WorldWideScience

Sample records for personal monitor exposed

  1. Personal radiation monitoring and assessment of doses received by radiation workers (1996)

    International Nuclear Information System (INIS)

    Morris, N.D.

    1996-12-01

    Since late 1986, all persons monitored by the Australian Radiation Laboratory have been registered on a data base which maintains records of the doses received by each individual wearer. At present, the Service regularly monitors approximately 30,000 persons, which is roughly 90 percent of those monitored in Australia, and maintains dose histories of over 75,000 people. The skin dose for occupationally exposed workers can be measured by using one of the five types of monitor issued by the Service: Thermoluminescent Dosemeter (TLD monitor), Finger TLD 3, Neutron Monitor, Special TLD and Environmental monitor. The technical description of the monitors is provided along with the method for calculating the radiation dose. 5 refs., 7 tabs., 5 figs

  2. Personal radiation monitoring and assessment of doses received by radiation workers (1991)

    International Nuclear Information System (INIS)

    Morris, N.D.

    1992-06-01

    The Australian Radiation Laboratory has operated a Personal Radiation Monitoring Service since the early 1930's so that people working with radiation can determine the radiation doses that they receive due to their occupation. Since late 1986, all persons monitored by the Service have been registered on a data base which maintains records of the doses received by each individual wearer. Ultimately, this data base will become a National Register of the doses received within Australia. At present, the Service regularly monitors approximately 20,000 persons, which is roughly 70 percent of those monitored in Australia, and maintains dose histories of over 35,000 people. The skin dose for occupationally exposed workers can be measured by using one of the four types of monitor issued by the Service: 1. Thermoluminescent Dosemeter (TLD monitor) 2. Finger TLD 3. Neutron Monitor 4. Special TLD. The technical description of the monitors is provided along with the method for calculating the radiation dose. 5 refs., 7 tabs., 4 figs

  3. Monitoring the genetic health of persons in Goiania accidentally exposed to ionizing radiation from caesium-137

    International Nuclear Information System (INIS)

    Da Cruz, A.D.; Glickman, B.W.

    1998-01-01

    This work describes the long term genetic monitoring of the Goiania population exposed to ionizing radiation from 137 Cs, using cytogenetic and molecular endpoints. Cytogenetically, micronucleus frequencies differentiated groups exposed to different levels of radiation. Two molecular methods were employed: 1) the hprt clonal assay, involving in vitro selection of 6-thioguanine-resistant hprt mutant clones which were characterized at the molecular level using RT-PCR and genomic analysis. Ionizing radiation exposure initially elevated hprt mutation frequency which gradually diminished, so that no significant increase was observed four and a half years after original exposure. The spectrum of hprt mutations recovered from ten individuals exposed to relatively high doses of radiation revealed a fourfold increase in the frequency of A:T → G:C transitions. The increase is consistent with the effects of ionizing radiation in prokaryotes and lower eukaryotes. Additionally, a twofold increase in the frequency of deletions was observed which may reflect radiation induced DNA strand breakage; 2) determination of microsatellite instability using fluorescent PCR and genomic DNA from mononuclear cells. The frequency distributions of somatic microsatellite alterations in exposed and non-exposed populations were not different. Our assay lacked sensitivity to discriminate between spontaneous and induced microsatellite instability and therefore, is not suitable for population monitoring. Finally, we estimated the risk associated with radiation exposure for the exposed Goiania population. The estimated genetic risk of dominant disorders in the first post-exposure generation was increased nearly twenty-fourfold. The risk of carcinogenesis was increased by a factor of 1.5. (author)

  4. Monitoring the genetic health of persons in Goiania accidentally exposed to ionizing radiation from caesium-137

    Energy Technology Data Exchange (ETDEWEB)

    Da Cruz, A D; Glickman, B W [Centre for Environmental Health, Department of Biology, University of Victoria, Victoria, BC (Canada)

    1998-12-01

    This work describes the long term genetic monitoring of the Goiania population exposed to ionizing radiation from {sup 137}Cs, using cytogenetic and molecular endpoints. Cytogenetically, micronucleus frequencies differentiated groups exposed to different levels of radiation. Two molecular methods were employed: (1) the hprt clonal assay, involving in vitro selection of 6-thioguanine-resistant hprt mutant clones which were characterized at the molecular level using RT-PCR and genomic analysis. Ionizing radiation exposure initially elevated hprt mutation frequency which gradually diminished, so that no significant increase was observed four and a half years after original exposure. The spectrum of hprt mutations recovered from ten individuals exposed to relatively high doses of radiation revealed a fourfold increase in the frequency of A:T {yields} G:C transitions. The increase is consistent with the effects of ionizing radiation in prokaryotes and lower eukaryotes. Additionally, a twofold increase in the frequency of deletions was observed which may reflect radiation induced DNA strand breakage; (2) determination of microsatellite instability using fluorescent PCR and genomic DNA from mononuclear cells. The frequency distributions of somatic microsatellite alterations in exposed and non-exposed populations were not different. Our assay lacked sensitivity to discriminate between spontaneous and induced microsatellite instability and therefore, is not suitable for population monitoring. Finally, we estimated the risk associated with radiation exposure for the exposed Goiania population. The estimated genetic risk of dominant disorders in the first post-exposure generation was increased nearly twenty-fourfold. The risk of carcinogenesis was increased by a factor of 1.5. (author)

  5. Occupational radiation exposure in Germany: many monitored persons = high exposure?

    International Nuclear Information System (INIS)

    Nitschke, J.

    1996-01-01

    Natural radiation affects the entire population in Germany, and most of Germany's inhabitants are exposed to medical radiation in their lifetime. Occupational radiation exposure, however, is a kind of exposure affecting only a limited and well-defined group of the population, and this radiation exposure has been recorded and monitored as precisely as technically possible ever since the radiation protection laws made occupational radiation exposure monitoring a mandatory obligation. Official personal dosimetry applying passive dosemeters in fact does not offer direct protection against the effects of ionizing radiation, as dosemeter read-out and dose calculation is a post-exposure process. But it nevertheless is a rewarding monitoring duty under radiation protection law, as is shown by the radiation exposure statistics accumulated over decades: in spite of the number of monitored persons having been increasing over the years, the total exposure did not, due to the corresponding improvements in occupational radiation protection. (orig.) [de

  6. Studies on persons exposed to plutonium

    International Nuclear Information System (INIS)

    Voelz, G.L.; Stebbings, J.H.; Hempelmann, L.H.; Haxton, L.K.; York, D.A.

    1978-01-01

    The results of four studies of persons exposed, or potentially exposed, to plutonium are summarized. The studies are: a five-year update on clinical examinations and health experience of 26 Manhattan District workers heavily exposed at Los Alamos in 1944 to 1945; a 30-year mortality follow-up of 224 white male workers with plutonium body burdens of 10 nCi or more; a review of cancer mortality rates between 1950 and 1969 among Los Alamos County, New Mexico, male residents, all of whom have worked in or have lived within a few kilometers of a major plutonium plant and other nuclear facilities; and a review of cancer incidence rates between 1969 and 1974 in male residents of Los Alamos County. No excess of mortality due to any cause was observed in the 224 male subjects with the highest plutonium exposures at Los Alamos. Clinical examinations of the Manhattan District workers, whose average age in 1976 was 56 years, show them to be active persons with diseases that are not unusual for their ages. The two deaths in this group over the past 30 years have not been due to cancer. Mortality and incidence data indicate no excess of lung cancer in Los Alamos County males

  7. The task of official personal monitoring in Germany using electronic dosimetry systems

    International Nuclear Information System (INIS)

    Huebner, Stephan; Wahl, Wolfgang; Busch, Frank; Martini, Ekkehard

    2008-01-01

    Full text: Since the establishment of the first German personal monitoring services as competent measuring bodies in the year 1952, official personal dosimetry is carried out using passive dosimeters such as film batches, RPL- and TL-dosimeters solely. On the other hand, electronic dosimeters are in use in some big institutions like Nuclear Power Plants, hospitals or industrial units for operational purposes. In most cases, these dosimeters are regulated by competent authorities. For more than 20 years electronic dosimeters proved their worth of being appropriate personal dosimeters. Since 2001 concepts to implement electronic personal dosimeters into the official individual monitoring of occupational exposed workers were developed in different research projects. The EU market of personal dosimetry changes to an open and competitive one, the number of outside workers, especially during the outages of Nuclear Power Plants increases, the landscape of customers is getting more and more heterogeneous. Being able to face these tasks of a sustainable personal monitoring requires the introduction of modern electronic dosimeters into to the official monitoring. Doing so, the needed prompt exchange of dose-data between different monitoring services as well as between the customers and the related monitoring service can be warranted. In cooperation with the industry, competent authorities and a research centre a method for official dosimetry using electronic dosimetry systems was developed, realised and tested successfully by the three big monitoring services of Germany. These investigations are supported by the German Federal Ministry for the Environment, Nature Conservation and Nuclear Safety. For this purpose a network between customers and monitoring services was built up in order to monitor people, who work in different places related to different measuring bodies in only one period of surveillance. (author)

  8. First assessment of individual monitoring of medical workers occupationally exposed to ionizing radiation in Burkina Faso

    International Nuclear Information System (INIS)

    Yakoro, A.; Nobila Ouédraogo, Salimata Traoré

    2010-01-01

    This paper reports the results of monitoring of medical workers occupationally exposed to ionizing radiation as a consequence of exposure to X-rays, from 2007 to 2010, in Burkina Faso. The radiation exposure monitoring was made with thermoluminescent dosimeters (TLD-100) type 0110 and the reader used was Harshaw 4500. The medical establishments. subscribers were provided with personal dosimeters (measuring Hp (10) and Hp (0.07)) and dosimeters for background and workplace exposure (H*10) measurement. The dosimeters have been worn for periods of 2 months each. The number of establishments subscribed and workers monitored has gradually increased from 4 radiology establishments with 13 workers monitored at September 2007 to 23 subscribers with 121 workers monitored at the end of April 2010. 13 establishments were still working without monitoring. From September 2007 to April 2010, no individual annual dose limit has really been reached. 88.16% of the 2 months dose values of personal dosimeters were below 0.1mSv, the detection limit and 96.61% of Hp (10) bimonthly values were below 3.33mSv. The workplace exposure monitoring values were often low (varying from 0.00mSv to 40.45mSv). 87.08% of the values of H*(10) were below 3.33mSv, the upper limit of Hp (10) for a period of 2 months. Low values of individual dose have also been recorded despite of high values of workplace monitoring. This allowed to state that the workers monitored were not exposed to a major risk. Nevertheless, 13 TLD have been lost and 3 damaged by subscribers (out of 1504 TLD provided). 26 times (out of 240), background measurement and workplace exposure monitoring dosimeters have been placed at the improper location. Therefore, sensitization of the establishments using ionizing radiation should be reinforced and the national regulations should impose radiation monitoring (author)

  9. Individual radiological monitoring for exposed personnel of Nuclear Fuel Plant at Pitesti

    International Nuclear Information System (INIS)

    Ivana, T.; Epure, Gh.

    2010-01-01

    In the activity of nuclear fuel fabrication of CANDU type, based on natural and depleted uranium, individual radiological monitoring of the personnel exposed to ionizing radiation is very carefully approached. For Nuclear Fuel Plant (NFP) facility, where uranium appears in bulk and itemized form, measures for individual radiological monitoring are established by Radiological Safety Manual (MSR) in accordance with national and international legislation. All NFP employees are classified in either category A or category B of exposure to ionizing radiation. The classification is a function of type of activity and magnitude of exposure. All the exposed personnel are monitored for external doses (from gamma radiation) by measuring the equivalent dose H p (10) with monthly frequency. The system used for external individual dosimetric monitoring is based on the thermoluminescent dosimeter (TLD) of PANASONIC type UD813AS14. The NFP incorporates an in-house dosimetric laboratory notified by Romanian regulatory body CNCAN (National Commission for Control of Nuclear Activities). The workers handling nuclear materials are exposed to internal intake of uranium, mainly by inhalation. For internal doses monitoring is included part of exposed employees working directly with radioactive open sources (pulverulent or liquid nuclear materials), UO 2 sinterable powder, green pellets, sintered pellets, scrap and radioactive effluents. The estimation of internal exposure is made quarterly using the results from radioactive airborne monitors operating in the working places. The internal dose of each person exposed to open sources is calculated taking into account the rate of breathing, the time spent at the work place and the dose-activity coefficient (variable function of uranium absorption rate). The total effective individual dose is obtained by summing the external dose and internal dose (E=E ext +E int ). For conformity, the total effective individual dose (E) is compared with dose

  10. Personality and psychopathological profiles in individuals exposed to mobbing.

    Science.gov (United States)

    Girardi, Paolo; Monaco, Edoardo; Prestigiacomo, Claudio; Talamo, Alessandra; Ruberto, Amedeo; Tatarelli, Roberto

    2007-01-01

    Increasingly, mental health and medical professionals have been asked to assess claims of psychological harm arising from harassment at the workplace, or "mobbing." This study assessed the personality and psychopathological profiles of 146 individuals exposed to mobbing using validity, clinical, and content scales of the Minnesota Multiphasic Personality Inventory 2. Profiles and factor analyses were obtained. Two major dimensions emerged among those exposed to mobbing: (a) depressed mood, difficulty in making decisions, change-related anguish, and passive-aggressive traits (b) somatic symptoms, and need for attention and affection. This cross-sectional pilot study provides evidence that personality profiles of mobbing victims and psychological damage resulting from mobbing may be evaluated using standardized assessments, though a longitudinal study is needed to delineate cause-and-effect relationships.

  11. UDS in lymphocytes of occupationally radiation exposed persons

    International Nuclear Information System (INIS)

    Tuschl, H.; Kovac, R.

    1982-01-01

    To determine a possible effect of low dose radiation on DNA repair processes, peripheral lymphocytes of mine workers exposed to 222 Rn in the thermal gallery of Badgastein (Austria) and employees of the Austrian Research Centre Seibersdorf, exposed to varying doses of gamma radiation, were investigated. The capacity for unscheduled DNA synthesis (UDS) induced by in vitro UV irradiation was measured by autoradiography of isolated lymphocytes of exposed persons and unexposed controls. In all 222 Rn-exposed mine workers a significant increase of UDS above control values could be observed. Gamma irradiation 31 mrad had a significant effect on UDS, indicating a stimulation of DNA repair capability by chronic low dose exposure. (Author)

  12. Heterogeneity among violence-exposed women: applying person-oriented research methods.

    Science.gov (United States)

    Nurius, Paula S; Macy, Rebecca J

    2008-03-01

    Variability of experience and outcomes among violence-exposed people pose considerable challenges toward developing effective prevention and treatment protocols. To address these needs, the authors present an approach to research and a class of methodologies referred to as person oriented. Person-oriented tools support assessment of meaningful patterns among people that distinguish one group from another, subgroups for whom different interventions are indicated. The authors review the conceptual base of person-oriented methods, outline their distinction from more familiar variable-oriented methods, present descriptions of selected methods as well as empirical applications of person-oriented methods germane to violence exposure, and conclude with discussion of implications for future research and translation between research and practice. The authors focus on violence against women as a population, drawing on stress and coping theory as a theoretical framework. However, person-oriented methods hold utility for investigating diversity among violence-exposed people's experiences and needs across populations and theoretical foundations.

  13. Personal dosimetric monitoring in Ukraine: current status and further development

    International Nuclear Information System (INIS)

    Chumak, V. V.; Musijachenkom, A. V.; Boguslavskaya, A. I.

    2003-01-01

    Presently Ukraine has mixed system for dosimetric monitoring. Nuclear power plants and some major nuclear facilities have their own dosimetry services, which are responsible for regular dosimetric monitoring of workers. Rest of occupationally exposed persons is monitored by dosimetry laboratories affiliated to the territorial authorities for sanitary and epidemiology supervision. In 2002-2003 Ukrainian Ministry of Health performed survey of the status of dosimetric monitoring and inventory of critical groups requiring such monitoring. Dosimetry services in Ukraine cover about 38,000 occupationally exposed workers, including 9,100 medical professionals, 16,400 employees of 5 nuclear power plants and ca.12,400 workers dealing with other sources of occupational exposure (industry, research). Territorial dosimetry services operate in 13 of 24 regions of Ukraine, using DTU-01 manual TLD readers produced with one exception in 1988-1990. The coverage of critical groups by dosimetric monitoring is variable and ranges from 38% to 100% depending on the region. Personnel of nuclear power plants (about 16,400 workers) is monitored by their own dosimetry services achieving absolute coverage of the main staff and temporary workers. Current inadequate status of dosimetric monitoring infrastructure in Ukraine demands an urgent elaboration of the united state system for monitoring and recording of individual doses. The proposed plan would allows to bring dosimetry infrastructure in Ukraine to the modern state which would be compatible with existing and future European and international radiation protection networks. Unitary structure of Ukraine, strong administrative command and good communications between regions of the country are positive factors in favour of efficient implementation of the proposed plan. Deficiencies are associated with limited funding of this effort. (authors)

  14. A Review of the New European Technical Recommendations for Monitoring Individuals Occupationally Exposed to External Radiation

    International Nuclear Information System (INIS)

    Dijk, J.W.E. van; Alves, J.G.; Ambrosi, P.; Bartlett, D.T.; Currivan, L.; Fantuzzi, E.; Kamenopoulou, V.

    2013-01-01

    This paper reviews the revised Technical Recommendations for Monitoring Individuals Occupationally Exposed to External Radiation as issued by the European Commission as Radiation Protection 160. These recommendations are aimed at all stakeholders in radiation protection dosimetry with an emphasis in the responsible technical staff of approved dosimetry services. This paper briefly touches each Chapter and ends with a more in depth section on the uncertainty evaluation of dose measurements. -- Highlights: ► Recommendations on all aspects of running an approved dosimetry service. ► Radiation protection framework. ► Metrology of personal dosimeters. ► QC and QA of individual monitoring

  15. PERSONAL FEATURES OF CHILDREN AND ADOLESCENTS ILL WITH RESPIRATORY TUBERCULOSIS EXPOSED AND NOT EXPOSED TO THE SOURCE OF INFECTION

    Directory of Open Access Journals (Sweden)

    N. V. Zolotova

    2017-01-01

    Full Text Available Specific personal features of 296 children and adolescents exposed to tuberculosis and those with unidentified exposure were comparatively analyzed. Children with unidentified exposure demonstrated psychic tension, poor self-control, poorly developed social communication skills which determined disruptive interpersonal relations and uneasy personal growth. Children exposed to tuberculosis in their families were characterized by judging didactive position towards their neighbors which was formed by dysfunctional patterns of relations in their parental families. Adolescent with unidentified exposure manifested the contrast combination of pre-morbid personal attitudes which had certain etiologic contribution to the development of borderline neurotic states. The higher level of destructive reactions in the interpersonal communication was observed in the adolescents exposed to tuberculosis in their families. Identified personal features are considered to be psychological factors determining the hyperactivation of adaptive systems at the pre-morbid state and consequent development of structural functional disorders in various systems of the host, as well as providing impact on the course of tuberculosis.

  16. Administrative norms on radiofrequency radiation for occupationally exposed persons

    International Nuclear Information System (INIS)

    Saxeboel, G.

    1982-01-01

    The report presents a proposal for administrative norms on radiofrequency (RF) radiation for occupationally exposed persons. The norms establish maximum allowable field exposure in a frequency range from 1 MHz too 300 GHz. (RF)

  17. Environmental Monitoring Of Microbiological Laboratory: Expose Plate Method

    International Nuclear Information System (INIS)

    Yahaya Talib; Othman Mahmud; Noraisyah Mohd Yusof; Asmah Mohibat; Muhamad Syazwan Zulkifli

    2013-01-01

    Monitoring of microorganism is important and conducted regularly on environment of microbiological laboratory at Medical Technology Division. Its objective is to ensure the quality of working environment is maintained according to microbial contamination, consequently to assure the quality of microbiological tests. This paper presents report of environmental monitoring since year 2007. The test involved was bacterial colony counts after the growth media was exposed to air at identified location. (author)

  18. Personal radiation monitoring with thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Miano, S.C.

    1987-01-01

    The technique of personal dosimetry used by SAPRA (Servico de Assessoria e Protecao Radiologica S/C Ltda., Brazil) is presented. Thermoluminescent monitors and CaSO 4 : Dy are used in pastilles united by teflon. Characteristics of the dosemeters are briefly reported. The system of thermoluminescent measurement, designed and constructed by SAPRA, and the system of personal monitoring are described. (M.A.C.) [pt

  19. Digital dosimetry and personal and environmental monitoring assembly

    International Nuclear Information System (INIS)

    Cerovac, Z.; Radalj, Z.; Prlic, I.; Cerovac, H.

    1996-01-01

    Film+TLD and film or TLD Dosimetry have a certain delay in dose reporting, since the reports on occupational doses are usually available to the users within 40 days after the actual exposure. This is particularly important when the dose is received within the short-time interval or when the radiation source has some technical failures. For this reason, the additional monitoring is recommendable. The common Dosimetry service in Croatia is well established and the data available shows that over 80% of occupationally exposed persons are working in medical facilities, mainly with x-ray sources. Dosimetry services in the country are providing three types of dosemeters, film dosemeter badge, film+TLD dosemeter badge or plane TLD badge. We have decided to introduce the palette of digital pocket dosemeters to be used at different workplaces occupationally exposed to ionizing radiation. After the first experience with the ALARA 1G digital dosemeter it came out that this type of ionizing radiation measuring device is suitable for the various non-occupational purposes. After some technical improvement and with some telecommunication electronics this device is usable as a point environmental measuring station. This means that the probe of the record any change in normal environmental radiation field, send the data to the central station and to raise alarm if necessary. That is why we have made a prototype for environmental monitoring able to be connected to any kind of telecommunication net. (author)

  20. Personal monitoring

    International Nuclear Information System (INIS)

    1995-01-01

    Sources of ionizing radiation have innumerable applications in the workplace. The potential exposures of the individual workers involved may need to be routinely monitored and records kept of their cumulative radiation doses. There are also occasions when it is necessary to retrospectively determine a dose which may have been received by a worker. This Module explains the basic terminology associated with personal monitoring and describes the principal types of dosimeters and other related techniques and their application in the workplace. The Manual will be of most benefit if it forms part of more comprehensive training or is supplemented by the advice of a qualified expert in radiation protection. Most of the dosimeters and techniques described in this Module can only be provided by qualified experts

  1. Lymphocytic subsets in occupationally exposed persons

    International Nuclear Information System (INIS)

    Tuschl, H.; Kovac, R.; Wottawa, A.

    1989-04-01

    The percentage of CD2, CD4, CD8 and NK cells of peripheral blood was investigated in persons occupationally exposed to very low doses of ionizing radiation. Investigations were carried out by monoclonal antibodies and flow-cytometry. While significant effects of age and smoking habits on the relative number of CD8 cells and CD4/CD8 ratios could be established, no influence of the very low radiation exposure on the profile of lymphocytic cells in blood was found, except a very slight effect on the relative number of total T cells (= CD2 cells). 7tabs., 2figs., 16refs. (Author)

  2. Studies on the hazard of leukaemia and cancer in persons occupationally exposed to radiation

    International Nuclear Information System (INIS)

    Streffer, C.

    1988-01-01

    The mortality rates of British radiologists in dependence of the duration of their radiation work are compared with the general mortality rate in England and Wales, the mortality rates of men of the social class 1 and the mortality rates of practicing physicians. It turns out that the mortality by malignant diseases (leukemia and cancer) of persons exposed to radiation at work in nuclear plants is not considerably higher than it is for comparable groups of persons not exposed to radiation. Tumour entities of the GI tract have not been found either in the British radiologists exposed to radiation. (DG) [de

  3. Urinary 90Sr concentration in occupationally exposed and nonexposed persons in Austria

    International Nuclear Information System (INIS)

    Irlweck, K.; Streit, S.

    1979-01-01

    Personnel monitoring at Seibersdorf Research Centre includes analysis of 90 Sr in urine of employees who handle low-level radioactive wastes. Results for the two year period 1976-77 are reported. 90 Sr concentrations were mainly between 0.5 and 5.0pCi/l, except in the cases of two employees who incorporated 90 Sr as a result of an accident. Urine samples from 21 non-exposed persons not employed at Seibersdorf all gave results below 2pCi/l. These results agree with a 90 Sr concentration of 0.2-2.0pCi/l of urine estimated from global fallout data. If individual differences, e.g. in metabolism, diet etc. are taken into account, it is concluded that a 90 Sr incorporation above fallout level should be assumed with certainty only if the 90 Sr concentration exceeds 5pCi/l of urine. (author)

  4. Cytogenetics observation and radiation influence evaluation of exposed persons in a discontinuous radiation exposure event

    International Nuclear Information System (INIS)

    Chen Ying; Liu Xiulin; Yang Guoshan; Ge Shili; Jin Cuizhen; Yao Bo

    2003-01-01

    The cytogenetics results and dose estimation of exposed and related persons in an discontinuous radiation exposure event were reported in this paper. According to dicentrics + ring and micronucleus results combined with clinical data, slight (middle) degree of subacute radiation symptom of the victim was diagnosed. A part of 52 examined persons were exposed to radiation in a certain degree

  5. [Cognitive impairments in persons exposed to radiation during the period of prenatal development].

    Science.gov (United States)

    Burtovaya, E Yu; Kantina, T E; Belova, M V; Akleyev, A V

    2015-01-01

    To assess the cognitive status in persons exposed to ionizing radiation in prenatal period. The study included in-utero exposed people (n = 77), and the comparison group (n = 73), which consisted of people who lived in the territories of the Chelyabinsk Oblast that were not radioactive. The following methods were used: clinical, clinical-psychological (Mini-Mental State Examination (MMSE), the WAIS test, the proverb interpretation task, neurophysiological (EEG) methods, laboratory-based methods (cholesterol, high and low-density lipoproteins, triglycerides, cortisol, melatonin), and methods of statistical data processing. The number of people with non-psychotic mental disorders with the prevalence of organic mental disorders (cognitive and asthenic) was significantly higher among in-utero exposed subjects. A neurophysiological study revealed more severe changes in the bioelectric brain activity with the presence of pathological and theta-rhythms in exposed persons. The clinical-psychological study revealed a significant decrease in the analytic/synthetic ability in exposed people and significantly lower level of the general and verbal IQ. These changes were accompanied by higher levels of cortisol and melatonin which led to the activation and tension of the adaptation mechanisms in in-utero exposed subjects.

  6. Guidelines for personal exposure monitoring of chemicals: Part III.

    Science.gov (United States)

    Hashimoto, Haruo; Yamada, Kenichi; Hori, Hajime; Kumagai, Shinji; Murata, Masaru; Nagoya, Toshio; Nakahara, Hirohiko; Mochida, Nobuyuki

    2018-01-25

    This Document, "Guidelines for personal exposure monitoring of chemicals" ("this Guideline"), has been prepared by "The Committee for Personal Exposure Monitoring" ("the Committee") of the Expert Division of Occupational Hygiene & Ergonomics, Japan Society for Occupational Health. Considering the background of the growing importance of personal exposure monitoring in risk assessment and the need to prepare for the introduction of monitoring using personal samplers from an administrative perspective in recent years, the Committee was organized in November 2012. The Committee has prepared this Guideline as a "practical guideline" for personal exposure monitoring, so as to offer proposals and recommendations to the members of the Japan Society for Occupational Health and to society in general. The scope of this Guideline covers all chemical substances and all related workplaces regarded as targets for general assessment and the management of risk. It thus is not to be considered to comment on legal regulations and methodology. The main text provides the basic methods and concepts of personal exposure monitoring, while 31 "Appendices" are provided in this Guideline throughout the series; technical descriptions, statistical bases, and actual workplace examples are provided in these appendices, to assist better understanding. The personal exposure monitoring described as per this Guideline is equivalent to an "expert-centered basic method to reasonably proceed with the assessment and management of risk at workplaces." It is considered that practicing and expanding on this method will significantly contribute in reforming the overall framework of occupational hygiene management in Japan.

  7. Guidelines for personal exposure monitoring of chemicals: Part IV.

    Science.gov (United States)

    Hashimoto, Haruo; Yamada, Kenichi; Hori, Hajime; Kumagai, Shinji; Murata, Masaru; Nagoya, Toshio; Nakahara, Hirohiko; Mochida, Nobuyuki

    2018-03-27

    This Document, "Guidelines for personal exposure monitoring of chemicals" ("this Guideline"), has been prepared by "The Committee for Personal Exposure Monitoring" ("the Committee") of the Expert Division of Occupational Hygiene & Ergonomics, Japan Society for Occupational Health. Considering the background of the growing importance of personal exposure monitoring in risk assessment and the need to prepare for the introduction of monitoring using personal samplers from an administrative perspective in recent years, the Committee was organized in November 2012. The Committee has prepared this Guideline as a "practical guideline" for personal exposure monitoring, so as to offer proposals and recommendations to the members of the Japan Society for Occupational Health and to society in general. The scope of this Guideline covers all chemical substances and all related workplaces regarded as targets for general assessment and the management of risk. It thus is not to be considered to comment on legal regulations and methodology. The main text provides the basic methods and concepts of personal exposure monitoring, while 31 "Appendices" are provided in this Guideline throughout the series; technical descriptions, statistical bases, and actual workplace examples are provided in these appendices, to assist better understanding. The personal exposure monitoring described as per this Guideline is equivalent to an "expert-centered basic method to reasonably proceed with the assessment and management of risk at workplaces." It is considered that practicing and expanding on this method will significantly contribute in reforming the overall framework of occupational hygiene management in Japan.

  8. Guidelines for personal exposure monitoring of chemicals: Part II.

    Science.gov (United States)

    Hashimoto, Haruo; Yamada, Kenichi; Hori, Hajime; Kumagai, Shinji; Murata, Masaru; Nagoya, Toshio; Nakahara, Hirohiko; Mochida, Nobuyuki

    2017-11-25

    This Document, "Guidelines for personal exposure monitoring of chemicals" ("this Guideline"), has been prepared by "The Committee for Personal Exposure Monitoring" ("the Committee") of the Expert Division of Occupational Hygiene & Ergonomics, Japan Society for Occupational Health. Considering the background of the growing importance of personal exposure monitoring in risk assessment and the need to prepare for the introduction of monitoring using personal samplers from an administrative perspective in recent years, the Committee was organized in November 2012. The Committee has prepared this Guideline as a "practical guideline" for personal exposure monitoring, so as to offer proposals and recommendations to the members of the Japan Society for Occupational Health and to society in general. The scope of this Guideline covers all chemical substances and all related workplaces regarded as targets for general assessment and the management of risk. It thus is not to be considered to comment on legal regulations and methodology. The main text provides the basic methods and concepts of personal exposure monitoring, while 31 "Appendices" are provided in this Guideline throughout the series; technical descriptions, statistical bases, and actual workplace examples are provided in these appendices, to assist better understanding. The personal exposure monitoring described as per this Guideline is equivalent to an "expert-centered basic method to reasonably proceed with the assessment and management of risk at workplaces." It is considered that practicing and expanding on this method will significantly contribute in reforming the overall framework of occupational hygiene management in Japan.

  9. Guidelines for personal exposure monitoring of chemicals: Part I.

    Science.gov (United States)

    Hashimoto, Haruo; Yamada, Kenichi; Hori, Hajime; Kumagai, Shinji; Murata, Masaru; Nagoya, Toshio; Nakahara, Hirohiko; Mochida, Nobuyuki

    2017-09-28

    This Document, "Guidelines for personal exposure monitoring of chemicals" ("this Guideline"), has been prepared by "The Committee for Personal Exposure Monitoring" ("the Committee") of the Expert Division of Occupational Hygiene & Ergonomics, Japan Society for Occupational Health. Considering the background of the growing importance of personal exposure monitoring in risk assessment and the need to prepare for the introduction of monitoring using personal samplers from an administrative perspective in recent years, the Committee was organized in November 2012. The Committee has prepared this Guideline as a "practical guideline" for personal exposure monitoring, so as to offer proposals and recommendations to the members of the Japan Society for Occupational Health and to society in general. The scope of this Guideline covers all chemical substances and all related workplaces regarded as targets for general assessment and the management of risk. It thus is not to be considered to comment on legal regulations and methodology. The main text provides the basic methods and concepts of personal exposure monitoring, while 31 "Appendices" are provided later in this Guideline throughout the series; technical descriptions, statistical bases, and actual workplace examples are provided in these appendices, to assist better understanding. The personal exposure monitoring described as per this Guideline is equivalent to an "expert-centered basic method to reasonably proceed with the assessment and management of risk at workplaces." It is considered that practicing and expanding on this method will significantly contribute in reforming the overall framework of occupational hygiene management in Japan.

  10. Guidelines for personal exposure monitoring of chemicals: Part V.

    Science.gov (United States)

    Hashimoto, Haruo; Yamada, Kenichi; Hori, Hajime; Kumagai, Shinji; Murata, Masaru; Nagoya, Toshio; Nakahara, Hirohiko; Mochida, Nobuyuki

    2018-05-25

    This Document, "Guidelines for personal exposure monitoring of chemicals" ("this Guideline"), has been prepared by "The Committee for Personal Exposure Monitoring" ("the Committee") of the Expert Division of Occupational Hygiene & Ergonomics, Japan Society for Occupational Health. Considering the background of the growing importance of personal exposure monitoring in risk assessment and the need to prepare for the introduction of monitoring using personal samplers from an administrative perspective in recent years, the Committee was organized in November 2012. The Committee has prepared this Guideline as a "practical guideline" for personal exposure monitoring, so as to offer proposals and recommendations to the members of the Japan Society for Occupational Health and to society in general. The scope of this Guideline covers all chemical substances and all related workplaces regarded as targets for general assessment and the management of risk. It thus is not to be considered to comment on legal regulations and methodology. The main text provides the basic methods and concepts of personal exposure monitoring, while 31 "Appendices" are provided in this Guideline throughout the series; technical descriptions, statistical bases, and actual workplace examples are provided in these appendices, to assist better understanding. The personal exposure monitoring described as per this Guideline is equivalent to an "expert-centered basic method to reasonably proceed with the assessment and management of risk at workplaces." It is considered that practicing and expanding on this method will significantly contribute in reforming the overall framework of occupational hygiene management in Japan.

  11. To monitor or not to monitor?: editorial

    International Nuclear Information System (INIS)

    Johns, T.F.

    1988-01-01

    After a brief discussion about results for occupational exposure in New Zealand and the UK, a short editorial raises a number of questions about personal dosimetry practice. These questions include whether the right people are being monitored and whether less attention should be paid to the monitoring of certain groups of workers who are occupationally exposed to external beta/gamma radiation, and more to the monitoring of workers or members of the general public who are exposed to higher doses from radon daughters, so as to focus attention on the areas where the largest savings in collective dose could be achieved. (U.K.)

  12. Intercomparison of personal radiation monitoring services in the Asia/Pacific region- our participation

    International Nuclear Information System (INIS)

    Dhond, R.V.; Worlikar, R.M.; Saralamma Nair, D.; Pathak, A.S.; Sankaran, M.P.; Shenoy, K.S.; Patel, P.H.

    1994-01-01

    Radiation Protection Services Division participated in the intercomparison of personal monitoring services in Asia/Pacific region during 1991-92 organised by Australian Radiation Laboratory (ARL). The exposed films returned by ARL were processed in our laboratory. The nature and energies of the incident radiations were identified and doses evaluated in terms of new operational quantities. The doses evaluated were within ± 20% except in two cases where energy determination did not match with the ARL values. The results are presented in the paper. (author). 1 ref., 3 tabs

  13. Performance test of personal RF monitor for area monitoring at magnetic confinement fusion facility

    International Nuclear Information System (INIS)

    Tanaka, M.; Uda, T.; Wang, J.; Fujiwara, O.

    2012-01-01

    For safety management at a magnetic confinement fusion-test facility, protection from not only ionising radiation, but also non-ionising radiation such as the leakage of static magnetic and electromagnetic fields is an important issue. Accordingly, the use of a commercially available personal RF monitor for multipoint area monitoring is proposed. In this study, the performance of both fast- and slow-type personal RF monitors was investigated by using a transverse electromagnetic cell system. The range of target frequencies was between 10 and 300 MHz, corresponding to the ion cyclotron range of frequency in a fusion device. The personal RF monitor was found to have good linearity, frequency dependence and isotropic response. However, the time constant for the electric field sensor of the slow-type monitor was much longer than that for the fast-type monitor. Considering the time-varying field at the facility, it is found that the fast-type monitor is suitable for multipoint monitoring at magnetic confinement fusion test facilities. (authors)

  14. Hepatitis B immunisation in persons not previously exposed to hepatitis B or with unknown exposure status

    DEFF Research Database (Denmark)

    Mathew, Joseph L; El Dib, Regina; Mathew, Preethy J

    2008-01-01

    The benefits and harms of hepatitis B vaccination in persons not previously exposed to hepatitis B infection or with unknown exposure status have not been established.......The benefits and harms of hepatitis B vaccination in persons not previously exposed to hepatitis B infection or with unknown exposure status have not been established....

  15. Glass badge dosimetry system for large scale personal monitoring

    International Nuclear Information System (INIS)

    Norimichi Juto

    2002-01-01

    Glass Badge using silver activated phosphate glass dosemeter was specially developed for large scale personal monitoring. And dosimetry systems such as an automatic leader and a dose equipment calculation algorithm were developed at once to achieve reasonable personal monitoring. In large scale personal monitoring, both of precision for dosimetry and confidence for lot of personal data handling become very important. The silver activated phosphate glass dosemeter has basically excellent characteristics for dosimetry such as homogeneous and stable sensitivity, negligible fading and so on. Glass Badge was designed to measure 10 keV - 10 MeV range of photon. 300 keV - 3 MeV range of beta, and 0.025 eV - 15 MeV range of neutron by included SSNTD. And developed Glass Badge dosimetry system has not only these basic characteristics but also lot of features to keep good precision for dosimetry and data handling. In this presentation, features of Glass Badge dosimetry systems and examples for practical personal monitoring systems will be presented. (Author)

  16. Quality control of thermoluminesce personal dose monitoring

    International Nuclear Information System (INIS)

    Shang Aiguo; He Wenchang; Zhao Fengtao

    2006-01-01

    In order to evaluate the influence factor to thermoluminesce personal dose monitoring result, the every question that can appear based on the fact was analyzed. The results show that the detector, annealing, measuring process can influence the monitoring result. It gives some measures to enhance monitoring quality. (authors)

  17. Radiological interference from personal articles in occupational radiation monitoring

    International Nuclear Information System (INIS)

    Krishnakumar, P.; Jayan, M.P; Pawar, V.J; Patil, S.L; Selvamani, N.; Vedram; Sureshkumar, M.K.; Chinnaesakki, S.

    2016-01-01

    This paper discusses the presence of radioactivity in some personal articles worn on sacred thread and the related difficulties faced by health physicists during occupational radiation monitoring in nuclear facilities. In an incident, the portal monitor installed at the exit gate of a nuclear facility indicated contamination on self of a radiation worker while passing through it. The worker was therefore, subjected to thorough check for external contamination by the plant health physicist, using a pan-cake contamination monitor. All the clothing of the person was also checked for contamination. On further detailed examination, a dark brownish personal article hanging on a sacred thread from his neck was found to be the source of contamination. This presentation aims at giving information to the health physics community on the possibility of such interferences during personal monitoring in nuclear facilities

  18. Analysis of uranium in urine of persons occupationaly exposed

    International Nuclear Information System (INIS)

    Nunes, S.C.

    1985-01-01

    A technique of uranium analysis in urine of persons occupationaly exposed, using the fluorimetric method is proposed. Two procedures for the determination are presented: the first employs platinum dishes, obtaining a detection limit of 1 ppb and the second one, using aluminium dishes, shows a detection limit of 100 ppb. Uranium and urine physico-chemical characteristics are described, as well as norms for the exposition of workers to uranium. (M.A.C.) [pt

  19. Health protection of persons occupationally exposed to ionising radiation in Croatia

    International Nuclear Information System (INIS)

    Zavalic, M.

    2005-01-01

    The aim of this study was to investigate the health condition of workers occupationally exposed to ionising radiation. The results for 1406 workers exposed to ionising radiations, who were regularly examined in 2004, were analysed using Statistica 5.0. The analysis included workers' case histories, frequency of illnesses and causes of temporary or permanent work disability. Of 1406 workers, 16 (1.13%) were found permanently disabled; in 11 the cause of disability was lens opacity, in 2 persistent trombocitophenia, and in 2 malignant tumour. Twenty-four workers were temporarily disabled, of whom 5 due to pregnancy. Thrombocytopenia was found in 12 men and only one woman. Anaemia was found in 4 women; dicentric chromosomes were the cause of temporary disability in one person, and tuberculosis in one person. Medical examinations of Croatian workers confirm low occupational exposure to ionising radiation. With this type of radiation, the established lens impairments could not be characterised as occupational. The two malignant tumours however were recognised as occupational diseases.(author)

  20. Real-time personal exposure and health condition monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Saitou, Isamu; Kanda, Hiroaki; Asai, Akio; Takeishi, Naoki; Ota, Yoshito [Hitachi Aloka Medical, Ltd., Measuring Systems Engineering Dept., Tokyo (Japan); Hanawa, Nobuhiro; Ueda, Hisao; Kusunoki, Tsuyoshi; Ishitsuka, Etsuo; Kawamura, Hiroshi [Japan Atomic Energy Agency, Oarai Research and Development Center, Oarai, Ibaraki (Japan)

    2012-03-15

    JAEA (Japan Atomic Energy Agency) and HAM (Hitachi Aloka Medical, Ltd) have proposed novel monitoring system for workers of nuclear facility. In these facilities, exposure management for workers is mainly used access control and personal exposure recordings. This system is currently only for reports management but is not confirmative for surveillance when work in progress. Therefore, JAEA and HAM integrate access control and personal exposure recordings and two real-time monitoring systems which are position sensing and vital sign monitor. Furthermore change personal exposure management to real-time management, this system integration prevents workers from risk of accidents, and makes possible take appropriate action quickly. This novel system is going to start for tentative operation, using position sensing and real-time personal dosimeter with database in Apr. 2012. (author)

  1. A cytogenetic study on persons exposed to 241Am-Be neutron source

    International Nuclear Information System (INIS)

    Bai Yushu; Zhang Xiuxia; Guan Shurong; Xie Feng; Lu Meiying

    1988-01-01

    An 241 Am-Be neutron source of 120 millicrocurie was stolen by a boy on April the 3rd, 1982. He brought it to his home. The neutron source was broken and the radioactive substance contaminated the whole family. He and his other family members did not leave the contaminated environment for 70 days. There were altogether 14 persons exposed to the radioactive substances. Chromosome aberrations of peripheral blood lymphocytes of six exposed cases were analysed on an early day of June 1982. The exposure doses were estimated by the frequency of chromosome aberration. Biological dose absorbed by the boy who stole the source was about 96 ∼ 128 mGy (physical dose about 120 mGy), the others were about 10 ∼ 30 mGy (physical dose about 10 ∼ 30 mGy). The results indicated that biological dose were quite approximate to the physical doses. One and half years after the accident, the analysis of stable chromosome aberrations for 14 exposed persons showed that the frequencies of chromosome aberrations of the irradiated individuals were still higher than those of the controls. The differences between them are very significant

  2. Automated personal dosimetry monitoring system for NPP

    International Nuclear Information System (INIS)

    Chanyshev, E.; Chechyotkin, N.; Kondratev, A.; Plyshevskaya, D.

    2006-01-01

    Full text: Radiation safety of personnel at nuclear power plants (NPP) is a priority aim. Degree of radiation exposure of personnel is defined by many factors: NPP design, operation of equipment, organizational management of radiation hazardous works and, certainly, safety culture of every employee. Automated Personal Dosimetry Monitoring System (A.P.D.M.S.) is applied at all nuclear power plants nowadays in Russia to eliminate the possibility of occupational radiation exposure beyond regulated level under different modes of NPP operation. A.P.D.M.S. provides individual radiation dose registration. In the paper the efforts of Design Bureau 'Promengineering' in construction of software and hardware complex of A.P.D.M.S. (S.H.W. A.P.D.M.S.) for NPP with PWR are presented. The developed complex is intended to automatize activities of radiation safety department when caring out individual dosimetry control. The complex covers all main processes concerning individual monitoring of external and internal radiation exposure as well as dose recording, management, and planning. S.H.W. A.P.D.M.S. is a multi-purpose system which software was designed on the modular approach. This approach presumes modification and extension of software using new components (modules) without changes in other components. Such structure makes the system flexible and allows modifying it in case of implementation a new radiation safety requirements and extending the scope of dosimetry monitoring. That gives the possibility to include with time new kinds of dosimetry control for Russian NPP in compliance with IAEA recommendations, for instance, control of the equivalent dose rate to the skin and the equivalent dose rate to the lens of the eye S.H.W. A.P.D.M.S. provides dosimetry control as follows: Current monitoring of external radiation exposure: - Gamma radiation dose measurement using radio-photoluminescent personal dosimeters. - Neutron radiation dose measurement using thermoluminescent

  3. Privacy by design in personal health monitoring.

    Science.gov (United States)

    Nordgren, Anders

    2015-06-01

    The concept of privacy by design is becoming increasingly popular among regulators of information and communications technologies. This paper aims at analysing and discussing the ethical implications of this concept for personal health monitoring. I assume a privacy theory of restricted access and limited control. On the basis of this theory, I suggest a version of the concept of privacy by design that constitutes a middle road between what I call broad privacy by design and narrow privacy by design. The key feature of this approach is that it attempts to balance automated privacy protection and autonomously chosen privacy protection in a way that is context-sensitive. In personal health monitoring, this approach implies that in some contexts like medication assistance and monitoring of specific health parameters one single automatic option is legitimate, while in some other contexts, for example monitoring in which relatives are receivers of health-relevant information rather than health care professionals, a multi-choice approach stressing autonomy is warranted.

  4. Individual doses' register of occupationally exposed persons in the Republic of Moldova

    International Nuclear Information System (INIS)

    Hustuc, A.; Chiruta, Iu.

    2009-01-01

    The storage and processing of the data acquired through different monitoring techniques are of vital importance for controlling the individual doses of the occupationally exposed workers facilitating the determination of exposure pathway and furthering the policy of radiological protection. The use of the data bases for the evidence of the individual doses of the occupationally exposed workers to the ionizing radiation is useful in studies of risks and potential exposure, and in future epidemiological studies. (authors)

  5. Studies on health risks to persons exposed to plutonium

    International Nuclear Information System (INIS)

    Voelz, G.L.; Stebbings, J.H. Jr.; Healy, J.W.; Hempelmann, L.H.

    1979-01-01

    Two studies on Los Alamos workers exposed to plutonium have shown no increase in cancers of the lung, bone, and liver, three principal cancers of interest following plutonium deposition. A clinical study of 26 workers exposed 32 years ago shows no cases of cancer other than two skin cancers that were excised successfully. A mortality study of 224 workers, all persons with estimated deposition of 10 nCi or moe in 1974, showed no excess of mortality due to any cause. No bone or liver cancers were present, while one death due to lung cancer was observed as compared to an expected three cases. These negative findings on such small groups are not able to prove or disprove the validity of commonly used risk estimates as recommended in the 1972 BEIR and 1977 UNSCEAR reports, but the data do indicate that much higher risk estimates are not warranted

  6. Studies on health risks to persons exposed to plutonium

    Energy Technology Data Exchange (ETDEWEB)

    Voelz, G.L.; Stebbings, J.H. Jr.; Healy, J.W.; Hempelmann, L.H.

    1979-01-01

    Two studies on Los Alamos workers exposed to plutonium have shown no increase in cancers of the lung, bone, and liver, three principal cancers of interest following plutonium deposition. A clinical study of 26 workers exposed 32 years ago shows no cases of cancer other than two skin cancers that were excised successfully. A mortality study of 224 workers, all persons with estimated deposition of 10 nCi or moe in 1974, showed no excess of mortality due to any cause. No bone or liver cancers were present, while one death due to lung cancer was observed as compared to an expected three cases. These negative findings on such small groups are not able to prove or disprove the validity of commonly used risk estimates as recommended in the 1972 BEIR and 1977 UNSCEAR reports, but the data do indicate that much higher risk estimates are not warranted.

  7. Fine PM measurements: personal and indoor air monitoring.

    Science.gov (United States)

    Jantunen, M; Hänninen, O; Koistinen, K; Hashim, J H

    2002-12-01

    This review compiles personal and indoor microenvironment particulate matter (PM) monitoring needs from recently set research objectives, most importantly the NRC published "Research Priorities for Airborne Particulate Matter (1998)". Techniques and equipment used to monitor PM personal exposures and microenvironment concentrations and the constituents of the sampled PM during the last 20 years are then reviewed. Development objectives are set and discussed for personal and microenvironment PM samplers and monitors, for filter materials, and analytical laboratory techniques for equipment calibration, filter weighing and laboratory climate control. The progress is leading towards smaller sample flows, lighter, silent, independent (battery powered) monitors with data logging capacity to store microenvironment or activity relevant sensor data, advanced flow controls and continuous recording of the concentration. The best filters are non-hygroscopic, chemically pure and inert, and physically robust against mechanical wear. Semiautomatic and primary standard equivalent positive displacement flow meters are replacing the less accurate methods in flow calibration, and also personal sampling flow rates should become mass flow controlled (with or without volumetric compensation for pressure and temperature changes). In the weighing laboratory the alternatives are climatic control (set temperature and relative humidity), and mechanically simpler thermostatic heating, air conditioning and dehumidification systems combined with numerical control of temperature, humidity and pressure effects on flow calibration and filter weighing.

  8. Worker-specific exposure monitor and method for surveillance of workers

    International Nuclear Information System (INIS)

    Lovejoy, M.L.; Peeters, J.P.; Johnson, A.W.

    2000-01-01

    This invention relates to a person-specific monitor that provides sensor information regarding hazards to which the person is exposed and means to geolocate the person at the time of the exposure. The monitor also includes means to communicate with a remote base station. Information from the monitor can be downloaded at the base station for long term storage and analysis. The base station can also include means to recharge the monitor

  9. Elementary introduction for personal dose monitoring

    International Nuclear Information System (INIS)

    Bai Guang

    2004-01-01

    According to national laws and regulations, personnel who work with radiation must wear personal dosimeters and receive personal dose monitoring (PDM) provided by professional establishments, which are qualified for this purpose and certificated by the authorities. In this paper, the author gives a brief discussion concerning the Regulations & Purpose of PDM and the historical lessons in accident exposure without PDM. At last, it is pointed out that the PDM provided by the third-party commercial organizations is becoming the trend in this field. (author)

  10. USE OF PORTABLE GAMMA SPECTROMETERS FOR IDENTIFYING PERSONS EXPOSED IN A NUCLEAR CRITICALITY

    Energy Technology Data Exchange (ETDEWEB)

    Veinot, K. G. [Y-12 National Security Complex; Gose, B. T. [Y-12 National Security Complex; Bogard, James S [ORNL

    2009-01-01

    At Y-12 triage-style assessments are used to identify persons potentially exposed to high doses from criticality accident radiations using portable instruments by assessing the presence of activated sodium atoms in a person's blood. Historically, simple hand-held Geiger-Mueller (G-M) probes were used for these purposes although it was recognized that, since these instruments contain no information on incident photon energy, it was impossible to differentiate between photons emitted by contamination on the potentially exposed worker from activation of sodium in the person s blood. This works examines the use of a portable gamma spectrometer for assessing blood sodium activation. Irradiations of a representative phantom were performed using two neutron source configurations (unmoderated and polyethylene-moderated 252Cf) and measurements were made using the spectrometer and a G-M detector following irradiation. Detection limits in terms of personnel neutron dose are given for two neutron fields representing metaland solution criticality spectra. Both Geiger-Mueller and spectrometer results indicate a low minimum detectable neutron dose indicating that both instrument are useful as an emergency response instrument. The spectrometer has the added benefit of discriminating between surface contamination and blood sodium activation.

  11. USE OF PORTABLE GAMMA SPECTROMETERS FOR IDENTIFYING PERSONS EXPOSED IN A NUCLEAR CRITICALITY

    International Nuclear Information System (INIS)

    Veinot, K.G.; Gose, B.T.; Bogard, James S.

    2009-01-01

    At Y-12 triage-style assessments are used to identify persons potentially exposed to high doses from criticality accident radiations using portable instruments by assessing the presence of activated sodium atoms in a person's blood. Historically, simple hand-held Geiger-Mueller (G-M) probes were used for these purposes although it was recognized that, since these instruments contain no information on incident photon energy, it was impossible to differentiate between photons emitted by contamination on the potentially exposed worker from activation of sodium in the persons blood. This works examines the use of a portable gamma spectrometer for assessing blood sodium activation. Irradiations of a representative phantom were performed using two neutron source configurations (unmoderated and polyethylene-moderated 252Cf) and measurements were made using the spectrometer and a G-M detector following irradiation. Detection limits in terms of personnel neutron dose are given for two neutron fields representing metal and solution criticality spectra. Both Geiger-Mueller and spectrometer results indicate a low minimum detectable neutron dose indicating that both instrument are useful as an emergency response instrument. The spectrometer has the added benefit of discriminating between surface contamination and blood sodium activation.

  12. Assessment of methodology for 131I determination in workers exposed to incorporation

    International Nuclear Information System (INIS)

    Cerchetti, Maria L.; Arguelles, Maria G.

    2005-01-01

    In this work a technique used to monitor internal contamination of workers exposed to Iodine-131 incorporation from Radioisotope Production Plant was assessed. For the measurements of workers a NaI(Tl) EG and G ORTEC 905-1 were used in specific geometry, and data acquisition was controlled with Maestro TM software. Phantom has been used for calibration of efficiency of detectors placed in the same position as the real monitored person. Moreover, background counting was evaluated by statistical analysis for determination of protocol counting. The results obtained were analyzed under two models for calculating the decision threshold (Lc), and the minimum detectable activity (MDA), finally total uncertainty was calculated. Mean of efficiency was de 0.13% (RSD 6.7%) N = 43 D 6,7%, the MDA was 224 Bq (95% NC), and total propagated uncertainty was ± 13%. We obtained an effective evaluation of thyroid monitoring system for measurement of Iodine-131 in occupationally exposed persons. (author)

  13. Artificial stone dust-induced functional and inflammatory abnormalities in exposed workers monitored quantitatively by biometrics.

    Science.gov (United States)

    Ophir, Noa; Shai, Amir Bar; Alkalay, Yifat; Israeli, Shani; Korenstein, Rafi; Kramer, Mordechai R; Fireman, Elizabeth

    2016-01-01

    The manufacture of kitchen and bath countertops in Israel is based mainly on artificial stone that contains 93% silica as natural quartz, and ∼3500 workers are involved in cutting and processing it. Artificial stone produces high concentrations of silica dust. Exposure to crystalline silica may cause silicosis, an irreversible lung disease. Our aim was to screen exposed workers by quantitative biometric monitoring of functional and inflammatory parameters. 68 exposed artificial stone workers were compared to 48 nonexposed individuals (controls). Exposed workers filled in questionnaires, and all participants underwent pulmonary function tests and induced sputum analyses. Silica was quantitated by a Niton XL3 X-ray fluorescence spectrometer. Pulmonary function test results of exposed workers were significantly lower and induced sputa showed significantly higher neutrophilic inflammation compared to controls; both processes were slowed down by the use of protective measures in the workplace. Particle size distribution in induced sputum samples of exposed workers was similar to that of artificial stone dust, which contained aluminium, zirconium and titanium in addition to silica. In conclusion, the quantitation of biometric parameters is useful for monitoring workers exposed to artificial stone in order to avoid deterioration over time.

  14. Cytogenetic monitoring of personnel occupationally exposed to microwave radiation of GEM radar

    International Nuclear Information System (INIS)

    Garaj-Vrhovac, Vera; Gajski, Goran; Brumen, Vlatka

    2008-01-01

    In the present study we analyzed and followed-up on the DNA damaging effects of microwave radiation of GEM radar equipment within microwave field of 10 μW/cm 2 to 10 mW/cm 2 in personnel occupationally exposed to frequency range of 1.5 GHz to 10.9 GHz. The single cell gel electrophoresis (SCGE)/comet assay as a tool for the bio monitoring of individuals accidentally, environmentally or occupationally exposed to physical or chemical agents was used to evaluate possible genotoxic effect on peripheral human blood lymphocytes. The comet assay is a method that allows efficient determination of single strand breaks (SSB) and double-strand breaks (DSB), as well as alkali-labile sites in the DNA of single cells. The comet assay was carried out under alkaline conditions. We measured the baseline comet assay effect in whole blood samples. Parameter of the comet assay was studied in workers occupationally exposed to microwave radiation of GEM radar and in corresponding unexposed control subjects. It was found that in the subjects who were occupationally exposed to microwave radiation, the levels of DNA damage increased compare to control group and showed interindividual variations. As a measure of DNA damage tail length was used, calculated from the centre of the head and presented in micrometers (μm). Mean value of exposed group was 13.54±1.44 as opposed to control mean value that was 13.15±1.39. Differences between mean tail lengths were statistically significant (P<0.05, ANOVA). The results of this study indicate that individuals occupationally exposed to microwave frequency of GEM radar equipment may experience an increased genotoxic risk, emphasizing the importance of individual bio monitoring, limiting exposure and radiation safety programs. (author)

  15. Biological monitoring results for cadmium exposed workers.

    Science.gov (United States)

    McDiarmid, M A; Freeman, C S; Grossman, E A; Martonik, J

    1996-11-01

    As part of a settlement agreement with the Occupational Safety and Health Administration (OSHA) involving exposure to cadmium (Cd), a battery production facility provided medical surveillance data to OSHA for review. Measurements of cadmium in blood, cadmium in urine, and beta 2-microglobulin in urine were obtained for more than 100 workers over an 18-month period. Some airborne Cd exposure data were also made available. Two subpopulations of this cohort were of primary interest in evaluating compliance with the medical surveillance provisions of the Cadmium Standard. These were a group of 16 workers medically removed from cadmium exposure due to elevations in some biological parameter, and a group of platemakers. Platemaking had presented a particularly high exposure opportunity and had recently undergone engineering interventions to minimize exposure. The effect on three biological monitoring parameters of medical removal protection in the first group and engineering controls in platemakers is reported. Results reveal that both medical removal from cadmium exposures and exposure abatement through the use of engineering and work practice controls generally result in declines in biological monitoring parameters of exposed workers. Implications for the success of interventions are discussed.

  16. UDS and SCE in lymphocytes of persons occupationally exposed to low levels of ionizing radiation

    International Nuclear Information System (INIS)

    Tuschl, H.; Kovac, R.; Altmann, H.

    1983-03-01

    Unscheduled DNA synthesis induced by 'in vitro' UV-irradiation was investigated in lymphocytes of persons occupationally exposed to low doses of ionizing radiation (maximum registered radiation dose: 98 mrad/month). For radiation exposures >14 mrad/month, above background level, increased rates of UDS after in vitro UV-irradiation of lymphocytes were found. The bromodeoxyuridine differential chromatid labeling technique was applied to the examination of spontaneous and mytomycin C induced sister chromatid exchanges in the same population. No statistically significant difference could be determined in spontaneously occurring SCEs, while MMC induced SCEs were significantly reduced in persons exposed to radiation doses >14 mrad/month, thus indicating increased repair capability for DNA lesions inflicted by a second insult after protracted low dose irradiation. (Author) [de

  17. Development of personal dose monitoring system using wireless data transmission device

    International Nuclear Information System (INIS)

    Inui, Daisuke; Nakashima, Sadao

    2008-01-01

    Radiation workers working in radiation controlled area in nuclear power plants etc., are required to carry a dosimeters by regulation law. The workers are controlled daily on personal exposure dose by reading out the exposure dose information of the dosimeters with an area access control gate installed at the entrance of the radiation controlled area. This type of personal dose monitoring system has a problem that each worker can get his personal dose data only at the entrance of the radiation controlled area several times a day. We developed a system to get the real-time acquisition of personal dose data especially for workers working in a high dose area. This system is generally composed of a dosimeter with a wireless attachment, relay station, and monitor. Some relay stations set in main work places in the radiation controlled area can collect real-time personal dose data of each dosimeter carried by workers at the work place with the relay stations, and transmit it to the monitor to get personal dose data of individual workers. A wireless communication system between dosimeters and relay stations is applied to collect efficiently all personal dose data in the work place. (author)

  18. Analysis of reproductive function in persons exposed to chronic radiation

    Energy Technology Data Exchange (ETDEWEB)

    Kossenko, M.M.; Ostroumova, E.V.; Vyushkova, O.V. [Urals Research Center for Radiation Medicine, Chelyabinsk (Russian Federation)

    2000-05-01

    The purpose of the study was to analyze the reproductive function in individuals exposed to radiation in the riverside villages on the Techa in the Southern Urals. The exposure of the population, numbering 28000, occurred in 1950-1956 as a result of discharges into the river of radioactive wastes from the Mayak facility for processing weapon plutonium. The residents were exposed to chronic radiation, both external and internal. The range of exposure doses to gonads was sufficiently wide: 20-1270 mSv. However, the distribution of doses among the exposed individuals was ununiform, and the proportion of people whose dose was below 120 mGy accounted for 74%. The following characteristics of exposed women were analyzed: menstrual function, outcomes of pregnancy, birth rates, health status for newborns. The analysis of the menstrual function in exposed women showed that in persons exposed in childhood, menarche was registered at the age of 14.3 years, on the average (based on literature sources, menarche is attained at the age of 13 for unexposed population). The mean age at menopause was 47.9 years for exposed women (the respective mean value for Russia is 50.8 years). Pregnancy outcomes were analyzed in 9000 exposed women. The rate of medical and criminal abortions was estimated as 79 per 100 labors. The rate of spontaneous abortions for exposed women was slightly higher, 3.11%, than for controls, 2.30%; these difference, however, were statistically insignificant. The total loss of fetus or neonate (unfavorable outcomes of pregnancy: spontaneous abortions, stillbirths, early neonatal death) was estimated to be 4.58% at zero dose. Exposure to gonads at the dose 1 Sv, estimated using the above-indicated method, yielded 3% of additional unfavorable outcomes of pregnancy. It was shown, based on the analysis of birth rates for the Techa Cohort that they had not undergone any essential changes over the first 25 years of exposure compared to the respective coefficients for

  19. Analysis of reproductive function in persons exposed to chronic radiation

    International Nuclear Information System (INIS)

    Kossenko, M.M.; Ostroumova, E.V.; Vyushkova, O.V.

    2000-01-01

    The purpose of the study was to analyze the reproductive function in individuals exposed to radiation in the riverside villages on the Techa in the Southern Urals. The exposure of the population, numbering 28000, occurred in 1950-1956 as a result of discharges into the river of radioactive wastes from the Mayak facility for processing weapon plutonium. The residents were exposed to chronic radiation, both external and internal. The range of exposure doses to gonads was sufficiently wide: 20-1270 mSv. However, the distribution of doses among the exposed individuals was ununiform, and the proportion of people whose dose was below 120 mGy accounted for 74%. The following characteristics of exposed women were analyzed: menstrual function, outcomes of pregnancy, birth rates, health status for newborns. The analysis of the menstrual function in exposed women showed that in persons exposed in childhood, menarche was registered at the age of 14.3 years, on the average (based on literature sources, menarche is attained at the age of 13 for unexposed population). The mean age at menopause was 47.9 years for exposed women (the respective mean value for Russia is 50.8 years). Pregnancy outcomes were analyzed in 9000 exposed women. The rate of medical and criminal abortions was estimated as 79 per 100 labors. The rate of spontaneous abortions for exposed women was slightly higher, 3.11%, than for controls, 2.30%; these difference, however, were statistically insignificant. The total loss of fetus or neonate (unfavorable outcomes of pregnancy: spontaneous abortions, stillbirths, early neonatal death) was estimated to be 4.58% at zero dose. Exposure to gonads at the dose 1 Sv, estimated using the above-indicated method, yielded 3% of additional unfavorable outcomes of pregnancy. It was shown, based on the analysis of birth rates for the Techa Cohort that they had not undergone any essential changes over the first 25 years of exposure compared to the respective coefficients for

  20. Real-time personal dose monitoring and management system

    International Nuclear Information System (INIS)

    Zhang Zhiyong; Cheng Chang; Yang Huating; Liu Zhengshan; Deng Changming; Li Mei

    2000-01-01

    This paper mainly describes a real-time personal dose monitoring and management system. The system is composed of three parts that include SDM-98 semiconductor detector personal dosimeters, Data Readers and a Management System Software. It can be used for personal dose monitoring and management and other controlling actions in a radioactive controlled area. Adopting semiconductor detector and microcontroller, SDM-98 Personal Dosimeter is used to measure personal accumulated dose equivalent and dose rate caused by X-ray and Gamma ray. The results can be read directly on LCD. All the data stored in dosimeter can be transmitted into a data reader by infrared optical link. The alarm threshold can be adjusted successively in whole range of dose or dose rate. The Data Reader is an intelligent interface between the dosimeter and master computer. The data received from dosimeter will be sent to a master computer through RS-232 serial interface. According to the master computer's order, the Data Reader can turn on the dosimeter's power at entrance and shutdown it at exit. The Management System Software which written by Visual BASIC 5.0 runs on MS Win95. All the measuring data from dosimeters can be analyzed and treated according to requirements and stored in database. Therefore, some figures and tables relative to dose or rate can be shown on screen or printed out. (author)

  1. How conservative is routine personal dosimetry monitoring in diagnostic radiology?

    International Nuclear Information System (INIS)

    Boetticher, H. von; Lachmund, J.; Hoffmann, W.

    2007-01-01

    Purpose: Dose values obtained by official personal radiation exposure monitoring are often considered equivalent to the effective dose of a person. This paper provides estimates of the extent of deviation between the two dose concepts under various conditions. Materials and Methods: Doses for patients and personnel were measured using thermoluminescence dosimeters for five different geometries at three work settings in a radiology department. Patients and personnel were simulated with anthropomorphic phantoms. Different types of protective clothing as well as permanent protection shields were considered in the calculations. Results: Dose values obtained by official personal dose monitoring are conservative only for specific radiation protection situations. With state-of-the-art personal protective equipment (wrap-around style lead apron with thyroid shield), the ratio between effective dose and personal dose varies between 0.6 and 1.25. Without thyroid protection the official personal dose systematically underestimates the effective dose: for protective clothing with 0.5 mm lead equivalent without thyroid shielding, the effective dose exceeds the personal dose by factors between 1.7 and 3.1. If protective clothing with lead equivalent 0.35 mm is used, this factor varies between 1.1 and 1.82. (orig.)

  2. Mental and behavioural disorders in Belarusian persons exposed in utero to radiation following the Chernobyl accident

    International Nuclear Information System (INIS)

    Igumnov, S.A.

    2007-01-01

    Complete text of publication follows. Objectives - Investigation of mental health and psychosocial development of persons from Belarus exposed in utero to radiation following the Chernobyl accident in 1986. Methods - Ten year follow-up of 245 persons exposed in utero following the Chernobyl accident and 239 persons of the same age from non- or slightly contaminated regions. Psychiatric and psychosocial assessments were performed at the age 6-7 years, 10-12 years, and 15-16 years. Psychiatric diagnosis of the children in both groups was established by means of a semi-structured clinical interview based on the diagnostic criteria of the ICD-10, Chapter V (Mental and behavioural disorders). Results - The persons who were exposed to the influence of radionuclides antenatally showed a relative increase in mental and behavioral disorders compared to the control group. This was mainly due to the increased prevalence of cases of specific developmental disorders of speech and language, specific developmental disorders of motor function, emotional disorders and disorders of social functioning. Phobic anxiety disorders were the most common emotional disorders in both groups (27 cases - 10.8 % in the exposed group vs 17 cases - 6.8 % in the control group. The relative risk of the development of emotional disorders was 2.67 (P<0.001). There was no difference between the cases and control groups in terms of the prevalence of mental retardation, specific learning disorders, hyperkinetic disorders and other mental and behavioral disorders. At adolescent age there was also no difference in the prevalence of conduct disorders between the cases and the control groups. Conduct disorders were often associated with unfavorable psychological surroundings, including unsatisfactory family relations and learning difficulties at school. Conduct disorders at adolescent age (15-16) were closely correlated with hyperkinetic disorders (r=0.72; P<0.01), disorders of scholastic skills (r=0.72; P<0

  3. Use of personal radiation protection tools and individual dosimetric monitoring in a sample of interventional cardiologists in France, 2005-2009

    International Nuclear Information System (INIS)

    Jacob, S.; Bertrand, A.; Laurier, D.; Bernier, M.O.; Scanff, P.

    2014-01-01

    Interventional cardiologists (ICs) are repeatedly exposed to scattered ionising radiation during the cardiac procedures they perform, and radiation protection is an important issue for these medical professionals. The use of radiation protection tools is particularly relevant to this population. SISERI (Systeme d'Information de la Surveillance de l'Exposition aux Rayonnement Ionisants, that is, an information system for monitoring exposure to ionising radiation) is a register that stores personal dosimeter readings for dosimetric monitoring. This paper, based on data for a sample of French ICs from the O'CLOC epidemiological study, aims to provide an overview of the use of radiation protection equipment and dosimetric devices reported by ICs in a specific questionnaire as well as the dosimetric information found in the SISERI database for this population. Material and Methods - Annual information on interventional cardiology activity for the period from 01/01/2005 to 31/12/2009 was collected in an occupational questionnaire. ICs were asked to report the frequency in which they used individual dosimeter and radiation protection tools (lead apron, thyroid shield, eye-wear or face shield, ceiling-suspended shield) as follows: never (0% of the time), occasionally ( 50%), always (100%). We retrieved their medical radiation exposure information (monitored status and monthly effective doses) from the SISERI database for the period 2005-2009. Results - Information for 132 ICs (mean age in 2005 = 46 ± 7 years) was available. All ICs reported routine use of lead aprons, in contrast to their occasional use of lead eye-wear or face shields. During the study period, 49% reported systematic use of personal dosimeters, and 21% more regular use. On the other hand, 18% never used a dosimeter during this period. The SISTERI database included 92% of our population, 73% of whom had complete annual dose monitoring in SISERI (corresponding to at least 11 months per year of recorded

  4. Comparison of two personal ultraviolet index monitors for sun awareness in South Africa

    Directory of Open Access Journals (Sweden)

    Caradee Y. Wright

    2013-01-01

    Full Text Available Exposure to solar ultraviolet (UV radiation is known to have both adverse and beneficial consequences for human health. Sunburn and skin cancer are probably the most well-known acute and chronic adverse health impacts. These themes have recently been discussed in the media for the general public; consequently interest in sun protection is growing. The promotion of the use of practical personal strategies to reduce adverse health risks, such as healthy sun behaviour, sun protection mechanisms and solar ultraviolet radiation awareness tools, is increasing. One such tool is the personal UV index (UVI monitor, promoted commercially as a viable tool for sun awareness; however, such instruments have not been scientifically evaluated in a South African context. Here, two different types of personal UVI monitors, commercially available in South Africa, were compared with a research-grade UVB biometer for a continuous 7-h period on 02 March 2012 in Pretoria. One of the two personal UVI monitors showed reasonable agreement with the UVB biometer, whereas the other monitor overestimated UVI by up to 4 UVI units. When comparing two identical products manufactured by the same company, one monitor overestimated UVI twofold, suggesting inter-instrument variability may be a concern. Commercially available, personal UVI monitors should be used with caution as a public health tool for sun awareness in South Africa.

  5. Monitoring occupational exposure to ionizing radiation

    International Nuclear Information System (INIS)

    Button, J.B.C.

    1997-01-01

    A brief overview is presented of methods of monitoring occupational exposure to ionizing radiation together with reasons for such monitoring and maintaining dose histories of radiation occupationally exposed persons. The various Australian providers of external radiation monitoring services and the types of dosemeters they supply are briefly described together with some monitoring results. Biological monitoring methods, are used to determine internal radiation dose. Whole body monitors, used for this purpose are available at Australian Radiation Lab., ANSTO and a few hospitals. Brief mention is made of the Australian National Radiation Dose Register and its objectives

  6. What can be learned from epidemiologic studies of persons exposed to low doses of radiation?

    International Nuclear Information System (INIS)

    Gilbert, E.S.

