to its direct link to structural security, crack width is thought to be one of the most important parameters reflecting damage conditions of concrete structures. However, the width problem is difficult to solve with the existing structural health monitoring methods. In this paper, crack width monitoring by means of adhering enameled copper wires with different ultimate strains on the surface of structures is proposed, based on smart film crack monitoring put forward by the present authors. The basic idea of the proposed method is related to a proportional relationship between the crack width and ultimate strain of the broken wire. Namely, when a certain width of crack passes through the wire, some low ultimate strain wires will be broken and higher ultimate strain wires may stay non-broken until the crack extends to a larger scale. Detection of the copper wire condition as broken or non-broken may indicate the width of the structural crack. Thereafter, a multi-layered stress transfer model and specimen experiment are performed to quantify the relationship. A practical smart film is then redesigned with this idea and applied to Chongqing Jiangjin Yangtze River Bridge.

  16. Comparison of two personal ultraviolet index monitors for sun awareness in South Africa

    Directory of Open Access Journals (Sweden)

    Caradee Y. Wright

    2013-01-01

    Full Text Available Exposure to solar ultraviolet (UV radiation is known to have both adverse and beneficial consequences for human health. Sunburn and skin cancer are probably the most well-known acute and chronic adverse health impacts. These themes have recently been discussed in the media for the general public; consequently interest in sun protection is growing. The promotion of the use of practical personal strategies to reduce adverse health risks, such as healthy sun behaviour, sun protection mechanisms and solar ultraviolet radiation awareness tools, is increasing. One such tool is the personal UV index (UVI monitor, promoted commercially as a viable tool for sun awareness; however, such instruments have not been scientifically evaluated in a South African context. Here, two different types of personal UVI monitors, commercially available in South Africa, were compared with a research-grade UVB biometer for a continuous 7-h period on 02 March 2012 in Pretoria. One of the two personal UVI monitors showed reasonable agreement with the UVB biometer, whereas the other monitor overestimated UVI by up to 4 UVI units. When comparing two identical products manufactured by the same company, one monitor overestimated UVI twofold, suggesting inter-instrument variability may be a concern. Commercially available, personal UVI monitors should be used with caution as a public health tool for sun awareness in South Africa.

  17. Production of Inorganic Thin Scintillating Films for Ion Beam Monitoring Devices

    CERN Document Server

    Re, Maurizio; Cosentino, Luigi; Cuttone, Giacomo; Finocchiaro, Paolo; Hermanne, Alex; Lojacono, Pietro A; Ma, YingJun; Thienpont, Hugo; Van Erps, Jurgen; Vervaeke, Michael; Volckaerts, Bart; Vynck, Pedro

    2005-01-01

    In this work we present the development of beam monitoring devices consisting of thin CsI(Tl) films deposited on Aluminium support layers. The light emitted by the scintillating layer during the beam irradiation is measured by a CCD-camera. In a first prototype a thin Aluminium support layer of 6 micron allows the ion beam to easily pass through without significant energy loss and scattering effects. Therefore it turns out to be a non-destructive monitoring device to characterize on-line beam shape and beam position without interfering with the rest of the irradiation process. A second device consists of an Aluminium support layer which is thick enough to completely stop the impinging ions allowing to monitor at the same time the beam profile and the beam current intensity. Some samples have been coated by a 100 Å protective layer to prevent the film damage by atmosphere exposition. In this contribution we present our experimental results obtained by irradiating the samples with proton beams at 8.3 and 62 Me...

  18. Occupational radiation exposure in Germany: many monitored persons = high exposure?

    International Nuclear Information System (INIS)

    Nitschke, J.

    1996-01-01

    Natural radiation affects the entire population in Germany, and most of Germany's inhabitants are exposed to medical radiation in their lifetime. Occupational radiation exposure, however, is a kind of exposure affecting only a limited and well-defined group of the population, and this radiation exposure has been recorded and monitored as precisely as technically possible ever since the radiation protection laws made occupational radiation exposure monitoring a mandatory obligation. Official personal dosimetry applying passive dosemeters in fact does not offer direct protection against the effects of ionizing radiation, as dosemeter read-out and dose calculation is a post-exposure process. But it nevertheless is a rewarding monitoring duty under radiation protection law, as is shown by the radiation exposure statistics accumulated over decades: in spite of the number of monitored persons having been increasing over the years, the total exposure did not, due to the corresponding improvements in occupational radiation protection. (orig.) [de

  19. Personal exposure versus monitoring station data for respirable particles

    Energy Technology Data Exchange (ETDEWEB)

    Sega, K; Fugas, M

    1982-01-01

    Personal exposure to respirable particles of 12 subjects working at the same location, but living in various parts of Zagreb, was monitored for 7 consecutive days and compared with simultaneously obtained data from the outdoor network station nearest to subject's home. Although personal exposure is related to the outdoor pollution, other sources play a considerable role. Indoor exposure takes, on the average, more than 80% of the total time. The ratio between average personal exposure and respirable particle levels in the outdoor air decreases with the increased outdoor concentration (r = -0.93), indicating that this relationship might serve as a basis for a rough estimate of possible personal exposure.

  20. Film badge personnel monitoring and dose distribution of industrial and medical workers in the country (1994-1998)

    International Nuclear Information System (INIS)

    Mittal, Hariom; Pandey, R.L.; Massand, O.P.

    2001-03-01

    Personnel Monitoring Section, Bhabha Atomic Research Centre, Mumbai, is entrusted with the responsibility of providing a countrywide personnel monitoring to radiation workers using extemal radiation like X, beta, gamma and neutron. As per Radiation Protection Rules (RPR) of 1971 promulgated by the competent authority the personnel monitoring service is mandatory for all the workers working with radiation. The radiation exposures received by them should be within the limits stipulated by AERB. Nearly 43,000 radiation workers in about 3000 DAE and non DAE institutions using radiation and radioisotopes are monitored, using both the Film Badges and the Thermoluminescent dosimeters. This report presents various aspects of film dosimetry which was introduced more than four decades ago in the country and also analysis of doses received by the radiation workers in the five year block 1994-1998 covered by film badge service. (author)

  1. State of the art in thin film thickness and deposition rate monitoring sensors

    International Nuclear Information System (INIS)

    Buzea, Cristina; Robbie, Kevin

    2005-01-01

    In situ monitoring parameters are indispensable for thin film fabrication. Among them, thickness and deposition rate control are often the most important in achieving the reproducibility necessary for technological exploitation of physical phenomena dependent on film microstructure. This review describes the types of thickness and deposition rate sensors and their theoretical and phenomenological background, underlining their performances, as well as advantages and disadvantages

  2. Personalized USB Biosensor Module for Effective ECG Monitoring.

    Science.gov (United States)

    Sladojević, Srdjan; Arsenović, Marko; Lončar-Turukalo, Tatjana; Sladojević, Miroslava; Ćulibrk, Dubravko

    2016-01-01

    The burden of chronic disease and associated disability present a major threat to financial sustainability of healthcare delivery systems. The need for cost-effective early diagnosis and disease prevention is evident driving the development of personalized home health solutions. The proposed solution presents an easy to use ECG monitoring system. The core hardware component is a biosensor dongle with sensing probes at one end, and micro USB interface at the other end, offering reliable and unobtrusive sensing, preprocessing and storage. An additional component is a smart phone, providing both the biosensor's power supply and an intuitive user application for the real-time data reading. The system usage is simplified, with innovative solutions offering plug and play functionality avoiding additional driver installation. Personalized needs could be met with different sensor combinations enabling adequate monitoring in chronic disease, during physical activity and in the rehabilitation process.

  3. Prediction of ultraviolet-induced damage during plasma processes in dielectric films using on-wafer monitoring techniques

    International Nuclear Information System (INIS)

    Ishikawa, Yasushi; Katoh, Yuji; Okigawa, Mitsuru; Samukawa, Seiji

    2005-01-01

    We measured electron-hole pairs generated in dielectric film using our developed on-wafer monitoring technique to detect electrical currents in the film during the plasma etching processes. The electron-hole pairs were generated by plasma induced ultraviolet (UV) photons, and the number of electron-hole pairs depends on the UV wavelength. In SiO 2 film, UV light, which has a wavelength of less than 140 nm, generates electron-hole pairs, because the band gap energy of the film is 8.8 eV. On the other hand, in Si 3 N 4 film, which has a band gap energy level of 5.0 eV, UV light below 250 nm induces the electron-hole pairs. Additionally, we evaluated the fluorocarbon gas plasma process that induces UV radiation damage using multilayer sensors that consisted of both SiO 2 and Si 3 N 4 stacked films. In these cases, electron-hole pair generation depended on the dielectric film structure. There were more electron-hole pairs generated in the SiO 2 deposited on the Si 3 N 4 film than in the Si 3 N 4 deposited on the SiO 2 film. As a result, our developed on-wafer monitoring sensor was able to predict electron-hole pair generation and the device characteristics

  4. A Sandwiched/Cracked Flexible Film for Multi-Thermal Monitoring and Switching Devices

    KAUST Repository

    Tai, Yanlong

    2017-08-30

    Polydimethylsiloxane (PDMS)-based flexible films have substantiated advantages in various sensing applications. Here, we demonstrate the highly sensitive and programmable thermal-sensing capability (thermal index, B, up to 126 × 103 K) of flexible films with tunable sandwiched microstructures (PDMS/cracked single-walled carbon nanotube (SWCNT) film/PDMS) when a thermal stimulus is applied. We found that this excellent performance results from the following features of the film\\'s structural and material design: (1) the sandwiched structure allows the film to switch from a three-dimensional to a two-dimensional in-plane deformation and (2) the stiffness of the SWCNT film is decreased by introducing microcracks that make deformation easy and that promote the macroscopic piezoresistive behavior of SWCNT crack islands and the microscopic piezoresistive behavior of SWCNT bundles. The PDMS layer is characterized by a high coefficient of thermal expansion (α = 310 × 10-6 K-1) and low stiffness (∼2 MPa) that allow for greater flexibility and higher temperature sensitivity. We determined the efficacy of our sandwiched, cracked, flexible films in monitoring and switching flexible devices when subjected to various stimuli, including thermal conduction, thermal radiation, and light radiation.

  5. Educating medical students about the personal meaning of terminal illness using the film, "Wit".

    Science.gov (United States)

    Ozcakir, Alis; Bilgel, Nazan

    2014-08-01

    Addressing the emotional needs of dying patients is rarely found to have a place in formal medical curriculum and is also a difficult area to teach through classical medical lectures. "Cinemeducation" is a wonderful way to educate health care providers about the magnitude of emotions that arise during those difficult situations. The aims of this study were to test the relevance and usefulness of the movie 'Wit' in teaching medical students about the personal meaning of terminal illness and to assess the impact of this teaching method on students' attitudes toward palliative care. This was an education study using qualitative and quantitative data analysis of 518 first-year medical students in a single medical faculty in Turkey. Students watched the entire film, filled out an evaluation questionnaire, and answered questions about the film. Students also expressed their own feelings and thoughts about palliative care. Overall, 88% rated the film as excellent, very good, or good. According to 54% of the students, the emotions of terminally ill patients were fully portrayed in the film and in a very realistic way. Approximately 61.4% of the students found this film emotional. Most students (80.5%) stated that this film made them think about the emotional and spiritual suffering that dying patients go through and found this learning approach about palliative care more useful than didactic lectures and journal article readings but not more useful than bedside rounds. It was thought that caring for dying patients would be very or fairly personally satisfying for 65.3% of the students. The film 'Wit' gave the students an opportunity to explore their beliefs, values and attitudes in terms of the bio-psycho-social-spiritual aspects of health care and encouraged them to think more about the humanitarian issues of the medical profession.

  6. Personal dosimetry and area monitoring for neutrons and radon in workplaces

    International Nuclear Information System (INIS)

    Tommasino, L.

    2001-01-01

    The first successful applications of damage track detectors in radiation protection have been made in the early 1970s in personal dosimetry of neutrons, radon and its progenies. Most of the scientists actively engaged in the solution of the complex problem of personal neutron dosimetry by damage track detectors-SSNTD, have attempted to develop individual radon monitoring for exposure in mines by using the same SSNTDs. In late 1970s and the early 1980s, new radon monitoring devices based on SSNTDs have been developed to measure radon in soil, mainly for applications in uranium prospecting or more generally in earth sciences. Most of the radon monitors, developed since then for completely different applications in mind, have been used later for large scale survey of indoor radon. With the current implementation within Europe of the European Union Directive 96/29, applications of damage track detectors will increase drastically, specially for the assessment of the exposure of the workers to natural sources of radiation. In this case, the early work on personal neutron/radon dosimetry, is highly valuable to tackle these new problems of individual monitoring

  7. A Sandwiched/Cracked Flexible Film for Multi-Thermal Monitoring and Switching Devices

    KAUST Repository

    Tai, Yanlong; Chen, Tao; Lubineau, Gilles

    2017-01-01

    Polydimethylsiloxane (PDMS)-based flexible films have substantiated advantages in various sensing applications. Here, we demonstrate the highly sensitive and programmable thermal-sensing capability (thermal index, B, up to 126 × 103 K) of flexible films with tunable sandwiched microstructures (PDMS/cracked single-walled carbon nanotube (SWCNT) film/PDMS) when a thermal stimulus is applied. We found that this excellent performance results from the following features of the film's structural and material design: (1) the sandwiched structure allows the film to switch from a three-dimensional to a two-dimensional in-plane deformation and (2) the stiffness of the SWCNT film is decreased by introducing microcracks that make deformation easy and that promote the macroscopic piezoresistive behavior of SWCNT crack islands and the microscopic piezoresistive behavior of SWCNT bundles. The PDMS layer is characterized by a high coefficient of thermal expansion (α = 310 × 10-6 K-1) and low stiffness (∼2 MPa) that allow for greater flexibility and higher temperature sensitivity. We determined the efficacy of our sandwiched, cracked, flexible films in monitoring and switching flexible devices when subjected to various stimuli, including thermal conduction, thermal radiation, and light radiation.

  8. Application of ubiquitous computing in personal health monitoring systems.

    Science.gov (United States)

    Kunze, C; Grossmann, U; Stork, W; Müller-Glaser, K D

    2002-01-01

    A possibility to significantly reduce the costs of public health systems is to increasingly use information technology. The Laboratory for Information Processing Technology (ITIV) at the University of Karlsruhe is developing a personal health monitoring system, which should improve health care and at the same time reduce costs by combining micro-technological smart sensors with personalized, mobile computing systems. In this paper we present how ubiquitous computing theory can be applied in the health-care domain.

  9. The Role of Personality in a Regular Cognitive Monitoring Program.

    Science.gov (United States)

    Sadeq, Nasreen A; Valdes, Elise G; Harrison Bush, Aryn L; Andel, Ross

    2018-02-20

    This study examines the role of personality in cognitive performance, adherence, and satisfaction with regular cognitive self-monitoring. One hundred fifty-seven cognitively healthy older adults, age 55+, completed the 44-item Big-Five Inventory and were subsequently engaged in online monthly cognitive monitoring using the Cogstate Brief Battery for up to 35 months (M=14 mo, SD=7 mo). The test measures speed and accuracy in reaction time, visual learning, and working memory tasks. Neuroticism, although not related to cognitive performance overall (P>0.05), was related to a greater increase in accuracy (estimate=0.07, P=0.04) and speed (estimate=-0.09, P=0.03) on One Card Learning. Greater conscientiousness was related to faster overall speed on Detection (estimate=-1.62, P=0.02) and a significant rate of improvement in speed on One Card Learning (estimate=-0.10, Pconscientiousness were observed. Participants volunteering for regular cognitive monitoring may be quite uniform in terms of personality traits, with personality traits playing a relatively minor role in adherence and satisfaction. The more neurotic may exhibit better accuracy and improve in speed with time, whereas the more conscientious may perform faster overall and improve in speed on some tasks, but the effects appear small.

  10. Accuracy and practicality of a portable ozone monitor for personal exposure estimates

    Science.gov (United States)

    Sagona, Jessica A.; Weisel, Clifford P.; Meng, Qingyu

    2018-02-01

    Accurate measurements of personal exposure to atmospheric pollutants such as ozone are important for understanding health risks. We tested a new personal ozone monitor (POM; 2B Technologies) for accuracy, precision, and ease of use. The POM's measurements were compared to simultaneous ozone measurements from a 2B Model 205 monitor and a ThermoScientific 49i monitor, and multiple POMs were placed side-by-side to check precision. Tests were undertaken in a controlled environmental facility, outdoors, and in a private residence. Additionally, ten volunteers wore a POM for five days and answered a questionnaire about its ease of use. The POM measured ozone accurately compared to the 49i ozone monitor, with average relative differences of less than 8%. In the controlled environment tests, the POM's ozone measurements did not change in the presence of additional atmospheric constituents with similar absorption lines to ozone, though there may have been a small decrease in precision and accuracy. Precision between POMs varied by environment (r2 = 0.98 outdoors; r2 = 0.3 to 0.9 in controlled lab conditions). Volunteers reported that the POM was reasonably comfortable to wear, although all reported that they felt that it was too noisy. Overall, the POM is a viable option for personal ozone monitoring.

  11. Personal monitoring in complex geometry of photon exposures

    International Nuclear Information System (INIS)

    Cunha, P.G.; Drexler, G.

    1996-01-01

    The ratio (effective dose, E) / (personal dose equivalent, Hp(10) ) was calculated for some scenarios set in broad parallel photon beams. Worker's irradiation condition are shown in which the number and locations of the individual monitor have to be carefully determined in order to avoid that the value of effective dose is underestimated

  12. Localizing the HL7 Personal Health Monitoring Record for Danish Telemedicine

    DEFF Research Database (Denmark)

    Christensen, Henrik Bærbak

    2014-01-01

    Telemedicine holds a promise of lowering cost in health care and improving the life quality of chronic ill patients by allowing monitoring in the home. The Personal Health Monitoring Record (PHMR) is an international HL7 standard data format for encoding measurements made by devices in the home...

  13. Individual differences in error monitoring in healthy adults: psychological symptoms and antisocial personality characteristics.

    Science.gov (United States)

    Chang, Wen-Pin; Davies, Patricia L; Gavin, William J

    2010-10-01

    Recent studies have investigated the relationship between psychological symptoms and personality traits and error monitoring measured by error-related negativity (ERN) and error positivity (Pe) event-related potential (ERP) components, yet there remains a paucity of studies examining the collective simultaneous effects of psychological symptoms and personality traits on error monitoring. This present study, therefore, examined whether measures of hyperactivity-impulsivity, depression, anxiety and antisocial personality characteristics could collectively account for significant interindividual variability of both ERN and Pe amplitudes, in 29 healthy adults with no known disorders, ages 18-30 years. The bivariate zero-order correlation analyses found that only the anxiety measure was significantly related to both ERN and Pe amplitudes. However, multiple regression analyses that included all four characteristic measures while controlling for number of segments in the ERP average revealed that both depression and antisocial personality characteristics were significant predictors for the ERN amplitudes whereas antisocial personality was the only significant predictor for the Pe amplitude. These findings suggest that psychological symptoms and personality traits are associated with individual variations in error monitoring in healthy adults, and future studies should consider these variables when comparing group difference in error monitoring between adults with and without disabilities. © 2010 The Authors. European Journal of Neuroscience © 2010 Federation of European Neuroscience Societies and Blackwell Publishing Ltd.

  14. Nutrient Film Technique (NFT Hydroponic Monitoring System

    Directory of Open Access Journals (Sweden)

    Helmy Helmy

    2016-10-01

    Full Text Available Plant cultivation using hydroponic is very popular today. Nutrient Film Technique (NFT hydroponic system is commonly used by people. It can be applied indoor or outdoor. Plants in this systemneed nutrient solution to grow well. pH, TDS and temperature of the nutrient solution must be check to ensure plant gets sufficient nutrients. This research aims todevelop monitoring system of NFT hydroponic. Farmer will be able to monitor pH, TDS and temperature online. It will ease farmer to decide which plant is suitable to be cultivated and time to boost growth.Delay of the system will be measured to know system performance. Result shows that pH is directly proportional with TDS. Temperature value has no correlation with pH and TDS. System has highest delay during daylight and afternoon but it will decline in the night and morning. Average of delay in the morning is 11 s, 28.5 s in daylight, 32 s in the afternoon and 17.5 s in the night.

  15. Individual monitoring of external exposure in terms of personal dose equivalent, Hp(d)

    International Nuclear Information System (INIS)

    Fantuzzi, E.

    2001-01-01

    The institute for Radiation Protection of ENEA - Bologna has organised a one day-workshop on the subject: Individual monitoring of external exposure in terms of personal dose equivalent, H p (d). The aim of the workshop was the discussion of the new implications and modifications to be expected in the routine individual monitoring of external radiation, due to the issue of the Decree 241/00 (G.U. 31/8/2000) in charge since 01/01/2001. The decree set up in Italian law the standards contained in the European Directive EURATOM 96/29-Basic Standards for the Protection of Health of Workers and the General Public against Dangers arising from Ionizing Radiation. Among others, the definition of the operational quantities for external radiation for personal and environmental monitoring, H p (d) e H * (d) respectively as defined by ICRU (International Commission for Radiation Units and Measurements), requires to update the methods of measurements and calibration of the personal dosemeters and environmental monitors. This report collects the papers presented at the workshop dealing with the Personal Dose Equivalent, H p (d), the conversion coefficients, H p (d)/K a e H p (d)/ , obtained through Monte Carlo calculations published by ICRU and ICRP (International Commission for Radiation Protection), the new calibration procedures and the practical implication in the routine of individual monitoring in terms of H p (d). Eventually, in the last chapter, the answers to Frequently Asked Questions (FAQ) are briefly reported [it

  16. Real body, fake person: Recontextualizing celebrity bodies in fandom and film

    Directory of Open Access Journals (Sweden)

    Melanie Piper

    2015-09-01

    Full Text Available Comparisons between real person fan fiction (RPF and film or television texts dramatizing real people have been made in debates over the ethics of RPF as a fan practice. In an effort to direct the scholarly focus on RPF from these ethical issues to the texts themselves, I propose examining the similarities between the textual process of adapting real people to fictional characters on both the cinema screen and the computer screen. This paper examines the work RPF writers do in appropriating the various bodies of their celebrity subjects: the fragmented intertextual body of the star image, and the celebrity's physical body as a signifier of star image and status as a real person in the world. I argue that the fannish textual process of adapting real public figures to fictional contexts shares a common element with adapting public figures to the screen in the biopic: both work to recontextualize the public self of a celebrity through the representation of a fictionalized or speculated private self. To illustrate this, I will be engaging with a case study of The Social Network (2010 fandom through works in its kink meme, and how the adaptations of textual bodies are at work in fictionalized fan writing about real actors performing in the Hollywood fictionalized film about real tech entrepreneurs.

  17. In situ ellipsometry — A powerful tool for monitoring alkali doping of organic thin films

    International Nuclear Information System (INIS)

    Haidu, F.; Ludemann, M.; Schäfer, P.; Gordan, O.D.; Zahn, D.R.T.

    2014-01-01

    The changes of the optical properties of several organic thin films induced by potassium doping were monitored using in situ spectroscopic ellipsometry. The samples were prepared in a high vacuum chamber by organic molecular deposition. Then, potassium (K) was evaporated by passing current through K getters. The three different organic molecules used, show very distinct and different spectral behaviour upon doping. While for Tris-(8-hydroxyquinoline)-aluminium(III) and N,N′-Di-[(1-naphthyl)-N,N′-diphenyl]-(1,1′-biphenyl)-4,4′-diamine only small shifts of the spectral features were noticed, Manganese Phthalocyanine revealed significant changes of the optical properties induced by the K doping. This work indicates that the K doping process can have a dramatic effect on the electronic and the optical properties of the organic molecules, but the effect on the optical spectra remains specific for each organic molecule used, and cannot be easily predicted. - Highlights: • Monitoring organic film growth and doping with in situ spectroscopic ellipsometry • K doped organic thin films • Optical properties of organic thin films change by K doping. • The changes in the optical spectra remain specific for each organic molecule used

  18. Film Reviews.

    Science.gov (United States)

    Lance, Larry M.; Atwater, Lynn

    1987-01-01

    Reviews four Human Sexuality films and videos. These are: "Personal Decisions" (Planned Parenthood Federation of America, 1985); "The Touch Film" (Sterling Production, 1986); "Rethinking Rape" (Film Distribution Center, 1985); "Not A Love Story" (National Film Board of Canada, 1981). (AEM)

  19. Contribution of various microenvironments to the daily personal exposure to ultrafine particles: Personal monitoring coupled with GPS tracking

    Science.gov (United States)

    Bekö, Gabriel; Kjeldsen, Birthe Uldahl; Olsen, Yulia; Schipperijn, Jasper; Wierzbicka, Aneta; Karottki, Dorina Gabriela; Toftum, Jørn; Loft, Steffen; Clausen, Geo

    2015-06-01

    Exposure to ultrafine particles (UFP) may have adverse health effects. Central monitoring stations do not represent the personal exposure to UFP accurately. Few studies have previously focused on personal exposure to UFP. Sixty non-smoking residents living in Copenhagen, Denmark were asked to carry a backpack equipped with a portable monitor, continuously recording particle number concentrations (PN), in order to measure the real-time individual exposure over a period of ˜48 h. A GPS logger was carried along with the particle monitor and allowed us to estimate the contribution of UFP exposure occurring in various microenvironments (residence, during active and passive transport, other indoor and outdoor environments) to the total daily exposure. On average, the fractional contribution of each microenvironment to the daily integrated personal exposure roughly corresponded to the fractions of the day the subjects spent in each microenvironment. The home environment accounted for 50% of the daily personal exposure. Indoor environments other than home or vehicles contributed with ˜40%. The highest median UFP concentration was obtained during passive transport (vehicles). However, being in transit or outdoors contributed 5% or less to the daily exposure. Additionally, the subjects recorded in a diary the periods when they were at home. With this approach, 66% of the total daily exposure was attributable to the home environment. The subjects spent 28% more time at home according to the diary, compared to the GPS. These results may indicate limitations of using diaries, but also possible inaccuracy and miss-classification in the GPS data.

  20. The current situation of personal dose monitoring in Chinese medicine radiation and undamaged detection

    International Nuclear Information System (INIS)

    Zhang Liangan; Zhang Wenyi; Yuan Shuyu; Song Shijun; Chang Hexin; Sun Kai

    1993-01-01

    The situation of personal dose monitoring in γ(X) external exposure in China is mainly outlined. Thermoluminescent dosimetry (TLD) was adopted for personal dose measurement of the radiation workers. The computer software and data base for the work have been developed and applied. National intercomparison of TLD, monitoring control of personal dose monitoring in field, and technical training were carried out for quality control. In China, the dominant occupational exposures is X-ray diagnosis and it increases year by year, the highest values is about 22.6%. The highest values of annual collective dose and annual average of individual dose (AAID) are 272.8 man·Sv and 3.21 mSv respectively. This work shows that the fraction of the population receiving high dose is decreased with time rapidly. The situation for whole occupational exposures is also described. (3 tabs.)

  1. An in-situ real-time optical fiber sensor based on surface plasmon resonance for monitoring the growth of TiO2 thin films.

    Science.gov (United States)

    Tsao, Yu-Chia; Tsai, Woo-Hu; Shih, Wen-Ching; Wu, Mu-Shiang

    2013-07-23

    An optical fiber sensor based on surface plasmon resonance (SPR) is proposed for monitoring the thickness of deposited nano-thin films. A side-polished multimode SPR optical fiber sensor with an 850 nm-LD is used as the transducing element for real-time monitoring of the deposited TiO2 thin films. The SPR optical fiber sensor was installed in the TiO2 sputtering system in order to measure the thickness of the deposited sample during TiO2 deposition. The SPR response declined in real-time in relation to the growth of the thickness of the TiO2 thin film. Our results show the same trend of the SPR response in real-time and in spectra taken before and after deposition. The SPR transmitted intensity changes by approximately 18.76% corresponding to 50 nm of deposited TiO2 thin film. We have shown that optical fiber sensors utilizing SPR have the potential for real-time monitoring of the SPR technology of nanometer film thickness. The compact size of the SPR fiber sensor enables it to be positioned inside the deposition chamber, and it could thus measure the film thickness directly in real-time. This technology also has potential application for monitoring the deposition of other materials. Moreover, in-situ real-time SPR optical fiber sensor technology is in inexpensive, disposable technique that has anti-interference properties, and the potential to enable on-line monitoring and monitoring of organic coatings.

  2. Environmental monitoring by thin film nanocomposite sensors for cultural heritage preservation

    International Nuclear Information System (INIS)

    Liu, Baoying; Chen, Xiaojiang; Fang, Dingyi; Perrone, Alessio; Pispas, Stergios; Vainos, Nikos A.

    2010-01-01

    Environmental control is a crucial issue in cultural heritage preservation as it especially relates to sensitive artwork and antique object conservation. Storage and transport of artworks and antiques are operations requiring precise control of the environment. Current technology trends lead to miniaturization of environmental sensor devices in which low power dissipation and advanced non-contact or remote monitoring methods appear to offer significant advantages. In the above context, nanocomposite materials represent innovative alternative solutions for high sensitivity temperature and relative humidity (RH) sensing. The control of both of these parameters, together with the exposure to ultraviolet radiation, is important in minimizing aging and deterioration of art and antique objects. New schemes reported here consider the classes of CN x and CoCl 2 nanocomposites. First, CN x thin films are synthesized on Si substrates by reactive pulsed laser ablation of graphite targets in N 2 atmosphere to form capacitive sensors. On the other hand, CoCl 2 polymer matrix composite films are produced by spin coating or casting of the composite polymer/CoCl 2 on planar glass substrates. These latter systems present a new class of optically interrogated photonic sensors featuring powerless sensing head and remote monitoring capabilities. The prototype devices proposed for use in art conservation and museum applications have been tested under controlled environmental conditions and their performance is seen to be comparable, and in some cases superior, to conventional monitoring solutions.

  3. A personal computer based console monitor for a TRIGA reactor

    International Nuclear Information System (INIS)

    Rieke, Phillip E.; Hood, William E.; Razvi, Junaid

    1990-01-01

    Numerous improvements have been made to the Mark F facility to provide a minimum reactor down time, giving a high reactor availability. A program was undertaken to enhance the monitoring capabilities of the instrumentation and control system on this reactor. To that end, a personal computer based console monitoring system has been developed, installed in the control room and is operational to provide real-time monitoring and display of a variety of reactor operating parameters. This system is based on commercially available hardware and an applications software package developed internally at the GA facility. It has (a) assisted the operator in controlling reactor parameters to maintain the high degree of power stability required during extended runs with thermionic devices in-core, and (b) provided data trending and archiving capabilities on all monitored channels to allow a post-mortem analysis to be performed on any of the monitored parameters

  4. Personal Dosimetry in UHC Sestre Milosrdnice: 10-Years Review

    International Nuclear Information System (INIS)

    Bokulic, T.; Budanec, M; Gregov, M.; Kusic, Z.; Mlinaric, M.; Mrcela, I.; Suric Mihic, M.

    2013-01-01

    Personal dose monitoring in UHC 'Sestre milosrdnice' is regulary performed for about 300 exposed workers involved in a variety of tasks with different sources of ionizing radiation. Exposed workers are required to wear personal dosimeters which are read on monthly basis and dose records are kept in the hospital. In this paper an overview of personal dosimetry data from year 2003 till 2013 is presented. Film dosimeters were used for personal dosimetry untill 2010 when the thermoluminescent (TL) dosimetry was introduced. Dosimeters are calibrated to measure personal dose equivalent H p (10). Received doses are analyzed for workers in the field of nuclear medicine, radiotherapy (external beam and brachytherapy), general diagnostic radiology and interventional radiology. Analysis of received doses in the whole period resulted with an average individual dose in nuclear medicine of 0.6 mSv/y, which decreased to 0.21 mSv/y in the last three years, caused by more precise dosimetric methods with TL dosimetry and improved conditions of radiation protection. In the same three-year period, in interventional radiology doses were 0.32 mSv/y, compared to 0.29 mSv/y obtained for a previous seven years. This was expected due to the escalation in a number of interventions and new installed equipment. There was no such difference in diagnostic radiology doses, showing that film dosimetry is suitable for x ray energies. Analysis of all the readings showed a significant influence of measurement procedures on personal dosimeter dose and also the importance of continuous monitoring of the dose records in order to improve the conditions of radiation protection and achieving the ALARA goal.(author)

  5. Person × Environment Interactions on Adolescent Delinquency: Sensation Seeking, Peer Deviance and Parental Monitoring.

    Science.gov (United States)

    Mann, Frank D; Kretsch, Natalie; Tackett, Jennifer L; Harden, K Paige; Tucker-Drob, Elliot M

    2015-04-01

    Sensation seeking is a personality trait that is robustly correlated with delinquent behavior in adolescence. The current study tested specific contextual factors hypothesized to facilitate, exacerbate or attenuate this risk factor for adolescent delinquency. Individual differences in sensation seeking, peer deviance, parental monitoring and self-reported delinquent behavior were assessed in a sample of 470 adolescents. Peer deviance partially mediated the effects of sensation seeking and parental monitoring on adolescent delinquency. We also found evidence for a three-way interaction between sensation seeking, peer deviance and parental monitoring, such that the highest rates of delinquency occurred from the concurrence of high sensation seeking, high peer deviance, and low levels of parental monitoring. Results highlight the importance of considering peer- and family-level processes when evaluating personality risk and problematic adolescent behavior.

  6. Intelligent poly (vinyl alcohol)-chitosan nanoparticles-mulberry extracts films capable of monitoring pH variations.

    Science.gov (United States)

    Ma, Qianyun; Liang, Tieqiang; Cao, Lele; Wang, Lijuan

    2018-03-01

    The aim of this study was to prepare a visually responsive intelligent film based on poly (vinyl alcohol) (PVA), chitosan nanoparticles (CHNPs) and mulberry extracts (MBE). CHNPs were first prepared by using ionotropic gelation method to enhance the mechanical properties of PVA based films. The morphology, particle size, zeta potential and crystallinity of CHNPs were measured. The resultant CHNPs were spherical with a diameter of 381.2nm, with high stability and a zeta potential of 49.1±1.33mV. The film with 6% CHNPs (P-C6) had the highest tensile strength (∼73.43MPa). MBE was incorporated into the P-C6 film. The film containing 20% MBE had the highest tensile strength and showed visible color responses to variations across pH 1-13. The film was tested by monitoring the spoilage of fish. The color of the film changed from red to green as the fish spoiled. Therefore, the pH responsive intelligent film developed here can be used as a package label to detect food spoilage. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Personal monitoring and assessment of doses received by radiation workers

    International Nuclear Information System (INIS)

    Swindon, T.N.; Morris, N.D.

    1981-12-01

    The Personal Radiation Monitoring Service operated by the Australian Radiation Laboratory is outlined and the types of monitors used for assessment of doses received by radiation workers are described. The distribution of doses received by radiation workers in different occupational categories is determined. From these distributions, the average doses received have been assessed and the maximum likely additional increase in cancer deaths in Australia as a result of occupational exposure estimated. This increase is shown to be very small. There is, however, a considerable spread of doses received by individuals within occupational groups

  8. Parallel analysis of film and TLD application in personal dosimetry of medical staff during application of invasive radiological procedures

    International Nuclear Information System (INIS)

    Misovic, M.; Boskovic, Z.; Spasic-Jokic, V.

    1997-01-01

    Although both types of dosimeters showed similar results for mentioned category of health care workers we wished to emphasize some advantages in use of TLD and film dosemeters in personal dosimetry. The main advantageous of film for dosimetric purposes are that it can provide visual representation of the radiation field and they are cheap, but there are lot of disadvantages. Advantages of TLD are based on: possibility for re-use, practically for whole users working life, small dimensions suitable for results, high precision and specially wide dose range. They are sensitive on low dose, practically for ten times more than film is. Disadvantages of TLD are based on their previous thermal and radiation history and on the fact that information about dose disappears after reading procedure. Considering advantages and disadvantages of both types of dosemeters we decided to propose TLD for routine hospital practice in personal dosimetry. (author)

  9. Automatic data acquisition system of environmental radiation monitor with a personal computer

    International Nuclear Information System (INIS)

    Ohkubo, Tohru; Nakamura, Takashi.

    1984-05-01

    The automatic data acquisition system of environmental radiation monitor was developed in a low price by using a PET personal computer. The count pulses from eight monitors settled at four site boundaries were transmitted to a radiation control room by a signal transmission device and analyzed by the computer via 12 channel scaler and PET-CAMAC Interface for graphic display and printing. (author)

  10. Personalized Health Monitoring System for Managing Well-Being in Rural Areas.

    Science.gov (United States)

    Nedungadi, Prema; Jayakumar, Akshay; Raman, Raghu

    2017-12-14

    Rural India lacks easy access to health practitioners and medical centers, depending instead on community health workers. In these areas, common ailments that are easy to manage with medicines, often lead to medical escalations and even fatalities due to lack of awareness and delayed diagnosis. The introduction of wearable health devices has made it easier to monitor health conditions and to connect doctors and patients in urban areas. However, existing initiatives have not succeeded in providing adequate health monitoring to rural and low-literate patients, as current methods are expensive, require consistent connectivity and expect literate users. Our design considerations address these concerns by providing low-cost medical devices connected to a low-cost health platform, along with personalized guidance based on patient physiological parameters in local languages, and alerts to medical practitioners in case of emergencies. This patient-centric integrated healthcare system is designed to manage the overall health of villagers with real-time health monitoring of patients, to offer guidance on preventive care, and to increase health awareness and self-monitoring at an affordable price. This personalized health monitoring system addresses the health-related needs in remote and rural areas by (1) empowering health workers in monitoring of basic health conditions for rural patients in order to prevent escalations, (2) personalized feedback regarding nutrition, exercise, diet, preventive Ayurveda care and yoga postures based on vital parameters and (3) reporting of patient data to the patient's health center with emergency alerts to doctor and patient. The system supports community health workers in the diagnostic procedure, management, and reporting of rural patients, and functions well even with only intermittent access to Internet.

  11. Smokers' Views on Personal Carbon Monoxide Monitors, Associated Apps, and Their Use: An Interview and Think-Aloud Study.

    Science.gov (United States)

    Herbeć, Aleksandra; Perski, Olga; Shahab, Lion; West, Robert

    2018-02-07

    Smartphone-based personal carbon monoxide (CO) monitors and associated apps, or "CO Smartphone Systems" (CSSs) for short, could enable smokers to independently monitor their smoking and quitting. This study explored views and preferences regarding CSSs and their use among 16 adult, UK-based smokers. First, semi-structured interviews explored participants' expectations of CSSs. Secondly, a think-aloud study identified participants' reactions to a personal CO monitor and to existing or prototype apps. Framework Analysis identified five themes: (1) General views, needs, and motivation to use CSSs; (2) Views on the personal CO monitor; (3) Practicalities of CSS use; (4) Desired features in associated apps; and (5) Factors affecting preferences for CSSs and their use. Participants had high expectations of CSSs and their potential to increase motivation. Priority app features included: easy CO testing journeys, relevant and motivating feedback, and recording of contextual data. Appearance and usability of the personal CO monitor, and accuracy and relevance of CO testing were considered important for engagement. Participants differed in their motivation to use and preferences for CSSs features and use, which might have non-trivial impact on evaluation efforts. Personal CO monitors and associated apps may be attractive tools for smokers, but making CSSs easy to use and evaluating these among different groups of smokers may be challenging.

  12. In-situ monitoring of the growth of nanostructured aluminum thin film

    Czech Academy of Sciences Publication Activity Database

    Novotný, Michal; Bulíř, Jiří; Lančok, Ján; Pokorný, Petr; Bodnár, Michal

    2011-01-01

    Roč. 5, č. 5 (2011), "051503-1"-"051503-10" ISSN 1934-2608 R&D Projects: GA AV ČR IAA100100718; GA AV ČR IAA100100729; GA ČR GP202/09/P324 Institutional research plan: CEZ:AV0Z10100522 Keywords : aluminum ultrathin film * magnetron sputtering * in-situ monitoring * electrical conductivity * spectral ellipsometry * optical emission spectroscopy Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.570, year: 2011

  13. WS-010: EPR-First Responders: Personal monitoring techniques and protective clothing

    International Nuclear Information System (INIS)

    2011-01-01

    The purpose of this working session is that the participant can apply their knowledge in relation to the personal monitoring techniques and protective clothing. They have to know the use of the radiation measurement instrumentation available in each region

  14. Internal quality control program for individual monitoring service

    Energy Technology Data Exchange (ETDEWEB)

    Mauricio, Claudia L.P.; Moura Junior, Jose; Patrao, Karla C.S. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)]. E-mail: claudia@ird.gov.br; moura@ird.gov.br; karla@ird.gov.br

    2007-07-01

    With a focus on continuous improvement, since 2002, a special internal procedure for following and checking the performance of our individual monitoring services has been implemented. A fictitious installation, named 'Fantasma' has been created, initially, with 4 film badges and 7 thermoluminescent dosimetric ring users. Since 2005, this quality control program includes also the albedo neutron individual monitoring service. Monthly, the 'Fantasma' test monitors are irradiated by traceable Cs-137 and Am-Be sources. The calibration quantities are: the photon dose equivalent (H{sub x}) for the photographic individual monitor, the maximum dose equivalent (MADE) for the albedo neutron individual monitor and the personal dose equivalent at 0.07 mm depth (H{sub p}(0.07)) for ring monitor. Up to now, all results show compliance with the specific trumpet curves acceptance limits. Once, a small sub-evaluation tendency has been noted and this information was used to improve the film system. For the photographic film system, the evaluated value to reference dose ratios range from 0.71 to 1.12, with a mean value of 0.91 {+-} 0.12. For the ring system, the ratio ranges from 0.69 to 1.40, with a mean value of 1.02 {+-} 0.07. For the neutron system, which presents intrinsic larger uncertainties, the ratio ranged from 0.67 to 1.88, with mean value of 1.16 {+-} 0.27. (author)

  15. Quo vadis, personnel monitoring

    International Nuclear Information System (INIS)

    Becker, K.

    1975-01-01

    With the increasing use of nuclear power and radiation sources, the selection of optimum systems for personnel monitoring is becoming a matter of worldwide concern. The present status of personnel dosimetry, sometimes characterized by unstable and inaccurate detectors and oversimplified interpretation of the results, leaves much to be desired. In particular, photographic film, although having certain advantages with regard to economics and information content, undergoes rapid changes in warm and humid climates. Careful sealing reduces, but does not prevent, these problems. The replacement of film by solid-state dosimeters, primarily thermoluminescence dosimeters, is in progress or being considered by an increasing number of institutions and requires a number of decisions concerning the choice of the optimum detector(s), badge design, and evaluation system; organizational matters, such as the desirability of automation and computerized bookkeeping; etc. The change also implies the potential use of such advanced concepts as different detectors and monitoring periods for the large number of low-risk persons and the small number of high-risk radiation workers. (auth)

  16. Smokers’ Views on Personal Carbon Monoxide Monitors, Associated Apps, and Their Use: An Interview and Think-Aloud Study

    Directory of Open Access Journals (Sweden)

    Aleksandra Herbeć

    2018-02-01

    Full Text Available Smartphone-based personal carbon monoxide (CO monitors and associated apps, or “CO Smartphone Systems” (CSSs for short, could enable smokers to independently monitor their smoking and quitting. This study explored views and preferences regarding CSSs and their use among 16 adult, UK-based smokers. First, semi-structured interviews explored participants’ expectations of CSSs. Secondly, a think-aloud study identified participants’ reactions to a personal CO monitor and to existing or prototype apps. Framework Analysis identified five themes: (1 General views, needs, and motivation to use CSSs; (2 Views on the personal CO monitor; (3 Practicalities of CSS use; (4 Desired features in associated apps; and (5 Factors affecting preferences for CSSs and their use. Participants had high expectations of CSSs and their potential to increase motivation. Priority app features included: easy CO testing journeys, relevant and motivating feedback, and recording of contextual data. Appearance and usability of the personal CO monitor, and accuracy and relevance of CO testing were considered important for engagement. Participants differed in their motivation to use and preferences for CSSs features and use, which might have non-trivial impact on evaluation efforts. Personal CO monitors and associated apps may be attractive tools for smokers, but making CSSs easy to use and evaluating these among different groups of smokers may be challenging.

  17. Artificial Neural Network Model for Monitoring Oil Film Regime in Spur Gear Based on Acoustic Emission Data

    Directory of Open Access Journals (Sweden)

    Yasir Hassan Ali

    2015-01-01

    Full Text Available The thickness of an oil film lubricant can contribute to less gear tooth wear and surface failure. The purpose of this research is to use artificial neural network (ANN computational modelling to correlate spur gear data from acoustic emissions, lubricant temperature, and specific film thickness (λ. The approach is using an algorithm to monitor the oil film thickness and to detect which lubrication regime the gearbox is running either hydrodynamic, elastohydrodynamic, or boundary. This monitoring can aid identification of fault development. Feed-forward and recurrent Elman neural network algorithms were used to develop ANN models, which are subjected to training, testing, and validation process. The Levenberg-Marquardt back-propagation algorithm was applied to reduce errors. Log-sigmoid and Purelin were identified as suitable transfer functions for hidden and output nodes. The methods used in this paper shows accurate predictions from ANN and the feed-forward network performance is superior to the Elman neural network.

  18. Monitoring of activity of the persons and vehicles at the exit from the NPP Bohunice

    International Nuclear Information System (INIS)

    Dobis, L.; Kaizer, J.; Svitek, J.

    1998-01-01

    In this paper the technical description of the monitoring of activity of the persons and vehicles at the exit from the NPP Bohunice as well as the results of monitoring during last six months are described

  19. Dose measurement during defectoscopic work using electronic personal dosimeters

    International Nuclear Information System (INIS)

    Smoldasova, J.

    2008-01-01

    Personal monitoring of the external radiation of radiation, personnel exposed to sources of ionizing radiation at a workplace is an important task of the radiological protection. Information based on the measured quantities characterizing the level of the exposure of radiation personnel enable to assess the optimum radiological protection at the relevant workplace and ascertain any deviation from the normal operation in time. Different types of personal dosimeters are used to monitor the external radiation of radiation personnel. Basically, there are two types of dosimeters, passive and active (electronic). Passive dosimeters provide information on the dose of exposure after its evaluation, while electronic dosimeters provide this information instantly. The goal of the work is to compare data acquired during different working activities using the DMC 2000 XB electronic dosimeters and the passive film dosimeters currently used at the defectoscopic workplace. (authors)

  20. Film-Screen Mammography versus digital storage plate mammography: Hard copy and monitor display of microcalcifications and focal findings - A retrospective clinical and histologic analysis

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Wenkel, E.; Aichinger, U.; Tartsch, M.; Kuchar, I.; Bautz, W.

    2003-01-01

    Purpose: A retrospective clinical-histological study to determine the diagnostic accuracy of mammography using conventional screen-film cassettes (hard copy), high-resolution digital phosphor storage plates (hard copy) and monitor display (soft copy) for microcalcifications and focal lesions (BI-RADS TM category 4 or 5). Materials and methods: From April to November 2001, 76 patients underwent conventional film-screen mammography and, after diagnosis and preoperative wire localization, digital mammography with the same exposure parameters. Five investigators retrospectively determined the diagnosis after the operation from randomly distributed mediolateral views (hard-copy reading) and from the monitor display (soft-copy reading). These results were correlated with the final histology. Results: The accuracy of conventional screen-film mammography, digital mammography and monitor-displayed mammography was 67%, 65% and 68% for all findings, (n = 76), 59%, 59% and 68% for microcalcifications (n = 44) and 75%, 72% and 63% for focal lesions (n = 32). The overall results showed no difference. Conclusions: Our findings indicate equivalence of conventional screen-film mammography, high-resolution digital phosphor storage plate mammography and monitor-displayed mammography. (orig.) [de

  1. Mobile Messaging Services-Based Personal Electrocardiogram Monitoring System

    Directory of Open Access Journals (Sweden)

    Ashraf A. Tahat

    2009-01-01

    Full Text Available A mobile monitoring system utilizing Bluetooth and mobile messaging services (MMS/SMSs with low-cost hardware equipment is proposed. A proof of concept prototype has been developed and implemented to enable transmission of an Electrocardiogram (ECG signal and body temperature of a patient, which can be expanded to include other vital signs. Communication between a mobile smart-phone and the ECG and temperature acquisition apparatus is implemented using the popular personal area network standard specification Bluetooth. When utilizing MMS for transmission, the mobile phone plots the received ECG signal and displays the temperature using special application software running on the client mobile phone itself, where the plot can be captured and saved as an image before transmission. Alternatively, SMS can be selected as a transmission means, where in this scenario, dedicated application software is required at the receiving device. The experimental setup can be operated for monitoring from anywhere in the globe covered by a cellular network that offers data services.

  2. Mobile messaging services-based personal electrocardiogram monitoring system.

    Science.gov (United States)

    Tahat, Ashraf A

    2009-01-01

    A mobile monitoring system utilizing Bluetooth and mobile messaging services (MMS/SMSs) with low-cost hardware equipment is proposed. A proof of concept prototype has been developed and implemented to enable transmission of an Electrocardiogram (ECG) signal and body temperature of a patient, which can be expanded to include other vital signs. Communication between a mobile smart-phone and the ECG and temperature acquisition apparatus is implemented using the popular personal area network standard specification Bluetooth. When utilizing MMS for transmission, the mobile phone plots the received ECG signal and displays the temperature using special application software running on the client mobile phone itself, where the plot can be captured and saved as an image before transmission. Alternatively, SMS can be selected as a transmission means, where in this scenario, dedicated application software is required at the receiving device. The experimental setup can be operated for monitoring from anywhere in the globe covered by a cellular network that offers data services.

  3. Online monitoring of oil film using electrical capacitance tomography and level set method

    International Nuclear Information System (INIS)

    Xue, Q.; Ma, M.; Sun, B. Y.; Cui, Z. Q.; Wang, H. X.

    2015-01-01

    In the application of oil-air lubrication system, electrical capacitance tomography (ECT) provides a promising way for monitoring oil film in the pipelines by reconstructing cross sectional oil distributions in real time. While in the case of small diameter pipe and thin oil film, the thickness of the oil film is hard to be observed visually since the interface of oil and air is not obvious in the reconstructed images. And the existence of artifacts in the reconstructions has seriously influenced the effectiveness of image segmentation techniques such as level set method. Besides, level set method is also unavailable for online monitoring due to its low computation speed. To address these problems, a modified level set method is developed: a distance regularized level set evolution formulation is extended to image two-phase flow online using an ECT system, a narrowband image filter is defined to eliminate the influence of artifacts, and considering the continuity of the oil distribution variation, the detected oil-air interface of a former image can be used as the initial contour for the detection of the subsequent frame; thus, the propagation from the initial contour to the boundary can be greatly accelerated, making it possible for real time tracking. To testify the feasibility of the proposed method, an oil-air lubrication facility with 4 mm inner diameter pipe is measured in normal operation using an 8-electrode ECT system. Both simulation and experiment results indicate that the modified level set method is capable of visualizing the oil-air interface accurately online

  4. A study of the NRPB fast neutron personal monitoring service

    International Nuclear Information System (INIS)

    Bartlett, D.T.; Knight, A.; Marshall, T.O.

    1975-10-01

    The NRPB Fast Neutron Personal Monitoring Service has been reviewed and modifications have been, or are being, introduced to improve the accuracy and reliability of the nuclear emulsion dosemeter employed by the Service. This report presents the conclusions of the study. Experimental results of the investigations undertaken in the course of this study, together with full details of the dosemeter and Service, are appended. (author)

  5. Joint hierarchical Gaussian process model with application to personalized prediction in medical monitoring.

    Science.gov (United States)

    Duan, Leo L; Wang, Xia; Clancy, John P; Szczesniak, Rhonda D

    2018-01-01

    A two-level Gaussian process (GP) joint model is proposed to improve personalized prediction of medical monitoring data. The proposed model is applied to jointly analyze multiple longitudinal biomedical outcomes, including continuous measurements and binary outcomes, to achieve better prediction in disease progression. At the population level of the hierarchy, two independent GPs are used to capture the nonlinear trends in both the continuous biomedical marker and the binary outcome, respectively; at the individual level, a third GP, which is shared by the longitudinal measurement model and the longitudinal binary model, induces the correlation between these two model components and strengthens information borrowing across individuals. The proposed model is particularly advantageous in personalized prediction. It is applied to the motivating clinical data on cystic fibrosis disease progression, for which lung function measurements and onset of acute respiratory events are monitored jointly throughout each patient's clinical course. The results from both the simulation studies and the cystic fibrosis data application suggest that the inclusion of the shared individual-level GPs under the joint model framework leads to important improvements in personalized disease progression prediction.

  6. Personnel monitoring

    International Nuclear Information System (INIS)

    1965-01-01

    This film stresses the need for personnel monitoring in work areas where there is a hazard of exposure to radiation. It illustrates the use of personnel monitoring devices (specially the film dosimeter), the assessment of exposure to radiation and the detailed recording of the results on personnel filing cards

  7. Personnel monitoring

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1966-12-31

    This film stresses the need for personnel monitoring in work areas where there is a hazard of exposure to radiation. It illustrates the use of personnel monitoring devices (specially the film dosimeter), the assessment of exposure to radiation and the detailed recording of the results on personnel filing cards

  8. Personal dosimetric monitoring in Ukraine: current status and further development

    International Nuclear Information System (INIS)

    Chumak, V. V.; Musijachenkom, A. V.; Boguslavskaya, A. I.

    2003-01-01

    Presently Ukraine has mixed system for dosimetric monitoring. Nuclear power plants and some major nuclear facilities have their own dosimetry services, which are responsible for regular dosimetric monitoring of workers. Rest of occupationally exposed persons is monitored by dosimetry laboratories affiliated to the territorial authorities for sanitary and epidemiology supervision. In 2002-2003 Ukrainian Ministry of Health performed survey of the status of dosimetric monitoring and inventory of critical groups requiring such monitoring. Dosimetry services in Ukraine cover about 38,000 occupationally exposed workers, including 9,100 medical professionals, 16,400 employees of 5 nuclear power plants and ca.12,400 workers dealing with other sources of occupational exposure (industry, research). Territorial dosimetry services operate in 13 of 24 regions of Ukraine, using DTU-01 manual TLD readers produced with one exception in 1988-1990. The coverage of critical groups by dosimetric monitoring is variable and ranges from 38% to 100% depending on the region. Personnel of nuclear power plants (about 16,400 workers) is monitored by their own dosimetry services achieving absolute coverage of the main staff and temporary workers. Current inadequate status of dosimetric monitoring infrastructure in Ukraine demands an urgent elaboration of the united state system for monitoring and recording of individual doses. The proposed plan would allows to bring dosimetry infrastructure in Ukraine to the modern state which would be compatible with existing and future European and international radiation protection networks. Unitary structure of Ukraine, strong administrative command and good communications between regions of the country are positive factors in favour of efficient implementation of the proposed plan. Deficiencies are associated with limited funding of this effort. (authors)

  9. Comparing different error-conditions in film dosemeter evaluation

    International Nuclear Information System (INIS)

    Roed, H.; Figel, M.

    2007-01-01

    In the evaluation of a film used as a personal dosemeter it may be necessary to mark the dosemeters when possible error-conditions are recognised, such as errors that have an influence on the ability to make a correct evaluation of the dose value. In this project a comparison has been carried out to examine how two individual monitoring services, IMS [National Inst. of Radiation Hygiene (Denmark) (NIRH) and National Research Centre for Environment and Health (Germany) (GSF)], from two different EU countries mark their dosemeters. The IMS are different in size, type of customers and issuing period, but both use films as their primary dosemeters. The error-conditions examined are dosemeters exposed to moisture or light, contaminated dosemeters, films exposed outside the badge, missing filters in the badge, films inserted incorrectly in the badge and dosemeters not returned or returned too late to the IMS. The data are collected for the year 2003 where NIRH evaluated ∼50,000 and GSF ∼1.4 million film dosemeters. The percentage of film dosemeters is calculated for each error-condition as well as the distribution among eight different employee categories, i.e. medicine, nuclear medicine, nuclear industry, industry, radiography, laboratories, veterinary and others. It turned out, that incorrect insertion of the film in the badge was the most common error-condition observed at both IMS and that veterinarians, as the employee category, generally have the highest number of errors. NIRH has a significantly higher relative number of dosemeters in most error-conditions than GSF, which perhaps reflects that a comparison is difficult due to different systemic and methodical differences between the IMS and countries, e.g. regulations and monitoring programs etc. Also the non-existence of a common categorisation method for employee categories contributes to make a comparison like this difficult. (authors)

  10. Real-time monitoring of luminescent lifetime changes of PtOEP oxygen sensing film with LED/photodiode-based time-domain lifetime device.

    Science.gov (United States)

    Ji, Shaomin; Wu, Wanhua; Wu, Yubo; Zhao, Taiyang; Zhou, Fuke; Yang, Yubin; Zhang, Xin; Liang, Xiaofen; Wu, Wenting; Chi, Lina; Wang, Zhonggang; Zhao, Jianzhang

    2009-05-01

    A cost-effective LED/photodiode(PD)-based time-domain luminescent lifetime measuring device with rugged electronics and simplified algorithms was assembled and successfully used to characterize oxygen sensing films, by continuously monitoring phosphorescence lifetime changes of phosphorescent platinum octaethylporphyrin (PtOEP) in cardo poly(aryl ether ketone) polymer (IMPEK-C) vs. variation of the oxygen partial pressure in a gas mixture (O(2)/N(2)). The results determined by both phosphorescence lifetime and intensity monitoring were compared and the lifetime mode gave results which are in good agreement with the intensity mode. The lifetime-based linear Stern-Volmer plot indicates that the PtOEP molecules are nearly homogeneously distributed in the sensing film. The phosphorescent lifetime of the PtOEP film changes from 75 micros in neat N(2) to less than 2 micros in neat O(2). The sensing system (by combination of the PtOEP sensing film with the home-assembled lifetime device) gives a high lifetime-based O(2) sensing resolution, e.g. about 2 micros Torr(-1) for low O(2) concentration (below 3.5% O(2), V/V). This feasible lifetime device configuration is affordable to most sensor laboratories and the device may facilitate the study of O(2) sensing material with the continuous lifetime monitoring method.

  11. Proceedings of the specialist meeting on personal dosimetry and area monitoring suitable for radon and daughter products

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    The programme of work of the OECD Nuclear Energy Agency includes topics relating to radiation and environmental protection matters in mining and milling operations. A first Specialist Meeting on Personal Dosimetry and Area Monitoring suitable for Radon and Daughter Products was organised in October 1976 at Elliot Lake, Canada. The proceedings were published by NEA some months later. Following an enquiry among interested persons, NEA decided to organise a new meeting on the same subject in Paris from 20th to 22nd November 1978. The meeting dealt with questions relating to personal dosimetry techniques, the monitoring of the atmosphere in mines and their neighbourhood, as well as in buildings

  12. 26 CFR 1.992-4 - Coordination with personal holding company provisions in case of certain produced film rents.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 10 2010-04-01 2010-04-01 false Coordination with personal holding company provisions in case of certain produced film rents. 1.992-4 Section 1.992-4 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Domestic International...

