WorldWideScience

Sample records for peripherally fused cyclopenta

  1. Bacterial and human cell mutagenicity study of some C[sub 18]H[sub 10] cyclopenta-fused polycyclic aromatic hydrocarbons associated with fossil fuels combustion

    Energy Technology Data Exchange (ETDEWEB)

    Lafleur, A.L.; Longwell, J.P.; Marr, J.A.; Monchamp, P.A.; Thilly, W.G. (Massachusetts Institute of Technology, Cambridge (United States)); Mulder, P.P.Y.; Boere, B.B.; Cornelisse, J.; Lugtenburg, J. (Univ. of Leiden (Netherlands))

    1993-06-01

    A number of isomeric C[sub 18]H[sub 10] polycyclic aromatic hydrocarbons (PAHs), thought to be primarily cyclopenta-fused PAHs, are produced during the combustion and pyrolysis of fossil fuels. To determine the importance of their contributions to the total mutagenic activity of combustion and pyrolysis samples in which they are found, we characterized reference quantities of four C[sub 18]H[sub 10] CP-PAHs: benzol [ghi] fluoranthene (BF), cyclopenta [cd] pyrene (CPP), cyclopent [hi] acephenanthrylene (CPAP), and cyclopent [hi] acaenthrylene (CPAA). Synthesis of CPAA and CPAP is described. The availability of reference samples of these isomers also proved to be an essential aid in the identification of the C[sub 18]H[sub 10] species often found in combustion and pyrolysis samples. Chemical analysis of selected combustion and pyrolysis samples showed that CPP was generally the most abundant C[sub 18]H[sub 10] isomer, followed by CPAP and BF. CPAA was detected only in pyrolysis products from pure PAHs. We tested the four C[sub 18]H[sub 10] PAHs for mutagenicity in a forward mutation assay using S. typhimurium. CPP, BF, and CPAA were roughly twice as mutagenic as benzo[a]pyrene (BaP), whereas CPAP was only slightly active. These PAHs were also tested for mutagenic activity in human cells. In this assay, CPP and CPAA were strongly mutagenic but less active than BaP, whereas CPAP and BF were inactive at the dose levels tested. Also, the bacterial and human cell mutagenicity of CPAA and CPAP were compared with the mutagenicity of their monocyclopenta-fused analogs, aceanthrylene and acephenanthrylene. Although the mutagenicities of CPAP and acephenanthrylene are similar, the mutagenic activity of CPAA is an order of magnitude greater than that of aceanthrylene.

  2. Study on the synthesis of the cyclopenta[f]indole core of raputindole A

    Directory of Open Access Journals (Sweden)

    Nils Marsch

    2016-02-01

    Full Text Available The raputindoles from the rutaceous tree Raputia simulans share a cyclopenta[f]indole partial structure the synthesis of which is subject of this investigation. An efficient route to a series of 1,5-di(indol-6-ylpentenones was developed via Mo/Au-catalyzed Meyer–Schuster rearrangement of tertiary propargylic alcohol precursors. However, none of the enones underwent the desired Nazarov cyclization to a cyclopenta[f]indole. More suitable were 6-hydroxyallylated indolines which gave good yields of cyclopenta[f]indolines after treatment with SnCl4, as soon as sterically demanding β-cyclocitral adducts were reacted. Most successful were Pt(II and Au(I-catalyzed cyclizations of N-TIPS-protected indolin-6-yl-substituted propargylacetates which provided the hydrogenated tricyclic cyclopenta[f]indole core system in high yield.

  3. Improved Photovoltaic Performance of a Semicrystalline Narrow Bandgap Copolymer Based on 4H-Cyclopenta[2,1-b : 3,4-b ']dithiophene Donor and Thiazolo[5,4-d]thiazole Acceptor Units

    NARCIS (Netherlands)

    Van Mierloo, Sarah; Hadipour, Afshin; Spijkman, Mark-Jan; Van den Brande, Niko; Ruttens, Bart; Kesters, Jurgen; D'Haen, Jan; Van Assche, Guy; de Leeuw, Dago M.; Aernouts, Tom; Manca, Jean; Lutsen, Laurence; Vanderzande, Dirk J.; Maes, Wouter; Haen, Jan D’

    2012-01-01

    A solution processable narrow bandgap polymer composed of alternating 2,5-dithienylthiazolo[5,4-d]thiazole and asymmetrically alkyl-substituted 4H-cyclopenta[2,1-b:3,4-b']dithiophene units (PCPDT-DTTzTz) was synthesized by Suzuki polycondensation and the donor acceptor copolymer was thoroughly

  4. Cyclopenta[b]naphthalene cyanoacrylate dyes: synthesis and evaluation as fluorescent molecular rotors.

    Science.gov (United States)

    Kocsis, Laura S; Elbel, Kristyna M; Hardigree, Billie A; Brummond, Kay M; Haidekker, Mark A; Theodorakis, Emmanuel A

    2015-03-14

    We describe the design, synthesis and fluorescent profile of a family of environment-sensitive dyes in which a dimethylamino (donor) group is conjugated to a cyanoacrylate (acceptor) unit via a cyclopenta[b]naphthalene ring system. This assembly satisfies the typical D-π-A motif of a fluorescent molecular rotor and exhibits solvatochromic and viscosity-sensitive fluorescence emission. The central naphthalene ring system of these dyes was synthesized via a novel intramolecular dehydrogenative dehydro-Diels-Alder (IDDDA) reaction that permits incorporation of the donor and acceptor groups in variable positions around the aromatic core. A bathochromic shift of excitation and emission peaks was observed with increasing solvent polarity but the dyes exhibited a complex emission pattern with a second red emission band when dissolved in nonpolar solvents. Consistent with other known molecular rotors, the emission intensity increased with increasing viscosity. Interestingly, closer spatial proximity between the donor and the acceptor groups led to decreased viscosity sensitivity combined with an increased quantum yield. This observation indicates that structural hindrance of intramolecular rotation dominates when the donor and acceptor groups are in close proximity. The examined compounds give insight into how excited state intramolecular rotation can be influenced by both the solvent and the chemical structure.

  5. About a New Type of Fuse Based on the Controllable Fusing Effect

    Directory of Open Access Journals (Sweden)

    PLESCA, A.

    2009-06-01

    Full Text Available Fuses are among the best known of electrical devices and there are an extremely large number in use throughout the world. Beside of the advantageous features, the nowadays fuses have certain drawbacks. Therefore, a new type of fuse based on controllable fusing concept is proposed and a study as regards the total clearing time is done. The new concept has been validated through many experimental tests at different current values. The new type of fuse based on controllable fusing concept can be integrated within an overcurrent protection system especially to protect power semiconductors where the Joule integral criterion is better satisfied.

  6. Investigations into the construction of the pentasubstituted ring C of Neosurugatoxin – a crystallographic study

    Directory of Open Access Journals (Sweden)

    Alan M. Jones

    2016-01-01

    Full Text Available The crystal structures of three cyclopenta[c]furans with various substituents at the 4-, 5- and 6-positions of the ring system are reported, namely, (±-(3aR,4S,5S,6aS-4-methyl-5-phenylhexahydro-1H-cyclopenta[c]furan-4,5-diol, C14H18O3, (I, (±-(3aR,4S,5S,6aS-4-benzyloxy-4-methyl-5-phenylhexahydro-1H-cyclopenta[c]furan-5-ol, C21H24O3, (II, and (±-(1aR,1bS,4aR,5S,5aR-5-benzyloxy-5-methyl-5a-phenylhexahydro-2H-oxireno[2′,3′:3,4]cyclopenta[1,2-c]furan, C21H22O3, (III. The dominant interaction in (I and (II is an O—H...O hydrogen bond across the bicyclic 5,5-ring system between the non-functionalized hydroxy group and the tetrahydrofuran O atom, which appears to influence the envelope conformations of the fused five-membered rings, whereas in (III, the rings have different conformations. A weak intramolecular C—H...O interaction appears to influence the degree of tilt of the phenyl ring attached to the 5-position and is different in (I compared to (II and (III.

  7. Dendritic cells fused with different pancreatic carcinoma cells induce different T-cell responses

    Directory of Open Access Journals (Sweden)

    Andoh Y

    2013-01-01

    Full Text Available Yoshiaki Andoh,1,2 Naohiko Makino,2 Mitsunori Yamakawa11Department of Pathological Diagnostics, 2Department of Gastroenterology, Yamagata University School of Medicine, Yamagata, JapanBackground: It is unclear whether there are any differences in the induction of cytotoxic T lymphocytes (CTL and CD4+CD25high regulatory T-cells (Tregs among dendritic cells (DCs fused with different pancreatic carcinomas. The aim of this study was to compare the ability to induce cytotoxicity by human DCs fused with different human pancreatic carcinoma cell lines and to elucidate the causes of variable cytotoxicity among cell lines.Methods: Monocyte-derived DCs, which were generated from peripheral blood mononuclear cells (PBMCs, were fused with carcinoma cells such as Panc-1, KP-1NL, QGP-1, and KP-3L. The induction of CTL and Tregs, and cytokine profile of PBMCs stimulated by fused DCs were evaluated.Results: The cytotoxicity against tumor targets induced by PBMCs cocultured with DCs fused with QGP-1 (DC/QGP-1 was very low, even though PBMCs cocultured with DCs fused with other cell lines induced significant cytotoxicity against the respective tumor target. The factors causing this low cytotoxicity were subsequently investigated. DC/QGP-1 induced a significant expansion of Tregs in cocultured PBMCs compared with DC/KP-3L. The level of interleukin-10 secreted in the supernatants of PBMCs cocultured with DC/QGP-1 was increased significantly compared with that in DC/KP-3L. Downregulation of major histocompatibility complex class I expression and increased secretion of vascular endothelial growth factor were observed with QGP-1, as well as in the other cell lines.Conclusion: The present study demonstrated that the cytotoxicity induced by DCs fused with pancreatic cancer cell lines was different between each cell line, and that the reduced cytotoxicity of DC/QGP-1 might be related to the increased secretion of interleukin-10 and the extensive induction of Tregs

  8. Dihydropyridine-fused and pyridine-fused coumarins: Reduction on a glassy carbon electrode in dimethylformamide

    International Nuclear Information System (INIS)

    Nuñez-Vergara, Luis J.; Pardo-Jiménez, V.; Barrientos, C.; Olea-Azar, C.A.; Navarrete-Encina, P.A.; Squella, J.A.

    2012-01-01

    In this study, two series of dihydropyridine-fused and pyridine-fused coumarins were synthesised and electrochemically characterised in aprotic medium. In both series, the most easily reducible groups were the endocyclic carbonyl groups. The electrochemical mechanism for both types of compounds is strongly dependent on the experimental time-scale. Cyclic voltammetric (CV) reduction on a glassy carbon electrode (GCE) of the endocyclic carbonyl group of dihydropyridine-fused coumarins involves an ECEC mechanism with two electron transfer steps that are coupled with chemical reactions to produce the corresponding hemiacetal derivative. In the case of pyridine-fused coumarins, CV reduction of the endocyclic carbonyl group involves an EEC mechanism. ESR studies revealed the presence of a stabilised intermediate only for the pyridine-fused derivatives. Our theoretical study showed a spin density map of radical species delocalised mainly within the coumarin ring, indicating the reduction of the endocyclic carbonyl group. In the case of the dihydropyridine-fused derivatives, the mildly acid hydrogen of the dihydropyridine ring destabilises the radical via a father–son type reaction.

  9. Comparative evaluation of fiber fuse models

    International Nuclear Information System (INIS)

    Davis, D.D.; Mettler, S.C.; DiGiovanni, D.J.

    1997-01-01

    A phenomenon which results in the catastrophic destruction of the guiding properties of an optical fiber has been observed at laser power densities on the order of 3 x 10 6 watts/cm 2 in the core. This phenomenon is characterized by the propagation of a bright visible light from the point of initiation toward the laser source. The term 'fiber fuse' has been used because of the similarity in appearance to a burning fuse. The fiber fuse has been shown to start when the end of the fiber is contacted. It has also been initiated spontaneously from mechanical splices. This paper reports experimental data gathered on the fiber fuse and discusses their relationship to proposed physical mechanisms

  10. Fused Bead Analysis of Diogenite Meteorites

    Science.gov (United States)

    Mittlefehldt, D.W.; Beck, B.W.; McSween, H.Y.; Lee, C.T. A.

    2009-01-01

    Bulk rock chemistry is an essential dataset in meteoritics and planetary science [1]. A common method used to obtain the bulk chemistry of meteorites is ICP-MS. While the accuracy, precision and low detection limits of this process are advantageous [2], the sample size used for analysis (approx.70 mg) can be a problem in a field where small and finite samples are the norm. Fused bead analysis is another bulk rock analytical technique that has been used in meteoritics [3]. This technique involves forming a glass bead from 10 mg of sample and measuring its chemistry using a defocused beam on a microprobe. Though the ICP-MS has lower detection limits than the microprobe, the fused bead method destroys a much smaller sample of the meteorite. Fused bead analysis was initially designed for samples with near-eutectic compositions and low viscosities. Melts generated of this type homogenize at relatively low temperatures and produce primary melts near the sample s bulk composition [3]. The application of fused bead analysis to samples with noneutectic melt compositions has not been validated. The purpose of this study is to test if fused bead analysis can accurately determine the bulk rock chemistry of non-eutectic melt composition meteorites. To determine this, we conduct two examinations of the fused bead. First, we compare ICP-MS and fused bead results of the same samples using statistical analysis. Secondly, we inspect the beads for the presence of crystals and chemical heterogeneity. The presence of either of these would indicate incomplete melting and quenching of the bead.

  11. Use of low fusing alloy in dentistry.

    Science.gov (United States)

    Wee, A G; Schneider, R L; Aquilino, S A

    1998-11-01

    Low fusing alloy has been used in dentistry for remount procedures in both fixed and removable prosthodontics, in implant prosthodontics for the fabrication of solid implant casts, in maxillofacial prosthetics as oral radiation shields, and in dental research for its unique properties. Previously, the use of low fusing alloy was thought to offer a high degree of dimensional accuracy. However, multiple in vitro studies have shown that its presumed dimensional accuracy may be questionable. This article reviews the physical properties, metallurgical considerations of low fusing alloy, its applications in dentistry, and a safe, simple method of using low fusing alloy.

  12. A Radiographic Study of Fused and Geminated Tooth

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chul Jae; Lee, Sang Rae [Dept. of Oral Radiology, College of Dentistry, Kyunhee University, Seoul (Korea, Republic of)

    1990-02-15

    The incidence and several characteristic features of fused and geminated teeth were studied radiographically, with full mouth periapical radiogram and pantomogram, in 4201 patients of mixed dentition and 5358 patients of permanent dentition. The obtained results were as follows: 1. The prevalence was revealed to 2.86%, 0.32%, 0.33%, and 0.06% in deciduous fused tooth, permanent fused tooth, deciduous geminated tooth and permanent geminated tooth respectively, and these anomalies were occurred in female more than male. 2. Fused teeth were observed predominantly in lower anterior teeth area, especially in lateral incisor and canine region, and many cases of deciduous geminated tooth were observed in upper central incisor region. 3. Congenital missing rates of succedaneous tooth in deciduous fused teeth were 57.1%, 85.7%, 71.0%, 69.0% in upper right and left central-lateral incisor regions, lower right and left lateral incisor-canine regions, respectively. 4. Prevalence of dental caries was 42.3%, 18.8% and 5.6% in deciduous fused, deciduous geminated and permanent fused tooth, respectively. 5. In classifying of fused and geminated teeth into 9 type, by following appearance such as number of crown, root, pulp chamber and pulp canal of those teeth, it was more favorable that Type I (2 crown, 2 root, 2 pulp chamber, 2 pulp canal) in deciduous fused tooth and Type IX (1 crown, 1 root, 1 pulp chamber, 1 pulp canal) in permanent used tooth, deciduous and permanent geminated tooth.

  13. A Radiographic Study of Fused and Geminated Tooth

    International Nuclear Information System (INIS)

    Park, Chul Jae; Lee, Sang Rae

    1990-01-01

    The incidence and several characteristic features of fused and geminated teeth were studied radiographically, with full mouth periapical radiogram and pantomogram, in 4201 patients of mixed dentition and 5358 patients of permanent dentition. The obtained results were as follows: 1. The prevalence was revealed to 2.86%, 0.32%, 0.33%, and 0.06% in deciduous fused tooth, permanent fused tooth, deciduous geminated tooth and permanent geminated tooth respectively, and these anomalies were occurred in female more than male. 2. Fused teeth were observed predominantly in lower anterior teeth area, especially in lateral incisor and canine region, and many cases of deciduous geminated tooth were observed in upper central incisor region. 3. Congenital missing rates of succedaneous tooth in deciduous fused teeth were 57.1%, 85.7%, 71.0%, 69.0% in upper right and left central-lateral incisor regions, lower right and left lateral incisor-canine regions, respectively. 4. Prevalence of dental caries was 42.3%, 18.8% and 5.6% in deciduous fused, deciduous geminated and permanent fused tooth, respectively. 5. In classifying of fused and geminated teeth into 9 type, by following appearance such as number of crown, root, pulp chamber and pulp canal of those teeth, it was more favorable that Type I (2 crown, 2 root, 2 pulp chamber, 2 pulp canal) in deciduous fused tooth and Type IX (1 crown, 1 root, 1 pulp chamber, 1 pulp canal) in permanent used tooth, deciduous and permanent geminated tooth.

  14. Additive manufacturing of transparent fused quartz

    Science.gov (United States)

    Luo, Junjie; Hostetler, John M.; Gilbert, Luke; Goldstein, Jonathan T.; Urbas, Augustine M.; Bristow, Douglas A.; Landers, Robert G.; Kinzel, Edward C.

    2018-04-01

    This paper investigates a filament-fed process for additive manufacturing (AM) of fused quartz. Glasses such as fused quartz have significant scientific and engineering applications, which include optics, communications, electronics, and hermetic seals. AM has several attractive benefits such as increased design freedom, faster prototyping, and lower processing costs for small production volumes. However, current research into glass AM has focused primarily on nonoptical applications. Fused quartz is studied here because of its desirability for use in high-quality optics due to its high transmissivity and thermal stability. Fused quartz filaments are fed into a CO2 laser-generated molten region, smoothly depositing material onto the workpiece. Spectroscopy and pyrometry are used to measure the thermal radiation incandescently emitted from the molten region. The effects of the laser power and scan speed are determined by measuring the morphology of single tracks. Thin walls are printed to study the effects of layer-to-layer height. This information is used to deposit solid pieces including a cylindrical-convex shape capable of focusing visible light. The transmittance and index homogeneity of the printed fused quartz are measured. These results show that the filament-fed process has the potential to print transmissive optics.

  15. An Imide-Based Pentacyclic Building Block for n-Type Organic Semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Fu-Peng [Soochow Univ., Suzhou (China). Inst. of Functional Nano & Soft Materials (FUNSOM); Un, Hio-Ieng [Peking Univ., Beijing (China). Beijing National Lab. for Molecular Sciences, Key Lab. of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, Key Lab. of Polymer Chemistry and Physics of Ministry of Education, Center for Soft Matter Science and Engineering, College of Chemistry and Molecular Engineering; Li, Yongxi [Soochow Univ., Suzhou (China). Inst. of Functional Nano & Soft Materials (FUNSOM); Hu, Hailiang [Soochow Univ., Suzhou (China). Inst. of Functional Nano & Soft Materials (FUNSOM); Yuan, Yi [Soochow Univ., Suzhou (China). Inst. of Functional Nano & Soft Materials (FUNSOM); Yang, Bin [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Center for Nanophase Materials Science (CNMS); Xiao, Kai [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Center for Nanophase Materials Science (CNMS); Chen, Wei [Argonne National Lab. (ANL), Lemont, IL (United States). Science Div.; Wang, Jie-Yu [Peking Univ., Beijing (China). Beijing National Lab. for Molecular Sciences, Key Lab. of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, Key Lab. of Polymer Chemistry and Physics of Ministry of Education, Center for Soft Matter Science and Engineering, College of Chemistry and Molecular Engineering; Jiang, Zuo-Quan [Soochow Univ., Suzhou (China). Inst. of Functional Nano & Soft Materials (FUNSOM); Pei, Jian [Peking Univ., Beijing (China). Beijing National Lab. for Molecular Sciences, Key Lab. of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, Key Lab. of Polymer Chemistry and Physics of Ministry of Education, Center for Soft Matter Science and Engineering, College of Chemistry and Molecular Engineering; Liao, Liang-Sheng [Soochow Univ., Suzhou (China). Inst. of Functional Nano & Soft Materials (FUNSOM)

    2017-10-09

    A new electron-deficient unit with fused 5-heterocyclic ring was developed by replacing a cyclopenta-1,3-diene from electron-rich donor indacenodithiophene (IDT) with cyclohepta- 4,6-diene-1,3-diimde unit. The imide bridging endows BBI with fixed planar configuration and both low the highest occupied molecular orbital (HOMO) and the lowest unoccupied molecular orbit (LUMO) energy levels. Organic field-effect transistors (OFETs) based on BBI polymers exhibit electron mobility up to 0.34 cm2 V-1 s-1, which indicates that the BBI is a promising ntype semiconductor for optoelectronics.

  16. Porphyrins Fused with Unactivated Polycyclic Aromatic Hydrocarbons

    KAUST Repository

    Diev, Vyacheslav V.; Schlenker, Cody W.; Hanson, Kenneth; Zhong, Qiwen; Zimmerman, Jeramy D.; Forrest, Stephen R.; Thompson, Mark E.

    2012-01-01

    A systematic study of the preparation of porphyrins with extended conjugation by meso,β-fusion with polycyclic aromatic hydrocarbons (PAHs) is reported. The meso-positions of 5,15-unsubstituted porphyrins were readily functionalized with PAHs. Ring fusion using standard Scholl reaction conditions (FeCl 3, dichloromethane) occurs for perylene-substituted porphyrins to give a porphyrin β,meso annulated with perylene rings (0.7:1 ratio of syn and anti isomers). The naphthalene, pyrene, and coronene derivatives do not react under Scholl conditions but are fused using thermal cyclodehydrogenation at high temperatures, giving mixtures of syn and anti isomers of the meso,β-fused porphyrins. For pyrenyl-substituted porphyrins, a thermal method gives synthetically acceptable yields (>30%). Absorption spectra of the fused porphyrins undergo a progressive bathochromic shift in a series of naphthyl (λ max = 730 nm), coronenyl (λ max = 780 nm), pyrenyl (λ max = 815 nm), and perylenyl (λ max = 900 nm) annulated porphyrins. Despite being conjugated with unsubstituted fused PAHs, the β,meso-fused porphyrins are more soluble and processable than the parent nonfused precursors. Pyrenyl-fused porphyrins exhibit strong fluorescence in the near-infrared (NIR) spectral region, with a progressive improvement in luminescent efficiency (up to 13% with λ max = 829 nm) with increasing degree of fusion. Fused pyrenyl-porphyrins have been used as broadband absorption donor materials in photovoltaic cells, leading to devices that show comparatively high photovoltaic efficiencies. © 2011 American Chemical Society.

  17. Porphyrins Fused with Unactivated Polycyclic Aromatic Hydrocarbons

    KAUST Repository

    Diev, Vyacheslav V.

    2012-01-06

    A systematic study of the preparation of porphyrins with extended conjugation by meso,β-fusion with polycyclic aromatic hydrocarbons (PAHs) is reported. The meso-positions of 5,15-unsubstituted porphyrins were readily functionalized with PAHs. Ring fusion using standard Scholl reaction conditions (FeCl 3, dichloromethane) occurs for perylene-substituted porphyrins to give a porphyrin β,meso annulated with perylene rings (0.7:1 ratio of syn and anti isomers). The naphthalene, pyrene, and coronene derivatives do not react under Scholl conditions but are fused using thermal cyclodehydrogenation at high temperatures, giving mixtures of syn and anti isomers of the meso,β-fused porphyrins. For pyrenyl-substituted porphyrins, a thermal method gives synthetically acceptable yields (>30%). Absorption spectra of the fused porphyrins undergo a progressive bathochromic shift in a series of naphthyl (λ max = 730 nm), coronenyl (λ max = 780 nm), pyrenyl (λ max = 815 nm), and perylenyl (λ max = 900 nm) annulated porphyrins. Despite being conjugated with unsubstituted fused PAHs, the β,meso-fused porphyrins are more soluble and processable than the parent nonfused precursors. Pyrenyl-fused porphyrins exhibit strong fluorescence in the near-infrared (NIR) spectral region, with a progressive improvement in luminescent efficiency (up to 13% with λ max = 829 nm) with increasing degree of fusion. Fused pyrenyl-porphyrins have been used as broadband absorption donor materials in photovoltaic cells, leading to devices that show comparatively high photovoltaic efficiencies. © 2011 American Chemical Society.

  18. SINA: A test system for proximity fuses

    Science.gov (United States)

    Ruizenaar, M. G. A.

    1989-04-01

    SINA, a signal generator that can be used for testing proximity fuses, is described. The circuitry of proximity fuses is presented; the output signal of the RF circuit results from a mixing of the emitted signal and received signal that is Doppler shifted in frequency by the relative motion of the fuse with respect to the reflecting target of surface. With SINA, digitized and stored target and clutter signals (previously measured) can be transformed to Doppler signals, for example during a real flight. SINA can be used for testing fuse circuitry, for example in the verification of results of computer simulations of the low frequency Doppler signal processing. The software of SINA and its use are explained.

  19. 30 CFR 57.12036 - Fuse removal or replacement.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fuse removal or replacement. 57.12036 Section 57.12036 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Electricity Surface and Underground § 57.12036 Fuse removal or replacement. Fuses shall not be removed or...

  20. Generating User Interfaces with the FUSE-System

    OpenAIRE

    Frank Lonczewski; Siegfried Schreiber

    2017-01-01

    With the FUSE(Formal User interface Specification Environment)-System we present a methodology and a set of integrated tools for the automatic generation of graphical user interfaces. FUSE provides tool-based support for all phases (task-, user-, problem domain analysis, design of the logical user interface, design of user interface in a particular layout style) of the user interface development process. Based on a formal specification of dialogue- and layout guidelines, FUSE allows the autom...

  1. Investigation of fused silica dynamic behaviour

    International Nuclear Information System (INIS)

    Malaise, F.; Chevalier, J.M.; Bertron, I.; Malka, F.

    2006-01-01

    The survivability of the fused silica shields to shrapnel impacts is a key factor for the affordable operation of the intense laser irradiation future facility Laser Mega Joule (LMJ). This paper presents experimental data and computational modelling for LMJ fused silica upon shock wave loading and unloading. Gas-gun flyer plate impact and explosively driven tests have been conducted to investigate the dynamic behaviour of this material. Hugoniot states and the Hugoniot Elastic Limit of LMJ fused silica have been obtained. These experimental data are useful for determining some constitutive model constants of the 'Crack-Model', a continuum tensile and compressive failure model with friction based. This model has been improved by taking into account nonlinear elasticity. The numerical results obtained by performing computations of the previous tests and some ballistic impact tests are discussed. The numerical comparisons with the experimental data show good agreement. Further developments to simulate the permanent densification and the solid-to-solid phase transformation of fused silica are required. (authors)

  2. 30 CFR 56.12036 - Fuse removal or replacement.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fuse removal or replacement. 56.12036 Section 56.12036 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... § 56.12036 Fuse removal or replacement. Fuses shall not be removed or replaced by hand in an energized...

  3. 30 CFR 57.6502 - Safety fuse.

    Science.gov (United States)

    2010-07-01

    ... blasthole detonates. (d) Fuse shall be cut and capped in dry locations. (e) Blasting caps shall be crimped... the primer and the explosive material are securely in place. (g) Safety fuse shall be ignited only... to be fired, electric initiation systems, igniter cord and connectors, or other nonelectric...

  4. 30 CFR 56.6502 - Safety fuse.

    Science.gov (United States)

    2010-07-01

    ... be cut and capped in dry locations. (e) Blasting caps shall be crimped to fuse only with implements... material are securely in place. (g) Safety fuse shall be ignited only with devices designed for that... initiation systems, igniter cord and connectors, or other nonelectric initiation systems shall be used...

  5. Fused aromatic thienopyrazines: structure, properties and function

    KAUST Repository

    Mondal, Rajib; Ko, Sangwon; Bao, Zhenan

    2010-01-01

    Recent development of a fused aromatic thieno[3.4-b]pyrazine system and their application in optoelectronic devices are reviewed. Introduction of a fused aromatic unit followed by side chain engineering, dramatically enhanced the charge carrier

  6. Three-dimensional printing of transparent fused silica glass

    Science.gov (United States)

    Kotz, Frederik; Arnold, Karl; Bauer, Werner; Schild, Dieter; Keller, Nico; Sachsenheimer, Kai; Nargang, Tobias M.; Richter, Christiane; Helmer, Dorothea; Rapp, Bastian E.

    2017-04-01

    Glass is one of the most important high-performance materials used for scientific research, in industry and in society, mainly owing to its unmatched optical transparency, outstanding mechanical, chemical and thermal resistance as well as its thermal and electrical insulating properties. However, glasses and especially high-purity glasses such as fused silica glass are notoriously difficult to shape, requiring high-temperature melting and casting processes for macroscopic objects or hazardous chemicals for microscopic features. These drawbacks have made glasses inaccessible to modern manufacturing technologies such as three-dimensional printing (3D printing). Using a casting nanocomposite, here we create transparent fused silica glass components using stereolithography 3D printers at resolutions of a few tens of micrometres. The process uses a photocurable silica nanocomposite that is 3D printed and converted to high-quality fused silica glass via heat treatment. The printed fused silica glass is non-porous, with the optical transparency of commercial fused silica glass, and has a smooth surface with a roughness of a few nanometres. By doping with metal salts, coloured glasses can be created. This work widens the choice of materials for 3D printing, enabling the creation of arbitrary macro- and microstructures in fused silica glass for many applications in both industry and academia.

  7. Fuse Modeling for Reliability Study of Power Electronic Circuits

    DEFF Research Database (Denmark)

    Bahman, Amir Sajjad; Iannuzzo, Francesco; Blaabjerg, Frede

    2017-01-01

    This paper describes a comprehensive modeling approach on reliability of fuses used in power electronic circuits. When fuses are subjected to current pulses, cyclic temperature stress is introduced to the fuse element and will wear out the component. Furthermore, the fuse may be used in a large......, and rated voltage/current are opposed to shift in time to effect early breaking during the normal operation of the circuit. Therefore, in such cases, a reliable protection required for the other circuit components will not be achieved. The thermo-mechanical models, fatigue analysis and thermo...

  8. Thiophene fused azacoronenes: regioselective synthesis, self organization, charge transport, and its incorporation in conjugated polymers

    Science.gov (United States)

    Liu, Yi; He, Bo

    2015-09-15

    A regioselective synthesis of an azacoronene fused with two peripheral thiophene groups has been realized through a concise synthetic route. The resulting thienoazacoronene (TAC) derivatives show high degree of self-organization in solution, in single crystals, in the bulk, and in spuncast thin films. Spuncast thin film field-effect transistors of the TACs exhibited mobilities up to 0.028 cm.sup.2V.sup.-1 S.sup.-1, which is among the top field effect mobilities for solution processed discotic materials. Organic photovoltaic devices using TAC-containing conjugated polymers as the donor material exhibited a high open-circuit voltage of 0.89 V, which was ascribable to TAC's low-lying highest occupied molecular orbital energy level.

  9. Influence of System Parameters on Fuse Protection Use in Regenerative DC Drives

    Directory of Open Access Journals (Sweden)

    Isa Salman Qamber

    2009-06-01

    Full Text Available Current limiting fuses are widely used to protect the thyristors in DC drive systems. One very important problem is the choice of the correct voltage rating for fuses protecting regenerative DC drives, where many types of fault may occur, which makes fuse protection difficult. In the event of a commutation failure while regenerating, the fuses need to interrupt the loop supplied by the AC and DC voltages acting in series, which is the most difficult case for protection by fuses. In this paper a detailed study of the complete interruption process has been investigated by modeling of arcing process of the fuse protection against the regenerative circuit internal commutation fault. The effect of varying the motor time constant, supply impedance, number of fuses used to clear the fault and DC machine rating on the total transient response is studied. The model of a 200 A fuse is employed in this study. Fuses in series with both the semiconductor devices (F1 and fuses in AC lines (F2 are considered. Comparison was made between arc energy produced for fuses protecting the regenerative circuit if failure occurs, with the arc energy produced in a standard AC test in order to investigate the required voltage rating for the fuse.

  10. Using cyclopenta[2,1-b:3,4-c']dithiophene-4-one as a building block for low-bandgap conjugated copolymers applied in solar cells.

    Science.gov (United States)

    Zhang, Wei; Cao, Jiamin; Liu, Ying; Xiao, Zuo; Zhu, Weiguo; Zuo, Qiqun; Ding, Liming

    2012-09-26

    A novel electron-accepting unit cyclopenta[2,1-b:3,4-c']dithiophene-4-one (CPDTO-c'), which is an isomer of CPDTO-b' was developed. CPDTO-c' can be incorporated into the D-A backbone through 5, 7 positions. The 2 position of CPDTO-c' can be easily functionalized with an electron-withdrawing chain. By copolymerizing CPDTO-c' with four different donor units: benzo[1,2-b:4,5-b']dithiophene (BDT), dithieno[3,2-b:2',3'-d]silole (DTS), carbazole, and fluorene, four new conjugated copolymers P1-P4 were obtained. All these polymers have good solubility and low-lying HOMO energy levels (-5.41 ∼ -5.92 eV). Among them, P1 and P2 exhibit broad absorption and narrow optical bandgaps of 1.91 and 1.72 eV, respectively. Solar cells based on P1/PC(71) BM afforded a PCE up to 2.72% and a high V(oc) up to ∼0.9 V. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Fused aromatic thienopyrazines: structure, properties and function

    KAUST Repository

    Mondal, Rajib

    2010-01-01

    Recent development of a fused aromatic thieno[3.4-b]pyrazine system and their application in optoelectronic devices are reviewed. Introduction of a fused aromatic unit followed by side chain engineering, dramatically enhanced the charge carrier mobility in thin film transistor devices and mobilities up to 0.2 cm2/Vs were achieved. The optoelectronic properties of these fused aromatic thienopyrazine polymers (Eg = 1.3 to 1.6 eV, HOMO = -4.9 to -5.2 V) were tuned by introduction of various fused aromatic rings within thienopyrazine. By balancing the fundamental properties of these polymers, both high charge carrier mobilities and moderate PCEs in solar cells were achieved. Further, effects of copolymerizing units are discussed. Low band gap semiconducting polymer (Eg ∼ 1 eV) with high field effect mobility (0.044 cm2/Vs) was obtained using cyclopentadithiophene as copolymerizing unit. Finally, a molecular design approach to enhance the absorption coefficients is discussed, which resulted in improved power conversion efficiency in bulk heterojunction solar cells. © 2010 The Royal Society of Chemistry.

  12. Functional Use Database (FUse)

    Data.gov (United States)

    U.S. Environmental Protection Agency — There are five different files for this dataset: 1. A dataset listing the reported functional uses of chemicals (FUse) 2. All 729 ToxPrint descriptors obtained from...

  13. Process for manufacturing hollow fused-silica insulator cylinder

    Science.gov (United States)

    Sampayan, Stephen E.; Krogh, Michael L.; Davis, Steven C.; Decker, Derek E.; Rosenblum, Ben Z.; Sanders, David M.; Elizondo-Decanini, Juan M.

    2001-01-01

    A method for building hollow insulator cylinders that can have each end closed off with a high voltage electrode to contain a vacuum. A series of fused-silica round flat plates are fabricated with a large central hole and equal inside and outside diameters. The thickness of each is related to the electron orbit diameter of electrons that escape the material surface, loop, and return back. Electrons in such electron orbits can support avalanche mechanisms that result in surface flashover. For example, the thickness of each of the fused-silica round flat plates is about 0.5 millimeter. In general, the thinner the better. Metal, such as gold, is deposited onto each top and bottom surface of the fused-silica round flat plates using chemical vapor deposition (CVD). Eutectic metals can also be used with one alloy constituent on the top and the other on the bottom. The CVD, or a separate diffusion step, can be used to defuse the deposited metal deep into each fused-silica round flat plate. The conductive layer may also be applied by ion implantation or gas diffusion into the surface. The resulting structure may then be fused together into an insulator stack. The coated plates are aligned and then stacked, head-to-toe. Such stack is heated and pressed together enough to cause the metal interfaces to fuse, e.g., by welding, brazing or eutectic bonding. Such fusing is preferably complete enough to maintain a vacuum within the inner core of the assembled structure. A hollow cylinder structure results that can be used as a core liner in a dielectric wall accelerator and as a vacuum envelope for a vacuum tube device where the voltage gradients exceed 150 kV/cm.

  14. 29 CFR 1926.907 - Use of safety fuse.

    Science.gov (United States)

    2010-07-01

    ... way shall be forbidden. (b) The hanging of a fuse on nails or other projections which will cause a...-called “drop fuse” method of dropping or pushing a primer or any explosive with a lighted fuse attached...

  15. Dedication for Safety-Related Fuses used in Class-1E Power System

    International Nuclear Information System (INIS)

    Hong, Younghee

    2014-01-01

    The safety-related fuses used in class-1E power system provide overcurrent protection for electrical system and isolate the class 1E circuit from a fault or overload condition. These days, the number of nuclear grade suppliers has been reduced. Accordingly, commercial grade, instead of safety-related, fuses are procured and used in the utilities through the dedication process. Therefore, this paper introduces the commercial grade fuse dedication process/engineering and how to assure the quality requirements with this process and engineering. The fuses used in class-1E power system are to protect overcurrent and to isolate fault. Therefore the fuse for acceptance in order to improve the quality and reliability for commercial grade fuses shall be dedicated. The fuse resistance value may be useful as an indicator of acceptance. The current carrying capacity test can change the fuse performance properties. Therefore these critical characteristics are needed for additional review and analysis with fuse manufactures

  16. Is Oxidative Stress in Mice Brain Regions Diminished by 2-[(2,6-Dichlorobenzylideneamino]-5,6-dihydro-4H-cyclopenta[b]thiophene-3-carbonitrile?

    Directory of Open Access Journals (Sweden)

    A. C. Fortes

    2013-01-01

    Full Text Available 2-[(2,6-Dichlorobenzylideneamino]-5,6-dihydro-4H-cyclopenta[b]thiophene-3-carbonitrile, 5TIO1, is a new 2-aminothiophene derivative with promising pharmacological activities. The aim of this study was to evaluate its antioxidant activity in different areas of mice central nervous system. Male Swiss adult mice were intraperitoneally treated with Tween 80 dissolved in 0.9% saline (control group and 5TIO1 (0.1, 1, and 10 mg kg−1. Brain homogenates—hippocampus, striatum, frontal cortex, and cerebellum—were obtained after 24 h of observation. Superoxide dismutase and catalase activities, lipid peroxidation and nitrite content were measured using spectrophotometrical methods. To clarify the 5TIO1’s mechanism on oxidative stress, western blot analysis of superoxide dismutase and catalase was also performed. 5TIO1 decreased lipid peroxidation and nitrite content in all brain areas and increased the antioxidant enzymatic activities, specially, in cerebellum. The data of Western blot analysis did not demonstrate evidence of the upregulation of these enzymes after the administration of this compound. Our findings strongly support that 5TIO1 can protect the brain against neuronal damages regularly observed during neuropathologies.

  17. Fused upper central incisors: management of two clinical cases

    OpenAIRE

    Sfasciotti, Gian Luca; Marini, Roberta; Bossù, Maurizio; Ierardo, Gaetano; Annibali, Susanna

    2012-01-01

    This paper reports the management of two clinical cases, in which the upper right central incisor was fused with a supernumerary tooth and the upper left central incisor was macrodontic. A radiographic examination revealed that the fused teeth had two separate roots. Hemisectioning of the fused teeth was performed, the supernumerary portion was extracted and the remaining part was reshaped to remove any sharp margins and to achieve a normal morphology. The macrodontic central incisors were no...

  18. Computational model of exploding metallic fuses for multimegajoule switching

    International Nuclear Information System (INIS)

    Lindemuth, I.R.; Brownell, J.H.; Greene, A.E.; Nickel, G.H.; Oliphant, T.A.; Weiss, D.L.

    1985-01-01

    A new model for determining the time-dependent behavior of exploding metallic fuses is formulated. The model draws on an atomic data base and gives insight into the temporal behavior of the material density and temperature of the fuse as well as the nonlinear electrical circuit interaction. The model includes an embedding insulating tamper and leads to a plausible explanation of fuse ''restrike.'' The model predicts time-scale compression of 500 for inductive store systems powered by explosive driven magnetic flux compression generators. A scenario for achieving multimegajoule foil implosions is predicted

  19. Bilateral maxillary fused second and third molars: a rare occurrence.

    Science.gov (United States)

    Liang, Rui-Zhen; Wu, Jin-Tao; Wu, You-Nong; Smales, Roger J; Hu, Ming; Yu, Jin-Hua; Zhang, Guang-Dong

    2012-12-01

    This case report describes the diagnosis and endodontic therapy of maxillary fused second and third molars, using cone-beam computed tomography (CBCT). A 31-year-old Chinese male, with no contributory medical or family/social history, presented with throbbing pain in the maxillary right molar area following an unsuccessful attempted tooth extraction. Clinical examination revealed what appeared initially to be a damaged large extra cusp on the buccal aspect of the distobuccal cusp of the second molar. However, CBCT revealed that a third molar was fused to the second molar. Unexpectedly, the maxillary left third molar also was fused to the second molar, and the crown of an unerupted supernumerary fourth molar was possibly also fused to the apical root region of the second molar. Operative procedures should not be attempted without adequate radiographic investigation. CBCT allowed the precise location of the root canals of the right maxillary fused molar teeth to permit successful endodontic therapy, confirmed after 6 months.

  20. Quantification of Residual Stress from Photonic Signatures of Fused Silica

    Science.gov (United States)

    Cramer, K. Elliott; Hayward, Maurice; Yost, William E.

    2013-01-01

    A commercially available grey-field polariscope (GFP) instrument for photoelastic examination is used to assess impact damage inflicted upon the outer-most pane of Space Shuttle windows made from fused silica. A method and apparatus for calibration of the stress-optic coefficient using four-point bending is discussed. The results are validated on known material (acrylic) and are found to agree with literature values to within 6%. The calibration procedure is then applied to fused-silica specimens and the stress-optic coefficient is determined to be 2.43 +/- 0.54 x 10(exp -12)/Pa. Fused silica specimens containing impacts artificially made at NASA's Hypervelocity Impact Technology Facility (HIT-F), to simulate damage typical during space flight, are examined. The damage sites are cored from fused silica window carcasses and examined with the GFP. The calibrated GFP measurements of residual stress patterns surrounding the damage sites are presented. Keywords: Glass, fused silica, photoelasticity, residual stress

  1. Fiber fuse behavior in kW-level continuous-wave double-clad field laser

    International Nuclear Information System (INIS)

    Sun Jun-Yi; Xiao Qi-Rong; Li Dan; Wang Xue-Jiao; Zhang Hai-Tao; Gong Ma-Li; Yan Ping

    2016-01-01

    In this study, original experimental data for fiber fuse in kW-level continuous-wave (CW) high power double-clad fiber (DCF) laser are reported. The propagating velocity of the fuse is 9.68 m/s in a 3.1-kW Yb-doped DCF laser. Three other cases in Yb-doped DCF are also observed. We think that the ignition of fiber fuse is caused by thermal mechanism, and the formation of bullet-shaped tracks is attributed to the optical discharge and temperature gradient. The inducements of initial fuse and formation of bullet-shaped voids are analyzed. This investigation of fiber fuse helps better understand the fiber fuse behavior, in order to avoid the catastrophic destruction caused by fiber fuse in high power fiber laser. (paper)

  2. Fuse and application of said fuse to the construction of an emergency shutdown system for a nuclear reactor

    International Nuclear Information System (INIS)

    Taulier, H.H.L.; Brugeille, G.

    1978-01-01

    A fuse device for an automatic emergency shutdown system in fast reactors provides a coupling between a casing tube placed within a fuel can and a series of neutron-absorbing masses held together above the reactor core under normal operating conditions but released in free fall to the lower portion of the casing tube at the level of the reactor core as a result of melting of the fuse when operating characteristics such as temperature or neutron flux attain a level which exceeds a predetermined threshold

  3. Fuse and application of said fuse to the construction of an emergency shutdown system for a nuclear reactor

    International Nuclear Information System (INIS)

    Taulier, H.H.L.; Brugeilles, G.

    1976-01-01

    A fuse device for an automatic emergency shutdown system in fast reactors provides a coupling between a casing tube placed within a fuel can and a series of neutron-absorbing masses held together above the reactor core under normal operating conditions. They are released in free fall to the lower portion of the casing tube at the level of the reactor core as a result of melting of the fuse when operating characteristics such as temperature or neutron flux attain a level which exceeds a predetermined threshold

  4. and 8-Membered Oxygen-containing Benzo-fused Rings using ...

    African Journals Online (AJOL)

    NJD

    A number of benzo-fused oxygen-containing heterocycles were synthesized from allyl-3-isopropoxy-4-methoxybenzaldehyde using metathesis or an alkene isomerization-metathesis sequence as key synthetic steps. Benzo-fused compounds thus formed included a 3,6-dihydro-1H-2-benzoxocine, ...

  5. Outbursts In Symbiotic Binaries (FUSE 2000)

    Science.gov (United States)

    Kenyon, Scott J.; Sonneborn, George (Technical Monitor)

    2002-01-01

    During the past year, we made good progress on analysis of FUSE observations of the symbiotic binary Z And. For background, Z And is a binary system composed of a red giant and a hot component of unknown status. The orbital period is roughly 750 days. The hot component undergoes large-scale eruptions every 10-20 yr. An outburst began several years ago, triggering this FUSE opportunity. First, we obtained an excellent set of ground-based optical data in support, of the FUSE observations. We used FAST, a high throughput low resolution spectrograph on the 1.5-m telescope at Mt. Hopkins, Arizona. A 300 g/ mm grating blazed at 4750 A, a 3 in. slit, and a thinned Loral 512 x 2688 CCD gave us spectra covering 3800-7500 A at a resolution of 6 A. The wavelength solution for each spectrum has a probable error of +/- 0.5 A or better. Most of the resulting spectra have moderate signal-to-noise, S/.N approx. greater than 30 per pixel. The time coverage for these spectra is excellent. Typically, we acquired spectra every 1-2 nights during dark runs at Mt. Hopkins. These data cover most of the rise and all of the decline of the recent outburst. The spectra show a wealth of emission lines, including H I, He I, He II, [Fe V11], and the Raman scattering bands at 6830 A and 7088 A. The Raman bands and other high ionization features vary considerably throughout the outburst. These features will enable us to correlate variations in the FUSE spectra with variations in the optical spectra. Second, we began an analysis of FUSE spectra of Z And. We have carefully examined the spectra, identifying real features and defects. We have identified and measured fluxes for all strong emission lines, including the O VI doublet at 1032 A and 1038 A. These and several other strong emission lines display pronounced P Cygni absorption components indicative of outgrowing gas. We will attempt to correlate these velocities with similar profiles observed on optical spectra. The line velocities - together

  6. ELIMINATING NEGETIVE EFFECT OF INVERTER-BASED DGs ON FUSE-RECLOSER COORDINATION IN DISTRIBUTION SYSTEMS

    OpenAIRE

    shakarami, mahmoudreza; namdari, farhad; salehi, moslem

    2015-01-01

    Despite many advantages of distributed generation (DG) sources, they may have a negative effect on the protection of distribution systems. In a distribution system, fuse-recloser protection scheme is designed such that the recloser could operate faster than the fuse to prevent fuse burning; but, the presence of DGs in fault conditions may lead to increased fuse current and thus faster performance of the fuse than the recloser and lack of coordination. In this paper, effect of DGs on fuse-recl...

  7. Fusing Facial Features for Face Recognition

    Directory of Open Access Journals (Sweden)

    Jamal Ahmad Dargham

    2012-06-01

    Full Text Available Face recognition is an important biometric method because of its potential applications in many fields, such as access control, surveillance, and human-computer interaction. In this paper, a face recognition system that fuses the outputs of three face recognition systems based on Gabor jets is presented. The first system uses the magnitude, the second uses the phase, and the third uses the phase-weighted magnitude of the jets. The jets are generated from facial landmarks selected using three selection methods. It was found out that fusing the facial features gives better recognition rate than either facial feature used individually regardless of the landmark selection method.

  8. Hole-assisted fiber based fiber fuse terminator supporting 22 W input

    Science.gov (United States)

    Tsujikawa, Kyozo; Kurokawa, Kenji; Hanzawa, Nobutomo; Nozoe, Saki; Matsui, Takashi; Nakajima, Kazuhide

    2018-05-01

    We investigated the air hole structure in hole-assisted fiber (HAF) with the aim of terminating fiber fuse propagation. We focused on two structural parameters c/MFD and S1/S2, which are related respectively to the position and area of the air holes, and mapped their appropriate values for terminating fiber fuse propagation. Here, MFD is the mode field diameter, c is the diameter of an inscribed circle linking the air holes, S1 is the total area of the air holes, and S2 is the area of a circumscribed circle linking the air holes. On the basis of these results, we successfully realized a compact fiber fuse terminator consisting of a 1.35 mm-long HAF, which can terminate fiber fuse propagation even with a 22 W input. In addition, we observed fiber fuse termination using a high-speed camera. We additionally confirmed that the HAF-based fiber fuse terminator is effective under various input power conditions. The penetration length of the optical discharge in the HAF was only less than 300 μm when the input power was from 2 to 22 W.

  9. Fused upper central incisors: management of two clinical cases.

    Science.gov (United States)

    Sfasciotti, Gian Luca; Marini, Roberta; Bossù, Maurizio; Ierardo, Gaetano; Annibali, Susanna

    2011-03-01

    This paper reports the management of two clinical cases, in which the upper right central incisor was fused with a supernumerary tooth and the upper left central incisor was macrodontic. A radiographic examination revealed that the fused teeth had two separate roots. Hemisectioning of the fused teeth was performed, the supernumerary portion was extracted and the remaining part was reshaped to remove any sharp margins and to achieve a normal morphology. The macrodontic central incisors were not treated. At 12-months post-surgery there were no periodontal problems and no hypersensitivity. Orthodontic treatment was performed to appropriately align the maxillary teeth and to correct the malocclusion.

  10. [Effects of laser welding on bond of porcelain fused cast pure titanium].

    Science.gov (United States)

    Zhu, Juan-fang; He, Hui-ming; Gao, Bo; Wang, Zhong-yi

    2006-04-01

    To investigate the influence of the laser welding on bond of porcelain fused to cast pure titanium. Twenty cast titanium plates were divided into two groups: laser welded group and control group. The low-fusing porcelain was fused to the laser welded cast pure titanium plates at fusion zone. The bond strength of the porcelain to laser welded cast pure titanium was measured by the three-point bending test. The interface of titanium and porcelain was investigated by scanning electron microscopy (SEM) and energy depressive X-ray detector (EDX). The non-welded titanium plates were used as comparison. No significant difference of the bond strength was found between laser-welded samples [(46.85 +/- 0.76) MPa] and the controls [(41.71 +/- 0.55) MPa] (P > 0.05). The SEM displayed the interface presented similar irregularities with a predominance. The titanium diffused to low-fusing porcelain, while silicon and aluminum diffused to titanium basement. Laser welding does not affect low-fusing porcelain fused to pure titanium.

  11. Effect on canine lymphocyte function of 144Ce inhaled in fused clay particles

    International Nuclear Information System (INIS)

    Benjamin, S.A.; Ferris, A.C.

    1974-01-01

    Beagle dogs exposed by inhalation to 144 Ce in fused clay particles develop a persistent lymphopenia and the remaining peripheral lymphocytes in these dogs show a depressed in vitro response to plant mitogens. These studies were designed to evaluate the cellular basis for this defect. The survival and growth of lymphocytes from irradiated and control dogs were evaluated through 96 hours of culture. Many irradiated lymphocytes that were viable in vivo died within 24 hours in vitro. The remaining lymphocytes appeared to grow normally indicating that the early in vitro death was responsible for at least a portion of the difference between irradiated and control lymphocyte cultures. A second experiment was designed to determine if any humoral factors in plasma of irradiated dogs were responsible for the poor response of the lymphocytes. Lymphocytes from irradiated and control dogs were grown with plasma from both types of animals. Heterologous plasma had no apparent effect on lymphocyte growth, indicating that humoral factors were not involved. (U.S.)

  12. Renal cell carcinoma in patient with crossed fused renal ectopia

    Directory of Open Access Journals (Sweden)

    Ozgur Cakmak

    2016-01-01

    Full Text Available Primary renal cell carcinomas have rarely been reported in patients with crossed fused renal ectopia. We presented a patient with right to left crossed fused kidney harbouring renal tumor. The most frequent tumor encountered in crossed fused renal ectopia is renal cell carcinoma. In this case, partial nephrectomy was performed which pave way to preservation of the uninvolved both renal units. Due to unpredictable anatomy, careful preoperative planning and meticulous delineation of renal vasculature is essential for preservation of the uninvolved renal units.

  13. RR Tel: Getting Under the Flux Limit: An Observation with FUSE

    Science.gov (United States)

    Sonnenborn, George (Technical Monitor); Kenyon, Scott J.

    2004-01-01

    The goal of this program is to acquire a FUSE spectrum of the symbiotic binary RR Tel. With these data, we plan to derive improved constraints on the hot component, the nebula, and perhaps the red giant wind. Based on results from AG Dra, we should also be able to use some line detections to improve atomic parameters for high ionization emission lines. This results would benefit the general FUSE community. As of this writing, the FUSE observation of RR Tel has not been made. Because RR Tel is a very bright UV source, the FUSE team is assessing the likelihood that RR Tel will have an adverse affect on the instrument.

  14. HVI Ballistic Limit Characterization of Fused Silica Thermal Panes

    Science.gov (United States)

    Miller, J. E.; Bohl, W. D.; Christiansen, E. L.; Davis, B. A.; Deighton, K. D.

    2015-01-01

    Fused silica window systems are used heavily on crewed reentry vehicles, and they are currently being used on the next generation of US crewed spacecraft, Orion. These systems improve crew situational awareness and comfort, as well as, insulating the reentry critical components of a spacecraft against the intense thermal environments of atmospheric reentry. Additionally, these materials are highly exposed to space environment hazards like solid particle impacts. This paper discusses impact studies up to 10 km/s on a fused silica window system proposed for the Orion spacecraft. A ballistic limit equation that describes the threshold of perforation of a fuse silica pane over a broad range of impact velocities, obliquities and projectile materials is discussed here.

  15. Liquefier Dynamics in Fused Deposition

    DEFF Research Database (Denmark)

    Bellini, Anna; Guceri, Selcuk; Bertoldi, Maurizio

    2004-01-01

    Layered manufacturing (LM) is an evolution of rapid prototyping (RP) technology whereby a part is built in layers. Fused deposition modeling (FDM) is a particular LM technique in which each section is fabricated through vector style deposition of building blocks, called roads, which...

  16. Technological aspects of using protective fuses in low-voltage mine networks

    Energy Technology Data Exchange (ETDEWEB)

    Kowalski, Z; Pudelko, H

    1986-04-01

    Protection systems are evaluated for mining equipment used in underground coal mining in Poland. Operation of contactor switches is analyzed. Systems for protection of vacuum contactor switches from overload are comparatively evaluated. Types of current reducers are reviewed. Design of the aM protection fuse which is activated only when overload current exceeds the limiting level is analyzed. Protection fuses with the aM characteristic meeting IEC and VDE requirements for fuses used in SV5, SV7 and SV8 vacuum contactors for power networks of up to 1000 V are evaluated. Characteristics of the vacuum contactors manufactured in Poland are given in 6 diagrams and 2 tables. Reliability of the vacuum contactors with aM protection fuses is analyzed. 8 references.

  17. Quantification of residual stress from photonic signatures of fused silica

    International Nuclear Information System (INIS)

    Cramer, K. Elliott; Yost, William T.; Hayward, Maurice

    2014-01-01

    A commercially available grey-field polariscope (GFP) instrument for photoelastic examination is used to assess impact damage inflicted upon the outer-most pane of Space Shuttle windows made from fused silica. A method and apparatus for calibration of the stress-optic coefficient using four-point bending is discussed. The results are validated on known material (acrylic) and are found to agree with literature values to within 6%. The calibration procedure is then applied to fused-silica specimens and the stress-optic coefficient is determined to be 2.43 ± 0.54 × 10 −12 Pa −1 . Fused silica specimens containing impacts artificially made at NASA’s Hypervelocity Impact Technology Facility (HIT-F), to simulate damage typical during space flight, are examined. The damage sites are cored from fused silica window carcasses and examined with the GFP. The calibrated GFP measurements of residual stress patterns surrounding the damage sites are presented

  18. Full spectrum endoscopy (FUSE) versus standard forward-viewing endoscope (SFV) in a high-risk population

    DEFF Research Database (Denmark)

    Roepstorff, Søren; Hadi, Sabah Anwar; Rasmussen, Morten

    2017-01-01

    OBJECTIVES: To investigate the diagnostic performance of Full Spectrum Endoscopy (FUSE) compared to a conventional standard forward-viewing endoscope (SFV). The primary outcome was adenoma detection rate (ADR) and mean adenoma detection. Secondary outcome was feasibility of FUSE opposed to SFV...... intubation time, fentanyl and midazolam sedation, CRC detection, ADR, diverticulosis, bowel preparation, patient discomfort and endoscopist difficulty rating. Participants underwent FUSE colonoscopy on days when the FUSE system was available, while the remaining participants had SFV. All colonoscopies were.......1 ± 6.2 min in the FUSE and SFV groups (p = .040). ADR was 67.0% and 59.6% (p = .097), while the mean adenoma detection was 1.79 and 1.38 (p = .022) in the FUSE and SFV groups. Endoscopists reported increased difficulty rating with FUSE compared to SFV (p > .001). CONCLUSION: FUSE colonoscopy provides...

  19. Hybrid Z-Θ Pinches with fused capacitor banks

    International Nuclear Information System (INIS)

    Grandey, R.; Gersten, M.; Loter, N.; Rauch, J.; Rostoker, N.; Thompson, W.; Ware, K.

    1987-01-01

    The Hybrid Z-Θ Pinch circuit equations in the thin shell model were reexamined to see what advantages can be obtained by using a fused, high-energy (>--1MJ) bank driver. The DNA ACE facility at MLI utilizes a 36 μF capacitor band which can be charged to 120 kV to provide 250 kJ of stored energy. This configuration appears to be very appropriate to test the performance of a hybrid-stabilized fused-bank driven pinch. The circuit analyses suggest that the energy transfer efficiency from the bank to a pinched plasma can be increased from less than 1%, for a nonfused bank, to about 10% for a fused configuration. In the applicable region of parameter space, the Hybrid Pinch does not increase the efficiency of energy transfer into the plasma over that obtainable from a Z-pinch. The additional stability may allow larger initial radii to be used with concomitant improved coupling into radiation above 1 keV

  20. Exploding metallic fuse physics experiments

    International Nuclear Information System (INIS)

    Goforth, J.H.; Hackett, K.E.; Lindemuth, I.R.; Lopez, E.A.; McCullough, W.F.; Dona, H.; Reinovsky, R.E.

    1986-01-01

    The ultimate practicality of inductive pulse compression systems as drivers for energetic plasma implosions hinges on the development of a suitable opening switch capable of interrupting tons of megamp currents in time scales of a few hundred nanoseconds while withstanding L(dI/dt) voltages of a megavolt or more. 1. Exploding metallic foils (fuses) are a candidate for switching elements in the inductive store pulsed power systems used in the Los Alamos and Air Force Weapons Laboratory foil implosion X-ray source generation programs. To verify or modify new theoretical and computational predictions about the electrical and hydrodynamic behavior of exploding metallic foils used as fuses. The authors have initiated a new series of small scale capacitor bank driven fuse experiments. The experiments represent an extension of previous experiments, but in the new series a foil geometry more amenable to theoretical and computational analysis is used. The metallic foil (aluminum or copper) is laminated between two thin layers of insulating material (mylar or kaptan). Adjacent to one layer of insulation is a much heavier backing insulator (polyethylene) whereas air is adjacent to the other layer. Because of the differing masses on the two sides of the foil, the foil expansion and hydrodynamic motion is essentially one-sided and the layer of insulation on the expanding side becomes a readily-characterizable ''flyer'' which provides a controlled amount of hydrodynamic tamping. In addition to the usual voltage, current, and dI/dt electrical measurements, time-resolved spectrometer measurements are used to determine the temperature of the expanding metallic foil. Post-shot examination of the flyer and the insulation impacted by the flyer gives insight into the experimental behavior

  1. Morphological evaluation of maxillary second molars with fused roots: a micro-CT study.

    Science.gov (United States)

    Ordinola-Zapata, R; Martins, J N R; Bramante, C M; Villas-Boas, M H; Duarte, M H; Versiani, M A

    2017-12-01

    To evaluate the internal and external morphologies of fused-rooted maxillary second molars by means of micro-computed tomography (micro-CT) analysis. A total of 100 fused-rooted maxillary second molars from a Brazilian subpopulation were divided into six groups according to the root morphology. The samples were scanned at a resolution of 19.6 μm and evaluated with regard to the external morphology of the roots, the root canal configuration, the percentage frequency of C-shaped canals and isthmuses, as well as the morphology of the root canal system at 1, 2 and 3 mm from the anatomical apex of the fused roots. The most prevalent root canal fusions were type 1, mesiobuccal root fused with distobuccal root (32%), followed by type 3, DB root fused with P root (27%), and type 4, MB root fused with DB root, and P root fused with MB or DB roots (21%). The prevalence of C-shaped root canal systems were 22%. Depending on the type of root fusion, the percentage frequency of isthmuses in the apical level varied from 9.3% to 42.8%, whilst the presence of apical deltas ranged from 18.5% to 57.1% of teeth. The root canal system of maxillary second molars with fused roots may have a high incidence of merging canals, isthmuses, apical deltas and C-shaped configurations. © 2017 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  2. Electro-Deformation of Fused Cells in a Microfluidic Array Device

    Directory of Open Access Journals (Sweden)

    Yan Liu

    2016-11-01

    Full Text Available We present a new method of analyzing the deformability of fused cells in a microfluidic array device. Electrical stresses—generated by applying voltages (4–20 V across discrete co-planar microelectrodes along the side walls of a microfluidic channel—have been used to electro-deform fused and unfused stem cells. Under an electro-deformation force induced by applying an alternating current (AC signal, we observed significant electro-deformation phenomena. The experimental results show that the fused stem cells were stiffer than the unfused stem cells at a relatively low voltage (<16 V. However, at a relatively high voltage, the fused stem cells were more easily deformed than were the unfused stem cells. In addition, the electro-deformation process is modeled based on the Maxwell stress tensor and structural mechanics of cells. The theoretical results show that a positive correlation is found between the deformation of the cell and the applied voltage, which is consistent with the experimental results. Combined with a numerical analysis and experimental study, the results showed that the significant difference of the deformation ratio of the fused and unfused cells is not due to their size difference. This demonstrates that some other properties of cell membranes (such as the membrane structure were also changed in the electrofusion process, in addition to the size modification of that process.

  3. Refractive index sensors based on the fused tapered special multi-mode fiber

    Science.gov (United States)

    Fu, Xing-hu; Xiu, Yan-li; Liu, Qin; Xie, Hai-yang; Yang, Chuan-qing; Zhang, Shun-yang; Fu, Guang-wei; Bi, Wei-hong

    2016-01-01

    In this paper, a novel refractive index (RI) sensor is proposed based on the fused tapered special multi-mode fiber (SMMF). Firstly, a section of SMMF is spliced between two single-mode fibers (SMFs). Then, the SMMF is processed by a fused tapering machine, and a tapered fiber structure is fabricated. Finally, a fused tapered SMMF sensor is obtained for measuring external RI. The RI sensing mechanism of tapered SMMF sensor is analyzed in detail. For different fused tapering lengths, the experimental results show that the RI sensitivity can be up to 444.517 81 nm/RIU in the RI range of 1.334 9—1.347 0. The RI sensitivity is increased with the increase of fused tapering length. Moreover, it has many advantages, including high sensitivity, compact structure, fast response and wide application range. So it can be used to measure the solution concentration in the fields of biochemistry, health care and food processing.

  4. Peripheral neuropathy

    Science.gov (United States)

    ... peripheral; Neuritis - peripheral; Nerve disease; Polyneuropathy; Chronic pain - peripheral neuropathy ... Philadelphia, PA: Elsevier; 2016:chap 107. Shy ME. Peripheral neuropathies. In: Goldman L, Schafer AI, eds. Goldman's Cecil ...

