WorldWideScience

Sample records for permanent testing laboratory

  1. Two cylinder permanent magnet stirrer for liquid metals

    Science.gov (United States)

    Bojarevičs, A.; Baranovskis, R.; Kaldre, I.; Milgrāvis, M.; Beinerts, T.

    2017-07-01

    To achieve a uniform liquid metal composition and temperature distribution, stirring is often necessary for industrial processes. Here, a novel permanent magnet system for liquid melt stirring is proposed. It promises very low energy consumption and options for multiple different flow types compared to traditional travelling magnetic field inductors or mechanical stirrers. The proposed system has a simple design: it consists of two rotating permanent magnet cylinders, which are magnetized transversely to the axis of the cylinders. The experimental device was developed and tested under various regimes using GaInSn alloy in a cylindrical crucible. Aluminum stirring by permanent magnets in laboratory scale is tested, and stirring impact on directional solidification of metallic alloys is experimentally investigated.

  2. Permanent deformation testing for a new South African mechanistic pavement design method

    CSIR Research Space (South Africa)

    Anochie-Boateng, Joseph

    2012-01-01

    Full Text Available is to develop test protocols for hot-mix asphalt materials. To date, no permanent deformation test is incorporated into South African pavement design guides. The objective of this paper is to present the development process of a repeated load axial permanent...

  3. Design and Demonstration of a Test-Rig for Static Performance-Studies of Permanent Magnet Couplings

    DEFF Research Database (Denmark)

    Högberg, Stig; Jensen, Bogi Bech; Bendixen, Flemming Buus

    2013-01-01

    The design and construction of an easy-to-use test-rig for permanent magnet couplings is presented. Static torque of permanent magnet couplings as a function of angular displacement is measured of permanent magnet couplings through an semi-automated test system. The test-rig is capable of measuring...

  4. Object permanence tests on gibbons (Hylobatidae).

    Science.gov (United States)

    Fedor, Anna; Skollár, Gabriella; Szerencsy, Nóra; Ujhelyi, Mária

    2008-11-01

    Ten gibbons of various species (Symphalangus syndactylus, Hylobates lar, Nomascus gabriellae, and Nomascus leucogenys) were tested on object permanence tasks. Three identical wooden boxes, presented in a linear line, were used to hide pieces of food. The authors conducted single visible, single invisible, double invisible, and control displacements, in both random and nonrandom order. During invisible displacements, the experimenter hid the object in her hand before putting it into a box. The performance of gibbons was better than expected by chance in all the tests, except for the randomly ordered double displacement. However, individual analysis of performance showed great variability across subjects, and only 1 gibbon is assumed to have solved single visible and single invisible displacements without recourse to a strategy that the control test eliminated. (PsycINFO Database Record (c) 2008 APA, all rights reserved).

  5. The permanence of mental objects: testing magical thinking on perceived and imaginary realities.

    Science.gov (United States)

    Subbotsky, Eugene

    2005-03-01

    This study tested participants' preparedness to acknowledge that an object could change as a result of magical intervention. Six- and 9-year-old children and adults treated perceived and imagined objects as being equally permanent. Adults treated a fantastic object as significantly less permanent than either perceived or imagined objects. Results were similar when a different type of mental-physical causality--a participant's own wish--was examined. Adults were also tested on the permanence of personally significant imagined objects (participants' images of their future lives). Although almost all participants claimed that they did not believe in magic, in test trials they were not prepared to rule out the possibility that their future lives could be affected by a magical curse. Copyright 2005 APA, all rights reserved.

  6. Laboratory Tests

    Science.gov (United States)

    ... Medical Devices Radiation-Emitting Products Vaccines, Blood & Biologics Animal & ... What are lab tests? Laboratory tests are medical devices that are intended for use on samples of blood, urine, or other tissues ...

  7. [Laboratory accreditation and proficiency testing].

    Science.gov (United States)

    Kuwa, Katsuhiko

    2003-05-01

    ISO/TC 212 covering clinical laboratory testing and in vitro diagnostic test systems will issue the international standard for medical laboratory quality and competence requirements, ISO 15189. This standard is based on the ISO/IEC 17025, general requirements for competence of testing and calibration laboratories and ISO 9001, quality management systems-requirements. Clinical laboratory services are essential to patient care and therefore should be available to meet the needs of all patients and clinical personnel responsible for human health care. If a laboratory seeks accreditation, it should select an accreditation body that operates according to this international standard and in a manner which takes into account the particular requirements of clinical laboratories. Proficiency testing should be available to evaluate the calibration laboratories and reference measurement laboratories in clinical medicine. Reference measurement procedures should be of precise and the analytical principle of measurement applied should ensure reliability. We should be prepared to establish a quality management system and proficiency testing in clinical laboratories.

  8. FOOD SAFETY TESTING LABORATORY

    Data.gov (United States)

    Federal Laboratory Consortium — This laboratory develops screening assays, tests and modifies biosensor equipment, and optimizes food safety testing protocols for the military and civilian sector...

  9. Effects of Selected Object Characteristics on Object Permanence Test Performance.

    Science.gov (United States)

    Lingle, Kathleen M.; Lingle, John H.

    A study was conducted to investigate the degree to which both object familiarity and motivational factors influence infants' search behavior in an object permanence test. Infants' search behavior for an unfamiliar test object was compared with search behavior for (a) an experientially familiar object that each infant had played with daily for a…

  10. Hanford Permanent Isolation Barrier Program: Asphalt technology test plan

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, H.D.; Romine, R.A.

    1994-05-01

    The Hanford Permanent Isolation Barriers use engineered layers of natural materials to create an integrated structure with backup protective features. The objective of current designs is to develop a maintenance-free permanent barrier that isolates wastes for a minimum of 1000 years by limiting water drainage to near-zero amounts. Asphalt is being used as an impermeable water diversion layer to provide a redundant layer within the overall barrier design. Data on asphalt barrier properties in a buried environment are not available for the required 100-year time frame. The purpose of this test plan is to outline the activities planned to obtain data with which to estimate performance of the asphalt layers.

  11. Hanford Permanent Isolation Barrier Program: Asphalt technology test plan

    International Nuclear Information System (INIS)

    Freeman, H.D.; Romine, R.A.

    1994-05-01

    The Hanford Permanent Isolation Barriers use engineered layers of natural materials to create an integrated structure with backup protective features. The objective of current designs is to develop a maintenance-free permanent barrier that isolates wastes for a minimum of 1000 years by limiting water drainage to near-zero amounts. Asphalt is being used as an impermeable water diversion layer to provide a redundant layer within the overall barrier design. Data on asphalt barrier properties in a buried environment are not available for the required 100-year time frame. The purpose of this test plan is to outline the activities planned to obtain data with which to estimate performance of the asphalt layers

  12. The Permanence of Mental Objects: Testing Magical Thinking on Perceived and Imaginary Realities

    Science.gov (United States)

    Subbotsky, Eugene

    2005-01-01

    This study tested participants' preparedness to acknowledge that an object could change as a result of magical intervention. Six- and 9-year-old children and adults treated perceived and imagined objects as being equally permanent. Adults treated a fantastic object as significantly less permanent than either perceived or imagined objects. Results…

  13. Laboratory testing in hyperthyroidism.

    Science.gov (United States)

    Grebe, Stefan K G; Kahaly, George J

    2012-09-01

    The clinical diagnosis of hypo- or hyperthyroidism is difficult (full text available online: http://education.amjmed.com/pp1/272). Clinical symptoms and signs are often non-specific, and there is incomplete correlation between structural and functional thyroid gland changes. Laboratory testing is therefore indispensible in establishing the diagnosis of thyrotoxicosis. Similar considerations apply to treatment monitoring. Laboratory testing also plays a crucial role in establishing the most likely cause for a patient's hyperthyroidism. Finally, during pregnancy, when isotopic scanning is relatively contraindicated and ultrasound is more difficult to interpret, laboratory testing becomes even more important. Copyright © 2012. Published by Elsevier Inc.

  14. The Cost-Effective Laboratory: Implementation of Economic Evaluation of Laboratory Testing

    Directory of Open Access Journals (Sweden)

    Bogavac-Stanojevic Natasa

    2017-09-01

    Full Text Available Laboratory testing as a part of laboratory in vitro diagnostic (IVD has become required tool in clinical practice for diagnosing, monitoring and prognosis of diseases, as well as for prediction of treatment response. The number of IVD tests available in laboratory practice has increased over the past decades and is likely to further increase in the future. Consequently, there is growing concern about the overutilization of laboratory tests and rising costs for laboratory testing. It is estimated that IVD accounts for between 1.4 and 2.3% of total healthcare expenditure and less than 5% of total hospital cost (Lewin Group report. These costs are rather low when compared to pharmaceuticals and medical aids which account for 15 and 5%, respectively. On the other hand, IVD tests play an important role in clinical practice, as they influence from 60% to 70% of clinical decision-making. Unfortunately, constant increases in healthcare spending are not directly related to healthcare benefit. Since healthcare resources are limited, health payers are interested whether the benefits of IVD tests are actually worth their cost. Many articles have introduced frameworks to assess the economic value of IVD tests. The most appropriate tool for quantitative assessment of their economic value is cost-effectiveness (CEA and cost-utility (CUA analysis. The both analysis determine cost in terms of effectiveness or utilities (combine quantity and quality of life of new laboratory test against its alternative. On the other hand, some investigators recommended calculation of laboratory test value as product of two ratios: Laboratory test value = (Technical accuracy/Turnaround time × (Utility/Costs. Recently, some researches used multicriteria decision analysis which allows comparison of diagnostic strategies in terms of benefits, opportunities, costs and risks. All analyses are constructed to identify laboratory test that produce the greatest healthcare benefit with

  15. Understanding Laboratory Tests

    Science.gov (United States)

    ... and Drug Administration (FDA) regulates the development and marketing of all laboratory tests that use test kits ... Cancer.gov en español Multimedia Publications Site Map Digital Standards for NCI Websites POLICIES Accessibility Comment Policy ...

  16. Metallurgical Laboratory and Components Testing

    Data.gov (United States)

    Federal Laboratory Consortium — In the field of metallurgy, TTC is equipped to run laboratory tests on track and rolling stock components and materials. The testing lab contains scanning-electron,...

  17. Evaluation of Permanent Deformation of Unmodified and Rubber-Reinforced SMA Asphalt Mixtures Using Dynamic Creep Test

    Directory of Open Access Journals (Sweden)

    Herda Yati Katman

    2015-01-01

    Full Text Available This paper presents the evaluation of permanent deformation of rubber-reinforced SMA asphalt mixtures by using dynamic creep test. The effect of trans-polyoctenamer as a cross-linking agent in permanent deformation of rubberized mixtures was also evaluated. Dynamic creep test was conducted at different stress levels (200 kPa, 400 kPa and temperatures (40°C, 50°C. Permanent deformation parameters such as dynamic creep curve, ultimate strain, and creep strain slope (CSS were used to analyse the results. Finally, the creep behaviour of the specimens was estimated by the Zhou three-stage creep model. The results show that crumb rubber and trans-polyoctenamer significantly affected the parameters especially at high stress and temperatures. Consistent findings were observed for all permanent deformation parameters. Moreover, based on Zhou model, it was concluded that resistance to permanent deformation was improved by application of crumb rubber and trans-polyoctenamer.

  18. The Question of Decalage Between Object Permanence and Person Permanence

    Science.gov (United States)

    And Others; Jackson, Elaine

    1978-01-01

    Presents a study of decalage between object permanence and person permanence. Decalage was influenced by environmental as well as stimulus factors with infants tested between 6- and 81/4-months/of-age. (BD)

  19. Test Cost and Test Accuracy in Clinical Laboratories in Kampala, Uganda.

    Science.gov (United States)

    Amukele, Timothy K; Jones, Robert; Elbireer, Ali

    2018-04-25

    To assess the accuracy and costs of laboratory tests in Kampala, Uganda. A random selection of 78 laboratories tested external quality assurance samples at market rates. There were 40 moderate- to high-complexity and 38 low-complexity laboratories. Four percent (3/78) of these laboratories were accredited and 94% (73/78) were private. The 40 moderate- to high-complexity laboratories performed malaria blood smear, urine human chorionic gonadotropin (hCG), human immunodeficiency virus (HIV), syphilis, glucose, and three-panel tests: CBC, liver function tests, and kidney function tests. The 38 low-complexity laboratories performed malaria blood smear, urine hCG, and syphilis testing only. Hematology, HIV, syphilis, and malarial proficiency testing samples were prepared by accredited laboratories in Kampala. All other samples were provided by the Royal College of Pathologists of Australia. 77.1% of all results were accurate (met target values). It varied widely by laboratory (50%-100%), test identity (malaria blood smear, 96%; serum urea nitrogen, 38%), and test type (quantitative: 66% [31%-89%], qualitative: 91% [68%-97%]). Test prices varied by up to 3,600%, and there was no correlation between test cost and accuracy (r2 = 0.02). There were large differences in accuracy and price across laboratories in Kampala. Price was not associated with quality.

  20. 30 CFR 75.1912 - Fire suppression systems for permanent underground diesel fuel storage facilities.

    Science.gov (United States)

    2010-07-01

    ... Diesel-Powered Equipment § 75.1912 Fire suppression systems for permanent underground diesel fuel storage... system by a nationally recognized independent testing laboratory and appropriate for installation at a... recommended inspection and maintenance program and as required by the nationally recognized independent...

  1. Anthropomorphic Test Drive (ATD) Certification Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The ATD Certification Laboratory consists of several test fixtures to ensure ATDs are functioning correctly and within specifications prior to use in any OP testing....

  2. Electromedical devices test laboratories accreditation

    International Nuclear Information System (INIS)

    Murad, C; Rubio, D; Ponce, S; Alvarez Abri, A; Terron, A; Vicencio, D; Fascioli, E

    2007-01-01

    In the last years, the technology and equipment at hospitals have been increase in a great way as the risks of their implementation. Safety in medical equipment must be considered an important issue to protect patients and their users. For this reason, test and calibrations laboratories must verify the correct performance of this kind of devices under national and international standards. Is an essential mission for laboratories to develop their measurement activities taking into account a quality management system. In this article, we intend to transmit our experience working to achieve an accredited Test Laboratories for medical devices in National technological University

  3. Relay testing at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Bandyopadhyay, K.; Hofmayer, C.

    1989-01-01

    Brookhaven National Laboratory (BNL) is conducting a seismic test program on relays. The purpose of the test program is to investigate the influence of various designs, electrical and vibration parameters on the seismic capacity levels. The first series of testing has been completed and performed at Wyle Laboratories. The major part of the test program consisted of single axis, single frequency sine dwell tests. Random multiaxis, multifrequency tests were also performed. Highlights of the test results as well as a description of the testing methods are presented in this paper. 10 figs

  4. Analysis of Properties of Reflectance Reference Targets for Permanent Radiometric Test Sites of High Resolution Airborne Imaging Systems

    Directory of Open Access Journals (Sweden)

    Eero Ahokas

    2010-08-01

    Full Text Available Reliable and optimal exploitation of rapidly developing airborne imaging methods requires geometric and radiometric quality assurance of production systems in operational conditions. Permanent test sites are the most promising approach for cost-efficient performance assessment. Optimal construction of permanent radiometric test sites for high resolution airborne imaging systems is an unresolved issue. The objective of this study was to assess the performance of commercially available gravels and painted and unpainted concrete targets for permanent, open-air radiometric test sites under sub-optimal climate conditions in Southern Finland. The reflectance spectrum and reflectance anisotropy and their stability were characterized during the summer of 2009. The management of reflectance anisotropy and stability were shown to be the key issues for better than 5% reflectance accuracy.

  5. [How do hospital clinical laboratories and laboratory testing companies cooperate and build reciprocal relations?].

    Science.gov (United States)

    Kawano, Seiji

    2014-12-01

    As the 2nd Joint Symposium of the Japanese Society of Laboratory Medicine and the Japanese Association of Laboratory Pathologists, the symposium on clinical test out-sourcing and branch laboratories was held at the 60th General Meeting of the Japanese Society of Laboratory Medicine on November 2nd, 2013 in Kobe. For the symposium, we conducted a questionnaire survey on the usage of clinical test out-sourcing and the introduction of branch laboratories to clinical laboratories of Japanese university hospitals, both private and public, between July 25th and August 20th, 2013. Seventy-two hospitals responded to the questionnaire survey, consisting of 41 public medical school hospitals and 31 private ones. According to the survey, the selection of each clinical test for out-sourcing was mainly determined by the capacities of hospital clinical laboratories and their equipment, as well as the profitability of each test. The main concerns of clinical laboratory members of university hospitals involved the continuity of measurement principles, traceability, and standardization of reference values for each test. They strongly requested the interchangeability and computerization of test data between laboratory testing companies. A branch laboratory was introduced to six hospitals, all of which were private medical college hospitals, out of 72 university hospitals, and eight of the other hospitals were open to its introduction. The merits and demerits of introducing a branch laboratory were also discussed. (Review).

  6. Object permanence in lemurs.

    Science.gov (United States)

    Deppe, Anja M; Wright, Patricia C; Szelistowski, William A

    2009-03-01

    Object permanence, the ability to mentally represent objects that have disappeared from view, should be advantageous to animals in their interaction with the natural world. The objective of this study was to examine whether lemurs possess object permanence. Thirteen adult subjects representing four species of diurnal lemur (Eulemur fulvus rufus, Eulemur mongoz, Lemur catta and Hapalemur griseus) were presented with seven standard Piagetian visible and invisible object displacement tests, plus one single visible test where the subject had to wait predetermined times before allowed to search, and two invisible tests where each hiding place was made visually unique. In all visible tests lemurs were able to find an object that had been in clear view before being hidden. However, when lemurs were not allowed to search for up to 25-s, performance declined with increasing time-delay. Subjects did not outperform chance on any invisible displacements regardless of whether hiding places were visually uniform or unique, therefore the upper limit of object permanence observed was Stage 5b. Lemur species in this study eat stationary foods and are not subject to stalking predators, thus Stage 5 object permanence is probably sufficient to solve most problems encountered in the wild.

  7. Laboratory for filter testing

    Energy Technology Data Exchange (ETDEWEB)

    Paluch, W.

    1987-07-01

    Filters used for mine draining in brown coal surface mines are tested by the Mine Draining Department of Poltegor. Laboratory tests of new types of filters developed by Poltegor are analyzed. Two types of tests are used: tests of scale filter models and tests of experimental units of new filters. Design and operation of the test stands used for testing mechanical properties and hydraulic properties of filters for coal mines are described: dimensions, pressure fluctuations, hydraulic equipment. Examples of testing large-diameter filters for brown coal mines are discussed.

  8. Laboratory Testing of Waste Isolation Pilot Plant Surrogate Waste Materials

    Science.gov (United States)

    Broome, S.; Bronowski, D.; Pfeifle, T.; Herrick, C. G.

    2011-12-01

    The Waste Isolation Pilot Plant (WIPP) is a U.S. Department of Energy geological repository for the permanent disposal of defense-related transuranic (TRU) waste. The waste is emplaced in rooms excavated in the bedded Salado salt formation at a depth of 655 m below the ground surface. After emplacement of the waste, the repository will be sealed and decommissioned. WIPP Performance Assessment modeling of the underground material response requires a full and accurate understanding of coupled mechanical, hydrological, and geochemical processes and how they evolve with time. This study was part of a broader test program focused on room closure, specifically the compaction behavior of waste and the constitutive relations to model this behavior. The goal of this study was to develop an improved waste constitutive model. The model parameters are developed based on a well designed set of test data. The constitutive model will then be used to realistically model evolution of the underground and to better understand the impacts on repository performance. The present study results are focused on laboratory testing of surrogate waste materials. The surrogate wastes correspond to a conservative estimate of the degraded containers and TRU waste materials after the 10,000 year regulatory period. Testing consists of hydrostatic, uniaxial, and triaxial tests performed on surrogate waste recipes that were previously developed by Hansen et al. (1997). These recipes can be divided into materials that simulate 50% and 100% degraded waste by weight. The percent degradation indicates the anticipated amount of iron corrosion, as well as the decomposition of cellulosics, plastics, and rubbers. Axial, lateral, and volumetric strain and axial and lateral stress measurements were made. Two unique testing techniques were developed during the course of the experimental program. The first involves the use of dilatometry to measure sample volumetric strain under a hydrostatic condition. Bulk

  9. [Quality use of commercial laboratory for clinical testing services - considering laboratory's role].

    Science.gov (United States)

    Ogawa, Shinji

    2014-12-01

    The number of commercial laboratories for clinical testing in Japan run privately has decreased to about 30 companies, and their business is getting tougher. Branch Lab. and FMS businesses have not expanded recently due to the new reimbursement system which adds an additional sample management fee, becoming effective in 2010. This presentation gives an outline of each role for hospital and commercial laboratories, and their pros & cons considering the current medical situation. Commercial laboratories have investigated how to utilize ICT systems for sharing test information between hospitals and our facilities. It would be very helpful to clarify issues for each hospital. We will develop and create new values for clinical laboratory testing services and forge mutually beneficial relationships with medical institutions. (Review).

  10. Fuel Cell Development and Test Laboratory | Energy Systems Integration

    Science.gov (United States)

    Facility | NREL Fuel Cell Development and Test Laboratory Fuel Cell Development and Test Laboratory The Energy System Integration Facility's Fuel Cell Development and Test Laboratory supports fuel cell research and development projects through in-situ fuel cell testing. Photo of a researcher running

  11. Energy Systems High-Pressure Test Laboratory | Energy Systems Integration

    Science.gov (United States)

    Facility | NREL Energy Systems High-Pressure Test Laboratory Energy Systems High-Pressure Test Laboratory In the Energy Systems Integration Facility's High-Pressure Test Laboratory, researchers can safely test high-pressure hydrogen components. Photo of researchers running an experiment with a hydrogen fuel

  12. Tests of planar permanent magnet multipole focusing elements

    International Nuclear Information System (INIS)

    Cobb, J.; Tatchyn, R.

    1993-08-01

    In recent work, planar configurations of permanent magnets were proposed as substitutes for conventional current-driven iron quadrupoles in applications limited by small aperture sizes and featuring small beam occupation diameters. Important examples include the configuring of focusing lattices in small-gap insertion devices, and the implementation of compact mini-beta sections on linear or circular machines. In subsequent analysis, this approach was extended to sextupoles and higher-order multipoles. In this paper we report on initial measurements conducted at the Stanford Linear Accelerator Center on recently fabricated planar permanent magnet quadrupoles and sextupoles configured out of SmCo and NdFe/B

  13. Evaluation of Mycology Laboratory Proficiency Testing

    Science.gov (United States)

    Reilly, Andrew A.; Salkin, Ira F.; McGinnis, Michael R.; Gromadzki, Sally; Pasarell, Lester; Kemna, Maggi; Higgins, Nancy; Salfinger, Max

    1999-01-01

    Changes over the last decade in overt proficiency testing (OPT) regulations have been ostensibly directed at improving laboratory performance on patient samples. However, the overt (unblinded) format of the tests and regulatory penalties associated with incorrect values allow and encourage laboratorians to take extra precautions with OPT analytes. As a result OPT may measure optimal laboratory performance instead of the intended target of typical performance attained during routine patient testing. This study addresses this issue by evaluating medical mycology OPT and comparing its fungal specimen identification error rates to those obtained in a covert (blinded) proficiency testing (CPT) program. Identifications from 188 laboratories participating in the New York State mycology OPT from 1982 to 1994 were compared with the identifications of the same fungi recovered from patient specimens in 1989 and 1994 as part of the routine procedures of 88 of these laboratories. The consistency in the identification of OPT specimens was sufficient to make accurate predictions of OPT error rates. However, while the error rates in OPT and CPT were similar for Candida albicans, significantly higher error rates were found in CPT for Candida tropicalis, Candida glabrata, and other common pathogenic fungi. These differences may, in part, be due to OPT’s use of ideal organism representatives cultured under optimum growth conditions. This difference, as well as the organism-dependent error rate differences, reflects the limitations of OPT as a means of assessing the quality of routine laboratory performance in medical mycology. PMID:10364601

  14. Evaluation of Mycology Laboratory Proficiency Testing

    OpenAIRE

    Reilly, Andrew A.; Salkin, Ira F.; McGinnis, Michael R.; Gromadzki, Sally; Pasarell, Lester; Kemna, Maggi; Higgins, Nancy; Salfinger, Max

    1999-01-01

    Changes over the last decade in overt proficiency testing (OPT) regulations have been ostensibly directed at improving laboratory performance on patient samples. However, the overt (unblinded) format of the tests and regulatory penalties associated with incorrect values allow and encourage laboratorians to take extra precautions with OPT analytes. As a result OPT may measure optimal laboratory performance instead of the intended target of typical performance attained during routine patient te...

  15. Antimicrobial susceptibility testing by Australian veterinary diagnostic laboratories.

    Science.gov (United States)

    Hardefeldt, L Y; Marenda, M; Crabb, H; Stevenson, M A; Gilkerson, J R; Billman-Jacobe, H; Browning, G F

    2018-04-01

    The national strategy for tackling antimicrobial resistance highlights the need for antimicrobial stewardship in veterinary practice and for surveillance of antimicrobial susceptibility in veterinary pathogens. Diagnostic laboratories have an important role in facilitating both of these processes, but it is unclear whether data from veterinary diagnostic laboratories are similar enough to allow for compilation and if there is consistent promotion of appropriate antimicrobial use embedded in the approaches of different laboratories to susceptibility testing. A cross-sectional study of antimicrobial susceptibility testing and reporting procedures by Australian veterinary diagnostic laboratories was conducted in 2017 using an online questionnaire. All 18 veterinary diagnostic laboratories in Australia completed the questionnaire. Kirby-Bauer disc diffusion was the method predominantly used for antimicrobial susceptibility testing and was used to evaluate 86% of all isolates, although two different protocols were used across the 18 laboratories (CLSI 15/18, CDS 3/18). Minimum inhibitory concentrations were never reported by 61% of laboratories. Common isolates were consistently reported on across all species, except for gram-negative isolates in pigs, for which there was some variation in the approach to reporting. There was considerable diversity in the panels of antimicrobials used for susceptibility testing on common isolates and no consistency was apparent between laboratories for any bacterial species. We recommend that nationally agreed and consistent antimicrobial panels for routine susceptibility testing should be developed and a uniform set of guidelines should be adopted by veterinary diagnostic laboratories in Australia. © 2018 Australian Veterinary Association.

  16. Recommended procedures for performance testing of radiobioassay laboratories: Volume 3, In vivo test phantoms

    International Nuclear Information System (INIS)

    MacLellan, J.A.; Traub, R.J.

    1988-11-01

    Draft American National Standards Institute (ANSI) Standard N13.30 (Performance Criteria for Radiobioassay) was developed for the US Department of Energy and the US Nuclear Regulatory Commission to help ensure that bioassay laboratories provide accurate and consistent results. The draft standard describes the procedures necessary to establish a bioassay performance-testing laboratory and program. The bioassay performance-testing laboratory will conduct tests to evaluate the performance of service laboratories. Pacific Northwest Laboratory helped develop testing procedures as part of an effort to evaluate the draft ANSI N13.30 performance criteria by testing the existing measurement capabilities of various bioassay laboratories. This report recommends guidelines for the preparation, handling, storage, distribution, shipping, and documentation of test phantoms used for calibration of measurement systems for direct bioassay. The data base and recommended records system for documenting radiobioassay performance at the service laboratories are also presented

  17. Testing activities at the National Battery Test Laboratory

    Science.gov (United States)

    Hornstra, F.; Deluca, W. H.; Mulcahey, T. P.

    The National Battery Test Laboratory (NBTL) is an Argonne National Laboratory facility for testing, evaluating, and studying advanced electric storage batteries. The facility tests batteries developed under Department of Energy programs and from private industry. These include batteries intended for future electric vehicle (EV) propulsion, electric utility load leveling (LL), and solar energy storage. Since becoming operational, the NBTL has evaluated well over 1400 cells (generally in the form of three- to six-cell modules, but up to 140-cell batteries) of various technologies. Performance characterization assessments are conducted under a series of charge/discharge cycles with constant current, constant power, peak power, and computer simulated dynamic load profile conditions. Flexible charging algorithms are provided to accommodate the specific needs of each battery under test. Special studies are conducted to explore and optimize charge procedures, to investigate the impact of unique load demands on battery performance, and to analyze the thermal management requirements of battery systems.

  18. Development of HMPE fiber for deep water permanent mooring applications

    Energy Technology Data Exchange (ETDEWEB)

    Vlasblom, Martin; Fronzaglia, Bill; Boesten, Jorn [DSM Dyneema, Urmond (Netherlands); Leite, Sergio [Lankhorst Ropes, Sneek (Netherlands); Davies, Peter [Institut Francais de Recherche pour L' Exploration de la Mer (IFREMER) (France)

    2012-07-01

    For a number of years, the creep performance of standard High Modulus Polyethylene (HMPE) fiber types has limited their use in synthetic offshore mooring systems. In 2003, a low creep HMPE fiber was introduced and qualified for semi-permanent MODU moorings. This paper reports on a new High Modulus Polyethylene fiber type with significantly improved creep properties compared to any other HMPE fiber type, which, for the first time, allows its use in permanent offshore mooring systems, for example for deep water FPSO moorings. Results on fiber and rope creep experiments and stiffness measurements are reported. Laboratory testing shows that ropes made with the new fiber type retain the properties characteristic of HMPE such as high static strength, high fatigue resistance and stiffness, and illustrate that stiffness properties determined on HMPE fiber or rope are dependent on the applied load and temperature. (author)

  19. Permanent quadrupole magnets

    International Nuclear Information System (INIS)

    Bush, E.D. Jr.

    1976-01-01

    A family of quadrupole magnets using a soft iron return yoke and circular cross-section permanent magnet poles were fabricated to investigate the feasibility for use in ion or electron beam focusing applications in accelerators and transport lines. Magnetic field measurements yielded promising results. In fixed-field applications, permanent magnets with sufficient gradients would be a low cost substitute for conventional electromagnets, eliminating the need for power supplies, associated wiring, and cooling. Based on preliminary tests, it was seen that permanent quadrupole magnets can offer a low cost, reliable solution in applications requiring small, fixed-field focusing devices for use in ion or electron-beam transport systems. Permanent magnets do require special considerations in design, fabrication, handling, and service that are different than encountered in conventional quadrupole magnets. If these basic conditions are satisfied, the resulting beam-focusing device would be stable, maintenance free, with virtually an indefinite lifetime

  20. In situ vitrification laboratory-scale test work plan

    International Nuclear Information System (INIS)

    Nagata, P.K.; Smith, N.L.

    1991-05-01

    The Buried Waste Program was established in October 1987 to accelerate the studies needed to develop a long-term management plan for the buried mixed waste at the Radioactive Waste Management Complex at Idaho Engineering Laboratory. The In Situ Vitrification Project is being conducted in a Comprehensive Environmental Response, Compensation, and Liability Act feasibility study format to identify methods for the long-term management of mixed buried waste. To support the overall feasibility study, the situ vitrification treatability investigations are proceeding along the three parallel paths: laboratory-scale tests, intermediate field tests, and field tests. Laboratory-scale tests are being performed to provide data to mathematical modeling efforts, which, in turn, will support design of the field tests and to the health and safety risk assessment. This laboratory-scale test work plan provides overall testing program direction to meet the current goals and objectives of the in situ vitrification treatability investigation. 12 refs., 1 fig., 7 tabs

  1. Application of heat pipe technology in permanent mold casting of nonferrous alloys

    Science.gov (United States)

    Elalem, Kaled

    The issue of mold cooling is one, which presents a foundry with a dilemma. On the one hand; the use of air for cooling is safe and practical, however, it is not very effective and high cost. On the other hand, water-cooling can be very effective but it raises serious concerns about safety, especially with a metal such as magnesium. An alternative option that is being developed at McGill University uses heat pipe technology to carry out the cooling. The experimental program consisted of designing a permanent mold to produce AZ91E magnesium alloy and A356 aluminum alloy castings with shrinkage defects. Heat pipes were then used to reduce these defects. The heat pipes used in this work are novel and are patent pending. They are referred to as McGill Heat Pipes. Computer modeling was used extensively in designing the mold and the heat pipes. Final designs for the mold and the heat pipes were chosen based on the modeling results. Laboratory tests of the heat pipe were performed before conducting the actual experimental plan. The laboratory testing results verified the excellent performance of the heat pipes as anticipated by the model. An industrial mold made of H13 tool steel was constructed to cast nonferrous alloys. The heat pipes were installed and initial testing and actual industrial trials were conducted. This is the first time where a McGill heat pipe was used in an industrial permanent mold casting process for nonferrous alloys. The effects of cooling using heat pipes on AZ91E and A356 were evaluated using computer modeling and experimental trials. Microstructural analyses were conducted to measure the secondary dendrite arm spacing, SDAS, and the grain size to evaluate the cooling effects on the castings. The modeling and the experimental results agreed quite well. The metallurgical differences between AZ91E and A356 were investigated using modeling and experimental results. Selected results from modeling, laboratory and industrial trials are presented. The

  2. BENCHMARKING MOBILE LASER SCANNING SYSTEMS USING A PERMANENT TEST FIELD

    Directory of Open Access Journals (Sweden)

    H. Kaartinen

    2012-07-01

    Full Text Available The objective of the study was to benchmark the geometric accuracy of mobile laser scanning (MLS systems using a permanent test field under good coverage of GNSS. Mobile laser scanning, also called mobile terrestrial laser scanning, is currently a rapidly developing area in laser scanning where laser scanners, GNSS and IMU are mounted onboard a moving vehicle. MLS can be considered to fill the gap between airborne and terrestrial laser scanning. Data provided by MLS systems can be characterized with the following technical parameters: a point density in the range of 100-1000 points per m2 at 10 m distance, b distance measurement accuracy of 2-5 cm, and c operational scanning range from 1 to 100 m. Several commercial, including e.g. Riegl, Optech and others, and some research mobile laser scanning systems surveyed the test field using predefined driving speed and directions. The acquired georeferenced point clouds were delivered for analyzing. The geometric accuracy of the point clouds was determined using the reference targets that could be identified and measured from the point cloud. Results show that in good GNSS conditions most systems can reach an accuracy of 2 cm both in plane and elevation. The accuracy of a low cost system, the price of which is less than tenth of the other systems, seems to be within a few centimetres at least in ground elevation determination. Inaccuracies in the relative orientation of the instruments lead to systematic errors and when several scanners are used, in multiple reproductions of the objects. Mobile laser scanning systems can collect high density point cloud data with high accuracy. A permanent test field suits well for verifying and comparing the performance of different mobile laser scanning systems. The accuracy of the relative orientation between the mapping instruments needs more attention. For example, if the object is seen double in the point cloud due to imperfect boresight calibration between two

  3. Sandia Laboratories technical capabilities: testing

    International Nuclear Information System (INIS)

    Lundergan, C.D.

    1975-12-01

    The testing capabilities at Sandia Laboratories are characterized. Selected applications of these capabilities are presented to illustrate the extent to which they can be applied in research and development programs

  4. Total laboratory automation: Do stat tests still matter?

    Science.gov (United States)

    Dolci, Alberto; Giavarina, Davide; Pasqualetti, Sara; Szőke, Dominika; Panteghini, Mauro

    2017-07-01

    During the past decades the healthcare systems have rapidly changed and today hospital care is primarily advocated for critical patients and acute treatments, for which laboratory test results are crucial and need to be always reported in predictably short turnaround time (TAT). Laboratories in the hospital setting can face this challenge by changing their organization from a compartmentalized laboratory department toward a decision making-based laboratory department. This requires the implementation of a core laboratory, that exploits total laboratory automation (TLA) using technological innovation in analytical platforms, track systems and information technology, including middleware, and a number of satellite specialized laboratory sections cooperating with care teams for specific medical conditions. In this laboratory department model, the short TAT for all first-line tests performed by TLA in the core laboratory represents the key paradigm, where no more stat testing is required because all samples are handled in real-time and (auto)validated results dispatched in a time that fulfills clinical needs. To optimally reach this goal, laboratories should be actively involved in managing all the steps covering the total examination process, speeding up also extra-laboratory phases, such sample delivery. Furthermore, to warrant effectiveness and not only efficiency, all the processes, e.g. specimen integrity check, should be managed by middleware through a predefined set of rules defined in light of the clinical governance. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  5. Sensitivity and Specificity of Clinical and Laboratory Otolith Function Tests.

    Science.gov (United States)

    Kumar, Lokesh; Thakar, Alok; Thakur, Bhaskar; Sikka, Kapil

    2017-10-01

    To evaluate clinic based and laboratory tests of otolith function for their sensitivity and specificity in demarcating unilateral compensated complete vestibular deficit from normal. Prospective cross-sectional study. Tertiary care hospital vestibular physiology laboratory. Control group-30 healthy adults, 20-45 years age; Case group-15 subjects post vestibular shwannoma excision or post-labyrinthectomy with compensated unilateral complete audio-vestibular loss. Otolith function evaluation by precise clinical testing (head tilt test-HTT; subjective visual vertical-SVV) and laboratory testing (headroll-eye counterroll-HR-ECR; vesibular evoked myogenic potentials-cVEMP). Sensitivity and specificity of clinical and laboratory tests in differentiating case and control subjects. Measurable test results were universally obtained with clinical otolith tests (SVV; HTT) but not with laboratory tests. The HR-ECR test did not indicate any definitive wave forms in 10% controls and 26% cases. cVEMP responses were absent in 10% controls.HTT test with normative cutoff at 2 degrees deviations from vertical noted as 93.33% sensitive and 100% specific. SVV test with normative cutoff at 1.3 degrees noted as 100% sensitive and 100% specific. Laboratory tests demonstrated poorer specificities owing primarily to significant unresponsiveness in normal controls. Clinical otolith function tests, if conducted with precision, demonstrate greater ability than laboratory testing in discriminating normal controls from cases with unilateral complete compensated vestibular dysfunction.

  6. Impact of Laboratory Test Use Strategies in a Turkish Hospital.

    Directory of Open Access Journals (Sweden)

    Fatma Meriç Yılmaz

    Full Text Available Eliminating unnecessary laboratory tests is a good way to reduce costs while maintain patient safety. The aim of this study was to define and process strategies to rationalize laboratory use in Ankara Numune Training and Research Hospital (ANH and calculate potential savings in costs.A collaborative plan was defined by hospital managers; joint meetings with ANHTA and laboratory professors were set; the joint committee invited relevant staff for input, and a laboratory efficiency committee was created. Literature was reviewed systematically to identify strategies used to improve laboratory efficiency. Strategies that would be applicable in local settings were identified for implementation, processed, and the impact on clinical use and costs assessed for 12 months.Laboratory use in ANH differed enormously among clinics. Major use was identified in internal medicine. The mean number of tests per patient was 15.8. Unnecessary testing for chloride, folic acid, free prostate specific antigen, hepatitis and HIV testing were observed. Test panel use was pinpointed as the main cause of overuse of the laboratory and the Hospital Information System test ordering page was reorganized. A significant decrease (between 12.6-85.0% was observed for the tests that were taken to an alternative page on the computer screen. The one year study saving was equivalent to 371,183 US dollars.Hospital-based committees including laboratory professionals and clinicians can define hospital based problems and led to a standardized approach to test use that can help clinicians reduce laboratory costs through appropriate use of laboratory tests.

  7. Influence of diet on the results of laboratory tests

    Directory of Open Access Journals (Sweden)

    Kinga Lis

    2013-12-01

    Full Text Available Blood and urine laboratory tests are necessary to diagnose the state of the patient. These tests are also helpful in the assessment of diet and nutritional status of the organism. It is recommended that both blood and urine for laboratory tests be collected in the morning, from fasting patients after an overnight rest. These conditions are defined as the standard conditions for collection of material for laboratory testing. Before testing, patients should follow their natural diet and avoid physical exertion, night work, long-distance travel, as well as consumption of alcohol and drugs. They should also reduce the consumption of synthetic vitamins and herbal remedies and other dietary supplements. Medications should be limited to those that are absolutely necessary. All of these factors can affect the results of laboratory tests.

  8. Point-of-Care Test Equipment for Flexible Laboratory Automation.

    Science.gov (United States)

    You, Won Suk; Park, Jae Jun; Jin, Sung Moon; Ryew, Sung Moo; Choi, Hyouk Ryeol

    2014-08-01

    Blood tests are some of the core clinical laboratory tests for diagnosing patients. In hospitals, an automated process called total laboratory automation, which relies on a set of sophisticated equipment, is normally adopted for blood tests. Noting that the total laboratory automation system typically requires a large footprint and significant amount of power, slim and easy-to-move blood test equipment is necessary for specific demands such as emergency departments or small-size local clinics. In this article, we present a point-of-care test system that can provide flexibility and portability with low cost. First, the system components, including a reagent tray, dispensing module, microfluidic disk rotor, and photometry scanner, and their functions are explained. Then, a scheduler algorithm to provide a point-of-care test platform with an efficient test schedule to reduce test time is introduced. Finally, the results of diagnostic tests are presented to evaluate the system. © 2014 Society for Laboratory Automation and Screening.

  9. Laboratory development and testing of spacecraft diagnostics

    Science.gov (United States)

    Amatucci, William; Tejero, Erik; Blackwell, Dave; Walker, Dave; Gatling, George; Enloe, Lon; Gillman, Eric

    2017-10-01

    The Naval Research Laboratory's Space Chamber experiment is a large-scale laboratory device dedicated to the creation of large-volume plasmas with parameters scaled to realistic space plasmas. Such devices make valuable contributions to the investigation of space plasma phenomena under controlled, reproducible conditions, allowing for the validation of theoretical models being applied to space data. However, in addition to investigations such as plasma wave and instability studies, such devices can also make valuable contributions to the development and testing of space plasma diagnostics. One example is the plasma impedance probe developed at NRL. Originally developed as a laboratory diagnostic, the sensor has now been flown on a sounding rocket, is included on a CubeSat experiment, and will be included on the DoD Space Test Program's STP-H6 experiment on the International Space Station. In this talk, we will describe how the laboratory simulation of space plasmas made this development path possible. Work sponsored by the US Naval Research Laboratory Base Program.

  10. Iowa Central Quality Fuel Testing Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Heach, Don; Bidieman, Julaine

    2013-09-30

    The objective of this project is to finalize the creation of an independent quality fuel testing laboratory on the campus of Iowa Central Community College in Fort Dodge, Iowa that shall provide the exploding biofuels industry a timely and cost-effective centrally located laboratory to complete all state and federal fuel and related tests that are required. The recipient shall work with various state regulatory agencies, biofuel companies and state and national industry associations to ensure that training and testing needs of their members and American consumers are met. The recipient shall work with the Iowa Department of Ag and Land Stewardship on the development of an Iowa Biofuel Quality Standard along with the Development of a standard that can be used throughout industry.

  11. Test plan for ISV laboratory-pyrolysis testing

    Energy Technology Data Exchange (ETDEWEB)

    McAtee, R.E.

    1991-09-01

    The objective of the laboratory-pyrolysis studies is to obtain information on the high temperature (< 1200{degree}C) degradation and alteration of organic chemicals and materials similar to those found in the Radioactive Waste Management Complex, Pit 9. This test plan describes experimental procedures, sampling and analysis strategy, sampling procedures, sample control, and document management. It addresses safety issues in the experimental apparatus and procedures, personal training, and hazardous waste disposal. Finally, it describes the data quality objectives using the EPA tiered approach to treatability studies to define where research/scoping tests fit into these studies and the EPA analytical levels required for the tests.

  12. Manual on laboratory testing for uranium ore processing

    International Nuclear Information System (INIS)

    1990-01-01

    Laboratory testing of uranium ores is an essential step in the economic evaluation of uranium occurrences and in the development of a project for the production of uranium concentrates. Although these tests represent only a small proportion of the total cost of a project, their proper planning, execution and interpretation are of crucial importance. The main purposes of this manual are to discuss the objectives of metallurgical laboratory ore testing, to show the specific role of these tests in the development of a project, and to provide practical instructions for performing the tests and for interpreting their results. Guidelines on the design of a metallurgical laboratory, on the equipment required to perform the tests and on laboratory safety are also given. This manual is part of a series of Technical Reports on uranium ore processing being prepared by the IAEA's Division of Nuclear Fuel Cycle and Waste Management. A report on the Significance of Mineralogy in the Development of Flowsheets for Processing Uranium Ores (Technical Reports Series No. 196, 1980) and an instruction manual on Methods for the Estimation of Uranium Ore Reserves (No. 255, 1985) have already been published. 17 refs, 40 figs, 17 tabs

  13. Centrifugal contractors for laboratory-scale solvent extraction tests

    International Nuclear Information System (INIS)

    Leonard, R.A.; Chamberlain, D.B.; Conner, C.

    1995-01-01

    A 2-cm contactor (minicontactor) was developed and used at Argonne National Laboratory for laboratory-scale testing of solvent extraction flowsheets. This new contactor requires only 1 L of simulated waste feed, which is significantly less than the 10 L required for the 4-cm unit that had previously been used. In addition, the volume requirements for the other aqueous and organic feeds are reduced correspondingly. This paper (1) discusses the design of the minicontactor, (2) describes results from having applied the minicontactor to testing various solvent extraction flowsheets, and (3) compares the minicontactor with the 4-cm contactor as a device for testing solvent extraction flowsheets on a laboratory scale

  14. 19 CFR 151.54 - Testing by Customs laboratory.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Testing by Customs laboratory. 151.54 Section 151.54 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF... Other Metal-Bearing Materials § 151.54 Testing by Customs laboratory. Samples taken in accordance with...

  15. Permanent magnet quadrupoles for the CLIC Drive Beam decelerator

    CERN Document Server

    Shepherd, Ben; Collomb, Norbert

    2012-01-01

    STFC in collaboration with CERN has developed a new type of adjustable permanent magnet based quadrupole for the CLIC Drive Beam Decelerator. It uses vertical movement of the permanent magnets to achieve an integrated gradient range of 3.6-14.6T, which will allow it to be used for the first 60% of the decelerator line. Construction of a prototype of this magnet has begun; following this, it will be measured magnetically at CERN and Daresbury Laboratory.

  16. 7 CFR 58.523 - Laboratory and quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability of...

  17. Laboratory testing improves diagnosis and treatment outcomes in primary health care facilities

    Directory of Open Access Journals (Sweden)

    Jane Y. Carter

    2012-10-01

    Setting: Six rural health centres in Kenya. Design: Cross-sectional study to observe change in diagnosis and treatment made by clinical officers after laboratory testing in outpatients attending six rural health centres in Kenya. Subject: The diagnosis and treatment of 1134 patients attending outpatient services in six rural health centres were compared before and after basic laboratory testing. Essential clinical diagnostic equipment and laboratory tests were established at each health centre. Clinical officers and laboratory technicians received on-site refresher training in good diagnostic practices and laboratory procedures before the study began. Results: Laboratory tests were ordered on 704 (62.1% patients. Diagnosis and treatment were changed in 45% of tested patients who returned with laboratory results (21% of all patients attending the clinics. 166 (23.5% patients did not return to the clinician for a final diagnosis and management decision after laboratory testing. Blood slide examination for malaria parasites, wet preparations, urine microscopy and stool microscopy resulted in most changes to diagnosis. There was no significant change in drug costs after laboratory testing. The greatest changes in numbers of recorded diseases following laboratory testing was for intestinal worms (53% and malaria (21%. Conclusion: Effective use of basic laboratory tests at primary health care level significantly improves diagnosis and patient treatment. Use of laboratory testing can be readily incorporated into routine clinical practice. On-site refresher training is an effective means of improving the quality of patient care and communication between clinical and laboratory staff.

  18. 222-S LABORATORY FUME HOOD TESTING STUDY

    International Nuclear Information System (INIS)

    RUELAS, B.H.

    2007-01-01

    The 222-S Laboratory contains 155 active fume hoods that are used to support analytical work with radioactive and/or toxic materials. The performance of a fume hood was brought into question after employees detected odors in the work area while mixing chemicals within the subject fume hood. Following the event, testing of the fume hood was conducted to assess the performance of the fume hood. Based on observations from the testing, it was deemed appropriate to conduct performance evaluations of other fume hoods within the laboratory

  19. Closing the brain-to-brain loop in laboratory testing.

    Science.gov (United States)

    Plebani, Mario; Lippi, Giuseppe

    2011-07-01

    Abstract The delivery of laboratory services has been described 40 years ago and defined with the foremost concept of "brain-to-brain turnaround time loop". This concept consists of several processes, including the final step which is the action undertaken on the patient based on laboratory information. Unfortunately, the need for systematic feedback to improve the value of laboratory services has been poorly understood and, even more risky, poorly applied in daily laboratory practice. Currently, major problems arise from the unavailability of consensually accepted quality specifications for the extra-analytical phase of laboratory testing. This, in turn, does not allow clinical laboratories to calculate a budget for the "patient-related total error". The definition and use of the term "total error" refers only to the analytical phase, and should be better defined as "total analytical error" to avoid any confusion and misinterpretation. According to the hierarchical approach to classify strategies to set analytical quality specifications, the "assessment of the effect of analytical performance on specific clinical decision-making" is comprehensively at the top and therefore should be applied as much as possible to address analytical efforts towards effective goals. In addition, an increasing number of laboratories worldwide are adopting risk management strategies such as FMEA, FRACAS, LEAN and Six Sigma since these techniques allow the identification of the most critical steps in the total testing process, and to reduce the patient-related risk of error. As a matter of fact, an increasing number of laboratory professionals recognize the importance of understanding and monitoring any step in the total testing process, including the appropriateness of the test request as well as the appropriate interpretation and utilization of test results.

  20. Clinical Laboratory Tests in Some Acute Exogenous Poisonings.

    Science.gov (United States)

    Tufkova, Stoilka G; Yankov, Ivan V; Paskaleva, Diana A

    2017-09-01

    There is no specific toxicological screening of clinical laboratory parameters in clinical toxicology when it comes to acute exogenous poisoning. To determine routine clinical laboratory parameters and indicators for assessment of vital functions in patients with acute intoxications. One hundred and fifty-three patients were included in the present study. They were hospitalized in the Department of Clinical Toxicology at St. George University Hospital, Plovdiv for cerebral toxicity inducing medication (n = 45), alcohol (n = 40), heroin abuse (n = 33). The controls were 35. The laboratory tests were conducted in compliance with the standards of the clinical laboratory. We used the following statistical analyses: analysis of variance (the ucriterion of normal distribution, the Student's t-test, dispersion analysis based on ANOVA) and non-parametric analysis. Based on the routine hematological parameters with statistically significant changes in three groups of poisoning are: red blood cells, hematocrit, hemoglobin (except alcohol intoxication) and leukocytes. We found statistically significant changes in serum total protein, sodium and bilirubin. The highest statistical significance is the increased activity of AST and ALT. We present a model for selection of clinical laboratory tests for severe acute poisoning with modern equipment under standardized conditions. The results of the study suggest that the clinical laboratory constellation we used can be used as a mandatory element in the diagnosis of moderate and severe intoxication with the mentioned toxic substances.

  1. Direct Driven Permanent Magnet Synchronous Generators with Diode Rectifiers for Use in Offshore Wind Turbines

    OpenAIRE

    Reigstad, Tor Inge

    2007-01-01

    This work is focused on direct-driven permanent magnets synchronous generators (PMSG) with diode rectifiers for use in offshore wind turbines. Reactive compensation of the generator, power losses and control of the generator are studied. Configurations for power transmission to onshore point of common connection are also considered. Costs, power losses, reliability and interface with the PMSG are discussed. The purpose of the laboratory tests and simulations are to learn how a PMSG with dio...

  2. Repeated Load Permanent Deformation Behavior of Mixes With and Wihtout Modified Bituments

    Directory of Open Access Journals (Sweden)

    Imran Hafeez

    2011-01-01

    Full Text Available Premature rutting in flexible pavement structure is being observed on most of the road network of Pakistan. It initiates primarily due to uncontrolled axle loading and high ambient temperatures. NHA (National Highway Authority, Pakistan has continuously been modifying aggregate gradations and penetration grade of bitumen, without any prior investigation of the mix behaviour under the prevailing axle load and environmental conditions of the country. A comprehensive laboratory investigation was carried out on six mixes ranging from finer to coarser. Specimens were subjected to cyclic loading on UTM-5P (Universal Testing Machine to study the resistance against permanent deformation of the mixes at 25, 40 and 550C. At low temperatures and stress levels, both coarse and fine graded mixes showed less accumulated strain, whereas at higher temperatures and stress levels, coarse graded mix with PMB (Polymer Modified Bitumen showed good resistance to permanent deformation.

  3. [Quality Management and Quality Specifications of Laboratory Tests in Clinical Studies--Challenges in Pre-Analytical Processes in Clinical Laboratories].

    Science.gov (United States)

    Ishibashi, Midori

    2015-01-01

    The cost, speed, and quality are the three important factors recently indicated by the Ministry of Health, Labour and Welfare (MHLW) for the purpose of accelerating clinical studies. Based on this background, the importance of laboratory tests is increasing, especially in the evaluation of clinical study participants' entry and safety, and drug efficacy. To assure the quality of laboratory tests, providing high-quality laboratory tests is mandatory. For providing adequate quality assurance in laboratory tests, quality control in the three fields of pre-analytical, analytical, and post-analytical processes is extremely important. There are, however, no detailed written requirements concerning specimen collection, handling, preparation, storage, and shipping. Most laboratory tests for clinical studies are performed onsite in a local laboratory; however, a part of laboratory tests is done in offsite central laboratories after specimen shipping. As factors affecting laboratory tests, individual and inter-individual variations are well-known. Besides these factors, standardizing the factors of specimen collection, handling, preparation, storage, and shipping, may improve and maintain the high quality of clinical studies in general. Furthermore, the analytical method, units, and reference interval are also important factors. It is concluded that, to overcome the problems derived from pre-analytical processes, it is necessary to standardize specimen handling in a broad sense.

  4. Accuracy in HIV Rapid Testing among Laboratory and Non-laboratory Personnel in Zambia: Observations from the National HIV Proficiency Testing System.

    Directory of Open Access Journals (Sweden)

    Sheila Mwangala

    Full Text Available Despite rapid task-shifting and scale-up of HIV testing services in high HIV prevalence countries, studies evaluating accuracy remain limited. This study aimed to assess overall accuracy level and factors associated with accuracy in HIV rapid testing in Zambia.Accuracy was investigated among rural and urban HIV testing sites participating in two annual national HIV proficiency testing (PT exercises conducted in 2009 (n = 282 sites and 2010 (n = 488 sites. Testers included lay counselors, nurses, laboratory personnel and others. PT panels of five dry tube specimens (DTS were issued to testing sites by the national reference laboratory (NRL. Site accuracy level was assessed by comparison of reported results to the expected results. Non-parametric rank tests and multiple linear regression models were used to assess variation in accuracy between PT cycles and between tester groups, and to examine factors associated with accuracy respectively.Overall accuracy level was 93.1% (95% CI: 91.2-94.9 in 2009 and 96.9% (95% CI: 96.1-97.8 in 2010. Differences in accuracy were seen between the tester groups in 2009 with laboratory personnel being more accurate than non-laboratory personnel, while in 2010 no differences were seen. In both PT exercises, lay counselors and nurses had more difficulties interpreting results, with more occurrences of false-negative, false-positive and indeterminate results. Having received the standard HIV rapid testing training and adherence to the national HIV testing algorithm were positively associated with accuracy.The study showed an improvement in tester group and overall accuracy from the first PT exercise to the next. Average number of incorrect test results per 1000 tests performed was reduced from 69 to 31. Further improvement is needed, however, and the national HIV proficiency testing system seems to be an important tool in this regard, which should be continued and needs to be urgently strengthened.

  5. Laboratory procedures for waste form testing

    International Nuclear Information System (INIS)

    Mast, E.S.

    1994-01-01

    The 100 and 300 areas of the Hanford Site are included on the US Environmental Protection Agencies (EPA) National Priorities List under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). Soil washing is a treatment process that is being considered for the remediation of the soil in these areas. Contaminated soil washing fines can be mixed or blended with cementations materials to produce stable waste forms that can be used for beneficial purposes in mixed or low-level waste landfills, burial trenches, environmental restoration sites, and other applications. This process has been termed co-disposal. The Co-Disposal Treatability Study Test Plan is designed to identify a range of cement-based formulations that could be used in disposal efforts in Hanford in co-disposal applications. The purpose of this document is to provide explicit procedural information for the testing of co-disposal formulations. This plan also provides a discussion of laboratory safety and quality assurance necessary to ensure safe, reproducible testing in the laboratory

  6. Laboratory procedures for waste form testing

    Energy Technology Data Exchange (ETDEWEB)

    Mast, E.S.

    1994-09-19

    The 100 and 300 areas of the Hanford Site are included on the US Environmental Protection Agencies (EPA) National Priorities List under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). Soil washing is a treatment process that is being considered for the remediation of the soil in these areas. Contaminated soil washing fines can be mixed or blended with cementations materials to produce stable waste forms that can be used for beneficial purposes in mixed or low-level waste landfills, burial trenches, environmental restoration sites, and other applications. This process has been termed co-disposal. The Co-Disposal Treatability Study Test Plan is designed to identify a range of cement-based formulations that could be used in disposal efforts in Hanford in co-disposal applications. The purpose of this document is to provide explicit procedural information for the testing of co-disposal formulations. This plan also provides a discussion of laboratory safety and quality assurance necessary to ensure safe, reproducible testing in the laboratory.

  7. Use of laboratory test results in patient management by clinicians in Malawi.

    Science.gov (United States)

    Moyo, Kundai; Porter, Carol; Chilima, Ben; Mwenda, Reuben; Kabue, Mark; Zungu, Lutho; Sarr, Abdoulaye

    2015-11-18

    Malawi has a high burden of infectious disease. The expansion of programmes targeting these diseases requires a strong laboratory infrastructure to support both diagnosis and treatment. To assess the use of laboratory test results in patient management and to determine the requirements for improving laboratory services. A cross-sectional study was conducted in 2012 to survey practising clinicians. Two hospitals were purposively selected for observations of clinicians ordering laboratory tests. Twelve management-level key informants were interviewed. Descriptive statistics were conducted. A total of 242 clinicians were identified and 216 (89%) were interviewed. Of these, 189 (87%) reported doubting laboratory test results at some point. Clinicians most often doubted the quality of haematology (67%), followed by malaria (53%) and CD4 (22%) test results. A total of 151 (70%) clinicians reported using laboratory tests results in patient management. Use of laboratory test results at all times in patient management varied by the type of health facility ( P management. Key informants reported that the quality of laboratory services was good and useful, but that services were often unavailable. Gaps in the public laboratory system were evident. Key recommendations to enhance the use of laboratory test results in patient management were to strengthen the supply chain, reduce turn-around times, improve the test menu and improve the laboratory infrastructure.

  8. 7 CFR 58.442 - Laboratory and quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.442 Section... Service 1 Operations and Operating Procedures § 58.442 Laboratory and quality control tests. (a) Chemical... Methods or by other methods giving equivalent results. (b) Weight or volume control. Representative...

  9. Inadequate Information in Laboratory Test Requisition in a Tertiary ...

    African Journals Online (AJOL)

    Objectives: This study examined the pattern of deficiencies in the laboratory test requisition by doctors at the University of Benin Teaching Hospital, Benin City, Nigeria, with a view to suggesting strategies of reducing error rates in laboratory test requisition. Materials and Method: The study generated data through ...

  10. Are fluctuations in oil consumption permanent or transitory? Evidence from linear and nonlinear unit root tests

    International Nuclear Information System (INIS)

    Solarin, Sakiru Adebola; Lean, Hooi Hooi

    2016-01-01

    This paper examines the integration properties of the total oil consumption in 57 countries for the period of 1965–2012. A combination of new and powerful linear and nonlinear stationarity tests are employed to achieve the objectives of the study. We find that the oil consumption series in 21 countries follow a nonlinearity path while those in the other countries are linear in nature. Evidence of the presence of a unit root is found for the total oil consumption series in 38 countries while the series is stationary in the remaining 19 countries. An important insight is that the blueprints that were designed to reduce oil consumption are likely to have a permanent effect in most of the countries. - Highlights: • We examine the integration properties of total oil consumption in 57 countries. • We apply new and powerful linear and nonlinear stationarity tests. • Unit root is found in two third of the countries. • Blueprints designed to reduce oil consumption are likely to have permanent effect.

  11. To test or not to test? Laboratory support for the diagnosis of Lyme borreliosis

    DEFF Research Database (Denmark)

    Dessau, Ram B; van Dam, Alje P; Fingerle, Volker

    2018-01-01

    rational use of laboratory testing in patients with clinically suspected Lyme borreliosis. SOURCES: This is a narrative review combining various aspects of the clinical and laboratory diagnosis with an educational purpose. The literature search was based on existing systematic reviews, national...... and international guidelines and supplemented with specific citations. IMPLICATIONS: The main recommendations according to current European case definitions for Lyme borreliosis are as follows: Typical erythema migrans should be diagnosed clinically and does not require laboratory testing, the diagnosis of Lyme...