  13. Rapid, low cost prototyping of transdermal devices for personal healthcare monitoring

    Directory of Open Access Journals (Sweden)

    Sanjiv Sharma

    2017-04-01

    Full Text Available The next generation of devices for personal healthcare monitoring will comprise molecular sensors to monitor analytes of interest in the skin compartment. Transdermal devices based on microneedles offer an excellent opportunity to explore the dynamics of molecular markers in the interstitial fluid, however good acceptability of these next generation devices will require several technical problems associated with current commercially available wearable sensors to be overcome. These particularly include reliability, comfort and cost. An essential pre-requisite for transdermal molecular sensing devices is that they can be fabricated using scalable technologies which are cost effective.We present here a minimally invasive microneedle array as a continuous monitoring platform technology. Method for scalable fabrication of these structures is presented. The microneedle arrays were characterised mechanically and were shown to penetrate human skin under moderate thumb pressure. They were then functionalised and evaluated as glucose, lactate and theophylline biosensors. The results suggest that this technology can be employed in the measurement of metabolites, therapeutic drugs and biomarkers and could have an important role to play in the management of chronic diseases. Keywords: Microneedles, Minimally invasive sensors, Continuous glucose monitoring (CGM, Continuous lactate monitoring (CLM, Interstitial therapeutic drug monitoring (iTDM

  14. Energy Use and Power Levels in New Monitors and Personal Computers; TOPICAL

    International Nuclear Information System (INIS)

    Roberson, Judy A.; Homan, Gregory K.; Mahajan, Akshay; Nordman, Bruce; Webber, Carrie A.; Brown, Richard E.; McWhinney, Marla; Koomey, Jonathan G.

    2002-01-01

    Our research was conducted in support of the EPA ENERGY STAR Office Equipment program, whose goal is to reduce the amount of electricity consumed by office equipment in the U.S. The most energy-efficient models in each office equipment category are eligible for the ENERGY STAR label, which consumers can use to identify and select efficient products. As the efficiency of each category improves over time, the ENERGY STAR criteria need to be revised accordingly. The purpose of this study was to provide reliable data on the energy consumption of the newest personal computers and monitors that the EPA can use to evaluate revisions to current ENERGY STAR criteria as well as to improve the accuracy of ENERGY STAR program savings estimates. We report the results of measuring the power consumption and power management capabilities of a sample of new monitors and computers. These results will be used to improve estimates of program energy savings and carbon emission reductions, and to inform rev isions of the ENERGY STAR criteria for these products. Our sample consists of 35 monitors and 26 computers manufactured between July 2000 and October 2001; it includes cathode ray tube (CRT) and liquid crystal display (LCD) monitors, Macintosh and Intel-architecture computers, desktop and laptop computers, and integrated computer systems, in which power consumption of the computer and monitor cannot be measured separately. For each machine we measured power consumption when off, on, and in each low-power level. We identify trends in and opportunities to reduce power consumption in new personal computers and monitors. Our results include a trend among monitor manufacturers to provide a single very low low-power level, well below the current ENERGY STAR criteria for sleep power consumption. These very low sleep power results mean that energy consumed when monitors are off or in active use has become more important in terms of contribution to the overall unit energy consumption (UEC

  15. Growth of thin films of TiN on MgO(100) monitored by high-pressure RHEED

    DEFF Research Database (Denmark)

    Pryds, Nini; Cockburn, D.; Rodrigo, Katarzyna Agnieszka

    2008-01-01

    Reflection high-energy electron diffraction (RHEED) operated at high pressure has been used to monitor the initial growth of titanium nitride (TiN) thin films on single-crystal (100) MgO substrates by pulsed laser deposition (PLD). This is the first RHEED study where the growth of TiN films...... electron microscopy. These observations are in good agreement with the three-dimensional Volmer-Weber growth type, by which three-dimensional crystallites are formed and later cause a continuous surface roughening. This leads to an exponential decrease in the intensity of the specular spot in the RHEED...

  16. Commercial Smartphone-Based Devices and Smart Applications for Personalized Healthcare Monitoring and Management.

    Science.gov (United States)

    Vashist, Sandeep Kumar; Schneider, E Marion; Luong, John H T

    2014-08-18

    Smartphone-based devices and applications (SBDAs) with cost effectiveness and remote sensing are the most promising and effective means of delivering mobile healthcare (mHealthcare). Several SBDAs have been commercialized for the personalized monitoring and/or management of basic physiological parameters, such as blood pressure, weight, body analysis, pulse rate, electrocardiograph, blood glucose, blood glucose saturation, sleeping and physical activity. With advances in Bluetooth technology, software, cloud computing and remote sensing, SBDAs provide real-time on-site analysis and telemedicine opportunities in remote areas. This scenario is of utmost importance for developing countries, where the number of smartphone users is about 70% of 6.8 billion cell phone subscribers worldwide with limited access to basic healthcare service. The technology platform facilitates patient-doctor communication and the patients to effectively manage and keep track of their medical conditions. Besides tremendous healthcare cost savings, SBDAs are very critical for the monitoring and effective management of emerging epidemics and food contamination outbreaks. The next decade will witness pioneering advances and increasing applications of SBDAs in this exponentially growing field of mHealthcare. This article provides a critical review of commercial SBDAs that are being widely used for personalized healthcare monitoring and management.

  17. Associations Between Personality Traits and Adherence to Antidepressants Assessed Through Self-Report, Electronic Monitoring, and Pharmacy Dispensing Data: A Pilot Study.

    Science.gov (United States)

    Wouters, Hans; Amin, Darya F H; Taxis, Katja; Heerdink, Eibert R; Egberts, Antoine C G; Gardarsdottir, Helga

    2016-10-01

    Treatment with antidepressants is often compromised by substantial nonadherence. To understand nonadherence, specific medication-related behaviors and beliefs have been studied, but less is known about broader and temporally stable personality "traits." Furthermore, adherence has often been assessed by a single method. Hence, we investigated associations between the Big Five personality traits and adherence assessed by self-report, electronic drug use monitoring, and dispensing data. Using the Big Five Inventory, we assessed the personality traits "openness," "conscientiousness," "extraversion," "agreeableness," and "neuroticism" of patients treated with antidepressants who were invited through community pharmacies. Self-reported adherence was assessed with the Medication Adherence Rating Scale (score >24), electronic monitoring with medication event monitoring system (MEMS) devices (therapy days missed ≤ 10% and personality traits, the third and fourth quartiles of "conscientiousness" were associated with better self-reported adherence (odds ratio, 3.63; 95% confidence interval, 1.34-9.86 and odds ratio, 2.97; 95% confidence interval, 1.09-8.08; P ≤ 0.05). No relationships were found between personality traits and adherence assessed through electronic drug use monitoring or dispensing data. We therefore conclude that adherence to antidepressant therapy seems to be largely unrelated to personality traits.

  18. Vascular and lung function related to ultrafine and fine particles exposure assessed by personal and indoor monitoring: a cross-sectional study

    DEFF Research Database (Denmark)

    Olsen, Yulia; Karottki, Dorina Gabriela; Jensen, Ditte Marie

    2014-01-01

    -related effects. Methods: Associations between vascular and lung function, inflammation markers and exposure in terms of particle number concentration (PNC; d = 10-300 nm) were studied in a cross-sectional design with personal and home indoor monitoring in the Western Copenhagen Area, Denmark. During 48-h, PNC...... and PM2.5 were monitored in living rooms of 60 homes with 81 non-smoking subjects (30-75 years old), 59 of whom carried personal monitors both when at home and away from home. We measured lung function in terms of the FEV1/FVC ratio, microvascular function (MVF) and pulse amplitude by digital artery...... tonometry, blood pressure and biomarkers of inflammation including C-reactive protein, and leukocyte counts with subdivision in neutrophils, eosinophils, monocytes, and lymphocytes in blood. Results: PNC from personal and stationary home monitoring showed weak correlation (r = 0.15, p = 0.24). Personal UFP...

  19. Applicability of near-infrared spectroscopy in the monitoring of film coating and curing process of the prolonged release coated pellets.

    Science.gov (United States)

    Korasa, Klemen; Hudovornik, Grega; Vrečer, Franc

    2016-10-10

    Although process analytical technology (PAT) guidance has been introduced to the pharmaceutical industry just a decade ago, this innovative approach has already become an important part of efficient pharmaceutical development, manufacturing, and quality assurance. PAT tools are especially important in technologically complex operations which require strict control of critical process parameters and have significant effect on final product quality. Manufacturing of prolonged release film coated pellets is definitely one of such processes. The aim of the present work was to study the applicability of the at-line near-infrared spectroscopy (NIR) approach in the monitoring of pellet film coating and curing steps. Film coated pellets were manufactured by coating the active ingredient containing pellets with film coating based on polymethacrylate polymers (Eudragit® RS/RL). The NIR proved as a useful tool for the monitoring of the curing process since it was able to determine the extent of the curing and hence predict drug release rate by using partial least square (PLS) model. However, such approach also showed a number of limitations, such as low reliability and high susceptibility to pellet moisture content, and was thus not able to predict drug release from pellets with high moisture content. On the other hand, the at-line NIR was capable to predict the thickness of Eudragit® RS/RL film coating in a wide range (up to 40μm) with good accuracy even in the pellets with high moisture content. To sum up, high applicability of the at-line NIR in the monitoring of the prolonged release pellets production was demonstrated in the present study. The present findings may contribute to more efficient and reliable PAT solutions in the manufacturing of prolonged release dosage forms. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Professional exposure of medical workers: radiation levels, radiation risk and personal dose monitoring

    International Nuclear Information System (INIS)

    Bai Guang

    2005-01-01

    The application of radiation in the field of medicine is the most active area. Due to the rapid and strong development of intervention radiology at present near 20 years, particularly, the medical workers become a popularize group which most rapid increasing and also receiving the must high of professional exposure dose. Because, inter alias, radiation protection management nag training have not fully follow up, the aware of radioactive protection and appropriate approach have tot fully meet the development and need, the professional exposure dose received by medical workers, especially those being engaged in intervention radiology, are more higher, as well as have not yet fully receiving the complete personal dose monitoring, the medical workers become the population group which should be paid the most attention to. The writer would advice in this paper that all medical workers who being received a professional radiation exposure should pay more attention to the safety and healthy they by is strengthening radiation protection and receiving complete personal dose monitoring. (authors)

  1. METHODS OF STATISTICAL MONITORING OF PROFESSIONAL ORIENTATION WORK OF SOCIAL EDUCATORS IN PERSONAL LEARNING ENVIRONMENTS

    Directory of Open Access Journals (Sweden)

    Oleksandr M. Korniiets

    2012-12-01

    Full Text Available The article deals with the application of social services WEB 2.0 for personal learning environment creation that is used for professional orientation work of social educator. The feedback is must be in personal learning environment for the effective professional orientation work. This feedback can be organized through statistical monitoring. The typical solution for organizing personal learning environment with built-in statistical surveys and statistical data processing is considered in the article. The possibilities of the statistical data collection and processing services on the example of Google Analytics are investigated.

  2. Optimization of mass of plastic scintillator film for flow-cell based tritium monitoring: a Monte Carlo study

    International Nuclear Information System (INIS)

    Roy, Arup Singha; Palani Selvam, T.; Raman, Anand; Raja, V.; Chaudhury, Probal

    2014-01-01

    Over the years, various types of tritium-in-air monitors have been designed and developed based on different principles. Ionization chamber, proportional counter and scintillation detector systems are few among them. A plastic scintillator based, flow-cell type online tritium-in-air monitoring system was developed for online monitoring of tritium in air. The value of the scintillator mass inside the cell-volume, which maximizes the response of the detector system, should be obtained to get maximum efficiency. The present study is aimed to optimize the amount of mass of the plastic scintillator film for the flow-cell based tritium monitoring instrument so that maximum efficiency is achieved. The Monte Carlo based EGSnrc code system has been used for this purpose

  3. Predictors of Horror Film Attendance and Appeal: An Analysis of the Audience for Frightening Films.

    Science.gov (United States)

    Tamborini, Ron; Stiff, James

    1987-01-01

    Analyzes the appeal of horror films. Develops a model that finds that important factors in the horror film's appeal are the audience's desire to experience the satisfying resolutions and to see the destruction usually found in these films and the sensation-seeking personality traits of audience members for these films. (NKA)

  4. Commercial Smartphone-Based Devices and Smart Applications for Personalized Healthcare Monitoring and Management

    Directory of Open Access Journals (Sweden)

    Sandeep Kumar Vashist

    2014-08-01

    Full Text Available Smartphone-based devices and applications (SBDAs with cost effectiveness and remote sensing are the most promising and effective means of delivering mobile healthcare (mHealthcare. Several SBDAs have been commercialized for the personalized monitoring and/or management of basic physiological parameters, such as blood pressure, weight, body analysis, pulse rate, electrocardiograph, blood glucose, blood glucose saturation, sleeping and physical activity. With advances in Bluetooth technology, software, cloud computing and remote sensing, SBDAs provide real-time on-site analysis and telemedicine opportunities in remote areas. This scenario is of utmost importance for developing countries, where the number of smartphone users is about 70% of 6.8 billion cell phone subscribers worldwide with limited access to basic healthcare service. The technology platform facilitates patient-doctor communication and the patients to effectively manage and keep track of their medical conditions. Besides tremendous healthcare cost savings, SBDAs are very critical for the monitoring and effective management of emerging epidemics and food contamination outbreaks. The next decade will witness pioneering advances and increasing applications of SBDAs in this exponentially growing field of mHealthcare. This article provides a critical review of commercial SBDAs that are being widely used for personalized healthcare monitoring and management.

  5. Novel Use of a Noninvasive Hemodynamic Monitor in a Personalized, Active Learning Simulation

    Science.gov (United States)

    Zoller, Jonathan K.; He, Jianghua; Ballew, Angela T.; Orr, Walter N.; Flynn, Brigid C.

    2017-01-01

    The present study furthered the concept of simulation-based medical education by applying a personalized active learning component. We tested this novel approach utilizing a noninvasive hemodynamic monitor with the capability to measure and display in real time numerous hemodynamic parameters in the exercising participant. Changes in medical…

  6. Inter-comparison of personal monitors for nanoparticles exposure at workplaces and in the environment.

    Science.gov (United States)

    Todea, Ana Maria; Beckmann, Stefanie; Kaminski, Heinz; Bard, Delphine; Bau, Sébastien; Clavaguera, Simon; Dahmann, Dirk; Dozol, Hélène; Dziurowitz, Nico; Elihn, Karine; Fierz, Martin; Lidén, Göran; Meyer-Plath, Asmus; Monz, Christian; Neumann, Volker; Pelzer, Johannes; Simonow, Barbara Katrin; Thali, Patrick; Tuinman, Ilse; van der Vleuten, Arjan; Vroomen, Huub; Asbach, Christof

    2017-12-15

    Personal monitors based on unipolar diffusion charging (miniDiSC/DiSCmini, NanoTracer, Partector) can be used to assess the individual exposure to nanoparticles in different environments. The charge acquired by the aerosol particles is nearly proportional to the particle diameter and, by coincidence, also nearly proportional to the alveolar lung-deposited surface area (LDSA), the metric reported by all three instruments. In addition, the miniDiSC/DiSCmini and the NanoTracer report particle number concentration and mean particle size. In view of their use for personal exposure studies, the comparability of these personal monitors was assessed in two measurement campaigns. Altogether 29 different polydisperse test aerosols were generated during the two campaigns, covering a large range of particle sizes, morphologies and concentrations. The data provided by the personal monitors were compared with those obtained from reference instruments: a scanning mobility particle sizer (SMPS) for LDSA and mean particle size and a ultrafine particle counter (UCPC) for number concentration. The results indicated that the LDSA concentrations and the mean particle sizes provided by all investigated instruments in this study were in the order of ±30% of the reference value obtained from the SMPS when the particle sizes of the test aerosols generated were within 20-400nm and the instruments were properly calibrated. Particle size, morphology and concentration did not have a major effect within the aforementioned limits. The comparability of the number concentrations was found to be slightly worse and in the range of ±50% of the reference value obtained from the UCPC. In addition, a minor effect of the particle morphology on the number concentration measurements was observed. The presence of particles >400nm can drastically bias the measurement results of all instruments and all metrics determined. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Radiation monitoring at Pakistan research reactor

    International Nuclear Information System (INIS)

    Ali, A.

    1984-05-01

    Area radiation monitoring is accomplished by using Tracer Lab. radiation monitor. Personnel monitoring is carried out using film badges, TLDs (Thermoluminescent Dosimeters) and pocket dosimeters. For the evaluation of monthly accumulated doses of radiation workers film badges/TLDs and for instantaneous/short term dose measurement in higher radiation zones pocket dosimeters are used in addition to film badge/TLD. Environmental monitoring is necessary to check the PARR operation effect on background radiation level in the vicinity of PINSTECH. (A.B.). 4 refs

  8. Monitoring of Persons at the Exit from Bohunice NPP

    International Nuclear Information System (INIS)

    Kaizer, J.; Svitek, J.

    2001-01-01

    Full text: IAEA defines the principal requirement 'defence in depth' as a multilayer system in its authorised document - International Basic Safety Standards for Protection against Ionising Radiation, Safety Series No. 115. The principle of the multilayer system is: a failure at one zone is compensated or corrected at subsequent zones. The main argument why Bohunice NPP modernised its monitoring system at the exit from NPP was the implementation of the principle 'defence in depth'. Several instruments PM7 (Eberline) equipped with the plastic scintillation detectors had been bought because of the modernisation. The instruments had to be integrated into overall security system NPP without any restriction to the number of passing people. The supplier had to modify the basic instrument operation. NPP required a 'dynamic' monitoring version, this means the operation without stopping of a person within the instrument. After the modification the value of the RDA (Reliable Detectable Activity) of the instruments PM7 was within the interval 9.25-10.4 kBq for 137 Cs (dotted source in the middle of the instrument). RDA for the mix of activation products was 2-3 times lower. In conclusion of our paper the results of the monitoring are presented within tree years as well as a discussion about these results. Maximum values of contaminations measured were very low (several kBq) that represented very low risk from potential exposure. (author)

  9. Efficiency Improvement Opportunities for Personal Computer Monitors. Implications for Market Transformation Programs

    Energy Technology Data Exchange (ETDEWEB)

    Park, Won Young [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Phadke, Amol [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Shah, Nihar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-06-29

    Displays account for a significant portion of electricity consumed in personal computer (PC) use, and global PC monitor shipments are expected to continue to increase. We assess the market trends in the energy efficiency of PC monitors that are likely to occur without any additional policy intervention and estimate that display efficiency will likely improve by over 40% by 2015 compared to today’s technology. We evaluate the cost effectiveness of a key technology which further improves efficiency beyond this level by at least 20% and find that its adoption is cost effective. We assess the potential for further improving efficiency taking into account the recent development of universal serial bus (USB) powered liquid crystal display (LCD) monitors and find that the current technology available and deployed in USB powered monitors has the potential to deeply reduce energy consumption by as much as 50%. We provide insights for policies and programs that can be used to accelerate the adoption of efficient technologies to capture global energy saving potential from PC monitors which we estimate to be 9.2 terawatt-hours [TWh] per year in 2015.

  10. Commentary Variations: Level of Verbalization, Personal Reference, and Phase Relations in Instructional Films on Perceptual-Motor Tasks. Technical Report.

    Science.gov (United States)

    Zuckerman, John V.

    In an experiment to determine the most efficient design for the commentary of an instructional film, special consideration was given to three variables concerned with the construction of commentaries: the level of verbalization (the amount of talk), the personal reference of the narrator, and the phase relationship between the commentary and the…

  11. Statistics of official personal dosimetry and monitoring activities of the period 1994-1995

    International Nuclear Information System (INIS)

    Boerner, E.; Wittmann, A.; Wahl, W.

    1998-01-01

    The measuring laboratory of the GSF in Neuherberg is the largest of the six official supervisory laboratories in Germany. It distributes the officially approved personal dosemeters and is responsible for personal dosimetry monitoring of about 140,000 persons in the German federal states of Bavaria, Hesse, Schleswig-Holstein, and, since 1989, Baden-Wuerttmeberg. Dosemeter readouts are recorded here in a database together with personal data and data describing activities, so that the information collected can be used as a source of reference for establishing general surveys of occupational exposure to external irradiation with ionizing radiation. The report first describes the dosemeter designs and the methods applied by the GSF lab for quality assurance, then explains results of the statistical evaluation of the recent data from 1994-1995, and concludes with explaining tendencies shown by long-term curves of the collective and average annual doses recorded in the years from 1986 until 1995. (orig./CB) [de

  12. An Inexpensive High-Temporal Resolution Electronic Sun Journal for Monitoring Personal Day to Day Sun Exposure Patterns

    Directory of Open Access Journals (Sweden)

    Nathan J. Downs

    2017-11-01

    Full Text Available Exposure to natural sunlight, specifically solar ultraviolet (UV radiation contributes to lifetime risks of skin cancer, eye disease, and diseases associated with vitamin D insufficiency. Improved knowledge of personal sun exposure patterns can inform public health policy; and help target high-risk population groups. Subsequently, an extensive number of studies have been conducted to measure personal solar UV exposure in a variety of settings. Many of these studies, however, use digital or paper-based journals (self-reported volunteer recall, or employ cost prohibitive electronic UV dosimeters (that limit the size of sample populations, to estimate periods of exposure. A cost effective personal electronic sun journal (ESJ built from readily available infrared photodiodes is presented in this research. The ESJ can be used to complement traditional UV dosimeters that measure total biologically effective exposure by providing a time-stamped sun exposure record. The ESJ can be easily attached to clothing and data logged to personal devices (including fitness monitors or smartphones. The ESJ improves upon self-reported exposure recording and is a cost effective high-temporal resolution option for monitoring personal sun exposure behavior in large population studies.

  13. Inter-comparison of personal monitors for nanoparticles exposure at workplaces and in the environment

    NARCIS (Netherlands)

    Todea, A.M.; Beckmann, S.; Kaminski, H.; Bard, D.; Bau, S.; Clavaguera, S.; Dahmann, D.; Dozol, H.; Dziurowitz, N.; Elihn, K.; Fierz, M.; Lidén, G.; Meyer-Plath, A.; Monz, C.; Neumann, V.; Pelzer, J.; Simonow, B.K.; Thali, P.; Tuinman, I.; Vleuten, A. van der; Vroomen, H.; Asbach, C.

    2017-01-01

    Personal monitors based on unipolar diffusion charging (miniDiSC/DiSCmini, NanoTracer, Partector) can be used to assess the individual exposure to nanoparticles in different environments. The charge acquired by the aerosol particles is nearly proportional to the particle diameter and, by

  14. Who Got All of My Personal Data? Enabling Users to Monitor the Proliferation of Shared Personally Identifiable Information

    OpenAIRE

    Labitzke , Sebastian

    2011-01-01

    Part 4: Privacy and Transparency in the Age of Cloud Computing; International audience; The risk involved when users publish information, which becomes available to an unintentional broad audience via online social networks is evident. It is especially difficult for users of social networks to determine who will get the information before it is shared. Moreover, it is impossible to monitor data flows or to control the access to personal data after sharing the information. In contrast to enter...

  15. The personal dosimetry in Mexico; La dosimetria personal en Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, M.A. [Proxtronics/ Asesoria Integral en Dosimetria Termoluminiscente S.A. de C.V., Canal de Miramontes 2030-14, Col. Educacion, 04400 Mexico D.F. (Mexico)]. e-mail: aidtsa@avantel.net

    2006-07-01

    The Personal Dosimetry in Mexico, has an approximately 30 year-old history; and it had been and it is at the moment, one of the more important resources with which the personnel that works with ionizing radiation sources counts for its protection. The Personal Dosimetry begins with the film dosimetry, technique that even continues being used at the present time by some users, and the main reason of its use is for economic reasons. At the moment this technique, it has been surpassed, by the Thermoluminescent dosimetry, which has taken a lot of peak, mainly by the technological development with which it is counted at the present time; what has given as a result that this technique becomes tip technology; that supported in the characteristic of the used materials, as the handling and processing of the information associated with the new PC, digitizer cards, software etc, what has allowed increases it potential. In this work the current necessities of the market are presented as well as an analysis of the future real necessities in Mexico, at national level, the companies that provide this service and that they spread to satisfy this necessity of the market, including the different used technologies are also mentioned. The application ranges, at the same time, of the advantages and disadvantages of the different systems of Personal Dosimetry in the market. The companies that at the moment provide the service of Personal Dosimetry, its use materials and equipment in indistinct form, for the monitoring of gamma radiation, beta particles, different qualities of x-ray radiation, and sometimes neutrons. The monitoring of the exposed personnel at the diverse sources of ionizing radiation mentioned is carried out in many occasions without having with the materials (detectors), neither the appropriate infrastructure and therefore without the quality control that guarantees a correct evaluation of the dose equivalent, as a result of the exposure to the ionizing radiations; it

  16. Fiction Film Dialogue vs Documentary Film Dialogue: Genre Peculiarities of Translation

    Directory of Open Access Journals (Sweden)

    Вера Евгеньевна Горшкова

    2016-12-01

    Full Text Available The article gives an analysis of the film dialogue translation depending on the genre peculiarities of a spoken word medium, i. e. of a fiction film and of a documentary. The latter is traditionally disregarded by linguists and translators due to an established opinion that it lacks an overt literary aesthetic component. Thus it makes a documentary much easier to translate and its text gets closer to the information text the translation dominant of which is to render its information component. The article analyses an universal character of image-sense applied to different cinematographic genres. This thesis is demonstrated with examples from fiction and documentary film dialogues such as The Artist, Il y a longtemps que je t’aime, Espionne pendant la seconde guerre mondiale translated into French and Russian. It is highlighted that particular verbal components/utterances quite often get especially crucial in the context of the film dialogue increasing its poetic function and creating a complete image-sense. Such lexical units as personal pronouns «ты» and «вы» (you as the 2nd person singular in Russian and the 2nd person plural, respectively have no small share in the above process as their adequate translation contributes to the audience's integral perception of the film as an aesthetic phenomenon. It is postulated that a documentary that deals with «the creative elaboration of the reality» has a lot in common with a fiction film in the regard of its compliance with the director's intention, the presentation of the sequence of events and their respective interpretation in the film. In this regard the adequate rendering of the image-sense of a documentary is especially vital in the analysis of events separated in time. That supposition can be backed up by a translation project carried out on the material of the film dialogue translation of the documentary «Espionne pendant la seconde guerre mondiale» from French into Russian.

  17. A novel paradigm for telemedicine using the personal bio-monitor.

    Science.gov (United States)

    Bhatikar, Sanjay R; Mahajan, Roop L; DeGroff, Curt

    2002-01-01

    The foray of solid-state technology in the medical field has yielded an arsenal of sophisticated healthcare tools. Personal, portable computing power coupled with the information superhighway open up the possibility of sophisticated healthcare management that will impact the medical field just as much. The full synergistic potential of three interwoven technologies: (1) compact electronics, (2) World Wide Web, and (3) Artificial Intelligence is yet to be realized. The system presented in this paper integrates these technologies synergistically, providing a new paradigm for healthcare. Our idea is to deploy internet-enabled, intelligent, handheld personal computers for medical diagnosis. The salient features of the 'Personal Bio-Monitor' we envisage are: (1) Utilization of the peripheral signals of the body which may be acquired non-invasively and with ease, for diagnosis of medical conditions; (2) An Artificial Neural Network (ANN) based approach for diagnosis; (3) Configuration of the diagnostic device as a handheld for personal use; (4) Internet connectivity, following the emerging bluetooth protocol, for prompt conveyance of information to a patient's health care provider via the World Wide Web. The proposal is substantiated with an intelligent handheld device developed by the investigators for pediatric cardiac auscultation. This device performed accurate diagnoses of cardiac abnormalities in pediatrics using an artificial neural network to process heart sounds acquired by a low-frequency microphone and transmitted its diagnosis to a desktop PC via infrared. The idea of the personal biomonitor presented here has the potential to streamline healthcare by optimizing two valuable resources: physicians' time and sophisticated equipment time. We show that the elements of such a system are in place, with our prototype. Our novel contribution is the synergistic integration of compact electronics' technology, artificial neural network methodology and the wireless web

  18. Efficiency improvement opportunities for personal computer monitors. Implications for market transformation programs

    Energy Technology Data Exchange (ETDEWEB)

    Park, Won Young; Phadke, Amol; Shah, Nihar [Environmental Energy Technologies Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States)

    2013-08-15

    Displays account for a significant portion of electricity consumed in personal computer (PC) use, and global PC monitor shipments are expected to continue to increase. We assess the market trends in the energy efficiency of PC monitors that are likely to occur without any additional policy intervention and estimate that PC monitor efficiency will likely improve by over 40 % by 2015 with saving potential of 4.5 TWh per year in 2015, compared to today's technology. We discuss various energy-efficiency improvement options and evaluate the cost-effectiveness of three of them, at least one of which improves efficiency by at least 20 % cost effectively beyond the ongoing market trends. We assess the potential for further improving efficiency taking into account the recent development of universal serial bus-powered liquid crystal display monitors and find that the current technology available and deployed in them has the potential to deeply and cost effectively reduce energy consumption by as much as 50 %. We provide insights for policies and programs that can be used to accelerate the adoption of efficient technologies to further capture global energy saving potential from PC monitors which we estimate to be 9.2 TWh per year in 2015.

  19. Indoor, outdoor, and personal exposure monitoring of particulate air pollution: the Baltimore elderly epidemiology-exposure pilot study

    Science.gov (United States)

    Williams, Ron; Creason, John; Zweidinger, Roy; Watts, Randall; Sheldon, Linda; Shy, Carl

    A 17-day pilot study investigating potential PM exposures of an elderly population was conducted near Baltimore, Maryland. Collection of residential indoor, residential outdoor, and ambient monitoring data associated with the subjects living at a common retirement facility was integrated with results from a paired epidemiological pilot study. This integration was used to investigate the potential pathophysiological health effects resulting from daily changes in estimated PM exposures with results reported elsewhere. Objectives of the exposure study were to determine the feasibility of performing PM exposure assessment upon an elderly population and establishing relationships between the various exposure measures including personal monitoring. PM 2.5 was determined to be the dominant outdoor size fraction (0.83 PM 2.5/PM 10 mass ratio by dichot monitoring). Individual 24-h PM 1.5 personal exposures ranged from 12 to 58 μg m -3. Comparison of data from matched sampling dates resulted in mean daily PM 1.5 personal, PM 2.5 outdoor, and PM 1.5 indoor concentrations of 34, 17, and 17 μg m -3, respectively. Activity patterns of the study population indicated a generally sedentary population spending a mean of 96% of each day indoors. Future studies would benefit from the use of a consistent sampling methodology across a larger number of PM measurement sites relevant to the elderly subjects, as well as a larger personal PM exposure study population to more successfully collect data needed in matched epidemiological-exposure studies.

  20. Personal Suicidality in Reception and Identification with Suicidal Film Characters

    Science.gov (United States)

    Till, Benedikt; Vitouch, Peter; Herberth, Arno; Sonneck, Gernot; Niederkrotenthaler, Thomas

    2013-01-01

    The authors investigated the impact of suicidality on identity work during film exposure. Adults with low suicidality ("n" = 150) watched either "It's My Party" or "The Fire Within," censored versions of these films not depicting the suicide, or the control film that concluded with a non-suicidal death. Baseline…

  1. Den danske independent film

    DEFF Research Database (Denmark)

    Hansen, Kim Toft

    2014-01-01

    at producere film, og derved er filmproduktion potentielt gjort tilgængelig for en større gruppe personer som både afsender og modtager. For det fjerde implicerer diskussionen af de to film også genre- og stilmæssige spørgsmål om dansk filmkultur, fordi indiefilmen både i film og uden for filmene italesætter...

  2. Personal neutron monitoring using TLD albedo combined with etched tracks detector

    Energy Technology Data Exchange (ETDEWEB)

    Tsujimura, N.; Momose, T. [Japan Nuclear Cycle Development Institute, Ibarakiken (Japan)

    2002-07-01

    The albedo dosimetry has been carried out in personal neutron monitoring in the MOX fuel plant of JNC Tokai Works, however, it has shortcomings mainly due to the inherently poor energy response. This paper describes our efforts to overcome these difficulties in practical use of albedo dosemeters. The following four subjects are presented: (1) the neutron energy response functions of albedo TLD obtained from the mono-energetic neutron irradiation experiments and the Monte-Carlo calculations, (2) the location- dependent correction factors calculated from the response functions and neutron energy spectra measured in the workplaces, (3) the results of the international personal neutron dosimetry intercomparison program, and (4) the operational comparison program of TLD albedo and etched tracks detector worn by workers engaged in the fabrication process of the MOX fuel plant. Finally, the characteristics of the combination neutron dosemeter using TLD albedo and solid state etched track detector are summarized.

  3. Photovoltaics: tests of thin-film technologies. 6 thin-film technologies in 3 different BIPV modes compared in a real outdoor performance test; PV-ThinFilmTest. 6 thin-film technologies in 3 different BIPV modes compared in a real outdoor performance test

    Energy Technology Data Exchange (ETDEWEB)

    Frei, R.; Meier, Ch.

    2005-07-01

    This final report for the Swiss Federal Office of Energy (SFOE) presents the results of a comparison made between six types of thin-film, building-integrated photovoltaic (BIPV) technologies used in three different modes of building-integration. More than 450 thin-film modules including amorphous silicon and CIS technologies were monitored. Each type of module was installed in three different modes: inclined (20{sup o}), flat with free back air flow, and flat with thermal back insulation. The performance of these commercially available thin-film BIPV systems was monitored using an extensive monitoring program. Additionally, three mono-crystalline PV arrays allowed direct comparison of the technologies. The results of the monitoring work are presented and further work to be done is discussed, including the monitoring of possible long-term degradation.

  4. Mobile personal health records for pregnancy monitoring functionalities: Analysis and potential.

    Science.gov (United States)

    Bachiri, Mariam; Idri, Ali; Fernández-Alemán, José Luis; Toval, Ambrosio

    2016-10-01

    Personal Health Records (PHRs) are a rapidly growing area of health information technology. PHR users are able to manage their own health data and communicate with doctors in order to improve healthcare quality and efficiency. Mobile PHR (mPHR) applications for mobile devices have obtained an interesting market quota since the appearance of more powerful mobile devices. These devices allow users to gain access to applications that used to be available only for personal computers. This paper analyzes the functionalities of mobile PHRs that are specific to pregnancy monitoring. A well-known Systematic Literature Review (SLR) protocol was used in the analysis process. A questionnaire was developed for this task, based on the rigorous study of scientific literature concerning pregnancy and applications available on the market, with 9 data items and 35 quality assessments. The data items contain calendars, pregnancy information, health habits, counters, diaries, mobile features, security, backup, configuration and architectural design. A total of 33 mPHRs for pregnancy monitoring, available for iOS and Android, were selected from Apple App store and Google Play store, respectively. The results show that none of the mPHRs selected met 100% of the functionalities analyzed in this paper. The highest score achieved was 77%, while the lowest was 17%. In this paper, these features are discussed and possible paths for future development of similar applications are proposed, which may lead to a more efficient use of smartphone capabilities. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. The design of a wireless portable device for personalized ultraviolet monitoring

    Science.gov (United States)

    Amini, Navid; Matthews, Jerrid E.; Vahdatpour, Alireza; Sarrafzadeh, Majid

    2009-08-01

    The skin care product market is growing due to the threat of ultraviolet (UV) radiation caused by the destruction of the ozone layer, increasing demand for tanning, and the tendency to wear less clothing. Accordingly, there is a potential demand for a personalized UV monitoring system, which can play a fundamental role in skin cancer prevention by providing measurements of UV radiation intensities and corresponding recommendations. Furthermore, the need for such device becomes more vital since it has turned out that in some places (e.g., on snowy mountains) the UV exposure gets doubled, while individuals are unaware of this fact. This paper highlights the development and initial validation of a wireless and portable embedded system for personalized UV monitoring which is based on a novel software architecture, a high-end UV sensor, and conventional PDA (or a cell phone). In terms of short-term applications, by calculating the UV index, it informs the users about their maximum recommended sun exposure time by taking their skin type and sun protection factor (SPF) of the applied sunscreen into consideration. As for long-term applications, given that the damage caused by UV light is accumulated over days, it is able to keep a record of the amount of UV received over a certain course of time, from a single day to a month. Low energy consumption and high accuracy in estimating the UV index are salient features of this system.

  6. Psycho-social aspects of personal health monitoring: a descriptive literature review.

    Science.gov (United States)

    Muehlan, Holger; Schmidt, Silke

    2013-01-01

    We aimed at providing a short review on already published studies addressing psycho-social issues of personal health monitoring (PHM). Both core questions addressed within this review are: What is the impact of PHM on intended psycho-social and health-related outcomes? And which psycho-social issues affected by or related to PHM have already been investigated? This descriptive review based on a literature search using various databases (Psycinfo, Psyndex, Pubmed, SSCI). Resulting 428 abstracts were coded regarding their psycho-social content. Inspection of results was carried out along the relevance of the papers regarding psycho-social issues. Research in PHM focuses on telemonitoring and smart home applications: Tele-monitoring studies are directed to outcome-related questions, smart home studies to feasibility issues. Despite of technological matters, comparability of both systems in psycho-social issues is lacking. Tele-monitoring has been proven for impact on patient groups with chronic diseases, yet smart home still lacks evidence in health-related and psycho-social matters. Smart home applications have been investigated with respect to attitudes, perceptions and concerns of end-users, telemonitoring regarding acceptance and adherence.

  7. X-ray film digitization using a personal computer and hand-held scanner: a simple technique for storing images

    International Nuclear Information System (INIS)

    Munoz-Nunez, C. F.; Lloret-Alcaniz, A.

    1998-01-01

    To develop a simple, low-cost technique for the digitization of X-ray films for personal use. A 66-MHz 486 PC with 8 MB of RAM, a Logitech ScanMan 256 hand-held scanner and a standard negatoscope with the power source converted to direct current. Although the system was originally designed for the digitization of mammographies, it has also been used with computed tomography, magnetic resonance, digital angiography and ultrasonographic images, as well as plain X-rays. After a minimal training period, the system digitized X-ray films easily and rapidly. Although the scanning values vary depending on the type of image to be digitized, an input spatial resolution of 200 dpi and a contrast resolution of 256 levels of gray are generally adequate. Of the storage formats tested, JPEG presented the best quality/image size ratio. A simple, low-cost technique has been developed for the digitization of X-ray films. This technique enables the storage of images in a digital format, thus facilitating their presentation and transmission. (Author) 9 refs

  8. PhysioDroid: combining wearable health sensors and mobile devices for a ubiquitous, continuous, and personal monitoring.

    Science.gov (United States)

    Banos, Oresti; Villalonga, Claudia; Damas, Miguel; Gloesekoetter, Peter; Pomares, Hector; Rojas, Ignacio

    2014-01-01

    Technological advances on the development of mobile devices, medical sensors, and wireless communication systems support a new generation of unobtrusive, portable, and ubiquitous health monitoring systems for continuous patient assessment and more personalized health care. There exist a growing number of mobile apps in the health domain; however, little contribution has been specifically provided, so far, to operate this kind of apps with wearable physiological sensors. The PhysioDroid, presented in this paper, provides a personalized means to remotely monitor and evaluate users' conditions. The PhysioDroid system provides ubiquitous and continuous vital signs analysis, such as electrocardiogram, heart rate, respiration rate, skin temperature, and body motion, intended to help empower patients and improve clinical understanding. The PhysioDroid is composed of a wearable monitoring device and an Android app providing gathering, storage, and processing features for the physiological sensor data. The versatility of the developed app allows its use for both average users and specialists, and the reduced cost of the PhysioDroid puts it at the reach of most people. Two exemplary use cases for health assessment and sports training are presented to illustrate the capabilities of the PhysioDroid. Next technical steps include generalization to other mobile platforms and health monitoring devices.

  9. Plasma monitoring and PECVD process control in thin film silicon-based solar cell manufacturing

    Directory of Open Access Journals (Sweden)

    Gabriel Onno

    2014-02-01

    Full Text Available A key process in thin film silicon-based solar cell manufacturing is plasma enhanced chemical vapor deposition (PECVD of the active layers. The deposition process can be monitored in situ by plasma diagnostics. Three types of complementary diagnostics, namely optical emission spectroscopy, mass spectrometry and non-linear extended electron dynamics are applied to an industrial-type PECVD reactor. We investigated the influence of substrate and chamber wall temperature and chamber history on the PECVD process. The impact of chamber wall conditioning on the solar cell performance is demonstrated.

  10. A Model-Driven Framework to Develop Personalized Health Monitoring

    Directory of Open Access Journals (Sweden)

    Algimantas Venčkauskas

    2016-07-01

    Full Text Available Both distributed healthcare systems and the Internet of Things (IoT are currently hot topics. The latter is a new computing paradigm to enable advanced capabilities in engineering various applications, including those for healthcare. For such systems, the core social requirement is the privacy/security of the patient information along with the technical requirements (e.g., energy consumption and capabilities for adaptability and personalization. Typically, the functionality of the systems is predefined by the patient’s data collected using sensor networks along with medical instrumentation; then, the data is transferred through the Internet for treatment and decision-making. Therefore, systems creation is indeed challenging. In this paper, we propose a model-driven framework to develop the IoT-based prototype and its reference architecture for personalized health monitoring (PHM applications. The framework contains a multi-layered structure with feature-based modeling and feature model transformations at the top and the application software generation at the bottom. We have validated the framework using available tools and developed an experimental PHM to test some aspects of the functionality of the reference architecture in real time. The main contribution of the paper is the development of the model-driven computational framework with emphasis on the synergistic effect of security and energy issues.

  11. Optical monitoring of surface processes relevant to thin film growth by chemical vapour deposition

    International Nuclear Information System (INIS)

    Simcock, Michael Neil

    2002-01-01

    This thesis reports on the investigation of the use of reflectance anisotropy spectroscopy (RAS) as an in-situ monitor for the preparation and oxidation of GaAs(100) c(4x4) surfaces using a CVD 2000 MOCVD reactor. These surfaces were oxidised using air. It was found that it was possible to follow surface degradation using RA transients at 2.6eV and 4eV. From this data it was possible to speculate on the nature of the surface oxidation process. A study was performed into the rate of surface degradation under different concentrations of air, it was found that the relation between the air concentration and the surface degradation was complicated but that the behaviour of the first third of the degradation approximated a first order behaviour. An estimation of the activation energy of the process was then made, and an assessment of the potential use of the glove-box for STM studies which is an integral part of the MOCVD equipment was also made. Following this, a description is given of the construction of an interferometer for monitoring thin film growth. An investigation is also described into two techniques designed to evaluate the changes in reflected intensity as measured by an interferometer. The first technique uses an iteration procedure to determine the film thickness from the reflection data. This is done using a Taylor series expansion of the thin film reflection function to iterate for the thickness. Problems were found with the iteration when applied to noisy data, these were solved by using a least squares fit to smooth the data. Problems were also found with the iteration at the turning points these were solved using the derivative of the function and by anticipating the position of the turning points. The second procedure uses the virtual interface method to determine the optical constants of the topmost deposited material, the virtual substrate, and the growth rate. This method is applied by using a Taylor series expansion of the thin film reflection

  12. A cost-effective technique for integrating personal radiation dose assessment with personal gravimetric sampling

    International Nuclear Information System (INIS)

    Strydom, R.; Rolle, R.; Van der Linde, A.

    1992-01-01

    During recent years there has been an increasing awareness internationally of radiation levels in the mining and milling of radioactive ores, including those from non-uranium mines. A major aspect of radiation control is concerned with the measurement of radiation levels and the assessment of radiation doses incurred by individual workers. Current techniques available internationally for personnel monitoring of radiation exposures are expensive and there is a particular need to reduce the cost of personal radiation monitoring in South African gold mines because of the large labour force employed. In this regard the obvious benefits of integrating personal radiation monitoring with existing personal monitoring systems already in place in South African gold mines should be exploited. A system which can be utilized for this purpose is personal gravimetric sampling. A new cost-effective technique for personal radiation monitoring, which can be fully integrated with the personal gravimetric sampling strategy being implemented on mines, has been developed in South Africa. The basic principles of this technique and its potential in South African mines are described. 9 refs., 7 figs

  13. Design and application of a web-based real-time personal PM2.5 exposure monitoring system.

    Science.gov (United States)

    Sun, Qinghua; Zhuang, Jia; Du, Yanjun; Xu, Dandan; Li, Tiantian

    2018-06-15

    Growing demand from public health research for conduct large-scale epidemiological studies to explore health effect of PM 2.5 was well-documented. To address this need, we design a web-based real-time personal PM 2.5 exposure monitoring system (RPPM2.5 system) which can help researcher to get big data of personal PM 2.5 exposure with low-cost, low labor requirement, and low operating technical requirements. RPPM2.5 system can provide relative accurate real-time personal exposure data for individuals, researches, and decision maker. And this system has been used in a survey of PM 2.5 personal exposure level conducted in 5 cities of China and has provided mass of valuable data for epidemiological research. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Personal discovery in diabetes self-management: Discovering cause and effect using self-monitoring data.

    Science.gov (United States)

    Mamykina, Lena; Heitkemper, Elizabeth M; Smaldone, Arlene M; Kukafka, Rita; Cole-Lewis, Heather J; Davidson, Patricia G; Mynatt, Elizabeth D; Cassells, Andrea; Tobin, Jonathan N; Hripcsak, George

    2017-12-01

    To outline new design directions for informatics solutions that facilitate personal discovery with self-monitoring data. We investigate this question in the context of chronic disease self-management with the focus on type 2 diabetes. We conducted an observational qualitative study of discovery with personal data among adults attending a diabetes self-management education (DSME) program that utilized a discovery-based curriculum. The study included observations of class sessions, and interviews and focus groups with the educator and attendees of the program (n = 14). The main discovery in diabetes self-management evolved around discovering patterns of association between characteristics of individuals' activities and changes in their blood glucose levels that the participants referred to as "cause and effect". This discovery empowered individuals to actively engage in self-management and provided a desired flexibility in selection of personalized self-management strategies. We show that discovery of cause and effect involves four essential phases: (1) feature selection, (2) hypothesis generation, (3) feature evaluation, and (4) goal specification. Further, we identify opportunities to support discovery at each stage with informatics and data visualization solutions by providing assistance with: (1) active manipulation of collected data (e.g., grouping, filtering and side-by-side inspection), (2) hypotheses formulation (e.g., using natural language statements or constructing visual queries), (3) inference evaluation (e.g., through aggregation and visual comparison, and statistical analysis of associations), and (4) translation of discoveries into actionable goals (e.g., tailored selection from computable knowledge sources of effective diabetes self-management behaviors). The study suggests that discovery of cause and effect in diabetes can be a powerful approach to helping individuals to improve their self-management strategies, and that self-monitoring data can

  15. Respiration and Heartbeat Measurement for Sleep Monitoring Using a Flexible AlN Piezoelectric Film Sensor

    Directory of Open Access Journals (Sweden)

    Nan BU

    2009-11-01

    Full Text Available Respiratory and heartbeat monitoring during sleep provides basic physiological information for diagnosis of sleep disorders. This paper proposes a new method for non-invasive and unconstrained measurement of respiration and heartbeat during sleep. A flexible piezoelectric film sensor made of aluminum nitride (AlN material is used for signal acquisition. The total thickness of this sensor is less than 40 μm; the thin thickness makes it imperceptible when integrated into a bed. In addition, the AlN film sensor has good sensitivity, so that pressure fluctuation due to respiration and heartbeat can be measured when a subject is lying on this sensor. The pressure fluctuation measured can be further separated into signals corresponding to respiration and heartbeat, respectively. In the proposed method, the signal separation is achieved using an algorithm based on empirical mode decomposition (EMD. From the experimental results, it was found that respiration and heartbeat signals can be successfully obtained with the proposed method.

  16. Relaxation in Thin Polymer Films Mapped across the Film Thickness by Astigmatic Single-Molecule Imaging

    KAUST Repository

    Oba, Tatsuya; Vacha, Martin

    2012-01-01

    We have studied relaxation processes in thin supported films of poly(methyl acrylate) at the temperature corresponding to 13 K above the glass transition by monitoring the reorientation of single perylenediimide molecules doped into the films

  17. Personal digital assistants are comparable to traditional diaries for dietary self-monitoring during a weight loss program.

    Science.gov (United States)

    Yon, Bethany A; Johnson, Rachel K; Harvey-Berino, Jean; Gold, Beth Casey; Howard, Alan B

    2007-04-01

    Dietary self-monitoring is considered the core of behavioral weight control programs. As software for personal digital assistants (PDA) has become more available, this study investigated whether the use of a PDA would improve dietary self-monitoring frequency and subsequent weight loss over the use of traditional paper diaries. One-hundred-seventy-six adults (BMI 25-39.9) participated in a 6-month behavioral weight control program. Treatment subjects (n = 61) were provided with a PalmZire 21 with Calorie King's Diet Diary software installed. Their self-monitoring habits and weight loss were compared with the results from a previous program (n = 115) which followed the same protocol using paper diaries for self-monitoring. No significant differences in weight loss or dietary self-monitoring were found. More frequent self-monitoring correlated with weight loss in both groups (pself-monitoring that is fitting to their lifestyle and skills.

  18. Measurement of outdoor radioactivities of radon and thoron by the passive radon-thoron monitor of cup type with cellulose nitrate film

    International Nuclear Information System (INIS)

    Ogawa, Y.; Kimura, Y.; Iida, T.; Yamasaki, K.; Tsujimoto, T.

    1993-01-01

    In order to get information as to effective dose of radon and thoron for the public, we investigated the dosimetry of the average outdoor concentrations of radon and thoron by the cup type radon/thoron monitor using cellulose nitrate film. To overcome the disadvantages of cup monitors which are the relatively low sensitivity and the relatively high detection limit, the present dosimetry is based on the usage of several pairs of cup monitors and the statistical treatments (significant test). Because the detection limit could be lowered using the present dosimetry, we could measure the outdoor concentration levels more precisely. (1 tab.)

  19. Contraceptive efficacy of the personal hormone monitoring system Persona.

    Science.gov (United States)

    Trussell, J

    1999-07-01

    This is a commentary on the contraceptive effectiveness of the personal hormone-monitoring system Persona; it points out the various errors committed in computing method pregnancy rates. The modifications presented by Bonnar et al. on the incorrect procedure for computing method pregnancy rates are criticized as erroneous because the denominator includes cycles in which there is no risk of a method pregnancy according to the authors' algorithm for classifying pregnancy in an imperfect-use cycle. It is also claimed that the new exercise is a more complicated and less accurate way of computing for pregnancy rates by comparison with the simpler alternative. Since this new algorithm, used in the Persona system, is based on flawed logic, the annual risk of pregnancy is actually higher than the estimated 6% among women using Persona and having intercourse in each cycle except on red days.

  20. Fully integrated carbon nanotube composite thin film strain sensors on flexible substrates for structural health monitoring

    Science.gov (United States)

    Burton, A. R.; Lynch, J. P.; Kurata, M.; Law, K. H.

    2017-09-01

    Multifunctional thin film materials have opened many opportunities for novel sensing strategies for structural health monitoring. While past work has established methods of optimizing multifunctional materials to exhibit sensing properties, comparatively less work has focused on their integration into fully functional sensing systems capable of being deployed in the field. This study focuses on the advancement of a scalable fabrication process for the integration of multifunctional thin films into a fully integrated sensing system. This is achieved through the development of an optimized fabrication process that can create a broad range of sensing systems using multifunctional materials. A layer-by-layer deposited multifunctional composite consisting of single walled carbon nanotubes (SWNT) in a polyvinyl alcohol and polysodium-4-styrene sulfonate matrix are incorporated with a lithography process to produce a fully integrated sensing system deposited on a flexible substrate. To illustrate the process, a strain sensing platform consisting of a patterned SWNT-composite thin film as a strain-sensitive element within an amplified Wheatstone bridge sensing circuit is presented. Strain sensing is selected because it presents many of the design and processing challenges that are core to patterning multifunctional thin film materials into sensing systems. Strain sensors fabricated on a flexible polyimide substrate are experimentally tested under cyclic loading using standard four-point bending coupons and a partial-scale steel frame assembly under lateral loading. The study reveals the material process is highly repeatable to produce fully integrated strain sensors with linearity and sensitivity exceeding 0.99 and 5 {{V}}/{ε }, respectively. The thin film strain sensors are robust and are capable of high strain measurements beyond 3000 μ {ε }.

  1. Power levels in office equipment: Measurements of new monitors and personal computers

    International Nuclear Information System (INIS)

    Roberson, Judy A.; Brown, Richard E.; Nordman, Bruce; Webber, Carrie A.; Homan, Gregory H.; Mahajan, Akshay; McWhinney, Marla; Koomey, Jonathan G.

    2002-01-01

    Electronic office equipment has proliferated rapidly over the last twenty years and is projected to continue growing in the future. Efforts to reduce the growth in office equipment energy use have focused on power management to reduce power consumption of electronic devices when not being used for their primary purpose. The EPA ENERGY STAR[registered trademark] program has been instrumental in gaining widespread support for power management in office equipment, and accurate information about the energy used by office equipment in all power levels is important to improving program design and evaluation. This paper presents the results of a field study conducted during 2001 to measure the power levels of new monitors and personal computers. We measured off, on, and low-power levels in about 60 units manufactured since July 2000. The paper summarizes power data collected, explores differences within the sample (e.g., between CRT and LCD monitors), and discusses some issues that arise in m etering office equipment. We also present conclusions to help improve the success of future power management programs.Our findings include a trend among monitor manufacturers to provide a single very low low-power level, and the need to standardize methods for measuring monitor on power, to more accurately estimate the annual energy consumption of office equipment, as well as actual and potential energy savings from power management

  2. Overview of PAT process analysers applicable in monitoring of film coating unit operations for manufacturing of solid oral dosage forms.

    Science.gov (United States)

    Korasa, Klemen; Vrečer, Franc

    2018-01-01

    Over the last two decades, regulatory agencies have demanded better understanding of pharmaceutical products and processes by implementing new technological approaches, such as process analytical technology (PAT). Process analysers present a key PAT tool, which enables effective process monitoring, and thus improved process control of medicinal product manufacturing. Process analysers applicable in pharmaceutical coating unit operations are comprehensibly described in the present article. The review is focused on monitoring of solid oral dosage forms during film coating in two most commonly used coating systems, i.e. pan and fluid bed coaters. Brief theoretical background and critical overview of process analysers used for real-time or near real-time (in-, on-, at- line) monitoring of critical quality attributes of film coated dosage forms are presented. Besides well recognized spectroscopic methods (NIR and Raman spectroscopy), other techniques, which have made a significant breakthrough in recent years, are discussed (terahertz pulsed imaging (TPI), chord length distribution (CLD) analysis, and image analysis). Last part of the review is dedicated to novel techniques with high potential to become valuable PAT tools in the future (optical coherence tomography (OCT), acoustic emission (AE), microwave resonance (MR), and laser induced breakdown spectroscopy (LIBS)). Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Piezoelectric Polymer Films for Application in Monitoring Devices

    Science.gov (United States)

    1977-02-01

    pulse is also evident, as is the decay rate of the pressure, and what appears to be a pronounced " dicrotic notch ," which is asso- ciated with heart valve...investigation of factors responsible for this remark- able behavior of an organic polymer. Commercial PVF 2 homopolymer and copolymer films were oriented by... factors such as changes in elastic modulus of the film with temperature, depolarization processes at the higher temperature, and pyroelectric effects

  4. Personal monitoring services available at Institute for Radiation Protection of ENEA

    International Nuclear Information System (INIS)

    Fantuzzi, E.; Bonarelli, T.

    1999-01-01

    Personnel monitoring provides the means to measure and record the radiation doses received by individual workers. The ionising radiation decree (230/95) set out the circumstances when the assessment and recording of person's exposure is legally required. Many employers issue dosemeters to staff even though there is no legal requirement to do so. This may be part of a quality assurance programme or as a reassurance measure. Dosemeter readings will serve to ensure compliance with legal dose limits and assure the employer that radiation exposure is as low as reasonably achievable. The ENEA (National Agency for New Technology, Energy and the Environment) IRP (Institute for Radiation Protection) individual monitoring service has been running for over 30 years. It offers personnel dosemeters which are based on its expertise and backed up by continual research and development. The report provides details of the dosemeters in use at IRP enable to decide which ones most suit the needs and shows IMS's organisation, customer and communications, dose reports form and administrative items. A short mention of future development will also be given [it

  5. Mammographic microcalcifications: Detection with xerography, screen-film, and digitized film display

    International Nuclear Information System (INIS)

    Smathers, R.L.; Bush, E.; Drace, J.; Stevens, M.; Sommer, F.G.; Brown, B.W.; Karras, B.

    1986-01-01

    Pulverized bone specks and aluminum oxide specks were measured by hand into sizes ranging from 0.2 mm to 1.0 mm and then arranged in clusters. These clusters were superimposed on a human breast tissue phantom, and xeromammograms and screen-film mammograms of the clusters were made. The screen-film mammograms were digitized using a high-resolution laser scanner and then displayed on cathode ray tube (CRT) monitors. Six radiologists independently counted the microcalcifications on the xeromammograms, the screen-film mammograms, and the digitized film mammograms. The xeromammograms were examined with a magnifying glass; the screen-film images were examined with a magnifying glass and by hot light; and the digitized-film images were examined by electronic magnification and image processing. The bone speck size that corresponded to a mean 50% detectability level for each technique was as follows: xeromammography, 0.550 mm; digitized film, 0.573 mm; and screen-film, 0.661 mm. We postulate that electronic magnification and image processing with edge enhancement can improve the capability of screen-film mammography to enhance the detection of microcalcifications

  6. Integrating smart-phone based momentary location tracking with fixed site air quality monitoring for personal exposure assessment.

    Science.gov (United States)

    Su, Jason G; Jerrett, Michael; Meng, Ying-Ying; Pickett, Melissa; Ritz, Beate

    2015-02-15

    Epidemiological studies investigating relationships between environmental exposures from air pollution and health typically use residential addresses as a single point for exposure, while environmental exposures in transit, at work, school or other locations are largely ignored. Personal exposure monitors measure individuals' exposures over time; however, current personal monitors are intrusive and cannot be operated at a large scale over an extended period of time (e.g., for a continuous three months) and can be very costly. In addition, spatial locations typically cannot be identified when only personal monitors are used. In this paper, we piloted a study that applied momentary location tracking services supplied by smart phones to identify an individual's location in space-time for three consecutive months (April 28 to July 28, 2013) using available Wi-Fi networks. Individual exposures in space-time to the traffic-related pollutants Nitrogen Oxides (NOX) were estimated by superimposing an annual mean NOX concentration surface modeled using the Land Use Regression (LUR) modeling technique. Individual's exposures were assigned to stationary (including home, work and other stationary locations) and in-transit (including commute and other travel) locations. For the individual, whose home/work addresses were known and the commute route was fixed, it was found that 95.3% of the time, the individual could be accurately identified in space-time. The ambient concentration estimated at the home location was 21.01 ppb. When indoor/outdoor infiltration, indoor sources of air pollution and time spent outdoors were taken into consideration, the individual's cumulative exposures were 28.59 ppb and 96.49 ppb, assuming a respective indoor/outdoor ratio of 1.33 and 5.00. Integrating momentary location tracking services with fixed-site field monitoring, plus indoor-outdoor air exchange calibration, makes exposure assessment of a very large population over an extended time period

  7. Horror films: tales to master terror or shapers of trauma?

    Science.gov (United States)

    Ballon, Bruce; Leszcz, Molyn

    2007-01-01

    The authors review the literature of cinematic-related psychiatric case reports and report the case of a 22-year-old woman who presented with intrusive thoughts of demonic possession and flashbacks of the film The Exorcist. Cinematic neurosis may be considered a form of psychological crisis shaped by exposure to a film narrative that is emotionally and culturally significant to the individual. The structure of horror films are examined from the perspectives of trauma theory, narrative theory, and borderline personality organization theories, using the film The Exorcist as an example. Within this framework, the horror film can be seen as a cultural tale that provides a mechanism for attempting mastery over anxieties involving issues of separation, loss, autonomy, and identity. An individual will identify with narrative elements that resonate in personal life experiences and cultural factors embedded within the film, which carry levels of either stress that will be mastered, or act as a trauma to the viewer. The outcome of this exposure is related to how the individual's personality structure is organized in combination with the stresses they are experiencing.

