WorldWideScience

Sample records for peripheral visual detection

  1. Emotional facial expression detection in the peripheral visual field.

    Directory of Open Access Journals (Sweden)

    Dimitri J Bayle

    Full Text Available BACKGROUND: In everyday life, signals of danger, such as aversive facial expressions, usually appear in the peripheral visual field. Although facial expression processing in central vision has been extensively studied, this processing in peripheral vision has been poorly studied. METHODOLOGY/PRINCIPAL FINDINGS: Using behavioral measures, we explored the human ability to detect fear and disgust vs. neutral expressions and compared it to the ability to discriminate between genders at eccentricities up to 40°. Responses were faster for the detection of emotion compared to gender. Emotion was detected from fearful faces up to 40° of eccentricity. CONCLUSIONS: Our results demonstrate the human ability to detect facial expressions presented in the far periphery up to 40° of eccentricity. The increasing advantage of emotion compared to gender processing with increasing eccentricity might reflect a major implication of the magnocellular visual pathway in facial expression processing. This advantage may suggest that emotion detection, relative to gender identification, is less impacted by visual acuity and within-face crowding in the periphery. These results are consistent with specific and automatic processing of danger-related information, which may drive attention to those messages and allow for a fast behavioral reaction.

  2. Peripheral visual performance enhancement by neurofeedback training.

    Science.gov (United States)

    Nan, Wenya; Wan, Feng; Lou, Chin Ian; Vai, Mang I; Rosa, Agostinho

    2013-12-01

    Peripheral visual performance is an important ability for everyone, and a positive inter-individual correlation is found between the peripheral visual performance and the alpha amplitude during the performance test. This study investigated the effect of alpha neurofeedback training on the peripheral visual performance. A neurofeedback group of 13 subjects finished 20 sessions of alpha enhancement feedback within 20 days. The peripheral visual performance was assessed by a new dynamic peripheral visual test on the first and last training day. The results revealed that the neurofeedback group showed significant enhancement of the peripheral visual performance as well as the relative alpha amplitude during the peripheral visual test. It was not the case in the non-neurofeedback control group, which performed the tests within the same time frame as the neurofeedback group but without any training sessions. These findings suggest that alpha neurofeedback training was effective in improving peripheral visual performance. To the best of our knowledge, this is the first study to show evidence for performance improvement in peripheral vision via alpha neurofeedback training.

  3. Effects of visual attention on chromatic and achromatic detection sensitivities.

    Science.gov (United States)

    Uchikawa, Keiji; Sato, Masayuki; Kuwamura, Keiko

    2014-05-01

    Visual attention has a significant effect on various visual functions, such as response time, detection and discrimination sensitivity, and color appearance. It has been suggested that visual attention may affect visual functions in the early visual pathways. In this study we examined selective effects of visual attention on sensitivities of the chromatic and achromatic pathways to clarify whether visual attention modifies responses in the early visual system. We used a dual task paradigm in which the observer detected a peripheral test stimulus presented at 4 deg eccentricities while the observer concurrently carried out an attention task in the central visual field. In experiment 1, it was confirmed that peripheral spectral sensitivities were reduced more for short and long wavelengths than for middle wavelengths with the central attention task so that the spectral sensitivity function changed its shape by visual attention. This indicated that visual attention affected the chromatic response more strongly than the achromatic response. In experiment 2 it was obtained that the detection thresholds increased in greater degrees in the red-green and yellow-blue chromatic directions than in the white-black achromatic direction in the dual task condition. In experiment 3 we showed that the peripheral threshold elevations depended on the combination of color-directions of the central and peripheral stimuli. Since the chromatic and achromatic responses were separately processed in the early visual pathways, the present results provided additional evidence that visual attention affects responses in the early visual pathways.

  4. Auditory attention activates peripheral visual cortex.

    Directory of Open Access Journals (Sweden)

    Anthony D Cate

    Full Text Available BACKGROUND: Recent neuroimaging studies have revealed that putatively unimodal regions of visual cortex can be activated during auditory tasks in sighted as well as in blind subjects. However, the task determinants and functional significance of auditory occipital activations (AOAs remains unclear. METHODOLOGY/PRINCIPAL FINDINGS: We examined AOAs in an intermodal selective attention task to distinguish whether they were stimulus-bound or recruited by higher-level cognitive operations associated with auditory attention. Cortical surface mapping showed that auditory occipital activations were localized to retinotopic visual cortex subserving the far peripheral visual field. AOAs depended strictly on the sustained engagement of auditory attention and were enhanced in more difficult listening conditions. In contrast, unattended sounds produced no AOAs regardless of their intensity, spatial location, or frequency. CONCLUSIONS/SIGNIFICANCE: Auditory attention, but not passive exposure to sounds, routinely activated peripheral regions of visual cortex when subjects attended to sound sources outside the visual field. Functional connections between auditory cortex and visual cortex subserving the peripheral visual field appear to underlie the generation of AOAs, which may reflect the priming of visual regions to process soon-to-appear objects associated with unseen sound sources.

  5. Peripheral visual response time and visual display layout

    Science.gov (United States)

    Haines, R. F.

    1974-01-01

    Experiments were performed on a group of 42 subjects in a study of their peripheral visual response time to visual signals under positive acceleration, during prolonged bedrest, at passive 70 deg headup body lift, under exposures to high air temperatures and high luminance levels, and under normal stress-free laboratory conditions. Diagrams are plotted for mean response times to white, red, yellow, green, and blue stimuli under different conditions.

  6. Peripheral vision of youths with low vision: motion perception, crowding, and visual search.

    Science.gov (United States)

    Tadin, Duje; Nyquist, Jeffrey B; Lusk, Kelly E; Corn, Anne L; Lappin, Joseph S

    2012-08-24

    Effects of low vision on peripheral visual function are poorly understood, especially in children whose visual skills are still developing. The aim of this study was to measure both central and peripheral visual functions in youths with typical and low vision. Of specific interest was the extent to which measures of foveal function predict performance of peripheral tasks. We assessed central and peripheral visual functions in youths with typical vision (n = 7, ages 10-17) and low vision (n = 24, ages 9-18). Experimental measures used both static and moving stimuli and included visual crowding, visual search, motion acuity, motion direction discrimination, and multitarget motion comparison. In most tasks, visual function was impaired in youths with low vision. Substantial differences, however, were found both between participant groups and, importantly, across different tasks within participant groups. Foveal visual acuity was a modest predictor of peripheral form vision and motion sensitivity in either the central or peripheral field. Despite exhibiting normal motion discriminations in fovea, motion sensitivity of youths with low vision deteriorated in the periphery. This contrasted with typically sighted participants, who showed improved motion sensitivity with increasing eccentricity. Visual search was greatly impaired in youths with low vision. Our results reveal a complex pattern of visual deficits in peripheral vision and indicate a significant role of attentional mechanisms in observed impairments. These deficits were not adequately captured by measures of foveal function, arguing for the importance of independently assessing peripheral visual function.

  7. A new dynamic visual acuity test to assess peripheral vestibular function.

    Science.gov (United States)

    Vital, Domenic; Hegemann, Stefan C A; Straumann, Dominik; Bergamin, Oliver; Bockisch, Christopher J; Angehrn, Dominik; Schmitt, Kai-Uwe; Probst, Rudolf

    2010-07-01

    To evaluate a novel test for dynamic visual acuity (DVA) that uses an adaptive algorithm for changing the size of Landolt rings presented during active or passive head impulses, and to compare the results with search-coil head impulse testing. Prospective study in healthy individuals and patients with peripheral vestibular deficits. Tertiary academic center. One hundred neuro-otologically healthy individuals (age range, 19-80 years) and 15 patients with bilateral (n = 5) or unilateral (n = 10) peripheral vestibular loss (age range, 27-72 years). Testing of static visual acuity (SVA), DVA during active and passive horizontal head rotations (optotype presentation at head velocities >100 degrees/s and >150 degrees/s), and quantitative horizontal head impulse testing with scleral search coils. Difference between SVA and DVA, that is, visual acuity loss (VA loss), gain of the high-acceleration vestibulo-ocular reflex. Passive head impulses and higher velocities were more effective than active impulses and lower velocities. Using passive head impulses and velocities higher than 150 degrees/s, the DVA test discriminated significantly (P test sensitivity was 100%, specificity was 94%, and accuracy was 95%, with search-coil head impulse testing used as a reference. In healthy individuals, VA loss increased significantly with age (P testing with Landolt rings that are adaptively changed in size enables detection of peripheral vestibular dysfunction in a fast and simple way.

  8. Peripheral Vision of Youths with Low Vision: Motion Perception, Crowding, and Visual Search

    Science.gov (United States)

    Tadin, Duje; Nyquist, Jeffrey B.; Lusk, Kelly E.; Corn, Anne L.; Lappin, Joseph S.

    2012-01-01

    Purpose. Effects of low vision on peripheral visual function are poorly understood, especially in children whose visual skills are still developing. The aim of this study was to measure both central and peripheral visual functions in youths with typical and low vision. Of specific interest was the extent to which measures of foveal function predict performance of peripheral tasks. Methods. We assessed central and peripheral visual functions in youths with typical vision (n = 7, ages 10–17) and low vision (n = 24, ages 9–18). Experimental measures used both static and moving stimuli and included visual crowding, visual search, motion acuity, motion direction discrimination, and multitarget motion comparison. Results. In most tasks, visual function was impaired in youths with low vision. Substantial differences, however, were found both between participant groups and, importantly, across different tasks within participant groups. Foveal visual acuity was a modest predictor of peripheral form vision and motion sensitivity in either the central or peripheral field. Despite exhibiting normal motion discriminations in fovea, motion sensitivity of youths with low vision deteriorated in the periphery. This contrasted with typically sighted participants, who showed improved motion sensitivity with increasing eccentricity. Visual search was greatly impaired in youths with low vision. Conclusions. Our results reveal a complex pattern of visual deficits in peripheral vision and indicate a significant role of attentional mechanisms in observed impairments. These deficits were not adequately captured by measures of foveal function, arguing for the importance of independently assessing peripheral visual function. PMID:22836766

  9. The risk of pedestrian collisions with peripheral visual field loss.

    Science.gov (United States)

    Peli, Eli; Apfelbaum, Henry; Berson, Eliot L; Goldstein, Robert B

    2016-12-01

    Patients with peripheral field loss complain of colliding with other pedestrians in open-space environments such as shopping malls. Field expansion devices (e.g., prisms) can create artificial peripheral islands of vision. We investigated the visual angle at which these islands can be most effective for avoiding pedestrian collisions, by modeling the collision risk density as a function of bearing angle of pedestrians relative to the patient. Pedestrians at all possible locations were assumed to be moving in all directions with equal probability within a reasonable range of walking speeds. The risk density was found to be highly anisotropic. It peaked at ≈45° eccentricity. Increasing pedestrian speed range shifted the risk to higher eccentricities. The risk density is independent of time to collision. The model results were compared to the binocular residual peripheral island locations of 42 patients with forms of retinitis pigmentosa. The natural residual island prevalence also peaked nasally at about 45° but temporally at about 75°. This asymmetry resulted in a complementary coverage of the binocular field of view. Natural residual binocular island eccentricities seem well matched to the collision-risk density function, optimizing detection of other walking pedestrians (nasally) and of faster hazards (temporally). Field expansion prism devices will be most effective if they can create artificial peripheral islands at about 45° eccentricities. The collision risk and residual island findings raise interesting questions about normal visual development.

  10. Long-Term Visual Prognosis of Peripheral Multifocal Chorioretinitis

    NARCIS (Netherlands)

    Ossewaarde-van Norel, J; ten Dam-van Loon, NH; de Boer, JH; Rothova, A.

    2015-01-01

    Purpose To report on the clinical manifestations, complications, and long-term visual prognosis of patients with peripheral multifocal chorioretinitis and to search for predictors for a lower visual outcome. Design Retrospective consecutive observational case series. Methods setting: Institutional.

  11. Is theta burst stimulation applied to visual cortex able to modulate peripheral visual acuity?

    Directory of Open Access Journals (Sweden)

    Sabrina Brückner

    Full Text Available Repetitive transcranial magnetic stimulation is usually applied to visual cortex to explore the effects on cortical excitability. Most researchers therefore concentrate on changes of phosphene threshold, rarely on consequences for visual performance. Thus, we investigated peripheral visual acuity in the four quadrants of the visual field using Landolt C optotypes before and after repetitive stimulation of the visual cortex. We applied continuous and intermittend theta burst stimulation with various stimulation intensities (60%, 80%, 100%, 120% of individual phosphene threshold as well as monophasic and biphasic 1 Hz stimulation, respectively. As an important result, no serious adverse effects were observed. In particular, no seizure was induced, even with theta burst stimulation applied with 120% of individual phosphene threshold. In only one case stimulation was ceased because the subject reported intolerable pain. Baseline visual acuity decreased over sessions, indicating a continuous training effect. Unexpectedly, none of the applied transcranial magnetic stimulation protocols had an effect on performance: no change in visual acuity was found in any of the four quadrants of the visual field. Binocular viewing as well as the use of peripheral instead of foveal presentation of the stimuli might have contributed to this result. Furthermore, intraindividual variability could have masked the TMS- induced effects on visual acuity.

  12. Auditory and visual reaction time and peripheral field of vision in helmet users

    Directory of Open Access Journals (Sweden)

    Abbupillai Adhilakshmi

    2016-12-01

    Full Text Available Background: The incidence of fatal accidents are more in two wheeler drivers compared to four wheeler drivers. Head injury is of serious concern when recovery and prognosis of the patients are warranted, helmets are being used for safety purposes by moped, scooters and motorcycle drivers. Although, helmets are designed with cushioning effect to prevent head injuries but there are evidences of increase risk of neck injuries and reduced peripheral vision and hearing in helmet users. A complete full coverage helmets provide about less than 3 percent restrictions in horizontal peripheral visual field compared to rider without helmet. The standard company patented ergonomically designed helmets which does not affect the peripheral vision neither auditory reaction time. Objective: This pilot study aimed to evaluate the peripheral field of vision and auditory and visual reaction time in a hypertensive, diabetic and healthy male and female in order to have a better insight of protective characteristics of helmet in health and disease. Method: This pilot study carried out on age matched male of one healthy, one hypertensive and one diabetic and female subject of one healthy, one hypertensive and one diabetics. The field of vision was assessed by Lister’s perimeter whereas auditory and visual reaction time was recorded with response analyser. Result : Gender difference was not noted in peripheral field of vision but mild difference was found in auditory reaction time for high frequency and visual reaction time for both red and green colour in healthy control. But lateral and downward peripheral visual field was found reduced whereas auditory and visual reaction time was found increased in both hypertensive and diabetic subject in both sexes. Conclusion: Peripheral vision, auditory reaction time and visual reaction time in hypertensive and diabetics may lead to vulnerable accident. Helmet use has proven to reduce extent of injury in motorcyclist and

  13. Enhanced peripheral visual processing in congenitally deaf humans is supported by multiple brain regions, including primary auditory cortex

    Directory of Open Access Journals (Sweden)

    Gregory D. Scott

    2014-03-01

    Full Text Available Brain reorganization associated with altered sensory experience clarifies the critical role of neuroplasticity in development. An example is enhanced peripheral visual processing associated with congenital deafness, but the neural systems supporting this have not been fully characterized. A gap in our understanding of deafness-enhanced peripheral vision is the contribution of primary auditory cortex. Previous studies of auditory cortex that use anatomical normalization across participants were limited by inter-subject variability of Heschl’s gyrus. In addition to reorganized auditory cortex (cross-modal plasticity, a second gap in our understanding is the contribution of altered modality-specific cortices (visual intramodal plasticity in this case, as well as supramodal and multisensory cortices, especially when target detection is required across contrasts. Here we address these gaps by comparing fMRI signal change for peripheral versus perifoveal visual stimulation (11-15° vs. 2°-7° in congenitally deaf and hearing participants in a blocked experimental design with two analytical approaches: a Heschl’s gyrus region of interest analysis and a whole brain analysis. Our results using individually-defined primary auditory cortex (Heschl’s gyrus indicate that fMRI signal change for more peripheral stimuli was greater than perifoveal in deaf but not in hearing participants. Whole-brain analyses revealed differences between deaf and hearing participants for peripheral versus perifoveal visual processing in extrastriate visual cortex including primary auditory cortex, MT+/V5, superior-temporal auditory and multisensory and/or supramodal regions, such as posterior parietal cortex, frontal eye fields, anterior cingulate, and supplementary eye fields. Overall, these data demonstrate the contribution of neuroplasticity in multiple systems including primary auditory cortex, supramodal and multisensory regions, to altered visual processing in

  14. Peripheral visual feedback: a powerful means of supporting effective attention allocation in event-driven, data-rich environments.

    Science.gov (United States)

    Nikolic, M I; Sarter, N B

    2001-01-01

    Breakdowns in human-automation coordination in data-rich, event-driven domains such as aviation can be explained in part by a mismatch between the high degree of autonomy yet low observability of modern technology. To some extent, the latter is the result of an increasing reliance in feedback design on foveal vision--an approach that fails to support pilots in tracking system-induced changes and events in parallel with performing concurrent flight-related tasks. One possible solution to the problem is the distribution of tasks and information across sensory modalities and processing channels. A simulator study is presented that compared the effectiveness of current foveal feedback and two implementations of peripheral visual feedback for keeping pilots informed about uncommanded changes in the status of an automated cockpit system. Both peripheral visual displays resulted in higher detection rates and faster response times, without interfering with the performance of concurrent visual tasks any more than does currently available automation feedback. Potential applications include improved display designs that support effective attention allocation in a variety of complex dynamic environments, such as aviation, process control, and medicine.

  15. The risk of pedestrian collisions with peripheral visual field loss

    OpenAIRE

    Peli, Eli; Apfelbaum, Henry; Berson, Eliot L.; Goldstein, Robert B.

    2016-01-01

    Patients with peripheral field loss complain of colliding with other pedestrians in open-space environments such as shopping malls. Field expansion devices (e.g., prisms) can create artificial peripheral islands of vision. We investigated the visual angle at which these islands can be most effective for avoiding pedestrian collisions, by modeling the collision risk density as a function of bearing angle of pedestrians relative to the patient. Pedestrians at all possible locations were assumed...

  16. Raman spectroscopic detection of peripheral nerves towards nerve-sparing surgery

    Science.gov (United States)

    Minamikawa, Takeo; Harada, Yoshinori; Takamatsu, Tetsuro

    2017-02-01

    The peripheral nervous system plays an important role in motility, sensory, and autonomic functions of the human body. Preservation of peripheral nerves in surgery, namely nerve-sparing surgery, is now promising technique to avoid functional deficits of the limbs and organs following surgery as an aspect of the improvement of quality of life of patients. Detection of peripheral nerves including myelinated and unmyelinated nerves is required for the nerve-sparing surgery; however, conventional nerve identification scheme is sometimes difficult to identify peripheral nerves due to similarity of shape and color to non-nerve tissues or its limited application to only motor peripheral nerves. To overcome these issues, we proposed a label-free detection technique of peripheral nerves by means of Raman spectroscopy. We found several fingerprints of peripheral myelinated and unmyelinated nerves by employing a modified principal component analysis of typical spectra including myelinated nerve, unmyelinated nerve, and adjacent tissues. We finally realized the sensitivity of 94.2% and the selectivity of 92.0% for peripheral nerves including myelinated and unmyelinated nerves against adjacent tissues. Although further development of an intraoperative Raman spectroscopy system is required for clinical use, our proposed approach will serve as a unique and powerful tool for peripheral nerve detection for nerve-sparing surgery in the future.

  17. Detecting peripheral-based attacks on the host memory

    CERN Document Server

    Stewin, Patrick

    2015-01-01

    This work addresses stealthy peripheral-based attacks on host computers and presents a new approach to detecting them. Peripherals can be regarded as separate systems that have a dedicated processor and dedicated runtime memory to handle their tasks. The book addresses the problem that peripherals generally communicate with the host via the host’s main memory, storing cryptographic keys, passwords, opened files and other sensitive data in the process – an aspect attackers are quick to exploit.  Here, stealthy malicious software based on isolated micro-controllers is implemented to conduct an attack analysis, the results of which provide the basis for developing a novel runtime detector. The detector reveals stealthy peripheral-based attacks on the host’s main memory by exploiting certain hardware properties, while a permanent and resource-efficient measurement strategy ensures that the detector is also capable of detecting transient attacks, which can otherwise succeed when the applied strategy only me...

  18. Morphological dissociation between visual pathways and cortex: MRI of visually-deprived patients with congenital peripheral blindness

    International Nuclear Information System (INIS)

    Breitenseher, M.; Prayer Wimberger, D.; Trattnig, S.; Kramer, J.; Uhl, F.; Deecke, L.

    1998-01-01

    MRI was used to study possible morphological changes in the visual system in 12 patients suffering from congenital blindness of peripheral (ocular) origin. While their optical pathways showed degeneration, hypoplasia or atrophy in 7 out of 12 cases, the occipital cortex appeared normal in all cases. This dissociation between afferent pathways and the cortex is contrary to the assumption that visually deprived cortex may undergo degeneration. The finding is congruent with evidence that the occipital cortex is used for other, nonvisual functions. (orig.)

  19. Morphological dissociation between visual pathways and cortex: MRI of visually-deprived patients with congenital peripheral blindness

    Energy Technology Data Exchange (ETDEWEB)

    Breitenseher, M.; Prayer Wimberger, D.; Trattnig, S.; Kramer, J. [MR-Institute of the Medical Faculty and Clinic for Diagnostic Radiology, University of Vienna (Austria); Uhl, F.; Deecke, L. [Department of Neurology, University of Vienna (Austria)

    1998-07-01

    MRI was used to study possible morphological changes in the visual system in 12 patients suffering from congenital blindness of peripheral (ocular) origin. While their optical pathways showed degeneration, hypoplasia or atrophy in 7 out of 12 cases, the occipital cortex appeared normal in all cases. This dissociation between afferent pathways and the cortex is contrary to the assumption that visually deprived cortex may undergo degeneration. The finding is congruent with evidence that the occipital cortex is used for other, nonvisual functions. (orig.) With 3 figs., 1 tab., 23 refs.

  20. Mini-review: Far peripheral vision.

    Science.gov (United States)

    Simpson, Michael J

    2017-11-01

    The region of far peripheral vision, beyond 60 degrees of visual angle, is important to the evaluation of peripheral dark shadows (negative dysphotopsia) seen by some intraocular lens (IOL) patients. Theoretical calculations show that the limited diameter of an IOL affects ray paths at large angles, leading to a dimming of the main image for small pupils, and to peripheral illumination by light bypassing the IOL for larger pupils. These effects are rarely bothersome, and cataract surgery is highly successful, but there is a need to improve the characterization of far peripheral vision, for both pseudophakic and phakic eyes. Perimetry is the main quantitative test, but the purpose is to evaluate pathologies rather than characterize vision (and object and image regions are no longer uniquely related in the pseudophakic eye). The maximum visual angle is approximately 105 0 , but there is limited information about variations with age, race, or refractive error (in case there is an unexpected link with the development of myopia), or about how clear cornea, iris location, and the limiting retina are related. Also, the detection of peripheral motion is widely recognized to be important, yet rarely evaluated. Overall, people rarely complain specifically about this visual region, but with "normal" vision including an IOL for >5% of people, and increasing interest in virtual reality and augmented reality, there are new reasons to characterize peripheral vision more completely. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Visual recovery after surgical repair of chronic macular detachment associated with peripheral retinoschisis

    OpenAIRE

    Vaidehi S. Dedania; Devon H. Ghodasra; Mark W. Johnson

    2018-01-01

    Purpose: To report 2 cases of chronic macular detachment associated with peripheral retinoschisis in which surgical repair resulted in significant visual recovery. Observations: A 44-year-old man and 60-year-old woman were evaluated for chronic macular detachment, with a duration of 5 years and 6 months, respectively. In each case, optical coherence tomography was used to establish a diagnosis of full-thickness macular detachment resulting from peripheral retinoschisis and to confirm or ident...

  2. A Pilot Evaluation of On-Road Detection Performance by Drivers with Hemianopia Using Oblique Peripheral Prisms

    Directory of Open Access Journals (Sweden)

    Alex R. Bowers

    2012-01-01

    Full Text Available Aims. Homonymous hemianopia (HH, a severe visual consequence of stroke, causes difficulties in detecting obstacles on the nonseeing (blind side. We conducted a pilot study to evaluate the effects of oblique peripheral prisms, a novel development in optical treatments for HH, on detection of unexpected hazards when driving. Methods. Twelve people with complete HH (median 49 years, range 29–68 completed road tests with sham oblique prism glasses (SP and real oblique prism glasses (RP. A masked evaluator rated driving performance along the 25 km routes on busy streets in Ghent, Belgium. Results. The proportion of satisfactory responses to unexpected hazards on the blind side was higher in the RP than the SP drive (80% versus 30%; P=0.001, but similar for unexpected hazards on the seeing side. Conclusions. These pilot data suggest that oblique peripheral prisms may improve responses of people with HH to blindside hazards when driving and provide the basis for a future, larger-sample clinical trial. Testing responses to unexpected hazards in areas of heavy vehicle and pedestrian traffic appears promising as a real-world outcome measure for future evaluations of HH rehabilitation interventions aimed at improving detection when driving.

  3. Fusion for Audio-Visual Laughter Detection

    NARCIS (Netherlands)

    Reuderink, B.

    2007-01-01

    Laughter is a highly variable signal, and can express a spectrum of emotions. This makes the automatic detection of laughter a challenging but interesting task. We perform automatic laughter detection using audio-visual data from the AMI Meeting Corpus. Audio-visual laughter detection is performed

  4. Which visual sight skill tested and developed the interaction between central and peripheral vision case duels dribbling soccer skills

    Directory of Open Access Journals (Sweden)

    Zerf Mohammed

    2016-09-01

    Full Text Available The present paper analyses the effects of visual keep sight to test and develop the interaction between central and peripheral vision the case of duels dribbling among soccer under 17 years. Where This research aims to propose a method evaluating and coaching this skill in the absence of laboratory tests and virtual visual exercises as a way for Algerian coaches to control the progress of their players. From the principle that the team which wins the most duels has the best chance of winning the game. [1] Our research supports the hypothesis which confirms in one hand that Dynamic visual acuity is the combine between Peripheral and Central vision to have one eye on the ball and the other on the defined [2] . While some authors confirm that the Top-class football players do not watch their steps, but dribble with their heads up [3]. Whereas Previous studies confirm estimate of distance ball foot player is the strategy to master this skill [4] which requires the involvement of the commitment of peripheral vision for information and central vision to master the ball [5]. From the proof and results statistics applied in the current study, we confirm that narrow spaces require the interaction of central vision than peripheral vision. Otherwise, free spaces require peripheral vision than the central vision. Which leaves us to confirm that peripheral vision in the limited space [6] can suffer because the player needs to pay close attention to each contact with the ball [7].

  5. Detection of free gastric cancer cell in peripheral and portal blood

    Energy Technology Data Exchange (ETDEWEB)

    Bang, Ho Yoon; Lee, Jong Inn [Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    1998-01-01

    In fact, there is no definite treatment modality after liver or hematogenous metastasis in the gastric cancer. So it is important to develop a new method to predict the high risk patients for systemic recurrence. If we can detect metastatic cell in circulation, it may be beneficial in assessing tumor progression, metastatic potential and prognosis. To establish the RT-PCR methodology for detection of CEA expressing cancer cells in peripheral and portal blood and to define the relationship between peripheral and portal blood detection rate of gastric cancer patients, we performed RT-PCR analysis with peripheral and portal blood samples from 24 patients with gastric cancer (stage Ia,b, n=3; stage II, n=2; stage IIIa, n=9; stage IIIb, n=7; stage IV, n=3) and checked serum CEA level preoperatively. Mean age was 49.2 years old and male : female was 1.2 : 2 (13:11 patients). The mean serum CEA level was 10.4 ng/ml and that was higher than normal in only 2 cases. There was no positive case of tumor cell in portal and peripheral blood using RT-PCR and CEA gene specific primer. Our results indicate that the incidence of circulating cancer cells is unexpectedly very low even in advanced gastric cancer patients. (author). 20 refs.

  6. Detection of free gastric cancer cell in peripheral and portal blood

    International Nuclear Information System (INIS)

    Bang, Ho Yoon; Lee, Jong Inn

    1998-01-01

    In fact, there is no definite treatment modality after liver or hematogenous metastasis in the gastric cancer. So it is important to develop a new method to predict the high risk patients for systemic recurrence. If we can detect metastatic cell in circulation, it may be beneficial in assessing tumor progression, metastatic potential and prognosis. To establish the RT-PCR methodology for detection of CEA expressing cancer cells in peripheral and portal blood and to define the relationship between peripheral and portal blood detection rate of gastric cancer patients, we performed RT-PCR analysis with peripheral and portal blood samples from 24 patients with gastric cancer (stage Ia,b, n=3; stage II, n=2; stage IIIa, n=9; stage IIIb, n=7; stage IV, n=3) and checked serum CEA level preoperatively. Mean age was 49.2 years old and male : female was 1.2 : 2 (13:11 patients). The mean serum CEA level was 10.4 ng/ml and that was higher than normal in only 2 cases. There was no positive case of tumor cell in portal and peripheral blood using RT-PCR and CEA gene specific primer. Our results indicate that the incidence of circulating cancer cells is unexpectedly very low even in advanced gastric cancer patients. (author). 20 refs

  7. Towards an assistive peripheral visual prosthesis for long-term treatment of retinitis pigmentosa: evaluating mobility performance in immersive simulations

    Science.gov (United States)

    Zapf, Marc Patrick H.; Boon, Mei-Ying; Matteucci, Paul B.; Lovell, Nigel H.; Suaning, Gregg J.

    2015-06-01

    Objective. The prospective efficacy of a future peripheral retinal prosthesis complementing residual vision to raise mobility performance in non-end stage retinitis pigmentosa (RP) was evaluated using simulated prosthetic vision (SPV). Approach. Normally sighted volunteers were fitted with a wide-angle head-mounted display and carried out mobility tasks in photorealistic virtual pedestrian scenarios. Circumvention of low-lying obstacles, path following, and navigating around static and moving pedestrians were performed either with central simulated residual vision of 10° alone or enhanced by assistive SPV in the lower and lateral peripheral visual field (VF). Three layouts of assistive vision corresponding to hypothetical electrode array layouts were compared, emphasizing higher visual acuity, a wider visual angle, or eccentricity-dependent acuity across an intermediate angle. Movement speed, task time, distance walked and collisions with the environment were analysed as performance measures. Main results. Circumvention of low-lying obstacles was improved with all tested configurations of assistive SPV. Higher-acuity assistive vision allowed for greatest improvement in walking speeds—14% above that of plain residual vision, while only wide-angle and eccentricity-dependent vision significantly reduced the number of collisions—both by 21%. Navigating around pedestrians, there were significant reductions in collisions with static pedestrians by 33% and task time by 7.7% with the higher-acuity layout. Following a path, higher-acuity assistive vision increased walking speed by 9%, and decreased collisions with stationary cars by 18%. Significance. The ability of assistive peripheral prosthetic vision to improve mobility performance in persons with constricted VFs has been demonstrated. In a prospective peripheral visual prosthesis, electrode array designs need to be carefully tailored to the scope of tasks in which a device aims to assist. We posit that maximum

  8. Enhanced peripheral visual processing in congenitally deaf humans is supported by multiple brain regions, including primary auditory cortex

    OpenAIRE

    Scott, Gregory D.; Karns, Christina M.; Dow, Mark W.; Stevens, Courtney; Neville, Helen J.

    2014-01-01

    Brain reorganization associated with altered sensory experience clarifies the critical role of neuroplasticity in development. An example is enhanced peripheral visual processing associated with congenital deafness, but the neural systems supporting this have not been fully characterized. A gap in our understanding of deafness-enhanced peripheral vision is the contribution of primary auditory cortex. Previous studies of auditory cortex that use anatomical normalization across participants wer...

  9. Detection of Toxoplasma gondii DNA in peripheral blood and aqueous humor of patients with Toxoplasmic active focal necrotizing retinochoroiditis using real-time PCR

    Directory of Open Access Journals (Sweden)

    Fabio Felipe dos Santos

    2015-12-01

    Full Text Available ABSTRACT Purpose: To evaluate the ability of real-time quantitative PCR (qPCR for detectingToxoplasma gondii DNA in the peripheral blood and aqueous humor of patients with toxoplasmic active focal necrotizing retinochoroiditis. Methods: Fifty-five patients with infectious uveitis seen from 2009 to 2013 at the Department of Ophthalmology and Visual Sciences of the Federal University of São Paulo were enrolled in this study. Forty-three patients had toxoplasmic active focal necrotizing retinochoroiditis, and the remaining 12 had non-toxoplasmic infectious uveitis and served as controls. qPCR analysis forT. gondii DNA was performed on the patients' peripheral blood and aqueous humor samples. Results: The qPCR was positive for T. gondii DNA in 37.21% (16/43 of the aqueous humor samples and 2.33% (1/43 of the peripheral blood samples; further, 16.27% (7/43 of the patients had positive results in both their blood and aqueous humor samples. Conclusion: qPCR was able to detect T. gondii DNA in patients with toxoplasmic active focal necrotizing retinochoroiditis in the blood as well as the aqueous humor and can help with the diagnosis of the disease.

  10. Are Visual Peripheries Forever Young?

    Directory of Open Access Journals (Sweden)

    Kalina Burnat

    2015-01-01

    Full Text Available The paper presents a concept of lifelong plasticity of peripheral vision. Central vision processing is accepted as critical and irreplaceable for normal perception in humans. While peripheral processing chiefly carries information about motion stimuli features and redirects foveal attention to new objects, it can also take over functions typical for central vision. Here I review the data showing the plasticity of peripheral vision found in functional, developmental, and comparative studies. Even though it is well established that afferent projections from central and peripheral retinal regions are not established simultaneously during early postnatal life, central vision is commonly used as a general model of development of the visual system. Based on clinical studies and visually deprived animal models, I describe how central and peripheral visual field representations separately rely on early visual experience. Peripheral visual processing (motion is more affected by binocular visual deprivation than central visual processing (spatial resolution. In addition, our own experimental findings show the possible recruitment of coarse peripheral vision for fine spatial analysis. Accordingly, I hypothesize that the balance between central and peripheral visual processing, established in the course of development, is susceptible to plastic adaptations during the entire life span, with peripheral vision capable of taking over central processing.

  11. Are visual peripheries forever young?

    Science.gov (United States)

    Burnat, Kalina

    2015-01-01

    The paper presents a concept of lifelong plasticity of peripheral vision. Central vision processing is accepted as critical and irreplaceable for normal perception in humans. While peripheral processing chiefly carries information about motion stimuli features and redirects foveal attention to new objects, it can also take over functions typical for central vision. Here I review the data showing the plasticity of peripheral vision found in functional, developmental, and comparative studies. Even though it is well established that afferent projections from central and peripheral retinal regions are not established simultaneously during early postnatal life, central vision is commonly used as a general model of development of the visual system. Based on clinical studies and visually deprived animal models, I describe how central and peripheral visual field representations separately rely on early visual experience. Peripheral visual processing (motion) is more affected by binocular visual deprivation than central visual processing (spatial resolution). In addition, our own experimental findings show the possible recruitment of coarse peripheral vision for fine spatial analysis. Accordingly, I hypothesize that the balance between central and peripheral visual processing, established in the course of development, is susceptible to plastic adaptations during the entire life span, with peripheral vision capable of taking over central processing.