  12. Are laboratory tests always needed? Frequency and causes of laboratory overuse in a hospital setting.

    Science.gov (United States)

    Cadamuro, Janne; Gaksch, Martin; Wiedemann, Helmut; Lippi, Giuseppe; von Meyer, Alexander; Pertersmann, Astrid; Auer, Simon; Mrazek, Cornelia; Kipman, Ulrike; Felder, Thomas K; Oberkofler, Hannes; Haschke-Becher, Elisabeth

    2018-04-01

    Inappropriate utilization of laboratory resources is an increasing concern especially in high-throughput facilities. Until now, no reliable information has been published addressing to which extent laboratory results are actually used for clinical decision-making. Therefore, we aimed to close this gap using a novel retrospective approach including a survey of clinicians and nurses. We retrospectively evaluated the number of re-orders for potassium (K), lactate dehydrogenase (LD), aspartate-aminotransferase (AST), activated partial thromboplastin-time (APTT) and prothrombin-time/INR (PT/INR), after the initial order had to be cancelled due to preanalytical non-conformities. We analyzed subgroups regarding time to re-order, ward and sample priority (urgent vs. routine). Subsequently, we surveyed clinicians and nurses, asking for their estimate of the amount of failed re-orders as well as for possible reasons. From initially cancelled tests, only ~20% of K, LD, AST and ~30% of APTT and PT/INR tests were re-ordered within 24 h. 70% of the investigated clinical chemistry and 60% of coagulation tests were re-ordered one week after cancellation or not at all. Survey participants quite accurately estimated these numbers. Routine laboratory panels, short stay of out-patients, obsolete test results and avoiding additional phlebotomies were the main reasons for not re-ordering cancelled tests. Overall, 60-70% of test results in the investigated assays ordered in a high throughput laboratory are potentially inappropriate or of doubtful clinically importance. Although clinicians and nurses are aware of this situation, it is the duty of laboratory specialists to overcome overutilization in close collaboration with all involved healthcare workers. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  13. Assessment of the quality of test results from selected civil engineering material testing laboratories in Tanzania

    CSIR Research Space (South Africa)

    Mbawala, SJ

    2017-12-01

    Full Text Available Civil and geotechnical engineering material testing laboratories are expected to produce accurate and reliable test results. However, the ability of laboratories to produce accurate and reliable test results depends on many factors, among others...

  14. Towards a rational antimicrobial testing policy in the laboratory.

    Science.gov (United States)

    Banaji, N; Oommen, S

    2011-01-01

    Antimicrobial policy for prophylactic and therapeutic use of antimicrobials in a tertiary care setting has gained importance. A hospital's antimicrobial policy as laid down by its hospital infection control team needs to include inputs from the microbiology laboratory, besides the pharmacy and therapeutic committee. Therefore, it is of utmost importance that clinical microbiologists across India follow international guidelines and also take into account local settings, especially detection and presence of resistance enzymes. This article draws a framework for rational antimicrobial testing in our laboratories in tertiary care centers, from the Clinical and Laboratory Standards Institute guidelines. It does not address testing methodologies but suggests ways and means by which antimicrobial susceptibility reporting can be rendered meaningful not only to the treating physician but also to the resistance monitoring epidemiologist. It hopes to initiate some standardization in rational choice of antimicrobial testing in laboratories in the country pertaining to nonfastidious bacteria.

  15. Testing of the permanent magnet material Mn-Al-C for potential use in propulsion motors for electric vehicles

    Science.gov (United States)

    Abdelnour, Z.; Mildrun, H.; Strant, K.

    1981-01-01

    The development of Mn-Al-C permanent magnets is reviewed. The general properties of the material are discussed and put into perspective relative to alnicos and ferrites. The traction motor designer's demands of a permanent magnet for potential use in electric vehicle drives are reviewed. Tests determined magnetic design data and mechanical strength properties. Easy axis hysteresis and demagnetization curves, recoil loops and other minor loop fields were measured over a temperature range from -50 to 150 C. Hysteresis loops were also measured for three orthogonal directions (the one easy and two hard axes of magnetization). Extruded rods of three different diameters were tested. The nonuniformity of properties over the cross section of the 31 mm diameter rod was studied. Mechanical compressive and bending strength at room temperature was determined on individual samples from the 31 mm rod.

  16. Laboratory Tests of Substrate Physical Properties May Not Represent the Retention Capacity of Green Roof Substrates In Situ

    Directory of Open Access Journals (Sweden)

    Christopher Szota

    2017-11-01

    Full Text Available Green roofs can be used to reduce the volume of polluted stormwater that is generated by cities. Modelling rainfall retention is critical, but green roof water balance models often rely on the physical properties of substrates. In these models, substrate water holding capacity (WHC determines the depth of water which can be stored before runoff is generated; whereas, the permanent wilting point (PWP limits evapotranspiration. The WHC and PWP, as well as plant available water (PAW; where PAW = WHC − PWP, as determined from laboratory tests, may not truly reflect how substrates perform on green roofs. We therefore ran a simulated rainfall experiment on green roof modules to (i compare the rainfall retention of vegetated and non-vegetated substrates with different WHC and PAW, and (ii relate retention to substrate storage capacity, as calculated from laboratory measures of WHC and PAW. We found that the PAW of a substrate is a better indicator of evapotranspiration and retention when compared with WHC. However, we also found that substrates always retained less water than their calculated storage capacity would suggest, most likely being due to their high permeability. Our results indicate that using laboratory-derived measures of WHC and PAW in green roof models may be over-estimating both evapotranspiration and rainfall retention.

  17. Inter-laboratory proficiency tests to detect viral fish diseases

    DEFF Research Database (Denmark)

    Kahns, Søren; Nicolajsen, Nicole; Skall, Helle Frank

    An inter-laboratory proficiency test has ben provided by the European Community Laboratory (CRL) for Fish Diseases every year since 1996. The test is provided to all European National Reference Laboratories (NRLs) that are obliged to participate and to a limited number of non-European NRLs, making......) but also to assess their ability to differentiate other fish viruses as spring viraemia of carp virus, infectious pancreatic necrosis virus, perch rhabdovirus etc. Five coded ampoules are provided to participants containing lyophilised supernatant from infected cell cultures. The CRL collect the data...

  18. Investigation of permanent magnet machines for downhole applications: Design, prototype and testing of a flux-switching permanent magnet machine

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Anyuan

    2011-01-15

    downhole applications. Flux-switching PM (FSPM) machines, which have the PMs located on the stator and are therefore more reliable, can theoretically also exhibit high torque density and relatively high efficiency. This thesis has put an emphasis on studying this type of machine. Two FSPM machines have been investigated in detail and compared by analytical method, FEM simulation and prototype measurements. Their operating principle and important design parameters are also presented. A lumped parameter magnetic circuit model for designing a high-torque FSPM machine is newly introduced and the designed machine is verified by FEM simulations. A prototype machine with an outer diameter of 100 mm and an axial length of 200 mm is built in the laboratory and tested at room temperature. Based on that, the machine performance at an ambient temperature of 150 C is also predicted. The results show that the FSPM machine can provide a high torque density with slight compromise of efficiency and power factor. Choosing a proper machine type is significantly dependent on the application specifications. The presented results in this thesis can be used as a reference for selecting the best machine type for a specific downhole case. (Author)

  19. Laboratory tests of hydraulic fracturing and swell healing

    DEFF Research Database (Denmark)

    Thunbo, Christensen Claes; Foged, Christensen Helle; Foged, Niels

    1998-01-01

    New laboratory test set-ups and test procedures are described - for testing the formation of hydraulically induced fractures as well as the potential for subsequent fracture closurefrom the relase of a swelling potential. The main purpose with the tests is to provide information on fracturing str...

  20. Reconsolidation of salt as applied to permanent seals for the Waste Isolation Pilot Plant

    International Nuclear Information System (INIS)

    Hansen, F.D.; Callahan, G.D.; Van Sembeek, L.L.

    1993-01-01

    Reconsolidated salt is a fundamental component of the permanent seals for the Waste Isolation Pilot Plant. As regulations are currently understood and seal concepts envisioned, emplaced salt is the sole long-term seal component designed to prevent the shafts from becoming preferred pathways for rating gases or liquids. Studies under way in support of the sealing function of emplaced salt include laboratory testing of crushed salt small-scale in situ tests, constitutive modeling of crushed salt, calculations of the opening responses during operation and closure, and design practicalities including emplacement techniques. This paper briefly summarizes aspects of these efforts and key areas of future work

  1. Mobile Energy Laboratory energy-efficiency testing programs

    International Nuclear Information System (INIS)

    Parker, G.B.; Currie, J.W.

    1992-03-01

    This report summarizes energy-efficiency testing activities applying the Mobile Energy Laboratory (MEL) testing capabilities during the third and fourth quarters of fiscal year (FY) 1991. The MELs, developed by the US Department of Energy (DOE) Federal Energy Management Program (FEMP), are administered by Pacific Northwest Laboratory (PNL) and the Naval Energy and Environmental Support Activity (NEESA) for energy testing and energy conservation program support functions at federal facilities. The using agencies principally fund MEL applications, while DOE/FEMP funds program administration and capability enhancement activities. This report fulfills the requirements established in Section 8 of the MEL Use Plan (PNL-6861) for semi-annual reporting on energy-efficiency testing activities using the MEL capabilities. The MEL Use Committee, formally established in 1989, developed the MEL Use Plan and meets semi-annually to establish priorities for energy-efficient testing applications using the MEL capabilities. The MEL Use Committee is composed of one representative each of the US Department of Energy, US Army, US Air Force, US Navy, and other federal agencies

  2. Mobile Energy Laboratory energy-efficiency testing programs

    Energy Technology Data Exchange (ETDEWEB)

    Parker, G B; Currie, J W

    1992-03-01

    This report summarizes energy-efficiency testing activities applying the Mobile Energy Laboratory (MEL) testing capabilities during the third and fourth quarters of fiscal year (FY) 1991. The MELs, developed by the US Department of Energy (DOE) Federal Energy Management Program (FEMP), are administered by Pacific Northwest Laboratory (PNL) and the Naval Energy and Environmental Support Activity (NEESA) for energy testing and energy conservation program support functions at federal facilities. The using agencies principally fund MEL applications, while DOE/FEMP funds program administration and capability enhancement activities. This report fulfills the requirements established in Section 8 of the MEL Use Plan (PNL-6861) for semi-annual reporting on energy-efficiency testing activities using the MEL capabilities. The MEL Use Committee, formally established in 1989, developed the MEL Use Plan and meets semi-annually to establish priorities for energy-efficient testing applications using the MEL capabilities. The MEL Use Committee is composed of one representative each of the US Department of Energy, US Army, US Air Force, US Navy, and other federal agencies.

  3. Towards a rational antimicrobial testing policy in the laboratory

    Directory of Open Access Journals (Sweden)

    N Banaji

    2011-01-01

    Full Text Available Antimicrobial policy for prophylactic and therapeutic use of antimicrobials in a tertiary care setting has gained importance. A hospital′s antimicrobial policy as laid down by its hospital infection control team needs to include inputs from the microbiology laboratory, besides the pharmacy and therapeutic committee. Therefore, it is of utmost importance that clinical microbiologists across India follow international guidelines and also take into account local settings, especially detection and presence of resistance enzymes. This article draws a framework for rational antimicrobial testing in our laboratories in tertiary care centers, from the Clinical and Laboratory Standards Institute guidelines. It does not address testing methodologies but suggests ways and means by which antimicrobial susceptibility reporting can be rendered meaningful not only to the treating physician but also to the resistance monitoring epidemiologist. It hopes to initiate some standardization in rational choice of antimicrobial testing in laboratories in the country pertaining to nonfastidious bacteria.

  4. The Tanzania experience: clinical laboratory testing harmonization and equipment standardization at different levels of a tiered health laboratory system.

    Science.gov (United States)

    Massambu, Charles; Mwangi, Christina

    2009-06-01

    The rapid scale-up of the care and treatment programs in Tanzania during the preceding 4 years has greatly increased the demand for quality laboratory services for diagnosis of HIV and monitoring patients during antiretroviral therapy. Laboratory services were not in a position to cope with this demand owing to poor infrastructure, lack of human resources, erratic and/or lack of reagent supply and commodities, and slow manual technologies. With the limited human resources in the laboratory and the need for scaling up the care and treatment program, it became necessary to install automated equipment and train personnel for the increased volume of testing and new tests across all laboratory levels. With the numerous partners procuring equipment, the possibility of a multitude of equipment platforms with attendant challenges for procurement of reagents, maintenance of equipment, and quality assurance arose. Tanzania, therefore, had to harmonize laboratory tests and standardize laboratory equipment at different levels of the laboratory network. The process of harmonization of tests and standardization of equipment included assessment of laboratories, review of guidelines, development of a national laboratory operational plan, and stakeholder advocacy. This document outlines this process.

  5. Stochastic optimization of laboratory test workflow at metallurgical testing centers

    Directory of Open Access Journals (Sweden)

    F. Tošenovský

    2016-10-01

    Full Text Available The objective of the paper is to present a way to shorten the time required to perform laboratory tests of materials in metallurgy. The paper finds a relation between the time to perform a test of materials and the number of technicians carrying out the test. The relation can be used to optimize the number of technicians. The approach is based on probability theory, as the amount of material to be tested is unknown in advance, and uses powerful modelling techniques involving the generalized estimating equations.

  6. Quality assurance of laboratory work and clinical use of laboratory tests in general practice in norway: a survey.

    Science.gov (United States)

    Thue, Geir; Jevnaker, Marianne; Gulstad, Guri Andersen; Sandberg, Sverre

    2011-09-01

    Virtually all the general practices in Norway participate in the Norwegian Quality Improvement of Laboratory Services in Primary Care, NOKLUS. In order to assess and develop NOKLUS's services, it was decided to carry out an investigation in the largest participating group, general practices. In autumn 2008 a questionnaire was sent to all Norwegian general practices asking for feedback on different aspects of NOKLUS's main services: contact with medical laboratory technologists, sending of control materials, use and maintenance of practice-specific laboratory binders, courses, and testing of laboratory equipment. In addition, attitudes were elicited towards possible new services directed at assessing other technical equipment and clinical use of tests. Responses were received from 1290 of 1552 practices (83%). The great majority thought that the frequency of sending out control material should continue as at present, and they were pleased with the feedback reports and follow-up by the laboratory technologists in the counties. Even after many years of practical experience, there is still a need to update laboratory knowledge through visits to practices, courses, and written information. Practices also wanted quality assurance of blood pressure meters and spirometers, and many doctors wanted feedback on their use of laboratory tests. Services regarding quality assurance of point-of-care tests, guidance, and courses should be continued. Quality assurance of other technical equipment and of the doctor's clinical use of laboratory tests should be established as part of comprehensive quality assurance.

  7. The laboratory information float, time-based competition, and point-of-care testing.

    Science.gov (United States)

    Friedman, B A

    1994-01-01

    A new term, the laboratory information float, should be substituted for turnaround-time when evaluating the performance of the clinical laboratory because it includes the time necessary to make test results both available (ready to use) and accessible (easy to use) to clinicians ordering tests. The laboratory information float can be greatly reduced simply by telescoping the analytic phase of laboratory testing into the preanalytic phase. Significant costs are incurred by such a change, some of which can be reduced by developing a mobile clinical laboratory (sometimes referred to as a "lab-on-a-slab" or "rolling thunder") to transport the analytic devices directly to patient care units. The mobile clinical laboratory should be equipped with an integrated personal computer that can communicate continuously with the host laboratory information system and achieve some semblance of continuous flow processing despite test performance in point-of-care venues. Equipping clinicians with palmtop computers will allow the mobile clinician to access test results and order tests on the run. Such devices can be easily configured to operate in a passive mode, accessing relevant information automatically instead of forcing clinicians to query the laboratory information system periodically for the test results necessary to render care to their patients. The laboratory information float of the year 2,000 will surely be measured in minutes through the judicious deployment of relevant technology such as mobile clinical laboratories and palmtop computers.

  8. Automated cognitive testing of monkeys in social groups yields results comparable to individual laboratory-based testing.

    Science.gov (United States)

    Gazes, Regina Paxton; Brown, Emily Kathryn; Basile, Benjamin M; Hampton, Robert R

    2013-05-01

    Cognitive abilities likely evolved in response to specific environmental and social challenges and are therefore expected to be specialized for the life history of each species. Specialized cognitive abilities may be most readily engaged under conditions that approximate the natural environment of the species being studied. While naturalistic environments might therefore have advantages over laboratory settings for cognitive research, it is difficult to conduct certain types of cognitive tests in these settings. We implemented methods for automated cognitive testing of monkeys (Macaca mulatta) in large social groups (Field station) and compared the performance to that of laboratory-housed monkeys (Laboratory). The Field station animals shared access to four touch-screen computers in a large naturalistic social group. Each Field station subject had an RFID chip implanted in each arm for computerized identification and individualized assignment of cognitive tests. The Laboratory group was housed and tested in a typical laboratory setting, with individual access to testing computers in their home cages. Monkeys in both groups voluntarily participated at their own pace for food rewards. We evaluated performance in two visual psychophysics tests, a perceptual classification test, a transitive inference test, and a delayed matching-to-sample memory test. Despite the differences in housing, social environment, age, and sex, monkeys in the two groups performed similarly in all tests. Semi-free ranging monkeys living in complex social environments are therefore viable subjects for cognitive testing designed to take advantage of the unique affordances of naturalistic testing environments.

  9. Laboratory testing of the in-well vapor-stripping system

    International Nuclear Information System (INIS)

    Gilmore, T.J.; Francois, O.

    1996-03-01

    The Volatile organic Compounds-Arid Integrated Demonstration (VOC-Arid ID) was implemented by the US Department of Energy's (DOE's) Office of Technology Development to develop and test new technologies for the remediation of organic chemicals in the subsurface. One of the technologies being tested under the VOC-Arid ID is the in-well vapor-stripping system. The in-well vapor-stripping concept was initially proposed by researchers at Stanford University and is currently under development through a collaboration between workers at Stanford University and DOE's Pacific Northwest National Laboratory. The project to demonstrate the in-well vapor-stripping technology is divided into three phases: (1) conceptual model and computer simulation, (2) laboratory testing, and (3) field demonstration. This report provides the methods and results of the laboratory testing in which a full-scale replica was constructed and tested above ground in a test facility located at DOE's Hanford Site, Washington. The system is a remediation technology designed to preferentially extract volatile organic compounds (VOCs) from contaminated groundwater by converting them to a vapor phase

  10. Exploration of task performance tests in a physics laboratory

    Science.gov (United States)

    Liu, Dan; El Turkey, Houssein

    2017-11-01

    In this article, we investigate the implementation of task performance tests in an undergraduate physics laboratory. Two performance tests were carried out over two semesters using the task of building a DC circuit. The first implementation in Spring 2014 had certain concerns such as the privacy of students’ testing and their ‘trial and error’ attempts. These concerns were addressed in Fall 2015 through implementing a second performance test. The second implementation was administered differently but the content of the two tests was the same. We discuss the validity of both implementations and present the correlation (or lack of) between the time that students needed to complete the tests and their grades from a paper-based laboratory assessment method.

  11. Recommended procedures for performance testing of radiobioassay laboratories: Volume 1, Quality assurance

    International Nuclear Information System (INIS)

    Fenrick, H.W.; MacLellan, J.A.

    1988-11-01

    Draft American National Standards Institute (ANSI) Standard N13.30 (Performance Criteria for Radiobioassay) was developed in response to a concern expressed by the US Department of Energy and US Nuclear Regulatory Commission to help ensure that bioassay laboratories provide accurate and consistent results. The draft standard specifies the criteria for defining the procedures necessary to establish a bioassay performance-testing laboratory and program. The testing laboratory will conduct tests to evaluate the performance of service laboratories. Pacific Northwest Laboratory helped define responsibilities and develop procedures as part of an effort to evaluate the draft ANSI N13.30 performance criteria for quality assurance at bioassay laboratories. This report recommends elements of quality assurance and quality control responsibilities for the bioassay performance-testing laboratory program, including the qualification and performance of personnel and the calibration, certification, and performance of equipment. The data base and recommended records system for documenting radiobioassay performance at the service laboratories are also presented. 15 refs

  12. The performance test of NAA laboratory at radionuclide measure with low activity

    International Nuclear Information System (INIS)

    Sri Murniasih; Sukirno

    2016-01-01

    The performance test to measure the I-131 radionuclide activity has been carried out at CAST-NAA laboratory. The purpose of this activity is to know the performance of a laboratory in the testing of low radioactivity sample. The tested sample consists of the form I-131 radionuclide sources shaped thin plastic disk with a certain weight. Evaluation of laboratory performance test results carried out by the organizer of the program test appeal (PTKMR-BATAN). Evaluation results showed that testing of point source of the I-131 radionuclide with comparative method gives a good enough results with errors below 10%. The results of the performance test evaluation are useful as the external quality control to a testing method that is expected in NAA laboratory. (author)

  13. Good laboratory practices for biochemical genetic testing and newborn screening for inherited metabolic disorders.

    Science.gov (United States)

    2012-04-06

    Biochemical genetic testing and newborn screening are essential laboratory services for the screening, detection, diagnosis, and monitoring of inborn errors of metabolism or inherited metabolic disorders. Under the Clinical Laboratory Improvement Amendments of 1988 (CLIA) regulations, laboratory testing is categorized on the basis of the level of testing complexity as either waived (i.e., from routine regulatory oversight) or nonwaived testing (which includes tests of moderate and high complexity). Laboratories that perform biochemical genetic testing are required by CLIA regulations to meet the general quality systems requirements for nonwaived testing and the personnel requirements for high-complexity testing. Laboratories that perform public health newborn screening are subject to the same CLIA regulations and applicable state requirements. As the number of inherited metabolic diseases that are included in state-based newborn screening programs continues to increase, ensuring the quality of performance and delivery of testing services remains a continuous challenge not only for public health laboratories and other newborn screening facilities but also for biochemical genetic testing laboratories. To help ensure the quality of laboratory testing, CDC collaborated with the Centers for Medicare & Medicaid Services, the Food and Drug Administration, the Health Resources and Services Administration, and the National Institutes of Health to develop guidelines for laboratories to meet CLIA requirements and apply additional quality assurance measures for these areas of genetic testing. This report provides recommendations for good laboratory practices that were developed based on recommendations from the Clinical Laboratory Improvement Advisory Committee, with additional input from the Secretary's Advisory Committee on Genetics, Health, and Society; the Secretary's Advisory Committee on Heritable Disorders in Newborns and Children; and representatives of newborn

  14. Quality assurance practices in Europe: a survey of molecular genetic testing laboratories

    Science.gov (United States)

    Berwouts, Sarah; Fanning, Katrina; Morris, Michael A; Barton, David E; Dequeker, Elisabeth

    2012-01-01

    In the 2000s, a number of initiatives were taken internationally to improve quality in genetic testing services. To contribute to and update the limited literature available related to this topic, we surveyed 910 human molecular genetic testing laboratories, of which 291 (32%) from 29 European countries responded. The majority of laboratories were in the public sector (81%), affiliated with a university hospital (60%). Only a minority of laboratories was accredited (23%), and 26% was certified. A total of 22% of laboratories did not participate in external quality assessment (EQA) and 28% did not use reference materials (RMs). The main motivations given for accreditation were to improve laboratory profile (85%) and national recognition (84%). Nearly all respondents (95%) would prefer working in an accredited laboratory. In accredited laboratories, participation in EQA (Pquality assurance (Pquality implementation score (QIS), we showed that accredited laboratories (average score 92) comply better than certified laboratories (average score 69, Pquality indicators. We conclude that quality practices vary widely in European genetic testing laboratories. This leads to a potentially dangerous situation in which the quality of genetic testing is not consistently assured. PMID:22739339

  15. Trends in laboratory test volumes for Medicare Part B reimbursements, 2000-2010.

    Science.gov (United States)

    Shahangian, Shahram; Alspach, Todd D; Astles, J Rex; Yesupriya, Ajay; Dettwyler, William K

    2014-02-01

    Changes in reimbursements for clinical laboratory testing may help us assess the effect of various variables, such as testing recommendations, market forces, changes in testing technology, and changes in clinical or laboratory practices, and provide information that can influence health care and public health policy decisions. To date, however, there has been no report, to our knowledge, of longitudinal trends in national laboratory test use. To evaluate Medicare Part B-reimbursed volumes of selected laboratory tests per 10,000 enrollees from 2000 through 2010. Laboratory test reimbursement volumes per 10,000 enrollees in Medicare Part B were obtained from the Centers for Medicare & Medicaid Services (Baltimore, Maryland). The ratio of the most recent (2010) reimbursed test volume per 10,000 Medicare enrollees, divided by the oldest data (usually 2000) during this decade, called the volume ratio, was used to measure trends in test reimbursement. Laboratory tests with a reimbursement claim frequency of at least 10 per 10,000 Medicare enrollees in 2010 were selected, provided there was more than a 50% change in test reimbursement volume during the 2000-2010 decade. We combined the reimbursed test volumes for the few tests that were listed under more than one code in the Current Procedural Terminology (American Medical Association, Chicago, Illinois). A 2-sided Poisson regression, adjusted for potential overdispersion, was used to determine P values for the trend; trends were considered significant at P reimbursement volumes were electrolytes, digoxin, carbamazepine, phenytoin, and lithium, with volume ratios ranging from 0.27 to 0.64 (P reimbursement volumes were meprobamate, opiates, methadone, phencyclidine, amphetamines, cocaine, and vitamin D, with volume ratios ranging from 83 to 1510 (P reimbursement volumes increased for most of the selected tests, other tests exhibited statistically significant downward trends in annual reimbursement volumes. The observed

  16. Antiphospholipid Syndrome Laboratory Testing and Diagnostic Strategies

    Science.gov (United States)

    Ortel, Thomas L.

    2016-01-01

    The Antiphospholipid Syndrome (APS) is diagnosed in patients with recurrent thromboembolic events and/or pregnancy loss in the presence of persistent laboratory evidence for antiphospholipid antibodies. Diagnostic tests for the detection of antiphospholipid antibodies include laboratory assays that detect anticardiolipin antibodies, lupus anticoagulants, and anti-β2-glycoprotein I antibodies. These assays have their origins beginning more than sixty years ago, with the identification of the biologic false positive test for syphilis, the observation of ‘circulating anticoagulants’ in certain patients with systemic lupus erythematosus, the identification of cardiolipin as a key component in the serologic test for syphilis, and the recognition and characterization of a ‘cofactor’ for antibody binding to phospholipids. Although these assays have been used clinically for many years, there are still problems with the accurate diagnosis of patients with this syndrome. For example, lupus anticoagulant testing can be difficult to interpret in patients receiving anticoagulant therapy, but most patients with a thromboembolic event will already be anticoagulated before the decision to perform the tests has been made. In addition to understanding limitations of the assays, clinicians also need to be aware of which patients should be tested and not obtain testing on patients unlikely to have APS. New tests and diagnostic strategies are in various stages of development and should help improve our ability to accurately diagnose this important clinical disorder. PMID:22473619

  17. Recommended procedures for performance testing of radiobioassay laboratories: Volume 2, In vitro samples

    International Nuclear Information System (INIS)

    Fenrick, H.W.; MacLellan, J.A.

    1988-11-01

    Draft American National Standards Institute (ANSI) Standard N13.30 (Performance Criteria for Radiobioassay) was developed for the US Department of Energy and the US Nuclear Regulatory Commission to help ensure that bioassay laboratories provide accurate and consistent results. The draft standard specifies the criteria for defining the procedures necessary to establish a bioassay performance-testing laboratory and program. The bioassay testing laboratory will conduct tests to evaluate the performance of service laboratories. Pacific Northwest Laboratory helped develop testing procedures as part of an effort to evaluate the performance criteria by testing the existing measurement capabilities of various bioassay laboratories. This report recommends guidelines for the preparation, handling, storage, distribution, shipping, and documentation of in vitro test samples (artificial urine and fecal matter) for indirect bioassay. The data base and recommended records system for documenting radiobioassay performance at the service laboratories are also presented. 8 refs., 3 tabs

  18. New perspectives about molecular arrangement of primary and permanent dentin

    Energy Technology Data Exchange (ETDEWEB)

    Sanches Borges, Ana Flavia [Department of Dental Materials at Piracicaba Dental School, State University of Campinas, Piracicaba, SP (Brazil); Andrade Bitar, Renata [Biomedical Engineering, Valley of Paraiba University (UNIVAP) (Brazil); Kantovitz, Kamila Rosamilia [Department of Pediatric Dentistry at Piracicaba Dental School, State University of Campinas, Piracicaba, SP (Brazil); Bortollazo Correr, Americo [Department of Dental Materials at Piracicaba Dental School, State University of Campinas, Piracicaba, SP (Brazil); Martin, Airton Abrahao [Biomedical Engineering Post Graduation, Valley of Paraiba University (UNIVAP) (Brazil); Puppin-Rontani, Regina Maria [Department of Pediatric Dentistry at Piracicaba Dental School, State University of Campinas, Piracicaba, SP (Brazil)], E-mail: rmpuppin@fop.unicamp.br

    2007-12-30

    The dentin quality of primary and permanent teeth was inspected by Fourier transformed Raman spectroscopy (FT-Raman); scanning electron microscopy/energy-dispersive spectroscopy (SEM/EDS) and hardness test. Middle dentin of crowns were reached by carbide bur abrading providing a uniform smear layer. Phosphoric acid was applied in order to simulate the etching of total etching adhesive systems. The groups were (n = 10): G1 (primary dentin smear layer); G2 (35% phosphoric acid etched primary dentin); G3 (permanent dentin smear layer); G4 (35% phosphoric acid etched permanent dentin). FT-Raman results were subjected to cluster analysis. SEM/EDS were made in order to add the data obtained by FT-Raman. The hardness data were subjected to ANOVA and Tukey test. FT-Raman showed differences among groups, either to organic or inorganic content. For the organic content, primary and permanent dentin became similar after the etching; conversely, the inorganic content showed differences for the two substrates. Hardness test showed no significant differences between primary and permanent dentin, before or after etching, but the etching decreased these values. The mineral content arrangement of primary dentin is different from permanent dentin, independently of the etching. The substrate type did no influence the hardness, but the etching decreased it.

  19. Evaluation of three oil spill laboratory dispersant effectiveness tests

    International Nuclear Information System (INIS)

    Sullivan, D.; Farlow, J.; Sahatjian, K.A.

    1993-01-01

    Chemical dispersants can be used to reduce the interfacial tension of floating oil slicks so that the oils disperse more rapidly into the water column and thus pose less of a threat to shorelines, birds, and marine mammals. The laboratory test currently specified in federal regulations to measure dispersant effectiveness is not especially easy or inexpensive, and generates a rather large quantity of oily waste water. This paper describes the results of an effort by the EPA to identify a more suitable laboratory dispersant effectiveness test. EPA evaluated three laboratory methods: the Revised Standard Dispersant Effectiveness Test currently used (and required by regulation) in the United States, the swirling flask test (developed by Environment Canada), and the IFP-dilution test (used in france and other European countries). Six test oils and three dispersants were evaluated; dispersants were applied to the oil at an average 1:10 ratio (dispersant to oil) for each of the three laboratory methods. Screening efforts were used to focus on the most appropriate oil/dispersant combination for detailed study. A screening criterion was established that required a combination that gave at least 20% effectiveness results. The selected combination turned out to be Prudhoe Bay crude oil and the dispersant Corexit 9527. This combination was also most likely to be encountered in US coastal waters. The EPA evaluation concluded that the three tests gave similar precision results, but that the swirling flask test was fastest, cheapest, simplest, and required least operator skill. Further, EPA is considering conducting the dispersant effectiveness test itself, rather than having data submitted by a dispersant manufacturer, and establishing an acceptability criterion (45% efficiency) which would have to be met before a dispersant could be placed on the Product Schedule of the National Contingency Plan (NCP)

  20. Radiographic testing at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Bossi, R.H.

    1982-01-01

    Radiographic testing is a nondestructive inspection technique which uses penetrating radiation. The Nondestructive Evaluation (NDE) Section at Lawrence Livermore National Laboratory has a broad spectrum of equipment and techniques for radiographic testing. These resources include low-energy vacuum systems, low- and mid-energy cabinet and cell radiographic systems, high-energy linear accelerators, portable x-ray machines and radioisotopes for radiographic inspections. For diagnostic testing the NDE Section also has real-time and flash radiographic equipment

  1. 42 CFR 493.1453 - Condition: Laboratories performing high complexity testing; clinical consultant.

    Science.gov (United States)

    2010-10-01

    ... Condition: Laboratories performing high complexity testing; clinical consultant. The laboratory must have a... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Laboratories performing high complexity testing; clinical consultant. 493.1453 Section 493.1453 Public Health CENTERS FOR MEDICARE & MEDICAID...

  2. Test plan for demonstration of Rapid Transuranic Monitoring Laboratory

    International Nuclear Information System (INIS)

    McIsaac, C.V.; Sill, C.W.; Gehrke, R.J.; Killian, E.W.; Watts, K.D.

    1993-06-01

    This plan describes tests to demonstrate the capability of the Rapid Transuranic Monitoring Laboratory (RTML) to monitor airborne alpha-emitting radionuclides and analyze soil, smear, and filter samples for alpha- and gamma-emitting radionuclides under field conditions. The RTML will be tested during June 1993 at a site adjacent to the Cold Test Pit at the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory. Measurement systems installed in the RTML that will be demonstrated include two large-area ionization chamber alpha spectrometers, an x-ray/gamma-ray spectrometer, and four alpha continuous air monitors. Test objectives, requirements for data quality, experimental apparatus and procedures, and safety and logistics issues are described

  3. AUDILAB: a knowledge-based quality audit simulator for testing laboratories.

    Science.gov (United States)

    Brai, A; Garnerin, P

    1997-05-01

    In order to obtain an accreditation, a laboratory must be prepared to provide a point-by-point check of various activities against the chosen reference standard, both from a general point of view and in relation to details of application. This paper describes AUDILAB, a computerized simulator accessible by network, able to provide testing laboratories with realistic quality audits performed in a customized way. AUDILAB establishes a detailed list of strengths (compliance with corresponding requirements of established standards) and weaknesses (improvements needed for laboratory's accreditation). The standard used by AUDILAB is the EN 45001 "General criteria for the operation of testing laboratories". A preliminary validation has already been completed. AUDILAB became operational in September 1993.

  4. Accreditation of testing laboratories in CNEA (National Atomic Energy Commission)

    International Nuclear Information System (INIS)

    Piacquadio, N.H.; Casa, V.A.; Palacios, T.A.

    1993-01-01

    The recognition of the technical capability of a testing laboratory is carried out by Laboratory Accreditation Bodies as the result of a satisfactory evaluation and the systematic follow up of the certified qualification. In Argentina the creation of a National Center for the Accreditation of Testing Laboratories, as a first step to assess a National Accreditation System is currently projected. CNEA, as an institution involved in technological projects and in the development and production of goods and services, has adopted since a long time ago quality assurance criteria. One of their requirements is the qualification of laboratories. Due to the lack of a national system, a Committee for the Qualification of Laboratories was created jointly by the Research and Development and Nuclear Fuel Cycle Areas with the responsibility of planning and management of the system evaluation and the certification of the quality of laboratories. The experience in the above mentioned topics is described in this paper. (author)

  5. Approaches to quality management and accreditation in a genetic testing laboratory

    Science.gov (United States)

    Berwouts, Sarah; Morris, Michael A; Dequeker, Elisabeth

    2010-01-01

    Medical laboratories, and specifically genetic testing laboratories, provide vital medical services to different clients: clinicians requesting a test, patients from whom the sample was collected, public health and medical-legal instances, referral laboratories and authoritative bodies. All expect results that are accurate and obtained in an efficient and effective manner, within a suitable time frame and at acceptable cost. There are different ways of achieving the end results, but compliance with International Organization for Standardization (ISO) 15189, the international standard for the accreditation of medical laboratories, is becoming progressively accepted as the optimal approach to assuring quality in medical testing. We present recommendations and strategies designed to aid genetic testing laboratories with the implementation of a quality management system, including key aspects such as document control, external quality assessment, internal quality control, internal audit, management review, validation, as well as managing the human side of change. The focus is on pragmatic approaches to attain the levels of quality management and quality assurance required for accreditation according to ISO 15189, within the context of genetic testing. Attention is also given to implementing efficient and effective quality improvement. PMID:20720559

  6. Immediate needs for MQA testing at state secondary calibration laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Cline, R. [Radiation Instrument Calibration Laboratory, Springfield, IL (United States)

    1993-12-31

    The Calibration Laboratory attempts to provide services that satisfy the needs and requests for a variety of customers. New needs and requests have resulted in calibration of instrumentation outside the original laboratory designs. These tasks require several changes at the laboratory and a need for new support services, especially measurement quality assurance (MQA). The MQA tests are gamma (Cs-137) below 0.5 mrem (5{mu}Sv) per hour and x-ray kVp. Modification to the current gamma (Cs-137) MQA test is recommended because lower intensity fields are commonly measured.

  7. Immediate needs for MQA testing at state secondary calibration laboratories

    International Nuclear Information System (INIS)

    Cline, R.

    1993-01-01

    The Calibration Laboratory attempts to provide services that satisfy the needs and requests for a variety of customers. New needs and requests have resulted in calibration of instrumentation outside the original laboratory designs. These tasks require several changes at the laboratory and a need for new support services, especially measurement quality assurance (MQA). The MQA tests are gamma (Cs-137) below 0.5 mrem (5μSv) per hour and x-ray kVp. Modification to the current gamma (Cs-137) MQA test is recommended because lower intensity fields are commonly measured

  8. Hydrogen stability of SmCo5 permanent magnet

    International Nuclear Information System (INIS)

    Lukin, A.; Rabinovich, Y.; Bala, H.

    2001-01-01

    The present work has been performed with purpose to determine the level of hydrogen stability of sintered SmCo 5 permanent magnets by means of accelerated tests, to study the effect of hydrogen on the magnetic and mechanical properties of the permanent magnets and to establish the criteria of hydrogenation level and the activation energy of this process. In addition, the effect of hydrogen on the properties of sintered SmCo 5 permanent magnets in specific conditions of exploitation and storage durability of instruments was studied

  9. Development of New, Low-Head Hydropower Turbine - Modeling & Laboratory Test DE-EE0005426

    Energy Technology Data Exchange (ETDEWEB)

    Krouse, Wayne [Hydro Green Energy, Westmont, IL (United States)

    2014-12-05

    Hydro Green Energy, LLC (HGE) will complete the design, fabrication and laboratory testing of a scaled, vertically stackable, low-head hydropower turbine called the Modular Bulb Turbine (MBT). HGE will also complete a summary report that includes the laboratory testing results and analysis of the tests. Project Goals: Design, model and test modular bulb turbine for installation in numerous HGE low-head hydropower projects at non-powered USACE dams. Project Results: The sub-scale prototype was tested successfully at a leading US hydraulic laboratory. Laboratory data results agreed well with predicted results from numerical modeling.

  10. Hydrogen Field Test Standard: Laboratory and Field Performance

    Science.gov (United States)

    Pope, Jodie G.; Wright, John D.

    2015-01-01

    The National Institute of Standards and Technology (NIST) developed a prototype field test standard (FTS) that incorporates three test methods that could be used by state weights and measures inspectors to periodically verify the accuracy of retail hydrogen dispensers, much as gasoline dispensers are tested today. The three field test methods are: 1) gravimetric, 2) Pressure, Volume, Temperature (PVT), and 3) master meter. The FTS was tested in NIST's Transient Flow Facility with helium gas and in the field at a hydrogen dispenser location. All three methods agree within 0.57 % and 1.53 % for all test drafts of helium gas in the laboratory setting and of hydrogen gas in the field, respectively. The time required to perform six test drafts is similar for all three methods, ranging from 6 h for the gravimetric and master meter methods to 8 h for the PVT method. The laboratory tests show that 1) it is critical to wait for thermal equilibrium to achieve density measurements in the FTS that meet the desired uncertainty requirements for the PVT and master meter methods; in general, we found a wait time of 20 minutes introduces errors methods, respectively and 2) buoyancy corrections are important for the lowest uncertainty gravimetric measurements. The field tests show that sensor drift can become a largest component of uncertainty that is not present in the laboratory setting. The scale was calibrated after it was set up at the field location. Checks of the calibration throughout testing showed drift of 0.031 %. Calibration of the master meter and the pressure sensors prior to travel to the field location and upon return showed significant drifts in their calibrations; 0.14 % and up to 1.7 %, respectively. This highlights the need for better sensor selection and/or more robust sensor testing prior to putting into field service. All three test methods are capable of being successfully performed in the field and give equivalent answers if proper sensors without drift are

  11. Biometric identification devices -- Laboratory testing vs. real life

    International Nuclear Information System (INIS)

    Ahrens, J.S.

    1997-01-01

    For over fifteen years Sandia National Laboratories has been involved in laboratory testing of biometric identification devices. The key concept of biometric identification devices is the ability for the system to identify some unique aspect of the individual rather than some object a person may be carrying or some password they are required to know. Tests were conducted to verify manufacturer's performance claims, to determine strengths/weaknesses of devices, and to determine devices that meet the US Department of energy's needs. However, during recent field installation, significantly different performance was observed than was predicted by laboratory tests. Although most people using the device believed it operated adequately, the performance observed was over an order of magnitude worse than predicted. The search for reasons behind this gap between the predicted and the actual performance has revealed many possible contributing factors. As engineers, the most valuable lesson to be learned from this experience is the value of scientists and engineers with (1) common sense, (2) knowledge of human behavior, (3) the ability to observe the real world, and (4) the capability to realize the significant differences between controlled experiments and actual installations

  12. Hydramite II screening tests of potential bremsstrahlung converter debris shield materials

    International Nuclear Information System (INIS)

    Reedy, E.D. Jr.; Hedemann, M.A.; Stark, M.A.

    1986-03-01

    Results of a brief test series aimed at screening a number of potential bremsstrahlung converter debris shield materials are reported. These tests were run on Sandia National Laboratories' Hydramite II accelerator using a diode configuration which produces a pinched electron beam. The materials tested include: (1) laminated Kevlar 49/polyester and E-glass/polyester composites, (2) a low density laminated Kevlar 49 composite, and (3) two types of through-the-thickness reinforced Kevlar 49 composites. As expected, tests using laminated Kevlar 49/polyester shields showed that shield permanent set (i.e., permanent deflection) increased with increasing tantalum conversion foil thickness and decreased with increasing shield thickness. The through-the-thickness reinforced composites developed localized, but severe, back surface damage. The laminated composites displayed little back surface damage, although extensive internal matrix cracking and ply delaminations were generated. Roughly the same degree of permanent set was produced in shields made from the low density Kevlar 49 composite and the Kevlar 49/polyester. The E-glass reinforced shields exhibited relatively low levels of permanent set

  13. The testing effect for mediator final test cues and related final test cues in online and laboratory experiments.

    Science.gov (United States)

    Coppens, Leonora C; Verkoeijen, Peter P J L; Bouwmeester, Samantha; Rikers, Remy M J P

    2016-05-31

    The testing effect is the finding that information that is retrieved during learning is more often correctly retrieved on a final test than information that is restudied. According to the semantic mediator hypothesis the testing effect arises because retrieval practice of cue-target pairs (mother-child) activates semantically related mediators (father) more than restudying. Hence, the mediator-target (father-child) association should be stronger for retrieved than restudied pairs. Indeed, Carpenter (2011) found a larger testing effect when participants received mediators (father) than when they received target-related words (birth) as final test cues. The present study started as an attempt to test an alternative account of Carpenter's results. However, it turned into a series of conceptual (Experiment 1) and direct (Experiment 2 and 3) replications conducted with online samples. The results of these online replications were compared with those of similar existing laboratory experiments through small-scale meta-analyses. The results showed that (1) the magnitude of the raw mediator testing effect advantage is comparable for online and laboratory experiments, (2) in both online and laboratory experiments the magnitude of the raw mediator testing effect advantage is smaller than in Carpenter's original experiment, and (3) the testing effect for related cues varies considerably between online experiments. The variability in the testing effect for related cues in online experiments could point toward moderators of the related cue short-term testing effect. The raw mediator testing effect advantage is smaller than in Carpenter's original experiment.

  14. Pirm wastes: permanent isolation in rock-forming minerals

    International Nuclear Information System (INIS)

    Smyth, J.R.; Vidale, R.J.; Charles, R.W.

    1977-01-01

    The most practical system for permanent isolation of radioactive wastes in granitic and pelitic environments may be one which specifically tailors the waste form to the environment. This is true because if recrystallization of the waste form takes place within the half-lives of the hazardous radionuclides, it is likely to be the rate-controlling step for release of these nuclides to the ground-water system. The object of the proposed waste-form research at Los Alamos Scintific Laboratory (LASL) is to define a phase assemblage which will minimize chemical reaction with natural fluids in a granitic or pelitic environment. All natural granites contain trace amounts of all fission product elements (except Tc) and many contain minor amounts of these elements as major components of certain accessory phases. Observation of the geochemistry of fission-product elements has led to the identification of the natural minerals as target phases for research. A proposal is made to experimentally determine the amounts of fission product elements which can stably be incorporated into the phases listed below and to determine the leachability of the assemblage this produced using fluids typical of the proposed environments at the Nevada Test Site. This approach to waste isolation satisfies the following requirements: (1) It minimizes chemical reaction with the environment (i.e., recrystallization) which is likely to be the rate-controlling step for release of radionuclides to groundwater; (2) Waste loading (hence temperature) can be easily varied by dilution with material mined from the disposal site; (3) No physical container is required; (4) No maintenance is required (permanent); (5) The environment acts as a containment buffer. It is proposed that such wastes be termed PIRM wastes, for Permanent Isolation in Rock-forming Minerals

  15. Obtaining patient test results from clinical laboratories: a survey of state law for pharmacists.

    Science.gov (United States)

    Witry, Matthew J; Doucette, William R

    2009-01-01

    To identify states with laws that restrict to whom clinical laboratories may release copies of laboratory test results and to describe how these laws may affect pharmacists' ability to obtain patient laboratory test results. Researchers examined state statutes and administrative codes for all 50 states and the District of Columbia at the University of Iowa Law Library between June and July 2007. Researchers also consulted with lawyers, state Clinical Laboratory Improvement Amendments officers, and law librarians. Laws relating to the study objective were analyzed. 34 jurisdictions do not restrict the release of laboratory test results, while 17 states have laws that restrict to whom clinical laboratories can send copies of test results. In these states, pharmacists will have to use alternative sources, such as physician offices, to obtain test results. Pharmacists must consider state law before requesting copies of laboratory test results from clinical laboratories. This may be an issue that state pharmacy associations can address to increase pharmacist access to important patient information.

  16. Development of a Laboratory Test Procedure to Evaluate Tack Coat Performance

    OpenAIRE

    YILDIRIM, Yetkin; SMIT, André de Fortier; KORKMAZ, Armagan

    2014-01-01

    A laboratory testing procedure is presented, the results of which may be used for determining the best combination of tack coat type, mixture type, and application rate to be applied in the field for optimum performance. Tack coat related performance results were determined from Hamburg wheel tracking and simple shear tests on laboratory prepared specimens. This study was undertaken to evaluate the shear strength performance of tack coats under laboratory-controlled conditions. The ...

  17. Evaluation of permanent deformation characteristics of unmodified and Polyethylene Terephthalate modified asphalt mixtures using dynamic creep test

    International Nuclear Information System (INIS)

    Baghaee Moghaddam, Taher; Soltani, Mehrtash; Karim, Mohamed Rehan

    2014-01-01

    Highlights: • Waste PET was utilized as modifier in asphalt mixture. • Deformation characteristics of asphalt mixtures were assessed. • Dynamic creep test was conducted at different temperatures and stress levels. • Permanent deformation models were introduced. - Abstract: One of the major types of plastics that can be found in Municipal Solid Waste (MSW) is Polyethylene Terephthalate (PET) which is a non-biodegradable semi-crystalline thermoplastic polymer, and is considered as polyester material. Generating large amount of waste PET, mainly as bottles, would cause environmental hazards by disposing in landfills. This paper aims to evaluate effects of utilizing waste PET flakes as modifier in asphalt mixture as an alternative solution to overcome the potential risks arise from producing large amount of waste PET as well as evaluating the deformation characteristics of unmodified and PET modified asphalt mixtures. To achieve this aim, different percentages of PET were designated for this investigation, namely: 0%, 0.2%, 0.4%, 0.6%, 0.8% and 1% by weight of aggregate particles, and dynamic creep test was performed at different stress levels (300 kPa and 400 kPa) and temperatures (10 °C, 25 °C and 40 °C). Consequently, Zhou three-stage model was developed. The results showed that permanent deformation characteristics of asphalt mixture were considerably improved by utilization of PET modification, when the permanent strain was remarkably decreased in PET modified mixture compared to the conventional mixture at all stress levels and temperatures. Besides, based on Zhou model, it was concluded that elastic and visco-elastic properties of asphalt mixture were improved by application of PET modification

  18. Interference by pralidoxime (PAM) salts in clinical laboratory tests.

    Science.gov (United States)

    Nagase, Sumika; Kohguchi, Katsunori; Tohyama, Kaoru; Watanabe, Mikio; Iwatani, Yoshinori

    2013-02-01

    Drugs sometimes alter the results of clinical laboratory tests. We examined the effects of pralidoxime (PAM) salts, a medicine used to treat organophosphorus poisoning, on clinical laboratory test results for the first time. The effects of PAM salts on glucose (GLU) measurements were examined using a point-of-care testing (POCT) meter, four self-monitoring of blood glucose (SMBG) meters, and two biochemical autoanalyzers. The effects of PAM salts on other clinical tests were also evaluated. The addition of PAM iodide or potassium iodide, but not of PAM chloride or potassium chloride, to blood samples increased the GLU values measured by one POCT meter and 4 SMBG meters using the enzyme electrode (hydrogen peroxidase or oxygen electrode) method. On the other hand, PAM iodide or PAM chloride, but not KI or KCl, affected the values measured at 340 nm by an autoanalyzer using absorption spectrophotometry in 8 of 14 clinical laboratory tests. The absorption spectrum of PAM changed from 294 to 338 nm due to the reaction between PAM and the alkaline buffer, a component of the measuring reagents. PAM iodide increases the GLU values measured by the enzyme electrode method, and PAM salts affected the values measured at 340 nm by absorption spectrophotometry in many other clinical test items. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Proficiency testing schemes as a quality rating in industrial hygiene laboratories

    Directory of Open Access Journals (Sweden)

    Marek Dobecki

    2016-04-01

    Full Text Available This publication presents the principles of organization, implementation, assessment and exploitation of proficiency testing results in the work environmental laboratory based on basic requirements included in standard PN-EN ISO/IEC 17043 and ISO 13528. The basis for the proper functioning of the laboratory is to use and observe the basic requirements for the competence to carry out the tests and the guidelines on ensuring reliable and accurate results, specified e.g., according to the guidelines described in the standard PN-EN ISO/IEC 17043. The confirmation of the laboratory competence is the obtained accreditation. To obtain this certificate several conditions, including proficiency testing (PT should be met. The main aspects of this paper is to show the role of proficiency testing in the process of assuring a properly functioning quality system in the laboratory. The accreditation requirements, the types of proficiency testing schemes, methods of statistical analysis and interpretation of results are also discussed by the authors. Med Pr 2016;67(2:267–283

  20. Duplicate laboratory test reduction using a clinical decision support tool.

    Science.gov (United States)

    Procop, Gary W; Yerian, Lisa M; Wyllie, Robert; Harrison, A Marc; Kottke-Marchant, Kandice

    2014-05-01

    Duplicate laboratory tests that are unwarranted increase unnecessary phlebotomy, which contributes to iatrogenic anemia, decreased patient satisfaction, and increased health care costs. We employed a clinical decision support tool (CDST) to block unnecessary duplicate test orders during the computerized physician order entry (CPOE) process. We assessed laboratory cost savings after 2 years and searched for untoward patient events associated with this intervention. This CDST blocked 11,790 unnecessary duplicate test orders in these 2 years, which resulted in a cost savings of $183,586. There were no untoward effects reported associated with this intervention. The movement to CPOE affords real-time interaction between the laboratory and the physician through CDSTs that signal duplicate orders. These interactions save health care dollars and should also increase patient satisfaction and well-being.

  1. Comparison of Rapid Malaria Test and Laboratory Microscopy ...

    African Journals Online (AJOL)

    Michael Horsfall

    ABSTRACT: Blood samples collected from 272 volunteers in two communities of Bayelsa State in the Niger. Delta area were investigated for falciparum malaria parasite using the rapid test based on the detection of soluble antigen and laboratory microscopy test. The data showed that out of the 272 samples collected, ...

  2. Mars Science Laboratory Rover System Thermal Test

    Science.gov (United States)

    Novak, Keith S.; Kempenaar, Joshua E.; Liu, Yuanming; Bhandari, Pradeep; Dudik, Brenda A.

    2012-01-01

    On November 26, 2011, NASA launched a large (900 kg) rover as part of the Mars Science Laboratory (MSL) mission to Mars. The MSL rover is scheduled to land on Mars on August 5, 2012. Prior to launch, the Rover was successfully operated in simulated mission extreme environments during a 16-day long Rover System Thermal Test (STT). This paper describes the MSL Rover STT, test planning, test execution, test results, thermal model correlation and flight predictions. The rover was tested in the JPL 25-Foot Diameter Space Simulator Facility at the Jet Propulsion Laboratory (JPL). The Rover operated in simulated Cruise (vacuum) and Mars Surface environments (8 Torr nitrogen gas) with mission extreme hot and cold boundary conditions. A Xenon lamp solar simulator was used to impose simulated solar loads on the rover during a bounding hot case and during a simulated Mars diurnal test case. All thermal hardware was exercised and performed nominally. The Rover Heat Rejection System, a liquid-phase fluid loop used to transport heat in and out of the electronics boxes inside the rover chassis, performed better than predicted. Steady state and transient data were collected to allow correlation of analytical thermal models. These thermal models were subsequently used to predict rover thermal performance for the MSL Gale Crater landing site. Models predict that critical hardware temperatures will be maintained within allowable flight limits over the entire 669 Sol surface mission.

  3. Chemical Pathology Laboratory Tests in Pregnancy | Bolarin ...

    African Journals Online (AJOL)

    Thus, chemical pathology laboratory investigative test results during normal healthy pregnancy show significant differences from the normal reference intervals or ranges (i.e. non-pregnant woman's reference intervals or ranges) thereby causing misinterpretation as inappropriate or odd. This wrong interpretation of the ...

  4. Application of flexible scope in large testing laboratories

    Directory of Open Access Journals (Sweden)

    Carina Di Candia

    2011-04-01

    Full Text Available According as the international definition of Flexible Scope, a laboratory must demonstrate face with the accreditation body that it has the knowledge, experience and competence to work within the full range of its flexible scope, as well as possessing suitable laboratory environments and equipment. The laboratory must also demonstrate that it has a management system in place that can control its proposed approach while continuing to comply with the requirements of ISO 17025:2005. In case of UKAS (Unites Kingdom Accreditation Service, prior to offering accreditation for flexible scope they must have a high degree of confidence that the staff are technically competent and that the management system controlling certain key processes as development, review, validation and authorization.LATU apply these requirements since 2004 as "Unified Tests". Until this date, LATU was doing the same type of tests in different materials departments using different equipment, personal, and testing quality control. In order to that were defined cross disciplinary groups to analyze this topic approaching in personal competence and quality control tests improvement, and resource's decrease. For example, LATU has the Unified Test Tensile Strength accredited by UKAS in: corrugated and solid fiberboard, paper board, linerboard, cork plugs, plastic bags, plastic sheeting, paper, woven fabrics, plastic woven bags and woven plastic. As a result of the Unified Tests was generated a general unified manage procedure with unified criteria's, responsibilities and actions. Was written a unique testing procedure not only with the actual flexible scope and the flexibilities limits but also the compliance requirements of ISO 17025 and the accreditations body methodology. We could decrease the amount of documentation to control. Was defined the methodology and implemented periodicaly internal inter comparisons between departments in order to valid the unified tests and has a unique

  5. System Quality Management in Software Testing Laboratory that Chooses Accreditation

    Directory of Open Access Journals (Sweden)

    Yanet Brito R.

    2013-12-01

    Full Text Available The evaluation of software products will reach full maturity when executed by the scheme and provides third party certification. For the validity of the certification, the independent laboratory must be accredited for that function, using internationally recognized standards. This brings with it a challenge for the Industrial Laboratory Testing Software (LIPS, responsible for testing the products developed in Cuban Software Industry, define strategies that will permit it to offer services with a high level of quality. Therefore it is necessary to establish a system of quality management according to NC-ISO/IEC 17025: 2006 to continuously improve the operational capacity and technical competence of the laboratory, with a view to future accreditation of tests performed. This article discusses the process defined in the LIPS for the implementation of a Management System of Quality, from the current standards and trends, as a necessary step to opt for the accreditation of the tests performed.

  6. Use of the National Committee for Clinical Laboratory Standards Guidelines for Disk Diffusion Susceptibility Testing in New York State Laboratories

    Science.gov (United States)

    Kiehlbauch, Julia A.; Hannett, George E.; Salfinger, Max; Archinal, Wendy; Monserrat, Catherine; Carlyn, Cynthia

    2000-01-01

    Accurate antimicrobial susceptibility testing is vital for patient care and surveillance of emerging antimicrobial resistance. The National Committee for Clinical Laboratory Standards (NCCLS) outlines generally agreed upon guidelines for reliable and reproducible results. In January 1997 we surveyed 320 laboratories participating in the New York State Clinical Evaluation Program for General Bacteriology proficiency testing. Our survey addressed compliance with NCCLS susceptibility testing guidelines for bacterial species designated a problem (Staphylococcus aureus and Enterococcus species) or fastidious (Streptococcus pneumoniae, Haemophilus influenzae, and Neisseria gonorrhoeae) organism. Specifically, we assessed compliance with guidelines for inoculum preparation, medium choice, number of disks per plate, and incubation conditions for disk diffusion tests. We also included length of incubation for S. aureus and Enterococcus species. We found overall compliance with the five characteristics listed above in 80 of 153 responding laboratories (50.6%) for S. aureus and 72 of 151 (47.7%) laboratories for Enterococcus species. The most common problem was an incubation time shortened to less than 24 h. Overall compliance with the first four characteristics was reported by 92 of 221 (41.6%) laboratories for S. pneumoniae, 49 of 163 (30.1%) laboratories for H. influenzae, and 11 of 77 (14.3%) laboratories for N. gonorrhoeae. Laboratories varied from NCCLS guidelines by placing an excess number of disks per plate. Laboratories also reported using alternative media for Enterococcus species, N. gonorrhoeae, and H. influenzae. This study demonstrates a need for education among clinical laboratories to increase compliance with NCCLS guidelines. PMID:10970381

  7. Laboratory test for ice adhesion strength using commercial instrumentation.

    Science.gov (United States)

    Wang, Chenyu; Zhang, Wei; Siva, Adarsh; Tiea, Daniel; Wynne, Kenneth J

    2014-01-21

    A laboratory test method for evaluating ice adhesion has been developed employing a commercially available instrument normally used for dynamic mechanical analysis (TA RSA-III). This is the first laboratory ice adhesion test that does not require a custom-built apparatus. The upper grip range of ∼10 mm is an enabling feature that is essential for the test. The method involves removal of an ice cylinder from a polymer coating with a probe and the determination of peak removal force (Ps). To validate the test method, the strength of ice adhesion was determined for a prototypical glassy polymer, poly(methyl methacrylate). The distance of the probe from the PMMA surface has been identified as a critical variable for Ps. The new test provides a readily available platform for investigating fundamental surface characteristics affecting ice adhesion. In addition to the ice release test, PMMA coatings were characterized using DSC, DCA, and TM-AFM.

  8. Pilot instrumentation of a Superpave test section at the Kansas Accelerated Testing laboratory

    Science.gov (United States)

    2003-04-01

    Two Superpave test sections were constructed at the Kansas Accelerated Testing Laboratory (K-ATL) with 12.5 mm (2 in) nominal maximum size Superpave mixture (SM-2A) with varying percentages (15 and 30 percent) of river sand. A 150 kN (34 kip) tandem ...