    1993-04-01

    The main objective of radiation risk assessment is to determine the risk of various adverse health effects associated with exposure to low doses and low dose rates. Extrapolation of risks from studies of persons exposed at high doses (generally exceeding 1 Sv) and dose rates has been the primary approach used to achieve this objective. The study of Japanese atomic bomb survivors in Hiroshima and Nagasaki has played an especially important role in risk assessment efforts. A direct assessment of the dose-response function based on studies of persons exposed at low doses and dose rates is obviously desirable. This paper focuses on the potential of both current and future nuclear workers studies for investigating the dose-response functions at low doses, and also discusses analyses making use of the low dose portion of the atomic bomb survivor data. Difficulties in using these data are the statistical imprecision of estimated dose-response parameters, and potential bias resulting from confounding factors and from uncertainties in dose estimates

  7. Personal exposure versus monitoring station data for respirable particles

    Energy Technology Data Exchange (ETDEWEB)

    Sega, K; Fugas, M

    1982-01-01

    Personal exposure to respirable particles of 12 subjects working at the same location, but living in various parts of Zagreb, was monitored for 7 consecutive days and compared with simultaneously obtained data from the outdoor network station nearest to subject's home. Although personal exposure is related to the outdoor pollution, other sources play a considerable role. Indoor exposure takes, on the average, more than 80% of the total time. The ratio between average personal exposure and respirable particle levels in the outdoor air decreases with the increased outdoor concentration (r = -0.93), indicating that this relationship might serve as a basis for a rough estimate of possible personal exposure.

  8. Investigations on neurotoxicity of chemical substances at the workplace. VII. Longitudinal study with determination of nerve conduction velocities in persons occupationally exposed to styrene

    Energy Technology Data Exchange (ETDEWEB)

    Triebig, G.; Schaller, K.H.; Valentin, H.

    1985-01-01

    The aim of this longitudinal study was to investigate whether long-term exposure to styrene is associated with functional disorders of the peripheral nervous system. Eleven workers (age: 24 to 54 years) of a polyester resin boat industry were studied neurophysiologically and biochemically in 1980 and 1983. The duration of styrene-exposure varied from 3 to 7 years, with a median of 4 years. The control group was comprised of 11 non-styrene-exposed workers of similar age. Air Monitoring with passive samplers was performed on different days for each person. The mean styrene concentrations were 114, 97 and 92 ppm respectively and therefore in the magnitude of the current MAK-value of 100 ppm in the Federal Republic of Germany (FRG). For Biological Monitoring styrene in blood (S-B) and mandelic acid (MA) as well as phenylglyoxylic-acid (PGA) in urine were determined in post-shift samples. The median values for MA at four different sampling times were 816, 1660, 1101 and 1224 mg/g creatinine and for PGA 200, 273, 342 and 336 mg/g creatinine respectively. These levels were below the current Biologischer Arbeitsstoff Toleranzwert (BAT-Wert) for MA (2000 mg/l) and MA + PGA (2500 mg/l). The S-B concentrations ranged from 0.05 mg/l to 3.26 mg/l, with mean values of 0.92 and 0.70 mg/l. The nerve conduction velocities (NCV) of motor and sensory nerve fibers (N. ulnaris and/or N. medianus) showed no significant differences between styrene-exposed workers and age-matched control persons. There were no hints of dose-effect-relationships by correlation analyses. Furthermore the follow-up determination revealed no significant changes regarding NCV.

  9. Personal monitoring of 218Po and 214Po radionuclide deposition onto individuals under normal environmental exposure conditions

    International Nuclear Information System (INIS)

    Eatough, J.P.; Worley, A.; Moss, G.R.

    1999-01-01

    Personal dosemeters have been utilized to monitor the deposition of the radon decay products 218 Po and 214 Po onto individuals under normal environmental exposure conditions. Each detector consists of TASTRAK alpha-sensitive plastic incorporated into an ordinary working wristwatch. Subsequent analysis provides energy discrimination of the detected alpha-particle decays, and allows events from the individual radon decay products 218 Po and 214 Po, attached to the detector surface, to be uniquely identified. Assuming similar deposition onto skin and detector surfaces, the activity per unit area of deposited radionuclides can be determined for exposed skin. Forty-one personal dosemeters were issued to volunteers selected through the hospital medical physics departments at Reading, Northampton, Exeter and Plymouth. Each volunteer was also issued with a personal radon dosemeter to determine their individual radon exposure. The volunteers wore the two dosemeters simultaneously and continuously for a period of around one month. Correlations were observed between the radon exposure of the individual and the activity per unit area of 218 Po and 214 Po on the detector surface. From these correlations it can be estimated that at the UK average radon exposure of 20 Bq m -3 , the number of decays/cm 2 /year on continuously exposed skin surface is between 3500 and 28 000 for 218 Po, and between 7000 and 21 000 for 214 Po. These results can be combined with theoretical modelling of the dose distribution in the skin to yield the alpha-particle radiation dose to any identified target cells. (author)

  10. Personalized USB Biosensor Module for Effective ECG Monitoring.

    Science.gov (United States)

    Sladojević, Srdjan; Arsenović, Marko; Lončar-Turukalo, Tatjana; Sladojević, Miroslava; Ćulibrk, Dubravko

    2016-01-01

    The burden of chronic disease and associated disability present a major threat to financial sustainability of healthcare delivery systems. The need for cost-effective early diagnosis and disease prevention is evident driving the development of personalized home health solutions. The proposed solution presents an easy to use ECG monitoring system. The core hardware component is a biosensor dongle with sensing probes at one end, and micro USB interface at the other end, offering reliable and unobtrusive sensing, preprocessing and storage. An additional component is a smart phone, providing both the biosensor's power supply and an intuitive user application for the real-time data reading. The system usage is simplified, with innovative solutions offering plug and play functionality avoiding additional driver installation. Personalized needs could be met with different sensor combinations enabling adequate monitoring in chronic disease, during physical activity and in the rehabilitation process.

  11. Intercomparison of personal radiation monitoring services in the Asia/Pacific region

    International Nuclear Information System (INIS)

    Young, J.G.; Hargrave, N.J.

    1994-01-01

    The Australian Radiation Laboratory conducted an international intercomparison of personal radiation monitoring services in the Asia/Pacific region during 1991. Twenty nine organizations from sixteen countries took part in the study, with the People's Republic of China having eleven participants. Dosemeters incorporating thermoluminescent phosphors and conventional film were submitted for evaluation. Both types were irradiated at normal incidence on a phantom with 137 Cs gamma rays, X rays and beta radiation from a 90 Sr/ 90 Y source. Participants were requested to assess their dosemeters in terms of the new operational quantities of the ICRU for personal radiation monitoring, in particular the personal dose equivalents H p (0.07) and H p (10). (author)

  12. Personal dosimetry and area monitoring for neutrons and radon in workplaces

    International Nuclear Information System (INIS)

    Tommasino, L.

    2001-01-01

    The first successful applications of damage track detectors in radiation protection have been made in the early 1970s in personal dosimetry of neutrons, radon and its progenies. Most of the scientists actively engaged in the solution of the complex problem of personal neutron dosimetry by damage track detectors-SSNTD, have attempted to develop individual radon monitoring for exposure in mines by using the same SSNTDs. In late 1970s and the early 1980s, new radon monitoring devices based on SSNTDs have been developed to measure radon in soil, mainly for applications in uranium prospecting or more generally in earth sciences. Most of the radon monitors, developed since then for completely different applications in mind, have been used later for large scale survey of indoor radon. With the current implementation within Europe of the European Union Directive 96/29, applications of damage track detectors will increase drastically, specially for the assessment of the exposure of the workers to natural sources of radiation. In this case, the early work on personal neutron/radon dosimetry, is highly valuable to tackle these new problems of individual monitoring

  13. Biological monitoring of blood toluene in exposed printing shop workers; Biologisches Monitoring von Toluol am Beispiel belasteter Druckereiarbeiter

    Energy Technology Data Exchange (ETDEWEB)

    Hammer, K.D. [Hamburg Univ. (Germany). Ordinariat fuer Hygiene; Pietsch, S. [Hamburg Univ. (Germany). Ordinariat fuer Hygiene; Pfeiffer, E.H. [Hamburg Univ. (Germany). Ordinariat fuer Hygiene

    1993-11-01

    42 toluene exposed printing workers were monitored and the results compared with those of a control group of 45 blood donors. Monitoring was done by means of blood toluene and hippuric acid excretion measurements. The mean indoor air concentration of toluene amounted to 230 mg/m{sup 3}. The blood toluene averaged up to 830 {mu}g/l. The median of hippuric acid excretion was in the range of 0,405 mg/mg creatinine for the control group and 1,938 mg/mg creatinine for the exposed group respectively. Hippuric acid showed a positive correlation toward ORSA-tube toluene measurements with good significance (p=0,000). Considerable high individual deviations in toluene metabolism occurred, and were discussed as a result of smoking and drinking behavior. (orig.) [Deutsch] 42 Druckereiarbeiter, die einer Raumluft mit einer mittleren Toluolkonzentration von 230 {mu}g/m{sup 3} exponiert waren, wurden untersucht und die Ergebnisse einer unbelasteten Kontrollgruppe bestehend aus 45 Blutspendern gegenuebergestellt. Als Parameter fuer ein biologisches Monitoring wurde die Blut-Toluolkonzentration und die Exkretion von Hippursaeure verwendet. Die Blut-Toluolkonzentration lag im Mittel bei 830 {mu}g/l. Der Mittelwert der Hippursaeure im Urin der unbelasteten Gruppe lag bei 0,405 mg/mg Kreatinin und der belasteten Gruppe bei 1,938 mg/mg Kreatinin. Die Hippursaeureausscheidung war hoch signifikant mit den Werten der ORSA-Roehrchen fuer die Luft-Toluolkonzentration korreliert (p=0,000). Erhebliche individuelle Abweichungen im Toluol-Metabolismus wurden deutlich und anhand von Rauch- und Trinkgewohnheiten diskutiert. (orig.)

  14. Immune defence against HIV-1 infection in HIV-1-exposed seronegative persons.

    Science.gov (United States)

    Schmechel, S C; Russell, N; Hladik, F; Lang, J; Wilson, A; Ha, R; Desbien, A; McElrath, M J

    2001-11-01

    Rare individuals who are repeatedly exposed to HIV-1 through unprotected sexual contact fail to acquire HIV-1 infection. These persons represent a unique study population to evaluate mechanisms by which HIV-1 replication is either prevented or controlled. We followed longitudinally a group of healthy HIV-1 seronegative persons each reporting repeated high-risk sexual activities with their HIV-1-infected partner at enrollment. The volunteers were primarily (90%) male homosexuals, maintaining high risk activities with their known infected partner (45%) or multiple other partners (61%). We evaluated the quantity and specificity of HIV-1-specific T cells in 31 exposed seronegatives (ES) using a IFN-gamma ELISPOT assay to enumerate T cells recognizing epitopes within HIV-1 Env, Gag, Pol and Nef. PBMC from only three of the 31 volunteers demonstrated ex vivo HIV-1-specific IFN-gamma secretion, in contrast to nearly 30% exhibiting cytolytic responses in previous studies. These findings suggest that if T cell responses in ES are induced by HIV-1 exposure, the frequency is at low levels in most of them, and below the level of detection using the ELISPOT assay. Alternative approaches to improve the sensitivity of detection may include use of dendritic cells as antigen-presenting cells in the ex vivo assay and more careful definition of the risk behavior and extent of HIV-1 exposure in conjunction with the evaluation of T cell responses.

  15. Molecular markers for assessment of radiation-induced oxidant stress of occupationally exposed persons

    International Nuclear Information System (INIS)

    Stankova, K.; Zaharieva, E.; Aneva, N.; Kazarska, O.; Boteva, R.

    2013-01-01

    Full text: Introduction: The biological effects of ionizing radiation (IR) are mainly due to high creativity, oxygen - containing free radicals and molecules known as Reactive Oxygen Species (ROS). After irradiation the cells accumulate ROS, which may induce destructive changes in all cell structures and macromolecules (membranes, DNA, RNA , proteins and enzymes) and result in abnormalities on cell and tissue level. The effects of ROS are particularly important in chronic oxidative stress induced by prolonged occupational exposure that can permanently disrupt cellular redox homeostasis, which increase the risk of oncogenic, neurodegenerative, cardiovascular and other diseases. This requires the study of the antioxidant status of the Kozloduy NPP personnel who are professionally exposed to low dose irradiation. Materials and methods: As an antioxidant status markers, changes in the levels of the ROS and the electrochemical potential at mitochondrial lymphocytes (both before and after their additional in vitro exposure to 3 Gy), as well as the antioxidant activity of blood plasma are analyzed. The study was conducted with spectral methods and includes 40 professionally exposed people from the Kozloduy NPP (mean age 44.3, and radiation exposure from 0,1 to 257,9 mSv) and 20 unexposed controls (mean age 46.5 years). Results: Statistical analysis of the data shows that chronic exposure to low doses IR as a result of occupation exposure does not lead to significant changes in the levels of the ROS, the antioxidant activity of plasma and mitochondrial electrochemical potential. More significant impact on these indicators proves the age of the respondents, which is explained by a decrease in the activity of the cellular reparative and antioxidant systems induced by the natural processes of aging. Results for occupational exposure and non-exposure persons were heterogeneous due to the individual radio sensitivity of the persons included in biomonitoring. Conclusion

  16. Monitoring occupational exposure to ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Button, J.B.C. [Radiation Safety Consultancy, Engadine, NSW (Australia)

    1997-12-31

    A brief overview is presented of methods of monitoring occupational exposure to ionizing radiation together with reasons for such monitoring and maintaining dose histories of radiation occupationally exposed persons. The various Australian providers of external radiation monitoring services and the types of dosemeters they supply are briefly described together with some monitoring results. Biological monitoring methods, are used to determine internal radiation dose. Whole body monitors, used for this purpose are available at Australian Radiation Lab., ANSTO and a few hospitals. Brief mention is made of the Australian National Radiation Dose Register and its objectives. 8 refs., 9 tabs.

  17. Own experiences in genetic counselling of radiation exposed persons

    International Nuclear Information System (INIS)

    Laude, G.; Bruening, L.

    1995-01-01

    An outline is given of genetic counselling provided to 46 radiation-exposed persons during the period from 1978 to 1994. The radiation exposure had, in most cases, been due to radiation-therapeutic measures (n=22). To a low extent, counselling was carried out because of fear of genetic consequences of the Chernobyl reactor accident (n=11), preceding radiation exposure from X-ray (n=9) and nuclear diagnosis (n=1) as well as occupation radiation exposure (n=3). During counselling, information was given on the genetic risk to be expected, taking into consideration the risk factor that is valid at present and the malformation doubling dose. After performance of radiation therapy, an avoidance of conception for 2 years has been recommended. After termination of this period, in the case of an urgent wish of having children, pregnancy was not discouraged if no further risk factors existed. (orig.) [de

  18. Application of ubiquitous computing in personal health monitoring systems.

    Science.gov (United States)

    Kunze, C; Grossmann, U; Stork, W; Müller-Glaser, K D

    2002-01-01

    A possibility to significantly reduce the costs of public health systems is to increasingly use information technology. The Laboratory for Information Processing Technology (ITIV) at the University of Karlsruhe is developing a personal health monitoring system, which should improve health care and at the same time reduce costs by combining micro-technological smart sensors with personalized, mobile computing systems. In this paper we present how ubiquitous computing theory can be applied in the health-care domain.

  19. The Role of Personality in a Regular Cognitive Monitoring Program.

    Science.gov (United States)

    Sadeq, Nasreen A; Valdes, Elise G; Harrison Bush, Aryn L; Andel, Ross

    2018-02-20

    This study examines the role of personality in cognitive performance, adherence, and satisfaction with regular cognitive self-monitoring. One hundred fifty-seven cognitively healthy older adults, age 55+, completed the 44-item Big-Five Inventory and were subsequently engaged in online monthly cognitive monitoring using the Cogstate Brief Battery for up to 35 months (M=14 mo, SD=7 mo). The test measures speed and accuracy in reaction time, visual learning, and working memory tasks. Neuroticism, although not related to cognitive performance overall (P>0.05), was related to a greater increase in accuracy (estimate=0.07, P=0.04) and speed (estimate=-0.09, P=0.03) on One Card Learning. Greater conscientiousness was related to faster overall speed on Detection (estimate=-1.62, P=0.02) and a significant rate of improvement in speed on One Card Learning (estimate=-0.10, Pconscientiousness were observed. Participants volunteering for regular cognitive monitoring may be quite uniform in terms of personality traits, with personality traits playing a relatively minor role in adherence and satisfaction. The more neurotic may exhibit better accuracy and improve in speed with time, whereas the more conscientious may perform faster overall and improve in speed on some tasks, but the effects appear small.

  20. Accuracy and practicality of a portable ozone monitor for personal exposure estimates

    Science.gov (United States)

    Sagona, Jessica A.; Weisel, Clifford P.; Meng, Qingyu

    2018-02-01

    Accurate measurements of personal exposure to atmospheric pollutants such as ozone are important for understanding health risks. We tested a new personal ozone monitor (POM; 2B Technologies) for accuracy, precision, and ease of use. The POM's measurements were compared to simultaneous ozone measurements from a 2B Model 205 monitor and a ThermoScientific 49i monitor, and multiple POMs were placed side-by-side to check precision. Tests were undertaken in a controlled environmental facility, outdoors, and in a private residence. Additionally, ten volunteers wore a POM for five days and answered a questionnaire about its ease of use. The POM measured ozone accurately compared to the 49i ozone monitor, with average relative differences of less than 8%. In the controlled environment tests, the POM's ozone measurements did not change in the presence of additional atmospheric constituents with similar absorption lines to ozone, though there may have been a small decrease in precision and accuracy. Precision between POMs varied by environment (r2 = 0.98 outdoors; r2 = 0.3 to 0.9 in controlled lab conditions). Volunteers reported that the POM was reasonably comfortable to wear, although all reported that they felt that it was too noisy. Overall, the POM is a viable option for personal ozone monitoring.

  1. Personal monitoring in complex geometry of photon exposures

    International Nuclear Information System (INIS)

    Cunha, P.G.; Drexler, G.

    1996-01-01

    The ratio (effective dose, E) / (personal dose equivalent, Hp(10) ) was calculated for some scenarios set in broad parallel photon beams. Worker's irradiation condition are shown in which the number and locations of the individual monitor have to be carefully determined in order to avoid that the value of effective dose is underestimated

  2. Human biological monitoring of occupational genotoxic exposures

    DEFF Research Database (Denmark)

    Knudsen, Lisbeth E.; Sorsa, M

    1993-01-01

    Human biological monitoring is a valuable tool for exposure assessment in groups of persons occupationally exposed to genotoxic agents. If the monitoring activity covers genetic material the term genetic monitoring is used. The methods used for genetic monitoring are either substance specific, e......) occupational exposure limit value of styrene in ambient air. The consideration of ethical issues in human genetic monitoring is an important but often overlooked aspect. This includes the scientific and preventional relevance of performing a test on individuals, pre- and post study information of donors...

  3. Hearing Loss in Persons Exposed and not Exposed to Occupational Noise.

    Science.gov (United States)

    Kovalova, Martina; Mrazkova, Eva; Sachova, Petra; Vojkovska, Kristyna; Tomaskova, Hana; Janoutova, Jana; Janout, Vladimir

    2016-04-01

    This study aimed to compare hearing loss in individuals at risk and those not at risk for occupational noise and to compare working loss by gender. The analysis used data from a current Czech Ministry of Health grant project called Epidemiological and Genetic Study of the Frequency of Hearing Loss (2011 to 2015; NT12246-5/2011). The analyzed sample comprised 4988 participants. Hearing was tested using pure-tone threshold audiometry, tympanometry, and measurement of the stapedius reflex. Females at risk and those not at risk for occupational noise who were younger than 44 years and older than 75 years were found to have no statistically significant differences at any pure-tone threshold audiometry frequency. In females aged 45 to 74 years, statistically significant differences were found. In males, hearing loss was observed as early as 18 years of age. When comparing males and females at no risk for occupational noise, there were no statistically significant differences at any of the frequencies in those younger than 29 years. In females aged 30 years or older, statistically significant differences were observed at various frequencies in all age groups. When comparing males and females at risk for occupational noise, statistically significant differences were more frequent than in employees not exposed to noise. Hearing loss in females does not significantly vary depending on occupational exposure. The opposite is true for males. However, the maximum differences in mean levels did not exceed 10 dB. It is therefore clear that noise is a preventable factor, and the use of personal protective equipment is warranted.

  4. Localizing the HL7 Personal Health Monitoring Record for Danish Telemedicine

    DEFF Research Database (Denmark)

    Christensen, Henrik Bærbak

    2014-01-01

    Telemedicine holds a promise of lowering cost in health care and improving the life quality of chronic ill patients by allowing monitoring in the home. The Personal Health Monitoring Record (PHMR) is an international HL7 standard data format for encoding measurements made by devices in the home...

  5. Parental Substance Abuse As an Early Traumatic Event. Preliminary Findings on Neuropsychological and Personality Functioning in Young Drug Addicts Exposed to Drugs Early.

    Science.gov (United States)

    Parolin, Micol; Simonelli, Alessandra; Mapelli, Daniela; Sacco, Marianna; Cristofalo, Patrizia

    2016-01-01

    Parental substance use is a major risk factor for child development, heightening the risk of drug problems in adolescence and young adulthood, and exposing offspring to several types of traumatic events. First, prenatal drug exposure can be considered a form of trauma itself, with subtle but long-lasting sequelae at the neuro-behavioral level. Second, parents' addiction often entails a childrearing environment characterized by poor parenting skills, disadvantaged contexts and adverse childhood experiences (ACEs), leading to dysfunctional outcomes. Young adults born from/raised by parents with drug problems and diagnosed with a Substance Used Disorder (SUD) themselves might display a particularly severe condition in terms of cognitive deficits and impaired personality function. This preliminary study aims to investigate the role of early exposure to drugs as a traumatic event, capable of affecting the psychological status of young drug addicts. In particular, it intends to examine the neuropsychological functioning and personality profile of young adults with severe SUDs who were exposed to drugs early in their family context. The research involved three groups, each consisting of 15 young adults (aged 18-24): a group of inpatients diagnosed with SUDs and exposed to drugs early, a comparison group of non-exposed inpatients and a group of non-exposed youth without SUDs. A neuropsychological battery (Esame Neuropsicologico Breve-2), an assessment procedure for personality disorders (Shedler-Westen Assessment Procedure-200) and the Symptom CheckList-90-Revised were administered. According to present preliminary results, young drug addicts exposed to drugs during their developmental age were characterized by elevated rates of neuropsychological impairments, especially at the expense of attentive and executive functions (EF); personality disorders were also common but did not differentiate them from non-exposed youth with SUDs. Alternative multi-focused prevention and

  6. Persons occupationally exposed to radiation in the Federal Land Niedersachen

    International Nuclear Information System (INIS)

    Ruschkowski, E. von; Kalmbach, U.

    1984-01-01

    The results of the physical radiation protection control according to section 62 of the ordinance on radiation protection (StrlSchVO) or section 40 of the roentgen ordinance (ROeV) for the report year 1982 are presented in table form. They show persons and plants under the legal obligation of being monitored events of excess radiation exposure, frequency distribution of the annual doses, survey of incorporation measurements and results of the first and following medical checks according to section 42 ROeV and section 71 StrlSchVO. In the year of report, no personnel contaminations occurred. (HSCH) [de

  7. Individual differences in error monitoring in healthy adults: psychological symptoms and antisocial personality characteristics.

    Science.gov (United States)

    Chang, Wen-Pin; Davies, Patricia L; Gavin, William J

    2010-10-01

    Recent studies have investigated the relationship between psychological symptoms and personality traits and error monitoring measured by error-related negativity (ERN) and error positivity (Pe) event-related potential (ERP) components, yet there remains a paucity of studies examining the collective simultaneous effects of psychological symptoms and personality traits on error monitoring. This present study, therefore, examined whether measures of hyperactivity-impulsivity, depression, anxiety and antisocial personality characteristics could collectively account for significant interindividual variability of both ERN and Pe amplitudes, in 29 healthy adults with no known disorders, ages 18-30 years. The bivariate zero-order correlation analyses found that only the anxiety measure was significantly related to both ERN and Pe amplitudes. However, multiple regression analyses that included all four characteristic measures while controlling for number of segments in the ERP average revealed that both depression and antisocial personality characteristics were significant predictors for the ERN amplitudes whereas antisocial personality was the only significant predictor for the Pe amplitude. These findings suggest that psychological symptoms and personality traits are associated with individual variations in error monitoring in healthy adults, and future studies should consider these variables when comparing group difference in error monitoring between adults with and without disabilities. © 2010 The Authors. European Journal of Neuroscience © 2010 Federation of European Neuroscience Societies and Blackwell Publishing Ltd.

  8. Medical observation and evaluation of persons accidentally exposed to 241Am-Be neutron source

    International Nuclear Information System (INIS)

    Li Jinbang; Bai Yushu; Zhang Jiayu

    1986-01-01

    A radiation accident caused by an 241 Am-Be source is reported. A boy, 17 years old, brought an 241 Am-Be source of 120 mCi to home and drilled a hole in it. In all 10 persons were irradiated with varying doses and were contaminated to different extent. The maximum dose of external exposure was 121 x 10 -3 Gy and the maximum concentration of urinary 241 Am was 2.8 dpm. The exposed persons felt dizziness, palpitation and myalgia at the early stage. At that time there were slight increase in leucocyte counts, presence of heterogeneous lymphocytes and increase in frequency of leucocyte spinous process. Follow-up study for one and a half years on general health condition, hematological changes, immune function (T-and B-lymphocytes) and crystalline lens alterations revealed no significant differences between the irradiated and the non-irradiated persons, but the frequencies of all types of chromosome aberrations in the irradiated group were significantly higher than those in the control group

  9. Comparative cytogenetic analysis of chromosomal aberrations and premature centromere division in persons exposed to radionuclides

    International Nuclear Information System (INIS)

    Jovicic, D.; Rakic, B.; Vukov, T.; Pajic, J.; Milacic, S.; Kovacevic, R.; Stevanovic, M.; Drakulic, D.; Bukvic, N.

    2009-01-01

    The aim of the research was to determine the presence of correlation between the frequency of premature centromere division (PCD) and chromosomal aberrations (CA) in metaphases in persons professionally exposed to radionuclides. Biological dosimetry was performed by conventional cytogenetic technique. The presence of PCD was confirmed by Fluorescent in situ hybridization (FISH). The L1.84 probe (specific for centromeric region of chromosome 18) was used. The analysis included 50 subjects employed in the Clinical Center of Serbia (C) (the average age of 45.24 ± 1.18 and the average exposition time 17.96 ± 1.15) and 40 subjects in control group (K) (the average age of 44.40 ± 0.98 and the average years of employment 19.67 ± 0.98 years) which were not exposed to genotoxic agents in their workplaces. The results showed that frequencies of CA and PCD were statistically significantly higher in subjects exposed to radionuclides than in the control group (Mann-Whitney U test, P [sr

  10. Individual monitoring of external exposure in terms of personal dose equivalent, Hp(d)

    International Nuclear Information System (INIS)

    Fantuzzi, E.

    2001-01-01

    The institute for Radiation Protection of ENEA - Bologna has organised a one day-workshop on the subject: Individual monitoring of external exposure in terms of personal dose equivalent, H p (d). The aim of the workshop was the discussion of the new implications and modifications to be expected in the routine individual monitoring of external radiation, due to the issue of the Decree 241/00 (G.U. 31/8/2000) in charge since 01/01/2001. The decree set up in Italian law the standards contained in the European Directive EURATOM 96/29-Basic Standards for the Protection of Health of Workers and the General Public against Dangers arising from Ionizing Radiation. Among others, the definition of the operational quantities for external radiation for personal and environmental monitoring, H p (d) e H * (d) respectively as defined by ICRU (International Commission for Radiation Units and Measurements), requires to update the methods of measurements and calibration of the personal dosemeters and environmental monitors. This report collects the papers presented at the workshop dealing with the Personal Dose Equivalent, H p (d), the conversion coefficients, H p (d)/K a e H p (d)/ , obtained through Monte Carlo calculations published by ICRU and ICRP (International Commission for Radiation Protection), the new calibration procedures and the practical implication in the routine of individual monitoring in terms of H p (d). Eventually, in the last chapter, the answers to Frequently Asked Questions (FAQ) are briefly reported [it

  11. High-frequency Audiometry Hearing on Monitoring of Individuals Exposed to Occupational Noise: A Systematic Review.

    Science.gov (United States)

    Antonioli, Cleonice Aparecida Silva; Momensohn-Santos, Teresa Maria; Benaglia, Tatiana Aparecida Silva

    2016-07-01

    The literature reports on high-frequency audiometry as one of the exams used on hearing monitoring of individuals exposed to high sound pressure in their work environment, due to the method́s greater sensitivity in early identification of hearing loss caused by noise. The frequencies that compose the exam are generally between 9 KHz and 20KHz, depending on the equipment. This study aims to perform a retrospective and secondary systematic revision of publications on high-frequency audiometry on hearing monitoring of individuals exposed to occupational noise. This systematic revision followed the methodology proposed in the Cochrane Handbook, focusing on the question: "Is High-frequency Audiometry more sensitive than Conventional Audiometry in the screening of early hearing loss individuals exposed to occupational noise?" The search was based on PubMed data, Base, Web of Science (Capes), Biblioteca Virtual em Saúde (BVS), and in the references cited in identified and selected articles. The search resulted in 6059 articles in total. Of these, only six studies were compatible with the criteria proposed in this study. The performed meta-analysis does not definitively answer the study's proposed question. It indicates that the 16 KHz high frequency audiometry (HFA) frequency is sensitive in early identification of hearing loss in the control group (medium difference (MD = 8.33)), as well as the 4 KHz frequency (CA), this one being a little less expressive (MD = 5.72). Thus, others studies are necessary to confirm the HFA importance for the early screening of hearing loss on individuals exposed to noise at the workplace.

  12. CMX - A Generic Solution to Expose Monitoring Metrics in C and C++ Applications

    CERN Document Server

    Ehm, F; Gorgogianni, G M; Jensen, S; Jurcso, P

    2014-01-01

    CERN’s Accelerator Control System is built upon a large number of C, C++ and Java services that are required for daily operation of the accelerator complex. The knowledge of the internal state of these processes is essential for problem diagnostic as well as for constant monitoring for pre-failure recognition. The CMX library follows similar principles as JMX (Java Management Extensions) and provides similar monitoring capabilities for C and C++ applications. It allows registering and exposing runtime information as simple counters, floating point numbers or character data. This can be subsequently used by external diagnostics tools for checking thresholds, sending alerts or trending. CMX uses shared memory to ensure non-blocking read/update actions, which is an important requirement in real-time processes. This paper introduces the topic of monitoring C/C++ applications and presents CMX as a building block to achieve this goal.

  13. Protection of persons occupationally exposed to radiation and of patients

    International Nuclear Information System (INIS)

    Stieve, F.E.

    1976-01-01

    The experiences of the last ten years have shown that the measures of the First Radiation Protection Ordinance generally proved to be sufficient for the protection of the employed or of the patients. They had to be amended in so far as the exposure to radiation for those occupationally exposed can be reduced. This results in changes to the regulations so that certain groups of persons can also be effectively controlled. The recognition that medical supervision for radiation protection reasons is reasonable only if exposure has occurred should be additionally utilized in the regulations if the Euratom standards make this possible. The protection of patients attains some new rules which can be derived from handling and from therapeutical use. In this case too experience resulted in a more reasonable application of ionizing radiation and radioactive materials than was expected when the First Radiation Protection Ordinance was issued. (orig.) [de

  14. Development and implementation of tools for self-monitoring of staff exposed to 131I in nuclear medicine centres of Chile

    International Nuclear Information System (INIS)

    Diaz-Londono, G.; Garcia, M.; Astudillo, R.; Hermosilla, A.

    2017-01-01

    Currently in Chile, there are about 42 nuclear medicine centres that mainly use 99m Tc and 131 I in diagnostic and therapeutic procedures. Therefore, staff performs various tasks that increase the risk of internal incorporation and the need to implement routine monitoring programmes. This article shows tools for self-monitoring of staff who exposed to 131 I from measurements in thyroid and urine samples, using the gamma cameras of Nuclear Medicine Units. Then, the calibration factors of gamma cameras of participating units were determined, and a one-worker dose was calculated due to internal incorporation, using an Excel spreadsheet for self-monitoring. The worker who handles 131 I in one of the studied units was monitored for 6 months. The goal of this study is to implement a routine self-monitoring programme for the estimation of committed effective dose of staff exposed to 131 I using gamma cameras in Nuclear Medicine Units of clinical centres in Chile. (authors)

  15. High-frequency Audiometry Hearing on Monitoring of Individuals Exposed to Occupational Noise: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Antonioli, Cleonice Aparecida Silva

    2015-12-01

    Full Text Available Introduction The literature reports on high-frequency audiometry as one of the exams used on hearing monitoring of individuals exposed to high sound pressure in their work environment, due to the method́s greater sensitivity in early identification of hearing loss caused by noise. The frequencies that compose the exam are generally between 9 KHz and 20KHz, depending on the equipment. Objective This study aims to perform a retrospective and secondary systematic revision of publications on high-frequency audiometry on hearing monitoring of individuals exposed to occupational noise. Data Synthesis This systematic revision followed the methodology proposed in the Cochrane Handbook, focusing on the question: “Is High-frequency Audiometry more sensitive than Conventional Audiometry in the screening of early hearing loss individuals exposed to occupational noise?” The search was based on PubMed data, Base, Web of Science (Capes, Biblioteca Virtual em Saúde (BVS, and in the references cited in identified and selected articles. The search resulted in 6059 articles in total. Of these, only six studies were compatible with the criteria proposed in this study. Conclusion The performed meta-analysis does not definitively answer the study's proposed question. It indicates that the 16 KHz high frequency audiometry (HFA frequency is sensitive in early identification of hearing loss in the control group (medium difference (MD = 8.33, as well as the 4 KHz frequency (CA, this one being a little less expressive (MD = 5.72. Thus, others studies are necessary to confirm the HFA importance for the early screening of hearing loss on individuals exposed to noise at the workplace.

  16. Personal dose monitoring in hospitals: Global assessment, critical applications and future needs

    International Nuclear Information System (INIS)

    Covens, P.; Berus, D.; Buls, N.; Clerinx, P.; Vanhavere, F.

    2007-01-01

    It is known that medical applications using ionising radiation are wide spread and still increasing. Physicians, technicians, nurses and others constitute the largest group of workers occupationally exposed to man-made sources of radiation. Many hospital workers are consequently subjected to routine monitoring of professional radiation exposures. in the university hospital, UZ Brussel, 600 out of 4000 staff members are daily monitored for external radiation exposures. The most obvious applications of ionising radiation are diagnostic radiology, diagnostic or therapeutic use of radionuclides in nuclear medicine and external radiation therapy or brachytherapy in radiotherapy departments. Other important applications also include various procedures in interventional radiology (IR), in vitro biomedical research and radiopharmaceutical production around cyclotrons. Besides the fact that many of the staff members, involved in these applications, are not measurably exposed, detailed studies were carried out at workplaces where routine dose monitoring encounters difficulties and for some applications where relatively high occupational exposures can be found. most of the studies are concentrated around nuclear medicine applications and IR. They contain assessments of both effective dose and doses at different parts of the body. The results contribute to better characterisation of the different workplaces in a way that critical applications can be identified. Moreover, conclusions point out future needs for practical routine dose monitoring and optimisation of radiation protection. (authors)

  17. Contribution of various microenvironments to the daily personal exposure to ultrafine particles: Personal monitoring coupled with GPS tracking

    Science.gov (United States)

    Bekö, Gabriel; Kjeldsen, Birthe Uldahl; Olsen, Yulia; Schipperijn, Jasper; Wierzbicka, Aneta; Karottki, Dorina Gabriela; Toftum, Jørn; Loft, Steffen; Clausen, Geo

    2015-06-01

    Exposure to ultrafine particles (UFP) may have adverse health effects. Central monitoring stations do not represent the personal exposure to UFP accurately. Few studies have previously focused on personal exposure to UFP. Sixty non-smoking residents living in Copenhagen, Denmark were asked to carry a backpack equipped with a portable monitor, continuously recording particle number concentrations (PN), in order to measure the real-time individual exposure over a period of ˜48 h. A GPS logger was carried along with the particle monitor and allowed us to estimate the contribution of UFP exposure occurring in various microenvironments (residence, during active and passive transport, other indoor and outdoor environments) to the total daily exposure. On average, the fractional contribution of each microenvironment to the daily integrated personal exposure roughly corresponded to the fractions of the day the subjects spent in each microenvironment. The home environment accounted for 50% of the daily personal exposure. Indoor environments other than home or vehicles contributed with ˜40%. The highest median UFP concentration was obtained during passive transport (vehicles). However, being in transit or outdoors contributed 5% or less to the daily exposure. Additionally, the subjects recorded in a diary the periods when they were at home. With this approach, 66% of the total daily exposure was attributable to the home environment. The subjects spent 28% more time at home according to the diary, compared to the GPS. These results may indicate limitations of using diaries, but also possible inaccuracy and miss-classification in the GPS data.

  18. The current situation of personal dose monitoring in Chinese medicine radiation and undamaged detection

    International Nuclear Information System (INIS)

    Zhang Liangan; Zhang Wenyi; Yuan Shuyu; Song Shijun; Chang Hexin; Sun Kai

    1993-01-01

    The situation of personal dose monitoring in γ(X) external exposure in China is mainly outlined. Thermoluminescent dosimetry (TLD) was adopted for personal dose measurement of the radiation workers. The computer software and data base for the work have been developed and applied. National intercomparison of TLD, monitoring control of personal dose monitoring in field, and technical training were carried out for quality control. In China, the dominant occupational exposures is X-ray diagnosis and it increases year by year, the highest values is about 22.6%. The highest values of annual collective dose and annual average of individual dose (AAID) are 272.8 man·Sv and 3.21 mSv respectively. This work shows that the fraction of the population receiving high dose is decreased with time rapidly. The situation for whole occupational exposures is also described. (3 tabs.)

  19. Development of a high-resolution apparatus to monitor physiological state of a person undergoing extreme conditions

    Directory of Open Access Journals (Sweden)

    Kodermyatov Radik

    2016-01-01

    Full Text Available The present research has shown that ECG recordings and parameters of the body functional state are crucial for all kinds of the astronaut pre-flight preparations (centrifuge, thermal chamber, pressure chamber, pressure chamber with special equipment. It is, therefore, important to develop methods and tools for early detection of the preclinical forms of the functional state disorders in patients undergoing high-intensity loads of mixed character. The method based on the hardware-software compleх (HSC with nanosensors of high resolution has been proposed to measure the electrophysiological characteristics and bioelectrical impedance of the body tissues directly exposed to loading. The hardware-software compleх is subjected to clinical trials in Tomsk Research Institute for Cardiology. The obtained results show that the use of nanosensors of high resolution in the HSC without standard filters allows elimination of the power-line interference in ECG recordings. Monitoring of the tissue bioimpedance parameters under test loads enables the detection of preclinical (latent forms of various diseases. After clinical trials in Tomsk Institute for Cardiology the developed apparatus will be proposed for in-depth study of the cardiovascular system and the functional state of the body of astronauts and other persons exposed to extreme loads.

  20. Personality and Major Depression among Directly Exposed Survivors of the Oklahoma City Bombing

    Directory of Open Access Journals (Sweden)

    Carol S. North

    2012-01-01

    Full Text Available Background. Few disaster studies have specifically examined personality and resilience in association with disaster exposure, posttraumatic stress disorder (PTSD, and major depression. Methods. 151 directly-exposed survivors of the Oklahoma City bombing randomly selected from a bombing survivor registry completed PTSD, major depression, and personality assessments using the Diagnostic Interview Schedule for DSM-IV and the Temperament and Character Inventory, respectively. Results. The most prevalent postdisaster psychiatric disorder was bombing-related PTSD (32%; major depression was second in prevalence (21%. Bombing-related PTSD was associated with the combination of low self-directedness and low cooperativeness and also with high self-transcendence and high harm avoidance in most configurations. Postdisaster major depression was significantly more prevalent among those with (56% than without (5% bombing-related PTSD (P<.001 and those with (72% than without (14% predisaster major depression (P<.001. Incident major depression was not associated with the combination of low self-directedness and low cooperativeness. Conclusions. Personality features can distinguish resilience to a specific life-threatening stressor from general indicators of well-being. Unlike bombing-related PTSD, major depression was not a robust marker of low resilience. Development and validation of measures of resilience should utilize well-defined diagnoses whenever possible, rather than relying on nonspecific measures of psychological distress.

  1. Early rehabilitation of occupationally exposed persons in the Staatliches Amt fuer Atomsicherheit und Strahlenschutz der DDR. 2

    International Nuclear Information System (INIS)

    Arndt, D.; Lenz, U.; Rothe, E.; Schuettmann, W.

    1977-02-01

    Within the frame of a 3-year pilot study relating to the problem of early rehabilitation of occupationally exposed persons, 178 patients with 189 cases of illness were attended dermatologically and/or internally. Due to the high rate of improvement (67.7 %) the radiation fitness of the patients could be recovered or preserved in several cases, this being of great national economic benefit because of the high level of qualification to be found in this category of persons. The described prophylactic method of early rehabilitation is strongly recommended to the responsible medical officers as a means of optimizing their supervision activity. (author)

  2. A personal computer based console monitor for a TRIGA reactor

    International Nuclear Information System (INIS)

    Rieke, Phillip E.; Hood, William E.; Razvi, Junaid

    1990-01-01

    Numerous improvements have been made to the Mark F facility to provide a minimum reactor down time, giving a high reactor availability. A program was undertaken to enhance the monitoring capabilities of the instrumentation and control system on this reactor. To that end, a personal computer based console monitoring system has been developed, installed in the control room and is operational to provide real-time monitoring and display of a variety of reactor operating parameters. This system is based on commercially available hardware and an applications software package developed internally at the GA facility. It has (a) assisted the operator in controlling reactor parameters to maintain the high degree of power stability required during extended runs with thermionic devices in-core, and (b) provided data trending and archiving capabilities on all monitored channels to allow a post-mortem analysis to be performed on any of the monitored parameters

  3. Person × Environment Interactions on Adolescent Delinquency: Sensation Seeking, Peer Deviance and Parental Monitoring.

    Science.gov (United States)

    Mann, Frank D; Kretsch, Natalie; Tackett, Jennifer L; Harden, K Paige; Tucker-Drob, Elliot M

    2015-04-01

    Sensation seeking is a personality trait that is robustly correlated with delinquent behavior in adolescence. The current study tested specific contextual factors hypothesized to facilitate, exacerbate or attenuate this risk factor for adolescent delinquency. Individual differences in sensation seeking, peer deviance, parental monitoring and self-reported delinquent behavior were assessed in a sample of 470 adolescents. Peer deviance partially mediated the effects of sensation seeking and parental monitoring on adolescent delinquency. We also found evidence for a three-way interaction between sensation seeking, peer deviance and parental monitoring, such that the highest rates of delinquency occurred from the concurrence of high sensation seeking, high peer deviance, and low levels of parental monitoring. Results highlight the importance of considering peer- and family-level processes when evaluating personality risk and problematic adolescent behavior.

  4. Contribution to the monitoring of workers exposed to non-transferable uranium compounds

    International Nuclear Information System (INIS)

    Camarasa, J.; Chalabreysse, J.

    1980-01-01

    After a short review of the present knowledge on uranium (metabolism, toxicity, principles of radiotoxicological monitoring), the authors' experience in the surveillance of workers exposed to natural non-transferable uranium compounds (oxides, tetrafluorides) is presented. When setting up urinary controls in a workers' population, a number of difficulties were met in the way of collecting urine samples, obtaining samples free of exogen contribution, interpreting results. The working environment was also studied: three types of pollution measurements were carried out: on the atmosphere at fixed places by measuring the radioactivity of air sample, on work-places and workers by chemical analysis and counting of uranium. Original graphs on work-place monitoring are up-dated regularly. Workers' surveillance by urinary and working condition controls are now well codified. However, further studies will be carried out on man, on working atmospheres, and on the substances handled. The surveillance will then cover working conditions from all points of view [fr

  5. Personal monitoring and assessment of doses received by radiation workers

    International Nuclear Information System (INIS)

    Swindon, T.N.; Morris, N.D.

    1981-12-01

    The Personal Radiation Monitoring Service operated by the Australian Radiation Laboratory is outlined and the types of monitors used for assessment of doses received by radiation workers are described. The distribution of doses received by radiation workers in different occupational categories is determined. From these distributions, the average doses received have been assessed and the maximum likely additional increase in cancer deaths in Australia as a result of occupational exposure estimated. This increase is shown to be very small. There is, however, a considerable spread of doses received by individuals within occupational groups

  6. Automatic data acquisition system of environmental radiation monitor with a personal computer

    International Nuclear Information System (INIS)

    Ohkubo, Tohru; Nakamura, Takashi.

    1984-05-01

    The automatic data acquisition system of environmental radiation monitor was developed in a low price by using a PET personal computer. The count pulses from eight monitors settled at four site boundaries were transmitted to a radiation control room by a signal transmission device and analyzed by the computer via 12 channel scaler and PET-CAMAC Interface for graphic display and printing. (author)

  7. Personalized Health Monitoring System for Managing Well-Being in Rural Areas.

    Science.gov (United States)

    Nedungadi, Prema; Jayakumar, Akshay; Raman, Raghu

    2017-12-14

    Rural India lacks easy access to health practitioners and medical centers, depending instead on community health workers. In these areas, common ailments that are easy to manage with medicines, often lead to medical escalations and even fatalities due to lack of awareness and delayed diagnosis. The introduction of wearable health devices has made it easier to monitor health conditions and to connect doctors and patients in urban areas. However, existing initiatives have not succeeded in providing adequate health monitoring to rural and low-literate patients, as current methods are expensive, require consistent connectivity and expect literate users. Our design considerations address these concerns by providing low-cost medical devices connected to a low-cost health platform, along with personalized guidance based on patient physiological parameters in local languages, and alerts to medical practitioners in case of emergencies. This patient-centric integrated healthcare system is designed to manage the overall health of villagers with real-time health monitoring of patients, to offer guidance on preventive care, and to increase health awareness and self-monitoring at an affordable price. This personalized health monitoring system addresses the health-related needs in remote and rural areas by (1) empowering health workers in monitoring of basic health conditions for rural patients in order to prevent escalations, (2) personalized feedback regarding nutrition, exercise, diet, preventive Ayurveda care and yoga postures based on vital parameters and (3) reporting of patient data to the patient's health center with emergency alerts to doctor and patient. The system supports community health workers in the diagnostic procedure, management, and reporting of rural patients, and functions well even with only intermittent access to Internet.

  8. The Recent System of the Personal Monitoring in the Czech Republic

    International Nuclear Information System (INIS)

    Petrova, K.

    2001-01-01

    Full text: The paper is intended to provide with the overview of the recent situation concerned to the management of the personal monitoring in the Czech Republic in the context of the harmonisation process of legislation within the European Union. New legislation concerning the radiation protection, which is effective in the Czech Republic from 1997 year, arises already from the ICRP 60 and IAEA BSS and includes all new basic principles for protection of radiation workers which are established and recommended. The recent Czech legislation does not recognise the term 'outside worker' and there are no special demands for their protection. However the harmonisation of the Czech legislation with EU Directives takes in consideration also the Council Directive 90/641/EURATOM on radiation protection of outside workers. In the frame of the process of harmonisation the new terms will be implemented into the Czech Atomic Law and new radiation passports will be tested in the practice. The personal dosimetric service is identified as the practice very significant from the radiation protection point of view and shall be licensed by the State Office for Nuclear Safety (SONS). The licence application shall include the methodology of effective dose evaluation, the description of quality assurance (QA) and quality control (QC) of the service, the system of customer communication and dose recording and reporting. The results of intercomparisons are demanded. The attention is paid also to the appropriate qualification of workers performing the service. Recently three dosimetric services are approved by SONS for external monitoring (film, TLD, electronic), four services for internal monitoring (whole-body counter, thyroid and bio samples measurement), one for monitoring in uranium mines and one for dose calculation of air crew. In accordance with legislation demands, the licensee (or dosimetric service monitoring the licensee's workers) is obliged to report the personal and

  9. Smokers' Views on Personal Carbon Monoxide Monitors, Associated Apps, and Their Use: An Interview and Think-Aloud Study.

    Science.gov (United States)

    Herbeć, Aleksandra; Perski, Olga; Shahab, Lion; West, Robert

    2018-02-07

    Smartphone-based personal carbon monoxide (CO) monitors and associated apps, or "CO Smartphone Systems" (CSSs) for short, could enable smokers to independently monitor their smoking and quitting. This study explored views and preferences regarding CSSs and their use among 16 adult, UK-based smokers. First, semi-structured interviews explored participants' expectations of CSSs. Secondly, a think-aloud study identified participants' reactions to a personal CO monitor and to existing or prototype apps. Framework Analysis identified five themes: (1) General views, needs, and motivation to use CSSs; (2) Views on the personal CO monitor; (3) Practicalities of CSS use; (4) Desired features in associated apps; and (5) Factors affecting preferences for CSSs and their use. Participants had high expectations of CSSs and their potential to increase motivation. Priority app features included: easy CO testing journeys, relevant and motivating feedback, and recording of contextual data. Appearance and usability of the personal CO monitor, and accuracy and relevance of CO testing were considered important for engagement. Participants differed in their motivation to use and preferences for CSSs features and use, which might have non-trivial impact on evaluation efforts. Personal CO monitors and associated apps may be attractive tools for smokers, but making CSSs easy to use and evaluating these among different groups of smokers may be challenging.

  10. WS-010: EPR-First Responders: Personal monitoring techniques and protective clothing

    International Nuclear Information System (INIS)

    2011-01-01

    The purpose of this working session is that the participant can apply their knowledge in relation to the personal monitoring techniques and protective clothing. They have to know the use of the radiation measurement instrumentation available in each region

  11. Single-sided Nuclear Magnetic Resonance for condition monitoring of cross-linked polyethylene exposed to aggressive media

    Energy Technology Data Exchange (ETDEWEB)

    Adams, A., E-mail: Alina.Adams@itmc.rwth-aachen.de [Institut für Technische und Makromolekulare Chemie, RWTH Aachen University, Templergraben 55, 52056 Aachen (Germany); Piechatzek, A.; Schmitt, G. [Institut für Instandhaltung und Korrosionsschutztechnik gGmbH, Kalkofen 4, 58638 Iserlohn (Germany); Siegmund, G. [ExxonMobil Production Germany, Riethorst 12, 30659 Hannover (Germany)

    2015-08-05

    The potential of single-sided Nuclear Magnetic Resonance (NMR) to monitor truly non-invasive changes in polymer materials during aging under aggressive media is for the first time evaluated. For this, the NMR method is used in combination with other condition monitoring methods including mechanical measurements, mass uptake, and differential scanning calorimetry. It is validated by studying for the first time the aging kinetics of silane cross-linked polyethylene (PEX) exposed to media used in oil and gas production and transportation, including aliphatic and aromatic hydrocarbons, sulphur solvents, and corrosion inhibitors in combination with CO{sub 2} and H{sub 2}S. All investigated parameters changed, with the strongest effects detected for the NMR chain mobility and in the presence of hydrocarbons. Furthermore, a universal linear correlation curve could be established between the depression of the tensile strength and the chain mobility. This result represents a fundamental step towards establishing single-sided NMR as a new analytical tool for in situ condition monitoring of polyethylene working under sour conditions. The proposed approach can be easily extended to other polymer materials. - Highlights: • The changes in PEX exposed to sour media were quantified for the first time. • The strongest morphological changes in PEX were detected under exposure to hydrocarbon media. • The chain mobility measured truly non-destructively by single-sided NMR showed the highest sensitivity to the aging process. • A universal linear correlation curve was found between the chain mobility and the tensile strength. • Single-sided NMR was validated as a condition monitoring tool.

  12. Smokers’ Views on Personal Carbon Monoxide Monitors, Associated Apps, and Their Use: An Interview and Think-Aloud Study

    Directory of Open Access Journals (Sweden)

    Aleksandra Herbeć

    2018-02-01

    Full Text Available Smartphone-based personal carbon monoxide (CO monitors and associated apps, or “CO Smartphone Systems” (CSSs for short, could enable smokers to independently monitor their smoking and quitting. This study explored views and preferences regarding CSSs and their use among 16 adult, UK-based smokers. First, semi-structured interviews explored participants’ expectations of CSSs. Secondly, a think-aloud study identified participants’ reactions to a personal CO monitor and to existing or prototype apps. Framework Analysis identified five themes: (1 General views, needs, and motivation to use CSSs; (2 Views on the personal CO monitor; (3 Practicalities of CSS use; (4 Desired features in associated apps; and (5 Factors affecting preferences for CSSs and their use. Participants had high expectations of CSSs and their potential to increase motivation. Priority app features included: easy CO testing journeys, relevant and motivating feedback, and recording of contextual data. Appearance and usability of the personal CO monitor, and accuracy and relevance of CO testing were considered important for engagement. Participants differed in their motivation to use and preferences for CSSs features and use, which might have non-trivial impact on evaluation efforts. Personal CO monitors and associated apps may be attractive tools for smokers, but making CSSs easy to use and evaluating these among different groups of smokers may be challenging.

  13. Personal Dosimetry in UHC Sestre Milosrdnice: 10-Years Review

    International Nuclear Information System (INIS)

    Bokulic, T.; Budanec, M; Gregov, M.; Kusic, Z.; Mlinaric, M.; Mrcela, I.; Suric Mihic, M.

    2013-01-01

    Personal dose monitoring in UHC 'Sestre milosrdnice' is regulary performed for about 300 exposed workers involved in a variety of tasks with different sources of ionizing radiation. Exposed workers are required to wear personal dosimeters which are read on monthly basis and dose records are kept in the hospital. In this paper an overview of personal dosimetry data from year 2003 till 2013 is presented. Film dosimeters were used for personal dosimetry untill 2010 when the thermoluminescent (TL) dosimetry was introduced. Dosimeters are calibrated to measure personal dose equivalent H p (10). Received doses are analyzed for workers in the field of nuclear medicine, radiotherapy (external beam and brachytherapy), general diagnostic radiology and interventional radiology. Analysis of received doses in the whole period resulted with an average individual dose in nuclear medicine of 0.6 mSv/y, which decreased to 0.21 mSv/y in the last three years, caused by more precise dosimetric methods with TL dosimetry and improved conditions of radiation protection. In the same three-year period, in interventional radiology doses were 0.32 mSv/y, compared to 0.29 mSv/y obtained for a previous seven years. This was expected due to the escalation in a number of interventions and new installed equipment. There was no such difference in diagnostic radiology doses, showing that film dosimetry is suitable for x ray energies. Analysis of all the readings showed a significant influence of measurement procedures on personal dosimeter dose and also the importance of continuous monitoring of the dose records in order to improve the conditions of radiation protection and achieving the ALARA goal.(author)

  14. Development of personnel radiation monitoring program for occupationally exposed workers in Malawian Hospitals : A case study of Kamuzu Central, Bwaila and Mtengo Wa Nthenga Hospitals

    International Nuclear Information System (INIS)

    Chinangwa, Getrude

    2016-07-01

    Malawi became an IAEA member state in 2006 and developed the Atomic Energy Act and Regulations in 2011 and 2012 respectively. However, regulatory authority and personnel monitoring services have not yet been established. As such, hospitals operating radiological services in Malawi do not have personnel monitoring programme. This study aimed at developing the personnel radiation monitoring program for three hospitals in Malawi namely; Kamuzu Central Hospital, Bwaila Hospital, and Mtengo wa Nthenga Hospital. A radiation protection questionnaire was administered to the X-ray Departments involved in the study to investigate radiation protection practices in the hospitals. Dose rate measurements in the facilities were taken using survey meters and doses to individuals were recorded using personal dosimeters. The results showed that the hospitals lack radiation protection program which covers the critical issues of quality assurance and control as well as the personnel dose monitoring. Average ambient dose rate values were 0.39 μSv/hr for Mtengo wa Nthenga Hospital, 5.03 μSv/hr for Bwaila Hospital and 4μSv/hr for Kamuzu Central Hospital. Average monthly dose for workers was 0.247 mSv. The study recommends the establishment of a regulatory authority, consistent dose assessment, quality control tests and structural shielding assessment in these and probably all the diagnostic facilities in Malawi. The personnel monitoring programme developed from this study is intended to guide diagnostic facilities and personnel monitoring service providers in Malawi in tracking and reporting exposure record for their occupationally exposed workers. (au)

  15. Executive order no. 821 on dose monitoring of employees exposed to ionizing radiation

    International Nuclear Information System (INIS)

    1990-01-01

    This Order which entered into force on 1 January 1991, was made in implementation of the European Communities' Council Directive No. 80/836 Euratom amended by Directive No. 84/467 Euratom on radiation protection of 15 July 1980 and 3 September 1984 respectively. It lays down the technical standards to be observed regarding dosimetry and provides inter alia, for dosimetric control by thermoluminescent dosimetry for personal and environmental monitoring. (NEA) [fr

  16. Monitoring of activity of the persons and vehicles at the exit from the NPP Bohunice

    International Nuclear Information System (INIS)

    Dobis, L.; Kaizer, J.; Svitek, J.

    1998-01-01

    In this paper the technical description of the monitoring of activity of the persons and vehicles at the exit from the NPP Bohunice as well as the results of monitoring during last six months are described

  17. Individual Monitoring service for occupational exposure in Sudan

    International Nuclear Information System (INIS)

    Suliman, E.E.; Shaddad, I.; Medani, B.E.; Osman, M.Y.

    2005-01-01

    Full text: Individual Monitoring Service (IMS) is a dosimetry service provided by Radiation Protection Department (RPD) of Sudan Atomic Energy Commission (SAEC) to monitor about 400 occupational exposed workers all over the country. Measurements were done using thermoluminescence dosimeters (TLD). The calibration of the TLD system was performed on a phantom with application of suitable correction factors in the SSDL using Cs-137 and different qualities of x-ray energies. Personal dose equivalents Hp(10) and Hp(0.07) were evaluated by employing one individual dosimeter to be carried continuously by the occupational exposed person while at work. In this work the dose received by workers in x-ray diagnostic radiology, radiotherapy, nuclear medicine, research and industrial radiography were evaluated. Radiation doses for the years 1999, 2000, 2001, 2002 and 2003 were compared. From the results obtained, it was noticed that individual monitoring service had expanded over the last years. The average individual annual dose in different applications is less than 1 mSv/y except for the workers in industrial radiography, only 12 radiation workers (3.64 %) received doses exceeding 1 mSv and no individual approached the dose limit of 20 mSv recommended by the ICRP and set by Sudan's regulations. (author)

  18. Environmental and biological monitoring in the estimation of absorbed doses of pesticides.

    Science.gov (United States)

    Aprea, Maria Cristina

    2012-04-25

    Exposure to pesticides affects most of the population, not only persons occupationally exposed. In a context of high variability of exposure, biological monitoring is important because of the various routes by which exposure can occur and because it assesses both occupational and non-occupational exposure. The main aim of this paper was to critically compare estimates of absorbed dose measured by environmental and biological monitoring in situations in which they could both be applied. The combination of exposure measurements and biological monitoring was found to provide extremely important information on the behaviour of employees, and on the proper use and effectiveness of personal protection equipment. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  19. Personal dosimetry TLD 100 in orthopedic surgeons exposed to ionizing radiation in Bogota - Colombia

    International Nuclear Information System (INIS)

    Sierra C, B. Y.; Jimenez, Y.; Plazas, M. C.; Eslava S, J.; Groot R, H.

    2014-08-01

    Orthopedic surgeons should be considered as professionals occupationally exposed to ionizing radiation, for using C arc (fluoroscope) an equipment of X type radiation emission, during surgical procedures for imaging generation. Some health institutes, use of C arc under uncontrolled circumstances, such a lack of dosimetry control, incomplete or absence of personnel protective elements and protective measures, which in turn, lead to a high exposition to the personnel. Materials and methods. Study of double match cohort by age and gender, was conducted, in four health institutions of second and third level of attention in Bogota city. Personal dosimetry measurements with TLD-100 dosimetry crystals in both cohorts and environmental dosimetry in each of operation rooms used for orthopedic procedures, were carry out during six months of follow up. Dosimetry crystals were read in a Harshaw 4500 - Bicron equipment, in the Medical Physics Laboratory of National University of Colombia. Results. Dosimetry measurements are compatibles with those of occupationally exposed personnel 3.44 mSv/6 m CI 95% (1.66-3.99), even does not overpass ICRP recommendations, are higher as were expect at the beginning of the study. The median of effective accumulative dose in thorax is 3,4 mSv CI 95% (1,66-3,99), higher in comparison with neck value 2,7 mSv CI 95% (1,73-3,80) and hand dosimetry 1,42 mSv CI 95% (0,96-2,34). Conclusions: Orthopedic surgeons should be considered occupational exposed to ionizing radiation, who has to accomplish to the radiological protection measures, dosimetric follow up and maintenance of the used X ray equipment. It was confirm throughout this study that dosimetry shows higher levels as expected at the beginning of the study, compatible with occupationally exposed personnel. (Author)

  20. Mobile Messaging Services-Based Personal Electrocardiogram Monitoring System

    Directory of Open Access Journals (Sweden)

    Ashraf A. Tahat

    2009-01-01

    Full Text Available A mobile monitoring system utilizing Bluetooth and mobile messaging services (MMS/SMSs with low-cost hardware equipment is proposed. A proof of concept prototype has been developed and implemented to enable transmission of an Electrocardiogram (ECG signal and body temperature of a patient, which can be expanded to include other vital signs. Communication between a mobile smart-phone and the ECG and temperature acquisition apparatus is implemented using the popular personal area network standard specification Bluetooth. When utilizing MMS for transmission, the mobile phone plots the received ECG signal and displays the temperature using special application software running on the client mobile phone itself, where the plot can be captured and saved as an image before transmission. Alternatively, SMS can be selected as a transmission means, where in this scenario, dedicated application software is required at the receiving device. The experimental setup can be operated for monitoring from anywhere in the globe covered by a cellular network that offers data services.

  1. Mobile messaging services-based personal electrocardiogram monitoring system.

    Science.gov (United States)

    Tahat, Ashraf A

    2009-01-01

    A mobile monitoring system utilizing Bluetooth and mobile messaging services (MMS/SMSs) with low-cost hardware equipment is proposed. A proof of concept prototype has been developed and implemented to enable transmission of an Electrocardiogram (ECG) signal and body temperature of a patient, which can be expanded to include other vital signs. Communication between a mobile smart-phone and the ECG and temperature acquisition apparatus is implemented using the popular personal area network standard specification Bluetooth. When utilizing MMS for transmission, the mobile phone plots the received ECG signal and displays the temperature using special application software running on the client mobile phone itself, where the plot can be captured and saved as an image before transmission. Alternatively, SMS can be selected as a transmission means, where in this scenario, dedicated application software is required at the receiving device. The experimental setup can be operated for monitoring from anywhere in the globe covered by a cellular network that offers data services.

  2. Current Status of the Personal Monitoring in Japan After the Fukushima Accident

    International Nuclear Information System (INIS)

    Koguchi, Y.; Takeuchi, N.; Yamamoto, T.

    2013-01-01

    On 11 March 2011 Japan suffered a magnitude 9.0 earthquake. The 2011 Great East Japan Earthquake created a series of massive tsunami waves that struck to the east coast of Japan, causing serious damage to Fukushima Daiichi Nuclear Power Plants (NPPs). The radioactive materials such as 134Cs and 137Cs were released into the environment in widespread area of east Japan, especially Fukushima prefecture. Many people living in Fukushima prefecture especially parents of children up to junior high school age have been worrying about the effect of health risk by contaminated radioactive materials. In addition, the International Commission on Radiological Protection (ICRP) has recommended that the dose (effective dose) limits in planned exposure situation for public is 1 mSv in a single year. Therefore, the local governments in Fukushima prefecture have decided to measure the exposed dose using passive dosemeter for public especially children in order to the health risk assessment and the optimum planning of decontamination. The RPL glass dosemeter, we called Glass Badge, based on radiophotoluminescence (RPL) technology is one of suitable dosimeters for the personal monitoring. More than 300 000 Glass Badges were distributed in Fukushima area up to the end of 2012 since the Fukushima Daiichi NPPs accident. It is very easy to know the individual dose and also useful for the health risk assessment.(author)

  3. Method for incorporation monitoring - Studies on measurement and interpretation of radionuclide excretion, particularly thorium decay products, via exhaled breath

    International Nuclear Information System (INIS)

    Anon

    1998-01-01

    The development and application of a measuring method is described for thorium incorporation monitoring by way of measuring Rn-220 (thoron) in exhaled breath. The method is intended for application to monitoring the incorporation of thorium by occupationally exposed persons in compliance with the regulatory guide on health physics monitoring for determination of whole-body dose. (orig./CB) [de

  4. A study of the NRPB fast neutron personal monitoring service

    International Nuclear Information System (INIS)

    Bartlett, D.T.; Knight, A.; Marshall, T.O.

    1975-10-01

    The NRPB Fast Neutron Personal Monitoring Service has been reviewed and modifications have been, or are being, introduced to improve the accuracy and reliability of the nuclear emulsion dosemeter employed by the Service. This report presents the conclusions of the study. Experimental results of the investigations undertaken in the course of this study, together with full details of the dosemeter and Service, are appended. (author)

  5. Joint hierarchical Gaussian process model with application to personalized prediction in medical monitoring.

    Science.gov (United States)

    Duan, Leo L; Wang, Xia; Clancy, John P; Szczesniak, Rhonda D

    2018-01-01

    A two-level Gaussian process (GP) joint model is proposed to improve personalized prediction of medical monitoring data. The proposed model is applied to jointly analyze multiple longitudinal biomedical outcomes, including continuous measurements and binary outcomes, to achieve better prediction in disease progression. At the population level of the hierarchy, two independent GPs are used to capture the nonlinear trends in both the continuous biomedical marker and the binary outcome, respectively; at the individual level, a third GP, which is shared by the longitudinal measurement model and the longitudinal binary model, induces the correlation between these two model components and strengthens information borrowing across individuals. The proposed model is particularly advantageous in personalized prediction. It is applied to the motivating clinical data on cystic fibrosis disease progression, for which lung function measurements and onset of acute respiratory events are monitored jointly throughout each patient's clinical course. The results from both the simulation studies and the cystic fibrosis data application suggest that the inclusion of the shared individual-level GPs under the joint model framework leads to important improvements in personalized disease progression prediction.

  6. Going beyond the most exposed people in a dose assessment

    Energy Technology Data Exchange (ETDEWEB)

    Hjerpe, Thomas; Broed, Robert [Facilia AB, Gustavslundsvaegen 151C, SE-167 51 Bromma (Sweden); Ikonen, Ari T.K. [Environmental Research and Assessment, EnviroCase, Ltd., Hallituskatu 1 D 4, FI-28 100 Pori (Finland)

    2014-07-01

    The dose assessment in a long-term radiation safety assessment often focus on assessing dose of a representative person to be used for determining compliance with a radiation dose constraint. This representative person is often assumed to receive a dose that is representative of the most exposed people, i.e., the more highly exposed individuals in the population. This is not always sufficient, the Finnish regulations for disposal of nuclear waste has radiation dose constraint to the most exposed people as well as for larger groups of exposed people. This work presents the methodology to assessing dose of a representative person for a larger group of exposed people as applied by Posiva in the TURVA-2012 safety case for the spent nuclear fuel disposal at Olkiluoto. In addition, annual doses from the set of biosphere calculation cases analysed in TURVA-2012 are presented and discussed. Special focus is given on explaining the differences in exposure levels and exposure routes between the estimated annual doses to representative persons for most exposed people and a larger exposed group. The results show that the annual doses to a larger group of people ranges from one to three orders of magnitude below the annual doses to the most exposed people. Furthermore, the exposure route related to food ingestion is less significant for the larger group of people compared to the most exposed people and that the exposure route related to water ingestion shows the opposite behaviour. (authors)

  7. Dose measurement during defectoscopic work using electronic personal dosimeters

    International Nuclear Information System (INIS)

    Smoldasova, J.

    2008-01-01

    Personal monitoring of the external radiation of radiation, personnel exposed to sources of ionizing radiation at a workplace is an important task of the radiological protection. Information based on the measured quantities characterizing the level of the exposure of radiation personnel enable to assess the optimum radiological protection at the relevant workplace and ascertain any deviation from the normal operation in time. Different types of personal dosimeters are used to monitor the external radiation of radiation personnel. Basically, there are two types of dosimeters, passive and active (electronic). Passive dosimeters provide information on the dose of exposure after its evaluation, while electronic dosimeters provide this information instantly. The goal of the work is to compare data acquired during different working activities using the DMC 2000 XB electronic dosimeters and the passive film dosimeters currently used at the defectoscopic workplace. (authors)

  8. Monitoring the genetic health of humans accidentally exposed to ionizing radiation of Cesium-137 in Goiania (Brazil)

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, A. da; Glickman, B.W. [Victoria Univ., BC (Canada). Dept. of Biology. Centre for Environmental Health

    1997-12-31

    A long-term genetic monitoring of the Goiania population exposed to ionizing radiation of Cesium-137 is described using cytogenetic and molecular endpoints. Two molecular methods were employed: the hprt clonal assay, involving in vitro selection of 6-thioguanine-resistant hprt mutant clones which were characterized at the molecular level using RT-PCR and genomic analysis. Ionizing radiation exposure initially elevated hprt mutation frequency which gradually diminished, so that no significant increase was observed 4.5 years after original exposure. The spectrum of hprt mutation recovered from 10 individuals exposed to relatively high doses of radiation revealed a 4-fold increase in the frequency of A:T{yields}G:C transitions. Additionally, a two-fold increase in the frequency of deletions was observed which may reflect radiation-induced DNA strand breakage; determination of micro satellite instability using fluorescent PCR and genomic DNA from mononuclear cells. The frequency distribution of somatic micro satellite alterations in exposed and non-exposed populations were not different. We estimated the risk associated with radiation exposure for the exposed Goiania population. The estimated genetic risk of dominant disorders in the first post-exposure generation was increased by approximately a 24-fold. The risk of carcinogenesis was increased by a factor of 1.5 13 refs.; e-mail: acruz at uvic.ca.; bwglick at uvic.ca

  9. Proceedings of the specialist meeting on personal dosimetry and area monitoring suitable for radon and daughter products

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    The programme of work of the OECD Nuclear Energy Agency includes topics relating to radiation and environmental protection matters in mining and milling operations. A first Specialist Meeting on Personal Dosimetry and Area Monitoring suitable for Radon and Daughter Products was organised in October 1976 at Elliot Lake, Canada. The proceedings were published by NEA some months later. Following an enquiry among interested persons, NEA decided to organise a new meeting on the same subject in Paris from 20th to 22nd November 1978. The meeting dealt with questions relating to personal dosimetry techniques, the monitoring of the atmosphere in mines and their neighbourhood, as well as in buildings

  10. Rapid, low cost prototyping of transdermal devices for personal healthcare monitoring

    Directory of Open Access Journals (Sweden)

    Sanjiv Sharma

    2017-04-01

    Full Text Available The next generation of devices for personal healthcare monitoring will comprise molecular sensors to monitor analytes of interest in the skin compartment. Transdermal devices based on microneedles offer an excellent opportunity to explore the dynamics of molecular markers in the interstitial fluid, however good acceptability of these next generation devices will require several technical problems associated with current commercially available wearable sensors to be overcome. These particularly include reliability, comfort and cost. An essential pre-requisite for transdermal molecular sensing devices is that they can be fabricated using scalable technologies which are cost effective.We present here a minimally invasive microneedle array as a continuous monitoring platform technology. Method for scalable fabrication of these structures is presented. The microneedle arrays were characterised mechanically and were shown to penetrate human skin under moderate thumb pressure. They were then functionalised and evaluated as glucose, lactate and theophylline biosensors. The results suggest that this technology can be employed in the measurement of metabolites, therapeutic drugs and biomarkers and could have an important role to play in the management of chronic diseases. Keywords: Microneedles, Minimally invasive sensors, Continuous glucose monitoring (CGM, Continuous lactate monitoring (CLM, Interstitial therapeutic drug monitoring (iTDM

  11. Metabolism and toxicology of plutonium-239 - evaluation of the internal contamination of persons professionally exposed (1963)

    International Nuclear Information System (INIS)

    Henry, Ph.