  12. Visual Inspection for Caries Detection

    DEFF Research Database (Denmark)

    Gimenez, T; Piovesan, C; Braga, M M

    2015-01-01

    July 2014 to identify published and nonpublished studies in English. Studies of visual inspection were included that 1) assessed accuracy of the method in detecting caries lesions; 2) were performed on occlusal, proximal, or free smooth surfaces in primary or permanent teeth; 3) had a reference...... (from 5,808 articles initially identified) and 1 abstract (from 168) met the inclusion criteria. In general, the analysis demonstrated that the visual method had good accuracy for detecting caries lesions. Although laboratory and clinical studies have presented similar accuracy, clinically obtained...... caries detection method has good overall performance. Furthermore, although the identified studies had high heterogeneity and risk of bias, the use of detailed and validated indices seems to improve the accuracy of the method....

  13. Decision-level fusion for audio-visual laughter detection

    NARCIS (Netherlands)

    Reuderink, B.; Poel, M.; Truong, K.; Poppe, R.; Pantic, M.

    2008-01-01

    Laughter is a highly variable signal, which can be caused by a spectrum of emotions. This makes the automatic detection of laughter a challenging, but interesting task. We perform automatic laughter detection using audio-visual data from the AMI Meeting Corpus. Audio-visual laughter detection is

  14. Decision-Level Fusion for Audio-Visual Laughter Detection

    NARCIS (Netherlands)

    Reuderink, B.; Poel, Mannes; Truong, Khiet Phuong; Poppe, Ronald Walter; Pantic, Maja; Popescu-Belis, Andrei; Stiefelhagen, Rainer

    Laughter is a highly variable signal, which can be caused by a spectrum of emotions. This makes the automatic detection of laugh- ter a challenging, but interesting task. We perform automatic laughter detection using audio-visual data from the AMI Meeting Corpus. Audio- visual laughter detection is

  15. Action video game players and deaf observers have larger Goldmann visual fields.

    Science.gov (United States)

    Buckley, David; Codina, Charlotte; Bhardwaj, Palvi; Pascalis, Olivier

    2010-03-05

    We used Goldmann kinetic perimetry to compare how training and congenital auditory deprivation may affect the size of the visual field. We measured the ability of action video game players and deaf observers to detect small moving lights at various locations in the central (around 30 degrees from fixation) and peripheral (around 60 degrees ) visual fields. Experiment 1 found that 10 habitual video game players showed significantly larger central and peripheral field areas than 10 controls. In Experiment 2 we found that 13 congenitally deaf observers had significantly larger visual fields than 13 hearing controls for both the peripheral and central fields. Here the greatest differences were found in the lower parts of the fields. Comparison of the two groups showed that whereas VGP players have a more uniform increase in field size in both central and peripheral fields deaf observers show non-uniform increases with greatest increases in lower parts of the visual field.

  16. Visual motion detection and habitat preference in Anolis lizards.

    Science.gov (United States)

    Steinberg, David S; Leal, Manuel

    2016-11-01

    The perception of visual stimuli has been a major area of inquiry in sensory ecology, and much of this work has focused on coloration. However, for visually oriented organisms, the process of visual motion detection is often equally crucial to survival and reproduction. Despite the importance of motion detection to many organisms' daily activities, the degree of interspecific variation in the perception of visual motion remains largely unexplored. Furthermore, the factors driving this potential variation (e.g., ecology or evolutionary history) along with the effects of such variation on behavior are unknown. We used a behavioral assay under laboratory conditions to quantify the visual motion detection systems of three species of Puerto Rican Anolis lizard that prefer distinct structural habitat types. We then compared our results to data previously collected for anoles from Cuba, Puerto Rico, and Central America. Our findings indicate that general visual motion detection parameters are similar across species, regardless of habitat preference or evolutionary history. We argue that these conserved sensory properties may drive the evolution of visual communication behavior in this clade.

  17. Making the invisible visible: verbal but not visual cues enhance visual detection.

    Science.gov (United States)

    Lupyan, Gary; Spivey, Michael J

    2010-07-07

    Can hearing a word change what one sees? Although visual sensitivity is known to be enhanced by attending to the location of the target, perceptual enhancements of following cues to the identity of an object have been difficult to find. Here, we show that perceptual sensitivity is enhanced by verbal, but not visual cues. Participants completed an object detection task in which they made an object-presence or -absence decision to briefly-presented letters. Hearing the letter name prior to the detection task increased perceptual sensitivity (d'). A visual cue in the form of a preview of the to-be-detected letter did not. Follow-up experiments found that the auditory cuing effect was specific to validly cued stimuli. The magnitude of the cuing effect positively correlated with an individual measure of vividness of mental imagery; introducing uncertainty into the position of the stimulus did not reduce the magnitude of the cuing effect, but eliminated the correlation with mental imagery. Hearing a word made otherwise invisible objects visible. Interestingly, seeing a preview of the target stimulus did not similarly enhance detection of the target. These results are compatible with an account in which auditory verbal labels modulate lower-level visual processing. The findings show that a verbal cue in the form of hearing a word can influence even the most elementary visual processing and inform our understanding of how language affects perception.

  18. Making the invisible visible: verbal but not visual cues enhance visual detection.

    Directory of Open Access Journals (Sweden)

    Gary Lupyan

    Full Text Available BACKGROUND: Can hearing a word change what one sees? Although visual sensitivity is known to be enhanced by attending to the location of the target, perceptual enhancements of following cues to the identity of an object have been difficult to find. Here, we show that perceptual sensitivity is enhanced by verbal, but not visual cues. METHODOLOGY/PRINCIPAL FINDINGS: Participants completed an object detection task in which they made an object-presence or -absence decision to briefly-presented letters. Hearing the letter name prior to the detection task increased perceptual sensitivity (d'. A visual cue in the form of a preview of the to-be-detected letter did not. Follow-up experiments found that the auditory cuing effect was specific to validly cued stimuli. The magnitude of the cuing effect positively correlated with an individual measure of vividness of mental imagery; introducing uncertainty into the position of the stimulus did not reduce the magnitude of the cuing effect, but eliminated the correlation with mental imagery. CONCLUSIONS/SIGNIFICANCE: Hearing a word made otherwise invisible objects visible. Interestingly, seeing a preview of the target stimulus did not similarly enhance detection of the target. These results are compatible with an account in which auditory verbal labels modulate lower-level visual processing. The findings show that a verbal cue in the form of hearing a word can influence even the most elementary visual processing and inform our understanding of how language affects perception.

  19. Detection of silver-stained nucleolar organizer regions in the peripheral blood T lymphocytes in nasopharyngeal carcinoma patients

    International Nuclear Information System (INIS)

    Li Xianming; Wu Dong; Chen Shanyi; Ren Zheping; Chen Yixin; Wang Xiuqing

    2002-01-01

    Objective: To evaluate the clinical significance of detecting silver-stained nucleolar organizer regions (Ag-NOR) in the peripheral blood T lymphocytes in nasopharyngeal carcinoma (NPC) patients. Methods: Ag-NOR in the peripheral blood T lymphocytes detected in 36 healthy subjects served as control. Those in 73 newly diagnosed but untreated, 11 recurrent (and/or metastatic) and 32 treated NPC patients in follow-up were monitored. The dynamic variations in the level of Ag-NORs in the peripheral blood T lymphocytes in the pre-radiotherapy (pre-RT), during RT and post-RT were evaluated in part of the newly diagnosed patients. Results: The level of Ag-NORs in the peripheral blood T lymphocytes in all groups of NPC patients were significantly lower as compared to the health controls (P 0.05). The level of Ag-NORs during RT significantly decreased as compared to that of pre-RT (P 0.05). Conclusions: Detection of Ag-NORs in the peripheral blood T lymphocytes is of significance in evaluating the outcome, predicting prognosis and even in making the diagnosis and staging for NPC patients

  20. Single Sensor Gait Analysis to Detect Diabetic Peripheral Neuropathy: A Proof of Principle Study

    Directory of Open Access Journals (Sweden)

    Patrick Esser

    2018-01-01

    Full Text Available This study explored the potential utility of gait analysis using a single sensor unit (inertial measurement unit [IMU] as a simple tool to detect peripheral neuropathy in people with diabetes. Seventeen people (14 men aged 63±9 years (mean±SD with diabetic peripheral neuropathy performed a 10-m walk test instrumented with an IMU on the lower back. Compared to a reference healthy control data set (matched by gender, age, and body mass index both spatiotemporal and gait control variables were different between groups, with walking speed, step time, and SDa (gait control parameter demonstrating good discriminatory power (receiver operating characteristic area under the curve >0.8. These results provide a proof of principle of this relatively simple approach which, when applied in clinical practice, can detect a signal from those with known diabetes peripheral neuropathy. The technology has the potential to be used both routinely in the clinic and for tele-health applications. Further research should focus on investigating its efficacy as an early indicator of or effectiveness of the management of peripheral neuropathy. This could support the development of interventions to prevent complications such as foot ulceration or Charcot's foot.

  1. Detection of Sirtuin-1 protein expression in peripheral blood leukocytes in dogs.

    Science.gov (United States)

    Yoshimura, Kuniko; Matsuu, Aya; Sasaki, Kai; Momoi, Yasuyuki

    2018-05-11

    Sirtuin-1 (SIRT1) is a nicotinamide adenine dinucleotide (NAD + )-dependent histone deacetylase with a large number of protein substrates. It has attracted a lot of attention in association with extending lifespan. The objective of this study was to enable the evaluation of SIRT1 expression in peripheral blood mononuclear cells (PBMCs) from dogs by flow cytometry. Three transcript variants were amplified from PBMCs by reverse transcription PCR and the nucleotide sequences were analyzed. On the basis deduced amino acid sequence, a monoclonal antibody against human SIRT1, 1F3, was selected to detect canine SIRT1. Canine SIRT1 in peripheral blood mononuclear cells was successfully detected by western blotting using this antibody. Intracellular canine SIRT1 was also detected in permeabilized 293T cells transfected with a canine SIRT1 expression plasmid by flow cytometry using this antibody. SIRT1 was detected in all leukocyte subsets including lymphocytes, granulocytes and monocytes. The expression level was markedly different among individual dogs. These results indicated that the method applied in this study is useful for evaluating canine SIRT1 levels in PBMCs from dogs.

  2. Immune mapping of the peripheral part of the visual analyzer and optic nerve

    Directory of Open Access Journals (Sweden)

    V. G. Likhvantseva

    2014-10-01

    Full Text Available Aim. To perform immune mapping of the peripheral part of visual analyzer and optic nerve in order to identify potential antigenic targets of autoimmune attack. Methods. Eyes enucleated for terminal painful glaucoma (n = 30 were studied. Immunohistochemistry (IHC was performed on paraffin-embedded sections of isolated retina and optic nerve using a broad panel of antibodies, i.e., monoclonal murine anti-MBP (myelin basic protein antibodies, polyclonal rabbit anti-alpha fodrin antibodies, monoclonal murine anti-NSE2 (neuron-specific enolase antibodies, monoclonal murine anti-GFAP (glial fibrillary acidic protein, and polyclonal rabbit anti-S100 antibodies. IHC reaction was visualized using Mouse and Rabbit Specific HRP / AEC Detection IHC Kit. IHC reaction without primary antibodies included was a negative control. IHC reaction was considered as follows: negative — no specific cellular staining or less than 10 % of cells are stained; mild — 10‑30 % of cells are stained (+; moderate — 30‑75 % of cells are stained (++; marked — more than 75 % of cells are stained (+++; overexpression — 100 % of cells intensively express markers. Additionally, staining intensity was considered as mild (+1, moderate (+2, strong (+3 and intense (+4.Results. Immune mapping with a broad panel of monoclonal antibodies identified ocular structures which were stained with IHC markers. Retina was stained with almost all markers of neural differentiation (i.e., antibodies against NSE, GFAP, S100, and α-fodrin excepting anti-MBP autoantibodies. IHC reaction intensity in retinal layers and structures varied and depended on markers. Moderate (2+ staining with antibodies against MBP, NSE, GFAP, and S100 and marked (3+ staining with antibodies against alpha-fodrin was detected in the cytoplasm of optic nerve glia.Conclusion. Complete labelling of retina structures was performed. As a result, IHC profiles of retinal neurons, optic nerve axons

  3. Immune mapping of the peripheral part of the visual analyzer and optic nerve

    Directory of Open Access Journals (Sweden)

    V. G. Likhvantseva

    2014-01-01

    Full Text Available Aim. To perform immune mapping of the peripheral part of visual analyzer and optic nerve in order to identify potential antigenic targets of autoimmune attack. Methods. Eyes enucleated for terminal painful glaucoma (n = 30 were studied. Immunohistochemistry (IHC was performed on paraffin-embedded sections of isolated retina and optic nerve using a broad panel of antibodies, i.e., monoclonal murine anti-MBP (myelin basic protein antibodies, polyclonal rabbit anti-alpha fodrin antibodies, monoclonal murine anti-NSE2 (neuron-specific enolase antibodies, monoclonal murine anti-GFAP (glial fibrillary acidic protein, and polyclonal rabbit anti-S100 antibodies. IHC reaction was visualized using Mouse and Rabbit Specific HRP / AEC Detection IHC Kit. IHC reaction without primary antibodies included was a negative control. IHC reaction was considered as follows: negative — no specific cellular staining or less than 10 % of cells are stained; mild — 10‑30 % of cells are stained (+; moderate — 30‑75 % of cells are stained (++; marked — more than 75 % of cells are stained (+++; overexpression — 100 % of cells intensively express markers. Additionally, staining intensity was considered as mild (+1, moderate (+2, strong (+3 and intense (+4.Results. Immune mapping with a broad panel of monoclonal antibodies identified ocular structures which were stained with IHC markers. Retina was stained with almost all markers of neural differentiation (i.e., antibodies against NSE, GFAP, S100, and α-fodrin excepting anti-MBP autoantibodies. IHC reaction intensity in retinal layers and structures varied and depended on markers. Moderate (2+ staining with antibodies against MBP, NSE, GFAP, and S100 and marked (3+ staining with antibodies against alpha-fodrin was detected in the cytoplasm of optic nerve glia.Conclusion. Complete labelling of retina structures was performed. As a result, IHC profiles of retinal neurons, optic nerve axons

  4. Neurophysiological assessment of auditory, peripheral nerve, somatosensory, and visual system function after developmental exposure to gasoline, E15, and E85 vapors.

    Data.gov (United States)

    U.S. Environmental Protection Agency — Visual, auditory, somatosensory, and peripheral nerve evoked responses. This dataset is associated with the following publication: Herr , D., D. Freeborn , L. Degn ,...

  5. Visual attention measures predict pedestrian detection in central field loss: a pilot study.

    Science.gov (United States)

    Alberti, Concetta F; Horowitz, Todd; Bronstad, P Matthew; Bowers, Alex R

    2014-01-01

    The ability of visually impaired people to deploy attention effectively to maximize use of their residual vision in dynamic situations is fundamental to safe mobility. We conducted a pilot study to evaluate whether tests of dynamic attention (multiple object tracking; MOT) and static attention (Useful Field of View; UFOV) were predictive of the ability of people with central field loss (CFL) to detect pedestrian hazards in simulated driving. 11 people with bilateral CFL (visual acuity 20/30-20/200) and 11 age-similar normally-sighted drivers participated. Dynamic and static attention were evaluated with brief, computer-based MOT and UFOV tasks, respectively. Dependent variables were the log speed threshold for 60% correct identification of targets (MOT) and the increase in the presentation duration for 75% correct identification of a central target when a concurrent peripheral task was added (UFOV divided and selective attention subtests). Participants drove in a simulator and pressed the horn whenever they detected pedestrians that walked or ran toward the road. The dependent variable was the proportion of timely reactions (could have stopped in time to avoid a collision). UFOV and MOT performance of CFL participants was poorer than that of controls, and the proportion of timely reactions was also lower (worse) (84% and 97%, respectively; p = 0.001). For CFL participants, higher proportions of timely reactions correlated significantly with higher (better) MOT speed thresholds (r = 0.73, p = 0.01), with better performance on the UFOV divided and selective attention subtests (r = -0.66 and -0.62, respectively, pattention may provide useful measures of functional visual ability of individuals with CFL relevant to more complex mobility tasks.

  6. Phishing Detection: Analysis of Visual Similarity Based Approaches

    Directory of Open Access Journals (Sweden)

    Ankit Kumar Jain

    2017-01-01

    Full Text Available Phishing is one of the major problems faced by cyber-world and leads to financial losses for both industries and individuals. Detection of phishing attack with high accuracy has always been a challenging issue. At present, visual similarities based techniques are very useful for detecting phishing websites efficiently. Phishing website looks very similar in appearance to its corresponding legitimate website to deceive users into believing that they are browsing the correct website. Visual similarity based phishing detection techniques utilise the feature set like text content, text format, HTML tags, Cascading Style Sheet (CSS, image, and so forth, to make the decision. These approaches compare the suspicious website with the corresponding legitimate website by using various features and if the similarity is greater than the predefined threshold value then it is declared phishing. This paper presents a comprehensive analysis of phishing attacks, their exploitation, some of the recent visual similarity based approaches for phishing detection, and its comparative study. Our survey provides a better understanding of the problem, current solution space, and scope of future research to deal with phishing attacks efficiently using visual similarity based approaches.

  7. Large-scale network analysis of imagination reveals extended but limited top-down components in human visual cognition.

    Directory of Open Access Journals (Sweden)

    Verkhlyutov V.M.

    2014-12-01

    Full Text Available We investigated whole-brain functional magnetic resonance imaging (fMRI activation in a group of 21 healthy adult subjects during perception, imagination and remembering of two dynamic visual scenarios. Activation of the posterior parts of the cortex prevailed when watching videos. The cognitive tasks of imagination and remembering were accompanied by a predominant activity in the anterior parts of the cortex. An independent component analysis identified seven large-scale cortical networks with relatively invariant spatial distributions across all experimental conditions. The time course of their activation over experimental sessions was task-dependent. These detected networks can be interpreted as a recombination of resting state networks. Both central and peripheral networks were identified within the primary visual cortex. The central network around the caudal pole of BA17 and centers of other visual areas was activated only by direct visual stimulation, while the peripheral network responded to the presentation of visual information as well as to the cognitive tasks of imagination and remembering. The latter result explains the particular susceptibility of peripheral and twilight vision to cognitive top-down influences that often result in false-alarm detections.

  8. Brain correlates of automatic visual change detection.

    Science.gov (United States)

    Cléry, H; Andersson, F; Fonlupt, P; Gomot, M

    2013-07-15

    A number of studies support the presence of visual automatic detection of change, but little is known about the brain generators involved in such processing and about the modulation of brain activity according to the salience of the stimulus. The study presented here was designed to locate the brain activity elicited by unattended visual deviant and novel stimuli using fMRI. Seventeen adult participants were presented with a passive visual oddball sequence while performing a concurrent visual task. Variations in BOLD signal were observed in the modality-specific sensory cortex, but also in non-specific areas involved in preattentional processing of changing events. A degree-of-deviance effect was observed, since novel stimuli elicited more activity in the sensory occipital regions and at the medial frontal site than small changes. These findings could be compared to those obtained in the auditory modality and might suggest a "general" change detection process operating in several sensory modalities. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. Visual detection of defects in solder joints

    Science.gov (United States)

    Blaignan, V. B.; Bourbakis, Nikolaos G.; Moghaddamzadeh, Ali; Yfantis, Evangelos A.

    1995-03-01

    The automatic, real-time visual acquisition and inspection of VLSI boards requires the use of machine vision and artificial intelligence methodologies in a new `frame' for the achievement of better results regarding efficiency, products quality and automated service. In this paper the visual detection and classification of different types of defects on solder joints in PC boards is presented by combining several image processing methods, such as smoothing, segmentation, edge detection, contour extraction and shape analysis. The results of this paper are based on simulated solder defects and a real one.

  10. A deafening flash! Visual interference of auditory signal detection.

    Science.gov (United States)

    Fassnidge, Christopher; Cecconi Marcotti, Claudia; Freeman, Elliot

    2017-03-01

    In some people, visual stimulation evokes auditory sensations. How prevalent and how perceptually real is this? 22% of our neurotypical adult participants responded 'Yes' when asked whether they heard faint sounds accompanying flash stimuli, and showed significantly better ability to discriminate visual 'Morse-code' sequences. This benefit might arise from an ability to recode visual signals as sounds, thus taking advantage of superior temporal acuity of audition. In support of this, those who showed better visual relative to auditory sequence discrimination also had poorer auditory detection in the presence of uninformative visual flashes, though this was independent of awareness of visually-evoked sounds. Thus a visually-evoked auditory representation may occur subliminally and disrupt detection of real auditory signals. The frequent natural correlation between visual and auditory stimuli might explain the surprising prevalence of this phenomenon. Overall, our results suggest that learned correspondences between strongly correlated modalities may provide a precursor for some synaesthetic abilities. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Single Sensor Gait Analysis to Detect Diabetic Peripheral Neuropathy: A Proof of Principle Study.

    Science.gov (United States)

    Esser, Patrick; Collett, Johnny; Maynard, Kevin; Steins, Dax; Hillier, Angela; Buckingham, Jodie; Tan, Garry D; King, Laurie; Dawes, Helen

    2018-02-01

    This study explored the potential utility of gait analysis using a single sensor unit (inertial measurement unit [IMU]) as a simple tool to detect peripheral neuropathy in people with diabetes. Seventeen people (14 men) aged 63±9 years (mean±SD) with diabetic peripheral neuropathy performed a 10-m walk test instrumented with an IMU on the lower back. Compared to a reference healthy control data set (matched by gender, age, and body mass index) both spatiotemporal and gait control variables were different between groups, with walking speed, step time, and SDa (gait control parameter) demonstrating good discriminatory power (receiver operating characteristic area under the curve >0.8). These results provide a proof of principle of this relatively simple approach which, when applied in clinical practice, can detect a signal from those with known diabetes peripheral neuropathy. The technology has the potential to be used both routinely in the clinic and for tele-health applications. Further research should focus on investigating its efficacy as an early indicator of or effectiveness of the management of peripheral neuropathy. This could support the development of interventions to prevent complications such as foot ulceration or Charcot's foot. Copyright © 2018 Korean Diabetes Association.

  12. Facilitation of contrast detection in near-peripheral vision.

    Science.gov (United States)

    Giorgi, Robert G; Soong, Grace P; Woods, Russell L; Peli, Eli

    2004-12-01

    Foveal detection of a Gabor patch (target) is facilitated by collinear, displaced high-contrast flankers. Polat and Sagi reported that the same phenomenon occurred in the periphery, but no data were presented [Proc. Natl. Acad. Sci. 91 (1994) 1206]. Others have found no facilitation in a limited number of conditions tested. To resolve this apparent conflict, we measured lateral facilitation in the near-periphery using a range of stimulus parameters. We found facilitation for a range of target-flanker distances for peripheral eccentricities up to 6 degrees , but the magnitude of the effect was less than found in central vision. Facilitation varied across subjects and with spatial frequency. Flanker contrast had no effect over the range evaluated (10-80%). Equal facilitation was found for two global arrangements of the stimulus pattern. Facilitation was found using a temporal, but not a spatial two-alternative forced-choice paradigm, accounting for the different results among previous studies. This finding supports previous indications of the role of attention in altering such facilitation. The value of facilitation from lateral interactions for persons with central vision impairment, who have to shift their attention to a peripheral locus constantly, needs to be examined.

  13. Visual attention measures predict pedestrian detection in central field loss: a pilot study.

    Directory of Open Access Journals (Sweden)

    Concetta F Alberti

    Full Text Available The ability of visually impaired people to deploy attention effectively to maximize use of their residual vision in dynamic situations is fundamental to safe mobility. We conducted a pilot study to evaluate whether tests of dynamic attention (multiple object tracking; MOT and static attention (Useful Field of View; UFOV were predictive of the ability of people with central field loss (CFL to detect pedestrian hazards in simulated driving.11 people with bilateral CFL (visual acuity 20/30-20/200 and 11 age-similar normally-sighted drivers participated. Dynamic and static attention were evaluated with brief, computer-based MOT and UFOV tasks, respectively. Dependent variables were the log speed threshold for 60% correct identification of targets (MOT and the increase in the presentation duration for 75% correct identification of a central target when a concurrent peripheral task was added (UFOV divided and selective attention subtests. Participants drove in a simulator and pressed the horn whenever they detected pedestrians that walked or ran toward the road. The dependent variable was the proportion of timely reactions (could have stopped in time to avoid a collision.UFOV and MOT performance of CFL participants was poorer than that of controls, and the proportion of timely reactions was also lower (worse (84% and 97%, respectively; p = 0.001. For CFL participants, higher proportions of timely reactions correlated significantly with higher (better MOT speed thresholds (r = 0.73, p = 0.01, with better performance on the UFOV divided and selective attention subtests (r = -0.66 and -0.62, respectively, p<0.04, with better contrast sensitivity scores (r = 0.54, p = 0.08 and smaller scotomas (r = -0.60, p = 0.05.Our results suggest that brief laboratory-based tests of visual attention may provide useful measures of functional visual ability of individuals with CFL relevant to more complex mobility tasks.

  14. Deployment of spatial attention to words in central and peripheral vision.

    Science.gov (United States)

    Ducrot, Stéphanie; Grainger, Jonathan

    2007-05-01

    Four perceptual identification experiments examined the influence of spatial cues on the recognition of words presented in central vision (with fixation on either the first or last letter of the target word) and in peripheral vision (displaced left or right of a central fixation point). Stimulus location had a strong effect on word identification accuracy in both central and peripheral vision, showing a strong right visual field superiority that did not depend on eccentricity. Valid spatial cues improved word identification for peripherally presented targets but were largely ineffective for centrally presented targets. Effects of spatial cuing interacted with visual field effects in Experiment 1, with valid cues reducing the right visual field superiority for peripherally located targets, but this interaction was shown to depend on the type of neutral cue. These results provide further support for the role of attentional factors in visual field asymmetries obtained with targets in peripheral vision but not with centrally presented targets.

  15. Oral-Fluid Thiol-Detection Test Identifies Underlying Active Periodontal Disease Not Detected by the Visual Awake Examination.

    Science.gov (United States)

    Queck, Katherine E; Chapman, Angela; Herzog, Leslie J; Shell-Martin, Tamara; Burgess-Cassler, Anthony; McClure, George David

    Periodontal disease in dogs is highly prevalent but can only be accurately diagnosed by performing an anesthetized oral examination with periodontal probing and dental radiography. In this study, 114 dogs had a visual awake examination of the oral cavity and were administered an oral-fluid thiol-detection test prior to undergoing a a full-mouth anesthetized oral examination and digital dental radiographs. The results show the visual awake examination underestimated the presence and severity of active periodontal disease. The thiol-detection test was superior to the visual awake examination at detecting the presence and severity of active periodontal disease and was an indicator of progression toward alveolar bone loss. The thiol-detection test detected active periodontal disease at early stages of development, before any visual cues were present, indicating the need for intervention to prevent periodontal bone loss. Early detection is important because without intervention, dogs with gingivitis (active periodontal disease) progress to irreversible periodontal bone loss (stage 2+). As suggested in the current AAHA guidelines, a thiol-detection test administered in conjunction with the visual awake examination during routine wellness examinations facilitates veterinarian-client communication and mitigates under-diagnosis of periodontal disease and underutilization of dental services. The thiol-detection test can be used to monitor the periodontal health status of the conscious patient during follow-up examinations based on disease severity.

  16. Detection of emotional faces: salient physical features guide effective visual search.

    Science.gov (United States)

    Calvo, Manuel G; Nummenmaa, Lauri

    2008-08-01

    In this study, the authors investigated how salient visual features capture attention and facilitate detection of emotional facial expressions. In a visual search task, a target emotional face (happy, disgusted, fearful, angry, sad, or surprised) was presented in an array of neutral faces. Faster detection of happy and, to a lesser extent, surprised and disgusted faces was found both under upright and inverted display conditions. Inversion slowed down the detection of these faces less than that of others (fearful, angry, and sad). Accordingly, the detection advantage involves processing of featural rather than configural information. The facial features responsible for the detection advantage are located in the mouth rather than the eye region. Computationally modeled visual saliency predicted both attentional orienting and detection. Saliency was greatest for the faces (happy) and regions (mouth) that were fixated earlier and detected faster, and there was close correspondence between the onset of the modeled saliency peak and the time at which observers initially fixated the faces. The authors conclude that visual saliency of specific facial features--especially the smiling mouth--is responsible for facilitated initial orienting, which thus shortens detection. (PsycINFO Database Record (c) 2008 APA, all rights reserved).

  17. Cortical dynamics of visual change detection based on sensory memory.

    Science.gov (United States)

    Urakawa, Tomokazu; Inui, Koji; Yamashiro, Koya; Tanaka, Emi; Kakigi, Ryusuke

    2010-08-01

    Detecting a visual change was suggested to relate closely to the visual sensory memory formed by visual stimuli before the occurrence of the change, because change detection involves identifying a difference between ongoing and preceding sensory conditions. Previous neuroimaging studies showed that an abrupt visual change activates the middle occipital gyrus (MOG). However, it still remains to be elucidated whether the MOG is related to visual change detection based on sensory memory. Here we tried to settle this issue using a new method of stimulation with blue and red LEDs to emphasize a memory-based change detection process. There were two stimuli, a standard trial stimulus and a deviant trial stimulus. The former was a red light lasting 500 ms, and the latter was a red light lasting 250 ms immediately followed by a blue light lasting 250 ms. Effects of the trial-trial interval, 250 approximately 2000 ms, were investigated to know how cortical responses to the abrupt change (from red to blue) were affected by preceding conditions. The brain response to the deviant trial stimulus was recorded by magnetoencephalography. Results of a multi-dipole analysis showed that the activity in the MOG, peaking at around 150 ms after the change onset, decreased in amplitude as the interval increased, but the earlier activity in BA 17/18 was not affected by the interval. These results suggested that the MOG is an important cortical area relating to the sensory memory-based visual change-detecting system. Copyright 2010 Elsevier Inc. All rights reserved.

  18. Peripheral arterial tonometry cannot detect patients at low risk of coronary artery disease

    NARCIS (Netherlands)

    M.M. van den Heuvel (Mieke); O. Sorop (Oana); P. Musters (Paul); R.T. van Domburg (Ron); T.W. Galema (Tjebbe); D.J.G.M. Duncker (Dirk); W.J. van der Giessen (Wim); K. Nieman (Koen)

    2015-01-01

    textabstractBackground Endothelial dysfunction precedes coronary artery disease (CAD) and can be measured by peripheral arterial tonometry (PAT). We examined the applicability of PAT to detect a low risk of CAD in a chest pain clinic. Methods In 93 patients, PAT was performed resulting in reactive

  19. 4D phase contrast flow imaging for in-stent flow visualization and assessment of stent patency in peripheral vascular stents--a phantom study.

    Science.gov (United States)

    Bunck, Alexander C; Jüttner, Alena; Kröger, Jan Robert; Burg, Matthias C; Kugel, Harald; Niederstadt, Thomas; Tiemann, Klaus; Schnackenburg, Bernhard; Crelier, Gerard R; Heindel, Walter; Maintz, David

    2012-09-01

    4D phase contrast flow imaging is increasingly used to study the hemodynamics in various vascular territories and pathologies. The aim of this study was to assess the feasibility and validity of MRI based 4D phase contrast flow imaging for the evaluation of in-stent blood flow in 17 commonly used peripheral stents. 17 different peripheral stents were implanted into a MR compatible flow phantom. In-stent visibility, maximal velocity and flow visualization were assessed and estimates of in-stent patency obtained from 4D phase contrast flow data sets were compared to a conventional 3D contrast-enhanced magnetic resonance angiography (CE-MRA) as well as 2D PC flow measurements. In all but 3 of the tested stents time-resolved 3D particle traces could be visualized inside the stent lumen. Quality of 4D flow visualization and CE-MRA images depended on stent type and stent orientation relative to the magnetic field. Compared to the visible lumen area determined by 3D CE-MRA, estimates of lumen patency derived from 4D flow measurements were significantly higher and less dependent on stent type. A higher number of stents could be assessed for in-stent patency by 4D phase contrast flow imaging (n=14) than by 2D phase contrast flow imaging (n=10). 4D phase contrast flow imaging in peripheral vascular stents is feasible and appears advantageous over conventional 3D contrast-enhanced MR angiography and 2D phase contrast flow imaging. It allows for in-stent flow visualization and flow quantification with varying quality depending on stent type. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  20. Recursive SVM biomarker selection for early detection of breast cancer in peripheral blood.

    Science.gov (United States)

    Zhang, Fan; Kaufman, Howard L; Deng, Youping; Drabier, Renee

    2013-01-01

    Breast cancer is worldwide the second most common type of cancer after lung cancer. Traditional mammography and Tissue Microarray has been studied for early cancer detection and cancer prediction. However, there is a need for more reliable diagnostic tools for early detection of breast cancer. This can be a challenge due to a number of factors and logistics. First, obtaining tissue biopsies can be difficult. Second, mammography may not detect small tumors, and is often unsatisfactory for younger women who typically have dense breast tissue. Lastly, breast cancer is not a single homogeneous disease but consists of multiple disease states, each arising from a distinct molecular mechanism and having a distinct clinical progression path which makes the disease difficult to detect and predict in early stages. In the paper, we present a Support Vector Machine based on Recursive Feature Elimination and Cross Validation (SVM-RFE-CV) algorithm for early detection of breast cancer in peripheral blood and show how to use SVM-RFE-CV to model the classification and prediction problem of early detection of breast cancer in peripheral blood.The training set which consists of 32 health and 33 cancer samples and the testing set consisting of 31 health and 34 cancer samples were randomly separated from a dataset of peripheral blood of breast cancer that is downloaded from Gene Express Omnibus. First, we identified the 42 differentially expressed biomarkers between "normal" and "cancer". Then, with the SVM-RFE-CV we extracted 15 biomarkers that yield zero cross validation score. Lastly, we compared the classification and prediction performance of SVM-RFE-CV with that of SVM and SVM Recursive Feature Elimination (SVM-RFE). We found that 1) the SVM-RFE-CV is suitable for analyzing noisy high-throughput microarray data, 2) it outperforms SVM-RFE in the robustness to noise and in the ability to recover informative features, and 3) it can improve the prediction performance (Area Under

  1. Robotic Detection of Marine Litter Using Deep Visual Detection Models

    OpenAIRE

    Fulton, Michael; Hong, Jungseok; Islam, Md Jahidul; Sattar, Junaed

    2018-01-01

    Trash deposits in aquatic environments have a destructive effect on marine ecosystems and pose a long-term economic and environmental threat. Autonomous underwater vehicles (AUVs) could very well contribute to the solution of this problem by finding and eventually removing trash. A step towards this goal is the successful detection of trash in underwater environments. This paper evaluates a number of deep-learning algorithms to the task of visually detecting trash in realistic underwater envi...

  2. Case of Unilateral Peripheral Cone Dysfunction

    Directory of Open Access Journals (Sweden)

    Yujin Mochizuki

    2012-05-01

    Full Text Available Purpose: Peripheral cone dystrophy is a subgroup of cone dystrophy, and only 4 cases have been reported. We present a patient with unilateral peripheral cone dysfunction and report the functional changes determined by electrophysiological tests and ultrastructural changes determined by spectral domain optical coherence tomography (SD-OCT. Case: A 34-year-old woman complained of blurred vision in both eyes. Our examination showed that her visual acuity was 0.05 OD and 0.2 OS. A relative afferent pupillary defect was present in her right eye. The results of slit-lamp examination, ophthalmoscopy, and fluorescein angiography were normal except for pallor of the right optic disc. SD-OCT showed a diffuse thinning of the retina in the posterior pole of the right eye. A severe constriction of the visual fields was found in both eyes but more in the right eye. The photopic full-field electroretinograms (ERGs were reduced in the right eye but normal in the left eye. The multifocal ERGs were severely reduced throughout the visual field except in the central area of the right eye. The multifocal ERGs from the left eye were normal. The pattern visual evoked responses were within the normal range in both eyes. She had a 5-year history of sniffing paint thinner. Results: Although the visual dysfunction was initially suspected to be due to psychological problems from the results of subjective tests, objective tests indicated a peripheral cone dysfunction in the right eye. The pathophysiological mechanism and the relationship with thinner sniffing were not determined. Conclusions: Our findings indicate that peripheral cone dysfunction can occur unilaterally. Electrophysiology and SD-OCT are valuable tests to perform to determine the pathogenesis of unusual ocular findings objectively.

