  1. HEART ELECTRICAL AXIS Α ANGLE VALUES DISTRIBUTION IN PATIENTS, UNDERGOING PERMANENT PACEMAKER IMPLANTATION

    Directory of Open Access Journals (Sweden)

    O. S. Voronenko

    2016-06-01

    Full Text Available 52 patients (24 male and 28 female aged 71 ± 8 years, underwent permanent pacemaker implantation were included in the study. Analysis of heart electrical axis (HEA α angle values distribution was carried out in three dimensions in patience before and after pacemaker (PM implantation. The data processed in Microsoft Excel with calculation of the average and it’s standard deviation. Significance of differences in data before and after PM implantation was assessed using Friedman ANOVA test and Kendall concordance coefficient. It was found, that α angle values distribution in patients with implanted PM is transformed from a unimodal to bimodal on the permanent cardiac pacing background. It’s assumed, that α angle changes resulting due to right ventricular electrode positioning options during PM implantation. Clarification of the nature of this change requires a special study.

  2. Effects of Appropriate Prolonged Sacral Neuromodulation Testing in Improving Implantation Rate of a Permanent Implantable Pulse Generator in Patients with Refractory Lower Urinary Tract Dysfunctions in Mainland China

    Directory of Open Access Journals (Sweden)

    Peng Zhang

    2017-01-01

    Results: Among 51 patients receiving SNM therapy, 19 patients (mean age 45.0 ± 16.9 years had poor Stage I test results, and on an average, the electrode was removed 27.4 ± 9.6 days after the surgery. In one patient, the electrode was removed within 2 weeks; when the remaining 18 patients were questioned 2 weeks after testing, none of the patients wanted to terminate the test, and all the 18 patients desired to prolong the testing time to further observe the treatment effect. The remaining 32 patients (mean age 46.7 ± 15.3 years received Stage II permanent implantation at 19.6 ± 10.4 days after the surgery. The overall Stage I–II conversion was 62.7% (32/51 in this study. Within 2 weeks after the surgery, only eight patients received Stage II permanent implantation, and the conversion rate was only 15.7% (8/51, which was much lower than the overall conversion rate of 62.7%. Nearly 84.4% (27/32 of the patients received Stage II implantation within 4 weeks. None of the patients had incision infections. In one patient, the entire system was removed 1 month after Stage II implantation due to pain in the implantation site. Conclusions: Appropriate extension of the Stage I testing time of an SNM-barbed electrode could significantly improve the Stage II permanent implantation rate in Chinese refractory LUTS patients; there were no wound infections, and the postoperative complication rate was low. This study recommended that Stage I period of SNM therapy should be 4 weeks according to safety and successful conversion rate.

  3. 21 CFR 870.3680 - Cardiovascular permanent or temporary pacemaker electrode.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiovascular permanent or temporary pacemaker... § 870.3680 Cardiovascular permanent or temporary pacemaker electrode. (a) Temporary pacemaker electrode—(1) Identification. A temporary pacemaker electrode is a device consisting of flexible insulated...

  4. The influence of cochlear implant electrode position on performance

    NARCIS (Netherlands)

    Marel, K.S. van der; Briaire, J.J.; Verbist, B.M.; Muurling, T.J.; Frijns, J.H.M.

    2015-01-01

    To study the relation between variables related to cochlear implant electrode position and speech perception performance scores in a large patient population.The study sample consisted of 203 patients implanted with a CII or HiRes90K implant with a HiFocus 1 or 1J electrode of Advanced Bionics.

  5. Permanent and temporary pacemaker implantation after orthotopic heart transplantation

    Directory of Open Access Journals (Sweden)

    Bacal Fernando

    2000-01-01

    Full Text Available PURPOSE:To determine the indication for and incidence and evolution of temporary and permanent pacemaker implantation in cardiac transplant recipients. METHODS: A retrospective review of 114 patients who underwent orthotopic heart transplantation InCor (Heart Institute USP BR between March 1985 and May 1993. We studied the incidence of and indication for temporary pacing, the relationship between pacing and rejection, the need for pemanent pacing and the clinical follow-up. RESULTS: Fourteen of 114 (12%heart transplant recipients required temporary pacing and 4 of 114 (3.5% patients required permanent pacing. The indication for temporary pacing was sinus node dysfunction in 11 patients (78.5% and atrioventricular (AV block in 3 patients (21.4%. The indication for permanent pacemaker implantation was sinus node dysfunction in 3 patients (75% and atrioventricular (AV block in 1 patient (25%. We observed rejection in 3 patients (21.4% who required temporary pacing and in 2 patients (50% who required permanent pacing. The previous use of amiodarone was observed in 10 patients (71.4% with temporary pacing. Seven of the 14 patients (50% died during follow-up. CONCLUSION: Sinus node dysfunction was the principal indication for temporary and permanent pacemaker implantation in cardiac transplant recipients. The need for pacing was related to worse prognosis after cardiac transplantation.

  6. Quality of life after permanent prostate implant

    International Nuclear Information System (INIS)

    Arterbery, V. Elayne; Frazier, Arthur; Dalmia, Praveen; Porter, Arthur

    1997-01-01

    Purpose: To report on the quality of life in patients who have received a permanent transperineal ultrasound guide prostate implant. There is increasing recognition that prostate cancer therapy impacts significantly on the patients ability to pursue relational, occupational and social interests. With the substantially expanded patient role in directing treatment for prostate cancer, the importance of examining quality of life outcomes in addition to survival has been underscored. Materials and Methods: 51 sequential patients with clinically localized prostate cancer who underwent permanent prostate implantation from September 1995 to October 1996 were evaluated. All patients were clinically staged as T1c or T2a and received implant with Iodine 125 or Palladium 103 as definitive treatment. Data was collected using the EORTC genitourinary group questionnaire and supplemental questions during an interview. Results: Urinary symptoms such as nocturia, frequency and dysuria were the most pronounced in the first two months after implant and then decreased in the majority of patients. The EORTC questionnaire was administered at 6 months and examined urinary quality, sexual quality and perception of symptoms. With regard to urinary quality, 17% had mild dysuria at 6 months and 40% noted that they urinated more frequently than pre implant. No patient had hematuria and 0 % were incontinent. 3% stated that they had occasional loss of minimal urine with severe urgency. Only 2% required intermittent self catheterization after implant secondary to obstructive symptoms. Over 90% were on an alpha blocker post implant for a minimum of 6 weeks. 0% reported psychological distress and 3% noted a disruption in social or family life. 15% experienced some fatigue and 10% noted a decreased functional status but only 1% a decreased role function. Additional questions addressed lifestyle and work issues. 100% would have an implant again as definitive treatment and 98% would recommend the

  7. Low permanent pacemaker rates following Lotus device implantation for transcatheter aortic valve replacement due to modified implantation protocol.

    Science.gov (United States)

    Krackhardt, Florian; Kherad, Behrouz; Krisper, Maximilian; Pieske, Burkert; Laule, Michael; Tschöpe, Carsten

    2017-01-01

    Conduction disturbances requiring permanent pacemaker implantation following transcatheter aortic valve replacement (TAVR) are a common problem. Pacemaker implantation rates after TAVR appear to be higher compared to conventional aortic valve replacement. The aim of this study was to analyze whether a high annulus implantation conveys the benefit of a decreased rate of permanent pacemaker implantation while being safe and successful according to Valve Academic Research Consortium 2 (VARC2)-criteria. A total of 23 patients with symptomatic severe aortic valve stenosis, an aortic annulus of 19-27 mm and at high risk for surgery were treated with the Lotus valve. In all patients the valve was implanted in a high annulus position via femoral access. The primary device performance endpoint was VARC2-defined device success after 30 days and the primary safety endpoint was the need for permanent pacemaker implantation. The mean age was 73.23 ± 7.65 years, 46% were female, 38% were New York Heart Association class III/IV at baseline. Thirty-day follow-up data were available for all patients. The VARC2-defined device success rate after 30 days was 22/23 (96%). 2/21 (10%) patients required a newly implanted pacemaker due to 3rd degree atrioventricular block. 25% of the patients developed a new left bundle branch block after valvuloplasty or device implantation. 21 of the 23 patients (96%) had no other signs of conduction disturbances after 30 days. The approach of the modified implantation technique of Lotus TAVR device was safe and effective. The incidence of need for a permanent pacemaker following TAVR could be significantly reduced due to adopted implantation protocol.

  8. Vestibular Function After Cochlear Implantation: A Comparison of Three Types of Electrodes.

    Science.gov (United States)

    Frodlund, Jonas; Harder, Henrik; Mäki-Torkko, Elina; Ledin, Torbjörn

    2016-12-01

    To investigate the vestibular function after cochlear implantation with different types of electrode arrays. Retrospective cohort study. Academic tertiary referral center. Forty three adults underwent first cochlear implantation. Three consecutive series of patients: Group 1 (n = 13) implanted with a precurved electrode, Group 2 (n = 15) implanted with a straight electrode, Group 3 (n = 15) implanted with a flexible electrode. Patient's vestibular functions were assessed with pre- and postoperative caloric testing using videonystagmography (VNG). The postoperative reduction of the maximum slow phase velocity (MSPV) in the implanted ear was evaluated. Medical charts were reviewed to evaluate the occurrence of late onset of postoperative vestibular symptoms. Mean reduction of MSPV was 7.6/s (standard deviation [SD] 8.0) in Group 1, 23.1/s (SD 16.6) in Group 2, and 0.1/s (SD 18.5) in Group 3. Significant difference was found between Group 1 and 2 (p < 0.030) and between Group 2 and 3 (p < 0.001). Group 2 showed a higher prevalence of late onset of clinical vertigo (28.6%) than Group 1 (7.7%) and 3 (6.7%). In this prospective study, significantly larger reductions of caloric responses were found in subjects implanted with a straight electrode compared with subjects implanted with a precurved or flexible electrode. These findings seem to correlate to a higher prevalence of postoperative vertigo.

  9. Clinical application of permanent implantation of iodine 125 seeds for osseous metastases

    International Nuclear Information System (INIS)

    Li Jinxin; Zhang Qizhou; Li Guoliang

    2010-01-01

    Objective: To evaluate the clinical efficacy of permanent implantation of iodine 125 seeds in the treatment of osseous metastases. Methods: Radioactive iodine 125 seeds were implanted permanently in 32 lesions of 25 patients with osseous metastases of different origins. The ostalgia-relieving degree and the imaging alterations of the osseous metastasis lesions were observed. Results: The effective pain-relieving rate was 92% caused by permanent implantation of iodine 125 seeds. Of al 1 the patients, 15 patients achieved complete response, 8 patients obtained partial response (PR), and 2 patients had no change. The pain grade was decreased significantly after the treatment (P 125 I seeds has a definite effect on tumor metastasis and caused minimal damage and few complications. It is worthy of popularization in clinic. (authors)

  10. Analysis of the radiobiology of ytterbium-169 and iodine-125 permanent brachytherapy implants

    Energy Technology Data Exchange (ETDEWEB)

    Lazarescu, G.R. [Windsor Regional Cancer Center, Ontario Cancer Treatment and Research Foundation, Windsor, Canada N8W 2X3 (Canada); Battista, J.J. [London Regional Cancer Center, Ontario Cancer Treatment and Research Foundation, Dept. of Oncology and Dept. of Medical Biophysics, University of Western Ontario, London, Canada N6A 4L6 (Canada)

    1997-09-01

    Recently, Yb-169 has been considered as a potential replacement for I-125 and Pd-103 in permanent implants. In spite of the uncertainties in the parameters necessary for an accurate radiobiological modelling, the linear quadratic model can be useful in the comparative evaluation of the radiotherapeutic merit of similar implants. In order to find out if a Yb-169 permanent implant can be made biologically 'equivalent' to an I-125 implant, we studied the dependence of local control on the tumour cell radiosensitivity and on the balance between the rate of tumour cell killing and tumour cell proliferation, for rapidly and slowly proliferating tumours. The extrapolated response dose (ERD) has been calculated for tumour and late reacting normal tissue for both types of implants and the possible biological restrictions due to the normal tissue tolerance have been discussed. Our theoretical analysis is consistent with the clinical results published for I-125 permanent implants in prostate tumours and meningiomas. It predicts that Yb-169, which has only recently been used in human tumours, can provide comparable tumour control for permanent implants in slowly proliferating tumours with an initial dose rate of 13 cGy h{sup -1}. Control might be extended to rapidly proliferating tumours by increasing the initial dose rate within a range consistent with an acceptable level of normal tissue late reaction. (author)

  11. Implantable electrode for recording nerve signals in awake animals

    Science.gov (United States)

    Ninomiya, I.; Yonezawa, Y.; Wilson, M. F.

    1976-01-01

    An implantable electrode assembly consisting of collagen and metallic electrodes was constructed to measure simultaneously neural signals from the intact nerve and bioelectrical noises in awake animals. Mechanical artifacts, due to bodily movement, were negligibly small. The impedance of the collagen electrodes, measured in awake cats 6-7 days after implantation surgery, ranged from 39.8-11.5 k ohms at a frequency range of 20-5 kHz. Aortic nerve activity and renal nerve activity, measured in awake conditions using the collagen electrode, showed grouped activity synchronous with the cardiac cycle. Results indicate that most of the renal nerve activity was from postganglionic sympathetic fibers and was inhibited by the baroceptor reflex in the same cardiac cycle.

  12. Permanent pace maker implantation through axillary vein approach

    International Nuclear Information System (INIS)

    Shah, B.; Hussain, C.; Awan, Z.A.

    2017-01-01

    Device implantation is an integral part of interventional cardiology particularly electrophysiology. In this study, we are going to share our experience of device implantation technique at electrophysiology department Hayatabad Medical Complex, Peshawar. Methods: the study was conducted from June 2011 to December 2015. Axillary vein was used to implant the devices but in some cases when this rout was not convenient due to any reason then subclavian vein was entered through the Seldinger technique. Fluoroscopy time was less than 10 minutes and total procedure time was not more than 45 minutes. Electric cautery was used only in two cases. Pressure dressing was used in a few cases. Results: Total numbers of permanent pacemakers (PPM) remain 800 during the study period. There were 450 single chamber pacemakers and 350 dual chambers pacemakers. No case of any major bleeding was documented and in very few cases there was mild ooze from the procedure site after the operation which was tackled with pressure dressing. Four cases of pneumothorax were noted during the study period and in three cases chest intubation were done and one patient was kept on conservative management. Patient were followed after one month of discharge from the hospital and then yearly. Eight cases of lead dislodgment were documented during the study period. Conclusion: Axillary vein approach for implantation of permanent pacemakers is a safe and less time-consuming technique. (author)

  13. Effects of ion implantation on the electrochemical characteristics of carbon electrodes

    International Nuclear Information System (INIS)

    Takahashi, Katsuo; Iwaki, Masaya

    1994-01-01

    Various carbon materials are important electrode materials for electrochemical field. By ion implantation, the surface layer reforming of carbon materials (mainly galssy carbon) was carried out, and the effect that it exerts to their electrode characteristics was investigated. As the results of the ion implantation of Li, N, O, K, Ti, Zn, Cd and others performed so far, it was found that mainly by the change of the surface layer to amorphous state, there were the effects of the lowering of base current and the lowering of electrode reaction rate, and it was known that the surface layers of carbon materials doped with various kinds of ions showed high chemical stability. The use of carbon materials as electrodes in electrochemistry is roughly divided into the electrodes for electrolytic industry and fuel cells for large current and those for the measurement in electrochemical reaction for small current. The structure of carbon materials and electrode characteristics, and the reforming effect by ion implantation are reported. (K.I.)

  14. Electrode selection for hearing preservation in cochlear implantation: A review of the evidence

    Directory of Open Access Journals (Sweden)

    Jason A. Brant

    2016-09-01

    Full Text Available Objective: To review and assess the ideal length of electrode in cochlear implant patients for hearing preservation. Methods: The English language literature was reviewed for studies including hearing preservation and speech understanding for electrodes of different lengths. Results: One prospective trial was found, and there were no studies that randomized patients into different length electrodes with an intent to preserve hearing. Eight studies total included multiple length electrodes and contained data regarding hearing preservation. Conclusions: Although there is some evidence that indicates that shorter electrodes may improve both short and long-term hearing preservation rates in cochlear implant patients, no study has directly compared implant length on hearing preservation in a similar patient population. A randomized trial of short and standard length electrodes for hearing preservation is warranted. In the interim, utilization of current electrodes measuring 20–25 mm could seem to be a prudent approach when seeking to preserve residual hearing without unduly compromising cochlear coverage. Keywords: Electrode, Length, Hearing preservation, Cochlear implantation

  15. Reevaluation of the indications for permanent pacemaker implantation after transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Bjerre Thygesen, Julie; Loh, Poay Huan; Cholteesupachai, Jiranut

    2014-01-01

    AIMS: Conduction abnormalities (CA) requiring permanent pacemaker (PPM) are a well-known complication after transcatheter aortic valve implantation (TAVI). This study aimed to determine the incidence of TAVI-related PPM and reevaluate the indications for PPM after the periprocedural period. METHO...

  16. A Novel Percutaneous Electrode Implant for Improving Robustness in Advanced Myoelectric Control

    Directory of Open Access Journals (Sweden)

    Janne M. Hahne

    2016-03-01

    Full Text Available Despite several decades of research, electrically powered hand and arm prostheses are still controlled with very simple algorithms that process the surface electromyogram (EMG of remnant muscles to achieve control of one prosthetic function at a time. More advanced machine learning methods have shown promising results under laboratory conditions. However, limited robustness has largely prevented the transfer of these laboratory advances to clinical applications. In this paper, we introduce a novel percutaneous EMG electrode to be implanted chronically with the aim of improving the reliability of EMG detection in myoelectric control. The proposed electrode requires a minimally invasive procedure for its implantation, similar to a cosmetic micro-dermal implant. Moreover, being percutaneous, it does not require power and data telemetry modules. Four of these electrodes were chronically implanted in the forearm of an able-bodied human volunteer for testing their characteristics. The implants showed significantly lower impedance and greater robustness against mechanical interference than traditional surface EMG electrodes used for myoelectric control. Moreover, the EMG signals detected by the proposed systems allowed more stable control performance across sessions in different days than that achieved with classic EMG electrodes. In conclusion, the proposed implants may be a promising interface for clinically available prostheses.

  17. Characteristics of electrode impedance and stimulation efficacy of a chronic cortical implant using novel annulus electrodes in rat motor cortex

    Science.gov (United States)

    Wang, Chun; Brunton, Emma; Haghgooie, Saman; Cassells, Kahli; Lowery, Arthur; Rajan, Ramesh

    2013-08-01

    Objective. Cortical neural prostheses with implanted electrode arrays have been used to restore compromised brain functions but concerns remain regarding their long-term stability and functional performance. Approach. Here we report changes in electrode impedance and stimulation thresholds for a custom-designed electrode array implanted in rat motor cortex for up to three months. Main Results. The array comprises four 2000 µm long electrodes with a large annular stimulating surface (7860-15700 µm2) displaced from the penetrating insulated tip. Compared to pre-implantation in vitro values there were three phases of impedance change: (1) an immediate large increase of impedance by an average of two-fold on implantation; (2) a period of continued impedance increase, albeit with considerable variability, which reached a peak at approximately four weeks post-implantation and remained high over the next two weeks; (3) finally, a period of 5-6 weeks when impedance stabilized at levels close to those seen immediately post-implantation. Impedance could often be temporarily decreased by applying brief trains of current stimulation, used to evoke motor output. The stimulation threshold to induce observable motor behaviour was generally between 75-100 µA, with charge density varying from 48-128 µC cm-2, consistent with the lower current density generated by electrodes with larger stimulating surface area. No systematic change in thresholds occurred over time, suggesting that device functionality was not compromised by the factors that caused changes in electrode impedance. Significance. The present results provide support for the use of annulus electrodes in future applications in cortical neural prostheses.

  18. Hearing Preservation Outcomes With a Mid-Scala Electrode in Cochlear Implantation.

    Science.gov (United States)

    Hunter, Jacob B; Gifford, René H; Wanna, George B; Labadie, Robert F; Bennett, Marc L; Haynes, David S; Rivas, Alejandro

    2016-03-01

    To evaluate hearing preservation (HP) outcomes in adult cochlear implant recipients with a mid-scala electrode. Tertiary academic center. Adult patients implanted with a mid-scala electrode between May 2013 and July 2015. Cochlear implantation. Age, sex, surgical approach, residual hearing changes post cochlear implantation, HP rates using different published classifications, and speech perception scores. Fifty ears for 47 patients (mean age, 58.2 yr; range, 23-86) were implanted with the electrode. Recognizing that not all patients were true HP candidates and/or underwent generally accepted HP surgical techniques, 39 ears had preoperative low-frequency hearing (audiometric threshold ≤ 85dB HL at 250Hz), 24 preserved acoustic hearing postoperatively (75.0%). Patients who had preserved acoustic hearing were implanted via round window (N = 18), extended round window (N = 4), or via cochleostomy (N = 2) approaches. Mean threshold elevation for low-frequency pure-tone average (125, 250, and 500  Hz) was 20.2  dB after surgery. 43.8% of patients had aidable low-frequency hearing at activation, 30.0% at 6-months postoperatively, and 30.8% 1-year postopera tively. Using a formula outlined by Skarzynski and colleagues, at 6-months postoperatively, 15.0% of patients had complete HP, whereas 40.0% had partial HP. At 1-year, these percentages decreased to 0% and 38.5%, respectively. Age, type of approach, and perioperative steroid use were not correlated with HP outcomes at activation and 6-months postoperatively (p > 0.05). The mid-scala electrode evaluated allows preservation of low-frequency hearing in patients undergoing cochlear implantation at rates and degrees of preservation close to other reports in the cochlear implant literature.

  19. Intracranial depth electrodes implantation in the era of image-guided surgery

    Directory of Open Access Journals (Sweden)

    Ricardo Silva Centeno

    2011-08-01

    Full Text Available The advent of modern image-guided surgery has revolutionized depth electrode implantation techniques. Stereoelectroencephalography (SEEG, introduced by Talairach in the 1950s, is an invasive method for three-dimensional analysis on the epileptogenic zone based on the technique of intracranial implantation of depth electrodes. The aim of this article is to discuss the principles of SEEG and their evolution from the Talairach era to the image-guided surgery of today, along with future prospects. Although the general principles of SEEG have remained intact over the years, the implantation of depth electrodes, i.e. the surgical technique that enables this method, has undergone tremendous evolution over the last three decades, due the advent of modern imaging techniques, computer systems and new stereotactic techniques. The use of robotic systems, the constant evolution of imaging and computing techniques and the use of depth electrodes together with microdialysis probes will open up enormous prospects for applying depth electrodes and SEEG both for investigative use and for therapeutic use. Brain stimulation of deep targets and the construction of "smart" electrodes may, in the near future, increase the need to use this method.

  20. Intracranial depth electrodes implantation in the era of image-guided surgery.

    Science.gov (United States)

    Centeno, Ricardo Silva; Yacubian, Elza Márcia Targas; Caboclo, Luis Otávio Sales Ferreira; Júnior, Henrique Carrete; Cavalheiro, Sérgio

    2011-08-01

    The advent of modern image-guided surgery has revolutionized depth electrode implantation techniques. Stereoelectroencephalography (SEEG), introduced by Talairach in the 1950s, is an invasive method for three-dimensional analysis on the epileptogenic zone based on the technique of intracranial implantation of depth electrodes. The aim of this article is to discuss the principles of SEEG and their evolution from the Talairach era to the image-guided surgery of today, along with future prospects. Although the general principles of SEEG have remained intact over the years, the implantation of depth electrodes, i.e. the surgical technique that enables this method, has undergone tremendous evolution over the last three decades, due the advent of modern imaging techniques, computer systems and new stereotactic techniques. The use of robotic systems, the constant evolution of imaging and computing techniques and the use of depth electrodes together with microdialysis probes will open up enormous prospects for applying depth electrodes and SEEG both for investigative use and for therapeutic use. Brain stimulation of deep targets and the construction of "smart" electrodes may, in the near future, increase the need to use this method.

  1. I-123 metaiodobenzylguanidine cardiac scintigraphy in patients with an implanted permanent pacemaker

    International Nuclear Information System (INIS)

    Nakata, Akio; Hirota, Satoshi; Tsuji, Hiroshi; Takazakura, Eisuke

    1995-01-01

    Tl scintigraphic abnormalities have been reported in patients with an implanted permanent pacemaker, but little is known about the MIBG scintigraphic findings in such patients. This study was performed to assess the MIBG scintigraphic findings in patients with an implanted permanent pacemaker, and to test the hypothesis that imaging characteristics of MIBG scintigraphy differ according to its mode. Twelve patients (4 men and 8 women, mean age: 72.4±9.5 years), who had undergone the implantation of a permanent pacemaker for bradyarrhythmias, underwent MIBG scintigraphy. The patients were divided into VVI pacemaker and DDD pacemaker groups. The tomograms were divided into nine segments and the MIBG defect in each segment scored on a scale ranging from 0 (normal uptake) to 3 (no uptake). Total MIBG defect scores were generated by summing the scores for the nine segments in each patient. MIBG scintigraphic abnormalities were found in ten of the twelve patients. The six patients with the VVI pacemaker manifested MIBG scintigraphic abnormalities. These MIBG scintigraphic abnormalities were observed in all segments, particularly in the posterior segments. The mean total defect score of the VVI group was higher than that of the DDD group (14.8±9.8 vs 3.0±3.5, respectively p<0.05). Therefore, we conclude that despite several limitations of the study, MIBG scintigraphic abnormalities occur in patients with implanted permanent pacemakers, and that such abnormalities are more prominent with the VVI than DDD pacemaker. (author)

  2. Mathematical modeling of chemotaxis and glial scarring around implanted electrodes

    International Nuclear Information System (INIS)

    Silchenko, Alexander N; Tass, Peter A

    2015-01-01

    It is well known that the implantation of electrodes for deep brain stimulation or microelectrode probes for the recording of neuronal activity is always accompanied by the response of the brain’s immune system leading to the formation of a glial scar around the implantation sites. The implantation of electrodes causes massive release of adenosine-5′-triphosphate (ATP) and different cytokines into the extracellular space and activates the microglia. The released ATP and the products of its hydrolysis, such as ADP and adenosine, become the main elements mediating chemotactic sensitivity and motility of microglial cells via subsequent activation of P2Y 2,12 as well as A3A/A2A adenosine receptors. The size and density of an insulating sheath around the electrode, formed by microglial cells, are important criteria for the optimization of the signal-to-noise ratio during microelectrode recordings or parameters of electrical current delivered to the brain tissue. Here, we study a purinergic signaling pathway underlying the chemotactic motion of microglia towards implanted electrodes as well as the possible impact of an anti-inflammatory coating consisting of the interleukin-1 receptor antagonist. We present a model describing the formation of a stable aggregate around the electrode due to the joint chemo-attractive action of ATP and ADP and the mixed influence of extracellular adenosine. The bioactive coating is modeled as a source of chemo-repellent located near the electrode surface. The obtained analytical and numerical results allowed us to reveal the dependences of size and spatial location of the insulating sheath on the amount of released ATP and estimate the impact of immune suppressive coating on the scarring process. (paper)

  3. Complications and results of subdural grid electrode implantation in epilepsy surgery.

    Science.gov (United States)

    Lee, W S; Lee, J K; Lee, S A; Kang, J K; Ko, T S

    2000-11-01

    We assessed the risk of delayed subdural hematoma and other complications associated with subdural grid implantation. Forty-nine patients underwent subdural grid implantation with/without subdural strips or depth electrodes from January 1994 to August 1998. To identify the risk associated with subdural grid implantation, a retrospective review of all patients' medical records and radiological studies was performed. The major complications of 50 subdural grid electrode implantations were as follows: four cases (7.8%) of delayed subdural hematoma at the site of the subdural grid, requiring emergency operation; two cases (3.9%) of infection; one case (2.0%) of epidural hematoma; and one case (2.0%) of brain swelling. After subdural hematoma removal, the electrodes were left in place. CCTV monitoring and cortical stimulation studies were continued thereafter. No delayed subdural hematoma has occurred since routine placement of subdural drains was begun. In our experience the worst complication of subdural grid implantation has been delayed subdural hematoma. Placement of subdural drains and close observation may be helpful to prevent this serious complication.

  4. A reliable method for intracranial electrode implantation and chronic electrical stimulation in the mouse brain.

    Science.gov (United States)

    Jeffrey, Melanie; Lang, Min; Gane, Jonathan; Wu, Chiping; Burnham, W McIntyre; Zhang, Liang

    2013-08-06

    Electrical stimulation of brain structures has been widely used in rodent models for kindling or modeling deep brain stimulation used clinically. This requires surgical implantation of intracranial electrodes and subsequent chronic stimulation in individual animals for several weeks. Anchoring screws and dental acrylic have long been used to secure implanted intracranial electrodes in rats. However, such an approach is limited when carried out in mouse models as the thin mouse skull may not be strong enough to accommodate the anchoring screws. We describe here a screw-free, glue-based method for implanting bipolar stimulating electrodes in the mouse brain and validate this method in a mouse model of hippocampal electrical kindling. Male C57 black mice (initial ages of 6-8 months) were used in the present experiments. Bipolar electrodes were implanted bilaterally in the hippocampal CA3 area for electrical stimulation and electroencephalographic recordings. The electrodes were secured onto the skull via glue and dental acrylic but without anchoring screws. A daily stimulation protocol was used to induce electrographic discharges and motor seizures. The locations of implanted electrodes were verified by hippocampal electrographic activities and later histological assessments. Using the glue-based implantation method, we implanted bilateral bipolar electrodes in 25 mice. Electrographic discharges and motor seizures were successfully induced via hippocampal electrical kindling. Importantly, no animal encountered infection in the implanted area or a loss of implanted electrodes after 4-6 months of repetitive stimulation/recording. We suggest that the glue-based, screw-free method is reliable for chronic brain stimulation and high-quality electroencephalographic recordings in mice. The technical aspects described this study may help future studies in mouse models.

  5. Long-term biocompatibility of implanted polymer-based intrafascicular electrodes

    DEFF Research Database (Denmark)

    Lawrence, Stephen M; Larsen, Jytte Overgaard; Horch, Kenneth W

    2002-01-01

    Polymer-based longitudinal intrafascicular electrodes (polyLIFEs) were chronically implanted into the sciatic nerve of white New Zealand rabbits (n=8) for a period of 6 months (hereafter referred to as the long-term group). The impact of the implantation procedure, as observed 6 months post surge...

  6. Modifying cochlear implant design: advantages of placing a return electrode in the modiolus.

    Science.gov (United States)

    Ho, Steven Y; Wiet, Richard J; Richter, Claus-Peter

    2004-07-01

    A modiolar return electrode significantly increases the current flow across spiral ganglion cells into the modiolus, and may decrease the cochlear implant's power requirements. Ideal cochlear implants should maximize current flow into the modiolus to stimulate auditory neurons. Previous efforts to facilitate current flow through the modiolus included the fabrication and use of precurved electrodes designed to "hug" the modiolus and silastic positioners designed to place the electrodes closer to the modiolus. In contrast to earlier efforts, this study explores the effects of return electrode placement on current distributions in the modiolus. The effects of return electrode positioning on current flow in the modiolus were studied in a Plexiglas model of the cochlea. Results of model measurements were confirmed by measurements in the modiolus of human temporal bones. The return electrode was placed either within the modiolus, or remotely, outside the temporal bone, simulating contemporary cochlear implant configurations using monopolar stimulation. Cochlear model results clearly show that modiolar current amplitudes can be influenced significantly by the location of the return electrode, being larger when placed into the modiolus. Temporal bone data show similar findings. Voltages recorded in the modiolus are, on average, 2.8 times higher with the return electrode in the modiolus compared with return electrode locations outside the temporal bone. Placing a cochlear implant's return electrode in the modiolus should significantly reduce its power consumption. Reducing power requirements should lead to improved efficiency, safer long-term use, and longer device life.

  7. Selecting electrode configurations for image-guided cochlear implant programming using template matching.

    Science.gov (United States)

    Zhang, Dongqing; Zhao, Yiyuan; Noble, Jack H; Dawant, Benoit M

    2018-04-01

    Cochlear implants (CIs) are neural prostheses that restore hearing using an electrode array implanted in the cochlea. After implantation, the CI processor is programmed by an audiologist. One factor that negatively impacts outcomes and can be addressed by programming is cross-electrode neural stimulation overlap (NSO). We have proposed a system to assist the audiologist in programming the CI that we call image-guided CI programming (IGCIP). IGCIP permits using CT images to detect NSO and recommend deactivation of a subset of electrodes to avoid NSO. We have shown that IGCIP significantly improves hearing outcomes. Most of the IGCIP steps are robustly automated but electrode configuration selection still sometimes requires manual intervention. With expertise, distance-versus-frequency curves, which are a way to visualize the spatial relationship learned from CT between the electrodes and the nerves they stimulate, can be used to select the electrode configuration. We propose an automated technique for electrode configuration selection. A comparison between this approach and one we have previously proposed shows that our method produces results that are as good as those obtained with our previous method while being generic and requiring fewer parameters.

  8. Auditory brainstem activity and development evoked by apical versus basal cochlear implant electrode stimulation in children.

    Science.gov (United States)

    Gordon, K A; Papsin, B C; Harrison, R V

    2007-08-01

    The role of apical versus basal cochlear implant electrode stimulation on central auditory development was examined. We hypothesized that, in children with early onset deafness, auditory development evoked by basal electrode stimulation would differ from that evoked more apically. Responses of the auditory nerve and brainstem, evoked by an apical and a basal implant electrode, were measured over the first year of cochlear implant use in 50 children with early onset severe to profound deafness who used hearing aids prior to implantation. Responses at initial stimulation were of larger amplitude and shorter latency when evoked by the apical electrode. No significant effects of residual hearing or age were found on initial response amplitudes or latencies. With implant use, responses evoked by both electrodes showed decreases in wave and interwave latencies reflecting decreased neural conduction time through the brainstem. Apical versus basal differences persisted with implant experience with one exception; eIII-eV interlatency differences decreased with implant use. Acute stimulation shows prolongation of basally versus apically evoked auditory nerve and brainstem responses in children with severe to profound deafness. Interwave latencies reflecting neural conduction along the caudal and rostral portions of the brainstem decreased over the first year of implant use. Differences in neural conduction times evoked by apical versus basal electrode stimulation persisted in the caudal but not rostral brainstem. Activity-dependent changes of the auditory brainstem occur in response to both apical and basal cochlear implant electrode stimulation.

  9. Design of a new electrode array for cochlear implants

    International Nuclear Information System (INIS)

    Kha, H.; Chen, B.

    2010-01-01

    Full text: This study aims to design a new electrode array which can be precisely located beneath the basilar membrane within the cochlear scala tympani. This placement of the electrode array is beneficial for increasing the effectiveness of the electrical stimulation of the audi tory nerves and maximising the growth factors delivered into the cochlea for regenerating the progressively lost auditory neurons, thereby significantly improving performance of the cochlear implant systems. Methods The design process involved two steps. First, the biocom patible nitinol-based shape memory alloy, of which mechanical deformation can be controlled using electrical cUTents/fields act vated by body temperature, was selected. Second, five different designs of the electrode array with embedded nitinol actuators were studied (Table I). The finite element method was employed to predict final positions of these electrode arrays. Results The electrode array with three 6 mm actuators at 2-8, 8-J4 and 14-20 mm from the tip (Fig. I) was found to be located most closely to the basilar membrane, compared with those in the other four cases. Conclusions A new nitinol cochlear implant electrode array with three embedded nitinol actuators has been designed. This electrode array is expected to be located beneath the basilar membrane for maximising the delivery of growth factors. Future research will involve the manufacturing of a prototype of this electrode array for use in insertion experiments and neurotrophin release tests.

  10. Improving neuromodulation technique for refractory voiding dysfunctions: two-stage implant.

    Science.gov (United States)

    Janknegt, R A; Weil, E H; Eerdmans, P H

    1997-03-01

    Neuromodulation is a new technique that uses electrical stimulation of the sacral nerves for patients with refractory urinary urge/frequency or urge-incontinence, and some forms of urinary retention. The limiting factor for receiving an implant is often a failure of the percutaneous nerve evaluation (PNE) test. Present publications mention only about a 50% success score for PNE of all patients, although the micturition diaries and urodynamic parameters are similar. We wanted to investigate whether PNE results improved by using a permanent electrode as a PNE test. This would show that improvement of the PNE technique is feasible. In 10 patients where the original PNE had failed to improve the micturition diary parameters more than 50%, a permanent electrode was implanted by operation. It was connected to an external stimulator. In those cases where the patients improved according to their micturition diary by more than 50% during a period of 4 days, the external stimulator was replaced by a permanent subcutaneous neurostimulator. Eight of the 10 patients had a good to very good result (60% to 90% improvement) during the testing period and received their implant 5 to 14 days after the first stage. The good results of the two-stage implant technique we used indicate that the development of better PNE electrodes may lead to an improvement of the testing technique and better selection between nonresponders and technical failures.

  11. Permanent I-125 interstitial implant in the management of high grade CNS malignancies in children

    International Nuclear Information System (INIS)

    Vaishampayan, N.; Zamorano, L.; Aronin, P.; Gaspar, L.; Canady, A.; Lattin, P.; Ezzell, G.; Yakar, D.; Chungbin, S.; Fontanesi, J.

    1996-01-01

    Purpose/Objective: To evaluate the efficacy and complications associated with the use of permanent I-125 interstitial implants in children with high grade CNS malignancies. Materials and Methods: Between May of 1990 and September of 1994, fourteen children received permanent I-125 interstitial implant brachytherapy as initial therapy (n=8) or at time of recurrence (n=6). Histologies included Glioblastoma Multiforme (n=2), Anaplastic Astrocytoma (n=9) and others (n=3). Pre-implant surgical procedures included: Gross Total Resection (n=2), Subtotal Resection (n=8) or Biopsy alone (n=4). Six patients received pre-implant external beam irradiation (dose range 3,500-6500 cGy) and three patients received post-implant external beam irradiation (dose range 5,040-5,060 cGy). Implant dose range was 8,294-10,368 cGy over the lifetime of the implant (median 10,368 cGy). Results: At last follow-up (median 17.5 months; range 4-56 months), eight children were alive. Six out of the eight had no evidence of disease progression while the remaining had radiologic evidence of progression. Implant complications (n=2) included skin necrosis and bone flap infection. Conclusions: Based on this initial review, we continue to investigate the use of permanent I-125 interstitial brachytherapy in the treatment of high grade CNS malignancies in children and will discuss and compare these results with those of other 'Boost' series

  12. SU-F-J-167: Use of MR for Permanent Prostate Implant Preplanning

    Energy Technology Data Exchange (ETDEWEB)

    Narayana, V; McLaughlin, P [Assarian Cancer Center, Novi, MI (United States); University of Michigan, Ann Arbor, MI (United States); Yao, B [Assarian Cancer Center, Novi, MI (United States)

    2016-06-15

    Purpose: To study the feasibility using MR imaging to improve target definition on ultrasound during permanent prostate implants and aid in source strength determination for treatment planning in the OR. Methods: Patients who receive permanent prostate implants undergo MR and CT imaging prior to the implant procedure to determine the volume of the prostate, bony restriction to the procedure, bladder extension, external sphincter length and neurovascular bundle. The volume of the prostate is generally used to order seeds for the procedure. In 10 patients, the MR was used as the preplanning study with the PTV defined as a 2 mm expansion of the MR prostate in all directions except the posterior. Various dose volume parameters for the MR prostate and the PTV were compared to the actual preplan developed and executed in the OR. In addition, there parameters were compared to the post implant dosimetry performed 3 weeks after the implant procedure. Results: The results show that the number of seeds used using MR and US (ultrasound) planning was generally with 2 seeds and the maximum difference was 7 seeds. There is no significant difference between any of the dose index parameters of V100, V150, V200, D99 and D90 parameters between MR planning, US planning and postimplant evaluation There was a significant difference between planned D99 (avg of 105%) and achieved D99 (avg 91%). Conclusion: MR imaging is an invaluable tool to improve target definition for permanent prostate implants. Use of MR images for preplanning improves the confidence with which source can be ordered for the procedure that is OR planned. Ordering a maximum of 10 seeds more than planned would be sufficient to deliver a plan in the OR using US. Moving ahead to non-rigid registration between MR ad US images could further increase the confidence level of MR planning.

  13. Urethral alarm probe for permanent prostate implants

    International Nuclear Information System (INIS)

    Cutajar, D.; Lerch, M.; Takacs, G.

    2008-01-01

    We have developed a urethral dosimetry system for real time dose verification along the urethra during permanent implant prostate brachytherapy. The urethral alarm uses 'spectroscopic dosimetry' to calculate the dose rate along the urethra in real time. The application of spectroscopic dosimetry for the urethral alarm probe was verified using Monte Carlo calculations. In phantom depth dose measurements as well as isotropy measurements were performed to verify the usefulness of the urethra alarm probe as an in vivo real time dosimeter. (author)

  14. Fabrication of Pillar Shaped Electrode Arrays for Artificial Retinal Implants

    Directory of Open Access Journals (Sweden)

    Sung June Kim

    2008-09-01

    Full Text Available Polyimide has been widely applied to neural prosthetic devices, such as the retinal implants, due to its well-known biocompatibility and ability to be micropatterned. However, planar films of polyimide that are typically employed show a limited ability in reducing the distance between electrodes and targeting cell layers, which limits site resolution for effective multi-channel stimulation. In this paper, we report a newly designed device with a pillar structure that more effectively interfaces with the target. Electrode arrays were successfully fabricated and safely implanted inside the rabbit eye in suprachoroidal space. Optical Coherence Tomography (OCT showed well-preserved pillar structures of the electrode without damage. Bipolar stimulation was applied through paired sites (6:1 and the neural responses were successfully recorded from several regions in the visual cortex. Electrically evoked cortical potential by the pillar electrode array stimulation were compared to visual evoked potential under full-field light stimulation.

  15. Intracranial EEG fluctuates over months after implanting electrodes in human brain

    Science.gov (United States)

    Ung, Hoameng; Baldassano, Steven N.; Bink, Hank; Krieger, Abba M.; Williams, Shawniqua; Vitale, Flavia; Wu, Chengyuan; Freestone, Dean; Nurse, Ewan; Leyde, Kent; Davis, Kathryn A.; Cook, Mark; Litt, Brian

    2017-10-01

    Objective. Implanting subdural and penetrating electrodes in the brain causes acute trauma and inflammation that affect intracranial electroencephalographic (iEEG) recordings. This behavior and its potential impact on clinical decision-making and algorithms for implanted devices have not been assessed in detail. In this study we aim to characterize the temporal and spatial variability of continuous, prolonged human iEEG recordings. Approach. Intracranial electroencephalography from 15 patients with drug-refractory epilepsy, each implanted with 16 subdural electrodes and continuously monitored for an average of 18 months, was included in this study. Time and spectral domain features were computed each day for each channel for the duration of each patient’s recording. Metrics to capture post-implantation feature changes and inflexion points were computed on group and individual levels. A linear mixed model was used to characterize transient group-level changes in feature values post-implantation and independent linear models were used to describe individual variability. Main results. A significant decline in features important to seizure detection and prediction algorithms (mean line length, energy, and half-wave), as well as mean power in the Berger and high gamma bands, was observed in many patients over 100 d following implantation. In addition, spatial variability across electrodes declines post-implantation following a similar timeframe. All selected features decreased by 14-50% in the initial 75 d of recording on the group level, and at least one feature demonstrated this pattern in 13 of the 15 patients. Our findings indicate that iEEG signal features demonstrate increased variability following implantation, most notably in the weeks immediately post-implant. Significance. These findings suggest that conclusions drawn from iEEG, both clinically and for research, should account for spatiotemporal signal variability and that properly assessing the iEEG in

  16. Modeling of electrodes and implantable pulse generator cases for the analysis of implant tip heating under MR imaging

    International Nuclear Information System (INIS)

    Acikel, Volkan; Atalar, Ergin; Uslubas, Ali

    2015-01-01

    Purpose: The authors’ purpose is to model the case of an implantable pulse generator (IPG) and the electrode of an active implantable medical device using lumped circuit elements in order to analyze their effect on radio frequency induced tissue heating problem during a magnetic resonance imaging (MRI) examination. Methods: In this study, IPG case and electrode are modeled with a voltage source and impedance. Values of these parameters are found using the modified transmission line method (MoTLiM) and the method of moments (MoM) simulations. Once the parameter values of an electrode/IPG case model are determined, they can be connected to any lead, and tip heating can be analyzed. To validate these models, both MoM simulations and MR experiments were used. The induced currents on the leads with the IPG case or electrode connections were solved using the proposed models and the MoTLiM. These results were compared with the MoM simulations. In addition, an electrode was connected to a lead via an inductor. The dissipated power on the electrode was calculated using the MoTLiM by changing the inductance and the results were compared with the specific absorption rate results that were obtained using MoM. Then, MRI experiments were conducted to test the IPG case and the electrode models. To test the IPG case, a bare lead was connected to the case and placed inside a uniform phantom. During a MRI scan, the temperature rise at the lead was measured by changing the lead length. The power at the lead tip for the same scenario was also calculated using the IPG case model and MoTLiM. Then, an electrode was connected to a lead via an inductor and placed inside a uniform phantom. During a MRI scan, the temperature rise at the electrode was measured by changing the inductance and compared with the dissipated power on the electrode resistance. Results: The induced currents on leads with the IPG case or electrode connection were solved for using the combination of the MoTLiM and

  17. Electrode impedance analysis of chronic tungsten microwire neural implants: understanding abiotic vs. biotic contributions

    Directory of Open Access Journals (Sweden)

    Viswanath eSankar

    2014-05-01

    Full Text Available Changes in biotic and abiotic factors can be reflected in the complex impedance spectrum of the microelectrodes chronically implanted into the neural tissue. The recording surface of the tungsten electrode in vivo undergoes abiotic changes due to recording site corrosion and insulation delamination as well as biotic changes due to tissue encapsulation as a result of the foreign body immune response. We reported earlier that large changes in electrode impedance measured at 1 kHz were correlated with poor electrode functional performance, quantified through electrophysiological recordings during the chronic lifetime of the electrode. There is a need to identity the factors that contribute to the chronic impedance variation. In this work, we use numerical simulation and regression to equivalent circuit models to evaluate both the abiotic and biotic contributions to the impedance response over chronic implant duration. COMSOL® simulation of abiotic electrode morphology changes provide a possible explanation for the decrease in the electrode impedance at long implant duration while biotic changes play an important role in the large increase in impedance observed initially.

  18. Evaluation of permanent I-125 prostate implants using radiographs and MRI

    International Nuclear Information System (INIS)

    Moerland, M.A.; Beersma, R.; Bhagwandien, R.; Wijrdeman, H.K.; Battermann, J.J.

    1995-01-01

    Introduction: Localized prostatic cancer is managed by radical prostatectomy, external beam irradiation or a permanent implant with I-125 seeds. Permanent implants are indicated for small tumours (T1-T2) with a well to moderate histological differentiation. The technique used is a transrectal ultrasound guided transperineal implantation technique, which aims for a seed and dose distribution such that the initial doserate line of 7.8 cGy/h encompasses the prostate resulting in an accumulated dose of 160 Gy. Up till now the seed and dose distribution is evaluated from isocentric radiographs, which do not show the relation with the prostate. Objectives: The aim of this study is the development of a technique to reconstruct and evaluate the seed and dose distribution within the prostate. Methods: Twenty patients underwent radiography on the simulator and scanning on a whole body NMR system within 3 days after implantation of the I-125 seeds. Isocentric radiographs were used for reconstruction of the seed distribution, after which registration with the MR images provided the seed positions in relation to the prostate. Volume dose histograms were used to evaluate the implants. Results: The I-125 seeds and the prostate anatomy were well depicted on T1-weighted spin echo images with minimal read out gradient strength. To date, ten implants were evaluated. According to our method, the prostate volumes receiving the prescribed dose of 160 Gy ranged from 30 to 70% of the total prostate volumes. Conclusion: The combination of isocentric radiographs and MRI enables reconstruction of the seed and dose distribution in relation to the prostate and the computation of dose volume histograms, which may be of value in the evaluation of implant quality

  19. A second defibrillator chest patch electrode will increase implantation rates for nonthoracotomy defibrillators.

    Science.gov (United States)

    Solomon, A J; Swartz, J F; Rodak, D J; Moore, H J; Hannan, R L; Tracy, C M; Fletcher, R D

    1996-09-01

    Nonthoracotomy defibrillator systems can be implanted with a lower morbidity and mortality, compared to epicardial systems. However, implantation may be unsuccessful in up to 15% of patients, using a monophasic waveform. It was the purpose of this study to prospectively examine the efficacy of a second chest patch electrode in a nonthoracotomy defibrillator system. Fourteen patients (mean age 62 +/- 11 years, ejection fraction = 0.29 +/- 0.12) with elevated defibrillation thresholds, defined as > or = 24 J, were studied. The initial lead system consisted of a right ventricular electrode (cathode), a left innominate vein, and subscapular chest patch electrode (anodes). If the initial defibrillation threshold was > or = 24 J, a second chest patch electrode was added. This was placed subcutaneously in the anterior chest (8 cases), or submuscularly in the subscapular space (6 cases). This resulted in a decrease in the system impedance at the defibrillation threshold, from 72.3 +/- 13.3 omega to 52.2 +/- 8.6 omega. Additionally, the defibrillation threshold decreased from > or = 24 J, with a single patch, to 16.6 +/- 2.8 J with two patches. These changes were associated with successful implantation of a nonthoracotomy defibrillator system in all cases. In conclusion, the addition of a second chest patch electrode (using a subscapular approach) will result in lower defibrillation thresholds in patients with high defibrillation thresholds, and will subsequently increase implantation rates for nonthoracotomy defibrillators.

  20. Treatment planning for permanent and temporary percutaneous implants with custom made templates

    International Nuclear Information System (INIS)

    Osian, A.D.; Anderson, L.L.; Linares, L.A.; Nori, D.; Hilaris, B.S.

    1989-01-01

    Nine patients who were presented at MSKCC with primary or recurrent pelvic or head and neck tumors and for whom surgery or further external radiation were excluded, were treated with percutaneous permanent or temporary implants, with individual pre-treatment planning and custom made templates. The tumor dose distributions achieved were as good as for implants performed at the time of surgical exploration. No serious complications have been encountered

  1. Behavioral and cellular consequences of high-electrode count Utah Arrays chronically implanted in rat sciatic nerve

    Science.gov (United States)

    Wark, H. A. C.; Mathews, K. S.; Normann, R. A.; Fernandez, E.

    2014-08-01

    Objective. Before peripheral nerve electrodes can be used for the restoration of sensory and motor functions in patients with neurological disorders, the behavioral and histological consequences of these devices must be investigated. These indices of biocompatibility can be defined in terms of desired functional outcomes; for example, a device may be considered for use as a therapeutic intervention if the implanted subject retains functional neurons post-implantation even in the presence of a foreign body response. The consequences of an indwelling device may remain localized to cellular responses at the device-tissue interface, such as fibrotic encapsulation of the device, or they may affect the animal more globally, such as impacting behavioral or sensorimotor functions. The objective of this study was to investigate the overall consequences of implantation of high-electrode count intrafascicular peripheral nerve arrays, High Density Utah Slanted Electrode Arrays (HD-USEAs; 25 electrodes mm-2). Approach. HD-USEAs were implanted in rat sciatic nerves for one and two month periods. We monitored wheel running, noxious sensory paw withdrawal reflexes, footprints, nerve morphology and macrophage presence at the tissue-device interface. In addition, we used a novel approach to contain the arrays in actively behaving animals that consisted of an organic nerve wrap. A total of 500 electrodes were implanted across all ten animals. Main results. The results demonstrated that chronic implantation (⩽8 weeks) of HD-USEAs into peripheral nerves can evoke behavioral deficits that recover over time. Morphology of the nerve distal to the implantation site showed variable signs of nerve fiber degeneration and regeneration. Cytology adjacent to the device-tissue interface also showed a variable response, with some electrodes having many macrophages surrounding the electrodes, while other electrodes had few or no macrophages present. This variability was also seen along the length

  2. Diversity in cochlear morphology and its influence on cochlear implant electrode position

    NARCIS (Netherlands)

    Marel, K.S. van der; Briaire, J.J.; Wolterbeek, R..; Snel-Bongers, J.; Verbist, B.M.; Frijns, J.H.

    2014-01-01

    To define a minimal set of descriptive parameters for cochlear morphology and study its influence on the cochlear implant electrode position in relation to surgical insertion distance.Cochlear morphology and electrode position were analyzed using multiplanar reconstructions of the pre- and

  3. Zero-fluoroscopy permanent pacemaker implantation using Ensite NavX system: Clinical viability or fanciful technique?

    Science.gov (United States)

    Guo, Ping; Qiu, Jie; Wang, Yan; Chen, Guangzhi; Proietti, Riccardo; Fadhle, Al-Selmi; Zhao, Chunxia; Wen Wang, Dao

    2018-02-01

    Fluoroscopy is the imaging modality routinely used for cardiac device implantation and electrophysiological procedures. Due to the rising concern regarding the harmful effects of radiation exposure to both the patients and operation staffs, novel 3D mapping systems have been developed and implemented in electrophysiological procedure for the navigation of catheters inside the heart chambers. Their applicability in cardiac device implantation has been rarely reported. Our aim is to evaluate the feasibility and safety of permanent pacemaker implantation without fluoroscopy. From January 2012 to June 2016, six patients (50 ± 15 years, four of six were female, one of who was at the 25th week of gestation) who underwent permanent pacemaker implantation were included (zero-fluoroscopy group). Data from 20 consecutive cases of implantation performed under fluoroscopy guidance were chosen as a control group (fluoroscopy group). Total implantation procedure time for single-chamber pacemaker was 51.3 ± 13.1 minutes in the zero-fluoroscopy group and 42.6 ± 7.4 minutes in the fluoroscopy group (P  =  0.155). The implantation procedural time for a dual-chamber pacemaker was 88.3 ± 19.6 minutes and 67.3 ± 7.6 minutes in the zero-fluoroscopy and fluoroscopy groups (P  =  0.013), respectively. No complications were observed during the procedure and the follow-up in the two groups, and all pacemakers worked with satisfactory parameters. Ensite NavX system can be used as a reliable and safe zero-fluoroscopy approach for the implantation of single- or dual-chamber permanent pacemakers in specific patients, such as pregnant women or in extreme situations when the x-ray machine is not available. © 2017 The Authors. Pacing and Clinical Electrophysiology published by Wiley Periodicals, Inc.

  4. Influence of source batch Sk dispersion on dosimetry for prostate cancer treatment with permanent implants

    DEFF Research Database (Denmark)

    Nunez-Cumplido, Eduardo; Perez-Calatayud, J; Casares-Magaz, O

    2015-01-01

    PURPOSE: In clinical practice, specific air kerma strength (SK) value is used in treatment planning system (TPS) permanent brachytherapy implant calculations with (125)I and (103)Pd sources; in fact, commercial TPS provide only one SK input value for all implanted sources and the certified shipment...

  5. Permanent LDR implants in treatment of prostate cancer

    International Nuclear Information System (INIS)

    Skowronek, J.; Kanikowski, M.; Chichel, A.; Zwierzchowski, G.

    2009-01-01

    Low-dose rate brachytherapy (LDR-BT) is a radiation method known for several years in the treatment of localized prostate cancer. The main idea of this method is to implant small radioactive seeds directly into the prostate gland. LDR brachytherapy is applied as a monotherapy and also used along with external beam radiation therapy (EBRT) as a boost. In most cases it is used as a sole radical treatment modality, but not as a palliative treatment. The application of permanent seed implants is a curative treatment alternative in patients with organ- confined cancer, without extracapsular extension of the tumour. This technique is particularly popular in the United States. In Europe, however, high-dose rate brachytherapy (HDR-BT) is more popular in early-stage prostate cancer treatment (as a boost). The aim of this publication is to describe methods, indications, complications and selected results of prostate cancer LDR brachytherapy. (authors)

  6. Ten cases of metastatic cervical cancer with the treatment of permanent 125I seeds interstitial implants

    International Nuclear Information System (INIS)

    Zhang Hongwei; Li Naibin; Li Qingxin; Liu Huiping; Meng Hui; Chao Dong

    2011-01-01

    Objective: To investigate the clinical effect of permanent 125 I seeds interstitial implants for metastatic cervical cancer. Methods: Under the guidance of the B-sonography, 125 I seeds were implanted into the eleven cervical lymph nodes of ten patients who had been given tumor resection. The pain relief and tumor size were observed in regular follow-up after one-month treatment. Results: All the patients were followed up for 6-14 months,and the postoperative recovery was good with no complication. One month after the implantation, the pain symptom was alleviated entirely in two nodes and partly in nine nodes. The tumor size shrank in ten nodes while there was no change in one node after one month. Conclusion: Permanent 125 I seeds interstitial implants for metastatic cervical cancer is a safe, minimally invasive and effective treatment. (authors)

  7. Dosimetric intercomparison of permanent Ho-166 seed's implants and HDR Ir-192 brachytherapy in breast cancer.

    Science.gov (United States)

    de Campos, Tarcisio Passos Ribeiro; Nogueira, Luciana Batista; Trindade, Bruno; Cuperschmid, Ethel Mizrahy

    2016-01-01

    To provide a comparative dosimetric analysis of permanent implants of Ho(166)-seeds and temporary HDR Ir(192)-brachytherapy through computational simulation. Brachytherapy with Ir(192)-HDR or LDR based on temporary wires or permanent radioactive seed implants can be used as dose reinforcement for breast radiation therapy. Permanent breast implants have not been a practical clinical routine; although, I(125) and Pd(103)-seeds have already been reported. Biodegradable Ho(166)-ceramic-seeds have been addressed recently. Simulations of implants of nine Ho(166)-seeds and equivalent with HDR Ir(192)-brachytherapy were elaborated in MCNP5, shaped in a computational multivoxel simulator which reproduced a female thorax phantom. Spatial dose rate distributions and dose-volume histograms were generated. Protocol's analysis involving exposure time, seed's activities and dose were performed. Permanent Ho(166)-seed implants presented a maximum dose rate per unit of contained activity (MDR) of 1.1601 μGy h(-1) Bq(-1); and, a normalized MDR in standard points (8 mm, equidistant to 03-seeds - SP1, 10 mm - SP2) of 1.0% (SP1) and 0.5% (SP2), respectively. Ir(192)-brachytherapy presented MDR of 4.3945 × 10(-3) μGy h(-1) Bq(-1); and, 30% (SP1), and 20% (SP2). Therefore, seed's implant activities of 333 MBq (Ho(166)) and 259 GBq (Ir(192)) produced prescribed doses of 58 Gy (SP1; 5d) and 56 Gy (SP1, 5 fractions, 6 min), respectively. Breast Ho(166)-implants of 37-111 MBq are attractive due to the high dose rate near 6-10 mm from seeds, equivalent to Ir(192)-brachytherapy of 259 GBq (3 fractions, 6 min) providing similar dose in standard points at a week; however, with spatial dose distribution better confined. The seed positioning can be adjusted for controlling the breast tumor, in stages I and II, in flat and deep tumors, without any breast volumetric limitation.

  8. Occupational exposure of professionals during interstitial permanent prostate brachytherapy implants

    International Nuclear Information System (INIS)

    Pirraco, R.; Pereira, A.; Viterbo, T.; Cavaco, A.

    2006-01-01

    Full text of publication follows: Introduction: In this study we present dose measurements for professionals exposed during interstitial 125 I permanent prostate brachytherapy implants. Methods and Materials: The implant technique used was intra operative real time using strand and loose seeds. The professionals inside the operating room are an oncologist, a radiologist, a physicist, a nurse and an anesthesiologist. The oncologist and the physicist contact directly the loaded needle with radioactive seeds and two types of measurements were taken: total body and extremities (finger) dose. The rest of the team operates at long distances, but measurements were made. To measure total body equivalent dose we use a Berthold Umo LB 123 coupled with a LB 1236-H10 detector, and we recorded dose, time and distance from implant location. Finger dosemeters are thermo -luminescent dosimeter (TLD) rings that were controlled over one month. Results: 50 cases (average number of applications per year) were analysed for extremities measurements and 9 cases for total body measurements (in this case, the results were extrapolated for 50 cases), with an average of 26.1 mCi total activity per implant (in a range of 17.4 - 40.3 mCi). The finger dose was 1.8 mSv for the oncologist and 1.9 mSv for the physicist. The interpolation of total body equivalent dose for the oncologist was 24 mSv, for the radiologist 6 mSv and 9 mSv for the physicist. The rest of the team did not receive anything but background radiation. The annual national limit dose for workers is 20 mSv for total body irradiation, and 500 mSv for extremities. Conclusion: In conclusion we may say that during interstitial permanent prostate brachytherapy implants, total doses received for all groups are not significant when compared to annual limits for Portuguese laws 1. Even so, our main goal is always to get the less possible dose (ALARA principle). References: 1. Decreto Lei n. 180/2002 de 8 de Agosto. (authors)

  9. Occupational exposure of professionals during interstitial permanent prostate brachytherapy implants

    Energy Technology Data Exchange (ETDEWEB)

    Pirraco, R.; Pereira, A.; Viterbo, T.; Cavaco, A. [Instituto Portugues de Oncologia Francisco Gentil, Centro R egional de Oncologia do Porto, SA, Porto (Portugal)

    2006-07-01

    Full text of publication follows: Introduction: In this study we present dose measurements for professionals exposed during interstitial 125 I permanent prostate brachytherapy implants. Methods and Materials: The implant technique used was intra operative real time using strand and loose seeds. The professionals inside the operating room are an oncologist, a radiologist, a physicist, a nurse and an anesthesiologist. The oncologist and the physicist contact directly the loaded needle with radioactive seeds and two types of measurements were taken: total body and extremities (finger) dose. The rest of the team operates at long distances, but measurements were made. To measure total body equivalent dose we use a Berthold Umo LB 123 coupled with a LB 1236-H10 detector, and we recorded dose, time and distance from implant location. Finger dosemeters are thermo -luminescent dosimeter (TLD) rings that were controlled over one month. Results: 50 cases (average number of applications per year) were analysed for extremities measurements and 9 cases for total body measurements (in this case, the results were extrapolated for 50 cases), with an average of 26.1 mCi total activity per implant (in a range of 17.4 - 40.3 mCi). The finger dose was 1.8 mSv for the oncologist and 1.9 mSv for the physicist. The interpolation of total body equivalent dose for the oncologist was 24 mSv, for the radiologist 6 mSv and 9 mSv for the physicist. The rest of the team did not receive anything but background radiation. The annual national limit dose for workers is 20 mSv for total body irradiation, and 500 mSv for extremities. Conclusion: In conclusion we may say that during interstitial permanent prostate brachytherapy implants, total doses received for all groups are not significant when compared to annual limits for Portuguese laws 1. Even so, our main goal is always to get the less possible dose (ALARA principle). References: 1. Decreto Lei n. 180/2002 de 8 de Agosto. (authors)

  10. Cochlear implant electrode localization in post-operative CT using a spherical measure

    DEFF Research Database (Denmark)

    Braithwaite, Benjamin Michael; Kjer, Hans Martin; Fagertun, Jens

    2016-01-01

    the ordering of electrode contacts on implanted electrode arrays from post-operative CT images. Our method applies a specialized filter chain to the images based on a threshold and spherical measure, and selects contact positions at local maxima in the filtered image. Two datasets of 13 temporal bone specimens...

  11. Essure Permanent Birth Control

    Science.gov (United States)

    ... Prosthetics Essure Permanent Birth Control Essure Permanent Birth Control Share Tweet Linkedin Pin it More sharing options ... Print Essure is a a permanently implanted birth control device for women (female sterilization). Implantation of Essure ...

  12. Radiation protection after interstitial permanent prostate brachytherapy implants

    Energy Technology Data Exchange (ETDEWEB)

    Pirraco, R.; Pereira, A.; Cavaco, A. [Instituto Portugues de Oncologia Francisco Gentil - Centro R egional de Oncologia do Porto, SA, Porto (Portugal)

    2006-07-01

    Full text of publication follows: In this study we measure patients radiation exposure dose after interstitial {sup 125}I permanent prostate Brachytherapy implants, and correlate it with dose limits for public, total activity implanted, patient preoperative weight(1), distance between prostate walls and anterior skin surface. Methods and Material: We analyse 20 patients who were implanted with {sup 125}I seeds. The instrument used to measure radiation is a calibrated Berthold Umo LB 123 aco-plated to a LB 1236-H10 detector. Three measurements were taken: at the perineal and anterior pelvic zones on contact with the skin and at 1 m from the patient. The maximum value was taken for all measurements. The dose at a distance of one meter is obtained at anterior pelvic zone, perpendicular to the skin, according to the recommendations of A.A.P.M.(1). The distance between prostate walls was determined using post -operative CT images. Results: The doses at the perineal zone have determined an average of 186 {mu}Sv/h (range: 110 340 {mu}Sv/h) and at surface pelvic zone of 41 {mu}Sv/h (range: 15 103 {mu}Sv/h). The dose at a distance of 1 meter has an average value of 0.4 {mu}Sv/h (range: 0.2 1.0 {mu}Sv/h). The average total activity implanted was 25 mCi (range: 17 38 mCi). The distance between prostate walls and skin pelvic surface of the patients has an average value of 8.9 cm (range: 6.6 -11.5 cm). At a distance of 1 meter from the pelvic zone the dose measured is very low and below dose limits imposed by the European Directive EURATOM 2 and the Portuguese law. For general public to reach annual dose limit (EURATOM - 1 mSv/year) when contacting the pelvic zone, we extrapolate that 4 days (range: 1.6 11.1 days) would be needed, assuming a daily contact period of 6 hours. Conclusion: We established a correlation between the distance of prostate walls to the skin perineal surface and the total dose, but we find no correlation between measured doses, total activity implanted

  13. Determination of prescription dose for Cs-131 permanent implants using the BED formalism including resensitization correction

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Wei, E-mail: wei.luo@uky.edu; Molloy, Janelle; Aryal, Prakash; Feddock, Jonathan; Randall, Marcus [Department of Radiation Medicine, University of Kentucky, Lexington, Kentucky 40536 (United States)

    2014-02-15

    Purpose: The current widely used biological equivalent dose (BED) formalism for permanent implants is based on the linear-quadratic model that includes cell repair and repopulation but not resensitization (redistribution and reoxygenation). The authors propose a BED formalism that includes all the four biological effects (4Rs), and the authors propose how it can be used to calculate appropriate prescription doses for permanent implants with Cs-131. Methods: A resensitization correction was added to the BED calculation for permanent implants to account for 4Rs. Using the same BED, the prescription doses with Au-198, I-125, and Pd-103 were converted to the isoeffective Cs-131 prescription doses. The conversion factor F, ratio of the Cs-131 dose to the equivalent dose with the other reference isotope (F{sub r}: with resensitization, F{sub n}: without resensitization), was thus derived and used for actual prescription. Different values of biological parameters such as α, β, and relative biological effectiveness for different types of tumors were used for the calculation. Results: Prescription doses with I-125, Pd-103, and Au-198 ranging from 10 to 160 Gy were converted into prescription doses with Cs-131. The difference in dose conversion factors with (F{sub r}) and without (F{sub n}) resensitization was significant but varied with different isotopes and different types of tumors. The conversion factors also varied with different doses. For I-125, the average values of F{sub r}/F{sub n} were 0.51/0.46, for fast growing tumors, and 0.88/0.77 for slow growing tumors. For Pd-103, the average values of F{sub r}/F{sub n} were 1.25/1.15 for fast growing tumors, and 1.28/1.22 for slow growing tumors. For Au-198, the average values of F{sub r}/F{sub n} were 1.08/1.25 for fast growing tumors, and 1.00/1.06 for slow growing tumors. Using the biological parameters for the HeLa/C4-I cells, the averaged value of F{sub r} was 1.07/1.11 (rounded to 1.1), and the averaged value of F

  14. Determination of prescription dose for Cs-131 permanent implants using the BED formalism including resensitization correction

    International Nuclear Information System (INIS)

    Luo, Wei; Molloy, Janelle; Aryal, Prakash; Feddock, Jonathan; Randall, Marcus

    2014-01-01

    Purpose: The current widely used biological equivalent dose (BED) formalism for permanent implants is based on the linear-quadratic model that includes cell repair and repopulation but not resensitization (redistribution and reoxygenation). The authors propose a BED formalism that includes all the four biological effects (4Rs), and the authors propose how it can be used to calculate appropriate prescription doses for permanent implants with Cs-131. Methods: A resensitization correction was added to the BED calculation for permanent implants to account for 4Rs. Using the same BED, the prescription doses with Au-198, I-125, and Pd-103 were converted to the isoeffective Cs-131 prescription doses. The conversion factor F, ratio of the Cs-131 dose to the equivalent dose with the other reference isotope (F r : with resensitization, F n : without resensitization), was thus derived and used for actual prescription. Different values of biological parameters such as α, β, and relative biological effectiveness for different types of tumors were used for the calculation. Results: Prescription doses with I-125, Pd-103, and Au-198 ranging from 10 to 160 Gy were converted into prescription doses with Cs-131. The difference in dose conversion factors with (F r ) and without (F n ) resensitization was significant but varied with different isotopes and different types of tumors. The conversion factors also varied with different doses. For I-125, the average values of F r /F n were 0.51/0.46, for fast growing tumors, and 0.88/0.77 for slow growing tumors. For Pd-103, the average values of F r /F n were 1.25/1.15 for fast growing tumors, and 1.28/1.22 for slow growing tumors. For Au-198, the average values of F r /F n were 1.08/1.25 for fast growing tumors, and 1.00/1.06 for slow growing tumors. Using the biological parameters for the HeLa/C4-I cells, the averaged value of F r was 1.07/1.11 (rounded to 1.1), and the averaged value of F n was 1.75/1.18. F r of 1.1 has been applied to

  15. Modeling the electrode-neuron interface of cochlear implants: effects of neural survival, electrode placement, and the partial tripolar configuration.

    Science.gov (United States)

    Goldwyn, Joshua H; Bierer, Steven M; Bierer, Julie Arenberg

    2010-09-01

    The partial tripolar electrode configuration is a relatively novel stimulation strategy that can generate more spatially focused electric fields than the commonly used monopolar configuration. Focused stimulation strategies should improve spectral resolution in cochlear implant users, but may also be more sensitive to local irregularities in the electrode-neuron interface. In this study, we develop a practical computer model of cochlear implant stimulation that can simulate neural activation in a simplified cochlear geometry and we relate the resulting patterns of neural activity to basic psychophysical measures. We examine how two types of local irregularities in the electrode-neuron interface, variations in spiral ganglion nerve density and electrode position within the scala tympani, affect the simulated neural activation patterns and how these patterns change with electrode configuration. The model shows that higher partial tripolar fractions activate more spatially restricted populations of neurons at all current levels and require higher current levels to excite a given number of neurons. We find that threshold levels are more sensitive at high partial tripolar fractions to both types of irregularities, but these effects are not independent. In particular, at close electrode-neuron distances, activation is typically more spatially localized which leads to a greater influence of neural dead regions. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  16. Electro active polymers : novel bio-electrodes and implants for urinary continence

    Energy Technology Data Exchange (ETDEWEB)

    Rajagopalan, S.; Sawan, M.; Savadogo, O. [Ecole Polytechnique, Montreal, PQ (Canada). Laboratoire de nouveaux materiaux pour les systemes electrochimiques et energetiques

    2006-07-01

    This paper presented a technical solution to spinal cord injuries that result in urinary bladder dysfunction. It involves miniaturized implants based on polypyrrole, an electroactive polymer, as smart drug-eluting electrodes for neural stimulation to restore bladder function. The nerve-electrode interface is the most vulnerable point in the design and operation of neuro-electronic implants. The main disadvantages are decreased impedance and protein build-up at the stimulation site due to an inflammatory reaction. Polypyrrole is a naturally conducting polymer having both electron-conducting properties as well as actuating properties, rendering it suitable as a drug-eluting electrode for a neurostimulator. Polypyrrole electrochemically coated on platinum increases biocompatibility and reduces electric impedance by increasing the surface area of the electrode. When electrically stimulated, polypyrrole also serves as a matrix to release a negatively-charged anti-inflammatory drug fosfosal. This technology may prove useful in reconstructing a severely damaged bladder through electroactive biomaterials. Polyelectrolyte gels, such as poly(sodium) acrylate, reversibly contract and relax when activated electrically or under the influx of divalent ions. These artificial muscles can be connected to a polypyrrole strain sensor to alert the microcontroller to activate the sphincter muscle, thereby creating an artificial bladder.

  17. Transvenous permanent pacemaker implantation in dextrocardia: technique, challenges, outcome, and a brief review of literature.

    Science.gov (United States)

    Shenthar, Jayaprakash; Rai, Maneesh K; Walia, Rohit; Ghanta, Somasekhar; Sreekumar, Praveen; Reddy, Satish S

    2014-09-01

    Dextrocardia is a rare congenital anomaly. Pacemaker implantation in dextrocardia can be challenging because of the distorted anatomy and associated anomalies. The literature regarding implantation of pacemaker in dextrocardia is scarce. The study involved retrospective analysis of records of patients with dextrocardia who had undergone pacemaker implantation between January 2006 and July 2013 from a single centre. Six patients with dextrocardia (five males and one female) underwent permanent pacemaker implantation (PPI) between January 2006 and July 2013. Of them, three had situs solitus dextrocardia and three situs inversus dextrocardia. All three patients with situs solitus dextrocardia had associated corrected transposition of great arteries. The indication for pacemaker implantation was symptomatic complete atrioventricular (AV) block in four, high-grade AV block in one, and sinus node dysfunction in one patient. A favourable outcome was noted during a mean follow-up of 3.9 years (4 months to 7 years) with one patient needing a pulse generator replacement. Permanent pacemaker implantation in dextrocardia can be challenging because of the distorted anatomy. Use of a technique employing angiography to delineate chamber anatomy and relationship can assist the operator during such difficult PPIs. The medium- and long-term survival after a successful pacemaker implantation in dextrocardia is favourable. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  18. Cochlear implantation in Mondini's deformity: could the straight electrode array with length of 31 mm be fully inserted?

    Science.gov (United States)

    Sun, Jia-Qiang; Sun, Jing-Wu; Hou, Xiao-Yan

    2017-07-01

    The straight electrode array with length of 31 mm can be fully inserted using round window insertion in cochlear implantation with Mondini's deformity. It is a safe and effective process, but also a challenging task of the full implantation in children with Mondini's deformity. The aim of this study is to discuss whether the straight electrode array with a length of 31 mm could be fully inserted in cochlear implantation with Mondini's deformity. A chart review of 30 patients undergoing cochlear implantation with Mondini's deformity using the electrode array with length of 31 mm was undertaken from January 2012 and December 2015 in Anhui Provincial Hospital. Full insertion of the straight electrode array with length of 31 mm were performed successfully in all patients with Mondini's deformity using round window insertion. Resistance was not encountered while introducing the electrodes. Ten of 30 patients had cerebrospinal fluid drainage during cochlear implantation. Cerebrospinal fluid drainage was controlled with small pieces of temporalis fascia packing round window in all patients. Intra-operative neural response telemetry was performed in all patients, and results were good. The result of X-ray showed proper placement of the cochlear implant electrode array. During surgery, no patients had experienced any immediate or delayed post-operative complications such as wound infection, intracranial complication, extrusion, or migration of the implant during an average follow-up period of 6-36 months.

  19. Troponin T elevation after permanent pacemaker implantation.

    Science.gov (United States)

    Chen, Xueying; Yu, Ziqing; Bai, Jin; Hu, Shulan; Wang, Wei; Qin, Shengmei; Wang, Jingfeng; Sun, Zhe; Su, Yangang; Ge, Junbo

    2017-08-01

    The objective of the study is to study the incidence, significance, and factors associated with cardiac troponin T (CTNT) elevation after pacemaker implantation. Three hundred seventy-four patients (104 single-chamber pacemakers or ICD, 243 dual-chamber pacemakers, and 27 cardiac resynchronization therapy/cardiac resynchronization therapy defibrillator) who had normal levels of CTNT at baseline and underwent implantation of a permanent pacemaker system were included in this study. Serum levels of CTNT were measured at baseline, 6 and 24 h after the implantation procedure. The median of CTNT levels increased from 0.012 ng/mL at baseline to 0.032 and 0.019 ng/mL at 6 and 24 h after the procedure, respectively (all p 0.09 ng/mL). After 1-year follow-up, the incidence of complications including dislodgement of the lead, pocket infection, pneumothorax, hemothorax, and vein thrombus and cardiac outcomes including hospitalization of heart failure, coronary artery disease, arrhythmia, and cardiovascular mortality was not significantly different between the normal and elevated CTNT groups at 6 h after the procedure. By logistic regression analysis, gender, N-terminal pro-B type natriuretic peptide (NT-pro-BNP) at baseline, left ventricular ejection fractions (LVEF), estimated glomerular filtration rate (eGFR), and fluoroscopy time were independently associated with CTNT elevation after adjusted for age, pacemaker types, right ventricle lead location (RVA or RVOT), heart function, and left ventricular end systolic dimension. Pacemaker implantation was found to be accompanied with CTNT elevation in 55.6% of the patients at 6 h after the procedure, and its kinetics were fast, which might not be related to the complications and adverse cardiac outcomes within 1 year of follow-up. Moreover, gender, NT-pro-BNP at baseline, LVEF, eGFR, and fluoroscopy time were found to be independent predictors of CTNT elevation.

  20. 78 FR 41125 - Interim Enforcement Policy for Permanent Implant Brachytherapy Medical Event Reporting

    Science.gov (United States)

    2013-07-09

    ... NUCLEAR REGULATORY COMMISSION [NRC-2013-0114] Interim Enforcement Policy for Permanent Implant Brachytherapy Medical Event Reporting AGENCY: Nuclear Regulatory Commission. ACTION: Policy statement; revision. SUMMARY: The U.S. Nuclear Regulatory Commission (NRC) is issuing an interim Enforcement Policy that allows...

  1. Factors Affecting Outcomes in Cochlear Implant Recipients Implanted With a Perimodiolar Electrode Array Located in Scala Tympani.

    Science.gov (United States)

    Holden, Laura K; Firszt, Jill B; Reeder, Ruth M; Uchanski, Rosalie M; Dwyer, Noël Y; Holden, Timothy A

    2016-12-01

    To identify primary biographic and audiologic factors contributing to cochlear implant (CI) performance variability in quiet and noise by controlling electrode array type and electrode position within the cochlea. Although CI outcomes have improved over time, considerable outcome variability still exists. Biographic, audiologic, and device-related factors have been shown to influence performance. Examining CI recipients with consistent array type and electrode position may allow focused investigation into outcome variability resulting from biographic and audiologic factors. Thirty-nine adults (40 ears) implanted for at least 6 months with a perimodiolar electrode array known (via computed tomography [CT] imaging) to be in scala tympani participated. Test materials, administered CI only, included monosyllabic words, sentences in quiet and noise, and spectral ripple discrimination. In quiet, scores were high with mean word and sentence scores of 76 and 87%, respectively; however, sentence scores decreased by an average of 35 percentage points when noise was added. A principal components (PC) analysis of biographic and audiologic factors found three distinct factors, PC1 Age, PC2 Duration, and PC3 Pre-op Hearing. PC1 Age was the only factor that correlated, albeit modestly, with speech recognition in quiet and noise. Spectral ripple discrimination strongly correlated with speech measures. For these recipients with consistent electrode position, PC1 Age was related to speech recognition performance. Consistent electrode position may have contributed to high speech understanding in quiet. Inter-subject variability in noise may have been influenced by auditory/cognitive processing, known to decline with age, and mechanisms that underlie spectral resolution ability.

  2. Ultra-nanocrystalline diamond electrodes: optimization towards neural stimulation applications.

    Science.gov (United States)

    Garrett, David J; Ganesan, Kumaravelu; Stacey, Alastair; Fox, Kate; Meffin, Hamish; Prawer, Steven

    2012-02-01

    Diamond is well known to possess many favourable qualities for implantation into living tissue including biocompatibility, biostability, and for some applications hardness. However, conducting diamond has not, to date, been exploited in neural stimulation electrodes due to very low electrochemical double layer capacitance values that have been previously reported. Here we present electrochemical characterization of ultra-nanocrystalline diamond electrodes grown in the presence of nitrogen (N-UNCD) that exhibit charge injection capacity values as high as 163 µC cm(-2) indicating that N-UNCD is a viable material for microelectrode fabrication. Furthermore, we show that the maximum charge injection of N-UNCD can be increased by tailoring growth conditions and by subsequent electrochemical activation. For applications requiring yet higher charge injection, we show that N-UNCD electrodes can be readily metalized with platinum or iridium, further increasing charge injection capacity. Using such materials an implantable neural stimulation device fabricated from a single piece of bio-permanent material becomes feasible. This has significant advantages in terms of the physical stability and hermeticity of a long-term bionic implant.

  3. Durability of Hearing Preservation after Cochlear Implantation with Conventional-Length Electrodes and Scala Tympani Insertion.

    Science.gov (United States)

    Sweeney, Alex D; Hunter, Jacob B; Carlson, Matthew L; Rivas, Alejandro; Bennett, Marc L; Gifford, Rene H; Noble, Jack H; Haynes, David S; Labadie, Robert F; Wanna, George B

    2016-05-01

    To analyze factors that influence hearing preservation over time in cochlear implant recipients with conventional-length electrode arrays located entirely within the scala tympani. Case series with planned chart review. Single tertiary academic referral center. A retrospective review was performed to analyze a subgroup of cochlear implant recipients with residual acoustic hearing. Patients were included in the study only if their electrode arrays remained fully in the scala tympani after insertion and serviceable acoustic hearing (≤80 dB at 250 Hz) was preserved. Electrode array location was verified through a validated radiographic assessment tool. Patients with scala tympani. In this group, the style of electrode array may influence residual hearing preservation over time. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  4. Postimplantation Analysis Enables Improvement of Dose-Volume Histograms and Reduction of Toxicity for Permanent Seed Implantation

    International Nuclear Information System (INIS)

    Wust, Peter; Postrach, Johanna; Kahmann, Frank; Henkel, Thomas; Graf, Reinhold; Cho, Chie Hee; Budach, Volker; Boehmer, Dirk

    2008-01-01

    Purpose: To demonstrate how postimplantation analysis is useful for improving permanent seed implantation and reducing toxicity. Patients and Methods: We evaluated 197 questionnaires completed by patients after permanent seed implantation (monotherapy between 1999 and 2003). For 70% of these patients, a computed tomography was available to perform postimplantation analysis. The index doses and volumes of the dose-volume histograms (DVHs) were determined and categorized with respect to the date of implantation. Differences in symptom scores relative to pretherapeutic status were analyzed with regard to follow-up times and DVH descriptors. Acute and subacute toxicities in a control group of 117 patients from an earlier study (June 1999 to September 2001) by Wust et al. (2004) were compared with a matched subgroup from this study equaling 110 patients treated between October 2001 and August 2003. Results: Improved performance, identifying a characteristic time dependency of DVH parameters (after implantation) and toxicity scores, was demonstrated. Although coverage (volume covered by 100% of the prescription dose of the prostate) increased slightly, high-dose regions decreased with the growing experience of the users. Improvement in the DVH and a reduction of toxicities were found in the patient group implanted in the later period. A decline in symptoms with follow-up time counteracts this gain of experience and must be considered. Urinary and sexual discomfort was enhanced by dose heterogeneities (e.g., dose covering 10% of the prostate volume, volume covered by 200% of prescription dose). In contrast, rectal toxicities correlated with exposed rectal volumes, especially the rectal volume covered by 100% of the prescription dose. Conclusion: The typical side effects occurring after permanent seed implantation can be reduced by improving the dose distributions. An improvement in dose distributions and a reduction of toxicities were identified with elapsed time between

  5. Implantable optical-electrode device for stimulation of spinal motoneurons

    International Nuclear Information System (INIS)

    Matveev, M V; Erofeev, A I; Zakharova, O A; Vlasova, O L; Pyatyshev, E N; Kazakin, A N

    2016-01-01

    Recent years, optogenetic method of scientific research has proved its effectiveness in the nerve cell stimulation tasks. In our article we demonstrate an implanted device for the spinal optogenetic motoneurons activation. This work is carried out in the Laboratory of Molecular Neurodegeneration of the Peter the Great St. Petersburg Polytechnic University, together with Nano and Microsystem Technology Laboratory. The work of the developed device is based on the principle of combining fiber optic light stimulation of genetically modified cells with the microelectrode multichannel recording of neurons biopotentials. The paper presents a part of the electrode implant manufacturing technique, combined with the optical waveguide of ThorLabs (USA). (paper)

  6. Initial Operative Experience and Short-term Hearing Preservation Results With a Mid-scala Cochlear Implant Electrode Array.

    Science.gov (United States)

    Svrakic, Maja; Roland, J Thomas; McMenomey, Sean O; Svirsky, Mario A

    2016-12-01

    To describe our initial operative experience and hearing preservation results with the Advanced Bionics (AB) Mid Scala Electrode (MSE). Retrospective review. Tertiary referral center. Sixty-three MSE implants in pediatric and adult patients were compared with age- and sex-matched 1j electrode implants from the same manufacturer. All patients were severe to profoundly deaf. Cochlear implantation with either the AB 1j electrode or the AB MSE. The MSE and 1j electrodes were compared in their angular depth of insertion and pre to postoperative change in hearing thresholds. Hearing preservation was analyzed as a function of angular depth of insertion. Secondary outcome measures included operative time, incidence of abnormal intraoperative impedance and telemetry values, and incidence of postsurgical complications. Depth of insertion was similar for both electrodes, but was more consistent for the MSE array and more variable for the 1j array. Patients with MSE electrodes had better hearing preservation. Thresholds shifts at four audiometric frequencies ranging from 250 to 2000 Hz were 10, 7, 2, and 6 dB smaller for the MSE electrode than for the 1j (p < 0.05). Hearing preservation at low frequencies was worse with deeper insertion, regardless of array. Secondary outcome measures were similar for both electrodes. The MSE electrode resulted in more consistent insertion depth and somewhat better hearing preservation than the 1j electrode. Differences in other surgical outcome measures were small or unlikely to have a meaningful effect.

  7. Virtual electrodes for high-density electrode arrays

    Science.gov (United States)

    Cela, Carlos J.; Lazzi, Gianluca

    2015-10-13

    The present embodiments are directed to implantable electrode arrays having virtual electrodes. The virtual electrodes may improve the resolution of the implantable electrode array without the burden of corresponding complexity of electronic circuitry and wiring. In a particular embodiment, a virtual electrode may include one or more passive elements to help steer current to a specific location between the active electrodes. For example, a passive element may be a metalized layer on a substrate that is adjacent to, but not directly connected to an active electrode. In certain embodiments, an active electrode may be directly coupled to a power source via a conductive connection. Beneficially, the passive elements may help to increase the overall resolution of the implantable array by providing additional stimulation points without requiring additional wiring or driver circuitry for the passive elements.