  8. Response comparative study of Rn-222 alpha particles track monitors

    International Nuclear Information System (INIS)

    Pereira, Osvaldo Luiz dos Santos

    2010-01-01

    This work was a comparative study between the responses of three monitors, the NRPB, an acrylic monitor (in thin film geometry) and the aluminum monitor (also thin film geometry) in controlled and mixed environment. The experiments consisted on placing the monitors in a plastic tube, with a radio-226 source internal. Only internal CR-39 plastic detectors were analyzed in this work. It was found that the monitors in thin film geometry had activities response of approximately 15% less than the NRPB monitors. All monitors responded the same way when in controlled environment. Related to the type of material, conductive plastic or dielectric (insulator) plastic, the NRPB, in environments without ventilation, responded in the same way. (author)

  9. Quantitative film radiography

    International Nuclear Information System (INIS)

    Devine, G.; Dobie, D.; Fugina, J.; Hernandez, J.; Logan, C.; Mohr, P.; Moss, R.; Schumacher, B.; Updike, E.; Weirup, D.

    1991-01-01

    We have developed a system of quantitative radiography in order to produce quantitative images displaying homogeneity of parts. The materials that we characterize are synthetic composites and may contain important subtle density variations not discernible by examining a raw film x-radiograph. In order to quantitatively interpret film radiographs, it is necessary to digitize, interpret, and display the images. Our integrated system of quantitative radiography displays accurate, high-resolution pseudo-color images in units of density. We characterize approximately 10,000 parts per year in hundreds of different configurations and compositions with this system. This report discusses: the method; film processor monitoring and control; verifying film and processor performance; and correction of scatter effects

  10. Personalized and automated remote monitoring of atrial fibrillation.

    Science.gov (United States)

    Rosier, Arnaud; Mabo, Philippe; Temal, Lynda; Van Hille, Pascal; Dameron, Olivier; Deléger, Louise; Grouin, Cyril; Zweigenbaum, Pierre; Jacques, Julie; Chazard, Emmanuel; Laporte, Laure; Henry, Christine; Burgun, Anita

    2016-03-01

    Remote monitoring of cardiac implantable electronic devices is a growing standard; yet, remote follow-up and management of alerts represents a time-consuming task for physicians or trained staff. This study evaluates an automatic mechanism based on artificial intelligence tools to filter atrial fibrillation (AF) alerts based on their medical significance. We evaluated this method on alerts for AF episodes that occurred in 60 pacemaker recipients. AKENATON prototype workflow includes two steps: natural language-processing algorithms abstract the patient health record to a digital version, then a knowledge-based algorithm based on an applied formal ontology allows to calculate the CHA2DS2-VASc score and evaluate the anticoagulation status of the patient. Each alert is then automatically classified by importance from low to critical, by mimicking medical reasoning. Final classification was compared with human expert analysis by two physicians. A total of 1783 alerts about AF episode >5 min in 60 patients were processed. A 1749 of 1783 alerts (98%) were adequately classified and there were no underestimation of alert importance in the remaining 34 misclassified alerts. This work demonstrates the ability of a pilot system to classify alerts and improves personalized remote monitoring of patients. In particular, our method allows integration of patient medical history with device alert notifications, which is useful both from medical and resource-management perspectives. The system was able to automatically classify the importance of 1783 AF alerts in 60 patients, which resulted in an 84% reduction in notification workload, while preserving patient safety. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  11. Novel use of a noninvasive hemodynamic monitor in a personalized, active learning simulation.

    Science.gov (United States)

    Zoller, Jonathan K; He, Jianghua; Ballew, Angela T; Orr, Walter N; Flynn, Brigid C

    2017-06-01

    The present study furthered the concept of simulation-based medical education by applying a personalized active learning component. We tested this novel approach utilizing a noninvasive hemodynamic monitor with the capability to measure and display in real time numerous hemodynamic parameters in the exercising participant. Changes in medical knowledge concerning physiology were examined with a pre-and posttest. Simply by observation of one's own hemodynamic variables, the understanding of complex physiological concepts was significantly enhanced. Copyright © 2017 the American Physiological Society.

  12. Development of GUI Temperature Monitoring System based on Thin-Film Optical Filter

    Directory of Open Access Journals (Sweden)

    Hilal Adnan Fadhil

    2017-08-01

    Full Text Available Fiber optic sensors have progressed rapidly in recent year as because it has many advantages over other types of sensors in terms of freedom from electromagnetic radiation, wide bandwidth, economy, can withstand high temperature and under harsh environment. Due to those reason a thermo sensor based on fiber optic which utilizes a thin-film optical band-pass filter has been developed. However, the proposed system has advantages over the fiber Bragg grating sensor which can observe the temperature in small area and low transmission loss. The simulation software is used to design a Graphical User Interface (GUI. The GUI system allows the user to monitor the condition and the status of the current temperature. The monitoring system presented in this paper is divided into three basic sub-systems which are retrieve the real-time data system, displaying out the data system, and warning system. This GUI system used to collect the data and process the data for displaying the current data and further checking as a history data has been keep. The values obtained of thermo sensor are measured as 30°C till 330°C and the wavelength values are between 1552.93nm till 1557.25nm

  13. The personal dosimetry in Mexico

    International Nuclear Information System (INIS)

    Salazar, M.A.

    2006-01-01

    The Personal Dosimetry in Mexico, has an approximately 30 year-old history; and it had been and it is at the moment, one of the more important resources with which the personnel that works with ionizing radiation sources counts for its protection. The Personal Dosimetry begins with the film dosimetry, technique that even continues being used at the present time by some users, and the main reason of its use is for economic reasons. At the moment this technique, it has been surpassed, by the Thermoluminescent dosimetry, which has taken a lot of peak, mainly by the technological development with which it is counted at the present time; what has given as a result that this technique becomes tip technology; that supported in the characteristic of the used materials, as the handling and processing of the information associated with the new PC, digitizer cards, software etc, what has allowed increases it potential. In this work the current necessities of the market are presented as well as an analysis of the future real necessities in Mexico, at national level, the companies that provide this service and that they spread to satisfy this necessity of the market, including the different used technologies are also mentioned. The application ranges, at the same time, of the advantages and disadvantages of the different systems of Personal Dosimetry in the market. The companies that at the moment provide the service of Personal Dosimetry, its use materials and equipment in indistinct form, for the monitoring of gamma radiation, beta particles, different qualities of x-ray radiation, and sometimes neutrons. The monitoring of the exposed personnel at the diverse sources of ionizing radiation mentioned is carried out in many occasions without having with the materials (detectors), neither the appropriate infrastructure and therefore without the quality control that guarantees a correct evaluation of the dose equivalent, as a result of the exposure to the ionizing radiations; it

  14. Working conditions analysis according T.L. personal dosimetry results

    International Nuclear Information System (INIS)

    Marinkovic, O.; Jovanovic, S.

    2006-01-01

    Laboratory for personal dosimetry in the Institute of Occupational and Radiological Health, Belgrade, used TLD more than twenty years. Before that, film dosimetry was main method in external monitoring. T.L. dosimetry was started with Reader Toledo 654 and crystals Mg B 4 O 7 . Finally, from 1992 laboratory has Harshaw TLD Reader Model 6600. Dosimeters are crystals LiF type 100, card packed, worn in standard filtrated holders. Personal dosimetry data are keeping 30 years for each worker according to regulations. The data from 1990 are in electronic form. Long experience enables conclusion that new technique means more advantages in practice. Recommendation from this laboratory practice refers to TLD read-out cycle. The longest period should be one month. LiF is recommended crystal. Glow curve deconvolution gives information about chronological irradiation. It is very important to conclude was dosimetry irradiated by 'one-shot' or continuously. Preparing calibration for determination the time since accident laboratory has to define adequate dose calibration methodology including low temperature peaks. Possibility to follow working conditions analyzing TLD glow curve is much more important than low decrease of dose severity. Time depend analyze is not possible if TLD would be read-out more than (approximately) six weeks after irradiation. If ionizing sources produce such low dose and has negligible probability of accidental exposure (according nowadays regulation read-out frequency could be once in three month), the recommendation is not to use external personal monitoring. Reading personal dosimeters once in three months deemed not useful. Complete and successful personal dosimetry dictates using system that enables glow curve shape representation to be sure that signal is ionizing irradiation result or not. Time depend analyze imparts information about protection permanence. In special circumstance, it is possible to estimate the time of exposure. This is extremely

  15. Oxygen diffusion in bilayer polymer films

    DEFF Research Database (Denmark)

    Poulsen, Lars; Zebger, Ingo; Tofte, Jannik Pentti

    2004-01-01

    Experiments to quantify oxygen diffusion have been performed on polymer samples in which a film of poly(ethylene-co-norbornene) was cast onto a film of polystyrene which, in turn, was cast onto an oxygen-impermeable substrate. In the technique employed, the time evolution of oxygen transport...... through the film of poly(ethylene-co-norbornene) and into the polystyrene film was monitored using the phosphorescence of singlet oxygen as a spectroscopic probe. To analyze the data, it was necessary to solve Fick's second law of diffusion for both polymer films. Tractable analytical and numerical...

  16. Personalized professional content recommendation

    Science.gov (United States)

    Xu, Songhua

    2015-10-27

    A personalized content recommendation system includes a client interface configured to automatically monitor a user's information data stream transmitted on the Internet. A hybrid contextual behavioral and collaborative personal interest inference engine resident to a non-transient media generates automatic predictions about the interests of individual users of the system. A database server retains the user's personal interest profile based on a plurality of monitored information. The system also includes a server programmed to filter items in an incoming information stream with the personal interest profile and is further programmed to identify only those items of the incoming information stream that substantially match the personal interest profile.

  17. The design of a miniature personal exposure monitor for continuous real-time data acquisition in electromagnetic field exposure assessment

    International Nuclear Information System (INIS)

    Hansen, N.H.; Conroy, T.J.; Wilson, B.W.

    1994-06-01

    The design of a small, light-weight personal exposure monitor suitable for use in EMF exposure assessment studies is nearing completion at Pacific Northwest Laboratory. The monitor is designed to be non-obtrusive, battery operated, and able to continuously record extremely low-frequency (ELF) (1Ohz--500hz) magnetic-field data. It also captures high-frequency (500hz--1OMhz) transients that exceed a preset threshold, retaining the largest transients in memory. The monitor can record one or more days of data on a single easily replaceable, credit-card-size memory (PCMCIA). A battery charge will last a minimum of one day. Batteries are rechargeable and easily replaced. A data-compression algorithm is under development that will be tailored to the efficient compression of low-frequency EMF signals and will permit data to be logged for at least one day before swapping memory cards. The memory cards are readable by a base- station computer that can perform analysis of the data. The monitor is designed to accommodate four inputs supporting full-field sensors as well as a proposed ocular exposure measurement system. Our design effort has shown that a practical personal exposure monitor for EMF can be built based on current technology, continuous logging of real-time ELF waveforms is both feasible and practical, and such a device is appropriate for proposed EMF exposure studies

  18. Surface Chemistry Interactions of Cationorm with Films by Human Meibum and Tear Film Compounds

    Directory of Open Access Journals (Sweden)

    Georgi As. Georgiev

    2017-07-01

    Full Text Available Cationorm® (CN cationic nanoemulsion was demonstrated to enhance tear film (TF stability in vivo possibly via effects on tear film lipid layer (TFLL. Therefore the interactions of CN with human meibum (MGS and TFLL in vitro and in vivo deserve special study. MGS and CN were spread at the air/water interface of a Langmuir surface balance to ensure a range of MGS/CN oil phase ratios: 20/1, 10/1, 5/1, 3/1, 2/1 and 1/1. The films capability to reorganize during dynamic area changes was evaluated via the surface pressure-area compression isotherms and step/relaxation dilatational rheology studies. Films structure was monitored with Brewster angle microscopy. CN/TFLL interactions at the ocular surface were monitored with non-contact specular microscopy. The in vitro studies of MGS/CN layers showed that (i CN inclusion (at fixed MGS content increased film elasticity and thickness and that (ii CN can compensate for moderate meibum deficiency in MGS/CN films. In vivo CN mixed with TFLL in a manner similar to CN/MGS interactions in vitro, and resulted in enhanced thickness of TFLL. In vitro and in vivo data complement each other and facilitated the study of the composition-structure-function relationship that determines the impact of cationic nanoemulsions on TF.

  19. The system of personal monitoring and the evaluation of occupational exposure to external ionizing radiation in Cuba

    International Nuclear Information System (INIS)

    Molina, Daniel; Castro, Ailza; Martinez, Ernesto; Pernas, Rene

    2008-01-01

    Full text: Personal monitoring of workers is recommended or required by the International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources. In our country the personal monitoring of external exposure to ionizing radiation is carried out by External Dosimetry Laboratory (LDE) of the Center for Radiation Protection and Hygiene (CPHR). We have implemented an individual monitoring service based on thermoluminescence dosimetry system. The service includes whole body and extremity dosimeters. We have two systems; one is base on a manual Toledo TLD reader and the other on an automatic RADOS TLD system. This service is recognized by the National Regulatory Authority in the field of radiation protection and safety. We have implemented a quality assurance (QA) programme designed according to the recommendations of the ISO/IEC 17025 standards. The papers deals with the presentation of these QA programme which includes administrative data and information, technical checking of the equipment, acceptance tests of new dosimeters and equipment, issuing and processing of the dosimeters, dose evaluation, record keeping and reporting, traceability, handling of complaints, internal reviews and external audits. The papers also describe the results of occupational exposure for the different practices during 2006-2007 period. (author)

  20. Design and operation of a 2-D thin-film semiconductor neutron detector array for use as a beamport monitor

    International Nuclear Information System (INIS)

    Unruh, Troy C.; Bellinger, Steven L.; Huddleston, David E.; McNeil, Walter J.; Patterson, Eric; Sobering, Tim J.; McGregor, Douglas S.

    2009-01-01

    Silicon-based diodes coated with a thin film of neutron reactive materials have been shown to produce excellent low-efficiency neutron detectors. This work employs the same technology, but groups 25 equally sized and spaced diodes on a single 29 mm by 29 mm substrate. A 5x5 array was fabricated and coated with a thin film of 6 LiF for use as a low-efficiency neutron beam monitor. The 5x5 neutron detector array is coupled to an array of amplifiers, allowing the response to be interpreted using a LabVIEW FPGA. The 5x5 array has been characterized in a diffracted neutron beam. This work is a part of on-going research to develop various designs of high- and low-efficiency semiconductor neutron detectors.

  1. The intercomparison of 137Cs irradiator output measurement and personal dose equivalent, Hp(10), using TLD and film

    International Nuclear Information System (INIS)

    Nazaroh; Susetyo Trijoko; Sri Inang Sunaryati

    2010-01-01

    Intercomparison of output measurement of 137 Cs irradiator and personal dose equivalent, Hp(10) using TLD and film have been carried out in the year of 2006 to 2008. According to IAEA recommendation, intercomparison is one of audit activities but it is performed in the spirit of collaboration and support rather than in the spirit of inspection. The aim of intercomparison of output measurement of 137 Cs irradiator is to verify the dose stated by the participant laboratories. Intercomparison is also to assess the competency of the participant, to keep traceability and consistency of measurement result, to assure that instrument work correctly and the result of evaluation was in agreement, and also for fulfilling one of the clauses of ISO-17025-2005. Besides that, this intercomparison aimed to facilitate link between the system and members of national measurement and transfer of experience in measurement technique and dose evaluation of radiation. The benefit of intercomparison is important among others as tests of proficiency in dose evaluation or measurement, upgrading quality of service and for obeying supervisor body legislation (BAPETEN). TLD was used as a means of output 137 Cs irradiator measurement, whereas film and TLD were used for dose intercomparison. This paper presented result of intercomparison of output measurement and evaluation of personal dose equivalent, Hp(10) in the year of 2006 to 2008 followed by 6 participants: Balai Pengamanan Fasilitas Kesehatan (BPFK) Jakarta, Medan, Surabaya, Makasar, PTLR and Laboratory of Keselamatan dan Kesehatan Lingkungan (KKL)-PTKMR BATAN. In this intercomparison, the dose of TLD stated by participant were compared with the dose measured by Radiation Metrology Laboratory (LMR), and the results showed the differences were within 10 %, so it was satisfied. The results of intercomparison of personal dose equivalent, Hp(10) were evaluated based on ISO/IEC Guide 43-1, 1997 analysis and expressed as E n . The values of E n

  2. [Personal computer-based computer monitoring system of the anesthesiologist (2-year experience in development and use)].

    Science.gov (United States)

    Buniatian, A A; Sablin, I N; Flerov, E V; Mierbekov, E M; Broĭtman, O G; Shevchenko, V V; Shitikov, I I

    1995-01-01

    Creation of computer monitoring systems (CMS) for operating rooms is one of the most important spheres of personal computer employment in anesthesiology. The authors developed a PC RS/AT-based CMS and effectively used it for more than 2 years. This system permits comprehensive monitoring in cardiosurgical operations by real time processing the values of arterial and central venous pressure, pressure in the pulmonary artery, bioelectrical activity of the brain, and two temperature values. Use of this CMS helped appreciably improve patients' safety during surgery. The possibility to assess brain function by computer monitoring the EEF simultaneously with central hemodynamics and body temperature permit the anesthesiologist to objectively assess the depth of anesthesia and to diagnose cerebral hypoxia. Automated anesthesiological chart issued by the CMS after surgery reliably reflects the patient's status and the measures taken by the anesthesiologist.

  3. Real-time monitoring of human blood clotting using a lateral excited film bulk acoustic resonator

    Science.gov (United States)

    Chen, Da; Wang, Jingjng; Wang, Peng; Guo, Qiuquan; Zhang, Zhen; Ma, Jilong

    2017-04-01

    Frequent assay of hemostatic status is an essential issue for the millions of patients using anticoagulant drugs. In this paper, we presented a micro-fabricated film bulk acoustic sensor for the real-time monitoring of blood clotting and the measurement of hemostatic parameters. The device was made of an Au/ZnO/Si3N4 film stack and excited by a lateral electric field. It operated under a shear mode resonance with the frequency of 1.42 GHz and had a quality factor of 342 in human blood. During the clotting process of blood, the resonant frequency decreased along with the change of blood viscosity and showed an apparent step-ladder curve, revealing the sequential clotting stages. An important hemostatic parameter, prothrombin time, was quantitatively determined from the frequency response for different dilutions of the blood samples. The effect of a typical anticoagulant drug (heparin) on the prothrombin time was exemplarily shown. The proposed sensor displayed a good consistency and clinical comparability with the standard coagulometric methods. Thanks to the availability of direct digital signals, excellent potentials of miniaturization and integration, the proposed sensor has promising application for point-of-care coagulation technologies.

  4. Comparison of Respirable Mass Concentrations Measured by a Personal Dust Monitor and a Personal DataRAM to Gravimetric Measurements.

    Science.gov (United States)

    Halterman, Andrew; Sousan, Sinan; Peters, Thomas M

    2017-12-15

    In 2016, the Mine Safety and Health Administration required the use of continuous monitors to measure respirable dust in mines and better protect miner health. The Personal Dust Monitor, PDM3700, has met stringent performance criteria for this purpose. In a laboratory study, respirable mass concentrations measured with the PDM3700 and a photometer (personal DataRam, pDR-1500) were compared to those measured gravimetrically for five aerosols of varying refractive index and density (diesel exhaust fume, welding fume, coal dust, Arizona road dust (ARD), and salt [NaCl] aerosol) at target concentrations of 0.38, 0.75, and 1.5 mg m-3. For all aerosols except coal dust, strong, near-one-to-one, linear relationships were observed between mass concentrations measured with the PDM3700 and gravimetrically (diesel fume, slope = 0.99, R2 = 0.99; ARD, slope = 0.98, R2 = 0.99; and NaCl, slope = 0.95, R2 = 0.99). The slope deviated substantially from unity for coal dust (slope = 0.55; R2 = 0.99). Linear relationships were also observed between mass concentrations measured with the pDR-1500 and gravimetrically, but one-to-one behavior was not exhibited (diesel fume, slope = 0.23, R2 = 0.76; coal dust, slope = 0.54, R2 = 0.99; ARD, slope = 0.61, R2 = 0.99; NaCl, slope = 1.14, R2 = 0.98). Unlike the pDR-1500, mass concentrations measured with the PDM3700 appear independent of refractive index and density, suggesting that it could have applications in a variety of occupational settings. © The Author(s) 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  5. Comparing personal alpha dosimetry with the conventional area monitoring-time weighting methods of exposure estimation: a Canadian assessment

    International Nuclear Information System (INIS)

    Balint, A.B.; Viljoen, J.

    1988-01-01

    An experimental personal alpha dosimetry program for monitoring exposures of uranium mining facility workers in Canada has been completed. All licenced operating mining facilities were participating. Dosimetry techniques, description of dosimeters used by licences, performance and problems associated with the implementation of the programme as well as technical and administrative advantages and difficulties experienced are discussed. Area monitoring-time weighting methods used and results obtained to determine individual radon and thoron daughter exposure and exposure results generated by using dosimeters are assessed and compared

  6. Accelerometry: A feasible method to monitor physical activity during sub-acute rehabilitation of persons with stroke.

    Science.gov (United States)

    Joseph, Conran; Strömbäck, Björn; Hagströmer, Maria; Conradsson, David

    2018-05-08

    To investigate the feasibility of using accelerometers to monitor physical activity in persons with stroke admitted to inpatient rehabilitation. Longitudinal observational study. Persons with stroke admitted to a specialized rehabilitation centre for sub-acute rehabilitation were recruited between August and December 2016. Volume and intensity of physical activity were assessed with accelerometers throughout the rehabilitation period. Indicators of feasibility included processes (recruitment, protocol adherence and participants' experiences) and scientific feasibility, which assessed the accelerometers' ability to detect change in physical activity among stroke survivors who ambulate independently and those who are dependent on a mobility device. Twenty-seven out of 31 eligible individuals took part in this study, with 23 (85%) completing it. In total, 432 days of rehabilitation were monitored and valid physical activity data were obtained for 408 days (94%). There were no indications that the measurement interfered with participants' ability to participate in rehabilitation. Despite the subjects' ambulation status, the number of steps and time spent in moderate-to-vigorous physical activity increased significantly across the first 18 days of rehabilitation, whereas sedentary time was unchanged. This study supports the feasibility of using accelerometers to capture physical activity behaviour in survivors of stroke during inpatient rehabilitation.

  7. The image database management system of teaching file using personal computer

    International Nuclear Information System (INIS)

    Shin, M. J.; Kim, G. W.; Chun, T. J.; Ahn, W. H.; Baik, S. K.; Choi, H. Y.; Kim, B. G.

    1995-01-01

    For the systemic management and easy using of teaching file in radiology department, the authors tried to do the setup of a database management system of teaching file using personal computer. We used a personal computer (IBM PC compatible, 486DX2) including a image capture card(Window vision, Dooin Elect, Seoul, Korea) and video camera recorder (8mm, CCD-TR105, Sony, Tokyo, Japan) for the acquisition and storage of images. We developed the database program by using Foxpro for Window 2.6(Microsoft, Seattle, USA) executed in the Window 3.1 (Microsoft, Seattle, USA). Each datum consisted of hospital number, name, sex, age, examination date, keyword, radiologic examination modalities, final diagnosis, radiologic findings, references and representative images. The images were acquired and stored as bitmap format (8 bitmap, 540 X 390 ∼ 545 X 414, 256 gray scale) and displayed on the 17 inch-flat monitor(1024 X 768, Samtron, Seoul, Korea). Without special devices, the images acquisition and storage could be done on the reading viewbox, simply. The image quality on the computer's monitor was less than the one of original film on the viewbox, but generally the characteristics of each lesions could be differentiated. Easy retrieval of data was possible for the purpose of teaching file system. Without high cost appliances, we could consummate the image database system of teaching file using personal computer with relatively inexpensive method

  8. Evaluation of personal dose equivalent 'HP(d)' in a external individual monitoring system for X and gamma radiation

    International Nuclear Information System (INIS)

    Santoro, C.; Antonio Filho, J.; Santos, M.A.P.

    2007-01-01

    The good of individual monitoring for external radiation is the assessment of occupational exposure from X and γ radiations in order to assure that the radiological conditions of the workplace are acceptable, safe and satisfactory. The evaluation of radiations doses for workers must not exceed dose limits specified for workers, according to national regulatory agencies. Nowadays, there are two external monitoring systems in use, both based on ICRU definitions. In the conventional system, the workers doses are evaluated in terms of Hx. The personal dosimeter is worn over chest surface and it is calibrated in function of air kerma. In the new system, the workers doses are evaluated in terms of HP(d) and the personal dosimeter is calibrated in function of phantom doses. The aim of this paper is to adapt an external dosimetry laboratory (based on photographic dosimetry) to evaluate the personal dosimeters in terms of HP(d). In this way, a simple methodology, based on linear programming, was utilized. In this adaptation, calibration curves were obtained for radiation qualities (W and N series) described by International Organization for Standardization (ISO 4037-1, 1995). These calibration curves offer a better accuracy on dose determinations and energy below 140 keV, improving the quality of service rendered the society. (author)

  9. Quality assurance in personal dosimetry of external radiation: present situation and future needs

    International Nuclear Information System (INIS)

    Ma, N.

    2006-01-01

    Whole body personal dosimetry is well established for the individual monitoring of radiation workers. High quality radiation dosimetry is essential for workers who rely upon personal dosemeters to record the amount of radiation to which they are exposed. The mandate has been given to the Personal Dosimetry, (secondary standard dosimetry laboratories) S.S.D.L., (Malaysian institute for nuclear energy research) M.I.N.T. to assure the individual monitoring for radiation workers in Malaysia. In 2005, the S.S.D.L;-M.I.N.T. supply, process and read out of personal dosemeters of nearly 13,000 dosimeters monthly, whereby. 12,000 are films and 1,000 are T.L.D.s. The objective of individual monitoring is not limited to the measurement of doses delivered to individuals, but it should demonstrate that limits of exposure have not been exceeded and that working conditions have not unexpectedly deteriorated. Dosimetry measurements are an important component of radiation protection programs and must be of high quality. The exposure of workers to radiation must be controlled and monitored in order to comply with regulatory requirements. S.S.D.L.-M.I.N.T; demonstrates that its performance is at an acceptable level by implementing overall system performance, as evidenced by the ISO 9001 certification of the Personal Dosimetry Service in 2002 and ISO/I.E.C. 17025 accreditation to the calibration laboratory in 2004. The certification and accreditation processes achieved the goal by formalizing the recognition of satisfactory performance, and providing evidence of this performance. Overall performances are assessed, personnel operating the system will be trained and are well qualified and all actions will be documented. The paper describes the overview of the Q.M.S. carried out at the S.S. D.L.-M.I.N.T.. During the implementation of Q.M.S. a few areas has been identified for future consideration. These include performance specification and type testing of dosemeters, which provide a

  10. Review of personal monitoring techniques for the measurement of absorbed dose from external beta and low energy photon radiation

    DEFF Research Database (Denmark)

    Christensen, Poul

    1986-01-01

    The techniques available at present for personal monitoring of doses from external beta and low energy photon radiation are reviewed. The performance of currently used dosimetry systems is compared with that recommended internationally, and developments for improving the actual performance...

  11. The modulating effect of personality traits on neural error monitoring: evidence from event-related FMRI.

    Science.gov (United States)

    Sosic-Vasic, Zrinka; Ulrich, Martin; Ruchsow, Martin; Vasic, Nenad; Grön, Georg

    2012-01-01

    The present study investigated the association between traits of the Five Factor Model of Personality (Neuroticism, Extraversion, Openness for Experiences, Agreeableness, and Conscientiousness) and neural correlates of error monitoring obtained from a combined Eriksen-Flanker-Go/NoGo task during event-related functional magnetic resonance imaging in 27 healthy subjects. Individual expressions of personality traits were measured using the NEO-PI-R questionnaire. Conscientiousness correlated positively with error signaling in the left inferior frontal gyrus and adjacent anterior insula (IFG/aI). A second strong positive correlation was observed in the anterior cingulate gyrus (ACC). Neuroticism was negatively correlated with error signaling in the inferior frontal cortex possibly reflecting the negative inter-correlation between both scales observed on the behavioral level. Under present statistical thresholds no significant results were obtained for remaining scales. Aligning the personality trait of Conscientiousness with task accomplishment striving behavior the correlation in the left IFG/aI possibly reflects an inter-individually different involvement whenever task-set related memory representations are violated by the occurrence of errors. The strong correlations in the ACC may indicate that more conscientious subjects were stronger affected by these violations of a given task-set expressed by individually different, negatively valenced signals conveyed by the ACC upon occurrence of an error. Present results illustrate that for predicting individual responses to errors underlying personality traits should be taken into account and also lend external validity to the personality trait approach suggesting that personality constructs do reflect more than mere descriptive taxonomies.

  12. The modulating effect of personality traits on neural error monitoring: evidence from event-related FMRI.

    Directory of Open Access Journals (Sweden)

    Zrinka Sosic-Vasic

    Full Text Available The present study investigated the association between traits of the Five Factor Model of Personality (Neuroticism, Extraversion, Openness for Experiences, Agreeableness, and Conscientiousness and neural correlates of error monitoring obtained from a combined Eriksen-Flanker-Go/NoGo task during event-related functional magnetic resonance imaging in 27 healthy subjects. Individual expressions of personality traits were measured using the NEO-PI-R questionnaire. Conscientiousness correlated positively with error signaling in the left inferior frontal gyrus and adjacent anterior insula (IFG/aI. A second strong positive correlation was observed in the anterior cingulate gyrus (ACC. Neuroticism was negatively correlated with error signaling in the inferior frontal cortex possibly reflecting the negative inter-correlation between both scales observed on the behavioral level. Under present statistical thresholds no significant results were obtained for remaining scales. Aligning the personality trait of Conscientiousness with task accomplishment striving behavior the correlation in the left IFG/aI possibly reflects an inter-individually different involvement whenever task-set related memory representations are violated by the occurrence of errors. The strong correlations in the ACC may indicate that more conscientious subjects were stronger affected by these violations of a given task-set expressed by individually different, negatively valenced signals conveyed by the ACC upon occurrence of an error. Present results illustrate that for predicting individual responses to errors underlying personality traits should be taken into account and also lend external validity to the personality trait approach suggesting that personality constructs do reflect more than mere descriptive taxonomies.

  13. Neurophysiological evidence of impaired self-monitoring in schizotypal personality disorder and its reversal by dopaminergic antagonism

    OpenAIRE

    Mireia Rabella; Eva Grasa; Iluminada Corripio; Sergio Romero; Miquel Àngel Mañanas; Rosa Mª. Antonijoan; Thomas F. Münte; Víctor Pérez; Jordi Riba

    2016-01-01

    BACKGROUND: Schizotypal personality disorder (SPD) is a schizophrenia-spectrum disorder characterized by odd or bizarre behavior, strange speech, magical thinking, unusual perceptual experiences, and social anhedonia. Schizophrenia proper has been associated with anomalies in dopaminergic neurotransmission and deficits in neurophysiological markers of self-monitoring, such as low amplitude in cognitive event-related brain potentials (ERPs) like the error-related negativity (ERN), and the erro...

  14. Calibration of radiation monitoring instruments

    International Nuclear Information System (INIS)

    1973-01-01

    Radiation protection is dependent on good radiation monitoring, and properly calibrated instruments are essential for this work. Simple procedures for periodically checking and recalibrating different kinds of radiation monitoring instruments are shown in this training film

  15. Calibration of radiation monitoring instruments

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1974-12-31

    Radiation protection is dependent on good radiation monitoring, and properly calibrated instruments are essential for this work. Simple procedures for periodically checking and recalibrating different kinds of radiation monitoring instruments are shown in this training film

  16. Trends in monitoring pharmaceuticals and personal-care products in the aquatic environment by use of passive sampling devices

    Science.gov (United States)

    Mills, G.A.; Vrana, B.; Allan, I.; Alvarez, D.A.; Huckins, J.N.; Greenwood, R.

    2007-01-01

    The use of passive sampling in monitoring pharmaceuticals and personal-care products (PPCPs) in the aquatic environment is discussed. The utility of passive sampling methods for monitoring the fraction of heavy metals and the biologically available fraction of non-polar organic priority pollutants is recognized and these technologies are being used in surveys of water quality. These devices are used to measure the dissolved fraction and they can yield information that can be used in the development of risk assessments models. These devices can also be used to locate illegal dumping and to monitor specific sources of input of PPCPs into the environment, or to monitor the effectiveness of water treatment processes in the removal of these compounds from wastewater. These devices can provide representative information at low cost which necessitate a combination of laboratory calibration and field studies for emerging pollutants.

  17. Radiation exposure by monitors and effects of whistling sound on hearing at workplaces in TV and film production sectors

    International Nuclear Information System (INIS)

    Strasser, H.

    1988-01-01

    Information transmission by means of VDUs, spreading at present rapidly in office work and some branches of the industrial production, is not only an auxiliary means but the essential destination and objective of working activities in specific areas of the media sector. By the progression of the video technique a further concentration of VDT work and the increasing gravity of all advantages and disadvantages is to be expected in the film and TV sectors. The real radiation exposure of the technical staff involved in working with and at monitors and potential risks of hearing by whistling sounds sent out by these apparatuses are analysed and evaluated. Experiences in health hazards by radiation from VDUs in office work had to be adapted adequately to the specific working conditions at work places in film and TV productions. (orig./HP) [de

  18. Monitoring personal budgets and restrictions

    NARCIS (Netherlands)

    Ab van der Torre; Ingrid Ooms; Mirjam de Klerk

    2013-01-01

    The personal budget is a sum of money which recipients can use to arrange and pay for their own care provider. Since its introduction, demand for this provision, which is funded through the Exceptional Medical Expenses Act (AWBZ) has grown rapidly, prompting the Dutch government to take a number

  19. Oromucosal film preparations : points to consider for patient centricity and manufacturing processes

    NARCIS (Netherlands)

    Krampe, Raphael; Visser, Caroline; Frijlink, Henderik W; Breitkreutz, Jörg; Woerdenbag, Herman J; Preis, Maren

    2016-01-01

    INTRODUCTION: According to the European Pharmacopoeia, oromucosal films comprise mucoadhesive buccal films and orodispersible films. Both oral dosage forms receive considerable interest in the recent years as commercially available pharmaceutical products and as small scale personalized

  20. Surface analysis monitoring of polyelectrolyte deposition on Ba0.5Sr0.5TiO3 thin films

    International Nuclear Information System (INIS)

    Morales-Cruz, Angel L.; Fachini, Estevao R.; Miranda, Felix A.; Cabrera, Carlos R.

    2007-01-01

    Thin films are currently gaining interest in many areas such as integrated optics, sensors, friction, reducing coatings, surface orientation layers, and general industrial applications. Recently, molecular self-assembling techniques have been applied for thin film deposition of electrically conducting polymers, conjugated polymers for light-emitting devices, nanoparticles, and noncentrosymmetric-ordered second order nonlinear optical (NOL) devices. Polyelectrolytes self-assemblies have been used to prepare thin films. The alternate immersion of a charged surface in polyannion and a polycation solution leads usually to the formation of films known as polyelectrolyte multilayers. These polyanion and polycation structures are not neutral. However, charge compensation appears on the surface. This constitutes the building driving force of the polyelectrolyte multilayer films. The present approach consists of two parts: (a) the chemisorption of 11-mercaptoundecylamine (MUA) to construct a self-assembled monolayer with the consequent protonation of the amine, and (b) the deposition of opposite charged polyelectrolytes in a sandwich fashion. The approach has the advantage that ionic attraction between opposite charges is the driving force for the multilayer buildup. For our purposes, the multilayer of polyelectrolytes depends on the quality of the surface needed for the application. In many cases, this approach will be used in a way that the roughness factor defects will be diminished. The polyelectrolytes selected for the study were: polystyrene sulfonate sodium salt (PSS), poly vinylsulfate potassium salt (PVS), and polyallylamine hydrochloride (PAH), as shown in . The deposition of polyelectrolytes was carried out by a dipping procedure with the corresponding polyelectrolyte. Monitoring of the alternate deposition of polyelectrolyte bilayers was done by surface analysis techniques such as X-ray photoelectron spectroscopy (XPS), specular reflectance infrared (IR), and

  1. Development of computational models for the simulation of isodose curves on dosimetry films generated by iodine-125 brachytherapy seeds

    International Nuclear Information System (INIS)

    Santos, Adriano M.; Meira-Belo, Luiz C.; Reis, Sergio C.; Grynberg, Suely E.

    2011-01-01

    The interstitial brachytherapy is one modality of radiotherapy in which radioactive sources are placed directly in the region to be treated or close to it. The seeds that are used in the treatment of prostate cancer are generally cylindrical radioactive sources, consisting of a ceramic or metal matrix, which acts as the carrier of the radionuclide and as the X-ray marker, encapsulated in a sealed titanium tube. This study aimed to develop a computational model to reproduce the film-seed geometry, in order to obtain the spatial regions of the isodose curves produced by the seed when it is put over the film surface. The seed modeled in this work was the OncoSeed 6711, a sealed source of iodine-125, which its isodose curves were obtained experimentally in previous work with the use of dosimetric films. For the films modeling, compositions and densities of the two types of dosimetric films were used: Agfa Personal Monitoring photographic film 2/10, manufactured by Agfa-Geavaert; and the model EBT radiochromic film, by International Specialty Products. The film-seed models were coupled to the Monte Carlo code MCNP5. The results obtained by simulations showed to be in good agreement with experimental results performed in a previous work. This indicates that the computational model can be used in future studies for other seeds models. (author)

  2. Development of computational models for the simulation of isodose curves on dosimetry films generated by iodine-125 brachytherapy seeds

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Adriano M.; Meira-Belo, Luiz C.; Reis, Sergio C.; Grynberg, Suely E., E-mail: amsantos@cdtn.b [Center for Development of Nuclear Technology (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-07-01

    The interstitial brachytherapy is one modality of radiotherapy in which radioactive sources are placed directly in the region to be treated or close to it. The seeds that are used in the treatment of prostate cancer are generally cylindrical radioactive sources, consisting of a ceramic or metal matrix, which acts as the carrier of the radionuclide and as the X-ray marker, encapsulated in a sealed titanium tube. This study aimed to develop a computational model to reproduce the film-seed geometry, in order to obtain the spatial regions of the isodose curves produced by the seed when it is put over the film surface. The seed modeled in this work was the OncoSeed 6711, a sealed source of iodine-125, which its isodose curves were obtained experimentally in previous work with the use of dosimetric films. For the films modeling, compositions and densities of the two types of dosimetric films were used: Agfa Personal Monitoring photographic film 2/10, manufactured by Agfa-Geavaert; and the model EBT radiochromic film, by International Specialty Products. The film-seed models were coupled to the Monte Carlo code MCNP5. The results obtained by simulations showed to be in good agreement with experimental results performed in a previous work. This indicates that the computational model can be used in future studies for other seeds models. (author)

  3. Personalized Feedback on Staff Dose in Fluoroscopy-Guided Interventions: A New Era in Radiation Dose Monitoring.

    Science.gov (United States)

    Sailer, Anna M; Vergoossen, Laura; Paulis, Leonie; van Zwam, Willem H; Das, Marco; Wildberger, Joachim E; Jeukens, Cécile R L P N

    2017-11-01

    Radiation safety and protection are a key component of fluoroscopy-guided interventions. We hypothesize that providing weekly personal dose feedback will increase radiation awareness and ultimately will lead to optimized behavior. Therefore, we designed and implemented a personalized feedback of procedure and personal doses for medical staff involved in fluoroscopy-guided interventions. Medical staff (physicians and technicians, n = 27) involved in fluoroscopy-guided interventions were equipped with electronic personal dose meters (PDMs). Procedure dose data including the dose area product and effective doses from PDMs were prospectively monitored for each consecutive procedure over an 8-month period (n = 1082). A personalized feedback form was designed displaying for each staff individually the personal dose per procedure, as well as relative and cumulative doses. This study consisted of two phases: (1) 1-5th months: Staff did not receive feedback (n = 701) and (2) 6-8th months: Staff received weekly individual dose feedback (n = 381). An anonymous evaluation was performed on the feedback and occupational dose. Personalized feedback was scored valuable by 76% of the staff and increased radiation dose awareness for 71%. 57 and 52% reported an increased feeling of occupational safety and changing their behavior because of personalized feedback, respectively. For technicians, the normalized dose was significantly lower in the feedback phase compared to the prefeedback phase: [median (IQR) normalized dose (phase 1) 0.12 (0.04-0.50) µSv/Gy cm 2 versus (phase 2) 0.08 (0.02-0.24) µSv/Gy cm 2 , p = 0.002]. Personalized dose feedback increases radiation awareness and safety and can be provided to staff involved in fluoroscopy-guided interventions.

  4. "Insensitive" to touch: fabric-supported lubricant-swollen polymeric films for omniphobic personal protective gear.

    Science.gov (United States)

    Damle, Viraj G; Tummala, Abhishiktha; Chandrashekar, Sriram; Kido, Cassidee; Roopesh, Ajay; Sun, Xiaoda; Doudrick, Kyle; Chinn, Jeff; Lee, James R; Burgin, Timothy P; Rykaczewski, Konrad

    2015-02-25

    The use of personal protective gear made from omniphobic materials that easily shed drops of all sizes could provide enhanced protection from direct exposure to most liquid-phase biological and chemical hazards and facilitate the postexposure decontamination of the gear. In recent literature, lubricated nanostructured fabrics are seen as attractive candidates for personal protective gear due to their omniphobic and self-healing characteristics. However, the ability of these lubricated fabrics to shed low surface tension liquids after physical contact with other objects in the surrounding, which is critical in demanding healthcare and military field operations, has not been investigated. In this work, we investigate the depletion of oil from lubricated fabrics in contact with highly absorbing porous media and the resulting changes in the wetting characteristics of the fabrics by representative low and high surface tension liquids. In particular, we quantify the loss of the lubricant and the dynamic contact angles of water and ethanol on lubricated fabrics upon repeated pressurized contact with highly absorbent cellulose-fiber wipes at different time intervals. We demonstrate that, in contrast to hydrophobic nanoparticle coated microfibers, fabrics encapsulated within a polymer that swells with the lubricant retain the majority of the oil and are capable of repelling high as well as low surface tension liquids even upon multiple contacts with the highly absorbing wipes. The fabric supported lubricant-swollen polymeric films introduced here, therefore, could provide durable and easy to decontaminate protection against hazardous biological and chemical liquids.

  5. Sensitometric control of roentgen film processors

    International Nuclear Information System (INIS)

    Forsberg, H.; Karolinska Sjukhuset, Stockholm

    1987-01-01

    Monitoring of film processors performance is essential since image quality, patient dose and costs are influenced by the performance. A system for sensitometric constancy control of film processors and their associated components is described. Experience with the system for 3 years is given when implemented on 17 film processors. Modern high quality film processors have a stability that makes a test frequency of once a week sufficient to maintain adequate image quality. The test system is so sensitive that corrective actions almost invariably have been taken before any technical problem degraded the image quality to a visible degree. (orig.)

  6. Glycerin-Induced Conformational Changes in Bombyx mori Silk Fibroin Film Monitored by (13)C CP/MAS NMR and ¹H DQMAS NMR.

    Science.gov (United States)

    Asakura, Tetsuo; Endo, Masanori; Hirayama, Misaki; Arai, Hiroki; Aoki, Akihiro; Tasei, Yugo

    2016-09-09

    In order to improve the stiff and brittle characteristics of pure Bombyx mori (B. mori) silk fibroin (SF) film in the dry state, glycerin (Glyc) has been used as a plasticizer. However, there have been very limited studies on the structural characterization of the Glyc-blended SF film. In this study, (13)C Cross Polarization/Magic Angle Spinning nuclear magnetic resonance (CP/MAS NMR) was used to monitor the conformational changes in the films by changing the Glyc concentration. The presence of only 5 wt % Glyc in the film induced a significant conformational change in SF where Silk I* (repeated type II β-turn and no α-helix) newly appeared. Upon further increase in Glyc concentration, the percentage of Silk I* increased linearly up to 9 wt % Glyc and then tended to be almost constant (30%). This value (30%) was the same as the fraction of Ala residue within the Silk I* form out of all Ala residues of SF present in B. mori mature silkworm. The ¹H DQMAS NMR spectra of Glyc-blended SF films confirmed the appearance of Silk I* in the Glyc-blended SF film. A structural model of Glyc-SF complex including the Silk I* form was proposed with the guidance of the Molecular Dynamics (MD) simulation using ¹H-¹H distance constraints obtained from the ¹H Double-Quantum Magic Angle Spinning (DQMAS) NMR spectra.

  7. Internal exposure monitoring of personnel of a nuclear power plant with pressurized-water reactors

    International Nuclear Information System (INIS)

    Krueger, F.W.; Poulheim, K.F.; Rueger, G.; Schreiter, W.D.

    1982-01-01

    In the GDR a programme for monitoring the internal radiation exposure of personnel has been established in the Bruno Leuschner Nuclear Power Plant, Greifswald, which allows one to estimate the effective dose equivalent in the way recommended by the ICRP. The measuring equipment used, and the methods of calibration and of evaluation of results are described. At present about 400 persons are monthly monitored with a thorax monitor in the nuclear power plant. If an investigation level - corresponding to an effective dose equivalent of 0.3mSv/month - is exceeded, a more exact measurement is made in the whole-body counter at the National Board for Nuclear Safety and Radiation Protection of the GDR. In addition, a selected group of 50 persons is measured twice yearly in the whole-body counter. The measurements show the high effectiveness of the protective measures against radionuclide intake by workers in the nuclear power plant, resulting in a contribution of less than 1% to the collective dose of the personnel. A correlation has been found between external and internal exposure indicating that, in general, there will be a higher intake only under conditions resulting also in higher external exposures. The highest individual values of internal exposure found are below 0.5mSv/month and thus within the range of the lower detection limit of dosimeter films used for monitoring the external exposure. (author)

  8. Occupational exposure to ultrafine particles among airport employees--combining personal monitoring and global positioning system

    DEFF Research Database (Denmark)

    Møller, Karina Lauenborg; Thygesen, Lau Caspar; Schipperijn, Jasper

    2014-01-01

    BACKGROUND: Exposure to ultrafine particles (UFP) has been linked to cardiovascular and lung diseases. Combustion of jet fuel and diesel powered handling equipment emit UFP resulting in potentially high exposure levels among employees working at airports. High levels of UFP have been reported...... at several airports, especially on the apron, but knowledge on individual exposure profiles among different occupational groups working at an airport is lacking. PURPOSE: The aim of this study was to compare personal exposure to UFP among five different occupational groups working at Copenhagen Airport (CPH......). METHOD: 30 employees from five different occupational groups (baggage handlers, catering drivers, cleaning staff and airside and landside security) at CPH were instructed to wear a personal monitor of particle number concentration in real time and a GPS device. The measurements were carried out on 8 days...

  9. Long life of a short film.

    Science.gov (United States)

    Wadia, R V

    2000-01-01

    What follows is an account of my personal experiences as an independent Indian film director who had the fortune to make the country's first openly gay film, the short BOMgAY That said, I would like this essay to be accepted as, rather than a critical appraisal of Indian cinema, a humbly autobiographical account of one individual caught in the hectic throes of political (and cinematic) visibility.

  10. A head-mounted display-based personal integrated-image monitoring system for transurethral resection of the prostate.

    Science.gov (United States)

    Yoshida, Soichiro; Kihara, Kazunori; Takeshita, Hideki; Fujii, Yasuhisa

    2014-12-01

    The head-mounted display (HMD) is a new image monitoring system. We developed the Personal Integrated-image Monitoring System (PIM System) using the HMD (HMZ-T2, Sony Corporation, Tokyo, Japan) in combination with video splitters and multiplexers as a surgical guide system for transurethral resection of the prostate (TURP). The imaging information obtained from the cystoscope, the transurethral ultrasonography (TRUS), the video camera attached to the HMD, and the patient's vital signs monitor were split and integrated by the PIM System and a composite image was displayed by the HMD using a four-split screen technique. Wearing the HMD, the lead surgeon and the assistant could simultaneously and continuously monitor the same information displayed by the HMD in an ergonomically efficient posture. Each participant could independently rearrange the images comprising the composite image depending on the engaging step. Two benign prostatic hyperplasia (BPH) patients underwent TURP performed by surgeons guided with this system. In both cases, the TURP procedure was successfully performed, and their postoperative clinical courses had no remarkable unfavorable events. During the procedure, none of the participants experienced any HMD-wear related adverse effects or reported any discomfort.

  11. Miniaturized inertial impactor for personal airborne particulate monitoring: Prototyping

    Science.gov (United States)

    Pasini, Silvia; Bianchi, Elena; Dubini, Gabriele; Cortelezzi, Luca

    2017-11-01

    Computational fluid dynamic (CFD) simulations allowed us to conceive and design a miniaturized inertial impactor able to collect fine airborne particulate matter (PM10, PM2.5 and PM1). We created, by 3D printing, a prototype of the impactor. We first performed a set of experiments by applying a suction pump to the outlets and sampling the airborne particulate of our laboratory. The analysis of the slide showed a collection of a large number of particles, spanning a wide range of sizes, organized in a narrow band located below the exit of the nozzle. In order to show that our miniaturized inertial impactor can be truly used as a personal air-quality monitor, we performed a second set of experiments where the suction needed to produce the airflow through the impactor is generated by a human being inhaling through the outlets of the prototype. To guarantee a number of particles sufficient to perform a quantitative characterization, we collected particles performing ten consecutive deep inhalations. Finally, the potentiality for realistic applications of our miniaturized inertial impactor used in combination with a miniaturized single-particle detector will be discussed. CARIPLO Fundation - project MINUTE (Grant No. 2011-2118).

  12. Effect of iodine solutions on polyaniline films

    International Nuclear Information System (INIS)

    Ayad, M.M.; Amer, W.A.; Stejskal, J.

    2009-01-01

    Polyaniline (PANI) emeraldine-base films have been exposed to iodine solutions. The interaction between the films and the iodine solution was studied using the quartz-crystal microbalance (QCM) technique and the UV-visible absorption spectroscopy. The iodine-treated film of emeraldine base was subjected to dedoping process using 0.1 M ammonia solution. The resulting film was exposed again to the previously used iodine solution. Iodine was found to play multiple roles: the ring-iodination of PANI film, the oxidation of PANI to pernigraniline base, and iodine doping to PANI salt. A sensor based on PANI-coated electrode of QCM was developed to monitor the presence of iodine in solution.

  13. Personal Change and Intervention Style

    Science.gov (United States)

    Andrews, John D. W.

    1977-01-01

    Presents a theory of personal change and analyzes growth-producing interventions using examples from the film, "Three Approaches to Psychotherapy". Compares the styles of Carl Rogers, Frttz Perls, and Albert Ellis to illustrate the theory. (Editor/RK)

  14. Franz Anton Mesmer, an introverted personality in medicine and film

    Directory of Open Access Journals (Sweden)

    Alberto Enrique D’OTTAVIO

    2016-09-01

    Full Text Available This paper focuses on a controversial figure in Medicine: Franz Anton Mesmer, who lived during the 18th century and the early 19th century. A biographical context, supported in different authors, explains his professional heterodoxy and his eventual legacy to Medicine, providing simultaneously a referential framework for the equally debatable film Mesmer (1994 and allowing a comparison between the historical truthfulness and the non historical changes made in favour of cinematographic language. Historical film with well-matched wardrobe, approaches to us a polemic physician considered just a medical pioneer or, in contrast, a mere fake linked with occultism and swindle.

  15. Flexible PZT Thin Film Tactile Sensor for Biomedical Monitoring

    Directory of Open Access Journals (Sweden)

    Wen-Jong Wu

    2013-04-01

    Full Text Available This paper presents the development of tactile sensors using the sol-gel process to deposit a PZT thin-film from 250 nm to 1 μm on a flexible stainless steel substrate. The PZT thin-film tactile sensor can be used to measure human pulses from several areas, including carotid, brachial, finger, ankle, radial artery, and the apical region. Flexible PZT tactile sensors can overcome the diverse topology of various human regions and sense the corresponding signals from human bodies. The measured arterial pulse waveform can be used to diagnose hypertension and cardiac failure in patients. The proposed sensors have several advantages, such as flexibility, reliability, high strain, low cost, simple fabrication, and low temperature processing. The PZT thin-film deposition process includes a pyrolysis process at 150 °C/500 °C for 10/5 min, followed by an annealing process at 650 °C for 10 min. Finally, the consistent pulse wave velocity (PWV was demonstrated based on human pulse measurements from apical to radial, brachial to radial, and radial to ankle. It is characterized that the sensitivity of our PZT-based tactile sensor was approximately 0.798 mV/g.

  16. Flexible PZT thin film tactile sensor for biomedical monitoring.

    Science.gov (United States)

    Tseng, Hong-Jie; Tian, Wei-Cheng; Wu, Wen-Jong

    2013-04-25

    This paper presents the development of tactile sensors using the sol-gel process to deposit a PZT thin-film from 250 nm to 1 μm on a flexible stainless steel substrate. The PZT thin-film tactile sensor can be used to measure human pulses from several areas, including carotid, brachial, finger, ankle, radial artery, and the apical region. Flexible PZT tactile sensors can overcome the diverse topology of various human regions and sense the corresponding signals from human bodies. The measured arterial pulse waveform can be used to diagnose hypertension and cardiac failure in patients. The proposed sensors have several advantages, such as flexibility, reliability, high strain, low cost, simple fabrication, and low temperature processing. The PZT thin-film deposition process includes a pyrolysis process at 150 °C/500 °C for 10/5 min, followed by an annealing process at 650 °C for 10 min. Finally, the consistent pulse wave velocity (PWV) was demonstrated based on human pulse measurements from apical to radial, brachial to radial, and radial to ankle. It is characterized that the sensitivity of our PZT-based tactile sensor was approximately 0.798 mV/g.

  17. Uniting Hispanic Film Studies with Civic Engagement: A Chance for Personal Transformation

    Science.gov (United States)

    Larson, Kajsa C.

    2015-01-01

    This current study presents a unique approach to the examination of Hispanic film through the incorporation of a civic engagement project, the Mayerson Student Philanthropy Project (MSPP), into the curriculum. Students examined and assessed important global issues, and how they are portrayed in films from several Spanish-speaking countries, while…

  18. Relaxation in Thin Polymer Films Mapped across the Film Thickness by Astigmatic Single-Molecule Imaging

    KAUST Repository

    Oba, Tatsuya

    2012-06-19

    We have studied relaxation processes in thin supported films of poly(methyl acrylate) at the temperature corresponding to 13 K above the glass transition by monitoring the reorientation of single perylenediimide molecules doped into the films. The axial position of the dye molecules across the thickness of the film was determined with a resolution of 12 nm by analyzing astigmatic fluorescence images. The average relaxation times of the rotating molecules do not depend on the overall thickness of the film between 20 and 110 nm. The relaxation times also do not show any dependence on the axial position within the films for the film thickness between 70 and 110 nm. In addition to the rotating molecules we observed a fraction of spatially diffusing molecules and completely immobile molecules. These molecules indicate the presence of thin (<5 nm) high-mobility surface layer and low-mobility layer at the interface with the substrate. (Figure presented) © 2012 American Chemical Society.

  19. Monitoring apparatus for monitoring a user's heart rate and/or heart rate variation

    NARCIS (Netherlands)

    2012-01-01

    A monitoring apparatus (4) monitors a user's heart rate and/or heart rate variation. The apparatus includes a capacitor (22) which is positionable on or near a body part of a person, for example a person's limb, for example an arm (3), such that an electrical capacitance of the capacitor (22) is

  20. A Framework for Evaluating the Software Product Quality of Pregnancy Monitoring Mobile Personal Health Records.

    Science.gov (United States)

    Idri, Ali; Bachiri, Mariam; Fernández-Alemán, José Luis

    2016-03-01

    Stakeholders' needs and expectations are identified by means of software quality requirements, which have an impact on software product quality. In this paper, we present a set of requirements for mobile personal health records (mPHRs) for pregnancy monitoring, which have been extracted from literature and existing mobile apps on the market. We also use the ISO/IEC 25030 standard to suggest the requirements that should be considered during the quality evaluation of these mPHRs. We then go on to design a checklist in which we contrast the mPHRs for pregnancy monitoring requirements with software product quality characteristics and sub-characteristics in order to calculate the impact of these requirements on software product quality, using the ISO/IEC 25010 software product quality standard. The results obtained show that the requirements related to the user's actions and the app's features have the most impact on the external sub-characteristics of the software product quality model. The only sub-characteristic affected by all the requirements is Appropriateness of Functional suitability. The characteristic Operability is affected by 95% of the requirements while the lowest degrees of impact were identified for Compatibility (15%) and Transferability (6%). Lastly, the degrees of the impact of the mPHRs for pregnancy monitoring requirements are discussed in order to provide appropriate recommendations for the developers and stakeholders of mPHRs for pregnancy monitoring.

  1. Breath acetone monitoring by portable Si:WO3 gas sensors

    International Nuclear Information System (INIS)

    Righettoni, Marco; Tricoli, Antonio; Gass, Samuel; Schmid, Alex; Amann, Anton; Pratsinis, Sotiris E.

    2012-01-01

    Highlights: ► Portable sensors were developed and tested for monitoring acetone in the human breath. ► Acetone concentrations down to 20 ppb were measured with short response times ( 3 nanostructured films was developed. The chamber volume was miniaturized while reaction-limited and transport-limited gas flow rates were identified and sensing temperatures were optimized resulting in a low detection limit of acetone (∼20 ppb) with short response (10–15 s) and recovery times (35–70 s). Furthermore, the sensor signal (response) was robust against variations of the exhaled breath flow rate facilitating application of these sensors at realistic relative humidities (80–90%) as in the human breath. The acetone content in the breath of test persons was monitored continuously and compared to that of state-of-the-art proton transfer reaction mass spectrometry (PTR-MS). Such portable devices can accurately track breath acetone concentration to become an alternative to more elaborate breath analysis techniques.

  2. Monitoring and life-support devices

    International Nuclear Information System (INIS)

    Noback, C.R.; Murphy, C.H.

    1987-01-01

    The radiographic and physical principles involved in interpreting films, and some of the altered anatomy and pathology that may be seen on such films, are discussed. This chapter considers the radiographic appearances of monitoring and life-support devices. Appropriate positioning and function are shown, as are some of the complications associated with their placement and/or function

  3. A Wireless Posture Monitoring System for Personalized Home-Based Rehabilitation

    Directory of Open Access Journals (Sweden)

    Pedro Macedo

    2015-06-01

    Full Text Available We live in an aging society, an issue that will be exacerbated in the coming decades, due to low birth rates and increasing life expectancy. With the decline in physical and cognitive functions with age, it is of the utmost importance to maintain regular physical activity, in order to preserve an individual’s mobility, motor capabilities and coordination. Within this context, this paper describes the development of a wireless sensor network and its application in a human motion capture system based on wearable inertial and magnetic sensors. The goal is to enable, through continuous real- time monitoring, the creation of a personalized home-based rehabilitation system for the elderly population and/or injured people. Within this system, the user can benefit from an assisted mode, in which their movements can be compared to a reference motion model of the same movements, resulting in visual feedback alerts given by the application. This motion model can be created previously, in a ‘learning phase’, under supervision of a caregiver.