  3. Beauty and cuteness in peripheral vision

    Science.gov (United States)

    Kuraguchi, Kana; Ashida, Hiroshi

    2015-01-01

    Guo et al. (2011) showed that attractiveness was detectable in peripheral vision. Since there are different types of attractiveness (Rhodes, 2006), we investigated how beauty and cuteness are detected in peripheral vision with a brief presentation. Participants (n = 45) observed two Japanese female faces for 100 ms, then were asked to respond which face was more beautiful (or cuter). The results indicated that both beauty and cuteness were detectable in peripheral vision, but not in the same manner. Discrimination rates for judging beauty were invariant in peripheral and central vision, while discrimination rates for judging cuteness declined in peripheral vision as compared with central vision. This was not explained by lower resolution in peripheral vision. In addition, for male participants, it was more difficult to judge cuteness than beauty in peripheral vision, thus suggesting that gender differences can have a certain effect when judging cuteness. Therefore, central vision might be suitable for judging cuteness while judging beauty might not be affected by either central or peripheral vision. This might be related with the functional difference between beauty and cuteness. PMID:25999883

  4. Foveal Processing Under Concurrent Peripheral Load in Profoundly Deaf Adults

    Science.gov (United States)

    2016-01-01

    Development of the visual system typically proceeds in concert with the development of audition. One result is that the visual system of profoundly deaf individuals differs from that of those with typical auditory systems. While past research has suggested deaf people have enhanced attention in the visual periphery, it is still unclear whether or not this enhancement entails deficits in central vision. Profoundly deaf and typically hearing adults were administered a variant of the useful field of view task that independently assessed performance on concurrent central and peripheral tasks. Identification of a foveated target was impaired by a concurrent selective peripheral attention task, more so in profoundly deaf adults than in the typically hearing. Previous findings of enhanced performance on the peripheral task were not replicated. These data are discussed in terms of flexible allocation of spatial attention targeted towards perceived task demands, and support a modified “division of labor” hypothesis whereby attentional resources co-opted to process peripheral space result in reduced resources in the central visual field. PMID:26657078

  5. Alerts Visualization and Clustering in Network-based Intrusion Detection

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Dr. Li [University of Tennessee; Gasior, Wade C [ORNL; Dasireddy, Swetha [University of Tennessee

    2010-04-01

    Today's Intrusion detection systems when deployed on a busy network overload the network with huge number of alerts. This behavior of producing too much raw information makes it less effective. We propose a system which takes both raw data and Snort alerts to visualize and analyze possible intrusions in a network. Then we present with two models for the visualization of clustered alerts. Our first model gives the network administrator with the logical topology of the network and detailed information of each node that involves its associated alerts and connections. In the second model, flocking model, presents the network administrator with the visual representation of IDS data in which each alert is represented in different color and the alerts with maximum similarity move together. This gives network administrator with the idea of detecting various of intrusions through visualizing the alert patterns.

  6. Evaluation of computer-aided detection and dual energy software in detection of peripheral pulmonary embolism on dual-energy pulmonary CT angiography

    International Nuclear Information System (INIS)

    Lee, Choong Wook; Seo, Joon Beom; Song, Jae-Woo; Kim, Mi-Young; Lee, Ha Young; Park, Yang Shin; Chae, Eun Jin; Jang, Yu Mi; Kim, Namkug; Krauss, Bernard

    2011-01-01

    To evaluate the sensitivity of computer-aided detection(CAD) and dual-energy software('Lung PBV', 'Lung Vessels') for detecting peripheral pulmonary embolism(PE). Between Jan-2007 and Jan-2008, 309 patients underwent dual-energy CT angiography(DECTA) for the evaluation of suspected PE. Among them, 37 patients were retrospectively selected; 21 with PE at segmental-or-below levels and 16 without PE according to clinical reports. A standard computer assisted detection (CAD) package and two new types of software('Lung PBV', 'Lung Vessels') were applied on a dedicated workstation. This resulted in four alternative tests for detecting PE: DECTA alone and DECTA with CAD, 'Lung Vessels' and 'Lung PBV'. Two radiologists independently read all cases at different reading sessions. Two thoracic radiologists set the reference standard by combining all information from DECTA and software. The sensitivity of detection for all, segmental and subsegmental-or-below PE were assessed. The reference standard contained 136 PE(segmental 65, subsegmental-or-below 71). With DECTA alone, the sensitivity of detection for all, segmental and subsegmental-or-below pulmonary arteries was 54.5%/73.7%/34.4%; DECTA with CAD, 57.8%/76.8%/37.9%; DECTA with 'Lung PBV', 61.1%/79.9%/41.4%; DECTA with 'Lung Vessels', 64.0%/78.3%/48.5% respectively. The use of CAD, Lung Vessels and Lung PBV shows improved capability to detect peripheral PE. (orig.)

  7. Genovar: a detection and visualization tool for genomic variants.

    Science.gov (United States)

    Jung, Kwang Su; Moon, Sanghoon; Kim, Young Jin; Kim, Bong-Jo; Park, Kiejung

    2012-05-08

    Along with single nucleotide polymorphisms (SNPs), copy number variation (CNV) is considered an important source of genetic variation associated with disease susceptibility. Despite the importance of CNV, the tools currently available for its analysis often produce false positive results due to limitations such as low resolution of array platforms, platform specificity, and the type of CNV. To resolve this problem, spurious signals must be separated from true signals by visual inspection. None of the previously reported CNV analysis tools support this function and the simultaneous visualization of comparative genomic hybridization arrays (aCGH) and sequence alignment. The purpose of the present study was to develop a useful program for the efficient detection and visualization of CNV regions that enables the manual exclusion of erroneous signals. A JAVA-based stand-alone program called Genovar was developed. To ascertain whether a detected CNV region is a novel variant, Genovar compares the detected CNV regions with previously reported CNV regions using the Database of Genomic Variants (DGV, http://projects.tcag.ca/variation) and the Single Nucleotide Polymorphism Database (dbSNP). The current version of Genovar is capable of visualizing genomic data from sources such as the aCGH data file and sequence alignment format files. Genovar is freely accessible and provides a user-friendly graphic user interface (GUI) to facilitate the detection of CNV regions. The program also provides comprehensive information to help in the elimination of spurious signals by visual inspection, making Genovar a valuable tool for reducing false positive CNV results. http://genovar.sourceforge.net/.

  8. Tumors of peripheral nerves

    International Nuclear Information System (INIS)

    Ho, Michael; Lutz, Amelie M.

    2017-01-01

    Differentiation between malignant and benign tumors of peripheral nerves in the early stages is challenging; however, due to the unfavorable prognosis of malignant tumors early identification is required. To show the possibilities for detection, differential diagnosis and clinical management of peripheral nerve tumors by imaging appearance in magnetic resonance (MR) neurography. Review of current literature available in PubMed and MEDLINE, supplemented by the authors' own observations in clinical practice. Although not pathognomonic, several imaging features have been reported for a differentiation between distinct peripheral nerve tumors. The use of MR neurography enables detection and initial differential diagnosis in tumors of peripheral nerves. Furthermore, it plays an important role in clinical follow-up, targeted biopsy and surgical planning. (orig.) [de

  9. 4D phase contrast flow imaging for in-stent flow visualization and assessment of stent patency in peripheral vascular stents – A phantom study

    International Nuclear Information System (INIS)

    Bunck, Alexander C.; Jüttner, Alena; Kröger, Jan Robert; Burg, Matthias C.; Kugel, Harald; Niederstadt, Thomas; Tiemann, Klaus; Schnackenburg, Bernhard; Crelier, Gerard R.

    2012-01-01

    Purpose: 4D phase contrast flow imaging is increasingly used to study the hemodynamics in various vascular territories and pathologies. The aim of this study was to assess the feasibility and validity of MRI based 4D phase contrast flow imaging for the evaluation of in-stent blood flow in 17 commonly used peripheral stents. Materials and methods: 17 different peripheral stents were implanted into a MR compatible flow phantom. In-stent visibility, maximal velocity and flow visualization were assessed and estimates of in-stent patency obtained from 4D phase contrast flow data sets were compared to a conventional 3D contrast-enhanced magnetic resonance angiography (CE-MRA) as well as 2D PC flow measurements. Results: In all but 3 of the tested stents time-resolved 3D particle traces could be visualized inside the stent lumen. Quality of 4D flow visualization and CE-MRA images depended on stent type and stent orientation relative to the magnetic field. Compared to the visible lumen area determined by 3D CE-MRA, estimates of lumen patency derived from 4D flow measurements were significantly higher and less dependent on stent type. A higher number of stents could be assessed for in-stent patency by 4D phase contrast flow imaging (n = 14) than by 2D phase contrast flow imaging (n = 10). Conclusions: 4D phase contrast flow imaging in peripheral vascular stents is feasible and appears advantageous over conventional 3D contrast-enhanced MR angiography and 2D phase contrast flow imaging. It allows for in-stent flow visualization and flow quantification with varying quality depending on stent type

  10. Peripheral Contour Grouping and Saccade Targeting: The Role of Mirror Symmetry

    Directory of Open Access Journals (Sweden)

    Michaël Sassi

    2014-01-01

    Full Text Available Integrating shape contours in the visual periphery is vital to our ability to locate objects and thus make targeted saccadic eye movements to efficiently explore our surroundings. We tested whether global shape symmetry facilitates peripheral contour integration and saccade targeting in three experiments, in which observers responded to a successful peripheral contour detection by making a saccade towards the target shape. The target contours were horizontally (Experiment 1 or vertically (Experiments 2 and 3 mirror symmetric. Observers responded by making a horizontal (Experiments 1 and 2 or vertical (Experiment 3 eye movement. Based on an analysis of the saccadic latency and accuracy, we conclude that the figure-ground cue of global mirror symmetry in the periphery has little effect on contour integration or on the speed and precision with which saccades are targeted towards objects. The role of mirror symmetry may be more apparent under natural viewing conditions with multiple objects competing for attention, where symmetric regions in the visual field can pre-attentively signal the presence of objects, and thus attract eye movements.

  11. Visualizing the Limits of Low Vision in Detecting Natural Image Features

    NARCIS (Netherlands)

    Hogervorst, M.A.; Damme, W.J.M. van

    2008-01-01

    Purpose. The purpose of our study was to develop a tool to visualize the limitations posed by visual impairments in detecting small and low-contrast elements in natural images. This visualization tool incorporates existing models of several aspects of visual perception, such as the band-limited

  12. Explicit behavioral detection of visual changes develops without their implicit neurophysiological detectability

    Directory of Open Access Journals (Sweden)

    Pessi eLyyra

    2012-03-01

    Full Text Available Change blindness is a failure of explicitly detecting changes between consecutively presented images when separated, e.g., by a brief blank screen. There is a growing body of evidence of implicit detection of even explicitly undetectable changes, pointing to the possibility of the implicit change detection as a prerequisite for its explicit counterpart. We recorded event-related potentials (ERPs of the electroencephalography in adults during an oddball-variant of change blindness flicker paradigm. In this variant, rare pictures with a change were interspersed with frequent pictures with no change. In separate stimulus blocks, the blank screen between the change and no-change picture was either of 100 ms or 500 ms in duration. In both stimulus conditions the participants eventually explicitly detect the changed pictures, the blank screen of the longer duration only requiring in average 10 % longer exposure to the picture series until the ability emerged. However, during the change blindness, ERPs were displaced towards negative polarity at 200–260 ms after the stimulus onset (visual mismatch negativity only with the blank screens of the shorter ISI. Our finding of ‘implicit change blindness’ for pictorial material that, nevertheless, successfully prepares the visual system for explicit change detection suggests that implicit change detection may not be a necessary condition for explicit change detection and that they may recruit at least partially distinct memory mechanisms.

  13. Detection of Emotional Faces: Salient Physical Features Guide Effective Visual Search

    Science.gov (United States)

    Calvo, Manuel G.; Nummenmaa, Lauri

    2008-01-01

    In this study, the authors investigated how salient visual features capture attention and facilitate detection of emotional facial expressions. In a visual search task, a target emotional face (happy, disgusted, fearful, angry, sad, or surprised) was presented in an array of neutral faces. Faster detection of happy and, to a lesser extent,…

  14. Visual Inspection Displays Good Accuracy for Detecting Caries Lesions

    DEFF Research Database (Denmark)

    Twetman, Svante

    2015-01-01

    /QUESTION: To evaluate the overall accuracy of visual methods for detecting caries lesions. SOURCE OF FUNDING: Brazilian government (Process 2012/17888-1). TYPE OF STUDY/DESIGN: Systematic review with meta-analysis of data LEVEL OF EVIDENCE: Level 1: Good-quality, patient-oriented evidence STRENGTH OF RECOMMENDATION......ARTICLE TITLE AND BIBLIOGRAPHIC INFORMATION: Visual inspection for caries detection: a systematic review and meta-analysis. Gimenez T, Piovesan C, Braga MM, Raggio DP, Deery C, Ricketts DN, Ekstrand DR, Mendes FM. J Dent Res 2015;94(7):895-904. REVIEWER: Svante Twetman, DDS, PhD, Odont Dr PURPOSE...

  15. Detection of growth hormone doping by gene expression profiling of peripheral blood.

    Science.gov (United States)

    Mitchell, Christopher J; Nelson, Anne E; Cowley, Mark J; Kaplan, Warren; Stone, Glenn; Sutton, Selina K; Lau, Amie; Lee, Carol M Y; Ho, Ken K Y

    2009-12-01

    GH abuse is a significant problem in many sports, and there is currently no robust test that allows detection of doping beyond a short window after administration. Our objective was to evaluate gene expression profiling in peripheral blood leukocytes in-vivo as a test for GH doping in humans. Seven men and thirteen women were administered GH, 2 mg/d sc for 8 wk. Blood was collected at baseline and at 8 wk. RNA was extracted from the white cell fraction. Microarray analysis was undertaken using Agilent 44K G4112F arrays using a two-color design. Quantitative RT-PCR using TaqMan gene expression assays was performed for validation of selected differentially expressed genes. GH induced an approximately 2-fold increase in circulating IGF-I that was maintained throughout the 8 wk of the study. GH induced significant changes in gene expression with 353 in women and 41 in men detected with a false discovery rate of less than 5%. None of the differentially expressed genes were common between men and women. The maximal changes were a doubling for up-regulated or halving for down-regulated genes, similar in magnitude to the variation between individuals. Quantitative RT-PCR for seven target genes showed good concordance between microarray and quantitative PCR data in women but not in men. Gene expression analysis of peripheral blood leukocytes is unlikely to be a viable approach for the detection of GH doping.

  16. High-Resolution Remotely Sensed Small Target Detection by Imitating Fly Visual Perception Mechanism

    Directory of Open Access Journals (Sweden)

    Fengchen Huang

    2012-01-01

    Full Text Available The difficulty and limitation of small target detection methods for high-resolution remote sensing data have been a recent research hot spot. Inspired by the information capture and processing theory of fly visual system, this paper endeavors to construct a characterized model of information perception and make use of the advantages of fast and accurate small target detection under complex varied nature environment. The proposed model forms a theoretical basis of small target detection for high-resolution remote sensing data. After the comparison of prevailing simulation mechanism behind fly visual systems, we propose a fly-imitated visual system method of information processing for high-resolution remote sensing data. A small target detector and corresponding detection algorithm are designed by simulating the mechanism of information acquisition, compression, and fusion of fly visual system and the function of pool cell and the character of nonlinear self-adaption. Experiments verify the feasibility and rationality of the proposed small target detection model and fly-imitated visual perception method.

  17. High-resolution remotely sensed small target detection by imitating fly visual perception mechanism.

    Science.gov (United States)

    Huang, Fengchen; Xu, Lizhong; Li, Min; Tang, Min

    2012-01-01

    The difficulty and limitation of small target detection methods for high-resolution remote sensing data have been a recent research hot spot. Inspired by the information capture and processing theory of fly visual system, this paper endeavors to construct a characterized model of information perception and make use of the advantages of fast and accurate small target detection under complex varied nature environment. The proposed model forms a theoretical basis of small target detection for high-resolution remote sensing data. After the comparison of prevailing simulation mechanism behind fly visual systems, we propose a fly-imitated visual system method of information processing for high-resolution remote sensing data. A small target detector and corresponding detection algorithm are designed by simulating the mechanism of information acquisition, compression, and fusion of fly visual system and the function of pool cell and the character of nonlinear self-adaption. Experiments verify the feasibility and rationality of the proposed small target detection model and fly-imitated visual perception method.

  18. Reorganization of neural systems mediating peripheral visual selective attention in the deaf: An optical imaging study.

    Science.gov (United States)

    Seymour, Jenessa L; Low, Kathy A; Maclin, Edward L; Chiarelli, Antonio M; Mathewson, Kyle E; Fabiani, Monica; Gratton, Gabriele; Dye, Matthew W G

    2017-01-01

    Theories of brain plasticity propose that, in the absence of input from the preferred sensory modality, some specialized brain areas may be recruited when processing information from other modalities, which may result in improved performance. The Useful Field of View task has previously been used to demonstrate that early deafness positively impacts peripheral visual attention. The current study sought to determine the neural changes associated with those deafness-related enhancements in visual performance. Based on previous findings, we hypothesized that recruitment of posterior portions of Brodmann area 22, a brain region most commonly associated with auditory processing, would be correlated with peripheral selective attention as measured using the Useful Field of View task. We report data from severe to profoundly deaf adults and normal-hearing controls who performed the Useful Field of View task while cortical activity was recorded using the event-related optical signal. Behavioral performance, obtained in a separate session, showed that deaf subjects had lower thresholds (i.e., better performance) on the Useful Field of View task. The event-related optical data indicated greater activity for the deaf adults than for the normal-hearing controls during the task in the posterior portion of Brodmann area 22 in the right hemisphere. Furthermore, the behavioral thresholds correlated significantly with this neural activity. This work provides further support for the hypothesis that cross-modal plasticity in deaf individuals appears in higher-order auditory cortices, whereas no similar evidence was obtained for primary auditory areas. It is also the only neuroimaging study to date that has linked deaf-related changes in the right temporal lobe to visual task performance outside of the imaging environment. The event-related optical signal is a valuable technique for studying cross-modal plasticity in deaf humans. The non-invasive and relatively quiet characteristics of

  19. Toward unsupervised outbreak detection through visual perception of new patterns

    Directory of Open Access Journals (Sweden)

    Lévy Pierre P

    2009-06-01

    Full Text Available Abstract Background Statistical algorithms are routinely used to detect outbreaks of well-defined syndromes, such as influenza-like illness. These methods cannot be applied to the detection of emerging diseases for which no preexisting information is available. This paper presents a method aimed at facilitating the detection of outbreaks, when there is no a priori knowledge of the clinical presentation of cases. Methods The method uses a visual representation of the symptoms and diseases coded during a patient consultation according to the International Classification of Primary Care 2nd version (ICPC-2. The surveillance data are transformed into color-coded cells, ranging from white to red, reflecting the increasing frequency of observed signs. They are placed in a graphic reference frame mimicking body anatomy. Simple visual observation of color-change patterns over time, concerning a single code or a combination of codes, enables detection in the setting of interest. Results The method is demonstrated through retrospective analyses of two data sets: description of the patients referred to the hospital by their general practitioners (GPs participating in the French Sentinel Network and description of patients directly consulting at a hospital emergency department (HED. Informative image color-change alert patterns emerged in both cases: the health consequences of the August 2003 heat wave were visualized with GPs' data (but passed unnoticed with conventional surveillance systems, and the flu epidemics, which are routinely detected by standard statistical techniques, were recognized visually with HED data. Conclusion Using human visual pattern-recognition capacities to detect the onset of unexpected health events implies a convenient image representation of epidemiological surveillance and well-trained "epidemiology watchers". Once these two conditions are met, one could imagine that the epidemiology watchers could signal epidemiological alerts

  20. Dissociable Roles of Different Types of Working Memory Load in Visual Detection

    Science.gov (United States)

    Konstantinou, Nikos; Lavie, Nilli

    2013-01-01

    We contrasted the effects of different types of working memory (WM) load on detection. Considering the sensory-recruitment hypothesis of visual short-term memory (VSTM) within load theory (e.g., Lavie, 2010) led us to predict that VSTM load would reduce visual-representation capacity, thus leading to reduced detection sensitivity during maintenance, whereas load on WM cognitive control processes would reduce priority-based control, thus leading to enhanced detection sensitivity for a low-priority stimulus. During the retention interval of a WM task, participants performed a visual-search task while also asked to detect a masked stimulus in the periphery. Loading WM cognitive control processes (with the demand to maintain a random digit order [vs. fixed in conditions of low load]) led to enhanced detection sensitivity. In contrast, loading VSTM (with the demand to maintain the color and positions of six squares [vs. one in conditions of low load]) reduced detection sensitivity, an effect comparable with that found for manipulating perceptual load in the search task. The results confirmed our predictions and established a new functional dissociation between the roles of different types of WM load in the fundamental visual perception process of detection. PMID:23713796

  1. Functional visual fields: relationship of visual field areas to self-reported function.

    Science.gov (United States)

    Subhi, Hikmat; Latham, Keziah; Myint, Joy; Crossland, Michael D

    2017-07-01

    The aim of this study is to relate areas of the visual field to functional difficulties to inform the development of a binocular visual field assessment that can reflect the functional consequences of visual field loss. Fifty-two participants with peripheral visual field loss undertook binocular assessment of visual fields using the 30-2 and 60-4 SITA Fast programs on the Humphrey Field Analyser, and mean thresholds were derived. Binocular visual acuity, contrast sensitivity and near reading performance were also determined. Self-reported overall and mobility function were assessed using the Dutch ICF Activity Inventory. Greater visual field loss (0-60°) was associated with worse self-reported function both overall (R 2 = 0.50; p function (R 2 = 0.61, p function in multiple regression analyses. Superior and inferior visual field areas related similarly to mobility function (R 2 = 0.56, p function in multiple regression analysis. Mean threshold of the binocular visual field to 60° eccentricity is a good predictor of self-reported function overall, and particularly of mobility function. Both the central (0-30°) and peripheral (30-60°) mean threshold are good predictors of self-reported function, but the peripheral (30-0°) field is a slightly better predictor of mobility function, and should not be ignored when considering functional consequences of field loss. The inferior visual field is a slightly stronger predictor of perceived overall and mobility function than the superior field. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  2. Age-related changes in visual exploratory behavior in a natural scene setting.

    Science.gov (United States)

    Hamel, Johanna; De Beukelaer, Sophie; Kraft, Antje; Ohl, Sven; Audebert, Heinrich J; Brandt, Stephan A

    2013-01-01

    Diverse cognitive functions decline with increasing age, including the ability to process central and peripheral visual information in a laboratory testing situation (useful visual field of view). To investigate whether and how this influences activities of daily life, we studied age-related changes in visual exploratory behavior in a natural scene setting: a driving simulator paradigm of variable complexity was tested in subjects of varying ages with simultaneous eye- and head-movement recordings via a head-mounted camera. Detection and reaction times were also measured by visual fixation and manual reaction. We considered video computer game experience as a possible influence on performance. Data of 73 participants of varying ages were analyzed, driving two different courses. We analyzed the influence of route difficulty level, age, and eccentricity of test stimuli on oculomotor and driving behavior parameters. No significant age effects were found regarding saccadic parameters. In the older subjects head-movements increasingly contributed to gaze amplitude. More demanding courses and more peripheral stimuli locations induced longer reaction times in all age groups. Deterioration of the functionally useful visual field of view with increasing age was not suggested in our study group. However, video game-experienced subjects revealed larger saccade amplitudes and a broader distribution of fixations on the screen. They reacted faster to peripheral objects suggesting the notion of a general detection task rather than perceiving driving as a central task. As the video game-experienced population consisted of younger subjects, our study indicates that effects due to video game experience can easily be misinterpreted as age effects if not accounted for. We therefore view it as essential to consider video game experience in all testing methods using virtual media.

  3. Age-related changes in visual exploratory behavior in a natural scene setting

    Directory of Open Access Journals (Sweden)

    Johanna eHamel

    2013-06-01

    Full Text Available Diverse cognitive functions decline with increasing age, including the ability to process central and peripheral visual information in a laboratory testing situation (useful visual field of view. To investigate whether and how this influences activities of daily life, we studied age-related changes in visual exploratory behavior in a natural scene setting: a driving simulator paradigm of variable complexity was tested in subjects of varying ages with simultaneous eye- and head-movement recordings via a head-mounted camera. Detection and reaction times were also measured by visual fixation and manual reaction. We considered video computer game experience as a possible influence on performance. Data of 73 participants of varying ages were analyzed, driving two different courses. We analyzed the influence of route difficulty level, age and eccentricity of test stimuli on oculomotor and driving behavior parameters. No significant age effects were found regarding saccadic parameters. In the older subjects head-movements increasingly contributed to gaze amplitude. More demanding courses and more peripheral stimuli locations, induced longer reaction times in all age groups. Deterioration of the functionally useful visual field of view with increasing age was not suggested in our study group. However, video game-experienced subjects revealed larger saccade amplitudes and a broader distribution of fixations on the screen. They reacted faster to peripheral objects suggesting the notion of a general detection task rather than perceiving driving as a central task. As the video game experienced population consisted of younger subjects, our study indicates that effects due to video game experience can easily be misinterpreted as age effects if not accounted for. We therefore view it as essential to consider video game experience in all testing methods using virtual media.

  4. Peripheral Visual Cues: Their Fate in Processing and Effects on Attention and Temporal-Order Perception.

    Science.gov (United States)

    Tünnermann, Jan; Scharlau, Ingrid

    2016-01-01

    Peripheral visual cues lead to large shifts in psychometric distributions of temporal-order judgments. In one view, such shifts are attributed to attention speeding up processing of the cued stimulus, so-called prior entry. However, sometimes these shifts are so large that it is unlikely that they are caused by attention alone. Here we tested the prevalent alternative explanation that the cue is sometimes confused with the target on a perceptual level, bolstering the shift of the psychometric function. We applied a novel model of cued temporal-order judgments, derived from Bundesen's Theory of Visual Attention. We found that cue-target confusions indeed contribute to shifting psychometric functions. However, cue-induced changes in the processing rates of the target stimuli play an important role, too. At smaller cueing intervals, the cue increased the processing speed of the target. At larger intervals, inhibition of return was predominant. Earlier studies of cued TOJs were insensitive to these effects because in psychometric distributions they are concealed by the conjoint effects of cue-target confusions and processing rate changes.

  5. LEA Detection and Tracking Method for Color-Independent Visual-MIMO

    Directory of Open Access Journals (Sweden)

    Jai-Eun Kim

    2016-07-01

    Full Text Available Communication performance in the color-independent visual-multiple input multiple output (visual-MIMO technique is deteriorated by light emitting array (LEA detection and tracking errors in the received image because the image sensor included in the camera must be used as the receiver in the visual-MIMO system. In this paper, in order to improve detection reliability, we first set up the color-space-based region of interest (ROI in which an LEA is likely to be placed, and then use the Harris corner detection method. Next, we use Kalman filtering for robust tracking by predicting the most probable location of the LEA when the relative position between the camera and the LEA varies. In the last step of our proposed method, the perspective projection is used to correct the distorted image, which can improve the symbol decision accuracy. Finally, through numerical simulation, we show the possibility of robust detection and tracking of the LEA, which results in a symbol error rate (SER performance improvement.

  6. Polarization Calculation and Underwater Target Detection Inspired by Biological Visual Imaging

    Directory of Open Access Journals (Sweden)

    Jie Shen

    2014-04-01

    Full Text Available In challenging underwater environments, the polarization parameter maps calculated by the Stokes model are characterized by the high noise and error, harassing the underwater target detection tasks. In order to solve this problem, this paper proposes a novel bionic polarization calculation and underwater target detection method by modeling the visual system of mantis shrimps. This system includes many operators including a polarization-opposition calculation, a factor optimization and a visual neural network model. A calibration learning method is proposed to search the optimal value of the factors in the linear subtraction model. Finally, a six-channel visual neural network model is proposed to detect the underwater targets. Experimental results proved that the maps produced by the polarization-opposition parameter is more accurate and have lower noise than that produced by the Stokes parameter, achieving better performance in underwater target detection tasks.

  7. Fusion of audio and visual cues for laughter detection

    NARCIS (Netherlands)

    Petridis, Stavros; Pantic, Maja

    Past research on automatic laughter detection has focused mainly on audio-based detection. Here we present an audio- visual approach to distinguishing laughter from speech and we show that integrating the information from audio and video channels leads to improved performance over single-modal

  8. Classic Peripheral Signs of Subacute Bacterial Endocarditis

    Directory of Open Access Journals (Sweden)

    Yooyoung Chong

    2016-10-01

    Full Text Available A 50-year-old female patient with visual disturbances was referred for further evaluation of a heart murmur. Fundoscopy revealed a Roth spot in both eyes. A physical examination showed peripheral signs of infective endocarditis, including Osler nodes, Janeway lesions, and splinter hemorrhages. Our preoperative diagnosis was subacute bacterial endocarditis with severe aortic regurgitation. The patient underwent aortic valve replacement and was treated with intravenous antibiotics for 6 weeks postoperatively. The patient made a remarkable recovery and was discharged without complications. We report this case of subacute endocarditis with all 4 classic peripheral signs in a patient who presented with visual disturbance.

  9. Classic Peripheral Signs of Subacute Bacterial Endocarditis

    Science.gov (United States)

    Chong, Yooyoung; Han, Sung Joon; Rhee, Youn Ju; Kang, Shin Kwang; Yu, Jae Hyeon; Na, Myung Hoon

    2016-01-01

    A 50-year-old female patient with visual disturbances was referred for further evaluation of a heart murmur. Fundoscopy revealed a Roth spot in both eyes. A physical examination showed peripheral signs of infective endocarditis, including Osler nodes, Janeway lesions, and splinter hemorrhages. Our preoperative diagnosis was subacute bacterial endocarditis with severe aortic regurgitation. The patient underwent aortic valve replacement and was treated with intravenous antibiotics for 6 weeks postoperatively. The patient made a remarkable recovery and was discharged without complications. We report this case of subacute endocarditis with all 4 classic peripheral signs in a patient who presented with visual disturbance. PMID:27734006

  10. Slow changing postural cues cancel visual field dependence on self-tilt detection.

    Science.gov (United States)

    Scotto Di Cesare, C; Macaluso, T; Mestre, D R; Bringoux, L

    2015-01-01

    Interindividual differences influence the multisensory integration process involved in spatial perception. Here, we assessed the effect of visual field dependence on self-tilt detection relative to upright, as a function of static vs. slow changing visual or postural cues. To that aim, we manipulated slow rotations (i.e., 0.05° s(-1)) of the body and/or the visual scene in pitch. Participants had to indicate whether they felt being tilted forward at successive angles. Results show that thresholds for self-tilt detection substantially differed between visual field dependent/independent subjects, when only the visual scene was rotated. This difference was no longer present when the body was actually rotated, whatever the visual scene condition (i.e., absent, static or rotated relative to the observer). These results suggest that the cancellation of visual field dependence by dynamic postural cues may rely on a multisensory reweighting process, where slow changing vestibular/somatosensory inputs may prevail over visual inputs. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Bronchial intubation could be detected by the visual stethoscope techniques in pediatric patients.

    Science.gov (United States)

    Kimura, Tetsuro; Suzuki, Akira; Mimuro, Soichiro; Makino, Hiroshi; Sato, Shigehito

    2012-12-01

    We created a system that allows the visualization of breath sounds (visual stethoscope). We compared the visual stethoscope technique with auscultation for the detection of bronchial intubation in pediatric patients. In the auscultation group, an anesthesiologist advanced the tracheal tube, while another anesthesiologist auscultated bilateral breath sounds to detect the change and/or disappearance of unilateral breath sounds. In the visualization group, the stethoscope was used to detect changes in breath sounds and/or disappearance of unilateral breath sounds. The distance from the edge of the mouth to the carina was measured using a fiberoptic bronchoscope. Forty pediatric patients were enrolled in the study. At the point at which irregular breath sounds were auscultated, the tracheal tube was located at 0.5 ± 0.8 cm on the bronchial side from the carina. When a detectable change of shape of the visualized breath sound was observed, the tracheal tube was located 0.1 ± 1.2 cm on the bronchial side (not significant). At the point at which unilateral breath sounds were auscultated or a unilateral shape of the visualized breath sound was observed, the tracheal tube was 1.5 ± 0.8 or 1.2 ± 1.0 cm on the bronchial side, respectively (not significant). The visual stethoscope allowed to display the left and the right lung sound simultaneously and detected changes of breath sounds and unilateral breath sound as a tracheal tube was advanced. © 2012 Blackwell Publishing Ltd.

  12. Gender differences in pre-attentive change detection for visual but not auditory stimuli.

    Science.gov (United States)

    Yang, Xiuxian; Yu, Yunmiao; Chen, Lu; Sun, Hailian; Qiao, Zhengxue; Qiu, Xiaohui; Zhang, Congpei; Wang, Lin; Zhu, Xiongzhao; He, Jincai; Zhao, Lun; Yang, Yanjie

    2016-01-01

    Despite ongoing debate about gender differences in pre-attention processes, little is known about gender effects on change detection for auditory and visual stimuli. We explored gender differences in change detection while processing duration information in auditory and visual modalities. We investigated pre-attentive processing of duration information using a deviant-standard reverse oddball paradigm (50 ms/150 ms) for auditory and visual mismatch negativity (aMMN and vMMN) in males and females (n=21/group). In the auditory modality, decrement and increment aMMN were observed at 150-250 ms after the stimulus onset, and there was no significant gender effect on MMN amplitudes in temporal or fronto-central areas. In contrast, in the visual modality, only increment vMMN was observed at 180-260 ms after the onset of stimulus, and it was higher in males than in females. No gender effect was found in change detection for auditory stimuli, but change detection was facilitated for visual stimuli in males. Gender effects should be considered in clinical studies of pre-attention for visual stimuli. Copyright © 2015 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  13. Effect of ocular transverse chromatic aberration on detection acuity for peripheral vision.

    Science.gov (United States)

    Cheney, Frank; Thibos, Larry; Bradley, Arthur

    2015-01-01

    We examined the effect of transverse chromatic aberration (TCA) on detection acuity for white-light interference fringes seen in Maxwellian view at various orientations and locations in the visual field. A circular patch (3.5° diameter, 3.2 log Trolands) of nominally high-contrast fringes was produced on the retina by a commercial instrument (the Lotmar Visometer, Haag Streit) mounted on a gimbal for controlled positioning of the stimulus in the visual field from 0° to 35° eccentricity. Detection acuity for white light fringes for all meridians and eccentricities ≥15° was maximum when fringes were oriented parallel to the visual meridian line. This meridional effect disappeared when a narrow-band filter was used to eliminate TCA. The meridional effect also disappeared when the interferometric stimulator was displaced laterally to align the instrument with the eye's local achromatic axis. Modelling confirmed that TCA is the major factor responsible for white-light meridional bias, with minor contribution arising from higher-order monochromatic aberrations and neural factors. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.