  5. PDI Derivative through Fine-Tuning Molecular Structure for Fullerene-Free Organic Solar Cells

    KAUST Repository

    Sun, Hua

    2017-08-10

    A perylenediimide (PDI)-based small molecular (SM) acceptor with both an extended π-conjugation and a three dimensional structure concurrently is critical for achieving high performance PDI-based fullerene-free organic solar cells (OSCs). In this work, we designed and synthesized a novel PDI-based SM acceptor possessing both characteristics by fusing PDI units with a spiro core of 4,4’-spirobi[cyclopenta[2,1-b;3,4-b’]dithiophene(SCPDT) through the -position of the thiophene rings. An enhanced strong absorption in the range of 350–520 nm and arisen LUMO energy level of FSP was observed, compared with previous reported acceptor SCPDT-PDI4, in which the PDI units and SCPDT are not fused. OSCs based on PTB7-Th donor and FSP acceptor were fabricated and achieved a power conversion efficiency of up to 8.89% with DPE as an additive. Efficient and complementary photo absorption, favorable phase separation and balanced carrier mobilites in the blend film account for the high photovoltaic performance. This study offers an effective strategy to design high performance PDI-based acceptors.

  6. Non-destructive evaluation of UV pulse laser-induced damage performance of fused silica optics.

    Science.gov (United States)

    Huang, Jin; Wang, Fengrui; Liu, Hongjie; Geng, Feng; Jiang, Xiaodong; Sun, Laixi; Ye, Xin; Li, Qingzhi; Wu, Weidong; Zheng, Wanguo; Sun, Dunlu

    2017-11-24

    The surface laser damage performance of fused silica optics is related to the distribution of surface defects. In this study, we used chemical etching assisted by ultrasound and magnetorheological finishing to modify defect distribution in a fused silica surface, resulting in fused silica samples with different laser damage performance. Non-destructive test methods such as UV laser-induced fluorescence imaging and photo-thermal deflection were used to characterize the surface defects that contribute to the absorption of UV laser radiation. Our results indicate that the two methods can quantitatively distinguish differences in the distribution of absorptive defects in fused silica samples subjected to different post-processing steps. The percentage of fluorescence defects and the weak absorption coefficient were strongly related to the damage threshold and damage density of fused silica optics, as confirmed by the correlation curves built from statistical analysis of experimental data. The results show that non-destructive evaluation methods such as laser-induced fluorescence and photo-thermal absorption can be effectively applied to estimate the damage performance of fused silica optics at 351 nm pulse laser radiation. This indirect evaluation method is effective for laser damage performance assessment of fused silica optics prior to utilization.

  7. Endodontic therapy for a fused mandibular molar.

    Science.gov (United States)

    Rotstein, I; Moshonov, J; Cohenca, N

    1997-06-01

    Variations in tooth morphology present a clinical challenge when endodontic treatment is required. A case of conservative endodontic therapy for a fused mandibular second and third molar is presented.

  8. FFT-enhanced IHS transform method for fusing high-resolution satellite images

    Science.gov (United States)

    Ling, Y.; Ehlers, M.; Usery, E.L.; Madden, M.

    2007-01-01

    Existing image fusion techniques such as the intensity-hue-saturation (IHS) transform and principal components analysis (PCA) methods may not be optimal for fusing the new generation commercial high-resolution satellite images such as Ikonos and QuickBird. One problem is color distortion in the fused image, which causes visual changes as well as spectral differences between the original and fused images. In this paper, a fast Fourier transform (FFT)-enhanced IHS method is developed for fusing new generation high-resolution satellite images. This method combines a standard IHS transform with FFT filtering of both the panchromatic image and the intensity component of the original multispectral image. Ikonos and QuickBird data are used to assess the FFT-enhanced IHS transform method. Experimental results indicate that the FFT-enhanced IHS transform method may improve upon the standard IHS transform and the PCA methods in preserving spectral and spatial information. ?? 2006 International Society for Photogrammetry and Remote Sensing, Inc. (ISPRS).

  9. Colored fused filament fabrication

    OpenAIRE

    Song, Haichuan; Lefebvre, Sylvain

    2017-01-01

    Filament fused fabrication is the method of choice for printing 3D models at low cost, and is the de-facto standard for hobbyists, makers and schools. Unfortunately, filament printers cannot truly reproduce colored objects. The best current techniques rely on a form of dithering exploiting occlusion, that was only demonstrated for shades of two base colors and that behaves differently depending on surface slope. We explore a novel approach for 3D printing colored objects, capable of creating ...

  10. Fungal Systematics and Evolution: FUSE 1

    NARCIS (Netherlands)

    Crous, Pedro W; Schumacher, René K; Wingfield, Michael J; Lombard, Lorenzo; Giraldo, Alejandra; Christensen, Martha; Gardiennet, Alain; Nakashima, Chiharu; Pereira, Olinto L; Smith, Alexander J; Groenewald, Johannes Z

    2015-01-01

    Fungal Systematics and Evolution (FUSE) is introduced as a new series to expedite the publication of issues relating to the epitypification of formerly described species, report new sexual-asexual connections, the merging of sexual and asexual gen¬era following the end of dual nomenclature, and to

  11. Remodeling of peripheral nerve ensheathment during the larval-to-adult transition in Drosophila.

    Science.gov (United States)

    Subramanian, Aswati; Siefert, Matthew; Banerjee, Soumya; Vishal, Kumar; Bergmann, Kayla A; Curts, Clay C M; Dorr, Meredith; Molina, Camillo; Fernandes, Joyce

    2017-10-01

    Over the course of a 4-day period of metamorphosis, the Drosophila larval nervous system is remodeled to prepare for adult-specific behaviors. One example is the reorganization of peripheral nerves in the abdomen, where five pairs of abdominal nerves (A4-A8) fuse to form the terminal nerve trunk. This reorganization is associated with selective remodeling of four layers that ensheath each peripheral nerve. The neural lamella (NL), is the first to dismantle; its breakdown is initiated by 6 hours after puparium formation, and is completely removed by the end of the first day. This layer begins to re-appear on the third day of metamorphosis. Perineurial glial (PG) cells situated just underneath the NL, undergo significant proliferation on the first day of metamorphosis, and at that stage contribute to 95% of the glial cell population. Cells of the two inner layers, Sub-Perineurial Glia (SPG) and Wrapping Glia (WG) increase in number on the second half of metamorphosis. Induction of cell death in perineurial glia via the cell death gene reaper and the Diptheria toxin (DT-1) gene, results in abnormal bundling of the peripheral nerves, suggesting that perineurial glial cells play a role in the process. A significant number of animals fail to eclose in both reaper and DT-1 targeted animals, suggesting that disruption of PG also impacts eclosion behavior. The studies will help to establish the groundwork for further work on cellular and molecular processes that underlie the co-ordinated remodeling of glia and the peripheral nerves they ensheath. © 2017 Wiley Periodicals, Inc. Develop Neurobiol 77: 1144-1160, 2017. © 2017 Wiley Periodicals, Inc.

  12. Nondestructive detection system of faults in fuses using radioisotope

    International Nuclear Information System (INIS)

    Goncalves, D.

    1973-01-01

    A system is developed to show the viability of non-destructive detection of the faults of explosive safety fuses which are manufactured by Fabrica da Estrela do Ministerio do Exercito. The faults are detected by an ion-chamber based on the variation of the intensity of the beta particles that penetrate the fuse which passes through a collimator. The beta particles are emitted by Strontium-90 + Yttrium-90 encapsulated in either stainless steel or aluminum. The concept of 'bucking Voltage' is applied to differentiate electronically the signal generated by the ion-chamber. (author)

  13. Measurements of fuse and resistor characteristics for multi-megajoule capacitor bank application

    International Nuclear Information System (INIS)

    McDonald, K.F.; Smith, T.; Golden, J.; Conley, B.

    1986-01-01

    Experimental tests have been conducted on commercially available fuses and resistors under fast high voltage pulsed (10 μsec) conditions to determine their ability to protect capacitor bank components during faults. NRL's Modified Betatron Accelerator uses two multi-megajoule capacitor banks to power the toroidal and betatron magnetic field coils. The expensive high energy density capacitors in these banks must be protected from excessive peak current, voltage reversal, or charging beyond their electrical ratings in the occurrence of a fault. Adequate protection can be obtained with fuses and resistors in series with each parallel connected capacitor. The fuses must open reliably and hold off high voltage D.C. (10 - 20 kV), and the resistors must conduct high current and di/dt without failing from energy deposition or magnetic forces. The performance of the commercial fuses is well documented at low AC frequencies and currents (60 Hz/100 A) but data was not previously available for the fast high current pulsed conditions that prevail under actual fault conditions. A 20 kV 200 kJ, low inductance capacitor bank and ignitron switch were used to conduct the experiments. Peak currents in the fuses were approximately 170 kA at t - 6.5 μs. The final fuse hold-off voltage exceeded 8 kV. Currents in the resistors ranged from - 20 - 40 kA per resistor. The experimental results have been compared to the manufacturers data from minimum melt and maximum let-through and to exploding bridge wire computer models

  14. 30 CFR 75.601-3 - Short circuit protection; dual element fuses; current ratings; maximum values.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Short circuit protection; dual element fuses... Trailing Cables § 75.601-3 Short circuit protection; dual element fuses; current ratings; maximum values. Dual element fuses having adequate current-interrupting capacity shall meet the requirements for short...

  15. Anthracene-fused BODIPYs as near-infrared dyes with high photostability

    KAUST Repository

    Zeng, Lintao; Jiao, Chongjun; Huang, Xiaobo; Huang, Kuo-Wei; Chin, Weeshong; Wu, Jishan

    2011-01-01

    An anthracene unit was successfully fused to the zigzag edge of a boron dipyrromethene (BODIPY) core by an FeCl 3-mediated oxidative cyclodehydrogenation reaction. Meanwhile, a dimer was also formed by both intramolecular cyclization and intermolecular coupling. The anthracene-fused BODIPY monomer 7a and dimer 7b showed small energy gaps (∼1.4 eV) and near-infrared absorption/emission. Moreover, they exhibited high photostability. © 2011 American Chemical Society.

  16. Anthracene-fused BODIPYs as near-infrared dyes with high photostability

    KAUST Repository

    Zeng, Lintao

    2011-11-18

    An anthracene unit was successfully fused to the zigzag edge of a boron dipyrromethene (BODIPY) core by an FeCl 3-mediated oxidative cyclodehydrogenation reaction. Meanwhile, a dimer was also formed by both intramolecular cyclization and intermolecular coupling. The anthracene-fused BODIPY monomer 7a and dimer 7b showed small energy gaps (∼1.4 eV) and near-infrared absorption/emission. Moreover, they exhibited high photostability. © 2011 American Chemical Society.

  17. 30 CFR 75.601-2 - Short circuit protection; use of fuses; approval by the Secretary.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Short circuit protection; use of fuses... Trailing Cables § 75.601-2 Short circuit protection; use of fuses; approval by the Secretary. Fuses shall not be employed to provide short circuit protection for trailing cables unless specifically approved...

  18. Crossed fused renal ectopia: Challenges in diagnosis and management

    Directory of Open Access Journals (Sweden)

    Shailesh Solanki

    2013-01-01

    Full Text Available Aim: Crossed fused renal ectopia is a rare congenital malformation, which is reported to be usually asymptomatic but may have varied presentations. This survey was conducted to study the clinical profile and the challenges posed in the management of this entity. Materials and Methods: Retrospective analysis of 6 patients diagnosed to have crossed fused renal ectopia during 1997-2010. The diagnosis was confirmed during surgical exploration in one patient. In one patient it was detected on antenatal ultrasonography and in the other 4 patients it was detected during investigations for abdominal pain, abdominal mass, anorectal malformation and urinary tract infection. Results: The left moiety was crossed and fused with the right moiety in 4 cases. Ultrasonography was found to be a good screening investigation with useful diagnostic contributions from CT scans, radionuclide scintigraphy and magnetic resonance urography. Micturating cystourethrography revealed presence of VUR in 4 cases, 3 of whom have undergone ureteric reimplantation. Two patients required pyeloplasty for pelviureteric junction obstruction; in one of these patients the upper ureter was entrapped in the isthmus. In one patient, a non-functioning moiety resulted in nephrectomy. All children were asymptomatic at last follow-up with stable renal functions. Conclusions: Crossed fused renal ectopia was detected in most patients during investigation for other problems. It was found more commonly in boys. The left moiety was crossed to the right in the majority of cases. Associated urological problems were found in most cases and required the appropriate surgical management.

  19. Material Considerations for Fused-Filament Fabrication of Solid Dosage Forms

    Directory of Open Access Journals (Sweden)

    Evert Fuenmayor

    2018-04-01

    Full Text Available Material choice is a fundamental consideration when it comes to designing a solid dosage form. The matrix material will ultimately determine the rate of drug release since the physical properties (solubility, viscosity, and more of the material control both fluid ingress and disintegration of the dosage form. The bulk properties (powder flow, concentration, and more of the material should also be considered since these properties will influence the ability of the material to be successfully manufactured. Furthermore, there is a limited number of approved materials for the production of solid dosage forms. The present study details the complications that can arise when adopting pharmaceutical grade polymers for fused-filament fabrication in the production of oral tablets. The paper also presents ways to overcome each issue. Fused-filament fabrication is a hot-melt extrusion-based 3D printing process. The paper describes the problems encountered in fused-filament fabrication with Kollidon® VA64, which is a material that has previously been utilized in direct compression and hot-melt extrusion processes. Formulation and melt-blending strategies were employed to increase the printability of the material. The paper defines for the first time the essential parameter profile required for successful 3D printing and lists several pre-screening tools that should be employed to guide future material formulation for the fused-filament fabrication of solid dosage forms.

  20. High-Speed Fuses in IGBT based Voltage Source Converters

    DEFF Research Database (Denmark)

    Iov, Florin; Blaabjerg, Frede; Rasmussen, Henrik

    2005-01-01

    The demand for protection of power electronic applications has during the last couple of years increased regarding the high-power IGBT modules. Even with an active protection, a high power IGBT still has a risk of exhibiting a violent rupture in the case of a fault if IGBT fuses do not protect it...... protection. First, the problem of adding inductance in the DC-link circuit is treated, second a short discussion of the protection of the IGBT module is done, and finally, the impact of the high frequency loading on the current carrying capability of the fuses is presented....

  1. Modelling and Analysis of Proximity Effect in IGBT Fuses

    DEFF Research Database (Denmark)

    Iov, Florin; Blaabjerg, Frede; Rasmussen, Henrik

    2005-01-01

    The demand for protection of power electronic applications has during the last couple of years increased regarding the high-power IGBT modules. The consequences of electrical faults can be severe in special cases; not only on the equipment but also to people, if safety principles are not applied....... Even with an active protection, a high power IGBT still has a risk of exhibiting a violent rupture in the case of a fault if e.g. IGBT fuses are not protecting it. By introducing fuses into voltage source converters a better protection of IGBT's can be achieved. However, skin and proximity effects...

  2. Sequential Multicomponent Strategy for the Diastereoselective Synthesis of Densely Functionalized Spirooxindole-Fused Thiazolidines

    NARCIS (Netherlands)

    Rainoldi, Giulia; Begnini, Fabio; De Munnik, Mariska; Lo Presti, Leonardo; Vande Velde, Christophe M.L.; Orru, Romano; Lesma, Giordano; Ruijter, Eelco; Silvani, Alessandra

    2018-01-01

    We developed two Ugi-type three-component reactions of spirooxindole-fused 3-thiazolines, isocyanides, and either carboxylic acids or trimethylsilyl azide, to give highly functionalized spirooxindole-fused thiazolidines. Two diverse libraries were generated using practical and robust procedures

  3. Recycling potential for low voltage and high voltage high rupturing capacity fuse links.

    Science.gov (United States)

    Psomopoulos, Constantinos S; Barkas, Dimitrios A; Kaminaris, Stavros D; Ioannidis, George C; Karagiannopoulos, Panagiotis

    2017-12-01

    Low voltage and high voltage high-rupturing-capacity fuse links are used in LV and HV installations respectively, protecting mainly the LV and HV electricity distribution and transportation networks. The Waste Electrical and Electronic Equipment Directive (2002/96/EC) for "Waste of electrical and electronic equipment" is the main related legislation and as it concerns electrical and electronic equipment, it includes electric fuses. Although, the fuse links consist of recyclable materials, only small scale actions have been implemented for their recycling around Europe. This work presents the possibilities for material recovery from this specialized industrial waste for which there are only limited volume data. Furthermore, in order to present the huge possibilities and environmental benefits, it presents the potential for recycling of HRC fuses used by the Public Power Corporation of Greece, which is the major consumer for the country, but one of the smallest ones in Europe and globally, emphasizing in this way in the issue. According to the obtained results, fuse recycling could contribute to the effort for minimize the impacts on the environment through materials recovery and reduction of the wastes' volume disposed of in landfills. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Enhancement of laser induced damage threshold of fused silica by acid etching combined with UV laser conditioning

    International Nuclear Information System (INIS)

    Chen Meng; Xiang Xia; Jiang Yong; Zu Xiaotao; Yuan Xiaodong; Zheng Wanguo; Wang Haijun; Li Xibin; Lu Haibing; Jiang Xiaodong; Wang Chengcheng

    2010-01-01

    Acid etching combined with UV laser conditioning is developed to enhance the laser induced damage threshold (LIDT) of fused silica. Firstly, the fused silica is etched for 1 ∼ 100 min with a buffered 1% HF solution. After acid etching, its transmittance, surface roughness and LIDT are measured. The results reveal that the fused silica has the highest LIDT and transmittance after etching for 10 min. Then UV laser (355 nm) conditioning is adopted to process the 10-min-etched fused silica. When the laser fluence is below 60% of fused silica's zero probability damage threshold, the LIDT increases gradually with the increase of laser conditioning fluence. However, the LIDT rapidly decreases to be lower than the threshold of the 10-min-etched fused silica when the conditioning fluence is up to 80% of the threshold. Proper acid etching and laser conditioning parameters will effectively enhance the laser damage resistance of fused silica. (authors)

  5. Combined Kernel-Based BDT-SMO Classification of Hyperspectral Fused Images

    Directory of Open Access Journals (Sweden)

    Fenghua Huang

    2014-01-01

    Full Text Available To solve the poor generalization and flexibility problems that single kernel SVM classifiers have while classifying combined spectral and spatial features, this paper proposed a solution to improve the classification accuracy and efficiency of hyperspectral fused images: (1 different radial basis kernel functions (RBFs are employed for spectral and textural features, and a new combined radial basis kernel function (CRBF is proposed by combining them in a weighted manner; (2 the binary decision tree-based multiclass SMO (BDT-SMO is used in the classification of hyperspectral fused images; (3 experiments are carried out, where the single radial basis function- (SRBF- based BDT-SMO classifier and the CRBF-based BDT-SMO classifier are used, respectively, to classify the land usages of hyperspectral fused images, and genetic algorithms (GA are used to optimize the kernel parameters of the classifiers. The results show that, compared with SRBF, CRBF-based BDT-SMO classifiers display greater classification accuracy and efficiency.

  6. Search for stress dependence in the internal friction of fused silica

    International Nuclear Information System (INIS)

    Willems, Phil; Lamb, Corinne; Heptonstall, Alastair; Hough, Jim

    2003-01-01

    The quality factor (Q) of the vertical bounce mode of a fused silica fiber pendulum is measured at high and low stresses. The internal friction of fused silica fibers is found to be independent of stress from 12.8 to 213 MPa at a level of 1.6x10 -8 . Comparison with Q's of fiber bending modes is consistent with losses concentrated in the surface of the fiber

  7. High strength fused silica flexures manufactured by femtosecond laser

    Science.gov (United States)

    Bellouard, Yves; Said, Ali A.; Dugan, Mark; Bado, Philippe

    2009-02-01

    Flexures are mechanical elements used in micro- and precision-engineering to precisely guide the motion of micro-parts. They consist of slender bodies that deform elastically upon the application of a force. Although counter-intuitive at first, fused silica is an attractive material for flexure. Pending that the machining process does not introduce surface flaws that would lead to catastrophic failure, the material has a theoretically high ultimate tensile strength of several GPa. We report on high-aspect ratio fused silica flexures manufactured by femtosecond laser combined with chemical etching. Notch-hinges with thickness as small as twenty microns and aspect ratios comparable to aspect ratios obtained by Deep- Reactive-Ion-Etching (DRIE) were fabricated and tested under different loading conditions. Multiple fracture tests were performed for various loading conditions and the cracks morphologies were analyzed using Scanning Electron Microscopy. The manufactured elements show outstanding mechanical properties with flexural strengths largely exceeding those obtained with other technologies and materials. Fused silica flexures offer a mean to combine integrated optics with micro-mechanics in a single monolithic substrate. Waveguides and mechanical elements can be combined in a monolithic devices opening new opportunities for integrated opto-mechatronics devices.

  8. Comparing monolithic and fused core HPLC columns for fast chromatographic analysis of fat-soluble vitamins.

    Science.gov (United States)

    Kurdi, Said El; Muaileq, Dina Abu; Alhazmi, Hassan A; Bratty, Mohammed Al; Deeb, Sami El

    2017-06-27

    HPLC stationary phases of monolithic and fused core type can be used to achieve fast chromatographic separation as an alternative to UPLC. In this study, monolithic and fused core stationary phases are compared for fast separation of four fat-soluble vitamins. Three new methods on the first and second generation monolithic silica RP-18e columns and a fused core pentafluoro-phenyl propyl column were developed. Application of three fused core columns offered comparable separations of retinyl palmitate, DL-α-tocopheryl acetate, cholecalciferol and menadione in terms of elution speed and separation efficiency. Separation was achieved in approx. 5 min with good resolution (Rs > 5) and precision (RSD ≤ 0.6 %). Monolithic columns showed, however, a higher number of theoretical plates, better precision and lower column backpressure than the fused core column. The three developed methods were successfully applied to separate and quantitate fat-soluble vitamins in commercial products.

  9. FUSE: a profit maximization approach for functional summarization of biological networks.

    Science.gov (United States)

    Seah, Boon-Siew; Bhowmick, Sourav S; Dewey, C Forbes; Yu, Hanry

    2012-03-21

    The availability of large-scale curated protein interaction datasets has given rise to the opportunity to investigate higher level organization and modularity within the protein interaction network (PPI) using graph theoretic analysis. Despite the recent progress, systems level analysis of PPIS remains a daunting task as it is challenging to make sense out of the deluge of high-dimensional interaction data. Specifically, techniques that automatically abstract and summarize PPIS at multiple resolutions to provide high level views of its functional landscape are still lacking. We present a novel data-driven and generic algorithm called FUSE (Functional Summary Generator) that generates functional maps of a PPI at different levels of organization, from broad process-process level interactions to in-depth complex-complex level interactions, through a pro t maximization approach that exploits Minimum Description Length (MDL) principle to maximize information gain of the summary graph while satisfying the level of detail constraint. We evaluate the performance of FUSE on several real-world PPIS. We also compare FUSE to state-of-the-art graph clustering methods with GO term enrichment by constructing the biological process landscape of the PPIS. Using AD network as our case study, we further demonstrate the ability of FUSE to quickly summarize the network and identify many different processes and complexes that regulate it. Finally, we study the higher-order connectivity of the human PPI. By simultaneously evaluating interaction and annotation data, FUSE abstracts higher-order interaction maps by reducing the details of the underlying PPI to form a functional summary graph of interconnected functional clusters. Our results demonstrate its effectiveness and superiority over state-of-the-art graph clustering methods with GO term enrichment.

  10. Dictionary-Based Image Denoising by Fused-Lasso Atom Selection

    Directory of Open Access Journals (Sweden)

    Ao Li

    2014-01-01

    Full Text Available We proposed an efficient image denoising scheme by fused lasso with dictionary learning. The scheme has two important contributions. The first one is that we learned the patch-based adaptive dictionary by principal component analysis (PCA with clustering the image into many subsets, which can better preserve the local geometric structure. The second one is that we coded the patches in each subset by fused lasso with the clustering learned dictionary and proposed an iterative Split Bregman to solve it rapidly. We present the capabilities with several experiments. The results show that the proposed scheme is competitive to some excellent denoising algorithms.

  11. Overcurrent protection of transformers. Part 2: Traditional and new fusing philosophies for small and large transformers

    Energy Technology Data Exchange (ETDEWEB)

    Cook, C. J.; Niemira, J. K.

    2003-07-01

    New and traditional fusing philosophies for protecting transformers are discussed. This second in a two-part paper covers selection criteria for a transformer-primary fuse to protect the transformer consistent with industry-accepted through-fault protection curves. Also covered are the principles of coordination as they relate to the proper selection of the primary-side fuse and power fuses and the principles underlying the protection of load-side conductors and cables. The critical nature of secondary fault protection on small three-phase transformers used on industrial, commercial, and institutional power systems, as well as small-to-medium size three-phase power transformers used in utility substations is emphasized, in view of the long lead time and expense involved in replacing these transformers. In contrast, no special protection recommendations are made for small-kVA overhead distribution transformers, since they are not considered likely to experience secondary faults, and the rare faults that do occur will not likely be detected and cleared by the primary fuse. Also of importance is the fact that these transformers are inexpensive and readily available. Overall, large fuse rating, used in combination with a tank-mounted surge arrester is recommended, because it can provide better transformer protection than the smaller fuse ratings traditionally employed. 4 refs., 2 tabs., 4 figs.

  12. Crossed fused renal ectopia in a Persian cat

    Directory of Open Access Journals (Sweden)

    Sang-Hyuk Seo

    2017-03-01

    Full Text Available Case summary This report describes a rare case of crossed fused renal ectopia (CFRE in a cat. A mature intact male Persian cat presented with bloody nasal discharge and ascites. Diagnostic studies revealed an ectopic left kidney fused with an orthotopic right kidney and a concurrent feline infectious peritonitis (FIP infection. The FIP was responsible for clinical signs in this cat, while clinical signs associated with CFRE were not obvious. Despite receiving intensive treatment, the cat died. A post-mortem examination was not performed because the owners declined approval. Relevance and novel information To the best of our knowledge, this is the first report of L-shaped CFRE in a cat. In addition, this report describes the CT features of L-shaped CFRE in a cat.

  13. Diagnosis and staging of breast cancer by SPECT images fused with CT images

    International Nuclear Information System (INIS)

    Li Yanjing; Zhu Qiaomei

    2007-01-01

    Objective: To evaluate the TNM staging value of 99mTc-MIBI scintimammotraphy with SPECT-CT images fusing for the diagnosis of breast cancer. Methods: 10 patients with breast cancer underwent scintimammography with 99mTc-MIBI, and SPECT images were fused with CT images. Images were compared with final diagnosis confirmed by histopathology. Results: Of the 19 breast cancer patients, one case of invasive ductal carcinoma showed false-negative. Among 18 cases of positive lesions, axillary metastases were involved in 10, supraclavicular nodes were also defined in 3, para-sternum nodes were involved in 2, 2 were missed and 1 cases without metastatic node. The axillary lymph nodes were divided into three levels with respect to their position relative to the pectoralis minor muscle by fused images. Conclusion: 99mTc-MIBI scintimammotraphy combined with SPECT-CT images fusing is of some clinical value in TNM staging of breast cancer. (authors)

  14. Bulk damage and absorption in fused silica due to high-power laser applications

    Science.gov (United States)

    Nürnberg, F.; Kühn, B.; Langner, A.; Altwein, M.; Schötz, G.; Takke, R.; Thomas, S.; Vydra, J.

    2015-11-01

    Laser fusion projects are heading for IR optics with high broadband transmission, high shock and temperature resistance, long laser durability, and best purity. For this application, fused silica is an excellent choice. The energy density threshold on IR laser optics is mainly influenced by the purity and homogeneity of the fused silica. The absorption behavior regarding the hydroxyl content was studied for various synthetic fused silica grades. The main absorption influenced by OH vibrational excitation leads to different IR attenuations for OH-rich and low-OH fused silica. Industrial laser systems aim for the maximum energy extraction possible. Heraeus Quarzglas developed an Yb-doped fused silica fiber to support this growing market. But the performance of laser welding and cutting systems is fundamentally limited by beam quality and stability of focus. Since absorption in the optical components of optical systems has a detrimental effect on the laser focus shift, the beam energy loss and the resulting heating has to be minimized both in the bulk materials and at the coated surfaces. In collaboration with a laser research institute, an optical finisher and end users, photo thermal absorption measurements on coated samples of different fused silica grades were performed to investigate the influence of basic material properties on the absorption level. High purity, synthetic fused silica is as well the material of choice for optical components designed for DUV applications (wavelength range 160 nm - 260 nm). For higher light intensities, e.g. provided by Excimer lasers, UV photons may generate defect centers that effect the optical properties during usage, resulting in an aging of the optical components (UV radiation damage). Powerful Excimer lasers require optical materials that can withstand photon energy close to the band gap and the high intensity of the short pulse length. The UV transmission loss is restricted to the DUV wavelength range below 300 nm and

  15. Comparing monolithic and fused core HPLC columns for fast chromatographic analysis of fat-soluble vitamins

    Directory of Open Access Journals (Sweden)

    Kurdi Said El

    2017-06-01

    Full Text Available HPLC stationary phases of monolithic and fused core type can be used to achieve fast chromatographic separation as an alternative to UPLC. In this study, monolithic and fused core stationary phases are compared for fast separation of four fat-soluble vitamins. Three new methods on the first and second generation monolithic silica RP-18e columns and a fused core pentafluoro-phenyl propyl column were developed. Application of three fused core columns offered comparable separations of retinyl palmitate, DL-α-tocopheryl acetate, cholecalciferol and menadione in terms of elution speed and separation efficiency. Separation was achieved in approx. 5 min with good resolution (Rs > 5 and precision (RSD ≤ 0.6 %. Monolithic columns showed, however, a higher number of theoretical plates, better precision and lower column backpressure than the fused core column. The three developed methods were successfully applied to separate and quantitate fat-soluble vitamins in commercial products.

  16. Thermodynamic perturbation theory for fused hard-sphere and hard-disk chain fluids

    International Nuclear Information System (INIS)

    Zhou, Y.; Hall, C.K.; Stell, G.

    1995-01-01

    We find that first-order thermodynamic perturbation theory (TPT1) which incorporates the reference monomer fluid used in the generalized Flory--AB (GF--AB) theory yields an equation of state for fused hard-sphere (FHS) chain fluids that has accuracy comparable to the GF--AB and GF--dimer--AC theories. The new TPT1 equation of state is significantly more accurate than other extensions of the TPT1 theory to FHS chain fluids. The TPT1 is also extended to two-dimensional fused hard-disk chain fluids. For the fused hard-disk dimer fluid, the extended TPT1 equation of state is found to be more accurate than the Boublik hard-disk dimer equation of state. copyright 1995 American Institute of Physics

  17. FUSE: a profit maximization approach for functional summarization of biological networks

    Directory of Open Access Journals (Sweden)

    Seah Boon-Siew

    2012-03-01

    Full Text Available Abstract Background The availability of large-scale curated protein interaction datasets has given rise to the opportunity to investigate higher level organization and modularity within the protein interaction network (PPI using graph theoretic analysis. Despite the recent progress, systems level analysis of PPIS remains a daunting task as it is challenging to make sense out of the deluge of high-dimensional interaction data. Specifically, techniques that automatically abstract and summarize PPIS at multiple resolutions to provide high level views of its functional landscape are still lacking. We present a novel data-driven and generic algorithm called FUSE (Functional Summary Generator that generates functional maps of a PPI at different levels of organization, from broad process-process level interactions to in-depth complex-complex level interactions, through a pro t maximization approach that exploits Minimum Description Length (MDL principle to maximize information gain of the summary graph while satisfying the level of detail constraint. Results We evaluate the performance of FUSE on several real-world PPIS. We also compare FUSE to state-of-the-art graph clustering methods with GO term enrichment by constructing the biological process landscape of the PPIS. Using AD network as our case study, we further demonstrate the ability of FUSE to quickly summarize the network and identify many different processes and complexes that regulate it. Finally, we study the higher-order connectivity of the human PPI. Conclusion By simultaneously evaluating interaction and annotation data, FUSE abstracts higher-order interaction maps by reducing the details of the underlying PPI to form a functional summary graph of interconnected functional clusters. Our results demonstrate its effectiveness and superiority over state-of-the-art graph clustering methods with GO term enrichment.

  18. A hierarachical data structure representation for fusing multisensor information

    Energy Technology Data Exchange (ETDEWEB)

    Maren, A.J. [Tennessee Univ., Tullahoma, TN (United States). Space Inst.; Pap, R.M.; Harston, C.T. [Accurate Automation Corp., Chattanooga, TN (United States)

    1989-12-31

    A major problem with MultiSensor Information Fusion (MSIF) is establishing the level of processing at which information should be fused. Current methodologies, whether based on fusion at the data element, segment/feature, or symbolic levels, are each inadequate for robust MSIF. Data-element fusion has problems with coregistration. Attempts to fuse information using the features of segmented data relies on a Presumed similarity between the segmentation characteristics of each data stream. Symbolic-level fusion requires too much advance processing (including object identification) to be useful. MSIF systems need to operate in real-time, must perform fusion using a variety of sensor types, and should be effective across a wide range of operating conditions or deployment environments. We address this problem through developing a new representation level which facilitates matching and information fusion. The Hierarchical Data Structure (HDS) representation, created using a multilayer, cooperative/competitive neural network, meets this need. The HDS is an intermediate representation between the raw or smoothed data stream and symbolic interpretation of the data. it represents the structural organization of the data. Fused HDSs will incorporate information from multiple sensors. Their knowledge-rich structure aids top-down scene interpretation via both model matching and knowledge-based region interpretation.

  19. A hierarachical data structure representation for fusing multisensor information

    Energy Technology Data Exchange (ETDEWEB)

    Maren, A.J. (Tennessee Univ., Tullahoma, TN (United States). Space Inst.); Pap, R.M.; Harston, C.T. (Accurate Automation Corp., Chattanooga, TN (United States))

    1989-01-01

    A major problem with MultiSensor Information Fusion (MSIF) is establishing the level of processing at which information should be fused. Current methodologies, whether based on fusion at the data element, segment/feature, or symbolic levels, are each inadequate for robust MSIF. Data-element fusion has problems with coregistration. Attempts to fuse information using the features of segmented data relies on a Presumed similarity between the segmentation characteristics of each data stream. Symbolic-level fusion requires too much advance processing (including object identification) to be useful. MSIF systems need to operate in real-time, must perform fusion using a variety of sensor types, and should be effective across a wide range of operating conditions or deployment environments. We address this problem through developing a new representation level which facilitates matching and information fusion. The Hierarchical Data Structure (HDS) representation, created using a multilayer, cooperative/competitive neural network, meets this need. The HDS is an intermediate representation between the raw or smoothed data stream and symbolic interpretation of the data. it represents the structural organization of the data. Fused HDSs will incorporate information from multiple sensors. Their knowledge-rich structure aids top-down scene interpretation via both model matching and knowledge-based region interpretation.

  20. Toxicity of inhaled 144Ce fused clay particles in beagle dogs. VII

    International Nuclear Information System (INIS)

    Hahn, F.F.; Boecker, B.B.; Hobbs, C.H.; Jones, R.K.; Mauderly, J.L.; McClellan, R.O.; Pickrell, J.A.

    1974-01-01

    The metabolism, dosimetry, and effects of inhaled 144 Ce in fused clay particles are being investigated in the Beagle dog to aid in assessing the biological consequences of release of 144 Ce in a relatively insoluble form such as might occur in certain types of nuclear accidents. The toxicity of inhaled 144 Ce fused clay is also of general interest since it is representative of intermediate-lived beta-emitting radionuclides. Two major studies with young adult dogs (12 to 14 months of age at exposure) are involved: (1) a metabolism and dosimetry study in which 24 dogs were serially sacrificed over an extended period of time, and (2) a longevity study with 2 series of dogs; Series I with 15 dogs exposed to aerosols of 144 Ce in fused clay particles to yield initial lung burdens of 11 to 210 μCi/kg body weight and 3 control dogs exposed to nonradioactive fused clay particles and Series II with 96 dogs exposed to aerosols of 144 Ce in fused clay particles to yield initial lung burdens of 0.0024 to 66 μCi/kg body weight and 12 control dogs exposed to nonradioactive fused clay particles. Twenty-eight dogs died or were euthanized at 143 to 2396 days after inhalation of 144 Ce. The prominent findings were radiation pneumonitis in 17 dogs that died or were euthanized at early time periods and neoplastic disease in 10 of the 11 dogs that died or were euthanized at 750 days or later; 5 with hemangiosarcoma of the lung, 1 with both a hemangiosarcoma and a fibrosarcoma of the lung, 1 with both a bronchiolo-alveolar carcinoma and a hemangiosarcoma of lung, 1 with a hemangiosarcoma of lung, bronchiolo-alveolar carcinoma, and a bronchiogenic adenocarcinoma, and 1 each with a hemangiosarcoma of the mediastinum and of the spleen. The cumulative radiation dose to the lung at time of death has ranged from 22,000 to 140,000 rads. Serial observations are continuing on the 83 survivors and 15 controls. (U.S.)

  1. Three-port beam splitter of a binary fused-silica grating.

    Science.gov (United States)

    Feng, Jijun; Zhou, Changhe; Wang, Bo; Zheng, Jiangjun; Jia, Wei; Cao, Hongchao; Lv, Peng

    2008-12-10

    A deep-etched polarization-independent binary fused-silica phase grating as a three-port beam splitter is designed and manufactured. The grating profile is optimized by use of the rigorous coupled-wave analysis around the 785 nm wavelength. The physical explanation of the grating is illustrated by the modal method. Simple analytical expressions of the diffraction efficiencies and modal guidelines for the three-port beam splitter grating design are given. Holographic recording technology and inductively coupled plasma etching are used to manufacture the fused-silica grating. Experimental results are in good agreement with the theoretical values.

  2. Cavity Formation Modeling of Fiber Fuse in Single-Mode Optical Fibers

    Directory of Open Access Journals (Sweden)

    Yoshito Shuto

    2017-01-01

    Full Text Available The evolution of a fiber-fuse phenomenon in a single-mode optical fiber was studied theoretically. To clarify both the silica-glass densification and cavity formation, which have been observed in fiber fuse propagation, we investigated a nonlinear oscillation model using the Van Der Pol equation. This model was able to phenomenologically explain both the densification of the core material and the formation of periodic cavities in the core layer as a result of a relaxation oscillation.

  3. Fusing Intelligence With Law Enforcement Information: An Analytic Imperative

    National Research Council Canada - National Science Library

    Thornlow, Christopher C

    2005-01-01

    ... and Law Enforcement Communities to fuse and analyze foreign threat intelligence with domestic law enforcement information in a timely fashion to provide adequate indications and warning of such an...

  4. New developments in fused deposition modeling of ceramics

    DEFF Research Database (Denmark)

    Bellini, Anna; Shor, L.; Guceri, S.I.

    2005-01-01

    Purpose - To shift from rapid prototyping (RP) to agile fabrication by broadening the material selection, e.g. using ceramics, hence improving the properties (e.g. mechanical properties) of fused deposition modeling (FDM) products. Design/methodology/approach - This paper presents the development...

  5. A comparative clinical, pathological, biochemical and genetic study of fused in sarcoma proteinopathies

    DEFF Research Database (Denmark)

    Lashley, Tammaryn; Rohrer, Jonathan D; Bandopadhyay, Rina

    2011-01-01

    Neuronal intermediate filament inclusion disease and atypical frontotemporal lobar degeneration are rare diseases characterized by ubiquitin-positive inclusions lacking transactive response DNA-binding protein-43 and tau. Recently, mutations in the fused in sarcoma gene have been shown to cause...... findings, as well as genetic and biochemical data in 14 fused in sarcoma proteinopathy cases. In this cohort, the age of onset was variable but included cases of young-onset disease. Patients with atypical frontotemporal lobar degeneration with ubiquitinated inclusions all presented with behavioural...... familial amyotrophic lateral sclerosis and fused in sarcoma-positive neuronal inclusions have subsequently been demonstrated in neuronal intermediate filament inclusion disease and atypical frontotemporal lobar degeneration with ubiquitinated inclusions. Here we provide clinical, imaging, morphological...

  6. Benign versus malignant osseous lesions in spine: differentiation by means of bone SPECT/CT fused image

    International Nuclear Information System (INIS)

    Yao Zhiming; Qu Wanying

    2004-01-01

    This study compared the efficiency of SPECT-CT fused image with planar bone scan, bone SPECT and CT in differentiating malignant from benign lesions and detecting metastases to the spine. Methods. Total 144 patients with spinal lesions underwent planar bone scan (WB), single photon tomography (SPECT), CT and SPECT-CT fused image by a SPECT/CT system. The malignant or benign nature of lesions was proved by radiological Methods, histological findings, 6-24 month follow-up, or all of these. The diagnostic results was divided into 4 types, i.e., normal, benign, doubtful malignant and malignant. Results. There were 137 malignant and 252 benign lesions in 144 patients, respectively. The percentages of doubtful malignant diagnosed by WB, SPECT, CT and fused image are 22.6%, 5.1%, 9.5% and 0%, respectively, p < 0.01-0.001, except for the comparison between the percentages of SPECT and CT. Sensitivities in detection of malignant lesions by WB, SPECT, CT and fused image are 75.2%, 94.2%, 96.6% and 99.3%, respectively, P < 0.001, excepting for the comparisons between those of SPECT and CT, and between those of CT and fused image. The sensitivities m detection of benign lesions by WB, SPECT, CT and fused image are, 56.7%, 86.5%, 90.1% and 96.8%, respectively, P < 0.005 - 0.001, excepting for the comparison between those of SPECT and CT. The specificities in detection of maliganant lesions by WB, SPECT, CT and fused image are 70.6%, 88.9%, 97.2% and 97.6%, respectively, P < 0.001, excepting for the comparison between those of CT and fused image. Conclusion. Bone SPECT-CT fused image has highest diagnostic and differentiating diagnostic values in detection of spinal abnormalities over the planar bone scanning and SPECT. The CT by present SPECT/CT system can complement planar bone scanning and SPECT and is clinically valuable in detection of spinal abnormalities. (authors)

  7. A system for the non-destructive detection of faults in safety fuses using radioisotopes

    International Nuclear Information System (INIS)

    Goncalves, D.

    1980-01-01

    Design of an equipment for on line detection of faults in the safety fuses for conventional explosives employing transmission of #betta#-radiation is reported. The faults are detected by an ion-chamber based on the variation of the intensity of the beta particles transmitted through the fuse during its passage across the collimated beam. Strontium-90 encapsulated in stainless steel or aluminum is used as the #betta#-source. An electrical signal corresponding the fault is obtained by subtraction of an external current, that is equivalent to the output of the ion-chamber in the presence of faultless fuse. (Author) [pt

  8. HVI Ballistic Limit Charaterization of Fused Silica Thermal Pane

    Science.gov (United States)

    Bohl, William E.; Miller, Joshua E.; Christiansen, Eric L.; Deighton, Kevin.; Davis, Bruce

    2015-01-01

    The Orion spacecraft's windows are exposed to the micrometeroid and orbital debris (MMOD) space environments while in space as well as the Earth entry environment at the mission's conclusion. The need for a low-mass spacecraft window design drives the need to reduce conservatism when assessing the design for loss of crew due to MMOD impact and subsequent Earth entry. Therefore, work is underway at NASA and Lockheed Martin to improve characterization of the complete penetration ballistic limit of an outer fused silica thermal pane. Hypervelocity impact tests of the window configuration at up to 10 km/s and hydrocode modeling have been performed with a variety of projectile materials to enable refinement of the fused silica ballistic limit equation.

  9. [XPS analysis of beads formed by fuse breaking of electric copper wire].

    Science.gov (United States)

    Wu, Ying; Meng, Qing-Shan; Wang, Xin-Ming; Gao, Wei; Di, Man

    2010-05-01

    The in-depth composition of beads formed by fuse breaking of the electric copper wire in different circumstances was studied by XPS with Ar+ ion sputtering. In addition, the measured Auger spectra and the calculated Auger parameters were compared for differentiation of the substances of Cu and Cu2O. Corresponding to the sputtering depth, the molten product on a bead induced directly by fuse breaking of the copper wire without cover may be distinguished as three portions: surface layer with a drastic decrease in carbon content; intermediate layer with a gentle change in oxygen content and gradually diminished carbon peak, and consisting of Cu2O; transition layer without Cu2O and with a rapid decrease in oxygen content. While the molten product on a bead formed by fuse breaking of the copper wire after its insulating cover had been burned out may be distinguished as two portions: surface layer with carbon content decreasing quickly; subsurface layer without Cu2O and with carbon and oxygen content decreasing gradually. Thus, it can be seen that there was an obvious interface between the layered surface product and the substrate for the first type of bead, while as to the second type of bead there was no interface. As a result, the presence of Cu2O and the quantitative results can be used to identify the molten product on a bead induced directly by fuse breaking of the copper wire without cover and the molten product on a bead formed by fuse breaking of the cupper wire after its insulating cover had been burned out, as a complementary technique for the judgments of fire cause.

  10. SimFuse: A Novel Fusion Simulator for RNA Sequencing (RNA-Seq Data

    Directory of Open Access Journals (Sweden)

    Yuxiang Tan

    2015-01-01

    Full Text Available The performance evaluation of fusion detection algorithms from high-throughput sequencing data crucially relies on the availability of data with known positive and negative cases of gene rearrangements. The use of simulated data circumvents some shortcomings of real data by generation of an unlimited number of true and false positive events, and the consequent robust estimation of accuracy measures, such as precision and recall. Although a few simulated fusion datasets from RNA Sequencing (RNA-Seq are available, they are of limited sample size. This makes it difficult to systematically evaluate the performance of RNA-Seq based fusion-detection algorithms. Here, we present SimFuse to address this problem. SimFuse utilizes real sequencing data as the fusions’ background to closely approximate the distribution of reads from a real sequencing library and uses a reference genome as the template from which to simulate fusions’ supporting reads. To assess the supporting read-specific performance, SimFuse generates multiple datasets with various numbers of fusion supporting reads. Compared to an extant simulated dataset, SimFuse gives users control over the supporting read features and the sample size of the simulated library, based on which the performance metrics needed for the validation and comparison of alternative fusion-detection algorithms can be rigorously estimated.

  11. Electromigration driven failures on miniature silver fuses at the Large Hadron Collider

    CERN Document Server

    Trikoupis, Nikolaos; Perez Fontenla, Ana Teresa

    2017-01-01

    Spurious faults were observed on the miniature silver fuses of electronic cards used for the cryogenics instrumentation in the LHC (Large Hadron Collider) accelerator at CERN. By applying analytical tools and techniques such as Scanning Electron Microscopy, spectrometry and Weibull reliability calculations and by the knowledge of operating temperatures and operational time of each unit, the origin of the problem has now been understood and can be attributed to electromigration. The selected fuse was operated at moderate temperature and load conditions and was considered as a “lifetime” component. However, it turned out to have a smaller than expected MTTF with failures following a Weibull distribution of $\\beta = 3.91$ and $\\eta = 2323$. The literature describes extensively the effects of electromigration, but there are only limited references referring to the impact of this phenomenon on miniature silver fuses for electronic circuits.

  12. Fusion algebra and fusing matrices

    International Nuclear Information System (INIS)

    Gao Yihong; Li Miao; Yu Ming.

    1989-09-01

    We show that the Wilson line operators in topological field theories form a fusion algebra. In general, the fusion algebra is a relation among the fusing (F) matrices. In the case of the SU(2) WZW model, some special F matrix elements are found in this way, and the remaining F matrix elements are then determined up to a sign. In addition, the S(j) modular transformation of the one point blocks on the torus is worked out. Our results are found to agree with those obtained from the quantum group method. (author). 24 refs

  13. A vaccine strategy with multiple prostatic acid phosphatase-fused cytokines for prostate cancer treatment.

    Science.gov (United States)

    Fujio, Kei; Watanabe, Masami; Ueki, Hideo; Li, Shun-Ai; Kinoshita, Rie; Ochiai, Kazuhiko; Futami, Junichiro; Watanabe, Toyohiko; Nasu, Yasutomo; Kumon, Hiromi

    2015-04-01

    Immunotherapy is one of the attractive treatment strategies for advanced prostate cancer. The US Food and Drug Administration (FDA) previously approved the therapeutic vaccine, sipuleucel-T, which is composed of autologous antigen-presenting cells cultured with a fusion protein [prostatic acid phosphatase (PAP) and granulocyte-macrophage colony-stimulating factor (GMCSF)]. Although sipuleucel-T has been shown to prolong the median survival of patients for 4.1 months, more robust therapeutic effects may be expected by modifying the vaccination protocol. In the present study, we aimed to develop and validate a novel vaccination strategy using multiple PAP-fused cytokines for prostate cancer treatment. Using a super gene expression (SGE) system that we previously established to amplify the production of a recombinant protein, significant amounts of PAP-fused cytokines [human GMCSF, interleukin-2 (IL2), IL4, IL7 and mouse GMCSF and IL4] were obtained. We examined the activity of the fusion proteins in vitro to validate their cytokine functions. A significant upregulation of dendritic cell differentiation from monocytes was achieved by PAP-GMCSF when used with the other PAP-fused cytokines. The PAP-fused human IL2 significantly increased the proliferation of lymphocytes, as determined by flow cytometry. We also investigated the in vivo therapeutic effects of multiple PAP-fused cytokines in a mouse prostate cancer model bearing prostate-specific antigen (PSA)- and PAP-expressing tumors. The simultaneous intraperitoneal administration of PAP-GMCSF, -IL2, -IL4 and -IL7 significantly prevented tumor induction and inhibited the tumor growth in the PAP-expressing tumors, yet not in the PSA-expressing tumors. The in vivo therapeutic effects with the multiple PAP-fused cytokines were superior to the effects of PAP-GMCSF alone. We thus demonstrated the advantages of the combined use of multiple PAP-fused cytokines including PAP-GMCSF, and propose a promising prostatic

  14. Fiber fuse light-induced continuous breakdown of silica glass optical fiber

    CERN Document Server

    Todoroki, Shin-ichi

    2014-01-01

    This book describes the fiber fuse phenomenon that causes a serious problem for the present optical communication systems. High-power light often brings about catastrophic damage to optical devices. Silica glass optical fibers with ultralow transmission loss are not the exception. A fiber fuse appears in a heated region of the fiber cable delivering a few watts of light and runs toward the light source destroying its core region. Understanding this phenomenon is a necessary first step in the development of future optical communication systems. This book provides supplementary videos and photog

  15. High-voltage safety fuses for the transition-radiation tracking detector in the ATLAS experiment

    NARCIS (Netherlands)

    Voronov, SA; Voronov, YA; Onishchenko, EM; Simakov, AB; Sosnovtsev, VV; Suchkov, SI; Sugrobova, TA

    2004-01-01

    A safety fuse has been designed for the electrical protection of gas-filled detectors in the ATLAS experiment at CERN (Geneva, Switzerland). The fuse is a polished lithium niobate plate with a titanium strip of 91-kOmega resistance deposited by the photolithographic technique. The forced blow-out

  16. Helicopter Aircrew Training Using Fused Reality

    Science.gov (United States)

    2006-06-01

    PROCESS Blue screening involving human filming usually employs a blue or green backdrop, since skin contains little blue or green hue. These backdrops...Helicopter Aircrew Training Using Fused Reality 27 - 10 RTO-MP-HFM-136 a. b. c. d. e. f. Figure 13: Frames Showing Physical Object ( witch ... filming . However, when a user’s hands disrupt the light from a helmet-mounted light source, the shadows cast onto the distant background are diffuse and

  17. Electrolysis of uranium tetrafluorure fused salts

    International Nuclear Information System (INIS)

    Perillo, P.M.; Botbol, J.

    1991-01-01

    Electrolytic preparation of U has been unsuccessful because the metal formed is in easily oxidized state. Electrolytic depositions were made under various conditions from fused NaCl-KCl baths containing UF 4 . X-ray diffraction studies were made of the products. The results indicate that mixed U with several oxides phases are produced. It was concluded that the method was unlikely to be efficient for the production of U metal. (Author) [es

  18. Influence of radiation-dose pattern from inhaled beta--gamma-emitting radionuclides on canine peripheral lymphocytes

    International Nuclear Information System (INIS)

    Jones, R.K.; Boecker, B.B.; Pickrell, J.A.; Hobbs, C.H.; McClellan, R.O.

    1976-01-01

    As part of studies assess the biological hazards associated with inhaled radionuclides, periodic hematologic evaluations were performed on beagle dogs given a single nose-only exposure to aerosols of beta--gamma-emitting isotopes. The physical form and specific radionuclides selected produced radiation-dose patterns representative of those which might be encountered in the event of human accidental exposures. Dogs received graded lung burdens of either 90 Y, 91 Y, 144 Ce, or 90 Sr, each in fused clay. Differences in the effective half-lives of these radionuclides resulted in a spectrum of cumulative radiation doses to lung delivered at a variety of dose rates. Since the form in which the radionuclides were inhaled was relatively insoluble, the lung and intrathoracic tissues represented the primary recipient of the dose. Regardless of the effective half-life of radionuclide retention, a dose-related depression of peripheral lymphocytes was observed at various times after inhalation exposure. The time at which maximum depression and subsequent recovery occurred, however, was most directly related to the effective half-life of the radionuclide. Of special interest was the persistence of lymphopenia through 2 1 / 2 years after exposure to 144 Ce and 90 Sr in fused clay where, other than tracheobronchial lymph nodes, the lymphoid tissue received very little radiation dose. The possible mechanisms responsible for lymphocyte depression from these various radiation-dose patterns are discussed

  19. Vasculitic peripheral neuropathy

    Directory of Open Access Journals (Sweden)

    Mona Amini

    2014-02-01

    Full Text Available Primary systemic vasculitis in pre-capillary arteries is associated with peripheral neuropathy. In some types of systematic vasculitis about 60 % of patients have peripheral nervous system (PNS involvement. In vasculitic peripheral neuropathies (VPN a necrotizing and inflammatory process leads to narrowing of vasa nervorum lumen and eventually the appearance of ischemic lesions in peripheral nerves. Some features might be suggestive of VPN, like: axonal nerve degeneration, wallerian-like degeneration, and diameter irregularity of nerve. Peripheral nervous system (PNS destruction during systemic vasculitides should be considered, due to its frequency and early occurrence in vasculitis progression. The first line treatment of non systematic VPNs is corticosteroid agents, but these drugs might worsen the VPNs or systemic vasculitis.

  20. The effect of high-pressure devitrification and densification on ballistic-penetration resistance of fused silica

    Science.gov (United States)

    Avuthu, Vasudeva Reddy

    Despite the clear benefits offered by more advanced transparent materials, (e.g. transparent ceramics offer a very attractive combination of high stiffness and high hardness levels, highly-ductile transparent polymers provide superior fragment-containing capabilities, etc.), ballistic ceramic-glass like fused-silica remains an important constituent material in a majority of transparent impact-resistant structures (e.g. windshields and windows of military vehicles, portholes in ships, ground vehicles and spacecraft) used today. Among the main reasons for the wide-scale use of glass, the following three are most frequently cited: (i) glass-structure fabrication technologies enable the production of curved, large surface-area, transparent structures with thickness approaching several inches; (ii) relatively low material and manufacturing costs; and (iii) compositional modifications, chemical strengthening, and controlled crystallization have been demonstrated to be capable of significantly improving the ballistic properties of glass. In the present work, the potential of high-pressure devitrification and densification of fused-silica as a ballistic-resistance-enhancement mechanism is investigated computationally. In the first part of the present work, all-atom molecular-level computations are carried out to infer the dynamic response and material microstructure/topology changes of fused silica subjected to ballistic impact by a nanometer-sized hard projectile. The analysis was focused on the investigation of specific aspects of the dynamic response and of the microstructural changes such as the deformation of highly sheared and densified regions, and the conversion of amorphous fused silica to SiO2 crystalline allotropic modifications (in particular, alpha-quartz and stishovite). The microstructural changes in question were determined by carrying out a post-processing atom-coordination procedure. This procedure suggested the formation of high-density stishovite (and

  1. Simulation of the evolution of fused silica's surface defect during wet chemical etching

    Science.gov (United States)

    Liu, Taixiang; Yang, Ke; Li, Heyang; Yan, Lianghong; Yuan, Xiaodong; Yan, Hongwei

    2017-08-01

    Large high-power-laser facility is the basis for achieving inertial confinement fusion, one of whose missions is to make fusion energy usable in the near future. In the facility, fused silica optics plays an irreplaceable role to conduct extremely high-intensity laser to fusion capsule. But the surface defect of fused silica is a major obstacle limiting the output power of the large laser facility and likely resulting in the failure of ignition. To mitigate, or event to remove the surface defect, wet chemical etching has been developed as a practical way. However, how the surface defect evolves during wet chemical etching is still not clearly known so far. To address this problem, in this work, the three-dimensional model of surface defect is built and finite difference time domain (FDTD) method is developed to simulate the evolution of surface defect during etching. From the simulation, it is found that the surface defect will get smooth and result in the improvement of surface quality of fused silica after etching. Comparatively, surface defects (e.g. micro-crack, scratch, series of pinholes, etc.) of a typical fused silica at different etching time are experimentally measured. It can be seen that the simulation result agrees well with the result of experiment, indicating the FDTD method is valid for investigating the evolution of surface defect during etching. With the finding of FDTD simulation, one can optimize the treatment process of fused silica in practical etching or even to make the initial characterization of surface defect traceable.

  2. Research on non-destructive testing (NDT) aerospace igniter fuse with neutron radiography (NR)

    International Nuclear Information System (INIS)

    Mo Dawei; Liu Yisi; Cai Qingsheng; Chen Boxian

    1995-01-01

    The research works, facilities and results of NDT aerospace igniter fuse with neutron radiography at Tsinghua University swimming-pool reactor are introduced. The image quality (NR) of ASTM E545-85 I level was approached. The NR experimental research of the typical and possible defects was performed. The theoretical analysis was performed too. The feasibility of NDT aerospace igniter fuse with NR was proved experimentally

  3. Demonstrating Earth Connections and Fuses Working Together

    Science.gov (United States)

    Harrison, Mark

    2017-01-01

    Earth wires and fuses work together in UK mains circuits to keep users safe from electric shocks and are taught in many school contexts. The subject can be quite abstract and difficult for pupils to grasp, and a simple but visually clear and direct demonstration is described which would be easy for most physics departments to build and which can…

  4. Hemi-fused structure mediates and controls fusion and fission in live cells.

    Science.gov (United States)

    Zhao, Wei-Dong; Hamid, Edaeni; Shin, Wonchul; Wen, Peter J; Krystofiak, Evan S; Villarreal, Seth A; Chiang, Hsueh-Cheng; Kachar, Bechara; Wu, Ling-Gang

    2016-06-23

    Membrane fusion and fission are vital for eukaryotic life. For three decades, it has been proposed that fusion is mediated by fusion between the proximal leaflets of two bilayers (hemi-fusion) to produce a hemi-fused structure, followed by fusion between the distal leaflets, whereas fission is via hemi-fission, which also produces a hemi-fused structure, followed by full fission. This hypothesis remained unsupported owing to the lack of observation of hemi-fusion or hemi-fission in live cells. A competing fusion hypothesis involving protein-lined pore formation has also been proposed. Here we report the observation of a hemi-fused Ω-shaped structure in live neuroendocrine chromaffin cells and pancreatic β-cells, visualized using confocal and super-resolution stimulated emission depletion microscopy. This structure is generated from fusion pore opening or closure (fission) at the plasma membrane. Unexpectedly, the transition to full fusion or fission is determined by competition between fusion and calcium/dynamin-dependent fission mechanisms, and is notably slow (seconds to tens of seconds) in a substantial fraction of the events. These results provide key missing evidence in support of the hemi-fusion and hemi-fission hypothesis in live cells, and reveal the hemi-fused intermediate as a key structure controlling fusion and fission, as fusion and fission mechanisms compete to determine the transition to fusion or fission.

  5. Synthesis, reactivity, and properties of N-fused porphyrin rhenium(I) tricarbonyl complexes.

    Science.gov (United States)

    Toganoh, Motoki; Ikeda, Shinya; Furuta, Hiroyuki

    2007-11-12

    The thermal reactions of N-fused tetraarylporphyrins or N-confused tetraarylporphyrins with Re2(CO)10 gave the rhenium(I) tricarbonyl complexes bearing N-fused porphyrinato ligands (4) in moderate to good yields. The rhenium complexes 4 are characterized by mass, IR, 1H, and 13C NMR spectroscopy, and the structures of tetraphenylporphynato complex 4a and its nitro derivative 15 are determined by X-ray single crystal analysis. The rhenium complexes 4 show excellent stability against heat, light, acids, bases, and oxidants. The aromatic substitution reactions of 4 proceed without a loss of the center metal to give the nitro (15), formyl (16), benzoyl (17), and cyano derivatives (19), regioselectively. In the electrochemical measurements for 4, one reversible oxidation wave and two reversible reduction waves are observed. Their redox potentials imply narrow HOMO-LUMO band gaps of 4 and are consistent with their electronic absorption spectra, in which the absorption edges exceed 1000 nm. Theoretical study reveals that the HOMO and LUMO of the rhenium complexes are exclusively composed of the N-fused porphyrin skeleton. Protonation of 4 takes place at the 21-position regioselectively, reflecting the high coefficient of the C21 atom in the HOMO orbital. The skeletal rearrangement reaction from N-confused porphyrin Re(I) complex (8) to N-fused porphyrin Re(I) complex (4) is suggested from the mechanistic study as well as DFT calculations.

  6. Fungal Systematics and Evolution: FUSE 1

    OpenAIRE

    Crous, Pedro W; Schumacher, René K; Wingfield, Michael J; Lombard, Lorenzo; Giraldo, Alejandra; Christensen, Martha; Gardiennet, Alain; Nakashima, Chiharu; Pereira, Olinto L; Smith, Alexander J; Groenewald, Johannes Z

    2015-01-01

    Fungal Systematics and Evolution (FUSE) is introduced as a new series to expedite the publication of issues relating to the epitypification of formerly described species, report new sexual-asexual connections, the merging of sexual and asexual gen¬era following the end of dual nomenclature, and to describe species or note interesting observations regarding fungi. This first paper includes 18 new combinations, 13 new species, three new genera and one new family. All taxa are ascomycetes, excep...

  7. Evaluation of a color fused dual-band NVG

    NARCIS (Netherlands)

    Hogervorst, M.A.; Toet, A.

    2009-01-01

    We designed and evaluated a dual-band Night Vision Goggles sensor system. The sensor system consists of two optically aligned NVGs fitted with filters splitting the sensitive range into a visual and a near-infrared band. The Color-the-night technique (Hogervorst & Toet, FUSION2008) was used to fuse

  8. The burning fuse model of unbecoming in time

    Science.gov (United States)

    Norton, John D.

    2015-11-01

    In the burning fuse model of unbecoming in time, the future is real and the past is unreal. It is used to motivate the idea that there is something unbecoming in the present literature on the metaphysics of time: its focus is merely the assigning of a label "real."

  9. Alkaline phosphatase-fused repebody as a new format of immuno-reagent for an immunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Hyo-Deok; Lee, Joong-jae [Department of Biological Sciences, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 305-701 (Korea, Republic of); Kim, Yu Jung [Industrial Biotechnology and Bioenergy Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), Daejeon (Korea, Republic of); Hantschel, Oliver [School of Life Sciences, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne (Switzerland); Lee, Seung-Goo [Industrial Biotechnology and Bioenergy Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), Daejeon (Korea, Republic of); Kim, Hak-Sung, E-mail: hskim76@kaist.ac.kr [Department of Biological Sciences, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 305-701 (Korea, Republic of)

    2017-01-15

    Enzyme-linked immunoassays based on an antibody-antigen interaction are widely used in biological and medical sciences. However, the conjugation of an enzyme to antibodies needs an additional chemical process, usually resulting in randomly cross-linked molecules and a loss of the binding affinity and enzyme activity. Herein, we present the development of an alkaline phosphatase-fused repebody as a new format of immuno-reagent for immunoassays. A repebody specifically binding to human TNF-α (hTNF-α) was selected through a phage display, and its binding affinity was increased up to 49 nM using a modular engineering approach. A monomeric alkaline phosphatase (mAP), which was previously isolated from a metagenome library, was genetically fused to the repebody as a signal generator, and the resulting repebody-mAP fusion protein was used for direct and sandwich immunoassays of hTNF-α. We demonstrate the utility and potential of the repebody-mAP fusion protein as an immuno-reagent by showing the sensitivity of 216 pg mL{sup −1} for hTNF-α in a sandwich immunoassay. Furthermore, this repebody-mAP fusion protein enabled the detection of hTNF-α spiked in a serum-supplemented medium with high accuracy and reproducibility. It is thus expected that a mAP-fused repebody can be broadly used as an immuno-reagent in immunoassays. - Highlights: • A human TNF-α (hTNF-α)-specific repebody was selected using a phage display. • A monomeric alkaline phosphatase (mAP) was genetically fused to the repebody. • mAP-fused repebody enabled detection of hTNF-α with high sensitivity and accuracy. • mAP-fused repebody can be widely used as a new immuno-reagent in immunoassays.