  4. A module for psycho-social assessment of personal health monitoring.

    Science.gov (United States)

    Muehlan, Holger; Rhode, Dieter; Schmidt, Silke

    2013-01-01

    This contribution to an interdisciplinary methodology on Personal Health Monitoring (PHM) aims at developing a psycho-social module for health technology assessment on PHM applications. It covers important aspects that should be taken into account for conducting a health technology assessment from a psycho-social perspective. As it could be used in addition to other tools within the PHM-Ethics approach to health technology assessment it is considered as a module of the interdisciplinary methodology. As a prerequisite, we provide a conceptual framework on psycho-social issues of PHM applications. From that framework we delineate an integrated module for psycho-social health technology assessment for PHM applications, consisting of a map highlighting selective psycho-social issues that may appear when applying a PHM system. This psycho-social tool is at least twofold in its intention as a sole HTA tool on the one hand and as an integral part of the interdisciplinary PHM methodology on the other hand. It provides a quick overview on potential benefits and risks from the user's point of view.

  5. Cholesterol monohydrate nucleation in ultrathin films on water

    DEFF Research Database (Denmark)

    Rapaport, H.; Kuzmenko, I.; Lafont, S.

    2001-01-01

    The growth of a cholesterol crystalline phase, three molecular layers thick at the air-water interface, was monitored by grazing incidence x-ray diffraction and x-ray reflectivity. Upon compression, a cholesterol film transforms from a monolayer of trigonal symmetry and low crystallinity to a tri......The growth of a cholesterol crystalline phase, three molecular layers thick at the air-water interface, was monitored by grazing incidence x-ray diffraction and x-ray reflectivity. Upon compression, a cholesterol film transforms from a monolayer of trigonal symmetry and low crystallinity...... in pathological lipid deposits....

  6. In situ measurement of conductivity during nanocomposite film deposition

    International Nuclear Information System (INIS)

    Blattmann, Christoph O.; Pratsinis, Sotiris E.

    2016-01-01

    Highlights: • Flame-made nanosilver dynamics are elucidated in the gas-phase & on substrates. • The resistance of freshly depositing nanosilver layers is monitored. • Low T g polymers facilitate rapid synthesis of conductive films. • Conductive nanosilver films form on top of or within the polymer depending on MW. - Abstract: Flexible and electrically conductive nanocomposite films are essential for small, portable and even implantable electronic devices. Typically, such film synthesis and conductivity measurement are carried out sequentially. As a result, optimization of filler loading and size/morphology characteristics with respect to film conductivity is rather tedious and costly. Here, freshly-made Ag nanoparticles (nanosilver) are made by scalable flame aerosol technology and directly deposited onto polymeric (polystyrene and poly(methyl methacrylate)) films during which the resistance of the resulting nanocomposite is measured in situ. The formation and gas-phase growth of such flame-made nanosilver, just before incorporation onto the polymer film, is measured by thermophoretic sampling and microscopy. Monitoring the nanocomposite resistance in situ reveals the onset of conductive network formation by the deposited nanosilver growth and sinternecking. The in situ measurement is much faster and more accurate than conventional ex situ four-point resistance measurements since an electrically percolating network is detected upon its formation by the in situ technique. Nevertheless, general resistance trends with respect to filler loading and host polymer composition are consistent for both in situ and ex situ measurements. The time lag for the onset of a conductive network (i.e., percolation) depends linearly on the glass transition temperature (T g ) of the host polymer. This is attributed to the increased nanoparticle-polymer interaction with decreasing T g . Proper selection of the host polymer in combination with in situ resistance monitoring

  7. An unshielded whole body radioactivity counter for monitoring persons after a radiation accident

    International Nuclear Information System (INIS)

    Katoch, D.S.; Somasundaram, S.

    1979-01-01

    An unshielded chair in which the subject sits, holding a 7.6 cm x 7.6 cm NaI (Tl) detector in his lap, was evaluated for monitoring of persons suspected of internal radioactive contamination following a radiation accident. The reduction in different energy bands of the background gamma-ray spectrum due to self-shielding of the subject was studied for two postures, designated ''upright'' and ''folding'' and the data were analysed in a CDC 3600 computer to obtain the best-fit regression equation relating the reduction factor with body weight and height. The response of the counter was evaluated using an in vitro method and the ranges of under/over-estimation of body burden resulting from assumption of partial/uniform distribution of activity were determined. Counting sensitivities were derived for 13 radioisotopes having gamma-ray energies in the range 145 keV-1.46 MeV. The results are presented and discussed. The study shows that this simple system may be used not only in radiation emergencies but also for operational monitoring of radiation workers for a number of radioisotopes of low and medium radiotoxicity. (auth.)

  8. Can verbal instruction enhance the recall of an everyday task and promote error-monitoring in people with dementia of the Alzheimer-type?

    Science.gov (United States)

    Balouch, Sara; Rusted, Jennifer M

    2017-03-01

    People with dementia of the Alzheimer-type (DAT) have difficulties with performing everyday tasks, and error awareness is poor. Here we investigate whether recall of actions and error monitoring in everyday task performance improved when they instructed another person on how to make tea. In this situation, both visual and motor cues are present, and attention is sustained by the requirement to keep instructing. The data were drawn from a longitudinal study recording performance in four participants with DAT, filmed regularly for five years in their own homes, completing three tea-making conditions: performed-recall (they made tea themselves); instructed-recall (they instructed the experimenter on how to make tea); and verbal-recall (they described how to make tea). Accomplishment scores (percentage of task they correctly recalled), errors and error-monitoring were coded. Task accomplishment was comparable in the performed-recall and instructed-recall conditions, but both were significantly better than task accomplishment in the verbal-recall condition. Third person instruction did not improve error-monitoring. This study has implications for everyday task rehabilitation for people with DAT.

  9. New web interface for Personal dosimetry VF, a.s

    International Nuclear Information System (INIS)

    Studeny, J.

    2014-01-01

    The lecture will introduce new functions and graphic design WebSOD - web interface Personal dosimetry Service VF. a.s. which will be updated in November 2014. The new interface will have a new graphic design, intuitive control system and will be providing a range of new functions: - Personal doses - display of personal doses from personal, extremity and neutron dosimeters including graphs, annual and electronic listings of doses; - Collective doses - display of group doses for selected periods of time; Reference levels - setting and display of three reference levels; - Evidence - enables administration of monitored individuals - beginning, ending of monitoring, or editing the data of monitored persons and centers. (author)

  10. On-line use of personal computers to monitor and evaluate important parameters in the research reactor DHRUVA

    International Nuclear Information System (INIS)

    Sharma, S.K.; Sengupta, S.N.; Darbhe, M.D.; Agarwal, S.K.

    1998-01-01

    The on-line use of Personal Computers in research reactors, with custom made applications for aiding the operators in analysing plant conditions under normal and abnormal situations, has become extremely popular. A system has been developed to monitor and evaluate important parameters for the research reactor DHRUVA, a 100 MW research reactor located at the Bhabha Atomic Research Centre, Trombay. The system was essentially designed for on-line computation of the following parameters: reactor thermal power, reactivity load due to Xenon, core reactivity balance and performance monitoring of shut-down devices. Apart from the on-line applications, the system has also been developed to cater some off-line applications with Local Area Network in the Dhruva complex. The microprocessor based system is designed to function as an independent unit, parallel dumping the acquired data to a PC for application programmes. The user interface on the personal computer is menu driven application software written in 'C' language. The main input parameters required for carrying out the options given in the above menu are: Reactor power, Moderator level, Coolant inlet temperature to the core, Secondary coolant flow rate, temperature rise of secondary coolant across the heat exchangers, heavy water level in the Dump tank and Drop time of individual shut off rods. (author)

  11. Flexible Conductive Composite Integrated with Personal Earphone for Wireless, Real-Time Monitoring of Electrophysiological Signs.

    Science.gov (United States)

    Lee, Joong Hoon; Hwang, Ji-Young; Zhu, Jia; Hwang, Ha Ryeon; Lee, Seung Min; Cheng, Huanyu; Lee, Sang-Hoon; Hwang, Suk-Won

    2018-06-14

    We introduce optimized elastomeric conductive electrodes using a mixture of silver nanowires (AgNWs) with carbon nanotubes/polydimethylsiloxane (CNTs/PDMS), to build a portable earphone type of wearable system that is designed to enable recording electrophysiological activities as well as listening to music at the same time. A custom-built, plastic frame integrated with soft, deformable fabric-based memory foam of earmuffs facilitates essential electronic components, such as conductive elastomers, metal strips, signal transducers and a speaker. Such platform incorporates with accessory cables to attain wireless, real-time monitoring of electrical potentials whose information can be displayed on a cell phone during outdoor activities and music appreciation. Careful evaluations on experimental results reveal that the performance of fabricated dry electrodes are comparable to that of commercial wet electrodes, and position-dependent signal behaviors provide a route toward accomplishing maximized signal quality. This research offers a facile approach for a wearable healthcare monitor via integration of soft electronic constituents with personal belongings.

  12. Ground-based photo monitoring

    Science.gov (United States)

    Frederick C. Hall

    2000-01-01

    Ground-based photo monitoring is repeat photography using ground-based cameras to document change in vegetation or soil. Assume those installing the photo location will not be the ones re-photographing it. This requires a protocol that includes: (1) a map to locate the monitoring area, (2) another map diagramming the photographic layout, (3) type and make of film such...

  13. SSDL Preparation for Implementation of the Use of OSL Dosimeters in Malaysia

    International Nuclear Information System (INIS)

    Sangau, J.K.; Taiman Kadni; Ahmad Bazlie Abdul Kadir

    2013-01-01

    Since the early 1980's, film badge has been widely used as a device of personal dose monitoring in Malaysia. Secondary Standard Dosimetry Laboratory (SSDL), as a service center for film badge has obtained the supply of personal monitoring film from Agfa Gevaert, Belgium every year. As the uses of film badge have some weaknesses, it has prompted SSDL to find an alternative dosimeter to replace the film badge. Based on the studies that have been conducted, SSDL has selected OSL dosimeter (Optically Stimulated Luminescent Dosimeter) to replace the film badge and is expected to be fully operational by middle of 2015. This paper aims to explain the selection of OSL dosimeter and planning carried out to ensure the success of their application in Malaysia. (author)

  14. Voltage-Controlled Topotactic Phase Transition in Thin-Film SrCoOx Monitored by In Situ X-ray Diffraction.

    Science.gov (United States)

    Lu, Qiyang; Yildiz, Bilge

    2016-02-10

    Topotactic phase transition of functional oxides induced by changes in oxygen nonstoichiometry can largely alter multiple physical and chemical properties, including electrical conductivity, magnetic state, oxygen diffusivity, and electrocatalytic reactivity. For tuning these properties reversibly, feasible means to control oxygen nonstoichiometry-dependent phase transitions in functional oxides are needed. This paper describes the use of electrochemical potential to induce phase transition in strontium cobaltites, SrCoOx (SCO) between the brownmillerite (BM) phase, SrCoO₂.₅, and the perovskite (P) phase, SrCoO₃₋δ. To monitor the structural evolution of SCO, in situ X-ray diffraction (XRD) was performed on an electrochemical cell having (001) oriented thin-film SrCoOx as the working electrode on a single crystal (001) yttria-stabilized zirconia electrolyte in air. In order to change the effective pO₂ in SCO and trigger the phase transition from BM to P, external electrical biases of up to 200 mV were applied across the SCO film. The phase transition from BM to P phase could be triggered at a bias as low as 30 mV, corresponding to an effective pO₂ of 1 atm at 500 °C. The phase transition was fully reversible and the epitaxial film quality was maintained after reversible phase transitions. These results demonstrate the use of electrical bias to obtain fast and easily accessible switching between different phases as well as distinct physical and chemical properties of functional oxides as exemplified here for SCO.

  15. Ethically sound technology? Guidelines for interactive ethical assessment of personal health monitoring.

    Science.gov (United States)

    Palm, Elin; Nordgren, Anders; Verweij, Marcel; Collste, Göran

    2013-01-01

    Novel care-technologies possess a transformational potential. Future care and support may be provided via monitoring technologies such as smart devices, sensors, actors (robots) and Information and Communication Technologies. Such technologies enable care provision outside traditional care institutions, for instance in the homes of patients. Health monitoring may become "personalized" i.e. tailored to the needs of individual care recipients' but may also alter relations between care providers and care recipents, shape and form the care environment and influence values central to health-care. Starting out from a social constructivist theory of technology, an interactive ethical assessment-model is offered. The suggested model supplements a traditional analysis based on normative ethical theory (top-down approach) with interviews including relevant stakeholders (a bottom-up approach). This method has been piloted by small-scale interviews encircling stakeholder perspectives on three emerging technologies: (1) Careousel, a smart medicine-management device, (2) Robot Giraff, an interactive and mobile communication-device and (3) I-Care, a care-software that combines alarm and register system. By incorporating stakeholder perspectives into the analysis, the interactive ethical assessment model provides a richer understanding of the impact of PHM-technologies on ethical values than a traditional top-down model. If the assessment is conducted before the technology has reached the market - preferably in close interaction with developers and users - ethically sound technologies may be obtained.

  16. A new radiochromic dosimeter film

    Science.gov (United States)

    Sidney, L. N.; Lynch, D. C.; Willet, P. S.

    By employing acid-sensitive leuco dyes in a chlorine-containing polymer matrix, a new radiochromic dosimeter film has been developed for gamma, electron beam, and ultraviolet radiation. These dosimeter films undergo a color change from colorless to royal blue, red fuchsia, or black, depending on dye selection, and have been characterized using a visible spectrophotometer over an absorbed dose range of 1 to 100 kGy. The primary features of the film are improved color stability before and after irradiation, whether stored in the dark or under artificial lights, and improved moisture resistance. The effects of absorbed dose, dose rate, and storage conditions on dosimeter performance are discussed. The dosimeter material may be produced as a free film or coated onto a transparent substrate and optionally backed with adhesive. Potential applications for these materials include gamma sterilization indicator films for food and medical products, electron beam dosimeters, and in-line radiation monitors for electron beam and ultraviolet processing.

  17. Swelling of a Zirconium Oxide Film

    International Nuclear Information System (INIS)

    Henderson, Mark; Hawley, Adrian; White, John; Rennie, Adrian

    2005-01-01

    Full text: The structural changes that cause the change in the interlayer spacing of a surfactanttemplated zirconium oxide film have been studied using neutron diffractometry. We report that the film after drying on a glass substrate swells slightly through the addition of benzene by up to 4 Aangstroem on a lattice parameter of about 36 Aangstroem. The (001) and (002) diffraction peaks positions, widths and areas of a swollen film were then monitored by neutron diffraction as a function of benzene desorption. Disorder of the lamellar mesophase is considered as a cause of the observed effects on the diffraction signals. (authors)

  18. Extruded blend films of poly(vinyl alcohol) and polyolefins: common and hard-elastic nanostructure evolution in the polyolefin during straining as monitored by SAXS

    International Nuclear Information System (INIS)

    Stribeck, Norbert; Zeinolebadi, Ahmad; Fakirov, Stoyko; Bhattacharyya, Debes; Botta, Stephan

    2013-01-01

    Straining of PVA/PE and PVA/PP blends (70:30) is monitored by small-angle x-ray scattering (SAXS). Sheet-extruded films with different predraw ratio are investigated. The discrete SAXS of predrawn samples originates from polyolefin nanofibrils inside of polyolefin microfibrils immersed in a PVA matrix. PE nanofibrils deform less than the macroscopic strain without volume change. PP nanofibrils experience macroscopic strain. They lengthen but their diameter does not decrease. This is explained by strain-induced crystallization of PP from an amorphous depletion shell around the core of the nanofibril. The undrawn PVA/PE film exhibits isotropic semicrystalline nanostructure. Undrawn PVA/PP holds PP droplets containing oriented stacks of semicrystalline PP like neat precursors of hard-elastic thermoplasts. Respective predrawn films are softer than the undrawn material, indicating conversion into the hard-elastic state. Embedding of the polyolefin significantly retards neck formation. The polyolefin microfibrils can easily be extracted from the water-soluble matrix. (paper)

  19. FILM/TALK: Photography A Visual Language: The Landscape Document Part 1

    OpenAIRE

    Murray, Matthew; United Nations of Photography; Film courtesy of Reece Pickering and Tchad Findlay

    2016-01-01

    This short film is part of a conversation featuring photographers Marc Wilson, Brian David Stevens and Matthew Murray hosted by Ian McGuffie. In this film they passionately discuss the highly personal inspirations for their work, their process of working, the importance of history in personal experience and the role of landscape photography as a social document. \\ud \\ud This talk was part of a day of talks titled Photography A Visual language: A Day of Conversation held by us in collaboration...

  20. Development of an automatic smear sampler and a polymer film for surface radioactive contamination assay

    International Nuclear Information System (INIS)

    Seo, B.-K.; Lee, K.-W.; Woo, Z.-H.; Jeong, K.-S.; Oh, W.-Z.; Han, M.-J.

    2004-01-01

    Measurement of the surface contamination by an indirect method is subject to the various kinds of error according to the sampling person and needs much time and effort in the sampling and assay. In this research, an automatic smear sampler is developed. It improved efficiency for assay work of surface contamination level achieved periodically in a radiation controlled area. Using an automatic smear sampler developed, it is confirmed that radioactive contaminated materials are uniformly transferred to smear paper more than any sampling method by an operator. Also, Solid scintillation proximity membranes were prepared for measuring the amount of radioactive contamination in laboratories contaminated by the low energy beta-ray emitter, such as 3 H and 14 C. Polysulfone scintillation proximity membranes were prepared by impregnating Cerium Activated Yttrium Silicate (CAYS), an inorganic fluor, in a membrane structure. The inorganic fluor-impregnated membranes were applied to detect the radioactive surface contamination. The preparation of membranes was divided into two processes. A supporting polymer film was made of casting solutions consisting of polysulfone and solvent, their cast film being solidified by vacuum evaporation. CAYS-dispersed polymer solutions were cast over the first, solidified polymer films and coagulated either by evaporating solvent in the solution with non-solvent in a coagulation bath. The prepared membranes had two distinguished, but tightly attached, double layers : one is the supporting layer of dense polymer film and the other results revealed that the prepared membranes were efficient to monitor radioactive contamination with reliable counting ability. For enhancement of pick-up and measurement efficiency, the membrane was prepared with the condition of different membrane solidification. The scintillation produced by interaction with radiation and CAYS was measured with photomultiplier tube. The test results showed that the prepared

  1. Working level measurement of radon daughters and thoron daughters by personal dosimetry and continuous monitoring

    International Nuclear Information System (INIS)

    Phillips, C.R.; Leung, H.

    1981-01-01

    The performance of personal alpha dosimeters in mixed radon daughter and thoron daughter atmospheres in Ontario uranium mines is described together with monitoring developments which enable the radon daughter working level to be determined separately. The theoretical bases for continuous and integrated working level measurements based on individual and gross counts are presented in terms of the weighting factor for combining the thoron daughter working level with the radon daughter working level, and in terms of the in-growth time of the air. Implications for the determination of working level in the presence of thoron daughters are discussed

  2. Miniaturized inertial impactor for personal airborne particulate monitoring: Numerical model

    Science.gov (United States)

    Cortelezzi, Luca; Pasini, Silvia; Bianchi, Elena; Dubini, Gabriele

    2017-11-01

    The rising level of fine particle matter's (PM10, PM2.5 and PM1) pollution in the world has increased the interest in developing portable personal air-qualitity monitoring systems. To answer this need, we conceived a miniaturized inertial impactor. The development of such an impactor becomes more challenging as the diameter of the particles to be collected becomes smaller, since the velocities required to induce the impact of finer particulate matter become higher. To overcome these challenges, we modeled numerically the fluid dynamics and particles transport within the impactor. Our simulations show that the fluid flow within the impactor becomes unstable as the Reynolds number is increased to capture finer particles. Furthermore, the onset of these instabilities depends not only on the Reynolds number but also on the geometry of the impactor. The unsteady flow within the impactor influences the trajectories of the particles to be collected, especially the smaller particles. The particles trajectories shows that the impaction location varies substantially as the Reynolds number increases and, consequently, the efficiency of the impactor deteriorates. Finally, we optimize the design of our impactor to maximize its collection efficiency. CARIPLO Fundation - project MINUTE (Grant No. 2011-2118).

  3. Study progression in application of process analytical technologies on film coating

    Directory of Open Access Journals (Sweden)

    Tingting Peng

    2015-06-01

    Full Text Available Film coating is an important unit operation to produce solid dosage forms, thereby, the monitoring of this process is helpful to find problems in time and improve the quality of coated products. Traditional methods adopted to monitor this process include measurement of coating weight gain, performance of disintegration and dissolution test, etc. However, not only do these methods cause destruction to the samples, but also consume time and energy. There have recently emerged the applications of process analytical technologies (PAT on film coating, especially some novel spectroscopic and imaging technologies, which have the potential to real-time track the progress in film coating and optimize production efficiency. This article gives an overview on the application of such technologies for film coating, with the goal to provide a reference for the further researches.

  4. Density determination of langmuir-blodgett monolayer films using x-ray reflectivity technique

    International Nuclear Information System (INIS)

    Damar Yoga Kusuma

    2015-01-01

    Monolayer deposition by Langmuir-Blodgett technique produces monolayer films that are uniform with controllable thickness down to nanometer scale. To evaluate the quality of the monolayer deposition, X-ray reflectivity technique are employed to monitor the monolayers density. Langmuir-Blodgett monolayer with good coverage and uniformity results in film density close to its macroscopic film counterpart whereas films with presence of air gaps shows lower density compared to its macroscopic film counterpart. (author)

  5. Reliability of Sleep Measures from Four Personal Health Monitoring Devices Compared to Research-Based Actigraphy and Polysomnography

    Directory of Open Access Journals (Sweden)

    Janna Mantua

    2016-05-01

    Full Text Available Polysomnography (PSG is the “gold standard” for monitoring sleep. Alternatives to PSG are of interest for clinical, research, and personal use. Wrist-worn actigraph devices have been utilized in research settings for measures of sleep for over two decades. Whether sleep measures from commercially available devices are similarly valid is unknown. We sought to determine the validity of five wearable devices: Basis Health Tracker, Misfit Shine, Fitbit Flex, Withings Pulse O2, and a research-based actigraph, Actiwatch Spectrum. We used Wilcoxon Signed Rank tests to assess differences between devices relative to PSG and correlational analysis to assess the strength of the relationship. Data loss was greatest for Fitbit and Misfit. For all devices, we found no difference and strong correlation of total sleep time with PSG. Sleep efficiency differed from PSG for Withings, Misfit, Fitbit, and Basis, while Actiwatch mean values did not differ from that of PSG. Only mean values of sleep efficiency (time asleep/time in bed from Actiwatch correlated with PSG, yet this correlation was weak. Light sleep time differed from PSG (nREM1 + nREM2 for all devices. Measures of Deep sleep time did not differ from PSG (SWS + REM for Basis. These results reveal the current strengths and limitations in sleep estimates produced by personal health monitoring devices and point to a need for future development.

  6. Personality correlates of the Five-Factor Model for a sample of business owners/managers: associations with scores on Self-Monitoring, Type A Behavior, Locus of Control, and Subjective Well-being.

    Science.gov (United States)

    Morrison, K A

    1997-02-01

    Bivariate relationships were examined between scores on the Five-Factor Model of personality and four personality dimensions including Self-monitoring, Locus of Control, Type A Behavior, and Subjective Well-being. Data were collected from 307 franchise business owner/managers from four different industries. Scores for Self-monitoring were positively related to those on Extraversion; Self-monitoring was the only personality measure significantly correlated with scores on Openness to Experience. Scores for Type A Behavior, measured by the Jenkins Activity Survey, were negatively correlated with Agreeableness and positively correlated with those for Extraversion. Somewhat surprisingly, the score for Type A Behavior had a relatively low correlation with the score for Conscientiousness. Scores for Subjective Well-being and Locus of Control were most strongly correlated with the positive pole of Neuroticism (Emotional Stability), Conscientiousness, and Extraversion. Possible explanations for the observed relationships are discussed.

  7. Biocompatible Poly(catecholamine)-Film Electrode for Potentiometric Cell Sensing.

    Science.gov (United States)

    Kajisa, Taira; Yanagimoto, Yoshiyuki; Saito, Akiko; Sakata, Toshiya

    2018-02-23

    Surface-coated poly(catecholamine) (pCA) films have attracted attention as biomaterial interfaces owing to their biocompatible and physicochemical characteristics. In this paper, we report that pCA-film-coated electrodes are useful for potentiometric biosensing devices. Four different types of pCA film, l-dopa, dopamine, norepinephrine, and epinephrine, with thicknesses in the range of 7-27 nm were electropolymerized by oxidation on Au electrodes by using cyclic voltammetry. By using the pCA-film electrodes, the pH responsivities were found to be 39.3-47.7 mV/pH within the pH range of 1.68 to 10.01 on the basis of the equilibrium reaction with hydrogen ions and the functional groups of the pCAs. The pCA films suppressed nonspecific signals generated by other ions (Na + , K + , Ca 2+ ) and proteins such as albumin. Thus, the pCA-film electrodes can be used in pH-sensitive and pH-selective biosensors. HeLa cells were cultivated on the surface of the pCA-film electrodes to monitor cellular activities. The surface potential of the pCA-film electrodes changed markedly because of cellular activity; therefore, the change in the hydrogen ion concentration around the cell/pCA-film interface could be monitored in real time. This was caused by carbon dioxide or lactic acid that is generated by cellular respiration and dissolves in the culture medium, resulting in the change of hydrogen concentration. pCA-film electrodes are suitable for use in biocompatible and pH-responsive biosensors, enabling the more selective detection of biological phenomena.

  8. [THE ORGANIZATIONAL TECHNOLOGIES OF INCREASING OF EFFECTIVENESS OF DISPENSARY MONITORING OF HIV-INFECTED PERSONS].

    Science.gov (United States)

    Moskvitcheva, M G; Yu, Kitmanova L

    2015-01-01

    The organizational technologies of increasing effectiveness ofdispensarization monitoring of HIV-infected persons are to targeted to development in patients commitment to get medical care. The cohort monitoring of registered patients receiving anti-retrovirus therapy permitted to evaluate effectiveness of organizational model of multi-professional team developing commitment ofpatients to anti-retrovirus therapy in conditions of center ofprevention and struggle with AIDS and infectious diseases. The criteria ofeffectiveness offunctioning ofmulti-professional team are developed and implemented The list of criteria include percentage of patients in cohort with optimal commitment (not lower than 95% of applied dosage of anti-retrovirus pharmaceuticals at 12th, 24th, 36th, 48th and 60th month), percentage ofpatients with achieved effect of anti-retrovirus therapy, percentage of patients proceeding anti-retrovirus therapy. The multi-professional team implemented motivational techniques of behavior alteration and patient-oriented care. The main strategy of development of of commitment to anti-retrovirus therapy under HIV-infection is determined as management of resources and risks capable decreasing commitment to dispensarization monitoring. The analysis of problems permitted to structure them in risks of commitment failure: medical (13.7%), medical biological under using psychoactive substances (43.1%), psychological (27.7%), social (15.5%). This listing determined the profile of specialists of multi-professional team. The ranking of risks lead out to the first ranking place medical risks, including diagnosed tuberculosis, combination of secondary and concomitant diseases inpatient, number of intaking pills more than 7 per day. The second ranking place took medical biological risks in users of psychoactive substances. Up to 60th month the anti-retrovirus therapy was proceeded by 61.5% of users of psychoactive substances with optimal commitment in 60%. The implementation

  9. Spark counting technique with an aluminium oxide film

    International Nuclear Information System (INIS)

    Kawai, H.; Koga, T.; Morishima, H.; Niwa, T.; Nishiwaki, Y.

    1980-01-01

    Automatic spark counting of etch-pits on a polycarbonate film produced by nuclear fission fragments is now used for neutron monitoring in several countries. A method was developed using an aluminium oxide film instead of a polycarbonate as the neutron detector. Aluminium oxide films were prepared as follows: A cleaned aluminium plate as an anode and a nickel plate as a cathode were immersed in dilute sulfuric acid solution and electric current flowed between the electrodes at 12degC for 10-30 minutes. Electric current density was about 10 mA/cm 2 . The aluminium plate was then kept in boiling water for 10-30 minutes for sealing. The thickness of the aluminium oxide layer formed was about 1μm. The aluminium plate attached to a plate of suitable fissionable material, such as uranium or thorium, was irradiated with neutrons and set in a usual spark counter for fission track counting. One electrode was the aluminium plate and the other was an aluminized polyester sheet. Sparked pulses were counted with a usual scaler. The advantage of using spark counting with an aluminium oxide film for neutron monitoring is rapid measurement of neutron exposure, since chemical etching which is indispensable for spark counting with a polycarbonate detector film, is not needed. (H.K.)

  10. Variable angle spectroscopic ellipsometric characterization of HfO2 thin film

    Science.gov (United States)

    Kumar, M.; Kumari, N.; Karar, V.; Sharma, A. L.

    2018-02-01

    Hafnium Oxide film was deposited on BK7 glass substrate using reactive oxygenated E-Beam deposition technique. The film was deposited using in-situ quartz crystal thickness monitoring to control the film thickness and rate of evaporation. The thin film was grown with a rate of deposition of 0.3 nm/s. The coated substrate was optically characterized using spectrophotometer to determine its transmission spectra. The optical constants as well as film thickness of the hafnia film were extracted by variable angle spectroscopic ellipsometry with Cauchy fitting at incidence angles of 65˚, 70˚ and 75˚.

  11. Geophysical data collection using an interactive personal computer system. Part 1. ; Experimental monitoring of Suwanosejima volcano

    Energy Technology Data Exchange (ETDEWEB)

    Iguchi, M. (Kyoto Univerdity, Kyoto (Japan). Disaster Prevention Reserach Institute)

    1991-10-15

    In the article, a computer-communication system was developed in order to collect geophysical data from remote volcanos via a public telephpne network. This system is composed of a host presonal computer at an observatory and several personal computers as terminals at remote stations. Each terminal acquires geophysical data, such as seismic, intrasonic, and ground deformation date. These gara are stored in the terminals temporarily, and transmitted to the host computer upon command from host computer. Experimental monitoring was conducted between Sakurajima Volcanological Observatory and several statins in the Satsunan Islands and southern Kyushu. The seismic and eruptive activities of Suwanosejima volcano were monitored by this system. Consequently, earthquakes and air-shocks accompanied by the explosive activity were observed. B-type earthquakes occurred prio to the relatively prolonged eruptive activity. Intermittent occurrences of volcanic tremors were also clearly recognized from the change in mean amplitubes of seismic waves. 7 refs., 10 figs., 2 tabs.

  12. Self-Monitoring in Middle Childhood: Personality and Social Correlates.

    Science.gov (United States)

    Musser, Lynn M.; Browne, Beverly A.

    1991-01-01

    Measures of self-monitoring and other measures were completed by 93 elementary school children on 3 occasions during a 15-month period. Self-monitoring was related to peer acceptance and self-esteem, but the relation may have been influenced by gender. Boys' self-monitoring correlated with popularity measures, whereas girls' did not. (BC)

  13. Swelling of a mesostructured zirconium oxide film

    Energy Technology Data Exchange (ETDEWEB)

    Henderson, M.J. [Research School of Chemistry, Australian National University, Canberra, ACT 0200 (Australia); Rennie, A.R. [Uppsala University, Studsvik Neutron Research Laboratory, S-611 82 Nykoeping (Sweden); Hawley, A.M. [Research School of Chemistry, Australian National University, Canberra, ACT 0200 (Australia); White, J.W. [Research School of Chemistry, Australian National University, Canberra, ACT 0200 (Australia)]. E-mail: jww@rsc.anu.edu.au

    2006-11-15

    The structural changes that cause the change in interlayer spacing of a surfactant-templated zirconium oxide film have been studied using neutron diffractometry. We report that the film after drying on a glass substrate swells slightly through the addition of benzene by up to 4 A on a lattice parameter of about 36 A. The (0 0 1) and (0 0 2) diffraction peak widths, positions and areas of a swollen film were monitored as a function of benzene desorption. Disorder of the lamellar mesophase is considered as a cause of the observed effects on the diffraction signals.

  14. Personality in cyberspace: personal Web sites as media for personality expressions and impressions.

    Science.gov (United States)

    Marcus, Bernd; Machilek, Franz; Schütz, Astrid

    2006-06-01

    This research examined the personality of owners of personal Web sites based on self-reports, visitors' ratings, and the content of the Web sites. The authors compared a large sample of Web site owners with population-wide samples on the Big Five dimensions of personality. Controlling for demographic differences, the average Web site owner reported being slightly less extraverted and more open to experience. Compared with various other samples, Web site owners did not generally differ on narcissism, self-monitoring, or self-esteem, but gender differences on these traits were often smaller in Web site owners. Self-other agreement was highest with Openness to Experience, but valid judgments of all Big Five dimensions were derived from Web sites providing rich information. Visitors made use of quantifiable features of the Web site to infer personality, and the cues they utilized partly corresponded to self-reported traits. Copyright 2006 APA, all rights reserved.

  15. Use of personal radiation protection tools and individual dosimetric monitoring in a sample of interventional cardiologists in France, 2005-2009

    International Nuclear Information System (INIS)

    Jacob, S.; Bertrand, A.; Laurier, D.; Bernier, M.O.; Scanff, P.

    2014-01-01

    Interventional cardiologists (ICs) are repeatedly exposed to scattered ionising radiation during the cardiac procedures they perform, and radiation protection is an important issue for these medical professionals. The use of radiation protection tools is particularly relevant to this population. SISERI (Systeme d'Information de la Surveillance de l'Exposition aux Rayonnement Ionisants, that is, an information system for monitoring exposure to ionising radiation) is a register that stores personal dosimeter readings for dosimetric monitoring. This paper, based on data for a sample of French ICs from the O'CLOC epidemiological study, aims to provide an overview of the use of radiation protection equipment and dosimetric devices reported by ICs in a specific questionnaire as well as the dosimetric information found in the SISERI database for this population. Material and Methods - Annual information on interventional cardiology activity for the period from 01/01/2005 to 31/12/2009 was collected in an occupational questionnaire. ICs were asked to report the frequency in which they used individual dosimeter and radiation protection tools (lead apron, thyroid shield, eye-wear or face shield, ceiling-suspended shield) as follows: never (0% of the time), occasionally ( 50%), always (100%). We retrieved their medical radiation exposure information (monitored status and monthly effective doses) from the SISERI database for the period 2005-2009. Results - Information for 132 ICs (mean age in 2005 = 46 ± 7 years) was available. All ICs reported routine use of lead aprons, in contrast to their occasional use of lead eye-wear or face shields. During the study period, 49% reported systematic use of personal dosimeters, and 21% more regular use. On the other hand, 18% never used a dosimeter during this period. The SISTERI database included 92% of our population, 73% of whom had complete annual dose monitoring in SISERI (corresponding to at least 11 months per year of recorded

  16. Development and Performance Characteristics of Personal Gamma Spectrometer for Radiation Monitoring Applications

    Directory of Open Access Journals (Sweden)

    Hye Min Park

    2016-06-01

    Full Text Available In this study, a personal gamma (γ spectrometer was developed for use in applications in various fields, such as homeland security and environmental radiation monitoring systems. The prototype consisted of a 3 × 3 × 20 mm3 Ce-doped Gd–Al–Ga–garnet (Ce:GAGG crystal that was coupled to a Si photomultiplier (SiPM to measure γ radiation. The γ spectrometer could be accessed remotely via a mobile device. At room temperature, the implemented Ce:GAGG-SiPM spectrometer achieved energy resolutions of 13.5%, 6.9%, 5.8%, and 2.3% for 133Ba at 0.356 MeV, 22Na at 0.511 MeV, 137Cs at 0.662 MeV, and 60Co at 1.33 MeV, respectively. It consumed only about 2.7 W of power, had a mass of just 340 g (including the battery, and measured only 5.0 × 7.0 cm2.

  17. Worker-specific exposure monitor and method for surveillance of workers

    International Nuclear Information System (INIS)

    Lovejoy, M.L.; Peeters, J.P.; Johnson, A.W.

    2000-01-01

    This invention relates to a person-specific monitor that provides sensor information regarding hazards to which the person is exposed and means to geolocate the person at the time of the exposure. The monitor also includes means to communicate with a remote base station. Information from the monitor can be downloaded at the base station for long term storage and analysis. The base station can also include means to recharge the monitor

  18. EVALUATION OF A PERSONAL NEPHELOMETER FOR HUMAN EXPOSURE MONITORING

    Science.gov (United States)

    Current particulate matter (PM) exposure studies are using continuous personal nephelometers (pDR-1000, MIE, Inc.) to measure human exposure to PM. The personal nephelometer is a passive sampler which uses light scattering technology to measure particles ranging in size from 0....

  19. In situ monitoring the growth of thin-film ZnS/Zn (S,O) bilayer on Cu-chalcopyrite for high performance thin film solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Saez-Araoz, R.; Abou-Ras, D. [Helmholtz-Zentrum Berlin fuer Materialien und Energie GmbH, Solar Energy Division, Glienicker Strasse 100, 14109 Berlin (Germany); Niesen, T.P. [AVANCIS GmbH and Co KG Otto-Hahn-Ring 6, 81739 Munich (Germany); Neisser, A.; Wilchelmi, K. [SULFURCELL Solartechnik GmbH Barbara-McClintock-Strasse 11, 12489 Berlin (Germany); Lux-Steiner, M.Ch. [Helmholtz-Zentrum Berlin fuer Materialien und Energie GmbH, Solar Energy Division, Glienicker Strasse 100, 14109 Berlin (Germany); Ennaoui, A. [Helmholtz-Zentrum Berlin fuer Materialien und Energie GmbH, Solar Energy Division, Glienicker Strasse 100, 14109 Berlin (Germany)], E-mail: ennaoui@helmholtz-berlin.de

    2009-02-02

    This paper highlights the crucial role that the control of the chemical bath deposition (CBD) process plays for buffer production of Cu-chalcopyrite solar-cell devices. ZnS/Zn (S,O) bilayer was deposited on CuInS{sub 2} (CIS) and Cu(In,Ga)(SSe){sub 2} (CIGSSe) and monitored using turbidity measurements of the solution. The results were correlated to the X-ray photoemission spectra of the samples obtained by interruption of the process at sequential stages. Two different feature regimes were distinguished: In the first stage, a heterogeneous reaction takes place on the absorber resulting in the formation of pure ZnS. The second stage of the process is homogeneous, and the in-situ turbidity measurement shows a loss in the transmission of light through the CBD solution. The measured ZnL3M45M45 Auger-peaks, during this second stage of the process, show a shift of the kinetic energy from pure ZnS to a solid-solution ZnS/ZnO ('Zn (S,O)') with decreasing amount of sulfur. These results are supported by the observations from Energy-filtered transmission electron microscopy. This paper also demonstrates that monitoring of the CBD process combined with the basic understanding using surface and interface analysis have contributed to improve the reproducibility and to enhance the photovoltaic performance of Cu-chalcopyrite thin-film solar modules.

  20. In situ monitoring the growth of thin-film ZnS/Zn (S,O) bilayer on Cu-chalcopyrite for high performance thin film solar cells

    International Nuclear Information System (INIS)

    Saez-Araoz, R.; Abou-Ras, D.; Niesen, T.P.; Neisser, A.; Wilchelmi, K.; Lux-Steiner, M.Ch.; Ennaoui, A.

    2009-01-01

    This paper highlights the crucial role that the control of the chemical bath deposition (CBD) process plays for buffer production of Cu-chalcopyrite solar-cell devices. ZnS/Zn (S,O) bilayer was deposited on CuInS 2 (CIS) and Cu(In,Ga)(SSe) 2 (CIGSSe) and monitored using turbidity measurements of the solution. The results were correlated to the X-ray photoemission spectra of the samples obtained by interruption of the process at sequential stages. Two different feature regimes were distinguished: In the first stage, a heterogeneous reaction takes place on the absorber resulting in the formation of pure ZnS. The second stage of the process is homogeneous, and the in-situ turbidity measurement shows a loss in the transmission of light through the CBD solution. The measured ZnL3M45M45 Auger-peaks, during this second stage of the process, show a shift of the kinetic energy from pure ZnS to a solid-solution ZnS/ZnO ('Zn (S,O)') with decreasing amount of sulfur. These results are supported by the observations from Energy-filtered transmission electron microscopy. This paper also demonstrates that monitoring of the CBD process combined with the basic understanding using surface and interface analysis have contributed to improve the reproducibility and to enhance the photovoltaic performance of Cu-chalcopyrite thin-film solar modules

  1. COMPASS: an Interoperable Personal Health System to Monitor and Compress Signals in Chronic Obstructive Pulmonary Disease

    Directory of Open Access Journals (Sweden)

    Thomas Hofer

    2015-11-01

    Full Text Available In the past years the progress on the mobile market has made possible an advancement in terms of telemedicine systems and definition of systems for monitoring chronic illnesses. The distribution of mobile devices in developed countries is increasing. Many of these devices are equipped with wireless standards including Bluetooth and the amount of sold Smartphones is constantly increasing. Our approach is oriented towards this market, using existing devices to enable in-home patient monitoring and even further to ubiquitious monitoring. The idea is to increase the quality of care, reduce costs and gather medical grade data, especially vital signs, with a resolution of minutes or even less, which is nowadays only possible in an ICU (Intensive Care Units. In this paper we will present the COMPASS personal health system (PHS platform, and how this platform enables Android devices to collect, analyze and send sensor data to an observation storage by means of interoperability standards. Furthermore, we will also present how this data can be compressed using advanced compressed sensing techniques and how to optimize these techniques with genetic algorithms to improve the RMSE of the reconstructed signal after compression. We also produce a preliminary evaluation of the algorithm against the state of the art algorithms for compressed sensing.

  2. Atmospheric corrosion Monitoring with Time-of-Wetness (TOW) sensor and Thin Film Electric Resistance (TFER) sensor

    International Nuclear Information System (INIS)

    Jung, Sung Won; Kim, Young Geun; Song, Hong Seok; Lee, Seung Min; Kho, Young Tai

    2002-01-01

    In this study, TOW sensor was fabricated with the same P. J. Serada's in NRC and was evaluated according to pollutant amount and wet/dry cycle. Laboratorily fabricated thin film electric resistance (TFER) probes were applied in same environment for the measurement of corrosion rate for feasibility. TOW sensor could not differentiate the wet and dry time especially at polluted environment like 3.5% NaCl solution. This implies that wet/dry time monitoring by means of TOW sensor need careful application on various environment. TFER sensor could produce instant atmospheric corrosion rate regardless of environment condition. And corrosion rate obtained by TFER sensor could be differentiated according to wet/dry cycle, wet/dry cycle time variation and solution chemistry. Corrosion behaviors of TFER sensor showed that corrosion could proceed even after wet cycle because of remained electrolyte at the surface

  3. Breath acetone monitoring by portable Si:WO3 gas sensors

    Science.gov (United States)

    Righettoni, Marco; Tricoli, Antonio; Gass, Samuel; Schmid, Alex; Amann, Anton; Pratsinis, Sotiris E.

    2013-01-01

    Breath analysis has the potential for early stage detection and monitoring of illnesses to drastically reduce the corresponding medical diagnostic costs and improve the quality of life of patients suffering from chronic illnesses. In particular, the detection of acetone in the human breath is promising for non-invasive diagnosis and painless monitoring of diabetes (no finger pricking). Here, a portable acetone sensor consisting of flame-deposited and in situ annealed, Si-doped epsilon-WO3 nanostructured films was developed. The chamber volume was miniaturized while reaction-limited and transport-limited gas flow rates were identified and sensing temperatures were optimized resulting in a low detection limit of acetone (~20 ppb) with short response (10–15 s) and recovery times (35–70 s). Furthermore, the sensor signal (response) was robust against variations of the exhaled breath flow rate facilitating application of these sensors at realistic relative humidities (80–90%) as in the human breath. The acetone content in the breath of test persons was monitored continuously and compared to that of state-of-the-art proton transfer reaction mass spectrometry (PTR-MS). Such portable devices can accurately track breath acetone concentration to become an alternative to more elaborate breath analysis techniques. PMID:22790702

  4. Individual identification of free hole and electron dynamics in CuIn{sub 1−x}Ga{sub x}Se{sub 2} thin films by simultaneous monitoring of two optical transitions

    Energy Technology Data Exchange (ETDEWEB)

    Okano, Makoto [Institute for Chemical Research, Kyoto University, Uji, Kyoto 611-0011 (Japan); Hagiya, Hideki; Sakurai, Takeaki; Akimoto, Katsuhiro [Institute of Applied Physics, University of Tsukuba, Tsukuba, Ibaraki 305-8573 (Japan); Shibata, Hajime; Niki, Shigeru [National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki 305-8568 (Japan); Kanemitsu, Yoshihiko, E-mail: kanemitu@scl.kyoto-u.ac.jp [Institute for Chemical Research, Kyoto University, Uji, Kyoto 611-0011 (Japan); Japan Science and Technology Agency, CREST, Kyoto University, Uji, Kyoto 611-0011 (Japan)

    2015-05-04

    The photocarrier dynamics of CuIn{sub 1−x}Ga{sub x}Se{sub 2} (CIGS) thin films were studied using white-light transient absorption (TA) measurements, as an understanding of this behavior is essential for improving the performance of solar cells composed of CIGS thin films. A characteristic double-peak structure due to the splitting of the valence bands in the CIGS was observed in the TA spectra under near-band-gap resonant excitation. From a comparison of the TA decay dynamics monitored at these two peaks, it was found that the slow-decay components of the electron and hole relaxation are on the nanosecond timescale. This finding is clear evidence of the long lifetimes of free photocarriers in polycrystalline CIGS thin films.

  5. Ferroelectric BaTiO3 thin films on Ti substrate fabricated using pulsed-laser deposition.

    Science.gov (United States)

    He, J; Jiang, J C; Liu, J; Collins, G; Chen, C L; Lin, B; Giurgiutiu, V; Guo, R Y; Bhalla, A; Meletis, E I

    2010-09-01

    We report on the fabrication of ferroelectric BaTiO3 thin films on titanium substrates using pulsed laser deposition and their microstructures and properties. Electron microscopy studies reveal that BaTiO3 films are composed of crystalline assemblage of nanopillars with average cross sections from 100 nm to 200 nm. The BaTiO3 films have good interface structures and strong adhesion with respect to Ti substrates by forming a rutile TiO2 intermediate layer with a gradient microstructure. The room temperature ferroelectric polarization measurements show that the as-deposited BTO films possess nearly the same spontaneous polarization as the bulk BTO ceramics indicating formation of ferroelectric domains in the films. Successful fabrication of such ferroelectric films on Ti has significant importance for the development of new applications such as structural health monitoring spanning from aerospace to civil infrastructure. The work can be extended to integrate other ferroelectric oxide films with various promising properties to monitor the structural health of materials.

  6. Characterization of casein and poly-l-arginine multilayer films

    Science.gov (United States)

    Szyk-Warszyńska, Lilianna; Kilan, Katarzyna; Socha, Robert P.

    2014-06-01

    Thin films containing casein appear to be a promising material for coatings used in the medical area to promote biomineralization. alfa- and beta-casein and poly-L-arginine multilayer films were formed by the layer-by layer technique and their thickness and mass were analyzed by ellipsometry and quartz crystal microbalance with dissipation monitoring (QCM-D). We investigated the effect of the type of casein used for the film formation and of the polyethyleneimine anchoring layer on the thickness and mass of adsorbed films. The analysis of the mass of films during their post-treatment with the solutions of various ionic strength and pH provided the information concerning films stability, while the XPS elemental analysis confirmed binding of calcium ions by the casein embedded in the multilayers.

  7. Co-sputtered optical films

    Energy Technology Data Exchange (ETDEWEB)

    Misiano, C; Simonetti, E [Selenia S.p.A., Rome (Italy)

    1977-06-01

    The co-sputtering of two dielectric materials with indices of refraction as widely different as possible has been investigated with the aim of obtaining both homogeneous films with an intermediate index of refraction and inhomogeneous films with predetermined profiles. An rf sputtering module is described which has been especially designed, with two separate cathodes and two independent tunable rf generators. The substrates are placed on a circular anode rotating underneath the two cathodes. So far mainly CeO/sub 2/, TiO2 and SiO/sub 2/ targets have been used. The deposition rate from each cathode and the total film thickness are determined by means of two quartz thickness monitors, sputtering compatible. Values obtained for the refractive index and optical thickness are reported, as well as repeatability, mechanical and chemical characteristics, reliability and high power optical radiation resistance. Finally, results obtained on optical components of practical interest are discussed.

  8. Radioactive surface contamination monitors

    International Nuclear Information System (INIS)

    Aoyama, Kei; Minagoshi, Atsushi; Hasegawa, Toru

    1994-01-01

    To reduce radiation exposure and prevent contamination from spreading, each nuclear power plant has established a radiation controlled area. People and articles out of the controlled area are checked for the surface contamination of radioactive materials with surface contamination monitors. Fuji Electric has repeatedly improved these monitors on the basis of user's needs. This paper outlines typical of a surface contamination monitor, a personal surface contamination monitor, an article surface contamination monitor and a laundry monitor, and the whole-body counter of an internal contamination monitor. (author)

  9. Self-Monitoring and the Metatraits.

    Science.gov (United States)

    Wilmot, Michael P; DeYoung, Colin G; Stillwell, David; Kosinski, Michal

    2016-06-01

    Prior attempts at locating self-monitoring within general taxonomies of personality traits have largely proved unsuccessful. However, past research has typically neglected (a) the bidimensionality of the Self-Monitoring Scale and (b) the hierarchical nature of personality. The objective of this study was to test hypotheses that the two self-monitoring factors are located at the level of the metatraits. Using data from two large multi-informant samples, one community (Sample 1: N = 552, Mage  = 51.26, 61% female; NPeers  = 1,551, Mage  = 48.61, 37% female) and one online (Sample 2: N = 3,726, Mage  = 24.89, 59% female; NPeers  = 17,868, Mage  = 26.23, 64% female), confirmatory factor analysis was used to test the hypotheses. Results confirmed hypotheses that acquisitive self-monitoring would have a strong positive relation to metatrait Plasticity, whereas protective self-monitoring would have a moderate negative relation to metatrait Stability. In both samples, constraining the correlation between acquisitive self-monitoring and Plasticity to unity did not alter model fit indices, indicating that the two putatively distinct constructs are identical. Findings have wide-ranging implications, including integration of the construct of self-monitoring into the mainstream of personality research, as the latter moves toward the development of broad explanatory theories. © 2015 Wiley Periodicals, Inc.

  10. A non-contact high resolution piezoelectric film based sensor for monitoring breathing during sleep

    Science.gov (United States)

    Johnston, Robert; Nakano, Katsuya; Fujita, Kento; Misaki, Shinya; Fujii, Hiroyuki; Misaki, Yukinori

    2017-07-01

    Currently, research for measuring human breathing during sleep is actively being conducted into using technologies that include piezoelectric, ultrasonic, microwave and infrared rays. But various problems have led to not many practical applications. As such, it was decided to develop a PVDF (PolyVinylidene DiFluoride) based non-contact high resolution sensor for monitoring a subject's breathing as they sleep. Development of the high resolution respiration sensor was possible through the use of PVDF piezoelectric film and the development of a new sensor configuration. Although there was already an existing respiration sensor research resulting product available, is weak signal strength made it very sensitive to noise and difficult to measure respiration accurately. As such, complicated circuits and signal processing were needed. A new high resolution breathing sensor was developed with greater signal strength and with just the use of some simple circuits and signal processing, was able to accurately measure subject breathing. Also due to the greater signal strength, it became possible to measure both heart rate and respiration rate simultaneously.

  11. Using Film to Teach Authentic Leadership

    Science.gov (United States)

    Scott, Meagan; Weeks, Penny Pennington

    2016-01-01

    Utilizing film as a teaching tool in a personal leadership development course helped undergraduate students synthesize authentic leadership concepts. "Iron Jawed Angels" facilitated the culminating lesson as students applied course concepts to an observed leader. Three objectives guided the final lesson: (a) critique Alice Paul's…

  12. Brain Activation in Response to Personalized Behavioral and Physiological Feedback From Self-Monitoring Technology: Pilot Study.

    Science.gov (United States)

    Whelan, Maxine E; Morgan, Paul S; Sherar, Lauren B; Kingsnorth, Andrew P; Magistro, Daniele; Esliger, Dale W

    2017-11-08

    The recent surge in commercially available wearable technology has allowed real-time self-monitoring of behavior (eg, physical activity) and physiology (eg, glucose levels). However, there is limited neuroimaging work (ie, functional magnetic resonance imaging [fMRI]) to identify how people's brains respond to receiving this personalized health feedback and how this impacts subsequent behavior. Identify regions of the brain activated and examine associations between activation and behavior. This was a pilot study to assess physical activity, sedentary time, and glucose levels over 14 days in 33 adults (aged 30 to 60 years). Extracted accelerometry, inclinometry, and interstitial glucose data informed the construction of personalized feedback messages (eg, average number of steps per day). These messages were subsequently presented visually to participants during fMRI. Participant physical activity levels and sedentary time were assessed again for 8 days following exposure to this personalized feedback. Independent tests identified significant activations within the prefrontal cortex in response to glucose feedback compared with behavioral feedback (Pbrain activation when compared with behavior. Participants reduced time spent sedentary at follow-up. Research on deploying behavioral and physiological feedback warrants further investigation. ©Maxine E Whelan, Paul S Morgan, Lauren B Sherar, Andrew P Kingsnorth, Daniele Magistro, Dale W Esliger. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 08.11.2017.

  13. Routine monitoring of eye dose; and reply

    Energy Technology Data Exchange (ETDEWEB)

    Palmer, K; Jeans, S P; Faulkner, K; Bardsley, R A; Love, H G

    1985-12-01

    This letter briefly reports the assessment at Papworth Hospital of the feasibility of monitoring eye doses of staff using a film badge worn on the shoulder in addition to the badge worn under the lead apron. For three consecutive months hand and eye (forehead) dose were monitored using TLDs, while shoulder and body dose, recorded under the lead apron, were measured with film badges. For the four doctors monitored, (two radiologists and two cardiologists) the shoulder badge somewhat overestimated the eye dose. In the case of nurses, the dose recorded by the shoulder badge was of a similar order to the TLD-recorded eye dose. The reply from the Christie Hospital at Manchester comments on the use of the shoulder badge and contends that the use of forehead dosemeters to measure eye dose is to be preferred whenever possible.

  14. A portable battery powered microfluidic impedance cytometer with smartphone readout: towards personal health monitoring.

    Science.gov (United States)

    Talukder, Niloy; Furniturewalla, Abbas; Le, Tuan; Chan, Matthew; Hirday, Shreyas; Cao, Xinnan; Xie, Pengfei; Lin, Zhongtian; Gholizadeh, Azam; Orbine, Steve; Javanmard, Mehdi

    2017-06-01

    We present a portable system for personalized blood cell counting consisting of a microfluidic impedance cytometer and portable analog readout electronics, feeding into an analog-to-digital converter (ADC), and being transmitted via Bluetooth to a user-accessible mobile application. We fabricated a microfluidic impedance cytometer with a novel portable analog readout. The novel design of the analog readout, which consists of a lock-in-amplifier followed by a high-pass filter stage for subtraction of drift and DC offset, and a post-subtraction high gain stage, enables detection of particles and cells as small as 1 μm in diameter, despite using a low-end 8-bit ADC. The lock-in-amplifier and the ADC were set up to receive and transmit data from a Bluetooth module. In order to initiate the system, as well as to transmit all of the data, a user friendly mobile application was developed, and a proof-of-concept trial was run on a blood sample. Applications such as personalized health monitoring require robust device operation and resilience to clogging. It is desirable to avoid using channels comparable in size to the particles being detected thus requiring high levels of sensitivity. Despite using low-end off-the-shelf hardware, our sensing platform was capable of detecting changes in impedance as small as 0.032%, allowing detection of 3 μm diameter particles in a 300 μm wide channel. The sensitivity of our system is comparable to that of a high-end bench-top impedance spectrometer when tested using the same sensors. The novel analog design allowed for an instrument with a footprint of less than 80 cm 2 . The aim of this work is to demonstrate the potential of using microfluidic impedance spectroscopy for low cost health monitoring. We demonstrated the utility of the platform technology towards cell counting, however, our platform is broadly applicable to assaying wide panels of biomarkers including proteins, nucleic acids, and various cell types.

  15. Degradation of zinc oxide thin films in aqueous environment. Pt. II. Coated films

    Energy Technology Data Exchange (ETDEWEB)

    Rosa, L. de; Mitton, D.B.; Monetta, T.; Bellucci, F. [Naples Univ. (Italy). Dept. of Materials and Production Engineering; Springer, J. [Zentrum fuer Sonnenenergie- und Wasserstoff-Forschung Baden-Wuerttemberg (ZSW), Stuttgart (Germany)

    2001-12-01

    cn Part I of this research, the degradation mechanism of two different bare ZnO thin films was assessed. Degradation of the electrical properties of ZnO as well as changes in morphology were observed for both films. In the current paper, the degradation of zinc oxide thin films coated with protective acrylic paint is addressed during exposure to (i) an aqueous 3.5% NaCl solution at 85 C and (ii) a standard damp heat test at 85% R.H. and 85 C. Electrical and electrochemical techniques were employed to monitor zinc oxide degradation during exposure to the test environments. Electrochemical Impedance Spectroscopy was employed to investigate the delamination phenomena at the ZnO/coating interface and a simple equivalent circuit was developed to quantitatively measure the delamination ratio. The effect of different silane based adhesion promoters (glycidil-oxypropyl-trimethoxy-silane and aminopropyl-trimethoxy-silane) was also investigated. (orig.)

  16. Career Success: The Effects of Personality.

    Science.gov (United States)

    Lau, Victor P.; Shaffer, Margaret A.

    1999-01-01

    A model based on Bandura's Social Learning Theory proposes the following personality traits as determinants of career success: locus of control, self-monitoring, self-esteem, and optimism, along with job performance and person-to-environment fit. (SK)

  17. Radiation area monitoring by wireless-communicating area monitor with surveillance camera

    International Nuclear Information System (INIS)

    Shimura, Mitsuo; Kobayashi, Hiromitsu; Kitahara, Hideki; Kobayashi, Hironobu; Okamoto, Shinji

    2004-01-01

    Aiming at a dose reduction and a work efficiency improvement for nuclear power plants that have high dose regions, we have developed our system of wireless-communicating Area Monitor with Surveillance Camera, and have performed an on-site test. Now we are implementing this Area Monitor with Surveillance Camera for a use as a TV camera in the controlled-area, which enables a personal computer to simultaneously display two or more dose values and site live images on the screen. For the radiation detector of this Area Monitor System, our wireless-communicating dosimeter is utilized. Image data are transmitted via a wireless Local Area Network (LAN). As a test result, image transmission of a maximum of 20 frames per second has been realized, which shows that this concept is a practical application. Remote-site monitoring also has been realized from an office desk located within the non-controlled area, adopting a Japan's wireless phone system, PHS (Personal Handy Phone) for the transmission interface. (author)

  18. Properties of commercial PVC-films with respect to electron dosimetry

    International Nuclear Information System (INIS)

    Miller, A.; Liqing, X.