  14. Wide-field fundus autofluorescence corresponds to visual fields in chorioretinitis patients

    Directory of Open Access Journals (Sweden)

    Seidensticker F

    2011-11-01

    Full Text Available Florian Seidensticker1, Aljoscha S Neubauer1, Tamer Wasfy1,2, Carmen Stumpf1, Stephan R Thurau1,*, Anselm Kampik1, Marcus Kernt1,*1Department of Ophthalmology, Ludwig-Maximilians-University, Munich, Germany; 2Department of Ophthalmology, Tanta University, Tanta, Egypt *Both authors contributed equally to this workBackground and objectives: Detection of peripheral fundus autofluorescence (FAF using conventional scanning laser ophthalmoscopes (SLOs is difficult and requires pupil dilation. Here we evaluated the diagnostic properties of wide-field FAF detected by a two-laser wavelength wide-field SLO in uveitis patients.Study design/materials and methods: Observational case series of four patients suffering from different types of posterior uveitis/chorioretinitis. Wide-field FAF images were compared to visual fields. Panretinal FAF was detected by a newly developed SLO, which allows FAF imaging of up to 200° of the retina in one scan without the need for pupil dilation. Visual fields were obtained by Goldmann manual perimetry.Results: Findings from wide-field FAF imaging showed correspondence to visual field defects in all cases.Conclusion: Wide-field FAF allowed the detection of visual field defect-related alterations of the retinal pigment epithelium in all four uveitis cases.Keywords: fundus autofluorescence (FAF, Optomap, wide-field scanning laser ophthalmoscopy, imaging, uveitis, visual field

  15. The role of peripheral vision in implicit contextual cuing.

    Science.gov (United States)

    van Asselen, Marieke; Castelo-Branco, Miguel

    2009-01-01

    Implicit contextual cuing refers to the ability to learn the association between contextual information of our environment and a specific target, which can be used to guide attention during visual search. It was recently suggested that the storage of a snapshot image of the local context of a target underlies implicit contextual cuing. To make such a snapshot, it is necessary to use peripheral vision. In order to test whether peripheral vision can underlie implicit contextual cuing, we used a covert visual search task, in which participants were required to indicate the orientation of a target stimulus while foveating a fixation cross. The response times were shorter when the configuration of the stimuli was repeated than when the configuration was new. Importantly, this effect was still found after 10 days, indicating that peripherally perceived spatial context information can be stored in memory for long periods of time. These results indicate that peripheral vision can be used to make a snapshot of the local context of a target.

  16. Catheter indwell time and phlebitis development during peripheral intravenous catheter administration.

    Science.gov (United States)

    Pasalioglu, Kadriye Burcu; Kaya, Hatice

    2014-07-01

    Intravenous catheters have been indispensable tools of modern medicine. Although intravenous applications can be used for a multitude of purposes, these applications may cause complications, some of which have serious effects. Of these complications, the most commonly observed is phlebitis. This study was conducted to determine the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. This study determined the effect of catheter indwell time on phlebitis development during peripheral intravenous catheter administration. The study included a total of 103 individuals who were administered 439 catheters and satisfied the study enrollment criteria at one infectious diseases clinic in Istanbul/Turkey. Data were compiled from Patient Information Forms, Peripheral Intravenous Catheter and Therapy Information Forms, reported grades based on the Visual Infusion Phlebitis Assessment Scale, and Peripheral Intravenous Catheter Nurse Observation Forms. The data were analyzed using SPSS. Results : The mean patient age was 53.75±15.54 (standard deviation) years, and 59.2% of the study participants were men. Phlebitis was detected in 41.2% of peripheral intravenous catheters, and the rate decreased with increased catheter indwell time. Analyses showed that catheter indwell time, antibiotic usage, sex, and catheterization sites were significantly associated with development of phlebitis. The results of this study show that catheters can be used for longer periods of time when administered under optimal conditions and with appropriate surveillance.

  17. Agnosic vision is like peripheral vision, which is limited by crowding.

    Science.gov (United States)

    Strappini, Francesca; Pelli, Denis G; Di Pace, Enrico; Martelli, Marialuisa

    2017-04-01

    Visual agnosia is a neuropsychological impairment of visual object recognition despite near-normal acuity and visual fields. A century of research has provided only a rudimentary account of the functional damage underlying this deficit. We find that the object-recognition ability of agnosic patients viewing an object directly is like that of normally-sighted observers viewing it indirectly, with peripheral vision. Thus, agnosic vision is like peripheral vision. We obtained 14 visual-object-recognition tests that are commonly used for diagnosis of visual agnosia. Our "standard" normal observer took these tests at various eccentricities in his periphery. Analyzing the published data of 32 apperceptive agnosia patients and a group of 14 posterior cortical atrophy (PCA) patients on these tests, we find that each patient's pattern of object recognition deficits is well characterized by one number, the equivalent eccentricity at which our standard observer's peripheral vision is like the central vision of the agnosic patient. In other words, each agnosic patient's equivalent eccentricity is conserved across tests. Across patients, equivalent eccentricity ranges from 4 to 40 deg, which rates severity of the visual deficit. In normal peripheral vision, the required size to perceive a simple image (e.g., an isolated letter) is limited by acuity, and that for a complex image (e.g., a face or a word) is limited by crowding. In crowding, adjacent simple objects appear unrecognizably jumbled unless their spacing exceeds the crowding distance, which grows linearly with eccentricity. Besides conservation of equivalent eccentricity across object-recognition tests, we also find conservation, from eccentricity to agnosia, of the relative susceptibility of recognition of ten visual tests. These findings show that agnosic vision is like eccentric vision. Whence crowding? Peripheral vision, strabismic amblyopia, and possibly apperceptive agnosia are all limited by crowding, making it

  18. DETECTION OF SBEM-MRNA IN PERIPHERAL BLOOD OF PATIENTS WITH BREAST CANCER AND ITS CLINICAL SIGNIFICANCE

    Institute of Scientific and Technical Information of China (English)

    YANG Hua-Wei; YANG Nan-Wu; CAO Ji; LIU Jian-Lun; ZHANG Chuan-Min; CHEN Jian-Si; JIANG Yi; OU Chao; SU Jian-Jia

    2006-01-01

    Objective: The aim of the present study is to explore the expression of a specific marker of breast cancer, small breast epithelial mucin(SBEM)mRNA, in peripheral blood and to investigate its significance. Methods: The expressions of SBEM-mRNA in peripheral blood of 67 patients with breast cancer, 16 patients with benign breast disease, and 20 normal healthy volunteers were detected with nested reverse transcription-polymerase chain reaction (Nested-RT-PCR). Results: SBEM-mRNA was negative in healthy individuals and patients with benign breast tumor, but 50.7%(34/67) of breast cancer patients showed positive expression of SBEM-mRNA in peripheral blood, of whom 25%(2/8) were in stage I, 45.8%(11/24) in stage II, 43.75%(11/24) in stage III and 73.7(14/19) in stage IV. The positive rate in stage IV was higher than that in stage I, II, III (P<0.05). Expressions of SBEM-mRNA had no correlation with age, carcinoma size, pathological type, ER and PR state (P>0.05). Conclusion: SBEM-mRNA is specifically expressed in breast cancer and it may act as a marker for the detection of micrometastasis of breast cancer.

  19. Burn-related peripheral neuropathy: A systematic review.

    Science.gov (United States)

    Tu, Yiji; Lineaweaver, William C; Zheng, Xianyou; Chen, Zenggan; Mullins, Fred; Zhang, Feng

    2017-06-01

    Peripheral neuropathy is the most frequent disabling neuromuscular complication of burns. However, the insidious and progressive onset of burn neuropathy makes it often undiagnosed or overlooked. In our study, we reviewed the current studies on the burn-related peripheral neuropathy to summarize the morbidity, mechanism, detecting method and management of peripheral neuropathy in burn patients. Of the 1533 burn patients included in our study, 98 cases (6.39%) were presented with peripheral neuropathy. Thermal and electrical burns were the most common etiologies. Surgical procedures, especially nerve decompression, showed good effect on functional recovery of both acute and delayed peripheral neuropathy in burn patients. It is noteworthy that, for early detection and prevention of peripheral neuropathy, electrodiagnostic examinations should be performed on burn patients independent of symptoms. Still, the underlying mechanisms of burn-related peripheral neuropathy remain to be clarified. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  20. Research on metallic material defect detection based on bionic sensing of human visual properties

    Science.gov (United States)

    Zhang, Pei Jiang; Cheng, Tao

    2018-05-01

    Due to the fact that human visual system can quickly lock the areas of interest in complex natural environment and focus on it, this paper proposes an eye-based visual attention mechanism by simulating human visual imaging features based on human visual attention mechanism Bionic Sensing Visual Inspection Model Method to Detect Defects of Metallic Materials in the Mechanical Field. First of all, according to the biologically visually significant low-level features, the mark of defect experience marking is used as the intermediate feature of simulated visual perception. Afterwards, SVM method was used to train the advanced features of visual defects of metal material. According to the weight of each party, the biometrics detection model of metal material defect, which simulates human visual characteristics, is obtained.

  1. Training improves reading speed in peripheral vision: is it due to attention?

    Science.gov (United States)

    Lee, Hye-Won; Kwon, Miyoung; Legge, Gordon E; Gefroh, Joshua J

    2010-06-01

    Previous research has shown that perceptual training in peripheral vision, using a letter-recognition task, increases reading speed and letter recognition (S. T. L. Chung, G. E. Legge, & S. H. Cheung, 2004). We tested the hypothesis that enhanced deployment of spatial attention to peripheral vision explains this training effect. Subjects were pre- and post-tested with 3 tasks at 10° above and below fixation-RSVP reading speed, trigram letter recognition (used to construct visual-span profiles), and deployment of spatial attention (measured as the benefit of a pre-cue for target position in a lexical-decision task). Groups of five normally sighted young adults received 4 days of trigram letter-recognition training in upper or lower visual fields, or central vision. A control group received no training. Our measure of deployment of spatial attention revealed visual-field anisotropies; better deployment of attention in the lower field than the upper, and in the lower-right quadrant compared with the other three quadrants. All subject groups exhibited slight improvement in deployment of spatial attention to peripheral vision in the post-test, but this improvement was not correlated with training-related increases in reading speed and the size of visual-span profiles. Our results indicate that improved deployment of spatial attention to peripheral vision does not account for improved reading speed and letter recognition in peripheral vision.

  2. Optical coherent tomography in diagnoses of peripheral retinal degenarations

    OpenAIRE

    O. G. Pozdeyeva; T. B. Shaimov; A. Yu. Galin; R. B. Shaimov; T. A. Shaimova; A. V. Zolotova; A. V. Fomin

    2014-01-01

    Purpose: Studying the capabilities of optical coherence tomography (RTVue-100, OPTOVUE, USA) in evaluation of peripheral retinal degenerations, vitreoretinal adhesions, adjacent vitreous body as well as measurement of morphometric data.Methods: The study included 189 patients (239 eyes) with peripheral retinal degeneration. 77 men and 112 women aged 18 to 84 underwent an ophthalmologic examination since November 2012 until October 2013. The peripheral retina was visualized with the help of op...

  3. Unconsciously perceived fear in peripheral vision alerts the limbic system: a MEG study.

    Directory of Open Access Journals (Sweden)

    Dimitri J Bayle

    Full Text Available BACKGROUND: In ecological situations, threatening stimuli often come out from the peripheral vision. Such aggressive messages must trigger rapid attention to the periphery to allow a fast and adapted motor reaction. Several clues converge to hypothesize that peripheral danger presentation can trigger off a fast arousal network potentially independent of the consciousness spot. METHODOLOGY/PRINCIPAL FINDINGS: In the present MEG study, spatio-temporal dynamics of the neural processing of danger related stimuli were explored as a function of the stimuli position in the visual field. Fearful and neutral faces were briefly presented in the central or peripheral visual field, and were followed by target faces stimuli. An event-related beamformer source analysis model was applied in three time windows following the first face presentations: 80 to 130 ms, 140 to 190 ms, and 210 to 260 ms. The frontal lobe and the right internal temporal lobe part, including the amygdala, reacted as soon as 80 ms of latency to fear occurring in the peripheral vision. For central presentation, fearful faces evoked the classical neuronal activity along the occipito-temporal visual pathway between 140 and 190 ms. CONCLUSIONS: Thus, the high spatio-temporal resolution of MEG allowed disclosing a fast response of a network involving medial temporal and frontal structures in the processing of fear related stimuli occurring unconsciously in the peripheral visual field. Whereas centrally presented stimuli are precisely processed by the ventral occipito-temporal cortex, the related-to-danger stimuli appearing in the peripheral visual field are more efficient to produce a fast automatic alert response possibly conveyed by subcortical structures.

  4. Assisting the Visually Impaired: Obstacle Detection and Warning System by Acoustic Feedback

    Directory of Open Access Journals (Sweden)

    Andrés Cela

    2012-12-01

    Full Text Available The aim of this article is focused on the design of an obstacle detection system for assisting visually impaired people. A dense disparity map is computed from the images of a stereo camera carried by the user. By using the dense disparity map, potential obstacles can be detected in 3D in indoor and outdoor scenarios. A ground plane estimation algorithm based on RANSAC plus filtering techniques allows the robust detection of the ground in every frame. A polar grid representation is proposed to account for the potential obstacles in the scene. The design is completed with acoustic feedback to assist visually impaired users while approaching obstacles. Beep sounds with different frequencies and repetitions inform the user about the presence of obstacles. Audio bone conducting technology is employed to play these sounds without interrupting the visually impaired user from hearing other important sounds from its local environment. A user study participated by four visually impaired volunteers supports the proposed system.

  5. MutScan: fast detection and visualization of target mutations by scanning FASTQ data.

    Science.gov (United States)

    Chen, Shifu; Huang, Tanxiao; Wen, Tiexiang; Li, Hong; Xu, Mingyan; Gu, Jia

    2018-01-22

    Some types of clinical genetic tests, such as cancer testing using circulating tumor DNA (ctDNA), require sensitive detection of known target mutations. However, conventional next-generation sequencing (NGS) data analysis pipelines typically involve different steps of filtering, which may cause miss-detection of key mutations with low frequencies. Variant validation is also indicated for key mutations detected by bioinformatics pipelines. Typically, this process can be executed using alignment visualization tools such as IGV or GenomeBrowse. However, these tools are too heavy and therefore unsuitable for validating mutations in ultra-deep sequencing data. We developed MutScan to address problems of sensitive detection and efficient validation for target mutations. MutScan involves highly optimized string-searching algorithms, which can scan input FASTQ files to grab all reads that support target mutations. The collected supporting reads for each target mutation will be piled up and visualized using web technologies such as HTML and JavaScript. Algorithms such as rolling hash and bloom filter are applied to accelerate scanning and make MutScan applicable to detect or visualize target mutations in a very fast way. MutScan is a tool for the detection and visualization of target mutations by only scanning FASTQ raw data directly. Compared to conventional pipelines, this offers a very high performance, executing about 20 times faster, and offering maximal sensitivity since it can grab mutations with even one single supporting read. MutScan visualizes detected mutations by generating interactive pile-ups using web technologies. These can serve to validate target mutations, thus avoiding false positives. Furthermore, MutScan can visualize all mutation records in a VCF file to HTML pages for cloud-friendly VCF validation. MutScan is an open source tool available at GitHub: https://github.com/OpenGene/MutScan.

  6. Contingent capture of involuntary visual attention interferes with detection of auditory stimuli.

    Science.gov (United States)

    Kamke, Marc R; Harris, Jill

    2014-01-01

    The involuntary capture of attention by salient visual stimuli can be influenced by the behavioral goals of an observer. For example, when searching for a target item, irrelevant items that possess the target-defining characteristic capture attention more strongly than items not possessing that feature. Such contingent capture involves a shift of spatial attention toward the item with the target-defining characteristic. It is not clear, however, if the associated decrements in performance for detecting the target item are entirely due to involuntary orienting of spatial attention. To investigate whether contingent capture also involves a non-spatial interference, adult observers were presented with streams of visual and auditory stimuli and were tasked with simultaneously monitoring for targets in each modality. Visual and auditory targets could be preceded by a lateralized visual distractor that either did, or did not, possess the target-defining feature (a specific color). In agreement with the contingent capture hypothesis, target-colored distractors interfered with visual detection performance (response time and accuracy) more than distractors that did not possess the target color. Importantly, the same pattern of results was obtained for the auditory task: visual target-colored distractors interfered with sound detection. The decrement in auditory performance following a target-colored distractor suggests that contingent capture involves a source of processing interference in addition to that caused by a spatial shift of attention. Specifically, we argue that distractors possessing the target-defining characteristic enter a capacity-limited, serial stage of neural processing, which delays detection of subsequently presented stimuli regardless of the sensory modality.

  7. Contingent capture of involuntary visual attention interferes with detection of auditory stimuli

    Directory of Open Access Journals (Sweden)

    Marc R. Kamke

    2014-06-01

    Full Text Available The involuntary capture of attention by salient visual stimuli can be influenced by the behavioral goals of an observer. For example, when searching for a target item, irrelevant items that possess the target-defining characteristic capture attention more strongly than items not possessing that feature. Such contingent capture involves a shift of spatial attention toward the item with the target-defining characteristic. It is not clear, however, if the associated decrements in performance for detecting the target item are entirely due to involuntary orienting of spatial attention. To investigate whether contingent capture also involves a non-spatial interference, adult observers were presented with streams of visual and auditory stimuli and were tasked with simultaneously monitoring for targets in each modality. Visual and auditory targets could be preceded by a lateralized visual distractor that either did, or did not, possess the target-defining feature (a specific color. In agreement with the contingent capture hypothesis, target-colored distractors interfered with visual detection performance (response time and accuracy more than distractors that did not possess the target color. Importantly, the same pattern of results was obtained for the auditory task: visual target-colored distractors interfered with sound detection. The decrement in auditory performance following a target-colored distractor suggests that contingent capture involves a source of processing interference in addition to that caused by a spatial shift of attention. Specifically, we argue that distractors possessing the target-defining characteristic enter a capacity-limited, serial stage of neural processing, which delays detection of subsequently presented stimuli regardless of the sensory modality.

  8. A visual stethoscope to detect the position of the tracheal tube.

    Science.gov (United States)

    Kato, Hiromi; Suzuki, Akira; Nakajima, Yoshiki; Makino, Hiroshi; Sanjo, Yoshimitsu; Nakai, Takayoshi; Shiraishi, Yoshito; Katoh, Takasumi; Sato, Shigehito

    2009-12-01

    Advancing a tracheal tube into the bronchus produces unilateral breath sounds. We created a Visual Stethoscope that allows real-time fast Fourier transformation of the sound signal and 3-dimensional (frequency-amplitude-time) color rendering of the results on a personal computer with simultaneous processing of 2 individual sound signals. The aim of this study was to evaluate whether the Visual Stethoscope can detect bronchial intubation in comparison with auscultation. After induction of general anesthesia, the trachea was intubated with a tracheal tube. The distance from the incisors to the carina was measured using a fiberoptic bronchoscope. While the anesthesiologist advanced the tracheal tube from the trachea to the bronchus, another anesthesiologist auscultated breath sounds to detect changes of the breath sounds and/or disappearance of bilateral breath sounds for every 1 cm that the tracheal tube was advanced. Two precordial stethoscopes placed at the left and right sides of the chest were used to record breath sounds simultaneously. Subsequently, at a later date, we randomly entered the recorded breath sounds into the Visual Stethoscope. The same anesthesiologist observed the visualized breath sounds on the personal computer screen processed by the Visual Stethoscope to examine changes of breath sounds and/or disappearance of bilateral breath sound. We compared the decision made based on auscultation with that made based on the results of the visualized breath sounds using the Visual Stethoscope. Thirty patients were enrolled in the study. When irregular breath sounds were auscultated, the tip of the tracheal tube was located at 0.6 +/- 1.2 cm on the bronchial side of the carina. Using the Visual Stethoscope, when there were any changes of the shape of the visualized breath sound, the tube was located at 0.4 +/- 0.8 cm on the tracheal side of the carina (P Stethoscope (not significant). During advancement of the tracheal tube, alterations of the shape of the

  9. Application of PCR-based DNA sequencing technique for the detection of Leptospira in peripheral blood of septicemia patients

    OpenAIRE

    Ram, S.; Vimalin, J.M.; Jambulingam, M.; Tiru, V.; Gopalakrishnan, R.K.; Madhavan, H.N.

    2012-01-01

    Aim: Isolation, dark field detection and microscopic agglutination test (MAT) are considered ―gold standard‖ tests for diagnosis of Leptospirosis. Several PCR assays are reported but very few have been evaluated for detection of Leptospirosis. Therefore, this study was undertaken. This study aims to design and standardize polymerase chain reaction (PCR) - based DNA sequencing technique for the detection of pathogenic Leptospira from peripheral blood of patients clinically diagnosed with septi...

  10. Perceptual load in different regions of the visual scene and its relevance for driving.

    Science.gov (United States)

    Marciano, Hadas; Yeshurun, Yaffa

    2015-06-01

    The aim of this study was to better understand the role played by perceptual load, at both central and peripheral regions of the visual scene, in driving safety. Attention is a crucial factor in driving safety, and previous laboratory studies suggest that perceptual load is an important factor determining the efficiency of attentional selectivity. Yet, the effects of perceptual load on driving were never studied systematically. Using a driving simulator, we orthogonally manipulated the load levels at the road (central load) and its sides (peripheral load), while occasionally introducing critical events at one of these regions. Perceptual load affected driving performance at both regions of the visual scene. Critically, the effect was different for central versus peripheral load: Whereas load levels on the road mainly affected driving speed, load levels on its sides mainly affected the ability to detect critical events initiating from the roadsides. Moreover, higher levels of peripheral load impaired performance but mainly with low levels of central load, replicating findings with simple letter stimuli. Perceptual load has a considerable effect on driving, but the nature of this effect depends on the region of the visual scene at which the load is introduced. Given the observed importance of perceptual load, authors of future studies of driving safety should take it into account. Specifically, these findings suggest that our understanding of factors that may be relevant for driving safety would benefit from studying these factors under different levels of load at different regions of the visual scene. © 2014, Human Factors and Ergonomics Society.

  11. Detection of Intracellular Factor VIII Protein in Peripheral Blood Mononuclear Cells by Flow Cytometry

    Directory of Open Access Journals (Sweden)

    Gouri Shankar Pandey

    2013-01-01

    Full Text Available Flow cytometry is widely used in cancer research for diagnosis, detection of minimal residual disease, as well as immune monitoring and profiling following immunotherapy. Detection of specific host proteins for diagnosis predominantly uses quantitative PCR and western blotting assays. In this study, we optimized a flow cytometry-based detection assay for Factor VIII protein in peripheral blood mononuclear cells (PBMCs. An indirect intracellular staining (ICS method was standardized using monoclonal antibodies to different domains of human Factor VIII protein. The FVIII protein expression level was estimated by calculating the mean and median fluorescence intensities (MFI values for each monoclonal antibody. ICS staining of transiently transfected cell lines supported the method's specificity. Intracellular FVIII protein expression was also detected by the monoclonal antibodies used in the study in PBMCs of five blood donors. In summary, our data suggest that intracellular FVIII detection in PBMCs of hemophilia A patients can be a rapid and reliable method to detect intracellular FVIII levels.

  12. Clinical significance of the molecular detection of melanoma cells circulating in the peripheral blood in melanoma patients.

    Science.gov (United States)

    Konstantopoulos, K; Psatha, M; Kalotychou, V; Frangia, N; Ioannovits, I; Meletis, I; Loukopoulos, D

    2001-06-01

    Blood circulating melanoma cells may be important for the spread of the disease. The current methods are not sensitive in detecting micro metastases. Tyrosinase mRNA can be detected in peripheral blood by a molecular test. As tyrosinase is expressed only in melanocytes and melanocytes normally do not circulate in the blood, the test may prove reliable in detecting circulating melanoma cells. we used a reverse-transcription polymerase chain reaction (RT-PCR) detecting tyrosinase mRNA in the blood. A prospective investigation in melanoma patients undergoing surgery was conducted; follow-up duration was 12 months. University Department Laboratory and Melanoma Clinic of a Tertiary Hospital. a total of 27 Greek patients with a diagnosis of malignant melanoma at different stages of the disease; 12 months follow-up after surgery. Samples form 12 healthy volunteers and 13 patients with chronic myelogenous leukemia served as controls. none. none. We detected mRNA tyrosinase in the peripheral blood in 16 out of 27 melanoma patients studied. No tyrosinase mRNA was detected in any of the 25 samples from the controls. Two of the 16 positive cases developed a metastasis within the next 12 months following testing. The other 14 positive cases remain metastasis free for this period, as also did the test negative cases. Detection of blood circulating melanoma cells by a RT-PCR technique, may be helpful in defining melanoma patients who are at risk for the spread of the disease.

  13. Angle observation of laser peripheral iridoplasty for the treatment of acute angle-closure glaucoma which could not be controlled by drugs

    Directory of Open Access Journals (Sweden)

    Wei Han

    2013-07-01

    Full Text Available AIM: To evaluate the effect of laser peripheral iridoplasty(LPIPto treat acute angle-closure glaucoma(AACGwhich could not controlled by drugs and with persistent ocular hypertension. METHODS: Totally 67 patients(69 eyeswith AACG were performed LPIP when intraocular pressure(IOPwas still over 30mmHg after the medicine therapy for 3-6 hours. Visual acuity and intraocular pressure were under detection before laser treatment and 30 minutes, 60 minutes and 2 hours after laser treatment. We measured the anterior chamber depth, width of angle, iris thickness with ultrasound biomicroscope(UBM. Dynamic gonioscopy was used to evaluate the degree of peripheral anterior synechia(PAS.RESULTS: Angle open distance(AODafter iridoplasty was increased(PPF=151.79, PCONCLUSION: LPIP can deepen peripheral anterior chamber, increase the angle access and lower the IOP immediately. It is an important ongoing adjuvant treatment, which can reduce the patients suffering by lowering the IOP quickly, reduce the damage of visual function caused by long-term high intraocular pressure, avoid side effect of the drugs, and can improve the prognosis.

  14. Electrochemical skin conductance to detect sudomotor dysfunction, peripheral neuropathy and the risk of foot ulceration among Saudi patients with diabetes mellitus.

    Science.gov (United States)

    Sheshah, Eman; Madanat, Amal; Al-Greesheh, Fahad; Al-Qaisi, Dalal; Al-Harbi, Mohammad; Aman, Reem; Al-Ghamdi, Abdul Aziz; Al-Madani, Khaled

    2015-01-01

    Sudomotor dysfunction is manifested clinically as abnormal sweating leading to dryness of feet skin and increased risk of foot ulceration. The aim of this study was to test the performance of foot electrochemical skin conductance (ESC) to detect diabetic peripheral neuropathy and the risk of foot ulceration against traditional methods in Saudi patients with diabetes mellitus. This cross-sectional study was conducted on 296 Saudi patients with diabetes mellitus. Painful neuropathic symptoms were evaluated using the neuropathy symptom score (NSS). The risk of foot ulceration and diabetic peripheral neuropathy were determined using the neuropathy disability score (NDS). Vibration perception threshold (VPT) was assessed using neurothesiometer. Neurophysiological assessment of the right and left sural, peroneal and tibial nerves was performed in 222 participants. Diabetic peripheral neuropathy was defined according to the definition of the American Academy of Neurology. ESC was measured with Sudoscan. Feet-ESC decreased as the scores of sensory and motor function tests increased. Feet-ESC decreased as the NSS, NDS and severity of diabetic peripheral neuropathy increased. Sensitivity of feet-ESC peripheral neuropathy assessed by VPT ≥ 25 V, NDS ≥ 3, NDS ≥ 6 was 90.1, 61 and 63.8 % respectively and specificity 77, 85 and 81.9 % respectively. Sensitivity of feet-ESC peripheral neuropathy assessed by VPT ≥ 25 V, NDS ≥ 3, NDS ≥ 6 was 100, 80.6 and 80.9 % respectively. Sensitivity and specificity of feet-ESC peripheral neuropathy were 67.5 and 58.9 % respectively. Sudoscan a simple and objective tool can be used to detect diabetic peripheral neuropathy and the risk of foot ulceration among patients with diabetes mellitus. Prospective studies to confirm our results are warranted.

  15. Information theoretic analysis of canny edge detection in visual communication

    Science.gov (United States)

    Jiang, Bo; Rahman, Zia-ur

    2011-06-01

    In general edge detection evaluation, the edge detectors are examined, analyzed, and compared either visually or with a metric for specific an application. This analysis is usually independent of the characteristics of the image-gathering, transmission and display processes that do impact the quality of the acquired image and thus, the resulting edge image. We propose a new information theoretic analysis of edge detection that unites the different components of the visual communication channel and assesses edge detection algorithms in an integrated manner based on Shannon's information theory. The edge detection algorithm here is considered to achieve high performance only if the information rate from the scene to the edge approaches the maximum possible. Thus, by setting initial conditions of the visual communication system as constant, different edge detection algorithms could be evaluated. This analysis is normally limited to linear shift-invariant filters so in order to examine the Canny edge operator in our proposed system, we need to estimate its "power spectral density" (PSD). Since the Canny operator is non-linear and shift variant, we perform the estimation for a set of different system environment conditions using simulations. In our paper we will first introduce the PSD of the Canny operator for a range of system parameters. Then, using the estimated PSD, we will assess the Canny operator using information theoretic analysis. The information-theoretic metric is also used to compare the performance of the Canny operator with other edge-detection operators. This also provides a simple tool for selecting appropriate edgedetection algorithms based on system parameters, and for adjusting their parameters to maximize information throughput.

  16. Immunohistochemical Analysis in the Rat Central Nervous System and Peripheral Lymph Node Tissue Sections.

    Science.gov (United States)

    Adzemovic, Milena Z; Zeitelhofer, Manuel; Leisser, Marianne; Köck, Ulricke; Kury, Angela; Olsson, Tomas

    2016-11-14

    Immunohistochemistry (IHC) provides highly specific, reliable and attractive protein visualization. Correct performance and interpretation of an IHC-based multicolor labeling is challenging, especially when utilized for assessing interrelations between target proteins in the tissue with a high fat content such as the central nervous system (CNS). Our protocol represents a refinement of the standard immunolabeling technique particularly adjusted for detection of both structural and soluble proteins in the rat CNS and peripheral lymph nodes (LN) affected by neuroinflammation. Nonetheless, with or without further modifications, our protocol could likely be used for detection of other related protein targets, even in other organs and species than here presented.

  17. Automatic Detection and Visualization of Qualitative Hemodynamic Characteristics in Cerebral Aneurysms.

    Science.gov (United States)

    Gasteiger, R; Lehmann, D J; van Pelt, R; Janiga, G; Beuing, O; Vilanova, A; Theisel, H; Preim, B

    2012-12-01

    Cerebral aneurysms are a pathological vessel dilatation that bear a high risk of rupture. For the understanding and evaluation of the risk of rupture, the analysis of hemodynamic information plays an important role. Besides quantitative hemodynamic information, also qualitative flow characteristics, e.g., the inflow jet and impingement zone are correlated with the risk of rupture. However, the assessment of these two characteristics is currently based on an interactive visual investigation of the flow field, obtained by computational fluid dynamics (CFD) or blood flow measurements. We present an automatic and robust detection as well as an expressive visualization of these characteristics. The detection can be used to support a comparison, e.g., of simulation results reflecting different treatment options. Our approach utilizes local streamline properties to formalize the inflow jet and impingement zone. We extract a characteristic seeding curve on the ostium, on which an inflow jet boundary contour is constructed. Based on this boundary contour we identify the impingement zone. Furthermore, we present several visualization techniques to depict both characteristics expressively. Thereby, we consider accuracy and robustness of the extracted characteristics, minimal visual clutter and occlusions. An evaluation with six domain experts confirms that our approach detects both hemodynamic characteristics reasonably.

  18. Visual function, driving safety, and the elderly.

    Science.gov (United States)

    Keltner, J L; Johnson, C A

    1987-09-01

    The authors have conducted a survey of the Departments of Motor Vehicles in all 50 states, the District of Columbia, and Puerto Rico requesting information about the visual standards, accidents, and conviction rates for different age groups. In addition, we have reviewed the literature on visual function and traffic safety. Elderly drivers have a greater number of vision problems that affect visual acuity and/or peripheral visual fields. Although the elderly are responsible for a small percentage of the total number of traffic accidents, the types of accidents they are involved in (e.g., failure to yield the right-of-way, intersection collisions, left turns onto crossing streets) may be related to peripheral and central visual field problems. Because age-related changes in performance occur at different rates for various individuals, licensing of the elderly driver should be based on functional abilities rather than age. Based on information currently available, we can make the following recommendations: (1) periodic evaluations of visual acuity and visual fields should be performed every 1 to 2 years in the population over age 65; (2) drivers of any age with multiple accidents or moving violations should have visual acuity and visual fields evaluated; and (3) a system should be developed for physicians to report patients with potentially unsafe visual function. The authors believe that these recommendations may help to reduce the number of traffic accidents that result from peripheral visual field deficits.

  19. Adaptive Gaze Strategies for Locomotion with Constricted Visual Field

    Directory of Open Access Journals (Sweden)

    Colas N. Authié

    2017-07-01

    Full Text Available In retinitis pigmentosa (RP, loss of peripheral visual field accounts for most difficulties encountered in visuo-motor coordination during locomotion. The purpose of this study was to accurately assess the impact of peripheral visual field loss on gaze strategies during locomotion, and identify compensatory mechanisms. Nine RP subjects presenting a central visual field limited to 10–25° in diameter, and nine healthy subjects were asked to walk in one of three directions—straight ahead to a visual target, leftward and rightward through a door frame, with or without obstacle on the way. Whole body kinematics were recorded by motion capture, and gaze direction in space was reconstructed using an eye-tracker. Changes in gaze strategies were identified in RP subjects, including extensive exploration prior to walking, frequent fixations of the ground (even knowing no obstacle was present, of door edges, essentially of the proximal one, of obstacle edge/corner, and alternating door edges fixations when approaching the door. This was associated with more frequent, sometimes larger rapid-eye-movements, larger movements, and forward tilting of the head. Despite the visual handicap, the trajectory geometry was identical between groups, with a small decrease in walking speed in RPs. These findings identify the adaptive changes in sensory-motor coordination, in order to ensure visual awareness of the surrounding, detect changes in spatial configuration, collect information for self-motion, update the postural reference frame, and update egocentric distances to environmental objects. They are of crucial importance for the design of optimized rehabilitation procedures.

  20. Adaptive Gaze Strategies for Locomotion with Constricted Visual Field

    Science.gov (United States)

    Authié, Colas N.; Berthoz, Alain; Sahel, José-Alain; Safran, Avinoam B.

    2017-01-01

    In retinitis pigmentosa (RP), loss of peripheral visual field accounts for most difficulties encountered in visuo-motor coordination during locomotion. The purpose of this study was to accurately assess the impact of peripheral visual field loss on gaze strategies during locomotion, and identify compensatory mechanisms. Nine RP subjects presenting a central visual field limited to 10–25° in diameter, and nine healthy subjects were asked to walk in one of three directions—straight ahead to a visual target, leftward and rightward through a door frame, with or without obstacle on the way. Whole body kinematics were recorded by motion capture, and gaze direction in space was reconstructed using an eye-tracker. Changes in gaze strategies were identified in RP subjects, including extensive exploration prior to walking, frequent fixations of the ground (even knowing no obstacle was present), of door edges, essentially of the proximal one, of obstacle edge/corner, and alternating door edges fixations when approaching the door. This was associated with more frequent, sometimes larger rapid-eye-movements, larger movements, and forward tilting of the head. Despite the visual handicap, the trajectory geometry was identical between groups, with a small decrease in walking speed in RPs. These findings identify the adaptive changes in sensory-motor coordination, in order to ensure visual awareness of the surrounding, detect changes in spatial configuration, collect information for self-motion, update the postural reference frame, and update egocentric distances to environmental objects. They are of crucial importance for the design of optimized rehabilitation procedures. PMID:28798674

  1. Visual SLAM and Moving-object Detection for a Small-size Humanoid Robot

    Directory of Open Access Journals (Sweden)

    Yin-Tien Wang

    2010-09-01

    Full Text Available In the paper, a novel moving object detection (MOD algorithm is developed and integrated with robot visual Simultaneous Localization and Mapping (vSLAM. The moving object is assumed to be a rigid body and its coordinate system in space is represented by a position vector and a rotation matrix. The MOD algorithm is composed of detection of image features, initialization of image features, and calculation of object coordinates. Experimentation is implemented on a small-size humanoid robot and the results show that the performance of the proposed algorithm is efficient for robot visual SLAM and moving object detection.