  8. High resolution micro-CT scanning as an innovative tool for evaluation of the surgical positioning of cochlear implant electrodes.

    Science.gov (United States)

    Postnov, A; Zarowski, A; De Clerck, N; Vanpoucke, F; Offeciers, F E; Van Dyck, D; Peeters, S

    2006-05-01

    X-ray microtomography (micro-CT) is a new technique allowing for visualization of the internal structure of opaque specimens with a quasi-histological quality. Among multiple potential applications, the use of this technique in otology is very promising. Micro-CT appears to be ideally suited for in vitro visualization of the inner ear tissues as well as for evaluation of the electrode damage and/or surgical insertion trauma during implantation of the cochlear implant electrodes. This technique can greatly aid in design and development of new cochlear implant electrodes and is applicable for temporal bone studies. The main advantage of micro-CT is the practically artefact-free preparation of the samples and the possibility of evaluation of the interesting parameters along the whole insertion depth of the electrode. This paper presents the results of the first application of micro-CT for visualization of the inner ear structures in human temporal bones and for evaluation of the surgical positioning of the cochlear implant electrodes relative to the intracochlear soft tissues.

  9. Preoperative CT analysis of the mandible and maxilla for permanent dental prosthetic implantation

    International Nuclear Information System (INIS)

    Rothman, S.L.G.; Rhodes, M.L.; Schwarz, M.; Chafetz, N.I.

    1987-01-01

    The Branemark technique for permanently implanting dental prostheses is becoming universally accepted. The surgeon requires detailed knowledge of the cross-sectional anatomy of the alveolar ridges and inferior alveolar nerve for safe placement of the titanium fixtures. Axial CT scans of the mandible and maxilla, with oblique and panoramic CT reformations, were obtained in more than 100 patients. This report describes the anatomic variations in the maxilla and mandible as they relate to dental implantation surgery. The authors demonstrate the utility of this technique in preoperative surgical planning and postoperative evaluation

  10. Short- and long-term need for permanent pacemaker after transcatheter implantation of the Edwards Sapien aortic valve prosthesis.

    Science.gov (United States)

    Moreno, Raúl; Calvo, Luis; Sánchez-Recalde, Angel; Galeote, Guillermo; Jiménez-Valero, Santiago; López, Teresa; Plaza, Ignacio; González-Davia, Rosa; Ramírez, Ulises; Mesa, Jose Maria; Moreno-Gomez, Isidro; López-Sendón, José-Luis

    2015-11-01

    A permanent pacemaker is frequently needed after transcatheter aortic valve implantation, but the available data are mainly on the CoreValve system. To evaluate the need for new permanent pacemaker after implantation of the Edwards Sapien device, as well as related factors. We included the first 100 patients treated with the Edwards Sapien device at our institution. Of these, 12 had a permanent pacemaker before the procedure, and thus our study population was the remaining 88 patients. A permanent pacemaker was indicated in eight patients (9.1%) during hospitalization or at 30 days. After discharge, another four patients needed a pacemaker (at 42 days and three, 18, and 30 months). Two variables were associated with the need for pacemaker during hospitalization: previous dialysis (13% vs. 1%, p=0.042) and complete right bundle branch block before the procedure (25% vs. 5%, p=0.032). More than one month after the procedure, the characteristics associated with the need for pacemaker were plasma creatinine level (2.5±1.7 vs. 1.3±0.6 mg/dl, p=0.001) and previous myocardial infarction (50% vs. 10%, p=0.013). The rate of pacemaker implantation with the Edwards Sapien device was 9.1%. Right bundle branch block and dialysis were associated with this complication.

  11. Improving Impedance of Implantable Microwire Multi-Electrode Arrays by Ultrasonic Electroplating of Durable Platinum Black

    Science.gov (United States)

    Desai, Sharanya Arcot; Rolston, John D.; Guo, Liang; Potter, Steve M.

    2010-01-01

    Implantable microelectrode arrays (MEAs) have been a boon for neural stimulation and recording experiments. Commercially available MEAs have high impedances, due to their low surface area and small tip diameters, which are suitable for recording single unit activity. Lowering the electrode impedance, but preserving the small diameter, would provide a number of advantages, including reduced stimulation voltages, reduced stimulation artifacts and improved signal-to-noise ratio. Impedance reductions can be achieved by electroplating the MEAs with platinum (Pt) black, which increases the surface area but has little effect on the physical extent of the electrodes. However, because of the low durability of Pt black plating, this method has not been popular for chronic use. Sonicoplating (i.e. electroplating under ultrasonic agitation) has been shown to improve the durability of Pt black on the base metals of macro-electrodes used for cyclic voltammetry. This method has not previously been characterized for MEAs used in chronic neural implants. We show here that sonicoplating can lower the impedances of microwire multi-electrode arrays (MMEA) by an order of magnitude or more (depending on the time and voltage of electroplating), with better durability compared to pulsed plating or traditional DC methods. We also show the improved stimulation and recording performance that can be achieved in an in vivo implantation study with the sonicoplated low-impedance MMEAs, compared to high-impedance unplated electrodes. PMID:20485478

  12. Permanent interstitial implantation of 125Iodine seed for thoracic malignant tumors

    International Nuclear Information System (INIS)

    Xu Zhongheng; Qian Yongyue; Wu Jinchang; Liu Zengli

    2002-01-01

    Objective: To observe effect of 125 Iodine sed on interstitial brachytherapy of patient with thoracic malignant tumor. Methods: 125 Iodine seed were inserted into the target tissue and permanent left there for brachytherapy in 6 cases of thoracic malignant tumors, which including lung cancer, Pancoast's tumour, mediastinal malignant schwannoma. Results: All cases were rehabilitated shortly after operation. The implanted lesions remained controlled now and in dead patients. No radiation-related and 125 Iodine seed-related complications occurred. Conclusion: Brachytherapy by implantation of 125 Iodine seeds of remained tumor tissue in patients with thoracic malignant tumor after operation has a satisfactory outcome. This therapy can control local recurrent of thoracic malignant tumor. But the results in long term should be studied further

  13. Initial Operative Experience and Short Term Hearing Preservation Results with a Mid-Scala Cochlear Implant Electrode Array

    Science.gov (United States)

    Svrakic, Maja; Roland, J. Thomas; McMenomey, Sean O.; Svirsky, Mario A.

    2016-01-01

    OBJECTIVE To describe our initial operative experience and hearing preservation results with the Advanced Bionics (AB) Mid Scala Electrode (MSE) STUDY DESIGN Retrospective review. SETTING Tertiary referral center. PATIENTS Sixty-three MSE implants in pediatric and adult patients were compared to age- and gender-matched 1j electrode implants from the same manufacturer. All patients were severe to profoundly deaf. INTERVENTION Cochlear implantation with either the AB 1j electrode or the AB MSE. MAIN OUTCOME MEASURES The MSE and 1j electrode were compared in their angular depth of insertion (aDOI) and pre- to post-operative change in hearing thresholds. Hearing preservation was analyzed as a function of aDOI. Secondary outcome measures included operative time, incidence of abnormal intraoperative impedance and telemetry values, and incidence of postsurgical complications. RESULTS Depth of insertion was similar for both electrodes, but was more consistent for the MSE array and more variable for the 1j array. Patients with MSE electrodes had better hearing preservation. Thresholds shifts at four audiometric frequencies ranging from 250 to 2,000 Hz were 10 dB, 7 dB, 2 dB and 6 dB smaller for the MSE electrode than for the 1j (p<0.05). Hearing preservation at low frequencies was worse with deeper insertion, regardless of array. Secondary outcome measures were similar for both electrodes. CONCLUSIONS The MSE electrode resulted in more consistent insertion depth and somewhat better hearing preservation than the 1j electrode. Differences in other surgical outcome measures were small or unlikely to have a meaningful effect. PMID:27755356

  14. Percutaneously injectable fetal pacemaker: electrodes, mechanical design and implantation.

    Science.gov (United States)

    Zhou, Li; Chmait, Ramen; Bar-Cohen, Yaniv; Peck, Raymond A; Loeb, Gerald E

    2012-01-01

    We are developing a self-contained cardiac pacemaker with a small, cylindrical shape (~3 × 20 mm) that permits it to be implanted percutaneously into a fetus to treat complete heart block and consequent hydrops fetalis, which is otherwise fatal. The device uses off-the-shelf components including a rechargeable lithium cell and a highly efficient relaxation oscillator encapsulated in epoxy and glass. A corkscrew electrode made from activated iridium can be screwed into the myocardium, followed by release of the pacemaker and a short, flexible lead entirely within the chest of the fetus to avoid dislodgement from fetal movement. The feasibility of implanting the device percutaneously under ultrasonic imaging guidance was demonstrated in acute adult rabbit experiments.

  15. A Strange Case of Downward Displacement of a Deep Brain Stimulation Electrode 10 Years Following Implantation: The Gliding Movement of Snakes Theory.

    Science.gov (United States)

    Iacopino, Domenico Gerardo; Maugeri, Rosario; Giugno, Antonella; Giller, Cole A

    2015-08-01

    Despite the best efforts to ensure stereotactic precision, deep brain stimulation (DBS) electrodes can wander from their intended position after implantation. We report a case of downward electrode migration 10 years following successful implantation in a patient with Parkinson disease. A 53-year-old man with Parkinson disease underwent bilateral implantation of DBS electrodes connected to a subclavicular 2-channel pulse generator. The generator was replaced 7 years later, and a computed tomography (CT) scan confirmed the correct position of both leads. The patient developed a gradual worsening affecting his right side 3 years later, 10 years after the original implantation. A CT scan revealed displacement of the left electrode inferiorly into the pons. The new CT scans and the CT scans obtained immediately after the implantation were merged within a stereotactic planning workstation (Brainlab). Comparing the CT scans, the distal end of the electrode was in the same position, the proximal tip being significantly more inferior. The size and configuration of the coiled portions of the electrode had not changed. At implantation, the length was 27.7 cm; after 10 years, the length was 30.6 cm. These data suggests that the electrode had been stretched into its new position rather than pushed. Clinicians evaluating patients with a delayed worsening should be aware of this rare event. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Investigation of Implantable Multi-Channel Electrode Array in Rat Cerebral Cortex Used for Recording

    Science.gov (United States)

    Taniguchi, Noriyuki; Fukayama, Osamu; Suzuki, Takafumi; Mabuchi, Kunihiko

    There have recently been many studies concerning the control of robot movements using neural signals recorded from the brain (usually called the Brain-Machine interface (BMI)). We fabricated implantable multi-electrode arrays to obtain neural signals from the rat cerebral cortex. As any multi-electrode array should have electrode alignment that minimizes invasion, it is necessary to customize the recording site. We designed three types of 22-channel multi-electrode arrays, i.e., 1) wide, 2) three-layered, and 3) separate. The first extensively covers the cerebral cortex. The second has a length of 2 mm, which can cover the area of the primary motor cortex. The third array has a separate structure, which corresponds to the position of the forelimb and hindlimb areas of the primary motor cortex. These arrays were implanted into the cerebral cortex of a rat. We estimated the walking speed from neural signals using our fabricated three-layered array to investigate its feasibility for BMI research. The neural signal of the rat and its walking speed were simultaneously recorded. The results revealed that evaluation using either the anterior electrode group or posterior group provided accurate estimates. However, two electrode groups around the center yielded poor estimates although it was possible to record neural signals.

  17. Assessment of wrought ASTM F1058 cobalt alloy properties for permanent surgical implants.

    Science.gov (United States)

    Clerc, C O; Jedwab, M R; Mayer, D W; Thompson, P J; Stinson, J S

    1997-01-01

    The behavior of the ASTM F1058 wrought cobalt-chromium-nickel-molybdenum-iron alloy (commonly referred to as Elgiloy or Phynox) is evaluated in terms of mechanical properties, magnetic resonance imaging, corrosion resistance, and biocompatibility. The data found in the literature, the experimental corrosion and biocompatibility results presented in this article, and its long track record as an implant material demonstrate that the cobalt superalloy is an appropriate material for permanent surgical implants that require high yield strength and fatigue resistance combined with high elastic modulus, and that it can be safely imaged with magnetic resonance.

  18. Impedance Changes and Fibrous Tissue Growth after Cochlear Implantation Are Correlated and Can Be Reduced Using a Dexamethasone Eluting Electrode.

    Directory of Open Access Journals (Sweden)

    Maciej Wilk

    Full Text Available The efficiency of cochlear implants (CIs is affected by postoperative connective tissue growth around the electrode array. This tissue formation is thought to be the cause behind post-operative increases in impedance. Dexamethasone (DEX eluting CIs may reduce fibrous tissue growth around the electrode array subsequently moderating elevations in impedance of the electrode contacts.For this study, DEX was incorporated into the silicone of the CI electrode arrays at 1% and 10% (w/w concentration. Electrodes prepared by the same process but without dexamethasone served as controls. All electrodes were implanted into guinea pig cochleae though the round window membrane approach. Potential additive or synergistic effects of electrical stimulation (60 minutes were investigated by measuring impedances before and after stimulation (days 0, 7, 28, 56 and 91. Acoustically evoked auditory brainstem responses were recorded before and after CI insertion as well as on experimental days 7, 28, 56, and 91. Additionally, histology performed on epoxy embedded samples enabled measurement of the area of scala tympani occupied with fibrous tissue.In all experimental groups, the highest levels of fibrous tissue were detected in the basal region of the cochlea in vicinity to the round window niche. Both DEX concentrations, 10% and 1% (w/w, significantly reduced fibrosis around the electrode array of the CI. Following 3 months of implantation impedance levels in both DEX-eluting groups were significantly lower compared to the control group, the 10% group producing a greater effect. The same effects were observed before and after electrical stimulation.To our knowledge, this is the first study to demonstrate a correlation between the extent of new tissue growth around the electrode and impedance changes after cochlear implantation. We conclude that DEX-eluting CIs are a means to reduce this tissue reaction and improve the functional benefits of the implant by attenuating

  19. Combined use of transcranial magnetic stimulation and metal electrode implants: a theoretical assessment of safety considerations

    Science.gov (United States)

    Golestanirad, Laleh; Rouhani, Hossein; Elahi, Behzad; Shahim, Kamal; Chen, Robert; Mosig, Juan R.; Pollo, Claudio; Graham, Simon J.

    2012-12-01

    This paper provides a theoretical assessment of the safety considerations encountered in the simultaneous use of transcranial magnetic stimulation (TMS) and neurological interventions involving implanted metallic electrodes, such as electrocorticography. Metal implants are subject to magnetic forces due to fast alternating magnetic fields produced by the TMS coil. The question of whether the mechanical movement of the implants leads to irreversible damage of brain tissue is addressed by an electromagnetic simulation which quantifies the magnitude of imposed magnetic forces. The assessment is followed by a careful mechanical analysis determining the maximum tolerable force which does not cause irreversible tissue damage. Results of this investigation provide useful information on the range of TMS stimulator output powers which can be safely used in patients having metallic implants. It is shown that conventional TMS applications can be considered safe when applied on patients with typical electrode implants as the induced stress in the brain tissue remains well below the limit of tissue damage.

  20. Electrical characteristic of the titanium mesh electrode for transcutaneous intrabody communication to monitor implantable artificial organs.

    Science.gov (United States)

    Okamoto, Eiji; Kikuchi, Sakiko; Mitamura, Yoshinori

    2016-09-01

    We have developed a tissue-inducing electrode using titanium mesh to obtain mechanically and electrically stable contact with the tissue for a new transcutaneous communication system using the human body as a conductive medium. In this study, we investigated the electrical properties of the titanium mesh electrode by measuring electrode-tissue interface resistance in vivo. The titanium mesh electrode (Hi-Lex Co., Zellez, Hyogo, Japan) consisted of titanium fibers (diameter of 50 μm), and it has an average pore size of 200 μm and 87 % porosity. The titanium mesh electrode has a diameter of 5 mm and thickness of 1.5 mm. Three titanium mesh electrodes were implanted separately into the dorsal region of the rat. We measured the electrode-electrode impedance using an LCR meter for 12 weeks, and we calculated the tissue resistivity and electrode-tissue interface resistance. The electrode-tissue interface resistance of the titanium mesh electrode decreased slightly until the third POD and then continuously increased to 75 Ω. The electrode-tissue interface resistance of the titanium mesh electrode is stable and it has lower electrode-tissue interface resistance than that of a titanium disk electrode. The extracted titanium mesh electrode after 12 weeks implantation was fixed in 10 % buffered formalin solution and stained with hematoxylin-eosin. Light microscopic observation showed that the titanium mesh electrode was filled with connective tissue, inflammatory cells and fibroblasts with some capillaries in the pores of the titanium mesh. The results indicate that the titanium mesh electrode is a promising electrode for the new transcutaneous communication system.

  1. A surgical robot with augmented reality visualization for stereoelectroencephalography electrode implantation.

    Science.gov (United States)

    Zeng, Bowei; Meng, Fanle; Ding, Hui; Wang, Guangzhi

    2017-08-01

    Using existing stereoelectroencephalography (SEEG) electrode implantation surgical robot systems, it is difficult to intuitively validate registration accuracy and display the electrode entry points (EPs) and the anatomical structure around the electrode trajectories in the patient space to the surgeon. This paper proposes a prototype system that can realize video see-through augmented reality (VAR) and spatial augmented reality (SAR) for SEEG implantation. The system helps the surgeon quickly and intuitively confirm the registration accuracy, locate EPs and visualize the internal anatomical structure in the image space and patient space. We designed and developed a projector-camera system (PCS) attached to the distal flange of a robot arm. First, system calibration is performed. Second, the PCS is used to obtain the point clouds of the surface of the patient's head, which are utilized for patient-to-image registration. Finally, VAR is produced by merging the real-time video of the patient and the preoperative three-dimensional (3D) operational planning model. In addition, SAR is implemented by projecting the planning electrode trajectories and local anatomical structure onto the patient's scalp. The error of registration, the electrode EPs and the target points are evaluated on a phantom. The fiducial registration error is [Formula: see text] mm (max 1.22 mm), and the target registration error is [Formula: see text] mm (max 1.18 mm). The projection overlay error is [Formula: see text] mm, and the TP error after the pre-warped projection is [Formula: see text] mm. The TP error caused by a surgeon's viewpoint deviation is also evaluated. The presented system can help surgeons quickly verify registration accuracy during SEEG procedures and can provide accurate EP locations and internal structural information to the surgeon. With more intuitive surgical information, the surgeon may have more confidence and be able to perform surgeries with better outcomes.

  2. Challenging aspects of contemporary cochlear implant electrode array design.

    Science.gov (United States)

    Mistrík, Pavel; Jolly, Claude; Sieber, Daniel; Hochmair, Ingeborg

    2017-12-01

    A design comparison of current perimodiolar and lateral wall electrode arrays of the cochlear implant (CI) is provided. The focus is on functional features such as acoustic frequency coverage and tonotopic mapping, battery consumption and dynamic range. A traumacity of their insertion is also evaluated. Review of up-to-date literature. Perimodiolar electrode arrays are positioned in the basal turn of the cochlea near the modiolus. They are designed to initiate the action potential in the proximity to the neural soma located in spiral ganglion. On the other hand, lateral wall electrode arrays can be inserted deeper inside the cochlea, as they are located along the lateral wall and such insertion trajectory is less traumatic. This class of arrays targets primarily surviving neural peripheral processes. Due to their larger insertion depth, lateral wall arrays can deliver lower acoustic frequencies in manner better corresponding to cochlear tonotopicity. In fact, spiral ganglion sections containing auditory nerve fibres tuned to low acoustic frequencies are located deeper than 1 and half turn inside the cochlea. For this reason, a significant frequency mismatch might be occurring for apical electrodes in perimodiolar arrays, detrimental to speech perception. Tonal languages such as Mandarin might be therefore better treated with lateral wall arrays. On the other hand, closer proximity to target tissue results in lower psychophysical threshold levels for perimodiolar arrays. However, the maximal comfort level is also lower, paradoxically resulting in narrower dynamic range than that of lateral wall arrays. Battery consumption is comparable for both types of arrays. Lateral wall arrays are less likely to cause trauma to cochlear structures. As the current trend in cochlear implantation is the maximal protection of residual acoustic hearing, the lateral wall arrays seem more suitable for hearing preservation CI surgeries. Future development could focus on combining the

  3. Cochlear Implant Electrode Localization Using an Ultra-High Resolution Scan Mode on Conventional 64-Slice and New Generation 192-Slice Multi-Detector Computed Tomography.

    Science.gov (United States)

    Carlson, Matthew L; Leng, Shuai; Diehn, Felix E; Witte, Robert J; Krecke, Karl N; Grimes, Josh; Koeller, Kelly K; Bruesewitz, Michael R; McCollough, Cynthia H; Lane, John I

    2017-08-01

    A new generation 192-slice multi-detector computed tomography (MDCT) clinical scanner provides enhanced image quality and superior electrode localization over conventional MDCT. Currently, accurate and reliable cochlear implant electrode localization using conventional MDCT scanners remains elusive. Eight fresh-frozen cadaveric temporal bones were implanted with full-length cochlear implant electrodes. Specimens were subsequently scanned with conventional 64-slice and new generation 192-slice MDCT scanners utilizing ultra-high resolution modes. Additionally, all specimens were scanned with micro-CT to provide a reference criterion for electrode position. Images were reconstructed according to routine temporal bone clinical protocols. Three neuroradiologists, blinded to scanner type, reviewed images independently to assess resolution of individual electrodes, scalar localization, and severity of image artifact. Serving as the reference standard, micro-CT identified scalar crossover in one specimen; imaging of all remaining cochleae demonstrated complete scala tympani insertions. The 192-slice MDCT scanner exhibited improved resolution of individual electrodes (p implant imaging compared with conventional MDCT. This technology provides important feedback regarding electrode position and course, which may help in future optimization of surgical technique and electrode design.

  4. [TRENDS OF PERMANENT PACEMAKER IMPLANTATION IN A SINGLE CENTER OVER A 20-YEAR PERIOD].

    Science.gov (United States)

    Antonelli, Dante; Ilan, Limor Bushar; Freedberg, Nahum A; Feldman, Alexander; Turgeman, Yoav

    2015-05-01

    To review the changes in permanent pacemaker implantation indications, pacing modes and patients' demographics over a 20-year period. We retrospectively retrieved data on patients who underwent first implantation of the pacemaker between 1-1-1991 and 31-12-2010. One thousand and nine (1,009) patients underwent a first pacemaker implantation during that period; 535 were men (53%), their mean age was 74.6±19.5 years; the highest rate of implanted pacemaker was in patients ranging in age from 70-79 years, however there was an increasing number of patients aged over 80 years. The median survival time after initial pacemaker implantation was 8 years. Syncope was the most common symptom (62.5%) and atrioventricular block was the most common electrocardiographic indication (56.4%) leading to pacemaker implantation. There was increased utilization of dual chamber and rate responsive pacemakers over the years. There was no difference regarding mode selection between genders. Pacemaker implantation rates have increased over a 20-year period. Dual chamber replaced most of the single ventricular chamber pacemaker and rate responsive pacemakers became the norm. The data of a small volume center are similar to those reported in pacemaker surveys of high volume pacemaker implantation centers. They confirm adherence to the published guidelines for pacing.

  5. Echocardiography-guided Radiofrequency Catheter Ablation of Atrioventricular Node and VVI Pacemaker Implantation

    Directory of Open Access Journals (Sweden)

    T Guo

    2014-05-01

    Full Text Available Objective: This study is to evaluate the feasibility and safety of intracardiac radiofrequency catheter ablation (RFCA of the atrioventricular node (AVN and pacemaker implantation using transthoracic echocardiography. Methods: Eleven patients – six males and five females (mean age 66 years – with persistent or permanent atrial fibrillation/atrial flutter received RFCA of AVN and VVI pacemaker implantation (paces and senses the ventricle and is inhibited if it senses ventricular activity. Under transthoracic echocardiography, the electrode catheters were positioned intracardiac, and target ablation was performed, with the permanent pacemaking catheter in the left subclavian vein and the ablation catheter in the right femoral vein. The multi-view imaging and dynamic observation applied during the stable AV dissociation were successful. Results: Atrioventricular node ablation and permanent pacemaker implantation in 11 patients were completed successfully without X-ray exposure. The operation success rate was 100%. All patients recovered well within the follow-up period. Conclusions: Radiofrequency catheter ablation of AVN and VVI pacemaker implantation under transthoracic echocardiography guidance is a safe, easy and feasible approach. This procedure could be an important supplemental measure to catheter ablation of arrhythmia under routine X-ray fluoroscopy.

  6. Finite difference time domain (FDTD) modeling of implanted deep brain stimulation electrodes and brain tissue.

    Science.gov (United States)

    Gabran, S R I; Saad, J H; Salama, M M A; Mansour, R R

    2009-01-01

    This paper demonstrates the electromagnetic modeling and simulation of an implanted Medtronic deep brain stimulation (DBS) electrode using finite difference time domain (FDTD). The model is developed using Empire XCcel and represents the electrode surrounded with brain tissue assuming homogenous and isotropic medium. The model is created to study the parameters influencing the electric field distribution within the tissue in order to provide reference and benchmarking data for DBS and intra-cortical electrode development.

  7. Mechanical fatigue resistance of an implantable branched lead system for a distributed set of longitudinal intrafascicular electrodes

    Science.gov (United States)

    Pena, A. E.; Kuntaegowdanahalli, S. S.; Abbas, J. J.; Patrick, J.; Horch, K. W.; Jung, R.

    2017-12-01

    Objective. A neural interface system has been developed that consists of an implantable stimulator/recorder can with a 15-electrode lead that trifurcates into three bundles of five individual wire longitudinal intrafascicular electrodes. This work evaluated the mechanical fatigue resistance of the branched lead and distributed electrode system under conditions designed to mimic anticipated strain profiles that would be observed after implantation in the human upper arm. Approach. Custom test setups and procedures were developed to apply linear or angular strain at four critical stress riser points on the lead and electrode system. Each test was performed to evaluate fatigue under a high repetition/low amplitude paradigm designed to test the effects of arm movement on the leads during activities such as walking, or under a low repetition/high amplitude paradigm designed to test the effects of more strenuous upper arm activities. The tests were performed on representative samples of the implantable lead system for human use. The specimens were fabricated using procedures equivalent to those that will be used during production of human-use implants. Electrical and visual inspections of all test specimens were performed before and after the testing procedures to assess lead integrity. Main results. Measurements obtained before and after applying repetitive strain indicated that all test specimens retained electrical continuity and that electrical impedance remained well below pre-specified thresholds for detection of breakage. Visual inspection under a microscope at 10×  magnification did not reveal any signs of damage to the wires or silicone sheathing at the stress riser points. Significance. These results demonstrate that the branched lead of this implantable neural interface system has sufficient mechanical fatigue resistance to withstand strain profiles anticipated when the system is implanted in an arm. The novel test setups and paradigms may be useful in

  8. Mechanical fatigue resistance of an implantable branched lead system for a distributed set of longitudinal intrafascicular electrodes.

    Science.gov (United States)

    Pena, A E; Kuntaegowdanahalli, S S; Abbas, J J; Patrick, J; Horch, K W; Jung, R

    2017-12-01

    A neural interface system has been developed that consists of an implantable stimulator/recorder can with a 15-electrode lead that trifurcates into three bundles of five individual wire longitudinal intrafascicular electrodes. This work evaluated the mechanical fatigue resistance of the branched lead and distributed electrode system under conditions designed to mimic anticipated strain profiles that would be observed after implantation in the human upper arm. Custom test setups and procedures were developed to apply linear or angular strain at four critical stress riser points on the lead and electrode system. Each test was performed to evaluate fatigue under a high repetition/low amplitude paradigm designed to test the effects of arm movement on the leads during activities such as walking, or under a low repetition/high amplitude paradigm designed to test the effects of more strenuous upper arm activities. The tests were performed on representative samples of the implantable lead system for human use. The specimens were fabricated using procedures equivalent to those that will be used during production of human-use implants. Electrical and visual inspections of all test specimens were performed before and after the testing procedures to assess lead integrity. Measurements obtained before and after applying repetitive strain indicated that all test specimens retained electrical continuity and that electrical impedance remained well below pre-specified thresholds for detection of breakage. Visual inspection under a microscope at 10×  magnification did not reveal any signs of damage to the wires or silicone sheathing at the stress riser points. These results demonstrate that the branched lead of this implantable neural interface system has sufficient mechanical fatigue resistance to withstand strain profiles anticipated when the system is implanted in an arm. The novel test setups and paradigms may be useful in testing other lead systems.

  9. Safety of repetitive transcranial magnetic stimulation in patients with implanted cortical electrodes. An ex-vivo study and report of a case.

    Science.gov (United States)

    Phielipp, Nicolás M; Saha, Utpal; Sankar, Tejas; Yugeta, Akihiro; Chen, Robert

    2017-06-01

    To evaluate the safety of repetitive transcranial magnetic stimulation (rTMS) in patients with implanted subdural cortical electrodes. We performed ex-vivo experiments to test the temperature, displacement and current induced in the electrodes with single pulse transcranial magnetic stimulation (TMS) from 10 to 100% of stimulator output and tested a typical rTMS protocol used in a clinical setting. We then used rTMS to the motor cortex to treat a patient with refractory post-herpetic neuralgia who had previously been implanted with a subdural motor cortical electrode for pain management. The rTMS protocol consisted of ten sessions of 2000 stimuli at 20Hz and 90% of resting motor threshold. The ex-vivo study showed an increase in the coil temperature of 2°C, a maximum induced charge density of 30.4μC/cm 2 /phase, and no electrode displacement with TMS. There was no serious adverse effect associated with rTMS treatment of the patient. Cortical tremor was observed in the intervals between trains of stimuli during one treatment session. TMS was safe in a patient with implanted Medtronic Resume II electrode (model 3587A) subdural cortical electrode. TMS may be used as a therapeutic, diagnostic or research tool in patients this type of with implanted cortical electrodes. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  10. Dose calculation for permanent prostate implants incorporating spatially anisotropic linearly time-resolving edema

    International Nuclear Information System (INIS)

    Monajemi, T. T.; Clements, Charles M.; Sloboda, Ron S.

    2011-01-01

    Purpose: The objectives of this study were (i) to develop a dose calculation method for permanent prostate implants that incorporates a clinically motivated model for edema and (ii) to illustrate the use of the method by calculating the preimplant dosimetry error for a reference configuration of 125 I, 103 Pd, and 137 Cs seeds subject to edema-induced motions corresponding to a variety of model parameters. Methods: A model for spatially anisotropic edema that resolves linearly with time was developed based on serial magnetic resonance imaging measurements made previously at our center to characterize the edema for a group of n=40 prostate implant patients [R. S. Sloboda et al., ''Time course of prostatic edema post permanent seed implant determined by magnetic resonance imaging,'' Brachytherapy 9, 354-361 (2010)]. Model parameters consisted of edema magnitude, Δ, and period, T. The TG-43 dose calculation formalism for a point source was extended to incorporate the edema model, thus enabling calculation via numerical integration of the cumulative dose around an individual seed in the presence of edema. Using an even power piecewise-continuous polynomial representation for the radial dose function, the cumulative dose was also expressed in closed analytical form. Application of the method was illustrated by calculating the preimplant dosimetry error, RE preplan , in a 5x5x5 cm 3 volume for 125 I (Oncura 6711), 103 Pd (Theragenics 200), and 131 Cs (IsoRay CS-1) seeds arranged in the Radiological Physics Center test case 2 configuration for a range of edema relative magnitudes (Δ=[0.1,0.2,0.4,0.6,1.0]) and periods (T=[28,56,84] d). Results were compared to preimplant dosimetry errors calculated using a variation of the isotropic edema model developed by Chen et al. [''Dosimetric effects of edema in permanent prostate seed implants: A rigorous solution,'' Int. J. Radiat. Oncol., Biol., Phys. 47, 1405-1419 (2000)]. Results: As expected, RE preplan for our edema model

  11. Comparison of MRI pulse sequences in defining prostate volume after permanent implantation

    International Nuclear Information System (INIS)

    McLaughlin, P.W.; Narayana, V.; Drake, D.G.; Miller, B.M.; Marsh, L.; Chan, J.; Gonda, R.; Winfield, R.J.; Roberson, P.L.

    2002-01-01

    Purpose: To determine the relative value of three MRI pulse sequences in defining the prostate volume after permanent implantation. Methods and Materials: A total of 45 patients who received a permanent 125 I implant were studied. Two weeks after implantation, an axial CT scan (2 mm thickness) and T 1 -weighted, T 1 -weighted fat saturation, and T 2 -weighted axial MRI (3-mm) studies were obtained. The prostate volumes were compared with the initial ultrasound planning volumes, and subsequently the CT, T 1 -weighted, and T 1 -weighted fat saturation MRI volumes were compared with the T 2 -weighted volumes. Discrepancies in volume were evaluated by visual inspection of the registered axial images and the registration of axial volumes on the sagittal T 2 -weighted volumes. In a limited set of patients, pre- and postimplant CT and T 2 -weighted MRI studies were available for comparison to determine whether prostate volume changes after implant were dependent on the imaging modality. Results: T 1 -weighted and T 1 -weighted fat saturation MRI and CT prostate volumes were consistently larger than the T 2 -weighted MRI prostate volumes, with a volume on average 1.33 (SD 0.24) times the T 2 -weighted volume. This discrepancy was due to the superiority of T 2 -weighted MRI for prostate definition at the following critical interfaces: membranous urethra, apex, and anterior base-bladder and posterior base-seminal vesicle interfaces. The differences in prostate definition in the anterior base region suggest that the commonly reported underdose may be due to overestimation of the prostate in this region by CT. The consistent difference in volumes suggests that the degree of swelling observed after implantation is in part a function of the imaging modality. In patients with pre- and postimplant CT and T 2 -weighted MRI images, swelling on the T 2 -weighted images was 1.1 times baseline and on CT was 1.3 times baseline, confirming the imaging modality dependence of prostate

  12. Binaural release from masking with single- and multi-electrode stimulation in children with cochlear implants.

    Science.gov (United States)

    Todd, Ann E; Goupell, Matthew J; Litovsky, Ruth Y

    2016-07-01

    Cochlear implants (CIs) provide children with access to speech information from a young age. Despite bilateral cochlear implantation becoming common, use of spatial cues in free field is smaller than in normal-hearing children. Clinically fit CIs are not synchronized across the ears; thus binaural experiments must utilize research processors that can control binaural cues with precision. Research to date has used single pairs of electrodes, which is insufficient for representing speech. Little is known about how children with bilateral CIs process binaural information with multi-electrode stimulation. Toward the goal of improving binaural unmasking of speech, this study evaluated binaural unmasking with multi- and single-electrode stimulation. Results showed that performance with multi-electrode stimulation was similar to the best performance with single-electrode stimulation. This was similar to the pattern of performance shown by normal-hearing adults when presented an acoustic CI simulation. Diotic and dichotic signal detection thresholds of the children with CIs were similar to those of normal-hearing children listening to a CI simulation. The magnitude of binaural unmasking was not related to whether the children with CIs had good interaural time difference sensitivity. Results support the potential for benefits from binaural hearing and speech unmasking in children with bilateral CIs.

  13. Percutaneously Inject able Fetal Pacemaker: Electrodes, Mechanical Design and Implantation*

    Science.gov (United States)

    Zhou, Li; Chmait, Ramen; Bar-Cohen, Yaniv; Peck, Raymond A.; Loeb, Gerald E.

    2015-01-01

    We are developing a self-contained cardiac pacemaker with a small, cylindrical shape (~3×20mm) that permits it to be implanted percutaneously into a fetus to treat complete heart block and consequent hydrops fetalis, which is otherwise fatal. The device uses off-the-shelf components including a rechargeable lithium cell and a highly efficient relaxation oscillator encapsulated in epoxy and glass. A corkscrew electrode made from activated iridium can be screwed into the myocardium, followed by release of the pacemaker and a short, flexible lead entirely within the chest of the fetus to avoid dislodgement from fetal movement. The feasibility of implanting the device percutaneously under ultrasonic imaging guidance was demonstrated in acute adult rabbit experiments. PMID:23367442

  14. Radiologic and functional evaluation of electrode dislocation from the scala tympani to the scala vestibuli in patients with cochlear implants.

    Science.gov (United States)

    Fischer, N; Pinggera, L; Weichbold, V; Dejaco, D; Schmutzhard, J; Widmann, G

    2015-02-01

    Localization of the electrode after cochlear implantation seems to have an impact on auditory outcome, and conebeam CT has emerged as a reliable method for visualizing the electrode array position within the cochlea. The aim of this retrospective study was to evaluate the frequency and clinical impact of scalar dislocation of various electrodes and surgical approaches and to evaluate its influence on auditory outcome. This retrospective single-center study analyzed a consecutive series of 63 cochlear implantations with various straight electrodes. The placement of the electrode array was evaluated by using multiplanar reconstructed conebeam CT images. For the auditory outcome, we compared the aided hearing thresholds and the charge units of maximum comfortable loudness level at weeks 6, 12, and 24 after implantation. In 7.9% of the cases, the electrode array showed scalar dislocation. In all cases, the electrode array penetrated the basal membrane within 45° of the electrode insertion. All 3 cases of cochleostomy were dislocated in the first 45° segment. No hearing differences were noted, but the charge units of maximum comfortable loudness level seemed to increase with time in patients with dislocations. The intracochlear dislocation rate of various straight electrodes detected by conebeam CT images is relatively low. Scalar dislocation may not negatively influence the hearing threshold but may require an increase of the necessary stimulus charge and should be reported by the radiologist. © 2015 by American Journal of Neuroradiology.

  15. An array of highly flexible electrodes with a tailored configuration locked by gelatin during implantation – initial evaluation in cortex cerebri of awake rats

    Directory of Open Access Journals (Sweden)

    Johan eAgorelius

    2015-09-01

    Full Text Available A major challenge in the field of neural interfaces is to overcome the problem of poor stability of neuronal recordings, which impedes long-term studies of individual neurons in the brain. Conceivably, unstable recordings reflect relative movements between electrode and tissue. To address this challenge, we have developed a new ultra-flexible electrode array and evaluated its performance in awake non-restrained animals.MethodsAn array of eight separated gold leads (4 x10 μm, individually flexible in 3D, were cut from a gold sheet using laser milling and insulated with Parylene C. To provide structural support during implantation into rat cortex, the electrode array was embedded in a hard gelatin based material, which dissolves after implantation. Recordings were made during 3 weeks. At termination, the animals were perfused with fixative and frozen to prevent dislocation of the implanted electrodes. A thick slice of brain tissue, with the electrode array still in situ, was made transparent using methyl salicylate to evaluate the conformation of the implanted electrode array.ResultsMedian noise levels and signal/noise remained relatively stable during the 3 week observation period; 4.3 μV to 5.9 μV and 2.8 to 4.2, respectively. The spike amplitudes were often quite stable within recording sessions and for 15% of recordings where single-units were identified, the highest-SNR unit had an amplitude higher than 150 V. In addition, high correlations (>0.96 between unit waveforms recorded at different time points were obtained for 58% of the electrode sites. The structure of the electrode array was well preserved 3 weeks after implantation.Conclusions A new implantable multichannel neural interface, comprising electrodes individually flexible in 3D that retain its architecture and functionality after implantation has been developed. Since the new neural interface design is adaptable, it offers a versatile tool to explore the function of various

  16. Stereotactic iodine-125 brachytherapy for brain tumors: temporary versus permanent implantation

    Directory of Open Access Journals (Sweden)

    Ruge Maximilian I

    2012-06-01

    Full Text Available Abstract Stereotactic brachytherapy (SBT has been described in several publications as an effective, minimal invasive and safe highly focal treatment option in selected patients with well circumscribed brain tumors 40 cGy/h in combination with adjuvant external beam radiation and/or chemotherapy for the treatment of malignant gliomas and metastases resulted in increased rates of radiation induced adverse tissue changes requiring surgical intervention. Vice versa, such effects have been only minimally observed in numerous studies applying low dose rate (LDR regiments (3–8 cGy/h for low grade gliomas, metastases and other rare indications. Besides these observations, there are, however, no data available directly comparing the long term incidences of tissue changes after HDR and LDR and there is, furthermore, no evidence regarding a difference between temporary or permanent LDR implantation schemes. Thus, recommendations for effective and safe implantation schemes have to be investigated and compared in future studies.

  17. [Technique of intraoperative planning in prostatic brachytherapy with permanent implants of 125I or 103Pd].

    Science.gov (United States)

    Prada Gómez, Pedro José; Juan Rijo, Germán; Hevia Suarez, Miguel; Abascal García, José María; Abascal García, Ramón

    2002-12-01

    Prostatic brachytherapy with permanent 125I or 123Pd seeds implantation is a therapeutic option for organ-confined prostate cancer. We analyze the technique based on previous planning, our current intraoperative planning procedure and the reasons that moved us to introduce this change. Changes in prostate volume and spatial localization observed between previous planning and intraoperative images, and possible difficulties for seed implantation due to pubic arch interference are some of the reasons that induce us to change technique. Before the operation, we calculate the prostatic volume by transrectal ultrasound; with this information we determine the total implant activity following Wu's nomogram, and per-seed activity; therefore, it is an individual process for each patient. We perform a peripheral implant, placing 75-80% of the seeds within the peripheral prostatic zone, generally through 12-15 needles, the rest of the seeds are placed in the central prostatic zone using a maximum of 3-4 needles in high volume prostates. The day of intervention, after positioning and catheter insertion, volumetry is re-checked. Ultrasound images (from base to apex every 5 mm) are transferred to the planner were a suitable seed distribution is determined. Implantation is then performed placing all needles unloaded, and then intraoperative post-planning to allow us to check implant precision is performed after cistoscopically check that there is no urethral or bladder penetration by any needle. We finish with the insertion of seeds into the prostate. Total time for the procedure is around 90 minutes. Intraoperative planning is an additional step for the treatment of prostate cancer with permanent seeds brachytherapy, which avoids the disadvantages of previous planning and improves tumor inclusion in the ideal irradiation dose area, which will translate into better local disease control.

  18. Prostatic edema in 125I permanent prostate implants: Dynamical dosimetry taking volume changes into account

    International Nuclear Information System (INIS)

    Leclerc, Ghyslain; Lavallee, Marie-Claude; Roy, Rene; Vigneault, Eric; Beaulieu, Luc

    2006-01-01

    The purpose of this study is to determine the impact of edema on the dose delivered to the target volume. An evaluation of the edema characteristics was first made, and then a dynamical dosimetry algorithm was developed and used to compare its results to a standard clinical (static) dosimetry. Source positions and prostate contours extracted from 66 clinical cases on images taken at different points in time (planning, implant day, post-implant evaluation) were used, via the mean interseed distance, to characterize edema [initial increase (Δr 0 ), half-life (τ)]. An algorithm was developed to take into account the edema by summing a time series of dose-volume histograms (DVHs) with a weight based on the fraction of the dose delivered during the time interval considered. The algorithm was then used to evaluate the impact of edema on the dosimetry of permanent implants by comparing its results to those of a standard clinical dosimetry. The volumetric study yielded results as follows: the initial prostate volume increase was found to be 1.58 (ranging from 1.15 to 2.48) and the edema half-life, approximately 30 days (range: 3 to 170 days). The dosimetric differences in D 90 observed between the dynamic dosimetry and the clinical one for a single case were up to 15 Gy and depended on the edema half-life and the initial volume increase. The average edema half-life, 30 days, is about 3 times longer than the previously reported 9 days. Dosimetric differences up to 10% of the prescription dose are observed, which can lead to differences in the quality assertion of an implant. The study of individual patient edema resorption with time might be necessary to extract meaningful clinical correlation or biological parameters in permanent implants

  19. Cone-beam computed tomography in children with cochlear implants: The effect of electrode array position on ECAP.

    Science.gov (United States)

    Lathuillière, Marine; Merklen, Fanny; Piron, Jean-Pierre; Sicard, Marielle; Villemus, Françoise; Menjot de Champfleur, Nicolas; Venail, Frédéric; Uziel, Alain; Mondain, Michel

    2017-01-01

    To assess the feasibility of using cone-beam computed tomography (CBCT) in young children with cochlear implants (CIs) and study the effect of intracochlear position on electrophysiological and behavioral measurements. A total of 40 children with either unilateral or bilateral cochlear implants were prospectively included in the study. Electrode placement and insertion angles were studied in 55 Cochlear ® implants (16 straight arrays and 39 perimodiolar arrays), using either CBCT or X-ray imaging. CBCT or X-ray imaging were scheduled when the children were leaving the recovery room. We recorded intraoperative and postoperative neural response telemetry threshold (T-NRT) values, intraoperative and postoperative electrode impedance values, as well as behavioral T (threshold) and C (comfort) levels on electrodes 1, 5, 10, 15 and 20. CBCT imaging was feasible without any sedation in 24 children (60%). Accidental scala vestibuli insertion was observed in 3 out of 24 implants as assessed by CBCT. The mean insertion angle was 339.7°±35.8°. The use of a perimodiolar array led to higher angles of insertion, lower postoperative T-NRT, as well as decreased behavioral T and C levels. We found no significant effect of either electrode array position or angle of insertion on electrophysiological data. CBCT appears to be a reliable tool for anatomical assessment of young children with CIs. Intracochlear position had no significant effect on the electrically evoked compound action potential (ECAP) threshold. Our CBCT protocol must be improved to increase the rate of successful investigations. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. WE-AB-BRA-11: Improved Imaging of Permanent Prostate Brachytherapy Seed Implants by Combining an Endorectal X-Ray Sensor with a CT Scanner

    International Nuclear Information System (INIS)

    Steiner, J; Matthews, K; Jia, G

    2016-01-01

    Purpose: To test feasibility of the use of a digital endorectal x-ray sensor for improved image resolution of permanent brachytherapy seed implants compared to conventional CT. Methods: Two phantoms simulating the male pelvic region were used to test the capabilities of a digital endorectal x-ray sensor for imaging permanent brachytherapy seed implants. Phantom 1 was constructed from acrylic plastic with cavities milled in the locations of the prostate and the rectum. The prostate cavity was filled a Styrofoam plug implanted with 10 training seeds. Phantom 2 was constructed from tissue-equivalent gelatins and contained a prostate phantom implanted with 18 strands of training seeds. For both phantoms, an intraoral digital dental x-ray sensor was placed in the rectum within 2 cm of the seed implants. Scout scans were taken of the phantoms over a limited arc angle using a CT scanner (80 kV, 120–200 mA). The dental sensor was removed from the phantoms and normal helical CT and scout (0 degree) scans using typical parameters for pelvic CT (120 kV, auto-mA) were collected. A shift-and add tomosynthesis algorithm was developed to localize seed plane location normal to detector face. Results: The endorectal sensor produced images with improved resolution compared to CT scans. Seed clusters and individual seed geometry were more discernable using the endorectal sensor. Seed 3D locations, including seeds that were not located in every projection image, were discernable using the shift and add algorithm. Conclusion: This work shows that digital endorectal x-ray sensors are a feasible method for improving imaging of permanent brachytherapy seed implants. Future work will consist of optimizing the tomosynthesis technique to produce higher resolution, lower dose images of 1) permanent brachytherapy seed implants for post-implant dosimetry and 2) fine anatomic details for imaging and managing prostatic disease compared to CT images. Funding: LSU Faculty Start-up Funding

  1. WE-AB-BRA-11: Improved Imaging of Permanent Prostate Brachytherapy Seed Implants by Combining an Endorectal X-Ray Sensor with a CT Scanner

    Energy Technology Data Exchange (ETDEWEB)

    Steiner, J; Matthews, K; Jia, G [Louisiana State University, Baton Rouge, LA (United States)

    2016-06-15

    Purpose: To test feasibility of the use of a digital endorectal x-ray sensor for improved image resolution of permanent brachytherapy seed implants compared to conventional CT. Methods: Two phantoms simulating the male pelvic region were used to test the capabilities of a digital endorectal x-ray sensor for imaging permanent brachytherapy seed implants. Phantom 1 was constructed from acrylic plastic with cavities milled in the locations of the prostate and the rectum. The prostate cavity was filled a Styrofoam plug implanted with 10 training seeds. Phantom 2 was constructed from tissue-equivalent gelatins and contained a prostate phantom implanted with 18 strands of training seeds. For both phantoms, an intraoral digital dental x-ray sensor was placed in the rectum within 2 cm of the seed implants. Scout scans were taken of the phantoms over a limited arc angle using a CT scanner (80 kV, 120–200 mA). The dental sensor was removed from the phantoms and normal helical CT and scout (0 degree) scans using typical parameters for pelvic CT (120 kV, auto-mA) were collected. A shift-and add tomosynthesis algorithm was developed to localize seed plane location normal to detector face. Results: The endorectal sensor produced images with improved resolution compared to CT scans. Seed clusters and individual seed geometry were more discernable using the endorectal sensor. Seed 3D locations, including seeds that were not located in every projection image, were discernable using the shift and add algorithm. Conclusion: This work shows that digital endorectal x-ray sensors are a feasible method for improving imaging of permanent brachytherapy seed implants. Future work will consist of optimizing the tomosynthesis technique to produce higher resolution, lower dose images of 1) permanent brachytherapy seed implants for post-implant dosimetry and 2) fine anatomic details for imaging and managing prostatic disease compared to CT images. Funding: LSU Faculty Start-up Funding

  2. Evaluation of a new mid-scala cochlear implant electrode using microcomputed tomography.

    Science.gov (United States)

    Frisch, Christopher D; Carlson, Matthew L; Lane, John I; Driscoll, Colin L W

    2015-12-01

    To investigate electrode position, depth of insertion, and electrode contact using an electrode array with a mid-scala design following round window (RW) and cochleostomy insertion. Eight fresh-frozen cadaveric bones were implanted; half via a RW approach and half through an anteroinferior cochleostomy using a styleted mid-scala electrode design. Microcomputed tomography was used to acquire oblique coronal and oblique axial reformations. Individual electrode positions along each array, insertional depth, and electrode contact were determined using National Institutes of Health Image J software. All electrodes were inserted without significant resistance. The average angular depth of insertion was 436.5° for the RW group and 422.7° for the cochleostomy group. All electrodes acquired a perimodiolar position in the proximal segment and a lateral wall position at the basal turn, regardless of approach. Electrodes distal to the basal turn demonstrated a variable location, with 78% mid scala. One cochleostomy array fractured through the interscalar partition (ISP), acquiring a scala vestibuli position. The odds ratio for either abutting the modiolus, ISP, lateral wall or floor, or fracturing through the ISP were 2.7 times more likely following a cochleostomy insertion (P = .032). The styleted mid-scala electrode design acquires a proximal perimodiolar position, a lateral wall location, as it traverses the basal turn, and most commonly a mid-scala position in the distal array. Interscalar excursion occurred in one of the cochleostomy insertions. Cochleostomy insertion is more likely to result in ultimate final electrode position adjacent to critical intracochlear structures. NA. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  3. Scalar localization by cone-beam computed tomography of cochlear implant carriers: a comparative study between straight and periomodiolar precurved electrode arrays.

    Science.gov (United States)

    Boyer, Eric; Karkas, Alexandre; Attye, Arnaud; Lefournier, Virginie; Escude, Bernard; Schmerber, Sebastien

    2015-03-01

    To compare the incidence of dislocation of precurved versus straight flexible cochlear implant electrode arrays using cone-beam computed tomography (CBCT) image analyses. Consecutive nonrandomized case-comparison study. Tertiary referral center. Analyses of patients' CBCT images after cochlear implant surgery. Precurved and straight flexible electrode arrays from two different manufacturers were implanted. A round window insertion was performed in most cases. Two cases necessitated a cochleostomy. The patients' CBCT images were reconstructed in the coronal oblique, sagittal oblique, and axial oblique section. The insertion depth angle and the incidence of dislocation from the scala tympani to the scala vestibuli were determined. The CBCT images and the incidence of dislocation were analyzed in 54 patients (61 electrode arrays). Thirty-one patients were implanted with a precurved perimodiolar electrode array and 30 patients with a straight flexible electrode array. A total of nine (15%) scalar dislocations were observed in both groups. Eight (26%) scalar dislocations were observed in the precurved array group and one (3%) in the straight array group. Dislocation occurred at an insertion depth angle between 170 and 190 degrees in the precurved array group and at approximately 370 degrees in the straight array group. With precurved arrays, dislocation usually occurs in the ascending part of the basal turn of the cochlea. With straight flexible electrode arrays, the incidence of dislocation was lower, and it seems that straight flexible arrays have a higher chance of a confined position within the scala tympani than perimodiolar precurved arrays.

  4. Insertion forces and intracochlear trauma in temporal bone specimens implanted with a straight atraumatic electrode array.

    Science.gov (United States)

    Mirsalehi, Marjan; Rau, Thomas S; Harbach, Lenka; Hügl, Silke; Mohebbi, Saleh; Lenarz, Thomas; Majdani, Omid

    2017-05-01

    The aim of the study was to evaluate insertion forces during manual insertion of a straight atraumatic electrode in human temporal bones, and post-implantation histologic evaluation of the samples to determine whether violation of intracochlear structures is related to insertion forces. In order to minimize intracochlear trauma and preserve residual hearing during cochlear implantation, knowledge of the insertion forces is necessary. Ten fresh frozen human temporal bones were prepared with canal wall down mastoidectomy. All samples were mounted on a one-axis force sensor. Insertion of a 16-mm straight atraumatic electrode was performed from different angles to induce "traumatic" insertion. Histologic evaluation was performed in order to evaluate intracochlear trauma. In 4 of 10 samples, dislocation of the electrode into scala vestibuli was observed. The mean insertion force for all 10 procedures was 0.003 ± 0.005 N. Insertion forces measured around the site of dislocation to scala vestibuli in 3 of 4 samples were significantly higher than insertion forces at the same location of the cochleae measured in samples without trauma (p straight atraumatic electrode is lower than reported by other studies using longer electrodes. Based on our study, insertion forces leading to basilar membrane trauma may be lower than the previously reported direct rupture forces.

  5. Threshold and channel interaction in cochlear implant users: evaluation of the tripolar electrode configuration.

    Science.gov (United States)

    Bierer, Julie Arenberg

    2007-03-01

    The efficacy of cochlear implants is limited by spatial and temporal interactions among channels. This study explores the spatially restricted tripolar electrode configuration and compares it to bipolar and monopolar stimulation. Measures of threshold and channel interaction were obtained from nine subjects implanted with the Clarion HiFocus-I electrode array. Stimuli were biphasic pulses delivered at 1020 pulses/s. Threshold increased from monopolar to bipolar to tripolar stimulation and was most variable across channels with the tripolar configuration. Channel interaction, quantified by the shift in threshold between single- and two-channel stimulation, occurred for all three configurations but was largest for the monopolar and simultaneous conditions. The threshold shifts with simultaneous tripolar stimulation were slightly smaller than with bipolar and were not as strongly affected by the timing of the two channel stimulation as was monopolar. The subjects' performances on clinical speech tests were correlated with channel-to-channel variability in tripolar threshold, such that greater variability was related to poorer performance. The data suggest that tripolar channels with high thresholds may reveal cochlear regions of low neuron survival or poor electrode placement.

  6. Electrode spanning with partial tripolar stimulation mode in cochlear implants.

    Science.gov (United States)

    Wu, Ching-Chih; Luo, Xin

    2014-12-01

    The perceptual effects of electrode spanning (i.e., the use of nonadjacent return electrodes) in partial tripolar (pTP) mode were tested on a main electrode EL8 in five cochlear implant (CI) users. Current focusing was controlled by σ (the ratio of current returned within the cochlea), and current steering was controlled by α (the ratio of current returned to the basal electrode). Experiment 1 tested whether asymmetric spanning with α = 0.5 can create additional channels around standard pTP stimuli. It was found that in general, apical spanning (i.e., returning current to EL6 rather than EL7) elicited a pitch between those of standard pTP stimuli on main electrodes EL8 and EL9, while basal spanning (i.e., returning current to EL10 rather than EL9) elicited a pitch between those of standard pTP stimuli on main electrodes EL7 and EL8. The pitch increase caused by apical spanning was more salient than the pitch decrease caused by basal spanning. To replace the standard pTP channel on the main electrode EL8 when EL7 or EL9 is defective, experiment 2 tested asymmetrically spanned pTP stimuli with various α, and experiment 3 tested symmetrically spanned pTP stimuli with various σ. The results showed that pitch increased with decreasing α in asymmetric spanning, or with increasing σ in symmetric spanning. Apical spanning with α around 0.69 and basal spanning with α around 0.38 may both elicit a similar pitch as the standard pTP stimulus. With the same σ, the symmetrically spanned pTP stimulus was higher in pitch than the standard pTP stimulus. A smaller σ was thus required for symmetric spanning to match the pitch of the standard pTP stimulus. In summary, electrode spanning is an effective field-shaping technique that is useful for adding spectral channels and handling defective electrodes with CIs.

  7. Implantation port-catheter permanent indwelling of pulmonary artery in treating lung metastasis from HCC

    International Nuclear Information System (INIS)

    Cheng Jiemin; Wang Jianhua; Yan Zhiping; Wang Xiaolin; Gong Gaoquan; Liu Qingxin

    2000-01-01

    Objective: To observe the efficacy of a percutaneous implantation port-catheter permanent indwelling pulmonary artery for regional chemotherapy of the metastatic lung cancer from HCC. Methods: Between 1995 and 1999, 62 patients (42 males, 20 females; mean age 46 years) suffering from the metastatic lung cancer from HCC underwent percutaneous implantation of port-catheter permanent indwelling pulmonary artery using the right subclavian vein. In 19 patients with metastatic tumor located on one side of the lung, an indwelling catheter was placed into the ipsilateral side pulmonary artery. With metastasis of both sides, the catheter was inserted into the main trunk of pulmonary artery. The regimens of the chemotherapy were 5-FU + CDDP + MMC(FDM) or 5-FU + CDDP + MMC(FDA). Results: The interventional procedure was successfully completed in all 62 cases (100%). The complications occurred in 8% cases, including infections (3.2%), unhealed wound (1.6%) and pneumothorax (3.2%). The treatment effects of 3-months after the procedure were as follows: the obvious decrease of lung tumor size was 35.5%; stable disease (SD) 32.3% and progressive disease (PD) 32.3%. 6 months follow-up: 12 patients were dead (12/62) and the others are still doing well. The response rates were 22.6%, partial response (PR) 32.3%; stable disease (SD) 25.8% and progressive disease (PD) 32.3%. Conclusions: The percutaneous implantation techniques of pulmonary arterial port-catheter could be a good method in the treatment of metastatic lung cancer from HCC because of it is simple, with few complications and positive effect

  8. Negative-ion current density dependence of the surface potential of insulated electrode during negative-ion implantation

    International Nuclear Information System (INIS)

    Tsuji, Hiroshi; Okayama, Yoshio; Toyota, Yoshitaka; Gotoh, Yasuhito; Ishikawa, Junzo; Sakai, Shigeki; Tanjyo, Masayasu; Matsuda, Kouji.

    1994-01-01

    Positive ion implantation has been utilized as the method of impurity injection in ultra-LSI production, but the problem of substrate charging cannot be resolved by conventional charge compensation method. It was forecast that by negative ion implantation, this charging problem can be resolved. Recently the experiment on the negative ion implantation into insulated electrodes was carried out, and the effect of negative ion implantation to this problem was proved. However, the dependence of charged potential on the increase of negative ion current at the time of negative ion implantation is a serious problem in large current negative ion implantation hereafter. The charged potential of insulated conductor substrates was measured by the negative ion implantation using the current up to several mA/cm 2 . The experimental method is explained. Medium current density and high current density negative ion implantation and charged potential are reported. Accordingly in negative ion implantation, if current density is optimized, the negative ion implantation without charging can be realized. (K.I.)

  9. Electrode Impedance Fluctuations as a Biomarker for Inner Ear Pathology After Cochlear Implantation.

    Science.gov (United States)

    Choi, June; Payne, Matthew R; Campbell, Luke J; Bester, Christo W; Newbold, Carrie; Eastwood, Hayden; O'Leary, Stephen J

    2017-12-01

    Cochlear implant surgery now aims to preserve residual low frequency hearing. The current research explores whether fluctuations in the electrical impedance of cochlear implant electrodes may act as a biomarker for pathological changes that lead to the delayed loss of residual hearing. Secondary analysis of a double-blinded randomized trial, where methylprednisolone was administered intravenously before cochlear implantation with a view to preserving residual hearing. Seventy-four patients with residual hearing after cochlear implant surgery were investigated for an impedance "spike," defined as a median rise of ≥4 kΩ across all electrodes from the baseline measurements. Spikes were related to objective and subjective hearing loss, dizziness, and tinnitus. An impedance spike occurred in 14% (10/74) of enrolled patients. Three months after surgery, five patients exhibited spikes and three of these patients had a total loss of their residual hearing. 4.3% of the 69 patients without spikes lost residual hearing. At 1 year, 9 of 10 patients who exhibited spikes had lost all their residual hearing. 8.1% of the 37 patients who did not experience a spike lost their residual hearing. Seventy percent of patients exhibiting a spike also experienced vertigo. The administration of steroids at the time of surgery did not influence the occurrence of spikes. Our results suggest that there is a relationship between a spike and the loss of residual hearing. It seems that rises in impedance can reflect pathology within the inner ear and predict the future loss of residual hearing.

  10. An Implantable Wireless Neural Interface System for Simultaneous Recording and Stimulation of Peripheral Nerve with a Single Cuff Electrode.

    Science.gov (United States)

    Shon, Ahnsei; Chu, Jun-Uk; Jung, Jiuk; Kim, Hyungmin; Youn, Inchan

    2017-12-21

    Recently, implantable devices have become widely used in neural prostheses because they eliminate endemic drawbacks of conventional percutaneous neural interface systems. However, there are still several issues to be considered: low-efficiency wireless power transmission; wireless data communication over restricted operating distance with high power consumption; and limited functionality, working either as a neural signal recorder or as a stimulator. To overcome these issues, we suggest a novel implantable wireless neural interface system for simultaneous neural signal recording and stimulation using a single cuff electrode. By using widely available commercial off-the-shelf (COTS) components, an easily reconfigurable implantable wireless neural interface system was implemented into one compact module. The implantable device includes a wireless power consortium (WPC)-compliant power transmission circuit, a medical implant communication service (MICS)-band-based radio link and a cuff-electrode path controller for simultaneous neural signal recording and stimulation. During in vivo experiments with rabbit models, the implantable device successfully recorded and stimulated the tibial and peroneal nerves while communicating with the external device. The proposed system can be modified for various implantable medical devices, especially such as closed-loop control based implantable neural prostheses requiring neural signal recording and stimulation at the same time.

  11. An Implantable Wireless Neural Interface System for Simultaneous Recording and Stimulation of Peripheral Nerve with a Single Cuff Electrode

    Directory of Open Access Journals (Sweden)

    Ahnsei Shon

    2017-12-01

    Full Text Available Recently, implantable devices have become widely used in neural prostheses because they eliminate endemic drawbacks of conventional percutaneous neural interface systems. However, there are still several issues to be considered: low-efficiency wireless power transmission; wireless data communication over restricted operating distance with high power consumption; and limited functionality, working either as a neural signal recorder or as a stimulator. To overcome these issues, we suggest a novel implantable wireless neural interface system for simultaneous neural signal recording and stimulation using a single cuff electrode. By using widely available commercial off-the-shelf (COTS components, an easily reconfigurable implantable wireless neural interface system was implemented into one compact module. The implantable device includes a wireless power consortium (WPC-compliant power transmission circuit, a medical implant communication service (MICS-band-based radio link and a cuff-electrode path controller for simultaneous neural signal recording and stimulation. During in vivo experiments with rabbit models, the implantable device successfully recorded and stimulated the tibial and peroneal nerves while communicating with the external device. The proposed system can be modified for various implantable medical devices, especially such as closed-loop control based implantable neural prostheses requiring neural signal recording and stimulation at the same time.

  12. Conduction Abnormalities and Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement Using the Repositionable LOTUS Device: The United Kingdom Experience.

    Science.gov (United States)

    Rampat, Rajiv; Khawaja, M Zeeshan; Hilling-Smith, Roland; Byrne, Jonathan; MacCarthy, Philip; Blackman, Daniel J; Krishnamurthy, Arvindra; Gunarathne, Ashan; Kovac, Jan; Banning, Adrian; Kharbanda, Raj; Firoozi, Sami; Brecker, Stephen; Redwood, Simon; Bapat, Vinayak; Mullen, Michael; Aggarwal, Suneil; Manoharan, Ganesh; Spence, Mark S; Khogali, Saib; Dooley, Maureen; Cockburn, James; de Belder, Adam; Trivedi, Uday; Hildick-Smith, David

    2017-06-26

    The authors report the incidence of pacemaker implantation up to hospital discharge and the factors influencing pacing rate following implantation of the LOTUS bioprosthesis (Boston Scientific, Natick, Massachusetts) in the United Kingdom. Transcatheter aortic valve replacement (TAVR) is associated with a significant need for permanent pacemaker implantation. Pacing rates vary according to the device used. The REPRISE II (Repositionable Percutaneous Replacement of Stenotic Aortic Valve Through Implantation of Lotus Valve System) trial reported a pacing rate of 29% at 30 days after implantation of the LOTUS device. Data were collected retrospectively on 228 patients who had the LOTUS device implanted between March 2013 and February 2015 across 10 centers in the United Kingdom. Twenty-seven patients (12%) had pacemakers implanted pre-procedure and were excluded from the analysis. Patients were aged 81.2 ± 7.7 years; 50.7% were male. The mean pre-procedural QRS duration was 101.7 ± 20.4 ms. More than one-half of the cohort (n = 111, 55%) developed new left bundle branch block (LBBB) following the procedure. Permanent pacemakers were implanted in 64 patients (32%) with a median time to insertion of 3.0 ± 3.4 days. Chief indications for pacing were atrioventricular (AV) block (n = 46, 72%), or LBBB with 1st degree AV block (n = 11, 17%). Amongst those who received a pacemaker following TAVR the pre-procedural electrocardiogram findings included: No conduction disturbance (n = 41, 64%); 1st degree AV block (n = 10, 16%); right bundle branch block (n = 6, 9%) and LBBB (n = 5, 8%). LBBB (but not permanent pacemaker) occurred more frequently in patients who had balloon aortic valvuloplasty before TAVR (odds ratio [OR]: 1.25; p = 0.03). Pre-procedural conduction abnormality (composite of 1st degree AV block, hemiblock, right bundle branch block, LBBB) was independently associated with the need for permanent pacemaker (OR: 2.54; p = 0.048). The absence of

  13. Monitoring the evolution of boron doped porous diamond electrode on flexible retinal implant by OCT and in vivo impedance spectroscopy

    International Nuclear Information System (INIS)

    Hébert, Clément; Cottance, Myline; Degardin, Julie; Scorsone, Emmanuel; Rousseau, Lionel; Lissorgues, Gaelle; Bergonzo, Philippe; Picaud, Serge

    2016-01-01

    Nanocrystalline Boron doped Diamond proved to be a very attractive material for neural interfacing, especially with the retina, where reduce glia growth is observed with respect to other materials, thus facilitating neuro-stimulation over long terms. In the present study, we integrated diamond microelectrodes on a polyimide substrate and investigated their performances for the development of neural prosthesis. A full description of the microfabrication of the implants is provided and their functionalities are assessed using cyclic voltammetry and electrochemical impedance spectroscopy. A porous structure of the electrode surface was thus revealed and showed promising properties for neural recording or stimulation. Using the flexible implant, we showed that is possible to follow in vivo the evolution of the electric contact between the diamond electrodes and the retina over 4 months by using electrochemical impedance spectroscopy. The position of the implant was also monitored by optical coherence tomography to corroborate the information given by the impedance measurements. The results suggest that diamond microelectrodes are very good candidates for retinal prosthesis. - Highlights: • Microfabrication of porous diamond electrode on flexible retinal implant • Electrochemical characterization of microelectrode for neural interfacing • In vivo impedance spectroscopy of retinal tissue

  14. Monitoring the evolution of boron doped porous diamond electrode on flexible retinal implant by OCT and in vivo impedance spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Hébert, Clément, E-mail: clement.hebert@icn2.cat [CEA-LIST, Diamond Sensors Laboratory, Gif-sur-Yvette 91191 (France); Cottance, Myline [Université Paris-Est, ESYCOM-ESIEE Paris, Noisy le Grand (France); Degardin, Julie [INSERM, U968, Institut de la Vision, Paris (France); Scorsone, Emmanuel [CEA-LIST, Diamond Sensors Laboratory, Gif-sur-Yvette 91191 (France); Rousseau, Lionel; Lissorgues, Gaelle [Université Paris-Est, ESYCOM-ESIEE Paris, Noisy le Grand (France); Bergonzo, Philippe [CEA-LIST, Diamond Sensors Laboratory, Gif-sur-Yvette 91191 (France); Picaud, Serge [INSERM, U968, Institut de la Vision, Paris (France)

    2016-12-01

    Nanocrystalline Boron doped Diamond proved to be a very attractive material for neural interfacing, especially with the retina, where reduce glia growth is observed with respect to other materials, thus facilitating neuro-stimulation over long terms. In the present study, we integrated diamond microelectrodes on a polyimide substrate and investigated their performances for the development of neural prosthesis. A full description of the microfabrication of the implants is provided and their functionalities are assessed using cyclic voltammetry and electrochemical impedance spectroscopy. A porous structure of the electrode surface was thus revealed and showed promising properties for neural recording or stimulation. Using the flexible implant, we showed that is possible to follow in vivo the evolution of the electric contact between the diamond electrodes and the retina over 4 months by using electrochemical impedance spectroscopy. The position of the implant was also monitored by optical coherence tomography to corroborate the information given by the impedance measurements. The results suggest that diamond microelectrodes are very good candidates for retinal prosthesis. - Highlights: • Microfabrication of porous diamond electrode on flexible retinal implant • Electrochemical characterization of microelectrode for neural interfacing • In vivo impedance spectroscopy of retinal tissue.

  15. Localizing ECoG electrodes on the cortical anatomy without post-implantation imaging

    Science.gov (United States)

    Gupta, Disha; Hill, N. Jeremy; Adamo, Matthew A.; Ritaccio, Anthony; Schalk, Gerwin

    2014-01-01

    Introduction Electrocorticographic (ECoG) grids are placed subdurally on the cortex in people undergoing cortical resection to delineate eloquent cortex. ECoG signals have high spatial and temporal resolution and thus can be valuable for neuroscientific research. The value of these data is highest when they can be related to the cortical anatomy. Existing methods that establish this relationship rely either on post-implantation imaging using computed tomography (CT), magnetic resonance imaging (MRI) or X-Rays, or on intra-operative photographs. For research purposes, it is desirable to localize ECoG electrodes on the brain anatomy even when post-operative imaging is not available or when intra-operative photographs do not readily identify anatomical landmarks. Methods We developed a method to co-register ECoG electrodes to the underlying cortical anatomy using only a pre-operative MRI, a clinical neuronavigation device (such as BrainLab VectorVision), and fiducial markers. To validate our technique, we compared our results to data collected from six subjects who also had post-grid implantation imaging available. We compared the electrode coordinates obtained by our fiducial-based method to those obtained using existing methods, which are based on co-registering pre- and post-grid implantation images. Results Our fiducial-based method agreed with the MRI–CT method to within an average of 8.24 mm (mean, median = 7.10 mm) across 6 subjects in 3 dimensions. It showed an average discrepancy of 2.7 mm when compared to the results of the intra-operative photograph method in a 2D coordinate system. As this method does not require post-operative imaging such as CTs, our technique should prove useful for research in intra-operative single-stage surgery scenarios. To demonstrate the use of our method, we applied our method during real-time mapping of eloquent cortex during a single-stage surgery. The results demonstrated that our method can be applied intra

  16. Identifying cochlear implant channels with poor electrode-neuron interface: partial tripolar, single-channel thresholds and psychophysical tuning curves.

    Science.gov (United States)

    Bierer, Julie Arenberg; Faulkner, Kathleen F

    2010-04-01

    The goal of this study was to evaluate the ability of a threshold measure, made with a restricted electrode configuration, to identify channels exhibiting relatively poor spatial selectivity. With a restricted electrode configuration, channel-to-channel variability in threshold may reflect variations in the interface between the electrodes and auditory neurons (i.e., nerve survival, electrode placement, and tissue impedance). These variations in the electrode-neuron interface should also be reflected in psychophysical tuning curve (PTC) measurements. Specifically, it is hypothesized that high single-channel thresholds obtained with the spatially focused partial tripolar (pTP) electrode configuration are predictive of wide or tip-shifted PTCs. Data were collected from five cochlear implant listeners implanted with the HiRes90k cochlear implant (Advanced Bionics Corp., Sylmar, CA). Single-channel thresholds and most comfortable listening levels were obtained for stimuli that varied in presumed electrical field size by using the pTP configuration for which a fraction of current (sigma) from a center-active electrode returns through two neighboring electrodes and the remainder through a distant indifferent electrode. Forward-masked PTCs were obtained for channels with the highest, lowest, and median tripolar (sigma = 1 or 0.9) thresholds. The probe channel and level were fixed and presented with either the monopolar (sigma = 0) or a more focused pTP (sigma > or = 0.55) configuration. The masker channel and level were varied, whereas the configuration was fixed to sigma = 0.5. A standard, three-interval, two-alternative forced choice procedure was used for thresholds and masked levels. Single-channel threshold and variability in threshold across channels systematically increased as the compensating current, sigma, increased and the presumed electrical field became more focused. Across subjects, channels with the highest single-channel thresholds, when measured with a

  17. Bypassing the learning curve in permanent seed implants using state-of-the-art technology

    International Nuclear Information System (INIS)

    Beaulieu, Luc; Evans, Dee-Ann Radford; Aubin, Sylviane; Angyalfi, Steven; Husain, Siraj; Kay, Ian; Martin, Andre-Guy; Varfalvy, Nicolas; Vigneault, Eric; Dunscombe, Peter

    2007-01-01

    Purpose: The aim of this study was to demonstrate, based on clinical postplan dose distributions, that technology can be used efficiently to eliminate the learning curve associated with permanent seed implant planning and delivery. Methods and Materials: Dose distributions evaluated 30 days after the implant of the initial 22 consecutive patients treated with permanent seed implants at two institutions were studied. Institution 1 (I1) consisted of a new team, whereas institution 2 (I2) had performed more than 740 preplanned implantations over a 9-year period before the study. Both teams had adopted similar integrated systems based on three-dimensional (3D) transrectal ultrasonography, intraoperative dosimetry, and an automated seed delivery and needle retraction system (FIRST, Nucletron). Procedure time and dose volume histogram parameters such as D90, V100, V150, V200, and others were collected in the operating room and at 30 days postplan. Results: The average target coverage from the intraoperative plan (V100) was 99.4% for I1 and 99.9% for I2. D90, V150, and V200 were 191.4 Gy (196.3 Gy), 75.3% (73.0%), and 37.5% (34.1%) for I1 (I2) respectively. None of these parameters shows a significant difference between institutions. The postplan D90 was 151.2 Gy for I1 and 167.3 Gy for I2, well above the 140 Gy from the Stock et al. analysis, taking into account differences at planning, results in a p value of 0.0676. The procedure time required on average 174.4 min for I1 and 89 min for I2. The time was found to decrease with the increasing number of patients. Conclusion: State-of-the-art technology enables a new brachytherapy team to obtain excellent postplan dose distributions, similar to those achieved by an experienced team with proven long-term clinical results. The cost for bypassing the usual dosimetry learning curve is time, with increasing team experience resulting in shorter treatment times

  18. FY 1998 annual report on the development of novel, high-activity oxygen electrode by ion-implantation; 1998 nendo ion chunyuho ni yoru shinkina kokassei sanso denkyoku no kaihatsu chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    An attempt has been made to develop an electrode material having high activity for oxygen generating reactions by ion-implantation, which is used to form the bulk defects (fine gaps at the atomic level) on the electrode surface, considered to serve as the active sites. It is found that implantation of the Co{sup +} or Zn{sup +} ion into a compound oxide electrode of Ti and Ru is accompanied by decreased overvoltage for oxygen generation by 50 to 100 mV. The Co{sup +} and Zn{sup +} ions, when implanted, cause damage of similar density in the thin film, decreasing its overvoltage to a similar extent, in spite of their different chemical properties, from which it is considered that the effect of ion implantation is not to change chemical properties of the film but to form a structural defect therein. A thin-film electrode of ruthenium dioxide, which is considered to be the oxygen generating electrode of the highest activity at present, is prepared and implanted with the Ru{sup +} ion, to observe the effect. The ion implantation also decreases the overvoltage by 50 to 70 mV, demonstrating its effect. The same principle is expected to be applicable to development of high-activity oxygen reducing electrode (electrode for fuel cell). (NEDO)

  19. SU-F-T-653: Radiation Exposure from Cs-131 Permanent Seed Implants

    Energy Technology Data Exchange (ETDEWEB)

    Giaddui, T; Hardin, M; To, D; Kremmel, E; Peng, C; Hann, P; Richardson, S; Yu, Y; Harrison, A; Doyle, L [Sidney Kimmel Cancer Center, Thomas Jefferson University, Philadelphia, PA (United States)

    2016-06-15

    Purpose: Permanent seed implants have traditionally been used to treat prostate, lung and head or neck cancers using I-125 and Pd-103. Cs-131, which has higher dose rate is being used to treat brain, head and/or neck cancers in our clinic, therefore, we chose to monitor the dose received by surgeons during the extensive procedure. The aims of this work are to assess the level of radiation exposure to surgeons and the instantaneous exposure at bedside and 1 m from patients. Methods: Ten patients received Cs-131 implants for recurrent brain,head and/or neck cancer; the median implanted activity, number of implanted seeds and prescription dose at 0.5 cm from the perpendicular plane of the implant were: 54.3 mCi (14.52 – 77); 19 (4 – 24) and 60 Gy (range 42 – 60) respectively. Radiation exposure was recorded at bedside and 1 m from the patient using Victoreen ion chamber (Fluke Biomedical, Cleveland, OH). Exposure to surgeons was measured using TLD (Mirion Technologies (GDS), Inc., USA). Results: The median equivalent dose rate at 1 m and bedside immediately following implantation were 1.49×10-2 mSv/h (8.77×10-3–2.63×10-2) and 7.76×10-2 mSv/h (3.1×10-2– 1.53×10-1) respectively. Median equivalent dose to surgeons’ hands was 0.60 mSv (0.33 – 1.48) and no doses were detected for whole-body. Surgical reconstruction for one patient was performed 71 days post-implant and resulted in zero exposure to surgeons. Conclusion: The recorded exposure rates were low when compared with the literature. Post procedure surveys at bed site and 1 m indicated that all patients were within safe limits for discharge (< 0.05 mSv/h at 1 m). However, as a precautionary measure, patients were advised to avoid direct contact with children and pregnant women within four weeks of the implant and stay at least at 3 ft from other people. Surgeons doses were well within occupational dose limits.

  20. Treatment of prostate adenocarcinoma permanent implants with I 125: first experience in Uruguay

    International Nuclear Information System (INIS)

    Quarneti, A.; Clark, O.; Glaussius, A.; Kaitasoff, P.; Cosia, G.

    2010-01-01

    Full text: Objective: To report on the treatment done, toxicity and development of a group of adenocarcinoma patients with localized prostate brachytherapy implants permanent I125. Material and Methods. 37 patients were treated in the period 2001 to 2004 at the Military Hospital Central by this treatment modality. All of them were performed before implantation planning, which consisted of the volumetric calculation and calculation prostate dosimetry that included transrectal prostate ultrasound 3-5 weeks before the procedure. all patients had pathological confirmation of the lesion showed PSA values less than 11 ng / ml and Gleason score less than 7. 70% of patients received neo-adjuvant hormone therapy. In 5 patients an interactive planning system was performed computerized dosimetry, using sequential ultrasound imaging planes, allowed the dosimetric analysis before terminate the procedure and make necessary adjustments if the dose distribution did not conform. This additional dosimetric study we have not been described by other authors. Prescribed in the first 10 patients was dose 144 Gy and 160 Gy in subsequent. All patients underwent post implant CT waffle grid after 15 days of the procedure. analyzed the dose volume histogram (HDV) and D90 values??. Clinical follow-up was performed and PSA biochemical .. Preliminary Results: 33 patients were in local control without biochemical failure. Currently 4 patients presented biochemical recurrence with PSA values ??between 4 and 6 ng / ml. In neither disease was found at a distance and then raises confirmation tumor biopsy active presence will undergo surgical treatment protocols localized prostate cancer. HDV values ??D90 and are consistent with the informed by the international literature will be presented. No patient required hospitalization prolonged (greater than 24 hours) or use of higher analgesics. 2 patients had acute urinary retention (G II complication) between the tenth and twentieth day, the rest of the

  1. Radiation protection procedures and dose to the staff in brachytherapy with permanent implant of the sources

    International Nuclear Information System (INIS)

    Tosi, G.; Cattani, F.

    2002-01-01

    The treatment of intra capsular prostate cancers with the permanent implantation of low energy sealed radioactive sources (''103 Pd-''125I) offers the same probability of curing the tumours as surgery and external-beam radiotherapy with a minimum incidence of unwanted side-effects. The first attempts of using sealed sources for treating prostate cancers go back to 1917, when Barringer reported the results obtained with the implant of ''236Ra needles. Beginning from that period the interest for prostate brachytherapy has shown a fluctuating trend, due especially to the technological possibilities and to the status of the alternative treatment modalities (surgery, external radiotherapy). The main reason of the substantial failure of brachytherapy as compared to the two other treatment modalities had two main causes: the energy, too high ( E≅ 840 keV), of γ-radiation emitted by ''226 Ra in equilibrium with its decay products and the lack of imaging techniques able to visualize with sufficient accuracy both the prostate and the arrangement, inside it, of the radioactive sources. The employ of low energy γ-emitting radionuclides began in 1974, when Whitmore et al. working at the Sloan Kettering Memorial Cancer Hospital of New York suggested the use of ''125 I sealed sources for the realisation of interstitial permanent implants. Also this attempt, though reducing the side effects typical of the surgical intervention (incontinence, impotence), did non give the expected results in terms of local control of the disease and, as a consequence, of the survival's length. This partial failure was attributed to the fact that, in most cases the dose distribution inside the target volume was not homogeneous, due to the inadequacy of the available imaging techniques used for checking the real position of the sources, during their manual insertion in the tissues. In the last ten years,however, great progresses have been made in the US i maging techniques, in the manufacture of

  2. Exclusive curietherapy by permanent iodine-125 implants: selection of patients and results after eight years; Curietherapie exclusive par implants permanents d'iode-125: selection des patients et resultats a huit ans

    Energy Technology Data Exchange (ETDEWEB)

    Boutenbat, G.; Peiffert, D.; Bernier, V.; Moreau, J.L.; Boudran, G.; Noel, A.; Marchesi, V.; Huget, S. [Centre Alexis Vautrin, 54 - Vandoeuvre-Les-Nancy (France); Moreau, J.L. [Cabinet prive d' urologie, 54 - Nancy (France); Boudran, G. [Centre Hospitalier Universitaire de Brabois, 54 - Vandoeuvre-Les-Nancy (France)

    2010-10-15

    The authors report a retrospective study which assesses the results obtained over eight years and the toxicity of an exclusive curietherapy by permanent iodine-125 implants performed at the Nancy centre of struggle against cancer. More than five hundred patients have been treated between December 1999 and December 2007, a first group comprising patients suffering from a low risk cancer and a second group suffering from a medium risk cancer. The authors discuss the survival rates, the existence of side effects, and rectal toxicity results. Short communication

  3. Electrical Neural Stimulation and Simultaneous in Vivo Monitoring with Transparent Graphene Electrode Arrays Implanted in GCaMP6f Mice.

    Science.gov (United States)

    Park, Dong-Wook; Ness, Jared P; Brodnick, Sarah K; Esquibel, Corinne; Novello, Joseph; Atry, Farid; Baek, Dong-Hyun; Kim, Hyungsoo; Bong, Jihye; Swanson, Kyle I; Suminski, Aaron J; Otto, Kevin J; Pashaie, Ramin; Williams, Justin C; Ma, Zhenqiang

    2018-01-23

    Electrical stimulation using implantable electrodes is widely used to treat various neuronal disorders such as Parkinson's disease and epilepsy and is a widely used research tool in neuroscience studies. However, to date, devices that help better understand the mechanisms of electrical stimulation in neural tissues have been limited to opaque neural electrodes. Imaging spatiotemporal neural responses to electrical stimulation with minimal artifact could allow for various studies that are impossible with existing opaque electrodes. Here, we demonstrate electrical brain stimulation and simultaneous optical monitoring of the underlying neural tissues using carbon-based, fully transparent graphene electrodes implanted in GCaMP6f mice. Fluorescence imaging of neural activity for varying electrical stimulation parameters was conducted with minimal image artifact through transparent graphene electrodes. In addition, full-field imaging of electrical stimulation verified more efficient neural activation with cathode leading stimulation compared to anode leading stimulation. We have characterized the charge density limitation of capacitive four-layer graphene electrodes as 116.07-174.10 μC/cm 2 based on electrochemical impedance spectroscopy, cyclic voltammetry, failure bench testing, and in vivo testing. This study demonstrates the transparent ability of graphene neural electrodes and provides a method to further increase understanding and potentially improve therapeutic electrical stimulation in the central and peripheral nervous systems.

  4. Optimal needle arrangement for intraoperative planning in permanent I-125 prostate implants

    International Nuclear Information System (INIS)

    Thompson, S.A.; Fung, A.Y.C.; Zaider, M.