    1985-05-01

    The properties of three commercially available polyvinyl chloride (PVC) film supplies and one made without additives were tested with respects to their application as routine dose monitors at electron accelerators. Dose fractionation was found to increase the response and the post-irradiation heat treatment was very critical for some of the films. (author)

  19. Neurophysiological evidence of impaired self-monitoring in schizotypal personality disorder and its reversal by dopaminergic antagonism.

    Science.gov (United States)

    Rabella, Mireia; Grasa, Eva; Corripio, Iluminada; Romero, Sergio; Mañanas, Miquel Àngel; Antonijoan, Rosa M; Münte, Thomas F; Pérez, Víctor; Riba, Jordi

    2016-01-01

    Schizotypal personality disorder (SPD) is a schizophrenia-spectrum disorder characterized by odd or bizarre behavior, strange speech, magical thinking, unusual perceptual experiences, and social anhedonia. Schizophrenia proper has been associated with anomalies in dopaminergic neurotransmission and deficits in neurophysiological markers of self-monitoring, such as low amplitude in cognitive event-related brain potentials (ERPs) like the error-related negativity (ERN), and the error positivity (Pe). These components occur after performance errors, rely on adequate fronto-striatal function, and are sensitive to dopaminergic modulation. Here we postulated that analogous to observations in schizophrenia, SPD individuals would show deficits in self-monitoring, as measured by the ERN and the Pe. We also assessed the capacity of dopaminergic antagonists to reverse these postulated deficits. We recorded the electroencephalogram (EEG) from 9 SPD individuals and 12 healthy controls in two separate experimental sessions while they performed the Eriksen Flanker Task, a classical task recruiting behavioral monitoring. Participants received a placebo or 1 mg risperidone according to a double-blind randomized design. After placebo, SPD individuals showed slower reaction times to hits, longer correction times following errors and reduced ERN and Pe amplitudes. While risperidone impaired performance and decreased ERN and Pe in the control group, it led to behavioral improvements and ERN amplitude increases in the SPD individuals. These results indicate that SPD individuals show deficits in self-monitoring analogous to those in schizophrenia. These deficits can be evidenced by neurophysiological measures, suggest a dopaminergic imbalance, and can be reverted by dopaminergic antagonists.

  20. To monitor or not to monitor?: editorial

    International Nuclear Information System (INIS)

    Johns, T.F.

    1988-01-01

    After a brief discussion about results for occupational exposure in New Zealand and the UK, a short editorial raises a number of questions about personal dosimetry practice. These questions include whether the right people are being monitored and whether less attention should be paid to the monitoring of certain groups of workers who are occupationally exposed to external beta/gamma radiation, and more to the monitoring of workers or members of the general public who are exposed to higher doses from radon daughters, so as to focus attention on the areas where the largest savings in collective dose could be achieved. (U.K.)

  1. Real-Time Personalized Monitoring to Estimate Occupational Heat Stress in Ambient Assisted Working

    Directory of Open Access Journals (Sweden)

    Pablo Pancardo

    2015-07-01

    Full Text Available Ambient Assisted Working (AAW is a discipline aiming to provide comfort and safety in the workplace through customization and technology. Workers’ comfort may be compromised in many labor situations, including those depending on environmental conditions, like extremely hot weather conduces to heat stress. Occupational heat stress (OHS happens when a worker is in an uninterrupted physical activity and in a hot environment. OHS can produce strain on the body, which leads to discomfort and eventually to heat illness and even death. Related ISO standards contain methods to estimate OHS and to ensure the safety and health of workers, but they are subjective, impersonal, performed a posteriori and even invasive. This paper focuses on the design and development of real-time personalized monitoring for a more effective and objective estimation of OHS, taking into account the individual user profile, fusing data from environmental and unobtrusive body sensors. Formulas employed in this work were taken from different domains and joined in the method that we propose. It is based on calculations that enable continuous surveillance of physical activity performance in a comfortable and healthy manner. In this proposal, we found that OHS can be estimated by satisfying the following criteria: objective, personalized, in situ, in real time, just in time and in an unobtrusive way. This enables timely notice for workers to make decisions based on objective information to control OHS.

  2. Influence of p H on optical properties of nano structure sol-gel-derived silica films

    International Nuclear Information System (INIS)

    Heshmatpuor, F.; Adelkhani, H.; Nahavandi, M.; Noorbakhsh Shourabadi, M.

    2006-01-01

    Sol-gel derived silica films were fabricated by dip-coating onto glass microscope substrates. Film properties such as transmission and surface morphology were monitored as function of dip speed and sol p H. Film transmission was increased with increasing of p H in visible range. The surface morphology of films were investigated with scanning electron microscopy.

  3. A novel in-line NIR spectroscopy application for the monitoring of tablet film coating in an industrial scale process.

    Science.gov (United States)

    Möltgen, C-V; Puchert, T; Menezes, J C; Lochmann, D; Reich, G

    2012-04-15

    Film coating of tablets is a multivariate pharmaceutical unit operation. In this study an innovative in-line Fourier-Transform Near-Infrared Spectroscopy (FT-NIRS) application is described which enables real-time monitoring of a full industrial scale pan coating process of heart-shaped tablets. The tablets were coated with a thin hydroxypropyl methylcellulose (HPMC) film of up to approx. 28 μm on the tablet face as determined by SEM, corresponding to a weight gain of 2.26%. For a better understanding of the aqueous coating process the NIR probe was positioned inside the rotating tablet bed. Five full scale experimental runs have been performed to evaluate the impact of process variables such as pan rotation, exhaust air temperature, spray rate and pan load and elaborate robust and selective quantitative calibration models for the real-time determination of both coating growth and tablet moisture content. Principal Component (PC) score plots allowed each coating step, namely preheating, spraying and drying to be distinguished and the dominating factors and their spectral effects to be identified (e.g. temperature, moisture, coating growth, change of tablet bed density, and core/coat interactions). The distinct separation of HPMC coating growth and tablet moisture in different PCs enabled a real-time in-line monitoring of both attributes. A PLS calibration model based on Karl Fischer reference values allowed the tablet moisture trajectory to be determined throughout the entire coating process. A 1-latent variable iPLS weight gain calibration model with calibration samples from process stages dominated by the coating growth (i.e. ≥ 30% of the theoretically applied amount of coating) was sufficiently selective and accurate to predict the progress of the thin HPMC coating layer. At-line NIR Chemical Imaging (NIR-CI) in combination with PLS Discriminant Analysis (PLSDA) verified the HPMC coating growth and physical changes at the core/coat interface during the initial

  4. Study on the characteristics of insight dental x-ray film

    International Nuclear Information System (INIS)

    Song, Young Han; Lee, Wan; Lee, Byung Do

    2003-01-01

    To investigate the characteristics of the newly marketed, Insight dental X-ray film. Kodak Ultraspeed (DF-58), E-speed, Agfa Dentus M2, and Kodak Insight (IP-21) films were radiographed using a Trophy intra-oral radiographic machine. 10 step exposure times were prepared and each step exposure was monitored using a FH 40G (ESM Eberline Instruments) dosimeter for each of the 4 types of intra-oral film. All films were manually processed and the radiographic densities at 6 site of each processed film were measured, and the characteristic curves of each of the 4 types intra-oral films were created utilizing these dosimetric data and radiographic densities, based on ISO 5779. The film contrast, speed, and base plus fog density of Insight film were compared with those of the 3 other films examined in this experiment. E-speed film showed greatest average gradients followed by Insight film. E-speed and Ultraspeed film showed great average gradients at low density levels. Insight film showed the fastest speed followed by E-speed, Dentus M2 and Ultraspeed film. Dentus M2 film showed greatest base plus fog density level followed by Insight film. Kodak Insight film showed fastest film speed with comparable film contrast on characteristic curve.

  5. Understanding of electrochemical and structural changes of polypyrrole/polyethylene glycol composite films in aqueous solution

    Energy Technology Data Exchange (ETDEWEB)

    Pirvu, Cristian, E-mail: c_pirvu@chim.pub.ro [University Polytechnic of Bucharest, Faculty of Applied Chemistry and Materials Science, 1-7 Polizu, 011061 Bucharest (Romania); Manole, Claudiu Constantin; Stoian, Andrei Bogdan; Demetrescu, Ioana [University Polytechnic of Bucharest, Faculty of Applied Chemistry and Materials Science, 1-7 Polizu, 011061 Bucharest (Romania)

    2011-11-30

    Highlights: > Electrochemical monitoring of PPy and PPy-PEG films over immersion time. > Electrochemical and surface analysis showed that PEG improves the stability of PPy films. > Mott-Schottky analysis reveals p-type conductance for both films. > In situ AFM analysis sustains electrochemical behaviour. > A model of PPy and PPy-PEG films behaviour during immersion was elaborated. - Abstract: Electrochemical monitoring of electrical and structural changes of both PPy and PPy-PEG films electrochemical deposited, in order to highlight if the structural stability offered by PEG has an influence on electrical properties and stability in aqueous solution over immersion time was investigated. Electrochemical analysis suggests that PPy-PEG film inserts cations easier than PPy film for a short immersion time probably due to ability of PEG to form complexes with metal cations. The FTIR spectra showed that the PEG incorporation decreases the rate of PPy overoxidation probably by restraining the electron release and by rendering O{sub 2} inaccessible to PPy. Mott-Schottky analysis based on capacitance measurement reveal p-type conductance for both films. The in situ AFM analysis sustains electrochemical behaviour and has permitted elaboration of a model of PPy and PPy-PEG films behaviour during immersion in testing solution.

  6. Measurements of reciprocity law failure in green-sensitive X-ray films.

    Science.gov (United States)

    Arnold, B A; Eisenberg, H; Bjärngard, B E

    1978-02-01

    Reciprocity law failure was measured for four brands of medical x-ray films exposed with intensifying screens. Three of the films are green light-sensitized for use in combination with green light-emitting rare-earth screens. These films showed larger reciprocity failure effects than one conventional blue-sensitive film, Dupont Cronex-2. Development conditions had a small effect on reciprocity failure. As part of the investigation, a detector was constructed with a response that accurately monitors the light emission from the double screen-cassette combination over a wide range of x-ray photon energies.

  7. Gettering of carbon dioxide by erbium thin films

    International Nuclear Information System (INIS)

    Mehrhoff, T.K.

    1980-01-01

    The interaction of carbon dioxide and erbium thin films is characterized for temperatures in the region of 300 to 900 0 C and partial pressure of carbon dioxide near 5 x 10 -7 Torr. Dynamic film pumping speeds were measured against a mercury diffusion pump of known pumping speed and conductance. A quadrupole mass spectrometer was used to monitor the carbon dioxide flow which originated from a calibrated leak in the 10 -6 standard cm 3 /s range. Data reduction was via a dedicated minicomputer with associated printer/plotter. Temperature ramp experiments with thin erbium films indicated a significant reaction above 300 0 C. The reaction was preceded by the desorption of water vapor, hydrogen and nitrogen and/or carbon monoxide from the film surface

  8. Prediction of UV spectra and UV-radiation damage in actual plasma etching processes using on-wafer monitoring technique

    International Nuclear Information System (INIS)

    Jinnai, Butsurin; Fukuda, Seiichi; Ohtake, Hiroto; Samukawa, Seiji

    2010-01-01

    UV radiation during plasma processing affects the surface of materials. Nevertheless, the interaction of UV photons with surface is not clearly understood because of the difficulty in monitoring photons during plasma processing. For this purpose, we have previously proposed an on-wafer monitoring technique for UV photons. For this study, using the combination of this on-wafer monitoring technique and a neural network, we established a relationship between the data obtained from the on-wafer monitoring technique and UV spectra. Also, we obtained absolute intensities of UV radiation by calibrating arbitrary units of UV intensity with a 126 nm excimer lamp. As a result, UV spectra and their absolute intensities could be predicted with the on-wafer monitoring. Furthermore, we developed a prediction system with the on-wafer monitoring technique to simulate UV-radiation damage in dielectric films during plasma etching. UV-induced damage in SiOC films was predicted in this study. Our prediction results of damage in SiOC films shows that UV spectra and their absolute intensities are the key cause of damage in SiOC films. In addition, UV-radiation damage in SiOC films strongly depends on the geometry of the etching structure. The on-wafer monitoring technique should be useful in understanding the interaction of UV radiation with surface and in optimizing plasma processing by controlling UV radiation.

  9. NILAI PENDIDIKAN KARAKTER BERBASIS KEARIFAN LOKAL DALAM FILM INDIE BANYUMAS

    Directory of Open Access Journals (Sweden)

    Teguh Trianton

    2013-03-01

    Full Text Available Film is entertainment for people who are able to penetrate the social class boundaries. The ability to reach various segments of the film class, film making has the potential to affect masyarakt audience. Strategic value of the film not only serves as entertainment, the film has the potential as a medium of education, which can effectively communicate educational messages, and even be able to influence a person's behavior. This is the one of the spirit for student filmmakers in Purbalingga, Banyumas, Cilacap and Banjarnegara continues to be creative by producing indie films. Film is the medium for the message menyampaiakn, storytelling and expression. As with any work of literature (novels, short stories, drama, theater, in the film there is also a story, the scene, dialogue, scene, conflict, character, character, and setting. One of the benefits is being able to visualize movie various human characters so that it can easily intervene or influence the minds of the audience. This is where the potential effectiveness of the film in instilling moral values as part of the educational aspect of the nation's character.

  10. Combined micro-droplet and thin-film-assisted pre-concentration of lead traces for on-line monitoring using anodic stripping voltammetry.

    Science.gov (United States)

    Belostotsky, Inessa; Gridin, Vladimir V; Schechter, Israel; Yarnitzky, Chaim N

    2003-02-01

    An improved analytical method for airborne lead traces is reported. It is based on using a Venturi scrubber sampling device for simultaneous thin-film stripping and droplet entrapment of aerosol influxes. At least threefold enhancement of the lead-trace pre-concentration is achieved. The sampled traces are analyzed by square-wave anodic stripping voltammetry. The method was tested by a series of pilot experiments. These were performed using contaminant-controlled air intakes. Reproducible calibration plots were obtained. The data were validated by traditional analysis using filter sampling. LODs are comparable with the conventional techniques. The method was successfully applied to on-line and in situ environmental monitoring of lead.

  11. Combined micro-droplet and thin-film-assisted pre-concentration of lead traces for on-line monitoring using anodic stripping voltammetry

    Energy Technology Data Exchange (ETDEWEB)

    Belostotsky, Inessa; Gridin, Vladimir V.; Schechter, Israel; Yarnitzky, Chaim N. [Department of Chemistry, Technion Israel Institute of Technology, 32000, Haifa (Israel)

    2003-02-01

    An improved analytical method for airborne lead traces is reported. It is based on using a Venturi scrubber sampling device for simultaneous thin-film stripping and droplet entrapment of aerosol influxes. At least threefold enhancement of the lead-trace pre-concentration is achieved. The sampled traces are analyzed by square-wave anodic stripping voltammetry. The method was tested by a series of pilot experiments. These were performed using contaminant-controlled air intakes. Reproducible calibration plots were obtained. The data were validated by traditional analysis using filter sampling. LODs are comparable with the conventional techniques. The method was successfully applied to on-line and in situ environmental monitoring of lead. (orig.)

  12. Monitoring and dose recording for the individual

    International Nuclear Information System (INIS)

    1988-01-01

    This document specifies the conditions under which monitoring of individuals is required. For workers identified as Atomic Radiation Workers, determination of dose or exposure must be made. In circumstances where personal monitoring techniques are impractical, doses and exposures may be estimated by non-personal monitoring techniques. For workers not identified as Atomic Radiation Workers, licensees must be able to demonstrate that there is no reasonable potential for accumulating radiation doses or exposures in excess of regulatory limits. (L.L.)

  13. Al-Sn doped ZnO thin film nanosensor for monitoring NO2 concentration

    Directory of Open Access Journals (Sweden)

    G.S. Hikku

    2017-07-01

    Full Text Available The metal oxide semiconductor gas sensor technology is robust and has quick response times. In this work, aluminium and tin co-doped zinc oxide (ASZO thin films were synthesized by a sol–gel dip-coating process as sensors for the greenhouse gas nitrogen dioxide (NO2. The prepared ASZO thin films were characterized using such techniques as X-ray diffraction (XRD, scanning electron microscopy (SEM, atomic force microscopy (AFM and photoluminescence (PL emission studies in order to analyze the elemental confirmation, particle size, surface roughness and optical emission properties, respectively. The XRD data reveals the hexagonal structure of ASZO and that the preferential orientation is along 2θ = 36.19°. SEM images of the ASZO thin film exhibit rod-like formations of ASZO on the substrate. The ASZO films show enhanced sensing behaviour, sensing NO2 gas even at 2 ppm at an operating temperature of 170 °C. The response and recovery times were determined to be 30 and 20 s, respectively.

  14. Mechanical Robustness and Hermeticity Monitoring for MEMS Thin Film Encapsulation

    NARCIS (Netherlands)

    Santagata, F.

    2011-01-01

    Many Micro-Electro-Mechanical-Systems (MEMS) require encapsulation, to prevent delicate sensor structures being exposed to external perturbations such as dust, humidity, touching, and gas pressure. An upcoming and cost-effective way of encapsulation is zero-level packaging or thin-film

  15. Optical monitoring of CH3NH3PbI3 thin films upon atmospheric exposure

    International Nuclear Information System (INIS)

    Ghimire, Kiran; Zhao, Dewei; Cimaroli, Alex; Ke, Weijun; Yan, Yanfa; Podraza, Nikolas J

    2016-01-01

    CH 3 NH 3 PbI 3 perovskite films of interest for photovoltaic (PV) devices have been prepared by (i) vapor deposition and (ii) solution processing. Complex dielectric function ( ε   =   ε 1   +  i ε 2 ) spectra and structural parameters of the films have been extracted using near infrared to ultraviolet spectroscopic ellipsometry. In situ real time spectroscopic ellipsometry (RTSE) over a 48 h period has been performed on vapor deposited CH 3 NH 3 PbI 3 after the deposition in normal atmospheric laboratory ambient conditions. Analysis of RTSE data for vapor deposited CH 3 NH 3 PbI 3 film prepared under un-optimized conditions identifies phase segregated PbI 2 and CH 3 NH 3 I at the substrate/film interface and unreacted PbI 2 and CH 3 NH 3 I on the film surface. This analysis also provides the time dependence of the effective thicknesses of perovskite film, unreacted components, and phase segregated layers to track CH 3 NH 3 PbI 3 decomposition. (paper)

  16. Electronic personal dosemeters

    International Nuclear Information System (INIS)

    Marshall, T.O.; Bartlett, D.T.; Burgess, P.H.; Cranston, C.S.; Higginbottom, D.J.; Sutton, K.W.

    1990-01-01

    Personal dosimetry services approved by their national authorities for category A workers, invariably use passive dosemeters incorporating photographic film or thermoluminescent detectors. However, the performance characteristics of electronic dosemeters has improved substantially over the past decade to such an extent that in the opening lecture of the Solid State Dosimetry Conference at Oxford in 1986 the development of an electronic 'smart card' based on a silicon detector was briefly discussed. This idea has been taken up and at least one development programme is in progress aimed at the production of an electronic dosemeter suitable for use as a legal device. The more important performance requirements of personal dosemeters for this purpose are discussed and the earlier electronic dosemeter designs and the latest devices under development to meet this specification are compared. (author)

  17. Family structure and dynamics in DePalma's horror films.

    Science.gov (United States)

    Gordon, N G

    1983-01-01

    An analysis of the familial relationships in Brian DePalma's five major horror films reveals a persistent unconscious fantasy formation involving the nuclear family. These single-parent, only-child families are all tragically destroyed because of an inability to adequately mourn the absent parent. Although the asexual young adults in the films are spared the completely disastrous effects of madness and violence, they are still psychologically traumatized. This hidden subtextual theme involving the family parallels DePalma's bleak view of authority figures outside the home, as well as American society in general. Adequate identity formation requires that people both inside and outside the family accept the adolescent as a separate person. The grim psychological truth threading its way throughout DePalma's horror films is that these young adults are psychically devastated by the effects of a primitive, fused symbiotic relationship in interaction with a society that does not provide an adequate role for the developing person. Consequently, their attempt to psychologically move outside the family, which includes the maturation of their sexuality, results in the destruction of the family itself.

  18. Documentation of scintigraphic examinations using miniature format colour films and an instant slide system

    International Nuclear Information System (INIS)

    Deininger, H.K.; Schmidt, C.

    1985-01-01

    A new 35 mm format instant film (Polachrome CS 135) was investigated for suitability in comparison to established conventional colour miniature films. Differences were found, depending on whether the photographic colour material was used for slides or paper prints. Optimum colour results were obtained in monitor photography. The material also proved useful for the recording of paper prints of colour scans, since these were mainly intended for the purpose of transferring the diagnostic findings as a complement to the written report. Priority was therefore given to the immediate availability of the copy, which may be of importance in monitor photography as well. In this respect the new polaroid instant miniature film is clearly superior to those 35 mm colour films that have been used in nuclear medicine up to now. (orig.) [de

  19. Embodying Others in Immersive Virtual Reality: Electro-Cortical Signatures of Monitoring the Errors in the Actions of an Avatar Seen from a First-Person Perspective.

    Science.gov (United States)

    Pavone, Enea Francesco; Tieri, Gaetano; Rizza, Giulia; Tidoni, Emmanuele; Grisoni, Luigi; Aglioti, Salvatore Maria

    2016-01-13

    Brain monitoring of errors in one's own and other's actions is crucial for a variety of processes, ranging from the fine-tuning of motor skill learning to important social functions, such as reading out and anticipating the intentions of others. Here, we combined immersive virtual reality and EEG recording to explore whether embodying the errors of an avatar by seeing it from a first-person perspective may activate the error monitoring system in the brain of an onlooker. We asked healthy participants to observe, from a first- or third-person perspective, an avatar performing a correct or an incorrect reach-to-grasp movement toward one of two virtual mugs placed on a table. At the end of each trial, participants reported verbally how much they embodied the avatar's arm. Ratings were maximal in first-person perspective, indicating that immersive virtual reality can be a powerful tool to induce embodiment of an artificial agent, even through mere visual perception and in the absence of any cross-modal boosting. Observation of erroneous grasping from a first-person perspective enhanced error-related negativity and medial-frontal theta power in the trials where human onlookers embodied the virtual character, hinting at the tight link between early, automatic coding of error detection and sense of embodiment. Error positivity was similar in 1PP and 3PP, suggesting that conscious coding of errors is similar for self and other. Thus, embodiment plays an important role in activating specific components of the action monitoring system when others' errors are coded as if they are one's own errors. Detecting errors in other's actions is crucial for social functions, such as reading out and anticipating the intentions of others. Using immersive virtual reality and EEG recording, we explored how the brain of an onlooker reacted to the errors of an avatar seen from a first-person perspective. We found that mere observation of erroneous actions enhances electrocortical markers of

  20. Study of a Particle Based Films Cure Process by High-Frequency Eddy Current Spectroscopy

    Directory of Open Access Journals (Sweden)

    Iryna Patsora

    2016-12-01

    Full Text Available Particle-based films are today an important part of various designs and they are implemented in structures as conductive parts, i.e., conductive paste printing in the manufacture of Li-ion batteries, solar cells or resistive paste printing in IC. Recently, particle based films were also implemented in the 3D printing technique, and are particularly important for use in aircraft, wind power, and the automotive industry when incorporated onto the surface of composite structures for protection against damages caused by a lightning strike. A crucial issue for the lightning protection area is to realize films with high homogeneity of electrical resistance where an in-situ noninvasive method has to be elaborated for quality monitoring to avoid undesirable financial and time costs. In this work the drying process of particle based films was investigated by high-frequency eddy current (HFEC spectroscopy in order to work out an automated in-situ quality monitoring method with a focus on the electrical resistance of the films. Different types of particle based films deposited on dielectric and carbon fiber reinforced plastic substrates were investigated in the present study and results show that the HFEC method offers a good opportunity to monitor the overall drying process of particle based films. Based on that, an algorithm was developed, allowing prediction of the final electrical resistance of the particle based films throughout the drying process, and was successfully implemented in a prototype system based on the EddyCus® HFEC device platform presented in this work. This prototype is the first solution for a portable system allowing HFEC measurement on huge and uneven surfaces.

  1. Transparent and Flexible Self-Charging Power Film and Its Application in a Sliding Unlock System in Touchpad Technology.

    Science.gov (United States)

    Luo, Jianjun; Tang, Wei; Fan, Feng Ru; Liu, Chaofeng; Pang, Yaokun; Cao, Guozhong; Wang, Zhong Lin

    2016-08-23

    Portable and wearable personal electronics and smart security systems are accelerating the development of transparent, flexible, and thin-film electronic devices. Here, we report a transparent and flexible self-charging power film (SCPF) that functions either as a power generator integrated with an energy storage unit or as a self-powered information input matrix. The SCPF possesses the capability of harvesting mechanical energy from finger motions, based on the coupling between the contact electrification and electrostatic induction effects, and meanwhile storing the generated energy. Under the fast finger sliding, the film can be charged from 0 to 2.5 V within 2094 s and discharge at 1 μA for approximately 1630 s. Furthermore, the film is able to identify personal characteristics during a sliding motion by recording the electric signals related to the person's individual bioelectricity, applied pressing force, sliding speed, and so on, which shows its potential applications in security systems in touchpad technology.

  2. Nanostructured hybrid films containing nanophosphor: Fabrication and electronic spectral properties

    Energy Technology Data Exchange (ETDEWEB)

    Camacho, S.A. [Instituto de Biociencias, Letras e Ciencias Exatas, UNESP - Univ Estadual Paulista, Rua Cristovao Colombo, 2265, 15054-000 Sao Jose do Rio Preto, SP (Brazil); Aoki, P.H.B.; Constantino, C.J.L. [Faculdade de Ciencias e Tecnologia, UNESP - Univ Estadual Paulista, Rua Roberto Simonsen, 305, 19060-900 Presidente Prudente, SP (Brazil); Aroca, R.F. [Materials and Surface Science Group, University of Windsor, Windsor, Ont., Canada N9B3P4 (Canada); Pires, A.M., E-mail: anapires@fct.unesp.br [Faculdade de Ciencias e Tecnologia, UNESP - Univ Estadual Paulista, Rua Roberto Simonsen, 305, 19060-900 Presidente Prudente, SP (Brazil)

    2012-11-15

    Highlights: Black-Right-Pointing-Pointer Hybrid film containing the cationic polyelectrolyte PAH and Y{sub 2}O{sub 3}: Er, Yb nanophosphor. Black-Right-Pointing-Pointer LbL film growth was monitored by absorbance x concentration in UV-Vis absorption. Black-Right-Pointing-Pointer FTIR indicated existence of secondary interactions between PAH - nanophosphor layers. Black-Right-Pointing-Pointer The morphology and the spatial distribution of the LbL film were analyzed by Raman. Black-Right-Pointing-Pointer We observed intense electronic emission lines from doping ions in the micro-Raman. - Abstract: The intensive research of the optical properties of rare-earth ions is due to the high quantum efficiency of their emission, very narrow bands, and excellent fluorescence monochromaticity. The photoluminescence data presented here show that the nanophosphor remains a green emitter in Layer-by-Layer (LbL) films leading to potential application in optical devices or biological labeling. The LbL technique, an established method for thin film fabrication with molecular architecture control, is used in the manufacture of a hybrid film containing the cationic polyelectrolyte poly (allylamine hydrochloride) (PAH) and Y{sub 2}O{sub 3}: Er, Yb nanophosphor. The spectroscopic properties of this luminescent nanomaterial are extracted from the spectral data of the powder, cast film and LbL films. The growth of the LbL film was monitored by absorbance versus concentration plots in ultraviolet-visible (UV-Vis) absorption spectroscopy. The presence of both PAH and nanophosphor in the LbL film was confirmed by Fourier transform infrared (FTIR) absorption spectroscopy. The FTIR data also ruled out the existence of chemical interactions between the PAH and nanophosphor layers, which means that secondary interactions (like Van der Waals forces) might be the driving forces for LbL film growth. The morphology and the spatial distribution of the LbL film components along the film surface were

  3. Human Nonverbal Behaviors, Empathy, and Film.

    Science.gov (United States)

    Wiggers, T. Thorne

    Nonverbal behavior is an important aspect of the film and is one of the several tools that a director uses to communicate to an audience the characters' feelings and relationships. By adding to this information their own personal responses, viewers often experience strong feelings. With reference to the social psychological research of nonverbal…

  4. Optical Waveguide Lightmode Spectroscopy (OWLS as a Sensor for Thin Film and Quantum Dot Corrosion

    Directory of Open Access Journals (Sweden)

    Jinke Tang

    2012-12-01

    Full Text Available Optical waveguide lightmode spectroscopy (OWLS is usually applied as a biosensor system to the sorption-desorption of proteins to waveguide surfaces. Here, we show that OWLS can be used to monitor the quality of oxide thin film materials and of coatings of pulsed laser deposition synthesized CdSe quantum dots (QDs intended for solar energy applications. In addition to changes in data treatment and experimental procedure, oxide- or QD-coated waveguide sensors must be synthesized. We synthesized zinc stannate (Zn2SnO4 coated (Si,TiO2 waveguide sensors, and used OWLS to monitor the relative mass of the film over time. Films lost mass over time, though at different rates due to variation in fluid flow and its physical effect on removal of film material. The Pulsed Laser Deposition (PLD technique was used to deposit CdSe QD coatings on waveguides. Sensors exposed to pH 2 solution lost mass over time in an expected, roughly exponential manner. Sensors at pH 10, in contrast, were stable over time. Results were confirmed with atomic force microscopy imaging. Limiting factors in the use of OWLS in this manner include limitations on the annealing temperature that maybe used to synthesize the oxide film, and limitations on the thickness of the film to be studied. Nevertheless, the technique overcomes a number of difficulties in monitoring the quality of thin films in-situ in liquid environments.

  5. Polymedication Electronic Monitoring System (POEMS) - a new technology for measuring adherence.

    Science.gov (United States)

    Arnet, Isabelle; Walter, Philipp N; Hersberger, Kurt E

    2013-01-01

    Reliable and precise measurement of patient adherence to medications is feasible by incorporating a microcircuitry into pharmaceutical packages of various designs, such that the maneuvers needed to remove a dose of drug are detected, time-stamped, and stored. The principle is called "electronic medication event monitoring" but is currently limited to the monitoring of a single drug therapy. Our aims were introducing a new technology; a clear, self-adhesive polymer film, with printed loops of conductive wires that can be affixed to multidrug punch cards for the electronic adherence monitoring of multiple medication regimens (Polymedication Electronic Monitoring System, POEMS), and illustrating potential benefits for patient care. We present a preliminary report with one patient experience. Our illustrative case was supplied with a pre-filled 7-day multiple medication punch card with unit-of-use doses for specific times of the day (six pills in the morning cavity, two pills in the evening cavity, and one pill in case of insomnia in the bedtime cavity), with the new electronic film affixed on it. The intake times over 1 week were extremely skewed (median intake hours at 2:00 pm for the morning doses and at 6:40 pm for the evening doses). After an intervention aimed at optimizing the timing adherence, the morning and evening intake hours became more balanced, with 42.3% of correct dosing intervals (±3 h) for drugs with twice daily intake (vs. 0% before the intervention). The electronic monitoring of the entire therapy revealed an intake pattern that would have remained undiscovered with any other device and allowed a personalized intervention to correct an inadequate medication intake behavior. POEMS may guide health professionals when they need to optimize a pharmacotherapy because of suspected insufficient adherence. Further, knowing the intake pattern of the entire pharmacotherapy can elucidate unreached clinical outcome, drug-drug interactions, and drug resistance

  6. Personal carbon monoxide exposures of preschool children in Helsinki, Finland - comparison to ambient air concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Alm, S.; Mukala, K.; Tittanen, P.; Jantunen, M.J. [KTL National Public Health Institute, Kuopio (Finland). Dept. of Environmental Health

    2001-07-01

    The associations of personal carbon monoxide (CO) exposures with ambient air CO concentrations measured at fixed monitoring sites, were studied among 194 children aged 3-6yr in four downtown and four suburban day-care centers in Helsinki, Finland. Each child carried a personal CO exposure monitor between 1 and 4 times for a time period of between 20 and 24h. CO concentrations at two fixed monitoring sites were measured simultaneously. The CO concentrations measured at the fixed monitoring sites were usually lower (mean maximum 8-h concentration: 0.9 and 2.6mgm{sup -3}) than the personal CO exposure concentrations (mean maximum 8-h concentration: 3.3mgm{sup -3}).The fixed site CO concentrations were poor predictors of the personal CO exposure concentrations. However, the correlations between the personal CO exposure and the fixed monitoring site CO concentrations increased (-0.03 -- -0.12 to 0.13-0.16) with increasing averaging times from 1 to 8h. Also, the fixed monitoring site CO concentrations explained the mean daily or weekly personal CO exposures of a group of simultaneously measured children better than individual exposure CO concentrations. This study suggests that the short-term CO personal exposure of children cannot be meaningfully assessed using fixed monitoring sites. (author)

  7. Smoothing of ZnO films by gas cluster ion beam

    International Nuclear Information System (INIS)

    Chen, H.; Liu, S.W.; Wang, X.M.; Iliev, M.N.; Chen, C.L.; Yu, X.K.; Liu, J.R.; Ma, K.; Chu, W.K.

    2005-01-01

    Planarization of wide-band-gap semiconductor ZnO surface is crucial for thin-film device performance. In this study, the rough initial surfaces of ZnO films deposited by r.f. magnetron sputtering on Si substrates were smoothed by gas cluster ion beams. AFM measurements show that the average surface roughness (R a ) of the ZnO films could be reduced considerably from 16.1 nm to 0.9 nm. Raman spectroscopy was used to monitor the structure of both the as-grown and the smoothed ZnO films. Rutherford back-scattering in combination with channeling effect was used to study the damage production induced by the cluster bombardment

  8. Slightly Conductive Transparent Films for Space Applications: Manufacturability and Durability

    Science.gov (United States)

    Uppala, N.; Griffin, J.; Vemulapalli, J.; Hambourger, P. D.

    2001-01-01

    Highly transparent, slightly conductive films of co-deposited indium tin oxide (ITO) and MgF, have possible applications for environmental protection of exterior surfaces of spacecraft. Reliable preparation of films with the desired sheet resistivity (approximately 10(exp 8) ohms/square) is difficult because the electrical properties of ITO-Mg F, are highly dependent on film composition. We have investigated the use of plasma emission monitoring to improve the reproducibility of films prepared by RF magnetron sputtering. While considerable improve ment was observed, it appears that some in-situ electrical or optica l characterization will be needed for reliable production coating wit h ITO-MgF,. We have also done further evaluation of a possibly undesi rable photoconductive effect previously observed in these films.

  9. A programme to rationalize film dosimetry by data processing

    International Nuclear Information System (INIS)

    Ritzenhoff, K.H.

    1976-01-01

    Plan to realize the following intentions for monitoring appr. 45,000 persons per month: 1) Extending the data bank with evaluation results to a universal personnel dose register covering all persons monitored, 2) comprising the individual rationalization measures in an extensive rationalization model of the procedures in a personnel dose measuring service by using EDP-systems. (orig./HP) [de

  10. Understanding of electrochemical and structural changes of polypyrrole/polyethylene glycol composite films in aqueous solution

    International Nuclear Information System (INIS)

    Pirvu, Cristian; Manole, Claudiu Constantin; Stoian, Andrei Bogdan; Demetrescu, Ioana

    2011-01-01

    Highlights: → Electrochemical monitoring of PPy and PPy-PEG films over immersion time. → Electrochemical and surface analysis showed that PEG improves the stability of PPy films. → Mott-Schottky analysis reveals p-type conductance for both films. → In situ AFM analysis sustains electrochemical behaviour. → A model of PPy and PPy-PEG films behaviour during immersion was elaborated. - Abstract: Electrochemical monitoring of electrical and structural changes of both PPy and PPy-PEG films electrochemical deposited, in order to highlight if the structural stability offered by PEG has an influence on electrical properties and stability in aqueous solution over immersion time was investigated. Electrochemical analysis suggests that PPy-PEG film inserts cations easier than PPy film for a short immersion time probably due to ability of PEG to form complexes with metal cations. The FTIR spectra showed that the PEG incorporation decreases the rate of PPy overoxidation probably by restraining the electron release and by rendering O 2 inaccessible to PPy. Mott-Schottky analysis based on capacitance measurement reveal p-type conductance for both films. The in situ AFM analysis sustains electrochemical behaviour and has permitted elaboration of a model of PPy and PPy-PEG films behaviour during immersion in testing solution.

  11. Plat du jour – Short Films!

    CERN Multimedia

    Claudia Marcelloni

    2014-01-01

    Next week, take a break from the cafeteria and have a ciné-lunch at the Globe!   How about if, for a change, you forgot your lunch meeting and went to the movies with your colleagues (or that person that you always wanted to ask out) right here on the CERN site? CERN will be hosting the next CineGlobe International Film Festival from 18 to 23 March in the Globe of Science and Innovation, with the theme "Beyond the Frontier". The 4th annual festival will see 66 short films "inspired by science" in competition, including fiction films as well as documentaries. From Tuesday 18 to Friday 21, special lunch sessions will take place from 12.30 p.m. to 1.30 p.m. Food will be available for purchase at the “Café Cinéma” tent next to the Globe. Special evenings: While the short film screenings are the heart of the festival, each year CineGlobe also organises compelling special events every night, from feature fil...

  12. Personalized medicine: genome, e-health and intelligent systems. Part 1. Genomics and monitoring of clinical data

    Directory of Open Access Journals (Sweden)

    B. A. Kobrinskii

    2017-01-01

    Full Text Available The transition to personalized medicine in practical terms should combine the solution of the genomics problems as the basis for possible diseases and phenotypic manifestations that are markers and early signs of emerging pathological changes. Most diseases have their first principles in childhood. Therefore, in all age groups, it is necessary to monitor the minimum deviations and their dynamics, use mobile devices for this purpose and accumulate the received data. Processing big data (Big Data will provide more informative information. On this basis it will be possible to identify analogs for targeted therapy in similar variants of diseases in large databases of publications on the problem of interest.

  13. Testing of CaSO-4:Dy in teflon discs as a thermoluminescent dosimetry material for personal monitoring of uranium mine and mill workers

    International Nuclear Information System (INIS)

    Boas, J.F.; Murray, A.; Young, J.G.; Johnston, P.N.

    1981-05-01

    Some studies of the spectroscopic and thermoluminescent properties of CaSO 4 :Dy are discussed. Measurements were also made in the field. Exposures measured using TLD, film and spot monitoring were in agreement, and these observations, together with measurements made at various heights above the ore stockpile have shown that CaSO 4 :Dy in teflon discs, shielded by 2mm of copper, give a reliable measure of the exposure at the appropriate position on the wearer's body. This exposure may then be converted into the dose equivalent for the whole body

  14. Dose monitoring in nuclear emergency

    International Nuclear Information System (INIS)

    Nan Hongjie; Yang Zhongping; Lei Xin

    2012-01-01

    In order to protect people from irradiation sickness and rebuild the radiation filed in nuclear emergency, personal and environmental dose need to be monitored. The application of TLD in dose monitoring is discussed in this paper. (authors)

  15. Recommending personally interested contents by text mining, filtering, and interfaces

    Science.gov (United States)

    Xu, Songhua

    2015-10-27

    A personalized content recommendation system includes a client interface device configured to monitor a user's information data stream. A collaborative filter remote from the client interface device generates automated predictions about the interests of the user. A database server stores personal behavioral profiles and user's preferences based on a plurality of monitored past behaviors and an output of the collaborative user personal interest inference engine. A programmed personal content recommendation server filters items in an incoming information stream with the personal behavioral profile and identifies only those items of the incoming information stream that substantially matches the personal behavioral profile. The identified personally relevant content is then recommended to the user following some priority that may consider the similarity between the personal interest matches, the context of the user information consumption behaviors that may be shown by the user's content consumption mode.

  16. Spark counting technique of alpha tracks on an aluminium oxide film

    International Nuclear Information System (INIS)

    Morishima, Hiroshige; Koga, Taeko; Niwa, Takeo; Kawai, Hiroshi

    1984-01-01

    We have tried to use aluminium oxide film as a neutron detector film with a spark counter for neutron monitoring in the mixed field of neutron and gamma-rays near a reactor. The merits of this method are that (1) aluminium oxide is good electric insulator, (2) any desired thickness of the film can be prepared, (3) chemical etching of the thin film can be dispensed with. The relation between spark counts and numbers of alpha-particles which entered the aluminium oxide film 1 μm thick was linear in the range of 10 5 -10 7 alpha-particles. The sensitivity(ratio of the spark counts to irradiated numbers of alpha-particles) was approximately 10 -3 . (author)

  17. Advanced Pulse Oximetry System for Remote Monitoring and Management

    Science.gov (United States)

    Pak, Ju Geon; Park, Kee Hyun

    2012-01-01

    Pulse oximetry data such as saturation of peripheral oxygen (SpO2) and pulse rate are vital signals for early diagnosis of heart disease. Therefore, various pulse oximeters have been developed continuously. However, some of the existing pulse oximeters are not equipped with communication capabilities, and consequently, the continuous monitoring of patient health is restricted. Moreover, even though certain oximeters have been built as network models, they focus on exchanging only pulse oximetry data, and they do not provide sufficient device management functions. In this paper, we propose an advanced pulse oximetry system for remote monitoring and management. The system consists of a networked pulse oximeter and a personal monitoring server. The proposed pulse oximeter measures a patient's pulse oximetry data and transmits the data to the personal monitoring server. The personal monitoring server then analyzes the received data and displays the results to the patient. Furthermore, for device management purposes, operational errors that occur in the pulse oximeter are reported to the personal monitoring server, and the system configurations of the pulse oximeter, such as thresholds and measurement targets, are modified by the server. We verify that the proposed pulse oximetry system operates efficiently and that it is appropriate for monitoring and managing a pulse oximeter in real time. PMID:22933841

  18. Dye film dosimetry for radiation processing

    International Nuclear Information System (INIS)

    Humphreys, J.C.; McLaughlin, W.L.

    1981-01-01

    Commercially available plastic films containing dyes or dye precursors are convenient dosimeters and imaging media for electron beams or photons used for industrial radiation processing. As ''grainless'' imaging systems having thicknesses down to a few micrometers, they provide high spatial resolution for determining detailed absorbed dose distributions through microdensitometric analysis. The radiation absorption properties of these systems are adjusted by changing film composition so that the dosimeter materials can be made to simulate the material of interest undergoing irradiation. Other advantages include long-term stability, dose-rate independence, and ease of use and calibration. Radiochromic dye films with thicknesses varying from 0.005 to 1 mm are presently used to monitor electron-beam or gamma-ray doses from 10 to 10 5 Gy (10 3 to 10 7 rad), typical of those encountered in medical applications, radiation curing of polymeric composites, wire and cable insulation, shrinkable plastic tubing and film, as well as sterilization of medical supplies and treatment of municipal and industrial wastes. An NBS calibration service to industry involves the traceability of standard 60 Co gamma ray absorbed dose measurements by means of these films employed as transfer standards

  19. Single-shot beam-position monitor for x-ray free electron laser

    Science.gov (United States)

    Tono, Kensuke; Kudo, Togo; Yabashi, Makina; Tachibana, Takeshi; Feng, Yiping; Fritz, David; Hastings, Jerome; Ishikawa, Tetsuya

    2011-02-01

    We have developed an x-ray beam-position monitor for detecting the radiation properties of an x-ray free electron laser (FEL). It is composed of four PIN photodiodes that detect backscattered x-rays from a semitransparent diamond film placed in the beam path. The signal intensities from the photodiodes are used to compute the beam intensity and position. A proof-of-principle experiment at a synchrotron light source revealed that the error in the beam position is reduced to below 7 μm by using a nanocrystal diamond film prepared by plasma-enhanced chemical vapor deposition. Owing to high dose tolerance and transparency of the diamond film, the monitor is suitable for routine diagnostics of extremely intense x-ray pulses from the FEL.

  20. Optical monitoring of gases with cholesteric liquid crystals.

    Science.gov (United States)

    Han, Yang; Pacheco, Katherine; Bastiaansen, Cees W M; Broer, Dirk J; Sijbesma, Rint P

    2010-03-10

    A new approach to optical monitors for gases is introduced using cholesteric liquid crystals doped with reactive chiral compounds. The approach is based on cholesteric pitch length changes caused by a change in helical twisting power (HTP) of the chiral dopants upon reaction with the analyte. The concept is demonstrated for monitoring carbon dioxide via reversible carbamate formation and for oxygen using the irreversible oxidation of a chiral dithiol to a disulfide. Monitoring of CO(2) was achieved by doping a commercial cholesteric liquid crystalline mixture (E7) with 1.6% mol of the 1:1 complex of an optically pure diamine with a TADDOL derivative. Upon exposure to carbon dioxide, the reflection band of a thin film of the mixture shifted from 637 to 495 nm as a consequence of dissociation of the complex after carbamate formation of the diamine. An O(2) monitor was obtained by doping E7 with a chiral binaphthyl dithiol derivative and a nonresponsive codopant. The reflection band of the oxygen monitor film changed from 542 to 600 nm, due to the conformational change accompanying oxidation of the dithiol to disulfide. These monitoring mechanisms hold promise for application in smart packaging, where carbon dioxide and oxygen are of special interest because of their roles in food preservation.

  1. Numerical investigation of unsteady mixing mechanism in plate film cooling

    Directory of Open Access Journals (Sweden)

    Shuai Li

    2016-09-01

    Full Text Available A large-scale large eddy simulation in high performance personal computer clusters is carried out to present unsteady mixing mechanism of film cooling and the development of films. Simulation cases include a single-hole plate with the inclined angle of 30° and blowing ratio of 0.5, and a single-row plate with hole-spacing of 1.5D and 2D (diameters of the hole. According to the massive simulation results, some new unsteady phenomena of gas films are found. The vortex system is changed in different position with the development of film cooling with the time marching the process of a single-row plate film cooling. Due to the mutual interference effects including mutual exclusion, a certain periodic sloshing and mutual fusion, and the structures of a variety of vortices change between parallel gas films. Macroscopic flow structures and heat transfer behaviors are obtained based on 20 million grids and Reynolds number of 28600.

  2. In Situ Hall Effect Monitoring of Vacuum Annealing of In2O3:H Thin Films

    Directory of Open Access Journals (Sweden)

    Hans F. Wardenga

    2015-02-01

    Full Text Available Hydrogen doped In2O3 thin films were prepared by room temperature sputter deposition with the addition of H2O to the sputter gas. By subsequent vacuum annealing, the films obtain high mobility up to 90 cm2/Vs. The films were analyzed in situ by X-ray photoelectron spectroscopy (XPS and ex situ by X-ray diffraction (XRD, optical transmission and Hall effect measurements. Furthermore, we present results from in situ Hall effect measurements during vacuum annealing of In2O3:H films, revealing distinct dependence of carrier concentration and mobility with time at different annealing temperatures. We suggest hydrogen passivation of grain boundaries as the main reason for the high mobility obtained with In2O3:H films.

  3. Investigation of self-indicating radiation personal dosimeter

    International Nuclear Information System (INIS)

    Xia Wen; Ye Honsheng; Lin Min; Xu Lijun; Chen Kesheng; Chen Yizhen

    2014-01-01

    A self-indicating radiation personal dosimeter was investigated using radiation sensitive material diacetylene monomer PCDA, which was a component of the polymerization system. The substrate material, solvent, sensitive material, solution temperature, thickness of film and the preparation method were studied. The dosimeter colour changes from white to blue when exposed 0.1-2.5 Gy, and the linearly dependent coefficient of the exposure response is 0.9998, the stability of absorbency in two weeks after exposure is testified well. It can be used as self-indicating radiation alert personal dosimeter. (authors)

  4. Mindreading Dysfunction in Avoidant Personality Disorder Compared With Other Personality Disorders.

    Science.gov (United States)

    Moroni, Fabio; Procacci, Michele; Pellecchia, Giovanni; Semerari, Antonio; Nicolò, Giuseppe; Carcione, Antonino; Pedone, Roberto; Colle, Livia

    2016-10-01

    The ability to reflect on one's own states of mind and those of others (metacognition or mindreading) is strongly implicated in personality disorders (PDs). Metacognition involves different abilities, and there is evidence that specific abilities can be selectively impaired in different PDs. The purposes of this study were to compare metacognitive competence in avoidant PD (AvPD) with that in other PDs and to investigate whether there is a specific profile for AvPD. Sixty-three patients with AvPD and 224 patients with other PDs were assessed using the Metacognitive Assessment Interview. AvPD patients showed difficulties with two metacognitive functions: monitoring and decentration, even when the severity of psychopathology was controlled for. These results support the hypothesis of specific profiles of metacognitive dysfunction in different PDs and highlight a close link between impaired monitoring and decentration functions and the inhibited and withdrawn personality style typical of AvPD.

  5. Cellulose acetobutyrate films and beryllium oxide discs for low-level radiation monitoring

    International Nuclear Information System (INIS)

    Ventura, S.A.; Kleinschmidt, D.E.; Mbu, J.B.

    1976-01-01

    The effect of mylar films on the attenuation of alpha particle energy and the production of etchable tracks in cellulose acetobutyrate was studied. A model developed predicts a 15-μ optimum mylar film thickness, while experimental results indicated a 22.8-μ optimum. The effect of alpha particle and potassium hydroxide solution interaction with CAB was reviewed and process improvements suggested. The TSEE response of BeO discs to tritium at 5.0 mCi/m 3 for up to 15-hr exposure was also investigated. An average TSEE/β ratio of 0.02 was obtained

  6. A membrane film sensor with encapsulated fluorescent dyes towards express freshness monitoring of packaged food.

    Science.gov (United States)

    Kiryukhin, Maxim V; Lau, Hooi Hong; Goh, Seok Hong; Teh, Cathleen; Korzh, Vladimir; Sadovoy, Anton

    2018-05-15

    A new Membrane Film Sensor (MFS) has been developed to measure pH of fluids. MFS comprises a polyelectrolyte multilayer film with uniformly distributed compartments (microchambers) where a fluorescent sensing dye is encapsulated. Fabricated film is sealed onto a polyethylene film for a future use. MFS was applied to report changes in golden pomfret fillet upon its storage at 5 °C. MFS pH readings were correlated to bacteriological analysis of fish samples. A hike in pH of fish juices happens after 10 days of storage signaling bacterial spoilage of fish. The design of developed MFS allows easy integration with transparent packaging materials for future development of "SMART" packaging sensing food freshness. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Film dosimetry for IMRT: sensitivity corrections

    International Nuclear Information System (INIS)

    Suchowerska, N.; Hoban, P.; Davison, A.; Metcalfe, P.

    2000-01-01

    Full text: The trend towards conformal, dynamic and intensity modulated radiotherapy treatments has furthered the need for true integrating dosimetry. In traditional radiotherapy, film dosimetry is commonly used. The accuracy and reproducibility of film optical density as an indicator of dose, has been associated with several variables. These include the effects of film specific sensitivity, direction of exposure, chemical processing and film scanner sensitivity. In this study, a procedure is developed to account for these variables, with a particular view to film being used as a dosimeter for conformal treatments. An effective sensitometric curve was established by exposing part of a single sheet of film to known doses. All films were processed together and scanned using a DuoscanT1200 transmission scanner, resulting in 12 bit image files. The images were analysed using Osiris software and the results fitted to the modified Williamson equation: P P s (l - 10 αD ) This yields values of α [film sensitivity], and P s [saturation pixel value], allowing individual dosimetry films to be normalised to this sensitometric calibration curve. For validation, a piece of Kodak X Omat-V film was sealed in a head phantom and exposed to a total of 51 IMRT fields, delivered from 6 gantry angles. The rest of the sheet of film was resealed and exposed to four known doses, providing sensitometric data, specific to this exposure. All films were then processed, scanned and analysed as described above. Observed variations in serial films exposed to 50cGy is in the order of 9% [mean 25.0,standard deviation = 3.2]. The automatic gain of the scanner system typically contributed 4% variation and needs to be carefully monitored. Results indicate that by using the sensitometric data from each exposure, the collective errors can be minimised. The IMRT exposure results confirm that the above process is viable for use in dosimetry for conformal radiation therapy. Copyright (2000) Australasian

  8. Effect of Antioxidants on Radiation Vulcanization Natural Rubber Latex (RVNRL) Film

    International Nuclear Information System (INIS)

    Syuhada Ramli; Sofian Ibrahim; Muhammad Saiful Omar

    2015-01-01

    This paper presents the results on the effects of different antioxidants used in Radiation Vulcanization Natural Rubber Latex (RVNRL)) films between 0 to 10 weeks monitoring. Antioxidants used for the RVNRL formulation were Aquanox LP, Irganox and Wingstay L. Color difference evaluation by using Chroma Meter CR-400 found that RVNRL film with Irganox was the most stained yellowish after 8 weeks monitoring. Tensile strength for RVNRL with Aquanox found achieved the optimum strength between 25.4 to 27.13 mPa. The scanner electron microscopic (SEM) indicated more Aquanox molecules to penetrate and interact with the rubber molecule, thus becoming more effective inhibitor against its oxidative ageing. (author)

  9. Polymer Thick-Film Sensors: Possibilities for Smartcard Biometrics

    NARCIS (Netherlands)

    Henderson, N.J.; Papakostas, T.V.; White, N.M.; Hartel, Pieter H.

    In this paper the potential of polymer thick-film sensors are assessed for use as biometric sensors on smartcards. Piezoelectric and piezoresistive sensors have been printed on flexible polyester, then bonded to smartcard blanks. The tactile interaction of a person with these sensors has been

  10. Hybrid methyl green/cobalt-polyoxotungstate nanostructured films: Self-assembly, electrochemical and electrocatalytic properties

    Energy Technology Data Exchange (ETDEWEB)

    Novais, Hugo C.; Fernandes, Diana M., E-mail: diana.fernandes@fc.up.pt; Freire, Cristina, E-mail: acfreire@fc.up.pt

    2015-08-30

    Graphical abstract: Hybrid {MG/Co(PW9)2}{sub n} multilayer films were successfully prepared and exhibit W-based electrocatalytic activity towards reduction of nitrite and iodate anions. - Highlights: • Layer-by-layer hybrid films {MG/Co(PW_9)_2}{sub n} were sucessfully prepared. • UV–vis was used to monitor film build-up and showed regular stepwise film growth. • XPS confirmed sucessfull {MG/Co(PW_9)_2}{sub n} film fabrication. • Films showed excellent electrocatalytic activity towards nitrite and iodate reduction. - Abstract: Hybrid multilayer films were prepared by alternately depositing cationic dye methyl green (MG) and anionic sandwich-type polyoxometalate K{sub 10}[Co{sub 4}(H{sub 2}O){sub 2}(PW{sub 9}O{sub 34}){sub 2}] (Co(PW{sub 9}){sub 2}) via electrostatic layer-by-layer (LbL) self-assembly method. Film build-up was monitored by UV–vis spectroscopy which showed a regular stepwise growth. X-ray photoelectron spectroscopy data confirmed the successful fabrication of the hybrid films with MG-Co(PW{sub 9}){sub 2} composition and scanning electron microscopy images revealed a completely covered surface with a non-uniform distribution of the molecular species. Electrochemical characterization of films by cyclic voltammetry revealed two tungsten-based reduction processes in the potential range between −0.9 and −0.5 V due to W{sup VI} → W{sup V} in Co(PW{sub 9}){sub 2}. Studies with the redox probes, [Fe(CN){sub 6}]{sup 3−/4−} and [Ru(NH{sub 3}){sub 6}]{sup 3+/2+}, revealed that not only the electrostatic attractions or repulsions have effects on the kinetics of the probe reactions, but also the film thickness. Additionally, the {MG/Co(PW_9)_2}{sub n} multilayer films exhibit efficient W-based electrocatalytic activity towards reduction of nitrite and iodate.

  11. Performance testing of UK personal dosimetry laboratories

    CERN Document Server

    Marshall, T O

    1985-01-01

    The proposed Ionising Radiations Regulations will require all UK personal dosimetry laboratories that monitor classified personnel to be approved for personal dosimetry by the Health and Safety Executive. It is suggested that these approvals should be based on general and supplementary criteria published by the British Calibration Service (BCS) for laboratory approval for the provision of personal dosimetry services. These criteria specify certain qualitative requirements and also indicate the need for regular tests of performance to be carried out to ensure constancy of dosimetric standards. This report concerns the latter. The status of the BCS criteria is discussed and the need for additional documents to cover new techniques and some modifications to existing documents is indicated. A means is described by which the technical performance of laboratories, concerned with personal monitoring for external radiations, can be assessed, both initially and ongoing. The costs to establish the scheme and operate it...

  12. Hand and foot contamination monitor

    International Nuclear Information System (INIS)

    Jakati, R.K.; Kaptral, R.S.; Ananthkrishnan, T.S.; Pansare, M.G.

    1989-01-01

    In order to make quick measurements of beta and gamma contaminations on hands and feet of personnel working in radioactive environments, hand and foot contamination monitors are widely used. This paper describes such a monitor system designed with Intel 8085 based microcomputer. The monitoring and warning system is designed to perform measurement of activity spread over surface of hands and soles of shoes or feet. Even though the system has many features to aid testing and maintainance operation, it is easy to use for unskilled persons. In order to check the contamination, the person stands on platform and inserts both his hands into detector assemblies thereby actuating the sensing switches. After a preset interval, annunciation of clean or contaminated status is declared by the system. (author)

  13. Evaluation of residual stress in sputtered tantalum thin-film

    Energy Technology Data Exchange (ETDEWEB)

    Al-masha’al, Asa’ad, E-mail: asaad.al@ed.ac.uk; Bunting, Andrew; Cheung, Rebecca

    2016-05-15

    Highlights: • Tantalum thin-films have been deposited by DC magnetron sputtering system. • Thin-film stress is observed to be strongly influenced by sputtering pressure. • Transition towards the compressive stress is ascribed to the annealing at 300 °C. • Expose thin-film to air ambient or ion bombardment lead to a noticeable change in the residual stress. - Abstract: The influence of deposition conditions on the residual stress of sputtered tantalum thin-film has been evaluated in the present study. Films have been deposited by DC magnetron sputtering and curvature measurement method has been employed to calculate the residual stress of the films. Transitions of tantalum film stress from compressive to tensile state have been observed as the sputtering pressure increases. Also, the effect of annealing process at temperature range of 90–300 °C in oxygen ambient on the residual stress of the films has been studied. The results demonstrate that the residual stress of the films that have been deposited at lower sputtering pressure has become more compressive when annealed at 300 °C. Furthermore, the impact of exposure to atmospheric ambient on the tantalum film stress has been investigated by monitoring the variation of the residual stress of both annealed and unannealed films over time. The as-deposited films have been exposed to pure Argon energy bombardment and as result, a high compressive stress has been developed in the films.

  14. Propagation of bulk longitudinal waves in thin films using laser ultrasonics

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yun Young [Dept. of Mechanical Engineering, Dong-eui University, Busan (Korea, Republic of)

    2016-08-15

    This paper presents the investigation of the propagation behavior of bulk longitudinal waves generated by an ultrafast laser system in thin films. A train of femtosecond laser pulses was focused onto the surface of a 150-nm thick metallic (chromium or aluminum) film on a silicon substrate to excite elastic waves, and the change in thermoreflectance at the spot was monitored to detect the arrival of echoes from the film/substrate interface. The experimental results show that the film material characteristics such as the wave velocity and Young's modulus can be evaluated through curve-fitting in numerical solutions. The material properties of nanoscale thin films are difficult to measure using conventional techniques. Therefore, this research provides an effective method for the nondestructive characterization of nanomaterials.