  2. Visual functions and disability in diabetic retinopathy patients.

    Science.gov (United States)

    Shrestha, Gauri Shankar; Kaiti, Raju

    2014-01-01

    This study was undertaken to find correlations between visual functions and visual disabilities in patients with diabetic retinopathy. A cross-sectional study was carried out among 38 visually impaired diabetic retinopathy subjects at the Low Vision Clinic of B.P. Koirala Lions Centre for Ophthalmic Studies, Kathmandu. The subjects underwent assessment of distance and near visual acuity, objective and subjective refraction, contrast sensitivity, color vision, and central and peripheral visual fields. The visual disabilities of each subject in their daily lives were evaluated using a standard questionnaire. Multiple regression analysis between visual functions and visual disabilities index was assessed. The majority of subjects (42.1%) were of the age group 60-70 years. Best corrected visual acuity was found to be 0.73±0.2 in the better eye and 0.93±0.27 in the worse eye, which was significantly different at p=0.002. Visual disability scores were significantly higher for legibility of letters (1.2±0.3) and sentences (1.4±0.4), and least for clothing (0.7±0.3). Visual disability index for legibility of letters and sentences was significantly correlated with near visual acuity and peripheral visual field. Contrast sensitivity was also significantly correlated with the visual disability index, and total scores. Impairment of near visual acuity, contrast sensitivity, and peripheral visual field correlated significantly with different types of visual disability. Hence, these clinical tests should be an integral part of the visual assessment of diabetic eyes. Copyright © 2013 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  3. Visual functions and disability in diabetic retinopathy patients

    Directory of Open Access Journals (Sweden)

    Gauri Shankar Shrestha

    2014-01-01

    Conclusion: Impairment of near visual acuity, contrast sensitivity, and peripheral visual field correlated significantly with different types of visual disability. Hence, these clinical tests should be an integral part of the visual assessment of diabetic eyes.

  4. Application of blood-pool agents in visualization of peripheral vessels

    International Nuclear Information System (INIS)

    Giovagnoni, A.; Catalano, C.

    2007-01-01

    Effective arterial imaging is essential in patients with peripheral arterial disease (PAD) in whom a revascularization procedure is planned. Digital subtraction angiography (DSA) has traditionally been regarded as the gold standard for imaging in peripheral arterial disease, but this technique is subject to certain limitations, such as the risks of adverse reactions associated with arterial catheterization and iodinated contrast agents. Contrast-enhanced magnetic resonance angiography is now recommended as an effective and useful imaging technique in peripheral arterial disease, since it offers high enhanced contrast between blood and stationary tissue and fast acquisition times. However, extracellular gadolinium contrast agents rapidly diffuse into the interstitial spaces, and thus are suitable only for first-pass imaging. This limitation can be overcome by the use of blood-pool (intravascular) contrast agents, such as gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany), which are retained within the blood vessels and hence facilitate both first-pass and steady-state imaging with high spatial resolution. Blood-pool agents, therefore, offer improved imaging, particularly of distal vessels, compared with extracellular contrast agents. Examples of first-pass and steady-state imaging with gadofosveset are presented. (orig.)

  5. A novel visual saliency detection method for infrared video sequences

    Science.gov (United States)

    Wang, Xin; Zhang, Yuzhen; Ning, Chen

    2017-12-01

    Infrared video applications such as target detection and recognition, moving target tracking, and so forth can benefit a lot from visual saliency detection, which is essentially a method to automatically localize the ;important; content in videos. In this paper, a novel visual saliency detection method for infrared video sequences is proposed. Specifically, for infrared video saliency detection, both the spatial saliency and temporal saliency are considered. For spatial saliency, we adopt a mutual consistency-guided spatial cues combination-based method to capture the regions with obvious luminance contrast and contour features. For temporal saliency, a multi-frame symmetric difference approach is proposed to discriminate salient moving regions of interest from background motions. Then, the spatial saliency and temporal saliency are combined to compute the spatiotemporal saliency using an adaptive fusion strategy. Besides, to highlight the spatiotemporal salient regions uniformly, a multi-scale fusion approach is embedded into the spatiotemporal saliency model. Finally, a Gestalt theory-inspired optimization algorithm is designed to further improve the reliability of the final saliency map. Experimental results demonstrate that our method outperforms many state-of-the-art saliency detection approaches for infrared videos under various backgrounds.

  6. Multivariate Functional Data Visualization and Outlier Detection

    KAUST Repository

    Dai, Wenlin

    2017-03-19

    This article proposes a new graphical tool, the magnitude-shape (MS) plot, for visualizing both the magnitude and shape outlyingness of multivariate functional data. The proposed tool builds on the recent notion of functional directional outlyingness, which measures the centrality of functional data by simultaneously considering the level and the direction of their deviation from the central region. The MS-plot intuitively presents not only levels but also directions of magnitude outlyingness on the horizontal axis or plane, and demonstrates shape outlyingness on the vertical axis. A dividing curve or surface is provided to separate non-outlying data from the outliers. Both the simulated data and the practical examples confirm that the MS-plot is superior to existing tools for visualizing centrality and detecting outliers for functional data.

  7. Multivariate Functional Data Visualization and Outlier Detection

    KAUST Repository

    Dai, Wenlin; Genton, Marc G.

    2017-01-01

    This article proposes a new graphical tool, the magnitude-shape (MS) plot, for visualizing both the magnitude and shape outlyingness of multivariate functional data. The proposed tool builds on the recent notion of functional directional outlyingness, which measures the centrality of functional data by simultaneously considering the level and the direction of their deviation from the central region. The MS-plot intuitively presents not only levels but also directions of magnitude outlyingness on the horizontal axis or plane, and demonstrates shape outlyingness on the vertical axis. A dividing curve or surface is provided to separate non-outlying data from the outliers. Both the simulated data and the practical examples confirm that the MS-plot is superior to existing tools for visualizing centrality and detecting outliers for functional data.

  8. Remote sensing image ship target detection method based on visual attention model

    Science.gov (United States)

    Sun, Yuejiao; Lei, Wuhu; Ren, Xiaodong

    2017-11-01

    The traditional methods of detecting ship targets in remote sensing images mostly use sliding window to search the whole image comprehensively. However, the target usually occupies only a small fraction of the image. This method has high computational complexity for large format visible image data. The bottom-up selective attention mechanism can selectively allocate computing resources according to visual stimuli, thus improving the computational efficiency and reducing the difficulty of analysis. Considering of that, a method of ship target detection in remote sensing images based on visual attention model was proposed in this paper. The experimental results show that the proposed method can reduce the computational complexity while improving the detection accuracy, and improve the detection efficiency of ship targets in remote sensing images.

  9. Pre-visual detection of stress in pine forests

    Science.gov (United States)

    Olson, C. E., Jr.

    1977-01-01

    Pre-visual, or early, detection of forest stress with particular reference to detection of attacks by pine bark beetles is discussed. Preliminary efforts to obtain early detection of attacks by pine bark beetles, using MSS data from the ERIM M-7 scanner, were not sufficiently successful to demonstrate an operational capability, but indicate that joint processing of the 0.71 to 0.73, 2.00 to 2.60, and 9.3 to 11.7 micrometer bands holds some promise. Ratio processing of transformed data from the 0.45 to 0.52, 1.55 to 2.60, and 4.5 to 5.5 or 9.3 to 11.7 micrometer regions appears even more promising.

  10. A new measure for the assessment of visual awareness in individuals with tunnel vision.

    Science.gov (United States)

    AlSaqr, Ali M; Dickinson, Chris M

    2017-01-01

    Individuals with a restricted peripheral visual field or tunnel vision (TV) have problems moving about and avoiding obstacles. Some individuals adapt better than others and some use assistive optical aids, so measurement of the visual field is not sufficient to describe their performance. In the present study, we developed a new clinical test called the 'Assessment of Visual Awareness (AVA)', which can be used to measure detection of peripheral targets. The participants were 20 patients with TV due to retinitis pigmentosa (PTV) and 50 normally sighted participants with simulated tunnel vision (STV) using goggles. In the AVA test, detection times were measured, when subjects searched for 24 individually presented, one degree targets, randomly positioned in a 60 degrees noise background. Head and eye movements were allowed and the presentation time was unlimited. The test validity was investigated by correlating the detection times with the 'percentage of preferred walking speed' (PPWS) and the 'number of collisions' on an indoor mobility course. In PTV and STV, the detection times had significant negative correlation with the field of view. The detection times had significant positive relations with target location. In the STV, the detection time was significantly negatively correlated with the PPWS and significantly positively correlated with the collisions score on the indoor mobility course. In the PTV, the relationship was not statistically significant. No significant difference in performance of STV was found when repeating the test one to two weeks later. The proposed AVA test was sensitive to the field of view and target location. The test is unique in design, quick, simple to deliver and both repeatable and valid. It could be a valuable tool to test different rehabilitation strategies in patients with TV. © 2016 Optometry Australia.

  11. Peripheral Venous Waveform Analysis for Detecting Hemorrhage and Iatrogenic Volume Overload in a Porcine Model.

    Science.gov (United States)

    Hocking, Kyle M; Sileshi, Ban; Baudenbacher, Franz J; Boyer, Richard B; Kohorst, Kelly L; Brophy, Colleen M; Eagle, Susan S

    2016-10-01

    Unrecognized hemorrhage and unguided resuscitation is associated with increased perioperative morbidity and mortality. The authors investigated peripheral venous waveform analysis (PIVA) as a method for quantitating hemorrhage as well as iatrogenic fluid overload during resuscitation. The authors conducted a prospective study on Yorkshire Pigs (n = 8) undergoing hemorrhage, autologous blood return, and administration of balanced crystalloid solution beyond euvolemia. Intra-arterial blood pressure, electrocardiogram, and pulse oximetry were applied to each subject. Peripheral venous pressure was measured continuously through an upper extremity standard peripheral IV catheter and analyzed with LabChart. The primary outcome was comparison of change in the first fundamental frequency (f1) of PIVA with standard and invasive monitoring and shock index (SI). Hemorrhage, return to euvolemia, and iatrogenic fluid overload resulted in significantly non-zero slopes of f1 amplitude. There were no significant differences in heart rate or mean arterial pressure, and a late change in SI. For the detection of hypovolemia the PIVA f1 amplitude change generated an receiver operator curves (ROC) curve with an area under the curve (AUC) of 0.93; heart rate AUC = 0.61; mean arterial pressure AUC = 0.48, and SI AUC = 0.72. For hypervolemia the f1 amplitude generated an ROC curve with an AUC of 0.85, heart rate AUC = 0.62, mean arterial pressure AUC = 0.63, and SI AUC = 0.65. In this study, PIVA demonstrated a greater sensitivity for detecting acute hemorrhage, return to euvolemia, and iatrogenic fluid overload compared with standard monitoring and SI. PIVA may provide a low-cost, minimally invasive monitoring solution for monitoring and resuscitating patients with perioperative hemorrhage.

  12. Dual-energy CT based vascular iodine analysis improves sensitivity for peripheral pulmonary artery thrombus detection: An experimental study in canines

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Chun Xiang [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu 210002 (China); Zhang, Long Jiang, E-mail: kevinzhlj@163.com [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu 210002 (China); Han, Zong Hong; Zhou, Chang Sheng [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu 210002 (China); Krazinski, Aleksander W.; Silverman, Justin R. [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu 210002 (China); Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Lu, Guang Ming, E-mail: cjr.luguangming@vip.163.com [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu 210002 (China)

    2013-12-01

    Purpose: To evaluate the performance of dual-energy CT (DECT) based vascular iodine analysis for the detection of acute peripheral pulmonary thrombus (PE) in a canine model with histopathological findings as the reference standard. Materials and methods: The study protocol was approved by our institutional animal committee. Thrombi (n = 12) or saline (n = 4) were intravenously injected via right femoral vein in sixteen dogs, respectively. CT pulmonary angiography (CTPA) in DECT mode was performed and conventional CTPA images and DECT based vascular iodine studies using Lung Vessels application were reconstructed. Two radiologists visually evaluated the number and location of PEs using conventional CTPA and DECT series on a per-animal and a per-clot basis. Detailed histopathological examination of lung specimens and catheter angiography served as reference standard. Sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) of DECT and CTPA were calculated on a segmental and subsegmental or more distal pulmonary artery basis. Weighted κ values were computed to evaluate inter-modality and inter-reader agreement. Results: Thirteen dogs were enrolled for final image analysis (experimental group = 9, control group = 4). Histopathological results revealed 237 emboli in 45 lung lobes in 9 experimental dogs, 11 emboli in segmental pulmonary arteries, 49 in subsegmental pulmonary arteries, 177 in fifth-order or more distal pulmonary arteries. Overall sensitivity, specificity, accuracy, PPV, and NPV for CTPA plus DECT were 93.1%, 76.9%, 87.8%, 89.4%, and 84.2% for the detection of pulmonary emboli. With CTPA versus DECT, sensitivities, specificities, accuracies, PPVs, and NPVs are all 100% for the detection of pulmonary emboli on a segmental pulmonary artery basis, 88.9%, 100%, 96.0%, 100%, and 94.1% for CTPA and 90.4%, 93.0%, 92.0%, 88.7%, and 94.1% for DECT on a subsegmental pulmonary artery basis; 23.8%, 96.4%, 50.4%, 93

  13. Creating social presence through peripheral awareness

    NARCIS (Netherlands)

    Ruyter, de B.E.R.; Huijnen, C.A.G.J.; Markopoulos, P.; IJsselsteijn, W.A.; Stephanidis, C.; Jacko, J.

    2003-01-01

    This paper describes an experimental assessment of affective user benefits that may result from peripheral awareness of a remote friend or group of friends during a shared viewing of a televised event. The experiment suggests that awareness supported through a visual display enhances the level of

  14. Evaluation of anatomical and visual function for early detection of ethambutol toxicity among tuberculosis patients

    Directory of Open Access Journals (Sweden)

    Jessica Mani Penny Tevaraj

    2017-11-01

    Full Text Available AIM: To evaluate if early ethambutol toxicity can be detected by comparing pre-and post-treatment anatomical and visual function using retinal nerve fiber thickness, pattern visual evoked potentials and conventional optic nerve function tests.METHODS:This was a prospective study involving 72 eyes of 36 patients treated with ethambutol according to directly observed treatment short-course(DOTSstrategy in Hospital Universiti Sains Malaysia, Kelantan, Malaysia. The visual acuity and optic nerve function tests were performed by a single investigator. Likewise, Humphrey automated perimetry, optical coherence tomography(OCTmeasurement of the retinal nerve fibre layer(RNFLand pattern visual evoked potential(PVEPwere performed by a single technician. The examinations were performed before initiating ethambutol treatment and 3mo after that.RESULTS: There was no change in visual acuity, colour vision, light brightness, red saturation and fundus findings pre and post ethambutol. However, there was a statistically significant deterioration in the mean deviation of the visual field post treatment(P=0.010. There were also significant changes on OCT and PVEP, with increased RNFL thickness in all quadrants(PPCONCLUSION: Ethambutol toxicity is a known complication of tuberculosis treatment. Early detection of this toxicity may prevent severe irreversible visual loss. The use of OCT to detect RNFL thickness and PVEP to assess P100 latency and amplitude can assist in the detection of subclinical anatomical and visual function changes prior to development of abnormalities on conventional optic nerve function tests.

  15. Optical coherent tomography in diagnoses of peripheral retinal degenarations

    Directory of Open Access Journals (Sweden)

    O. G. Pozdeyeva

    2013-01-01

    Full Text Available Purpose: Studying the capabilities of optical coherence tomography (RTVue-100, OPTOVUE, USA in evaluation of peripheral retinal degenerations, vitreoretinal adhesions, adjacent vitreous body as well as measurement of morphometric data.Methods: The study included 189 patients (239 eyes with peripheral retinal degeneration. 77 men and 112 women aged 18 to 84 underwent an ophthalmologic examination since November 2012 until October 2013. The peripheral retina was visualized with the help of optical coherence tomography («RTVue-100,» USA. The fundography was carried out using a Nikon NF505‑AF (Japan fundus camera. All patients were examined with a Goldmann lens.Results: Optical coherence tomography was used to evaluate different kinds of peripheral retinal degenerations, such as lattice and snail track degeneration, isolated retinal tears, cystoid retinal degeneration, pathological hyperpigmentation, retinoschisis and cobblestone degeneration. The following morphometric data were studied: dimensions of the lesion (average length, retinal thickness along the edge of the lesion, retinal thickness at the base of the lesion and the vitreoretinal interface.Conclusion: Optical coherence tomography is a promising in vivo visualization method which is useful in evaluation of peripheral retinal degenerations, vitreoretinal adhesions and tractions. It also provides a comprehensive protocolling system and monitoring. It will enable ophthalmologists to better define laser and surgical treatment indications and evaluate therapy effectiveness.

  16. Optical coherent tomography in diagnoses of peripheral retinal degenarations

    Directory of Open Access Journals (Sweden)

    O. G. Pozdeyeva

    2014-07-01

    Full Text Available Purpose: Studying the capabilities of optical coherence tomography (RTVue-100, OPTOVUE, USA in evaluation of peripheral retinal degenerations, vitreoretinal adhesions, adjacent vitreous body as well as measurement of morphometric data.Methods: The study included 189 patients (239 eyes with peripheral retinal degeneration. 77 men and 112 women aged 18 to 84 underwent an ophthalmologic examination since November 2012 until October 2013. The peripheral retina was visualized with the help of optical coherence tomography («RTVue-100,» USA. The fundography was carried out using a Nikon NF505‑AF (Japan fundus camera. All patients were examined with a Goldmann lens.Results: Optical coherence tomography was used to evaluate different kinds of peripheral retinal degenerations, such as lattice and snail track degeneration, isolated retinal tears, cystoid retinal degeneration, pathological hyperpigmentation, retinoschisis and cobblestone degeneration. The following morphometric data were studied: dimensions of the lesion (average length, retinal thickness along the edge of the lesion, retinal thickness at the base of the lesion and the vitreoretinal interface.Conclusion: Optical coherence tomography is a promising in vivo visualization method which is useful in evaluation of peripheral retinal degenerations, vitreoretinal adhesions and tractions. It also provides a comprehensive protocolling system and monitoring. It will enable ophthalmologists to better define laser and surgical treatment indications and evaluate therapy effectiveness.

  17. Tactile detection of slip: surface microgeometry and peripheral neural codes.

    Science.gov (United States)

    Srinivasan, M A; Whitehouse, J M; LaMotte, R H

    1990-06-01

    1. The role of the microgeometry of planar surfaces in the detection of sliding of the surfaces on human and monkey fingerpads was investigated. By the use of a servo-controlled tactile stimulator to press and stroke glass plates on passive fingerpads of human subjects, the ability of humans to discriminate the direction of skin stretch caused by friction and to detect the sliding motion (slip) of the plates with or without micrometer-sized surface features was determined. To identify the associated peripheral neural codes, evoked responses to the same stimuli were recorded from single, low-threshold mechanoreceptive afferent fibers innervating the fingerpads of anesthetized macaque monkeys. 2. Humans could not detect the slip of a smooth glass plate on the fingerpad. However, the direction of skin stretch was perceived based on the information conveyed by the slowly adapting afferents that respond differentially to the stretch directions. Whereas the direction of skin stretch signaled the direction of impending slip, the perception of relative motion between the plate and the finger required the existence of detectable surface features. 3. Barely detectable micrometer-sized protrusions on smooth surfaces led to the detection of slip of these surfaces, because of the exclusive activation of rapidly adapting fibers of either the Meissner (RA) or the Pacinian (PC) type to specific geometries of the microfeatures. The motion of a smooth plate with a very small single raised dot (4 microns high, 550 microns diam) caused the sequential activation of neighboring RAs along the dot path, thus providing a reliable spatiotemporal code. The stroking of the plate with a fine homogeneous texture composed of a matrix of dots (1 microns high, 50 microns diam, and spaced at 100 microns center-to-center) induced vibrations in the fingerpad that activated only the PCs and resulted in an intensive code. 4. The results show that surprisingly small features on smooth surfaces are

  18. Real-Time Lane Detection on Suburban Streets Using Visual Cue Integration

    Directory of Open Access Journals (Sweden)

    Shehan Fernando

    2014-04-01

    Full Text Available The detection of lane boundaries on suburban streets using images obtained from video constitutes a challenging task. This is mainly due to the difficulties associated with estimating the complex geometric structure of lane boundaries, the quality of lane markings as a result of wear, occlusions by traffic, and shadows caused by road-side trees and structures. Most of the existing techniques for lane boundary detection employ a single visual cue and will only work under certain conditions and where there are clear lane markings. Also, better results are achieved when there are no other on-road objects present. This paper extends our previous work and discusses a novel lane boundary detection algorithm specifically addressing the abovementioned issues through the integration of two visual cues. The first visual cue is based on stripe-like features found on lane lines extracted using a two-dimensional symmetric Gabor filter. The second visual cue is based on a texture characteristic determined using the entropy measure of the predefined neighbourhood around a lane boundary line. The visual cues are then integrated using a rule-based classifier which incorporates a modified sequential covering algorithm to improve robustness. To separate lane boundary lines from other similar features, a road mask is generated using road chromaticity values estimated from CIE L*a*b* colour transformation. Extraneous points around lane boundary lines are then removed by an outlier removal procedure based on studentized residuals. The lane boundary lines are then modelled with Bezier spline curves. To validate the algorithm, extensive experimental evaluation was carried out on suburban streets and the results are presented.

  19. Mouse V1 population correlates of visual detection rely on heterogeneity within neuronal response patterns

    Science.gov (United States)

    Montijn, Jorrit S; Goltstein, Pieter M; Pennartz, Cyriel MA

    2015-01-01

    Previous studies have demonstrated the importance of the primary sensory cortex for the detection, discrimination, and awareness of visual stimuli, but it is unknown how neuronal populations in this area process detected and undetected stimuli differently. Critical differences may reside in the mean strength of responses to visual stimuli, as reflected in bulk signals detectable in functional magnetic resonance imaging, electro-encephalogram, or magnetoencephalography studies, or may be more subtly composed of differentiated activity of individual sensory neurons. Quantifying single-cell Ca2+ responses to visual stimuli recorded with in vivo two-photon imaging, we found that visual detection correlates more strongly with population response heterogeneity rather than overall response strength. Moreover, neuronal populations showed consistencies in activation patterns across temporally spaced trials in association with hit responses, but not during nondetections. Contrary to models relying on temporally stable networks or bulk signaling, these results suggest that detection depends on transient differentiation in neuronal activity within cortical populations. DOI: http://dx.doi.org/10.7554/eLife.10163.001 PMID:26646184

  20. Recognizing Visual and Auditory Cues in the Detection of Foreign-Language Anxiety

    Science.gov (United States)

    Gregersen, Tammy

    2009-01-01

    This study examines whether nonverbal visual and/or auditory channels are more effective in detecting foreign-language anxiety. Recent research suggests that language teachers are often able to successfully decode the nonverbal behaviors indicative of foreign-language anxiety; however, relatively little is known about whether visual and/or…

  1. Mobile phone generated vibrations used to detect diabetic peripheral neuropathy.

    Science.gov (United States)

    May, Jonathan David; Morris, Matthew William John

    2017-12-01

    In the current United Kingdom population the incidence of diabetic peripheral neuropathy is increasing. The presence of diabetic neuropathy affects decision making and treatment options. This study seeks to evaluate if the vibrations generated from a mobile phone can be used to screen patients for diabetic peripheral neuropathy. This study comprised of 61 patients; a control group of 21 patients; a lower limb injury group of 19 patients; a diabetic peripheral neuropathy group of 21 patients. The control and injury group were recruited randomly from fracture clinics. The diabetic peripheral neuropathy group were randomly recruited from the diabetic foot clinic. The 61 patients were examined using a 10g Semmes-Weinstein monofilament, a 128Hz tuning fork and a vibrating mobile phone. The points tested were, index finger, patella, lateral malleoli, medial malleoli, heel, first and fifth metatarsal heads. The most accurate location of all the clinical tests was the head of the 1st metatarsal at 0.86. The overall accuracy of the tuning fork was 0.77, the ten gram monofilament 0.79 and the mobile phone accuracy was 0.88. The control group felt 420 of 441 tests (95%). The injury group felt 349 of 399 tests (87%). The neuropathic group felt 216 of 441 tests (48%). There is a significant difference in the number of tests felt between the control and both the injury and neuropathic groups. pperipheral neuropathy. The most accurate location to test for diabetic peripheral neuropathy is the head of the 1st metatarsal. Screening for diabetic peripheral neuropathy in the index finger and patella were inaccurate. An injury to the lower limb affects the patient's vibration sensation, we would therefore recommend screening the contralateral limb to the injury. This study represents level II evidence of a new diagnostic investigation. Copyright © 2016 European Foot and Ankle Society. All rights reserved.

  2. Involvement of the visual change detection process in facilitating perceptual alternation in the bistable image.

    Science.gov (United States)

    Urakawa, Tomokazu; Bunya, Mao; Araki, Osamu

    2017-08-01

    A bistable image induces one of two perceptual alternatives. When the bistable visual image is continuously viewed, the percept of the image alternates from one possible percept to the other. Perceptual alternation was previously reported to be induced by an exogenous perturbation in the bistable image, and this perturbation was theoretically interpreted to cause neural noise, prompting a transition between two stable perceptual states. However, little is known experimentally about the visual processing of exogenously driven perceptual alternation. Based on the findings of a previous behavioral study (Urakawa et al. in Perception 45:474-482, 2016), the present study hypothesized that the automatic visual change detection process, which is relevant to the detection of a visual change in a sequence of visual events, has an enhancing effect on the induction of perceptual alternation, similar to neural noise. In order to clarify this issue, we developed a novel experimental paradigm in which visual mismatch negativity (vMMN), an electroencephalographic brain response that reflects visual change detection, was evoked while participants continuously viewed the bistable image. In terms of inter-individual differences in neural and behavioral data, we found that enhancements in the peak amplitude of vMMN1, early vMMN at a latency of approximately 150 ms, correlated with increases in the proportion of perceptual alternation across participants. Our results indicate the involvement of automatic visual change detection in the induction of perceptual alternation, similar to neural noise, thereby providing a deeper insight into the neural mechanisms underlying exogenously driven perceptual alternation in the bistable image.

  3. Perception of linear horizontal self-motion induced by peripheral vision /linearvection/ - Basic characteristics and visual-vestibular interactions

    Science.gov (United States)

    Berthoz, A.; Pavard, B.; Young, L. R.

    1975-01-01

    The basic characteristics of the sensation of linear horizontal motion have been studied. Objective linear motion was induced by means of a moving cart. Visually induced linear motion perception (linearvection) was obtained by projection of moving images at the periphery of the visual field. Image velocity and luminance thresholds for the appearance of linearvection have been measured and are in the range of those for image motion detection (without sensation of self motion) by the visual system. Latencies of onset are around 1 sec and short term adaptation has been shown. The dynamic range of the visual analyzer as judged by frequency analysis is lower than the vestibular analyzer. Conflicting situations in which visual cues contradict vestibular and other proprioceptive cues show, in the case of linearvection a dominance of vision which supports the idea of an essential although not independent role of vision in self motion perception.

  4. Compact Polarimetric SAR Ship Detection with m-δ Decomposition Using Visual Attention Model

    Directory of Open Access Journals (Sweden)

    Lu Xu

    2016-09-01

    Full Text Available A few previous studies have illustrated the potentials of compact polarimetric Synthetic Aperture Radar (CP SAR in ship detection. In this paper, we design a ship detection algorithm of CP SAR from the perspective of computer vision. A ship detection algorithm using the pulsed cosine transform (PCT visual attention model is proposed to suppress background clutter and highlight conspicuous ship targets. It is the first time that a visual attention model is introduced to CP SAR application. The proposed algorithm is a quick and complete framework for practical use. Polarimetric features—the relative phase δ and volume scattering component—are extracted from m-δ decomposition to eliminate false alarms and modify the PCT model. The constant false alarm rate (CFAR algorithm based on lognormal distribution is adopted to detect ship targets, after a clutter distribution fitting procedure of the modified saliency map. The proposed method is then tested on three simulated circular-transmit-linear-receive (CTLR mode images, which covering East Sea of China. Compared with the detection results of SPAN and the saliency map with only single-channel amplitude, the proposed method achieves the highest detection rates and the lowest misidentification rate and highest figure of merit, proving the effectiveness of polarimetric information of compact polarimetric SAR ship detection and the enhancement from the visual attention model.

  5. Breaking Snake Camouflage: Humans Detect Snakes More Accurately than Other Animals under Less Discernible Visual Conditions.

    Science.gov (United States)

    Kawai, Nobuyuki; He, Hongshen

    2016-01-01

    Humans and non-human primates are extremely sensitive to snakes as exemplified by their ability to detect pictures of snakes more quickly than those of other animals. These findings are consistent with the Snake Detection Theory, which hypothesizes that as predators, snakes were a major source of evolutionary selection that favored expansion of the visual system of primates for rapid snake detection. Many snakes use camouflage to conceal themselves from both prey and their own predators, making it very challenging to detect them. If snakes have acted as a selective pressure on primate visual systems, they should be more easily detected than other animals under difficult visual conditions. Here we tested whether humans discerned images of snakes more accurately than those of non-threatening animals (e.g., birds, cats, or fish) under conditions of less perceptual information by presenting a series of degraded images with the Random Image Structure Evolution technique (interpolation of random noise). We find that participants recognize mosaic images of snakes, which were regarded as functionally equivalent to camouflage, more accurately than those of other animals under dissolved conditions. The present study supports the Snake Detection Theory by showing that humans have a visual system that accurately recognizes snakes under less discernible visual conditions.

  6. Breaking Snake Camouflage: Humans Detect Snakes More Accurately than Other Animals under Less Discernible Visual Conditions.

    Directory of Open Access Journals (Sweden)

    Nobuyuki Kawai

    Full Text Available Humans and non-human primates are extremely sensitive to snakes as exemplified by their ability to detect pictures of snakes more quickly than those of other animals. These findings are consistent with the Snake Detection Theory, which hypothesizes that as predators, snakes were a major source of evolutionary selection that favored expansion of the visual system of primates for rapid snake detection. Many snakes use camouflage to conceal themselves from both prey and their own predators, making it very challenging to detect them. If snakes have acted as a selective pressure on primate visual systems, they should be more easily detected than other animals under difficult visual conditions. Here we tested whether humans discerned images of snakes more accurately than those of non-threatening animals (e.g., birds, cats, or fish under conditions of less perceptual information by presenting a series of degraded images with the Random Image Structure Evolution technique (interpolation of random noise. We find that participants recognize mosaic images of snakes, which were regarded as functionally equivalent to camouflage, more accurately than those of other animals under dissolved conditions. The present study supports the Snake Detection Theory by showing that humans have a visual system that accurately recognizes snakes under less discernible visual conditions.

  7. Drosophila increase exploration after visually detecting predators.

    Directory of Open Access Journals (Sweden)

    Miguel de la Flor

    Full Text Available Novel stimuli elicit behaviors that are collectively known as specific exploration. These behaviors allow the animal to become more familiar with the novel objects within its environment. Specific exploration is frequently suppressed by defensive reactions to predator cues. Herein, we examine if this suppression occurs in Drosophila melanogaster by measuring the response of these flies to wild harvested predators. The flies used in our experiments have been cultured and had not lived under predator threat for multiple decades. In a circular arena with centrally-caged predators, wild type Drosophila actively avoided the pantropical jumping spider, Plexippus paykulli, and the Texas unicorn mantis, Phyllovates chlorophaena, indicating an innate defensive reaction to these predators. Interestingly, wild type Drosophila males also avoided a centrally-caged mock spider, and the avoidance of the mock spider became exaggerated when it was made to move within the cage. Visually impaired Drosophila failed to detect and avoid the Plexippus paykulli and the moving mock spider, while the broadly anosmic orco2 mutants were fully capable of detecting and avoiding Plexippus paykulli, indicating that these flies principally relied upon vison to perceive the predator stimuli. During early exploration of the arena, exploratory activity increased in the presence of Plexippus paykulli and the moving mock spider. The elevated activity induced by Plexippus paykulli disappeared after the fly had finished exploring, suggesting the flies were capable of habituating the predator cues. Taken together, these results indicate that despite being isolated from predators for decades Drosophila will visually detect these predators, retain innate defensive behaviors, respond by increasing exploratory activity in the arena rather than suppressing activity, and may habituate to normal predator cues.

  8. Prism therapy and visual rehabilitation in homonymous visual field loss.

    LENUS (Irish Health Repository)

    O'Neill, Evelyn C

    2012-02-01

    PURPOSE: Homonymous visual field defects (HVFD) are common and frequently occur after cerebrovascular accidents. They significantly impair visual function and cause disability particularly with regard to visual exploration. The purpose of this study was to assess a novel interventional treatment of monocular prism therapy on visual functioning in patients with HVFD of varied etiology using vision targeted, health-related quality of life (QOL) questionnaires. Our secondary aim was to confirm monocular and binocular visual field expansion pre- and posttreatment. METHODS: Twelve patients with acquired, documented HVFD were eligible to be included. All patients underwent specific vision-targeted, health-related QOL questionnaire and monocular and binocular Goldmann perimetry before commencing prism therapy. Patients were fitted with monocular prisms on the side of the HVFD with the base-in the direction of the field defect creating a peripheral optical exotropia and field expansion. After the treatment period, QOL questionnaires and perimetry were repeated. RESULTS: Twelve patients were included in the treatment group, 10 of whom were included in data analysis. Overall, there was significant improvement within multiple vision-related, QOL functioning parameters, specifically within the domains of general health (p < 0.01), general vision (p < 0.05), distance vision (p < 0.01), peripheral vision (p < 0.05), role difficulties (p < 0.05), dependency (p < 0.05), and social functioning (p < 0.05). Visual field expansion was shown when measured monocularly and binocularly during the study period in comparison with pretreatment baselines. CONCLUSIONS: Patients with HVFD demonstrate decreased QOL. Monocular sector prisms can improve the QOL and expand the visual field in these patients.

  9. [THE COMPARISON OF RESULTS OF DETECTION OF MINIMAL RESIDUAL DISEASE IN PERIPHERAL BLOOD AND MARROW IN CHILDREN OF THE FIRST YEAR OF LIFE WITH ACUTE LYMPHOBLASTIC LEUCOSIS].