    1963-01-01

    After reviewing the main metabolic and toxicological properties of plutonium 239 as well as the professional norms now in force, the report considers the difficult problem of the evaluation of the internal contamination of persons professionally exposed. This evaluation is dependent on the practical organisation of the supervision involved: - systematic supervision by periodic analysis of urinary Pu and special supervision in the case of incidents by an examination adapted to each case. A simple interpretation of the systematic analyses, as well as the evaluation methods used in the main cases of occidental contamination are outlined. (author) [fr

  12. Energy Use and Power Levels in New Monitors and Personal Computers; TOPICAL

    International Nuclear Information System (INIS)

    Roberson, Judy A.; Homan, Gregory K.; Mahajan, Akshay; Nordman, Bruce; Webber, Carrie A.; Brown, Richard E.; McWhinney, Marla; Koomey, Jonathan G.

    2002-01-01

    Our research was conducted in support of the EPA ENERGY STAR Office Equipment program, whose goal is to reduce the amount of electricity consumed by office equipment in the U.S. The most energy-efficient models in each office equipment category are eligible for the ENERGY STAR label, which consumers can use to identify and select efficient products. As the efficiency of each category improves over time, the ENERGY STAR criteria need to be revised accordingly. The purpose of this study was to provide reliable data on the energy consumption of the newest personal computers and monitors that the EPA can use to evaluate revisions to current ENERGY STAR criteria as well as to improve the accuracy of ENERGY STAR program savings estimates. We report the results of measuring the power consumption and power management capabilities of a sample of new monitors and computers. These results will be used to improve estimates of program energy savings and carbon emission reductions, and to inform rev isions of the ENERGY STAR criteria for these products. Our sample consists of 35 monitors and 26 computers manufactured between July 2000 and October 2001; it includes cathode ray tube (CRT) and liquid crystal display (LCD) monitors, Macintosh and Intel-architecture computers, desktop and laptop computers, and integrated computer systems, in which power consumption of the computer and monitor cannot be measured separately. For each machine we measured power consumption when off, on, and in each low-power level. We identify trends in and opportunities to reduce power consumption in new personal computers and monitors. Our results include a trend among monitor manufacturers to provide a single very low low-power level, well below the current ENERGY STAR criteria for sleep power consumption. These very low sleep power results mean that energy consumed when monitors are off or in active use has become more important in terms of contribution to the overall unit energy consumption (UEC

  13. Commercial Smartphone-Based Devices and Smart Applications for Personalized Healthcare Monitoring and Management.

    Science.gov (United States)

    Vashist, Sandeep Kumar; Schneider, E Marion; Luong, John H T

    2014-08-18

    Smartphone-based devices and applications (SBDAs) with cost effectiveness and remote sensing are the most promising and effective means of delivering mobile healthcare (mHealthcare). Several SBDAs have been commercialized for the personalized monitoring and/or management of basic physiological parameters, such as blood pressure, weight, body analysis, pulse rate, electrocardiograph, blood glucose, blood glucose saturation, sleeping and physical activity. With advances in Bluetooth technology, software, cloud computing and remote sensing, SBDAs provide real-time on-site analysis and telemedicine opportunities in remote areas. This scenario is of utmost importance for developing countries, where the number of smartphone users is about 70% of 6.8 billion cell phone subscribers worldwide with limited access to basic healthcare service. The technology platform facilitates patient-doctor communication and the patients to effectively manage and keep track of their medical conditions. Besides tremendous healthcare cost savings, SBDAs are very critical for the monitoring and effective management of emerging epidemics and food contamination outbreaks. The next decade will witness pioneering advances and increasing applications of SBDAs in this exponentially growing field of mHealthcare. This article provides a critical review of commercial SBDAs that are being widely used for personalized healthcare monitoring and management.

  14. Associations Between Personality Traits and Adherence to Antidepressants Assessed Through Self-Report, Electronic Monitoring, and Pharmacy Dispensing Data: A Pilot Study.

    Science.gov (United States)

    Wouters, Hans; Amin, Darya F H; Taxis, Katja; Heerdink, Eibert R; Egberts, Antoine C G; Gardarsdottir, Helga

    2016-10-01

    Treatment with antidepressants is often compromised by substantial nonadherence. To understand nonadherence, specific medication-related behaviors and beliefs have been studied, but less is known about broader and temporally stable personality "traits." Furthermore, adherence has often been assessed by a single method. Hence, we investigated associations between the Big Five personality traits and adherence assessed by self-report, electronic drug use monitoring, and dispensing data. Using the Big Five Inventory, we assessed the personality traits "openness," "conscientiousness," "extraversion," "agreeableness," and "neuroticism" of patients treated with antidepressants who were invited through community pharmacies. Self-reported adherence was assessed with the Medication Adherence Rating Scale (score >24), electronic monitoring with medication event monitoring system (MEMS) devices (therapy days missed ≤ 10% and personality traits, the third and fourth quartiles of "conscientiousness" were associated with better self-reported adherence (odds ratio, 3.63; 95% confidence interval, 1.34-9.86 and odds ratio, 2.97; 95% confidence interval, 1.09-8.08; P ≤ 0.05). No relationships were found between personality traits and adherence assessed through electronic drug use monitoring or dispensing data. We therefore conclude that adherence to antidepressant therapy seems to be largely unrelated to personality traits.

  15. Implementation of internal monitoring programs for workers occupationally exposed by 131I in nuclear medicine services in Brazil

    International Nuclear Information System (INIS)

    Oliveira, S.M.; Dantas, A.L.A.; Dantas, B.M.

    2017-01-01

    In nuclear medicine services (NMS), workers routinely handle radionuclides for diagnostic and therapy. This practice represents a risk of incorporation by these radionuclides. The International Atomic Energy Agency (IAEA) recommends the implementation of an internal monitoring program on workers exposed to annual effective doses greater than 1 mSv, as for example, those who handle 131 I for therapy in NMS. Currently, in Brazil, there are not enough available laboratories qualified to provide internal monitoring services to attend all possible demand of internal monitoring if it such regulation were applied by the Brazilian Nuclear Regulatory Board (CNEN). The objective of this work is to disseminate simple and inexpensive methods for in vivo routine thyroid monitoring of 131 I using equipment available in the NMS. Devices available in two public hospitals located in the city of Rio de Janeiro were calibrated for use in occupational internal monitoring. The equipment evaluated in this work presented enough sensitivity for such application, being suitable to access intakes of 131 I in the thyroid and able to estimate doses below 1 mSv. (author)

  16. Vascular and lung function related to ultrafine and fine particles exposure assessed by personal and indoor monitoring: a cross-sectional study

    DEFF Research Database (Denmark)

    Olsen, Yulia; Karottki, Dorina Gabriela; Jensen, Ditte Marie

    2014-01-01

    -related effects. Methods: Associations between vascular and lung function, inflammation markers and exposure in terms of particle number concentration (PNC; d = 10-300 nm) were studied in a cross-sectional design with personal and home indoor monitoring in the Western Copenhagen Area, Denmark. During 48-h, PNC...... and PM2.5 were monitored in living rooms of 60 homes with 81 non-smoking subjects (30-75 years old), 59 of whom carried personal monitors both when at home and away from home. We measured lung function in terms of the FEV1/FVC ratio, microvascular function (MVF) and pulse amplitude by digital artery...... tonometry, blood pressure and biomarkers of inflammation including C-reactive protein, and leukocyte counts with subdivision in neutrophils, eosinophils, monocytes, and lymphocytes in blood. Results: PNC from personal and stationary home monitoring showed weak correlation (r = 0.15, p = 0.24). Personal UFP...

  17. [Analytical quality in biological monitoring of workers exposed to chemicals: experience of the Prevention and Safety at the Workplace Service in Modena].

    Science.gov (United States)

    Alpaca, R I Paredes; Migliore, A; Di Rico, R; Canali, Claudia; Rota, Cristina; Trenti, T; Cariani, Elisabetta

    2010-01-01

    The quality of laboratory data is one of the main factors in guaranteeing efficacy of biological monitoring. To analyze the quality of laboratory data used for biological monitoring of exposed workers. A survey involving 18 companies employing 945 workers in the area of Modena, Italy, was carried out in 2008. Most of the 9 private laboratories receiving biological samples did not perform directly part or all of the laboratory assessments requested, but this was not indicated in the final report. Major problems were observed in the application of internal quality control, and only one laboratory participated in external quality assessment for blood lead measurements. Our results raise major concerns on the traceability and reliability of laboratory assessments performed for biomonitoring of exposed workers. Systematic evaluation of the quality of analytical data would be highly recommendable.

  18. Prospective study of total cholesterol amount in the blood of the persons exposed to ionizing radiation due to Chernobyl accident

    International Nuclear Information System (INIS)

    Chobot'ko, G.M.

    1998-01-01

    The blood of the men aged 20-59 residing in Kyiv after the accident and that of the participants of the accident clean-up aged 25-55 has been studying for 10 years. The nature of the observed changes in blood cholesterol amount is atherogenic, which should be taken into account when taking preventive and therapeutic measures in the persons exposed to different dosed of ionizing radiation

  19. The diesel exhaust in miners study: II. Exposure monitoring surveys and development of exposure groups.

    NARCIS (Netherlands)

    Coble, J.B.; Stewart, P.A.; Vermeulen, R.; Yereb, D.; Stanevich, R.; Blair, A.; Silverman, D.T.; Attfield, M.

    2010-01-01

    Air monitoring surveys were conducted between 1998 and 2001 at seven non-metal mining facilities to assess exposure to respirable elemental carbon (REC), a component of diesel exhaust (DE), for an epidemiologic study of miners exposed to DE. Personal exposure measurements were taken on workers in a

  20. Professional exposure of medical workers: radiation levels, radiation risk and personal dose monitoring

    International Nuclear Information System (INIS)

    Bai Guang

    2005-01-01

    The application of radiation in the field of medicine is the most active area. Due to the rapid and strong development of intervention radiology at present near 20 years, particularly, the medical workers become a popularize group which most rapid increasing and also receiving the must high of professional exposure dose. Because, inter alias, radiation protection management nag training have not fully follow up, the aware of radioactive protection and appropriate approach have tot fully meet the development and need, the professional exposure dose received by medical workers, especially those being engaged in intervention radiology, are more higher, as well as have not yet fully receiving the complete personal dose monitoring, the medical workers become the population group which should be paid the most attention to. The writer would advice in this paper that all medical workers who being received a professional radiation exposure should pay more attention to the safety and healthy they by is strengthening radiation protection and receiving complete personal dose monitoring. (authors)

  1. The relationship between occupational exposure to lead and manifestation of cardiovascular complications in persons with arterial hypertension

    International Nuclear Information System (INIS)

    Poreba, Rafal; Gac, Pawel; Poreba, Malgorzata; Andrzejak, Ryszard

    2010-01-01

    The chronic exposure to lead represents a risk factor of arterial hypertension development. Ambulatory blood pressure monitoring is the most prognostically reliable method of measuring of arterial blood pressure. The study is aimed at evaluating the relationship between occupational exposure to lead and manifestation of cardiovascular complications in patients with arterial hypertension. The studies included 73 men (mean age, 54.26 ± 8.17 years) with arterial hypertension, treated with hypotensive drugs: group I-persons occupationally exposed to lead (n = 35) and group II-individuals not exposed to lead (n = 38). An analysis of results obtained during ambulatory blood pressure monitoring disclosed significantly higher values of mean systolic blood pressure, mean blood pressure, pulse pressure, and variability of systolic blood pressure in the group of hypertensive patients occupationally exposed to lead as compared to patients with arterial hypertension but not exposed to lead. The logistic regression showed that a more advanced age, higher concentration of blood zinc protoporphyrin, and a higher mean value of pulse pressure represented independent risk factors of left ventricular hypertrophy in the group of persons with arterial hypertension and chronically exposed to lead (OR age = 1.11; OR ZnPP = 1.32; OR PP = 1,43; p < 0.05). In view of the above data demonstration that occupational exposure to lead represents an independent risk factor of increased pulse pressure may be of key importance in the process of shaping general social awareness as to harmful effects of lead compounds on human health.

  2. Nailfold Capillaroscopic Monitoring as Preventive Medicine in Subjects Exposed to Ionising Radiation

    International Nuclear Information System (INIS)

    Pennarola, R.; Perdereau, B.; Trenta, G.; Cosset, J. M.

    2004-01-01

    Capillaroscopy consists of in vivo observation of microvessels using special microscopes with a short focal length. Normally, when looking at the nail fold, where capillaroscopy is commonly used, the capillaries ares arranged like hairpins, lined up in parallel or obliquely to the field of vision in three or four layers above the subpapillary venous network, approximately 20 loops per mm''2. Ionising radiation can badly damage the skin and underlying tissues. The capillary network is among the first structures to show an effect. Moderate doses of radiation cause damage endothelial cells with hypertrophy or hyperplasia of endothelial cells, which can block capillaries while having little effect on larger vessels. Occlusion of capillaries impedes blood flow no only in nearby tissue but also in areas farther away. Capillaroscopic examination of the nail fold is irreplaceable in the field of radioprotection especially in cases of exposure of the hands. Nailfold capillaroscopic monitoring lets us observe the degree to which qualitative and quantitative alterations of the capillaries are a function of the evolution of the lesion. Therefore, for biological monitoring of subjects exposed to radiation the authors propose to use this microvascular quantitative analysis of the nailfold region. Experience, matured over many years by our team, highlights the relation between the sum of repeated exposure and the importance of tissue alterations evidenced by microcirculation. (Author) 9 refs

  3. High-resolution Mass Spectrometry of Skin Mucus for Monitoring Physiological Impacts in Fish Exposed to Wastewater Effluent at a Great Lakes AOC

    Science.gov (United States)

    High-resolution mass spectrometry is advantageous for monitoring physiological impacts and contaminant biotransformation products in fish exposed to complex wastewater effluent. We evaluated this technique using skin mucus from male and female fathead minnows (Pimephales promela...

  4. High‐resolution mass spectrometry of skin mucus for monitoring physiological impacts and contaminant biotransformation products in fathead minnows exposed to wastewater effluent

    Science.gov (United States)

    High‐resolution mass spectrometry is advantageous for monitoring physiological impacts and contaminant biotransformation products in fish exposed to complex wastewater effluent. We evaluated this technique using skin mucus from male and female fathead minnows (Pimephales pr...

  5. METHODS OF STATISTICAL MONITORING OF PROFESSIONAL ORIENTATION WORK OF SOCIAL EDUCATORS IN PERSONAL LEARNING ENVIRONMENTS

    Directory of Open Access Journals (Sweden)

    Oleksandr M. Korniiets

    2012-12-01

    Full Text Available The article deals with the application of social services WEB 2.0 for personal learning environment creation that is used for professional orientation work of social educator. The feedback is must be in personal learning environment for the effective professional orientation work. This feedback can be organized through statistical monitoring. The typical solution for organizing personal learning environment with built-in statistical surveys and statistical data processing is considered in the article. The possibilities of the statistical data collection and processing services on the example of Google Analytics are investigated.

  6. Commercial Smartphone-Based Devices and Smart Applications for Personalized Healthcare Monitoring and Management

    Directory of Open Access Journals (Sweden)

    Sandeep Kumar Vashist

    2014-08-01

    Full Text Available Smartphone-based devices and applications (SBDAs with cost effectiveness and remote sensing are the most promising and effective means of delivering mobile healthcare (mHealthcare. Several SBDAs have been commercialized for the personalized monitoring and/or management of basic physiological parameters, such as blood pressure, weight, body analysis, pulse rate, electrocardiograph, blood glucose, blood glucose saturation, sleeping and physical activity. With advances in Bluetooth technology, software, cloud computing and remote sensing, SBDAs provide real-time on-site analysis and telemedicine opportunities in remote areas. This scenario is of utmost importance for developing countries, where the number of smartphone users is about 70% of 6.8 billion cell phone subscribers worldwide with limited access to basic healthcare service. The technology platform facilitates patient-doctor communication and the patients to effectively manage and keep track of their medical conditions. Besides tremendous healthcare cost savings, SBDAs are very critical for the monitoring and effective management of emerging epidemics and food contamination outbreaks. The next decade will witness pioneering advances and increasing applications of SBDAs in this exponentially growing field of mHealthcare. This article provides a critical review of commercial SBDAs that are being widely used for personalized healthcare monitoring and management.

  7. Novel Use of a Noninvasive Hemodynamic Monitor in a Personalized, Active Learning Simulation

    Science.gov (United States)

    Zoller, Jonathan K.; He, Jianghua; Ballew, Angela T.; Orr, Walter N.; Flynn, Brigid C.

    2017-01-01

    The present study furthered the concept of simulation-based medical education by applying a personalized active learning component. We tested this novel approach utilizing a noninvasive hemodynamic monitor with the capability to measure and display in real time numerous hemodynamic parameters in the exercising participant. Changes in medical…

  8. Inter-comparison of personal monitors for nanoparticles exposure at workplaces and in the environment.

    Science.gov (United States)

    Todea, Ana Maria; Beckmann, Stefanie; Kaminski, Heinz; Bard, Delphine; Bau, Sébastien; Clavaguera, Simon; Dahmann, Dirk; Dozol, Hélène; Dziurowitz, Nico; Elihn, Karine; Fierz, Martin; Lidén, Göran; Meyer-Plath, Asmus; Monz, Christian; Neumann, Volker; Pelzer, Johannes; Simonow, Barbara Katrin; Thali, Patrick; Tuinman, Ilse; van der Vleuten, Arjan; Vroomen, Huub; Asbach, Christof

    2017-12-15

    Personal monitors based on unipolar diffusion charging (miniDiSC/DiSCmini, NanoTracer, Partector) can be used to assess the individual exposure to nanoparticles in different environments. The charge acquired by the aerosol particles is nearly proportional to the particle diameter and, by coincidence, also nearly proportional to the alveolar lung-deposited surface area (LDSA), the metric reported by all three instruments. In addition, the miniDiSC/DiSCmini and the NanoTracer report particle number concentration and mean particle size. In view of their use for personal exposure studies, the comparability of these personal monitors was assessed in two measurement campaigns. Altogether 29 different polydisperse test aerosols were generated during the two campaigns, covering a large range of particle sizes, morphologies and concentrations. The data provided by the personal monitors were compared with those obtained from reference instruments: a scanning mobility particle sizer (SMPS) for LDSA and mean particle size and a ultrafine particle counter (UCPC) for number concentration. The results indicated that the LDSA concentrations and the mean particle sizes provided by all investigated instruments in this study were in the order of ±30% of the reference value obtained from the SMPS when the particle sizes of the test aerosols generated were within 20-400nm and the instruments were properly calibrated. Particle size, morphology and concentration did not have a major effect within the aforementioned limits. The comparability of the number concentrations was found to be slightly worse and in the range of ±50% of the reference value obtained from the UCPC. In addition, a minor effect of the particle morphology on the number concentration measurements was observed. The presence of particles >400nm can drastically bias the measurement results of all instruments and all metrics determined. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Frequency of marriage and live birth among survivors prenatally exposed to the atomic bomb

    International Nuclear Information System (INIS)

    Blot, W.J.; Shimizu, Y.; Kato, H.; Miller, R.W.

    1975-01-01

    Frequency of marriage and birth as of January 1973 was determined for persons exposed in utero to the atomic bombs in 1945 and for controls. The marriage rate was lower in persons heavily exposed in utero than in the non-exposed or lightly exposed. This difference is attributed partly to the lesser marriageability of persons with mental retardation who are significantly more numerous among the heavily exposed, and partly to unmeasured variables, possibly including social discrimination against survivors of the atomic bomb. No consistent relation was observed between radiation exposure and three reproductive indices: childless marriages, number of births, and interval between marriage and first birth

  10. Asbestos-related radiographic findings among household contacts of workers exposed to Libby vermiculite: impact of workers' personal hygiene practices.

    Science.gov (United States)

    Hilbert, Timothy J; Franzblau, Alfred; Dunning, Kari K; Borton, Eric K; Rohs, Amy M; Lockey, James E

    2013-11-01

    To explore the potential impact of worker hygiene by determining the prevalence of radiographic changes consistent with asbestos exposure among household contacts of workers exposed to Libby vermiculite that contained amphibole fibers. Workers and household contacts had chest radiographs and completed questionnaires regarding hygiene and potential exposure pathways. Participants included 191 household contacts of 118 workers. One household contact (0.5%) had localized pleural thickening, and three (1.6%) had irregular opacities at profusion category 1/0 or greater. Worker radiographs demonstrated pleural changes in 45% and irregular opacities at profusion category 1/0 or greater in 8%. Libby vermiculite-exposed workers demonstrated an elevated prevalence of pleural and interstitial chest radiographic changes. There was, however, no increased prevalence of similar changes among household contacts, likely because of personal hygiene measures taken by the majority of workers.

  11. Monitoring of Persons at the Exit from Bohunice NPP

    International Nuclear Information System (INIS)

    Kaizer, J.; Svitek, J.

    2001-01-01

    Full text: IAEA defines the principal requirement 'defence in depth' as a multilayer system in its authorised document - International Basic Safety Standards for Protection against Ionising Radiation, Safety Series No. 115. The principle of the multilayer system is: a failure at one zone is compensated or corrected at subsequent zones. The main argument why Bohunice NPP modernised its monitoring system at the exit from NPP was the implementation of the principle 'defence in depth'. Several instruments PM7 (Eberline) equipped with the plastic scintillation detectors had been bought because of the modernisation. The instruments had to be integrated into overall security system NPP without any restriction to the number of passing people. The supplier had to modify the basic instrument operation. NPP required a 'dynamic' monitoring version, this means the operation without stopping of a person within the instrument. After the modification the value of the RDA (Reliable Detectable Activity) of the instruments PM7 was within the interval 9.25-10.4 kBq for 137 Cs (dotted source in the middle of the instrument). RDA for the mix of activation products was 2-3 times lower. In conclusion of our paper the results of the monitoring are presented within tree years as well as a discussion about these results. Maximum values of contaminations measured were very low (several kBq) that represented very low risk from potential exposure. (author)

  12. Efficiency Improvement Opportunities for Personal Computer Monitors. Implications for Market Transformation Programs

    Energy Technology Data Exchange (ETDEWEB)

    Park, Won Young [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Phadke, Amol [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Shah, Nihar [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-06-29

    Displays account for a significant portion of electricity consumed in personal computer (PC) use, and global PC monitor shipments are expected to continue to increase. We assess the market trends in the energy efficiency of PC monitors that are likely to occur without any additional policy intervention and estimate that display efficiency will likely improve by over 40% by 2015 compared to today’s technology. We evaluate the cost effectiveness of a key technology which further improves efficiency beyond this level by at least 20% and find that its adoption is cost effective. We assess the potential for further improving efficiency taking into account the recent development of universal serial bus (USB) powered liquid crystal display (LCD) monitors and find that the current technology available and deployed in USB powered monitors has the potential to deeply reduce energy consumption by as much as 50%. We provide insights for policies and programs that can be used to accelerate the adoption of efficient technologies to capture global energy saving potential from PC monitors which we estimate to be 9.2 terawatt-hours [TWh] per year in 2015.

  13. Introduction of a new dosimetry system based on optically stimulated luminescence (OSL) in our personal monitoring service

    International Nuclear Information System (INIS)

    Hubner, S.

    2014-08-01

    The personal monitoring service named Auswertungsstelle is part of the Helmholtz Zentrum Munchen, a non-profit-making research center in Germany. As one of the four monitoring services in Germany, we have been a reliable partner in radiation protection for more than 60 years. With about 1.9 million dose assessments per year, we are the largest monitoring service in Europe. For dozens of years, our main dosimeter used in whole-body dosimetry has been a film dosimeter. Although its dosimetric properties are still up to date, film dosimetry won.t be a sustainable technique for the use in monitoring services. Therefore, a project with the objective of investigating alternative dosimetric materials and methods was launched in the late 1990 at the Helmholtz Zentrum Munchen. Based on this research work, the use of Be O as an OSL dosimeter was studied by the radiation physics group of the Tu Dresden, by order and on account of the Auswertungsstelle at the Helmholtz Zentrum Munchen. It was shown, that ceramic Be O features promising dosimetric properties, making Be O detectors particularly suitable for being used in all applications in whole-body dosimetry measuring photons. Ceramic Be O material has an excellent resistance to environmental influences. The Be O chips are almost tissue equivalent. Therefore, these detectors show low photon energy dependence. A new personal dosimetry system based on the OSL dosimetry of Be O was developed. Applying this system, the Auswertungsstelle offers OSL-dosimeters for official monitoring of the Personal Dose Equivalent Hp(10) since 2011. This OSL-System is accredited according to DIN IEC 62387 and we obtained the corresponding type approval by the Ptb, the national metrology institute in Germany. Sophisticated logistics was developed and installed. High degree of automation was achieved by robots for dosimeter assembly and machines for packing, labelling and unpacking of the dosimeters. To become a sustainable dosimetry system not only

  14. Introduction of a new dosimetry system based on optically stimulated luminescence (OSL) in our personal monitoring service

    Energy Technology Data Exchange (ETDEWEB)

    Hubner, S., E-mail: stephan.huebner@helmholtz-muenchen.de [Helmholtz Zentrum Munchen, German Research Center for Environmental Health, D-80219, Munich (Georgia)

    2014-08-15

    The personal monitoring service named Auswertungsstelle is part of the Helmholtz Zentrum Munchen, a non-profit-making research center in Germany. As one of the four monitoring services in Germany, we have been a reliable partner in radiation protection for more than 60 years. With about 1.9 million dose assessments per year, we are the largest monitoring service in Europe. For dozens of years, our main dosimeter used in whole-body dosimetry has been a film dosimeter. Although its dosimetric properties are still up to date, film dosimetry won.t be a sustainable technique for the use in monitoring services. Therefore, a project with the objective of investigating alternative dosimetric materials and methods was launched in the late 1990 at the Helmholtz Zentrum Munchen. Based on this research work, the use of Be O as an OSL dosimeter was studied by the radiation physics group of the Tu Dresden, by order and on account of the Auswertungsstelle at the Helmholtz Zentrum Munchen. It was shown, that ceramic Be O features promising dosimetric properties, making Be O detectors particularly suitable for being used in all applications in whole-body dosimetry measuring photons. Ceramic Be O material has an excellent resistance to environmental influences. The Be O chips are almost tissue equivalent. Therefore, these detectors show low photon energy dependence. A new personal dosimetry system based on the OSL dosimetry of Be O was developed. Applying this system, the Auswertungsstelle offers OSL-dosimeters for official monitoring of the Personal Dose Equivalent Hp(10) since 2011. This OSL-System is accredited according to DIN IEC 62387 and we obtained the corresponding type approval by the Ptb, the national metrology institute in Germany. Sophisticated logistics was developed and installed. High degree of automation was achieved by robots for dosimeter assembly and machines for packing, labelling and unpacking of the dosimeters. To become a sustainable dosimetry system not only

  15. Experimental patients of drug treatment for cataracta in the persons exposed to an atomic bomb near the explosion

    Energy Technology Data Exchange (ETDEWEB)

    Sugimoto, Shigenori [Hiroshima City (Japan)

    1976-03-01

    This paper describes the clinical process of 4 persons exposed to an atomic bomb near the explosion in Nagasaki who have received chemotherapy because of incipient senile cataracta associated by cataracta due to an atomic bomb. The dropping of Catalin and Tathion in the eyes, oral administration of Thiola, and injection of Glutathione were done. Dramatic results were not obtained. However, when the administration was done at the time of slight corneal opacity, it did not developed. Therefore, it can't be denied now that the chemotherapy is effective.

  16. Experimental patients of drug treatment for cataracta in the persons exposed to an atomic bomb near the explosion

    International Nuclear Information System (INIS)

    Sugimoto, Shigenori

    1976-01-01

    This paper describes the clinical process of 4 persons exposed to an atomic bomb near the explosion in Nagasaki who have received chemotherapy because of incipient senile cataracta associated by cataracta due to an atomic bomb. The dropping of Catalin and Tathion in the eyes, oral administration of Thiola, and injection of Glutathione were done. Dramatic results were not obtained. However, when the administration was done at the time of slight corneal opacity, it did not developed. Therefore, it can't be denied now that the chemotherapy is effective. (Kanao, N.)

  17. Implementation of internal monitoring programs for workers occupationally exposed by {sup 131}I in nuclear medicine services in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, S.M.; Dantas, A.L.A.; Dantas, B.M., E-mail: salomao.marques@ymail.com [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Div. de Dosimetria

    2017-07-01

    In nuclear medicine services (NMS), workers routinely handle radionuclides for diagnostic and therapy. This practice represents a risk of incorporation by these radionuclides. The International Atomic Energy Agency (IAEA) recommends the implementation of an internal monitoring program on workers exposed to annual effective doses greater than 1 mSv, as for example, those who handle {sup 131}I for therapy in NMS. Currently, in Brazil, there are not enough available laboratories qualified to provide internal monitoring services to attend all possible demand of internal monitoring if it such regulation were applied by the Brazilian Nuclear Regulatory Board (CNEN). The objective of this work is to disseminate simple and inexpensive methods for in vivo routine thyroid monitoring of {sup 131}I using equipment available in the NMS. Devices available in two public hospitals located in the city of Rio de Janeiro were calibrated for use in occupational internal monitoring. The equipment evaluated in this work presented enough sensitivity for such application, being suitable to access intakes of {sup 131}I in the thyroid and able to estimate doses below 1 mSv. (author)

  18. Statistics of official personal dosimetry and monitoring activities of the period 1994-1995

    International Nuclear Information System (INIS)

    Boerner, E.; Wittmann, A.; Wahl, W.

    1998-01-01

    The measuring laboratory of the GSF in Neuherberg is the largest of the six official supervisory laboratories in Germany. It distributes the officially approved personal dosemeters and is responsible for personal dosimetry monitoring of about 140,000 persons in the German federal states of Bavaria, Hesse, Schleswig-Holstein, and, since 1989, Baden-Wuerttmeberg. Dosemeter readouts are recorded here in a database together with personal data and data describing activities, so that the information collected can be used as a source of reference for establishing general surveys of occupational exposure to external irradiation with ionizing radiation. The report first describes the dosemeter designs and the methods applied by the GSF lab for quality assurance, then explains results of the statistical evaluation of the recent data from 1994-1995, and concludes with explaining tendencies shown by long-term curves of the collective and average annual doses recorded in the years from 1986 until 1995. (orig./CB) [de

  19. An Inexpensive High-Temporal Resolution Electronic Sun Journal for Monitoring Personal Day to Day Sun Exposure Patterns

    Directory of Open Access Journals (Sweden)

    Nathan J. Downs

    2017-11-01

    Full Text Available Exposure to natural sunlight, specifically solar ultraviolet (UV radiation contributes to lifetime risks of skin cancer, eye disease, and diseases associated with vitamin D insufficiency. Improved knowledge of personal sun exposure patterns can inform public health policy; and help target high-risk population groups. Subsequently, an extensive number of studies have been conducted to measure personal solar UV exposure in a variety of settings. Many of these studies, however, use digital or paper-based journals (self-reported volunteer recall, or employ cost prohibitive electronic UV dosimeters (that limit the size of sample populations, to estimate periods of exposure. A cost effective personal electronic sun journal (ESJ built from readily available infrared photodiodes is presented in this research. The ESJ can be used to complement traditional UV dosimeters that measure total biologically effective exposure by providing a time-stamped sun exposure record. The ESJ can be easily attached to clothing and data logged to personal devices (including fitness monitors or smartphones. The ESJ improves upon self-reported exposure recording and is a cost effective high-temporal resolution option for monitoring personal sun exposure behavior in large population studies.

  20. Inter-comparison of personal monitors for nanoparticles exposure at workplaces and in the environment

    NARCIS (Netherlands)

    Todea, A.M.; Beckmann, S.; Kaminski, H.; Bard, D.; Bau, S.; Clavaguera, S.; Dahmann, D.; Dozol, H.; Dziurowitz, N.; Elihn, K.; Fierz, M.; Lidén, G.; Meyer-Plath, A.; Monz, C.; Neumann, V.; Pelzer, J.; Simonow, B.K.; Thali, P.; Tuinman, I.; Vleuten, A. van der; Vroomen, H.; Asbach, C.

    2017-01-01

    Personal monitors based on unipolar diffusion charging (miniDiSC/DiSCmini, NanoTracer, Partector) can be used to assess the individual exposure to nanoparticles in different environments. The charge acquired by the aerosol particles is nearly proportional to the particle diameter and, by

  1. Who Got All of My Personal Data? Enabling Users to Monitor the Proliferation of Shared Personally Identifiable Information

    OpenAIRE

    Labitzke , Sebastian

    2011-01-01

    Part 4: Privacy and Transparency in the Age of Cloud Computing; International audience; The risk involved when users publish information, which becomes available to an unintentional broad audience via online social networks is evident. It is especially difficult for users of social networks to determine who will get the information before it is shared. Moreover, it is impossible to monitor data flows or to control the access to personal data after sharing the information. In contrast to enter...

  2. Ionising radiation and risk of death from leukaemia and lymphoma in radiation-monitored workers (INWORKS)

    Energy Technology Data Exchange (ETDEWEB)

    Lorenz, Bernd

    2015-07-01

    Since July 2015 the study ''ionising radiation and risk of death from leukaemia and lymphoma in radiation-monitored workers (INWORKS) - an international cohort study'' is available. INWORKS comprised data from 300.000 occupational exposed and dosimetric monitored persons from France, USA and UK. The contribution is a critical discussion of this study with respect to the conclusion of a strong evidence of positive associations between protracted low-dose irradiation exposure and leukemia.

  3. A novel paradigm for telemedicine using the personal bio-monitor.

    Science.gov (United States)

    Bhatikar, Sanjay R; Mahajan, Roop L; DeGroff, Curt

    2002-01-01

    The foray of solid-state technology in the medical field has yielded an arsenal of sophisticated healthcare tools. Personal, portable computing power coupled with the information superhighway open up the possibility of sophisticated healthcare management that will impact the medical field just as much. The full synergistic potential of three interwoven technologies: (1) compact electronics, (2) World Wide Web, and (3) Artificial Intelligence is yet to be realized. The system presented in this paper integrates these technologies synergistically, providing a new paradigm for healthcare. Our idea is to deploy internet-enabled, intelligent, handheld personal computers for medical diagnosis. The salient features of the 'Personal Bio-Monitor' we envisage are: (1) Utilization of the peripheral signals of the body which may be acquired non-invasively and with ease, for diagnosis of medical conditions; (2) An Artificial Neural Network (ANN) based approach for diagnosis; (3) Configuration of the diagnostic device as a handheld for personal use; (4) Internet connectivity, following the emerging bluetooth protocol, for prompt conveyance of information to a patient's health care provider via the World Wide Web. The proposal is substantiated with an intelligent handheld device developed by the investigators for pediatric cardiac auscultation. This device performed accurate diagnoses of cardiac abnormalities in pediatrics using an artificial neural network to process heart sounds acquired by a low-frequency microphone and transmitted its diagnosis to a desktop PC via infrared. The idea of the personal biomonitor presented here has the potential to streamline healthcare by optimizing two valuable resources: physicians' time and sophisticated equipment time. We show that the elements of such a system are in place, with our prototype. Our novel contribution is the synergistic integration of compact electronics' technology, artificial neural network methodology and the wireless web

  4. Efficiency improvement opportunities for personal computer monitors. Implications for market transformation programs

    Energy Technology Data Exchange (ETDEWEB)

    Park, Won Young; Phadke, Amol; Shah, Nihar [Environmental Energy Technologies Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States)

    2013-08-15

    Displays account for a significant portion of electricity consumed in personal computer (PC) use, and global PC monitor shipments are expected to continue to increase. We assess the market trends in the energy efficiency of PC monitors that are likely to occur without any additional policy intervention and estimate that PC monitor efficiency will likely improve by over 40 % by 2015 with saving potential of 4.5 TWh per year in 2015, compared to today's technology. We discuss various energy-efficiency improvement options and evaluate the cost-effectiveness of three of them, at least one of which improves efficiency by at least 20 % cost effectively beyond the ongoing market trends. We assess the potential for further improving efficiency taking into account the recent development of universal serial bus-powered liquid crystal display monitors and find that the current technology available and deployed in them has the potential to deeply and cost effectively reduce energy consumption by as much as 50 %. We provide insights for policies and programs that can be used to accelerate the adoption of efficient technologies to further capture global energy saving potential from PC monitors which we estimate to be 9.2 TWh per year in 2015.

  5. Indoor, outdoor, and personal exposure monitoring of particulate air pollution: the Baltimore elderly epidemiology-exposure pilot study

    Science.gov (United States)

    Williams, Ron; Creason, John; Zweidinger, Roy; Watts, Randall; Sheldon, Linda; Shy, Carl

    A 17-day pilot study investigating potential PM exposures of an elderly population was conducted near Baltimore, Maryland. Collection of residential indoor, residential outdoor, and ambient monitoring data associated with the subjects living at a common retirement facility was integrated with results from a paired epidemiological pilot study. This integration was used to investigate the potential pathophysiological health effects resulting from daily changes in estimated PM exposures with results reported elsewhere. Objectives of the exposure study were to determine the feasibility of performing PM exposure assessment upon an elderly population and establishing relationships between the various exposure measures including personal monitoring. PM 2.5 was determined to be the dominant outdoor size fraction (0.83 PM 2.5/PM 10 mass ratio by dichot monitoring). Individual 24-h PM 1.5 personal exposures ranged from 12 to 58 μg m -3. Comparison of data from matched sampling dates resulted in mean daily PM 1.5 personal, PM 2.5 outdoor, and PM 1.5 indoor concentrations of 34, 17, and 17 μg m -3, respectively. Activity patterns of the study population indicated a generally sedentary population spending a mean of 96% of each day indoors. Future studies would benefit from the use of a consistent sampling methodology across a larger number of PM measurement sites relevant to the elderly subjects, as well as a larger personal PM exposure study population to more successfully collect data needed in matched epidemiological-exposure studies.

  6. Strategies for monitoring outcomes in HIV-exposed uninfected children in the United Kingdom

    Directory of Open Access Journals (Sweden)

    Claire eThorne

    2016-05-01

    Full Text Available Surveillance of pregnancies in women living with HIV is carried out on a national basis in the United Kingdom (UK through the National Study of HIV in Pregnancy and Childhood (NSHPC. There are currently around 1100-1200 HIV-exposed uninfected (HEU infants born every year in the UK, where vertical transmission of HIV now occurs in fewer than five in every 1000 pregnancies. By the end of 2014, there was a cumulative total of more than 15,000 HEU children with any combination antiretroviral therapy (cART exposure and more than 5,000 with cART exposure from conception in the UK. HEU infants are increasingly being exposed to newer antiretroviral drugs for which less is known regarding both short and longer-term safety. In this commentary, we describe the approaches that have been taken to explore health outcomes in HEU children born in the UK. This includes the Children exposed to AntiRetroviral Therapy (CHART Study, which was a consented follow-up study carried out in 2002-2005 of HEU children born in 1996-2004. The CHART Study showed that 4% of HEU children enrolled had a major health or development problem in early childhood; this was within expected UK norms but the study was limited by small numbers and short-term follow-up. However, the problems with recruitment and retention that were encountered within the CHART Study demonstrated that comprehensive, clinic-based follow-up was not a feasible approach for long-term assessment of HEU children in the UK. We describe an alternative approach developed to monitor some aspects of their long-term health, involving the flagging of HEU infants for death and cancer registration with the UK Office for National Statistics. Some of the ethical concerns regarding investigation of long-term outcomes of in utero and perinatal exposure to antiretrovirals including those relating to consent and confidentiality are also discussed.

  7. Personal radiation monitoring

    International Nuclear Information System (INIS)

    Julius, H.W.

    1976-01-01

    This report reviews the context of a primary university course in individual radiation monitoring. A brief account of the regulations and permissible doses is given. The principles and design of film dosemeters, thermoluminescent dosemeters and the whole-body counting technique are treated

  8. Personal neutron monitoring using TLD albedo combined with etched tracks detector

    Energy Technology Data Exchange (ETDEWEB)

    Tsujimura, N.; Momose, T. [Japan Nuclear Cycle Development Institute, Ibarakiken (Japan)

    2002-07-01

    The albedo dosimetry has been carried out in personal neutron monitoring in the MOX fuel plant of JNC Tokai Works, however, it has shortcomings mainly due to the inherently poor energy response. This paper describes our efforts to overcome these difficulties in practical use of albedo dosemeters. The following four subjects are presented: (1) the neutron energy response functions of albedo TLD obtained from the mono-energetic neutron irradiation experiments and the Monte-Carlo calculations, (2) the location- dependent correction factors calculated from the response functions and neutron energy spectra measured in the workplaces, (3) the results of the international personal neutron dosimetry intercomparison program, and (4) the operational comparison program of TLD albedo and etched tracks detector worn by workers engaged in the fabrication process of the MOX fuel plant. Finally, the characteristics of the combination neutron dosemeter using TLD albedo and solid state etched track detector are summarized.

  9. The personal dosimetry in Mexico; La dosimetria personal en Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Salazar, M.A. [Proxtronics/ Asesoria Integral en Dosimetria Termoluminiscente S.A. de C.V., Canal de Miramontes 2030-14, Col. Educacion, 04400 Mexico D.F. (Mexico)]. e-mail: aidtsa@avantel.net

    2006-07-01

    The Personal Dosimetry in Mexico, has an approximately 30 year-old history; and it had been and it is at the moment, one of the more important resources with which the personnel that works with ionizing radiation sources counts for its protection. The Personal Dosimetry begins with the film dosimetry, technique that even continues being used at the present time by some users, and the main reason of its use is for economic reasons. At the moment this technique, it has been surpassed, by the Thermoluminescent dosimetry, which has taken a lot of peak, mainly by the technological development with which it is counted at the present time; what has given as a result that this technique becomes tip technology; that supported in the characteristic of the used materials, as the handling and processing of the information associated with the new PC, digitizer cards, software etc, what has allowed increases it potential. In this work the current necessities of the market are presented as well as an analysis of the future real necessities in Mexico, at national level, the companies that provide this service and that they spread to satisfy this necessity of the market, including the different used technologies are also mentioned. The application ranges, at the same time, of the advantages and disadvantages of the different systems of Personal Dosimetry in the market. The companies that at the moment provide the service of Personal Dosimetry, its use materials and equipment in indistinct form, for the monitoring of gamma radiation, beta particles, different qualities of x-ray radiation, and sometimes neutrons. The monitoring of the exposed personnel at the diverse sources of ionizing radiation mentioned is carried out in many occasions without having with the materials (detectors), neither the appropriate infrastructure and therefore without the quality control that guarantees a correct evaluation of the dose equivalent, as a result of the exposure to the ionizing radiations; it

  10. Mobile personal health records for pregnancy monitoring functionalities: Analysis and potential.

    Science.gov (United States)

    Bachiri, Mariam; Idri, Ali; Fernández-Alemán, José Luis; Toval, Ambrosio

    2016-10-01

    Personal Health Records (PHRs) are a rapidly growing area of health information technology. PHR users are able to manage their own health data and communicate with doctors in order to improve healthcare quality and efficiency. Mobile PHR (mPHR) applications for mobile devices have obtained an interesting market quota since the appearance of more powerful mobile devices. These devices allow users to gain access to applications that used to be available only for personal computers. This paper analyzes the functionalities of mobile PHRs that are specific to pregnancy monitoring. A well-known Systematic Literature Review (SLR) protocol was used in the analysis process. A questionnaire was developed for this task, based on the rigorous study of scientific literature concerning pregnancy and applications available on the market, with 9 data items and 35 quality assessments. The data items contain calendars, pregnancy information, health habits, counters, diaries, mobile features, security, backup, configuration and architectural design. A total of 33 mPHRs for pregnancy monitoring, available for iOS and Android, were selected from Apple App store and Google Play store, respectively. The results show that none of the mPHRs selected met 100% of the functionalities analyzed in this paper. The highest score achieved was 77%, while the lowest was 17%. In this paper, these features are discussed and possible paths for future development of similar applications are proposed, which may lead to a more efficient use of smartphone capabilities. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. The design of a wireless portable device for personalized ultraviolet monitoring

    Science.gov (United States)

    Amini, Navid; Matthews, Jerrid E.; Vahdatpour, Alireza; Sarrafzadeh, Majid

    2009-08-01

    The skin care product market is growing due to the threat of ultraviolet (UV) radiation caused by the destruction of the ozone layer, increasing demand for tanning, and the tendency to wear less clothing. Accordingly, there is a potential demand for a personalized UV monitoring system, which can play a fundamental role in skin cancer prevention by providing measurements of UV radiation intensities and corresponding recommendations. Furthermore, the need for such device becomes more vital since it has turned out that in some places (e.g., on snowy mountains) the UV exposure gets doubled, while individuals are unaware of this fact. This paper highlights the development and initial validation of a wireless and portable embedded system for personalized UV monitoring which is based on a novel software architecture, a high-end UV sensor, and conventional PDA (or a cell phone). In terms of short-term applications, by calculating the UV index, it informs the users about their maximum recommended sun exposure time by taking their skin type and sun protection factor (SPF) of the applied sunscreen into consideration. As for long-term applications, given that the damage caused by UV light is accumulated over days, it is able to keep a record of the amount of UV received over a certain course of time, from a single day to a month. Low energy consumption and high accuracy in estimating the UV index are salient features of this system.

  12. Psycho-social aspects of personal health monitoring: a descriptive literature review.

    Science.gov (United States)

    Muehlan, Holger; Schmidt, Silke

    2013-01-01

    We aimed at providing a short review on already published studies addressing psycho-social issues of personal health monitoring (PHM). Both core questions addressed within this review are: What is the impact of PHM on intended psycho-social and health-related outcomes? And which psycho-social issues affected by or related to PHM have already been investigated? This descriptive review based on a literature search using various databases (Psycinfo, Psyndex, Pubmed, SSCI). Resulting 428 abstracts were coded regarding their psycho-social content. Inspection of results was carried out along the relevance of the papers regarding psycho-social issues. Research in PHM focuses on telemonitoring and smart home applications: Tele-monitoring studies are directed to outcome-related questions, smart home studies to feasibility issues. Despite of technological matters, comparability of both systems in psycho-social issues is lacking. Tele-monitoring has been proven for impact on patient groups with chronic diseases, yet smart home still lacks evidence in health-related and psycho-social matters. Smart home applications have been investigated with respect to attitudes, perceptions and concerns of end-users, telemonitoring regarding acceptance and adherence.

  13. Renographic curve of persons exposed to mercury

    International Nuclear Information System (INIS)

    Kolenic, J.; Jurgova, T.; Zimacek, J.; Petrovicova, J.; Bilicky, J.

    1995-01-01

    In the group of 72 workers which were exposed to fumes of metallic mercury we evaluated possible nephrotoxic effect of Hg 0 . We also used nuclear renography for evaluation of kidney. Nephrotoxic effect of Hg 0 was proved by increased proteinuria and relatively frequent findings of pathological renogram. In the group with pathological renogram, elimination of Hg 0 in urine (1822.8 nmol.dm -3 ) was increased. In the group with normal finding the value was 883.7 nmol.dm -3 . These findings pointed at toxic effect of Hg 0 on kidney and suitability of radionuclide examination for disclosing of subclinical pathological changes. (authors)

  14. PhysioDroid: combining wearable health sensors and mobile devices for a ubiquitous, continuous, and personal monitoring.

    Science.gov (United States)

    Banos, Oresti; Villalonga, Claudia; Damas, Miguel; Gloesekoetter, Peter; Pomares, Hector; Rojas, Ignacio

    2014-01-01

    Technological advances on the development of mobile devices, medical sensors, and wireless communication systems support a new generation of unobtrusive, portable, and ubiquitous health monitoring systems for continuous patient assessment and more personalized health care. There exist a growing number of mobile apps in the health domain; however, little contribution has been specifically provided, so far, to operate this kind of apps with wearable physiological sensors. The PhysioDroid, presented in this paper, provides a personalized means to remotely monitor and evaluate users' conditions. The PhysioDroid system provides ubiquitous and continuous vital signs analysis, such as electrocardiogram, heart rate, respiration rate, skin temperature, and body motion, intended to help empower patients and improve clinical understanding. The PhysioDroid is composed of a wearable monitoring device and an Android app providing gathering, storage, and processing features for the physiological sensor data. The versatility of the developed app allows its use for both average users and specialists, and the reduced cost of the PhysioDroid puts it at the reach of most people. Two exemplary use cases for health assessment and sports training are presented to illustrate the capabilities of the PhysioDroid. Next technical steps include generalization to other mobile platforms and health monitoring devices.

  15. [Genotoxic damage among artisanal and small-scale mining workers exposed to mercury].

    Science.gov (United States)

    Rosales-Rimache, Jaime A; Elizabeth Malca, Nancy; Alarcón, Jhonatan J; Chávez, Manuel; Gonzáles, Marco Antonio

    2013-01-01

    To determine the genotoxic damage among artisanal and small-scale mining workers exposed to mercury. Observational cross-sectional study which evaluated mercury-exposed workers (n=83), whose cells were collected by mouth swab for further staining, microscopic observance, micronuclei count, and other nuclear alterations. 24-hour urine was also collected for the determination of inorganic mercury. 68.7% of participants were male, the mean age being 43 ± 12,4 years (range: 16-76). The average time of occupational exposure to mercury was 12,1 ± 6,7 years, and the contact with mercury was 4,1 ± 3,6 kg per person per day. 93% of participants failed to wear personal protection gear while handling mercury. Results of biological monitoring showed that 17% of participants had concentrations of mercury in urine higher than 2,5 µg/L, this value being the detection limit of the measurement technique used. Results of the genotoxic evaluation evidenced that 15% of people with labor exposure to mercury presented micronuclei in mouth epithelial cells, and other indicators of nuclear alteration such as nucleoplasmic bridges, gemmation and binucleation were found, which are also considered genotoxic events associated to the exposure of physical or chemical risk agents. The finding of micronuclei in mouth epithelial cells reflects genotoxic damage associated to the labor exposure of mercury used in artisanal and small-scale mining activities.

  16. Design and construction of a personal radiation monitor

    International Nuclear Information System (INIS)

    Oliveira, A.H. de.

    1979-01-01

    The design and construction of a personal radiation monitor is dealt with. It provides a direct and reliable reading of the received dose, and sounds an alarm in the event of an excessive dose rate. A detailed analysis of its design, construction and caracteristics is given, as well a comparison with usual dosimeters. The apparatus is based on large-scale integrated electronics, it is reliable, easy to read, and can be used in the same manner as a film-badge. Contrariwise to both the film-badge and the termoluminescent dosimeters, it allows a direct reading. Also, it is not susceptible to false readings due to mechanical shocks, which is the weak point of the pocket ionization chamber. The dosimeter described herein is equipped with a special corrective shield that gives the correct dose reading, regardless of the photon energy. It is also highly immune to neutron interference. (Author) [pt

  17. A Model-Driven Framework to Develop Personalized Health Monitoring

    Directory of Open Access Journals (Sweden)

    Algimantas Venčkauskas

    2016-07-01

    Full Text Available Both distributed healthcare systems and the Internet of Things (IoT are currently hot topics. The latter is a new computing paradigm to enable advanced capabilities in engineering various applications, including those for healthcare. For such systems, the core social requirement is the privacy/security of the patient information along with the technical requirements (e.g., energy consumption and capabilities for adaptability and personalization. Typically, the functionality of the systems is predefined by the patient’s data collected using sensor networks along with medical instrumentation; then, the data is transferred through the Internet for treatment and decision-making. Therefore, systems creation is indeed challenging. In this paper, we propose a model-driven framework to develop the IoT-based prototype and its reference architecture for personalized health monitoring (PHM applications. The framework contains a multi-layered structure with feature-based modeling and feature model transformations at the top and the application software generation at the bottom. We have validated the framework using available tools and developed an experimental PHM to test some aspects of the functionality of the reference architecture in real time. The main contribution of the paper is the development of the model-driven computational framework with emphasis on the synergistic effect of security and energy issues.

  18. Personnel radiation monitoring by thermoluminescence dosimetry (1995-96)

    International Nuclear Information System (INIS)

    Daw Mi Cho Cho; Daw Yi Yi Khin; Daw San San; U Maung Maung Tin; Daw Hla Hla Win

    2001-01-01

    Personnel radiation monitoring which is the dose assessment of individual doses from external radiation received by radiation workers has been carried out by Thermoluminescence Dosimetry system consisting of a Vinten Toledo TLD reader, LiF dosimeters and associated equipment. The exposed TLD dosimeters were measured by TLD reader and the dose evaluation and dose registration were done on personal computer. Due to the records of 1995-96, most of the radiation workers complied with the permissible dose recommended by IAEA and ICRP 60. (author)

  19. Evaluation of chromosomal aberrations in radiologists and medical radiographers chronically exposed to ionising radiation

    International Nuclear Information System (INIS)

    Kasuba, V.; Rozgaj, R.; Jazbec, A.

    2005-01-01

    Chromosomal aberrations are fairly reliable indicators of damage induced by ionising radiation. This study included 180 radiologists and medical radiographers (technicians) and 90 controls who were not occupationally exposed to ionising radiation. All exposed subjects were routinely monitored with film badge, and none was exposed to a radiation dose exceeding the limit for occupational exposure recommended by the International Commission on Radiological Protection (ICRP). Two hundred metaphases for each person were scored. The frequencies of acentric fragments, dicentrics, ring chromosomes and chromosomal exchanges were determined and compared to those obtained in the control group. Chromosome aberrations were analysed using Poisson regression for profession, age, sex, smoking and years of exposure. Age, smoking, diagnostic exposure to X-rays and occupation were found to correlate with the occurrence of acentric fragments. The influence of exposure duration on the frequency of acentric fragments was greater in medical radiographers than in radiologists. Smoking and sex were found to correlate with the occurrence of dicentric chromosomes, which were more common in men than in women. As chromosome aberrations exceeded the expected level with respect to the absorbed dose, our findings confirm the importance of chromosome analysis as a part of regular medical check-up of subjects occupationally exposed to ionising radiation.(author)

  20. Proposal and application of methodology for monitoring workers occupationally exposed to Thorium-232 and its decay products

    International Nuclear Information System (INIS)

    Dantas, Bernardo Maranhao

    1993-08-01

    Thorium-232 is the parent of one of the naturally occurring decay series and is widely spread on the earth's crust, being also present in higher concentrations at some deposits located mainly in Brazil and India. The occupational exposure to this radionuclide may occur in several steps of the thorium cycle. In Brazil, there is a large number of workers that should be monitored because they manipulate directly or indirectly different kinds of ores, raw materials and products containing significant amounts of thorium in its composition. In this study, the techniques developed specifically for the in vivo and in vitro monitoring of these workers are presented together with the application of these techniques to a group of selected workers classified as occupationally exposed. It is also presented the methodology by which the results obtained with these measurements are interpreted with the objective of identifying the main pathways of incorporation and reducing the internal doses to values as low as reasonably achievable. (author)

  1. Immunotoxicity Monitoring in a Population Exposed to Polychlorinated Biphenyls

    Directory of Open Access Journals (Sweden)

    Hajo Haase

    2016-03-01

    Full Text Available The relationship between polychlorinated biphenyl (PCB burden and several indicators of immune function was investigated as part of the HELPcB (Health Effects in High-Level Exposure to PCB program, offering bio-monitoring to workers, relatives, and neighbors exposed to PCBs by a German transformers and capacitors recycling company. The present retrospective observational study evaluates the correlation of plasma levels of total PCBs, five indicator congeners (28, 101, 138, 153, 180, and seven dioxin-like congeners (105, 114, 118, 156, 157, 167, 189 with several parameters of immune function. The cross-sectional study was performed immediately after the end of exposure (258 subjects, and one (218 subjects, and two (177 subjects years later. At the first time point, measurements showed significant positive correlation between congeners with low to medium chlorination and the relative proportion of CD19 positive B-cells among lymphocytes, as well as a negative correlation of PCB114 with serum IgM, and of PCB 28 with suppressor T-cell and NK-cell numbers. Congeners with a high degree of chlorination, in particular PCB157 and 189, were positively associated with expression of the activation marker CD25 on T-cells in the cohort of the second time point. No associations between PCB levels and IFN-y production by T-cells and killing by NK-cells were found. In conclusion, there were several effects on the cellular composition of adaptive immunity, affecting both T- and B-cells. However, the values were not generally outside the reference ranges for healthy adult individuals and did not indicate overt functional immunodeficiency, even in subjects with the uppermost PCB burden.

  2. Evaluating the interplay between spirituality, personality and stress.

    Science.gov (United States)

    Labbé, Elise E; Fobes, Ashley

    2010-06-01

    Spirituality and the big five personality traits may be risk or protective factors for coping with stress. We hypothesized young adults who reported higher spirituality ratings would demonstrate lower sympathetic nervous system arousal and better emotional coping when exposed to a laboratory stressor compared to those who rated themselves lower in spirituality. We also compared spirituality groups on trait anger, neuroticism, conscientiousness, extraversion, agreeableness and openness to experience. Eighty participants completed trait-state anger, personality and spirituality questionnaires and were grouped into low, average and high spirituality. Participants' physiological responses were monitored before and during a stressful event. Significant differences were found between low, average and high spirituality groups' respiration rate and emotional response to the stressor. Significant differences were also found between spirituality groups in extraversion, agreeableness, conscientiousness, trait anger and neuroticism. Females reported higher levels of spirituality and conscientiousness than males.

  3. Effects of Personal Protective Equipment Use and Good Workplace Hygiene on Symptoms of Neurotoxicity in Solvent-Exposed Vehicle Spray Painters.

    Science.gov (United States)

    Keer, Sam; McLean, Dave; Glass, Bill; Douwes, Jeroen

    2018-03-12

    To assess the association between the use of personal protective equipment (PPE) and good workplace hygiene and symptoms of neurotoxicity in solvent-exposed vehicle spray painters. Exposure control measures including PPE-use and workplace hygiene practices and symptoms of neurotoxicity were assessed in 267 vehicle repair spray painters. Symptoms were assessed using an adapted version of the EUROQUEST Questionnaire. Frequent respirator and glove use was inversely and significantly associated with symptoms of neurotoxicity in a dose-dependent manner (P 80%. Poor hygiene workplace practices, such as solvent exposure to multiple body parts (OR 3.4, P = 0.11 for reporting ≥10 symptoms), were associated with an increased risk of symptoms. When using a general workplace hygiene score derived from a combination of PPE-use and (good) workplace practice factors an inverse and significant dose-response trend was observed for reporting ≥5 (P hygiene are associated with a strongly reduced risk of symptoms of neurotoxicity in solvent-exposed vehicle spray painters.

  4. A cost-effective technique for integrating personal radiation dose assessment with personal gravimetric sampling

    International Nuclear Information System (INIS)

    Strydom, R.; Rolle, R.; Van der Linde, A.

    1992-01-01

    During recent years there has been an increasing awareness internationally of radiation levels in the mining and milling of radioactive ores, including those from non-uranium mines. A major aspect of radiation control is concerned with the measurement of radiation levels and the assessment of radiation doses incurred by individual workers. Current techniques available internationally for personnel monitoring of radiation exposures are expensive and there is a particular need to reduce the cost of personal radiation monitoring in South African gold mines because of the large labour force employed. In this regard the obvious benefits of integrating personal radiation monitoring with existing personal monitoring systems already in place in South African gold mines should be exploited. A system which can be utilized for this purpose is personal gravimetric sampling. A new cost-effective technique for personal radiation monitoring, which can be fully integrated with the personal gravimetric sampling strategy being implemented on mines, has been developed in South Africa. The basic principles of this technique and its potential in South African mines are described. 9 refs., 7 figs

  5. Design and application of a web-based real-time personal PM2.5 exposure monitoring system.

    Science.gov (United States)

    Sun, Qinghua; Zhuang, Jia; Du, Yanjun; Xu, Dandan; Li, Tiantian

    2018-06-15

    Growing demand from public health research for conduct large-scale epidemiological studies to explore health effect of PM 2.5 was well-documented. To address this need, we design a web-based real-time personal PM 2.5 exposure monitoring system (RPPM2.5 system) which can help researcher to get big data of personal PM 2.5 exposure with low-cost, low labor requirement, and low operating technical requirements. RPPM2.5 system can provide relative accurate real-time personal exposure data for individuals, researches, and decision maker. And this system has been used in a survey of PM 2.5 personal exposure level conducted in 5 cities of China and has provided mass of valuable data for epidemiological research. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Dosimetry service participation of CIEMAT in intercomparisons 2008-2010 for personal dosimeters EURADOS; Participacion del servicio de dosimetria del CIEMAT en las intercomparaciones EURADOS 2008-2010 para dosimetros personales

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Jimenez, R.; Romero Gutierrez, A. M.; Lopez Moyano, J. L.

    2011-07-01

    Individual monitoring of workers exposed to ionizing radiation requires the use of personal dosimeters. EURADOS (European Radiation Dosimetry Group) recently organized three intercomparison exercises External Personal Dosimetry Services (EPDS): two for body dosimeters in 2008 and 2010 and one for extremity dosimeters in the year 2009.El paper shows and analyzes the results obtained by CIEMAT SDPE participation in all exercises.

  7. Personal discovery in diabetes self-management: Discovering cause and effect using self-monitoring data.

    Science.gov (United States)

    Mamykina, Lena; Heitkemper, Elizabeth M; Smaldone, Arlene M; Kukafka, Rita; Cole-Lewis, Heather J; Davidson, Patricia G; Mynatt, Elizabeth D; Cassells, Andrea; Tobin, Jonathan N; Hripcsak, George

    2017-12-01

    To outline new design directions for informatics solutions that facilitate personal discovery with self-monitoring data. We investigate this question in the context of chronic disease self-management with the focus on type 2 diabetes. We conducted an observational qualitative study of discovery with personal data among adults attending a diabetes self-management education (DSME) program that utilized a discovery-based curriculum. The study included observations of class sessions, and interviews and focus groups with the educator and attendees of the program (n = 14). The main discovery in diabetes self-management evolved around discovering patterns of association between characteristics of individuals' activities and changes in their blood glucose levels that the participants referred to as "cause and effect". This discovery empowered individuals to actively engage in self-management and provided a desired flexibility in selection of personalized self-management strategies. We show that discovery of cause and effect involves four essential phases: (1) feature selection, (2) hypothesis generation, (3) feature evaluation, and (4) goal specification. Further, we identify opportunities to support discovery at each stage with informatics and data visualization solutions by providing assistance with: (1) active manipulation of collected data (e.g., grouping, filtering and side-by-side inspection), (2) hypotheses formulation (e.g., using natural language statements or constructing visual queries), (3) inference evaluation (e.g., through aggregation and visual comparison, and statistical analysis of associations), and (4) translation of discoveries into actionable goals (e.g., tailored selection from computable knowledge sources of effective diabetes self-management behaviors). The study suggests that discovery of cause and effect in diabetes can be a powerful approach to helping individuals to improve their self-management strategies, and that self-monitoring data can

  8. Personal digital assistants are comparable to traditional diaries for dietary self-monitoring during a weight loss program.

    Science.gov (United States)

    Yon, Bethany A; Johnson, Rachel K; Harvey-Berino, Jean; Gold, Beth Casey; Howard, Alan B

    2007-04-01

    Dietary self-monitoring is considered the core of behavioral weight control programs. As software for personal digital assistants (PDA) has become more available, this study investigated whether the use of a PDA would improve dietary self-monitoring frequency and subsequent weight loss over the use of traditional paper diaries. One-hundred-seventy-six adults (BMI 25-39.9) participated in a 6-month behavioral weight control program. Treatment subjects (n = 61) were provided with a PalmZire 21 with Calorie King's Diet Diary software installed. Their self-monitoring habits and weight loss were compared with the results from a previous program (n = 115) which followed the same protocol using paper diaries for self-monitoring. No significant differences in weight loss or dietary self-monitoring were found. More frequent self-monitoring correlated with weight loss in both groups (pself-monitoring that is fitting to their lifestyle and skills.

  9. Influence of Personal Factors on Sound Perception and Overall Experience in Urban Green Areas. A Case Study of a Cycling Path Highly Exposed to Road Traffic Noise.

    Science.gov (United States)

    Aletta, Francesco; Van Renterghem, Timothy; Botteldooren, Dick

    2018-05-30

    In contemporary urban design, green public areas play a vital role. They have great societal value, but if exposed to undue environmental noise their restorative potential might be compromised. On the other hand, research has shown that the presence of greenery can moderate noise annoyance in areas with high sound levels, while personal factors are expected to play an important role too. A cycling path bordered by vegetation, but highly exposed to road traffic noise, was here considered as a case study. A sound perception survey was submitted to participants on site and they were subsequently sorted into groups according to their noise sensitivity, visual attention and attitude towards greenery. The aim of this study was testing whether these three personal factors could affect their noise perception and overall experience of the place. Results showed that people highly sensitive to noise and more sceptical towards greenery's potential as an environmental moderator reported worse soundscape quality, while visually attentive people reported better quality. These three personal factors were found to be statistically independent. This study shows that several person-related factors impact the assessment of the sound environment in green areas. Although the majority of the respondents benefit from the presence of visual green, policy-makers and planners should be aware that for a significant subset of the population, it should be accompanied by a tranquil soundscape to be fully appreciated.

  10. Evaluation of the implementation and use of active personal dosimeters for neutrons in Brazil

    International Nuclear Information System (INIS)

    Castro B, C. P.; Wagner P, W.; De Souza P, K. C.

    2014-08-01

    This work was conducted through of a field research based on a questionnaire sent to users of active personal dosimeters. A retrospective study of the last six years was also carried out of the services in the Neutron Metrology Laboratory (2008-2013) referent to the active personal dosimeters, taking into consideration the standards ISO-8529-3 and IEC-61526. The active personal dosimeters are defined as any instrument of individual monitoring with direct reading capacity, used by individuals exposed to ionizing radiation fields. Through research was verified that the active personal dosimeters work associated with other dosimeter types. Considering all dosimeters declared in the questionnaire, only two dosimeters (MGP brand Dmc 2000-GN model and the brand ATOMTEX model AT2503A) have conformity declaration with the international standard IEC-61526: 2005 reported by the manufacturers. (author)

  11. Cytogenetic studies in persons, professionally exposed to low doses ionizing radiation

    International Nuclear Information System (INIS)

    Bulanova, M.; Ivanov, B.; Khristova, M.; Praskova, L.; Mikhajlov, M.; Dovev, I.

    1981-01-01

    Cytogenetic techniques were used to examine peripheral lymphocytes taken from 33 subjects employed at the IRT-2000-Sofia Nuclear Reactor and exposed to mixed gamma and neutron radiation in its Zone A. Physical dosimetry data (from pen and film personnel dosimeters) showed the exposures to be below maximum permissible levels, in complience with Radiation Safety Norms in the P.R. of Bulgaria (1972). The subjects were distributed into three groups according to the length of their occupational experience as radiation workers. Comparisons were made with cytogenetic findings in the lymphocyte cultures taken from 30 subjects with no occupational radiation exposure. Radiation workers exhibited a significant increase in chromosomal damage of the chromosome and chromatid type. Subjects with 5-10 years of occupational experience had a higher degree of chromosomal damage than the less-than-5-years group. For persons with more than 10 years of occupational experience, however, no increase over controls could be ascertained in percentage of chromosomal damage. When radiation workers were re-distributed in accord with the exposures received, it was evident that the effect increased with the accumulated dose, the group with about 0.02 Sievert having nearly twice the aberrant cell percentage for the 0.01 Sievert group. In the group of up to 0.05 Sievert, the percentage of aberrant cells was in the order of that observed after exposure to 0.02 Sievert. From the findings in the analysis, radiation quality seemed to play no part in enliciting the cytogenetic response of peripheral lymphocytes. (A.B.)

  12. Chromosome aberration analysis in persons exposed to low-level radiation from the JCO criticality accident in Tokai-mura

    International Nuclear Information System (INIS)

    Sasaki, Masao S.; Hayata, Isamu; Kamada, Nanao; Kodama, Yoshiaki; Kodama, Seiji

    2001-01-01

    Chromosome aberrations were studied in peripheral blood lymphocytes of 43 persons who were exposed to low-level radiation of mixed neutrons and γ-rays resulting from the JCO criticality accident. When the age-adjusted frequencies of dicentric and ring chromosomes were compared with the dose calibration curve established in vitro for 60 Co γ-rays as a reference radiation, a significant correlation was observed between the chromosomally estimated doses and the documented doses evaluated by physical means. The regression coefficient of the chromosomal doses against the documented doses, 1.47±0.33, indicates that the relative biological effectiveness of fission neutrons at low doses is considerably higher than that currently adopted in the radiation protection standard. (author)

  13. Contraceptive efficacy of the personal hormone monitoring system Persona.

    Science.gov (United States)

    Trussell, J

    1999-07-01

    This is a commentary on the contraceptive effectiveness of the personal hormone-monitoring system Persona; it points out the various errors committed in computing method pregnancy rates. The modifications presented by Bonnar et al. on the incorrect procedure for computing method pregnancy rates are criticized as erroneous because the denominator includes cycles in which there is no risk of a method pregnancy according to the authors' algorithm for classifying pregnancy in an imperfect-use cycle. It is also claimed that the new exercise is a more complicated and less accurate way of computing for pregnancy rates by comparison with the simpler alternative. Since this new algorithm, used in the Persona system, is based on flawed logic, the annual risk of pregnancy is actually higher than the estimated 6% among women using Persona and having intercourse in each cycle except on red days.

  14. Power levels in office equipment: Measurements of new monitors and personal computers

    International Nuclear Information System (INIS)

    Roberson, Judy A.; Brown, Richard E.; Nordman, Bruce; Webber, Carrie A.; Homan, Gregory H.; Mahajan, Akshay; McWhinney, Marla; Koomey, Jonathan G.

    2002-01-01

    Electronic office equipment has proliferated rapidly over the last twenty years and is projected to continue growing in the future. Efforts to reduce the growth in office equipment energy use have focused on power management to reduce power consumption of electronic devices when not being used for their primary purpose. The EPA ENERGY STAR[registered trademark] program has been instrumental in gaining widespread support for power management in office equipment, and accurate information about the energy used by office equipment in all power levels is important to improving program design and evaluation. This paper presents the results of a field study conducted during 2001 to measure the power levels of new monitors and personal computers. We measured off, on, and low-power levels in about 60 units manufactured since July 2000. The paper summarizes power data collected, explores differences within the sample (e.g., between CRT and LCD monitors), and discusses some issues that arise in m etering office equipment. We also present conclusions to help improve the success of future power management programs.Our findings include a trend among monitor manufacturers to provide a single very low low-power level, and the need to standardize methods for measuring monitor on power, to more accurately estimate the annual energy consumption of office equipment, as well as actual and potential energy savings from power management

  15. Medical status of Marshallese accidentally exposed to 1954 Bravo fallout radiation: January 1980-December 1982

    International Nuclear Information System (INIS)

    Adams, W.H.; Harper, J.A.; Rittmaster, R.S.; Heotis, P.M.; Scott, W.A.

    1984-01-01

    This report updates, for 1980 through 1982, the results of continuing medical surveillance of a Marshallese population accidentally exposed to radioactive fallout in March 1954. The originally exposed Marshallese population comprised 64 persons on Rongelap Atoll who each received, on the average, an estimated 190 rads of absorbed external gamma radiation, 18 on Ailingnae Atoll who received 110 rads, and 159 on Utirik who received 11 rads. There were, in addition, 3 persons in utero on Rongelap, 1 person in utero on Ailingnae, and 8 persons in utero on Utirik who are considered exposed. The recipients of primary medical care include exposed and comparison populations as well as a rather large number of additional beneficiaries who are seen on a humanitarian basis of practical need and resource availability. In recent years, about 1400 people have been seen annually. This report, however, deals with four clearly defined groups: the remaining individuals who were exposed to radioactive fallout on Rongelap, Ailingnae, and Utirik in 1954 (including those in utero), and a comparison population of individuals from Rongelap who were unexposed. The number of persons now in each exposure category are 51, 12, 116, and 137, respectively. 100 references, 4 figures, 5 tables

  16. Medical status of Marshallese accidentally exposed to 1954 Bravo fallout radiation: January 1980-December 1982

    Energy Technology Data Exchange (ETDEWEB)

    Adams, W.H.; Harper, J.A.; Rittmaster, R.S.; Heotis, P.M.; Scott, W.A.