  15. Personal dosimetry at the radiation accidents

    International Nuclear Information System (INIS)

    Perevoznikov, O.N.; Klyuchnikov, A.A.; Kanchenko, V.A.

    2007-01-01

    The radiation accidents of different types and the methods of the dosimetry used at the consequences liquidation are considered. The long-term experience of the population personal instrumental dosimetric control carrying out at the ChNPP accident consequences liquidation is widely covered in details. The concepts are stated out and the results are presented on the functioning of the created system for personal dose monitoring of the population of Ukraine irradiation. The use of the person radiation counters at the internal irradiation population and personal dose assessment is considered in details

  16. Does cultural exposure partially explain the association between personality and political orientation?

    Science.gov (United States)

    Xu, Xiaowen; Mar, Raymond A; Peterson, Jordan B

    2013-11-01

    Differences in political orientation are partly rooted in personality, with liberalism predicted by Openness to Experience and conservatism by Conscientiousness. Since Openness is positively associated with intellectual and creative activities, these may help shape political orientation. We examined whether exposure to cultural activities and historical knowledge mediates the relationship between personality and political orientation. Specifically, we examined the mediational role of print exposure (Study 1), film exposure (Study 2), and knowledge of American history (Study 3). Studies 1 and 2 found that print and film exposure mediated the relationships Openness to Experience and Conscientiousness have with political orientation. In Study 3, knowledge of American history mediated the relationship between Openness and political orientation, but not the association between Conscientiousness and political orientation. Exposure to culture, and a corollary of this exposure in the form of acquiring knowledge, can therefore partially explain the associations between personality and political orientation.

  17. A wideband optical monitor for a planetary-rotation coating-system

    International Nuclear Information System (INIS)

    Campanelli, M.B.; Smith, D.J.

    1998-01-01

    A substrate-specific, through-planet, wideband optical coating monitor is being developed to increase production yield and the understanding of physical vapor deposition (PVD) coatings fabricated in the Optical Manufacturing Laboratory at the University of Rochester's Laboratory for Laser Energetics. In-situ wideband optical monitoring of planetary rotation systems allows direct monitoring of large, expensive substrates with complex layering schemes. The optical monitor discussed here is under development for coating several large (e.g., 80.7 x 41.7 x 9.0 cm) polarizers for the National Ignition Facility. Wideband optical monitoring of the production substrates is used in concert with an array of crystal monitors for process control, film parameter evaluation, and error detection with associated design reoptimization. The geometry of a planetary rotation system, which produces good uniformity across large substrates, makes optical monitoring more difficult. Triggering and timing techniques for data acquisition become key to the process because the optical coating is available only intermittently for monitoring. Failure to properly consider the effects of the system dynamics during data retrieval and processing may result in significant decreases in the spectral data's reliability. Improved data accuracy allows better determination of film thicknesses, indices, and inhomogeneities and enables in-situ error detection for design reoptimization

  18. Real-time corrosion monitoring of steel influenced by microbial activity (SRB) under controlled seawater injection conditions

    Energy Technology Data Exchange (ETDEWEB)

    Kane, Russell D. [InterCorr International, Inc., 14503 Bammel N. Houston Road, Suite 300, Houston, TX 77019 (United States); Campbell, Scott [Commercial Microbiology Inc., 10400 Westoffice Drive Suite 107, Houston, TX 77042 (United States)

    2004-07-01

    An experimental study of microbiologically influenced corrosion (MIC) was conducted involving online, real-time monitoring of a bio-film loop under controlled conditions simulating oil field water handling and injection. Bio-film growth, MIC and biocide efficacy were monitored using an automated, multi-technique monitoring system including linear polarization resistance, electrochemical noise and harmonic distortion analysis. This data was correlated with conventional off-line methods to differentiate conditions of varying MIC activity in real-time to facilitate quick assessment and operator intervention. (authors)

  19. Receiver operating characteristic analysis of chest radiographs with computed radiography and conventional analog films

    International Nuclear Information System (INIS)

    Morioka, C.; Brown, K.; Dalter, S.; Milos, M.J.; Huang, H.K.; Kangarloo, H.; Boechat, I.M.; Batra, P.

    1988-01-01

    Receiver operating characteristic is used to compare the image quality of films obtained digitally using computed radiography (CR) and conventionally using analog film following fluoroscopic examination. Twenty-four cases, some with a solitary noncalcified nodule and/or pneumothorax, were collected. Ten radiologists have been tested viewing analog and CR digital films separately. Preliminary results indicate that there is no significant difference in the ability to detect either a pneumothorax or a solitary noncalcified nodule when comparing CR digital film with conventional analog film. A comparison of the CR digital image displayed on a 2,048-line monitor against analog and CR digital film is in progress

  20. “What Can Hume Teach Us about Film Evaluation?”

    Directory of Open Access Journals (Sweden)

    Robert R. Clewis

    2014-11-01

    Full Text Available This article identifies three distinct temporal notions in Hume’s aesthetics: passing the test of time, repeated viewing of a work, and the personal aging of the critic. It applies these ideas to the evaluation and enjoyment of films. It characterizes positive, negative, and ambivalent film aging, which are associated with nostalgia, boredom, and comic amusement, respectively, and which bear on our enjoyment, not evaluation, of film. The paper discusses Allen’s Zelig, Antonioni’s La Notte, Cameron’s The Terminator, Lucas’s Star Wars, Scorsese’s Taxi Driver, Spielberg’s E.T.: The Extra-Terrestrial, and Renoir’s La Règle du Jeu. 

  1. Radiation contamination monitors

    International Nuclear Information System (INIS)

    Kato, Tsutomu; Iba, Hiroshi; Sato, Hiroshi

    1999-01-01

    To make sure of no contamination on people, used articles and working uniforms coming out of the radiation controlled area, nuclear power plants are equipped with radioactive contamination monitors. This paper outlines the basic specifications and advantages of our personnel surface contamination monitors to inspect whole-body surface contamination of people coming out, article surface contamination monitors to inspect the surface and inside contamination of used articles brought out, laundry monitors to inspect surface contamination of working uniforms used in the area before and after a wash, and whole-body counters to inspect and measure the internal contamination of a person out of the area. (author)

  2. Chemically abrupt interface between Ce oxide and Fe films

    International Nuclear Information System (INIS)

    Lee, H.G.; Lee, D.; Kim, S.; Kim, S.G.; Hwang, Chanyong

    2005-01-01

    A chemically abrupt Fe/Ce oxide interface can be formed by initial oxidation of an Fe film followed by deposition of Ce metal. Once a Ce oxide layer is formed on top of Fe, it acts a passivation barrier for oxygen diffusion. Further deposition of Ce metal followed by its oxidation preserve the abrupt interface between Ce oxide and Fe films. The Fe and Ce oxidation states have been monitored at each stage using X-ray photoelectron spectroscopy

  3. Personal radon daughter dosimetry

    International Nuclear Information System (INIS)

    Stocker, H.

    1979-12-01

    The conventional means of radon daughter exposure estimatikn for uranium miners in Canada is by grab sampling and time weighting. Personal dosimetry is a possible alternative method with its own advantages and limitations. The author poses basic questions with regard to two methods of radon daughter detection, thermoluminescent chips and track-etch film. An historical review of previous and current research and development programs in Canada and in other countries is presented, as are brief results and conclusions of each dosimeter evaluation

  4. An international cooperation by using an all-encompassing passive radon monitor

    International Nuclear Information System (INIS)

    Tommasino, L.; Chen, J.; Falcomer, R.; Janik, M.; Kanda, R.; DeFelice, F.; Cardellini, F.; Trevisi, R.; Leonardi, F.; Magnoni, M.; Chiaberto, E.; Agnesod, G.; Ragani, M. Faure; Espinosa, G.; Golzarri, J.; Kozak, K.; Mazur, J.

    2017-01-01

    The recently developed radon film-badge makes it possible to measure radon indoors, in soil, in water and/or in aqueous media (e.g. mud). As a result of its wide response linearity, this monitor has been successfully used to measure radon in-water with concentrations from 10 to ∼10 000 Bq/L. By exploiting the unique characteristics of this badge, a mini-survey has been carried out by Health Canada in which radon in water was measured from 12 private wells, as well as in tap water originating from the Ottawa River. Due to the widespread interest of different laboratories in using these passive monitors, laboratories were provided with plastic films to construct their own badges by using in-house CR-39 detectors. Monitors were then irradiated by a known radon concentration at the National Institute of Radiation Metrology (ENEA) s radon chamber and sent back to each laboratory for processing and counting. Even though these laboratories have been using different etching- and counting procedures, the film-badge responses varied only within ∼12%. (authors)

  5. Experiences in the monitoring of radiation workers in industry and hospitals in the Philippines

    International Nuclear Information System (INIS)

    Mateo, A.J.

    1976-08-01

    The task of monitoring of radiation doses among radiation workers employed either in industry and hospitals in the Philippines is presently being undertaken by the Philippine Atomic Energy Commission. These radiation monitoring devices cover not only radioactive materials or sources but also x-ray machines. The most common dosimetry used is the film badge. This paper presents some of the experiences gained in the use of the film badge and other dosimeters

  6. Inspiring peer-to-peer educations with film

    Science.gov (United States)

    Vachon, R. W.

    2014-12-01

    Oceans are vast, complicated, often inaccessible, three-dimensional and dark (for the most part). The value, vulnerabilities and dynamics of marine systems are quite far removed from the consciousness of many people. However, these reasons are not alibis for not understanding and appreciating oceans deep-rooted influences on our lives. Currently, the Nereus Program, a fellowship of climate, fisheries and computer modeling scientists, are accessing school systems in person and virtually, motivating teens to tell stories about their local understanding of the ocean's influence on their communities (even if they live in a landlocked location). In it's first iteration, we are soliciting youth to communicate through the popular medium of film. These films will be assembled into an on-line digital field guide. In part, this program is designed to be a peer-to-peer educational technique, where civilians are teaching other civilians about local or regional ocean dynamics. Additionally, the act of teaching through film is a proven method for deepening engagement, learning and empowerment of the individuals producing the films.

  7. Perspectives on wellness self-monitoring tools for older adults.

    Science.gov (United States)

    Huh, Jina; Le, Thai; Reeder, Blaine; Thompson, Hilaire J; Demiris, George

    2013-11-01

    Our purpose was to understand different stakeholder perceptions about the use of self-monitoring tools, specifically in the area of older adults' personal wellness. In conjunction with the advent of personal health records, tracking personal health using self-monitoring technologies shows promising patient support opportunities. While clinicians' tools for monitoring of older adults have been explored, we know little about how older adults may self-monitor their wellness and health and how their health care providers would perceive such use. We conducted three focus groups with health care providers (n=10) and four focus groups with community-dwelling older adults (n=31). Older adult participants' found the concept of self-monitoring unfamiliar and this influenced a narrowed interest in the use of wellness self-monitoring tools. On the other hand, health care provider participants showed open attitudes toward wellness monitoring tools for older adults and brainstormed about various stakeholders' use cases. The two participant groups showed diverging perceptions in terms of: perceived uses, stakeholder interests, information ownership and control, and sharing of wellness monitoring tools. Our paper provides implications and solutions for how older adults' wellness self-monitoring tools can enhance patient-health care provider interaction, patient education, and improvement in overall wellness. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  8. Perspectives on Wellness Self-Monitoring Tools for Older Adults

    Science.gov (United States)

    Huh, Jina; Le, Thai; Reeder, Blaine; Thompson, Hilaire J.; Demiris, George

    2013-01-01

    Purpose Our purpose was to understand different stakeholder perceptions about the use of self-monitoring tools, specifically in the area of older adults’ personal wellness. In conjunction with the advent of personal health records, tracking personal health using self-monitoring technologies shows promising patient support opportunities. While clinicians’ tools for monitoring of older adults have been explored, we know little about how older adults may self-monitor their wellness and health and how their health care providers would perceive such use. Methods We conducted three focus groups with health care providers (n=10) and four focus groups with community-dwelling older adults (n=31). Results Older adult participants’ found the concept of self-monitoring unfamiliar and this influenced a narrowed interest in the use of wellness self-monitoring tools. On the other hand, health care provider participants showed open attitudes towards wellness monitoring tools for older adults and brainstormed about various stakeholders’ use cases. The two participant groups showed diverging perceptions in terms of: perceived uses, stakeholder interests, information ownership and control, and sharing of wellness monitoring tools. Conclusions Our paper provides implications and solutions for how older adults’ wellness self-monitoring tools can enhance patient-health care provider interaction, patient education, and improvement in overall wellness. PMID:24041452

  9. Monitoring of diisopropyl fluorophosphate hydrolysis by fluoride-selective polymeric films using absorbance spectroscopy

    International Nuclear Information System (INIS)

    Ramanathan, Madhumati; Wang Lin; Wild, James R.; Meyeroff, Mark E.; Simonian, Aleksandr L.

    2010-01-01

    In this study, a novel system for the detection and quantification of organofluorophosphonates (OFP) has been developed by using an optical sensing polymeric membrane to detect the fluoride ions produced upon OFP hydrolysis. Diisopropyl fluorophosphate (DFP), a structural analogue of type G chemical warfare agents such as Sarin (GB) and Soman (GD), is used as the surrogate target analyte. An optical sensing fluoride ion selective polymeric film was formulated from plasticized PVC containing aluminum(III) octaethyl porphyrin and ETH 7075 chromoionophore (Al[OEP]-ETH 7075). Selected formulations were used to detect the fluoride ions produced by the catalytic hydrolysis of DFP by the enzyme organophosphate hydrolase (OPH, EC 3.1.8.1). The changes in absorbance that corresponded to the deprotonated state of chromoionophore within the film results from simultaneous coextraction of fluoride and protons as DFP hydrolysis takes place in the solution phase in contact with the film. The developed sensing system demonstrates excellent sensitivity for concentrations as low as 0.1 μM DFP.

  10. Monitoring of diisopropyl fluorophosphate hydrolysis by fluoride-selective polymeric films using absorbance spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ramanathan, Madhumati [Materials Research and Education Center, Auburn University, Auburn, AL 36849 (United States); Wang Lin [Department of Chemistry, University of Michigan, 930 North University, Ann Arbor, MI 48109 (United States); Wild, James R. [Biochemistry and Biophysics Department, Texas A and M University Texas AgriLife Research Program, College Station, TX 77843-2128 (United States); Meyeroff, Mark E. [Department of Chemistry, University of Michigan, 930 North University, Ann Arbor, MI 48109 (United States); Simonian, Aleksandr L., E-mail: simonal@auburn.edu [Materials Research and Education Center, Auburn University, Auburn, AL 36849 (United States)

    2010-05-14

    In this study, a novel system for the detection and quantification of organofluorophosphonates (OFP) has been developed by using an optical sensing polymeric membrane to detect the fluoride ions produced upon OFP hydrolysis. Diisopropyl fluorophosphate (DFP), a structural analogue of type G chemical warfare agents such as Sarin (GB) and Soman (GD), is used as the surrogate target analyte. An optical sensing fluoride ion selective polymeric film was formulated from plasticized PVC containing aluminum(III) octaethyl porphyrin and ETH 7075 chromoionophore (Al[OEP]-ETH 7075). Selected formulations were used to detect the fluoride ions produced by the catalytic hydrolysis of DFP by the enzyme organophosphate hydrolase (OPH, EC 3.1.8.1). The changes in absorbance that corresponded to the deprotonated state of chromoionophore within the film results from simultaneous coextraction of fluoride and protons as DFP hydrolysis takes place in the solution phase in contact with the film. The developed sensing system demonstrates excellent sensitivity for concentrations as low as 0.1 {mu}M DFP.

  11. Environmental monitoring report: Sandia Laboratories, 1976

    International Nuclear Information System (INIS)

    Simmons, T.N.

    1977-04-01

    Water and vegetation are monitored to determine Sandia Laboratories impact on the surrounding environment. Nonradioactive pollutants released are reported. Radioactive effluents are also reported and their person-rem contribution to the Albuquerque population is calculated. The environmental monitoring for calendar year 1976 shows that concentrations of radioactive materials in the Albuquerque area are typical of natural background for the area. An exception is a single onsite location where slightly abnormal uranium concentrations are expected. An estimated 0.044 person-rem Albuquerque area (80 km radius) population dose commitment results from calculated Sandia Laboratories releases. Over the same area 57,000 person-rem is accumulated from natural background. There were no measurable offsite radioactive effluent releases in CY 1976

  12. Performance testing of UK personal dosimetry laboratories

    International Nuclear Information System (INIS)

    Marshall, T.O.

    1985-01-01

    The proposed Ionising Radiations Regulations will require all UK personal dosimetry laboratories that monitor classified personnel to be approved for personal dosimetry by the Health and Safety Executive. It is suggested that these approvals should be based on general and supplementary criteria published by the British Calibration Service (BCS) for laboratory approval for the provision of personal dosimetry services. These criteria specify certain qualitative requirements and also indicate the need for regular tests of performance to be carried out to ensure constancy of dosimetric standards. This report concerns the latter. The status of the BCS criteria is discussed and the need for additional documents to cover new techniques and some modifications to existing documents is indicated. A means is described by which the technical performance of laboratories, concerned with personal monitoring for external radiations, can be assessed, both initially and ongoing. The costs to establish the scheme and operate it are also estimated. (author)

  13. Novel Monitoring Techniques for Characterizing Frictional Interfaces in the Laboratory

    Directory of Open Access Journals (Sweden)

    Paul A. Selvadurai

    2015-04-01

    Full Text Available A pressure-sensitive film was used to characterize the asperity contacts along a polymethyl methacrylate (PMMA interface in the laboratory. The film has structural health monitoring (SHM applications for flanges and other precision fittings and train rail condition monitoring. To calibrate the film, simple spherical indentation tests were performed and validated against a finite element model (FEM to compare normal stress profiles. Experimental measurements of the normal stress profiles were within −7.7% to 6.6% of the numerical calculations between 12 and 50 MPa asperity normal stress. The film also possessed the capability of quantifying surface roughness, an important parameter when examining wear and attrition in SHM applications. A high definition video camera supplied data for photometric analysis (i.e., the measure of visible light of asperities along the PMMA-PMMA interface in a direct shear configuration, taking advantage of the transparent nature of the sample material. Normal stress over individual asperities, calculated with the pressure-sensitive film, was compared to the light intensity transmitted through the interface. We found that the luminous intensity transmitted through individual asperities linearly increased 0.05643 ± 0.0012 candelas for an increase of 1 MPa in normal stress between normal stresses ranging from 23 to 33 MPa.

  14. GREENHOUSE PLASTIC FILMS CAPABLE OF MODIFYING THE SPECTRAL DISTRIBUTION OF SOLAR RADIATION

    Directory of Open Access Journals (Sweden)

    Evelia Schettini

    2010-03-01

    Full Text Available The aim of this paper was to investigate the radiometric properties of innovative covering films for protected cultivation capable of modifying the spectral distribution of the transmitted radiation and thus the vegetative activity. Two photoselective films, three photoluminescent films and one low-density polyethylene film were used as greenhouse coverings for cherry trees and peach trees, grown in pots. The photoselective films were characterised by a reduction of the R/FR ratio in comparison to the natural solar radiation. Tree growth parameters, such as the apical shoot of cherry trees and the shoot of peach trees, were monitored. Different responses to vegetative activities were observed under the films, depending on the species, with a higher shoots growth rate in the peach with respect to the cherry. The photoselective film characterised by the lowest R/FR ratio significantly enhanced the growth of cherry and peach trees in comparison to the trees cultivated under the other greenhouse films

  15. Monitoring of composite structures using a network of integrated PVDF film transducers

    International Nuclear Information System (INIS)

    Guzmán, Enrique; Cugnoni, Joël; Gmür, Thomas

    2015-01-01

    Aiming to reduce costs, polyvinylidene difluoride (PVDF) film patches are an emerging alternative to more classic piezoelectric technologies, like ceramic patches, as transducers to measure local deformation in many structural applications. This choice is supported by advantages such as the low weight and mechanical flexibility of PVDF, making this polymer suitable for embedding inside full scale polymer based composite structures. Piezoelectric transducer patches can be used as actuators to dynamically excite full-scale composite structures, and as sensors to measure the strain. The main objective of this paper is to verify that the PVDF transducers can provide exploitable signals in the context of structural health monitoring. In order to do so, two aspects of the design of transducer network are investigated: the optimization of the sensor network, for which the effective independence method is proposed, and the use of operational modal analysis (OMA), since it is a simple method to extract the natural frequencies of a structure from a time series. The results of the analysis are compared to a reference set issued from experimental modal analysis (EMA), a simple, well-known, classic method, which is carried out using accelerometers and an impact hammer. By statistical means, it is shown that there is no significant difference between the two methods, and an optimized PVDF transducer network combined with OMA can perform the dynamic analysis of a structure as well as a classic EMA setup would do. This leads the way to the use of low-cost PVDF embedded transducer networks for robust composite material characterization. (paper)

  16. Exploring the value of qualitative research films in clinical education.

    Science.gov (United States)

    Toye, Fran; Jenkins, Sue; Seers, Kate; Barker, Karen

    2015-11-27

    Many healthcare professionals use both quantitative and qualitative research to inform their practice. The usual way to access research findings is through peer-reviewed publications. This study aimed to understand the impact on healthcare professionals of watching and discussing a short research based film. The film, 'Struggling to be me' portrays findings from a qualitative synthesis exploring people's experiences of chronic pain, and was delivered as part of an inter-professional postgraduate e-learning module. The innovation of our study is to be the first to explore the impact of qualitative research portrayed through the medium of film in clinical education. All nineteen healthcare professionals enrolled on the course in December 2013 took part in on-line interviews or focus groups. We recorded and transcribed the interviews verbatim and used the methods of Grounded Theory to analyse the interview transcripts. Watching and discussing the film became a stimulus for learning : (a) A glimpse beneath the surface explored a pro-active way of seeing the person behind the pain (b) Pitfalls of the Medical Model recognised the challenge, for both patient and clinician, of 'sitting with' rather than 'fixing' an ill person; (c) Feeling bombarded by despair acknowledged the intense emotions that the clinicians brings to the clinical encounter; (d) Reconstructing the clinical encounter as a shared journey reconstructed the time-constrained clinical encounter as a single step on a shared journey towards healing, rather than fixing. Films portraying qualitative research findings can stimulate a pro-active and dialectic form of knowing. Research-based qualitative films can make qualitative findings accessible and can be a useful resource in clinical training. Our research presents, for the first time, specific learning themes for clinical education.

  17. The smart house for older persons and persons with physical disabilities: structure, technology arrangements, and perspectives.

    Science.gov (United States)

    Stefanov, Dimitar H; Bien, Zeungnam; Bang, Won-Chul

    2004-06-01

    Smart houses are considered a good alternative for the independent life of older persons and persons with disabilities. Numerous intelligent devices, embedded into the home environment, can provide the resident with both movement assistance and 24-h health monitoring. Modern home-installed systems tend to be not only physically versatile in functionality but also emotionally human-friendly, i.e., they may be able to perform their functions without disturbing the user and without causing him/her any pain, inconvenience, or movement restriction, instead possibly providing him/her with comfort and pleasure. Through an extensive survey, this paper analyzes the building blocks of smart houses, with particular attention paid to the health monitoring subsystem as an important component, by addressing the basic requirements of various sensors implemented from both research and clinical perspectives. The paper will then discuss some important issues of the future development of an intelligent residential space with a human-friendly health monitoring functional system.

  18. Epitaxial growth of fcc Ti films on Al(001) surfaces

    International Nuclear Information System (INIS)

    Saleh, A.A.; Shutthanandan, V.; Shivaparan, N.R.; Smith, R.J.; Tran, T.T.; Chambers, S.A.

    1997-01-01

    High-energy ion scattering (HEIS), x-ray photoelectron spectroscopy, and x-ray photoelectron diffraction (XPD) were used to study the growth of thin Ti films on Al(001) surfaces. The Al surface peak area in the backscattered ion spectrum of MeV He + ions, incident along the [00 bar 1] direction, was used to monitor the atomic structure of the Ti films during growth. An initial decrease in the area was observed indicating epitaxial film growth. This decrease continued up to a critical film thickness of about 5.5 ML, after which point the structure of the film changed. Titanium films 3, 5, and 9 ML thick were characterized using XPD in the same chamber. Both the HEIS and XPD results show that the Ti films grow with an fcc structure on Al(001). A tetragonal distortion of 2.4% in the fcc Ti film was measured using ions incident along the [10 bar 1] direction. Although there is a general similarity of fcc Ti growth on both Al(001) and Al(110), the submonolayer growth regime does show differences for the two surfaces. copyright 1997 The American Physical Society

  19. Wireless monitoring system for personal dose

    International Nuclear Information System (INIS)

    Kobayashi, Hironobu; Kawamura, Takeshi; Inoue, Takayuki

    2000-01-01

    Fuji Electric has developed a system for the higher radiation controlled area in nuclear power plants, in which exposure dose data measured on the wearer's chest, hands, and legs are transferred by wireless to the data control equipment so that the exposure dose can be controlled in real time. The system using a specified low-power radio wave causes no interference to the other types of dosimeters. The data control equipment automatically saves data received from the dosimeters and also has functions of calibration of dosimeters and maintenance of the wireless system. This paper describes the wireless monitoring system that consists of chest and parts dosimeters and data control equipment. (author)

  20. Student health professionals' attitudes and experience after watching "Ida's Diary", a first-person account of living with borderline personality disorder: Mixed methods study.

    Science.gov (United States)

    Dickens, Geoffrey L; Lamont, Emma; Stirling, Fiona J

    2018-06-01

    There is increasing interest in the use of commercial movies in nursing education, or "cinenurducation". There is a need for educational interventions which target mental health nurses' attitudes towards people with borderline personality disorder. To investigate and evaluate the experience and effects of attendance at a screening of the movie Ida's Diary, a first-person account of living with borderline personality disorder. Mixed methods design comprising a within-subjects AB longitudinal survey, and a qualitative analysis of participant-generated data and researcher field notes from a World Café discussion group. One university in Scotland. N = 66 undergraduate and postgraduate mental health nursing and counselling students. Participants completed measures of cognitive and emotional attitudes towards, and knowledge about, people with borderline personality disorder before and after one of two film screenings. We conducted a World Café discussion group after the second screening. Resulting data were subject to a qualitative thematic analysis. Quantitative analysis revealed a five-factor cognitive and a single-factor emotional attitude structure. Cognitive-attitudinal items related to treatment deservingness and value of mixed treatment approaches improved across iterations. Total knowledge score did not change, but one item about borderline personality disorder as a precursor to schizophrenia received considerably more incorrect endorsement post-screening. Qualitative analysis revealed five themes: Facilitation and inhibition of learning; promotion but not satiation of appetite for knowledge; challenging existing understanding; prompting creativity and anxiety; and initiating thinking about the bigger picture. Participants found the film thought provoking; it increased their appetite for knowledge. Findings suggest that screening should be delivered in conjunction with more didactic information about borderline personality disorder. Copyright © 2018

  1. Highly Sensitive and Fast Response Colorimetric Humidity Sensors Based on Graphene Oxides Film.

    Science.gov (United States)

    Chi, Hong; Liu, Yan Jun; Wang, FuKe; He, Chaobin

    2015-09-16

    Uniform graphene oxide (GO) film for optical humidity sensing was fabricated by dip-coating technique. The resulting GO thin film shows linear optical shifts in the visible range with increase of humidity in the whole relative humidity range (from dry state to 98%). Moreover, GO films exhibit ultrafast sensing to moisture within 250 ms because of the unique atomic thinness and superpermeability of GO sheets. The humidity sensing mechanism was investigated using XRD and computer simulation. The ultrasensitive humidity colorimetric properties of GOs film may enable many potential applications such as disposable humidity sensors for packaging, health, and environmental monitoring.

  2. Process Modeling With Inhomogeneous Thin Films

    Science.gov (United States)

    Machorro, R.; Macleod, H. A.; Jacobson, M. R.

    1986-12-01

    Designers of optical multilayer coatings commonly assume that the individual layers will be ideally homogeneous and isotropic. In practice, it is very difficult to control the conditions involved in the complex evaporation process sufficiently to produce such ideal films. Clearly, changes in process parameters, such as evaporation rate, chamber pressure, and substrate temperature, affect the microstructure of the growing film, frequently producing inhomogeneity in structure or composition. In many cases, these effects are interdependent, further complicating the situation. However, this process can be simulated on powerful, interactive, and accessible microcomputers. In this work, we present such a model and apply it to estimate the influence of an inhomogeneous layer on multilayer performance. Presently, the program simulates film growth, thermal expansion and contraction, and thickness monitoring procedures, and includes the effects of uncertainty in these parameters or noise. Although the model is being developed to cover very general cases, we restrict the present discussion to isotropic and nondispersive quarterwave layers to understand the particular effects of inhomogeneity. We studied several coating designs and related results and tolerances to variations in evaporation conditions. The model is composed of several modular subprograms, is written in Fortran, and is executed on an IBM-PC with 640 K of memory. The results can be presented in graphic form on a monochrome monitor. We are currently installing and implementing color capability to improve the clarity of the multidimensional output.

  3. The use of a personal digital assistant for dietary self-monitoring does not improve the validity of self-reports of energy intake.

    Science.gov (United States)

    Yon, Bethany Ann; Johnson, Rachel K; Harvey-Berino, Jean; Gold, Beth Casey

    2006-08-01

    Underreporting of energy intake is a pervasive problem and resistant to improvement, especially among people with overweight and obesity. The goal of this study was to investigate whether the use of a personal digital assistant (PDA) for dietary self-monitoring would reduce underreporting prevalence and improve the validity of self-reported energy intake. Adults with overweight and obesity (n=61, 92% women, mean age 48.2 years, mean body mass index 32.3) were provided with a PalmZire 21 (Palm, Inc, Sunnyvale, CA) loaded with Calorie King's Diet Diary software (version 3.2.2, 2002, Family Health Network, Costa Mesa, CA). Subjects participated in a 24-week in-person behavioral weight control program and were asked to self-monitor their diet and exercise habits using the PDA. Basal metabolic rate and physical activity level were estimated at baseline. Energy intake from 7-day electronic food records were collected within the first month of the weight-control program. As subjects were actively losing weight, Bandini's adjustments were used to correct self-reported energy intake for weight loss. In this group, where 41% of the subjects were categorized as low-energy reporters, the use of a PDA did not improve validity of energy reporting when compared to what is reported in the literature.

  4. Film piracy in the era of digital technology

    Directory of Open Access Journals (Sweden)

    Petrović Vukašin

    2015-01-01

    Full Text Available Reproduction of films in the era of analog technology has been connected with a number of difficulties, involving, inter alia, technically complex process of reproduction, as well as high cash expenditures. In that sense, the very analog technology presented a barrier to reproduction of films by unauthorized persons. By switching to digital technology, the reproduction of mentioned copyright works became much easier, in terms of enabling individuals to, with easily available and relatively cheap technical means, in a fast and high quality way, make a large number of film copies. Since the digital era reflects progress of technology in the field of reproduction and distribution of films, as well as copyright works in general, the introduction of new exclusive rights in copyright law is very significant, as well as narrowing the existing limitations of copyright law rights and extension of duration of the protection. Effective enforcement of copyright protection in the new conditions opened a range of numerous issues, out of which the question of piracy in the field of film production is one of the most important, which presented the motivation for the author to cover this issue.

  5. Wireless patient monitoring system for a moving-actuator type artificial heart.

    Science.gov (United States)

    Nam, K W; Chung, J; Choi, S W; Sun, K; Min, B G

    2006-10-01

    In this study, we developed a wireless monitoring system for outpatients equipped with a moving-actuator type pulsatile bi-ventricular assist device, AnyHeart. The developed monitoring system consists of two parts; a Bluetooth-based short-distance self-monitoring system that can monitor and control the operating status of a VAD using a Bluetooth-embedded personal digital assistant or a personal computer within a distance of 10 meters, and a cellular network-based remote monitoring system that can continuously monitor and control the operating status of AnyHeart at any location. Results of in vitro experiments demonstrate the developed system's ability to monitor the operational status of an implanted AnyHeart.

  6. Stability of tetraphenyl butadiene thin films in liquid xenon

    International Nuclear Information System (INIS)

    Sanguino, P.; Balau, F.; Botelho do Rego, A.M.; Pereira, A.; Chepel, V.

    2016-01-01

    Tetraphenyl butadiene (TPB) is widely used in particle detectors as a wavelength shifter. In this work we studied the stability of TPB thin films when immersed in liquid xenon (LXe). The thin films were deposited on glass and quartz substrates by thermal evaporation. Morphological and chemical surface properties were monitored before and after immersion into LXe by scanning electron microscopy and X-ray photoelectron spectroscopy. No appreciable changes have been detected with these two methods. Grain size and surface chemical composition were found to be identical before and after submersion into LXe. However, the film thickness, measured via optical transmission in the ultraviolet–visible wavelength regions, decreased by 1.6 μg/cm 2 (24%) after immersion in LXe during 20 h. These results suggest the necessity of using a protective thin film over the Tetraphenyl butadiene when used as a wavelength shifter in LXe particle detectors. - Highlights: • Stability of tetraphenyl butadiene (TPB) thin films immersed in liquid xenon (LXe). • Thermally evaporated TPB thin films were immersed in LXe for 20 h. • Film morphology and chemical surface properties remained unchanged. • Surface density of the films decreased by 1.6 μg/cm 2 (24%) after immersion in LXe. • For using in LXe particle detectors, TPB films should be protected with a coating.

  7. Personal monitoring of 218Po and 214Po radionuclide deposition onto individuals under normal environmental exposure conditions

    International Nuclear Information System (INIS)

    Eatough, J.P.; Worley, A.; Moss, G.R.

    1999-01-01

    Personal dosemeters have been utilized to monitor the deposition of the radon decay products 218 Po and 214 Po onto individuals under normal environmental exposure conditions. Each detector consists of TASTRAK alpha-sensitive plastic incorporated into an ordinary working wristwatch. Subsequent analysis provides energy discrimination of the detected alpha-particle decays, and allows events from the individual radon decay products 218 Po and 214 Po, attached to the detector surface, to be uniquely identified. Assuming similar deposition onto skin and detector surfaces, the activity per unit area of deposited radionuclides can be determined for exposed skin. Forty-one personal dosemeters were issued to volunteers selected through the hospital medical physics departments at Reading, Northampton, Exeter and Plymouth. Each volunteer was also issued with a personal radon dosemeter to determine their individual radon exposure. The volunteers wore the two dosemeters simultaneously and continuously for a period of around one month. Correlations were observed between the radon exposure of the individual and the activity per unit area of 218 Po and 214 Po on the detector surface. From these correlations it can be estimated that at the UK average radon exposure of 20 Bq m -3 , the number of decays/cm 2 /year on continuously exposed skin surface is between 3500 and 28 000 for 218 Po, and between 7000 and 21 000 for 214 Po. These results can be combined with theoretical modelling of the dose distribution in the skin to yield the alpha-particle radiation dose to any identified target cells. (author)

  8. Incorporation of personal computers in a research reactor instrumentation system for data monitoring and analysis

    International Nuclear Information System (INIS)

    Leopando, L.S.

    1998-01-01

    The research contract was implemented by obtaining off-the shelf personal computer hardware and data acquisition cards, designing the interconnection with the instrumentation system, writing and debugging the software, and the assembling and testing the set-up. The hardware was designed to allow all variables monitored by the instrumentation system to be accessible to the computers, without requiring any major modification of the instrumentation system and without compromising reactor safety in any way. The computer hardware addition was also designed to have no effect on any existing function of the instrumentation system. The software was designed to implement only graphical display and automated logging of reactor variables. Additional functionality could be easily added in the future with software revision because all the reactor variables are already available in the computer. It would even be possible to ''close the loop'' and control the reactor through software. It was found that most of the effort in an undertaking of this sort will be in software development, but the job can be done even by non-computer specialized reactor people working with programming languages they are already familiar with. It was also found that the continuing rapid advance of personal computer technology makes it essential that such a project be undertaken with inevitability of future hardware upgrading in mind. The hardware techniques and the software developed may find applicability in other research reactors, especially those with a generic analog research reactor TRIGA console. (author)

  9. Space Station personal hygiene study

    Science.gov (United States)

    Prejean, Stephen E.; Booher, Cletis R.

    1986-01-01

    A personal hygiene system is currently under development for Space Station application that will provide capabilities equivalent to those found on earth. This paper addresses the study approach for specifying both primary and contingency personal hygiene systems and provisions for specified growth. Topics covered are system definition and subsystem descriptions. Subsystem interfaces are explored to determine which concurrent NASA study efforts must be monitored during future design phases to stay up-to-date on critical Space Station parameters. A design concept for a three (3) compartment personal hygiene facility is included as a baseline for planned test and verification activities.

  10. A survey of an air monitoring program

    International Nuclear Information System (INIS)

    Lee, M.B.

    1997-01-01

    The objective of this report is to compare personal air sampling data to stationary air sampling data and to bioassay data that was taken during the decontamination and decommissioning of sixty-one plutonium glove boxes at Argonne National Laboratory (ANL) in 1995. An air monitoring program administered at Argonne National Laboratory was assessed by comparing personal air sampler (PAS) data, stationary air sampler (SAS) data, and bioassay data. The study revealed that the PAS and SAS techniques were equivalent when averaged over all employees and all workdays, but the standard deviation was large. Also, large deviations were observed in individual samples. The correlation between individual PAS results and bioassay results was low. Personal air samplers and bioassay monitoring played complementary roles in assessing the workplace and estimating intakes. The PAS technique is adequate for detection and evaluation of contaminated atmospheres, whereas bioassay monitoring is better for determining individual intakes

  11. Mott-Schottky analysis of thin ZnO films

    International Nuclear Information System (INIS)

    Windisch, Charles F. Jr.; Exarhos, Gregory J.

    2000-01-01

    Thin ZnO films, both native and doped with secondary metal ions, have been prepared by sputter deposition and also by casting from solutions containing a range of precursor salts. The conductivity and infrared reflectivity of these films are subsequently enhanced chemically following treatment in H 2 gas at 400 degree sign C or by cathodic electrochemical treatment in a neutral (pH=7) phosphate buffer solution. While Hall-type measurements usually are used to evaluate the electrical properties of such films, the present study investigated whether a conventional Mott-Schottky analysis could be used to monitor the change in concentration of free carriers in these films before and after chemical and electrochemical reduction. The Mott-Schottky approach would be particularly appropriate for electrochemically modified films since the measurements could be made in the same electrolyte used for the post-deposition electrochemical processing. Results of studies on sputtered pure ZnO films in ferricyanide solution were promising. Mott-Schottky plots were linear and gave free carrier concentrations typical for undoped semiconductors. Film thicknesses estimated from the Mott-Schottky data were also reasonably close to thicknesses calculated from reflectance measurements. Studies on solution-deposited films were less successful. Mott-Schottky plots were nonlinear, apparently due to film porosity. A combination of dc polarization and atomic force microscopy measurements confirmed this conclusion. The results suggest that Mott-Schottky analysis would be suitable for characterizing solution-deposited ZnO films only after extensive modeling was performed to incorporate the effects of film porosity on the characteristics of the space-charge region of the semiconductor. (c) 2000 American Vacuum Society

  12. Solid-phase photocatalytic degradation of polyethylene film with manganese oxide OMS-2

    Science.gov (United States)

    Liu, Guanglong; Liao, Shuijiao; Zhu, Duanwei; Cui, Jingzhen; Zhou, Wenbing

    2011-01-01

    Solid-phase photocatalytic degradation of polyethylene (PE) film with cryptomelane-type manganese oxide (OMS-2) as photocatalyst was investigated in the ambient air under ultraviolet and visible light irradiation. The properties of the composite films were compared with those of the pure PE film through performing weight loss monitoring, IR spectroscopy, scanning electron microscopic (SEM) and X-ray photoelectron spectroscopy (XPS). The photoinduced degradation of PE-OMS-2 composite films was higher than that of the pure films, while there has been little change under the visible light irradiation. The weight loss of PE-OMS-2 (1.0 wt%) composite films steadily decreased and reached 16.5% in 288 h under UV light irradiation. Through SEM observation there were some cavities on the surface of composite films, but few change except some surface chalking phenomenon occurred in pure PE film. The degradation rate with ultraviolet irradiation is controllable by adjusting the content of OMS-2 particles in PE plastic. Finally, the mechanism of photocatalytic degradation of the composite films was briefly discussed.

  13. Importance of the personal endotoxin cloud in school-age children with asthma.

    Science.gov (United States)

    Rabinovitch, Nathan; Liu, Andrew H; Zhang, Lening; Rodes, Charles E; Foarde, Karin; Dutton, Steven J; Murphy, James R; Gelfand, Erwin W

    2005-11-01

    A number of studies have observed associations between the amount of endotoxin in urban dust and chronic asthma severity, but a direct relationship between personal exposure to household endotoxin and acute asthma worsening has not yet been defined. We sought to investigate the relationship between day-to-day changes in personal endotoxin exposure and asthma severity. In the winter and spring of 1999 through 2000, endotoxin exposures were monitored in asthmatic schoolchildren by using portable, as opposed to stationary, monitors designed to measure inhalable and respirable particulate matter less than or equal to 2.5 and 10 microm in diameter. Children were followed with daily measurements of FEV(1) and asthma symptoms. Over a 24-hour period, median daily personal endotoxin exposures ranged from 0.08 EU/m(3) (measured at a particulate matter size range Personal exposures were significantly (P personal activities might be better correlated with disease severity. Increases in personal endotoxin exposures were associated with decreased FEV(1) values and increased symptoms. These findings demonstrate the importance of using personal monitoring to both measure and correlate endotoxin exposure with asthma severity.

  14. Controlled Sharing of Personal Information in Android

    OpenAIRE

    Bø, Solvår; Pedersen, Stian; Nyre, Åsmund Ahlmann; Bernsmed, Karin

    2011-01-01

    Smartphones with third-party applications have become very popular. Recently, they have received attention for quietly monitoring and transferring personal information without the users’ knowledge. The objective of this work is to help users to protect their privacy by increasing their consciousness on how personal information is collected and distributed. We propose a design that provides a higher degree of control by allowing users to set preferences that determine what personal information...

  15. Monitoring occupational exposure to ionizing radiation

    International Nuclear Information System (INIS)

    Button, J.B.C.

    1997-01-01

    A brief overview is presented of methods of monitoring occupational exposure to ionizing radiation together with reasons for such monitoring and maintaining dose histories of radiation occupationally exposed persons. The various Australian providers of external radiation monitoring services and the types of dosemeters they supply are briefly described together with some monitoring results. Biological monitoring methods, are used to determine internal radiation dose. Whole body monitors, used for this purpose are available at Australian Radiation Lab., ANSTO and a few hospitals. Brief mention is made of the Australian National Radiation Dose Register and its objectives

  16. Inactivation of viruses in bubbling processes utilized for personal bioaerosol monitoring.

    Science.gov (United States)

    Agranovski, I E; Safatov, A S; Borodulin, A I; Pyankov, O V; Petrishchenko, V A; Sergeev, A N; Agafonov, A P; Ignatiev, G M; Sergeev, A A; Agranovski, V

    2004-12-01

    A new personal bioaerosol sampler has recently been developed and evaluated for sampling of viable airborne bacteria and fungi under controlled laboratory conditions and in the field. The operational principle of the device is based on the passage of air through porous medium immersed in liquid. This process leads to the formation of bubbles within the filter as the carrier gas passes through and thus provides effective mechanisms for aerosol removal. As demonstrated in previous studies, the culturability of sampled bacterium and fungi remained high for the entire 8-h sampling period. The present study is the first step of the evaluation of the new sampler for monitoring of viable airborne viruses. It focuses on the investigation of the inactivation rate of viruses in the bubbling process during 4 h of continuous operation. Four microbes were used in this study, influenza, measles, mumps, and vaccinia viruses. It was found that the use of distilled water as the collection fluid was associated with a relatively high decay rate. A significant improvement was achieved by utilizing virus maintenance fluid prepared by using Hank's solution with appropriate additives. The survival rates of the influenza, measles, and mumps viruses were increased by 1.4 log, 0.83 log, and 0.82 log, respectively, after the first hour of operation compared to bubbling through the sterile water. The same trend was observed throughout the entire 4-h experiment. There was no significant difference observed only for the robust vaccinia virus.

  17. Detection of narcotics with an immunoassay film badge

    International Nuclear Information System (INIS)

    Lukens, H.R.

    1993-01-01

    Efficient personnel performance, a major requirement for a safe nuclear industry, is jeopardized where personnel use narcotics. However, detection of narcotics at nuclear plants is a challenge. The unique specificity and sensitivity of an immunoassay has been implemented in the form of a small, dry immunoassay film badge (IFB) for the detection of vapors emitted by narcotics. The device is suitable as an area monitor, and its characteristics are suitable for use as a breath monitor for the detection of drug use

  18. Preparation and Analysis of Platinum Thin Films for High Temperature Sensor Applications

    Science.gov (United States)

    Wrbanek, John D.; Laster, Kimala L. H.

    2005-01-01

    A study has been made of platinum thin films for application as high temperature resistive sensors. To support NASA Glenn Research Center s high temperature thin film sensor effort, a magnetron sputtering system was installed recently in the GRC Microsystems Fabrication Clean Room Facility. Several samples of platinum films were prepared using various system parameters to establish run conditions. These films were characterized with the intended application of being used as resistive sensing elements, either for temperature or strain measurement. The resistances of several patterned sensors were monitored to document the effect of changes in parameters of deposition and annealing. The parameters were optimized for uniformity and intrinsic strain. The evaporation of platinum via oxidation during annealing over 900 C was documented, and a model for the process developed. The film adhesion was explored on films annealed to 1000 C with various bondcoats on fused quartz and alumina. From this compiled data, a list of optimal parameters and characteristics determined for patterned platinum thin films is given.

  19. Size Effects on Deformation and Fracture of Scandium Deuteride Films.

    Energy Technology Data Exchange (ETDEWEB)

    Teresi, C. S. [Univ. of Minnesota, Minneapolis, MN (United States); Hintsala, E. [Univ. of Minnesota, Minneapolis, MN (United States); Hysitron, Inc., Eden Prairie, MN (United States); Adams, David P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Yang, Nancy Y. C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Kammler, Daniel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Moody, N. R. [Univ. of Minnesota, Minneapolis, MN (United States); Gerberich, W. W. [Univ. of Minnesota, Minneapolis, MN (United States)

    2017-07-01

    Metal hydride films have been observed to crack during production and use, prompting mechanical property studies of scandium deuteride films. The following focuses on elastic modulus, fracture, and size effects observed in the system for future film mechanical behavior modeling efforts. Scandium deuteride films were produced through the deuterium charging of electron beam evaporated scandium films using X-ray diffraction, scanning Auger microscopy, and electron backscatter diffraction to monitor changes in the films before and after charging. Scanning electron microscopy, nanoindentation, and focused ion beam machined micropillar compression tests were used for mechanical characterization of the scandium deuteride films. The micropillars showed a size effect for flow stress, indicating that film thickness is a relevant tuning parameter for film performance, and that fracture was controlled by the presence of grain boundaries. Elastic modulus was determined by both micropillar compression and nanoindentation to be approximately 150 GPa, Fracture studies of bulk film channel cracking as well as compression induced cracks in some of the pillars yielded a fracture toughness around 1.0 MPa-m1/2. Preliminary Weibull distributions of fracture in the micropillars are provided. Despite this relatively low value of fracture toughness, scandium deuteride micropillars can undergo a large degree of plasticity in small volumes and can harden to some degree, demonstrating the ductile and brittle nature of this material

  20. AN INTERNATIONAL COOPERATION BY USING AN ALL-ENCOMPASSING PASSIVE RADON MONITOR.

    Science.gov (United States)

    Tommasino, L; Chen, J; Falcomer, R; Janik, M; Kanda, R; DeFelice, F; Cardellini, F; Trevisi, R; Leonardi, F; Magnoni, M; Chiaberto, E; Agnesod, G; Ragani, M Faure; Espinosa, G; Golzarri, J; Kozak, K; Mazur, J

    2017-11-01

    The recently developed radon film-badge makes it possible to measure radon indoors, in soil, in water and/or in aqueous media (e.g. mud). As a result of its wide response linearity, this monitor has been successfully used to measure radon in-water with concentrations from 10 to ~10 000 Bq/L. By exploiting the unique characteristics of this badge, a mini-survey has been carried out by Health Canada in which radon in water was measured from 12 private wells, as well as in tap water originating from the Ottawa River. Due to the widespread interest of different laboratories in using these passive monitors, laboratories were provided with plastic films to construct their own badges by using in-house CR-39 detectors. Monitors were then irradiated by a known radon concentration at the National Institute of Radiation Metrology (ENEA)'s radon chamber and sent back to each laboratory for processing and counting. Even though these laboratories have been using different etching- and counting-procedures, the film-badge responses varied only within ~12%. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Multi-controller based 29 channel whole body portal monitor

    International Nuclear Information System (INIS)

    Dheeraj Reddy, J.; Narender Reddy, J.

    2004-01-01

    Portal Monitors are an essential part of personnel monitoring programme in any Nuclear Power Plant or Radiochemical/Reprocessing Plant. Compared to conventional Portal Monitors, whole-body Portals are preferred, for effective monitoring of entire body of the person being monitored for radioactive contamination. This is achieved by effectively distributing a large number of detectors on front/back of the person being monitored. The entry and exit for such Portals is usually side ways. The electronic system, designed essentially consists of powerful compact electronic circuits, comprising of three micro-controllers, a host of (32) 12C serial counters, other serial ADCs, DACs etc., apart from pulse processing, HV and LV circuits. Built-in embedded code has powerful fault diagnostics routines to show up failures in detector / detector electronics, HV, LV and other circuits apart from indicating contamination status, through visual and aural indications such as MIMIC, visual LCD display and individual channel counts etc. The Portal structural design consists of four individual SS members integrated, lead shielding assemblies (inside), on hinged support frames facilitate ease of assembling and dismantling of the structure. The detector arrangement is so arranged to have optimal uniform spread out, so as to record contamination of the whole body of the person being monitored. (author)

  2. Harmonisation (legal, dosimetric, quality aspects) of individual monitoring, and integration of monitoring for external and internal exposures (EURADOS working group)

    International Nuclear Information System (INIS)

    Lopez, M.A.; Currivan, L.; Falk, R.; Olko, P.; Wernli, C.; Castellani, C.M.; Dijk, J.W.E. van

    2003-01-01

    The EURADOS Working Group II on 'Harmonisation of individual monitoring' consists of experts from almost all EU Member States and Newly Associated States (NAS), involved in tasks related to the assessment of doses for internal and external radiation. The final objective is to achieve harmonisation in individual monitoring for occupational exposures. Sub-group 2 activities are focused on investigating how the results from personal dosemeters for external radiation and workplace monitoring and from monitoring for internal exposure can be combined into a complete and consistent system of individual monitoring. Three questionnaires were prepared, covering Individual monitoring of external radiation (Questionnaire 1), 'Internal exposure' (Questionnaire 2) and 'Natural sources of radiation at workplace' (Questionnaire 3). With the agreement of a 'contact-person' selected in each country, the distribution of the three EURADOS 2002 questionnaires was carried out by e-mail among the dosimetry facilities of 28 European countries. The preliminary results of these actions are presented here. (author)

  3. Detection of impact damage on thermal protection systems using thin-film piezoelectric sensors for integrated structural health monitoring

    Science.gov (United States)

    Na, Jeong K.; Kuhr, Samuel J.; Jata, Kumar V.

    2008-03-01

    Thermal Protection Systems (TPS) can be subjected to impact damage during flight and/or during ground maintenance and/or repair. AFRL/RXLP is developing a reliable and robust on-board sensing/monitoring capability for next generation thermal protection systems to detect and assess impact damage. This study was focused on two classes of metallic thermal protection tiles to determine threshold for impact damage and develop sensing capability of the impacts. Sensors made of PVDF piezoelectric film were employed and tested to evaluate the detectability of impact signals and assess the onset or threshold of impact damage. Testing was performed over a range of impact energy levels, where the sensors were adhered to the back of the specimens. The PVDF signal levels were analyzed and compared to assess damage, where digital microscopy, visual inspection, and white light interferometry were used for damage verification. Based on the impact test results, an assessment of the impact damage thresholds for each type of metallic TPS system was made.

  4. A model system to mimic environmentally active surface film roughness and hydrophobicity.

    Science.gov (United States)

    Grant, Jacob S; Shaw, Scott K

    2017-10-01

    This work presents the development and initial assessment of a laboratory platform to allow quantitative studies on model urban films. The platform consists of stearic acid and eicosane mixtures that are solution deposited from hexanes onto smooth, solid substrates. We show that this model has distinctive capabilities to better mimic a naturally occurring film's morphology and hydrophobicity, two important parameters that have not previously been incorporated into model film systems. The physical and chemical properties of the model films are assessed using a variety of analytical instruments. The film thickness and roughness are probed via atomic force microscopy while the film composition, wettability, and water uptake are analyzed by Fourier transform infrared spectroscopy, contact angle goniometry, and quartz crystal microbalance, respectively. Simulated environmental maturation is achieved by exposing the film to regulated amounts of UV/ozone. Ultimately, oxidation of the film is monitored by the analytical techniques mentioned above and proceeds as expected to produce a utile model film system. Including variable roughness and tunable surface coverage results in several key advantages over prior model systems, and will more accurately represent native urban film behavior. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Multimodal Neural Network for Overhead Person Re-identification

    DEFF Research Database (Denmark)

    Lejbølle, Aske Rasch; Nasrollahi, Kamal; Krogh, Benjamin

    2017-01-01

    Person re-identification is a topic which has potential to be used for applications within forensics, flow analysis and queue monitoring. It is the process of matching persons across two or more camera views, most often by extracting colour and texture based hand-crafted features, to identify...

  6. Systematic processing of the external individual monitoring data obtained by photographic film and capacitor dosemeters

    International Nuclear Information System (INIS)

    Krueger, F.; Shtuk, D.

    1983-01-01

    Individual radiation load measurements have been carried out both with photographic film and capacitor type dosemeters (CD). Systematic statistics methods were applied for the obtained data processing. The CD data were shown to exceed those measured with the film dosemeters. Specific features of the CD application are revealed that should be taken into account in practice [ru

  7. Microstructure and properties of manganese dioxide films prepared by electrodeposition

    International Nuclear Information System (INIS)

    Jacob, G. Moses; Zhitomirsky, I.

    2008-01-01

    Nanostructured manganese dioxide films were obtained by galvanostatic, pulse and reverse pulse electrodeposition from 0.01 to 0.1 M KMnO 4 solutions. The deposition yield was investigated by in situ monitoring the deposit mass using a quartz crystal microbalance (QCM). Obtained films were studied by electron microscopy, X-ray diffraction analysis, energy dispersive spectroscopy, thermogravimetric and differential thermal analysis. The QCM and electron microscopy data were utilized for the investigation of deposition kinetics and film formation mechanism. It was shown that the deposition rate and film microstructure could be changed by variation of deposition conditions. The method allowed the fabrication of dense or porous films. The thickness of dense films was limited to ∼0.1 μm due to the insulating properties of manganese dioxide and film cracking, attributed to drying shrinkage. Porous and crack-free 1-2 μm films were obtained using galvanostatic or reverse pulse deposition from 0.02 M KMnO 4 solutions. It was shown that film porosity is beneficial for the charge transfer during deposition and crack prevention in thick films. Moreover, porous nanostructured films showed good capacitive behavior for applications in electrochemical supercapacitors. The porous nanostructured films prepared in the reverse pulse regime showed higher specific capacitance (SC) compared to the SC of the galvanostatic films. The highest SC of 279 F/g in a voltage window of 1 V was obtained in 0.1 M Na 2 SO 4 solutions at a scan rate of 2 mV/s

  8. Materiomics for Oral Disease Diagnostics and Personal Health Monitoring: Designer Biomaterials for the Next Generation Biomarkers

    Science.gov (United States)

    Zhang, Wenjun; Wang, Ming L.; Khalili, Sammy

    2016-01-01

    Abstract We live in exciting times for a new generation of biomarkers being enabled by advances in the design and use of biomaterials for medical and clinical applications, from nano- to macro-materials, and protein to tissue. Key challenges arise, however, due to both scientific complexity and compatibility of the interface of biology and engineered materials. The linking of mechanisms across scales by using a materials science approach to provide structure–process–property relations characterizes the emerging field of ‘materiomics,’ which offers enormous promise to provide the hitherto missing tools for biomaterial development for clinical diagnostics and the next generation biomarker applications towards personal health monitoring. Put in other words, the emerging field of materiomics represents an essentially systematic approach to the investigation of biological material systems, integrating natural functions and processes with traditional materials science perspectives. Here we outline how materiomics provides a game-changing technology platform for disruptive innovation in biomaterial science to enable the design of tailored and functional biomaterials—particularly, the design and screening of DNA aptamers for targeting biomarkers related to oral diseases and oral health monitoring. Rigorous and complementary computational modeling and experimental techniques will provide an efficient means to develop new clinical technologies in silico, greatly accelerating the translation of materiomics-driven oral health diagnostics from concept to practice in the clinic. PMID:26760957

  9. USB-based radiation monitor

    International Nuclear Information System (INIS)

    Drndarevic, V.; Jevtic, N.; Djuric, R.

    2006-01-01

    The Universal Serial Bus has become a dominant interface for the connection of standard peripheral devices to a personal computer. This paper analyzes the possibilities of USB bus applications in the field of measurement and environmental monitoring. As a result, a gamma radiation monitor consisting of an USB-based universal peripheral device and a gamma probe with a GM counter, has been designed. For the interfacing monitor with the powerful and easy to use LabVIEW software package, an instrument driver as a set of virtual instruments has been developed. The proposed monitor is a flexible instrument which can be used for laboratory measurements, as an environmental radiation monitor or for training purposes. Connected to the laptop computer, the monitor becomes a portable instrument suitable for field measurements. Basic measurements and functionality properties of the radiation monitor are presented here

  10. Voices of nuclear power monitors in fiscal 1982

    International Nuclear Information System (INIS)

    1984-01-01

    The system of nuclear power monitors was set up to hear candid opinions, etc. from general people on nuclear power development and utilization, and reflect them to nuclear power administration. As the monitors, 416 persons were selected across the country. The results in fiscal 1982 are described. (1) Questionnaire survey: Of the 416, 314 persons answered the questionnaire conducted in March, 1983, on future energy, nuclear power development, nuclear power safety administration, and nuclear power P.R. activities. (2) Occasional voices of monitors: Of the total 74 opinions, etc. from the monitors in fiscal 1982, 31 concerned the nuclear power P.R. activities, followed by 16 on nuclear power development and utilization, and 12 on nuclear power administration. (Mori, K.)

  11. Development of a Personal Integrated Environmental Monitoring System

    Directory of Open Access Journals (Sweden)

    Man Sing Wong

    2014-11-01

    Full Text Available Environmental pollution in the urban areas of Hong Kong has become a serious public issue but most urban inhabitants have no means of judging their own living environment in terms of dangerous threshold and overall livability. Currently there exist many low-cost sensors such as ultra-violet, temperature and air quality sensors that provide reasonably accurate data quality. In this paper, the development and evaluation of Integrated Environmental Monitoring System (IEMS are illustrated. This system consists of three components: (i position determination and sensor data collection for real-time geospatial-based environmental monitoring; (ii on-site data communication and visualization with the aid of an Android-based application; and (iii data analysis on a web server. This system has shown to be working well during field tests in a bus journey and a construction site. It provides an effective service platform for collecting environmental data in near real-time, and raises the public awareness of environmental quality in micro-environments.