  9. Utility of laboratory testing for the diagnosis of Hymenoptera venom allergy.

    Science.gov (United States)

    Vachová, Martina; Panzner, Petr; Malkusová, Ivana; Hanzlíková, Jana; Vlas, Tomáš

    2016-05-01

    A diagnosis of Hymenoptera venom allergy is based on clinical history and the results of skin tests and/or laboratory methods. To analyze the utility of available laboratory tests in diagnosing Hymenoptera venom allergy. Ninety-five patients with Hymenoptera venom allergy with a history of bee (35) or wasp (60) anaphylactic sting reaction and positive skin test with bee or wasp venom were included in this analysis. Specific immunoglobulin E (to bee venom extract, wasp venom extract, available recombinant molecules, and a basophil activation test with venom extracts were assessed in all the patients. Test sensitivity and specificity were calculated by using standard threshold values; then, receiver operating characteristic curve analysis was performed to compute optimal threshold values. Also, statistical analysis of the utility of different combinations of laboratory tests was performed. The optimal threshold values were revealed to be the following: 1.0 kIU/L for bee venom extract (sensitivity, 97.14%; specificity, 100%), 0.35 kIU/L for rApi m 1 (sensitivity, 68.57%; specificity, 100%), 1.22 kIU/L for wasp venom extract (sensitivity, 88.33%; specificity, 95.45%), 0.7 kIU/L for rVes v 5 (sensitivity, 86.67%; specificity, 95.45%), 1.0 kIU/L for rVes v 1 (sensitivity, 56.67%; specificity, 95.45%), 6.5% for basophil activation test with bee venom extract (sensitivity, 80%; specificity, 95.45%), and 4.5% for basophil activation test with wasp venom extract (sensitivity, 91.53%; specificity, 95.45%). The best test combinations were found to be the following: bee venom extract plus rApi m 1 (sensitivity, 97.14%; specificity, 95.45%) in bee and either wasp venom extract plus rVes v 5, or rVes v 5 plus rVes v 1 (both sensitivity, 98.33%; specificity, 95.45%) in patients with wasp venom allergy. Our analysis confirmed that currently used laboratory tests represent effective tools in diagnosing Hymenoptera venom allergy. Moreover, our probabilistic approach offered another

  10. Educational ultrasound nondestructive testing laboratory.

    Science.gov (United States)

    Genis, Vladimir; Zagorski, Michael

    2008-09-01

    The ultrasound nondestructive evaluation (NDE) of materials course was developed for applied engineering technology students at Drexel University's Goodwin College of Professional Studies. This three-credit, hands-on laboratory course consists of two parts: the first part with an emphasis on the foundations of NDE, and the second part during which ultrasound NDE techniques are utilized in the evaluation of parts and materials. NDE applications are presented and applied through real-life problems, including calibration and use of the latest ultrasonic testing instrumentation. The students learn engineering and physical principles of measurements of sound velocity in different materials, attenuation coefficients, material thickness, and location and dimensions of discontinuities in various materials, such as holes, cracks, and flaws. The work in the laboratory enhances the fundamentals taught during classroom sessions. This course will ultimately result in improvements in the educational process ["The greater expectations," national panel report, http://www.greaterexpectations.org (last viewed February, 2008); R. M. Felder and R. Brent "The intellectual development of Science and Engineering Students. Part 2: Teaching to promote growth," J. Eng. Educ. 93, 279-291 (2004)] since industry is becoming increasingly reliant on the effective application of NDE technology and the demand on NDE specialists is increasing. NDE curriculum was designed to fulfill levels I and II NDE in theory and training requirements, according to American Society for Nondestructive Testing, OH, Recommended Practice No. SNT-TC-1A (2006).

  11. Tunable high-gradient permanent magnet quadrupoles

    CERN Document Server

    Shepherd, B J A; Marks, N; Collomb, N A; Stokes, D G; Modena, M; Struik, M; Bartalesi, A

    2014-01-01

    A novel type of highly tunable permanent magnet (PM) based quadrupole has been designed by the ZEPTO collaboration. A prototype of the design (ZEPTO-Q1), intended to match the specification for the CLIC Drive Beam Decelerator, was built and magnetically measured at Daresbury Laboratory and CERN. The prototype utilises two pairs of PMs which move in opposite directions along a single vertical axis to produce a quadrupole gradient variable between 15 and 60 T/m. The prototype meets CLIC's challenging specification in terms of the strength and tunability of the magnet.

  12. Package testing capabilities at the Pacific Northwest Laboratory

    International Nuclear Information System (INIS)

    Taylor, J.M.

    1993-01-01

    The purpose of this paper is to describe the package testing capabilities at the Pacific Northwest Laboratory (PNL). In the past all of the package testing that was performed at PNL was done on prototype or mocked up radioactive material packaging. Presently, we are developing the capability to perform testing on non-radioactive material packaging. The testing on the non-radioactive material packaging will be done to satisfy the new performance oriented packaging requirements (DOT Docket HM-181, 1991). This paper describes the equipment used to perform the performance oriented packaging tests and also describes some testing capability for testing radioactive material packaging

  13. The quality of veterinary in-clinic and reference laboratory biochemical testing.

    Science.gov (United States)

    Rishniw, Mark; Pion, Paul D; Maher, Tammy

    2012-03-01

    Although evaluation of biochemical analytes in blood is common in veterinary practice, studies assessing the global quality of veterinary in-clinic and reference laboratory testing have not been reported. The aim of this study was to assess the quality of biochemical testing in veterinary laboratories using results obtained from analyses of 3 levels of assayed quality control materials over 5 days. Quality was assessed by comparison of calculated total error with quality requirements, determination of sigma metrics, use of a quality goal index to determine factors contributing to poor performance, and agreement between in-clinic and reference laboratory mean results. The suitability of in-clinic and reference laboratory instruments for statistical quality control was determined using adaptations from the computerized program, EZRules3. Reference laboratories were able to achieve desirable quality requirements more frequently than in-clinic laboratories. Across all 3 materials, > 50% of in-clinic analyzers achieved a sigma metric ≥ 6.0 for measurement of 2 analytes, whereas > 50% of reference laboratory analyzers achieved a sigma metric ≥ 6.0 for measurement of 6 analytes. Expanded uncertainty of measurement and ± total allowable error resulted in the highest mean percentages of analytes demonstrating agreement between in-clinic and reference laboratories. Owing to marked variation in bias and coefficient of variation between analyzers of the same and different types, the percentages of analytes suitable for statistical quality control varied widely. These findings reflect the current state-of-the-art with regard to in-clinic and reference laboratory analyzer performance and provide a baseline for future evaluations of the quality of veterinary laboratory testing. © 2012 American Society for Veterinary Clinical Pathology.

  14. Biointrusion test plan for the Permanent Isolation Surface Barrier Prototype

    International Nuclear Information System (INIS)

    Link, S.O.; Cadwell, L.L.; Brandt, C.A.; Downs, J.L.; Rossi, R.E.; Gee, G.W.

    1994-04-01

    This document provides a testing and monitoring plan for the biological component of the prototype barrier slated for construction at the Hanford Site. The prototype barrier is an aboveground structure engineered to demonstrate the basic features of an earthen cover system. It is designed to permanently isolate waste from the biosphere. The features of the barrier include multiple layers of soil and rock materials and a low-permeability asphalt sublayer. The surface of the barrier consists of silt loam soil, covered with plants. The barrier sides are reinforced with rock or coarse earthen-fill to protect against wind and water erosion. The sublayers inhibit plant and animal intrusion and percolation of water. A series of tests will be conducted on the prototype barrier over the next several years to evaluate barrier performance under extreme climatic conditions. Plants and animals will play a significant role in the hydrologic and water and wind erosion characteristics of the prototype barrier. Studies on the biological component of the prototype barrier will include work on the initial revegetation of the surface, continued monitoring of the developing plant community, rooting depth and dispersion in the context of biointrusion potential, the role of plants in the hydrology of the surface and toe regions of the barrier, the role of plants in stabilizing the surface against water and wind erosion, and the role of burrowing animals in the hydrology and water and wind erosion of the barrier

  15. Laboratory test of an APS-based sun sensor prototype

    Science.gov (United States)

    Rufino, Giancarlo; Perrotta, Alessandro; Grassi, Michele

    2017-11-01

    This paper deals with design and prototype development of an Active Pixel Sensor - based miniature sun sensor and a laboratory facility for its indoor test and calibration. The miniature sun sensor is described and the laboratory test facility is presented in detail. The major focus of the paper is on tests and calibration of the sensor. Two different calibration functions have been adopted. They are based, respectively, on a geometrical model, which has required least-squares optimisation of system physical parameters estimates, and on neural networks. Calibration results are presented for the above solutions, showing that accuracy in the order of 0.01° has been achieved. Neural calibration functions have attained better performance thanks to their intrinsic auto-adaptive structure.

  16. Performance testing of UK personal dosimetry laboratories

    CERN Document Server

    Marshall, T O

    1985-01-01

    The proposed Ionising Radiations Regulations will require all UK personal dosimetry laboratories that monitor classified personnel to be approved for personal dosimetry by the Health and Safety Executive. It is suggested that these approvals should be based on general and supplementary criteria published by the British Calibration Service (BCS) for laboratory approval for the provision of personal dosimetry services. These criteria specify certain qualitative requirements and also indicate the need for regular tests of performance to be carried out to ensure constancy of dosimetric standards. This report concerns the latter. The status of the BCS criteria is discussed and the need for additional documents to cover new techniques and some modifications to existing documents is indicated. A means is described by which the technical performance of laboratories, concerned with personal monitoring for external radiations, can be assessed, both initially and ongoing. The costs to establish the scheme and operate it...

  17. Laced permanent magnet quadrupole drift tube magnets

    International Nuclear Information System (INIS)

    Feinberg, B.; Behrsing, G.U.; Halbach, K.; Marks, J.S.; Morrison, M.E.; Nelson, D.H.

    1988-10-01

    A laced permanent magnet quadrupole drift tube magnet has been constructed for a proof-of-principle test. The magnet is a conventional tape-wound quadrupole electromagnet, using iron pole- pieces, with the addition of permanent magnet material (neodymium iron) between the poles to reduce the effects of saturation. The iron is preloaded with magnetic flux generated by the permanent magnet material, resulting in an asymmetrical saturation curve. Since the polarity of the quadrupole magnets in a drift tube linac is not reversed we can take advantage of this asymmetrical saturation to provide greater focusing strength. The magnet configuration has been optimized and the vanadium permendur poles needed in a conventional quadrupole have been replaced with iron poles. The use of permanent magnet material has allowed us to increase the focusing strength of the magnet by about 20% over that of a conventional tape-wound quadrupole. Comparisons will be made between this magnet and the conventional tape-wound quadrupole. 3 refs., 5 figs

  18. Text Messaging Improves Participation in Laboratory Testing in Adolescent Liver Transplant Patients.

    Science.gov (United States)

    McKenzie, Rebecca B; Berquist, William E; Foley, Megan A; Park, K T; Windsheimer, Jered E; Litt, Iris F

    In solid organ transplant patients, non-participation in all aspects of the medical regimen is a prevalent problem associated with adverse consequences particularly in the adolescent and young adult (AYA) age group. This study is the first to evaluate the feasibility, utility and impact of a text messaging (TM) intervention to improve participation in laboratory testing in adolescent liver transplant patients. AYA patients, aged 12 to 21 years, were recruited for a prospective pilot trial evaluating a TM intervention delivered over a 1-year period. The intervention involved automated TM reminders with feedback administered according to a prescribed laboratory testing frequency. Participation rate in laboratory testing after the intervention was compared to the year prior. Patient responses and feedback by text and survey were used to assess feasibility, acceptability and use of the intervention. Forty-two patients were recruited and 33 patients remained enrolled for the study duration. Recipients of the TM intervention demonstrated a significant improvement in participation rate in laboratory testing from 58% to 78% (Prate was also significantly higher than in non-intervention controls (P=.003). There was a high acceptability, response rate and a significant correlation with reported versus actual completion of laboratory tests by TM. TM reminders significantly improved participation in laboratory testing in AYA liver transplant patients. The intervention demonstrated feasibility, acceptability, and use with a high proportion of patients who engaged in and perceived a benefit from using this technology.

  19. 40 CFR Appendix II to Part 1054 - Duty Cycles for Laboratory Testing

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Duty Cycles for Laboratory Testing II.... 1054, App. II Appendix II to Part 1054—Duty Cycles for Laboratory Testing (a) Test handheld engines with the following steady-state duty cycle: G3 mode No. Engine speed a Torque(percent) b Weighting...

  20. Standards on the permanence of recording materials

    Science.gov (United States)

    Adelstein, Peter Z.

    1996-02-01

    The permanence of recording materials is dependent upon many factors, and these differ for photographic materials, magnetic tape and optical disks. Photographic permanence is affected by the (1) stability of the material, (2) the photographic processing and (3) the storage conditions. American National Standards on the material and the processing have been published for different types of film and standard test methods have been established for color film. The third feature of photographic permanence is the storage requirements and these have been established for photographic film, prints and plates. Standardization on the permanence of electronic recording materials is more complicated. As with photographic materials, stability is dependent upon (1) the material itself and (2) the storage environment. In addition, retention of the necessary (3) hardware and (4) software is also a prerequisite. American National Standards activity in these areas has been underway for the past six years. A test method for the material which determines the life expectancy of CD-ROMs has been standardized. The problems of determining the expected life of magnetic tape have been more formidable but the critical physical properties have been determined. A specification for the storage environment of magnetic tape has been finalized and one on the storage of optical disks is being worked on. Critical but unsolved problems are the obsolescence of both the hardware and the software necessary to read digital images.

  1. The laboratory test utilization management toolbox.

    Science.gov (United States)

    Baird, Geoffrey

    2014-01-01

    Efficiently managing laboratory test utilization requires both ensuring adequate utilization of needed tests in some patients and discouraging superfluous tests in other patients. After the difficult clinical decision is made to define the patients that do and do not need a test, a wealth of interventions are available to the clinician and laboratorian to help guide appropriate utilization. These interventions are collectively referred to here as the utilization management toolbox. Experience has shown that some tools in the toolbox are weak and other are strong, and that tools are most effective when many are used simultaneously. While the outcomes of utilization management studies are not always as concrete as may be desired, what data is available in the literature indicate that strong utilization management interventions are safe and effective measures to improve patient health and reduce waste in an era of increasing financial pressure.

  2. DTU PMU Laboratory Development - Testing and Validation

    OpenAIRE

    Garcia-Valle, Rodrigo; Yang, Guang-Ya; Martin, Kenneth E.; Nielsen, Arne Hejde; Østergaard, Jacob

    2010-01-01

    This is a report of the results of phasor measurement unit (PMU) laboratory development and testing done at the Centre for Electric Technology (CET), Technical University of Denmark (DTU). Analysis of the PMU performance first required the development of tools to convert the DTU PMU data into IEEE standard, and the validation is done for the DTU-PMU via a validated commercial PMU. The commercial PMU has been tested from the authors' previous efforts, where the response can be expected to foll...

  3. The permanent process

    DEFF Research Database (Denmark)

    Møller, Jesper; McCullagh, Peter

    We extend the boson process first to a large class of Cox processes and second an even larger class of infinitely divisible point processes. Density and moment results are studied in detail. These results are obtained in closed form as weighted permanents, so the extension is called a permanent...... process. Temporal extensions and a particularly tractable case of the permanent process are also studied. Extensions of the ferminon process along similar lines, leading to so-called determinant processes, are discussed at the end. While the permanent process is attractive, the determinant process...

  4. PENGUKURAN PERMANENT EARNINGS PADA HUBUNGAN DENGAN KEBIJAKAN DIVIDEND PERUSAHAAN : REVIEW PENELITIAN

    Directory of Open Access Journals (Sweden)

    Wahyu Manuhara Putra

    2016-02-01

    Full Text Available Corporate earnings divided into a permanent component of earnings and transitory earnings will be very useful in estimating the future value of the company, that will be useful in decision making stock return. Be more relevant for investors and financial analysts in analyzing the earnings based on the permanent and transitory earnings. On permanent earnings will be more focused to get the gain from investments. One focus of research is based on this component is to test the relationship with the earnings dividend payment policy. Based on several studies obtained different results concerning the relationship with the permanent earnings dividend policy. Research that focuses on permanent earnings using two approaches to determine the accuracy of the proxy of permanent earnings. Determination of permanent earnings through the stock price and the latter by using the accounting profit.

  5. A test of object permanence in a new-world monkey species, cotton top tamarins (Saguinus oedipus).

    Science.gov (United States)

    Neiworth, Julie J; Steinmark, Eric; Basile, Benjamin M; Wonders, Ryann; Steely, Frances; DeHart, Catherine

    2003-03-01

    Cotton top tamarins were tested in visible and invisible displacement tasks in a method similar to that used elsewhere to test squirrel monkeys and orangutans. All subjects performed at levels significantly above chance on visible ( n=8) and invisible ( n=7) displacements, wherein the tasks included tests of the perseverance error, tests of memory in double and triple displacements, and "catch" trials that tested for the use of the experimenter's hand as a cue for the correct cup. Performance on all nine tasks was significantly higher than chance level selection of cups, and tasks using visible displacements generated more accurate performance than tasks using invisible displacements. Performance was not accounted for by a practice effect based on exposure to successive tasks. Results suggest that tamarins possess stage 6 object permanence capabilities, and that in a situation involving brief exposure to tasks and foraging opportunities, tracking objects' movements and responding more flexibly are abilities expressed readily by the tamarins.

  6. Model Testing - Bringing the Ocean into the Laboratory

    DEFF Research Database (Denmark)

    Aage, Christian

    2000-01-01

    Hydrodynamic model testing, the principle of bringing the ocean into the laboratory to study the behaviour of the ocean itself and the response of man-made structures in the ocean in reduced scale, has been known for centuries. Due to an insufficient understanding of the physics involved, however......, the early model tests often gave incomplete or directly misleading results.This keynote lecture deals with some of the possibilities and problems within the field of hydrodynamic and hydraulic model testing....

  7. Performance testing of UK personal dosimetry laboratories

    International Nuclear Information System (INIS)

    Marshall, T.O.

    1985-01-01

    The proposed Ionising Radiations Regulations will require all UK personal dosimetry laboratories that monitor classified personnel to be approved for personal dosimetry by the Health and Safety Executive. It is suggested that these approvals should be based on general and supplementary criteria published by the British Calibration Service (BCS) for laboratory approval for the provision of personal dosimetry services. These criteria specify certain qualitative requirements and also indicate the need for regular tests of performance to be carried out to ensure constancy of dosimetric standards. This report concerns the latter. The status of the BCS criteria is discussed and the need for additional documents to cover new techniques and some modifications to existing documents is indicated. A means is described by which the technical performance of laboratories, concerned with personal monitoring for external radiations, can be assessed, both initially and ongoing. The costs to establish the scheme and operate it are also estimated. (author)

  8. A Novel 100 kW Power Hardware-in-the-Loop Emulation Test Bench for Permanent Magnet Synchronous Machines with Nonlinear Magnetics

    OpenAIRE

    Schmitt, Alexander; Richter, Jan; Gommeringer, Mario; Wersal, Thomas; Braun, Michael

    2016-01-01

    This paper presents a high dynamic power hardware-inthe-loop (PHIL) emulation test bench to mimic arbitrary permanent magnet synchronous machines with nonlinear magnetics. The proposed PHIL test bench is composed of a high performance real-time simulation system to calculate the machine behaviour and a seven level modular multiphase multilevel converter to emulate the power flow of the virtual machine. The PHIL test bench is parametrized for an automotive synchronous machine and controlled by...

  9. Wind Structural Testing Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — This facility provides office space for industry researchers, experimental laboratories, computer facilities for analytical work, and space for assembling components...

  10. Quality of HIV laboratory testing in Tanzania: a situation analysis ...

    African Journals Online (AJOL)

    December 2004 to February 2005 in 12 laboratories which were conveniently selected to represent all the zones of Tanzania. The questionnaires comprised of questions on laboratory particulars, internal and external quality control for HIV testing and quality control of reagents. Source and level of customer satisfaction of ...

  11. Sand characterization by combined centrifuge and laboratory tests

    OpenAIRE

    GAUDIN, C; SCHNAID, F; GARNIER, J

    2005-01-01

    The purpose of this paper is to evaluate new methods of interpretation of in situ tests in sand from correlations established from centrifuge and laboratory data. Emphasis is given to methods that are based on the combination of measurements from independent tests, such as the ratio of the elastic stiffness to ultimate strenght and the ratio of cone resistance and limit pressure. For that purpose, a series of centrifuge tests using a cone penetrometer and a cone pressuremeter was carried out ...

  12. Development of a hybrid bearing using permanent magnets and piezoelectric actuators

    International Nuclear Information System (INIS)

    Park, Jung-Ho; Ham, Young-Bog; Yun, So-Nam; Lee, Hu-Seung

    2010-01-01

    In this study, a hybrid magnetic bearing with permanent magnets and piezoelectric actuators is investigated. First, in this study, a novel concept in which piezoelectric actuators are used to compensate for low stiffness and damping resulting from the unstable characteristics of a passive magnetic bearing using only permanent magnets is proposed. Secondly, the permanent magnets are optimally arranged through an electromagnetic field analysis. Then, the driving amplifier unit and a prototype radial bearing using the proposed concept are fabricated. Finally, basic characteristics, such as the results of an impact test and a rotational runout test with constant speed are investigated and discussed, and experiments using PID control method are conducted.

  13. MagLev Cobra: Test Facilities and Operational Experiments

    Science.gov (United States)

    Sotelo, G. G.; Dias, D. H. J. N.; de Oliveira, R. A. H.; Ferreira, A. C.; De Andrade, R., Jr.; Stephan, R. M.

    2014-05-01

    The superconducting MagLev technology for transportation systems is becoming mature due to the research and developing effort of recent years. The Brazilian project, named MagLev-Cobra, started in 1998. It has the goal of developing a superconducting levitation vehicle for urban areas. The adopted levitation technology is based on the diamagnetic and the flux pinning properties of YBa2Cu3O7-δ (YBCO) bulk blocks in the interaction with Nd-Fe-B permanent magnets. A laboratory test facility with permanent magnet guideway, linear induction motor and one vehicle module is been built to investigate its operation. The MagLev-Cobra project state of the art is presented in the present paper, describing some construction details of the new test line with 200 m.

  14. 49 CFR 40.99 - How long does the laboratory retain specimens after testing?

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false How long does the laboratory retain specimens after testing? 40.99 Section 40.99 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.99 How...

  15. Antifungal susceptibility testing method for resource constrained laboratories

    Directory of Open Access Journals (Sweden)

    Khan S

    2006-01-01

    Full Text Available Purpose: In resource-constrained laboratories of developing countries determination of antifungal susceptibility testing by NCCLS/CLSI method is not always feasible. We describe herein a simple yet comparable method for antifungal susceptibility testing. Methods: Reference MICs of 72 fungal isolates including two quality control strains were determined by NCCLS/CLSI methods against fluconazole, itraconazole, voriconazole, amphotericin B and cancidas. Dermatophytes were also tested against terbinafine. Subsequently, on selection of optimum conditions, MIC was determined for all the fungal isolates by semisolid antifungal agar susceptibility method in Brain heart infusion broth supplemented with 0.5% agar (BHIA without oil overlay and results were compared with those obtained by reference NCCLS/CLSI methods. Results: Comparable results were obtained by NCCLS/CLSI and semisolid agar susceptibility (SAAS methods against quality control strains. MICs for 72 isolates did not differ by more than one dilution for all drugs by SAAS. Conclusions: SAAS using BHIA without oil overlay provides a simple and reproducible method for obtaining MICs against yeast, filamentous fungi and dermatophytes in resource-constrained laboratories.

  16. Laboratory Tests in the Development of WaveCat

    Directory of Open Access Journals (Sweden)

    James Allen

    2016-12-01

    Full Text Available WaveCat, a novel overtopping Wave Energy Converter, was tested with the aim of determining its performance under different sea states, establishing a starting point for optimisation of the device, numerical model validation and proof-of-concept for the control systems. The tests were carried out at a 1:30 scale in the Ocean Basin of the COAST Laboratory at University of Plymouth. A state-of-the-art control system was implemented, and overtopping rates and device motions were recorded alongside the wave field. It was observed that power generation is dependent on both the wave height and period, with smaller periods tending to produce greater overtopping rates, and therefore greater power generation, for the same wave height. Due to time constraints in the laboratory, only one configuration of draft/freeboard was tested; with this configuration, overtopping occurred under significant wave heights of 0.083 m or more, corresponding to 2.5 m or more in prototype values. These experimental results form the basis for future development and optimisation of WaveCat.

  17. Permanent deformation and deflection relationship from pavement condition assessment

    Directory of Open Access Journals (Sweden)

    Fabricio Leiva-Villacorta

    2017-07-01

    Full Text Available The development of permanent deformation in flexible pavements has been a research topic for several decades. Currently there are models included in the structural design of pavements that can predict this type of failure. However, the variables required for the prediction of this distress are complex or difficult to obtain in the field, making its application in pavement evaluation also difficult. Measurement of the deflection of pavement structures by means of non-destructive testing is a technique used to assess the condition of the pavement. This research study seeks to correlate data from deflections of the pavement surface with probable permanent deformation in time. In addition, prediction of the remaining life of the pavement structure using a specified criterion is also analyzed. In order to accomplish these objectives, data acquired from 4 different full scale accelerated pavement test tracks was used to develop a permanent deformation model as a function of deflection, load repetitions and pavement layer thickness. The developed model considered a time series model that incorporates an Auto-regressive parameter of order 1. The proposed model presents an advantage over currently available models because it reduces the required parameters to predict the permanent deformation and/or remaining life in the structure and because these variables can be easily found and updated in a pavement management system. Keywords: HVS, Permanent deformation, Deflections, APT, Time series, Instrumentation

  18. Workplace bullying a risk for permanent employees.

    Science.gov (United States)

    Keuskamp, Dominic; Ziersch, Anna M; Baum, Fran E; Lamontagne, Anthony D

    2012-04-01

    We tested the hypothesis that the risk of experiencing workplace bullying was greater for those employed on casual contracts compared to permanent or ongoing employees. A cross-sectional population-based telephone survey was conducted in South Australia in 2009. Employment arrangements were classified by self-report into four categories: permanent, casual, fixed-term and self-employed. Self-report of workplace bullying was modelled using multiple logistic regression in relation to employment arrangement, controlling for sex, age, working hours, years in job, occupational skill level, marital status and a proxy for socioeconomic status. Workplace bullying was reported by 174 respondents (15.2%). Risk of workplace bullying was higher for being in a professional occupation, having a university education and being separated, divorced or widowed, but did not vary significantly by sex, age or job tenure. In adjusted multivariate logistic regression models, casual workers were significantly less likely than workers on permanent or fixed-term contracts to report bullying. Those separated, divorced or widowed had higher odds of reporting bullying than married, de facto or never-married workers. Contrary to expectation, workplace bullying was more often reported by permanent than casual employees. It may represent an exposure pathway not previously linked with the more idealised permanent employment arrangement. A finer understanding of psycho-social hazards across all employment arrangements is needed, with equal attention to the hazards associated with permanent as well as casual employment. © 2012 The Authors. ANZJPH © 2012 Public Health Association of Australia.

  19. Contributory Factors Related to Permanent Deformation of Hot Asphalt Mixtures

    Directory of Open Access Journals (Sweden)

    Alaa Husein Abd

    2017-03-01

    Full Text Available Permanent deformation (Rutting of asphalt pavements which appears in many roads in Iraq, have caused a major impact on pavement performance by reducing the useful service life of pavement and creating services hazards for highway users. The main objective of this research is investigating the effect of some contributory factors related to permanent deformation of asphalt concrete mixture. To meet the objectives of this research, available local materials are used including asphalt binder, aggregates, mineral filler and modified asphalt binder. The Superpave mix design system was adopted with varying volumetric compositions. The Superpave Gyratory Compactor was used to compact 24 asphalt concrete cylindrical specimens. To collect the required data and investigate the development of permanent deformation in asphalt concrete under repeated loadings, Wheel-Tracking apparatus has been used in a factorial testing program during which 44 slab samples; with dimensions of 400×300×50 mm; were tested to simulate . actual pavement. Based on wheel-tracking test results, it has been concluded that increasing the compaction temperature from 110 to 150ºC caused a decreasing in permanent deformation by 20.5 and 15.6 percent for coarse and fine gradation control asphalt mixtures respectively. While the permanent deformation decreased about 21.3 percent when the compaction temperature is increased from 110 to 150ºC for coarse gradation asphalt mixtures modified with styrene butadiene styrene SBS with 3 percent by asphalt binder weight.

  20. Novel ocean energy permanent magnet linear generator buoy

    Energy Technology Data Exchange (ETDEWEB)

    Rhinefrank, K.; Agamloh, E.B.; Jouanne, A. von; Wallace, A.K.; Prudell, J.; Kimble, K.; Aills, J.; Schmidt, E.; Schacher, A. [School of Electrical Engineering and Computer Science, Oregon State University, Corvallis, OR 97331-3211 (United States); Chan, P.; Sweeny, B. [Department of Mechanical Engineering, Oregon State University, Corvallis, OR 97331-3211 (United States)

    2006-07-15

    This paper describes the research, design, construction and prototype testing process of a novel ocean energy direct drive permanent magnet linear generator buoy. The buoy employs the vertical component of the motion of ocean waves to power a linear generator. The generator consists of a permanent magnet field system (mounted on the central translator shaft) and an armature, in which the power is generated (mounted on the buoy). The translator shaft is anchored to the sea floor, and the buoy/floater moves armature coils relative to the permanent magnet translator to induce voltages. The electrical and mechanical structures of the buoy generator are provided, along with performance characteristics, including voltage, current and developed power. (author)

  1. Results of Laboratory Testing of Advanced Power Strips

    Energy Technology Data Exchange (ETDEWEB)

    Earle, L. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Sparn, B. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2012-08-01

    Presented at the ACEEE Summer Study on Energy Efficiency in Buildings on August 12-17, 2012, this presentation reports on laboratory tests of 20 currently available advanced power strip products, which reduce wasteful electricity use of miscellaneous electric loads in buildings.

  2. Design and construction of the SSCL magnet test laboratory cryogenic systems

    International Nuclear Information System (INIS)

    Freeman, M.A.; Kobel, T.A.

    1992-01-01

    The intent of this document is to provide a brief summary of the execution, by Process Systems International, Inc. (PSI), of the Design and Construction of the SSCL Magnet Test Laboratory Cryogenic Systems. This $30 million project requires the expenditure of over 200,000 manhours and the procurement of $17 million in materials within a two year period. SSC magnets will be performance tested at the Magnet Test Laboratory (MTL) and the Accelerator System String Test (ASST) facility under conditions simulating the environment of the SSC main ring. The cryogenic system consists of test stands (five for MTL, one for ASST) and the associated equipment including cryogenic storage, purification, thermal conditioning, and helium refrigeration necessary to support the test program

  3. Essure Permanent Birth Control

    Science.gov (United States)

    ... Prosthetics Essure Permanent Birth Control Essure Permanent Birth Control Share Tweet Linkedin Pin it More sharing options ... Print Essure is a a permanently implanted birth control device for women (female sterilization). Implantation of Essure ...

  4. Interlaboratory test comparison among Environmental Radioactivity Laboratories using the ISO/IUPAC/AOAC Protocol

    International Nuclear Information System (INIS)

    Romero, L.; Ramos, L.; Salas, R.

    1998-01-01

    World-wide acceptance of results from radiochemical analyses requires reliable, traceable and comparable measurements to SI units, particularly when data sets generated by laboratories are to contribute to evaluation of data from environmental pollution research and monitoring programmes. The Spanish Nuclear Safety Council (CSN) organizes in collaboration with CIEMAT periodical interlaboratory test comparisons for environmental radioactivity laboratories aiming to provide them with the necessary means to asses the quality of their results. This paper presents data from the most recent exercise which, for the first time, was evaluated following the procedure recommended in the ISO/IUPAC/AOAC Harmonized Protocol for the proficiency testing of analytical laboratories (1). The test sample was a Reference Material provided by the IAEA-AQCS, a lake sediment containing the following radionuclides: k-40, Ra-226, Ac-228, Cs-137, Sr-90, Pu-(239+240). The results of the proficiency test were computed for the 28 participating laboratories using the z-score approach, the evaluation of the exercises is presented in the paper. The use of a z-score classification has demonstrated to provide laboratories with a more objective means of assessing and demonstrating the reliability of the data they are producing. Analytical proficiency of the participating laboratories has been found to be satisfactory in 57 to 100 percent of cases. (1)- The International harmonized protocol for the proficiency testing of (chemical) analytical laboratories. Pure and Appl. Chem. Vol. 65, n 9, pp. 2123-2144, 1993 IUPAC. GB (Author) 3 refs

  5. Safety in the Chemical Laboratory: Tested Disposal Methods for Chemical Wastes from Academic Laboratories.

    Science.gov (United States)

    Armour, M. A.; And Others

    1985-01-01

    Describes procedures for disposing of dichromate cleaning solution, picric acid, organic azides, oxalic acid, chemical spills, and hydroperoxides in ethers and alkenes. These methods have been tested under laboratory conditions and are specific for individual chemicals rather than for groups of chemicals. (JN)

  6. Modernization of laboratories of test of electric measurer

    International Nuclear Information System (INIS)

    Cuervo, Luis Felipe

    1999-01-01

    The paper presents to the companies that possess test laboratories and calibration of electric measurer, an economic alternative for their modernization, using the repontentiation like an economic solution that it liberates resources to be used in other areas that they want it

  7. Avoidance test with Eisenia fetida as indicator for the habitat function of soils. Results of a laboratory comparison test

    Energy Technology Data Exchange (ETDEWEB)

    Hund-Rinke, K. [Fraunhofer Inst. for Molecular Biology and Applied Ecology, Schmallenberg (Germany); Achazi, R.; Warnecke, D. [Free Univ. of Berlin, Inst. for Biology, Berlin (Germany); Roembke, J. [ECT Oekotoxikologie GmbH, Floersheim (Germany)

    2003-07-01

    Intention, Goal, Scope, Background. The habitat function of soils is often assessed using the reproduction test with Eisenia fetida. As this test is rather labour-intensive, an alternative is needed which is less cost-intensive in terms of duration and workload, but gives reasonable results. The avoidance test with E. fetida is a suitable screening test meeting these criteria. However, before a novel test system can be generally recommended it has to be ensured that comparable results are acquired from different laboratories on the basis of the respective test guideline. Objective. The avoidance test with E. fetida was performed as laboratory comparison test. The results were compared with those of the earthworm acute and reproduction tests carried out with the same soils. Methods. The three tests were performed by three laboratories using eight contaminated soils and three control soils. The contaminated soils were mixed with the control soils to obtain different concentrations of the contamination. (orig.)

  8. Effect of Popping Chocolate and Candy on Enamel Microhardness of Primary and Permanent Teeth.

    Science.gov (United States)

    Tabari, Mitra; Alaghemand, Homayoon; Qujeq, Durdi; Mohammadi, Elahe

    2017-01-01

    Dental erosion is a common disease in children. Food diets, due to high amounts of juice, soft drinks, chewing gum, and acidic chocolate, are one of the most important risk factors in erosive processes among children. The aim of this study was to evaluate the effect of candy and chocolate on the microhardness of tooth enamel. Two types of popping candy and one type of popping chocolate were used in this study. Thirty-three healthy permanent premolar teeth and 33 primary incisor teeth (A or B) were selected. Five grams of each popping chocolate or candy was dissolved with 2 ml of artificial saliva. Subsequently, their pH and titrable acidity (TA) as well as microhardness and surface roughness of enamel were examined in the laboratory. Data were analyzed and evaluated Released 2011. IBM SPSS Statistics for Windows, Version 20.0. Armonk, NY through independent t -test, paired t -test, Tukey test, and ANOVA. The results of this study showed that only the pH of the candies was below the critical pH of the enamel (5.5) and their TA was B = 0.20 and C = 0.21. The most significant effect on the enamel microhardness of the permanent and primary teeth was by the following types of candy: orange flavor (C), strawberry flavor (B), and chocolate (A), respectively. This difference was significant ( P < 0.001) and the surface roughness increased after exposure. This study showed that popping chocolate and candy reduces microhardness of enamel.

  9. [Improved design of permanent maglev impeller assist heart].

    Science.gov (United States)

    Qian, Kunxi; Zeng, Pei; Ru, Weimin; Yuan, Haiyu

    2002-12-01

    Magnetic bearing has no mechanical contact between the rotor and stator. And a rotary pump with magnetic bearing has therefore no mechanical wear and thrombosis due to bearing. The available magnetic bearings, however, are devised with electric magnets, need complicated control and remarkable energy consumption. Resultantly, it is difficult to apply an electric magnetic bearing to rotary pump without disturbing its simplicity, implantability and reliability. The authors have developed a levitated impeller pump merely with permanent magnets. The rotor is supported by permanent magnetic forces radially. On one side of the rotor, the impeller is fixed; and on the other side of the rotor, the driven magnets are mounted. Opposite to this driven magnets, a driving motor coil with iron corn magnets is fastened to the motor axis. Thereafter, the motor drives the rotor via a rotating magnetic field. By laboratory tests with saline, if the rotor stands still or rotates under 4,000 rpm, the rotor has one-point contact axially with the driving motor coil. The contacting point is located in the center of the rotor. As the rotating speed increases gradually to more than 4,000 rpm, the rotor will detache from the stator axially. Then the rotor will be fully levitated. Since the axial levitation is produced by hydraulic force and the driven magnets have a gyro-effect, the rotor rotates very steadly during levitation. As a left ventricular assist device, the pump works in a rotating speed range of 5,000-8,000 rpm, the levitation of the impeller hence is ensured by practical use of the pump.

  10. 42 CFR 493.1415 - Condition: Laboratories performing moderate complexity testing; clinical consultant.

    Science.gov (United States)

    2010-10-01

    ... § 493.1415 Condition: Laboratories performing moderate complexity testing; clinical consultant. The laboratory must have a clinical consultant who meets the qualification requirements of § 493.1417 of this... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Laboratories performing moderate...

  11. Laboratory Diagnosis and Susceptibility Testing for Mycobacterium tuberculosis.

    Science.gov (United States)

    Procop, Gary W

    2016-12-01

    The laboratory, which utilizes some of the most sophisticated and rapidly changing technologies, plays a critical role in the diagnosis of tuberculosis. Some of these tools are being employed in resource-challenged countries for the rapid detection and characterization of Mycobacterium tuberculosis. Foremost, the laboratory defines appropriate specimen criteria for optimal test performance. The direct detection of mycobacteria in the clinical specimen, predominantly done by acid-fast staining, may eventually be replaced by rapid-cycle PCR. The widespread use of the Xpert MTB/RIF (Cepheid) assay, which detects both M. tuberculosis and key genetic determinants of rifampin resistance, is important for the early detection of multidrug-resistant strains. Culture, using both broth and solid media, remains the standard for establishing the laboratory-based diagnosis of tuberculosis. Cultured isolates are identified far less commonly by traditional biochemical profiling and more commonly by molecular methods, such as DNA probes and broad-range PCR with DNA sequencing. Non-nucleic acid-based methods of identification, such as high-performance liquid chromatography and, more recently, matrix-assisted laser desorption/ionization-time of flight mass spectrometry, may also be used for identification. Cultured isolates of M. tuberculosis should be submitted for susceptibility testing according to standard guidelines. The use of broth-based susceptibility testing is recommended to significantly decrease the time to result. Cultured isolates may also be submitted for strain typing for epidemiologic purposes. The use of massive parallel sequencing, also known as next-generation sequencing, promises to continue to this molecular revolution in mycobacteriology, as whole-genome sequencing provides identification, susceptibility, and typing information simultaneously.

  12. Utility of repeat testing of critical values: a Q-probes analysis of 86 clinical laboratories.

    Science.gov (United States)

    Lehman, Christopher M; Howanitz, Peter J; Souers, Rhona; Karcher, Donald S

    2014-06-01

    A common laboratory practice is to repeat critical values before reporting the test results to the clinical care provider. This may be an unnecessary step that delays the reporting of critical test results without adding value to the accuracy of the test result. To determine the proportions of repeated chemistry and hematology critical values that differ significantly from the original value as defined by the participating laboratory, to determine the threshold differences defined by the laboratory as clinically significant, and to determine the additional time required to analyze the repeat test. Participants prospectively reviewed critical test results for 4 laboratory tests: glucose, potassium, white blood cell count, and platelet count. Participants reported the following information: initial and repeated test result; time initial and repeat results were first known to laboratory staff; critical result notification time; if the repeat result was still a critical result; if the repeat result was significantly different from the initial result, as judged by the laboratory professional or policy; significant difference threshold, as defined by the laboratory; the make and model of the instrument used for primary and repeat testing. Routine, repeat analysis of critical values is a common practice. Most laboratories did not formally define a significant difference between repeat results. Repeated results were rarely considered significantly different. Median repeated times were at least 17 to 21 minutes for 10% of laboratories. Twenty percent of laboratories reported at least 1 incident in the last calendar year of delayed result reporting that clinicians indicated had adversely affected patient care. Routine repeat analysis of automated chemistry and hematology critical values is unlikely to be clinically useful and may adversely affect patient care.

  13. Qualification of testing laboratories of Comision Nacional de Energia Atomica - CNEA

    International Nuclear Information System (INIS)

    Casa, Adriana; Palacios, Tulio; Peretti, Matilde; Pucci, Gladys; Resnizki, Sara

    1996-01-01

    Testing and calibration laboratories of the Argentine Atomic Energy Commission which made services for the nuclear and conventional industries must prove the reliability of their results. It is achieved implanting at the laboratories, a management quality system, to proof the capacity and technical aptitude, with the establish minimal requirements. When the requirement are fulfilled, the laboratory would be in conditions for a national level accreditation within the National System of Standards, Quality and Certification, recently created for our national government. The Laboratories Calibration Board of CNEA had made some assessments of a group of laboratories in order to determine their quality level. (author)

  14. [Unnecessary routine laboratory tests in patients referred for surgical services].

    Science.gov (United States)

    Mata-Miranda, María del Pilar; Cano-Matus, Norberto; Rodriguez-Murrieta, Margarita; Guarneros-Zapata, Idalia; Ortiz, Mario

    2016-01-01

    To question the usefulness of the lab analysis considered routine testing for the identification of abnormalities in the surgical care. To determine the percentage of unnecessary laboratory tests in the preoperative assessment as well as to estimate the unnecessary expenses. A descriptive, cross-sectional study of patients referred for surgical evaluation between January 1st and March 31st 2013. The database of laboratory testing and electronic files were reviewed. Reference criteria from surgical services were compared with the tests requested by the family doctor. In 65% of the patients (n=175) unnecessary examinations were requested, 25% (n=68) were not requested the tests that they required, and only 10% of the patients were requested laboratory tests in accordance with the reference criteria (n=27). The estimated cost in unnecessary examinations was $1,129,552 in a year. The results were similar to others related to this theme, however, they had not been revised from the perspective of the first level of attention regarding the importance of adherence to the reference criteria which could prevent major expenditures. It is a priority for leaders and operational consultants in medical units to establish strategies and lines of action that ensure compliance with institutional policies so as to contain spending on comprehensive services, and which in turn can improve the medical care. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  15. The Livermore Free-Electron Laser Program Magnet Test Laboratory

    International Nuclear Information System (INIS)

    Burns, M.J.; Kulke, B.; Deis, G.A.; Frye, R.W.; Kallman, J.S.; Ollis, C.W.; Tyler, G.C.; Van Maren, R.D.; Weiss, W.C.

    1987-01-01

    The Lawrence Livermore National Laboratory (LLNL) Free-Electron Laser Program Magnet Test Laboratory supports the ongoing development of the Induction Linac Free Electron Laser (IFEL) and uses magnetic field measurement systems that are useful in the testing of long periodic magnetic structures, electron-beam transport magnets, and spectrometer magnets. The major systems described include two computer-controlled, three-axis Hall probe-and-search coil transports with computer-controlled data acquisition; a unique, automated-search coil system used to detect very small inaccuracies in wiggler fields; a nuclear magnetic resonance (NMR)-based Hall probe-calibration facility; and a high-current DC ion source using heavy ions of variable momentum to model the transport of high-energy electrons. Additionally, a high-precision electron-beam-position monitor for use within long wigglers that has a positional resolution of less than 100 μm is under development in the laboratory and will be discussed briefly. Data transfer to LLNL's central computing facility and on-line graphics enable us to analyze large data sets quickly. 3 refs

  16. Recent package testing successes at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Ludwig, S.B.; Singley, P.T.; Michelhaugh, R.D.; Hawk, M.B.; Shappert, L.B.

    2004-01-01

    Oak Ridge National Laboratory (ORNL)'s history of testing of radioactive material packages dates back to the early 1960s, and includes the testing of hundreds of different packages of all shapes and sizes. This paper provides an overview of ORNL's new Packaging Research Facility (PRF) at the National Transportation Research Center (NTRC), and describes recent package testing successes conducted at the NTRC from September 2002 to September 2003

  17. Laboratory testing of LITCO glasses

    International Nuclear Information System (INIS)

    Ellison, A.; Wolf, S.; Buck, E.; Luo, J.S.; Dietz, N.; Bates, J.K.; Ebert, W.L.

    1995-01-01

    The purpose of this program is to measure, the intermediate and long-term durability of glasses developed by Lockheed Idaho Technology Co. (LITCO) for the immobilization of calcined radioactive wastes. The objective is to use accelerated corrosion tests as an aid in developing durable waste form compositions. This is a report of tests performed on two LITCO glass compositions, Formula 127 and Formula 532. The main avenue for release of radionuclides into the environment in a geologic repository is the reaction of a waste glass with ground water, which alters the glass and releases its components into solution. These stages in glass corrosion are analyzed by using accelerated laboratory tests in which the ratio of sample surface area to solution volume, SA/V, is varied. At low SA/V, the solution concentrations of glass corrosion products remain low and the reaction approaches the forward rate. At higher SA/V the solution approaches saturation levels for glass corrosion products. At very high SA/V the solution is rapidly saturated in glass corrosion products and secondary crystalline phases precipitate. Tests at very high SA/V provide information about the composition of the solution at saturation or, when no solution is recovered, the identities and the order of appearance of secondary crystalline phases. Tests were applied to Formula 127 and Formula 532 glasses to provide information about the interim and long-term stages in glass corrosion

  18. [Contribution of HCV core antigen testing in HCV diagnosis by test from the company Abbott Laboratories].

    Science.gov (United States)

    Trbusek, J

    2009-11-01

    Detection of HCV core antigen as direct marker of hepatitis C infection clearly improves diagnosis of this disease (especially reduction of window period) and brings broad clinical utilization. The company Abbott Laboratories offers fully automated laboratory test for measurement of HCV core antigen on ARCHITECT analyzers.

  19. Standard test method for laboratory evaluation of magnesium sacrificial anode test specimens for underground applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers a laboratory procedure that measures the two fundamental performance properties of magnesium sacrificial anode test specimens operating in a saturated calcium sulfate, saturated magnesium hydroxide environment. The two fundamental properties are electrode (oxidation potential) and ampere hours (Ah) obtained per unit mass of specimen consumed. Magnesium anodes installed underground are usually surrounded by a backfill material that typically consists of 75 % gypsum (CaSO4·2H2O), 20 % bentonite clay, and 5 % sodium sulfate (Na2SO4). The calcium sulfate, magnesium hydroxide test electrolyte simulates the long term environment around an anode installed in the gypsum-bentonite-sodium sulfate backfill. 1.2 This test method is intended to be used for quality assurance by anode manufacturers or anode users. However, long term field performance properties may not be identical to property measurements obtained using this laboratory test. Note 1—Refer to Terminology G 15 for terms used ...

  20. Permanent magnet finger-size scanning electron microscope columns

    Energy Technology Data Exchange (ETDEWEB)

    Nelliyan, K., E-mail: elenk@nus.edu.sg [Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117576 (Singapore); Khursheed, A. [Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117576 (Singapore)

    2011-07-21

    This paper presents permanent magnet scanning electron microscope (SEM) designs for both tungsten and field emission guns. Each column makes use of permanent magnet technology and operates at a fixed primary beam voltage. A prototype column operating at a beam voltage of 15 kV was made and tested inside the specimen chamber of a conventional SEM. A small electrostatic stigmator unit and dedicated scanning coils were integrated into the column. The scan coils were wound directly around the objective lens iron core in order to reduce its size. Preliminary experimental images of a test grid specimen were obtained through the prototype finger-size column, demonstrating that it is in principle feasible.

  1. Permanent magnet finger-size scanning electron microscope columns

    International Nuclear Information System (INIS)

    Nelliyan, K.; Khursheed, A.

    2011-01-01

    This paper presents permanent magnet scanning electron microscope (SEM) designs for both tungsten and field emission guns. Each column makes use of permanent magnet technology and operates at a fixed primary beam voltage. A prototype column operating at a beam voltage of 15 kV was made and tested inside the specimen chamber of a conventional SEM. A small electrostatic stigmator unit and dedicated scanning coils were integrated into the column. The scan coils were wound directly around the objective lens iron core in order to reduce its size. Preliminary experimental images of a test grid specimen were obtained through the prototype finger-size column, demonstrating that it is in principle feasible.

  2. RESULTS OF THE FIRST MI-171A2 FLYING LABORATORY TEST PHASE

    OpenAIRE

    V. A. Ivchin; K. Y. Samsonov

    2014-01-01

    The present publication describes the results of the first stage of the flying laboratory (Mi-171 helicopter) flight tests performed at Mil Moscow Helicopter Plant, JSC facilities. Main rotor components with blades made of polymer composite materials and X-type tail rotor were tested on the Mi-171 № 14987, flying laboratory, under Mi-171A Helicopter Retrofit Program.

  3. 42 CFR 493.1467 - Condition: Laboratories performing high complexity testing; cytology general supervisor.

    Science.gov (United States)

    2010-10-01

    ... testing; cytology general supervisor. 493.1467 Section 493.1467 Public Health CENTERS FOR MEDICARE....1467 Condition: Laboratories performing high complexity testing; cytology general supervisor. For the subspecialty of cytology, the laboratory must have a general supervisor who meets the qualification...

  4. Laboratory and field tests for radionuclide migration and high flow paths in clay

    International Nuclear Information System (INIS)

    Bourke, P.J.; Jefferies, N.L.; Lineham, T.R.; Nesirky, P.

    1991-01-01

    Two investigations have been undertaken in this programme. The principal investigation was at Culham Laboratory, England, where water flow within the Kimmeridge clay was measured. A subsidiary investigation at SCK/CEN was undertaken at the Underground Research Laboratory SCK/CEN Mol, Belgium, where an in situ measurement of solute transport by diffusion was attempted. The in situ migration experiment at the Underground Research Laboratory at SCK/CEN Mol, Belgium, was unsuccessful, due to problems with the engineering installation. These difficulties caused significant disturbance to the Boom clay which was to be tested. Nevertheless the laboratory test proved the feasibility of the experiment. The field measurements at Culham Laboratory, Oxfordshire, were completed with the flow testing of a very silty clay horizon in the Kimmeridge clay. This layer was proved to be laterally continuous after drilling three exploratory boreholes. The hydraulic conductivity of the layer was ≥ 10 -8 ms -1 and comparative tests in the clay showed the conductivity of the clay to be at least 50 times less. 12 figs

  5. Expert Assessment of Conditions for Accredited Quality Management System Functioning in Testing Laboratories

    Science.gov (United States)

    Mytych, Joanna; Ligarski, Mariusz J.

    2018-03-01

    The quality management systems compliant with the ISO 9001:2009 have been thoroughly researched and described in detail in the world literature. The accredited management systems used in the testing laboratories and compliant with the ISO/IEC 17025:2005 have been mainly described in terms of the system design and implementation. They have also been investigated from the analytical point of view. Unfortunately, a low number of studies concerned the management system functioning in the accredited testing laboratories. The aim of following study was to assess the management system functioning in the accredited testing laboratories in Poland. On 8 October 2015, 1,213 accredited testing laboratories were present in Poland. They investigated various scientific areas and substances/objects. There are more and more such laboratories that have various problems and different long-term experience when it comes to the implementation, maintenance and improvement of the management systems. The article describes the results of the conducted expert assessment (survey) carried out to examine the conditions for the functioning of a management system in an accredited laboratory. It also focuses on the characteristics of the accredited research laboratories in Poland. The authors discuss the selection of the external and internal conditions that may affect the accredited management system. They show how the experts assessing the selected conditions were chosen. The survey results are also presented.

  6. Policies and practices in haemostasis testing among laboratories in Croatia: a survey on behalf of a Working Group for Laboratory Coagulation of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    Science.gov (United States)

    Bronić, Ana; Herak, Desiree Coen; Margetić, Sandra; Milić, Marija

    2017-02-15

    The objective of this survey was to assess current policies and practice in haemostasis testing among both hospital and outpatient laboratories in Republic of Croatia. A questionnaire with seventy questions divided into nine sections was created in May 2015. Participants were asked about their practice related to test request form, sample collection, prothrombin time (PT) and activated partial thromboplastin time assays, other individual haemostasis assays, point-of-care testing (POCT), reporting of coagulation tests results and quality assurance of procedures, the personnel and other laboratory resources, as well as on issues related to education and implementation of additional coagulation assays in their laboratory. The survey was administered and data were collected between June and September 2015. A total survey response rate was 104/170 (61.2%). Most respondents were faced with incomplete information on prescribed therapy and diagnosis on the test request or inappropriate samples withdrawn on distant locations, but also do not have protocols for handling samples with high haematocrit values. Reporting of PT-INR and D-dimer results was different between laboratories. Although almost all laboratories developed a critical value reporting system, reporting a value to general practitioners is still a problem. Result on coagulation POCT testing showed that not all devices were supervised by laboratories, which is not in compliance with Croatian Chamber of Medical Biochemistry acts. Obtained results highlighted areas that need improvement and different practice patterns in particular field of haemostasis testing among laboratories. A harmonization of the overall process of haemostasis testing at national level should be considered and undertaken.

  7. Research of influence of open-winding faults on properties of brushless permanent magnets motor

    Science.gov (United States)

    Bogusz, Piotr; Korkosz, Mariusz; Powrózek, Adam; Prokop, Jan; Wygonik, Piotr

    2017-12-01

    The paper presents an analysis of influence of selected fault states on properties of brushless DC motor with permanent magnets. The subject of study was a BLDC motor designed by the authors for unmanned aerial vehicle hybrid drive. Four parallel branches per each phase were provided in the discussed 3-phase motor. After open-winding fault in single or few parallel branches, a further operation of the motor can be continued. Waveforms of currents, voltages and electromagnetic torque were determined in discussed fault states based on the developed mathematical and simulation models. Laboratory test results concerning an influence of open-windings faults in parallel branches on properties of BLDC motor were presented.

  8. Research of influence of open-winding faults on properties of brushless permanent magnets motor

    Directory of Open Access Journals (Sweden)

    Bogusz Piotr

    2017-12-01

    Full Text Available The paper presents an analysis of influence of selected fault states on properties of brushless DC motor with permanent magnets. The subject of study was a BLDC motor designed by the authors for unmanned aerial vehicle hybrid drive. Four parallel branches per each phase were provided in the discussed 3-phase motor. After open-winding fault in single or few parallel branches, a further operation of the motor can be continued. Waveforms of currents, voltages and electromagnetic torque were determined in discussed fault states based on the developed mathematical and simulation models. Laboratory test results concerning an influence of open-windings faults in parallel branches on properties of BLDC motor were presented.

  9. Diagnostic and laboratory test ordering in Northern Portuguese Primary Health Care: a cross-sectional study

    Science.gov (United States)

    Sá, Luísa; Teixeira, Andreia Sofia Costa; Tavares, Fernando; Costa-Santos, Cristina; Couto, Luciana; Costa-Pereira, Altamiro; Hespanhol, Alberto Pinto; Santos, Paulo

    2017-01-01

    Objectives To characterise the test ordering pattern in Northern Portugal and to investigate the influence of context-related factors, analysing the test ordered at the level of geographical groups of family physicians and at the level of different healthcare organisations. Design Cross-sectional study. Setting Northern Primary Health Care, Portugal. Participants Records about diagnostic and laboratory tests ordered from 2035 family physicians working at the Northern Regional Health Administration, who served approximately 3.5 million Portuguese patients, in 2014. Outcomes To determine the 20 most ordered diagnostic and laboratory tests in the Northern Regional Health Administration; to identify the presence and extent of variations in the 20 most ordered diagnostic and laboratory tests between the Groups of Primary Care Centres and between health units; and to study factors that may explain these variations. Results The 20 most ordered diagnostic and laboratory tests almost entirely comprise laboratory tests and account for 70.9% of the total tests requested. We can trace a major pattern of test ordering for haemogram, glucose, lipid profile, creatinine and urinalysis. There was a significant difference (P<0.001) in test orders for all tests between Groups of Primary Care Centres and for all tests, except glycated haemoglobin (P=0.06), between health units. Generally, the Personalised Healthcare Units ordered more than Family Health Units. Conclusions The results from this study show that the most commonly ordered tests in Portugal are laboratory tests, that there is a tendency for overtesting and that there is a large variability in diagnostic and laboratory test ordering in different geographical and organisational Portuguese primary care practices, suggesting that there may be considerable potential for the rationalisation of test ordering. The existence of Family Health Units seems to be a strong determinant in decreasing test ordering by Portuguese family

  10. Permanences GAG-EPA

    CERN Document Server

    GAC-EPA

    2015-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 5 mai de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 2 juin, 1er septembre, 6 octobre, 3 novembre et 1er décembre 2015. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires.

  11. Real-time laboratory exercises to test contingency plans for classical swine fever: experiences from two national laboratories

    DEFF Research Database (Denmark)

    Koenen, K.; Uttenthal, Åse; Meindl-Böhmer, A.

    2007-01-01

    In order to adequately and efficiently handle outbreaks of contagious diseases such as classical swine fever (CSF), foot and mouth disease or highly pathogenic avian influenza, competent authorities and the laboratories involved have to be well prepared and must be in possession of functioning....... It is essential that these plans are established during ‘peace-time’ and are reviewed regularly. This paper provides suggestions on how to perform laboratory exercises to test preparedness and describes the experiences of two national reference laboratories for CSF. The major lesson learnt was the importance...

  12. Crush Testing at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Feldman, Matthew R.

    2011-01-01

    The dynamic crush test is required in the certification testing of some small Type B transportation packages. International Atomic Energy Agency regulations state that the test article must be 'subjected to a dynamic crush test by positioning the specimen on the target so as to suffer maximum damage.' Oak Ridge National Laboratory (ORNL) Transportation Technologies Group performs testing of Type B transportation packages, including the crush test, at the National Transportation Research Center in Knoxville, Tennessee (United States). This paper documents ORNL's experiences performing crush tests on several different Type B packages. ORNL has crush tested five different drum-type package designs, continuing its 60 year history of RAM package testing. A total of 26 crush tests have been performed in a wide variety of package orientations and crush plate CG alignments. In all cases, the deformation of the outer drum created by the crush test was significantly greater than the deformation damage caused by the 9 m drop test. The crush test is a highly effective means for testing structural soundness of smaller nondense Type B shipping package designs. Further regulatory guidance could alleviate the need to perform the crush test in a wide range of orientations and crush plate CG alignments.

  13. A test of the permanent income hypothesis on Czech voucher privatization

    Czech Academy of Sciences Publication Activity Database

    Hanousek, Jan; Tůma, Z.

    2002-01-01

    Roč. 10, č. 2 (2002), s. 235-254 ISSN 0967-0750 Institutional research plan: CEZ:AV0Z7085904 Keywords : Barro-Riccardian * equivalence * permanent income hypothesis Subject RIV: AH - Economics Impact factor: 0.897, year: 2002 http://search. ebscohost .com/login.aspx?direct=true&db=bth&AN=6844845&site=ehost-live

  14. MagLev Cobra: Test Facilities and Operational Experiments

    International Nuclear Information System (INIS)

    Sotelo, G G; Dias, D H J N; De Oliveira, R A H; Ferreira, A C; De Andrade, R Jr; Stephan, R M

    2014-01-01

    The superconducting MagLev technology for transportation systems is becoming mature due to the research and developing effort of recent years. The Brazilian project, named MagLev-Cobra, started in 1998. It has the goal of developing a superconducting levitation vehicle for urban areas. The adopted levitation technology is based on the diamagnetic and the flux pinning properties of YBa 2 Cu 3 O 7−δ (YBCO) bulk blocks in the interaction with Nd-Fe-B permanent magnets. A laboratory test facility with permanent magnet guideway, linear induction motor and one vehicle module is been built to investigate its operation. The MagLev-Cobra project state of the art is presented in the present paper, describing some construction details of the new test line with 200 m.

  15. RESULTS OF THE FIRST MI-171A2 FLYING LABORATORY TEST PHASE

    Directory of Open Access Journals (Sweden)

    V. A. Ivchin

    2014-01-01

    Full Text Available The present publication describes the results of the first stage of the flying laboratory (Mi-171 helicopter flight tests performed at Mil Moscow Helicopter Plant, JSC facilities. Main rotor components with blades made of polymer composite materials and X-type tail rotor were tested on the Mi-171 № 14987, flying laboratory, under Mi-171A Helicopter Retrofit Program.

  16. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Science.gov (United States)

    2010-10-01

    ... Procedural Terminology published by the American Medical Association. (3) Levels of supervision. Except where... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...

  17. Feasibility of using overburden clays for sealing purposes and laboratory testing of the clays

    Energy Technology Data Exchange (ETDEWEB)

    Mann, J. (Vyzkumny Ustav pro Hnede Uhli, Most (Czechoslovakia))

    1992-03-01

    Studies properties of overburden clay from North Bohemian surface coal mines for use as sealants of industrial and household waste that will be dumped at Czechoslovak surface mine sites. Basic requirements of sealing layers are optimum compressibility and impermeability by suitable compacting. Laboratory soil mechanical tests of different clay samples were carried out using the Proctor standard tests (PCS) and the Norwegian Geonor A/S - m 45 instrument. Laboratory tests were used to select the best available clay types with optimum density and moisture content. Experimental results of laboratory tests are provided.

  18. A laboratory dispersant effectiveness test which reflects dispersant efficiency in the field

    International Nuclear Information System (INIS)

    Lunel, T.; Wood, P.