  10. Peripheral biomarkers revisited: integrative profiling of peripheral samples for psychiatric research.

    Science.gov (United States)

    Hayashi-Takagi, Akiko; Vawter, Marquis P; Iwamoto, Kazuya

    2014-06-15

    Peripheral samples, such as blood and skin, have been used for decades in psychiatric research as surrogates for central nervous system samples. Although the validity of the data obtained from peripheral samples has been questioned and other state-of-the-art techniques, such as human brain imaging, genomics, and induced pluripotent stem cells, seem to reduce the value of peripheral cells, accumulating evidence has suggested that revisiting peripheral samples is worthwhile. Here, we re-evaluate the utility of peripheral samples and argue that establishing an understanding of the common signaling and biological processes in the brain and peripheral samples is required for the validity of such models. First, we present an overview of the available types of peripheral cells and describe their advantages and disadvantages. We then briefly summarize the main achievements of omics studies, including epigenome, transcriptome, proteome, and metabolome analyses, as well as the main findings of functional cellular assays, the results of which imply that alterations in neurotransmission, metabolism, the cell cycle, and the immune system may be partially responsible for the pathophysiology of major psychiatric disorders such as schizophrenia. Finally, we discuss the future utility of peripheral samples for the development of biomarkers and tailor-made therapies, such as multimodal assays that are used as a battery of disease and trait pathways and that might be potent and complimentary tools for use in psychiatric research. © 2013 Society of Biological Psychiatry Published by Society of Biological Psychiatry All rights reserved.

  11. Simulation of microstructure evolution in fused-coating additive manufacturing based on phase field approach

    Directory of Open Access Journals (Sweden)

    Ru-wei Geng

    2017-11-01

    Full Text Available The mechanical properties of metal components are determined by the solidification behaviour and microstructure. A quantitative phase field model is used to investigate the microstructure evolution of fused-coating additive manufacturing, by which to improve the quality of deposition. During the fused-coating process, the molten metal in a crucible flows out of a nozzle and then reaches the substrate. The solidification happens at the moment when the molten metal comes into contact with substrate moving in three-dimensional space. The macroscopic heat transfer model of fused-coating is established to get the temperature field considered as the initial temperature boundary conditions in the phase field model. The numerical and experimental results show that the morphology of grains varies with different solidification environments. Columnar grains are observed during the early period at the bottom of fused-coating layer and the equiaxed grains appear subsequently ahead of the columnar grains. Columnar dendrites phase field simulations about the grains morphology and solute distribution are conducted considering the solidification environments. The simulation results are in good agreement with experimental results.

  12. Synthesis of fused bicyclic piperidines: potential bioactive templates for medicinal chemistry.

    Science.gov (United States)

    Zhou, Jinglan; Campbell-Conroy, Erica L; Silina, Alina; Uy, Johnny; Pierre, Fabrice; Hurley, Dennis J; Hilgraf, Nicole; Frieman, Bryan A; DeNinno, Michael P

    2015-01-02

    An array of six pyridyl-substituted fused bicyclic piperidines was prepared as novel cores for medicinal chemistry. For maximum diversity, the size of the fused ring varied from three to six atoms and contained up to two oxygen atoms. The pyridine ring was incorporated to improve physicochemical properties and to challenge the robustness of the chemistry. The presence of the pyridine did interfere with our initial approaches to these molecules, and in several instances, a blocking strategy had to be employed. These new scaffolds possess high sp3 character and may prove useful in multiple medicinal chemistry applications.

  13. Firefighters United for Safety, Ethics, and Ecology (FUSEE): Torchbearers for a new fire management paradigm

    Science.gov (United States)

    Timothy Ingalsbee; Joseph Fox; Patrick Withen

    2007-01-01

    Firefighters United for Safety, Ethics, and Ecology (FUSEE) is a nonprofit organization promoting safe, ethical, ecological wildland fire management. FUSEE believes firefighter and community safety are ultimately interdependent with ethical public service, wildlands protection, and ecological restoration of fire-adapted ecosystems. Our members include current, former,...

  14. Fused salt electrolysis

    International Nuclear Information System (INIS)

    Ares, Osvaldo; Botbol, Jose.

    1989-01-01

    Working conditions for zirconium preparation by fused salt electrolysis were studied. For such purpose, a cell was built for operation under argon atmosphere. A graphite crucible served as anode, with steel cathodes. Proper design allowed cathode rechange under the inert atmosphere. Cathodic deposits of zirconium powder occluded salts from the bath. After washing with both water and hydrochloric acid, the metallic powder was consolidated by fusion. Optimum operating conditions were found to arise from an electrolyte of 12% potassium hexafluorzirconate -88% sodium chloride, at 820 deg C and 5 A/cm 2 cathodic current density. Deposits contained 35% of metal and current efficiency reached 66%. The powder contained up to 600 ppm of chlorine and 1.700 ppm of fluorine; after fusion, those amounts decreased to 2 ppm and 3 ppm respectively, with low proportion of metallic impurities. Though oxygen proportion was 4.500 ppm, it should be lowered by improving working conditions, as well as working on an ampler scale. (Author)

  15. Peripheral reactions

    International Nuclear Information System (INIS)

    Greiner, D.

    1978-01-01

    Peripheral collisions, that is, collisions involving a small amount of overlap of nuclear matter, are discussed including inclusive interactions, the magnitude of the peripheral cross section, fragmentation, a compilation of experiments and available data, limiting fragmentation, factorization, some models, fragment momentum distributions, and future research directions

  16. Fusing Simulation Results From Multifidelity Aero-servo-elastic Simulators - Application To Extreme Loads On Wind Turbine

    DEFF Research Database (Denmark)

    Abdallah, Imad; Sudret, Bruno; Lataniotis, Christos

    2015-01-01

    Fusing predictions from multiple simulators in the early stages of the conceptual design of a wind turbine results in reduction in model uncertainty and risk mitigation. Aero-servo-elastic is a term that refers to the coupling of wind inflow, aerodynamics, structural dynamics and controls. Fusing...... the response data from multiple aero-servo-elastic simulators could provide better predictive ability than using any single simulator. The co-Kriging approach to fuse information from multifidelity aero-servo-elastic simulators is presented. We illustrate the co-Kriging approach to fuse the extreme flapwise...... bending moment at the blade root of a large wind turbine as a function of wind speed, turbulence and shear exponent in the presence of model uncertainty and non-stationary noise in the output. The extreme responses are obtained by two widely accepted numerical aero-servo-elastic simulators, FAST...

  17. Vacuum fused deposition modelling system to improve tensile ...

    African Journals Online (AJOL)

    In the printing process, the interlayer bonding is made too quick thus the layers are not fully fused together causing the reduced tensile strength. This paper presents a possible solution to this problem by incorporating vacuum technology in FDM system to improve tensile strength of 3D printed specimens. In this study, a ...

  18. The challenges of treating a fused tooth

    OpenAIRE

    Baratto-Filho, Flares; Leonardi, Denise Piotto; Crozeta, Bruno Monguilhott; Baratto, Samantha Pugsley; Campos, Edson Alves; Tomazinho, Flavia Sens Fagundes; Deliberador, Tatiana Miranda

    2012-01-01

    This paper describes and discusses the multidisciplinary treatment involving a permanent maxillary lateral incisor fused to a supernumerary tooth, both presenting pulp necrosis and periapical lesion. A 15-year-old male patient sought treatment complaining of pain, swelling and mobility on the maxillary right lateral incisor. After clinical and radiographic examination, root canal preparation was performed according to the crown-down technique and a calcium hydroxide dressing was placed for 15...

  19. Peripheral Developing Odontoma or Peripheral Ameloblastic Fibroodontoma: A Rare Challenging Case

    Directory of Open Access Journals (Sweden)

    Saede Atarbashi Moghadam

    2016-01-01

    Full Text Available Peripheral odontogenic lesions are considered to be rare within the classification of odontogenic tumors. They share the same microscopic characteristics of their central counterparts. Here, we report an ulcerated mass of the maxillary gingiva that on histopathological examination was diagnosed as peripheral developing odontoma or peripheral ameloblastic fibroodontoma. The diagnosis of this tumor is challenging and may lead to unnecessary treatment.

  20. Peripheral Neuropathy and Agent Orange

    Science.gov (United States)

    ... Enter ZIP code here Enter ZIP code here Peripheral Neuropathy and Agent Orange VA presumes Veterans' early-onset ... 10 percent disabling by VA's rating regulations. About peripheral neuropathy Peripheral neuropathy is a condition of the peripheral ...

  1. Vascular access in neonatology: peripherally inserted central catheter and peripheral venous catheter

    Directory of Open Access Journals (Sweden)

    Marcia Lienemann

    2014-04-01

    The objective of this paper is to present aspects of peripherally inserted central catheter and peripheral venous catheter, highlighting important points in choosing the type of access. For the passage of peripherally inserted central catheter is previously performing specific course necessary, while the primary indication occurs when it is necessary to access the patient's stay for a long period of time. Whereas peripheral venipuncture is the most appropriate in cases of needing an IV line quickly and safely, for the administration of fluids, blood collection, blood transfusion and other.

  2. Fused silica thermal conductivity dispersion at high temperature

    International Nuclear Information System (INIS)

    Bouchut, P.; Decruppe, D.; Delrive, L.

    2004-01-01

    A continuous CO 2 laser is focused to locally anneal small fused silica spots. A noncontact radiometry diagnostic enables us to follow surface temperature variation that occurs from site to site. A 'steady state' dispersion of surface temperature is observed across our sample. We show that nonhomogeneous silica thermal conductivity, above 1000 K is responsible for this temperature dispersion

  3. Evaluation of a color fused dual-band NVG

    NARCIS (Netherlands)

    Hogervorst, M.A.; Toet, A.

    2009-01-01

    We have tested a prototype dual-band NVG system consisting of two NVGs fitted with filters that split the NVG sensitive range into a short (visual) and a long wavelength (NIR) band. The Color-the-night technique (see Hogervorst & Toet, SPIE D&S ‘08) was used to fuse the images of the two sensors. We

  4. Wideband two-port beam splitter of a binary fused-silica phase grating.

    Science.gov (United States)

    Wang, Bo; Zhou, Changhe; Feng, Jijun; Ru, Huayi; Zheng, Jiangjun

    2008-08-01

    The usual beam splitter of multilayer-coated film with a wideband spectrum is not easy to achieve. We describe the realization of a wideband transmission two-port beam splitter based on a binary fused-silica phase grating. To achieve high efficiency and equality in the diffracted 0th and -1st orders, the grating profile parameters are optimized using rigorous coupled-wave analysis at a wavelength of 1550 nm. Holographic recording and the inductively coupled plasma dry etching technique are used to fabricate the fused-silica beam splitter grating. The measured efficiency of (45% x 2) = 90% diffracted into the both orders can be obtained with the fabricated grating under Littrow mounting. The physical mechanism of such a wideband two-port beam splitter grating can be well explained by the modal method based on two-beam interference of the modes excited by the incident wave. With the high damage threshold, low coefficient of thermal expansion, and wideband high efficiency, the presented beam splitter etched in fused silica should be a useful optical element for a variety of practical applications.

  5. IMPROVED UAV-BORNE 3D MAPPING BY FUSING OPTICAL AND LASERSCANNER DATA

    Directory of Open Access Journals (Sweden)

    B. Jutzi

    2013-08-01

    Full Text Available In this paper, a new method for fusing optical and laserscanner data is presented for improved UAV-borne 3D mapping. We propose to equip an unmanned aerial vehicle (UAV with a small platform which includes two sensors: a standard low-cost digital camera and a lightweight Hokuyo UTM-30LX-EW laserscanning device (210 g without cable. Initially, a calibration is carried out for the utilized devices. This involves a geometric camera calibration and the estimation of the position and orientation offset between the two sensors by lever-arm and bore-sight calibration. Subsequently, a feature tracking is performed through the image sequence by considering extracted interest points as well as the projected 3D laser points. These 2D results are fused with the measured laser distances and fed into a bundle adjustment in order to obtain a Simultaneous Localization and Mapping (SLAM. It is demonstrated that an improvement in terms of precision for the pose estimation is derived by fusing optical and laserscanner data.

  6. Evaluation of optical properties of the amorphous carbon film on fused silica

    International Nuclear Information System (INIS)

    Baydogan, Nilguen Dogan

    2004-01-01

    Deposition was done using a pulsed filtered cathodic arc with a graphite cathode. The carbon plasma is fully ionised and condenses on the substrate, forming diamond-like material but with amorphous structure. Optical properties of amorphous carbon films on fused-silica glass were investigated and the curves of optical density have a characteristic band at approximately 950 nm. Changes of the colourimetric quantities were evaluated and compared to uncoated fused silica glass. These changes were investigated as a function of the applied substrate bias voltage using the CIE and CIELAB colour systems. It is suggested that the mechanism of absorption is related to an allowed direct transition at the amorphous carbon films on fused silica glass. The optical energy gap of the amorphous carbon film depends on the bias voltage applied to the substrate holder. The optical colour parameters and optical band gap indicated that there is a relation between the dominant wavelength of the reflectance in the visible range and the wavelength of the optical band gap

  7. Fused Reality for Enhanced Flight Test Capabilities

    Science.gov (United States)

    Bachelder, Ed; Klyde, David

    2011-01-01

    The feasibility of using Fused Reality-based simulation technology to enhance flight test capabilities has been investigated. In terms of relevancy to piloted evaluation, there remains no substitute for actual flight tests, even when considering the fidelity and effectiveness of modern ground-based simulators. In addition to real-world cueing (vestibular, visual, aural, environmental, etc.), flight tests provide subtle but key intangibles that cannot be duplicated in a ground-based simulator. There is, however, a cost to be paid for the benefits of flight in terms of budget, mission complexity, and safety, including the need for ground and control-room personnel, additional aircraft, etc. A Fused Reality(tm) (FR) Flight system was developed that allows a virtual environment to be integrated with the test aircraft so that tasks such as aerial refueling, formation flying, or approach and landing can be accomplished without additional aircraft resources or the risk of operating in close proximity to the ground or other aircraft. Furthermore, the dynamic motions of the simulated objects can be directly correlated with the responses of the test aircraft. The FR Flight system will allow real-time observation of, and manual interaction with, the cockpit environment that serves as a frame for the virtual out-the-window scene.

  8. Non-destructive testing of rocket fuse by thermal neutron radiography

    International Nuclear Information System (INIS)

    An Fulin; Li Furong

    1999-01-01

    A neutron radiography system in reactor horizontal hole of Tsinghua University was introduced, and its capability of neutron radiography was evaluated by theory and experiment, the non-destructive testing for rocket fuse is successful

  9. Searching for Models Exhibiting High Circularly Polarized Luminescence: the Electroactive Inherently Chiral Oligothiophenes.

    Science.gov (United States)

    Benincori, Tiziana; Appoloni, Giulio; Mussini, Patrizia Romana; Arnaboldi, Serena; Cirilli, Roberto; Quartapelle Procopio, Elsa; Panigati, Monica; Abbate, Sergio; Mazzeo, Giuseppe; Longhi, Giovanna

    2018-05-02

    Two new inherently chiral oligothiophenes characterized by the atropisomeric 3,3'-bithianaphtene scaffold functionalized with fused ring bithiophene derivatives, namely 4H-cyclopenta [2,1-b3:4b']dithiophene (CPDT) and dithieno[3,3-b:2',3'-d]pyrrole (DTP), were synthesized. The racemates were fully characterized and resolved into antipodes by enantioselective HPLC. The enantiomers were analyzed through different chiroptical techniques: electronic circular dichroism (ECD) and vibrational circular dichroism (VCD) were employed to attribute the absolute configuration (AC). Comparison of experimental and calculated VCD spectra confirmed the DFT calculated conformational characteristics. The compound functionalized with two CPDT units was oxidized with FeCl3 and ECD and CPL of the resulting material were measured. Circularly Polarized Luminescence (CPL) was measured in order to verify if inherently chiral oligothiophenes could be promising systems for chiral photonics applications. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Automatic polymerase chain reaction product detection system for food safety monitoring using zinc finger protein fused to luciferase

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Wataru; Kezuka, Aki; Murakami, Yoshiyuki; Lee, Jinhee; Abe, Koichi [Department of Biotechnology and Life Science, Tokyo University of Agriculture and Technology, 2-24-16 Naka-cho, Koganei, Tokyo 184-8588 (Japan); Motoki, Hiroaki; Matsuo, Takafumi; Shimura, Nobuaki [System Instruments Co., Ltd., 776-2 Komiya-cho, Hachioji, Tokyo 192-0031 (Japan); Noda, Mamoru; Igimi, Shizunobu [Division of Biomedical Food Research, National Institute of Health Sciences, 1-18-1 Kamiyoga, Setagaya-ku, Tokyo 158-8501 (Japan); Ikebukuro, Kazunori, E-mail: ikebu@cc.tuat.ac.jp [Department of Biotechnology and Life Science, Tokyo University of Agriculture and Technology, 2-24-16 Naka-cho, Koganei, Tokyo 184-8588 (Japan)

    2013-11-01

    Graphical abstract: -- Highlights: •Zif268 fused to luciferase was used for E. coli O157, Salmonella and coliform detection. •Artificial zinc finger protein fused to luciferase was constructed for Norovirus detection. •An analyzer that automatically detects PCR products by zinc finger protein fused to luciferase was developed. •Target pathogens were specifically detected by the automatic analyzer with zinc finger protein fused to luciferase. -- Abstract: An automatic polymerase chain reaction (PCR) product detection system for food safety monitoring using zinc finger (ZF) protein fused to luciferase was developed. ZF protein fused to luciferase specifically binds to target double stranded DNA sequence and has luciferase enzymatic activity. Therefore, PCR products that comprise ZF protein recognition sequence can be detected by measuring the luciferase activity of the fusion protein. We previously reported that PCR products from Legionella pneumophila and Escherichia coli (E. coli) O157 genomic DNA were detected by Zif268, a natural ZF protein, fused to luciferase. In this study, Zif268–luciferase was applied to detect the presence of Salmonella and coliforms. Moreover, an artificial zinc finger protein (B2) fused to luciferase was constructed for a Norovirus detection system. In the luciferase activity detection assay, several bound/free separation process is required. Therefore, an analyzer that automatically performed the bound/free separation process was developed to detect PCR products using the ZF–luciferase fusion protein. By means of the automatic analyzer with ZF–luciferase fusion protein, target pathogenic genomes were specifically detected in the presence of other pathogenic genomes. Moreover, we succeeded in the detection of 10 copies of E. coli BL21 without extraction of genomic DNA by the automatic analyzer and E. coli was detected with a logarithmic dependency in the range of 1.0 × 10 to 1.0 × 10{sup 6} copies.

  11. Automatic polymerase chain reaction product detection system for food safety monitoring using zinc finger protein fused to luciferase

    International Nuclear Information System (INIS)

    Yoshida, Wataru; Kezuka, Aki; Murakami, Yoshiyuki; Lee, Jinhee; Abe, Koichi; Motoki, Hiroaki; Matsuo, Takafumi; Shimura, Nobuaki; Noda, Mamoru; Igimi, Shizunobu; Ikebukuro, Kazunori

    2013-01-01

    Graphical abstract: -- Highlights: •Zif268 fused to luciferase was used for E. coli O157, Salmonella and coliform detection. •Artificial zinc finger protein fused to luciferase was constructed for Norovirus detection. •An analyzer that automatically detects PCR products by zinc finger protein fused to luciferase was developed. •Target pathogens were specifically detected by the automatic analyzer with zinc finger protein fused to luciferase. -- Abstract: An automatic polymerase chain reaction (PCR) product detection system for food safety monitoring using zinc finger (ZF) protein fused to luciferase was developed. ZF protein fused to luciferase specifically binds to target double stranded DNA sequence and has luciferase enzymatic activity. Therefore, PCR products that comprise ZF protein recognition sequence can be detected by measuring the luciferase activity of the fusion protein. We previously reported that PCR products from Legionella pneumophila and Escherichia coli (E. coli) O157 genomic DNA were detected by Zif268, a natural ZF protein, fused to luciferase. In this study, Zif268–luciferase was applied to detect the presence of Salmonella and coliforms. Moreover, an artificial zinc finger protein (B2) fused to luciferase was constructed for a Norovirus detection system. In the luciferase activity detection assay, several bound/free separation process is required. Therefore, an analyzer that automatically performed the bound/free separation process was developed to detect PCR products using the ZF–luciferase fusion protein. By means of the automatic analyzer with ZF–luciferase fusion protein, target pathogenic genomes were specifically detected in the presence of other pathogenic genomes. Moreover, we succeeded in the detection of 10 copies of E. coli BL21 without extraction of genomic DNA by the automatic analyzer and E. coli was detected with a logarithmic dependency in the range of 1.0 × 10 to 1.0 × 10 6 copies

  12. Dual-function beam splitter of a subwavelength fused-silica grating.

    Science.gov (United States)

    Feng, Jijun; Zhou, Changhe; Zheng, Jiangjun; Cao, Hongchao; Lv, Peng

    2009-05-10

    We present the design and fabrication of a novel dual-function subwavelength fused-silica grating that can be used as a polarization-selective beam splitter. For TM polarization, the grating can be used as a two-port beam splitter at a wavelength of 1550 nm with a total diffraction efficiency of 98%. For TE polarization, the grating can function as a high-efficiency grating, and the diffraction efficiency of the -1st order is 95% under Littrow mounting. This dual-function grating design is based on a simplified modal method. By using the rigorous coupled-wave analysis, the optimum grating parameters can be determined. Holographic recording technology and inductively coupled plasma etching are used to manufacture the fused-silica grating. Experimental results are in agreement with the theoretical values.

  13. Cerium-doped scintillating fused-silica fibers

    Science.gov (United States)

    Akchurin, N.; Cowden, C.; Damgov, J.; Dragoiu, C.; Dudero, P.; Faulkner, J.; Kunori, S.

    2018-04-01

    We report on a set of measurements made on (scintillating) cerium-doped fused-silica fibers using high-energy particle beams. These fibers were uniformly embedded in a copper absorber in order to utilize electromagnetic showers as a source of charged particles for generating signals. This new type of cerium-doped fiber potentially offers myriad new applications in calorimeters in high-energy physics, tracking systems, and beam monitoring detectors for future applications. The light yield, pulse shape, attenuation length, and light propagation speeds are given and discussed. Possible future applications are also explored.

  14. Sequential Multicomponent Strategy for the Diastereoselective Synthesis of Densely Functionalized Spirooxindole-Fused Thiazolidines.

    Science.gov (United States)

    Rainoldi, Giulia; Begnini, Fabio; de Munnik, Mariska; Lo Presti, Leonardo; Vande Velde, Christophe M L; Orru, Romano; Lesma, Giordano; Ruijter, Eelco; Silvani, Alessandra

    2018-02-12

    We developed two Ugi-type three-component reactions of spirooxindole-fused 3-thiazolines, isocyanides, and either carboxylic acids or trimethylsilyl azide, to give highly functionalized spirooxindole-fused thiazolidines. Two diverse libraries were generated using practical and robust procedures affording the products in typically good yields. The obtained thiazolidines proved to be suitable substrates for further transformations. Notably, both the Ugi-Joullié and the azido-Ugi reactions resulted highly diastereoselective, affording predominantly the trans-configured products, as confirmed by X-ray crystallographic analysis.

  15. Nanodrilling of fused silica using nanosecond laser radiation

    Energy Technology Data Exchange (ETDEWEB)

    Lorenz, P., E-mail: pierre.lorenz@iom-leipzig.de; Zajadacz, J.; Bayer, L.; Ehrhardt, M.; Zimmer, K.

    2015-10-01

    Graphical abstract: - Highlights: • Low-fluence irradiation of 10 nm Mo on SiO{sub 2} results in the formation of Mo droplets. • High-fluence irradiation of droplets results in the formation of holes in the SiO{sub 2}. • The process allows the formation of randomly distributed and periodic holes. • The randomly distributed hole density ρ{sub h} depends on the fluence (ρ{sub h} ≤ 1.3 μm{sup −2}). • The interaction of the laser beam with Mo/SiO{sub 2} was simulated by FEM. - Abstract: The fast laser drilling of dielectric surfaces with hole diameters in the sub-μm range and a high aspect ratio is a challenge for laser methods. In this study, a novel laser structuring method for the production of randomly and periodically distributed holes in a fused silica surface will be presented using a self-assembling process. A fused silica surface was covered with a 10 nm thick magnetron-sputtered molybdenum film. The metal film was irradiated by a KrF excimer laser (wavelength λ = 248 nm, pulse duration Δt{sub p} = 25 ns) with low laser fluences (Φ < 1 J/cm{sup 2}) and the laser-induced heating resulting in a melting of the metal film and finally in a self-assembled formation of randomly distributed metal droplets due to the surface tension of the metal liquid phase using a top hat beam profile. Furthermore, the usage of a periodically modulated laser beam profile allows the fabrication of periodically distributed droplet pattern. The multi-pulse irradiation of the laser-generated metal droplets with higher laser fluences results in a stepwise evaporation of the metal and in a partial evaporation of the fused silica near the metal droplets. Finally, the laser-induced stepwise evaporation process results in a formation of cone-like holes in the fused silica surface where the resultant holes are dependent on the size of the generated metal droplets and on the laser parameters. The “drilling” process allows the fabrication of holes with a depth up to 1

  16. Imaging subsurface damage of grinded fused silica optics by confocal fluorescence microscopy

    International Nuclear Information System (INIS)

    Neauport, J.; Cormont, P.; Destribats, J.; Legros, P.; Ambard, C.

    2009-01-01

    We report an experimental investigation of fluorescence confocal microscopy as a tool to measure subsurface damage on grinded fused silica optics. Confocal fluorescence microscopy was performed with an excitation at the wavelength of 405 nm on fixed abrasive diamond grinded fused silica samples. We detail the measured fluorescence spectrums and compare them to those of oil based coolants and grinding slurries. We evidence that oil based coolant used in diamond grinding induces a fluorescence that marks the subsurface damages and eases its observation. Such residual traces might also be involved in the laser damage process. (authors)

  17. Optimum inductively coupled plasma etching of fused silica to remove subsurface damage layer

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Xiaolong; Liu, Ying, E-mail: liuychch@ustc.edu.cn; Liu, Zhengkun; Qiu, Keqiang; Xu, Xiangdong; Hong, Yilin; Fu, Shaojun

    2015-11-15

    Highlights: • SSD layer of fused silica is removed by ICP etch with surface roughness of 0.23 nm. • Metal contamination is successfully avoided by employing an isolation device. • Unique low-density plasma induced pitting damage is discovered and eliminated. • Lateral etching of SSD is avoided due to the improvement of etching anisotropy. - Abstract: In this work, we introduce an optimum ICP etching technique that successfully removes the subsurface damage (SSD) layer of fused silica without causing plasma induced surface damage (PISD) or lateral etching of SSD. As one of the commonest PISD initiators, metal contamination from reactor chamber is prevented by employing a simple isolation device. Based on this device, a unique low-density pitting damage is discovered and subsequently eliminated by optimizing the etching parameters. Meanwhile etching anisotropy also improves a lot, thus preventing the lateral etching of SSD. Using this proposed technique, SSD layer of fused silica is successfully removed with a surface roughness of 0.23 nm.

  18. Development of electro fused aggregates for use in refractories for the burning zone of cement kilns

    International Nuclear Information System (INIS)

    Ferreira, Luis Leonardo Horne Curimbaba

    2006-01-01

    Electro fused aggregates are largely used in refractory production due to the better performance reached when they are employed. In this work electro fused aggregates were designed for application in refractories for the burning zone of cement kilns. Initially reaction evaluation was conducted aiming the identification of the most prone refractory systems when single refractory phases react with Portland cement phases at high temperatures. In the next step, raw materials of the best refractory systems were electro fused to generate different aggregate compositions. The electro fused aggregates properties were evaluated and the classified ones were used to produce refractory bricks for the burning zone of cement kilns. General characteristics of these bricks were measured and compared with a standard magnesia-spinel refractory. Aggregates of the system Mg O - TiO 2 - Ca O, more specifically aggregates belonged to the compatibility triangle Mg O - Mg 2 TiO 4 - CaTiO 3 , showed suitable characteristics for development of refractories for the burning zone cement kilns. (author)

  19. Highly sensitive determination of hydroxylamine using fused gold nanoparticles immobilized on sol-gel film modified gold electrode

    Energy Technology Data Exchange (ETDEWEB)

    Kannan, P. [Department of Chemistry, Gandhigram Rural University, Gandhigram 624302, Dindigul, Tamilnadu (India); John, S. Abraham, E-mail: abrajohn@yahoo.co.in [Department of Chemistry, Gandhigram Rural University, Gandhigram 624302, Dindigul, Tamilnadu (India)

    2010-03-24

    We are reporting the highly sensitive determination of hydroxylamine (HA) using 2-mercapto-4-methyl-5-thiazoleacetic acid (TAA) capped fused spherical gold nanoparticles (AuNPs) modified Au electrode. The fused TAA-AuNPs were immobilized on (3-mercaptopropyl)-trimethoxysilane (MPTS) sol-gel film, which was pre-assembled on Au electrode. The immobilization of fused TAA-AuNPs on MPTS sol-gel film was confirmed by UV-vis absorption spectroscopy and atomic force microscopy (AFM). The AFM image showed that the AuNPs retained the fused spherical morphology after immobilized on sol-gel film. The fused TAA-AuNPs on MPTS modified Au electrode were used for the determination of HA in phosphate buffer (PB) solution (pH = 7.2). When compared to bare Au electrode, the fused AuNPs modified electrode not only shifted the oxidation potential of HA towards less positive potential but also enhanced its oxidation peak current. Further, the oxidation of HA was highly stable at fused AuNPs modified electrode. Using amperometric method, determination of 17.5 nM HA was achieved for the first time. Further, the current response of HA increases linearly while increasing its concentration from 17.5 nM to 22 mM and a detection limit was found to be 0.39 nM (S/N = 3). The present modified electrode was also successfully used for the determination of 17.5 nM HA in the presence of 200-fold excess of common interferents such as urea, NO{sub 2}{sup -}, NH{sub 4}{sup +}, oxalate, Mn{sup 2+}, Na{sup +}, K{sup +}, Mg{sup 2+}, Ca{sup 2+}, Ba{sup 2+} and Cu{sup 2+}. The practical application of the present modified electrode was demonstrated by measuring the concentration of HA in ground water samples.

  20. Trichohyalin-like 1 protein, a member of fused S100 proteins, is expressed in normal and pathologic human skin

    Energy Technology Data Exchange (ETDEWEB)

    Yamakoshi, Takako [Department of Dermatology, Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, Sugitani, Toyama 930-0194 (Japan); Makino, Teruhiko, E-mail: tmakino@med.u-toyama.ac.jp [Department of Dermatology, Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, Sugitani, Toyama 930-0194 (Japan); Ur Rehman, Mati; Yoshihisa, Yoko [Department of Dermatology, Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, Sugitani, Toyama 930-0194 (Japan); Sugimori, Michiya [Department of Integrative Neuroscience, Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, Sugitani, Toyama 930-0194 (Japan); Shimizu, Tadamichi, E-mail: shimizut@med.u-toyama.ac.jp [Department of Dermatology, Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, Sugitani, Toyama 930-0194 (Japan)

    2013-03-01

    Highlights: ► Trichohyalin-like 1 protein is a member of the fused-type S100 protein gene family. ► Specific antibodies against the C-terminus of the TCHHL1 protein were generated. ► TCHHL1 proteins were expressed in the basal layer of the normal epidermis. ► TCHHL1 proteins were strongly expressed in tumor nests of BCC and SCC. ► The expression of TCHHL1 proteins increased in epidermis of psoriasis vulgaris. - Abstract: Trichohyalin-like 1 (TCHHL1) protein is a novel member of the fused-type S100 protein gene family. The deduced amino acid sequence of TCHHL1 contains an EF-hand domain in the N-terminus, one trans-membrane domain and a nuclear localization signal. We generated specific antibodies against the C-terminus of the TCHHL1 protein and examined the expression of TCHHL1 proteins in normal and pathological human skin. An immunohistochemical study showed that TCHHL1 proteins were expressed in the basal layer of the normal epidermis. In addition, signals of TCHHL1 proteins were observed around the nuclei of cultured growing keratinocytes. Accordingly, TCHHL1 mRNA has been detected in normal skin and cultured growing keratinocytes. Furthermore, TCHHL1 proteins were strongly expressed in the peripheral areas of tumor nests in basal cell carcinomas and squamous cell carcinomas. A dramatic increase in the number of Ki67 positive cells was observed in TCHHL1-expressing areas. The expression of TCHHL1 proteins also increased in non-cancerous hyperproliferative epidermal tissues such as those of psoriasis vulgaris and lichen planus. These findings highlight the possibility that TCHHL1 proteins are expressed in growing keratinocytes of the epidermis and might be associated with the proliferation of keratinocytes.

  1. Trichohyalin-like 1 protein, a member of fused S100 proteins, is expressed in normal and pathologic human skin

    International Nuclear Information System (INIS)

    Yamakoshi, Takako; Makino, Teruhiko; Ur Rehman, Mati; Yoshihisa, Yoko; Sugimori, Michiya; Shimizu, Tadamichi

    2013-01-01

    Highlights: ► Trichohyalin-like 1 protein is a member of the fused-type S100 protein gene family. ► Specific antibodies against the C-terminus of the TCHHL1 protein were generated. ► TCHHL1 proteins were expressed in the basal layer of the normal epidermis. ► TCHHL1 proteins were strongly expressed in tumor nests of BCC and SCC. ► The expression of TCHHL1 proteins increased in epidermis of psoriasis vulgaris. - Abstract: Trichohyalin-like 1 (TCHHL1) protein is a novel member of the fused-type S100 protein gene family. The deduced amino acid sequence of TCHHL1 contains an EF-hand domain in the N-terminus, one trans-membrane domain and a nuclear localization signal. We generated specific antibodies against the C-terminus of the TCHHL1 protein and examined the expression of TCHHL1 proteins in normal and pathological human skin. An immunohistochemical study showed that TCHHL1 proteins were expressed in the basal layer of the normal epidermis. In addition, signals of TCHHL1 proteins were observed around the nuclei of cultured growing keratinocytes. Accordingly, TCHHL1 mRNA has been detected in normal skin and cultured growing keratinocytes. Furthermore, TCHHL1 proteins were strongly expressed in the peripheral areas of tumor nests in basal cell carcinomas and squamous cell carcinomas. A dramatic increase in the number of Ki67 positive cells was observed in TCHHL1-expressing areas. The expression of TCHHL1 proteins also increased in non-cancerous hyperproliferative epidermal tissues such as those of psoriasis vulgaris and lichen planus. These findings highlight the possibility that TCHHL1 proteins are expressed in growing keratinocytes of the epidermis and might be associated with the proliferation of keratinocytes

  2. Drug-induced peripheral neuropathy

    DEFF Research Database (Denmark)

    Vilholm, Ole Jakob; Christensen, Alex Alban; Zedan, Ahmed

    2014-01-01

    Peripheral neuropathy can be caused by medication, and various descriptions have been applied for this condition. In this MiniReview, the term 'drug-induced peripheral neuropathy' (DIPN) is used with the suggested definition: Damage to nerves of the peripheral nervous system caused by a chemical...... substance used in the treatment, cure, prevention or diagnosis of a disease. Optic neuropathy is included in this definition. A distinction between DIPN and other aetiologies of peripheral neuropathy is often quite difficult and thus, the aim of this MiniReview is to discuss the major agents associated...

  3. The FUSE satellite is encased in a canister before being moved to the Launch Pad.

    Science.gov (United States)

    1999-01-01

    At Hangar AE, Cape Canaveral Air Station (CCAS), the last segment is lifted over the top of NASA's Far Ultraviolet Spectroscopic Explorer (FUSE) satellite already encased in a protective canister. The satellite will next be moved to Launch Pad 17A, CCAS, for its scheduled launch June 23 aboard a Boeing Delta II rocket. FUSE was developed by The Johns Hopkins University under contract to Goddard Space Flight Center, Greenbelt, Md., to investigate the origin and evolution of the lightest elements in the universe - hydrogen and deuterium. In addition, the FUSE satellite will examine the forces and process involved in the evolution of the galaxies, stars and planetary systems by investigating light in the far ultraviolet portion of the electromagnetic spectrum.

  4. Titanium metal obtention by fused salts electrolysis

    International Nuclear Information System (INIS)

    Perillo, P.M.; Ares, Osvaldo; Botbol, Jose.

    1989-01-01

    Potassium fluorotitanate dissolved in fused sodium chloride or potassium chloride may be electrolyzed under an inert gas atmosphere. Solid electrolysis products are formed on the cathode which contains titanium metal, sodium chloride, lower fluorotitanates and small quantities of alkali metal fluorotitanate. The extraction of titanium from the electrolysis products may be carried out by aqueous leaching (removal of chloride salts of alkali metals and a certain amount of fluorotitanates). Titanium metal obtained is relatively pure. (Author)

  5. Fused Adaptive Lasso for Spatial and Temporal Quantile Function Estimation

    KAUST Repository

    Sun, Ying; Wang, Huixia J.; Fuentes, Montserrat

    2015-01-01

    and temporal data with a fused adaptive Lasso penalty to accommodate the dependence in space and time. This method penalizes the difference among neighboring quantiles, hence it is desirable for applications with features ordered in time or space without

  6. Electric fuses operation, a review: 2. Arcing period

    International Nuclear Information System (INIS)

    Bussière, W

    2012-01-01

    In the electric fuse operation the arcing period follows immediately the pre-arcing period depicted in Part 1 (Part 1. Pre-arcing period). The transition between these two operation steps is not fully understood at this time. To simplify the beginning of the arcing period can be identified with the electric arc ignition i.e. with the electrodes voltage drop. The consecutive plasma is of metallic type at the beginning of the arcing period and of metallic plus silica type with varying mixture up to the end of the arcing period. The energy brought by the fault current is withdrawn by means of the interaction between the electric arc and the arc quenching material (usually silica sand) whose morphometric properties influence the properties of the plasma column: composition, thermodynamic properties and transport coefficients of the plasma column depend on the porosity (and other morphometric properties) of the filler. The fuse element erosion also known as burn-back is responsible for the lengthening of the plasma column and the variations of the electric field. The whole of these processes is depicted by means of experimental results or modellings when possible.

  7. Planning the FUSE Mission Using the SOVA Algorithm

    Science.gov (United States)

    Lanzi, James; Heatwole, Scott; Ward, Philip R.; Civeit, Thomas; Calvani, Humberto; Kruk, Jeffrey W.; Suchkov, Anatoly

    2011-01-01

    Three documents discuss the Sustainable Objective Valuation and Attainability (SOVA) algorithm and software as used to plan tasks (principally, scientific observations and associated maneuvers) for the Far Ultraviolet Spectroscopic Explorer (FUSE) satellite. SOVA is a means of managing risk in a complex system, based on a concept of computing the expected return value of a candidate ordered set of tasks as a product of pre-assigned task values and assessments of attainability made against qualitatively defined strategic objectives. For the FUSE mission, SOVA autonomously assembles a week-long schedule of target observations and associated maneuvers so as to maximize the expected scientific return value while keeping the satellite stable, managing the angular momentum of spacecraft attitude- control reaction wheels, and striving for other strategic objectives. A six-degree-of-freedom model of the spacecraft is used in simulating the tasks, and the attainability of a task is calculated at each step by use of strategic objectives as defined by use of fuzzy inference systems. SOVA utilizes a variant of a graph-search algorithm known as the A* search algorithm to assemble the tasks into a week-long target schedule, using the expected scientific return value to guide the search.

  8. Fusing Eye-gaze and Speech Recognition for Tracking in an Automatic Reading Tutor

    DEFF Research Database (Denmark)

    Rasmussen, Morten Højfeldt; Tan, Zheng-Hua

    2013-01-01

    In this paper we present a novel approach for automatically tracking the reading progress using a combination of eye-gaze tracking and speech recognition. The two are fused by first generating word probabilities based on eye-gaze information and then using these probabilities to augment the langu......In this paper we present a novel approach for automatically tracking the reading progress using a combination of eye-gaze tracking and speech recognition. The two are fused by first generating word probabilities based on eye-gaze information and then using these probabilities to augment...

  9. Laser-assisted selective fusing of thermal sprayed Ni-based self-fluxing alloys by using high-power diode lasers

    Science.gov (United States)

    Chun, Eun-Joon; Kim, Min-Su; Nishikawa, Hiroshi; Park, Changkyoo; Suh, Jeong

    2018-03-01

    Fusing treatment of Ni-based self-fluxing alloys (Metco-16C and 1276F) was performed using high-power diode lasers to control the temperature of the substrate's surface in real time. The effects of the fusing treatment temperature on the microstructural change and hardness distribution were also investigated. For Metco-16C and 1276F, the macrostructural inhomogeneity (voids) within the thermal sprayed layer decreased considerably as the fusing temperature increased. For both self-fluxing alloys, the optimal temperature for fusing was approximately 1423 K (for Metco-16C) and 1373 K (for 1276F), both of which are within the solid state temperature range; these temperatures maximize the alloy hardness together with the macrostructural homogeneity. In this temperature range, the microstructure consists of a lamellar-structured matrix phase with fine (diode laser system.

  10. The size prediction of potential inclusions embedded in the sub-surface of fused silica by damage morphology

    Directory of Open Access Journals (Sweden)

    Gao Xiang

    2017-04-01

    Full Text Available A model for predicting the size ranges of different potential inclusions initiating damage on the surface of fused silica has been presented. This accounts for the heating of nanometric inclusions whose absorptivity is described based on Mie Theory. The depth profile of impurities has been measured by ICP-OES. By the measured temporal pulse profile on the surface of fused silica, the temperature and thermal stress has been calculated. Furthermore, considering the limit conditions of temperature and thermal stress strength for different damage morphologies, the size range of potential inclusions for fused silica is discussed.

  11. Ultraviolet Laser Damage Dependence on Contamination Concentration in Fused Silica Optics during Reactive Ion Etching Process

    Directory of Open Access Journals (Sweden)

    Laixi Sun

    2018-04-01

    Full Text Available The reactive ion etching (RIE process of fused silica is often accompanied by surface contamination, which seriously degrades the ultraviolet laser damage performance of the optics. In this study, we find that the contamination behavior on the fused silica surface is very sensitive to the RIE process which can be significantly optimized by changing the plasma generating conditions such as discharge mode, etchant gas and electrode material. Additionally, an optimized RIE process is proposed to thoroughly remove polishing-introduced contamination and efficiently prevent the introduction of other contamination during the etching process. The research demonstrates the feasibility of improving the damage performance of fused silica optics by using the RIE technique.

  12. Chlorotoxin Fused to IgG-Fc Inhibits Glioblastoma Cell Motility via Receptor-Mediated Endocytosis

    Directory of Open Access Journals (Sweden)

    Tomonari Kasai

    2012-01-01

    Full Text Available Chlorotoxin is a 36-amino acid peptide derived from Leiurus quinquestriatus (scorpion venom, which has been shown to inhibit low-conductance chloride channels in colonic epithelial cells. Chlorotoxin also binds to matrix metalloproteinase-2 and other proteins on glioma cell surfaces. Glioma cells are considered to require the activation of matrix metalloproteinase-2 during invasion and migration. In this study, for targeting glioma, we designed two types of recombinant chlorotoxin fused to human IgG-Fcs with/without a hinge region. Chlorotoxin fused to IgG-Fcs was designed as a dimer of 60 kDa with a hinge region and a monomer of 30 kDa without a hinge region. The monomeric and dimeric forms of chlorotoxin inhibited cell proliferation at 300 nM and induced internalization in human glioma A172 cells. The monomer had a greater inhibitory effect than the dimer; therefore, monomeric chlorotoxin fused to IgG-Fc was multivalently displayed on the surface of bionanocapsules to develop a drug delivery system that targeted matrix metalloproteinase-2. The target-dependent internalization of bionanocapsules in A172 cells was observed when chlorotoxin was displayed on the bionanocapsules. This study indicates that chlorotoxin fused to IgG-Fcs could be useful for the active targeting of glioblastoma cells.

  13. A Real-Time Embedded Control System for Electro-Fused Magnesia Furnace

    Directory of Open Access Journals (Sweden)

    Fang Zheng

    2013-01-01

    Full Text Available Since smelting process of electro-fused magnesia furnace is a complicated process which has characteristics like complex operation conditions, strong nonlinearities, and strong couplings, traditional linear controller cannot control it very well. Advanced intelligent control strategy is a good solution to this kind of industrial process. However, advanced intelligent control strategy always involves huge programming task and hard debugging and maintaining problems. In this paper, a real-time embedded control system is proposed for the process control of electro-fused magnesia furnace based on intelligent control strategy and model-based design technology. As for hardware, an embedded controller based on an industrial Single Board Computer (SBC is developed to meet industrial field environment demands. As for software, a Linux based on Real-Time Application Interface (RTAI is used as the real-time kernel of the controller to improve its real-time performance. The embedded software platform is also modified to support generating embedded code automatically from Simulink/Stateflow models. Based on the proposed embedded control system, the intelligent embedded control software of electro-fused magnesium furnace can be directly generated from Simulink/Stateflow models. To validate the effectiveness of the proposed embedded control system, hardware-in-the-loop (HIL and industrial field experiments are both implemented. Experiments results show that the embedded control system works very well in both laboratory and industry environments.

  14. Mononuclear Clusterfullerene Single-Molecule Magnet Containing Strained Fused-Pentagons Stabilized by a Nearly Linear Metal Cyanide Cluster

    DEFF Research Database (Denmark)

    Liu, Fupin; Wang, Song; Gao, Cong Li

    2017-01-01

    Fused-pentagons results in an increase of local steric strain according to the isolated pentagon rule (IPR), and for all reported non-IPR clusterfullerenes multiple (two or three) metals are required to stabilize the strained fused-pentagons, making it difficult to access the single-atom properti...... (SMM)....

  15. Influence of piezoceramic to fused silica plate thickness on the radii of curvature of piezoelectric bimorph mirror

    International Nuclear Information System (INIS)

    Libu, M.; Susanth, S.; Vasanthakumari, K. G.; Dileep Kumar, C. J.; Raghu, N.

    2012-01-01

    Piezoelectric based bimorph mirrors (PBM) find extensive use in focusing of x-ray beams. Many optical instruments require use of PBM whose radii of curvature can be tuned precisely. The 100 mm and 300 mm PBMs were fabricated with varying piezoelectric to fused silica plate thicknesses. The radii of curvature of free standing mirrors were measured as a function of voltage and it was found to decrease with increasing voltage. For a given piezoelectric plate thickness, as the fused silica thickness increases, the radii of curvature was found to increase owing to increase in stiffness of the mirror. On the other hand, for a given fused silica plate thickness, when the piezoelectric plate thickness is increased, the radii of curvature are decreased for a given electric field, due to increase in generated force. This study brings out the influence of piezoceramic to fused silica plate thickness on the radii of curvature of PBM.

  16. Primary retroperitoneal teratoma and crossed fused renal ectopia with turner's syndrome -a case report-

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yun Jung; Hong, Ki Ung [St. Francisco General Hospital, New York (United States)

    1988-02-15

    In 1938, Turner described a clinical entity in phenotype females characterized by sexual infantilism, congenital webbed neck and cubitus valgus. After then, the occurrence of renal anomalies in patients with Turner's syndrome has been recognized. Associated crossed fused renal ectopia is very rare. Primary retroperitoneal teratoma is also rare and usually during childhood. The authors report a case of primary retroperitoneal teratoma and crossed fused renal ectopia with Turner's syndrome (mosaic type). The clinical, pathological and radiographical findings are reviewed.

  17. Primary retroperitoneal teratoma and crossed fused renal ectopia with turner's syndrome -a case report-

    International Nuclear Information System (INIS)

    Kim, Yun Jung; Hong, Ki Ung

    1988-01-01

    In 1938, Turner described a clinical entity in phenotype females characterized by sexual infantilism, congenital webbed neck and cubitus valgus. After then, the occurrence of renal anomalies in patients with Turner's syndrome has been recognized. Associated crossed fused renal ectopia is very rare. Primary retroperitoneal teratoma is also rare and usually during childhood. The authors report a case of primary retroperitoneal teratoma and crossed fused renal ectopia with Turner's syndrome (mosaic type). The clinical, pathological and radiographical findings are reviewed

  18. Propylthiouracil and peripheral neuropathy

    Directory of Open Access Journals (Sweden)

    Valentina Van Boekel

    1992-06-01

    Full Text Available Peripheral neuropathy is a rare manifestation in hyperthyroidism. We describe the neurological manifestations of a 38 year old female with Graves' disease who developed peripheral neuropathy in the course of her treatment with propylthiouracil. After the drug was tapered off, the neurological signs disappeared. Therefore, we call attention for a possible toxic effect on peripheral nervous system caused by this drug.

  19. Toxicity of inhaled 90Sr fused clay particles in beagle dogs. V

    International Nuclear Information System (INIS)

    Snipes, M.B.; Boecker, B.B.; Hahn, F.F.; Hobbs, C.H.; Mauderly, J.L.; McClellan, R.O.; Pickrell, J.A.

    1974-01-01

    Studies on the metabolism, dosimetry, and biological effects of 90 Sr in fused clay particles in Beagle dogs have continued with a view toward defining the biological consequences of inhaling this important radionuclide in a relatively insoluble form. Seventy-two dogs were exposed to a polydisperse aerosol (AMAD 1.4 to 2.8 μm and sigma/sub g/ 1.4 to 2.7) of fused montmorillonite clay particles labeled with 90 Sr to achieve graded initial lung burdens (ILB) of 3.7 to 94 μCi/kg body weight; 12 control dogs were exposed to an aerosol of stable strontium in fused clay particles. These 84 dogs were assigned to the 90 Sr fused clay longevity study. An additional 26 dogs were exposed similarly (AMAD 1.9 to 2.5 μm and sigma/sub g/ 1.6 to 2.0) and assigned for sacrifice (Series II) at intervals after exposure to define metabolism and dosimetry of this aerosol in Beagle dogs. Of the 72 longevity dogs, 32 dogs having ILBs of 29 to 94 μCi/kg and cumulative doses to lung to death of 40,000 to 96,000 rads have died from radiation pneumonitis and/or pulmonary fibrosis from 159 to 477 days post-exposure. Fourteen dogs with ILBs of 15 to 36 μCi/kg and cumulative doses to lung to death of 34,000 to 68,000 rads have died from primary pulmonary hemangiosarcomas between 644 and 1214 days post-exposure. In addition, one dog developed a bronchiolo-alveolar carcinoma, another epidermoid carcinoma of the lung and a third, a squamous cell carcinoma in the nasal cavity. The remaining 26 exposed dogs and 12 controls of the longevity study are surviving at 1070 to 1707 days post-exposure. Dogs in the sacrifice series have been sacrificed to 1536 days post-exposure. (U.S.)

  20. Peripheral Neuropathy: Symptoms and Signs

    Science.gov (United States)

    ... Utah Research News Make a Difference Symptoms of Peripheral Neuropathy Print This Page Peripheral Neuropathy symptoms usually start ... more slowly over many years. The symptoms of peripheral neuropathy often include: A sensation of wearing an invisible “ ...

  1. Simple Syntheses of Two New Benzo-Fused Macrocycles Incorporating Chalcone Moiety.

    Science.gov (United States)

    Mondal, Rina; Samanta, Swati; Sarkar, Saheli; Mallik, Asok K

    2014-01-01

    Simple syntheses of the benzo-fused 26-membered macrocyclic bischalcone (19E,43E)-2.11.27.36-tetroxaheptacyclo[44.4.0.0(4,9).0(12,17).0(21,26).0(29,34).0(37,42)]pentaconta-1(46),4(9),5,7,12(17),13,15,19,21,23,25,29,31,33,37,39,41,43,47,49-icosaene-18,45-dione (3) and the benzo-fused 13-membered macrocyclic chalcone (19E)-2.11-dioxatetracyclo[19.4.0.0(4,9).0(12,17)]pentacosa-1(25),4(9),5,7,12(17),13,15,19,21,23-decaen-18-one (5) using very common starting materials and reagents are described. The compounds are new and they have been characterized from their analytical and spectral data.

  2. Donating Peripheral Blood Stem Cells

    Science.gov (United States)

    ... Print this page My Cart Donating peripheral blood stem cells Peripheral blood stem cell (PBSC) donation is a nonsurgical procedure to collect ... Donating bone marrow Donor experiences videos Peripheral blood stem cell (PBSC) donation is one of two methods of ...

  3. A Hybrid Color Mapping Approach to Fusing MODIS and Landsat Images for Forward Prediction

    OpenAIRE

    Chiman Kwan; Bence Budavari; Feng Gao; Xiaolin Zhu

    2018-01-01

    We present a new, simple, and efficient approach to fusing MODIS and Landsat images. It is well known that MODIS images have high temporal resolution and low spatial resolution, whereas Landsat images are just the opposite. Similar to earlier approaches, our goal is to fuse MODIS and Landsat images to yield high spatial and high temporal resolution images. Our approach consists of two steps. First, a mapping is established between two MODIS images, where one is at an earlier time, t1, and the...

  4. Dynamic behavior of aero-engine rotor with fusing design suffering blade off

    Directory of Open Access Journals (Sweden)

    Cun WANG

    2017-06-01

    Full Text Available Fan blade off (FBO from a running turbofan rotor will introduce sudden unbalance into the dynamical system, which will lead to the rub-impact, the asymmetry of rotor and a series of interesting dynamic behavior. The paper first presents a theoretical study on the response excited by sudden unbalance. The results reveal that the reaction force of the bearing located near the fan could always reach a very high value which may lead to the crush of ball, journal sticking, high stress on the other components and some other failures to endanger the safety of engine in FBO event. Therefore, the dynamic influence of a safety design named “fusing” is investigated by mechanism analysis. Meantime, an explicit FBO model is established to simulate the FBO event, and evaluate the effectiveness and potential dynamic influence of fusing design. The results show that the fusing design could reduce the vibration amplitude of rotor, the reaction force on most bearings and loads on mounts, but the sudden change of support stiffness induced by fusing could produce an impact effect which will couple with the influence of sudden unbalance. Therefore, the implementation of the design should be considered carefully with optimized parameters in actual aero-engine.

  5. The determination of UO2 and UF4 in fused fluoride salts

    International Nuclear Information System (INIS)

    Batiste, D.J.; Lee, D.A.

    1989-01-01

    The determination of uranium oxide solubilities in fused fluoride salts is important in the electrolytic preparation of uranium metal. This project was initiated to develop a method for the determination of UO 2 separately from UF 4 in UF 4 -CaF 2 -LiF fused salts. Previous methods used for the determination of UO 2 in fused fluoride salts involved inert gas fusions where oxygen was liberated as CO 2 , and hydrofluorination where oxygen was released as H 2 O; but the special equipment used for these procedures was no longer available. These methods assumed that all of the oxygen liberated was due to UO 2 and does not consider impurities from reagents and other oxygen sources that amount to a bias of approximately 0.3 wt %. This titrimetric method eliminates the bias by selectively extracting the UF 4 with a Na 2 EDTA-H 3 BO 3 solution. The remaining uranium oxide residue is treated and titrated gravimetrically to a potentiometric endpoint with NBS standard K 2 Cr 2 O 7 . An aliquot of the Na 2 EDTA-H 3 BO 3 extract is also titrated gravimetrically to a potentiometric endpoint, this uranium component is determined and calculated as UF 4 . 4 refs., 2 figs., 2 tabs

  6. Reversible thermal fusing model of carbon black current-limiting thermistors

    International Nuclear Information System (INIS)

    Martin, James E.; Heaney, Michael B.

    2000-01-01

    Composites of carbon black particles in polyethylene exhibit an unusually rapid increase in resistivity as the applied electric field is increased, making this material commercially useful as current-limiting thermistors, also known as automatically resettable fuses. In this application the composite is in series with the circuit it is protecting: at low applied voltages the circuit is the load, but at high applied voltages the composite becomes the load, limiting the current to the circuit. We present a simple model of this behavior in terms of a network of nonlinear resistors. Each resistor has a resistance that depends explicitly and reversibly on its instantaneous power dissipation. This model predicts that in the soft fusing, or current-limiting, regime, where the current through the composite decreases with increasing voltage, a platelike dissipation instability develops normal to the applied field, in agreement with experimental observations, which is solely due to fluctuations in the microstructure

  7. Iterative Bayesian Estimation of Travel Times on Urban Arterials: Fusing Loop Detector and Probe Vehicle Data.

    Science.gov (United States)

    Liu, Kai; Cui, Meng-Ying; Cao, Peng; Wang, Jiang-Bo

    2016-01-01

    On urban arterials, travel time estimation is challenging especially from various data sources. Typically, fusing loop detector data and probe vehicle data to estimate travel time is a troublesome issue while considering the data issue of uncertain, imprecise and even conflicting. In this paper, we propose an improved data fusing methodology for link travel time estimation. Link travel times are simultaneously pre-estimated using loop detector data and probe vehicle data, based on which Bayesian fusion is then applied to fuse the estimated travel times. Next, Iterative Bayesian estimation is proposed to improve Bayesian fusion by incorporating two strategies: 1) substitution strategy which replaces the lower accurate travel time estimation from one sensor with the current fused travel time; and 2) specially-designed conditions for convergence which restrict the estimated travel time in a reasonable range. The estimation results show that, the proposed method outperforms probe vehicle data based method, loop detector based method and single Bayesian fusion, and the mean absolute percentage error is reduced to 4.8%. Additionally, iterative Bayesian estimation performs better for lighter traffic flows when the variability of travel time is practically higher than other periods.

  8. Fusing inertial sensor data in an extended Kalman filter for 3D camera tracking.

    Science.gov (United States)

    Erdem, Arif Tanju; Ercan, Ali Özer

    2015-02-01

    In a setup where camera measurements are used to estimate 3D egomotion in an extended Kalman filter (EKF) framework, it is well-known that inertial sensors (i.e., accelerometers and gyroscopes) are especially useful when the camera undergoes fast motion. Inertial sensor data can be fused at the EKF with the camera measurements in either the correction stage (as measurement inputs) or the prediction stage (as control inputs). In general, only one type of inertial sensor is employed in the EKF in the literature, or when both are employed they are both fused in the same stage. In this paper, we provide an extensive performance comparison of every possible combination of fusing accelerometer and gyroscope data as control or measurement inputs using the same data set collected at different motion speeds. In particular, we compare the performances of different approaches based on 3D pose errors, in addition to camera reprojection errors commonly found in the literature, which provides further insight into the strengths and weaknesses of different approaches. We show using both simulated and real data that it is always better to fuse both sensors in the measurement stage and that in particular, accelerometer helps more with the 3D position tracking accuracy, whereas gyroscope helps more with the 3D orientation tracking accuracy. We also propose a simulated data generation method, which is beneficial for the design and validation of tracking algorithms involving both camera and inertial measurement unit measurements in general.

  9. Deep reactive ion etching of fused silica using a single-coated soft mask layer for bio-analytical applications

    International Nuclear Information System (INIS)

    Ray, Tathagata; Zhu, Haixin; Meldrum, Deirdre R

    2010-01-01

    In this note, we present our results from process development and characterization of reactive ion etching (RIE) of fused silica using a single-coated soft masking layer (KMPR® 1025, Microchem Corporation, Newton, MA). The effects of a number of fluorine-radical-based gaseous chemistries, the gas flow rate, RF power and chamber pressure on the etch rate and etching selectivity of fused silica were studied using factorial experimental designs. RF power and pressure were found to be the most important factors in determining the etch rate. The highest fused silica etch rate obtained was about 933 Å min −1 by using SF 6 -based gas chemistry, and the highest etching selectivity between the fused silica and KMPR® 1025 was up to 1.2 using a combination of CF 4 , CHF 3 and Ar. Up to 30 µm deep microstructures have been successfully fabricated using the developed processes. The average area roughness (R a ) of the etched surface was measured and results showed it is comparable to the roughness obtained using a wet etching technique. Additionally, near-vertical sidewalls (with a taper angle up to 85°) have been obtained for the etched microstructures. The processes developed here can be applied to any application requiring fabrication of deep microstructures in fused silica with near-vertical sidewalls. To our knowledge, this is the first note on deep RIE of fused silica using a single-coated KMPR® 1025 masking layer and a non-ICP-based reactive ion etcher. (technical note)

  10. Comparative effects of inhaled relatively insoluble forms of 90Y, 144Ce, and 90Sr on canine peripheral lymphocyte function

    International Nuclear Information System (INIS)

    Benjamin, S.A.; Jones, R.K.; Snipes, M.B.; Lustgarten, C.S.

    1976-01-01

    Dogs that have inhaled relatively insoluble forms of either alpha- or beta-emitting radionuclides manifest a peripheral lymphopenia, the development and course of which depends on both total dose and dose rate. The remaining peripheral lymphocytes in dogs exposed to longer lived beta-emitting radionuclides showed a depressed function as measured by the ability to respond to plant mitogens in vitro. This experiment was designed to evaluate the effect of dose rate on peripheral lymphocyte function by exposing dogs to aerosols of radionuclides with varied effective half-lives in the lung: 90 Y (2.6 days), 144 Ce (170 days), and 90 Sr (650 days). Three groups of four adult beagle dogs each were exposed by inhalation to 90 Y, 144 Ce, or 90 Sr in fused-clay particles. Two controls were matched with each group. Initial lung burdens and initial dose rates to the lung were 520 to 610 μCi/kg of body weight and 2200 to 2600 rads/day in the 90 Y group, 33 to 60 μCi/kg and 200 to 350 rads/day in the 144 Ce group, and 25 to 32 μCi/kg and 130 to 170 rads/day in the 90 Sr group. Hematologic parameters and lymphocyte function as measured by the ability of lymphocytes to respond to plant mitogen stimulation were evaluated on a weekly or biweekly basis for 8 weeks after exposure and on a monthly basis thereafter. The 90 Y-exposed dogs showed a marked lymphopenia within 1 week with a return to control levels by 20 weeks after exposure. The remaining peripheral lymphocytes, however, showed no functional changes in these dogs. Animals exposed to 144 Ce or 90 Sr developed a progressive and persisent lymphopenia and showed functional depression of the remaining lymphocytes as well. The relationships among dose pattern, lymphopenia, and lymphocyte-function depression are discussed

  11. Laser-Induced Damage Growth on Larger-Aperture Fused Silica Optical Components at 351 nm

    International Nuclear Information System (INIS)

    Wan-Qing, Huang; Wei, Han; Fang, Wang; Yong, Xiang; Fu-Quan, Li; Bin, Feng; Feng, Jing; Xiao-Feng, Wei; Wan-Guo, Zheng; Xiao-Min, Zhang

    2009-01-01

    Laser-induced damage is a key lifetime limiter for optics in high-power laser facility. Damage initiation and growth under 351 nm high-fluence laser irradiation are observed on larger-aperture fused silica optics. The input surface of one fused silica component is damaged most severely and an explanation is presented. Obscurations and the area of a scratch on it are found to grow exponentially with the shot number. The area of damage site grows linearly. Micrographs of damage sites support the micro-explosion damage model which could be used to qualitatively explain the phenomena

  12. Tumors of peripheral nerves

    International Nuclear Information System (INIS)

    Ho, Michael; Lutz, Amelie M.

    2017-01-01

    Differentiation between malignant and benign tumors of peripheral nerves in the early stages is challenging; however, due to the unfavorable prognosis of malignant tumors early identification is required. To show the possibilities for detection, differential diagnosis and clinical management of peripheral nerve tumors by imaging appearance in magnetic resonance (MR) neurography. Review of current literature available in PubMed and MEDLINE, supplemented by the authors' own observations in clinical practice. Although not pathognomonic, several imaging features have been reported for a differentiation between distinct peripheral nerve tumors. The use of MR neurography enables detection and initial differential diagnosis in tumors of peripheral nerves. Furthermore, it plays an important role in clinical follow-up, targeted biopsy and surgical planning. (orig.) [de

  13. Polarizing beam splitter of deep-etched triangular-groove fused-silica gratings.

    Science.gov (United States)

    Zheng, Jiangjun; Zhou, Changhe; Feng, Jijun; Wang, Bo

    2008-07-15

    We investigated the use of a deep-etched fused-silica grating with triangular-shaped grooves as a highly efficient polarizing beam splitter (PBS). A triangular-groove PBS grating is designed at a wavelength of 1550 nm to be used in optical communication. When it is illuminated in Littrow mounting, the transmitted TE- and TM-polarized waves are mainly diffracted in the minus-first and zeroth orders, respectively. The design condition is based on the average differences of the grating mode indices, which is verified by using rigorous coupled-wave analysis. The designed PBS grating is highly efficient over the C+L band range for both TE and TM polarizations (>97.68%). It is shown that such a triangular-groove PBS grating can exhibit a higher diffraction efficiency, a larger extinction ratio, and less reflection loss than the binary-phase fused-silica PBS grating.