  12. Quality assurance for multileaf collimator with radiographic film exposed by slit beam

    International Nuclear Information System (INIS)

    Ma Jinli; Jiang Guoliang; Fu Xiaolong; Liao Yuan; Wu Kailiang; Zhou Lijun

    2004-01-01

    Objective: To evaluate the role of Kodak X-OMAT-V film exposed by slit beam in the check of various leaf positions of multileaf collimator(MLC), and to check the status of Varian 26 leaf pairs MLC in the Department of Radiation Oncology in Shanghai Cancer Hospital affiliated to Fudan University. Methods: At first, some position errors of different sizes were produced for different leaves so as to determine the minimal leaf position error that could be seen on film. Then, exposure conditions including the exposure dose and source to film distance were changed to find the optimal one. Finally, a Kodak X-OMAT-V film was exposed with a leaf sequence file which was designated randomly by a physicist with leaf position errors of different sizes. After the film was developed, two doctors and two physicists were invited to observe, on blind basis, in order to determine the sensitivity and specificity of the film in the check of leaf positions. Ultimately, leaf positions of the Varian 26 leaf pairs MLC were checked, in which way, the leaf motor status and the carriage stability were checked indirectly. Results: Leaf position errors no less than 0.2 mm could be found using Kodak X-OMAT-V film under the following conditions: source to film distance 100 cm, exposure dose 25 MU, which had been considered as the optimal exposure conditions. The sensitivity and specificity of this method were 73.4% and 96.4%. Any MLC leaf position errors more than 0.2 mm could not be detected. Thus, it was deemed that all leaf motors of the Varian 26 leaf pairs MLC were well in gear and the carriages were stable. Conclusions: MLC leaf position errors can be detected by Kodak X-OMAT-V film exposed by slit beam with high accuracy, but the ability to find leaf position errors with the naked eye may vary from person to person. It is proposed that the Kodak X-OMAT-V film exposed by slit beam be used to check the MLC leaf positions, i. e. the leaf motor status and carriage stability, at regular

  13. Modelling of Outer and Inner Film Oil Pressure for Floating Ring Bearing Clearance in Turbochargers

    International Nuclear Information System (INIS)

    Zhang Hao; Shi Zhanqun; Gu Fengshou; Ball, Andrew

    2011-01-01

    Floating ring bearing is widely used in turbochargers to undertake the extreme condition of high rotating speed and high operating temperature. It is also the most concerned by the designers and users alike due to its high failure rate and high maintenance cost. Any little clearance change may result in oil leakage, which in turn cause blue smoke or black smoke according to leakage types. However, there is no condition monitoring of this bearing because it is almost impossible to measure the clearance especially the inner clearance, in which the inner oil film directly bears the high speed rotation. In stead of measuring clearance directly, this paper has proposed a method that uses film pressure as a measure to monitor the bearing clearance and its variation. A non-linear mathematical model is developed by using Reynolds equations with non-linear oil film pressure. A full description of the outer and inner film is provided along both axial and radial directions. A numerical simulation is immediately carried out. Variable clearance changes are investigated using the mathematical model. Results show the relationship between clearance and film pressure.

  14. Effects of Gender Roles and Self Perceptions on Affective Reactions to Horror Films.

    Science.gov (United States)

    Mundorf, Norbert; And Others

    1989-01-01

    Examines responses to graphic horror films based on gender and personality variables. Results indicate that responses to horror movies are largely determined by gender-specific rules for social conduct. (MW)

  15. Monitoring occupational exposure to ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Button, J.B.C. [Radiation Safety Consultancy, Engadine, NSW (Australia)

    1997-12-31

    A brief overview is presented of methods of monitoring occupational exposure to ionizing radiation together with reasons for such monitoring and maintaining dose histories of radiation occupationally exposed persons. The various Australian providers of external radiation monitoring services and the types of dosemeters they supply are briefly described together with some monitoring results. Biological monitoring methods, are used to determine internal radiation dose. Whole body monitors, used for this purpose are available at Australian Radiation Lab., ANSTO and a few hospitals. Brief mention is made of the Australian National Radiation Dose Register and its objectives. 8 refs., 9 tabs.

  16. Oromucosal film preparations: points to consider for patient centricity and manufacturing processes.

    Science.gov (United States)

    Krampe, Raphael; Visser, J Carolina; Frijlink, Henderik W; Breitkreutz, Jörg; Woerdenbag, Herman J; Preis, Maren

    2016-01-01

    According to the European Pharmacopoeia, oromucosal films comprise mucoadhesive buccal films and orodispersible films. Both oral dosage forms receive considerable interest in the recent years as commercially available pharmaceutical products and as small scale personalized extemporaneous preparations. In this review, technological issues such as viscosity of the casting liquid, mechanical properties of the film, upscaling and the stability of the casting solution and produced films will be discussed. Furthermore, patient-related problems like appearance, mucosal irritation, taste, drug load, safety and biopharmaceutics are described. Current knowledge and directions for solutions are summarized. The viscosity of the casting solution is a key factor for producing suitable films. This parameter is amongst others dependent on the polymer and active pharmaceutical ingredient, and the further excipients that are used. For optimal patient compliance, an acceptable taste and palatability are desirable. Safe and inert excipients should be used and appropriate packaging should be provided to produced films. Absorption through the oral mucosa will vary for each active compound, formulation and patient, which gives rise to pharmacokinetic questions. Finally, the European Pharmacopoeia needs to specify methods, requirement and definitions for oromucosal film preparations based on bio-relevant data.

  17. Different relationships between personal exposure and ambient concentration by particle size.

    Science.gov (United States)

    Guak, Sooyoung; Lee, Kiyoung

    2018-04-06

    Ambient particulate matter (PM) concentrations at monitoring stations were often used as an indicator of population exposure to PM in epidemiological studies. The correlation between personal exposure and ambient concentrations of PM varied because of diverse time-activity patterns. The aim of this study was to determine the relationship between personal exposure and ambient concentrations of PM 10 and PM 2.5 with minimal impact of time-activity pattern on personal exposure. Performance of the MicroPEM, v3.2 was evaluated by collocation with central ambient air monitors for PM 10 and PM 2.5 . A field technician repeatedly conducted measurement of 24 h personal exposures to PM 10 and PM 2.5 with a fixed time-activity pattern of office worker over 26 days in Seoul, Korea. The relationship between the MicroPEM and the ambient air monitor showed good linearity. Personal exposure and ambient concentrations of PM 2.5 were highly correlated with a fixed time-activity pattern compared with PM 10 . The finding implied a high infiltration rate of PM 2.5 and low infiltration rate of PM 10 . The relationship between personal exposure and ambient concentrations of PM 10 and PM 2.5 was different for high level episodes. In the Asian dust episode, staying indoors could reduce personal exposure to PM 10 . However, personal exposure to PM 2.5 could not be reduced by staying indoors during the fine dust advisory episode.

  18. Nanocomposite films containing Au nanoparticles formed by electrochemical reduction of metal ions in the multilayer films as electrocatalyst for dioxygen reduction

    International Nuclear Information System (INIS)

    Huang Minghua; Shen Yan; Cheng Wenlong; Shao Yong; Sun Xuping; Liu Baifeng; Dong Shaojun

    2005-01-01

    Through electrostatic layer-by-layer assembly, AuCl 4 - anions and [tetrakis(N-methylpyridyl)porphyrinato] cobalt (CoTMPyP) cations were alternately deposited on indium tin oxide (ITO) substrates, and 4-aminobenzoic acid modified glassy carbon electrode. Electrochemical reduction of AuCl 4 - anions sandwiched between CoTMPyP layers leads to the in situ formation of Au nanoparticles in the multilayer films. Regular growth of the multilayer films is monitored by UV-vis spectroscopy. UV-vis spectroscopy, X-ray photoelectron spectroscopy and cyclic voltammetry confirm the formation of Au nanoparticles in the multilayer films after electrochemical reduction of AuCl 4 - anions. Atomic force spectroscopy verifies that the as-prepared Au nanoparticles are uniformly distributed with average particles diameters of 20-25 nm. The resulting composite films containing Au nanoparticles with high stability exhibit high electrocatalytic activity for the reduction of dioxygen. Rotating disk electrode voltammetry and rotating ring-disk electrode voltammetry demonstrate the Au nanoparticles-containing films can catalyze two-electron reduction of O 2 to H 2 O 2 in O 2 -saturated 0.1 M H 2 SO 4 solution

  19. Enhanced Sensitivity of Gas Sensor Based on Poly(3-hexylthiophene Thin-Film Transistors for Disease Diagnosis and Environment Monitoring

    Directory of Open Access Journals (Sweden)

    Marco R. Cavallari

    2015-04-01

    Full Text Available Electronic devices based on organic thin-film transistors (OTFT have the potential to supply the demand for portable and low-cost gadgets, mainly as sensors for in situ disease diagnosis and environment monitoring. For that reason, poly(3-hexylthiophene (P3HT as the active layer in the widely-used bottom-gate/bottom-contact OTFT structure was deposited over highly-doped silicon substrates covered with thermally-grown oxide to detect vapor-phase compounds. A ten-fold organochloride and ammonia sensitivity compared to bare sensors corroborated the application of this semiconducting polymer in sensors. Furthermore, P3HT TFTs presented approximately three-order higher normalized sensitivity than any chemical sensor addressed herein. The results demonstrate that while TFTs respond linearly at the lowest concentration values herein, chemical sensors present such an operating regime mostly above 2000 ppm. Simultaneous alteration of charge carrier mobility and threshold voltage is responsible for pushing the detection limit down to units of ppm of ammonia, as well as tens of ppm of alcohol or ketones. Nevertheless, P3HT transistors and chemical sensors could compose an electronic nose operated at room temperature for a wide range concentration evaluation (1–10,000 ppm of gaseous analytes. Targeted analytes include not only biomarkers for diseases, such as uremia, cirrhosis, lung cancer and diabetes, but also gases for environment monitoring in food, cosmetic and microelectronics industries.

  20. Perpendicular Structure Formation of Block Copolymer Thin Films during Thermal Solvent Vapor Annealing: Solvent and Thickness Effects

    Directory of Open Access Journals (Sweden)

    Qiuyan Yang

    2017-10-01

    Full Text Available Solvent vapor annealing of block copolymer (BCP thin films can produce a range of interesting morphologies, especially when the perpendicular orientation of micro-domains with respect to the substrate plays a role. This, for instance, allows BCP thin films to serve as useful templates for nanolithography and hybrid materials preparation. However, precise control of the arising morphologies is essential, but in most cases difficult to achieve. In this work, we investigated the solvent and thickness effects on the morphology of poly(styrene-b-2 vinyl pyridine (PS-b-P2VP thin films with a film thickness range from 0.4 L0 up to 0.8 L0. Ordered perpendicular structures were achieved. One of the main merits of our work is that the phase behavior of the ultra-high molecular weight BCP thin films, which hold a 100-nm sized domain distance, can be easily monitored via current available techniques, such as scanning electron microscope (SEM, atomic force microscope (AFM, and transmission electron microscope (TEM. Systematic monitoring of the self-assembly behavior during solvent vapor annealing can thus provide an experimental guideline for the optimization of processing conditions of related BCP films systems.

  1. Occupational radiation exposure in the GDR in 1977

    International Nuclear Information System (INIS)

    Poulheim, K.F.; Rothe, W.; Scheler, R.

    1980-01-01

    In 1977, radiation workers were monitored for external and internal radiation exposure on the basis of film badges (37,348 persons), measurements with a whole-body counter (198 persons) and analyses of biosamples (174 persons). According to the film badge data, the monthly over-exposures (more than 4 mGy) totalled 253. In 6 cases the monthly exposure exceeded 30 mGy and the 9 highest annual exposure values were in the range of 50 to 120 mGy. Also, annual collective and annual per caput doses have been given for the exposed population as a whole and some subgroups. Based on model considerations, the internal radiation exposure situation resulting from unintentional intakes of radionuclides has been assessed in terms of committed dose equivalents to members of two selected groups of radiation workers: (a) persons with more-than-average internal contamination levels; (b) persons subjected to frequent individual monitoring. Except for some organ doses, the individual radiation exposure was below one-tenth the maximum permissible dose. (author)

  2. Current Status of the Personal Monitoring in Japan After the Fukushima Accident

    International Nuclear Information System (INIS)

    Koguchi, Y.; Takeuchi, N.; Yamamoto, T.

    2013-01-01

    On 11 March 2011 Japan suffered a magnitude 9.0 earthquake. The 2011 Great East Japan Earthquake created a series of massive tsunami waves that struck to the east coast of Japan, causing serious damage to Fukushima Daiichi Nuclear Power Plants (NPPs). The radioactive materials such as 134Cs and 137Cs were released into the environment in widespread area of east Japan, especially Fukushima prefecture. Many people living in Fukushima prefecture especially parents of children up to junior high school age have been worrying about the effect of health risk by contaminated radioactive materials. In addition, the International Commission on Radiological Protection (ICRP) has recommended that the dose (effective dose) limits in planned exposure situation for public is 1 mSv in a single year. Therefore, the local governments in Fukushima prefecture have decided to measure the exposed dose using passive dosemeter for public especially children in order to the health risk assessment and the optimum planning of decontamination. The RPL glass dosemeter, we called Glass Badge, based on radiophotoluminescence (RPL) technology is one of suitable dosimeters for the personal monitoring. More than 300 000 Glass Badges were distributed in Fukushima area up to the end of 2012 since the Fukushima Daiichi NPPs accident. It is very easy to know the individual dose and also useful for the health risk assessment.(author)

  3. Neutron monitoring for radiological protection

    International Nuclear Information System (INIS)

    Gibson, J.A.B.

    1985-01-01

    Neutron monitoring is a subject of increasing general interest and considerable attention is being paid to the development of improved techniques and methods for neutron monitoring. The Agency, therefore, considered it important to prepare a guide on the subject of neutron monitoring for radiation protection purposes. The present Manual is intended for those persons or authorities in Member States, particularly developing countries, who are responsible for the organization of neutron monitoring programmes and practical neutron monitoring. This Manual consequently, deals with topics such as neutron dosimetry, sources of neutrons and neutron detection as well as field instruments and operational systems used in this context

  4. Personnel Neutron Monitoring at AB Atomenergi

    International Nuclear Information System (INIS)

    Hagsgaard, S.; Widell, C.O.

    1964-02-01

    The routine personnel monitoring of fast neutrons is carried out by the counting of tracks in a nuclear emulsion. The tracks are counted in a microscope on a projection screen. This is a very tedious job and is only done on irradiated films which are counted over 6 mm 2 . The irradiated films are selected according to the recorded dose on the gamma film. It is often difficult to tell how much the visible tracks have faded during a two-weeks period. Fortunately the fading does not often exceed 20 % for this period. If the dosimeter has been gamma-irradiated, it may be difficult to recognize the proton tracks. If the film is stored for some time before being developed, this gamma fog will to some extent fade away. For large neutron doses a foil activation dosimeter is used. This dosimeter consists of a cadmium-shielded phosphorus foil, a cadmium shielded gold foil and an unshielded gold foil. The phosphorus foil has to be counted shortly after exposure

  5. Personnel Neutron Monitoring at AB Atomenergi

    Energy Technology Data Exchange (ETDEWEB)

    Hagsgaard, S; Widell, C O

    1964-02-15

    The routine personnel monitoring of fast neutrons is carried out by the counting of tracks in a nuclear emulsion. The tracks are counted in a microscope on a projection screen. This is a very tedious job and is only done on irradiated films which are counted over 6 mm{sup 2}. The irradiated films are selected according to the recorded dose on the gamma film. It is often difficult to tell how much the visible tracks have faded during a two-weeks period. Fortunately the fading does not often exceed 20 % for this period. If the dosimeter has been gamma-irradiated, it may be difficult to recognize the proton tracks. If the film is stored for some time before being developed, this gamma fog will to some extent fade away. For large neutron doses a foil activation dosimeter is used. This dosimeter consists of a cadmium-shielded phosphorus foil, a cadmium shielded gold foil and an unshielded gold foil. The phosphorus foil has to be counted shortly after exposure.

  6. Overview of individual monitoring and calibration of radiation monitors in the country; Panorama da monitoração individual e calibração de monitores de radiação no país

    Energy Technology Data Exchange (ETDEWEB)

    Alencar, M.A.V.; Patrão, K.C.S.; Ferreira, P.R.R.; Matta, L.E.S.C.; Peres, S.S.; Silva, F.C.A. da, E-mail: vallim@ird.gov.br [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Since 1995, the Institute of Radioprotection and Dosimetry (IRD/CNEN-RJ) has been responsible for the certification of instrument calibration laboratories and monitoring of occupationally exposed individuals (IOE), as well as monitoring and auditing the activities of eleven individual monitoring services (SMIE) and six instrument calibration laboratories (LCI) in the country. The work presents an overview of the number of IOE monitored and calibrated radiation monitors, from 2008 to 2016. The data were obtained through a census with the SMIE and LCI. The results show that in this period there was an increase of around 47% in the total number of IOE monitored and approximately 40% in the number of instrument calibrations. It was also observed the reduction of dosimetric film use and the beginning of OSLD monitoring.

  7. Assessment of Pupils’ Personal Achievements

    Directory of Open Access Journals (Sweden)

    T. A. Strokova

    2012-01-01

    Full Text Available The implementation of the new state educational standards, based on the competence approach, requires some new criteria, procedures and diagnostic tools for estimating pupils’ personal achievements. However, there is a lack of necessary guidelines and recommendations for such objective evaluation and comparative analysis of the effectiveness of educational establishments. The urgent need for unified monitoring instruments induced the author to develop a criteria-diagnostic complex providing the options for evaluating the important personal development aspects – intellectual, value-oriented and moral. The author recommends a self-assessment method for evaluating the intellectual qualities (i.e. self-dependency, critical thinking, logics, flexibility, depth, originality, etc., intellectual competences, and moral traits. The method is based on the tests – «Pupil in his own eyes» and «Pupil in the expert teachers’ eyes». For examining the value orientation, the author takes the classical method by M. Rokich. The approbation of the complex evaluation method was carried out in Tyumen schools and lyceums regarding the last year pupils. The research findings and proposed assessment tools can be used by headmasters and school teachers for monitoring the pupils’ personal growth. 

  8. 46 CFR 197.540 - Determination of personal exposure.

    Science.gov (United States)

    2010-10-01

    ... repeated for the operation when there has been a change in the procedure, equipment, or work practices of... when personal exposure has returned to the level that existed before the emergency. There must be... monitoring upon reasonable belief that the PEL's are being exceeded. (e) Notification of exposure monitoring...

  9. A posture recognition based fall detection system for monitoring an elderly person in a smart home environment.

    Science.gov (United States)

    Yu, Miao; Rhuma, Adel; Naqvi, Syed Mohsen; Wang, Liang; Chambers, Jonathon

    2012-11-01

    We propose a novel computer vision based fall detection system for monitoring an elderly person in a home care application. Background subtraction is applied to extract the foreground human body and the result is improved by using certain post-processing. Information from ellipse fitting and a projection histogram along the axes of the ellipse are used as the features for distinguishing different postures of the human. These features are then fed into a directed acyclic graph support vector machine (DAGSVM) for posture classification, the result of which is then combined with derived floor information to detect a fall. From a dataset of 15 people, we show that our fall detection system can achieve a high fall detection rate (97.08%) and a very low false detection rate (0.8%) in a simulated home environment.

  10. Mobile phones as monitors of personal exposure to air pollution: Is this the future?

    Directory of Open Access Journals (Sweden)

    Mawutorli Nyarku

    Full Text Available Mobile phones have a large spectrum of applications, aiding in risk prevention and improving health and wellbeing of their owners. So far, however, they have not been used for direct assessment of personal exposure to air pollution. In this study, we comprehensively evaluated the first, and the only available, mobile phone-BROAD Life-equipped with air pollution sensors (PM2.5 and VOC, to answer the question whether this technology is a viable option in the quest of reducing the burden of disease to air pollution. We tested its performance, applicability and suitability for the purpose by subjecting it to varied concentrations of different types of aerosol particles (cigarette smoke, petrol exhaust and concrete dust and formaldehyde under controlled laboratory conditions, as well as to ambient particles during field measurements. Six reference instruments were used in the study: AEROTRAK Optical Particle Counter (OPC model number 9306, DustTrak, Aerodynamic Particle Counter (APS, Scanning Mobility Particle Sizer (SMPS, Tapered Element Oscillating Microbalance (TEOM and Formaldehyde Analyser. Overall, we found that the phone's response was linear at higher particle number concentrations in the chamber, above 5 and 10 μg m-3, for combustion and concrete dust particles, respectively, and for higher formaldehyde concentrations, making it potentially suitable for applications in polluted environments. At lower ambient concentrations of particles around 10 ug m-3 and 20 μg m-3 for PM2.5 and PM10, respectively, the phone's response was below its noise level, suggesting that it is not suitable for ambient monitoring under relatively clean urban conditions. This mobile phone has a number of limitations that may hinder its use in personal exposure and for continuous monitoring. Despite these limitations, it may be used for comparative assessments, for example when comparing outcomes of intervention measures or local impacts of air pollution sources. It

  11. Mobile phones as monitors of personal exposure to air pollution: Is this the future?

    Science.gov (United States)

    Nyarku, Mawutorli; Mazaheri, Mandana; Jayaratne, Rohan; Dunbabin, Matthew; Rahman, Md Mahmudur; Uhde, Erik

    2018-01-01

    Mobile phones have a large spectrum of applications, aiding in risk prevention and improving health and wellbeing of their owners. So far, however, they have not been used for direct assessment of personal exposure to air pollution. In this study, we comprehensively evaluated the first, and the only available, mobile phone—BROAD Life—equipped with air pollution sensors (PM2.5 and VOC), to answer the question whether this technology is a viable option in the quest of reducing the burden of disease to air pollution. We tested its performance, applicability and suitability for the purpose by subjecting it to varied concentrations of different types of aerosol particles (cigarette smoke, petrol exhaust and concrete dust) and formaldehyde under controlled laboratory conditions, as well as to ambient particles during field measurements. Six reference instruments were used in the study: AEROTRAK Optical Particle Counter (OPC model number 9306), DustTrak, Aerodynamic Particle Counter (APS), Scanning Mobility Particle Sizer (SMPS), Tapered Element Oscillating Microbalance (TEOM) and Formaldehyde Analyser. Overall, we found that the phone’s response was linear at higher particle number concentrations in the chamber, above 5 and 10 μg m-3, for combustion and concrete dust particles, respectively, and for higher formaldehyde concentrations, making it potentially suitable for applications in polluted environments. At lower ambient concentrations of particles around 10 ug m-3 and 20 μg m-3 for PM2.5 and PM10, respectively, the phone’s response was below its noise level, suggesting that it is not suitable for ambient monitoring under relatively clean urban conditions. This mobile phone has a number of limitations that may hinder its use in personal exposure and for continuous monitoring. Despite these limitations, it may be used for comparative assessments, for example when comparing outcomes of intervention measures or local impacts of air pollution sources. It should

  12. Mobile phones as monitors of personal exposure to air pollution: Is this the future?

    Science.gov (United States)

    Nyarku, Mawutorli; Mazaheri, Mandana; Jayaratne, Rohan; Dunbabin, Matthew; Rahman, Md Mahmudur; Uhde, Erik; Morawska, Lidia

    2018-01-01

    Mobile phones have a large spectrum of applications, aiding in risk prevention and improving health and wellbeing of their owners. So far, however, they have not been used for direct assessment of personal exposure to air pollution. In this study, we comprehensively evaluated the first, and the only available, mobile phone-BROAD Life-equipped with air pollution sensors (PM2.5 and VOC), to answer the question whether this technology is a viable option in the quest of reducing the burden of disease to air pollution. We tested its performance, applicability and suitability for the purpose by subjecting it to varied concentrations of different types of aerosol particles (cigarette smoke, petrol exhaust and concrete dust) and formaldehyde under controlled laboratory conditions, as well as to ambient particles during field measurements. Six reference instruments were used in the study: AEROTRAK Optical Particle Counter (OPC model number 9306), DustTrak, Aerodynamic Particle Counter (APS), Scanning Mobility Particle Sizer (SMPS), Tapered Element Oscillating Microbalance (TEOM) and Formaldehyde Analyser. Overall, we found that the phone's response was linear at higher particle number concentrations in the chamber, above 5 and 10 μg m-3, for combustion and concrete dust particles, respectively, and for higher formaldehyde concentrations, making it potentially suitable for applications in polluted environments. At lower ambient concentrations of particles around 10 ug m-3 and 20 μg m-3 for PM2.5 and PM10, respectively, the phone's response was below its noise level, suggesting that it is not suitable for ambient monitoring under relatively clean urban conditions. This mobile phone has a number of limitations that may hinder its use in personal exposure and for continuous monitoring. Despite these limitations, it may be used for comparative assessments, for example when comparing outcomes of intervention measures or local impacts of air pollution sources. It should be kept

  13. Disillusionment Trilogy: a Study of the Effects of Work-Related and Psychosocial Stress Through Film

    Directory of Open Access Journals (Sweden)

    Francisco José FERNÁNDEZ GALINDO

    2017-03-01

    Full Text Available Currently, disorders derived from work-related and psychosocial stress are increasingly important. Here the influence of professional activities on personal and family life and on the psyche is analysed by means of three films filmed in different periods: the North American The Arrangement (1969, the Spanish The Green Pastures (1979 and the Canadian The Age of Ignorance (2007.

  14. Dislocation/hydrogen interaction mechanisms in hydrided nanocrystalline palladium films

    International Nuclear Information System (INIS)

    Amin-Ahmadi, Behnam; Connétable, Damien; Fivel, Marc; Tanguy, Döme; Delmelle, Renaud; Turner, Stuart; Malet, Loic; Godet, Stephane; Pardoen, Thomas; Proost, Joris; Schryvers, Dominique

    2016-01-01

    The nanoscale plasticity mechanisms activated during hydriding cycles in sputtered nanocrystalline Pd films have been investigated ex-situ using advanced transmission electron microscopy techniques. The internal stress developing within the films during hydriding has been monitored in-situ. Results showed that in Pd films hydrided to β-phase, local plasticity was mainly controlled by dislocation activity in spite of the small grain size. Changes of the grain size distribution and the crystallographic texture have not been observed. In contrast, significant microstructural changes were not observed in Pd films hydrided to α-phase. Moreover, the effect of hydrogen loading on the nature and density of dislocations has been investigated using aberration-corrected TEM. Surprisingly, a high density of shear type stacking faults has been observed after dehydriding, indicating a significant effect of hydrogen on the nucleation energy barriers of Shockley partial dislocations. Ab-initio calculations of the effect of hydrogen on the intrinsic stable and unstable stacking fault energies of palladium confirm the experimental observations.

  15. Thermoluminescence in films of HfO2:Dy+3

    International Nuclear Information System (INIS)

    Ceron, P.; Rivera, T.; Guzman, J.; Montes, E.; Pelaez, A.; Rojas, B.; Guzman, D.; Azorin, J.; Paredes, L.

    2014-08-01

    In this work the thermoluminescence (TL) response of films of hafnium oxide polluted with dysprosium (HfO 2 :Dy +3 ) that were irradiated in the near UV (200 nm - 400 nm). The films were deposited by means of the ultrasonics spray pyrolysis technique on a glass substrate, using different deposit temperatures (300 grades C - 600 grades C). The best TL emission corresponded to the prepared film to 450 grades C that was exposed to a spectral irradiation of 80 μJ/(cm 2 -s) with a wave longitude of 240 nm. The TL response in function of the spectral irradiation was lineal in the studied interval (24 to 288 mJ/cm 2 ), several kinetic parameters were also calculated of the shine curve as depth of the trap (E), frequency factor (s) and order to the kinetics (b). The obtained results show that the films of HfO 2 :Dy +3 could be used as radiation monitor in the region of the near UV. (Author)

  16. Nostalgic [re]remembering: film fan cultures and the affective reiteration of popular film histories.

    Directory of Open Access Journals (Sweden)

    Nathan Hunt

    2011-05-01

    Full Text Available

    Abstract: This article explores two central uses of memory narratives in film fan culture: Firstly; that fan magazines recycle and reiterate popular histories of film, with the extensive detailing of anecdotes and histories of productions serving to fix certain texts as canonical, cult or classic film artefacts whilst legitimating nostalgia as a mode of reading; secondly; that such films are historically positioned in terms of an appeal to fans via nostalgia as activating personal and affective histories of pleasurable film reception. This piece examines the various ways that commercial magazines discursively utilise nostalgia in their mediation between texts, institutions and fan audiences. At the same time it also explores that way that nostalgia resonates within the activities and discourses of fans as they engage with film.

     

    Résumé: Cet article analyse deux usages fondamentaux des souvenirs narratifs dans la culture des fans cinématographiques. D'une part, le recyclage et la reprise d'histoires populaires sur le cinéma, notamment, avec la mention très détaillée d'anecdotes et d'histoires sur l'histoire de

  17. Communication plan of GPS monitoring system based on the Internet

    Science.gov (United States)

    Xing, Xiangpeng; Liu, Zhenan; Bao, Yuanlu

    2005-11-01

    In GPS monitoring system, wireless communications network is necessary to keep base station in contact with mobile stations. Public communications network and personal communications network can't work well all the time. In this article, an economical communications network that can be competent for communication of GPS monitoring system is introduced. Personal communications network is used in this GPS monitoring system. In order to enlarge the coverage area and to expand the capacity of the personal communications network, the concept of cellular radio system is introduced. Because only the non-adjacent cells can use the same frequency channel, handoff of mobile station is extremely important when it goes in another cell. The mobile station of the system will know its own longitude and latitude by receiving data from GPS satellites all the time, so it can change its working frequency channel according to its position. Internet, instead of personal communication cable, is used to connect the base stations. So the communications network has the advantage of public communications network and personal one.

  18. Demonizing in children's television cartoons and Disney animated films.

    Science.gov (United States)

    Fouts, Gregory; Callan, Mitchell; Piasentin, Kelly; Lawson, Andrea

    2006-01-01

    The purpose of this study was to assess the prevalence of demonizing in the two major media that young children use (television and movies). Two content analyses were conducted using the animated feature films (n = 34) of the Walt Disney Company and after-school cartoons (n = 41). Each was coded for the modeling of the use of "evil" words when referring to a person, e.g., monster, devil, demon, wicked. Seventy-four percent of the Disney films contained "evil" references, with an average of 5.6 references per film. Forty-four percent of the after-school cartoons contained "evil" references, with an average of one per cartoon. The results are discussed within the context of children's repeated exposure to popular animated movies and cartoons and their learning to demonize people who engage in perceived "bad" behaviors.

  19. Using a personal watercraft for monitoring bathymetric changes at storm scale

    NARCIS (Netherlands)

    Van Son, S.T.J.; Lindenbergh, R.C.; De Schipper, M.A.; De Vries, S.; Duijnmayer, K.

    2009-01-01

    Monitoring and understanding coastal processes is important for the Netherlands since the most densely populated areas are situated directly behind the coastal defense. Traditionally, bathymetric changes are monitored at annual intervals, although nowadays it is understood that most dramatic changes

  20. Personal Beacon

    Science.gov (United States)

    2000-01-01

    The MicroPLB (personal locator beacon) is a search and rescue satellite-aided tracking (SARSAT) transmitter. When activated it emits a distress signal to a constellation of internationally operated satellites. The endangered person's identity and location anywhere on Earth is automatically forwarded to central monitoring stations around the world. It is accurate to within just a few meters. The user uses the device to download navigation data from a global positioning satellite receiver. After the download is complete, the MicroPLB functions as a self-locating beacon. Also, it is the only PLB to use a safe battery. In the past, other PLB devices have used batteries that have enough volatility to explode with extreme force. It was developed by Microwave Monolithic, Inc. through SBIR funding from Glenn Research Center and Goddard Space Flight Center.

  1. Development of luminescent pH sensor films for monitoring bacterial growth through tissue.

    Science.gov (United States)

    Wang, Fenglin; Raval, Yash; Chen, Hongyu; Tzeng, Tzuen-Rong J; DesJardins, John D; Anker, Jeffrey N

    2014-02-01

    Although implanted medical devices (IMDs) offer many benefits, they are susceptible to bacterial colonization and infections. Such infections are difficult to treat because bacteria could form biofilms on the implant surface, which reduce antibiotics penetration and generate local dormant regions with low pH and low oxygen. In addition, these infections are hard to detect early because biofilms are often localized on the surface. Herein, an optical sensor film is developed to detect local acidosis on an implanted surface. The film contains both upconverting particles (UCPs) that serve as a light source and a pH indicator that alters the luminescence spectrum. When irradiated with 980 nm light, the UCPs produce deeply penetrating red light emission, while generating negligible autofluorescence in the tissue. The basic form of the pH indicator absorbs more of upconversion luminescence at 661 nm than at 671 nm and consequently the spectral ratio indicates pH. Implanting this pH sensor film beneath 6-7 mm of porcine tissue does not substantially affect the calibration curve because the peaks are closely spaced. Furthermore, growth of Staphylococcus epidermidis on the sensor surface causes a local pH decrease that can be detected non-invasively through the tissue. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Dense zig-zag microstructures in YSZ thin films by pulsed laser deposition

    Science.gov (United States)

    Stender, Dieter; Schäuble, Nina; Weidenkaff, Anke; Montagne, Alex; Ghisleni, Rudy; Michler, Johann; Schneider, Christof W.; Wokaun, Alexander; Lippert, Thomas

    2015-01-01

    The very brittle oxygen ion conductor yttria stabilized zirconia (YSZ) is a typical solid electrolyte for miniaturized thin film fuel cells. In order to decrease the fuel cell operating temperature, the thickness of yttria stabilized zirconia thin films is reduced. Often, these thin membranes suffer from mechanical failure and gas permeability. To improve these mechanical issues, a glancing angle deposition approach is used to grow yttria stabilized zirconia thin films with tilted columnar structures. Changes of the material flux direction during the deposition result in a dense, zigzag-like structure with columnar crystallites. This structure reduces the elastic modulus of these membranes as compared to columnar yttria stabilized zirconia thin films as monitored by nano-indentation which makes them more adaptable to applied stress.

  3. Dense zig-zag microstructures in YSZ thin films by pulsed laser deposition

    Directory of Open Access Journals (Sweden)

    Dieter Stender

    2015-01-01

    Full Text Available The very brittle oxygen ion conductor yttria stabilized zirconia (YSZ is a typical solid electrolyte for miniaturized thin film fuel cells. In order to decrease the fuel cell operating temperature, the thickness of yttria stabilized zirconia thin films is reduced. Often, these thin membranes suffer from mechanical failure and gas permeability. To improve these mechanical issues, a glancing angle deposition approach is used to grow yttria stabilized zirconia thin films with tilted columnar structures. Changes of the material flux direction during the deposition result in a dense, zigzag-like structure with columnar crystallites. This structure reduces the elastic modulus of these membranes as compared to columnar yttria stabilized zirconia thin films as monitored by nano-indentation which makes them more adaptable to applied stress.

  4. Synergistic Impact of Solvent and Polymer Additives on the Film Formation of Small Molecule Blend Films for Bulk Heterojunction Solar Cells

    KAUST Repository

    McDowell, Caitlin

    2015-07-14

    The addition of polystyrene (PS), a typical insulator, is empirically shown to increase the power conversion efficiencies (PCEs) of a solution-deposited bulk heterojunction (BHJ) molecular blend film used in solar cell fabrication: p-DTS(FBTTh2)2/PC71BM. The performance is further improved by small quantities of diiodooctane (DIO), an established solvent additive. In this study, how the addition of PS and DIO affects the film formation of this bulk heterojunction blend film are probed via in situ monitoring of absorbance, thickness, and crystallinity. PS and DIO additives are shown to promote donor crystallite formation on different time scales and through different mechanisms. PS-containing films retain chlorobenzene solvent, extending evaporation time and promoting phase separation earlier in the casting process. This extended time is insufficient to attain the morphology for optimal PCE results before the film sets. Here is where the presence of DIO comes into play: its low vapor pressure further extends the time scale of film evolution and allows for crystalline rearrangement of the donor phase long after casting, ultimately leading to the best BHJ organization. In situ measurement shows that polystyrene (PS) and diiodooctane (DIO) additives promote donor crystallite formation synergistically, on different time scales, and through different mechanisms. PS-rich films retain solvent, promoting phase separation early in the casting process. Meanwhile, the low vapor pressure of DIO extends the time scale of film evolution and allows for crystalline rearrangement of the donor phase after casting. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Reversible Formation of Silver Clusters and Particles in Polymer Films

    National Research Council Canada - National Science Library

    Gaddy, G. A; Korchev, A. S; McLain, Jason L; Black, J. R; Mills, German; Bratcher, Matthew S; Slaten, B. L

    2004-01-01

    .... The formation of Ag clusters and particles is monitored using UV-VIS spectroscopy. Films treated with H2O2 exhibit bleaching of the UV-VIS signals corresponding to Ag clusters and Ag particles that were generated during the photo reduction...

  6. Development of a metrology method for composition and thickness of barium strontium titanate thin films

    International Nuclear Information System (INIS)

    Remmel, Thomas; Werho, Dennis; Liu, Ran; Chu, Peir

    1998-01-01

    Thin films of barium strontium titanate (BST) are being investigated as the charge storage dielectric in advanced memory devices, due to their promise for high dielectric constant. Since the capacitance of BST films is a function of both stoichiometry and thickness, implementation into manufacturing requires precise metrology methods to monitor both of these properties. This is no small challenge, considering the BST film thicknesses are 60 nm or less. A metrology method was developed based on X-ray Fluorescence and applied to the measurement of stoichiometry and thickness of BST thin films in a variety of applications

  7. Use of remote monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Fournel, E; Gouilloux, C

    1977-01-01

    Paper traces the development of remote monitoring devices, since their first appearance for safety purposes. Discusses their uses in coal mines: working and safety (definitions); sources and channels of information (transmission of information by automatic or verbal means); mine control stations; duties and responsibilities of persons in charge. Examines the contribution made by remote monitoring to management in production sector. Gives examples of assistance given to production management showing a very advantageous result on balance, by their use. The use of computers in real time and in batched mode is compared. Discusses their use in monitoring mine atmosphere. Very favorable results have already been obtained in France and abroad. The broadening scope and future of remote monitoring is considered.

  8. A clinical trial of a rare earth screen/film system in a periapical cassette

    International Nuclear Information System (INIS)

    Kogon, S.L.; Stephens, R.G.; Reid, J.A.; Lubus, N.J.

    1984-01-01

    In a clinical trial, a slow rare earth screen/film system (Siemens Titan 2D/Kodak XG) was used to obtain intraoral radiographs at conventional monitoring stages in endodontic treatment. The screen film image proved to be an effective substitute for the direct-exposure Ultraspeed periapical film. The intraoral cassettes, designed and fabricated for the study, were an adaptation of the flexible, vacuum-sealed cassettes used in mammography. It is believed that when a practicable periapical cassette is manufactured, many additional indications for the system are probable. Major reductions in patient exposure of at least 85% to 90% per periapical film would be effected

  9. Aerosol deposition of (Cu,Ti) substituted bismuth vanadate films

    Energy Technology Data Exchange (ETDEWEB)

    Exner, Jörg, E-mail: Functional.Materials@Uni-Bayreuth.de [University of Bayreuth, Department of Functional Materials, Universitätsstraße 30, 95440 Bayreuth (Germany); Fuierer, Paul [Materials and Metallurgical Engineering Department, New Mexico Institute of Mining and Technology, Socorro, NM 87801 (United States); Moos, Ralf [University of Bayreuth, Department of Functional Materials, Universitätsstraße 30, 95440 Bayreuth (Germany)

    2014-12-31

    Bismuth vanadate, Bi{sub 4}V{sub 2}O{sub 11}, and related compounds with various metal (Me) substitutions, Bi{sub 4}(Me{sub x}V{sub 1−x}){sub 2}O{sub 11−δ}, show some of the highest ionic conductivities among the known solid oxide electrolytes. Films of Cu and Ti substituted bismuth vanadate were prepared by an aerosol deposition method, a spray coating process also described as room temperature impact consolidation. Resultant films, several microns in thickness, were dense with good adhesion to the substrate. Scanning electron microscopy and high temperature X-ray diffraction were used to monitor the effects of temperature on the structure and microstructure of the film. The particle size remained nano-scale while microstrain decreased rapidly up to 500 °C, above which coarsening and texturing increased rapidly. Impedance measurements of films deposited on inter-digital electrodes revealed an annealing effect on the ionic conductivity, with the conductivity exceeding that of a screen printed film, and approaching that of bulk ceramic. - Highlights: • Cu and Ti doped bismuth vanadate films were prepared by aerosol deposition (AD). • Dense 3–5 μm thick films were deposited on alumina, silicon and gold electrodes. • Annealing of the AD-layer increases the conductivity by 1.5 orders of magnitude. • Effect of temperature on structure and microstructure was investigated.

  10. Influence of colorant and film thickness on thermal aging characteristics of oxo-biodegradable plastic bags

    Science.gov (United States)

    Leuterio, Giselle Lou D.; Pajarito, Bryan B.; Domingo, Carla Marie C.; Lim, Anna Patricia G.

    2016-05-01

    Functional, lightweight, strong and cheap plastic bags incorporated with pro-oxidants undergo accelerated degradation under exposure to heat and oxygen. This work investigated the effect of colorant and film thickness on thermal aging characteristics of commercial oxo-biodegradable plastic bag films at 70 °C. Degradation is monitored through changes in infrared absorption, weight, and tensile properties of thermally aged films. The presence of carbonyl band in infrared spectrum after 672 h of thermal aging supports the degradation behavior of exposed films. Results show that incorporation of colorant and increasing thickness exhibit low maximum weight uptake. Titanium dioxide as white colorant in films lowers the susceptibility of films to oxygen uptake but enhances physical degradation. Higher amount of pro-oxidant loading also contributes to faster degradation. Opaque films are characterized by low tensile strength and high elastic modulus. Decreasing the thickness contributes to lower tensile strength of films. Thermally aged films with colorant and low thickness promote enhanced degradation.

  11. Auger line shape changes in epitaxial (111)Pd/(111)Cu films

    Energy Technology Data Exchange (ETDEWEB)

    Chao, S S; Knabbe, E A; Vook, R W

    1980-01-01

    Epitaxial Pd films ranging in thickness from a few tenths of a monolayer up to many monolayers were formed on (111)Cu substrate films at room temperature under uhv conditions. The growth of these Pd films was monitored in situ by Auger electron spectroscopy. The line profiles of the Cu MMM (61 eV) and Pd MVV (329 eV) AES doublets varied significantly with the amount of Pd deposited. A new measure of the AES doublet line profile, called the R-factor, was defined. A graph of R/sub Pd/ versus Pd film thickness shows a sharp decline with increasing thickness. Superimposed on the major trends is a cyclical variation. A corresponding periodicity in R/sub Cu/ was observed for the Cu MMM (61 eV) AES doublet. The results suggest that the R-factor provides a direct measure of changes in the electronic structures of the overgrowth and substrate films as the former thickens by a layer-growth mechanism.

  12. Albumin adsorption on oxide thin films studied by spectroscopic ellipsometry

    Energy Technology Data Exchange (ETDEWEB)

    Silva-Bermudez, P., E-mail: suriel21@yahoo.com [Instituto de Investigaciones en Materiales, Universidad Nacional Autonoma de Mexico, Circuito Exterior s/n, C.U., 04510, Mexico D.F. (Mexico); Unidad de Posgrado, Facultad de Odontologia, Universidad Nacional Autonoma de Mexico, CU, 04510, Mexico D.F. (Mexico); Rodil, S.E.; Muhl, S. [Instituto de Investigaciones en Materiales, Universidad Nacional Autonoma de Mexico, Circuito Exterior s/n, C.U., 04510, Mexico D.F. (Mexico)

    2011-12-15

    Thin films of tantalum, niobium, zirconium and titanium oxides were deposited by reactive magnetron sputtering and their wettability and surface energy, optical properties, roughness, chemical composition and microstructure were characterized using contact angle measurements, spectroscopic ellipsometry, profilometry, X-ray photoelectron spectroscopy and X-ray diffraction, respectively. The purpose of the work was to correlate the surface properties of the films to the Bovine Serum Albumin (BSA) adsorption, as a first step into the development of an initial in vitro test of the films biocompatibility, based on standardized protein adsorption essays. The films were immersed into BSA solutions with different protein concentrations and protein adsorption was monitored in situ by dynamic ellipsometry; the adsorption-rate was dependent on the solution concentration and the immersion time. The overall BSA adsorption was studied in situ using spectroscopic ellipsometry and it was found to be influenced by the wettability of the films; larger BSA adsorption occurred on the more hydrophobic surface, the ZrO{sub 2} film. On the Ta{sub 2}O{sub 5}, Nb{sub 2}O{sub 5} and TiO{sub 2} films, hydrophilic surfaces, the overall BSA adsorption increased with the surface roughness or the polar component of the surface energy.

  13. Personality traits, self-care behaviours and glycaemic control in Type 2 diabetes

    DEFF Research Database (Denmark)

    Skinner, T. C.; Bruce, D. G.; Davis, T. M.E.

    2014-01-01

    Aims: To determine whether the personality traits of conscientiousness and agreeableness are associated with self-care behaviours and glycaemia in Type 2 diabetes. Methods: The Big Five Inventory personality traits Agreeableness, Conscientiousness, Extraversion, Neuroticism and Openness were...... modelling was used to determine whether personality was associated with BMI, smoking, self-monitoring of blood glucose and medication taking. Multivariable regression was used to investigate which traits were independently associated with these self-care behaviours and HbA1c. Results: Patients with higher......, longer diabetes duration, diabetes treatment, self-monitoring of blood glucose (negatively) and less medication taking (P ≤ 0.009), but no personality trait added to the model. Conclusions: Although there was no independent association between personality traits and HbA1c, the relationship between high...

  14. [Comparison of detectability of liquid crystal displays (LCDs) and film using phantoms of small adenocarcinomas as abnormalities].

    Science.gov (United States)

    Mochizuki, Yasuo; Abe, Shinji; Monma, Masahiko; Yamaguchi, Kojirou; Adachi, Toshiki

    2011-01-01

    Following the trend of the digitalization of the modalities used for diagnostic imaging, the devices for such imaging have increasingly included monitors. The present study was undertaken to evaluate the usefulness of soft-copy (liquid crystal display; LCD) images of phantoms of small adenocarcinomas using receiver operating characteristic (ROC) analysis of two different display systems: LCD and hard copy (film). A two-tailed paired t-test and the jackknife method (parametric methods) were performed, and no significant differences were found in the area under the ROC curve (AUC) for the pulmonary fields, lungs, ribs, or mediastinum between the film and LCD display systems, and the detectability did not differ between the film and LCD monitors. A Mann-Whitney U test, which is a non-parametric method that applies to the analysis of a small sample, also showed no significant differences in the AUC. The results of this study suggest that LCDs can replace hard-copy film as a display system if the signals.

  15. LGBT Monitor 2016

    NARCIS (Netherlands)

    Lisette Kuyper

    2016-01-01

    Original title: LHBT-monitor 2016 What is the public attitude today towards lesbian, homosexual, bisexual and transgender (LGBT) persons? What do large-scale population surveys enable us to say about their position in society? The Netherlands is one of the most positive countries in Europe in its

  16. An optically transparent, flexible, patterned and conductive silk biopolymer film (Conference Presentation)

    Science.gov (United States)

    Umar, Muhammad; Min, Kyungtaek; Kim, Sunghwan

    2017-02-01

    Transparent, flexible, and conducting films are of great interest for wearable electronics. For better biotic/abiotic interface, the films to integrate the electronics components requires the patterned surface conductors with optical transparency, smoothness, good electrical conductivity, along with the biofriendly traits of films. We focus on silk fibroin, a natural biopolymer extracted from the Bombyx mori cocoons, for this bioelectronics applications. Here we report an optically transparent, flexible, and patterned surface conductor on a silk film by burying a silver nanowires (AgNW) network below the surface of the silk film. The conducting silk film reveals high optical transparency of 80% and the excellent electronic conductivity of 15 Ω/sq, along with smooth surface. The integration of light emitting diode (LED) chip on the patterned electrodes confirms that the current can flow through the transparent and patterned electrodes on the silk film, and this result shows an application for integration of functional electronic/opto-electronic devices. Additionally, we fabricate a transparent and flexible radio frequency (RF) antenna and resistor on a silk film and apply these as a food sensor by monitoring the increasing resistance by the flow of gases from the spoiled food.

  17. Methanol Adsorption and Reaction on Samaria Thin Films on Pt(111

    Directory of Open Access Journals (Sweden)

    Jin-Hao Jhang

    2015-09-01

    Full Text Available We investigated the adsorption and reaction of methanol on continuous and discontinuous films of samarium oxide (SmOx grown on Pt(111 in ultrahigh vacuum. The methanol decomposition was studied by temperature programmed desorption (TPD and infrared reflection absorption spectroscopy (IRRAS, while structural changes of the oxide surface were monitored by low-energy electron diffraction (LEED. Methanol dehydrogenates to adsorbed methoxy species on both the continuous and discontinuous SmOx films, eventually leading to the desorption of CO and H2 which desorbs at temperatures in the range 400–600 K. Small quantities of CO2 are also detected mainly on as-prepared Sm2O3 thin films, but the production of CO2 is limited during repeated TPD runs. The discontinuous film exhibits the highest reactivity compared to the continuous film and the Pt(111 substrate. The reactivity of methanol on reduced and reoxidized films was also investigated, revealing how SmOx structures influence the chemical behavior. Over repeated TPD experiments, a SmOx structural/chemical equilibrium condition is found which can be approached either from oxidized or reduced films. We also observed hydrogen absence in TPD which indicates that hydrogen is stored either in SmOx films or as OH groups on the SmOx surfaces.

  18. Pseudomorphic growth of organic semiconductor thin films driven by incommensurate epitaxy

    International Nuclear Information System (INIS)

    Sassella, A.; Campione, M.; Raimondo, L.; Borghesi, A.; Bussetti, G.; Cirilli, S.; Violante, A.; Goletti, C.; Chiaradia, P.

    2009-01-01

    A stable pseudomorphic phase of α-quaterthiophene, a well known organic semiconductor, is obtained by growing films with organic molecular beam epitaxy (OMBE) on a single crystal of another organic semiconductor, namely, tetracene. The structural characteristics of the new phase are investigated by monitoring in situ the OMBE process by reflectance anisotropy spectroscopy; thus assessing that incommensurate epitaxy is in this case, the driving force for tuning the molecular packing in organic molecular films and in turn, their solid state properties

  19. Properties of Commercial PVC Films with Respect to Electron Dosimetry

    DEFF Research Database (Denmark)

    Miller, Arne; Liqing, Xie

    The properties of three commercially available polyvinyl chloride (PVC) film supplies and one made without additives were tested with respect to their application as routine dose monitors at electron accelerators. Dose fractionation was found to increase the response and the post-irradiation heat...

  20. Occupational radiation exposure in the GDR in 1978

    International Nuclear Information System (INIS)

    Poulheim, K.F.; Rothe, W.; Scheler, R.

    1980-01-01

    In 1978, radiation workers were monitored for external and internal radiation exposure on the basis of film badges (37,980 persons), measurements with a whole-body counter (186 persons) and analyses of biosamples (144 persons). According to the film badge data, the monthly over-exposures (more than 4 mGy) totalled 427. In 13 cases the monthly exposure exceeded 30 mGy, 8 persons received annual doses in the range of 50 to 120 mGy, and the highest annual dose was above 250 mGy. Also, annual collective and annual per caput doses have been given for the exposed population as a whole and some subgroups. Based on model considerations, the internal radiation exposure situation resulting from unintentional intakes of radionuclides has been assessed in terms of committed dose equivalents to members of two selected groups of radiation workers: (a) persons with more-than-average internal contamination levels; (b) persons subjected to frequent individual monitoring. Except for some organ doses, the individual internal radiation exposure was well below one-tenth the maximum permissible dose. (author)

  1. Characterization of tellurium-based films for NO2 detection

    International Nuclear Information System (INIS)

    Tsiulyanu, D.; Tsiulyanu, A.; Liess, H.-D.; Eisele, I.

    2005-01-01

    Sensing characteristics of tellurium-based thin films for NO 2 monitoring was studied systematically. The influence of contact materials, thermal treatment, temperature and thickness of the samples on the electrical conductivity and sensitivity to NO 2 with respect to scanning electron microscopy analyses is given. The possibility is shown to optimize the properties of the films for the development of a simple and stable NO 2 sensor device with rapid response/recovery time and low operating temperature. The sensing mechanism is discussed for the direct interaction of gaseous species with lone-pair electrons of chalcogen atoms

  2. Apparatuses and methods of determining if a person operating equipment is experiencing an elevated cognitive load

    Science.gov (United States)

    Watkins, Michael L.; Keller, Paul Edwin; Amaya, Ivan A.

    2015-06-16

    A method of, and apparatus for, determining if a person operating equipment is experiencing an elevated cognitive load, wherein the person's use of a device at a first time is monitored so as to set a baseline signature. Then, at a later time, the person's use of the device is monitored to determine the person's performance at the second time, as represented by a performance signature. This performance signature can then be compared against the baseline signature to predict whether the person is experiencing an elevated cognitive load.

  3. Black Films and Film-Makers.

    Science.gov (United States)

    Patterson, Lindsay, Ed.

    The development of black films and the attitudes of the film industry toward black films and black actors are some of the topics examined in this anthology of essays. Section 1, "Nigger to Supernigger," contains such articles as "The Death of Rastus: Negroes in American Films" by Thomas R. Cripps and "Folk Values in a New Medium" by Alain Locke…

  4. Electrodeless electro-hydrodynamic gentle printing of personalized medicines

    Science.gov (United States)

    Khusid, Boris; Elele, Ezinwa; Shen, Yueyang

    2010-11-01

    Drop-on-demand (DOD) principle appears to be a particular promising approach for manufacturing personalized treatments carefully tailored to a patient's genetic background. The authors have recently developed a DOD method for gentle printing of personalized medicines. A fluid is infused into an electrically insulating nozzle to form a pendant drop. A sufficiently strong voltage pulse is applied to external electrodes to stretch the pendant drop until it touches an electrically insulating film and forms a liquid bridge. As the liquid bridge is intentionally formed in an unstable configuration, it breaks up, creating two drops, one on the film and the other hanging from the nozzle. To prove the validity and versatility of the method, experiments are conducted on fluids whose viscosity, conductivity, dielectric constant, and surface tension vary over a broad range, respectively: 1-1045 cP, 0.02-290 μS/cm, 9-78, and 41-72 dyn/cm. We present a scaling analysis that captures the essential physics of drop evolution and provides the critical design guidelines. The work was supported by NSF Engineering Research Center on Structured Organic Particulate Systems.

  5. Trends of personal dosimetry at atomic power plants

    International Nuclear Information System (INIS)

    Yamamura, Seini

    1998-01-01

    The individual dosimetry at the atomic power station is sorted for monthly dosimetry, daily dosimetry and special job dosimetry in high dose circumstance. Film badge (passive dosimeter) can measure gamma dose, beta dose and neutron dose respectively lower than about 0.1 mSv. While workers are in the radiation controlled area, they have to wear the dosimeters and the individual dose is accumulated for every one month. Recently the Silicon semiconductors detecting beta ray and neutron have been developed. With microcircuit technology and these new sensors, new multiple function dosimeter of the card size had been put to practical use. The result of dose measurement obtained by the electronic dosimeter is consistent well with the measurement of usual film badge and new dosimeter can determine the dose as low as 0.01 mSv. The result is stored in the non-volatile memory in the electronic personal dosimeter and held for more than one year without the power supply. The function to read data directly from the memory improves the reliability of the data protection. The realization of the unified radiation control system that uses the electronic personal dosimeter for monthly dosimetry is expected. (J.P.N.)

  6. The Radiation Protection Service in Asuncion

    International Nuclear Information System (INIS)

    Zaldivar de Basualdo, I.

    1979-01-01

    This report details the activities of radiation protection services concerning radioisotopes, personal monitoring and film dosimetry service. Historical, organizational and regulatory aspects are also covered. (author)

  7. Evaluation of effective energy for QA and QC: measurement of half-value layer using radiochromic film density

    International Nuclear Information System (INIS)

    Gotanda, R.; Takeda, Y.; Gotanda, T.; Oishi Hospital, Hiroshima; Tabuchi, A.; Kawasaki Hospital, Okayama; Yamamoto, K.; Osaka Cancer Prevention and Detection Centre, Osaka; Kuwano, T.; Osaka Medical Center for Cancer and Cardovascular Diseases, Osaka; Yatake, H.; Kaizuka City Hospital, Osaka; Katsuda, T.

    2009-01-01

    The effective energy of diagnostic x-rays is important for quality assurance (QA) and quality control (QC). However, the half-value layer (HVL), which is necessary to evaluate the effective energy, is not ubiquitously monitored because ionization-chamber dosimetry is time-consuming and complicated. To verify the applicability of GAFCHROMIC XR type R (GAF-R) film for HVL measurement as an alternative to monitoring with an ionization chamber, a single-strip method for measuring the HVL has been evaluated. Calibration curves of absorbed dose versus film density were generated using this single-strip method with GAF-R film, and the coefficient of determination (r2) of the straight-line approximation was evaluated. The HVLs (effective energies) estimated using the GAF-R film and an ionization chamber were compared. The coefficient of determination (r2) of the straight-line approximation obtained with the GAF-R film was more than 0.99. The effective energies (HVLs) evaluated using the GAF-R film and the ionization chamber were 43.25 keV (5.10 m m) and 39.86 keV (4.45 mm), respectively. The difference in the effective energies determined by the two methods was thus 8.5%. These results suggest that GAF-R might be used to evaluate the effective energy from the film-density growth without the need for ionization-chamber measurements.

  8. Ion beams as a means of deposition and in-situ characterization of thin films and thin film layered structures

    International Nuclear Information System (INIS)

    Krauss, A.R.; Rangaswamy, M.; Gruen, D.M.; Lin, Y.P.; Schmidt, H.; Liu, Y.L.; Barr, T.; Chang, R.P.H.