    1996-01-01

    Oil dispersion efficiencies of surfactants, from laboratory dispersion tests and field data were compared and calibrated. Data from an oil spill, where dispersants were used as a major part of the response, was analysed. The data was accumulated through the monitoring of the dispersant operation of the Sea Empress spill incident, in which Forties Blend oil was spilled at sea. This detailed data set was used to calibrate existing laboratory dispersant tests, and to devise a new International Dispersant Effectiveness Test. The objective was to create a comprehensive guide to decision making on whether and when to start a dispersant spraying operation. The dispersion efficiencies obtained from the laboratory dispersant tests were compared with field data. Flume tests produced the highest percentage of dispersed oil for all the dispersal tests. However, it was emphasised that the total percentage of oil dispersed should not be the only measure of dispersant effectiveness, since it does not distinguish between the contribution of natural and chemically enhanced dispersion. 9 refs., 1 tab., 9 figs

  19. Efficacy comparative of different laboratory test reagents for hepatitis C virus antibody

    Directory of Open Access Journals (Sweden)

    GUO Feibo

    2016-09-01

    Full Text Available Objective To investigate the effects of different laboratory test reagents for hepatitis C virus (HCV antibody through a comparative analysis. Methods A total of 207 samples which tested positive by four anti-HCV screening reagents commonly used in the laboratories in China (Kehua, Xinchuang, Wantai, and Abbott were included. HCV RNA nucleic acid amplification (NAT was performed, and if NAT results were negative, recombinant immunoblot assay (RIBA was performed for further confirmation. The test results of these four screening reagents were compared, and their S/CO values and true positive rates were analyzed. Results Of all the 205 samples testing positive by any one reagent, 191 (93.2% tested positive by the four reagents, and 14 (6.8% were tested inconsistently by the four reagents. The positive predictive values of Xinchuang, Kehua, Wantai, and Abbott reagents were 88.2% (180/204, 93.8% (180/192, 91.4% (180/197, and 90.0% (180/200, respectively. The S/CO thresholds with a positive predictive value of ≥95% for Xinchuang, Kehua, Wantai, and Abbott reagents were 9.0, 4.0, 5.0, and 7.0, respectively. Conclusion Xinchuang, Kehua, Wantai, and Abbott reagents have significantly different S/CO thresholds with a positive predictive value of ≥95%, which are significantly different from those in other domestic laboratories. Each laboratory should establish an applicable S/CO threshold with a positive predictive value of ≥95%, in order to reduce the sample size for confirmatory test.

  20. Economic viability, applications and limits of efficient permanent magnet motors - Summary and update; Wirtschaftlichkeit, Anwendungen und Grenzen von effizienten Permanent-Magnet-Motoren - Zusammenfassung und Update - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Lindegger, M. [Circle Motor AG, Guemligen (Switzerland); Biner, H.-P.; Evequoz, B. [Hochschule Westschweiz, Delemont (Switzerland); Salathe, D. [Hochschule Luzern Technik und Architektur, Horw (Switzerland)

    2009-06-15

    This final report for the Swiss Federal Office of Energy (SFOE), takes a look at the economic viability, applications and limits of efficient permanent magnet motors. Permanent magnet motors are compared with standard IEC asynchronous motors. In a theoretical part of the report, it is discussed how the increasing size of the motor influences efficiency, weight, volume and power. The results of practical tests carried out on six motors are presented. Three standard motors with varying efficiency were compared with three permanent-magnet motors for the power range around 3 kW. Market-oriented considerations concerning permanent-magnet motors are discussed. Operational criteria for the choice of the type of motor to be used are also examined.

  1. Effects of earthquake induced rock shear on containment system integrity. Laboratory testing plan development

    International Nuclear Information System (INIS)

    Read, Rodney S.

    2011-07-01

    This report describes a laboratory-scale testing program plan to address the issue of earthquake induced rock shear effects on containment system integrity. The document contains a review of relevant literature from SKB covering laboratory testing of bentonite clay buffer material, scaled analogue tests, and the development of related material models to simulate rock shear effects. The proposed testing program includes standard single component tests, new two-component constant volume tests, and new scaled analogue tests. Conceptual drawings of equipment required to undertake these tests are presented along with a schedule of tests. The information in this document is considered sufficient to engage qualified testing facilities, and to guide implementation of laboratory testing of rock shear effects. This document was completed as part of a collaborative agreement between SKB and Nuclear Waste Management Organization (NWMO) in Canada

  2. Effects of earthquake induced rock shear on containment system integrity. Laboratory testing plan development

    Energy Technology Data Exchange (ETDEWEB)

    Read, Rodney S. (RSRead Consulting Inc. (Canada))

    2011-07-15

    This report describes a laboratory-scale testing program plan to address the issue of earthquake induced rock shear effects on containment system integrity. The document contains a review of relevant literature from SKB covering laboratory testing of bentonite clay buffer material, scaled analogue tests, and the development of related material models to simulate rock shear effects. The proposed testing program includes standard single component tests, new two-component constant volume tests, and new scaled analogue tests. Conceptual drawings of equipment required to undertake these tests are presented along with a schedule of tests. The information in this document is considered sufficient to engage qualified testing facilities, and to guide implementation of laboratory testing of rock shear effects. This document was completed as part of a collaborative agreement between SKB and Nuclear Waste Management Organization (NWMO) in Canada

  3. Summary report - development of laboratory tests and the stress- strain behaviour of Olkiluoto mica gneiss

    International Nuclear Information System (INIS)

    Hakala, M.; Heikkilae, E.

    1997-05-01

    This work summarizes the project aimed at developing and qualifying a suitable combination of laboratory tests to establish a statistically reliable stress-strain behaviour of the main rock types at Posiva Oy's detailed investigation sites for disposal of spent nuclear fuel. The work includes literature study of stress-strain behaviour of brittle rock, development and qualification of laboratory tests, suggested test procedures and interpretation methods and finally testing of Olkiluoto mica gneiss. The Olkiluoto study includes over 130 loading tests. Besides the commonly used laboratory tests, direct tensile tests, damage controlled tests and acoustic emission measurements were also carried out. (orig.) (54 refs.)

  4. Laboratory testing of gneissic rocks in Olkiluoto borehole OL-KR24

    International Nuclear Information System (INIS)

    Eloranta, P.

    2006-10-01

    The stress-strain behaviour of anisotropic gneissic rocks from Olkiluoto, Finland, was studied for a total of 25 rock mechanics tests. Samples were selected from borehole OLKR24 at a depth level of 417-442 m. Tests included 15 uniaxial compression tests, 10 indirect tensile strength tests and 6 triaxial compression tests. Strain gauges were installed in five samples to evaluate the anisotropic properties, and acoustic emission sensors were installed in ten samples to estimate the stress damage levels. The specimen preparation and tests were carried out at the Laboratory of Rock Engineering, Helsinki University of Technology, Finland. Specimens were tested under laboratory-air-dry conditions and were photographed before and after the tests. The values obtained for the uniaxial compressive strength were in the range 56.5 - 165.9 MPa and for the indirect tensile strength 7.7 - 12.1 MPa. The anisotropic ratio of Young's modulus, E/E', was of the order of 1.1. (orig.)

  5. Valid methods: the quality assurance of test method development, validation, approval, and transfer for veterinary testing laboratories.

    Science.gov (United States)

    Wiegers, Ann L

    2003-07-01

    Third-party accreditation is a valuable tool to demonstrate a laboratory's competence to conduct testing. Accreditation, internationally and in the United States, has been discussed previously. However, accreditation is only I part of establishing data credibility. A validated test method is the first component of a valid measurement system. Validation is defined as confirmation by examination and the provision of objective evidence that the particular requirements for a specific intended use are fulfilled. The international and national standard ISO/IEC 17025 recognizes the importance of validated methods and requires that laboratory-developed methods or methods adopted by the laboratory be appropriate for the intended use. Validated methods are therefore required and their use agreed to by the client (i.e., end users of the test results such as veterinarians, animal health programs, and owners). ISO/IEC 17025 also requires that the introduction of methods developed by the laboratory for its own use be a planned activity conducted by qualified personnel with adequate resources. This article discusses considerations and recommendations for the conduct of veterinary diagnostic test method development, validation, evaluation, approval, and transfer to the user laboratory in the ISO/IEC 17025 environment. These recommendations are based on those of nationally and internationally accepted standards and guidelines, as well as those of reputable and experienced technical bodies. They are also based on the author's experience in the evaluation of method development and transfer projects, validation data, and the implementation of quality management systems in the area of method development.

  6. Can MOND type hypotheses be tested in a free fall laboratory environment?

    Science.gov (United States)

    Das, Saurya; Patitsas, S. N.

    2013-05-01

    The extremely small accelerations of objects required for the onset of modified Newtonian dynamics, or modified Newtonian dynamics (MOND), makes testing the hypothesis in conventional terrestrial laboratories virtually impossible. This is due to the large background acceleration of Earth, which is transmitted to the acceleration of test objects within an apparatus. We show, however, that it may be possible to test MOND-type hypotheses with experiments using a conventional apparatus capable of tracking very small accelerations of its components but performed in locally inertial frames such as artificial satellites and other freely falling laboratories. For example, experiments involving an optical interferometer or a torsion balance in these laboratories would show nonlinear dynamics and displacement amplitudes larger than expected. These experiments may also be able to test potential violations of the strong equivalence principle by MOND and to distinguish between its two possible interpretations (modified inertia and modified gravity).

  7. Characterizing permanent magnet blocks with Helmholtz coils

    Science.gov (United States)

    Carnegie, D. W.; Timpf, J.

    1992-08-01

    Most of the insertion devices to be installed at the Advanced Photon Source will utilize permanent magnets in their magnetic structures. The quality of the spectral output is sensitive to the errors in the field of the device which are related to variations in the magnetic properties of the individual blocks. The Advanced Photon Source will have a measurement facility to map the field in the completed insertion devices and equipment to test and modify the magnetic strength of the individual magnet blocks. One component of the facility, the Helmholtz coil permanent magnet block measurement system, has been assembled and tested. This system measures the total magnetic moment vector of a block with a precision better than 0.01% and a directional resolution of about 0.05°. The design and performance of the system will be presented.

  8. The changing face of hemostasis testing in modern laboratories: consolidation, automation, and beyond.

    Science.gov (United States)

    Lippi, Giuseppe; Plebani, Mario; Favaloro, Emmanuel J

    2015-04-01

    The reality of laboratory diagnostics as a whole, and hemostasis testing in particular, is evolving under new paradigms of efficiency. The driving forces of health care and laboratory diagnostics in the third millennium are mainly represented by macro- and microeconomics. In a world with limited resources, shattered by an unprecedented economic crisis, laboratory diagnostics is undergoing a substantial reorganization, with emergence of new models under the imperative of terms, such as bedside testing, consolidation, and networking. The paradigms under which these changes are being developed include a variety of environment, preanalytical, technological, professional, and health-care aspects. The maintenance of continued quality is indeed the major challenge to be faced in the foreseeable future. In fact, some challenges prepotently emerge during a consolidation process, which basically involve delayed testing, centrifugation, transportation, and stability of the specimens, as well as the potential mismatch of sample matrix. This article is aimed to provide an overview of the current economic scenario of laboratory diagnostics and discuss the changing face of hemostasis testing in modern laboratories, providing a synthetic overview about potential drawbacks of actualized solutions. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  9. [Object permanence in children with neurological and psychomotor disorders].

    Science.gov (United States)

    Pisaturo, C; Frassoni, S; Borreani, A; Battaglia, F; Meruzzi, B

    1995-06-01

    The aim of this research was to investigate whether the development of object permanence is an available sign of the cognitive development in infants with psychomotor handicaps. Subjects consisted of 5 males, ranging in age from 12 to 33 months, with handicaps as a result of perinatal brain injury. Four were preterm infants. All of the children received psychomotor treatment. Their stage of object permanence was assessed using traditional (B-L) and non traditional test (U-H). (The children's performances on the U-H scales have an "Intrinsic validity"). Four children achieved the first stages of the development of object permanence. The acquisition of object permanence was delayed in comparison with the age-appropriated time, but it may be considered adequate in comparison with the "developmental age" (B-L). One children with severe mental and motor disorders solved no task, the findings suggest that the children with psychomotor handicaps may gain the concept of object permanence and that psychomotor treatment may assist them in the development of the concept. This performance is not age-dependent. So the acquisition of the concept of object permanence may be considered an accurate and sensitive tool for the follow-up of the sensorimotor development in the handicapped children.

  10. Testing various modes of installation for permanent broadband stations in open field environment

    Science.gov (United States)

    Vergne, Jérôme; Charade, Olivier; Arnold, Benoît; Louis-Xavier, Thierry

    2014-05-01

    In the framework of the RESIF (Réseau Sismologique et géodésique Français) project, we plan to install more than one hundred new permanent broadband stations in metropolitan France within the next 6 years. Whenever possible, the sensors will be installed in natural or artificial underground cavities that provide a stable thermal environment. However such places do not exist everywhere and we expect that about half the future stations will have to be set up in open fields. For such sites, we are thus looking for a standard model of hosting infrastructure for the sensors that would be easily replicated and would provide good noise level performances at long periods. Since early 2013, we have been operating a prototype station at Clévilliers, a small location in the sedimentary Beauce plain, where we test three kinds of buried seismic vaults and a down-hole installation. The cylindrical seismic vaults are 3m deep and 1m wide and only differ by the type of coupling between the casing and the concrete slab where we installed insulated Trillium T120PA seismometers. The down-hole installation consists in a 3m deep well hosting a Trillium Posthole seismometer. For reference, another sensor has been installed in a ~50cm deep hole, similarly to the way we test every new potential site. Here we compare the noise level in each infrastructure at different frequencies. We observe quite similar performances for the vertical component recorded in the different wells. Conversely, the noise levels on the horizontal components at periods greater than 10s vary by more than 20dB depending on the installation condition. The best results are obtained in the completely decoupled vault and for the down-hole setting, both showing performances comparable to some of our permanent stations installed in tunnels. The amplitude of the horizontal noise also appears to be highly correlated to wind speed recorded on site, even at long periods. The variable response of each vault to such

  11. Radioelement gauges. Appliances intended for permanent installation

    International Nuclear Information System (INIS)

    1975-08-01

    The present norm defines for radioelement gauges intended for permanent installation: a classification of instruments and beam shutter devices; recommended construction techniques which satisfy health physics requirements; monitoring and test methods; information which must appear on the instruments [fr

  12. Use of Proficiency Testing as a Tool to Improve Quality in Microbiology Laboratories.

    Science.gov (United States)

    Stang, Heather L; Anderson, Nancy L

    2013-09-15

    Proficiency testing (PT) is a valuable tool for assessing laboratory performance and verifying the accuracy and reliability of test results. Participation is required by the Clinical Laboratory Improvement Amendments (CLIA) of 1988 for each of the microbiology subspecialties (bacteriology, mycobacteriology, mycology, parasitology, and virology), and the regulations include specific PT requirements for each subspecialty. To determine the use and perceived value of PT beyond meeting CLIA requirements, the Centers for Disease Control and Prevention funded a cooperative agreement with the Association of Public Health Laboratories to convene a series of focus groups to query laboratory professionals responsible for PT. The seven focus groups were comprised of 60 laboratory professionals representing large and small clinical laboratories, microbiology subspecialties, and public health. While participants acknowledged the need to perform PT to meet regulatory requirements, many also cited benefits and challenges beyond regulatory compliance.

  13. DTU PMU Laboratory Development - Testing and Validation

    DEFF Research Database (Denmark)

    Garcia-Valle, Rodrigo; Yang, Guang-Ya; Martin, Kenneth E.

    2010-01-01

    This is a report of the results of phasor measurement unit (PMU) laboratory development and testing done at the Centre for Electric Technology (CET), Technical University of Denmark (DTU). Analysis of the PMU performance first required the development of tools to convert the DTU PMU data into IEEE...... standard, and the validation is done for the DTU-PMU via a validated commercial PMU. The commercial PMU has been tested from the authors' previous efforts, where the response can be expected to follow known patterns and provide confirmation about the test system to confirm the design and settings....... In a nutshell, having 2 PMUs that observe same signals provides validation of the operation and flags questionable results with more certainty. Moreover, the performance and accuracy of the DTU-PMU is tested acquiring good and precise results, when compared with a commercial phasor measurement device, PMU-1....

  14. Reproducibility of pop-ins in laboratory testing of welded joints

    Directory of Open Access Journals (Sweden)

    Berejnoi C.

    2000-01-01

    Full Text Available The pop-in phenomenon, quite common in fracture mechanics tests of welded joints, corresponds to a brittle crack initiation grown from a local brittle zone (LBZ that is arrested in reaching the higher toughness material that surrounds this LBZ. A methodology to obtain a high percentage of pop-in occurrence in laboratory testing is necessary to study the pop-in significance. Such a method is introduced in this work and includes the consumable combination and welding procedures for the SMAW welding process to generate artificial LBZ. In order to find out the influence of the loading state upon the pop-in phenomenon, laboratory CTOD tests were performed using two specimen configurations: some single edge-notched specimens were loaded on a three-point bending (SE(B fixture while others were tested in tensile load (SE(T. A higher frequency of pop-in occurrence was observed in the SE(B geometry.

  15. Object permanence development in infants with motor handicaps.

    Science.gov (United States)

    Fetters, L

    1981-03-01

    This study was an investigation of the effects of a motor handicap on the development of object permanence in the young child. Motor abilities were evaluated for 12 infants aged 13 to 29 months. Based on this evaluation, the children were described as manipulators or nonmanipulators in reference to their upper extremity skills. Their stage of object permanence was assessed using traditional and nontraditional assessments. Heart rate and visual tracking were recorded during the nontraditional assessment. Heart rate did not significantly relate to visual fixation or search response. There was, however, a significant difference (p less than .02) between stage achievement with traditional testing and age-appropriate levels. There was no significant difference between the nontraditional assessment and the age-appropriate levels. In addition, there was no significant difference in the development of object permanence between infants described as manipulators and those described as nonmanipulators. The last two findings suggest that infants with motor handicaps may develop object permanence at the expected ages, according to a nontraditional assessment.

  16. Field and laboratory tests on acute toxicity of cadmium to freshwater crayfish

    Energy Technology Data Exchange (ETDEWEB)

    1986-09-01

    Environmental regulatory standards for cadmium (EPA 1980), like those for most pollutants, are based on acute, laboratory toxicity tests of single species. Such tests can be conducted rapidly and inexpensively in comparison to acute or chronic field studies, but their validity has often been questioned. Laboratory-based criteria are subject to two criticisms: (1) chemical and physical conditions differ greatly in degree and variability from laboratory to field, and (2) species are not isolated, but live in an ecosystem of interacting taxa and biofeedback. To investigate the validity of basing field toxicity standards on laboratory data, the authors subjected the freshwater crayfish Orconectes immunis for 96 h to various levels of cadmium in laboratory aquaria and experimental ponds. The study was designed to evaluate in part the first criticism of lab-based criteria. The studies were conducted concurrently with similar short-term experiments on the fathead minnow, Pimephales promelas, and coincided with studies of chronic cadmium stress on fathead minnows in experimental ponds.

  17. Summary report - development of laboratory tests and the stress- strain behaviour of Olkiluoto mica gneiss

    Energy Technology Data Exchange (ETDEWEB)

    Hakala, M.; Heikkilae, E. [Helsinki Univ. of Technology, Espoo (Finland). Lab. of Rock Engineering

    1997-05-01

    This work summarizes the project aimed at developing and qualifying a suitable combination of laboratory tests to establish a statistically reliable stress-strain behaviour of the main rock types at Posiva Oy`s detailed investigation sites for disposal of spent nuclear fuel. The work includes literature study of stress-strain behaviour of brittle rock, development and qualification of laboratory tests, suggested test procedures and interpretation methods and finally testing of Olkiluoto mica gneiss. The Olkiluoto study includes over 130 loading tests. Besides the commonly used laboratory tests, direct tensile tests, damage controlled tests and acoustic emission measurements were also carried out. (orig.) (54 refs.).

  18. [Approval of ISO/IEC 17025 and quality control of laboratory testing].

    Science.gov (United States)

    Yamamoto, Shigeki; Asakura, Hiroshi; Machii, Kenji; Igimi, Shizunobu

    2010-01-01

    First section of Division of Biomedical Food Research, National Institute of Health Sciences (NIHS) was approved by ISO/IEC 17025 as a laboratory having an appropriate laboratory testing technique. NIHS is the first national laboratory approved by ISO/IEC 17025. NIHS has also been accepted the appropriate technique and facility for the BSL3 level pathogens by ISO/IEC 17025. NIHS is necessary to take an external audit almost every year. This approval is renewed every 4 years.

  19. Technical performance of cementitious grouting materials for ONKALO. Laboratory tests 2006

    International Nuclear Information System (INIS)

    Raivio, P.; Hansen, J.

    2007-09-01

    During 2006 the development of high and low-pH cementitious grouts for fractures > 100 μm designed for the ONKALO rock was continued within the LPHTEK/IMAproject. The main focus in laboratory was to study high pH micro cement grouts. The low pH (≥ 11.0) of the cementitious grout material is required in deep repository as natural pH plume deriving from pure cement paste is very high and moves via ground water circulation in bedrock. This may be deleterious to the protective covers of nuclear waste. The objective to study high pH grouts in laboratory was to optimise their composition and to get preliminary test results. Low pH grouts based on Portland cement + micro silica were also studied further in laboratory to understand their behaviour more thoroughly in different conditions and due to quality changes in materials and to compare the laboratory results with the field results. Alternative fine-grained glass material was briefly studied to replace silica in low pH grout. Low and high pH rock bolt mortars were also developed and tested to get the preliminary test results. The results of the 2006 laboratory work are presented in this report. The high pH micro cement mix U1 with no silica, mix 5/5 with moderate silica and low pH mix P308B rich in silica show generally good properties at fresh and hardening stage at +12 deg C. Lower temperature gives weaker strength build-up with all the mixes and weakens especially the Marsh fluidity and penetration ability of the mixes 5/5 and P308B as bulk density rises a little at lower temperature. Cement quality variation and insufficient mixing may also weaken the properties of all mixes. Deformation of the hardened mixes was observed in laboratory tests. This may weaken their durability if cracks are formed in the grouts at later ages and need to be studied more thoroughly. (orig.)

  20. The Prevalence of Transient and Permanent Congenital Hypothyroidism in Infants of Kurdistan Province, Iran (2006-2014

    Directory of Open Access Journals (Sweden)

    Zaher khazaei

    2017-02-01

    Full Text Available Background: Congenital hypothyroidism (CH is the most common endocrine diseases and one of the major causes of preventable mental retardation. This study was conducted to investigate the prevalence of transient and permanent congenital hypothyroidism in Kurdistan province, Iran.Materials and Methods: In this cross-sectional study, all registered congenital hypothyroidism neonate of health centers of cities covered by Kurdistan University of Medical Sciences during 2006 to 2014 entered to study. Demographic and laboratory information of CH neonates was collected and entered into the Stata-12 and was analyzed using student t-test and Chi-square statistic and P- value less than 0.05 was considered.Results: Overall incidence rate during 2006 to 2014 for province was 1.8, 2.3, 3.2, 4.3, 3.3, 4.0, 3.6, 4.6 and 2.7, respectively per 1000 neonates in this period. The number of diagnosed patients was 855 cases including 519 (60.7% boys and 336 (39.3% girls who 516 (60.4% cases were from urban areas. Of the total patients, 202 (22.6% were permanent. There was no significant difference between gender, location, type of childbirth, and season of birth with transient and permanent types of disease (P˃0.05; while, there was a significant statistical relationship between consanguineous marriages and congenital hypothyroidism (P

  1. 3-D analysis of eddy current in permanent magnet of interior permanent magnet motors

    International Nuclear Information System (INIS)

    Kawase, Yoshihiro; Yamaguchi, Tadashi; Fukanaga, Hiromu; Ito, Shokichi

    2002-01-01

    Interior permanent magnet motors are widely used in various fields. However, in high-speed operations, it is important to decrease the eddy current loss in the permanent magnet. In order to decrease the eddy current loss, we propose to divide the permanent magnet. In this paper, we clarified the effect of division of permanent magnet on the eddy current loss using the 3-D finite element method. (Author)

  2. Point-Counterpoint: The FDA Has a Role in Regulation of Laboratory-Developed Tests.

    Science.gov (United States)

    Caliendo, Angela M; Hanson, Kimberly E

    2016-04-01

    Since the Food and Drug Administration (FDA) released its draft guidance on the regulation of laboratory-developed tests (LDTs) in October 2014, there has been a flurry of responses from commercial and hospital-based laboratory directors, clinicians, professional organizations, and diagnostic companies. The FDA defines an LDT as an "in vitrodiagnostic device that is intended for clinical use and is designed, manufactured, and used within a single laboratory." The draft guidance outlines a risk-based approach, with oversight of high-risk and moderate-risk tests being phased in over 9 years. High-risk tests would be regulated first and require premarket approval. Subsequently, moderate-risk tests would require a 510(k) premarket submission to the FDA and low-risk tests would need only to be registered. Oversight discretion would be exercised for LDTs focused on rare diseases (defined as fewer than 4,000 tests, not cases, per year nationally) and unmet clinical needs (defined as those tests for which there is no alternative FDA-cleared or -approved test). There was an open comment period followed by a public hearing in early January of 2015, and we are currently awaiting the final decision regarding the regulation of LDTs. Given that LDTs have been developed by many laboratories and are essential for the diagnosis and monitoring of an array of infectious diseases, changes in their regulation will have far-reaching implications for clinical microbiology laboratories. In this Point-Counterpoint, Angela Caliendo discusses the potential benefits of the FDA guidance for LDTs whereas Kim Hanson discusses the concerns associated with implementing the guidance and why these regulations may not improve clinical care. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  3. Development of laboratory acceleration test method for service life prediction of concrete structures

    International Nuclear Information System (INIS)

    Cho, M. S.; Song, Y. C.; Bang, K. S.; Lee, J. S.; Kim, D. K.

    1999-01-01

    Service life prediction of nuclear power plants depends on the application of history of structures, field inspection and test, the development of laboratory acceleration tests, their analysis method and predictive model. In this study, laboratory acceleration test method for service life prediction of concrete structures and application of experimental test results are introduced. This study is concerned with environmental condition of concrete structures and is to develop the acceleration test method for durability factors of concrete structures e.g. carbonation, sulfate attack, freeze-thaw cycles and shrinkage-expansion etc

  4. Comparison of torque capability of three-phase permanent magnet synchronous motors with different permanent magnet arrangement

    International Nuclear Information System (INIS)

    Stumberger, Bojan; Stumberger, Gorazd; Hadziselimovic, Miralem; Hamler, Anton; Gorican, Viktor; Jesenik, Marko; Trlep, Mladen

    2007-01-01

    The paper presents a comparison of torque capability of three-phase permanent magnet synchronous motors with different permanent magnet arrangement. Motors with the following permanent magnet topologies were accounted for in the comparison: the surface-mounted permanent magnet synchronous motor (SMPMSM), the interior permanent magnet synchronous motor (IPMSM), the permanent magnet-assisted synchronous reluctance motor (PMASRM) and the flux reversal permanent magnet motor (FRPMM). Finite element method analysis is employed to determine the performance of each motor. Calculated performance of four-pole IPMSM determined by finite element method calculation is confirmed with the measurements at nearly constant nominal output power in the range of speed 3000-10,000 rpm

  5. The Brookhaven National Laboratory Accelerator Test Facility

    International Nuclear Information System (INIS)

    Batchelor, K.

    1992-01-01

    The Brookhaven National Laboratory Accelerator Test Facility comprises a 50 MeV traveling wave electron linear accelerator utilizing a high gradient, photo-excited, raidofrequency electron gun as an injector and an experimental area for study of new acceleration methods or advanced radiation sources using free electron lasers. Early operation of the linear accelerator system including calculated and measured beam parameters are presented together with the experimental program for accelerator physics and free electron laser studies

  6. Impact of providing fee data on laboratory test ordering: a controlled clinical trial.

    Science.gov (United States)

    Feldman, Leonard S; Shihab, Hasan M; Thiemann, David; Yeh, Hsin-Chieh; Ardolino, Margaret; Mandell, Steven; Brotman, Daniel J

    2013-05-27

    Inpatient care providers often order laboratory tests without any appreciation for the costs of the tests. To determine whether we could decrease the number of laboratory tests ordered by presenting providers with test fees at the time of order entry in a tertiary care hospital, without adding extra steps to the ordering process. Controlled clinical trial. Tertiary care hospital. All providers, including physicians and nonphysicians, who ordered laboratory tests through the computerized provider order entry system at The Johns Hopkins Hospital. We randomly assigned 61 diagnostic laboratory tests to an "active" arm (fee displayed) or to a control arm (fee not displayed). During a 6-month baseline period (November 10, 2008, through May 9, 2009), we did not display any fee data. During a 6-month intervention period 1 year later (November 10, 2009, through May 9, 2010), we displayed fees, based on the Medicare allowable fee, for active tests only. We examined changes in the total number of orders placed, the frequency of ordered tests (per patient-day), and total charges associated with the orders according to the time period (baseline vs intervention period) and by study group (active test vs control). For the active arm tests, rates of test ordering were reduced from 3.72 tests per patient-day in the baseline period to 3.40 tests per patient-day in the intervention period (8.59% decrease; 95% CI, -8.99% to -8.19%). For control arm tests, ordering increased from 1.15 to 1.22 tests per patient-day from the baseline period to the intervention period (5.64% increase; 95% CI, 4.90% to 6.39%) (P fee data to providers at the time of order entry resulted in a modest decrease in test ordering. Adoption of this intervention may reduce the number of inappropriately ordered diagnostic tests.

  7. The development of Metacognition test in genetics laboratory for undergraduate students

    Science.gov (United States)

    A-nongwech, Nattapong; Pruekpramool, Chaninan

    2018-01-01

    The purpose of this research was to develop a Metacognition test in a Genetics Laboratory for undergraduate students. The participants were 30 undergraduate students of a Rajabhat university in Rattanakosin group in the second semester of the 2016 academic year using purposive sampling. The research instrument consisted of 1) Metacognition test and 2) a Metacognition test evaluation form for experts focused on three main points which were an accurate evaluation form of content, a consistency between Metacognition experiences and questions and the appropriateness of the test. The quality of the test was analyzed by using the Index of Consistency (IOC), discrimination and reliability. The results of developing Metacognition test were summarized as 1) The result of developing Metacognition test in a Genetics Laboratory for undergraduate students found that the Metacognition test contained 56 items of open - ended questions. The test composed of 1) four scientific situations, 2) fourteen items of open - ended questions in each scientific situation for evaluating components of Metacognition. The components of Metacognition consisted of Metacognitive knowledge, which were divided into person knowledge, task knowledge and strategy knowledge and Metacognitive experience, which were divided into planning, monitoring and evaluating, and 3) fourteen items of scoring criteria divided into four scales. 2) The results of the item analysis of Metacognition in Genetics Laboratory for undergraduate students found that Index of Consistency between Metacognitive experiences and questions were in the range between 0.75 - 1.00. An accuracy of content equaled 1.00. The appropriateness of the test equaled 1.00 in all situations and items. The discrimination of the test was in the range between 0.00 - 0.73. Furthermore, the reliability of the test equaled 0.97.

  8. Laboratory shake flask batch tests can predict field biodegradation of aniline in the Rhine

    DEFF Research Database (Denmark)

    Toräng, Lars; Reuschenbach, P.; Müller, B.

    2001-01-01

    .7 degreesC, respectively. This field rate estimate was compared with results from 38 laboratory shake flask batch tests with Rhine water which averaged 1.5 day(-1) at 15 degreesC and 2.0 day(-1) at 20 degreesC. These results indicate that laboratory shake flask batch tests with low concentrations of test...

  9. Single and Combined Diagnostic Value of Clinical Features and Laboratory Tests in Acute Appendicitis

    NARCIS (Netherlands)

    Laméris, Wytze; van Randen, Adrienne; Go, Peter M. N. Y. H.; Bouma, Wim H.; Donkervoort, Sandra C.; Bossuyt, Patrick M. M.; Stoker, Jaap; Boermeester, Marja A.

    2009-01-01

    Objectives: The objective was to evaluate the diagnostic accuracy of clinical features and laboratory test results in detecting acute appendicitis. Methods: Clinical features and laboratory test results were prospectively recorded in a consecutive series of 1,101 patients presenting with abdominal

  10. Laboratory testing in management of patients with suspected Ebolavirus disease: infection control and safety.

    Science.gov (United States)

    Gilbert, G L

    2015-08-01

    If routine laboratory safety precautions are followed, the risk of laboratory-acquired infection from handling specimens from patients with Ebolavirus disease (EVD) is very low, especially in the early 'dry' stage of disease. In Australia, border screening to identify travellers returning from EVD-affected west African countries during the 2014-2015 outbreak has made it unlikely that specimens from patients with unrecognised EVD would be sent to a routine diagnostic laboratory. Australian public health and diagnostic laboratories associated with hospitals designated for the care of patients with EVD have developed stringent safety precautions for EVD diagnostic and other tests likely to be required for supportive care of the sickest (and most infectious) patients with EVD, including as wide a range of point-of-care tests as possible. However, it is important that the stringent requirements for packaging, transport and testing of specimens that might contain Ebolavirus--which is a tier 1 security sensitive biology agent--do not delay the diagnosis and appropriate management of other potentially serious but treatable infectious diseases, which are far more likely causes of a febrile illness in people returning from west Africa. If necessary, urgent haematology, biochemistry and microbiological tests can be performed safely, whilst awaiting the results of EVD tests, in a PC-2 laboratory with appropriate precautions including: use of recommended personal protective equipment (PPE) for laboratory staff; handling any unsealed specimens in a class 1 or II biosafety cabinet; using only centrifuges with sealed rotors; and safe disposal or decontamination of all used equipment and laboratory waste.

  11. A possible laboratory test for the axions

    International Nuclear Information System (INIS)

    Ramachandran, G.; Vinay Deepak, H.S.; Thomas, Sujith; Raghunath, C.; Cowsik, R.

    2011-01-01

    The axion is a hypothetical light boson with spin zero which was introduced theoretically more than 3 decades ago, following the Peccei-Quinn solution to the strong CP problem. The axion is one amongst the candidates for dark matter along with neutrinos, WIMPS, SIMPS, CHAMPS and Super heavy particles which could possibly be detected by neutrino facilities like IceCube. The purpose of the present contribution is to suggest a laboratory test for the existence of axions

  12. Canadian Public Health Laboratory Network Laboratory Guidelines for the Use of Direct Tests to Detect Syphilis in Canada

    Directory of Open Access Journals (Sweden)

    Raymond SW Tsang

    2015-01-01

    Full Text Available Treponema pallidum subsp. pallidum and/or its nucleic acid can be detected by various methods such as microscopy, rabbit infectivity test or polymerase chain reaction (PCR tests. The rabbit infectivity test for T. pallidum, although very sensitive, has been discontinued from most laboratories due to ethical issues related to the need for animal inoculation with live T. pallidum, the technically demanding procedure and long turnaround time for results, thus making it impractical for routine diagnostic use. Dark-field and phase-contrast microscopy are still useful at clinic- or hospital-based laboratories for near-bedside detection of T. pallidum in genital, skin or mucous lesions although their availability is decreasing. The lack of reliable and specific anti-T. pallidum antibodies and its inferior sensitivity to PCR may explain why the direct fluorescent antibody test for T. pallidum is not widely available for clinical use. Immunohistochemical staining for T. pallidum also depends on the availability of specific antibodies, and the method is only applicable for histopathological examination of biopsy and autopsy specimens necessitating an invasive specimen collection approach. With recent advances in molecular diagnostics, PCR is considered to be the most reliable, versatile and practical for laboratories to implement. In addition to being an objective and sensitive test for direct detection of Treponema pallidum subsp. pallidum DNA in skin and mucous membrane lesions, the resulting PCR amplicons from selected gene targets can be further characterized for antimicrobial (macrolide susceptibility testing, strain typing and identification of T. pallidum subspecies.

  13. 9 CFR 54.11 - Approval of laboratories to run official scrapie tests and official genotype tests.

    Science.gov (United States)

    2010-01-01

    ... request approval to conduct one or more types of scrapie test or genotype test on one or more types of... type of test and for each type of tissue for which they request approval. (c) The Administrator may... the laboratory and shall give the director an opportunity to respond. If there are conflicts as to any...

  14. 9 CFR 55.8 - Official CWD tests and approval of laboratories to conduct official CWD tests.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Official CWD tests and approval of laboratories to conduct official CWD tests. 55.8 Section 55.8 Animals and Animal Products ANIMAL AND PLANT... on live or dead animals, and will base the approval or disapproval of a test on the evaluation by...

  15. Continuous Analytical Performances Monitoring at the On-Site Laboratory through Proficiency, Inter-Laboratory Testing and Inter-Comparison Analytical Methods

    International Nuclear Information System (INIS)

    Duhamel, G.; Decaillon, J.-G.; Dashdondog, S.; Kim, C.-K.; Toervenyi, A.; Hara, S.; Kato, S.; Kawaguchi, T.; Matsuzawa, K.

    2015-01-01

    Since 2008, as one measure to strengthen its quality management system, the On-Site Laboratory for nuclear safeguards at the Rokkasho Reprocessing Plant, has increased its participation in domestic and international proficiency and inter-laboratory testing for the purpose of determining analytical method accuracy, precision and robustness but also to support method development and improvement. This paper provides a description of the testing and its scheduling. It presents the way the testing was optimized to cover most of the analytical methods at the OSL. The paper presents the methodology used for the evaluation of the obtained results based on Analysis of variance (ANOVA). Results are discussed with respect to random, systematic and long term systematic error. (author)

  16. Laboratory test result interpretation for primary care doctors in South Africa

    Directory of Open Access Journals (Sweden)

    Naadira Vanker

    2017-03-01

    Full Text Available Background: Challenges and uncertainties with test result interpretation can lead to diagnostic errors. Primary care doctors are at a higher risk than specialists of making these errors, due to the range in complexity and severity of conditions that they encounter. Objectives: This study aimed to investigate the challenges that primary care doctors face with test result interpretation, and to identify potential countermeasures to address these. Methods: A survey was sent out to 7800 primary care doctors in South Africa. Questionnaire themes included doctors’ uncertainty with interpreting test results, mechanisms used to overcome this uncertainty, challenges with appropriate result interpretation, and perceived solutions for interpreting results. Results: Of the 552 responses received, the prevalence of challenges with result interpretation was estimated in an average of 17% of diagnostic encounters. The most commonly-reported challenges were not receiving test results in a timely manner (51% of respondents and previous results not being easily available (37%. When faced with diagnostic uncertainty, 84% of respondents would either follow-up and reassess the patient or discuss the case with a specialist, and 67% would contact a laboratory professional. The most useful test utilisation enablers were found to be: interpretive comments (78% of respondents, published guidelines (74%, and a dedicated laboratory phone line (72%. Conclusion: Primary care doctors acknowledge uncertainty with test result interpretation. Potential countermeasures include the addition of patient-specific interpretive comments, the availability of guidelines or algorithms, and a dedicated laboratory phone line. The benefit of enhanced test result interpretation would reduce diagnostic error rates.

  17. INTER LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON

    Science.gov (United States)

    2018-03-26

    data by Instrumentation for Impact  Test , SAE standard J211‐1 [4]. Although the entire curve is collected, the interest of this  project  team  solely...HELMET BLUNT IMPACT TEST METHOD COMPARISON by Tony J. Kayhart Charles A. Hewitt and Jonathan Cyganik March 2018 Final...INTER-LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR

  18. Nodular skin reactions in eyebrow permanent makeup: two case reports and an infection by Mycobacterium haemophilum.

    Science.gov (United States)

    Wollina, Uwe

    2011-09-01

    Permanent makeup is becoming more and more popular. The procedures, however, bear some medical risks. We will describe possible adverse effects of the procedure. This is a report of clinical observations. We report about two women aged 26 and 47 years, who developed nodules with some delay after permanent tattooing the eyebrows. Clinical, histologic, and laboratory investigations revealed a noninfectious granulomatous reaction not responding to topical calcineurin inhibitor but corticosteroids in the younger patient. In the other woman, an infection by Mycobacterium haemophilum could be identified. A triple combination of clarithromycin, ciprofloxacin, and rifampicin succeeded in clearance of the lesions. Adverse reactions after permanent makeup need a medical evaluation to identify health risks and initiate early treatment. © 2011 Wiley Periodicals, Inc.

  19. Potential over request in anemia laboratory tests in primary care in Spain.

    Science.gov (United States)

    Salinas, María; López-Garrigós, Maite; Flores, Emilio; Uris, Joaquín; Leiva-Salinas, Carlos

    2015-07-01

    The aim was to study the inter-practice variability in anemia laboratory tests requested by general practitioners in Spain, to evaluate for a potential requesting inappropriateness. Laboratories from diverse Spanish regions filled out the number of cell blood count, ferritin, folate, iron, transferrin, and vitamin B12 requested by general practitioners during 2012. The number of test requests per 1000 inhabitants and ratios of related tests requests were calculated. The results obtained in hospitals from different areas (urban, rural, or urban-rural), type of management (public or private), and geographic regions were compared. There was a high variability in the number of test requests and ratios of related tests. Cell blood count was over requested in rural areas and in hospitals with private management. Andalucía was the community with the lowest number of iron requests and the lowest folate/vitamin B12 indicator value. Iron and transferrin seemed over requested in some areas; as were folate and ferritin when compared to vitamin B12 and cell blood count, respectively. The differences observed between areas indicate that other factors besides clinical reasons could be behind that variability and emphasize the need to accomplish interventions to improve the appropriate use of anemia laboratory tests.

  20. SENSORY AND CONSUMER TESTING LABORATORY

    Data.gov (United States)

    Federal Laboratory Consortium — These laboratories conduct a wide range of studies to characterize the sensory properties of and consumer responses to foods, beverages, and other consumer products....

  1. ASVCP quality assurance guidelines: external quality assessment and comparative testing for reference and in-clinic laboratories.

    Science.gov (United States)

    Camus, Melinda S; Flatland, Bente; Freeman, Kathleen P; Cruz Cardona, Janice A

    2015-12-01

    The purpose of this document is to educate providers of veterinary laboratory diagnostic testing in any setting about comparative testing. These guidelines will define, explain, and illustrate the importance of a multi-faceted laboratory quality management program which includes comparative testing. The guidelines will provide suggestions for implementation of such testing, including which samples should be tested, frequency of testing, and recommendations for result interpretation. Examples and a list of vendors and manufacturers supplying control materials and services to veterinary laboratories are also included. © 2015 American Society for Veterinary Clinical Pathology.

  2. Analysis and testing of a double armature brushless dc linear motor with NdFeB permanent magnets

    International Nuclear Information System (INIS)

    Filho, A.F.F.

    1998-01-01

    The use of high-energy product NdFeB permanent magnets benefits the design and features of a double armature brushless dc linear motor. As the linear motor is also slotless, its 5 mm airgap requires a source of high flux to overcome the reluctance and produce an adequate amount of force. The linear motor employs a topology that makes use of five permanent magnets to provide excitation flux. The permanent magnets are arranged in such a way that maximises the force the linear motor can deliver. The actuator produces a force up to 86.2 N at an armature current of 4.5 A. However, the topology makes the actuator prone to saturation. It affects the operation point of the permanent magnets, reduces the airgap flux density and the force, and increases flux leakage. To avoid saturation, a flux compensation scheme was conceived. The results are presented and assessed by means of finite element simulation and by experimental results that presented a good agreement. (orig.)

  3. Ice load reducer for dams : laboratory tests

    Energy Technology Data Exchange (ETDEWEB)

    Lupien, R.; Cote, A.; Robert, A. [Institut de Recherche d' Hydro-Quebec, Varennes, PQ (Canada)

    2009-07-01

    Many studies have focused on measuring static ice loads on various hydraulic structures in Canada. This paper discussed a Hydro-Quebec research project whose main purpose was to harmonize the ice thrust value in load combinations for use in general hydraulic works or for specific cases. The objectives of the project were to obtain a better understanding of existing data and to characterize sites and their influence on ice thrust; study the structural mechanisms involved in the generation of ice thrust, their consequences on the structural behaviour of ice and the natural mitigating circumstances that may be offered by ice properties or site operating procedures; and examine the relevance of developing an ice load reducer for works that might not fit the harmonized design value. The paper presented the main research goals and ice load reducer goals, with particular focus on the four pipe samples that were planned, built and tested. The experimental program involved checking the pipe shape behaviour in terms of flexibility-stiffness; maximum deformations; maximum load reduction; permanent deformations; and, ability to shape recovering. The testing also involved examining the strength versus strain rate; creep versus strain rate; and creep capacity under biaxial state of tension and compression. It was concluded that the two phenomena involved in generation of ice thrust, notably thermal expansion and water level changes, had very low strain rates. 8 refs., 2 tabs., 16 figs.

  4. Design and construction of permanent magnetic gears

    DEFF Research Database (Denmark)

    Jørgensen, Frank Thorleif

    /l]. Measurement from this gear has resulted in a measured total torque density of 23 [Nm/l]. Mechanical versions of this gear type are found with total torque density in the 16 to 31 [Nm/l] range. The third and last gear technology that is investigated is a gear that reminds of a planetary gear. Research shows......This thesis deals with design and development of permanent magnetic gears. The goal of this thesis is to develop knowledge and calculation software for magnetic gears. They use strong NdFeB permanent magnets and a new magnetic gear technology, which will be a serious alternative to classical...... mechanical gears. The new magnetic gear will have a high torque density1 relationship –high efficiency and are maintenance free. In this project was manufactured two test gears which is tested and verified with models developed in this project. Present technological status for magnetic gears is introduced...

  5. 75 FR 39954 - Oversight of Laboratory Developed Tests; Public Meeting; Change of Meeting Location

    Science.gov (United States)

    2010-07-13

    ...] Oversight of Laboratory Developed Tests; Public Meeting; Change of Meeting Location AGENCY: Food and Drug... location for the upcoming public meeting entitled ``Oversight of Laboratory Developed Tests.'' A new... the public meeting, FDA is announcing in this notice a new location for the public meeting. II. New...

  6. GESCAL: Quality management automated system for a calibration and test laboratory

    International Nuclear Information System (INIS)

    Manzano de Armas, J.; Valdes Ramos, M.; Morales Monzon, J.A.

    1998-01-01

    GESCAL is a software created to automate all elements composing the quality system in a calibration and test laboratory. It also evaluates quality according to its objectives and policies. This integrated data system decreases considerably the amount of time devoted to manage quality. It is speedier in searching and evaluating information registers thus notably in reducing the workload for laboratory staff

  7. Laboratory tests in support of the MSRE reactive gas removal system

    International Nuclear Information System (INIS)

    Rudolph, J.C.; Del Cul, G.D.; Caja, J.; Toth, L.M.; Williams, D.F.; Thomas, K.S.; Clark, D.E.

    1997-07-01

    The Molten Salt Reactor Experiment (MSRE) at Oak Ridge National Laboratory has been shut down since December 1969, at which time the molten salt mixture of LiF-BeF 2 -ZrF 4 - 233 UF 4 (64.5-30.3-5.0-0.13 mol%) was transferred to fuel salt drain tanks for storage. In the late 1980s, increased radiation in one of the gas lines from the drain tank was attributed to 233 UF 6 . In 1994 two gas samples were withdraw (from a gas line in the Vent House connecting to the drain tanks) and analyzed. Surprisingly, 350 mm Hg of F 2 , 70 mm Hg of UF 6 , and smaller amounts of other gases were found in both of the samples. To remote this gas from above the drain tanks and all of the associated piping, the reactive gas removal system (RGRS) was designed. This report details the laboratory testing of the RGRS, using natural uranium, prior to its implementation at the MSRE facility. The testing was performed to ensure that the equipment functioned properly and was sufficient to perform the task while minimizing exposure to personnel. In addition, the laboratory work provided the research and development effort necessary to maximize the performance of the system. Throughout this work technicians and staff who were to be involved in RGRS operation at the MSRE site worked directly with the research staff in completing the laboratory testing phase. Consequently, at the end of the laboratory work, the personnel who were to be involved in the actual operations had acquired all of the training and experience necessary to continue with the process of reactive gas removal

  8. PIGMI program at the Los Alamos Scientific Laboratory

    International Nuclear Information System (INIS)

    Stovall, J.E.

    1980-09-01

    The PIGMI Program has completed 3-1/2 yr of a project to develop the technology for the optimal pion generator for medical irradiations (PIGMI). The major accomplishments under the program include completion of the injector beam measurements; completion of the 440-MHz radio-frequency (rf) power source; assembly and test of the alternating phase focusing accelerator section; development of the rf-quadrupole (RFQ) beam-dynamics program, PARMTEQ; design, fabrication, assembly, and test of the RFQ accelerator; final decision on low-energy configuration for PIGMI; assembly of the drift-tube linac section of the PIGMI Prototype; completion of sample set of permanent magnet quadrupoles; optimization of the disk-and-washer (DAW) cavity geometry; fabrication of model cavities of the DAW; final decision on DAW support geometry; acquisition of additional laboratory space for the DAW power test; partial assembly of the 1320-MHz rf power source for the DAW test; and pion channel design studies

  9. Automation software for a materials testing laboratory

    Science.gov (United States)

    Mcgaw, Michael A.; Bonacuse, Peter J.

    1990-01-01

    The software environment in use at the NASA-Lewis Research Center's High Temperature Fatigue and Structures Laboratory is reviewed. This software environment is aimed at supporting the tasks involved in performing materials behavior research. The features and capabilities of the approach to specifying a materials test include static and dynamic control mode switching, enabling multimode test control; dynamic alteration of the control waveform based upon events occurring in the response variables; precise control over the nature of both command waveform generation and data acquisition; and the nesting of waveform/data acquisition strategies so that material history dependencies may be explored. To eliminate repetitive tasks in the coventional research process, a communications network software system is established which provides file interchange and remote console capabilities.

  10. Reduction in Unnecessary Clinical Laboratory Testing Through Utilization Management at a US Government Veterans Affairs Hospital.

    Science.gov (United States)

    Konger, Raymond L; Ndekwe, Paul; Jones, Genea; Schmidt, Ronald P; Trey, Marty; Baty, Eric J; Wilhite, Denise; Munshi, Imtiaz A; Sutter, Bradley M; Rao, Maddamsetti; Bashir, Chowdry M

    2016-03-01

    To implement an electronic laboratory utilization management system (laboratory expert system [LES]) to provide safe and effective reductions in unnecessary clinical laboratory testing. The LES is a set of frequency filter subroutines within the Veterans Affairs hospital and laboratory information system that was formulated by an interdisciplinary medical team. Since implementing the LES, total test volume has decreased by a mean of 11.18% per year compared with our pre-LES test volume. This change was not attributable to fluctuations in outpatient visits or inpatient days of care. Laboratory cost savings were estimated at $151,184 and $163,751 for 2012 and 2013, respectively. A significant portion of these cost savings was attributable to reductions in high-volume, large panel testing. No adverse effects on patient care were reported, and mean length of stay for patients remained unchanged. Electronic laboratory utilization systems can effectively reduce unnecessary laboratory testing without compromising patient care. Published by Oxford University Press on behalf of the American Society for Clinical Pathology, 2016. This work is written by US Government employees and is in the public domain in the US.

  11. Development of object permanence in food-storing magpies (Pica pica).

    Science.gov (United States)

    Pollok, B; Prior, H; Güntürkün, O

    2000-06-01

    The development of object permanence was investigated in black-billed magpies (Pica pica), a food-storing passerine bird. The authors tested the hypothesis that food-storing development should be correlated with object-permanence development and that specific stages of object permanence should be achieved before magpies become independent. As predicted, Piagetian Stages 4 and 5 were reached before independence was achieved, and the ability to represent a fully hidden object (Piagetian Stage 4) emerged by the age when magpies begin to retrieve food. Contrary to psittacine birds and humans, but as in dogs and cats, no "A-not-B error" occurred. Although magpies also mastered 5 of 6 invisible displacement tasks, evidence of Piagetian Stage 6 competence was ambiguous.

  12. Use of Proficiency Testing as a Tool to Improve Quality in Microbiology Laboratories

    OpenAIRE

    Stang, Heather L.; Anderson, Nancy L.

    2013-01-01

    Proficiency testing (PT) is a valuable tool for assessing laboratory performance and verifying the accuracy and reliability of test results. Participation is required by the Clinical Laboratory Improvement Amendments (CLIA) of 1988 for each of the microbiology subspecialties (bacteriology, mycobacteriology, mycology, parasitology, and virology), and the regulations include specific PT requirements for each subspecialty. To determine the use and perceived value of PT beyond meeting CLIA requir...

  13. Evaluating performance in sweat testing in medical biochemistry laboratories in Croatia.

    Science.gov (United States)

    Aralica, Merica; Krleza, Jasna Lenicek

    2017-02-15

    Sweat test has a diagnostic role in evaluation of cystic fibrosis. Its performance includes sweat stimulation, collection and analysis. All listed may be sources of inconsistencies in everyday practice. The aim of this study was an evaluation of external quality assessment (EQA) of sweat chloride measurement including sweat test performance in medical biochemistry laboratories in Croatia. EQA for sweat chloride measurement was provided by Croatian Centre for Quality Assessment in Laboratory Medicine (CROQALM) in five consecutive exercises to medical biochemistry laboratories (MBL) that offered sweat testing. A questionnaire regarding all phases of testing was mailed to involved MBL (N = 10). Survey results were compared to current guidelines for sweat test performance. Reported results of EQA in 2015 exercises showed coefficients of variation (CV) from 28.9%, 29.0% to 35.3%, respectively. An introduction of uniform sweat chloride measurement protocol resulted in CV of 15.5% and 14.7% reported in following two exercises in 2016. All MBL included in this study replied to the questionnaire. Results reported by MBL indicated: lack of patient information policy (7/10), use of unacceptable electrodes (6/9), misuse of minimum of acceptable sweat weight (6/9), lack of internal quality assessment (5/9) and recommended reference ranges (5/9 and 4/9). Agreements to guidelines were found in approach to unsuitable patients (9/10) and sweat collection (8/9). Presented results indicate major weak points of current practice in sweat test performance in Croatian MBL and stress the need for its standardization on a national level.

  14. Mars Science Laboratory Flight Software Internal Testing

    Science.gov (United States)

    Jones, Justin D.; Lam, Danny

    2011-01-01

    The Mars Science Laboratory (MSL) team is sending the rover, Curiosity, to Mars, and therefore is physically and technically complex. During my stay, I have assisted the MSL Flight Software (FSW) team in implementing functional test scripts to ensure that the FSW performs to the best of its abilities. There are a large number of FSW requirements that have been written up for implementation; however I have only been assigned a few sections of these requirements. There are many stages within testing; one of the early stages is FSW Internal Testing (FIT). The FIT team can accomplish this with simulation software and the MSL Test Automation Kit (MTAK). MTAK has the ability to integrate with the Software Simulation Equipment (SSE) and the Mission Processing and Control System (MPCS) software which makes it a powerful tool within the MSL FSW development process. The MSL team must ensure that the rover accomplishes all stages of the mission successfully. Due to the natural complexity of this project there is a strong emphasis on testing, as failure is not an option. The entire mission could be jeopardized if something is overlooked.

  15. Hanford Site Permanent Isolation Surface Barrier Development Program: Fiscal year 1992 and 1993 highlights

    International Nuclear Information System (INIS)

    Cadwell, L.L.; Link, S.O.; Gee, G.W.

    1993-09-01

    The Hanford Site Permanent Isolation Surface Barrier Development Program was jointly developed by the Pacific Northwest Laboratory and Westinghouse Hanford Company to design and test an earthen cover system that can be used to inhibit water infiltration; plant, animal, and human intrusion; and wind and water erosion. Kaiser Engineers Hanford Company provided engineering design support for the program. Work on barrier design has been under way at Hanford for nearly 10 years. The comprehensive development of a long-term barrier, formerly the Hanford Site Protective Barrier Development Program, was initiated in FY 1986, and a general field-tested design is expected to be completed by FY 1998. Highlights of efforts in FY 1992 and FY 1993 included the resumption of field testing, the completion of the prototype barrier design, and the convening of an external peer review panel, which met twice with the barrier development team. The review panel provided helpful guidance on current and future barrier development activities, while commending the program for its significant technical contributions to innovative barrier technology development

  16. The quality and scope of information provided by medical laboratories to patients before laboratory testing: Survey of the Working Group for Patient Preparation of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    Science.gov (United States)

    Nikolac, Nora; Simundic, Ana-Maria; Kackov, Sanja; Serdar, Tihana; Dorotic, Adrijana; Fumic, Ksenija; Gudasic-Vrdoljak, Jelena; Klenkar, Kornelija; Sambunjak, Jadranka; Vidranski, Valentina

    2015-10-23

    The aim of this work was to evaluate to what extent the scope and content of information provided to patients is standardized across medical biochemistry laboratories in Croatia. Two on-line self-report surveys were sent out: Survey A regarding attitudes on importance of patient preparation and Survey B on the contents of patient preparation instructions. 13/118 laboratories (11%) do not provide written instructions to patients on how to prepare for laboratory testing, and 36 (40%) do not include information about water intake in their instructions. Only half of laboratories provide instructions for prostate-specific antigen (53.8%), female sex hormones (53.7%) and therapeutic drug monitoring (TDM) (52.5%). Inadequate information about fasting status (55.0%) and 24 hour urine collection (77.9%) were frequent errors with high severity and were associated with the greatest potential to cause patient harm. Laboratory professionals in Croatia have a positive attitude towards the importance of patient preparation for laboratory testing. However, the information for laboratory testing is not standardized and frequently lacks guidance for tests related to TDM, coagulation and endocrinology. This study highlights the need for standardized, updated and evidence-based recommendations for patient preparation in order to minimize the risk for patients. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. CERTS Microgrid Laboratory Test Bed - PIER Final Project Report

    Energy Technology Data Exchange (ETDEWEB)

    Eto, Joseph H.; Eto, Joseph H.; Lasseter, Robert; Schenkman, Ben; Klapp, Dave; Linton, Ed; Hurtado, Hector; Roy, Jean; Lewis, Nancy Jo; Stevens, John; Volkommer, Harry

    2008-07-25

    The objective of the CERTS Microgrid Laboratory Test Bed project was to enhance the ease of integrating small energy sources into a microgrid. The project accomplished this objective by developing and demonstrating three advanced techniques, collectively referred to as the CERTS Microgrid concept, that significantly reduce the level of custom field engineering needed to operate microgrids consisting of small generating sources. The techniques comprising the CERTS Microgrid concept are: 1) a method for effecting automatic and seamless transitions between grid-connected and islanded modes of operation; 2) an approach to electrical protection within the microgrid that does not depend on high fault currents; and 3) a method for microgrid control that achieves voltage and frequency stability under islanded conditions without requiring high-speed communications. The techniques were demonstrated at a full-scale test bed built near Columbus, Ohio and operated by American Electric Power. The testing fully confirmed earlier research that had been conducted initially through analytical simulations, then through laboratory emulations, and finally through factory acceptance testing of individual microgrid components. The islanding and resychronization method met all Institute of Electrical and Electronics Engineers 1547 and power quality requirements. The electrical protections system was able to distinguish between normal and faulted operation. The controls were found to be robust and under all conditions, including difficult motor starts. The results from these test are expected to lead to additional testing of enhancements to the basic techniques at the test bed to improve the business case for microgrid technologies, as well to field demonstrations involving microgrids that involve one or mroe of the CERTS Microgrid concepts.

  18. The cycloid Permanent Magnetic Gear

    DEFF Research Database (Denmark)

    Rasmussen, Peter Omand; Andersen, Torben Ole; Jørgensen, Frank T.

    2008-01-01

    This paper presents a new permanent-magnet gear based on the cycloid gearing principle. which normally is characterized by an extreme torque density and a very high gearing ratio. An initial design of the proposed magnetic gear was designed, analyzed, and optimized with an analytical model...... regarding torque density. The results were promising as compared to other high-performance magnetic-gear designs. A test model was constructed to verify the analytical model....

  19. Laboratory competence evaluation through proficiency testing - mycotoxins in food

    Directory of Open Access Journals (Sweden)

    Torović Ljilja D.

    2017-01-01

    Full Text Available Laboratory for analysis of mycotoxins in food at the Institute of Public Health of Vojvodina (Novi Sad, Serbia participated in 15 proficiency testing schemes in period 2012-2016, comprising 22 determinations of regulated mycotoxins: aflatoxins B1, B2, G1, G2 and M1, ochratoxin A, deoxynivalenone, zearalenone, fumonisins and patulin, in different food commodities: wheat, corn, barley, breakfast cereals, infant food, milk, wine and fruit juice. Analyses were carried out by high performance liquid chromatography with ultraviolet (patulin, deoxynivalenol or fluorescence detection (aflatoxin M1, ochratoxin A, zearalenone using o-phthalaldehyde precolumn derivatization (fumonisins or UV postcolumn derivatization (aflatoxins B1, B2, G1, G2, following clean-up on immunoaffinity columns with specific antibodies, except in case of patulin when solvent extraction and solid-phase C-18 clean-up were used. Laboratory performance assessed in terms of z scores showed all satisfactory results. In depth evaluation revealed following distribution of z scores (absolute values: 59.1% up to 0.5, 36.4% between 0.5 and 1.0, and 4.5% above 1.0. Analysis of trends performed for multiple determinations of individual mycotoxins showed several changes of z score to better or worse rank. Overall assessment of the performance in proficiency testing demonstrated laboratory competence for analysis of mycotoxins in food.