    2002-01-01

    One limitation of intraoperative planning of permanent prostate implants is that needles must already be in the gland before planning images are acquired. Improperly placed needles often restrict the capability of generating optimal seed placement. We developed guiding principles for the proper layout of needles within the treatment volume. The Memorial Sloan-Kettering Cancer Center planning system employs a genetic algorithm to find the optimal seed implantation pattern consistent with pre-assigned constraints (needle geometry, uniformity, conformity and the avoidance of high doses to urethra and rectum). Ultrasound volumes for twelve patients with I-125 implants were used to generate six plans per patient (total 72 plans) with different needle arrangements. The plans were evaluated in terms of V100 (percentage prostate volume receiving at least the prescription dose), U135 (percentage urethra volume receiving at least 135% of prescription dose), and CI (conformity index, the ratio of treatment volume to prescription dose volume.) The method termed POSTCTR, in which needles were placed on the periphery of the largest ultrasound slice and posterior central needles were placed as needed, consistently gave superior results for all prostate sizes. Another arrangement, labelled POSTLAT, where the needles were placed peripherally with additional needles in the posterior lateral lobes, also gave satisfactory results. We advocate two needle arrangements, POSTCTR and POSTLAT, with the former giving better results. (author)

  5. Optimal needle arrangement for intraoperative planning in permanent I-125 prostate implants

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, S.A. [Department of Medical Physics, North Shore-Long Island Jewish Health System, Manhassett, NY (United States); Fung, A.Y.C.; Zaider, M. [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    2002-08-21

    One limitation of intraoperative planning of permanent prostate implants is that needles must already be in the gland before planning images are acquired. Improperly placed needles often restrict the capability of generating optimal seed placement. We developed guiding principles for the proper layout of needles within the treatment volume. The Memorial Sloan-Kettering Cancer Center planning system employs a genetic algorithm to find the optimal seed implantation pattern consistent with pre-assigned constraints (needle geometry, uniformity, conformity and the avoidance of high doses to urethra and rectum). Ultrasound volumes for twelve patients with I-125 implants were used to generate six plans per patient (total 72 plans) with different needle arrangements. The plans were evaluated in terms of V100 (percentage prostate volume receiving at least the prescription dose), U135 (percentage urethra volume receiving at least 135% of prescription dose), and CI (conformity index, the ratio of treatment volume to prescription dose volume.) The method termed POSTCTR, in which needles were placed on the periphery of the largest ultrasound slice and posterior central needles were placed as needed, consistently gave superior results for all prostate sizes. Another arrangement, labelled POSTLAT, where the needles were placed peripherally with additional needles in the posterior lateral lobes, also gave satisfactory results. We advocate two needle arrangements, POSTCTR and POSTLAT, with the former giving better results. (author)

  6. Preliminary fluid channel design and thermal-hydraulic analysis of glow discharge cleaning permanent electrode

    Energy Technology Data Exchange (ETDEWEB)

    Cai, Lijun, E-mail: cailj@swip.ac.cn [Southwestern Institute of Physics, Chengdu (China); Lin, Tao; Wang, Yingqiao; Wang, Mingxu [Southwestern Institute of Physics, Chengdu (China); Maruyama, So; Yang, Yu; Kiss, Gabor [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France)

    2016-11-01

    Highlights: • The plasma facing closure cap has to survive after 30,000 thermal heat load cycles. • 0.35 MW/m2 radiation heat load plus nuclear heat load are very challenging for stainless steel. • Multilayer structure has been designed by using advanced welding and drilling technology to solve the neutron heating problem. • Accurate volumetric load application in analysis model by CFX has been mastered. - Abstract: Glow discharge cleaning (GDC) shall be used on ITER device to reduce and control impurity and hydrogenic fuel out-gassing from in-vessel plasma facing components. After first plasma, permanent electrode (PE) will be used to replace Temporary Electrode (TE) for subsequent operation. Two fundamental scenarios i.e., GDC and Plasma Operation State (POS) should be considered for electrode design, which requires the heat load caused by plasma radiation and neutron heating must be taken away by cooling water flowing inside the electrode. In this paper, multilayer cooling channels inside PE are preliminarily designed, and snakelike route in each layer is adopted to improve the heat exchange. Detailed thermal-hydraulic analyses have been done to validate the design feasibility or rationality. The analysis results show that during GDC the cooling water inlet and outlet temperature difference is far less than the allowable temperature rise under water flow rate 0.15 kg/s compromised by many factors. For POS, the temperature rise and pressure drop are within the design goals, but high thermal stress occurs on the front surface of closure cap of electrode. After several iterations of optimization of the closure cap, the equivalent strain range after 30,000 loading cycles for POS is well below 0.3% design goals.

  7. Pitch ranking, electrode discrimination, and physiological spread of excitation using current steering in cochlear implants

    Science.gov (United States)

    Goehring, Jenny L.; Neff, Donna L.; Baudhuin, Jacquelyn L.; Hughes, Michelle L.

    2014-01-01

    The first objective of this study was to determine whether adaptive pitch-ranking and electrode-discrimination tasks with cochlear-implant (CI) recipients produce similar results for perceiving intermediate “virtual-channel” pitch percepts using current steering. Previous studies have not examined both behavioral tasks in the same subjects with current steering. A second objective was to determine whether a physiological metric of spatial separation using the electrically evoked compound action potential spread-of-excitation (ECAP SOE) function could predict performance in the behavioral tasks. The metric was the separation index (Σ), defined as the difference in normalized amplitudes between two adjacent ECAP SOE functions, summed across all masker electrodes. Eleven CII or 90 K Advanced Bionics (Valencia, CA) recipients were tested using pairs of electrodes from the basal, middle, and apical portions of the electrode array. The behavioral results, expressed as d′, showed no significant differences across tasks. There was also no significant effect of electrode region for either task. ECAP Σ was not significantly correlated with pitch ranking or electrode discrimination for any of the electrode regions. Therefore, the ECAP separation index is not sensitive enough to predict perceptual resolution of virtual channels. PMID:25480063

  8. Orgasm after prostate curietherapy with iodine 125 permanent implants for localized cancer of the prostate

    International Nuclear Information System (INIS)

    Delaunay, B.; Plante, P.; Huyghe, E.; Delannes, M.; Bachaud, J.-M.; Salloum, A.; Thoulouzan, M.; Soulie, M.; Delavierre, D.; Wagner, F.; Jonca, F.

    2011-01-01

    Orgasm is a domain of male sexuality that remains underreported in literature. Our aim was to realize the first detailed analysis of orgasm in patients treated by 125 I permanent prostate brachytherapy for localized prostate cancer. In a series of 270 sexually active men treated by prostate brachytherapy ( 125 I permanent implantation), 241 (89%), mean age of 65 (43 80), participated in a mailed survey about sexual function after a mean time of 36 months (9 70). Erectile and ejaculatory functions and orgasm were explored using a mailed questionnaire. Two questions focused on orgasm. The first was about quality of orgasm (fast/intense/late, difficult/weak/absent) and the second about the presence of painful orgasm and its frequency (always/sometimes/often). After prostate brachytherapy, 81.3% of sexually active men conserved ejaculation and 90% orgasm. There was a significant deterioration of the quality of orgasm (P ≡ 0.0001). More than 50% of the patients had an altered orgasm (weak, difficult, absent) after brachytherapy, vs 16% before implantation (P ≡ 0.001). Men with a diminished ejaculation volume often had a weak/difficult orgasm (P ≡ 0.007). Neoadjuvant hormonal therapy did not seem to impact the quality of orgasm or the frequency of painful ejaculation. Patients who had an IIEF-5 score higher than 12 had frequently intense orgasm (26.7% vs 2.7%; P < 0.001) after brachytherapy. Sixty patients (30.3%) experienced often/sometimes painful ejaculation 12.9% (n ≡ 31) before implantation (P ≡ 0.0001). Most of the patients treated by prostate brachytherapy conserved orgasm after treatment. However, most of the patients described a deterioration of the quality of orgasm. (authors)

  9. CT-guided iodine-125 seed permanent implantation for recurrent head and neck cancers

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Yu L; Meng, Na; Wang, Jun J; Jiang, Ping [Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191 (China); Yuan, Hui SH; Liu, Chen [Department of Radiology, Peking University Third Hospital, Beijing, 100191 (China); Qu, Ang; Yang, Rui J [Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191 (China)

    2010-07-30

    To investigate the feasibility, and safety of {sup 125}I seed permanent implantation for recurrent head and neck carcinoma under CT-guidance. A retrospective study on 14 patients with recurrent head and neck cancers undergone {sup 125}I seed implantation with different seed activities. The post-plan showed that the actuarial D90 of {sup 125}I seeds ranged from 90 to 218 Gy (median, 157.5 Gy). The follow-up was 3 to 60 months (median, 13 months). The median local control was 18 months (95% CI, 6.1-29.9 months), and the 1-, 2-, 3-, and 5- year local controls were 52%, 39%, 39%, and 39%, respectively. The 1-, 2-, 3-, and 5- survival rates were 65%, 39%, 39% and 39%, respectively, with a median survival time of 20 months (95% CI, 8.7-31.3 months). Of all patients, 28.6% (4/14) died of local recurrence, 7.1% (1/14) died of metastases, one patient died of hepatocirrhosis, and 8 patients are still alive to the date of data analysis. CT-guided {sup 125}I seed implantation is feasible and safe as a salvage or palliative treatment for patients with recurrent head and neck cancers.

  10. The Summating Potential Is a Reliable Marker of Electrode Position in Electrocochleography: Cochlear Implant as a Theragnostic Probe.

    Science.gov (United States)

    Helmstaedter, Victor; Lenarz, Thomas; Erfurt, Peter; Kral, Andrej; Baumhoff, Peter

    2017-12-14

    For the increasing number of cochlear implantations in subjects with residual hearing, hearing preservation, and thus the prevention of implantation trauma, is crucial. A method for monitoring the intracochlear position of a cochlear implant (CI) and early indication of imminent cochlear trauma would help to assist the surgeon to achieve this goal. The aim of this study was to evaluate the reliability of the different electric components recorded by an intracochlear electrocochleography (ECochG) as markers for the cochleotopic position of a CI. The measurements were made directly from the CI, combining intrasurgical diagnostics with the therapeutical use of the CI, thus, turning the CI into a "theragnostic probe." Intracochlear ECochGs were measured in 10 Dunkin Hartley guinea pigs of either sex, with normal auditory brainstem response thresholds. All subjects were fully implanted (4 to 5 mm) with a custom six contact CI. The ECochG was recorded simultaneously from all six contacts with monopolar configuration (retroauricular reference electrode). The gross ECochG signal was filtered off-line to separate three of its main components: compound action potential, cochlear microphonic, and summating potential (SP). Additionally, five cochleae were harvested and histologically processed to access the spatial position of the CI contacts. Both ECochG data and histological reconstructions of the electrode position were fitted with the Greenwood function to verify the reliability of the deduced cochleotopic position of the CI. SPs could be used as suitable markers for the frequency position of the recording electrode with an accuracy of ±1/4 octave in the functioning cochlea, verified by histology. Cochlear microphonics showed a dependency on electrode position but were less reliable as positional markers. Compound action potentials were not suitable for CI position information but were sensitive to "cochlear health" (e.g., insertion trauma). SPs directly recorded from

  11. Identifying cochlear implant channels with poor electrode-neuron interface: electrically-evoked auditory brainstem responses measured with the partial tripolar configuration

    Science.gov (United States)

    Bierer, Julie Arenberg; Faulkner, Kathleen F.; Tremblay, Kelly L.

    2011-01-01

    Objectives The goal of this study was to compare cochlear implant behavioral measures and electrically-evoked auditory brainstem responses (EABRs) obtained with a spatially focused electrode configuration. It has been shown previously that channels with high thresholds, when measured with the tripolar configuration, exhibit relatively broad psychophysical tuning curves (Bierer and Faulkner, 2010). The elevated threshold and degraded spatial/spectral selectivity of such channels are consistent with a poor electrode-neuron interface, such as suboptimal electrode placement or reduced nerve survival. However, the psychophysical methods required to obtain these data are time intensive and may not be practical during a clinical mapping procedure, especially for young children. Here we have extended the previous investigation to determine if a physiological approach could provide a similar assessment of channel functionality. We hypothesized that, in accordance with the perceptual measures, higher EABR thresholds would correlate with steeper EABR amplitude growth functions, reflecting a degraded electrode-neuron interface. Design Data were collected from six cochlear implant listeners implanted with the HiRes 90k cochlear implant (Advanced Bionics). Single-channel thresholds and most comfortable listening levels were obtained for stimuli that varied in presumed electrical field size by using the partial tripolar configuration, for which a fraction of current (σ) from a center active electrode returns through two neighboring electrodes and the remainder through a distant indifferent electrode. EABRs were obtained in each subject for the two channels having the highest and lowest tripolar (σ=1 or 0.9) behavioral threshold. Evoked potentials were measured with both the monopolar (σ=0) and a more focused partial tripolar (σ ≥ 0.50) configuration. Results Consistent with previous studies, EABR thresholds were highly and positively correlated with behavioral thresholds

  12. Complications after cardiac implantable electronic device implantations

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard

    2013-01-01

    Complications after cardiac implantable electronic device (CIED) treatment, including permanent pacemakers (PMs), cardiac resynchronization therapy devices with defibrillators (CRT-Ds) or without (CRT-Ps), and implantable cardioverter defibrillators (ICDs), are associated with increased patient...

  13. Report on the FY 1999 investigational survey on the activation of oxygen electrode by ion implantation; 1999 nendo ion chunyuho ni yoru sanso denkyoku no kasseika ni kansuru kenkyu chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    The oxygen electrode is important as the base electrode for water electrolysis and fuel cell, but to move it, overvoltage (activated energy) in addition to equilibrium voltage is necessary, which leads to the lowering of energy efficiency. By forming the active spot by ion implantation, the lowering of overvoltage was studied. The implantation of Ru{sup +} ion in Ruthenium dioxide thin film electrode reduced the oxygen generating overvoltage by 15-20mV. Even in the oxygen reduction, activity was also increased. The chemical composition of thin film does not change by ion implantation. The increase in activity is based on a physical change which is called the surface defect formation. The layer of ion implantation is composed of microcrystals, which is thought to contribute to the formation of any active spot. Ions were implanted in Pt electrode as a practical use material, and even in the oxygen reduction of Pt, a possibility of heightening activity by ion implantation was admitted even in the oxygen reduction of Pt. The generation of high activity oxygen by ion plantation and development of oxygen reduction electrode were established as one method as a rule. (NEDO)

  14. Evaluation of the tripolar electrode stimulation method by numerical analysis and animal experiments for cochlear implants.

    Science.gov (United States)

    Miyoshi, S; Sakajiri, M; Ifukube, T; Matsushima, J

    1997-01-01

    We have proposed the Tripolar Electrode Stimulation Method (TESM) which may enable us to narrow the stimulation region and to move continuously the stimulation site for the cochlear implants. We evaluated whether or not TESM works according to a theory based on numerical analysis using the auditory nerve fiber model. In this simulation, the sum of the excited model fibers were compared with the compound actions potentials obtained from animal experiments. As a result, this experiment showed that TESM could narrow a stimulation region by controlling the sum of the currents emitted from the electrodes on both sides, and continuously move a stimulation site by changing the ratio of the currents emitted from the electrodes on both sides.

  15. Seed Placement in Permanent Breast Seed Implant Brachytherapy: Are Concerns Over Accuracy Valid?

    Energy Technology Data Exchange (ETDEWEB)

    Morton, Daniel, E-mail: dmorton@bccancer.bc.ca [Department of Medical Physics, BC Cancer Agency, Centre for the Southern Interior, Kelowna, British Columbia (Canada); Department of Physics and Astronomy, University of Victoria, Victoria, British Columbia (Canada); Hilts, Michelle [Department of Medical Physics, BC Cancer Agency, Centre for the Southern Interior, Kelowna, British Columbia (Canada); Department of Physics and Astronomy, University of Victoria, Victoria, British Columbia (Canada); Batchelar, Deidre [Department of Medical Physics, BC Cancer Agency, Centre for the Southern Interior, Kelowna, British Columbia (Canada); Crook, Juanita [Department of Radiation Oncology, BC Cancer Agency, Centre for the Southern Interior, Kelowna, British Columbia (Canada)

    2016-07-01

    Purpose: To evaluate seed placement accuracy in permanent breast seed implant brachytherapy (PBSI), to identify any systematic errors and evaluate their effect on dosimetry. Methods and Materials: Treatment plans and postimplant computed tomography scans for 20 PBSI patients were spatially registered and used to evaluate differences between planned and implanted seed positions, termed seed displacements. For each patient, the mean total and directional seed displacements were determined in both standard room coordinates and in needle coordinates relative to needle insertion angle. Seeds were labeled according to their proximity to the anatomy within the breast, to evaluate the influence of anatomic regions on seed placement. Dosimetry within an evaluative target volume (seroma + 5 mm), skin, breast, and ribs was evaluated to determine the impact of seed placement on the treatment. Results: The overall mean (±SD) difference between implanted and planned positions was 9 ± 5 mm for the aggregate seed population. No significant systematic directional displacements were observed for this whole population. However, for individual patients, systematic displacements were observed, implying that intrapatient offsets occur during the procedure. Mean displacements for seeds in the different anatomic areas were not found to be significantly different from the mean for the entire seed population. However, small directional trends were observed within the anatomy, potentially indicating some bias in the delivery. Despite observed differences between the planned and implanted seed positions, the median (range) V{sub 90} for the 20 patients was 97% (66%-100%), and acceptable dosimetry was achieved for critical structures. Conclusions: No significant trends or systematic errors were observed in the placement of seeds in PBSI, including seeds implanted directly into the seroma. Recorded seed displacements may be related to intrapatient setup adjustments. Despite observed seed

  16. New Fabrication Method of Three-Electrode System on Cylindrical Capillary Surface as a Flexible Implantable Microneedle

    Science.gov (United States)

    Yang, Zhuoqing; Zhang, Yi; Itoh, Toshihiro; Maeda, Ryutaro

    2013-04-01

    In this present paper, a three-electrode system has been fabricated and integrated on the cylindrical polymer capillary surface by micromachining technology, which could be used as a flexible and implantable microneedle for glucose sensor application in future. A UV lithography system is successfully developed for high resolution alignment on cylindrical substrates. The multilayer alignment exposure for cylindrical polymer capillary substrate is for the first time realized utilizing the lithography system. The ±1 μm alignment precision has been realized on the 330 μm-outer diameter polymer capillary surface, on which the three-electrode structure consisting of two platinum electrodes and one Ag/AgCl reference electrode has been fabricated. The fabricated whole device as microneedle for glucose sensor application has been also characterized in 1 mol/L KCl and 0.02 mol/L K3Fe(CN)6 mix solution. The measured cyclic voltammetry curve shows that the prepared three-electrode system has a good redox property.

  17. Restoring speech perception with cochlear implants by spanning defective electrode contacts.

    Science.gov (United States)

    Frijns, Johan H M; Snel-Bongers, Jorien; Vellinga, Dirk; Schrage, Erik; Vanpoucke, Filiep J; Briaire, Jeroen J

    2013-04-01

    Even with six defective contacts, spanning can largely restore speech perception with the HiRes 120 speech processing strategy to the level supported by an intact electrode array. Moreover, the sound quality is not degraded. Previous studies have demonstrated reduced speech perception scores (SPS) with defective contacts in HiRes 120. This study investigated whether replacing defective contacts by spanning, i.e. current steering on non-adjacent contacts, is able to restore speech recognition to the level supported by an intact electrode array. Ten adult cochlear implant recipients (HiRes90K, HiFocus1J) with experience with HiRes 120 participated in this study. Three different defective electrode arrays were simulated (six separate defective contacts, three pairs or two triplets). The participants received three take-home strategies and were asked to evaluate the sound quality in five predefined listening conditions. After 3 weeks, SPS were evaluated with monosyllabic words in quiet and in speech-shaped background noise. The participants rated the sound quality equal for all take-home strategies. SPS with background noise were equal for all conditions tested. However, SPS in quiet (85% phonemes correct on average with the full array) decreased significantly with increasing spanning distance, with a 3% decrease for each spanned contact.

  18. Incidence and predictors of permanent pacemaker implantation following treatment with the repositionable Lotus™ transcatheter aortic valve.

    Science.gov (United States)

    Zaman, Sarah; McCormick, Liam; Gooley, Robert; Rashid, Hashrul; Ramkumar, Satish; Jackson, Damon; Hui, Samuel; Meredith, Ian T

    2017-07-01

    To determine the incidence and predictors of permanent pacemaker (PPM) requirement following transcatheter aortic valve replacement (TAVR) with the mechanically expanded Lotus TM Valve System (Boston Scientific). Pacemaker implantation is the most common complication following TAVR. Predictors of pacing following TAVR with the Lotus valve have not been systematically assessed. Consecutive patients with severe aortic stenosis who underwent Lotus valve implantation were prospectively recruited at a single-centre. Patients with a pre-existing PPM were excluded. Baseline ECG, echocardiographic and multiple detector computed tomography as well as procedural telemetry and depth of implantation were independently analyzed in a blinded manner. The primary endpoint was 30-day incidence of pacemaker requirement (PPM implantation or death while pacing-dependent). Multivariate analysis was performed to identify independent predictors of the primary endpoint. A total of 104 consecutive patients underwent TAVR with the Lotus valve with 9/104 (9%) with a pre-existing PPM excluded. New or worsened procedural LBBB occurred in 78%. Thirty-day incidence of the primary pacing endpoint was 28%. The most common indication for PPM implantation was complete heart block (CHB) (69%). Independent predictors of the primary endpoint included pre-existing RBBB (hazard ratio [HR] 2.8, 95% CI 1.1-7.0; P = 0.032) and depth of implantation below the noncoronary cusp (NCC) (HR 2.4, 95% CI 1.0-5.7; P = 0.045). Almost a third of Lotus valve recipients require pacemaker implantation within 30 days. The presence of pre-existing RBBB and the depth of prosthesis implantation below the NCC were significant pacing predictors. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  19. Implant of permanent pacemaker during acute coronary syndrome: Mortality and associated factors in the ARIAM registry.

    Science.gov (United States)

    Pola-Gallego-de-Guzmán, María Dolores; Ruiz-Bailén, Manuel; Martínez-Arcos, Maria-Angeles; Gómez-Blizniak, Artur; Castillo Rivera, Ana-Maria; Molinos, Jesus Cobo

    2018-04-01

    Patients with acute coronary syndrome complicated with high degree atrioventricular block still have a high mortality. A low percentage of these patients need a permanent pacemaker (PPM) but mortality and associated factors with the PPM implant in acute coronary syndrome patients are not known. We assess whether PPM implant is an independent variable in the mortality of acute coronary syndrome patients. Also, we explored the variables that remain independently associated with PPM implantation. This was an observational study on the Spanish ARIAM register. The inclusion period was from January 2001 to December 2011. This registry included all Andalusian acute coronary syndrome patients. Follow-up for global mortality was until November 2013. We selected 27,608 cases. In 62 patients a PPM was implanted (0.024%). The mean age in PPM patients was 70.71±11.214 years versus 64.46±12.985 years in patients with no PPM. PPM implant was associated independently with age (odds ratio (OR) 1.031, 95% confidence interval (CI) 1.007-1.055), with left ventricular branch block (OR 6.622, 95% CI 2.439-18.181), with any arrhythmia at intensive care unit admission (OR 2.754, 95% CI 1.506-5.025) and with heart failure (OR 3.344, 95% CI 1.78-8.333). PPM implant was independently associated with mortality (OR 11.436, 95% CI 1.576-83.009). In propensity score analysis PPM implant was still associated with mortality (OR 5.79, 95% CI 3.27-25.63). PPM implant is associated with mortality in the acute coronary syndrome population in the ARIAM registry. Advanced age, heart failure, arrhythmias and left ventricular branch block at intensive care unit admission were found associated factors with PPM implant in acute coronary syndrome patient.

  20. NOTE: Optimal needle arrangement for intraoperative planning in permanent I-125 prostate implants

    Science.gov (United States)

    Thompson, S. A.; Fung, A. Y. C.; Zaider, M.

    2002-08-01

    One limitation of intraoperative planning of permanent prostate implants is that needles must already be in the gland before planning images are acquired. Improperly placed needles often restrict the capability of generating optimal seed placement. We developed guiding principles for the proper layout of needles within the treatment volume. The Memorial Sloan-Kettering Cancer Center planning system employs a genetic algorithm to find the optimal seed implantation pattern consistent with pre-assigned constraints (needle geometry, uniformity, conformity and the avoidance of high doses to urethra and rectum). Ultrasound volumes for twelve patients with I-125 implants were used to generate six plans per patient (total 72 plans) with different needle arrangements. The plans were evaluated in terms of V100 (percentage prostate volume receiving at least the prescription dose), U135 (percentage urethra volume receiving at least 135% of prescription dose), and CI (conformity index, the ratio of treatment volume to prescription dose volume.) The method termed POSTCTR, in which needles were placed on the periphery of the largest ultrasound slice and posterior central needles were placed as needed, consistently gave superior results for all prostate sizes. Another arrangement, labelled POSTLAT, where the needles were placed peripherally with additional needles in the posterior lateral lobes, also gave satisfactory results. We advocate two needle arrangements, POSTCTR and POSTLAT, with the former giving better results.

  1. Identifying cochlear implant channels with poor electrode-neuron interfaces: electrically evoked auditory brain stem responses measured with the partial tripolar configuration.

    Science.gov (United States)

    Bierer, Julie Arenberg; Faulkner, Kathleen F; Tremblay, Kelly L

    2011-01-01

    The goal of this study was to compare cochlear implant behavioral measures and electrically evoked auditory brain stem responses (EABRs) obtained with a spatially focused electrode configuration. It has been shown previously that channels with high thresholds, when measured with the tripolar configuration, exhibit relatively broad psychophysical tuning curves. The elevated threshold and degraded spatial/spectral selectivity of such channels are consistent with a poor electrode-neuron interface, defined as suboptimal electrode placement or reduced nerve survival. However, the psychophysical methods required to obtain these data are time intensive and may not be practical during a clinical mapping session, especially for young children. Here, we have extended the previous investigation to determine whether a physiological approach could provide a similar assessment of channel functionality. We hypothesized that, in accordance with the perceptual measures, higher EABR thresholds would correlate with steeper EABR amplitude growth functions, reflecting a degraded electrode-neuron interface. Data were collected from six cochlear implant listeners implanted with the HiRes 90k cochlear implant (Advanced Bionics). Single-channel thresholds and most comfortable listening levels were obtained for stimuli that varied in presumed electrical field size by using the partial tripolar configuration, for which a fraction of current (σ) from a center active electrode returns through two neighboring electrodes and the remainder through a distant indifferent electrode. EABRs were obtained in each subject for the two channels having the highest and lowest tripolar (σ = 1 or 0.9) behavioral threshold. Evoked potentials were measured with both the monopolar (σ = 0) and a more focused partial tripolar (σ ≥ 0.50) configuration. Consistent with previous studies, EABR thresholds were highly and positively correlated with behavioral thresholds obtained with both the monopolar and partial

  2. Assessing the Electrode-Neuron Interface with the Electrically Evoked Compound Action Potential, Electrode Position, and Behavioral Thresholds.

    Science.gov (United States)

    DeVries, Lindsay; Scheperle, Rachel; Bierer, Julie Arenberg

    2016-06-01

    Variability in speech perception scores among cochlear implant listeners may largely reflect the variable efficacy of implant electrodes to convey stimulus information to the auditory nerve. In the present study, three metrics were applied to assess the quality of the electrode-neuron interface of individual cochlear implant channels: the electrically evoked compound action potential (ECAP), the estimation of electrode position using computerized tomography (CT), and behavioral thresholds using focused stimulation. The primary motivation of this approach is to evaluate the ECAP as a site-specific measure of the electrode-neuron interface in the context of two peripheral factors that likely contribute to degraded perception: large electrode-to-modiolus distance and reduced neural density. Ten unilaterally implanted adults with Advanced Bionics HiRes90k devices participated. ECAPs were elicited with monopolar stimulation within a forward-masking paradigm to construct channel interaction functions (CIF), behavioral thresholds were obtained with quadrupolar (sQP) stimulation, and data from imaging provided estimates of electrode-to-modiolus distance and scalar location (scala tympani (ST), intermediate, or scala vestibuli (SV)) for each electrode. The width of the ECAP CIF was positively correlated with electrode-to-modiolus distance; both of these measures were also influenced by scalar position. The ECAP peak amplitude was negatively correlated with behavioral thresholds. Moreover, subjects with low behavioral thresholds and large ECAP amplitudes, averaged across electrodes, tended to have higher speech perception scores. These results suggest a potential clinical role for the ECAP in the objective assessment of individual cochlear implant channels, with the potential to improve speech perception outcomes.

  3. Current steering and current focusing in cochlear implants: comparison of monopolar, tripolar, and virtual channel electrode configurations.

    NARCIS (Netherlands)

    Berenstein, C.K.; Mens, L.H.M.; Mulder, J.J.S.; Vanpoucke, F.J.

    2008-01-01

    OBJECTIVES: To compare the effects of Monopole (Mono), Tripole (Tri), and "Virtual channel" (Vchan) electrode configurations on spectral resolution and speech perception in a crossover design. DESIGN: Nine experienced adults who received an Advanced Bionics CII/90K cochlear implant participated in a

  4. Occupational exposure in prostate permanent implants with I-125 seeds

    Energy Technology Data Exchange (ETDEWEB)

    Fdez Garcia, J.; Luna, V.; Sancho, J. M. g.; Martinez, J.; Galiano, P. S.; Jimenez, I.; Prada, P.; Juan, G.; Vivanco, J.

    2002-07-01

    Prostate brachytherapy is one of the techniques increasing faster in the environment of the radiotherapy and will probably go on increasing in the future. There are two forms in their use; by means of remote afterloading high dose rate (HDR) with Ir-192 radioactive sources or by means of permanent implant by manual/automatic afterloading of low dose rate (LDR) with seeds of I-125 or Pd-103. Iodine-125 has a half life of 59.4 days and it decays by electron capture with emissions of characteristic photons and electrons. The electrons are absorbed by the titanium wall of the I-125 seed. The principal photon emissions are 27.4 and 31.4 keV X-rays and a 35.5 keV gamma ray. Besides 22.1 and 25.2 keV fluorescent X-rays are also emitted resulting from interactions of the iodine-125 photons with the silver rod. The resulting average photon energy is approximately 27.4 keV. (Author)

  5. Influence of breast composition and interseed attenuation in dose calculations for post-implant assessment of permanent breast 103Pd seed implant

    International Nuclear Information System (INIS)

    Afsharpour, Hossein; Beaulieu, Luc; Pignol, Jean-Philippe; Keller, Brian; Carrier, Jean-Francois; Reniers, Brigitte; Verhaegen, Frank

    2010-01-01

    The impact of tissue heterogeneity and interseed attenuation is studied in post-implant evaluation of five clinical permanent breast 103 Pd seed implants using the Monte Carlo (MC) dose calculation method. Dose metrics for the target (PTV) as well as an organ at risk (skin) are used to visualize the differences between a TG43-like MC method and more accurate MC methods capable of considering the breast tissue heterogeneity as well as the interseed attenuation. PTV dose is reduced when using a breast tissue model instead of water in MC calculations while the dose to the skin is increased. Furthermore, we investigate the effect of varying the glandular/adipose proportion of the breast tissue on dose distributions. The dose to the PTV (skin) decreases (increases) with the increasing adipose proportion inside the breast. In a complete geometry and compared to a TG43-like situation, the average PTV D 90 reduction varies from 3.9% in a glandular breast to 35.5% when the breast consists entirely of adipose. The skin D 10 increases by 28.2% in an entirely adipose breast. The results of this work show the importance of an accurate and patient-dependent breast tissue model to be used in the dosimetry for this kind of low energy implant.

  6. Investigation on curative efficacy for malignant tumor by implantation '125I permanent brachytherapy seeds

    International Nuclear Information System (INIS)

    Hu Shu; Gao Zhou; Jia Shaowei; Cheng Xianyi; Chen Junhui; Yin Weihua; Sun Desheng

    2011-01-01

    Twenty inpatients suffered from malignant tumors with twenty-four lesions were treated with 125 I permanent brachytherapy seed in Peking University Shenzhen Hospital, and the feasibility, curative effect and adverse effect of the treatment were observed. Before 125 I seeds implantation, the three-dimensional treatment planning was preconcerted. There were two methods to implant 125 I seeds. One was to insert the seeds in the location of residual focus and metastatic lesions of the tumors directly in ordinary operations or through laparoscopy under general anesthesia. The other w as to implant the seeds into the tumors through percutaneous needles by the guidance of CT scanning or color doppler ultrasonography under local anesthesia. The implantations for all of the 20 patients (24 lesions) were performed successfully. During and one week after the implantation, the distributions of the planted seeds were approximately the same as the scheduled three-dimensional treatment planning, and no seed migration was found. Adverse reactions during and after the operation were slight and recovered after correlative treatments. Clinical symptoms were palliated and ser um tumor marker decreased to a different extent among most patients. The complete remission (CR) rate is 20.00% (4/20 patients ), the partial emission (PR) rate is 35.00% (7/20 patients), the stable disease (SD) rate is 30.00% (6/20 patients), the progressive disease (PD) rate is 15.00% (3/20 patients), and the overall response rate (CR + PR) is 53.33% (8 patients). 125 I seeds implantation for targeted therapy is convenient, safe and effective on malignant tumor, and is well worth advanced application. (authors)

  7. Iodine-125 seed implantation (permanent brachytherapy) for clinically localized prostate cancer

    International Nuclear Information System (INIS)

    Ebara, Shin; Katayama, Yoshihisa; Tanimoto, Ryuta

    2008-01-01

    From January 2004 to March 2007, 308 patients with clinically localized prostate cancer were treated using iodine-125 ( 125 I) seed implantation (permanent brachytherapy) at Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences. We evaluated the treatment's efficacy and morbidity in 300 prostate cancer patients who were followed up for more than 1 month after brachytherapy. Based on the National Comprehensive Cancer Network (NCCN) guidelines, patients with a prostate volume of less than 40 ml in transrectal ultrasound imaging were classified as low or intermediate risk. The median patient age was 67 years (range 50 to 79 years), the median prostate-specific antigen (PSA) value before biopsy was 6.95 ng/ml (range 1.13 to 24.7 ng/ml), and the median prostate volume was 24.33 ml (range 9.3 to 41.76 ml). The median follow-up was 18 months (range 1 to 36 months) and the PSA levels decreased in almost all patients after brachytherapy. Although 194 of 300 patients (64.7%) complained of difficulty in urination, pollakisuria/urgency, miction pain, and/or urinary incontinence, all of which might be associated with radiation prostatitis during the first month after brachytherapy, these symptoms gradually improved. 125 I seed implantation brachytherapy is safe and effective for localized prostate cancer within short-term follow up. (author)

  8. Long-term implantation of deep brain stimulation electrodes in the pontine micturition centre of the Göttingen minipig.

    Science.gov (United States)

    Jensen, Kristian N; Deding, Dorthe; Sørensen, Jens Christian; Bjarkam, Carsten R

    2009-07-01

    To implant deep brain stimulation (DBS) electrodes in the porcine pontine micturition centre (PMC) in order to establish a large animal model of PMC-DBS. Brain stems from four Göttingen minipigs were sectioned coronally into 40-mum-thick histological sections and stained with Nissl, auto-metallographic myelin stain, tyrosine hydroxylase and corticotrophin-releasing factor immunohistochemistry in order to identify the porcine PMC. DBS electrodes were then stereotaxically implanted on the right side into the PMC in four Göttingen minipigs, and the bladder response to electrical stimulation was evaluated by subsequent cystometry performed immediately after the operation and several weeks later. A paired CRF-dense area homologous to the PMC in other species was encountered in the rostral pontine tegmentum medial to the locus coeruleus and ventral to the floor of the fourth ventricle. Electrical stimulation of the CRF-dense area resulted in an increased detrusor pressure followed by visible voiding in some instances. The pigs were allowed to survive between 14 and 55 days, and electrical stimulation resulting in an increased detrusor pressure was performed on more than one occasion without affecting consciousness or general thriving. None of the pigs developed postoperative infections or died prematurely. DBS electrodes can be implanted for several weeks in the identified CRF-dense area resulting in a useful large animal model for basic research on micturition and the future clinical use of this treatment modality in neurogenic supra-pontine voiding disorders.

  9. Improved 2-D resistivity imaging of features in covered karst terrain with arrays of implanted electrodes

    Science.gov (United States)

    Kiflu, H. G.; Kruse, S. E.; Harro, D.; Loke, M. H.; Wilkinson, P. B.

    2013-12-01

    Electrical resistivity tomography is commonly used to identify geologic features associated with sinkhole formation. In covered karst terrain, however, it can be difficult to resolve the depth to top of limestone with this method. This is due to the fact that array lengths, and hence depth of resolution, are often limited by residential or commercial lot dimensions in urban environments. Furthermore, the sediments mantling the limestone are often clay-rich and highly conductive. The resistivity method has limited sensitivity to resistive zones beneath conductive zones. This sensitivity can be improved significantly with electrodes implanted at depth in the cover sediments near the top of limestone. An array of deep electrodes is installed with direct push technology in the karst cover. When combined with a surface array in which each surface electrode is underlain by a deep electrode, the array geometry is similar to a borehole array turned on its side. This method, called the Multi-Electrode Resistivity Implant Technique (MERIT), offers the promise of significantly improved resolution of epikarst and cover collapse development zones in the overlying sediment, the limestone or at the sediment-bedrock interface in heterogeneous karst environments. With a non-traditional array design, the question of optimal array geometries arises. Optimizing array geometries is complicated by the fact that many plausible 4-electrode readings will produce negative apparent resistivity values, even in homogeneous terrain. Negative apparent resistivities cannot be used in inversions based on the logarithm of the apparent resistivity. New algorithms for seeking optimal array geometries have been developed by modifying the 'Compare R' method of Wilkinson and Loke. The optimized arrays show significantly improved resolution over basic arrays adapted from traditional 2D surface geometries. Several MERIT case study surveys have been conducted in covered karst in west-central Florida, with

  10. In vivo monitoring of glial scar proliferation on chronically implanted neural electrodes by fiber optical coherence tomography

    Science.gov (United States)

    Xie, Yijing; Martini, Nadja; Hassler, Christina; Kirch, Robert D.; Stieglitz, Thomas; Seifert, Andreas; Hofmann, Ulrich G.

    2014-01-01

    In neural prosthetics and stereotactic neurosurgery, intracortical electrodes are often utilized for delivering therapeutic electrical pulses, and recording neural electrophysiological signals. Unfortunately, neuroinflammation impairs the neuron-electrode-interface by developing a compact glial encapsulation around the implants in long term. At present, analyzing this immune reaction is only feasible with post-mortem histology; currently no means for specific in vivo monitoring exist and most applicable imaging modalities can not provide information in deep brain regions. Optical coherence tomography (OCT) is a well established imaging modality for in vivo studies, providing cellular resolution and up to 1.2 mm imaging depth in brain tissue. A fiber based spectral domain OCT was shown to be capable of minimally invasive brain imaging. In the present study, we propose to use a fiber based spectral domain OCT to monitor the progression of the tissue's immune response through scar encapsulation progress in a rat animal model. A fine fiber catheter was implanted in rat brain together with a flexible polyimide microelectrode in sight both of which acts as a foreign body and induces the brain tissue immune reaction. OCT signals were collected from animals up to 12 weeks after implantation and thus gliotic scarring in vivo monitored for that time. Preliminary data showed a significant enhancement of the OCT backscattering signal during the first 3 weeks after implantation, and increased attenuation factor of the sampled tissue due to the glial scar formation. PMID:25191264

  11. A Radiation Badge Survey for Family Members Living With Patients Treated With a 103Pd Permanent Breast Seed Implant

    International Nuclear Information System (INIS)

    Keller, Brian M.; Pignol, Jean-Philippe; Rakovitch, Eileen; Sankreacha, Raxa; O'Brien, Peter

    2008-01-01

    Purpose: Sixty-seven patients with early-stage breast cancer were treated in a Phase I/II clinical trial using a 103 Pd permanent breast seed implant as adjuvant radiotherapy after breast-conserving surgery. We report the dose received by family members living with these patients and compare measured doses with theoretical worst-case scenario estimates. Methods and Materials: Exposure-rate measurements were taken at 1 m from the patient by using a calibrated low-energy survey meter. Landauer (Landauer Inc., Glenwood, IL) Luxel badges, with sensitivity of 0.01 mSv, were given to family members to wear after the implantation. Badge readings for 33 spouses and 28 other family members were used to estimate effective doses, and these were compared with theory. Results: Average preimplantation planning target volume from computed tomography was 50.3 ml (range, 18.0-96.7 ml), and average preimplantation distance between the skin and the most anterior planning target volume margin was 0.57 cm. The average maximum exposure rate was measured to be 2.4 ± 1.1 mR/h, and average measured dose to a spouse was 0.99 ± 1.0 mSv. The calculated exposure rates and spousal doses using preimplantation computed tomography scan data overestimated those measured. Average measured family member dose (excluding spouses) was 0.20 ± 0.58 mSv. Conclusions: Based on measured and calculated spousal doses, a permanent breast seed implant using 103 Pd is safe for the public. However, it is recommended that extra precautions in the way of a breast patch be used when patients with an implant will be in the vicinity of toddlers or pregnant women

  12. Evaluation of permanent I-125 prostate implants using radiography and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Moerland, Marinus A.; Wijrdeman, Harm K.; Beersma, Robert; Bakker, Chris J.G.; Battermann, Jan J.

    1997-01-01

    Purpose: The aim of this study is the evaluation of permanent I-125 prostate implants using radiography and magnetic resonance imaging (MRI). Methods and Materials: Twenty-one patients underwent radiography on the simulator and MRI within 3 days after implantation of the I-125 seeds. Isocentric radiographs were used for reconstruction of the seed distribution, after which registration with the seed-induced signal voids on MRI provided the seed positions in relation to the prostate. The prostate was contoured on the transversal magnetic resonance images, and dose-volume histograms were computed to evaluate the implants. The validity of the ellipsoidal prostate volume approximation, as applied in preimplant dose calculation, was assessed by comparison of ellipsoidal volumes given by prostate width, height, and length and prostate volumes obtained by a slice-by-slice contouring method, both on postimplant MRI. Prostate volume changes due to postimplant prostate swelling were assessed from radiographs taken at 3 days and 1 month after the implantation. Results: The seeds were readily identified on T 1 -weighted spin-echo images and matched with the seed distribution reconstructed from the isocentric radiographs. The matching error, averaged over 21 patients, amounted to 1.8 ± 0.4 mm (mean ± standard deviation). The fractions of the prostate volumes receiving the prescribed matched peripheral dose (MPD) ranged from 32 to 71% (mean ± standard deviation: 60 ± 10%). Prostate volumes, obtained by the contouring method on postimplant MRI, were a factor 1.5 ± 0.3 larger than the ellipsoidal volumes given by the prostate dimensions on postimplant MRI. Prostate volumes 3 days after the implantation were a factor 1.3 ± 0.2 larger than the prostate volumes 1 month after the implantation. Registration of the reconstructed seed distribution and the MR images showed inaccuracies in seed placement, for example, two or more seeds clustering together or seeds outside the prostate

  13. Pulmonary embolization of permanently implanted radioactive palladium-103 seeds for carcinoma of the prostate

    International Nuclear Information System (INIS)

    Nag, Subir; Vivekanandam, Singhavajhala; Martinez-Monge, Rafael

    1997-01-01

    Purpose: It has been reported that permanently implanted iodine-125 seeds can embolize to the lungs. There is little data on the embolization of palladium-103 seeds. The purpose of this study is to collect and evaluate data on the embolization of Pd-103 seeds. Methods and Materials: The records of 112 patients implanted with Pd-103 for carcinoma of the prostate were reviewed to systemically study the incidence and dynamics of pulmonary embolism of Pd-103 seeds. Five patients had no postoperative chest radiograph and were thus excluded, leaving 107 patients for review. Results: Chest radiographs of 19 of the 107 patients showed embolized seeds in the lungs (18%). Two patients had three seeds each, nine patients had two seeds each; and in the remaining eight patients, a single seed migrated to the lungs. The seeds migrated mainly (84%) to the lower lobes. None of the eight patients who had their first postoperative chest radiograph on the day of the implant showed any embolized seeds. The embolized seed appeared only on subsequent chest radiographs taken 27 to 40 days later. Ten of the other 11 patients who had their first radiograph 1 to 97 days after brachytherapy had embolized seeds on their first chest radiograph. In the other patient, the embolized seed appeared only on a subsequent chest radiograph taken after 127 days. There were no clinical pulmonary or cardiac effects evident on routine follow-up of these patients with pulmonary embolized seeds. Conclusion: Embolization of Pd-103 seeds to the lungs after implantation for carcinoma of the prostate is an unusual event. In this study only 0.3% of the seeds implanted migrated to the lungs. Although it was previously thought that pulmonary seed migration mainly occurred on the day of brachytherapy, our experience shows that seeds usually migrated to the lungs after the day of the implant. There were no clinical pulmonary or cardiac effects attributable to embolized seeds in the lungs on routine follow-up

  14. Chronic implantation of cuff electrodes on the pelvic nerve in rats is well tolerated and does not compromise afferent or efferent fibre functionality

    Science.gov (United States)

    Crook, J. J.; Brouillard, C. B. J.; Irazoqui, P. P.; Lovick, T. A.

    2018-04-01

    Objective. Neuromodulation of autonomic nerve activity to regulate physiological processes is an emerging field. Vagal stimulation has received most attention whereas the potential of modulate visceral function by targeting autonomic nerves within the abdominal cavity remains under-exploited. Surgery to locate intra-abdominal targets is inherently more stressful than for peripheral nerves. Electrode leads risk becoming entrapped by intestines and loss of functionality in the nerve-target organ connection could result from electrode migration or twisting. Since nociceptor afferents are intermingled with similar-sized visceral autonomic fibres, stimulation may induce pain. In anaesthetised rats high frequency stimulation of the pelvic nerve can suppress urinary voiding but it is not known how conscious animals would react to this procedure. Our objective therefore was to determine how rats tolerated chronic implantation of cuff electrodes on the pelvic nerve, whether nerve stimulation would be aversive and whether nerve-bladder functionality would be compromised. Approach. We carried out a preliminary de-risking study to investigate how conscious rats tolerated chronic implantation of electrodes on the pelvic nerve, their responsiveness to intermittent high frequency stimulation and whether functionality of the nerve-bladder connection became compromised. Main results. Implantation of cuff electrodes was well-tolerated. The normal diurnal pattern of urinary voiding was not disrupted. Pelvic nerve stimulation (up to 4 mA, 3 kHz) for 30 min periods evoked mild alerting at stimulus onset but no signs of pain. Stimulation evoked a modest (nerve temperature but the functional integrity of the nerve-bladder connection, reflected by contraction of the detrusor muscle in response to 10 Hz nerve stimulation, was not compromised. Significance. Chronic implantation of cuff electrodes on the pelvic nerve was found to be a well-tolerated procedure in rats and high frequency

  15. Experimental evaluation of an online gamma-camera imaging of permanent seed implantation (OGIPSI) prototype for partial breast irradiation

    International Nuclear Information System (INIS)

    Ravi, Ananth; Caldwell, Curtis B.; Pignol, Jean-Philippe

    2008-01-01

    Previously, our team used Monte Carlo simulation to demonstrate that a gamma camera could potentially be used as an online image guidance device to visualize seeds during permanent breast seed implant procedures. This could allow for intraoperative correction if seeds have been misplaced. The objective of this study is to describe an experimental evaluation of an online gamma-camera imaging of permanent seed implantation (OGIPSI) prototype. The OGIPSI device is intended to be able to detect a seed misplacement of 5 mm or more within an imaging time of 2 min or less. The device was constructed by fitting a custom built brass collimator (16 mm height, 0.65 mm hole pitch, 0.15 mm septal thickness) on a 64 pixel linear array CZT detector (eValuator-2000, eV Products, Saxonburg, PA). Two-dimensional projection images of seed distributions were acquired by the use of a digitally controlled translation stage. Spatial resolution and noise characteristics of the detector were measured. The ability and time needed for the OGIPSI device to image the seeds and to detect cold spots was tested using an anthropomorphic breast phantom. Mimicking a real treatment plan, a total of 52 103 Pd seeds of 65.8 MBq each were placed on three different layers at appropriate depths within the phantom. The seeds were reliably detected within 30 s with a median error in localization of 1 mm. In conclusion, an OGIPSI device can potentially be used for image guidance of permanent brachytherapy applications in the breast and, possibly, other sites

  16. Evaluating cochlear implant trauma to the scala vestibuli.

    Science.gov (United States)

    Adunka, O; Kiefer, J; Unkelbach, M H; Radeloff, A; Gstoettner, W

    2005-04-01

    Placement of cochlear implant electrodes into the scala vestibuli may be intentional, e.g. in case of blocked scala tympani or unintentional as a result of trauma to the basilar membrane or erroneous location of the cochieostomy. The aim of this study was to evaluate the morphological consequences and cochlear trauma after implantation of different cochlear implant electrode arrays in the scala vestibuli. Human temporal bone study with histological and radiological evaluation. Twelve human cadaver temporal bones were implanted with different cochlear implant electrodes. Implanted bones were processed using a special method to section undecalcified bone. Cochlear trauma and intracochlear positions. All implanted electrodes were implanted into the scala vestibuli using a special approach that allows direct scala vestibuli insertions. Fractures of the osseous spiral lamina were evaluated in some bones in the basal cochlear regions. In most electrodes, delicate structures of the organ of Corti were left intact, however, Reissner's membrane was destroyed in all specimens and the electrode lay upon the tectorial membrane. In some bones the organ of Corti was destroyed. Scala vestibuli insertions did not cause severe trauma to osseous or neural structures, thus preserving the basis for electrostimulation of the cochlea. However, destruction of Reissner's membrane and impact on the Organ of Corti can be assumed to destroy residual hearing.

  17. Surgical implications of perimodiolar cochlear implant electrode design: avoiding intracochlear damage and scala vestibuli insertion.

    Science.gov (United States)

    Briggs, R J; Tykocinski, M; Saunders, E; Hellier, W; Dahm, M; Pyman, B; Clark, G M

    2001-09-01

    To review the mechanisms and nature of intracochlear damage associated with cochlear implant electrode array insertion, in particular, the various perimodiolar electrode designs. Make recommendations regarding surgical techniques for the Nucleus Contour electrode to ensure correct position and minimal insertion trauma. The potential advantages of increased modiolar proximity of intracochlear multichannel electrode arrays are a reduction in stimulation thresholds, an increase in dynamic range and more localized neural excitation. This may improve speech perception and reduce power consumption. These advantages may be negated if increased intracochlear damage results from the method used to position the electrodes close to the modiolus. A review of the University of Melbourne Department of Otolaryngology experience with temporal bone safety studies using the Nucleus standard straight electrode array and a variety of perimodiolar electrode array designs; comparison with temporal bone insertion studies from other centres and postmortem histopathology studies reported in the literature. Review of our initial clinical experience using the Nucleus Contour electrode array. The nature of intracochlear damage resulting from electrode insertion trauma ranges from minor, localized, spiral ligament tear to diffuse organ of Corti disruption and osseous spiral lamina fracture. The type of damage depends on the mechanical characteristics of the electrode array, the stiffness, curvature and size of the electrode in relation to the scala, and the surgical technique. The narrow, flexible, straight arrays are the least traumatic. Pre-curved or stiffer arrays are associated with an incidence of basilar membrane perforation. The cochleostomy must be correctly sited in relation to the round window to ensure scala tympani insertion. A cochleostomy anterior to the round window rather than inferior may lead to scala media or scala vestibuli insertion. Proximity of electrodes to the modiolus

  18. Symmetric Electrode Spanning Narrows the Excitation Patterns of Partial Tripolar Stimuli in Cochlear Implants.

    Science.gov (United States)

    Luo, Xin; Wu, Ching-Chih

    2016-12-01

    In cochlear implants (CIs), standard partial tripolar (pTP) mode reduces current spread by returning a fraction of the current to two adjacent flanking electrodes within the cochlea. Symmetric electrode spanning (i.e., separating both the apical and basal return electrodes from the main electrode by one electrode) has been shown to increase the pitch of pTP stimuli, when the ratio of intracochlear return current was fixed. To explain the pitch increase caused by symmetric spanning in pTP mode, this study measured the electrical potentials of both standard and symmetrically spanned pTP stimuli on a main electrode EL8 in five CI ears using electrical field imaging (EFI). In addition, the spatial profiles of evoked compound action potentials (ECAP) and the psychophysical forward masking (PFM) patterns were also measured for both stimuli. The EFI, ECAP, and PFM patterns of a given stimulus differed in shape details, reflecting the different levels of auditory processing and different ratios of intracochlear return current across the measurement methods. Compared to the standard pTP stimuli, the symmetrically spanned pTP stimuli significantly reduced the areas under the curves of the normalized EFI and PFM patterns, without shifting the pattern peaks and centroids (both around EL8). The more focused excitation patterns with symmetric spanning may have caused the previously reported pitch increase, due to an interaction between pitch and timbre perception. Being able to reduce the spread of excitation, pTP mode symmetric spanning is a promising stimulation strategy that may further increase spectral resolution and frequency selectivity with CIs.

  19. Low Cost Electrode Assembly for EEG Recordings in Mice

    Directory of Open Access Journals (Sweden)

    Emily C. Vogler

    2017-11-01

    Full Text Available Wireless electroencephalography (EEG of small animal subjects typically utilizes miniaturized EEG devices which require a robust recording and electrode assembly that remains in place while also being well-tolerated by the animal so as not to impair the ability of the animal to perform normal living activities or experimental tasks. We developed simple and fast electrode assembly and method of electrode implantation using electrode wires and wire-wrap technology that provides both higher survival and success rates in obtaining recordings from the electrodes than methods using screws as electrodes. The new wire method results in a 51% improvement in the number of electrodes that successfully record EEG signal. Also, the electrode assembly remains affixed and provides EEG signal for at least a month after implantation. Screws often serve as recording electrodes, which require either drilling holes into the skull to insert screws or affixing screws to the surface of the skull with adhesive. Drilling holes large enough to insert screws can be invasive and damaging to brain tissue, using adhesives may interfere with conductance and result in a poor signal, and soldering screws to wire leads results in fragile connections. The methods presented in this article provide a robust implant that is minimally invasive and has a significantly higher success rate of electrode implantation. In addition, the implant remains affixed and produces good recordings for over a month, while using economical, easily obtained materials and skills readily available in most animal research laboratories.

  20. Plasma immersion ion implantation of the interior surface of a large cylindrical bore using an auxiliary electrode

    International Nuclear Information System (INIS)

    Zeng, X.C.; Kwok, T.K.; Liu, A.G.; Chu, P.K.; Tang, B.Y.

    1998-01-01

    A model utilizing cold, unmagnetized, and collisionless fluid ions as well as Boltzmann electrons is used to comprehensively investigate the sheath expansion into a translationally invariant large bore in the presence of an auxiliary electrode during plasma immersion ion implantation (PIII) of a cylindrical bore sample. The governing equation of ion continuity, ion motion, and Poisson close-quote s equation are solved by using a numerical finite difference method for different cylindrical bore radii, auxiliary electrode radii, and voltage rise times. The ion density and ion impact energy at the cylindrical inner surface, as well as the ion energy distribution, maximum ion impact energy, and average ion impact energy for the various cases are obtained. Our results show a dramatic improvement in the impact energy when an auxiliary electrode is used and the recommended normalized auxiliary electrode radius is in the range of 0.1 endash 0.3. copyright 1998 American Institute of Physics

  1. SU-E-J-166: Sensitivity of Clinically Relevant Dosimetric Parameters to Contouring Uncertainty During Post Implant Dosimetry of Prostate Permanent Seed Implants

    Energy Technology Data Exchange (ETDEWEB)

    Mashouf, S [Sunnybrook Odette Cancer Centre, Toronto, ON (Canada); University of Toronto, Dept. of Radiation Oncology, Toronto, ON (Canada); Ravi, A; Morton, G; Song, W [Sunnybrook Odette Cancer Centre, Toronto, ON (Canada); University of Toronto, Dept. of Radiation Oncology, Toronto, ON (Canada); Sunnybrook Research Institute, Toronto, ON (Canada)

    2015-06-15

    Purpose: There is a strong evidence relating post-implant dosimetry for permanent seed prostate brachytherpy to local control rates. The delineation of the prostate on CT images, however, represents a challenge as it is difficult to confidently identify the prostate borders from soft tissue surrounding it. This study aims at quantifying the sensitivity of clinically relevant dosimetric parameters to prostate contouring uncertainty. Methods: The post-implant CT images and plans for a cohort of 43 patients, who have received I–125 permanent prostate seed implant in our centre, were exported to MIM Symphony LDR brachytherapy treatment planning system (MIM Software Inc., Cleveland, OH). The prostate contours in post-implant CT images were expanded/contracted uniformly for margins of ±1.00mm, ±2.00mm, ±3.00mm, ±4.00mm and ±5.00mm (±0.01mm). The values for V100 and D90 were extracted from Dose Volume Histograms for each contour and compared. Results: The mean value of V100 and D90 was obtained as 92.3±8.4% and 108.4±12.3% respectively (Rx=145Gy). V100 was reduced by −3.2±1.5%, −7.2±3.0%, −12.8±4.0%, −19.0±4.8%, − 25.5±5.4% for expanded contours of prostate with margins of +1mm, +2mm, +3mm, +4mm, and +5mm, respectively, while it was increased by 1.6±1.2%, 2.4±2.4%, 2.7±3.2%, 2.9±4.2%, 2.9±5.1% for the contracted contours. D90 was reduced by −6.9±3.5%, −14.5±6.1%, −23.8±7.1%, − 33.6±8.5%, −40.6±8.7% and increased by 4.1±2.6%, 6.1±5.0%, 7.2±5.7%, 8.1±7.3% and 8.1±7.3% for the same set of contours. Conclusion: Systematic expansion errors of more than 1mm may likely render a plan sub-optimal. Conversely contraction errors may Result in labeling a plan likely as optimal. The use of MRI images to contour the prostate should results in better delineation of prostate organ which increases the predictive value of post-op plans. Since observers tend to overestimate the prostate volume on CT, compared with MRI, the impact of the

  2. Tolerance and Acceptance Results of a Palladium-103 Permanent Breast Seed Implant Phase I/II Study

    International Nuclear Information System (INIS)

    Pignol, Jean-Philippe; Rakovitch, Eileen; Keller, Brian M.; Sankreacha, Raxa; Chartier, Carole

    2009-01-01

    Purpose: To test, in a prospective Phase I/II trial, a partial breast irradiation technique using a 103 Pd permanent breast seed implant (PBSI) realized in a single 1-h procedure under sedation and local freezing. Methods and Materials: Eligible patients had infiltrating ductal carcinoma ≤3 cm in diameter, surgical margin ≥2 mm, no extensive intraductal component, no lymphovascular invasion, and negative lymph nodes. Patients received a permanent seed implant, and a minimal peripheral dose of 90 Gy was prescribed to the clinical target volume, with a margin of 1.5 cm. Results: From May 2004 to April 2007, 67 patients received the PBSI treatment. The procedure was well tolerated, with 17% of patients having significant pain after the procedure. Only 1 patient (1.5%) had an acute skin reaction (Grade 3 according to the National Cancer Institute Common Toxicity Criteria). The rates of acute moist desquamation, erythema, and indurations were 10.4%, 42%, and 27%, respectively. At 1 year the rate of Grade 1 telangiectasia was 14%. The rate of skin reaction decreased from 65% to 28% when skin received less than the 85% isodose. According to a Radiation Therapy Oncology Group questionnaire, 80-90% of patients were very satisfied with their treatment, and the remainder were satisfied. One patient (1.5%) developed an abscess, which resolved after the use of antibiotics. There was no recurrence after a median follow-up of 32 months (range, 11-49 months). Conclusions: The feasibility, safety, and tolerability of PBSI compares favorably with that of external beam and other partial breast irradiation techniques.

  3. Class solution for inversely planned permanent prostate implants to mimic an experienced dosimetrist

    International Nuclear Information System (INIS)

    Lessard, Etienne; Kwa, Stefan L. S.; Pickett, Barby; Roach, Mach III; Pouliot, Jean

    2006-01-01

    The purpose of this paper is to present a method for the selection of inverse planning parameters and to establish a set of inverse planning parameters (class solution) for the inverse planning included in a commercial permanent prostate implant treatment planning system. The manual planning of more than 750 patients since 1996 led to the establishment of general treatment planning rules. A class solution is tuned to fulfill the treatment planning rules and generate equivalent implants. For ten patients, the inverse planning is compared with manual planning performed by our experienced physicist. The prostate volumes ranged from 17 to 51 cc and are implanted with low activity I-125 seeds. Dosimetric indices are calculated for comparison. The inverse planning needed about 15 s for each optimization (400 000 iterations on a 2.5 GHz PC). In comparison, the physicist needed about 20 min to perform each manual plan. A class solution is found that consistently produces dosimetric indices equivalent or better than the manual planning. Moreover, even with strict seed placement rules, the inverse planning can produce adequate prostate dose coverage and organ at risk protection. The inverse planning avoids implant with seeds outside of the prostate and too close to the urethra. It also avoids needles with only one seed and needles with three consecutive seeds. This reduces the risk of complication due to seed misplacement and edema. The inverse planning also uses a smaller number of needles, reducing the cause of trauma. The quality of the treatment plans is independent of the gland size and shape. A class solution is established that consistently and rapidly produces equivalent dosimetric indices as manual planning while respecting severe seed placement rules. The class solution can be used as a starting point for every patient, dramatically reducing the time needed to plan individual patient treatments. The class solution works with inverse preplanning, intraoperative

  4. First report of a permanent breast 103Pd seed implant as adjuvant radiation treatment for early-stage breast cancer

    International Nuclear Information System (INIS)

    Pignol, Jean-Philippe; Keller, Brian; Rakovitch, Eileen; Sankreacha, Raxa; Easton, Harry; Que, William

    2006-01-01

    Purpose: A new technique of adjuvant partial breast irradiation using 103 Pd permanent breast seed implants (PBSI) is presented. The procedure is performed in a single 1-hour session under local anesthesia. Methods and Materials: Patients referred to a single institution for adjuvant radiotherapy after lumpectomy for an infiltrating ductal carcinoma ≤3 cm in diameter, surgical margin ≥2 mm, no extensive in situ carcinoma, no lymphovascular invasion, and minimal or negative lymph node involvement were offered a PBSI. Results: Between May and December 2004, 31 eligible patients underwent CT scan and ultrasound simulations assessing PBSI feasibility. Fifteen were excluded because of feasibility issues, and 16 received PBSI. A minimal peripheral dose of 90 Gy was prescribed to the planning target volume corresponding to the clinical target volume identified on the CT scan plus a margin of 1 cm. The procedure was well tolerated; 56% of the patients reported no pain during the procedure, and 46% of the patients developed National Cancer Institute Common Toxicity Criteria Grade 1 acute reaction. None experienced toxicity Grade 2 or 3. Conclusions: Permanent breast seed implantation seems feasible and well tolerated on these preliminary clinical data and represents an ultimate step in the reduction of treatment fraction for partial breast irradiation

  5. Conducting polymer coated neural recording electrodes

    Science.gov (United States)

    Harris, Alexander R.; Morgan, Simeon J.; Chen, Jun; Kapsa, Robert M. I.; Wallace, Gordon G.; Paolini, Antonio G.

    2013-02-01

    Objective. Neural recording electrodes suffer from poor signal to noise ratio, charge density, biostability and biocompatibility. This paper investigates the ability of conducting polymer coated electrodes to record acute neural response in a systematic manner, allowing in depth comparison of electrochemical and electrophysiological response. Approach. Polypyrrole (Ppy) and poly-3,4-ethylenedioxythiophene (PEDOT) doped with sulphate (SO4) or para-toluene sulfonate (pTS) were used to coat iridium neural recording electrodes. Detailed electrochemical and electrophysiological investigations were undertaken to compare the effect of these materials on acute in vivo recording. Main results. A range of charge density and impedance responses were seen with each respectively doped conducting polymer. All coatings produced greater charge density than uncoated electrodes, while PEDOT-pTS, PEDOT-SO4 and Ppy-SO4 possessed lower impedance values at 1 kHz than uncoated electrodes. Charge density increased with PEDOT-pTS thickness and impedance at 1 kHz was reduced with deposition times up to 45 s. Stable electrochemical response after acute implantation inferred biostability of PEDOT-pTS coated electrodes while other electrode materials had variable impedance and/or charge density after implantation indicative of a protein fouling layer forming on the electrode surface. Recording of neural response to white noise bursts after implantation of conducting polymer-coated electrodes into a rat model inferior colliculus showed a general decrease in background noise and increase in signal to noise ratio and spike count with reduced impedance at 1 kHz, regardless of the specific electrode coating, compared to uncoated electrodes. A 45 s PEDOT-pTS deposition time yielded the highest signal to noise ratio and spike count. Significance. A method for comparing recording electrode materials has been demonstrated with doped conducting polymers. PEDOT-pTS showed remarkable low fouling during

  6. Impact of pre-implant lower urinary tract symptoms on postoperative urinary morbidity after permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Teishima, Jun; Iwamoto, Hideo; Miyamoto, Katsutoshi; Shoji, Koichi; Masumoto, Hiroshi; Inoue, Shogo; Kobayashi, Kanao; Kajiwara, Mitsuru; Matsubara, Akio

    2012-01-01

    prolongation. The present findings suggest that the presence of lower urinary tract symptoms before implantation does not prolong urinary morbidity after permanent prostate brachytherapy. (author)

  7. The role of eABR with intracochlear test electrode in decision making between cochlear and brainstem implants: preliminary results.

    Science.gov (United States)

    Cinar, Betul Cicek; Yarali, Mehmet; Atay, Gamze; Bajin, Munir Demir; Sennaroglu, Gonca; Sennaroglu, Levent

    2017-09-01

    The objective of the study was to discuss the findings of intraoperative electrically evoked auditory brainstem response (eABR) test results with a recently designed intracochlear test electrode (ITE) in terms of their relation to decisions of cochlear or auditory brainstem implantation. This clinical study was conducted in Hacettepe University, Department of Otolaryngology, Head and Neck Surgery and Department of Audiology. Subjects were selected from inner ear malformation (IEM) database. Eleven subjects with profound sensorineural hearing loss were included in the current study with age range from 1 year 3 months to 4 years 3 months for children with prelingual hearing loss. There was only one 42-year-old post-lingual subject. eABR was recorded with an ITE and intraoperatively with an original cochlear implant (CI) electrode in 11 cases with different IEMs. Findings of eABR with ITE and their relation to the decision for CI or auditory brainstem implant (ABI) are discussed. Positive eABR test results were found to be dependent on close to normal cochlear structures and auditory nerve. The probability of positive result decreases with increasing degree of malformation severity. The prediction value of eABR via ITE on decision for hearing restoration was found to be questionable in this study. The results of eABR with ITE have predictive value on what we will get with the actual CI electrode. ITE appears to stimulate the cochlea like an actual CI. If the eABR is positive, the results are reliable. However, if eABR is negative, the results should be evaluated with preoperative audiological testing and MRI findings.

  8. Image fusion techniques in permanent seed implantation

    Directory of Open Access Journals (Sweden)

    Alfredo Polo

    2010-10-01

    image fusion for permanent seed implantation.

  9. Suitability of the Binaural Interaction Component for Interaural Electrode Pairing of Bilateral Cochlear Implants.

    Science.gov (United States)

    Hu, Hongmei; Kollmeier, Birger; Dietz, Mathias

    2016-01-01

    Although bilateral cochlear implants (BiCIs) have succeeded in improving the spatial hearing performance of bilateral CI users, the overall performance is still not comparable with normal hearing listeners. Limited success can be partially caused by an interaural mismatch of the place-of-stimulation in each cochlea. Pairing matched interaural CI electrodes and stimulating them with the same frequency band is expected to facilitate binaural functions such as binaural fusion, localization, or spatial release from masking. It has been shown in animal experiments that the magnitude of the binaural interaction component (BIC) derived from the wave-eV decreases for increasing interaural place of stimulation mismatch. This motivated the investigation of the suitability of an electroencephalography-based objective electrode-frequency fitting procedure based on the BIC for BiCI users. A 61 channel monaural and binaural electrically evoked auditory brainstem response (eABR) recording was performed in 7 MED-EL BiCI subjects so far. These BiCI subjects were directly stimulated at 60% dynamic range with 19.9 pulses per second via a research platform provided by the University of Innsbruck (RIB II). The BIC was derived for several interaural electrode pairs by subtracting the response from binaural stimulation from their summed monaural responses. The BIC based pairing results are compared with two psychoacoustic pairing methods: interaural pulse time difference sensitivity and interaural pitch matching. The results for all three methods analyzed as a function of probe electrode allow for determining a matched pair in more than half of the subjects, with a typical accuracy of ± 1 electrode. This includes evidence for statistically significant tuning of the BIC as a function of probe electrode in human subjects. However, results across the three conditions were sometimes not consistent. These discrepancies will be discussed in the light of pitch plasticity versus less plastic

  10. Infective endocarditis and risk of death after cardiac implantable electronic device implantation

    DEFF Research Database (Denmark)

    Özcan, Cengiz; Raunsø, Jakob; Lamberts, Morten

    2017-01-01

    AIMS: To determine the incidence, risk factors, and mortality of infective endocarditis (IE) following implantation of a first-time, permanent, cardiac implantable electronic device (CIED). METHODS AND RESULTS: From Danish nationwide administrative registers (beginning in 1996), we identified all...

  11. Polymer Coatings of Cochlear Implant Electrode Surface - An Option for Improving Electrode-Nerve-Interface by Blocking Fibroblast Overgrowth.

    Directory of Open Access Journals (Sweden)

    C Hadler

    Full Text Available Overgrowth of connective tissue and scar formation induced by the electrode array insertion increase the impedance and, thus, diminish the interactions between neural probes as like cochlear implants (CI and the target tissue. Therefore, it is of great clinical interest to modify the carrier material of the electrodes to improve the electrode nerve interface for selective cell adhesion. On one side connective tissue growth needs to be reduced to avoid electrode array encapsulation, on the other side the carrier material should not compromise the interaction with neuronal cells. The present in vitro-study qualitatively and quantitatively characterises the interaction of fibroblasts, glial cells and spiral ganglion neurons (SGN with ultrathin poly(N,N-dimethylacrylamide (PDMAA, poly(2-ethyloxazoline (PEtOx and poly([2-methacryloyloxyethyl]trimethylammoniumchlorid (PMTA films immobilised onto glass surfaces using a photoreactive anchor layer. The layer thickness and hydrophilicity of the polymer films were characterised by ellipsometric and water contact angle measurement. Moreover the topography of the surfaces was investigated using atomic force microscopy (AFM. The neuronal and non-neuronal cells were dissociated from spiral ganglions of postnatal rats and cultivated for 48 h on top of the polymer coatings. Immunocytochemical staining of neuronal and intermediary filaments revealed that glial cells predominantly attached on PMTA films, but not on PDMAA and PEtOx monolayers. Hereby, strong survival rates and neurite outgrowth were only found on PMTA, whereas PDMAA and PEtOx coatings significantly reduced the SG neuron survival and neuritogenesis. As also shown by scanning electron microscopy (SEM SGN strongly survived and retained their differentiated phenotype only on PMTA. In conclusion, survival and neuritogenesis of SGN may be associated with the extent of the glial cell growth. Since PMTA was the only of the polar polymers used in this study

  12. Conduction Abnormalities and Pacemaker Implantations After SAPIEN 3 Vs SAPIEN XT Prosthesis Aortic Valve Implantation.

    Science.gov (United States)

    Husser, Oliver; Kessler, Thorsten; Burgdorf, Christof; Templin, Christian; Pellegrini, Costanza; Schneider, Simon; Kasel, Albert Markus; Kastrati, Adnan; Schunkert, Heribert; Hengstenberg, Christian

    2016-02-01

    Transcatheter aortic valve implantation is increasingly used in patients with aortic stenosis. Post-procedural intraventricular conduction abnormalities and permanent pacemaker implantations remain a serious concern. Recently, the Edwards SAPIEN 3 prosthesis has replaced the SAPIEN XT. We sought to determine the incidences of new-onset intraventricular conduction abnormalities and permanent pacemaker implantations by comparing the 2 devices. We analyzed the last consecutive 103 patients undergoing transcatheter aortic valve implantation with SAPIEN XT before SAPIEN 3 was used in the next 105 patients. To analyze permanent pacemaker implantations and new-onset intraventricular conduction abnormalities, patients with these conditions at baseline were excluded. Electrocardiograms were recorded at baseline, after the procedure, and before discharge. SAPIEN 3 was associated with higher device success (100% vs 92%; P=.005) and less paravalvular leakage (0% vs 7%; Ppacemaker implantations was 12.6% (23 of 183) with no difference between the 2 groups (SAPIEN 3: 12.5% [12 of 96] vs SAPIEN XT: 12.6% [11 of 87]; P=.99). SAPIEN 3 was associated with a higher rate of new-onset intraventricular conduction abnormalities (49% vs 27%; P=.007) due to a higher rate of fascicular blocks (17% vs 5%; P=.021). There was no statistically significant difference in transient (29% [20 of 69] vs persistent 19% [12 of 64]; P=.168) left bundle branch blocks (28% [19 of 69] vs 17% [11 of 64]; P=.154) when SAPIEN 3 was compared with SAPIEN XT. We found a trend toward a higher rate of new-onset intraventricular conduction abnormalities with SAPIEN 3 compared with SAPIEN XT, although this did not result in a higher permanent pacemaker implantation rate. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  13. Clinical Profile and Early Complications after Single and Dual Chamber Permanent Pacemaker Implantation at Manmohan Cardiothoracic Vascular and Transplant Centre, Kathmandu, Nepal.

    Science.gov (United States)

    Khanal, J; Poudyal, R R; Devkota, S; Thapa, S; Dhungana, R R

    2015-01-01

    Permanent pacemaker implantation is a minimally invasive surgical procedure in the management of patients with cardiac problems. However, complications during and after implantation are not uncommon. There is lack of evidences in rate of complications with the selection of pacemakers in Nepal. Therefore, this study was performed to compare the frequency of implantation and complication rate between single chamber and dual chamber pacemaker. The present study is based on all consecutive pacemaker implantations in a single centre between April 2014 and May 2015. A total of 116 patients were categorized into two cohorts according to the type of pacemaker implanted- single chamber or dual chamber. All patients had regular 2-weeks follow-up intervals with standardized documentation of all relevant patient data till 6-week after implantation. Data were presented as means ± standard deviation (SD) for continuous variables and as proportions for categorical variables. Comparison of continuous variables between the groups was made with independent Student's t-test. For discrete variables distribution between groups were compared with Chi-square test. The mean age (±SD) of total population at implant was 64.08 (± 15.09) years. Dual chamber units were implanted in 44 (37.93%) of patients, single chamber in 72 (62.06%). Only 14 women (31.81%) received dual chamber compared with 42 women (58.33%) who received single chamber (Chi-square=18, DF=1, P = 0.0084). Complete atrioventricular block was the commonest (56.03%) indication for permanent pacemaker insertion followed by sick sinus syndrome (33.62%), symptomatic high-grade AV block (11.20%). Hypertension (dual chamber 21.55%, single chamber 40.51%) was the most common comorbidity in both cohorts. Complications occurred in 11 (9.48%) patients. More proportion of complication occurred in single chamber group (9 patients, 12.50%) than in dual chamber (2 patients, 4.54%). Complications occurring in dual chamber group include

  14. Fractal Interfaces for Stimulating and Recording Neural Implants

    Science.gov (United States)

    Watterson, William James

    From investigating movement in an insect to deciphering cognition in a human brain to treating Parkinson's disease, hearing loss, or even blindness, electronic implants are an essential tool for understanding the brain and treating neural diseases. Currently, the stimulating and recording resolution of these implants remains low. For instance, they can record all the neuron activity associated with movement in an insect, but are quite far from recording, at an individual neuron resolution, the large volumes of brain tissue associated with cognition. Likewise, there is remarkable success in the cochlear implant restoring hearing due to the relatively simple anatomy of the auditory nerves, but are failing to restore vision to the blind due to poor signal fidelity and transmission in stimulating the more complex anatomy of the visual nerves. The critically important research needed to improve the resolution of these implants is to optimize the neuron-electrode interface. This thesis explores geometrical and material modifications to both stimulating and recording electrodes which can improve the neuron-electrode interface. First, we introduce a fractal electrode geometry which radically improves the restored visual acuity achieved by retinal implants and leads to safe, long-term operation of the implant. Next, we demonstrate excellent neuron survival and neurite outgrowth on carbon nanotube electrodes, thus providing a safe biomaterial which forms a strong connection between the electrode and neurons. Additional preliminary evidence suggests carbon nanotubes patterned into a fractal geometry will provide further benefits in improving the electrode-neuron interface. Finally, we propose a novel implant based off field effect transistor technology which utilizes an interconnecting fractal network of semiconducting carbon nanotubes to record from thousands of neurons simutaneously at an individual neuron resolution. Taken together, these improvements have the potential to

  15. Permanent pacemaker implantation in octogenarians with unexplained syncope and positive electrophysiologic testing.

    Science.gov (United States)

    Giannopoulos, Georgios; Kossyvakis, Charalampos; Panagopoulou, Vasiliki; Tsiachris, Dimitrios; Doudoumis, Konstantinos; Mavri, Maria; Vrachatis, Dimitrios; Letsas, Konstantinos; Efremidis, Michael; Katsivas, Apostolos; Lekakis, John; Deftereos, Spyridon

    2017-05-01

    Syncope is a common problem in the elderly, and a permanent pacemaker is a therapeutic option when a bradycardic etiology is revealed. However, the benefit of pacing when no association of symptoms to bradycardia has been shown is not clear, especially in the elderly. The aim of this study was to evaluate the effect of pacing on syncope-free mortality in patients aged 80 years or older with unexplained syncope and "positive" invasive electrophysiologic testing (EPT). This was an observational study. A positive EPT for the purposes of this study was defined by at least 1 of the following: a corrected sinus node recovery time of >525 ms, a basic HV interval of >55 ms, detection of infra-Hisian block, or appearance of second-degree atrioventricular block on atrial decremental pacing at a paced cycle length of >400 ms. Among the 2435 screened patients, 228 eligible patients were identified, 145 of whom were implanted with a pacemaker. Kaplan-Meier analysis determined that time to event (syncope or death) was 50.1 months (95% confidence interval 45.4-54.8 months) with a pacemaker vs 37.8 months (95% confidence interval 31.3-44.4 months) without a pacemaker (log-rank test, P = .001). The 4-year time-dependent estimate of the rate of syncope was 12% vs 44% (P pacemaker implantation was independently associated with longer syncope-free survival. Significant differences were also shown in the individual components of the primary outcome measure (syncope and death from any cause). Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  16. Terapia de resincronización con implante de electrodo ventricular izquierdo por vía epicárdica Resynchronization therapy with left ventricular electrode implant via epicardium

    Directory of Open Access Journals (Sweden)

    Francisco Gómez

    2007-12-01

    casos. No se presentaron complicaciones durante el procedimiento ni estimulación diafragmática o desalojo del eléctrodo epicárdico después de seis meses de seguimiento. Conclusión: se demostró que la implantación de marcapasos tricameral para resincronización cardiaca con la utilización de electrodo epicárdico ventricular izquierdo, es una terapia segura, con la cual se obtienen parámetros adecuados de implantación y normofunción del dispositivo.Introduction: heart resynchronization therapy is safe and effective for improving functional class and quality of life and to diminish mortality in patients with heart failure in functional state III and IV with optimal medical therapy. Methods: we report the procedure realized to a group of patients in the Cardiovascular and Transplant Unit at the University Hospital San Vicente de Paul and the Antioquia University between November 2004 and February 2006, to whom a tricameral pacemaker for cardiac resynchronization was implanted, inserting the left ventricular electrode via epicardium. Patients chosen for the insertion fulfilled the heart failure state C or D criteria, according to the NYHA III or IV classification, corroborated with functional test 120ms. and echocardiographic criteria of intra-ventricular, inter-ventricular or atrio-ventricular dyssynchronism. Results: 9 patients were included: 5 men and 4 women with mean age 57 years; 8 patients had left His bundle block. The implant procedure was realized in two times: the first one in the hemodynamics ward where an electrode in right atrium and right ventricle was put, and the second one in the operating room where an electrode in the left ventricle via epicardium through left anterior mini-thoracotomy was implanted. Total procedure time oscillated between 35 and 210 minutes with a mean of 105 minutes, and less than this in the last patients. Intra-operative measures show a mean stimulation threshold of 0.9 mV; QRST duration was less than 130 ms. after

  17. High-current and low acceleration voltage arsenic ion implanted polysilicon-gate and source-drain electrode Si mos transistor

    International Nuclear Information System (INIS)

    Saito, Yasuyuki; Sugimura, Yoshiro; Sugihara, Michiyuki

    1993-01-01

    The fabrication process of high current arsenic (As) ion implanted polysilicon (Si) gate and source drain (SD) electrode Si n-channel metal oxide-semiconductor field effect transistor (MOSFET) was examined. Poly Si film n-type doping was performed by using high current (typical current: 2mA) and relatively low acceleration voltage (40keV) As ion implantation technique (Lintott series 3). It was observed that high dose As implanted poly Si films as is show refractoriness against radical fluorine excited by microwave. Using GCA MANN4800 (m/c ID No.2, resist: OFPR) mask pattern printing technique, the high current As ion implantation technique and radical fluorine gas phase etching (Chemical dry etching: CDE) technique, the n-channel Poly Si gate (ρs = ≅100Ω/□) enhancement MQSFETs(ρs source drain = ≅50Ω/□, SiO 2 gate=380 angstrom) with off-leak-less were obtained on 3 inch Czochralski grown 2Ωcm boron doped p type wafers (Osaka titanium). By the same process, a 8 bit single chip μ-processor with 26MHz full operation was performed

  18. Expansão rápida da maxila ancorada em implantes: uma nova proposta para expansão ortopédica na dentadura permanente Rapid maxillary expansion anchored by implants: a new proposal to orthopedic expansion in the permanent dentition

    Directory of Open Access Journals (Sweden)

    Daniela Gamba Garib

    2007-06-01

    Full Text Available OBJETIVO: este trabalho apresenta um método para expansão ortopédica da maxila, na dentadura permanente, utilizando implantes como ancoragem. METODOLOGIA: detalharam-se os procedimentos cirúrgicos e laboratoriais da confecção de um expansor com ancoragem dento-óssea em crânio seco humano. Dois implantes de titânio foram colocados na região anterior do palato, e o parafuso Hyrax adaptado de modo que a expansão ancorou-se nos implantes e nos primeiros molares permanentes. RESULTADOS: o experimento laboratorial em crânio seco mostrou que o procedimento apresenta-se anatômica e operacionalmente viável. Os implantes suportaram a força gerada pela ativação do parafuso expansor, redundando na separação transversal das hemimaxilas. CONCLUSÕES: vislumbra-se que a expansão rápida da maxila ancorada em implantes (ERMAI poderá potencializar a eficiência da expansão ortopédica, assim como reduzir o custo periodontal dos procedimentos convencionais de expansão. Futuros estudos clínicos são necessários para testar essas hipóteses.AIM: This study presents a method for maxillary orthopedic expansion, in the permanent dentition, using implants as anchorage. METHODS: Surgical and laboratorial procedures for the construction of a tooth-bone-borne expansor was detailed in a human dry skull. Two titanium implants were placed in the anterior region of the palate and a Hyrax screw was adapted in a way that the expansion was anchored both on the palatal implants and on permanent first molars. RESULTS: The laboratorial experiment in dry skull showed that the procedure is operationally and anatomically possible. The implants supported the force generated by the expansion screw activation and the maxilla halves were transversally split. CONCLUSIONS: Rapid maxillary expansion anchored on implants can increase the efficiency of orthopedic expansion and decrease the periodontal sequela caused by conventional RME. Further clinical studies are

  19. A Wireless and Batteryless Microsystem with Implantable Grid Electrode/3-Dimensional Probe Array for ECoG and Extracellular Neural Recording in Rats

    Directory of Open Access Journals (Sweden)

    Chih-Wei Chang

    2013-04-01

    Full Text Available This paper presents the design and implementation of an integrated wireless microsystem platform that provides the possibility to support versatile implantable neural sensing devices in free laboratory rats. Inductive coupled coils with low dropout regulator design allows true long-term recording without limitation of battery capacity. A 16-channel analog front end chip located on the headstage is designed for high channel account neural signal conditioning with low current consumption and noise. Two types of implantable electrodes including grid electrode and 3D probe array are also presented for brain surface recording and 3D biopotential acquisition in the implanted target volume of tissue. The overall system consumes less than 20 mA with small form factor, 3.9 × 3.9 cm2 mainboard and 1.8 × 3.4 cm2 headstage, is packaged into a backpack for rats. Practical in vivo recordings including auditory response, brain resection tissue and PZT-induced seizures recording demonstrate the correct function of the proposed microsystem. Presented achievements addressed the aforementioned properties by combining MEMS neural sensors, low-power circuit designs and commercial chips into system-level integration.

  20. Embedded Ultrathin Cluster Electrodes for Long-Term Recordings in Deep Brain Centers.

    Directory of Open Access Journals (Sweden)

    Leila Etemadi

    Full Text Available Neural interfaces which allow long-term recordings in deep brain structures in awake freely moving animals have the potential of becoming highly valuable tools in neuroscience. However, the recording quality usually deteriorates over time, probably at least partly due to tissue reactions caused by injuries during implantation, and subsequently micro-forces due to a lack of mechanical compliance between the tissue and neural interface. To address this challenge, we developed a gelatin embedded neural interface comprising highly flexible electrodes and evaluated its long term recording properties. Bundles of ultrathin parylene C coated platinum electrodes (N = 29 were embedded in a hard gelatin based matrix shaped like a needle, and coated with Kollicoat™ to retard dissolution of gelatin during the implantation. The implantation parameters were established in an in vitro model of the brain (0.5% agarose. Following a craniotomy in the anesthetized rat, the gelatin embedded electrodes were stereotactically inserted to a pre-target position, and after gelatin dissolution the electrodes were further advanced and spread out in the area of the subthalamic nucleus (STN. The performance of the implanted electrodes was evaluated under anesthesia, during 8 weeks. Apart from an increase in the median-noise level during the first 4 weeks, the electrode impedance and signal-to-noise ratio of single-units remained stable throughout the experiment. Histological postmortem analysis confirmed implantation in the area of STN in most animals. In conclusion, by combining novel biocompatible implantation techniques and ultra-flexible electrodes, long-term neuronal recordings from deep brain structures with no significant deterioration of electrode function were achieved.

  1. Implant experience with an implantable hemodynamic monitor for the management of symptomatic heart failure.

    Science.gov (United States)

    Steinhaus, David; Reynolds, Dwight W; Gadler, Fredrik; Kay, G Neal; Hess, Mike F; Bennett, Tom

    2005-08-01

    Management of congestive heart failure is a serious public health problem. The use of implantable hemodynamic monitors (IHMs) may assist in this management by providing continuous ambulatory filling pressure status for optimal volume management. The Chronicle system includes an implanted monitor, a pressure sensor lead with passive fixation, an external pressure reference (EPR), and data retrieval and viewing components. The tip of the lead is placed near the right ventricular outflow tract to minimize risk of sensor tissue encapsulation. Implant technique and lead placement is similar to that of a permanent pacemaker. After the system had been successfully implanted in 148 patients, the type and frequency of implant-related adverse events were similar to a single-chamber pacemaker implant. R-wave amplitude was 15.2 +/- 6.7 mV and the pressure waveform signal was acceptable in all but two patients in whom presence of artifacts required lead repositioning. Implant procedure time was not influenced by experience, remaining constant throughout the study. Based on this evaluation, permanent placement of an IHM in symptomatic heart failure patients is technically feasible. Further investigation is warranted to evaluate the use of the continuous hemodynamic data in management of heart failure patients.