    1984-01-01

    This report updates, for 1980 through 1982, the results of continuing medical surveillance of a Marshallese population accidentally exposed to radioactive fallout in March 1954. The originally exposed Marshallese population comprised 64 persons on Rongelap Atoll who each received, on the average, an estimated 190 rads of absorbed external gamma radiation, 18 on Ailingnae Atoll who received 110 rads, and 159 on Utirik who received 11 rads. There were, in addition, 3 persons in utero on Rongelap, 1 person in utero on Ailingnae, and 8 persons in utero on Utirik who are considered exposed. The recipients of primary medical care include exposed and comparison populations as well as a rather large number of additional beneficiaries who are seen on a humanitarian basis of practical need and resource availability. In recent years, about 1400 people have been seen annually. This report, however, deals with four clearly defined groups: the remaining individuals who were exposed to radioactive fallout on Rongelap, Ailingnae, and Utirik in 1954 (including those in utero), and a comparison population of individuals from Rongelap who were unexposed. The number of persons now in each exposure category are 51, 12, 116, and 137, respectively. 100 references, 4 figures, 5 tables. (ACR)

  17. Assessment of radiation emitted by the colour video monitors using a silicon surface-barrier detection system

    International Nuclear Information System (INIS)

    Tykva, R.; Sabol, J.

    1998-01-01

    About 5% of the commonly used colour monitors tested showed radiation levels on the screen surface approaching the dose rate of 5 μGy/h. There is practically no difference between 'low radiation' monitors and other monitors. The level of radiation emitted to the sides is generally higher than that of X-ray photons emerging from the surface of the screen. Although the contribution to the effective dose of a person exposed to radiation from the monitors may be below the limit set for the general public, the skin and eye lens dose may reach significant levels, taking into account some factors such as a high density of monitors in small rooms, short distance, long exposure time, etc. (M.D.)

  18. Reproductive toxicity parameters and biological monitoring in occupationally and environmentally boron-exposed persons in Bandirma, Turkey.

    Science.gov (United States)

    Duydu, Yalçın; Başaran, Nurşen; Üstündağ, Aylin; Aydin, Sevtap; Ündeğer, Ülkü; Ataman, Osman Yavuz; Aydos, Kaan; Düker, Yalçın; Ickstadt, Katja; Waltrup, Britta Schulze; Golka, Klaus; Bolt, Hermann M

    2011-06-01

    Boric acid and sodium borates have been considered as being "toxic to reproduction and development", following results of animal studies with high doses. Experimentally, a NOAEL (no observed adverse effect level) of 17.5 mg B/kg-bw/day has been identified for the (male) reproductive effects of boron in a multigeneration study of rats, and a NOAEL for the developmental effects in rats was identified at 9.6 mg B/kg-bw/day. These values are being taken as the basis of current EU safety assessments. The present study was conducted to investigate the reproductive effects of boron exposure in workers employed in boric acid production plant in Bandirma, Turkey. In order to characterize the external and internal boron exposures, boron was determined in biological samples (blood, urine, semen), in workplace air, in food, and in water sources. Unfavorable effects of boron exposure on the reproductive toxicity indicators (concentration, motility, morphology of the sperm cells and blood levels of follicle-stimulating hormone (FSH), luteinizing hormone (LH), and total testosterone) were not observed. The mean calculated daily boron exposure (DBE) of the highly exposed group was 14.45 ± 6.57 (3.32-35.62) mg/day. These human exposures represent worst-case exposure conditions to boric acid/borates in Turkey. These exposure levels are considerably lower than exposures, which have previously led to reproductive effects in experimental animals. In conclusion, this means that dose levels of boron associated with developmental and reproductive toxic effects in animals are by far not reachable for humans under conditions of normal handling and use.

  19. Personal monitoring services available at Institute for Radiation Protection of ENEA

    International Nuclear Information System (INIS)

    Fantuzzi, E.; Bonarelli, T.

    1999-01-01

    Personnel monitoring provides the means to measure and record the radiation doses received by individual workers. The ionising radiation decree (230/95) set out the circumstances when the assessment and recording of person's exposure is legally required. Many employers issue dosemeters to staff even though there is no legal requirement to do so. This may be part of a quality assurance programme or as a reassurance measure. Dosemeter readings will serve to ensure compliance with legal dose limits and assure the employer that radiation exposure is as low as reasonably achievable. The ENEA (National Agency for New Technology, Energy and the Environment) IRP (Institute for Radiation Protection) individual monitoring service has been running for over 30 years. It offers personnel dosemeters which are based on its expertise and backed up by continual research and development. The report provides details of the dosemeters in use at IRP enable to decide which ones most suit the needs and shows IMS's organisation, customer and communications, dose reports form and administrative items. A short mention of future development will also be given [it

  20. Personal dosimetry TLD 100 in orthopedic surgeons exposed to ionizing radiation in Bogota - Colombia; Dosimetria personal TLD 110 en medicos ortopedistas expuestos a radiacion ionizante en Bogota - Colombia

    Energy Technology Data Exchange (ETDEWEB)

    Sierra C, B. Y.; Jimenez, Y. [Universidad Nacional de Colombia, Departamento de Fisica, Grupo de Fisica Medica, Carrera 45 No. 26-85, Bogota (Colombia); Plazas, M. C. [Hospital Universitario Fundacion Santa Fe de Bogota, Instituto de Oncologia Carlos Ardila Lulle, Calle 119, No. 7-90, 220246 Bogota (Colombia); Eslava S, J. [Universidad Nacional de Colombia, Instituto de Investigaciones Clinicas, Grupo Equidad en Salud, Carrera 45 No. 26-85, Bogota (Colombia); Groot R, H., E-mail: brigith.sierra@gmail.com [Universidad de los Andes, Laboratorio de Genetica Humana, Carrera 1 No. 18A -12, Bogota (Colombia)

    2014-08-15

    Orthopedic surgeons should be considered as professionals occupationally exposed to ionizing radiation, for using C arc (fluoroscope) an equipment of X type radiation emission, during surgical procedures for imaging generation. Some health institutes, use of C arc under uncontrolled circumstances, such a lack of dosimetry control, incomplete or absence of personnel protective elements and protective measures, which in turn, lead to a high exposition to the personnel. Materials and methods. Study of double match cohort by age and gender, was conducted, in four health institutions of second and third level of attention in Bogota city. Personal dosimetry measurements with TLD-100 dosimetry crystals in both cohorts and environmental dosimetry in each of operation rooms used for orthopedic procedures, were carry out during six months of follow up. Dosimetry crystals were read in a Harshaw 4500 - Bicron equipment, in the Medical Physics Laboratory of National University of Colombia. Results. Dosimetry measurements are compatibles with those of occupationally exposed personnel 3.44 mSv/6 m CI 95% (1.66-3.99), even does not overpass ICRP recommendations, are higher as were expect at the beginning of the study. The median of effective accumulative dose in thorax is 3,4 mSv CI 95% (1,66-3,99), higher in comparison with neck value 2,7 mSv CI 95% (1,73-3,80) and hand dosimetry 1,42 mSv CI 95% (0,96-2,34). Conclusions: Orthopedic surgeons should be considered occupational exposed to ionizing radiation, who has to accomplish to the radiological protection measures, dosimetric follow up and maintenance of the used X ray equipment. It was confirm throughout this study that dosimetry shows higher levels as expected at the beginning of the study, compatible with occupationally exposed personnel. (Author)

  1. Cytogenetic monitoring of hospital workers exposed to low-level ionizing radiation

    International Nuclear Information System (INIS)

    Bigatti, P.; Lamberti, L.; Ardito, G.; Armellino, F.

    1988-01-01

    In the present study the cytogenetic effects in hospital workers exposed to low-level radiation were evaluated. Samples of peripheral blood were collected from 63 subjects working in radiodiagnostics and from 30 subjects, working in the same hospitals, who were used as controls. A higher number of cells with chromosome-type aberrations (CA) was observed in the exposed workers vs. the controls and the difference was statistically significant (p<0.05). No correlation was, on the contrary, found between CA and years of exposure. A significant difference was observed in the incidence of cells with CA between smokers and non-smokers, but in the control group only. In contrast, in the workers exposed to ionizing radiation, the frequency of cells with CA was very similar in smokers and non-smokers. 13 refs.; 4 tabs

  2. Integrating smart-phone based momentary location tracking with fixed site air quality monitoring for personal exposure assessment.

    Science.gov (United States)

    Su, Jason G; Jerrett, Michael; Meng, Ying-Ying; Pickett, Melissa; Ritz, Beate

    2015-02-15

    Epidemiological studies investigating relationships between environmental exposures from air pollution and health typically use residential addresses as a single point for exposure, while environmental exposures in transit, at work, school or other locations are largely ignored. Personal exposure monitors measure individuals' exposures over time; however, current personal monitors are intrusive and cannot be operated at a large scale over an extended period of time (e.g., for a continuous three months) and can be very costly. In addition, spatial locations typically cannot be identified when only personal monitors are used. In this paper, we piloted a study that applied momentary location tracking services supplied by smart phones to identify an individual's location in space-time for three consecutive months (April 28 to July 28, 2013) using available Wi-Fi networks. Individual exposures in space-time to the traffic-related pollutants Nitrogen Oxides (NOX) were estimated by superimposing an annual mean NOX concentration surface modeled using the Land Use Regression (LUR) modeling technique. Individual's exposures were assigned to stationary (including home, work and other stationary locations) and in-transit (including commute and other travel) locations. For the individual, whose home/work addresses were known and the commute route was fixed, it was found that 95.3% of the time, the individual could be accurately identified in space-time. The ambient concentration estimated at the home location was 21.01 ppb. When indoor/outdoor infiltration, indoor sources of air pollution and time spent outdoors were taken into consideration, the individual's cumulative exposures were 28.59 ppb and 96.49 ppb, assuming a respective indoor/outdoor ratio of 1.33 and 5.00. Integrating momentary location tracking services with fixed-site field monitoring, plus indoor-outdoor air exchange calibration, makes exposure assessment of a very large population over an extended time period

  3. The peculiarities of sexual development of children with clinical manifestations of insulin and leptin resistance born from the persons exposed in the childhood to radiation due to Chornobyl accident

    International Nuclear Information System (INIS)

    Kopilova, O.V.; Stepanenko, O.A.; Tsvjet, L.O.; Matsyuk, Yi.V.

    2010-01-01

    The purpose of the study was to reveal the peculiarities of sexual development of the children with clinical manifestations of insulin and leptin resistance born from the persons who were exposed to radiation after Chornobyl accident in their childhood. The study involved 108 persons aged 12-14. The findings of the investigation demonstrated changes in the central and peripheral links of neurohumoral regulation disorders of thyroid metabolism, changes in menstrual cycle development.

  4. Influence of Personal Factors on Sound Perception and Overall Experience in Urban Green Areas. A Case Study of a Cycling Path Highly Exposed to Road Traffic Noise

    Directory of Open Access Journals (Sweden)

    Francesco Aletta

    2018-05-01

    Full Text Available In contemporary urban design, green public areas play a vital role. They have great societal value, but if exposed to undue environmental noise their restorative potential might be compromised. On the other hand, research has shown that the presence of greenery can moderate noise annoyance in areas with high sound levels, while personal factors are expected to play an important role too. A cycling path bordered by vegetation, but highly exposed to road traffic noise, was here considered as a case study. A sound perception survey was submitted to participants on site and they were subsequently sorted into groups according to their noise sensitivity, visual attention and attitude towards greenery. The aim of this study was testing whether these three personal factors could affect their noise perception and overall experience of the place. Results showed that people highly sensitive to noise and more sceptical towards greenery’s potential as an environmental moderator reported worse soundscape quality, while visually attentive people reported better quality. These three personal factors were found to be statistically independent. This study shows that several person-related factors impact the assessment of the sound environment in green areas. Although the majority of the respondents benefit from the presence of visual green, policy-makers and planners should be aware that for a significant subset of the population, it should be accompanied by a tranquil soundscape to be fully appreciated.

  5. Personalized and automated remote monitoring of atrial fibrillation.

    Science.gov (United States)

    Rosier, Arnaud; Mabo, Philippe; Temal, Lynda; Van Hille, Pascal; Dameron, Olivier; Deléger, Louise; Grouin, Cyril; Zweigenbaum, Pierre; Jacques, Julie; Chazard, Emmanuel; Laporte, Laure; Henry, Christine; Burgun, Anita

    2016-03-01

    Remote monitoring of cardiac implantable electronic devices is a growing standard; yet, remote follow-up and management of alerts represents a time-consuming task for physicians or trained staff. This study evaluates an automatic mechanism based on artificial intelligence tools to filter atrial fibrillation (AF) alerts based on their medical significance. We evaluated this method on alerts for AF episodes that occurred in 60 pacemaker recipients. AKENATON prototype workflow includes two steps: natural language-processing algorithms abstract the patient health record to a digital version, then a knowledge-based algorithm based on an applied formal ontology allows to calculate the CHA2DS2-VASc score and evaluate the anticoagulation status of the patient. Each alert is then automatically classified by importance from low to critical, by mimicking medical reasoning. Final classification was compared with human expert analysis by two physicians. A total of 1783 alerts about AF episode >5 min in 60 patients were processed. A 1749 of 1783 alerts (98%) were adequately classified and there were no underestimation of alert importance in the remaining 34 misclassified alerts. This work demonstrates the ability of a pilot system to classify alerts and improves personalized remote monitoring of patients. In particular, our method allows integration of patient medical history with device alert notifications, which is useful both from medical and resource-management perspectives. The system was able to automatically classify the importance of 1783 AF alerts in 60 patients, which resulted in an 84% reduction in notification workload, while preserving patient safety. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  6. Novel use of a noninvasive hemodynamic monitor in a personalized, active learning simulation.

    Science.gov (United States)

    Zoller, Jonathan K; He, Jianghua; Ballew, Angela T; Orr, Walter N; Flynn, Brigid C

    2017-06-01

    The present study furthered the concept of simulation-based medical education by applying a personalized active learning component. We tested this novel approach utilizing a noninvasive hemodynamic monitor with the capability to measure and display in real time numerous hemodynamic parameters in the exercising participant. Changes in medical knowledge concerning physiology were examined with a pre-and posttest. Simply by observation of one's own hemodynamic variables, the understanding of complex physiological concepts was significantly enhanced. Copyright © 2017 the American Physiological Society.

  7. Radiation protection and environmental monitoring in the area of the Asse shaft plant

    International Nuclear Information System (INIS)

    Meyer, H.; Mueller-Lyda, I.

    1990-08-01

    Personnel monitoring has been carried through in compliance with the Radiation Protection Ordinance. Environmental monitoring including measurement of local doses, local dose rates, and airborne radioactivity in the shaft has been made according to the provisions for radiation protection at the place of work. Maximum permissible personal doses or activity levels for occupationally exposed persons have not been exceeded in the reporting period. Exhaust air monitoring detected the nuclides H-3, C-14, Pb-210, and the short-lived daughter products of Rn-222 and Rn-220. The activity concentrations in the environment, determined from the measured annual release values, for some part have been lower than the average of natural concentrations of said nuclides. The radiation exposure due to emissions, measured at the least favourable point in the environment, has been far below the limits set by the Radiation Protection Ordinance. In conclusion: The radiation exposure of the personnel and of the population in the area of the Asse shaft plant due to the storage of radioactive is low, compared to the natural radiation exposure. (orig.) [de

  8. Radiation protection and environmental monitoring in the area of the Asse shaft plant

    International Nuclear Information System (INIS)

    Mueller-Lyda, I.; Meyer, H.

    1989-06-01

    Personnel monitoring has been carried through in compliance with the Radiation Protection Ordinance. Environmental monitoring including measurement of local doses, local dose rates, and airborne radioactivity in the shaft has been made according to the provisions for radiation protection at the place of work. Maximum permissible personal doses or activity levels for occupationally exposed persons have not been exceeded in the reporting period. Exhaust air monitoring detected the nuclides H-3, C-14, Pb-210, and the short-lived daughter products of Rn-222 and Rn-220. The activity concentrations in the environment, determined from the measured annual release values, for some part have been lower than the average of natural concentrations of said nuclides. The radiation exposure due to emissions, measured at the least favourable point in the environment, has been far below the limits set by the Radiation Protection Ordinance. In conclusion: The radiation exposure of the personnel and of the population in the area of the Asse shaft plant due to the storage of radioactive is low, compared to the natural radiation exposure. (orig.) [de

  9. Personal exposure to benzene from fuel emissions among commercial fishers: comparison of two-stroke, four-stroke and diesel engines.

    Science.gov (United States)

    Kirrane, Ellen; Loomis, Dana; Egeghy, Peter; Nylander-French, Leena

    2007-03-01

    Commercial fishers are exposed to unburned hydrocarbon vapors and combustion products present in the emissions from their boat engines. The objective of this study was to measure personal exposure to benzene as a marker of fuel exposure, and to predict exposure levels across categories of carbureted two-stroke, four-stroke and diesel engines. A self-monitoring approach, employing passive monitors, was used to obtain measurements of personal exposure to benzene over time. Mixed-effect linear regression models were used to predict exposure levels, identify significant effects and determine restricted maximum likelihood estimates for within- and between-person variance components. Significant fixed effects for engine type and refueling a car or truck were identified. After controlling for refueling, predicted benzene exposure levels to fishers on boats equipped with two-stroke, four-stroke and diesel engines were 58.4, 38.9 and 15.7 microg/m3, respectively. The logged within-person variance component was 1.43, larger than the between-person variance component of 1.13, indicating that the total variation may be attributable to monitor placement, environmental conditions and other factors that change over time as well as differences between individual work practices. The health consequences of exposure to marine engine emissions are not known. The predicted levels are well below those at which health effects have been attributed, however.

  10. Pesticide monitoring in surface water and groundwater using passive samplers

    Science.gov (United States)

    Kodes, V.; Grabic, R.

    2009-04-01

    Passive samplers as screening devices have been used within a czech national water quality monitoring network since 2002 (SPMD and DGT samplers for non polar substances and metals). The passive sampler monitoring of surface water was extended to polar substances, in 2005. Pesticide and pharmaceutical POCIS samplers have been exposed in surface water at 21 locations and analysed for polar pesticides, perfluorinated compounds, personal care products and pharmaceuticals. Pesticide POCIS samplers in groundwater were exposed at 5 locations and analysed for polar pesticides. The following active substances of plant protection products were analyzed in surface water and groundwater using LC/MS/MS: 2,4,5-T, 2,4-D, Acetochlor, Alachlor, Atrazine, Atrazine_desethyl, Azoxystrobin, Bentazone, Bromacil, Bromoxynil, Carbofuran, Clopyralid, Cyanazin, Desmetryn, Diazinon, Dicamba, Dichlobenil, Dichlorprop, Dimethoat, Diuron, Ethofumesate, Fenarimol, Fenhexamid, Fipronil, Fluazifop-p-butyl, Hexazinone, Chlorbromuron, Chlorotoluron, Imazethapyr, Isoproturon, Kresoxim-methyl, Linuron, MCPA, MCPP, Metalaxyl, Metamitron, Methabenzthiazuron, Methamidophos, Methidathion, Metobromuron, Metolachlor, Metoxuron, Metribuzin, Monolinuron, Nicosulfuron, Phorate, Phosalone, Phosphamidon, Prometryn, Propiconazole, Propyzamide, Pyridate, Rimsulfuron, Simazine, Tebuconazole, Terbuthylazine, Terbutryn, Thifensulfuron-methyl, Thiophanate-methyl and Tri-allate. The POCIS samplers performed very well being able to provide better picture than grab samples. The results show that polar pesticides and also perfluorinated compounds, personal care products and pharmaceuticals as well occur in hydrosphere of the Czech republic. Acknowledgment: Authors acknowledge the financial support of grant No. 2B06095 by the Ministry of Education, Youth and Sports.

  11. Dosimetry of Occupationally Exposed Persons in Diagnostic and Interventional Arteriography. Part 1: Assessment of Entrance Doses

    International Nuclear Information System (INIS)

    Kicken, P.J.H.; Kemerink, G.J.; Engelshoven, J.M.A. van

    1999-01-01

    The purpose of this study was to obtain representative quantitative information on exposure conditions and entrance doses of occupationally exposed persons (workers) in diagnostic and interventional arteriography. In a study in three hospitals all parameters of the X ray systems that are related to the exposure of workers were quantified with an automatic data acquisition system. Using LiF thermoluminescence dosemeters, entrance doses to workers were measured at the forehead, neck, thorax, abdomen, upper arms, hands and lower legs. Measurements were performed during 353 procedures, and it was found that exposure of workers was predominantly caused by fluoroscopy. Averaged over all procedures in the annual workload, entrance doses were below 120 μGy when an undercouch X ray tube and a mechanical contrast injector were used. For an overcouch tube the doses were higher. It is concluded that entrance doses are low, and that legally established annual dose limits are un-likely to be exceeded. (author)

  12. Lymphocytic reactions in persons occupationally exposed to ionizing radiation

    International Nuclear Information System (INIS)

    Bliznakov, V.; Nikolov, A.

    1989-01-01

    The most frequent reasons for deviations of hematological indicies in radiological and X-ray personnel are discussed. The dynamics of lymphocyte count in individuals working in the city of Sofia is tabulated for a period of 12 years. The data show that the number of deviations from the norm (accepted as 1.929±0.908 g/l) reduced in time, which is one of the features of radiation syndrome. 24.23% of the persons investigated have had lymphocytosis. The following most common reasons for this are mentioned: increased cummulative radiation dose, focal infections, alergie, neurosis, tyreotoxicosis, virus infections, leucosis. The second and third investigations of such persons before applying any therapy are proposed in order to precisize the diagnosting

  13. The performance of passive flow monitors and phosphate accumulating passive samplers when exposed to pulses in external water flow rate and/or external phosphate concentrations

    International Nuclear Information System (INIS)

    O'Brien, Dominique; Hawker, Darryl; Shaw, Melanie; Mueller, Jochen F.

    2011-01-01

    Passive samplers are typically calibrated under constant flow and concentration conditions. This study assessed whether concentration and/or flow pulses could be integrated using a phosphate passive sampler (P-sampler). Assessment involved three 21-day experiments featuring a pulse in flow rate, a pulse of filterable reactive phosphate (FRP) concentration and a simultaneous concentration and flow pulse. FRP concentrations were also determined by parallel grab sampling and the P-sampler calibrated with passive flow monitors (PFMs) and direct measurement of flow rates. The mass lost from the PFM over the deployment periods predicted water velocity to within 5.1, 0.48 and 7.1% when exposed to a flow rate pulse (7.5-50 cm s -1 ), concentration pulse (5-100 μg P L -1 ), or both simultaneously. For the P-sampler, good agreement was observed between the grab and passive measurements of FRP concentration when exposed to a pulse in flow (6% overestimation) or concentration (2% underestimation). - Highlights: → We assess the performance of the passive flow monitor and a phosphate passive sampler when exposed to changing environmental conditions. → The PFM responded quickly and accurately to a pulse in flow rate but showed little response to an external FRP pulse. → The ability of the sampler to provide an integrated measure of the average phosphate concentrations has been demonstrated. → The results presented demonstrate under which conditions the greatest accuracy is achieved when employing passive samplers. - The performance of an integrative phosphate passive sampler has been assessed when exposed to pulses in flow rate and concentration, both individually and simultaneously.

  14. Monitoring of genotoxic effects in lymphocytes of people exposed to pesticides

    International Nuclear Information System (INIS)

    Panek, A.; Marcos, R.; Cebulska-Wasilewska, A.

    2002-01-01

    The aim of this study was to assess the potential genotoxic risk of occupational exposure to pesticides. The DNA damage and the repair capacities of lymphocytes, in four groups of the people of various countries were assessed by the use of single cell gel electrophoresis (SCGE) also known as the Comet assay. The results from the analysis performed in the Spanish group are presented in this paper. Statistical analysis of the results shows a slightly higher level of the DNA damage in the untreated lymphocytes of donors from the group exposed to pesticides; however, only for donors below 30 years old are these differences significant (p<0.05). Although, comparison of the efficiency of the UV-C induced dimmers excision process did not indicate differences between exposed and referent groups, though lymphocytes for donors exposed to pesticides have shown a statistically lower repair rate (p<0.01) than lymphocytes from the unexposed group. (author)

  15. Personalized professional content recommendation

    Science.gov (United States)

    Xu, Songhua

    2015-10-27

    A personalized content recommendation system includes a client interface configured to automatically monitor a user's information data stream transmitted on the Internet. A hybrid contextual behavioral and collaborative personal interest inference engine resident to a non-transient media generates automatic predictions about the interests of individual users of the system. A database server retains the user's personal interest profile based on a plurality of monitored information. The system also includes a server programmed to filter items in an incoming information stream with the personal interest profile and is further programmed to identify only those items of the incoming information stream that substantially match the personal interest profile.

  16. The design of a miniature personal exposure monitor for continuous real-time data acquisition in electromagnetic field exposure assessment

    International Nuclear Information System (INIS)

    Hansen, N.H.; Conroy, T.J.; Wilson, B.W.

    1994-06-01

    The design of a small, light-weight personal exposure monitor suitable for use in EMF exposure assessment studies is nearing completion at Pacific Northwest Laboratory. The monitor is designed to be non-obtrusive, battery operated, and able to continuously record extremely low-frequency (ELF) (1Ohz--500hz) magnetic-field data. It also captures high-frequency (500hz--1OMhz) transients that exceed a preset threshold, retaining the largest transients in memory. The monitor can record one or more days of data on a single easily replaceable, credit-card-size memory (PCMCIA). A battery charge will last a minimum of one day. Batteries are rechargeable and easily replaced. A data-compression algorithm is under development that will be tailored to the efficient compression of low-frequency EMF signals and will permit data to be logged for at least one day before swapping memory cards. The memory cards are readable by a base- station computer that can perform analysis of the data. The monitor is designed to accommodate four inputs supporting full-field sensors as well as a proposed ocular exposure measurement system. Our design effort has shown that a practical personal exposure monitor for EMF can be built based on current technology, continuous logging of real-time ELF waveforms is both feasible and practical, and such a device is appropriate for proposed EMF exposure studies

  17. Quantitative Determination of Serum Proteins in Persons Occupationally Exposed to Radar

    International Nuclear Information System (INIS)

    Kasuba, V.; Garaj-Vrhovac, V.

    1998-01-01

    Radio-wave communications are used extensively in the modern society. We are all subject to radio frequency radiation (RFR) created by a radio, television, wireless telephony, emergency communications, and radar. The interest in the health effects of RFR has been motivated the rapid growth in wireless communications. Recently, many investigations are headed to the influence of nonionizing electromagnetic radiation to people. The interpretation of nonionizing radiation effects depends on apsorption characteristics of biological material and on thermoregulative system of exposed persons. This article includes serum protein analysis of 14 people who work in a radar zone. All the examinees are men aged 39 in average. The average exposure period in the radar zone was 16 years (twelve hours each second day). Human serum proteins in all samples were detected by electrophoresis on cellulose acetate membranes (Cellogel 500, Chemeton, Italy) in sodium-Veronal-Veronal-TRIS buffer pH 8.6. The duration of electrophoresis was two hours at 130-140 V at 11 cm bridge. Electroferograms were stained with 0.1 % Ponceau,s (w/v) (Chemetron, Italy) in 5% trichloracetic acid (v/v). Quantitative determination, i.e. densitometry of five serum protein fractions (albumin, α 1 - , α 2 - , β 1 - and γ -globulin) was carried out by photometry at multipolar densitometer. The results show gradual decrease of albumin 58.0 - 44.0 g/l versus control (64.05 g/l), except in three examinees where the values were almost equal to the normal value. One can also observe the changes in γ -globulin levels. All examinees except one showed increase in g -globulin levels (19.0 - 30.0 g/l vs. normal 15.0 g/l). The effect of nonionizing electromagnetic and microwave radiation on those who work in related field certainly needs much more investigation. (author)

  18. Development of the Nation-Wide Dosimetric Monitoring Network in Ukraine

    International Nuclear Information System (INIS)

    Chumak, V.; Boguslavskaya, A.; Musijachenko, A.

    2004-01-01

    Development of the nation-wide network for monitoring and registration of individual doses is being in progress in Ukraine. The need for urgent action is caused by the fact, that despite wide use of nuclear energy and radiation sources in industry and medicine, there is no centralized dose accounting system in Ukraine, existing dosimetry services operate obsolete manual TLD readers and no methodological unity is observed by the dosimetry services. Presently the mixed dosimetric monitoring is practiced in Ukraine. Nuclear power plants and some major nuclear facilities have their own dosimetry services responsible for dosimetric monitoring of workers. Rest of occupationally exposed persons is monitored by territorial dosimetry laboratories affiliated to sanitary and epidemiology supervision bodies. In total these services cover about 38,000 occupationally exposed workers, including 5,500 in medicine, 16,400 employees of five nuclear power plants and about 16,000 workers dealing with other sources of occupational exposure (industry, research, military). It is prescribed by the governmental decree that three-level united state system assigned to covering all aspects of efficient dosimetric monitoring should be established. The tasks of the system, in particular, are: securing methodical unity of individual dosimetric monitoring; scientific and methodological guidance of individual dosimetric control; procurement of common technical policy regarding nomenclature and operation of instrumentation; implementation of quality assurance programs; development and support of information infrastructure for logging, storage and access to data on individual dosimetric monitoring, in particular - keeping the national registry of individual doses; training and certification of personnel engaged in the system of individual dosimetric monitoring. In its development, the national system will be guided by international experience and will be established according to the best practices

  19. The system of personal monitoring and the evaluation of occupational exposure to external ionizing radiation in Cuba

    International Nuclear Information System (INIS)

    Molina, Daniel; Castro, Ailza; Martinez, Ernesto; Pernas, Rene

    2008-01-01

    Full text: Personal monitoring of workers is recommended or required by the International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources. In our country the personal monitoring of external exposure to ionizing radiation is carried out by External Dosimetry Laboratory (LDE) of the Center for Radiation Protection and Hygiene (CPHR). We have implemented an individual monitoring service based on thermoluminescence dosimetry system. The service includes whole body and extremity dosimeters. We have two systems; one is base on a manual Toledo TLD reader and the other on an automatic RADOS TLD system. This service is recognized by the National Regulatory Authority in the field of radiation protection and safety. We have implemented a quality assurance (QA) programme designed according to the recommendations of the ISO/IEC 17025 standards. The papers deals with the presentation of these QA programme which includes administrative data and information, technical checking of the equipment, acceptance tests of new dosimeters and equipment, issuing and processing of the dosimeters, dose evaluation, record keeping and reporting, traceability, handling of complaints, internal reviews and external audits. The papers also describe the results of occupational exposure for the different practices during 2006-2007 period. (author)

  20. The personal dosimetry in Mexico

    International Nuclear Information System (INIS)

    Salazar, M.A.

    2006-01-01

    The Personal Dosimetry in Mexico, has an approximately 30 year-old history; and it had been and it is at the moment, one of the more important resources with which the personnel that works with ionizing radiation sources counts for its protection. The Personal Dosimetry begins with the film dosimetry, technique that even continues being used at the present time by some users, and the main reason of its use is for economic reasons. At the moment this technique, it has been surpassed, by the Thermoluminescent dosimetry, which has taken a lot of peak, mainly by the technological development with which it is counted at the present time; what has given as a result that this technique becomes tip technology; that supported in the characteristic of the used materials, as the handling and processing of the information associated with the new PC, digitizer cards, software etc, what has allowed increases it potential. In this work the current necessities of the market are presented as well as an analysis of the future real necessities in Mexico, at national level, the companies that provide this service and that they spread to satisfy this necessity of the market, including the different used technologies are also mentioned. The application ranges, at the same time, of the advantages and disadvantages of the different systems of Personal Dosimetry in the market. The companies that at the moment provide the service of Personal Dosimetry, its use materials and equipment in indistinct form, for the monitoring of gamma radiation, beta particles, different qualities of x-ray radiation, and sometimes neutrons. The monitoring of the exposed personnel at the diverse sources of ionizing radiation mentioned is carried out in many occasions without having with the materials (detectors), neither the appropriate infrastructure and therefore without the quality control that guarantees a correct evaluation of the dose equivalent, as a result of the exposure to the ionizing radiations; it

  1. Age-dependent dose factors and dose limits of annual radioactivity uptake with unsealed radioactive substances by occupationally exposed persons

    International Nuclear Information System (INIS)

    Kaul, A.; Nosske, D; Elsasser, U; Roedler, H.D.; Henrichs, K.

    1986-01-01

    The dose factors have been calculated on the basis of the ICRP models for dosimetric and metabolistic assessment, and are laid open in accordance with Annex XI ( to sec. 45 sub-section (2)) of the amended version of the Radiation Protection Ordinance. The contribution in hand explains the scientific fundamentals and results of the calculations of dose factors relating to inhalation and ingestion of unsealed radioactive substances by adult reference man, and age-dependent factors calculated for children and adolescents. Further, annual limits of uptake by occupationally exposed persons, as calculated on the basis of primary dose limits pursunant to the draft amendment presented by the Federal Interior Minister, are compared with relevant data given by the ICRP and EC institutions. (orig./DG) [de

  2. [Personal computer-based computer monitoring system of the anesthesiologist (2-year experience in development and use)].

    Science.gov (United States)

    Buniatian, A A; Sablin, I N; Flerov, E V; Mierbekov, E M; Broĭtman, O G; Shevchenko, V V; Shitikov, I I

    1995-01-01

    Creation of computer monitoring systems (CMS) for operating rooms is one of the most important spheres of personal computer employment in anesthesiology. The authors developed a PC RS/AT-based CMS and effectively used it for more than 2 years. This system permits comprehensive monitoring in cardiosurgical operations by real time processing the values of arterial and central venous pressure, pressure in the pulmonary artery, bioelectrical activity of the brain, and two temperature values. Use of this CMS helped appreciably improve patients' safety during surgery. The possibility to assess brain function by computer monitoring the EEF simultaneously with central hemodynamics and body temperature permit the anesthesiologist to objectively assess the depth of anesthesia and to diagnose cerebral hypoxia. Automated anesthesiological chart issued by the CMS after surgery reliably reflects the patient's status and the measures taken by the anesthesiologist.

  3. Comparison of Respirable Mass Concentrations Measured by a Personal Dust Monitor and a Personal DataRAM to Gravimetric Measurements.

    Science.gov (United States)

    Halterman, Andrew; Sousan, Sinan; Peters, Thomas M

    2017-12-15

    In 2016, the Mine Safety and Health Administration required the use of continuous monitors to measure respirable dust in mines and better protect miner health. The Personal Dust Monitor, PDM3700, has met stringent performance criteria for this purpose. In a laboratory study, respirable mass concentrations measured with the PDM3700 and a photometer (personal DataRam, pDR-1500) were compared to those measured gravimetrically for five aerosols of varying refractive index and density (diesel exhaust fume, welding fume, coal dust, Arizona road dust (ARD), and salt [NaCl] aerosol) at target concentrations of 0.38, 0.75, and 1.5 mg m-3. For all aerosols except coal dust, strong, near-one-to-one, linear relationships were observed between mass concentrations measured with the PDM3700 and gravimetrically (diesel fume, slope = 0.99, R2 = 0.99; ARD, slope = 0.98, R2 = 0.99; and NaCl, slope = 0.95, R2 = 0.99). The slope deviated substantially from unity for coal dust (slope = 0.55; R2 = 0.99). Linear relationships were also observed between mass concentrations measured with the pDR-1500 and gravimetrically, but one-to-one behavior was not exhibited (diesel fume, slope = 0.23, R2 = 0.76; coal dust, slope = 0.54, R2 = 0.99; ARD, slope = 0.61, R2 = 0.99; NaCl, slope = 1.14, R2 = 0.98). Unlike the pDR-1500, mass concentrations measured with the PDM3700 appear independent of refractive index and density, suggesting that it could have applications in a variety of occupational settings. © The Author(s) 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  4. Monitoring hprt mutant frequency over time in T-lymphocytes of people accidentally exposed to high doses of ionizing radiation

    International Nuclear Information System (INIS)

    Cruz, A.D. da; Curry, J.; Glickman, B.W.

    1996-01-01

    Modern technologies have provided the opportunity to monitor mutations in people in vivo. The subjects of this study were accidentally exposed to 137 Cesium in a radiological accident that occurred in September 1987 in Goiania, Brazil, during which more than 150 people received doses greater than 0.1 Gy and as high as 7 Gy. The objective of this study was to determine how long the hprt mutant T-cells in the peripheral blood contribute to mutant T-cells in the peripheral blood contribute to mutant frequency by examining the timecourse of the T-lymphocyte response to ionizing radiation. This report describes the results obtained over a period of 2.3 to 4.5 years subsequent to the accident, from 11 subjects with doses ranging from 1 to 7 Gy, and from nine control subjects selected from the same population. The mean In MF (±SE) of the control group was 2.5 (±0.2) + In10 -6 . The exposed group had a significantly increased mutant frequency; the mean ln MF (±SE) were 3.3 (±0.3) + In10 -6 , 2.8 (±0.2) + In10 -6 , and 2.3 (±0.2) + In10 -6 , in the years 1990-1992 respectively and using Buckton's models, we demonstrated that mutant T-cells have a short-term memory with a half-life of 2.1 years. This relatively short half-half limits the effective use of the hprt assay as the method of choice to monitor past exposure. The data also demonstrate a positive correlation with age, and an inverse correlation with plating efficiency. 77 refs., 3 figs., 4 tabs

  5. Temporal stability of blood lead concentrations in adults exposed only to environmental lead

    Energy Technology Data Exchange (ETDEWEB)

    Delves, H T; Sherlock, J C; Quinn, M J

    1984-08-01

    The temporal stability of blood lead concentrations of 21 health adults (14 men and 7 women) exposed only to environmental lead was assessed by analysis of 253 blood specimens collected serially over periods from 7 to 11 months. The women had lower blood lead concentrations (mean 8.5, range 7.4-10.8 micrograms/100 ml) than did the men (mean 12.2, range 8.6-15.8 micrograms/100 ml). These are within the expected ranges for non-occupationally exposed persons. Blood lead concentrations in the serial specimens from both men and women changed very little over the study period, with standard deviations of less than 0.5 micrograms/100 ml for the majority of individual mean concentrations: for all except low subjects the standard deviations were less than 0.8 micrograms/100 ml. Two subjects showed significant changes in blood lead concentrations during the study. A temporary increase in oral lead intake was identified for one of these subjects. In the absence of substantial changes in lead exposure blood lead levels in adults are remarkably stable and for their environmental monitoring a single blood lead concentration is an excellent biological indicator.

  6. Comparing personal alpha dosimetry with the conventional area monitoring-time weighting methods of exposure estimation: a Canadian assessment

    International Nuclear Information System (INIS)

    Balint, A.B.; Viljoen, J.

    1988-01-01

    An experimental personal alpha dosimetry program for monitoring exposures of uranium mining facility workers in Canada has been completed. All licenced operating mining facilities were participating. Dosimetry techniques, description of dosimeters used by licences, performance and problems associated with the implementation of the programme as well as technical and administrative advantages and difficulties experienced are discussed. Area monitoring-time weighting methods used and results obtained to determine individual radon and thoron daughter exposure and exposure results generated by using dosimeters are assessed and compared

  7. Accelerometry: A feasible method to monitor physical activity during sub-acute rehabilitation of persons with stroke.

    Science.gov (United States)

    Joseph, Conran; Strömbäck, Björn; Hagströmer, Maria; Conradsson, David

    2018-05-08

    To investigate the feasibility of using accelerometers to monitor physical activity in persons with stroke admitted to inpatient rehabilitation. Longitudinal observational study. Persons with stroke admitted to a specialized rehabilitation centre for sub-acute rehabilitation were recruited between August and December 2016. Volume and intensity of physical activity were assessed with accelerometers throughout the rehabilitation period. Indicators of feasibility included processes (recruitment, protocol adherence and participants' experiences) and scientific feasibility, which assessed the accelerometers' ability to detect change in physical activity among stroke survivors who ambulate independently and those who are dependent on a mobility device. Twenty-seven out of 31 eligible individuals took part in this study, with 23 (85%) completing it. In total, 432 days of rehabilitation were monitored and valid physical activity data were obtained for 408 days (94%). There were no indications that the measurement interfered with participants' ability to participate in rehabilitation. Despite the subjects' ambulation status, the number of steps and time spent in moderate-to-vigorous physical activity increased significantly across the first 18 days of rehabilitation, whereas sedentary time was unchanged. This study supports the feasibility of using accelerometers to capture physical activity behaviour in survivors of stroke during inpatient rehabilitation.

  8. Elevated urinary levels of kidney injury molecule-1 among Chinese factory workers exposed to trichloroethylene

    Science.gov (United States)

    Vermeulen, Roel; Huang, Hanlin; Rothman, Nathaniel; Lan, Qing

    2012-01-01

    Epidemiological studies suggest that trichloroethylene (TCE) exposure may be associated with renal cancer. The biological mechanisms involved are not exactly known although nephrotoxicity is believed to play a role. Studies on TCE nephrotoxicity among humans, however, have been largely inconsistent. We studied kidney toxicity in Chinese factory workers exposed to TCE using novel sensitive nephrotoxicity markers. Eighty healthy workers exposed to TCE and 45 comparable unexposed controls were included in the present analyses. Personal TCE exposure measurements were taken over a 2-week period before urine collection. Ninety-six percent of workers were exposed to TCE below the current US Occupational Safety and Health Administration permissible exposure limit (100 ppm 8h TWA), with a mean (SD) of 22.2 (35.9) ppm. Kidney injury molecule-1 (KIM-1) and Pi-glutathione S transferase (GST) alpha were elevated among the exposed subjects as compared with the unexposed controls with a strong exposure-response association between individual estimates of TCE exposure and KIM-1 (P < 0.0001). This is the first report to use a set of sensitive nephrotoxicity markers to study the possible effects of TCE on the kidneys. The findings suggest that at relatively low occupational exposure levels a toxic effect on the kidneys can be observed. This finding supports the biological plausibility of linking TCE exposure and renal cancer. Abbreviations:GSTglutathione-S-transferaseKIM-1kidney injury molecule-1NAGN-acetyl-beta-(d)-glucosaminidaseOVMorganic vapour monitoringTCEtrichloroethyleneVEGFvascular endothelial growth factor. PMID:22665366

  9. Evaluation of personal dose equivalent 'HP(d)' in a external individual monitoring system for X and gamma radiation

    International Nuclear Information System (INIS)

    Santoro, C.; Antonio Filho, J.; Santos, M.A.P.

    2007-01-01

    The good of individual monitoring for external radiation is the assessment of occupational exposure from X and γ radiations in order to assure that the radiological conditions of the workplace are acceptable, safe and satisfactory. The evaluation of radiations doses for workers must not exceed dose limits specified for workers, according to national regulatory agencies. Nowadays, there are two external monitoring systems in use, both based on ICRU definitions. In the conventional system, the workers doses are evaluated in terms of Hx. The personal dosimeter is worn over chest surface and it is calibrated in function of air kerma. In the new system, the workers doses are evaluated in terms of HP(d) and the personal dosimeter is calibrated in function of phantom doses. The aim of this paper is to adapt an external dosimetry laboratory (based on photographic dosimetry) to evaluate the personal dosimeters in terms of HP(d). In this way, a simple methodology, based on linear programming, was utilized. In this adaptation, calibration curves were obtained for radiation qualities (W and N series) described by International Organization for Standardization (ISO 4037-1, 1995). These calibration curves offer a better accuracy on dose determinations and energy below 140 keV, improving the quality of service rendered the society. (author)

  10. Individual internal monitoring of workers of Fabrica de Combustivel Nuclear - FCN

    International Nuclear Information System (INIS)

    Castro, Marcelo X.

    2005-01-01

    In nuclear fuel fabrication facilities, workers are exposed to different compounds of enriched uranium. Due to the high cost of the individual monitoring programme for internal dose assessment in the routine monitoring programmes, usually only one type of measurement is assigned. In complex situations like the one described in this paper, where several parameters can compromise the accuracy of the bioassay interpretation it is need to have a combination of techniques to evaluate the internal dose. According to ICRP 78 (1997), the general order of preference in terms of accuracy of interpretation is: body activity measurement, excreta analysis and personal air sampling. A group of fifteen workers from controlled area of the fuel fabrication facility was selected to evaluate the internal dose using all different available techniques during a certain period. The workers were monitored for determination of uranium content in the daily urinary excretion, faecal excretion, chest counting and personal air sampling (PAS). The results have shown that at least two types of sensitivity techniques must be used, since there are some sources of uncertainties on the bioassay interpretation, like mixture of uranium compounds intake and different routes of intake. The combination of urine and faeces analysis has shown be the more appropriate methodology for assessing internal dose in this situation. (author)

  11. A handbook for the triage, monitoring and treatment of people exposed to a malevolent use of radiation

    International Nuclear Information System (INIS)

    Rojas-Palma, Carlos; Meer, Klaas van der; Liland, Astrid; Jaworska, Alicja; Jerstad, Ane; Kruse, Phil; Smith, Karen; Rahola, Tua; Muikku, Maarit; Etherington, George; Perez, Maria del R.; Carr, Zhanat; Smagala, Genowefa

    2008-01-01

    In the aftermath of the Chernobyl accident European national emergency response plans have been tailored to deal with accidents at nuclear power plants. Several terrorist acts (World Trade Center, New York; Atocha train station, Madrid; suicide bombings) carried out by disaffected groups have shifted the focus to malevolent use of radiation. The radiation exposure can range from very low to substantial, possibly combined with conventional injuries. Therefore practicable tools are needed for an adequate response to such acts and more specifically to address European guidelines covering triage to treatment and long term follow up of exposed people. The European Commission through the EURATOM 6th Framework Programme is co-sponsoring the specific targeted research project TMT handbook. The main objective of this project is to produce a practicable handbook for the effective and timely triage, monitoring and treatment of people exposed to radiation following a malevolent act. This paper elaborates on the work being carried out and outlines the progress achieved prior to the deployment of the handbook in European national emergency response organizations, which are in the process of testing and evaluating the material through targeted emergency response exercises. The end of this paper includes some remarks on the challenges that need to be dealt with in order to achieve a sustainable development of what has been achieved through the lifetime of this project. (author)

  12. Cytogenetic study of in utero exposed individuals, 2

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Masahiro; Honda, Takeo

    1986-11-01

    In 20 persons exposed in uterus to atomic radiation, chromosomes in the peripheral lymphocytes were examined using G-band differential staining and conventional Giemsa staining techniques. The subjects were divided into Group A of the mothers receiving 17 - 535 rad and Group B of the mothers receiving 0 rad. Chromosome aberrations were observed in 72 (5%) of 1,463 cells in Group A and in 19 (1%) of 1503 cells in Group B. Most of the chromosome aberrations were stable type involving translocation, inversion, and deletion. In one person whose mother was exposed to 453 rad, structural chromosome aberrations were observed in 53 (38%) of 141 cells. Furthermore, 11 cells had two kinds of clones. This finding may provide clues for elucidating the promotion of cloning of cells with stable type structural chromosome aberrations due to in uterus exposure to high doses of atomic radiation. (Namekawa, K.).

  13. Cytogenetic study of in utero exposed individuals, 2

    International Nuclear Information System (INIS)

    Itoh, Masahiro; Honda, Takeo

    1986-01-01

    In 20 persons exposed in uterus to atomic radiation, chromosomes in the peripheral lymphocytes were examined using G-band differential staining and conventional Giemsa staining techniques. The subjects were divided into Group A of the mothers receiving 17 - 535 rad and Group B of the mothers receiving 0 rad. Chromosome aberrations were observed in 72 (5 %) of 1,463 cells in Group A and in 19 (1 %) of 1503 cells in Group B. Most of the chromosome aberrations were stable type involving translocation, inversion, and deletion. In one person whose mother was exposed to 453 rad, structural chromosome aberrations were observed in 53 (38 %) of 141 cells. Furthermore, 11 cells had two kinds of clones. This finding may provide clues for elucidating the promotion of cloning of cells with stable type structural chromosome aberrations due to in uterus exposure to high doses of atomic radiation. (Namekawa, K.)

  14. Review of personal monitoring techniques for the measurement of absorbed dose from external beta and low energy photon radiation

    DEFF Research Database (Denmark)

    Christensen, Poul

    1986-01-01

    The techniques available at present for personal monitoring of doses from external beta and low energy photon radiation are reviewed. The performance of currently used dosimetry systems is compared with that recommended internationally, and developments for improving the actual performance...

  15. Personal use of hair dyes and temporary black tattoos in Copenhagen hairdressers

    DEFF Research Database (Denmark)

    Hansen, Henriette S; Johansen, Jeanne D; Thyssen, Jacob P

    2010-01-01

    Hairdressers are occupationally and personally exposed to hair dye substances and adverse reactions from the skin are well known. Currently, little is known about personal exposure to hair dye ingredients and temporary black tattoos.......Hairdressers are occupationally and personally exposed to hair dye substances and adverse reactions from the skin are well known. Currently, little is known about personal exposure to hair dye ingredients and temporary black tattoos....

  16. The modulating effect of personality traits on neural error monitoring: evidence from event-related FMRI.

    Science.gov (United States)

    Sosic-Vasic, Zrinka; Ulrich, Martin; Ruchsow, Martin; Vasic, Nenad; Grön, Georg

    2012-01-01

    The present study investigated the association between traits of the Five Factor Model of Personality (Neuroticism, Extraversion, Openness for Experiences, Agreeableness, and Conscientiousness) and neural correlates of error monitoring obtained from a combined Eriksen-Flanker-Go/NoGo task during event-related functional magnetic resonance imaging in 27 healthy subjects. Individual expressions of personality traits were measured using the NEO-PI-R questionnaire. Conscientiousness correlated positively with error signaling in the left inferior frontal gyrus and adjacent anterior insula (IFG/aI). A second strong positive correlation was observed in the anterior cingulate gyrus (ACC). Neuroticism was negatively correlated with error signaling in the inferior frontal cortex possibly reflecting the negative inter-correlation between both scales observed on the behavioral level. Under present statistical thresholds no significant results were obtained for remaining scales. Aligning the personality trait of Conscientiousness with task accomplishment striving behavior the correlation in the left IFG/aI possibly reflects an inter-individually different involvement whenever task-set related memory representations are violated by the occurrence of errors. The strong correlations in the ACC may indicate that more conscientious subjects were stronger affected by these violations of a given task-set expressed by individually different, negatively valenced signals conveyed by the ACC upon occurrence of an error. Present results illustrate that for predicting individual responses to errors underlying personality traits should be taken into account and also lend external validity to the personality trait approach suggesting that personality constructs do reflect more than mere descriptive taxonomies.

  17. The modulating effect of personality traits on neural error monitoring: evidence from event-related FMRI.

    Directory of Open Access Journals (Sweden)

    Zrinka Sosic-Vasic

    Full Text Available The present study investigated the association between traits of the Five Factor Model of Personality (Neuroticism, Extraversion, Openness for Experiences, Agreeableness, and Conscientiousness and neural correlates of error monitoring obtained from a combined Eriksen-Flanker-Go/NoGo task during event-related functional magnetic resonance imaging in 27 healthy subjects. Individual expressions of personality traits were measured using the NEO-PI-R questionnaire. Conscientiousness correlated positively with error signaling in the left inferior frontal gyrus and adjacent anterior insula (IFG/aI. A second strong positive correlation was observed in the anterior cingulate gyrus (ACC. Neuroticism was negatively correlated with error signaling in the inferior frontal cortex possibly reflecting the negative inter-correlation between both scales observed on the behavioral level. Under present statistical thresholds no significant results were obtained for remaining scales. Aligning the personality trait of Conscientiousness with task accomplishment striving behavior the correlation in the left IFG/aI possibly reflects an inter-individually different involvement whenever task-set related memory representations are violated by the occurrence of errors. The strong correlations in the ACC may indicate that more conscientious subjects were stronger affected by these violations of a given task-set expressed by individually different, negatively valenced signals conveyed by the ACC upon occurrence of an error. Present results illustrate that for predicting individual responses to errors underlying personality traits should be taken into account and also lend external validity to the personality trait approach suggesting that personality constructs do reflect more than mere descriptive taxonomies.

  18. Neurophysiological evidence of impaired self-monitoring in schizotypal personality disorder and its reversal by dopaminergic antagonism

    OpenAIRE

    Mireia Rabella; Eva Grasa; Iluminada Corripio; Sergio Romero; Miquel Àngel Mañanas; Rosa Mª. Antonijoan; Thomas F. Münte; Víctor Pérez; Jordi Riba

    2016-01-01

    BACKGROUND: Schizotypal personality disorder (SPD) is a schizophrenia-spectrum disorder characterized by odd or bizarre behavior, strange speech, magical thinking, unusual perceptual experiences, and social anhedonia. Schizophrenia proper has been associated with anomalies in dopaminergic neurotransmission and deficits in neurophysiological markers of self-monitoring, such as low amplitude in cognitive event-related brain potentials (ERPs) like the error-related negativity (ERN), and the erro...

  19. Radiation protection and environmental monitoring in the area of the Asse shaft plant. Annual report 1987

    International Nuclear Information System (INIS)

    Mueller-Lyda, I.; Meyer, H.

    1988-07-01

    Personnel monitoring has been carried through in compliance with the Radiation Protection Ordinance. Environmental monitoring including measurement of local doses, local dose rates, and airborne radioactivity in the shaft has been made according to the provisions for radiation protection at the place of work. Maximum permissible personal doses or activity levels for occupationally exposed persons have not been exceeded in the reporting period. Exhaust air monitoring detected the nuclides H-3, C-14, Pb-210, and the short-lived daughter products of Rn-222 and Rn-220. The activity concentrations in the environment, determined from the measured annual release values, for some part have been lower than the average of natural concentrations of said nuclides. The radiation exposure due to emissions, measured at the least favourable point in the environment, has been far below the limits set by the Radiation Protection Ordinance. In conclusion: The radiation exposure of the personnel and of the population in the area of the Asse shaft plant due to the storage of radioactive is low, compared to the natural radiation exposure. (orig.) [de

  20. Trends in monitoring pharmaceuticals and personal-care products in the aquatic environment by use of passive sampling devices

    Science.gov (United States)

    Mills, G.A.; Vrana, B.; Allan, I.; Alvarez, D.A.; Huckins, J.N.; Greenwood, R.

    2007-01-01

    The use of passive sampling in monitoring pharmaceuticals and personal-care products (PPCPs) in the aquatic environment is discussed. The utility of passive sampling methods for monitoring the fraction of heavy metals and the biologically available fraction of non-polar organic priority pollutants is recognized and these technologies are being used in surveys of water quality. These devices are used to measure the dissolved fraction and they can yield information that can be used in the development of risk assessments models. These devices can also be used to locate illegal dumping and to monitor specific sources of input of PPCPs into the environment, or to monitor the effectiveness of water treatment processes in the removal of these compounds from wastewater. These devices can provide representative information at low cost which necessitate a combination of laboratory calibration and field studies for emerging pollutants.

  1. Monitoring personal budgets and restrictions

    NARCIS (Netherlands)

    Ab van der Torre; Ingrid Ooms; Mirjam de Klerk

    2013-01-01

    The personal budget is a sum of money which recipients can use to arrange and pay for their own care provider. Since its introduction, demand for this provision, which is funded through the Exceptional Medical Expenses Act (AWBZ) has grown rapidly, prompting the Dutch government to take a number

  2. First national intercomparison of personal dosimetry for dosimetry service providers in paec

    International Nuclear Information System (INIS)

    Akhter, J.; Ahmed, S.S.

    2006-12-01

    Health Physics Division, PINSTECH, has conducted an intercomparison exercise for PAEC organizations which are responsible for providing personal dosimetry services for the assessment of occupational doses of radiation workers. The exercise was on voluntary basis and it was designed to harmonize the procedure of individual dose monitoring techniques in terms of new ICRP operational quantities of personal dose equivalent Hp (10) for photons. Cobalt-60 and Cesium-137 protection level sources were used for irradiation. The dosimeters were exposed to radiation in the range of 0.46 to 24.20 mSv. Irradiations were performed in Secondary Standard Dosimetry Laboratory (SSDL) at HPD, PINSTECH according to IAEA/WHO standards. The performance of the participating laboratories was judged by trumpet curve that provides the acceptable limits on overall accuracy for occupational dose monitoring at 95% confidence level according to international standards. The response of measured dose/standard true dose (Hm/Ht lies in the range of 0.66 to 1.11 for 60CO and 0.84 to 1.17 for 137CS. This report describes the procedure and results of the intercomparison exercise. (author)

  3. Personalized Feedback on Staff Dose in Fluoroscopy-Guided Interventions: A New Era in Radiation Dose Monitoring.

    Science.gov (United States)

    Sailer, Anna M; Vergoossen, Laura; Paulis, Leonie; van Zwam, Willem H; Das, Marco; Wildberger, Joachim E; Jeukens, Cécile R L P N

    2017-11-01

    Radiation safety and protection are a key component of fluoroscopy-guided interventions. We hypothesize that providing weekly personal dose feedback will increase radiation awareness and ultimately will lead to optimized behavior. Therefore, we designed and implemented a personalized feedback of procedure and personal doses for medical staff involved in fluoroscopy-guided interventions. Medical staff (physicians and technicians, n = 27) involved in fluoroscopy-guided interventions were equipped with electronic personal dose meters (PDMs). Procedure dose data including the dose area product and effective doses from PDMs were prospectively monitored for each consecutive procedure over an 8-month period (n = 1082). A personalized feedback form was designed displaying for each staff individually the personal dose per procedure, as well as relative and cumulative doses. This study consisted of two phases: (1) 1-5th months: Staff did not receive feedback (n = 701) and (2) 6-8th months: Staff received weekly individual dose feedback (n = 381). An anonymous evaluation was performed on the feedback and occupational dose. Personalized feedback was scored valuable by 76% of the staff and increased radiation dose awareness for 71%. 57 and 52% reported an increased feeling of occupational safety and changing their behavior because of personalized feedback, respectively. For technicians, the normalized dose was significantly lower in the feedback phase compared to the prefeedback phase: [median (IQR) normalized dose (phase 1) 0.12 (0.04-0.50) µSv/Gy cm 2 versus (phase 2) 0.08 (0.02-0.24) µSv/Gy cm 2 , p = 0.002]. Personalized dose feedback increases radiation awareness and safety and can be provided to staff involved in fluoroscopy-guided interventions.

  4. [A survey of occupational health among polyether-exposed workers].

    Science.gov (United States)

    Fu, Xu-ying; Yu, Bin; Zhang, Chun-ping; Zheng, Guan-hua; Bai, Lan; Zhang, Pan-pan

    2013-06-01

    To investigate the occupational health of the workers simultaneously exposed to acrylonitrile, epoxyethane, epoxypropane, and styrene. A questionnaire survey was conducted in 70 front-line workers simultaneously exposed to acrylonitrile, epoxyethane, epoxypropane, and styrene (exposure group) and 50 managers (control group) in a polyether manufacturer; in addition, air monitoring at workplace and occupational health examination were also performed. The obtained data were analyzed. The female workers in exposure group and the spouses of male workers in exposure group had significantly higher spontaneous abortion rates than their counterparts in control group (P polyether-exposed working years had significantly higher mean levels of DNA damage than the control group (P polyether-exposed working years and those with not less than 20 polyether-exposed working years had significantly higher mean micronucleus rates than the control group (P polyether-exposed working years (P > 0.05); the workers with not less than 5 and less than 20 polyether-exposed working years and workers with not less than 20 polyether-exposed working years had significantly higher mean micronucleus rates than those with less than 5 polyether-exposed working years (P polyether manufacturer.

  5. Program of long term immunological monitoring of population groups exposed to risk factors due to Chernobyl accident

    International Nuclear Information System (INIS)

    Petrov, R.V.; Oradovskaya, I.V.; Pinegin, B.V.

    1991-01-01

    Program for long-term monitoring of health and immune status of people exposed to ionizing radiation during efforts to to eliminate effects of Chernobyl accident and those subjected to radiation factor effect linked with their living within the contanimated territories is considered. Program purpose consists in investigation into non-stochastic and stochastic immunological effects resulting from radiation factor effect under extreme conditions and under prolonged effect of low doses; in acquisition of new data on immune system state during early after the accident and delayed periods in people which took part in recovery efforts during the accident effect elimination and those who live within the controlled territories. Program is directed to early diagnostics of immune-depented pathologic states and other disfunctions of immunity during prenosologic period, and to development and conduction of combined preventive and treatment-and-sanitary measures using immunomodulation

  6. Occupational exposure to ultrafine particles among airport employees--combining personal monitoring and global positioning system

    DEFF Research Database (Denmark)

    Møller, Karina Lauenborg; Thygesen, Lau Caspar; Schipperijn, Jasper

    2014-01-01

    BACKGROUND: Exposure to ultrafine particles (UFP) has been linked to cardiovascular and lung diseases. Combustion of jet fuel and diesel powered handling equipment emit UFP resulting in potentially high exposure levels among employees working at airports. High levels of UFP have been reported...... at several airports, especially on the apron, but knowledge on individual exposure profiles among different occupational groups working at an airport is lacking. PURPOSE: The aim of this study was to compare personal exposure to UFP among five different occupational groups working at Copenhagen Airport (CPH......). METHOD: 30 employees from five different occupational groups (baggage handlers, catering drivers, cleaning staff and airside and landside security) at CPH were instructed to wear a personal monitor of particle number concentration in real time and a GPS device. The measurements were carried out on 8 days...

  7. Quality assurance in personal dosimetry of external radiation: present situation and future needs

    International Nuclear Information System (INIS)

    Ma, N.

    2006-01-01

    Whole body personal dosimetry is well established for the individual monitoring of radiation workers. High quality radiation dosimetry is essential for workers who rely upon personal dosemeters to record the amount of radiation to which they are exposed. The mandate has been given to the Personal Dosimetry, (secondary standard dosimetry laboratories) S.S.D.L., (Malaysian institute for nuclear energy research) M.I.N.T. to assure the individual monitoring for radiation workers in Malaysia. In 2005, the S.S.D.L;-M.I.N.T. supply, process and read out of personal dosemeters of nearly 13,000 dosimeters monthly, whereby. 12,000 are films and 1,000 are T.L.D.s. The objective of individual monitoring is not limited to the measurement of doses delivered to individuals, but it should demonstrate that limits of exposure have not been exceeded and that working conditions have not unexpectedly deteriorated. Dosimetry measurements are an important component of radiation protection programs and must be of high quality. The exposure of workers to radiation must be controlled and monitored in order to comply with regulatory requirements. S.S.D.L.-M.I.N.T; demonstrates that its performance is at an acceptable level by implementing overall system performance, as evidenced by the ISO 9001 certification of the Personal Dosimetry Service in 2002 and ISO/I.E.C. 17025 accreditation to the calibration laboratory in 2004. The certification and accreditation processes achieved the goal by formalizing the recognition of satisfactory performance, and providing evidence of this performance. Overall performances are assessed, personnel operating the system will be trained and are well qualified and all actions will be documented. The paper describes the overview of the Q.M.S. carried out at the S.S. D.L.-M.I.N.T.. During the implementation of Q.M.S. a few areas has been identified for future consideration. These include performance specification and type testing of dosemeters, which provide a

  8. A Wearable Wireless Sensor Network for Indoor Smart Environment Monitoring in Safety Applications.

    Science.gov (United States)

    Antolín, Diego; Medrano, Nicolás; Calvo, Belén; Pérez, Francisco

    2017-02-14

    This paper presents the implementation of a wearable wireless sensor network aimed at monitoring harmful gases in industrial environments. The proposed solution is based on a customized wearable sensor node using a low-power low-rate wireless personal area network (LR-WPAN) communications protocol, which as a first approach measures CO₂ concentration, and employs different low power strategies for appropriate energy handling which is essential to achieving long battery life. These wearables nodes are connected to a deployed static network and a web-based application allows data storage, remote control and monitoring of the complete network. Therefore, a complete and versatile remote web application with a locally implemented decision-making system is accomplished, which allows early detection of hazardous situations for exposed workers.

  9. A Wearable Wireless Sensor Network for Indoor Smart Environment Monitoring in Safety Applications

    Directory of Open Access Journals (Sweden)

    Diego Antolín

    2017-02-01

    Full Text Available This paper presents the implementation of a wearable wireless sensor network aimed at monitoring harmful gases in industrial environments. The proposed solution is based on a customized wearable sensor node using a low-power low-rate wireless personal area network (LR-WPAN communications protocol, which as a first approach measures CO2 concentration, and employs different low power strategies for appropriate energy handling which is essential to achieving long battery life. These wearables nodes are connected to a deployed static network and a web-based application allows data storage, remote control and monitoring of the complete network. Therefore, a complete and versatile remote web application with a locally implemented decision-making system is accomplished, which allows early detection of hazardous situations for exposed workers.

  10. Contamination of persons occupationally exposed to natural radioactivity in a coal fired power plant

    International Nuclear Information System (INIS)

    Bauman, A.; Horvat, D.

    1980-01-01

    Contamination of occupationally exposed subjects with natural radioactivity in a coal fired power plant at levels of 500 mrem/year was detected. The level of 210 Pb in urine varied from 2.29-14.47 pCi/l. These values were arrived at after subtracting a blank value of 1.05 pCi 210 Pb obtained from a control group. Structural chromosomal aberrations, completely missing in the control group, were detected in the exposed subjects. Approximately 6-10% of the metaphases of occupationally exposed subjects were found to have aberrations which were probably radiation induced. These included symmetrical and asymmetrical exchanges and numerical aberrations. In the control aroup aberrations were found in 1.4-4% of the metaphases, but these were only deletions. (H.K.)

  11. Studies of workers exposed to low doses of external radiation

    International Nuclear Information System (INIS)

    Gilbert, E.S.

    1991-04-01

    Currently, several epidemiologic studies of workers who have been exposed occupationally to low levels of radiation are being conducted, and include studies of workers in the United States, Great Britain, and Canada involved in the production of both defense materials and nuclear power. This paper focuses on studies that evaluate the possible adverse effects resulting from external exposure to radiation. The radiation risk estimates that have been used to establish radiation protection standards for workers and others have been obtained mainly from studies of persons exposed at high doses and dose rates. However, questions remain with regard to the extrapolation process that has been necessary for estimating low-level radiation risks. Occupational studies provide a direct assessment of risk based on data on persons exposed at the actual levels of interest. If current risk estimates are correct, these studies have very little chance of detecting risk, but can still be used to provide useful upper limits on risks. The studies are also adequate to detect serious underestimation of risks. 36 refs., 3 figs., 3 tabs

  12. Surveillance of health care workers exposed to ionising radiation: Rimed pilot study

    International Nuclear Information System (INIS)

    2008-01-01

    The project so-called RIMED aimed to set up epidemiological surveillance of health care workers exposed to ionizing radiation. A pilot study was conducted in a sample of hospital personnel to examine the possibility of identifying exposed subjects in order to analyse mortality patterns according to occupational characteristics such as medical departments or occupations in a historical cohort. Seven hospitals participated in this pilot study. Health-care workers who had worn a dosimeter up to December 2003 were to be included in this cohort. The subjects' identification data were obtained from the SISERI (Systeme d'information de la surveillance de l'exposition aux rayonnements ionisants - Ionizing Radiation Exposure Monitoring Information System) database managed by the Institut de radioprotection et de surete nucleaire - Radiation Protection and Nuclear Safety Institute (IRSN). The SISERI system was in a 'pilot' phase in 2004. According to SISERI database, a total of 5126 subjects were found to have worn a dosimeter up to December 2003. The subjects' identification data were completed by the administrative services of the hospitals and occupational physicians searched for subjects' occupational data. Information required for the vital status search was satisfactorily completed only for 38% of the cohort subjects. This pilot study showed that obtaining data from SISERI database completed by hospital administrative data in 2004 led to a database of insufficient quality for epidemiological surveillance. The Institut de veille sanitaire (French Institute of Public Health Surveillance) recommends that transmission by the employers of some specific personal or occupational data of the exposed subjects should be made compulsory. In this way, SISERI system should be able to constitute any database with required quality for epidemiological surveillance of ionizing radiation exposed subjects. (authors)

  13. A head-mounted display-based personal integrated-image monitoring system for transurethral resection of the prostate.

    Science.gov (United States)

    Yoshida, Soichiro; Kihara, Kazunori; Takeshita, Hideki; Fujii, Yasuhisa

    2014-12-01

    The head-mounted display (HMD) is a new image monitoring system. We developed the Personal Integrated-image Monitoring System (PIM System) using the HMD (HMZ-T2, Sony Corporation, Tokyo, Japan) in combination with video splitters and multiplexers as a surgical guide system for transurethral resection of the prostate (TURP). The imaging information obtained from the cystoscope, the transurethral ultrasonography (TRUS), the video camera attached to the HMD, and the patient's vital signs monitor were split and integrated by the PIM System and a composite image was displayed by the HMD using a four-split screen technique. Wearing the HMD, the lead surgeon and the assistant could simultaneously and continuously monitor the same information displayed by the HMD in an ergonomically efficient posture. Each participant could independently rearrange the images comprising the composite image depending on the engaging step. Two benign prostatic hyperplasia (BPH) patients underwent TURP performed by surgeons guided with this system. In both cases, the TURP procedure was successfully performed, and their postoperative clinical courses had no remarkable unfavorable events. During the procedure, none of the participants experienced any HMD-wear related adverse effects or reported any discomfort.

  14. Miniaturized inertial impactor for personal airborne particulate monitoring: Prototyping

    Science.gov (United States)

    Pasini, Silvia; Bianchi, Elena; Dubini, Gabriele; Cortelezzi, Luca

    2017-11-01

    Computational fluid dynamic (CFD) simulations allowed us to conceive and design a miniaturized inertial impactor able to collect fine airborne particulate matter (PM10, PM2.5 and PM1). We created, by 3D printing, a prototype of the impactor. We first performed a set of experiments by applying a suction pump to the outlets and sampling the airborne particulate of our laboratory. The analysis of the slide showed a collection of a large number of particles, spanning a wide range of sizes, organized in a narrow band located below the exit of the nozzle. In order to show that our miniaturized inertial impactor can be truly used as a personal air-quality monitor, we performed a second set of experiments where the suction needed to produce the airflow through the impactor is generated by a human being inhaling through the outlets of the prototype. To guarantee a number of particles sufficient to perform a quantitative characterization, we collected particles performing ten consecutive deep inhalations. Finally, the potentiality for realistic applications of our miniaturized inertial impactor used in combination with a miniaturized single-particle detector will be discussed. CARIPLO Fundation - project MINUTE (Grant No. 2011-2118).

  15. Influencing College Student Drinking Intentions With Social Norms and Self-Schema Matched Messages: Differences Between Low and High Self-Monitors.

    Science.gov (United States)

    Miller, Megan M; Brannon, Laura A

    2015-01-01

    College students were exposed to either a self-schema matched message (emphasizing how binge drinking is inconsistent with personal values) or a social norms message (highlighting the true normative drinking behavior of peers). As predicted, low self-monitors intended to drink significantly less alcohol if they received the self-schema matched message versus the social norms message, and high self-monitors intended to drink less if they received the social norms message versus a self-schema message. While previous research supports both techniques for marketing responsible college student drinking, the current results suggest that each method may be especially effective for certain audiences.

  16. The medical management of high risk individuals. Experiences with persons exposed to chronic internal irradiation; Ueber den aerztlichen Umgang mit Hochrisikopersonen. Erfahrungen bei Personen mit chronischer interner Strahlenexposition

    Energy Technology Data Exchange (ETDEWEB)

    Kaick, G. van; Delorme, S. [Deutsches Krebsforschungszentrum, E010 - Radiologie, Heidelberg (Germany)

    2011-12-15

    The medical management and counseling of persons at high risk due to exposure to chemicals or radiation or due to personal disposition, present an additional challenge for physicians and especially radiologists involved. This article is based on own experiences with patients who had been exposed to Thorotrast. They had been injected with the contrast medium Thorotrast, which was in use world-wide until around 1950. Thorotrast caused a chronic alpha irradiation mainly of the liver (up to 0.4 Gy/a), spleen (1.2 Gy/a) and bone marrow (0.1 Gy/a). For the Thorotrast patients and their physicians the most worrying problem was the risk of primary malignant liver tumors which occurred in more than 20% of the exposed persons, i.e. 100 times more frequently than in a non-exposed control group. The medical and especially radiological experiences with the management of these patients summarize a general aspect of the problem and can be referred to when managing other high risk groups. (orig.) [German] Die aerztliche Fuehrung von Personen, die noch nicht erkrankt sind, aber ein deutlich hoeheres Risiko fuer bestimmte Tumorerkrankungen aufgrund exogener oder endogener Ursachen haben, stellt den Arzt und speziell den diagnostischen Radiologen vor neue Herausforderungen. Dem Beitrag zugrunde liegen die Erfahrungen bei der Betreuung und Beratung so genannter Thorotrastpatienten, d. h. Personen, die nach lange zurueckliegender (vor 1950) intravasaler Injektion eines weltweit eingesetzten Roentgenkontrastmittels zeitlebens einer Alphastrahlung v. a. der Leber (bis 0,4 Gy/a), der Milz (1,2 Gy/a) und des Knochenmarks (0,1 Gy/a) ausgesetzt waren. Fuer die Thorotrastpatienten und die Aerzte stand im Vordergrund die Sorge der Entstehung primaerer, maligner Lebertumoren, die bei mehr als 20% der Betroffenen und damit im Vergleich zu einer Kontrollgruppe 100-fach haeufiger auftraten. Die allgemeinen aerztlichen und speziell radiologischen Erfahrungen sind grundsaetzlicher Art und lassen

  17. Status of calcium regulating hormonal systems in delayed period in persons exposed to occupational exposure of low doses of ionizing radiations

    International Nuclear Information System (INIS)

    Dospolova, Zh.G.; Abylaev, Zh.A.