    Science.gov (United States)

    Tsaur, G A; Riger, T O; Popov, A M; Nasedkina, T V; Kustanovich, A M; Solodovnikov, A G; Streneva, O V; Shorikov, E V; Tsvirenko, S V; Saveliev, L I; Fechina, L G

    2015-04-01

    The occurrence of minimal residual disease is an important prognostic factor under acute lymphoblastic leucosis in children and adults. In overwhelming majority of research studies bone marrow is used to detect minimal residual disease. The comparative characteristic of detection of minimal residual disease in peripheral blood and bone marrow was carried out. The prognostic role of occurrence of minimal residual disease in peripheral blood and bone marrow under therapy according protocol MLL-Baby was evaluated. The analysis embraced 142 pair samples from 53 patients with acute lymphoblastic leucosis and various displacements of gene MLL younger than 365 days. The minimal residual disease was detected by force of identification of chimeric transcripts using polymerase chain reaction in real-time mode in 7 sequential points of observation established by protocol of therapy. The comparability of results of qualitative detection of minimal residual disease in bone marrow and peripheral blood amounted to 84.5%. At that, in all 22 (15.5%) discordant samples minimal residual disease was detected only in bone marrow. Despite of high level of comparability of results of detection of minimal residual disease in peripheral blood and bone marrow the occurrence of minimal residual disease in peripheral blood at various stages of therapy demonstrated no independent prognostic significance. The established differences had no relationship with sensitivity of method determined by value of absolute expression of gene ABL. Most likely, these differences reflected real distribution of tumor cells. The results of study demonstrated that application of peripheral blood instead of bone marrow for monitoring of minimal residual disease under acute lymphoblastic leucosis in children of first year of life is inappropriate. At the same time, retention of minimal residual disease in TH4 in bone marrow was an independent and prognostic unfavorable factor under therapy of acute lymphoblastic

  10. Night-Time Vehicle Detection Algorithm Based on Visual Saliency and Deep Learning

    Directory of Open Access Journals (Sweden)

    Yingfeng Cai

    2016-01-01

    Full Text Available Night vision systems get more and more attention in the field of automotive active safety field. In this area, a number of researchers have proposed far-infrared sensor based night-time vehicle detection algorithm. However, existing algorithms have low performance in some indicators such as the detection rate and processing time. To solve this problem, we propose a far-infrared image vehicle detection algorithm based on visual saliency and deep learning. Firstly, most of the nonvehicle pixels will be removed with visual saliency computation. Then, vehicle candidate will be generated by using prior information such as camera parameters and vehicle size. Finally, classifier trained with deep belief networks will be applied to verify the candidates generated in last step. The proposed algorithm is tested in around 6000 images and achieves detection rate of 92.3% and processing time of 25 Hz which is better than existing methods.

  11. In vivo chicken model for peripheral intravascular human fibrin clot detection

    International Nuclear Information System (INIS)

    Hui, K.Y.

    1988-01-01

    A chicken model was prepared that provides a simple and economical method of evaluating the use of fibrin-specific monoclonal antibody 64C5 in the detection of peripheral vascular thrombi. Human fibrin was clotted in segments of a chicken's femoral artery and vein prior to intravenous injection of radioiodinated antibody 64C5. After a 3-hr perfusion time, the thrombosed and contralateral control segments of the vessels were excised and counted for radioactivity. The radiolabeled 64C5 uptake ratio of the thrombosed segment to the control segment was 5.4 +/- 1.2 (p less than 0.007) in the femoral artery, and 3.8 +/- 1.1 (p less than 0.02) in the femoral vein. This in vivo chicken model may also find application in studies of targeting agents for human fibrin

  12. Uncertainty of a detected spatial cluster in 1D: quantification and visualization

    KAUST Repository

    Lee, Junho; Gangnon, Ronald E.; Zhu, Jun; Liang, Jingjing

    2017-01-01

    Spatial cluster detection is an important problem in a variety of scientific disciplines such as environmental sciences, epidemiology and sociology. However, there appears to be very limited statistical methodology for quantifying the uncertainty of a detected cluster. In this paper, we develop a new method for the quantification and visualization of uncertainty associated with a detected cluster. Our approach is defining a confidence set for the true cluster and visualizing the confidence set, based on the maximum likelihood, in time or in one-dimensional space. We evaluate the pivotal property of the statistic used to construct the confidence set and the coverage rate for the true cluster via empirical distributions. For illustration, our methodology is applied to both simulated data and an Alaska boreal forest dataset. Copyright © 2017 John Wiley & Sons, Ltd.

  13. Uncertainty of a detected spatial cluster in 1D: quantification and visualization

    KAUST Repository

    Lee, Junho

    2017-10-19

    Spatial cluster detection is an important problem in a variety of scientific disciplines such as environmental sciences, epidemiology and sociology. However, there appears to be very limited statistical methodology for quantifying the uncertainty of a detected cluster. In this paper, we develop a new method for the quantification and visualization of uncertainty associated with a detected cluster. Our approach is defining a confidence set for the true cluster and visualizing the confidence set, based on the maximum likelihood, in time or in one-dimensional space. We evaluate the pivotal property of the statistic used to construct the confidence set and the coverage rate for the true cluster via empirical distributions. For illustration, our methodology is applied to both simulated data and an Alaska boreal forest dataset. Copyright © 2017 John Wiley & Sons, Ltd.

  14. Reduced visual surround suppression in schizophrenia shown by measuring contrast detection thresholds

    Directory of Open Access Journals (Sweden)

    Ignacio eSerrano-Pedraza

    2014-12-01

    Full Text Available Visual perception in schizophrenia is attracting a broad interest given the deep knowledge that we have about the visual system in healthy population. In visual science it is known that the visibility of a grating located in the visual periphery is impaired by the presence of a surrounding grating of the same spatial frequency and orientation. Previous studies have suggested abnormal visual surround suppression in patients with schizophrenia. Given that schizophrenia patients have cortical alterations including hypofunction of NMDA receptors and reduced concentration of GABA neurotransmitter, which affect lateral inhibitory connections, then they should perform better than controls in visual suppression tasks. We tested this hypothesis by measuring contrast detection thresholds using a new stimulus configuration. We tested two groups: 21 schizophrenia patients and 24 healthy subjects. Thresholds were obtained using Bayesian staircases in a 4AFC detection task where the target was a grating within a 3 deg Butterworth window that appeared in one of four possible positions at 5 deg eccentricity. We compared three conditions, a target with no surround (NS, b target on top of a surrounding grating of 20 deg diameter and 25% contrast with same spatial frequency and orthogonal orientation (OS, and c target on top of a surrounding grating with parallel (same orientation (PS. Our results show significantly lower thresholds for controls than for patients in NS and OS conditions. We also found significant lower suppression ratios PS/NS in patients. Our results support the hypothesis that inhibitory lateral connections in early visual cortex are impaired in schizophrenia patients.

  15. Ultrasound Guidance as a Rescue Technique for Peripheral Intravenous Cannulation

    National Research Council Canada - National Science Library

    Pappas, Nancy L; Michaud, Terese E; Wolbers, Russell M; Steward, James C; Fevurly, Thomas A; Samolitis, Timothy J; Shoneboom, Bruce A; Watts, Dorraine D

    2006-01-01

    Peripheral intravenous (W) cannulation can be difficult to perform using the traditional landmark or visual/palpation technique in patients with access difficulties such as deep, sclerotic, small, or fragile veins...

  16. Peripheral blood volume influenced by various external factors

    Energy Technology Data Exchange (ETDEWEB)

    Ittner, A; Scheibe, J; Stoll, W [Friedrich-Schiller-Universitaet, Jena (German Democratic Republic). Bereich Medizin

    1982-01-01

    The dependence of the peripheral blood volume upon various exogenous factors was studied in male sports students using /sup 113m/InCl. The results obtained revealed that whole-body exertions and local muscular activity produce an increase of the blood volume in the lower extremities associated with increased blood circulation. The passive measures applied caused also an increase of the blood volume, but not in all of the subjects examined. Isometric concentrations led to a highly significant reduction of the peripheral blood volume. The scintigraphic method for the visualization of the blood volume in peripheral regions of the body can be regarded as suitable for the study of hemodynamics and for the substantiation of the efficiency of measures promoting restoration.

  17. Correlation of Michigan neuropathy screening instrument, United Kingdom screening test and electrodiagnosis for early detection of diabetic peripheral neuropathy.

    Science.gov (United States)

    Fateh, Hamid R; Madani, Seyed Pezhman; Heshmat, Ramin; Larijani, Bagher

    2015-01-01

    Almost half of Diabetic Peripheral Neuropathies (DPNs) are symptom-free. Methods including questionnaires and electrodiagnosis (EDx) can be fruitful for easy reach to early diagnosis, correct treatments of diabetic neuropathy, and so decline of complications for instance diabetic foot ulcer and prevention of high costs. The goal of our study was to compare effectiveness of the Michigan neuropathy screening instrument (MNSI), United Kingdom screening test (UKST) and electrophysiological evaluation in confirming diabetic peripheral neuropathy. One hundred twenty five known diabetes mellitus male and female subjects older than 18 with or without symptoms of neuropathy comprised in this research. All of them were interviewed in terms of demographic data, lipid profile, HbA1C, duration of disease, and history of retinopathy, so examined by Michigan neuropathy screening instrument (MNSI), United Kingdom screening test (UKST), and nerve conduction studies (NCS). The collected data were analyzed by SPSS software 18. One hundred twenty five diabetic patients (70 female, 55 male) were recruited in this study with a mean age of 58.7 ± 10.2, and mean duration of diabetes was 10.17 ± 6.9 years. The mean neuropathy score of MNSI and UKST were 2.3 (1.7) and 4.16 (2.9), respectively. Each instrument detected the peripheral neuropathy in 78 (69 %) and 91 (73 %) of patients, respectively. There was a significant relationship between number of neuropathies and mean of diabetes duration and development of retinopathy in both questionnaire evaluations and NCS. By nerve conduction study, neuropathy was detected in 121 (97 %) diabetic patients were reported in order 15 (12 %) mononeuropathy (as 33 % sensory and 67 % motor neuropathy) and 106 (85 %) polyneuropathy (as 31 % motor and 69 % sensorimotor neuropathy). As regards NCS is an objective, simple, and non-invasive tool and also can determine level of damage and regeneration in peripheral nerves, this study

  18. The role of hemifield sector analysis in multifocal visual evoked potential objective perimetry in the early detection of glaucomatous visual field defects

    Directory of Open Access Journals (Sweden)

    Mousa MF

    2013-05-01

    Full Text Available Mohammad F Mousa,1 Robert P Cubbidge,2 Fatima Al-Mansouri,1 Abdulbari Bener3,41Department of Ophthalmology, Hamad Medical Corporation, Doha, Qatar; 2School of Life and Health Sciences, Aston University, Birmingham, UK; 3Department of Medical Statistics and Epidemiology, Hamad Medical Corporation, Department of Public Health, Weill Cornell Medical College, Doha, Qatar; 4Department Evidence for Population Health Unit, School of Epidemiology and Health Sciences, University of Manchester, Manchester, UKObjective: The purpose of this study was to examine the effectiveness of a new analysis method of mfVEP objective perimetry in the early detection of glaucomatous visual field defects compared to the gold standard technique.Methods and patients: Three groups were tested in this study; normal controls (38 eyes, glaucoma patients (36 eyes, and glaucoma suspect patients (38 eyes. All subjects underwent two standard 24-2 visual field tests: one with the Humphrey Field Analyzer and a single mfVEP test in one session. Analysis of the mfVEP results was carried out using the new analysis ­protocol: the hemifield sector analysis protocol.Results: Analysis of the mfVEP showed that the signal to noise ratio (SNR difference between superior and inferior hemifields was statistically significant between the three groups (analysis of variance, P < 0.001 with a 95% confidence interval, 2.82, 2.89 for normal group; 2.25, 2.29 for glaucoma suspect group; 1.67, 1.73 for glaucoma group. The difference between superior and inferior hemifield sectors and hemi-rings was statistically significant in 11/11 pair of sectors and hemi-rings in the glaucoma patients group (t-test P < 0.001, statistically significant in 5/11 pairs of sectors and hemi-rings in the glaucoma suspect group (t-test P < 0.01, and only 1/11 pair was statistically significant (t-test P < 0.9. The sensitivity and specificity of the hemifield sector analysis protocol in detecting glaucoma was 97% and 86

  19. Normal and sonographic anatomy of selected peripheral nerves. Part III: Peripheral nerves of the lower limb.

    Science.gov (United States)

    Kowalska, Berta; Sudoł-Szopińska, Iwona

    2012-06-01

    The ultrasonographic examination is currently increasingly used in imaging peripheral nerves, serving to supplement the physical examination, electromyography and magnetic resonance imaging. As in the case of other USG imaging studies, the examination of peripheral nerves is non-invasive and well-tolerated by patients. The typical ultrasonographic picture of peripheral nerves as well as the examination technique have been discussed in part I of this article series, following the example of the median nerve. Part II of the series presented the normal anatomy and the technique for examining the peripheral nerves of the upper limb. This part of the article series focuses on the anatomy and technique for examining twelve normal peripheral nerves of the lower extremity: the iliohypogastric and ilioinguinal nerves, the lateral cutaneous nerve of the thigh, the pudendal, sciatic, tibial, sural, medial plantar, lateral plantar, common peroneal, deep peroneal and superficial peroneal nerves. It includes diagrams showing the proper positioning of the sonographic probe, plus USG images of the successively discussed nerves and their surrounding structures. The ultrasonographic appearance of the peripheral nerves in the lower limb is identical to the nerves in the upper limb. However, when imaging the lower extremity, convex probes are more often utilized, to capture deeply-seated nerves. The examination technique, similarly to that used in visualizing the nerves of upper extremity, consists of locating the nerve at a characteristic anatomic reference point and tracking it using the "elevator technique". All 3 parts of the article series should serve as an introduction to a discussion of peripheral nerve pathologies, which will be presented in subsequent issues of the "Journal of Ultrasonography".

  20. Adjusted functional boxplots for spatio-temporal data visualization and outlier detection

    KAUST Repository

    Sun, Ying; Genton, Marc G.

    2011-01-01

    This article proposes a simulation-based method to adjust functional boxplots for correlations when visualizing functional and spatio-temporal data, as well as detecting outliers. We start by investigating the relationship between the spatio

  1. System for visualizing a body by detecting the radiation of a tracer contained therein

    International Nuclear Information System (INIS)

    Vacher, Jacques.

    1980-01-01

    This invention concerns a device for visualizing a body by detecting the radiation from a tracer composed of positron emitters contained in this body. This system has a particular application in tomography and hence for the visualization of a group of organs in a given cross-section. It includes: - detection cells positioned on both sides of the body to detect the gamma particles delivered by each positron emitter, in two opposite directions, - devices for localizing cells opposed in pairs, on both sides of the body, each opposed pair of cells being located on a straight line passing through a positron emitter, - systems for coding the localization of these pairs of opposed cells, - systems for memorizing these coded localization signals, - facilities for processing these stored signals, - visual displays controlled by the data processing units, to show the image of the body as from the various coded and memorized signals [fr

  2. a Novel Ship Detection Method for Large-Scale Optical Satellite Images Based on Visual Lbp Feature and Visual Attention Model

    Science.gov (United States)

    Haigang, Sui; Zhina, Song

    2016-06-01

    Reliably ship detection in optical satellite images has a wide application in both military and civil fields. However, this problem is very difficult in complex backgrounds, such as waves, clouds, and small islands. Aiming at these issues, this paper explores an automatic and robust model for ship detection in large-scale optical satellite images, which relies on detecting statistical signatures of ship targets, in terms of biologically-inspired visual features. This model first selects salient candidate regions across large-scale images by using a mechanism based on biologically-inspired visual features, combined with visual attention model with local binary pattern (CVLBP). Different from traditional studies, the proposed algorithm is high-speed and helpful to focus on the suspected ship areas avoiding the separation step of land and sea. Largearea images are cut into small image chips and analyzed in two complementary ways: Sparse saliency using visual attention model and detail signatures using LBP features, thus accordant with sparseness of ship distribution on images. Then these features are employed to classify each chip as containing ship targets or not, using a support vector machine (SVM). After getting the suspicious areas, there are still some false alarms such as microwaves and small ribbon clouds, thus simple shape and texture analysis are adopted to distinguish between ships and nonships in suspicious areas. Experimental results show the proposed method is insensitive to waves, clouds, illumination and ship size.

  3. Lateralized discrimination of emotional scenes in peripheral vision.

    Science.gov (United States)

    Calvo, Manuel G; Rodríguez-Chinea, Sandra; Fernández-Martín, Andrés

    2015-03-01

    This study investigates whether there is lateralized processing of emotional scenes in the visual periphery, in the absence of eye fixations; and whether this varies with emotional valence (pleasant vs. unpleasant), specific emotional scene content (babies, erotica, human attack, mutilation, etc.), and sex of the viewer. Pairs of emotional (positive or negative) and neutral photographs were presented for 150 ms peripherally (≥6.5° away from fixation). Observers judged on which side the emotional picture was located. Low-level image properties, scene visual saliency, and eye movements were controlled. Results showed that (a) correct identification of the emotional scene exceeded the chance level; (b) performance was more accurate and faster when the emotional scene appeared in the left than in the right visual field; (c) lateralization was equivalent for females and males for pleasant scenes, but was greater for females and unpleasant scenes; and (d) lateralization occurred similarly for different emotional scene categories. These findings reveal discrimination between emotional and neutral scenes, and right brain hemisphere dominance for emotional processing, which is modulated by sex of the viewer and scene valence, and suggest that coarse affective significance can be extracted in peripheral vision.

  4. Interest of Electrostimulation of Peripheral Motor Nerves during Percutaneous Thermal Ablation

    International Nuclear Information System (INIS)

    Tsoumakidou, Georgia; Garnon, Julien; Ramamurthy, Nitin; Buy, Xavier; Gangi, Afshin

    2013-01-01

    Purpose: We present our experience of utilizing peripheral nerve electrostimulation as a complementary monitoring technique during percutaneous thermal ablation procedures; and we highlight its utility and feasibility in the prevention of iatrogenic neurologic thermal injury. Methods: Peripheral motor nerve electrostimulation was performed in 12 patients undergoing percutaneous image-guided thermal ablations of spinal/pelvic lesions in close proximity to the spinal cord and nerve roots. Electrostimulation was used in addition to existing insulation (active warming/cooling with hydrodissection, passive insulation with CO 2 insufflation) and temperature monitoring (thermocouples) techniques. Impending neurologic deficit was defined as a visual reduction of muscle response or need for a stronger electric current to evoke muscle contraction, compared with baseline. Results: Significant reduction of the muscle response to electrostimulation was observed in three patients during the ablation, necessitating temporary interruption, followed by injection of warm/cool saline. This resulted in complete recovery of the muscle response in two cases, while for the third patient the response did not improve and the procedure was terminated. No patient experienced postoperative motor deficit. Conclusion: Peripheral motor nerve electrostimulation is a simple, easily accessible technique allowing early detection of impending neurologic injury during percutaneous image-guided thermal ablation. It complements existing monitoring techniques and provides a functional assessment along the whole length of the nerve

  5. Interest of Electrostimulation of Peripheral Motor Nerves during Percutaneous Thermal Ablation

    Energy Technology Data Exchange (ETDEWEB)

    Tsoumakidou, Georgia, E-mail: gtsoumakidou@yahoo.com; Garnon, Julien, E-mail: juliengarnon@gmail.com; Ramamurthy, Nitin, E-mail: nitin_ramamurthy@hotmail.com; Buy, Xavier, E-mail: xbuy@ymail.com; Gangi, Afshin, E-mail: gangi@unistra.fr [University Hospital of Strasbourg (France)

    2013-12-15

    Purpose: We present our experience of utilizing peripheral nerve electrostimulation as a complementary monitoring technique during percutaneous thermal ablation procedures; and we highlight its utility and feasibility in the prevention of iatrogenic neurologic thermal injury. Methods: Peripheral motor nerve electrostimulation was performed in 12 patients undergoing percutaneous image-guided thermal ablations of spinal/pelvic lesions in close proximity to the spinal cord and nerve roots. Electrostimulation was used in addition to existing insulation (active warming/cooling with hydrodissection, passive insulation with CO{sub 2} insufflation) and temperature monitoring (thermocouples) techniques. Impending neurologic deficit was defined as a visual reduction of muscle response or need for a stronger electric current to evoke muscle contraction, compared with baseline. Results: Significant reduction of the muscle response to electrostimulation was observed in three patients during the ablation, necessitating temporary interruption, followed by injection of warm/cool saline. This resulted in complete recovery of the muscle response in two cases, while for the third patient the response did not improve and the procedure was terminated. No patient experienced postoperative motor deficit. Conclusion: Peripheral motor nerve electrostimulation is a simple, easily accessible technique allowing early detection of impending neurologic injury during percutaneous image-guided thermal ablation. It complements existing monitoring techniques and provides a functional assessment along the whole length of the nerve.

  6. Remote Sensing of Martian Terrain Hazards via Visually Salient Feature Detection

    Science.gov (United States)

    Al-Milli, S.; Shaukat, A.; Spiteri, C.; Gao, Y.

    2014-04-01

    The main objective of the FASTER remote sensing system is the detection of rocks on planetary surfaces by employing models that can efficiently characterise rocks in terms of semantic descriptions. The proposed technique abates some of the algorithmic limitations of existing methods with no training requirements, lower computational complexity and greater robustness towards visual tracking applications over long-distance planetary terrains. Visual saliency models inspired from biological systems help to identify important regions (such as rocks) in the visual scene. Surface rocks are therefore completely described in terms of their local or global conspicuity pop-out characteristics. These local and global pop-out cues are (but not limited to); colour, depth, orientation, curvature, size, luminance intensity, shape, topology etc. The currently applied methods follow a purely bottom-up strategy of visual attention for selection of conspicuous regions in the visual scene without any topdown control. Furthermore the choice of models used (tested and evaluated) are relatively fast among the state-of-the-art and have very low computational load. Quantitative evaluation of these state-ofthe- art models was carried out using benchmark datasets including the Surrey Space Centre Lab Testbed, Pangu generated images, RAL Space SEEKER and CNES Mars Yard datasets. The analysis indicates that models based on visually salient information in the frequency domain (SRA, SDSR, PQFT) are the best performing ones for detecting rocks in an extra-terrestrial setting. In particular the SRA model seems to be the most optimum of the lot especially that it requires the least computational time while keeping errors competitively low. The salient objects extracted using these models can then be merged with the Digital Elevation Models (DEMs) generated from the same navigation cameras in order to be fused to the navigation map thus giving a clear indication of the rock locations.

  7. Role of syllable segmentation processes in peripheral word recognition.

    Science.gov (United States)

    Bernard, Jean-Baptiste; Calabrèse, Aurélie; Castet, Eric

    2014-12-01

    Previous studies of foveal visual word recognition provide evidence for a low-level syllable decomposition mechanism occurring during the recognition of a word. We investigated if such a decomposition mechanism also exists in peripheral word recognition. Single words were visually presented to subjects in the peripheral field using a 6° square gaze-contingent simulated central scotoma. In the first experiment, words were either unicolor or had their adjacent syllables segmented with two different colors (color/syllable congruent condition). Reaction times for correct word identification were measured for the two different conditions and for two different print sizes. Results show a significant decrease in reaction time for the color/syllable congruent condition compared with the unicolor condition. A second experiment suggests that this effect is specific to syllable decomposition and results from strategic, presumably involving attentional factors, rather than stimulus-driven control.

  8. F wave index: A diagnostic tool for peripheral neuropathy

    Directory of Open Access Journals (Sweden)

    G R Sathya

    2017-01-01

    Interpretation & conclusions: Our results showed that F wave index in upper limb was significantly lower in patients with peripheral neuropathy than the healthy controls, and could be used for early detection of peripheral neuropathy.

  9. Visual field tunneling in aviators induced by memory demands.

    Science.gov (United States)

    Williams, L J

    1995-04-01

    Aviators are required rapidly and accurately to process enormous amounts of visual information located foveally and peripherally. The present study, expanding upon an earlier study (Williams, 1988), required young aviators to process within the framework of a single eye fixation a briefly displayed foveally presented memory load while simultaneously trying to identify common peripheral targets presented on the same display at locations up to 4.5 degrees of visual angle from the fixation point. This task, as well as a character classification task (Williams, 1985, 1988), has been shown to be very difficult for nonaviators: It results in a tendency toward tunnel vision. Limited preliminary measurements of peripheral accuracy suggested that aviators might be less susceptible than nonaviators to this visual tunneling. The present study demonstrated moderate susceptibility to cognitively induced tunneling in aviators when the foveal task was sufficiently difficult and reaction time was the principal dependent measure.

  10. Emotion has no impact on attention in a change detection flicker task

    Directory of Open Access Journals (Sweden)

    Robert Colin Alan Bendall

    2015-10-01

    Full Text Available Past research provides conflicting findings regarding the influence of emotion on visual attention. Early studies suggested a broadening of attentional resources in relation to positive mood. However, more recent evidence indicates that positive emotions may not have a beneficial impact on attention, and that the relationship between emotion and attention may be mitigated by factors such as task demand or stimulus valence. The current study explored the effect of emotion on attention using the change detection flicker paradigm. Participants were induced into positive, neutral, and negative mood states and then completed a change detection task. A series of neutral scenes were presented and participants had to identify the location of a disappearing item in each scene. The change was made to the centre or the periphery of each scene and it was predicted that peripheral changes would be detected quicker in the positive mood condition and slower in the negative mood condition, compared to the neutral condition. In contrast to previous findings emotion had no influence on attention and whilst central changes were detected faster than peripheral changes, change blindness was not affected by mood. The findings suggest that the relationship between emotion and visual attention is influenced by the characteristics of a task, and any beneficial impact of positive emotion may be related to processing style rather than a broadening of attentional resources.

  11. Audio/visual analysis for high-speed TV advertisement detection from MPEG bitstream

    OpenAIRE

    Sadlier, David A.

    2002-01-01

    Advertisement breaks dunng or between television programmes are typically flagged by senes of black-and-silent video frames, which recurrendy occur in order to audio-visually separate individual advertisement spots from one another. It is the regular prevalence of these flags that enables automatic differentiauon between what is programme content and what is advertisement break. Detection of these audio-visual depressions within broadcast television content provides a basis on which advertise...

  12. The development of a visual system for the detection of obstructions for visually impaired people

    International Nuclear Information System (INIS)

    Okayasu, Mitsuhiro

    2009-01-01

    In this paper, the author presents a new visual system that can aid visually impaired people in walking. The system provides object information (that is, shape and location) through the sense of touch. This visual system depends on three different components: (i) an infrared camera sensor that detects the obstruction, (ii) a control system that measures the distance between the obstruction and the sensor, and (iii) a tooling apparatus with small pins (φ1 mm) used in forming a three-dimensional shape of the obstruction. The pins, arranged on a 6x6 matrix, move longitudinally between the retracted and extended positions based on the distance data. The pin extends individually, while the pin tip reflects the object's outer surface. The length of the pin from the base surface is proportional to the distance of the sensor from the obstruction. An ultrasonic actuator, controlled at a 15Hz frame rate, is the driving force for the pin movement. The tactile image of the 3D shape can provide information about the obstruction

  13. Fat Content Modulates Rapid Detection of Food: A Visual Search Study Using Fast Food and Japanese Diet

    OpenAIRE

    Sawada, Reiko; Sato, Wataru; Toichi, Motomi; Fushiki, Tohru

    2017-01-01

    Rapid detection of food is crucial for the survival of organisms. However, previous visual search studies have reported discrepant results regarding the detection speeds for food vs. non-food items; some experiments showed faster detection of food than non-food, whereas others reported null findings concerning any speed advantage for the detection of food vs. non-food. Moreover, although some previous studies showed that fat content can affect visual attention for food, the effect of fat cont...

  14. Normal and sonographic anatomy of selected peripheral nerves. Part III: Peripheral nerves of the lower limb

    Directory of Open Access Journals (Sweden)

    Berta Kowalska

    2012-06-01

    Full Text Available The ultrasonographic examination is currently increasingly used in imaging peripheral nerves, serving to supplement the physical examination, electromyography and magnetic resonance imaging. As in the case of other USG imaging studies, the examination of peripheral nerves is non-invasive and well-tolerated by patients. The typical ultrasonographic picture of peripheral nerves as well as the examination technique have been discussed in part I of this article series, following the example of the median nerve. Part II of the series presented the normal anatomy and the technique for examining the peripheral nerves of the upper limb. This part of the article series focuses on the anatomy and technique for examining twelve normal peripheral nerves of the lower extremity: the iliohypogastric and ilioinguinal nerves, the lateral cutaneous nerve of the thigh, the pudendal, sciatic, tibial, sural, medial plantar, lateral plantar, common peroneal, deep peroneal and superficial peroneal nerves. It includes diagrams showing the proper positioning of the sonographic probe, plus USG images of the successively discussed nerves and their surrounding structures. The ultrasonographic appearance of the peripheral nerves in the lower limb is identical to the nerves in the upper limb. However, when imaging the lower extremity, convex probes are more often utilized, to capture deeply-seated nerves. The examination technique, similarly to that used in visualizing the nerves of upper extremity, consists of locating the nerve at a characteristic anatomic reference point and tracking it using the “elevator technique”. All 3 parts of the article series should serve as an introduction to a discussion of peripheral nerve pathologies, which will be presented in subsequent issues of the “Journal of Ultrasonography”.

  15. Sustained change blindness to incremental scene rotation: a dissociation between explicit change detection and visual memory.

    Science.gov (United States)

    Hollingworth, Andrew; Henderson, John M

    2004-07-01

    In a change detection paradigm, the global orientation of a natural scene was incrementally changed in 1 degree intervals. In Experiments 1 and 2, participants demonstrated sustained change blindness to incremental rotation, often coming to consider a significantly different scene viewpoint as an unchanged continuation of the original view. Experiment 3 showed that participants who failed to detect the incremental rotation nevertheless reliably detected a single-step rotation back to the initial view. Together, these results demonstrate an important dissociation between explicit change detection and visual memory. Following a change, visual memory is updated to reflect the changed state of the environment, even if the change was not detected.

  16. Association and comparison between visual inspection and bitewing radiography for the detection of recurrent dental caries under restorations.

    Science.gov (United States)

    Lino, José R; Ramos-Jorge, Joana; Coelho, Valéria Silveira; Ramos-Jorge, Maria L; Moysés, Marcos R; Ribeiro, José C R

    2015-08-01

    The aim of the present study was to investigate, in posterior teeth, the association between the characteristics of the margins of a restoration visually inspected and the presence, under restorations, of recurrent or residual dental caries detected by radiographic examination. Furthermore, the agreement between visual inspection and radiographs to detect dental caries was assessed. Eighty-five permanent molars and premolars with resin restorations on the interproximal and/or occlusal faces, from 18 patients, were submitted for visual inspection and radiographic examination. The visual inspection involved the criteria of the International Caries Detection and Assessment System (ICDAS). Bitewing radiographs were used for the radiographic examination. Logistic regression was used to analyse the association between the characteristics of the margins of a restoration assessed by visual inspection (absence of dental caries, or early, established, inactive and active lesions) and the presence of recurrent caries detected by radiographs. Kappa coefficients were calculated for determining agreement between the two methods. The Kappa coefficient for agreement between visual inspection and radiographic examination was 0.19. Established lesions [odds ratio (OR) = 9.89; 95% confidence interval (95% CI): 2.94-33.25; P caries detected by radiographs. Restorations with established and active lesions at the margins had a greater chance of exhibiting recurrent or residual lesions in the radiographic examination. The present findings demonstrate that restorations with established and active lesions at the margins when visually inspected often require removal and retreatment. © 2015 FDI World Dental Federation.

  17. Visual detection of multiple genetically modified organisms in a capillary array.

    Science.gov (United States)

    Shao, Ning; Chen, Jianwei; Hu, Jiaying; Li, Rong; Zhang, Dabing; Guo, Shujuan; Hui, Junhou; Liu, Peng; Yang, Litao; Tao, Sheng-Ce

    2017-01-31

    There is an urgent need for rapid, low-cost multiplex methodologies for the monitoring of genetically modified organisms (GMOs). Here, we report a C[combining low line]apillary A[combining low line]rray-based L[combining low line]oop-mediated isothermal amplification for M[combining low line]ultiplex visual detection of nucleic acids (CALM) platform for the simple and rapid monitoring of GMOs. In CALM, loop-mediated isothermal amplification (LAMP) primer sets are pre-fixed to the inner surface of capillaries. The surface of the capillary array is hydrophobic while the capillaries are hydrophilic, enabling the simultaneous loading and separation of the LAMP reaction mixtures into each capillary by capillary forces. LAMP reactions in the capillaries are then performed in parallel, and the results are visually detected by illumination with a hand-held UV device. Using CALM, we successfully detected seven frequently used transgenic genes/elements and five plant endogenous reference genes with high specificity and sensitivity. Moreover, we found that measurements of real-world blind samples by CALM are consistent with results obtained by independent real-time PCRs. Thus, with an ability to detect multiple nucleic acids in a single easy-to-operate test, we believe that CALM will become a widely applied technology in GMO monitoring.

  18. Visual Method for Detecting Contaminant on Dried Nutmeg Using Fluorescence Imaging

    Science.gov (United States)

    Dahlan, S. A.; Ahmad, U.; Subrata, I. D. M.

    2018-05-01

    Traditional practice of nutmeg sun-drying causes some fungi such as Aspergillus flavus to grow. One of the secondary metabolites of A. flavus named aflatoxin (AFs) is known to be carcinogenic, so the dried nutmeg kernel must be aflatoxin-free in the trading. Aflatoxin detection requires time and costly, make it difficult to conduct at the farmers level. This study aims to develop a simple and low-cost method to detect aflatoxin at the farmer level. Fresh nutmeg seeds were dried in two ways; sundried everyday (continuous), and sundried every two days (intermittent), both for around 18 days. The dried nutmeg seeds are then stored in a rice sack under normal conditions until the fungi grow, then they were opened and the images of kernels were captured using a CCD camera, with normal light and UV light sources. Visual observation on images captured in normal light source was able to detect the presence of fungi on dried kernels, by 28.0% for continuous and 26.2% for intermittent sun-drying. Visual observation on images captured in UV light source was able to detect the presence of aflatoxin on dried kernels, indicated by blue luminance on kernel, by 10.4% and 13.4% for continuous and intermittent sun-drying.

  19. Ex vivo measurement of calpain activation in human peripheral blood lymphocytes by detection of immunoreactive products of calpastatin degradation.

    Directory of Open Access Journals (Sweden)

    Jacek M Witkowski

    2008-01-01

    Full Text Available Limited proteolysis of multiple intracellular proteins by endogenous Ca-dependent cysteine proteases--calpains--is an important regulatory mechanism for cell proliferation, apoptosis etc. Its importance for cellular functions is stressed by existence of endogenous calpain inhibitors--calpastatins. The calpain-calpastatin system within living cells is in a fragile balance, which depends on both partners. The interdependence of calpain--a protease--and calpastatin--an endogenous inhibitor and at the same time a substrate for this enzyme makes any assessment of actual activity of this enzyme in the cells very difficult. In this work we made an attempt to estimate and compare the activity of calpain in human peripheral blood lymphocytes by assessing the levels of limited proteolysis of calpastatin in these cells by western blot, while at the same time the levels of calpain protein inside these cells was measured by flow cytometry. Our results indicate that it is possible to compare (semi-quantitatively the activities of calpain in peripheral blood CD4+ and CD19+ lymphocytes from various donors that way. Preliminary results showed that calpain activity is increased in the CD4+ T cells isolated from peripheral blood of rheumatoid arthritis patients as compared to control lymphocytes. Extremely high intrinsic activity of calpain was detected in chronic lymphocytic leukemia (CD19+ cells. All this confirms the detection of immunoreactive products of calpastatin as a good maker of endogenous calpain activity.

  20. Systematic identification and validation of candidate genes for detection of circulating tumor cells in peripheral blood specimens of colorectal cancer patients.