  2. The main features of electrical stimulation of biological tissues by implant electrodes: study from engineering perspective and equipment development to produce

    International Nuclear Information System (INIS)

    Suarez Bagnasco, D.; Alvarez Alonso, J.; Suarez Antola, R.

    2004-08-01

    The main features of electrical stimulation of biological tissues by implant electrodes are studied.These electrodes are applied in neural prostheses and cardiac pacing.Threshold phenomena are stressed and some aspects related with implant electrode design are discussed. A fairly through theoretical research about the optimal pulse shape for electrical stimulation of biological tissues is done.The excitation functional is introduced as a criterium to identify threshold pulses of electric current. We obtain the optimal pulse shapes that minimize the energy dissipated in tissues, or the energy taken by the load seen by the pulse generator, amongst other criteria.We show how these pulse shapes can be determined from experimentally measured strength-duration (S-D) curves using rectangular pulses of current. The development of a prototype of a new equipment is described.The equipment may be used to measure S-D curves and with this information it is able to syntetize the abovementioned optimal pulse shapes. The top-down design process is presented, involving both hardware and software.The construction and assembling of the prototype, as well as the implementation of software are described.Some testing and measures with the prototype, including test with biological tissues are described and assessed

  3. Pneumococcal meningitis post-cochlear implantation: preventative measures.

    Science.gov (United States)

    Wei, Benjamin P C; Shepherd, Robert K; Robins-Browne, Roy M; Clark, Graeme M; O'Leary, Stephen J

    2010-11-01

    Both clinical data and laboratory studies demonstrated the risk of pneumococcal meningitis post-cochlear implantation. This review examines strategies to prevent post-implant meningitis. Medline/PubMed database; English articles after 1980. Search terms: cochlear implants, pneumococcus meningitis, streptococcus pneumonia, immunization, prevention. Narrative review. All articles relating to post-implant meningitis without any restriction in study designs were assessed and information extracted. The presence of inner ear trauma as a result of surgical technique or cochlear implant electrode array design was associated with a higher risk of post-implant meningitis. Laboratory data demonstrated the effectiveness of pneumococcal vaccination in preventing meningitis induced via the hematogenous route of infection. Fibrous sealing around the electrode array at the cochleostomy site, and the use of antibiotic-coated electrode array reduced the risk of meningitis induced via an otogenic route. The recent scientific data support the U.S. Food and Drug Administration recommendation of pneumococcal vaccination for the prevention of meningitis in implant recipients. Nontraumatic cochlear implant design, surgical technique, and an adequate fibrous seal around the cochleostomy site further reduce the risk of meningitis. Copyright © 2010 American Academy of Otolaryngology–Head and Neck Surgery Foundation. Published by Mosby, Inc. All rights reserved.

  4. Three-dimensional verification of 125I seed stability after permanent implantation in the parotid gland and periparotid region

    International Nuclear Information System (INIS)

    Fan, Yi; Huang, Ming-Wei; Zheng, Lei; Zhao, Yi-Jiao; Zhang, Jian-Guo

    2015-01-01

    To evaluate seed stability after permanent implantation in the parotid gland and periparotid region via a three-dimensional reconstruction of CT data. Fifteen patients treated from June 2008 to June 2012 at Peking University School and Hospital of Stomatology for parotid gland tumors with postoperative adjunctive 125 I interstitial brachytherapy were retrospectively reviewed in this study. Serial CT data were obtained during follow-up. Mimics and Geomagic Studio software were used for seed reconstruction and stability analysis, respectively. Seed loss and/or migration outside of the treated area were absent in all patients during follow-up (23–71 months). Total seed cluster volume was maximized on day 1 post-implantation due to edema and decreased significantly by an average of 13.5 % (SD = 9.80 %; 95 % CI, 6.82–17.68 %) during the first two months and an average of 4.5 % (SD = 3.60 %; 95 % CI, 2.29–6.29 %) during the next four months. Volume stabilized over the subsequent six months. 125 I seed number and location were stable with a general volumetric shrinkage tendency in the parotid gland and periparotid region. Three-dimensional seed reconstruction of CT images is feasible for visualization and verification of implanted seeds in parotid brachytherapy

  5. Bipolar leads for use with permanently implantable cardiac pacing systems: a review of limitations of traditional and coaxial configurations and the development and testing of new conductor, insulation, and electrode designs.

    Science.gov (United States)

    Tyers, G F; Mills, P; Clark, J; Cheesman, M; Yeung-Lai-Wah, J A; Brownlee, R R

    1997-01-01

    The unacceptable rate of mechanical failures, threshold problems, and recalls experienced with many coaxial bipolar cardiac pacing lead designs are reviewed in detail. To address these problems, redundant insulation coradial atrial and ventricular tined leads (AL and VL, respectively) with iridium oxide electrodes were developed and subjected to extensive accelerated testing. There were no mechanical failures. The new lead body design proved to be much more durable than widely used trifilar MP35N configurations. The data reviewed and early and current test results are strongly supportive of tightly coupled insulation being a major factor in improving lead durability as long as the insulating material is not stressed. In addition to improving flex life, insulation adherence to the conductor may reduce the potential for ionic degradation. Pacing and sensing thresholds in animal studies of the new leads were within the reported range for leads with steroid eluting electrodes. A multicenter Canadian clinical trial was initiated with the first implant in early January 1994. By November 1995, 110 VL and 82 AL had been placed in 124 patients and followed for a mean of 11 +/- 6 months; maximum 21, total 1355. There were 60 males and 64 females with a mean age of 64 +/- 16 years, range 15-88. Primary indications for pacing were AV block in 61 patients, sick sinus syndrome in 53, vasovagal syncope in 4, and congestive heart failure in 7. Many patients had associated or primary tachyarrhythmias, including 111 with supraventricular and 12 with ventricular. Forty-two percent of patients (52/124) had prior cardiac procedures, including 18 open heart surgeries and 20 AV nodal ablations. At implant, 8 lead characteristics were rated good or excellent in 90% (746/829) of evaluations. X-ray visibility was of concern in 10% of patients (12/124). Three perioperative complications occurred, including displacement of one AL (1.2%) and one VL (0.9%). There were no subsequent mechanical

  6. Multichannel cochlear implantation in the scala vestibuli.

    Science.gov (United States)

    Lin, Karen; Marrinan, Michelle S; Waltzman, Susan B; Roland, J Thomas

    2006-08-01

    Sensorineural hearing loss resulting from otosclerosis, meningitis, chronic otitis media, autoimmune ear disease, and trauma can be associated with partial or total obstruction of the cochlear scalae. Multichannel cochlear implantation may be difficult in a cochlea with an obstructed scala tympani. The purpose of this study is to determine the safety and efficacy of scala tympani electrode insertion. Retrospective chart review. Academic medical center. Eight children and adults with profound sensorineural hearing loss who underwent cochlear implantation with known scala vestibuli electrode array insertion were subjects for this study. Eight study subjects underwent implantation: five with the Nucleus 24RCS (Contour) device and three with the Nucleus 24M device. Imaging findings, operative findings, and age-appropriate speech perception testing. All patients had full electrode insertion. Various obstructive patterns on computed tomography and magnetic resonance imaging were found, and there was a range of speech perception results. All but one patient improved based on age-appropriate monosyllabic word and sentence tests. Scala vestibuli multielectrode insertion is a viable alternative when scala tympani insertion is not possible because of abnormal anatomy or anatomical changes secondary to disease or previous implantation. We will also present an algorithm of options for decision making for implantation when encountering cochlear obstruction and difficult electrode insertion.

  7. Poly(3,4-ethylenedioxythiophene) (PEDOT) polymer coatings facilitate smaller neural recording electrodes

    Science.gov (United States)

    Ludwig, Kip A.; Langhals, Nicholas B.; Joseph, Mike D.; Richardson-Burns, Sarah M.; Hendricks, Jeffrey L.; Kipke, Daryl R.

    2011-02-01

    We investigated using poly(3,4-ethylenedioxythiophene) (PEDOT) to lower the impedance of small, gold recording electrodes with initial impedances outside of the effective recording range. Smaller electrode sites enable more densely packed arrays, increasing the number of input and output channels to and from the brain. Moreover, smaller electrode sizes promote smaller probe designs; decreasing the dimensions of the implanted probe has been demonstrated to decrease the inherent immune response, a known contributor to the failure of long-term implants. As expected, chronically implanted control electrodes were unable to record well-isolated unit activity, primarily as a result of a dramatically increased noise floor. Conversely, electrodes coated with PEDOT consistently recorded high-quality neural activity, and exhibited a much lower noise floor than controls. These results demonstrate that PEDOT coatings enable electrode designs 15 µm in diameter.

  8. Treatment of prostate adenocarcinoma permanent implants with I 125: first experience in Uruguay; Tratamiento del adenocarcinoma de prostata con implantes permanentes de I125: primera experiencia en el Uruguay

    Energy Technology Data Exchange (ETDEWEB)

    Quarneti, A.; Clark, O.; Glaussius, A.; Kaitasoff, P.; Cosia, G.

    2010-12-15

    Full text: Objective: To report on the treatment done, toxicity and development of a group of adenocarcinoma patients with localized prostate brachytherapy implants permanent I125. Material and Methods. 37 patients were treated in the period 2001 to 2004 at the Military Hospital Central by this treatment modality. All of them were performed before implantation planning, which consisted of the volumetric calculation and calculation prostate dosimetry that included transrectal prostate ultrasound 3-5 weeks before the procedure. all patients had pathological confirmation of the lesion showed PSA values less than 11 ng / ml and Gleason score less than 7. 70% of patients received neo-adjuvant hormone therapy. In 5 patients an interactive planning system was performed computerized dosimetry, using sequential ultrasound imaging planes, allowed the dosimetric analysis before terminate the procedure and make necessary adjustments if the dose distribution did not conform. This additional dosimetric study we have not been described by other authors. Prescribed in the first 10 patients was dose 144 Gy and 160 Gy in subsequent. All patients underwent post implant CT waffle grid after 15 days of the procedure. analyzed the dose volume histogram (HDV) and D90 values??. Clinical follow-up was performed and PSA biochemical .. Preliminary Results: 33 patients were in local control without biochemical failure. Currently 4 patients presented biochemical recurrence with PSA values ??between 4 and 6 ng / ml. In neither disease was found at a distance and then raises confirmation tumor biopsy active presence will undergo surgical treatment protocols localized prostate cancer. HDV values ??D90 and are consistent with the informed by the international literature will be presented. No patient required hospitalization prolonged (greater than 24 hours) or use of higher analgesics. 2 patients had acute urinary retention (G II complication) between the tenth and twentieth day, the rest of the

  9. Technique eliminates high voltage arcing at electrode-insulator contact area

    Science.gov (United States)

    Mealy, G.

    1967-01-01

    Coating the electrode-insulator contact area with silver epoxy conductive paint and forcing the electrode and insulator tightly together into a permanent connection, eliminates electrical arcing in high-voltage electrodes supplying electrical power to vacuum facilities.

  10. The scala vestibuli for cochlear implantation. An anatomic study.

    Science.gov (United States)

    Gulya, A J; Steenerson, R L

    1996-02-01

    Traditionally, cochlear implantation has used the scala tympani (ST) for electrode insertion. When faced with ST ossification, the surgeon may elect to drill out the cochlea to accomplish partial electrode insertion. Theoretically, another option in this situation is to insert the electrode into the scala vestibuli (SV). To determine whether or not the dimensions of the SV are sufficient to accommodate an electrode array so as to assess the feasibility of SV cochlear implantation. The study of 20 normal human temporal bones, comparing the maximum diameter and surface area of the ST with those of the combined SV and scala media. The dimensions of the SV and scala media were comparable to those of the ST and appeared sufficient to accommodate a cochlear implant electrode array. It appears that the combination of SV and scala media is a viable alternative route for electrode insertion, at least on the basis of anatomic dimensions, in those cases in which the ST is obliterated.

  11. Electromagnetic interference of mobile phones with electronic implants

    International Nuclear Information System (INIS)

    Kainz, W.

    2000-03-01

    Chapter 1:Interference matrix: The objective of Chapter 1 was to give an overview of the implants used at present and their electromagnetic compatibility (EMC). The evaluation of the available literature provides an estimate of the probability of electronic implants being influenced by various interference sources. A literature search at the AKH (Allgemeines Krankenhaus) in Vienna and at the Technical University of Vienna in the FIZ (Fach-Informations-Zentrum) -Biomedizinische Technik, Medline, Pascal Biomed, CC Search und Embase databases yielded 236 relevant publications. At present 12 different implants are used: pacemaker, defibrillator, cochlear and brain-stem implants, neurostimulators, spinal-cord stimulators, spinal-fusion stimulators, telemetry systems, artificial hearts, drug-delivery systems, neurological pulse generators, visual prosthetics and implantable patient chips. The frequency with which they are used and the EMC on exposure to the various interference sources was summarized. Publications on EMC were found only for the first six implant types and only for 30% of the possible combinations of implant type and interference source. Based on the number of the implants examined, the probability of interference was calculated and summarized in the interference matrix. Chapter 2:Measurements on the phantom: No publication on the electromagnetic compatibility of neurological pulse generators (NPG) could be found. This implant has been used increasingly in the last few years to treat Parkinson's disease. A phantom was built to examine this implant at 900 MHz. The electromagnetic compatibility was measured by exposing the NPG to the fields of ten different 900 MHz GSM mobile phones. Every mobile phone was tested in three different positions relative to the phantom, with four electrode configurations and four stimulation parameters. No interference was found even at a maximum transmit power of 2 watts. Further tests with half-wave dipoles and increased

  12. Effect of permanent pacemaker on mortality after transcatheter aortic valve replacement

    DEFF Research Database (Denmark)

    Engborg, Jonathan; Riechel-Sarup, Casper; Gerke, Oke

    2017-01-01

    OBJECTIVES: Transcatheter aortic valve implantation (TAVI) is an established treatment for high-grade aortic valve stenosis in patients found unfit for open heart surgery. The method may cause cardiac conduction disorders requiring permanent pacemaker (PPM) implantation, and the long-term effect...

  13. Challenges in Improving Cochlear Implant Performance and Accessibility.

    Science.gov (United States)

    Zeng, Fan-Gang

    2017-08-01

    Here I identify two gaps in cochlear implants that have been limiting their performance and acceptance. First, cochlear implant performance has remained largely unchanged, despite the number of publications tripling per decade in the last 30 years. Little has been done so far to address a fundamental limitation in the electrode-to-neuron interface, with the electrode size being a thousand times larger than the neuron diameter while the number of electrodes being a thousand times less. Both the small number and the large size of electrodes produce broad spatial activation and poor frequency resolution that limit current cochlear implant performance. Second, a similarly rapid growth in cochlear implant volume has not produced an expected decrease in unit price in the same period. The high cost contributes to low market penetration rate, which is about 20% in developed countries and less than 1% in developing countries. I will discuss changes needed in both research strategy and business practice to close the gap between prosthetic and normal hearing as well as that between haves and have-nots.

  14. 76 FR 53851 - Effective Date of Requirement for Premarket Approval for Cardiovascular Permanent Pacemaker...

    Science.gov (United States)

    2011-08-30

    ... Pacemaker Electrode; Correction AGENCY: Food and Drug Administration, HHS. ACTION: Proposed rule; correction... preamendments device: Cardiovascular permanent pacemaker electrode. The document was published with an incorrect...

  15. Modeling of Auditory Neuron Response Thresholds with Cochlear Implants

    Directory of Open Access Journals (Sweden)

    Frederic Venail

    2015-01-01

    Full Text Available The quality of the prosthetic-neural interface is a critical point for cochlear implant efficiency. It depends not only on technical and anatomical factors such as electrode position into the cochlea (depth and scalar placement, electrode impedance, and distance between the electrode and the stimulated auditory neurons, but also on the number of functional auditory neurons. The efficiency of electrical stimulation can be assessed by the measurement of e-CAP in cochlear implant users. In the present study, we modeled the activation of auditory neurons in cochlear implant recipients (nucleus device. The electrical response, measured using auto-NRT (neural responses telemetry algorithm, has been analyzed using multivariate regression with cubic splines in order to take into account the variations of insertion depth of electrodes amongst subjects as well as the other technical and anatomical factors listed above. NRT thresholds depend on the electrode squared impedance (β = −0.11 ± 0.02, P<0.01, the scalar placement of the electrodes (β = −8.50 ± 1.97, P<0.01, and the depth of insertion calculated as the characteristic frequency of auditory neurons (CNF. Distribution of NRT residues according to CNF could provide a proxy of auditory neurons functioning in implanted cochleas.

  16. SU-E-T-12: A Comparative Dosimetric Study of Pre and Post Prostate Iodine-125 Permanent Seed Implants

    Energy Technology Data Exchange (ETDEWEB)

    Liu, X; Rahimian, J; Goy, B; Cosmatos, H; Qian, Y [Kaiser Permanente, Los Angeles, CA (United States)

    2015-06-15

    Purpose: Post-implant dosimetry has become the gold standard for prostate implant evaluation. The goal of this research is to compare the dosimetry between pre-plan and post-plan in permanent prostate seed implant brachytherapy. Methods: A retrospective study of 91 patients treated with Iodine-125 prostate seed implant between year 2012∼2014 were performed. All plans were created using a VariSeed 8.0 planning system. Pre-plan ultrasound images were acquired using 0.5 cm slice thickness. Post-plan CT images acquired about 1–4 weeks after implant, fused with the preplan ultrasound images. The prostate and urethra contours were generated using the fusion of ultrasound and CT images. Iodine-125 seed source activities varied between 0.382 to 0.414 mCi per seed. The loading patterns varied slightly between patients depending on the prostate size. Statistical analysis of pre and post plans for prostate and urethra volumes, V100%, V150% and D90, and urethra D10 were performed and reported. Results: The pre and post implant average prostate size was 36.90cc vs. 38.58cc; V100% was 98.33% vs. 96.89%; V150% was 47.09% vs. 56.95%; D90 was 116.35Gy vs. 116.12Gy, urethra volume was 1.72cc vs. 1.85cc, urethra D10% was 122.0% vs. 135.35%, respectively. There was no statistically significant difference between the pre and post-plan values for D90(p-value=0.43). However, there are significant differences between other parameters most likely due to post surgical edema; prostate size (p-value= 0.00015); V100% (p-value=3.7803E-07); V150% (p-value=1.49E-09); urethra volume (p-value= 2.77E-06); Urethra D10 (p-value=7.37E-11). Conclusion: The post-plan dosimetry using CT image set showed similar D90 dose coverage to the pre-plan using the ultrasound image dataset. The study showed that our prostate seed implants have consistently delivered adequate therapeutic dose to the prostate while sparing urethra. Future studies to correlate dose versus biochemical response using patients’ PSA

  17. Report on the Clinical Outcomes of Permanent Breast Seed Implant for Early-Stage Breast Cancers

    International Nuclear Information System (INIS)

    Pignol, Jean-Philippe; Caudrelier, Jean-Michel; Crook, Juanita; McCann, Claire; Truong, Pauline; Verkooijen, Helena A.

    2015-01-01

    Purpose: Permanent breast seed implant is an accelerated partial breast irradiation technique realizing the insertion of "1"0"3Pd seeds in the seroma after lumpectomy. We report the 5-year efficacy and tolerance for a cohort, pooling patients from 3 clinical trials. Methods and Materials: The trials accrued postmenopausal patients with infiltrating ductal carcinoma or ductal carcinoma in situ ≤3 cm and clear surgical margins, who were node negative, and had a planning target volume <120 cm"3. The outcomes included overall and disease-free survival and local and contralateral recurrence at 5 years. The true local recurrence rate was compared using 2-tailed paired t tests for estimates calculated using the Tufts University ipsilateral breast tumor recurrence and Memorial Sloan Kettering ductal carcinoma in situ nomograms. Results: The cohort included 134 patients, and the observed local recurrence rate at a median follow-up period of 63 months was 1.2% ± 1.2%, similar to the estimate for whole breast irradiation (P=.23), significantly better than for surgery alone (relative risk 0.27; P<.001), and significantly lower than contralateral recurrence (relative risk 0.33; P<.001). The 5-year overall survival rate was 97.4% ± 1.9%, and the disease-free survival rate was 96.4% ± 2.1%. At 2 months, 42% of the patients had erythema, 20% induration, and 16% moist desquamation. The rate of mainly grade 1 telangiectasia was 22.4% at 2 years and 24% at 5 years. The rate of asymptomatic induration was 23% at 2 years and 40% at 5 years. Conclusions: The 5-year data suggest that permanent breast seed implantation is a safe accelerated partial breast irradiation option after lumpectomy for early-stage breast cancer with a tolerance profile similar to that of whole breast irradiation.

  18. SU-F-BRA-03: Integrating Novel Electromagnetic Tracking Hollow Needle Assistance in Permanent Implant Brachytherapy Procedures

    Energy Technology Data Exchange (ETDEWEB)

    Racine, E; Hautvast, G; Binnekamp, D [Philips Group Innovation - Biomedical Systems, Eindhoven (Netherlands); Beaulieu, L [Centre Hospitalier Univ de Quebec, Quebec, QC (Canada)

    2015-06-15

    Purpose: To report on the results of a complete permanent implant brachytherapy procedure assisted by an electromagnetic (EM) hollow needle possessing both 3D tracking and seed drop detection abilities. Methods: End-to-end in-phantom EM-assisted LDR procedures were conducted. The novel system consisted of an EM tracking apparatus (NDI Aurora V2, Planar Field Generator), a 3D US scanner (Philips CX50), a hollow needle prototype allowing 3D tracking and seed drop detection and a specially designed treatment planning software (Philips Healthcare). A tungsten-doped 30 cc spherical agarose prostate immersed in gelatin was used for the treatment. A cylindrical shape of 0.8 cc was carved along its diameter to mimic the urethra. An initial plan of 26 needles and 47 seeds was established with the system. The plan was delivered with the EM-tracked hollow needle, and individual seed drop locations were recorded on the fly. The phantom was subsequently imaged with a CT scanner from which seed positions and contour definitions were obtained. The DVHs were then independently recomputed and compared with those produced by the planning system, both before and after the treatment. Results: Of the 47 seeds, 45 (96%) were detected by the EM technology embedded in the hollow needle design. The executed plan (from CT analysis) differed from the initial plan by 2%, 14% and 8% respectively in terms of V100, D90 and V150 for the prostate, and by 8%, 7% and 10% respectively in terms of D5, V100 and V120 for the urethra. Conclusion: The average DVH deviations between initial and executed plans were within a 5% tolerance imposed for this proof-of-concept assessment. This relatively good concordance demonstrates the feasibility and potential benefits of combining EM tracking and seed drop detection for real-time dosimetry validation and assistance in permanent implant brachytherapy procedures. This project has been entirely funded by Philips Healthcare.

  19. Report on the Clinical Outcomes of Permanent Breast Seed Implant for Early-Stage Breast Cancers

    Energy Technology Data Exchange (ETDEWEB)

    Pignol, Jean-Philippe, E-mail: j.p.pignol@erasmusmc.nl [Radiation Oncology Department, University of Toronto at Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada); Radiation Oncology Department, Erasmus Medical Center Cancer Institute, Rotterdam (Netherlands); Caudrelier, Jean-Michel [Department of Radiation Medicine, The Ottawa Hospital Cancer Centre, Ottawa, Ontario (Canada); Crook, Juanita [Department of Radiation Oncology, BC Cancer Agency Center for the Southern Interior, Kelowna, British Columbia (Canada); McCann, Claire [Radiation Oncology Department, University of Toronto at Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada); Truong, Pauline [Radiation Oncology Department, BC Cancer Agency Vancouver Island Centre, Victoria, British Columbia (Canada); Verkooijen, Helena A. [Imaging Division, University Medical Centre Utrecht, Utrecht (Netherlands)

    2015-11-01

    Purpose: Permanent breast seed implant is an accelerated partial breast irradiation technique realizing the insertion of {sup 103}Pd seeds in the seroma after lumpectomy. We report the 5-year efficacy and tolerance for a cohort, pooling patients from 3 clinical trials. Methods and Materials: The trials accrued postmenopausal patients with infiltrating ductal carcinoma or ductal carcinoma in situ ≤3 cm and clear surgical margins, who were node negative, and had a planning target volume <120 cm{sup 3}. The outcomes included overall and disease-free survival and local and contralateral recurrence at 5 years. The true local recurrence rate was compared using 2-tailed paired t tests for estimates calculated using the Tufts University ipsilateral breast tumor recurrence and Memorial Sloan Kettering ductal carcinoma in situ nomograms. Results: The cohort included 134 patients, and the observed local recurrence rate at a median follow-up period of 63 months was 1.2% ± 1.2%, similar to the estimate for whole breast irradiation (P=.23), significantly better than for surgery alone (relative risk 0.27; P<.001), and significantly lower than contralateral recurrence (relative risk 0.33; P<.001). The 5-year overall survival rate was 97.4% ± 1.9%, and the disease-free survival rate was 96.4% ± 2.1%. At 2 months, 42% of the patients had erythema, 20% induration, and 16% moist desquamation. The rate of mainly grade 1 telangiectasia was 22.4% at 2 years and 24% at 5 years. The rate of asymptomatic induration was 23% at 2 years and 40% at 5 years. Conclusions: The 5-year data suggest that permanent breast seed implantation is a safe accelerated partial breast irradiation option after lumpectomy for early-stage breast cancer with a tolerance profile similar to that of whole breast irradiation.

  20. Implant-supported prostheses versus conventional permanent and removable dentures

    Directory of Open Access Journals (Sweden)

    Koszuta Agnieszka

    2014-06-01

    Full Text Available Social, economic and technological progress results in an increasing range of treatment and rehabilitation methods for patients with partial or complete edentulism. The role of the dentist is to inform the patient about the full range of available missing teeth treatment options leading to complete rehabilitation of the masticatory organ in agreement with the patient’s aesthetic and functional expectations. The aim of the paper was to identify the type of prostheses used by patients before opting for implantsupported teeth replacements, according to the patients’ age, sex, marital status, place of residence and education. The study covered 464 patients, women and men, aged 20-74, treated with dental implants. The patients answered questions in an anonymous questionnaire. The influence of the prosthetic replacement type according to age and marital status was highly statistically significant, whereas it was statistically significant according to sex, place of residence and education. The female respondents who previously used tissue-borne complete or partial dentures opted for implant treatment more frequently. The respondents younger than 40 and between 40-60 years of age who did not previously used any prosthetic replacements opted for implant treatment more frequently. The respondents who did not use any prosthetic replacements decided to undergo implant treatment most frequently, regardless of their marital status, education and place of residence. The patients opted for implant treatment to improve their quality of life, despite the high cost of such therapy.

  1. Ring and peg electrodes for minimally-Invasive and long-term sub-scalp EEG recordings.

    Science.gov (United States)

    Benovitski, Y B; Lai, A; McGowan, C C; Burns, O; Maxim, V; Nayagam, D A X; Millard, R; Rathbone, G D; le Chevoir, M A; Williams, R A; Grayden, D B; May, C N; Murphy, M; D'Souza, W J; Cook, M J; Williams, C E

    2017-09-01

    Minimally-invasive approaches are needed for long-term reliable Electroencephalography (EEG) recordings to assist with epilepsy diagnosis, investigation and more naturalistic monitoring. This study compared three methods for long-term implantation of sub-scalp EEG electrodes. Three types of electrodes (disk, ring, and peg) were fabricated from biocompatible materials and implanted under the scalp in five ambulatory ewes for 3months. Disk electrodes were inserted into sub-pericranial pockets. Ring electrodes were tunneled under the scalp. Peg electrodes were inserted into the skull, close to the dura. EEG was continuously monitored wirelessly. High resolution CT imaging, histopathology, and impedance measurements were used to assess the status of the electrodes at the end of the study. EEG amplitude was larger in the peg compared with the disk and ring electrodes (pEEG, mechanical stability, and lower chewing artifact. Whereas, ring electrode arrays tunneled under the scalp enable minimal surgical techniques to be used for implantation and removal. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. A LabVIEW based experiment system for the efficient collection and analysis of cyclic voltametry and electrode charge capacity measurements.

    Science.gov (United States)

    Detlefsen, D; Hu, Z; Troyk, P R

    2006-01-01

    Cyclic voltametry and recording of stimulation electrode voltage excursions are two critical methods of measurement for understanding the performance of implantable electrodes. Because implanted electrodes cannot easily be replaced, it is necessary to have an a-priori understanding of an electrode's implanted performance and capabilities. In-vitro exhaustive tests are often needed to quantify an electrodes performance. Using commonly available equipment, the human labor cost to conduct this work is immense. Presented is an automated experiment system that is highly configurable that can efficiently conduct a battery of repeatable CV and stimulation recording measurements. Results of preparing 96 electrodes prior to an animal implantation are also discussed.

  3. The Effect of Round Window vs Cochleostomy Surgical Approaches on Cochlear Implant Electrode Position: A Flat-Panel Computed Tomography Study.

    Science.gov (United States)

    Jiam, Nicole T; Jiradejvong, Patpong; Pearl, Monica S; Limb, Charles J

    2016-09-01

    The round window insertion (RWI) and cochleostomy approaches are the 2 most common surgical techniques used in cochlear implantation (CI). However, there is no consensus on which approach is ideal for electrode array insertion, in part because visualization of intracochlear electrode position is challenging, so postoperative assessment of intracochlear electrode contact is lacking. To measure and compare electrode array position between RWI and cochleostomy approaches for CI insertion. Retrospective case-comparison study of 17 CI users with Med-El standard-length electrode arrays who underwent flat-panel computed tomography scans after CI surgery at a tertiary referral center. The data was analyzed in October 2015. Flat-panel computed tomography scans were collected between January 1 and August 31, 2013, for 22 electrode arrays. The surgical technique was identified by a combination of operative notes and imaging. Eight cochleae underwent RWI and 14 cochleae underwent cochleostomy approaches anterior and inferior to the round window. Interscalar electrode position and electrode centroid distance to the osseous spiral lamina, lateral bony wall, and central axis of the modiolus. Nine participants were men, and 8, women; the mean age was 54.4 (range, 21-64) years. Electrode position was significantly closer to cochlear neural elements with RWI than cochleostomy approaches. Between the 2 surgical approaches, the RWI technique produced shorter distances between the electrode and the modiolus (mean difference, -0.33 [95% CI, -0.29 to -0.39] mm in the apical electrode; -1.42 [95% CI, -1.24 to -1.57] mm in the basal electrode). This difference, which was most prominent in the first third and latter third of the basal turn, decreased after the basal turn. The RWI approach was associated with an increased likelihood of perimodiolar placement. Opting to use RWI over cochleostomy approaches in CI candidates may position electrodes closer to cochlear neural substrates and

  4. [Multi-channel cochlear implants in patients with Mondini malformation].

    Science.gov (United States)

    Li, Yong-xin; Han, De-min; Zhao, Xiao-tian; Chen, Xue-qing; Kong, Ying; Zheng, Jun; Liu, Bo; Liu, Sha; Mo, Ling-yan; Zhang, Hua; Wang, Shuo

    2004-02-01

    To describe clinical experiences with multi-channel cochlear implantation in patients with Mondini malformation. Among 300 patients who received multi-channel cochlear implants from 1996 to 2002 in Beijing Tongren Hospital, 15 patients were diagnosed with Mondini malformation. A retrospective analysis was performed dealing with the surgical techniques, mapping and rehabilitations characteristics after surgery. 15 patients with normal cochlear structure are consider as control group. Gusher is found more common than the normal cochlear implantation, most of them are serious. The electrodes are inserted in the "cochleostomy" in full length of 13 Patients, 2 pairs of electrodes remains outside of "cochleostomy" in 2 patients. No serious complications occurred after implantation. All patients have auditory sensations. The impedance of the electrodes, the T level, C level and the hearing threshold are similar with the normal cochlear implantation group. The results have no significant difference in compare with normal cochlear group(P > 0.05). Multi-channel cochlear implantation could be performed safely in patients with Mondini malformation. The primary outcome for patients with Mondini malformation are similar to those with normal cochlear structure following the multi-channel cochlear implantation.

  5. Optimization of pillar electrodes in subretinal prosthesis for enhanced proximity to target neurons

    Science.gov (United States)

    Flores, Thomas; Lei, Xin; Huang, Tiffany; Lorach, Henri; Dalal, Roopa; Galambos, Ludwig; Kamins, Theodore; Mathieson, Keith; Palanker, Daniel

    2018-06-01

    Objective. High-resolution prosthetic vision requires dense stimulating arrays with small electrodes. However, such miniaturization reduces electrode capacitance and penetration of electric field into tissue. We evaluate potential solutions to these problems with subretinal implants based on utilization of pillar electrodes. Approach. To study integration of three-dimensional (3D) implants with retinal tissue, we fabricated arrays with varying pillar diameter, pitch, and height, and implanted beneath the degenerate retina in rats (Royal College of Surgeons, RCS). Tissue integration was evaluated six weeks post-op using histology and whole-mount confocal fluorescence imaging. The electric field generated by various electrode configurations was calculated in COMSOL, and stimulation thresholds assessed using a model of network-mediated retinal response. Main results. Retinal tissue migrated into the space between pillars with no visible gliosis in 90% of implanted arrays. Pillars with 10 μm height reached the middle of the inner nuclear layer (INL), while 22 μm pillars reached the upper portion of the INL. Electroplated pillars with dome-shaped caps increase the active electrode surface area. Selective deposition of sputtered iridium oxide onto the cap ensures localization of the current injection to the pillar top, obviating the need to insulate the pillar sidewall. According to computational model, pillars having a cathodic return electrode above the INL and active anodic ring electrode at the surface of the implant would enable six times lower stimulation threshold, compared to planar arrays with circumferential return, but suffer from greater cross-talk between the neighboring pixels. Significance. 3D electrodes in subretinal prostheses help reduce electrode-tissue separation and decrease stimulation thresholds to enable smaller pixels, and thereby improve visual acuity of prosthetic vision.

  6. Angioplastia del seno coronario en el implante de electrodo del ventrículo izquierdo Angioplasty of coronary sinus in left ventricle electrode implant

    Directory of Open Access Journals (Sweden)

    Alejandro Orjuela

    2011-07-01

    Full Text Available Con el incremento de implantes de dispositivos de estimulación cardíaca en pacientes con miocardiopatía dilatada, el diseno día a día más sofisticado de los mismos para satisfacer los requerimientos de los pacientes con cambios anatómicos que surgen como consecuencia de la misma dilatación cardíaca, tales como modificaciones en el calibre, curso, longitud y número de venas coronarias, cada vez se encuentran mayores dificultades para lograr los objetivos anatómicos, en particular el sitio ideal de posicionamiento del electrodo de estimulación ventricular izquierda en el seno coronario. Esta situación limita, en algunos casos, el beneficio terapéutico de esta técnica, viéndose, en ocasiones, en la necesidad de someter al paciente a toracotomía para posicionar el electrodo en el epicardio posterolateral del ventrículo izquierdo. Es así como, con el objetivo de abreviar los tiempos y la morbimortalidad e incrementar el éxito del implante, se disenó una estrategia basada en la técnica de hemodinámica para vencer las obstrucciones de las arterias coronarias y lograr, mediante angioplastia de las estrecheces del seno coronario, un abordaje más preciso a un determinado vaso epicárdico preseleccionado. Se describe la técnica usada en la angioplastia del seno coronario para este propósito.The design of devices of cardiac stimulation in patients with dilated cardiomyopathy has become more sophisticated due to the increment of its implantation, devices that must satisfy the requirements for patients with anatomical changes that appear as a consequence of the cardiac dilation such as caliber modifications, course, length and number of coronary veins. Every time is more difficult to achieve the anatomical objectives, particularly the ideal place for the left ventricular stimulation electrode position in the coronary sinus. This situation limits in some cases the therapeutical benefit of this technique, occasionally facing to the

  7. Sexual function after permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Galbreath, R.W.; Merrick, G.S.; Butler, W.M.; Stipetich, R.L.; Abel, L.J.; Lief, J.H.

    2001-01-01

    Purpose: To determine the incidence of potency preservation following permanent prostate brachytherapy and to evaluate the effect of multiple clinical and treatment parameters on penile erectile function. Materials and Methods: 425 patients underwent permanent prostate brachytherapy from April 1995 to October 1999. 209 patients who were potent prior to brachytherapy and currently not receiving hormonal manipulation were mailed an International Index of Erectile Function (IIEF) questionnaire with a pre-addressed stamped envelope. 180 patients completed and returned the questionnaire. Median patient follow-up was 39 months (range 18-74 months). Pre-implant erectile function was assigned using a three-tiered scoring system (2 = erections always or nearly always sufficient for vaginal penetration; 1 = erections sufficient for vaginal penetration but considered suboptimal; 0 = the inability to obtain erections and/or erections inadequate for vaginal penetration). Post-implant potency was defined as an IIEF score >11. Clinical parameters evaluated for sexual function included patient age, clinical T stage, elapsed time since implantation, hypertension, diabetes mellitus, and tobacco consumption. Evaluated treatment parameters included the utilization of neoadjuvant hormonal manipulation and the choice of isotope. The efficacy of sildenafil citrate in brachytherapy induced erectile dysfunction (ED) was also evaluated. Results: A pre-treatment erectile function score of 2 and 1 were assigned to 126 and 54 patients respectively. With 6 year follow up, 39% of patients maintained potency following prostate brachytherapy with a plateau on the curve. Post-implant preservation of potency (IIEF>11) correlated with pre-implant erectile function (50% versus 14% for pre-implant scores of 2 and 1 respectively, p≤0.0001), patient age (56%, 38%, and 23% for patients <60 years of age, 60-69 years of age, and ≥70 years of age respectively, p=0.012) and a history of diabetes mellitus

  8. Clinical results of sacral neuromodulation for chronic voiding dysfunction using unilateral sacral foramen electrodes.

    Science.gov (United States)

    Weil, E H; Ruiz-Cerdá, J L; Eerdmans, P H; Janknegt, R A; Van Kerrebroeck, P E

    1998-01-01

    The aim of this study was to determine the long-term clinical efficacy and complications of neuromodulation with a unilateral sacral foramen electrode in 36 patients with chronic voiding dysfunction. Following a positive effect of a percutaneous nerve evaluation test, patients underwent open surgery. A permanent electrode was implanted in 24 patients with urge incontinence, in 6 with urgency-frequency syndrome, and in 6 with nonobstructive urinary retention. After an average follow-up period of 37.8 months, 19 patients (52.8%) continue to benefit from the neuromodulation with a significant improvement of symptoms and urodynamic parameters. The median duration of the therapeutic effect for the total study population was longer than 60 months. No significant difference in the median duration of therapeutic effect with regard to sex, the type of voiding disorder, or the implant pulse generator was found. However, in patients with previous psychological disorders the median duration of therapeutic effect was only 12 months (P = 0.008). Complications were mild. In the group of patients in whom the therapeutic effect remains, 37 reoperations have had to be performed. We conclude that although reoperations were needed to overcome technical problems, patients can achieve lasting symptomatic improvement. Since technical changes in the equipment have reduced the number of complications, even better results can be expected in terms of the reoperation rate.

  9. Analysis of prostate-specific antigen bounce after I125 permanent seed implant for localised prostate cancer

    International Nuclear Information System (INIS)

    Mitchell, Darren M.; Swindell, Ric; Elliott, Tony; Wylie, James P.; Taylor, Cathy M.; Logue, John P.

    2008-01-01

    Background and purpose: To report on the incidence of benign prostate-specific antigen bounce following permanent I 125 prostate brachytherapy, to describe the associations in our population and review the relationship of bounce to subsequent biochemical failure. Materials and methods: From February 2000 to May 2005, 374 patients with localised prostate cancer were treated with I 125 permanent prostate brachytherapy at a single institution. A prospectively collected database was used to identify cases of prostate-specific antigen (PSA) bounce, defined as a rise of ≥0.2 ng/ml above an initial PSA nadir with subsequent decline to or below that nadir without treatment. The patients who received neo-adjuvant or adjuvant hormone manipulation were excluded. Biochemical failure was determined using the both the ASTRO consensus definition and Phoenix (nadir +2 ng/mL) definition. Results: Two hundred and five patients were identified with a median follow-up of 45 months (24-85). PSA bounce was noted in 79 (37%) men, occurring at a median of 14.8 months (1.7-40.6) following implant. The median peak PSA was 1.8 ng/ml (0.4-7.4) with a bounce magnitude of 0.91 ng/ml (0.2-5.8). When pre- and post-implant factors were assessed for association to bounce, only younger age was statistically significant (p = 0.002). The threshold for biochemical failure as defined by the ASTRO consensus definition (1997) was met in 4 (5%) patients after experiencing bounce as opposed to 19 (15%) non-bounce patients (p = 0.01). The threshold for Phoenix (nadir +2 ng/mL) was met in 6 (7.5%) patients following bounce versus 22 (17%) of non-bounce patients (p = 0.003). Both definitions are prone to false positive calls during bounce. Median PSA velocity during the bounce was 0.08 ng/mL/month (0.02-0.98) and was statistically significantly lower than the median velocity prior to the Phoenix biochemical failure at 0.28 ng/mL/month (0.07-2.04) (p = 0.0005). Conclusion: PSA bounce is a common finding in

  10. Permanent Seed Implant Dosimetry (PSID)TM 4.5 version as isodose and Treatment Planning System (TPS) programme for brachytherapy

    International Nuclear Information System (INIS)

    Indra Saptiama; Moch Subechi; Anung Pujiyanto; Hotman Lubis; Herlan Setiawan

    2014-01-01

    The medical treatment using radiation therapy for cancer diseases is increasingly developed. One of the method used in radiotherapy is brachytherapy. Brachytherapy is radiation therapy method in which a radiation source is implanted in cancer cell directly so the dose accepted by cancer cell is the highest dose and the dose accepted by normal cell is the lowest dose. I-125 Seed have been made successfully in domestic. To support the implant of I-125 seed for brachytherapy needs computer programme for the isodose calculation and Treatment Planning System (TPS). Permanent Seed Implant Dosimetry (PSID) 4.5 is one of the isodose calculation and Treatment Planning System (TPS) programme that is owned by Center for Radioisotope and Radiopharmaceutical-BATAN. In isodose calculation, PSID 4.5 uses 1D formalism and 2D formalism based on AAPM-TG43 (Association of American Physicist in Medicine- Task Group No.43). Anisotropic function on 1D formalism depend on distance function while on 2D formalism count on distance and angle function therefore 2D formalism has isodose calculation better than 1D formalism usage. PSID 4.5 can display the isodose contour of the seed I-125 radiation source in 2 dimension (2D) and 3 dimension (3D). The computer programme of isodose calculation and TPS uses PSID 4.5 is expected able to help planning for seed I-125 implantation process for brachytherapy that used by paramedics and to support the usage of seed I-125 as domestic product. (author)

  11. Stimulation and recording electrodes for neural prostheses

    CERN Document Server

    Pour Aryan, Naser; Rothermel, Albrecht

    2015-01-01

    This book provides readers with basic principles of the electrochemistry of the electrodes used in modern, implantable neural prostheses. The authors discuss the boundaries and conditions in which the electrodes continue to function properly for long time spans, which are required when designing neural stimulator devices for long-term in vivo applications. Two kinds of electrode materials, titanium nitride and iridium are discussed extensively, both qualitatively and quantitatively. The influence of the counter electrode on the safety margins and electrode lifetime in a two electrode system is explained. Electrode modeling is handled in a final chapter.

  12. Impact of target volume coverage with Radiation Therapy Oncology Group (RTOG) 98-05 guidelines for transrectal ultrasound guided permanent Iodine-125 prostate implants

    International Nuclear Information System (INIS)

    Horwitz, Eric M.; Mitra, Raj K.; Uzzo, Robert G.; Das, Indra J.; Pinover, Wayne H.; Hanlon, Alexandra L.; McNeeley, Shawn W.; Hanks, Gerald E.

    2003-01-01

    Purpose: Despite the wide use of permanent prostate implants for the treatment of early stage prostate cancer, there is no consensus for optimal pre-implant planning guidelines that results in maximal post-implant target coverage. The purpose of this study was to compare post-implant target volume coverage and dosimetry between patients treated before and after Radiation Therapy Oncology Group (RTOG) 98-05 guidelines were adopted using several dosimetric endpoints. Materials and methods: Ten consecutively treated patients before the adoption of the RTOG 98-05 planning guidelines were compared with ten consecutively treated patients after implementation of the guidelines. Pre-implant planning for patients treated pre-RTOG was based on the clinical target volume (CTV) defined by the pre-implant TRUS definition of the prostate. The CTV was expanded in each dimension according to RTOG 98-05 and defined as the planning target volume. The evaluation target volume was defined as the post-implant computed tomography definition of the prostate based on RTOG 98-05 protocol recommendations. Implant quality indicators included V 100 , V 90 , V 100 , and Coverage Index (CI). Results: The pre-RTOG median V 100 , V 90 , D 90 , and CI values were 82.8, 88.9%, 126.5 Gy, and 17.1, respectively. The median post-RTOG V 100 , V 90 , D 90 , and CI values were 96.0, 97.8%, 169.2 Gy, and 4.0, respectively. These differences were all statistically significant. Conclusions: Implementation of the RTOG 98-05 implant planning guidelines has increased coverage of the prostate by the prescription isodose lines compared with our previous technique, as indicated by post-implant dosimetry indices such as V 100 , V 90 , D 90 . The CI was also improved significantly with the protocol guidelines. Our data confirms the validity of the RTOG 98-05 implant guidelines for pre-implant planning as it relates to enlargement of the CTV to ensure adequate margin between the CTV and the prescription isodose

  13. Rapid prototyping of flexible intrafascicular electrode arrays by picosecond laser structuring.

    Science.gov (United States)

    Mueller, Matthias; de la Oliva, Natalia; Del Valle, Jaume; Delgado-Martínez, Ignacio; Navarro, Xavier; Stieglitz, Thomas

    2017-12-01

    Interfacing the peripheral nervous system can be performed with a large variety of electrode arrays. However, stimulating and recording a nerve while having a reasonable amount of channels limits the number of available systems. Translational research towards human clinical trial requires device safety and biocompatibility but would benefit from design flexibility in the development process to individualize probes. We selected established medical grade implant materials like precious metals and Parylene C to develop a rapid prototyping process for novel intrafascicular electrode arrays using a picosecond laser structuring. A design for a rodent animal model was developed in conjunction with an intrafascicular implantation strategy. Electrode characterization and optimization was performed first in saline solution in vitro before performance and biocompatibility were validated in sciatic nerves of rats in chronic implantation. The novel fabrication process proved to be suitable for prototyping and building intrafascicular electrode arrays. Electrochemical properties of the electrode sites were enhanced and tested for long-term stability. Chronic implantation in the sciatic nerve of rats showed good biocompatibility, selectivity and stable stimulation thresholds. Established medical grade materials can be used for intrafascicular nerve electrode arrays when laser structuring defines structure size in the micro-scale. Design flexibility reduces re-design cycle time and material certificates are beneficial support for safety studies on the way to clinical trials.

  14. Rapid prototyping of flexible intrafascicular electrode arrays by picosecond laser structuring

    Science.gov (United States)

    Mueller, Matthias; de la Oliva, Natalia; del Valle, Jaume; Delgado-Martínez, Ignacio; Navarro, Xavier; Stieglitz, Thomas

    2017-12-01

    Objective. Interfacing the peripheral nervous system can be performed with a large variety of electrode arrays. However, stimulating and recording a nerve while having a reasonable amount of channels limits the number of available systems. Translational research towards human clinical trial requires device safety and biocompatibility but would benefit from design flexibility in the development process to individualize probes. Approach. We selected established medical grade implant materials like precious metals and Parylene C to develop a rapid prototyping process for novel intrafascicular electrode arrays using a picosecond laser structuring. A design for a rodent animal model was developed in conjunction with an intrafascicular implantation strategy. Electrode characterization and optimization was performed first in saline solution in vitro before performance and biocompatibility were validated in sciatic nerves of rats in chronic implantation. Main results. The novel fabrication process proved to be suitable for prototyping and building intrafascicular electrode arrays. Electrochemical properties of the electrode sites were enhanced and tested for long-term stability. Chronic implantation in the sciatic nerve of rats showed good biocompatibility, selectivity and stable stimulation thresholds. Significance. Established medical grade materials can be used for intrafascicular nerve electrode arrays when laser structuring defines structure size in the micro-scale. Design flexibility reduces re-design cycle time and material certificates are beneficial support for safety studies on the way to clinical trials.

  15. Right versus left parasternal electrode position in the entirely subcutaneous ICD.

    Science.gov (United States)

    Bettin, Markus; Dechering, Dirk; Frommeyer, Gerrit; Larbig, Robert; Löher, Andreas; Reinke, Florian; Köbe, Julia; Eckardt, Lars

    2018-05-01

    The subcutaneous implantable cardioverter defibrillator (S-ICD ® ) has been established as an alternative to conventional transvenous ICD for the prevention of sudden cardiac death. Initial studies have shown safety and efficacy of the system with a left parasternal (LP) electrode. However, several case studies reported a right parasternal (RP) position. The purpose of this study was to analyze shock efficacy and safety of an RP electrode position. Between June 2010 and May 2016, 120 S-ICD ® were implanted at our institution. On the basis of the heart location on preoperative chest radiography (CXR), the investigators decided on an RP (n = 52) or LP electrode position (n = 68). All perioperative induced VF episodes, and spontaneous appropriate and inappropriate episodes during follow-up were analyzed. Patients with an RP electrode did not differ in terms of age, sex, or ejection fraction. A statistically significant difference in underlying cardiac disease was observed between the RP and LP electrode group, with more patients with channelopathies in the RP electrode group and more patients with non-ischemic cardiomyopathy in the LP electrode group. During a mean follow-up of 24.3 ± 19.5 months, 27 appropriate (19 in the LP group and 8 in the RP group) and 28 inappropriate (18 LP and 10 RP) ICD shocks occurred (p value = NS). In the present study, an RP electrode position was chosen on the basis of chest radiographic characteristics and was efficient in terms of sensing and shock efficacy. Thus, a right-sided electrode implant might be an alternative if a left-sided electrode implant is inadequate. It might also be favorable for young patients with narrow heart silhouettes in the midsagittal position.

  16. Reliability of spring interconnects for high channel-count polyimide electrode arrays

    Science.gov (United States)

    Khan, Sharif; Ordonez, Juan Sebastian; Stieglitz, Thomas

    2018-05-01

    Active neural implants with a high channel-count need robust and reliable operational assembly for the targeted environment in order to be classified as viable fully implantable systems. The discrete functionality of the electrode array and the implant electronics is vital for intact assembly. A critical interface exists at the interconnection sites between the electrode array and the implant electronics, especially in hybrid assemblies (e.g. retinal implants) where electrodes and electronics are not on the same substrate. Since the interconnects in such assemblies cannot be hermetically sealed, reliable protection against the physiological environment is essential for delivering high insulation resistance and low defusibility of salt ions, which are limited in complexity by current assembly techniques. This work reports on a combination of spring-type interconnects on a polyimide array with silicone rubber gasket insulation for chronically active implantable systems. The spring design of the interconnects on the backend of the electrode array compensates for the uniform thickness of the sandwiched gasket during bonding in assembly and relieves the propagation of extrinsic stresses to the bulk polyimide substrate. The contact resistance of the microflex-bonded spring interconnects with the underlying metallized ceramic test vehicles and insulation through the gasket between adjacent contacts was investigated against the MIL883 standard. The contact and insulation resistances remained stable in the exhausting environmental conditions.

  17. System of fabricating a flexible electrode array

    Energy Technology Data Exchange (ETDEWEB)

    Krulevitch, Peter [Pleasanton, CA; Polla, Dennis L [Roseville, MN; Maghribi, Mariam N [Davis, CA; Hamilton, Julie [Tracy, CA; Humayun, Mark S [La Canada, CA; Weiland, James D [Valencia, CA

    2012-01-28

    An image is captured or otherwise converted into a signal in an artificial vision system. The signal is transmitted to the retina utilizing an implant. The implant consists of a polymer substrate made of a compliant material such as poly(dimethylsiloxane) or PDMS. The polymer substrate is conformable to the shape of the retina. Electrodes and conductive leads are embedded in the polymer substrate. The conductive leads and the electrodes transmit the signal representing the image to the cells in the retina. The signal representing the image stimulates cells in the retina.

  18. System of fabricating a flexible electrode array

    Science.gov (United States)

    Krulevitch, Peter; Polla, Dennis L.; Maghribi, Mariam N.; Hamilton, Julie; Humayun, Mark S.; Weiland, James D.

    2010-10-12

    An image is captured or otherwise converted into a signal in an artificial vision system. The signal is transmitted to the retina utilizing an implant. The implant consists of a polymer substrate made of a compliant material such as poly(dimethylsiloxane) or PDMS. The polymer substrate is conformable to the shape of the retina. Electrodes and conductive leads are embedded in the polymer substrate. The conductive leads and the electrodes transmit the signal representing the image to the cells in the retina. The signal representing the image stimulates cells in the retina.

  19. A Mid-scala Cochlear Implant Electrode Design Achieves a Stable Post-surgical Position in the Cochlea of Patients Over Time-A Prospective Observational Study.

    Science.gov (United States)

    Dees, Guido; Smits, Jeroen Jules; Janssen, A Miranda L; Hof, Janny R; Gazibegovic, Dzemal; Hoof, Marc van; Stokroos, Robert J

    2018-04-01

    Cochlear implant (CI) electrode design impacts the clinical performance of patients. Stability and the occurrence of electrode array migration, which is the postoperative movement of the electrode array, were investigated using a mid-scalar electrode array and postoperative image analysis. A prospective observational study was conducted. A mid-scalar electrode was surgically placed using a mastoidectomy, followed by a posterior tympanotomy and an extended round-window or cochleostomy insertion. A few days after surgery and 3 months later Cone Beam Computed Tomography (CBCT) was performed. The two different CBCT's were fused, and the differences between the electrode positions in three dimensions were calculated (the migration). A migration greater than 0.5 mm was deemed clinically relevant. Fourteen subjects participated. The mid-scalar electrode migrated in one patient (7%). This did not lead to the extrusion of an electrode contact. The mean migration of every individual electrode contact in all patients was 0.36 mm (95% confidence interval 0.22-0.50 mm), which approximates to the estimated measurement error of the CBCT technique. A mid-scalar electrode array achieves a stable position in the cochlea in a small but representative group of patients. The methods applied in this work can be used for providing postoperative feedback for surgeons and for benchmarking electrode designs.

  20. Development of virtual patient models for permanent implant brachytherapy Monte Carlo dose calculations: interdependence of CT image artifact mitigation and tissue assignment.

    Science.gov (United States)

    Miksys, N; Xu, C; Beaulieu, L; Thomson, R M

    2015-08-07

    This work investigates and compares CT image metallic artifact reduction (MAR) methods and tissue assignment schemes (TAS) for the development of virtual patient models for permanent implant brachytherapy Monte Carlo (MC) dose calculations. Four MAR techniques are investigated to mitigate seed artifacts from post-implant CT images of a homogeneous phantom and eight prostate patients: a raw sinogram approach using the original CT scanner data and three methods (simple threshold replacement (STR), 3D median filter, and virtual sinogram) requiring only the reconstructed CT image. Virtual patient models are developed using six TAS ranging from the AAPM-ESTRO-ABG TG-186 basic approach of assigning uniform density tissues (resulting in a model not dependent on MAR) to more complex models assigning prostate, calcification, and mixtures of prostate and calcification using CT-derived densities. The EGSnrc user-code BrachyDose is employed to calculate dose distributions. All four MAR methods eliminate bright seed spot artifacts, and the image-based methods provide comparable mitigation of artifacts compared with the raw sinogram approach. However, each MAR technique has limitations: STR is unable to mitigate low CT number artifacts, the median filter blurs the image which challenges the preservation of tissue heterogeneities, and both sinogram approaches introduce new streaks. Large local dose differences are generally due to differences in voxel tissue-type rather than mass density. The largest differences in target dose metrics (D90, V100, V150), over 50% lower compared to the other models, are when uncorrected CT images are used with TAS that consider calcifications. Metrics found using models which include calcifications are generally a few percent lower than prostate-only models. Generally, metrics from any MAR method and any TAS which considers calcifications agree within 6%. Overall, the studied MAR methods and TAS show promise for further retrospective MC dose

  1. American brachytherapy society recommends no change for prostate permanent implant dose prescriptions using iodine-125 or palladium-103

    International Nuclear Information System (INIS)

    Rivard, M.J.; Butler, W.M.; Merrick, G.S.; Devlin, P.M.; Hayes, J.K.; Hearn, R.A.; Lief, E.P.; Meigooni, A.S.; Williamson, J.F.

    2008-01-01

    Purpose - In 2004, the American Association of Physicists in Medicine (AAPM) issued a report outlining recommended 125 I and 103 Pd datasets for consistency in calculating brachytherapy dose distributions. In 2005, to aid evaluating the clinical impact of implementing these datasets, the AAPM assessed the historical dependence of how prescribed doses differed from administered doses for 125 I and 103 Pd for permanent implantation of the prostate. Consequently, the American Brachytherapy Society (ABS) considered the nature of these changes towards issuing recommended dose prescriptions for 125 I and 103 Pd interstitial brachytherapy implants for mono-therapy and standard boosts. Methods and materials - An investigation was performed of the 2005 AAPM analysis to determine changes in administered dose while affixing prescribed dose using 2004 AAPM 125 I and 103 Pd brachytherapy dosimetry datasets for prostate implants. For 125 I and 103 Pd, administered dose would change by +1.4% and +4.2%, respectively. The biological and societal impact of changing prescribed dose was considered. Results - Based on the need for clinical constancy and in recognition of overall uncertainties, the ABS recommends immediate implementation of the 2004 AAPM consensus brachytherapy dosimetry datasets and no changes to 125 I and 103 Pd dose prescriptions at this time. Conclusions - Radiation oncologists should continue to prescribe mono-therapy doses of 145 Gy and 125 Gy for 125 I and 105 Pd, respectively, and standard boost doses of 100-110 Gy and 90-100 Gy for 125 I and 103 Pd, respectively. (authors)

  2. Urethral dose and increment of international prostate symptom score (IPSS) in transperineal permanent interstitial implant (TPI) of prostate cancer

    International Nuclear Information System (INIS)

    Murakami, N.; Itami, J.; Okuma, K.; Marino, H.; Ban, T.; Nakazato, M.; Kanai, K.; Naoi, K.; Fuse, M.; Nakagawa, K.

    2008-01-01

    Purpose: to find the factors which influence the acute increment of international prostate symptom score (IPSS) after transperineal permanent interstitial implant (TPI) using 125 I seeds. Patients and methods: from April 2004 through September 2006, 104 patients with nonmetastatic prostate cancer underwent TPI without external-beam irradiation. Median patient age was 70 years with a median follow-up of 13.0 months. 73 patients (70%) received neoadjuvant hormone therapy. The increment of IPSS was defined as the difference between pre- and postimplant maximal IPSS. Clinical, treatment, and dosimetric parameters evaluated included age, initial prostate-specific antigen, Gleason Score, neoadjuvant hormone therapy, initial IPSS, post-TPI prostatic volume, number of implanted seeds, prostate V 100 , V 150 , D 90 , urethral D max , and urethral D 90 . In order to further evaluate detailed urethral doses, the base and apical urethra were defined and the dosimetric parameters were calculated. Results: the IPSS peaked 3 months after TPI and returned to baseline at 12-15 months. Multivariate analysis demonstrated a statistically significant correlation of post-TPI prostatic volume, number of implanted seeds, and the dosimetric parameters of the base urethra with IPSS increment. Conclusion: the base urethra appears to be susceptible to radiation and the increased dose to this region deteriorates IPSS. It remains unclear whether the base urethral dose relates to the incidence of late urinary morbidities. (orig.)

  3. Cochlear implantation in a bilateral Mondini dysplasia.

    Science.gov (United States)

    Turrini, M; Orzan, E; Gabana, M; Genovese, E; Arslan, E; Fisch, U

    1997-01-01

    We report the speech perception progress and programming procedures of a case of congenital profound deafness and bilateral Mondini dysplasia implanted with a Nucleus 20 + 2 cochlear implant at the age of six. Unclear relations between electrodes array and cochlear partition made implant programming difficult and non-standard procedures were set. Cochlear implantation may give excellent rehabilitative results also in cochleae with malformation.

  4. Biomimetic hydrogels for biosensor implant biocompatibility: electrochemical characterization using micro-disc electrode arrays (MDEAs).

    Science.gov (United States)

    Justin, Gusphyl; Finley, Stephen; Abdur Rahman, Abdur Rub; Guiseppi-Elie, Anthony

    2009-02-01

    Our interest is in the development of engineered microdevices for continuous remote monitoring of intramuscular lactate, glucose, pH and temperature during post-traumatic hemorrhaging. Two important design considerations in the development of such devices for in vivo diagnostics are discussed; the utility of micro-disc electrode arrays (MDEAs) for electrochemical biosensing and the application of biomimetic, bioactive poly(HEMA)-based hydrogel composites for implant biocompatibility. A poly(HEMA)-based hydrogel membrane containing polyethylene glycol (PEG) was UV cross-linked with tetraethyleneglycol diacrylate following application to MDEAs (50 mum discs) and to 250 mum diameter gold electrodes within 8-well culture ware. Cyclic voltammetry (CV) of the MDEAs revealed a reduction in the apparent diffusion coefficient of ferrocenemonocarboxylic acid (FcCO(2)H), from 6.68 x 10(-5) to 6.74 x 10(-6) cm(2)/s for the uncoated and 6 mum thick hydrogel coated devices, respectively. Single frequency (4 kHz) temporal impedance measurements of the hydrogels in the 8-well culture ware showed a reversible 5% change in the absolute impedance of the hydrogels when exposed to a pH change between 6.1 to 7.2 and a 20% drop between pH 6.1 and 8.8.

  5. Recursive grid partitioning on a cortical surface model: an optimized technique for the localization of implanted subdural electrodes.

    Science.gov (United States)

    Pieters, Thomas A; Conner, Christopher R; Tandon, Nitin

    2013-05-01

    .2 to 11.7 mm for an individual electrode, with mean errors ranging between 2.9 and 4.1 mm depending on the method used. The authors also noted a larger error in all methods that used CT scans alone to localize electrodes compared with those that used both postoperative CT and postoperative MRI. The large mean errors reported with these methods are liable to affect intermodal data comparisons (for example, with functional mapping techniques) and may impact surgical decision making. The authors have presented several aspects of using new techniques to visualize electrodes implanted for localizing epilepsy. The ability to use automated labeling schemas to denote which gyrus a particular electrode overlies is potentially of great utility in planning resections and in corroborating the results of extraoperative stimulation mapping. Dilation of the pial mesh model provides, for the first time, a sense of the cortical surface not sampled by the electrode, and the potential roles this "electrophysiologically hidden" cortex may play in both eloquent function and seizure onset.

  6. Clinical and Echocardiographic Outcomes Following Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement: Meta-Analysis and Meta-Regression.

    Science.gov (United States)

    Mohananey, Divyanshu; Jobanputra, Yash; Kumar, Arnav; Krishnaswamy, Amar; Mick, Stephanie; White, Jonathon M; Kapadia, Samir R

    2017-07-01

    Transcatheter aortic valve replacement has become the procedure of choice for inoperable, high-risk, and many intermediate-risk patients with aortic stenosis. Conduction abnormalities are a common finding after transcatheter aortic valve replacement and often result in permanent pacemaker (PPM) implantation. Data pertaining to the clinical impact of PPM implantation are controversial. We used meta-analysis techniques to summarize the effect of PPM implantation on clinical and echocardiographic outcomes after transcatheter aortic valve replacement. Data were summarized as Mantel-Haenszel relative risk (RR) and 95% confidence intervals (CIs) for dichotomous variables and as standardized mean difference and 95% CI for continuous variables We used the Higgins I 2 statistic to evaluate heterogeneity. We found that patients with and without PPM have similar all-cause mortality (RR, 0.85; 95% CI, 0.70-1.03), cardiovascular mortality (RR, 0.84; 95% CI, 0.59-1.18), myocardial infarction (RR, 0.47; 95% CI, 0.20-1.11), and stroke (RR, 1.26; 95% CI, 0.70-2.26) at 30 days. The groups were also comparable in all-cause mortality (RR, 1.03; 95% CI, 0.92-1.16), cardiovascular mortality (RR, 0.69; 95% CI, 0.39-1.24), myocardial infarction (RR, 0.58; 95% CI, 0.30-1.13), and stroke (RR, 0.70; 95% CI, 0.47-1.04) at 1 year. We observed that the improvement in left ventricular ejection fraction was significantly greater in the patients without PPM (standardized mean difference, 0.22; 95% CI, 0.12-0.32). PPM implantation is not associated with increased risk of all-cause mortality, cardiovascular mortality, stroke, or myocardial infarction both at short- and long-term follow-up. However, PPM is associated with impaired left ventricular ejection fraction recovery post-transcatheter aortic valve replacement. © 2017 American Heart Association, Inc.

  7. SU-E-T-123: Anomalous Altitude Effect in Permanent Implant Brachytherapy Seeds

    International Nuclear Information System (INIS)

    Watt, E; Spencer, DP; Meyer, T

    2015-01-01

    Purpose: Permanent seed implant brachytherapy procedures require the measurement of the air kerma strength of seeds prior to implant. This is typically accomplished using a well-type ionization chamber. Previous measurements (Griffin et al., 2005; Bohm et al., 2005) of several low-energy seeds using the air-communicating HDR 1000 Plus chamber have demonstrated that the standard temperature-pressure correction factor, P TP , may overcompensate for air density changes induced by altitude variations by up to 18%. The purpose of this work is to present empirical correction factors for two clinically-used seeds (IsoAid ADVANTAGE™ 103 Pd and Nucletron selectSeed 125 I) for which empirical altitude correction factors do not yet exist in the literature when measured with the HDR 1000 Plus chamber. Methods: An in-house constructed pressure vessel containing the HDR 1000 Plus well chamber and a digital barometer/thermometer was pumped or evacuated, as appropriate, to a variety of pressures from 725 to 1075 mbar. Current measurements, corrected with P TP , were acquired for each seed at these pressures and normalized to the reading at ‘standard’ pressure (1013.25 mbar). Results: Measurements in this study have shown that utilization of P TP can overcompensate in the corrected current reading by up to 20% and 17% for the IsoAid Pd-103 and the Nucletron I-125 seed respectively. Compared to literature correction factors for other seed models, the correction factors in this study diverge by up to 2.6% and 3.0% for iodine (with silver) and palladium respectively, indicating the need for seed-specific factors. Conclusion: The use of seed specific altitude correction factors can reduce uncertainty in the determination of air kerma strength. The empirical correction factors determined in this work can be applied in clinical quality assurance measurements of air kerma strength for two previously unpublished seed designs (IsoAid ADVANTAGE™ 103 Pd and Nucletron selectSeed 125 I

  8. SU-E-T-123: Anomalous Altitude Effect in Permanent Implant Brachytherapy Seeds

    Energy Technology Data Exchange (ETDEWEB)

    Watt, E; Spencer, DP; Meyer, T [University of Calgary and Tom Baker Cancer Centre, Calgary, AB (Canada)

    2015-06-15

    Purpose: Permanent seed implant brachytherapy procedures require the measurement of the air kerma strength of seeds prior to implant. This is typically accomplished using a well-type ionization chamber. Previous measurements (Griffin et al., 2005; Bohm et al., 2005) of several low-energy seeds using the air-communicating HDR 1000 Plus chamber have demonstrated that the standard temperature-pressure correction factor, P{sub TP}, may overcompensate for air density changes induced by altitude variations by up to 18%. The purpose of this work is to present empirical correction factors for two clinically-used seeds (IsoAid ADVANTAGE™ {sup 103}Pd and Nucletron selectSeed {sup 125}I) for which empirical altitude correction factors do not yet exist in the literature when measured with the HDR 1000 Plus chamber. Methods: An in-house constructed pressure vessel containing the HDR 1000 Plus well chamber and a digital barometer/thermometer was pumped or evacuated, as appropriate, to a variety of pressures from 725 to 1075 mbar. Current measurements, corrected with P{sub TP}, were acquired for each seed at these pressures and normalized to the reading at ‘standard’ pressure (1013.25 mbar). Results: Measurements in this study have shown that utilization of P{sub TP} can overcompensate in the corrected current reading by up to 20% and 17% for the IsoAid Pd-103 and the Nucletron I-125 seed respectively. Compared to literature correction factors for other seed models, the correction factors in this study diverge by up to 2.6% and 3.0% for iodine (with silver) and palladium respectively, indicating the need for seed-specific factors. Conclusion: The use of seed specific altitude correction factors can reduce uncertainty in the determination of air kerma strength. The empirical correction factors determined in this work can be applied in clinical quality assurance measurements of air kerma strength for two previously unpublished seed designs (IsoAid ADVANTAGE™ {sup 103}Pd and

  9. Wettability control of polystyrene by ion implantation

    International Nuclear Information System (INIS)

    Suzuki, Yoshiaki; Kusakabe, Masahiro; Iwaki, Masaya

    1994-01-01

    The permanent effects of ion implantation on the improvement of wettability of polystyrene is investigated in relation to ion species and fluences. The He + , Ne + , Na + , N 2 + , O 2 + , Ar + , K + and Kr + ion implantations were performed at energies of 50 and 150 keV at room temperature. The fluences ranged from 1x10 15 to 1x10 17 ions/cm 2 . The results showed that the contact angle of water for Na + and K + implanted polystyrene decreased from 87 to 0 , as the fluences increased to 1x10 17 ions/cm 2 at an energy of 50 keV. The contact angle for Na + and K + implanted polystyrene did not change under ambient room conditions, even when time elapsed. However, the contact an gle for He + , C + , O + , Ne + , N 2 + , O 2 + , Ar + , and Kr + ion implanted specimens decreased slightly immediately after ion implantation. Results of X-ray photoelectron spectroscopy showed that the increase in the Na content in the surface of Na + implanted specimens were observed with increasing fluence. It is concluded that permanent improvement in wettability was caused by doping effects rather than by radiation effects from Na + and K + ion implantation. ((orig.))

  10. Pacemaker implantation complication rates in elderly and young patients

    Directory of Open Access Journals (Sweden)

    Özcan KS

    2013-08-01

    Full Text Available Kazim Serhan Özcan, Damirbek Osmonov, Servet Altay, Cevdet Dönmez, Ersin Yildirim, Ceyhan Türkkan, Baris Güngör, Ahmet Ekmekçi, Ahmet Taha Alper, Kadir Gürkan, İzzet ErdinlerDepartment of Cardiology, Siyami Ersek Cardiovascular and Thoracic Surgery Center, Istanbul, TurkeyAims: To evaluate the complication rate differences between elderly and younger patients who receive a permanent pacemaker implantation.Methods: We reviewed all cases admitted to our institution between January 2008 and June 2009 with symptomatic bradyarrhythmia for whom a permanent pacemaker was implanted. Beginning in June 2009, we prospectively collected data from all patients with the same diagnosis and procedure. The frequency of complications due to the pacemaker implantation procedure was evaluated and compared between young (<70 years old and elderly (≥70 years old patients.Results: Among 574 patients with a permanent pacemaker, 259 patients (45.1% were below and 315 patients (54.9% were above or at 70 years of age. There were 240 (92.7% and 19 (7.3% dual-chamber pacemaker (DDD and single-chamber pacemaker (VVI implanted patients in the younger group, and 291 (76.8% and 73 (23.2% DDD and VVI pacemaker implanted patients in the elderly group, respectively. The complication rate was 39 (15.1% out of 259 young patients and 24 (7.6% out of 315 elderly patients. Postprocedural complications were statistically lower in the elderly patients than in younger patients (P = 0.005.Conclusion: A pacemaker implantation performed by an experienced operator is a safe procedure for patients of advanced age. The patients who are above 70 years old may have less complication rates than the younger patients.Keywords: complications of pacemaker implantation, elderly patients, permanent pacemaker

  11. Spatial channel interactions in cochlear implants

    Science.gov (United States)

    Tang, Qing; Benítez, Raul; Zeng, Fan-Gang

    2011-08-01

    The modern multi-channel cochlear implant is widely considered to be the most successful neural prosthesis owing to its ability to restore partial hearing to post-lingually deafened adults and to allow essentially normal language development in pre-lingually deafened children. However, the implant performance varies greatly in individuals and is still limited in background noise, tonal language understanding, and music perception. One main cause for the individual variability and the limited performance in cochlear implants is spatial channel interaction from the stimulating electrodes to the auditory nerve and brain. Here we systematically examined spatial channel interactions at the physical, physiological, and perceptual levels in the same five modern cochlear implant subjects. The physical interaction was examined using an electric field imaging technique, which measured the voltage distribution as a function of the electrode position in the cochlea in response to the stimulation of a single electrode. The physiological interaction was examined by recording electrically evoked compound action potentials as a function of the electrode position in response to the stimulation of the same single electrode position. The perceptual interactions were characterized by changes in detection threshold as well as loudness summation in response to in-phase or out-of-phase dual-electrode stimulation. To minimize potentially confounding effects of temporal factors on spatial channel interactions, stimulus rates were limited to 100 Hz or less in all measurements. Several quantitative channel interaction indexes were developed to define and compare the width, slope and symmetry of the spatial excitation patterns derived from these physical, physiological and perceptual measures. The electric field imaging data revealed a broad but uniformly asymmetrical intracochlear electric field pattern, with the apical side producing a wider half-width and shallower slope than the basal

  12. Sacral neuromodulation in the treatment of the unstable bladder.

    Science.gov (United States)

    Bosch, J L

    1998-07-01

    Sacral neuromodulation as a treatment for urge incontinence in patients with an unstable bladder is the subject of ongoing clinical studies. Although approximately 75% of the patients treated with a permanent sacral foramen electrode implant have experienced significant improvements, it is now also clear that there is an initial failure rate of about 25%. Recent studies have pointed out the importance of improved patient selection on the basis of sex differences, urodynamic parameters and psychological factors. Also, newer forms of test stimulation and permanent electrode implantation are being explored in an effort to improve on the present results.

  13. Comparison of Combined X-Ray Radiography and Magnetic Resonance (XMR) Imaging-Versus Computed Tomography-Based Dosimetry for the Evaluation of Permanent Prostate Brachytherapy Implants

    International Nuclear Information System (INIS)

    Acher, Peter; Rhode, Kawal; Morris, Stephen; Gaya, Andrew; Miquel, Marc; Popert, Rick; Tham, Ivan; Nichol, Janette; McLeish, Kate; Deehan, Charles; Dasgupta, Prokar; Beaney, Ronald; Keevil, Stephen F.

    2008-01-01

    Purpose: To present a method for the dosimetric analysis of permanent prostate brachytherapy implants using a combination of stereoscopic X-ray radiography and magnetic resonance (MR) imaging (XMR) in an XMR facility, and to compare the clinical results between XMR- and computed tomography (CT)-based dosimetry. Methods and Materials: Patients who had received nonstranded iodine-125 permanent prostate brachytherapy implants underwent XMR and CT imaging 4 weeks later. Four observers outlined the prostate gland on both sets of images. Dose-volume histograms (DVHs) were derived, and agreement was compared among the observers and between the modalities. Results: A total of 30 patients were evaluated. Inherent XMR registration based on prior calibration and optical tracking required a further automatic seed registration step that revealed a median root mean square registration error of 4.2 mm (range, 1.6-11.4). The observers agreed significantly more closely on prostate base and apex positions as well as outlining contours on the MR images than on those from CT. Coefficients of variation were significantly higher for observed prostate volumes, D90, and V100 parameters on CT-based dosimetry as opposed to XMR. The XMR-based dosimetry showed little agreement with that from CT for all observers, with D90 95% limits of agreement ranges of 65, 118, 79, and 73 Gy for Observers 1, 2, 3, and 4, respectively. Conclusions: The study results showed that XMR-based dosimetry offers an alternative to other imaging modalities and registration methods with the advantages of MR-based prostate delineation and confident three-dimensional reconstruction of the implant. The XMR-derived dose-volume histograms differ from the CT-derived values and demonstrate less interobserver variability

  14. Round window electrode insertion potentiates retention in the scala tympani.

    Science.gov (United States)

    Connor, Stephen E J; Holland, N Julian; Agger, Andreas; Leong, Annabelle C; Varghese, Re Ajay; Jiang, Dan; Fitzgerald O'Connor, Alec

    2012-09-01

    The round window membrane (RWM)-intentioned approach is superior to the traditional bony cochleostomy (BC) approach in obtaining electrode placement within the scala tympani (ST). Cochlear implant outcome is influenced by several factors, including optimal placement and retention of the electrode array within the ST. The present study aimed to assess whether the RWM route is superior to a traditional BC for placement and retention of the electrode array in the ST. This was a prospective consecutive non-randomized comparison study. All patients were implanted with the Advanced Bionics 1J electrode array. The RWM approach (n = 32) was compared with a traditional BC group (n = 33). The outcome measure was the electrode position as judged within the scalar chambers at four points along the basal turn using postoperative computed tomography (CT). When the mean position scores were compared, the RWM-intentioned group had significantly more electrodes directed towards the ST compartment than the BC group (p scala vestibuli.

  15. Localizing and tracking electrodes using stereovision in epilepsy cases

    Science.gov (United States)

    Fan, Xiaoyao; Ji, Songbai; Roberts, David W.; Paulsen, Keith D.

    2015-03-01

    In epilepsy cases, subdural electrodes are often implanted to acquire intracranial EEG (iEEG) for seizure localization and resection planning. However, the electrodes may shift significantly between implantation and resection, during the time that the patient is monitored for iEEG recording. As a result, the accuracy of surgical planning based on electrode locations at the time of resection can be compromised. Previous studies have only quantified the electrode shift with respect to the skull, but not with respect to the cortical surface, because tracking cortical shift between surgeries is challenging. In this study, we use an intraoperative stereovision (iSV) system to visualize and localize the cortical surface as well as electrodes, record three-dimensional (3D) locations of the electrodes in MR space at the time of implantation and resection, respectively, and quantify the raw displacements, i.e., with respect to the skull. Furthermore, we track the cortical surface and quantify the shift between surgeries using an optical flow (OF) based motion-tracking algorithm. Finally, we compute the electrode shift with respect to the cortical surface by subtracting the cortical shift from raw measured displacements. We illustrate the method using one patient example. In this particular patient case, the results show that the electrodes not only shifted significantly with respect to the skull (8.79 +/- 3.00 mm in the lateral direction, ranging from 2.88 mm to 12.87 mm), but also with respect to the cortical surface (7.20 +/- 3.58 mm), whereas the cortical surface did not shift significantly in the lateral direction between surgeries (2.23 +/- 0.76 mm).

  16. Simplifying cochlear implant speech processor fitting

    NARCIS (Netherlands)

    Willeboer, C.

    2008-01-01

    Conventional fittings of the speech processor of a cochlear implant (CI) rely to a large extent on the implant recipient's subjective responses. For each of the 22 intracochlear electrodes the recipient has to indicate the threshold level (T-level) and comfortable loudness level (C-level) while

  17. In Vivo Electrochemical Analysis of a PEDOT/MWCNT Neural Electrode Coating

    Directory of Open Access Journals (Sweden)

    Nicolas A. Alba

    2015-10-01

    Full Text Available Neural electrodes hold tremendous potential for improving understanding of brain function and restoring lost neurological functions. Multi-walled carbon nanotube (MWCNT and dexamethasone (Dex-doped poly(3,4-ethylenedioxythiophene (PEDOT coatings have shown promise to improve chronic neural electrode performance. Here, we employ electrochemical techniques to characterize the coating in vivo. Coated and uncoated electrode arrays were implanted into rat visual cortex and subjected to daily cyclic voltammetry (CV and electrochemical impedance spectroscopy (EIS for 11 days. Coated electrodes experienced a significant decrease in 1 kHz impedance within the first two days of implantation followed by an increase between days 4 and 7. Equivalent circuit analysis showed that the impedance increase is the result of surface capacitance reduction, likely due to protein and cellular processes encapsulating the porous coating. Coating’s charge storage capacity remained consistently higher than uncoated electrodes, demonstrating its in vivo electrochemical stability. To decouple the PEDOT/MWCNT material property changes from the tissue response, in vitro characterization was conducted by soaking the coated electrodes in PBS for 11 days. Some coated electrodes exhibited steady impedance while others exhibiting large increases associated with large decreases in charge storage capacity suggesting delamination in PBS. This was not observed in vivo, as scanning electron microscopy of explants verified the integrity of the coating with no sign of delamination or cracking. Despite the impedance increase, coated electrodes successfully recorded neural activity throughout the implantation period.

  18. The electrochemical behavior and surface structure of titanium electrodes modified by ion beams

    International Nuclear Information System (INIS)

    Huang, G.F.; Xie, Z.; Huang, W.Q.; Yang, S.B.; Zhao, L.H.

    2004-01-01

    Industrial grade titanium modified by ion implantation and sputtering was used as electrodes. The effect of ion beam modification on the electrochemical behavior and surface structure of electrodes was investigated. Also discussed is the hydrogen evolution process of the electrode in acidic solution. Several ions such as Fe + , C + , W + , Ni + and others, were implanted into the electrode. The electrochemical tests were carried out in 1N H 2 SO 4 solution at 30±1 deg. C. The electrode potential was measured versus a saturate calomel electrode as a function of immersion time. The cathodic polarization curves were measured by the stable potential static method. The surface layer composition and the chemical state of the electrodes were also investigated by Auger electron spectrometer (AES) and X-ray photoelectron spectroscopy (XPS) technique. The results show that: (1) the stability of modified electrodes depends on the active elements introduced by ion implantation and sputtering deposition. (2) The hydrogen evolution activity of industrial grade titanium may be improved greatly by ion beam modification. (3) Ion beam modification changed the composition and the surface state of electrodes over a certain depth range and forms an activity layer having catalytic hydrogen evolution, which inhibited the absorption of hydrogen and formation of titanium hydride. Thus promoted hydrogen evolution and improved the hydrogen evolution catalytic activity in industrial grade titanium

  19. Use of brachytherapy with permanent implants of iodine-125 in localized prostate cancer; La curietherapie par implants permanents d'I-125 dans le cancer localise de la prostate

    Energy Technology Data Exchange (ETDEWEB)

    Bladou, F.; Serment, G. [Hopital Salvador, Service d' Urologie, 13 - Marseille (France); Salem, N.; Simonian, M. [Hopital Salvador, Dept. de Radiotherapie, 13 - Marseille (France); Rosello, R.; Ternier, F. [Institut Paoli-Calmettes, Dept. de Radiologie, 13 - Marseille (France)

    2002-07-01

    Approximately 15,000 cases of early stage prostate cancer T1 and T2 are diagnosed every year in France by testing for PSA and performing prostatic biopsies. The treatment of these localized forms is based in most cases on radical prostatectomy or nn external beam radiotherapy. Although the ontological results obtained by these two therapeutic methods are satisfactory and equivalent in the long term, the side effects can be important. For a number of years, trans-perineal brachytherapy using permanent implants of iodine -125 or palladium-103 has proved itself as an alternative therapy with equivalent medium to long-term results. The low urinary, digestive and sexual side effects of prostate brachytherapy are important reasons for the enthusiasm among patients and the medical community for this therapy and the growing number of applications and centres which practice it. In September 1998 we started the prostate brachytherapy programmes- in Marseilles with close collaboration between the department of urology of the Hopital Salvator, and the departments of radiotherapy, medical imaging and medical physics of the Institut Paoli-Calmettes. To date, around 250 patients with localized adenocarcinoma of the prostate have benefited from this alternative therapy in our centre. Preliminary results, with a 3 year-follow-up, are comparable to results published in the literature by pioneer teams. (authors)

  20. Pudendal nerve stimulation and block by a wireless-controlled implantable stimulator in cats.

    Science.gov (United States)

    Yang, Guangning; Wang, Jicheng; Shen, Bing; Roppolo, James R; de Groat, William C; Tai, Changfeng

    2014-07-01

    The study aims to determine the functionality of a wireless-controlled implantable stimulator designed for stimulation and block of the pudendal nerve. In five cats under α-chloralose anesthesia, the stimulator was implanted underneath the skin on the left side in the lower back along the sacral spine. Two tripolar cuff electrodes were implanted bilaterally on the pudendal nerves in addition to one bipolar cuff electrode that was implanted on the left side central to the tripolar cuff electrode. The stimulator provided high-frequency (5-20 kHz) biphasic stimulation waveforms to the two tripolar electrodes and low-frequency (1-100 Hz) rectangular pulses to the bipolar electrode. Bladder and urethral pressures were measured to determine the effects of pudendal nerve stimulation (PNS) or block. The maximal (70-100 cmH2O) urethral pressure generated by 20-Hz PNS applied via the bipolar electrode was completely eliminated by the pudendal nerve block induced by the high-frequency stimulation (6-15 kHz, 6-10 V) applied via the two tripolar electrodes. In a partially filled bladder, 20-30 Hz PNS (2-8 V, 0.2 ms) but not 5 Hz stimulation applied via the bipolar electrode elicited a large sustained bladder contraction (45.9 ± 13.4 to 52.0 ± 22 cmH2O). During cystometry, the 5 Hz PNS significantly (p < 0.05) increased bladder capacity to 176.5 ± 27.1% of control capacity. The wireless-controlled implantable stimulator successfully generated the required waveforms for stimulation and block of pudendal nerve, which will be useful for restoring bladder functions after spinal cord injury. © 2013 International Neuromodulation Society.

  1. Role of hormonal therapy in the management of intermediate- to high-risk prostate cancer treated with permanent radioactive seed implantation

    International Nuclear Information System (INIS)

    Lee, Lucille N.; Stock, Richard G.; Stone, Nelson N.