  20. Laboratory rock mechanics testing manual. Public draft

    Energy Technology Data Exchange (ETDEWEB)

    Shuri, F S; Cooper, J D; Hamill, M L

    1981-10-01

    Standardized laboratory rock mechanics testing procedures have been prepared for use in the National Terminal Waste Storage Program. The procedures emphasize equipment performance specifications, documentation and reporting, and Quality Assurance acceptance criteria. Sufficient theoretical background is included to allow the user to perform the necessary data reduction. These procedures incorporate existing standards when possible, otherwise they represent the current state-of-the-art. Maximum flexibility in equipment design has been incorporated to allow use of this manual by existing groups and to encourage future improvements.

  1. Diagnostics Systems for Permanent Hall Thrusters Development

    Science.gov (United States)

    Ferreira, Jose Leonardo; Soares Ferreira, Ivan; Santos, Jean; Miranda, Rodrigo; Possa, M. Gabriela

    This work describes the development of Permanent Magnet Hall Effect Plasma Thruster (PHALL) and its diagnostic systems at The Plasma Physics Laboratory of University of Brasilia. The project consists on the construction and characterization of plasma propulsion engines based on the Hall Effect. Electric thrusters have been employed in over 220 successful space missions. Two types stand out: the Hall-Effect Thruster (HET) and the Gridded Ion Engine (GIE). The first, which we deal with in this project, has the advantage of greater simplicity of operation, a smaller weight for the propulsion subsystem and a longer shelf life. It can operate in two configurations: magnetic layer and anode layer, the difference between the two lying in the positioning of the anode inside the plasma channel. A Hall-Effect Thruster-HET is a type of plasma thruster in which the propellant gas is ionized and accelerated by a magneto hydrodynamic effect combined with electrostatic ion acceleration. So the essential operating principle of the HET is that it uses a J x B force and an electrostatic potential to accelerate ions up to high speeds. In a HET, the attractive negative charge is provided by electrons at the open end of the Thruster instead of a grid, as in the case of the electrostatic ion thrusters. A strong radial magnetic field is used to hold the electrons in place, with the combination of the magnetic field and the electrostatic potential force generating a fast circulating electron current, the Hall current, around the axis of the Thruster, mainly composed by drifting electrons in an ion plasma background. Only a slow axial drift towards the anode occurs. The main attractive features of the Hall-Effect Thruster are its simple design and operating principles. Most of the Hall-Effect Thrusters use electromagnet coils to produce the main magnetic field responsible for plasma generation and acceleration. In this paper we present a different new concept, a Permanent Magnet Hall

  2. Geographically distributed hybrid testing & collaboration between geotechnical centrifuge and structures laboratories

    Science.gov (United States)

    Ojaghi, Mobin; Martínez, Ignacio Lamata; Dietz, Matt S.; Williams, Martin S.; Blakeborough, Anthony; Crewe, Adam J.; Taylor, Colin A.; Madabhushi, S. P. Gopal; Haigh, Stuart K.

    2018-01-01

    Distributed Hybrid Testing (DHT) is an experimental technique designed to capitalise on advances in modern networking infrastructure to overcome traditional laboratory capacity limitations. By coupling the heterogeneous test apparatus and computational resources of geographically distributed laboratories, DHT provides the means to take on complex, multi-disciplinary challenges with new forms of communication and collaboration. To introduce the opportunity and practicability afforded by DHT, here an exemplar multi-site test is addressed in which a dedicated fibre network and suite of custom software is used to connect the geotechnical centrifuge at the University of Cambridge with a variety of structural dynamics loading apparatus at the University of Oxford and the University of Bristol. While centrifuge time-scaling prevents real-time rates of loading in this test, such experiments may be used to gain valuable insights into physical phenomena, test procedure and accuracy. These and other related experiments have led to the development of the real-time DHT technique and the creation of a flexible framework that aims to facilitate future distributed tests within the UK and beyond. As a further example, a real-time DHT experiment between structural labs using this framework for testing across the Internet is also presented.

  3. Modification and testing of the Sandia Laboratories Livermore tritium decontamination systems

    International Nuclear Information System (INIS)

    Gildea, P.D.; Birnbaum, H.G.; Wall, W.R.

    1978-08-01

    Sandia Laboratories, Livermore, has put into operation a new facility, the Tritium Research Laboratory. The laboratory incorporates containment and cleanup facilities such that any tritium accidentally released is captured rather than vented to the atmosphere. This containment is achieved with hermetically sealed glove boxes that are connected on demand by manifolds to two central decontamination systems called the Gas Purification System (GPS) and the Vacuum Effluent Recovery System (VERS). The primary function of the GPS is to remove tritium and tritiated water vapor from the glove box atmosphere. The primary function of the VERS is to decontaminate the gas exhausted from the glove box pressure control systems and vacuum pumps in the building before venting the gas to the stack. Both of these systems are designed to remove tritium to the few parts per billion range. Acceptance tests at the manufacturer's plant and preoperational testing at Livermore demonstrated that the systems met their design specifications. After preoperational testing the Gas Purification System was modified to enhance the safety of maintanance operations. Both the Gas Purification System and the Vacuum Effluent Recovery System were performance tested with tritium. Results show that concentraion reduction factors (ratio of inlet to exhaust concentrations) much in excess of 1000 per pass have been achieved for both systems at inlet concentrations of 1 ppM or less

  4. Modification and testing of the Sandia Laboratories Livermore tritium decontamination systems

    International Nuclear Information System (INIS)

    Gildea, P.D.; Birnbaum, H.G.; Wall, W.R.

    1979-01-01

    Sandia Laboratories, Livermore, has put into operation a new facility, the Tritium Research Laboratory. The laboratory incorporates containment and cleanup facilities such that any tritium accidentally released is captured rather than vented to the atmosphere. This containment is achieved with hermetically sealed glove boxes that are connected on demand by manifolds to two central decontamination systems called the Gas Purification System (GPS) and the Vacuum Effluent Recovery System (VERS). The primary function of the GPS is to remove tritium and tritiated water vapor from the glove box atmosphere. The primary function of the VERS is to decontaminate the gas exhausted from the glove box pressure control systems and vacuum pumps in the building before venting the gas to the stack. Both of these systems are designed to remove tritium to the few parts per billion range. Acceptance tests at the manufacturer's plant and preoperational testing at Livermore demonstrated that the systems met their design specifications. After preoperational testing the Gas Purification System was modified to enhance the safety of maintanance operations. Both the Gas Purification System and the Vacuum Effluent Recovery System were performance tested with tritium. Results show that concentration reduction factors (ratio of inlet to exhaust concentrations) much in excess of 1000 per pass have been achieved for both systems at inlet concentrations of 1 ppM or less

  5. The financial imperative of physicians to control demand of laboratory testing.

    LENUS (Irish Health Repository)

    Murphy, R K J

    2012-02-01

    It is an integral component of doctor\\'s duty of care to understand the significant impact laboratory testing has on the expense an ultimate quality of healthcare patients receive, yet the costs of these tests are poorly perceived. Utilising semi-structured interviews and questionnaires, we assessed surgeon\\'s perceived costs of two commonly encountered clinical scenarios requiring out of hours laboratory testing. Of the 35 participants only 23.3% (n = 7) accurately estimated the overall cost. The most expensive test was "Type and Screen" at Euro 83, with 77.3% (n = 17) underestimating the cost. Non-consultant hospital doctors qualified for 3 years were more likely to underestimate on-call costs (p = 0.042). It is of utmost importance to improve the knowledge of all surgeons of the financial implications of investigations. Through education we can potentially reduce un-warranted costs and fulfill our duty of care in the most cost efficient manner.

  6. Laboratory evaluation of immunochromatographic rapid diagnostic tests for cholera in Haiti.

    Directory of Open Access Journals (Sweden)

    Wilfredo R Matias

    Full Text Available Rapid diagnostic tests (RDT for cholera are promising tools for detecting cholera in areas with limited laboratory infrastructure. However, evidence on the characteristics of the many available RDTs is scarce, and their use has been limited by suboptimal performance. We evaluated the performance characteristics of three cholera RDTs from Span Diagnostics, Artron Laboratories, and Standard Diagnostics in a regional laboratory in Haiti.We retrospectively reviewed records from May 2014 to October 2015 of a laboratory-based surveillance program for Vibrio cholerae at Hôpital Saint-Nicolas in Saint-Marc, Haiti. We compared the results of 511 Crystal VC, 129 Artron and 451 SD Bioline RDTs to bacterial culture as the gold standard. Of 905 cultures, 477 (52.7% were positive for V. cholerae O1, of which 27.7% were serotype Inaba. No cultures grew V. cholerae O139. Sensitivity and specificity of Crystal VC were 98.6% (95%CI: 96.5%-99.6% and 71.1% (95%CI: 64.7%-76.9%, respectively. Artron demonstrated a sensitivity of 98.6% (95%CI: 92.7%-100% and specificity of 69.1% (95%CI: 55.2%-80.9%. SD Bioline demonstrated a sensitivity of 81.1% (95%CI: 75.6%-85.8% and specificity of 92.8% (95%CI: 88.4%-95.9%. Crystal VC and Artron frequently showed false positive O139 bands, whereas none were seen with SD Bioline.There is significant variation in the performance of different cholera diagnostic RDTs. Artron and Crystal VC RDTs have high sensitivity and low specificity, while SD Bioline RDT has low to moderate sensitivity and high specificity when performed by laboratory technicians in Haiti. Study limitations included its retrospective design. The suboptimal characteristics of these tests limit their use as clinical point-of-care tests; however, they may be useful in outbreak response, surveillance, and research in resource-limited settings.

  7. Mounted Smartphones as Measurement and Control Platforms for Motor-Based Laboratory Test-Beds

    Directory of Open Access Journals (Sweden)

    Jared A. Frank

    2016-08-01

    Full Text Available Laboratory education in science and engineering often entails the use of test-beds equipped with costly peripherals for sensing, acquisition, storage, processing, and control of physical behavior. However, costly peripherals are no longer necessary to obtain precise measurements and achieve stable feedback control of test-beds. With smartphones performing diverse sensing and processing tasks, this study examines the feasibility of mounting smartphones directly to test-beds to exploit their embedded hardware and software in the measurement and control of the test-beds. This approach is a first step towards replacing laboratory-grade peripherals with more compact and affordable smartphone-based platforms, whose interactive user interfaces can engender wider participation and engagement from learners. Demonstrative cases are presented in which the sensing, computation, control, and user interaction with three motor-based test-beds are handled by a mounted smartphone. Results of experiments and simulations are used to validate the feasibility of mounted smartphones as measurement and feedback control platforms for motor-based laboratory test-beds, report the measurement precision and closed-loop performance achieved with such platforms, and address challenges in the development of platforms to maintain system stability.

  8. Mounted Smartphones as Measurement and Control Platforms for Motor-Based Laboratory Test-Beds.

    Science.gov (United States)

    Frank, Jared A; Brill, Anthony; Kapila, Vikram

    2016-08-20

    Laboratory education in science and engineering often entails the use of test-beds equipped with costly peripherals for sensing, acquisition, storage, processing, and control of physical behavior. However, costly peripherals are no longer necessary to obtain precise measurements and achieve stable feedback control of test-beds. With smartphones performing diverse sensing and processing tasks, this study examines the feasibility of mounting smartphones directly to test-beds to exploit their embedded hardware and software in the measurement and control of the test-beds. This approach is a first step towards replacing laboratory-grade peripherals with more compact and affordable smartphone-based platforms, whose interactive user interfaces can engender wider participation and engagement from learners. Demonstrative cases are presented in which the sensing, computation, control, and user interaction with three motor-based test-beds are handled by a mounted smartphone. Results of experiments and simulations are used to validate the feasibility of mounted smartphones as measurement and feedback control platforms for motor-based laboratory test-beds, report the measurement precision and closed-loop performance achieved with such platforms, and address challenges in the development of platforms to maintain system stability.

  9. Comparison of basic laboratory test results with more sophisticated laboratory and in-situ tests methods on soils in southeastern Wisconsin : final report, March 21, 2009.

    Science.gov (United States)

    2009-03-21

    This study investigates all of the generated soils data in an attempt to use the more 'routine' laboratory tests to determine geotechnical design parameters (such as phiangle, cohesion, wet unit weight, unconfined compression, consolidation character...

  10. Testing the performance of microbiological safety cabinets used in microbiology laboratories in South Korea.

    Science.gov (United States)

    Hwang, S H; Yi, T W; Cho, K H; Lee, I M; Yoon, C S

    2011-09-01

    To test a performance of the microbiological safety cabinets (MSCs) according to the type of MSCs in microbial laboratories. Tests were carried out to assess the performance of 31 MSCs in 14 different facilities, including six different biological test laboratories in six hospitals and eight different laboratories in three universities. The following tests were performed on the MSCs: the downflow test, intake velocity test, high-efficiency particulate air filter leak test and the airflow smoke pattern test. These performance tests were carried out in accordance with the standard procedures. Only 23% of Class II A1 (8), A2 (19) and unknown MSCs (4) passed these performance tests. The main reasons for the failure of MSCs were inappropriate intake velocity (65%), leakage in the HEPA filter sealing (50%), unbalanced airflow smoke pattern in the cabinets (39%) and inappropriate downflow (27%). This study showed that routine checks of MSCs are important to detect and strengthen the weak spots that frequently develop, as observed during the evaluation of the MSCs of various institutions. Routine evaluation and maintenance of MSCs are critical for optimizing performance. © 2011 The Authors. Letters in Applied Microbiology © 2011 The Society for Applied Microbiology.

  11. Laboratory tests of headache disorders - Dawn of a new era?

    DEFF Research Database (Denmark)

    Schytz, Henrik Winther; Olesen, Jes

    2016-01-01

    secondary headaches. Background In this narrative review we present and discuss published tests that might be useful in phenotyping and/or diagnosis of long-lasting headache disorders such as migraine, tension-type headache, trigeminal autonomic cephalalgias, trigeminal neuralgia and persisting secondary...... headaches. Aim The palpometer test, quantitative sensory testing, nociceptive blink reflex and autonomic tests may be valuable to phenotype and/or diagnose subforms of migraine, tension-type headache, cluster headache, trigeminal neuralgia and medication-overuse headache. Provocation tests with glyceryl...... if well-reputed tertiary headache centers commence developing and implementing laboratory tests in order to improve the classification and treatment of headache patients....

  12. 75 FR 9953 - Definition and Requirements for a Nationally Recognized Testing Laboratory (NRTL); Extension of...

    Science.gov (United States)

    2010-03-04

    ...] Definition and Requirements for a Nationally Recognized Testing Laboratory (NRTL); Extension of the Office of Management and Budget's (OMB) Approval of Information Collection (Paperwork) Requirements AGENCY... its Regulation on the Definition and Requirements for a Nationally Recognized Testing Laboratory (29...

  13. Multipactor Mitigation in Coaxial Lines by Means of Permanent Magnets

    CERN Document Server

    Gonzalez-Iglesias, D; Anza, S; Vague, J; Gimeno, B; Boria, V E; Raboso, D; Vicente, C; Gil, J; Caspers, F; Conde, L

    2014-01-01

    The main aim of this paper is the analysis of the feasibility of employing permanent magnets for the multipactor mitigation in a coaxial waveguide. First, the study of a coaxial line immersed in a uniform axial magnetic field shows that multipactor can be suppressed at any RF frequency if the external magnetic field is strong enough. Both theoretical simulations and experimental tests validate this statement. Next, multipactor breakdown of a coaxial line immersed in a hollow cylindrical permanent magnet is analyzed. Numerical simulations show that multipactor can be suppressed in a certain RF frequency range. The performed experimental test campaign demonstrates the capability of the magnet to avoid the multipactor electron multiplication process.

  14. Permanent deformation behavior of naturally occurring bituminous sands

    CSIR Research Space (South Africa)

    Anochie-Boateng, Joseph

    2008-01-01

    Full Text Available and mining equipment at two different load pulse durations or loading frequencies (related to field-trafficking speeds). Both the test data and axial permanent strain models developed in the form of power functions of the number of repeated load applications...

  15. Variable-field permanent-magnet quadrupole for the SSC

    International Nuclear Information System (INIS)

    Barlow, D.B.; Kraus, R.H. Jr.; Martinez, R.P.; Meyer, R.E.

    1994-01-01

    A set of compact variable-field permanent-magnet quadrupoles have been designed, fabricated, and tested for use in the SSC linac matching section. The quadrupoles have 24 mm-diameter apertures and 40 mm-long poles. The hybrid (permanent-magnet and iron) design, uses a fixed core of magnet material (NdFeB) and iron (C-1006) surrounded by a rotating ring of the same magnet material and iron. The quadrupole gradient-length product can be smoothly varied from a minimum of 0.7 T up to a maximum of 4.3 T by a 90 degree rotation of the outer ring of iron and magnet material

  16. Variable-field permanent magnet quadrupole for the SSC

    International Nuclear Information System (INIS)

    Barlow, D.B.; Kraus, R.H. Jr.; Martinez, R.P.; Meyer, R.E.

    1993-01-01

    A set of compact variable-field permanent-magnet quadrupoles have been designed, fabricated, and tested for use In the SSC linac matching section. The quadrupoles have 24 mm-diameter apertures and 40 mm-long poles. The hybrid (permanent-magnet and iron) design, uses a fixed core of magnet material (NdFeB) and iron (C-1006) surrounded by a rotating ring of the same magnet material and iron. The quadrupole gradient-length product can be smoothly varied from a minimum of 0.7 T up to a maximum, of 4.3 T by a 90 degrees rotation of the outer ring of iron and magnet material

  17. [Revolution of the health care delivery system and its impacts on laboratory testing in the United States].

    Science.gov (United States)

    Takemura, Y; Ishibashi, M

    2000-02-01

    Failure to slow the exponential growth of total health care expenditures in the United States through the government policies resulted in a rapid and progressive penetration of managed care organizations(MCOs) in the early 1990s. Diagnostic testing is viewed as a "commodity" rather than a medical service under the managed care environment. Traditional hospital-based laboratories are placed in a downward spiral with the advent of managed care era. A massive reduction of in-house testing resulted from shorter lengths of patients' hospital stay and a marked decrease in admission under the dominance of managed care urges them to develop strategies for restoring tests deprived by the managed care-associated new businesses: consolidation and networking, participation in the outreach-testing market, and point-of-care/satellite laboratory testing in non-traditional, ambulatory settings are major strategies for survival of hospital laboratories. A number of physicians' office laboratories(POLs) have been closed owing to regulatory restrictions imposed by the Clinical Laboratory Improvement Amendments of 1988(CLIA '88), and to the expanded penetration of MCOs which limit reimbursement to a very few in-house procedures. It seems likely that POLs and hospital laboratories continue to reduce test volumes, while commercial reference laboratories(CRLs) gain more tests through contracting with MCOs. In the current stream of managed care dominance in the United States, clinical laboratories are changing their basic operation focus and mission in response to the aggressively changing landscape. Traditional laboratories which are unwilling to adapt themselves to the new environment will not survive in this country.

  18. Proficiency Testing Activities of Frequency Calibration Laboratories in Taiwan, 2009

    Science.gov (United States)

    2009-11-01

    cht.com.tw Abstract In order to meet the requirements of ISO 17025 and the demand of TAF (Taiwan Accreditation Foundation) for calibration inter... IEC 17025 General requirements for the competence of testing and calibration laboratories. The proficiency testing results are then important...on-site evaluation, an assessment team is organized to examine the technical competence of the labs and their compliance with the requirements of ISO

  19. Testing painted wood : past practices at the Forest Products Laboratory and recommendations for future research

    Science.gov (United States)

    R. Sam Williams

    2009-01-01

    A brief history of paint research at the Forest Products Laboratory (FPL) in Madison, Wisconsin, sets the stage for a discussion of testing paint on wood and wood products. Tests include laboratory and outdoor tests, and I discuss them in terms of several degradation mechanisms (loss of gloss and fading, mildew growth, extractives bleed, and cracking, flaking, and...

  20. Permanent magnets including undulators and wigglers

    CERN Document Server

    Bahrdt, J

    2010-01-01

    After a few historic remarks on magnetic materials we introduce the basic definitions related to permanent magnets. The magnetic properties of the most common materials are reviewed and the production processes are described. Measurement techniques for the characterization of macroscopic and microscopic properties of permanent magnets are presented. Field simulation techniques for permanent magnet devices are discussed. Today, permanent magnets are used in many fields. This article concentrates on the applications of permanent magnets in accelerators starting from dipoles and quadrupoles on to wigglers and undulators.

  1. Object permanence in the Goffin cockatoo (Cacatua goffini).

    Science.gov (United States)

    Auersperg, Alice M I; Szabo, Birgit; von Bayern, Auguste M P; Bugnyar, Thomas

    2014-02-01

    The ability to represent hidden objects plays an important role in the survival of many species. In order to provide an inclusive synopsis of the current benchmark tasks used to test object permanence in animals for a psittacine representative, we tested eight Goffin cockatoos (Cacatua goffini) on Stages 3-6 of Piagetian object permanence as well as derivations of spatial transposition, rotation, and translocation tasks. Subjects instantly solved visible displacement 3b and 4a but showed an extended plateau for solving Stage 5a at a very late age (10 months). Subjects readily solved most invisible displacement tasks including double hidings and four angles (90°, 180°, 270°, and 360°) of rotation and translocations at high performance levels, although Piagetian Stage 6 invisible displacement tasks caused more difficulties for the animals than transposition, rotations, and translocation tasks. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  2. Collaborative Testing in Practical Laboratories: An Effective Teaching-Learning Method in Histology.

    Science.gov (United States)

    Guo, Yuping; Li, Enzhong

    2016-01-01

    This article presents an experimental teaching and learning program used in histology with first-year students in the second term in the Faculty of Biology at Huanghuai University, China. Eighty-six students were divided randomly into two groups (n=43 per group). Tests were conducted at the end of each practical laboratory (10 laboratories in total) in which collaborative testing was used in the experimental group and traditional testing in the control group. To assess achievement, a final examination in histology was carried out at the end of the course. To determine students' attitude to the teaching styles, a questionnaire survey was conducted at the end of the term. Results showed that students preferred the collaborative testing format. In the experimental group, students' scores were significantly higher than those of students in the control group in final examinations. These findings indicate that collaborative testing enhances student learning and understanding of the material taught, and suggest that collaborative testing is an effective teaching-learning method in histology.

  3. Real-time laboratory exercises to test contingency plans for classical swine fever: experiences from two national laboratories.

    Science.gov (United States)

    Koenen, F; Uttenthal, A; Meindl-Böhmer, A

    2007-12-01

    In order to adequately and efficiently handle outbreaks of contagious diseases such as classical swine fever (CSF), foot and mouth disease or highly pathogenic avian influenza, competent authorities and the laboratories involved have to be well prepared and must be in possession of functioning contingency plans. These plans should ensure that in the event of an outbreak access to facilities, equipment, resources, trained personnel, and all other facilities needed for the rapid and efficient eradication of the outbreak is guaranteed, and that the procedures to follow are well rehearsed. It is essential that these plans are established during 'peace-time' and are reviewed regularly. This paper provides suggestions on how to perform laboratory exercises to test preparedness and describes the experiences of two national reference laboratories for CSF. The major lesson learnt was the importance of a well-documented laboratory contingency plan. The major pitfalls encountered were shortage of space, difficulties in guaranteeing biosecurity and sufficient supplies of sterile equipment and consumables. The need for a standardised laboratory information management system, that is used by all those involved in order to reduce the administrative load, is also discussed.

  4. From laboratory corrosion tests to a corrosion lifetime for wood fasteners : progress and challenges

    Science.gov (United States)

    Samuel L. Zelinka; Dominique Derome; Samuel V. Glass

    2010-01-01

    Determining a “corrosion-lifetime” for fasteners embedded in wood treated with recently adopted preservative systems depends upon successfully relating results of laboratory tests to in-service conditions. In contrast to laboratory tests where metal is embedded in wood at constant temperature and moisture content, the in-service temperature and moisture content of wood...

  5. Laboratory tests on dark energy

    International Nuclear Information System (INIS)

    Beck, Christian

    2006-01-01

    The physical nature of the currently observed dark energy in the universe is completely unclear, and many different theoretical models co-exist. Nevertheless, if dark energy is produced by vacuum fluctuations then there is a chance to probe some of its properties by simple laboratory tests based on Josephson junctions. These electronic devices can be used to perform 'vacuum fluctuation spectroscopy', by directly measuring a noise spectrum induced by vacuum fluctuations. One would expect to see a cutoff near 1.7 THz in the measured power spectrum, provided the new physics underlying dark energy couples to electric charge. The effect exploited by the Josephson junction is a subtile nonlinear mixing effect and has nothing to do with the Casimir effect or other effects based on van der Waals forces. A Josephson experiment of the suggested type will now be built, and we should know the result within the next 3 years

  6. Marxism as permanent revolution

    NARCIS (Netherlands)

    van Ree, E.

    2013-01-01

    This article argues that the 'permanent revolution' represented the dominant element in Karl Marx and Friedrich Engels' political discourse, and that it tended to overrule considerations encapsulated in 'historical materialism'. In Marx and Engels's understanding, permanent revolution did not

  7. Estrogen and progesterone receptor testing in breast carcinoma: concordance of results between local and reference laboratories in Brazil

    Directory of Open Access Journals (Sweden)

    Sheila Cristina Lordelo Wludarski

    Full Text Available CONTEXT AND OBJECTIVE: Breast cancer accounts for approximately one quarter of all cancers in females. Estrogen and progesterone receptor testing has become an essential part of the clinical evaluation of breast carcinoma patients, and accurate results are critical in identifying patients who may benefit from hormone therapy. The present study had the aim of investigating the concordance of the results from hormone receptor tests between a reference laboratory and local (or community laboratories in Brazil. DESIGN AND SETTING: Retrospective study at a reference pathology laboratory. METHODS: The concordance in the results from hormone receptor tests between a reference laboratory and 146 local laboratories in Brazil was compared in relation to 500 invasive breast carcinoma cases, using immunohistochemistry. RESULTS: There was concordance in 89.4% (447/500 cases and 85.0% (425/500 cases of the results from estrogen (κ = 0.744, P < 0.001 and progesterone (κ = 0.688, P < 0.001 receptor tests, respectively, between local and reference laboratories. This was similar to findings in other countries. The false negative rates from estrogen and progesterone receptor tests in local laboratories were 8.7% and 14.4%, respectively. The false positive rates from estrogen and progesterone receptor tests in local laboratories were 15.5% and 16.0%, respectively. CONCLUSION: Technical and result interpretation issues may explain most of the discordances in hormone receptor testing in local laboratories. Validation of estrogen and progesterone receptor tests at local laboratories, with rigorous quality control measures, is strongly recommended in order to avoid erroneous treatment of breast cancer patients.

  8. Object permanence and working memory in cats (Felis catus).

    Science.gov (United States)

    Goulet, S; Doré, F Y; Rousseau, R

    1994-10-01

    Cats (Felis catus) find an object when it is visibly moved behind a succession of screens. However, when the object is moved behind a container and is invisibly transferred from the container to the back of a screen, cats try to find the object at or near the container rather than at the true hiding place. Four experiments were conducted to study search behavior and working memory in visible and invisible displacement tests of object permanence. Experiment 1 compared performance in single and in double visible displacement trials. Experiment 2 analyzed search behavior in invisible displacement tests and in analogs using a transparent container. Experiments 3 and 4 tested predictions made from Experiment 1 and 2 in a new situation of object permanence. Results showed that only the position changes that cats have directly perceived are encoded and activated in working memory, because they are unable to represent or infer invisible movements.

  9. Permanent pacemaker implantation in octogenarians with unexplained syncope and positive electrophysiologic testing.

    Science.gov (United States)

    Giannopoulos, Georgios; Kossyvakis, Charalampos; Panagopoulou, Vasiliki; Tsiachris, Dimitrios; Doudoumis, Konstantinos; Mavri, Maria; Vrachatis, Dimitrios; Letsas, Konstantinos; Efremidis, Michael; Katsivas, Apostolos; Lekakis, John; Deftereos, Spyridon

    2017-05-01

    Syncope is a common problem in the elderly, and a permanent pacemaker is a therapeutic option when a bradycardic etiology is revealed. However, the benefit of pacing when no association of symptoms to bradycardia has been shown is not clear, especially in the elderly. The aim of this study was to evaluate the effect of pacing on syncope-free mortality in patients aged 80 years or older with unexplained syncope and "positive" invasive electrophysiologic testing (EPT). This was an observational study. A positive EPT for the purposes of this study was defined by at least 1 of the following: a corrected sinus node recovery time of >525 ms, a basic HV interval of >55 ms, detection of infra-Hisian block, or appearance of second-degree atrioventricular block on atrial decremental pacing at a paced cycle length of >400 ms. Among the 2435 screened patients, 228 eligible patients were identified, 145 of whom were implanted with a pacemaker. Kaplan-Meier analysis determined that time to event (syncope or death) was 50.1 months (95% confidence interval 45.4-54.8 months) with a pacemaker vs 37.8 months (95% confidence interval 31.3-44.4 months) without a pacemaker (log-rank test, P = .001). The 4-year time-dependent estimate of the rate of syncope was 12% vs 44% (P pacemaker implantation was independently associated with longer syncope-free survival. Significant differences were also shown in the individual components of the primary outcome measure (syncope and death from any cause). Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  10. 78 FR 7460 - Stakeholder Meeting on the Nationally Recognized Testing Laboratory Program

    Science.gov (United States)

    2013-02-01

    ...] Stakeholder Meeting on the Nationally Recognized Testing Laboratory Program AGENCY: Occupational Safety and Health Administration (OSHA), Labor. ACTION: Notice of stakeholder meeting. SUMMARY: OSHA invites interested parties to attend an informal stakeholder meeting concerning Nationally Recognized Testing...

  11. Optimizing Tuberculosis Testing for Basic Laboratories

    Science.gov (United States)

    Ramos, Eric; Schumacher, Samuel G.; Siedner, Mark; Herrera, Beatriz; Quino, Willi; Alvarado, Jessica; Montoya, Rosario; Grandjean, Louis; Martin, Laura; Sherman, Jonathan M.; Gilman, Robert H.; Evans, Carlton A.

    2010-01-01

    Optimal tuberculosis testing usually involves sputum centrifugation followed by broth culture. However, centrifuges are biohazardous and scarce in the resource-limited settings where most tuberculosis occurs. To optimize tuberculosis testing for these settings, centrifugation of 111 decontaminated sputum samples was compared with syringe-aspiration through polycarbonate membrane-filters that were then cultured in broth. To reduce the workload of repeated microscopic screening of broth cultures for tuberculosis growth, the colorimetric redox indicator 2,3-diphenyl-5-(2-thienyl) tetrazolium chloride was added to the broth, which enabled naked-eye detection of culture positivity. This combination of filtration and colorimetric growth-detection gave similar results to sputum centrifugation followed by culture microscopy regarding mean colony counts (43 versus 48; P = 0.6), contamination rates (0.9% versus 1.8%; P = 0.3), and sensitivity (94% versus 95%; P = 0.7), suggesting equivalency of the two methods. By obviating centrifugation and repeated microscopic screening of cultures, this approach may constitute a more appropriate technology for rapid and sensitive tuberculosis diagnosis in basic laboratories. PMID:20889887

  12. Radionuclides gauges. Gauges designed for permanent installation

    International Nuclear Information System (INIS)

    1987-06-01

    This present norm determines, for radionuclides gauges designed for permanent installation, the characteristics that these gauges should satisfied in their construction and performance to respect the prescriptions. It indicates the testing methods which permit to verify the agreement, gives a classification of gauges and specifies the indications to put on the emitter block [fr

  13. Drilling induced damage of core samples. Evidences from laboratory testing and numerical modelling

    International Nuclear Information System (INIS)

    Lanaro, Flavio

    2008-01-01

    Extensive sample testing in uniaxial and Brazilian test conditions were carried out for the Shobasama and MIU Research Laboratory Site (Gifu Pref., Japan). The compressive and tensile strength of the samples was observed to be negatively correlated to the in-situ stress components. Such correlation was interpreted as stress-release induced sample damage. Similar stress conditions were then numerically simulated by means of the BEM-DDM code FRACOD 2D in plane strain conditions. This method allows for explicitly consider the influence of newly initiated or propagating fractures on the stress field and deformation of the core during drilling process. The models show that already at moderate stress levels some fracturing of the core during drilling might occur leading to reduced laboratory strength of the samples. Sample damage maps were produced independently from the laboratory test results and from the numerical models and show good agreement with each other. (author)

  14. Launching a Laboratory Testing Process Quality Improvement Toolkit: From the Shared Networks of Colorado Ambulatory Practices and Partners (SNOCAP).

    Science.gov (United States)

    Fernald, Douglas; Hamer, Mika; James, Kathy; Tutt, Brandon; West, David

    2015-01-01

    Family medicine and internal medicine physicians order diagnostic laboratory tests for nearly one-third of patient encounters in an average week, yet among medical errors in primary care, an estimated 15% to 54% are attributed to laboratory testing processes. From a practice improvement perspective, we (1) describe the need for laboratory testing process quality improvements from the perspective of primary care practices, and (2) describe the approaches and resources needed to implement laboratory testing process quality improvements in practice. We applied practice observations, process mapping, and interviews with primary care practices in the Shared Networks of Colorado Ambulatory Practices and Partners (SNOCAP)-affiliated practice-based research networks that field-tested in 2013 a laboratory testing process improvement toolkit. From the data collected in each of the 22 participating practices, common testing quality issues included, but were not limited to, 3 main testing process steps: laboratory test preparation, test tracking, and patient notification. Three overarching qualitative themes emerged: practices readily acknowledge multiple laboratory testing process problems; practices know that they need help addressing the issues; and practices face challenges with finding patient-centered solutions compatible with practice priorities and available resources. While practices were able to get started with guidance and a toolkit to improve laboratory testing processes, most did not seem able to achieve their quality improvement aims unassisted. Providing specific guidance tools with practice facilitation or other rapid-cycle quality improvement support may be an effective approach to improve common laboratory testing issues in primary care. © Copyright 2015 by the American Board of Family Medicine.

  15. Laboratory and field tests of the Sutron RLR-0003-1 water level sensor

    Science.gov (United States)

    Fulford, Janice M.; Bryars, R. Scott

    2015-01-01

    Three Sutron RLR-0003-1 water level sensors were tested in laboratory conditions to evaluate the accuracy of the sensor over the manufacturer’s specified operating temperature and distance-to-water ranges. The sensor was also tested for compliance to SDI-12 communication protocol and in field conditions at a U.S. Geological Survey (USGS) streamgaging site. Laboratory results were compared to the manufacturer’s accuracy specification for water level and to the USGS Office of Surface Water (OSW) policy requirement that water level sensors have a measurement uncertainty of no more than 0.01 foot or 0.20 percent of the indicated reading. Except for one sensor, the differences for the temperature testing were within 0.05 foot and the average measurements for the sensors were within the manufacturer’s accuracy specification. Two of the three sensors were within the manufacturer’s specified accuracy and met the USGS accuracy requirements for the laboratory distance to water testing. Three units passed a basic SDI-12 communication compliance test. Water level measurements made by the Sutron RLR-0003-1 during field testing agreed well with those made by the bubbler system and a Design Analysis Associates (DAA) H3613 radar, and they met the USGS accuracy requirements when compared to the wire-weight gage readings.

  16. Radioactive material package testing capabilities at Sandia National Laboratories

    International Nuclear Information System (INIS)

    Uncapher, W.L.; Hohnstreiter, G.F.

    1995-01-01

    Evaluation and certification of radioactive and hazardous material transport packages can be accomplished by subjecting these packages to normal transport and hypothetical accident test conditions. The regulations allow package designers to certify packages using analysis, testing, or a combination of analysis and testing. Testing can be used to substantiate assumptions used in analytical models and to demonstrate package structural and thermal response. Regulatory test conditions include impact, puncture, crush, penetration, water spray, immersion, and thermal environments. Testing facilities are used to simulate the required test conditions and provide measurement response data. Over the past four decades, comprehensive testing facilities have been developed at Sandia National Laboratories to perform a broad range of verification and certification tests on hazardous and radioactive material packages or component sections. Sandia's facilities provide an experience base that has been established during the development and certification of many package designs. These unique facilities, along with innovative instrumentation data collection capabilities and techniques, simulate a broad range of testing environments. In certain package designs, package testing can be an economical alternative to complex analysis to resolve regulatory questions or concerns

  17. Alloy design of Nd2, Fe14B permanent magnets

    International Nuclear Information System (INIS)

    Horton, J.A.; Herchenroeder, J.W.

    2000-01-01

    This report summarizes the results of research conducted as part of CRADA ORNL94-0279 between Oak Ridge National Laboratory and Magnequench International, Inc. The objective was to gain a better understanding of the fracture process in the rare earth based permanent magnets in order to possibly improve the mechanical properties of these inherently brittle intermetallics. The first part of the study established a technique for measuring a critical property, fracture toughness, and surveying currently available commercial material made by a number of different processes

  18. Economic evaluation of laboratory testing strategies for hospital-associated Clostridium difficile infection.

    Science.gov (United States)

    Schroeder, Lee F; Robilotti, Elizabeth; Peterson, Lance R; Banaei, Niaz; Dowdy, David W

    2014-02-01

    Clostridium difficile infection (CDI) is the most common cause of infectious diarrhea in health care settings, and for patients presumed to have CDI, their isolation while awaiting laboratory results is costly. Newer rapid tests for CDI may reduce this burden, but the economic consequences of different testing algorithms remain unexplored. We used decision analysis from the hospital perspective to compare multiple CDI testing algorithms for adult inpatients with suspected CDI, assuming patient management according to laboratory results. CDI testing strategies included combinations of on-demand PCR (odPCR), batch PCR, lateral-flow diagnostics, plate-reader enzyme immunoassay, and direct tissue culture cytotoxicity. In the reference scenario, algorithms incorporating rapid testing were cost-effective relative to nonrapid algorithms. For every 10,000 symptomatic adults, relative to a strategy of treating nobody, lateral-flow glutamate dehydrogenase (GDH)/odPCR generated 831 true-positive results and cost $1,600 per additional true-positive case treated. Stand-alone odPCR was more effective and more expensive, identifying 174 additional true-positive cases at $6,900 per additional case treated. All other testing strategies were dominated by (i.e., more costly and less effective than) stand-alone odPCR or odPCR preceded by lateral-flow screening. A cost-benefit analysis (including estimated costs of missed cases) favored stand-alone odPCR in most settings but favored odPCR preceded by lateral-flow testing if a missed CDI case resulted in less than $5,000 of extended hospital stay costs and 93%, or if the symptomatic carrier proportion among the toxigenic culture-positive cases was >80%. These results can aid guideline developers and laboratory directors who are considering rapid testing algorithms for diagnosing CDI.

  19. Proficiency Test Program Involvement as a Tool for External Quality Control for Radiochemistry and Environmental Laboratory, Malaysian Nuclear Agency

    International Nuclear Information System (INIS)

    Nurrul Assyikeen Mohd Jaffary; Wo, Y.M.; Zal U'yun Wan Mahmood; Norfaizal Mohamed; Abdul Kadir Ishak; Noor Fadzilah Yusof; Jalal Sharib

    2016-01-01

    As the only Laboratory in Malaysia under the IAEA Analytical Laboratories for the Measurement of Environmental Radioactivity (ALMERA) Network, the Radiochemistry and Environmental Laboratory (RAS), Malaysian Nuclear Agency participates in the proficiency test programmes organised by ALMERA to achieve mutual acceptance of analytical data. The ALMERA has been providing quality support of proficiency tests using sets of different samples matrices and radionuclide levels typically encountered in environmental and food monitoring laboratories. The involvement of RAS laboratory in the IAEA proficiency tests gives opportunity to improve the laboratory capability and personnel skills in the field of radioactivity testing. (author)

  20. Effect of accelerated ageing and surface sealing on the permanent deformation of auto-polymerising soft linings.

    Science.gov (United States)

    da Silva, Joaquim; Takahashi, Jessica; Nuňez, Juliana; Consani, Rafael; Mesquita, Marcelo

    2012-09-01

    To compare the effects of different ageing methods on the permanent deformation of two permanent soft liners. The materials selected were auto-polymerising acrylic resin and silicone-based reliners. Sealer coating was also evaluated. Sixty specimens of each reliner were manufactured (12.7 mm diameter and 19 mm length). Specimens were randomly distributed into 12 groups (n = 10) and submitted to one of the accelerated ageing processes. Permanent deformation tests were conducted with a mechanical device described within the American Dental Association specification number 18 with a compressive load of 750 gf applied for 30 s. All data were submitted for statistical analysis. Mann-Whitney test compared the effect of the surface sealer on each material and the permanent deformation of the materials in the same ageing group (p = 0.05). Kruskal-Wallis and Dunn tests compared all ageing groups of each material (p = 0.05). The silicone-based reliner presented a lower permanent deformation than the acrylic resin-based reliner, regardless of the ageing procedure. The surface sealer coating was effective only for the thermocycled silicone group and the accelerated ageing processes affected only the permanent deformation of the acrylic resin-based material. The silicone-based reliner presented superior elastic properties and the thermocycling was more effective in ageing the materials. © 2010 The Gerodontology Society and John Wiley & Sons A/S.

  1. [The external evaluation of study quality: the role in maintaining the reliability of laboratory information].

    Science.gov (United States)

    Men'shikov, V V

    2013-08-01

    The external evaluation of quality of clinical laboratory examinations was gradually introduced in USSR medical laboratories since 1970s. In Russia, in the middle of 1990 a unified all-national system of external evaluation quality was organized known as the Federal center of external evaluation of quality at the basis of laboratory of the state research center of preventive medicine. The main positions of policy in this area were neatly formulated in the guidance documents of ministry of Health. Nowadays, the center of external evaluation of quality proposes 100 and more types of control studies and permanently extends their specter starting from interests of different disciplines of clinical medicine. The consistent participation of laboratories in the cycles of external evaluation of quality intrinsically promotes improvement of indicators of properness and precision of analysis results and increases reliability of laboratory information. However, a significant percentage of laboratories does not participate at all in external evaluation of quality or takes part in control process irregularly and in limited number of tests. The managers of a number of medical organizations disregard the application of the proposed possibilities to increase reliability of laboratory information and limit financing of studies in the field of quality control. The article proposes to adopt the national standard on the basis of ISO 17043 "Evaluation of compliance. The common requirements of professional competence testing".

  2. Efficient IEC permanent-magnet motor (3 kW) - Final report; Effizienter IEC Permanent-Magnet-Motor (3 kW) - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Lindegger, M. [Circle Motor AG, Guemligen (Switzerland); Biner, H. P.; Evequoz, B. [Haute Ecole valaisanne, Sion (Switzerland); Salathe, D. [Hochschule Luzern, Technik und Architektur, Horw (Switzerland)

    2008-04-15

    Efficient permanent-magnet motors achieve in the area up to 100 kW a higher efficiency than induction machines (standard motors). A simple and fast energy saving option is the exchange of inefficient standard motors. The objective of this work is to install a 3 kW permanent-magnet motor in a standard IEC housing and the optimization of the design for high efficiency. Another objective is the development and the realization of an efficient variable speed control. The efficiency of the motor and the inverter with the control system must be demonstrated by tests. These tasks have been split between Circle Motor AG and the universities of applied sciences of Valais and Lucerne. Considering high-efficiency and low manufacturing cost, a brushless DC solution was adopted. This resulted in an optimum design of the motor and the control system realized with a three-phase rectifier, a buck converter with variable DC voltage, and a three-phase inverter feeding full positive and negative current to two of the legs simultaneously. The maximum measured efficiency is about 96.5% for the inverter and 92% for the motor. With the advantage of the variable speed operation, the efficiency of the realized 3 kW permanent magnet motor together with the control system is always higher than the efficiency of a measured class EFF1 induction motor, even with a direct connection to the grid. The permanent-magnet motor is also about 10 kg lighter. The cost calculation shows that the permanent-magnet motor can be competitive with the induction motor when speed control is desired. This is also the domain with the largest potential for energy savings from variable speed pumps, compressors, fans. (author)

  3. The Permanent Magnet Operating Mechanism of Double Coil Parallel Driven at a High Speed

    Directory of Open Access Journals (Sweden)

    WEI Xau-Lao

    2017-02-01

    Full Text Available Abstract:Operating mechanism is the main part of breaker,and the quality of breaker will directly influence the safe operation of power system. Because of the continuous improvement requirements of switch,in order to mak this actuator faster and more powerful closing,this paper proposes a double coil parallel driven permanent magnet actuator at a high speed. This paper expounds the working principle of single and double coil parallel driven permanent magnet actuator. It uses Ansoft building model and contrasts test results. In prance we designed and produced the single and double coil parallel driven permanent magnet actuator for experimental study. The simulation and experiment results show that double coil parallel driven permanent magnet actuator,compared with single coil parallel driven permanent magnet actuator,has a better and faster action performance. Thus,the double coil parallel driven permanent magnet actuator achieves a kind of optimization.

  4. Deployment of Remotely-Accessible Robotics Laboratory

    Directory of Open Access Journals (Sweden)

    Richard Balogh

    2012-03-01

    Full Text Available Robotnacka is an autonomous drawing mobile robot, designed for eaching beginners in the Logo programming language. It can also be used as an experimental platform, in our case in a remotely accessible robotic laboratory with the possibility to control the robots via the Internet. In addition to a basic version of the robot a version equipped with a gripper is available too, one with a wireless camera, and one with additional ultrasonic distance sensors. The laboratory is available on-line permanently and provides a simple way to incorporate robotics in teaching mathematics, programming and other subjects. The laboratory has been in use several years. We provide description of its functionality and summarize our experience.

  5. State of malaria diagnostic testing at clinical laboratories in the United States, 2010: a nationwide survey

    Directory of Open Access Journals (Sweden)

    Abanyie Francisca A

    2011-11-01

    Full Text Available Abstract Background The diagnosis of malaria can be difficult in non-endemic areas, such as the United States, and delays in diagnosis and errors in treatment occur too often. Methods A nationwide survey of laboratories in the United States and its nine dependent territories was conducted in 2010 to determine factors that may contribute to shortcomings in the diagnosis of malaria. This survey explored the availability of malaria diagnostic tests, techniques used, and reporting practices. Results The survey was completed by 201 participants. Ninety percent reported that their laboratories had at least one type of malaria diagnostic test available on-site. Nearly all of the respondents' laboratories performed thick and thin smears on-site; approximately 50% had access to molecular testing; and only 17% had access to rapid diagnostic tests on-site. Seventy-three percent reported fewer than five confirmed cases of malaria in their laboratory during the 12-month period preceding the survey. Twenty-eight percent stated that results of species identification took more than 24 hours to report. Only five of 149 respondents that performed testing 24 hours a day, 7 days a week complied with all of the Clinical and Laboratory Standards Institute (CLSI guidelines for analysis and reporting of results. Conclusion Although malaria diagnostic testing services were available to a majority of U.S. laboratories surveyed, very few were in complete compliance with all of the CLSI guidelines for analysis and reporting of results, and most respondents reported very few cases of malaria annually. Laboratories' difficulty in adhering to the rigorous CLSI guidelines and their personnel's lack of practice and proficiency may account for delays and errors in diagnosis. It is recommended that laboratories that infrequently process samples for malaria seek opportunities for practice and proficiency training annually and take advantage of available resources to assist in

  6. Laboratory informatics based evaluation of methylene tetrahydrofolate reductase C677T genetic test overutilization

    Directory of Open Access Journals (Sweden)

    David A Cohen

    2013-01-01

    Full Text Available Background: Laboratory data can provide a wide range of information to estimate adherence to guidelines and proper utilization of genetic testing. The methylene tetrahydrofolate reductase (MTHFR C677T variant has been demonstrated to have negligible utility in patient management. However, the testing of this variant remains pervasive. The purpose of this study was to develop methods to analyze concordance of clinician ordering practices with national guidelines. Methods: We used laboratory data to extract specific data elements including patient demographics, timestamps, physician ordering logs and temporal relationship to chemistry requests to examine 245 consecutive MTHFR tests ordered in 2011 at an academic tertiary center. A comprehensive chart review was used to identify indications for testing. These results were correlated with a retrospective analysis of 4,226 tests drawn at a range of hospitals requesting testing from a national reference laboratory over a 2-year period. MTHFR ordering practices drawn from 17 institutions were examined longitudinally from 2002 to 2011. Results: Indications for testing included cerebrovascular events (40.0% and venous thrombosis (39.1%. Family history prompted testing in eight cases. Based on acceptable hypercoagulability guidelines recommending MTHFR C677T testing only in the presence of elevated serum homocysteine, 10.6% (22/207 of adult patients met an indicated threshold at an academic tertiary center. Among 77 institutions, 14.5% (613/4226 of MTHFR testing met recommendations. Conclusion: We demonstrate an effective method to examine discreet elements of a molecular diagnostics laboratory information system at a tertiary care institution and to correlate these findings at a national level. Retrospective examination of clinicians′ request of MTHFR C677T genetic testing strongly suggests that clinicians have failed to adjust their ordering practices in light of evolving scientific and professional

  7. Permanent quadrupole magnets

    International Nuclear Information System (INIS)

    Bush, E.D. Jr.

    1976-01-01

    A family of quadrupole magnets using a soft iron return yoke and circular cross-section permanent magnet poles were fabricated to investigate the feasibility for use in ion or electron beam focusing applications in accelerators and transport lines. Magnetic field measurements yielded promising results. In fixed-field applications, permanent magnets with sufficient gradients would be a low cost substitute for conventional electromagnets, eliminating the need for power supplies, associated wiring, and cooling. (author)

  8. ISO/IEC 17025–2017 "New requirements to the competence of test and calibration laboratories"

    Directory of Open Access Journals (Sweden)

    Baranova P. O.

    2018-05-01

    Full Text Available due to the continuous improvement of the regulatory framework, there is a growing demand for laboratory centers that provide services in the field of testing. The relevance of the topic lies in the transition of laboratories to the new version of ISO/IEC 17025–2017 «General requirements for the competence of test and calibration laboratories». The article compares two versions of the standard, reveals differences and similarities. And changes in the gradation of changes are also highlighted.

  9. Testing the quality of images for permanent magnet desktop MRI systems using specially designed phantoms.

    Science.gov (United States)

    Qiu, Jianfeng; Wang, Guozhu; Min, Jiao; Wang, Xiaoyan; Wang, Pengcheng

    2013-12-21

    Our aim was to measure the performance of desktop magnetic resonance imaging (MRI) systems using specially designed phantoms, by testing imaging parameters and analysing the imaging quality. We designed multifunction phantoms with diameters of 18 and 60 mm for desktop MRI scanners in accordance with the American Association of Physicists in Medicine (AAPM) report no. 28. We scanned the phantoms with three permanent magnet 0.5 T desktop MRI systems, measured the MRI image parameters, and analysed imaging quality by comparing the data with the AAPM criteria and Chinese national standards. Image parameters included: resonance frequency, high contrast spatial resolution, low contrast object detectability, slice thickness, geometrical distortion, signal-to-noise ratio (SNR), and image uniformity. The image parameters of three desktop MRI machines could be measured using our specially designed phantoms, and most parameters were in line with MRI quality control criterion, including: resonance frequency, high contrast spatial resolution, low contrast object detectability, slice thickness, geometrical distortion, image uniformity and slice position accuracy. However, SNR was significantly lower than in some references. The imaging test and quality control are necessary for desktop MRI systems, and should be performed with the applicable phantom and corresponding standards.

  10. Testing the quality of images for permanent magnet desktop MRI systems using specially designed phantoms

    International Nuclear Information System (INIS)

    Qiu, Jianfeng; Wang, Guozhu; Min, Jiao; Wang, Xiaoyan; Wang, Pengcheng

    2013-01-01

    Our aim was to measure the performance of desktop magnetic resonance imaging (MRI) systems using specially designed phantoms, by testing imaging parameters and analysing the imaging quality. We designed multifunction phantoms with diameters of 18 and 60 mm for desktop MRI scanners in accordance with the American Association of Physicists in Medicine (AAPM) report no. 28. We scanned the phantoms with three permanent magnet 0.5 T desktop MRI systems, measured the MRI image parameters, and analysed imaging quality by comparing the data with the AAPM criteria and Chinese national standards. Image parameters included: resonance frequency, high contrast spatial resolution, low contrast object detectability, slice thickness, geometrical distortion, signal-to-noise ratio (SNR), and image uniformity. The image parameters of three desktop MRI machines could be measured using our specially designed phantoms, and most parameters were in line with MRI quality control criterion, including: resonance frequency, high contrast spatial resolution, low contrast object detectability, slice thickness, geometrical distortion, image uniformity and slice position accuracy. However, SNR was significantly lower than in some references. The imaging test and quality control are necessary for desktop MRI systems, and should be performed with the applicable phantom and corresponding standards. (paper)

  11. Artificial Neural Network Approach in Laboratory Test Reporting:  Learning Algorithms.

    Science.gov (United States)

    Demirci, Ferhat; Akan, Pinar; Kume, Tuncay; Sisman, Ali Riza; Erbayraktar, Zubeyde; Sevinc, Suleyman

    2016-08-01

    In the field of laboratory medicine, minimizing errors and establishing standardization is only possible by predefined processes. The aim of this study was to build an experimental decision algorithm model open to improvement that would efficiently and rapidly evaluate the results of biochemical tests with critical values by evaluating multiple factors concurrently. The experimental model was built by Weka software (Weka, Waikato, New Zealand) based on the artificial neural network method. Data were received from Dokuz Eylül University Central Laboratory. "Training sets" were developed for our experimental model to teach the evaluation criteria. After training the system, "test sets" developed for different conditions were used to statistically assess the validity of the model. After developing the decision algorithm with three iterations of training, no result was verified that was refused by the laboratory specialist. The sensitivity of the model was 91% and specificity was 100%. The estimated κ score was 0.950. This is the first study based on an artificial neural network to build an experimental assessment and decision algorithm model. By integrating our trained algorithm model into a laboratory information system, it may be possible to reduce employees' workload without compromising patient safety. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  12. The Computerized Laboratory Notebook concept for genetic toxicology experimentation and testing.

    Science.gov (United States)

    Strauss, G H; Stanford, W L; Berkowitz, S J

    1989-03-01

    We describe a microcomputer system utilizing the Computerized Laboratory Notebook (CLN) concept developed in our laboratory for the purpose of automating the Battery of Leukocyte Tests (BLT). The BLT was designed to evaluate blood specimens for toxic, immunotoxic, and genotoxic effects after in vivo exposure to putative mutagens. A system was developed with the advantages of low cost, limited spatial requirements, ease of use for personnel inexperienced with computers, and applicability to specific testing yet flexibility for experimentation. This system eliminates cumbersome record keeping and repetitive analysis inherent in genetic toxicology bioassays. Statistical analysis of the vast quantity of data produced by the BLT would not be feasible without a central database. Our central database is maintained by an integrated package which we have adapted to develop the CLN. The clonal assay of lymphocyte mutagenesis (CALM) section of the CLN is demonstrated. PC-Slaves expand the microcomputer to multiple workstations so that our computerized notebook can be used next to a hood while other work is done in an office and instrument room simultaneously. Communication with peripheral instruments is an indispensable part of many laboratory operations, and we present a representative program, written to acquire and analyze CALM data, for communicating with both a liquid scintillation counter and an ELISA plate reader. In conclusion we discuss how our computer system could easily be adapted to the needs of other laboratories.

  13. 21 CFR 312.160 - Drugs for investigational use in laboratory research animals or in vitro tests.

    Science.gov (United States)

    2010-04-01

    ... research animals or in vitro tests. 312.160 Section 312.160 Food and Drugs FOOD AND DRUG ADMINISTRATION... Drugs for Investigational Use in Laboratory Research Animals or In Vitro Tests § 312.160 Drugs for investigational use in laboratory research animals or in vitro tests. (a) Authorization to ship. (1)(i) A person...

  14. Laboratory tests of overpressure differential systems for smoke protection of lobbies

    Science.gov (United States)

    Szałański, Paweł; Misiński, Jacek

    2017-11-01

    Paper presents the methodology of laboratory tests for ventilation overpressure differential systems for smoke protection of lobbies. Research area consists of two spaces representing the lobby and the area under fire equipped with proper ventilation installation. This allows testing of overpressure differential systems for smoke protection of lobbies. Moreover, piece of laboratory tests results for two selected smoke protection systems for lobbies are presented. First one is standard system with constantly opened transfer-damper mounted between lobby and area under fire. Second one - system with so called "electronic transfer" based on two dampers (supplying air to a lobby and to unprotected area alternatively). Opening and closing both dampers is electronically controlled. Changes of pressure difference between lobby and fire affected area during closing and opening doors between those spaces is presented. Conclusions, concerning the possibility of meeting the time period criteria of pressure difference stabilization required by standards, are presented and discussed for both systems.

  15. 77 FR 39501 - Current List of Laboratories and Instrumented Initial Testing Facilities Which Meet Minimum...

    Science.gov (United States)

    2012-07-03

    ...-202-2783, (Formerly: Forensic Toxicology Laboratory Baptist Medical Center) Clinical Reference Lab... Minneapolis Veterans Affairs Medical Center, Forensic Toxicology Laboratory, 1 Veterans Drive, Minneapolis, MN... 65203, 573-882-1273 U.S. Army Forensic Toxicology Drug Testing Laboratory, 2490 Wilson St., Fort George...

  16. Biomagnification of hexachlorobenzene: influence of uptake routes in a laboratory test

    International Nuclear Information System (INIS)

    Egeler, P.; Meller, M.; Roembke, J.; Spoerlein, P.

    2001-01-01

    In order to evaluate such a potential biomagnification, a laboratory test was developed. It consisted of a two-step food chain including the sediment dwelling freshwater oligochaete Tubifex tubifex (Mueller) and the three-spined stickleback (Gasterosteus aculeatus, Linne), a small teleost fish which often feeds primarily on benthic invertebrates. Artificial sediment and reconstituted water were used. To examine the influence of benthic prey on the bioaccumulation of a POP in the predator, fish were exposed to 14 C-labelled hexachlorobenzene via spiked water, spiked sediment, pre-contaminated prey organisms, and to combinations of these exposure routes. Summarising the results of these experiments, it could be shown that the exposure to HCB via different routes resulted in a significantly higher accumulation in fish than an exposure to single pathways. It was concluded that the major uptake routes for fish were the overlying water and the food, whereas the contribution of spiked sediment itself was relatively small. HCB was biomagnified in the tested laboratory food chain. Therefore, concerning secondary poisoning, the environmental risk assessment of POPs like HCB should not be based on existing bioaccumulation tests alone, since they focus only on exposure via the water pathway. Instead, the influence of food and sediment as exposure routes should be considered as well, using comprehensive food chain modelling and/or laboratory studies. (orig.) [de

  17. Use of the laboratory tests of soil modulus in modelling pile behaviour

    Science.gov (United States)

    Dyka, Ireneusz

    2012-10-01

    This article deals with the question of theoretical description of behaviour of a single pile rested in a layered soil medium. Particular attention is paid to soil modulus which is used in calculation method for pile load-settlement curve. A brief analysis of the results obtained by laboratory tests to assess soil modulus and its nonlinear variability has been presented. The results of tests have been used in triaxial apparatus and resonant column/torsional shear device. There have also been presented the results of load-settlement calculation for a single pile under axial load with implementation of different models of soil modulus degradation. On this basis, possibilities of using particular kinds of laboratory tests in calculation procedure of foundation settlement have been presented as well as further developments of them.

  18. HVPTF-The high voltage laboratory for the ITER Neutral Beam test facility

    Energy Technology Data Exchange (ETDEWEB)

    De Lorenzi, A., E-mail: antonio.delorenzi@igi.cnr.it [Consorzio RFX-Associazione EURATOM-ENEA per la Fusione Corso Stati Uniti 4, 35127 Padova (Italy); Pilan, N.; Lotto, L.; Fincato, M. [Consorzio RFX-Associazione EURATOM-ENEA per la Fusione Corso Stati Uniti 4, 35127 Padova (Italy); Pesavento, G.; Gobbo, R. [DIE, Universita di Padova, Via Gradenigo 6A, I-35100 Padova (Italy)

    2011-10-15

    In the MITICA research program for the construction of the ITER Neutral Beam Injector prototype, a Laboratory for the investigation on high voltage holding in vacuum has been set up. This Laboratory - HVPTF: High Voltage Padova Test Facility - is presently capable of experiments up to 300 kV dc, and planned for the upgrade to 800 kV. The specific mission for this ancillary lab is the support to the electrostatic design and construction of the MITICA accelerator and the development and testing of HV components to be installed inside the MITICA accelerator during its operation. The paper describes the structure of the lab, characterized by a high degree of automation and reports the results of the commissioning at 300 kV and the first results of voltage holding between test electrodes.

  19. HVPTF-The high voltage laboratory for the ITER Neutral Beam test facility

    International Nuclear Information System (INIS)

    De Lorenzi, A.; Pilan, N.; Lotto, L.; Fincato, M.; Pesavento, G.; Gobbo, R.