    Science.gov (United States)

    Findeisen, Peter; Röckel, Matthias; Nees, Matthias; Röder, Christian; Kienle, Peter; Von Knebel Doeberitz, Magnus; Kalthoff, Holger; Neumaier, Michael

    2008-11-01

    The presence of tumor cells in peripheral blood is being regarded increasingly as a clinically relevant prognostic factor for colorectal cancer patients. Current molecular methods are very sensitive but due to low specificity their diagnostic value is limited. This study was undertaken in order to systematically identify and validate new colorectal cancer (CRC) marker genes for improved detection of minimal residual disease in peripheral blood mononuclear cells of colorectal cancer patients. Marker genes with upregulated gene expression in colorectal cancer tissue and cell lines were identified using microarray experiments and publicly available gene expression data. A systematic iterative approach was used to reduce a set of 346 candidate genes, reportedly associated with CRC to a selection of candidate genes that were then further validated by relative quantitative real-time RT-PCR. Analytical sensitivity of RT-PCR assays was determined by spiking experiments with CRC cells. Diagnostic sensitivity as well as specificity was tested on a control group consisting of 18 CRC patients compared to 12 individuals without malignant disease. From a total of 346-screened genes only serine (or cysteine) proteinase inhibitor, clade B (ovalbumin), member 5 (SERPINB5) showed significantly elevated transcript levels in peripheral venous blood specimens of tumor patients when compared to the nonmalignant control group. These results were confirmed by analysis of an enlarged collective consisting of 63 CRC patients and 36 control individuals without malignant disease. In conclusion SERPINB5 seems to be a promising marker for detection of circulating tumor cells in peripheral blood of colorectal cancer patients.

  1. The peripheral blood volume influenced by various external factors

    International Nuclear Information System (INIS)

    Ittner, A.; Scheibe, J.; Stoll, W.

    1982-01-01

    The dependence of the peripheral blood volume upon various exogenous factors was studied in male sports students using /sup 113m/InCl. The results obtained revealed that whole-body exertions and local muscular activity produce an increase of the blood volume in the lower extremities associated with increased blood circulation. The passive measures applied caused also an increase of the blood volume, but not in all of the subjects examined. Isometric concentrations led to a highly significant reduction of the peripheral blood volume. The scintigraphic method for the visualization of the blood volume in peripheral regions of the body can be regarded as suitable for the study of hemodynamics and for the substantiation of the efficiency of measures promoting restoration. (author)

  2. PERIPHERAL RETINAL FINDINGS IN HIGHLY MYOPIC CHILDREN ≤10 YEARS OF AGE

    Science.gov (United States)

    Bansal, Alok S.; Hubbard, G. Baker

    2011-01-01

    Purpose The purpose of this study was to characterize the peripheral retinal findings in highly myopic young children without other known risk factors for retinal detachment. Methods A retrospective review of all cases of children ≤10 years of age with high myopia (>6.00 diopters) who were evaluated for presumed risk of retinal detachment by either an examination under anesthesia or office examination by a single retina specialist from January 2001 through December 2008. Patients with regressed retinopathy of pre-maturity, retinal detachment in the fellow eye, or known Stickler syndrome were excluded. Results Fifty-four eyes of 30 patients with high myopia were examined. Twenty-six eyes of 14 patients were examined under anesthesia because of the examiner’s inability to adequately visualize the peripheral retina during an office examination. Mean age at examination was 6 ± 3 (range, 1–10) years. Mean spherical equivalent refractive error was −13.88 ± 3.79 (range, −6.00 to −25.00) diopters. Peripheral retinal findings were identified in 33% of eyes, the most common being lattice degeneration (20%), white without pressure (11%), and retinal holes with subretinal fluid (4%). Conclusion Approximately one third of highly myopic children in our study showed peripheral retinal findings. If the peripheral retina is not adequately visualized during an office evaluation, examination under anesthesia should be considered. PMID:20224463

  3. Synchrony dynamics in monkey V1 predict success in visual detection

    NARCIS (Netherlands)

    van der Togt, C.; Kalitzin, S.; Spekreijse, H.; Lamme, V.A.F.; Supèr, H.

    2006-01-01

    Behavioral measures such as expectancy and attention have been associated with the strength of synchronous neural activity. On this basis, it is hypothesized that synchronous activity affects our ability to detect and recognize visual objects. To investigate the role of synchronous activity in

  4. Management of peripheral facial nerve palsy

    OpenAIRE

    Finsterer, Josef

    2008-01-01

    Peripheral facial nerve palsy (FNP) may (secondary FNP) or may not have a detectable cause (Bell?s palsy). Three quarters of peripheral FNP are primary and one quarter secondary. The most prevalent causes of secondary FNP are systemic viral infections, trauma, surgery, diabetes, local infections, tumor, immunological disorders, or drugs. The diagnosis of FNP relies upon the presence of typical symptoms and signs, blood chemical investigations, cerebro-spinal-fluid-investigations, X-ray of the...

  5. Alerts Analysis and Visualization in Network-based Intrusion Detection Systems

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Dr. Li [University of Tennessee

    2010-08-01

    The alerts produced by network-based intrusion detection systems, e.g. Snort, can be difficult for network administrators to efficiently review and respond to due to the enormous number of alerts generated in a short time frame. This work describes how the visualization of raw IDS alert data assists network administrators in understanding the current state of a network and quickens the process of reviewing and responding to intrusion attempts. The project presented in this work consists of three primary components. The first component provides a visual mapping of the network topology that allows the end-user to easily browse clustered alerts. The second component is based on the flocking behavior of birds such that birds tend to follow other birds with similar behaviors. This component allows the end-user to see the clustering process and provides an efficient means for reviewing alert data. The third component discovers and visualizes patterns of multistage attacks by profiling the attacker s behaviors.

  6. Direct visualization of antigen-specific T cells: HTLV-1 Tax11-19- specific CD8(+) T cells are activated in peripheral blood and accumulate in cerebrospinal fluid from HAM/TSP patients.

    Science.gov (United States)

    Greten, T F; Slansky, J E; Kubota, R; Soldan, S S; Jaffee, E M; Leist, T P; Pardoll, D M; Jacobson, S; Schneck, J P

    1998-06-23

    Human T lymphotropic virus type 1 (HTLV-1) -associated myelopathy/tropic spastic paraparesis is a demyelinating inflammatory neurologic disease associated with HTLV-1 infection. HTLV-1 Tax11-19-specific cytotoxic T cells have been isolated from HLA-A2-positive patients. We have used a peptide-loaded soluble HLA-A2-Ig complex to directly visualize HTLV-1 Tax11-19-specific T cells from peripheral blood and cerebrospinal fluid without in vitro stimulation. Five of six HTLV-1-associated myelopathy/tropic spastic paraparesis patients carried a significant number (up to 13.87%) of CD8(+) lymphocytes specific for the HTLV-1 Tax11-19 peptide in their peripheral blood, which were not found in healthy controls. Simultaneous comparison of peripheral blood and cerebrospinal fluid from one patient revealed 2.5-fold more Tax11-19-specific T cells in the cerebrospinal fluid (23.7% vs. 9.4% in peripheral blood lymphocyte). Tax11-19-specific T cells were seen consistently over a 9-yr time course in one patient as far as 19 yrs after the onset of clinical symptoms. Further analysis of HTLV-1 Tax11-19-specific CD8(+) T lymphocytes in HAM/TSP patients showed different expression patterns of activation markers, intracellular TNF-alpha and gamma-interferon depending on the severity of the disease. Thus, visualization of antigen-specific T cells demonstrates that HTLV-1 Tax11-19-specific CD8(+) T cells are activated, persist during the chronic phase of the disease, and accumulate in cerebrospinal fluid, showing their pivotal role in the pathogenesis of this neurologic disease.

  7. Competitive interactions of attentional resources in early visual cortex during sustained visuospatial attention within or between visual hemifields: evidence for the different-hemifield advantage.

    Science.gov (United States)

    Walter, Sabrina; Quigley, Cliodhna; Mueller, Matthias M

    2014-05-01

    Performing a task across the left and right visual hemifields results in better performance than in a within-hemifield version of the task, termed the different-hemifield advantage. Although recent studies used transient stimuli that were presented with long ISIs, here we used a continuous objective electrophysiological (EEG) measure of competitive interactions for attentional processing resources in early visual cortex, the steady-state visual evoked potential (SSVEP). We frequency-tagged locations in each visual quadrant and at central fixation by flickering light-emitting diodes (LEDs) at different frequencies to elicit distinguishable SSVEPs. Stimuli were presented for several seconds, and participants were cued to attend to two LEDs either in one (Within) or distributed across left and right visual hemifields (Across). In addition, we introduced two reference measures: one for suppressive interactions between the peripheral LEDs by using a task at fixation where attention was withdrawn from the periphery and another estimating the upper bound of SSVEP amplitude by cueing participants to attend to only one of the peripheral LEDs. We found significantly greater SSVEP amplitude modulations in Across compared with Within hemifield conditions. No differences were found between SSVEP amplitudes elicited by the peripheral LEDs when participants attended to the centrally located LEDs compared with when peripheral LEDs had to be ignored in Across and Within trials. Attending to only one LED elicited the same SSVEP amplitude as Across conditions. Although behavioral data displayed a more complex pattern, SSVEP amplitudes were well in line with the predictions of the different-hemifield advantage account during sustained visuospatial attention.

  8. Activation of lateral geniculate nucleus and primary visual cortex as detected by functional magnetic resonance imaging in normal subjects and in patients with visual disturbance

    Energy Technology Data Exchange (ETDEWEB)

    Miki, Atsushi [Niigata Univ. (Japan). Graduate School of Medical and Dental Sciences

    2002-12-01

    Functional magnetic resonance imaging (fMRI) during visual stimulation can detect regional cerebral blood flow changes that reflect neural activity in the lateral geniculate nucleus and primary visual cortex, which are major relay points in the human afferent visual system. FMRI has been used in the clinical evaluation of visual disorders such as homonymous hemianopia and unilateral eye diseases (optic neuritis, amblyopia, and so on). Future development in the data acquisition and data analysis may facilitate the use of fMRI for the management of patients with visual deficits and understanding of the visual disorders. (author)

  9. Activation of lateral geniculate nucleus and primary visual cortex as detected by functional magnetic resonance imaging in normal subjects and in patients with visual disturbance

    International Nuclear Information System (INIS)

    Miki, Atsushi

    2002-01-01

    Functional magnetic resonance imaging (fMRI) during visual stimulation can detect regional cerebral blood flow changes that reflect neural activity in the lateral geniculate nucleus and primary visual cortex, which are major relay points in the human afferent visual system. FMRI has been used in the clinical evaluation of visual disorders such as homonymous hemianopia and unilateral eye diseases (optic neuritis, amblyopia, and so on). Future development in the data acquisition and data analysis may facilitate the use of fMRI for the management of patients with visual deficits and understanding of the visual disorders. (author)

  10. Fat Content Modulates Rapid Detection of Food: A Visual Search Study Using Fast Food and Japanese Diet

    Directory of Open Access Journals (Sweden)

    Reiko Sawada

    2017-06-01

    Full Text Available Rapid detection of food is crucial for the survival of organisms. However, previous visual search studies have reported discrepant results regarding the detection speeds for food vs. non-food items; some experiments showed faster detection of food than non-food, whereas others reported null findings concerning any speed advantage for the detection of food vs. non-food. Moreover, although some previous studies showed that fat content can affect visual attention for food, the effect of fat content on the detection of food remains unclear. To investigate these issues, we measured reaction times (RTs during a visual search task in which participants with normal weight detected high-fat food (i.e., fast food, low-fat food (i.e., Japanese diet, and non-food (i.e., kitchen utensils targets within crowds of non-food distractors (i.e., cars. Results showed that RTs for food targets were shorter than those for non-food targets. Moreover, the RTs for high-fat food were shorter than those for low-fat food. These results suggest that food is more rapidly detected than non-food within the environment and that a higher fat content in food facilitates rapid detection.

  11. Fat Content Modulates Rapid Detection of Food: A Visual Search Study Using Fast Food and Japanese Diet.

    Science.gov (United States)

    Sawada, Reiko; Sato, Wataru; Toichi, Motomi; Fushiki, Tohru

    2017-01-01

    Rapid detection of food is crucial for the survival of organisms. However, previous visual search studies have reported discrepant results regarding the detection speeds for food vs. non-food items; some experiments showed faster detection of food than non-food, whereas others reported null findings concerning any speed advantage for the detection of food vs. non-food. Moreover, although some previous studies showed that fat content can affect visual attention for food, the effect of fat content on the detection of food remains unclear. To investigate these issues, we measured reaction times (RTs) during a visual search task in which participants with normal weight detected high-fat food (i.e., fast food), low-fat food (i.e., Japanese diet), and non-food (i.e., kitchen utensils) targets within crowds of non-food distractors (i.e., cars). Results showed that RTs for food targets were shorter than those for non-food targets. Moreover, the RTs for high-fat food were shorter than those for low-fat food. These results suggest that food is more rapidly detected than non-food within the environment and that a higher fat content in food facilitates rapid detection.

  12. Fat Content Modulates Rapid Detection of Food: A Visual Search Study Using Fast Food and Japanese Diet

    Science.gov (United States)

    Sawada, Reiko; Sato, Wataru; Toichi, Motomi; Fushiki, Tohru

    2017-01-01

    Rapid detection of food is crucial for the survival of organisms. However, previous visual search studies have reported discrepant results regarding the detection speeds for food vs. non-food items; some experiments showed faster detection of food than non-food, whereas others reported null findings concerning any speed advantage for the detection of food vs. non-food. Moreover, although some previous studies showed that fat content can affect visual attention for food, the effect of fat content on the detection of food remains unclear. To investigate these issues, we measured reaction times (RTs) during a visual search task in which participants with normal weight detected high-fat food (i.e., fast food), low-fat food (i.e., Japanese diet), and non-food (i.e., kitchen utensils) targets within crowds of non-food distractors (i.e., cars). Results showed that RTs for food targets were shorter than those for non-food targets. Moreover, the RTs for high-fat food were shorter than those for low-fat food. These results suggest that food is more rapidly detected than non-food within the environment and that a higher fat content in food facilitates rapid detection. PMID:28690568

  13. IAG ring test visual detection of ergot sclerotia in rye 2015

    NARCIS (Netherlands)

    Raamsdonk, van L.W.D.; Rhee, van de N.; Vliege, J.J.M.; Pinckaers, V.G.Z.

    2016-01-01

    Ergot alkaloids are recognised as seriously toxic compounds, which caused a series of outbreaks in the past. In the EU, enforcement is implemented by visual detection and quantification of ergot sclerotia produced by moulds of the genus Claviceps. On behalf of the IAG section Feedstuff Microscopy,

  14. Spatially valid proprioceptive cues improve the detection of a visual stimulus

    DEFF Research Database (Denmark)

    Jackson, Carl P T; Miall, R Chris; Balslev, Daniela

    2010-01-01

    , which has been demonstrated for other modality pairings. The aim of this study was to test whether proprioceptive signals can spatially cue a visual target to improve its detection. Participants were instructed to use a planar manipulandum in a forward reaching action and determine during this movement...

  15. Imaging of the peripheral retina

    Directory of Open Access Journals (Sweden)

    Marcus Kernt

    2013-01-01

    Full Text Available The technical progress of the recent years has revolutionized imaging in ophthalmology. Scanning laser ophthalmoscopy (SLO, digital angiography, optical coherence tomography (OCT, and detection of fundus autofluorescence (FAF have fundamentally changed our understanding of numerous retinal and choroidal diseases. Besides the tremendous advances in macular diagnostics, there is more and more evidence that central pathologies are often directly linked to changes in the peripheral retina. This review provides a brief overview on current posterior segment imaging techniques with a special focus on the peripheral retina.

  16. Peripheral epithelial odontogenic tumor

    International Nuclear Information System (INIS)

    Carzoglio, J.; Tancredi, N.; Capurro, S.; Ravecca, T.; Scarrone, P.

    2006-01-01

    A new case of peripheral epithelial odontogenic tumor (Pindborg tumor) is reported. It is localized in the superior right gingival region, a less frequent site, and has the histopathological features previously reported. Immunochemical studies were performed, revealing a differential positive stain to cytokeratins in tumor cells deeply seated in the tumor mass, probably related to tumoral cell heterogeneity.Interestingly, in this particular case S-100 protein positive reactivity was also detected in arborescent cells intermingled with tumoral cells, resembling Langerhans cells. Even though referred in the literature in central Pindborg tumors, no references were found about their presence in peripheral tumors, like the one that is presented here

  17. detecting multiple sclerosis lesions with a fully bioinspired visual attention model

    Science.gov (United States)

    Villalon-Reina, Julio; Gutierrez-Carvajal, Ricardo; Thompson, Paul M.; Romero-Castro, Eduardo

    2013-11-01

    The detection, segmentation and quantification of multiple sclerosis (MS) lesions on magnetic resonance images (MRI) has been a very active field for the last two decades because of the urge to correlate these measures with the effectiveness of pharmacological treatment. A myriad of methods has been developed and most of these are non specific for the type of lesions and segment the lesions in their acute and chronic phases together. On the other hand, radiologists are able to distinguish between several stages of the disease on different types of MRI images. The main motivation of the work presented here is to computationally emulate the visual perception of the radiologist by using modeling principles of the neuronal centers along the visual system. By using this approach we are able to detect the lesions in the majority of the images in our population sample. This type of approach also allows us to study and improve the analysis of brain networks by introducing a priori information.

  18. Visual advantage in deaf adults linked to retinal changes.

    Directory of Open Access Journals (Sweden)

    Charlotte Codina

    Full Text Available The altered sensory experience of profound early onset deafness provokes sometimes large scale neural reorganisations. In particular, auditory-visual cross-modal plasticity occurs, wherein redundant auditory cortex becomes recruited to vision. However, the effect of human deafness on neural structures involved in visual processing prior to the visual cortex has never been investigated, either in humans or animals. We investigated neural changes at the retina and optic nerve head in profoundly deaf (N = 14 and hearing (N = 15 adults using Optical Coherence Tomography (OCT, an in-vivo light interference method of quantifying retinal micro-structure. We compared retinal changes with behavioural results from the same deaf and hearing adults, measuring sensitivity in the peripheral visual field using Goldmann perimetry. Deaf adults had significantly larger neural rim areas, within the optic nerve head in comparison to hearing controls suggesting greater retinal ganglion cell number. Deaf adults also demonstrated significantly larger visual field areas (indicating greater peripheral sensitivity than controls. Furthermore, neural rim area was significantly correlated with visual field area in both deaf and hearing adults. Deaf adults also showed a significantly different pattern of retinal nerve fibre layer (RNFL distribution compared to controls. Significant correlations between the depth of the RNFL at the inferior-nasal peripapillary retina and the corresponding far temporal and superior temporal visual field areas (sensitivity were found. Our results show that cross-modal plasticity after early onset deafness may not be limited to the sensory cortices, noting specific retinal adaptations in early onset deaf adults which are significantly correlated with peripheral vision sensitivity.

  19. Structural reorganization of the early visual cortex following Braille training in sighted adults.

    Science.gov (United States)

    Bola, Łukasz; Siuda-Krzywicka, Katarzyna; Paplińska, Małgorzata; Sumera, Ewa; Zimmermann, Maria; Jednoróg, Katarzyna; Marchewka, Artur; Szwed, Marcin

    2017-12-12

    Training can induce cross-modal plasticity in the human cortex. A well-known example of this phenomenon is the recruitment of visual areas for tactile and auditory processing. It remains unclear to what extent such plasticity is associated with changes in anatomy. Here we enrolled 29 sighted adults into a nine-month tactile Braille-reading training, and used voxel-based morphometry and diffusion tensor imaging to describe the resulting anatomical changes. In addition, we collected resting-state fMRI data to relate these changes to functional connectivity between visual and somatosensory-motor cortices. Following Braille-training, we observed substantial grey and white matter reorganization in the anterior part of early visual cortex (peripheral visual field). Moreover, relative to its posterior, foveal part, the peripheral representation of early visual cortex had stronger functional connections to somatosensory and motor cortices even before the onset of training. Previous studies show that the early visual cortex can be functionally recruited for tactile discrimination, including recognition of Braille characters. Our results demonstrate that reorganization in this region induced by tactile training can also be anatomical. This change most likely reflects a strengthening of existing connectivity between the peripheral visual cortex and somatosensory cortices, which suggests a putative mechanism for cross-modal recruitment of visual areas.

  20. Peripheral iridotomy for pigmentary glaucoma

    Science.gov (United States)

    Michelessi, Manuele; Lindsley, Kristina

    2016-01-01

    Background Glaucoma is a chronic optic neuropathy characterized by retinal ganglion cell death resulting in damage to the optic nerve head and the retinal nerve fiber layer. Pigment dispersion syndrome is characterized by a structural disturbance in the iris pigment epithelium (the densely pigmented posterior surface of the iris) that leads to dispersion of the pigment and its deposition on various structures within the eye. Pigmentary glaucoma is a specific form of open-angle glaucoma found in patients with pigment dispersion syndrome. Topcial medical therapy is usually the first-line treatment; however, peripheral laser iridotomy has been proposed as an alternate treatment. Peripheral laser iridotomy involves creating an opening in the iris tissue to allow drainage of fluid from the posterior chamber to the anterior chamber and vice versa. Equalizing the pressure within the eye may help to alleviate the friction that leads to pigment dispersion and prevent visual field deterioration. However, the effectiveness of peripheral laser iridotomy in reducing the development or progression of pigmentary glaucoma is unknown. Objectives The objective of this review was to assess the effects of peripheral laser iridotomy compared with other interventions, including medication, trabeculoplasty, and trabeculectomy, or no treatment, for pigment dispersion syndrome and pigmentary glaucoma. Search methods We searched a number of electronic databases including CENTRAL, MEDLINE and EMBASE and clinical trials websites such as (mRCT) and ClinicalTrials.gov. We last searched the electronic databases on 2 November 2015. Selection criteria We included randomized controlled trials (RCTs) that had compared peripheral laser iridotomy versus no treatment or other treatments for pigment dispersion syndrome and pigmentary glaucoma. Data collection and analysis We used standard methodological procedures for systematic reviews. Two review authors independently screened articles for eligibility

  1. Visual acuity measures do not reliably detect childhood refractive error--an epidemiological study.

    Directory of Open Access Journals (Sweden)

    Lisa O'Donoghue

    Full Text Available PURPOSE: To investigate the utility of uncorrected visual acuity measures in screening for refractive error in white school children aged 6-7-years and 12-13-years. METHODS: The Northern Ireland Childhood Errors of Refraction (NICER study used a stratified random cluster design to recruit children from schools in Northern Ireland. Detailed eye examinations included assessment of logMAR visual acuity and cycloplegic autorefraction. Spherical equivalent refractive data from the right eye were used to classify significant refractive error as myopia of at least 1DS, hyperopia as greater than +3.50DS and astigmatism as greater than 1.50DC, whether it occurred in isolation or in association with myopia or hyperopia. RESULTS: Results are presented from 661 white 12-13-year-old and 392 white 6-7-year-old school-children. Using a cut-off of uncorrected visual acuity poorer than 0.20 logMAR to detect significant refractive error gave a sensitivity of 50% and specificity of 92% in 6-7-year-olds and 73% and 93% respectively in 12-13-year-olds. In 12-13-year-old children a cut-off of poorer than 0.20 logMAR had a sensitivity of 92% and a specificity of 91% in detecting myopia and a sensitivity of 41% and a specificity of 84% in detecting hyperopia. CONCLUSIONS: Vision screening using logMAR acuity can reliably detect myopia, but not hyperopia or astigmatism in school-age children. Providers of vision screening programs should be cognisant that where detection of uncorrected hyperopic and/or astigmatic refractive error is an aspiration, current UK protocols will not effectively deliver.

  2. Integration of bio-inspired, control-based visual and olfactory data for the detection of an elusive target

    Science.gov (United States)

    Duong, Tuan A.; Duong, Nghi; Le, Duong

    2017-01-01

    In this paper, we present an integration technique using a bio-inspired, control-based visual and olfactory receptor system to search for elusive targets in practical environments where the targets cannot be seen obviously by either sensory data. Bio-inspired Visual System is based on a modeling of extended visual pathway which consists of saccadic eye movements and visual pathway (vertebrate retina, lateral geniculate nucleus and visual cortex) to enable powerful target detections of noisy, partial, incomplete visual data. Olfactory receptor algorithm, namely spatial invariant independent component analysis, that was developed based on data of old factory receptor-electronic nose (enose) of Caltech, is adopted to enable the odorant target detection in an unknown environment. The integration of two systems is a vital approach and sets up a cornerstone for effective and low-cost of miniaturized UAVs or fly robots for future DOD and NASA missions, as well as for security systems in Internet of Things environments.

  3. SYBR green-based detection of Leishmania infantum DNA using peripheral blood samples.

    Science.gov (United States)

    Ghasemian, Mehrdad; Gharavi, Mohammad Javad; Akhlaghi, Lame; Mohebali, Mehdi; Meamar, Ahmad Reza; Aryan, Ehsan; Oormazdi, Hormozd; Ghayour, Zahra

    2016-03-01

    Parasitological methods for the diagnosis of visceral leishmaniasis (VL) require invasive sampling procedures. The aim of this study was to detect Leishmania infantum (L. infantum) DNA by real time-PCR method in peripheral blood of symptomatic VL patient and compared its performance with nested PCR, an established molecular method with very high diagnostic indices. 47 parasitologically confirmed VL patients diagnosed by direct agglutination test (DAT > 3200), bone marrow aspiration and presented characteristic clinical features (fever, hepatosplenomegaly, and anemia) and 40 controls (non-endemic healthy control-30, Malaria-2, Toxoplasma gondii-2, Mycobacterium tuberculosis-2, HBV-1, HCV-1, HSV-1 and CMV-1) were enrolled in this study. SYBR-green based real time-PCR and nested PCR was performed to amplify the Kinetoplast DNA minicircle gene using the DNA extracted from Buffy coat. From among 47 patients, 45 (95.7 %) were positive by both nested-PCR and real time-PCR. These results indicate that real time-PCR was not only as sensitive as a nested-PCR assay for detection of Leishmania kDNA in clinical sample, but also more rapid. The advantage of real time-PCR based methods over nested-PCR is simple to perform, more faster in which nested-PCR requires post-PCR processing and reducing contamination risk.

  4. Training improves reading speed in peripheral vision: Is it due to attention?

    OpenAIRE

    Lee, Hye-Won; Kwon, MiYoung; Legge, Gordon E.; Gefroh, Joshua J.

    2010-01-01

    Previous research has shown that perceptual training in peripheral vision, using a letter-recognition task, increases reading speed and letter recognition (Chung, Legge, & Cheung, 2004). We tested the hypothesis that enhanced deployment of spatial attention to peripheral vision explains this training effect. Subjects were pre- and post-tested with 3 tasks at 10° above and below fixation—RSVP reading speed, trigram letter recognition (used to construct visual-span profiles), and deployment of ...

  5. Visual detection of 2,4,6-trinitrotolune by molecularly imprinted colloidal array photonic crystal

    International Nuclear Information System (INIS)

    Lu, Wei; Asher, Sanford A.; Meng, Zihui; Yan, Zequn; Xue, Min; Qiu, Lili; Yi, Da

    2016-01-01

    Graphical abstract: Molecularly imprinted colloidal array (MICA) was explored for the selective visual detection of TNT with color changing from green to red. And molecularly imprinted colloidal particles (MICs) were evaluated for the adsorption capacity and the imprinting efficiency. The MICA had excellent flexibility, reversibility and stability. It promised high potential for the visual semi-quantitative detection of other explosives. - Highlights: • Molecularly imprinted colloidal array (MICA) was used to visually detect TNT. • The relationship of particle size, diffracted wavelength and color was discussed. • The adsorption capacity and imprinting efficiency of MICs were calculated. • MICA had short response time, high selectivity, good reversibility and stability. • MICA had high potential to be used in other customed visual explosive detection. - Abstract: We developed a photonic crystal (PhC) sensor for the quantification of 2,4,6-trinitrotoluene (TNT) in solution. Monodisperse (210 nm in diameter) molecularly imprinted colloidal particles (MICs) for TNT were prepared by the emulsion polymerization of methyl methacrylate and acrylamide in the presence of TNT as a template. The MICs were then self-assembled into close-packed opal PhC films. The adsorption capacity of the MICs for TNT was 64 mg TNT/g. The diffraction from the PhC depended on the TNT concentration in a methanol/water (3/2, v/v) potassium dihydrogen phosphate buffer solution (pH = 7.0, 30 mM). The limit of detection (LOD) of the sensor was 1.03 μg. The color of the molecularly imprinted colloidal array (MICA) changed from green to red with an 84 nm diffraction red shift when the TNT concentration increased to 20 mM. The sensor response time was 3 min. The PhC sensor was selective for TNT compared to similar compounds such as 2,4,6-trinitrophenol, 2,4-dinitrotoluene, 2,6-dinitrotoluene, 2-nitromesitylene, 4-nitrotoluene, 2-nitrotoluene, 1,3-dinitrobenzene, methylbenzene, 4-nitrophenol

  6. Visual detection of 2,4,6-trinitrotolune by molecularly imprinted colloidal array photonic crystal

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Wei [School of Chemical Engineering and Environment, Beijing Institute of Technology, Beijing, 100081 (China); Asher, Sanford A., E-mail: asher@pitt.edu [Department of Chemistry, University of Pittsburgh, Pittsburgh, PA 15260 (United States); Meng, Zihui, E-mail: m_zihui@yahoo.com [School of Chemical Engineering and Environment, Beijing Institute of Technology, Beijing, 100081 (China); Yan, Zequn [School of Chemical Engineering and Environment, Beijing Institute of Technology, Beijing, 100081 (China); Xue, Min, E-mail: minxue@bit.edu.cn [School of Chemical Engineering and Environment, Beijing Institute of Technology, Beijing, 100081 (China); Qiu, Lili, E-mail: qiulili@bit.edu.cn [School of Chemical Engineering and Environment, Beijing Institute of Technology, Beijing, 100081 (China); Yi, Da [School of Chemical Engineering and Environment, Beijing Institute of Technology, Beijing, 100081 (China)

    2016-10-05

    Graphical abstract: Molecularly imprinted colloidal array (MICA) was explored for the selective visual detection of TNT with color changing from green to red. And molecularly imprinted colloidal particles (MICs) were evaluated for the adsorption capacity and the imprinting efficiency. The MICA had excellent flexibility, reversibility and stability. It promised high potential for the visual semi-quantitative detection of other explosives. - Highlights: • Molecularly imprinted colloidal array (MICA) was used to visually detect TNT. • The relationship of particle size, diffracted wavelength and color was discussed. • The adsorption capacity and imprinting efficiency of MICs were calculated. • MICA had short response time, high selectivity, good reversibility and stability. • MICA had high potential to be used in other customed visual explosive detection. - Abstract: We developed a photonic crystal (PhC) sensor for the quantification of 2,4,6-trinitrotoluene (TNT) in solution. Monodisperse (210 nm in diameter) molecularly imprinted colloidal particles (MICs) for TNT were prepared by the emulsion polymerization of methyl methacrylate and acrylamide in the presence of TNT as a template. The MICs were then self-assembled into close-packed opal PhC films. The adsorption capacity of the MICs for TNT was 64 mg TNT/g. The diffraction from the PhC depended on the TNT concentration in a methanol/water (3/2, v/v) potassium dihydrogen phosphate buffer solution (pH = 7.0, 30 mM). The limit of detection (LOD) of the sensor was 1.03 μg. The color of the molecularly imprinted colloidal array (MICA) changed from green to red with an 84 nm diffraction red shift when the TNT concentration increased to 20 mM. The sensor response time was 3 min. The PhC sensor was selective for TNT compared to similar compounds such as 2,4,6-trinitrophenol, 2,4-dinitrotoluene, 2,6-dinitrotoluene, 2-nitromesitylene, 4-nitrotoluene, 2-nitrotoluene, 1,3-dinitrobenzene, methylbenzene, 4-nitrophenol

  7. Regression analysis for LED color detection of visual-MIMO system

    Science.gov (United States)

    Banik, Partha Pratim; Saha, Rappy; Kim, Ki-Doo

    2018-04-01

    Color detection from a light emitting diode (LED) array using a smartphone camera is very difficult in a visual multiple-input multiple-output (visual-MIMO) system. In this paper, we propose a method to determine the LED color using a smartphone camera by applying regression analysis. We employ a multivariate regression model to identify the LED color. After taking a picture of an LED array, we select the LED array region, and detect the LED using an image processing algorithm. We then apply the k-means clustering algorithm to determine the number of potential colors for feature extraction of each LED. Finally, we apply the multivariate regression model to predict the color of the transmitted LEDs. In this paper, we show our results for three types of environmental light condition: room environmental light, low environmental light (560 lux), and strong environmental light (2450 lux). We compare the results of our proposed algorithm from the analysis of training and test R-Square (%) values, percentage of closeness of transmitted and predicted colors, and we also mention about the number of distorted test data points from the analysis of distortion bar graph in CIE1931 color space.

  8. Evaluation of the limits of visual detection of image misregistration in a brain fluorine-18 fluorodeoxyglucose PET-MRI study

    International Nuclear Information System (INIS)

    Wong, J.C.H.; Studholme, C.; Hawkes, D.J.; Maisey, M.N.

    1997-01-01

    In routine clinical work, registration accuracy is assessed by visual inspection. However, the accuracy of visual assessment of registration has not been evaluated. This study establishes the limits of visual detection of misregistration in a registered brain fluorine-18 fluorodeoxyglucose positron emission tomography to magnetic resonance image volume. The ''best'' registered image volume was obtained by automatic registration using mutual information optimization. Translational movements by 1 mm, 2 mm, 3 mm and 4 mm, and rotational movements by 1 , 2 , 3 and 4 in the positive and negative directions in the x- (lateral), y- (anterior-posterior) and z- (axial) axes were introduced to this standard. These 48 images plus six ''best'' registered images were presented in random sequence to five observers for visual categorization of registration accuracy. No observer detected a definite misregistration in the ''best'' registered image. Evaluation for inter-observer variation using observer pairings showed a high percentage of agreement in assigned categories for both translational and rotational misregistrations. Assessment of the limits of detection of misregistration showed that a 2-mm translational misregistration was detectable by all observers in the x- and y-axes and 3-mm translational misregistration in the z-axis. With rotational misregistrations, rotation around the z-axis was detectable by all at 2 rotation whereas rotation around the y-axis was detected at 3-4 . Rotation around the x-axis was not symmetric with a positive rotation being identified at 2 whereas negative rotation was detected by all only at 4 . Therefore, visual analysis appears to be a sensitive and practical means to assess image misregistration accuracy. The awareness of the limits of visual detection of misregistration will lead to increase care when evaluating registration quality in both research and clinical settings. (orig.). With 6 figs., 3 tabs

  9. Real-time detection and discrimination of visual perception using electrocorticographic signals

    Science.gov (United States)

    Kapeller, C.; Ogawa, H.; Schalk, G.; Kunii, N.; Coon, W. G.; Scharinger, J.; Guger, C.; Kamada, K.

    2018-06-01

    Objective. Several neuroimaging studies have demonstrated that the ventral temporal cortex contains specialized regions that process visual stimuli. This study investigated the spatial and temporal dynamics of electrocorticographic (ECoG) responses to different types and colors of visual stimulation that were presented to four human participants, and demonstrated a real-time decoder that detects and discriminates responses to untrained natural images. Approach. ECoG signals from the participants were recorded while they were shown colored and greyscale versions of seven types of visual stimuli (images of faces, objects, bodies, line drawings, digits, and kanji and hiragana characters), resulting in 14 classes for discrimination (experiment I). Additionally, a real-time system asynchronously classified ECoG responses to faces, kanji and black screens presented via a monitor (experiment II), or to natural scenes (i.e. the face of an experimenter, natural images of faces and kanji, and a mirror) (experiment III). Outcome measures in all experiments included the discrimination performance across types based on broadband γ activity. Main results. Experiment I demonstrated an offline classification accuracy of 72.9% when discriminating among the seven types (without color separation). Further discrimination of grey versus colored images reached an accuracy of 67.1%. Discriminating all colors and types (14 classes) yielded an accuracy of 52.1%. In experiment II and III, the real-time decoder correctly detected 73.7% responses to face, kanji and black computer stimuli and 74.8% responses to presented natural scenes. Significance. Seven different types and their color information (either grey or color) could be detected and discriminated using broadband γ activity. Discrimination performance maximized for combined spatial-temporal information. The discrimination of stimulus color information provided the first ECoG-based evidence for color-related population

  10. Early auditory change detection implicitly facilitated by ignored concurrent visual change during a Braille reading task.