    2002-01-01

    Purpose: To study the impact of hormonal therapy (HTx) on intermediate- to high-risk prostate cancer treated with permanent radioactive seed implantation. Methods and Materials: Patients with Stage T1b-T3bN0 prostate cancer, and Gleason score ≥7 or prostate-specific antigen (PSA) level >10 ng/mL were treated with seed implantation with or without HTx. Their disease was defined as intermediate risk (PSA 10-20, Gleason score 7, or Stage T2b) or high risk (two or more intermediate criteria, or PSA >20 ng/mL, Gleason score 8-10, or Stage T2c-T3). The median follow-up for 201 eligible patients was 42 months (range 18-110). Biochemical failure was defined as a rising PSA >1.0 ng/mL. Pretreatment disease characteristics, implant dose, and HTx were evaluated using univariate and multivariate analyses. Results: HTx significantly improved 5-year actuarial freedom from biochemical failure rate, 79% vs. 54% without HTx. In addition, high-dose, PSA ≤15 ng/mL, intermediate risk, and Stage T2a or lower significantly improved outcome in the univariate analyses. HTx was the most significant predictor of 5-year actuarial freedom from biochemical failure (p <0.0001) in a multivariate analysis. The best outcome was in the intermediate-risk patients treated with a high implant dose and HTx, resulting in a 4-year actuarial freedom from biochemical failure rate of 94%. Conclusion: In this retrospective review, HTx improved outcome in intermediate- to high-risk prostate cancer patients treated with brachytherapy. HTx was the most important prognostic factor in the univariate and multivariate analyses

  2. Electrochemical investigations of ion-implanted oxide films

    International Nuclear Information System (INIS)

    Schultze, J.W.; Danzfuss, B.; Meyer, O.; Stimming, U.

    1985-01-01

    Oxide films (passive films) of 40-50 nm thickness were prepared by anodic polarization of hafnium and titanium electrodes up to 20 V. Multiple-energy ion implantation of palladium, iron and xenon was used in order to obtain modified films with constant concentration profiles of the implanted ions. Rutherford backscattering, X-ray photoelectron spectroscopy measurements and electrochemical charging curves prove the presence of implanted ions, but electrochemical and photoelectrochemical measurements indicate that the dominating effect of ion implantation is the disordering of the oxide film. The capacity of hafnium electrodes increases as a result of an increase in the dielectric constant D. For titanium the Schottky-Mott analysis shows that ion implantation causes an increase in D and the donor concentration N. Additional electronic states in the band gap which are created by the implantation improve the conductivity of the semiconducting or insulating films. This is seen in the enhancement of electron transfer reactions and its disappearance during repassivation and annealing. Energy changes in the band gap are derived from photoelectrochemical measurements; the absorption edge of hafnium oxide films decreases by approximately 2 eV because of ion implantation, but it stays almost constant for titanium oxide films. All changes in electrochemical behavior caused by ion implantation show little variation with the nature of the implanted ion. Hence the dominating effect seems to be a disordering of the oxide. (Auth.)

  3. Creating virtual electrodes with 2D current steering

    Science.gov (United States)

    Spencer, Thomas C.; Fallon, James B.; Shivdasani, Mohit N.

    2018-06-01

    Objective. Current steering techniques have shown promise in retinal prostheses as a way to increase the number of distinct percepts elicitable without increasing the number of implanted electrodes. Previously, it has been shown that ‘virtual’ electrodes can be created between simultaneously stimulated electrode pairs, producing unique cortical response patterns. This study investigated whether virtual electrodes could be created using 2D current steering, and whether these virtual electrodes can produce cortical responses with predictable spatial characteristics. Approach. Normally-sighted eyes of seven adult anaesthetised cats were implanted with a 42-channel electrode array in the suprachoroidal space and multi-unit neural activity was recorded from the visual cortex. Stimuli were delivered to individual physical electrodes, or electrodes grouped into triangular, rectangular, and hexagonal arrangements. Varying proportions of charge were applied to each electrode in a group to ‘steer’ current and create virtual electrodes. The centroids of cortical responses to stimulation of virtual electrodes were compared to those evoked by stimulation of single physical electrodes. Main results. Responses to stimulation of groups of up to six electrodes with equal ratios of charge on each electrode resulted in cortical activation patterns that were similar to those elicited by the central physical electrode (centroids: RM ANOVA on ranks, p  >  0.05 neural spread: one-way ANOVA on Ranks, p  >  0.05). We were also able to steer the centroid of activation towards the direction of any of the electrodes of the group by applying a greater charge to that electrode, but the movement in the centroid was not found to be significant. Significance. The results suggest that current steering is possible in two dimensions between up to at least six electrodes, indicating it may be possible to increase the number of percepts in patients without increasing the number

  4. Cochlear pathology following reimplantation of a multichannel scala tympani electrode array in the macaque.

    Science.gov (United States)

    Shepherd, R K; Clark, G M; Xu, S A; Pyman, B C

    1995-03-01

    The histopathologic consequence of removing and reimplanting intracochlear electrode arrays on residual auditory nerve fibers is an important issue when evaluating the safety of cochlear prostheses. The authors have examined this issue by implanting multichannel intracochlear electrodes in macaque monkeys. Macaques were selected because of the similarity of the surgical technique used to insert electrodes into the cochlea compared to that in humans, in particular the ability to insert the arrays into the upper basal turn. Five macaques were bilaterally implanted with the Melbourne/Cochlear banded electrode array. Following a minimum implant period of 5 months, the electrode array on one side of each animal was removed and another immediately implanted. The animals were sacrificed a minimum of 5 months following the reinsertion procedure, and the cochleas prepared for histopathologic analysis. Long-term implantation of the electrode resulted in a relatively mild tissue response within the cochlea. Results also showed that inner and outer hair cell survival, although significantly reduced adjacent to the array, was normal in 8 of the 10 cochleas apicalward. Moreover, the electrode reinsertion procedure did not appear to adversely affect this apical hair cell population. Significant new bone formation was frequently observed in both control and reimplanted cochleas close to the electrode fenestration site and was associated with trauma to the endosteum and/or the introduction of bone chips into the cochlea at the time of surgery. Electrode insertion trauma, involving the osseous spiral lamina or basilar membrane, was more commonly observed in reimplanted cochleas. This damage was usually restricted to the lower basal turn and resulted in a more extensive ganglion cell loss. Finally, in a number of cochleas part of the electrode array was located within the scala media or scala vestibuli. These electrodes did not appear to evoke a more extensive tissue response or

  5. A foldable electrode array for 3D recording of deep-seated abnormal brain cavities

    Science.gov (United States)

    Kil, Dries; De Vloo, Philippe; Fierens, Guy; Ceyssens, Frederik; Hunyadi, Borbála; Bertrand, Alexander; Nuttin, Bart; Puers, Robert

    2018-06-01

    Objective. This study describes the design and microfabrication of a foldable thin-film neural implant and investigates its suitability for electrical recording of deep-lying brain cavity walls. Approach. A new type of foldable neural electrode array is presented, which can be inserted through a cannula. The microfabricated electrode is specifically designed for electrical recording of the cavity wall of thalamic lesions resulting from stroke. The proof-of-concept is demonstrated by measurements in rat brain cavities. On implantation, the electrode array unfolds in the brain cavity, contacting the cavity walls and allowing recording at multiple anatomical locations. A three-layer microfabrication process based on UV-lithography and Reactive Ion Etching is described. Electrochemical characterization of the electrode is performed in addition to an in vivo experiment in which the implantation procedure and the unfolding of the electrode are tested and visualized. Main results. Electrochemical characterization validated the suitability of the electrode for in vivo use. CT imaging confirmed the unfolding of the electrode in the brain cavity and analysis of recorded local field potentials showed the ability to record neural signals of biological origin. Significance. The conducted research confirms that it is possible to record neural activity from the inside wall of brain cavities at various anatomical locations after a single implantation procedure. This opens up possibilities towards research of abnormal brain cavities and the clinical conditions associated with them, such as central post-stroke pain.

  6. The Effect of Radiation on Complication Rates and Patient Satisfaction in Breast Reconstruction using Temporary Tissue Expanders and Permanent Implants.

    Science.gov (United States)

    Anker, Christopher J; Hymas, Richard V; Ahluwalia, Ravinder; Kokeny, Kristine E; Avizonis, Vilija; Boucher, Kenneth M; Neumayer, Leigh A; Agarwal, Jayant P

    2015-01-01

    The optimal method of reconstruction following mastectomy for breast cancer patients receiving radiation therapy (RT) is controversial. This study evaluated patient satisfaction and complication rates among patients who received implant-based breast reconstruction. The specific treatment algorithm analyzed included patients receiving mastectomy and immediate temporary tissue expander (TE), followed by placement of a permanent breast implant (PI). If indicated, RT was delivered to the fully expanded TE. Records of 218 consecutive patients with 222 invasive (85%) or in situ (15%) breast lesions from the Salt Lake City region treated between 1998 and 2009 were retrospectively reviewed, 28% of whom received RT. Median RT dose was 50.4 Gy, and 41% received a scar boost at a median dose of 10 Gy. Kaplan-Meier analyses were performed to evaluate the cumulative incidence of surgical complications, including permanent PI removal. Risk factors associated with surgical events were analyzed. To evaluate cosmetic results and patient satisfaction, an anonymous survey was administered. Mean follow-up was 44 months (range 6-144). Actuarial 5-year PI removal rates for non-RT and RT patients were 4% and 22%, respectively. On multivariate analysis (MVA), the only factor associated with PI removal was RT (p = 0.009). Surveys were returned describing the outcomes of 149 breasts. For the non-RT and RT groups, those who rated their breast appearance as good or better were 63% versus 62%, respectively. Under 1/3 of each group was dissatisfied with their reconstruction. RT did not significantly affect patient satisfaction scores, but on MVA RT was the only factor associated with increased PI removal. This reconstruction technique may be considered an acceptable option even if RT is needed, but the increased complication risk with RT must be recognized. © 2015 Wiley Periodicals, Inc.

  7. Effect of right ventricular electrode location (outflow tract vs. apex) on mechanical Ventricular synchrony in patients that underwent pacemaker implant therapy

    International Nuclear Information System (INIS)

    Rincon, Oscar S; Saenz, Luis C; Salazar, Gabriel; Hernandez, Edgar

    2008-01-01

    Objective: to assess in depth the effect of ventricular stimulation from the right ventricular outflow tract and the apex on mechanical ventricular synchrony. Materials And Methods: cohort analytical study. 20 patients with indication of definitive pacemaker indication underwent trans thoracic echocardiogram before and after pacemaker implant with electrode implantation in the right ventricular outflow tract and in the apex (10 patients in each group). There was no structural cardiopathy, ejection fraction was ? 50%, QRS and AV conduction were normal. Mechanical ventricular asynchrony (M mode and tissue doppler) and implant and device parameters were evaluated. Statistical Analysis: results are given as mean values, standard deviation or percentages.Continuous variables were compared using Chi-square test and ANOVA. A p <0.05 value was considered statistically significant. Results: in five patients (25%) a pre-implant ventricular asynchrony was found; in seven (70%) ventricular asynchrony post-implant in the right ventricle outflow tract and in 5 (50%) in the apex. Mean interventricular pot-implant delay was 21,6 ms in the right ventricular outflow tract and 11,5 ms in the apex (p = 0,8); mean septal to lateral wall delay was 73 ms in the right ventricular outflow tract and 26 ms in the apex (p = 0,8). QRS post-implant delay was 134 ms in the right ventricular outflow tract and 140 ms in the apex (p = 0,1). No differences between implant parameters and device programming were found. Conclusions: presence of ventricular asynchrony was evidenced in patients with normal QRS and structurally healthy heart. Ventricular stimulation with pacemaker from the apex or the right ventricular outflow tract suggests acute ventricular asynchrony at least in 60% of the cases, without statistically significant difference between both groups.

  8. Long-Term Retrievability of IVC Filters: Should We Abandon Permanent Devices?

    International Nuclear Information System (INIS)

    Berczi, V.; Bottomley, J. R.; Thomas, S. M.; Taneja, S.; Gaines, P. A.; Cleveland, T. J.

    2007-01-01

    Thromboembolic disease produces a considerable disease burden, with death from pulmonary embolism in the UK alone estimated at 30,000-40,000 per year. Whilst it is unproven whether filters actually improve longevity, the morbidity and mortality associated with thromboembolic disease in the presence of contraindications to anticoagulation is high. Thus complications associated with filter insertion, and whilst they remain in situ, must be balanced against the alternatives. Permanent filters remain in situ for the remainder of the patient's life and any complications from the filters are of significant concern. Filters that are not permanent are therefore attractive in these circumstances. Retrievable filters, to avoid or decrease long-term filter complications, appear to be a significant advance in the prevention of pulmonary embolism. In this review, we discuss the safety and effectiveness of both permanent and retrievable filters as well as the retrievability of retrievable inferior vena cava (IVC) filters, to explore whether the use of permanent IVC filters can be abandoned in favor of retrievable filters. Currently four types of retrievable filters are available: the Recovery filter (Bard Peripheral Vascular, Tempe, AZ, USA), the Guenther Tulip filter (Cook, Bloomington, IN, USA), the OptEase Filter (Cordis, Roden, The Netherlands), and the ALN filter (ALN Implants Chirurgicaux, Ghisonaccia, France). Efficacy and safety data for retrievable filters are as yet based on small series, with a total number of fewer than 1,000 insertions, and follow-up is mostly short term. Current long-term data are poor and insufficient to warrant the long-term implantation of these devices into humans. The case of fractured wire from a Recovery filter that migrated to the heart causing pericardial tamponade requiring open heart surgery is a reminder that any new endovascular device remaining in situ in the long term may produce unexpected problems. We should also bear in mind that

  9. Bilateral cochlear implants in infants: a new approach--Nucleus Hybrid S12 project.

    Science.gov (United States)

    Gantz, Bruce J; Dunn, Camille C; Walker, Elizabeth A; Kenworthy, Maura; Van Voorst, Tanya; Tomblin, Bruce; Turner, Chris

    2010-10-01

    The purpose of this feasibility study was to evaluate whether the use of a shorter-length cochlear implant (10 mm) on one ear and a standard electrode (24 mm) on the contralateral ear is a viable bilateral option for children with profound bilateral sensorineural hearing loss. A secondary purpose of this study was to determine whether the ear with the shorter-length electrode performs similarly to the standard-length electrode. Our goal was to provide an option of electrical stimulation that theoretically might preserve the structures of the scala media and organ of Corti. The study is being conducted as a repeated-measure, single-subject experiment. University of Iowa-Department of Otolaryngology. Eight pediatric patients with profound bilateral sensorineural hearing loss between the ages of 12 and 24 months. Nucleus Hybrid S12 10-mm electrode and a Nucleus Freedom implant in the contralateral ear. The Infant-Toddler Meaningful Auditory Integration Scale (IT-MAIS) parent questionnaire, Early Speech Perception, Glendonald Auditory Screening Procedure word test, and Children's Vowel tests will be used to evaluate speech perception and the Minnesota Child Development Inventory and Preschool Language Scales 3 test will be used to evaluate language growth. Preliminary results for 8 children have been collected before and after the operation using the IT-MAIS. All 3 children showed incremental improvements in their IT-MAIS scores overtime. Early Speech Perception, Glendonald Auditory Screening Procedure word test, and Children's Vowel word perception results indicated no difference between the individual ears for the 2 children tested. Performance compared with age-matched children implanted with standard bilateral cochlear implants showed similar results to the children implanted with Nucleus Hybrid S12 10-mm electrode and a Nucleus Freedom implant in contralateral ears. The use of a shorter-length cochlear implant on one ear and a standard-length electrode on the

  10. In vivo dosimetry using a linear Mosfet-array dosimeter to determine the urethra dose in 125I permanent prostate implants.

    Science.gov (United States)

    Bloemen-van Gurp, Esther J; Murrer, Lars H P; Haanstra, Björk K C; van Gils, Francis C J M; Dekker, Andre L A J; Mijnheer, Ben J; Lambin, Philippe

    2009-01-01

    In vivo dosimetry during brachytherapy of the prostate with (125)I seeds is challenging because of the high dose gradients and low photon energies involved. We present the results of a study using metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters to evaluate the dose in the urethra after a permanent prostate implantation procedure. Phantom measurements were made to validate the measurement technique, determine the measurement accuracy, and define action levels for clinical measurements. Patient measurements were performed with a MOSFET array in the urinary catheter immediately after the implantation procedure. A CT scan was performed, and dose values, calculated by the treatment planning system, were compared to in vivo dose values measured with MOSFET dosimeters. Corrections for temperature dependence of the MOSFET array response and photon attenuation in the catheter on the in vivo dose values are necessary. The overall uncertainty in the measurement procedure, determined in a simulation experiment, is 8.0% (1 SD). In vivo dose values were obtained for 17 patients. In the high-dose region (> 100 Gy), calculated and measured dose values agreed within 1.7% +/- 10.7% (1 SD). In the low-dose region outside the prostate (MOSFET detectors are suitable for in vivo dosimetry during (125)I brachytherapy of prostate cancer. An action level of +/- 16% (2 SD) for detection of errors in the implantation procedure is achievable after validation of the detector system and measurement conditions.

  11. Brachytherapy optimization using radiobiological-based planning for high dose rate and permanent implants for prostate cancer treatment

    Science.gov (United States)

    Seeley, Kaelyn; Cunha, J. Adam; Hong, Tae Min

    2017-01-01

    We discuss an improvement in brachytherapy--a prostate cancer treatment method that directly places radioactive seeds inside target cancerous regions--by optimizing the current standard for delivering dose. Currently, the seeds' spatiotemporal placement is determined by optimizing the dose based on a set of physical, user-defined constraints. One particular approach is the ``inverse planning'' algorithms that allow for tightly fit isodose lines around the target volumes in order to reduce dose to the patient's organs at risk. However, these dose distributions are typically computed assuming the same biological response to radiation for different types of tissues. In our work, we consider radiobiological parameters to account for the differences in the individual sensitivities and responses to radiation for tissues surrounding the target. Among the benefits are a more accurate toxicity rate and more coverage to target regions for planning high-dose-rate treatments as well as permanent implants.

  12. Rodent model for assessing the long term safety and performance of peripheral nerve recording electrodes

    Science.gov (United States)

    Vasudevan, Srikanth; Patel, Kunal; Welle, Cristin

    2017-02-01

    Objective. In the US alone, there are approximately 185 000 cases of limb amputation annually, which can reduce the quality of life for those individuals. Current prosthesis technology could be improved by access to signals from the nervous system for intuitive prosthesis control. After amputation, residual peripheral nerves continue to convey motor signals and electrical stimulation of these nerves can elicit sensory percepts. However, current technology for extracting information directly from peripheral nerves has limited chronic reliability, and novel approaches must be vetted to ensure safe long-term use. The present study aims to optimize methods to establish a test platform using rodent model to assess the long term safety and performance of electrode interfaces implanted in the peripheral nerves. Approach. Floating Microelectrode Arrays (FMA, Microprobes for Life Sciences) were implanted into the rodent sciatic nerve. Weekly in vivo recordings and impedance measurements were performed in animals to assess performance and physical integrity of electrodes. Motor (walking track analysis) and sensory (Von Frey) function tests were used to assess change in nerve function due to the implant. Following the terminal recording session, the nerve was explanted and the health of axons, myelin and surrounding tissues were assessed using immunohistochemistry (IHC). The explanted electrodes were visualized under high magnification using scanning electrode microscopy (SEM) to observe any physical damage. Main results. Recordings of axonal action potentials demonstrated notable session-to-session variability. Impedance of the electrodes increased upon implantation and displayed relative stability until electrode failure. Initial deficits in motor function recovered by 2 weeks, while sensory deficits persisted through 6 weeks of assessment. The primary cause of failure was identified as lead wire breakage in all of animals. IHC indicated myelinated and unmyelinated axons

  13. Optimal implantation depth and adherence to guidelines on permanent pacing to improve the results of transcatheter aortic valve replacement with the medtronic corevalve system: The CoreValve prospective, international, post-market ADVANCE-II study

    NARCIS (Netherlands)

    A.S. Petronio (Anna); J.-M. Sinning (Jan-Malte); N.M. van Mieghem (Nicolas); G. Zucchelli (Giulio); G. Nickenig (Georg); R. Bekeredjian (Raffi); J. Bosmans (Johan); F. Bedogni (Francesco); M. Branny (Marian); K. Stangl (Karl); J. Kovac (Jan); M. Schiltgen (Molly); S. Kraus (Stacia); P.P.T. de Jaegere (Peter)

    2015-01-01

    textabstractObjectives The aim of the CoreValve prospective, international, post-market ADVANCE-II study was to define the rates of conduction disturbances and permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement with the Medtronic CoreValve System (Minneapolis,

  14. Venous Obstruction Following Pacemaker or Implantable Cardioverter-Defibrillator Implantation, Mini Review

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Akbarzadeh

    2016-08-01

    Full Text Available Venous obstruction is relatively frequent following permanent pacemaker or implantable cardioverter-defibrillator (ICD implantation. However, most of them are asymptomatic. Although the exact risk factor for this complication is not known, number of leads, heart failure and infection may prone the patient to this complication. The goal standard for detection of vein stenosis is venography; however, ultrasound sonography has an acceptable accuracy. Anticoagulant therapy may be considered for symptomatic patients. For device upgrading, non-functional leads removal, venoplasty and rarely surgical treatment may be indicated.

  15. Radiation exposure after permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Cattani, Federica; Vavassori, Andrea; Polo, Alfredo; Rondi, Elena; Cambria, Raffaella; Orecchia, Roberto; Tosi, Giampiero

    2006-01-01

    Background and purpose: Limited information is available on the true radiation exposure and associated risks for the relatives of the patients submitted to prostate brachytherapy with permanent implant of radioactive sources and for any other people coming into contact with them. In order to provide appropriate information, we analyzed the radiation exposure data from 216 prostate cancer patients who underwent 125 I or 103 Pd implants at the European Institute of Oncology of Milan, Italy. Patients and methods: Between October 1999 and October 2004, 216 patients with low risk prostate carcinoma were treated with 125 I (200 patients) or 103 Pd (16 patients) permanent seed implantation. One day after the procedure, radiation exposure measurements around the patients were performed using an ionization chamber survey meter (Victoreen RPO-50) calibrated in dose rate at an accredited calibration center (calibration Centre SIT 104). Results: The mean dose rate at the posterior skin surface (gluteal region) following 125 I implants was 41.3 μSv/h (range: 6.2-99.4 μSv/h) and following 103 Pd implants was 18.9 μSv/h (range 5.0-37.3 μSv/h). The dose rate at 50 cm from the skin decreased to the mean value of 6.4 μSv/h for the 125 I implants and to the mean value of 1.7 μSv/h for the 103 Pd implants. Total times required to reach the annual dose limit (1 mSv/year) recommended for the general population by the European Directive 96/29/Euratom and by the Italian law (Decreto Legislativo 241/2000) at a distance of 50 cm from the posterior skin surface of the implanted patient would be 7.7 and 21.6 days for 125 I and for 103 Pd. Good correlation between the measured dose rates and both the total implanted activity and the distance between the most posteriorly implanted seed and the skin surface of the patients was found. Conclusions: Our data show that the dose rates at 50 cm away from the prostate brachytherapy patients are very low and that the doses possibly absorbed by the

  16. Technological innovations in implants used for pain therapies.

    Science.gov (United States)

    Shaw, Andrew; Sharma, Mayur; Deogaonkar, Milind; Rezai, Ali

    2014-10-01

    The field of pain management has experienced tremendous growth in implantable therapies secondary to the innovations of bioengineers, implanters, and industry. Every aspect of neuromodulation is amenable to innovation from implanting devices to anchors, electrodes, programming, and even patient programmers. Patients with previously refractory neuropathic pain syndromes have new and effective pain management strategies that are a direct result of innovations in implantable devices. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Perceptual Interactions Between Electrodes Using Focused and Monopolar Cochlear Stimulation

    DEFF Research Database (Denmark)

    Marozeau, Jeremy; McDermott, Hugh J.; Swanson, Brett A.

    2015-01-01

    -matched sequential and simultaneous stimuli composed of 2 spatially separated pulse trains was measured as function of the electrode separation. Results indicated a strong current-summation interaction for simultaneous stimuli in the MP mode for separations up to at least 4.8 mm. No significant interaction was found......In today’s cochlear implant (CI) systems, the monopolar (MP) electrode configuration is the most commonly used stimulation mode, requiring only a single current source. However, with an implant that will allow simultaneous activation of multiple independent current sources, it is possible...

  18. Sirviendo a los estudiantes sordos que tienen Los implantes cocleares. Hoja de consejos de PEPNet (Serving Deaf Students Who Have Cochlear Implants. PEPNet Tipsheet)

    Science.gov (United States)

    Clark, Catherine

    2010-01-01

    This version of "Serving Deaf Students Who Have Cochlear Implants. PEPNet Tipsheet," written in Spanish, describes how cochlear implants (CIs) work. CIs are complex electronic devices surgically implanted under the skin behind the ear. These devices utilize electrodes placed in the inner ear (the cochlea) to stimulate the auditory nerve of…

  19. Use of brachytherapy with permanent implants of iodine-125 in localized prostate cancer

    International Nuclear Information System (INIS)

    Bladou, F.; Serment, G.; Salem, N.; Simonian, M.; Rosello, R.; Ternier, F.

    2002-01-01

    Approximately 15,000 cases of early stage prostate cancer T1 and T2 are diagnosed every year in France by testing for PSA and performing prostatic biopsies. The treatment of these localized forms is based in most cases on radical prostatectomy or nn external beam radiotherapy. Although the ontological results obtained by these two therapeutic methods are satisfactory and equivalent in the long term, the side effects can be important. For a number of years, trans-perineal brachytherapy using permanent implants of iodine -125 or palladium-103 has proved itself as an alternative therapy with equivalent medium to long-term results. The low urinary, digestive and sexual side effects of prostate brachytherapy are important reasons for the enthusiasm among patients and the medical community for this therapy and the growing number of applications and centres which practice it. In September 1998 we started the prostate brachytherapy programmes- in Marseilles with close collaboration between the department of urology of the Hopital Salvator, and the departments of radiotherapy, medical imaging and medical physics of the Institut Paoli-Calmettes. To date, around 250 patients with localized adenocarcinoma of the prostate have benefited from this alternative therapy in our centre. Preliminary results, with a 3 year-follow-up, are comparable to results published in the literature by pioneer teams. (authors)

  20. Analysis of a five year experience of permanent pacemaker ...

    African Journals Online (AJOL)

    Introduction: Permanent pacemaker implantation is available in Nigeria. There is however no national registry or framework for pacemaker data collection. A pacemaker database has been developed in our institution and the results are analyzed in this study. Methods: The study period was between January 2008 and ...

  1. COMMUNICATION: Toward a self-deploying shape memory polymer neuronal electrode

    Science.gov (United States)

    Sharp, Andrew A.; Panchawagh, Hrishikesh V.; Ortega, Alicia; Artale, Ryan; Richardson-Burns, Sarah; Finch, Dudley S.; Gall, Ken; Mahajan, Roop L.; Restrepo, Diego

    2006-12-01

    The widespread application of neuronal probes for chronic recording of brain activity and functional stimulation has been slow to develop partially due to long-term biocompatibility problems with existing metallic and ceramic probes and the tissue damage caused during probe insertion. Stiff probes are easily inserted into soft brain tissue but cause astrocytic scars that become insulating sheaths between electrodes and neurons. In this communication, we explore the feasibility of a new approach to the composition and implantation of chronic electrode arrays. We demonstrate that softer polymer-based probes can be inserted into the olfactory bulb of a mouse and that slow insertion of the probes reduces astrocytic scarring. We further present the development of a micromachined shape memory polymer probe, which provides a vehicle to self-deploy an electrode at suitably slow rates and which can provide sufficient force to penetrate the brain. The deployment rate and composition of shape memory polymer probes can be tailored by polymer chemistry and actuator design. We conclude that it is feasible to fabricate shape memory polymer-based electrodes that would slowly self-implant compliant conductors into the brain, and both decrease initial trauma resulting from implantation and enhance long-term biocompatibility for long-term neuronal measurement and stimulation.

  2. Investigation of the effect of cochlear implant electrode length on speech comprehension in quiet and noise compared with the results with users of electro-acoustic-stimulation, a retrospective analysis.

    Science.gov (United States)

    Büchner, Andreas; Illg, Angelika; Majdani, Omid; Lenarz, Thomas

    2017-01-01

    This investigation evaluated the effect of cochlear implant (CI) electrode length on speech comprehension in quiet and noise and compare the results with those of EAS users. 91 adults with some degree of residual hearing were implanted with a FLEX20, FLEX24, or FLEX28 electrode. Some subjects were postoperative electric-acoustic-stimulation (EAS) users; the other subjects were in the groups of electric stimulation-only (ES-only). Speech perception was tested in quiet and noise at 3 and 6 months of ES or EAS use. Speech comprehension results were analyzed and correlated to electrode length. While the FLEX20 ES and FLEX24 ES groups were still in their learning phase between the 3 to 6 months interval, the FLEX28 ES group was already reaching a performance plateau at the three months appointment yielding remarkably high test scores. EAS subjects using FLEX20 or FLEX24 electrodes outscored ES-only subjects with the same short electrodes on all 3 tests at each interval, reaching significance with FLEX20 ES and FLEX24 ES subjects on all 3 tests at the 3-months interval and on 2 tests at the 6- months interval. Amongst ES-only subjects at the 3- months interval, FLEX28 ES subjects significantly outscored FLEX20 ES subjects on all 3 tests and the FLEX24 ES subjects on 2 tests. At the-6 months interval, FLEX28 ES subjects still exceeded the other ES-only subjects although the difference did not reach significance. Among ES-only users, the FLEX28 ES users had the best speech comprehension scores, at the 3- months appointment and tendentially at the 6 months appointment. EAS users showed significantly better speech comprehension results compared to ES-only users with the same short electrodes.

  3. Evaluation of high-perimeter electrode designs for deep brain stimulation

    Science.gov (United States)

    Howell, Bryan; Grill, Warren M.

    2014-08-01

    Objective. Deep brain stimulation (DBS) is an effective treatment for movement disorders and a promising therapy for treating epilepsy and psychiatric disorders. Despite its clinical success, complications including infections and mis-programing following surgical replacement of the battery-powered implantable pulse generator adversely impact the safety profile of this therapy. We sought to decrease power consumption and extend battery life by modifying the electrode geometry to increase stimulation efficiency. The specific goal of this study was to determine whether electrode contact perimeter or area had a greater effect on increasing stimulation efficiency. Approach. Finite-element method (FEM) models of eight prototype electrode designs were used to calculate the electrode access resistance, and the FEM models were coupled with cable models of passing axons to quantify stimulation efficiency. We also measured in vitro the electrical properties of the prototype electrode designs and measured in vivo the stimulation efficiency following acute implantation in anesthetized cats. Main results. Area had a greater effect than perimeter on altering the electrode access resistance; electrode (access or dynamic) resistance alone did not predict stimulation efficiency because efficiency was dependent on the shape of the potential distribution in the tissue; and, quantitative assessment of stimulation efficiency required consideration of the effects of the electrode-tissue interface impedance. Significance. These results advance understanding of the features of electrode geometry that are important for designing the next generation of efficient DBS electrodes.

  4. Diagnostic Imaging for Dental Implant Therapy

    Directory of Open Access Journals (Sweden)

    Aishwarya Nagarajan

    2014-01-01

    Full Text Available Dental implant is a device made of alloplastic (foreign material implanted into the jaw bone beneath the mucosal layer to support a fixed or removable dental prosthesis. Dental implants are gaining immense popularity and wide acceptance because they not only replace lost teeth but also provide permanent restorations that do not interfere with oral function or speech or compromise the self-esteem of a patient. Appropriate treatment planning for replacement of lost teeth is required and imaging plays a pivotal role to ensure a satisfactory outcome. The development of pre-surgical imaging techniques and surgical templates helps the dentist place the implants with relative ease. This article focuses on various types of imaging modalities that have a pivotal role in implant therapy.

  5. Bilateral Cochlear Implants in Infants: A New Approach—Nucleus Hybrid S12 Project

    Science.gov (United States)

    Gantz, Bruce J.; Dunn, Camille C.; Walker, Elizabeth A.; Kenworthy, Maura; Van Voorst, Tanya; Tomblin, Bruce; Turner, Chris

    2010-01-01

    Objective The purpose of this feasibility study was to evaluate whether the use of a shorter-length cochlear implant (10 mm) on one ear and a standard electrode (24 mm) on the contralateral ear is a viable bilateral option for children with profound bilateral sensorineural hearing loss. A secondary purpose of this study was to determine whether the ear with the shorter-length electrode performs similarly to the standard-length electrode. Our goal was to provide an option of electrical stimulation that theoretically might preserve the structures of the scala media and organ of Corti. Study Design The study is being conducted as a repeated-measure, single-subject experiment. Setting University of Iowa—Department of Otolaryngology. Patients Eight pediatric patients with profound bilateral sensorineural hearing loss between the ages of 12 and 24 months. Interventions Nucleus Hybrid S12 10-mm electrode and a Nucleus Freedom implant in the contralateral ear. Main Outcome Measures The Infant-Toddler Meaningful Auditory Integration Scale (IT-MAIS) parent questionnaire, Early Speech Perception, Glendonald Auditory Screening Procedure word test, and Children’s Vowel tests will be used to evaluate speech perception and the Minnesota Child Development Inventory and Preschool Language Scales 3 test will be used to evaluate language growth. Results Preliminary results for 8 children have been collected before and after the operation using the IT-MAIS. All 3 children showed incremental improvements in their IT-MAIS scores overtime. Early Speech Perception, Glendonald Auditory Screening Procedure word test, and Children’s Vowel word perception results indicated no difference between the individual ears for the 2 children tested. Performance compared with age-matched children implanted with standard bilateral cochlear implants showed similar results to the children implanted with Nucleus Hybrid S12 10-mm electrode and a Nucleus Freedom implant in contralateral ears

  6. A Respiratory Marker Derived From Left Vagus Nerve Signals Recorded With Implantable Cuff Electrodes.

    Science.gov (United States)

    Sevcencu, Cristian; Nielsen, Thomas N; Kjaergaard, Benedict; Struijk, Johannes J

    2018-04-01

    Left vagus nerve (LVN) stimulation (LVNS) has been tested for lowering the blood pressure (BP) in patients with resistant hypertension (RH). Whereas, closed-loop LVNS (CL-LVNS) driven by a BP marker may be superior to open-loop LVNS, there are situations (e.g., exercising) when hypertension is normal. Therefore, an ideal anti-RH CL-LVNS system requires a variable to avoid stimulation in such conditions, for example, a respiratory marker ideally extracted from the LVN. As the LVN conducts respiratory signals, this study aimed to investigate if such signals can be recorded using implantable means and if a marker to monitor respiration could be derived from such recordings. The experiments were performed in 14 anesthetized pigs. Five pigs were subjected to changes of the respiratory frequency and nine to changes of the respiratory volume. The LVN electroneurogram (VENG) was recorded using two cuff electrodes and the respiratory cycles (RC) using a pressure transducer. To separate the afferent and efferent VENGs, vagotomy was performed between the cuffs in the first group of pigs. The VENG was squared to derive respiration-related neural profiles (RnPs) and their correlation with the RCs was investigated in regard to timing and magnitude parameters derived from the two waveforms. The RnPs were morphologically similar with the RCs and the average RnPs represented accurate copies of the average RCs. Consequently, the lung inflation/deflation RC and RnP components had the same duration, the respiratory frequency changes affected in the same way both waveforms and the RnP amplitude increased linearly with the lung inflation in all tested pigs (R 2 values between 0.85 and 0.99). The RnPs comprise information regarding the timing and magnitude of the respiratory parameters. As those LVN profiles were derived using implantable means, this study indicates that the RnPs could serve as respiratory markers in implantable systems. © 2017 International Neuromodulation Society.

  7. Enhanced control of electrochemical response in metallic materials in neural stimulation electrode applications

    Energy Technology Data Exchange (ETDEWEB)

    Watkins, K.G.; Steen, W.M.; Manna, I. [Univ. of Liverpool (United Kingdom)] [and others

    1996-12-31

    New means have been investigated for the production of electrode devices (stimulation electrodes) which could be implanted in the human body in order to control pain, activate paralysed limbs or provide electrode arrays for cochlear implants for the deaf or for the relief of tinitus. To achieve this ion implantation and laser materials processing techniques were employed. Ir was ion implanted in Ti-6Al-4V alloy and the surface subsequently enriched in the noble metal by dissolution in sulphuric acid. For laser materials processing techniques, investigation has been carried out on the laser cladding and laser alloying of Ir in Ti wire. A particular aim has been the determination of conditions required for the formation of a two phase Ir, Ir-rich, and Ti-rich microstructure which would enable subsequent removal of the non-noble phase to leave a highly porous noble metal with large real surface area and hence improved charge carrying capacity compared with conventional non porous electrodes. Evaluation of the materials produced has been carried out using repetitive cyclic voltammetry, amongst other techniques. For laser alloyed Ir on Ti wire, it has been found that differences in the melting point and density of the materials makes control of the cladding or alloying process difficult. Investigation of laser process parameters for the control of alloying and cladding in this system was carried out and a set of conditions for the successful production of two phase Ir-rich and Ti-rich components in a coating layer with strong metallurgical bonding to the Ti alloy substrate was derived. The laser processed material displays excellent potential for further development in providing stimulation electrodes with the current carrying capacity of Ir but in a form which is malleable and hence capable of formation into smaller electrodes with improved spatial resolution compared with presently employed electrodes.

  8. [Cochlear implantation through the middle fossa approach].

    Science.gov (United States)

    Szyfter, W; Colletti, V; Pruszewicz, A; Kopeć, T; Szymiec, E; Kawczyński, M; Karlik, M

    2001-01-01

    The inner part of cochlear implant is inserted into inner ear during surgery through mastoid and middle ear. It is a classical method, used in the majority cochlear centers in the world. This is not a suitable method in case of chronic otitis media and middle ear malformation. In these cases Colletti proposed the middle fossa approach and cochlear implant insertion omitting middle ear structures. In patient with bilateral chronic otitis media underwent a few ears operations without obtaining dry postoperative cavity. Cochlear implantation through the middle fossa approach was performed in this patient. The bone fenster was cut, temporal lobe was bent and petrosus pyramid upper surface was exposed. When the superficial petrosal greater nerve, facial nerve and arcuate eminence were localised, the cochlear was open in the basal turn and electrode were inserted. The patient achieves good results in the postoperative speech rehabilitation. It confirmed Colletti tesis that deeper electrode insertion in the cochlear implantation through the middle fossa approach enable use of low and middle frequencies, which are very important in speech understanding.

  9. Fabrication of an Implantable Micro-pressure Sensor to Measure Deviation Within the Cochlea

    Directory of Open Access Journals (Sweden)

    Leonardo Perez

    2013-06-01

    Full Text Available The Cochlear Implant is broadly worn by people with deep hearing damage. This device makes up an electrode array to electrically stimulate the auditory nerves. When the electrode is implanted into the inner ear by surgery, the scala tympani is ill-treated due to the strong pressure applied on the internal ear structures. To minimize this intra-cochlear trauma, it is proposed to fabricate a micro pressure-sensor and built it in the electrode array, in such a way that the pressure applied by the electrode is measured. This work selected the MEMS SU-8 Fabry-Perot interferometer-based pressure sensor. This paper describes the sensor fabrication process carried out, and explains how to integrate this sensor with the electrode array.

  10. Enhanced osseous implant fixation with strontium-substituted bioactive glass coating

    NARCIS (Netherlands)

    Newman, S.D.; Lotfibakhshaiesh, N.; O'Donnell, M.; Walboomers, X.F.; Horwood, N.; Jansen, J.A.; Amis, A.A.; Cobb, J.P.; Stevens, M.M.

    2014-01-01

    The use of endosseous implants is firmly established in skeletal reconstructive surgery, with rapid and permanent fixation of prostheses being a highly desirable feature. Implant coatings composed of hydroxyapatite (HA) have become the standard and have been used with some success in prolonging the

  11. A touch probe method of operating an implantable RFID tag for orthopedic implant identification.

    Science.gov (United States)

    Liu, Xiaoyu; Berger, J Lee; Ogirala, Ajay; Mickle, Marlin H

    2013-06-01

    The major problem in operating an implantable radio-frequency identification (RFID) tag embedded on an orthopedic implant is low efficiency because of metallic interference. To improve the efficiency, this paper proposes a method of operating an implantable passive RFID tag using a touch probe at 13.56 MHz. This technology relies on the electric field interaction between two pairs of electrodes, one being a part of the touch probe placed on the surface of tissue and the other being a part of the tag installed under the tissue. Compared with using a conventional RFID antenna such as a loop antenna, this method has a better performance in the near field operation range to reduce interference with the orthopedic implant. Properly matching the touch probe and the tag to the tissue and the implant reduces signal attenuation and increases the overall system efficiency. The experiments have shown that this method has a great performance in the near field transcutaneous operation and can be used for orthopedic implant identification.

  12. Fabrication and characterization of implantable and flexible nerve cuff electrodes with Pt, Ir and IrOx films deposited by RF sputtering

    International Nuclear Information System (INIS)

    Lee, Soo Hyun; Jung, Jung Hwan; Chae, Youn Mee; Kang, Ji Yoon; Suh, Jun-Kyo Francis

    2010-01-01

    This paper presents the fabrication and characterization of implantable and flexible nerve cuff electrodes for neural interfaces using the conventional BioMEMS technique. In order to fabricate a flexible nerve electrode, polyimide (PI) was chosen as the substrate material. Then, nerve electrodes were thermally re-formed in a cuff shape so as to increase the area in which the charges were transferred to the nerve. Platinum (Pt), iridium (Ir) and iridium oxide (IrO x ) films, which were to serve as conducting materials for the nerve electrodes, were deposited at different working pressures by RF magnetron sputtering. The electrochemical properties of the deposited films were characterized by electrochemical impedance spectroscopy (EIS). The charge delivery capacities of the films were recorded and calculated by cyclic voltammetry (CV). The deposited films of Pt, Ir and IrO x have strong differences in electrochemical properties, which depend on the working pressure of sputter. Each film deposited at 30 mTorr of working pressure shows the highest value of charge delivery capacity (CDC). For the IrO x films, the electrochemical properties were strongly affected by the working pressure as well as the Ar:O 2 gas ratio. The IrO x film deposited with an Ar:O 2 gas ratio of 8:1 showed the highest CDC of 59.5 mC cm −2 , which was about five times higher than that of films deposited with a 1:1 gas ratio.

  13. Fabrication and surface-modification of implantable microprobes for neuroscience studies

    International Nuclear Information System (INIS)

    Cao, H; Nguyen, C M; Chiao, J C

    2012-01-01

    In this work implantable micro-probes for central nervous system (CNS) studies were developed on silicon and polyimide substrates. The probes which contained micro-electrode arrays with different surface modifications were designed for implantation in the CNS. The electrode surfaces were modified with nano-scale structures that could greatly increase the active surface area in order to enhance the electrochemical current outputs while maintaining micro-scale dimensions of the electrodes and probes. The electrodes were made of gold or platinum, and designed with different sizes. The silicon probes were modified by silicon nanowires fabricated with the vapor–liquid–solid mechanism at high temperatures. With polyimide substrates, the nanostructure modification was carried out by applying concentrated gold or silver colloid solutions onto the micro-electrodes at room temperature. The surfaces of electrodes before and after modification were observed by scanning electron microscopy. The silicon nanowire-modified surface was characterized by cyclic voltammetry. Experiments were carried out to investigate the improvement in sensing performance. The modified electrodes were tested with H 2 O 2 , electrochemical L-glutamate and dopamine. Comparisons between electrodes with and without nanostructure modification were conducted showing that the modifications have enhanced the signal outputs of the electrochemical neurotransmitter sensors

  14. Fabrication and surface-modification of implantable microprobes for neuroscience studies

    Science.gov (United States)

    Cao, H.; Nguyen, C. M.; Chiao, J. C.

    2012-06-01

    In this work implantable micro-probes for central nervous system (CNS) studies were developed on silicon and polyimide substrates. The probes which contained micro-electrode arrays with different surface modifications were designed for implantation in the CNS. The electrode surfaces were modified with nano-scale structures that could greatly increase the active surface area in order to enhance the electrochemical current outputs while maintaining micro-scale dimensions of the electrodes and probes. The electrodes were made of gold or platinum, and designed with different sizes. The silicon probes were modified by silicon nanowires fabricated with the vapor-liquid-solid mechanism at high temperatures. With polyimide substrates, the nanostructure modification was carried out by applying concentrated gold or silver colloid solutions onto the micro-electrodes at room temperature. The surfaces of electrodes before and after modification were observed by scanning electron microscopy. The silicon nanowire-modified surface was characterized by cyclic voltammetry. Experiments were carried out to investigate the improvement in sensing performance. The modified electrodes were tested with H2O2, electrochemical L-glutamate and dopamine. Comparisons between electrodes with and without nanostructure modification were conducted showing that the modifications have enhanced the signal outputs of the electrochemical neurotransmitter sensors.

  15. Factors predicting for postimplantation urinary retention after permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Lee, Nancy; Wuu, C.-S.; Brody, Rachel; Laguna, Joe L.; Katz, Aaron E.; Bagiella, Emilia; Ennis, Ronald D.

    2000-01-01

    Purpose: Urinary retention requiring catheterization is a known complication among prostate cancer patients treated with permanent interstitial radioactive seed implantation. However, the factors associated with this complication are not well known. This study was conducted to determine these factors. Methods and Materials: Ninety-one consecutive prostate cancer patients treated with permanent interstitial implantation at our institution from 1996 to 1999 were evaluated. All patients underwent pre-implant ultrasound and postimplant CT volume studies. Isotopes used were 125 I (54 patients) or 103 Pd (37 patients). Twenty-three patients were treated with a combination of 45 Gy of external beam radiation therapy as well as seed implantation, of which only 3 patients were treated with 125 I. Mean pretreatment prostate ultrasound volume was 35.4 cc (range, 10.0-70.2 cc). The mean planning ultrasound target volume (PUTV) was 39.6 cc (range, 16.1-74.5 cc), whereas the mean posttreatment CT target volume was 55.0 cc (range, 20.2-116 cc). Patient records were reviewed to determine which patients required urinary catheterization for relief of urinary obstruction. The following factors were analyzed as predictors for urinary retention: clinical stage; Gleason score; prostate-specific antigen; external beam radiation therapy; hormone therapy; pre-implant urinary symptoms (asymptomatic/nocturia x 1 vs. more significant urinary symptoms); pretreatment ultrasound prostate volume; PUTV; PUTV within the 125%, 150%, 200%, 250%, 300% isodose lines; postimplant CT volume within the 125%, 150%, 200%, 250%, 300% isodose lines; D90; D80; D50; ratio of post-CT volume to the PUTV; the absolute change in volume between the CT volume and PUTV; number of needles used; activity per seed; and the total activity of the implant. Statistical analyses using logistic regression and χ2 were performed. Results: Eleven of 91 (12%) became obstructed. Significant factors predicting for urinary retention

  16. Relato de caso: implante transparietohepático de cateter de longa permanência para diálise Case report: transhepatic insertion of long-term dialysis catheter

    Directory of Open Access Journals (Sweden)

    Felipe Nasser

    2007-12-01

    Full Text Available O implante transhepático de cateteres de diálise de longa permanência é um procedimento de exceção, utilizado para obter um acesso em pacientes com oclusão de veias centrais de membros superiores e inferiores. O caso descrito relata um paciente jovem, com história de 15 anos de diálise, que foi submetido no passado a um transplante renal sem sucesso. Esse paciente encontrava-se em urgência dialítica e oclusão comprovada de veias centrais de membros superiores e de veias ilíacas. Foi realizado o implante do cateter de longa permanência pelo acesso transparietohepático sob anestesia geral. A ponta do cateter foi posicionada ao nível do átrio direito. A diálise foi realizada satisfatoriamente no mesmo dia.Transhepatic insertion of long-term dialysis catheter is an exception procedure used to obtain access in patients with central vein occlusion of lower and upper limbs. We report on a case of a young patient with history of dialysis for 15 years, who was submitted to an unsuccessful renal transplantation. This patient was in dialytic emergency and had confirmed occlusion of upper limb central veins and iliac veins. Transhepatic insertion of a long-term catheter was performed under general anesthesia. The catheter tip was placed at the level of the right atrium. Dialysis was satisfactorily performed on the same day.

  17. Labyrinthectomy with cochlear implantation.

    Science.gov (United States)

    Zwolan, T A; Shepard, N T; Niparko, J K

    1993-05-01

    Numerous reports indicate that the cochlea remains responsive to electrical stimulation following labyrinthectomy. We report a case of a 47-year-old woman with a severe to profound sensorineural hearing loss from birth, who developed episodic vertigo with symptoms suggestive of delayed onset endolymphatic hydrops. Following 8 months of failed medical and vestibular rehabilitation management, a right-sided labyrinthectomy combined with cochlear implantation was performed without complication. Postoperatively the patient was free of vertigo. Attempts to activate the patient's device between 4 to 12 weeks after surgery were unsuccessful as stimulation of the electrodes resulted in discomfort. However, all 20 electrodes elicited comfortable hearing sensations 16 weeks postsurgery. One year after the successful activation, the patient demonstrated improved sound awareness and speech recognition with the implant when compared with preoperative performance with a hearing aid. This case study suggests that electrical detection thresholds with prosthetic stimulation may be unstable in the recently labyrinthectomized ear but supports and extends prior observations of preserved cochlear responsiveness after labyrinthectomy.

  18. Quantum effects in ion implanted devices

    International Nuclear Information System (INIS)

    Jamieson, D.N.; Chan, V.; Hudson, F.E.; Andresen, S.E.; Yang, C.; Hopf, T.; Hearne, S.M.; Pakes, C.I.; Prawer, S.; Gauja, E.; Yang, C.; Dzurak, A.S.; Yang, C.; Clark, R.G.; Yang, C.

    2005-01-01

    Fabrication of nanoscale devices that exploit the rules of quantum mechanics to process information presents formidable technical challenges because it will be necessary to control quantum states at the level of individual atoms, electrons or photons. We have developed a pathway to the construction of quantum devices using ion implantation and demonstrate, using charge transport analysis, that the devices exhibit single electron effects. We construct devices that employ two P donors in Si by employing the technique of ion beam induced charge (IBIC) in which single 14 keV P ions can be implanted into ultra-pure silicon by monitoring on-substrate detector electrodes. We have used IBIC with a MeV nuclear microprobe to map and measure the charge collection efficiency in the development of the electrode structure and show that 100% charge collection efficiency can be achieved leading to the fabrication of prototype devices that display quantum effects in the transport of single charge quanta between the islands of implanted donors. (author). 9 refs., 4 figs., 1 tab

  19. Aqueous shunt implantation in glaucoma

    Directory of Open Access Journals (Sweden)

    Jing Wang

    2017-01-01

    Full Text Available Aqueous shunts or glaucoma drainage devices are increasingly utilized in the management of refractory glaucoma. The general design of the most commonly-used shunts is based on the principles of the Molteno implant: ie. a permanent sclerostomy (tube, a predetermined bleb area (plate and diversion of aqueous humour to the equatorial region and away from the limbal subconjunctival space. These three factors make aqueous shunts more resistant to scarring as compared to trabeculectomy. The two most commonly used shunts are the Ahmed Glaucoma Valve, which contains a flow-restrictor, and the non-valved Baervedlt Glaucoma Implant. While the valved implants have a lower tendency to hypotony and related complications, the non-valved implants with larger, more-biocompatible end plate design, achieve lower intraocular pressures with less encapsulation. Non-valved implants require additional suturing techniques to prevent early hypotony and a number of these methods will be described. Although serious shunt-related infection is rare, corneal decompensation and diplopia are small but significant risks.

  20. Characterization of Fast-Scan Cyclic Voltammetric Electrodes Using Paraffin as an Effective Sealant with In Vitro and In Vivo Applications.

    Science.gov (United States)

    Ramsson, Eric S; Cholger, Daniel; Dionise, Albert; Poirier, Nicholas; Andrus, Avery; Curtiss, Randi

    2015-01-01

    Fast-scan cyclic voltammetry (FSCV) is a powerful technique for measuring sub-second changes in neurotransmitter levels. A great time-limiting factor in the use of FSCV is the production of high-quality recording electrodes; common recording electrodes consist of cylindrical carbon fiber encased in borosilicate glass. When the borosilicate is heated and pulled, the molten glass ideally forms a tight seal around the carbon fiber cylinder. It is often difficult, however, to guarantee a perfect seal between the glass and carbon. Indeed, much of the time spent creating electrodes is in an effort to find a good seal. Even though epoxy resins can be useful in this regard, they are irreversible (seals are permanent), wasteful (epoxy cannot be reused once hardener is added), hazardous (hardeners are often caustic), and require curing. Herein we characterize paraffin as an electrode sealant for FSCV microelectrodes. Paraffin boasts the advantages of near-immediate curing times, simplicity in use, long shelf-life and stable waterproof seals capable of withstanding extended cycling. Borosilicate electrode tips were left intact or broken and dipped in paraffin embedding wax. Excess wax was removed from the carbon surface with xyelenes or by repeated cycling at an extended waveform (-0.4 to 1.4V, 400 V/s, 60 Hz). Then, the waveform was switched to a standard waveform (-0.4 to 1.3V, 400 V/s, 10 Hz) and cycled until stable. Wax-sealing does not inhibit electrode sensitivity, as electrodes detected linear changes in dopamine before and after wax (then xylenes) exposure. Paraffin seals are intact after 11 days of implantation in the mouse, and still capable of measuring transient changes in in vivo dopamine. From this it is clear that paraffin wax is an effective sealant for FSCV electrodes that provides a convenient substitute to epoxy sealants.

  1. An implantable two axis micromanipulator made with a 3D printer for recording neural activity in free-swimming fish.

    Science.gov (United States)

    Rogers, Loranzie S; Van Wert, Jacey C; Mensinger, Allen F

    2017-08-15

    Chronically implanted electrodes allow monitoring neural activity from free moving animals. While a wide variety of implanted headstages, microdrives and electrodes exist for terrestrial animals, few have been developed for use with aquatic animals. A two axis micromanipulator was fabricated with a Formlabs 3D printer for implanting electrodes into free-swimming oyster toadfish (Opsanus tau). The five piece manipulator consisted of a base, body, electrode holder, manual screw drive and locking nut. The manipulator measured approximately 25×20×30mm (l×w×h) and weighed 5.28g after hand assembly. Microwire electrodes were inserted successfully with the manipulator to record high fidelity signals from the anterior lateral line nerve of the toadfish. The micromanipulator allowed the chronically implanted electrodes to be repositioned numerous times to record from multiple sites and extended successful recording time in the toadfish by several days. Three dimensional printing allowed an inexpensive (<$US 5 material), two axis micromanipulator to be printed relatively rapidly (<2h) to successfully record from multiple sites in the anterior lateral line nerve of free-swimming toadfish. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Treatment of spasmodic dysphonia with a neuromodulating electrical implant.

    Science.gov (United States)

    Pitman, Michael J

    2014-11-01

    To investigate the feasibility of an implantable electrical stimulation device to treat spasmodic dysphonia (SD) by neuromodulation of the muscle spindle gamma loop. Prospective case series. Five subjects underwent daily stimulation of the left thyroarytenoid muscle (TA) below the level of α-motor neuron activation (AMNA) for 5 consecutive days. Professional and patient voice evaluations were performed. Transcartilagenous placement of an implantable stimulation device lead was investigated in anesthetized porcine and cadaveric human models. Three of 5 subjects improved in all categories of evaluation. One subject improved in three of four categories. These four subjects described significant carryover of effect after treatment. The fifth subject evidenced improvement until contracting an upper respiratory infection on day 3. Transcartilagenous electrode placement into the porcine TA with muscle stimulation was successful. The electrode lead was passed from the cadaveric larynx to the mastoid tip in the subplatysma layer with an absence of tension. The symptoms of SD improve after electrical stimulation of the TA at levels below AMNA. This is likely through neuromodulation of the muscle spindle gamma loop. Implantation of an electrode into the TA with a postauricular implanted stimulator is feasible with modifications of an already existing device. With further investigation, such a device has the potential to deliver an alternative treatment for SD. 4. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  3. Neurotrophic treatment of the degenerating auditory nerve; cochlear implants in deafened guinea pigs

    NARCIS (Netherlands)

    Agterberg, M.J.H.

    2009-01-01

    To date, the cochlear implant is the most successful sensorineural prosthesis. The device consists of a small array with a number of electrodes implanted in the cochlea of profoundly hearing impaired people. Some people with an implant are able to use the telephone. Unfortunately, others hardly

  4. [Applied anatomy of scala tympani inlet related to cochlear implantation].

    Science.gov (United States)

    Zou, Tuanming; Guo, Menghe; Zhang, Hongzheng; Shu, Fan; Xie, Nanping

    2012-06-01

    To investigate the related parameters of the temporal bone structure for determining the position of implanting electrode into the scala tympani in cochlear implantation surgery through the facial recess and epitympanum approach. In a surgical simulation experiment, 20 human temporal bones were studied and measured to determine the related parameters of the temporal bone structure. The distance 5.91∓0.29 mm between the short process of the incus and the round window niche, 2.11∓0.18 mm between the stapes and the round window niche, 6.70∓0.19 mm between the facial nerve in the perpendicular paragraph and the round window niche, 2.22∓0.21 mm from the pyramidal eminence to the round window, and 2.16∓0.14 mm between the stapes and the round window. The minimal distance between the implanting electrode and the vestibular window was 2.12∓0.19 mm. The distance between the cochleariform process and the round window niche was 3.79∓0.17 mm. The position of the cochlear electrode array insertion into the second cochlear turn was 2.25∓0.13 mm under the stapes. The location of the cochlear electrode array insertion into the second cochlear turn was 2.28∓0.20 mm inferior to the pyramidal eminence. These parameters provide a reference value to determine the different positions of cochlear electrode array insertion into the scale tympani in different patients.

  5. Concept and Development of an Electronic Framework Intended for Electrode and Surrounding Environment Characterization In Vivo

    Directory of Open Access Journals (Sweden)

    Stefan B. Rieger

    2016-12-01

    Full Text Available There has been substantial progress over the last decade towards miniaturizing implantable microelectrodes for use in Active Implantable Medical Devices (AIMD. Compared to the rapid development and complexity of electrode miniaturization, methods to monitor and assess functional integrity and electrical functionality of these electrodes, particularly during long term stimulation, have not progressed to the same extent. Evaluation methods that form the gold standard, such as stimulus pulse testing, cyclic voltammetry and electrochemical impedance spectroscopy, are either still bound to laboratory infrastructure (impractical for long term in vivo experiments or deliver no comprehensive insight into the material’s behaviour. As there is a lack of cost effective and practical predictive measures to understand long term electrode behaviour in vivo, material investigations need to be performed after explantation of the electrodes. We propose the analysis of the electrode and its environment in situ, to better understand and correlate the effects leading to electrode failure. The derived knowledge shall eventually lead to improved electrode designs, increased electrode functionality and safety in clinical applications. In this paper, the concept, design and prototyping of a sensor framework used to analyse the electrode’s behaviour and to monitor diverse electrode failure mechanisms, even during stimulation pulses, is presented. We focused on the electronic circuitry and data acquisition techniques required for a conceptual multi-sensor system. Functionality of single modules and a prototype framework have been demonstrated, but further work is needed to convert the prototype system into an implantable device. In vitro studies will be conducted first to verify sensor performance and reliability.

  6. Dosimetric results in implant and post-implant and low rate in brachytherapy prostate cancer with loose seeds and attached; Resultados dosimetricos en el implante y post-impante en braquiterapia de baja tasa en cancer de prostata con semillas sueltas y unidas

    Energy Technology Data Exchange (ETDEWEB)

    Juan-Senabre, X. J.; Albert Antequera, M.; Lopez-Tarjuelo, J.; Santos Serra, A.; Perez-Mestre, M.; Sanchez Iglesias, A. L.; Conde Moreno, A. J.; Gonzalez Vidal, V.; Beltran Persiva, J.; Muelas Soria, R.; Ferrer Albiach, C.

    2015-07-01

    The objective is determine differences dosimetry statistics on the dosimetry of the implant and post-implant in brachytherapy of low rate with implants permanent in prostate using seed of 125-I loose and attached Both in lives and in the post-prostatic plans dosimetric coverage is good and restrictions in urethra and rectum for both groups of patients are met. Not migrating with joined is evident, as well as better dosimetric homogeneity. (Author)

  7. Dosimetric effects of edema in permanent prostate seed implants: a rigorous solution

    International Nuclear Information System (INIS)

    Chen Zhe; Yue Ning; Wang Xiaohong; Roberts, Kenneth B.; Peschel, Richard; Nath, Ravinder

    2000-01-01

    Purpose: To derive a rigorous analytic solution to the dosimetric effects of prostate edema so that its impact on the conventional pre-implant and post-implant dosimetry can be studied for any given radioactive isotope and edema characteristics. Methods and Materials: The edema characteristics observed by Waterman et al (Int. J. Rad. Onc. Biol. Phys, 41:1069-1077; 1998) was used to model the time evolution of the prostate and the seed locations. The total dose to any part of prostate tissue from a seed implant was calculated analytically by parameterizing the dose fall-off from a radioactive seed as a single inverse power function of distance, with proper account of the edema-induced time evolution. The dosimetric impact of prostate edema was determined by comparing the dose calculated with full consideration of prostate edema to that calculated with the conventional dosimetry approach where the seed locations and the target volume are assumed to be stationary. Results: A rigorous analytic solution on the relative dosimetric effects of prostate edema was obtained. This solution proved explicitly that the relative dosimetric effects of edema, as found in the previous numerical studies by Yue et. al. (Int. J. Radiat. Oncol. Biol. Phys. 43, 447-454, 1999), are independent of the size and the shape of the implant target volume and are independent of the number and the locations of the seeds implanted. It also showed that the magnitude of relative dosimetric effects is independent of the location of dose evaluation point within the edematous target volume. It implies that the relative dosimetric effects of prostate edema are universal with respect to a given isotope and edema characteristic. A set of master tables for the relative dosimetric effects of edema were obtained for a wide range of edema characteristics for both 125 I and 103 Pd prostate seed implants. Conclusions: A rigorous analytic solution of the relative dosimetric effects of prostate edema has been

  8. Analysis of a five year experience of permanent pacemaker implantation at a Nigerian Teaching Hospital: need for a national database

    Science.gov (United States)

    Falase, Bode; Sanusi, Michael; Johnson, Adeyemi; Akinrinlola, Fola; Ajayi, Reina; Oke, David

    2013-01-01

    Introduction Permanent pacemaker implantation is available in Nigeria. There is however no national registry or framework for pacemaker data collection. A pacemaker database has been developed in our institution and the results are analyzed in this study. Methods The study period was between January 2008 and December 2012. Patient data was extracted from a prospectively maintained database which was designed to include the fields of the European pacemaker patient identification code. Results Of the 51 pacemaker implants done, there were 29 males (56.9%) and 22 females (43.1%). Mean age was 68.2±12.7 years. Clinical indications were syncopal attacks in 25 patients (49%), dizzy spells in 15 patients (29.4%), bradycardia with no symptoms in 10 patients (17.7%) and dyspnoea in 2 patients (3.9%). The ECG diagnosis was complete heart block in 27 patients (53%), second degree heart block in 19 patients (37.2%) and sick sinus syndrome with bradycardia in 5 patients (9.8%). Pacemaker modes used were ventricular pacing in 29 patients (56.9%) and dual chamber pacing in 22 patients (43.1%). Files have been closed in 20 patients (39.2%) and 31 patients (60.8%) are still being followed up with median follow up of 26 months, median of 5 visits and 282 pacemaker checks done. Complications seen during follow up were 3 lead displacements (5.9%), 3 pacemaker infections (5.9%), 2 pacemaker pocket erosions (3.9%), and 1 pacemaker related death (2%). There were 5 non-pacemaker related deaths (9.8%). Conclusion Pacemaker data has been maintained for 5 years. We urge other implanting institutions in Nigeria to maintain similar databases and work towards establishment of a national pacemaker registry. PMID:24498465

  9. Selenium implantation in epitaxial gallium arsenide layers

    International Nuclear Information System (INIS)

    Inada, T.; Tokunaga, K.; Taka, S.; Yuge, Y.; Kohzu, H.

    1981-01-01

    Selenium implantation at room temperature in S-doped epitaxial GaAs layers as a means of the formation of n + layers has been investigated. Doping profiles for Se-implanted layers have been examined by a C-V technique and/or a differential Hall effect method. It has been shown that n + layers with a maximum carrier concentration of approx. equal to1.5 x 10 18 cm -3 can be formed by implantation followed by a 15 min annealing at 950 0 C. Contact resistance of ohmic electrodes is reduced by use of the Se-implanted n + layers, resulting in the improvement on GaAs FET performance. Measured minimum noise figure of the Se-implanted GaAs FETs is 0.74 dB at 4 GHz. (orig.)

  10. An analysis of brachytherapy with computed tomography-guided permanent implantation of Iodine-125 seeds for recurrent nonkeratin nasopharyngeal carcinoma

    Directory of Open Access Journals (Sweden)

    Shen X

    2015-05-01

    Full Text Available Xinying Shen,1,2 Yong Li,2 Yanfang Zhang,2 Jian Kong,2 Yanhao Li1 1Department of Interventional Radiology, Nanfang Hospital, Southern Medical University, Guangzhou, 2Department of Interventional Radiology, Shenzhen People’s Hospital, The Second Clinical Medical College of Jinan University, Shenzhen, People’s Republic of China Background: 125I seed implantation is a new method in treatment of nasopharyngeal carcinoma (NPC, and it is worthwhile to evaluate its feasibility. In this study, we performed brachytherapy with computed tomography (CT-guided permanent implantation of 125I seeds in the treatment of patients with the recurrence of NPC.Methods: A total 30 patients (20 male and ten female at the median age of 55 (range 25–80 years were diagnosed with recurrent nonkeratin NPC, with a total 38 lesions and a short disease-free interval (median ~11 months after primary radiotherapy alone or combined with chemotherapy. Patients received CT scan, starting from 2 months after the treatment. Follow-up was conducted for ~2–38 months to observe the local control rate and overall survival rate. We also analyzed the possible correlation between survival periods and the status of recurrent tumors.Results: The local control rates at 6, 12, 24, 30, and 36 months after the procedure of 125I seed implantation were 86.8%, 73.7%, 26.3%, 15.8%, and 5.3%, respectively. The overall 1-, 2-, and 3-year survival rates were 80.0% (24/30, 30.0% (9/30, and 6.7% (2/30, respectively, with a median survival period of 18 months (17.6±8.6 months. Interestingly, the survival periods of the patients who had primary radiotherapy with or without chemotherapy were 15.8±7.9 and 24.3±7.9 months, respectively. Kaplan–Meier survival analysis demonstrated that χ2 (log rank was 7.555, with very significant difference (P<0.01. The survival periods of patients in tumor stages I, II, III, and IV were 25.4±8.7, 19.8±9.4, 16.1±4.5, and 12.8±7.8 months, respectively, with

  11. The study of the radiation protection problem in the radionuclide interstitial implantation therapy

    International Nuclear Information System (INIS)

    Zhang Jimian

    2006-01-01

    Objective: To analyze and study the radiation protection problem in the radionuclide interstitial permanent implantation therapy. Methods: Based on test data from radioactive measurement department, calculating results and national standards, the radiation dose of the exposed radioactive particles, the operator who has participated in the radionuclide interstitial permanent implantation therapy operation and the relatives who have accompanied the patient during the whole course, the reference time of being discharged from hospital for the patients who have been cured by different activity of radioactive particles are studied. Results: The maximal radiation dose of operating doctor who has participated in a single radionuclide interstitial permanent implantation therapy operation and the relatives who has accompanied the patient during the whole course are 0.315 mSv/a and 0.70 mSv. Based on actual contact frequencies, their radiation dose is proved to be smaller than the restricted dose prescribed by national standards. The reference time of leaving hospital for the patients who have been cured by different activity of radioactive particles is 0 to 44 days. Conclusion: The radiation dose of radiation workers and surrounding publics in the radionuclide interstitial permanent implantation therapy operation can be acceptable under certain shields. But the risk of potential exposure should be guarded. The authors should Lay down operation indications and avoid performing operation blindly. If one must be operated, the authors should plan the quantity and the part of the painting radioactive particles accurately in order to avoid some passible complications. (authors)

  12. A study on setting of the fatigue limit of temporary dental implants.

    Science.gov (United States)

    Kim, M H; Cho, E J; Lee, J W; Kim, E K; Yoo, S H; Park, C W

    2017-07-01

    A temporary dental implant is a medical device which is temporarily used to support a prosthesis such as an artificial tooth used for restoring patient's masticatory function during implant treatment. It is implanted in the oral cavity to substitute for the role of tooth. Due to the aging and westernization of current Korean society, the number of tooth extraction and implantation procedures is increasing, leading to an increase in the use and development of temporary dental implants. Because an implant performs a masticatory function in place of a tooth, a dynamic load is repeatedly put on the implant. Thus, the fatigue of implants is reported to be the most common causes of the fracture thereof. According to the investigation and analysis of the current domestic and international standards, the standard for fatigue of implant fixtures is not separately specified. Although a test method for measuring the fatigue is suggested in an ISO standard, it is a standard for permanent dental implants. Most of the test standards for Korean manufacturers and importers apply 250 N or more based on the guidance for the safety and performance evaluation of dental implants. Therefore, this study is intended to figure out the fatigue standard which can be applied to temporary dental implants when measuring the fatigue according to the test method suggested in the permanent dental implant standard. The results determined that suitable fatigue standards of temporary dental implants should be provided by each manufacturer rather than applying 250 N. This study will be useful for the establishment of the fatigue standards and fatigue test methods of the manufacturers and importers of temporary dental implants.

  13. Multicenter surgical experience evaluation on the Mid-Scala electrode and insertion tools.

    Science.gov (United States)

    Gazibegovic, Dzemal; Bero, Eva M

    2017-02-01

    The HiFocus Mid-Scala electrode is intended to improve hearing for individuals with severe-to-profound hearing loss by providing extended electrical coverage of the cochlea while minimizing trauma related to insertion. The electrode is appropriate for use with a wide range of surgical techniques, including either a cochleostomy or round window insertion, and the use of either a free-hand or tool-assisted approach. The objective of this survey was to evaluate how the HiFocus Mid-Scala electrode and insertion tools was used across a population of cochlear implant recipients of differing ages, audiologic profiles, and anatomical characteristics. The intent was to understand the type and frequency of surgical techniques applicable with the electrode, and to provide guidelines for clinical practice. Two questionnaires were completed by surgeons at implant centres located in the United States, Europe, and Asia. Before any surgeries were conducted, surgeons completed a questionnaire that assessed their overall cochlear implant surgical practice and preferences. Following each HiFocus Mid-Scala electrode insertion, surgeons completed a questionnaire that summarized their experience during that surgical procedure. Questionnaires were completed by 32 surgeons from 16 centres for a total of 143 surgeries (112 adults, 31 children). Most surgeons (62 %) preferred to insert the electrode via the round window or an extended round window compared with a cochleostomy (16 %), whereas the remaining 22 % indicated that they made an insertion choice based on presenting anatomy. Sixty-nine percent preferred a free-hand approach over using insertion tools. In 32 procedures, surgeons elected to deviate from an intended round window insertion to either an extended round window or cochleostomy approach.

  14. Influence of source batch S{sub K} dispersion on dosimetry for prostate cancer treatment with permanent implants

    Energy Technology Data Exchange (ETDEWEB)

    Nuñez-Cumplido, E., E-mail: ejnc-mccg@hotmail.com; Hernandez-Armas, J. [Medical Physics Department, University Hospital of the Canary Island, La Cuesta – Ofra, 38003 La Laguna (Spain); Perez-Calatayud, J. [Radiotherapy Department, La Fe University Hospital, Bulevar Sur, 46026 Valencia (Spain); Casares-Magaz, O. [Medical Physics Department, University Hospital of the Canary Island, La Cuesta – Ofra, 38003 La Laguna, Spain and Medical Physics Department, Aarhus University Hospital, Nørrebrogade 44, 8000 Aarhus (Denmark)

    2015-08-15

    Purpose: In clinical practice, specific air kerma strength (S{sub K}) value is used in treatment planning system (TPS) permanent brachytherapy implant calculations with {sup 125}I and {sup 103}Pd sources; in fact, commercial TPS provide only one S{sub K} input value for all implanted sources and the certified shipment average is typically used. However, the value for S{sub K} is dispersed: this dispersion is not only due to the manufacturing process and variation between different source batches but also due to the classification of sources into different classes according to their S{sub K} values. The purpose of this work is to examine the impact of S{sub K} dispersion on typical implant parameters that are used to evaluate the dose volume histogram (DVH) for both planning target volume (PTV) and organs at risk (OARs). Methods: The authors have developed a new algorithm to compute dose distributions with different S{sub K} values for each source. Three different prostate volumes (20, 30, and 40 cm{sup 3}) were considered and two typical commercial sources of different radionuclides were used. Using a conventional TPS, clinically accepted calculations were made for {sup 125}I sources; for the palladium, typical implants were simulated. To assess the many different possible S{sub K} values for each source belonging to a class, the authors assigned an S{sub K} value to each source in a randomized process 1000 times for each source and volume. All the dose distributions generated for each set of simulations were assessed through the DVH distributions comparing with dose distributions obtained using a uniform S{sub K} value for all the implanted sources. The authors analyzed several dose coverage (V{sub 100} and D{sub 90}) and overdosage parameters for prostate and PTV and also the limiting and overdosage parameters for OARs, urethra and rectum. Results: The parameters analyzed followed a Gaussian distribution for the entire set of computed dosimetries. PTV and

  15. Evolution of impedance field telemetry after one day of activation in cochlear implant recipients.

    Directory of Open Access Journals (Sweden)

    Hao-Chun Hu

    Full Text Available Changes in impedance between 24 hours and one month after cochlear implantation have never been explored due to the inability to switch on within one day. This study examined the effect of early activation (within 24 hours on the evolution of electrode impedance with the aim of providing information on the tissue-to-electrode interface when electrical stimulation was commenced one day post implantation.We performed a retrospective review at a single institution. Patients who received a Nucleus 24RECA implant system (Cochlear, Sydney, Australia and underwent initial switch-on within 24 hours postoperatively were included. Impedance measurements were obtained intraoperatively and postoperatively at 1 day, 1 week, 4 weeks, and 8 weeks.A significant drop in impedance was noted 1 day after an initial activation within 24 hours followed by a significant rise in impedance in all channels until 1 week, after which the impedance behaved differently in different segments. Basal and mid-portion electrodes revealed a slight increase while apical electrodes showed a slight decrease in impedance from 1 week to 8 weeks postoperatively. Impedance was relatively stable 4 weeks after surgery.This is the first study to report the evolution of impedance in all channels between initial mapping 1 day and 1 month after cochlear implantation. The underlying mechanism for the differences in behavior between different segments of the electrode may be associated with the combined effect of dynamics among the interplay of cell cover formation, electrical stimulation, and fibrotic reaction.

  16. Implantable biochemical fuel cell

    Energy Technology Data Exchange (ETDEWEB)

    Richter, G; Rao, J R

    1978-01-05

    Implantable biochemical fuel cells for the operation of heart pacemakers or artificial hearts convert oxidisable body substances such as glucose on the anode side and reduce the oxygen contained in body fluids at the cathode. The anode and cathode are separated by membranes which are impermeable to albumen and blood corpuscles in body fluids. A chemical shortcircuit cannot occur in practice if, according to the invention, one or more selective oxygen electrodes with carbon as catalyst are arranged so that the mixture which diffuses into the cell from body fluids during operation reaches the fuel cell electrode through the porous oxygen electrode. The membranes used must be permeable to water. Cellulose, polymerised polyvinyl alcohol or an ion exchanger with a buffering capacity between pH5 and 8 act as permeable materials.

  17. Update on the Essure System for Permanent Birth Control.

    Science.gov (United States)

    Fantasia, Heidi Collins

    In 2002, the U.S. Food and Drug Administration approved the Essure system for permanent birth control. Implantation with this device offers a minimally invasive option for permanent female contraception that is placed during a brief office visit. Unlike laparoscopic tubal sterilization, the Essure procedure requires no hospitalization or general anesthesia, resulting in minimal recovery time. After a decade of stability in the report of adverse effects, the U.S. Food and Drug Administration noted a sharp increase in patient-reported adverse events, including chronic pelvic pain, irregular bleeding, allergic reactions, and autoimmune-like reactions. In response to this increase in complaints, the U.S. Food and Drug Administration issued updated guidelines for patient education and counseling. This article discusses those updates, as well as implications for nurses who provide health care to women seeking permanent contraception. © 2017 AWHONN, the Association of Women’s Health, Obstetric and Neonatal Nurses.

  18. Hearing Preservation in Cochlear Implant Surgery

    Directory of Open Access Journals (Sweden)

    Priscila Carvalho Miranda

    2014-01-01

    Full Text Available In the past, it was thought that hearing loss patients with residual low-frequency hearing would not be good candidates for cochlear implantation since insertion was expected to induce inner ear trauma. Recent advances in electrode design and surgical techniques have made the preservation of residual low-frequency hearing achievable and desirable. The importance of preserving residual low-frequency hearing cannot be underestimated in light of the added benefit of hearing in noisy atmospheres and in music quality. The concept of electrical and acoustic stimulation involves electrically stimulating the nonfunctional, high-frequency region of the cochlea with a cochlear implant and applying a hearing aid in the low-frequency range. The principle of preserving low-frequency hearing by a “soft surgery” cochlear implantation could also be useful to the population of children who might profit from regenerative hair cell therapy in the future. Main aspects of low-frequency hearing preservation surgery are discussed in this review: its brief history, electrode design, principles and advantages of electric-acoustic stimulation, surgical technique, and further implications of this new treatment possibility for hearing impaired patients.

  19. Scalar position in cochlear implant surgery and outcome in residual hearing and the vestibular system.

    Science.gov (United States)

    Nordfalk, Karl Fredrik; Rasmussen, Kjell; Hopp, Einar; Greisiger, Ralf; Jablonski, Greg Eigner

    2014-02-01

    To evaluate the effect of the intracochlear electrode position on the residual hearing and VNG- and cVEMP responses. Prospective pilot study. Thirteen adult patients who underwent unilateral cochlear implant surgery were examined with high-resolution rotational tomography after cochlear implantation. All subjects were also tested with VNG, and 12 of the subjects were tested with cVEMP and audiometry before and after surgery. We found that although the electrode was originally planned to be positioned inside the scala tympani, only 8 of 13 had full insertion into the scala tympani. Loss of cVEMP response occurred to the same extent in the group with full scala tympani positioning and the group with scala vestibuli involvement. There was a non-significant difference in the loss of caloric response and residual hearing between the two groups. Interscalar dislocation of the electrode inside the cochlea was observed in two patients. A higher loss of residual hearing could be seen in the group with electrode dislocation between the scalae. Our findings indicate that intracochlear electrode dislocation is a possible cause to loss of residual hearing during cochlear implantation but cannot be the sole cause of postoperative vestibular loss.

  20. Evidence of across-channel processing for spectral-ripple discrimination in cochlear implant listeners.

    Science.gov (United States)

    Won, Jong Ho; Jones, Gary L; Drennan, Ward R; Jameyson, Elyse M; Rubinstein, Jay T

    2011-10-01

    Spectral-ripple discrimination has been used widely for psychoacoustical studies in normal-hearing, hearing-impaired, and cochlear implant listeners. The present study investigated the perceptual mechanism for spectral-ripple discrimination in cochlear implant listeners. The main goal of this study was to determine whether cochlear implant listeners use a local intensity cue or global spectral shape for spectral-ripple discrimination. The effect of electrode separation on spectral-ripple discrimination was also evaluated. Results showed that it is highly unlikely that cochlear implant listeners depend on a local intensity cue for spectral-ripple discrimination. A phenomenological model of spectral-ripple discrimination, as an "ideal observer," showed that a perceptual mechanism based on discrimination of a single intensity difference cannot account for performance of cochlear implant listeners. Spectral modulation depth and electrode separation were found to significantly affect spectral-ripple discrimination. The evidence supports the hypothesis that spectral-ripple discrimination involves integrating information from multiple channels. © 2011 Acoustical Society of America

  1. Electrode-tissues interface: modeling and experimental validation

    International Nuclear Information System (INIS)

    Sawan, M; Laaziri, Y; Mounaim, F; Elzayat, E; Corcos, J; Elhilali, M M

    2007-01-01

    The electrode-tissues interface (ETI) is one of the key issues in implantable devices such as stimulators and sensors. Once the stimulator is implanted, safety and reliability become more and more critical. In this case, modeling and monitoring of the ETI are required. We propose an empirical model for the ETI and a dedicated integrated circuit to measure its corresponding complex impedance. These measurements in the frequency range of 1 Hz to 100 kHz were achieved in acute dog experiments. The model demonstrates a closer fitting with experimental measurements. In addition, a custom monitoring device based on a stimuli current generator has been completed to evaluate the phase shift and voltage across the electrodes and to transmit wirelessly the values to an external controller. This integrated circuit has been fabricated in a CMOS 0.18 μm process, which consumes 4 mW only during measurements and occupies an area of 1 mm 2 . (review article)

  2. Electrochemical properties of polypyrrole/polyfuran polymer composite electrode

    International Nuclear Information System (INIS)

    Cha, Seong Keuck

    1998-01-01

    Poly pyrrole polymer(ppy) has an excellent electrical conductivity and can be easily polymerized on anode to give various morphology according to doped anion on electroactive sites. To improve the properties of brittleness, ageing and hydrophobicity, poly furan polymer(pfu) having a high initiation potential was anodically implanted in this porous ppy film matrix to get the Pt/ppy/pfu(x)type of polymer campsite electrode. Cyclic voltammetry and electrochemical impedance methods were used to these electrode, where PF 6 - , BF 4 - , and ClO 4 - ions were employed as dopants. The composition of the pfu(x) at the electrode was changed from 0 to 1.10, but the range was useful only at 0.1 to 0.2 as the redox electrode. The polymer composite electrode doped with PF 6 - was better in charge transfer resistance by a factor of 40 times and in double layer capacitance by a factor of 20 times than others. The charge transfer in the polymer film of the electrode was influenced on frequency change and equivalent circuit of this electrode had Warburg impedance including mass transfer

  3. Comparisons between detection threshold and loudness perception for individual cochlear implant channels

    Science.gov (United States)

    Bierer, Julie Arenberg; Nye, Amberly D

    2014-01-01

    Objective The objective of the present study, performed in cochlear implant listeners, was to examine how the level of current required to detect single-channel electrical pulse trains relates to loudness perception on the same channel. The working hypothesis was that channels with relatively high thresholds, when measured with a focused current pattern, interface poorly to the auditory nerve. For such channels a smaller dynamic range between perceptual threshold and the most comfortable loudness would result, in part, from a greater sensitivity to changes in electrical field spread compared to low-threshold channels. The narrower range of comfortable listening levels may have important implications for speech perception. Design Data were collected from eight, adult cochlear implant listeners implanted with the HiRes90k cochlear implant (Advanced Bionics Corp.). The partial tripolar (pTP) electrode configuration, consisting of one intracochlear active electrode, two flanking electrodes carrying a fraction (σ) of the return current, and an extracochlear ground, was used for stimulation. Single-channel detection thresholds and most comfortable listening levels were acquired using the most focused pTP configuration possible (σ ≥ 0.8) to identify three channels for further testing – those with the highest, median, and lowest thresholds – for each subject. Threshold, equal-loudness contours (at 50% of the monopolar dynamic range), and loudness growth functions were measured for each of these three test channels using various partial tripolar fractions. Results For all test channels, thresholds increased as the electrode configuration became more focused. The rate of increase with the focusing parameter σ was greatest for the high-threshold channel compared to the median- and low-threshold channels. The 50% equal-loudness contours exhibited similar rates of increase in level across test channels and subjects. Additionally, test channels with the highest

  4. Insertion torque recordings for the diagnosis of contact between orthodontic mini-implants and dental roots: a systematic review

    NARCIS (Netherlands)

    Meursinge Reynders, Reint; Ladu, Luisa; Ronchi, Laura; Di Girolamo, Nicola; de Lange, Jan; Roberts, Nia; Plüddemann, Annette

    2016-01-01

    Most orthodontic mini-implants (OMIs) are inserted between dental roots. The prevalence of contacting these structures is high. Such contacts can cause permanent root damage and implant instability. Increased torque levels during implant insertion (the index test) could be a more accurate and

  5. Selection of permanent pacing position of cardiac ventricle in patients with complete right bundle branch block

    International Nuclear Information System (INIS)

    Yang Minquan; Zhou Jun; Zhu Yan; Wang Jin; Rong Xin; Zhang Xiaoyi

    2005-01-01

    Objective: To find out the optimal pacing localization by comparing different pacing positions of the right ventricle in brady-cardiacarrhythmia patients with complete right bundle branch block. Methods: DDD type of double lumen permanent pacemaker was implanted in each of the 8 cases of sick sinus syndrome (SSS) and/or III degree atrioventricular block (III degree AVB) with complete right bundle branch block in normal heart function or class I. For each patient, four pacing positions in right ventricle were compared and the QRS pacing durations were recorded. The position with the shortest the QRS duration was chosen as the permanent pacing position. Heart function, chest X-rays and left ventricle ejection fraction (LVEF) were followed up after the operation. Results: In all the 8 cases, the posterior septum of the right ventricle were chosen as the permanent pacing position, with the shorter pacing QRS duration than that of pre-operation (P<0.05) and other pacing positions of the right ventricle. All parameters of this permanent pacing position were within the normal range. During the follow-up of 6-36 months, no abnormity was found in cardiac functions. Conclusion: In brady-cardiacarrhythmia patients with complete right bundle branch block, the implantation of permanent pacemaker should be at the junction region of inlet and outlet tracts, of the posterior septum of the right ventricle with ideal physiological function. (authors)

  6. The new mid-scala electrode array: a radiologic and histologic study in human temporal bones.

    Science.gov (United States)

    Hassepass, Frederike; Bulla, Stefan; Maier, Wolfgang; Laszig, Roland; Arndt, Susan; Beck, Rainer; Traser, Lousia; Aschendorff, Antje

    2014-09-01

    To analyze the quality of insertion of the newly developed midscala (MS) electrode, which targets a midscalar electrode position to reduce the risk of trauma to the lateral wall and the modiolus. Modern cochlear implant surgery aims for a safe intracochlear placement of electrode arrays with an ongoing debate regarding cochleostomy or round window (RW) insertion and the use of lateral wall or perimodiolar electrode placement. Intracochlear trauma after insertion of different electrodes depends on insertion mode and electrode design and may result in trauma to the delicate structures of the cochlear. We performed a temporal bone (TB) trial with insertion of the MS electrode in n = 20 TB's after a mastoidectomy and posterior tympanotomy. Insertion was performed either via the RW or a cochleostomy. Electrode positioning, length of insertion, and angle of insertion were analyzed with rotational tomography (RT). TBs were histologically analyzed. Results of RT and histology were compared. Scala tympani (ST) insertion could be accomplished reliably by both RW and via a cochleostomy approach. In 20 TBs, 1 scala vestibuli insertion, 1 incomplete (ST), and 1 elevation of basilar membrane were depicted. No trauma was found in 94.7% of all ST insertions. RT allowed determination of the intracochlear electrode position, which was specified by histologic sectioning. The new MS electrode seems to fulfill reliable atraumatic intracochlear placement via RW and cochleostomy approaches. RT is available for evaluation of intracochlear electrode position, serving as a potential quality control instrument in human implantation.