    2011-01-01

    In the MITICA research program for the construction of the ITER Neutral Beam Injector prototype, a Laboratory for the investigation on high voltage holding in vacuum has been set up. This Laboratory - HVPTF: High Voltage Padova Test Facility - is presently capable of experiments up to 300 kV dc, and planned for the upgrade to 800 kV. The specific mission for this ancillary lab is the support to the electrostatic design and construction of the MITICA accelerator and the development and testing of HV components to be installed inside the MITICA accelerator during its operation. The paper describes the structure of the lab, characterized by a high degree of automation and reports the results of the commissioning at 300 kV and the first results of voltage holding between test electrodes.

  20. Choosing the right laboratory: a review of clinical and forensic toxicology services for urine drug testing in pain management.

    Science.gov (United States)

    Reisfield, Gary M; Goldberger, Bruce A; Bertholf, Roger L

    2015-01-01

    Urine drug testing (UDT) services are provided by a variety of clinical, forensic, and reference/specialty laboratories. These UDT services differ based on the principal activity of the laboratory. Clinical laboratories provide testing primarily focused on medical care (eg, emergency care, inpatients, and outpatient clinics), whereas forensic laboratories perform toxicology tests related to postmortem and criminal investigations, and drug-free workplace programs. Some laboratories now provide UDT specifically designed for monitoring patients on chronic opioid therapy. Accreditation programs for clinical laboratories have existed for nearly half a century, and a federal certification program for drug-testing laboratories was established in the 1980s. Standards of practice for forensic toxicology services other than workplace drug testing have been established in recent years. However, no accreditation program currently exists for UDT in pain management, and this review considers several aspects of laboratory accreditation and certification relevant to toxicology services, with the intention to provide guidance to clinicians in their selection of the appropriate laboratory for UDT surveillance of their patients on opioid therapy.

  1. The Validation of NAA Method Used as Test Method in Serpong NAA Laboratory

    International Nuclear Information System (INIS)

    Rina-Mulyaningsih, Th.

    2004-01-01

    The Validation Of NAA Method Used As Test Method In Serpong NAA Laboratory. NAA Method is a non standard testing method. The testing laboratory shall validate its using method to ensure and confirm that it is suitable with application. The validation of NAA methods have been done with the parameters of accuracy, precision, repeatability and selectivity. The NIST 1573a Tomato Leaves, NIES 10C Rice flour unpolished and standard elements were used in this testing program. The result of testing with NIST 1573a showed that the elements of Na, Zn, Al and Mn are met from acceptance criteria of accuracy and precision, whereas Co is rejected. The result of testing with NIES 10C showed that Na and Zn elements are met from acceptance criteria of accuracy and precision, but Mn element is rejected. The result of selectivity test showed that the value of quantity is between 0.1-2.5 μg, depend on the elements. (author)

  2. Portuguese Family Physicians' Awareness of Diagnostic and Laboratory Test Costs: A Cross-Sectional Study.

    Directory of Open Access Journals (Sweden)

    Luísa Sá

    Full Text Available Physicians' ability to make cost-effective decisions has been shown to be affected by their knowledge of health care costs. This study assessed whether Portuguese family physicians are aware of the costs of the most frequently prescribed diagnostic and laboratory tests.A cross-sectional study was conducted in a representative sample of Portuguese family physicians, using computer-assisted telephone interviews for data collection. A Likert scale was used to assess physician's level of agreement with four statements about health care costs. Family physicians were also asked to estimate the costs of diagnostic and laboratory tests. Each physician's cost estimate was compared with the true cost and the absolute error was calculated.One-quarter (24%; 95% confidence interval: 23%-25% of all cost estimates were accurate to within 25% of the true cost, with 55% (95% IC: 53-56 overestimating and 21% (95% IC: 20-22 underestimating the true actual cost. The majority (76% of family physicians thought they did not have or were uncertain as to whether they had adequate knowledge of diagnostic and laboratory test costs, and only 7% reported receiving adequate education. The majority of the family physicians (82% said that they had adequate access to information about the diagnostic and laboratory test costs. Thirty-three percent thought that costs did not influence their decision to order tests, while 27% were uncertain.Portuguese family physicians have limited awareness of diagnostic and laboratory test costs, and our results demonstrate a need for improved education in this area. Further research should focus on identifying whether interventions in cost knowledge actually change ordering behavior, in identifying optimal methods to disseminate cost information, and on improving the cost-effectiveness of care.

  3. Portuguese Family Physicians’ Awareness of Diagnostic and Laboratory Test Costs: A Cross-Sectional Study

    Science.gov (United States)

    Sá, Luísa; Costa-Santos, Cristina; Teixeira, Andreia; Couto, Luciana; Costa-Pereira, Altamiro; Hespanhol, Alberto; Santos, Paulo; Martins, Carlos

    2015-01-01

    Background Physicians’ ability to make cost-effective decisions has been shown to be affected by their knowledge of health care costs. This study assessed whether Portuguese family physicians are aware of the costs of the most frequently prescribed diagnostic and laboratory tests. Methods A cross-sectional study was conducted in a representative sample of Portuguese family physicians, using computer-assisted telephone interviews for data collection. A Likert scale was used to assess physician’s level of agreement with four statements about health care costs. Family physicians were also asked to estimate the costs of diagnostic and laboratory tests. Each physician’s cost estimate was compared with the true cost and the absolute error was calculated. Results One-quarter (24%; 95% confidence interval: 23%–25%) of all cost estimates were accurate to within 25% of the true cost, with 55% (95% IC: 53–56) overestimating and 21% (95% IC: 20–22) underestimating the true actual cost. The majority (76%) of family physicians thought they did not have or were uncertain as to whether they had adequate knowledge of diagnostic and laboratory test costs, and only 7% reported receiving adequate education. The majority of the family physicians (82%) said that they had adequate access to information about the diagnostic and laboratory test costs. Thirty-three percent thought that costs did not influence their decision to order tests, while 27% were uncertain. Conclusions Portuguese family physicians have limited awareness of diagnostic and laboratory test costs, and our results demonstrate a need for improved education in this area. Further research should focus on identifying whether interventions in cost knowledge actually change ordering behavior, in identifying optimal methods to disseminate cost information, and on improving the cost-effectiveness of care. PMID:26356625

  4. Open-source Software for Demand Forecasting of Clinical Laboratory Test Volumes Using Time-series Analysis.

    Science.gov (United States)

    Mohammed, Emad A; Naugler, Christopher

    2017-01-01

    Demand forecasting is the area of predictive analytics devoted to predicting future volumes of services or consumables. Fair understanding and estimation of how demand will vary facilitates the optimal utilization of resources. In a medical laboratory, accurate forecasting of future demand, that is, test volumes, can increase efficiency and facilitate long-term laboratory planning. Importantly, in an era of utilization management initiatives, accurately predicted volumes compared to the realized test volumes can form a precise way to evaluate utilization management initiatives. Laboratory test volumes are often highly amenable to forecasting by time-series models; however, the statistical software needed to do this is generally either expensive or highly technical. In this paper, we describe an open-source web-based software tool for time-series forecasting and explain how to use it as a demand forecasting tool in clinical laboratories to estimate test volumes. This tool has three different models, that is, Holt-Winters multiplicative, Holt-Winters additive, and simple linear regression. Moreover, these models are ranked and the best one is highlighted. This tool will allow anyone with historic test volume data to model future demand.

  5. Open-source software for demand forecasting of clinical laboratory test volumes using time-series analysis

    Directory of Open Access Journals (Sweden)

    Emad A Mohammed

    2017-01-01

    Full Text Available Background: Demand forecasting is the area of predictive analytics devoted to predicting future volumes of services or consumables. Fair understanding and estimation of how demand will vary facilitates the optimal utilization of resources. In a medical laboratory, accurate forecasting of future demand, that is, test volumes, can increase efficiency and facilitate long-term laboratory planning. Importantly, in an era of utilization management initiatives, accurately predicted volumes compared to the realized test volumes can form a precise way to evaluate utilization management initiatives. Laboratory test volumes are often highly amenable to forecasting by time-series models; however, the statistical software needed to do this is generally either expensive or highly technical. Method: In this paper, we describe an open-source web-based software tool for time-series forecasting and explain how to use it as a demand forecasting tool in clinical laboratories to estimate test volumes. Results: This tool has three different models, that is, Holt-Winters multiplicative, Holt-Winters additive, and simple linear regression. Moreover, these models are ranked and the best one is highlighted. Conclusion: This tool will allow anyone with historic test volume data to model future demand.

  6. Black holes a laboratory for testing strong gravity

    CERN Document Server

    Bambi, Cosimo

    2017-01-01

    This textbook introduces the current astrophysical observations of black holes, and discusses the leading techniques to study the strong gravity region around these objects with electromagnetic radiation. More importantly, it provides the basic tools for writing an astrophysical code and testing the Kerr paradigm. Astrophysical black holes are an ideal laboratory for testing strong gravity. According to general relativity, the spacetime geometry around these objects should be well described by the Kerr solution. The electromagnetic radiation emitted by the gas in the inner part of the accretion disk can probe the metric of the strong gravity region and test the Kerr black hole hypothesis. With exercises and examples in each chapter, as well as calculations and analytical details in the appendix, the book is especially useful to the beginners or graduate students who are familiar with general relativity while they do not have any background in astronomy or astrophysics.

  7. Economic Evaluation of Laboratory Testing Strategies for Hospital-Associated Clostridium difficile Infection

    Science.gov (United States)

    Robilotti, Elizabeth; Peterson, Lance R.; Banaei, Niaz; Dowdy, David W.

    2014-01-01

    Clostridium difficile infection (CDI) is the most common cause of infectious diarrhea in health care settings, and for patients presumed to have CDI, their isolation while awaiting laboratory results is costly. Newer rapid tests for CDI may reduce this burden, but the economic consequences of different testing algorithms remain unexplored. We used decision analysis from the hospital perspective to compare multiple CDI testing algorithms for adult inpatients with suspected CDI, assuming patient management according to laboratory results. CDI testing strategies included combinations of on-demand PCR (odPCR), batch PCR, lateral-flow diagnostics, plate-reader enzyme immunoassay, and direct tissue culture cytotoxicity. In the reference scenario, algorithms incorporating rapid testing were cost-effective relative to nonrapid algorithms. For every 10,000 symptomatic adults, relative to a strategy of treating nobody, lateral-flow glutamate dehydrogenase (GDH)/odPCR generated 831 true-positive results and cost $1,600 per additional true-positive case treated. Stand-alone odPCR was more effective and more expensive, identifying 174 additional true-positive cases at $6,900 per additional case treated. All other testing strategies were dominated by (i.e., more costly and less effective than) stand-alone odPCR or odPCR preceded by lateral-flow screening. A cost-benefit analysis (including estimated costs of missed cases) favored stand-alone odPCR in most settings but favored odPCR preceded by lateral-flow testing if a missed CDI case resulted in less than $5,000 of extended hospital stay costs and 93%, or if the symptomatic carrier proportion among the toxigenic culture-positive cases was >80%. These results can aid guideline developers and laboratory directors who are considering rapid testing algorithms for diagnosing CDI. PMID:24478478

  8. Performance specifications for the extra-analytical phases of laboratory testing: Why and how.

    Science.gov (United States)

    Plebani, Mario

    2017-07-01

    An important priority in the current healthcare scenario should be to address errors in laboratory testing, which account for a significant proportion of diagnostic errors. Efforts made in laboratory medicine to enhance the diagnostic process have been directed toward improving technology, greater volumes and more accurate laboratory tests being achieved, but data collected in the last few years highlight the need to re-evaluate the total testing process (TTP) as the unique framework for improving quality and patient safety. Valuable quality indicators (QIs) and extra-analytical performance specifications are required for guidance in improving all TTP steps. Yet in literature no data are available on extra-analytical performance specifications based on outcomes, and nor is it possible to set any specification using calculations involving biological variability. The collection of data representing the state-of-the-art based on quality indicators is, therefore, underway. The adoption of a harmonized set of QIs, a common data collection and standardised reporting method is mandatory as it will not only allow the accreditation of clinical laboratories according to the International Standard, but also assure guidance for promoting improvement processes and guaranteeing quality care to patients. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  9. Development of 2.45GHz compact ECR ion sources with permanent magnets

    International Nuclear Information System (INIS)

    Tojyo, E.; Ohshiro, Y.; Oyaizu, M.; Shirakabe, Y.

    1993-05-01

    Two kinds of new compact ECR ion sources have been developed by use of permanent magnets only, for the purpose of acceleration tests of the 25.5MHz INS split coaxial RFQ linac and the 50MHz one. Confined magnetic fields of sources are constructed by permanent magnets only. In this paper design parameters, structures, magnetic field distributions and extracted beam properties of these sources are described briefly. (author)

  10. Cryogenic Permanent Magnet Undulators

    International Nuclear Information System (INIS)

    Chavanne, J.; Lebec, G.; Penel, C.; Revol, F.; Kitegi, C.

    2010-01-01

    For an in-vacuum undulator operated at small gaps the permanent magnet material needs to be highly resistant to possible electron beam exposure. At room temperature, one generally uses Sm 2 Co 17 or high coercivity NdFeB magnets at the expense of a limited field performance. In a cryogenic permanent magnet undulator (CPMU), at a temperature of around 150 K, any NdFeB grade reveals a coercivity large enough to be radiation resistant. In particular, very high remanence NdFeB material can be used to build undulators with enhanced field and X-ray brilliance at high photon energy provided that the pre-baking of the undulator above 100 deg. C can be eliminated. The ESRF has developed a full scale 2 m long CPMU with a period of 18 mm. This prototype has been in operation on the ID6 test beamline since January 2008. A significant effort was put into the characterization of NdFeB material at low temperature, the development of dedicated magnetic measurement systems and cooling methods. The measured heat budget with beam is found to be larger than expected without compromising the smooth operation of the device. Leading on from this first experience, new CPMUs are currently being considered for the upgrade of the ESRF.

  11. Mounted Smartphones as Measurement and Control Platforms for Motor-Based Laboratory Test-Beds †

    Science.gov (United States)

    Frank, Jared A.; Brill, Anthony; Kapila, Vikram

    2016-01-01

    Laboratory education in science and engineering often entails the use of test-beds equipped with costly peripherals for sensing, acquisition, storage, processing, and control of physical behavior. However, costly peripherals are no longer necessary to obtain precise measurements and achieve stable feedback control of test-beds. With smartphones performing diverse sensing and processing tasks, this study examines the feasibility of mounting smartphones directly to test-beds to exploit their embedded hardware and software in the measurement and control of the test-beds. This approach is a first step towards replacing laboratory-grade peripherals with more compact and affordable smartphone-based platforms, whose interactive user interfaces can engender wider participation and engagement from learners. Demonstrative cases are presented in which the sensing, computation, control, and user interaction with three motor-based test-beds are handled by a mounted smartphone. Results of experiments and simulations are used to validate the feasibility of mounted smartphones as measurement and feedback control platforms for motor-based laboratory test-beds, report the measurement precision and closed-loop performance achieved with such platforms, and address challenges in the development of platforms to maintain system stability. PMID:27556464

  12. Testing laboratories, its function in ensuring industrial safety

    International Nuclear Information System (INIS)

    Sanchez Fernandez, M.

    2015-01-01

    This article discusses and justifies the development of industrial laboratories (testing and calibration) in Spain, since its embryo, its creation and development, to the present day. Likewise, presents its interrelation with other agents, as well as the legislative and technical framework is application along to the years. Within this development of the sector, highlights the period of the conformity assessment, and consequently its relationship with Industrial safety. Finally, describes the organizational situation of the sector both nationally and internationally. (Author)

  13. Advanced laboratory for testing plasma thrusters and Hall thruster measurement campaign

    Directory of Open Access Journals (Sweden)

    Szelecka Agnieszka

    2016-06-01

    Full Text Available Plasma engines are used for space propulsion as an alternative to chemical thrusters. Due to the high exhaust velocity of the propellant, they are more efficient for long-distance interplanetary space missions than their conventional counterparts. An advanced laboratory of plasma space propulsion (PlaNS at the Institute of Plasma Physics and Laser Microfusion (IPPLM specializes in designing and testing various electric propulsion devices. Inside of a special vacuum chamber with three performance pumps, an environment similar to the one that prevails in space is created. An innovative Micro Pulsed Plasma Thruster (LμPPT with liquid propellant was built at the laboratory. Now it is used to test the second prototype of Hall effect thruster (HET operating on krypton propellant. Meantime, an improved prototype of krypton Hall thruster is constructed.

  14. Eruption age of permanent mandibular first molars and central incisors in the south Indian population

    Directory of Open Access Journals (Sweden)

    Gupta Rakhi

    2007-01-01

    Full Text Available Objective: The existing eruption schedules for permanent and deciduous dentition are based on studies in the Western population. Since Indians differ from Westerners racially, genetically, and environmentally, these studies fail to provide relevant guidance on the eruption schedule in the Indian population. This study aims at determining the eruption pattern of permanent mandibular molars and central incisors in the south Indian population. Materials and Methods: 10,156 apparently healthy Indian children in the age-group of 6-9 years were examined with mouth mirror and probe under adequate illumination for the status of the eruption of the permanent mandibular first molar and permanent mandibular central incisor. Pearson′s Chi-square test with Yates′ continuity correction was used to calculate the P -value for comparison of proportion between girls and boys. The values obtained in our study were compared with the standard values. The Z-test with continuity correction was used to calculate the P -value. Results: As per our study, the permanent mandibular first molars and central incisors erupted one to two years later compared to the values reported in Westerners. The earlier eruption of the permanent mandibular first molars compared to the permanent mandibular central incisors, as well as the earlier eruption of both the teeth in girls compared to boys, were in accordance with the existing literature. Conclusion: The eruption age reported by us may form a standard reference for eruption age in Indians.

  15. Permanent disposal by burial of highly radioactive wastes incorporated into glass

    International Nuclear Information System (INIS)

    Merritt, W.F.

    1967-01-01

    A method has been developed at Chalk River for incorporating high-level fission product wastes from nuclear fuel processing into glass blocks for ultimate disposal. Nitric acid solutions of fission products were mixed with nepheline-syenite and lime in crucibles and fired in a kiln to a temperature of 1350 o C to form a glass with high resistance to leaching. Two test disposals of glass blocks were made into the ground below the water table. The first, in August 1958, contained about 300 Ci in 25 blocks of a highly resistant glass. The second, in May 1960, contained about 1100 Ci in 25 blocks of a less resistant formulation. Monitoring of the two tests has continued for eight and six years respectively. A soil sampling programme has indicated that the leaching rate tended to decrease with time and is now less than 10 -10 g/cm 2 per day, or two orders of magnitude lower than that predicted from laboratory leaching tests. These results indicate that the method is suitable for permanent disposal of high-level nuclear wastes and that the blocks could be buried unprotected in a controlled area, even in saturated sand of low exchange capacity. Burial above the saturated zone in an and region would result in even less release of radioactivity from the glass. (author)

  16. Laboratory testing and economic analysis of high RAP warm mixed asphalt.

    Science.gov (United States)

    2009-03-24

    This report contains laboratory testing, economic analysis, literature review, and information obtained from multiple producers throughout the state of Mississippi regarding the use of high RAP (50 % to 100%) mixtures containing warm mix additives. T...

  17. Summary of microsatellite instability test results from laboratories participating in proficiency surveys: proficiency survey results from 2005 to 2012.

    Science.gov (United States)

    Boyle, Theresa A; Bridge, Julia A; Sabatini, Linda M; Nowak, Jan A; Vasalos, Patricia; Jennings, Lawrence J; Halling, Kevin C

    2014-03-01

    The College of American Pathologists surveys are the largest laboratory peer comparison programs in the world. These programs allow laboratories to regularly evaluate their performance and improve the accuracy of the patient test results they provide. Proficiency testing is offered twice a year to laboratories performing microsatellite instability testing. These surveys are designed to emulate clinical practice, and some surveys have more challenging cases to encourage the refinement of laboratory practices. This report summarizes the results and trends in microsatellite instability proficiency testing from participating laboratories from the inception of the program in 2005 through 2012. We compiled and analyzed data for 16 surveys of microsatellite instability proficiency testing during 2005 to 2012. The number of laboratories participating in the microsatellite instability survey has more than doubled from 42 to 104 during the 8 years analyzed. An average of 95.4% of the laboratories correctly classified each of the survey test samples from the 2005A through 2012B proficiency challenges. In the 2011B survey, a lower percentage of laboratories (78.4%) correctly classified the specimen, possibly because of overlooking subtle changes of microsatellite instability and/or failing to enrich the tumor content of the specimen to meet the limit of detection of their assay. In general, laboratories performed well in microsatellite instability testing. This testing will continue to be important in screening patients with colorectal and other cancers for Lynch syndrome and guiding the management of patients with sporadic colorectal cancer.

  18. Wind turbine integrated multipole permanent magnet generator (PMG)

    Energy Technology Data Exchange (ETDEWEB)

    Vilsboell, N.; Pinegin, A.; Goussarov, D.

    1996-01-01

    Designed permanent magnet generator (PMG - 20 kW) possesses a number of advantages: it makes possible to replace gearbox, the generator and possibly the hub of the wind turbine by combining wind rotor with external rotor of the generator; use of rare earth magnets Nd-Fe-B allows to reduce mass and dimensions of the generator; use of the PMG for wind turbines increases the reliability of the construction during the life time, comparing to the conventional design (gearbox, asynchronous generator). The test of the PMG -20 kW informs that design method, developed for calculation of multipole permanent magnet generators is correct in general and meets engineering requirements. The calculation uncertainty of the magnetic system and output characteristics does not exceed 2-3%. The test shows, that the maximum efficiency of the PGM - 20 kW with full load can be achieved as high as 90-91.5% and excels the efficiency of the traditional system `generator-gearbox` by 4-5.5%. Designing permanent magnet generator, it is recommended to take into account voltage stabilization (capacitance). Efficiency is expected to be higher, mass and production cost of the generator can be reduced by 25-30%. The frequency converter shall be used not only for control of rotational speed, but also to obtain sinusoidal capacitive current on the generator side. For PMG - 20 kW the angle between voltage and current should be within the range 0-23%. (au)

  19. Effects of the pyrethroid insecticide gamma-cyhalothrin on aquatic invertebrates in laboratory and outdoor microcosm tests

    NARCIS (Netherlands)

    Wijngaarden, van R.P.A.; Barber, I.; Brock, T.C.M.

    2009-01-01

    The sensitivity of a range of freshwater lentic invertebrates to gamma-cyhalothrin (GCH), a single enantiomer of the synthetic pyrethroid lambda-cyhalothrin, was assessed in single species laboratory tests and an outdoor multi-species ecosystem test. The most sensitive species in the laboratory

  20. Idaho National Engineering Laboratory, Test Area North, Hangar 629 -- Photographs, written historical and descriptive data

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    The report describes the history of the Idaho National Engineering Laboratory`s Hangar 629. The hangar was built to test the possibility of linking jet engine technology with nuclear power. The history of the project is described along with the development and eventual abandonment of the Flight Engine Test hangar. The report contains historical photographs and architectural drawings.

  1. Bridging naturalistic and laboratory assessment of memory: the Baycrest mask fit test.

    Science.gov (United States)

    Armson, Michael J; Abdi, Hervé; Levine, Brian

    2017-09-01

    Autobiographical memory tests provide a naturalistic counterpoint to the artificiality of laboratory research methods, yet autobiographical events are uncontrolled and, in most cases, unverifiable. In this study, we capitalised on a scripted, complex naturalistic event - the mask fit test (MFT), a standardised procedure required of hospital employees - to bridge the gap between naturalistic and laboratory memory assessment. We created a test of recognition memory for the MFT and administered it to 135 hospital employees who had undertaken the MFT at various points over the past five years. Multivariate analysis revealed two dimensions defined by accuracy and response bias. Accuracy scores showed the expected relationship to encoding-test delay, supporting the validity of this measure. Relative to younger adults, older adults' memory for this naturalistic event was better than would be predicted from the cognitive ageing literature, a result consistent with the notion that older adults' memory performance is enhanced when stimuli are naturalistic and personally relevant. These results demonstrate that testing recognition memory for a scripted event is a viable method of studying autobiographical memory.

  2. Creating Best Practices for the Submission of Actionable Food and Feed Testing Data Generated in State and Local Laboratories.

    Science.gov (United States)

    Wangsness, Kathryn; Salfinger, Yvonne; Randolph, Robyn; Shea, Shari; Larson, Kirsten

    2017-07-01

    Laboratory accreditation provides a level of standardization in laboratories and confidence in generated food and feed testing results. For some laboratories, ISO/IEC 17025:2005 accreditation may not be fiscally viable, or a requested test method may be out of the scope of the laboratory's accreditation. To assist laboratories for whom accreditation is not feasible, the Association of Public Health Laboratories Data Acceptance Work Group developed a white paper entitled "Best Practices for Submission of Actionable Food and Feed Testing Data Generated in State and Local Laboratories." The basic elements of a quality management system, along with other best practices that state and local food and feed testing laboratories should follow, are included in the white paper. It also covers program-specific requirements that may need to be addressed. Communication with programs and end data users is regarded as essential for establishing the reliability and accuracy of laboratory data. Following these suggested best practices can facilitate the acceptance of laboratory data, which can result in swift regulatory action and the quick removal of contaminated product from the food supply, improving public health nationally.

  3. 31 CFR 515.335 - Permanent resident alien.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Permanent resident alien. 515.335... Definitions § 515.335 Permanent resident alien. As used in § 515.208, the term permanent resident alien means an alien lawfully admitted for permanent residence into the United States. [61 FR 37386, July 18...

  4. Autistic children and the object permanence task.

    Science.gov (United States)

    Adrien, J L; Tanguay, P; Barthélémy, C; Martineaú, J; Perrot, A; Hameury, L; Sauvage, D

    1993-01-01

    Many mentally retarded autistic children can understand the concept of object permanence, but, in comparison to developmental-age matched normal children, the behavioral strategies they employ in carrying out the Casati-Lezine Object Permanence Test are deficient and lead to failure. These deficiencies appear unrelated to interference of stereotypic or other bizarre behavior in task performance. Similar problem-solving deficiencies can be found in mentally retarded children who are not autistic, suggesting that the deficiencies themselves are less related to the social-communication deficits of autistic children, but more to the general problem-solving difficulties found in children with a lower developmental quotient. Nevertheless, the qualitative analysis of results shows a tendency in autistic children, despite their better developmental level, to use less coordinated and regular sequences to solve the task than normal or mentally retarded children.

  5. Lawful Permanent Residents - Annual Report

    Data.gov (United States)

    Department of Homeland Security — A lawful permanent resident (LPR) or 'green card' recipient is defined by immigration law as a person who has been granted lawful permanent residence in the United...

  6. 21 CFR 886.4445 - Permanent magnet.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Permanent magnet. 886.4445 Section 886.4445 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4445 Permanent magnet. (a) Identification. A permanent magnet is a nonelectric device that generates a magnetic field intended to find and remove metallic...

  7. Effects of Appropriate Prolonged Sacral Neuromodulation Testing in Improving Implantation Rate of a Permanent Implantable Pulse Generator in Patients with Refractory Lower Urinary Tract Dysfunctions in Mainland China

    Directory of Open Access Journals (Sweden)

    Peng Zhang

    2017-01-01

    Results: Among 51 patients receiving SNM therapy, 19 patients (mean age 45.0 ± 16.9 years had poor Stage I test results, and on an average, the electrode was removed 27.4 ± 9.6 days after the surgery. In one patient, the electrode was removed within 2 weeks; when the remaining 18 patients were questioned 2 weeks after testing, none of the patients wanted to terminate the test, and all the 18 patients desired to prolong the testing time to further observe the treatment effect. The remaining 32 patients (mean age 46.7 ± 15.3 years received Stage II permanent implantation at 19.6 ± 10.4 days after the surgery. The overall Stage I–II conversion was 62.7% (32/51 in this study. Within 2 weeks after the surgery, only eight patients received Stage II permanent implantation, and the conversion rate was only 15.7% (8/51, which was much lower than the overall conversion rate of 62.7%. Nearly 84.4% (27/32 of the patients received Stage II implantation within 4 weeks. None of the patients had incision infections. In one patient, the entire system was removed 1 month after Stage II implantation due to pain in the implantation site. Conclusions: Appropriate extension of the Stage I testing time of an SNM-barbed electrode could significantly improve the Stage II permanent implantation rate in Chinese refractory LUTS patients; there were no wound infections, and the postoperative complication rate was low. This study recommended that Stage I period of SNM therapy should be 4 weeks according to safety and successful conversion rate.

  8. Dental age estimation in Japanese individuals combining permanent teeth and third molars.

    Science.gov (United States)

    Ramanan, Namratha; Thevissen, Patrick; Fleuws, Steffen; Willems, G

    2012-12-01

    The study aim was, firstly, to verify the Willems et al. model on a Japanese reference sample. Secondly to develop a Japanese reference model based on the Willems et al. method and to verify it. Thirdly to analyze the age prediction performance adding tooth development information of third molars to permanent teeth. Retrospectively 1877 panoramic radiographs were selected in the age range between 1 and 23 years (1248 children, 629 sub-adults). Dental development was registered applying Demirjian 's stages of the mandibular left permanent teeth in children and Köhler stages on the third molars. The children's data were, firstly, used to validate the Willems et al. model (developed a Belgian reference sample), secondly, split ino a training and a test sample. On the training sample a Japanese reference model was developed based on the Willems method. The developed model and the Willems et al; model were verified on the test sample. Regression analysis was used to detect the age prediction performance adding third molar scores to permanent tooth scores. The validated Willems et al. model provided a mean absolute error of 0.85 and 0.75 years in females and males, respectively. The mean absolute error in the verified Willems et al. and the developed Japanese reference model was 0.85, 0.77 and 0.79, 0.75 years in females and males, respectively. On average a negligible change in root mean square error values was detected adding third molar scores to permanent teeth scores. The Belgian sample could be used as a reference model to estimate the age of the Japanese individuals. Combining information from the third molars and permanent teeth was not providing clinically significant improvement of age predictions based on permanent teeth information alone.

  9. HIT or miss? A comprehensive contemporary investigation of laboratory tests for heparin induced thrombocytopenia.

    Science.gov (United States)

    Favaloro, Emmanuel J; McCaughan, Georgia; Mohammed, Soma; Lau, Kun Kan Edwin; Gemmell, Rosalie; Cavanaugh, Lauren; Donikian, Dea; Kondo, Mayuko; Brighton, Timothy; Pasalic, Leonardo

    2018-04-17

    Heparin induced thrombocytopenia (HIT) is a rare but potentially fatal complication of heparin therapy, which in a proportion of patients causes platelet activation and thrombosis. Initial clinical assessment of the likelihood of HIT is facilitated by laboratory testing to confirm or exclude HIT. This prospective investigation was performed over an 18-month period, and has involved testing of over 300 test samples from over 100 consecutive patients. Clinical assessment by 4T score was supplemented by laboratory tests that comprised both immunological [lateral flow ('STiC'), chemiluminescence (AcuStar; HIT-IgG (PF4-H) ), ELISA (Asserachrom HPIA IgG)] and functional assays [SRA, platelet aggregation using whole blood ('Multiplate') and platelet rich plasma ('LTA')]. We observed both false positive and false negative test findings with most assays. Overall, the whole blood aggregation method provided a reasonable alternative to SRA for identifying functional HIT. STiC, AcuStar and ELISA procedures were fairly comparable in terms of screening for HIT, although STiC and AcuStar both yielded false negatives, albeit also resulting in fewer false positives than ELISA. The 4T score had less utility in our patient cohort than we were expecting, although there was an association with the likelihood of HIT. Nevertheless, we accept that our observations are based on limited test numbers. In conclusion, no single approach (clinical or laboratory) was associated with optimal sensitivity or specificity of HIT exclusion or identification, and thus, a combination of clinical evaluation and laboratory testing will best ensure the accuracy of diagnosis. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  10. Designing a Virtual laboratory for Simulating to Production of Nanocomposite NdFeB Magnets

    Directory of Open Access Journals (Sweden)

    Musa Faruk Çakir

    2014-02-01

    Full Text Available The talent figure for a permanent magnet is the multiplication of the maximum energy (BHmax. Less volume magnet is required for the production of magnet flux density if the BHmax value is higher. Mathematical functions are obtained from the data related to resiudal flux density, magnetic coercitivy, permanent magnet flux product capability, Curie temperature and density which were obtained as a result of the studies on different NdFeB alloys in the laboratory. Besides this, mathematical functions of NdFeB hard magnet’s resiudal flux density are obtained by adding elements. In this study, a virtual laboratory for producing nanocompositedNdFeB magnet has been designed. The virtual laboratory software has been used to simulate NdFeB hard magnets for industrial utilities.

  11. Development of Piagetian object permanence in a grey parrot (Psittacus erithacus).

    Science.gov (United States)

    Pepperberg, I M; Willner, M R; Gravitz, L B

    1997-03-01

    The authors evaluated the ontogenetic performance of a grey parrot (Psittacus erithacus) on object permanence tasks designed for human infants. Testing began when the bird was 8 weeks old, prior to fledging and weaning. Because adult grey parrots understand complex invisible displacements (I. M. Pepperberg & F. A. Kozak, 1986), the authors continued weekly testing until the current subject completed all of I. C. Uzgiris and J. Hunt's (1975) Scale 1 tasks. Stage 6 object permanence with respect to these tasks emerged at 22 weeks, after the bird had fledged but before it was completely weaned. Although the parrot progressed more rapidly overall than other species that have been tested ontogenetically, the subject similarly exhibited a behavioral plateau part way through the study. Additional tests, administered at 8 and 12 months as well as to an adult grey parrot, demonstrated, respectively, that these birds have some representation of a hidden object and understand advanced invisible displacements.

  12. Long-term climate change assessment study plan for the Hanford Site Permanent Isolation Barrier Development Program

    International Nuclear Information System (INIS)

    Petersen, K.L.; Chatters, J.C.; Waugh, W.J.

    1993-05-01

    The Hanford Site Permanent Isolation Barrier Development Program (Barrier Development Program) was organized to develop the technology needed to provide an in-place disposal capability for low-level nuclear waste for the US Department of Energy at the Hanford Site in south-central Washington. The goal of the Barrier Development Program is to provide defensible evidence that final barrier design(s) will adequately control water infiltration, plant and animal intrusion, and wind and water erosion for a minimum of 1,000 yr; to isolate wastes from the accessible environment; and to use markers to warn inadvertent human intruders. Evidence for barrier performance will be obtained by conducting laboratory experiments, field tests, computer modeling, and other studies that establish confidence in the barrier's ability to meet its 1,000-yr design life

  13. [Permanent education in health: a review].

    Science.gov (United States)

    Miccas, Fernanda Luppino; Batista, Sylvia Helena Souza da Silva

    2014-02-01

    To undertake a meta-synthesis of the literature on the main concepts and practices related to permanent education in health. A bibliographical search was conducted for original articles in the PubMed, Web of Science, LILACS, IBECS and SciELO databases, using the following search terms: "public health professional education", "permanent education", "continuing education", "permanent education health". Of the 590 articles identified, after applying inclusion and exclusion criteria, 48 were selected for further analysis, grouped according to the criteria of key elements, and then underwent meta-synthesis. The 48 original publications were classified according to four thematic units of key elements: 1) concepts, 2) strategies and difficulties, 3) public policies and 4) educational institutions. Three main conceptions of permanent education in health were found: problem-focused and team work, directly related to continuing education and education that takes place throughout life. The main strategies for executing permanent education in health are discussion, maintaining an open space for permanent education , and permanent education clusters. The most limiting factor is mainly related to directly or indirect management. Another highlight is the requirement for implementation and maintenance of public policies, and the availability of financial and human resources. The educational institutions need to combine education and service aiming to form critical-reflexive graduates. The coordination between health and education is based as much on the actions of health services as on management and educational institutions. Thus, it becomes a challenge to implement the teaching-learning processes that are supported by critical-reflexive actions. It is necessary to carry out proposals for permanent education in health involving the participation of health professionals, teachers and educational institutions. To undertake a meta-synthesis of the literature on the main concepts and

  14. Modeling of a Permanent Magnet Linear Generator for Wave-Energy Conversion

    KAUST Repository

    Tom, Nathan; Son, Daewoong; Belissen, Valentin; Yeung, Ronald W.

    2015-01-01

    © 2015 by ASME. This paper begins with a brief review of the equation of motion for a generic floating body with modification to incorporate the influence of a power-take-off (PTO) unit. Since the damping coefficient is considered the dominant contribution to the PTO reaction force, the optimum non time-varying values are presented for all frequencies, recovering the well-known impedance-matching principle at the resonance condition of the coupled system. The construction of a laboratory-scale permanent magnet linear generator (PMLG), developed at the University of California at Berkeley, is discussed along with the basic electromagnetic equations used to model its performance. Modeling of the PMLG begins with a lumped magnetic circuit analysis, which provides an analytical solution to predict the magnetic flux available for power conversion. The voltage generated across each phase of the stator, induced by the motion of the armature, provides an estimate for the electromagnetic damping as a function of the applied resistive load. The performance of the PMLG and the validation of the proposed analytical model is completed by a set of dry-bench tests. Results from the bench test showed good agreement with the described electromechanical model, thus providing an analytical solution that can assist in further optimization of the PMLG.

  15. Modeling of a Permanent Magnet Linear Generator for Wave-Energy Conversion

    KAUST Repository

    Tom, Nathan

    2015-05-31

    © 2015 by ASME. This paper begins with a brief review of the equation of motion for a generic floating body with modification to incorporate the influence of a power-take-off (PTO) unit. Since the damping coefficient is considered the dominant contribution to the PTO reaction force, the optimum non time-varying values are presented for all frequencies, recovering the well-known impedance-matching principle at the resonance condition of the coupled system. The construction of a laboratory-scale permanent magnet linear generator (PMLG), developed at the University of California at Berkeley, is discussed along with the basic electromagnetic equations used to model its performance. Modeling of the PMLG begins with a lumped magnetic circuit analysis, which provides an analytical solution to predict the magnetic flux available for power conversion. The voltage generated across each phase of the stator, induced by the motion of the armature, provides an estimate for the electromagnetic damping as a function of the applied resistive load. The performance of the PMLG and the validation of the proposed analytical model is completed by a set of dry-bench tests. Results from the bench test showed good agreement with the described electromechanical model, thus providing an analytical solution that can assist in further optimization of the PMLG.

  16. Hot Corrosion Test Facility at the NASA Lewis Special Projects Laboratory

    Science.gov (United States)

    Robinson, Raymond C.; Cuy, Michael D.

    1994-01-01

    The Hot Corrosion Test Facility (HCTF) at the NASA Lewis Special Projects Laboratory (SPL) is a high-velocity, pressurized burner rig currently used to evaluate the environmental durability of advanced ceramic materials such as SiC and Si3N4. The HCTF uses laboratory service air which is preheated, mixed with jet fuel, and ignited to simulate the conditions of a gas turbine engine. Air, fuel, and water systems are computer-controlled to maintain test conditions which include maximum air flows of 250 kg/hr (550 lbm/hr), pressures of 100-600 kPa (1-6 atm), and gas temperatures exceeding 1500 C (2732 F). The HCTF provides a relatively inexpensive, yet sophisticated means for researchers to study the high-temperature oxidation of advanced materials, and the injection of a salt solution provides the added capability of conducting hot corrosion studies.

  17. The application of data from proficiency testing to laboratory accreditation according to ISO 17025

    DEFF Research Database (Denmark)

    Heydorn, Kaj

    2008-01-01

    Current methods of testing laboratories for their proficiency in reporting correct measurement results are liable to substantial errors of the 2nd kind. This means that laboratories with deflated uncertainties are accepted as proficient, even though their reported measurement results pave the way...

  18. DEPIVIH 2: Use of three HIV testing methods in French primary care settings - ELISA laboratory screening versus two rapid point-of-care HIV tests.

    Science.gov (United States)

    Papadima, D; Gauthier, R; Prévoteau du Clary, F; Bouée, S; Conort, G; Livrozet, J-M; Taulera, O; Wajsbrot, A; Majerholc, C; Peter, J-M; Aubert, J-P

    2018-03-01

    The primary endpoint was to evaluate the use of HIV testing methods by French primary care providers: Elisa laboratory screening, instant result HIV diagnostic test and rapid result HIV diagnostic test. The secondary endpoints were the population screening rate of unknown HIV status consulting during the study period, reasons for screening and for choosing the specific screening method, the investigators' satisfaction with the rapid diagnostic test (RDT) and problems encountered. National prospective interventional study with French family physicians (FP) from December 2013 to December 2014. FPs enrolled all consenting adults consulting for an HIV screening test during a 6-month period: the choice was an Elisa laboratory test or one of the two RDTs. During the study period, 43 FPs included 981 patients. HIV screening was performed for the first time for 31.6% of patients; 767 (78.2%) Elisa laboratory test prescriptions and 214 (21.8%) RDTs were performed, leading to a screening rate of 1.3%. For 120 (15.7%) of the Elisa laboratory tests, the result was not reported and six RDTs were not valid. Nine patients were diagnosed as HIV-infected (0.9%): five with Elisa laboratory test and four with RDT. Almost 90% of FPs were willing to keep on using RDTs in their daily practice. In general practice, RDTs may be an important additional tool to traditional HIV screening. They could account for one in five tests prescribed in this context. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  19. SUSCEPTIBILITY TEST FOR FUNGI: CLINICAL AND LABORATORIAL CORRELATIONS IN MEDICAL MYCOLOGY

    Directory of Open Access Journals (Sweden)

    Ana ALASTRUEY-IZQUIERDO

    2015-09-01

    Full Text Available SUMMARYDuring recent decades, antifungal susceptibility testing has become standardized and nowadays has the same role of the antibacterial susceptibility testing in microbiology laboratories. American and European standards have been developed, as well as equivalent commercial systems which are more appropriate for clinical laboratories. The detection of resistant strains by means of these systems has allowed the study and understanding of the molecular basis and the mechanisms of resistance of fungal species to antifungal agents. In addition, many studies on the correlation of in vitro results with the outcome of patients have been performed, reaching the conclusion that infections caused by resistant strains have worse outcome than those caused by susceptible fungal isolates. These studies have allowed the development of interpretative breakpoints for Candida spp. and Aspergillus spp., the most frequent agents of fungal infections in the world. In summary, antifungal susceptibility tests have become essential tools to guide the treatment of fungal diseases, to know the local and global disease epidemiology, and to identify resistance to antifungals.

  20. Laboratory compliance with the American Society of Clinical Oncology/college of American Pathologists guidelines for human epidermal growth factor receptor 2 testing: a College of American Pathologists survey of 757 laboratories.

    Science.gov (United States)

    Nakhleh, Raouf E; Grimm, Erin E; Idowu, Michael O; Souers, Rhona J; Fitzgibbons, Patrick L

    2010-05-01

    To ensure quality human epidermal growth receptor 2 (HER2) testing in breast cancer, the American Society of Clinical Oncology/College of American Pathologists guidelines were introduced with expected compliance by 2008. To assess the effect these guidelines have had on pathology laboratories and their ability to address key components. In late 2008, a survey was distributed with the HER2 immunohistochemistry (IHC) proficiency testing program. It included questions regarding pathology practice characteristics and assay validation using fluorescence in situ hybridization or another IHC laboratory assay and assessed pathologist HER2 scoring competency. Of the 907 surveys sent, 757 (83.5%) were returned. The median laboratory accessioned 15 000 cases and performed 190 HER2 tests annually. Quantitative computer image analysis was used by 33% of laboratories. In-house fluorescence in situ hybridization was performed in 23% of laboratories, and 60% of laboratories addressed the 6- to 48-hour tissue fixation requirement by embedding tissue on the weekend. HER2 testing was performed on the initial biopsy in 40%, on the resection specimen in 6%, and on either in 56% of laboratories. Testing was validated with only fluorescence in situ hybridization in 47% of laboratories, whereas 10% of laboratories used another IHC assay only; 13% used both assays, and 12% and 15% of laboratories had not validated their assays or chose "not applicable" on the survey question, respectively. The 90% concordance rate with fluorescence in situ hybridization results was achieved by 88% of laboratories for IHC-negative findings and by 81% of laboratories for IHC-positive cases. The 90% concordance rate for laboratories using another IHC assay was achieved by 80% for negative findings and 75% for positive cases. About 91% of laboratories had a pathologist competency assessment program. This survey demonstrates the extent and characteristics of HER2 testing. Although some American Society of

  1. Individual differences in infant fearfulness and cognitive performance: a testing, performance, or competence effect?

    Science.gov (United States)

    Rieser-Danner, Loretta A

    2003-02-01

    The author conducted 2 studies to examine the relations between infant fear and cognitive testing performance in 12-month-old infants. In Study 1, fear was assessed by using 2 standard temperament questionnaires and a laboratory-based, standardized stranger approach. Individual differences in cognitive development were assessed using the Object Permanence Scale of the Infant Psychological Development Scales (I. C. Uzgiris & J. M. Hunt, 1975). All 3 assessments of fear significantly predicted object permanence performance, with correlations ranging from -.32 to -.35. In Study 2, fear was assessed via a maternal report questionnaire, and habituation performance was assessed via a basic-level categorization task. Familiarity with the examiner and with the testing environment was manipulated to test for a familiarity influence on performance. Testing revealed individual differences in both fear and habituation. Results suggest that highly fearful infants required more trials to habituate and were less likely to meet the habituation criterion than infants who were less fearful. Methodological and conceptual implications of these results are discussed.

  2. Periodic permanent magnet focused klystron

    Science.gov (United States)

    Ferguson, Patrick; Read, Michael; Ives, R Lawrence

    2015-04-21

    A periodic permanent magnet (PPM) klystron has beam transport structures and RF cavity structures, each of which has permanent magnets placed substantially equidistant from a beam tunnel formed about the central axis, and which are also outside the extent of a cooling chamber. The RF cavity sections also have permanent magnets which are placed substantially equidistant from the beam tunnel, but which include an RF cavity coupling to the beam tunnel for enhancement of RF carried by an electron beam in the beam tunnel.

  3. Evaluation of spontaneous space closure and development of permanent dentition after extraction of hypomineralized permanent first molars.

    Science.gov (United States)

    Jälevik, Birgitta; Möller, Marie

    2007-09-01

    The aim of this study was to evaluate spontaneous space closure, development of the permanent dentition, and need for orthodontic treatment after extraction of permanent first molars due to severe molar-incisor hypomineralization (MIH). Twenty-seven children aged 5.6-12.7 (median 8.2) years had one to four permanent first molars extracted due to severe MIH. Each case was followed up on individual indications 3.8-8.3 (median 5.7) years after extractions. The eruption of the permanent dentition, and space closure were documented by orthopantomograms, casts, photographs, and/or bitewings. Fifteen children were judged to have a favourable spontaneous development of their permanent dentition without any orthodontic intervention. Seven children were or should be subjected to orthodontic treatment for other reasons registered prior to the extraction. Five children were judged to have a treatment at least caused by the extractions, but three of them abstained because of no subjective treatment need. Extraction of permanent first molars severely affected by MIH is a good treatment alternative. Favourable spontaneous space reduction and development of the permanent dentition positioning can be expected without any intervention in the majority of cases extracted prior to the eruption of the second molar.

  4. Modern permanent magnetic materials - preparation and properties

    International Nuclear Information System (INIS)

    Rodewald, W.

    1989-01-01

    First of all, the basic properties of the classical (steel, AlNiCo) permanent magnetic materials and the modern rare-earth (RE) permanent magnetic materials are compared. Since the properties of RE permanent magnets depend on the particular production process, the fundamentals of the main industrial processes (powder metallurgy, rapid-solidification technique) are described and the typical properties are explained. Furthermore the production processes in development such as mechanical alloying, melt spinning technique and extrusion upsetting are briefly outlined. For applying the permanent magnets, they have to be completely magnetized. The magnetization behaviour of the various RE permanent magnets is discussed by means of the internal demagnetization curve. Finally the various influences on the temperature stability of RE permanent magnets are compiled. (orig./MM) [de

  5. Request of laboratory liver tests in primary care in Spain: potential savings if appropriateness indicator targets were achieved.

    Science.gov (United States)

    Salinas, Maria; López-Garrigós, Maite; Flores, Emilio; Uris, Joaquín; Leiva-Salinas, Carlos

    2015-10-01

    Liver laboratory tests are used to screen for liver disease, suggest the underlying cause, estimate the severity, assess prognosis, and monitor the efficacy of therapy. The aim of this study was to compare the liver laboratory tests requesting patterns by GPs in Spain, according to geographic and hospital characteristics, to investigate the degree of requesting appropriateness. One hundred and forty-one clinical laboratories were invited to participate from diverse regions across Spain. They filed out the number of laboratory liver tests requested by GPs for the year 2012. Two types of appropriateness indicators were calculated: every test request per 1000 inhabitants or ratios of related tests requests. The indicator results obtained were compared between the different hospitals, according to their setting, location, and management. The savings generated, if each area would have achieved indicator targets, were calculated. We recruited 76 laboratories covering a population of 17,679,195 inhabitants. GPs requested 20,916,780 laboratory liver tests in the year 2012. No differences were obtained according to their setting. Lactate dehydrogenase and direct bilirubin per 1000 inhabitants were significantly higher in institutions with private management. Largest differences were observed between communities. Nine, 31, 0, and 13 laboratories, respectively, achieved the aspartate aminotransferase, lactate dehydrogenase, γ-glutamyl transpeptidase, and total bilirubin-related alanine aminotransferase indicator targets. Reaching ratios would have resulted in savings of €1,028,468. There was a high variability in the request of liver tests. This emphasizes the need to implement interventions to improve appropriate use of liver tests.

  6. Lawful Permanent Residents Fiscal Year 2015 State

    Data.gov (United States)

    Department of Homeland Security — Lawful permanent residents (LPRs) are foreign nationals who have been granted the right to reside permanently in the United States. LPRs are also known as 'permanent...

  7. Lawful Permanent Residents Fiscal Year 2014 Country

    Data.gov (United States)

    Department of Homeland Security — Lawful permanent residents (LPRs) are foreign nationals who have been granted the right to reside permanently in the United States. LPRs are also known as 'permanent...

  8. Lawful Permanent Residents Fiscal Year 2011 State

    Data.gov (United States)

    Department of Homeland Security — Lawful permanent residents (LPRs) are foreign nationals who have been granted the right to reside permanently in the United States. LPRs are also known as 'permanent...

  9. Lawful Permanent Residents Fiscal Year 2015 Country

    Data.gov (United States)

    Department of Homeland Security — Lawful permanent residents (LPRs) are foreign nationals who have been granted the right to reside permanently in the United States. LPRs are also known as 'permanent...

  10. Lawful Permanent Residents Fiscal Year 2016 State

    Data.gov (United States)

    Department of Homeland Security — Lawful permanent residents (LPRs) are foreign nationals who have been granted the right to reside permanently in the United States. LPRs are also known as 'permanent...

  11. Lawful Permanent Residents Fiscal Year 2014 State

    Data.gov (United States)

    Department of Homeland Security — Lawful permanent residents (LPRs) are foreign nationals who have been granted the right to reside permanently in the United States. LPRs are also known as 'permanent...

  12. Object permanence in orangutans (Pongo pygmaeus) and squirrel monkeys (Saimiri sciureus).

    Science.gov (United States)

    de Blois, S T; Novak, M A; Bond, M

    1998-06-01

    The authors tested orangutans (Pongo pygmaeus) and squirrel monkeys (Saimiri sciureus) on object permanence tasks. In Experiment 1, orangutans solved all visible displacements and most invisible displacements except those involving movements into 2 boxes successively. In Experiment 2, performance of orangutans on double invisible displacements and control displacements (assessing simple strategies) was compared. Orangutans did not use the simple strategy of selecting the box visited last by the experimenter. Instead, poorer performance on double invisible displacements may have been related to increased memory requirements. In Experiment 3, squirrel monkeys were tested using the procedure of Experiment 1. Squirrel monkeys solved visible but did not comprehend invisible displacements. Results suggest that orangutans but not squirrel monkeys possess Stage 6 object permanence capabilities.

  13. Hanford Permanent Isolation Barrier Program: Asphalt technology development

    International Nuclear Information System (INIS)

    Freeman, H.D.; Romine, R.A.

    1994-11-01

    An important component of the Hanford Permanent Isolation Barrier is the use of a two-layer composite asphalt system, which provides backup water diversion capabilities if the primary capillary barrier fails to meet infiltration goals. Because of asphalt's potential to perform to specification over the 1000-year design life criterion, a composite asphalt barrier (HMAC/fluid-applied polymer-modified asphalt) is being considered as an alternative to the bentonite clay/high density poly(ethylene) barriers for the low-permeability component of the Hanford Permanent Isolation Barrier. The feasibility of using asphalt as a long-term barrier is currently being studied. Information that must be known is the ability of asphalt to retain desirable physical properties over a period of 1000 years. This paper presents the approach for performing accelerated aging tests and evaluating the performance of samples under accelerated conditions. The results of these tests will be compared with asphalt artifact analogs and the results of modeling the degradation of the selected asphalt composite to make life-cycle predictions

  14. 40 CFR 1048.510 - What transient duty cycles apply for laboratory testing?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false What transient duty cycles apply for... Procedures § 1048.510 What transient duty cycles apply for laboratory testing? (a) Starting with the 2007 model year, measure emissions by testing the engine on a dynamometer with the duty cycle described in...

  15. Technical baseline description for in situ vitrification laboratory test equipment

    International Nuclear Information System (INIS)

    Beard, K.V.; Bonnenberg, R.W.; Watson, L.R.

    1991-09-01

    IN situ vitrification (ISV) has been identified as possible waste treatment technology. ISV was developed by Pacific Northwest Laboratory (PNL), Richland, Washington, as a thermal treatment process to treat contaminated soils in place. The process, which electrically melts and dissolves soils and associated inorganic materials, simultaneously destroys and/or removes organic contaminants while incorporating inorganic contaminants into a stable, glass-like residual product. This Technical Baseline Description has been prepared to provide high level descriptions of the design of the Laboratory Test model, including all design modifications and safety improvements made to data. Furthermore, the Technical Baseline Description provides a basic overview of the interface documents for configuration management, program management interfaces, safety, quality, and security requirements. 8 figs

  16. Do sediment type and test durations affect results of laboratory-based, accelerated testing studies of permeable pavement clogging?

    Science.gov (United States)

    Nichols, Peter W B; White, Richard; Lucke, Terry

    2015-04-01

    Previous studies have attempted to quantify the clogging processes of Permeable Interlocking Concrete Pavers (PICPs) using accelerated testing methods. However, the results have been variable. This study investigated the effects that three different sediment types (natural and silica), and different simulated rainfall intensities, and testing durations had on the observed clogging processes (and measured surface infiltration rates) of laboratory-based, accelerated PICP testing studies. Results showed that accelerated simulated laboratory testing results are highly dependent on the type, and size of sediment used in the experiments. For example, when using real stormwater sediment up to 1.18 mm in size, the results showed that neither testing duration, nor stormwater application rate had any significant effect on PICP clogging. However, the study clearly showed that shorter testing durations generally increased clogging and reduced the surface infiltration rates of the models when artificial silica sediment was used. Longer testing durations also generally increased clogging of the models when using fine sediment (<300 μm). Results from this study will help researchers and designers better anticipate when and why PICPs are susceptible to clogging, reduce maintenance and extend the useful life of these increasingly common stormwater best management practices. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Transportable Emissions Testing Laboratory for Alternative Vehicles Emissions Testing

    Energy Technology Data Exchange (ETDEWEB)

    Clark, Nigel

    2012-01-31

    The overall objective of this project was to perform research to quantify and improve the energy efficiency and the exhaust emissions reduction from advanced technology vehicles using clean, renewable and alternative fuels. Advanced vehicle and alternative fuel fleets were to be identified, and selected vehicles characterized for emissions and efficiency. Target vehicles were to include transit buses, school buses, vocational trucks, delivery trucks, and tractor-trailers. Gaseous species measured were to include carbon monoxide, carbon dioxide, oxides of nitrogen, hydrocarbons, and particulate matter. An objective was to characterize particulate matter more deeply than by mass. Accurate characterization of efficiency and emissions was to be accomplished using a state-of-the-art portable emissions measurement system and an accompanying chassis dynamometer available at West Virginia University. These two units, combined, are termed the Transportable Laboratory. An objective was to load the vehicles in a real-world fashion, using coast down data to establish rolling resistance and wind drag, and to apply the coast down data to the dynamometer control. Test schedules created from actual vehicle operation were to be employed, and a specific objective of the research was to assess the effect of choosing a test schedule which the subject vehicle either cannot follow or can substantially outperform. In addition the vehicle loading objective was to be met better with an improved flywheel system.

  18. Laboratory Test Setup for Cyclic Axially Loaded Piles in Sand

    DEFF Research Database (Denmark)

    Thomassen, Kristina; Ibsen, Lars Bo; Andersen, Lars Vabbersgaard

    2017-01-01

    This paper presents a comprehensive description and the considerations regarding the design of a new laboratory test setup for testing cyclic axially loaded piles in sand. The test setup aims at analysing the effect of axial one-way cyclic loading on pile capacity and accumulated displacements....... Another aim was to test a large diameter pile segment with dimensions resembling full-scale piles to model the interface properties between pile and sand correctly. The pile segment was an open-ended steel pipe pile with a diameter of 0.5 m and a length of 1 m. The sand conditions resembled the dense sand...... determined from the API RP 2GEO standard and from the test results indicated over consolidation of the sand. Two initial one-way cyclic loading tests provided results of effects on pile capacity and accumulated displacements in agreement with other researchers’ test results....

  19. Testing a Constrained MPC Controller in a Process Control Laboratory

    Science.gov (United States)

    Ricardez-Sandoval, Luis A.; Blankespoor, Wesley; Budman, Hector M.

    2010-01-01

    This paper describes an experiment performed by the fourth year chemical engineering students in the process control laboratory at the University of Waterloo. The objective of this experiment is to test the capabilities of a constrained Model Predictive Controller (MPC) to control the operation of a Double Pipe Heat Exchanger (DPHE) in real time.…

  20. Topology optimized permanent magnet systems

    DEFF Research Database (Denmark)

    Bjørk, Rasmus; Bahl, Christian; Insinga, Andrea Roberto

    2017-01-01

    Topology optimization of permanent magnet systems consisting of permanent magnets, high permeability iron and air is presented. An implementation of topology optimization for magnetostatics is discussed and three examples are considered. The Halbach cylinder is topology optimized with iron...... and an increase of 15% in magnetic efficiency is shown. A topology optimized structure to concentrate a homogeneous field is shown to increase the magnitude of the field by 111%. Finally, a permanent magnet with alternating high and low field regions is topology optimized and a ΛcoolΛcool figure of merit of 0...

  1. Laboratory performance testing of an extruded bitumen containing a surrogate, sodium nitrate-based, low-level aqueous waste

    International Nuclear Information System (INIS)

    Mattus, A.J.; Kaczmarsky, M.M.

    1986-01-01

    Laboratory results of a comprehensive, regulatory performance test program, utilizing an extruded bitumen and a surrogate, sodium nitrate-based waste, have been compiled at the Oak Ridge National Laboratory (ORNL). Using a 53 millimeter, Werner and Pfleiderer extruder, operated by personnel of WasteChem Corporation of Paramus, New Jersey, laboratory-scale, molded samples of type three, air blown bitumen were prepared for laboratory performance testing. A surrogate, low-level, mixed liquid waste, formulated to represent an actual on-site waste at ORNL, containing about 30 wt % sodium nitrate, in addition to eight heavy metals, cold cesium and strontium was utilized. Samples tested contained three levels of waste loading: that is, forty, fifty and sixty wt % salt. Performance test results include the ninety day ANS 16.1 leach test, with leach indices reported for all cations and anions, in addition to the EP Toxicity test, at all levels of waste loading. Additionally, test results presented also include the unconfined compressive strength and surface morphology utilizing scanning electron microscopy. Data presented include correlations between waste form loading and test results, in addition to their relationship to regulatory performance requirements

  2. Laboratory and On-Site Tests for Rapid Runway Repair

    Directory of Open Access Journals (Sweden)

    Federico Leonelli

    2017-11-01

    Full Text Available The attention to rapid pavement repair has grown fast in recent decades: this topic is strategic for the airport management process for civil purposes and peacekeeping missions. This work presents the results of laboratory and on-site tests for rapid runway repair, in order to analyse and compare technical and mechanical performances of 12 different materials currently used in airport. The study focuses on site repairs, a technique adopted most frequently than repairs with modular elements. After describing mechanical and physical properties of the examined materials (2 bituminous emulsions, 5 cement mortars, 4 cold bituminous mixtures and 1 expanding resin, the study presents the results of carried out mechanical tests. The results demonstrate that the best performing material is a one-component fast setting and hardening cement mortar with graded aggregates. This material allows the runway reopening 6 h after the work. A cold bituminous mixture (bicomponent premixed cold asphalt with water as catalyst and the ordinary cement concrete allow the reopening to traffic after 18 h, but both ensure a lower service life (1000 coverages than the cement mortar (10,000 coverages. The obtained results include important information both laboratory level and field, and they could be used by airport management bodies and road agencies when scheduling and evaluating pavement repairs.