  14. Tree Classification with Fused Mobile Laser Scanning and Hyperspectral Data

    Science.gov (United States)

    Puttonen, Eetu; Jaakkola, Anttoni; Litkey, Paula; Hyyppä, Juha

    2011-01-01

    Mobile Laser Scanning data were collected simultaneously with hyperspectral data using the Finnish Geodetic Institute Sensei system. The data were tested for tree species classification. The test area was an urban garden in the City of Espoo, Finland. Point clouds representing 168 individual tree specimens of 23 tree species were determined manually. The classification of the trees was done using first only the spatial data from point clouds, then with only the spectral data obtained with a spectrometer, and finally with the combined spatial and hyperspectral data from both sensors. Two classification tests were performed: the separation of coniferous and deciduous trees, and the identification of individual tree species. All determined tree specimens were used in distinguishing coniferous and deciduous trees. A subset of 133 trees and 10 tree species was used in the tree species classification. The best classification results for the fused data were 95.8% for the separation of the coniferous and deciduous classes. The best overall tree species classification succeeded with 83.5% accuracy for the best tested fused data feature combination. The respective results for paired structural features derived from the laser point cloud were 90.5% for the separation of the coniferous and deciduous classes and 65.4% for the species classification. Classification accuracies with paired hyperspectral reflectance value data were 90.5% for the separation of coniferous and deciduous classes and 62.4% for different species. The results are among the first of their kind and they show that mobile collected fused data outperformed single-sensor data in both classification tests and by a significant margin. PMID:22163894

  15. Greyish shadow on the labial gingival margin after insertion porcelain fused to metal crown on anterior teeth

    Directory of Open Access Journals (Sweden)

    Ike Damayanti Habar

    2016-06-01

    Full Text Available The crown is the type of restoration that replaces lost tooth structure caused by caries, trauma, or other causes which aims to restore comfort, function and patient confidence. Porcelain fused to metal restorationis an option that dominate the aesthetic restoration crown sand fixed prosthesisover the last 50 years. Porcelain fused to metal crown, consists of porcelain layer bonded to a thin cast metal coping that fits over the tooth preparation. Such a restoration combines the strength  and accurate fit of a cast metal crown with  the cosmetic effect of a porcelain crown. In some cases, it looks greyish shadow on the labial gingival margin after insertion porcelain fused to metal crowns on anterior teeth that can not be hidden even if the placement of the edge in subgingival. The purpose of this case report is to determine the cause of a greyish shadow on the labial gingival margin after insertion porcelain fused to metal crowns on anterior teeth and how to prevent a greyish shadow very disturbing aesthetics of the patient.

  16. Single-Molecule Imaging of DNAs with Sticky Ends at Water/Fused Silica Interface

    Energy Technology Data Exchange (ETDEWEB)

    Isailovic, Slavica [Iowa State Univ., Ames, IA (United States)

    2005-01-01

    Total internal reflection fluorescence microscopy (TIRFM) was used to study intermolecular interactions of DNAs with unpaired (sticky) ends of different lengths at water/fused silica interface at the single-molecule level. Evanescent field residence time, linear velocity and adsorption/desorption frequency were measured in a microchannel for individual DNA molecules from T7, Lambda, and PSP3 phages at various pH values. The longest residence times and the highest adsorption/desorption frequencies at the constant flow at pH 5.5 were found for PSP3 DNA, followed by lower values for Lambda DNA, and the lowest values for T7 DNA. Since T7, Lambda, and PSP3 DNA molecules contain none, twelve and nineteen unpaired bases, respectively, it was concluded that the affinity of DNAs for the surface increases with the length of the sticky ends. This confirms that hydrophobic and hydrogen-bonding interactions between sticky ends and fused-silica surface are driving forces for DNA adsorption at the fused-silica surface. Described single-molecule methodology and results therein can be valuable for investigation of interactions in liquid chromatography, as well as for design of DNA hybridization sensors and drug delivery systems.

  17. Peripheral dentinogenic ghost cell tumor

    Directory of Open Access Journals (Sweden)

    Sushant S Kamat

    2013-01-01

    Full Text Available Dentinogenic ghost cell tumors (DGCT are uncommon lesions mainly with rare peripheral types. This report presents a case of peripheral DGCT on the left side of the mandibular alveolar ridge of a heavy smoker, a 68-year-old man, with main presenting feature as a mild pain. Submandibular lymphadenopathy and radiological "saucerization" were evident. Differential diagnosis included fibroma, neurofibroma, peripheral ameloblastoma, peripheral odontogenic fibroma, and peripheral giant cell granuloma. Histologically, ameloblastoma-like epithelial elements were seen in association with grouped ghost cells. Proliferating polyhedral cells and stellate reticulum-like cells with various densities were spread over a wide range of the field. The lesion was curetted and after 2 years of follow up, it did not recur.

  18. An unusual cause of chest pain: Fused cervical vertebra (C3-C4

    Directory of Open Access Journals (Sweden)

    Daipayan Chatterjee

    2014-01-01

    Full Text Available Cervicogenic angina is paroxysmal precordialgia usually due to lower cervical vertebral involvement. But upper cervical vertebral segmental anomaly causing cervicogenic angina is rare. Herein, we report a case of cervicogenic angina due to fused 3 rd and 4 th cervical vertebra in a 37-year female, which was initially misdiagnosed as angina and treated likewise. But, persistence of symptoms led to evaluation of her cervical spine and subsequent diagnosis. Cervical traction, physiotherapy and posture training relieved her of her symptoms with no recurrence till 6 months of follow-up. Fused C3-C4 can be a cause of precordialgia and physicians should be aware of it.

  19. Synthesis of pyrido[1,2-a]benzimidazoles and other fused imidazole derivatives with a bridgehead nitrogen atom

    Science.gov (United States)

    Begunov, Roman S.; Ryzvanovich, Galina A.

    2013-01-01

    Main methods for the synthesis of fused imidazole derivatives with a bridgehead nitrogen atom are systematically considered and summarized. The reaction mechanisms that underlie the methods for the synthesis of pyrido[1,2-a]benzimidazoles and related compounds are described. Biological properties and mechanisms of the biological activity of fused azaheterocycles are discussed. The bibliography includes 152 references.

  20. Endodontic management of a mandibular third molar fused with a fourth molar.

    Science.gov (United States)

    Turell, I L; Zmener, O

    1999-05-01

    Developmental anomalies in permanent molars frequently require surgical intervention. A case of a mandibular third molar fused with a fourth molar which was successfully treated with conservative endodontic therapy is reported.

  1. Synthesis and properties of nitrogenous heterocycles containing a spiro-fused cyclopropane fragment

    International Nuclear Information System (INIS)

    Tomilov, Yury V; Nefedov, Oleg M; Kostyuchenko, Irina V

    2000-01-01

    The published data on the methods of synthesis and chemical transformations of nitrogenous heterocyclic compounds spiro-fused with a cyclopropane fragment are described systematically and generalised. The bibliography includes 146 references.

  2. Beauty and cuteness in peripheral vision

    Science.gov (United States)

    Kuraguchi, Kana; Ashida, Hiroshi

    2015-01-01

    Guo et al. (2011) showed that attractiveness was detectable in peripheral vision. Since there are different types of attractiveness (Rhodes, 2006), we investigated how beauty and cuteness are detected in peripheral vision with a brief presentation. Participants (n = 45) observed two Japanese female faces for 100 ms, then were asked to respond which face was more beautiful (or cuter). The results indicated that both beauty and cuteness were detectable in peripheral vision, but not in the same manner. Discrimination rates for judging beauty were invariant in peripheral and central vision, while discrimination rates for judging cuteness declined in peripheral vision as compared with central vision. This was not explained by lower resolution in peripheral vision. In addition, for male participants, it was more difficult to judge cuteness than beauty in peripheral vision, thus suggesting that gender differences can have a certain effect when judging cuteness. Therefore, central vision might be suitable for judging cuteness while judging beauty might not be affected by either central or peripheral vision. This might be related with the functional difference between beauty and cuteness. PMID:25999883

  3. Quinone-fused porphyrins as contrast agents for photoacoustic imaging

    KAUST Repository

    Banala, Srinivas

    2017-06-27

    Photoacoustic (PA) imaging is an emerging non-invasive diagnostic modality with many potential clinical applications in oncology, rheumatology and the cardiovascular field. For this purpose, there is a high demand for exogenous contrast agents with high absorption coefficients in the optical window for tissue imaging, i.e. the near infrared (NIR) range between 680 and 950 nm. We herein report the photoacoustic properties of quinone-fused porphyrins inserted with different transition metals as new highly promising candidates. These dyes exhibit intense NIR absorption, a lack of fluorescence emission, and PA sensitivity in concentrations below 3 nmol mL. In this context, the highest PA signal was obtained with a Zn(ii) inserted dye. Furthermore, this dye was stable in blood serum and free thiol solution and exhibited negligible cell toxicity. Additionally, the Zn(ii) probe could be detected with an up to 3.2 fold higher PA intensity compared to the clinically most commonly used PA agent, ICG. Thus, further exploration of the \\'quinone-fusing\\' approach to other chromophores may be an efficient way to generate highly potent PA agents that do not fluoresce and shift their absorption into the NIR range.

  4. Distribution and Orientation of Carbon Fibers in Polylactic Acid Parts Produced by Fused Deposition Modeling

    DEFF Research Database (Denmark)

    Hofstätter, Thomas; W. Gutmann, Ingomar; Koch, Thomas

    2016-01-01

    The aim of this paper is the understanding of the fiber orientation by investigations in respect to the inner configuration of a polylactic acid matrix reinforced with short carbon fibers after a fused deposition modeling extrusion process. The final parts were analyzed by X-ray, tomography......, and magnetic resonance imaging allowing a resolved orientation of the fibers and distribution within the part. The research contributes to the understanding of the fiber orientation and fiber reinforcement of fused deposition modeling parts in additive manufacturing....

  5. Tetrakis(4-tert-butylphenyl) substituted and fused quinoidal porphyrins

    KAUST Repository

    Zeng, Wangdong

    2012-01-01

    4-tert-Butylphenyl-substituted and fused quinoidal porphyrins 1 and 2 are prepared for the first time. They show (1) intense one-photon absorption in the far-red/near-infrared region, (2) enhanced two-photon absorption compared with aromatic porphyrin monomers, and (3) amphoteric redox behavior. Their geometry and electronic structure are studied by DFT calculations. This journal is © 2012 The Royal Society of Chemistry.

  6. Fracture and Fatigue Resistance of Cemented versus Fused CAD-on Veneers over Customized Zirconia Implant Abutments.

    Science.gov (United States)

    Nossair, Shereen Ahmed; Aboushelib, Moustafa N; Morsi, Tarek Salah

    2015-01-05

    To evaluate the fracture mechanics of cemented versus fused CAD-on veneers on customized zirconia implant abutments. Forty-five identical customized CAD/CAM zirconia implant abutments (0.5 mm thick) were prepared and seated on short titanium implant abutments (Ti base). A second scan was made to fabricate 45 CAD-on veneers (IPS Empress CAD, A2). Fifteen CAD-on veneers were cemented on the zirconia abutments (Panavia F2.0). Another 15 were fused to the zirconia abutments using low-fusing glass, while manually layered veneers served as control (n = 15). The restorations were subjected to artificial aging (3.2 million cycles between 5 and 10 kg in a water bath at 37°C) before being axially loaded to failure. Fractured specimens were examined using scanning electron microscopy to detect fracture origin, location, and size of critical crack. Stress at failure was calculated using fractography principles (alpha = 0.05). Cemented CAD-on restorations demonstrated significantly higher (F = 72, p CAD-on and manually layered restorations. Fractographic analysis of fractured specimens indicated that cemented CAD-on veneers failed due to radial cracks originating from the veneer/resin interface. Branching of the critical crack was observed in the bulk of the veneer. Fused CAD-on veneers demonstrated cohesive fracture originating at the thickest part of the veneer ceramic, while manually layered veneers failed due to interfacial fracture at the zirconia/veneer interface. Within the limitations of this study, cemented CAD-on veneers on customized zirconia implant abutments demonstrated higher fracture than fused and manually layered veneers. © 2014 by the American College of Prosthodontists.

  7. Ball driven type MEMS SAD for artillery fuse

    International Nuclear Information System (INIS)

    Seok, Jin Oh; Jeong, Ji-hun; Eom, Junseong; Lee, Seung S; Lee, Chun Jae; Ryu, Sung Moon; Oh, Jong Soo

    2017-01-01

    The SAD (safety and arming device) is an indispensable fuse component that ensures safe and reliable performance during the use of ammunition. Because the application of electronic devices for smart munitions is increasing, miniaturization of the SAD has become one of the key issues for next-generation artillery fuses. Based on MEMS technology, various types of miniaturized SADs have been proposed and fabricated. However, none of them have been reported to have been used in actual munitions due to their lack of high impact endurance and complicated explosive train arrangements. In this research, a new MEMS SAD using a ball driven mechanism, is successfully demonstrated based on a UV LIGA (lithography, electroplating and molding) process. Unlike other MEMS SADs, both high impact endurance and simple structure were achieved by using a ball driven mechanism. The simple structural design also simplified the fabrication process and increased the processing yield. The ball driven type MEMS SAD performed successfully under the desired safe and arming conditions of a spin test and showed fine agreement with the FEM simulation result, conducted prior to its fabrication. A field test was also performed with a grenade launcher to evaluate the SAD performance in the firing environment. All 30 of the grenade samples equipped with the proposed MEMS SAD operated successfully under the high-G setback condition. (paper)

  8. Ball driven type MEMS SAD for artillery fuse

    Science.gov (United States)

    Seok, Jin Oh; Jeong, Ji-hun; Eom, Junseong; Lee, Seung S.; Lee, Chun Jae; Ryu, Sung Moon; Oh, Jong Soo

    2017-01-01

    The SAD (safety and arming device) is an indispensable fuse component that ensures safe and reliable performance during the use of ammunition. Because the application of electronic devices for smart munitions is increasing, miniaturization of the SAD has become one of the key issues for next-generation artillery fuses. Based on MEMS technology, various types of miniaturized SADs have been proposed and fabricated. However, none of them have been reported to have been used in actual munitions due to their lack of high impact endurance and complicated explosive train arrangements. In this research, a new MEMS SAD using a ball driven mechanism, is successfully demonstrated based on a UV LIGA (lithography, electroplating and molding) process. Unlike other MEMS SADs, both high impact endurance and simple structure were achieved by using a ball driven mechanism. The simple structural design also simplified the fabrication process and increased the processing yield. The ball driven type MEMS SAD performed successfully under the desired safe and arming conditions of a spin test and showed fine agreement with the FEM simulation result, conducted prior to its fabrication. A field test was also performed with a grenade launcher to evaluate the SAD performance in the firing environment. All 30 of the grenade samples equipped with the proposed MEMS SAD operated successfully under the high-G setback condition.

  9. Hepatic abscess versus peripheral cholangiocarcinoma: Sonographic differentiation

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hwan Hoon; Kim, Yun Hwan; Kang, Chang Ho; Chung, Kyoo Byung; Suh, Won Hyuck [Korea University College of Medicine, Seoul (Korea, Republic of); Lee, Chang Hee [Kunkuk University College of Medicine, Chung-Ju Hospital, Chung-Ju (Korea, Republic of)

    2000-12-15

    To find out the sonographic findings that are useful to differentiate hepatic abscess from peripheral cholangiocarcinoma. Twenty-two hepatic abscesses and 22 peripheral cholangiocarcinomas which had been confirmed histologically were included in this study. Objective points were echo characteristics of the lesion, internal septation, presence of peripheral low echoic rim, demarcation from normal liver(well or poorly defined), posterior enhancement, multiplicity, dilatation of bile duct(obstructive or non-obstructive), intrahepatic duct stone, pleural effusion, and intra-abdominal fluid collection. Echo characteristics of the lesion were classified in-to four types. Type I; Predominantly echogenic with hypoechoic portion, type II; Echogenic without hypoechoic portion, type III; Predominantly hypoechoic with echogenic portion, type IV; Hypoechoic without echogenic portion. 1)Nine abscesses and 2 peripheral cholangiocarcinomas were type I(p=0.037), 2)One abscess and 18 peripheral cholangiocarcinomas were type II(p=0.001), 3)Seven abscesses and none of peripheral cholangiocarcinomas were type III(p=0.001), 4)Five abscesses and 2 peripheral cholangiocarcinomas were type IV(p=0.410). Only 7 abscesses showed internal septations(p=0.013). One abscess and 9 peripheral cholangiocarcinomas showed peripheral hypoechoic halos(p=0.012). Only 9 peripheral cholangiocarcinomas showed obstructive bile duct dilatation (p=0.001). There were no statistically significant differences between abscess and peripheral cholangiocarcinoma on other objective points. Predominantly echogenic with hypoechoic portion, predominantly hypoechoic with echogenic portion, and internal septation are the features suggestive of hepatic abscess, and echogenic without hypoechoic portion, peripheral hypoechoic halo, obstructive bile duct dilatation are suggestive of peripheral cholangiocarcinoma. Therefore these sonographic findings are helpful to differentiate hepatic abscess from peripheral

  10. BaroFuse, a novel pressure-driven, adjustable-throughput perfusion system for tissue maintenance and assessment

    Directory of Open Access Journals (Sweden)

    Austin Rountree

    2016-12-01

    Conclusions: The very low flow rates and simplicity of design and operation of the BaroFuse device allow for the efficient generation of large number of kinetic profiles in OCR and other endpoints lasting from hours to days. The use of flow enhances the ability to make measurements on primary tissue where some elements of native three-dimensional structure are preserved. We offer the BaroFuse as a powerful tool for physiological studies and for pharmaceutical assessment of drug effects as well as personalized medicine.

  11. Controllable damping of high-Q violin modes in fused silica suspension fibers

    Science.gov (United States)

    Dmitriev, A. V.; Mescheriakov, S. D.; Tokmakov, K. V.; Mitrofanov, V. P.

    2010-01-01

    Fused silica fiber suspension of the test masses will be used in the interferometric gravitational wave detectors of the next generation. This allows a significant reduction of losses in the suspension and thermal noise associated with the suspension. Unfortunately, unwanted violin modes may be accidentally excited in the suspension fibers. The Q-factor of the violin modes also exceeds 108. They have a ring-down time that is too long and may complicate the stable control of the interferometer. Results of the investigation of a violin mode active damping system are described. An original sensor and actuator were especially developed to realize the effective coupling of a thin, optically transparent, non-conducting fused silica fiber with an electric circuit. The damping system allowed the changing of the violin mode's damping rate over a wide range.

  12. Synthesis of zeolite NaA membrane from fused fly ash extract

    CSIR Research Space (South Africa)

    Ameh, AE

    2016-01-01

    Full Text Available Zeolite-NaA membranes were synthesized from an extract of fused South African fly ash on a porous titanium support by a secondary growth method. The influence of the synthesis molar regime on the formation of zeolite NaA membrane layer...

  13. Effects of 3D microlens transfer into fused silica substrate by CF{sub 4}/O{sub 2} dry etching

    Energy Technology Data Exchange (ETDEWEB)

    Grigaliūnas, Viktoras, E-mail: Viktoras.Grigaliunas@ktu.lt [Institute of Materials Science, Kaunas University of Technology, Barsausko 59, LT-51423 Kaunas (Lithuania); Jucius, Dalius; Lazauskas, Algirdas; Andrulevičius, Mindaugas; Sakaliūnienė, Jolita; Abakevičienė, Brigita; Kopustinskas, Vitoldas [Institute of Materials Science, Kaunas University of Technology, Barsausko 59, LT-51423 Kaunas (Lithuania); Smetona, Saulius [Qorvo, 7628 Thorndike Road Greensboro, NC 27409 United States (United States); Tamulevičius, Sigitas [Institute of Materials Science, Kaunas University of Technology, Barsausko 59, LT-51423 Kaunas (Lithuania)

    2017-01-30

    Highlights: • The etching rate of PMMA is dependent on the plasma etching time. • The etching rate ratio between PMMA and fused silica vary during plasma treatment. • The etching rate ratio variation must be assessed during the microlens design phase. - Abstract: Nowadays, 3D microoptical elements find a variety of applications from light emitting diodes and household appliances to precise medical endoscopes. Such elements, fabricated in a fused silica substrate by combining 3D e-beam patterning and dry etching, can be used as a mold for the high throughput replication in polymeric materials by UV nanoimprint technique. Flexible and precise control of 3D shape in the resist layer can be achieved by e-beam patterning, but it is also very important to know peculiarities of 3D pattern transfer from resist layer into the fused silica substrate. This paper reports on the effects of PMMA 3D microlens pattern transfer into fused silica substrate by CF{sub 4}/O{sub 2} dry etching. It is demonstrated that etching rate ratio between PMMA and fused silica changes during plasma treatment. Thus, the resulting shape of transferred 3D profile is different from the shape in PMMA and this variation must be assessed during the design phase.

  14. Pattern transfer on fused silica samples using sub-aperture reactive ion beam etching

    Energy Technology Data Exchange (ETDEWEB)

    Miessler, Andre; Arnold, Thomas [Leibniz-Institut fuer Oberflaechenmodifizierung (IOM), Permoserstrasse 15, D-04318 Leipzig (Germany)

    2012-07-01

    In comparison to sole Ar ion beam sputtering Reactive Ion Beam Etching (RIBE) reveals the main advantage of increasing the selectivity for different kind of materials due to chemical contributions during the material removal. Therefore RIBE is qualified to be an excellent candidate for pattern transfer applications. The goal of the present study is to apply a sub-aperture reactive ion beam for pattern transfer on large fused silica samples. Concerning this matter, the etching behavior in the ion beam periphery plays a decisive role. Using a Kaufman-typed ion source with NF{sub 3} as reactive gas, XPS measurements of the modified surface exposes impurities like Ni, Fe and Cr, which belongs to chemically eroded material of the plasma pot and a layer formation of silicon nitride, handicaps the etching process mainly in the beam periphery where the sputtering contribution decrease. These side effects influence the pattern transfer of trench structures, produced in AZ MIR 701 photoresist by lithography on a 2'' fused silica plate, by changing the selectivity due to modified chemical reactions of the resist layer. Concerning this we investigate a RF-Ion source for sub aperture reactive ion beam applications and finally we examine the pattern transfer on large fused silica plates using NF{sub 3}-sub-aperture RIBE.

  15. Shoulder balance in Lenke type 2 adolescent idiopathic scoliosis: Should we fuse to the second thoracic vertebra?

    Science.gov (United States)

    Yang, Huiliang; Im, Gi Hye; Hu, Bowen; Wang, Lei; Zhou, Chunguang; Liu, Limin; Song, Yueming

    2017-12-01

    There are many different systems recommending upper instrumented vertebra (UIV) for Lenke type 2 adolescent idiopathic scoliosis (AIS), several of which suggest that all Lenke type 2 AIS patients should be fused to the second thoracic vertebra (T2). However, all previously proposed UIV selecting systems do not accurately predict postoperative shoulder balance. We investigated whether fusing to T2 could prevent postoperative shoulder imbalance and identified circumstances under which to fuse up to T2. We retrospectively collected all patients with typical Lenke type 2 AIS who received surgery by one spine surgeon in our hospital from 2010 to 2014. Lateral shoulder balance was assessed utilizing radiographic shoulder height difference (RSH), coracoid height difference (CHD), clavicle-rib intersection difference (CRID), and clavicle angle (CA). Medial shoulder balance was assessed by T1 tilt angle and first rib angle (FRA). Lateral shoulders were considered to be level if the absolute value of RSH was less than 10 millimeters. All patients were divided into two groups as follows: 1) T2 group: UIV of T2 (n=49); and 2) below-T2 group: UIV of T3 (n=24) or T4 (n=6). Patients were assessed before surgery and at final follow-up with a minimum follow-up duration of 24 months. Seventy-nine typical Lenke type 2 AIS patients were identified. Preoperative CHD and CA were significantly associated with postoperative lateral shoulder imbalance (both p=0.045), whereas the UIV level was not significantly associated with it. Both fusing to T2 and to below T2 could improve RSH (pbalance parameters (p=0.042, pbalance, fusing to below T2 worsened T1 tilt angle and FRA at last follow-up (p=0.025 and pbalance. In addition, for patients with an elevated left border of T1, the T2 group had worse preoperative T1 tilt angle but gained better postoperative T1 tilt angle than the below-T2 group (pbalance, more so than the UIV level, can strongly influence postoperative lateral shoulder balance

  16. Compositional characterization of sintered (U,Th)O2 pellets by EDXRF using fused bead specimens

    International Nuclear Information System (INIS)

    Sanjay Kumar, S.; Dhara, Sangita; Misra, N.L.; Aggarwal, S.K.

    2015-01-01

    Fused bead specimens were used for analyzing sintered (U,Th)O 2 pellets by Energy Dispersive X-Ray Fluorescence (EDXRF) spectrometry. The bead specimens of calibration mixtures U 3 O 8 and ThO 2 were made by fusing them in Lithium Tetraborate/Metaborate fusion mixtures using a fusion bead machine. The EDXRF spectra of these beads were used for making calibration plot for U% determination in (U+Th) amounts. Using these calibration plots and EDXRF spectra of bead of sintered (U,Th)O 2 pellets, U% in these pellets was successfully determined. (author)

  17. Feasibility and limitations of anti-fuses based on bistable non-volatile switches for power electronic applications

    Science.gov (United States)

    Erlbacher, T.; Huerner, A.; Bauer, A. J.; Frey, L.

    2012-09-01

    Anti-fuse devices based on non-volatile memory cells and suitable for power electronic applications are demonstrated for the first time using silicon technology. These devices may be applied as stand alone devices or integrated using standard junction-isolation into application-specific and smart-power integrated circuits. The on-resistance of such devices can be permanently switched by nine orders of magnitude by triggering the anti-fuse with a positive voltage pulse. Extrapolation of measurement data and 2D TCAD process and device simulations indicate that 20 A anti-fuses with 10 mΩ can be reliably fabricated in 0.35 μm technology with a footprint of 2.5 mm2. Moreover, this concept offers distinguished added-values compared to existing mechanical relays, e.g. pre-test, temporary and permanent reset functions, gradual turn-on mode, non-volatility, and extendibility to high voltage capability.

  18. Deep Hashing Based Fusing Index Method for Large-Scale Image Retrieval

    Directory of Open Access Journals (Sweden)

    Lijuan Duan

    2017-01-01

    Full Text Available Hashing has been widely deployed to perform the Approximate Nearest Neighbor (ANN search for the large-scale image retrieval to solve the problem of storage and retrieval efficiency. Recently, deep hashing methods have been proposed to perform the simultaneous feature learning and the hash code learning with deep neural networks. Even though deep hashing has shown the better performance than traditional hashing methods with handcrafted features, the learned compact hash code from one deep hashing network may not provide the full representation of an image. In this paper, we propose a novel hashing indexing method, called the Deep Hashing based Fusing Index (DHFI, to generate a more compact hash code which has stronger expression ability and distinction capability. In our method, we train two different architecture’s deep hashing subnetworks and fuse the hash codes generated by the two subnetworks together to unify images. Experiments on two real datasets show that our method can outperform state-of-the-art image retrieval applications.

  19. Peripheral visual performance enhancement by neurofeedback training.

    Science.gov (United States)

    Nan, Wenya; Wan, Feng; Lou, Chin Ian; Vai, Mang I; Rosa, Agostinho

    2013-12-01

    Peripheral visual performance is an important ability for everyone, and a positive inter-individual correlation is found between the peripheral visual performance and the alpha amplitude during the performance test. This study investigated the effect of alpha neurofeedback training on the peripheral visual performance. A neurofeedback group of 13 subjects finished 20 sessions of alpha enhancement feedback within 20 days. The peripheral visual performance was assessed by a new dynamic peripheral visual test on the first and last training day. The results revealed that the neurofeedback group showed significant enhancement of the peripheral visual performance as well as the relative alpha amplitude during the peripheral visual test. It was not the case in the non-neurofeedback control group, which performed the tests within the same time frame as the neurofeedback group but without any training sessions. These findings suggest that alpha neurofeedback training was effective in improving peripheral visual performance. To the best of our knowledge, this is the first study to show evidence for performance improvement in peripheral vision via alpha neurofeedback training.

  20. Textiles: Some technocal information and data VI: fusing

    CSIR Research Space (South Africa)

    Cawood, MP

    1980-09-01

    Full Text Available only one month is reauired to train an oDerator for fusing whereas 4 - 6 monthsare - - -- - necessary f i r sewing machine bperatod. 3. Higher production rates and a reduction in manufacturing costs'-7, 11. 14-11. It has been stated that although... less thanoncea day. Funhermore, confusionsG~ existed with respect to temperature (i e glue line or surface) and nressure laress or air line) s~ecifications and a wide ranee of temperatures &ere deingempibYedfor thesakeiype of adhesive. ~ ~ ~ a r e n...

  1. The surgery of peripheral nerves (including tumors)

    DEFF Research Database (Denmark)

    Fugleholm, Kåre

    2013-01-01

    Surgical pathology of the peripheral nervous system includes traumatic injury, entrapment syndromes, and tumors. The recent significant advances in the understanding of the pathophysiology and cellular biology of peripheral nerve degeneration and regeneration has yet to be translated into improved...... surgical techniques and better outcome after peripheral nerve injury. Decision making in peripheral nerve surgery continues to be a complex challenge, where the mechanism of injury, repeated clinical evaluation, neuroradiological and neurophysiological examination, and detailed knowledge of the peripheral...... nervous system response to injury are prerequisite to obtain the best possible outcome. Surgery continues to be the primary treatment modality for peripheral nerve tumors and advances in adjuvant oncological treatment has improved outcome after malignant peripheral nerve tumors. The present chapter...

  2. Characterization of deep wet etching of fused silica glass for single cell and optical sensor deposition

    International Nuclear Information System (INIS)

    Zhu, Haixin; Holl, Mark; Ray, Tathagata; Bhushan, Shivani; Meldrum, Deirdre R

    2009-01-01

    The development of a high-throughput single-cell metabolic rate monitoring system relies on the use of transparent substrate material for a single cell-trapping platform. The high optical transparency, high chemical resistance, improved surface quality and compatibility with the silicon micromachining process of fused silica make it very attractive and desirable for this application. In this paper, we report the results from the development and characterization of a hydrofluoric acid (HF) based deep wet-etch process on fused silica. The pin holes and notching defects of various single-coated masking layers during the etching are characterized and the most suitable masking materials are identified for different etch depths. The dependence of the average etch rate and surface roughness on the etch depth, impurity concentration and HF composition are also examined. The resulting undercut from the deep HF etch using various masking materials is also investigated. The developed and characterized process techniques have been successfully implemented in the fabrication of micro-well arrays for single cell trapping and sensor deposition. Up to 60 µm deep micro-wells have been etched in a fused silica substrate with over 90% process yield and repeatability. To our knowledge, such etch depth has never been achieved in a fused silica substrate by using a non-diluted HF etchant and a single-coated masking layer at room temperature

  3. Post-processing of fused silica and its effects on damage resistance to nanosecond pulsed UV lasers.

    Science.gov (United States)

    Ye, Hui; Li, Yaguo; Zhang, Qinghua; Wang, Wei; Yuan, Zhigang; Wang, Jian; Xu, Qiao

    2016-04-10

    HF-based (hydrofluoric acid) chemical etching has been a widely accepted technique to improve the laser damage performance of fused silica optics and ensure high-power UV laser systems at designed fluence. Etching processes such as acid concentration, composition, material removal amount, and etching state (etching with additional acoustic power or not) may have a great impact on the laser-induced damage threshold (LIDT) of treated sample surfaces. In order to find out the effects of these factors, we utilized the Taguchi method to determine the etching conditions that are helpful in raising the LIDT. Our results show that the most influential factors are concentration of etchants and the material etched away from the viewpoint of damage performance of fused silica optics. In addition, the additional acoustic power (∼0.6  W·cm-2) may not benefit the etching rate and damage performance of fused silica. Moreover, the post-cleaning procedure of etched samples is also important in damage performances of fused silica optics. Different post-cleaning procedures were, thus, experiments on samples treated under the same etching conditions. It is found that the "spraying + rinsing + spraying" cleaning process is favorable to the removal of etching-induced deposits. Residuals on the etched surface are harmful to surface roughness and optical transmission as well as laser damage performance.

  4. Peripheral Circulatory Features during High-Frequency Jet Ventilation

    Directory of Open Access Journals (Sweden)

    M. B. Kontorovich

    2010-01-01

    Full Text Available The paper gives the results of a study of peripheral circulatory features during high-frequency jet ventilation (HFJV. The main specific features of peripheral circulation and oxygen transport during HFJV are formulated on the basis of a study of cardiac output (impedance cardiography, peripheral vascular resistance, peripheral vascular blood filling (photoplethysmogram analysis, adaptive peripheral blood flow reactions (spectral analysis of peripheral vascular pulsation. HFJV gives rise to the peculiar pattern of peripheral hemodynamics and tissue gas exchange, which is characterized by higher oxygen uptake without a decrease in mixed venous blood saturation, with normal extraction coefficient and preserved low peripheral vascular resistance. During HFJV, unlike traditional ventilation, the main peripheral hemodynamic feature is the increased capillary bed blood volume caused by the blood flow involvement of reserve capillaries under control of volume (parasympathetic regulation of adaptive peripheral hemodynamic reactions. Key words: high-frequency jet ventilation, oxygen transport, peripheral hemodynamics.

  5. Controllable damping of high-Q violin modes in fused silica suspension fibers

    Energy Technology Data Exchange (ETDEWEB)

    Dmitriev, A V; Mescheriakov, S D; Mitrofanov, V P [Faculty of Physics, Moscow State University, Moscow 119991 (Russian Federation); Tokmakov, K V, E-mail: dmitriev@hbar.phys.msu.r, E-mail: mitr@hbar.phys.msu.r [Present address: Department of Physics, SUPA, University of Strathclyde, Glasgow G4 0NG (United Kingdom)

    2010-01-21

    Fused silica fiber suspension of the test masses will be used in the interferometric gravitational wave detectors of the next generation. This allows a significant reduction of losses in the suspension and thermal noise associated with the suspension. Unfortunately, unwanted violin modes may be accidentally excited in the suspension fibers. The Q-factor of the violin modes also exceeds 10{sup 8}. They have a ring-down time that is too long and may complicate the stable control of the interferometer. Results of the investigation of a violin mode active damping system are described. An original sensor and actuator were especially developed to realize the effective coupling of a thin, optically transparent, non-conducting fused silica fiber with an electric circuit. The damping system allowed the changing of the violin mode's damping rate over a wide range.

  6. Controllable damping of high-Q violin modes in fused silica suspension fibers

    International Nuclear Information System (INIS)

    Dmitriev, A V; Mescheriakov, S D; Mitrofanov, V P; Tokmakov, K V

    2010-01-01

    Fused silica fiber suspension of the test masses will be used in the interferometric gravitational wave detectors of the next generation. This allows a significant reduction of losses in the suspension and thermal noise associated with the suspension. Unfortunately, unwanted violin modes may be accidentally excited in the suspension fibers. The Q-factor of the violin modes also exceeds 10 8 . They have a ring-down time that is too long and may complicate the stable control of the interferometer. Results of the investigation of a violin mode active damping system are described. An original sensor and actuator were especially developed to realize the effective coupling of a thin, optically transparent, non-conducting fused silica fiber with an electric circuit. The damping system allowed the changing of the violin mode's damping rate over a wide range.

  7. Smoothing of Fused Spectral Consistent Satellite Images with TV-based Edge Detection

    DEFF Research Database (Denmark)

    Sveinsson, Johannes; Aanæs, Henrik; Benediktsson, Jon Atli

    2007-01-01

    based on satellite data. Additionally, most conventional methods are loosely connected to the image forming physics of the satellite image, giving these methods an ad hoc feel. Vesteinsson et al. [1] proposed a method of fusion of satellite images that is based on the properties of imaging physics...... in a statistically meaningful way and was called spectral consistent panshapening (SCP). In this paper we improve this framework for satellite image fusion by introducing a better image prior, via data-dependent image smoothing. The dependency is obtained via total variation edge detection method.......Several widely used methods have been proposed for fusing high resolution panchromatic data and lower resolution multi-channel data. However, many of these methods fail to maintain the spectral consistency of the fused high resolution image, which is of high importance to many of the applications...

  8. Optical and electrical properties of boron doped diamond thin conductive films deposited on fused silica glass substrates

    Energy Technology Data Exchange (ETDEWEB)

    Ficek, M.; Sobaszek, M.; Gnyba, M. [Department of Metrology and Optoelectronics, Gdansk University of Technology, 11/12G. Narutowicza St., 80-233 Gdansk (Poland); Ryl, J. [Department of Electrochemistry, Corrosion and Material Engineering, Gdansk University of Technology, 11/12 Narutowicza St., 80-233 Gdansk (Poland); Gołuński, Ł. [Department of Metrology and Optoelectronics, Gdansk University of Technology, 11/12G. Narutowicza St., 80-233 Gdansk (Poland); Smietana, M.; Jasiński, J. [Institute of Microelectronics and Optoelectronics, Warsaw University of Technology, 75 Koszykowa St., 00-662 Warsaw (Poland); Caban, P. [Institute of Electronic Materials Technology, 133 Wolczynska St., 01-919 Warsaw (Poland); Bogdanowicz, R., E-mail: rbogdan@eti.pg.gda.pl [Department of Metrology and Optoelectronics, Gdansk University of Technology, 11/12G. Narutowicza St., 80-233 Gdansk (Poland); Materials and Process Simulation Center, California Institute of Technology, Pasadena, CA 91125 (United States)

    2016-11-30

    Highlights: • Growth of 60% of transmittance diamond films with resistivity as low as 48 Ω cm. • Two step seeding process of fused silica: plasma hydrogenation and wet seeding. • Nanodiamond seeding density of 2 × 10{sup 10} cm{sup −2} at fused silica substrates. • High refractive index (2.4 @550 nm) was achieved for BDD films deposited at 500 °C. - Abstract: This paper presents boron-doped diamond (BDD) film as a conductive coating for optical and electronic purposes. Seeding and growth processes of thin diamond films on fused silica have been investigated. Growth processes of thin diamond films on fused silica were investigated at various boron doping level and methane admixture. Two step pre-treatment procedure of fused silica substrate was applied to achieve high seeding density. First, the substrates undergo the hydrogen plasma treatment then spin-coating seeding using a dispersion consisting of detonation nanodiamond in dimethyl sulfoxide with polyvinyl alcohol was applied. Such an approach results in seeding density of 2 × 10{sup 10} cm{sup −2}. The scanning electron microscopy images showed homogenous, continuous and polycrystalline surface morphology with minimal grain size of 200 nm for highly boron doped films. The sp{sup 3}/sp{sup 2} ratio was calculated using Raman spectra deconvolution method. A high refractive index (range of 2.0–2.4 @550 nm) was achieved for BDD films deposited at 500 °C. The values of extinction coefficient were below 0.1 at λ = 550 nm, indicating low absorption of the film. The fabricated BDD thin films displayed resistivity below 48 Ohm cm and transmittance over 60% in the visible wavelength range.

  9. Stimulated resonant scattering at stressed fused silica surface

    International Nuclear Information System (INIS)

    Bouchut, Philippe; Reymermier, Maryse

    2015-01-01

    The radiative emission in CO 2 laser heated stressed fused silica is radically modified when gold microspheres are on the surface. At high heating rates, the emission dynamics changes from thermoluminescence to stimulated resonant scattering with an emission rate that is increased tenfold and the near infrared (NIR) spectrum is red-shifted. We show that the dynamic tensile stress that rises in heated silica is coupled with a fluctuating electromagnetic field that enables electromagnetic friction between moving OH emitters from silica bulk and NIR resonant scatterers at the silica surface. (paper)

  10. Visualization of conserved structures by fusing highly variable datasets.

    Science.gov (United States)

    Silverstein, Jonathan C; Chhadia, Ankur; Dech, Fred

    2002-01-01

    Skill, effort, and time are required to identify and visualize anatomic structures in three-dimensions from radiological data. Fundamentally, automating these processes requires a technique that uses symbolic information not in the dynamic range of the voxel data. We were developing such a technique based on mutual information for automatic multi-modality image fusion (MIAMI Fuse, University of Michigan). This system previously demonstrated facility at fusing one voxel dataset with integrated symbolic structure information to a CT dataset (different scale and resolution) from the same person. The next step of development of our technique was aimed at accommodating the variability of anatomy from patient to patient by using warping to fuse our standard dataset to arbitrary patient CT datasets. A standard symbolic information dataset was created from the full color Visible Human Female by segmenting the liver parenchyma, portal veins, and hepatic veins and overwriting each set of voxels with a fixed color. Two arbitrarily selected patient CT scans of the abdomen were used for reference datasets. We used the warping functions in MIAMI Fuse to align the standard structure data to each patient scan. The key to successful fusion was the focused use of multiple warping control points that place themselves around the structure of interest automatically. The user assigns only a few initial control points to align the scans. Fusion 1 and 2 transformed the atlas with 27 points around the liver to CT1 and CT2 respectively. Fusion 3 transformed the atlas with 45 control points around the liver to CT1 and Fusion 4 transformed the atlas with 5 control points around the portal vein. The CT dataset is augmented with the transformed standard structure dataset, such that the warped structure masks are visualized in combination with the original patient dataset. This combined volume visualization is then rendered interactively in stereo on the ImmersaDesk in an immersive Virtual

  11. Peripherally applied opioids for postoperative pain

    DEFF Research Database (Denmark)

    Nielsen, B N; Henneberg, S W; Schmiegelow, K

    2015-01-01

    BACKGROUND: Opioids applied peripherally at the site of surgery may produce postoperative analgesia with few side effects. We performed this systematic review to evaluate the analgesic effect of peripherally applied opioids for acute postoperative pain. METHODS: We searched PubMed (1966 to June...... 2013), Embase (1980 to June 2013), and the Cochrane Central Register of Controlled Trials (The Cochrane Library 2013, Issue 6). Randomized controlled trials investigating the postoperative analgesic effect of peripherally applied opioids vs. systemic opioids or placebo, measured by pain intensity...... difference -5 mm, 95% CI: -7 to -3) for peripherally applied opioids vs. placebo and statistically significant increased time to first analgesic (mean difference 153 min, 95% CI: 41-265). When preoperative inflammation was reported (five studies), peripherally applied opioids significantly improved...

  12. Ureteral Involvement Within an Incarcerated Inguinal Hernia in a Patient With Crossed-fused Renal Ectopia

    Directory of Open Access Journals (Sweden)

    Udit Singhal

    2016-07-01

    Full Text Available Crossed-fused renal ectopy is an uncommon abnormality of the genitourinary tract that results from errors during embryological development. Ureteral herniation represents another rare anatomic event and can often occur from spontaneous, postoperative, and congenital causes (Allam, Johnson, Grewal & Johnson 2015; Pollack, Popky & Blumberg 1975. Here, we discuss the complex clinical course of a patient with crossed-fused renal ectopia who presents with symptoms due to ureteroinguinal herniation and provide a brief overview of the literature. We highlight the clinical considerations in the management of this patient and provide a potential anatomical and embryological explanation for his presentation.

  13. Fusing Recommendations for Social Bookmarking Websites

    DEFF Research Database (Denmark)

    Bogers, Toine; van den Bosch, Antal

    2011-01-01

    Social bookmarking websites are rapidly growing in popularity. Recommender systems, a promising remedy to the information overload accompanying the explosive growth in content, are designed to identify which unseen content might be of interest to a particular user, based on his or her past...... that use tag overlap and metadata provide better results for social bookmarking data sets than the transaction patterns that are used traditionally in recommender systems research. In addition, we investigate how to fuse different recommendation approaches to further improve recommendation accuracy. We...... preferences. Most previous work in recommendation for social bookmarking suffers from a lack of comparisons between the different available approaches. In this article, we address this issue by comparing and evaluating eight recommendation approaches on four data sets from two domains. We find that approaches...

  14. Microwave interrogated large core fused silica fiber Michelson interferometer for strain sensing.

    Science.gov (United States)

    Hua, Liwei; Song, Yang; Huang, Jie; Lan, Xinwei; Li, Yanjun; Xiao, Hai

    2015-08-20

    A Michelson-type large core optical fiber sensor has been developed, which is designed based on the optical carrier-based microwave interferometry technique, and fabricated by using two pieces of 200-μm diameter fused silica core fiber as two arms of the Michelson interferometer. The interference fringe pattern caused by the optical path difference of the two arms is interrogated in the microwave domain, where the fringe visibility of 40 dB has easily been obtained. The strain sensing at both room temperature and high temperatures has been demonstrated by using such a sensor. Experimental results show that this sensor has a linear response to the applied strain, and also has relatively low temperature-strain cross talk. The dopant-free quality of the fused silica fiber provides high possibility for the sensor to have promising strain sensing performance in a high temperature environment.

  15. Morphology Analysis and Process Research on Novel Metal Fused-coating Additive Manufacturing

    Science.gov (United States)

    Wang, Xin; Wei, Zheng ying; Du, Jun; Ren, Chuan qi; Zhang, Shan; Zhang, Zhitong; Bai, Hao

    2017-12-01

    Existing metal additive manufacturing equipment has high capital costs and slow throughput printing. In this paper, a new metal fused-coating additive manufacturing (MFCAM) was proposed. Experiments of single-track formation were conducted using MFCAM to validate the feasibility. The low melting alloy was selected as the forming material. Then, the effect of process parameters such as the flow rate, deposition velocity and initial distance on the forming morphology. There is a strong coupling effect between the single track forming morphology. Through the analysis of influencing factors to improve the forming quality of specimens. The experimental results show that the twice as forming efficiency as the metal droplet deposition. Additionally, the forming morphology and quality were analyzed by confocal laser scanning microscope and X-ray. The results show that the metal fused-coating process can achieve good surface morphology and without internal tissue defect.

  16. Molecular design of high performance fused heteroacene radical cations: A DFT study

    International Nuclear Information System (INIS)

    Kawabata, Hiroshi; Ohmori, Shigekazu; Matsushige, Kazumi; Tachikawa, Hiroto

    2008-01-01

    Hybrid density functional theory (DFT) calculations have been carried out for neutral and radical cation of fused furan oligomer, denoted by F(n) where n means number of furan rings in the oligomer, to elucidate the electronic structures at ground and low-lying excited states. A polymer of fused furan was also investigated using one-dimensional periodic boundary condition (PBC) for comparison. It was found that the reorganization energy of radical cation of F(n) from vertical hole trapping point to its relaxed structure is significantly small. Also, the reorganization energy decreased gradually with increasing n, indicating that F(n) has an effective hole transport property. It was found that the cation radical of F(n) has a low energy band at near IR region, which is strongly correlated to hole conductivity. The relation between the electronic states and hole conductivity was discussed on the basis of theoretical calculations

  17. Burn-related peripheral neuropathy: A systematic review.

    Science.gov (United States)

    Tu, Yiji; Lineaweaver, William C; Zheng, Xianyou; Chen, Zenggan; Mullins, Fred; Zhang, Feng

    2017-06-01

    Peripheral neuropathy is the most frequent disabling neuromuscular complication of burns. However, the insidious and progressive onset of burn neuropathy makes it often undiagnosed or overlooked. In our study, we reviewed the current studies on the burn-related peripheral neuropathy to summarize the morbidity, mechanism, detecting method and management of peripheral neuropathy in burn patients. Of the 1533 burn patients included in our study, 98 cases (6.39%) were presented with peripheral neuropathy. Thermal and electrical burns were the most common etiologies. Surgical procedures, especially nerve decompression, showed good effect on functional recovery of both acute and delayed peripheral neuropathy in burn patients. It is noteworthy that, for early detection and prevention of peripheral neuropathy, electrodiagnostic examinations should be performed on burn patients independent of symptoms. Still, the underlying mechanisms of burn-related peripheral neuropathy remain to be clarified. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  18. Conjugate acene fused buckybowls: evaluating their suitability for p-type, ambipolar and n-type air stable organic semiconductors.

    Science.gov (United States)

    Purushotham, Uppula; Sastry, G Narahari

    2013-04-14

    Elaborate and exhaustive first principles calculations were carried out to screen the novel properties of a series of acene fused buckybowls. The acene fused compounds exhibit hole transport property due to their higher electron injection and lower hole transport barrier relative to the work function potential of Au electrodes. The higher HOMO and lower LUMO energy levels suggest lower hole and electron injection barriers of F and CN substituted and boron doped bowls which indicates ambipolar property of these bowls. The dicyano substituted pentacene fused bowls show only electron transport property with lower LUMO (-4.26 eV to -4.27 eV) and higher HOMO (-5.56 eV to -5.90 eV) energy levels. High electron affinity (>2.80 eV) and low LUMO energy (semiconductors.

  19. Automatic registration of fused lidar/digital imagery (texel images) for three-dimensional image creation

    Science.gov (United States)

    Budge, Scott E.; Badamikar, Neeraj S.; Xie, Xuan

    2015-03-01

    Several photogrammetry-based methods have been proposed that the derive three-dimensional (3-D) information from digital images from different perspectives, and lidar-based methods have been proposed that merge lidar point clouds and texture the merged point clouds with digital imagery. Image registration alone has difficulty with smooth regions with low contrast, whereas point cloud merging alone has difficulty with outliers and a lack of proper convergence in the merging process. This paper presents a method to create 3-D images that uses the unique properties of texel images (pixel-fused lidar and digital imagery) to improve the quality and robustness of fused 3-D images. The proposed method uses both image processing and point-cloud merging to combine texel images in an iterative technique. Since the digital image pixels and the lidar 3-D points are fused at the sensor level, more accurate 3-D images are generated because registration of image data automatically improves the merging of the point clouds, and vice versa. Examples illustrate the value of this method over other methods. The proposed method also includes modifications for the situation where an estimate of position and attitude of the sensor is known, when obtained from low-cost global positioning systems and inertial measurement units sensors.

  20. Surgical and orthodontic management of fused maxillary central and lateral incisors in early mixed dentition stage.

    Science.gov (United States)

    Ramamurthy, Suresh; Satish, Ramaswamy; Priya, Kalidass

    2014-01-01

    Fusion is one of the developmental dental anomalies in which two adjacent teeth are joined at the crown level forming a single tooth with an enlarged crown. Fusion causes some clinical problems such as unaesthetic appearance, pain, caries, and malocclusion. The management of fusion often needs multidisciplinary approach to give best possible esthetic and functional outcome. This paper reports a case of 9-year-old boy with fused maxillary left central and lateral incisors who was treated with 2 × 4 fixed orthodontic appliances after surgical separation of fused teeth.

  1. Surgical and Orthodontic Management of Fused Maxillary Central and Lateral Incisors in Early Mixed Dentition Stage

    Directory of Open Access Journals (Sweden)

    Suresh Ramamurthy

    2014-01-01

    Full Text Available Fusion is one of the developmental dental anomalies in which two adjacent teeth are joined at the crown level forming a single tooth with an enlarged crown. Fusion causes some clinical problems such as unaesthetic appearance, pain, caries, and malocclusion. The management of fusion often needs multidisciplinary approach to give best possible esthetic and functional outcome. This paper reports a case of 9-year-old boy with fused maxillary left central and lateral incisors who was treated with 2×4 fixed orthodontic appliances after surgical separation of fused teeth.

  2. Synthesis of zeolite NaA membrane from fused fly ash extract.

    Science.gov (United States)

    Ameh, Alechine E; Musyoka, Nicholas M; Fatoba, Ojo O; Syrtsova, Daria A; Teplyakov, Vladimir V; Petrik, Leslie F

    2016-01-01

    Zeolite-NaA membranes were synthesized from an extract of fused South African fly ash on a porous titanium support by a secondary growth method. The influence of the synthesis molar regime on the formation of zeolite NaA membrane layer was investigated. Two synthesis mixtures were generated by adding either aluminium hydroxide or sodium aluminate to the fused fly ash extract. The feedstock material and the synthesized membranes were characterized by X-diffraction (XRD), scanning electron microscopy (SEM) and X-ray fluorescence spectroscopy (XRF). It was found by XRD and SEM that the cubic crystals of a typical zeolite NaA with a dense intergrown layer was formed on the porous Ti support. The study shows that the source of Al used had an effect on the membrane integrity as sodium aluminate provided the appropriate amount of Na(+) to form a coherent membrane of zeolite NaA, whereas aluminium hydroxide did not. Morphological, the single hydrothermal stage seeded support formed an interlocked array of zeolite NaA particles with neighbouring crystals. Also, a robust, continuous and well-intergrown zeolite NaA membrane was formed with neighbouring crystals of zeolite fused to each other after the multiple stage synthesis. The synthesized membrane was permeable to He (6.0 × 10(6) L m(-2)h(-1) atm(-1)) and CO2 (5.6 × 10(6) L m(-2)h(-1) atm(-1)), which indicate that the layer of the membrane was firmly attached to the porous Ti support. Membrane selectivity was maintained showing membrane integrity with permselectivity of 1.1, showing that a waste feedstock, fly ash, could be utilized for preparing robust zeolite NaA membranes on Ti support.

  3. Intraoperative Ultrasound for Peripheral Nerve Applications.

    Science.gov (United States)

    Willsey, Matthew; Wilson, Thomas J; Henning, Phillip Troy; Yang, Lynda J-S

    2017-10-01

    Offering real-time, high-resolution images via intraoperative ultrasound is advantageous for a variety of peripheral nerve applications. To highlight the advantages of ultrasound, its extraoperative uses are reviewed. The current intraoperative uses, including nerve localization, real-time evaluation of peripheral nerve tumors, and implantation of leads for peripheral nerve stimulation, are reviewed. Although intraoperative peripheral nerve localization has been performed previously using guide wires and surgical dyes, the authors' approach using ultrasound-guided instrument clamps helps guide surgical dissection to the target nerve, which could lead to more timely operations and shorter incisions. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Information Recovery Algorithm for Ground Objects in Thin Cloud Images by Fusing Guide Filter and Transfer Learning

    Directory of Open Access Journals (Sweden)

    HU Gensheng

    2018-03-01

    Full Text Available Ground object information of remote sensing images covered with thin clouds is obscure. An information recovery algorithm for ground objects in thin cloud images is proposed by fusing guide filter and transfer learning. Firstly, multi-resolution decomposition of thin cloud target images and cloud-free guidance images is performed by using multi-directional nonsubsampled dual-tree complex wavelet transform. Then the decomposed low frequency subbands are processed by using support vector guided filter and transfer learning respectively. The decomposed high frequency subbands are enhanced by using modified Laine enhancement function. The low frequency subbands output by guided filter and those predicted by transfer learning model are fused by the method of selection and weighting based on regional energy. Finally, the enhanced high frequency subbands and the fused low frequency subbands are reconstructed by using inverse multi-directional nonsubsampled dual-tree complex wavelet transform to obtain the ground object information recovery images. Experimental results of Landsat-8 OLI multispectral images show that, support vector guided filter can effectively preserve the detail information of the target images, domain adaptive transfer learning can effectively extend the range of available multi-source and multi-temporal remote sensing images, and good effects for ground object information recover are obtained by fusing guide filter and transfer learning to remove thin cloud on the remote sensing images.

  5. MRI fused with prone FDG PET/CT improves the primary tumour staging of patients with breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Velloso, Maria J.; Ribelles, Maria J.; Rodriguez, Macarena; Sancho, Lidia; Prieto, Elena [Clinica Universidad de Navarra, Department of Nuclear Medicine, Pamplona (Spain); Fernandez-Montero, Alejandro [Clinica Universidad de Navarra, Department of Occupational Medicine, Pamplona (Spain); Santisteban, Marta [Clinica Universidad de Navarra, Department of Oncology, Pamplona (Spain); Rodriguez-Spiteri, Natalia; Martinez-Regueira, Fernando [Clinica Universidad de Navarra, Department of Surgery, Pamplona (Spain); Idoate, Miguel A. [Clinica Universidad de Navarra, Department of Pathology, Pamplona (Spain); Elizalde, Arlette; Pina, Luis J. [Clinica Universidad de Navarra, Department of Radiology, Pamplona (Spain)

    2017-08-15

    Our aim was to evaluate the diagnostic accuracy of magnetic resonance imaging (MRI) fused with prone 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) in primary tumour staging of patients with breast cancer. This retrospective study evaluated 45 women with 49 pathologically proven breast carcinomas. MRI and prone PET-CT scans with time-of-flight and point-spread-function reconstruction were performed with the same dedicated breast coil. The studies were assessed by a radiologist and a nuclear medicine physician, and evaluation of fused images was made by consensus. The final diagnosis was based on pathology (90 lesions) or follow-up ≥ 24 months (17 lesions). The study assessed 72 malignant and 35 benign lesions with a median size of 1.8 cm (range 0.3-8.4 cm): 31 focal, nine multifocal and nine multicentric cases. In lesion-by-lesion analysis, sensitivity, specificity, positive and negative predictive values were 97%, 80%, 91% and 93% for MRI, 96%, 71%, 87%, and 89% for prone PET, and 97%. 94%, 97% and 94% for MRI fused with PET. Areas under the curve (AUC) were 0.953, 0.850, and 0.983, respectively (p < 0.01). MRI fused with FDG-PET is more accurate than FDG-PET in primary tumour staging of breast cancer patients and increases the specificity of MRI. (orig.)

  6. Particle damage sources for fused silica optics and their mitigation on high energy laser systems.

    Science.gov (United States)

    Bude, J; Carr, C W; Miller, P E; Parham, T; Whitman, P; Monticelli, M; Raman, R; Cross, D; Welday, B; Ravizza, F; Suratwala, T; Davis, J; Fischer, M; Hawley, R; Lee, H; Matthews, M; Norton, M; Nostrand, M; VanBlarcom, D; Sommer, S

    2017-05-15

    High energy laser systems are ultimately limited by laser-induced damage to their critical components. This is especially true of damage to critical fused silica optics, which grows rapidly upon exposure to additional laser pulses. Much progress has been made in eliminating damage precursors in as-processed fused silica optics (the advanced mitigation process, AMP3), and very high damage resistance has been demonstrated in laboratory studies. However, the full potential of these improvements has not yet been realized in actual laser systems. In this work, we explore the importance of additional damage sources-in particular, particle contamination-for fused silica optics fielded in a high-performance laser environment, the National Ignition Facility (NIF) laser system. We demonstrate that the most dangerous sources of particle contamination in a system-level environment are laser-driven particle sources. In the specific case of the NIF laser, we have identified the two important particle sources which account for nearly all the damage observed on AMP3 optics during full laser operation and present mitigations for these particle sources. Finally, with the elimination of these laser-driven particle sources, we demonstrate essentially damage free operation of AMP3 fused silica for ten large optics (a total of 12,000 cm 2 of beam area) for shots from 8.6 J/cm 2 to 9.5 J/cm 2 of 351 nm light (3 ns Gaussian pulse shapes). Potentially many other pulsed high energy laser systems have similar particle sources, and given the insight provided by this study, their identification and elimination should be possible. The mitigations demonstrated here are currently being employed for all large UV silica optics on the National Ignition Facility.

  7. Mechanical losses in thin fused silica fibres

    International Nuclear Information System (INIS)

    Bilenko, I A; Braginsky, V B; Lourie, S L

    2004-01-01

    Intracavity topology of the readout system for LIGO III project and table-top QND mechanical measurements under development require the use of small probe masses and suspensions with a very low level of internal losses. A good choice is to use thin fused silica fibres similar to LIGO II mirrors suspensions. Mechanical losses of silica fibres are investigated in this work through the study of quality factor dependence on diameter for pendulum and violin modes of oscillations with diameters ranging from 1.5 to 40 μm. The estimated values of effective mechanical loss angle show noticeably greater growth with lower diameters than might be expected while extrapolating known results of research done for thicker fibres

  8. Mechanical losses in thin fused silica fibres

    Energy Technology Data Exchange (ETDEWEB)

    Bilenko, I A; Braginsky, V B; Lourie, S L [Department of Oscillatory Physics, Physics Faculty, Moscow State University (Russian Federation)

    2004-03-07

    Intracavity topology of the readout system for LIGO III project and table-top QND mechanical measurements under development require the use of small probe masses and suspensions with a very low level of internal losses. A good choice is to use thin fused silica fibres similar to LIGO II mirrors suspensions. Mechanical losses of silica fibres are investigated in this work through the study of quality factor dependence on diameter for pendulum and violin modes of oscillations with diameters ranging from 1.5 to 40 {mu}m. The estimated values of effective mechanical loss angle show noticeably greater growth with lower diameters than might be expected while extrapolating known results of research done for thicker fibres.

  9. The anomalous yield behavior of fused silica glass

    Science.gov (United States)

    Schill, W.; Heyden, S.; Conti, S.; Ortiz, M.

    2018-04-01

    We develop a critical-state model of fused silica plasticity on the basis of data mined from molecular dynamics (MD) calculations. The MD data is suggestive of an irreversible densification transition in volumetric compression resulting in permanent, or plastic, densification upon unloading. The MD data also reveals an evolution towards a critical state of constant volume under pressure-shear deformation. The trend towards constant volume is from above, when the glass is overconsolidated, or from below, when it is underconsolidated. We show that these characteristic behaviors are well-captured by a critical state model of plasticity, where the densification law for glass takes the place of the classical consolidation law of granular media and the locus of constant-volume states defines the critical-state line. A salient feature of the critical-state line of fused silica, as identified from the MD data, that renders its yield behavior anomalous is that it is strongly non-convex, owing to the existence of two well-differentiated phases at low and high pressures. We argue that this strong non-convexity of yield explains the patterning that is observed in molecular dynamics calculations of amorphous solids deforming in shear. We employ an explicit and exact rank-2 envelope construction to upscale the microscopic critical-state model to the macroscale. Remarkably, owing to the equilibrium constraint the resulting effective macroscopic behavior is still characterized by a non-convex critical-state line. Despite this lack of convexity, the effective macroscopic model is stable against microstructure formation and defines well-posed boundary-value problems.

  10. Functional deficits in peripheral nerve mitochondria in rats with paclitaxel- and oxaliplatin-evoked painful peripheral neuropathy

    OpenAIRE

    Zheng, Huaien; Xiao, Wen Hua; Bennett, Gary J.

    2011-01-01

    Cancer chemotherapeutics like paclitaxel and oxaliplatin produce a dose-limiting chronic sensory peripheral neuropathy that is often accompanied by neuropathic pain. The cause of the neuropathy and pain is unknown. In animal models, paclitaxel-evoked and oxaliplatin-evoked painful peripheral neuropathies are accompanied by an increase in the incidence of swollen and vacuolated mitochondria in peripheral nerve axons. It has been proposed that mitochondrial swelling and vacuolation are indicati...

  11. Microwave tomography of extremities: 2. Functional fused imaging of flow reduction and simulated compartment syndrome

    International Nuclear Information System (INIS)

    Semenov, Serguei; Nair, Bindu; Kellam, James; Williams, Thomas; Quinn, Michael; Sizov, Yuri; Nazarov, Alexei; Pavlovsky, Andrey

    2011-01-01

    Medical imaging has recently expanded into the dual- or multi-modality fusion of anatomical and functional imaging modalities. This significantly improves the diagnostic power while simultaneously increasing the cost of already expensive medical devices or investigations and decreasing their mobility. We are introducing a novel imaging concept of four-dimensional (4D) microwave tomographic (MWT) functional imaging: three dimensional (3D) in the spatial domain plus one dimensional (1D) in the time, functional dynamic domain. Instead of a fusion of images obtained by different imaging modalities, 4D MWT fuses absolute anatomical images with dynamic, differential images of the same imaging technology. The approach was successively validated in animal experiments with short-term arterial flow reduction and a simulated compartment syndrome in an initial simplified experimental setting using a dedicated MWT system. The presented fused images are not perfect as MWT is a novel imaging modality at its early stage of the development and ways of reading reconstructed MWT images need to be further studied and understood. However, the reconstructed fused images present clear evidence that microwave tomography is an emerging imaging modality with great potentials for functional imaging.

  12. Mini-review: Far peripheral vision.

    Science.gov (United States)

    Simpson, Michael J

    2017-11-01

    The region of far peripheral vision, beyond 60 degrees of visual angle, is important to the evaluation of peripheral dark shadows (negative dysphotopsia) seen by some intraocular lens (IOL) patients. Theoretical calculations show that the limited diameter of an IOL affects ray paths at large angles, leading to a dimming of the main image for small pupils, and to peripheral illumination by light bypassing the IOL for larger pupils. These effects are rarely bothersome, and cataract surgery is highly successful, but there is a need to improve the characterization of far peripheral vision, for both pseudophakic and phakic eyes. Perimetry is the main quantitative test, but the purpose is to evaluate pathologies rather than characterize vision (and object and image regions are no longer uniquely related in the pseudophakic eye). The maximum visual angle is approximately 105 0 , but there is limited information about variations with age, race, or refractive error (in case there is an unexpected link with the development of myopia), or about how clear cornea, iris location, and the limiting retina are related. Also, the detection of peripheral motion is widely recognized to be important, yet rarely evaluated. Overall, people rarely complain specifically about this visual region, but with "normal" vision including an IOL for >5% of people, and increasing interest in virtual reality and augmented reality, there are new reasons to characterize peripheral vision more completely. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. The chemistry of furazans fused to six- and seven-membered heterocycles with one heteroatom

    International Nuclear Information System (INIS)

    Sheremetev, Aleksei B

    1999-01-01

    The data on the synthesis and properties of furazan derivatives fused with pyridine, pyran, thiopyran, azepine and thiepine rings are surveyed and described systematically. The bibliography includes 85 references.