  7. [Cochlear implant in patients with congenital malformation of the inner ear].

    Science.gov (United States)

    Wan, Liang-cai; Guo, Meng-he; Qian, Yu-hong; Liu, Shuang-xiu; Zhang, Hong-zheng; Chen, Shuai-jun; Chen, Hao; Gong, Jian

    2009-10-01

    To summarize the clinical experience with multi-channel cochlear implantation in patients with inner ear malformations and evaluate and the outcomes of speech rehabilitation. A retrospective study was conducted in 295 patients receiving cochlear implantation from 1998 to 2007, including 25 patients with large vestibular aqueduct syndrome (LVAS), 9 with Modini malformation, and 5 with common cavity deformity. All the patients received the Nucleus24 cochlear implants. In LVAS cases, 4 had Nucleus 24R (ST) implants, 8 had Contuor implants, 10 had Contuor Advance, and the remaining cases used Nucleus24(M) straight-electrode implants. Severe gusher appeared in 3 cases of LVAS, and perilymph fluctuation were seen in other 15 cases. Four patients with Mondini malformation and 2 with common cavity malformation also experienced severe gusher, but the electrodes were inserted smoothly in all the patients without postoperative facial paralysis or cerebrospinal fluid leakage. The hearing threshold in these patients was similar to that in patients with normal cochlear structure. After speech rehabilitation for over 6 months, the abilities of speech discrimination and spoken language improved in all the cases in comparison with the preoperative lingual functions. Multi-channel cochlear implantation can be performed in patients with inner ear malformation, but should not be attempted in patients with poor cochlear and cochlear nerve development. A comprehensive pre-operative radiographic and audiological evaluation is essential.

  8. Evidence of across-channel processing for spectral-ripple discrimination in cochlear implant listeners a

    Science.gov (United States)

    Ho Won, Jong; Jones, Gary L.; Drennan, Ward R.; Jameyson, Elyse M.; Rubinstein, Jay T.

    2011-01-01

    Spectral-ripple discrimination has been used widely for psychoacoustical studies in normal-hearing, hearing-impaired, and cochlear implant listeners. The present study investigated the perceptual mechanism for spectral-ripple discrimination in cochlear implant listeners. The main goal of this study was to determine whether cochlear implant listeners use a local intensity cue or global spectral shape for spectral-ripple discrimination. The effect of electrode separation on spectral-ripple discrimination was also evaluated. Results showed that it is highly unlikely that cochlear implant listeners depend on a local intensity cue for spectral-ripple discrimination. A phenomenological model of spectral-ripple discrimination, as an “ideal observer,” showed that a perceptual mechanism based on discrimination of a single intensity difference cannot account for performance of cochlear implant listeners. Spectral modulation depth and electrode separation were found to significantly affect spectral-ripple discrimination. The evidence supports the hypothesis that spectral-ripple discrimination involves integrating information from multiple channels. PMID:21973363

  9. "COCHLEAR IMPLANTATION IN PATIENTS WITH INNER EAR MALFORMATIONS"

    Directory of Open Access Journals (Sweden)

    P. Borghei S. Abdi

    2004-08-01

    Full Text Available Performing cochlear implantation in patients with inner ear malformation has always been a matter of dispute. This study was designed to analyze the operative findings,complications, and postoperative performance of patients with inner ear anomalies who underwent cochlear implantation. Six patients with inner ear malformations underwent implantation in our academic tertiary referral center from 1997 to 2002. The average follow-up period was 27 months. Malformations included one incomplete partition, one common cavity, one narrow internal acoustic canal (IAC in a patient with Riley-Day syndrome and 3 cases of large vestibular aqueduct. All received multi-channel implants either Nucleus 22 or Clarion device. Facial nerve was anomalous in 2 cases. CSF gusher occurred in 4 patients, which was controlled with packing the cochleostomy site. In all cases, the full length of electrode array was inserted, except one with Mondini's dysplasia where insertion failed in the first operation and was referred to another center for a successful surgery on the opposite ear. No other surgical complications were encountered. In 4 cases, all the 22 electrodes could be activated. All patients showed improved hearing performance after implantation. Four showed open-set speech recognition. The one with narrow IAC showed improved awareness to environmental sounds. In the other case (common cavity, the perception tests could not be performed because of very young age. Cochlear implantation in patients with inner ear malformations is a successful way of rehabilitation, although complications should be expected and auditory responses may be highly variable and relatively moderate.

  10. Fully Implanted Brain-Computer Interface in a Locked-In Patient with ALS.

    Science.gov (United States)

    Vansteensel, Mariska J; Pels, Elmar G M; Bleichner, Martin G; Branco, Mariana P; Denison, Timothy; Freudenburg, Zachary V; Gosselaar, Peter; Leinders, Sacha; Ottens, Thomas H; Van Den Boom, Max A; Van Rijen, Peter C; Aarnoutse, Erik J; Ramsey, Nick F

    2016-11-24

    Options for people with severe paralysis who have lost the ability to communicate orally are limited. We describe a method for communication in a patient with late-stage amyotrophic lateral sclerosis (ALS), involving a fully implanted brain-computer interface that consists of subdural electrodes placed over the motor cortex and a transmitter placed subcutaneously in the left side of the thorax. By attempting to move the hand on the side opposite the implanted electrodes, the patient accurately and independently controlled a computer typing program 28 weeks after electrode placement, at the equivalent of two letters per minute. The brain-computer interface offered autonomous communication that supplemented and at times supplanted the patient's eye-tracking device. (Funded by the Government of the Netherlands and the European Union; ClinicalTrials.gov number, NCT02224469 .).

  11. A Communications Link for an Implantable Electrode Array.

    Science.gov (United States)

    1984-12-01

    be gene -rated from the 256 electrodes in a 16 x 16 array which is narrow enough in bandwidth to be transmitted over a FM radio frequency carrier. The...MARCH 1973 DESIGNED FOR HIGH-SPE ED, MEDIUM-POWER SWITCHINGU AND GENERAL PURPOSE AMPLIFIER APPLICATIONS a hFE ... Guaranteed from 100 1pA to 500 mA

  12. Indication of brachytherapy of prostate with permanent implants

    International Nuclear Information System (INIS)

    Chauveinc, L.; Solignac, S.; Rosenwald, J.C.; Firmin, F.; Cosset, J.M.; Flam, T.; Thiounn, N.

    2002-01-01

    In the last decade, brachytherapy emerged as a particularly appealing new way of treating localized prostate cancer. Recently published 10-12 years biochemical control results appear to be superimposable to the best percentages achieved by surgery or conformal radiotherapy, with a small percentage of complications. This applied to severely patients. Only patients with T1/T2, PSA 60 g, hip mobility limitations, a urinary obstructive syndrome and previous trans-urethral resection lead to difficulties in technical implantation and therefore must be taken into account when discussing brachytherapy. In conclusion, for adequately selected patients, brachytherapy offers a particularly applied alternative to surgery and external radiotherapy, with satisfactory long term biochemical control rates and limited complications. (author)

  13. [Cochlear implant in children: rational, indications and cost/efficacy].

    Science.gov (United States)

    Martini, A; Bovo, R; Trevisi, P; Forli, F; Berrettini, S

    2013-06-01

    A cochlear implant (CI) is a partially implanted electronic device that can help to provide a sense of sound and support speech to severely to profoundly hearing impaired patients. It is constituted by an external portion, that usually sits behind the ear and an internal portion surgically placed under the skin. The external components include a microphone connected to a speech processor that selects and arranges sounds pucked up by the microphone. This is connected to a transmitter coil, worn on the side of the head, which transmits data to an internal receiver coil placed under the skin. The received data are delivered to an array of electrodes that are surgically implanted within the cochlea. The primary neural targets of the electrodes are the spiral ganglion cells which innervate fibers of the auditory nerve. When the electrodes are activated by the signal, they send a current along the auditory nerve and auditory pathways to the auditory cortex. Children and adults who are profoundly or severely hearing impaired can be fitted with cochlear implants. According to the Food and Drug Administration, approximately 188,000 people worldwide have received implants. In Italy it is extimated that there are about 6-7000 implanted patients, with an average of 700 CI surgeries per year. Cochlear implantation, followed by intensive postimplantation speech therapy, can help young children to acquire speech, language, and social skills. Early implantation provides exposure to sounds that can be helpful during the critical period when children learn speech and language skills. In 2000, the Food and Drug Administration lowered the age of eligibility to 12 months for one type of CI. With regard to the results after cochlear implantation in relation to early implantation, better linguistic results are reported in children implanted before 12 months of life, even if no sufficient data exist regarding the relation between this advantage and the duration of implant use and how long

  14. Similarities and differences in coatings for magnesium-based stents and orthopaedic implants

    Directory of Open Access Journals (Sweden)

    Jun Ma

    2014-07-01

    Full Text Available Magnesium (Mg-based biodegradable materials are promising candidates for the new generation of implantable medical devices, particularly cardiovascular stents and orthopaedic implants. Mg-based cardiovascular stents represent the most innovative stent technology to date. However, these products still do not fully meet clinical requirements with regards to fast degradation rates, late restenosis, and thrombosis. Thus various surface coatings have been introduced to protect Mg-based stents from rapid corrosion and to improve biocompatibility. Similarly, different coatings have been used for orthopaedic implants, e.g., plates and pins for bone fracture fixation or as an interference screw for tendon-bone or ligament-bone insertion, to improve biocompatibility and corrosion resistance. Metal coatings, nanoporous inorganic coatings and permanent polymers have been proved to enhance corrosion resistance; however, inflammation and foreign body reactions have also been reported. By contrast, biodegradable polymers are more biocompatible in general and are favoured over permanent materials. Drugs are also loaded with biodegradable polymers to improve their performance. The key similarities and differences in coatings for Mg-based stents and orthopaedic implants are summarized.

  15. Fabrication of a Biologically-Implantable, Multiplexed, Multielectrode Array of JFETS for Cortical Implantation.

    Science.gov (United States)

    1984-12-01

    which could be implanted at the surface of the brain. Electrodes of microfine dimensions I-1 . ..6...to check the operation of the diffusion furnace oxidation tube by comparing measured thicknesses of the oxide against calculated values. Oxide Growth...faster rate than that of Eq ), (11-2). Initial adjustments made prior to using the diffusion furnace included: (1) profiling the oxidation tube to

  16. Low elastic modulus Ti-Ta alloys for load-bearing permanent implants: enhancing the biodegradation resistance by electrochemical surface engineering.

    Science.gov (United States)

    Kesteven, Jazmin; Kannan, M Bobby; Walter, Rhys; Khakbaz, Hadis; Choe, Han-Choel

    2015-01-01

    In this study, the in vitro degradation behaviour of titanium-tantalum (Ti-Ta) alloys (10-30 wt.% Ta) was investigated and compared with conventional implant materials, i.e., commercially pure titanium (Cp-Ti) and titanium-aluminium-vanadium (Ti6Al4V) alloy. Among the three Ti-Ta alloys studied, the Ti20Ta (6.3×10(-4) mm/y) exhibited the lowest degradation rate, followed by Ti30Ta (1.2×10(-3) mm/y) and Ti10Ta (1.4×10(-3) mm/y). All the Ti-Ta alloys exhibited lower degradation rate than that of Cp-Ti (1.8×10(-3) mm/y), which suggests that Ta addition to Ti is beneficial. As compared to Ti6Al4V alloy (8.1×10(-4) mm/y), the degradation rate of Ti20Ta alloy was lower by ~22%. However, the Ti30Ta alloy, which has closer elastic modulus to that of natural bone, showed ~48% higher degradation rate than that of Ti6Al4V alloy. Hence, to improve the degradation performance of Ti30Ta alloy, an intermediate thin porous layer was formed electrochemically on the alloy followed by calcium phosphate (CaP) electrodeposition. The coated Ti30Ta alloy (3.8×10(-3) mm/y) showed ~53% lower degradation rate than that of Ti6Al4V alloy. Thus, the study suggests that CaP coated Ti30Ta alloy can be a viable material for load-bearing permanent implants. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Pathological differences in radical prostatectomy specimens between low- and intermediate-risk prostate cancer patients. Indications for permanent seed implantation monotherapy

    International Nuclear Information System (INIS)

    Sakamoto, Naotaka; Monji, Keisuke; Yuuki, Kohei; Yoshikawa, Masahiro; Iguchi, Atsushi

    2010-01-01

    To clarify the indications for permanent seed implantation monotherapy in patients with intermediate-risk prostate cancer, pathological differences in radical prostatectomy specimens between low- and intermediate-risk prostate cancer were assessed. Fifty-three cases in the low-risk group and 96 cases in the intermediate-risk group had their radical prostatectomy specimens pathologically evaluated between April 2000 and January 2009. Patients with radical prostatectomy specimens of pT2 and Gleason score ≤3+4 were defined as the favorable group, while those with ≥pT3a and/or Gleason score ≥4+3 were defined as the unfavorable group. The favorable group was made up of 67.9%, 81.2%, 73.9%, 73.3%, 23.5% and 24.0% low-risk group cases, ≤T2a, GS 3+3 and 10< prostatic specific antigen (PSA)≤20 ng/ml cases, ≤T2a, GS 3+4 and PSA ≤10 ng/ml cases, ≤T2a, GS 3+4 and 10< PSA≤20 ng/ml cases, ≤T2a, GS 4+3 and PSA ≤20 ng/ml cases and T2b, GS ≤4+3 and PSA ≤20 ng/ml cases, respectively. The rate of unfavorable group in cases with ≤T2a, GS 4+3 and PSA ≤20 ng/ml, and cases with T2b, GS ≤4+3 and PSA ≤20 ng/ml was statistically higher than that in the low-risk group. Accordingly, cancer volume in cases with T2b, GS ≤4+3 and PSA ≤ 20 ng/ml was statistically larger than that in the low-risk group. Cancer volume in intermediate-risk groups other than ≤T2a, GS 3+4 and PSA ≤10 ng/ml tended to be larger than that in the low-risk group. As for radical prostatectomy specimens, the pathological findings of cases with ≤T2a, GS 3+4 and PSA ≤10 ng/ml were similar to those of cases in the low-risk group. The outcome for permanent seed implantation monotherapy with a conventional dose in cases with ≤T2a, GS 3+4 and PSA ≤10 ng/ml may be similar to that of cases in the low-risk group from a pathological aspect. (author)

  18. Biologically effective dose (BED) for interstitial seed implants containing a mixture of radionuclides with different half-lives

    International Nuclear Information System (INIS)

    Chen Zhe; Nath, Ravinder

    2003-01-01

    Purpose: To develop a tool for evaluating interstitial seed implants that contain a mixture of radionuclides with different half-lives and to demonstrate its utility by examining the clinical implications of prescribing to an isodose surface for such an implant. Methods and Materials: A linear-quadratic model for continuous low dose rate irradiation was developed for permanent implants containing a mixture of radionuclides. Using a generalized equation for the biologically effective dose (BED), the effects of cell proliferation and sublethal damage repair were examined systematically for implants containing a mixture of radionuclides. A head-and-neck permanent seed implant that contained a mixture of 125 I and 103 Pd seeds was used to demonstrate the utility of the generalized BED. Results: An equation of BED for implants containing a mixture of radionuclides with different half-lives was obtained. In such an implant, the effective cell kill was shown to depend strongly on the relative dose contributions from each radionuclide type; dose delivered by radionuclides with shorter half-life always resulted in more cell kill for any given sublethal damage repair and cell proliferation rates. Application of the BED formula to an implant containing a mixture of 125 I and 103 Pd seeds demonstrates that the conventional dose prescription to an isodose surface is not unique for such an implant. When the prescription dose was based on existing clinical experience of using 125 I seeds alone, mixing 103 Pd seeds with 125 I seeds would increase the cell kill. On the other hand, if the prescription dose were based on existing clinical experience of using 103 Pd seeds alone, mixing 125 I seeds with 103 Pd seeds in the same implant would create radiobiologically 'cold' spots (i.e., an increase in cell survival) at locations where a major portion of the prescription dose is contributed by the 125 I seeds. For fast-growing tumors, these 'cold' spots can become significant

  19. Follow-up of cochlear implant use in patients who developed bacterial meningitis following cochlear implantation.

    Science.gov (United States)

    Mancini, Patrizia; D'Elia, Chiara; Bosco, Ersilia; De Seta, Elio; Panebianco, Valeria; Vergari, Valeria; Filipo, Roberto

    2008-08-01

    The present study is a long-term follow-up of speech perception outcomes and cochlear implant use in three cases of meningitis that occurred after cochlear implantation. Case series study. Study was performed on three children implanted with different models of Clarion devices, two of them with positioner. Recognition and comprehension were assessed via the Italian adaptation of GASP (TAP) test, and phonetically balanced bi-syllabic words in open-set. High resolution computed tomography scan acquisition was performed to obtain axial coronal and oblique multiplanar reconstructions of the cochlea. Two patients were affected by enlarged cochlear acqueduct and Mondini malformation the first carrying positioner. One patient had a normal cochlea, and the positioner could have been the main cause of bacterial spread. As a consequence of meningitis the child with normal cochlea and the other with enlarged vestibular acqueduct developed cochlear ossification, increased M-level and worsening of hearing outcomes. The child with Mondini malformation developed facial nerve stimulation. Contralateral implantation was performed in the first two patients. Bacterial meningitis occurring after cochlear implantation may induce cochlear ossification, facial nerve stimulation, and permanent or temporary loss of implant use. Planned follow-up with high resolution computed tomography and evaluation of M-levels could be useful prognostic tools in the management of these patients.

  20. Identification of complications in mastectomy with immediate reconstruction using tissue expanders and permanent implants for breast cancer patients.

    Science.gov (United States)

    Ota, Daisuke; Fukuuchi, Atsushi; Iwahira, Yoshiko; Kato, Takao; Takeuchi, Masashi; Okamoto, Joji; Nishi, Tsunehiro

    2016-05-01

    Since complications of postmastectomy breast reconstruction may reduce patient satisfaction, we investigated complications of reconstruction with tissue expanders (TEs), particularly surgical site infections requiring TE/permanent implant (PI) removal. A retrospective review was performed of 234 primary breast cancer patients undergoing 239 postmastectomy breast reconstructions with TEs/PIs from 1997 to 2009. Clinicopathological findings and postoperative complications, particularly infections, were analyzed. Data were analyzed by the Chi-square test and a multivariate logistic regression model. TE infection risk factors considered for model inclusion were excisional biopsy, (neo) adjuvant chemotherapy, lymph node resection, body mass index (BMI), simultaneous bilateral reconstructions, and seroma aspiration. Removal of TEs/PIs was observed in 15.5% (37/239) of reconstructions, and 18/37 underwent re-reconstructions. Of the 19/37 reconstructions that were not achieved completely, the most frequent reason was TE infection (11 reconstructions). The completion rate was 92% (220/239 reconstructions) and it was significantly higher in reconstructions without TE infection than with infection (96 vs. 54%, p breast reconstruction, prevention of TE infection plays a key role. We should reduce unnecessary seroma aspirations and delay elevation/exercise of the ipsilateral arm.

  1. Modiolus-Hugging Intracochlear Electrode Array with Shape Memory Alloy

    Directory of Open Access Journals (Sweden)

    Kyou Sik Min

    2013-01-01

    Full Text Available In the cochlear implant system, the distance between spiral ganglia and the electrodes within the volume of the scala tympani cavity significantly affects the efficiency of the electrical stimulation in terms of the threshold current level and spatial selectivity. Because the spiral ganglia are situated inside the modiolus, the central axis of the cochlea, it is desirable that the electrode array hugs the modiolus to minimize the distance between the electrodes and the ganglia. In the present study, we propose a shape-memory-alloy-(SMA- embedded intracochlear electrode which gives a straight electrode a curved modiolus-hugging shape using the restoration force of the SMA as triggered by resistive heating after insertion into the cochlea. An eight-channel ball-type electrode array is fabricated with an embedded titanium-nickel SMA backbone wire. It is demonstrated that the electrode array changes its shape in a transparent plastic human cochlear model. To verify the safe insertion of the electrode array into the human cochlea, the contact pressures during insertion at the electrode tip and the contact pressures over the electrode length after insertion were calculated using a 3D finite element analysis. The results indicate that the SMA-embedded electrode is functionally and mechanically feasible for clinical applications.

  2. Non-invasive method for selection of electrodes and stimulus parameters for FES applications with intrafascicular arrays

    Science.gov (United States)

    Dowden, B. R.; Frankel, M. A.; Normann, R. A.; Clark, G. A.

    2012-02-01

    High-channel-count intrafascicular electrode arrays provide comprehensive and selective access to the peripheral nervous system. One practical difficulty in using several electrode arrays to evoke coordinated movements in paralyzed limbs is the identification of the appropriate stimulation channels and stimulus parameters to evoke desired movements. Here we present the use of a six degree-of-freedom load cell placed under the foot of a feline to characterize the muscle activation produced by three 100-electrode Utah Slanted Electrode Arrays (USEAs) implanted into the femoral nerves, sciatic nerves, and muscular branches of the sciatic nerves of three cats. Intramuscular stimulation was used to identify the endpoint force directions produced by 15 muscles of the hind limb, and these directions were used to classify the forces produced by each intrafascicular USEA electrode as flexion or extension. For 451 USEA electrodes, stimulus intensities for threshold and saturation muscle forces were identified, and the 3D direction and linearity of the force recruitment curves were determined. Further, motor unit excitation independence for 198 electrode pairs was measured using the refractory technique. This study demonstrates the utility of 3D endpoint force monitoring as a simple and non-invasive metric for characterizing the muscle-activation properties of hundreds of implanted peripheral nerve electrodes, allowing for electrode and parameter selection for neuroprosthetic applications.

  3. PZT Thin-Film Micro Probe Device with Dual Top Electrodes

    Science.gov (United States)

    Luo, Chuan

    Lead zirconate titanate (PZT) thin-film actuators have been studied intensively for years because of their potential applications in many fields. In this dissertation, a PZT thin-film micro probe device is designed, fabricated, studied, and proven to be acceptable as an intracochlear acoustic actuator. The micro probe device takes the form of a cantilever with a PZT thin-film diaphragm at the tip of the probe. The tip portion of the probe will be implanted in cochlea later in animal tests to prove its feasibility in hearing rehabilitation. The contribution of the dissertation is three-fold. First, a dual top electrodes design, consisting of a center electrode and an outer electrode, is developed to improve actuation displacement of the PZT thin-film diaphragm. The improvement by the dual top electrodes design is studied via a finite element model. When the dimensions of the dual electrodes are optimized, the displacement of the PZT thin-film diaphragm increases about 30%. A PZT thin-film diaphragm with dual top electrodes is fabricated to prove the concept, and experimental results confirm the predictions from the finite element analyses. Moreover, the dual electrode design can accommodate presence of significant residual stresses in the PZT thin-film diaphragm by changing the phase difference between the two electrodes. Second, a PZT thin-film micro probe device is fabricated and tested. The fabrication process consists of PZT thin-film deposition and deep reactive ion etching (DRIE). The uniqueness of the fabrication process is an automatic dicing mechanism that allows a large number of probes to be released easily from the wafer. Moreover, the fabrication is very efficient, because the DRIE process will form the PZT thin-film diaphragm and the special dicing mechanism simultaneously. After the probes are fabricated, they are tested with various possible implantation depths (i.e., boundary conditions). Experimental results show that future implantation depths

  4. The design of and chronic tissue response to a composite nerve electrode with patterned stiffness

    Science.gov (United States)

    Freeberg, M. J.; Stone, M. A.; Triolo, R. J.; Tyler, D. J.

    2017-06-01

    Objective. As neural interfaces demonstrate success in chronic applications, a novel class of reshaping electrodes with patterned regions of stiffness will enable application to a widening range of anatomical locations. Patterning stiff regions and flexible regions of the electrode enables nerve reshaping while accommodating anatomical constraints of various implant locations ranging from peripheral nerves to spinal and autonomic plexi. Approach. Introduced is a new composite electrode enabling patterning of regions of various electrode mechanical properties. The initial demonstration of the composite’s capability is the composite flat interface nerve electrode (C-FINE). The C-FINE is constructed from a sandwich of patterned PEEK within layers of pliable silicone. The shape of the PEEK provides a desired pattern of stiffness: stiff across the width of the nerve to reshape the nerve, but flexible along its length to allow for bending with the nerve. This is particularly important in anatomical locations near joints or organs, and in constrained compartments. We tested pressure and volume design constraints in vitro to verify that the C-FINE can attain a safe cuff-to-nerve ratio (CNR) without impeding intraneural blood flow. We measured nerve function as well as nerve and axonal morphology following 3 month implantation of the C-FINE without wires on feline peripheral nerves in anatomically constrained areas near mobile joints and major blood vessels in both the hind and fore limbs. Main Results. In vitro inflation tests showed effective CNRs (1.93  ±  0.06) that exceeded the industry safety standard of 1.5 at an internal pressure of 20 mmHg. This is less than the 30 mmHg shown to induce loss of conduction or compromise blood flow. Implanted cats showed no changes in physiology or electrophysiology. Behavioral signs were normal suggesting healthy nerves. Motor nerve conduction velocity and compound motor action potential did not change significantly

  5. Bioelectric analyses of an osseointegrated intelligent implant design system for amputees.

    Science.gov (United States)

    Isaacson, Brad M; Stinstra, Jeroen G; MacLeod, Rob S; Webster, Joseph B; Beck, James P; Bloebaum, Roy D

    2009-07-15

    The projected number of American amputees is expected to rise to 3.6 million by 2050. Many of these individuals depend on artificial limbs to perform routine activities, but prosthetic suspensions using traditional socket technology can prove to be cumbersome and uncomfortable for a person with limb loss. Moreover, for those with high proximal amputations, limited residual limb length may prevent exoprosthesis attachment all together. Osseointegrated implant technology is a novel operative procedure which allows firm skeletal attachment between the host bone and an implant. Preliminary results in European amputees with osseointegrated implants have shown improved clinical outcomes by allowing direct transfer of loads to the bone-implant interface. Despite the apparent advantages of osseointegration over socket technology, the current rehabilitation procedures require long periods of restrictive load bearing prior which may be reduced with expedited skeletal attachment via electrical stimulation. The goal of the osseointegrated intelligent implant design (OIID) system is to make the implant part of an electrical system to accelerate skeletal attachment and help prevent periprosthetic infection. To determine optimal electrode size and placement, we initiated proof of concept with computational modeling of the electric fields and current densities that arise during electrical stimulation of amputee residual limbs. In order to provide insure patient safety, subjects with retrospective computed tomography scans were selected and three dimensional reconstructions were created using customized software programs to ensure anatomical accuracy (Seg3D and SCIRun) in an IRB and HIPAA approved study. These software packages supported the development of patient specific models and allowed for interactive manipulation of electrode position and size. Preliminary results indicate that electric fields and current densities can be generated at the implant interface to achieve the

  6. Intraoperative Cochlear Implant Device Testing Utilizing an Automated Remote System: A Prospective Pilot Study.

    Science.gov (United States)

    Lohmann, Amanda R; Carlson, Matthew L; Sladen, Douglas P

    2018-03-01

    Intraoperative cochlear implant device testing provides valuable information regarding device integrity, electrode position, and may assist with determining initial stimulation settings. Manual intraoperative device testing during cochlear implantation requires the time and expertise of a trained audiologist. The purpose of the current study is to investigate the feasibility of using automated remote intraoperative cochlear implant reverse telemetry testing as an alternative to standard testing. Prospective pilot study evaluating intraoperative remote automated impedance and Automatic Neural Response Telemetry (AutoNRT) testing in 34 consecutive cochlear implant surgeries using the Intraoperative Remote Assistant (Cochlear Nucleus CR120). In all cases, remote intraoperative device testing was performed by trained operating room staff. A comparison was made to the "gold standard" of manual testing by an experienced cochlear implant audiologist. Electrode position and absence of tip fold-over was confirmed using plain film x-ray. Automated remote reverse telemetry testing was successfully completed in all patients. Intraoperative x-ray demonstrated normal electrode position without tip fold-over. Average impedance values were significantly higher using standard testing versus CR120 remote testing (standard mean 10.7 kΩ, SD 1.2 vs. CR120 mean 7.5 kΩ, SD 0.7, p automated testing with regard to the presence of open or short circuits along the array. There were, however, two cases in which standard testing identified an open circuit, when CR120 testing showed the circuit to be closed. Neural responses were successfully obtained in all patients using both systems. There was no difference in basal electrode responses (standard mean 195.0 μV, SD 14.10 vs. CR120 194.5 μV, SD 14.23; p = 0.7814); however, more favorable (lower μV amplitude) results were obtained with the remote automated system in the apical 10 electrodes (standard 185.4 μV, SD 11.69 vs. CR

  7. Electric Current Transmission Through Tissues of the Vestibular Labyrinth of a Patient: Perfection of the Vestibular Implant

    Science.gov (United States)

    Demkin, V. P.; Shchetinin, P. P.; Melnichuk, S. V.; Kingma, H.; Van de Berg, R.; Pleshkov, M. O.; Starkov, D. N.

    2018-03-01

    An electric model of current transmission through tissues of the vestibular labyrinth of a patient is suggested. To stimulate directly the vestibular nerve in surgical operation, terminations of the electrodes are implanted through the bone tissue of the labyrinth into the perilymph in the vicinity of the vestibular nerve. The biological tissue of the vestibular labyrinth surrounding the electrodes and having heterogeneous composition possesses conductive and dielectric properties. Thus, when a current pulse from the vestibular implant is applied to one of the electrodes, conductive disturbance currents may arise between the electrodes and the vestibular nerves that can significantly deteriorate the direct signal quality. To study such signals and to compensate for the conductive disturbance currents, an equivalent electric circuit with actual electric impedance properties of tissues of the vestibular system is suggested, and the time parameters of the conductive disturbance current transmission are calculated. It is demonstrated that these parameters can reach large values. The suggested electric model and the results of calculations can be used for perfection of the vestibular implant.

  8. Implantable Biosensors for Real-time Strain and Pressure Monitoring

    Directory of Open Access Journals (Sweden)

    Keat Ghee Ong

    2008-10-01

    Full Text Available Implantable biosensors were developed for real-time monitoring of pressure and strain in the human body. The sensors, which are wireless and passive, consisted of a soft magnetic material and a permanent magnet. When exposed to a low frequency AC magnetic field, the soft magnetic material generated secondary magnetic fields that also included the higher-order harmonic modes. Parameters of interest were determined by measuring the changes in the pattern of these higher-order harmonic fields, which was achieved by changing the intensity of a DC magnetic field generated by a permanent magnet. The DC magnetic field, or the biasing field, was altered by changing the separation distance between the soft magnetic material and the permanent magnet. For pressure monitoring, the permanent magnet was placed on the membrane of an airtight chamber. Changes in the ambient pressure deflected the membrane, altering the separation distance between the two magnetic elements and thus the higher-order harmonic fields. Similarly, the soft magnetic material and the permanent magnet were separated by a flexible substrate in the stress/strain sensor. Compressive and tensile forces flexed the substrate, changing the separation distance between the two elements and the higher-order harmonic fields. In the current study, both stress/strain and pressure sensors were fabricated and characterized. Good stability, linearity and repeatability of the sensors were demonstrated. This passive and wireless sensor technology may be useful for long term detection of physical quantities within the human body as a part of treatment assessment, disease diagnosis, or detection of biomedical implant failures.

  9. Dosimetric and radiobiological comparison of volumetric modulated arc therapy, high-dose rate brachytherapy, and low-dose rate permanent seeds implant for localized prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Ruijie, E-mail: ruijyang@yahoo.com; Zhao, Nan; Liao, Anyan; Wang, Hao; Qu, Ang

    2016-10-01

    To investigate the dosimetric and radiobiological differences among volumetric modulated arc therapy (VMAT), high-dose rate (HDR) brachytherapy, and low-dose rate (LDR) permanent seeds implant for localized prostate cancer. A total of 10 patients with localized prostate cancer were selected for this study. VMAT, HDR brachytherapy, and LDR permanent seeds implant plans were created for each patient. For VMAT, planning target volume (PTV) was defined as the clinical target volume plus a margin of 5 mm. Rectum, bladder, urethra, and femoral heads were considered as organs at risk. A 78 Gy in 39 fractions were prescribed for PTV. For HDR and LDR plans, the dose prescription was D{sub 90} of 34 Gy in 8.5 Gy per fraction, and 145 Gy to clinical target volume, respectively. The dose and dose volume parameters were evaluated for target, organs at risk, and normal tissue. Physical dose was converted to dose based on 2-Gy fractions (equivalent dose in 2 Gy per fraction, EQD{sub 2}) for comparison of 3 techniques. HDR and LDR significantly reduced the dose to rectum and bladder compared with VMAT. The D{sub mean} (EQD{sub 2}) of rectum decreased 22.36 Gy in HDR and 17.01 Gy in LDR from 30.24 Gy in VMAT, respectively. The D{sub mean} (EQD{sub 2}) of bladder decreased 6.91 Gy in HDR and 2.53 Gy in LDR from 13.46 Gy in VMAT. For the femoral heads and normal tissue, the mean doses were also significantly reduced in both HDR and LDR compared with VMAT. For the urethra, the mean dose (EQD{sub 2}) was 80.26, 70.23, and 104.91 Gy in VMAT, HDR, and LDR brachytherapy, respectively. For localized prostate cancer, both HDR and LDR brachytherapy were clearly superior in the sparing of rectum, bladder, femoral heads, and normal tissue compared with VMAT. HDR provided the advantage in sparing of urethra compared with VMAT and LDR.

  10. Dosimetric and radiobiological comparison of volumetric modulated arc therapy, high-dose rate brachytherapy, and low-dose rate permanent seeds implant for localized prostate cancer

    International Nuclear Information System (INIS)

    Yang, Ruijie; Zhao, Nan; Liao, Anyan; Wang, Hao; Qu, Ang

    2016-01-01

    To investigate the dosimetric and radiobiological differences among volumetric modulated arc therapy (VMAT), high-dose rate (HDR) brachytherapy, and low-dose rate (LDR) permanent seeds implant for localized prostate cancer. A total of 10 patients with localized prostate cancer were selected for this study. VMAT, HDR brachytherapy, and LDR permanent seeds implant plans were created for each patient. For VMAT, planning target volume (PTV) was defined as the clinical target volume plus a margin of 5 mm. Rectum, bladder, urethra, and femoral heads were considered as organs at risk. A 78 Gy in 39 fractions were prescribed for PTV. For HDR and LDR plans, the dose prescription was D 90 of 34 Gy in 8.5 Gy per fraction, and 145 Gy to clinical target volume, respectively. The dose and dose volume parameters were evaluated for target, organs at risk, and normal tissue. Physical dose was converted to dose based on 2-Gy fractions (equivalent dose in 2 Gy per fraction, EQD 2 ) for comparison of 3 techniques. HDR and LDR significantly reduced the dose to rectum and bladder compared with VMAT. The D mean (EQD 2 ) of rectum decreased 22.36 Gy in HDR and 17.01 Gy in LDR from 30.24 Gy in VMAT, respectively. The D mean (EQD 2 ) of bladder decreased 6.91 Gy in HDR and 2.53 Gy in LDR from 13.46 Gy in VMAT. For the femoral heads and normal tissue, the mean doses were also significantly reduced in both HDR and LDR compared with VMAT. For the urethra, the mean dose (EQD 2 ) was 80.26, 70.23, and 104.91 Gy in VMAT, HDR, and LDR brachytherapy, respectively. For localized prostate cancer, both HDR and LDR brachytherapy were clearly superior in the sparing of rectum, bladder, femoral heads, and normal tissue compared with VMAT. HDR provided the advantage in sparing of urethra compared with VMAT and LDR.

  11. [Strategy for minimally invasive cochlear implantation and residual hearing preservation].

    Science.gov (United States)

    Huang, Y Y; Chen, J Y; Shen, M; Yang, J

    2018-01-07

    In the past few decades, considerable development was achieved in the cochlear implantation following the emergence of innovative electrode array and advances in minimally invasive surgery. Minimally invasive technique led to a better preservation of residual low-frequency hearing. The loss of residual hearing was caused by complicated factors. According to previous studies, a slower and stable speed of electrode insertion and the use of perioperative steroids were demonstrated to have a positive impact on hearing preservation. The selection of electrode array or its insertion approaches didn't show any distinctive benefits in hearing preservation.

  12. Design, construction and mechanical optimisation process of electrode with radial current flow in the scala tympani.

    Science.gov (United States)

    Deman, P R; Kaiser, T M; Dirckx, J J; Offeciers, F E; Peeters, S A

    2003-09-30

    A 48 contact cochlear implant electrode has been constructed for electrical stimulation of the auditory nerve. The stimulating contacts of this electrode are organised in two layers: 31 contacts on the upper surface directed towards the habenula perforata and 17 contacts connected together as one longitudinal contact on the underside. The design of the electrode carrier aims to make radial current flow possible in the cochlea. The mechanical structure of the newly designed electrode was optimised to obtain maximal insertion depth. Electrode insertion tests were performed in a transparent acrylic model of the human cochlea.

  13. An Implantable Versatile Electrode-Driving ASIC for Chronic Epidural Stimulation in Rats.

    Science.gov (United States)

    Giagka, Vasiliki; Eder, Clemens; Donaldson, Nick; Demosthenous, Andreas

    2015-06-01

    This paper presents the design and testing of an electrode driving application specific integrated circuit (ASIC) intended for epidural spinal cord electrical stimulation in rats. The ASIC can deliver up to 1 mA fully programmable monophasic or biphasic stimulus current pulses, to 13 electrodes selected in any possible configuration. It also supports interleaved stimulation. Communication is achieved via only 3 wires. The current source and the control of the stimulation timing were kept off-chip to reduce the heat dissipation close to the spinal cord. The ASIC was designed in a 0.18- μm high voltage CMOS process. Its output voltage compliance can be up to 25 V. It features a small core area (ASIC was developed to be suitable for integration on the epidural electrode array, and two different versions were fabricated and electrically tested. Results from both versions were almost indistinguishable. The performance of the system was verified for different loads and stimulation parameters. Its suitability to drive a passive epidural 12-electrode array in saline has also been demonstrated.

  14. Charge sharing in multi-electrode devices for deterministic doping studied by IBIC

    International Nuclear Information System (INIS)

    Jong, L.M.; Newnham, J.N.; Yang, C.; Van Donkelaar, J.A.; Hudson, F.E.; Dzurak, A.S.; Jamieson, D.N.

    2011-01-01

    Following a single ion strike in a semiconductor device the induced charge distribution changes rapidly with time and space. This phenomenon has important applications to the sensing of ionizing radiation with applications as diverse as deterministic doping in semiconductor devices to radiation dosimetry. We have developed a new method for the investigation of this phenomenon by using a nuclear microprobe and the technique of Ion Beam Induced Charge (IBIC) applied to a specially configured sub-100 μm scale silicon device fitted with two independent surface electrodes coupled to independent data acquisition systems. The separation between the electrodes is comparable to the range of the 2 MeV He ions used in our experiments. This system allows us to integrate the total charge induced in the device by summing the signals from the independent electrodes and to measure the sharing of charge between the electrodes as a function of the ion strike location as a nuclear microprobe beam is scanned over the sensitive region of the device. It was found that for a given ion strike location the charge sharing between the electrodes allowed the beam-strike location to be determined to higher precision than the probe resolution. This result has potential application to the development of a deterministic doping technique where counted ion implantation is used to fabricate devices that exploit the quantum mechanical attributes of the implanted ions.

  15. [Cochlear implant in patients with congenital malformation of inner ear].

    Science.gov (United States)

    Han, Dong-yi; Wu, Wen-ming; Xi, Xin; Huang, De-liang; Yang, Wei-yan

    2004-02-01

    To study surgical difficulty and key of the cochlear implant in patients with congenital malformation of inner ear. The cochlear implantations were performed in our department from Jan. 2001 to Apr. 2003 for 18 patients with the malformation of inner ear. In this series, there were 11 cases of large vestibular aqueduct syndrome (LVAS), 3 cases of Waardenberg syndrome, 3 cases of Mondini malformation, and 1 case of Usher syndrome. All 18 patients accepted the Nucleus 24-channel cochlear implantations, including Nucleus straight electrode in 13 cases but Contour implantation in 5 cases of LVAS. During operations, leakage of perilymph but not cerebrospinal fluid (CSF) from the open of scala tympani occurred in 11 cases of LVAS, however, the electrode was inserted successfully. The abnormalities of round window occurred in one of 3 cases of Waardenberg syndrome and 3 cases of Mondini malformation, respectively. The cochlear implant could be conducted successfully for the LVAS, and the postoperative effect was same as the ones for the deafness persons with normal development of inner ear. However, for the patients with Mondini syndrome and common cavity, it is important to accurately assess the extent of abnormalities in the inner ear and accompanied malformation before operation, and to evaluate the full extent of difficulties of the operation in order to minimize the risk of CSF leakage and meningitis.

  16. A comparative study of zirconium and titanium implants in rat: osseointegration and bone material quality.

    Science.gov (United States)

    Hoerth, Rebecca M; Katunar, María R; Gomez Sanchez, Andrea; Orellano, Juan C; Ceré, Silvia M; Wagermaier, Wolfgang; Ballarre, Josefina

    2014-02-01

    Permanent metal implants are widely used in human medical treatments and orthopedics, for example as hip joint replacements. They are commonly made of titanium alloys and beyond the optimization of this established material, it is also essential to explore alternative implant materials in view of improved osseointegration. The aim of our study was to characterize the implant performance of zirconium in comparison to titanium implants. Zirconium implants have been characterized in a previous study concerning material properties and surface characteristics in vitro, such as oxide layer thickness and surface roughness. In the present study, we compare bone material quality around zirconium and titanium implants in terms of osseointegration and therefore characterized bone material properties in a rat model using a multi-method approach. We used light and electron microscopy, micro Raman spectroscopy, micro X-ray fluorescence and X-ray scattering techniques to investigate the osseointegration in terms of compositional and structural properties of the newly formed bone. Regarding the mineralization level, the mineral composition, and the alignment and order of the mineral particles, our results show that the maturity of the newly formed bone after 8 weeks of implantation is already very high. In conclusion, the bone material quality obtained for zirconium implants is at least as good as for titanium. It seems that the zirconium implants can be a good candidate for using as permanent metal prosthesis for orthopedic treatments.

  17. Analysis of electrically evoked compound action potential of the auditory nerve in children with bilateral cochlear implants.

    Science.gov (United States)

    Caldas, Fernanda Ferreira; Cardoso, Carolina Costa; Barreto, Monique Antunes de Souza Chelminski; Teixeira, Marina Santos; Hilgenberg, Anacléia Melo da Silva; Serra, Lucieny Silva Martins; Bahmad Junior, Fayez

    2016-01-01

    The cochlear implant device has the capacity to measure the electrically evoked compound action potential of the auditory nerve. The neural response telemetry is used in order to measure the electrically evoked compound action potential of the auditory nerve. To analyze the electrically evoked compound action potential, through the neural response telemetry, in children with bilateral cochlear implants. This is an analytical, prospective, longitudinal, historical cohort study. Six children, aged 1-4 years, with bilateral cochlear implant were assessed at five different intervals during their first year of cochlear implant use. There were significant differences in follow-up time (p=0.0082) and electrode position (p=0.0019) in the T-NRT measure. There was a significant difference in the interaction between time of follow-up and electrode position (p=0.0143) when measuring the N1-P1 wave amplitude between the three electrodes at each time of follow-up. The electrically evoked compound action potential measurement using neural response telemetry in children with bilateral cochlear implants during the first year of follow-up was effective in demonstrating the synchronized bilateral development of the peripheral auditory pathways in the studied population. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  18. Implantable biochemical fuel cell. [German patent

    Energy Technology Data Exchange (ETDEWEB)

    Richter, G; Rao, J R

    1978-09-14

    Implantable biochemical fuel cells for the operation of heart pacemakers or artificial hearts convert oxidisable body substances such as glucose on the anode side and reduce the oxygen contained in body fluids at the cathode. The anode and cathode are separated by membranes which are impermeable to albumen and blood corpuscles in body fluids. A chemical shortcircuit cannot occur in practice if, according to the invention, one or more selective oxygen electrodes with carbon as catalyst are arranged so that the mixture which diffuses into the cell from body fluids during operation reaches the fuel cell electrode through the porous oxygen electrode. The membranes used must be permeable to water. Cellulose, polymerised polyvinyl alcohol or an ion exchanger with a buffering capacity between pH5 and 8 act as permeable materials.

  19. Sci-Thur PM – Brachytherapy 02: Positional accuracy in Pd-103 permanent breast seed implant (PBSI) brachytherapy at the Tom Baker Cancer Centre (TBCC)

    Energy Technology Data Exchange (ETDEWEB)

    Frederick, Amy; Watt, Elizabeth; Peacock, Michael; Husain, Siraj; Meyer, Tyler; Roumeliotis, Michael [University of Calgary, Tom Baker Cancer Centre (Canada)

    2016-08-15

    Purpose: This retrospective study aims to quantify the positional accuracy of seed delivery in permanent breast seed implant (PBSI) brachytherapy at the Tom Baker Cancer Centre (TBCC). Methods: Treatment planning and post-implant CT scans for 5 patients were rigidly registered using the MIM Symphony™ software (MIM Software, Cleveland, OH) and used to evaluate differences between planned and implanted seed positions. Total and directional seed displacements were calculated for each patient in a clinically relevant ‘needle coordinate system’, defined relative to the angle of fiducial needle insertion. Results: The overall average total seed displacement was 10±8 mm. Systematic seed displacements were observed in individual patients and the magnitude and direction of these offsets varied among patients. One patient showed a significant directional seed displacement in the shallow-deep direction compared with the other four patients. With the exception of this one patient outlier, no significant systematic directional displacements in the needle coordinate system were observed for this cohort; the average directional displacements were −1±5 mm, 2±3 mm, and −2±4 mm in the shallow-deep, up-down, and right-left directions respectively. Conclusion: With the exception of one patient outlier, the magnitude of seed displacements were relatively consistent among patients. The results indicate that the shallow-deep direction possesses the largest uncertainty for the seed delivery method used at the TBCC. The relatively large uncertainty in seed placement in this direction is expected, as this is the direction of needle insertion. Further work will involve evaluating deflections of delivered needle tracks from their planned positions.

  20. A wide-field suprachoroidal retinal prosthesis is stable and well tolerated following chronic implantation.

    Science.gov (United States)

    Villalobos, Joel; Nayagam, David A X; Allen, Penelope J; McKelvie, Penelope; Luu, Chi D; Ayton, Lauren N; Freemantle, Alexia L; McPhedran, Michelle; Basa, Meri; McGowan, Ceara C; Shepherd, Robert K; Williams, Chris E

    2013-05-01

    The safety of chronic implantation of a retinal prosthesis in the suprachoroidal space has not been established. This study aimed to determine the safety of a wide-field suprachoroidal electrode array following chronic implantation using histopathologic techniques and electroretinography. A platinum electrode array in a wide silicone substrate was implanted unilaterally in the suprachoroidal space in adult cats (n = 7). The lead and connector were tunneled out of the orbit and positioned subcutaneously. Postsurgical recovery was assessed using fundus photography and electroretinography (ERG). Following 3 months of passive implantation, the animals were terminated and the eyes assessed for the pathologic response to implantation. The implant was mechanically stable in the suprachoroidal space during the course of the study. The implanted eye showed a transient increase in ERG response amplitude at 2 weeks, which returned to normal by 3 months. Pigmentary changes were observed at the distal end of the implant, near the optic disc. Histopathologic assessment revealed a largely intact retina and a thin fibrous capsule around the suprachoroidal implant cavity. The foreign body response was minimal, with sporadic presence of macrophages and no active inflammation. All implanted eyes were negative for bacterial or fungal infections. A midgrade granuloma and thick fibrous buildup surrounded the extraocular cable. Scleral closure was maintained in six of seven eyes. There were no staphylomas or choroidal incarceration. A wide-field retinal prosthesis was stable and well tolerated during long-term suprachoroidal implantation in a cat model. The surgical approach was reproducible and overall safe.

  1. A Binaural CI Research Platform for Oticon Medical SP/XP Implants Enabling ITD/ILD and Variable Rate Processing

    Science.gov (United States)

    Adiloğlu, K.; Herzke, T.

    2015-01-01

    We present the first portable, binaural, real-time research platform compatible with Oticon Medical SP and XP generation cochlear implants. The platform consists of (a) a pair of behind-the-ear devices, each containing front and rear calibrated microphones, (b) a four-channel USB analog-to-digital converter, (c) real-time PC-based sound processing software called the Master Hearing Aid, and (d) USB-connected hardware and output coils capable of driving two implants simultaneously. The platform is capable of processing signals from the four microphones simultaneously and producing synchronized binaural cochlear implant outputs that drive two (bilaterally implanted) SP or XP implants. Both audio signal preprocessing algorithms (such as binaural beamforming) and novel binaural stimulation strategies (within the implant limitations) can be programmed by researchers. When the whole research platform is combined with Oticon Medical SP implants, interaural electrode timing can be controlled on individual electrodes to within ±1 µs and interaural electrode energy differences can be controlled to within ±2%. Hence, this new platform is particularly well suited to performing experiments related to interaural time differences in combination with interaural level differences in real-time. The platform also supports instantaneously variable stimulation rates and thereby enables investigations such as the effect of changing the stimulation rate on pitch perception. Because the processing can be changed on the fly, researchers can use this platform to study perceptual changes resulting from different processing strategies acutely. PMID:26721923

  2. A Binaural CI Research Platform for Oticon Medical SP/XP Implants Enabling ITD/ILD and Variable Rate Processing.

    Science.gov (United States)

    Backus, B; Adiloğlu, K; Herzke, T

    2015-12-30

    We present the first portable, binaural, real-time research platform compatible with Oticon Medical SP and XP generation cochlear implants. The platform consists of (a) a pair of behind-the-ear devices, each containing front and rear calibrated microphones, (b) a four-channel USB analog-to-digital converter, (c) real-time PC-based sound processing software called the Master Hearing Aid, and (d) USB-connected hardware and output coils capable of driving two implants simultaneously. The platform is capable of processing signals from the four microphones simultaneously and producing synchronized binaural cochlear implant outputs that drive two (bilaterally implanted) SP or XP implants. Both audio signal preprocessing algorithms (such as binaural beamforming) and novel binaural stimulation strategies (within the implant limitations) can be programmed by researchers. When the whole research platform is combined with Oticon Medical SP implants, interaural electrode timing can be controlled on individual electrodes to within ±1 µs and interaural electrode energy differences can be controlled to within ±2%. Hence, this new platform is particularly well suited to performing experiments related to interaural time differences in combination with interaural level differences in real-time. The platform also supports instantaneously variable stimulation rates and thereby enables investigations such as the effect of changing the stimulation rate on pitch perception. Because the processing can be changed on the fly, researchers can use this platform to study perceptual changes resulting from different processing strategies acutely. © The Author(s) 2015.

  3. Speech perception with mono- and quadrupolar electrode configurations: a crossover study.

    NARCIS (Netherlands)

    Mens, L.H.M.; Berenstein, C.K.

    2005-01-01

    OBJECTIVE: To study the effect of two multipolar electrode configurations on speech perception, pitch perception, and the intracochlear electrical field. STUDY DESIGN: Crossover design; within subject. SETTING: Tertiary referral center. PATIENTS: Eight experienced adult cochlear implant users.

  4. Simultaneous Bilateral Cochlear Implantation for a 6-Month Child with a History of Meningitis

    Directory of Open Access Journals (Sweden)

    Kh. M. Diab

    2015-01-01

    Full Text Available The article presents the first case of simultaneous bilateral cochlear implantation for a 6-month child with IV degree sensorineural hearing loss after meningocephalitis in Russia. Despite partial ossification of the cochlear basal turns, the early timing of implantation allowed to fully implant active electrodes to both ears. The simultaneous bilateral cochlear implantation in young children, who had meningitis, is a minimally invasive and highly efficient procedure with good long-term results of oral-aural after-care.

  5. Comparison of the HiFocus Mid-Scala and HiFocus 1J Electrode Array: Angular Insertion Depths and Speech Perception Outcomes.

    Science.gov (United States)

    van der Jagt, M Annerie; Briaire, Jeroen J; Verbist, Berit M; Frijns, Johan H M

    2016-01-01

    The HiFocus Mid-Scala (MS) electrode array has recently been introduced onto the market. This precurved design with a targeted mid-scalar intracochlear position pursues an atraumatic insertion and optimal distance for neural stimulation. In this study we prospectively examined the angular insertion depth achieved and speech perception outcomes resulting from the HiFocus MS electrode array for 6 months after implantation, and retrospectively compared these with the HiFocus 1J lateral wall electrode array. The mean angular insertion depth within the MS population (n = 96) was found at 470°. This was 50° shallower but more consistent than the 1J electrode array (n = 110). Audiological evaluation within a subgroup, including only postlingual, unilaterally implanted, adult cochlear implant recipients who were matched on preoperative speech perception scores and the duration of deafness (MS = 32, 1J = 32), showed no difference in speech perception outcomes between the MS and 1J groups. Furthermore, speech perception outcome was not affected by the angular insertion depth or frequency mismatch. © 2016 S. Karger AG, Basel.

  6. Silicon/SU8 multi-electrode micro-needle for in vivo neurochemical monitoring.

    Science.gov (United States)

    Vasylieva, Natalia; Marinesco, Stéphane; Barbier, Daniel; Sabac, Andrei

    2015-10-15

    Simultaneous monitoring of glucose and lactate is an important challenge for understanding brain energetics in physiological or pathological states. We demonstrate here a versatile method based on a minimally invasive single implantation in the rat brain. A silicon/SU8-polymer multi-sensing needle-shaped biosensor, was fabricated and tested. The multi-electrode array design comprises three platinum planar microelectrodes with a surface area of 40 × 200 µm(2) and a spacing of 200 µm, which were micromachined on a single 3mm long micro-needle having a 100 × 50 µm(2) cross-section for reduced tissue damage during implantation. Platinum micro-electrodes were aligned at the bottom of micro-wells obtained by photolithography on a SU8 photoresist layer. After clean room processing, each micro-electrode was functionalized inside the micro-wells by means of a micro-dispensing device, either with glucose oxidase or with lactate oxidase, which were cross-linked on the platinum electrodes. The third electrode covered with Bovine Serum Albumin (BSA) was used for the control of non-specific currents. The thick SU8 photoresist layer has revealed excellent electrical insulation of the micro-electrodes and between interconnection lines, and ensured a precise localization and packaging of the sensing enzymes on platinum micro-electrodes. During in vitro calibration with concentrations of analytes in the mM range, the micro-wells patterned in the SU8 photoresist proved to be highly effective in eliminating cross-talk signals, caused by H2O2 diffusion from closely spaced micro-electrodes. Moreover, our biosensor was successfully assayed in the rat cortex for simultaneous monitoring of both glucose and lactate during insulin and glucose administration. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Awake craniotomy for assisting placement of auditory brainstem implant in NF2 patients.

    Science.gov (United States)

    Zhou, Qiangyi; Yang, Zhijun; Wang, Zhenmin; Wang, Bo; Wang, Xingchao; Zhao, Chi; Zhang, Shun; Wu, Tao; Li, Peng; Li, Shiwei; Zhao, Fu; Liu, Pinan

    2018-06-01

    Auditory brainstem implants (ABIs) may be the only opportunity for patients with NF2 to regain some sense of hearing sensation. However, only a very small number of individuals achieved open-set speech understanding and high sentence scores. Suboptimal placement of the ABI electrode array over the cochlear nucleus may be one of main factors for poor auditory performance. In the current study, we present a method of awake craniotomy to assist with ABI placement. Awake surgery and hearing test via the retrosigmoid approach were performed for vestibular schwannoma resections and auditory brainstem implantations in four patients with NF2. Auditory outcomes and complications were assessed postoperatively. Three of 4 patients who underwent awake craniotomy during ABI surgery received reproducible auditory sensations intraoperatively. Satisfactory numbers of effective electrodes, threshold levels and distinct pitches were achieved in the wake-up hearing test. In addition, relatively few electrodes produced non-auditory percepts. There was no serious complication attributable to the ABI or awake craniotomy. It is safe and well tolerated for neurofibromatosis type 2 (NF2) patients using awake craniotomy during auditory brainstem implantation. This method can potentially improve the localization accuracy of the cochlear nucleus during surgery.

  8. Effect of electrode shape on grounding resistances - Part 2

    DEFF Research Database (Denmark)

    Tomaskovicova, Sonia; Ingeman-Nielsen, Thomas; Christiansen, Anders V.

    2016-01-01

    Although electric resistivity tomography (ERT) is now regarded as a standard tool in permafrost monitoring, high grounding resistances continue to limit the acquisition of time series over complete freeze-thaw cycles. In an attempt to alleviate the grounding resistance problem, we have tested three...... electrode designs featuring increasing sizes and surface area, in the laboratory and at three different field sites in Greenland. Grounding resistance measurements showed that changing the electrode shape (using plates instead of rods) reduced the grounding resistances at all sites by 28%-69% during...... unfrozen and frozen ground conditions. Using meshes instead of plates (the same rectangular shape and a larger effective surface area) further improved the grounding resistances by 29%-37% in winter. Replacement of rod electrodes of one entire permanent permafrost monitoring array by meshes resulted...

  9. Meningitis after cochlear implantation in Mondini malformation.

    Science.gov (United States)

    Page, E L; Eby, T L

    1997-01-01

    Although the potential for CSF leakage and subsequent meningitis after cochlear implantation in the malformed cochlea has been recognized, this complication has not been previously reported. We report a case of CSF otorhinorrhea and meningitis after minor head trauma developing 2 years after cochlear implantation in a child with Mondini malformation. Leakage of CSF was identified from the cochleostomy around the electrode of the implant, and this leak was sealed with a temporalis fascia and muscle plug. Although this complication appears to be rare, care must be taken to seal the cochleostomy in children with inner ear malformations at the initial surgery, and any episode of meningitis after surgery must be thoroughly investigated to rule out CSF leakage from the labyrinth.

  10. Intracochlear Position of Cochlear Implants Determined Using CT Scanning versus Fitting Levels: Higher Threshold Levels at Basal Turn.

    Science.gov (United States)

    van der Beek, Feddo B; Briaire, Jeroen J; van der Marel, Kim S; Verbist, Berit M; Frijns, Johan H M

    2016-01-01

    In this study, the effects of the intracochlear position of cochlear implants on the clinical fitting levels were analyzed. A total of 130 adult subjects who used a CII/HiRes 90K cochlear implant with a HiFocus 1/1J electrode were included in the study. The insertion angle and the distance to the modiolus of each electrode contact were determined using high-resolution CT scanning. The threshold levels (T-levels) and maximum comfort levels (M-levels) at 1 year of follow-up were determined. The degree of speech perception of the subjects was evaluated during routine clinical follow-up. The depths of insertion of all the electrode contacts were determined. The distance to the modiolus was significantly smaller at the basal and apical cochlear parts compared with that at the middle of the cochlea (p basal end of the cochlea (3.4 dB). Additionally, the M-levels, which were fitted in our clinic using a standard profile, also increased toward the basal end, although with a lower amplitude (1.3 dB). Accordingly, the dynamic range decreased toward the basal end (2.1 dB). No correlation was found between the distance to the modiolus and the T-level or the M-level. Furthermore, the correlation between the insertion depth and stimulation levels was not affected by the duration of deafness, age at implantation or the time since implantation. Additionally, the T-levels showed a significant correlation with the speech perception scores (p stimulation levels of the cochlear implants were affected by the intracochlear position of the electrode contacts, which were determined using postoperative CT scanning. Interestingly, these levels depended on the insertion depth, whereas the distance to the modiolus did not affect the stimulation levels. The T-levels increased toward the basal end of the cochlea. The level profiles were independent of the overall stimulation levels and were not affected by the biographical data of the patients, such as the duration of deafness, age at

  11. Correlation of mRNA Expression and Signal Variability in Chronic Intracortical Electrodes.

    Science.gov (United States)

    Falcone, Jessica D; Carroll, Sheridan L; Saxena, Tarun; Mandavia, Dev; Clark, Alexus; Yarabarla, Varun; Bellamkonda, Ravi V

    2018-01-01

    The goal for this research was to identify molecular mechanisms that explain animal-to-animal variability in chronic intracortical recordings. Microwire electrodes were implanted into Sprague Dawley rats at an acute (1 week) and a chronic (14 weeks) time point. Weekly recordings were conducted, and action potentials were evoked in the barrel cortex by deflecting the rat's whiskers. At 1 and 14 weeks, tissue was collected, and mRNA was extracted. mRNA expression was compared between 1 and 14 weeks using a high throughput multiplexed qRT-PCR. Pearson correlation coefficients were calculated between mRNA expression and signal-to-noise ratios at 14 weeks. At 14 weeks, a positive correlation between signal-to-noise ratio (SNR) and NeuN and GFAP mRNA expression was observed, indicating a relationship between recording strength and neuronal population, as well as reactive astrocyte activity. The inflammatory state around the electrode interface was evaluated using M1-like and M2-like markers. Expression for both M1-like and M2-like mRNA markers remained steady from 1 to 14 weeks. Anti-inflammatory markers, CD206 and CD163, however, demonstrated a significant positive correlation with SNR quality at 14 weeks. VE-cadherin, a marker for adherens junctions, and PDGFR-β, a marker for pericytes, both partial representatives of blood-brain barrier health, had a positive correlation with SNR at 14 weeks. Endothelial adhesion markers revealed a significant increase in expression at 14 weeks, while CD45, a pan-leukocyte marker, significantly decreased at 14 weeks. No significant correlation was found for either the endothelial adhesion or pan-leukocyte markers. A positive correlation between anti-inflammatory and blood-brain barrier health mRNA markers with electrophysiological efficacy of implanted intracortical electrodes has been demonstrated. These data reveal potential mechanisms for further evaluation to determine potential target mechanisms to improve

  12. A new cochlear implant electrode with a "cork"-type stopper for inner ear malformations.

    Science.gov (United States)

    Sennaroğlu, Levent; Atay, Gamze; Bajin, Münir Demir

    2014-08-01

    Gusher in inner ear malformations is common in patients with incomplete partition type I and type III. It is also common in less severe form as oozing in incomplete partition type II and large vestibular aqueduct. It is important to prevent cerebrospinal fluid (CSF) escape around the electrode to prevent meningitis. The custom-made device was produced by Med-El Company. It has a "cork"-like stopper instead of the usual silicon ring to prevent gusher. There are two types of electrodes of different lengths. The standard one is 25mm (contact space 1.7mm) and the short one is 20mm (contact space 1.3mm). It was used in 50 patients with different inner ear malformations. Thirteen patients had gusher, and 11 patients oozing during cochleostomy. One patient with initial prototype of the cork electrode had to be revised because of persistent oozing around the electrode. Another patient had slow extrusion of the electrode most probably due to CSF pulsation and had to be revised. Both patients had no more CSF fistula. CSF fistula in inner ear malformations is a serious situation which may lead to recurrent meningitis. The new electrode with "cork" stopper looks promising in preventing the postoperative CSF leak around the electrode. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  13. Moving toward focal therapy in prostate cancer: dual-isotope permanent seed implants as a possible solution.

    Science.gov (United States)

    Todor, Dorin A; Barani, Igor J; Lin, Peck-Sun; Anscher, Mitchell S

    2011-09-01

    To compare the ability of single- and dual-isotope prostate seed implants to escalate biologically effective dose (BED) to foci of disease while reducing prescription dose to the prostate. Nine plans, using 125I, 103Pd, and 131Cs alone and in combination were created retrospectively for 2 patients. Ultrasound and MRI/MRS datasets were used for treatment planning. Voxel-by-voxel BED was calculated for single- and dual-isotope plans. Equivalent uniform BED (EUBED) was used to compare plans. The MRS-positive planning target volumes (PTVi) were delineated along with PTV (prostate+5 mm), rectum, and urethra. Single-isotope implants, prescribed to conventional doses, were generated to achieve good PTV coverage. The PTVi were prospectively used to generate implants using mixtures of isotopes. For mixed-radioisotope implants, we also explored the impact on EUBED of lowering prescription doses by 15%. The EUBED of PTVi in the setting of primary 125I implant increased 20-66% when 103Pd and 131Cs were used compared with 125I boost. Decreasing prescription dose by 15% in mixed-isotope implants results in a potential 10% reduction in urethral EUBED with preservation of PTV coverage while still boosting PTVi (up to 80%). When radiobiologic parameters corresponding to more-aggressive disease are assigned to foci, faster-decaying isotopes used in mixed implants have the potential to preserve the equivalent biological effect of mono-isotope implants considering less-aggressive disease distributed in the entire prostate. This is a hypothesis-generating study proposing a treatment paradigm that could be the middle ground between whole-gland irradiation and focal-only treatment. The use of two isotopes concurrent with decreasing the minimal peripheral dose is shown to increase EUBED of selected subvolumes while preserving the therapeutic effect at the level of the gland. Copyright © 2011 Elsevier Inc. All rights reserved.

  14. Anaesthetic management of a patient with deep brain stimulation implant for radical nephrectomy

    Directory of Open Access Journals (Sweden)

    Monica Khetarpal

    2014-01-01

    Full Text Available A 63-year-old man with severe Parkinson′s disease (PD who had been implanted with deep brain stimulators into both sides underwent radical nephrectomy under general anaesthesia with standard monitoring. Deep brain stimulation (DBS is an alternative and effective treatment option for severe and refractory PD and other illnesses such as essential tremor and intractable epilepsy. Anaesthesia in the patients with implanted neurostimulator requires special consideration because of the interaction between neurostimulator and the diathermy. The diathermy can damage the brain tissue at the site of electrode. There are no standard guidelines for the anaesthetic management of a patient with DBS electrode in situ posted for surgery.

  15. Application of ion implantation RBS to the study of electrocatalysis

    International Nuclear Information System (INIS)

    Kelly, E.J.; Vallet, C.E.; White, C.W.

    1990-01-01

    Ir-implanted titanium near-surface alloys were prepared by ion implantation, characterized (Ir concentration/depth profiles) by Rutherford backscattering (RBS), and subsequently anodically oxidized to form electrocatalytically active Ir x Ti 1-x O 2 /Ti electrodes. The electrochemical behavior of the metallic-like Ir 4 Ti 1-x O 2 /Ti electrodes in acidic chloride, sulfate, and perchlorate solutions was investigated, and the results compared with those previously obtained with similarly prepared Ru x Ti 1-x O 2 /Ti electrodes. For both electrodes, M x Ti 1-x O 2 /Ti (M equals Ir or Ru), the Tafel slope for the Cl 2 evolution reaction is 40 mV, i.e.,δE/δlog i equals 2.303 (2RT/3F). The reaction order (n) with respect to chloride ion concentration δlogi/δlog[Cl - ] + 1, where K 9 equals 54.9 dm 3 mol -1 for Ir x Ti 1-x O 2 /Ti and K 9 equals 40 dm 3 mol -1 for Ru x Ti 1-x O 2 /Ti. A modified Volmer-Heyrovsky mechanism, one in which the role of absorbed chloride ions is taken into account, is shown to be consistent with aforementioned diagnostic parameters

  16. Carbon Nanofiber Electrode Array for Neurochemical Monitoring

    Science.gov (United States)

    Koehne, Jessica E.

    2017-01-01

    A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report using vertically aligned CNF as neurotransmitter recording electrodes for application in a smart deep brain stimulation (DBS) device. Our approach combines a multiplexed CNF electrode chip, developed at NASA Ames Research Center, with the Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS) system, developed at the Mayo Clinic. Preliminary results indicate that the CNF nanoelectrode arrays are easily integrated with WINCS for neurotransmitter detection in a multiplexed array format. In the future, combining CNF based stimulating and recording electrodes with WINCS may lay the foundation for an implantable smart therapeutic system that utilizes neurochemical feedback control while likely resulting in increased DBS application in various neuropsychiatric disorders. In total, our goal is to take advantage of the nanostructure of CNF arrays for biosensing studies requiring ultrahigh sensitivity, high-degree of miniaturization, and selective biofunctionalization.

  17. Dual chamber pacemaker implants - a new opportunity in Pakistan for children with congenital and acquired complete heart block

    International Nuclear Information System (INIS)

    Ashfaq, A.; Khan, M.A.; Atiq, M.

    2011-01-01

    Implantation of cardiac pacemakers has been practiced for at least five decades with continuous developments of the hardware. The invention of dual chamber pacemakers has initiated a debate concerning its superiority over single chamber ventricular pacemakers. Throughout the world, surgeons have been using dual chambered permanent pacemakers with successful follow ups. However, Pakistan has not yet taken the advantage of such pacemaker devices till now. We report three cases that underwent a dual chamber permanent pacemaker implantation for the first time in children less than 8 kg with successful follow ups. (author)

  18. Depth of valve implantation, conduction disturbances and pacemaker implantation with CoreValve and CoreValve Accutrak system for Transcatheter Aortic Valve Implantation, a multi-center study.

    Science.gov (United States)

    Lenders, Guy D; Collas, Valérie; Hernandez, José Maria; Legrand, Victor; Danenberg, Haim D; den Heijer, Peter; Rodrigus, Inez E; Paelinck, Bernard P; Vrints, Christiaan J; Bosmans, Johan M

    2014-10-20

    Transcatheter Aortic Valve Implantation (TAVI) is now considered an indispensable treatment strategy in high operative risk patients with severe, symptomatic aortic stenosis. However, conduction disturbances and the need for Permanent Pacemaker (PPM) implantation after TAVI with the CoreValve prosthesis still remain frequent. We aimed to evaluate the implantation depth, the incidence and predictors of new conduction disturbances, and the need for PPM implantation within the first month after TAVI, using the new Accutrak CoreValve delivery system (ACV), compared to the previous generation CoreValve (non-ACV). In 5 experienced TAVI-centers, a total of 120 consecutive non-ACV and 112 consecutive ACV patients were included (n=232). The mean depth of valve implantation (DVI) was 8.4±4.0 mm in the non-ACV group and 7.1±4.0 mm in the ACV group (p=0.034). The combined incidence of new PPM implantation and new LBBB was 71.2% in the non-ACV group compared to 50.5% in the ACV group (p=0.014). DVI (p=0.002), first degree AV block (p=0.018) and RBBB (p<0.001) were independent predictors of PPM implantation. DVI (p<0.001) and pre-existing first degree AV-block (p=0.021) were identified as significant predictors of new LBBB. DVI is an independent predictor of TAVI-related conduction disturbances and can be reduced by using the newer CoreValve Accutrak delivery system, resulting in a significantly lower incidence of new LBBB and new PPM implantation. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  19. EEG Signal Quality of a Subcutaneous Recording System Compared to Standard Surface Electrodes

    Directory of Open Access Journals (Sweden)

    Jonas Duun-Henriksen

    2015-01-01

    Full Text Available Purpose. We provide a comprehensive verification of a new subcutaneous EEG recording device which promises robust and unobtrusive measurements over ultra-long time periods. The approach is evaluated against a state-of-the-art surface EEG electrode technology. Materials and Methods. An electrode powered by an inductive link was subcutaneously implanted on five subjects. Surface electrodes were placed at sites corresponding to the subcutaneous electrodes, and the EEG signals were evaluated with both quantitative (power spectral density and coherence analysis and qualitative (blinded subjective scoring by neurophysiologists analysis. Results. The power spectral density and coherence analysis were very similar during measurements of resting EEG. The scoring by neurophysiologists showed a higher EEG quality for the implanted system for different subject states (eyes open and eyes closed. This was most likely due to higher amplitude of the subcutaneous signals. During periods with artifacts, such as chewing, blinking, and eye movement, the two systems performed equally well. Conclusions. Subcutaneous measurements of EEG with the test device showed high quality as measured by both quantitative and more subjective qualitative methods. The signal might be superior to surface EEG in some aspects and provides a method of ultra-long term EEG recording in situations where this is required and where a small number of EEG electrodes are sufficient.

  20. Surface treatment of a titanium implant using low temperature atmospheric pressure plasmas

    Science.gov (United States)

    Lee, Hyun-Young; Tang, Tianyu; Ok, Jung-Woo; Kim, Dong-Hyun; Lee, Ho-Jun; Lee, Hae June

    2015-09-01

    During the last two decades, atmospheric pressure plasmas(APP) are widely used in diverse fields of biomedical applications, reduction of pollutants, and surface treatment of materials. Applications of APP to titanium surface of dental implants is steadily increasing as it renders surfaces wettability and modifies the oxide layer of titanium that hinders the interaction with cells and proteins. In this study, we have treated the titanium surfaces of screw-shaped implant samples using a plasma jet which is composed of a ceramic coaxial tube of dielectrics, a stainless steel inner electrode, and a coper tube outer electrode. The plasma ignition occurred with Ar gas flow between two coaxial metal electrodes and a sinusoidal bias voltage of 3 kV with a frequency of 20 kHz. Titanium materials used in this study are screw-shaped implants of which diameter and length are 5 mm and 13 mm, respectively. Samples were mounted at a distance of 5 mm below the plasma source, and the plasma treatment time was set to 3 min. The wettability of titanium surface was measured by the moving speed of water on its surface, which is enhanced by plasma treatment. The surface roughness was also measured by atomic force microscopy. The optimal condition for wettability change is discussed.

  1. Restoration of ankle movements with the ActiGait implantable drop foot stimulator: a safe and reliable treatment option for permanent central leg palsy.

    Science.gov (United States)

    Martin, Klaus Daniel; Polanski, Witold Henryk; Schulz, Anne-Kathrin; Jöbges, Michael; Hoff, Hansjoerg; Schackert, Gabriele; Pinzer, Thomas; Sobottka, Stephan B

    2016-01-01

    OBJECT The ActiGait drop foot stimulator is a promising technique for restoration of lost ankle function by an implantable hybrid stimulation system. It allows ankle dorsiflexion by active peroneal nerve stimulation during the swing phase of gait. In this paper the authors report the outcome of the first prospective study on a large number of patients with stroke-related drop foot. METHODS Twenty-seven patients who experienced a stroke and with persisting spastic leg paresis received an implantable ActiGait drop foot stimulator for restoration of ankle movement after successful surface test stimulation. After 3 to 5 weeks, the stimulator was activated, and gait speed, gait endurance, and activation time of the system were evaluated and compared with preoperative gait tests. In addition, patient satisfaction was assessed using a questionnaire. RESULTS Postoperative gait speed significantly improved from 33.9 seconds per 20 meters to 17.9 seconds per 20 meters (p < 0.0001), gait endurance from 196 meters in 6 minutes to 401 meters in 6 minutes (p < 0.0001), and activation time from 20.5 seconds to 10.6 seconds on average (p < 0.0001). In 2 patients with nerve injury, surgical repositioning of the electrode cuff became necessary. One patient showed a delayed wound healing, and in another patient the system had to be removed because of a wound infection. Marked improvement in mobility, social participation, and quality of life was confirmed by 89% to 96% of patients. CONCLUSIONS The ActiGait implantable drop foot stimulator improves gait speed, endurance, and quality of life in patients with stroke-related drop foot. Regarding gait speed, the ActiGait system appears to be advantageous compared with foot orthosis or surface stimulation devices. Randomized trials with more patients and longer observation periods are needed to prove the long-term benefit of this device.

  2. Some technical nuances for deep brain stimulator implantation

    Directory of Open Access Journals (Sweden)

    Cole A. Giller, MD, PhD, MBA

    2015-03-01

    Full Text Available Protocols for deep brain stimulator (DBS implantation vary significantly among movement disorders centers despite the need to address similar operative problems. The general steps of this procedure are well accepted, but there are many seemingly minor, yet important nuances not extensively discussed in published descriptions. A classification and the details of the nuances adopted by a single institution may therefore be helpful in providing a basis for discussion and comparison. We describe operative nuances adopted at the Georgia Regents Medical Center (GRMC for DBS implantation that may not be universally employed. The problems of DBS implantation considered here include stereotactic planning, draping, creation and use of the burhole, physiological testing, anchoring of the electrode, financial considerations, and overall technique. Fourteen categories of operative nuances were identified and described in detail. These include the use of specific anatomical relationships for planning, the use of clear and watertight drapes, countersinking of the burhole, the use of gelfoam and tissue glue to seal the burhole, methods to review the entire microelectrode data simultaneously, blinded communication with the patient during macrostimulation, fluoroscopic marking, MRI compatible protection of the electrode tip, financial considerations effecting choice of operative materials, and restriction to a single operator. The majority of these have not been extensively described but may be in use at other centers. The many operative problems arising during DBS implantation can be addressed with specific technical nuances.

  3. An implantable integrated low-power amplifier-microelectrode array for Brain-Machine Interfaces.

    Science.gov (United States)

    Patrick, Erin; Sankar, Viswanath; Rowe, William; Sanchez, Justin C; Nishida, Toshikazu

    2010-01-01

    One of the important challenges in designing Brain-Machine Interfaces (BMI) is to build implantable systems that have the ability to reliably process the activity of large ensembles of cortical neurons. In this paper, we report the design, fabrication, and testing of a polyimide-based microelectrode array integrated with a low-power amplifier as part of the Florida Wireless Integrated Recording Electrode (FWIRE) project at the University of Florida developing a fully implantable neural recording system for BMI applications. The electrode array was fabricated using planar micromachining MEMS processes and hybrid packaged with the amplifier die using a flip-chip bonding technique. The system was tested both on bench and in-vivo. Acute and chronic neural recordings were obtained from a rodent for a period of 42 days. The electrode-amplifier performance was analyzed over the chronic recording period with the observation of a noise floor of 4.5 microVrms, and an average signal-to-noise ratio of 3.8.

  4. Bio-inspired hybrid microelectrodes: a hybrid solution to improve long-term performance of chronic intracortical implants.

    Science.gov (United States)

    De Faveri, Sara; Maggiolini, Emma; Miele, Ermanno; De Angelis, Francesco; Cesca, Fabrizia; Benfenati, Fabio; Fadiga, Luciano

    2014-01-01

    The use of implants that allow chronic electrical stimulation and recording in the brain of human patients is currently limited by a series of events that cause the deterioration over time of both the electrode surface and the surrounding tissue. The main reason of failure is the tissue inflammatory reaction that eventually causes neuronal loss and glial encapsulation, resulting in a progressive increase of the electrode-electrolyte impedance. Here, we describe a new method to create bio-inspired electrodes to mimic the mechanical properties and biological composition of the host tissue. This combination has a great potential to increase the implant lifetime by reducing tissue reaction and improving electrical coupling. Our method implies coating the electrode with reprogrammed neural or glial cells encapsulated within a hydrogel layer. We chose fibrin as a hydrogel and primary hippocampal neurons or astrocytes from rat brain as cellular layer. We demonstrate that fibrin coating is highly biocompatible, forms uniform coatings of controllable thickness, does not alter the electrochemical properties of the microelectrode and allows good quality recordings. Moreover, it reduces the amount of host reactive astrocytes - over time - compared to a bare wire and is fully reabsorbed by the surrounding tissue within 7 days after implantation, avoiding the common problem of hydrogels swelling. Both astrocytes and neurons could be successfully grown onto the electrode surface within the fibrin hydrogel without altering the electrochemical properties of the microelectrode. This bio-hybrid device has therefore a good potential to improve the electrical integration at the neuron-electrode interface and support the long-term success of neural prostheses.

  5. Scanning electron microscopy of chronically implanted intracortical microelectrode arrays in non-human primates

    Science.gov (United States)

    Barrese, James C.; Aceros, Juan; Donoghue, John P.

    2016-04-01

    Objective. Signal attenuation is a major problem facing intracortical sensors for chronic neuroprosthetic applications. Many studies suggest that failure is due to gliosis around the electrode tips, however, mechanical and material causes of failure are often overlooked. The purpose of this study was to investigate the factors contributing to progressive signal decline by using scanning electron microscopy (SEM) to visualize structural changes in chronically implanted arrays and histology to examine the tissue response at corresponding implant sites. Approach. We examined eight chronically implanted intracortical microelectrode arrays (MEAs) explanted from non-human primates at times ranging from 37 to 1051 days post-implant. We used SEM, in vivo neural recordings, and histology (GFAP, Iba-1, NeuN). Three MEAs that were never implanted were also imaged as controls. Main results. SEM revealed progressive corrosion of the platinum electrode tips and changes to the underlying silicon. The parylene insulation was prone to cracking and delamination, and in some instances the silicone elastomer also delaminated from the edges of the MEA. Substantial tissue encapsulation was observed and was often seen growing into defects in the platinum and parylene. These material defects became more common as the time in vivo increased. Histology at 37 and 1051 days post-implant showed gliosis, disruption of normal cortical architecture with minimal neuronal loss, and high Iba-1 reactivity, especially within the arachnoid and dura. Electrode tracts were either absent or barely visible in the cortex at 1051 days, but were seen in the fibrotic encapsulation material suggesting that the MEAs were lifted out of the brain. Neural recordings showed a progressive drop in impedance, signal amplitude, and viable channels over time. Significance. These results provide evidence that signal loss in MEAs is truly multifactorial. Gliosis occurs in the first few months after implantation but does

  6. Evaluation of the hybrid-L24 electrode using microcomputed tomography.

    Science.gov (United States)

    Driscoll, Colin L W; Carlson, Matthew L; Fama, Anthony F; Lane, John I

    2011-07-01

    To compare electrode array position, and depth of insertion of the Cochlear Hybrid-L24 electrode array following traditional cochleostomy and round window (RW) insertion. Prospective cadaveric temporal bone study. Ten cadaveric temporal bones were implanted with the Hybrid-L24 electrode array; half were introduced through a RW approach, whereas the other half were inserted through a traditional scala tympani cochleostomy. A micro-CT scanner was then used to evaluate electrode position, intracochlear trauma, and depth of insertion. All electrodes were inserted into the scala tympani without significant resistance. No electrodes demonstrated tip fold-over or through-fracturing of the osseous spiral lamina, basilar membrane, or spiral ligament. The average angular depth of insertion for all 10 electrodes was 252.4°. Compared to cochleostomy insertions, electrodes inserted through the RW more commonly acquired a proximal perimodiolar orientation, followed a more predictable course, and less commonly contacted critical soft tissue structures. The results of this study demonstrate that the Hybrid-L24 electrode can be successfully inserted using a RW or traditional cochleostomy technique with minimal intracochlear trauma. Our data also suggests that with this model, RW insertions may provide particular advantages with respect to hearing preservation over the traditional cochleostomy approach. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.

  7. ORGANIC ELECTRODE COATINGS FOR NEXT-GENERATION NEURAL INTERFACES

    Directory of Open Access Journals (Sweden)

    Ulises A Aregueta-Robles

    2014-05-01

    Full Text Available Traditional neuronal interfaces utilize metallic electrodes which in recent years have reached a plateau in terms of the ability to provide safe stimulation at high resolution or rather with high densities of microelectrodes with improved spatial selectivity. To achieve higher resolution it has become clear that reducing the size of electrodes is required to enable higher electrode counts from the implant device. The limitations of interfacing electrodes including low charge injection limits, mechanical mismatch and foreign body response can be addressed through the use of organic electrode coatings which typically provide a softer, more roughened surface to enable both improved charge transfer and lower mechanical mismatch with neural tissue. Coating electrodes with conductive polymers or carbon nanotubes offers a substantial increase in charge transfer area compared to conventional platinum electrodes. These organic conductors provide safe electrical stimulation of tissue while avoiding undesirable chemical reactions and cell damage. However, the mechanical properties of conductive polymers are not ideal, as they are quite brittle. Hydrogel polymers present a versatile coating option for electrodes as they can be chemically modified to provide a soft and conductive scaffold. However, the in vivo chronic inflammatory response of these conductive hydrogels remains unknown. A more recent approach proposes tissue engineering the electrode interface through the use of encapsulated neurons within hydrogel coatings. This approach may provide a method for activating tissue at the cellular scale, however several technological challenges must be addressed to demonstrate feasibility of this innovative idea. The review focuses on the various organic coatings which have been investigated to improve neural interface electrodes.

  8. Ejaculatory Function After Permanent 125I Prostate Brachytherapy for Localized Prostate Cancer

    International Nuclear Information System (INIS)

    Huyghe, Eric; Delannes, Martine; Wagner, Fabien M.; Delaunay, Boris; Nohra, Joe; Thoulouzan, Matthieu; Shut-Yee, J. Yeung; Plante, Pierre; Soulie, Michel; Thonneau, Patrick; Bachaud, Jean Marc

    2009-01-01

    Purpose: Ejaculatory function is an underreported aspect of male sexuality in men treated for prostate cancer. We conducted the first detailed analysis of ejaculatory function in patients treated with permanent 125 I prostate brachytherapy for localized prostate cancer. Patients and Methods: Of 270 sexually active men with localized prostate cancer treated with permanent 125 I prostate brachytherapy, 241 (89%), with a mean age of 65 years (range, 43-80), responded to a mailed questionnaire derived from the Male Sexual Health Questionnaire regarding ejaculatory function. Five aspects of ejaculatory function were examined: frequency, volume, dry ejaculation, pleasure, and pain. Results: Of the 241 sexually active men, 81.3% had conserved ejaculatory function after prostate brachytherapy; however, the number of patients with rare/absent ejaculatory function was double the pretreatment number (p < .0001). The latter finding was correlated with age (p < .001) and the preimplant International Index of Erectile Function score (p < .001). However, 84.9% of patients with maintained ejaculatory function after implantation reported a reduced volume of ejaculate compared with 26.9% before (p < .001), with dry ejaculation accounting for 18.7% of these cases. After treatment, 30.3% of the patients experienced painful ejaculation compared with 12.9% before (p = .0001), and this was associated with a greater number of implanted needles (p = .021) and the existence of painful ejaculation before implantation (p < .0001). After implantation, 10% of patients who continued to be sexually active experienced no orgasm compared with only 1% before treatment. in addition, more patients experienced late/difficult or weak orgasms (p = .001). Conclusion: Most men treated with brachytherapy have conserved ejaculatory function after prostate brachytherapy. However, most of these men experience a reduction in volume and a deterioration in orgasm.