  3. Test plan for preparing the Rapid Transuranic Monitoring Laboratory for field deployment

    International Nuclear Information System (INIS)

    McIsaac, C.V.; Sill, C.W.; Gehrke, R.J.; Killian, E.W.; Watts, K.D.

    1994-04-01

    This plan describes experimental work that will be performed during fiscal year 1994 to prepare the Rapid Transuranic Monitoring Laboratory (RTML) for routine field use by US Department of Energy (DOE) Environmental Restoration and Waste Management programs. The RTML is a mobile, field-deployable laboratory developed at the Idaho National Engineering Laboratory (INEL) that provides a rapid, cost-effective means of characterizing and monitoring radioactive waste remediation sites for low-level radioactive contaminants. Analytical instruments currently installed in the RTML include an extended-range, germanium photon analysis spectrometer with an automatic sample changer; two, large-area, ionization chamber alpha spectrometers; and four alpha continuous air monitors. The RTML was field tested at the INEL during June 1993 in conjunction with the Buried Waste Integrated Demonstration's remote retrieval demonstration. The major tasks described in this test plan are to (a) evaluate the beta detectors for use in screening soil samples for 90 Sr, (b) upgrade the alpha spectral analysis software programs, and (c) upgrade the photon spectral analysis software programs

  4. Bottom-up laboratory testing of the DKIST Visible Broadband Imager (VBI)

    Science.gov (United States)

    Ferayorni, Andrew; Beard, Andrew; Cole, Wes; Gregory, Scott; Wöeger, Friedrich

    2016-08-01

    The Daniel K. Inouye Solar Telescope (DKIST) is a 4-meter solar observatory under construction at Haleakala, Hawaii [1]. The Visible Broadband Imager (VBI) is a first light instrument that will record images at the highest possible spatial and temporal resolution of the DKIST at a number of scientifically important wavelengths [2]. The VBI is a pathfinder for DKIST instrumentation and a test bed for developing processes and procedures in the areas of unit, systems integration, and user acceptance testing. These test procedures have been developed and repeatedly executed during VBI construction in the lab as part of a "test early and test often" philosophy aimed at identifying and resolving issues early thus saving cost during integration test and commissioning on summit. The VBI team recently completed a bottom up end-to-end system test of the instrument in the lab that allowed the instrument's functionality, performance, and usability to be validated against documented system requirements. The bottom up testing approach includes four levels of testing, each introducing another layer in the control hierarchy that is tested before moving to the next level. First the instrument mechanisms are tested for positioning accuracy and repeatability using a laboratory position-sensing detector (PSD). Second the real-time motion controls are used to drive the mechanisms to verify speed and timing synchronization requirements are being met. Next the high-level software is introduced and the instrument is driven through a series of end-to-end tests that exercise the mechanisms, cameras, and simulated data processing. Finally, user acceptance testing is performed on operational and engineering use cases through the use of the instrument engineering graphical user interface (GUI). In this paper we present the VBI bottom up test plan, procedures, example test cases and tools used, as well as results from test execution in the laboratory. We will also discuss the benefits realized

  5. OECD validation study to assess intra- and inter-laboratory reproducibility of the zebrafish embryo toxicity test for acute aquatic toxicity testing

    NARCIS (Netherlands)

    Busquet, F.; Strecker, R.; Rawlings, J.M.; Belanger, S.E.; Braunbeck, T.; Carr, G.J.; Cenijn, P.H.; Fochtman, P.; Gourmelon, A.; Hübler, N.; Kleensang, A.; Knöbel, M.; Kussatz, C.; Legler, J.; Lillicrap, A.; Martínez-Jerónimo, F.; Polleichtner, C.; Rzodeczko, H.; Salinas, E.; Schneider, K.E.; Scholz, S.; van den Brandhof, E.J.; van der Ven, L.T.; Walter-Rohde, S.; Weigt, S.; Witters, H.; Halder, M.

    2014-01-01

    A The OECD validation study of the zebrafish embryo acute toxicity test (ZFET) for acute aquatic toxicity testing evaluated the ZFET reproducibility by testing 20 chemicals at 5 different concentrations in 3 independent runs in at least 3 laboratories. Stock solutions and test concentrations were

  6. Theoretical basis for transfer of laboratory test results of grain size distribution of coal to real object

    Energy Technology Data Exchange (ETDEWEB)

    Sikora, W; Chodura, J [Politechnika Sladska, Gliwice (Poland). Instytut Mechanizacji Gornictwa

    1989-01-01

    Evaluates a method for forecasting size distribution of black coal mined by shearer loaders in one coal seam. Laboratory tests for determining coal comminution during cutting and haulage along the face are analyzed. Methods for forecasting grain size distribution of coal under operational conditions using formulae developed on the basis of laboratory tests are discussed. Recommendations for design of a test stand and test conditions are discussed. A laboratory stand should accurately model operational conditions of coal cutting, especially dimensions of the individual elements of the shearer loader, geometry of the cutting drum and cutting tools, and strength characteristics of the coal seam. 9 refs.

  7. Quality control tests in dose calibrators used in research laboratories of IPEN

    International Nuclear Information System (INIS)

    Kuahara, Lilian T.; Junior, Amaury C.R.; Martins, Elaine W.; Dias, Carla R.; Correa, Eduardo de L.; Potiens, Maria da Penha A.

    2013-01-01

    The aim of this study was to do the intercomparison between two dose calibrators used in research laboratories at IPEN-CNEN / SP, one being the Capinted NPL-CRC, of the Laboratorio de Calibracao de Instrumentos (LCI) do IPEN, and the other Capintec CRC-15R of the Centro de Radiofarmacia (CR). The standard sources used for carrying out the comparing tests between the two laboratories were 57 Co, 133 Ba and the 13 7 C s

  8. Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing

    Science.gov (United States)

    Espy, M. J.; Uhl, J. R.; Sloan, L. M.; Buckwalter, S. P.; Jones, M. F.; Vetter, E. A.; Yao, J. D. C.; Wengenack, N. L.; Rosenblatt, J. E.; Cockerill, F. R.; Smith, T. F.

    2006-01-01

    Real-time PCR has revolutionized the way clinical microbiology laboratories diagnose many human microbial infections. This testing method combines PCR chemistry with fluorescent probe detection of amplified product in the same reaction vessel. In general, both PCR and amplified product detection are completed in an hour or less, which is considerably faster than conventional PCR detection methods. Real-time PCR assays provide sensitivity and specificity equivalent to that of conventional PCR combined with Southern blot analysis, and since amplification and detection steps are performed in the same closed vessel, the risk of releasing amplified nucleic acids into the environment is negligible. The combination of excellent sensitivity and specificity, low contamination risk, and speed has made real-time PCR technology an appealing alternative to culture- or immunoassay-based testing methods for diagnosing many infectious diseases. This review focuses on the application of real-time PCR in the clinical microbiology laboratory. PMID:16418529

  9. Speed Sensorless Control of Permanent Magnet Synchronous Motors in Mine Electric Locomotive Drive

    Directory of Open Access Journals (Sweden)

    Yudong LI

    2014-04-01

    Full Text Available This paper presents a novel sensorless control method of permanent magnet synchronous motors a low speed based on a high-frequency voltage signal injection. The approach superimposes a persistent HF voltage signal into the estimated d-axis to get the rotor position error angle-related signal by detecting the corresponding voltage response and current response. Then the rotor position and motor speed are obtained. Theoretical analysis and simulation results demonstrate that the approach can achieve sensorless control of permanent magnet synchronous motors at zero and low speed, ensure good dynamic and static performances, and achieve effective control when applied to servo system. Finally, a test prototype system which used a digital signal processor and space vector pulse width modulation technology has been developed. Experimental results show that the system has better static, the effectiveness and dynamic performance of the adaptive test signals in a sensorless controlled surface-mounted permanent magnet synchronous machines.

  10. Guinea pig maximization tests with formaldehyde releasers. Results from two laboratories

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Boman, A; Hamann, K

    1984-01-01

    The guinea pig maximization test was used to evaluate the sensitizing potential of formaldehyde and 6 formaldehyde releasers (Forcide 78, Germall 115, Grotan BK, Grotan OX, KM 200 and Preventol D2). The tests were carried out in 2 laboratories (Copenhagen and Stockholm), and although we intended...... the procedures to be the same, discrepancies were observed, possibly due to the use of different animal strains, test concentrations and vehicles. The sensitizing potential was in general found to be stronger in Stockholm compared to Copenhagen: formaldehyde sensitized 50% of the guinea pigs in Copenhagen and 95...

  11. International on Workshop Advances in Laboratory Testing & Modelling of Soils and Shales

    CERN Document Server

    Laloui, Lyesse

    2017-01-01

    In this spirit, the ATMSS International Workshop “Advances in Laboratory Testing & Modelling of Soils and Shales” (Villars-sur-Ollon, Switzerland; 18-20 January 2017) has been organized to promote the exchange of ideas, experience and state of the art among major experts active in the field of experimental testing and modelling of soils and shales. The Workshop has been organized under the auspices of the Technical Committees TC-101 “Laboratory Testing”, TC-106 “Unsaturated Soils” and TC-308 “Energy Geotechnics” of the International Society of Soil Mechanics and Geotechnical Engineering. This volume contains the invited keynote and feature lectures, as well as the papers that have been presented at the Workshop. The topics of the lectures and papers cover a wide range of theoretical and experimental research, including unsaturated behaviour of soils and shales, multiphysical testing of geomaterials, hydro–mechanical behaviour of shales and stiff clays, the geomechanical behaviour of the ...

  12. FT-Raman spectroscopy, µ-EDXRF spectrometry, and microhardness analysis of the dentin of primary and permanent teeth.

    Science.gov (United States)

    Torres, Carolina Paes; Miranda Gomes-Silva, Jaciara; Menezes-Oliveira, Maria Angélica Hueb; Silva Soares, Luís Eduardo; Palma-Dibb, Regina Guenka; Borsatto, Maria Cristina

    2018-05-01

    The chemical compositions (organic and inorganic contents) and mechanical behaviors of the dentin of permanent and deciduous teeth were analyzed and compared using X-ray fluorescence spectrometry (µ-EDXRF) Fourier transform Raman spectroscopy (FT-Raman) and a microhardness test (HD). Healthy fresh human primary and permanent molars (n = 10) were selected, The buccal surfaces facing upwards were stabilized in an acrylic plate, flattened, polished, and submitted to the µ-EDXRF, FT-Raman, and HD analysis. The results of the analysis were subjected to ANOVAs and Mann-Whitney U/Student's t multiple comparisons tests. The data showed similar values for the dentin of the primary and permanent teeth in P content, organic content (amide I peak), inorganic content ( PO43- - 430 and 590), and microhardness, Nevertheless, Ca content and Ca/P weight ratio were higher, and the CO32- peak was lower in the dentin of the permanent teeth compared to primary teeth. It be concluded that despite permanent teeth showed more Ca element, both substrates showed similar behavior of chemical and physical properties. © 2018 Wiley Periodicals, Inc.

  13. Using pathology-specific laboratory profiles in Clinical Pathology to reduce inappropriate test requesting: two completed audit cycles

    Science.gov (United States)

    2012-01-01

    Background Systematic reviews have shown that, although well prepared, the Consensus Guidelines have failed to change clinical practice. In the healthcare district of Castelnovo né Monti (Reggio Emilia, Italy), it became necessary for the GPs and Clinical Pathologists to work together to jointly define laboratory profiles. Methods Observational study with two cycles of retrospective audit on test request forms, in a primary care setting. Objectives of the study were to develop pathology-specific laboratory profiles and to increase the number of provisional diagnoses on laboratory test request forms. A Multiprofessional Multidisciplinary Inter-hospital Work Team developed pathology-specific laboratory profiles for more effective test requesting. After 8 training sessions that used a combined strategy with multifaceted interventions, the 23 General Practitioners (GPs) in the trial district (Castelnovo nè Monti) tested the profiles; the 21 GPs in the Puianello district were the control group; all GPs in both districts participated in the trial. All laboratory tests for both healthcare districts are performed at the Laboratory located in the trial district. A baseline and a 1-year audit were performed in both districts on the GPs’ request forms. Results Seven pathology-specific laboratory profiles for outpatients were developed. In the year after the first audit cycle: 1) the number of tests requested in the trial district was distinctly lower than that in the previous year, with a decrease of about 5% (p < 0.001); 2) the provisional diagnosis on the request forms was 52.8% in the trial district and 42% in the control district (P < 0.001); 3) the decrease of the number of tests on each request form was much more marked in the trial district (8.73 vs. 10.77; p < 0.001). Conclusions The first audit cycle showed a significant decrease in the number of tests ordered only in the trial district. The combined strategy used in this study improved the

  14. Mars Science Laboratory Flight Software Boot Robustness Testing Project Report

    Science.gov (United States)

    Roth, Brian

    2011-01-01

    On the surface of Mars, the Mars Science Laboratory will boot up its flight computers every morning, having charged the batteries through the night. This boot process is complicated, critical, and affected by numerous hardware states that can be difficult to test. The hardware test beds do not facilitate testing a long duration of back-to-back unmanned automated tests, and although the software simulation has provided the necessary functionality and fidelity for this boot testing, there has not been support for the full flexibility necessary for this task. Therefore to perform this testing a framework has been build around the software simulation that supports running automated tests loading a variety of starting configurations for software and hardware states. This implementation has been tested against the nominal cases to validate the methodology, and support for configuring off-nominal cases is ongoing. The implication of this testing is that the introduction of input configurations that have yet proved difficult to test may reveal boot scenarios worth higher fidelity investigation, and in other cases increase confidence in the robustness of the flight software boot process.

  15. Brookhaven National Laboratory electron beam test stand

    International Nuclear Information System (INIS)

    Pikin, A.; Alessi, J.; Beebe, E.; Kponou, A.; Prelec, K.; Snydstrup, L.

    1998-01-01

    The main purpose of the electron beam test stand (EBTS) project at the Brookhaven National Laboratory is to build a versatile device to develop technologies that are relevant for a high intensity electron beam ion source (EBIS) and to study the physics of ion confinement in a trap. The EBTS will have all the main attributes of EBIS: a 1-m-long, 5 T superconducting solenoid, electron gun, drift tube structure, electron collector, vacuum system, ion injection system, appropriate control, and instrumentation. Therefore it can be considered a short prototype of an EBIS for a relativistic heavy ion collider. The drift tube structure will be mounted in a vacuum tube inside a open-quotes warmclose quotes bore of a superconducting solenoid, it will be at room temperature, and its design will employ ultrahigh vacuum technology to reach the 10 -10 Torr level. The first gun to be tested will be a 10 A electron gun with high emission density and magnetic compression of the electron beam. copyright 1998 American Institute of Physics

  16. Marxism as permanent revolution

    OpenAIRE

    van Ree, E.

    2013-01-01

    This article argues that the 'permanent revolution' represented the dominant element in Karl Marx and Friedrich Engels' political discourse, and that it tended to overrule considerations encapsulated in 'historical materialism'. In Marx and Engels's understanding, permanent revolution did not represent a historical shortcut under exceptional circumstances, but the course revolutions in the modern era would normally take. Marx and Engels traced back the pattern to the sixteenth century. It is ...

  17. The effect of sealer and water storage on permanent deformation of a tissue conditioner

    Directory of Open Access Journals (Sweden)

    Rafael Leonardo Xediek Consani

    2008-01-01

    Full Text Available When they are used to treat inflamed, irritated, or distorted tissues or in implant therapy, tissue conditioners are required to function over relatively long time periods. Purpose: This in vitro study evaluated the effect of sealer and water storage on permanent deformation one tissue conditioner. Material and methods: Sixty cylindrically-shaped specimens (12.7-mm diameter 3 19.0-mm height were used for the deformation tests. Specimens were divided into 6 test groups (n=10, according to surface treatment (sealer application and water storage (1 hour, 1 week and 2 weeks. Permanent deformation, expressed as a percent (%, was determined using ADA specification no. 18. Data were examined a analysis of variance and a Mann-Whitney test (a= 0.05. Results: Significant differences were observed only after 1 week of water storage, for both groups. The surface treated group presented the highest permanent deformation percentage. Conclusions: This in vitro study indicated that the tissue conditioner evaluated is only useful for 1 week. After this period, the material must be replaced.

  18. Comparison of shear bond strength of amalgam bonded to primary and permanent dentin

    Directory of Open Access Journals (Sweden)

    Mahdi S

    2008-06-01

    Full Text Available Amalgam′s non-adhesive characteristics necessitate cavity preparations incorporating retentive features, which often require the removal of non-carious tooth structure. Use of adhesives beneath amalgam restorations, would be helpful to overcome this disadvantage. This study was undertaken to compare the mean shear bond strength of amalgam bonded to primary and permanent dentin, to evaluate the efficacy of amalgam adhesives in pediatric dentistry.27 primary and 28 permanent posterior teeth with intact buccal or lingual surfaces were grounded to expose dentin and wet-polished with 400-grit silicone carbide paper. Scotchbond Multi Purpose Plus adhesive system was applied to the dentin surfaces and light cured. Amalgam was condensed onto the treated dentin through a plastic mold.shear bond strength testing was done using an Instron Universal testing machine, at a crosshead speed of 0.5 mm/min.The data were analyzed by independent samples t-test The difference among the two groups was not statistically significant (p>0.05 Bonded amalgam showed the same level of bond strength to primary and permanent dentin; so, application of amalgam bonding agents in pediatric dentistry can be recommended.

  19. Testing of a cryogenic recooler heat exchanger at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Nicoletti, A.; Wu, K.C.

    1993-01-01

    Brookhaven National Laboratory has tested a recooler heat exchanger intended to be used in the cryogenic system of the Relativistic Heavy Ion Collider. The unit is required to transfer 225 Watts from a supercritical helium stream flowing at 100 g/s to a helium bath boiling at 4.25 K. Measurements made with heat loads of 50 to over 450 Watts on the unit indicate its cooling capacity is greater than 400 Watts, as expected, and it will be suitable for use in the RHIC ring. Presented are the modifications made to BNL's MAGCOOL test facility that were necessary for testing, test procedure, and recooler performance

  20. Canadian Eskimo permanent tooth emergence timing.

    Science.gov (United States)

    Mayhall, J T; Belier, P L; Mayhall, M F

    1978-08-01

    To identify the times of emergence of the permanent teeth of Canadian Eskimos (Inuit), 368 children and adolescents were examined. The presence or absence of all permanent teeth except the third molars was recorded and these data subjected to probit analysis. Female emergence times were advanced over males. Generally, the Inuit of both sexes showed statistically significant earlier emergence times than Montreal children, except for the incisors. The present results do not support hypotheses indicating that premature extraction of the deciduous teeth advances the emergence of their succedaneous counterparts. There is some indication the controls of deciduous tooth emergence continue to play some part in emergence of the permanent dentition, especially the first permanent teeth that emerge.

  1. Multi-Sensor Testing for Automated Rendezvous and Docking Sensor Testing at the Flight Robotics Laboratory

    Science.gov (United States)

    Brewster, L.; Johnston, A.; Howard, R.; Mitchell, J.; Cryan, S.

    2007-01-01

    The Exploration Systems Architecture defines missions that require rendezvous, proximity operations, and docking (RPOD) of two spacecraft both in Low Earth Orbit (LEO) and in Low Lunar Orbit (LLO). Uncrewed spacecraft must perform automated and/or autonomous rendezvous, proximity operations and docking operations (commonly known as AR&D). The crewed missions may also perform rendezvous and docking operations and may require different levels of automation and/or autonomy, and must provide the crew with relative navigation information for manual piloting. The capabilities of the RPOD sensors are critical to the success of the Exploration Program. NASA has the responsibility to determine whether the Crew Exploration Vehicle (CEV) contractor proposed relative navigation sensor suite will meet the requirements. The relatively low technology readiness level of AR&D relative navigation sensors has been carried as one of the CEV Project's top risks. The AR&D Sensor Technology Project seeks to reduce the risk by the testing and analysis of selected relative navigation sensor technologies through hardware-in-the-loop testing and simulation. These activities will provide the CEV Project information to assess the relative navigation sensors maturity as well as demonstrate test methods and capabilities. The first year of this project focused on a series of"pathfinder" testing tasks to develop the test plans, test facility requirements, trajectories, math model architecture, simulation platform, and processes that will be used to evaluate the Contractor-proposed sensors. Four candidate sensors were used in the first phase of the testing. The second phase of testing used four sensors simultaneously: two Marshall Space Flight Center (MSFC) Advanced Video Guidance Sensors (AVGS), a laser-based video sensor that uses retroreflectors attached to the target vehicle, and two commercial laser range finders. The multi-sensor testing was conducted at MSFC's Flight Robotics Laboratory (FRL

  2. 13 CFR 120.900 - Sources of permanent financing.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Sources of permanent financing... Development Company Loan Program (504) Permanent Financing § 120.900 Sources of permanent financing. Permanent financing for each Project must come from three sources: the Borrower's contribution, Third-Party Loans, and...

  3. Inappropriate emergency laboratory test ordering: defensive or peer evidence shared based medicine?

    Directory of Open Access Journals (Sweden)

    C. Descovich

    2013-05-01

    Full Text Available BACKGROUND The laboratory overuse is widely prevalent in hospital practice, mostly in the emergency care. Reasons for excessive and inappropriate test-ordering include defensive behaviour and fear or uncertainty, lack of experience, the misuse of protocols and guidelines, “routine” and local attitudes, inadequate educational feedback and clinician’s unawareness about the cost of examinations and their related implications. AIM OF THE STUDY AND METHODS The primary target of our working group was to reduce inappropriate ordering on a urgent basis test, implementing further examinations not yet previewed in the hospital panel of the available urgencies, according to the evidence based diagnosis concept. The secondary goal was to indicate strategies of re-engineering of the processes, improving turnaround time in the laboratory management of emergencies. After evaluating, as first intervention, the more reliable sources for practice guidelines, systematic reviews and RCTs, the committee further discussed main topics with in-hospital stakeholders, selected from Emergency, Internal Medicine and Surgery Depts. The working group, in many subsequent audits, tried to obtain a systematic feed back with all involved professionals. RESULTS After reviewing literature’s evidence, the board constrained testing options by defining the basic emergency laboratory panel tests (blood type, hemogram, blood urea nitrogen, plasma creatinine, glucose, sodium, potassium, chloride, osmolarity, CRP, bicarbonate, CPK, creatine phosphokinase-MB, myoglobin, troponin, BNP and NT-proBNP, PT-INR, PTT, D-dimer, beta- HCG, biochemical urinalysis etc.. As final result, the proposed tests reduced the overall number of inappropriate investigations and increased, with newer and updated tests, the available panel for critical patients. DISCUSSION A collegiate review of data reporting, in-hospital deepening of problems and the inter- professional discussion of the evidences

  4. Guidelines for establishing quality systems in veterinary diagnostic testing laboratories. Report of a Joint FAO/IAEA consultants meeting/workshop. Draft

    International Nuclear Information System (INIS)

    2002-01-01

    The purpose of this report is to assist veterinary testing laboratories to develop and implement a quality system based on the OIE Standard 'Management and Technical Requirements for Laboratories Conducting Tests for Infectious Animal Diseases'. The introduction to the OIE Standard states: This document describes the OIE Standard for management and technical competence that serves as the basis for accreditation of laboratories that conduct tests for infectious animal diseases, especially those laboratories involved in testing for international trade. It contains the specific requirements unique to laboratories conducting tests for infectious animal diseases. These specific requirements represent an interpretation of the generally stated requirements of ISO/IEC 17025:1999, General requirements for the competence of testing and calibration laboratories (as outlined in Annex B of ISO/IEC 17025). Accreditation bodies that recognize the competence of such testing laboratories may use this Standard as the basis for their accreditation. This report gives an example-oriented overview of the structure and contents of critical documents and procedures such as Quality Manual (QM), Standard Operating Procedures (SOPs), etc. inherent to a quality system and describes the different stages in the implementation of the OIE Standard. For that reason it can be used as a practical guide for the production of necessary documents but also as a help to determine the status of a laboratory during its journey towards establishing a QS

  5. Impacts of changing hydrology on permanent gully growth: experimental results

    Science.gov (United States)

    Day, Stephanie S.; Gran, Karen B.; Paola, Chris

    2018-06-01

    Permanent gullies grow through head cut propagation in response to overland flow coupled with incision and widening in the channel bottom leading to hillslope failures. Altered hydrology can impact the rate at which permanent gullies grow by changing head cut propagation, channel incision, and channel widening rates. Using a set of small physical experiments, we tested how changing overland flow rates and flow volumes alter the total volume of erosion and resulting gully morphology. Permanent gullies were modeled as both detachment-limited and transport-limited systems, using two different substrates with varying cohesion. In both cases, the erosion rate varied linearly with water discharge, such that the volume of sediment eroded was a function not of flow rate, but of total water volume. This implies that efforts to reduce peak flow rates alone without addressing flow volumes entering gully systems may not reduce erosion. The documented response in these experiments is not typical when compared to larger preexisting channels where higher flow rates result in greater erosion through nonlinear relationships between water discharge and sediment discharge. Permanent gullies do not respond like preexisting channels because channel slope remains a free parameter and can adjust relatively quickly in response to changing flows.

  6. Results from laboratory and field testing of nitrate measuring spectrophotometers

    Science.gov (United States)

    Snazelle, Teri T.

    2015-01-01

    Five ultraviolet (UV) spectrophotometer nitrate analyzers were evaluated by the U.S. Geological Survey (USGS) Hydrologic Instrumentation Facility (HIF) during a two-phase evaluation. In Phase I, the TriOS ProPs (10-millimeter (mm) path length), Hach NITRATAX plus sc (5-mm path length), Satlantic Submersible UV Nitrate Analyzer (SUNA, 10-mm path length), and S::CAN Spectro::lyser (5-mm path length) were evaluated in the HIF Water-Quality Servicing Laboratory to determine the validity of the manufacturer's technical specifications for accuracy, limit of linearity (LOL), drift, and range of operating temperature. Accuracy specifications were met in the TriOS, Hach, and SUNA. The stock calibration of the S::CAN required two offset adjustments before the analyzer met the manufacturer's accuracy specification. Instrument drift was observed only in the S::CAN and was the result of leaching from the optical path insert seals. All tested models, except for the Hach, met their specified LOL in the laboratory testing. The Hach's range was found to be approximately 18 milligrams nitrogen per liter (mg-N/L) and not the manufacturer-specified 25 mg-N/L. Measurements by all of the tested analyzers showed signs of hysteresis in the operating temperature tests. Only the SUNA measurements demonstrated excessive noise and instability in temperatures above 20 degrees Celsius (°C). The SUNA analyzer was returned to the manufacturer at the completion of the Phase II field deployment evaluation for repair and recalibration, and the performance of the sensor improved significantly.

  7. [The Object Permanence Fallacy.] Commentary.

    Science.gov (United States)

    Bradley, Ben S.

    1996-01-01

    Suggests that Greenberg's challenge to the centrality of object permanence in developmental thinking reveals that developmentalists' theories about childhood speak about their own self-images. Notes that developmentalists have been guilty of not only the object permanence fallacy but also the genetic fallacy, or the mistaken belief that describing…

  8. Harmonization of antimicrobial susceptibility testing among veterinary diagnostic laboratories in the five Nordic countries

    DEFF Research Database (Denmark)

    Petersen, A.; Aarestrup, Frank Møller; Hofshagen, Merete

    2003-01-01

    A total of 100 bacterial strains (25 Escherichia coli, 25 Salmonella enterica, 25 Staphylococcus aureus, and 25 Enterococcus strains) and four reference strains were tested for susceptibility toward 8-12 antimicrobial agents in 12 veterinary diagnostic laboratories in the five Nordic countries...... reported as vancomycin resistant. Ten laboratories identified the Enterococcus spp. to species level. All five Enterococcus faecium and 10 Enterococcus faecalis selected from the strain collection at the Danish Veterinary Institute were correctly identified by all laboratories, whereas some problems were...

  9. EFRT M-12 Issue Resolution: Caustic-Leach Rate Constants from PEP and Laboratory-Scale Tests

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, Lenna A.; Rassat, Scot D.; Eslinger, Paul W.; Aaberg, Rosanne L.; Aker, Pamela M.; Golovich, Elizabeth C.; Hanson, Brady D.; Hausmann, Tom S.; Huckaby, James L.; Kurath, Dean E.; Minette, Michael J.; Sundaram, S. K.; Yokuda, Satoru T.

    2010-01-01

    Pacific Northwest National Laboratory (PNNL) has been tasked by Bechtel National Inc. (BNI) on the River Protection Project-Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed, constructed and operated as part of a plan to respond to issue M12, “Undemonstrated Leaching Processes” of the External Flowsheet Review Team (EFRT) issue response plan.( ) The PEP is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes. The PEP replicates the WTP leaching processes using prototypic equipment and control strategies. The PEP also includes non-prototypic ancillary equipment to support the core processing. The work described in this report addresses caustic leaching under WTP conditions, based on tests performed with a Hanford waste simulant. Because gibbsite leaching kinetics are rapid (gibbsite is expected to be dissolved by the time the final leach temperature is reached), boehmite leach kinetics are the main focus of the caustic-leach tests. The tests were completed at the laboratory-scale and in the PEP, which is a 1/4.5-scale mock-up of key PTF process equipment. Two laboratory-scale caustic-leach tests were performed for each of the PEP runs. For each PEP run, unleached slurry was taken from the PEP caustic-leach vessel for one batch and used as feed for both of the corresponding laboratory-scale tests.

  10. Topology optimized permanent magnet systems

    Science.gov (United States)

    Bjørk, R.; Bahl, C. R. H.; Insinga, A. R.

    2017-09-01

    Topology optimization of permanent magnet systems consisting of permanent magnets, high permeability iron and air is presented. An implementation of topology optimization for magnetostatics is discussed and three examples are considered. The Halbach cylinder is topology optimized with iron and an increase of 15% in magnetic efficiency is shown. A topology optimized structure to concentrate a homogeneous field is shown to increase the magnitude of the field by 111%. Finally, a permanent magnet with alternating high and low field regions is topology optimized and a Λcool figure of merit of 0.472 is reached, which is an increase of 100% compared to a previous optimized design.

  11. A Laboratory-Based Evaluation of Four Rapid Point-of-Care Tests for Syphilis

    Science.gov (United States)

    Causer, Louise M.; Kaldor, John M.; Fairley, Christopher K.; Donovan, Basil; Karapanagiotidis, Theo; Leslie, David E.; Robertson, Peter W.; McNulty, Anna M.; Anderson, David; Wand, Handan; Conway, Damian P.; Denham, Ian; Ryan, Claire; Guy, Rebecca J.

    2014-01-01

    Background Syphilis point-of-care tests may reduce morbidity and ongoing transmission by increasing the proportion of people rapidly treated. Syphilis stage and co-infection with HIV may influence test performance. We evaluated four commercially available syphilis point-of-care devices in a head-to-head comparison using sera from laboratories in Australia. Methods Point-of-care tests were evaluated using sera stored at Sydney and Melbourne laboratories. Sensitivity and specificity were calculated by standard methods, comparing point-of-care results to treponemal immunoassay (IA) reference test results. Additional analyses by clinical syphilis stage, HIV status, and non-treponemal antibody titre were performed. Non-overlapping 95% confidence intervals (CI) were considered statistically significant differences in estimates. Results In total 1203 specimens were tested (736 IA-reactive, 467 IA-nonreactive). Point-of-care test sensitivities were: Determine 97.3%(95%CI:95.8–98.3), Onsite 92.5%(90.3–94.3), DPP 89.8%(87.3–91.9) and Bioline 87.8%(85.1–90.0). Specificities were: Determine 96.4%(94.1–97.8), Onsite 92.5%(90.3–94.3), DPP 98.3%(96.5–99.2), and Bioline 98.5%(96.8–99.3). Sensitivity of the Determine test was 100% for primary and 100% for secondary syphilis. The three other tests had reduced sensitivity among primary (80.4–90.2%) compared to secondary syphilis (94.3–98.6%). No significant differences in sensitivity were observed by HIV status. Test sensitivities were significantly higher among high-RPR titre (RPR≥8) (range: 94.6–99.5%) than RPR non-reactive infections (range: 76.3–92.9%). Conclusions The Determine test had the highest sensitivity overall. All tests were most sensitive among high-RPR titre infections. Point-of-care tests have a role in syphilis control programs however in developed countries with established laboratory infrastructures, the lower sensitivities of some tests observed in primary syphilis suggest these would

  12. Operational evaluation of rapid diagnostic testing for Ebola Virus Disease in Guinean laboratories.

    Directory of Open Access Journals (Sweden)

    Amanda VanSteelandt

    Full Text Available Rapid Diagnostic Tests (RDTs for Ebola Virus Disease (EVD at the point of care have the potential to increase access and acceptability of EVD testing and the speed of patient isolation and secure burials for suspect cases. A pilot program for EVD RDTs in high risk areas of Guinea was introduced in October 2015. This paper presents concordance data between EVD RDTs and PCR testing in the field as well as an assessment of the acceptability, feasibility, and quality assurance of the RDT program.Concordance data were compiled from laboratory surveillance databases. The operational measures of the laboratory-based EVD RDT program were evaluated at all 34 sentinel sites in Guinea through: (1 a technical questionnaire filled by the lab technicians who performed the RDTs, (2 a checklist filled by the evaluator during the site visits, and (3 direct observation of the lab technicians performing the quality control test. Acceptability of the EVD RDT was good for technicians, patients, and families although many technicians (69.8% expressed concern for their safety while performing the test. The feasibility of the program was good based on average technician knowledge scores (6.6 out of 8 but basic infrastructure, equipment, and supplies were lacking. There was much room for improvement in quality assurance of the program.The implementation of new diagnostics in weak laboratory systems requires general training in quality assurance, biosafety and communication with patients in addition to specific training for the new test. Corresponding capacity building in terms of basic equipment and a long-term commitment to transfer supervision and quality improvement to national public health staff are necessary for successful implementation.

  13. Teaching Object Permanence: An Action Research Study

    Science.gov (United States)

    Bruce, Susan M.; Vargas, Claudia

    2013-01-01

    "Object permanence," also known as "object concept" in the field of visual impairment, is one of the most important early developmental milestones. The achievement of object permanence is associated with the onset of representational thought and language. Object permanence is important to orientation, including the recognition of landmarks.…

  14. Air Force Research Laboratory Success Stories : A Review of 2004

    Science.gov (United States)

    2004-01-01

    Phase IV performed a waveform characterization of the entire radar system. U Gain in the Electrico i Laboratory System Work sponsored by the AFRL...permanent disability, or death in recreational and professional activities that incorporate speed and agility, like auto racing, motorcycling, and skiing

  15. Correlation of same-visit HbA1c test with laboratory-based measurements: A MetroNet study

    Directory of Open Access Journals (Sweden)

    West Patricia A

    2005-07-01

    Full Text Available Abstract Background Glycated hemoglobin (HbA1c results vary by analytical method. Use of same-visit HbA1c testing methodology holds the promise of more efficient patient care, and improved diabetes management. Our objective was to test the feasibility of introducing a same-visit HbA1c methodology into busy family practice centers (FPC and to calculate the correlation between the same-visit HbA1c test and the laboratory method that the clinical site was currently using for HbA1c testing. Methods Consecutive diabetic patients 18 years of age and older having blood samples drawn for routine laboratory analysis of HbA1c were asked to provide a capillary blood sample for same-visit testing with the BIO-RAD Micromat II. We compared the results of the same-visit test to three different laboratory methods (one FPC used two different laboratories. Results 147 paired samples were available for analysis (73 from one FPC; 74 from the other. The Pearson correlation of Micromat II and ion-exchange HPLC was 0.713 (p Conclusion For each of the laboratory methods, the correlation coefficient was lower than the 0.96 reported by the manufacturer. This might be due to variability introduced by the multiple users of the Micromat II machine. The mean HbA1c results were also consistently lower than those obtained from laboratory analysis. Additionally, the amount of dedicated time required to perform the assay may limit its usefulness in a busy clinical practice. Before introducing a same-visit HbA1c methodology, clinicians should compare the rapid results to their current method of analysis.

  16. Viability testing of material derived from Mycobacterium tuberculosis prior to removal from a containment level-III laboratory as part of a Laboratory Risk Assessment Program.

    Science.gov (United States)

    Blackwood, Kym S; Burdz, Tamara V; Turenne, Christine Y; Sharma, Meenu K; Kabani, Amin M; Wolfe, Joyce N

    2005-01-24

    In the field of clinical mycobacteriology, Mycobacterium tuberculosis (MTB) can be a difficult organism to manipulate due to the restrictive environment of a containment level 3 (CL3) laboratory. Tests for rapid diagnostic work involving smears and molecular methods do not require CL3 practices after the organism has been rendered non-viable. While it has been assumed that after organism deactivation these techniques can be performed outside of a CL3, no conclusive study has consistently confirmed that the organisms are noninfectious after the theoretical 'deactivation' steps. Previous studies have shown that initial steps (such as heating/chemical fixation) may not consistently kill MTB organisms. An inclusive viability study (n = 226) was undertaken to determine at which point handling of culture extraction materials does not necessitate a CL3 environment. Four different laboratory protocols tested for viability included: standard DNA extractions for IS6110 fingerprinting, crude DNA preparations for PCR by boiling and mechanical lysis, protein extractions, and smear preparations. For each protocol, laboratory staff planted a proportion of the resulting material to Bactec 12B medium that was observed for growth for 8 weeks. Of the 208 isolates initially tested, 21 samples grew within the 8-week period. Sixteen (7.7%) of these yielded positive results for MTB that included samples of: deactivated culture resuspensions exposed to 80 degrees C for 20 minutes, smear preparations and protein extractions. Test procedures were consequently modified and tested again (n = 18), resulting in 0% viability. This study demonstrates that it cannot be assumed that conventional practices (i.e. smear preparation) or extraction techniques render the organism non-viable. All methodologies, new and existing, should be examined by individual laboratories to validate the safe removal of material derived from MTB to the outside of a CL3 laboratory. This process is vital to establish in

  17. Viability testing of material derived from Mycobacterium tuberculosis prior to removal from a Containment Level-III Laboratory as part of a Laboratory Risk Assessment Program

    Directory of Open Access Journals (Sweden)

    Kabani Amin M

    2005-01-01

    Full Text Available Abstract Background In the field of clinical mycobacteriology, Mycobacterium tuberculosis (MTB can be a difficult organism to manipulate due to the restrictive environment of a containment level 3 (CL3 laboratory. Tests for rapid diagnostic work involving smears and molecular methods do not require CL3 practices after the organism has been rendered non-viable. While it has been assumed that after organism deactivation these techniques can be performed outside of a CL3, no conclusive study has consistently confirmed that the organisms are noninfectious after the theoretical 'deactivation' steps. Previous studies have shown that initial steps (such as heating /chemical fixation may not consistently kill MTB organisms. Methods An inclusive viability study (n = 226 was undertaken to determine at which point handling of culture extraction materials does not necessitate a CL3 environment. Four different laboratory protocols tested for viability included: standard DNA extractions for IS6110 fingerprinting, crude DNA preparations for PCR by boiling and mechanical lysis, protein extractions, and smear preparations. For each protocol, laboratory staff planted a proportion of the resulting material to Bactec 12B medium that was observed for growth for 8 weeks. Results Of the 208 isolates initially tested, 21 samples grew within the 8-week period. Sixteen (7.7% of these yielded positive results for MTB that included samples of: deactivated culture resuspensions exposed to 80°C for 20 minutes, smear preparations and protein extractions. Test procedures were consequently modified and tested again (n = 18, resulting in 0% viability. Conclusions This study demonstrates that it cannot be assumed that conventional practices (i.e. smear preparation or extraction techniques render the organism non-viable. All methodologies, new and existing, should be examined by individual laboratories to validate the safe removal of material derived from MTB to the outside of a

  18. Intrusive luxation of 60 permanent incisors

    DEFF Research Database (Denmark)

    Tsilingaridis, Georgios; Malmgren, Barbro; Andreasen, Jens O

    2012-01-01

      Intrusive luxation in the permanent dentition is an uncommon injury but it is considered one of the most severe types of dental trauma because of the risk for damage to the periodontal ligament, pulp and alveolar bone. Management of intrusive luxation in the permanent dentition is controversial....... The purpose of this study was to evaluate pulp survival and periodontal healing in intrusive luxated permanent teeth in relation to treatment alternatives, degree of intrusion and root development....

  19. Inquiry-based laboratory investigations and student performance on standardized tests in biological science

    Science.gov (United States)

    Patke, Usha

    Achievement data from the 3rd International Mathematics and Sciences Study and Program for International Student Assessment in science have indicated that Black students from economically disadvantaged families underachieve at alarming rates in comparison to White and economically advantaged peer groups. The study site was a predominately Black, urban school district experiencing underachievement. The purpose of this correlational study was to examine the relationship between students' use of inquiry-based laboratory investigations and their performance on the Biology End of Course Test, as well as to examine the relationship while partialling out the effects of student gender. Constructivist theory formed the theoretical foundation of the study. Students' perceived levels of experience with inquiry-based laboratory investigations were measured using the Laboratory Program Variable Inventory (LPVI) survey. LPVI scores of 256 students were correlated with test scores and were examined by student gender. The Pearson correlation coefficient revealed a small direct correlation between students' experience in inquiry-based laboratory investigation classes and standardized test scores on the Biology EOCT. A partial correlational analysis indicated that the correlation remained after controlling for gender. This study may prompt a change from teacher-centered to student-centered pedagogy at the local site in order to increase academic achievement for all students. The results of this study may also influence administrators and policy makers to initiate local, state, or nationwide curricular development. A change in curriculum may promote social change as students become more competent, and more able, to succeed in life beyond secondary school.

  20. Lawrence Livermore Laboratory's beryllium control program for high-explosive test firing bunkers and tables

    International Nuclear Information System (INIS)

    Johnson, J.S.

    1978-01-01

    This detailed report on Lawrence Livermore Laboratory's control program to minimize beryllium levels in Laboratory workplaces includes an outline of beryllium surface, soil, and air levels and an 11-y summary of sampling results from two high-use, high-explosive test firing bunkers. These sampling data and other studies demonstrate that the beryllium control program is funcioning effectively

  1. Lawrence Berkeley laboratory neutral-beam engineering test facility power-supply system

    International Nuclear Information System (INIS)

    Lutz, I.C.; Arthur, C.A.; deVries, G.J.; Owren, H.M.

    1981-10-01

    The Lawrence Berkeley Laboratory is upgrading the neutral beam source test facility (NBSTF) into a neutral beam engineering test facility (NBETF) with increased capabilities for the development of neutral beam systems. The NBETF will have an accel power supply capable of 170 kV, 70 A, 30 sec pulse length, 10% duty cycle; and the auxiliary power supplies required for the sources. This paper describes the major components, their ratings and capabilities, and the flexibility designed to accomodate the needs of source development

  2. Permanent magnet materials and their application

    International Nuclear Information System (INIS)

    Campbell, P.

    1994-01-01

    Permanent magnets are of great industrial importance in industrial drives, consumer products, computers, and automobiles. Since 1970, new classes of magnet materials have been developed. This book reviews the older and newer materials and is presented as a comprehensive design text for permanent magnets and their applications. After an initial chapter on the fundamentals of magnetism, the author discusses magnetic physics considerations specific to permanent magnets and describes the fabrications and characteristics of commercial materials: alnico, samarium-cobalt, ferrite, and neodymium-iron-boron. Thermal stability, magnet design procedures, magnetic field analysis methods, and measurement methods are discussed in subsequent chapters, followed by a concluding chapter reviewing commercial and industrial products that use permanent magnets. The chapter on thermal properties of magnet materials is of particular interest, bringing together information not readily found elsewhere. The review of applications is also deserving of attention, specifically the sections on motors and actuators. Although particle accelerator applications are discussed, the use of permanent magnet sextuples in modern ECR ion sources is not mentioned

  3. 10 CFR 26.153 - Using certified laboratories for testing urine specimens.

    Science.gov (United States)

    2010-01-01

    ... Workplace Drug Testing Programs [published in the Federal Register on April 11, 1988 (53 FR 11970), and as... current certification status of laboratories is available from the Division of Workplace Programs, Center... relationship with the licensee's or other entity's MRO(s) that may be construed as a potential conflict of...

  4. The bogus taste test: Validity as a measure of laboratory food intake

    OpenAIRE

    Robinson, Eric; Haynes, Ashleigh; Hardman, Charlotte A.; Kemps, Eva; Higgs, Suzanne; Jones, Andrew

    2017-01-01

    Because overconsumption of food contributes to ill health, understanding what affects how much people eat is of importance. The ?bogus? taste test is a measure widely used in eating behaviour research to identify factors that may have a causal effect on food intake. However, there has been no examination of the validity of the bogus taste test as a measure of food intake. We conducted a participant level analysis of 31 published laboratory studies that used the taste test to measure food inta...

  5. Permanent magnets in accelerators can save energy, space and cost

    DEFF Research Database (Denmark)

    Bødker, F.; Baandrup, L.O.; Hauge, N.

    2013-01-01

    coils permit fine tuning of the magnetic field. Magnetic field measurements and thermal stability tests show that the Green Magnet fully meets the magnetic requirements of the previously used electromagnet. A permanent 30° bending dipole is currently being development to demonstrate the use of Green...

  6. Establishing benchmarks and metrics for disruptive technologies, inappropriate and obsolete tests in the clinical laboratory.

    Science.gov (United States)

    Kiechle, Frederick L; Arcenas, Rodney C; Rogers, Linda C

    2014-01-01

    Benchmarks and metrics related to laboratory test utilization are based on evidence-based medical literature that may suffer from a positive publication bias. Guidelines are only as good as the data reviewed to create them. Disruptive technologies require time for appropriate use to be established before utilization review will be meaningful. Metrics include monitoring the use of obsolete tests and the inappropriate use of lab tests. Test utilization by clients in a hospital outreach program can be used to monitor the impact of new clients on lab workload. A multi-disciplinary laboratory utilization committee is the most effective tool for modifying bad habits, and reviewing and approving new tests for the lab formulary or by sending them out to a reference lab. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Multi-laboratory testing of a screening method for world trade center (WTC) collapse dust

    International Nuclear Information System (INIS)

    Rosati, Jacky A.; Bern, Amy M.; Willis, Robert D.; Blanchard, Fredrick T.; Conner, Teri L.; Kahn, Henry D.; Friedman, David

    2008-01-01

    The September 11, 2001 attack on the World Trade Center (WTC) covered a large area of downtown New York City with dust and debris. This paper describes the testing of an analytical method designed to evaluate whether sampled dust contains dust that may have originated from the collapse of the WTC. Using dust samples collected from locations affected and not affected (referred to as 'background' locations) by the collapse, a scanning electron microscopy (SEM) analysis method was developed to screen for three materials that are believed to be present in large quantities in WTC dusts: slag wool, concrete, and gypsum. An inter-laboratory evaluation of the method was implemented by having eight laboratories analyze a number of 'blind' dust samples, consisting of confirmed background dust and confirmed background dust spiked with varying amounts of dust affected by the WTC collapse. The levels of gypsum and concrete in the spiked samples were indistinguishable from the levels in the background samples. Measurements of slag wool in dust demonstrated potential for distinguishing between spiked and background samples in spite of considerable within and between laboratory variability. Slag wool measurements appear to be sufficiently sensitive to distinguish dust spiked with 5% WTC-affected dust from 22 out of 25 background dust samples. Additional development work and inter-laboratory testing of the slag wool component will be necessary to improve the precision and accuracy of the method and reduce inter- and intra-laboratory variability from levels observed in the inter-laboratory evaluation

  8. Nuclear and high-energy physics laboratory - LPNHE. Activity report 2008-2009

    International Nuclear Information System (INIS)

    Pain, Reynald; Guy, Julien; Toussenel, Francois; Laforge, Bertrand; Levy, Jean-Michel; Cossin, Isabelle; Cardot, Violaine

    2011-01-01

    The LPNHE is a joint research unit (UMR 7585) of the National Institute of Nuclear Physics and Particle Physics (IN2P3), Institute of the National Centre for Scientific Research (CNRS), UPMC and Paris Diderot Paris 7. It hosts several research teams and technical services (computers, electronics, mechanical), and two support services (administration, logistics). The laboratory is engaged in several major experimental programs pursued in the framework of international collaborations with very large research facilities around the world, centers of particle accelerators and observatories. The research programs cover current issues in particle physics, astro-particle and cosmology. This report presents the activities of the laboratory during the years 2008-2009: 1 - Forewords; 2 - Highlights; 3 - Research: Masses and FUNDAMENTAL INTERACTIONS; Matter-antimatter asymmetry; Dark matter and dark energy; Cosmic radiation nature and origin; Interdisciplinary activities; Publications, communications; Partnerships; 2 - Teaching, training, internships and PhDs; 3 - Competences and technical realisations (electronics and instrumentation, computers, mechanics departments, test facilities); 4 - Laboratory operation (organisation, financial and human resources, permanent training, communication and library, health and safety, general services, staff); 5 - Scientific life and communication (seminars, meetings..)

  9. Room 209 excavation response test in the underground research laboratory

    International Nuclear Information System (INIS)

    Lang, P.A.

    1989-01-01

    An in situ excavation response test was conducted at the Canadian Underground Research Laboratory (URL) in conjunction with excavation of a tunnel (Room 209) through a near-vertical water-bearing fracture oriented perpendicular to the tunnel axis. Encountering a fracture with such desirable characteristics provided a unique opportunity during construction of the URL to try out instrumentation and analytical methods for use in the Excavation Response Experiment (ERE) planned as one of the major URL experiments. The test has produced a valuable data set for validating numerical models. Four modelling groups predicted the response that would be monitored by the instruments. The predictions of the mechanical response were generally good. However, the predictions of the permeability and hydraulic pressure changes in the fracture, and the water flows into the tunnel, were poor. It is concluded that we may not understand the mechanisms that occur in the fracture in response to excavation. Laboratory testing, and development of a contracting joint code, has been initiated to further investigate this phenomenon. Preliminary results indicate that the excavation damaged zone in the walls and crown is less than 0.5 m thick and has relatively low permeability. The damaged zone in the floor is at least 1 m thick and has relatively high permeability. The damage in the floor could be reduced in future excavations by using controlled blasting methods similar to those used for the walls and crown

  10. Reduced Clostridium difficile Tests and Laboratory-Identified Events With a Computerized Clinical Decision Support Tool and Financial Incentive.

    Science.gov (United States)

    Madden, Gregory R; German Mesner, Ian; Cox, Heather L; Mathers, Amy J; Lyman, Jason A; Sifri, Costi D; Enfield, Kyle B

    2018-06-01

    We hypothesized that a computerized clinical decision support tool for Clostridium difficile testing would reduce unnecessary inpatient tests, resulting in fewer laboratory-identified events. Census-adjusted interrupted time-series analyses demonstrated significant reductions of 41% fewer tests and 31% fewer hospital-onset C. difficile infection laboratory-identified events following this intervention.Infect Control Hosp Epidemiol 2018;39:737-740.

  11. Laboratory testing of waste glass aqueous corrosion; effects of experimental parameters

    International Nuclear Information System (INIS)

    Ebert, W.L.; Mazer, J.J.

    1993-01-01

    A literature survey has been performed to assess the effects of the temperature, glass surface area/leachate volume ratio, leachant composition, leachant flow rate, and glass composition (actual radioactive vs. simulated glass) used in laboratory tests on the measured glass reaction rate. The effects of these parameters must be accounted for in mechanistic models used to project glass durability over long times. Test parameters can also be utilized to highlight particular processes in laboratory tests. Waste glass corrosion results as water diffusion, ion-exchange, and hydrolysis reactions occur simultaneously to devitrify the glass and release soluble glass components into solution. The rates of these processes are interrelated by the affects of the solution chemistry and glass alteration phases on each process, and the dominant (fastest) process may change as the reaction progresses. Transport of components from the release sites into solution may also affect the observed corrosion rate. The reaction temperature will affect the rate of each process, while other parameters will affect the solution chemistry and which processes are observed during the test. The early stages of corrosion will be observed under test conditions which maintain dilute leachates and the later stages will be observed under conditions that generate more concentrated leachate solutions. Typically, water diffusion and ion-exchange reactions dominate the observed glass corrosion in dilute solutions while hydrolysis reactions dominant in more concentrated solutions. Which process(es) controls the long-term glass corrosion is not fully understood, and the long-term corrosion rate may be either transport- or reaction-limited

  12. Experimental Modal Test of the Laboratory Model of Steel Truss Structure

    Directory of Open Access Journals (Sweden)

    Kortiš Ján

    2016-12-01

    Full Text Available The experimental modal analysis is often used to validate the accuracy of dynamic numerical models. It is also a good tool to obtain valuable information about current condition of the structures that could help to determine residual lifetime. The quality of modal testing results is highly dependent on the proper estimation of the natural frequencies from the frequency response function. This article presents the experimental modal test of the laboratory steel structure in which the natural frequencies and mode shapes are determined.

  13. Summary of key directives governing permanent disposal in a geologic repository

    International Nuclear Information System (INIS)

    Sands, S.C. III.

    1993-11-01

    This document was developed in support of the Idaho National Engineering Laboratory (INEL) Spent Fuel and Waste Management Technology Development Program (SF ampersand WMTDP). It is largely comprised of flow diagrams summarizing the key regulatory requirements which govern permanent disposal in a geologic repository. The key purposes are (1) to provide an easy and effective tool for referencing or cross referencing federal directives (i.e., regulations and orders), (2) to provide a method for examining the requirements in one directive category against the requirements in another, and (3) to list actions that must be taken to ensure directive compliance. The document is categorically broken down into a Transportation section and a Mined Geologic Disposal System (MGDS) section to ensure that the interrelationship of the entire disposal system is considered. The Transportation section describes the transportation packaging requirements, testing methods, and safety requirements imposed on fissile material shipments. The MGDS section encompasses technical aspects involved in siting, licensing, waste interaction with the container, container design features, physical characteristics of the surrounding environment, facility design features, barrier systems, safety features, criticality considerations, migration restrictions, implementation guidelines, and so forth. For purposes of illustration, the worst case scenario is outlined. It is important that the approaches and considerations contained in this document be integrated into the efforts of the SF ampersand WMTDP so that every applicable aspect of the regulatory requirements can be evaluated to avoid investing large sums of money into projects that do not take into account all of the aspects of permanent waste disposal. Not until an overall picture and clear understanding of these regulations is established can a basis be developed to govern the direction of future activities of the SF ampersand WMTDP

  14. Mounted Smartphones as Measurement and Control Platforms for Motor-Based Laboratory Test-Beds

    OpenAIRE

    Jared A. Frank; Anthony Brill; Vikram Kapila

    2016-01-01

    Laboratory education in science and engineering often entails the use of test-beds equipped with costly peripherals for sensing, acquisition, storage, processing, and control of physical behavior. However, costly peripherals are no longer necessary to obtain precise measurements and achieve stable feedback control of test-beds. With smartphones performing diverse sensing and processing tasks, this study examines the feasibility of mounting smartphones directly to test-beds to exploit their em...

  15. An Alternative Approach to Assessing Laboratory and Field Notebooks: The Data Retrieval Test

    Science.gov (United States)

    Bedford, Hilary; Bedford, Alan; Thomas, Judith; Ashton, Paul

    2010-01-01

    Marking field and laboratory notebooks can be a time consuming and tedious task. This article describes a system whereby the contents of student's notebooks are assessed by testing the students on what they have included and their understanding of what has been done. It also tests the quality of the student's notes--detailed, organised notes…

  16. Standard practice for conducting and evaluating laboratory corrosions tests in soils

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This practice covers procedures for conducting laboratory corrosion tests in soils to evaluate the corrosive attack on engineering materials. 1.2 This practice covers specimen selection and preparation, test environments, and evaluation of test results. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  17. Worldwide proficiency test for X ray fluorescence laboratories PTXRFIAEA/05 determination of minor and trace elements in marine sediment

    International Nuclear Information System (INIS)

    2009-01-01

    The proficiency test (code PTXRFIAEA05) was the fifth worldwide exercise organized by the IAEA Seibersdorf Laboratories in order to assist X ray fluorescence laboratories in assessment and improvement of their analytical performance. The test was carried out within the IAEA Project 1.4.3.4 (D.3.03) on Nuclear Spectrometry for Analytical Applications, under the Nuclear Science Programme. The main objective of the project was to enhance capability of interested Member States in effective utilization of nuclear spectrometries and analytical services in industry, human health, agriculture, and in monitoring and evaluation of environmental pollution. Marine sediment test samples with established homogeneity and well characterized known target values of the mass fractions of analytes were distributed to participating laboratories. The laboratories were requested to analyze the sample using established techniques following their analytical procedures. Based on the results of the proficiency test presented in the report each participating laboratory should assess its analytical performance results by using the specified criteria and, if appropriate, to identify discrepancies, and to correct relevant analytical procedures. The next proficiency test exercise will be executed in 2009

  18. Optimal Design Solutions for Permanent Magnet Synchronous Machines

    Directory of Open Access Journals (Sweden)

    POPESCU, M.

    2011-11-01

    Full Text Available This paper presents optimal design solutions for reducing the cogging torque of permanent magnets synchronous machines. A first solution proposed in the paper consists in using closed stator slots that determines a nearly isotropic magnetic structure of the stator core, reducing the mutual attraction between permanent magnets and the slotted armature. To avoid complications in the windings manufacture technology the stator slots are closed using wedges made of soft magnetic composite materials. The second solution consists in properly choosing the combination of pole number and stator slots number that typically leads to a winding with fractional number of slots/pole/phase. The proposed measures for cogging torque reduction are analyzed by means of 2D/3D finite element models developed using the professional Flux software package. Numerical results are discussed and compared with experimental ones obtained by testing a PMSM prototype.

  19. Analytical performances of food microbiology laboratories - critical analysis of 7 years of proficiency testing results.

    Science.gov (United States)

    Abdel Massih, M; Planchon, V; Polet, M; Dierick, K; Mahillon, J

    2016-02-01

    Based on the results of 19 food microbiology proficiency testing (PT) schemes, this study aimed to assess the laboratory performances, to highlight the main sources of unsatisfactory analytical results and to suggest areas of improvement. The 2009-2015 results of REQUASUD and IPH PT, involving a total of 48 laboratories, were analysed. On average, the laboratories failed to detect or enumerate foodborne pathogens in 3·0% of the tests. Thanks to a close collaboration with the PT participants, the causes of outliers could be identified in 74% of the cases. The main causes of erroneous PT results were either pre-analytical (handling of the samples, timing of analysis), analytical (unsuitable methods, confusion of samples, errors in colony counting or confirmation) or postanalytical mistakes (calculation and encoding of results). PT schemes are a privileged observation post to highlight analytical problems, which would otherwise remain unnoticed. In this perspective, this comprehensive study of PT results provides insight into the sources of systematic errors encountered during the analyses. This study draws the attention of the laboratories to the main causes of analytical errors and suggests practical solutions to avoid them, in an educational purpose. The observations support the hypothesis that regular participation to PT, when followed by feed-back and appropriate corrective actions, can play a key role in quality improvement and provide more confidence in the laboratory testing results. © 2015 The Society for Applied Microbiology.

  20. Cylindrical Hall Thrusters with Permanent Magnets

    International Nuclear Information System (INIS)

    Raitses, Yevgeny; Merino, Enrique; Fisch, Nathaniel J.

    2010-01-01

    The use of permanent magnets instead of electromagnet coils for low power Hall thrusters can offer a significant reduction of both the total electric power consumption and the thruster mass. Two permanent magnet versions of the miniaturized cylindrical Hall thruster (CHT) of different overall dimensions were operated in the power range of 50W-300 W. The discharge and plasma plume measurements revealed that the CHT thrusters with permanent magnets and electromagnet coils operate rather differently. In particular, the angular ion current density distribution from the permanent magnet thrusters has an unusual halo shape, with a majority of high energy ions flowing at large angles with respect to the thruster centerline. Differences in the magnetic field topology outside the thruster channel and in the vicinity of the channel exit are likely responsible for the differences in the plume characteristics measured for the CHTs with electromagnets and permanent magnets. It is shown that the presence of the reversing-direction or cusp-type magnetic field configuration inside the thruster channel without a strong axial magnetic field outside the thruster channel does not lead to the halo plasma plume from the CHT.

  1. Macroscopic simulation of isotropic permanent magnets

    International Nuclear Information System (INIS)

    Bruckner, Florian; Abert, Claas; Vogler, Christoph; Heinrichs, Frank; Satz, Armin; Ausserlechner, Udo; Binder, Gernot; Koeck, Helmut; Suess, Dieter

    2016-01-01

    Accurate simulations of isotropic permanent magnets require to take the magnetization process into account and consider the anisotropic, nonlinear, and hysteretic material behaviour near the saturation configuration. An efficient method for the solution of the magnetostatic Maxwell equations including the description of isotropic permanent magnets is presented. The algorithm can easily be implemented on top of existing finite element methods and does not require a full characterization of the hysteresis of the magnetic material. Strayfield measurements of an isotropic permanent magnet and simulation results are in good agreement and highlight the importance of a proper description of the isotropic material. - Highlights: • Simulations of isotropic permanent magnets. • Accurate calculation of remanence magnetization and strayfield. • Comparison with strayfield measurements and anisotropic magnet simulations. • Efficient 3D FEM–BEM coupling for solution of Maxwell equations.