    1997-01-01

    Purpose of study is consideration of endocrine system participation in development of calcium exchange disorders in persons exposed to action of low dose radiation . By radio- immune method in blood serum of 150 liquidators of Chernobyl accident consequences the concentration the following hormones were determined: parathormone, T 3 , T 4 , TSH, cortisol, ACTH, testosteron, insulin. Content of these hormones have been studied in according to following radiation factors: value of absorbed doses of external irradiation, degree of radioactive contamination of zone and exposition duration. It was determined, that basically dishormone disorders development have been concerned with parathormone, cortisol, hormones of thyroid axis, and in some cases to ACTH and insulin. Liquidators' frequencies of normal and changed concentration of calcium regulating hormones are sited in tabular form. It was established, that examined persons in result hormone disorders have of decrease functions of pituitary glands (76.78 %), pancreas (55 %), thyroid gland (24.31 %) and sex glands (19.23 %) and simultaneously cases of increase functions of parathyroid gland (58.2 %), adrenal glands (52.32 %) and adeno-pituitary glands (17.39). It is concluded, that inter hormonal correlation disorders are accompanying with morphologic and functional futures of secretory activity changes

  18. Personality and posttraumatic stress disorder among directly exposed survivors of the Oklahoma City bombing.

    Science.gov (United States)

    North, Carol S; Abbacchi, Anna; Cloninger, C Robert

    2012-01-01

    Few disaster studies have specifically examined personality in association with exposure to disaster and development of posttraumatic stress disorder (PTSD). A study of survivors of the Oklahoma City bombing examined PTSD and personality measured after the disaster. In a random sample of 255 survivors from a bombing survivor registry, 151 (59%) completed both full PTSD and personality assessments using the Diagnostic Interview Schedule and the Temperament and Character Inventory, respectively. Postbombing PTSD was associated with low self-directedness and low cooperativeness, and also with high self-transcendence and harm avoidance in most configurations. Disorganized (schizotypal) character and explosive (borderline) temperament configurations were associated with PTSD; creative and autocratic character configurations were negatively associated with PTSD. Clinicians should be vigilant for PTSD among individuals with personality disorders and also be aware that personality disorders are likely to be overrepresented among people with PTSD. Treatment of PTSD may need to take into account comorbid personality disorders and personality features. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Monitoring apparatus for monitoring a user's heart rate and/or heart rate variation

    NARCIS (Netherlands)

    2012-01-01

    A monitoring apparatus (4) monitors a user's heart rate and/or heart rate variation. The apparatus includes a capacitor (22) which is positionable on or near a body part of a person, for example a person's limb, for example an arm (3), such that an electrical capacitance of the capacitor (22) is

  20. A Framework for Evaluating the Software Product Quality of Pregnancy Monitoring Mobile Personal Health Records.

    Science.gov (United States)

    Idri, Ali; Bachiri, Mariam; Fernández-Alemán, José Luis

    2016-03-01

    Stakeholders' needs and expectations are identified by means of software quality requirements, which have an impact on software product quality. In this paper, we present a set of requirements for mobile personal health records (mPHRs) for pregnancy monitoring, which have been extracted from literature and existing mobile apps on the market. We also use the ISO/IEC 25030 standard to suggest the requirements that should be considered during the quality evaluation of these mPHRs. We then go on to design a checklist in which we contrast the mPHRs for pregnancy monitoring requirements with software product quality characteristics and sub-characteristics in order to calculate the impact of these requirements on software product quality, using the ISO/IEC 25010 software product quality standard. The results obtained show that the requirements related to the user's actions and the app's features have the most impact on the external sub-characteristics of the software product quality model. The only sub-characteristic affected by all the requirements is Appropriateness of Functional suitability. The characteristic Operability is affected by 95% of the requirements while the lowest degrees of impact were identified for Compatibility (15%) and Transferability (6%). Lastly, the degrees of the impact of the mPHRs for pregnancy monitoring requirements are discussed in order to provide appropriate recommendations for the developers and stakeholders of mPHRs for pregnancy monitoring.

  1. A Wireless Posture Monitoring System for Personalized Home-Based Rehabilitation

    Directory of Open Access Journals (Sweden)

    Pedro Macedo

    2015-06-01

    Full Text Available We live in an aging society, an issue that will be exacerbated in the coming decades, due to low birth rates and increasing life expectancy. With the decline in physical and cognitive functions with age, it is of the utmost importance to maintain regular physical activity, in order to preserve an individual’s mobility, motor capabilities and coordination. Within this context, this paper describes the development of a wireless sensor network and its application in a human motion capture system based on wearable inertial and magnetic sensors. The goal is to enable, through continuous real- time monitoring, the creation of a personalized home-based rehabilitation system for the elderly population and/or injured people. Within this system, the user can benefit from an assisted mode, in which their movements can be compared to a reference motion model of the same movements, resulting in visual feedback alerts given by the application. This motion model can be created previously, in a ‘learning phase’, under supervision of a caregiver.

  2. A module for psycho-social assessment of personal health monitoring.

    Science.gov (United States)

    Muehlan, Holger; Rhode, Dieter; Schmidt, Silke

    2013-01-01

    This contribution to an interdisciplinary methodology on Personal Health Monitoring (PHM) aims at developing a psycho-social module for health technology assessment on PHM applications. It covers important aspects that should be taken into account for conducting a health technology assessment from a psycho-social perspective. As it could be used in addition to other tools within the PHM-Ethics approach to health technology assessment it is considered as a module of the interdisciplinary methodology. As a prerequisite, we provide a conceptual framework on psycho-social issues of PHM applications. From that framework we delineate an integrated module for psycho-social health technology assessment for PHM applications, consisting of a map highlighting selective psycho-social issues that may appear when applying a PHM system. This psycho-social tool is at least twofold in its intention as a sole HTA tool on the one hand and as an integral part of the interdisciplinary PHM methodology on the other hand. It provides a quick overview on potential benefits and risks from the user's point of view.

  3. Determination of selected metals in the body tissues of occupationally exposed stainless steel workers by neutron activation analysis

    International Nuclear Information System (INIS)

    Kucera, J.; Soukal, L.; Randa, Z.; Borska, L.; Bencko, V.; Tejral, J.

    2002-01-01

    Occupational exposure was examined in a group of 20 workers dealing mainly with welding, polishing, and assembling of stainless steel constructions. Biological monitoring of exposure involved the determination of Cr, Mn, Mo, Ni and V in hair and nails by instrumental neutron activation analysis (INAA), urinary Cr and Mn, serum Cr and blood Mn by neutron activation analysis with radiochemical separation (RNAA). The RNAA procedures employed are briefly described. Significantly elevated levels were found for Cr in hair, nails, serum and urine, Mo in hair, and Mn in blood in the exposed subjects compared to controls. The ratios of the mean elemental concentrations for the exposed/control subjects were as follows: 12.5 for hair Cr, 4.4 for nail Cr, 9.6 for serum Cr, 9.0 for urinary Cr, 1.4 for hair Mo and 1.3 for blood Mn. For quality control purposes a number of biological intercomparison and reference materials were analysed. A good agreement obtained with consensus and/or certified values proved the accuracy of our results. The results for the control group compared also well with reference values, thus indicating that no contamination occurred on sampling and sample treatment prior to irradiation. To be able to evaluate the health effects of exposure, haematological, genotoxicity and immunological parameters were also assayed. A number of immunological parameters were altered in the exposed group compared to controls. However, no significant correlations were found between exposure of the individual workers measured with the aid of personal air particulate samplers and the biological indicators of exposure. A comparison of direct and biological monitoring indicates the complexity of the assessment of health effects of occupational exposure. (author)

  4. An unshielded whole body radioactivity counter for monitoring persons after a radiation accident

    International Nuclear Information System (INIS)

    Katoch, D.S.; Somasundaram, S.

    1979-01-01

    An unshielded chair in which the subject sits, holding a 7.6 cm x 7.6 cm NaI (Tl) detector in his lap, was evaluated for monitoring of persons suspected of internal radioactive contamination following a radiation accident. The reduction in different energy bands of the background gamma-ray spectrum due to self-shielding of the subject was studied for two postures, designated ''upright'' and ''folding'' and the data were analysed in a CDC 3600 computer to obtain the best-fit regression equation relating the reduction factor with body weight and height. The response of the counter was evaluated using an in vitro method and the ranges of under/over-estimation of body burden resulting from assumption of partial/uniform distribution of activity were determined. Counting sensitivities were derived for 13 radioisotopes having gamma-ray energies in the range 145 keV-1.46 MeV. The results are presented and discussed. The study shows that this simple system may be used not only in radiation emergencies but also for operational monitoring of radiation workers for a number of radioisotopes of low and medium radiotoxicity. (auth.)

  5. New web interface for Personal dosimetry VF, a.s

    International Nuclear Information System (INIS)

    Studeny, J.

    2014-01-01

    The lecture will introduce new functions and graphic design WebSOD - web interface Personal dosimetry Service VF. a.s. which will be updated in November 2014. The new interface will have a new graphic design, intuitive control system and will be providing a range of new functions: - Personal doses - display of personal doses from personal, extremity and neutron dosimeters including graphs, annual and electronic listings of doses; - Collective doses - display of group doses for selected periods of time; Reference levels - setting and display of three reference levels; - Evidence - enables administration of monitored individuals - beginning, ending of monitoring, or editing the data of monitored persons and centers. (author)

  6. Determinations of tritium levels in urine and blood samples, medical checkups of persons employed at RC Seibersdorf

    International Nuclear Information System (INIS)

    Irlweck, K.; Teherani, D.K.

    1975-07-01

    Tritium determinations in urine and blood samples were performed with a liquid scintillation counter (Tri Carb No. 3375, PACKARD). In urine samples tritiated water (HTO) was measured after separation of organic substances by adsorption with activated charcoal and following distillation to dryness. In some urine and blood samples total Tritium content was determinated by conbustion in a sample Oxidizer (Mod. 306, PACKARD). Detection limits for HTO and total Tritium measurements were 2,5 pCi/ml and 7 or 15 pCi/ml respectively, taking 2 sigma of statistical error of background values. Tritiumconcentrations in daily urine of occupational exposed persons, employed in RC Seibersdorf occurred up to 8 pCi HTO/ml. An arithmetic mean was 3,85+-2,11 pCi/ml from investigations on 16 persons. Tritiumcontent in urine samples of occupational non exposed persons were about the same level up to 10 pCi HTO/ml. An arithmetic mean was 3,70+-2,65 pCi/ml from measurements on 20 persons. Statistical error of single values was sigma=+-1,85 pCi/ml. There was found no significantly higher concentration in urine of occupational exposed persons compared with a group of non exposed ones. Total Tritium content in urine samples seemed to be somewhat higher than HTO concentrations, also for occupational non exposed persons. Tritium levels in blood were notably higher than have to be expected assuming homogeneous distribution of HTO in body fluids. For occupational exposed persons in RC Seibersdorf Tritium concentrations between 26-58 pCi/ml were found. An estimation about Tritium intake based on such results showed no more than 0,5% of maximum permissible intake for occupational exposed persons in the most unfavorable case. For occupational non exposed persons total Tritium levels in blood were only about 10,7+-5,8 pCi/ml (arithmetic mean of measurements on 15 persons). (author)

  7. Monitoring Calcium in Trout Eggs Exposed to Hydrazine.

    Science.gov (United States)

    1981-07-10

    healthy muscle of the same individual. The notochord of the 8.0 mg/P group showed a higher calcium level than the control group. The chorion did not...calcium in quantities that can be monitored with conventional instru- ments or techniques. The chorion, muscle and notochord tissues were the primary...deposits of calcium pyorantimonate (Figure 26), supported the findings of the microelemental analysis. NOTOCHORD 1. Control The notochord of control embryos

  8. On-line use of personal computers to monitor and evaluate important parameters in the research reactor DHRUVA

    International Nuclear Information System (INIS)

    Sharma, S.K.; Sengupta, S.N.; Darbhe, M.D.; Agarwal, S.K.

    1998-01-01

    The on-line use of Personal Computers in research reactors, with custom made applications for aiding the operators in analysing plant conditions under normal and abnormal situations, has become extremely popular. A system has been developed to monitor and evaluate important parameters for the research reactor DHRUVA, a 100 MW research reactor located at the Bhabha Atomic Research Centre, Trombay. The system was essentially designed for on-line computation of the following parameters: reactor thermal power, reactivity load due to Xenon, core reactivity balance and performance monitoring of shut-down devices. Apart from the on-line applications, the system has also been developed to cater some off-line applications with Local Area Network in the Dhruva complex. The microprocessor based system is designed to function as an independent unit, parallel dumping the acquired data to a PC for application programmes. The user interface on the personal computer is menu driven application software written in 'C' language. The main input parameters required for carrying out the options given in the above menu are: Reactor power, Moderator level, Coolant inlet temperature to the core, Secondary coolant flow rate, temperature rise of secondary coolant across the heat exchangers, heavy water level in the Dump tank and Drop time of individual shut off rods. (author)

  9. Measurement of the external doses at low and high exposures by Agfa personal monitoring film, FD-III-B badge

    International Nuclear Information System (INIS)

    Mihai, F.; Stochioiu, A.; Bercea, S.; Udup, E.; Tudor, I.

    2008-01-01

    Full text: A growing number of papers report occupational exposure monitoring by different dosemeter devices. Researches into improvement of the personal dosemeter systems are encouraged. Dose measurement and especially skin dose measurement, are therefore increasingly important. Methods and acceptable dosemeter are not clearly defined and differ from a dosimetry laboratory to other depending on their specifically work procedure and type of dosemeter utilized. Taking into account the characteristic of the work place (industry, research, medical application) dosemeter have to cover a large dose range. The dose assessment problems are manly in low doses range (under 0.2 mSv) and higher doses range. For example, typical for radiation oncology and nuclear accident dosimetry the dose ranges are on the order of 2-70 Gy and 0.1-5 Gy. This work presents the performance of the Agfa personal monitoring film, badge FD-III-B type used in the most of the occupational exposure monitoring from Romania. The FD-III-B dosimeter, manufactured in Romania, is used for monitoring personnel working in radioactive environment - the photodosimetric method is the one of the most reliable method presenting the advantage that the film may be considered as master probe over 30 year and may be utilized during litigation. The dosimeter contains metallic filters of Al, Cu, Pb with different thicknesses, a plastic filter and a open window. The badge FD-III-B is a class B dosimeter according to the dose range and an indices 3 dosimeter from energy range of the radiations in conformity with Romanian Standard in force. Film Agfa 'personal monitoring', tacked in this experiment, consists of a low speed film (D2) and a very sensitive film (D10) designed for recording X-ray, gamma and beta radiation over the doses range 0.1 mSv to 1 Sv. The experiments have been effectuated at different background optical density (base fog) of the films and at different sources of radiation: 13 :7Cs, 60 Co and 24 : 1 Am

  10. Flexible Conductive Composite Integrated with Personal Earphone for Wireless, Real-Time Monitoring of Electrophysiological Signs.

    Science.gov (United States)

    Lee, Joong Hoon; Hwang, Ji-Young; Zhu, Jia; Hwang, Ha Ryeon; Lee, Seung Min; Cheng, Huanyu; Lee, Sang-Hoon; Hwang, Suk-Won

    2018-06-14

    We introduce optimized elastomeric conductive electrodes using a mixture of silver nanowires (AgNWs) with carbon nanotubes/polydimethylsiloxane (CNTs/PDMS), to build a portable earphone type of wearable system that is designed to enable recording electrophysiological activities as well as listening to music at the same time. A custom-built, plastic frame integrated with soft, deformable fabric-based memory foam of earmuffs facilitates essential electronic components, such as conductive elastomers, metal strips, signal transducers and a speaker. Such platform incorporates with accessory cables to attain wireless, real-time monitoring of electrical potentials whose information can be displayed on a cell phone during outdoor activities and music appreciation. Careful evaluations on experimental results reveal that the performance of fabricated dry electrodes are comparable to that of commercial wet electrodes, and position-dependent signal behaviors provide a route toward accomplishing maximized signal quality. This research offers a facile approach for a wearable healthcare monitor via integration of soft electronic constituents with personal belongings.

  11. Ethically sound technology? Guidelines for interactive ethical assessment of personal health monitoring.

    Science.gov (United States)

    Palm, Elin; Nordgren, Anders; Verweij, Marcel; Collste, Göran

    2013-01-01

    Novel care-technologies possess a transformational potential. Future care and support may be provided via monitoring technologies such as smart devices, sensors, actors (robots) and Information and Communication Technologies. Such technologies enable care provision outside traditional care institutions, for instance in the homes of patients. Health monitoring may become "personalized" i.e. tailored to the needs of individual care recipients' but may also alter relations between care providers and care recipents, shape and form the care environment and influence values central to health-care. Starting out from a social constructivist theory of technology, an interactive ethical assessment-model is offered. The suggested model supplements a traditional analysis based on normative ethical theory (top-down approach) with interviews including relevant stakeholders (a bottom-up approach). This method has been piloted by small-scale interviews encircling stakeholder perspectives on three emerging technologies: (1) Careousel, a smart medicine-management device, (2) Robot Giraff, an interactive and mobile communication-device and (3) I-Care, a care-software that combines alarm and register system. By incorporating stakeholder perspectives into the analysis, the interactive ethical assessment model provides a richer understanding of the impact of PHM-technologies on ethical values than a traditional top-down model. If the assessment is conducted before the technology has reached the market - preferably in close interaction with developers and users - ethically sound technologies may be obtained.

  12. Study of the exposures received by the persons involved in the transportation of radioactive materials

    International Nuclear Information System (INIS)

    Hamard, J.; Sousselier, Y.

    1983-01-01

    An important step in the optimization process applied to exposures in the field of the transport of radioactive materials is an accurate inventory of the exposures actually received by the workers. The results of this study underlines that nearly all the doses received are well below the threshold values for the classification of the workers as occasionally exposed and a fortiori as professionally exposed and consequently no personal monitoring should be necessary for them. Thus the inventory of exposures is somewhat difficult as the workers implied in the transport process are not classified as exposed workers and not subject to personnal or collective dosimetry. Therefore a good knowledge of the exposures received during the transport of irradiated fuels should require a systematic follow up of this kind of transport all along their route including a careful dosimetric monitoring of the workers taking part in the transport. On the other hand, the reduction of the doses obtained by increasing the mechanization involves very high monetary costs as compared to the reduction of the detriment. Perhaps a more important reduction of the exposures could be attained by a better protection in the cars or lorries used for the transport of categories A and B packages. But it seems that in the case of the transports, the optimization is applied mainly during the conception and the testing of the packages and only little progress will be possible without involving disproportionated monetary costs. 4 references, 10 tables

  13. Bio-monitoring for the genotoxic assessment in road construction workers as determined by the buccal micronucleus cytome assay.

    Science.gov (United States)

    Çelik, Ayla; Yildirim, Seda; Ekinci, Seda Yaprak; Taşdelen, Bahar

    2013-06-01

    Buccal micronucleus cytome (BMCyt) assay monitors genetic damage, cell proliferation and cell death in humans exposed to occupational and environmental agents. BMCyt is used as an indicator of genotoxic exposure, since it is associated with chromosomal instability. There is little research on the occupational exposure among road construction workers for genotoxicity testing. In the present study, we evaluated MN frequencies and other nuclear changes, karyorrhexis (KR), karyolysis (KL), broken egg (BE), binucleate (BN), condensed chromatin cell (CCC), and picnotic cell (PC) in buccal mucosa cells of 40 road construction workers (twenty smokers and twenty non-smokers) and 40 control groups consisting of healthy persons (twenty smokers and twenty non-smokers). Microscopic observation was performed of 2000 cells per individual in both road construction workers and control group. In control and worker groups, for each person repair index (RI) was calculated via formula KR+L/BE+MN. The results showed a statistically significant increase in the frequency of MN in buccal epithelial cells of exposed group compared with control group (proad construction workers, RI is lower than the control group. There is a significant difference between workers and control group (proad paving operations are absorbed by workers and that asphalt fume exposure is able to significantly induce cytogenetic damage in buccal mucosa cells of workers after controlling some possible confounding factors, such as age, sex and smoking habits. In addition to determination of nuclear changes and the micronucleus, the determination of RI value presents a new approach to genotoxic bio-monitoring assessment studies of occupationally exposed population. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Antenatal Exposure of Persons from Belarus Following the Chernobyl Accidents: Neuropsychiatric Aspects

    International Nuclear Information System (INIS)

    Igumnov, S.; Drozdovitch, V.

    2004-01-01

    Ten years follow-up investigation of intellectual development of 250 persons from Belarus exposed in utero following the Chernobyl accident has been conducted. Exposed cohort was compared with a control group of 250 persons in the same age from non and slightly contaminated regions. For each study subject, individual antenatal doses were reconstructed for the following pathways of exposure: (1) internal doses to thyroid gland arising from the intake of ''131 I via inhalation or ingestion; and (2) external doses from radionuclides deposited on the ground. Neuropsychiatry and psychological examinations were performed among persons of both groups at the age 6-7 years, 10-12 years, and 15-16 years. At the age of 6-7 years the persons in the exposed group had a mean full-scale intelligent quotient (IQ) lower than the control group. At the age of 10-12 and 15-16 years there were no statistically significant differences between the two groups. Positive dynamics of intellectual development in persons of both groups has been observed up to age of 15-16 years. No statiscally significant correlation was found in exposed group between individual thyroid dose as well as individual antenatal external dose and IQ at the different ages. In both groups we notice a positive moderate correlation between IQ of persons and the educational level of their parents. We conclude that probably a significant role in the genesis of borderline intellectual functioning and emotional disorders in the exposed group of persons was played by unfavorable factors such as a low educational level of parents, the break of micro social contacts and adaptation difficulties, which appear following the evacuation and relocation from the contaminated areas. (Author) 10 refs-

  15. Working level measurement of radon daughters and thoron daughters by personal dosimetry and continuous monitoring

    International Nuclear Information System (INIS)

    Phillips, C.R.; Leung, H.

    1981-01-01

    The performance of personal alpha dosimeters in mixed radon daughter and thoron daughter atmospheres in Ontario uranium mines is described together with monitoring developments which enable the radon daughter working level to be determined separately. The theoretical bases for continuous and integrated working level measurements based on individual and gross counts are presented in terms of the weighting factor for combining the thoron daughter working level with the radon daughter working level, and in terms of the in-growth time of the air. Implications for the determination of working level in the presence of thoron daughters are discussed

  16. Exposed persons at the Chernobyl Atomic Power Station accident: acute radiation effects

    International Nuclear Information System (INIS)

    Gus'kova, A.K.; Baranov, A.E.; Barabanova, A.V.

    1987-01-01

    Observation made over 115 patients with acute radiation sickness due to exposure external γ- and β-rays confirmed high efficiency of the earlier proposed principles of prognostication of the degree of severity by clinical manifestations of the primary disease response and those of separate syndromes, using the methods of hematological and cytogenetic analyses. Out of 115 victims, 56 persons had radiation burns (RB), 17 intestinal syndrome (IS), 80 - oropharengeal syndrome (ORS), 7 - interstitial radiation pneumonitis (IRP). In thanatogenesis, of prime importance were: RB (more than 40% of the body surface) - 19 persons and IRP - 7 persons. A severe course of intestinal and oropharengeal syndromes was combined with other fatal manifestations of radiation injury. Early isolation of patients (2-4 stages), selective decontamination of the intestine, prescription of a wide spectrum antibiotics, antimycotic and antiviral drugs, as well as γ-globulin could practically remove the risk of the development of fatal infectious complications during a medullary andtransitory forms of radiation sickness

  17. Miniaturized inertial impactor for personal airborne particulate monitoring: Numerical model

    Science.gov (United States)

    Cortelezzi, Luca; Pasini, Silvia; Bianchi, Elena; Dubini, Gabriele

    2017-11-01

    The rising level of fine particle matter's (PM10, PM2.5 and PM1) pollution in the world has increased the interest in developing portable personal air-qualitity monitoring systems. To answer this need, we conceived a miniaturized inertial impactor. The development of such an impactor becomes more challenging as the diameter of the particles to be collected becomes smaller, since the velocities required to induce the impact of finer particulate matter become higher. To overcome these challenges, we modeled numerically the fluid dynamics and particles transport within the impactor. Our simulations show that the fluid flow within the impactor becomes unstable as the Reynolds number is increased to capture finer particles. Furthermore, the onset of these instabilities depends not only on the Reynolds number but also on the geometry of the impactor. The unsteady flow within the impactor influences the trajectories of the particles to be collected, especially the smaller particles. The particles trajectories shows that the impaction location varies substantially as the Reynolds number increases and, consequently, the efficiency of the impactor deteriorates. Finally, we optimize the design of our impactor to maximize its collection efficiency. CARIPLO Fundation - project MINUTE (Grant No. 2011-2118).

  18. Micronuclei frequency in children exposed to environmental mutagens: a review

    DEFF Research Database (Denmark)

    Neri, Monica; Fucic, Aleksandra; Knudsen, Lisbeth E

    2003-01-01

    Cytogenetic monitoring has been traditionally used for the surveillance of populations exposed to genotoxic agents. In recent years sensitivity problems emerged in surveys of populations exposed to low levels of mutagens, and therefore alternative approaches have been explored. Biomonitoring....... The limited number of published papers indicates that the conduct of properly designed studies on the effect of environmental pollutants in children may be difficult. This review confirmed the usefulness of MN assay in biomonitoring studies conducted in children, revealing that in many circumstances...

  19. Biomarkers of oxidative stress in electroplating workers exposed to hexavalent chromium.

    Science.gov (United States)

    Pan, Chih-Hong; Jeng, Hueiwang Anna; Lai, Ching-Huang

    2018-01-01

    This study evaluates levels of biomarkers of oxidative DNA damage and lipid peroxidation in 105 male workers at 16 electroplating companies who had been exposed to hexavalent chromium (Cr(VI)). The study participants were 230 non-smoking male workers, comprising 105 electroplating workers who had been exposed to chromium and 125 control subjects who performed office tasks. Personal air samples, spot urine samples, hair samples, fingernail samples and questionnaires were used to quantify exposure to Cr(VI), oxidative DNA damage, lipid peroxidation, and environmental pollutants. Both the geometric mean personal concentrations of Cr(VI) of the Cr-exposed workers and the total Cr concentrations in the air to which they were exposed significantly exceeded those for the control subjects. The geometric mean concentrations of Cr in urine, hair and fingernails, and the urinary 8-hydroxy-2'-deoxyguanosine (8-OHdG), and malondialdehyde (MDA) levels in the Cr(VI) exposed workers exceeded those in the control subjects. Daily cumulative Cr(VI) exposure and urinary Cr were significantly correlated with urinary 8-OHdG levels following adjustments for covariates. A ten-fold increase in urinary Cr level was associated with a 1.73-fold increase in urinary 8-OHdG level. Daily cumulative Cr(VI) exposure and urinary Cr level were significantly correlated with urinary MDA level following adjustments for covariates. A ten-fold increase in urinary Cr was associated with a 1.45-fold increase in urinary MDA. Exposure to Cr(VI) increased oxidative DNA injury and the oxidative deterioration of lipids in electroplating workers.

  20. Generalized concept for the estimation of body dose for radiation workers exposed to external #betta#-rays

    International Nuclear Information System (INIS)

    Piesch, E.; Boehm, J.; Heinzelmann, M.

    1983-01-01

    In radiation protection monitoring the need exists for an estimation of body dose due to external #betta#-rays, for instance if the #betta#-dose rate at the working area is expected to be high according to the data of source activity or room contamination, the indicated dose values of a personal dosemeter exceed the operational limit for the organ or tissue depth of interest, or a person was exposed to a significant dose. On behalf of the Federal Ministry of the Interior, Federal Republic of Germany, a guideline is now under preparation which offers a standardized concept of the estimation of #betta#-doses in personnel monitoring. The calculation models discussed here will be used as a basis for any case of external #betta#-irradiation where, in connection with the German Radiation Protection Ordinance, the ICRP dose equivalent limits are reached or the dosemeter readings are not representative for an individual exposure. The generalized concept discussed in the paper relates to: the calculation of #betta#-dose on the basis of source activity or spectral particle fluence and takes into account the special cases of point sources, area sources and volume sources; the estimation of body dose on the basis of calculated data or measured results from area or personnel monitoring, taking into account the dose equivalent in different depths of tissue, in particular the dose equivalent to the skin, the lens of the eye and other organs; and finally the estimation of skin dose due to the contamination of the skin surface. Basic reference data are presented in order to estimate the dose equivalent of interest which varies significantly in the #betta#-radiation field as a function of the maximum #betta#-energy, distance to the source, size of the source, activity per area for surface contamination and activity per volume for air contamination

  1. The preventive approach: OPCAT and the prevention of violence and abuse of persons with mental disabilities by monitoring places of detention.

    Science.gov (United States)

    Sveaass, Nora; Madrigal-Borloz, Victor

    Adopted in December 2002, the United Nations Optional Protocol to the Convention against Torture and other Cruel, Inhuman or Degrading Treatment or Punishment establishes a system of regular visits undertaken by independent international and national bodies to places where people are deprived of their liberty, in order to prevent torture and other cruel, inhuman or degrading treatment or punishment. The article explores how this collaboration between national and international bodies, with independent mandates to carry out such unannounced visits, represents an important effort in the process of protecting persons with mental disabilities who are detained and who are particularly exposed to exploitation and other forms of serious human rights violations, contrary to Article 16 of the Convention on the Rights of Persons with Disabilities. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Occupational radiation exposure monitoring among radiation workers in Nepal

    International Nuclear Information System (INIS)

    Bhatt, Chhavi Raj; Shrestha, Shanta Lall; Khanal, Tara; Ween, Borgny

    2008-01-01

    Nepal was accepted as a member of the IAEA in 2007. Nepal is one of the world's least developed countries and is defined in Health Level IV. The population counted 26.4 millions in 2007. The health care sector increases with new hospitals and clinics, however, Nepal has no radiation protection authority or radiation protection regulation in the country until now. The radiation producing equipment in the health sector includes conventional X-ray and dental X-ray equipment, fluoroscopes, mammography, CT, catheterization laboratory equipment, nuclear medicine facilities, a few linear accelerators, Co 60 teletherapy and High Dose Rate brachytherapy sources. The situation regarding dosimetry service for radiation workers is unclear. A survey has been carried out to give an overview of the situation. The data collection of the survey was performed by phone call interviews with responsible staff at the different hospitals and clinics. Data about different occupationally exposed staff, use of personal radiation monitoring and type of dosimetry system were collected. In addition, it was asked if dosimetry reports were compiled in files or databases for further follow-up of staff, if needed. The survey shows that less of 25% of the procedures performed on the surveyed hospitals and clinics are performed by staff with personnel radiation monitoring. Radiation monitoring service for exposed staff is not compulsory or standardized, since there is no radiation protection authority. Nepal has taken a step forward regarding radiation protection, with the IAEA membership, although there are still major problems that have to be solved. An evaluation of the existing practice of staff dosimetry can be the first helpful step for further work in building a national radiation protection authority. (author)

  3. Reliability of Sleep Measures from Four Personal Health Monitoring Devices Compared to Research-Based Actigraphy and Polysomnography

    Directory of Open Access Journals (Sweden)

    Janna Mantua

    2016-05-01

    Full Text Available Polysomnography (PSG is the “gold standard” for monitoring sleep. Alternatives to PSG are of interest for clinical, research, and personal use. Wrist-worn actigraph devices have been utilized in research settings for measures of sleep for over two decades. Whether sleep measures from commercially available devices are similarly valid is unknown. We sought to determine the validity of five wearable devices: Basis Health Tracker, Misfit Shine, Fitbit Flex, Withings Pulse O2, and a research-based actigraph, Actiwatch Spectrum. We used Wilcoxon Signed Rank tests to assess differences between devices relative to PSG and correlational analysis to assess the strength of the relationship. Data loss was greatest for Fitbit and Misfit. For all devices, we found no difference and strong correlation of total sleep time with PSG. Sleep efficiency differed from PSG for Withings, Misfit, Fitbit, and Basis, while Actiwatch mean values did not differ from that of PSG. Only mean values of sleep efficiency (time asleep/time in bed from Actiwatch correlated with PSG, yet this correlation was weak. Light sleep time differed from PSG (nREM1 + nREM2 for all devices. Measures of Deep sleep time did not differ from PSG (SWS + REM for Basis. These results reveal the current strengths and limitations in sleep estimates produced by personal health monitoring devices and point to a need for future development.

  4. Dosimetric monitoring in Ukraine - present status and path to the future

    International Nuclear Information System (INIS)

    Chumak, V.; Boguslavskaya, A.

    2005-01-01

    Full text: Ukraine is the country which utilizes radiation in many peaceful areas. So, nuclear energy sector includes 15 power units (including two new units commissioned in 2004), nuclear fuel cycle also include uranium mines, radiation sources are widely used in industry, science and medicine. As a result, about 50,000 occupationally exposed workers require dosimetric monitoring. However, presently dosimetry services in Ukraine cover only about 38,000 occupationally exposed workers, including 9,100 medical professionals, 16,400 employees of 5 nuclear power plants and ca. 12,400 workers dealing with other sources of occupational exposure (industry, research). Territorial dosimetry services, responsible for dosimetric monitoring in industry and medicine operate in 13 of 25 oblasts (regions) of Ukraine. The coverage of critical groups by dosimetric monitoring is variable and ranges from 38 % to 100 % depending on the oblast. With rare exception, instrumentation is represented by outdated manual TLD systems (inaccurate and insufficiently sensitive) capable of measurement of deep photon dose only; no personal monitoring of beta and neutron exposure is possible now. Quality assurance is limited to the annual metrological attestation of the dosimetric instruments. No information exchange infrastructure and dosimetric registry are in place. The dosimetric data is stored in home-made data environments or even in paper log-books, no data on individual doses is conveyed to central depository, which could be easily accessible for regulating authorities. Although the standing law requires elaboration of the United System for monitoring and registration individual doses, little was done so far, mainly due to lack of domestic funding. However, intention is strong to build such network in accordance with the best practice, covering not only the aspects of physical measurement and data storage, but also quality assurance, accreditation programs and training of the local personnel

  5. Personality correlates of the Five-Factor Model for a sample of business owners/managers: associations with scores on Self-Monitoring, Type A Behavior, Locus of Control, and Subjective Well-being.

    Science.gov (United States)

    Morrison, K A

    1997-02-01

    Bivariate relationships were examined between scores on the Five-Factor Model of personality and four personality dimensions including Self-monitoring, Locus of Control, Type A Behavior, and Subjective Well-being. Data were collected from 307 franchise business owner/managers from four different industries. Scores for Self-monitoring were positively related to those on Extraversion; Self-monitoring was the only personality measure significantly correlated with scores on Openness to Experience. Scores for Type A Behavior, measured by the Jenkins Activity Survey, were negatively correlated with Agreeableness and positively correlated with those for Extraversion. Somewhat surprisingly, the score for Type A Behavior had a relatively low correlation with the score for Conscientiousness. Scores for Subjective Well-being and Locus of Control were most strongly correlated with the positive pole of Neuroticism (Emotional Stability), Conscientiousness, and Extraversion. Possible explanations for the observed relationships are discussed.

  6. [THE ORGANIZATIONAL TECHNOLOGIES OF INCREASING OF EFFECTIVENESS OF DISPENSARY MONITORING OF HIV-INFECTED PERSONS].

    Science.gov (United States)

    Moskvitcheva, M G; Yu, Kitmanova L

    2015-01-01

    The organizational technologies of increasing effectiveness ofdispensarization monitoring of HIV-infected persons are to targeted to development in patients commitment to get medical care. The cohort monitoring of registered patients receiving anti-retrovirus therapy permitted to evaluate effectiveness of organizational model of multi-professional team developing commitment ofpatients to anti-retrovirus therapy in conditions of center ofprevention and struggle with AIDS and infectious diseases. The criteria ofeffectiveness offunctioning ofmulti-professional team are developed and implemented The list of criteria include percentage of patients in cohort with optimal commitment (not lower than 95% of applied dosage of anti-retrovirus pharmaceuticals at 12th, 24th, 36th, 48th and 60th month), percentage ofpatients with achieved effect of anti-retrovirus therapy, percentage of patients proceeding anti-retrovirus therapy. The multi-professional team implemented motivational techniques of behavior alteration and patient-oriented care. The main strategy of development of of commitment to anti-retrovirus therapy under HIV-infection is determined as management of resources and risks capable decreasing commitment to dispensarization monitoring. The analysis of problems permitted to structure them in risks of commitment failure: medical (13.7%), medical biological under using psychoactive substances (43.1%), psychological (27.7%), social (15.5%). This listing determined the profile of specialists of multi-professional team. The ranking of risks lead out to the first ranking place medical risks, including diagnosed tuberculosis, combination of secondary and concomitant diseases inpatient, number of intaking pills more than 7 per day. The second ranking place took medical biological risks in users of psychoactive substances. Up to 60th month the anti-retrovirus therapy was proceeded by 61.5% of users of psychoactive substances with optimal commitment in 60%. The implementation

  7. USING PROTEOMICS TO MONITOR PROTEIN EXPRESSION IN HUMAN CELLS EXPOSED TO CARCINOGENS

    Science.gov (United States)

    People are continuously exposed exogenously to varying amounts of chemicals that have been shown to have carcinogenic properties in experimental systems. It has been estimated that exposure to environmental chemical carcinogens in the environment may contribute significantly to t...

  8. Thyroid neoplasia in Marshall Islanders exposed to nuclear fallout

    International Nuclear Information System (INIS)

    Hamilton, T.E.; van Belle, G.; LoGerfo, J.P.

    1987-01-01

    We studied the risk of thyroid neoplasia in Marshall Islanders exposed to radioiodines in nuclear fallout from the 1954 BRAVO thermonuclear test. We screened 7266 Marshall Islanders for thyroid nodules; the islanders were from 14 atolls, including several southern atolls, which were the source of the best available unexposed comparison group. Using a retrospective cohort design, we determined the prevalence of thyroid nodularity in a subgroup of 2273 persons who were alive in 1954 and who therefore were potentially exposed to fallout from the BRAVO test. For those 12 atolls previously thought to be unexposed to fallout, the prevalence of thyroid nodules ranged from 0.9% to 10.6%. Using the distance of each atoll from the test site as a proxy for the radiation dose to the thyroid gland, a weighted linear regression showed an inverse linear relationship between distance and the age-adjusted prevalence of thyroid nodules. Distance was the strongest single predictor in logistic regression analysis. A new absolute risk estimate was calculated to be 1100 excess cases/Gy/y/1 X 10(6) persons (11.0 excess cases/rad/y/1 million persons), 33% higher than previous estimates. We conclude that an excess of thyroid nodules was not limited only to the two northern atolls but extended throughout the northern atolls; this suggests a linear dose-response relationship

  9. Geophysical data collection using an interactive personal computer system. Part 1. ; Experimental monitoring of Suwanosejima volcano

    Energy Technology Data Exchange (ETDEWEB)

    Iguchi, M. (Kyoto Univerdity, Kyoto (Japan). Disaster Prevention Reserach Institute)

    1991-10-15

    In the article, a computer-communication system was developed in order to collect geophysical data from remote volcanos via a public telephpne network. This system is composed of a host presonal computer at an observatory and several personal computers as terminals at remote stations. Each terminal acquires geophysical data, such as seismic, intrasonic, and ground deformation date. These gara are stored in the terminals temporarily, and transmitted to the host computer upon command from host computer. Experimental monitoring was conducted between Sakurajima Volcanological Observatory and several statins in the Satsunan Islands and southern Kyushu. The seismic and eruptive activities of Suwanosejima volcano were monitored by this system. Consequently, earthquakes and air-shocks accompanied by the explosive activity were observed. B-type earthquakes occurred prio to the relatively prolonged eruptive activity. Intermittent occurrences of volcanic tremors were also clearly recognized from the change in mean amplitubes of seismic waves. 7 refs., 10 figs., 2 tabs.

  10. Self-Monitoring in Middle Childhood: Personality and Social Correlates.

    Science.gov (United States)

    Musser, Lynn M.; Browne, Beverly A.

    1991-01-01

    Measures of self-monitoring and other measures were completed by 93 elementary school children on 3 occasions during a 15-month period. Self-monitoring was related to peer acceptance and self-esteem, but the relation may have been influenced by gender. Boys' self-monitoring correlated with popularity measures, whereas girls' did not. (BC)

  11. Revisiting the Malleable Self: Brand Effects on Consumer Self-Perceptions of Personality Traits

    NARCIS (Netherlands)

    Fennis, B.M.; Pruyn, Adriaan T.H.; Maasland, Mascha

    2005-01-01

    Four experiments examined the relationships between dimensions of brand personality and consumer self-perceptions of personality traits. We hypothesized and found that when consumers are exposed to brands, brand personality dimensions may affect individual assessments of personality traits. Study 1

  12. Individual monitoring of medical staff working in interventional radiology in Switzerland using double dosimetry

    International Nuclear Information System (INIS)

    Damet, J.; Bailat, C.; Bize, P.; Buchillier, Th.; Tosic, M.; Verdun, F.R.; Baechler, S.

    2011-01-01

    Physicians who frequently perform fluoroscopic examinations are exposed to high intensity radiation fields. The exposure monitoring is performed with a regular personal dosimeter under the apron in order to estimate the effective dose. However, large parts of the body are not protected by the apron (e.g. arms, head). Therefore, it is recommended to wear a supplemental dosimeter over the apron to obtain a better representative estimate of the effective dose. The over-apron dosimeter can also be used to estimate the eye lens dose. The goal of this study was to investigate the relevance of double dosimetry in interventional radiology. First the calibration procedure of the dosimeters placed over the apron was tested. Then, results of double dosimetry during the last five years were analyzed. We found that the personal dose equivalent measured over a lead apron was underestimated by ∼20% to ∼40% for X-ray beam qualities used in radiology. Measurements made over five-year period confirm that the use of a single under-apron dosimeter is inadequate for personnel monitoring. Relatively high skin dose (>10 mSv/month) would have remained undetected without a second dosimeter placed on the apron.

  13. A quality assurance system for personal monitoring in Ireland: experience to date and transition from EN 45001 to ISO/IEC 17025

    International Nuclear Information System (INIS)

    Currivan, L.; Spain, D.; Rafferty, B.

    2002-01-01

    Up to 2000 the RPII was the competent authority for approval of dosimetry services operating within Ireland. However the transposition into Irish Law of Council Directive 96/29 Euratom in May 2000 means that dosimetry services operating in Ireland must now attain accreditation to the standard of EN-45001 or its equivalent. To comply with this new legislation the RPII sought accreditation for the Dosimetry Service from the Irish National Accreditation Board (NAB). In accordance with the EN-45000 series of European Standards and the relevant ISO guides NAB tests accuracy of results and accredits organisations as appropriate. In September 2000 accreditation was granted to the Dosimetry Service for individual monitoring of personnel who are occupationally exposed to ionising radiation. The scope of the accreditation covers the evaluation of personal doses, for photon and beta, using TLD. Frequent internal quality audits, together with periodic inter-laboratory test programmes, ensure that these quality standards are maintained. This accreditation fulfils the approval under legislation for dosimetry services. The new standard, ISO/IEC 17025, was introduced by ISO (the International Organization for Standardization) and IEC (the International Electrotechnical Commission) in 1999. This standard was introduced in Ireland by NAB and will be implemented for future assessments. The aim of this paper is to describe the quality system currently operated by the RPII's Dosimetry Service, our practical experience to date, and to outline the transition from EN-45001 to ISO/IEC 17025

  14. Out-of-home placement to age 18 years in children exposed to a postpartum mental disorder.

    Science.gov (United States)

    Vigod, Simone N; Laursen, Thomas Munk; Ranning, Anne; Nordentoft, Merete; Munk-Olsen, Trine

    2018-04-17

    Little is known about risk of custody loss or out-of-home placement among children whose mothers experience postpartum mental disorders, and whether this risk differs from that of children whose mothers had earlier onset of their mental disorder. National Danish registers comprising 1 868 467 births (1982-2012) were used to determine how the timing of maternal illness onset influences out-of-home placement risk up to age 18 years among children exposed to a maternal mental disorder. Compared to children unexposed to maternal mental illness, risk was higher for children exposed to a maternal mental disorder whose mothers had a first contact for a mental disorder in the 0-12 months of predelivery (8.17/1000 person-years; aIRR 4.56, 95% CI 4.08-5.09), the first 3 months postpartum (4.60/1000 person-years; 3.55, 2.95-4.26) and 4-12 months postpartum (6.49/1000 person-years; 3.93, 3.50-4.41). Risk was even higher for children exposed to a maternal mental disorder when illness onset was more than 1-year predelivery (9.11/1000 person-years; 5.48, 5.32-5.66). Risk of out-home placement in children exposed to mothers with a new-onset postpartum mental disorder is almost as high as in children whose mothers have long-standing illness. A better understanding of the trajectories of these mothers and children is warranted. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Personality in cyberspace: personal Web sites as media for personality expressions and impressions.

    Science.gov (United States)

    Marcus, Bernd; Machilek, Franz; Schütz, Astrid

    2006-06-01

    This research examined the personality of owners of personal Web sites based on self-reports, visitors' ratings, and the content of the Web sites. The authors compared a large sample of Web site owners with population-wide samples on the Big Five dimensions of personality. Controlling for demographic differences, the average Web site owner reported being slightly less extraverted and more open to experience. Compared with various other samples, Web site owners did not generally differ on narcissism, self-monitoring, or self-esteem, but gender differences on these traits were often smaller in Web site owners. Self-other agreement was highest with Openness to Experience, but valid judgments of all Big Five dimensions were derived from Web sites providing rich information. Visitors made use of quantifiable features of the Web site to infer personality, and the cues they utilized partly corresponded to self-reported traits. Copyright 2006 APA, all rights reserved.

  16. Development and Performance Characteristics of Personal Gamma Spectrometer for Radiation Monitoring Applications

    Directory of Open Access Journals (Sweden)

    Hye Min Park

    2016-06-01

    Full Text Available In this study, a personal gamma (γ spectrometer was developed for use in applications in various fields, such as homeland security and environmental radiation monitoring systems. The prototype consisted of a 3 × 3 × 20 mm3 Ce-doped Gd–Al–Ga–garnet (Ce:GAGG crystal that was coupled to a Si photomultiplier (SiPM to measure γ radiation. The γ spectrometer could be accessed remotely via a mobile device. At room temperature, the implemented Ce:GAGG-SiPM spectrometer achieved energy resolutions of 13.5%, 6.9%, 5.8%, and 2.3% for 133Ba at 0.356 MeV, 22Na at 0.511 MeV, 137Cs at 0.662 MeV, and 60Co at 1.33 MeV, respectively. It consumed only about 2.7 W of power, had a mass of just 340 g (including the battery, and measured only 5.0 × 7.0 cm2.

  17. Management of Patients with Post- Traumatic Exposed Bones at Moi ...

    African Journals Online (AJOL)

    Background: The global frequency for open long bone fracture is at least 11.5 cases per 100,000 persons per year. Precise published research information regarding the characteristics and the management of patients with post- traumatic exposed bones for Africa, Kenya and Moi Teaching and Referral Hospital- Eldoret is ...

  18. The need for control, safety and trust in healthcare: A qualitative study among adolescents and young adults exposed to family violence.

    Science.gov (United States)

    van Rosmalen-Nooijens, Karin A W L; Lo Fo Wong, Sylvie H; Prins, Judith B; Lagro-Janssen, Antoine L M

    2017-06-01

    Adolescents and young adults (AYA) exposed to family violence are in need of professional healthcare. However, only one-third of them seek professional help. This study investigates healthcare needs of twelve AYA exposed to family violence. Semi-structured face-to-face interviews using purposive sampling to reach diversity. Open thematic coding was used to identify the most important themes. Participants experienced emotional problems, distrusted others and felt unsafe as an important consequence of their exposure to family violence. All participants expressed a need for help, but as help involved informing others, they considered it unsafe. Trust, safety and control regarding healthcare interventions emerged as vital needs. The anonymity of the Internet was considered as offering safeguards in seeking and receiving help. Trust, safety and control regarding healthcare interventions emerged as vital needs for AYA exposed to family violence. The great importance of being in control of healthcare interventions has not been reported earlier. A personal bond can lower the need for control. To comply with the three basic needs, healthcare providers should grant AYA as much control as possible while still monitoring patient safety. The Internet can be an important resource for offering low-threshold professional and peer support. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Occupational radiation exposure in Germany in 2011. Report of the radiation protection register

    International Nuclear Information System (INIS)

    Frasch, Gerhard; Kammerer, Lothar; Karofsky, Ralf; Mordek, Else; Schlosser, Andrea; Spiesl, Josef

    2013-04-01

    In Germany, persons who are occupationally exposed to ionising radiation are monitored by several official dosimetry services that transmit the dose records about individual radiation monitoring to the Radiation Protection Register of the Federal Office for Radiation Protection (BfS). The purpose of the Radiation Protection Register is to supervise the keeping of the dose limits and to monitor the compliance with the radiation protection principle ''Optimisation'' by performing detailed annual statistical analyses of the monitored persons and their radiation exposure. The annual report of the Radiation Protection Register provides information about status and development of occupational radiation exposure in Germany. In 2011, about 350,000 workers were monitored with dosemeters for occupational radiation exposure. The number increased during the past five years continuously by 10 %. Only 19 % of the monitored persons received measurable personal doses. The average annual dose of these exposed workers was 0.58 mSv corresponding to 3 % of the annual dose limit of 20 mSv for radiation workers. In total, 7 persons exceeded the annual dose limit of 20 mSv, i.e. two cases per 100,000 monitored persons. The collective dose of the monitored persons decreased to 38.5 Person-Sv, the lowest value since the last fifty years of occupational dose monitoring. In 2010, 45 airlines calculated the route doses of 39,000 members of the aircraft crew personnel by using certified computer programmes for dose calculation and sent the accumulated monthly doses via the Federal Office for Civil Aviation (''Luftfahrt-Bundesamt, LBA'') to the BfS. The collective dose of the aircraft crew personnel is 83 person-Sv, and thus significantly higher than the total collective dose of the workers monitored with personal dosemeters (38.5 person-Sv). The annual average dose of aircraft crew personnel was 2.12 mSv and decreased compared to 2010 (2,30 mSv). In 2011, about 70,000 outside-workers were in

  20. Occupational radiation exposure in Germany in 2011. Report of the radiation protection register; Die berufliche Strahlenexposition in Deutschland 2011. Bericht des Strahlenschutzregisters

    Energy Technology Data Exchange (ETDEWEB)

    Frasch, Gerhard; Kammerer, Lothar; Karofsky, Ralf; Mordek, Else; Schlosser, Andrea; Spiesl, Josef

    2013-04-15

    In Germany, persons who are occupationally exposed to ionising radiation are monitored by several official dosimetry services that transmit the dose records about individual radiation monitoring to the Radiation Protection Register of the Federal Office for Radiation Protection (BfS). The purpose of the Radiation Protection Register is to supervise the keeping of the dose limits and to monitor the compliance with the radiation protection principle ''Optimisation'' by performing detailed annual statistical analyses of the monitored persons and their radiation exposure. The annual report of the Radiation Protection Register provides information about status and development of occupational radiation exposure in Germany. In 2011, about 350,000 workers were monitored with dosemeters for occupational radiation exposure. The number increased during the past five years continuously by 10 %. Only 19 % of the monitored persons received measurable personal doses. The average annual dose of these exposed workers was 0.58 mSv corresponding to 3 % of the annual dose limit of 20 mSv for radiation workers. In total, 7 persons exceeded the annual dose limit of 20 mSv, i.e. two cases per 100,000 monitored persons. The collective dose of the monitored persons decreased to 38.5 Person-Sv, the lowest value since the last fifty years of occupational dose monitoring. In 2010, 45 airlines calculated the route doses of 39,000 members of the aircraft crew personnel by using certified computer programmes for dose calculation and sent the accumulated monthly doses via the Federal Office for Civil Aviation (''Luftfahrt-Bundesamt, LBA'') to the BfS. The collective dose of the aircraft crew personnel is 83 person-Sv, and thus significantly higher than the total collective dose of the workers monitored with personal dosemeters (38.5 person-Sv). The annual average dose of aircraft crew personnel was 2.12 mSv and decreased compared to 2010 (2,30 mSv). In 2011

  1. EVALUATION OF A PERSONAL NEPHELOMETER FOR HUMAN EXPOSURE MONITORING

    Science.gov (United States)

    Current particulate matter (PM) exposure studies are using continuous personal nephelometers (pDR-1000, MIE, Inc.) to measure human exposure to PM. The personal nephelometer is a passive sampler which uses light scattering technology to measure particles ranging in size from 0....

  2. Peculiarities of gastrointestinal disease concomitant to heart connective tissue dysplasia in children born from persons exposed to ionizing radiation in childhood after the ChNPP accident

    International Nuclear Information System (INIS)

    Kondrashova, V.G.; Kolpakov, Yi.Je.; Vdovenko, V.Yu.; And Others

    2014-01-01

    UGITD namely chronic gastroduodenitis with typically concomitant involvement of several parts of digestive tract are most prevalent within all digestive system diseases in remote period upon the Chornobyl disaster in children born from persons exposed to ionizing radiation in a childhood. Presentation of UGITD occurs earlier in children suffering HCTDS with evident systemic pattern of organ and system injury along with an age. Refluxes of various nature and localization are the leading factors for UGITD onset in children suffering HCTDS. Thus a range of multidirectional tools of reflux disease prophylaxis is required for inclusion to the disease management

  3. Practical consequences for the use of a personal dosimeter for fast neutrons based on CR39 exposed up to one year

    International Nuclear Information System (INIS)

    Boschung, Markus; Fiechtner, Annette; Mayer, Sabine; Wernli, Christian

    2008-01-01

    Full text: At the Paul Scherrer Institut a personal neutron dosimetry system based on chemically etched CR-39 detectors and automatic track counting is in routine use since 1998. In its original design, the dosimeter is sensitive to thermal neutrons and to neutrons in the energy range from 200 keV up to several MeV. The standard exposition period is 3 months. Recently, a novel concept for individual monitoring was implemented at CERN. In this concept, each worker who possibly enters a radiation zone is equipped with a combined dosimeter for the measurement of personal photon and neutron doses. The dosimeter for photon dose measurement has an instant readout capability and dose measurements are done monthly. The dosimeter for neutron measurement is based on CR-39 detectors and is sensitive to fast neutrons only. The CR-39 detector is only evaluated and a neutron dose determined if the monthly personal photon dose exceeds 2 mSv or if the exposition period of the neutron dosimeter exceeds one year. This novel regime of use of the neutron dosimeter has had some important consequences for its practical implementation. A priori, the wearing period of a neutron dosimeter is not known and can range from 1 month up to 12 or even more months. A good knowledge of the long-term behaviour and characteristics of the detector material is needed. But also organisational and administrative issues have to be considered. The paper will outline the adopted procedure covering not only technical but also organisational aspects. The long-term behaviour of background track density and response to 241 Am-Be over one year are described as well as calibrations performed with 241 Am-Be and 252 Cf sources and in the High-Energy Reference Field Facility at CERN (CERF). The concept of individual monitoring at CERN could be transferred to other locations with high energy accelerators such as PSI and DESY. The experience gained with the neutron dosimeter based on CR-39 since introduction of the

  4. Psychiatric symptomatology in persons with organic solvent exposure.

    Science.gov (United States)

    Morrow, L A; Kamis, H; Hodgson, M J

    1993-02-01

    This study investigated psychiatric symptomatology, self-concept, locus of control, and daily events in persons with a history of exposure to mixtures of organic solvents. Exposed subjects were more likely than controls to report depression, anxiety, fatigue, confusion, and somatic concerns, which in turn were associated with certain exposure-related variables (e.g., cacosmia). There were no differences between the groups in self-concept, locus of control, or ratings of daily hassles and uplifts. Exposed persons may be able to accurately identify what they perceive as changes that are due to the exposure (e.g., anxiety) without attributing these specific adverse outcomes to dispositional variables.

  5. COMPASS: an Interoperable Personal Health System to Monitor and Compress Signals in Chronic Obstructive Pulmonary Disease

    Directory of Open Access Journals (Sweden)

    Thomas Hofer

    2015-11-01

    Full Text Available In the past years the progress on the mobile market has made possible an advancement in terms of telemedicine systems and definition of systems for monitoring chronic illnesses. The distribution of mobile devices in developed countries is increasing. Many of these devices are equipped with wireless standards including Bluetooth and the amount of sold Smartphones is constantly increasing. Our approach is oriented towards this market, using existing devices to enable in-home patient monitoring and even further to ubiquitious monitoring. The idea is to increase the quality of care, reduce costs and gather medical grade data, especially vital signs, with a resolution of minutes or even less, which is nowadays only possible in an ICU (Intensive Care Units. In this paper we will present the COMPASS personal health system (PHS platform, and how this platform enables Android devices to collect, analyze and send sensor data to an observation storage by means of interoperability standards. Furthermore, we will also present how this data can be compressed using advanced compressed sensing techniques and how to optimize these techniques with genetic algorithms to improve the RMSE of the reconstructed signal after compression. We also produce a preliminary evaluation of the algorithm against the state of the art algorithms for compressed sensing.

  6. Clinical course of brain stroke in the persons exposed to ionizing radiation under the production conditions

    International Nuclear Information System (INIS)

    Bouchmanov, A.

    2000-01-01

    The purpose was to study the risk factors and clinical course of brain strokes in professionally exposed workers being employed in plutonium production in comparison with a control group. The method and materials of study -clinical supervision and clinical database creation on 162 cases of brain stroke (128 males and 34 females) developed among professionally exposed workers. Age of patient varied from 21 to 68 years (in average -51.6 y.). The control group consisted of patients with the same diagnosis, worked on the same enterprise, but non-exposed to radiation. Data on the totally accumulated dose of external gamma radiation were received on the base of the individual dosimeters (from 0.1 cSv to 52 cSv, in average about 13 cSv); the plutonium-239 body content was estimated accordingly to the level of urine radionuclide excretion (from 0.4 kBq to 1.6 kBq, in average about 0.33 kBq). Muscle's hypertinsion and pathological great-toe reflexes in paretic legs and hands, hemianopsia, impressive and ataxic aphasia prevailed in the patients with ischemic brain strokes in system of internal carotid artery, exposed to radiation. The changes of muscle's tension, ataxia and nystagmus were marked more often in the professionals with ischemic brain strokes in system of vertebrobasilar artery. The illness proceeded more easy and with smaller frequency of frustration of consciousness and algesthesia, irrespective of a type ischemic brain strokes in the people exposed to ionizing radiation, than in patients of non-irradiated group. It was found that the arterial hypertension appeared to be the main risk factor for the brain stroke in both groups of patients (in 81.48% and 91.15% of cases). There was no marked differences in significance of risk factors and in main clinical parameters of various types of ischemic brain strokes among the patients professionally exposed to radiation in comparison with a control group. (author)

  7. Clinical course of brain stroke in the persons exposed to ionizing radiation under the production conditions

    Energy Technology Data Exchange (ETDEWEB)

    Bouchmanov, A. [State Research Center of Russia, Moscow (Russian Federation). Inst. of Biophysics

    2000-05-01

    The purpose was to study the risk factors and clinical course of brain strokes in professionally exposed workers being employed in plutonium production in comparison with a control group. The method and materials of study -clinical supervision and clinical database creation on 162 cases of brain stroke (128 males and 34 females) developed among professionally exposed workers. Age of patient varied from 21 to 68 years (in average -51.6 y.). The control group consisted of patients with the same diagnosis, worked on the same enterprise, but non-exposed to radiation. Data on the totally accumulated dose of external gamma radiation were received on the base of the individual dosimeters (from 0.1 cSv to 52 cSv, in average about 13 cSv); the plutonium-239 body content was estimated accordingly to the level of urine radionuclide excretion (from 0.4 kBq to 1.6 kBq, in average about 0.33 kBq). Muscle's hypertinsion and pathological great-toe reflexes in paretic legs and hands, hemianopsia, impressive and ataxic aphasia prevailed in the patients with ischemic brain strokes in system of internal carotid artery, exposed to radiation. The changes of muscle's tension, ataxia and nystagmus were marked more often in the professionals with ischemic brain strokes in system of vertebrobasilar artery. The illness proceeded more easy and with smaller frequency of frustration of consciousness and algesthesia, irrespective of a type ischemic brain strokes in the people exposed to ionizing radiation, than in patients of non-irradiated group. It was found that the arterial hypertension appeared to be the main risk factor for the brain stroke in both groups of patients (in 81.48% and 91.15% of cases). There was no marked differences in significance of risk factors and in main clinical parameters of various types of ischemic brain strokes among the patients professionally exposed to radiation in comparison with a control group. (author)

  8. Real-Time Monitoring of Occupants’ Thermal Comfort through Infrared Imaging: A Preliminary Study

    Directory of Open Access Journals (Sweden)

    Boris Pavlin

    2017-02-01

    Full Text Available Thermally comfortable indoor environments are of great importance, as modern lifestyles often require people to spend more than 20 h per day indoors. Since most of the thermal comfort models use a variety of different environmental and personal factors that need to be measured or estimated, real-time and continuous assessment of thermal comfort is often not practically feasible. This work presents a cheap and non-invasive approach based on infrared imaging for monitoring the occupants’ thermal sensation and comfort in real time. Thanks to a mechatronic device developed by the authors, the imaging is performed on the forehead skin, selected because it is always exposed to the environment and, thus, facilitating the monitoring activity in a non-invasive manner. Tests have been performed in controlled conditions on ten subjects to assess the hypothesis that the forehead temperature is correlated with subjects’ thermal sensation. This allows the exploitation of this quantity as a base for a simple monitoring of thermal comfort, which could later be tuned with an extensive experimental campaign.

  9. Monitoring Intracellular Redox Changes in Ozone-exposed airway epithelial cells

    Science.gov (United States)

    Background: The toxicity of many compounds involves oxidative injury to cells. Direct assessment of mechanistic events involved in xenobiotic-induced oxidative stress is not easily achievable. Development of genetically-encoded probes designed for monitoring intracellular redox s...

  10. Radioactive surface contamination monitors

    International Nuclear Information System (INIS)

    Aoyama, Kei; Minagoshi, Atsushi; Hasegawa, Toru

    1994-01-01

    To reduce radiation exposure and prevent contamination from spreading, each nuclear power plant has established a radiation controlled area. People and articles out of the controlled area are checked for the surface contamination of radioactive materials with surface contamination monitors. Fuji Electric has repeatedly improved these monitors on the basis of user's needs. This paper outlines typical of a surface contamination monitor, a personal surface contamination monitor, an article surface contamination monitor and a laundry monitor, and the whole-body counter of an internal contamination monitor. (author)

  11. Evaluation of chromosome aberration and micronucleus frequencies in blood lymphocytes of workers exposed to low concentrations of benzene.

    Science.gov (United States)

    Lovreglio, Piero; Maffei, Francesca; Carrieri, Mariella; D'Errico, Maria N; Drago, Ignazio; Hrelia, Patrizia; Bartolucci, Giovanni B; Soleo, Leonardo

    2014-08-01

    The frequency of chromosome aberrations (CA) and micronuclei (MN) was investigated in the peripheral lymphocytes of workers occupationally exposed to low or very low concentrations of benzene. The study included 43 exposed workers (all males), namely 19 fuel-tanker drivers and 24 filling-station attendants, and 31 male subjects with no occupational exposure to the toxicant (controls). Benzene exposure was verified by means of environmental monitoring with passive personal samplers (Radiello(®)), and through biological monitoring, i.e. by measurement of urinary trans,trans-muconic acid, S-phenylmercapturic acid and benzene. The frequency of CA and MN in peripheral lymphocytes was determined according to standard procedures. Exposure to benzene was found to be significantly higher for fuel-tanker drivers (median 246.6 μg/m(3)) than for filling-station attendants (median 19.9 μg/m(3)). Both groups had significantly higher exposure than controls (median 4.3 μg/m(3)). No increased frequency of CA and MN was observed in either fuel-tanker drivers or filling-station attendants compared with controls. In all subjects examined as a single group, the frequency of MN was significantly dependent on age. Only in the fuel-tanker drivers was the frequency of MN found to depend not only on age, but also on exposure to benzene. In conclusion, the frequency of MN, but not of CA, could be influenced by exposure to benzene concentrations of up to one order of magnitude lower than the threshold limit value (time-weighted average). Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Self-Monitoring and the Metatraits.

    Science.gov (United States)

    Wilmot, Michael P; DeYoung, Colin G; Stillwell, David; Kosinski, Michal

    2016-06-01

    Prior attempts at locating self-monitoring within general taxonomies of personality traits have largely proved unsuccessful. However, past research has typically neglected (a) the bidimensionality of the Self-Monitoring Scale and (b) the hierarchical nature of personality. The objective of this study was to test hypotheses that the two self-monitoring factors are located at the level of the metatraits. Using data from two large multi-informant samples, one community (Sample 1: N = 552, Mage  = 51.26, 61% female; NPeers  = 1,551, Mage  = 48.61, 37% female) and one online (Sample 2: N = 3,726, Mage  = 24.89, 59% female; NPeers  = 17,868, Mage  = 26.23, 64% female), confirmatory factor analysis was used to test the hypotheses. Results confirmed hypotheses that acquisitive self-monitoring would have a strong positive relation to metatrait Plasticity, whereas protective self-monitoring would have a moderate negative relation to metatrait Stability. In both samples, constraining the correlation between acquisitive self-monitoring and Plasticity to unity did not alter model fit indices, indicating that the two putatively distinct constructs are identical. Findings have wide-ranging implications, including integration of the construct of self-monitoring into the mainstream of personality research, as the latter moves toward the development of broad explanatory theories. © 2015 Wiley Periodicals, Inc.

  13. Recommendations on health care and medical monitoring to the governments of Belarus, Russian Federation and Ukraine

    International Nuclear Information System (INIS)

    Repacholi, M.; Carr, Z.

    2005-01-01

    The following recommendations on health care and medical monitoring to the governments of Belarus, Russian Federation and Ukraine were presented: Continue annual medicals, including cardiovascular exams, on ARS survivors. Reconsider medical follow-up of persons exposed to < 1 Gy. Such follow-up programs are very unlikely to be cost-effective use funds saved to improve general health care programs, continue thyroid cancer screening for adults exposed as children, but evaluate this at intervals for cost-benefit and expected number of cases. Maintain high quality cancer registries to assist allocate public health resources and research. Monitor incidence rates of childhood leukaemia in highly exposed populations. Continue eye examinations in highly exposed populations; new information on radiation-induced cataracts at lower doses may come. Continue local registers on reproductive effects; may not be useful for research but may reassure the population. Inform local populations of the Forum results, including through health care professionals Chernobyl. Some key questions to follow-up: What will be the incidence of various cancers in highly exposed Chernobyl populations (emergency workers and resident of highly contaminated territories)? Will there be an excess risk of thyroid cancers in adults? What are the uncertainties in the estimates of thyroid doses? What is the role of radiation on the induction of cardiovascular disease? Studies should be conducted under a joint protocol with the 3 affected countries participating cooperatively. What is the effect of high doses of radiation on the immune. WHO will continue to participate in activities related to the health consequences and research. The Chernobyl Forum's goals of providing scientifically sound information and recommendations to the affected governments on how to provide more effective health care is a good model that should be used for other large accident areas

  14. Brain Activation in Response to Personalized Behavioral and Physiological Feedback From Self-Monitoring Technology: Pilot Study.

    Science.gov (United States)

    Whelan, Maxine E; Morgan, Paul S; Sherar, Lauren B; Kingsnorth, Andrew P; Magistro, Daniele; Esliger, Dale W

    2017-11-08

    The recent surge in commercially available wearable technology has allowed real-time self-monitoring of behavior (eg, physical activity) and physiology (eg, glucose levels). However, there is limited neuroimaging work (ie, functional magnetic resonance imaging [fMRI]) to identify how people's brains respond to receiving this personalized health feedback and how this impacts subsequent behavior. Identify regions of the brain activated and examine associations between activation and behavior. This was a pilot study to assess physical activity, sedentary time, and glucose levels over 14 days in 33 adults (aged 30 to 60 years). Extracted accelerometry, inclinometry, and interstitial glucose data informed the construction of personalized feedback messages (eg, average number of steps per day). These messages were subsequently presented visually to participants during fMRI. Participant physical activity levels and sedentary time were assessed again for 8 days following exposure to this personalized feedback. Independent tests identified significant activations within the prefrontal cortex in response to glucose feedback compared with behavioral feedback (Pbrain activation when compared with behavior. Participants reduced time spent sedentary at follow-up. Research on deploying behavioral and physiological feedback warrants further investigation. ©Maxine E Whelan, Paul S Morgan, Lauren B Sherar, Andrew P Kingsnorth, Daniele Magistro, Dale W Esliger. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 08.11.2017.

  15. A portable battery powered microfluidic impedance cytometer with smartphone readout: towards personal health monitoring.

    Science.gov (United States)

    Talukder, Niloy; Furniturewalla, Abbas; Le, Tuan; Chan, Matthew; Hirday, Shreyas; Cao, Xinnan; Xie, Pengfei; Lin, Zhongtian; Gholizadeh, Azam; Orbine, Steve; Javanmard, Mehdi

    2017-06-01

    We present a portable system for personalized blood cell counting consisting of a microfluidic impedance cytometer and portable analog readout electronics, feeding into an analog-to-digital converter (ADC), and being transmitted via Bluetooth to a user-accessible mobile application. We fabricated a microfluidic impedance cytometer with a novel portable analog readout. The novel design of the analog readout, which consists of a lock-in-amplifier followed by a high-pass filter stage for subtraction of drift and DC offset, and a post-subtraction high gain stage, enables detection of particles and cells as small as 1 μm in diameter, despite using a low-end 8-bit ADC. The lock-in-amplifier and the ADC were set up to receive and transmit data from a Bluetooth module. In order to initiate the system, as well as to transmit all of the data, a user friendly mobile application was developed, and a proof-of-concept trial was run on a blood sample. Applications such as personalized health monitoring require robust device operation and resilience to clogging. It is desirable to avoid using channels comparable in size to the particles being detected thus requiring high levels of sensitivity. Despite using low-end off-the-shelf hardware, our sensing platform was capable of detecting changes in impedance as small as 0.032%, allowing detection of 3 μm diameter particles in a 300 μm wide channel. The sensitivity of our system is comparable to that of a high-end bench-top impedance spectrometer when tested using the same sensors. The novel analog design allowed for an instrument with a footprint of less than 80 cm 2 . The aim of this work is to demonstrate the potential of using microfluidic impedance spectroscopy for low cost health monitoring. We demonstrated the utility of the platform technology towards cell counting, however, our platform is broadly applicable to assaying wide panels of biomarkers including proteins, nucleic acids, and various cell types.

  16. Career Success: The Effects of Personality.

    Science.gov (United States)

    Lau, Victor P.; Shaffer, Margaret A.

    1999-01-01

    A model based on Bandura's Social Learning Theory proposes the following personality traits as determinants of career success: locus of control, self-monitoring, self-esteem, and optimism, along with job performance and person-to-environment fit. (SK)

  17. Security And Privacy Issues in Healthcare Monitoring Systems: A Case Study

    DEFF Research Database (Denmark)

    Handler, Daniel Tolboe; Hauge, Lotte; Spognardi, Angelo

    2017-01-01

    Security and privacy issues are rarely taken into account in automated systems for monitoring elderly people in their home, exposing inhabitants to a number of threats they are usually not aware of. As a case study to expose the major vulnerabilities these systems are exposed to, this paper reviews...... a generic example of automated healthcare monitoring system. The security and privacy issues identified in this case study can be easily generalised and regarded as alarm bells for all the pervasive healthcare professionals....