  14. Fused 1,2,3-Dithiazoles: Convenient Synthesis, Structural Characterization, and Electrochemical Properties

    Directory of Open Access Journals (Sweden)

    Lidia S. Konstantinova

    2016-05-01

    Full Text Available A new general protocol for synthesis of fused 1,2,3-dithiazoles by the reaction of cyclic oximes with S2Cl2 and pyridine in acetonitrile has been developed. The target 1,2,3-dithiazoles fused with various carbocycles, such as indene, naphthalenone, cyclohexadienone, cyclopentadiene, and benzoannulene, were selectively obtained in low to high yields. In most cases, the hetero ring-closure was accompanied by chlorination of the carbocyclic moieties. With naphthalenone derivatives, a novel dithiazole rearrangement (15→13 featuring unexpected movement of the dithiazole ring from α- to β-position, with respect to keto group, was discovered. Molecular structure of 4-chloro-5H-naphtho[1,2-d][1,2,3]dithiazol-5-one 13 was confirmed by single-crystal X-ray diffraction. Electrochemical properties of 13 were studied by cyclic voltammetry and a complex behavior was observed, most likely including hydrodechlorination at a low potential.

  15. Collaborative Filtering Fusing Label Features Based on SDAE

    DEFF Research Database (Denmark)

    Huo, Huan; Liu, Xiufeng; Zheng, Deyuan

    2017-01-01

    problem, auxiliary information such as labels are utilized. Another approach of recommendation system is content-based model which can’t be directly integrated with CF-based model due to its inherent characteristics. Considering that deep learning algorithms are capable of extracting deep latent features......, this paper applies Stack Denoising Auto Encoder (SDAE) to content-based model and proposes LCF(Deep Learning for Collaborative Filtering) algorithm by combing CF-based model which fuses label features. Experiments on real-world data sets show that DLCF can largely overcome the sparsity problem...... and significantly improves the state of art approaches....

  16. Design of a Rad-Hard eFuse Trimming Circuit for Bandgap Voltage Reference for LHC Experiments Upgrades

    CERN Document Server

    Besirli, Mustafa; Koukab, Adil; Michelis, Stefano

    A precise and stable reference voltage is required to generate a stable output voltage in DC/DC converters. This reference voltage must be independent of temperature, power supply, radiation, intrinsic technology mismatch and process variation. This master's thesis reports the development of a rad-hard bandgap voltage reference with electrical fuse (eFuse) based analog calibration circuit in a commercial 130nm technology. According to the test results, the maximum error in the bandgap voltage (300mV in this application) was reduced from ±30mV to less than ±0.6mV thanks to the eFuse trimming. A temperature, power supply, radiation, mismatch and process-independent reference voltage was generated to provide reference voltage to first (bPOL12V) and second (bPOL2V5) stage DC/DC converters. This circuit will be integrated in bPOL12V and bPOL2V5 converters for high-luminosity LHC upgrades.

  17. Long term clinical outcome of peripheral nerve stimulation in patients with chronic peripheral neuropathic pain

    DEFF Research Database (Denmark)

    Calenbergh, F. Van; Gybels, J.; Laere, K. Van

    2009-01-01

    BACKGROUND: Chronic neuropathic pain after injury to a peripheral nerve is known to be resistant to treatment. Peripheral nerve stimulation is one of the possible treatment options, which is, however, not performed frequently. In recent years we have witnessed a renewed interest for PNS. The aim...... of the present study was to evaluate the long-term clinical efficacy of PNS in a group of patients with peripheral neuropathic pain treated with PNS since the 1980s. METHODS: Of an original series of 11 patients, 5 patients could be invited for clinical examination, detailed assessment of clinical pain and QST...... functioning) also showed positive effects. Quantitative Sensory Testing results did not show significant differences in cold pain and heat pain thresholds between the "ON" and "OFF" conditions. CONCLUSION: In selected patients with peripheral neuropathic pain PNS remains effective even after more than 20...

  18. Enzymatic Baeyer-Villiger Oxidation of Benzo-Fused Ketones : Formation of Regiocomplementary Lactones

    NARCIS (Netherlands)

    Rioz-Martinez, Ana; de Gonzalo, Gonzalo; Pazmino, Daniel E. Torres; Fraaije, Marco W.; Gotor, Vicente

    Baeyer-Villiger monooxygenases (BVMOs) are enzymes that are known to catalyse the Baeyer-Villiger oxidation of ketones in aqueous media using O(2) as oxidant. Herein, we describe the oxidation of a set of diverse benzo-fused ketones by three different BVMOs in both aqueous and non-conventional

  19. Surface roughening of ground fused silica processed by atmospheric inductively coupled plasma

    International Nuclear Information System (INIS)

    Xin, Qiang; Li, Na; Wang, Jun; Wang, Bo; Li, Guo; Ding, Fei; Jin, Huiliang

    2015-01-01

    Highlights: • The morphology evolution of ground fused silica, processed by atmospheric plasma, was investigated experimentally. • The roughness development results from opening and coalescing of the plasma-etched cracks. • The shapes of grain-like etched pits are the results of the adjacent cracks coalescing with one another. • The descent of the pits density is due to some smaller etched pits that are swallowed up by larger pits. • Leading role in surface smoothing is laterally etching away the side walls of the intersecting pits. - Abstract: Subsurface damage (SSD) is a defect that is inevitably induced during mechanical processes, such as grinding and polishing. This defect dramatically reduces the mechanical strength and the laser damage thresholds of optical elements. Compared with traditional mechanical machining, atmospheric pressure plasma processing (APPP) is a relatively novel technology that induces almost no SSD during the processing of silica-based optical materials. In this paper, a form of APPP, inductively coupled plasma (ICP), is used to process fused silica substrates with fluorocarbon precursor under atmospheric pressure. The surface morphology evolution of ICP-processed substrates was observed and characterized by confocal laser scanning microscope (CLSM), field emission scanning electron microscope (SEM), and atomic force microscopy (AFM). The results show that the roughness evolves with the etching depth, and the roughness evolution is a single-peaked curve. This curve results from the opening and the coalescing of surface cracks and fractures. The coalescence procedure of these microstructures was simulated with two common etched pits on a polished fused silica surface. Understanding the roughness evolution of plasma-processed surface might be helpful in optimizing the optical fabrication chain that contains APPP

  20. Surface roughening of ground fused silica processed by atmospheric inductively coupled plasma

    Energy Technology Data Exchange (ETDEWEB)

    Xin, Qiang; Li, Na; Wang, Jun; Wang, Bo, E-mail: bradywang@hit.edu.cn; Li, Guo; Ding, Fei; Jin, Huiliang

    2015-06-30

    Highlights: • The morphology evolution of ground fused silica, processed by atmospheric plasma, was investigated experimentally. • The roughness development results from opening and coalescing of the plasma-etched cracks. • The shapes of grain-like etched pits are the results of the adjacent cracks coalescing with one another. • The descent of the pits density is due to some smaller etched pits that are swallowed up by larger pits. • Leading role in surface smoothing is laterally etching away the side walls of the intersecting pits. - Abstract: Subsurface damage (SSD) is a defect that is inevitably induced during mechanical processes, such as grinding and polishing. This defect dramatically reduces the mechanical strength and the laser damage thresholds of optical elements. Compared with traditional mechanical machining, atmospheric pressure plasma processing (APPP) is a relatively novel technology that induces almost no SSD during the processing of silica-based optical materials. In this paper, a form of APPP, inductively coupled plasma (ICP), is used to process fused silica substrates with fluorocarbon precursor under atmospheric pressure. The surface morphology evolution of ICP-processed substrates was observed and characterized by confocal laser scanning microscope (CLSM), field emission scanning electron microscope (SEM), and atomic force microscopy (AFM). The results show that the roughness evolves with the etching depth, and the roughness evolution is a single-peaked curve. This curve results from the opening and the coalescing of surface cracks and fractures. The coalescence procedure of these microstructures was simulated with two common etched pits on a polished fused silica surface. Understanding the roughness evolution of plasma-processed surface might be helpful in optimizing the optical fabrication chain that contains APPP.

  1. 2012 and 2013 Air Quality Fused Surface for the Conterminous U.S. Map Service

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web service contains a polygon layer that depicts fused air quality predictions for 2012, 2013, and 2014 for census tracts in the conterminous United States....

  2. Supercritical water-treated fused silica capillaries in analytical separations: Status review

    Czech Academy of Sciences Publication Activity Database

    Karásek, Pavel; Horká, Marie; Šlais, Karel; Planeta, Josef; Roth, Michal

    2018-01-01

    Roč. 1539, MAR (2018), s. 1-11 ISSN 0021-9673 R&D Projects: GA MV VI20172020069; GA ČR(CZ) GA16-03749S; GA MZd(CZ) NV16-29916A Institutional support: RVO:68081715 Keywords : supercritical water * fused silica capillary * surface treatment Subject RIV: CB - Analytical Chemistry, Separation OBOR OECD: Analytical chemistry Impact factor: 3.981, year: 2016

  3. Thiophene-fused tetracene diimide with low band gap and ambipolar behavior

    KAUST Repository

    Ye, Qun; Chang, Jingjing; Huang, Kuo-Wei; Chi, Chunyan

    2011-01-01

    The first tetracene diimide derivative fused with four thiophene rings, TT-TDI, was synthesized by an FeCl3 mediated oxidative cyclodehydrogenation reaction. TT-TDI exhibited a low band gap of 1.52 eV and amphoteric redox behavior. TT-TDI also showed a liquid crystalline property and ambipolar charge transport in thin film field-effect transistors. © 2011 American Chemical Society.

  4. Thiophene-fused tetracene diimide with low band gap and ambipolar behavior

    KAUST Repository

    Ye, Qun

    2011-11-18

    The first tetracene diimide derivative fused with four thiophene rings, TT-TDI, was synthesized by an FeCl3 mediated oxidative cyclodehydrogenation reaction. TT-TDI exhibited a low band gap of 1.52 eV and amphoteric redox behavior. TT-TDI also showed a liquid crystalline property and ambipolar charge transport in thin film field-effect transistors. © 2011 American Chemical Society.

  5. Normal and sonographic anatomy of selected peripheral nerves. Part III: Peripheral nerves of the lower limb.

    Science.gov (United States)

    Kowalska, Berta; Sudoł-Szopińska, Iwona

    2012-06-01

    The ultrasonographic examination is currently increasingly used in imaging peripheral nerves, serving to supplement the physical examination, electromyography and magnetic resonance imaging. As in the case of other USG imaging studies, the examination of peripheral nerves is non-invasive and well-tolerated by patients. The typical ultrasonographic picture of peripheral nerves as well as the examination technique have been discussed in part I of this article series, following the example of the median nerve. Part II of the series presented the normal anatomy and the technique for examining the peripheral nerves of the upper limb. This part of the article series focuses on the anatomy and technique for examining twelve normal peripheral nerves of the lower extremity: the iliohypogastric and ilioinguinal nerves, the lateral cutaneous nerve of the thigh, the pudendal, sciatic, tibial, sural, medial plantar, lateral plantar, common peroneal, deep peroneal and superficial peroneal nerves. It includes diagrams showing the proper positioning of the sonographic probe, plus USG images of the successively discussed nerves and their surrounding structures. The ultrasonographic appearance of the peripheral nerves in the lower limb is identical to the nerves in the upper limb. However, when imaging the lower extremity, convex probes are more often utilized, to capture deeply-seated nerves. The examination technique, similarly to that used in visualizing the nerves of upper extremity, consists of locating the nerve at a characteristic anatomic reference point and tracking it using the "elevator technique". All 3 parts of the article series should serve as an introduction to a discussion of peripheral nerve pathologies, which will be presented in subsequent issues of the "Journal of Ultrasonography".

  6. Experimental Setup for Ultrasonic-Assisted Desktop Fused Deposition Modeling System

    OpenAIRE

    Maidin, S.; Muhamad, M. K.; Pei, Eujin

    2014-01-01

    Fused deposition modeling (FDM) is an additive manufacturing (AM) process that has been used in various manufacturing fields. However, the drawback of FDM is poor surface finish of part produced, leading to surface roughness and requires hand finishing. In this study, ultrasonic technology will be integrated into a desktop FDM system. Ultrasound has been applied in various conventional machining process and shows good machined surface finish. However, very little research regarding the applic...

  7. A new systems engineering approach to streamlined science and mission operations for the Far Ultraviolet Spectroscopic Explorer (FUSE)

    Science.gov (United States)

    Butler, Madeline J.; Sonneborn, George; Perkins, Dorothy C.

    1994-01-01

    The Mission Operations and Data Systems Directorate (MO&DSD, Code 500), the Space Sciences Directorate (Code 600), and the Flight Projects Directorate (Code 400) have developed a new approach to combine the science and mission operations for the FUSE mission. FUSE, the last of the Delta-class Explorer missions, will obtain high resolution far ultraviolet spectra (910 - 1220 A) of stellar and extragalactic sources to study the evolution of galaxies and conditions in the early universe. FUSE will be launched in 2000 into a 24-hour highly eccentric orbit. Science operations will be conducted in real time for 16-18 hours per day, in a manner similar to the operations performed today for the International Ultraviolet Explorer. In a radical departure from previous missions, the operations concept combines spacecraft and science operations and data processing functions in a single facility to be housed in the Laboratory for Astronomy and Solar Physics (Code 680). A small missions operations team will provide the spacecraft control, telescope operations and data handling functions in a facility designated as the Science and Mission Operations Center (SMOC). This approach will utilize the Transportable Payload Operations Control Center (TPOCC) architecture for both spacecraft and instrument commanding. Other concepts of integrated operations being developed by the Code 500 Renaissance Project will also be employed for the FUSE SMOC. The primary objective of this approach is to reduce development and mission operations costs. The operations concept, integration of mission and science operations, and extensive use of existing hardware and software tools will decrease both development and operations costs extensively. This paper describes the FUSE operations concept, discusses the systems engineering approach used for its development, and the software, hardware and management tools that will make its implementation feasible.

  8. Treatment of painful diabetic peripheral neuropathy.

    Science.gov (United States)

    Rosenberg, Casandra J; Watson, James C

    2015-02-01

    Painful diabetic peripheral neuropathy impairs quality of life and can be difficult to treat. To discuss current treatment recommendations for painful diabetic peripheral neuropathy. Literature review. Systematic review of the literature discussing treatment of painful diabetic peripheral neuropathy. Existing treatment guidelines were studied and compared. Painful diabetic peripheral neuropathy occurs in about one in six people with diabetes. This condition impairs quality of life and increases healthcare costs. Treatment recommendations exist, but individual patient therapy can require a trial-and-error approach. Many treatment options have adjuvant benefits or side effects which should be considered prior to initiating therapy. Often, a combination of treatment modalities with various mechanisms of action is required for adequate pain control. Adequate medication titration and a reasonable trial period should be allowed. The treatment of painful diabetic peripheral neuropathy can be challenging, but effective management can improve patient's quality of life. Painful diabetic peripheral neuropathy impairs quality of life and can be difficult to treat. Many treatment options have adjuvant benefits or side effects which should be considered prior to initiating therapy. Often, a combination of treatment modalities with various mechanisms of action is required for adequate pain control. © The International Society for Prosthetics and Orthotics 2014.

  9. Evaluation of pulmonary emphysema by the fused image of CT image and ventilation SPECT image

    International Nuclear Information System (INIS)

    Okuda, Ituko; Maruno, Hiromasa; Mori, Kazuaki; Kohno, Tadashi; Kokubo, Takashi

    2007-01-01

    We evaluated pulmonary emphysema using a diagnostic device that could obtain a CT image, a ventilation single photon emission computed tomography (SPECT) image and a lung perfusion SPECT image in one examination. The fused image made from the CT image and SPECT image had very little position gap between images, and the precision was high. From the fused image, we were able to detect the areas in which emphysematous change was the most marked in the CT image, while the accumulation decrease was most remarkable in the ventilation SPECT image. Thus it was possible to obtain an accurate status of pulmonary emphysema, and our method was regarded as a useful technique. (author)

  10. Promoting peripheral myelin repair.

    Science.gov (United States)

    Zhou, Ye; Notterpek, Lucia

    2016-09-01

    Compared to the central nervous system (CNS), peripheral nerves have a remarkable ability to regenerate and remyelinate. This regenerative capacity to a large extent is dependent on and supported by Schwann cells, the myelin-forming glial cells of the peripheral nervous system (PNS). In a variety of paradigms, Schwann cells are critical in the removal of the degenerated tissue, which is followed by remyelination of newly-regenerated axons. This unique plasticity of Schwann cells has been the target of myelin repair strategies in acute injuries and chronic diseases, such as hereditary demyelinating neuropathies. In one approach, the endogenous regenerative capacity of Schwann cells is enhanced through interventions such as exercise, electrical stimulation or pharmacological means. Alternatively, Schwann cells derived from healthy nerves, or engineered from different tissue sources have been transplanted into the PNS to support remyelination. These transplant approaches can then be further enhanced by exercise and/or electrical stimulation, as well as by the inclusion of biomaterial engineered to support glial cell viability and neurite extension. Advances in our basic understanding of peripheral nerve biology, as well as biomaterial engineering, will further improve the functional repair of myelinated peripheral nerves. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Peripheral neuropathy in HIV: prevalence and risk factors

    Science.gov (United States)

    Evans, Scott R.; Ellis, Ronald J.; Chen, Huichao; Yeh, Tzu-min; Lee, Anthony J.; Schifitto, Giovanni; Wu, Kunling; Bosch, Ronald J.; McArthur, Justin C.; Simpson, David M.; Clifford, David B.

    2011-01-01

    Objectives To estimate neuropathic sign/symptom rates with initiation of combination antiretroviral therapy (cART) in HIV-infected ART-naive patients, and to investigate risk factors for: peripheral neuropathy and symptomatic peripheral neuropathy (SPN), recovery from peripheral neuropathy/SPN after neurotoxic ART (nART) discontinuation, and the absence of peripheral neuropathy/SPN while on nART. Design AIDS Clinical Trials Group (ACTG) Longitudinal Linked Randomized Trial participants who initiated cART in randomized trials for ART-naive patients were annually screened for symptoms/signs of peripheral neuropathy. ART use and disease characteristics were collected longitudinally. Methods Peripheral neuropathy was defined as at least mild loss of vibration sensation in both great toes or absent/hypoactive ankle reflexes bilaterally. SPN was defined as peripheral neuropathy and bilateral symptoms. Generalized estimating equation logistic regression was used to estimate associations. Results Two thousand, one hundred and forty-one participants were followed from January 2000 to June 2007. Rates of peripheral neuropathy/SPN at 3 years were 32.1/8.6% despite 87.1% with HIV-1RNA 400 copies/ml or less and 70.3% with CD4 greater than 350 cells/µl. Associations with higher odds of peripheral neuropathy included older patient age and current nART use. Associations with higher odds of SPN included older patient age, nART use, and history of diabetes mellitus. Associations with lower odds of recovery after nART discontinuation included older patient age. Associations with higher odds of peripheral neuropathy while on nART included older patient age and current protease inhibitor use. Associations with higher odds of SPN while on nART included older patient age, history of diabetes, taller height, and protease inhibitor use. Conclusion Signs of peripheral neuropathy remain despite virologic/immunologic control but frequently occurs without symptoms. Aging is a risk factor for

  12. Synthesis of fused tricyclic systems by thermal Cope rearrangement of furan-substituted vinyl cyclopropanes.

    Science.gov (United States)

    Klaus, Verena; Wittmann, Stéphane; Senn, Hans M; Clark, J Stephen

    2018-05-15

    A novel method for the stereoselective construction of hexahydroazuleno[4,5-b]furans from simple precursors has been developed. The route involves the use of our recently developed Brønsted acid catalysed cyclisation reaction of acyclic ynenones to prepare fused 1-furanyl-2-alkenylcyclopropanes that undergo highly stereoselective thermal Cope rearrangement to produce fused tricyclic products. Substrates possessing an E-alkene undergo smooth Cope rearrangement at 40 °C, whereas the corresponding Z-isomers do not react at this temperature. Computational studies have been performed to explain the difference in behaviour of the E- and Z-isomers in the Cope rearrangement reaction. The hexahydroazuleno[4,5-b]furans produced by Cope rearrangement have potential as advanced intermediates for the synthesis of members of the guaianolide family of natural products.

  13. Peripheral Vestibular System Disease in Vestibular Schwannomas

    DEFF Research Database (Denmark)

    Møller, Martin Nue; Hansen, Søren; Caye-Thomasen, Per

    2015-01-01

    density of the peripheral vestibular nerve branches, and atrophy of the neuroepithelium of the vestibular end organs. In cases with small tumors, peripheral disease occurred only in the tissue structures innervated by the specific nerve from which the tumor originated. CONCLUSION: Vestibular schwannomas...... are associated with distinctive disease of the peripheral vestibular tissue structures, suggesting anterograde degeneration and that dizziness in these patients may be caused by deficient peripheral vestibular nerve fibers, neurons, and end organs. In smaller tumors, a highly localized disease occurs, which...

  14. Enhancement of thermo-stability and product tolerance of Pseudomonas putida nitrile hydratase by fusing with self-assembling peptide.

    Science.gov (United States)

    Liu, Yi; Cui, Wenjing; Liu, Zhongmei; Cui, Youtian; Xia, Yuanyuan; Kobayashi, Michihiko; Zhou, Zhemin

    2014-09-01

    Self-assembling amphipathic peptides (SAPs) are the peptides that can spontaneously assemble into ordered nanostructures. It has been reported that the attachment of SAPs to the N- or C-terminus of an enzyme can benefit the thermo-stability of the enzyme. Here, we discovered that the thermo-stability and product tolerance of nitrile hydratase (NHase) were enhanced by fusing with two of the SAPs (EAK16 and ELK16). When the ELK16 was fused to the N-terminus of β-subunit, the resultant NHase (SAP-NHase-2) became an active inclusion body; EAK16 fused NHase in the N-terminus of β-subunit (SAP-NHase-1) and ELK16 fused NHase in the C-terminus of β-subunit (SAP-NHase-10) did not affect NHase solubility. Compared with the deactivation of the wild-type NHase after 30 min incubation at 50°C, SAP-NHase-1, SAP-NHase-2 and SAP-NHase-10 retained 45%, 30% and 50% activity; after treatment in the buffer containing 10% acrylamide, the wild-type retained 30% activity, while SAP-NHase-1, SAP-NHase-2 and SAP-NHase-10 retained 52%, 42% and 55% activity. These SAP-NHases with enhanced thermo-stability and product tolerance would be helpful for further industrial applications of the NHase. Copyright © 2014 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  15. A panchromatic anthracene-fused porphyrin sensitizer for dye-sensitized solar cells

    KAUST Repository

    Ball, James M.

    2012-01-01

    The development of ruthenium-free sensitizers which absorb light over a broad range of the solar spectrum is important for improving the power conversion efficiency of dye-sensitized solar cells. Here we study three chemically tailored porphyrin-based dyes. We show that by fusing the porphyrin core to an anthracene unit, we can extend the conjugation length and lower the optical gap, shifting the absorption spectrum into the near-infrared (NIR). All three dyes were tested in dye-sensitized solar cells, using both titanium dioxide and tin dioxide as the electron-transport material. Solar cells incorporating the anthracene-fused porphyrin dye exhibit photocurrent collection at wavelengths up to about 1100 nm, which is the longest reported for a porphyrin-based system. Despite extending the photon absorption bandwidth, device efficiency is found to be low, which is a common property of cells based on porphyrin dyes with NIR absorption. We show that in the present case the efficiency is reduced by inefficient electron injection into the oxide, as opposed to dye regeneration, and highlight some important design considerations for panchromatic sensitizers. © 2012 The Royal Society of Chemistry.

  16. Identification of FUSE-binding proteins as interacting partners of TIA proteins

    International Nuclear Information System (INIS)

    Rothe, Francoise; Gueydan, Cyril; Bellefroid, Eric; Huez, Georges; Kruys, Veronique

    2006-01-01

    TIA-1 and TIAR are closely related RNA-binding proteins involved in several mechanisms of RNA metabolism, including alternative hnRNA splicing and mRNA translation regulation. In particular, TIA-1 represses tumor necrosis factor (TNF) mRNA translation by binding to the AU-rich element (ARE) present in the mRNA 3' untranslated region. Here, we demonstrate that TIA proteins interact with FUSE-binding proteins (FBPs) and that fbp genes are co-expressed with tia genes during Xenopus embryogenesis. FBPs participate in various steps of RNA processing and degradation. In Cos cells, FBPs co-localize with TIA proteins in the nucleus and migrate into TIA-enriched cytoplasmic granules upon oxidative stress. Overexpression of FBP2-KH3 RNA-binding domain fused to EGFP induces the specific sequestration of TIA proteins in cytoplasmic foci, thereby precluding their nuclear accumulation. In cytosolic RAW 264.7 macrophage extracts, FBPs are found associated in EMSA to the TIA-1/TNF-ARE complex. Together, our results indicate that TIA and FBP proteins may thus be relevant biological involved in common events of RNA metabolism occurring both in the nucleus and the cytoplasm

  17. Transformation of Zwitterionic Pyridine Derivatives to a Spiro-Fused Ring System: Azoniabenzo[de]fluorine. Synthesis and Mechanistic Rationalization.

    Science.gov (United States)

    Palkó, Roberta; Egyed, Orsolya; Rokob, Tibor András; Bombicz, Petra; Riedl, Zsuzsanna; Hajós, György

    2015-01-02

    Reaction of aryl- and benzylsulfanopyridinium amidates bearing a methyl group in position 6 with 2 equiv of diphenylketene afforded a spiro-fused ring system: azoniabenzo[de]fluorine. By use of an excess amount of ketene, a distinct reaction was observed via which a 1H-pyrrolo[3,2-b]pyridin-2(3H)-one derivative was furnished. The structure of the tetracyclic spiro-fused ring system was unambiguously confirmed by X-ray diffraction, and its formation was rationalized by DFT calculations.

  18. Low-cost fused taper polymer optical fiber (LFT-POF) splitters for environmental and home-networking solution

    Science.gov (United States)

    Supian, L. S.; Ab-Rahman, Mohammad Syuhaimi; Harun, Mohd Hazwan; Gunab, Hadi; Sulaiman, Malik; Naim, Nani Fadzlina

    2017-08-01

    In visible optical communication over the multimode PMMA fibers, the overall cost of optical network can be reduced by deploying economical splitters for distributing the optical data signals from a point to multipoint in transmission network. The low-cost splitters shall have two main characteristics; good uniformity and high power efficiency. The most cost-effective and environmental friendly optical splitter having those characteristics have been developed. The device material is 100% purely based on the multimode step-index PMMA Polymer Optical Fiber (POF). The region which all fibers merged as single fiber is called as fused-taper POF. This ensures that all fibers are melted and fused properly. The results for uniformity and power efficiency of all splitters have been revealed by injecting red LED transmitter with 650 nm wavelength into input port while each end of output fibers measured by optical power meter. Final analysis shows our fused-taper splitter has low excess loss 0.53 dB and each of the output port has low insertion loss, which the average value is below 7 dB. In addition, the splitter has good uniformity that is 32:37:31% in which it is suitably used for demultiplexer fabrication.

  19. Synthesis of Conjugated Small Molecules and Polymers by a Palladium Catalyzed Cyclopentannulation Strategy: Towards New Organic Semiconductors

    Science.gov (United States)

    Bheemireddy, Sambasiva Reddy

    The utility of conjugated small molecules and polymers as organic semiconductors have seen a tremendous growth in research and development in academia as well as industry because of their processability and flexibility advantages in comparison to inorganic semiconductors. The extensive research over the years has produced a large number of p-type (hole conducting) and n-type (electron conducting) semiconductors that can be used to construct organic electronic devices. Of these materials, p-type semiconductors are more established and extensively studied because of the ease of preparation as well as their better general stability in comparison to n-type materials. Despite recent research into the development of n-type materials, fullerene (C60 and C 70) and its derivatives are still the predominant materials used as electron acceptors for OPV applications. By taking advantage of the electron accepting behavior of cyclopenta[hi]aceanthrylene fragment of C70, we have designed and synthesized new materials based on cyclopenta-fused polycyclic aromatic hydrocarbons (CP-PAHs). By using a newly developed palladium catalyzed cyclopentannulation methodology, 1,2,6,7- tetraarylcyclopenta[hi]aceanthrylenes were prepared by treating diarylethynylenes with 9,10-dibromoanthracene. Scholl cyclodehydrogenation was used to close the externally fused aryl groups to provide access to contorted 2,7,13,18- tetraalkoxytetrabenzo[f,h,r,t]rubicenes. The contortion provides access to more soluble materials than their planar counterparts but still ii allows significant pi-pi stacking between molecules. Using a modified palladium catalyzed cyclopentannulation polymerization followed by a cyclodehydrogenation reaction, a nonconventional synthesis of CP-PAH embedded ladder polymers was also achieved. These ladder polymers possess broad UV-Vis absorptions and narrow optical gaps of 1.17-1.29 eV. The synthesis of new donor-acceptor copolymers incorporating electron accepting 1,2,6,7- tetra(4

  20. Antioxidant Activity of Novel Fused Heterocyclic Compounds Derived from Tetrahydropyrimidine Derivative.

    Science.gov (United States)

    Salem, Marwa Sayed; Farhat, Mahmoud; Errayes, Asma Omar; Madkour, Hassan Mohamed Fawzy

    2015-01-01

    6-(Benzo[d][1,3]dioxol-5-yl)-4-oxo-2-thioxo-1,2,3,4-tetrahydropyrimidine-5-carbonitrile has been utilized for synthesis of the fused heterocyclic compounds namely thiazolopyrimidines, tetrazolopyrimidine, pyrimidoquinazoline, pyrimidothiazolopyrimidine, pyrimidothiazolotriazine and pyrrolothiazolopyrimidine derivatives. The newly synthesized compounds were characterized by IR, (1)H-NMR, (13)C-NMR, and mass spectral data. Antioxidant activities of all synthesized compounds were investigated.

  1. Fusing Open Source Intelligence and Handheld Situational Awareness - Benghazi Case Study

    Science.gov (United States)

    2014-10-01

    1 DM-0001694 Fusing Open Source Intelligence and Handheld Situational Awareness Benghazi Case Study Jeff Boleng, PhD Marc Novakouski Gene...command and control element at the CIA compound that would have been monitoring OSINT and other sources of intelligence before the attack and... Source Intelligence and Handheld Situational Awareness - Benghazi Case Study 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6

  2. Bilateral maxillary fused second and third molars: a rare occurrence

    OpenAIRE

    Liang, Rui-Zhen; Wu, Jin-Tao; Wu, You-Nong; Smales, Roger J; Hu, Ming; Yu, Jin-Hua; Zhang, Guang-Dong

    2012-01-01

    This case report describes the diagnosis and endodontic therapy of maxillary fused second and third molars, using cone-beam computed tomography (CBCT). A 31-year-old Chinese male, with no contributory medical or family/social history, presented with throbbing pain in the maxillary right molar area following an unsuccessful attempted tooth extraction. Clinical examination revealed what appeared initially to be a damaged large extra cusp on the buccal aspect of the distobuccal cusp of the secon...

  3. Benzene-fused BODIPYs: Synthesis and the impact of fusion mode

    KAUST Repository

    Ni, Yong

    2013-01-01

    BODIPY derivatives with one or two benzene units fused at different positions are prepared using novel synthetic methods. The resulting dye 1 shows deep red fluorescence with a large Stokes shift. Dyes 2 and 3 are reported for the first time and 3 exhibits near infrared absorption. The impact of benzannulation at different positions of BODIPY is discussed, and the geometry and electronic structure are studied by DFT calculations. This journal is © 2013 The Royal Society of Chemistry.

  4. Hypothyroidism: Can It Cause Peripheral Neuropathy?

    Science.gov (United States)

    Hypothyroidism: Can it cause peripheral neuropathy? Can hypothyroidism cause peripheral neuropathy and, if so, how is it treated? Answers from Todd B. Nippoldt, M.D. Hypothyroidism — a condition in which your ...

  5. A prototype hybrid 7π quinone-fused 1,3,2-dithiazolyl radical.

    Science.gov (United States)

    Decken, A; Mailman, A; Passmore, J; Rautiainen, J M; Scherer, W; Scheidt, E-W

    2011-01-28

    Reaction of 1,4-naphthoquinone and SNSMF(6) (M = As, Sb) in SO(2) solution in a 1 : 2 molar ratio led to the naphthoquinone fused 1,3,2-dithiazolylium salts, 3MF(6) quantitatively by multinuclear NMR (87% isolated yield of 3SbF(6)) via the cycloaddition and oxidative dehydrogenation chemistry of SNS(+) with formation of NH(4)SbF(6) and S(8). The product 3SbF(6) was fully characterized by IR, Raman, multinuclear {(1)H, (13)C, (14)N} NMR, elemental analysis, cyclic voltammetry and single crystal X-ray crystallography. The reduction of 3SbF(6) with ferrocene (Cp(2)Fe) in refluxing acetonitrile (CH(3)CN) led to the first isolation of a fused quinone-thiazyl radical, 3˙ in 73% yield. The prototype hybrid quinone-thiazyl radical 3˙ was fully characterized by IR, Raman microscopy, EI-MS, elemental analysis, solution and solid state EPR, magnetic susceptibility (2-370 K) and was found to form π*-π* dimers in the solid state as determined by single crystal X-ray crystallography. Furthermore, the thermal decomposition of 3˙ led to a novel quinone-fused 1,2,3,4-tetrathiine, 10 (x = 2) and the known 1,2,5-thiadiazole, 11. The energetics of the cycloadditon and oxidative dehydrogenation chemistry of SNS(+) and 1,4-naphthoquinone leading to 3SbF(6) were estimated in the gas phase and SO(2) solution by DFT calculations (PBE0/6-311G(d)) and lattice enthalpies obtained by the volume based thermodynamic (VBT) approach in the solid state. The gas phase ion energetics (ionization potential (IP) and electron affinity (EA)) of 3˙ are compared to related 1,3,2- and 1,2,3-dithiazolyl radicals.

  6. Endodontic treatment of developmental anomalies in posterior teeth: treatment of geminated/fused teeth--report of two cases.

    Science.gov (United States)

    Tsesis, I; Steinbock, N; Rosenberg, E; Kaufman, A Y

    2003-05-01

    Gemination or fusion is a rare occurrence in the mandibular posterior teeth. Endodontic treatment of these teeth needs special care and attention to the bizarre anatomy. The aim of this article is to describe the problems encountered and the strategy in treating such cases. Two cases of complex endodontic treatment of fused/geminated teeth are presented. The first is an 11-year-old girl with an anomalous 'double' first mandibular molar and premolar diagnosed as having necrotic pulp with chronic apical abscess of endodontic origin; the second is a 16-year-old boy with 'double' second and supernumerary mandibular molars, who was diagnosed with irreversible pulpitis. Both cases were treated successfully in multiple appointments. The common features and treatment modalities are discussed. Failure to diagnose fused/geminated teeth leads to misdiagnosis and a treatment plan that could cause permanent damage and tooth loss. Generally, there is communication between root canal systems of fused/geminated teeth which should be treated as one entity. Use of magnification is an important aid during treatment.

  7. Assay of uranium in fused salt cake generated at the natural uranium metal fuel fabrication plants by gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Kalsi, P.C.; Bhanu, A.U.; Sahoo, S.; Iyer, R.H.

    1986-01-01

    A passive gamma-ray spectroscopic method is employed for the assay of uranium in fused salt cake, a scrap produced at the natural uranium metal fuel fabrication plants. The method makes use of NaI(TI) detector coupled with a multichannel analyser. The 1 MeV gamma-ray of 238 U was used for the calibration. The calibration curve was made by counting synthetic mixtures made of U 3 O 8 powder, the heat treatment salt and iron in the form of fine powder. The uranium content in these synthetic mixtures was kept in the range of 1-11 per cent. 23 lots of the fused salt cake taken from three different batches of the salt cake were then analysed by this method. The uranium content of fused salt cake was found to be in the range of 1.70-11.43 per cent. To compare the gamma spectrometric results with a completely independent method, chemical analysis of all the fused salt cakes were also carried out. The NDA results were found to agree within ± 17 per cent with the chemical analysis results. (author)

  8. Peripheral ameloblastic fibro-odontoma or peripheral developing complex odontoma: report of a case

    DEFF Research Database (Denmark)

    Reibel, Jesper; Grønbæk, Anni Birgitte; Poulsen, Sven

    2011-01-01

    BACKGROUND. Peripheral (extraosseous) odontogenic tumors are rare. CASE REPORT. This report describes a case which illustrates the clinical and histopathological features of a lesion in an 8-year-old, healthy Caucasian girl that on purely morphological grounds would seem to be an ameloblastic fibro-odontoma......, but may represent a case of a peripheral developing complex odontoma. CONCLUSION. Conservative surgical enucleation of the lesion was followed by unbcomplicated healing and no recurrence was seen....

  9. Promoting peripheral myelin repair

    OpenAIRE

    Zhou, Ye; Notterpek, Lucia

    2016-01-01

    Compared to the central nervous system (CNS), peripheral nerves have a remarkable ability to regenerate and remyelinate. This regenerative capacity to a large extent is dependent on and supported by Schwann cells, the myelin-forming glial cells of the peripheral nervous system (PNS). In a variety of paradigms, Schwann cells are critical in the removal of the degenerated tissue, which is followed by remyelination of newly-regenerated axons. This unique plasticity of Schwann cells has been the ...

  10. Peripheral cemento-ossifying fibroma of maxilla.

    Science.gov (United States)

    Chatterjee, Anirban; Ajmera, Neha; Singh, Amit

    2010-07-01

    Peripheral cemento-ossifying fibroma is a reactive gingival overgrowth occurring frequently in anterior maxilla. It is a slow-growing benign tumor which may lead to pathologic migration and other periodontal problems, so it should be excised as soon as possible. The recurrence rate of peripheral cemento-ossifying fibroma is reported to be 8% to 20%, so a close postoperative follow-up is required. Herein, we are reporting a similar case of peripheral cemento-ossifying fibroma in the maxillary anterior region.

  11. Heat accumulation regime of femtosecond laser writing in fused silica and Nd:phosphate glass

    Energy Technology Data Exchange (ETDEWEB)

    Bukharin, M.A. [Moscow Institute of Physics and Technology, Moscow Region (Russian Federation); Optosystems Ltd., Troitsk, Moscow (Russian Federation); Khudyakov, D.V. [Optosystems Ltd., Troitsk, Moscow (Russian Federation); Physics Instrumentation Center of the General Physics Institute, Troitsk, Moscow (Russian Federation); Vartapetov, S.K. [Physics Instrumentation Center of the General Physics Institute, Troitsk, Moscow (Russian Federation)

    2015-04-01

    We investigated refractive index induced by direct femtosecond laser writing inside fused silica and Nd:phosphate glass in heat accumulation regime. Spatial profile and magnitude of induced refractive index were investigated at various pulse repetition rates and translation velocities. It was shown that the magnitude of induced refractive index significantly rises with decreasing in time interval between successive laser pulses below the time for thermal diffusion. Going from nonthermal regime to heat accumulation regime, we achieved induced refractive index growth from 4 x 10{sup -3} up to 6.5 x 10{sup -3} in fused silica and from -6 x 10{sup -3} to -9 x 10{sup -3} in Nd:phosphate glass. Aspect ratio of treated area decreased from 2.1 down to less than 1.5 without correcting optical elements. It was shown that in heat accumulation regime, the treated area was surrounded by region of alternatively changed refractive index with significant magnitude up to -2 x 10{sup -3}. Wide regions of decreased refractive index enable fabrication of depressed cladding waveguides. We demonstrated low-loss (0.3 dB/cm) tubular waveguide inside fused silica. For orthogonal polarizations of guiding light, we achieved a small difference between losses as 0.1 dB/cm using highly symmetric written tracks forming the cladding. The desired structure was simulated with the beam propagation method, and the results were in good agreement with experiment data. (orig.)

  12. Coaching Peripheral Vision Training for Soccer Athletes

    Science.gov (United States)

    Marques, Nelson Kautzner, Jr.

    2010-01-01

    Brazilian Soccer began developing its current emphasis on peripheral vision in the late 1950s, by initiative of coach of the Canto do Rio Football Club, in Niteroi, Rio de Janeiro, a pioneer in the development of peripheral vision training in soccer players. Peripheral vision training gained world relevance when a young talent from Canto do Rio,…

  13. Etching of fused silica fiber by metallic laser-induced backside wet etching technique

    Energy Technology Data Exchange (ETDEWEB)

    Vass, Cs., E-mail: vasscsaba@physx.u-szeged.hu [Department of Optics and Quantum Electronics, University of Szeged, H-6720 Szeged, Dóm tér 9 (Hungary); Kiss, B.; Kopniczky, J.; Hopp, B. [Department of Optics and Quantum Electronics, University of Szeged, H-6720 Szeged, Dóm tér 9 (Hungary)

    2013-08-01

    The tip of multimode fused silica fiber (core diameter: 550 μm) was etched by metallic laser-induced backside wet etching (M-LIBWE) method. Frequency doubled, Q-switched Nd:YAG laser (λ = 532 nm; τ{sub FWHM} = 8 ns) was used as laser source. The laser beam was coupled into the fiber by a fused silica lens with a focal length of 1500 mm. The other tip of the fiber was dipped into liquid gallium metallic absorber. The etching threshold fluence was measured to be 475 mJ/cm{sup 2}, while the highest fluence, which resulted etching without breaking the fiber, was 1060 mJ/cm{sup 2}. The progress of etching was followed by optical microscopy, and the etch rate was measured to be between 20 and 37 nm/pulse depending on the applied laser energy. The surface morphologies of the etched tips were studied by scanning electron microscopy. A possible application of the structured fibers was also tested.

  14. Etching of fused silica fiber by metallic laser-induced backside wet etching technique

    International Nuclear Information System (INIS)

    Vass, Cs.; Kiss, B.; Kopniczky, J.; Hopp, B.

    2013-01-01

    The tip of multimode fused silica fiber (core diameter: 550 μm) was etched by metallic laser-induced backside wet etching (M-LIBWE) method. Frequency doubled, Q-switched Nd:YAG laser (λ = 532 nm; τ FWHM = 8 ns) was used as laser source. The laser beam was coupled into the fiber by a fused silica lens with a focal length of 1500 mm. The other tip of the fiber was dipped into liquid gallium metallic absorber. The etching threshold fluence was measured to be 475 mJ/cm 2 , while the highest fluence, which resulted etching without breaking the fiber, was 1060 mJ/cm 2 . The progress of etching was followed by optical microscopy, and the etch rate was measured to be between 20 and 37 nm/pulse depending on the applied laser energy. The surface morphologies of the etched tips were studied by scanning electron microscopy. A possible application of the structured fibers was also tested.

  15. [Ultrasound-guided peripheral catheterization].

    Science.gov (United States)

    Salleras-Duran, Laia; Fuentes-Pumarola, Concepció

    2016-01-01

    Peripheral catheterization is a technique that can be difficult in some patients. Some studies have recently described the use of ultrasound to guide the venous catheterization. To describe the success rate, time required, complications of ultrasound-guided peripheral venous catheterization. and patients and professionals satisfaction The search was performed in databases (Medline-PubMed, Cochrane Library, CINAHL and Cuiden Plus) for studies published about ultrasound-guided peripheral venous catheterization performed on patients that provided results on the success of the technique, complications, time used, patient satisfaction and the type of professional who performed the technique. A total of 21 studies were included. Most of them get a higher success rate 80% in the catheterization ecoguide and time it is not higher than the traditional technique. The Technical complications analyzed were arterial puncture rates and lower nerve 10%. In all studies measuring and comparing patient satisfaction in the art ecoguide is greater. Various professional groups perform the technique. The use of ultrasound for peripheral pipes has a high success rate, complications are rare and the time used is similar to that of the traditional technique. The technique of inserting catheters through ultrasound may be learned by any professional group performing venipuncture. Finally, it gets underscores the high patient satisfaction with the use of this technique. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  16. Normal and sonographic anatomy of selected peripheral nerves. Part III: Peripheral nerves of the lower limb

    Directory of Open Access Journals (Sweden)

    Berta Kowalska

    2012-06-01

    Full Text Available The ultrasonographic examination is currently increasingly used in imaging peripheral nerves, serving to supplement the physical examination, electromyography and magnetic resonance imaging. As in the case of other USG imaging studies, the examination of peripheral nerves is non-invasive and well-tolerated by patients. The typical ultrasonographic picture of peripheral nerves as well as the examination technique have been discussed in part I of this article series, following the example of the median nerve. Part II of the series presented the normal anatomy and the technique for examining the peripheral nerves of the upper limb. This part of the article series focuses on the anatomy and technique for examining twelve normal peripheral nerves of the lower extremity: the iliohypogastric and ilioinguinal nerves, the lateral cutaneous nerve of the thigh, the pudendal, sciatic, tibial, sural, medial plantar, lateral plantar, common peroneal, deep peroneal and superficial peroneal nerves. It includes diagrams showing the proper positioning of the sonographic probe, plus USG images of the successively discussed nerves and their surrounding structures. The ultrasonographic appearance of the peripheral nerves in the lower limb is identical to the nerves in the upper limb. However, when imaging the lower extremity, convex probes are more often utilized, to capture deeply-seated nerves. The examination technique, similarly to that used in visualizing the nerves of upper extremity, consists of locating the nerve at a characteristic anatomic reference point and tracking it using the “elevator technique”. All 3 parts of the article series should serve as an introduction to a discussion of peripheral nerve pathologies, which will be presented in subsequent issues of the “Journal of Ultrasonography”.

  17. Reliability-oriented environmental thermal stress analysis of fuses in power electronics

    DEFF Research Database (Denmark)

    Bahman, A. S.; Iannuzzo, F.; Holmgaard, T.

    2017-01-01

    This paper investigates the thermo-mechanical stress experienced by axial lead fuses used in power electronics. Based on some experience, the approach used in this paper is pure thermal cycling, and the found failure mechanisms have been investigated through X-ray imaging. A two-step analysis, i...... element has been confirmed thanks to the analysis performed. Finally, the fatigue analysis is presented obtained by FEM-based fatigue tool....

  18. Peripheral Neuropathy – Clinical and Electrophysiological Considerations

    Science.gov (United States)

    Chung, Tae; Prasad, Kalpana; Lloyd, Thomas E.

    2013-01-01

    This article is a primer on the pathophysiology and clinical evaluation of peripheral neuropathy for the radiologist. Magnetic resonance neurography (MRN) has utility in the diagnosis of many focal peripheral nerve lesions. When combined with history, examination, electrophysiology, and laboratory data, future advancements in high-field MRN may play an increasingly important role in the evaluation of patients with peripheral neuropathy. PMID:24210312

  19. Thermal conductivity contrast measurement of Fused Silica exposed to low-energy femtosecond laser pulses

    NARCIS (Netherlands)

    Bellouard, Y.J.; Dugan, M.; Said, A.A.; Bado, P.

    2006-01-01

    Femtosecond laser irradiation has various noticeable effects on fused silica. Of particular interest, pulses with energy levels below the ablation threshold can locally increase the refractive index and the material etching selectivity to hydrofluoric acid. The mechanism responsible for these

  20. The challenges and beauty of peripheral nerve regrowth.

    Science.gov (United States)

    Zochodne, Douglas W

    2012-03-01

    This review provides an overview of selected aspects of peripheral nerve regeneration and potential avenues to explore therapeutically. The overall coordinated and orchestrated pattern of recovery from peripheral nerve injury has a beauty of execution and progress that rivals all other forms of neurobiology. It involves changes at the level of the perikaryon, coordination with important peripheral glial partners, the Schwann cells, a controlled inflammatory response, and growth that overcomes surprising intrinsic roadblocks. Both regenerative axon growth and collateral sprouting encompass fascinating aspects of this story. Better understanding of peripheral nerve regeneration may also lead to enhanced central nervous system recovery. © 2012 Peripheral Nerve Society.

  1. Odontogenic keratocyst: a peripheral variant.

    Science.gov (United States)

    Vij, H; Vij, R; Gupta, V; Sengupta, S

    2011-01-01

    Odontogenic keratocyst, which is developmental in nature, is an intraosseous lesion though on rare occasions it may occur in an extraosseous location. The extraosseous variant is referred to as peripheral odontogenic keratocyst. Though, clinically, peripheral odontogenic keratocyst resembles the gingival cyst of adults, it has histologic features that are pathognomonic of odontogenic keratocyst. This article presents a case of this uncommon entity.

  2. Nonsurgical endodontic retreatment of fused teeth with transposition: a case report

    Directory of Open Access Journals (Sweden)

    Miguel Agostinho Beco Pinto Cardoso

    2016-05-01

    Full Text Available Tooth transposition is a disorder in which a permanent tooth develops and erupts in the normal position of another permanent tooth. Fusion and gemination are developmental disturbances presenting as the union of teeth. This article reports the nonsurgical retreatment of a very rare case of fused teeth with transposition. A patient was referred for endodontic treatment of her maxillary left first molar in the position of the first premolar, which was adjacent to it on the distobuccal side. Orthopantomography and periapical radiography showed two crowns sharing the same root, with a root canal treatment and an associated periapical lesion. Tooth fusion with transposition of a maxillary molar and a premolar was diagnosed. Nonsurgical endodontic retreatment was performed. At four yr follow-up, the tooth was asymptomatic and the radiolucency around the apical region had decreased, showing the success of our intervention. The diagnosis and treatment of fused teeth require special attention. The canal system should be carefully explored to obtain a full understanding of the anatomy, allowing it to be fully cleaned and obturated. Thermoplastic techniques were useful in obtaining hermetic obturation. A correct anatomical evaluation improves the set of treatment options under consideration, leading to a higher likelihood of esthetically and functionally successful treatment.

  3. An Empirical Method to Fuse Partially Overlapping State Vectors for Distributed State Estimation

    NARCIS (Netherlands)

    Sijs, J.; Hanebeck, U.; Noack, B.

    2013-01-01

    State fusion is a method for merging multiple estimates of the same state into a single fused estimate. Dealing with multiple estimates is one of the main concerns in distributed state estimation, where an estimated value of the desired state vector is computed in each node of a networked system.

  4. Fused fiber components for "eye-safe" spectral region around 2μm

    Czech Academy of Sciences Publication Activity Database

    Písařík, M.; Peterka, Pavel; Zvánovec, S.; Baravets, Yauhen; Todorov, Filip; Kašík, Ivan; Honzátko, Pavel

    2014-01-01

    Roč. 46, č. 4 (2014), s. 603-611 ISSN 0306-8919 R&D Projects: GA ČR(CZ) GAP205/11/1840; GA MPO FR-TI4/734 Grant - others:COST(XE) MP1204 Institutional support: RVO:67985882 Keywords : High slope efficiency * Material processing * Fused biconical tapered method Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 0.987, year: 2014

  5. Perylene-fused BODIPY dye with near-IR absorption/emission and high photostability

    KAUST Repository

    Jiao, Chongjun

    2011-02-18

    A N-annulated perylene unit was successfully fused to the meso-and β-positions of a boron dipyrromethene (BODIPY) core. The newly synthesized BODIPY dye 1b exhibits intensified near-infrared (NIR) absorption and the longest emission maximum ever observed for all BODIPY derivatives. In addition, this dye possesses excellent solubility and photostability, beneficial to practical applications. © 2011 American Chemical Society.

  6. Perylene-fused BODIPY dye with near-IR absorption/emission and high photostability

    KAUST Repository

    Jiao, Chongjun; Huang, Kuo-Wei; Wu, Jishan

    2011-01-01

    A N-annulated perylene unit was successfully fused to the meso-and β-positions of a boron dipyrromethene (BODIPY) core. The newly synthesized BODIPY dye 1b exhibits intensified near-infrared (NIR) absorption and the longest emission maximum ever observed for all BODIPY derivatives. In addition, this dye possesses excellent solubility and photostability, beneficial to practical applications. © 2011 American Chemical Society.

  7. A new method for synthesizing fluid inclusions in fused silica capillaries containing organic and inorganic material

    Science.gov (United States)

    Chou, I.-Ming; Song, Yucai; Burruss, R. C.

    2008-11-01

    Considerable advances in our understanding of physicochemical properties of geological fluids and their roles in many geological processes have been achieved by the use of synthetic fluid inclusions. We have developed a new method to synthesize fluid inclusions containing organic and inorganic material in fused silica capillary tubing. We have used both round (0.3 mm OD and 0.05 or 0.1 mm ID) and square cross-section tubing (0.3 × 0.3 mm with 0.05 × 0.05 mm or 0.1 × 0.1 mm cavities). For microthermometric measurements in a USGS-type heating-cooling stage, sample capsules must be less than 25 mm in length. The square-sectioned capsules have the advantage of providing images without optical distortion. However, the maximum internal pressure ( P; about 100 MPa at 22 °C) and temperature ( T; about 500 °C) maintained by the square-sectioned capsules are less than those held by the round-sectioned capsules (about 300 MPa at room T, and T up to 650 °C). The fused silica capsules can be applied to a wide range of problems of interest in fluid inclusion and hydrothermal research, such as creating standards for the calibration of thermocouples in heating-cooling stages and frequency shifts in Raman spectrometers. The fused silica capsules can also be used as containers for hydrothermal reactions, especially for organic samples, including individual hydrocarbons, crude oils, and gases, such as cracking of C 18H 38 between 350 and 400 °C, isotopic exchanges between C 18H 38 and D 2O and between C 19D 40 and H 2O at similar temperatures. Results of these types of studies provide information on the kinetics of oil cracking and the changes of oil composition under thermal stress. When compared with synthesis of fluid inclusions formed by healing fractures in quartz or other minerals or by overgrowth of quartz at elevated P- T conditions, the new fused-silica method has the following advantages: (1) it is simple; (2) fluid inclusions without the presence of water can be

  8. Towards a culturally independent participatory design method: Fusing game elements into the design process

    DEFF Research Database (Denmark)

    Jensen, Mika Yasuoka; Nakatani, Momoko; Ohno, Takehiko

    2013-01-01

    Historically, Participatory Design (PD) was introduced and applied in the Scandinavian and American context as a practical design method for collective creativity and stakeholder involvement. In this paper, by fusing game elements into PD, we suggest a first step towards a culturally independent ...... imply that the introduction of game elements allows PD to be effectively utilized in culturally diverse settings.......Historically, Participatory Design (PD) was introduced and applied in the Scandinavian and American context as a practical design method for collective creativity and stakeholder involvement. In this paper, by fusing game elements into PD, we suggest a first step towards a culturally independent PD...... method called the ICT Service Design Game to ease the prevailing concern that PD has limited applicability in other cultural settings. We conduct four experiments on ICT Service Design Game in Scandinavia and Asia to evaluate its feasibility. The experiments identify some differences in the PD process...

  9. Endodontic treatment of a fused tooth. Report of a case.

    Science.gov (United States)

    Gallottini, L; Barbato Bellatini, R C; Migliau, G

    2007-01-01

    Dental fusion, a rare developmental anomaly present in 0.2% of the general population, consists of the union of two teeth originating from two different tooth germs. The irregular coronal morphology and the complex endodontic anatomy, characterized by the partial or total union of the pulp chambers, together with the peculiarity of the root canal systems, make diagnosis, therapy and rehabilitation difficult. The authors describe the endodontic treatment of a permanent lower second molar fused with a third molar and having four root canals.

  10. Synthesis of cyclopentadiene-fused chromanones via one-pot multicomponent reactions.

    Science.gov (United States)

    Ghandi, Mehdi; Ghomi, Ali-Tabatabaei; Kubicki, Maciej

    2013-03-15

    We have developed one-pot method for the synthesis of functionalized novel cyclopentadiene-fused chromanone scaffolds. A variety of 4-oxo-2,4-dihydrocyclopenta[c]chromene-1,2-dicarboxylates were obtained in moderate to good yields via condensation of 2-hydroxybenzaldehydes and ethyl acetoacetate with 1:1 acetylenecarboxylate-isocyanides in toluene. These reactions presumably proceed via reaction of the in situ generated 3-acetyl-2H-chromen-2-ones with acetylenecarboxylate-isocyanide zwitterionic intermediates through Michael addition/intramolecular cyclization and double [1,5] acyl shift rearrangement cascade.

  11. Measurements of effective noise temperature in fused silica fiber violin modes

    Energy Technology Data Exchange (ETDEWEB)

    Bilenko, I.A.; Lourie, S.L

    2002-11-25

    The results of measurements of the effective noise temperature in fused silica fiber violin modes are presented. In these measurements the fibers were stressed and value of the effective noise temperature was obtained by direct observation of oscillations in the fundamental violin modes of several samples. Measured values indicate that effective noise temperature does not exceed the room temperature significantly. This result is important for the design of the advanced gravitational wave antennae.

  12. Synovial sarcoma mimicking benign peripheral nerve sheath tumor

    Energy Technology Data Exchange (ETDEWEB)

    Larque, Ana B.; Nielsen, G.P.; Chebib, Ivan [Massachusetts General Hospital and Harvard Medical School, Department of Pathology, Boston, MA (United States); Bredella, Miriam A. [Massachusetts General Hospital and Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2017-11-15

    To assess the radiographic and clinicopathologic features of synovial sarcoma of the nerve that were clinically or radiologically interpreted as benign peripheral nerve sheath tumor. Five patients with synovial sarcoma arising from the peripheral nerve and interpreted clinically and radiologically as peripheral nerve sheath tumors were identified. Clinicopathologic and imaging features were evaluated. There were three females and two males, ranging in age from 28 to 50 (mean 35.8) years. Most patients (4/5) complained of a mass, discomfort or pain. MR images demonstrated a heterogeneous, enhancing, soft tissue mass contiguous with the neurovascular bundle. On histologic examination, most tumors were monophasic synovial sarcoma (4/5). At the time of surgery, all tumors were noted to arise along or within a peripheral nerve. All patients were alive with no evidence of disease with median follow-up of 44 (range 32-237) months. For comparison, approximately 775 benign peripheral nerve sheath tumors of the extremities were identified during the same time period. Primary synovial sarcoma of the nerve can mimic peripheral nerve sheath tumors clinically and on imaging and should be included in the differential diagnosis for tumors arising from peripheral nerves. (orig.)

  13. Peripheral refractive correction and automated perimetric profiles.

    Science.gov (United States)

    Wild, J M; Wood, J M; Crews, S J

    1988-06-01

    The effect of peripheral refractive error correction on the automated perimetric sensitivity profile was investigated on a sample of 10 clinically normal, experienced observers. Peripheral refractive error was determined at eccentricities of 0 degree, 20 degrees and 40 degrees along the temporal meridian of the right eye using the Canon Autoref R-1, an infra-red automated refractor, under the parametric conditions of the Octopus automated perimeter. Perimetric sensitivity was then undertaken at these eccentricities (stimulus sizes 0 and III) with and without the appropriate peripheral refractive correction using the Octopus 201 automated perimeter. Within the measurement limits of the experimental procedures employed, perimetric sensitivity was not influenced by peripheral refractive correction.

  14. Peripheral facial nerve dysfunction: CT evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Disbro, M.A.; Harnsberger, H.R.; Osborn, A.G.

    1985-06-01

    Peripheral facial nerve dysfunction may have a clinically apparent or occult cause. The authors reviewed the clinical and radiographic records of 36 patients with peripheral facial nerve dysfunction to obtain information on the location of the suspected lesion and the number, sequence, and type of radiographic evaluations performed. Inadequate clinical evaluations before computed tomography (CT) was done and unnecessary CT examinations were also noted. They have suggested a practical clinical and radiographic scheme to evaluate progressive peripheral facial dysfunction with no apparent cause. If this scheme is applied, unnecessary radiologic tests and delays in diagnosis and treatment may be avoided.

  15. Peripheral nerve conduits: technology update

    Science.gov (United States)

    Arslantunali, D; Dursun, T; Yucel, D; Hasirci, N; Hasirci, V

    2014-01-01

    Peripheral nerve injury is a worldwide clinical problem which could lead to loss of neuronal communication along sensory and motor nerves between the central nervous system (CNS) and the peripheral organs and impairs the quality of life of a patient. The primary requirement for the treatment of complete lesions is a tension-free, end-to-end repair. When end-to-end repair is not possible, peripheral nerve grafts or nerve conduits are used. The limited availability of autografts, and drawbacks of the allografts and xenografts like immunological reactions, forced the researchers to investigate and develop alternative approaches, mainly nerve conduits. In this review, recent information on the various types of conduit materials (made of biological and synthetic polymers) and designs (tubular, fibrous, and matrix type) are being presented. PMID:25489251

  16. Explosively formed fuse opening switches for use in flux-compression generator circuits

    International Nuclear Information System (INIS)

    Goforth, J.H.; Marsh, S.P.

    1990-01-01

    Explosive-driven magnetic flux compression generators (explosive generators) provide for the generation of large amounts of energy compactly stored in a magnetic field. Opening switches for use in explosive generator circuits allow the energy to be used for applications requiring higher power than can be developed by the generators themselves. The authors have developed a type of opening switch that they describe as an explosively formed fuse (EEF). These switches are well suited to explosive generator circuits and provide a considerable enhancement of explosive pulsed-power capability. The authors first experiments with explosively formed fuses occurred while attempting to utilize the enhanced pressure developed in the high-pressure interaction between two detonation fronts. In these tests they attempted to use the interaction to sever conducting plates along lines perpendicular to current flow. The technique worked to some extent, and to ascertain how much advantage was gained from the high-pressure interaction, they substituted an areal detonation in place of the discrete lines required to produce lines of interaction. This paper describes the authors development effort, the state of the art, and the different manifestations of their technique

  17. Prime-Boost Vaccination Using Chemokine-Fused gp120 DNA and HIV Envelope Peptides Activates Both Immediate and Long-Term Memory Cellular Responses in Rhesus Macaques

    Directory of Open Access Journals (Sweden)

    Hong Qin

    2010-01-01

    Full Text Available HIV vaccine candidates with improved immunogenicity and induction of mucosal T-cell immunity are needed. A prime-boost strategy using a novel HIV glycoprotein 120 DNA vaccine was employed to immunize rhesus macaques. The DNA vaccine encoded a chimeric gp120 protein in fusion with monocyte chemoattractant protein-3, which was hypothesized to improve the ability of antigen-presenting cells to capture viral antigen through chemokine receptor-mediated endocytosis. DNA vaccination induced virus-reactive T cells in peripheral blood, detectable by T cell proliferation, INFγ ELISPOT and sustained IL-6 production, without humoral responses. With a peptide-cocktail vaccine containing a set of conserved polypeptides of HIV-1 envelope protein, given by nasogastric administration, primed T-cell immunity was significantly boosted. Surprisingly, long-term and peptide-specific mucosal memory T-cell immunity was detected in both vaccinated macaques after one year. Therefore, data from this investigation offer proof-of-principle for potential effectiveness of the prime-boost strategy with a chemokine-fused gp120 DNA and warrant further testing in the nonhuman primate models for developing as a potential HIV vaccine candidate in humans.

  18. Laser induced damage and fracture in fused silica vacuum windows

    International Nuclear Information System (INIS)

    Campbell, J.H.; Hurst, P.A.; Heggins, D.D.; Steele, W.A.; Bumpas, S.E.

    1996-11-01

    Laser-induced damage, that initiates catastrophic fracture, has been observed in large (≤61 cm dia) fused silica lenses that also serve as vacuum barriers in Nova and Beamlet lasers. If the elastic stored energy in the lens is high enough, the lens will fracture into many pieces (implosion). Three parameters control the degree of fracture in the vacuum barrier window: elastic stored energy (tensile stress), ratio of window thickness to flaw depth, and secondary crack propagation. Fracture experiments were conducted on 15-cm dia fused silica windows that contain surface flaws caused by laser damage. Results, combined with window failure data on Beamlet and Nova, were used to develop design criteria for a ''fail-safe'' lens (that may catastrophically fracture but not implode). Specifically, the window must be made thick enough so that the peak tensile stress is less than 500 psi (3.4 MPa) and the thickness/critical flaw size is less than 6. The air leak through the window fracture and into the vacuum must be rapid enough to reduce the load on the window before secondary crack growth occurs. Finite element stress calculations of a window before and immediately following fracture into two pieces show that the elastic stored energy is redistributed if the fragments ''lock'' in place and thereby bridge the opening. In such cases, the peak stresses at the flaw site can increase, leading to further (i.e. secondary) crack growth

  19. Toxicity of inhaled 90Y in fused clay particles in beagle dogs. VI

    International Nuclear Information System (INIS)

    Hobbs, C.H.; Chiffelle, T.L.; Hahn, F.F.; Jones, R.K.; Mauderly, J.L.; McClellan, R.O.; Pickrell, J.A.