  2. Present status of mechanical testing technology at the Research Hot Laboratory

    International Nuclear Information System (INIS)

    Kizaki, M.; Tobita, T.; Koya, T.; Kikuchi, T.

    1993-01-01

    Mechanical tests of irradiated metallic materials at the Research Hot Laboratory(RHL) have been carried out for 30 years to support material research in JAERI and to evaluate the irradiation integrity of pressure vessel steel in commercial power plant. Two tensile testing machines and one Charpy impact testing machine are available for the examinations. One of the tensile testing machines has 1000 kgf load capacity under the vacuum of ∼ 10 -7 torr at the temperature of 1300degC max.. The other one has 10 tonf load capacity, and is utilized for the multi-purpose tests such as tensile and compressive tests in air atmosphere at the temperature between -160 and 900degC. Examinations cover tensile test, bending test, J ic fracture toughness test, low cycle fatigue test and so on. Charpy impact testing machine with notched-bar specimen is instrumented with 30 kgf-m capacity in the temperature range of -140 - 240 degC. To support these mechanical tests in RHL, special jigs, devices and instruments have been developed. (author)

  3. Developing a competency framework for U.S. state food and feed testing laboratory personnel.

    Science.gov (United States)

    Kaml, Craig; Weiss, Christopher C; Dezendorf, Paul; Ishida, Maria; Rice, Daniel H; Klein, Ron; Salfinger, Yvonne

    2014-01-01

    A competency-based training curriculum framework for U.S. state food and feed testing laboratories personnel is being developed by the International Food Protection Training Institute (IFPTI) and three partners. The framework will help laboratories catalog existing training courses/modules, identify training gaps, inform training curricula, and create career-spanning professional development learning paths, ensuring consistent performance expectations and increasing confidence in shared test results. Ultimately, the framework will aid laboratories in meeting the requirements of ISO/IEC 17025 (2005) international accreditation and the U.S. Food Safety Modernization Act (U.S. Public Law 111-353). In collaboration with the Association of Food and Drug Officials, the Association of Public Health Laboratories, and the Association of American Feed Control Officials, IFPTI is carrying out the project in two phases. In 2013, an expert panel of seven subject matter experts developed competency and curriculum frameworks for five professional levels (entry, mid-level, expert, supervisor/manager, and senior administration) across four competency domains (technical, communication, programmatic, and leadership) including approximately 80 competencies. In 2014 the expert panel will elicit feedback from peers and finalize the framework.

  4. FJ44 Turbofan Engine Test at NASA Glenn Research Center's Aero-Acoustic Propulsion Laboratory

    Science.gov (United States)

    Lauer, Joel T.; McAllister, Joseph; Loew, Raymond A.; Sutliff, Daniel L.; Harley, Thomas C.

    2009-01-01

    A Williams International FJ44-3A 3000-lb thrust class turbofan engine was tested in the NASA Glenn Research Center s Aero-Acoustic Propulsion Laboratory. This report presents the test set-up and documents the test conditions. Farfield directivity, in-duct unsteady pressures, duct mode data, and phased-array data were taken and are reported separately.

  5. An inter- laboratory proficiency testing exercise for rabies diagnosis in Latin America and the Caribbean.

    Directory of Open Access Journals (Sweden)

    Alfonso Clavijo

    2017-04-01

    Full Text Available The direct fluorescent antibody test (DFA, is performed in all rabies reference laboratories across Latin America and the Caribbean (LAC. Despite DFA being a critical capacity in the control of rabies, there is not a standardized protocol in the region. We describe the results of the first inter-laboratory proficiency exercise of national rabies laboratories in LAC countries as part of the regional efforts towards dog-maintained rabies elimination in the American region. Twenty three laboratories affiliated to the Ministries of Health and Ministries of Agriculture participated in this exercise. In addition, the laboratories completed an online questionnaire to assess laboratory practices. Answers to the online questionnaire indicated large variability in the laboratories throughput, equipment used, protocols availability, quality control standards and biosafety requirements. Our results will inform actions to improve and harmonize laboratory rabies capacities across LAC in support for the regional efforts towards elimination of dog-maintained rabies.

  6. Reactor safety review of permanent changes

    International Nuclear Information System (INIS)

    Lam, K.F.

    1997-01-01

    Operational compliance engineers review all changes as part of a change control process. Each change, permanent or temporary, is required to undergo an intricate review process to ensure that the benefits associated with the change outweigh the risk. For permanent changes, it is necessary to ensure that the proposed design meets the nuclear safety requirements, conforms to the licensing requirements and complies with regulatory requirements. In addition, during installation of the permanent change and prior to in-service, a configuration management process is in place to align the change with operating and maintenance documents. (author)

  7. Permanent multipole magnets with adjustable strength

    International Nuclear Information System (INIS)

    Halbach, K.

    1983-01-01

    Preceded by a short discussion of the motives for using permanent magnets in accelerators, a new type of permanent magnet for use in accelerators is presented. The basic design and most important properties of a quadrople will be described that uses both steel and permanent magnet material. The field gradient produced by this magnet can be adjusted without changing any other aspect of the field produced by this quadrupole. The generalization of this concept to produce other multipole fields, or combination of multipole fields, will also be presented

  8. Nanocrystalline permanent magnets with enhanced properties

    International Nuclear Information System (INIS)

    Leonowicz, M.

    2002-01-01

    Parameters of permanent magnets result from the combination of intrinsic properties such as saturation magnetization, magnetic exchange, and magnetocrystalline energy, as well as microstructural parameters such as phase structure, grain size, and orientation. Reduction of grain size into nanocrystalline regime (∼ 50 nm) leads to the enhanced remanence which derives from ferromagnetic exchange coupling between highly refined grains. In this study the fundamental phenomena, quantities, and structure parameters, which define nanophase permanent magnets are presented and discussed. The theoretical considerations are confronted with experimental data for nanocrystalline Sm-Fe-N type permanent magnets. (author)

  9. Permanent multipole magnets with adjustable strength

    International Nuclear Information System (INIS)

    Halbach, K.

    1983-03-01

    Preceded by a short discussion of the motives for using permanent magnets in accelerators, a new type of permanent magnet for use in accelerators is presented. The basic design and most important properties of a quadrupole will be described that uses both steel and permanent magnet material. The field gradient produced by this magnet can be adjusted without changing any other aspect of the field produced by this quadrupole. The generalization of this concept to produce other multipole fields, or combination of multipole fields, will also be presented

  10. Errors in clinical laboratories or errors in laboratory medicine?

    Science.gov (United States)

    Plebani, Mario

    2006-01-01

    Laboratory testing is a highly complex process and, although laboratory services are relatively safe, they are not as safe as they could or should be. Clinical laboratories have long focused their attention on quality control methods and quality assessment programs dealing with analytical aspects of testing. However, a growing body of evidence accumulated in recent decades demonstrates that quality in clinical laboratories cannot be assured by merely focusing on purely analytical aspects. The more recent surveys on errors in laboratory medicine conclude that in the delivery of laboratory testing, mistakes occur more frequently before (pre-analytical) and after (post-analytical) the test has been performed. Most errors are due to pre-analytical factors (46-68.2% of total errors), while a high error rate (18.5-47% of total errors) has also been found in the post-analytical phase. Errors due to analytical problems have been significantly reduced over time, but there is evidence that, particularly for immunoassays, interference may have a serious impact on patients. A description of the most frequent and risky pre-, intra- and post-analytical errors and advice on practical steps for measuring and reducing the risk of errors is therefore given in the present paper. Many mistakes in the Total Testing Process are called "laboratory errors", although these may be due to poor communication, action taken by others involved in the testing process (e.g., physicians, nurses and phlebotomists), or poorly designed processes, all of which are beyond the laboratory's control. Likewise, there is evidence that laboratory information is only partially utilized. A recent document from the International Organization for Standardization (ISO) recommends a new, broader definition of the term "laboratory error" and a classification of errors according to different criteria. In a modern approach to total quality, centered on patients' needs and satisfaction, the risk of errors and mistakes

  11. Tested Studies for Laboratory Teaching. Proceedings of the Workshop/Conference of the Association for Biology Laboratory Education (ABLE) (13th, Laramie, Wyoming, June 11-15, 1991). Volume 13.

    Science.gov (United States)

    Goldman, Corey A., Ed.

    The focus of the Association for Biology Laboratory Education (ABLE) is to improve the undergraduate biology laboratory experience by promoting the development and dissemination of interesting, innovative, and reliable laboratory exercises. This proceedings volume contains 10 papers: "Testing Issues of Foraging and Flocking Behavior" (C. C.…

  12. Influence of Temperature Upon Permanent Deformation Parameters of Asphalt Concrete Mixes

    Directory of Open Access Journals (Sweden)

    Amjad Hamad Albayati

    2017-07-01

    Full Text Available The performance of asphalt concrete pavement has affected by many factors, the temperature is the most important environmental one which has a large effect on the structural behavior of flexible pavement materials. The main cause of premature failure of pavement is the rutting, Due to the viscoelastic nature of the asphalt cement, rutting is more pronounced in hot climate areas because the viscosity of the asphalt binder which is inversely related to rutting is significantly reduced with the increase in temperature resulting in a more rut susceptible paving mixtures. The objective of this study is to determine the effect of temperatures variations on the permanent deformation parameters (permanent strain (p, intercept (a, slope (b, Alpha and Mu as well as resilient strain (r and resilient modulus (Mr. To achieve this objective, one aggregate gradation with 12.5mm nominal maximum size, two grades of asphalt cements (40-50 and 60-70 brought form Al- Daurah refinery, limestone dust filler has been used to prepare the asphalt concrete mixtures. 30 Marshall specimens were prepared to determine the optimum asphalt cement content. Thereafter, 30 cylindrical asphalt concrete specimens (102mm in diameter and 203 mm in height are prepared in optimum asphalt cement and optimum ±0.5 percent. The prepared specimens were used in uniaxial repeated load test to evaluate the permanent deformation parameters of asphalt concrete mixes under the following testing temperature (5, 15, 25, 40 and 60c. The test result analyses appeared that Mr is decrease 51 percent when temperature increased from 5 c to 25 c and then decrease 22 percent with further increase in temperature from 25 c to 60 c. Also, the Alpha value decreases by a factor of 1.25 and 1.13 when temperature increases from 5 c to 25 c and 25 c to 60 c, espectively. Finally, statistical models were developed to predict the Alpha and Mu parameters of permanent deformation.

  13. Search behavior in various breeds of adult dogs (Canis familiaris): object permanence and olfactory cues.

    Science.gov (United States)

    Gagnon, S; Doré, F Y

    1992-03-01

    Human analog tests of object permanence were administered to various breeds of adult dogs (Canis familiaris). Experiment 1 showed that the performance of terriers, sporting, and working dogs did not differ. Dogs succeeded in solving invisible displacement problems, but performance was lower than in visible displacement tests. Familiarity with the task had some influence because invisible displacement tests were more successful if they were preceded by visible displacement tests. In Experiment 2, odor cues from the target object and the hiding screens were available or were masked. Results confirmed that success was lower in invisible than in visible displacement tests and that these problems were solved on the basis of representation of visual information rather than on the basis of olfactory cues or of local rule learning. Dogs are compared with other species that display Stage 6 object permanence.

  14. 21 CFR 212.60 - What requirements apply to the laboratories where I test components, in-process materials, and...

    Science.gov (United States)

    2010-04-01

    ... maintenance. Each laboratory must have and follow written procedures to ensure that equipment is routinely... 21 Food and Drugs 4 2010-04-01 2010-04-01 false What requirements apply to the laboratories where...) Laboratory Controls § 212.60 What requirements apply to the laboratories where I test components, in-process...

  15. A survey of methods used for antimicrobial susceptibility testing in veterinary diagnostic laboratories in the United States.

    Science.gov (United States)

    Dargatz, David A; Erdman, Matthew M; Harris, Beth

    2017-09-01

    Antimicrobial resistance is a serious threat to animal and human health worldwide, requiring a collaborative, holistic approach. The U.S. Government has developed a national strategy to address antimicrobial resistance, with one component being to monitor antimicrobial resistance in agricultural settings. We developed a survey to collect information about antimicrobial susceptibility testing (AST) from the veterinary diagnostic laboratory community in the United States, assessing current practices and technologies and determining how AST information is shared. Of the 132 surveys administered, 52 (39%) were returned. Overall, responding laboratories conducted susceptibility tests on 98,788 bacterial isolates in 2014, with Escherichia coli being the most common pathogen tested across all animal species. The 2 most common AST methods employed were the disk diffusion method (71%) and the Sensititre platform broth microdilution system (59%). Laboratories primarily used the Clinical Laboratory Standards Institute (CLSI) VET-01 standard (69%) and the automatically calculated interpretations provided by the commercial AST systems (61%) for interpreting their AST data. Only 22% of laboratories published AST data on a periodic basis, usually via annual reports published on the laboratory's website or through peer-reviewed journals for specific pathogens. Our results confirm that disk diffusion and broth microdilution remain the standard AST methods employed by U.S. veterinary diagnostic laboratories, and that CLSI standards are commonly used for interpreting AST results. This information will help determine the most efficient standardized methodology for future surveillance. Furthermore, the current infrastructure within laboratories, once harmonized, will help provide a mechanism for conducting national surveillance programs.

  16. 46 CFR 159.007-3 - Production inspections and tests: Independent laboratory's procedures.

    Science.gov (United States)

    2010-10-01

    ...'s procedures. 159.007-3 Section 159.007-3 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL APPROVAL OF EQUIPMENT AND... meets the inspection and test procedures of the laboratory; and (3) Are accepted by the Commandant under...

  17. Introduction to permanent magnets

    International Nuclear Information System (INIS)

    Zijlstra, H.

    1985-01-01

    Some general considerations concerning the application of permanent magnets are developed. The relevant magnet properties are discussed, with particular reference to Nd-Fe-B alloy. The author comes to the following conclusions; the air gap field B should be high, for high electrical efficiency; the magnet should face the air gap, for efficient use of the magnet material; the magnet material should therefore have a high remanence; and the new Nd-Fe-B magnet fits in nicely, having (potentially) the highest remanence ever reported in permanent magnets, combined with sufficient coercivity to sustain it

  18. Quality management and accreditation in a mixed research and clinical hair testing analytical laboratory setting-a review.

    Science.gov (United States)

    Fulga, Netta

    2013-06-01

    Quality management and accreditation in the analytical laboratory setting are developing rapidly and becoming the standard worldwide. Quality management refers to all the activities used by organizations to ensure product or service consistency. Accreditation is a formal recognition by an authoritative regulatory body that a laboratory is competent to perform examinations and report results. The Motherisk Drug Testing Laboratory is licensed to operate at the Hospital for Sick Children in Toronto, Ontario. The laboratory performs toxicology tests of hair and meconium samples for research and clinical purposes. Most of the samples are involved in a chain of custody cases. Establishing a quality management system and achieving accreditation became mandatory by legislation for all Ontario clinical laboratories since 2003. The Ontario Laboratory Accreditation program is based on International Organization for Standardization 15189-Medical laboratories-Particular requirements for quality and competence, an international standard that has been adopted as a national standard in Canada. The implementation of a quality management system involves management commitment, planning and staff education, documentation of the system, validation of processes, and assessment against the requirements. The maintenance of a quality management system requires control and monitoring of the entire laboratory path of workflow. The process of transformation of a research/clinical laboratory into an accredited laboratory, and the benefits of maintaining an effective quality management system, are presented in this article.

  19. FAMILIARISATION AND RELIABILITY OF SPRINT TEST INDICES DURING LABORATORY AND FIELD ASSESSMENT

    Directory of Open Access Journals (Sweden)

    Andrew Galbraith

    2009-12-01

    Full Text Available The aim of the study was to assess the reliability of sprint performance in both field and laboratory conditions. Twenty-one male (mean ± s: 19 ± 1 years, 1.79 ± 0.07 m, 77.6 ± 7.1 kg and seventeen female team sport players (mean ± s: 21 ± 4 years, 1.68 ± 0. 07 m, 62.7 ± 4.7 kg performed a maximal 20-metre sprint running test on eight separate occasions. Four trials were conducted on a non-motorised treadmill in the laboratory; the other four were conducted outdoors on a hard-court training surface with time recorded by single-beam photocells. Trials were conducted in random order with no familiarisation prior to testing. There was a significant difference between times recorded during outdoor field trials (OFT and indoor laboratory trials (ILT using a non-motorised treadmill (3.47 ± 0.53 vs. 6.06 ±1.17s; p < 0.001. The coefficient of variation (CV for time was 2.55-4.22% for OFT and 5.1-7.2% for ILT. During ILT peak force (420.9 ± 87.7N, mean force (147.2 ± 24.7N, peak power (1376.8 ± 451.9W and mean power (514.8 ± 164.4W, and were measured. The CV for all ILT variables was highest during trial 1-2 comparison. The CV (95% confidence interval for the trial 3-4 comparison yielded: 9.4% (7.7-12. 1%, 7.9% (6.4-10.2%, 10.1% (8.2-13.1% and 6.2% (5.1-8.0% for PF, MF, PP and MP and respectively. The results indicate that reliable data can be derived for single maximal sprint measures, using fixed distance protocols. However, significant differences in time/speed over 20-m exist between field and laboratory conditions. This is primarily due to the frictional resistance in the non- motorised treadmill. Measures of force and power during ILT require at least 3 familiarisations to reduce variability in test scores

  20. Improving laboratory efficiencies to scale-up HIV viral load testing.

    Science.gov (United States)

    Alemnji, George; Onyebujoh, Philip; Nkengasong, John N

    2017-03-01

    Viral load measurement is a key indicator that determines patients' response to treatment and risk for disease progression. Efforts are ongoing in different countries to scale-up access to viral load testing to meet the Joint United Nations Programme on HIV and AIDS target of achieving 90% viral suppression among HIV-infected patients receiving antiretroviral therapy. However, the impact of these initiatives may be challenged by increased inefficiencies along the viral load testing spectrum. This will translate to increased costs and ineffectiveness of scale-up approaches. This review describes different parameters that could be addressed across the viral load testing spectrum aimed at improving efficiencies and utilizing test results for patient management. Though progress is being made in some countries to scale-up viral load, many others still face numerous challenges that may affect scale-up efficiencies: weak demand creation, ineffective supply chain management systems; poor specimen referral systems; inadequate data and quality management systems; and weak laboratory-clinical interface leading to diminished uptake of test results. In scaling up access to viral load testing, there should be a renewed focus to address efficiencies across the entire spectrum, including factors related to access, uptake, and impact of test results.

  1. Influence of relief on permanent preservation areas.

    Science.gov (United States)

    Dos Santos, Alexandre Rosa; Chimalli, Tessa; Peluzio, João Batista Esteves; da Silva, Aderbal Gomes; Dos Santos, Gleissy Mary Amaral Dino Alves; Lorenzon, Alexandre Simões; Teixeira, Thaisa Ribeiro; de Castro, Nero Lemos Martins; Soares Ribeiro, Carlos Antonio Alvares

    2016-01-15

    Many countries have environmental legislation to protecting natural resources on private property. In Brazil, the Brazilian Forestry Code determines specific areas to maintain with natural vegetation cover, known as areas of permanent preservation (APP). Currently, there are few studies that relate topographic variables on APP. In this context, we sought to evaluate the influence of relief on the conservation of areas of permanent preservation (APP) in the areas surrounding Caparaó National Park, Brazil. By using the chi-squared statistical test, we verified that the presence of forest cover is closely associated with altitude. The classes of APP in better conservation status are slopes in addition to hilltops and mountains, whereas APP streams and springs are among the areas most affected by human activities. The most deforested areas are located at altitudes below 1100.00 m and on slopes less than 45°. All orientations of the sides were significant for APP conservation status, with the southern, southeastern, and southwestern sides showing the lower degrees of impact. The methodology can be adjusted to environmental legislation to other countries.

  2. Design and application of permanent magnet flux sources for mechanical testing of magnetoactive elastomers at variable field directions.

    Science.gov (United States)

    Hiptmair, F; Major, Z; Haßlacher, R; Hild, S

    2015-08-01

    Magnetoactive elastomers (MAEs) are a class of smart materials whose mechanical properties can be rapidly and reversibly changed by an external magnetic field. Due to this tunability, they are useable for actuators or in active vibration control applications. An extensive magnetomechanical characterization is necessary for MAE material development and requires experiments under cyclic loading in uniform but variable magnetic fields. MAE testing apparatus typically rely on fields of adjustable strength, but fixed (transverse) direction, often provided by electromagnets. In this work, two permanent magnet flux sources were developed as an add-on for a modular test stand, to allow for mechanical testing in uniform fields of variable direction. MAE specimens, based on a silicone matrix with isotropic and anisotropic carbonyl iron particle distributions, were subjected to dynamic mechanical analysis under different field and loading configurations. The magneto-induced increase of stiffness and energy dissipation was determined by the change of the hysteresis loop area and dynamic modulus values. A distinct influence of the composite microstructure and the loading state was observed. Due to the very soft and flexible matrix used for preparing the MAE samples, the material stiffness and damping behavior could be varied over a wide range via the applied field direction and intensity.

  3. Stress-strain relation of bentonite at undrained shear. Laboratory tests to investigate the influence of material composition and test technique

    Energy Technology Data Exchange (ETDEWEB)

    Dueck, Ann; Boergesson, Lennart; Johannesson, Lars-Erik (Clay Technology AB, Lund (Sweden))

    2010-12-15

    This report describes a laboratory study conducted to update the material model of the buffer material used in the analyses of the effect of a rock shear through a deposition hole. The study considers some new conditions and is especially focused on the reference case with MX-80Ca developed for SR-Site (MX-80 ion exchanged to Ca). The material model is based on relations between density, swelling pressure, shear strength and rate of strain. The reference model is described by Boergesson et al. (2010). The laboratory study is focused on undrained stress-strain-strength properties, which have been studied mainly by conducting triaxial tests and unconfined compression tests. The test results are compared to the earlier measurements and models which show that the new results fit very well into the general picture and models. For the new conditions suitable values of constants included in the model are proposed

  4. Stress-strain relation of bentonite at undrained shear. Laboratory tests to investigate the influence of material composition and test technique

    International Nuclear Information System (INIS)

    Dueck, Ann; Boergesson, Lennart; Johannesson, Lars-Erik

    2010-12-01

    This report describes a laboratory study conducted to update the material model of the buffer material used in the analyses of the effect of a rock shear through a deposition hole. The study considers some new conditions and is especially focused on the reference case with MX-80Ca developed for SR-Site (MX-80 ion exchanged to Ca). The material model is based on relations between density, swelling pressure, shear strength and rate of strain. The reference model is described by Boergesson et al. (2010). The laboratory study is focused on undrained stress-strain-strength properties, which have been studied mainly by conducting triaxial tests and unconfined compression tests. The test results are compared to the earlier measurements and models which show that the new results fit very well into the general picture and models. For the new conditions suitable values of constants included in the model are proposed

  5. The actual problems of the standardization of magnetically hard materials and permanent magnets

    International Nuclear Information System (INIS)

    Kurbatov, P.A.; Podolskiy, I.D.

    1998-01-01

    The standardization of industrial products raises their accordance with functional purpose, contributes to technological developments and the elimination of technical barriers in trade. The progress of the world trade necessitates the certification of permanent magnets and their manufacturing methods. According to ISO/IEC recommendations, the certification standards should contain the clear requirements to operation parameters of products, that can be impartially controlled. The testing procedures should be clearly formulated and assure that the results may be reproduced. This calls for creation of a system of interconnected certification standards: the standard for technical characteristics of prospective commercial magnetically hard materials, the standard specifications for permanent magnets, the standards for typical testing procedures and the standards for metrological assurance of measurements. (orig.)

  6. Permanent education

    International Nuclear Information System (INIS)

    Gardien, S.; Kirsch, R.

    1998-01-01

    The permanent education of the IPN-Lyon inscribes itself completely in the priorities of the tri-annual plan of education of CNRS. These priorities contribute to evolution of research, evaluation of the professions, integration during the professional carriers of the personnel and form the frame for new management practice implementation

  7. Permanent Housing for Child Welfare-Involved Families: Impact on Child Maltreatment Overview.

    Science.gov (United States)

    Fowler, Patrick J; Schoeny, Michael

    2017-09-01

    A longitudinal randomized controlled trial tested whether access to permanent housing reduces child maltreatment among inadequately housed families under investigation for child abuse and neglect. The study followed homeless and child welfare-involved families randomly assigned to receive a referral for housing subsidies plus housing case management (n = 75, 196 children) or housing case management alone (n = 75, 186 children). Latent growth models examined change in caregiver-reported frequencies of psychological aggression, physical abuse, and neglect toward children at five time points across 2.5 years. Intent-to-treat analyses suggested treatment differences for minor assault and neglect that approached significance; families randomly assigned to permanent housing plus case management exhibited marginally greater declines compared to families referred for housing case management only. Caregiver psychological aggression remained high over time, regardless of treatment condition. No evidence indicated higher risk families benefitted more from permanent housing. Results show some promise of permanent housing and highlight the complex needs of homeless families under investigation for child maltreatment. Findings emphasize the importance of continued involvement from the child welfare system to connect families with important resources. © Society for Community Research and Action 2017.

  8. Transient or permanent fisheye views

    DEFF Research Database (Denmark)

    Jakobsen, Mikkel Rønne; Hornbæk, Kasper

    2012-01-01

    Transient use of information visualization may support specific tasks without permanently changing the user interface. Transient visualizations provide immediate and transient use of information visualization close to and in the context of the user’s focus of attention. Little is known, however......, about the benefits and limitations of transient visualizations. We describe an experiment that compares the usability of a fisheye view that participants could call up temporarily, a permanent fisheye view, and a linear view: all interfaces gave access to source code in the editor of a widespread...... programming environment. Fourteen participants performed varied tasks involving navigation and understanding of source code. Participants used the three interfaces for between four and six hours in all. Time and accuracy measures were inconclusive, but subjective data showed a preference for the permanent...

  9. Bioassay Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Bioassay Laboratory is an accredited laboratory capable of conducting standardized and innovative environmental testing in the area of aquatic ecotoxicology. The...

  10. In-situ magnetization of NdFeB magnets for permanent magnet machines

    International Nuclear Information System (INIS)

    Chang, L.; Eastham, T.R.; Dawson, G.E.

    1991-01-01

    In-situ magnetizers are needed to facilitate the assembly of permanent magnet machines and to remagnetize the magnets after weakening due to a fault condition. The air-core magnetizer in association with the silicon steel lamination structure of the rotor has advantages over its iron-core counterpart. This novel method has been used to magnetize the NdFeB magnets in a 30-hp permanent magnet synchronous motor. The magnetizing capability for different magnetizer geometries was investigated for the magnetization of NdFeB material. The design, testing, and operation of this magnetizer are reported in this paper

  11. Permanent molars: Delayed development and eruption

    Directory of Open Access Journals (Sweden)

    Arathi R

    2006-05-01

    Full Text Available Delayed development and eruption of all the permanent molars is a rare phenomenon, which can cause disturbance in the developing occlusion. The eruption of permanent first and second molars is very important for the coordination of facial growth and for providing sufficient occlusal support for undisturbed mastication. In the case described, the first permanent molars were delayed in their development and were seen erupting at the age of nine and a half years. Severe disparity between the left and the right side of the dentition with respect to the rate of development of molars were also present.

  12. Organization of Proficiency Testing for Dairy Laboratories in Croatia, Bosnia and Herzegovina and Macedonia in Order to Improve Quality Assurance

    Directory of Open Access Journals (Sweden)

    Nataša Mikulec

    2009-06-01

    Full Text Available Participation in proficiency testing is not only an obligation for all analytical laboratories which tend to be credible, but also an opportunity to check how the results agree with the reference or assign value. The Reference Laboratory for Milk and Dairy Products of the Dairy Science Department, Faculty of Agriculture University of Zagreb, is itself incorporated in the proficiency testing organized by dairy laboratories from Germany, Italy, France, Switzerland and Slovenia. The aim is to find out its own accuracy and reliability in particular milk and dairy products analyses. On the basis of seven years experience of participating in proficiency testing, five years ago the Reference Laboratory started organizing its own proficiency testing for dairy laboratories in Croatia, Bosnia and Herzegovina and Macedonia for milk components such as milk fat, protein, lactose and somatic cells count. The results of the analyses have been statistically analyzed and, on the basis of Z-score, the successful measurements have been estimated. The aim of this paper is to demonstrate the organisation and data processing of proficiency testing for milk fat, protein, lactose and somatic cells count in milk for the involved dairy laboratories.

  13. Individual differences in object permanence performance at 8 months: locomotor experience and brain electrical activity.

    Science.gov (United States)

    Bell, M A; Fox, N A

    1997-12-01

    This work was designed to investigate individual differences in hands-and-knees crawling and frontal brain electrical activity with respect to object permanence performance in 76 eight-month-old infants. Four groups of infants (one prelocomotor and 3 with varying lengths of hands-and-knees crawling experience) were tested on an object permanence scale in a research design similar to that used by Kermoian and Campos (1988). In addition, baseline EEG was recorded and used as an indicator of brain development, as in the Bell and Fox (1992) longitudinal study. Individual differences in frontal and occipital EEG power and in locomotor experience were associated with performance on the object permanence task. Infants successful at A-not-B exhibited greater frontal EEG power and greater occipital EEG power than unsuccessful infants. In contrast to Kermoian and Campos (1988), who noted that long-term crawling experience was associated with higher performance on an object permanence scale, infants in this study with any amount of hands and knees crawling experience performed at a higher level on the object permanence scale than prelocomotor infants. There was no interaction among brain electrical activity, locomotor experience, and object permanence performance. These data highlight the value of electrophysiological research and the need for a brain-behavior model of object permanence performance that incorporates both electrophysiological and behavioral factors.

  14. Object permanence in marine mammals using the violation of expectation procedure.

    Science.gov (United States)

    Singer, Rebecca; Henderson, Elizabeth

    2015-03-01

    Object permanence refers to the ability to process information about objects even when they are not visible. One stage of object permanence, called visible displacement, involves being able to find an object that has been fully hidden from view. Visible displacement has been demonstrated in many animal species, yet very little is known about object permanence in marine mammals. In addition, the methodology for testing visible displacement has sometimes been called into question because alternative explanations could account for subjects' success. The current study investigated visible displacement in Atlantic bottlenose dolphins and California sea lions using a methodology called violation of expectation, in which the animal's fish bucket was placed on a table surrounded on three sides by curtains. A solid screen placed in front of the bucket was then rotated in an arc from front to back. The screen was rotated either 120° (possible event) or 180° (surprising event), appearing as if the bucket disappeared. Both dolphins and sea lions looked significantly longer during the 180°, unexpected, trials than the expected event trials. Results suggest that both dolphins and sea lions pass visible displacement tests without the use of perceptual cues. This article is part of a Special Issue entitled: Tribute to Tom Zentall. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Using fee-for-service testing to generate revenue for the 21st century public health laboratory.

    Science.gov (United States)

    Loring, Carol; Neil, R Brock; Gillim-Ross, Laura; Bashore, Matthew; Shah, Sandip

    2013-01-01

    The decrease in appropriations for state public health laboratories (SPHLs) has become a major concern as tax revenues and, subsequently, state and federal funding, have decreased. These reductions have forced SPHLs to pursue revenue-generating opportunities to support their work. We describe the current state of funding in a sampling of SPHLs and the challenges these laboratories face as they implement or expand fee-for-service testing. We conducted surveys of SPHLs to collect data concerning laboratory funding sources, test menus, fee-for-service testing, and challenges to implementing fee-for-service testing. Most SPHLS receive funding through three revenue sources: state appropriation, federal funding, and fee-for-service testing (cash funds). Among SPHLs, state appropriations ranged from $0 to more than $6 per capita, federal funding ranged from $0.10 to $5 per capita, and revenue from fee-for-service testing ranged from $0 to $4 per capita. The tests commonly performed on a fee-for-service basis included assays for sexually transmitted diseases, mycobacterial cultures, newborn screening, and water testing. We found that restrictive legislation, staffing shortages, inadequate software for billing fee-for-service testing, and regulations on how SPHLs use their generated revenue are impediments to implementing fee-for-service testing. Some SPHLs are considering implementing or expanding fee-for-service testing as a way to recapture funds lost as a result of state and federal budget cuts. This analysis revealed many of the obstacles to implementing fee-for-service testing in SPHLs and the potential impact on SPHLs of continued decreases in funding.

  16. Community Laboratory Testing for Cryptosporidium: Multicenter Study Retesting Public Health Surveillance Stool Samples Positive for Cryptosporidium by Rapid Cartridge Assay with Direct Fluorescent Antibody Testing.

    Directory of Open Access Journals (Sweden)

    Dawn M Roellig

    Full Text Available Cryptosporidium is a common cause of sporadic diarrheal disease and outbreaks in the United States. Increasingly, immunochromatography-based rapid cartridge assays (RCAs are providing community laboratories with a quick cryptosporidiosis diagnostic method. In the current study, the Centers for Disease Control and Prevention (CDC, the Association of Public Health Laboratories (APHL, and four state health departments evaluated RCA-positive samples obtained during routine Cryptosporidium testing. All samples underwent "head to head" re-testing using both RCA and direct fluorescence assay (DFA. Community level results from three sites indicated that 54.4% (166/305 of Meridian ImmunoCard STAT! positives and 87.0% (67/77 of Remel Xpect positives were confirmed by DFA. When samples were retested by RCA at state laboratories and compared with DFA, 83.3% (155/186 of Meridian ImmunoCard STAT! positives and 95.2% (60/63 of Remel Xpect positives were confirmed. The percentage of confirmed community results varied by site: Minnesota, 39.0%; New York, 63.9%; and Wisconsin, 72.1%. The percentage of confirmed community results decreased with patient age; 12.5% of community positive tests could be confirmed by DFA for patients 60 years of age or older. The percentage of confirmed results did not differ significantly by sex, storage temperature, time between sample collection and testing, or season. Findings from this study demonstrate a lower confirmation rate of community RCA positives when compared to RCA positives identified at state laboratories. Elucidating the causes of decreased test performance in order to improve overall community laboratory performance of these tests is critical for understanding the epidemiology of cryptosporidiosis in the United States (US.

  17. Superconducting permanent magnets

    International Nuclear Information System (INIS)

    Wipf, S.L.; Laquer, H.L.

    1989-01-01

    The concept of superconducting permanent magnets with fields trapped in shells or cylinders of Type II superconductors is an old one. Unfortunately, the low values of 0.5 to 1T for the first flux jump field, which is independent of the actual current density, have frustrated its implementation with classical Type II superconductors. The fact that the flux jump fields for high temperature superconductors should be an order of magnitude larger at liquid nitrogen temperatures allows us to reconsider these options. Analysis of the hysteresis patterns, based on the critical state model, shows that, if the dimensions are chosen so that the sample is penetrated at a field B/sub p/, which is equal to or just less than the first flux jump field, B/sub fj/, a temporarily applied field of 2B/sub fj/ will trap 0.5 B/sub fj/. Thus for a 90 K superconductor with a B/sub fj/ of 6T, a permanent field of 3 T should be trapped, with an energy product of 1.8 MJ/m/sup 3/ (225 MG . Oe). This is five times as large as for the best permanent magnet materials. The authors discuss means to verify the analysis and the limitations imposed by the low critical current densities in presently available high temperature superconductors

  18. Radiation Testing at Sandia National Laboratories: Sandia – JPL Collaboration for Europa Lander

    Energy Technology Data Exchange (ETDEWEB)

    Hattar, Khalid Mikhiel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Ion Beam Lab.; Olszewska-Wasiolek, Maryla Aleksandra [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Gamma Irradiation Facility

    2017-01-01

    Sandia National Laboratories (SNL) is assisting Jet Propulsion Laboratory in undertaking feasibility studies and performance assessments for the Planetary Protection aspect of the Europa Lander mission. The specific areas of interest for this project are described by task number. This white paper presents the evaluation results for Task 2, Radiation Testing, which was stated as follows: Survey SNL facilities and capabilities for simulating the Europan radiation environment and assess suitability for: A. Testing batteries, electronics, and other component and subsystems B. Exposing biological organisms to assess their survivability metrics. The radiation environment the Europa Lander will encounter on route and in orbit upon arrival at its destination consists primarily of charged particles, energetic protons and electrons with the energies up to 1 GeV. The charged particle environments can be simulated using the accelerators at the Ion Beam Laboratory. The Gamma Irradiation Facility and its annex, the Low Dose Rate Irradiation Facility, offer irradiations using Co-60 gamma sources (1.17 and 1.33 MeV), as well as Cs-137 gamma (0.661 MeV) AmBe neutron (0-10 MeV) sources.

  19. How Reliable Is Laboratory Testing?

    Science.gov (United States)

    ... type of container and mixed with the right preservative, when appropriate. The laboratory staff who collect samples ... avoid known interferences. You may be instructed to fast or avoid certain foods or activities. Carefully follow these instructions to prepare ...

  20. Acoustic testing and modeling: an advanced undergraduate laboratory.

    Science.gov (United States)

    Russell, Daniel A; Ludwigsen, Daniel O

    2012-03-01

    This paper describes an advanced laboratory course in acoustics, specifically targeted for students with an interest in engineering applications at a school with a strongly integrated industrial co-op program. The laboratory course is developed around a three-pronged approach to problem solving that combines and integrates theoretical models, computational models, and experimental data. The course is structured around modules that begin with fundamental concepts and build laboratory skills and expand the knowledge base toward a final project. Students keep a detailed laboratory notebook, write research papers in teams, and must pass laboratory certification exams. This paper describes the course layout and philosophy and shares personal experience from both faculty and student perspectives. © 2012 Acoustical Society of America

  1. Results of single borehole hydraulic tests in the Mizunami Underground Research Laboratory project. FY 2012 - FY 2015

    International Nuclear Information System (INIS)

    Onoe, Hironori; Takeuchi, Ryuji

    2016-11-01

    This report summarize the results of the single borehole hydraulic tests of 151 sections carried out at the -300 m Stage and the -500 m Stage of the Mizunami Underground Research Laboratory from FY 2012 to FY 2015. The details of each test (test interval depth, geology, etc.) as well as the interpreted hydraulic parameters and analytical methods used are presented in this report. Furthermore, the previous results of the single borehole hydraulic tests carried out in the Regional Hydrogeological Study Project and the Mizunami Underground Research Laboratory Project before FY 2012 are also summarized in this report. (author)

  2. Measurements of vacuum magnetic birefringence using permanent dipole magnets: the PVLAS experiment

    Science.gov (United States)

    Della Valle, F.; Gastaldi, U.; Messineo, G.; Milotti, E.; Pengo, R.; Piemontese, L.; Ruoso, G.; Zavattini, G.

    2013-05-01

    The PVLAS collaboration is presently assembling a new apparatus (at the INFN section of Ferrara, Italy) to detect vacuum magnetic birefringence (VMB). VMB is related to the structure of the quantum electrodynamics (QED) vacuum and is predicted by the Euler-Heisenberg-Weisskopf effective Lagrangian. It can be detected by measuring the ellipticity acquired by a linearly polarized light beam propagating through a strong magnetic field. Using the very same optical technique it is also possible to search for hypothetical low-mass particles interacting with two photons, such as axion-like (ALP) or millicharged particles. Here we report the results of a scaled-down test setup and describe the new PVLAS apparatus. This latter is in construction and is based on a high-sensitivity ellipsometer with a high-finesse Fabry-Perot cavity (>4 × 105) and two 0.8 m long 2.5 T rotating permanent dipole magnets. Measurements with the test setup have improved, by a factor 2, the previous upper bound on the parameter Ae, which determines the strength of the nonlinear terms in the QED Lagrangian: A(PVLAS)e < 3.3 × 10-21 T-2 at 95% c.l. Furthermore, new laboratory limits have been put on the inverse coupling constant of ALPs to two photons and confirmation of previous limits on the fractional charge of millicharged particles is given.

  3. Interventions to Improve Follow-Up of Laboratory Test Results Pending at Discharge: A Systematic Review.

    Science.gov (United States)

    Whitehead, Nedra S; Williams, Laurina; Meleth, Sreelatha; Kennedy, Sara; Epner, Paul; Singh, Hardeep; Wooldridge, Kathleene; Dalal, Anuj K; Walz, Stacy E; Lorey, Tom; Graber, Mark L

    2018-02-28

    Failure to follow up test results pending at discharge (TPAD) from hospitals or emergency departments is a major patient safety concern. The purpose of this review is to systematically evaluate the effectiveness of interventions to improve follow-up of laboratory TPAD. We conducted literature searches in PubMed, CINAHL, Cochrane, and EMBASE using search terms for relevant health care settings, transition of patient care, laboratory tests, communication, and pending or missed tests. We solicited unpublished studies from the clinical laboratory community and excluded articles that did not address transitions between settings, did not include an intervention, or were not related to laboratory TPAD. We also excluded letters, editorials, commentaries, abstracts, case reports, and case series. Of the 9,592 abstracts retrieved, 8 met the inclusion criteria and reported the successful communication of TPAD. A team member abstracted predetermined data elements from each study, and a senior scientist reviewed the abstraction. Two experienced reviewers independently appraised the quality of each study using published LMBP™ A-6 scoring criteria. We assessed the body of evidence using the A-6 methodology, and the evidence suggested that electronic tools or one-on-one education increased documentation of pending tests in discharge summaries. We also found that automated notifications improved awareness of TPAD. The interventions were supported by suggestive evidence; this type of evidence is below the level of evidence required for LMBP™ recommendations. We encourage additional research into the impact of these interventions on key processes and health outcomes. © 2018 Society of Hospital Medicine.

  4. Tests for oil/dispersant toxicity: In situ laboratory assays

    International Nuclear Information System (INIS)

    Wright, D.A.; Coelho, G.M.; Aurand, D.V.

    1995-01-01

    As part of its readiness program in oil spill response, the Marine Pollution Control Unit (MPCU), Department of Transport, U.K. conducts annual field trials in the North Sea, approximately 30 nautical miles from the southeast coast of England. The trials take the form of controlled releases of crude oil or Medium Fuel/Gas Oil mix (MFO), with and without the application of Corexit 9527 dispersant. In 1994 and 1995 the authors conducted a series of in situ toxicity bioassays in association with these spills with included 48h LC50 tests for turbot (Scophthalmus maximus) and oyster (Crassostrea gigas) larvae, a 48 h oyster (C. gigas) embryonic development test and two full life-cycle assays using the copepods Acartia tonsa and Tisbe battagliai. Tests were also conducted in the Chesapeake Bay laboratory using estuarine species including the copepod Eurytemora affinis and the inland silverside Menidia beryllina. Here, the authors report on the results of these assays, together with 1996 in situ toxicity data resulting from Norwegian field trials in the northern North Sea

  5. Characterization of the ELIMED prototype permanent magnet quadrupole system

    Science.gov (United States)

    Russo, A. D.; Schillaci, F.; Pommarel, L.; Romano, F.; Amato, A.; Amico, A. G.; Calanna, A.; Cirrone, G. A. P.; Costa, M.; Cuttone, G.; Amato, C.; De Luca, G.; Flacco, F. A.; Gallo, G.; Giove, D.; Grmek, A.; La Rosa, G.; Leanza, R.; Maggiore, M.; Malka, V.; Milluzzo, G.; Petringa, G.; Pipek, J.; Scuderi, V.; Vauzour, B.; Zappalà, E.

    2017-01-01

    The system described in this work is meant to be a prototype of a more performing one that will be installed at ELI-Beamlines in Prague for the collection of ions produced after the interaction Laser-target, [1]. It has been realized by the researchers of INFN-LNS (Laboratori Nazionali del Sud of the Instituto Nazionale di Fisica Nucleare) and SIGMAPHI, a French company, using a system of Permanent Magnet Quadrupoles (PMQs), [2]. The final system that will be installed in Prague is designed for protons and carbons up to 60 MeV/u, around 10 times more than the energies involved in the present work. The prototype, shown in this work, has been tested in collaboration with the SAPHIR experimental facility group at LOA (Laboratoire d'Optique Appliqueé) in Paris using a 200 TW Ti:Sapphire laser system. The purpose of this work is to validate the design and the performances of this large and compact bore system and to characterize the beam produced after the interaction laser-target and its features. Moreover, the optics simulations have been compared with a real beam shape on a GAFChromic film. The procedure used during the experimental campaign and the most relevant results are reported here demonstrating a good agreement with the simulations and a good control on the beam optics.

  6. Characterization of the ELIMED prototype permanent magnet quadrupole system

    International Nuclear Information System (INIS)

    Russo, A.D.; Schillaci, F.; Romano, F.; Amato, A.; Amico, A.G.; Calanna, A.; Cirrone, G.A.P.; Costa, M.; Cuttone, G.; Amato, C.; Luca, G. De; Gallo, G.; Grmek, A.; Rosa, G. La; Leanza, R.; Pommarel, L.; Flacco, F.A.; Malka, V.; Giove, D.; Maggiore, M.

    2017-01-01

    The system described in this work is meant to be a prototype of a more performing one that will be installed at ELI-Beamlines in Prague for the collection of ions produced after the interaction Laser-target, [1]. It has been realized by the researchers of INFN-LNS (Laboratori Nazionali del Sud of the Instituto Nazionale di Fisica Nucleare) and SIGMAPHI, a French company, using a system of Permanent Magnet Quadrupoles (PMQs), [2]. The final system that will be installed in Prague is designed for protons and carbons up to 60 MeV/u, around 10 times more than the energies involved in the present work. The prototype, shown in this work, has been tested in collaboration with the SAPHIR experimental facility group at LOA (Laboratoire d'Optique Appliqueé) in Paris using a 200 TW Ti:Sapphire laser system. The purpose of this work is to validate the design and the performances of this large and compact bore system and to characterize the beam produced after the interaction laser-target and its features. Moreover, the optics simulations have been compared with a real beam shape on a GAFChromic film. The procedure used during the experimental campaign and the most relevant results are reported here demonstrating a good agreement with the simulations and a good control on the beam optics.

  7. Emergency Response Proficiency Test for Japanese Laboratories: Determination of Selected Radionuclides in Water, Soil, Vegetation and Aerosol Filters

    International Nuclear Information System (INIS)

    2013-01-01

    Reliable determination of natural and artificial radionuclides in environmental samples is necessary for compliance with radiation protection and environmental regulations. The IAEA assists Member State laboratories in maintaining and improving their readiness in this regard by producing reference materials, by developing standardized analytical methods, and by conducting interlaboratory comparisons and proficiency tests as tools for quality control. To fulfil this obligation and ensure a reliable, rapid and consistent worldwide response, the IAEA Terrestrial Environment Laboratory in Seibersdorf, Austria, organizes interlaboratory comparisons and proficiency tests. In addition, the IAEA coordinates the worldwide network of Analytical Laboratories for the Measurement of Environmental Radioactivity (ALMERA). After the accident at the Fukushima Daiichi nuclear power plant in March 2011, Japan requested the IAEA to organize an emergency response proficiency test for Japanese laboratories with the aim of assessing their capacity to rapidly and accurately measure radionuclides in environmental samples. The IAEA responded to the request by assembling a special sample set covering the main environmental samples and radionuclides of interest in the case of a nuclear emergency situation. Water, soil, vegetation and aerosol filter samples were made available to Japanese laboratories for analysis by gamma ray spectrometry. This report presents the results of the IAEA-TEL-2011-08 emergency response proficiency test for Japanese laboratories on the determination of selected radionuclides in water, soil, vegetation and aerosol filters. The report includes descriptions of the methodologies and data evaluation approach used, as well as summary evaluations of each radionuclide and individual evaluation reports of each laboratory. This proficiency test was designed to identify analytical problems and to support Member State laboratories in their efforts to improve the quality of

  8. The development of permanent isolation barriers for buried wastes in cool deserts: Hanford, Washington

    International Nuclear Information System (INIS)

    Link, S.O.; Gee, G.W.; Wing, N.R.

    1993-12-01

    The purpose of this report is to present the results of research on surface hydrology and the role of plants and animals on permanent isolation barrier effectiveness at Hanford. These topics are a subset of a larger set of studies on permanent isolation barriers. A complete review of these tasks has been documented. We also discuss current work that tests our integrated scientific and engineering concepts on a large prototype barrier to determine if it can isolate buried wastes from environmental dispersion

  9. Laboratory Evaluation of In Situ Chemical Oxidation for Groundwater Remediation, Test Area North, Operable Unit 1-07B, Idaho National Engineering and Environmental Laboratory, Volume Three - Appendix F

    Energy Technology Data Exchange (ETDEWEB)

    Cline, S.R.; Denton, D.L.; Giaquinto, J.M.; McCracken, M.K.; Starr, R.C.

    1999-04-01

    This appendix supports the results and discussion of the laboratory work performed to evaluate the feasibility of in situ chemical oxidation for Idaho National Environmental and Engineering Laboratory's (INEEL) Test Area North (TAN) which is contained in ORNL/TM-13711/V1. This volume contains Appendix F. Appendix F is essentially a photocopy of the ORNL researchers' laboratory notebooks from the Environmental Sciences Division (ESD) and the Radioactive Materials Analytical Laboratory (RMAL).

  10. Performance Comparison between a Permanent Magnet Synchronous Motor and an Induction Motor as a Traction Motor for High Speed Train

    Science.gov (United States)

    Kondo, Minoru; Kawamura, Junya; Terauchi, Nobuo

    Performance tests are carried out to demonstrate the superiority of a permanent magnet synchronous motor to an induction motor as a traction motor for high-speed train. A prototype motor was manufactured by replacing the rotor of a conventional induction motor. The test results show that the permanent magnet motor is lighter, efficient and more silent than the induction motor because of the different rotor structure.

  11. Advantages and limitations of anticipating laboratory test results from regression- and tree-based rules derived from electronic health-record data.

    Directory of Open Access Journals (Sweden)

    Fahim Mohammad

    Full Text Available Laboratory testing is the single highest-volume medical activity, making it useful to ask how well one can anticipate whether a given test result will be high, low, or within the reference interval ("normal". We analyzed 10 years of electronic health records--a total of 69.4 million blood tests--to see how well standard rule-mining techniques can anticipate test results based on patient age and gender, recent diagnoses, and recent laboratory test results. We evaluated rules according to their positive and negative predictive value (PPV and NPV and area under the receiver-operator characteristic curve (ROC AUCs. Using a stringent cutoff of PPV and/or NPV≥0.95, standard techniques yield few rules for sendout tests but several for in-house tests, mostly for repeat laboratory tests that are part of the complete blood count and basic metabolic panel. Most rules were clinically and pathophysiologically plausible, and several seemed clinically useful for informing pre-test probability of a given result. But overall, rules were unlikely to be able to function as a general substitute for actually ordering a test. Improving laboratory utilization will likely require different input data and/or alternative methods.

  12. Advantages and limitations of anticipating laboratory test results from regression- and tree-based rules derived from electronic health-record data.

    Science.gov (United States)

    Mohammad, Fahim; Theisen-Toupal, Jesse C; Arnaout, Ramy

    2014-01-01

    Laboratory testing is the single highest-volume medical activity, making it useful to ask how well one can anticipate whether a given test result will be high, low, or within the reference interval ("normal"). We analyzed 10 years of electronic health records--a total of 69.4 million blood tests--to see how well standard rule-mining techniques can anticipate test results based on patient age and gender, recent diagnoses, and recent laboratory test results. We evaluated rules according to their positive and negative predictive value (PPV and NPV) and area under the receiver-operator characteristic curve (ROC AUCs). Using a stringent cutoff of PPV and/or NPV≥0.95, standard techniques yield few rules for sendout tests but several for in-house tests, mostly for repeat laboratory tests that are part of the complete blood count and basic metabolic panel. Most rules were clinically and pathophysiologically plausible, and several seemed clinically useful for informing pre-test probability of a given result. But overall, rules were unlikely to be able to function as a general substitute for actually ordering a test. Improving laboratory utilization will likely require different input data and/or alternative methods.

  13. Lawful Permanent Residents Fiscal Year 2011 Country

    Data.gov (United States)

    Department of Homeland Security — Lawful permanet residents (LPRs) are foreign nationals who have been gratned the right to reside permanently in the United States. LPRs are also known as 'permanent...

  14. Characteristics of permanent deformation rate of warm mix asphalt with additives variation (BNA-R and zeolite)

    Science.gov (United States)

    Wahjuningsih, Nurul; Hadiwardoyo, Sigit Pranowo; Sumabrata, R. Jachrizal

    2017-06-01

    Permanent deformation is one of the criteria of failure on asphalt concrete mixture. The nature of the bitumen melt at high temperatures, this condition causes the asphalt concrete mixture tends to soften due to an increase in temperature of the road surface. The increase in surface temperature and the load wheel that has repeated itself on the same trajectory causes deformation groove has formed. Conditions rutting due to permanent deformation has resulted in inconvenience to the passengers and can lead to high costs of road maintenance. On the road planning process required a prediction of the rate of the permanent deformation of asphalt concrete mixtures. It is important to know early on the road surface damage due to vehicle load and surface temperature during service life. Asphalt has been mixed with the additive BNA-R and Zeolite intended to make variations in the characteristics of bitumen in this study. This variation is further combined with variations in the composition of aggregate in order to obtain a combination of asphalt-aggregate mixture. This mixture using warm mix, and to determine the permanent deformation of asphalt mix with material combinations was performed through the wheel tracking test machine with 3,780 cycles or 7,560 tracks for 3 hours. Another analysis to determine the characteristics of asphalt concrete mixtures have also been carried out changes in the surface temperature at the time of the test track. From the results of the test track to nearly 8 thousand passes has seen permanent deformation characteristics of asphalt concrete mixture with a variation of the characteristics of bitumen and aggregate variation. Groove of deformation due to a wheel load from the initial until the last passes shows that there are influence of compaction temperature on the variation of bitumen and aggregate composition to the relationship of permanent deformation of the wheel groove, especially on the road surface temperature changes.

  15. Public Service Motivation Differences BetweenPermanent and Contract Employees in the Local Government

    Directory of Open Access Journals (Sweden)

    Wayu Eko Yudiatmaja

    2017-12-01

    Full Text Available This article examines the distinction of public service motivation (PSM on street-level bureaucracy in Indonesia. Focus of this study is to review the differentiation of public service motivation between permanent and contract employees in sub-districts of Tanjungpinang, Kepulauan Riau. The dimensions and indicators of Perry’s (1996 measurement of PSM is used to analyze the differentiation of public service motivation between permanent and contract employees. Independent sampel t-test has employed to 129 government employees and 74 non-government employees in Tanjungpinang. Unlike in developed countries that PSM of its civil services are higher than PSM of contract employees, the findings of this research proves that there is no differences between PSM of permanent and contract employees. The findings of this research rejects the conclusion of foreign scholars suggesting the PSM construct was viable for internationally environment.

  16. Performance of IPEN/CNEN-SP Neutron Activation Analysis Laboratory for microelement determinations in proficiency testing

    International Nuclear Information System (INIS)

    Armelin, Maria Jose A.; Saiki, Mitiko; Souza, Gilberto B. de; Nogueira, Ana Rita A.

    2009-01-01

    The performance of Neutron Activation Laboratory, IPEN - CNEN/SP, was evaluated for the Ca, Fe, K, Mn, Na and Zn determinations in animal feed samples for ruminants through a proficiency test (PT) program. This PT program is organized by EMBRAPA Cattle Southeast to evaluate laboratories that analyze animal feed samples. Considering the fractions of satisfactory z-scores (%) of evaluated analytes to determine the laboratories performance, the general performance indicator obtained by IPEN - CNEN/SP ranged from 90 to 95% of the satisfactory results during the period of participation in the evaluation, four years. (author)

  17. Laboratory tests for diagnosis of food allergy: advantages, disadvantages and future perspectives.

    Science.gov (United States)

    Moneret-Vautrin, D A; Kanny, G; Frémont, S

    2003-04-01

    Numerous biological tests point to the diagnosis of food sensitization: detection of specific IgEs by Rast techniques, multi-detection assays, immunoblotting, screening of basophil activation (BAT or FAST), assays for leukotriene LTC4 release (CAST), measurement of plasma histamine, serum tryptase, serum ECP, urinary EDN, completed by mannitol-lactulose test evaluating intestinal permeability, assay of fecal IgEs, Rast for specific IgG4. Primary screening for anti-food IgEs by multi-detection assays seeks justification from insufficient clinical data and false positive tests are common in patients sensitized to pollens or latex, on account of in vitro cross reactivities (CR). Multiple CR explain positive Rast to vegetal food allergens in such patients. Biological tests should not be performed as the first line of diagnosis. In vivo sensitisation is assessed by positive prick-tests, demonstrating the bivalence of allergens, as well as the affinity of specific IgEs, two conditions necessary to bridge membrane bound specific IgEs, leading to the release of mediators. Prick-tests are closer to clinical symptoms than biological tests. However, the diagnosis of food allergy is based on standardised oral challenges. Exceptions are high levels of specific IgEs to egg (> 6 kUl/l), peanut (> 15 kUl/l), fish (> 20 kUl/l) and milk (> 32 kUl/l), reaching a 95% predictive positive value. Rast inhibition tests are useful to identify masked allergens in foods. Research developments will have impact on the development of new diagnostic tools: allergen mixes reinforcing a food extract by associated recombinant major allergens, multiple combination of recombinant allergens (chips) or tests with synthetic epitopes aimed a the prediction of recovery. Laboratory tests take place in the decision free for the diagnosis for the food allergy and the follow-up of the levels specific IgEs is a tool to assess outcome and contributes to predict recovery or persistent allergy. Up to now the

  18. Point of care testing of fecal calprotectin as a substitute for routine laboratory analysis

    DEFF Research Database (Denmark)

    Hejl, Julie; Theede, Klaus; Møllgren, Brian

    2018-01-01

    Objectives Fecal calprotectin (FC) is widely used to monitor the activity of inflammatory bowel disease (IBD) and to tailor medical treatment to disease activity. Laboratory testing of fecal samples may have a turnaround time of 1–2 weeks, whereas FC home testing allows results within hours...... and thus enables a rapid response to clinical deterioration. Design and methods Fifty-five stool samples were analyzed by the IBDoc® Calprotectin Home Testing kit and the BÜHLMANN fCAL® turbo assay on a Roche Cobas 6000 c501. The correlation between the assays was assessed using Spearman's Rho correlation...... coefficient and the intermediate imprecision of both assays was calculated. Results We found a strong correlation coefficient of 0.887 between FC measured on IBDoc® and the laboratory assay BÜHLMANN fCAL® turbo. The coefficients of variation (CVs) at three different FC levels were in the range 2...

  19. NNWSI waste form testing at Argonne National Laboratory

    International Nuclear Information System (INIS)

    Bates, J.K.; Gerding, T.J.; Abrajano, T.A. Jr.; Ebert, W.L.; Mazer, J.J.

    1988-11-01

    The Nevada Nuclear Waste Storage Investigation (NNWSI) Project is investigating the tuff beds of Yucca Mountain, Nevada, as a potential location for a high-level radioactive waste repository. As part of the waste package development portion of this project, experiments are being performed by the Chemical Technology Division of Argonne National Laboratory to study the behavior of the waste form under anticipated repository conditions. These experiments include the development and performance of a test to measure waste form behavior in unsaturated conditions and the performance of experiments designed to study the behavior of waste package components in an irradiated environment. Previous reports document developments in these areas through 1986. This report summarizes progress during the period January--June 1987, 19 refs., 17 figs., 20 tabs

  20. Sweat test for cystic fibrosis: Wearable sweat sensor vs. standard laboratory test.

    Science.gov (United States)

    Choi, Dong-Hoon; Thaxton, Abigail; Jeong, In Cheol; Kim, Kain; Sosnay, Patrick R; Cutting, Garry R; Searson, Peter C

    2018-03-23

    Sweat chloride testing for diagnosis of cystic fibrosis (CF) involves sweat induction, collection and handling, and measurement in an analytical lab. We have developed a wearable sensor with an integrated salt bridge for real-time measurement of sweat chloride concentration. Here, in a proof-of-concept study, we compare the performance of the sensor to current clinical practice in CF patients and healthy subjects. Sweat was induced on both forearms of 10 individuals with CF and 10 healthy subjects using pilocarpine iontophoresis. A Macroduct sweat collection device was attached to one arm and sweat was collected for 30 min and then sent for laboratory analysis. A sensor was attached to the other arm and the chloride ion concentration monitored in real time for 30 min using a Bluetooth transceiver and smart phone app. Stable sweat chloride measurements were obtained within 15 min following sweat induction using the wearable sensor. We define the detection time as the time at which the standard deviation of the real-time chloride ion concentration remained below 2 mEq/L for 5 min. The sweat volume for sensor measurements at the detection time was 13.1 ± 11.4 μL (SD), in many cases lower than the minimum sweat volume of 15 μL for conventional testing. The mean difference between sweat chloride concentrations measured by the sensor and the conventional laboratory practice was 6.2 ± 9.5 mEq/L (SD), close to the arm-to-arm variation of about 3 mEq/L. The Pearson correlation coefficient between the two measurements was 0.97 highlighting the excellent agreement between the two methods. A wearable sensor can be used to make real-time measurements of sweat chloride within 15 min following sweat induction, requiring a small sweat volume, and with excellent agreement to standard methods. Copyright © 2018 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.