  9. Transcanal labyrinthectomy for intractable vertigo after unilateral cochlear implantation.

    Science.gov (United States)

    Heidenreich, Katherine D; Basura, Gregory J; Zwolan, Teresa A; El-Kashlan, Hussam K; Telian, Steven A

    2011-10-01

    Document the use of transcanal labyrinthectomy to treat disabling attacks of vertigo after unilateral cochlear implantation. A 46-year-old woman with severe-profound bilateral sensorineural hearing loss secondary to enlarged vestibular aqueducts underwent cochlear implantation for her right ear with a Nucleus Freedom device. The surgery was uneventful, and postoperative imaging confirmed that the electrode was positioned properly. She developed episodic vertigo 10 to 14 days after the implant surgery, which failed to improve with aggressive vestibular rehabilitation therapy. Plugging of the round window for possible perilymphatic fistula did not relieve her symptoms. Right transcanal labyrinthectomy supplemented by filling the vestibule with gentamicin-soaked Gelfoam and then a customized vestibular rehabilitation program. Comparison of vestibular symptoms and cochlear implant performance before and after transcanal labyrinthectomy. The patient had immediate relief of symptoms, and the function of the cochlear implant was not adversely affected. Transcanal labyrinthectomy may be an effective method to ablate the vestibular end organ after unilateral cochlear implantation. It can offer relief of disabling vertigo without adversely affecting the performance of the implant.

  10. Binaural release from masking with single- and multi-electrode stimulation in children with cochlear implantsa)

    Science.gov (United States)

    Todd, Ann E.; Goupell, Matthew J.; Litovsky, Ruth Y.

    2016-01-01

    Cochlear implants (CIs) provide children with access to speech information from a young age. Despite bilateral cochlear implantation becoming common, use of spatial cues in free field is smaller than in normal-hearing children. Clinically fit CIs are not synchronized across the ears; thus binaural experiments must utilize research processors that can control binaural cues with precision. Research to date has used single pairs of electrodes, which is insufficient for representing speech. Little is known about how children with bilateral CIs process binaural information with multi-electrode stimulation. Toward the goal of improving binaural unmasking of speech, this study evaluated binaural unmasking with multi- and single-electrode stimulation. Results showed that performance with multi-electrode stimulation was similar to the best performance with single-electrode stimulation. This was similar to the pattern of performance shown by normal-hearing adults when presented an acoustic CI simulation. Diotic and dichotic signal detection thresholds of the children with CIs were similar to those of normal-hearing children listening to a CI simulation. The magnitude of binaural unmasking was not related to whether the children with CIs had good interaural time difference sensitivity. Results support the potential for benefits from binaural hearing and speech unmasking in children with bilateral CIs. PMID:27475132

  11. Current state of knowledge and experts' perspective on the subcutaneous implantable cardioverter-defibrillator.

    Science.gov (United States)

    Santini, Massimo; Cappato, Riccardo; Andresen, Dietrich; Brachmann, Johannes; Davies, D Wyn; Cleland, John; Filippi, Alessandro; Gronda, Edoardo; Hauer, Richard; Steinbeck, Gerhard; Steinhaus, David

    2009-06-01

    ICD implantation is today a well-recognized therapy to prevent sudden cardiac death. The available implantable devices at present need the use of permanent endocavitary leads which may cause, in some instances, serious troubles to the patients (lead dislodgement, ventricular perforation, lead infections, etc.). A new implantable defibrillator provided by only a subcutaneous lead is at present under evaluation. Its potential indications, usefulness benefits, and problems represent an interesting field of investigation and discussion. This paper describes the conclusions recently reached by a panel of experts, with regard to the potential role of an implantable subcutaneous defibrillator in the prevention of sudden cardiac death.

  12. Slim 198gold-grain implanter loaded with standard royal marsden 14-grain magazines

    International Nuclear Information System (INIS)

    Delclos, L.; Moore, E.B.

    1979-01-01

    We designed a slim gold-grain implanter with adaptable lengths to implant areas accessible only through long, narrow, examining instruments, such as a suspension laryngoscope. The implanter is loaded with the same 14-grain magazine designed for and supplied with the Royal Marsden gun. The simplicity of the loading mechanism with a minimum of moving parts makes the instrument practically trouble free. Although it is designed to be used along narrow examining instruments, it can also be used in any situation in which a permanent implant is required, for instance, prostatic cancer and pelvic recurrences in cancer of the uterine cervix previously treated by external and intracavitary irradiation

  13. ANTIARRHYTMIC EFFICACY OF SOTALOL IN PATIENTS WITH TACHY-BRADY SYNDROME HAVING ATRIAL PACEMAKER WITH DIFFERENT ATRIAL ELECTRODE POSITION

    Directory of Open Access Journals (Sweden)

    T. N. Novikova

    2009-01-01

    Full Text Available Aim. To evaluate efficacy of the combined therapy (sotalol and constant electric cardiostimulation in AAI regimen at two atrial electrode position: in low back part of interatrial septum (IAS and in right atrial auricle (RAA.Material and methods. 20 patients with tachy-brady syndrome were examined. They were randomized in 2 groups depending on atrial electrode position. Sotalol (160 mg daily was prescribed to all patients in a month after implantation of constant atrial pacemaker (CAP. A number of atrial fibrillation paroxysms (AFP was evaluated initially, in a month after CAP implantation and in a month after start of sotalol therapy.Results. Significant AFP reduction was observed in IAS stimulation, unlike RAA stimulation. Sotalol addition had essential significance in the termination or reduction of AFP. Sotalol effect did not depend on atrial electrode position.Conclusion. Sotalol usage together with constant electric cardiostimulation significantly reduces AFP irrespectively of atrial electrode position. 

  14. Evaluation of focused multipolar stimulation for cochlear implants: a preclinical safety study

    Science.gov (United States)

    Shepherd, Robert K.; Wise, Andrew K.; Enke, Ya Lang; Carter, Paul M.; Fallon, James B.

    2017-08-01

    Objective. Cochlear implants (CIs) have a limited number of independent stimulation channels due to the highly conductive nature of the fluid-filled cochlea. Attempts to develop highly focused stimulation to improve speech perception in CI users includes the use of simultaneous stimulation via multiple current sources. Focused multipolar (FMP) stimulation is an example of this approach and has been shown to reduce interaction between stimulating channels. However, compared with conventional biphasic current pulses generated from a single current source, FMP is a complex stimulus that includes extended periods of stimulation before charge recovery is achieved, raising questions on whether chronic stimulation with this strategy is safe. The present study evaluated the long-term safety of intracochlear stimulation using FMP in a preclinical animal model of profound deafness. Approach. Six cats were bilaterally implanted with scala tympani electrode arrays two months after deafening, and received continuous unilateral FMP stimulation at levels that evoked a behavioural response for periods of up to 182 d. Electrode impedance, electrically-evoked compound action potentials (ECAPs) and auditory brainstem responses (EABRs) were monitored periodically over the course of the stimulation program from both the stimulated and contralateral control cochleae. On completion of the stimulation program cochleae were examined histologically and the electrode arrays were evaluated for evidence of platinum (Pt) corrosion. Main results. There was no significant difference in electrode impedance between control and chronically stimulated electrodes following long-term FMP stimulation. Moreover, there was no significant difference between ECAP and EABR thresholds evoked from control or stimulated cochleae at either the onset of stimulation or at completion of the stimulation program. Chronic FMP stimulation had no effect on spiral ganglion neuron (SGN) survival when compared with

  15. The consequences of neural degeneration regarding optimal cochlear implant position in scala tympani: a model approach.

    Science.gov (United States)

    Briaire, Jeroen J; Frijns, Johan H M

    2006-04-01

    Cochlear implant research endeavors to optimize the spatial selectivity, threshold and dynamic range with the objective of improving the speech perception performance of the implant user. One of the ways to achieve some of these goals is by electrode design. New cochlear implant electrode designs strive to bring the electrode contacts into close proximity to the nerve fibers in the modiolus: this is done by placing the contacts on the medial side of the array and positioning the implant against the medial wall of scala tympani. The question remains whether this is the optimal position for a cochlea with intact neural fibers and, if so, whether it is also true for a cochlea with degenerated neural fibers. In this study a computational model of the implanted human cochlea is used to investigate the optimal position of the array with respect to threshold, dynamic range and spatial selectivity for a cochlea with intact nerve fibers and for degenerated nerve fibers. In addition, the model is used to evaluate the predictive value of eCAP measurements for obtaining peri-operative information on the neural status. The model predicts improved threshold, dynamic range and spatial selectivity for the peri-modiolar position at the basal end of the cochlea, with minimal influence of neural degeneration. At the apical end of the array (1.5 cochlear turns), the dynamic range and the spatial selectivity are limited due to the occurrence of cross-turn stimulation, with the exception of the condition without neural degeneration and with the electrode array along the lateral wall of scala tympani. The eCAP simulations indicate that a large P(0) peak occurs before the N(1)P(1) complex when the fibers are not degenerated. The absence of this peak might be used as an indicator for neural degeneration.

  16. Study on hydrogen assisted cracking susceptibility of HSLA steel by implant test

    Directory of Open Access Journals (Sweden)

    Gopa Chakraborty

    2016-12-01

    Full Text Available DMR-249A is an indigenously developed high strength low alloy steel for Indian ship building industry for making ship-hull and is extensively used in the construction of war ships and submarines. Welding electrodes conforming to SFA 5.5 AWS E8018 C1 has been indigenously developed for welding of this steel using shielded metal arc welding process. In the present study, susceptibility to hydrogen assisted cracking of DMR-249A steel welds made using this electrode has been assessed using implant test. Implant tests were conducted using this electrode at two different levels of diffusible hydrogen, measured using gas chromatography technique. It is observed that both the steel and the welding consumable are not susceptible to hydrogen assisted cracking even with a high diffusible hydrogen level of 9 mL/100g of weld metal. In implant tests, specimen did not fracture even after loading to stress levels higher than the yield strength of the base metal. The good resistance of this steel and the welding consumable, even with high levels of diffusible hydrogen, is attributed to absence of a susceptible microstructure in both the weld metal and heat affected zone. Hence, this study shows that, in the absence of a susceptible microstructure, hydrogen assisted cracking is unlikely to occur even if hydrogen level is high. It also confirms that in welding of DMR-249A with indigenously developed E8018 C1 electrode, hydrogen assisted cracking is not a concern and no preheating is required to avoid it during welding.

  17. Cochlear implantation in X-linked deafness - How to manage the surgical challenges.

    Science.gov (United States)

    Saeed, Haroon; Powell, Harry R F; Saeed, Shakeel R

    2016-07-01

    In children with X-linked deafness, cochlear malformations challenge the implant surgeon to avoid electrode insertion into the internal auditory meatus and prevent a continuous cerebrospinal fluid (CSF) leak. We describe our experience of cochlear implantation (CI) in two children with profound hearing loss secondary to X-linked deafness, highlighting safer operative techniques to avoid potential complications. Descriptive cases of two children with X-linked deafness (patient 1 and patient 2) undergoing CI. Peri-operative imaging and work-up to surgery are discussed. Specific operative considerations, post-operative complications and subsequent audiological performance are highlighted. In each case, intra-operative fluoroscopic imaging ensured intra-cochlear insertion of electrodes. Expected CSF gusher was seen in each case which was initially controlled by packing around the cochleostomy and array with temporalis muscle and fascia. Patient 1 developed post-operative meningitis secondary to continuous CSF leak. We avoided further significant CSF leak by planning staged procedures for patient 2, with obliteration of the middle ear cleft and external ear canal (EAC) at the time of implantation. In both patients, bilateral implantation successfully provided hearing thresholds of less than 35 dB in both ears at routine follow up. When planning for CI in children with radiological features of X-linked deafness, intra-operative imaging should be utilized to ensure correct electrode positioning. Traditional methods of stopping a CSF gusher may not suffice. We therefore encourage additional surgical obliteration of the middle ear space and EAC to avoid persistent CSF leak and its associated complications.

  18. Cochlear implantation: is hearing preservation necessary in severe to profound hearing loss?

    Science.gov (United States)

    Derinsu, Ufuk; Serin, Gediz Murat; Akdaş, Ferda; Batman, Çağlar

    2011-03-01

    The goal of the cochlear implant surgery is to place the electrode array with minimal damage to preserve the residual hearing. Round-window insertion can be performed in a manner that is potentially less traumatic than the standard cochleostomy. The purpose of the study was to investigate audiological results of the round-window approach using standard electrode. A retrospective study was performed to evaluate our experience in patients with implanted through round window between January 2007 and March 2009. Sixty patients had undergone cochlear implant surgery through the round window with full insertion of a standard electrode array. Preoperative and postoperative pure-tone thresholds were measured for implanted ears in the range of 250 to 4000 Hz. Within these 60 cases, 31 patients had been evaluated. The population comprised 16 women and 15 men. The mean age was 15.96 years (range, 4-64 years). Follow-up times ranged from 6 to 26 months. Preservation of low-frequency hearing (250 and 500 Hz) was achieved in 27 (87%) of 31 patients. Complete hearing preservation (all frequencies) was accomplished in 11 patients (35.48%). No hearing could be determined postoperatively in 4 patients (12.9%), having preoperative thresholds of 120 dB at 250, 500, and 1000 Hz. Round-window approach has been widely used for preservation of residual hearing. In our patients with severe to profound hearing loss, we preserved residual hearing. Although the residual hearing cannot be sufficient for using additional acoustic stimulation, the preserved residual hearing means minimal damage and a more convenient cochlea, so this is promising for future development.

  19. Cochlear implant revision surgeries in children.

    Science.gov (United States)

    Amaral, Maria Stella Arantes do; Reis, Ana Cláudia Mirândola B; Massuda, Eduardo T; Hyppolito, Miguel Angelo

    2018-02-16

    The surgery during which the cochlear implant internal device is implanted is not entirely free of risks and may produce problems that will require revision surgeries. To verify the indications for cochlear implantation revision surgery for the cochlear implant internal device, its effectiveness and its correlation with certain variables related to language and hearing. A retrospective study of patients under 18 years submitted to cochlear implant Surgery from 2004 to 2015 in a public hospital in Brazil. Data collected were: age at the time of implantation, gender, etiology of the hearing loss, audiological and oral language characteristics of each patient before and after Cochlear Implant surgery and any need for surgical revision and the reason for it. Two hundred and sixty-five surgeries were performed in 236 patients. Eight patients received a bilateral cochlear implant and 10 patients required revision surgery. Thirty-two surgeries were necessary for these 10 children (1 bilateral cochlear implant), of which 21 were revision surgeries. In 2 children, cochlear implant removal was necessary, without reimplantation, one with cochlear malformation due to incomplete partition type I and another due to trauma. With respect to the cause for revision surgery, of the 8 children who were successfully reimplanted, four had cochlear calcification following meningitis, one followed trauma, one exhibited a facial nerve malformation, one experienced a failure of the cochlear implant internal device and one revision surgery was necessary because the electrode was twisted. The incidence of the cochlear implant revision surgery was 4.23%. The period following the revision surgeries revealed an improvement in the subject's hearing and language performance, indicating that these surgeries are valid in most cases. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  20. The double capsules in macro-textured breast implants.

    Science.gov (United States)

    Giot, Jean-Philippe; Paek, Laurence S; Nizard, Nathanael; El-Diwany, Mostafa; Gaboury, Louis A; Nelea, Monica; Bou-Merhi, Joseph S; Harris, Patrick G; Danino, Michel A

    2015-10-01

    Breast implants are amongst the most widely used types of permanent implants in modern medicine and have both aesthetic and reconstructive applications with excellent biocompatibility. The double capsule is a complication associated with textured prostheses that leads to implant displacement; however, its etiology has yet to be elucidated. In this study, 10 double capsules were sampled from breast expander implants for in-depth analysis; histologically, the inner capsular layer demonstrated highly organized collagen in sheets with delamination of fibers. At the prosthesis interface (PI) where the implant shell contacts the inner capsular layer, scanning electron microscopy (SEM) revealed a thin layer which mirrored the three-dimensional characteristics of the implant texture; the external surface of the inner capsular layer facing the intercapsular space (ICS) was flat. SEM examination of the inner capsule layer revealed both a large bacterial presence as well as biofilm deposition at the PI; a significantly lower quantity of bacteria and biofilm were found at the ICS interface. These findings suggest that the double capsule phenomenon's etiopathogenesis is of mechanical origin. Delamination of the periprosthetic capsule leads to the creation of the ICS; the maintained separation of the 2 layers subsequently alters the biostability of the macro-textured breast implant. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Efficacy of postoperative prophylactic antibiotics in reducing permanent pacemaker infections.

    Science.gov (United States)

    Lee, Wen-Huang; Huang, Ting-Chun; Lin, Li-Jen; Lee, Po-Tseng; Lin, Chih-Chan; Lee, Cheng-Han; Chao, Ting-Hsing; Li, Yi-Heng; Chen, Ju-Yi

    2017-08-01

    Despite limited evidence, postoperative prophylactic antibiotics are often used in the setting of permanent pacemaker implantation or replacement. The aim of this study is to investigate the efficacy of postoperative antibiotics. Postoperative prophylactic antibiotics may be not clinically useful. We recruited 367 consecutive patients undergoing permanent pacemaker implantation or generator replacement at a tertiary referral center. Baseline demographics, clinical characteristics, and procedure information were collected, and all patients received preoperative prophylactic antibiotics. Postoperative prophylactic antibiotics were administered at the discretion of the treating physician, and all patients were seen in follow-up every 3 to 6 months for an average follow-up period of 16 months. The primary endpoint was device-related infection. A total of 110 patients were treated with preoperative antibiotics only (group 1), whereas 257 patients received both preoperative and postoperative antibiotics (group 2). After a mean follow-up period of 16 months, 1 patient in group 1 (0.9%) and 4 patients in group 2 (1.5%) experienced a device-related infection. There was no significant difference in the rate of infection between the 2 groups (P = 0.624). In the univariate analysis, only the age (60 ± 11 vs 75 ± 12 years, P antibiotics had a similar rate of infection as those treated with preoperative antibiotics alone. Further studies are needed to confirm these preliminary findings. © 2017 Wiley Periodicals, Inc.

  2. Controllably annealed CuO-nanoparticle modified ITO electrodes: Characterisation and electrochemical studies

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Tong; Su, Wen; Fu, Yingyi [College of Chemistry, Beijing Normal University, Beijing 100875 (China); Hu, Jingbo, E-mail: hujingbo@bnu.edu.cn [College of Chemistry, Beijing Normal University, Beijing 100875 (China); Key Laboratory of Beam Technology and Material Modification of Ministry of Education, Beijing Normal University, Beijing 100875 (China)

    2016-12-30

    Graphical abstract: We report a simple and controllable synthesis of CuO-nanoparticle-modified ITO by employing a combination of ion-implantation and annealing methods for the first time. The optimum CuO/ITO electrode shows uniform morphology, highly accessible surface area, long-term stability and excellent electrochemical performance towards biomolecules such as glucose in alkaline solution. - Highlights: • Controllably annealed CuO/ITO electrode was synthesized for the first time. • The generation mechanism of CuO nanoparticles is revealed. • The optimum CuO/ITO electrode shows excellent electrochemical performance. • A reference for the controllable preparation of other metal oxide nanoparticles. - Abstract: In this paper, we report a facile and controllable two-step approach to produce indium tin oxide electrodes modified by copper(II) oxide nanoparticles (CuO/ITO) through ion implantation and annealing methods. After annealing treatment, the surface morphology of the CuO/ITO substrate changed remarkably and exhibited highly electroactive sites and a high specific surface area. The effects of annealing treatment on the synthesis of CuO/ITO were discussed based on various instruments’ characterisations, and the possible mechanism by which CuO nanoparticles were generated was also proposed in this work. Cyclic voltammetric results indicated that CuO/ITO electrodes exhibited effective catalytic responses toward glucose in alkaline solution. Under optimal experimental conditions, the proposed CuO/ITO electrode showed sensitivity of 450.2 μA cm{sup −2} mM{sup −1} with a linear range of up to ∼4.4 mM and a detection limit of 0.7 μM (S/N = 3). Moreover, CuO/ITO exhibited good poison resistance, reproducibility, and stability properties.

  3. Evaluation of electrode position in deep brain stimulation by image fusion (MRI and CT)

    Energy Technology Data Exchange (ETDEWEB)

    Barnaure, I.; Lovblad, K.O.; Vargas, M.I. [Geneva University Hospital, Department of Neuroradiology, Geneva 14 (Switzerland); Pollak, P.; Horvath, J.; Boex, C.; Burkhard, P. [Geneva University Hospital, Department of Neurology, Geneva (Switzerland); Momjian, S. [Geneva University Hospital, Department of Neurosurgery, Geneva (Switzerland); Remuinan, J. [Geneva University Hospital, Department of Radiology, Geneva (Switzerland)

    2015-09-15

    Imaging has an essential role in the evaluation of correct positioning of electrodes implanted for deep brain stimulation (DBS). Although MRI offers superior anatomic visualization of target sites, there are safety concerns in patients with implanted material; imaging guidelines are inconsistent and vary. The fusion of postoperative CT with preoperative MRI images can be an alternative for the assessment of electrode positioning. The purpose of this study was to assess the accuracy of measurements realized on fused images (acquired without a stereotactic frame) using a manufacturer-provided software. Data from 23 Parkinson's disease patients who underwent bilateral electrode placement for subthalamic nucleus (STN) DBS were acquired. Preoperative high-resolution T2-weighted sequences at 3 T, and postoperative CT series were fused using a commercially available software. Electrode tip position was measured on the obtained images in three directions (in relation to the midline, the AC-PC line and an AC-PC line orthogonal, respectively) and assessed in relation to measures realized on postoperative 3D T1 images acquired at 1.5 T. Mean differences between measures carried out on fused images and on postoperative MRI lay between 0.17 and 0.97 mm. Fusion of CT and MRI images provides a safe and fast technique for postoperative assessment of electrode position in DBS. (orig.)

  4. Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?

    Science.gov (United States)

    Heublein, B; Rohde, R; Kaese, V; Niemeyer, M; Hartung, W; Haverich, A

    2003-06-01

    To develop and test a new concept of the degradation kinetics of newly developed coronary stents consisting of magnesium alloys. Design of a coronary stent prototype consisting of the non-commercial magnesium based alloy AE21 (containing 2% aluminium and 1% rare earths) with an expected 50% loss of mass within six months. Eleven domestic pigs underwent coronary implantation of 20 stents (overstretch injury). No stent caused major problems during implantation or showed signs of initial breakage in the histological evaluation. There were no thromboembolic events. Quantitative angiography at follow up showed a significant (p biocorrosion seem to be a realistic alternative to permanent implants.

  5. Foramen ovale electrodes in the evaluation of epilepsy surgery: conventional and unconventional uses.

    Science.gov (United States)

    Karakis, Ioannis; Velez-Ruiz, Naymee; Pathmanathan, Jay S; Sheth, Sameer A; Eskandar, Emad N; Cole, Andrew J

    2011-10-01

    Foramen ovale (FO) electrodes have been used in the evaluation of epilepsy surgery for more than 25 years. Their traditional application was in patients with mesial temporal lobe epilepsy. Due in part to advances in neuroimaging, their use has declined. We describe our cumulative experience with FO electrodes and use examples to illustrate a range of indications for FO recordings that extend beyond their conventional utility for mesial temporal lobe cases. We also summarize the pros and cons of FO electrodes implantation and attempt to reestablish their utility in presurgical evaluation. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. Quantum effects in ion implanted devices

    International Nuclear Information System (INIS)

    Jamieson, D.N.; Chan, V.; Hudson, F.E.; Andresen, S.E.; Yang, C.; Hopf, T.; Hearne, S.M.; Pakes, C.I.; Prawer, S.; Gauja, E.; Dzurak, A.S.; Clark, R.G.

    2006-01-01

    Fabrication of nanoscale devices that exploit the rules of quantum mechanics to process information presents formidable technical challenges because of the need to control quantum states at the level of individual atoms, electrons or photons. We have used ion implantation to fabricate devices on the scale of 10 nm that have allowed the development and test of nanocircuitry for the control of charge transport at the level of single electrons. This fabrication method is compatible with the construction of devices that employ counted P dopants in Si by employing the technique of ion beam induced charge (IBIC) in which single 14 keV P ions can be implanted into ultra-pure silicon substrates by monitoring on-substrate detector electrodes. We have used IBIC with a MeV nuclear microprobe to map and measure the charge collection efficiency in the development of the electrode structure and show that 100% charge collection efficiency can be achieved. Prototype devices fabricated by this method have been used to investigate quantum effects in the control and transport of single electrons with potential applications to solid state quantum information processing devices

  7. Computer-assisted intraoperative visualization of dental implants. Augmented reality in medicine

    International Nuclear Information System (INIS)

    Ploder, O.; Wagner, A.; Enislidis, G.; Ewers, R.

    1995-01-01

    In this paper, a recently developed computer-based dental implant positioning system with an image-to-tissue interface is presented. On a computer monitor or in a head-up display, planned implant positions and the implant drill are graphically superimposed on the patient's anatomy. Electromagnetic 3D sensors track all skull and jaw movements; their signal feedback to the workstation induces permanent real-time updating of the virtual graphics' position. An experimental study and a clinical case demonstrates the concept of the augmented reality environment - the physician can see the operating field and superimposed virtual structures, such as dental implants and surgical instruments, without loosing visual control of the operating field. Therefore, the operation system allows visualization of CT planned implantposition and the implementation of important anatomical structures. The presented method for the first time links preoperatively acquired radiologic data, planned implant location and intraoperative navigation assistance for orthotopic positioning of dental implants. (orig.) [de

  8. Characterization of ion implanted silicon by the electrolytic reverse current

    International Nuclear Information System (INIS)

    Hueller, J.; Pham, M.T.

    1977-01-01

    The current voltage behaviour of ion implanted silicon electrodes in HF electrolyte is investigated. The electrolytic reverse current, i.e. the reaction rate of the minority carrier limited reactions is found to increase. The current increase depends on the implanted dose and layer stripping. Reason for the increased reverse current can be referred to radiation damage acting as generation centres for minority carriers. Measurement of the electrolytic reverse current can be used for determining damage profiles. Layer stripping is carried out by anodic dissolution in the same electrolyte. The sensitivity of this new method for characterizing ion implanted silicon layers lies at 10 11 to 10 12 atoms/cm 2 . (author)

  9. COCHLEAR IMPLANTATION PREVALENCE IN ELDERLY

    Directory of Open Access Journals (Sweden)

    A. V. Starokha

    2014-01-01

    Full Text Available Current paper describes an experience of cochlear implantation in elderly. Cochlear implantation has become a widely accepted intervention in the treatment of individuals with severe-to-profound sensorineural hearing loss. Cochlear implants are now accepted as a standard of care to optimize hearing and subsequent speech development in children and adults with deafness. But cochlear implantation affects not only hearing abilities, speech perception and speech production; it also has an outstanding impact on the social life, activities and self-esteem of each patient. The aim of this study was to evaluate the cochlear implantation efficacy in elderly with severe to profound sensorineural hearing loss. There were 5 patients under our observation. Surgery was performed according to traditional posterior tympanotomy and cochleostomy for cochlear implant electrode insertion for all observed patients. The study was conducted in two stages: before speech processor’s activation and 3 months later. Pure tone free field audiometry was performed to each patient to assess the efficiency of cochlear implantation in dynamics. The aim of the study was also to evaluate quality of life in elderly with severe to profound sensorineural hearing loss after unilateral cochlear implantation. Each patient underwent questioning with 36 Item Short Form Health Survey (SF-36. SF-36 is a set of generic, coherent, and easily administered quality-of-life measures. The SF-36 consists of eight scaled scores, which are the weighted sums of the questions in their section. Each scale is directly transformed into a 0-100 scale on the assumption that each question carries equal weight. The eight sections are: physical functioning; physical role functioning; emotional role functioning; vitality; emotional well-being; social role functioning; bodily pain; general health perceptions. Our results demonstrate that cochlear implantation in elderly consistently improved quality of life

  10. [Positions of the implanted stimulating electrodes for artificial facial nerve for inducing contraction of the orbicularis oris muscle in rabbit with peripheral facial paralysis].

    Science.gov (United States)

    Xu, D Y; Zhao, N J; Zhao, Y X; Luo, D; Sun, Y J; Li, K Y

    2017-11-07

    Objective: To explore the optimal positions of the implanted stimulating eletrodes for artificial facial nerve (AFN) for inducing contraction of the orbicularis oris muscle (OOM) in rabbit with peripheral facial paralysis. Methods: According to the four microelectrodes of the AFN stimulating side, four modes of the implanted positions were divided. In line with different modes, the electrodes were implanted into the affected OOM of the rabbits with unilateral peripheral facial paralysis. AFN output electric stimulation to induce contraction of the affected OOM with uniform stimulating frequency and pulse length in vitro. Then compared the stimulus threshold amplitude and the peak amplitude separately among different modes by SAS 9.3 version statistical software. Results: The differences of the stimulus threshold amplitude and the peak amplitude had no statistically significant separately between the first mode and the second mode ( P >0.05), but there were statistically significant differences between the third mode and the fourth mode ( P <0.05). Both kinds of the amplitudes were approximated between the first mode and the second mode respectively, and higher than those in the third mode or the fourth mode. Furthermore, both kinds of the amplitudes in the fourth mode were higher than those in the third mode. Conclusions: The microelectrodes of the AFN stimulating lateral are implanted into the upper lip with a public microelectrode and an output microelectrode, into the lower lip with an output microelectrode, and into the way, which is located to the angle 40° to 45° about the line joining between the midpoint of the ipsilateral auricle root and the corner of the mouth with an output microelectrode. This is the third positional mode which requires lowest effective stimulus current intensity. Thus the mode is suitable as the optimal placement programme.

  11. Side effects of permanent I125 prostate seed implants in 667 patients treated in Leeds

    International Nuclear Information System (INIS)

    Bottomley, David; Ash, Dan; Al-Qaisieh, Bashar; Carey, Brendan; Joseph, Joji; St Clair, Shaun; Gould, Kathy

    2007-01-01

    Purpose: To report the side effects and complications after I-125 seeds prostate implant after 8.5 years experience. Methods and materials: Six hundred and sixty seven (667) patients were treated between March 1995 and December 2001. The median follow up is 31 months with a maximum of 98.2 months. Morbidity data were collected from a review of patient case-notes. Patients also provided prospective data on urinary symptoms using the International Prostate Symptom Score (IPSS) scoring chart before treatment and at regular follow up. Patients were also sent a questionnaire detailing symptoms and side effects following their brachytherapy. This enabled them to record urinary, bowel and sexual function side effects independently. Logistic regression analysis was carried out to identify the risk of catheterisation in relation to the pre-implant prostate volume and potential implant factors such as the number of seeds and needles and implant dose. Result: The urinary symptom score rises in the first few months after implantation and returns to within one or two points of the pre-treatment score within one year. Nine patients reported incontinence prior to treatment and 15, 12 and 10 patients reported incontinence 6, 12 and 24 months after treatment, respectively. Catheterisation was reported in 97 (14.5%) patients. At six months 84.9% of patients reported no change in bowel function and 78.9% at 12 months. 6.4% of patients complained of some increased bowel frequency at 6 months and 5.7% at 12 months. 402 (77.2%) patients reported being fully potent before treatment and that this fell to 32.4% after treatment. Logistic regression showed that the most significant factors which correlate with the probability of catheterisation are the pre-treatment prostate volume and the number of seeds and needles implanted. Conclusion: The side effects and complications after prostate brachytherapy as reported here and elsewhere confirm that the treatment is not only convenient but also

  12. Bio-inspired hybrid microelectrodes. A hybrid solution to improve long-term performance of chronic intracortical implants.

    Directory of Open Access Journals (Sweden)

    Sara eDe Faveri

    2014-04-01

    Full Text Available The use of implants that allow chronic electrical stimulation and recording in the brain of human patients is currently limited by a series of events that cause the deterioration over time of both the electrode surface and the surrounding tissue. The main reason of failure is the tissue inflammatory reaction that eventually causes neuronal loss and glial encapsulation, resulting in a progressive increase of the electrode-electrolyte impedance. Here, we describe a new method to create bio-inspired electrodes to mimic the mechanical properties and biological composition of the host tissue. This combination has a great potential to increase the implant lifetime by reducing tissue reaction and improving electrical coupling. Our method implies coating the electrode with reprogrammed neural or glial cells encapsulated within a hydrogel layer. We chose fibrin as a hydrogel and primary hippocampal neurons or astrocytes from rat brain as cellular layer. We demonstrate that fibrin coating is highly biocompatible, forms uniform coatings of controllable thickness, does not alter the electrochemical properties of the microelectrode and allows good quality recordings. Moreover, it reduces the amount of host reactive astrocytes - over time - compared to a bare wire and is fully reabsorbed by the surrounding tissue within 7 days after implantation, avoiding the common problem of hydrogels swelling. Both astrocytes and neurons could be successfully grown onto the electrode surface within the fibrin hydrogel without altering the electrochemical properties of the microelectrode. This bio-hybrid device has therefore a good potential to improve the electrical integration at the neuron-electrode interface and support the long-term success of neural prostheses.

  13. Insertion torque recordings for the diagnosis of contact between orthodontic mini implants and dental roots: protocol for a systematic review

    NARCIS (Netherlands)

    Meursinge Reynders, R.; Ladu, L.; Ronchi, L.; Di Girolama, N.; de Lange, J.; Roberts, N.; Plüddemann, A.

    2015-01-01

    Background Hitting a dental root during the insertion of orthodontic mini-implants (OMIs) is a common adverse effect of this intervention. This condition can permanently damage these structures and can cause implant instability. Increased torque levels (index test) recorded during the insertion of

  14. [Cochlear implantation in patients with Waardenburg syndrome type II].

    Science.gov (United States)

    Wan, Liangcai; Guo, Menghe; Chen, Shuaijun; Liu, Shuangriu; Chen, Hao; Gong, Jian

    2010-05-01

    To describe the multi-channel cochlear implantation in patients with Waardenburg syndrome including surgeries, pre and postoperative hearing assessments as well as outcomes of speech recognition. Multi-channel cochlear implantation surgeries have been performed in 12 cases with Waardenburg syndrome type II in our department from 2000 to 2008. All the patients received multi-channel cochlear implantation through transmastoid facial recess approach. The postoperative outcomes of 12 cases were compared with 12 cases with no inner ear malformation as a control group. The electrodes were totally inserted into the cochlear successfully, there was no facial paralysis and cerebrospinal fluid leakage occurred after operation. The hearing threshold in this series were similar to that of the normal cochlear implantation. After more than half a year of speech rehabilitation, the abilities of speech discrimination and spoken language of all the patients were improved compared with that of preoperation. Multi-channel cochlear implantation could be performed in the cases with Waardenburg syndrome, preoperative hearing and images assessments should be done.

  15. Intensity coding in electric hearing: effects of electrode configurations and stimulation waveforms.

    Science.gov (United States)

    Chua, Tiffany Elise H; Bachman, Mark; Zeng, Fan-Gang

    2011-01-01

    Current cochlear implants typically stimulate the auditory nerve with biphasic pulses and monopolar electrode configurations. Tripolar stimulation can increase spatial selectivity and potentially improve place pitch related perception but requires higher current levels to elicit the same loudness as monopolar stimulation. The present study combined delayed pseudomonophonasic pulses, which produce lower thresholds, with tripolar stimulation in an attempt to solve the power-performance tradeoff problem. The present study systematically measured thresholds, dynamic range, loudness growth, and intensity discrimination using either biphasic or delayed pseudomonophonasic pulses under both monopolar and tripolar stimulation. Participants were five Clarion cochlear implant users. For each subject, data from apical, middle, and basal electrode positions were collected when possible. Compared with biphasic pulses, delayed pseudomonophonasic pulses increased the dynamic range by lowering thresholds while maintaining comparable maximum allowable levels under both electrode configurations. However, delayed pseudomonophonasic pulses did not change the shape of loudness growth function and actually increased intensity discrimination limens, especially at lower current levels. The present results indicate that delayed pseudomonophonasic pulses coupled with tripolar stimulation cannot provide significant power savings nor can it increase the functional dynamic range. Whether this combined stimulation could improve functional spectral resolution remains to be seen.

  16. Spinal Anesthesia and Minimal Invasive Laminotomy for Paddle Electrode Placement in Spinal Cord Stimulation: Technical Report and Clinical Results at Long-Term Followup

    Directory of Open Access Journals (Sweden)

    S. Sarubbo

    2012-01-01

    Full Text Available Object. We arranged a mini-invasive surgical approach for implantation of paddle electrodes for SCS under spinal anesthesia obtaining the best paddle electrode placement and minimizing patients’ discomfort. We describe our technique supported by neurophysiological intraoperative monitoring and clinical results. Methods. 16 patients, affected by neuropathic pain underwent the implantation of paddle electrodes for spinal cord stimulation in lateral decubitus under spinal anesthesia. The paddle was introduced after flavectomy and each patient confirmed the correct distribution of paresthesias induced by intraoperative test stimulation. VAS and patients’ satisfaction rate were recorded during the followup and compared to preoperative values. Results. No patients reported discomfort during the procedure. In all cases, paresthesias coverage of the total painful region was achieved, allowing the best final electrode positioning. At the last followup (mean 36.7 months, 87.5% of the implanted patients had a good rate of satisfaction with a mean VAS score improvement of 70.5%. Conclusions. Spinal cord stimulation under spinal anesthesia allows an optimal positioning of the paddle electrodes without any discomfort for patients or neurosurgeons. The best intraoperative positioning allows a better postoperative control of pain, avoiding the risk of blind placements of the paddle or further surgery for their replacement.

  17. Use of Retrievable Compared to Permanent Inferior Vena Cava Filters: A Single-Institution Experience

    International Nuclear Information System (INIS)

    Ha, Thuong G. Van; Chien, Andy S.; Funaki, Brian S.; Lorenz, Jonathan; Piano, Giancarlo; Shen, Maxine; Leef, Jeffrey

    2008-01-01

    The purpose of this study was to review the use, safety, and efficacy of retrievable inferior vena cava (IVC) filters in their first 5 years of availability at our institution. Comparison was made with permanent filters placed in the same period. A retrospective review of IVC filter implantations was performed from September, 1999, to September, 2004, in our department. These included both retrievable and permanent filters. The Recovery nitinol and Guenther tulip filters were used as retrievable filters. The frequency of retrievable filter used was calculated. Clinical data and technical data related to filter placement were reviewed. Outcomes, including pulmonary embolism, complications associated with placement, retrieval, or indwelling, were calculated. During the study period, 604 IVC filters were placed. Of these, 97 retrievable filters (16%) were placed in 96 patients. There were 53 Recovery filter and 44 Tulip filter insertions. Subjects were 59 women and 37 men; the mean age was 52 years, with a range of from 18 to 97 years. The placement of retrievable filters increased from 2% in year 1 to 32% in year 5 of the study period. The total implantation time for the permanent group was 145,450 days, with an average of 288 days (range, 33-1811 days). For the retrievable group, the total implantation time was 21,671 days, with an average of 226 days (range, 2-1217 days). Of 29 patients who returned for filter retrieval, the filter was successfully removed in 28. There were 14 of 14 successful Tulip filter retrievals and 14 of 15 successful Recovery filter retrievals. In one patient, after an indwelling period of 39 days, a Recovery nitinol filter could not be removed secondary to a large clot burden within the filter. For the filters that were removed, the mean dwell time was 50 days for the Tulip type and 20 days for the Recovery type. Over the follow-up period there was an overall PE incidence of 1.4% for the permanent group and 1% for the retrieval group. In

  18. Investigations on effects of the hole size to fix electrodes and interconnection lines in polydimethylsiloxane

    Science.gov (United States)

    Behkami, Saber; Frounchi, Javad; Ghaderi Pakdel, Firouz; Stieglitz, Thomas

    2017-11-01

    Translational research in bioelectronics medicine and neural implants often relies on established material assemblies made of silicone rubber (polydimethylsiloxane-PDMS) and precious metals. Longevity of the compound is of utmost importance for implantable devices in therapeutic and rehabilitation applications. Therefore, secure mechanical fixation can be used in addition to chemical bonding mechanisms to interlock PDMS substrate and insulation layers with metal sheets for interconnection lines and electrodes. One of the best ways to fix metal lines and electrodes in PDMS is to design holes in electrode rims to allow for direct interconnection between top to bottom layer silicone. Hence, the best layouts and sizes of holes (up to 6) which provide sufficient stability against lateral and vertical forces have been investigated with a variety of numbers of hole in line electrodes, which are simulated and fabricated with different layouts, sizes and materials. Best stability was obtained with radii of 100, 72 and 62 µm, respectively, and a single central hole in aluminum, platinum and MP35N foil line electrodes of 400  ×  500 µm2 size and of thickness 20 µm. The study showed that the best hole size which provides line electrode immobility (of thickness less than 30 µm) within a central hole is proportional to reverse value of Young’s Modulus of the material used. Thus, an array of line electrodes was designed and fabricated to study this effect. Experimental results were compared with simulation data. Subsequently, an approximation curve was generated as design rule to propose the best radius to fix line electrodes according to the material thickness between 10 and 200 µm using PDMS as substrate material.

  19. Trapping of deuterium in argon-implanted nickel

    International Nuclear Information System (INIS)

    Frank, R.C.; Rehn, L.E.; Baldo, P.

    1985-01-01

    Argon ions with energy 250 keV were implanted at fluences of 2 x 10 16 cm -2 at temperatures of 500, 250, and 21 0 C, in the specimen of relatively pure polycrystalline nickel. Deuterium was introduced into the surface and implanted regions by making the specimen the negative electrode of an electrolytic cell containing 1-N pure deuterated sulfuric acid. Deuterium trapped in the vacancy complexes of the implanted regions was analyzed as a function of temperature using the vacancy complexes of the implanted regions was analyzed as a function of temperature using the 2 H( 3 He, 1 H) 4 He nuclear reaction during an isochronal annealing process. The results indicate that the types of traps and trap densities found in the regions implanted at 21 and 250 0 C were essentially identical while the trap density found in the region implanted at 500 0 C was approximately 40% of that found in the other regions. Math model comparison with the experimental results suggests the existence of at least two types of traps in each region. Trap binding enthalpies used in the math model to fit the experimental data were slightly higher for the region implanted with argon at 500 0 C than for the regions implanted at the lower temperatures. TEM studies revealed the presence of small voids in the region implanted at 500 0 as well as dislocation loops similar to those found in the regions implanted at the lower temperatures. 20 references, 2 figures

  20. Fourteen-years experience with cochlear implantation in Ramathibodi Hospital.

    Science.gov (United States)

    Kasemsuwan, Lalida; Cheewaruangroj, Wichit; Tungkeeratichai, Jumroon; Bhongmakapat, Thongchai; Thawin, Cheamchit; Lertsukprasert, Krisna; Tiravanitchakul, Rattinan; Dara, Rada; Laothamatas, Jiraporn

    2010-12-01

    To review the cochlear implant program in Ramathibodi Hospital and share experience of cochlear implantation emphasized on clinical and surgical outcomes. Retrospective review of 143 ears (140 patients) operated with cochlear implant between 1995 and 2009. The demographic data including etiology of deafness and findings from temporal bone CTscans were reviewed. The authors' experience with cochlear implant surgery in terms of patient selection, patient advisory clinic, necessary equipment, pre- and postoperative evaluations, surgical techniques and complications were discussed. Most congenital origin was unknown etiology and congenital rubella was the most common known cause. From the CT scans of congenital deafness, vestibular aqueduct dilatation was the most common and found in 29.31% while Mondini malformation was shown to be 16.37%. The authors' surgical technique of using the pocket method and designed bony ridge at cortical mastoid rim had helped stabilizing the implant and electrode fancoil. During the last two years, no complication or revision surgery was detected. Cochlear implant surgery in both children and adults can result in good surgical outcome and fewer complications under experienced surgeons and a good team.

  1. Wireless radio channel for intramuscular electrode implants in the control of upper limb prostheses.

    Science.gov (United States)

    Stango, Antonietta; Yazdandoost, Kamya Yekeh; Farina, Dario

    2015-01-01

    In the last few years the use of implanted devices has been considered also in the field of myoelectric hand prostheses. Wireless implanted EMG (Electromyogram) sensors can improve the functioning of the prosthesis, providing information without the disadvantage of the wires, and the usability by amputees. The solutions proposed in the literature are based on proprietary communication protocols between the implanted devices and the prosthesis controller, using frequency bands that are already assigned to other purposes. This study proposes the use of a standard communication protocol (IEEE 802.15.6), specific for wireless body area networks (WBANs), which assign a specific bandwidth to implanted devices. The propagation losses from in-to-on body were investigated by numerical simulation with a 3D human model and an electromagnetic solver. The channel model resulting from the study represents the first step towards the development of myoelectric prosthetic hands which are driven by signals acquired by implanted sensors. However these results can provide important information to researchers for further developments, and manufacturers, which can decrease the production costs for hand prostheses having a common standard of communication with assigned frequencies of operation.

  2. SU-G-JeP1-10: Feasibility of CyberKnife Tracking Using the Previously-Implanted Permanent Brachytherapy Seed Cloud

    International Nuclear Information System (INIS)

    Cheung, J; Cunha, J; Sudhyadhom, A; McGuinness, C; Roach, M; Descovich, M

    2016-01-01

    Purpose: Robotic radiosurgery is a salvage treatment option for patients with recurrent prostate cancer. We explored the feasibility of tracking the bolus of permanent prostate implants (PPI) using image recognition software optimized to track spinal anatomy. Methods: Forty-five inert iodine seeds were implanted into a gelatin-based prostate phantom. Four superficial gold seeds were inserted to provide ground-truth alignment. A CT scan of the phantom (120 kVp, 1 mm slice thickness) was acquired and a single-energy iterative metal artifact reduction (MAR) algorithm was used to enhance the quality of the DRR used for tracking. CyberKnife treatment plans were generated from the MAR CT and regular CT (no-MAR) using spine tracking. The spine-tracking grid was centered on the bolus of seeds and resized to encompass the full seed cloud. A third plan was created from the regular CT scan, using fiducial tracking based on the 4 superficial gold seeds with identical align-center coordinates. The phantom was initially aligned using the fiducial-tracking plan. Then the MAR and no-MAR spine-tracking plans were loaded without moving the phantom. Differences in couch correction parameters were recorded in the case of perfect alignment and after the application of known rotations and translations (roll/pitch of 2 degrees; translations XYZ of 2 cm). Results: The spine tracking software was able to lock on to the bolus of seeds and provide couch corrections both in the MAR and no-MAR plans. In all cases, differences in the couch correction parameters from fiducial alignment were <0.5 mm in translations and <1 degree in rotations. Conclusion: We were able to successfully track the bolus of seeds with the spine-tracking grid in phantom experiments. For clinical applications, further investigation and developments to adapt the spine-tracking algorithm to optimize for PPI seed cloud tracking is needed to provide reliable tracking in patients. One of the authors (MD) has received research

  3. SU-G-JeP1-10: Feasibility of CyberKnife Tracking Using the Previously-Implanted Permanent Brachytherapy Seed Cloud

    Energy Technology Data Exchange (ETDEWEB)

    Cheung, J; Cunha, J; Sudhyadhom, A; McGuinness, C; Roach, M; Descovich, M [University of California San Francisco, San Francisco, CA (United States)

    2016-06-15

    Purpose: Robotic radiosurgery is a salvage treatment option for patients with recurrent prostate cancer. We explored the feasibility of tracking the bolus of permanent prostate implants (PPI) using image recognition software optimized to track spinal anatomy. Methods: Forty-five inert iodine seeds were implanted into a gelatin-based prostate phantom. Four superficial gold seeds were inserted to provide ground-truth alignment. A CT scan of the phantom (120 kVp, 1 mm slice thickness) was acquired and a single-energy iterative metal artifact reduction (MAR) algorithm was used to enhance the quality of the DRR used for tracking. CyberKnife treatment plans were generated from the MAR CT and regular CT (no-MAR) using spine tracking. The spine-tracking grid was centered on the bolus of seeds and resized to encompass the full seed cloud. A third plan was created from the regular CT scan, using fiducial tracking based on the 4 superficial gold seeds with identical align-center coordinates. The phantom was initially aligned using the fiducial-tracking plan. Then the MAR and no-MAR spine-tracking plans were loaded without moving the phantom. Differences in couch correction parameters were recorded in the case of perfect alignment and after the application of known rotations and translations (roll/pitch of 2 degrees; translations XYZ of 2 cm). Results: The spine tracking software was able to lock on to the bolus of seeds and provide couch corrections both in the MAR and no-MAR plans. In all cases, differences in the couch correction parameters from fiducial alignment were <0.5 mm in translations and <1 degree in rotations. Conclusion: We were able to successfully track the bolus of seeds with the spine-tracking grid in phantom experiments. For clinical applications, further investigation and developments to adapt the spine-tracking algorithm to optimize for PPI seed cloud tracking is needed to provide reliable tracking in patients. One of the authors (MD) has received research

  4. Low elastic modulus Ti–Ta alloys for load-bearing permanent implants: Enhancing the biodegradation resistance by electrochemical surface engineering

    Energy Technology Data Exchange (ETDEWEB)

    Kesteven, Jazmin [Biomaterials and Engineering Materials (BEM) Laboratory, School of Engineering and Physical Sciences, James Cook University, Townsville, Queensland 4811 (Australia); Kannan, M. Bobby, E-mail: bobby.mathan@jcu.edu.au [Biomaterials and Engineering Materials (BEM) Laboratory, School of Engineering and Physical Sciences, James Cook University, Townsville, Queensland 4811 (Australia); Walter, Rhys; Khakbaz, Hadis [Biomaterials and Engineering Materials (BEM) Laboratory, School of Engineering and Physical Sciences, James Cook University, Townsville, Queensland 4811 (Australia); Choe, Han-Choel [Department of Dental Materials, Chosun University, Gwangju 501-759 (Korea, Republic of)

    2015-01-01

    In this study, the in vitro degradation behaviour of titanium–tantalum (Ti–Ta) alloys (10–30 wt.% Ta) was investigated and compared with conventional implant materials, i.e., commercially pure titanium (Cp-Ti) and titanium–aluminium–vanadium (Ti6Al4V) alloy. Among the three Ti–Ta alloys studied, the Ti20Ta (6.3 × 10{sup −4} mm/y) exhibited the lowest degradation rate, followed by Ti30Ta (1.2 × 10{sup −3} mm/y) and Ti10Ta (1.4 × 10{sup −3} mm/y). All the Ti–Ta alloys exhibited lower degradation rate than that of Cp-Ti (1.8 × 10{sup −3} mm/y), which suggests that Ta addition to Ti is beneficial. As compared to Ti6Al4V alloy (8.1 × 10{sup −4} mm/y), the degradation rate of Ti20Ta alloy was lower by ∼ 22%. However, the Ti30Ta alloy, which has closer elastic modulus to that of natural bone, showed ∼ 48% higher degradation rate than that of Ti6Al4V alloy. Hence, to improve the degradation performance of Ti30Ta alloy, an intermediate thin porous layer was formed electrochemically on the alloy followed by calcium phosphate (CaP) electrodeposition. The coated Ti30Ta alloy (3.8 × 10{sup −3} mm/y) showed ∼ 53% lower degradation rate than that of Ti6Al4V alloy. Thus, the study suggests that CaP coated Ti30Ta alloy can be a viable material for load-bearing permanent implants. - Highlights: • In vitro degradation of titanium–tantalum (Ti–Ta) alloys was studied. • Ta addition to Ti is beneficial for better degradation resistance. • Ti–Ta alloys perform better than commercially pure Ti. • Calcium phosphate coated Ti–Ta alloy is superior to Ti6Al4V alloy.

  5. Wireless microsensor network solutions for neurological implantable devices

    Science.gov (United States)

    Abraham, Jose K.; Whitchurch, Ashwin; Varadan, Vijay K.

    2005-05-01

    The design and development of wireless mocrosensor network systems for the treatment of many degenerative as well as traumatic neurological disorders is presented in this paper. Due to the advances in micro and nano sensors and wireless systems, the biomedical sensors have the potential to revolutionize many areas in healthcare systems. The integration of nanodevices with neurons that are in communication with smart microsensor systems has great potential in the treatment of many neurodegenerative brain disorders. It is well established that patients suffering from either Parkinson"s disease (PD) or Epilepsy have benefited from the advantages of implantable devices in the neural pathways of the brain to alter the undesired signals thus restoring proper function. In addition, implantable devices have successfully blocked pain signals and controlled various pelvic muscles in patients with urinary and fecal incontinence. Even though the existing technology has made a tremendous impact on controlling the deleterious effects of disease, it is still in its infancy. This paper presents solutions of many problems of today's implantable and neural-electronic interface devices by combining nanowires and microelectronics with BioMEMS and applying them at cellular level for the development of a total wireless feedback control system. The only device that will actually be implanted in this research is the electrodes. All necessary controllers will be housed in accessories that are outside the body that communicate with the implanted electrodes through tiny inductively-coupled antennas. A Parkinson disease patient can just wear a hat-system close to the implantable neural probe so that the patient is free to move around, while the sensors continually monitor, record, transmit all vital information to health care specialist. In the event of a problem, the system provides an early warning to the patient while they are still mobile thus providing them the opportunity to react and

  6. [Management of surgery patients with implanted cardiac pacemakers].

    Science.gov (United States)

    Ugljen, R; Dadić, D; Ferek-Petrić, B; Jelić, I; Letica, D; Anić, D; Husar, J

    1995-01-01

    Patients having cardiac pacemaker implanted may be subjected to various general surgery procedures. Application of electrosurgery for the purpose of resection and coagulation, provides a high frequency electric field which produces electric voltage on the electrodes of the pacing system. This voltage may be detected within the pacing system, and various arrhythmias can be provoked in correlation with underlying rhythm and mode of pacing. Preoperative patient control and proper pacemaker programming can prevent the pacing malfunctions due to the electrosurgery application. Appropriate positioning of the neutral electrode in relation to the pacing system avoids the electric fields intersection and decreases their interference.

  7. Delayed changes in auditory status in cochlear implant users with preserved acoustic hearing.

    Science.gov (United States)

    Scheperle, Rachel A; Tejani, Viral D; Omtvedt, Julia K; Brown, Carolyn J; Abbas, Paul J; Hansen, Marlan R; Gantz, Bruce J; Oleson, Jacob J; Ozanne, Marie V

    2017-07-01

    This retrospective review explores delayed-onset hearing loss in 85 individuals receiving cochlear implants designed to preserve acoustic hearing at the University of Iowa Hospitals and Clinics between 2001 and 2015. Repeated measures of unaided behavioral audiometric thresholds, electrode impedance, and electrically evoked compound action potential (ECAP) amplitude growth functions were used to characterize longitudinal changes in auditory status. Participants were grouped into two primary categories according to changes in unaided behavioral thresholds: (1) stable hearing or symmetrical hearing loss and (2) delayed loss of hearing in the implanted ear. Thirty-eight percent of this sample presented with delayed-onset hearing loss of various degrees and rates of change. Neither array type nor insertion approach (round window or cochleostomy) had a significant effect on prevalence. Electrode impedance increased abruptly for many individuals exhibiting precipitous hearing loss; the increase was often transient. The impedance increases were significantly larger than the impedance changes observed for individuals with stable or symmetrical hearing loss. Moreover, the impedance changes were associated with changes in behavioral thresholds for individuals with a precipitous drop in behavioral thresholds. These findings suggest a change in the electrode environment coincident with the change in auditory status. Changes in ECAP thresholds, growth function slopes, and suprathreshold amplitudes were not correlated with changes in behavioral thresholds, suggesting that neural responsiveness in the region excited by the implant is relatively stable. Further exploration into etiology of delayed-onset hearing loss post implantation is needed, with particular interest in mechanisms associated with changes in the intracochlear environment. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Definition of medical event is to be based on the total source strength for evaluation of permanent prostate brachytherapy: A report from the American Society for Radiation Oncology.

    Science.gov (United States)

    Nag, Subir; Demanes, D Jeffrey; Hagan, Michael; Rivard, Mark J; Thomadsen, Bruce R; Welsh, James S; Williamson, Jeffrey F

    2011-10-01

    The Nuclear Regulatory Commission deems it to be a medical event (ME) if the total dose delivered differs from the prescribed dose by 20% or more. A dose-based definition of ME is not appropriate for permanent prostate brachytherapy as it generates too many spurious MEs and thereby creates unnecessary apprehension in patients, and ties up regulatory bodies and the licensees in unnecessary and burdensome investigations. A more suitable definition of ME is required for permanent prostate brachytherapy. The American Society for Radiation Oncology (ASTRO) formed a working group of experienced clinicians to review the literature, assess the validity of current regulations, and make specific recommendations about the definition of an ME in permanent prostate brachytherapy. The working group found that the current definition of ME in §35.3045 as "the total dose delivered differs from the prescribed dose by 20 percent or more" was not suitable for permanent prostate brachytherapy since the prostate volume (and hence the resultant calculated prostate dose) is dependent on the timing of the imaging, the imaging modality used, the observer variability in prostate contouring, the planning margins used, inadequacies of brachytherapy treatment planning systems to calculate tissue doses, and seed migration within and outside the prostate. If a dose-based definition for permanent implants is applied strictly, many properly executed implants would be improperly classified as an ME leading to a detrimental effect on brachytherapy. The working group found that a source strength-based criterion, of >20% of source strength prescribed in the post-procedure written directive being implanted outside the planning target volume is more appropriate for defining ME in permanent prostate brachytherapy. ASTRO recommends that the definition of ME for permanent prostate brachytherapy should not be dose based but should be based upon the source strength (air-kerma strength) administered.

  9. A temperature sensor implant for active implantable medical devices for in vivo subacute heating tests under MRI.

    Science.gov (United States)

    Silemek, Berk; Acikel, Volkan; Oto, Cagdas; Alipour, Akbar; Aykut, Zaliha Gamze; Algin, Oktay; Atalar, Ergin

    2018-05-01

    To introduce a temperature sensor implant (TSI) that mimics an active implantable medical device (AIMD) for animal testing of MRI heating. Computer simulations and phantom experiments poorly represent potential temperature increases. Animal experiments could be a better model, but heating experiments conducted immediately after the surgery suffer from alterations of the thermoregulatory and tissue properties during acute testing conditions. Therefore, the aim of this study was to introduce a temperature sensor implant that mimics an AIMD and capable of measuring the electrode temperature after implantation of the device without any further intervention at any time after the surgery in an animal model. A battery-operated TSI, which resembled an AIMD, was used to measure the lead temperature and impedance and the case temperature. The measured values were transmitted to an external computer via a low-power Bluetooth communication protocol. In addition to validation experiments on the phantom, a sheep experiment was conducted to test the feasibility of the system in subacute conditions. The measurements had a maximum of 0.5°C difference compared to fiber-optic temperature probes. In vivo animal experiments demonstrated feasibility of the system. An active implant, which can measure its own temperature, was proposed to investigate implant heating during MRI examinations. Magn Reson Med 79:2824-2832, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  10. Insertion torque recordings for the diagnosis of contact between orthodontic mini-implants and dental roots: protocol for a systematic review

    NARCIS (Netherlands)

    Meursinge Reynders, Reint; Ladu, Luisa; Ronchi, Laura; Di Girolamo, Nicola; de Lange, Jan; Roberts, Nia; Plüddemann, Annette

    2015-01-01

    Hitting a dental root during the insertion of orthodontic mini-implants (OMIs) is a common adverse effect of this intervention. This condition can permanently damage these structures and can cause implant instability. Increased torque levels (index test) recorded during the insertion of OMIs may

  11. Electrode-immobilized compounds through γ radiation

    International Nuclear Information System (INIS)

    De Castro, E.S.

    1983-01-01

    Chemically Modified Electrodes (CMEs) are used as substrates in heterogeneous catalysis and as sensors. This work demonstrates a new strategy for immobilizing polyelectrolytes and electroactive agents on electrode surfaces. The success of this method lies in cross-linking water soluble polymer chains through the ionizing radiation of γ emissions from a 60 Co source. Cross-linking can create a continuous network out of the polymer macromolecules which then makes the network insoluble on the electrode surface. Bonds between the network and the substrate are also possible. Redox species mixed with the polymer network and irradiated become part of the insoluble network, and are permanently attached. The use of γ radiation to make electrochemical sensors is demonstrated. The immobilized network poly[diallyl dimethyl ammonium chloride] (DDAC) is placed in a solution of potassium ferricyanide and ionicly exchanges the anion into the network. An electroactive network is created from irradiating a mixture of DDAC and 2,6-dichlorophenolindophenol (DCIP). Using the amount of electroactive DCIP remaining in the film as the optimization parameter, variables such as polymer:DCIP ratio, film thickness, and dosage employed are shown to be relevant

  12. Cochlear Implant

    Directory of Open Access Journals (Sweden)

    Mehrnaz Karimi

    1992-04-01

    Full Text Available People with profound hearing loss are not able to use some kinds of conventional amplifiers due to the nature of their loss . In these people, hearing sense is stimulated only when the auditory nerve is activated via electrical stimulation. This stimulation is possible through cochlear implant. In fact, for the deaf people who have good mental health and can not use surgical and medical treatment and also can not benefit from air and bone conduction hearing aids, this device is used if they have normal central auditory system. The basic parts of the device included: Microphone, speech processor, transmitter, stimulator and receiver, and electrode array.

  13. Connective tissue grafts for thickening peri-implant tissues at implant placement. One-year results from an explanatory split-mouth randomised controlled clinical trial.

    Science.gov (United States)

    Wiesner, Günter; Esposito, Marco; Worthington, Helen; Schlee, Markus

    2010-01-01

    Nothing to declare. To evaluate whether connective tissue grafts performed at implant placement could be effective in augmenting peri-implant soft tissues. Ten partially edentulous patients requiring at least one single implant in the premolar or molar areas of both sides of the mandible were randomised to have one side augmented at implant placement with a connective soft tissue graft harvested from the palate or no augmentation. After 3 months of submerged healing, abutments were placed and within 1 month definitive crowns were permanently cemented. Outcome measures were implant success, any complications, peri-implant marginal bone level changes, patient satisfaction and preference, thickness of the soft tissues and aesthetics (pink aesthetic score) evaluated by an independent and blinded assessor 1 year after loading. One year after loading, no patients dropped out, no implants failed and no complications occurred. Both groups lost statistically significant amounts of peri-implant bone 1 year after loading (0.8 mm in the grafted group and 0.6 mm in the non-grafted group), but there was no statistically significant difference between groups. Soft tissues at augmented sites were 1.3 mm thicker (P Connective tissue grafts are effective in increasing soft tissue thickness, thus improving aesthetics. Longer follow-ups are needed to evaluate the stability of peri-implant tissues over time.

  14. Flexible and stretchable electrodes for dielectric elastomer actuators

    Science.gov (United States)

    Rosset, Samuel; Shea, Herbert R.

    2013-02-01

    Dielectric elastomer actuators (DEAs) are flexible lightweight actuators that can generate strains of over 100 %. They are used in applications ranging from haptic feedback (mm-sized devices), to cm-scale soft robots, to meter-long blimps. DEAs consist of an electrode-elastomer-electrode stack, placed on a frame. Applying a voltage between the electrodes electrostatically compresses the elastomer, which deforms in-plane or out-of plane depending on design. Since the electrodes are bonded to the elastomer, they must reliably sustain repeated very large deformations while remaining conductive, and without significantly adding to the stiffness of the soft elastomer. The electrodes are required for electrostatic actuation, but also enable resistive and capacitive sensing of the strain, leading to self-sensing actuators. This review compares the different technologies used to make compliant electrodes for DEAs in terms of: impact on DEA device performance (speed, efficiency, maximum strain), manufacturability, miniaturization, the integration of self-sensing and self-switching, and compatibility with low-voltage operation. While graphite and carbon black have been the most widely used technique in research environments, alternative methods are emerging which combine compliance, conduction at over 100 % strain with better conductivity and/or ease of patternability, including microfabrication-based approaches for compliant metal thin-films, metal-polymer nano-composites, nanoparticle implantation, and reel-to-reel production of μm-scale patterned thin films on elastomers. Such electrodes are key to miniaturization, low-voltage operation, and widespread commercialization of DEAs.

  15. [Radiological trap and oncological precautions in a patient who has undergone a permanent withdrawal of PIP breast implants].

    Science.gov (United States)

    Koutsomanis, A; Bruant-Rodier, C; Roedlich, M-N; Bretz-Grenier, M-F; Perrot, P; Bodin, F

    2015-12-01

    We report the case of a 57-year-old patient who presented radiological images similar to ruptured breast implants one year after the supposed withdrawal of the latter. This woman had benefited for the first time from cosmetic PIP breast implants in 2000. Early in 2014, she requested the removal of the implants without renewal because she was feeling pain and functional discomfort. A few months after the operation, she consulted for breast swelling in the upper pole of the breast. Radiological assessment showed liquid formations compatible with the presence of implants. At our request, the rereading of the MRI by the radiologist definitively concluded on a bilateral seroma within the persistent fibrous capsule. In the absence of symptoms, clinical monitoring had been decided. But at the recrudescence of anaplastic large cell lymphoma cases associated with breast implants, a cytological sampling was intended. In case of cytological abnormality or recurrence of the seroma, a surgical procedure should be performed. In conclusion, the removal of a breast implant without capsulectomy may result in the formation of a seroma whose images resemble those of an implant. It is always worthwhile to provide precise clinical data to the radiologist in order to help him to make informed interpretations. Every serous effusion in a breast lodge having contained a silicone implant must evoke the diagnosis of anaplastic large cell lymphoma. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  16. Surface potential measurement of negative-ion-implanted insulators by analysing secondary electron energy distribution

    International Nuclear Information System (INIS)

    Toyota, Yoshitaka; Tsuji, Hiroshi; Nagumo, Syoji; Gotoh, Yasuhito; Ishikawa, Junzo; Sakai, Shigeki.

    1994-01-01

    The negative ion implantation method we have proposed is a noble technique which can reduce surface charging of isolated electrodes by a large margin. In this paper, the way to specify the surface potential of negative-ion-implanted insulators by the secondary electron energy analysis is described. The secondary electron energy distribution is obtained by a retarding field type energy analyzer. The result shows that the surface potential of fused quartz by negative-ion implantation (C - with the energy of 10 keV to 40 keV) is negatively charged by only several volts. This surface potential is extremely low compared with that by positive-ion implantation. Therefore, the negative-ion implantation is a very effective method for charge-up free implantation without charge compensation. (author)

  17. Right ventricular perforation by a passive-fixation pacemaker lead two weeks after implantation

    Directory of Open Access Journals (Sweden)

    Azeem S. Sheikh, BSc, MBBS, FCPS, MRCP

    2014-12-01

    Full Text Available Myocardial perforation is a rare complication of permanent pacemaker implantation. While most of the perforations occur at the time of implantation or within the first 24 h, delayed myocardial perforations are very rare. The clinical course is extremely variable with some patients presenting completely asymptomatic, while others can develop cardiac tamponade and haemodynamic instability. We report an unusual case of a subacute ventricular perforation caused by a passive-fixation lead two weeks after implantation and we successfully managed to extract the lead under local anaesthesia, without the patient undergoing surgery, as recommended in the previously published reports.

  18. [The evolution of surgical interventions for cochlear implantation at the Russian Research and Practical Centre of Audiology and Hearing Rehabilitation].

    Science.gov (United States)

    Fedoseev, V I; Dmitriev, N S

    2014-01-01

    The objective of the present study was to estimate and analyse the effectiveness and labour intensity of the methods of surgical intervention for cochlear implantation. The analysis of the surgical stage of cochlear implantation was based on the examination of 2073 children and adults during the period from 1991 to 2013. The age of the patients varied between 6 months to 71 years. The cause of deafness was meningitis and an injury in 11% and 6% of the patients respectively. The cochlear implants from Advanced Bionics were inserted in 495 patients, those from Med-El in 9 ones , and from Neurelec in 20, and Nucleus devices from Cochlear in the remaining patents (n=1549) including 37 double-array electrodes and a Hybrid implant for electroacoustic correction of hearing . The implants with a straight and perimodiolar electrode were placed in a roughly equal number of the patients. The rationale for the performance of selected components of the surgical stage of cochlear implantation was developed along with the technical procedures for the purpose applied at this Centre since 1991. The original methods for the fixation and covering of the receiver-stimulator and also for the choice of the place of the electrode array insertion into the cochlea are described. They allowed to significantly decrease the frequency of complications, duration and extent of the surgical intervention as well as to reduce to a minimum post-operative manipulations.

  19. Correlation analysis of the relationship between B-type natriuretic peptide and selected echocardiographic parameters in patients with permanent pacemakers

    Directory of Open Access Journals (Sweden)

    Janusz Sielski

    2016-01-01

    Full Text Available Introduction: The present study was undertaken to evaluate the practical value of BNP measurements and echocardiographic left ventricular volume index in patients with permanent pacemakers because there are no such reports in the literature. Aim of the research: The aim of the study was to reveal multiple correlations between BNP levels and selected echocardiographic parameters of the left atrium in patients with permanent pacemakers. In the literature there are reports on the significance of BNP values and left atrial size in patients with permanent pacemakers. The results of the present study appear to be of value in the outpatient assessment of these patients. Material and methods: We analysed a group of 117 patients with permanent pacemakers (AAI/R 21 patients, DDD/R 59 patients, VVI/R 37 patients and 48 healthy volunteers serving as the control group. BNP measurements were performed on venous blood samples using Triage meters. The Simpson method and the ellipse method were used to assess the left atrium on echocardiography. Results: There was a significant correlation between BNP and maximum left atrial volume, minimum left atrial volume, and left atrial volume index in patients with AAI/R, DDD/R, and VVI/R pacemakers at 3 and 6 months after the implantation. Conclusions : In patients after implantation of permanent pacemakers there are correlations between BNP values and echocardiographic left atrial parameters, especially in patients with DDD/R pacemakers. Left atrial function improves in patients with DDD/R pacemakers. Pacemaker check-up should be extended to include BNP measurements and echocardiographic assessment of the left atrium.

  20. Develop techniques for ion implantation of PLZT [lead-lanthanum-zirconate-titanate] for adaptive optics

    International Nuclear Information System (INIS)

    Batishko, C.R.; Brimhall, J.L.; Pawlewicz, W.T.; Stahl, K.A.; Toburen, L.H.

    1987-09-01

    Research was conducted at Pacific Northwest Laboratory to develop high photosensitivity adaptive optical elements utilizing ion implanted lanthanum-doped lead-zirconate-titanate (PLZT). One centimeter square samples were prepared by implanting ferroelectric and anti-ferroelectric PLZT with a variety of species or combinations of species. These included Ne, O, Ni, Ne/Cr, Ne/Al, Ne/Ni, Ne/O, and Ni/O, at a variety of energies and fluences. An indium-tin oxide (ITO) electrode coating was designed to give a balance of high conductivity and optical transmission at near uv to near ir wavelengths. Samples were characterized for photosensitivity; implanted layer thickness, index of refraction, and density; electrode (ITO) conductivity; and in some cases, residual stress curvature. Thin film anti-ferroelectric PLZT was deposited in a preliminary experiment. The structure was amorphous with x-ray diffraction showing the beginnings of a structure at substrate temperatures of approximately 550 0 C. This report summarizes the research and provides a sampling of the data taken during the report period

  1. Electroactive Ionic Soft Actuators with Monolithically Integrated Gold Nanocomposite Electrodes.

    Science.gov (United States)

    Yan, Yunsong; Santaniello, Tommaso; Bettini, Luca Giacomo; Minnai, Chloé; Bellacicca, Andrea; Porotti, Riccardo; Denti, Ilaria; Faraone, Gabriele; Merlini, Marco; Lenardi, Cristina; Milani, Paolo

    2017-06-01

    Electroactive ionic gel/metal nanocomposites are produced by implanting supersonically accelerated neutral gold nanoparticles into a novel chemically crosslinked ion conductive soft polymer. The ionic gel consists of chemically crosslinked poly(acrylic acid) and polyacrylonitrile networks, blended with halloysite nanoclays and imidazolium-based ionic liquid. The material exhibits mechanical properties similar to that of elastomers (Young's modulus ≈ 0.35 MPa) together with high ionic conductivity. The fabrication of thin (≈100 nm thick) nanostructured compliant electrodes by means of supersonic cluster beam implantation (SCBI) does not significantly alter the mechanical properties of the soft polymer and provides controlled electrical properties and large surface area for ions storage. SCBI is cost effective and suitable for the scaleup manufacturing of electroactive soft actuators. This study reports the high-strain electromechanical actuation performance of the novel ionic gel/metal nanocomposites in a low-voltage regime (from 0.1 to 5 V), with long-term stability up to 76 000 cycles with no electrode delamination or deterioration. The observed behavior is due to both the intrinsic features of the ionic gel (elasticity and ionic transport capability) and the electrical and morphological features of the electrodes, providing low specific resistance (<100 Ω cm -2 ), high electrochemical capacitance (≈mF g -1 ), and minimal mechanical stress at the polymer/metal composite interface upon deformation. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Clinical Significance of Accounting for Tissue Heterogeneity in Permanent Breast Seed Implant Brachytherapy Planning

    Energy Technology Data Exchange (ETDEWEB)

    Mashouf, Shahram [Medical Biophysics Department, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada); Department of Radiation Oncology, Sunnybrook Odette Cancer Centre, Toronto, Ontario (Canada); Fleury, Emmanuelle [Department of Radiation Oncology, Sunnybrook Odette Cancer Centre, Toronto, Ontario (Canada); Lai, Priscilla [Medical Biophysics Department, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada); Merino, Tomas [Department of Radiation Oncology, Sunnybrook Odette Cancer Centre, Toronto, Ontario (Canada); Radiotherapy Unit, School of Medicine, Departamento de Hemato-oncologia, Pontificia Universidad Católica de Chile, Santiago (Chile); Lechtman, Eli [Medical Biophysics Department, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada); Kiss, Alex [Sunnybrook Research Institute, Toronto, Ontario (Canada); McCann, Claire [Department of Radiation Oncology, Sunnybrook Odette Cancer Centre, Toronto, Ontario (Canada); Pignol, Jean-Philippe, E-mail: j.p.pignol@erasmusmc.nl [Medical Biophysics Department, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada); Department of Radiation Oncology, Sunnybrook Odette Cancer Centre, Toronto, Ontario (Canada); Radiation Oncology Department, Erasmus Medical Center, Cancer Institute, Rotterdam (Netherlands)

    2016-03-15

    Purpose: The inhomogeneity correction factor (ICF) method provides heterogeneity correction for the fast calculation TG43 formalism in seed brachytherapy. This study compared ICF-corrected plans to their standard TG43 counterparts, looking at their capacity to assess inadequate coverage and/or risk of any skin toxicities for patients who received permanent breast seed implant (PBSI). Methods and Materials: Two-month postimplant computed tomography scans and plans of 140 PBSI patients were used to calculate dose distributions by using the TG43 and the ICF methods. Multiple dose-volume histogram (DVH) parameters of clinical target volume (CTV) and skin were extracted and compared for both ICF and TG43 dose distributions. Short-term (desquamation and erythema) and long-term (telangiectasia) skin toxicity data were available on 125 and 110 of the patients, respectively, at the time of the study. The predictive value of each DVH parameter of skin was evaluated using the area under the receiver operating characteristic (ROC) curve for each toxicity endpoint. Results: Dose-volume histogram parameters of CTV, calculated using the ICF method, showed an overall decrease compared to TG43, whereas those of skin showed an increase, confirming previously reported findings of the impact of heterogeneity with low-energy sources. The ICF methodology enabled us to distinguish patients for whom the CTV V{sub 100} and V{sub 90} are up to 19% lower compared to TG43, which could present a risk of recurrence not detected when heterogeneity are not accounted for. The ICF method also led to an increase in the prediction of desquamation, erythema, and telangiectasia for 91% of skin DVH parameters studied. Conclusions: The ICF methodology has the advantage of distinguishing any inadequate dose coverage of CTV due to breast heterogeneity, which can be missed by TG43. Use of ICF correction also led to an increase in prediction accuracy of skin toxicities in most cases.

  3. New Criteria of Indication and Selection of Patients to Cochlear Implant

    Directory of Open Access Journals (Sweden)

    André L. L. Sampaio

    2011-01-01

    Full Text Available Numerous changes continue to occur in cochlear implant candidacy. In general, these have been accompanied by concomitant and satisfactory changes in surgical techniques. Together, this has advanced the utility and safety of cochlear implantation. Most devices are now approved for use in patients with severe to profound unilateral hearing loss rather then the prior requirement of a bilateral profound loss. Furthermore, studies have begun utilizing short electrode arrays for shallow insertion in patients with considerable low-frequency residual hearing. This technique will allow the recipient to continue to use acoustically amplified hearing for the low frequencies simultaneously with a cochlear implant for the high frequencies. The advances in design of, and indications for, cochlear implants have been matched by improvements in surgical techniques and decrease in complications. The resulting improvements in safety and efficacy have further encouraged the use of these devices. This paper will review the new concepts in the candidacy of cochlear implant. Medline data base was used to search articles dealing with the following topics: cochlear implant in younger children, cochlear implant and hearing preservation, cochlear implant for unilateral deafness and tinnitus, genetic hearing loss and cochlear implant, bilateral cochlear implant, neuropathy and cochlear implant and neural plasticity, and the selection of patients for cochlear implant.

  4. Planar self-aligned ion implanted InP MISFETS for fast logic applications

    International Nuclear Information System (INIS)

    Cameron, D.C.; Irving, L.D.; Whitehouse, C.R.; Woodward, J.; Lee, D.

    1983-01-01

    The first successful use of ion implantation to fabricate truly self-aligned planar n-channel enhancement-mode indium phosphide MISFITS is reported. The transistors have been fabricated on iron-doped semi-insulating material using PECVD-deposited SiO 2 as the gate dielectric and molybdenum gate electrodes. The self-aligned source and drain contact regions were produced by Si 29 ion implantation using each gate stripe as an implant mask. The devices fabricated to date have exhibited channel mobilities up to value of 2400 cm 2 v -1 s -1 , with excellent uniformity and stability of the device characteristics also being observed. (author)

  5. Implantable power generation system utilizing muscle contractions excited by electrical stimulation.

    Science.gov (United States)

    Sahara, Genta; Hijikata, Wataru; Tomioka, Kota; Shinshi, Tadahiko

    2016-06-01

    An implantable power generation system driven by muscle contractions for supplying power to active implantable medical devices, such as pacemakers and neurostimulators, is proposed. In this system, a muscle is intentionally contracted by an electrical stimulation in accordance with the demands of the active implantable medical device for electrical power. The proposed system, which comprises a small electromagnetic induction generator, electrodes with an electrical circuit for stimulation and a transmission device to convert the linear motion of the muscle contractions into rotational motion for the magneto rotor, generates electrical energy. In an ex vivo demonstration using the gastrocnemius muscle of a toad, which was 28 mm in length and weighed 1.3 g, the electrical energy generated by the prototype exceeded the energy consumed for electrical stimulation, with the net power being 111 µW. It was demonstrated that the proposed implantable power generation system has the potential to replace implantable batteries for active implantable medical devices. © IMechE 2016.

  6. Loudness growth observed under partially tripolar stimulation: model and data from cochlear implant listeners.

    Science.gov (United States)

    Litvak, Leonid M; Spahr, Anthony J; Emadi, Gulam

    2007-08-01

    Most cochlear implant strategies utilize monopolar stimulation, likely inducing relatively broad activation of the auditory neurons. The spread of activity may be narrowed with a tripolar stimulation scheme, wherein compensating current of opposite polarity is simultaneously delivered to two adjacent electrodes. In this study, a model and cochlear implant subjects were used to examine loudness growth for varying amounts of tripolar compensation, parameterized by a coefficient sigma, ranging from 0 (monopolar) to 1 (full tripolar). In both the model and the subjects, current required for threshold activation could be approximated by I(sigma)=Ithr(0)(1-sigmaK), with fitted constants Ithr(0) and K. Three of the subjects had a "positioner," intended to place their electrode arrays closer to their neural tissue. The values of K were smaller for the positioner users and for a "close" electrode-to-tissue distance in the model. Above threshold, equal-loudness contours for some subjects deviated significantly from a linear scale-up of the threshold approximations. The patterns of deviation were similar to those observed in the model for conditions in which most of the neurons near the center electrode were excited.

  7. Rehabilitation of deaf persons with cochlear implants

    International Nuclear Information System (INIS)

    Gstoettner, W.; Hamzavi, J.; Czerny, C.

    1997-01-01

    In the last decade, the rehabilitation of postlingually deaf adults and prelingually deaf children with cochlear implants has been established as a treatment of deafness. The technological development of the implant devices and improvement of the surgical technique have led to a considerable increase of hearing performance during the last years. The postlingually deaf adults are able to use the telephone and may be integrated in their original job. Prelingually deaf children can even visit normal schools after cochlear implantation and hearing rehabilitation training. In order to preoperatively establish the state of the cochlear, radiological diagnosis of the temporal bone is necessary. High resolution computerized tomography imaging of the temporal bone with coronar and axial 1 mm slices and MRI with thin slice technique (three dimensional, T2 weighted turbo-spinecho sequence with 0.7 mm slices) have proved to be valuable according to our experience. Furthermore a postoperative synoptical X-ray, in a modified Chausse III projection, offers good information about the position of the implant and insertion of the stimulating electrode into the cochlea. (orig.) [de

  8. A mini axial and a permanent maglev radial heart pump.

    Science.gov (United States)

    Qian, Kun-Xi; Ru, Wei-Min; Wang, Hao; Jing, Teng

    2007-05-31

    The implantability and durability have been for decades the focus of artificial heart R&D. A mini axial and a maglev radial pump have been developed to meet with such requirements.The mini axial pump weighing 27g (incl.5g rotor) has an outer diameter of 21mm and a length of 10mm in its largest point, but can produce a maximal blood flow of 6l/min with 50mmHg pressure increase. Therefore, it is suitable for the patients of 40-60kg body weight. For other patients of 60-80kg or 80-100kg body weight, the mini axial pumps of 23mm and 25mm outer diameter had been developed before, these devices were acknowledged to be the world smallest LVADs by Guinness World Record Center in 2004.The permanent maglev radial pump weighing 150g is a shaft-less centrifugal pump with permanent magnetic bearings developed by the author. It needs no second coil for suspension of the rotor except the motor coil, different from all other maglev pumps developed in USA, Japan, European, etc. Thus no detecting and controlling systems as well as no additional power supply for maglev are necessary. The pump can produce a blood flow up to as large as 10l/min against 100mmHg pressure.An implantable and durable blood pump will be a viable alternative to natural donor heart for transplantation.

  9. Immediate provisional restoration of a single-tooth implant in the esthetic zone: A case report

    Directory of Open Access Journals (Sweden)

    Po-Sung Fu

    2011-02-01

    Full Text Available Immediate implant restoration of single implants may demonstrate a positive effect on peri-implant soft tissue. Placement of a provisional restoration following implant surgery can create soft tissue contours that resemble normal gingival topography before placement of the definitive prosthesis. This article describes a staged approach of the mandibular permanent right central incisor, which was congenital missing. The proper space for restoration of the missing incisor was created through orthodontic treatment. The scheduled implant site was reconstructed using autogenous bone harvested from the chin region. After a healing period of four months, an implant was installed with the connection of a fixed provisional crown to a prefabricated temporary abutment. The soft tissue around the implant healed according to the contours of the provisional restoration and the emergence profile was used to duplicate the definitive restoration. Peri-implant esthetics was achieved through the staged approach and immediate restoration of the implant.

  10. Trends in Intraoperative Testing During Cochlear Implantation.

    Science.gov (United States)

    Page, Joshua Cody; Cox, Matthew D; Hollowoa, Blake; Bonilla-Velez, Juliana; Trinidade, Aaron; Dornhoffer, John L

    2018-03-01

    No consensus guidelines exist regarding intraoperative testing during cochlear implantation and wide variation in practice habits exists. The objective of this observational study was to survey otologists/neurotologists to understand practice habits and overall opinion of usefulness of intraoperative testing. Cross-sectional survey. A web-based survey was sent to 194 practicing Otologists/Neurotologists. Questions included practice setting and experience, habits with respect to electrodes used, intraoperative testing modalities used, overall opinion of intraoperative testing, and practice habits in various scenarios. Thirty-nine of 194 (20%) completed the survey. For routine patients, ECAPs and EIs were most commonly used together (38%) while 33% do not perform testing at all. Eighty-nine percent note that testing "rarely" or "never" changes management. Fifty-one percent marked the most important reason for testing is the reassurance provided to the family and/or the surgeon. Intraoperative testing habits and opinions regarding testing during cochlear implantation vary widely among otologic surgeons. The majority of surgeons use testing but many think there is minimal benefit and that surgical decision-making is rarely impacted. The importance of testing may change as electrodes continue to evolve.

  11. Systematic review: Radiological and histological evidence of cochlear implant insertion trauma in adult patients.

    Science.gov (United States)

    Hoskison, Emma; Mitchell, Scott; Coulson, Chris

    2017-07-01

    Cochlear implantation (CI) has developed from its origins in the 1980s. Initially, CI was for profound bilateral hearing impairment. However, candidacy for CI have become more widespread in recent years with unilateral implantation and an emphasis on hearing preservation. Evidence supports full electrode insertion in an atraumatic fashion into the scala tympani (ST) provides optimal hearing outcomes. The main aim of this systematic review was to elucidate the degree of trauma associated with CI insertion. A systematic literature search was undertaken using PubMed Medline. A grading system described by Eshraghi was used to classify cochlear trauma. Both radiological and histological studies were included. Twenty one papers were identified which were relevant to our search. In total, 653 implants were inserted and 115 (17.6%) showed evidence of trauma. The cochleas with trauma had basilar membrane elevation in 5.2%, ruptured in 5.2%, the electrode passed from the ST to the SV in 84.4% and there was grade 4 trauma in 5.2%. The studies used a variety of histological and radiological methods to assess for evidence of trauma in both cadaveric temporal bones and live recipients. Minimizing cochlear trauma during implant insertion is important to preserve residual hearing and optimize audiological performance. An overall 17.6% trauma rate suggests that CI insertion could be improved with more accurate and consistent electrode insertion such as in the form of robotic guidance. The correlation of cochlea trauma with post-operative hearing has yet to be determined.

  12. Volume study pre and post-implant brachytherapy prostate for establishment of PTV margins; Estudio de volumenes pre y post-implante en braquiterapia de prostata para establecimiento de margenes del PTV

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez Dominguez, M.; Carrasco Herrera, M.; Baeza Trujillo, M.; Herrador Cordoba, M.

    2011-07-01

    Treatment of prostate cancer by permanent implantation of radioactive seeds is now a good alternative to radical surgery or radiotherapy, as it provides a good tumor control while the risk is reduced by a lower complication irradiation of adjacent healthy organs. The large volume change during seed implantation occurs in the prostate of the patient, makes it important to consider margins around the organs of interest both to ensure optimal coverage and minimal tumor irradiation of healthy tissue. Analyze how the volume varies during and after implantation and establish a margin around the prostate to the practice of our hospital are the two objectives of this work.

  13. Across-site patterns of electrically evoked compound action potential amplitude-growth functions in multichannel cochlear implant recipients and the effects of the interphase gap.