    1992-01-01

    Ion beam-surface interactions produce many effects in thin film deposition which are similar to those encountered in plasma deposition processes. However, because of the lower pressures and higher directionality associated with the ion beam process, it is easier to avoid some sources of film contamination and to provide better control of ion energies and fluxes. Additional effects occur in the ion beam process because of the relatively small degree of thermalization resulting from gas phase collisions with both the ion beam and atoms sputtered from the target. These effects may be either beneficial or detrimental to the film properties, depending on the material and deposition conditions. Ion beam deposition is particularly suited to the deposition of multi-component films and layered structures, and can in principle be extended to a complete device fabrication process. However, complex phenomena occur in the deposition of many materials of high technical interest which make it desirable to monitor the film growth at the monolayer level. It is possible to make use of ion-surface interactions to provide a full suite of surface analytical capabilities in one instrument, and this data may be obtained at ambient pressures which are far too high for conventional surface analysis techniques. Such an instrument is under development and its current performance characteristics and anticipated capabilities are described

  9. Photo-induced thermoelectric response in suspended single-walled carbon nanotube films

    Science.gov (United States)

    St-Antoine, Benoit; Menard, David; Martel, Richard

    2010-03-01

    A study was carried out on the position dependent photovoltage of suspended single-walled carbon nanotube films in vacuum. The photoresponse of such films was found to be driven by a thermal mechanism, rather than by direct photoexcitation of carriers. [1] A model was developed which establishes a relation between the photoresponse profile and the local Seebeck coefficient of the film, thus opening up new perspectives for material characterization. The technique was demonstrated by monitoring the doping changes in the nanotube films obtained by successive current conditioning steps. Since the Seebeck coefficient of carbon nanotubes spans a considerable range depending on their doping state, the photovoltage amplitude can be tuned and large responses have been measured (up to 0.75mV for 1.2mW). [4pt] [1] B. St-Antoine et al. Nano Lett. 9, 3503 (2009)

  10. Thermoluminescent response of aluminium oxide thin films subject to gamma irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Arrieta, A.; Escobar A, L.; Camps, E.; Villagran, E.; Gonzalez, P.R

    2006-07-01

    The thermoluminescent (TL) properties of amorphous aluminium oxide thin films (thicknesses as low as 0.3 {mu}m) subjected to gamma (Co-60) irradiation are reported. Aluminium oxide thin films were prepared by laser ablation from an Al{sub 2}O{sub 3} target using a Nd: YAG laser with emission at the fundamental line. The films were exposed to gamma radiation (Co-60) in order to study their TL response. Thermoluminescence glow curves exhibited two peaks at 110 and 176 C. The high temperature peak shows good stability and 30% fading in the first 5 days after irradiation. A linear relationship between absorbed dose and the thermoluminescent response for doses span from 150 mGy to 100 Gy was observed. These results suggest that aluminium oxide thin films are suitable for detection and monitoring of gamma radiation. (Author)

  11. System And Method For Monitoring Traffic While Preserving Personal Privacy

    KAUST Repository

    Canepa, Edward

    2015-08-06

    A traffic monitoring system and method for mapping traffic speed and density while preserving privacy. The system can include fixed stations that make up a network and mobile probes that are associated with vehicles. The system and method do not gather, store, or transmit any unique or identifying information, and thereby preserves the privacy of members of traffic. The system and method provide real-time traffic density and speed mapping. The system and method can further be integrated with a complementary flood monitoring system and method.

  12. Oxygen ordering in Nb(1 1 0) films

    International Nuclear Information System (INIS)

    Hellwig, O.; Zabel, H.

    2003-01-01

    Synchrotron X-ray diffraction (XRD) during the atmospheric oxidation of epitaxial Nb(1 1 0) films at elevated temperature reveals the formation of highly ordered oxygen phases within the Nb lattice. The oxygen is stored on interstitial lattice sites without destroying the basic BCC structure of the Nb host lattice. However the lattice exhibits an out-of-plane lattice expansion of up to 4.3%. During oxidation we observe the formation of a non-ordered lattice gas phase succeeded by a well-defined sequence of oxygen superstructures until finally the whole film is consumed by the formation of amorphous Nb 2 O 5 . We show that XRD is an excellent tool to monitor the exact evolution of the different oxygen phases. In addition we demonstrate that UHV post-annealing of partially oxidized films can be used to rearrange the oxygen within the sample while keeping the overall amount of oxygen constant

  13. Assessment of toxic metals in waste personal computers

    International Nuclear Information System (INIS)

    Kolias, Konstantinos; Hahladakis, John N.; Gidarakos, Evangelos

    2014-01-01

    Highlights: • Waste personal computers were collected and dismantled in their main parts. • Motherboards, monitors and plastic housing were examined in their metal content. • Concentrations measured were compared to the RoHS Directive, 2002/95/EC. • Pb in motherboards and funnel glass of devices released <2006 was above the limit. • Waste personal computers need to be recycled and environmentally sound managed. - Abstract: Considering the enormous production of waste personal computers nowadays, it is obvious that the study of their composition is necessary in order to regulate their management and prevent any environmental contamination caused by their inappropriate disposal. This study aimed at determining the toxic metals content of motherboards (printed circuit boards), monitor glass and monitor plastic housing of two Cathode Ray Tube (CRT) monitors, three Liquid Crystal Display (LCD) monitors, one LCD touch screen monitor and six motherboards, all of which were discarded. In addition, concentrations of chromium (Cr), cadmium (Cd), lead (Pb) and mercury (Hg) were compared with the respective limits set by the RoHS 2002/95/EC Directive, that was recently renewed by the 2012/19/EU recast, in order to verify manufacturers’ compliance with the regulation. The research included disassembly, pulverization, digestion and chemical analyses of all the aforementioned devices. The toxic metals content of all samples was determined using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). The results demonstrated that concentrations of Pb in motherboards and funnel glass of devices with release dates before 2006, that is when the RoHS Directive came into force, exceeded the permissible limit. In general, except from Pb, higher metal concentrations were detected in motherboards in comparison with plastic housing and glass samples. Finally, the results of this work were encouraging, since concentrations of metals referred in the RoHS Directive were found in

  14. Assessment of toxic metals in waste personal computers

    Energy Technology Data Exchange (ETDEWEB)

    Kolias, Konstantinos; Hahladakis, John N., E-mail: john_chach@yahoo.gr; Gidarakos, Evangelos, E-mail: gidarako@mred.tuc.gr

    2014-08-15

    Highlights: • Waste personal computers were collected and dismantled in their main parts. • Motherboards, monitors and plastic housing were examined in their metal content. • Concentrations measured were compared to the RoHS Directive, 2002/95/EC. • Pb in motherboards and funnel glass of devices released <2006 was above the limit. • Waste personal computers need to be recycled and environmentally sound managed. - Abstract: Considering the enormous production of waste personal computers nowadays, it is obvious that the study of their composition is necessary in order to regulate their management and prevent any environmental contamination caused by their inappropriate disposal. This study aimed at determining the toxic metals content of motherboards (printed circuit boards), monitor glass and monitor plastic housing of two Cathode Ray Tube (CRT) monitors, three Liquid Crystal Display (LCD) monitors, one LCD touch screen monitor and six motherboards, all of which were discarded. In addition, concentrations of chromium (Cr), cadmium (Cd), lead (Pb) and mercury (Hg) were compared with the respective limits set by the RoHS 2002/95/EC Directive, that was recently renewed by the 2012/19/EU recast, in order to verify manufacturers’ compliance with the regulation. The research included disassembly, pulverization, digestion and chemical analyses of all the aforementioned devices. The toxic metals content of all samples was determined using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). The results demonstrated that concentrations of Pb in motherboards and funnel glass of devices with release dates before 2006, that is when the RoHS Directive came into force, exceeded the permissible limit. In general, except from Pb, higher metal concentrations were detected in motherboards in comparison with plastic housing and glass samples. Finally, the results of this work were encouraging, since concentrations of metals referred in the RoHS Directive were found in

  15. In situ monitoring of thermal crystallization of ultrathin tris(8-hydroxyquinoline) aluminum films using surface-enhanced Raman scattering.

    Science.gov (United States)

    Muraki, Naoki

    2014-01-01

    Thermal crystallization of 3, 10, and 60 nm-thick tris(8-hydroxyquinoline)aluminum (Alq3) films is studied using surface-enhanced Raman scattering with a constant heating rate. An abrupt higher frequency shift of the quinoline-stretching mode is found to be an indication of a phase transition of Alq3 molecules from amorphous to crystalline. While the 60 nm-thick film shows the same crystallization temperature as a bulk sample, the thinner films were found to have a lower crystallization temperature and slower rate of crystallization. Non-isothermal kinetics analysis is performed to quantify kinetic properties such as the Avrami exponent constants and crystallization rates of ultrathin Alq3 films.

  16. SU-E-T-665: Radiochromic Film Quenching Effect Reduction for Proton Beam Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Aldelaijan, S; Alzorkany, F; Moftah, B; Alrumayan, F [King Faisal Specialist Hospital & Research Centre, Riyadh (Saudi Arabia); Seuntjens, J [McGill University, Montreal, QC (Canada); Lewis, D [RCF Consulting, LLC, Monroe, CT (United States); Devic, S [McGill University, Montreal, QC (Canada); Jewish General Hospital, Montreal, QC (Canada)

    2015-06-15

    Purpose: Depending on the useful dose range in which radiochromic films operate, number of different radiochromic film models have been designed. The impact of different film models on quenching effect for percent depth dose (PDD) measurements in proton beams has been investigated. Methods: Calibrated PTW Markus ionization chamber was used to measure PDD and beam output for 26.5 MeV protons produced by CS30 cyclotron. An aluminum cylinder was added in front of the beam exit serving as a radiation shutter. The measured signal was normalized to a monitor chamber reading and subsequently scaled by ratio of water-to-air stopping powers at given depth, while the effective depth of measurements was scaled by ratios of material-to-water physical densities and CSDA ranges. Output was measured in water at 2.1 mm reference-depth in the plateau upstream from the Bragg peak. Following the TRS-398 reference dosimetry protocol for proton beams, the output was calibrated in water. Three radiochromic film models (EBT, EBT3 and HD-V2) were calibrated within Lexan phantom positioned at the same water-equivalent depth. Thicknesses of films sensitive layers were 34 µm, 30 µm and 8 µm, respectively. Small film pieces (1 x 2 cm{sup 2}) were positioned within polyethylene phantom along the beam central axis with an angulation of 5° for PDD measurements. Results: While the output of the proton beam was found to be around 7 Gy/sec, the actual value of the output per monitor chamber reading (2.32 Gy/nC) was used for reference-dose irradiations during film calibration. Dose ratios at the Bragg peak relative to the reference-depth were 3.88, 2.52, 2.19, and 2.02 for the Markus chamber, HD-V2, EBT3, and EBT film models, respectively. Conclusion: Results at hand suggest that quenching effect is reduced when a radiochromic film model with smaller sensitive layer thickness is used for PDD measurements in proton beams. David Lewis is the owner of RCF Consulting, LLC.

  17. Monitoring external beam radiotherapy using real-time beam visualization

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, Cesare H. [Department of Mechanical Engineering and Department of Radiation Oncology, Stanford University, Stanford, California 94305 (United States); Naczynski, Dominik J.; Yu, Shu-Jung S.; Xing, Lei, E-mail: lei@stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California 94305 (United States)

    2015-01-15

    Purpose: To characterize the performance of a novel radiation therapy monitoring technique that utilizes a flexible scintillating film, common optical detectors, and image processing algorithms for real-time beam visualization (RT-BV). Methods: Scintillating films were formed by mixing Gd{sub 2}O{sub 2}S:Tb (GOS) with silicone and casting the mixture at room temperature. The films were placed in the path of therapeutic beams generated by medical linear accelerators (LINAC). The emitted light was subsequently captured using a CMOS digital camera. Image processing algorithms were used to extract the intensity, shape, and location of the radiation field at various beam energies, dose rates, and collimator locations. The measurement results were compared with known collimator settings to validate the performance of the imaging system. Results: The RT-BV system achieved a sufficient contrast-to-noise ratio to enable real-time monitoring of the LINAC beam at 20 fps with normal ambient lighting in the LINAC room. The RT-BV system successfully identified collimator movements with sub-millimeter resolution. Conclusions: The RT-BV system is capable of localizing radiation therapy beams with sub-millimeter precision and tracking beam movement at video-rate exposure.

  18. Stoichiometry and superconductive properties of YBaCuO films deposited by spray pyrolysis

    International Nuclear Information System (INIS)

    Conde-Gallardo, A.; Falcony, C.; Ortiz, A.

    1994-01-01

    The dependence of the stoichiometry and the superconducting characteristics of YBaCuO films deposited by spray pyrolysis on the spraying solution composition and the deposition conditions is reported. It has been found that a proper optimization of the starting materials concentration in the spraying solution results in superconducting films with zero resistance temperature of 91 K and a transition to superconducting state within a 3 K range. X-ray diffraction and resistance vs temperature measurements have been used to monitor the crystal composition and the conductive characteristics of the films as a function of the spraying solution composition and the deposition parameters

  19. Organization of the individual monitoring in Brazil

    International Nuclear Information System (INIS)

    Cunha, P.

    1991-01-01

    There are about 35,000 workers monitored in Brazil. Most of them are employed onhealth and non-nuclear industrial areas. The external individual monitoring is done by 10 laboratories accredited by the Brazilian Nuclear Energy Commission, CNEN, applying specific regulation. The personal date and doses of the monitored workers are stored in a data bank. In this paper, future improvements are also discussed. (orig.)

  20. Acoustic monitoring of a fluidized bed coating process

    DEFF Research Database (Denmark)

    Naelapaa, Kaisa; Veski, Peep; Pedersen, Joan G.

    2007-01-01

      The aim of the study was to investigate the potential of acoustic monitoring of a production scale fluidized bed coating process. The correlation between sensor signals and the estimated amount of film applied and percentage release, respectively, were investigated in coating potassium chloride...

  1. Control method and system for use when growing thin-films on semiconductor-based materials

    Science.gov (United States)

    McKee, Rodney A.; Walker, Frederick J.

    2001-01-01

    A process and system for use during the growth of a thin film upon the surface of a substrate by exposing the substrate surface to vaporized material in a high vacuum (HV) facility involves the directing of an electron beam generally toward the surface of the substrate as the substrate is exposed to vaporized material so that electrons are diffracted from the substrate surface by the beam and the monitoring of the pattern of electrons diffracted from the substrate surface as vaporized material settles upon the substrate surface. When the monitored pattern achieves a condition indicative of the desired condition of the thin film being grown upon the substrate, the exposure of the substrate to the vaporized materials is shut off or otherwise adjusted. To facilitate the adjustment of the crystallographic orientation of the film relative to the electron beam, the system includes a mechanism for altering the orientation of the surface of the substrate relative to the electron beam.

  2. Preliminry results of the 1975 international personnel monitoring survey

    International Nuclear Information System (INIS)

    Becker, K.

    1975-11-01

    About 70 detailed questions have been answered in mid-1975 by 83 personnel monitoring services in 33 countries, representing almost half a million, or approximately 28 percent, of the world's total radiation workers, as well as by 11 customers of U. S. commercial services. Extensive data are given on many questions regarding the current system in use, future plans, and experiences, for example on the type(s) of TLD, film and readout instrumentation; monitoring period; applications for extremity and environmental monitoring; advantages and disadvantages of various systems; R and D projects; experience with beta and neutron dosimetry; intentional fake exposures; lower and upper dose limits; recordkeeping; and reporting of the results. The larger services in the advanced countries lead in the transition from film to TLD. More than half of the radiation workers already wear TLDs, or will do so within about two years. Important unsolved problems are fast neutron monitoring and the low information content and high initial cost of TLD. The trend is towards large, centralized, automatic services and recordkeeping, with extensive computer use for evaluation and data handling. There is a need for better performance standards and testing, and more information exchange and cooperation between services. (auth)

  3. Adsorption of lysozyme to phospholipid and meibomian lipid monolayer films.

    Science.gov (United States)

    Mudgil, Poonam; Torres, Margaux; Millar, Thomas J

    2006-03-15

    It is believed that a lipid layer forms the outer layer of the pre-ocular tear film and this layer helps maintain tear film stability by lowering its surface tension. Proteins of the aqueous layer of the tear film (beneath the lipid layer) may also contribute to reducing surface tension by adsorbing to, or penetrating the lipid layer. The purpose of this study was to compare the penetration of lysozyme, a tear protein, into films of meibomian lipids and phospholipids held at different surface pressures to determine if lysozyme were part of the surface layer of the tear film. Films of meibomian lipids or phospholipids were spread onto the surface of a buffered aqueous subphase. Films were compressed to particular pressures and lysozyme was injected into the subphase. Changes in surface pressure were monitored to determine adsorption or penetration of lysozyme into the surface film. Lysozyme penetrated a meibomian lipid film at all pressures tested (max=20 mN/m). It also penetrated phosphatidylglycerol, phosphatidylserine or phosphatidylethanolamine lipid films up to a pressure of 20 mN/m. It was not able to penetrate a phosphatidylcholine film at pressures >or=10 mN/m irrespective of the temperature being at 20 or 37 degrees C. However, it was able to penetrate it at very low pressures (<10 mN/m). Epifluorescence microscopy showed that the protein either adsorbs to or penetrates the lipid layer and the pattern of mixing depended upon the lipid at the surface. These results indicate that lysozyme is present at the surface of the tear film where it contributes to decreasing the surface tension by adsorbing and penetrating the meibomian lipids. Thus it helps to stabilize the tear film.

  4. Optical and impedance characteristics of passive films on pure aluminium

    International Nuclear Information System (INIS)

    Krishnakumar, R.; Szklarska-Smialowska, Z.

    1992-01-01

    Optical and Impedance behavior of pure bulk aluminum and pure sputtered aluminum film were studied in order to gain a better understanding of their fundamental passivation and pitting characteristics. Constant potential experiments at the passivation and pitting potentials, and potentiostatic anodic polarization were conducted while simultaneously monitoring the current, impedance and optical behavior, in-situ. Noise characteristics in the current data during the pit incubation period indicate that Cl - ions migrate with little impediment to the metal surface through defects in the passive film. Impedance experiments indicate that the polarization resistance fluctuates continuously with time during the pit incubation period, suggesting that impedance spectroscopy is sensitive to localized processes. The interfacial capacitance increases continuously during this time. The smallest pits observed on the sample surface (less than 10μ) are clearly crystallographic, indicating activation controlled dissolution at pits. The film capacitance increases with exposure time at the passivation potential, while the polarization resistance decreases continuously. The decrease in the film resistance is thought to be due to chloride incorporation at defects in the passive film. The increase in film capacitance at the passivation and pitting potential is due to an increase in the film dielectric constant caused by either a compositional change or anion incorporation. Ellipsometry results indicate growth of a dual layered film on the pure aluminum surface, with the outer layer probably containing varying amounts of incorporated chloride depending on the applied potential. Preliminary experiments indicate that in the case of sputtered aluminum film, the passive film resistance is at least an order of magnitude higher than that of bulk aluminum. This is due to the fine grain structure of sputtered Al and hence a more defect free passive film than that formed on bulk aluminum. There is

  5. Disposable urea biosensor based on nanoporous ZnO film fabricated from omissible polymeric substrate

    International Nuclear Information System (INIS)

    Rahmanian, Reza; Mozaffari, Sayed Ahmad; Abedi, Mohammad

    2015-01-01

    In the present study, a facile and simple fabrication method of a semiconductor based urea biosensor was reported via three steps: (i) producing a ZnO–PVA composite film by means of a polymer assisted electrodeposition of zinc oxide (ZnO) on the F-doped SnO 2 conducting glass (FTO) using water soluble polyvinyl alcohol (PVA), (ii) obtaining a nanoporous ZnO film by PVA omission via a subsequent post-treatment by annealing of the ZnO–PVA film, and (iii) preparation of a FTO/ZnO/Urs biosensor by exploiting a nanoporous ZnO film as an efficient and excellent platform area for electrostatic immobilization of urease enzyme (Urs) which was forced by the difference in their isoelectric point (IEP). The characterization techniques focused on the analysis of the ZnO–PVA film surfaces before and after annealing, which had a prominent effect on the porosity of the prepared ZnO film. The surface characterization of the nanostructured ZnO film by a field emission-scanning electron microscopy (FE–SEM), exhibited a film surface area as an effective bio-sensing matrix for enzyme immobilization. The structural characterization and monitoring of the biosensor fabrication was performed using UV–Vis, Fourier Transform Infrared (FT-IR), Raman Spectroscopy, Thermogravimetric Analysis (TGA), Cyclic Voltammetry (CV), and Electrochemical Impedance Spectroscopy (EIS) techniques. The impedimetric results of the FTO/ZnO/Urs biosensor showed a high sensitivity for urea detection within 8.0–110.0 mg dL −1 with the limit of detection as 5.0 mg dL −1 . - Highlights: • Novel disposable impedimetric urea biosensor fabrication based on ZnO–nanoporous transducer • Exploiting omissible PVA polymer as a simple strategy for ZnO–nanoporous film preparation • ZnO–nanoporous film as a good pore framework with large surface area/volume for enzyme immobilization • Application of impedimetric measurement for urea monitoring due to its rapidity, sensitivity, and repeatability

  6. Disposable urea biosensor based on nanoporous ZnO film fabricated from omissible polymeric substrate

    Energy Technology Data Exchange (ETDEWEB)

    Rahmanian, Reza; Mozaffari, Sayed Ahmad, E-mail: mozaffari@irost.ir; Abedi, Mohammad

    2015-12-01

    In the present study, a facile and simple fabrication method of a semiconductor based urea biosensor was reported via three steps: (i) producing a ZnO–PVA composite film by means of a polymer assisted electrodeposition of zinc oxide (ZnO) on the F-doped SnO{sub 2} conducting glass (FTO) using water soluble polyvinyl alcohol (PVA), (ii) obtaining a nanoporous ZnO film by PVA omission via a subsequent post-treatment by annealing of the ZnO–PVA film, and (iii) preparation of a FTO/ZnO/Urs biosensor by exploiting a nanoporous ZnO film as an efficient and excellent platform area for electrostatic immobilization of urease enzyme (Urs) which was forced by the difference in their isoelectric point (IEP). The characterization techniques focused on the analysis of the ZnO–PVA film surfaces before and after annealing, which had a prominent effect on the porosity of the prepared ZnO film. The surface characterization of the nanostructured ZnO film by a field emission-scanning electron microscopy (FE–SEM), exhibited a film surface area as an effective bio-sensing matrix for enzyme immobilization. The structural characterization and monitoring of the biosensor fabrication was performed using UV–Vis, Fourier Transform Infrared (FT-IR), Raman Spectroscopy, Thermogravimetric Analysis (TGA), Cyclic Voltammetry (CV), and Electrochemical Impedance Spectroscopy (EIS) techniques. The impedimetric results of the FTO/ZnO/Urs biosensor showed a high sensitivity for urea detection within 8.0–110.0 mg dL{sup −1} with the limit of detection as 5.0 mg dL{sup −1}. - Highlights: • Novel disposable impedimetric urea biosensor fabrication based on ZnO–nanoporous transducer • Exploiting omissible PVA polymer as a simple strategy for ZnO–nanoporous film preparation • ZnO–nanoporous film as a good pore framework with large surface area/volume for enzyme immobilization • Application of impedimetric measurement for urea monitoring due to its rapidity, sensitivity, and

  7. Maintenance experiences with hand and foot monitor for monitoring alpha and beta radiation of personnel in NFC

    International Nuclear Information System (INIS)

    Ramachandra Rao, A.; Kulkarni, R.S.; Banerjee, P.K.

    2010-01-01

    NFC is producing natural uranium and enriched uranium fuels for various reactors including PHWR etc. Monitoring of α and β radiations in the active plants of NFC is very much essential in many aspects. The personnel who are handling radiation materials have to be monitored for α radiation of hands and cloths and β radiation of feet. So the Alpha and Beta Monitor became important monitoring equipment for monitoring α and β radiations of persons working in active plants of NFC. Many Alpha and Beta Monitors of make, ECIL, PLA, and Nucleonix etc. were being used in active plants in NFC. Basically α and β radiation monitors consists of four PMT (Photo Multiplier Tubes) for detection of radiation of hands and one PMT for monitoring clothes. The PMT use ZnS (Ag) as the scintillator for detection of α radiation. GM tubes are used to detect β radiation of feet. The latest Hand and Foot Monitors have been incorporated with PC based monitoring system along with software for making the monitoring process more efficient and user friendly. As an instrumentation maintenance team for these monitors, our experiences are varied. These monitors are to be periodically maintained and tested for its effective functioning in monitoring the nuclear radiation. The monitors procured from M/s. ECIL were being used since long time in these areas. The instrumentation maintenance had faced some problems with these monitors such as frequent failure of High Voltage cards, Amplifier and Counter PCB cards. Modifications were made in the circuits of High Voltage and Counter cards to minimize the failure rate and for loading of Display and Monitoring Software through Hard disk instead of from floppy disk. So the availability of monitors for monitoring radiation got improved. Later the introduction of more sophisticated α and β radiation monitors of M/s. PLA make in these areas further improved monitoring of radiation of personnel working in active areas. These monitors are more user

  8. Transition in occupational radiation exposure monitoring methods in diagnostic and interventional radiology

    International Nuclear Information System (INIS)

    Loennroth, N.; Hirvonen-Kari, M.; Timonen, M.; Savolainen, S.; Kortesniemi, M.

    2008-01-01

    Radiation exposure monitoring is a traditional keystone of occupational radiation safety measures in medical imaging. The aim of this study was to review the data on occupational exposures in a large central university hospital radiology organisation and propose changes in the radiation worker categories and methods of exposure monitoring. An additional objective was to evaluate the development of electronic personal dosimeters and their potential in the digitised radiology environment. The personal equivalent dose of 267 radiation workers (116 radiologists and 151 radiographers) was monitored using personal dosimeters during the years 2006-2010. Accumulated exposure monitoring results exceeding the registration threshold were observed in the personal dosimeters of 73 workers (59 radiologists' doses ranged from 0.1 to 45.1 mSv; 14 radiographers' doses ranged from 0.1 to 1.3 mSv). The accumulated personal equivalent doses are generally very small, only a few angiography radiologists have doses >10 mSv per 5 y. The typical effective doses are -1 and the highest value was 0.3 mSv (single interventional radiologist). A revised categorisation of radiation workers based on the working profile of the radiologist and observed accumulated doses is justified. Occupational monitoring can be implemented mostly with group dosimeters. An active real-time dosimetry system is warranted to support radiation protection strategy where optimisation aspects, including improving working methods, are essential. (authors)

  9. Comparison of residual stress measurement in thin films using surface micromachining method

    International Nuclear Information System (INIS)

    He, Q.; Luo, Z.X.; Chen, X.Y.

    2008-01-01

    Conductive, dielectric, semiconducting, piezoelectric and ferroelectric thin films are extensively used for MEMS/NEMS applications. One of the important parameters of thin films is residual stress. The residual stress can seriously affect the properties, performance and long-term stability of the films. Excessive compressive or tensile stress results in buckling, cracking, splintering and sticking problems. Stress measurement techniques are therefore essential for both process development and process monitoring. Many suggestions for stress measurement in thin films have been made over the past several decades. This paper is concentrated on the in situ stress measurement using surface micromachining techniques to determine the residual stress. The authors review and compare several types of stress measurement methods including buckling technique, rotating technique, micro strain gauge and long-short beam strain sensor

  10. Human biological monitoring of occupational genotoxic exposures

    DEFF Research Database (Denmark)

    Knudsen, Lisbeth E.; Sorsa, M

    1993-01-01

    Human biological monitoring is a valuable tool for exposure assessment in groups of persons occupationally exposed to genotoxic agents. If the monitoring activity covers genetic material the term genetic monitoring is used. The methods used for genetic monitoring are either substance specific, e......) occupational exposure limit value of styrene in ambient air. The consideration of ethical issues in human genetic monitoring is an important but often overlooked aspect. This includes the scientific and preventional relevance of performing a test on individuals, pre- and post study information of donors...

  11. Surface enhanced Raman scattering as an in-reactor monitor of phenomena of interest to the Nuclear Power Industry

    International Nuclear Information System (INIS)

    Devine, T.M.

    1994-01-01

    Surface enhanced Raman spectroscopy (SERS) is proposed as a technique for monitoring in situ the passive films and corrosion products that form on the surfaces of alloys of interest in nuclear power plants. The technique is a highly sensitive procedure for detecting even very small quantities of species present on surfaces, in particular the surface of metallic alloys. The data could, for example, identify the constituents in passive films that are less than a monolayer in average thickness. Processes such as 60 Co pick-up could be monitored in real time. In fact, if it is known that incorporation of 60 Co occurs when a particular oxide film forms on the surface of the alloy, then measurement of the SER spectra could indicate when such films are beginning to form and thereby provide an early indication that conditions inside the reactor are now suitable for 60 Co pick-up in the passive films

  12. Synthesis and film formation of furfuryl- and maleimido carbonic acid derivatives of dextran.

    Science.gov (United States)

    Elschner, Thomas; Obst, Franziska; Stana-Kleinschek, Karin; Kargl, Rupert; Heinze, Thomas

    2017-04-01

    Carbonic acid derivatives of dextran possessing furfuryl- and maleimido moieties were synthesized and processed into thin films by spin coating. First, products with different degrees of substitution (DS) of up to 3.0 and substitution patterns were obtained and characterized by NMR- and FTIR spectroscopy, as well as elemental analysis. Thin films possessing maleimide groups were obtained by spin coating of maleimido dextran (furan-protected) and dextran furfuryl carbamate that was converted with bismaleimide. The removal of the protecting group (furan) on the thin film was monitored by QCM-D and compared with gravimetric analysis of the bulk material. Film morphology and wettability were determined by means of AFM and contact angle measurements. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Sprayed films of europium complexes toward light conversion devices

    Energy Technology Data Exchange (ETDEWEB)

    Camacho, Sabrina A.; Aoki, Pedro H.B.; Constantino, Carlos J.L.; Pires, Ana Maria, E-mail: anapires@fct.unesp.br

    2014-09-15

    Rare-earth complexes have become subject of intensive research due to the high quantum efficiency of their emission, very narrow bands, and excellent fluorescence monochromaticity. The chemical design and characterization of Eu complexes based on β-diketone ligands hexafluoroacetylacetate (hfac) and dibenzoylmetanate (dbm) is reported here. K[Eu(dbm){sub 4}] and K[Eu(hfac){sub 4}] complexes were immobilized as thin films by using the spray technique, a promising methodology for practical applications. The latter provides not only a faster layer deposition but also larger coated areas compared to conventional methods, such as layer-by-layer (LbL) and Langmuir–Blodgett (LB). The growth of the sprayed films was monitored through microbalance (QCM) and ultraviolet–visible (UV–Vis) absorption spectroscopy, which reveal a higher mass and absorbance per deposited layer of K[Eu(dbm){sub 4}] film. Micro-Raman images display a more homogeneous spatial distribution of the K[Eu(dbm){sub 4}] complex throughout the film, when compared to K[Eu(hfac){sub 4}] film. At nanometer scale, atomic force microscopy (AFM) images indicate that the roughness of the K[Eu(hfac){sub 4}] film is approximately one order of magnitude higher than that for the K[Eu(dbm){sub 4}] film, which pattern is kept at micrometer scale according to micro-Raman measurements. The photoluminescence data show that the complexes remain as pure red emitters upon spray immobilization. Besides, the quantum efficiency for the sprayed films are found equivalent to the values achieved for the powders, highlighting the potential of the films for application in light conversion devices. - Highlights: • Rare earth complexes thin films based on β-diketone ligands. • Spraying procedures to fabricate layer-by-layer (LbL) luminescent thin films. • Chemical design of Eu complexes based on hfac and dbm β-diketones ligands immobilized as sprayed films. • Pure red emitters upon spray immobilization. • Sprayed

  14. Study of neural cells on organic semiconductor ultra thin films

    Energy Technology Data Exchange (ETDEWEB)

    Bystrenova, Eva; Tonazzini, Ilaria; Stoliar, Pablo; Greco, Pierpaolo; Lazar, Adina; Dutta, Soumya; Dionigi, Chiara; Cacace, Marcello; Biscarini, Fabio [ISMN-CNR, Bologna (Italy); Jelitai, Marta; Madarasz, Emilia [IEM- HAS, Budapest (Hungary); Huth, Martin; Nickel, Bert [LMU, Munich (Germany); Martini, Claudia [Dept. PNPB, Univ. of Pisa (Italy)

    2008-07-01

    Many technological advances are currently being developed for nano-fabrication, offering the ability to create and control patterns of soft materials. We report the deposition of cells on organic semiconductor ultra-thin films. This is a first step towards the development of active bio/non bio systems for electrical transduction. Thin films of pentacene, whose thickness was systematically varied, were grown by high vacuum sublimation. We report adhesion, growth, and differentiation of human astroglial cells and mouse neural stem cells on an organic semiconductor. Viability of astroglial cells in time was measured as a function of the roughness and the characteristic morphology of ultra thin organic film, as well as the features of the patterned molecules. Optical fluorescence microscope coupled to atomic force microscope was used to monitor the presence, density and shape of deposited cells. Neural stem cells remain viable, differentiate by retinoic acid and form dense neuronal networks. We have shown the possibility to integrate living neural cells on organic semiconductor thin films.

  15. Film beyond boundaries: film, migrant narratives and other media Film beyond boundaries: film, migrant narratives and other media

    Directory of Open Access Journals (Sweden)

    Anelise Reich Corseuil

    2008-04-01

    (1964, or Os Fuzis (1964. Xavier points out the differences in the representation of violence in contemporary films as it incorporates and projects new forms of violence more associated with an urban and capitalist environment in which self-interest, the powerlessness of the State, and the cangaceiro's distancing from his collectivity devoid violence from a sense of justice and justified revenge. Xavier's article contextualizes the changing forms of representation of violence in Brazilian cinema—changes that, despite their specificities, map out an ironic perception of the lack of a collective national project, but which are still inserted in a market economy that is quite tuned in to the demands of national and international audiences. The importance of representation for one's understanding of the interrelations between a national and an international film industry is also discussed in José Gatti's essay “Carmen Miranda's White Dress: Ethnicity, Syncretism and Subaltern Sexualities in Springtime in the Rockies”. Gatti discusses the sophisticated role played by Carmen Miranda as an icon in contemporary cultural industry, whose influence went far beyond her alleged performance as a “Brazilian cultural ambassador in the United States” (92. Gatti argues that in spite of all critiques of Carmen Miranda's alleged manipulation by the Hollywood industry, she was the “auteur of her own persona”, as a sort of “multiauthor” capable of adapting her own needs and personal/political projects to the agenda imposed by the film industry. This sense of malleability, flexibility, and adaptation allowed Carmen Miranda to negotiate her position within the film industry. Furthermore, such intricacies in the relationship established between the star and the industry create a space for a more sophisticated analysis of the interrelations between national culture and the international industry. In “Techno-Euphoria and the World-Improving Dream”, Robert Burgoyne

  16. The last Glauber: notes about travel, photography and memory in Diário de Sintra film

    Directory of Open Access Journals (Sweden)

    Elane Abreu

    2012-12-01

    Full Text Available How to differ the traveller from the exiled person? How to think the memory created in exile? These are the axes by which we turn Diário de Sintra film (2008, by Paula Gaitán, around. The film is a poetic account of Glauber Rocha's exile at this city, where photographs serve as mnemonic guide for the search of moviemaker's passage vestiges by Sintra. The film consists in an exercise of living in frontier, formation place of a fragmented, unfinished and precarious memory.

  17. Polycaprolactone Thin-Film Micro- and Nanoporous Cell-Encapsulation Devices.

    Science.gov (United States)

    Nyitray, Crystal E; Chang, Ryan; Faleo, Gaetano; Lance, Kevin D; Bernards, Daniel A; Tang, Qizhi; Desai, Tejal A

    2015-06-23

    Cell-encapsulating devices can play an important role in advancing the types of tissue available for transplantation and further improving transplant success rates. To have an effective device, encapsulated cells must remain viable, respond to external stimulus, and be protected from immune responses, and the device itself must elicit a minimal foreign body response. To address these challenges, we developed a micro- and a nanoporous thin-film cell encapsulation device from polycaprolactone (PCL), a material previously used in FDA-approved biomedical devices. The thin-film device construct allows long-term bioluminescent transfer imaging, which can be used for monitoring cell viability and device tracking. The ability to tune the microporous and nanoporous membrane allows selective protection from immune cell invasion and cytokine-mediated cell death in vitro, all while maintaining typical cell function, as demonstrated by encapsulated cells' insulin production in response to glucose stimulation. To demonstrate the ability to track, visualize, and monitor the viability of cells encapsulated in implanted thin-film devices, we encapsulated and implanted luciferase-positive MIN6 cells in allogeneic mouse models for up to 90 days. Lack of foreign body response in combination with rapid neovascularization around the device shows promise in using this technology for cell encapsulation. These devices can help elucidate the metrics required for cell encapsulation success and direct future immune-isolation therapies.

  18. Safeguards equipment of the future: Integrated monitoring systems and remote monitoring

    International Nuclear Information System (INIS)

    Sonnier, C.S.; Johnson, C.S.

    1994-01-01

    From the beginning, equipment to support IAEA Safeguards could be characterized as that which is used to measure nuclear material, Destructive Assay (DA) and Non Destructive Assay (NDA), and that which is used to provide continuity of knowledge between inspection intervals, Containment ampersand Surveillance (C/S). C/S equipment has often been thought of as Cameras and Seals, with a limited number of monitors being employed as they became available. In recent years, technology has advanced at an extremely rapid rate, and continues to do so. The traditional film cameras are being replaced by video equipment, and fiber optic and electronic seals have come into rather widespread use. Perhaps the most interesting aspect of this evolution, and that which indicates the wave of the future without much question, is the integration of video surveillance and electronic seals with a variety of monitors. This is demonstrated by safeguards systems which are installed in several nuclear facilities in France, Germany, Japan, the UK, the USA, and elsewhere. The terminology of Integrated Monitoring Systems (IMS) has emerged, with the employment of network technology capable of interconnecting all desired elements in a very flexible manner. Also, the technology for transmission of a wide variety of information to off-site locations, termed Remote Monitoring, is in widespread industrial use, requiring very little adaptation for safeguards use. This paper examines the future of the Integrated Monitoring Systems and Remote Monitoring in International Safeguards, including technical and other related factors

  19. Personal exposure control using TLD

    International Nuclear Information System (INIS)

    Ishiguro, Hideharu; Takeda, Shinso

    1979-01-01

    In the Tokai Works of the Power Reactor and Nuclear Fuel Development Corporation (PNC), for personal exposure control, the switching from film badges to TLD badges (and also finger-ring type local dosimeters) was made in fiscal 1974. The facilities involved are a fuel reprocessing plant, a PuO 2 -UO 2 mixed fuel production facility, and a centrifugal uranium enrichment development facility. The types of radiation concerned are various, such as γ(x), β and n. The situation of personal exposure control with TLD and the dose evaluation methods for respective radiations are explained. The number of personnel subject to exposure control, including transient people, is about 2500 - 3000 per three months. The TLD badges used are a special PNC type with TLDs to measure separately γ(x), β and n. With casings made of ABS resin, the external dimensions are 76 mm x 46 mm. (J.P.N.)

  20. A Urea Biosensor from Stacked Sol-Gel Films with Immobilized Nile Blue Chromoionophore and Urease Enzyme

    OpenAIRE

    Alqasaimeh, Muawia Salameh; Heng, Lee Yook; Ahmad, Musa

    2007-01-01

    An optical urea biosensor was fabricated by stacking several layers of sol-gel films. The stacking of the sol-gel films allowed the immobilization of a Nile Blue chromoionophore (ETH 5294) and urease enzyme separately without the need of any chemical attachment procedure. The absorbance response of the biosensor was monitored at 550 nm, i.e. the deprotonation of the chromoionophore. This multi-layer sol-gel film format enabled higher enzyme loading in the biosensor to be achieved. The urea op...

  1. Electrical resistivity of CuAlMo thin films grown at room temperature by dc magnetron sputtering

    OpenAIRE

    Birkett, Martin; Penlington, Roger

    2016-01-01

    We report on the thickness dependence of electrical resistivity of CuAlMo films grown by dc magnetron sputtering on glass substrates at room temperature. The electrical resistance of the films was monitored in situ during their growth in the thickness range 10–1000 nm. By theoretically modelling the evolution of resistivity during growth we were able to gain an insight into the dominant electrical conduction mechanisms with increasing film thickness. For thicknesses in the range 10–25 nm the ...

  2. Personal exposures of preschool children to carbon monoxide and nitrogen dioxide. The role of gas stoves

    Energy Technology Data Exchange (ETDEWEB)

    Alm, S.; Jantunen, M.J.; Mukala, K.; Tuomisto, J. [National Public Health Institute, Kuopio (Finland). Div. of Environmental Health; Pasanen, P. [Kuopio Univ. (Finland)

    1993-12-31

    Personal 1-h mean CO exposures of preschool children in two day care centers of Helsinki were measured with continuously recording personal exposure monitors, and their personal 1-wk NO{sub 2} exposures with Palmes tubes. The results were compared to fixed site ambient air monitoring results and related to the presence of high CO, low heat value town gas fired stoves in the homes of the children. Results show that fixed site ambient air monitors are of little value in predicting personal exposures of children or even their relative differences between areas, and also that town gas fired stoves have a profound effect on the CO exposures, and little or no effect on the NO{sub 2} exposures of the children. (author)

  3. Composite Ag/C:H:N films prepared by planar magnetron deposition

    Energy Technology Data Exchange (ETDEWEB)

    Hlidek, P. [Charles University, Faculty of Mathematics and Physics, Praha (Czech Republic)], E-mail: hlidek@karlov.mff.cuni.cz; Hanus, J.; Biederman, H.; Slavinska, D.; Pesicka, J. [Charles University, Faculty of Mathematics and Physics, Praha (Czech Republic)

    2008-05-30

    Composite Ag/C:H:N films were deposited by means of an unbalanced magnetron operated in a gas mixture of nitrogen and n-hexane. Composition of the films was controlled by electric power delivered to the magnetron and by ratio of nitrogen and n-hexane in the working gas mixture. The films were characterized using transmission electron microscopy, by the absorption spectra in visible and near infrared regions and by Fourier transform infrared spectroscopy. Immediately after film deposition and without breaking vacuum (in situ) corresponding vibration infrared spectra were scanned and their evolution during ageing of the films was monitored. Wettability as determined from water contact angle was improved with raising nitrogen contents, i.e. with increasing the electric power and the ratio of nitrogen/n-hexane in the working gas mixture. The increased wettability is likely caused by presence of NH{sub x} groups in Ag/C:H:N films. The incorporation of nitrogen effectively prevents the formation of carboxylate groups on the silver inclusions surfaces during the aging in the open air. In addition, the oxidation mechanism of the polymer matrix is modified.

  4. “Fremd bin ich eingezogen… ” − An Outsider’s Vision of Ireland in Urszula Antoniak’s Nothing Personal

    Directory of Open Access Journals (Sweden)

    Katharina Schmid

    2013-03-01

    Full Text Available The following essay analyses Urszula Antoniak’s film Nothing Personal with a view to determining how the Irish-Dutch co-production engages with previously defined ways of understanding Ireland. The film acknowledges the long tradition of representing the country as modernity’s other by drawing strongly on romantic myths about Ireland. At the same time, however, it subtly undermines the authenticity of the vision it presents and foregrounds the projections which are at work in its construction. As the film alludes to and eventually disrupts generic conventions, the foreign can be seen to explode any simplistic formula and elude the grasp of myth. Ultimately, Nothing Personal aims to situate the othering of Ireland in a wider context and to draw attention to a recurring pattern in European approaches to foreignness.

  5. Film quality in film mammography. Pt. 2

    International Nuclear Information System (INIS)

    Friedrich, M.; Weskamp, P.; Freie Univ. Berlin

    1976-01-01

    During consideration of three film mammographic systems, the concept of signal/noise ratio is developed as a quantitative measure of film quality. The ability to recognise detail related to detail size, film blackening and exposure geometry was studied for various systems, and the quality profiles are discussed. There is a considerable difference in quality between industrial films without screens and film-screen combinations; however, exposure geometry during mammography has a considerable effect which tends to reduce the difference. Consequently, detail sizes of 200 μ to 1,000 μ (including the majority of mammographic micro-calcifications) are shown about equally well. Contrast for the lo-dose system is somewhat less than for adequately exposed industrial film. Over-exposure with the lo-dose system, contrary to industrial film, rapidly leads to unsatisfactory results. On the other hand it is often not possible to obtain an adequate exposure when using industrial film. For these reasons it is often an advantage to examine large breasts and the dense breasts of young women with a film-screen combination which requires approximately one eighth of the dose necessary for industrial film. For small or easily compressable breasts best results are obtained, using an adequate exposure by employing industril film; radiation dose it then acceptable. (orig./ORU) [de

  6. Nanostructured thin films of indium oxide nanocrystals confined in alumina matrixes

    International Nuclear Information System (INIS)

    Bouifoulen, A.; Edely, M.; Errien, N.; Kassiba, A.; Outzourhit, A.; Makowska-Janusik, M.; Gautier, N.; Lajaunie, L.; Oueriagli, A.

    2011-01-01

    Nanocrystals of indium oxide (In 2 O 3 ) with sizes below 10 nm were prepared in alumina matrixes by using a co-pulverization method. The used substrates such as borosilicate glasses or (100) silicon as well as the substrate temperatures during the deposition process were modified and their effects characterized on the structural and physical properties of alumina-In 2 O 3 films. Complementary investigation methods including X-ray diffraction, optical transmittance in the range 250-1100 nm and transmission electron microscopy were used to analyze the nanostructured films. The crystalline order, morphology and optical responses were monitored as function of the deposition parameters and the post-synthesis annealing. The optimal conditions were found and allow realizing suitable nanostructured films with a major crystalline order of cubic phase for the In 2 O 3 nanocrystals. The optical properties of the films were analyzed and the key parameters such as direct and indirect band gaps were evaluated as function of the synthesis conditions and the crystalline quality of the films.

  7. Laser-Induced, Local Oxidation of Copper Nanoparticle Films During Raman Measurements

    Science.gov (United States)

    Hight Walker, Angela R.; Cheng, Guangjun; Calizo, Irene

    2011-03-01

    The optical properties of gold and silver nanoparticles and their films have been thoroughly investigated as surface enhanced Raman scattering (SERS) substrates and chemical reaction promoters. Similar to gold and silver nanoparticles, copper nanoparticles exhibit distinct plasmon absorptions in the visible region. The work on copper nanoparticles and their films is limited due to their oxidization in air. However, their high reactivity actually provides an opportunity to exploit the laser-induced thermal effect and chemical reactions of these nanoparticles. Here, we present our investigation of the local oxidation of a copper nanoparticle film induced by a visible laser source during Raman spectroscopic measurements. The copper nanoparticle film is prepared by drop-casting chemically synthesized copper colloid onto silicon oxide/silicon substrate. The local oxidation induced by visible lasers in Raman spectroscopy is monitored with the distinct scattering peaks for copper oxides. Optical microscopy and scanning electron microscopy have been used to characterize the laser-induced morphological changes in the film. The results of this oxidation process with different excitation wavelengths and different laser powers will be presented.

  8. Monitoring system for gamma radiation of porch type for vehicles

    International Nuclear Information System (INIS)

    Vazquez C, R.M.; Molina, G.; Gutierrez O, E.; Ramirez J, F.J.; Garcia H, J.M.; Aguilar B, M.A.; Vilchis P, A.E.; Cruz E, P.; Torres B, M.A.

    2005-01-01

    A monitoring system of gamma radiation for vehicles of the porch type developed in the ININ is presented. This system carries out the radiological monitoring of the vehicles in continuous form, detecting the bottom radiological environment and the presence of nuclear material transported in vehicles. The vehicles are monitored while they pass to low speed through the porch. The detectors are plastic scintillators of great volume that allow high sensibility detection. The arrangement of detecting is interconnected in net, and the data are concentrated on a personal computer whose interface man-machine can be accessed from any personal computer connected to Internet. The system monitoring in real time with options of sampling times from 50 ms configurable up to 500 ms. (Author)

  9. An on-line tritium-in-water monitor

    International Nuclear Information System (INIS)

    Singh, A.N.; Ratnakaran, M.; Vohra, K.G.

    1985-01-01

    The paper describes the development and operation of a continuous on-line tritium-in-water monitor for the detection of heavy water leaks into the secondary coolant light water of a heavy water power reactor. The heart of the instrument is its plastic scintillator sponge detector, made from 5 μm thick plastic scintillator films. The sponge weighs only about 1 g and is in the form of disc of 48 mm diameter and 8 mm thickness. The total surface area of the films is about 3000 cm 2 . In the coincidence mode of counting, the detector gives 1000 cps for the passage of 3.7 x 10 4 Bq/cm 3 (1 μCi/cm 3 ) of tritiated water. The background in 6 cm thick lead shielding in the laboratory is 0.2 cps, and inside the reactor building it is below 1 cps. The monitor presently scans 18 sample lines in sequence for 5 min each and gives a printout for the activity in each line. (orig.)

  10. An on-line tritium-in-water monitor

    Science.gov (United States)

    Singh, A. N.; Ratnakaran, M.; Vohra, K. G.

    1985-05-01

    The paper describes the development and operation of a continuous on-line tritium-in-water monitor for the detection of heavy water leaks into the secondary coolant light water of a heavy water power reactor. The heart of the instrument is its plastic scintillator sponge detector, made from 5 μm thick plastic scintillator films. The sponge weighs only about 1 g and is in the form of disc of 48 mm diameter and 8 mm thickness. The total surface area of the films is about 3000 cm 2. In the coincidence mode of counting, the detector gives 1000 cps for the passage of 3.7 × 10 4 Bq/cm 3 (1 μCi/cm 3) of tritiated water. The background in 6 cm thick lead shielding in the laboratory is 0.2 cps, and inside the reactor building it is below 1 cps. The monitor presently scans 18 sample lines in sequence for 5 min each and gives a printout for the activity in each line.

  11. The impact of exposure to films of natural and built environments on state body appreciation.

    Science.gov (United States)

    Swami, Viren; Pickering, Mark; Barron, David; Patel, Shreepali

    2018-06-12

    Previous work has shown that exposure to images of nature results in elevated state body appreciation, but static images may lack ecological validity. Here, we examined the impact of exposure to short films of simulated, first-person walks in natural or built environments. Thirty-six university students completed a measure of state body appreciation before and after watching films of either a walk in a natural or a built environment created specifically for the present study. Two weeks later, they completed the same task but watched the other film type. Results indicated that exposure to the film of a natural environment resulted in significantly elevated state body appreciation (d = 0.66). There was no significant change in state body appreciation following exposure to the film of the built environment (d = 0.14). These findings suggest that exposure to films depicting the natural environment may promote immediate, moderate-sized improvements in state body image. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. 21 CFR 880.2420 - Electronic monitor for gravity flow infusion systems.

    Science.gov (United States)

    2010-04-01

    ... and Personal Use Monitoring Devices § 880.2420 Electronic monitor for gravity flow infusion systems. (a) Identification. An electronic monitor for gravity flow infusion systems is a device used to... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electronic monitor for gravity flow infusion...

  13. The uniformity study of non-oxide thin film at device level using electron energy loss spectroscopy

    Science.gov (United States)

    Li, Zhi-Peng; Zheng, Yuankai; Li, Shaoping; Wang, Haifeng

    2018-05-01

    Electron energy loss spectroscopy (EELS) has been widely used as a chemical analysis technique to characterize materials chemical properties, such as element valence states, atoms/ions bonding environment. This study provides a new method to characterize physical properties (i.e., film uniformity, grain orientations) of non-oxide thin films in the magnetic device by using EELS microanalysis on scanning transmission electron microscope. This method is based on analyzing white line ratio of spectra and related extended energy loss fine structures so as to correlate it with thin film uniformity. This new approach can provide an effective and sensitive method to monitor/characterize thin film quality (i.e., uniformity) at atomic level for thin film development, which is especially useful for examining ultra-thin films (i.e., several nanometers) or embedded films in devices for industry applications. More importantly, this technique enables development of quantitative characterization of thin film uniformity and it would be a remarkably useful technique for examining various types of devices for industrial applications.

  14. Characterization of tellurium-based films for NO{sub 2} detection

    Energy Technology Data Exchange (ETDEWEB)

    Tsiulyanu, D. [Technical University, Department of Physics, bul. Dacia 41, MD-2060 Kishinau (Moldova, Republic of)]. E-mail: tsiu@cni.md; Tsiulyanu, A. [Technical University, Department of Physics, bul. Dacia 41, MD-2060 Kishinau (Moldova, Republic of); Liess, H.-D. [University of the Bundeswehr Munich, Faculty of Electrical Engineering and Information Technology, Institute of Physics, D-85577 Neubiberg (Germany); Eisele, I. [University of the Bundeswehr Munich, Faculty of Electrical Engineering and Information Technology, Institute of Physics, D-85577 Neubiberg (Germany)

    2005-08-01

    Sensing characteristics of tellurium-based thin films for NO{sub 2} monitoring was studied systematically. The influence of contact materials, thermal treatment, temperature and thickness of the samples on the electrical conductivity and sensitivity to NO{sub 2} with respect to scanning electron microscopy analyses is given. The possibility is shown to optimize the properties of the films for the development of a simple and stable NO{sub 2} sensor device with rapid response/recovery time and low operating temperature. The sensing mechanism is discussed for the direct interaction of gaseous species with lone-pair electrons of chalcogen atoms.

  15. Self-Organized Ni Nanocrystal Embedded in BaTiO3 Epitaxial Film

    Directory of Open Access Journals (Sweden)

    Ge FF

    2010-01-01

    Full Text Available Abstract Ni nanocrystals (NCs were embedded in BaTiO3 epitaxial films using the laser molecular beam epitaxy. The processes involving the self-organization of Ni NCs and the epitaxial growth of BaTiO3 were discussed. With the in situ monitoring of reflection high-energy electron diffraction, the nanocomposite films were engineered controllably by the fine alternation of the self-organization of Ni NCs and the epitaxial growth of BaTiO3. The transmission electron microscopy and the X-ray diffraction characterization confirmed that the composite film consists of the Ni NCs layers alternating with the (001/(100-oriented epitaxial BaTiO3 separation layers.

  16. Probing the phase composition of silicon films in situ by etch product detection

    International Nuclear Information System (INIS)

    Dingemans, G.; Donker, M. N. van den; Gordijn, A.; Kessels, W. M. M.; Sanden, M. C. M. van de

    2007-01-01

    Exploiting the higher etch probability for amorphous silicon relative to crystalline silicon, the transiently evolving phase composition of silicon films in the microcrystalline growth regime was probed in situ by monitoring the etch product (SiH 4 ) gas density during a short H 2 plasma treatment step. Etch product detection took place by the easy-to-implement techniques of optical emission spectroscopy and infrared absorption spectroscopy. The phase composition of the films was probed as a function of the SiH 4 concentration during deposition and as a function of the film thickness. The in situ results were corroborated by Raman spectroscopy and solar cell analysis

  17. Solvent vapor annealing in the molecular regime drastically improves carrier transport in small-molecule thin-film transistors

    KAUST Repository

    Khan, Hadayat Ullah

    2013-04-10

    We demonstrate a new way to investigate and control the solvent vapor annealing of solution-cast organic semiconductor thin films. Solvent vapor annealing of spin-cast films of 6,13-bis(triisopropylsilylethynyl) pentacene (TIPS-Pn) is investigated in situ using quartz crystal microbalance with dissipation (QCM-D) capability, allowing us to monitor both solvent mass uptake and changes in the mechanical rigidity of the film. Using time-resolved grazing incidence wide angle X-ray scattering (GIWAXS) and complementary static atomic force microscopy (AFM), we demonstrate that solvent vapor annealing in the molecular regime can cause significant performance improvements in organic thin film transistors (OTFTs), whereas allowing the solvent to percolate and form a liquid phase results in catastrophic reorganization and dewetting of the film, making the process counterproductive. Using these lessons we devise processing conditions which prevent percolation of the adsorbed solvent vapor molecules for extended periods, thus extending the benefits of solvent vapor annealing and improving carrier mobility by nearly two orders of magnitude. Ultimately, it is demonstrated that QCM-D is a very powerful sensor of the state of the adsorbed solvent as well as the thin film, thus making it suitable for process development as well as in-line process monitoring both in laboratory and in future manufacturing settings. © 2013 American Chemical Society.

  18. Solvent vapor annealing in the molecular regime drastically improves carrier transport in small-molecule thin-film transistors

    KAUST Repository

    Khan, Hadayat Ullah; Li, Ruipeng; Ren, Yi; Chen, Long; Payne, Marcia M.; Bhansali, Unnat Sampatraj; Smilgies, Detlef Matthias; Anthony, John Edward; Amassian, Aram

    2013-01-01

    We demonstrate a new way to investigate and control the solvent vapor annealing of solution-cast organic semiconductor thin films. Solvent vapor annealing of spin-cast films of 6,13-bis(triisopropylsilylethynyl) pentacene (TIPS-Pn) is investigated in situ using quartz crystal microbalance with dissipation (QCM-D) capability, allowing us to monitor both solvent mass uptake and changes in the mechanical rigidity of the film. Using time-resolved grazing incidence wide angle X-ray scattering (GIWAXS) and complementary static atomic force microscopy (AFM), we demonstrate that solvent vapor annealing in the molecular regime can cause significant performance improvements in organic thin film transistors (OTFTs), whereas allowing the solvent to percolate and form a liquid phase results in catastrophic reorganization and dewetting of the film, making the process counterproductive. Using these lessons we devise processing conditions which prevent percolation of the adsorbed solvent vapor molecules for extended periods, thus extending the benefits of solvent vapor annealing and improving carrier mobility by nearly two orders of magnitude. Ultimately, it is demonstrated that QCM-D is a very powerful sensor of the state of the adsorbed solvent as well as the thin film, thus making it suitable for process development as well as in-line process monitoring both in laboratory and in future manufacturing settings. © 2013 American Chemical Society.

  19. Effect of substrate baking temperature on zinc sulfide and germanium thin films optical parameters

    Science.gov (United States)

    Liu, Fang; Gao, Jiaobo; Yang, Chongmin; Zhang, Jianfu; Liu, Yongqiang; Liu, Qinglong; Wang, Songlin; Mi, Gaoyuan; Wang, Huina

    2016-10-01

    ZnS and Ge are very normal optical thin film materials in Infrared wave. Studying the influence of different substrate baking temperature to refractive index and actual deposition rates is very important to promote optical thin film quality. In the same vacuum level, monitoring thickness and evaporation rate, we use hot evaporation to deposit ZnS thin film materials and use ion-assisted electron beam to deposit Ge thin film materials with different baking temperature. We measure the spectral transmittance with the spectrophotometer and calculate the actual deposition rates and the refractive index in different temperature. With the higher and higher temperature in a particular range, ZnS and Ge refractive index become higher and actual deposition rates become smaller. The refractive index of Ge film material change with baking temperature is more sensitive than ZnS. However, ZnS film actual deposition rates change with baking temperature is more sensitive than Ge.

  20. Impact of a film portrayal of a police officer with spinal cord injury on attitudes towards disability: a media effects experiment.

    Science.gov (United States)

    Reinhardt, Jan D; Pennycott, Andrew; Fellinghauer, Bernd A G

    2014-01-01

    The portrayal of disabled people in the media can influence the public's perception of disability in both positive and negative ways. In this article, an experimental before and after design is used to determine the effects of a short film on the attitudes of non-disabled and disabled persons concerning employment and productivity of persons with disabilities. Three questions were posed to 480 study participants prior to and following a short film featuring a police officer with paraplegia. Linear mixed models were used to assess the effects of time point and disability status on the responses. The non-disabled participants' ratings of eligibility for employment of a paraplegic man and estimates of the employment rate of disabled people were significantly enhanced following the film. Nevertheless, the film had no significant effects on the ratings given by participants with disabilities in terms of eligibility, employment rate or productivity. This investigation highlights the potentially important influence of media portrayal and coverage of people with disabilities on attitudes of the public concerning disability. Restrictions in participation may result from an interaction of persons with impairments with an environment that is dominated by negative attitudes towards disability The portrayal of disabled people in the media can influence the public's attitudes towards disability in both positive and negative ways In this experimental study, attitudes of the general public were significantly improved following viewing a short film featuring a positive media portrayal of a police officer with paraplegia.