  18. Radiation area monitoring by wireless-communicating area monitor with surveillance camera

    International Nuclear Information System (INIS)

    Shimura, Mitsuo; Kobayashi, Hiromitsu; Kitahara, Hideki; Kobayashi, Hironobu; Okamoto, Shinji

    2004-01-01

    Aiming at a dose reduction and a work efficiency improvement for nuclear power plants that have high dose regions, we have developed our system of wireless-communicating Area Monitor with Surveillance Camera, and have performed an on-site test. Now we are implementing this Area Monitor with Surveillance Camera for a use as a TV camera in the controlled-area, which enables a personal computer to simultaneously display two or more dose values and site live images on the screen. For the radiation detector of this Area Monitor System, our wireless-communicating dosimeter is utilized. Image data are transmitted via a wireless Local Area Network (LAN). As a test result, image transmission of a maximum of 20 frames per second has been realized, which shows that this concept is a practical application. Remote-site monitoring also has been realized from an office desk located within the non-controlled area, adopting a Japan's wireless phone system, PHS (Personal Handy Phone) for the transmission interface. (author)

  19. Neurophysiological evidence of impaired self-monitoring in schizotypal personality disorder and its reversal by dopaminergic antagonism.

    Science.gov (United States)

    Rabella, Mireia; Grasa, Eva; Corripio, Iluminada; Romero, Sergio; Mañanas, Miquel Àngel; Antonijoan, Rosa M; Münte, Thomas F; Pérez, Víctor; Riba, Jordi

    2016-01-01

    Schizotypal personality disorder (SPD) is a schizophrenia-spectrum disorder characterized by odd or bizarre behavior, strange speech, magical thinking, unusual perceptual experiences, and social anhedonia. Schizophrenia proper has been associated with anomalies in dopaminergic neurotransmission and deficits in neurophysiological markers of self-monitoring, such as low amplitude in cognitive event-related brain potentials (ERPs) like the error-related negativity (ERN), and the error positivity (Pe). These components occur after performance errors, rely on adequate fronto-striatal function, and are sensitive to dopaminergic modulation. Here we postulated that analogous to observations in schizophrenia, SPD individuals would show deficits in self-monitoring, as measured by the ERN and the Pe. We also assessed the capacity of dopaminergic antagonists to reverse these postulated deficits. We recorded the electroencephalogram (EEG) from 9 SPD individuals and 12 healthy controls in two separate experimental sessions while they performed the Eriksen Flanker Task, a classical task recruiting behavioral monitoring. Participants received a placebo or 1 mg risperidone according to a double-blind randomized design. After placebo, SPD individuals showed slower reaction times to hits, longer correction times following errors and reduced ERN and Pe amplitudes. While risperidone impaired performance and decreased ERN and Pe in the control group, it led to behavioral improvements and ERN amplitude increases in the SPD individuals. These results indicate that SPD individuals show deficits in self-monitoring analogous to those in schizophrenia. These deficits can be evidenced by neurophysiological measures, suggest a dopaminergic imbalance, and can be reverted by dopaminergic antagonists.

  20. Real-Time Personalized Monitoring to Estimate Occupational Heat Stress in Ambient Assisted Working

    Directory of Open Access Journals (Sweden)

    Pablo Pancardo

    2015-07-01

    Full Text Available Ambient Assisted Working (AAW is a discipline aiming to provide comfort and safety in the workplace through customization and technology. Workers’ comfort may be compromised in many labor situations, including those depending on environmental conditions, like extremely hot weather conduces to heat stress. Occupational heat stress (OHS happens when a worker is in an uninterrupted physical activity and in a hot environment. OHS can produce strain on the body, which leads to discomfort and eventually to heat illness and even death. Related ISO standards contain methods to estimate OHS and to ensure the safety and health of workers, but they are subjective, impersonal, performed a posteriori and even invasive. This paper focuses on the design and development of real-time personalized monitoring for a more effective and objective estimation of OHS, taking into account the individual user profile, fusing data from environmental and unobtrusive body sensors. Formulas employed in this work were taken from different domains and joined in the method that we propose. It is based on calculations that enable continuous surveillance of physical activity performance in a comfortable and healthy manner. In this proposal, we found that OHS can be estimated by satisfying the following criteria: objective, personalized, in situ, in real time, just in time and in an unobtrusive way. This enables timely notice for workers to make decisions based on objective information to control OHS.

  1. Cytogenetic follow-up of patients exposed, 7.5 years after radiological accident in Goiania, Brazil

    International Nuclear Information System (INIS)

    Ramalho, Adriana T.

    1996-01-01

    Ten persons exposed to 137 Cs during the radiological accident in Goiania (Brazil) were reexamined for the frequency of unstable chromosomal aberrations (dicentric chromosomes, centric rings and acentric fragments) 7.5 years the first examination. It was found that the frequencies fell to about 5% of the initial values, for those individuals who had been exposed to moderate to high doses. For the subjects exposed to low doses, of the order of 0.2 Gy or less., the observed frequencies of chromosomal aberrations fell much more slowly. (author)

  2. Effectiveness of a personalized ventilation system in reducing personal exposure against directly released simulated cough droplets.

    Science.gov (United States)

    Pantelic, J; Tham, K W; Licina, D

    2015-12-01

    The inhalation intake fraction was used as an indicator to compare effects of desktop personalized ventilation and mixing ventilation on personal exposure to directly released simulated cough droplets. A cough machine was used to simulate cough release from the front, back, and side of a thermal manikin at distances between 1 and 4 m. Cough droplet concentration was measured with an aerosol spectrometer in the breathing zone of a thermal manikin. Particle image velocimetry was used to characterize the velocity field in the breathing zone. Desktop personalized ventilation substantially reduced the inhalation intake fraction compared to mixing ventilation for all investigated distances and orientations of the cough release. The results point out that the orientation between the cough source and the breathing zone of the exposed occupant is an important factor that substantially influences exposure. Exposure to cough droplets was reduced with increasing distance between cough source and exposed occupant. The results from this study show that an advanced air distribution system such as personalized ventilation reduces exposure to cough-released droplets better than commonly applied overhead mixing ventilation. This work can inform HVAC engineers about different aspects of air distribution systems’ performance and can serve as an aid in making critical design decisions. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Monitoring mutations in people: an in vivo study of people accidentally or occupationally exposed to ionizing radiation

    International Nuclear Information System (INIS)

    Glickman, B.W.

    1996-01-01

    Recent developments in molecular biology and medicine now permit the monitoring of mutation in humans 'in vivo'. The most commonly used approach, and the main one reported in this paper, is the study of mutations at the hypoxanthine phosphoribosyl transferase (hprt) locus in peripheral T-lymphocytes. This paper deals with evidence from the radiological accident in Goiania, Brazil (where several hundred people were accidentally exposed to cesium-137), from a study of Soviet cosmonauts, and from monozygotic twins. The conclusions from Brazil are: mutation at hprt increases with age and is higher in smokers; in adults a linear dose response was found; no radiation-induced mutational fingerprint was found; children are particularly sensitive; the level of mutation dropped over several years (probably reflecting natural T-cell turnover). The conclusions from cosmonauts are: each cosmonaut had a significantly above-average level of mutation, but this may not be due to radiation at all; no 'fingerprint' was found, and there was no apparent dependence on dose. The study of twins showed a very strong correlation of mutant frequencies between one twin and the other, but this correlation decreased with age, presumably due to environmental effects. 1 tab., 2 figs

  4. Medical care for occupational exposed personnel by authorized physicians; Arbeitsmedizinische Betreuung beruflich strahlenexponierter Personen durch ermaechtigte Aerzte

    Energy Technology Data Exchange (ETDEWEB)

    List, Volker [KIT - Karlsruher Institut fuer Technologie Medizinische Dienste, Eggenstein-Leopoldshafen (Germany). Liaison Institute der Weltgesundheitsorganisation (WHO)

    2017-07-01

    Since 2009 new scientific results and respective publications few changes in the legal regulations concerning the medical care for exposed occupational personnel occurred. These changes include the careful attention of ethical aspects and the efficiency control of radiation protection measures. In Switzerland the medical surveillance of occupational exposed persons has been terminated.

  5. Radiation Exposure Monitoring and Information Transmittal (REMIT) system

    International Nuclear Information System (INIS)

    Cale, R.; Clark, T.; Dixson, R.; Hagemeyer, D.

    1993-06-01

    The Radiation Exposure Monitoring and Information Transmittal (REMIT) system is designed to assist US Nuclear Regulatory Commission (NRC)licensees in meeting the reporting requirements of the revised 10 CFR 20 and in agreement with the guidance contained in R.G. 8.7, Rev. 1, ''Instructions for Recording and Reporting Occupational Exposure Data.'' REMIT is a personal computer (PC) based menu driven system that facilitates the manipulation of data base files to record and report radiation exposure information. REMIT is designed to be user-friendly and contains the full text of R. G. 8.7, Rev. 1, on-line as well as context-sensitive help throughout the program. The user can enter data directly from NRC Forms 4 or 5, REMIT allows the user to view the individual's exposure in relation to regulatory or administrative limits and alerts the user to exposures in excess of these limits. The system also provides for the calculation and summation of dose from intakes and the determination of the dose to the maximally exposed extremity for the monitoring year. REMIT can produce NRC Forms 4 and 5 in paper and electronic format and can import/export data from ASCII and data base files

  6. Micronuclei in cytokinesis-blocked lymphocytes of medical personnel occupationally exposed to ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Noditi, M.; Draghia, L.; Popescu, D. [Institute of Public Health ' Prof. Dr. Leonida Georgescu' Timisoara (Romania); Cincu, E. [University of Agriculture Sciences of Banat, Timisoara (Romania)

    2006-07-01

    Bio monitoring of occupational exposures relies on surveillance of exposure and its biological consequences. The measurement of micronuclei in population of exposed cells is a cytogenetic end point used for estimation purposes. To ensure that only dividing cells are scored, cells are treated with cytochalasin B, which blocks cytokinesis and results in bi nucleated cells. Only the bi nucleated cells are evaluated for the formation of micronuclei. In 2004-2005 there have been analyzed and compared two groups of medical staff occupationally exposed to X-rays by using micronucleus test. The first group consisted in 9 doctors and nurses specialized in interventional cardiology from the Institute of Cardiology - Timisoara, Romania, males and females, smokers and nonsmokers. The mean age was 41.5 years and the mean duration of employment 10.6 years. According to personal dosimeters, some of them have had an overdose exposure. The other group consisted in 19 doctors and nurses from the radiology department of several hospitals from Timisoara with the mean age of 48.3 years and the mean duration of employment of 17.8 years. According to personal dosimeters, none of them have had an overdose exposure. The recorded frequency of micronuclei was 62.6/1000 bi nucleated cells for the interventional cardiology personnel. There have been observed cells with 2, 3 and even 5 micronuclei. For the radiology department personnel the frequency of micronuclei was 15.4/1000 bi nucleated cells and the appearance of cells with more than one micronucleus was exceptional. In general, there was a tendency of accumulation of micronuclei with age but the correlation with the age of employment was rather unclear. Due to low doses exposure confounding factors could exist. For instance, a proportion of micronuclei are formed because of other mutagen factors from the environment or smoking habit. Nevertheless the exposure of interventional cardiology personnel is more consistent and further

  7. Micronuclei in cytokinesis-blocked lymphocytes of medical personnel occupationally exposed to ionizing radiation

    International Nuclear Information System (INIS)

    Noditi, M.; Draghia, L.; Popescu, D.; Cincu, E.

    2006-01-01

    Bio monitoring of occupational exposures relies on surveillance of exposure and its biological consequences. The measurement of micronuclei in population of exposed cells is a cytogenetic end point used for estimation purposes. To ensure that only dividing cells are scored, cells are treated with cytochalasin B, which blocks cytokinesis and results in bi nucleated cells. Only the bi nucleated cells are evaluated for the formation of micronuclei. In 2004-2005 there have been analyzed and compared two groups of medical staff occupationally exposed to X-rays by using micronucleus test. The first group consisted in 9 doctors and nurses specialized in interventional cardiology from the Institute of Cardiology - Timisoara, Romania, males and females, smokers and nonsmokers. The mean age was 41.5 years and the mean duration of employment 10.6 years. According to personal dosimeters, some of them have had an overdose exposure. The other group consisted in 19 doctors and nurses from the radiology department of several hospitals from Timisoara with the mean age of 48.3 years and the mean duration of employment of 17.8 years. According to personal dosimeters, none of them have had an overdose exposure. The recorded frequency of micronuclei was 62.6/1000 bi nucleated cells for the interventional cardiology personnel. There have been observed cells with 2, 3 and even 5 micronuclei. For the radiology department personnel the frequency of micronuclei was 15.4/1000 bi nucleated cells and the appearance of cells with more than one micronucleus was exceptional. In general, there was a tendency of accumulation of micronuclei with age but the correlation with the age of employment was rather unclear. Due to low doses exposure confounding factors could exist. For instance, a proportion of micronuclei are formed because of other mutagen factors from the environment or smoking habit. Nevertheless the exposure of interventional cardiology personnel is more consistent and further

  8. Radiation protection and ambient radioactivity monitoring in the area of the Asse mine. Annual report 2005

    International Nuclear Information System (INIS)

    Meyer, H.; Wanka, T.

    2006-01-01

    Radiation protection measurements in the Asse mine and its environment were continued. Programmes for monitoring off-air and the environment more or less summarize monitoring measures and measurements so far. 358 measurements were made, i.e. as many as in the year before. All values recorded were in the range of natural background activity. In some cases, also long-term effects of early nuclear weapons tests and of the Chernobyl accident were identified. All staff members were monitored in accordance with the Radiation Protection Ordinance, and local doses, local dose rates and mine air activity were recorded in the framework of occupational radiation protection. None of the measurements exceeded the permissible personal doses and activities for occulpationally exposed persons. In the off-air of the salt mine, low concentrations of H-3, C-14, Pb-10 and Rn-222 including Rn-220 as well as short-lived radon decay products were measured. Concentrations in the environment of the shaft as calculated from the annual measurements were lower in some instances than the average natural concentrations of these nuclides. Radiation exposure from emissions in the most unfavourable site in the vicinity was far below the limiting values set by the Radiation Protection Ordinance. Storage of radioactive waste and research activities in the Asse salt mine resulted in no significantly higher population exposure in the surrounding villages. (orig.)

  9. The Fee Sensitive Risk Exposures of Project Authorized Person in Hong Kong

    Directory of Open Access Journals (Sweden)

    Sai-On Cheung

    2012-11-01

    Full Text Available Authorized Persons (AP play a critical role in the design and construction of building works in Hong Kong. Under the Building Ordinance, design and construction of building works need to be coordinated and monitored by an AP registered with the Buildings Department. Professionally qualified Architects, Engineers and Surveyors are eligible to register as AP after completing the prescribed assessment. In addition, the project AP is often appointed by the project owner to be the project team leader. In these capacities, a project AP is exposed to various risks. This paper seeks to identify the fee sensitive risk exposures of project APs. Through an ANOVA study, these risks exposures are those due to liabilities under the Building Ordinance at the construction stage, those towards the third parties and the clients.

  10. Monitoring and dose recording for the individual

    International Nuclear Information System (INIS)

    1988-01-01

    This document specifies the conditions under which monitoring of individuals is required. For workers identified as Atomic Radiation Workers, determination of dose or exposure must be made. In circumstances where personal monitoring techniques are impractical, doses and exposures may be estimated by non-personal monitoring techniques. For workers not identified as Atomic Radiation Workers, licensees must be able to demonstrate that there is no reasonable potential for accumulating radiation doses or exposures in excess of regulatory limits. (L.L.)

  11. Cancer incidence and mortality among persons having been exposed to ionizing waves in a school in Val-de-Marne

    International Nuclear Information System (INIS)

    Germonneau, P.; Castor, C.

    2005-01-01

    The Marie Curie School of Nogent-Sur-Marne (Val-de-Marne, France) was built in 1969 on the site of a former radium extracting plant. Due to remaining radioactive waste in the subsoil, school staff and students who attended the school have been exposed to radiation. A retrospective cohort study was conducted on the 3,403 persons who had attended the school regularly until it closed down in 1998. The national health insurance register was used to trace people. Incidence of cancers, leukaemia and mortality were analysed. In the population of the pupils a significant excess risk for leukaemia was observed (Standardized Incidence Ratio = 4.6 IC_9_5_% [1.66 - 9.89]). These results are not conclusive because of the high proportion of those who could not be traced and were lost to any opportunity for follow-up (42%), and because of preferential recruitment due to a bias generated by the query of the records being centered on searching specifically for those who were sick. The difficulties met by the authors justify that when faced with similar problems in the future, greater attention should be paid to the feasibility study before any involvement or action. (authors)

  12. Personal history, beyond narrative

    DEFF Research Database (Denmark)

    Køster, Allan

    2017-01-01

    on a distinction between history and narrative, I outline an account of historical becoming through a process of sedimentation and a rich notion of what I call historical selfhood on an embodied level. Five embodied existentials are suggested, sketching a preliminary understanding of how selves are concretely......Narrative theories currently dominate our understanding of how selfhood is constituted and concretely individuated throughout personal history. Despite this success, the narrative perspective has recently been exposed to a range of critiques. Whilst these critiques have been effective in pointing...... out the shortcomings of narrative theories of selfhood, they have been less willing and able to suggest alternative ways of understanding personal history. In this article, I assess the criticisms and argue that an adequate phenomenology of personal history must also go beyond narrative. Drawing...

  13. Occupational radiation exposure in Germany in 2012. Report of the radiation protection register; Die berufliche Strahlenexposition in Deutschland 2012. Bericht des Strahlenschutzregisters

    Energy Technology Data Exchange (ETDEWEB)

    Frasch, Gerhard; Kammerer, Lothar; Karofsky, Ralf; Mordek, Else; Schlosser, Andrea; Spiesl, Josef

    2014-04-15

    In Germany, persons who are occupationally exposed to ionising radiation are monitored by several official dosimetry services that transmit the dose records about individual radiation monitoring to the Radiation Protection Register of the Federal Office for Radiation Protection (BfS). The purpose of the Radiation Protection Register is to supervise the keeping of the dose limits and to monitor the compliance with the radiation protection principle ''Optimisation'' by performing detailed annual statistical analyses of the monitored persons and their radiation exposure. The annual report of the Radiation Protection Register provides information about status and development of occupational radiation exposure in Germany. In 2012, about 350,000 workers were monitored with dosemeters for occupational radiation exposure. The number increased continuously by totally 10 % into the past five years. 19 % of the monitored persons received measurable personal doses. The average annual dose of these exposed workers was 0.52 mSv corresponding to 2.6 % of the annual dose limit of 20 mSv for radiation workers. In total, 2 persons exceeded the annual dose limit of 20 mSv, i.e. less than one case per 100,000 monitored persons. The collective dose of the monitored persons decreased to 27.9 Person-Sv, the lowest value since the last fifty years of occupational dose monitoring. 45 airlines calculated the route doses of 40,000 aircraft crew members by using certified computer programmes for dose calculation and sent the accumulated monthly doses via the Federal Office for Civil Aviation (''Luftfahrt-Bundesamt, LBA'') to the BfS. The collective dose of the aircraft crew personnel is 78.5 person- Sv, and thus significantly higher than the total collective dose of the workers monitored with personal dosemeters. The annual average dose of aircraft crew personnel was 1.96 mSv and decreased compared to 2011 (2.12 mSv) due to solar cycle. In 2012, about

  14. Metallothionein response in earthworms Lampito mauritii (Kinberg) exposed to fly ash

    Energy Technology Data Exchange (ETDEWEB)

    Maity, S.; Hattacharya, S.; Chaudhury, S. [Visva Bharati, Santini Ketan (India)

    2009-10-15

    Among pollutants, the coal fly ash occupies a significant position in industrial wastes. The fly ash matrix is a complex mixture of various organic (polyhalogenated compounds) and inorganic (Si, Al, Fe, As, Cd, Bi, Hg, etc.) chemicals. The application of fly ash for agricultural purposes and as landfills may lead to the contamination of the land with some of the toxic chemical compounds present in fly ash. Thus prior to the application of fly ash for developmental activities, it requires bio-monitoring and risk characterization. In order to achieve this objective adult Lampito mauritii were exposed to different proportions of fly ash in soil for 30 d and the concentrations of metallothionein in earthworm were assessed. The results revealed that up to 50% of fly ash amendment does not apparently harm the earthworm in respect of their survival and growth. A significant increase in tissue metallothionein level was recorded in L mauritii exposed to fly ash amended soil without tissue metal accumulation indicating that metallothionein is involved in scavenging of free radicals and reactive oxygen species metabolites. It is concluded that this biochemical response observed in L mauritii exposed to fly ash amended soil could be used in ecotoxicological field monitoring.

  15. Hot spring therapy of atomic bomb exposed patients, (9)

    Energy Technology Data Exchange (ETDEWEB)

    Hatta, O [Balneogic Sanatorium for the Atomic Bomb Injured Beppu, Oita (Japan); Tsuji, H

    1978-03-01

    The following description shows the statistics and the results of medical examinatin concerning the patients utilized Beppu Atomic Bomb Center from April, 1977, to March, 1978. Number of persons utilized the center was 3904, and 20285 man-days in total. Number of case treated there was 268. Number of diseases amounted to 442 of 66 sorts, excluding temporary of acute diseases such as acute entergastritis and cold diseases, etc. According to the report by the Ministry of Health and Welfare, atomic bomb-exposed persons show twice as much rate of incidence as normal persons, and owing to aging, many of them have more than two kinds of diseases. Among the diseases, 60 cases were hypertension, 32 heart disease, 30 knee-arthritis, 26 diabetes, 25 hepatitis, 23 spondylosis deformans, etc. Among 268 cases treated by hot spring therapy, 6 were totally cured, and 252 showed alleviation, while 10 showed no change.

  16. Non-thyroid cancer incidence in Belarusian residents exposed to Chernobyl fallout in childhood and adolescence: Standardized Incidence Ratio analysis, 1997–2011

    International Nuclear Information System (INIS)

    Ostroumova, Evgenia; Hatch, Maureen; Brenner, Alina; Nadyrov, Eldar; Veyalkin, Ilya; Polyanskaya, Olga; Yauseyenka, Vasilina; Polyakov, Semion; Levin, Leonid

    2016-01-01

    Background: While an increased risk of thyroid cancer from post-Chernobyl exposure to Iodine-131 (I-131) in children and adolescents has been well-documented, risks of other cancers or leukemia as a result of residence in radioactively contaminated areas remain uncertain. Methods: We studied non-thyroid cancer incidence in a cohort of about 12,000 individuals from Belarus exposed under age of 18 years to Chernobyl fallout (median age at the time of Chernobyl accident of 7.9 years). During 15 years of follow-up from1997 through 2011, 54 incident cancers excluding thyroid were identified in the study cohort with 142,968 person-years at risk. We performed Standardized Incidence Ratio (SIR) analysis of all solid cancers excluding thyroid (n=42), of leukemia (n=6) and of lymphoma (n=6). Results: We found no significant increase in the incidence of non-thyroid solid cancer (SIR=0.83, 95% Confidence Interval [CI]: 0.61; 1.11), lymphoma (SIR=0.66, 95% CI: 0.26; 1.33) or leukemia (SIR=1.78, 95% CI: 0.71; 3.61) in the study cohort as compared with the sex-, age- and calendar-time-specific national rates. These findings may in part reflect the relatively young age of study subjects (median attained age of 33.4 years), and long latency for some radiation-related solid cancers. Conclusions: We found no evidence of statistically significant increases in solid cancer, lymphoma and leukemia incidence 25 years after childhood exposure in the study cohort; however, it is important to continue follow-up non-thyroid cancers in individuals exposed to low-level radiation at radiosensitive ages. - Highlights: • We monitor cancers in a Belarusian cohort of exposed as children due to Chernobyl. • No increase in solid cancer rates was found as compared to the national rates. • An elevation of leukemia rates was detected, although statistically insignificant. • Results are consistent with those in a cohort of exposed as children in Ukraine. • Further monitoring of cancer situation

  17. Non-thyroid cancer incidence in Belarusian residents exposed to Chernobyl fallout in childhood and adolescence: Standardized Incidence Ratio analysis, 1997–2011

    Energy Technology Data Exchange (ETDEWEB)

    Ostroumova, Evgenia, E-mail: ostroumovae@iarc.fr [Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Department of Health and Human Services, 9609 Medical Center Drive, MSC 9776, Bethesda, 20892 MD (United States); Hatch, Maureen, E-mail: hatchm@mail.nih.gov [Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Department of Health and Human Services, 9609 Medical Center Drive, MSC 9776, Bethesda, 20892 MD (United States); Brenner, Alina, E-mail: brennera@mail.nih.gov [Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Department of Health and Human Services, 9609 Medical Center Drive, MSC 9776, Bethesda, 20892 MD (United States); Nadyrov, Eldar, E-mail: nadyrov2006@rambler.ru [The Republican Research Center for Radiation Medicine and Human Ecology, 290 Ilyicha Street, Gomel 246040 (Belarus); Veyalkin, Ilya, E-mail: veyalkin@mail.ru [The Republican Research Center for Radiation Medicine and Human Ecology, 290 Ilyicha Street, Gomel 246040 (Belarus); Polyanskaya, Olga, E-mail: polyanskaya@tut.by [The Republican Research Center for Radiation Medicine and Human Ecology, 290 Ilyicha Street, Gomel 246040 (Belarus); Yauseyenka, Vasilina, E-mail: yaus@mail.ru [The Republican Research Center for Radiation Medicine and Human Ecology, 290 Ilyicha Street, Gomel 246040 (Belarus); Polyakov, Semion, E-mail: spolyakov@belcmt.by [State Institution “Republican Scientific and Practical Center for Medical Technologies, Informatization, Administration and Management of Health”, 7-a Petrus Brovka Street, Minsk 220600 (Belarus); Levin, Leonid, E-mail: llevin@omr.med.by [Cancer Registry, State Establishment “N.N.Alexandrov National Cancer Center of Belarus for Oncology and Medical Radiology”, P.O., Lesnoy 223040 (Belarus); and others

    2016-05-15

    Background: While an increased risk of thyroid cancer from post-Chernobyl exposure to Iodine-131 (I-131) in children and adolescents has been well-documented, risks of other cancers or leukemia as a result of residence in radioactively contaminated areas remain uncertain. Methods: We studied non-thyroid cancer incidence in a cohort of about 12,000 individuals from Belarus exposed under age of 18 years to Chernobyl fallout (median age at the time of Chernobyl accident of 7.9 years). During 15 years of follow-up from1997 through 2011, 54 incident cancers excluding thyroid were identified in the study cohort with 142,968 person-years at risk. We performed Standardized Incidence Ratio (SIR) analysis of all solid cancers excluding thyroid (n=42), of leukemia (n=6) and of lymphoma (n=6). Results: We found no significant increase in the incidence of non-thyroid solid cancer (SIR=0.83, 95% Confidence Interval [CI]: 0.61; 1.11), lymphoma (SIR=0.66, 95% CI: 0.26; 1.33) or leukemia (SIR=1.78, 95% CI: 0.71; 3.61) in the study cohort as compared with the sex-, age- and calendar-time-specific national rates. These findings may in part reflect the relatively young age of study subjects (median attained age of 33.4 years), and long latency for some radiation-related solid cancers. Conclusions: We found no evidence of statistically significant increases in solid cancer, lymphoma and leukemia incidence 25 years after childhood exposure in the study cohort; however, it is important to continue follow-up non-thyroid cancers in individuals exposed to low-level radiation at radiosensitive ages. - Highlights: • We monitor cancers in a Belarusian cohort of exposed as children due to Chernobyl. • No increase in solid cancer rates was found as compared to the national rates. • An elevation of leukemia rates was detected, although statistically insignificant. • Results are consistent with those in a cohort of exposed as children in Ukraine. • Further monitoring of cancer situation

  18. Embodying Others in Immersive Virtual Reality: Electro-Cortical Signatures of Monitoring the Errors in the Actions of an Avatar Seen from a First-Person Perspective.

    Science.gov (United States)

    Pavone, Enea Francesco; Tieri, Gaetano; Rizza, Giulia; Tidoni, Emmanuele; Grisoni, Luigi; Aglioti, Salvatore Maria

    2016-01-13

    Brain monitoring of errors in one's own and other's actions is crucial for a variety of processes, ranging from the fine-tuning of motor skill learning to important social functions, such as reading out and anticipating the intentions of others. Here, we combined immersive virtual reality and EEG recording to explore whether embodying the errors of an avatar by seeing it from a first-person perspective may activate the error monitoring system in the brain of an onlooker. We asked healthy participants to observe, from a first- or third-person perspective, an avatar performing a correct or an incorrect reach-to-grasp movement toward one of two virtual mugs placed on a table. At the end of each trial, participants reported verbally how much they embodied the avatar's arm. Ratings were maximal in first-person perspective, indicating that immersive virtual reality can be a powerful tool to induce embodiment of an artificial agent, even through mere visual perception and in the absence of any cross-modal boosting. Observation of erroneous grasping from a first-person perspective enhanced error-related negativity and medial-frontal theta power in the trials where human onlookers embodied the virtual character, hinting at the tight link between early, automatic coding of error detection and sense of embodiment. Error positivity was similar in 1PP and 3PP, suggesting that conscious coding of errors is similar for self and other. Thus, embodiment plays an important role in activating specific components of the action monitoring system when others' errors are coded as if they are one's own errors. Detecting errors in other's actions is crucial for social functions, such as reading out and anticipating the intentions of others. Using immersive virtual reality and EEG recording, we explored how the brain of an onlooker reacted to the errors of an avatar seen from a first-person perspective. We found that mere observation of erroneous actions enhances electrocortical markers of

  19. Evaluation of the implementation and use of active personal dosimeters for neutrons in Brazil; Evaluacion de la implementacion y del uso de los dosimetros individuales activos para neutrones en el Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Castro B, C. P.; Wagner P, W.; De Souza P, K. C., E-mail: karla@ird.gov.br [Instituto de Radioprotecao e Dosimetria, Av. Salvador Allende s/n, Recreio Bandeirantes, 22780-160 Rio de Janeiro (Brazil)

    2014-08-15

    This work was conducted through of a field research based on a questionnaire sent to users of active personal dosimeters. A retrospective study of the last six years was also carried out of the services in the Neutron Metrology Laboratory (2008-2013) referent to the active personal dosimeters, taking into consideration the standards ISO-8529-3 and IEC-61526. The active personal dosimeters are defined as any instrument of individual monitoring with direct reading capacity, used by individuals exposed to ionizing radiation fields. Through research was verified that the active personal dosimeters work associated with other dosimeter types. Considering all dosimeters declared in the questionnaire, only two dosimeters (MGP brand Dmc 2000-GN model and the brand ATOMTEX model AT2503A) have conformity declaration with the international standard IEC-61526: 2005 reported by the manufacturers. (author)

  20. Out-of-home placement to age 18 years in children exposed to a postpartum mental disorder

    DEFF Research Database (Denmark)

    Vigod, Simone N; Laursen, Thomas Munk; Ranning, Anne

    2018-01-01

    comprising 1 868 467 births (1982-2012) were used to determine how the timing of maternal illness onset influences out-of-home placement risk up to age 18 years among children exposed to a maternal mental disorder. RESULTS: Compared to children unexposed to maternal mental illness, risk was higher......OBJECTIVES: Little is known about risk of custody loss or out-of-home placement among children whose mothers experience postpartum mental disorders, and whether this risk differs from that of children whose mothers had earlier onset of their mental disorder. METHODS: National Danish registers.......49/1000 person-years; 3.93, 3.50-4.41). Risk was even higher for children exposed to a maternal mental disorder when illness onset was more than 1-year predelivery (9.11/1000 person-years; 5.48, 5.32-5.66). CONCLUSION: Risk of out-home placement in children exposed to mothers with a new-onset postpartum mental...

  1. Maternal ability to take care of children exposed to HIV

    Directory of Open Access Journals (Sweden)

    Julyana Gomes Freitas

    2013-07-01

    Full Text Available OBJECTIVE: to assess the ability of mothers to take care of children exposed to HIV, using the Assessment Scale of Care Skills for Children Exposed to HIV at Birth and to check the association between the scale dimensions and maternal characteristics. METHOD: this cross-sectional study involved 62 HIV+ mothers whose children of up to one year old had been exposed to the virus at birth. The Assessment Scale of Care Skills for Children Exposed to HIV at Birth consists of 52 items and five dimensions, indicating high, moderate or low care ability. RESULTS: 72.7% of the mothers appropriately offered zidovudine syrup; 86.0% were highly skilled to prepare and administer milk formula; 44.4% were moderately able to prepare and administer complementary feeding; 76.5% revealed high ability to administer prophylactic treatment against pneumonia and 95.3% demonstrated high abilities for clinical monitoring and immunization. Significant associations were found between some maternal variables and the scale dimensions. CONCLUSION: the scale permits the assessment of maternal care delivery to these children and the accomplishment of specific child health interventions.

  2. Personal carbon monoxide exposures of preschool children in Helsinki, Finland - comparison to ambient air concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Alm, S.; Mukala, K.; Tittanen, P.; Jantunen, M.J. [KTL National Public Health Institute, Kuopio (Finland). Dept. of Environmental Health

    2001-07-01

    The associations of personal carbon monoxide (CO) exposures with ambient air CO concentrations measured at fixed monitoring sites, were studied among 194 children aged 3-6yr in four downtown and four suburban day-care centers in Helsinki, Finland. Each child carried a personal CO exposure monitor between 1 and 4 times for a time period of between 20 and 24h. CO concentrations at two fixed monitoring sites were measured simultaneously. The CO concentrations measured at the fixed monitoring sites were usually lower (mean maximum 8-h concentration: 0.9 and 2.6mgm{sup -3}) than the personal CO exposure concentrations (mean maximum 8-h concentration: 3.3mgm{sup -3}).The fixed site CO concentrations were poor predictors of the personal CO exposure concentrations. However, the correlations between the personal CO exposure and the fixed monitoring site CO concentrations increased (-0.03 -- -0.12 to 0.13-0.16) with increasing averaging times from 1 to 8h. Also, the fixed monitoring site CO concentrations explained the mean daily or weekly personal CO exposures of a group of simultaneously measured children better than individual exposure CO concentrations. This study suggests that the short-term CO personal exposure of children cannot be meaningfully assessed using fixed monitoring sites. (author)

  3. Personalized medicine: genome, e-health and intelligent systems. Part 1. Genomics and monitoring of clinical data

    Directory of Open Access Journals (Sweden)

    B. A. Kobrinskii

    2017-01-01

    Full Text Available The transition to personalized medicine in practical terms should combine the solution of the genomics problems as the basis for possible diseases and phenotypic manifestations that are markers and early signs of emerging pathological changes. Most diseases have their first principles in childhood. Therefore, in all age groups, it is necessary to monitor the minimum deviations and their dynamics, use mobile devices for this purpose and accumulate the received data. Processing big data (Big Data will provide more informative information. On this basis it will be possible to identify analogs for targeted therapy in similar variants of diseases in large databases of publications on the problem of interest.

  4. A cytogenetic study of hospital workers occupationally exposed to radionuclides in Serbia. Premature centromere division as novel biomarker of exposure?

    Energy Technology Data Exchange (ETDEWEB)

    Pajic, Jelena; Rakic, Boban [Serbian Institute of Occupational Health ' ' Dr Dragomir Karajovic' ' , Belgrade (Serbia). Biodosimetry Dept.; Jovicic, Dubravka [Univ. ' ' Singidunum' ' , Belgrade (Serbia). Genotoxicology Dept.; Milovanovic, Aleksandar [Serbian Institute of Occupational Health ' ' Dr Dragomir Karajovic' ' , Belgrade (Serbia). Biodosimetry Dept.; Belgrade Univ. (Serbia). Occupational Health Dept.

    2016-04-15

    The health risk of chronic exposure to radionuclides includes changes in the genome (e.g., chromosomal aberrations and micronuclei) that increase chromosomal instability. There are also other phenomena, which seem to appear more frequently in metaphases of exposed persons (such as premature centromere division). The aim of this study was to discover whether or not there is correlation between incidence of named cytogenetic changes in persons occupationally exposed to radionuclides in comparison with unexposed control group, and if significant correlation is determined, can premature centromere division be consider as a biomarker of radiation exposure? The exposed group comprised 50 individuals occupationally exposed to radionuclides. The reference control group consisted of 40 unexposed individuals. Chromosomal aberrations, micronuclei and premature centromere division were analyzed according to a standard International Atomic Energy Agency protocol. Statistical analyses were performed using SPSS 17.0 statistics.The means for analyzed cytogenetic changes were significantly higher in the exposed group. Positive correlation between them was found in exposed group. Premature centromere division parameter PCD5-10 was selected as particularly suitable for separating groups (exposed/unexposed). Identification of other phenomena related to radionuclide exposure, beside well known, may clarify recent problems in radiobiology concerning the biological response to low doses of ionizing radiation and its consequences.

  5. A cytogenetic study of hospital workers occupationally exposed to radionuclides in Serbia. Premature centromere division as novel biomarker of exposure?

    International Nuclear Information System (INIS)

    Pajic, Jelena; Rakic, Boban; Jovicic, Dubravka; Milovanovic, Aleksandar; Belgrade Univ.

    2016-01-01

    The health risk of chronic exposure to radionuclides includes changes in the genome (e.g., chromosomal aberrations and micronuclei) that increase chromosomal instability. There are also other phenomena, which seem to appear more frequently in metaphases of exposed persons (such as premature centromere division). The aim of this study was to discover whether or not there is correlation between incidence of named cytogenetic changes in persons occupationally exposed to radionuclides in comparison with unexposed control group, and if significant correlation is determined, can premature centromere division be consider as a biomarker of radiation exposure? The exposed group comprised 50 individuals occupationally exposed to radionuclides. The reference control group consisted of 40 unexposed individuals. Chromosomal aberrations, micronuclei and premature centromere division were analyzed according to a standard International Atomic Energy Agency protocol. Statistical analyses were performed using SPSS 17.0 statistics.The means for analyzed cytogenetic changes were significantly higher in the exposed group. Positive correlation between them was found in exposed group. Premature centromere division parameter PCD5-10 was selected as particularly suitable for separating groups (exposed/unexposed). Identification of other phenomena related to radionuclide exposure, beside well known, may clarify recent problems in radiobiology concerning the biological response to low doses of ionizing radiation and its consequences.

  6. Dose monitoring in nuclear emergency

    International Nuclear Information System (INIS)

    Nan Hongjie; Yang Zhongping; Lei Xin

    2012-01-01

    In order to protect people from irradiation sickness and rebuild the radiation filed in nuclear emergency, personal and environmental dose need to be monitored. The application of TLD in dose monitoring is discussed in this paper. (authors)

  7. Recommending personally interested contents by text mining, filtering, and interfaces

    Science.gov (United States)

    Xu, Songhua

    2015-10-27

    A personalized content recommendation system includes a client interface device configured to monitor a user's information data stream. A collaborative filter remote from the client interface device generates automated predictions about the interests of the user. A database server stores personal behavioral profiles and user's preferences based on a plurality of monitored past behaviors and an output of the collaborative user personal interest inference engine. A programmed personal content recommendation server filters items in an incoming information stream with the personal behavioral profile and identifies only those items of the incoming information stream that substantially matches the personal behavioral profile. The identified personally relevant content is then recommended to the user following some priority that may consider the similarity between the personal interest matches, the context of the user information consumption behaviors that may be shown by the user's content consumption mode.

  8. Advanced Pulse Oximetry System for Remote Monitoring and Management

    Science.gov (United States)

    Pak, Ju Geon; Park, Kee Hyun

    2012-01-01

    Pulse oximetry data such as saturation of peripheral oxygen (SpO2) and pulse rate are vital signals for early diagnosis of heart disease. Therefore, various pulse oximeters have been developed continuously. However, some of the existing pulse oximeters are not equipped with communication capabilities, and consequently, the continuous monitoring of patient health is restricted. Moreover, even though certain oximeters have been built as network models, they focus on exchanging only pulse oximetry data, and they do not provide sufficient device management functions. In this paper, we propose an advanced pulse oximetry system for remote monitoring and management. The system consists of a networked pulse oximeter and a personal monitoring server. The proposed pulse oximeter measures a patient's pulse oximetry data and transmits the data to the personal monitoring server. The personal monitoring server then analyzes the received data and displays the results to the patient. Furthermore, for device management purposes, operational errors that occur in the pulse oximeter are reported to the personal monitoring server, and the system configurations of the pulse oximeter, such as thresholds and measurement targets, are modified by the server. We verify that the proposed pulse oximetry system operates efficiently and that it is appropriate for monitoring and managing a pulse oximeter in real time. PMID:22933841

  9. Spoiled Onions: Exposing Malicious Tor Exit Relays

    OpenAIRE

    Winter, Philipp; Lindskog, Stefan

    2014-01-01

    Several hundred Tor exit relays together push more than 1 GiB/s of network traffic. However, it is easy for exit relays to snoop and tamper with anonymised network traffic and as all relays are run by independent volunteers, not all of them are innocuous. In this paper, we seek to expose malicious exit relays and document their actions. First, we monitored the Tor network after developing a fast and modular exit relay scanner. We implemented several scanning modules for detecting common attac...

  10. The status of the nervous system of persons exposed to occupational chronic radiation (45 years of observation)

    International Nuclear Information System (INIS)

    Azizova, T.V.

    2000-01-01

    The retrospective study of a state of the nervous system in dynamics in 1090 workers of the first Russian atomic enterprise was carried out. The main unfavorable factor of occupational effect in the yearly years of work (1948-1954) was chronic external gamma-radiation in doses from 0.4 to 5.7 Gy per one year. During maximal radiation exposure a vegetative dystonia of a hypotensive type (51.8%), asthenic syndrome (35.2%) and syndrome of microorganic changes of the central nervous system (5.9%) were most frequently registered in workers. Frequency and the periods of the development of these syndromes depended on an annual exposure dose (p<0.001). Alongside with an occupational chronic exposure non-radiation factors (age at the moment of an exposure, initial state of health, intense nature of job regarding nervous loads) exerted the certain influence on the development of these neurologic syndromes. In the long-term period after an exposure the cerebrovascular diseases were most frequent. Their incidence was naturally related with the age of patients. However, it was determined that the initial clinical manifestations of a cerebral atherosclerosis in persons exposed to irradiation in doses more of 2.5 Gy/year were registered in younger age than in control group. The frequency of their development depended on an annual dose of a gamma-irradiation, age at the moment of an exposure, degree of manifestation and duration of preceding vegetative - vascular disorders. (author)

  11. Cytogenetic investigations of persons exposed to professional chronic low-dose irradiation

    International Nuclear Information System (INIS)

    Rangelov, V.; Mitev, L.; Petrunov, P.; Vesselinova, L.

    2005-01-01

    The problem of long term influence of low-doses occupational irradiation is connected with the real assessment of their consequences. The current cytogenetic investigations were done on persons working under occupational chronic external partial irradiation. Accumulated doses of external irradiation are surveyed. Data give ground for suggestion about the relationship between accumulated dose and chromosomal aberrations. The additional damage factors (diagnostic investigations, chemical substances, tobacco addict) have done the more significant influence upon aberrations appearance increasing

  12. Mindreading Dysfunction in Avoidant Personality Disorder Compared With Other Personality Disorders.

    Science.gov (United States)

    Moroni, Fabio; Procacci, Michele; Pellecchia, Giovanni; Semerari, Antonio; Nicolò, Giuseppe; Carcione, Antonino; Pedone, Roberto; Colle, Livia

    2016-10-01

    The ability to reflect on one's own states of mind and those of others (metacognition or mindreading) is strongly implicated in personality disorders (PDs). Metacognition involves different abilities, and there is evidence that specific abilities can be selectively impaired in different PDs. The purposes of this study were to compare metacognitive competence in avoidant PD (AvPD) with that in other PDs and to investigate whether there is a specific profile for AvPD. Sixty-three patients with AvPD and 224 patients with other PDs were assessed using the Metacognitive Assessment Interview. AvPD patients showed difficulties with two metacognitive functions: monitoring and decentration, even when the severity of psychopathology was controlled for. These results support the hypothesis of specific profiles of metacognitive dysfunction in different PDs and highlight a close link between impaired monitoring and decentration functions and the inhibited and withdrawn personality style typical of AvPD.

  13. CMS Dashboard Task Monitoring: A user-centric monitoring view

    International Nuclear Information System (INIS)

    Karavakis, Edward; Khan, Akram; Andreeva, Julia; Maier, Gerhild; Gaidioz, Benjamin

    2010-01-01

    We are now in a phase change of the CMS experiment where people are turning more intensely to physics analysis and away from construction. This brings a lot of challenging issues with respect to monitoring of the user analysis. The physicists must be able to monitor the execution status, application and grid-level messages of their tasks that may run at any site within the CMS Virtual Organisation. The CMS Dashboard Task Monitoring project provides this information towards individual analysis users by collecting and exposing a user-centric set of information regarding submitted tasks including reason of failure, distribution by site and over time, consumed time and efficiency. The development was user-driven with physicists invited to test the prototype in order to assemble further requirements and identify weaknesses with the application.

  14. Pathophysiology and multifactorial etiology of acquired vasospastic disease (Raynaud syndrome) in vibration-exposed workers.

    Science.gov (United States)

    Gemne, G

    1982-12-01

    The article reviews available pathophysiological evidence for a multifactorial etiology of the Raynaud type of peripheral circulation disorder in persons exposed to vibration from handheld tools and discusses the consequences this viewpoint may have for diagnostics, preventive work, and research.

  15. Understanding differences in dose-equivalents reported by passive and electronic personal dosemeters

    International Nuclear Information System (INIS)

    Perks, Christopher A.; Burgess, Peter; Smith, David; Salasky, Mark; Yahnke, Cliff

    2008-01-01

    Full text: In a number of challenging environments, clients occasionally double badge with electronic personal dosemeters (EPDs) to ensure day-to-day management of their employees personal dose-equivalent while using passive (in our case Luxel or InLight) dosemeters for monthly monitoring for approved results for dose record keeping. In some cases there have been significant differences in the cumulative doses recorded by the EPDs and the passive dosemeters. In these circumstances the passive dosemeters usually report a higher dose than the EPD by up to a factor of two, though more commonly 1.3. In this paper we describe the differences seen between EPD and passive dosemeters (in a number of countries). We then examine the possible causes for such discrepancies by comparison with published response function data available for the EPDs and Landauer dosemeters. We have undertaken a number of experiments comparing directly a number of EPDs and passive dosemeter response to a variety of energy and complex angular geometries where the two types of dosimeter have been exposed at the same time. Recommendations will be made on the appropriate use of double badging in difficult environments and interpretation of the results. (author)

  16. Cytogenetic and hematological studies in the workers occupationally exposed to low levels of ionizing radiation

    International Nuclear Information System (INIS)

    Zakeri, F.; Honarjoo, M.; Rajab pour, M.; Zahadat, A.; Ahmad pour, M.J.; Asghari, K.

    2007-01-01

    Complete text of publication follows. Objective: This study was aimed at detecting both the incidence of chromosomal aberrations and changes in the hematological parameters as biomarkers of possible radiation injury among workers occupationally exposed to low levels of ionizing radiation and detecting the dose-effect relationship. Methods: Samples of peripheral blood were collected from 38 male industrial radiographers exposed to ionizing radiation for 1-16 years and from 24 age- and sex-matched healthy blood donors without radiation history served as control group. All radiation workers were routinely monitored with film badge. Cytogenetic analysis in peripheral blood lymphocytes assessed by the conventional chromosome aberration assay and at least 200 metaphases for each person were scored. The collected blood samples were analyzed for hematological assay using an automatic analyzer Sysmex KX-21, where 14 different parameters were computerized. Mann-Whitney U test was used to compare the frequencies of the unstable aberrations and hematological parameters between test and control groups. Dose-effect relationship and the influence of age and duration of employment was tested by regression analysis. Results and conclusion: The mean frequencies of dicentric and acentric chromosome aberrations were significantly higher in the exposed group than in the control group (P< 0.0005). No correlation between chromosomal aberrations and physical dose and age was observed in the exposed group. Also there is no clear relation between chromosome damage and duration of exposure. However, the increase in chromosome aberrations in the exposed group was not followed by a corresponding hematological depression. The average values of hematological indices were within the reference levels and did not show any significant differences with control group. A tendency of decreasing the absolute lymphocyte count within the referential levels was the only hematological effect in radiation

  17. A cytogenetic bio-monitoring of industrial radiographers occupationally exposed to low levels of ionizing radiation by using CBMN assay

    International Nuclear Information System (INIS)

    Shakeri, Mahsa; Changizi, Vahid; Zakeri, Farideh; Rajabpour, Mohammad Reza; Farshidpour, Mohammad Reza

    2017-01-01

    Industrial radiography is the process of using either gamma-emitting radionuclide sources or X-ray machines to examine the safety of industrial materials. The average annual effective dose in industrial radiography is one of the highest among radiation workers. The aim of this study was to investigate the cytogenetic effects of ionizing radiation in the peripheral blood lymphocytes of 60 industrial radiographers and 40 non-exposed individuals as the control group by using cytokinesis-block micronucleus (CBMN) assay. Totally, the frequencies of micronuclei (MN), nucleoplasmic bridges (NPBs) and nuclear buds (NBUDs) were significantly higher in the industrial radiographers than in the controls (p = 0.000). The mean MN frequency per 1000 binucleated cells in the industrial radiographers with last 5-y radiation dose of >100 mSv was significantly higher than those with ≤100 mSv (34.81 ± 12.70 vs. 26.33 ± 7.940, p = 0.024). The effect of age was observed in the control group and subjects with the age of >30 y showed significantly higher MN frequency compared with the subjects with the age of ≤30 y (9.45 ± 3.710 vs. 6.81 ± 3.050, p = 0.02). No obvious trend of increased MN as a function of either duration of employment or age or smoking status was observed in the industrial radiographers. The results show the increased levels of cytogenetic damages in the industrial radiographers. Even the workers exposed to the permissible doses are subjected to elevated frequencies of DNA damages. These findings confirm the importance of cytogenetic bio-monitoring program beside physical dosimetry, surveying radiation safety of equipment and periodic training of workers for improvement of safety and radiation protection. (authors)

  18. Performance testing of UK personal dosimetry laboratories

    CERN Document Server

    Marshall, T O

    1985-01-01

    The proposed Ionising Radiations Regulations will require all UK personal dosimetry laboratories that monitor classified personnel to be approved for personal dosimetry by the Health and Safety Executive. It is suggested that these approvals should be based on general and supplementary criteria published by the British Calibration Service (BCS) for laboratory approval for the provision of personal dosimetry services. These criteria specify certain qualitative requirements and also indicate the need for regular tests of performance to be carried out to ensure constancy of dosimetric standards. This report concerns the latter. The status of the BCS criteria is discussed and the need for additional documents to cover new techniques and some modifications to existing documents is indicated. A means is described by which the technical performance of laboratories, concerned with personal monitoring for external radiations, can be assessed, both initially and ongoing. The costs to establish the scheme and operate it...

  19. The dosimeter personal use in controlled area

    International Nuclear Information System (INIS)

    Costa, R. F.

    2015-01-01

    The discovery of X-rays revolutionized medicine because it allowed a patient to be examined internally with no surgery. But also caused damage to health professionals and patients due, its oxidizing action. In the beginning of its discovery, many doctors were exposed and exposed beams to their patients for long periods of time, therefore, they developed diseases caused by radiation and the medical community realized that something was wrong. Then created a radiological protection commission to regulate its use in humans and so limit your exposure. Today we know that many companies still did not fit the standards of radiation protection. So we evaluate the technical professionals in radiology regarding the correct use of personal dosimeter, through a descriptive study with a quantitative approach, we used the information collection technique based on a questionnaire developed for this purpose which was delivered and collected personally. From this survey, we sought to assess the knowledge of the basic guidelines of radiological protection. He concluded that the majority of respondents know the rules of use of the personal dosimeter, but do not use it properly, due mainly to lack of supervision by the company, overwork and neglect. (author)

  20. Hand and foot contamination monitor

    International Nuclear Information System (INIS)

    Jakati, R.K.; Kaptral, R.S.; Ananthkrishnan, T.S.; Pansare, M.G.

    1989-01-01

    In order to make quick measurements of beta and gamma contaminations on hands and feet of personnel working in radioactive environments, hand and foot contamination monitors are widely used. This paper describes such a monitor system designed with Intel 8085 based microcomputer. The monitoring and warning system is designed to perform measurement of activity spread over surface of hands and soles of shoes or feet. Even though the system has many features to aid testing and maintainance operation, it is easy to use for unskilled persons. In order to check the contamination, the person stands on platform and inserts both his hands into detector assemblies thereby actuating the sensing switches. After a preset interval, annunciation of clean or contaminated status is declared by the system. (author)

  1. Personal dosimetry at the radiation accidents

    International Nuclear Information System (INIS)

    Perevoznikov, O.N.; Klyuchnikov, A.A.; Kanchenko, V.A.

    2007-01-01

    The radiation accidents of different types and the methods of the dosimetry used at the consequences liquidation are considered. The long-term experience of the population personal instrumental dosimetric control carrying out at the ChNPP accident consequences liquidation is widely covered in details. The concepts are stated out and the results are presented on the functioning of the created system for personal dose monitoring of the population of Ukraine irradiation. The use of the person radiation counters at the internal irradiation population and personal dose assessment is considered in details

  2. The MMPI-2 Restructured Form Personality Psychopathology Five Scales: bridging DSM-5 Section 2 personality disorders and DSM-5 Section 3 personality trait dimensions.

    Science.gov (United States)

    Finn, Jacob A; Arbisi, Paul A; Erbes, Christopher R; Polusny, Melissa A; Thuras, Paul

    2014-01-01

    This study examined in a college sample and a sample of non-treatment-seeking, trauma-exposed veterans the association between the MMPI-2 Restructured Form (MMPI-2-RF) Personality Psychopathology Five (PSY-5) Scales and DSM-5 Section 2 personality disorder (PD) criteria, the same system used in DSM-IV-TR, and the proposed broad personality trait dimensions contained in Section 3 of DSM-5. DSM-5 Section 2 PD symptoms were assessed using the SCID-II-PQ, and applying a replicated rational selection procedure to the SCID-II-PQ item pool, proxies for the DSM-5 Section 3 dimensions and select facets were constructed. The MMPI-2-RF PSY-5 scales demonstrated appropriate convergent and discriminant associations with both Section 2 PDs and Section 3 dimensions in both samples. These findings suggest the MMPI-2-RF PSY-5 scales can serve both conceptually and practically as a bridge between the DSM-5 Section 2 PD criteria and the DSM-5 Section 3 personality features.

  3. Rapid genetic erosion in pollutant-exposed experimental chironomid populations

    Energy Technology Data Exchange (ETDEWEB)

    Nowak, Carsten [Abteilung Okologie und Evolution, Institut fuer Okologie, Evolution und Diversitaet, J. W. Goethe-Universitaet Frankfurt am Main, Siesmayerstrasse 70, 60054 Frankfurt am Main (Germany)], E-mail: cnowak@senckenberg.de; Vogt, Christian [Abteilung Aquatische Okotoxikologie, Institut fuer Okologie, Evolution und Diversitaet, J. W. Goethe-Universitaet Frankfurt am Main, Siesmayerstrasse 70, 60054 Frankfurt am Main (Germany)], E-mail: vogt@bio.uni-frankfurt.de; Pfenninger, Markus [Abteilung Okologie und Evolution, Institut fuer Okologie, Evolution und Diversitaet, J. W. Goethe-Universitaet Frankfurt am Main, Siesmayerstrasse 70, 60054 Frankfurt am Main (Germany)], E-mail: pfenninger@bio.uni-frankfurt.de; Schwenk, Klaus [Abteilung Okologie und Evolution, Institut fuer Okologie, Evolution und Diversitaet, J. W. Goethe-Universitaet Frankfurt am Main, Siesmayerstrasse 70, 60054 Frankfurt am Main (Germany)], E-mail: k.schwenk@bio.uni-frankfurt.de; Oehlmann, Joerg [Abteilung Aquatische Okotoxikologie, Institut fuer Okologie, Evolution und Diversitaet, J. W. Goethe-Universitaet Frankfurt am Main, Siesmayerstrasse 70, 60054 Frankfurt am Main (Germany)], E-mail: oehlmann@bio.uni-frankfurt.de; Streit, Bruno [Abteilung Okologie und Evolution, Institut fuer Okologie, Evolution und Diversitaet, J. W. Goethe-Universitaet Frankfurt am Main, Siesmayerstrasse 70, 60054 Frankfurt am Main (Germany)], E-mail: streit@bio.uni-frankfurt.de; Oetken, Matthias [Abteilung Aquatische Okotoxikologie, Institut fuer Okologie, Evolution und Diversitaet, J. W. Goethe-Universitaet Frankfurt am Main, Siesmayerstrasse 70, 60054 Frankfurt am Main (Germany)], E-mail: oetken@bio.uni-frankfurt.de

    2009-03-15

    Few studies have evaluated how effectively environmental contamination may reduce genetic diversity of a population. Here, we chose a laboratory approach in order to test if tributyltin (TBT) exposure at environmentally relevant concentrations leads to reduced genetic variation in the midge Chironomus riparius. Two TBT-exposed and two unexposed experimental populations were reared simultaneously in the laboratory for 12 generations. We recorded several life-history traits in each generation and monitored genetic variation over time using five variable microsatellite markers. TBT-exposed strains showed increased larval mortality (treatments: 43.8%; controls: 27.8%), slightly reduced reproductive output, and delayed larval development. Reduction of genetic variation was strongest and only significant in the TBT-exposed strains (treatments: -45.9%, controls: -24.4% of initial heterozygosity) after 12 generations. Our findings document that chemical pollution may lead to a rapid decrease in genetic diversity, which has important implications for conservation strategies and ecological management in polluted environments. - Chronic TBT exposure reduces allelic variation at five variable microsatellite loci in experimental populations of Chironomus riparius.

  4. Rapid genetic erosion in pollutant-exposed experimental chironomid populations

    International Nuclear Information System (INIS)

    Nowak, Carsten; Vogt, Christian; Pfenninger, Markus; Schwenk, Klaus; Oehlmann, Joerg; Streit, Bruno; Oetken, Matthias

    2009-01-01

    Few studies have evaluated how effectively environmental contamination may reduce genetic diversity of a population. Here, we chose a laboratory approach in order to test if tributyltin (TBT) exposure at environmentally relevant concentrations leads to reduced genetic variation in the midge Chironomus riparius. Two TBT-exposed and two unexposed experimental populations were reared simultaneously in the laboratory for 12 generations. We recorded several life-history traits in each generation and monitored genetic variation over time using five variable microsatellite markers. TBT-exposed strains showed increased larval mortality (treatments: 43.8%; controls: 27.8%), slightly reduced reproductive output, and delayed larval development. Reduction of genetic variation was strongest and only significant in the TBT-exposed strains (treatments: -45.9%, controls: -24.4% of initial heterozygosity) after 12 generations. Our findings document that chemical pollution may lead to a rapid decrease in genetic diversity, which has important implications for conservation strategies and ecological management in polluted environments. - Chronic TBT exposure reduces allelic variation at five variable microsatellite loci in experimental populations of Chironomus riparius

  5. Protection of man: the exposed individual

    Energy Technology Data Exchange (ETDEWEB)

    Bohnstedt, A.; Knebel, J.U. [Programme Nuclear Safety Research, Karlsruhe Institute of Technology, Herrmann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Breustedt, B. [Institute for Radiation Research, Karlsruhe Institute of Technology, Herrmann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany)

    2010-07-01

    Present methods for quantifying radiation exposure rely on a standardized reference man (75 kg) with defined average anatomical and physiological data. But individual person actually exposed differs from this idealized standard man. Therefore the focus of investigations at the Institute for Radiation Research (Institut fuer Strahlenforschung, ISF) which was founded at Karlsruhe Institute of Technology (Karlsruher Institut fuer Technologie, KIT) in 2009 is based on the vision to place the exposed individual with its anatomical and physiological particularities, under consideration of age, gender, body height, body shape and environment, in the centre of an individual-related quantification of the external and internal radiation exposure. Research work at the ISF is aiming at quantifying radiation exposure by improved determination of doses essentially caused by external radiation fields and the intake of radionuclides into the body. The three main topics of the institute are - external dosimetry (e.g. using a (voxel) model of the hand to simulate skin dose distribution); - internal dosimetry (e.g. body size related efficiency calibration of in-vivo counting equipment); - numerical methods/modeling (e.g. development of a mathematical/voxel-hybrid model of the human body). (authors)

  6. Radiation contamination monitors

    International Nuclear Information System (INIS)

    Kato, Tsutomu; Iba, Hiroshi; Sato, Hiroshi

    1999-01-01

    To make sure of no contamination on people, used articles and working uniforms coming out of the radiation controlled area, nuclear power plants are equipped with radioactive contamination monitors. This paper outlines the basic specifications and advantages of our personnel surface contamination monitors to inspect whole-body surface contamination of people coming out, article surface contamination monitors to inspect the surface and inside contamination of used articles brought out, laundry monitors to inspect surface contamination of working uniforms used in the area before and after a wash, and whole-body counters to inspect and measure the internal contamination of a person out of the area. (author)

  7. The effect of Base Transceiver Station waves on some immunological and hematological factors in exposed persons.

    Science.gov (United States)

    Taheri, Mohammad; Roshanaei, Ghodratollah; Ghaffari, Jamileh; Rahimnejad, Samira; Khosroshahi, Behzad Nazel; Aliabadi, Mohsen; Eftekharian, Mohammad Mahdi

    2017-01-01

    Since the number of mobile subscribers has significantly increased in recent years, the installation and deployment of Base Transceiver Station (BTS) antennas sending and receiving signals has become common and inevitable in different regions. In this study, we have tried to evaluate the effect of the waves on some immunological and hematological parameters in exposed individuals. In this study, the exposed and non-exposed individuals were used as the test and control groups, respectively. The test group was healthy people who resided in the vicinity of the Base Transceiver Station (BTS) antenna and received the maximum of radiation. The control group was selected from the healthy individuals that were matched with the exposed group by age. They resided in a distance of Base Transceiver Station (BTS) antenna and received the minimum of radiation. After stating complete explanations and obtaining the consent, the venous blood samples were taken from them. Then, CBC and the level of cytokines including IL-4, IL-10 and interferon γ were performed on the samples and the results were analyzed by SPSS software. In the test group, the whole number of white blood cells, the level of hematocrit, percent of monocytes, eosinophils and basophils were significantly lower than the control group. The number of red blood cells, their average volume and the mean concentration of hemoglobin were notably higher than the controls. There was not observed a significant difference between the two groups in hemoglobin, its mean concentration, platelet count, percent of lymphocytes and neutrophils as well as serum levels of cytokines IL-4, IL-10 and interferon γ . It seems that radiation of mobile phone antennas influenced the blood and immune systems, but further study should be done to exactly determine the targets.

  8. Dose estimate for personal music players including earphone sensitivity and characteristic

    DEFF Research Database (Denmark)

    Hammershøi, Dorte; Ordoñez Pizarro, Rodrigo Eduardo; Christensen, Anders Tornvig

    2016-01-01

    Personal music players can expose their listeners to high sound pressure levels over prolonged periods of time. The risk associated with prolonged listening is not readily available to the listener, and efforts are made to standardize dose estimates that may be displayed for the user. In the pres......Personal music players can expose their listeners to high sound pressure levels over prolonged periods of time. The risk associated with prolonged listening is not readily available to the listener, and efforts are made to standardize dose estimates that may be displayed for the user...... earphone measurements published in the past. The work is on-going....

  9. Socio-psycho-historical observation on the twin. Sampling methods and case study of the atomic bomb exposed twins

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, S; Satow, Y; Ueoka, Hiroshi; Munaka, M; Kurihara, M [Hiroshima Univ. (Japan). Research Inst. for Nuclear Medicine and Biology

    1980-07-01

    The so-called ''twin control study'', mainly on the monozygotic twins one of which was A-bomb exposed and the other was non-exposed were carried out. Sampling was conducted utilizing the materials as follows: 1) The survey on casualities of A-bomb exposed families in Hiroshima which was undertaken in 1946. 2) The survey of A-bomb survivors in 1965. 3) A-bomb exposed family survey conducted between 1973 to 1975. 4) Investigations of A-bomb victims exposed in the proximal areas from the hypocenter. From the above mentioned materials 470 pairs were selected, of which 220 were exposed. Among them 172 pairs were twins of the same sex. Female and male pair were also employed. In one case they were exposed, while the others were nonexposed. Two pairs were examined under the following methods: 1) Depth interview to ascertain familial casualities with reference to the family life cycle. 2) Socio-historical research. 3) Motoaki's Jinkaku Shindan Kensa (Modified Rorschach test by H. Motoaki), and T.A.T. test. Results obtained were summarized as follows: 1) Both pairs of twins were of similar appearance and personality traits, and had a strong feeling of companionship for each other. 2) In family relationships, the persons studied were very conscious of the role expectations of elder and younger siblings in the twin pairs. 3) Through depth interviews and projective tests, A-bomb exposed pairs still showed deep psychological stresses, resulting from the A-bomb disaster. 4) Both among the exposed twins and within the nonexposed control group twin siblings had a close feeling of companionship for each other. However, nonexposed twins could not understand the psychological experience of twins who had been subjected to the atomic disaster.

  10. Analysis of potential influence factors on background urinary benzene concentration among a non-smoking, non-occupationally exposed general population sample.

    Science.gov (United States)

    Campagna, Marcello; Satta, Giannina; Campo, Laura; Flore, Valeria; Ibba, Antonio; Meloni, Michele; Tocco, Maria Giuseppina; Avataneo, Giuseppe; Flore, Costantino; Fustinoni, Silvia; Cocco, Pierluigi

    2014-01-01

    Analytical difficulties and lack of a biological exposure index and reference values have prevented using unmetabolized urinary benzene (UB) excretion as a biomarker of low-level environmental exposure. To explore what environmental factors beyond active smoking may contribute to environmental exposure to benzene, we monitored UB excretion in a non-smoking, non-occupationally exposed sample of the general population. Two spot urine samples were obtained from 86 non-smoking, non-occupationally exposed subjects, selected among a random sample of the general population of the metropolitan area of Cagliari (Sardinia, Italy), at 8:00 a.m. (UBm) and 8:00 p.m. (UBe). UB was measured by headspace solid-phase microextraction (HS-SPME) followed by gas chromatography-mass spectrometry analysis. Questionnaire information on personal and environmental exposures during the sampling day was gathered with personal interviews. Multivariate analysis of variance and multiple regression model were applied to investigate the role of such variables on the level of UB. The ninety-fifth percentile of UBe in this population was 311.5 ng/L, which is tentatively proposed as the UB guidance value for unexposed populations. UBm and urban residence were the only predictors of a significant increase in UBe excretion. Self-reported residential vehicular traffic will not account for the excess median value among urban residents; commuting time among urban residents showed a suggestive nonsignificant linear correlation with UBe, but the small sample size prevented reliable inference to be drawn. Age, environmental tobacco smoking, employment status and body mass index did not affect UB excretion. Our findings support the use of unmetabolized UB as a specific and sensitive biomarker of low-level environmental exposure to benzene.

  11. Cytogenetic monitoring of nuclear workers occupationally exposed to ionising radiation

    International Nuclear Information System (INIS)

    Griciene, B.; Slapsyte, G.; Mierauskiene, J.

    2014-01-01

    Chromosome aberration (CA) analysis using Giemsa techniques was performed in blood lymphocytes of 84 nuclear workers with cumulative doses of 1-632 mSv during employment periods of 1-25 y. The control group comprised 82 healthy male donors. An estimated CA frequency in the total radiation-exposed group was significantly higher when compared with the controls (2.27 vs. 1.76 CA/100 cells, p 0.05). However, significant increase in the total CA frequency was determined in workers with additional internal exposure (2.54 CA/100 cells, p < 0.05) and those with registered neutron doses (2.95 CA/100 cells, p < 0.01). No correlation was found between CA frequency and occupational exposure dose. Borderline significant correlation was found between duration of employment and total CA (r = 0.218, p = 0.046, Fig. 2) and chromosome-type aberration (r = 0.265, p = 0.015) frequency. (authors)

  12. Perspectives on wellness self-monitoring tools for older adults.

    Science.gov (United States)

    Huh, Jina; Le, Thai; Reeder, Blaine; Thompson, Hilaire J; Demiris, George

    2013-11-01

    Our purpose was to understand different stakeholder perceptions about the use of self-monitoring tools, specifically in the area of older adults' personal wellness. In conjunction with the advent of personal health records, tracking personal health using self-monitoring technologies shows promising patient support opportunities. While clinicians' tools for monitoring of older adults have been explored, we know little about how older adults may self-monitor their wellness and health and how their health care providers would perceive such use. We conducted three focus groups with health care providers (n=10) and four focus groups with community-dwelling older adults (n=31). Older adult participants' found the concept of self-monitoring unfamiliar and this influenced a narrowed interest in the use of wellness self-monitoring tools. On the other hand, health care provider participants showed open attitudes toward wellness monitoring tools for older adults and brainstormed about various stakeholders' use cases. The two participant groups showed diverging perceptions in terms of: perceived uses, stakeholder interests, information ownership and control, and sharing of wellness monitoring tools. Our paper provides implications and solutions for how older adults' wellness self-monitoring tools can enhance patient-health care provider interaction, patient education, and improvement in overall wellness. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  13. Perspectives on Wellness Self-Monitoring Tools for Older Adults

    Science.gov (United States)

    Huh, Jina; Le, Thai; Reeder, Blaine; Thompson, Hilaire J.; Demiris, George

    2013-01-01

    Purpose Our purpose was to understand different stakeholder perceptions about the use of self-monitoring tools, specifically in the area of older adults’ personal wellness. In conjunction with the advent of personal health records, tracking personal health using self-monitoring technologies shows promising patient support opportunities. While clinicians’ tools for monitoring of older adults have been explored, we know little about how older adults may self-monitor their wellness and health and how their health care providers would perceive such use. Methods We conducted three focus groups with health care providers (n=10) and four focus groups with community-dwelling older adults (n=31). Results Older adult participants’ found the concept of self-monitoring unfamiliar and this influenced a narrowed interest in the use of wellness self-monitoring tools. On the other hand, health care provider participants showed open attitudes towards wellness monitoring tools for older adults and brainstormed about various stakeholders’ use cases. The two participant groups showed diverging perceptions in terms of: perceived uses, stakeholder interests, information ownership and control, and sharing of wellness monitoring tools. Conclusions Our paper provides implications and solutions for how older adults’ wellness self-monitoring tools can enhance patient-health care provider interaction, patient education, and improvement in overall wellness. PMID:24041452

  14. Cluster Headache Clinical Phenotypes: Tobacco Nonexposed (Never Smoker and No Parental Secondary Smoke Exposure as a Child) versus Tobacco-Exposed: Results from the United States Cluster Headache Survey.

    Science.gov (United States)

    Rozen, Todd D

    2018-05-01

    To present results from the United States Cluster Headache Survey comparing the clinical presentation of tobacco nonexposed and tobacco-exposed cluster headache patients. Cluster headache is uniquely tied to a personal history of tobacco usage/cigarette smoking and, if the individual cluster headache sufferer did not smoke, it has been shown that their parent(s) typically did and that individual had significant secondary smoke exposure as a child. The true nontobacco exposed (no personal or secondary exposure) cluster headache sufferer has never been fully studied. The United States Cluster Headache Survey consisted of 187 multiple choice questions related to cluster headache including: patient demographics, clinical headache characteristics, family history, triggers, smoking history (personal and secondary), and headache-related disability. The survey was placed on a website from October through December 2008. One thousand one hundred thirty-four individuals completed the survey. One hundred thirty-three subjects or 12% of the surveyed population had no personal smoking/tobacco use history and no secondary smoke exposure as an infant/child, thus a nontobacco exposed population. In the nonexposed population, there were 87 males and 46 females with a gender ratio of 1.9:1. Episodic cluster headache occurred in 80% of nonexposed subjects. One thousand and one survey responders or 88% were tobacco-exposed (729 males and 272 females) with a gender ratio of 2.7:1. Eighty-three percent had a personal smoking history, while only 17% just had parents who smoked with secondary smoke exposure. Eighty-five percent of smokers had double exposure with a personal smoking history and secondary exposure as a child. Nonexposed cluster headache subjects are significantly more likely to develop cluster headache at ages 40 years and younger, while the exposed sufferers are significantly more likely to develop cluster headache at 40 years of age and older. Nonexposed patients have a

  15. Environmental monitoring report: Sandia Laboratories, 1976

    International Nuclear Information System (INIS)

    Simmons, T.N.