    1974-01-01

    Studies on the metabolism, dosimetry, and effects of inhaled 90 Y in fused clay in the Beagle dog are being continued to assess the consequences of inhalation of an energetic beta emitter that has a short effective half-life in the lung. A radiation dose pattern study in which 12 dogs were sacrificed in pairs at 0, 2, 4, 6, 8, and 12 days post-inhalation exposure has been completed. A longevity study in which 89 dogs have been exposed to 90 Y fused clay with initial lung burdens ranging from 80 to 5200 μCi/kg body weight and 12 control dogs were exposed to stable yttrium in fused clay is in progress. The 90 Y was retained in lung with a half-life similar to its physical half-life (64 hours) and with only small quantities translocated to tracheobronchial lymph nodes, skeleton, and liver. The infinite radiation doses to lung, tracheobronchial lymph nodes, skeleton, and liver for an initial lung burden of 100 μCi 90 Y/kg of body weight were estimated to be 1600, 170, 0.54, and 0.38 rads, respectively. Thirty-eight of 39 dogs with doses to lung from 9300 to 70,000 rads have died at 7.5 to 903 days post-exposure. The one surviving dog in this dose range has radiographic evidence of pulmonary fibrosis at 1316 days post-exposure. All the dogs that died had radiation pneumonitis. The dog that died at 903 days post-exposure with a dose to lung of 11,000 rads also had 2 small pulmonary adenomas. Fifty exposed dogs with doses to lung of 1300 to 7900 rads are surviving with no significant abnormalities at 1278 to 1834 days post-exposure and will be studied for the remainder of their lifespan. (U.S.)

  20. A COMPARISON OF THE TENSILE STRENGTH OF PLASTIC PARTS PRODUCED BY A FUSED DEPOSITION MODELING DEVICE

    Directory of Open Access Journals (Sweden)

    Juraj Beniak

    2015-12-01

    Full Text Available Rapid Prototyping systems are nowadays increasingly used in many areas of industry, not only for producing design models but also for producing parts for final use. We need to know the properties of these parts. When we talk about the Fused Deposition Modeling (FDM technique and FDM devices, there are many possible settings for devices and models which could influence the properties of a final part. In addition, devices based on the same principle may use different operational software for calculating the tool path, and this may have a major impact. The aim of this paper is to show the tensile strength value for parts produced from different materials on the Fused Deposition Modeling device when the horizontal orientation of the specimens is changed.

  1. Solubility of fused silica in sub- and supercritical water: Estimation from a thermodynamic model

    Czech Academy of Sciences Publication Activity Database

    Karásek, Pavel; Šťavíková, Lenka; Planeta, Josef; Hohnová, Barbora; Roth, Michal

    2013-01-01

    Roč. 83, NOV (2013), s. 72-77 ISSN 0896-8446 R&D Projects: GA ČR(CZ) GAP106/12/0522 Institutional support: RVO:68081715 Keywords : amorphous silica * fused silica * supercritical water * aqueous solubility Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 2.571, year: 2013

  2. Distance Estimation by Fusing Radar and Monocular Camera with Kalman Filter

    OpenAIRE

    Feng, Yuxiang; Pickering, Simon; Chappell, Edward; Iravani, Pejman; Brace, Christian

    2017-01-01

    The major contribution of this paper is to propose a low-cost accurate distance estimation approach. It can potentially be used in driver modelling, accident avoidance and autonomous driving. Based on MATLAB and Python, sensory data from a Continental radar and a monocular dashcam were fused using a Kalman filter. Both sensors were mounted on a Volkswagen Sharan, performing repeated driving on a same route. The established system consists of three components, radar data processing, camera dat...

  3. Synthesis and Microbiological Activity of Some Newly Synthesized Derivatives of 2-Oxo-2H-chromen-2-one

    OpenAIRE

    Daci-Ajvazi, Majlinda; Govori, Sevdije; Omeragiq, Shuhreta

    2011-01-01

    By the action of 2-amino-5-methylthio-1,3,4-thiadiazole, 3-amino-5-methylisoxazole, 2-amino-6-fluorobenzothiazole, 2-amino-5-chloropyridine, respectively, on 4-chloro-2-oxo-2H-chromene-3-sulfonyl chloride, the corresponding 9-methylthio-7,7-dioxo-7,7a-dihydro-5-oxo-7λ6,10-dithia-8,11-diaza-cyclopenta[b] phenantren-6-one, 9-methyl-7,7-dioxo-7H-5,8-dioxa-7λ6-thia-7a,11-diaza-cyclopenta[b] phenantren-6-one, 9-fluoro-7,7-dioxo-7H-5-oxa-7λ6,12-dithia-7a,13-diaza-indeno[1,2-b] phenantren-6-one and ...

  4. Peripheral facial weakness (Bell's palsy).

    Science.gov (United States)

    Basić-Kes, Vanja; Dobrota, Vesna Dermanović; Cesarik, Marijan; Matovina, Lucija Zadro; Madzar, Zrinko; Zavoreo, Iris; Demarin, Vida

    2013-06-01

    Peripheral facial weakness is a facial nerve damage that results in muscle weakness on one side of the face. It may be idiopathic (Bell's palsy) or may have a detectable cause. Almost 80% of peripheral facial weakness cases are primary and the rest of them are secondary. The most frequent causes of secondary peripheral facial weakness are systemic viral infections, trauma, surgery, diabetes, local infections, tumor, immune disorders, drugs, degenerative diseases of the central nervous system, etc. The diagnosis relies upon the presence of typical signs and symptoms, blood chemistry tests, cerebrospinal fluid investigations, nerve conduction studies and neuroimaging methods (cerebral MRI, x-ray of the skull and mastoid). Treatment of secondary peripheral facial weakness is based on therapy for the underlying disorder, unlike the treatment of Bell's palsy that is controversial due to the lack of large, randomized, controlled, prospective studies. There are some indications that steroids or antiviral agents are beneficial but there are also studies that show no beneficial effect. Additional treatments include eye protection, physiotherapy, acupuncture, botulinum toxin, or surgery. Bell's palsy has a benign prognosis with complete recovery in about 80% of patients, 15% experience some mode of permanent nerve damage and severe consequences remain in 5% of patients.

  5. CT characteristics of peripheral organizing pneumonia

    International Nuclear Information System (INIS)

    Yang, Seong Oh; Choi, Chul Soon; Kim, Myung Joon; Lee, Kyung Soo; Choi, Hyung Sik; Jun, Young Hwan; Park, Yong Koo

    1988-01-01

    Diagnostic dilemma of persistent mass-forming parenchymal opacity in the lung periphery occurs occasionally in the realm of diagnostic radiology. Until recently, literature on the role of computed tomography in peripheral organizing pneumonia, which is difficult to differentiate from malignancy, has little been published. We experienced one case of pathologically proven organizing pneumonia diagnosed preoperatively by chest CT. When it comes to solitary peripheral mass density in the lung, we think that CT can be proved useful in the diagnosis of benign organizing pneumonia by showing regular and smoothly corrugate margin, peripheral contrast enhancement with inner low density, and air-trapping by intervening normal lung parenchyma.

  6. Laser peripheral iridoplasty for angle-closure.

    Science.gov (United States)

    Ng, Wai Siene; Ang, Ghee Soon; Azuara-Blanco, Augusto

    2012-02-15

    Angle-closure glaucoma is a leading cause of irreversible blindness in the world. Treatment is aimed at opening the anterior chamber angle and lowering the IOP with medical and/or surgical treatment (e.g. trabeculectomy, lens extraction). Laser iridotomy works by eliminating pupillary block and widens the anterior chamber angle in the majority of patients. When laser iridotomy fails to open the anterior chamber angle, laser iridoplasty may be recommended as one of the options in current standard treatment for angle-closure. Laser peripheral iridoplasty works by shrinking and pulling the peripheral iris tissue away from the trabecular meshwork. Laser peripheral iridoplasty can be used for crisis of acute angle-closure and also in non-acute situations.   To assess the effectiveness of laser peripheral iridoplasty in the treatment of narrow angles (i.e. primary angle-closure suspect), primary angle-closure (PAC) or primary angle-closure glaucoma (PACG) in non-acute situations when compared with any other intervention. In this review, angle-closure will refer to patients with narrow angles (PACs), PAC and PACG. We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2011, Issue 12), MEDLINE (January 1950 to January 2012), EMBASE (January 1980 to January 2012), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to January 2012), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). There were no date or language restrictions in the electronic searches for trials. The electronic databases were last searched on 5 January 2012. We included only randomised controlled trials (RCTs) in this review. Patients with narrow angles, PAC or PACG were eligible. We excluded studies that included only patients with acute presentations

  7. [Peripheral retinal degenerations--treatment recommendations].

    Science.gov (United States)

    Joussen, A M; Kirchhof, B

    2004-10-01

    This report reviews the clinical appearance of degenerative diseases of the peripheral retina in relationship to the risk of developing a rhegmatogenous retinal detachment. We present recommendations for preventive treatment in eyes at increased risk of developing retinal detachment. Retinal degenerations are common lesions involving the peripheral retina but most of them are clinically insignificant. Lattice degeneration, degenerative retinoschisis, cystic retinal tufts, and very rarely zonular traction tufts can result in rhegmatogenous retinal detachment. Therefore, these lesions have been considered for prophylactic treatment; however, adequate studies have not been performed to date. Most of the peripheral retinal degenerations may not require treatment except in rare, high-risk situations. According to current knowledge there is no higher incidence of secondary pucker or other side effects after laser coagulation. Therefore, generous laser indication is recommended if risk factors apply.

  8. Analysis of mandibular second molars with fused roots and shallow radicular grooves by using micro-computed tomography.

    Science.gov (United States)

    Amoroso-Silva, Pablo; De Moraes, Ivaldo Gomes; Marceliano-Alves, Marilia; Bramante, Clovis Monteiro; Zapata, Ronald Ordinola; Hungaro Duarte, Marco Antonio

    2018-01-01

    This study aimed to describe the morphological and morphometric aspects of fused mandibular second molars with radicular shallow grooves using micro-computed tomography (CT). Eighty-eight mandibular second molars with fused roots were scanned in a micro-CT scanner at a voxel size of 19.6 μm. After reconstruction, only molars without C-shaped roots and presenting shallow radicular grooves were selected. 30 molars were chosen for further analysis. Canal cross-sections were classified according to Fan's modified classification (C1, C2, C3, and C4) and morphometric parameters at the apical region, examination of accessory foramina and tridimensional configuration were evaluated. Three-dimensional reconstructions indicated a higher prevalence of merging type ( n = 22). According to Fan's modified classification, the C4 configuration was predominant in the 3 apical mm. Roundness median values revealed a more round-shaped canals at 3 mm (0.72) than at 2 (0.63) and 1 (0.61) mm from the apex. High values of major and minor diameters were observed in the canals of these evaluated sections. In addition, few accessory apical foramina were observed at 1 and 2 mm from the apex. The average distance between last accessory foramina and the anatomic apex was 1.17 mm. A less complex internal anatomy is found when a mandibular second molar presents fused roots with shallow radicular grooves. The merging type canal was frequently observed. Moreover, the C4 configuration was predominant at a point 3 mm from the apex and presented rounded canals, large apical diameters, and few accessory foramina. The cervical and middle thirds presented C3 and C1 canal configurations most frequently. A minor morphological complexity is found when fused mandibular second molars present shallow radicular grooves.

  9. Understanding error generation in fused deposition modeling

    Science.gov (United States)

    Bochmann, Lennart; Bayley, Cindy; Helu, Moneer; Transchel, Robert; Wegener, Konrad; Dornfeld, David

    2015-03-01

    Additive manufacturing offers completely new possibilities for the manufacturing of parts. The advantages of flexibility and convenience of additive manufacturing have had a significant impact on many industries, and optimizing part quality is crucial for expanding its utilization. This research aims to determine the sources of imprecision in fused deposition modeling (FDM). Process errors in terms of surface quality, accuracy and precision are identified and quantified, and an error-budget approach is used to characterize errors of the machine tool. It was determined that accuracy and precision in the y direction (0.08-0.30 mm) are generally greater than in the x direction (0.12-0.62 mm) and the z direction (0.21-0.57 mm). Furthermore, accuracy and precision tend to decrease at increasing axis positions. The results of this work can be used to identify possible process improvements in the design and control of FDM technology.

  10. Radio-guided sentinel lymph node identification by lymphoscintigraphy fused with an anatomical vector profile: clinical applications.

    Science.gov (United States)

    Niccoli Asabella, A; Antonica, F; Renna, M A; Rubini, D; Notaristefano, A; Nicoletti, A; Rubini, G

    2013-12-01

    To develop a method to fuse lymphoscintigraphic images with an adaptable anatomical vector profile and to evaluate its role in the clinical practice. We used Adobe Illustrator CS6 to create different vector profiles, we fused those profiles, using Adobe Photoshop CS6, with lymphoscintigraphic images of the patient. We processed 197 lymphoscintigraphies performed in patients with cutaneous melanomas, breast cancer or delayed lymph drainage. Our models can be adapted to every patient attitude or position and contain different levels of anatomical details ranging from external body profiles to the internal anatomical structures like bones, muscles, vessels, and lymph nodes. If needed, more new anatomical details can be added and embedded in the profile without redrawing them, saving a lot of time. Details can also be easily hidden, allowing the physician to view only relevant information and structures. Fusion times are about 85 s. The diagnostic confidence of the observers increased significantly. The validation process showed a slight shift (mean 4.9 mm). We have created a new, practical, inexpensive digital technique based on commercial software for fusing lymphoscintigraphic images with built-in anatomical reference profiles. It is easily reproducible and does not alter the original scintigraphic image. Our method allows a more meaningful interpretation of lymphoscintigraphies, an easier recognition of the anatomical site and better lymph node dissection planning.

  11. 3D printing of CNT- and graphene-based conductive polymer nanocomposites by fused deposition modeling

    NARCIS (Netherlands)

    Gnanasekaran, K.; Heijmans, T.; van Bennekom, S.; Woldhuis, H.; Wijnia, S.; de With, G.; Friedrich, H.

    2017-01-01

    Fused deposition modeling (FDM) is limited by the availability of application specific functional materials. Here we illustrate printing of non-conventional polymer nanocomposites (CNT- and graphene-based polybutylene terephthalate (PBT)) on a commercially available desktop 3D printer leading toward

  12. Dual function of the hemagglutinin H5 fused to chicken CD154 in a ...

    African Journals Online (AJOL)

    Dual function of the hemagglutinin H5 fused to chicken CD154 in a potential strategy of DIVA against avian influenza disease: preliminary study. AG Pose, ES Rodriguez, AC Mendez, JN Gomez, AV Redondo, ER Rodriguez, EMG Ramos, AA Gutierrez, MPR Molto, DG Roche, YS Ugalde, AM Lopez ...

  13. Angioplasty and stent placement - peripheral arteries - discharge

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000234.htm Angioplasty and stent placement - peripheral arteries - discharge To use the sharing ... peripheral artery). You may have also had a stent placed. To perform the procedure: Your doctor inserted ...

  14. Peripheral Ulcerative Keratitis

    Science.gov (United States)

    ... oval in shape. Diagnosis A doctor's evaluation Sometimes culture The diagnosis of peripheral ulcerative keratitis is suspected when the doctor sees the affected cornea in a person who also has a severe and/or long- ...

  15. Wireless sensor placement for structural monitoring using information-fusing firefly algorithm

    Science.gov (United States)

    Zhou, Guang-Dong; Yi, Ting-Hua; Xie, Mei-Xi; Li, Hong-Nan

    2017-10-01

    Wireless sensor networks (WSNs) are promising technology in structural health monitoring (SHM) applications for their low cost and high efficiency. The limited wireless sensors and restricted power resources in WSNs highlight the significance of optimal wireless sensor placement (OWSP) during designing SHM systems to enable the most useful information to be captured and to achieve the longest network lifetime. This paper presents a holistic approach, including an optimization criterion and a solution algorithm, for optimally deploying self-organizing multi-hop WSNs on large-scale structures. The combination of information effectiveness represented by the modal independence and the network performance specified by the network connectivity and network lifetime is first formulated to evaluate the performance of wireless sensor configurations. Then, an information-fusing firefly algorithm (IFFA) is developed to solve the OWSP problem. The step sizes drawn from a Lévy distribution are adopted to drive fireflies toward brighter individuals. Following the movement with Lévy flights, information about the contributions of wireless sensors to the objective function as carried by the fireflies is fused and applied to move inferior wireless sensors to better locations. The reliability of the proposed approach is verified via a numerical example on a long-span suspension bridge. The results demonstrate that the evaluation criterion provides a good performance metric of wireless sensor configurations, and the IFFA outperforms the simple discrete firefly algorithm.

  16. Hyperacute peripheral neuropathy is a predictor of oxaliplatin-induced persistent peripheral neuropathy.

    Science.gov (United States)

    Tanishima, Hiroyuki; Tominaga, Toshiji; Kimura, Masamichi; Maeda, Tsunehiro; Shirai, Yasutsugu; Horiuchi, Tetsuya

    2017-05-01

    Chronic peripheral neuropathy is a major adverse response to oxaliplatin-containing chemotherapy regimens, but there are no established risk factors pertaining to it. We investigated the efficacy of hyperacute peripheral neuropathy (HAPN) as a predictor of oxaliplatin-induced persistent peripheral neuropathy (PPN). Forty-seven cases of stage III colorectal cancer who received adjuvant chemotherapy with oxaliplatin after curative surgery between January 2010 and August 2014 were retrospectively reviewed. HAPN was defined as acute peripheral neuropathy (APN) occurring on day 1 (≤24 h after oxaliplatin infusion) of the first cycle. PPN was defined as neuropathy lasting >1 year after oxaliplatin discontinuation. The average total dose of oxaliplatin was 625.8 mg/m 2 , and the average relative dose intensity was 66.7%. Twenty-two of the 47 patients (46.8%) had PPN and 13 (27.7%) had HAPN. Male sex, treatment for neuropathy, HAPN, and APN were significantly more frequent in patients with PPN (p = 0.013, 0.02, <0.001, and 0.023, respectively). There was no significant difference in the total oxaliplatin dose between patients with and without PPN (p = 0.061). Multivariate analyses revealed total dose of oxaliplatin and HAPN as independent predictors of PPN [p = 0.015; odds ratio (OR) = 1.005, 95% confidence interval (CI), 1.001-1.009 and p = 0.001; OR = 75.307, 5.3-1070.123, respectively]. The total dose of oxaliplatin was relatively lower in patients with HAPN than that in those without HAPN in the PPN-positive group (not significant, p = 0.068). HAPN was found to be a predictor of oxaliplatin-induced PPN.

  17. Studi Koordinasi Fuse Dan Recloser Pada Jaringan Distribusi 20 Kv Yang Terhubung Dengan Distributed Generation (Studi Kasus: Penyulang PM. 6 Gardu Induk Pematangsiantar)

    OpenAIRE

    Pasaribu, Riko Jogi Petrus

    2016-01-01

    Penggunaan Distributed Generation pada jaringan distribusi dapat mengganggu koordinasi fuse dan recloser dikarenakan arus gangguan tidak hanya disuplai oleh gardu induk tetapi juga disuplai oleh Distributed Generation. Penelitian sebelumnya telah dilakukan terhadap keandalan koordinasi fuse dan recloser pada jaringan distribusi yang terhubung dengan Distributed Generation dimana penelitian tersebut menjelaskan bahwa terjadi perubahan kinerja dari koordinasi kedua perangkat ters...

  18. Studies of peripheral sensory nerves in paclitaxel-induced painful peripheral neuropathy: Evidence for mitochondrial dysfunction

    OpenAIRE

    Flatters, Sarah J.L.; Bennett, Gary J.

    2006-01-01

    Paclitaxel chemotherapy frequently induces neuropathic pain during and often persisting after therapy. The mechanisms responsible for this pain are unknown. Using a rat model of paclitaxel-induced painful peripheral neuropathy, we have performed studies to search for peripheral nerve pathology. Paclitaxel-induced mechano-allodynia and mechano-hyperalgesia were evident after a short delay, peaked at day 27 and finally resolved on day 155. Paclitaxel- and vehicle-treated rats were perfused on d...

  19. Ab initio modeling of fused silica, crystal quartz, and water Raman spectra

    Czech Academy of Sciences Publication Activity Database

    Dračínský, Martin; Benda, Ladislav; Bouř, Petr

    2011-01-01

    Roč. 512, č. 13 (2011), s. 54-59 ISSN 0009-2614 R&D Projects: GA ČR GAP208/11/0105; GA MŠk(CZ) LH11033 Grant - others:GA MŠk(CZ) 2B08021 Program:2B Institutional research plan: CEZ:AV0Z40550506 Keywords : fused silica * Raman spectroscopy * Car -Parrinello molecular dynamics Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 2.337, year: 2011

  20. Unipedal stance testing in the assessment of peripheral neuropathy.

    Science.gov (United States)

    Hurvitz, E A; Richardson, J K; Werner, R A

    2001-02-01

    To define further the relation between unipedal stance testing and peripheral neuropathy. Prospective cohort. Electroneuromyography laboratory of a Veterans Affairs medical center and a university hospital. Ninety-two patients referred for lower extremity electrodiagnostic studies. A standardized history and physical examination designed to detect peripheral neuropathy, 3 trials of unipedal stance, and electrodiagnostic studies. Peripheral neuropathy was identified by electrodiagnostic testing in 32%. These subjects had a significantly shorter (p unipedal stance time (15.7s, longest of 3 trials) than the patients without peripheral neuropathy (37.1s). Abnormal unipedal stance time (unipedal stance time had a negative predictive value of 90%. Abnormal unipedal stance time was associated with an increased risk of having peripheral neuropathy on univariate analysis (odds ratio = 8.8, 95% confidence interval = 2.5--31), and was the only significant predictor of peripheral neuropathy in the regression model. Aspects of the neurologic examination did not add to the regression model compared with abnormal unipedal stance time. Unipedal stance testing is useful in the clinical setting both to identify and to exclude the presence of peripheral neuropathy.

  1. Process and apparatus for extraction of gases produced during operation of a fused-salt nuclear reactor

    International Nuclear Information System (INIS)

    Blum, J.; Marie, J.

    1976-01-01

    The present invention relates to the field of fused-salt nuclear reactors and its object is the extraction of the gases produced in the course of operation of these reactors. The process according to the invention consists in placing into position a piece of material permeable for gases and impermeable for the used fused salts, for instance, a piece of graphite, in such a way that part of the surface of this piece is in contact with the circuit of the radioactive salts and another part connected to a gas suction device. The piece could also be scavenged in its mass by a flow of inert gas. Application is contemplated in reactors using a mixture of lithium fluoride, beryllium fluoride, and uranium and/or thorium fluoride. 10 claims, 2 drawing figures

  2. Proposal for the award of a contract, without competitive tendering, for the supply of radiation-tolerant anti-fuse FPGAs for the LHC

    CERN Document Server

    2004-01-01

    This document concerns the award of a contract, without competitive tendering, for the supply of 14 800 radiation-tolerant anti-fuse Field Programmable Gate Arrays (FPGAs) for the LHC. For the reasons explained in this document, the Finance Committee is invited to agree to the negotiation of a contract with MEMEC (CH), for the supply of 14 800 anti-fuse FPGAs for a total amount of 574 330 US dollars (654 900 Swiss francs), not subject to revision, with an option for up to 2960 additional anti-fuse FPGAs for an amount not exceeding 114 866 US dollars (130 980 Swiss francs) bringing the total amount to 689 196 US dollars (758 880 Swiss francs) not subject to revision. The amounts in Swiss francs have been calculated using the present rate of exchange.

  3. Clinical Evaluation of Fused/Ankylosed Hip with Severe Flexion Deformity after Conversion to Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Saroj Kumar Suwal

    2016-06-01

    Conclusions: THA is an effective treatment for ankylosed hip with severe flexion deformity although complications are noted more than routine hip arthroplasties. Keywords: ankylosed hip; fused hip; severe flexion deformity; total hip arthroplasty. | PubMed

  4. Lipid-lowering drugs (statins) and peripheral neuropathy.

    Science.gov (United States)

    Emad, Mohammadreza; Arjmand, Hosein; Farpour, Hamid Reza; Kardeh, Bahareh

    2018-03-01

    Peripheral neuropathy is a disorder with often unknown causes. Some drugs, including statins, are proposed to be among the causes of peripheral neuropathy. This study aimed at evaluating this condition by electrodiagnostic study among patients who had received statins. This case-control study was conducted in Shiraz, Iran in 2015, and included 39 patients aged 35-55 who had received statins for at least 6 months, and 39 healthy matched controls. Using electrodiagnosis, the sensory and motor wave features (amplitude, latency and nerve conduction velocity) of the peripheral nerves (Median, Ulnar, Tibial, Sural, and Peroneal) were evaluated among the subjects. Data were analyzed using SPSS software and pneuropathy, there were no significant differences in any of the definitions presented for peripheral neuropathy. However, the difference was close to significance for one definition [2 abnormalities in 2 nerves (p=0.055)]. Regarding mean values of the features, significant differences were observed in two features: amplitude of the peroneal motor nerve (p=0.048) and amplitude of the sural sensory nerve (p=0.036). Since statins are widely used, awareness regarding their side-effects would lead to better treatment. Even though no significant differences were found between the groups regarding the occurrence of peripheral neuropathy, there were significant differences in amplitudes of the sural sensory response and the peroneal motor response. This indicates the involvement of peripheral nerves. Therefore, we recommend that patients and physicians should be informed about the possible symptoms of this condition.

  5. Peripheral epithelial odontogenic tumor

    International Nuclear Information System (INIS)

    Carzoglio, J.; Tancredi, N.; Capurro, S.; Ravecca, T.; Scarrone, P.

    2006-01-01

    A new case of peripheral epithelial odontogenic tumor (Pindborg tumor) is reported. It is localized in the superior right gingival region, a less frequent site, and has the histopathological features previously reported. Immunochemical studies were performed, revealing a differential positive stain to cytokeratins in tumor cells deeply seated in the tumor mass, probably related to tumoral cell heterogeneity.Interestingly, in this particular case S-100 protein positive reactivity was also detected in arborescent cells intermingled with tumoral cells, resembling Langerhans cells. Even though referred in the literature in central Pindborg tumors, no references were found about their presence in peripheral tumors, like the one that is presented here

  6. Haemopoietic progenitor cells in human peripheral blood

    International Nuclear Information System (INIS)

    Zwaan, F.E.

    1980-01-01

    The purpose of the investigation reported is to purify haemopoietic progenitor cells from human peripheral blood using density gradient centrifugation in order to isolate a progenitor cell fraction without immunocompetent cells. The purification technique of peripheral blood flow colony forming unit culture (CFU-c) by means of density gradient centrifugation and a combined depletion of various rosettes is described. The results of several 'in vitro' characteristics of purified CFU-c suspensions and of the plasma clot diffusion chamber culture technique are presented. Irradiation studies revealed that for both human bone marrow and peripheral blood the CFU-c were less radioresistant than clusters. Elimination of monocytes (and granulocytes) from the test suspensions induced an alteration in radiosensitivity pararmeters. The results obtained with the different techniques are described by analysing peripheral progenitor cell activity in myeloproliferative disorders. (Auth.)

  7. Label-free photoacoustic microscopy of peripheral nerves

    Science.gov (United States)

    Matthews, Thomas Paul; Zhang, Chi; Yao, Da-Kang; Maslov, Konstantin; Wang, Lihong V.

    2014-01-01

    Peripheral neuropathy is a common neurological problem that affects millions of people worldwide. Diagnosis and treatment of this condition are often hindered by the difficulties in making objective, noninvasive measurements of nerve fibers. Photoacoustic microscopy (PAM) has the ability to obtain high resolution, specific images of peripheral nerves without exogenous contrast. We demonstrated the first proof-of-concept imaging of peripheral nerves using PAM. As validated by both standard histology and photoacoustic spectroscopy, the origin of photoacoustic signals is myelin, the primary source of lipids in the nerves. An extracted sciatic nerve sandwiched between two layers of chicken tissue was imaged by PAM to mimic the in vivo case. Ordered fibrous structures inside the nerve, caused by the bundles of myelin-coated axons, could be observed clearly. With further technical improvements, PAM can potentially be applied to monitor and diagnose peripheral neuropathies.

  8. Peripheral Neuropathy and Nerve Compression Syndromes in Burns.

    Science.gov (United States)

    Strong, Amy L; Agarwal, Shailesh; Cederna, Paul S; Levi, Benjamin

    2017-10-01

    Peripheral neuropathy and nerve compression syndromes lead to substantial morbidity following burn injury. Patients present with pain, paresthesias, or weakness along a specific nerve distribution or experience generalized peripheral neuropathy. The symptoms manifest at various times from within one week of hospitalization to many months after wound closure. Peripheral neuropathy may be caused by vascular occlusion of vasa nervorum, inflammation, neurotoxin production leading to apoptosis, and direct destruction of nerves from the burn injury. This article discusses the natural history, diagnosis, current treatments, and future directions for potential interventions for peripheral neuropathy and nerve compression syndromes related to burn injury. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Peripheral orbit model

    CERN Document Server

    Hara, Yasuo

    1975-01-01

    Peripheral orbit model, in which an incoming hadron is assumed to revolve in a peripheral orbit around a target hadron, is discussed. The non-diffractive parts of two-body reaction amplitudes of hadrons are expressed in terms of the radius, width an absorptivity of the orbit. The radius of the orbit is about 1 fm and the width of the orbit is determined by the range of the interaction between the hadrons. The model reproduces all available experimental data on differential cross-sections and polarizations of $K^{-}p\\to K^{-}p$ and $\\bar K^{\\circ}n$ reactions for all angles successfully. This contribution is not included in the proceedings since it will appear in Progress of Theoretical Physics Vol. 51 (1974) No 2. Any person interested in the subject may apply for reprints to the author.

  10. Case report of a patient with peripheral facial nerve palsy

    OpenAIRE

    Rysová, Jana

    2013-01-01

    Title of bachelor's thesis: Case report of a patient with peripheral facial nerve palsy Summary: Teoretical part of bachelor's thesis contains theoretical foundation of peripheral facial nerve palsy. Practical part of bachelor's thesis contains physiotherapeutic case report of patient with peripheral facial nerve palsy. Key words: peripheral facial nerve palsy, casuistry, rehabilitation

  11. Expedient synthesis of fused azepine derivatives using a sequential rhodium(II)-catalyzed cyclopropanation/1-aza-Cope rearrangement of dienyltriazoles.

    Science.gov (United States)

    Schultz, Erica E; Lindsay, Vincent N G; Sarpong, Richmond

    2014-09-08

    A general method for the formation of fused dihydroazepine derivatives from 1-sulfonyl-1,2,3-triazoles bearing a tethered diene is reported. The process involves an intramolecular cyclopropanation of an α-imino rhodium(II) carbenoid, leading to a transient 1-imino-2-vinylcyclopropane intermediate which rapidly undergoes a 1-aza-Cope rearrangement to generate fused dihydroazepine derivatives in moderate to excellent yields. The reaction proceeds with similar efficiency on gram scale. The use of catalyst-free conditions leads to the formation of a novel [4.4.0] bicyclic heterocycle. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Understanding error generation in fused deposition modeling

    International Nuclear Information System (INIS)

    Bochmann, Lennart; Transchel, Robert; Wegener, Konrad; Bayley, Cindy; Helu, Moneer; Dornfeld, David

    2015-01-01

    Additive manufacturing offers completely new possibilities for the manufacturing of parts. The advantages of flexibility and convenience of additive manufacturing have had a significant impact on many industries, and optimizing part quality is crucial for expanding its utilization. This research aims to determine the sources of imprecision in fused deposition modeling (FDM). Process errors in terms of surface quality, accuracy and precision are identified and quantified, and an error-budget approach is used to characterize errors of the machine tool. It was determined that accuracy and precision in the y direction (0.08–0.30 mm) are generally greater than in the x direction (0.12–0.62 mm) and the z direction (0.21–0.57 mm). Furthermore, accuracy and precision tend to decrease at increasing axis positions. The results of this work can be used to identify possible process improvements in the design and control of FDM technology. (paper)

  13. Peripheral involvement of the joint in seronegative spondylarthritis; Periphere Gelenkbeteiligung bei seronegativen Spondarthritiden

    Energy Technology Data Exchange (ETDEWEB)

    Lingg, G.; Soltesz, I. [Rheumazentrum Bad Kreuznach (Germany). Zentrales Roentgeninstitut

    1997-10-01

    The subjects of this contributions have been restricted to the peripheral manifestations of seronegative spondylarthrosis, for reasons of conciseness and clearness. The most frequent occurrences discussed are psoriasis arthritis and, a little bit less frequent, peripheral involvement of the joint in ancylosing spondylitis and Reiter syndrome, as well as enteropathic spondylarthrosis. (orig./AJ) [Deutsch] Als Thema dieser Veroeffentlichung wurden aus Gruenden der Kuerze und der Uebersichtlichkeit aber nur die peripheren Manifestationen der seronegativen Spondarthropathien gewaehlt. Hier wiederum haben wir es am haeufigsten mit der Psoriasisarthritis und etwas seltener mit der peripheren Gelenkbeteiligung bei der Bechterew`schen Erkrankung und der Reiter`schen Erkrankung sowie der enteropathischen Spondarthritiden zu tun. (orig./AJ)

  14. Imaging of the peripheral vascular system

    International Nuclear Information System (INIS)

    Gould, S.A.; Pond, G.D.; Pinsky, S.; Moss, G.S.; Srikantaswamy, S.; Ryo, U.Y.

    1984-01-01

    This book is limited neither to the peripheral vascular system nor to diagnostic imaging techniques. Its 18 chapters cover nonimaging blood-flow techniques (Doppler ultrasound, plethysmography) as well as noninvasive and invasive imaging techniques (ultrasound, computed tomography, radionuclide digital-subtraction angiography, and contrast angiography). These are applied not only to the peripheral vascular system but also to the aorta and vena cava

  15. N-annulated perylene fused porphyrins with enhanced near-IR absorption and emission

    KAUST Repository

    Jiao, Chongjun

    2010-09-17

    N-Annulated perylene fused porphyrins 1 and 2 were synthesized by oxidative dehydrogenation using a Sc(OTf)3/DDQ system. These newly synthesized hybrid molecules are highly soluble in organic solvents and exhibit remarkably intense near-IR absorption, as well as detectable photoluminescence quantum yields, all of which are comparable to or even exceed those of either meso-β doubly linked porphyrin dimer/trimer or bis/tri-N-annulated rylenes. © 2010 American Chemical Society.

  16. Fusing Simultaneous EEG and fMRI Using Functional and Anatomical Information

    DEFF Research Database (Denmark)

    Hansen, Sofie Therese; Winkler, Irene; Hansen, Lars Kai

    2015-01-01

    Simultaneously measuring electro physical and hemodynamic signals has become more accessible in the last years and the need for modeling techniques that can fuse the modalities is growing. In this work we augment a specific fusion method, the multimodal Source Power Co-modulation (mSPoC), to not ...... on cortex level to the EEG sensors. The augmented mSPoC is shown to outperform the original version in realistic simulations where the signal to noise ratio is low or where training epochs are scarce....

  17. Raman spectroscopic detection of peripheral nerves towards nerve-sparing surgery

    Science.gov (United States)

    Minamikawa, Takeo; Harada, Yoshinori; Takamatsu, Tetsuro

    2017-02-01

    The peripheral nervous system plays an important role in motility, sensory, and autonomic functions of the human body. Preservation of peripheral nerves in surgery, namely nerve-sparing surgery, is now promising technique to avoid functional deficits of the limbs and organs following surgery as an aspect of the improvement of quality of life of patients. Detection of peripheral nerves including myelinated and unmyelinated nerves is required for the nerve-sparing surgery; however, conventional nerve identification scheme is sometimes difficult to identify peripheral nerves due to similarity of shape and color to non-nerve tissues or its limited application to only motor peripheral nerves. To overcome these issues, we proposed a label-free detection technique of peripheral nerves by means of Raman spectroscopy. We found several fingerprints of peripheral myelinated and unmyelinated nerves by employing a modified principal component analysis of typical spectra including myelinated nerve, unmyelinated nerve, and adjacent tissues. We finally realized the sensitivity of 94.2% and the selectivity of 92.0% for peripheral nerves including myelinated and unmyelinated nerves against adjacent tissues. Although further development of an intraoperative Raman spectroscopy system is required for clinical use, our proposed approach will serve as a unique and powerful tool for peripheral nerve detection for nerve-sparing surgery in the future.

  18. [Atherectomy for peripheral arterial disease].

    Science.gov (United States)

    Londero, Louise Skovgaard; Høgh, Annette Langager; Lindholt, Jes Sanddal

    2015-04-13

    Symptomatic peripheral arterial disease is managed according to national and international guidelines and the number of vascular reconstructions performed each year has increased over the past decade mainly due to an increasing frequency of endovascular procedures. Atherectomy as an alternative to the established treatment of symptomatic peripheral arterial disease has recently been analysed in a Cochrane review. In Denmark, atherectomy is not performed and so far the evidence is poor as the method is not an alternative to the established treatment in this country.

  19. Chronic obstructive pulmonary disease and peripheral neuropathy

    Directory of Open Access Journals (Sweden)

    Gupta Prem

    2006-01-01

    Full Text Available Chronic obstructive pulmonary disease (COPD is the fourth leading cause of death world-wide and a further increase in the prevalence as well as mortality of the disease is predicted for coming decades. There is now an increased appreciation for the need to build awareness regarding COPD and to help the thousands of people who suffer from this disease and die prematurely from COPD or its associated complication(s. Peripheral neuropathy in COPD has received scanty attention despite the fact that very often clinicians come across COPD patients having clinical features suggestive of peripheral neuropathy. Electrophysiological tests like nerve conduction studies are required to distinguish between axonal and demyelinating type of disorder that cannot be analyzed by clinical examination alone. However, various studies addressing peripheral neuropathy in COPD carried out so far have included patients with COPD having markedly varying baseline characteristics like severe hypoxemia, elderly patients, those with long duration of illness, etc. that are not uniform across the studies and make it difficult to interpret the results to a consistent conclusion. Almost one-third of COPD patients have clinical evidence of peripheral neuropathy and two-thirds have electrophysiological abnormalities. Some patients with no clinical indication of peripheral neuropathy do have electrophysiological deficit suggestive of peripheral neuropathy. The more frequent presentation consists of a polyneuropathy that is subclinical or with predominantly sensory signs, and the neurophysiological and pathological features of predominantly axonal neuropathy. The presumed etiopathogenic factors are multiple: chronic hypoxia, tobacco smoke, alcoholism, malnutrition and adverse effects of certain drugs.

  20. Nerve conduction and excitability studies in peripheral nerve disorders

    DEFF Research Database (Denmark)

    Krarup, Christian; Moldovan, Mihai

    2009-01-01

    counterparts in the peripheral nervous system, in some instances without peripheral nervous system symptoms. Both hereditary and acquired demyelinating neuropathies have been studied and the effects on nerve pathophysiology have been compared with degeneration and regeneration of axons. SUMMARY: Excitability......PURPOSE OF REVIEW: The review is aimed at providing information about the role of nerve excitability studies in peripheral nerve disorders. It has been known for many years that the insight into peripheral nerve pathophysiology provided by conventional nerve conduction studies is limited. Nerve...... excitability studies are relatively novel but are acquiring an increasingly important role in the study of peripheral nerves. RECENT FINDINGS: By measuring responses in nerve that are related to nodal function (strength-duration time constant, rheobase and recovery cycle) and internodal function (threshold...

  1. Design and Analysis of Fused Deposition Modeling 3D Printer Nozzle for Color Mixing

    Directory of Open Access Journals (Sweden)

    Shanling Han

    2017-01-01

    Full Text Available Fused deposition modeling (FDM has been one of the most widely used rapid prototyping (RP technologies leading to the increase in market attention. Obviously it is desirable to print 3D objects; however, existing FDM printers are restricted to printing only monochrome objects because of the entry-level nozzle structure, and literature on the topic is also sparse. In this paper, the CAD model of the nozzle is established first by UG (Unigraphics NX software to show the structure of fused deposition modeling 3D printer nozzle for color mixing. Second, the flow channel model of the nozzle is extracted and simplified. Then, the CAD and finite element model are established by UG and ICEM CFD software, respectively, to prepare for the simulation. The flow field is simulated by Fluent software. The nozzle’s suitable temperature at different extrusion speeds is obtained, and the reason for the blockage at the intersection of the heating block is revealed. Finally, test verification of the nozzle is performed, which can produce mixed-color artifacts stably.

  2. Ionization of Local Interstellar Gas Based on STIS and FUSE spectra of Nearby Stars

    Science.gov (United States)

    Redfield, Seth; Linsky, J. L.

    2009-01-01

    The ultraviolet contains many resonance line transitions that are sensitive to a range of ionization stages of ions present in the local interstellar medium (LISM). We couple observations of high resolution ultraviolet spectrographs, STIS and GHRS on the Hubble Space Telescope (HST) and the Far-Ultraviolet Spectroscopic Explorer (FUSE) in order to make a comprehensive survey of the ionization structure of the local interstellar medium. In particular, we focus on the sight line toward G191-B2B, a nearby (69 pc) white dwarf. We present interstellar detections of highly ionized elements (e.g., SiIII, CIII, CIV, etc) and compare them directly to neutral or singly ionized LISM detections (e.g., SiII, CII, etc). The extensive observations of G191-B2B provides an opportunity for a broad study of ionization stages of several elements, while a survey of several sight lines provides a comprehensive look at the ionization structure of the LISM. We acknowledge support for this project through NASA FUSE Grant NNX06AD33G.

  3. Evolution of Oxygen Deficiency Center on Fused Silica Surface Irradiated by Ultraviolet Laser and Posttreatment

    Directory of Open Access Journals (Sweden)

    Hai-Bing Lü

    2014-01-01

    Full Text Available Evolution of oxygen deficiency centers (ODCs on a fused silica surface irradiated using a 355 nm ultraviolet (UV laser beam in both vacuum and atmospheric conditions was quantitatively studied using photoluminescence and X-ray photoelectron spectroscopy. When the fusedsilica surface was exposed to the UV laser in vacuum, the laser damage threshold was decreased whereas the concentration of the ODCs was increased. For the fuse silica operated under the high power lasers, creation of ODCs on their surface resulted from the UV laser irradiation, and this is more severe in a high vacuum. The laser fluence and/or laser intensity have significant effects on the increase of the ODCs concentration. The ODCs can be effectively repaired using postoxygen plasma treatment and UV laser irradiation in an excessive oxygen environment. Results also demonstrated that the “gain” and “loss” of oxygen at the silica surface is a reversible and dynamic process.

  4. Perylene anhydride fused porphyrins as near-infrared sensitizers for dye-sensitized solar cells

    KAUST Repository

    Jiao, Chongjun

    2011-07-15

    Two perylene anhydride fused porphyrins 1 and 2 have been synthesized and employed successfully in dye-sensitized solar cells (DSCs). Both compounds showed broad incident monochromatic photon-to-current conversion efficiency spectra covering the entire visible spectral region and even extending into the near-infrared (NIR) region up to 1000 nm, which is impressive for ruthenium-free dyes in DSCs. © 2011 American Chemical Society.

  5. Peripheral Nervous System Manifestations in Systemic Autoimmune Diseases

    OpenAIRE

    COJOCARU, Inimioara Mihaela; COJOCARU, Manole; SILOSI, Isabela; VRABIE, Camelia Doina

    2014-01-01

    The peripheral nervous system refers to parts of the nervous system outside the brain and spinal cord. Systemic autoimmune diseases can affect both the central and peripheral nervous systems in a myriad of ways and through a heterogeneous number of mechanisms leading to many different clinical manifestations. As a result, neurological complications of these disorders can result in significant morbidity and mortality. The most common complication of peripheral nervous system (PNS) involvement ...

  6. Passive Scalar Evolution in Peripheral Region

    OpenAIRE

    Lebedev, V. V.; Turitsyn, K. S.

    2003-01-01

    We consider evolution of a passive scalar (concentration of pollutants or temperature) in a chaotic (turbulent) flow. A universal asymptotic behavior of the passive scalar decay (homogenization) related to peripheral regions (near walls) is established. The passive scalar moments and its pair correlation function in the peripheral region are analyzed. A special case investigated in our paper is the passive scalar decay along a pipe.

  7. Fabrication of Through via Holes in Ultra-Thin Fused Silica Wafers for Microwave and Millimeter-Wave Applications

    Directory of Open Access Journals (Sweden)

    Xiao Li

    2018-03-01

    Full Text Available Through via holes in fused silica are a key infrastructure element of microwave and millimeter-wave circuits and 3D integration. In this work, etching through via holes in ultra-thin fused silica wafers using deep reactive-ion etching (DRIE and laser ablation was developed and analyzed. The experimental setup and process parameters for both methods are presented and compared. For DRIE, three types of mask materials including KMPR 1035 (Nippon Kayaku, Tokyo, Japan photoresist, amorphous silicon and chromium—with their corresponding optimized processing recipes—were tested, aiming at etching through a 100 μm fused silica wafer. From the experiments, we concluded that using chromium as the masking material is the best choice when using DRIE. However, we found that the laser ablation method with a laser pulse fluence of 2.89 J/cm2 and a pulse overlap of 91% has advantages over DRIE. The laser ablation method has a simpler process complexity, while offering a fair etching result. In particular, the sidewall profile angle is measured to be 75° to the bottom surface of the wafer, which is ideal for the subsequent metallization process. As a demonstration, a two-inch wafer with 624 via holes was processed using both technologies, and the laser ablation method showed better efficiency compared to DRIE.

  8. Imaging of the peripheral retina

    Directory of Open Access Journals (Sweden)

    Marcus Kernt

    2013-01-01

    Full Text Available The technical progress of the recent years has revolutionized imaging in ophthalmology. Scanning laser ophthalmoscopy (SLO, digital angiography, optical coherence tomography (OCT, and detection of fundus autofluorescence (FAF have fundamentally changed our understanding of numerous retinal and choroidal diseases. Besides the tremendous advances in macular diagnostics, there is more and more evidence that central pathologies are often directly linked to changes in the peripheral retina. This review provides a brief overview on current posterior segment imaging techniques with a special focus on the peripheral retina.

  9. Peripheral myelin protein 22 alters membrane architecture

    Science.gov (United States)

    Mittendorf, Kathleen F.; Marinko, Justin T.; Hampton, Cheri M.; Ke, Zunlong; Hadziselimovic, Arina; Schlebach, Jonathan P.; Law, Cheryl L.; Li, Jun; Wright, Elizabeth R.; Sanders, Charles R.; Ohi, Melanie D.

    2017-01-01

    Peripheral myelin protein 22 (PMP22) is highly expressed in myelinating Schwann cells of the peripheral nervous system. PMP22 genetic alterations cause the most common forms of Charcot-Marie-Tooth disease (CMTD), which is characterized by severe dysmyelination in the peripheral nerves. However, the functions of PMP22 in Schwann cell membranes remain unclear. We demonstrate that reconstitution of purified PMP22 into lipid vesicles results in the formation of compressed and cylindrically wrapped protein-lipid vesicles that share common organizational traits with compact myelin of peripheral nerves in vivo. The formation of these myelin-like assemblies depends on the lipid-to-PMP22 ratio, as well as on the PMP22 extracellular loops. Formation of the myelin-like assemblies is disrupted by a CMTD-causing mutation. This study provides both a biochemical assay for PMP22 function and evidence that PMP22 directly contributes to membrane organization in compact myelin. PMID:28695207

  10. Peripheral Artery Disease

    Science.gov (United States)

    ... pressure High blood cholesterol Coronary heart disease Stroke Metabolic syndrome Screening and Prevention Taking action to control your risk factors can help prevent or delay peripheral artery disease (P.A.D.) and its complications. Know your family history of health problems related to P.A. ...

  11. Total dose and dose-rate effects on start-up current in anti-fuse FPGA

    International Nuclear Information System (INIS)

    Wang, J.; Wong, W.; McCollum, J.; Cronquist, B.; Katz, R.; Kleyner, I.; Kleyner, F.

    1999-01-01

    Radiation enhanced start-up current (RESC) in an anti-fuse FPGA, A1280A, is thoroughly investigated and a comprehensive transistor-level mechanism is proposed. Low dose-rate testing, appropriate for civilian space applications, and annealing at room temperature shows RESC to be negligible for the lot of parts tested with a fixed power supply slew rate. (authors)

  12. Dual function of the hemagglutinin H5 fused to chicken CD154 in a ...

    African Journals Online (AJOL)

    Dual function of the hemagglutinin H5 fused to chicken CD154 in a potential strategy of DIVA against avian influenza disease: preliminary study. ... The PDF file you selected should load here if your Web browser has a PDF reader plug-in installed (for example, a recent version of Adobe Acrobat Reader). If you would like ...

  13. Incorporating TCNQ into thiophene-fused heptacene for n-channel field effect transistor

    KAUST Repository

    Ye, Qun

    2012-06-01

    Incorporation of electron-deficient tetracyanoquinodimethane (TCNQ) into electron-rich thiophene-fused heptacene was successfully achieved for the purpose of stabilizing longer acenes and generating new n-type organic semiconductors. The heptacene-TCNQ derivative 1 was found to have good stability and an expected electron transporting property. Electron mobility up to 0.01 cm 2 V -1 s -1 has been obtained for this novel material in solution processed organic field effect transistors. © 2012 American Chemical Society.

  14. Peripheral Osteoma of the Mandibular Notch: Report of a Case

    International Nuclear Information System (INIS)

    Iwai, Toshinori; Izumi, Toshiharu; Baba, Junichi; Maegawa, Jiro; Mitsudo, Kenji; Tohnai, Iwai

    2013-01-01

    Osteoma is a benign, slow-growing osteogenic tumor that sometimes arises from the craniomaxillofacial region, such as the sinus, temporal or jaw bones. Osteoma consists of compact or cancellous bone that may be peripheral, central or extraskeletal type. Peripheral osteoma arises from the periosteum and is commonly a unilateral, pedunculated mushroom-like mass. Peripheral osteoma of the mandible is relatively uncommon, and peripheral osteoma of the mandibular notch is extremely rare, although many cases arise from the mandibular body, angle, condyle, or coronoid process. We report here an unusual peripheral osteoma of the mandibular notch in a 78-year-old nonsyndromic female

  15. Using conceptual spaces to fuse knowledge from heterogeneous robot platforms

    Science.gov (United States)

    Kira, Zsolt

    2010-04-01

    As robots become more common, it becomes increasingly useful for many applications to use them in teams that sense the world in a distributed manner. In such situations, the robots or a central control center must communicate and fuse information received from multiple sources. A key challenge for this problem is perceptual heterogeneity, where the sensors, perceptual representations, and training instances used by the robots differ dramatically. In this paper, we use Gärdenfors' conceptual spaces, a geometric representation with strong roots in cognitive science and psychology, in order to represent the appearance of objects and show how the problem of heterogeneity can be intuitively explored by looking at the situation where multiple robots differ in their conceptual spaces at different levels. To bridge low-level sensory differences, we abstract raw sensory data into properties (such as color or texture categories), represented as Gaussian Mixture Models, and demonstrate that this facilitates both individual learning and the fusion of concepts between robots. Concepts (e.g. objects) are represented as a fuzzy mixture of these properties. We then treat the problem where the conceptual spaces of two robots differ and they only share a subset of these properties. In this case, we use joint interaction and statistical metrics to determine which properties are shared. Finally, we show how conceptual spaces can handle the combination of such missing properties when fusing concepts received from different robots. We demonstrate the fusion of information in real-robot experiments with a Mobile Robots Amigobot and Pioneer 2DX with significantly different cameras and (on one robot) a SICK lidar.ÿÿÿÿ

  16. Peripheral Primitive Neuroectodermal Tumor of the Stomach: A Case Report

    International Nuclear Information System (INIS)

    Park, Woon Ju; Cho, June Sik; Shin, Kyung Sook; Jeong, Hyung Yong; Noh; Seung Moo; Song, Kyu Sang

    2010-01-01

    Peripheral primitive neuroectodermal tumors (peripheral PNETs) are very rare and highly aggressive soft tissue malignancies originating from the neural crest. To the best of our knowledge, only a few cases of peripheral PNETs of the stomach have been reported in the literature. We report a case of large peripheral primitive neuroectodermal tumor of the stomach with MDCT findings in a 22-year-old man presenting epigastric pain and vomiting

  17. Peripheral T-Cell Lymphoma

    Science.gov (United States)

    ... Non-Hodgkin Lymphoma Peripheral T-Cell Lymphoma Primary Central Nervous System Lymphoma T-Cell Lymphoma Transformed Mycosis Fungoides Waldenstrom Macroglobulinemia Young Adult Lymphoma Overview Treatment Options Relapsed/Refractory Long-term ...

  18. Peripheral facial palsy in children.

    Science.gov (United States)

    Yılmaz, Unsal; Cubukçu, Duygu; Yılmaz, Tuba Sevim; Akıncı, Gülçin; Ozcan, Muazzez; Güzel, Orkide

    2014-11-01

    The aim of this study is to evaluate the types and clinical characteristics of peripheral facial palsy in children. The hospital charts of children diagnosed with peripheral facial palsy were reviewed retrospectively. A total of 81 children (42 female and 39 male) with a mean age of 9.2 ± 4.3 years were included in the study. Causes of facial palsy were 65 (80.2%) idiopathic (Bell palsy) facial palsy, 9 (11.1%) otitis media/mastoiditis, and tumor, trauma, congenital facial palsy, chickenpox, Melkersson-Rosenthal syndrome, enlarged lymph nodes, and familial Mediterranean fever (each 1; 1.2%). Five (6.1%) patients had recurrent attacks. In patients with Bell palsy, female/male and right/left ratios were 36/29 and 35/30, respectively. Of them, 31 (47.7%) had a history of preceding infection. The overall rate of complete recovery was 98.4%. A wide variety of disorders can present with peripheral facial palsy in children. Therefore, careful investigation and differential diagnosis is essential. © The Author(s) 2013.

  19. Peripheral doses from pediatric IMRT

    International Nuclear Information System (INIS)

    Klein, Eric E.; Maserang, Beth; Wood, Roy; Mansur, David

    2006-01-01

    Peripheral dose (PD) data exist for conventional fields (≥10 cm) and intensity-modulated radiotherapy (IMRT) delivery to standard adult-sized phantoms. Pediatric peripheral dose reports are limited to conventional therapy and are model based. Our goal was to ascertain whether data acquired from full phantom studies and/or pediatric models, with IMRT treatment times, could predict Organ at Risk (OAR) dose for pediatric IMRT. As monitor units (MUs) are greater for IMRT, it is expected IMRT PD will be higher; potentially compounded by decreased patient size (absorption). Baseline slab phantom peripheral dose measurements were conducted for very small field sizes (from 2 to 10 cm). Data were collected at distances ranging from 5 to 72 cm away from the field edges. Collimation was either with the collimating jaws or the multileaf collimator (MLC) oriented either perpendicular or along the peripheral dose measurement plane. For the clinical tests, five patients with intracranial or base of skull lesions were chosen. IMRT and conventional three-dimensional (3D) plans for the same patient/target/dose (180 cGy), were optimized without limitation to the number of fields or wedge use. Six MV, 120-leaf MLC Varian axial beams were used. A phantom mimicking a 3-year-old was configured per Center for Disease Control data. Micro (0.125 cc) and cylindrical (0.6 cc) ionization chambers were appropriated for the thyroid, breast, ovaries, and testes. The PD was recorded by electrometers set to the 10 -10 scale. Each system set was uniquely calibrated. For the slab phantom studies, close peripheral points were found to have a higher dose for low energy and larger field size and when MLC was not deployed. For points more distant from the field edge, the PD was higher for high-energy beams. MLC orientation was found to be inconsequential for the small fields tested. The thyroid dose was lower for IMRT delivery than that predicted for conventional (ratio of IMRT/cnventional ranged from

  20. FUSE SPECTROSCOPIC ANALYSIS OF THE SLOWEST SYMBIOTIC NOVA AG PEG DURING QUIESCENCE

    Science.gov (United States)

    Sion, Edward Michael; Godon, Patrick; Katynski, Marcus; Mikolajewska, Joanna

    2018-01-01

    We present a far ultraviolet spectroscopic analysis of the slowest known symbiotic nova AG Peg (MIII giant + hot white dwarf; P_orb = 818.4 days) which underwent a nova explosion in 1850 followed by a very slow decline that did not end until ~ 1996, marking the beginning of queiscence. Eight years of quiescence ended in June 2015, when AG Peg exhibited a Z And-type outburst with an optical amplitude of ~ 3 magnitudes. We have carried out accretion disk and WD photosphere synthetic spectral modeling of a FUSE spectrum (Froning et al. 2014) obtained on June 5.618, 2003 during the quiescence intervai ~ 12 years before the 2015 outburst. The spectrum is heavily affected by ISM absorption as well as strong broad emission lines. We de-reddened the FUSE fluxes with E(B-V) = 0.10 which is the maximum galactic reddening in the direction of AG Peg and took the distance of 800 pc (Kenyon et al. 1993) but used a range of white dwarf masses, surface temperatures and disk inclination angles. Our analysis also incororates archival HST FOS spectra obtained in 1996 at the onset of quiescence, 147 years after the 1850 nova explosion. The results of our analysis are presented and implications are discussed.This work is supported in part by NASA ADP grant NNX17AF36G to Villanova University.

  1. Synthetic Lipid (DOPG) Vesicles Accumulate in the Cell Plate Region But Do Not Fuse1

    NARCIS (Netherlands)

    Esseling-Ozdoba, A.; Vos, J.W.; Lammeren, van A.A.M.; Emons, A.M.C.

    2008-01-01

    Synthetic Lipid (DOPG) Vesicles Accumulate in the Cell Plate Region But Do Not Fuse1,[W],[OA] Agnieszka Esseling-Ozdoba2, Jan W. Vos, André A.M. van Lammeren and Anne Mie C. Emons* Laboratory of Plant Cell Biology, Department of Plant Sciences, Wageningen University, 6703¿BD Wageningen, The

  2. Fused Deposition Modeling 3D Printing for (Bio)analytical Device Fabrication : Procedures, Materials, and Applications

    NARCIS (Netherlands)

    Salentijn, Gert Ij; Oomen, Pieter E; Grajewski, Maciej; Verpoorte, Elisabeth

    2017-01-01

    In this work, the use of fused deposition modeling (FDM) in a (bio)analytical/lab-on-a-chip research laboratory is described. First, the specifications of this 3D printing method that are important for the fabrication of (micro)devices were characterized for a benchtop FDM 3D printer. These include

  3. Peripheral Protein Unfolding Drives Membrane Bending.

    Science.gov (United States)

    Siaw, Hew Ming Helen; Raghunath, Gokul; Dyer, R Brian

    2018-06-20

    Dynamic modulation of lipid membrane curvature can be achieved by a number of peripheral protein binding mechanisms such as hy-drophobic insertion of amphipathic helices and membrane scaffolding. Recently, an alternative mechanism was proposed in which crowding of peripherally bound proteins induces membrane curvature through steric pressure generated by lateral collisions. This effect was enhanced using intrinsically disordered proteins that possess high hydrodynamic radii, prompting us to explore whether membrane bending can be triggered by the folding-unfolding transition of surface-bound proteins. We utilized histidine-tagged human serum albumin bound to Ni-NTA-DGS containing liposomes as our model system to test this hypothesis. We found that reduction of the disulfide bonds in the protein resulted in unfolding of HSA, which subsequently led to membrane tubule formation. The frequency of tubule formation was found to be significantly higher when the proteins were unfolded while being localized to a phase-separated domain as opposed to randomly distributed in fluid phase liposomes, indicating that the steric pressure generated from protein unfolding is directly responsible for membrane deformation. Our results are critical for the design of peripheral membrane protein-immobilization strategies and open new avenues for exploring mechanisms of membrane bending driven by conformational changes of peripheral membrane proteins.

  4. Noonan syndrome: crossed fused ectopic kidneys and focal segmental glomerulosclerosis-a rare association.

    Science.gov (United States)

    Gupta, Ankur; Khaira, Ambar; Lal, Charanjit; Mahajan, Sandeep; Tiwari, Suresh C

    2009-10-01

    Noonan syndrome is characterised by short stature, typical facial dysmorphology and congenital heart defects. Urogenital abnormalities are reported in 10% of the cases. We present a 14-year-old girl with characteristic features of Noonan syndrome and nephrotic-range proteinuria. She had crossed fused ectopic kidneys. Renal biopsy showed focal segmental glomerulosclerosis. Oral steroids were instituted and she responded well. The case highlights this novel renal presentation of Noonan syndrome.

  5. 21 CFR 882.5870 - Implanted peripheral nerve stimulator for pain relief.

    Science.gov (United States)

    2010-04-01

    ....5870 Implanted peripheral nerve stimulator for pain relief. (a) Identification. An implanted peripheral nerve stimulator for pain relief is a device that is used to stimulate electrically a peripheral nerve... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Implanted peripheral nerve stimulator for pain...

  6. Peripheral dose outside applicators in electron beams

    International Nuclear Information System (INIS)

    Chow, James C L; Grigorov, Grigor N

    2006-01-01

    The peripheral dose outside the applicators in electron beams was studied using a Varian 21 EX linear accelerator. To measure the peripheral dose profiles and point doses for the applicator, a solid water phantom was used with calibrated Kodak TL films. Peak dose spot was observed in the 4 MeV beam outside the applicator. The peripheral dose peak was very small in the 6 MeV beam and was ignorable at higher energies. Using the 10 x 10 cm 2 cutout and applicator, the dose peak for the 4 MeV beam was about 12 cm away from the field central beam axis (CAX) and the peripheral dose profiles did not change with depths measured at 0.2, 0.5 and 1 cm. The peripheral doses and profiles were further measured by varying the angle of obliquity, cutout and applicator size for the 4 MeV beam. The local peak dose was increased with about 3% per degree angle of obliquity, and was about 1% of the prescribed dose (angle of obliquity equals zero) at 1 cm depth in the phantom using the 10 x 10 cm 2 cutout and applicator. The peak dose position was also shifted 7 mm towards the CAX when the angle of obliquity was increased from 0 to 15 deg. (note)

  7. Intraoperative digital angiography: Peripheral vascular applications

    International Nuclear Information System (INIS)

    Bell, K.; Reifsteck, J.E.; Binet, E.F.; Fleisher, H.J.

    1986-01-01

    Intraoperative digital angiography is the procedure of choice for the peripheral vascular surgeon who wishes to evaluate his results before terminating anesthesia. Two operating suites at the John L. McClellan Memorial Veterans Hospital are equipped with permanent ceiling-mounted Philips C-arm fluoroscopes and share an ADAC 4100 digital angiographic system. In the last 18 months, 40 peripheral vascular intraoperative digital angiographic procedures have been performed, in all but two cases using direct arterial puncture. In 65% of cases, the intraoperative study showed no significant abnormality. In 12.5%, minor abnormalities not requiring reoperation were seen. In 22.5% of cases, the intraoperative digital angiogram revealed a significant abnormality requiring immediate operative revision. None of the patients who underwent reoperation experienced postoperative sequelae. Intraoperative digital angiography is useful in identifying complications of peripheral vascular operations

  8. Peripheral nerve conduits: technology update

    Directory of Open Access Journals (Sweden)

    Arslantunali D

    2014-12-01

    Full Text Available D Arslantunali,1–3,* T Dursun,1,2,* D Yucel,1,4,5 N Hasirci,1,2,6 V Hasirci,1,2,7 1BIOMATEN, Center of Excellence in Biomaterials and Tissue Engineering, Middle East Technical University (METU, Ankara, Turkey; 2Department of Biotechnology, METU, Ankara, Turkey; 3Department of Bioengineering, Gumushane University, Gumushane, Turkey; 4Faculty of Engineering, Department of Medical Engineering, Acibadem University, Istanbul, Turkey; 5School of Medicine, Department of Histology and Embryology, Acibadem University, Istanbul, Turkey; 6Department of Chemistry, Faculty of Arts and Sciences, METU, Ankara, Turkey; 7Department of Biological Sciences, Faculty of Arts and Sciences, METU, Ankara, Turkey *These authors have contributed equally to this work Abstract: Peripheral nerve injury is a worldwide clinical problem which could lead to loss of neuronal communication along sensory and motor nerves between the central nervous system (CNS and the peripheral organs and impairs the quality of life of a patient. The primary requirement for the treatment of complete lesions is a tension-free, end-to-end repair. When end-to-end repair is not possible, peripheral nerve grafts or nerve conduits are used. The limited availability of autografts, and drawbacks of the allografts and xenografts like immunological reactions, forced the researchers to investigate and develop alternative approaches, mainly nerve conduits. In this review, recent information on the various types of conduit materials (made of biological and synthetic polymers and designs (tubular, fibrous, and matrix type are being presented. Keywords: peripheral nerve injury, natural biomaterials, synthetic biomaterials

  9. Management of peripheral facial nerve palsy

    OpenAIRE

    Finsterer, Josef

    2008-01-01

    Peripheral facial nerve palsy (FNP) may (secondary FNP) or may not have a detectable cause (Bell?s palsy). Three quarters of peripheral FNP are primary and one quarter secondary. The most prevalent causes of secondary FNP are systemic viral infections, trauma, surgery, diabetes, local infections, tumor, immunological disorders, or drugs. The diagnosis of FNP relies upon the presence of typical symptoms and signs, blood chemical investigations, cerebro-spinal-fluid-investigations, X-ray of the...