    Science.gov (United States)

    Schvartz-Leyzac, Kara C; Pfingst, Bryan E

    2016-11-01

    Electrically evoked compound action potential (ECAP) measures of peak amplitude, and amplitude-growth function (AGF) slope have been shown to reflect characteristics of cochlear health (primarily spiral ganglion density) in anesthetized cochlear-implanted guinea pigs. Likewise, the effect of increasing the interphase gap (IPG) in each of these measures also reflects SGN density in the implanted guinea pig. Based on these findings, we hypothesize that suprathreshold ECAP measures, and also how they change as the IPG is increased, have the potential to be clinically applicable in human subjects. However, further work is first needed in order to determine the characteristics of these measures in humans who use cochlear implants. The current study examined across-site patterns of suprathreshold ECAP measures in 10 bilaterally-implanted, adult cochlear implant users. Results showed that both peak amplitude and slope of the AGF varied significantly from electrode to electrode in ear-specific patterns across the subjects' electrode arrays. As expected, increasing the IPG on average increased the peak amplitude and slope. Across ears, there was a significant, negative correlation between the slope of the ECAP AGF and the duration of hearing loss. Across-site patterns of ECAP peak amplitude and AGF slopes were also compared with common ground impedance values and significant correlations were observed in some cases, depending on the subject and condition. The results of this study, coupled with previous studies in animals, suggest that it is feasible to measure the change in suprathreshold ECAP measures as the IPG increases on most electrodes. Further work is needed to investigate the relationship between these measures and cochlear implant outcomes, and determine how these measures might be used when programming a cochlear-implant processor. Published by Elsevier B.V.

  14. Surgical Results and Complications of Cochlear Implantation in Far-Advanced Otosclerosis

    DEFF Research Database (Denmark)

    West, Niels; Brand, Markus; Foghsgaard, Søren

    2017-01-01

    OBJECTIVE: To report surgical results and complications of cochlear implantation in patients with far-advanced otosclerosis (FAO). MATERIALS AND METHODS: This was a retrospective chart review of surgical results in terms of electrode insertion as well as peri- and postoperative complications. Ten...

  15. Friction coefficient and effective interference at the implant-bone interface.

    Science.gov (United States)

    Damm, Niklas B; Morlock, Michael M; Bishop, Nicholas E

    2015-09-18

    Although the contact pressure increases during implantation of a wedge-shaped implant, friction coefficients tend to be measured under constant contact pressure, as endorsed in standard procedures. Abrasion and plastic deformation of the bone during implantation are rarely reported, although they define the effective interference, by reducing the nominal interference between implant and bone cavity. In this study radial forces were analysed during simulated implantation and explantation of angled porous and polished implant surfaces against trabecular bone specimens, to determine the corresponding friction coefficients. Permanent deformation was also analysed to determine the effective interference after implantation. For the most porous surface tested, the friction coefficient initially increased with increasing normal contact stress during implantation and then decreased at higher contact stresses. For a less porous surface, the friction coefficient increased continually with normal contact stress during implantation but did not reach the peak magnitude measured for the rougher surface. Friction coefficients for the polished surface were independent of normal contact stress and much lower than for the porous surfaces. Friction coefficients were slightly lower for pull-out than for push-in for the porous surfaces but not for the polished surface. The effective interference was as little as 30% of the nominal interference for the porous surfaces. The determined variation in friction coefficient with radial contact force, as well as the loss of interference during implantation will enable a more accurate representation of implant press-fitting for simulations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Excitation Patterns of Standard and Steered Partial Tripolar Stimuli in Cochlear Implants

    OpenAIRE

    Wu, Ching-Chih; Luo, Xin

    2015-01-01

    Current steering in partial tripolar (pTP) mode has been shown to improve pitch perception and spectral resolution with cochlear implants (CIs). In this mode, a fraction (?) of the main electrode current is returned within the cochlea and steered between the basal and apical flanking electrodes (with a proportion of ? and 1????, respectively). Pitch generally decreases when ? increases from 0 to 1, although the salience of pitch change varies across CI users. This study aimed to identify the ...

  17. OptoZIF Drive: a 3D printed implant and assembly tool package for neural recording and optical stimulation in freely moving mice

    Science.gov (United States)

    Freedman, David S.; Schroeder, Joseph B.; Telian, Gregory I.; Zhang, Zhengyang; Sunil, Smrithi; Ritt, Jason T.

    2016-12-01

    Objective. Behavioral neuroscience studies in freely moving rodents require small, light-weight implants to facilitate neural recording and stimulation. Our goal was to develop an integrated package of 3D printed parts and assembly aids for labs to rapidly fabricate, with minimal training, an implant that combines individually positionable microelectrodes, an optical fiber, zero insertion force (ZIF-clip) headstage connection, and secondary recording electrodes, e.g. for electromyography (EMG). Approach. Starting from previous implant designs that position recording electrodes using a control screw, we developed an implant where the main drive body, protective shell, and non-metal components of the microdrives are 3D printed in parallel. We compared alternative shapes and orientations of circuit boards for electrode connection to the headstage, in terms of their size, weight, and ease of wire insertion. We iteratively refined assembly methods, and integrated additional assembly aids into the 3D printed casing. Main results. We demonstrate the effectiveness of the OptoZIF Drive by performing real time optogenetic feedback in behaving mice. A novel feature of the OptoZIF Drive is its vertical circuit board, which facilities direct ZIF-clip connection. This feature requires angled insertion of an optical fiber that still can exit the drive from the center of a ring of recording electrodes. We designed an innovative 2-part protective shell that can be installed during the implant surgery to facilitate making additional connections to the circuit board. We use this feature to show that facial EMG in mice can be used as a control signal to lock stimulation to the animal’s motion, with stable EMG signal over several months. To decrease assembly time, reduce assembly errors, and improve repeatability, we fabricate assembly aids including a drive holder, a drill guide, an implant fixture for microelectode ‘pinning’, and a gold plating fixture. Significance. The

  18. Handcrafted Electrocorticography Electrodes for a Rodent Behavioral Model

    Directory of Open Access Journals (Sweden)

    Nishat Tasnim

    2016-08-01

    Full Text Available Electrocorticography (ECoG is a minimally invasive neural recording method that has been extensively used for neuroscience applications. It has proven to have the potential to ease the establishment of proper links for neural interfaces that can offer disabled patients an alternative solution for their lost sensory and motor functions through the use of brain-computer interface (BCI technology. Although many neural recording methods exist, ECoG provides a combination of stability, high spatial and temporal resolution with chronic and mobile capabilities that could make BCI systems accessible for daily applications. However, many ECoG electrodes require MEMS fabricating techniques which are accompanied by various expenses that are obstacles for research projects. For this reason, this paper presents an animal study using a low cost and simple handcrafted ECoG electrode that is made of commercially accessible materials. The study is performed on a Lewis rat implanted with a handcrafted 32-channel non-penetrative ECoG electrode covering an area of 3 × 3 mm2 on the cortical surface. The ECoG electrodes were placed on the motor and somatosensory cortex to record the signal patterns while the animal was active on a treadmill. Using a Tucker-Davis Technologies acquisition system and the software Synapse to monitor and analyze the electrophysiological signals, the electrodes obtained signals within the amplitude range of 200 µV for local field potentials with reliable spatiotemporal profiles. It was also confirmed that the handcrafted ECoG electrode has the stability and chronic features found in other commercial electrodes.

  19. Construction of implantable optical fibers for long-term optogenetic manipulation of neural circuits.

    Science.gov (United States)

    Sparta, Dennis R; Stamatakis, Alice M; Phillips, Jana L; Hovelsø, Nanna; van Zessen, Ruud; Stuber, Garret D

    2011-12-08

    In vivo optogenetic strategies have redefined our ability to assay how neural circuits govern behavior. Although acutely implanted optical fibers have previously been used in such studies, long-term control over neuronal activity has been largely unachievable. Here we describe a method to construct implantable optical fibers to readily manipulate neural circuit elements with minimal tissue damage or change in light output over time (weeks to months). Implanted optical fibers readily interface with in vivo electrophysiological arrays or electrochemical detection electrodes. The procedure described here, from implant construction to the start of behavioral experimentation, can be completed in approximately 2-6 weeks. Successful use of implantable optical fibers will allow for long-term control of mammalian neural circuits in vivo, which is integral to the study of the neurobiology of behavior.

  20. SECOND MOLAR UPRIGHTING AFTER PREMATURE LOSS OF MANDIBULAR FIRST PERMANENT MOLAR--CASE REPORT.

    Science.gov (United States)

    Cernei, E R; Mavru, R B; Zetui, Irina Nicoleta

    2015-01-01

    Uprighting a tipped molar by using an uprighting spring is a fundamental orthodontic treatment technique. Following a weak anchorage done only by the anterior teeth the permanent lower second molar will rotate around its center of resistance, and besides the distalizing movement will occur its extrusion. Following the reaction, the mandibular anterior teeth will have a movement of intrusion. All these elements will lead to anterior open bite. Correction of vertical problems has become easier with the advent of mini-implants. U.I patient aged 24 years presenting for aesthetic and functional disorders. Clinical examination reveals intraoral Class I molar malocclusion on the right sight, upper narrowing arch with a slight overbite, and the both permanent first molars on the left side lost prematurely. The tooth 37 is inclined at 600 degrees to the plane of occlusion. To avoid front opening occlusion we used an orthodontic miniscrew inserted between the canine and the first premolar on the same side to achieve the second molar up righting. Lower second molar uprighting was achieved without unwanted movements in anterior mandibular region and without molar extrusion. Using mini implants in uprighting a tipped molar will achieve the desired tooth movement and will reduce the number of unwanted side effects and eventually to improve patient's esthetics.

  1. The cochlear implant as a tinnitus treatment.

    Science.gov (United States)

    Vallés-Varela, Héctor; Royo-López, Juan; Carmen-Sampériz, Luis; Sebastián-Cortés, José M; Alfonso-Collado, Ignacio

    2013-01-01

    Tinnitus is a symptom of high prevalence in patients with cochlear pathology. We studied the evolution of tinnitus in patients undergoing unilateral cochlear implantation for treatment of profound hearing loss. This was a longitudinal, retrospective study of patients that underwent unilateral cochlear implantation and who had bilateral tinnitus. Tinnitus was assessed quantitatively and qualitatively before surgery and at 6 and 12 months after surgery. We evaluated 20 patients that underwent unilateral cochlear implantation with a Nucleus(®) CI24RE Contour Advance™ electrode device. During the periods in which the device was in operation, improvement or disappearance of tinnitus was evidenced in the ipsilateral ear in 65% of patients, and in the contralateral ear, in 50%. In periods in which the device was disconnected, improvement or disappearance of tinnitus was found in the ipsilateral ear in 50% of patients, and in the ear contralateral to the implant in 45% of the patients. In 10% of the patients, a new tinnitus appeared in the ipsilateral ear. The patients with profound hearing loss and bilateral tinnitus treated with unilateral cochlear implantation improved in a high percentage of cases, in the ipsilateral ear and in the contralateral ear. Copyright © 2012 Elsevier España, S.L. All rights reserved.

  2. AUDITORY NUCLEI: DISTINCTIVE RESPONSE PATTERNS TO WHITE NOISE AND TONES IN UNANESTHETIZED CATS.

    Science.gov (United States)

    GALIN, D

    1964-10-09

    Electrical responses to "white" noise and tonal stimuli were recorded from unanesthetized cats with permanently implanted bipolar electrodes. The cochlear nucleus, inferior colliculus, and medial geniculate each showed distinctive patterns of evoked activity. White noise and tones produced qualitatively different types of response. A decrease in activity characterized the response of the inferior colliculus to tonal stimuli.

  3. In vitro assessment of tissue heating near metallic medical implants by exposure to pulsed radio frequency diathermy

    Energy Technology Data Exchange (ETDEWEB)

    Ruggera, P S; Witters, D M; Maltzahn, G von; Bassen, H I [Center for Devices and Radiological Health, Food and Drug Administration, HFZ-133, 9200 Corporate Blvd., Rockville, MD 20850 (United States)

    2003-09-07

    A patient with bilateral implanted neurostimulators suffered significant brain tissue damage, and subsequently died, following diathermy treatment to hasten recovery from teeth extraction. Subsequent MRI examinations showed acute deterioration of the tissue near the deep brain stimulator (DBS) lead's electrodes which was attributed to excessive tissue heating induced by the diathermy treatment. Though not published in the open literature, a second incident was reported for a patient with implanted neurostimulators for the treatment of Parkinson's disease. During a diathermy treatment for severe kyphosis, the patient had a sudden change in mental status and neurological deficits. The diathermy was implicated in causing damage to the patient's brain tissue. To investigate if diathermy induced excessive heating was possible with other types of implantable lead systems, or metallic implants in general, we conducted a series of in vitro laboratory tests. We obtained a diathermy unit and also assembled a controllable laboratory exposure system. Specific absorption rate (SAR) measurements were performed using fibre optic thermometry in proximity to the implants to determine the rate of temperature rise using typical diathermy treatment power levels. Comparisons were made of the SAR measurements for a spinal cord stimulator (SCS) lead, a pacemaker lead and three types of bone prosthesis (screws, rods and a plate). Findings indicate that temperature changes of 2.54 and 4.88 deg. C s{sup -1} with corresponding SAR values of 9129 and 17 563 W kg{sup -1} near the SCS and pacemaker electrodes are significantly higher than those found in the proximity of the other metallic implants which ranged from 0.04 to 0.69 deg C s{sup -1} (129 to 2471 W kg{sup -1}). Since the DBS leads that were implanted in the reported human incidents have one-half the electrode surface area of the tested SCS lead, these results imply that tissue heating at rates at least equal to or up to

  4. In vitro assessment of tissue heating near metallic medical implants by exposure to pulsed radio frequency diathermy

    International Nuclear Information System (INIS)

    Ruggera, P S; Witters, D M; Maltzahn, G von; Bassen, H I

    2003-01-01

    A patient with bilateral implanted neurostimulators suffered significant brain tissue damage, and subsequently died, following diathermy treatment to hasten recovery from teeth extraction. Subsequent MRI examinations showed acute deterioration of the tissue near the deep brain stimulator (DBS) lead's electrodes which was attributed to excessive tissue heating induced by the diathermy treatment. Though not published in the open literature, a second incident was reported for a patient with implanted neurostimulators for the treatment of Parkinson's disease. During a diathermy treatment for severe kyphosis, the patient had a sudden change in mental status and neurological deficits. The diathermy was implicated in causing damage to the patient's brain tissue. To investigate if diathermy induced excessive heating was possible with other types of implantable lead systems, or metallic implants in general, we conducted a series of in vitro laboratory tests. We obtained a diathermy unit and also assembled a controllable laboratory exposure system. Specific absorption rate (SAR) measurements were performed using fibre optic thermometry in proximity to the implants to determine the rate of temperature rise using typical diathermy treatment power levels. Comparisons were made of the SAR measurements for a spinal cord stimulator (SCS) lead, a pacemaker lead and three types of bone prosthesis (screws, rods and a plate). Findings indicate that temperature changes of 2.54 and 4.88 deg. C s -1 with corresponding SAR values of 9129 and 17 563 W kg -1 near the SCS and pacemaker electrodes are significantly higher than those found in the proximity of the other metallic implants which ranged from 0.04 to 0.69 deg C s -1 (129 to 2471 W kg -1 ). Since the DBS leads that were implanted in the reported human incidents have one-half the electrode surface area of the tested SCS lead, these results imply that tissue heating at rates at least equal to or up to twice as much as those reported

  5. SU-F-19A-11: Retrospective Evaluation of Thermal Coverage by Thermobrachytherapy Seed Arrangements of Clinical LDR Prostate Implants

    Energy Technology Data Exchange (ETDEWEB)

    Warrell, G; Shvydka, D; Chen, C; Parsai, E [University of Toledo Medical Center, Toledo, OH (United States)

    2014-06-15

    Purpose: The superiority of a properly-administered combination of radiation therapy and hyperthermia over radiation alone in treatment of human cancers has been demonstrated in multiple studies examining radiobiology, local control, and survival. Unfortunately, hyperthermia is not yet a common modality in oncology practice, due in part to the technical difficulty of heating a deep-seated target volume to sufficient temperature. To address this problem, our group has invented a thermobrachytherapy (TB) seed based on a commonly-used low dose-rate permanent brachytherapy seed for implant in solid tumors. Instead of the tungsten radiographic marker of the standard seed, the TB seed contains one of a self-regulating ferromagnetic alloy. Placement of a patient implanted with such seeds in an oscillating magnetic field generates heat via induction of eddy currents. We present the results of studies of the capability of clinically-realistic TB seed arrangements to adequately heat defined target volumes. Methods: Seed distributions for several past LDR prostate permanent implant brachytherapy patients were reproduced in the finite element analysis software package COMSOL Multiphysics 4.4, with the difference that TB seeds were modelled, rather than the radiation-only seeds actually used for their treatments. The implant geometries were mainly of the modified peripheral loading type; a range of prostatic volumes and blood perfusion rates likely to be seen in a clinical setting were examined. Results: According to the simulations, when distributed to optimize radiation dose, TB seeds also produce sufficient heat to provide thermal coverage of the target given proper selection of the magnetic field strength. However, the thermal distributions may be improved by additional use of hyperthermia-only seeds. Conclusion: A dual-modality seed intended as an alternative to and using the same implantation apparatus and technique as the standard LDR permanent implant seed has been

  6. A Mini Axial and a Permanent Maglev Radial Heart Pump§

    Science.gov (United States)

    Qian, Kun-Xi; Ru, Wei-Min; Wang, Hao; Jing, Teng

    2007-01-01

    The implantability and durability have been for decades the focus of artificial heart R&D. A mini axial and a maglev radial pump have been developed to meet with such requirements. The mini axial pump weighing 27g (incl.5g rotor) has an outer diameter of 21mm and a length of 10mm in its largest point, but can produce a maximal blood flow of 6l/min with 50mmHg pressure increase. Therefore, it is suitable for the patients of 40-60kg body weight. For other patients of 60-80kg or 80-100kg body weight, the mini axial pumps of 23mm and 25mm outer diameter had been developed before, these devices were acknowledged to be the world smallest LVADs by Guinness World Record Center in 2004. The permanent maglev radial pump weighing 150g is a shaft-less centrifugal pump with permanent magnetic bearings developed by the author. It needs no second coil for suspension of the rotor except the motor coil, different from all other maglev pumps developed in USA, Japan, European, etc. Thus no detecting and controlling systems as well as no additional power supply for maglev are necessary. The pump can produce a blood flow up to as large as 10l/min against 100mmHg pressure. An implantable and durable blood pump will be a viable alternative to natural donor heart for transplantation. PMID:19662120

  7. A fully implantable rodent neural stimulator

    Science.gov (United States)

    Perry, D. W. J.; Grayden, D. B.; Shepherd, R. K.; Fallon, J. B.

    2012-02-01

    The ability to electrically stimulate neural and other excitable tissues in behaving experimental animals is invaluable for both the development of neural prostheses and basic neurological research. We developed a fully implantable neural stimulator that is able to deliver two channels of intra-cochlear electrical stimulation in the rat. It is powered via a novel omni-directional inductive link and includes an on-board microcontroller with integrated radio link, programmable current sources and switching circuitry to generate charge-balanced biphasic stimulation. We tested the implant in vivo and were able to elicit both neural and behavioural responses. The implants continued to function for up to five months in vivo. While targeted to cochlear stimulation, with appropriate electrode arrays the stimulator is well suited to stimulating other neurons within the peripheral or central nervous systems. Moreover, it includes significant on-board data acquisition and processing capabilities, which could potentially make it a useful platform for telemetry applications, where there is a need to chronically monitor physiological variables in unrestrained animals.

  8. PET Mapping for Brain-Computer Interface Stimulation of the Ventroposterior Medial Nucleus of the Thalamus in Rats with Implanted Electrodes.

    Science.gov (United States)

    Zhu, Yunqi; Xu, Kedi; Xu, Caiyun; Zhang, Jiacheng; Ji, Jianfeng; Zheng, Xiaoxiang; Zhang, Hong; Tian, Mei

    2016-07-01

    Brain-computer interface (BCI) technology has great potential for improving the quality of life for neurologic patients. This study aimed to use PET mapping for BCI-based stimulation in a rat model with electrodes implanted in the ventroposterior medial (VPM) nucleus of the thalamus. PET imaging studies were conducted before and after stimulation of the right VPM. Stimulation induced significant orienting performance. (18)F-FDG uptake increased significantly in the paraventricular thalamic nucleus, septohippocampal nucleus, olfactory bulb, left crus II of the ansiform lobule of the cerebellum, and bilaterally in the lateral septum, amygdala, piriform cortex, endopiriform nucleus, and insular cortex, but it decreased in the right secondary visual cortex, right simple lobule of the cerebellum, and bilaterally in the somatosensory cortex. This study demonstrated that PET mapping after VPM stimulation can identify specific brain regions associated with orienting performance. PET molecular imaging may be an important approach for BCI-based research and its clinical applications. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  9. Low-Gain, Low-Noise Integrated Neuronal Amplifier for Implantable Artifact-Reduction Recording System

    OpenAIRE

    Zbrzeski, Adeline; Lewis, Noëlle; Rummens, Francois; Jung, Ranu; N'Kaoua, Gilles; Benazzouz, Abdelhamid; Renaud, Sylvie

    2013-01-01

    Brain neuroprostheses for neuromodulation are being designed to monitor the neural activity of the brain in the vicinity of the region being stimulated using a single macro-electrode. Using a single macro-electrode, recent neuromodulation studies show that recording systems with a low gain neuronal amplifier and successive amplifier stages can reduce or reject stimulation artifacts. These systems were made with off-the-shelf components that are not amendable for future implant design. A low-g...

  10. Effect of Acupuncture on Post-implant Paresthesia

    OpenAIRE

    Sant’Anna, Crischina Branco Marques; Zuim, Paulo Renato Junqueira; Brandini, Daniela Atili; Guiotti, Aimée Maria; Vieira, Joao Batista; Turcio, Karina Helga Leal

    2017-01-01

    Paresthesia is defined as an alteration in local sensibility, associated with numbness, tingling, or unpleasant sensations caused by nerve lesions or irritation. It can be temporary or permanent. The treatment protocol for facial paresthesia is primarily based on the use of drugs and implant removal, which may not be completely effective or may require other risk exposure when there is no spontaneous regression. However, other therapeutic modalities such as acupuncture can be used. The aim of...

  11. Treatment of Rigid Hammer-Toe Deformity: Permanent Versus Removable Implant Selection.

    Science.gov (United States)

    Doty, Jesse F; Fogleman, Jason A

    2018-03-01

    Hammer-toe deformities that fail nonoperative treatment can be successfully addressed with proximal interphalangeal joint resection arthroplasty or fusion. The goal of surgery is to eliminate the deformity and rigidly fix the toe in a well-aligned position. Hammer-toe correction procedures can be performed with temporary Kirschner wire (K-wire) fixation for 3 to 6 weeks with high success rates. Pain relief with successful hammer-toe correction approaches 90%; patient satisfaction rates approximate 84%. Although complication rates are rare in most series, there remains a concern regarding exposed temporary K-wire fixation, which has led to the development of multiple permanent internal fixation options. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Intracochlear Position of Cochlear Implants Determined Using CT Scanning versus Fitting Levels: Higher Threshold Levels at Basal Turn

    NARCIS (Netherlands)

    Beek, F.B. van der; Briaire, J.J.; Marel, K.S. van der; Verbist, B.M.; Frijns, J.H.

    2016-01-01

    OBJECTIVES: In this study, the effects of the intracochlear position of cochlear implants on the clinical fitting levels were analyzed. DESIGN: A total of 130 adult subjects who used a CII/HiRes 90K cochlear implant with a HiFocus 1/1J electrode were included in the study. The insertion angle and

  13. Washable and Reliable Textile Electrodes Embedded into Underwear Fabric for Electrocardiography (ECG Monitoring

    Directory of Open Access Journals (Sweden)

    Amale Ankhili

    2018-02-01

    Full Text Available A medical quality electrocardiogram (ECG signal is necessary for permanent monitoring, and an accurate heart examination can be obtained from instrumented underwear only if it is equipped with high-quality, flexible, textile-based electrodes guaranteeing low contact resistance with the skin. The main objective of this article is to develop reliable and washable ECG monitoring underwear able to record and wirelessly send an ECG signal in real time to a smart phone and further to a cloud. The article focuses on textile electrode design and production guaranteeing optimal contact impedance. Therefore, different types of textile fabrics were coated with modified poly(3,4-ethylenedioxythiophene:poly(styrenesulfonate (PEDOT:PSS in order to develop and manufacture reliable and washable textile electrodes assembled to female underwear (bras, by sewing using commercially available conductive yarns. Washability tests of connected underwear containing textile electrodes and conductive threads were carried out up to 50 washing cycles. The influence of standardized washing cycles on the quality of ECG signals and the electrical properties of the textile electrodes were investigated and characterized.

  14. Washable and Reliable Textile Electrodes Embedded into Underwear Fabric for Electrocardiography (ECG) Monitoring.

    Science.gov (United States)

    Ankhili, Amale; Tao, Xuyuan; Cochrane, Cédric; Coulon, David; Koncar, Vladan

    2018-02-07

    A medical quality electrocardiogram (ECG) signal is necessary for permanent monitoring, and an accurate heart examination can be obtained from instrumented underwear only if it is equipped with high-quality, flexible, textile-based electrodes guaranteeing low contact resistance with the skin. The main objective of this article is to develop reliable and washable ECG monitoring underwear able to record and wirelessly send an ECG signal in real time to a smart phone and further to a cloud. The article focuses on textile electrode design and production guaranteeing optimal contact impedance. Therefore, different types of textile fabrics were coated with modified poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) in order to develop and manufacture reliable and washable textile electrodes assembled to female underwear (bras), by sewing using commercially available conductive yarns. Washability tests of connected underwear containing textile electrodes and conductive threads were carried out up to 50 washing cycles. The influence of standardized washing cycles on the quality of ECG signals and the electrical properties of the textile electrodes were investigated and characterized.

  15. Tinnitus after Simultaneous and Sequential Bilateral Cochlear Implantation.

    Science.gov (United States)

    Ramakers, Geerte G J; Kraaijenga, Véronique J C; Smulders, Yvette E; van Zon, Alice; Stegeman, Inge; Stokroos, Robert J; Free, Rolien H; Frijns, Johan H M; Huinck, Wendy J; Van Zanten, Gijsbert A; Grolman, Wilko

    2017-01-01

    suppression of tinnitus compared with their unilateral situation. While bilateral cochlear implantation can have a positive effect on preoperative tinnitus complaints, the induction of (temporary or permanent) tinnitus was also reported. Dutch Trial Register NTR1722.

  16. Cytotoxicity evaluation of polymer-derived ceramics for pacemaker electrode applications.

    Science.gov (United States)

    Grossenbacher, Jonas; Gullo, Maurizio R; Dalcanale, Federico; Blugan, Gurdial; Kuebler, Jakob; Lecaudé, Stéphanie; Tevaearai Stahel, Hendrik; Brugger, Juergen

    2015-11-01

    Ceramics are known to be chemically stable, and the possibility to electrically dope polymer-derived ceramics makes it a material of interest for implantable electrode applications. We investigated cytotoxic characteristics of four polymer-derived ceramic candidates with either electrically conductive or insulating properties. Cytotoxicity was assessed by culturing C2C12 myoblast cells under two conditions: by exposing them to material extracts and by putting them directly in contact with material samples. Cell spreading was optically evaluated by comparing microscope observations immediately after the materials insertion and after 24 h culturing. Cell viability (MTT) and mortality (LDH) were quantified after 24-h incubation in contact with the materials. Comparison was made with biocompatible positive references (alumina, platinum, biocompatible stainless steel 1.4435), negative references (latex, stainless steel 1.4301) and controls (no material present in the culture wells). We found that the cytotoxic properties of tested ceramics are comparable to established reference materials. These ceramics, which are reported to be very stable, can be microstructured and electrically doped to a wide range of conductivity and are thus excellent candidates for implantable electrode applications including pacemakers. © 2015 Wiley Periodicals, Inc.

  17. Current steering with partial tripolar stimulation mode in cochlear implants.

    Science.gov (United States)

    Wu, Ching-Chih; Luo, Xin

    2013-04-01

    The large spread of excitation is a major cause of poor spectral resolution for cochlear implant (CI) users. Partial tripolar (pTP) mode has been proposed to reduce current spread by returning an equally distributed fraction (0.5 × σ) of current to two flanking electrodes and the rest to an extra-cochlear ground. This study tested the efficacy of incorporating current steering into pTP mode to add spectral channels. Different proportions of current [α × σ and (1 - α) × σ] were returned to the basal and apical flanking electrodes respectively to shape the electric field. Loudness and pitch perception with α from 0 to 1 in steps of 0.1 was simulated with a computational model of CI stimulation and tested on the apical, middle, and basal electrodes of six CI subjects. The highest σ allowing for full loudness growth within the implant compliance limit was chosen for each main electrode. Pitch ranking was measured between pairs of loudness-balanced steered pTP stimuli with an α interval of 0.1 at the most comfortable level. Results demonstrated that steered pTP stimuli with α around 0.5 required more current to achieve equal loudness than those with α around 0 or 1, maybe due to more focused excitation patterns. Subjects usually perceived decreasing pitches as α increased from 0 to 1, somewhat consistent with the apical shift of the center of gravity of excitation pattern in the model. Pitch discrimination was not better with α around 0.5 than with α around 0 or 1, except for some subjects and electrodes. For three subjects with better pitch discrimination, about half of the pitch ranges of two adjacent main electrodes overlapped with each other in steered pTP mode. These results suggest that current steering with focused pTP mode may improve spectral resolution and pitch perception with CIs.

  18. Implant-Retained Overdentures for Young Children With Severe Oligodontia : A Series of Four Cases

    NARCIS (Netherlands)

    Filius, Marieke A. P.; Vissink, Arjan; Raghoebar, Gerry M.; Visser, Anita

    Purpose: The treatment need is high in children with severe oligodontia and anodontia, because they often have functional and esthetic problems owing to missing teeth. Because the intraforaminal region barely grows after eruption of the permanent mandibular incisors, dental implant treatment should

  19. Human Kinematics of Cochlear Implant Surgery: An Investigation of Insertion Micro-Motions and Speed Limitations.

    Science.gov (United States)

    Kesler, Kyle; Dillon, Neal P; Fichera, Loris; Labadie, Robert F

    2017-09-01

    Objectives Document human motions associated with cochlear implant electrode insertion at different speeds and determine the lower limit of continuous insertion speed by a human. Study Design Observational. Setting Academic medical center. Subjects and Methods Cochlear implant forceps were coupled to a frame containing reflective fiducials, which enabled optical tracking of the forceps' tip position in real time. Otolaryngologists (n = 14) performed mock electrode insertions at different speeds based on recommendations from the literature: "fast" (96 mm/min), "stable" (as slow as possible without stopping), and "slow" (15 mm/min). For each insertion, the following metrics were calculated from the tracked position data: percentage of time at prescribed speed, percentage of time the surgeon stopped moving forward, and number of direction reversals (ie, going from forward to backward motion). Results Fast insertion trials resulted in better adherence to the prescribed speed (45.4% of the overall time), no motion interruptions, and no reversals, as compared with slow insertions (18.6% of time at prescribed speed, 15.7% stopped time, and an average of 18.6 reversals per trial). These differences were statistically significant for all metrics ( P implant electrode at 15 mm/min is not feasible for human operators. The lower limit of continuous forward insertion is 52 mm/min on average. Guidelines on manual insertion kinematics should consider this practical limit of human motion.

  20. Biodegradable magnesium-based implants in bone studied by synchrotron radiation microtomography

    Science.gov (United States)

    Moosmann, Julian; Zeller-Plumhoff, Berit; Wieland, D. C. Florian; Galli, Silvia; Krüger, Diana; Dose, Thomas; Burmester, Hilmar; Wilde, Fabian; Bech, Martin; Peruzzi, Niccolò; Wiese, Björn; Hipp, Alexander; Beckmann, Felix; Hammel, Jörg; Willumeit-Römer, Regine

    2017-09-01

    Permanent implants made of titanium or its alloys are the gold standard in many orthopedic and traumatological applications due to their good biocompatibility and mechanical properties. However, a second surgical intervention is required for this kind of implants as they have to be removed in the case of children that are still growing or on patient's demand. Therefore, magnesium-based implants are considered for medical applications as they are degraded under physiological conditions. The major challenge is tailoring the degradation in a manner that is suitable for a biological environment and such that stabilization of the bone is provided for a controlled period. In order to understand failure mechanisms of magnesium-based implants in orthopedic applications and, further, to better understand the osseointegration, screw implants in bone are studied under mechanical load by means of a push-out device installed at the imaging beamline P05 of PETRA III at DESY. Conventional absorption contrast microtomography and phasecontrast techniques are applied in order to monitor the bone-to-implant interface under increasing load conditions. In this proof-of-concept study, first results from an in situ push-out experiment are presented.

  1. Low-Gain, Low-Noise Integrated Neuronal Amplifier for Implantable Artifact-Reduction Recording System

    Directory of Open Access Journals (Sweden)

    Abdelhamid Benazzouz

    2013-09-01

    Full Text Available Brain neuroprostheses for neuromodulation are being designed to monitor the neural activity of the brain in the vicinity of the region being stimulated using a single macro-electrode. Using a single macro-electrode, recent neuromodulation studies show that recording systems with a low gain neuronal amplifier and successive amplifier stages can reduce or reject stimulation artifacts. These systems were made with off-the-shelf components that are not amendable for future implant design. A low-gain, low-noise integrated neuronal amplifier (NA with the capability of recording local field potentials (LFP and spike activity is presented. In vitro and in vivo characterizations of the tissue/electrode interface, with equivalent impedance as an electrical model for recording in the LFP band using macro-electrodes for rodents, contribute to the NA design constraints. The NA occupies 0.15 mm2 and dissipates 6.73 µW, and was fabricated using a 0.35 µm CMOS process. Test-bench validation indicates that the NA provides a mid-band gain of 20 dB and achieves a low input-referred noise of 4 µVRMS. Ability of the NA to perform spike recording in test-bench experiments is presented. Additionally, an awake and freely moving rodent setup was used to illustrate the integrated NA ability to record LFPs, paving the pathway for future implantable systems for neuromodulation.

  2. [Sacral neuromodulation in urology - development and current status].

    Science.gov (United States)

    Schwalenberg, T; Stolzenburg, J-U; Kriegel, C; Gonsior, A

    2012-01-01

    Sacral neuromodulation (SNM) in urology is employed to treat refractory lower urinary tract dysfunction as well as chronic pelvic pain. Electrical stimulation of the sacral afferents (S2 - S4) causes activation and conditioning of higher autonomic and somatic neural structures and thereby influences the efferents controlling the urinary bladder, the rectum and their related sphincter systems. It is therefore possible to treat overactivity as well as hypocontractility and functional bladder neck obstruction. SNM treatment is conducted biphasically. Initially, test electrodes are placed to evaluate changes in micturition and pain parameters. If, in this first phase - called peripheral nerve evaluation (PNE test) - sufficient improvements are observed, the patient progresses to phase two which involves implantation of the permanent electrodes and impulse generator system. In recent years, the "two stage approach" with initial implantation of the permanent electrodes has been favoured as it increases treatment success rates. Long-term success rates of SNM vary significantly in the literature (50 - 80 %) due to heterogeneous patient populations as well as improved surgical approaches. With the introduction of "tined lead electrodes" (2002), tissue damage is reduced to a minimum. Technical innovation, financial feasibility (reimbursed in Germany since 2004) and wider application, especially in otherwise therapy-refractory patients or complex dysfunctions of the pelvis, have established SNM as a potent treatment option in urology. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Cochlear Dummy Electrodes for Insertion Training and Research Purposes: Fabrication, Mechanical Characterization, and Experimental Validation

    Directory of Open Access Journals (Sweden)

    Jan-Philipp Kobler

    2015-01-01

    Full Text Available To develop skills sufficient for hearing preservation cochlear implant surgery, surgeons need to perform several electrode insertion trials in ex vivo temporal bones, thereby consuming relatively expensive electrode carriers. The objectives of this study were to evaluate the insertion characteristics of cochlear electrodes in a plastic scala tympani model and to fabricate radio opaque polymer filament dummy electrodes of equivalent mechanical properties. In addition, this study should aid the design and development of new cochlear electrodes. Automated insertion force measurement is a new technique to reproducibly analyze and evaluate the insertion dynamics and mechanical characteristics of an electrode. Mechanical properties of MED-EL’s FLEX28, FLEX24, and FLEX20 electrodes were assessed with the help of an automated insertion tool. Statistical analysis of the overall mechanical behavior of the electrodes and factors influencing the insertion force are discussed. Radio opaque dummy electrodes of comparable characteristics were fabricated based on insertion force measurements. The platinum-iridium wires were replaced by polymer filament to provide sufficient stiffness to the electrodes and to eradicate the metallic artifacts in X-ray and computed tomography (CT images. These low-cost dummy electrodes are cheap alternatives for surgical training and for in vitro, ex vivo, and in vivo research purposes.

  4. Effect of technological advances on cochlear implant performance in adults.

    Science.gov (United States)

    Lenarz, Minoo; Joseph, Gert; Sönmez, Hasibe; Büchner, Andreas; Lenarz, Thomas

    2011-12-01

    To evaluate the effect of technological advances in the past 20 years on the hearing performance of a large cohort of adult cochlear implant (CI) patients. Individual, retrospective, cohort study. According to technological developments in electrode design and speech-processing strategies, we defined five virtual intervals on the time scale between 1984 and 2008. A cohort of 1,005 postlingually deafened adults was selected for this study, and their hearing performance with a CI was evaluated retrospectively according to these five technological intervals. The test battery was composed of four standard German speech tests: Freiburger monosyllabic test, speech tracking test, Hochmair-Schulz-Moser (HSM) sentence test in quiet, and HSM sentence test in 10 dB noise. The direct comparison of the speech perception in postlingually deafened adults, who were implanted during different technological periods, reveals an obvious improvement in the speech perception in patients who benefited from the recent electrode designs and speech-processing strategies. The major influence of technological advances on CI performance seems to be on speech perception in noise. Better speech perception in noisy surroundings is strong proof for demonstrating the success rate of new electrode designs and speech-processing strategies. Standard (internationally comparable) speech tests in noise should become an obligatory part of the postoperative test battery for adult CI patients. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.

  5. Biologically effective dose for permanent prostate brachytherapy taking into account postimplant edema

    International Nuclear Information System (INIS)

    Gellekom, Marion P.R. van; Moerland, Marinus A.; Kal, Henk B.; Battermann, Jan J.

    2002-01-01

    Purpose: To study the influence of radiobiologic and physical parameters and parameters related to edema on the biologically effective dose (BED) for permanent prostate implants and to determine the optimal timing of seed reconstruction for BED calculation. Methods and Materials: On the basis of the linear-quadratic model, an expression for the BED was derived, including the edema parameters. A set of parameter values was defined, and these parameter values were varied one at a time to examine the effect on the BED and the theoretically effective treatment time (t eff ). A ratio ε was defined to investigate the optimal timing of seed reconstruction. Results: The maximal BED decreases when the extent of lethal damage is smaller, the potential tumor doubling time is smaller, the half-life time of the seeds is shorter, and the magnitude of prostate volume increase is larger. For 125 I, the optimal timing of seed reconstruction is 25 days after implantation. Seed reconstruction 1 day after the implantation results in an underestimation of the BED of at most 43%, depending on the magnitude and half-life of edema. An overestimation of the BED of at most 22% is calculated when seed reconstruction took place at the effective treatment time. Conclusion: The maximal BED depends strongly on the value of α, the potential tumor doubling time, and the choice of isotope. If prostate volume increase due to edema is not taken into account, the BED will be underestimated shortly after the implantation and overestimated if the calculations are based on images taken several months after implantation. The optimal timing of BED evaluation for 125 I seed implants and typical prostate edema values is 25 days after implantation

  6. A novel fabrication method of carbon electrodes using 3D printing and chemical modification process.

    Science.gov (United States)

    Tian, Pan; Chen, Chaoyang; Hu, Jie; Qi, Jin; Wang, Qianghua; Chen, Jimmy Ching-Ming; Cavanaugh, John; Peng, Yinghong; Cheng, Mark Ming-Cheng

    2017-11-23

    Three-dimensional (3D) printing is an emerging technique in the field of biomedical engineering and electronics. This paper presents a novel biofabrication method of implantable carbon electrodes with several advantages including fast prototyping, patient-specific and miniaturization without expensive cleanroom. The method combines stereolithography in additive manufacturing and chemical modification processes to fabricate electrically conductive carbon electrodes. The stereolithography allows the structures to be 3D printed with very fine resolution and desired shapes. The resin is then chemically modified to carbon using pyrolysis to enhance electrochemical performance. The electrochemical characteristics of 3D printing carbon electrodes are assessed by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The specific capacitance of 3D printing carbon electrodes is much higher than the same sized platinum (Pt) electrode. In-vivo electromyography (EMG) recording, 3D printing carbon electrodes exhibit much higher signal-to-noise ratio (40.63 ± 7.73) than Pt electrodes (14.26 ± 6.83). The proposed biofabrication method is envisioned to enable 3D printing in many emerging applications in biomedical engineering and electronics.

  7. Implantable Medical Device for Measuring Electrocardiogram to Improve Human Wellness

    Directory of Open Access Journals (Sweden)

    Jong-Ha Lee

    2017-06-01

    Full Text Available Prolonged monitoring is more likely to diagnose atrial fibrillation accurately than intermittent or short-term monitoring. In this study, an implantable electrocardiograph (ECG sensor to monitor atrial fibrillation patients in real time was developed. The implantable sensor is composed of a micro controller unit, an analog-to-digital converter, a signal transmitter, an antenna, and two electrodes. The sensor detects ECG signals from the two electrodes and transmits these to an external receiver carried by the patient. Because the sensor continuously transmits signals, its battery consumption rate is extremely high; therefore, the sensor includes a wireless power transmission module that allows it to charge wirelessly from an external power source. The integrated sensor has the approximate dimensions 0.12 in × 1.18 in × 0.19 in, which is small enough to be inserted into a patient without the need for major surgery. The signal and power transmission data sampling rate and frequency of the unit are 300 samples/s and 430 Hz, respectively. To validate the developed sensor, experiments were conducted on small animals.

  8. Processing of microCT implant-bone systems images using Fuzzy Mathematical Morphology

    International Nuclear Information System (INIS)

    Bouchet, A; Pastore, J; Colabella, L; Omar, S; Ballarre, J

    2016-01-01

    The relationship between a metallic implant and the existing bone in a surgical permanent prosthesis is of great importance since the fixation and osseointegration of the system leads to the failure or success of the surgery. Micro Computed Tomography is a technique that helps to visualize the structure of the bone. In this study, the microCT is used to analyze implant-bone systems images. However, one of the problems presented in the reconstruction of these images is the effect of the iron based implants, with a halo or fluorescence scattering distorting the micro CT image and leading to bad 3D reconstructions. In this work we introduce an automatic method for eliminate the effect of AISI 316L iron materials in the implant-bone system based on the application of Compensatory Fuzzy Mathematical Morphology for future investigate about the structural and mechanical properties of bone and cancellous materials. (paper)

  9. Conduction disorders in the setting of transcatheter aortic valve implantation: a clinical perspective.

    Science.gov (United States)

    Fraccaro, Chiara; Napodano, Massimo; Tarantini, Giuseppe

    2013-06-01

    The presence of periprocedural conduction disorders (CDs) and the need for permanent pacemaker (PPM) after transcatheter aortic valve implantation (TAVI) are frequent findings in clinical practice. Notwithstanding, robust information on the prognostic and therapeutic implications of these complications are lacking. The newly occurrence of CD after TAVI seems related to the trauma of the conduction system during procedure. On the contrary, major predictors for PPM implantation after TAVI seem to be the use of CoreValve prosthesis (Medtronic, Minneapolis, MN) and the presence of CD before TAVI. An accurate pre-TAVI screening, careful valve implantation, as well as post-TAVI monitoring must be pursued to prevent avoidable PPM implantation. The aim of this report is to analyze the available data on this field and to propose some practical clinical tips to prevent or to manage these complications. Copyright © 2013 Wiley Periodicals, Inc.

  10. Penile prosthesis implant: scientific advances and technological innovations over the last four decades.

    Science.gov (United States)

    Chung, Eric

    2017-02-01

    Despite introduction of oral phosphodiesterase type 5 inhibitors and intracavernosal vasoactive agents, penile prosthesis implant remains a relevant and desired option with sales of penile prostheses continue to stay high, as many men became refractory to medical therapy and/or seeking a more effective and permanent therapy. There are two types of penile prosthesis implants: inflatable and non-inflatable types, and the inflatable penile implants can be subdivided into single-, two- and three-piece devices. Non-inflatable penile prosthesis (non-IPP) may be referred to as semi-rigid rod or malleable prosthesis. IPP is considered a superior option to malleable prosthesis as it produces penile rigidity and flaccidity that closely replicates a normal penile erectile function. Since the introduction of IPP by Scott in 1973, surgical landscape for penile prosthesis implantation has changed dramatically. Advances in prosthesis design, device technologies and surgical techniques have made penile prosthesis implant a more natural, durable and reliable device. The following article reviews the scientific advances and technological innovation in modern penile prosthesis implants over the last four decades.

  11. Anesthetic Management and Complications of Percutaneous Aortic Valve Implantation

    Directory of Open Access Journals (Sweden)

    Tailur Alberto Grando

    2013-05-01

    Full Text Available Background and objective: Aortic stenosis is a highly prevalent and life-threatening disease. In elderly patients with comorbidities, percutaneous valve implantation is an option. The aim of the study was to describe the anesthetic management and complications of general anesthesia Method: Case series with 30-day and 24-month follow-ups after implantation of the CoreValve device performed at the Institute of Cardiology/University Foundation of Cardiology between December 2008 and January 2012. The patients underwent general anesthesia monitored with mean arterial pressure (PAM, electrocardiogram (ECG, pulse oximetry, capnography, transesophageal echocardiography, thermometry, and transvenous pacemaker. Results: Twenty-eight patients, mean age 82.46 years, 20.98% mean EuroSCORE, functional class III/IV, successfully underwent valve implantation. Nine patients required permanent pacemaker implantation. During follow-up, two patients died: one during surgery due to LV perforation and the other on the third day of unknown causes. At 24 months, one patient diagnosed with multiple myeloma died. This anesthetic technique proved to be safe. Conclusion: The initial experience with percutaneous aortic valve implantation under general anesthesia has proven to be safe and effective, with no significant anesthetic complications during this procedure. Keywords: Aesthesia, General, Cardiac Surgical Procedures, Aortic Valve Stenosis, Aged.

  12. The effect of sealer and water storage on permanent deformation of a tissue conditioner

    Directory of Open Access Journals (Sweden)

    Rafael Leonardo Xediek Consani

    2008-01-01

    Full Text Available When they are used to treat inflamed, irritated, or distorted tissues or in implant therapy, tissue conditioners are required to function over relatively long time periods. Purpose: This in vitro study evaluated the effect of sealer and water storage on permanent deformation one tissue conditioner. Material and methods: Sixty cylindrically-shaped specimens (12.7-mm diameter 3 19.0-mm height were used for the deformation tests. Specimens were divided into 6 test groups (n=10, according to surface treatment (sealer application and water storage (1 hour, 1 week and 2 weeks. Permanent deformation, expressed as a percent (%, was determined using ADA specification no. 18. Data were examined a analysis of variance and a Mann-Whitney test (a= 0.05. Results: Significant differences were observed only after 1 week of water storage, for both groups. The surface treated group presented the highest permanent deformation percentage. Conclusions: This in vitro study indicated that the tissue conditioner evaluated is only useful for 1 week. After this period, the material must be replaced.

  13. Effect of axial magnetic field on a 2.45 GHz permanent magnet ECR ion source.

    Science.gov (United States)

    Nakamura, T; Wada, H; Asaji, T; Furuse, M

    2016-02-01

    Herein, we conduct a fundamental study to improve the generation efficiency of a multi-charged ion source using argon. A magnetic field of our electron cyclotron resonance ion source is composed of a permanent magnet and a solenoid coil. Thereby, the axial magnetic field in the chamber can be tuned. Using the solenoid coil, we varied the magnetic field strength in the plasma chamber and measured the ion beam current extracted at the electrode. We observed an approximately three times increase in the Ar(4+) ion beam current when the magnetic field on the extractor-electrode side of the chamber was weakened. From our results, we can confirm that the multi-charged ion beam current changes depending on magnetic field intensity in the plasma chamber.

  14. Effect of axial magnetic field on a 2.45 GHz permanent magnet ECR ion source

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, T., E-mail: tsubasa@oshima-k.ac.jp; Wada, H.; Furuse, M. [National Institute of Technology, Oshima College, 1091-1 Komatsu, Suouoshima, Oshima, Yamaguchi 742-2193 (Japan); Asaji, T. [National Institute of Technology, Toyama College, 13 Hongo, Toyama 939-8630 (Japan)

    2016-02-15

    Herein, we conduct a fundamental study to improve the generation efficiency of a multi-charged ion source using argon. A magnetic field of our electron cyclotron resonance ion source is composed of a permanent magnet and a solenoid coil. Thereby, the axial magnetic field in the chamber can be tuned. Using the solenoid coil, we varied the magnetic field strength in the plasma chamber and measured the ion beam current extracted at the electrode. We observed an approximately three times increase in the Ar{sup 4+} ion beam current when the magnetic field on the extractor-electrode side of the chamber was weakened. From our results, we can confirm that the multi-charged ion beam current changes depending on magnetic field intensity in the plasma chamber.

  15. Neuroversion: using electroconvulsive therapy as a bridge to deep brain stimulation implantation.

    Science.gov (United States)

    Williams, Nolan R; Sahlem, Greg; Pannu, Jaspreet; Takacs, Istvan; Short, Baron; Revuelta, Gonzalo; George, Mark S

    2017-02-01

    Parkinson's disease (PD) is a movement disorder with significant neuropsychiatric comorbidities. Electroconvulsive therapy (ECT) is effective in treating these neuropsychiatric symptoms; however, clinicians are reluctant to use ECT in patients with deep brain stimulation (DBS) implantations for fear of damaging the device, as well as potential cognitive side effects. Right unilateral ultra-brief pulse (RUL UBP) ECT has a more favorable cognitive side-effect profile yet has never been reported in PD patients with DBS implants. We present a case series of three patients with a history of PD that all presented with psychiatric decompensation immediately prior to planned DBS surgery. All three patients had DBS electrode(s) in place at the time and an acute course of ECT was utilized in a novel method to "bridge" these individuals to neurosurgery. The patients all experienced symptom resolution (psychosis and/or depression and/or anxiety) without apparent cognitive side effects. This case series not only illustrates that right unilateral ultra-brief pulse can be utilized in patients with DBS electrodes but also illustrates that this intervention can be utilized as a neuromodulatory "bridge", where nonoperative surgical candidates with unstable psychiatric symptoms can be converted to operative candidates in a manner similar to electrical cardioversion.

  16. Does exchange arthroplasty of an infected shoulder prosthesis provide better eradication rate and better functional outcome, compared to a permanent spacer or resection arthroplasty? a systematic review.

    Science.gov (United States)

    George, D A; Volpin, A; Scarponi, S; Haddad, F S; Romanò, C L

    2016-02-01

    The best surgical modality for treating chronic periprosthetic shoulder infections has not been established, with a lack of randomised comparative studies. This systematic review compares the infection eradication rate and functional outcomes after single- or two-stage shoulder exchange arthroplasty, to permanent spacer implant or resection arthroplasty. Full-text papers and those with an abstract in English published from January 2000 to June 2014, identified through international databases, such as EMBASE and PubMed, were reviewed. Those reporting the success rate of infection eradication after a single-stage exchange, two-stage exchange, resection arthroplasty or permanent spacer implant, with a minimum follow-up of 6 months and sample size of 5 patients were included. Eight original articles reporting the results after resection arthroplasty (n = 83), 6 on single-stage exchange (n = 75), 13 on two-stage exchange (n = 142) and 8 papers on permanent spacer (n = 68) were included. The average infection eradication rate was 86.7 % at a mean follow-up of 39.8 months (SD 20.8) after resection arthroplasty, 94.7 % at 46.8 months (SD 17.6) after a single-stage exchange, 90.8 % at 37.9 months (SD 12.8) after two-stage exchange, and 95.6 % at 31.0 months (SD 9.8) following a permanent spacer implant. The difference was not statistically significant (p = 0.650). Regarding functional outcome, patients treated with single-stage exchange had statistically significant better postoperative Constant scores (mean 51, SD 13) than patients undergoing a two-stage exchange (mean 44, SD 9), resection arthroplasty (mean 32, SD 7) or a permanent spacer implant (mean 31, SD 9) (p = 0.029). However, when considering studies comparing pre- and post-operative Constant scores, the difference was not statistically significant. This systematic review failed to demonstrate a clear difference in infection eradication and functional improvement between all four

  17. Measurements of RF Heating during 3.0T MRI of a Pig Implanted with Deep Brain Stimulator

    Science.gov (United States)

    Gorny, Krzysztof R; Presti, Michael F; Goerss, Stephan J; Hwang, Sun C; Jang, Dong-Pyo; Kim, Inyong; Shu, Yunhong; Favazza, Christopher P; Lee, Kendall H; Bernstein, Matt A

    2012-01-01

    Purpose To present preliminary, in vivo temperature measurements during MRI of a pig implanted with a deep brain stimulation (DBS) system. Materials and Methods DBS system (Medtronic Inc., Minneapolis, MN) was implanted in the brain of an anesthetized pig. 3.0T MRI was performed with a T/R head coil using the low-SAR GRE EPI and IR-prepped GRE sequences (SAR: 0.42 W/kg and 0.39 W/kg, respectively), and the high-SAR 4-echo RF spin echo (SAR: 2.9 W/kg). Fluoroptic thermometry was used to directly measure RF-related heating at the DBS electrodes, and at the implantable pulse generator (IPG). For reference the measurements were repeated in the same pig at 1.5T and, at both field strengths, in a phantom. Results At 3.0T, the maximal temperature elevations at DBS electrodes were 0.46 °C and 2.3 °C, for the low- and high-SAR sequences, respectively. No heating was observed on the implanted IPG during any of the measurements. Measurements of in-vivo heating differed from those obtained in the phantom. Conclusion The 3.0T MRI using GRE EPI and IR-prepped GRE sequences resulted in local temperature elevations at DBS electrodes of no more than 0.46°C. Although no extrapolation should be made to human exams and much further study will be needed, these preliminary data are encouraging for the future use 3.0T MRI in patients with DBS. PMID:23228310

  18. Measurements of RF heating during 3.0-T MRI of a pig implanted with deep brain stimulator.

    Science.gov (United States)

    Gorny, Krzysztof R; Presti, Michael F; Goerss, Stephan J; Hwang, Sun C; Jang, Dong-Pyo; Kim, Inyong; Min, Hoon-Ki; Shu, Yunhong; Favazza, Christopher P; Lee, Kendall H; Bernstein, Matt A

    2013-06-01

    To present preliminary, in vivo temperature measurements during MRI of a pig implanted with a deep brain stimulation (DBS) system. DBS system (Medtronic Inc., Minneapolis, MN) was implanted in the brain of an anesthetized pig. 3.0-T MRI was performed with a T/R head coil using the low-SAR GRE EPI and IR-prepped GRE sequences (SAR: 0.42 and 0.39 W/kg, respectively), and the high-SAR 4-echo RF spin echo (SAR: 2.9 W/kg). Fluoroptic thermometry was used to directly measure RF-related heating at the DBS electrodes, and at the implantable pulse generator (IPG). For reference the measurements were repeated in the same pig at 1.5 T and, at both field strengths, in a phantom. At 3.0T, the maximal temperature elevations at DBS electrodes were 0.46 °C and 2.3 °C, for the low- and high-SAR sequences, respectively. No heating was observed on the implanted IPG during any of the measurements. Measurements of in vivo heating differed from those obtained in the phantom. The 3.0-T MRI using GRE EPI and IR-prepped GRE sequences resulted in local temperature elevations at DBS electrodes of no more than 0.46 °C. Although no extrapolation should be made to human exams and much further study will be needed, these preliminary data are encouraging for the future use 3.0-T MRI in patients with DBS. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. Permanent pacing in infants and children: A single center experience in implantation and follow up

    Directory of Open Access Journals (Sweden)

    Rania Samir

    2011-09-01

    Conclusion: Permanent pacing in pediatric age group is relatively safe. However, there is substantial higher incidence of suboptimal pacing parameters and pacing system failures especially in younger and smaller children. Epicardial steroid eluting leads are comparable to endocardial steroid eluting leads in performance.

  20. Study of electrochemical properties of thin film materials obtained using plasma technologies for production of electrodes for pacemakers

    International Nuclear Information System (INIS)

    Obrezkov, O I; Vinogradov, V P; Krauz, V I; Mozgrin, D V; Guseva, I A; Andreev, E S; Zverev, A A; Starostin, A L

    2016-01-01

    Studies of thin film materials (TFM) as coatings of tips of pacemaker electrodes implanted into the human heart have been performed. TFM coatings were deposited in vacuum by arc magnetron discharge plasma, by pulsed discharge of “Plasma Focus”, and by electron beam evaporation. Simulation of electric charge transfer to the heart in physiological blood- imitator solution and determination of electrochemical properties of the coatings were carried out. TFM of highly developed surface of contact with tissue was produced by argon plasma spraying of titanium powder with subsequent coating by titanium nitride in vacuum arc assisted by Ti ion implantation. The TFM coatings of pacemaker electrode have passed necessary clinical tests and were used in medical practice. They provide low voltage myocardium stimulation thresholds within the required operating time. (paper)

  1. Dental implants in patients with ectodermal dysplasia: A systematic review.

    Science.gov (United States)

    Chrcanovic, Bruno Ramos

    2018-05-21

    This study sought to assess the clinical outcome and survival rate of oral implants placed in individuals with ectodermal dysplasia (ED), based on previously published studies. An electronic search without time restrictions was undertaken in 5 databases (PubMed/Medline, Web of Science, ScienceDirect, J-Stage, Lilacs). Descriptive statistics, Kaplan Meier estimator and implant failure probability were calculated. 90 publications were included, reporting 228 ED patients that received 1472 implants (1392 conventional, 47 zygomatic, 33 mini-implants). Mean age of the patients was 20.2 ± 6.8 years (2-56). Patients had a mean of 3.2 ± 2.5 maxillary and 2.1 ± 2.6 mandibular permanent teeth (min-max, 0-14). Patients received a mean of 8.2 ± 3.8 implants (1-20). Most implants were placed in the third decade of life, 24.6% of the implants were placed in children (0-17 years of age). 1391 implants had information on follow-up (72 failures, 5.2%). The 20-year CSR was 84.6%. The probability of failure was 4.5% (95%CI 3.5%-5.6%, p < 0.001). Additional treatments performed were Le Fort I (99 implants, 20 patients, 3.5% failed), grafting (497 implants, 77 patients, 5.2% failed), distraction osteogenesis (79 implants, 16 patients, 10.1% failed). Mean follow-up was 42.9 ± 41.9 months (min-max, 2-240). Dental implants placed in ED patients, either infants or adults, present a high survival rate (20-year CSR 84.6%). Copyright © 2018 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  2. Biomedical engineering principles of modern cochlear implants and recent surgical innovations.

    Science.gov (United States)

    Eshraghi, Adrien A; Gupta, Chhavi; Ozdamar, Ozcan; Balkany, Thomas J; Truy, Eric; Nazarian, Ronen

    2012-11-01

    This review covers the most recent clinical and surgical advances made in the development and application of cochlear implants (CIs). In recent years, dramatic progress has been made in both clinical and basic science aspect of cochlear implantation. Today's modern CI uses multi-channel electrodes with highly miniaturized powerful digital processing chips. This review article describes the function of various components of the modern multi-channel CIs. A selection of the most recent clinical and surgical innovations is presented. This includes the preliminary results with electro-acoustic stimulation or hybrid devices and ongoing basic science research that is focused on the preservation of residual hearing post-implantation. The result of an original device that uses a binaural stimulation mode with a single implanted receiver/stimulator is also presented. The benefit and surgical design of a temporalis pocket technique for the implant's receiver stimulator is discussed. Advances in biomedical engineering and surgical innovations that lead to an increasingly favorable clinical outcome and to an expansion of the indication of CI surgery are presented and discussed. Copyright © 2012 Wiley Periodicals, Inc.

  3. Subjective consequences of permanent pacemaker therapy in patients under the age of retirement

    DEFF Research Database (Denmark)

    Mickley, H; Petersen, J; Nielsen, B L

    1989-01-01

    During a 5-year period, 81 patients ages 20 to 60 years old had implantation of a permanent cardiac pacemaker at the University Hospital, Odense. At follow-up, during 1985, the 73 survivors received a semi-structured questionnaire regarding subjective consequences of pacemaker therapy, and 72...... people (98.6%) agreed to participate. The mean pacing period (range) was 33.8 (11-72) months. Surgical intervention was required in 14 patients (19.4%) during follow-up. Regarding all symptoms 67 patients (93.1%) perceived benefit from the pacemaker. The effectiveness of cardiac pacing was most...... or a sensation of "impulses"/palpitations. To the majority (49 patients or 68.1%) pacemaker treatment did not influence quality of sexual activity. Six patients (8.3%) perceived an improvement, whereas a corresponding number felt deterioration in sexual activity following pacemaker implantation. Pacemaker...

  4. Comparison of biochemical failure definitions for permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Kuban, Deborah A.; Levy, Larry B.; Potters, Louis; Beyer, David C.; Blasko, John C.; Moran, Brian J.; Ciezki, Jay P.; Zietman, Anthony L.; Zelefsky, Michael J.; Pisansky, Thomas M.; Elshaikh, Mohamed; Horwitz, Eric M.

    2006-01-01

    Purpose: To assess prostate-specific antigen (PSA) failure definitions for patients with Stage T1-T2 prostate cancer treated by permanent prostate brachytherapy. Methods and Materials: A total of 2,693 patients treated with radioisotopic implant as solitary treatment for T1-T2 prostatic adenocarcinoma were studied. All patients had a pretreatment PSA, were treated at least 5 years before analysis, 1988 to 1998, and did not receive hormonal therapy before recurrence. Multiple PSA failure definitions were tested for their ability to predict clinical failure. Results: Definitions which determined failure by a certain increment of PSA rise above the lowest PSA level to date (nadir + x ng/mL) were more sensitive and specific than failure definitions based on PSA doubling time or a certain number of PSA rises. The sensitivity and specificity for the nadir + 2 definition were 72% and 83%, vs. 51% and 81% for 3 PSA rises. The surgical type definitions (PSA exceeding an absolute value) could match this sensitivity and specificity but only when failure was defined as exceeding a PSA level in the 1-3 ng/mL range and only when patients were allowed adequate time to nadir. When failure definitions were compared by time varying covariate regression analysis, nadir + 2 ng/mL retained the best fit. Conclusions: For patients treated by permanent radioisotopic implant for prostate cancer, the definition nadir + 2 ng/mL provides the best surrogate for failure throughout the entire follow-up period, similar to patients treated by external beam radiotherapy. Therefore, the same PSA failure definition could be used for both modalities. For brachytherapy patients with long-term follow-up, at least 6 years, defining failure as exceeding an absolute PSA level in the 0.5 ng/mL range may be reasonable

  5. Simultaneous bilateral stereotactic procedure for deep brain stimulation implants: a significant step for reducing operation time.

    Science.gov (United States)

    Fonoff, Erich Talamoni; Azevedo, Angelo; Angelos, Jairo Silva Dos; Martinez, Raquel Chacon Ruiz; Navarro, Jessie; Reis, Paul Rodrigo; Sepulveda, Miguel Ernesto San Martin; Cury, Rubens Gisbert; Ghilardi, Maria Gabriela Dos Santos; Teixeira, Manoel Jacobsen; Lopez, William Omar Contreras

    2016-07-01

    OBJECT Currently, bilateral procedures involve 2 sequential implants in each of the hemispheres. The present report demonstrates the feasibility of simultaneous bilateral procedures during the implantation of deep brain stimulation (DBS) leads. METHODS Fifty-seven patients with movement disorders underwent bilateral DBS implantation in the same study period. The authors compared the time required for the surgical implantation of deep brain electrodes in 2 randomly assigned groups. One group of 28 patients underwent traditional sequential electrode implantation, and the other 29 patients underwent simultaneous bilateral implantation. Clinical outcomes of the patients with Parkinson's disease (PD) who had undergone DBS implantation of the subthalamic nucleus using either of the 2 techniques were compared. RESULTS Overall, a reduction of 38.51% in total operating time for the simultaneous bilateral group (136.4 ± 20.93 minutes) as compared with that for the traditional consecutive approach (220.3 ± 27.58 minutes) was observed. Regarding clinical outcomes in the PD patients who underwent subthalamic nucleus DBS implantation, comparing the preoperative off-medication condition with the off-medication/on-stimulation condition 1 year after the surgery in both procedure groups, there was a mean 47.8% ± 9.5% improvement in the Unified Parkinson's Disease Rating Scale Part III (UPDRS-III) score in the simultaneous group, while the sequential group experienced 47.5% ± 15.8% improvement (p = 0.96). Moreover, a marked reduction in the levodopa-equivalent dose from preoperatively to postoperatively was similar in these 2 groups. The simultaneous bilateral procedure presented major advantages over the traditional sequential approach, with a shorter total operating time. CONCLUSIONS A simultaneous stereotactic approach significantly reduces the operation time in bilateral DBS procedures, resulting in decreased microrecording time, contributing to the optimization of functional

  6. Permanent Pacemaker-Induced Superior Vena Cava Syndrome: Successful Treatment by Endovascular Stent

    International Nuclear Information System (INIS)

    Lanciego, Carlos; Rodriguez, Mario; Rodriguez, Adela; Carbonell, Miguel A.; Garcia, Lorenzo Garcia

    2003-01-01

    The use of metallic stents in the management of benign and malignant superior vena cava syndrome (SVCS) is well documented. Symptomatic stenosis or occlusion of the SVC is a rare complication of a transvenous permanent pacemaker implant. Suggested treatments have included anticoagulation therapy, thrombolysis, balloon angioplasty and surgery. More recently, endovascular stenting has evolved as an attractive alternative but the data available in the literature are limited. We describe a case in which venous stenting with a Wallstent endoprosthesis was used successfully. The patient remains symptom free and with normal pacemaker function 36 months later

  7. Current steering and current focusing in cochlear implants: comparison of monopolar, tripolar, and virtual channel electrode configurations.

    Science.gov (United States)

    Berenstein, Carlo K; Mens, Lucas H M; Mulder, Jef J S; Vanpoucke, Filiep J

    2008-04-01

    To compare the effects of Monopole (Mono), Tripole (Tri), and "Virtual channel" (Vchan) electrode configurations on spectral resolution and speech perception in a crossover design. Nine experienced adults who received an Advanced Bionics CII/90K cochlear implant participated in a crossover design using three experimental strategies for 2 wk each. Three strategies were compared: (1) Mono; (2) Tri with current partly returning to adjacent electrodes and partly (25 or 75%) to the extracochlear reference; and (3) a monopolar "Vchan" strategy creating seven intermediate channels between two contacts. Each strategy was a variant of the standard "HiRes" processing strategy using 14 channels and 1105 pulses/sec/ channel, and a pulse duration of 32 microsec/phase. Spectral resolution was measured using broadband noise with a sinusoidally rippled spectral envelope with peaks evenly spaced on a logarithmic frequency scale. Speech perception was measured for monosyllables in quiet and in steady-state and fluctuating noises. Subjective comments on music experience and preferences in everyday use were assessed through questionnaires. Thresholds and most comfortable levels with Mono and Vchan were both significantly lower than levels with Tri. Spectral resolution was significantly higher with Tri than with Mono; spectral resolution with Vchan did not differ significantly from the other configurations. Moderate but significant correlations between word recognition and spectral resolution were found in speech in quiet and fluctuating noise. For speech in quiet, word recognition was best with Mono and worst with Vchan; Tri did not significantly differ from the other configurations. Pooled across the noise conditions, word recognition was best with Tri and worst with Vchan (Mono did not significantly differ from the other configurations). These differences were small and insufficient to result in a clear increase in performance across subjects if the result from the best

  8. Hearing Preservation after Cochlear Implantation: UNICAMP Outcomes

    Directory of Open Access Journals (Sweden)

    Guilherme Machado de Carvalho

    2013-01-01

    Full Text Available Background. Electric-acoustic stimulation (EAS is an excellent choice for people with residual hearing in low frequencies but not high frequencies and who derive insufficient benefit from hearing aids. For EAS to be effective, subjects' residual hearing must be preserved during cochlear implant (CI surgery. Methods. We implanted 6 subjects with a CI. We used a special surgical technique and an electrode designed to be atraumatic. Subjects' rates of residual hearing preservation were measured 3 times postoperatively, lastly after at least a year of implant experience. Subjects' aided speech perception was tested pre- and postoperatively with a sentence test in quiet. Subjects' subjective responses assessed after a year of EAS or CI experience. Results. 4 subjects had total or partial residual hearing preservation; 2 subjects had total residual hearing loss. All subjects' hearing and speech perception benefited from cochlear implantation. CI diminished or eliminated tinnitus in all 4 subjects who had it preoperatively. 5 subjects reported great satisfaction with their new device. Conclusions. When we have more experience with our surgical technique we are confident we will be able to report increased rates of residual hearing preservation. Hopefully, our study will raise the profile of EAS in Brazil and Latin/South America.

  9. In vitro modifications of the scala tympani environment and the cochlear implant array surface.

    Science.gov (United States)

    Kontorinis, Georgios; Scheper, Verena; Wissel, Kirsten; Stöver, Timo; Lenarz, Thomas; Paasche, Gerrit

    2012-09-01

    To investigate the influence of alterations of the scala tympani environment and modifications of the surface of cochlear implant electrode arrays on insertion forces in vitro. Research experimental study. Fibroblasts producing neurotrophic factors were cultivated on the surface of Nucleus 24 Contour Advance electrodes. Forces were recorded by an Instron 5542 Force Measurement System as three modified arrays were inserted into an artificial scala tympani model filled with phosphate-buffered saline (PBS). The recorded forces were compared to control groups including three unmodified electrodes inserted into a model filled with PBS (unmodified environment) or Healon (current practice). Fluorescence microscopy was used before and after the insertions to identify any remaining fibroblasts. Additionally, three Contour Advance electrodes were inserted into an artificial model, filled with alginate/barium chloride solution at different concentrations, while insertion forces were recorded. Modification of the scala tympani environment with 50% to 75% alginate gel resulted in a significant decrease in the insertion forces. The fibroblast-coated arrays also led to decreased forces comparable to those recorded with Healon. Fluorescence microscopy revealed fully cell-covered arrays before and partially covered arrays after the insertion; the fibroblasts on the arrays' modiolar surface remained intact. Modifications of the scala tympani's environment with 50% to 75% alginate/barium chloride and of the cochlear implant electrode surface with neurotrophic factor-producing fibroblasts drastically reduce the insertion forces. As both modifications may serve future intracochlear therapies, it is expected that these might additionally reduce possible insertion trauma. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  10. The effect of the radial function on I-125 seeds used for permanent prostate implantation

    International Nuclear Information System (INIS)

    Pickett, Barby; Pouliot, Jean

    2004-01-01

    The purpose of this study was to evaluate the integrity of eight commercially-available low-activity Iodine-125 ( 125 I) seeds for their radial function g(r) and its effect on the dose delivered to the adjacent critical structures when used in permanent prostate implants (PPI). Ten previously treated patients were retrospectively used in this comparison. The Amersham Health Oncura seed was used to peripherally design an isodose distribution with urethral and anterior rectal wall sparing. Plan criteria included minimum coverage of 144 Gy to the planning target volume (PTV), ≤ 70% dose to 150% of the PTV volume (V150-PTV), and the quantity of needles ≤ 70% of the size of the PTV, in cc. Upon completion of the Oncura plan, the seed type was changed and the activity was adjusted until the V100-PTV for each of the other 7 seed types matched the V100-PTV defined by the Oncura seed. Computed tomography (CT)-based postimplant dosimetry was used to determine the dose to 40% (D40) of the bulb of the penis (in Gy). Dose-volume histograms (DVH) were used to evaluate the differences to V100 (in %) and D40 (in Gy) of the anterior rectal wall and bulb of the penis, and V100 (in %) of the urethra. The data was tabulated. Radioactive 125 I sources included in this study were 125 I Source 2301 (Best); I-Plant (MedTech), IoGold (Mentor), Oncura (Amersham Health), ProstaSeed (UroCor), SelectSeed (Nucletron), SourceTech (Bard), and Symmetra (UroMed). The sizes of the PTV for the 10 patients ranged from 18.82 cc to 48.99 cc. The Oncura seed was used as the reference seed and all other seed types were normalized to it for data comparison. It was determined that the dose rate constant (xwedge) and anisotropy factor (phi) contribute to the activity needed to achieve comparable V100-PTV doses, but a strong dependence on the radial function g(r) was found to effect the doses to the critical structures studied. Values of g(r) at 4 cm were calculated and the IoGold and SourceTech seeds

  11. Tinnitus after Simultaneous and Sequential Bilateral Cochlear Implantation

    Directory of Open Access Journals (Sweden)

    Geerte G. J. Ramakers

    2017-11-01

    , four patients had an additional benefit of the second CI: a total suppression of tinnitus compared with their unilateral situation.ConclusionWhile bilateral cochlear implantation can have a positive effect on preoperative tinnitus complaints, the induction of (temporary or permanent tinnitus was also reported.Clinical Trial RegistrationDutch Trial Register NTR1722.

  12. DBS Electrodes With Single Disconnected Contacts: Long-Term Observation and Implications for the Management.

    Science.gov (United States)

    Allert, Niels; Jusciute, Egle; Quindt, Regina; Lindlau, Alexandra; Nolden, Brit Meike; Daryaeitabar, Mohammadreza; Karbe, Hans

    2018-04-27

    To evaluate the long-term course of quadripolar DBS electrodes with disconnected single contacts that cannot be used for DBS. Quadripolar electrodes with open circuits of single contacts or monopolar impedances >6500 Ω were identified from a cohort of 2082 electrodes from 1044 patients with variable movement disorders. The long-term course was analyzed from follow-up data. Disconnected contacts were found in 58 electrodes (2.8%) from 49 patients (4.7%). The dysfunction was restricted to one contact in 51 electrodes (87.9%), two contacts in 5 electrodes (8.6%), three contacts in 2 electrodes (3.4%). Onset was related to surgery (implantation, impulse generator replacement, or other surgical revision) in 34 electrodes (58.6%), trauma in 2 electrodes, undetermined in 11 electrodes, and occurred spontaneously after previous normal measurements in 11 electrodes (19.0%). Repeated measurements at follow-ups of ≥3 months were available in 39 electrodes. In 16 electrodes (41.0%) abnormal impedances persisted constantly during observations up to 11½ years (47 ± 35 months, median 41 months). In 21 electrodes (53.8%) abnormal impedances remained restricted to the initial contact(s) but varied considerably between measurements during up to six years (39 ± 18 months, median 38 months). Only two electrodes (5.1%) with initially one disconnected contact developed a disconnection of a second contact. Disconnections of single contacts occur with increasing cumulative incidence during long-term DBS. Surgery is the main causative risk factor. In the majority of electrodes, the dysfunction remains restricted to the initial contact(s). © 2018 International Neuromodulation Society.

  13. High-Density Stretchable Electrode Grids for Chronic Neural Recording.

    Science.gov (United States)

    Tybrandt, Klas; Khodagholy, Dion; Dielacher, Bernd; Stauffer, Flurin; Renz, Aline F; Buzsáki, György; Vörös, János

    2018-04-01

    Electrical interfacing with neural tissue is key to advancing diagnosis and therapies for neurological disorders, as well as providing detailed information about neural signals. A challenge for creating long-term stable interfaces between electronics and neural tissue is the huge mechanical mismatch between the systems. So far, materials and fabrication processes have restricted the development of soft electrode grids able to combine high performance, long-term stability, and high electrode density, aspects all essential for neural interfacing. Here, this challenge is addressed by developing a soft, high-density, stretchable electrode grid based on an inert, high-performance composite material comprising gold-coated titanium dioxide nanowires embedded in a silicone matrix. The developed grid can resolve high spatiotemporal neural signals from the surface of the cortex in freely moving rats with stable neural recording quality and preserved electrode signal coherence during 3 months of implantation. Due to its flexible and stretchable nature, it is possible to minimize the size of the craniotomy required for placement, further reducing the level of invasiveness. The material and device technology presented herein have potential for a wide range of emerging biomedical applications. © 2018 The Authors. Published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Iodine-125 thin seeds decrease prostate swelling during transperineal interstitial permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Beydoun, Nadine; Bucci, Joseph A.; Chin, Yaw S.; Malouf, David

    2014-01-01

    Prostate swelling following seed implantation is a well-recognised phenomenon. The purpose of this intervention was to assess whether using thinner seeds reduces post-implant swelling with permanent prostate brachytherapy. Eighteen consecutive patients eligible for prostate seed brachytherapy underwent seed implantation using iodine-125 (I-125) thin seeds. Operative time, dosimetry, prostate swelling and toxicity were assessed and compared with standard I-125 stranded seed controls, sourced from the department's brachytherapy database. A learning curve was noted with the thin seeds in terms of greater bending and deviation of needles from their intended path. This translated into significantly longer total operative time (88 vs 103 minutes; P=0.009, 95% confidence interval (CI) 4.1-24.3) and time per needle insertion (2.6 vs 3.7 minutes; P<0.001, 95% CI 0.5-1.3) for the thin seeds. Day 30 prostate volumes were significantly smaller in the thin seed group compared with standard seeds (40.9cc vs 46.8cc; P=0.001, 95% CI 1.5-5.6). The ratio of preoperative transrectal ultrasound to day 30 post-implant CT volume was also smaller in the thin seed group (1.2±0.1 for standard seeds vs 1.1±0.1 for thin seeds). Post-implant dosimetric parameters were comparable for both groups. No significant differences were seen in acute urinary morbidity or quality of life between the two groups. I-125 thin seeds are associated with an initial learning curve, with longer operative time, even for experienced brachytherapists. The significant reduction in day 30 prostate volumes with the thin seeds has useful implications in terms of optimising dose coverage to the prostate in the early period post-implantation, as well as improving the accuracy of post-implant dosimetric assessments.

  15. Intraoperative dynamic dosimetry for prostate implants

    Energy Technology Data Exchange (ETDEWEB)

    Todor, D A [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY 10021 (United States); Zaider, M [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY 10021 (United States); Cohen, G N [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY 10021 (United States); Worman, M F [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY 10021 (United States); Zelefsky, M J [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY 10021 (United States)

    2003-05-07

    This paper describes analytic tools in support of a paradigm shift in brachytherapy treatment planning for prostate cancer - a shift from standard pre-planning to intraoperative planning using dosimetric feedback based on the actual deposited seed positions within the prostate. The method proposed is guided by several desiderata: (a) bringing both planning and evaluation in the operating room (i.e. make post-implant evaluation superfluous) therefore making rectifications - if necessary - still achievable; (b) making planning and implant evaluation consistent by using the same imaging system (ultrasound); and (c) using only equipment commonly found in a hospital operating room. The intraoperative dosimetric evaluation is based on the fusion between ultrasound images and 3D seed coordinates reconstructed from fluoroscopic projections. Automatic seed detection and registration of the fluoroscopic and ultrasound information, two of the three key ingredients needed for the intraoperative dynamic dosimetry optimization (IDDO), are explained in detail. The third one, the reconstruction of 3D coordinates from projections, was reported in a previous article. The algorithms were validated using a custom-designed phantom with non-radioactive (dummy) seeds. Also, fluoroscopic images were taken at the conclusion of an actual permanent prostate implant and compared with data on the same patient obtained from radiographic-based post-implant evaluation. To offset the effect of organ motion the comparison was performed in terms of the proximity function of the two seed distributions. The agreement between the intra- and post-operative seed distributions was excellent.

  16. Toxicity evaluation of PEDOT/biomolecular composites intended for neural communication electrodes

    International Nuclear Information System (INIS)

    Asplund, M; Thaning, E; Von Holst, H; Lundberg, J; Sandberg-Nordqvist, A C; Kostyszyn, B; Inganaes, O

    2009-01-01

    Electrodes coated with the conducting polymer poly(3,4-ethylene dioxythiophene) (PEDOT) possess attractive electrochemical properties for stimulation or recording in the nervous system. Biomolecules, added as counter ions in electropolymerization, could further improve the biomaterial properties, eliminating the need for surfactant counter ions in the process. Such PEDOT/biomolecular composites, using heparin or hyaluronic acid, have previously been investigated electrochemically. In the present study, their biocompatibility is evaluated. An agarose overlay assay using L929 fibroblasts, and elution and direct contact tests on human neuroblastoma SH-SY5Y cells are applied to investigate cytotoxicity in vitro. PEDOT:heparin was further evaluated in vivo through polymer-coated implants in rodent cortex. No cytotoxic response was seen to any of the PEDOT materials tested. The examination of cortical tissue exposed to polymer-coated implants showed extensive glial scarring irrespective of implant material (Pt:polymer or Pt). However, quantification of immunological response, through distance measurements from implant site to closest neuron and counting of ED1+ cell density around implant, was comparable to those of platinum controls. These results indicate that PEDOT:heparin surfaces were non-cytotoxic and show no marked difference in immunological response in cortical tissue compared to pure platinum controls.

  17. Evoked EMG-based torque prediction under muscle fatigue in implanted neural stimulation

    Science.gov (United States)

    Hayashibe, Mitsuhiro; Zhang, Qin; Guiraud, David; Fattal, Charles

    2011-10-01

    In patients with complete spinal cord injury, fatigue occurs rapidly and there is no proprioceptive feedback regarding the current muscle condition. Therefore, it is essential to monitor the muscle state and assess the expected muscle response to improve the current FES system toward adaptive force/torque control in the presence of muscle fatigue. Our team implanted neural and epimysial electrodes in a complete paraplegic patient in 1999. We carried out a case study, in the specific case of implanted stimulation, in order to verify the corresponding torque prediction based on stimulus evoked EMG (eEMG) when muscle fatigue is occurring during electrical stimulation. Indeed, in implanted stimulation, the relationship between stimulation parameters and output torques is more stable than external stimulation in which the electrode location strongly affects the quality of the recruitment. Thus, the assumption that changes in the stimulation-torque relationship would be mainly due to muscle fatigue can be made reasonably. The eEMG was proved to be correlated to the generated torque during the continuous stimulation while the frequency of eEMG also decreased during fatigue. The median frequency showed a similar variation trend to the mean absolute value of eEMG. Torque prediction during fatigue-inducing tests was performed based on eEMG in model cross-validation where the model was identified using recruitment test data. The torque prediction, apart from the potentiation period, showed acceptable tracking performances that would enable us to perform adaptive closed-loop control through implanted neural stimulation in the future.

  18. A combination of permanent magnet and magnetic coil for a large diameter ion source

    International Nuclear Information System (INIS)

    Uramoto, Joshin; Kubota, Yusuke; Miyahara, Akira.

    1980-02-01

    A large diameter ion source for fast neutral beam injection is designed under a magnetic field (we call ''Uramoto Field'') composed of a circular ferrite permanent magnet and a usual coreless magnetic coil. As the magnetic filed is reduced abruptly in a discharge anode, an ion source with a uniform ion current density over a large diameter is produced easily without a ''button'' of ORNL duoPIGatron type ion source (a floating electrode to diffuse an axial plasma flow radially). (author)

  19. [Meta-analysis of the efficacy of cochlear implantation in deaf patients with inner ear malformation].

    Science.gov (United States)

    Xu, Qingqing; Zhai, Suoqiang; Han, Dongyi; Yang, Shiming; Shen, Weidong

    2014-04-01

    Assess and compare the clinical efficacy and safety of cochlear implantation in deaf patients with inner ear malformation and in the ones with normal inner ear structure, so that to clarify whether it is effective to restore hearing for the deaf patients with inner ear malformation. The literature with relevant key words were retrieved in the databases including PubMed, YZ365. com, WANFANG data, CMJD, CHKD and CNKI with language limited to Chinese and English. Extracted data included author, year of publication, diagnosis, treatment, et al. The clinical efficacy of cochlear implantation was assessed by the complications, electrode impedance, behavior T-level, hearing abilities and speech discrimination. Meta-analysis was performed using random or fixed effects model according to the heterogeneity of data. There were 11 randomized control studies involving 655 patients included in this study. There was no statistically significant difference among the deaf patients in mixed inner ear-malformation group, Mondini group and large vestibular aqueduct syndrome group in the aspects of postoperative complications, electrode impedance, behavior T-level, hearing abilities and speech discrimination. Cochlear implantation could be the way of treatment and rehabilitation for deaf patients with inner ear malformation. Further controlled studies with longer follow-up periods and more multiracial cases included may help to evaluate the efficacy of cochlear implantation for deaf patients with inner ear malformation more reliably.

  20. Evaluation and use of regenerative multi electrode interfaces in peripheral nerves

    Science.gov (United States)

    Desai, Vidhi

    Peripheral nerves offer unique accessibility to the innate motor and sensory pathways that can be interfaced with high degree of selectivity for intuitive and bidirectional control of advanced upper extremity prosthetic limbs. Several peripheral nerve interfaces have been proposed and investigated over the last few decades with significant progress made in the area of sensory feedback. However, clinical translation still remains a formidable challenge due to the lack of long term recordings. Prominent causes include signal degradation, eventual interface failures, and lack of specificity in the low amplitude nerve signals. This dissertation evaluates the capabilities of the newly developed Regenerative Multi-electrode Interface (REMI) by the characterization of signal quality progression, the identification of interfaced axon types, and the demonstration of "functional linkage" between acquired signals and target organs. Chapter 2 details the chronic recording of high quality signals from REMI in sciatic nerve which remained stable over a 120 day implantation period indicative of minimal ongoing tissue response with no detrimental effects on the recording ability. The dominant cause of failures was attributable to abiotic factors pertaining to the connector/wire breakage, observed in 76% of REMI implants. Also, the REMI implants had 20% higher success rate and significantly larger Signal to Noise Ratio (SNR) in comparison to the Utah Slanted Electrode Array (USEA). Chapter 3 describes the successful feasibility of interfacing with motor and sensory axons by REMI implantation in the tibial and sural fascicles of the sciatic nerve. A characteristic sampling bias towards recording signals from medium-to-large diameter axons that are primarily involved in mechanoception and proprioception sensory functions was uncovered. Specific bursting units (Inter Spike Interval of 30-70ms) were observed most frequently from the tibial fascicle during bipedal locomotion. Chapter 4