    1977-04-01

    Water and vegetation are monitored to determine Sandia Laboratories impact on the surrounding environment. Nonradioactive pollutants released are reported. Radioactive effluents are also reported and their person-rem contribution to the Albuquerque population is calculated. The environmental monitoring for calendar year 1976 shows that concentrations of radioactive materials in the Albuquerque area are typical of natural background for the area. An exception is a single onsite location where slightly abnormal uranium concentrations are expected. An estimated 0.044 person-rem Albuquerque area (80 km radius) population dose commitment results from calculated Sandia Laboratories releases. Over the same area 57,000 person-rem is accumulated from natural background. There were no measurable offsite radioactive effluent releases in CY 1976

  16. Behavioural changes in mice exposed to low level microwave fields

    International Nuclear Information System (INIS)

    Goiceanu, C.; Gradinaru, F.; Danulescu, R.; Balaceanu, G.; Sandu, D. D.; Avadanei, O. G.

    2001-01-01

    The aim of our study is to point out some changes in mice behaviour due possibly to exposure to low-level microwave fields. Animals spontaneous behaviour were monitored and the exploring behaviour and motor activity were assessed. Ten selected Swiss male mice were exposed to low-level microwave fields of about 1 mW/cm 2 power density for a relatively long period of time (13 weeks), comparing to their lifetime. The exposure system consists in a transverse electromagnetic (TEM) Cell. A control lot of ten Swiss male mice was used. All twenty mice were selected to be of same age and of 202 g initial body weight. Each animal was placed in his own holder. The behaviour of the animals, from both exposed and control lots, was assessed by using a battery of three behavioural tests. The test sessions were performed every two weeks. During exposure period it was recorded a progressive but moderate loss of motor activity for both exposed and controls, probably due to weight gain and aging. Concerning exploratory activity there is a significant difference between control and exposed animals. Control mice had approximately constant performances in time. On the other hand exposed mice showed a progressive decrease in time of their exploratory ability. Motor activity of exposed animals does not seem to be affected by microwave exposure, in spite of moderate loss in time of motor activity in both lots, as long as it was recorded a quite similar evolution. The difference in performances of exposed and controls concerning exploratory activity seem to emphasise an effect of long-term low-level microwave exposure. The progressive loss in time of exploratory activity of exposed mice, in contrast with controls, could be due to the interference of microwaves with central nervous activity. (authors)

  17. Monitoring of urban particulate using an electret-based passive sampler

    Energy Technology Data Exchange (ETDEWEB)

    Thorpe, A.; Hemingway, M.A.; Brown, R.C.

    1999-11-01

    Site sampling trials have been carried out in the urban environment in order to assess the usefulness of a passive sampling device, originally developed for personal monitoring of airborne dust levels in industry. The sampling element is a small disc of elect material (polymer carrying a permanent electric charge) within a metal frame weighing approximately 15 g. The sampler is designed to capture particles by electrostatic attraction, in which case the capture rate depends on their electrical mobility but is independent of the rate at which air flows past the device. Passive samplers, along with miniaturized cascade impactors, have been exposed to urban particulate for periods of up to 28 days in locations with significant different levels of airborne pollution. The cascade impactor data enabled good estimates to be made of PM{sub 10} and PMN{sub 2.5} levels, and data from the passive sampler correlated with the total dust sampled by the impactor and with both the size fractions, that with the PM{sub 10} being better. Too few data have yet been obtained for its accuracy to be established, but it is unlikely that it will approach that of pumped samplers. It has been shown to be potentially useful for multiple, simultaneous site sampling and for monitoring personal environmental exposure situations in which dispensing with a power source is particularly useful. Being small, the sampler is easy to hide or camouflage, and because it is cheap, its loss or damage is not a serious matter.

  18. Performance testing of UK personal dosimetry laboratories

    International Nuclear Information System (INIS)

    Marshall, T.O.

    1985-01-01

    The proposed Ionising Radiations Regulations will require all UK personal dosimetry laboratories that monitor classified personnel to be approved for personal dosimetry by the Health and Safety Executive. It is suggested that these approvals should be based on general and supplementary criteria published by the British Calibration Service (BCS) for laboratory approval for the provision of personal dosimetry services. These criteria specify certain qualitative requirements and also indicate the need for regular tests of performance to be carried out to ensure constancy of dosimetric standards. This report concerns the latter. The status of the BCS criteria is discussed and the need for additional documents to cover new techniques and some modifications to existing documents is indicated. A means is described by which the technical performance of laboratories, concerned with personal monitoring for external radiations, can be assessed, both initially and ongoing. The costs to establish the scheme and operate it are also estimated. (author)

  19. Fibrosis biomarkers in workers exposed to MWCNTs

    International Nuclear Information System (INIS)

    Fatkhutdinova, Liliya M.; Khaliullin, Timur O.; Vasil'yeva, Olga L.; Zalyalov, Ramil R.; Mustafin, Ilshat G.; Kisin, Elena R.; Birch, M. Eileen; Yanamala, Naveena; Shvedova, Anna A.

    2016-01-01

    Multi-walled carbon nanotubes (MWCNT) with their unique physico-chemical properties offer numerous technological advantages and are projected to drive the next generation of manufacturing growth. As MWCNT have already found utility in different industries including construction, engineering, energy production, space exploration and biomedicine, large quantities of MWCNT may reach the environment and inadvertently lead to human exposure. This necessitates the urgent assessment of their potential health effects in humans. The current study was carried out at NanotechCenter Ltd. Enterprise (Tambov, Russia) where large-scale manufacturing of MWCNT along with relatively high occupational exposure levels was reported. The goal of this small cross-sectional study was to evaluate potential biomarkers during occupational exposure to MWCNT. All air samples were collected at the workplaces from both specific areas and personal breathing zones using filter-based devices to quantitate elemental carbon and perform particle analysis by TEM. Biological fluids of nasal lavage, induced sputum and blood serum were obtained from MWCNT-exposed and non-exposed workers for assessment of inflammatory and fibrotic markers. It was found that exposure to MWCNTs caused significant increase in IL-1β, IL6, TNF-α, inflammatory cytokines and KL-6, a serological biomarker for interstitial lung disease in collected sputum samples. Moreover, the level of TGF-β1 was increased in serum obtained from young exposed workers. Overall, the results from this study revealed accumulation of inflammatory and fibrotic biomarkers in biofluids of workers manufacturing MWCNTs. Therefore, the biomarkers analyzed should be considered for the assessment of health effects of occupational exposure to MWCNT in cross-sectional epidemiological studies. - Highlights: • The effects of MWCNT exposure in humans remain unclear. • We found increased KL-6/TGF-β levels in the biofluids of MWCNT-exposed workers.

  20. Fibrosis biomarkers in workers exposed to MWCNTs

    Energy Technology Data Exchange (ETDEWEB)

    Fatkhutdinova, Liliya M., E-mail: liliya.fatkhutdinova@gmail.com [Kazan State Medical University, ul. Butlerova 49, Kazan 420012 (Russian Federation); Khaliullin, Timur O., E-mail: Khaliullin.40k@gmail.com [Kazan State Medical University, ul. Butlerova 49, Kazan 420012 (Russian Federation); Department of Physiology & Pharmacology, WVU, Morgantown, WV (United States); Vasil' yeva, Olga L., E-mail: volgaleon@gmail.com [Kazan State Medical University, ul. Butlerova 49, Kazan 420012 (Russian Federation); Zalyalov, Ramil R., E-mail: zalyalov.ramil@gmail.com [Kazan State Medical University, ul. Butlerova 49, Kazan 420012 (Russian Federation); Mustafin, Ilshat G., E-mail: ilshat64@mail.ru [Kazan State Medical University, ul. Butlerova 49, Kazan 420012 (Russian Federation); Kisin, Elena R., E-mail: edk8@cdc.gov [National Institute for Occupational Safety and Health, Morgantown, WV (United States); Birch, M. Eileen, E-mail: mib2@cdc.gov [National Institute for Occupational Safety and Health, Cincinnati, OH (United States); Yanamala, Naveena, E-mail: wqu1@cdc.gov [National Institute for Occupational Safety and Health, Morgantown, WV (United States); Shvedova, Anna A., E-mail: ats1@cdc.gov [National Institute for Occupational Safety and Health, Morgantown, WV (United States); Department of Physiology & Pharmacology, WVU, Morgantown, WV (United States)

    2016-05-15

    Multi-walled carbon nanotubes (MWCNT) with their unique physico-chemical properties offer numerous technological advantages and are projected to drive the next generation of manufacturing growth. As MWCNT have already found utility in different industries including construction, engineering, energy production, space exploration and biomedicine, large quantities of MWCNT may reach the environment and inadvertently lead to human exposure. This necessitates the urgent assessment of their potential health effects in humans. The current study was carried out at NanotechCenter Ltd. Enterprise (Tambov, Russia) where large-scale manufacturing of MWCNT along with relatively high occupational exposure levels was reported. The goal of this small cross-sectional study was to evaluate potential biomarkers during occupational exposure to MWCNT. All air samples were collected at the workplaces from both specific areas and personal breathing zones using filter-based devices to quantitate elemental carbon and perform particle analysis by TEM. Biological fluids of nasal lavage, induced sputum and blood serum were obtained from MWCNT-exposed and non-exposed workers for assessment of inflammatory and fibrotic markers. It was found that exposure to MWCNTs caused significant increase in IL-1β, IL6, TNF-α, inflammatory cytokines and KL-6, a serological biomarker for interstitial lung disease in collected sputum samples. Moreover, the level of TGF-β1 was increased in serum obtained from young exposed workers. Overall, the results from this study revealed accumulation of inflammatory and fibrotic biomarkers in biofluids of workers manufacturing MWCNTs. Therefore, the biomarkers analyzed should be considered for the assessment of health effects of occupational exposure to MWCNT in cross-sectional epidemiological studies. - Highlights: • The effects of MWCNT exposure in humans remain unclear. • We found increased KL-6/TGF-β levels in the biofluids of MWCNT-exposed workers.

  1. Radiation exposure of non-monitored hospital personnel

    International Nuclear Information System (INIS)

    Renaud, L.; Blanchette, J.; Galand, C.

    1993-02-01

    This project investigated the radiological impact of nuclear medicine patients on non-monitored personnel in hospital environments. More than 800 workers and 135 specific areas in three Quebec hospitals were surveyed daily during a six-month period with Geiger counters, TLD badges, and TLD chips. Average dose rates of up to 2.2 μSv/h were measured in some waiting areas. The radiation level of a nursing unit is a direct function of the ambulatory radioactivity carried by nuclear medicine patients. Three percent of the workers surveyed had a work-related dose in excess of 0.3 mSv/6 months (maximum 1.4 mSv/6 months). Over 88 percent were in the range between local background and 0.3 mSv/6 months. Less than 4 percent belong to groups of workers who were exposed to a level indistinguishable from background. Thus many workers surveyed in this study receive a work-related dose similar to those of medical workers monitored by Health and Welfare Canada. The average annual dose for these workers was 104 person-millisieverts. The authors recommend: better management of radioactive patients; the provision of information and education for all hospital workers having regular contact with radioactive patients; and the facilitation of the identification of nuclear medicine patients within the hospital environment. (28 tabs., 23 figs.)

  2. Peculiarities of gastrointestinal tract diseases course in the persons exposed to ionizing radiation

    International Nuclear Information System (INIS)

    Pasyijeshvyilyi, L.M.

    1994-01-01

    The study involved 145 men aged 21 - 49 years, who were exposed to radiation in the dose of 9.3 ± 1.6 rem at different terms of their stay in 30-km zone during 49 ± 5.4 days. In the study group, chronic gastroduodenitis was diagnosed in 56 patients, chronic cholecystitis - in 47 patients, chronic pancreatitis - in 42 patients. In spite of the difference of nosologic forms, main clinical features of the disease were noted to be the changes of vegetative nervous system and psycho emotional changes

  3. The smart house for older persons and persons with physical disabilities: structure, technology arrangements, and perspectives.

    Science.gov (United States)

    Stefanov, Dimitar H; Bien, Zeungnam; Bang, Won-Chul

    2004-06-01

    Smart houses are considered a good alternative for the independent life of older persons and persons with disabilities. Numerous intelligent devices, embedded into the home environment, can provide the resident with both movement assistance and 24-h health monitoring. Modern home-installed systems tend to be not only physically versatile in functionality but also emotionally human-friendly, i.e., they may be able to perform their functions without disturbing the user and without causing him/her any pain, inconvenience, or movement restriction, instead possibly providing him/her with comfort and pleasure. Through an extensive survey, this paper analyzes the building blocks of smart houses, with particular attention paid to the health monitoring subsystem as an important component, by addressing the basic requirements of various sensors implemented from both research and clinical perspectives. The paper will then discuss some important issues of the future development of an intelligent residential space with a human-friendly health monitoring functional system.

  4. Wireless monitoring system for personal dose

    International Nuclear Information System (INIS)

    Kobayashi, Hironobu; Kawamura, Takeshi; Inoue, Takayuki

    2000-01-01

    Fuji Electric has developed a system for the higher radiation controlled area in nuclear power plants, in which exposure dose data measured on the wearer's chest, hands, and legs are transferred by wireless to the data control equipment so that the exposure dose can be controlled in real time. The system using a specified low-power radio wave causes no interference to the other types of dosimeters. The data control equipment automatically saves data received from the dosimeters and also has functions of calibration of dosimeters and maintenance of the wireless system. This paper describes the wireless monitoring system that consists of chest and parts dosimeters and data control equipment. (author)

  5. Personal monitoring for external sources of beta and low energy photon radiations

    Energy Technology Data Exchange (ETDEWEB)

    Christensen, P.; Herbaut, Y.; Marshall, T.O.

    1987-01-01

    In general, the dosemeters currently used for personal monitoring of beta and low energy photon doses suffer from an energy threshold problem because the detector and/or filter is too thick. Furthermore, current non-tissue-equivalent dosemeters, e.g. film dosemeters, are not provided with the filters needed to evaluate beta ray and low energy photon doses separately. To improve the present state of film dosemeters the thickness of the film wrapping paper should be reduced significantly and the badge should be provided with a number of pairs of thin filters. The dose evaluation from such a dosemeter is, however, complex and inaccurate and it seems unlikely that the required improvement is achievable at a reasonable cost. Improvement of tissue-equivalent dosemeters is possible by further development of multi-element dosemeters and thin detectors. The multi-element method has the advantage of using existing detectors, however the dose estimation is encumbered with high random error and the dosemeter design may become prohibitively expensive. The use of thin tissue-equivalent detectors implies a very simple badge design and an inherently accurate and uncomplicated dose evaluation. The development of adequate, thin, tissue-equivalent detectors suited for automated processing should therefore be encouraged.

  6. Personal monitoring for external sources of beta and low energy photon radiations

    International Nuclear Information System (INIS)

    Christensen, P.; Herbaut, Y.; Marshall, T.O.

    1987-01-01

    In general, the dosemeters currently used for personal monitoring of beta and low energy photon doses suffer from an energy threshold problem because the detector and/or filter is too thick. Furthermore, current non-tissue-equivalent dosemeters, e.g. film dosemeters, are not provided with the filters needed to evaluate beta ray and low energy photon doses separately. To improve the present state of film dosemeters the thickness of the film wrapping paper should be reduced significantly and the badge should be provided with a number of pairs of thin filters. The dose evaluation from such a dosemeter is, however, complex and inaccurate and it seems unlikely that the required improvement is achievable at a reasonable cost. Improvement of tissue-equivalent dosemeters is possible by further development of multi-element dosemeters and thin detectors. The multi-element method has the advantage of using existing detectors, however the dose estimation is encumbered with high random error and the dosemeter design may become prohibitively expensive. The use of thin tissue-equivalent detectors implies a very simple badge design and an inherently accurate and uncomplicated dose evaluation. The development of adequate, thin, tissue-equivalent detectors suited for automated processing should therefore be encouraged. (author)

  7. The use of a personal digital assistant for dietary self-monitoring does not improve the validity of self-reports of energy intake.

    Science.gov (United States)

    Yon, Bethany Ann; Johnson, Rachel K; Harvey-Berino, Jean; Gold, Beth Casey

    2006-08-01

    Underreporting of energy intake is a pervasive problem and resistant to improvement, especially among people with overweight and obesity. The goal of this study was to investigate whether the use of a personal digital assistant (PDA) for dietary self-monitoring would reduce underreporting prevalence and improve the validity of self-reported energy intake. Adults with overweight and obesity (n=61, 92% women, mean age 48.2 years, mean body mass index 32.3) were provided with a PalmZire 21 (Palm, Inc, Sunnyvale, CA) loaded with Calorie King's Diet Diary software (version 3.2.2, 2002, Family Health Network, Costa Mesa, CA). Subjects participated in a 24-week in-person behavioral weight control program and were asked to self-monitor their diet and exercise habits using the PDA. Basal metabolic rate and physical activity level were estimated at baseline. Energy intake from 7-day electronic food records were collected within the first month of the weight-control program. As subjects were actively losing weight, Bandini's adjustments were used to correct self-reported energy intake for weight loss. In this group, where 41% of the subjects were categorized as low-energy reporters, the use of a PDA did not improve validity of energy reporting when compared to what is reported in the literature.

  8. Wireless patient monitoring system for a moving-actuator type artificial heart.

    Science.gov (United States)

    Nam, K W; Chung, J; Choi, S W; Sun, K; Min, B G

    2006-10-01

    In this study, we developed a wireless monitoring system for outpatients equipped with a moving-actuator type pulsatile bi-ventricular assist device, AnyHeart. The developed monitoring system consists of two parts; a Bluetooth-based short-distance self-monitoring system that can monitor and control the operating status of a VAD using a Bluetooth-embedded personal digital assistant or a personal computer within a distance of 10 meters, and a cellular network-based remote monitoring system that can continuously monitor and control the operating status of AnyHeart at any location. Results of in vitro experiments demonstrate the developed system's ability to monitor the operational status of an implanted AnyHeart.

  9. Fracture risk by HIV infection status in perinatally HIV-exposed children.

    Science.gov (United States)

    Siberry, George K; Li, Hong; Jacobson, Denise

    2012-03-01

    The objective of this study was to examine the incidence of fractures in HIV-infected children and comparable HIV-exposed, uninfected (HEU) children in a multicenter, prospective cohort study (PACTG 219/219C) in the United States. The main outcome was first fracture during the risk period. Nine fractures occurred in 7 of 1326 HIV-infected and 2 of 649 HEU children, corresponding to incidence rates of 1.2 per 1000 person-years and 1.1 per 1000 person-years, respectively. The incidence rate ratio was 1.1 (95% CI 0.2, 5.5). There was no evidence of a substantially increased risk of fracture in HIV-infected compared to HEU children.

  10. Incorporation of personal computers in a research reactor instrumentation system for data monitoring and analysis

    International Nuclear Information System (INIS)

    Leopando, L.S.

    1998-01-01

    The research contract was implemented by obtaining off-the shelf personal computer hardware and data acquisition cards, designing the interconnection with the instrumentation system, writing and debugging the software, and the assembling and testing the set-up. The hardware was designed to allow all variables monitored by the instrumentation system to be accessible to the computers, without requiring any major modification of the instrumentation system and without compromising reactor safety in any way. The computer hardware addition was also designed to have no effect on any existing function of the instrumentation system. The software was designed to implement only graphical display and automated logging of reactor variables. Additional functionality could be easily added in the future with software revision because all the reactor variables are already available in the computer. It would even be possible to ''close the loop'' and control the reactor through software. It was found that most of the effort in an undertaking of this sort will be in software development, but the job can be done even by non-computer specialized reactor people working with programming languages they are already familiar with. It was also found that the continuing rapid advance of personal computer technology makes it essential that such a project be undertaken with inevitability of future hardware upgrading in mind. The hardware techniques and the software developed may find applicability in other research reactors, especially those with a generic analog research reactor TRIGA console. (author)

  11. Space Station personal hygiene study

    Science.gov (United States)

    Prejean, Stephen E.; Booher, Cletis R.

    1986-01-01

    A personal hygiene system is currently under development for Space Station application that will provide capabilities equivalent to those found on earth. This paper addresses the study approach for specifying both primary and contingency personal hygiene systems and provisions for specified growth. Topics covered are system definition and subsystem descriptions. Subsystem interfaces are explored to determine which concurrent NASA study efforts must be monitored during future design phases to stay up-to-date on critical Space Station parameters. A design concept for a three (3) compartment personal hygiene facility is included as a baseline for planned test and verification activities.

  12. A survey of an air monitoring program

    International Nuclear Information System (INIS)

    Lee, M.B.

    1997-01-01

    The objective of this report is to compare personal air sampling data to stationary air sampling data and to bioassay data that was taken during the decontamination and decommissioning of sixty-one plutonium glove boxes at Argonne National Laboratory (ANL) in 1995. An air monitoring program administered at Argonne National Laboratory was assessed by comparing personal air sampler (PAS) data, stationary air sampler (SAS) data, and bioassay data. The study revealed that the PAS and SAS techniques were equivalent when averaged over all employees and all workdays, but the standard deviation was large. Also, large deviations were observed in individual samples. The correlation between individual PAS results and bioassay results was low. Personal air samplers and bioassay monitoring played complementary roles in assessing the workplace and estimating intakes. The PAS technique is adequate for detection and evaluation of contaminated atmospheres, whereas bioassay monitoring is better for determining individual intakes

  13. Radiation risk factors in incidence anortality among exposed individuals of East Kazakhstand m

    Directory of Open Access Journals (Sweden)

    Kazbek Apsalikov

    2014-01-01

    Full Text Available Introduction: Lengthy clinical and epidemiological studies at the Research Institute of Radiation Medicine and Ecology have discovered basic patterns of long-term effects from ionizing radiation in population groups exposed to radiation risk. Methodology for calculating injury from radiation risk factors has been developed and implemented to minimize the effects of the Semipalatinsk nuclear test site (SNTS. Material and methods: We analyzed materials from the database of the Scientific Medical Register that were exposed to radiation as a result of SNTS. We analyzed both male and female populations of the Abay, Beskaragai and Zhanasemei, Kokpekti (control areas of East-Kazakhstan region (EKR from 2008-2012. These populations were split into three groups allocated by the generation. The first group represented persons born from the period of 01/01/1930 -08/01/1949 and their children born from the period of 10/09/1949-12/31/1962. The second group were persons born after 01/01/1963. The third group served as the control and were persons who immigrated to these areas after 1990. Results: There was an increased incidence of cancer (21.5%, p < 0.000734, cardiovascular diseases (10.2%; respiratory problems (9.6%, gastrointestinal issues (9.1%, p < 0.00371-0.00679 in the first group. The effect of the radiation dose has not been fully stuided among the subjects in the second group.The major causes of excess mortality in the first group were neoplams (30.6%, hypertension (23.8%, and myocardial infarction (22.6%. The effects of radiation influenced mortality in the second group were 2-2.5 times lower than the first group.Conclusion: There is a correlation between the size of the radiation dose, the risk profile, and age at the moment of radiation exposure with trends of morbidity and mortality in the radiation exposed areas.

  14. Importance of the personal endotoxin cloud in school-age children with asthma.

    Science.gov (United States)

    Rabinovitch, Nathan; Liu, Andrew H; Zhang, Lening; Rodes, Charles E; Foarde, Karin; Dutton, Steven J; Murphy, James R; Gelfand, Erwin W

    2005-11-01

    A number of studies have observed associations between the amount of endotoxin in urban dust and chronic asthma severity, but a direct relationship between personal exposure to household endotoxin and acute asthma worsening has not yet been defined. We sought to investigate the relationship between day-to-day changes in personal endotoxin exposure and asthma severity. In the winter and spring of 1999 through 2000, endotoxin exposures were monitored in asthmatic schoolchildren by using portable, as opposed to stationary, monitors designed to measure inhalable and respirable particulate matter less than or equal to 2.5 and 10 microm in diameter. Children were followed with daily measurements of FEV(1) and asthma symptoms. Over a 24-hour period, median daily personal endotoxin exposures ranged from 0.08 EU/m(3) (measured at a particulate matter size range Personal exposures were significantly (P personal activities might be better correlated with disease severity. Increases in personal endotoxin exposures were associated with decreased FEV(1) values and increased symptoms. These findings demonstrate the importance of using personal monitoring to both measure and correlate endotoxin exposure with asthma severity.

  15. Controlled Sharing of Personal Information in Android

    OpenAIRE

    Bø, Solvår; Pedersen, Stian; Nyre, Åsmund Ahlmann; Bernsmed, Karin

    2011-01-01

    Smartphones with third-party applications have become very popular. Recently, they have received attention for quietly monitoring and transferring personal information without the users’ knowledge. The objective of this work is to help users to protect their privacy by increasing their consciousness on how personal information is collected and distributed. We propose a design that provides a higher degree of control by allowing users to set preferences that determine what personal information...

  16. Personality profiles and psychopathology among students exposed to dating violence at theObafemi AwolowoUniversity, Ile-Ife.

    Science.gov (United States)

    Boladale, Mapayi; Yetunde, Oladimeji; Adesanmi, Akinsulore; Olutayo, Aloba; Olanrewaju, Ibigbami

    2015-01-01

    Dating violence is a complex phenomenon, and researchers continue to examine a wide range of precursors and contributing factors. Evidence indicates that violent intimate partners may be more likely to have personality disorders and dependency and attachment problems compared with non-violent ones. The aim of the present study is to evaluate the interaction between the personality profiles, pattern of psychopathology, and dating violence among university students in Obafemi Awolowo University, Ile-Ife. The study utilized a cross-sectional survey design with a total of 400 students selected using a multistage sampling technique. They completed the Sociodemographic Data Schedule, the Conflict Tactic Scale (CTS), Eysenck Personality Questionnaire (EPQ), and the General Health Questionnaire (GHQ). Univariate analysis was used to determine the prevalence of dating violence, psychopathology, and personality traits, and these were expressed in percentages. Association at bivariate level was assessed using chi-square and at multivariate level using logistic regression and correlations as was appropriate depending on the type of variable. The age of the respondents ranged between 18 and 35 years (M = 21.44, SD = 2.99). The prevalence of dating violence in the previous 12 months was 34%, and the prevalence of psychopathology was 15%. In the logistic regression model constructed, it was found that the significant predictors of dating violence were the psychoticism and neuroticism personality traits, which were also found to be positive correlates of psychopathology. The magnitude of dating violence found in this study is comparable with those found in other countries of the world. This study found an association between dating violence and personality in the study population and also between certain personality traits and psychopathology. The personality profiles of students could affect their interpersonal relationships greatly, and this fact must feature in dating violence

  17. Investigation of self-indicating radiation personal dosimeter

    International Nuclear Information System (INIS)

    Xia Wen; Ye Honsheng; Lin Min; Xu Lijun; Chen Kesheng; Chen Yizhen

    2014-01-01

    A self-indicating radiation personal dosimeter was investigated using radiation sensitive material diacetylene monomer PCDA, which was a component of the polymerization system. The substrate material, solvent, sensitive material, solution temperature, thickness of film and the preparation method were studied. The dosimeter colour changes from white to blue when exposed 0.1-2.5 Gy, and the linearly dependent coefficient of the exposure response is 0.9998, the stability of absorbency in two weeks after exposure is testified well. It can be used as self-indicating radiation alert personal dosimeter. (authors)

  18. Inactivation of viruses in bubbling processes utilized for personal bioaerosol monitoring.

    Science.gov (United States)

    Agranovski, I E; Safatov, A S; Borodulin, A I; Pyankov, O V; Petrishchenko, V A; Sergeev, A N; Agafonov, A P; Ignatiev, G M; Sergeev, A A; Agranovski, V

    2004-12-01

    A new personal bioaerosol sampler has recently been developed and evaluated for sampling of viable airborne bacteria and fungi under controlled laboratory conditions and in the field. The operational principle of the device is based on the passage of air through porous medium immersed in liquid. This process leads to the formation of bubbles within the filter as the carrier gas passes through and thus provides effective mechanisms for aerosol removal. As demonstrated in previous studies, the culturability of sampled bacterium and fungi remained high for the entire 8-h sampling period. The present study is the first step of the evaluation of the new sampler for monitoring of viable airborne viruses. It focuses on the investigation of the inactivation rate of viruses in the bubbling process during 4 h of continuous operation. Four microbes were used in this study, influenza, measles, mumps, and vaccinia viruses. It was found that the use of distilled water as the collection fluid was associated with a relatively high decay rate. A significant improvement was achieved by utilizing virus maintenance fluid prepared by using Hank's solution with appropriate additives. The survival rates of the influenza, measles, and mumps viruses were increased by 1.4 log, 0.83 log, and 0.82 log, respectively, after the first hour of operation compared to bubbling through the sterile water. The same trend was observed throughout the entire 4-h experiment. There was no significant difference observed only for the robust vaccinia virus.

  19. Clinical, cytogenetic and toxicological studies in rural workers exposed to pesticides in Botucatu, São Paulo, Brazil

    Directory of Open Access Journals (Sweden)

    Salete Marcia Bréga

    1998-01-01

    Full Text Available Pesticides can cause gene mutations and chromosomal aberrations in exposed individuals. We have investigated 24 workers exposed to pesticides. Clinical examinations and cytogenetic and toxicological tests were performed. Ten non-exposed individuals were used as controls. Toxicological dosages of copper, zinc and manganese (metals found in some pesticides, hepatic enzyme dosage (GOT, GPT, AR and acetylcholinesterase activity were performed in 16 workers and 8 controls. In the exposed workers, the most relevant clinical symptoms were poor digestion with fullness sensation after meals, irritated eyes, headache and fasciculations. The exposed group showed significantly lower manganese dosage and acetylcholinesterase activity, and significantly higher levels of alkaline phosphatase. Cytogenetic studies showed significantly higher chromosomal aberrations in the exposed group compared to the control group. Although the workers used protection against the pesticide's fog, the results revealed that the workers were contaminated with the pesticides. Therefore, the cytogenetic, toxicological studies with clinical examination are necessary for monitoring workers who are exposed to pesticides in any situation.

  20. Individual monitoring in high-energy stray radiation fields

    International Nuclear Information System (INIS)

    Hoefert, M.; Stevenson, G.R.

    1995-01-01

    Due to the lack of passive or active devices that could be considered as personal dosemeters in high-energy stray fields one can at present only perform individual monitoring around high energy accelerators. Of all detectors currently available it is shown that the NTA film is the most suitable method for individually monitoring the neutron exposure of more than 3000 persons regularly, reliably, and cost effectively like at CERN. (author)

  1. Individual differences and repeatability in vocal production: stress-induced calling exposes a songbird's personality

    Science.gov (United States)

    Guillette, Lauren M.; Sturdy, Christopher B.

    2011-11-01

    Recent research in songbirds has demonstrated that male singing behavior varies systematically with personality traits such as exploration and risk taking. Here we examine whether the production of bird calls, in addition to bird songs, is repeatable and related to exploratory behavior, using the black-capped chickadee ( Poecile atricapillus) as a model. We assessed the exploratory behavior of individual birds in a novel environment task. We then recorded the vocalizations and accompanying motor behavior of both male and female chickadees, over the course of several days, in two different contexts: a control condition with no playback and a stressful condition where chick-a-dee mobbing calls were played to individual birds. We found that several vocalizations and behaviors were repeatable within both a control and a stressful context, and across contexts. While there was no relationship between vocal output and exploratory behavior in the control context, production of alarm and chick-a-dee calls in the stressful condition was positively associated with exploratory behavior. These findings are important because they show that bird calls, in addition to bird song, are an aspect of personality, in that calls are consistent both within and across contexts, and covary with other personality measures (exploration).

  2. Determination of the absorbed dose rate to a person exposed to a spent source of {sup 60}Co for radiotherapy; Determinacion de la rapidez de dosis absorbida a una persona expuesta a una fuente gastada de {sup 60}Co para radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Garcia M, T.; Angeles C, A.; Benitez, J. A.; Ruiz C, M. A., E-mail: teodoro.garcia@inin.gob.mx [ININ, Departamento de Proteccion Radiologica, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2016-09-15

    In this work the analysis of absorbed dose rate to a person in made due to the exposure to a spent source of {sup 60}Co of radiotherapy, which has been removed from its shielding clandestinely to sell the shielding as scrap. During the removal of the source of their shielding the people were necessarily exposed to the field of gamma radiation. The activity of the source is considered to be 2595 Ci at the exposure time and to determine the rate of absorbed dose to different organs and the velocity of effective absorbed dose to which the person (s) who manipulated the source of {sup 60}Co were considered three plausible scenarios of manipulation of the source , through modeling with MCNP5. For the execution of the scenarios and the determination of the absorbed doses, two different phantoms are considered. The results obtained for each scenario show that the dose rates to which the people who manipulated the source without the shielding were exposed are extremely high, and in short time the lethal dose is reached. (Author)

  3. OSHA medical and workplace surveillance requirements and NIOSH recommendations (for employees exposed to toxic substances and other work hazards)

    Science.gov (United States)

    Cooper, L. P.

    1983-01-01

    Both OSHA medical and work place surveillance requirements and NIOSH recommendations were prepared as a desk reference to help occupational health professionals to perform their duties. The medical surveillance information focuses on frequency of physical examinations, specific problems that may arise as a result of exposure (e.g., decreased immunocompetence, weight loss, ets.), conditions that intensify the harmful effects of exposure (e.g., medication an exposed employee may be taking, cigarette smoking, etc.), the areas that should be scrutinized in medical and work histories and during the physical exam, and specific clinical tests that should be conducted. Recordkeeping requirements are also specified. The workplace surveillance information consists of monitoring requirements, personal protective equipment requirements, and recordkeeping requirements. Such details as the sampling devices that should be used, the type of respirators that should be worn, and the frequency of inspections are included. This document does not specify the training, labeling and posting, and safe work practice requirements and recommendations due to space considerations.

  4. Multi-controller based 29 channel whole body portal monitor

    International Nuclear Information System (INIS)

    Dheeraj Reddy, J.; Narender Reddy, J.

    2004-01-01

    Portal Monitors are an essential part of personnel monitoring programme in any Nuclear Power Plant or Radiochemical/Reprocessing Plant. Compared to conventional Portal Monitors, whole-body Portals are preferred, for effective monitoring of entire body of the person being monitored for radioactive contamination. This is achieved by effectively distributing a large number of detectors on front/back of the person being monitored. The entry and exit for such Portals is usually side ways. The electronic system, designed essentially consists of powerful compact electronic circuits, comprising of three micro-controllers, a host of (32) 12C serial counters, other serial ADCs, DACs etc., apart from pulse processing, HV and LV circuits. Built-in embedded code has powerful fault diagnostics routines to show up failures in detector / detector electronics, HV, LV and other circuits apart from indicating contamination status, through visual and aural indications such as MIMIC, visual LCD display and individual channel counts etc. The Portal structural design consists of four individual SS members integrated, lead shielding assemblies (inside), on hinged support frames facilitate ease of assembling and dismantling of the structure. The detector arrangement is so arranged to have optimal uniform spread out, so as to record contamination of the whole body of the person being monitored. (author)

  5. Harmonisation (legal, dosimetric, quality aspects) of individual monitoring, and integration of monitoring for external and internal exposures (EURADOS working group)

    International Nuclear Information System (INIS)

    Lopez, M.A.; Currivan, L.; Falk, R.; Olko, P.; Wernli, C.; Castellani, C.M.; Dijk, J.W.E. van

    2003-01-01

    The EURADOS Working Group II on 'Harmonisation of individual monitoring' consists of experts from almost all EU Member States and Newly Associated States (NAS), involved in tasks related to the assessment of doses for internal and external radiation. The final objective is to achieve harmonisation in individual monitoring for occupational exposures. Sub-group 2 activities are focused on investigating how the results from personal dosemeters for external radiation and workplace monitoring and from monitoring for internal exposure can be combined into a complete and consistent system of individual monitoring. Three questionnaires were prepared, covering Individual monitoring of external radiation (Questionnaire 1), 'Internal exposure' (Questionnaire 2) and 'Natural sources of radiation at workplace' (Questionnaire 3). With the agreement of a 'contact-person' selected in each country, the distribution of the three EURADOS 2002 questionnaires was carried out by e-mail among the dosimetry facilities of 28 European countries. The preliminary results of these actions are presented here. (author)

  6. Guide on medical management of persons exposed in radiation accidents

    International Nuclear Information System (INIS)

    1990-01-01

    The present guide has been prepared in order to provide guidance to medical and para-medical personnel regarding medical management of the different types of radiation accidents. It discusses briefly the physical aspects and biological effect of radiation, for the benefit of those who have not specialised in radiation medicine. The diagnosis, medical management and follow-up of persons involved in different types of radiation accidents are also dealt with. The implementation of the procedures described calls for organisation of appropriate facilities and provision of requisite equipment as well as education and training of the staff. It is emphasised that major radiation accidents are rare events and the multi-disciplinary nature of the response required to deal with them calls for proper planning and continuous liaison among plant management, radiation protection personnel, first-aid assistants and medical and paramedical staff. The organisation and conduct of emergency drills may help in maintaining preparedness of the medical facilities for efficient management of radiation casualities. (original). 64 refs., tabs., figs

  7. Multimodal Neural Network for Overhead Person Re-identification

    DEFF Research Database (Denmark)

    Lejbølle, Aske Rasch; Nasrollahi, Kamal; Krogh, Benjamin

    2017-01-01

    Person re-identification is a topic which has potential to be used for applications within forensics, flow analysis and queue monitoring. It is the process of matching persons across two or more camera views, most often by extracting colour and texture based hand-crafted features, to identify...

  8. Application of the Alkaline comet assay in bio monitoring of medical personnel occupationally exposed to ionizing radiation

    International Nuclear Information System (INIS)

    Kopjar, N.; Graj-Vrhovac, V.

    2002-01-01

    Ionising radiation is a ubiquitous environmental physical agent whose DNA damaging effects are fairly well established. The effects of low-level exposure to ionizing radiation are of concern to large number of people, including workers receiving radiation exposure on the job. Medical radiation workers are employees of hospitals, clinics and private offices where radiation is used in the process of delivering health care to humans. These workers can be categorised into two groups exposed employees who receive at least a minimum detectable exposure during a one-year period, and potentially exposed employees who work in the vicinity of radiation but whose exposures are below detectable limits. The exposure of patients and workers to radiation in medicine is a direct consequence of the use of radiation to improve the health of the individuals. Trends in radiation exposure of both patients and workers are effected not only by developments in radiation protection, but also by dose in the practice of medicine. It is very important to estimate absorbed doses from individuals occupationally exposed to ionizing radiation for carrying out radioprotection procedures and restrict the hazards to human health. The extent of health hazards is difficult to assess. Therefore, development of procedures that can be used to precisely identify health hazards in the exposed populations is a most significant approach towards establishing effective programs for disease prevention

  9. Genotoxic monitoring of nurses handling cytotoxic drugs

    Directory of Open Access Journals (Sweden)

    Anna Tompa

    2016-01-01

    Full Text Available Objective: Several biomarkers may be used to detect harmful exposure and individual susceptibility to cancer. Monitoring of biomarkers related to exposure may have a significant effect on early detection of cell transformation, thereby aiding the primary prevention of various chronic and malignant diseases. Nurses who handle cytotoxic drugs are exposed to carcinogenic agents, which have the potential to interrupt the cell cycle and to induce chromosomal aberrations. The presence of high chromosomal aberrations indicates the need for intervention even when exposure to these carcinogens is low. Methods: Nationally representative samples of 552 nurses were investigated by a follow-up monitoring system. The measured biomarkers were clinical laboratory routine tests, completed with genotoxicological (chromosome aberrations [CAs] and sister chromatid exchanges [SCEs] and immunotoxicological monitoring (ratio of lymphocyte subpopulations and lymphocyte activation markers measured on peripheral blood lymphocytes. Results were compared to the data of 140 healthy, age-matched controls. Results: In nurses exposed to cytostatics, we observed a significantly increased frequency of CAs and SCEs compared with those in the controls. Cytostatic drug exposure also manifested itself in an increased frequency of helper T lymphocytes. Genotoxicological and immunotoxicological changes, as well as negative health effects (i.e., iron deficiency, anemia, and thyroid diseases, increased among cytostatic exposed subjects. Conclusions: These results raised concerns about the protection of nursing staff from chemical carcinogens in the working environment.

  10. Confidentiality and personal integrity.

    Science.gov (United States)

    Edgar, A

    1994-06-01

    This paper uses the social theory of Erving Goffman in order to argue that confidentiality should be understood in relation to the mundane social skills by which individuals present and respect specific self-images of themselves and others during social interaction. The breaching of confidentiality is analysed in terms of one person's capacity to embarrass another, and so to expose that person as incompetent. Respecting confidentiality may at once serve to protect the vulnerable from an unjust society, and yet also protect the guilty from just accusation. Ethical reasoning about confidentiality must therefore recognize the dangers of prejudice and violence inherent in decisions to breach or to respect confidentiality. Case studies are used to illustrate the efficacy of this account, culminating with analyses of three examples from the UKCC document Confidentiality.

  11. Preliminary study of internal monitoring of the occupational exposed individuals to the 18FDG at the C RCN-Ne, Recipe, Pernambuco, Brazil

    International Nuclear Information System (INIS)

    Oliveira, Cassio M.; Lacerda, Isabelle V.B.; Lima, Fabiana F.; Oliveira, Mercia L.; Silva, Tania V. da; Alonso, Thessa C.; Silva, Teogenes A. da

    2011-01-01

    This work aims to develop and establish a methodology for in vivo internal monitoring at individuals occupationally exposed (IOE) to F-18 in form of F-18DG at the DIPRA/CRCN-NE. The detection system used was the NaI(Tl) 3' x 3', coupled with the software Genie 2000. The measurements performed with the brain phantom were used to obtain the Calibration Factor. The bioassay data interpretation was performed through software AIDE, using the F-18DG biokinetic model available in ICRP 53 publication. The MDED obtained was compared to the value of the recording level, 1 mSv, recommended by IAEA in order to validate the technique. During two days of F-18DG productions, there were performed in vivo measurements of the IOE at DIPRA/CRCN-NE. The methodology developed demonstrated sufficient sensitivity for detect MDED of 76 n Sv. The results of the in vivo measurements demonstrated that all IOE from CRCN/NE obtained doses below MDED. (author)

  12. Materiomics for Oral Disease Diagnostics and Personal Health Monitoring: Designer Biomaterials for the Next Generation Biomarkers

    Science.gov (United States)

    Zhang, Wenjun; Wang, Ming L.; Khalili, Sammy

    2016-01-01

    Abstract We live in exciting times for a new generation of biomarkers being enabled by advances in the design and use of biomaterials for medical and clinical applications, from nano- to macro-materials, and protein to tissue. Key challenges arise, however, due to both scientific complexity and compatibility of the interface of biology and engineered materials. The linking of mechanisms across scales by using a materials science approach to provide structure–process–property relations characterizes the emerging field of ‘materiomics,’ which offers enormous promise to provide the hitherto missing tools for biomaterial development for clinical diagnostics and the next generation biomarker applications towards personal health monitoring. Put in other words, the emerging field of materiomics represents an essentially systematic approach to the investigation of biological material systems, integrating natural functions and processes with traditional materials science perspectives. Here we outline how materiomics provides a game-changing technology platform for disruptive innovation in biomaterial science to enable the design of tailored and functional biomaterials—particularly, the design and screening of DNA aptamers for targeting biomarkers related to oral diseases and oral health monitoring. Rigorous and complementary computational modeling and experimental techniques will provide an efficient means to develop new clinical technologies in silico, greatly accelerating the translation of materiomics-driven oral health diagnostics from concept to practice in the clinic. PMID:26760957

  13. USB-based radiation monitor

    International Nuclear Information System (INIS)

    Drndarevic, V.; Jevtic, N.; Djuric, R.

    2006-01-01

    The Universal Serial Bus has become a dominant interface for the connection of standard peripheral devices to a personal computer. This paper analyzes the possibilities of USB bus applications in the field of measurement and environmental monitoring. As a result, a gamma radiation monitor consisting of an USB-based universal peripheral device and a gamma probe with a GM counter, has been designed. For the interfacing monitor with the powerful and easy to use LabVIEW software package, an instrument driver as a set of virtual instruments has been developed. The proposed monitor is a flexible instrument which can be used for laboratory measurements, as an environmental radiation monitor or for training purposes. Connected to the laptop computer, the monitor becomes a portable instrument suitable for field measurements. Basic measurements and functionality properties of the radiation monitor are presented here

  14. Voices of nuclear power monitors in fiscal 1982

    International Nuclear Information System (INIS)

    1984-01-01

    The system of nuclear power monitors was set up to hear candid opinions, etc. from general people on nuclear power development and utilization, and reflect them to nuclear power administration. As the monitors, 416 persons were selected across the country. The results in fiscal 1982 are described. (1) Questionnaire survey: Of the 416, 314 persons answered the questionnaire conducted in March, 1983, on future energy, nuclear power development, nuclear power safety administration, and nuclear power P.R. activities. (2) Occasional voices of monitors: Of the total 74 opinions, etc. from the monitors in fiscal 1982, 31 concerned the nuclear power P.R. activities, followed by 16 on nuclear power development and utilization, and 12 on nuclear power administration. (Mori, K.)

  15. Development of a Personal Integrated Environmental Monitoring System

    Directory of Open Access Journals (Sweden)

    Man Sing Wong

    2014-11-01

    Full Text Available Environmental pollution in the urban areas of Hong Kong has become a serious public issue but most urban inhabitants have no means of judging their own living environment in terms of dangerous threshold and overall livability. Currently there exist many low-cost sensors such as ultra-violet, temperature and air quality sensors that provide reasonably accurate data quality. In this paper, the development and evaluation of Integrated Environmental Monitoring System (IEMS are illustrated. This system consists of three components: (i position determination and sensor data collection for real-time geospatial-based environmental monitoring; (ii on-site data communication and visualization with the aid of an Android-based application; and (iii data analysis on a web server. This system has shown to be working well during field tests in a bus journey and a construction site. It provides an effective service platform for collecting environmental data in near real-time, and raises the public awareness of environmental quality in micro-environments.

  16. Rorschach Assessment of Two Distinctive Personality States of a Person With Dissociative Identity Disorder.

    Science.gov (United States)

    Hartmann, Ellen; Benum, Kirsten

    2017-12-13

    This case study used test data from a patient with Dissociative Identity Disorder (DID; American Psychiatric Association, 2013 ) to illustrate how two main personality states of the patient ("Ann" and "Ben") seemed to function. The Rorschach Performance Assessment System (R-PAS; Meyer, Viglione, Mihura, Erard, & Erdberg, 2011 ) and the Inventory of Interpersonal Problems-Circumplex (IIP-64; Horowitz, Alden, Wiggins, & Pincus, 2000 ), administered to Ann and Ben in separate settings, exposed two diverse R-PAS and IIP-64 profiles. Ann's R-PAS profile suggested an intellectualized style of information processing with few indications of psychological problems. Ben's profile indicated severe perceptual, cognitive, and interpersonal difficulties combined with suspicion and anxiety. Ann's IIP-64 profile suggested minor interpersonal problems, whereas Ben's indicated serious relational difficulties. The findings were discussed in relation to the theory of trauma-related structural dissociation of the personality (van der Hart, Nijenhuis, & Steele, 2006 ), which implies an enduring split in the organization of the personality with more or less separate entities with their own sense of self, perception of the world, and ways of organizing emotional, cognitive, and social functions. The DID personality structure is seen as a defense strategy and as a pathway in the personality development producing serious psychological pain and symptoms.

  17. Humoral immunity in tuberculin skin test anergy and its role in high-risk persons exposed to active tuberculosis.

    Science.gov (United States)

    Encinales, Liliana; Zuñiga, Joaquin; Granados-Montiel, Julio; Yunis, Maria; Granados, Julio; Almeciga, Ingrid; Clavijo, Olga; Awad, Carlos; Collazos, Vilma; Vargas-Rojas, María Inés; Bañales-Mendez, José Luis; Vazquez-Castañeda, Lilia; Stern, Joel N; Romero, Viviana; Fridkis-Hareli, Masha; Frindkis-Hareli, Masha; Terreros, Daniel; Fernandez-Viña, Marcelo; Yunis, Edmond J

    2010-02-01

    The most common test to identify latent tuberculosis is the tuberculin skin test that detects T cell responses of delayed type hypersensitivity type IV. Since it produces false negative reactions in active tuberculosis or in high-risk persons exposed to tuberculosis patients as shown in this report, we studied antibody profiles to explain the anergy of such responses in high-risk individuals without active infection. Our results showed that humoral immunity against tuberculin, regardless of the result of the tuberculin skin test is important for protection from active tuberculosis and that the presence of high antibody titers is a more reliable indicator of infection latency suggesting that latency can be based on the levels of antibodies together with in vitro proliferation of peripheral blood mononuclear cells in the presence of the purified protein derivative. Importantly, anti-tuberculin IgG antibody levels mediate the anergy described herein, which could also prevent reactivation of disease in high-risk individuals with high antibody titers. Such anti-tuberculin IgG antibodies were also found associated with blocking and/or stimulation of in vitro cultures of PBMC with tuberculin. In this regard, future studies need to establish if immune responses to Mycobacterium tuberculosis can generate a broad spectrum of reactions either toward Th1 responses favoring stimulation by cytokines or by antibodies and those toward diminished responses by Th2 cytokines or blocking by antibodies; possibly involving mechanisms of antibody dependent protection from Mtb by different subclasses of IgG. Published by Elsevier Ltd.

  18. Different relationships between personal exposure and ambient concentration by particle size.

    Science.gov (United States)

    Guak, Sooyoung; Lee, Kiyoung

    2018-04-06

    Ambient particulate matter (PM) concentrations at monitoring stations were often used as an indicator of population exposure to PM in epidemiological studies. The correlation between personal exposure and ambient concentrations of PM varied because of diverse time-activity patterns. The aim of this study was to determine the relationship between personal exposure and ambient concentrations of PM 10 and PM 2.5 with minimal impact of time-activity pattern on personal exposure. Performance of the MicroPEM, v3.2 was evaluated by collocation with central ambient air monitors for PM 10 and PM 2.5 . A field technician repeatedly conducted measurement of 24 h personal exposures to PM 10 and PM 2.5 with a fixed time-activity pattern of office worker over 26 days in Seoul, Korea. The relationship between the MicroPEM and the ambient air monitor showed good linearity. Personal exposure and ambient concentrations of PM 2.5 were highly correlated with a fixed time-activity pattern compared with PM 10 . The finding implied a high infiltration rate of PM 2.5 and low infiltration rate of PM 10 . The relationship between personal exposure and ambient concentrations of PM 10 and PM 2.5 was different for high level episodes. In the Asian dust episode, staying indoors could reduce personal exposure to PM 10 . However, personal exposure to PM 2.5 could not be reduced by staying indoors during the fine dust advisory episode.

  19. Analysis of plutonium-239 in occupationally exposed personnel; Analisis de plutonio-239 en personal ocupacionalmente expuesto

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez M, H., E-mail: hector.hernandez520@gmail.com [Universidad del Centro de Mexico, Capitan Caldera 75, Col. Tequixquiapan, 78250 San Luis Potosi, SLP (Mexico)

    2017-10-15

    Apart from radiometric techniques, several mass spectrometry (Ms) techniques can be used to evaluate the incorporation of plutonium-239 in occupationally exposed personnel, among which we can consider mass spectrometry with inductively coupled plasma source (Icp-Ms); mass spectrometry with accelerators (AMS); thermal ionization mass spectrometry (TIMS) and secondary ion mass spectrometry (Sims). In this work we evaluated analytical methods to measure isotopes of plutonium-239 in urine samples from occupationally exposed personnel, using alpha spectroscopy (As), magnetic sector mass spectrometry with inductively coupled plasma source (Icp-SFMS) and AMS. The samples were collected during 24 h were acidified with HNO{sub 3} at 5% in v/v. The processes used in the preparation of the samples were: a) co-precipitation, b) acid digestion, c) radiochemical separation and d) electro deposition. The results obtained in terms of minimum detectable activity of plutonium-239 were 0.1 μBq (∼ 0.4 fg per sample), 5.1 μBq (∼ 2 fg per sample), 30.1 μBq (∼ 13 fg per sample) and 0.1 μBq (∼ 51 fg per sample) for AMS, Aridus-Icp-SFMS, Icp, SFMS and As, respectively. On the other hand, samples previously analyzed by As were re-evaluated by Aridus-Icp-SFMS and AMS. The results show that extraction with 60 ml of 5% HNO{sub 3} at 60 degrees Celsius and for 2.5 h is enough to extract 90% of Pu electrodeposited on the planchette. In conclusion, AMS is an ultra-sensitive technique for determining isotope ratios of Pu, especially when is desired to validate a method to measure plutonium-239. Additionally, Icp-SFMS is a rapid analysis technique and can be used as a screening technique in situations of radiological incidents or accidents with Pu in the occupationally exposed personnel. Regarding alpha spectroscopy has been considered as the technique of excellence in the routine analysis to measure plutonium-239 in occupationally exposed personnel, due to the low cost. Finally, Icp

  20. Cytogenetic Analysis In Blood Lymphocyte From Workers Occupationally Exposed To Low Levels Of Radiation

    International Nuclear Information System (INIS)

    Rahimah Abdul Rahim; Mohd Rodzi Ali; Noraisyah Mohd Yusof; Juliana Mahamad Napiah; Yahaya Talib; Shafii Khamis

    2016-01-01

    Whether it comes from the ground, the sky, or medical treatment, humans are constantly exposed to ionizing radiation from the world around them. This is a normal occurrence, and has always been the case. According to the IAEA International Basic Safety Standard, the radiation dose for public is not more than 1 mSv per year. That is just an average though, and the actual figure may fluctuate widely per person depending on where they live and the medical procedures they had that year. The international standard is to allow people who work with and around radioactive material (researchers, nuclear power plant workers, X-ray technicians and others) to have exposures of not more than 20 mSv total per year. The 20 mSv annual dose is considered to be safe and not significantly increase the risk for radiation-related health effects. Biological dosimetry based on the analysis of micronuclei in the cytokinesis-block micronucleus (CBMN) assay can be used as an alternative method for scoring dicentric chromosomes in the field of radiation protection. Bio dosimetry is mainly performed, in addition to the physical dosimetry, with the aim of individual dose assessment. The aim of the present study was to perform a cytogenetic analysis in peripheral blood lymphocyte of 30 individuals occupationally exposed to low level of ionizing radiation and compare the result with 30 controls using CBMN assay. Number of bi-nucleated cell and micronuclei were scored and statistical analysis was done to see the effect of micronuclei with gender, age and occupation. In conclusion, scoring of micronuclei is a useful cytogenetic monitoring for radiation workers and assessment of genetic damage. (author)

  1. Neutron monitoring for radiological protection

    International Nuclear Information System (INIS)

    Gibson, J.A.B.

    1985-01-01

    Neutron monitoring is a subject of increasing general interest and considerable attention is being paid to the development of improved techniques and methods for neutron monitoring. The Agency, therefore, considered it important to prepare a guide on the subject of neutron monitoring for radiation protection purposes. The present Manual is intended for those persons or authorities in Member States, particularly developing countries, who are responsible for the organization of neutron monitoring programmes and practical neutron monitoring. This Manual consequently, deals with topics such as neutron dosimetry, sources of neutrons and neutron detection as well as field instruments and operational systems used in this context

  2. Organ doses and effective doses in some medical and industrial applications

    International Nuclear Information System (INIS)

    Keshavkumar, Biju

    2000-01-01

    The ICRP recommends radiation protection standards for the safe use of radiation and also prescribes the radiation protection quantities and periodically reviews them. In this context, the quantities like organ doses and effective doses are defined by ICRP. In this work we calculate these quantities and hence the conversion functions for the industrial radiation sources and those for CT and diagnostic X-ray exposures. Workers who are occupationally exposed to radiation are regularly monitored to evaluate the radiation dose received by them. It is quite possible that in an accident situation, the worker involved in the accident might not have worn a personal monitor, popularly known as the monitoring badge. In addition, even some non radiation workers (who are obviously not monitored) may also have received exposure. Under these circumstances, the persons involved are interviewed, the accident site inspected, and on the basis of realistic assumptions, the likely doses received by the exposed persons are estimated

  3. Assessment of Pupils’ Personal Achievements

    Directory of Open Access Journals (Sweden)

    T. A. Strokova

    2012-01-01

    Full Text Available The implementation of the new state educational standards, based on the competence approach, requires some new criteria, procedures and diagnostic tools for estimating pupils’ personal achievements. However, there is a lack of necessary guidelines and recommendations for such objective evaluation and comparative analysis of the effectiveness of educational establishments. The urgent need for unified monitoring instruments induced the author to develop a criteria-diagnostic complex providing the options for evaluating the important personal development aspects – intellectual, value-oriented and moral. The author recommends a self-assessment method for evaluating the intellectual qualities (i.e. self-dependency, critical thinking, logics, flexibility, depth, originality, etc., intellectual competences, and moral traits. The method is based on the tests – «Pupil in his own eyes» and «Pupil in the expert teachers’ eyes». For examining the value orientation, the author takes the classical method by M. Rokich. The approbation of the complex evaluation method was carried out in Tyumen schools and lyceums regarding the last year pupils. The research findings and proposed assessment tools can be used by headmasters and school teachers for monitoring the pupils’ personal growth. 

  4. 46 CFR 197.540 - Determination of personal exposure.

    Science.gov (United States)

    2010-10-01

    ... repeated for the operation when there has been a change in the procedure, equipment, or work practices of... when personal exposure has returned to the level that existed before the emergency. There must be... monitoring upon reasonable belief that the PEL's are being exceeded. (e) Notification of exposure monitoring...

  5. A posture recognition based fall detection system for monitoring an elderly person in a smart home environment.

    Science.gov (United States)

    Yu, Miao; Rhuma, Adel; Naqvi, Syed Mohsen; Wang, Liang; Chambers, Jonathon

    2012-11-01

    We propose a novel computer vision based fall detection system for monitoring an elderly person in a home care application. Background subtraction is applied to extract the foreground human body and the result is improved by using certain post-processing. Information from ellipse fitting and a projection histogram along the axes of the ellipse are used as the features for distinguishing different postures of the human. These features are then fed into a directed acyclic graph support vector machine (DAGSVM) for posture classification, the result of which is then combined with derived floor information to detect a fall. From a dataset of 15 people, we show that our fall detection system can achieve a high fall detection rate (97.08%) and a very low false detection rate (0.8%) in a simulated home environment.

  6. Mobile phones as monitors of personal exposure to air pollution: Is this the future?

    Directory of Open Access Journals (Sweden)

    Mawutorli Nyarku

    Full Text Available Mobile phones have a large spectrum of applications, aiding in risk prevention and improving health and wellbeing of their owners. So far, however, they have not been used for direct assessment of personal exposure to air pollution. In this study, we comprehensively evaluated the first, and the only available, mobile phone-BROAD Life-equipped with air pollution sensors (PM2.5 and VOC, to answer the question whether this technology is a viable option in the quest of reducing the burden of disease to air pollution. We tested its performance, applicability and suitability for the purpose by subjecting it to varied concentrations of different types of aerosol particles (cigarette smoke, petrol exhaust and concrete dust and formaldehyde under controlled laboratory conditions, as well as to ambient particles during field measurements. Six reference instruments were used in the study: AEROTRAK Optical Particle Counter (OPC model number 9306, DustTrak, Aerodynamic Particle Counter (APS, Scanning Mobility Particle Sizer (SMPS, Tapered Element Oscillating Microbalance (TEOM and Formaldehyde Analyser. Overall, we found that the phone's response was linear at higher particle number concentrations in the chamber, above 5 and 10 μg m-3, for combustion and concrete dust particles, respectively, and for higher formaldehyde concentrations, making it potentially suitable for applications in polluted environments. At lower ambient concentrations of particles around 10 ug m-3 and 20 μg m-3 for PM2.5 and PM10, respectively, the phone's response was below its noise level, suggesting that it is not suitable for ambient monitoring under relatively clean urban conditions. This mobile phone has a number of limitations that may hinder its use in personal exposure and for continuous monitoring. Despite these limitations, it may be used for comparative assessments, for example when comparing outcomes of intervention measures or local impacts of air pollution sources. It

  7. Mobile phones as monitors of personal exposure to air pollution: Is this the future?

    Science.gov (United States)

    Nyarku, Mawutorli; Mazaheri, Mandana; Jayaratne, Rohan; Dunbabin, Matthew; Rahman, Md Mahmudur; Uhde, Erik

    2018-01-01

    Mobile phones have a large spectrum of applications, aiding in risk prevention and improving health and wellbeing of their owners. So far, however, they have not been used for direct assessment of personal exposure to air pollution. In this study, we comprehensively evaluated the first, and the only available, mobile phone—BROAD Life—equipped with air pollution sensors (PM2.5 and VOC), to answer the question whether this technology is a viable option in the quest of reducing the burden of disease to air pollution. We tested its performance, applicability and suitability for the purpose by subjecting it to varied concentrations of different types of aerosol particles (cigarette smoke, petrol exhaust and concrete dust) and formaldehyde under controlled laboratory conditions, as well as to ambient particles during field measurements. Six reference instruments were used in the study: AEROTRAK Optical Particle Counter (OPC model number 9306), DustTrak, Aerodynamic Particle Counter (APS), Scanning Mobility Particle Sizer (SMPS), Tapered Element Oscillating Microbalance (TEOM) and Formaldehyde Analyser. Overall, we found that the phone’s response was linear at higher particle number concentrations in the chamber, above 5 and 10 μg m-3, for combustion and concrete dust particles, respectively, and for higher formaldehyde concentrations, making it potentially suitable for applications in polluted environments. At lower ambient concentrations of particles around 10 ug m-3 and 20 μg m-3 for PM2.5 and PM10, respectively, the phone’s response was below its noise level, suggesting that it is not suitable for ambient monitoring under relatively clean urban conditions. This mobile phone has a number of limitations that may hinder its use in personal exposure and for continuous monitoring. Despite these limitations, it may be used for comparative assessments, for example when comparing outcomes of intervention measures or local impacts of air pollution sources. It should

  8. Mobile phones as monitors of personal exposure to air pollution: Is this the future?

    Science.gov (United States)

    Nyarku, Mawutorli; Mazaheri, Mandana; Jayaratne, Rohan; Dunbabin, Matthew; Rahman, Md Mahmudur; Uhde, Erik; Morawska, Lidia

    2018-01-01

    Mobile phones have a large spectrum of applications, aiding in risk prevention and improving health and wellbeing of their owners. So far, however, they have not been used for direct assessment of personal exposure to air pollution. In this study, we comprehensively evaluated the first, and the only available, mobile phone-BROAD Life-equipped with air pollution sensors (PM2.5 and VOC), to answer the question whether this technology is a viable option in the quest of reducing the burden of disease to air pollution. We tested its performance, applicability and suitability for the purpose by subjecting it to varied concentrations of different types of aerosol particles (cigarette smoke, petrol exhaust and concrete dust) and formaldehyde under controlled laboratory conditions, as well as to ambient particles during field measurements. Six reference instruments were used in the study: AEROTRAK Optical Particle Counter (OPC model number 9306), DustTrak, Aerodynamic Particle Counter (APS), Scanning Mobility Particle Sizer (SMPS), Tapered Element Oscillating Microbalance (TEOM) and Formaldehyde Analyser. Overall, we found that the phone's response was linear at higher particle number concentrations in the chamber, above 5 and 10 μg m-3, for combustion and concrete dust particles, respectively, and for higher formaldehyde concentrations, making it potentially suitable for applications in polluted environments. At lower ambient concentrations of particles around 10 ug m-3 and 20 μg m-3 for PM2.5 and PM10, respectively, the phone's response was below its noise level, suggesting that it is not suitable for ambient monitoring under relatively clean urban conditions. This mobile phone has a number of limitations that may hinder its use in personal exposure and for continuous monitoring. Despite these limitations, it may be used for comparative assessments, for example when comparing outcomes of intervention measures or local impacts of air pollution sources. It should be kept

  9. A study of personality of leader and style of his co-operation in sporting command

    Directory of Open Access Journals (Sweden)

    Smolar I.I.

    2012-12-01

    Full Text Available The personality features of leader of sporting command and style of his co-operation are considered. The problems of adjusting and optimization of co-operation of leader and other players of command are selected in achievement of the set team purpose. 37 skilled sportsmen-handballers took part in research. An informal structure is exposed in commands, leaders and followers are certain. The quantitative indexes of personality features of leader, follower of sporting command are certain. Style of co-operation of leader and follower (prevailing and goodwill and quality is exposed personalities which will be realized by them in a sporting command. It is set that in interpersonality co-operation a leader will realize dominant style, and follower equal will realize dominant and benevolent styles.

  10. Findings of thyroid ultrasonography in patients with hypothyroidism exposed to ionizing radiation due to Chernobyl accident

    International Nuclear Information System (INIS)

    Grid'ko, O.M.

    1997-01-01

    Comparative analysis of the findings of clinical and ultrasound study of the thyroid gland in 403 participants of the accident clean-up irradiated in the 'iodine' period and 57 patients with hypothyroidism (of them, 46 were exposed to radiation in the 'iodine' period and 11 in 'non-iodine' one) was carried out. The disease dynamics was investigated in 81 patients with acute radiation sickness. The structural changes suggest different ways of hypothyroidism development in the exposed persons and manifest themselves in two main clinical forms of the disease, atrophic and hypertrophic ones

  11. Communication plan of GPS monitoring system based on the Internet

    Science.gov (United States)

    Xing, Xiangpeng; Liu, Zhenan; Bao, Yuanlu

    2005-11-01

    In GPS monitoring system, wireless communications network is necessary to keep base station in contact with mobile stations. Public communications network and personal communications network can't work well all the time. In this article, an economical communications network that can be competent for communication of GPS monitoring system is introduced. Personal communications network is used in this GPS monitoring system. In order to enlarge the coverage area and to expand the capacity of the personal communications network, the concept of cellular radio system is introduced. Because only the non-adjacent cells can use the same frequency channel, handoff of mobile station is extremely important when it goes in another cell. The mobile station of the system will know its own longitude and latitude by receiving data from GPS satellites all the time, so it can change its working frequency channel according to its position. Internet, instead of personal communication cable, is used to connect the base stations. So the communications network has the advantage of public communications network and personal one.

  12. Using a personal watercraft for monitoring bathymetric changes at storm scale

    NARCIS (Netherlands)

    Van Son, S.T.J.; Lindenbergh, R.C.; De Schipper, M.A.; De Vries, S.; Duijnmayer, K.

    2009-01-01

    Monitoring and understanding coastal processes is important for the Netherlands since the most densely populated areas are situated directly behind the coastal defense. Traditionally, bathymetric changes are monitored at annual intervals, although nowadays it is understood that most dramatic changes

  13. Personal Beacon

    Science.gov (United States)

    2000-01-01

    The MicroPLB (personal locator beacon) is a search and rescue satellite-aided tracking (SARSAT) transmitter. When activated it emits a distress signal to a constellation of internationally operated satellites. The endangered person's identity and location anywhere on Earth is automatically forwarded to central monitoring stations around the world. It is accurate to within just a few meters. The user uses the device to download navigation data from a global positioning satellite receiver. After the download is complete, the MicroPLB functions as a self-locating beacon. Also, it is the only PLB to use a safe battery. In the past, other PLB devices have used batteries that have enough volatility to explode with extreme force. It was developed by Microwave Monolithic, Inc. through SBIR funding from Glenn Research Center and Goddard Space Flight Center.

  14. Use of remote monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Fournel, E; Gouilloux, C

    1977-01-01

    Paper traces the development of remote monitoring devices, since their first appearance for safety purposes. Discusses their uses in coal mines: working and safety (definitions); sources and channels of information (transmission of information by automatic or verbal means); mine control stations; duties and responsibilities of persons in charge. Examines the contribution made by remote monitoring to management in production sector. Gives examples of assistance given to production management showing a very advantageous result on balance, by their use. The use of computers in real time and in batched mode is compared. Discusses their use in monitoring mine atmosphere. Very favorable results have already been obtained in France and abroad. The broadening scope and future of remote monitoring is considered.

  15. Reproductive function of animals exposed to low-dose external γ-radiation

    International Nuclear Information System (INIS)

    Izhevskij, P.V.; Krupitskaya, L.I.; Startsev, N.V.

    1993-01-01

    Chronic external γ-radiation effects on the reproductive function were simulated in male rats at doses equivalent to the dose obtained by the persons who participated in the liquidation of the Chernobyl poer plant accident aftereffects and by the population. The incidence of the pre-and postimplantation deaths was found increased in the progeny of males exposed to chronic external γ-irradiation at total doses of 158 and 237 Gy, though no strict dose dependence was observed

  16. An experience in the management of personal dosimetry and Information and Communication Technologies; Una experiencia en la gestión de la dosimetría personal y las Tecnologías de la Información y las Comunicaciones

    Energy Technology Data Exchange (ETDEWEB)

    Galán Montenegro, P.; Sánchez Hidalgo, M.; Bodineau, C.; Oliveros Fernández, B.

    2015-07-01

    One of the most frequently issues raised within the management of hospital personnel dosimetry service is the high incidence of the rate evidencing the lack of dosimeter badges replacement in personnel dosimetry on monthly basis. In this respect and following the enforcement of the dispositions ordered by the CSN (Spanish Nuclear Safety Council as Regulatory Agency) concerning the assignment of “administrative dose”, such rate turns currently into a high number of these doses assigned, thus leading to an inefficient monitoring of the personnel dosimetry. In order to achieve a more suitable dosimetry monitoring it is required a more direct and tailored management of personnel dosimetry in every occupationally exposed workers as well as providing with personal and fluent information. The total number of occupationally exposed workers and the diversity and geographical dispersion of the centers under dosimetry monitoring make impossible a customized management without involving substantial resources. With the aim of achieving a more tailored management in an scenario as the one described above as well as reducing the lack of replacement of dosimeter badges in personnel dosimetry on monthly basis and the administrative doses assigned, some measures were implemented in 2009 by applying Communications and Information Technology platforms and further employees management giving as a result a 75% reduction in the rate of non replacement of dosimeter badges in personnel dosimetry. [Spanish] Una de las cuestiones habitualmente planteada en la gestión de la dosimetría personal hospitalaria es la alta incidencia en la tasa de no recambio mensual de los dosímetros personales y desde la aplicación de la instrucción del Consejo de Seguridad Nuclear (CSN) sobre la asignación de la dosis administrativa, esto supone en la actualidad un alto número de las mencionadas asignaciones; lo que conlleva un deficiente control de la dosimetría personal. Para un mejor control dosim

  17. High-resolution mass spectrometry of skin mucus for monitoring physiological impacts and contaminant biotransformation products in fathead minnows exposed to wastewater effluent.

    Science.gov (United States)

    Mosley, Jonathan D; Ekman, Drew R; Cavallin, Jenna E; Villeneuve, Daniel L; Ankley, Gerald T; Collette, Timothy W

    2018-03-01

    High-resolution mass spectrometry is advantageous for monitoring physiological impacts and contaminant biotransformation products in fish exposed to complex wastewater effluent. We evaluated this technique using skin mucus from male and female fathead minnows (Pimephales promelas) exposed to control water or treated wastewater effluent at 5, 20, and 100% levels for 21 d, using an on-site, flow-through system providing real-time exposure. Both sex-specific and non-sex-specific responses were observed in the mucus metabolome, the latter suggesting the induction of general compensatory pathways for xenobiotic exposures. Altogether, 85 statistically significant treatment-dependent metabolite changes were observed out of the 310 total endogenous metabolites that were detected (156 of the 310 were annotated). Partial least squares-regression models revealed strong covariances between the mucus metabolomes and up-regulated hepatic messenger ribonucleic acid (mRNA) transcripts reported previously for these same fish. These regression models suggest that mucus metabolomic changes reflected, in part, processes by which the fish biotransformed xenobiotics in the effluent. In keeping with this observation, we detected a phase II transformation product of bisphenol A in the skin mucus of male fish. Collectively, these findings demonstrate the utility of mucus as a minimally invasive matrix for simultaneously assessing exposures and effects of environmentally relevant mixtures of contaminants. Environ Toxicol Chem 2018;37:788-796. Published 2017 Wiley Periodicals Inc. on behalf of SETAC. This article is a US government work and, as such, is in the public domain in the United States of America. Published 2017 Wiley Periodicals Inc. on behalf of SETAC. This article is a US government work and, as such, is in the public domain in the United States of America.