  10. Improvement of Surface Finish by Multiple Piezoelectric Transducers in Fused Deposition Modelling

    OpenAIRE

    A. S. Mohamed; S. Maidin; S. B. Mohamed; M. K. Muhamad; J.H. U. Wong; W. F. A. Romlee

    2016-01-01

    Additive Manufacturing (AM) which embrace as a new range technology of creating and producing end user parts in term of adding material layer by layer to create solid object from 3D CAD data. AM in particular Fused Deposition Modelling (FDM) used (ABS) thermoplastic have shown the most popular among the industry as its technology can print complex geometrical part without human intervention and tools. However, FDM fierce enemy whereas the common problem of stair-stepping, which means that sea...

  11. Normal and sonographic anatomy of selected peripheral nerves. Part II: Peripheral nerves of the upper limb

    Directory of Open Access Journals (Sweden)

    Berta Kowalska

    2012-06-01

    Full Text Available The ultrasonographic examination is frequently used for imaging peripheral nerves. It serves to supplement the physical examination, electromyography, and magnetic resonance imaging. As in the case of other USG imaging studies, the examination of peripheral nerves is non-invasive, well-tolerated by patients, and relatively inexpensive. Part I of this article series described in detail the characteristic USG picture of peripheral nerves and the proper examination technique, following the example of the median nerve. This nerve is among the most often examined peripheral nerves of the upper limb. This part presents describes the normal anatomy and ultrasound picture of the remaining large nerve branches in the upper extremity and neck – the spinal accessory nerve, the brachial plexus, the suprascapular, axillary, musculocutaneous, radial and ulnar nerves. Their normal anatomy and ultrasonographic appearance have been described, including the division into individual branches. For each of them, specific reference points have been presented, to facilitate the location of the set trunk and its further monitoring. Sites for the application of the ultrasonographic probe at each reference point have been indicated. In the case of the ulnar nerve, the dynamic component of the examination was emphasized. The text is illustrated with images of probe positioning, diagrams of the normal course of the nerves as well as a series of ultrasonographic pictures of normal nerves of the upper limb. This article aims to serve as a guide in the ultrasound examination of the peripheral nerves of the upper extremity. It should be remembered that a thorough knowledge of the area’s topographic anatomy is required for this type of examination.

  12. Peripheral Atherectomy: Applications and Techniques.

    Science.gov (United States)

    Mittleider, Derek; Russell, Erich

    2016-06-01

    Peripheral atherectomy is a class of procedures that is rapidly increasing in volume. Multiple classes of devices exist, and newer variants are added to the market annually. The devices see wide application for de novo lesions, in-stent restenosis, and adjunctive therapy for drug-coated balloons. The body of evidence supporting atherectomy is less robust than for many other peripheral therapies. The frequency and severity of complications from atherectomy can be significant compared with angioplasty and stenting, and familiarity with preventative and bailout techniques is essential for the interventionalist. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Redox shuttles having an aromatic ring fused to a 1,1,4,4-tetrasubstituted cyclohexane ring

    Science.gov (United States)

    Weng, Wei; Zhang, Zhengcheng; Amine, Khalil

    2015-12-01

    An electrolyte includes an alkali metal salt; an aprotic solvent; and a redox shuttle additive including an aromatic compound having at least one aromatic ring fused with at least one non-aromatic ring, the aromatic ring having two or more oxygen or phosphorus-containing substituents.

  14. Imaging of a glioma using peripheral benzodiazepine receptor ligands

    Energy Technology Data Exchange (ETDEWEB)

    Starosta-Rubinstein, S.; Ciliax, B.J.; Penney, J.B.; McKeever, P.; Young, A.B.

    1987-02-01

    Two types of benzodiazepine receptors have been demonstrated in mammalian tissues, one which is localized on neuronal elements in brain and the other, on glial cells and in peripheral tissues such as kidney. In vivo administration of /sup 3/H-labeled PK 11195 (1-(2-chlorophenyl-N-methyl-N-(1-methylpropyl)-3-isoquinoline carboxamide) or (/sup 3/H)flunitrazepam with 5 mg of clonazepam per kg to rats with intracranial C6 gliomas resulted in high levels of tritiated-drug binding to the tumor as shown by quantitative autoradiography. Pharmacological studies indicated that the bound drugs labeled the peripheral benzodiazepine binding site. Binding to the peripheral benzodiazepine site was confirmed primarily to malignant cells with little binding to adjacent normal brain tissue or to necrotic tissue. Tumor cell binding was completely inhibited by preadministration of the peripheral benzodiazepine blocking agent PK 11195 at 5 mg/kg. The centrally selective benzodiazepine ligand clonazepam had no effect on PK 11195 binding to the tumor cells. When binding to other tumor cell lines grown in nude mice and nude athymic rats was evaluated, little or no peripheral benzodiazepine binding was detected on human pheochromocytoma (RN1) and neuroblastoma (SK-N-MC, SK-N-SH) tumor cells, respectively. However, high densities of peripheral benzodiazepine binding sites were observed on tumors derived from a human glioma cell line (ATCC HTB 14, U-87 MG). The presence of high concentrations of specific peripheral benzodiazepine receptors on glial tumors suggests that human primary central nervous system tumors could be imaged and diagnosed using peripheral benzodiazepine ligands labeled with positron- or gamma-emitting isotopes.

  15. Prospective surveillance of phlebitis associated with peripheral intravenous catheters.

    Science.gov (United States)

    Malach, Tal; Jerassy, Ziona; Rudensky, Bernard; Schlesinger, Yechiel; Broide, Etty; Olsha, Oded; Yinnon, Amos M; Raveh, David

    2006-06-01

    Guidelines have been published for prevention of phlebitis associated with peripheral intravenous catheters (IVC), but this complication continues to occur. We sought to determine the rate of phlebitis associated with peripheral IVCs to identify predictors for phlebitis and to isolate pathogenic bacteria from phlebitic catheter tips. Nine-point prevalence studies were conducted during the years 1996-2003 of all hospitalized patients with a peripheral IVC. During the last 3 surveys, conducted in 2003, phlebitic lines were removed, and, for each line, 1 to 2 nonphlebitic lines, in place for 48 to 72 hours, were removed and cultured as controls. In between these surveys, findings and guidelines for improvement were distributed to the staff. During these surveys, 40% +/- 8% of hospitalized patients had a peripheral IVC. The rate of peripheral IVC-associated phlebitis decreased from 12.7% (20/157) in 1998 to 2.6% (5/189) in 2003 (P phlebitis included pain (P phlebitis associated with peripheral intravenous catheters decreased significantly throughout the study period. The identification of predictors for phlebitis and the dissemination of this information in an educational drive may have contributed to this improvement.

  16. Fused cerebral organoids model interactions between brain regions.

    Science.gov (United States)

    Bagley, Joshua A; Reumann, Daniel; Bian, Shan; Lévi-Strauss, Julie; Knoblich, Juergen A

    2017-07-01

    Human brain development involves complex interactions between different regions, including long-distance neuronal migration or formation of major axonal tracts. Different brain regions can be cultured in vitro within 3D cerebral organoids, but the random arrangement of regional identities limits the reliable analysis of complex phenotypes. Here, we describe a coculture method combining brain regions of choice within one organoid tissue. By fusing organoids of dorsal and ventral forebrain identities, we generate a dorsal-ventral axis. Using fluorescent reporters, we demonstrate CXCR4-dependent GABAergic interneuron migration from ventral to dorsal forebrain and describe methodology for time-lapse imaging of human interneuron migration. Our results demonstrate that cerebral organoid fusion cultures can model complex interactions between different brain regions. Combined with reprogramming technology, fusions should offer researchers the possibility to analyze complex neurodevelopmental defects using cells from neurological disease patients and to test potential therapeutic compounds.

  17. Unified design of sinusoidal-groove fused-silica grating.

    Science.gov (United States)

    Feng, Jijun; Zhou, Changhe; Cao, Hongchao; Lu, Peng

    2010-10-20

    A general design rule of deep-etched subwavelength sinusoidal-groove fused-silica grating as a highly efficient polarization-independent or polarization-selective device is studied based on the simplified modal method, which shows that the device structure depends little on the incident wavelength, but mainly on the ratio of groove depth to incident wavelength and the ratio of wavelength to grating period. These two ratios could be used as the design guidelines for wavelength-independent structure from deep ultraviolet to far infrared. The optimized grating profile with a different function as a polarizing beam splitter, a polarization-independent two-port beam splitter, or a polarization-independent grating with high efficiency of -1st order is obtained at a wavelength of 1064 nm, and verified by using the rigorous coupled-wave analysis. The performance of the sinusoidal grating is better than a conventional rectangular one, which could be useful for practical applications.

  18. Fused Smart Sensor Network for Multi-Axis Forward Kinematics Estimation in Industrial Robots

    Directory of Open Access Journals (Sweden)

    Rene de Jesus Romero-Troncoso

    2011-04-01

    Full Text Available Flexible manipulator robots have a wide industrial application. Robot performance requires sensing its position and orientation adequately, known as forward kinematics. Commercially available, motion controllers use high-resolution optical encoders to sense the position of each joint which cannot detect some mechanical deformations that decrease the accuracy of the robot position and orientation. To overcome those problems, several sensor fusion methods have been proposed but at expenses of high-computational load, which avoids the online measurement of the joint’s angular position and the online forward kinematics estimation. The contribution of this work is to propose a fused smart sensor network to estimate the forward kinematics of an industrial robot. The developed smart processor uses Kalman filters to filter and to fuse the information of the sensor network. Two primary sensors are used: an optical encoder, and a 3-axis accelerometer. In order to obtain the position and orientation of each joint online a field-programmable gate array (FPGA is used in the hardware implementation taking advantage of the parallel computation capabilities and reconfigurability of this device. With the aim of evaluating the smart sensor network performance, three real-operation-oriented paths are executed and monitored in a 6-degree of freedom robot.

  19. Fused smart sensor network for multi-axis forward kinematics estimation in industrial robots.

    Science.gov (United States)

    Rodriguez-Donate, Carlos; Osornio-Rios, Roque Alfredo; Rivera-Guillen, Jesus Rooney; Romero-Troncoso, Rene de Jesus

    2011-01-01

    Flexible manipulator robots have a wide industrial application. Robot performance requires sensing its position and orientation adequately, known as forward kinematics. Commercially available, motion controllers use high-resolution optical encoders to sense the position of each joint which cannot detect some mechanical deformations that decrease the accuracy of the robot position and orientation. To overcome those problems, several sensor fusion methods have been proposed but at expenses of high-computational load, which avoids the online measurement of the joint's angular position and the online forward kinematics estimation. The contribution of this work is to propose a fused smart sensor network to estimate the forward kinematics of an industrial robot. The developed smart processor uses Kalman filters to filter and to fuse the information of the sensor network. Two primary sensors are used: an optical encoder, and a 3-axis accelerometer. In order to obtain the position and orientation of each joint online a field-programmable gate array (FPGA) is used in the hardware implementation taking advantage of the parallel computation capabilities and reconfigurability of this device. With the aim of evaluating the smart sensor network performance, three real-operation-oriented paths are executed and monitored in a 6-degree of freedom robot.

  20. Peripheral ossifying fibroma of oral cavity: histopathologic differential diagnoses.

    Science.gov (United States)

    Shamim, Thorakkal

    2012-01-01

    Peripheral ossifying fibroma is a benign neoplasm that usuallydevelops from gingiva, presenting as an exophytic smooth surfaced pink or red nodular mass that is sessile or is less frequently seen on a pedicle. From the Indian perspective, it is usually noticed in 5th-6th decades of life with female predilection. Microscopically, the tumour shows stratified squamous epithelium and highly cellular fibrous stroma, sparse endothelial proliferation with fibroblasts and dystrophic calcifications. It has to be differentiated histopathologically from pyogenic granuloma, fibroma, peripheral giant cell granuloma, peripheral odontogenic fibroma and fibrous hyperplasia. A case of peripheral ossifying fibroma of maxillary gingiva in a 55-year-old Indian woman is reported.

  1. MRI features of tuberculosis of peripheral joints

    Energy Technology Data Exchange (ETDEWEB)

    Sawlani, V.; Chandra, T.; Mishra, R.N.; Aggarwal, A.; Jain, U.K.; Gujral, R.B. E-mail: gujralrb@sgpgi.ac.in

    2003-10-01

    The aim of this article is to present the magnetic resonance imaging (MRI) features of peripheral tubercular arthritis. The clinical presentation of peripheral tubercular arthritis is variable and simulates other chronic inflammatory arthritic disorders. MRI is a highly sensitive technique which demonstrates fine anatomical details and identifies the early changes of arthritis, which are not visible on radiographs. The MRI features of tubercular arthritis include synovitis, effusion, central and peripheral erosions, active and chronic pannus, abscess, bone chips and hypo-intense synovium. These imaging features in an appropriate clinical setting may help in the diagnosis of tubercular arthritis. Early diagnosis and treatment can effectively eliminate the long-term morbidity of joints affected by tuberculosis.

  2. MRI features of tuberculosis of peripheral joints

    International Nuclear Information System (INIS)

    Sawlani, V.; Chandra, T.; Mishra, R.N.; Aggarwal, A.; Jain, U.K.; Gujral, R.B.

    2003-01-01

    The aim of this article is to present the magnetic resonance imaging (MRI) features of peripheral tubercular arthritis. The clinical presentation of peripheral tubercular arthritis is variable and simulates other chronic inflammatory arthritic disorders. MRI is a highly sensitive technique which demonstrates fine anatomical details and identifies the early changes of arthritis, which are not visible on radiographs. The MRI features of tubercular arthritis include synovitis, effusion, central and peripheral erosions, active and chronic pannus, abscess, bone chips and hypo-intense synovium. These imaging features in an appropriate clinical setting may help in the diagnosis of tubercular arthritis. Early diagnosis and treatment can effectively eliminate the long-term morbidity of joints affected by tuberculosis

  3. Contrast-enhanced peripheral MRA. Technique and contrast agents

    International Nuclear Information System (INIS)

    Nielsen, Yousef W.; Thomsen, Henrik S.

    2012-01-01

    In the last decade contrast-enhanced magnetic resonance angiography (CE-MRA) has gained wide acceptance as a valuable tool in the diagnostic work-up of patients with peripheral arterial disease. This review presents current concepts in peripheral CE-MRA with emphasis on MRI technique and contrast agents. Peripheral CE-MRA is defined as an MR angiogram of the arteries from the aortic bifurcation to the feet. Advantages of CE-MRA include minimal invasiveness and lack of ionizing radiation. The basic technique employed for peripheral CE-MRA is the bolus-chase method. With this method a paramagnetic MRI contrast agent is injected intravenously and T1-weighted images are acquired in the subsequent arterial first-pass phase. In order to achieve high quality MR angiograms without interfering venous contamination or artifacts, a number of factors need to be taken into account. This includes magnetic field strength of the MRI system, receiver coil configuration, use of parallel imaging, contrast bolus timing technique, and k-space filling strategies. Furthermore, it is possible to optimize peripheral CE-MRA using venous compression techniques, hybrid scan protocols, time-resolved imaging, and steady-state MRA. Gadolinium(Gd)-based contrast agents are used for CE-MRA of the peripheral arteries. Extracellular Gd agents have a pharmacokinetic profile similar to iodinated contrast media. Accordingly, these agents are employed for first-pass MRA. Blood-pool Gd-based agents are characterized by prolonged intravascular stay, due to macromolecular structure or protein binding. These agents can be used for first-pass, as well as steady-state MRA. Some Gd-based contrast agents with low thermodynamic stability have been linked to development of nephrogenic systemic fibrosis in patients with severe renal insufficiency. Using optimized technique and a stable MRI contrast agent, peripheral CE-MRA is a safe procedure with diagnostic accuracy close to that of conventional catheter X

  4. Associations between peripheral vertigo and gastroesophageal reflux disease.

    Science.gov (United States)

    Viliušytė, Edita; Macaitytė, Raminta; Vaitkus, Antanas; Rastenytė, Daiva

    2015-09-01

    We hypothesize that peripheral vertigo is associated with gastroesophageal reflux disease (GERD). Two mechanisms could be considered – gastric acids may directly irritate the respiratory mucosa and cause inflammation, or Helicobacter pylori (H. pylori) could be present and cause local infection. Reflux material (Hydrochloric acid (HCl) and pepsin) could get into the middle ear via Eustachian tube and affect osseous structures directly. Disturbance of ossicles could cause tinnitus, which is more common for peripheral vertigo. H. pylori could also get in the esophagus and in the upper respiratory tract via gastroesophageal reflux, and could cause tympanosclerosis and fixation of ossicles. In our study group, 120 of 153 (78.4%) patients had gastroesophageal reflux disease (GERD). Diagnostic tests of H. pylori (rapid urease test or blood antibody test) were performed for 96 of 120 (80%) patients with GERD and were found positive for 32 of 96 (33.3%) patients. Peripheral vertigo was present in 93 of 120 (77.6%) patients with GERD compared to 33 of 126 (26%) patients without GERD (χ(2)=9.016, p=0.003). H. pylori and peripheral vertigo coexisted in 26 of 126 patients (20.6%) (OR 1.36; 95% CI 0.49-3.74, p=0.55). Our study demonstrated statistically significant association between peripheral vertigo and GERD but not between peripheral vertigo and H. pylori. Further more extensive investigations are needed in order to explore our hypothesis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Imaging the spectral reflectance properties of bipolar radiofrequency-fused bowel tissue

    Science.gov (United States)

    Clancy, Neil T.; Arya, Shobhit; Stoyanov, Danail; Du, Xiaofei; Hanna, George B.; Elson, Daniel S.

    2015-07-01

    Delivery of radiofrequency (RF) electrical energy is used during surgery to heat and seal tissue, such as vessels, allowing resection without blood loss. Recent work has suggested that this approach may be extended to allow surgical attachment of larger tissue segments for applications such as bowel anastomosis. In a large series of porcine surgical procedures bipolar RF energy was used to resect and re-seal the small bowel in vivo with a commercial tissue fusion device (Ligasure; Covidien PLC, USA). The tissue was then imaged with a multispectral imaging laparoscope to obtain a spectral datacube comprising both fused and healthy tissue. Maps of blood volume, oxygen saturation and scattering power were derived from the measured reflectance spectra using an optimised light-tissue interaction model. A 60% increase in reflectance of visible light (460-700 nm) was observed after fusion, with the tissue taking on a white appearance. Despite this the distinctive shape of the haemoglobin absorption spectrum was still noticeable in the 460-600 nm wavelength range. Scattering power increased in the fused region in comparison to normal serosa, while blood volume and oxygen saturation decreased. Observed fusion-induced changes in the reflectance spectrum are consistent with the biophysical changes induced through tissue denaturation and increased collagen cross-linking. The multispectral imager allows mapping of the spatial extent of these changes and classification of the zone of damaged tissue. Further analysis of the spectral data in parallel with histopathological examination of excised specimens will allow correlation of the optical property changes with microscopic alterations in tissue structure.

  6. Peripheral Neuropathy: A Practical Approach to Diagnosis and Symptom Management.

    Science.gov (United States)

    Watson, James C; Dyck, P James B

    2015-07-01

    Peripheral neuropathy is one of the most prevalent neurologic conditions encountered by physicians of all specialties. Physicians are faced with 3 distinct challenges in caring for patients with peripheral neuropathy: (1) how to efficiently and effectively screen (in less than 2 minutes) an asymptomatic patient for peripheral neuropathy when they have a disorder in which peripheral neuropathy is highly prevalent (eg, diabetes mellitus), (2) how to clinically stratify patients presenting with symptoms of neuropathy to determine who would benefit from specialty consultation and what testing is appropriate for those who do not need consultation, and (3) how to treat the symptoms of painful peripheral neuropathy. In this concise review, we address these 3 common clinical scenarios. Easily defined clinical patterns of involvement are used to identify patients in need of neurologic consultation, the yield of laboratory and other diagnostic testing is reviewed for the evaluation of length-dependent, sensorimotor peripheral neuropathies (the most common form of neuropathy), and an algorithmic approach with dosing recommendations is provided for the treatment of neuropathic pain associated with peripheral neuropathy. Copyright © 2015 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  7. Diffuse Prior Monotonic Likelihood Ratio Test for Evaluation of Fused Image Quality Measures

    Science.gov (United States)

    2011-02-01

    pathological case 3As discussed in [33], any pmf of over can be generated by choosing a specific pdf to generate . WEI et al.: DIFFUSE PRIOR...fused via six different algorithms: 1) contrast pyramid A (CONA), 2) contrast pyramid B (CONB) [34], 3) dis- crete wavelet transform (DWTT) [1], [35...36] 4) color discrete wavelet transform (CDWT), 5) color averaging (CLAV), and 6) color multiscale transform (CLMT) [37]. The first three al

  8. Phenological monitoring of Acadia National Park using Landsat, MODIS and VIIRS observations and fused data

    Science.gov (United States)

    Liu, Y.; McDonough MacKenzie, C.; Primack, R.; Zhang, X.; Schaaf, C.; Sun, Q.; Wang, Z.

    2015-12-01

    Monitoring phenology with remotely sensed data has become standard practice in large-plot agriculture but remains an area of research in complex terrain. Landsat data (30m) provides a more appropriate spatial resolution to describe such regions but may only capture a few cloud-free images over a growing period. Daily data from the MODerate resolution Imaging Spectroradiometer(MODIS) and Visible Infrared Imaging Radiometer Suite(VIIRS) offer better temporal acquisitions but at coarse spatial resolutions of 250m to 1km. Thus fused data sets are being employed to provide the temporal and spatial resolutions necessary to accurately monitor vegetation phenology. This study focused on Acadia National Park, Maine, attempts to compare green-up from remote sensing and ground observations over varying topography. Three north-south field transects were established in 2013 on parallel mountains. Along these transects, researchers record the leaf out and flowering phenology for thirty plant species biweekly. These in situ spring phenological observations are compared with the dates detected by Landsat 7, Landsat 8, MODIS, and VIIRS observations, both separately and as fused data, to explore the ability of remotely sensed data to capture the subtle variations due to elevation. Daily Nadir BRDF Adjusted Reflectances(NBAR) from MODIS and VIIRS are fused with Landsat imagery to simulate 30m daily data via the Enhanced Spatial and Temporal Adaptive Reflectance Fusion Model(ESTARFM) algorithm. Piecewise logistic functions are fit to the time series to establish spring leaf-out dates. Acadia National Park, a region frequently affected by coastal clouds, is a particularly useful study area as it falls in a Landsat overlap region and thus offers the possibility of acquiring as many as 4 Landsat observations in a 16 day period. With the recent launch of Sentinel 2A, the community will have routine access to such high spatial and temporal data for phenological monitoring.

  9. Peripheral retinal nonperfusion associated with chronic myeloid leukemia.

    NARCIS (Netherlands)

    Nobacht, S.; Vandoninck, K.F.; Deutman, A.F.; Klevering, B.J.

    2003-01-01

    PURPOSE: To report a case of peripheral retinal nonperfusion and chronic myeloid leukemia in a 23-year-old woman. DESIGN: Observational case report. METHODS: A complete ophthalmic and systemic evaluation was performed. RESULTS: Ophthalmic examination revealed peripheral retinal nonperfusion with

  10. Mechanical and thermal cycling effects on the flexural strength of glass ceramics fused to titanium

    NARCIS (Netherlands)

    Vasquez, Vanessa; Ozcan, Mutlu; Nishioka, Renato; Souza, Rodrigo; Mesquita, Alfredo; Pavanelli, Carlos

    This study evaluated the effects of mechanical and thermal cycling on the flexural strength (ISO 9693) of three brands of ceramics fused to commercially pure titanium (cpTi). Metallic frameworks of 25 x 3 x 0.5 mm dimensions (N = 84) were cast in cpTi, followed by 150-mu m aluminum oxide airborne

  11. Large-area uniform periodic microstructures on fused silica induced by surface phonon polaritons and incident laser

    Science.gov (United States)

    Zhang, Chuanchao; Liao, Wei; Zhang, Lijuan; Jiang, Xiaolong; Chen, Jing; Wang, Haijun; Luan, Xiaoyu; Yuan, Xiaodong

    2018-06-01

    A simple and convenient means to self-organize large-area uniform periodic microstructures on fused silica by using multiple raster scans of microsecond CO2 laser pulses with beam spot overlapping at normal incidence is presented, which is based on laser-induced periodic surface structures (LIPSS) attributed to the interference between surface phonon polaritons and incident CO2 laser. The evolution of fused silica surface morphologies with increasing raster scans indicates that the period of microstructures changed from 10.6 μm to 9 μm and the profiles of microstructures changed from a sinusoidal curve to a half-sinusoidal shape. Numerical simulation results suggest that the formation of the half-sinusoidal profile is due to the exponential relationship between evaporation rate and surface temperature inducing by the intensive interference between surface phonon polaritons and incident laser. The fabricated uniform periodic microstructures show excellent structural color effect in both forward-diffraction and back-diffraction.

  12. New tris- and pentakis-fused donors containing extended tetrathiafulvalenes: New positive electrode materials for rechargeable batteries

    Directory of Open Access Journals (Sweden)

    Shintaro Iwamoto

    2015-07-01

    Full Text Available Derivatives of tris-fused TTF extended with two ethanediylidenes (5, tris- and pentakis-fused TTFs extended with two thiophene-2,5-diylidenes (6–9 were successfully synthesized. Cyclic voltammograms of the tetrakis(n-hexylthio derivative of 5 and 7 (5d, 7d consisted of two pairs of two-electron redox waves and two pairs of one-electron redox waves. On the other hand, four pairs of two-electron redox waves and two pairs of one-electron redox waves were observed for the tetrakis(n-hexylthio derivative of 9 (9d. Coin-type cells using the bis(ethylenedithio derivatives of 5 (5b, 6 (6b and the tetrakis(methylthio derivatives of 5 (5c and 8 (8c as positive electrode materials showed initial discharge capacities of 157–190 mAh g−1 and initial energy densities of 535–680 mAh g−1. The discharge capacities after 40 cycles were 64–86% of the initial discharge capacities.

  13. Proximal dominant hereditary motor and sensory neuropathy with proximal dominance association with mutation in the TRK-fused gene.

    Science.gov (United States)

    Lee, Sang-Soo; Lee, Hye Jin; Park, Jin-Mo; Hong, Young Bin; Park, Kee-Duk; Yoo, Jeong Hyun; Koo, Heasoo; Jung, Sung-Chul; Park, Hyung Soon; Lee, Ji Hyun; Lee, Min Goo; Hyun, Young Se; Nakhro, Khriezhanou; Chung, Ki Wha; Choi, Byung-Ok

    2013-05-01

    Hereditary motor and sensory neuropathy with proximal dominance (HMSN-P) has been reported as a rare type of autosomal dominant adult-onset Charcot-Marie-Tooth disease. HMSN-P has been described only in Japanese descendants since 1997, and the causative gene has not been found. To identify the genetic cause of HMSN-P in a Korean family and determine the pathogenic mechanism. Genetic and observational analysis. Translational research center for rare neurologic disease. Twenty-eight individuals (12 men and 16 women) from a Korean family with HMSN-P. Whole-exome sequencing, linkage analysis, and magnetic resonance imaging. Through whole-exome sequencing, we revealed that HMSN-P is caused by a mutation in the TRK-fused gene (TFG). Clinical heterogeneities were revealed in HMSN-P between Korean and Japanese patients. The patients in the present report showed faster progression of the disease compared with the Japanese patients, and sensory nerve action potentials of the sural nerve were lost in the early stages of the disease. Moreover, tremor and hyperlipidemia were frequently found. Magnetic resonance imaging of the lower extremity revealed a distinct proximal dominant and sequential pattern of muscular involvement with a clearly different pattern than patients with Charcot-Marie-Tooth disease type 1A. Particularly, endoneural blood vessels revealed marked narrowing of the lumen with swollen vesicular endothelial cells. The underlying cause of HMSN-P proves to be a mutation in TFG that lies on chromosome 3q13.2. This disease is not limited to Japanese descendants, and marked narrowing of endoneural blood vessels was noted in the present study. We believe that TFG can affect the peripheral nerve tissue.

  14. The clinical identification of peripheral neuropathy among older persons.

    Science.gov (United States)

    Richardson, James K

    2002-11-01

    To identify simple clinical rules for the detection of a diffuse peripheral neuropathy among older outpatients. Observational, blinded, controlled study. A tertiary-care electrodiagnostic laboratory and biomechanics laboratory. One hundred research subjects, 68 with electrodiagnostic evidence of peripheral neuropathy, between the ages of 50 and 80 years. Not applicable. One examiner, unaware of the results of electrodiagnostic testing, evaluated Achilles' and patellar reflexes, Romberg testing, semiquantified vibration, and position sense at the toe and ankle in all subjects, and unipedal stance time and the Michigan Diabetes Neuropathy Score in a subset of subjects. Significant group differences were present in all clinical measures tested. Three signs, Achilles' reflex (absent despite facilitation), vibration (128Hz tuning fork perceived for <10s), and position sense (<8/10 1-cm trials) at the toe, were the best predictors of peripheral neuropathy on both univariate and logistic regression (pseudo R(2)=.744) analyses. The presence of 2 or 3 signs versus 0 or 1 sign identified peripheral neuropathy with sensitivity, specificity, and positive and negative predictive values of 94.1%, 84.4%, 92.8%, and 87.1%, respectively. Values were similar among subgroups of subjects with and without diabetes mellitus. When other clinicians applied the technique to 12 more subjects, excellent interrater reliability regarding the presence of peripheral neuropathy (kappa=.833) and good to excellent interrater reliability for each sign (kappa range,.667-1.00) were shown. Among older persons, the presence of 2 or 3 of the 3 clinical signs strongly suggested electrodiagnostic evidence of a peripheral neuropathy, regardless of etiology. Age-related decline in peripheral nerve function need not be a barrier to the clinical recognition of a diffuse peripheral neuropathy among older persons. Copyright 2002 by the American Congress of Rehabilitation Medicine and the American Academy of

  15. Peripheral neuropathy of dietary riboflavin deficiency in racing pigeons.

    Science.gov (United States)

    Wada, Y; Kondo, H; Itakura, C

    1996-02-01

    An occurrence of peripheral neuropathy in nine 14- to 55-day-old racing pigeons was documented. The predominant clinical signs were diarrhea, and leg and wing paralysis. Grossly, there was discoloration and swelling of all the peripheral nerve trunks. Microscopic lesions comprising swelling, fragmentation and demyelination of myelin sheaths, and proliferation of Schwann cells, were seen in the peripheral nerves of all birds examined. These changes were associated with moderate to severe swelling, fragmentation, atrophy and loss of axons. The peripheral nerve lesions in these cases were similar to those of dietary riboflavin deficiency in chickens. An analysis of the diet given to the pigeons indicated that the riboflavin concentration was only 0.9 mg/kg feed.

  16. Malignant Peripheral Nerve Sheath Tumour of the Maxilla

    Directory of Open Access Journals (Sweden)

    Puja Sahai

    2014-01-01

    Full Text Available A 38-year-old man was diagnosed with malignant peripheral nerve sheath tumour of the maxilla. He was treated with total maxillectomy. Histopathological examination of the resected specimen revealed a close resection margin. The tumour was of high grade with an MIB-1 labelling index of almost 60%. At six weeks following the surgery, he developed local tumour relapse. The patient succumbed to the disease at five months from the time of diagnosis. The present report underlines the locally aggressive nature of malignant peripheral nerve sheath tumour of the maxilla which necessitates an early therapeutic intervention. A complete resection with clear margins is the most important prognostic factor for malignant peripheral nerve sheath tumour in the head and neck region. Adjuvant radiotherapy may be considered to improve the local control. Future research may demarcate the role of targeted therapy for patients with malignant peripheral nerve sheath tumour.

  17. Water soluble peripheral and non-peripheral tetrasubstituted zinc phthalocyanines: Synthesis, photochemistry and bovine serum albumin binding behavior

    Energy Technology Data Exchange (ETDEWEB)

    Çakır, Volkan; Çakır, Dilek [Department of Chemistry, Faculty of Sciences, Karadeniz Technical University, 61080 Trabzon (Turkey); Pişkin, Mehmet [Department of Food Technology, Çanakkale Vocational School of Technical Sciences, Çanakkale Onsekiz Mart University, 17100 Çanakkale (Turkey); Durmuş, Mahmut [Gebze Institute of Technology, Department of Chemistry, PO Box 141, Gebze 41400, Kocaeli (Turkey); Bıyıklıoğlu, Zekeriya, E-mail: zekeriya_61@yahoo.com [Department of Chemistry, Faculty of Sciences, Karadeniz Technical University, 61080 Trabzon (Turkey)

    2014-10-15

    The new peripherally and non-peripherally tetra-1,3-bis[3-(diethylamino)phenoxy]propan-2-ol substituted zinc(II) phthalocyanine complexes (2a and 3a) and their quaternized amphiphilic derivatives (2b and 3b) have been synthesized and characterized using UV–vis, FT-IR, {sup 1}H-NMR, {sup 13}C-NMR, MS spectroscopic data and elemental analysis for the first time. The quaternized complexes (2b and 3b) show excellent solubility in water and DMSO which makes them potential photosensitizers for use in photodynamic therapy (PDT) of cancer. The photochemical (singlet oxygen generation and photodegradation under light irradiation) properties of these novel phthalocyanines are investigated in dimethylsulfoxide (DMSO) for non-quaternized complexes and in DMSO, phosphate buffered solution (PBS) or PBS+triton X-100 (TX) solution for quaternized complexes. In this study, the effects of the aggregation of the molecules, quaternization, position of the substituents (peripherally or non-peripherally) and nature of the solvents (DMSO, PBS or PBS+triton X-100) on the photochemical parameters of the zinc (II) phthalocyanines are also reported. In addition, a spectroscopic investigation of the binding behavior of the quaternized zinc(II) phthalocyanine complexes to bovine serum albumin (BSA) is also presented in this work. - Highlights: • Synthesis of zinc phthalocyanines is performed. • Photophysical and photochemical properties of phthalocyanines are studied. • Photodynamic therapy studies are performed.

  18. Water soluble peripheral and non-peripheral tetrasubstituted zinc phthalocyanines: Synthesis, photochemistry and bovine serum albumin binding behavior

    International Nuclear Information System (INIS)

    Çakır, Volkan; Çakır, Dilek; Pişkin, Mehmet; Durmuş, Mahmut; Bıyıklıoğlu, Zekeriya

    2014-01-01

    The new peripherally and non-peripherally tetra-1,3-bis[3-(diethylamino)phenoxy]propan-2-ol substituted zinc(II) phthalocyanine complexes (2a and 3a) and their quaternized amphiphilic derivatives (2b and 3b) have been synthesized and characterized using UV–vis, FT-IR, 1 H-NMR, 13 C-NMR, MS spectroscopic data and elemental analysis for the first time. The quaternized complexes (2b and 3b) show excellent solubility in water and DMSO which makes them potential photosensitizers for use in photodynamic therapy (PDT) of cancer. The photochemical (singlet oxygen generation and photodegradation under light irradiation) properties of these novel phthalocyanines are investigated in dimethylsulfoxide (DMSO) for non-quaternized complexes and in DMSO, phosphate buffered solution (PBS) or PBS+triton X-100 (TX) solution for quaternized complexes. In this study, the effects of the aggregation of the molecules, quaternization, position of the substituents (peripherally or non-peripherally) and nature of the solvents (DMSO, PBS or PBS+triton X-100) on the photochemical parameters of the zinc (II) phthalocyanines are also reported. In addition, a spectroscopic investigation of the binding behavior of the quaternized zinc(II) phthalocyanine complexes to bovine serum albumin (BSA) is also presented in this work. - Highlights: • Synthesis of zinc phthalocyanines is performed. • Photophysical and photochemical properties of phthalocyanines are studied. • Photodynamic therapy studies are performed

  19. Demographic processes of developmentally peripheral areas in Hungary

    Directory of Open Access Journals (Sweden)

    Pénzes János

    2015-01-01

    Full Text Available The current study investigates the demographic processes and challenges of the Hungarian developmentally peripheral settlements. Demographic challenges can be regarded as important consequences of the social and economic disadvantages in spatial terms. However, the interrelating negative demographic tendencies cause even more backward situation blocking or hindering the development. The objective of the current analysis is to discover the demographic characteristics of the peripheral settlements, to detect the spatial disparities and to point out the correlation between backwardness and the investigated demographic phenomena with the help of the census databases 1980-2011 and local datasets on Roma population. Using methods of multivariate statistical analysis, seven indicators were selected in order to achieve the goals of the paper. Backward areas are primarily characterized by population decrease with significant disparities, but there were growing communities among them as well. Some small villages in Northern and Southwestern Hungary will foreseeably face complete depopulation within few years. Primarily small sized villages faced intense decrease in rate of natural change, but dynamic population growth was also detected. Migration loss tends to correlate with the extent of peripherality, as increasing values of migration balance accompany decreasing ratio of peripheral settlements in the area. The ratio of elderly population shows an expressively two-faced character, with the extremely aging and very juvenile settlements. The ratios of Roma population reflect the scale of peripherality. Extended ethnic change could be predicted in Northeastern and Southwestern Hungary and near the Middle Tisza valley. Presented demographic processes will make the backwardness of most of the peripheral settlements stable.

  20. A Novel Synthesis of Fused Uracils: Indenopyrimidopyridazines, Pyrimidopyridazines, and Pyrazolopyrimidines for Antimicrobial and Antitumor Evalution

    Directory of Open Access Journals (Sweden)

    Samar El-Kalyoubi

    2016-12-01

    Full Text Available A variety of different compounds of fused uracils were prepared simply by the heating of 6-hydrazinyl-1-methyl-, 6-hydrazinyl-1-propyl-, or 6-hydrazinyl-1,3-dipropyluracil under reflux with ninhydrin, isatin, benzylidene malononitrile, benzylylidene ethyl cyanoacetate, benzil, and phenacyl bromide derivatives. The newly synthesized compounds were completely screened for antimicrobial and antitumor activity.

  1. Optical coherent tomography in diagnoses of peripheral retinal degenarations

    OpenAIRE

    O. G. Pozdeyeva; T. B. Shaimov; A. Yu. Galin; R. B. Shaimov; T. A. Shaimova; A. V. Zolotova; A. V. Fomin

    2014-01-01

    Purpose: Studying the capabilities of optical coherence tomography (RTVue-100, OPTOVUE, USA) in evaluation of peripheral retinal degenerations, vitreoretinal adhesions, adjacent vitreous body as well as measurement of morphometric data.Methods: The study included 189 patients (239 eyes) with peripheral retinal degeneration. 77 men and 112 women aged 18 to 84 underwent an ophthalmologic examination since November 2012 until October 2013. The peripheral retina was visualized with the help of op...

  2. Clinical impact of exercise in patients with peripheral arterial disease.

    Science.gov (United States)

    Novakovic, Marko; Jug, Borut; Lenasi, Helena

    2017-08-01

    Increasing prevalence, high morbidity and mortality, and decreased health-related quality of life are hallmarks of peripheral arterial disease. About one-third of peripheral arterial disease patients have intermittent claudication with deleterious effects on everyday activities, such as walking. Exercise training improves peripheral arterial disease symptoms and is recommended as first line therapy for peripheral arterial disease. This review examines the effects of exercise training beyond improvements in walking distance, namely on vascular function, parameters of inflammation, activated hemostasis and oxidative stress, and quality of life. Exercise training not only increases walking distance and physiologic parameters in patients with peripheral arterial disease, but also improves the cardiovascular risk profile by helping patients achieve better control of hypertension, hyperglycemia, obesity and dyslipidemia, thus further reducing cardiovascular risk and the prevalence of coexistent atherosclerotic diseases. American guidelines suggest supervised exercise training, performed for a minimum of 30-45 min, at least three times per week, for at least 12 weeks. Walking is the most studied exercise modality and its efficacy in improving cardiovascular parameters in patients with peripheral arterial disease has been extensively proven. As studies have shown that supervised exercise training improves walking performance, cardiovascular parameters and quality of life in patients with peripheral arterial disease, it should be encouraged and more often prescribed.

  3. Cloud Detection by Fusing Multi-Scale Convolutional Features

    Science.gov (United States)

    Li, Zhiwei; Shen, Huanfeng; Wei, Yancong; Cheng, Qing; Yuan, Qiangqiang

    2018-04-01

    Clouds detection is an important pre-processing step for accurate application of optical satellite imagery. Recent studies indicate that deep learning achieves best performance in image segmentation tasks. Aiming at boosting the accuracy of cloud detection for multispectral imagery, especially for those that contain only visible and near infrared bands, in this paper, we proposed a deep learning based cloud detection method termed MSCN (multi-scale cloud net), which segments cloud by fusing multi-scale convolutional features. MSCN was trained on a global cloud cover validation collection, and was tested in more than ten types of optical images with different resolution. Experiment results show that MSCN has obvious advantages over the traditional multi-feature combined cloud detection method in accuracy, especially when in snow and other areas covered by bright non-cloud objects. Besides, MSCN produced more detailed cloud masks than the compared deep cloud detection convolution network. The effectiveness of MSCN make it promising for practical application in multiple kinds of optical imagery.

  4. Peripheral Arterial Disease Study (PERART: Prevalence and predictive values of asymptomatic peripheral arterial occlusive disease related to cardiovascular morbidity and mortality

    Directory of Open Access Journals (Sweden)

    Bundó Magda

    2007-12-01

    Full Text Available Abstract Background The early diagnosis of atherosclerotic disease is essential for developing preventive strategies in populations at high risk and acting when the disease is still asymptomatic. A low ankle-arm index (AAI is a good marker of vascular events and may be diminished without presenting symptomatology (silent peripheral arterial disease. The aim of the PERART study (PERipheral ARTerial disease is to determine the prevalence of peripheral arterial disease (both silent and symptomatic in a general population of both sexes and determine its predictive value related to morbimortality (cohort study. Methods/Design This cross-over, cohort study consists of 2 phases: firstly a descriptive, transversal cross-over study to determine the prevalence of peripheral arterial disease, and secondly, a cohort study to evaluate the predictive value of AAI in relation to cardiovascular morbimortality. From September 2006 to June 2007, a total of 3,010 patients over the age of 50 years will be randomly selected from a population adscribed to 24 healthcare centres in the province of Barcelona (Spain. The diagnostic criteria of peripheral arterial disease will be considered as an AAI Discussion In this study we hope to determine the prevalence of peripheral arterial disease, especially the silent forms, in the general population and establish its relationship with cardiovascular morbimortality. A low AAI may be a better marker of arterial disease than the classical cardiovascular risk factors and may, therefore, contribute to improving the predictive value of the equations of cardiovascular risk and thereby allowing optimisation of multifactorial treatment of atherosclerotic disease.

  5. Consequences of peripheral frequency selectivity for nonsimultaneous masking

    NARCIS (Netherlands)

    Duifhuis, H.

    1973-01-01

    The frequency selectivity of the peripheral ear (e.g., at the VIIIth nerve level) is so acute that onset and offset transients in responses to short signals produce a nonnegligible extension of the signal duration. Thus, peripheral excitation patterns produced by signals which were separated in time

  6. Atherectomy in Peripheral Artery Disease: A Review.

    Science.gov (United States)

    Bhat, Tariq M; Afari, Maxwell E; Garcia, Lawrence A

    2017-04-01

    Peripheral arterial disease (PAD) is a clinical manifestation of systemic atherosclerosis and is associated with significant morbidity and mortality. The physiological force and shear stress from angioplasty and stenting have made PAD treatment challenging. Atherectomy devices have continued to emerge as a major therapy in the management of peripheral vascular disease. This article presents a review of the current literature for the atherectomy devices used in PAD.

  7. Detecting peripheral-based attacks on the host memory

    CERN Document Server

    Stewin, Patrick

    2015-01-01

    This work addresses stealthy peripheral-based attacks on host computers and presents a new approach to detecting them. Peripherals can be regarded as separate systems that have a dedicated processor and dedicated runtime memory to handle their tasks. The book addresses the problem that peripherals generally communicate with the host via the host’s main memory, storing cryptographic keys, passwords, opened files and other sensitive data in the process – an aspect attackers are quick to exploit.  Here, stealthy malicious software based on isolated micro-controllers is implemented to conduct an attack analysis, the results of which provide the basis for developing a novel runtime detector. The detector reveals stealthy peripheral-based attacks on the host’s main memory by exploiting certain hardware properties, while a permanent and resource-efficient measurement strategy ensures that the detector is also capable of detecting transient attacks, which can otherwise succeed when the applied strategy only me...

  8. Intravenous Lidocaine Infusion to Treat Chemotherapy-Induced Peripheral Neuropathy.

    Science.gov (United States)

    Papapetrou, Peter; Kumar, Aashish J; Muppuri, Rudram; Chakrabortty, Shushovan

    2015-11-01

    Chemotherapy-induced peripheral neuropathy is a debilitating side effect of chemotherapy, which manifests as paresthesias, dysesthesias, and numbness in the hands and feet. Numerous chemoprotective agents and treatments have been used with limited success to treat chemotherapy-induced peripheral neuropathy. We report a case in which a patient presenting with chemotherapy-induced peripheral neuropathy received an IV lidocaine infusion over the course of 60 minutes with complete symptomatic pain relief for a prolonged period of 2 weeks.

  9. Computed tomographic findings of intrahepatic peripheral cholangiocarcinoma

    International Nuclear Information System (INIS)

    Woo, Seong Ku; Suh, Soo Jhi; Kim, Ho Joon; Chun, Byung Hee

    1986-01-01

    Cholangiocarcinoma is synonymous with bile duct carcinoma, and can originate in a small intrahepatic bile duct (peripheral type), a major intrahepatic duct including the hepatic hills, an extrahepatic duct, or near the papilla of Vater (central type). In a sense bile duct carcinoma of the peripheral type is cholangiocarcinoma of the liver; it has the same gross configuration as hepatocellular carcinoma, resulting in difficulty to differentiate on the CT. The authors studied CT findings of 14 cases of pathologically proven peripheral type cholangiocarcinoma of the liver during the last 4 years. The results were as follows: 1. Of 14 cases, 8 were female and 6 were male, and the age ranged from 5th to 7th decades. 2. Preoperative clinical diagnosis were as follows: hepatoma 8 cases, abscess 5 cases and metastasis 1 case in order of frequency. 3. Diagnosis were confirmed by hepatic lobectomy in 7 cases, wedge resection in 5 cases and needle biopsy in 2 case. 4. Laboratory findings were not specific, but there were only 2 cases with elevated alpha-fetoprotein level. 5. Associated diseases were gallstones in 1 case, intrahepatic duct stones in 1 case, extrahepatic duct stones in 2 cases, acute or chronic cholecystitis in 5 cases and CS in 3 cases. 6. Angiographic and scintigraphic findings were helpful in differential diagnosis from hepatoma but ultrasonography was non-specific. 7. The number of tumor were solitary in 12 cases and multiple in 2 cases. Among solitary cases, the site of involvement of the liver were right lobe in 8 cases and left lobe in 4 cases. 8. Common CT features of the intrahepatic peripheral cholangiocinoma of the liver were irregular, inhomogeneous, occasionally peripherally enhancing, low density liver mass, frequently accompanied by diffuse or segmental dilatation of the intrahepatic bile duct. If there were normal alpha fetoprotein level, positive skin and/or stool examination for CS and diffuse or segmental dilatation of the intrahepatic duct

  10. Diabetes and obesity are the main metabolic drivers of peripheral neuropathy.

    Science.gov (United States)

    Callaghan, Brian C; Gao, LeiLi; Li, Yufeng; Zhou, Xianghai; Reynolds, Evan; Banerjee, Mousumi; Pop-Busui, Rodica; Feldman, Eva L; Ji, Linong

    2018-04-01

    To determine the associations between individual metabolic syndrome (MetS) components and peripheral neuropathy in a large population-based cohort from Pinggu, China. A cross-sectional, randomly selected, population-based survey of participants from Pinggu, China was performed. Metabolic phenotyping and neuropathy outcomes were performed by trained personnel. Glycemic status was defined according to the American Diabetes Association criteria, and the MetS using modified consensus criteria (body mass index instead of waist circumference). The primary peripheral neuropathy outcome was the Michigan Neuropathy Screening Instrument (MNSI) examination. Secondary outcomes were the MNSI questionnaire and monofilament testing. Multivariable models were used to assess for associations between individual MetS components and peripheral neuropathy. Tree-based methods were used to construct a classifier for peripheral neuropathy using demographics and MetS components. The mean (SD) age of the 4002 participants was 51.6 (11.8) and 51.0% were male; 37.2% of the population had normoglycemia, 44.0% prediabetes, and 18.9% diabetes. The prevalence of peripheral neuropathy increased with worsening glycemic status (3.25% in normoglycemia, 6.29% in prediabetes, and 15.12% in diabetes, P peripheral neuropathy. Age, diabetes, and weight were the primary splitters in the classification tree for peripheral neuropathy. Similar to previous studies, diabetes and obesity are the main metabolic drivers of peripheral neuropathy. The consistency of these results reinforces the urgent need for effective interventions that target these metabolic factors to prevent and/or treat peripheral neuropathy.

  11. Registry Assessment of Peripheral Interventional Devices (RAPID): Registry assessment of peripheral interventional devices core data elements.

    Science.gov (United States)

    Jones, W Schuyler; Krucoff, Mitchell W; Morales, Pablo; Wilgus, Rebecca W; Heath, Anne H; Williams, Mary F; Tcheng, James E; Marinac-Dabic, J Danica; Malone, Misti L; Reed, Terrie L; Fukaya, Rie; Lookstein, Robert A; Handa, Nobuhiro; Aronow, Herbert D; Bertges, Daniel J; Jaff, Michael R; Tsai, Thomas T; Smale, Joshua A; Zaugg, Margo J; Thatcher, Robert J; Cronenwett, Jack L

    2018-02-01

    The current state of evaluating patients with peripheral artery disease and more specifically of evaluating medical devices used for peripheral vascular intervention (PVI) remains challenging because of the heterogeneity of the disease process, the multiple physician specialties that perform PVI, the multitude of devices available to treat peripheral artery disease, and the lack of consensus about the best treatment approaches. Because PVI core data elements are not standardized across clinical care, clinical trials, and registries, aggregation of data across different data sources and physician specialties is currently not feasible. Under the auspices of the U.S. Food and Drug Administration's Medical Device Epidemiology Network initiative-and its PASSION (Predictable and Sustainable Implementation of the National Registries) program, in conjunction with other efforts to align clinical data standards-the Registry Assessment of Peripheral Interventional Devices (RAPID) workgroup was convened. RAPID is a collaborative, multidisciplinary effort to develop a consensus lexicon and to promote interoperability across clinical care, clinical trials, and national and international registries of PVI. The current manuscript presents the initial work from RAPID to standardize clinical data elements and definitions, to establish a framework within electronic health records and health information technology procedural reporting systems, and to implement an informatics-based approach to promote the conduct of pragmatic clinical trials and registry efforts in PVI. Ultimately, we hope this work will facilitate and improve device evaluation and surveillance for patients, clinicians, health outcomes researchers, industry, policymakers, and regulators. Copyright © 2017 Society for Vascular Surgery. All rights reserved.

  12. Carvedilol prevents functional deficits in peripheral nerve mitochondria of rats with oxaliplatin-evoked painful peripheral neuropathy

    International Nuclear Information System (INIS)

    Areti, Aparna; Komirishetty, Prashanth; Kumar, Ashutosh

    2017-01-01

    Oxaliplatin use as chemotherapeutic agent is frequently limited by cumulative neurotoxicity which may compromise quality of life. Reports relate this neurotoxic effect to oxidative stress and mitochondrial dysfunction in peripheral nerves and dorsal root ganglion (DRG). Carvedilol is an antihypertensive drug, has also been appreciated for its antioxidant and mitoprotective properties. Carvedilol co-treatment did not reduce the anti-tumor effects of oxaliplatin in human colon cancer cells (HT-29), but exhibited free radical scavenging activity against oxaliplatin-induced oxidative stress in neuronal cells (Neuro-2a). Hence, the present study was designed to investigate the effect of carvedilol in the experimental model of oxaliplatin-induced peripheral neuropathy (OIPN) in Sprague-Dawley rats. Oxaliplatin reduced the sensory nerve conduction velocity and produced the thermal and mechanical nociception. Carvedilol significantly (P < 0.001) attenuated these functional and sensorimotor deficits. It also counteracted oxidative/nitrosative stress by reducing the levels of nitrotyrosine and improving the mitochondrial superoxide dismutase expression in both sciatic nerve and DRG tissues. It improved the mitochondrial function and prevented the oxaliplatin-induced alteration in mitochondrial membrane potential in sciatic nerve thus prevented loss of intra epidermal nerve fiber density in the foot pads. Together the results prompt the use of carvedilol along with chemotherapy with oxaliplatin to prevent the peripheral neuropathy. - Graphical abstract: Schematic representation neuroprotective mechanisms of carvedilol in oxaliplatin-induced peripheral neuropathy. - Highlights: • Oxaliplatin-induced mitochondrial dysfunction causes neurotoxicity. • Mitochondrial dysfunction leads to bioenergetic and functional deficits. • Carvedilol alleviated oxaliplatin-induced behavioural and functional changes. • Targeting mitochondria with carvedilol attenuated neuropathic pain.

  13. Carvedilol prevents functional deficits in peripheral nerve mitochondria of rats with oxaliplatin-evoked painful peripheral neuropathy

    Energy Technology Data Exchange (ETDEWEB)

    Areti, Aparna; Komirishetty, Prashanth; Kumar, Ashutosh, E-mail: ashutosh.niperhyd@gov.in

    2017-05-01

    Oxaliplatin use as chemotherapeutic agent is frequently limited by cumulative neurotoxicity which may compromise quality of life. Reports relate this neurotoxic effect to oxidative stress and mitochondrial dysfunction in peripheral nerves and dorsal root ganglion (DRG). Carvedilol is an antihypertensive drug, has also been appreciated for its antioxidant and mitoprotective properties. Carvedilol co-treatment did not reduce the anti-tumor effects of oxaliplatin in human colon cancer cells (HT-29), but exhibited free radical scavenging activity against oxaliplatin-induced oxidative stress in neuronal cells (Neuro-2a). Hence, the present study was designed to investigate the effect of carvedilol in the experimental model of oxaliplatin-induced peripheral neuropathy (OIPN) in Sprague-Dawley rats. Oxaliplatin reduced the sensory nerve conduction velocity and produced the thermal and mechanical nociception. Carvedilol significantly (P < 0.001) attenuated these functional and sensorimotor deficits. It also counteracted oxidative/nitrosative stress by reducing the levels of nitrotyrosine and improving the mitochondrial superoxide dismutase expression in both sciatic nerve and DRG tissues. It improved the mitochondrial function and prevented the oxaliplatin-induced alteration in mitochondrial membrane potential in sciatic nerve thus prevented loss of intra epidermal nerve fiber density in the foot pads. Together the results prompt the use of carvedilol along with chemotherapy with oxaliplatin to prevent the peripheral neuropathy. - Graphical abstract: Schematic representation neuroprotective mechanisms of carvedilol in oxaliplatin-induced peripheral neuropathy. - Highlights: • Oxaliplatin-induced mitochondrial dysfunction causes neurotoxicity. • Mitochondrial dysfunction leads to bioenergetic and functional deficits. • Carvedilol alleviated oxaliplatin-induced behavioural and functional changes. • Targeting mitochondria with carvedilol attenuated neuropathic pain.

  14. Rag Deletion in Peripheral T Cells Blocks TCR Revision

    Science.gov (United States)

    Hale, J. Scott; Ames, Kristina T.; Boursalian, Tamar E.; Fink, Pamela J.

    2010-01-01

    Mature CD4+Vβ5+ T cells that recognize a peripherally expressed endogenous superantigen are tolerized either by deletion or T cell receptor (TCR) revision. In Vβ5 transgenic mice, this latter tolerance pathway results in the appearance of CD4+Vβ5−TCRβ+ T cells, coinciding with Rag1, Rag2, and TdT expression and the accumulation of Vβ-DJβ recombination intermediates in peripheral CD4+ T cells. Because post-thymic RAG-dependent TCR rearrangement has remained controversial, we sought to definitively determine whether TCR revision is an extrathymic process that occurs in mature peripheral T cells. We now show that Rag deletion in post-positive selection T cells in Vβ5 transgenic mice blocks TCR revision in vivo, and that mature peripheral T cells sorted to remove cells bearing endogenous TCRβ chains can express newly generated TCRβ molecules in adoptive hosts. These findings unambiguously demonstrate post-thymic, RAG-dependent TCR rearrangement and define TCR revision as a tolerance pathway that targets mature peripheral CD4+ T cells. PMID:20435935

  15. Chemotherapy-induced peripheral neuropathy: an update on the current understanding.

    Science.gov (United States)

    Addington, James; Freimer, Miriam

    2016-01-01

    Chemotherapy-induced peripheral neuropathy is a common side effect of selected chemotherapeutic agents. Previous work has suggested that patients often under report the symptoms of chemotherapy-induced peripheral neuropathy and physicians fail to recognize the presence of such symptoms in a timely fashion. The precise pathophysiology that underlies chemotherapy-induced peripheral neuropathy, in both the acute and the chronic phase, remains complex and appears to be medication specific. Recent work has begun to demonstrate and further clarify potential pathophysiological processes that predispose and, ultimately, lead to the development of chemotherapy-induced peripheral neuropathy. There is increasing evidence that the pathway to neuropathy varies with each agent. With a clearer understanding of how these agents affect the peripheral nervous system, more targeted treatments can be developed in order to optimize treatment and prevent long-term side effects.

  16. Liposomes to target peripheral neurons and Schwann cells.

    Directory of Open Access Journals (Sweden)

    Sooyeon Lee

    Full Text Available While a wealth of literature for tissue-specific liposomes is emerging, optimal formulations to target the cells of the peripheral nervous system (PNS are lacking. In this study, we asked whether a novel formulation of phospholipid-based liposomes could be optimized for preferential uptake by microvascular endothelia, peripheral neurons and Schwann cells. Here, we report a unique formulation consisting of a phospholipid, a polymer surfactant and cholesterol that result in enhanced uptake by targeted cells. Using fluorescently labeled liposomes, we followed particle internalization and trafficking through a distinct route from dextran and escape from degradative compartments, such as lysosomes. In cultures of non-myelinating Schwann cells, liposomes associate with the lipid raft marker Cholera toxin, and their internalization is inhibited by disruption of lipid rafts or actin polymerization. In contrast, pharmacological inhibition of clathrin-mediated endocytosis does not significantly impact liposome entry. To evaluate the efficacy of liposome targeting in tissues, we utilized myelinating explant cultures of dorsal root ganglia and isolated diaphragm preparations, both of which contain peripheral neurons and myelinating Schwann cells. In these models, we detected preferential liposome uptake into neurons and glial cells in comparison to surrounding muscle tissue. Furthermore, in vivo liposome administration by intramuscular or intravenous injection confirmed that the particles were delivered to myelinated peripheral nerves. Within the CNS, we detected the liposomes in choroid epithelium, but not in myelinated white matter regions or in brain parenchyma. The described nanoparticles represent a novel neurophilic delivery vehicle for targeting small therapeutic compounds, biological molecules, or imaging reagents into peripheral neurons and Schwann cells, and provide a major advancement toward developing effective therapies for peripheral

  17. Fused filament 3D printing of ionic polymer-metal composites for soft robotics

    Science.gov (United States)

    Carrico, James D.; Leang, Kam K.

    2017-04-01

    Additive manufacturing techniques are used to create three-dimensional structures with complex shapes and features from polymer and/or metal materials. For example, fused filament three-dimensional (3D) printing utilizes non-electroactive polymers, such as acrylonitrile butadiene styrene (ABS) and polylactic acid (PLA), to build structures and components in a layer-by-layer fashion for a wide variety of applications. Presented here is a summary of recent work on a fused filament 3D-printing technique to create 3D ionic polymer-metal composite (IPMC) structures for applications in soft robotics. The 3D printing technique overcomes some of the limitations of existing manufacturing processes for creating IPMCs, such as limited shapes and sizes and time-consuming manufacturing steps. In the process described, first a precursor material (non-acid Nafion precursor resin) is extruded into a thermoplastic filament for 3D printing. Then, a custom-designed 3D printer is described that utilizes the precursor filament to manufacture custom-shaped structures. Finally, the 3D-printed samples are functionalized by hydrolyzing them in an aqueous solution of potassium hydroxide and dimethyl sulfoxide, followed by application of platinum electrodes. Presented are example 3D-printed single and multi-degree-of-freedom IPMC actuators and characterization results, as well as example soft-robotic devices to demonstrate the potential of this process.

  18. Salient Region Detection by Fusing Foreground and Background Cues Extracted from Single Image

    Directory of Open Access Journals (Sweden)

    Qiangqiang Zhou

    2016-01-01

    Full Text Available Saliency detection is an important preprocessing step in many application fields such as computer vision, robotics, and graphics to reduce computational cost by focusing on significant positions and neglecting the nonsignificant in the scene. Different from most previous methods which mainly utilize the contrast of low-level features, various feature maps are fused in a simple linear weighting form. In this paper, we propose a novel salient object detection algorithm which takes both background and foreground cues into consideration and integrate a bottom-up coarse salient regions extraction and a top-down background measure via boundary labels propagation into a unified optimization framework to acquire a refined saliency detection result. Wherein the coarse saliency map is also fused by three components, the first is local contrast map which is in more accordance with the psychological law, the second is global frequency prior map, and the third is global color distribution map. During the formation of background map, first we construct an affinity matrix and select some nodes which lie on border as labels to represent the background and then carry out a propagation to generate the regional background map. The evaluation of the proposed model has been implemented on four datasets. As demonstrated in the experiments, our proposed method outperforms most existing saliency detection models with a robust performance.

  19. Peripheral phlebitis: a point-prevalence study.

    Science.gov (United States)

    Washington, Georgita T; Barrett, Robin

    2012-01-01

    The purpose of this research study was to determine the factors influencing peripheral phlebitis in the adult medical-surgical population. The authors would then be able to use those data to determine whether a change in practice was warranted. Data collection and analysis of 188 intravenous sites revealed that females with higher doses of medications in intravenous sites of longer dwell times and suboptimal nutrition were at greater risk of developing peripheral phlebitis. The point prevalence was greater than the recommended 5%, which led the authors to review their facility's patient care and documentation practices.

  20. [Degenerative lesions of the peripheral retina].

    Science.gov (United States)

    Conart, J-B; Baron, D; Berrod, J-P

    2014-01-01

    Degenerative lesions of the peripheral retina are present from teenage years onwards and increase with age. These abnormabilities are frequent, some of them being benign while others predispose to retinal tears and detachment. In the latter case, the lesions are rhegmatogenous and may justify prophylactic treatment by laser photocoagulation. We distinguish congenital lesions of the peripheral retina and intraretinal, chorioretinal and vitreoretinal degenerations. The holes and tears observed in 2% of the population consist of round atrophic holes, "horseshoe" tears, oral dialyses and giant tears. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  1. Comparing the use of 4.6 um lasers versus 10.6 um lasers for mitigating damage site growth on fused silica surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Yang, S T; Matthews, M J; Elhadj, S; Cooke, D; Guss, G M; Draggoo, V G; Wegner, P J

    2010-10-21

    The advantage of using mid-infrared (IR) 4.6 {micro}m lasers, versus far-infrared 10.6 {micro}m lasers, for mitigating damage growth on fused silica is investigated. In contrast to fused silica's high absorption at 10.6 {micro}m, silica absorption at 4.6 {micro}m is two orders of magnitude less. The much reduced absorption at 4.6 {micro}m enables deep heat penetration into fused silica when it is heated using the mid-IR laser, which in turn leads to more effective mitigation of damage sites with deep cracks. The advantage of using mid-IR versus far-IR laser for damage growth mitigation under non-evaporative condition is quantified by defining a figure of merit (FOM) that relates the crack healing depth to laser power required. Based on our FOM, we show that for damage cracks up to at least 500 {micro}m in depth, mitigation using a 4.6 {micro}m mid-IR laser is more efficient than mitigation using a 10.6 {micro}m far-IR laser.

  2. Neutronic study of a nuclear reactor of fused salts

    International Nuclear Information System (INIS)

    Garcia B, F. B.; Francois L, J. L.

    2012-10-01

    The reactors of fused salts called Molten Salt Reactor have presented a resurgence of interest in the last decade, due to they have a versatility in particular to operate, either with a thermal or fast neutrons spectrum. The most active development was by the middle of 1950 and principles of 1970 in the Oak Ridge National Laboratory. In this work some developed models are presented particularly and studied with the help of the MCNPX code, for the development of the neutronic study of this reactor, starting of proposed models and from a simple and homogeneous geometry until other more complex models and approximate to more real cases. In particular the geometry conditions and criticality of each model were analyzed, the isotopic balance, as well as the concentrations of the salts and different assigned fuel types. (Author)

  3. F wave index: A diagnostic tool for peripheral neuropathy

    Directory of Open Access Journals (Sweden)

    G R Sathya

    2017-01-01

    Interpretation & conclusions: Our results showed that F wave index in upper limb was significantly lower in patients with peripheral neuropathy than the healthy controls, and could be used for early detection of peripheral neuropathy.