  18. Determination of intake and internal radiation dose for occupationally exposed workers to iodine 131

    International Nuclear Information System (INIS)

    Kharita, M. H.; Maghrabi, M.; Sadyya, A.

    2004-12-01

    Workers who prepare and inject radioactive Iodine I 131 doses at the medical centers in Syria are potentially exposed to the radioactive intake by ingestion or inhalation during preparation or injection processes. The received amount of the radioactive intake differs according to the amount of the I 131 that released during the preparation or injection processes, and to the work conditions and the applying ways of the radiation protection principles. Because of this radioactive intake, the thyroid gland may expose to amounts of I 131 which may negatively affect the health of the workers, so it is necessary to make routine monitoring for all workers who receive an intake of more than 10% of the annual intake limit which is (2*10 6 Bq/y) for I 131 . To make this monitoring process, it is necessary to use either the thyroid gland counter in order to know the concentrated amount of the radioactivity in the gland, or the analysis of a 24 hours urine sample of the exposed workers to determine the eliminated amount of the radioactivity using gamma spectrometry, also the two processes can be applied at the same time. Since the thyroid gland counter is not available, the analysis of urine sample was done to determine the concentrated amount of the radioactivity in urine, then to estimate the radioactive intake and the internal radioactive dose. The results of applying this method dictated that some workers work in safe conditions according to the radiation protection and there is no need for them to make routine monitoring . But the other workers receive a radioactive intake of about 10% yearly of the annual intake limit and that requires a routine periodical monitoring for those workers in addition to the necessity of applying the principles of the radiation protection during the work with I 131 . These principles and systems should indicate the basic requirement of radiation protection that must be available in the laboratory that deal with I 131 either for therapy or for

  19. Personality traits, self-care behaviours and glycaemic control in Type 2 diabetes

    DEFF Research Database (Denmark)

    Skinner, T. C.; Bruce, D. G.; Davis, T. M.E.

    2014-01-01

    Aims: To determine whether the personality traits of conscientiousness and agreeableness are associated with self-care behaviours and glycaemia in Type 2 diabetes. Methods: The Big Five Inventory personality traits Agreeableness, Conscientiousness, Extraversion, Neuroticism and Openness were...... modelling was used to determine whether personality was associated with BMI, smoking, self-monitoring of blood glucose and medication taking. Multivariable regression was used to investigate which traits were independently associated with these self-care behaviours and HbA1c. Results: Patients with higher......, longer diabetes duration, diabetes treatment, self-monitoring of blood glucose (negatively) and less medication taking (P ≤ 0.009), but no personality trait added to the model. Conclusions: Although there was no independent association between personality traits and HbA1c, the relationship between high...

  20. LGBT Monitor 2016

    NARCIS (Netherlands)

    Lisette Kuyper

    2016-01-01

    Original title: LHBT-monitor 2016 What is the public attitude today towards lesbian, homosexual, bisexual and transgender (LGBT) persons? What do large-scale population surveys enable us to say about their position in society? The Netherlands is one of the most positive countries in Europe in its

  1. Hearing damage by personal stereo

    DEFF Research Database (Denmark)

    Hammershøi, Dorte; Ordoñez, Rodrigo Pizarro; Reuter, Karen

    2006-01-01

    The technological development within personal stereo systems, such as MP3 players, iPods etc., has changed music listening habits from home entertainment to everyday and everywhere use. The technology has developed considerably, since the introduction of CD walkmen, and high-level low-distortion ......The technological development within personal stereo systems, such as MP3 players, iPods etc., has changed music listening habits from home entertainment to everyday and everywhere use. The technology has developed considerably, since the introduction of CD walkmen, and high-level low......-distortion music is produced by minimal devices. In this paper, the existing literature on effects of personal stereo systems is reviewed, incl. studies of exposure levels, and effects on hearing. Generally, it is found that the levels being used is of concern, which in one study [Acustica?Acta Acustica, 82 (1996......) 885?894] is demonstrated to relate to the specific use in situations with high levels of background noise. Another study [Med. J. Austr., 1998; 169: 588-592], demonstrates that the effect of personal stereo is comparable to that of being exposed to noise in industry. The results are discussed in view...

  2. Apparatuses and methods of determining if a person operating equipment is experiencing an elevated cognitive load

    Science.gov (United States)

    Watkins, Michael L.; Keller, Paul Edwin; Amaya, Ivan A.

    2015-06-16

    A method of, and apparatus for, determining if a person operating equipment is experiencing an elevated cognitive load, wherein the person's use of a device at a first time is monitored so as to set a baseline signature. Then, at a later time, the person's use of the device is monitored to determine the person's performance at the second time, as represented by a performance signature. This performance signature can then be compared against the baseline signature to predict whether the person is experiencing an elevated cognitive load.

  3. Potassium ion influx measurements on cultured Chinese hamster cells exposed to 60-hertz electromagnetic fields

    International Nuclear Information System (INIS)

    Stevenson, A.P.; Tobey, R.A.

    1985-01-01

    Potassium ion influx was measured by monitoring 42 KCl uptake by Chinese hamster ovary (CHO) cells grown in suspension culture and exposed in the culture medium to 60-Hz electromagnetic fields up to 2.85 V/m. In the presence of the field CHO cells exhibited two components of uptake, the same as previously observed for those grown under normal conditions; both these components of influx were decreased when compared to sham-exposed cells. Although decreases were consistently observed in exposed cells when plotted as loge of uptake, the differences between the means of the calculated fluxes of exposed and sham-exposed cells were quite small (on the order of 4-7%). When standard deviations were calculated, there was no significant difference between these means; however, when time-paired uptake data were analyzed, the differences were found to be statistically significant. Cells exposed only to the magnetic field exhibited similar small decreases in influx rates when compared to sham-exposed cells, suggesting that the reduction in K+ uptake could be attributed to the magnetic field. Additionally, intracellular K+ levels were measured over a prolonged exposure period (96 h), and no apparent differences in intracellular K+ levels were observed between field-exposed and sham-exposed cultures. These results indicate that high-strength electric fields have a small effect on the rate of transport of potassium ions but no effect on long-term maintenance of intracellular K+

  4. On the Move to Business-Driven Alignment of Service Monitoring Requirements

    OpenAIRE

    Alencar Silva , Patrício ,; Weigand , Hans

    2011-01-01

    Part 2: Full Papers; International audience; Current service monitoring capabilities have been not designed in alignment with business needs. We argue that service monitoring should be primarily thought of as an economic concern, with proper needs being elicited on the business strategy level and further drilled down to process and IT services management layers. Monitoring needs and capabilities should be designed independently from each other and exposed as abstract monitoring interfaces for...

  5. The power grid monitoring promotion of Liaoning December 14th accident

    Science.gov (United States)

    Zhou, Zhi; Gao, Ziji; He, Xiaoyang; Li, Tie; Jin, Xiaoming; Wang, Mingkai; Qu, Zhi; Sun, Chenguang

    2018-02-01

    This paper introduces the main responsibilities of power grid monitoring and the accident of Liaoning Power Grid 500kV Xujia transformer substation at December 14th, 2016. This paper analyzes the problems exposed in this accident from the aspects of abnormal information judgment, fault information collection, auxiliary video monitoring, online monitoring of substation equipment, puts forward the corresponding improvement methods and summarizes the methods of improving the professional level of power grid equipment monitoring.

  6. System And Method For Monitoring Traffic While Preserving Personal Privacy

    KAUST Repository

    Canepa, Edward

    2015-08-06

    A traffic monitoring system and method for mapping traffic speed and density while preserving privacy. The system can include fixed stations that make up a network and mobile probes that are associated with vehicles. The system and method do not gather, store, or transmit any unique or identifying information, and thereby preserves the privacy of members of traffic. The system and method provide real-time traffic density and speed mapping. The system and method can further be integrated with a complementary flood monitoring system and method.

  7. Occupational determinants of serum cholinesterase inhibition among organophosphate-exposed agricultural pesticide handlers in Washington State

    Science.gov (United States)

    Hofmann, Jonathan N; Keifer, Matthew C; De Roos, Anneclaire J; Fenske, Richard A; Furlong, Clement E; van Belle, Gerald; Checkoway, Harvey

    2010-01-01

    Objective To identify potential risk factors for serum cholinesterase (BuChE) inhibition among agricultural pesticide handlers exposed to organophosphate (OP) and N-methyl-carbamate (CB) insecticides. Methods We conducted a longitudinal study among 154 agricultural pesticide handlers who participated in the Washington State cholinesterase monitoring program in 2006 and 2007. BuChE inhibition was analyzed in relation to reported exposures before and after adjustment for potential confounders using linear regression. Odds ratios estimating the risk of ‘BuChE depression’ (>20% from baseline) were also calculated for selected exposures based on unconditional logistic regression analyses. Results An overall decrease in mean BuChE activity was observed among study participants at the time of follow-up testing during the OP/CB spray season relative to pre-season baseline levels (mean decrease of 5.6%, P < 0.001). Score for estimated cumulative exposure to OP/CB insecticides in the past 30 days was a significant predictor of BuChE inhibition (β = −1.74, P < 0.001). Several specific work practices and workplace conditions were associated with greater BuChE inhibition, including mixing/loading pesticides and cleaning spray equipment. Factors that were protective against BuChE inhibition included full-face respirator use, wearing chemical-resistant boots, and storing personal protective equipment in a locker at work. Conclusions Despite existing regulations, agricultural pesticide handlers continue to be exposed to OP/CB insecticides at levels resulting in BuChE inhibition. These findings suggest that modifying certain work practices could potentially reduce BuChE inhibition. Replication from other studies will be valuable. PMID:19819864

  8. Lifting strength in two-person teamwork.

    Science.gov (United States)

    Lee, Tzu-Hsien

    2016-01-01

    This study examined the effects of lifting range, hand-to-toe distance, and lifting direction on single-person lifting strengths and two-person teamwork lifting strengths. Six healthy males and seven healthy females participated in this study. Two-person teamwork lifting strengths were examined in both strength-matched and strength-unmatched groups. Our results showed that lifting strength significantly decreased with increasing lifting range or hand-to-toe distance. However, lifting strengths were not affected by lifting direction. Teamwork lifting strength did not conform to the law of additivity for both strength-matched and strength-unmatched groups. In general, teamwork lifting strength was dictated by the weaker of the two members, implying that weaker members might be exposed to a higher potential danger in teamwork exertions. To avoid such overexertion in teamwork, members with significantly different strength ability should not be assigned to the same team.

  9. Assessment of toxic metals in waste personal computers

    International Nuclear Information System (INIS)

    Kolias, Konstantinos; Hahladakis, John N.; Gidarakos, Evangelos

    2014-01-01

    Highlights: • Waste personal computers were collected and dismantled in their main parts. • Motherboards, monitors and plastic housing were examined in their metal content. • Concentrations measured were compared to the RoHS Directive, 2002/95/EC. • Pb in motherboards and funnel glass of devices released <2006 was above the limit. • Waste personal computers need to be recycled and environmentally sound managed. - Abstract: Considering the enormous production of waste personal computers nowadays, it is obvious that the study of their composition is necessary in order to regulate their management and prevent any environmental contamination caused by their inappropriate disposal. This study aimed at determining the toxic metals content of motherboards (printed circuit boards), monitor glass and monitor plastic housing of two Cathode Ray Tube (CRT) monitors, three Liquid Crystal Display (LCD) monitors, one LCD touch screen monitor and six motherboards, all of which were discarded. In addition, concentrations of chromium (Cr), cadmium (Cd), lead (Pb) and mercury (Hg) were compared with the respective limits set by the RoHS 2002/95/EC Directive, that was recently renewed by the 2012/19/EU recast, in order to verify manufacturers’ compliance with the regulation. The research included disassembly, pulverization, digestion and chemical analyses of all the aforementioned devices. The toxic metals content of all samples was determined using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). The results demonstrated that concentrations of Pb in motherboards and funnel glass of devices with release dates before 2006, that is when the RoHS Directive came into force, exceeded the permissible limit. In general, except from Pb, higher metal concentrations were detected in motherboards in comparison with plastic housing and glass samples. Finally, the results of this work were encouraging, since concentrations of metals referred in the RoHS Directive were found in

  10. Assessment of toxic metals in waste personal computers

    Energy Technology Data Exchange (ETDEWEB)

    Kolias, Konstantinos; Hahladakis, John N., E-mail: john_chach@yahoo.gr; Gidarakos, Evangelos, E-mail: gidarako@mred.tuc.gr

    2014-08-15

    Highlights: • Waste personal computers were collected and dismantled in their main parts. • Motherboards, monitors and plastic housing were examined in their metal content. • Concentrations measured were compared to the RoHS Directive, 2002/95/EC. • Pb in motherboards and funnel glass of devices released <2006 was above the limit. • Waste personal computers need to be recycled and environmentally sound managed. - Abstract: Considering the enormous production of waste personal computers nowadays, it is obvious that the study of their composition is necessary in order to regulate their management and prevent any environmental contamination caused by their inappropriate disposal. This study aimed at determining the toxic metals content of motherboards (printed circuit boards), monitor glass and monitor plastic housing of two Cathode Ray Tube (CRT) monitors, three Liquid Crystal Display (LCD) monitors, one LCD touch screen monitor and six motherboards, all of which were discarded. In addition, concentrations of chromium (Cr), cadmium (Cd), lead (Pb) and mercury (Hg) were compared with the respective limits set by the RoHS 2002/95/EC Directive, that was recently renewed by the 2012/19/EU recast, in order to verify manufacturers’ compliance with the regulation. The research included disassembly, pulverization, digestion and chemical analyses of all the aforementioned devices. The toxic metals content of all samples was determined using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). The results demonstrated that concentrations of Pb in motherboards and funnel glass of devices with release dates before 2006, that is when the RoHS Directive came into force, exceeded the permissible limit. In general, except from Pb, higher metal concentrations were detected in motherboards in comparison with plastic housing and glass samples. Finally, the results of this work were encouraging, since concentrations of metals referred in the RoHS Directive were found in

  11. Health surveillance of persons occupationally exposed to ionizing radiation: Guidance for occupational physicians

    International Nuclear Information System (INIS)

    1998-01-01

    This Safety Report is intended mainly for occupational physicians, as well as for occupational health service personnel, to assist them in routine practice by specifying the features of work under radiation conditions, the general rules of radiological protection for occupational exposure and the organization of the medical surveillance of workers occupationally exposed to radiation. The Report is consistent with the recommendations of the International Commission on Radiological Protection presented in its Publication 60 (1990) and with the International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources published by the IAEA in 1966. It supersedes Safety Series No.83 (Radiation Protection in Occupational Health: Manual for Occupational Physicians) published by the IAEA in 1987

  12. Differential pattern of deposition of nanoparticles in the airways of exposed workers

    Energy Technology Data Exchange (ETDEWEB)

    Fireman, Elizabeth, E-mail: fireman@tlvmc.gov.il [Tel Aviv University, Laboratory of Pulmonary and Allergic Diseases (Israel); Edelheit, Rinat [Tel Aviv University, Department of Occupational and Environmental Health School of Public Health, Sackler Faculty of Medicine (Israel); Stark, Moshe [Tel Aviv University, Laboratory of Pulmonary and Allergic Diseases (Israel); Shai, Amir Bar [Tel Aviv University, Pulmonology Department, Tel-Aviv Sourasky Medical Center affiliated to the Sackler Faculty of Medicine (Israel)

    2017-02-15

    Ultrafine particles (UFP) have been postulated to significantly contribute to the adverse health effects associated with exposure to particulate matter (PM). Due to their extremely small size (aerodynamic diameter <100 nm), UFP are able to deposit deep within the lung after inhalation and evade many mechanisms responsible for the clearance of larger particles. There is a lack of biologically relevant personal exposure metrics for exposure to occupational- and environmental-related micro- and nano-sized PM. The aim of the present study is to assess UFP in induced sputum (IS) and exhaled breath condensate (EBC) as possible biomarkers for assessing lung function impairment. Sputum induction and EBC testing were performed by conventional methods. UFP particles were assessed with the NanoSight LM20 (NanoSight Ltd, London, UK). The subjects included 35 exposed and 25 non-exposed workers. There were no group differences in pulmonary function test results and differential cell counts, but 63.6% of the exposed subjects had a higher percentage of neutrophils (OR3.28 p = 0.03) compared to the non-exposed subjects. The exposed subjects had higher percentages of UFP between 10 and 50 nm (69.45 ± 18.70 vs 60.11 ± 17.52 for the non-exposed group, p = 0.004). No differences were found in the IS samples. Years of exposure correlated positively to UFP content (r = 0.342 p = 0.01) and macrophage content (r = −0.327 p = 0.03). The percentage of small fraction of UFP in EBC, but not IS, is higher in exposed workers, and EBC may be a sensitive biomarker to assess exposure to nanoparticles.

  13. Organization of the individual monitoring in Brazil

    International Nuclear Information System (INIS)

    Cunha, P.

    1991-01-01

    There are about 35,000 workers monitored in Brazil. Most of them are employed onhealth and non-nuclear industrial areas. The external individual monitoring is done by 10 laboratories accredited by the Brazilian Nuclear Energy Commission, CNEN, applying specific regulation. The personal date and doses of the monitored workers are stored in a data bank. In this paper, future improvements are also discussed. (orig.)

  14. 125I and 123I monitoring at the working-places of the Eidg. Institut fuer Reaktorforschung (EIR) at Wuerenlingen (Switzerland)

    International Nuclear Information System (INIS)

    Goerlich, W.; Baechli, H.R.; Baur, W.; Koch, H.

    1976-01-01

    A group of persons exposed to radiation for professional reasons was monitored in EIR by means of thyroid and urin tests during one year. To determine the incorporation risk at the working-place wipe tests and air filter samples were carried out daily during the same time. The activities determined in the urin vary between 0,3% and 6% of the thyroid depot. The urin measurements are suitable for the manifestation of the incorporation. But to evaluate these the individual iod-excretion-rate must be determined before. The results of the measurements, the measuring devices, and the methods are explained. Incorporation was caused by improper storage of preparations and wastes, insufficient aeration, and imperfect methods. (orig./HP) [de

  15. Maintenance experiences with hand and foot monitor for monitoring alpha and beta radiation of personnel in NFC

    International Nuclear Information System (INIS)

    Ramachandra Rao, A.; Kulkarni, R.S.; Banerjee, P.K.

    2010-01-01

    NFC is producing natural uranium and enriched uranium fuels for various reactors including PHWR etc. Monitoring of α and β radiations in the active plants of NFC is very much essential in many aspects. The personnel who are handling radiation materials have to be monitored for α radiation of hands and cloths and β radiation of feet. So the Alpha and Beta Monitor became important monitoring equipment for monitoring α and β radiations of persons working in active plants of NFC. Many Alpha and Beta Monitors of make, ECIL, PLA, and Nucleonix etc. were being used in active plants in NFC. Basically α and β radiation monitors consists of four PMT (Photo Multiplier Tubes) for detection of radiation of hands and one PMT for monitoring clothes. The PMT use ZnS (Ag) as the scintillator for detection of α radiation. GM tubes are used to detect β radiation of feet. The latest Hand and Foot Monitors have been incorporated with PC based monitoring system along with software for making the monitoring process more efficient and user friendly. As an instrumentation maintenance team for these monitors, our experiences are varied. These monitors are to be periodically maintained and tested for its effective functioning in monitoring the nuclear radiation. The monitors procured from M/s. ECIL were being used since long time in these areas. The instrumentation maintenance had faced some problems with these monitors such as frequent failure of High Voltage cards, Amplifier and Counter PCB cards. Modifications were made in the circuits of High Voltage and Counter cards to minimize the failure rate and for loading of Display and Monitoring Software through Hard disk instead of from floppy disk. So the availability of monitors for monitoring radiation got improved. Later the introduction of more sophisticated α and β radiation monitors of M/s. PLA make in these areas further improved monitoring of radiation of personnel working in active areas. These monitors are more user

  16. Transition in occupational radiation exposure monitoring methods in diagnostic and interventional radiology

    International Nuclear Information System (INIS)

    Loennroth, N.; Hirvonen-Kari, M.; Timonen, M.; Savolainen, S.; Kortesniemi, M.

    2008-01-01

    Radiation exposure monitoring is a traditional keystone of occupational radiation safety measures in medical imaging. The aim of this study was to review the data on occupational exposures in a large central university hospital radiology organisation and propose changes in the radiation worker categories and methods of exposure monitoring. An additional objective was to evaluate the development of electronic personal dosimeters and their potential in the digitised radiology environment. The personal equivalent dose of 267 radiation workers (116 radiologists and 151 radiographers) was monitored using personal dosimeters during the years 2006-2010. Accumulated exposure monitoring results exceeding the registration threshold were observed in the personal dosimeters of 73 workers (59 radiologists' doses ranged from 0.1 to 45.1 mSv; 14 radiographers' doses ranged from 0.1 to 1.3 mSv). The accumulated personal equivalent doses are generally very small, only a few angiography radiologists have doses >10 mSv per 5 y. The typical effective doses are -1 and the highest value was 0.3 mSv (single interventional radiologist). A revised categorisation of radiation workers based on the working profile of the radiologist and observed accumulated doses is justified. Occupational monitoring can be implemented mostly with group dosimeters. An active real-time dosimetry system is warranted to support radiation protection strategy where optimisation aspects, including improving working methods, are essential. (authors)

  17. Personal exposure to PM2.5, black smoke and NO2 in Copenhagen: relationship to bedroom and outdoor concentrations covering seasonal variation.

    Science.gov (United States)

    Sørensen, Mette; Loft, Steffen; Andersen, Helle Vibeke; Raaschou-Nielsen, Ole; Skovgaard, Lene Theil; Knudsen, Lisbeth E; Nielsen, Ivan V; Hertel, Ole

    2005-09-01

    Epidemiological studies have found negative associations between human health and particulate matter in urban air. In most studies outdoor monitoring of urban background has been used to assess exposure. In a field study, personal exposure as well as bedroom, front door and background concentrations of PM(2.5), black smoke (BS), and nitrogen dioxide (NO(2)) were measured during 2-day periods in 30 subjects (20-33 years old) living and studying in central parts of Copenhagen. The measurements were repeated in the four seasons. Information on indoor exposure sources such as environmental tobacco smoke (ETS) and burning of candles was collected by questionnaires. The personal exposure, the bedroom concentration and the front door concentration was set as outcome variable in separate models and analysed by mixed effect model regression methodology, regarding subject levels as a random factor. Seasons were defined as a dichotomised grouping of outdoor temperature (above and below 8 degrees C). For NO(2) there was a significant association between personal exposure and both the bedroom, the front door and the background concentrations, whereas for PM(2.5) and BS only the bedroom and the front door concentrations, and not the background concentration, were significantly associated to the personal exposure. The bedroom concentration was the strongest predictor of all three pollution measurements. The association between the bedroom and front door concentrations was significant for all three measurements, and the association between the front door and the background concentrations was significant for PM(2.5) and NO(2), but not for BS, indicating greater spatial variation for BS than for PM(2.5) and NO(2). For NO(2), the relationship between the personal exposure and the front door concentration was dependent upon the "season", with a stronger association in the warm season compared with the cold season, and for PM(2.5) and BS the same tendency was seen. Time exposed to

  18. Micronuclei frequency in albino rats exposed to high natural radiation

    International Nuclear Information System (INIS)

    Aneesh, D.; Godwin Wesley, S.

    2013-01-01

    Genotoxicity and DNA damage endpoints are used to evaluate results in the context of cell survival. Genotoxicity in mammalian cells is monitored mostly by using cytokinesis-block micronucleus (CBMN) assay. The score of micronuclei (MN) in peripheral blood lymphocytes can be used as a biomarker and also as a bio-dosimeter of radiation exposure. In the present study the effect of natural radiation on albino rats has been investigated, to find out if there is any increase in MN frequency in peripheral blood lymphocytes. Animals at the age of 2-3 weeks were exposed to natural radiation, at the dose of 10.38 μGyh -1 for a period of 6 months. A parallel control set was also maintained (0.12 μGy h -1 '). Blood samples were collected from both test (exposed to natural radiation) and control rats. Lymphocyte culture was done following 'microculture techniques' for 72 h. Cytochalasin B, at a concentration of 6.0 μg/ml, was added to the lymphocyte cultures at 44 h to block cytokinesis. The frequency of MN was evaluated by scoring a total of 1000 binucleated (BN) cells from one slide. The frequency of MN among the rats exposed to natural radiation was found to be 1.83±0.05 per 1000 BN cells and in the control it was 1.82±0.07 per 1000 BN cells. No statistically significant difference in the MN frequencies of exposed and control groups (p>0.05) was seen. The lower MN frequency in natural radiation exposed rats could be an indication of adaptive response. (author)

  19. Study of the personal dosimetry service by thermoluminiscence

    International Nuclear Information System (INIS)

    Penaherrera, Patricio; Buitron, Susana; Prado, Elizabeth; Ceron Fabiola

    1992-01-01

    This paper is concerned with the personal dosimetry service given by the Ecuadorian Atomic Energy Commission to radiation exposed workers in Ecuador. The study has taken in consideration the number of professionals working in Ecuador by province and by area of work, and also the radiation doses received by them during the period 1987-1990

  20. Urine mutagenicity of steel workers exposed to coke oven emissions

    Energy Technology Data Exchange (ETDEWEB)

    De Meo, M.P.; Dumenil, G.; Botta, A.H.; Laget, M.; Zabaloueff, V.; Mathias, A.

    1987-03-01

    Urine mutagenicity of 19 individuals was investigated at a steel mill. All the subjects worked on the coal processing unit. Urine samples were collected at the end of a working day. Urine samples of two exposed workers were collected at the end of two periods of rest and two periods of working. Mutagens were extracted on XAD-2 resin and tested by the Salmonella microsomal assay and the SOS spot test. Mutagenic potencies of exposed smokers and exposed non-smokers were 8.62 +/- 6.56 and 1.1 +/- 0.48 revertants/mg creatinine respectively with Salmonella typhimurium strain TA98 + S9. Both values were significantly higher than those of unexposed smokers and non-smokers (5.07 +/- 3.33 and 0.47 +/- 0.72 revertants/mg creatinine respectively). The urinary mutagenic potency of the two exposed individuals increased at the end of periods of working (15.97 +/- 2.57 revertants/mg creatinine) and decreased at the end of periods of rest (12.31 +/- 2.45 revertants/mg creatinine). Urinary mutagens were detected with S. typhimurium strain TA100 + S9 to a lesser extent. No direct-acting mutagens were detected by the SOS spot test. Atmospheric benzo(a)pyrene (BaP) were also measured by h.p.l.c. on the coke battery. BaP concentrations ranged between 0.01 and 0.6 microgram/m3 air at the different working sites. Biological monitoring with short-term tests is discussed.

  1. Follow-up study of abnormal biological indicators and gene expression in the peripheral blood of three accidentally exposed persons

    International Nuclear Information System (INIS)

    Chi Cuiping; Wang Haiyan; Wei Jinping; Guo Jianping; Li Shufang; Tian Rong; Guo Fengling; Liu Huifang

    2013-01-01

    In order to identify biomarkers for early diagnosis and/or for therapeutic targets in the delayed health effects of ionizing radiation, we analyzed the subgroups of lymphocytes, serum protein levels and gene expression profiles in the peripheral blood of three 60 Co γ-ray accidentally exposed persons during the three years after irradiation. Flow cytometry analyses and agarose gel electrophoresis were applied to investigate the subgroups of lymphocytes and the composition of serum proteins, respectively. Gene expression profiling was obtained using a whole genome gene expression chip assay. Both the percentage of CD4+ T lymphocytes and the ratio of Th to Ts were reduced compared with the normal control values. The percentage of albumin decreased whereas beta globulin increased. There were 285 up-regulated and 446 down-regulated genes in irradiated samples relative to the control samples. The expression of KDR, CEACAM8 and OSM was validated by RT-PCR. The majority of the differentially expressed genes encode proteins associated with the immune response, inflammation, oncogenesis, cell structure, oxidative stress, neuro-hormone regulation, reproduction, susceptibility to psychiatric disorders, or transcriptional regulation. We have identified a number of promising novel candidates that have potential for serving as biomarkers for delayed damage. Furthermore, the changes in the immunological indicator CD4+ T cells, and the ratio of CD4+ T to CD8+ T cells may be biomarkers for the prediction of delayed damage by ionizing radiation. The findings of our study are useful for forming a comprehensive understanding of the mechanisms underlying the delayed effects of ionizing radiation. (author)

  2. RTP Radiation Monitoring System

    International Nuclear Information System (INIS)

    Alfred, S.L.; Mohd Fairus Abdul Farid; Ahmad Nabil Abdul Rahim; Nurhayati Ramli

    2015-01-01

    Radiation Monitoring System aiming to limiting dose exposed to personnel to the lowest level referring to the concept of ALARA (As Low As Reasonably Achievable). Atomic Energy Licensing (Basic Safety Radiation Protection) Regulation 2010 (Act 304) is a baseline to control employee and public radiation protection program and guideline, as well as to meet the requirement of the Occupational Safety and Health 1994 (Act 514). (author)

  3. Study of thorium internal monitoring program by radiotoxicological analysis

    International Nuclear Information System (INIS)

    Gaburo, J.; Sordi, G.-M.A.A.

    1986-01-01

    The aim of this work is the establishment of a bioassay routine monitoring program for thorium occupationally exposed personnel. A simple and economic method for the analytical determination of the concentration of Th-232 in excreta samples was adopted, using Th-229 as a tracer. The mean yield of the method was 80%. Thorium concentration in excreta samples of non occupationally exposed Rio de Janeiro and Sao Paulo inhabitants was compared with data provenient from Nuclemon workers, with a exposition history to the nuclide of more than ten years and from IPEN workers only recently occupationally exposed to the nuclide. (Author) [pt

  4. Effect of Nanoparticles Exposure on Fractional Exhaled Nitric Oxide (FENO in Workers Exposed to Nanomaterials

    Directory of Open Access Journals (Sweden)

    Wei-Te Wu

    2014-01-01

    Full Text Available Fractional exhaled nitric oxide (FENO measurement is a useful diagnostic test of airway inflammation. However, there have been few studies of FENO in workers exposed to nanomaterials. The purpose of this study was to examine the effect of nanoparticle (NP exposure on FENO and to assess whether the FENO is increased in workers exposed to nanomaterials (NM. In this study, both exposed workers and non-exposed controls were recruited from NM handling plants in Taiwan. A total of 437 subjects (exposed group = 241, non-exposed group = 196 completed the FENO and spirometric measurements from 2009–2011. The authors used a control-banding (CB matrix to categorize the risk level of each participant. In a multivariate linear regression analysis, this study found a significant association between risk level 2 of NP exposure and FENO. Furthermore, asthma, allergic rhinitis, peak expiratory flow rate (PEFR, and NF-κB were also significantly associated with FENO. When the multivariate logistic regression model was adjusted for confounders, nano-TiO2 in all of the NM exposed categories had a significantly increased risk in FENO > 35 ppb. This study found associations between the risk level of NP exposure and FENO (particularly noteworthy for Nano-TiO2. Monitoring FENO in the lung could open up a window into the role nitric oxide (NO may play in pathogenesis.

  5. Personal exposures of preschool children to carbon monoxide and nitrogen dioxide. The role of gas stoves

    Energy Technology Data Exchange (ETDEWEB)

    Alm, S.; Jantunen, M.J.; Mukala, K.; Tuomisto, J. [National Public Health Institute, Kuopio (Finland). Div. of Environmental Health; Pasanen, P. [Kuopio Univ. (Finland)

    1993-12-31

    Personal 1-h mean CO exposures of preschool children in two day care centers of Helsinki were measured with continuously recording personal exposure monitors, and their personal 1-wk NO{sub 2} exposures with Palmes tubes. The results were compared to fixed site ambient air monitoring results and related to the presence of high CO, low heat value town gas fired stoves in the homes of the children. Results show that fixed site ambient air monitors are of little value in predicting personal exposures of children or even their relative differences between areas, and also that town gas fired stoves have a profound effect on the CO exposures, and little or no effect on the NO{sub 2} exposures of the children. (author)

  6. Statistical results 1991-1993 of the Official Personal Dosimetry Service

    International Nuclear Information System (INIS)

    Boerner, E.; Drexler, G.; Wittmann, A.

    1995-01-01

    The report consists of a summary of relevant statistical data in the official personal dosimetry in 1988-1990 for the Federal States of Bavaria, Hesse, Schleswig-Holstein, and Baden-Wuerttemberg. The data are based on the survey of more than 8000 institutions with over 140000 occupational exposed persons and are derived from more than one million single measurements. The report covers informations on the institutions, on the persons as well as dosimetric values. The measuring method is described briefly with respect to dosimeters used, their range and the interpretation of values. Information on notional doses and the interpolation of values nearby the detection limits are given. (HP) [de

  7. Monitoring and assessment of individual doses of occupationally exposed workers due to intake of radionuclides

    International Nuclear Information System (INIS)

    Alexander, O. A.

    2014-04-01

    Monitoring and estimation of individual intakes of radionuclides can be complex. Doses of intakes cannot be measured directly, however must be assessed from the monitoring data of the individual. The individual monitoring data includes whole body counting, excretion analysis (urine or faecal). In the estimation of these data requires that the assessor makes assumptions about the exposure scenario, including the pattern and mode of radionuclide intake. Also physicochemical characteristics of the material involved and the period of time between exposure and measurement. This project report seeks to provide some underlying guidance on monitoring programmes and data interpretation using case study. In this present study the committed effective dose (CED) 1.20mSv exceeded the recording level (i.e. 1mSv) however it was below the investigation level (i.e. 2mSv). The present study recommends that as an essential part in internal dosimetry, specialists be capable of recognizing conditions warranting follow-up bioassay and dose evaluation. Personnel should be familiar with the relevant internal dosimetry literature and the recommendations of national and international scientific organizations with regard to internal dose. (au)

  8. Overview of individual monitoring and calibration of radiation monitors in the country; Panorama da monitoração individual e calibração de monitores de radiação no país

    Energy Technology Data Exchange (ETDEWEB)

    Alencar, M.A.V.; Patrão, K.C.S.; Ferreira, P.R.R.; Matta, L.E.S.C.; Peres, S.S.; Silva, F.C.A. da, E-mail: vallim@ird.gov.br [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Since 1995, the Institute of Radioprotection and Dosimetry (IRD/CNEN-RJ) has been responsible for the certification of instrument calibration laboratories and monitoring of occupationally exposed individuals (IOE), as well as monitoring and auditing the activities of eleven individual monitoring services (SMIE) and six instrument calibration laboratories (LCI) in the country. The work presents an overview of the number of IOE monitored and calibrated radiation monitors, from 2008 to 2016. The data were obtained through a census with the SMIE and LCI. The results show that in this period there was an increase of around 47% in the total number of IOE monitored and approximately 40% in the number of instrument calibrations. It was also observed the reduction of dosimetric film use and the beginning of OSLD monitoring.

  9. Brain abnormalities among the mentally retarded prenatally exposed atomic bomb survivors

    International Nuclear Information System (INIS)

    Schull, W.J.; Otake, Masanori; Nishitani, Hiromu; Hasuo, Kanehiro; Kobayashi, Takuro; Goto, Ikuo.

    1992-07-01

    An increased occurrence of severe mental retardation, with or without accompanying small head size, at specific gestational ages has been the most conspicuous effect on brain development of prenatal exposure to the bombings of Hiroshima and Nagasaki. A variety of biological mechanisms could be responsible for this finding, including cell killing and mismanaged neuronal migration. We describe here the findings on magnetic resonance imaging of the brains of five of these mentally retarded individuals, all of whom were exposed in the 8th through the 15th weeks following fertilization, the gestational period shown to be the most vulnerable to radiation-related damage. In the two cases exposed at the 8th or 9th week following fertilization, large areas of ectopic gray matter are seen, strong evidence of a failure of the neurons to migrate to their proper functional sites. The two individuals exposed in the 12th or 13th week show no readily recognized ectopic gray areas but do show mild macrogyria, which implies some impairment in the development of the cortical zone. Moreover, both have mega cisterna magna. Finally, the one individual seen who was exposed still later in development, in the 15th week, shows none of the changes seen in the other four individuals. This person's brain, though small, appears to have normal architecture. These findings are discussed in terms of the embryological events transpiring at the time of the prenatal exposure of these individuals to ionizing radiation. (author)

  10. Biomarkers of genetic damage in human populations exposed to pesticides

    International Nuclear Information System (INIS)

    Aiassa, Delia; Manas, Fernando; Bosch, Beatriz; Gentile, Natalia; Bernardi, Natali; Gorla, Nora

    2012-01-01

    The effect of pesticides on human, animal and environmental health has been cause of concern in the scientific community for a long time. Numerous studies have reported that pesticides are not harmless and that their use can lead to harmful biological effects in the medium and long term, in exposed human and animals, and their offspring. The importance of early detection of genetic damage is that it allows us to take the necessary measures to reduce or eliminate the exposure to the deleterious agent when damage is still reversible, and thus to prevent and to diminish the risk of developing tumors or other alterations. In this paper we reviewed the main concepts in the field, the usefulness of genotoxicity studies and we compiled studies performed during the last twenty years on genetic monitoring of people occupationally exposed to pesticides. we think that genotoxicity tests, including that include chromosomal aberrations, micronucleus, sister chromatid exchanges and comet assays, should be considered as essential tools in the implementation of complete medical supervision for people exposed to potential environmental pollutants, particularly for those living in the same place as others who were others have already developed some type of malignancy. This action is particularly important at early stages to prevent the occurrence of tumors, especially from environmental origins.

  11. Monitoring system for gamma radiation of porch type for vehicles

    International Nuclear Information System (INIS)

    Vazquez C, R.M.; Molina, G.; Gutierrez O, E.; Ramirez J, F.J.; Garcia H, J.M.; Aguilar B, M.A.; Vilchis P, A.E.; Cruz E, P.; Torres B, M.A.

    2005-01-01

    A monitoring system of gamma radiation for vehicles of the porch type developed in the ININ is presented. This system carries out the radiological monitoring of the vehicles in continuous form, detecting the bottom radiological environment and the presence of nuclear material transported in vehicles. The vehicles are monitored while they pass to low speed through the porch. The detectors are plastic scintillators of great volume that allow high sensibility detection. The arrangement of detecting is interconnected in net, and the data are concentrated on a personal computer whose interface man-machine can be accessed from any personal computer connected to Internet. The system monitoring in real time with options of sampling times from 50 ms configurable up to 500 ms. (Author)

  12. 21 CFR 880.2420 - Electronic monitor for gravity flow infusion systems.

    Science.gov (United States)

    2010-04-01

    ... and Personal Use Monitoring Devices § 880.2420 Electronic monitor for gravity flow infusion systems. (a) Identification. An electronic monitor for gravity flow infusion systems is a device used to... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electronic monitor for gravity flow infusion...

  13. Systemic arterial hypertension in patients exposed to Cesium-137 in Goiânia-GO: prevalence study

    International Nuclear Information System (INIS)

    Rodrigues, José Victor Rabelo; Pinto, Murillo Macêdo; Figueredo, Roberto Miller Pires; Lima, Helen de; Sacchetim, Sylvana de Castro; Souto, Rafael

    2017-01-01

    Background: Systemic Arterial Hypertension (SAH) in the Brazilian population, in populations not exposed to Césium-137, presents a prevalence of 28% nationwide. However, in the group of radioactivity victims, these values are unknown. Objective: To analyze the prevalence of hypertension in patients exposed to Cesium-137 in Goiânia, enrolled in the Sistema de Monitoramento dos Radioacidentados (SISRAD) (Radioactivity Victims Monitoring System) of the Centro de Assistência aos Radioacidentados (C.A.R.A) (Assistance Center for Radioactivity Victims). Methods: This is a descriptive, observational cross-sectional epidemiological study carried out in Goiânia-Goiás, from August 2013 to October 2014, with a group of patients enrolled in the Sistema de Monitoramento dos Radioacidentados (SISRAD) of the Centro de Assistência a Radioacidentados (C.A.R.A.). A total of 102 radioactive patients were divided into two groups: group 1 with 40 and group 2 with 62 participants. A field survey was conducted with a closed and semi-structured questionnaire in which the following contexts were addressed: sociodemographic profile, life habits and personal background. A database was created using the Google Forms application from the Google Web technologies company. The duly collected and stored data were imported and analyzed in the statistical software SPSS, version 21. Results: The prevalence of SAH reached a total of 25% (12 individuals) of the 48 interviewees, 50% of women (24) and 50% of men (24), of which 22.9% (11) of the radioactivity victims revealed to be smokers. Conclusion: The prevalence of SAH in the radioactivity victims population is similar to that of the population in general. (author)

  14. Systemic arterial hypertension in patients exposed to Cesium-137 in Goiânia-GO: prevalence study

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, José Victor Rabelo; Pinto, Murillo Macêdo; Figueredo, Roberto Miller Pires; Lima, Helen de; Sacchetim, Sylvana de Castro, E-mail: murillo_bb@hotmail.com [Centro Universitário de Anápolis (UniEVANGÉLICA), Goiania, GO (Brazil); Souto, Rafael [Secretaria da Saúde do Estado de Goiás, GO (Brazil)

    2017-06-15

    Background: Systemic Arterial Hypertension (SAH) in the Brazilian population, in populations not exposed to Césium-137, presents a prevalence of 28% nationwide. However, in the group of radioactivity victims, these values are unknown. Objective: To analyze the prevalence of hypertension in patients exposed to Cesium-137 in Goiânia, enrolled in the Sistema de Monitoramento dos Radioacidentados (SISRAD) (Radioactivity Victims Monitoring System) of the Centro de Assistência aos Radioacidentados (C.A.R.A) (Assistance Center for Radioactivity Victims). Methods: This is a descriptive, observational cross-sectional epidemiological study carried out in Goiânia-Goiás, from August 2013 to October 2014, with a group of patients enrolled in the Sistema de Monitoramento dos Radioacidentados (SISRAD) of the Centro de Assistência a Radioacidentados (C.A.R.A.). A total of 102 radioactive patients were divided into two groups: group 1 with 40 and group 2 with 62 participants. A field survey was conducted with a closed and semi-structured questionnaire in which the following contexts were addressed: sociodemographic profile, life habits and personal background. A database was created using the Google Forms application from the Google Web technologies company. The duly collected and stored data were imported and analyzed in the statistical software SPSS, version 21. Results: The prevalence of SAH reached a total of 25% (12 individuals) of the 48 interviewees, 50% of women (24) and 50% of men (24), of which 22.9% (11) of the radioactivity victims revealed to be smokers. Conclusion: The prevalence of SAH in the radioactivity victims population is similar to that of the population in general. (author)

  15. Manual on environmental monitoring in normal operation

    International Nuclear Information System (INIS)

    1966-01-01

    Many establishments handling radioactive materials produce, and to some extent also discharge, radioactive waste as part of their normal operation. The radiation doses to which members of the public may be exposed during such operation must remain below the stipulated level. The purpose of this manual is to provide technical guidance for setting up programmes of routine environmental monitoring in the vicinity of nuclear establishment. The annex gives five examples of routine environmental monitoring programmes currently in use: these have been indexed separately.

  16. Applied internal dosimetry staff exposed to Uranium

    International Nuclear Information System (INIS)

    Trotta, Marisa V.; Arguelles, Maria G.

    2009-01-01

    Dosimetric calculations are performed in order to estimate the quantity of a radionuclide that is incorporated by a worker. Urine determinations of activity and mass of uranium are made in the laboratory of Personal and Area Dosimetry. The paper presents reference values concerning the activity excreted in urine due to the incorporation of uranium compounds. The compounds analyzed are natural uranium and uranium enriched to 20 %, both soluble and insoluble. According to the limits allowed for the incorporation of uranium compounds of Type F and M, we verify that the times of monitoring and the detection limits of the equipment used to determine the activity are appropriate. On the other hand, the S-type compounds determination in urine is useful in cases of accidental incorporations (above the ALI) as a first and quick estimate; MDA (0.017 Bq / L) does not allow detection in routine monitoring; measurement in lungs, and faeces should be included. (author)

  17. Non-invasive, home-based electroencephalography hypoglycaemia warning system for personal monitoring using skin surface electrodes: a single-case feasibility study.

    Science.gov (United States)

    Clewett, Christopher J; Langley, Phillip; Bateson, Anthony D; Asghar, Aziz; Wilkinson, Antony J

    2016-03-01

    Hypoglycaemia unawareness is a common condition associated with increased risk of severe hypoglycaemia. The purpose of the authors' study was to develop a simple to use, home-based and non-invasive hypoglycaemia warning system based on electroencephalography (EEG), and to demonstrate its use in a single-case feasibility study. A participant with type 1 diabetes forms a single-person case study where blood sugar levels and EEG were recorded. EEG was recorded using skin surface electrodes placed behind the ear located within the T3 region by the participant in the home. EEG was analysed retrospectively to develop an algorithm which would trigger a warning if EEG changes associated with hypoglycaemia onset were detected. All hypoglycaemia events were detected by the EEG hypoglycaemia warning algorithm. Warnings were triggered with blood glucose concentration levels at or below 4.2 mmol/l in this participant and no warnings were issued when in euglycaemia. The feasibility of a non-invasive EEG-based hypoglycaemia warning system for personal monitoring in the home has been demonstrated in a single case study. The results suggest that further studies are warranted to evaluate the system prospectively in a larger group of participants.

  18. Personalized stress management : enabling stress monitoring with LifelogExplorer

    NARCIS (Netherlands)

    Kocielnik, R.D.; Sidorova, N.

    2015-01-01

    Stress is one of the major triggers for many diseases. Improving stress balance is therefore an important prevention step. With advances in wearable sensors, it becomes possible to continuously monitor and analyse user’s behavior and arousal in an unobtrusive way. In this paper, we report on a case

  19. Off-site environmental monitoring report: radiation monitoring around United States nuclear test areas, calendar year 1984

    International Nuclear Information System (INIS)

    Potter, G.D.; Black, S.C.; Grossman, R.F.; Patzer, R.G.; Smith, D.D.

    1985-04-01

    This report covers the routine radiation monitoring activities conducted by the Environmental Monitoring Systems Laboratory-Las Vegas in areas which may be affected by nuclear testing programs of the Department of Energy. This monitoring is conducted to document compliance with standards, to identify trends in environmental radiation, and to provide such information to the public. It summarizes these activities for calendar year 1984. No radioactivity attributable to NTS activities was detectable offsite by the monitoring networks. Using recorded wind data and Pasquill stability categories, atmospheric dispersion calculations based on reported radionuclides releases yield an estimated dose of 1 x 10 -3 person-rem to the population within 80 km of the Nevada Test Site during 1983. World-wide fallout of Kr-85, Sr-90, Cs-137, and Pu-239 detected by the monitoring networks would cause maximum exposure to an individual of less than 0.6 mrem per year. Plutonium in air was still detectable along with krypton-85, which continued its gradual increase, as has been reported previously. Cesium and strontium in air were near their detection limits. An occasional net exposure to offsite residents has been detected by the TLD network. On investigation, the cause of such net exposures has been due to personal habits or occupational activities, not to NTS activities. 32 refs., 36 figs., 27 tabs

  20. Evaluation of radiation protection educational level of professional exposed workers

    International Nuclear Information System (INIS)

    Marinkovic, O.; Krstev, S.; Jovanovic, S.

    2006-01-01

    Full text: Serbia and Montenegro legislation concerning with radiation protection was upgrading after publication ICRP- 60 and B.S.S., No.115. Present Law on the Protection against Ionizing Radiation is in force from 1996. Among quite new issues in radiation protection regulations there was article relate to obligatory refresher training. Due to adverse political and economic situation through many years radiation protection regulations were not fulfill completely. The aim of this investigation was to get real view to education level of professional exposed workers. In Serbia and Montenegro the most of ionizing radiation sources are in medical use and the most exposed workers are radiographers and radiologists. The test was passed by 200 radiographers and 50 radiologists. Main groups of questions were: Radiation protection and safety; difference between safety and security; legislation: law and regulations; incidents, accidents and operational failures: recording, learning. Usually, knowledge from school pales. New quantities (as ambient and personal dose equivalent) are mostly unknown. It is easier to understand the real difference between safety and security than to understand linguistic differences. Discussing regulations workers are more interesting in syndicate regulations than radiation protection ones. Operational failures and incidents are hidden. Better to say: nobody dare to speak about them. The results imposed conclusion that regulatory body has to pay more attention to upraise safety culture and radiation protection education level of professional exposed workers. (authors)

  1. Development and application of non-invasive biomarkers for carcinogen-DNA adduct analysis in occupationally exposed populations.

    Science.gov (United States)

    Talaska, G; Cudnik, J; Jaeger, M; Rothman, N; Hayes, R; Bhatnagar, V J; Kayshup, S J

    1996-07-17

    Biological monitoring of exposures to carcinogenic compounds in the workplace can be a valuable adjunct to environmental sampling and occupational medicine. Carcinogen-DNA adduct analysis has promise as a biomarker of effective dose if target organ samples can be obtained non-invasively. We have developed non-invasive techniques using exfoliated urothelial and bronchial cells collected in urine and sputum, respectively. First morning urine samples were collected from 33 workers exposed to benzidine or benzidine-based dyes and controls matched for age, education, and smoking status. Sufficient DNA for 32P-postlabelling analysis was obtained from every sample. Mean levels of a specific DNA adduct (which co-chromatographed with standard characterized by MS) were elevated significantly in the benzidine-exposed workers relative to controls. In addition, workers exposed to benzidine had higher adduct levels than those exposed to benzidine-based dyes. This study demonstrates the usefulness of these non-invasive techniques for exposure/effect assessment. To be useful in occupational studies, biomarkers must also be sensitive to exposure interventions. We have conducted topical application studies of used gasoline engine oils in mice and found that the levels of carcinogen-DNA adducts in skin and lung can be significantly lowered if skin cleaning is conducted in a timely manner. The combination of useful, non-invasive techniques to monitor exposure and effect and industrial hygiene interventions can be used to detect and prevent exposures to a wide range of carcinogens including those found in used gasoline engine oils and jet exhausts.

  2. Study of External Radiation Expose Dose on Hands of Nuclear Medicine Workers

    International Nuclear Information System (INIS)

    Park, Jun Chul; Pyo, Sung Jae

    2012-01-01

    management regulations, and take actions to maximally reduce locally exposed dose to hands monitoring with ring TLD.

  3. Personality traits and energy conservation

    International Nuclear Information System (INIS)

    Shen, Meng; Cui, Qingbin; Fu, Liping

    2015-01-01

    As a cost-effective solution to energy conservation, behavior based method focuses on changing people's behavior through normative feedback for energy efficiency. While the application of behavior-based method is promising, the challenge exists to achieve efficiently sustainable behavioral change. Based on multi-period observation of energy behavior at the Joint Base Andrews in Maryland, this paper presents a model-based approach aimed to improve the nationally popular and deep-seated benchmark setting strategy for normative feedback used in home energy reports. The improved approach has its merits of countering the undesirable boomerang effect and enhancing the effectiveness of normative feedback targeting different personalities. By introducing a modified opinion dynamics model, this paper simulates the process of energy behavior change and therefore identifies the driver and elementary rules of behavioral change. In particular, the paper defines various behavioral zones in accordance with people's personality and proposes a new customized energy reporting mechanism that maps normative benchmark to personality trait. The new energy reporting policy has strong industrial implication for promoting behavior-based method towards a sustained energy conservation movement. -- Highlights: •We explore the personality driving resident behavior change under peer pressure. •We map the distribution of behavior clusters driven by personality and benchmarks. •The model is tested using data from an experiment conducted in Maryland, U.S. •The population exposed to normative feedback can be divided into six categories. •A personality trait-based home energy reporting mechanism is proposed

  4. The VICKSI monitor interlock system

    International Nuclear Information System (INIS)

    Borchardt, D.; Kluppak, B.

    1983-01-01

    Dose rate equivalents are monitored separately for all working areas and evaluated by a central unit. The accelerator is shut off automatically if the maximum permissible concentrations given in the Radiation Protection Ordinance are exceeded and if persons are endangered. However, the experimenter may, on his own responsibility, define certain areas as 'vacated' (no staff members inside). Operation can then proceed as desired. Entry of persons into these areas is checked by the central computer. (orig./HP) [de

  5. Design of smart neonatal health monitoring system using SMCC.

    Science.gov (United States)

    De, Debashis; Mukherjee, Anwesha; Sau, Arkaprabha; Bhakta, Ishita

    2017-02-01

    Automated health monitoring and alert system development is a demanding research area today. Most of the currently available monitoring and controlling medical devices are wired which limits freeness of working environment. Wireless sensor network (WSN) is a better alternative in such an environment. Neonatal intensive care unit is used to take care of sick and premature neonates. Hypothermia is an independent risk factor for neonatal mortality and morbidity. To prevent it an automated monitoring system is required. In this Letter, an automated neonatal health monitoring system is designed using sensor mobile cloud computing (SMCC). SMCC is based on WSN and MCC. In the authors' system temperature sensor, acceleration sensor and heart rate measurement sensor are used to monitor body temperature, acceleration due to body movement and heart rate of neonates. The sensor data are stored inside the cloud. The health person continuously monitors and accesses these data through the mobile device using an Android Application for neonatal monitoring. When an abnormal situation arises, an alert is generated in the mobile device of the health person. By alerting health professional using such an automated system, early care is provided to the affected babies and the probability of recovery is increased.

  6. The potential risk of personal stereo players

    DEFF Research Database (Denmark)

    Hammershøi, Dorte; Ordoñez, Rodrigo Pizarro; Reuter, Karen

    2010-01-01

    The technological development within personal stereo systems,such as MP3 players, e. g. iPods, has changed music listening habits from home entertainment to everyday and everywhere use. The technology has developed considerably, since the introduction of cassette players and CD walkmen. High......-level low-distortion music is produced by minimal devices which can play for long periods. In this paper, the existing literature on effects of personal stereo systems is reviewed, incl. studies of exposure levels, and effects on hearing. Generally, it is found that the levels being used are of concern......, which in one study is demonstrated to relate to the specific use in situations with high levels of background noise. Another study demonstrates that the effect of using personal stereo is comparable to that of being exposed to noise in industry. The results are discussed in view of the measurement...

  7. Adequacy of individual monitoring of external exposure at the workplace

    International Nuclear Information System (INIS)

    Rannou, A.

    2006-01-01

    Individual monitoring of workers exposed to external radiations must fulfill technical, regulatory and organizational requirements. The external dosimetry should be adapted to the workplace. The relevant dosimetric techniques have to be chosen upon the workplace study that conditions both the categorization of exposed workers and classification of areas. Solutions exist which are satisfactory for the most situations. However, rational solutions still have to be found for a few specific situations. (author)

  8. Eryptosis in lead-exposed workers

    International Nuclear Information System (INIS)

    Aguilar-Dorado, Itzel-Citlalli; Hernández, Gerardo; Quintanar-Escorza, Martha-Angelica; Maldonado-Vega, María; Rosas-Flores, Margarita; Calderón-Salinas, José-Víctor

    2014-01-01

    Eryptosis is a physiological phenomenon in which old and damaged erythrocytes are removed from circulation. Erythrocytes incubated with lead have exhibited major eryptosis. In the present work we found evidence of high levels of eryptosis in lead exposed workers possibly via oxidation. Blood samples were taken from 40 male workers exposed to lead (mean blood lead concentration 64.8 μg/dl) and non-exposed workers (4.2 μg/dl). The exposure to lead produced an intoxication characterized by 88.3% less δ-aminolevulinic acid dehydratase (δALAD) activity in lead exposed workers with respect to non-lead exposed workers. An increment of oxidation in lead exposed workers was characterized by 2.4 times higher thiobarbituric acid-reactive substance (TBARS) concentration and 32.8% lower reduced/oxidized glutathione (GSH/GSSG) ratio. Oxidative stress in erythrocytes of lead exposed workers is expressed in 192% higher free calcium concentration [Ca 2+ ] i and 1.6 times higher μ-calpain activity with respect to non-lead exposed workers. The adenosine triphosphate (ATP) concentration was not significantly different between the two worker groups. No externalization of phosphatidylserine (PS) was found in non-lead exposed workers (< 0.1%), but lead exposed workers showed 2.82% externalization. Lead intoxication induces eryptosis possibly through a molecular pathway that includes oxidation, depletion of reduced glutathione (GSH), increment of [Ca 2+ ], μ-calpain activation and externalization of PS in erythrocytes. Identifying molecular signals that induce eryptosis in lead intoxication is necessary to understand its physiopathology and chronic complications. - Graphical abstract: Fig. 1. (A) Blood lead concentration (PbB) and (B) phosphatidylserine externalization on erythrocyte membranes of non-lead exposed (□) and lead exposed workers (■). Values are mean ± SD. *Significantly different (P < 0.001). - Highlights: • Erythrocytes of lead exposed workers showed higher PS

  9. Eryptosis in lead-exposed workers

    Energy Technology Data Exchange (ETDEWEB)

    Aguilar-Dorado, Itzel-Citlalli [Biochemistry Department, Centro de Investigación y Estudios Avanzados IPN, México, DF (Mexico); Hernández, Gerardo [Section of Methodology of Science, Centro de Investigación y Estudios Avanzados IPN, México, DF (Mexico); Quintanar-Escorza, Martha-Angelica [Faculty of Medicine, UJED, Durango, DGO (Mexico); Maldonado-Vega, María [CIATEC, León, GTO (Mexico); Rosas-Flores, Margarita [Biochemistry Department, Centro de Investigación y Estudios Avanzados IPN, México, DF (Mexico); Calderón-Salinas, José-Víctor, E-mail: jcalder@cinvestav.mx [Biochemistry Department, Centro de Investigación y Estudios Avanzados IPN, México, DF (Mexico)

    2014-12-01

    Eryptosis is a physiological phenomenon in which old and damaged erythrocytes are removed from circulation. Erythrocytes incubated with lead have exhibited major eryptosis. In the present work we found evidence of high levels of eryptosis in lead exposed workers possibly via oxidation. Blood samples were taken from 40 male workers exposed to lead (mean blood lead concentration 64.8 μg/dl) and non-exposed workers (4.2 μg/dl). The exposure to lead produced an intoxication characterized by 88.3% less δ-aminolevulinic acid dehydratase (δALAD) activity in lead exposed workers with respect to non-lead exposed workers. An increment of oxidation in lead exposed workers was characterized by 2.4 times higher thiobarbituric acid-reactive substance (TBARS) concentration and 32.8% lower reduced/oxidized glutathione (GSH/GSSG) ratio. Oxidative stress in erythrocytes of lead exposed workers is expressed in 192% higher free calcium concentration [Ca{sup 2+}]{sub i} and 1.6 times higher μ-calpain activity with respect to non-lead exposed workers. The adenosine triphosphate (ATP) concentration was not significantly different between the two worker groups. No externalization of phosphatidylserine (PS) was found in non-lead exposed workers (< 0.1%), but lead exposed workers showed 2.82% externalization. Lead intoxication induces eryptosis possibly through a molecular pathway that includes oxidation, depletion of reduced glutathione (GSH), increment of [Ca{sup 2+}], μ-calpain activation and externalization of PS in erythrocytes. Identifying molecular signals that induce eryptosis in lead intoxication is necessary to understand its physiopathology and chronic complications. - Graphical abstract: Fig. 1. (A) Blood lead concentration (PbB) and (B) phosphatidylserine externalization on erythrocyte membranes of non-lead exposed (□) and lead exposed workers (■). Values are mean ± SD. *Significantly different (P < 0.001). - Highlights: • Erythrocytes of lead exposed workers

  10. Occupational radiation exposure in Germany in 2006. Report of the radiation protection register

    International Nuclear Information System (INIS)

    Frasch, G.; Fritzsche, E.; Kammerer, L.; Karofsky, R.; Spiesl, J.; Stegemann, R.

    2008-06-01

    In Germany, persons occupationally exposed to radiation are monitored by several official dosimetric services who transmit their records about individual radiation doses to the Radiation Protection Register of the Federal Office for Radiation Protection (BfS). The number of dose recordings reported to the Radiation Protection Register has annually increased to more than three million records per year and thus accumulated to more than 34 million dose records at the end of 2006. The purpose of the Radiation Protection Register is to supervise the keeping of the dose limits by each radiation worker and to monitor the compliance with the radiation protection principle ''optimisation'' by performing detailed annual statistical analyses of the monitored persons and their radiation exposure. Amongst others, the annual report of the Radiation Protection Register provides information about status and development of occupational radiation exposure in Germany. In 2006, about 312,000 workers were monitored with dosimeters for occupational radiation exposure. About 18 % of the monitored persons received a measurable personal dose. The average annual dose of these exposed workers was 0.75 mSv. This value is the lowest average annual dose since dose monitoring for occupational worker was introduced. It remains below the dose limit of 1 mSv for the general public and amounts only 4 % of the annual dose limit of 20 mSv for radiation workers. Since 2003 aircraft crew personnel is subject to dose monitoring if it is employed in accordance with the German employment act and likely to receive an effective dose of at least 1 mSv per year from cosmic radiation during flight operation. This accounts for about 33.000 pilots and flight attendants. 45 airlines report the monthly accumulated dose values of their personnel via the Federal Office for Civil Aviation (''Luftfahrt-Bundesamt, LBA'') to the BfS. The collective dose of the aircraft crew personnel is 71 Person-Sv and thus

  11. Low CD4+ T-cell levels and B-cell apoptosis in vertically HIV-exposed noninfected children and adolescents.

    Science.gov (United States)

    Miyamoto, Maristela; Pessoa, Silvana D; Ono, Erika; Machado, Daisy M; Salomão, Reinaldo; Succi, Regina C de M; Pahwa, Savita; de Moraes-Pinto, Maria Isabel

    2010-12-01

    Lymphocyte subsets, activation markers and apoptosis were assessed in 20 HIV-exposed noninfected (ENI) children born to HIV-infected women who were or not exposed to antiretroviral (ARV) drugs during pregnancy and early infancy. ENI children and adolescents were aged 6-18 years and they were compared to 25 age-matched healthy non-HIV-exposed children and adolescents (Control). ENI individuals presented lower CD4(+) T cells/mm(3) than Control group (control: 1120.3 vs. ENI: 876.3; t-test, p = 0.030). ENI individuals had higher B-cell apoptosis than Control group (Control: 36.6%, ARV exposed: 82.3%, ARV nonexposed: 68.5%; Kruskal-Wallis, p ENI and in Control children and adolescents. Subtle long-term immune alterations might persist among ENI individuals, but the clinical consequences if any are unknown, and these children require continued monitoring.

  12. Environmental radioactivity monitoring around the Rokkasho reprocessing plant

    International Nuclear Information System (INIS)

    Sasaki, K.; Hareyama, H.; Takeishi, M.

    2009-01-01

    Japan Nuclear Fuel Limited has carried out environmental monitoring in order to check that the dose of radiation to which the public is exposed around the Rokkasho Reprocessing Plant (RRP) is much lower than the annual dose limit. The monitoring is mainly carried out according to 'the program decided by the Nuclear Safety Commission (NSC) of Japan' and 'the program decided by the Aomori Prefectural Government.' In this report, we present information on the monitoring according to the NSC program, that is the point of view of selection of the monitoring items for dose assessment, the point of view of the dose assessment from the monitoring results, etc. Also, we report on estimation of the effects from the facilities on the monitoring results obtained and dose assessment of the public during Active testing of RRP. (author)

  13. Procedures for operational monitoring of the environmental equivalent doses in cobalt therapy

    International Nuclear Information System (INIS)

    Perez Velasquez, Reytel; Gonzalez Lopez, Nadia; Perez Tamayo, Luis

    2009-01-01

    It took as its object of study environmental equivalent dose rates of field radiation they face radiophysicists technicians and medical physicists in the irradiation site of the radiation department of Lenin Hospital in Holguin, and the public that travels or remains in premises and areas surrounding the campus. It A review of national and international publications as well as technical documents to study the state of the art of the methodological existing monitoring of those dose rates and the valuation of impact in the context of an environmental management system. Since no detailed instructions and to perform the above-mentioned monitoring was proposed structure should contain a procedure to regulate the steps for this monitoring in the radiotherapy department of the Lenin Hospital Holguin, for which we studied the guidelines of NC ISO 14000 , and was conducted wide experiment whose led to: illustrate the level of doses required workers exposed occupationally exposed to radiation and the public compare these levels with natural radiation sources, assess the effectiveness of shielding the site of irradiation and the points of greatest risk within and outside the enclosure irradiation.Also assessed the impact it can have on the health of people exposed to such doses. Finally, we proposed a procedure for conducting subsequent monitoring and made recommendations to reduce levels radiation determined the lowest level reasonably achievable. (author)

  14. Investigating early stages of biocorrosion with XPS: AISI 304 stainless steel exposed to Burkholderia species

    Science.gov (United States)

    Johansson, Leena-Sisko; Saastamoinen, Tuomas

    1999-04-01

    We have investigated the interactions of an exopolymer-producing bacteria, Burkholderia sp. with polished AISI 304 stainless steel substrates using X-ray photoelectron spectroscopy (XPS). Steel coupons were exposed to the pure bacteria culture in a specially designed flowcell for 6 h during which the experiment was monitored in situ with an optical microscope. XPS results verified the formation of biofilm containing extracellular polymer on all the samples exposed to bacteria. Sputter results indicated that some ions needed for metabolic processes were trapped within the biofilm. Changes in the relative Fe concentration and Fe 2p peak shape indicated that also iron had accumulated into the biofilm.

  15. Conception of personal career as a self-realization project

    OpenAIRE

    Tarasova, Julija

    2017-01-01

    SUMMARY Conception of personal career as a self-realization project. Bachelor work. Relevance: Nowadays career is an important aspect in an individual’s life where the main author of the script, the director and creator is the person who takes responsibility for his/her own life. Modern career management is a life long process, which is more like a self monitored project based on self realisation. A successful career in project management is not only about an individual’s personal qualities, ...

  16. Monitoring and assessment of individual doses of occupationally exposed workers due to external radiation

    International Nuclear Information System (INIS)

    Kitaw, S. T.

    2015-05-01

    Exposure to external radiation occurs in many occupations. Any exposure to ionizing radiation has the tendency to change the biochemical make-up of the human body which may result in biological health effects of ionizing radiation. This study reviews the monitoring and assessment of external radiation doses in industrial radiography using thermoluminescence and direct reading dosimeters. Poor handling procedures such as inadequate engineering control of equipment, safety culture, management, and inadequate assessment and monitoring of doses are the causes of most of the reported cases of exposure to external radiation in industrial radiography. Occupational exposure data in industrial radiography from UNSCEAR report 2008 was discussed and recommendations were made to regulatory authorities, operating organizations and radiographers. (au)

  17. Quality assurance for multileaf collimator with radiographic film exposed by slit beam

    International Nuclear Information System (INIS)

    Ma Jinli; Jiang Guoliang; Fu Xiaolong; Liao Yuan; Wu Kailiang; Zhou Lijun

    2004-01-01

    Objective: To evaluate the role of Kodak X-OMAT-V film exposed by slit beam in the check of various leaf positions of multileaf collimator(MLC), and to check the status of Varian 26 leaf pairs MLC in the Department of Radiation Oncology in Shanghai Cancer Hospital affiliated to Fudan University. Methods: At first, some position errors of different sizes were produced for different leaves so as to determine the minimal leaf position error that could be seen on film. Then, exposure conditions including the exposure dose and source to film distance were changed to find the optimal one. Finally, a Kodak X-OMAT-V film was exposed with a leaf sequence file which was designated randomly by a physicist with leaf position errors of different sizes. After the film was developed, two doctors and two physicists were invited to observe, on blind basis, in order to determine the sensitivity and specificity of the film in the check of leaf positions. Ultimately, leaf positions of the Varian 26 leaf pairs MLC were checked, in which way, the leaf motor status and the carriage stability were checked indirectly. Results: Leaf position errors no less than 0.2 mm could be found using Kodak X-OMAT-V film under the following conditions: source to film distance 100 cm, exposure dose 25 MU, which had been considered as the optimal exposure conditions. The sensitivity and specificity of this method were 73.4% and 96.4%. Any MLC leaf position errors more than 0.2 mm could not be detected. Thus, it was deemed that all leaf motors of the Varian 26 leaf pairs MLC were well in gear and the carriages were stable. Conclusions: MLC leaf position errors can be detected by Kodak X-OMAT-V film exposed by slit beam with high accuracy, but the ability to find leaf position errors with the naked eye may vary from person to person. It is proposed that the Kodak X-OMAT-V film exposed by slit beam be used to check the MLC leaf positions, i. e. the leaf motor status and carriage stability, at regular

  18. Towards a Personal Health Record System for the Assesment and Monitoring of Sedentary Behavior in Indoor Locations.

    Science.gov (United States)

    Ceron, Jesus D; Lopez, Diego M

    2016-01-01

    Sedentary behavior has been associated to the development of noncommunicable diseases (NCD) such as cardiovascular diseases (CVD), type 2 diabetes, and cancer. Accelerometers and inclinometers have been used to estimate sedentary behaviors, however a major limitation is that these devices do not provide contextual information such as the activity performed, e.g., TV viewing, sitting at work, driving, etc. The main objective of the thesis is to propose and evaluate a Personal Health Record System to support the assessment and monitoring of sedentary behaviors. Until now, we have implemented a system, which identifies individual's sedentary behaviors and location based on accelerometer data obtained from a smartwatch, and symbolic location data obtained from Bluetooth beacons. The system infers sedentary behaviors by means of a supervised Machine Learning Classifier. The precision in the classification of the six studied sedentary behaviors exceeded 90%, being the Random Forest algorithm the most precise. The proposed system allows the recognition of specific sedentary behaviors and their location with very high precision.

  19. The influence of impression management scales on the Personality Assessment Inventory in the epilepsy monitoring unit.

    Science.gov (United States)

    Purdom, Catherine L; Kirlin, Kristin A; Hoerth, Matthew T; Noe, Katherine H; Drazkowski, Joseph F; Sirven, Joseph I; Locke, Dona E C

    2012-12-01

    The Somatic Complaints scale (SOM) and Conversion subscale (SOM-C) of the Personality Assessment Inventory perform best in classifying psychogenic non-epileptic seizures (PNES) from epileptic seizures (ES); however, the impact of positive impression management (PIM) and negative impression management (NIM) scales on SOM and SOM-C classification has not been examined. We studied 187 patients from an epilepsy monitoring unit with confirmed PNES or ES. On SOM, the best cut score was 72.5 T when PIM was elevated and 69.5 T when there was no bias. On SOM-C, when PIM was elevated, the best cut score was 67.5 T and 76.5 T when there was no bias. Negative impression management elevations (n=9) were too infrequent to analyze separately. Despite similarities in classification accuracy, there were differences in sensitivity and specificity with and without PIM, impacting positive and negative predictive values. The presence of PIM bias generally increases positive predictive power of SOM and SOM-C but decreases negative predictive power. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Monitoring of persons with injuries with incorporated radioactive material

    International Nuclear Information System (INIS)

    Lopes, A.G.; Tauhata, L.

    2017-01-01

    The monitoring of victims with injuries with incorporated radioactive material can be performed with portable detectors in initial evaluations, with unshielded measurements, collimation, often with the ignorance of the radionuclide, and also, in the posterior medical follow-up with whole-body detectors and HPGe, in measurements of body or urine activity in periodic measurements. Dosimetry in these situations is done using appropriate models, which surpass those of orthodox internal dosimetry, the biokinetic model described in the 2006 NCRP, such as the AIDE models, and the one developed by Deepesh for the 241 Am. Using tissue-equivalent material, measurements were made with portable detectors to obtain the values of the total attenuation coefficient for the 241 Am radiation and compared to the NIST tables. Measurements were also made with the fixed detectors for certification of the measurement procedure. The percentage deviations obtained in relation to the theoretical ones were: PRD (55%) and IdentiFINDER2 (72%). First-aid monitoring measurements may present great uncertainties and differences of accuracy, but are important data to guide the medical treatment of the victims of accidents