  4. RR Tel: Getting under the Flux Limit - An Observation with FUSE

    Science.gov (United States)

    Sonnenborn, George (Technical Monitor); Kenyon, Scott J.; Sokoloski, Jennifer L.

    2004-01-01

    The goal of our FUSE proposal was to acquire observations of X-ray emission throughout an outburst cycle of a symbiotic stars. If symbiotics are thermonuclear powered, we expect the emission to follow the evolution of a typical classical nova, where soft X-ray emission strengthens as the optical brightness fades. In accretion models, we expect the X-ray emission to follow the behavior exhibited by dwarf novae, where hard X-rays strengthen relative to soft X-rays as the optical brightness fades. During the time period for this grant, we were fortunate that the prototypical symbiotic Z And began a major eruption and is only now returning to quiescence.

  5. Pressure derivatives of elastic moduli of fused quartz to 10 kb

    Science.gov (United States)

    Peselnick, L.; Meister, R.; Wilson, W.H.

    1967-01-01

    Measurements of the longitudinal and shear moduli were made on fused quartz to 10 kb at 24??5??C. The anomalous behavior of the bulk modulus K at low pressure, ???K ???P 0, at higher pressures. The pressure derivative of the rigidity modulus ???G ???P remains constant and negative for the pressure range covered. A 15-kb hydrostatic pressure vessel is described for use with ultrasonic pulse instrumentation for precise measurements of elastic moduli and density changes with pressure. The placing of the transducer outside the pressure medium, and the use of C-ring pressure seals result in ease of operation and simplicity of design. ?? 1967.

  6. Registry Assessment of Peripheral Interventional Devices (RAPID) - Registry Assessment of Peripheral Interventional Devices Core Data Elements.

    Science.gov (United States)

    Jones, W Schuyler; Krucoff, Mitchell W; Morales, Pablo; Wilgus, Rebecca W; Heath, Anne H; Williams, Mary F; Tcheng, James E; Marinac-Dabic, J Danica; Malone, Misti L; Reed, Terrie L; Fukaya, Rie; Lookstein, Robert; Handa, Nobuhiro; Aronow, Herbert D; Bertges, Daniel J; Jaff, Michael R; Tsai, Thomas T; Smale, Joshua A; Zaugg, Margo J; Thatcher, Robert J; Cronenwett, Jack L; Nc, Durham; Md, Silver Spring; Japan, Tokyo; Ny, New York; Ri, Providence; Vt, Burlington; Mass, Newton; Colo, Denver; Ariz, Tempe; Calif, Santa Clara; Minn, Minneapolis; Nh, Lebanon

    2018-01-25

    The current state of evaluating patients with peripheral artery disease and more specifically of evaluating medical devices used for peripheral vascular intervention (PVI) remains challenging because of the heterogeneity of the disease process, the multiple physician specialties that perform PVI, the multitude of devices available to treat peripheral artery disease, and the lack of consensus about the best treatment approaches. Because PVI core data elements are not standardized across clinical care, clinical trials, and registries, aggregation of data across different data sources and physician specialties is currently not feasible.Methods and Results:Under the auspices of the U.S. Food and Drug Administration's Medical Device Epidemiology Network initiative-and its PASSION (Predictable and Sustainable Implementation of the National Registries) program, in conjunction with other efforts to align clinical data standards-the Registry Assessment of Peripheral Interventional Devices (RAPID) workgroup was convened. RAPID is a collaborative, multidisciplinary effort to develop a consensus lexicon and to promote interoperability across clinical care, clinical trials, and national and international registries of PVI. The current manuscript presents the initial work from RAPID to standardize clinical data elements and definitions, to establish a framework within electronic health records and health information technology procedural reporting systems, and to implement an informatics-based approach to promote the conduct of pragmatic clinical trials and registry efforts in PVI. Ultimately, we hope this work will facilitate and improve device evaluation and surveillance for patients, clinicians, health outcomes researchers, industry, policymakers, and regulators.

  7. Enhancement characteristics of benign and malignant focal peripheral nodules in the peripheral zone of the prostate gland studied using contrast-enhanced transrectal ultrasound

    International Nuclear Information System (INIS)

    Tang, J.; Yang, J.-C.; Luo, Y.; Li, J.; Li, Y.; Shi, H.

    2008-01-01

    Aim: To assess the value of contrast-enhanced grey-scale transrectal ultrasound (CETRUS) in predicting the nature of peripheral zone hypoechoic lesions of the prostate. Materials and Methods: Ninety-one patients with peripheral zone hypoechoic lesions on ultrasound were evaluated with CETRUS followed by lesion-specific and sextant transrectal ultrasound-guided biopsies. The enhancement patterns of the lesions were observed and graded subjectively using adjacent peripheral zone tissue as the reference. Time to enhancement (AT), time to peak intensity (TTP) and peak intensity (PI) were quantified within each nodule. Ultrasound findings were correlated with biopsy findings. Results: Transrectal ultrasound-guided biopsy of the hypoechoic lesions revealed prostate cancer in 44 patients and benign prostatic diseases in 47. The intensity of enhancement within the lesions were graded as no enhancement, increased, equal, or decreased compared with adjacent peripheral zone tissue in two, 30, five and seven in the prostate cancer group and 14, 15, four and 14 in the benign group, respectively. The difference was statistically significant (p < 0.05). The peak enhancement intensity was found to be the most optimal discriminatory parameter (area under curve AUC 0.70; 95% CI: 0.58, 0.82). Conclusion: Malignant hypoechoic nodules in the peripheral zone of the prostate are more likely to enhance early and more intensely on CETRUS. A non-enhanced hypoechoic peripheral zone lesion was more likely to be benign

  8. Neurotoxic 1-deoxysphingolipids and paclitaxel-induced peripheral neuropathy

    Science.gov (United States)

    Kramer, Rita; Bielawski, Jacek; Kistner-Griffin, Emily; Othman, Alaa; Alecu, Irina; Ernst, Daniela; Kornhauser, Drew; Hornemann, Thorsten; Spassieva, Stefka

    2015-01-01

    Peripheral neuropathy is a major dose-limiting side effect of paclitaxel and cisplatin chemotherapy. In the current study, we tested the involvement of a novel class of neurotoxic sphingolipids, the 1-deoxysphingolipids. 1-Deoxysphingolipids are produced when the enzyme serine palmitoyltransferase uses l-alanine instead of l-serine as its amino acid substrate. We tested whether treatment of cells with paclitaxel (250 nM, 1 µM) and cisplatin (250 nM, 1 µM) would result in elevated cellular levels of 1-deoxysphingolipids. Our results revealed that paclitaxel, but not cisplatin treatment, caused a dose-dependent elevation of 1-deoxysphingolipids levels and an increase in the message and activity of serine palmitoyltransferase (P peripheral neuropathy symptoms [evaluated by the European Organization for Research and Treatment of Cancer (EORTC) QLQ-chemotherapy-induced peripheral neuropathy-20 (CIPN20) instrument] and the 1-deoxysphingolipid plasma levels (measured by mass spectrometry) in 27 patients with breast cancer who were treated with paclitaxel chemotherapy. Our results showed that there was an association between the incidence and severity of neuropathy and the levels of very-long-chain 1-deoxyceramides such as C24 (P neuropathy (P peripheral neuropathy.—Kramer, R., Bielawski, J., Kistner-Griffin, E., Othman, A., Alecu, I., Ernst, D., Kornhauser, D., Hornemann, T., Spassieva, S. Neurotoxic 1-deoxysphingolipids and paclitaxel-induced peripheral neuropathy. PMID:26198449

  9. Combining electrospinning and fused deposition modeling for the fabrication of a hybrid vascular graft

    International Nuclear Information System (INIS)

    Centola, M; Rainer, A; Trombetta, M; Spadaccio, C; Genovese, J A; De Porcellinis, S

    2010-01-01

    Tissue engineering of blood vessels is a promising strategy in regenerative medicine with a broad spectrum of potential applications. However, many hurdles for tissue-engineered vascular grafts, such as poor mechanical properties, thrombogenicity and cell over-growth inside the construct, need to be overcome prior to the clinical application. To surmount these shortcomings, we developed a poly-l-lactide (PLLA)/poly-ε-caprolactone (PCL) scaffold releasing heparin by a combination of electrospinning and fused deposition modeling technique. PLLA/heparin scaffolds were produced by electrospinning in tubular shape and then fused deposition modeling was used to armor the tube with a single coil of PCL on the outer layer to improve mechanical properties. Scaffolds were then seeded with human mesenchymal stem cells (hMSCs) and assayed in terms of morphology, mechanical tensile strength, cell viability and differentiation. This particular scaffold design allowed the generation of both a drug delivery system amenable to surmount thrombogenic issues and a microenvironment able to induce endothelial differentiation. At the same time, the PCL external coiling improved mechanical resistance of the microfibrous scaffold. By the combination of two notable techniques in biofabrication-electrospinning and FDM-and exploiting the biological effects of heparin, we developed an ad hoc differentiating device for hMSCs seeding, able to induce differentiation into vascular endothelium.

  10. Thermodynamic properties of thulium and ytterbium in fused NaCl-KCl-CsCl eutectic

    Energy Technology Data Exchange (ETDEWEB)

    Novoselova, A., E-mail: A.Novoselova@ihte.uran.ru [Institute of High-Temperature Electrochemistry, Ural Division, Russian Academy of Science, S. Kovalevskaya Str., 22, Ekaterinburg 620990 (Russian Federation); Smolenski, V. [Institute of High-Temperature Electrochemistry, Ural Division, Russian Academy of Science, S. Kovalevskaya Str., 22, Ekaterinburg 620990 (Russian Federation)

    2011-07-15

    Research highlights: > Tm and Yb chloride compounds as fission products. > The investigation of electrochemical properties of lanthanides. > Determination of the apparent standard redox potentials of the couple Ln(III)/Ln(II) in fused NaCl-KCl-CsCl eutectic at (823 to 973) K. > The calculation of the basic thermodynamic properties of redox reaction in molten salt. - Abstract: This work presents the results of a study of the Tm{sup 3+}/Tm{sup 2+} and Yb{sup 3+}/Yb{sup 2+} couple redox potentials vs. Cl{sup -}/Cl{sub 2} reference electrode at the temperature range (823 to 973) K in fused NaCl-KCl-CsCl eutectic by direct potentiometric method. Initial concentrations of TmCl{sub 3} and YbCl{sub 3} in solvents did not exceed 5.0 mol%. Basic thermodynamic properties of the reactions TmCl{sub 2(l)} + 1/2 Cl{sub 2(g)} {r_reversible} TmCl{sub 3(l)} and YbCl{sub 2(l)} + 1/2 Cl{sub 2(g)} {r_reversible} YbCl{sub 3(l)} were calculated using the temperature dependencies of apparent standard potentials of the couples E{sub Tm{sup 3+}/Tm{sup 2+*}} and E{sub Yb{sup 3+}/Yb{sup 2+*}}.

  11. Negative regulation of RIG-I-mediated antiviral signaling by TRK-fused gene (TFG) protein

    International Nuclear Information System (INIS)

    Lee, Na-Rae; Shin, Han-Bo; Kim, Hye-In; Choi, Myung-Soo; Inn, Kyung-Soo

    2013-01-01

    Highlights: •TRK-fused gene product (TFG) interacts with TRIM25 upon viral infection. •TFG negatively regulates RIG-I mediated antiviral signaling. •TFG depletion leads to enhanced viral replication. •TFG act downstream of MAVS. -- Abstract: RIG-I (retinoic acid inducible gene I)-mediated antiviral signaling serves as the first line of defense against viral infection. Upon detection of viral RNA, RIG-I undergoes TRIM25 (tripartite motif protein 25)-mediated K63-linked ubiquitination, leading to type I interferon (IFN) production. In this study, we demonstrate that TRK-fused gene (TFG) protein, previously identified as a TRIM25-interacting protein, binds TRIM25 upon virus infection and negatively regulates RIG-I-mediated type-I IFN signaling. RIG-I-mediated IFN production and nuclear factor (NF)-κB signaling pathways were upregulated by the suppression of TFG expression. Furthermore, vesicular stomatitis virus (VSV) replication was significantly inhibited by small inhibitory hairpin RNA (shRNA)-mediated knockdown of TFG, supporting the suppressive role of TFG in RIG-I-mediated antiviral signaling. Interestingly, suppression of TFG expression increased not only RIG-I-mediated signaling but also MAVS (mitochondrial antiviral signaling protein)-induced signaling, suggesting that TFG plays a pivotal role in negative regulation of RNA-sensing, RIG-I-like receptor (RLR) family signaling pathways

  12. Combining electrospinning and fused deposition modeling for the fabrication of a hybrid vascular graft

    Energy Technology Data Exchange (ETDEWEB)

    Centola, M; Rainer, A; Trombetta, M [Laboratory of Chemistry and Biomaterials, CIR-Center of Integrated Research, University Campus Bio-Medico of Rome (Italy); Spadaccio, C; Genovese, J A [Area of Cardiovascular Surgery, CIR-Center of Integrated Research, University Campus Bio-Medico of Rome (Italy); De Porcellinis, S, E-mail: m.trombetta@unicampus.i [Complex Systems and Security Laboratory, CIR-Center of Integrated Research, University Campus Bio-Medico of Rome (Italy)

    2010-03-15

    Tissue engineering of blood vessels is a promising strategy in regenerative medicine with a broad spectrum of potential applications. However, many hurdles for tissue-engineered vascular grafts, such as poor mechanical properties, thrombogenicity and cell over-growth inside the construct, need to be overcome prior to the clinical application. To surmount these shortcomings, we developed a poly-l-lactide (PLLA)/poly-epsilon-caprolactone (PCL) scaffold releasing heparin by a combination of electrospinning and fused deposition modeling technique. PLLA/heparin scaffolds were produced by electrospinning in tubular shape and then fused deposition modeling was used to armor the tube with a single coil of PCL on the outer layer to improve mechanical properties. Scaffolds were then seeded with human mesenchymal stem cells (hMSCs) and assayed in terms of morphology, mechanical tensile strength, cell viability and differentiation. This particular scaffold design allowed the generation of both a drug delivery system amenable to surmount thrombogenic issues and a microenvironment able to induce endothelial differentiation. At the same time, the PCL external coiling improved mechanical resistance of the microfibrous scaffold. By the combination of two notable techniques in biofabrication-electrospinning and FDM-and exploiting the biological effects of heparin, we developed an ad hoc differentiating device for hMSCs seeding, able to induce differentiation into vascular endothelium.

  13. Management of spastic hand by selective peripheral neurotomies ...

    African Journals Online (AJOL)

    Introduction: Selective peripheral neurotomies (SPN) are proposed when spasticity is focalized on muscles that are under the control of a single or few peripheral nerves. Objective: This study was done to evaluate the functional results of SPN of median and ulnar nerves in 10 patients who had spastic hyperflexion of the ...

  14. Peripheral cold acclimatization in Antarctic scuba divers.

    Science.gov (United States)

    Bridgman, S A

    1991-08-01

    Peripheral acclimatization to cold in scuba divers stationed at the British Antarctic Survey's Signy Station was investigated during a year in Antarctica. Five divers and five non-diver controls underwent monthly laboratory tests of index finger immersion in cold water for 30 min. Index finger pulp temperature and time of onset of cold-induced vasodilatation (CIVD) were measured. Pain was recorded with verbal and numerical psychophysical subjective pain ratings. Average finger temperatures and median finger pain from 6-30 min of immersion, maximum finger temperatures during the first CIVD cycle, and finger temperatures at the onset of CIVD were calculated. Comparison of the variables recorded from divers and non-divers were performed with analysis of variance. No significant differences were found among the variables recorded from divers and non-divers. From a review of the literature, divers have responses typical of non-cold-adapted Caucasians. There is, therefore, no evidence that Signy divers peripherally acclimatized to cold. We suggest that these findings occur because either the whole body cooling which divers undergo inhibits peripheral acclimatization or because of insufficiently frequent or severe cold exposure while diving. Further basic studies on the duration, frequency and severity of cold exposure necessary to induce peripheral cold acclimatization are required before this question can be satisfactorily answered.

  15. Pathophysiology of Chemotherapy-Induced Peripheral Neuropathy

    Directory of Open Access Journals (Sweden)

    Hana Starobova

    2017-05-01

    Full Text Available Chemotherapy-induced neuropathy is a common, dose-dependent adverse effect of several antineoplastics. It can lead to detrimental dose reductions and discontinuation of treatment, and severely affects the quality of life of cancer survivors. Clinically, chemotherapy-induced peripheral neuropathy presents as deficits in sensory, motor, and autonomic function which develop in a glove and stocking distribution due to preferential effects on longer axons. The pathophysiological processes are multi-factorial and involve oxidative stress, apoptotic mechanisms, altered calcium homeostasis, axon degeneration and membrane remodeling as well as immune processes and neuroinflammation. This review focusses on the commonly used antineoplastic substances oxaliplatin, cisplatin, vincristine, docetaxel, and paclitaxel which interfere with the cancer cell cycle—leading to cell death and tumor degradation—and cause severe acute and chronic peripheral neuropathies. We discuss drug mechanism of action and pharmacokinetic disposition relevant to the development of peripheral neuropathy, the epidemiology and clinical presentation of chemotherapy-induced neuropathy, emerging insight into genetic susceptibilities as well as current understanding of the pathophysiology and treatment approaches.

  16. Delayed internalization and lack of recycling in a beta2-adrenergic receptor fused to the G protein alpha-subunit

    Directory of Open Access Journals (Sweden)

    Floridi Aristide

    2008-10-01

    Full Text Available Abstract Background Chimeric proteins obtained by the fusion of a G protein-coupled receptor (GPCR sequence to the N-terminus of the G protein α-subunit have been extensively used to investigate several aspects of GPCR signalling. Although both the receptor and the G protein generally maintain a fully functional state in such polypeptides, original observations made using a chimera between the β2-adrenergic receptor (β2AR and Gαs indicated that the fusion to the α-subunit resulted in a marked reduction of receptor desensitization and down-regulation. To further investigate this phenomenon, we have compared the rates of internalization and recycling between wild-type and Gαs-fused β2AR. Results The rate of agonist-induced internalization, measured as the disappearance of cell surface immunofluorescence in HEK293 cells permanently expressing N-terminus tagged receptors, was reduced three-fold by receptor-G protein fusion. However, both fused and non-fused receptors translocated to the same endocytic compartment, as determined by dual-label confocal analysis of cells co-expressing both proteins and transferrin co-localization. Receptor recycling, determined as the reversion of surface immunofluorescence following the addition of antagonist to cells that were previously exposed to agonist, markedly differed between wild-type and fused receptors. While most of the internalized β2AR returned rapidly to the plasma membrane, β2AR-Gαs did not recycle, and the observed slow recovery for the fusion protein immunofluorescence was entirely accounted for by protein synthesis. Conclusion The covalent linkage between β2AR and Gαs does not appear to alter the initial endocytic translocation of the two proteins, although there is reduced efficiency. It does, however, completely disrupt the process of receptor and G protein recycling. We conclude that the physical separation between receptor and Gα is not necessary for the transit to early endosomes

  17. Near- and supercritical water as a diameter manipulation and surface roughening agent in fused silica capillaries

    Czech Academy of Sciences Publication Activity Database

    Karásek, Pavel; Planeta, Josef; Roth, Michal

    2013-01-01

    Roč. 85, č. 1 (2013), s. 327-333 ISSN 0003-2700 R&D Projects: GA ČR(CZ) GAP106/12/0522; GA ČR(CZ) GAP206/11/0138 Institutional support: RVO:68081715 Keywords : supercritical water * fused silica capillary * surface treatment Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 5.825, year: 2013

  18. Urbanization and the Resulting Peripheralization in Solo Raya, Indonesia

    Science.gov (United States)

    Pradoto, W.; Mardiansjah, F. H.; Manullang, O. R.; Putra, A. A.

    2018-02-01

    Dynamic urbanization in Solo Raya, a local term for Surakarta Metropolitan, amongst rapid regional based-urbanization in Indonesia, shows the unbalance pattern of growth. A number of Surakarta City’s peripherals become the newly growing area which is characterized by a well-facilitated region, while the former urbanized areas next to the city center present the declining process. Different socioeconomic development triggers a unique mosaic of socio-spatial pattern, on which the phenomena of peripheralization could be investigated. Urban investment that boosted by the political will of both the national and local government has led to a shift in demographic condition. A relatively massive in-migration has been attracted to the peripheral and creates the new landscape of urban-rural society. Complex dynamic of metropolitan growth and the resulting peripheralization reminds that socio-spatial pattern calls the challenges for managing the rapid change of land use and space use. The pattern of urbanization that differs upon the surrounding areas of Surakarta City would be interesting to be explored. This paper will discuss the conceptual framework of peripheral urbanization and the methodological approach. It is actually the part of ongoing research on peripheralisation in Solo Raya.

  19. Peripheral endocannabinoids regulate skeletal muscle development and maintenance

    Directory of Open Access Journals (Sweden)

    Dongjiao Zhao

    2010-12-01

    Full Text Available As a principal tissue responsible for insulin-mediated glucose uptake, skeletal muscle is important for whole-body health. The role of peripheral endocannabinoids as regulators of skeletal muscle metabolism has recently gained a lot of interest, as endocannabinoid system disorders could cause peripheral insulin resistance. We investigated the role of the peripheral endocannabinoid system in skeletal muscle development and maintenance. Cultures of C2C12 cells, primary satellite cells and mouse skeletal muscle single fibers were used as model systems for our studies. We found an increase in cannabinoid receptor type 1 (CB1 mRNA and endocannabinoid synthetic enzyme mRNA skeletal muscle cells during differentiation. We also found that activation of CB1 inhibited myoblast differentiation, expanded the number of satellite cells, and stimulated the fast-muscle oxidative phenotype. Our findings contribute to understanding of the role of the endocannabinoid system in skeletal muscle metabolism and muscle oxygen consumption, and also help to explain the effects of the peripheral endocannabinoid system on whole-body energy balance.

  20. Wear resistance of a pressable low-fusing ceramic opposed by dental alloys.

    Science.gov (United States)

    Faria, Adriana Cláudia Lapria; de Oliveira, André Almeida; Alves Gomes, Érica; Silveira Rodrigues, Renata Cristina; Faria Ribeiro, Ricardo

    2014-04-01

    Dental alloys have increasingly replaced by dental ceramics in dentistry because of aesthetics. As both dental alloys and ceramics can be present in the oral cavity, the evaluation of the wear resistance of ceramics opposed by dental alloys is important. The aim of the present study was to evaluate wear resistance of a pressable low-fusing ceramic opposed by dental alloys as well as the microhardness of the alloys and the possible correlation of wear and antagonist microhardness. Fifteen stylus tips samples of pressable low-fusing ceramic were obtained, polished and glazed. Samples were divided into three groups according to the disk of alloy/metal to be used as antagonist: Nickel-Chromium (Ni-Cr), Cobalt-Chromium (Co-Cr) and commercially pure titanium (cp Ti). Vickers microhardness of antagonist disks was evaluated before wear tests. Then, antagonist disks were sandblasted until surface roughness was adjusted to 0.75μm. Wear tests were performed at a speed of 60 cycles/min and distance of 10mm, in a total of 300,000 cycles. Before and after wear tests, samples were weighted and had their profile designed in an optical comparator to evaluate weight and height loss, respectively. Ni-Cr and cp Ti caused greater wear than Co-Cr, presenting greater weight (p=.009) and height (p=.002) loss. Cp Ti microhardness was lower than Ni-Cr and Co-Cr (pceramic presents different wear according to the dental alloy used as antagonist and the wear is not affected by antagonist microhardness. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Micromethod for determination of cortisol in peripheral blood

    International Nuclear Information System (INIS)

    Maleeva, A.; Mileva, Zh.; Kekhajova, M.

    1982-01-01

    The micromethod for determination of cortisol in peripheral blood is based on the classical radiommunologic method for its determination. A drop of peripheral blood is applied on filter paper, used for detection of phenyketonuria. A 7 mm disk of this paper is then cut with a perforator and placed in the tube instead of 50 microliters blood plasma. The classical radiommunoassay and the micromethod were used in parallel for determining peripheral blood cortisol concentrations in 26 sexually mature persons, in 12 children and in 40 patients with thyroid hyperfunction. In all tested 78 persons no statistically significant difference (P>0.5) was found in cortisol concentrations, determined by the two methods. (authors)

  2. Effect of peripheral morphine in a human model of acute inflammatory pain

    DEFF Research Database (Denmark)

    Lillesø, J; Hammer, N A; Pedersen, J L

    2000-01-01

    Several studies have demonstrated the presence of opioid inducible receptors on peripheral nerves and peripheral antinociceptive effects of opioids. However, the effects of peripheral opioid administration in man are controversial. Our study used a randomized, double-blind, placebo-controlled, th......Several studies have demonstrated the presence of opioid inducible receptors on peripheral nerves and peripheral antinociceptive effects of opioids. However, the effects of peripheral opioid administration in man are controversial. Our study used a randomized, double-blind, placebo......-controlled, three-way crossover design in a human model of acute inflammatory pain (heat injury). We studied 18 healthy volunteers who each received morphine locally (2 mg), morphine systemically (2 mg), or placebo on three separate study days. The subjects received morphine infiltration subcutaneously (s.c.). 1 h......, but local morphine infiltration neither reduced pain during the burn, nor primary or secondary hyperalgesia to mechanical and heat stimuli after the burn. In conclusion, peripherally applied morphine had no acute antinociceptive effects in this human model of acute inflammatory pain....

  3. Analysis of polycyclic aromatic hydrocarbons I. Determination by gas chromatography with glass and fused silica capillary columns

    International Nuclear Information System (INIS)

    Perez, M. M.; Gonzalez, D.

    1987-01-01

    A study of the analysis by gas chromatography of aromatic polycyclic hydrocarbons is presented. The separation has been carried out by glass and fused silica capillary column. The limitations and the advantages of the procedure are discussed in terms of separation efficiency, sensitivity and precision. (Author) 17 refs

  4. 3D printing of CNT- and graphene-based conductive polymer nanocomposites by fused deposition modeling

    OpenAIRE

    Gnanasekaran, K.; Heijmans, T.; van Bennekom, S.; Woldhuis, H.; Wijnia, S.; de With, G.; Friedrich, H.

    2017-01-01

    Fused deposition modeling (FDM) is limited by the availability of application specific functional materials. Here we illustrate printing of non-conventional polymer nanocomposites (CNT- and graphene-based polybutylene terephthalate (PBT)) on a commercially available desktop 3D printer leading toward printing of electrically conductive structures. The printability, electrical conductivity and mechanical stability of the polymer nanocomposites before and after 3D printing was evaluated. The res...

  5. A bendable and wearable cardiorespiratory monitoring device fusing two noncontact sensor principles.

    Science.gov (United States)

    Teichmann, Daniel; De Matteis, Dennis; Bartelt, Thorsten; Walter, Marian; Leonhardt, Steffen

    2015-05-01

    A mobile device is presented for monitoring both respiration and pulse. The device is developed as a bendable/flexible inlay that can be placed in a shirt pocket or the inside pocket of a jacket. To achieve optimum monitoring performance, the device combines two sensor principles, which work in a safe noncontact way through several layers of cotton or other textiles. One sensor, based on magnetic induction, is intended for respiratory monitoring, and the other is a reflective photoplethysmography sensor intended for pulse detection. Because each sensor signal has some dependence on both physiological parameters, fusing the sensor signals allows enhanced signal coverage.

  6. THREE DIMENSIONAL DIGITIZATION OF HUMAN HEAD BY FUSING STRUCTURED LIGHT AND CONTOURS

    Institute of Scientific and Technical Information of China (English)

    Jin Gang; Li Dehua; Hu Hanping; Hu Bing

    2002-01-01

    Three dimensional digitization of human head is desired in many applications. In this paper, an information fusion based scheme is presented to obtain 3-D information of human head. Structured light technology is employed to measure depth. For the special reflection areas,in which the structured light stripe can not be detected directly, the shape of the structured light stripe can be calculated from the corresponding contour. By fusing the information of structured light and the contours, the problem of reflectance influence is solved, and the whole shape of head,including hair area, can be obtained. Some good results are obtained.

  7. Beat-to-beat heart rate estimation fusing multimodal video and sensor data.

    Science.gov (United States)

    Antink, Christoph Hoog; Gao, Hanno; Brüser, Christoph; Leonhardt, Steffen

    2015-08-01

    Coverage and accuracy of unobtrusively measured biosignals are generally relatively low compared to clinical modalities. This can be improved by exploiting redundancies in multiple channels with methods of sensor fusion. In this paper, we demonstrate that two modalities, skin color variation and head motion, can be extracted from the video stream recorded with a webcam. Using a Bayesian approach, these signals are fused with a ballistocardiographic signal obtained from the seat of a chair with a mean absolute beat-to-beat estimation error below 25 milliseconds and an average coverage above 90% compared to an ECG reference.

  8. Development of a Parafin Wax deposition Unit for Fused Deposition Modelling (FDM)

    DEFF Research Database (Denmark)

    D'Angelo, Greta; Hansen, Hans Nørgaard; Pedersen, David Bue

    2014-01-01

    . This project illustrates the redesign of an extrusion unit for the deposition of paraffin wax in Fused Deposition Modelling (FDM) instead of the conventional polymeric materials. Among the benefits and brought by the use of paraffin wax in such system are: the possibility to make highly complex and precise...... parts to subsequently use in a Lost Wax Casting process, multi-material Additive Manufacturing and the use of wax as support material during the production of complicated parts. Moreover it is believed that including waxes among the materials usable in FDM would promote new ways of using and exploring...

  9. Analysis of cell performance and thermal regeneration of a lithium-tin cell having an immobilized fused-salt electrolyte

    Science.gov (United States)

    Cairns, E. J.; Shimotake, H.

    1969-01-01

    Cell performance and thermal regeneration of a thermally regenerative cell uses lithium and tin and a fused-salt electrolyte. The emf of the Li-Sn cell, as a function of cathode-alloy composition, is shown to resemble that of the Na-Bi cell.

  10. THE INFLUENCE OF PERIPHERAL NEUROPATHY AND PERIPHERAL VASCULAR DISEASE IN THE OUTCOME OF DIABETIC FOOT MANAGEMENT – A PROSPECTIVE STUDY

    Directory of Open Access Journals (Sweden)

    Sundar Prakash S, Krishnakumar, Chandra Prabha

    2015-04-01

    Full Text Available Objective: Peripheral neuropathy and Peripheral Vascular Disease are the risk factors for the development of diabetic foot. The aim of this study was to evaluate differences and predictors of outcome parameters in patients with diabetic foot by stratifying these subjects according to the severity of these risk factors. Materials and methods: This is a prospective study conducted in 70 patients in the age group of 30-90 years diagnosed as Type II Diabetes with foot ulcers. After detailed clinical examination the following tests were conducted in all the patients: Complete blood count (CBC, Haemoglobin (Hb, Random Blood Sugar (RBS, Erythrocyte Sedimentation rate (ESR, Chest X-ray(CXR, Electrocardiography (ECG, foot X-ray, pus culture, Neuropathy testing by Semmes Weinstein Monofilament Test and Vibration Perception Threshold and Peripheral vascularity assessment by Duplex Doppler. Then grading of the ulcers was done using Wagner’s Grade. The outcome of the patients was assessed by recording the healing time, mode of surgery and amputation rates of the patients. Results: A total of 70 patients with diabetic foot were consecutively included into the study (65.7% male, age (31% in 51-60 years, mean diabetes duration (5.2 years, Ulcer Grade (37% in Grade IV, Foot lesions (45.7% in toe, Blood sugar levels (64% in 300-400 mg/dl, Neuropathy (84%, Peripheral vascular disease (67%, major amputation (7% and mortality (1.4%. Conclusion: All diabetic patients should undergo testing for neuropathy and peripheral vascular disease apart from doing other tests.

  11. Fusing Quantitative Requirements Analysis with Model-based Systems Engineering

    Science.gov (United States)

    Cornford, Steven L.; Feather, Martin S.; Heron, Vance A.; Jenkins, J. Steven

    2006-01-01

    A vision is presented for fusing quantitative requirements analysis with model-based systems engineering. This vision draws upon and combines emergent themes in the engineering milieu. "Requirements engineering" provides means to explicitly represent requirements (both functional and non-functional) as constraints and preferences on acceptable solutions, and emphasizes early-lifecycle review, analysis and verification of design and development plans. "Design by shopping" emphasizes revealing the space of options available from which to choose (without presuming that all selection criteria have previously been elicited), and provides means to make understandable the range of choices and their ramifications. "Model-based engineering" emphasizes the goal of utilizing a formal representation of all aspects of system design, from development through operations, and provides powerful tool suites that support the practical application of these principles. A first step prototype towards this vision is described, embodying the key capabilities. Illustrations, implications, further challenges and opportunities are outlined.

  12. Diabetic peripheral neuropathy, is it an autoimmune disease?

    Science.gov (United States)

    Janahi, Noor M; Santos, Derek; Blyth, Christine; Bakhiet, Moiz; Ellis, Mairghread

    2015-11-01

    Autoimmunity has been identified in a significant number of neuropathies, such as, proximal neuropathies, and autonomic neuropathies associated with diabetes mellitus. However, possible correlations between diabetic peripheral neuropathy and autoimmunity have not yet been fully investigated. This study was conducted to investigate whether autoimmunity is associated with the pathogenesis of human diabetic peripheral neuropathy. A case-control analysis included three groups: 30 patients with diabetic peripheral neuropathy, 30 diabetic control patients without neuropathy, and 30 healthy controls. Blood analysis was conducted to compare the percentages of positive antinuclear antibodies (ANA) between the three groups. Secondary analysis investigated the correlations between the presence of autoimmune antibodies and sample demographics and neurological manifestations. This research was considered as a pilot study encouraging further investigations to take place in the near future. Antinuclear antibodies were significantly present in the blood serum of patients with diabetic peripheral neuropathy in comparison to the control groups (pneuropathy group were 50 times higher when compared to control groups. Secondary analysis showed a significant correlation between the presence of ANA and the neurological manifestation of neuropathy (Neuropathy symptom score, Neuropathy disability score and Vibration Perception Threshold). The study demonstrated for the first time that human peripheral diabetic neuropathy may have an autoimmune aetiology. The new pathogenic factors may lead to the consideration of new management plans involving new therapeutic approaches and disease markers. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Comprehensive management of presbycusis: central and peripheral.

    Science.gov (United States)

    Parham, Kourosh; Lin, Frank R; Coelho, Daniel H; Sataloff, Robert T; Gates, George A

    2013-04-01

    The prevailing otolaryngologic approach to treatment of age-related hearing loss (ARHL), presbycusis, emphasizes compensation of peripheral functional deficits (ie, hearing aids and cochlear implants). This approach does not address adequately the needs of the geriatric population, 1 in 5 of whom is expected to consist of the "old old" in the coming decades. Aging affects both the peripheral and central auditory systems, and disorders of executive function become more prevalent with advancing age. Growing evidence supports an association between age-related hearing loss and cognitive decline. Thus, to facilitate optimal functional capacity in our geriatric patients, a more comprehensive management strategy of ARHL is needed. Diagnostic evaluation should go beyond standard audiometric testing and include measures of central auditory function, including dichotic tasks and speech-in-noise testing. Treatment should include not only appropriate means of peripheral compensation but also auditory rehabilitative training and counseling.

  14. Contrast media and pain during peripheral arteriography

    International Nuclear Information System (INIS)

    Hagen, B.; Clauss, W.

    1982-01-01

    Some contrast media (CM) were for inducing pain and heat by an intraindividual comparison in 60 patients with occlusive peripheral arterial disease. A dolorimeter and calorimeter (graduated scales) were employed to register and differentiate the subjective sensations experienced by the patient, while objective reactions (peripheral motoric reactions, circulatory parameters) were recorded by the trialist at the same time. Ioxaglate, an ionic dimer, was distinctly superior to Ioglicinate, an ionic CM. However, the differences were less marked in the comparison with a Ioglicinate-Lidocaine-mixture. Emphasis is given to the fact osmolality is the most important parameter in the development of pain. Potential points at which the intraarterially administered local anaesthetic could attack are discussed. The clinical conclusions include consideration of the cost-effectivity ratios of the tested CM's and a discussion of whether or not modern stanards still justify general anaesthesia for peripheral angiography. (orig.)

  15. Ultrafast laser induced electronic and structural modifications in bulk fused silica

    Energy Technology Data Exchange (ETDEWEB)

    Mishchik, K.; D' Amico, C.; Velpula, P. K.; Mauclair, C.; Boukenter, A.; Ouerdane, Y.; Stoian, R. [Laboratoire Hubert Curien, UMR 5516 CNRS, Université de Lyon, Université Jean Monnet, 42000 Saint Etienne (France)

    2013-10-07

    Ultrashort laser pulses can modify the inner structure of fused silica, generating refractive index changes varying from soft positive (type I) light guiding forms to negative (type II) values with void presence and anisotropic sub-wavelength modulation. We investigate electronic and structural material changes in the type I to type II transition via coherent and incoherent secondary light emission reflecting free carrier behavior and post-irradiation material relaxation in the index change patterns. Using phase contrast microscopy, photoluminescence, and Raman spectroscopy, we determine in a space-resolved manner defect formation, redistribution and spatial segregation, and glass network reorganization paths in conditions marking the changeover between type I and type II photoinscription regimes. We first show characteristic patterns of second harmonic generation in type I and type II traces, indicating the collective involvement of free carriers and polarization memory. Second, incoherent photoemission from resonantly and non-resonantly excited defect states reveals accumulation of non-bridging oxygen hole centers (NBOHCs) in positive index domains and oxygen deficiency centers (ODCs) with O{sub 2}{sup −} ions segregation in void-like regions and in the nanostructured domains, reflecting the interaction strength. Complementary Raman investigations put into evidence signatures of the different environments where photo-chemical densification (bond rearrangements) and mechanical effects can be indicated. NBOHCs setting in before visible index changes serve as precursors for subsequent compaction build-up, indicating a scenario of cold, defect-assisted densification for the soft type I irradiation regime. Additionally, we observe hydrodynamic effects and severe bond-breaking in type II zones with indications of phase transition. These observations illuminate densification paths in fused silica in low power irradiation regimes, and equally in energetic ranges

  16. Quality assessment of online patient education resources for peripheral neuropathy.

    Science.gov (United States)

    Hansberry, David R; Suresh, Ragha; Agarwal, Nitin; Heary, Robert F; Goldstein, Ira M

    2013-03-01

    Given its practicality, the internet is a primary resource for patients afflicted with diseases like peripheral neuropathy. Therefore, it is important that the readily available online resources on peripheral neuropathy are tailored to the general public, particularly concerning readability. Patient education resources were downloaded from the US National Library of Medicine, Mayo Clinic, National Institute of Neurological Disorders and Stroke, Neuropathy.org, GBS/CIDP Foundation International, Hereditary Neuropathy Foundation, Charcot-Marie-Tooth Association, Foundation for Peripheral Neuropathy, and Neuropathy Action Foundation websites. All patient education material related to peripheral neuropathy was evaluated for its level of readability using the Flesch Reading Ease (FRE) and Flesch-Kincaid Grade Level. The FRE scores averaged 43.4 with only the US National Library of Medicine scoring above 60 (76.5). The Flesch-Kincaid Grade Level scores averaged 11.0. All scores were above a seventh-grade level except the US National Library of Medicine, which had a score of a fifth-grade reading level. Most Americans may not fully benefit from patient education resources concerning peripheral neuropathy education on many of the websites. Only the US National Library of Medicine, which is written at a fifth-grade level, is likely to benefit the average American. © 2013 Peripheral Nerve Society.

  17. Chemotherapy-induced peripheral neuropathy : Impact on quality of life

    NARCIS (Netherlands)

    Scheel, A.; Beijers, A.J.M.; Mols, F.; Faber, C.G.; Vreugdenhil, G.

    2014-01-01

    Peripheral neuropathy is a frequently occurring side-effect of chemotherapy as a cancer treatment. The incidence of chemotherapy-induced peripheral neuropathy (CIPN) is increasing as a consequence of better treatment of cancer becoming available and increasing use of chemotherapy, and because CIPN

  18. Optimization of Peripheral Finned-Tube Evaporators Using Entropy Generation Minimization

    OpenAIRE

    Pussoli, Bruno; Barbosa Jr., Jader; da Silva, Luciana; Kaviany, Massoud

    2012-01-01

    The peripheral finned-tube (PFT) is a new geometry for enhanced air-side heat transfer under moisture condensate blockage (evaporators). It consists of individual hexagonal (peripheral) fin arrangements with radial fins whose bases are attached to the tubes and tips are interconnected with the peripheral fins. In this paper, experimentally validated semi-empirical models for the air-side heat transfer and pressure drop are combined with the entropy generation minimization theory to determine ...

  19. File list: Unc.Bld.20.AllAg.Peripheral_blood [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Bld.20.AllAg.Peripheral_blood hg19 Unclassified Blood Peripheral blood SRX10800...66 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Unc.Bld.20.AllAg.Peripheral_blood.bed ...

  20. File list: Unc.Bld.50.AllAg.Peripheral_blood [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Bld.50.AllAg.Peripheral_blood hg19 Unclassified Blood Peripheral blood SRX10800...66 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Unc.Bld.50.AllAg.Peripheral_blood.bed ...

  1. Analysis of polycyclic aromatic hydrocarbons. I. Determination by gas chromatography with glass and fused solica capillary columns

    International Nuclear Information System (INIS)

    Perez Garcia, M.; Gonzalez, D.

    1987-01-01

    A study of the analysis by gas chromatography of aromatic polycyclic hydrocarbons is presented. The separation has been carried out by glass and fused silice capillary column. The limitations and the advantages of the procedure are discussed in terms of separation efficiency, sensitivity and precision. (author). 3 figs., 17 refs

  2. The comparison of CT findings between peripheral pulmonary squamous cell carcinoma and pulmonary adenocarcinoma

    International Nuclear Information System (INIS)

    Tan Guosheng; Yang Xufeng; Zhou Xuhui; Li Ziping; Fan Miao; Chen Jindi

    2007-01-01

    Objective: To compare the principal HRCT features of peripheral pulmonary squamous cell carcinoma and pulmonary adenocarcinoma and to explore their pathological mechanism, in order to improve the recognition of the CT signs of peripheral pulmonary carcinoma. Methods: The principal HRCT signs of thirty-five cases with pathologically proved peripheral pulmonary squamous cell carcinoma and forty cases with pathologically proved peripheral pulmonary adenocarcinoma were analyzed retrospectively to explore the relationship between CT features and pathological findings. Results: The main features of peripheral pulmonary squamous cell carcinoma included larger masses, clear boundary, superficial sublobes and intra-tumor necrosis. While peripheral pulmonary adenocarcinoma mostly demonstrated as smaller nodules, deep sublobes, spiculations, spiculate protuberance, pleural indentation, vessel converging signs, and vacuole signs. The different of these above findings of peripheral pulmonary squamous cell carcinoma and adenocarcinoma were significant (P<0.05). Peripheral pulmonary squamous cell carcinoma may depict bronchial casts and polygonal nodules; and peripheral pulmonary adenocarcinoma may demonstrate ground glass-like nodules. Conclusion: The difference of the CT findings between peripheral pulmonary squamous cell carcinoma and peripheral adenocarcinoma is based on their different histological features and biological behaviors. It is possible to differentiate them before operation in combination with clinical information. (authors)

  3. Autophagy meets fused in sarcoma-positive stress granules.

    Science.gov (United States)

    Matus, Soledad; Bosco, Daryl A; Hetz, Claudio

    2014-12-01

    Mutations in fused in sarcoma and/or translocated in liposarcoma (FUS, TLS or FUS) are linked to familial cases of amyotrophic lateral sclerosis (ALS). Mutant FUS selectively accumulates into discrete cytosolic structures known as stress granules under various stress conditions. In addition, mutant FUS expression can alter the dynamics and morphology of stress granules. Although the link between mutant FUS and stress granules is well established, the mechanisms modulating stress granule formation and disassembly in the context of ALS are poorly understood. In this issue of Neurobiology of Aging, Ryu et al. uncover the impact of autophagy on the potential toxicity of mutant FUS-positive stress granules. The authors provide evidence indicating that enhanced autophagy activity reduces the number of stress granules, which in the case of cells containing mutant FUS-positive stress granules, is neuroprotective. Overall, this study identifies an intersection between the proteostasis network and alterations in RNA metabolism in ALS through the dynamic assembly and disassembly of stress granules. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Fusing metabolomics data sets with heterogeneous measurement errors

    Science.gov (United States)

    Waaijenborg, Sandra; Korobko, Oksana; Willems van Dijk, Ko; Lips, Mirjam; Hankemeier, Thomas; Wilderjans, Tom F.; Smilde, Age K.

    2018-01-01

    Combining different metabolomics platforms can contribute significantly to the discovery of complementary processes expressed under different conditions. However, analysing the fused data might be hampered by the difference in their quality. In metabolomics data, one often observes that measurement errors increase with increasing measurement level and that different platforms have different measurement error variance. In this paper we compare three different approaches to correct for the measurement error heterogeneity, by transformation of the raw data, by weighted filtering before modelling and by a modelling approach using a weighted sum of residuals. For an illustration of these different approaches we analyse data from healthy obese and diabetic obese individuals, obtained from two metabolomics platforms. Concluding, the filtering and modelling approaches that both estimate a model of the measurement error did not outperform the data transformation approaches for this application. This is probably due to the limited difference in measurement error and the fact that estimation of measurement error models is unstable due to the small number of repeats available. A transformation of the data improves the classification of the two groups. PMID:29698490

  5. Statin use and peripheral sensory perception: a pilot study.

    Science.gov (United States)

    West, Brenton; Williams, Cylie M; Jilbert, Elise; James, Alicia M; Haines, Terry P

    2014-06-01

    Peripheral sensory neuropathy is a neurological deficit resulting in decreased detection of sensation through the peripheral nervous system. Peripheral sensory neuropathy is commonly diagnosed with the use of a monofilament and either a tuning fork or neurothesiometer. Statins are a widely used medication and there has been some debate of association with their use and peripheral sensory neuropathy. This pilot study aimed to test the sensory perception of participants with long-term statin use and compare these results to their peers who were not taking statins. Thirty participants were recruited and equally divided into a statin and non-statin group. Healthy participants were screened by their medical and medication history, Australian Type 2 Diabetes Risk assessment, and random blood glucose level. An assessor who was blinded to the participant group conducted sensory assessments using a 10 g monofilament and neurothesiometer. There was no difference in monofilament testing results between the groups. The statin group was less sensate at the styloid process (p = 0.031) and medial malleolus (p = 0.003) than the control group. Results at the hallux were not statistically significant (p = 0.183). This result is suggestive of a potential association between long-term statin use and a decrease in peripheral sensory perception. This may be because of peripheral sensory neuropathy. Limitations such as consideration of participant height, participant numbers, and inability to analyze results against statin groups are reported. As statins are a life-saving medication, careful consideration should be applied to these results and further research be conducted to determine if these results are applicable to larger populations.

  6. Electrophysiological measurements of diabetic peripheral neuropathy: A systematic review.

    Science.gov (United States)

    Shabeeb, Dheyauldeen; Najafi, Masoud; Hasanzadeh, Gholamreza; Hadian, Mohammed Reza; Musa, Ahmed Eleojio; Shirazi, Alireza

    2018-03-28

    Peripheral neuropathy is one of the main complications of diabetes mellitus. One of the features of diabetic nerve damage is abnormality of sensory and motor nerve conduction study. An electrophysiological examination can be reproduced and is also a non-invasive approach in the assessment of peripheral nerve function. Population-based and clinical studies have been conducted to validate the sensitivity of these methods. When the diagnosis was based on clinical electrophysiological examination, abnormalities were observed in all patients. In this research, using a review design, we reviewed the issue of clinical electrophysiological examination of diabetic peripheral neuropathy in articles from 2008 to 2017. For this purpose, PubMed, Scopus and Embase databases of journals were used for searching articles. The researchers indicated that diabetes (both types) is a very disturbing health issue in the modern world and should be given serious attention. Based on conducted studies, it was demonstrated that there are different procedures for prevention and treatment of diabetes-related health problems such as diabetic polyneuropathy (DPN). The first objective quantitative indication of the peripheral neuropathy is abnormality of sensory and motor nerve conduction tests. Electrophysiology is accurate, reliable and sensitive. It can be reproduced and also is a noninvasive approach in the assessment of peripheral nerve function. The methodological review has found that the best method for quantitative indication of the peripheral neuropathy compared with all other methods is clinical electrophysiological examination. For best results, standard protocols such as temperature control and equipment calibration are recommended. Copyright © 2018. Published by Elsevier Ltd.

  7. Nanoimprint Lithography on curved surfaces prepared by fused deposition modelling

    International Nuclear Information System (INIS)

    Köpplmayr, Thomas; Häusler, Lukas; Bergmair, Iris; Mühlberger, Michael

    2015-01-01

    Fused deposition modelling (FDM) is an additive manufacturing technology commonly used for modelling, prototyping and production applications. The achievable surface roughness is one of its most limiting aspects. It is however of great interest to create well-defined (nanosized) patterns on the surface for functional applications such as optical effects, electronics or bio-medical devices. We used UV-curable polymers of different viscosities and flexible stamps made of poly(dimethylsiloxane) (PDMS) to perform Nanoimprint Lithography (NIL) on FDM-printed curved parts. Substrates with different roughness and curvature were prepared using a commercially available 3D printer. The nanoimprint results were characterized by optical light microscopy, profilometry and atomic force microscopy (AFM). Our experiments show promising results in creating well-defined microstructures on the 3D-printed parts. (paper)

  8. Regional crop gross primary production and yield estimation using fused Landsat-MODIS data

    Science.gov (United States)

    He, M.; Kimball, J. S.; Maneta, M. P.; Maxwell, B. D.; Moreno, A.

    2017-12-01

    Accurate crop yield assessments using satellite-based remote sensing are of interest for the design of regional policies that promote agricultural resiliency and food security. However, the application of current vegetation productivity algorithms derived from global satellite observations are generally too coarse to capture cropland heterogeneity. Merging information from sensors with reciprocal spatial and temporal resolution can improve the accuracy of these retrievals. In this study, we estimate annual crop yields for seven important crop types -alfalfa, barley, corn, durum wheat, peas, spring wheat and winter wheat over Montana, United States (U.S.) from 2008 to 2015. Yields are estimated as the product of gross primary production (GPP) and a crop-specific harvest index (HI) at 30 m spatial resolution. To calculate GPP we used a modified form of the MOD17 LUE algorithm driven by a 30 m 8-day fused NDVI dataset constructed by blending Landsat (5 or 7) and MODIS Terra reflectance data. The fused 30-m NDVI record shows good consistency with the original Landsat and MODIS data, but provides better spatiotemporal information on cropland vegetation growth. The resulting GPP estimates capture characteristic cropland patterns and seasonal variations, while the estimated annual 30 m crop yield results correspond favorably with county-level crop yield data (r=0.96, pcrop yield performance was generally lower, but still favorable in relation to field-scale crop yield surveys (r=0.42, p<0.01). Our methods and results are suitable for operational applications at regional scales.

  9. Silica sulfuric acid: a reusable solid catalyst for one pot synthesis of densely substituted pyrrole-fused isocoumarins under solvent-free conditions

    Directory of Open Access Journals (Sweden)

    Sudipta Pathak

    2013-11-01

    Full Text Available A convenient and efficient methodology for the synthesis of densely substituted pyrrole-fused isocoumarins, which employs solid-supported silica sulfuric acid (SSA as catalyst, has been developed. When the mixture of ninhydrin adducts of acetylacetone/ethyl acetoacetate and primary amines was heated on the solid surface of SSA under solvent-free conditions, the pyrrole-fused isocoumarins were formed in good yields. This synthetic method has several advantages such as the employment of solvent-free reaction conditions without the use of any toxic reagents and metal catalysts, the ease of product isolation, the use of a recyclable catalyst, the low cost, the easy availability of the starting materials, and the excellent yields of products.

  10. Peripheral blood volume influenced by various external factors

    Energy Technology Data Exchange (ETDEWEB)

    Ittner, A; Scheibe, J; Stoll, W [Friedrich-Schiller-Universitaet, Jena (German Democratic Republic). Bereich Medizin

    1982-01-01

    The dependence of the peripheral blood volume upon various exogenous factors was studied in male sports students using /sup 113m/InCl. The results obtained revealed that whole-body exertions and local muscular activity produce an increase of the blood volume in the lower extremities associated with increased blood circulation. The passive measures applied caused also an increase of the blood volume, but not in all of the subjects examined. Isometric concentrations led to a highly significant reduction of the peripheral blood volume. The scintigraphic method for the visualization of the blood volume in peripheral regions of the body can be regarded as suitable for the study of hemodynamics and for the substantiation of the efficiency of measures promoting restoration.

  11. Network node for peripheral sharing

    International Nuclear Information System (INIS)

    Bobbitt, J.; Johnson, M.

    1977-01-01

    A module which enables several independent computer systems to share the peripherals (graphics display and line printer) of a PDP-11 computer is described. The module requires no software support in the PDP-11

  12. File list: Unc.Bld.10.AllAg.Peripheral_blood [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Bld.10.AllAg.Peripheral_blood hg19 Unclassified Blood Peripheral blood SRX10800...66,SRX1080067 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Unc.Bld.10.AllAg.Peripheral_blood.bed ...

  13. File list: Unc.Bld.05.AllAg.Peripheral_blood [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Unc.Bld.05.AllAg.Peripheral_blood hg19 Unclassified Blood Peripheral blood SRX10800...66,SRX1080067 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Unc.Bld.05.AllAg.Peripheral_blood.bed ...

  14. [Clinical Trial to Test the iFuse Implant System® in Patients with Sacroiliac Joint Syndrome: One Year Results].

    Science.gov (United States)

    Bornemann, R; Pflugmacher, R; Webler, M; Koch, E M W; Dengler, J; Wirtz, D C; Frey, S P

    2016-12-01

    Background: This study reports one year post-operative monitoring of the efficacy and safety of iFuse Implant System® in patients with sacroiliac joint syndrome. Material and Methods: After 6 months of inadequate conservative treatment, patients with properly proven ISG syndrome were selected for surgery. The iFuse implants had a triangular profile and coating of porous titanium plasma spray and were used in the minimally invasive procedures. The procedure was performed under general anaesthesia and fluoroscopic control. In each case, three implants were placed. Results: 24 patients (22 f; 92 %; 54.9 ± 14 years) participated in the study. The operations were performed in 11 patients (46 %) on the left and in 13 patients (54 %) on the right. The mean operative time was 42.4 minutes (95 % CI: 35.6-49.3). The reduction in pain intensity on the VAS scale was 58 ± 11 mm (68 ± 7 %). The Oswestry score showed a median decrease of 44 percentage points (57 %). After 12 months, 15 patients (63 %) reported that they were taking no more painkillers. Conclusion: The minimally invasive treatment of patients with sacroiliac joint syndrome using the iFuse Implant System leads to significant analgesic effects over the period of one year; it also contributes significantly to improving the functioning of the patient. Georg Thieme Verlag KG Stuttgart · New York.

  15. Synthesis of benzo-fused 1-azabicyclo[m.n.0]alkanes via the Schmidt reaction: a formal synthesis of gephyrotoxin.

    Science.gov (United States)

    Pearson, W H; Fang, W

    2000-10-20

    The intramolecular capture of benzocyclobutyl, benzocyclopentyl, and benzocyclohexyl carbocations 7 by azides produces spirocyclic aminodiazonium ions 8, which undergo 1,2-C-to-N rearrangement with loss of dinitrogen to produce benzo-fused iminium ions resulting from either aryl (9) or alkyl (10) migration to the electron-deficient nitrogen atom. Reduction of the iminium ions affords regioisomeric benzo-fused 1-azabicyclo[m.n.0]alkanes, e.g., benzopyrrolizidines, benzoindolizidines, benzoquinolizidines, or perhydrobenzo[f]pyrrolo[1,2-a]azepines in two regioisomeric versions, anilines (e.g., 11-14) and benzylic amines (e.g., 15-18), the result of aryl and alkyl migrations, respectively. Generally, aryl migration is preferred, despite modeling that shows that the lowest energy aminodiazonium ions are those where the departing dinitrogen is preferentially antiperiplanar to the migrating alkyl group rather than the aryl group. The utility of this methodology was illustrated by a formal synthesis of the alkaloid gephyrotoxin 4. A dependence on the efficiency and regioselectivity of the Schmidt reaction upon subtle changes in the structure of the cation precursor was observed, necessitating the exploration of a variety of substrates. Fortunately, these materials were easily made. Ultimately, the azido-alkene 81 bearing a 2-bromoethyl side-chain was useful for the Schmidt reaction, producing the known benzo-fused indolizidine 49, which had been transformed by Ito et al. into gephyrotoxin 4. The synthesis of 49 required nine steps (five purifications) from commercially available 4-methoxy-1-indanone 60 and proceeded in 22% overall yield.

  16. Peripheral arterial disease and revascularization of the diabetic foot.

    Science.gov (United States)

    Forsythe, R O; Brownrigg, J; Hinchliffe, R J

    2015-05-01

    Diabetes is a complex disease with many serious potential sequelae, including large vessel arterial disease and microvascular dysfunction. Peripheral arterial disease is a common large vessel complication of diabetes, implicated in the development of tissue loss in up to half of patients with diabetic foot ulceration. In addition to peripheral arterial disease, functional changes in the microcirculation also contribute to the development of a diabetic foot ulcer, along with other factors such as infection, oedema and abnormal biomechanical loading. Peripheral arterial disease typically affects the distal vessels, resulting in multi-level occlusions and diffuse disease, which often necessitates challenging distal revascularisation surgery or angioplasty in order to improve blood flow. However, technically successful revascularisation does not always result in wound healing. The confounding effects of microvascular dysfunction must be recognised--treatment of a patient with a diabetic foot ulcer and peripheral arterial disease should address this complex interplay of pathophysiological changes. In the case of non-revascularisable peripheral arterial disease or poor response to conventional treatment, alternative approaches such as cell-based treatment, hyperbaric oxygen therapy and the use of vasodilators may appear attractive, however more robust evidence is required to justify these novel approaches. © 2014 John Wiley & Sons Ltd.

  17. Anterior cervical discectomy with fusion in patients with cervical disc degeneration: a prospective outcome study of 258 patients (181 fused with autologous bone graft and 77 fused with a PEEK cage)

    Science.gov (United States)

    2010-01-01

    Background Anterior cervical discectomy with fusion (ACDF) is challenging with respect to both patient selection and choice of surgical procedure. The aim of this study was to evaluate the clinical outcome of ACDF, with respect to both patient selection and choice of surgical procedure: fusion with an autologous iliac crest graft (AICG) versus fusion with an artificial cage made of polyetheretherketone (PEEK). Methods This was a non-randomized prospective single-center outcome study of 258 patients who underwent ACDF for cervical disc degeneration (CDD). Fusion was attained with either tricortical AICG or PEEK cages without additional anterior plating, with treatment selected at surgeon's discretion. Radicular pain, neck-pain, headache and patient satisfaction with the treatment were scored using the visual analogue scale (VAS). Results The median age was 47.5 (28.3-82.8) years, and 44% of patients were female. 59% had single-level ACDF, 40% had two level ACDF and 1% had three-level ACDF. Of the patients, 181 were fused with AICG and 77 with a PEEK-cage. After surgery, the patients showed a significant reduction in radicular pain (ΔVAS = 3.05), neck pain (ΔVAS = 2.30) and headache (ΔVAS = 0.55). Six months after surgery, 48% of patients had returned to work: however 24% were still receiving workers' compensation. Using univariate and multivariate analyses we found that high preoperative pain intensity was significantly associated with a decrease in pain intensity after surgery, for all three pain categories. There were no significant correlations between pain relief and the following patient characteristics: fusion method (AICG or PEEK-cage), sex, age, number of levels fused, disc level fused, previous neck surgery (except for neck pain), previous neck trauma, or preoperative symptom duration. Two hundred out of the 256 (78%) patients evaluated the surgical result as successful. Only 27/256 (11%) classified the surgical result as a failure. Patient satisfaction

  18. Anterior cervical discectomy with fusion in patients with cervical disc degeneration: a prospective outcome study of 258 patients (181 fused with autologous bone graft and 77 fused with a PEEK cage

    Directory of Open Access Journals (Sweden)

    Roenning Paal

    2010-03-01

    Full Text Available Abstract Background Anterior cervical discectomy with fusion (ACDF is challenging with respect to both patient selection and choice of surgical procedure. The aim of this study was to evaluate the clinical outcome of ACDF, with respect to both patient selection and choice of surgical procedure: fusion with an autologous iliac crest graft (AICG versus fusion with an artificial cage made of polyetheretherketone (PEEK. Methods This was a non-randomized prospective single-center outcome study of 258 patients who underwent ACDF for cervical disc degeneration (CDD. Fusion was attained with either tricortical AICG or PEEK cages without additional anterior plating, with treatment selected at surgeon's discretion. Radicular pain, neck-pain, headache and patient satisfaction with the treatment were scored using the visual analogue scale (VAS. Results The median age was 47.5 (28.3-82.8 years, and 44% of patients were female. 59% had single-level ACDF, 40% had two level ACDF and 1% had three-level ACDF. Of the patients, 181 were fused with AICG and 77 with a PEEK-cage. After surgery, the patients showed a significant reduction in radicular pain (ΔVAS = 3.05, neck pain (ΔVAS = 2.30 and headache (ΔVAS = 0.55. Six months after surgery, 48% of patients had returned to work: however 24% were still receiving workers' compensation. Using univariate and multivariate analyses we found that high preoperative pain intensity was significantly associated with a decrease in pain intensity after surgery, for all three pain categories. There were no significant correlations between pain relief and the following patient characteristics: fusion method (AICG or PEEK-cage, sex, age, number of levels fused, disc level fused, previous neck surgery (except for neck pain, previous neck trauma, or preoperative symptom duration. Two hundred out of the 256 (78% patients evaluated the surgical result as successful. Only 27/256 (11% classified the surgical result as a failure

  19. Peripheral changes in endometriosis-associated pain

    Science.gov (United States)

    Morotti, Matteo; Vincent, Katy; Brawn, Jennifer; Zondervan, Krina T.; Becker, Christian M.

    2014-01-01

    BACKGROUND Pain remains the cardinal symptom of endometriosis. However, to date, the underlying mechanisms are still only poorly understood. Increasing evidence points towards a close interaction between peripheral nerves, the peritoneal environment and the central nervous system in pain generation and processing. Recently, studies demonstrating nerve fibres and neurotrophic and angiogenic factors in endometriotic lesions and their vicinity have led to increased interest in peripheral changes in endometriosis-associated pain. This review focuses on the origin and function of these nerves and factors as well as possible peripheral mechanisms that may contribute to the generation and modulation of pain in women with endometriosis. METHODS We conducted a systematic search using several databases (PubMed, MEDLINE, EMBASE and CINAHL) of publications from January 1977 to October 2013 to evaluate the possible roles of the peripheral nervous system in endometriosis pathophysiology and how it can contribute to endometriosis-associated pain. RESULTS Endometriotic lesions and peritoneal fluid from women with endometriosis had pronounced neuroangiogenic properties with increased expression of new nerve fibres, a shift in the distribution of sensory and autonomic fibres in some locations, and up-regulation of several neurotrophins. In women suffering from deep infiltrating endometriosis and bowel endometriosis, in which the anatomical distribution of lesions is generally more closely related to pelvic pain symptoms, endometriotic lesions and surrounding tissues present higher nerve fibre densities compared to peritoneal lesions and endometriomas. More data are needed to fully confirm a direct correlation between fibre density in these locations and the amount of perceived pain. A better correlation between the presence of nerve fibres and pain symptoms seems to exist for eutopic endometrium. However, this appears not to be exclusive to endometriosis. No correlation between

  20. Auditory attention activates peripheral visual cortex.

    Directory of Open Access Journals (Sweden)

    Anthony D Cate

    Full Text Available BACKGROUND: Recent neuroimaging studies have revealed that putatively unimodal regions of visual cortex can be activated during auditory tasks in sighted as well as in blind subjects. However, the task determinants and functional significance of auditory occipital activations (AOAs remains unclear. METHODOLOGY/PRINCIPAL FINDINGS: We examined AOAs in an intermodal selective attention task to distinguish whether they were stimulus-bound or recruited by higher-level cognitive operations associated with auditory attention. Cortical surface mapping showed that auditory occipital activations were localized to retinotopic visual cortex subserving the far peripheral visual field. AOAs depended strictly on the sustained engagement of auditory attention and were enhanced in more difficult listening conditions. In contrast, unattended sounds produced no AOAs regardless of their intensity, spatial location, or frequency. CONCLUSIONS/SIGNIFICANCE: Auditory attention, but not passive exposure to sounds, routinely activated peripheral regions of visual cortex when subjects attended to sound sources outside the visual field. Functional connections between auditory cortex and visual cortex subserving the peripheral visual field appear to underlie the generation of AOAs, which may reflect the priming of visual regions to process soon-to-appear objects associated with unseen sound sources.