    Science.gov (United States)

    Aoyama, Atsushi; Haruyama, Tomohiro; Kuriki, Shinya

    2013-09-01

    Unconscious monitoring of multimodal stimulus changes enables humans to effectively sense the external environment. Such automatic change detection is thought to be reflected in auditory and visual mismatch negativity (MMN) and mismatch negativity fields (MMFs). These are event-related potentials and magnetic fields, respectively, evoked by deviant stimuli within a sequence of standard stimuli, and both are typically studied during irrelevant visual tasks that cause the stimuli to be ignored. Due to the sensitivity of MMN/MMF to potential effects of explicit attention to vision, however, it is unclear whether multisensory co-occurring changes can purely facilitate early sensory change detection reciprocally across modalities. We adopted a tactile task involving the reading of Braille patterns as a neutral ignore condition, while measuring magnetoencephalographic responses to concurrent audiovisual stimuli that were infrequently deviated either in auditory, visual, or audiovisual dimensions; 1000-Hz standard tones were switched to 1050-Hz deviant tones and/or two-by-two standard check patterns displayed on both sides of visual fields were switched to deviant reversed patterns. The check patterns were set to be faint enough so that the reversals could be easily ignored even during Braille reading. While visual MMFs were virtually undetectable even for visual and audiovisual deviants, significant auditory MMFs were observed for auditory and audiovisual deviants, originating from bilateral supratemporal auditory areas. Notably, auditory MMFs were significantly enhanced for audiovisual deviants from about 100 ms post-stimulus, as compared with the summation responses for auditory and visual deviants or for each of the unisensory deviants recorded in separate sessions. Evidenced by high tactile task performance with unawareness of visual changes, we conclude that Braille reading can successfully suppress explicit attention and that simultaneous multisensory changes can

  11. Multirapid Serial Visual Presentation Framework for EEG-Based Target Detection

    Directory of Open Access Journals (Sweden)

    Zhimin Lin

    2017-01-01

    Full Text Available Target image detection based on a rapid serial visual presentation (RSVP paradigm is a typical brain-computer interface system with various applications, such as image retrieval. In an RSVP paradigm, a P300 component is detected to determine target images. This strategy requires high-precision single-trial P300 detection methods. However, the performance of single-trial detection methods is relatively lower than that of multitrial P300 detection methods. Image retrieval based on multitrial P300 is a new research direction. In this paper, we propose a triple-RSVP paradigm with three images being presented simultaneously and a target image appearing three times. Thus, multitrial P300 classification methods can be used to improve detection accuracy. In this study, these mechanisms were extended and validated, and the characteristics of the multi-RSVP framework were further explored. Two different P300 detection algorithms were also utilized in multi-RSVP to demonstrate that the scheme is universally applicable. Results revealed that the detection accuracy of the multi-RSVP paradigm was higher than that of the standard RSVP paradigm. The results validate the effectiveness of the proposed method, and this method can provide a whole new idea in the field of EEG-based target detection.

  12. A nanoparticle-based sensor for visual detection of multiple mutations

    Energy Technology Data Exchange (ETDEWEB)

    Elenis, Dimitrios S; Ioannou, Penelope C [Department of Chemistry, University of Athens, Athens 15771 (Greece); Christopoulos, Theodore K, E-mail: ioannou@chem.uoa.gr [Department of Chemistry, University of Patras, Patras 26500 (Greece)

    2011-04-15

    Disposable dipstick-type DNA biosensors in the form of lateral flow strips are particularly useful for genotyping in a small laboratory or for field testing due to their simplicity, low cost and portability. Their unique advantage is that they enable visual detection in minutes without the use of instruments. In addition, the dry-reagent format minimizes the pipetting, incubation and washing steps. In this work, we significantly enhance the multiplexing capabilities of lateral flow strip biosensors without compromising their simplicity. Multiplex genotyping is carried out by polymerase chain reaction (PCR) followed by a single primer extension reaction for all target alleles, in which a primer is extended and biotin is incorporated only if it is perfectly complementary to the target. Multiallele detection is achieved by multiple test spots on the membrane of the sensor, each comprising a suspension of polystyrene microspheres functionalized with capture probes. The products of the primer extension reaction hybridize, through specific sequence tags, to the capture probes and are visualized by using antibiotin-conjugated gold nanoparticles. This design enables accommodation of multiple spots in a small area because the microspheres are trapped in the fibres of the membrane and remain fixed in site without any diffusion. Furthermore, the detectability is improved because the hybrids are exposed on the surface of the trapped microspheres rather than inside the pores of the membrane. We demonstrate the specificity and performance of the biosensor for multiallele genotyping.

  13. A nanoparticle-based sensor for visual detection of multiple mutations

    International Nuclear Information System (INIS)

    Elenis, Dimitrios S; Ioannou, Penelope C; Christopoulos, Theodore K

    2011-01-01

    Disposable dipstick-type DNA biosensors in the form of lateral flow strips are particularly useful for genotyping in a small laboratory or for field testing due to their simplicity, low cost and portability. Their unique advantage is that they enable visual detection in minutes without the use of instruments. In addition, the dry-reagent format minimizes the pipetting, incubation and washing steps. In this work, we significantly enhance the multiplexing capabilities of lateral flow strip biosensors without compromising their simplicity. Multiplex genotyping is carried out by polymerase chain reaction (PCR) followed by a single primer extension reaction for all target alleles, in which a primer is extended and biotin is incorporated only if it is perfectly complementary to the target. Multiallele detection is achieved by multiple test spots on the membrane of the sensor, each comprising a suspension of polystyrene microspheres functionalized with capture probes. The products of the primer extension reaction hybridize, through specific sequence tags, to the capture probes and are visualized by using antibiotin-conjugated gold nanoparticles. This design enables accommodation of multiple spots in a small area because the microspheres are trapped in the fibres of the membrane and remain fixed in site without any diffusion. Furthermore, the detectability is improved because the hybrids are exposed on the surface of the trapped microspheres rather than inside the pores of the membrane. We demonstrate the specificity and performance of the biosensor for multiallele genotyping.

  14. Positive mood broadens visual attention to positive stimuli.

    Science.gov (United States)

    Wadlinger, Heather A; Isaacowitz, Derek M

    2006-03-01

    In an attempt to investigate the impact of positive emotions on visual attention within the context of Fredrickson's (1998) broaden-and-build model, eye tracking was used in two studies to measure visual attentional preferences of college students (n=58, n=26) to emotional pictures. Half of each sample experienced induced positive mood immediately before viewing slides of three similarly-valenced images, in varying central-peripheral arrays. Attentional breadth was determined by measuring the percentage viewing time to peripheral images as well as by the number of visual saccades participants made per slide. Consistent with Fredrickson's theory, the first study showed that individuals induced into positive mood fixated more on peripheral stimuli than did control participants; however, this only held true for highly-valenced positive stimuli. Participants under induced positive mood also made more frequent saccades for slides of neutral and positive valence. A second study showed that these effects were not simply due to differences in emotional arousal between stimuli. Selective attentional broadening to positive stimuli may act both to facilitate later building of resources as well as to maintain current positive affective states.

  15. AllelicImbalance: An R/ bioconductor package for detecting, managing, and visualizing allele expression imbalance data from RNA sequencing

    DEFF Research Database (Denmark)

    Gådin, Jesper R.; van't Hooft, Ferdinand M.; Eriksson, Per

    2015-01-01

    the possible biases. Results: We present AllelicImblance, a software program that is designed to detect, manage, and visualize allelic imbalances comprehensively. The purpose of this software is to allow users to pose genetic questions in any RNA sequencing experiment quickly, enhancing the general utility...... of RNA sequencing. The visualization features can reveal notable, non-trivial allelic imbalance behavior over specific regions, such as exons. Conclusions: The software provides a complete framework to perform allelic imbalance analyses of aligned RNA sequencing data, from detection to visualization...

  16. Recovery of visual-field defects after occipital lobe infarction: a perimetric study.

    Science.gov (United States)

    Çelebisoy, Mehmet; Çelebisoy, Neşe; Bayam, Ece; Köse, Timur

    2011-06-01

    To assess the temporal course of homonymous visual-field defects due to occipital lobe infarction, by using automated perimetry. 32 patients with ischaemic infarction of the occipital lobe were studied prospectively, using a Humphrey Visual Field Analyser II. The visual field of each eye was divided into central, paracentral and peripheral zones. The mean visual sensitivity of each zone was calculated and used for the statistical analysis. The results of the initial examination, performed within 2 weeks of stroke, were compared with the results of the sixth-month control. The lesions were assigned to the localisations, optic radiation, striate cortex, occipital pole and occipital convexity, by MRI. A statistically significant improvement was noted, especially for the lower quadrants. Lesions of the occipital pole and convexity were not significantly associated with visual-field recovery. However, involvement of the striate cortex and extensive lesions involving all the areas studied was significantly associated with poor prognosis. Homonymous visual-field defects in our patients improved within 6 months. Restoration of the lower quadrants and especially the peripheral zones was noted. Incomplete damage to the striate cortex, which has a varying pattern of vascular supply, could explain this finding. Magnification factor theory, which is the increment of the receptive-field size of striate cortex cells with visual-field eccentricity, may explain the more significant improvement in the peripheral zones.

  17. Detecting delay in visual feedback of an action as a monitor of self recognition.

    Science.gov (United States)

    Hoover, Adria E N; Harris, Laurence R

    2012-10-01

    How do we distinguish "self" from "other"? The correlation between willing an action and seeing it occur is an important cue. We exploited the fact that this correlation needs to occur within a restricted temporal window in order to obtain a quantitative assessment of when a body part is identified as "self". We measured the threshold and sensitivity (d') for detecting a delay between movements of the finger (of both the dominant and non-dominant hands) and visual feedback as seen from four visual perspectives (the natural view, and mirror-reversed and/or inverted views). Each trial consisted of one presentation with minimum delay and another with a delay of between 33 and 150 ms. Participants indicated which presentation contained the delayed view. We varied the amount of efference copy available for this task by comparing performances for discrete movements and continuous movements. Discrete movements are associated with a stronger efference copy. Sensitivity to detect asynchrony between visual and proprioceptive information was significantly higher when movements were viewed from a "plausible" self perspective compared with when the view was reversed or inverted. Further, we found differences in performance between dominant and non-dominant hand finger movements across the continuous and single movements. Performance varied with the viewpoint from which the visual feedback was presented and on the efferent component such that optimal performance was obtained when the presentation was in the normal natural orientation and clear efferent information was available. Variations in sensitivity to visual/non-visual temporal incongruence with the viewpoint in which a movement is seen may help determine the arrangement of the underlying visual representation of the body.

  18. Trichloropropane and dichlorohydrin associated with painful peripheral neurotoxicity.

    Science.gov (United States)

    Shi, Xiaobing; Yu, Shengyuan

    2013-10-01

    Trichloropropane (TCP) and dichlorohydrin are widely used in industrial production; however, TCP and dichlorohydrin poisoning are rarely encountered in clinical practice. There have been no cases of peripheral neurotoxicity previously reported. A cluster of 23 patients who had been exposed to high levels of TCP and dichlorohydrin presented with painful peripheral neuropathy, and the pain was assessed using a visual analogue scale (VAS). Nerve conduction studies (NCS) were performed in all patients. All patients demonstrated symmetrical pin-prick pain in a stocking distribution in the lower limbs, with VAS scores between 3 and 10, with an average score of 6.8. NCS showed a mild mixture of axonal and demyelinating sensorimotor polyneuropathy in 14 of the 23 patients. After administration of standard neuropathic pain medication, pain was relieved in most patients. Painful peripheral neuropathy was the primary symptom observed in our patients, which differs from clinical and animal model reports of TCP or dichlorohydrin poisoning. However, the pathogenesis remains unidentified. TCP may be added to the list of industrial products that are toxic to the peripheral sensory nerves. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Exogenously-driven perceptual alternation of a bistable image: From the perspective of the visual change detection process.

    Science.gov (United States)

    Urakawa, Tomokazu; Aragaki, Tomoya; Araki, Osamu

    2017-07-13

    Based on the predictive coding framework, the present behavioral study focused on the automatic visual change detection process, which yields a concomitant prediction error, as one of the visual processes relevant to the exogenously-driven perceptual alternation of a bistable image. According to this perspective, we speculated that the automatic visual change detection process with an enhanced prediction error is relevant to the greater induction of exogenously-driven perceptual alternation and attempted to test this hypothesis. A modified version of the oddball paradigm was used based on previous electroencephalographic studies on visual change detection, in which the deviant and standard defined by the bar's orientation were symmetrically presented around a continuously presented Necker cube (a bistable image). By manipulating inter-stimulus intervals and the number of standard repetitions, we set three experimental blocks: HM, IM, and LM blocks, in which the strength of the prediction error to the deviant relative to the standard was expected to gradually decrease in that order. The results obtained showed that the deviant significantly increased perceptual alternation of the Necker cube over that by the standard from before to after the presentation of the deviant. Furthermore, the differential proportion of the deviant relative to the standard significantly decreased from the HM block to the IM and LM blocks. These results are consistent with our hypothesis, supporting the involvement of the automatic visual change detection process in the induction of exogenously-driven perceptual alternation. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Mobility scooter driving ability in visually impaired individuals.

    Science.gov (United States)

    Cordes, Christina; Heutink, Joost; Brookhuis, Karel A; Brouwer, Wiebo H; Melis-Dankers, Bart J M

    2018-06-01

    To investigate how well visually impaired individuals can learn to use mobility scooters and which parts of the driving task deserve special attention. A mobility scooter driving skill test was developed to compare driving skills (e.g. reverse driving, turning) between 48 visually impaired (very low visual acuity = 14, low visual acuity = 10, peripheral field defects = 11, multiple visual impairments = 13) and 37 normal-sighted controls without any prior experience with mobility scooters. Performance on this test was rated on a three-point scale. Furthermore, the number of extra repetitions on the different elements were noted. Results showed that visually impaired participants were able to gain sufficient driving skills to be able to use mobility scooters. Participants with visual field defects combined with low visual acuity showed most problems learning different skills and needed more training. Reverse driving and stopping seemed to be most difficult. The present findings suggest that visually impaired individuals are able to learn to drive mobility scooters. Mobility scooter allocators should be aware that these individuals might need more training on certain elements of the driving task. Implications for rehabilitation Visual impairments do not necessarily lead to an inability to acquire mobility scooter driving skills. Individuals with peripheral field defects (especially in combination with reduced visual acuity) need more driving ability training compared to normal-sighted people - especially to accomplish reversing. Individual assessment of visually impaired people is recommended, since participants in this study showed a wide variation in ability to learn driving a mobility scooter.

  1. Unsold is unseen … or is it? Examining the role of peripheral vision in the consumer choice process using eye-tracking methodology.

    Science.gov (United States)

    Wästlund, Erik; Shams, Poja; Otterbring, Tobias

    2018-01-01

    In visual marketing, the truism that "unseen is unsold" means that products that are not noticed will not be sold. This truism rests on the idea that the consumer choice process is heavily influenced by visual search. However, given that the majority of available products are not seen by consumers, this article examines the role of peripheral vision in guiding attention during the consumer choice process. In two eye-tracking studies, one conducted in a lab facility and the other conducted in a supermarket, the authors investigate the role and limitations of peripheral vision. The results show that peripheral vision is used to direct visual attention when discriminating between target and non-target objects in an eye-tracking laboratory. Target and non-target similarity, as well as visual saliency of non-targets, constitute the boundary conditions for this effect, which generalizes from instruction-based laboratory tasks to preference-based choice tasks in a real supermarket setting. Thus, peripheral vision helps customers to devote a larger share of attention to relevant products during the consumer choice process. Taken together, the results show how the creation of consideration set (sets of possible choice options) relies on both goal-directed attention and peripheral vision. These results could explain how visually similar packaging positively influences market leaders, while making novel brands almost invisible on supermarket shelves. The findings show that even though unsold products might be unseen, in the sense that they have not been directly observed, they might still have been evaluated and excluded by means of peripheral vision. This article is based on controlled lab experiments as well as a field study conducted in a complex retail environment. Thus, the findings are valid both under controlled and ecologically valid conditions. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. Can DMCO Detect Visual Field Loss in Neurological Patients? A Secondary Validation Study

    DEFF Research Database (Denmark)

    Olsen, Ane Sophie; Steensberg, Alvilda Thougaard; la Cour, Morten

    2017-01-01

    Unrecognized visual field loss is caused by a range of blinding eye conditions as well as serious brain diseases. The commonest cause of asymptomatic visual field loss is glaucoma. No screening tools have been proven cost-effective. Damato Multifixation Campimetry Online (DMCO), an inexpensive...... online test, has been evaluated as a future cost-beneficial tool to detect glaucoma. To further validate DMCO, this study aimed to test DMCO in a preselected population with neurological visual field loss. Methods : The study design was an evaluation of a diagnostic test. Patients were included...... if they had undergone surgery for epilepsy during 2011-2014, resulting in visual field loss. They were examined with DMCO and results were compared with those obtained with the Humphrey Field Analyzer (30:2 SITA-Fast). DMCO sensitivity and specificity were estimated with 95% confidence intervals. Results...

  3. Demographic processes of developmentally peripheral areas in Hungary

    Directory of Open Access Journals (Sweden)

    Pénzes János

    2015-01-01

    Full Text Available The current study investigates the demographic processes and challenges of the Hungarian developmentally peripheral settlements. Demographic challenges can be regarded as important consequences of the social and economic disadvantages in spatial terms. However, the interrelating negative demographic tendencies cause even more backward situation blocking or hindering the development. The objective of the current analysis is to discover the demographic characteristics of the peripheral settlements, to detect the spatial disparities and to point out the correlation between backwardness and the investigated demographic phenomena with the help of the census databases 1980-2011 and local datasets on Roma population. Using methods of multivariate statistical analysis, seven indicators were selected in order to achieve the goals of the paper. Backward areas are primarily characterized by population decrease with significant disparities, but there were growing communities among them as well. Some small villages in Northern and Southwestern Hungary will foreseeably face complete depopulation within few years. Primarily small sized villages faced intense decrease in rate of natural change, but dynamic population growth was also detected. Migration loss tends to correlate with the extent of peripherality, as increasing values of migration balance accompany decreasing ratio of peripheral settlements in the area. The ratio of elderly population shows an expressively two-faced character, with the extremely aging and very juvenile settlements. The ratios of Roma population reflect the scale of peripherality. Extended ethnic change could be predicted in Northeastern and Southwestern Hungary and near the Middle Tisza valley. Presented demographic processes will make the backwardness of most of the peripheral settlements stable.

  4. Screening for Electrophysiological Abnormalities in Chronic Hepatitis C Infection: Peripheral Neuropathy and Optic Neuropathy.

    Science.gov (United States)

    Köşkderelioğlu, Aslı; Ortan, Pınar; Ari, Alpay; Gedizlioğlu, Muhteşem

    2016-03-01

    To investigate the existence of peripheral and optic neuropathies in asymptomatic individuals with hepatitis C infection. Thirty consecutive patients who were followed in a hepatitis C outpatient clinic were recruited for electrophysiological evaluation together with 30 age- and gender-compatible healthy controls. All patients had a detailed neurological examination. The information regarding the disease duration and management with interferons were collected. Nerve conduction studies and visual evoked potentials (VEP) were recorded in all subjects. The results of the patient and control groups were statistically compared. Of the patients with hepatitis C infection, 16 were females and 14 males. The mean age was 57.5 years, and the average disease duration was 6.43 years. The P100 latencies in the patient group were within normal limits, while the amplitudes were meaningfully small by comparison with the controls. There were some abnormalities in the nerve conduction studies of 15 patients. Sensorial neuropathy was detected in two patients, sensorimotor polyneuropathy in four, carpal tunnel syndrome in seven, and carpal tunnel syndrome and sensorimotor polyneuropathy as comorbid states in another two patients. The nerve conduction studies and VEP parameters were entirely normal in the control group. Hepatitis C-related neurological abnormalities may occur both in the central and peripheral nervous system. Mononeuritis multiplex, sensorial axonal neuropathy, and multiple mononeuropathies are some of the presentations of the peripheral nervous system involvement. The mode of infection is considered to be via vasculitic mechanisms. In addition, optic neuropathy is a known complication of interferon treatment. Autoantibodies, cytokines, chemokines, and cryoglobulins are accused to play roles in the pathogenesis. In this study, we investigated the involvement of the peripheral nervous system and optic nerves in a group of patients with hepatitis C. The results were in

  5. Visual detection of West Nile virus using reverse transcription loop-mediated isothermal amplification combined with a vertical flow visualization strip

    Directory of Open Access Journals (Sweden)

    Zengguo eCao

    2016-04-01

    Full Text Available West Nile virus (WNV causes a severe zoonosis, which can lead to a large number of casualties and considerable economic losses. A rapid and accurate identification methodfor WNV for use in field laboratories is urgently needed. Here, a method utilizing reverse transcription loop-mediated isothermal amplification combined with a vertical flow visualization strip (RT-LAMP-VF was developed to detect the envelope (E gene of WNV. The RT-LAMP-VF assay could detect 102 copies/μl ofan WNV RNA standard using a 40 min amplification reaction followed by a 2 min incubationof the amplification product on the visualization strip, and no cross-reaction with other closely related members of theFlavivirus genus was observed. The assay was further evaluated using cells and mouse brain tissues infected with a recombinant rabies virus expressing the E protein of WNV.The assay produced sensitivities of 101.5TCID50/ml and 101.33 TCID50/ml for detection of the recombinant virus in the cells and brain tissues, respectively. Overall, the RT-LAMP-VF assay developed in this study is rapid, simple and effective, and it is therefore suitable for clinical application in the field.

  6. Edge Detection Based On the Characteristic of Primary Visual Cortex Cells

    Science.gov (United States)

    Zhu, M. M.; Xu, Y. L.; Ma, H. Q.

    2018-01-01

    Aiming at the problem that it is difficult to balance the accuracy of edge detection and anti-noise performance, and referring to the dynamic and static perceptions of the primary visual cortex (V1) cells, a V1 cell model is established to perform edge detection. A spatiotemporal filter is adopted to simulate the receptive field of V1 simple cells, the model V1 cell is obtained after integrating the responses of simple cells by half-wave rectification and normalization, Then the natural image edge is detected by using static perception of V1 cells. The simulation results show that, the V1 model can basically fit the biological data and has the universality of biology. What’s more, compared with other edge detection operators, the proposed model is more effective and has better robustness

  7. Intraarterial digital subtraction angiography of peripheral arteries with isotonic contrast material

    International Nuclear Information System (INIS)

    Yashiro, Naobumi; Itai, Yuji; Ohtomo, Kuni; Furui, Shigeru; Iio, Masahiro

    1984-01-01

    Intraarterial digital subtraction angiography (IADSA) of peripheral arteries with isotonic contrast material, which was prepared by diluting meglumine amidotrizoate (65% Angiografin), was performed in ten patients. In six, both IADSA and conventional screen-film arteriography were performed for comparison. Painless peripheral arteriography was achieved by IADSA with isotonic contrast material. Five IADSAs were safely done on an outpatient basis. Visualization of arteries by IADSA was satisfactory, but the details of smaller arteries were better shown by screen-film arteriography. Visualization of faint stains was better in IADSA. The authors believe that IADSA with isotonic contrast material is a method of choice for the diagnosis of vascular diseases and tumorous conditions of extremities, as well as for the purpose of preoperative vascular mapping. It is safely performed with smaller dose of contrast material on outpatient basis, and with less discomfort and cost for the patient. (author)

  8. Differential pain modulation in patients with peripheral neuropathic pain and fibromyalgia.

    Science.gov (United States)

    Gormsen, Lise; Bach, Flemming W; Rosenberg, Raben; Jensen, Troels S

    2017-12-29

    Background The definition of neuropathic pain has recently been changed by the International Association for the Study of Pain. This means that conditions such as fibromyalgia cannot, as sometimes discussed, be included in the neuropathic pain conditions. However, fibromyalgia and peripheral neuropathic pain share common clinical features such as spontaneous pain and hypersensitivity to external stimuli. Therefore, it is of interest to directly compare the conditions. Material and methods In this study we directly compared the pain modulation in neuropathic pain versus fibromyalgia by recording responses to a cold pressor test in 30 patients with peripheral neuropathic pain, 28 patients with fibromyalgia, and 26 pain-free age-and gender-matched healthy controls. Patients were asked to rate their spontaneous pain on a visual analog scale (VAS (0-100 mm) immediately before and immediately after the cold pressor test. Furthermore the duration (s) of extremity immersion in cold water was used as a measure of the pain tolerance threshold, and the perceived pain intensity at pain tolerance on the VAS was recorded on the extremity in the water after the cold pressor test. In addition, thermal (thermo tester) and mechanical stimuli (pressure algometer) were used to determine sensory detection, pain detection, and pain tolerance thresholds in different body parts. All sensory tests were done by the same examiner, in the same room, and with each subject in a supine position. The sequence of examinations was the following: (1) reaction time, (2) pressure thresholds, (3) thermal thresholds, and (4) cold pressor test. Reaction time was measured to ensure that psychomotoric inhibitions did not influence pain thresholds. Results Pain modulation induced by a cold pressor test reduced spontaneous pain by 40% on average in neuropathic pain patients, but increased spontaneous pain by 2.6% in fibromyalgia patients. This difference between fibromyalgia and neuropathic pain patients was

  9. Implementation of a General Real-Time Visual Anomaly Detection System Via Soft Computing

    Science.gov (United States)

    Dominguez, Jesus A.; Klinko, Steve; Ferrell, Bob; Steinrock, Todd (Technical Monitor)

    2001-01-01

    The intelligent visual system detects anomalies or defects in real time under normal lighting operating conditions. The application is basically a learning machine that integrates fuzzy logic (FL), artificial neural network (ANN), and generic algorithm (GA) schemes to process the image, run the learning process, and finally detect the anomalies or defects. The system acquires the image, performs segmentation to separate the object being tested from the background, preprocesses the image using fuzzy reasoning, performs the final segmentation using fuzzy reasoning techniques to retrieve regions with potential anomalies or defects, and finally retrieves them using a learning model built via ANN and GA techniques. FL provides a powerful framework for knowledge representation and overcomes uncertainty and vagueness typically found in image analysis. ANN provides learning capabilities, and GA leads to robust learning results. An application prototype currently runs on a regular PC under Windows NT, and preliminary work has been performed to build an embedded version with multiple image processors. The application prototype is being tested at the Kennedy Space Center (KSC), Florida, to visually detect anomalies along slide basket cables utilized by the astronauts to evacuate the NASA Shuttle launch pad in an emergency. The potential applications of this anomaly detection system in an open environment are quite wide. Another current, potentially viable application at NASA is in detecting anomalies of the NASA Space Shuttle Orbiter's radiator panels.

  10. Peripheral neuropathy

    Science.gov (United States)

    ... peripheral; Neuritis - peripheral; Nerve disease; Polyneuropathy; Chronic pain - peripheral neuropathy ... Philadelphia, PA: Elsevier; 2016:chap 107. Shy ME. Peripheral neuropathies. In: Goldman L, Schafer AI, eds. Goldman's Cecil ...

  11. Detecting and Remembering Simultaneous Pictures in a Rapid Serial Visual Presentation

    Science.gov (United States)

    Potter, Mary C.; Fox, Laura F.

    2009-01-01

    Viewers can easily spot a target picture in a rapid serial visual presentation (RSVP), but can they do so if more than 1 picture is presented simultaneously? Up to 4 pictures were presented on each RSVP frame, for 240 to 720 ms/frame. In a detection task, the target was verbally specified before each trial (e.g., "man with violin"); in a…

  12. An integrated theory of attention and decision making in visual signal detection.

    Science.gov (United States)

    Smith, Philip L; Ratcliff, Roger

    2009-04-01

    The simplest attentional task, detecting a cued stimulus in an otherwise empty visual field, produces complex patterns of performance. Attentional cues interact with backward masks and with spatial uncertainty, and there is a dissociation in the effects of these variables on accuracy and on response time. A computational theory of performance in this task is described. The theory links visual encoding, masking, spatial attention, visual short-term memory (VSTM), and perceptual decision making in an integrated dynamic framework. The theory assumes that decisions are made by a diffusion process driven by a neurally plausible, shunting VSTM. The VSTM trace encodes the transient outputs of early visual filters in a durable form that is preserved for the time needed to make a decision. Attention increases the efficiency of VSTM encoding, either by increasing the rate of trace formation or by reducing the delay before trace formation begins. The theory provides a detailed, quantitative account of attentional effects in spatial cuing tasks at the level of response accuracy and the response time distributions. (c) 2009 APA, all rights reserved

  13. Gene Expression Profiling of Peripheral Blood From Kidney Transplant Recipients for the Early Detection of Digestive System Cancer.

    Science.gov (United States)

    Kusaka, M; Okamoto, M; Takenaka, M; Sasaki, H; Fukami, N; Kataoka, K; Ito, T; Kenmochi, T; Hoshinaga, K; Shiroki, R

    2017-06-01

    Kidney transplant recipients are at increased risk of developing cancer in comparison with the general population. To effectively manage post-transplantation malignancies, it is essential to proactively monitor patients. A long-term intensive screening program was associated with a reduced incidence of cancer after transplantation. This study evaluated the usefulness of the gene expression profiling of peripheral blood samples obtained from kidney transplant patients and adopted a screening test for detecting cancer of the digestive system (gastric, colon, pancreas, and biliary tract). Nineteen patients were included in this study and a total of 53 gene expression screening tests were performed. The gene expression profiles of blood-delivered total RNA and whole genome human gene expression profiles were obtained. We investigated the expression levels of 2665 genes associated with digestive cancers and counted the number of genes in which expression was altered. A hierarchical clustering analysis was also performed. The final prediction of the cancer possibility was determined according to an algorithm. The number of genes in which expression was altered was significantly increased in the kidney transplant recipients in comparison with the general population (1091 ± 63 vs 823 ± 94; P = .0024). The number of genes with altered expression decreased after the induction of mechanistic target of rapamycin (mTOR) inhibitor (1484 ± 227 vs 883 ± 154; P = .0439). No cases of possible digestive cancer were detected in this study period. The gene expression profiling of peripheral blood samples may be a useful and noninvasive diagnostic tool that allows for the early detection of cancer of the digestive system. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Unipedal stance testing in the assessment of peripheral neuropathy.

    Science.gov (United States)

    Hurvitz, E A; Richardson, J K; Werner, R A

    2001-02-01

    To define further the relation between unipedal stance testing and peripheral neuropathy. Prospective cohort. Electroneuromyography laboratory of a Veterans Affairs medical center and a university hospital. Ninety-two patients referred for lower extremity electrodiagnostic studies. A standardized history and physical examination designed to detect peripheral neuropathy, 3 trials of unipedal stance, and electrodiagnostic studies. Peripheral neuropathy was identified by electrodiagnostic testing in 32%. These subjects had a significantly shorter (p unipedal stance time (15.7s, longest of 3 trials) than the patients without peripheral neuropathy (37.1s). Abnormal unipedal stance time (unipedal stance time had a negative predictive value of 90%. Abnormal unipedal stance time was associated with an increased risk of having peripheral neuropathy on univariate analysis (odds ratio = 8.8, 95% confidence interval = 2.5--31), and was the only significant predictor of peripheral neuropathy in the regression model. Aspects of the neurologic examination did not add to the regression model compared with abnormal unipedal stance time. Unipedal stance testing is useful in the clinical setting both to identify and to exclude the presence of peripheral neuropathy.

  15. Investigation of the sensitivity of a cross-polarized light visualization system to detect subclinical erythema and dryness in women with vulvovaginitis.

    Science.gov (United States)

    Farage, Miranda A; Singh, Mukul; Ledger, William J

    2009-07-01

    An enhanced visualization technique using polarized light (Syris v600 enhanced visualization system; Syris Scientific LLC, Gray, ME) detects surface and subsurface ( approximately 1 mm depth) inflammation. We sought to compare the Syris v600 system with unaided visual inspection and colposcopy of the female genitalia. Erythema and dryness of the vulva, introitus, vagina, and cervix were visualized and scored by each method in patients with and without vulvitis. Subsurface visualization was more sensitive in detecting genital erythema and dryness at all sites whether or not symptoms were present. Subsurface inflammation of the introitus, vagina, and cervix only was detected uniquely in women with vulvar vestibulitis syndrome (VVS). A subset of women presenting with VVS exhibited subclinical inflammation of the vulva vestibule and vagina (designated VVS/lichen sclerosus subgroup). Enhanced visualization of the genital epithelial subsurface with cross-polarized light may assist in diagnosing subclinical inflammation in vulvar conditions heretofore characterized as sensory syndromes.

  16. Liposomes to target peripheral neurons and Schwann cells.

    Directory of Open Access Journals (Sweden)

    Sooyeon Lee

    Full Text Available While a wealth of literature for tissue-specific liposomes is emerging, optimal formulations to target the cells of the peripheral nervous system (PNS are lacking. In this study, we asked whether a novel formulation of phospholipid-based liposomes could be optimized for preferential uptake by microvascular endothelia, peripheral neurons and Schwann cells. Here, we report a unique formulation consisting of a phospholipid, a polymer surfactant and cholesterol that result in enhanced uptake by targeted cells. Using fluorescently labeled liposomes, we followed particle internalization and trafficking through a distinct route from dextran and escape from degradative compartments, such as lysosomes. In cultures of non-myelinating Schwann cells, liposomes associate with the lipid raft marker Cholera toxin, and their internalization is inhibited by disruption of lipid rafts or actin polymerization. In contrast, pharmacological inhibition of clathrin-mediated endocytosis does not significantly impact liposome entry. To evaluate the efficacy of liposome targeting in tissues, we utilized myelinating explant cultures of dorsal root ganglia and isolated diaphragm preparations, both of which contain peripheral neurons and myelinating Schwann cells. In these models, we detected preferential liposome uptake into neurons and glial cells in comparison to surrounding muscle tissue. Furthermore, in vivo liposome administration by intramuscular or intravenous injection confirmed that the particles were delivered to myelinated peripheral nerves. Within the CNS, we detected the liposomes in choroid epithelium, but not in myelinated white matter regions or in brain parenchyma. The described nanoparticles represent a novel neurophilic delivery vehicle for targeting small therapeutic compounds, biological molecules, or imaging reagents into peripheral neurons and Schwann cells, and provide a major advancement toward developing effective therapies for peripheral

  17. Adjusted functional boxplots for spatio-temporal data visualization and outlier detection

    KAUST Repository

    Sun, Ying

    2011-10-24

    This article proposes a simulation-based method to adjust functional boxplots for correlations when visualizing functional and spatio-temporal data, as well as detecting outliers. We start by investigating the relationship between the spatio-temporal dependence and the 1.5 times the 50% central region empirical outlier detection rule. Then, we propose to simulate observations without outliers on the basis of a robust estimator of the covariance function of the data. We select the constant factor in the functional boxplot to control the probability of correctly detecting no outliers. Finally, we apply the selected factor to the functional boxplot of the original data. As applications, the factor selection procedure and the adjusted functional boxplots are demonstrated on sea surface temperatures, spatio-temporal precipitation and general circulation model (GCM) data. The outlier detection performance is also compared before and after the factor adjustment. © 2011 John Wiley & Sons, Ltd.

  18. Optimization of Visual Information Presentation for Visual Prosthesis

    Directory of Open Access Journals (Sweden)

    Fei Guo

    2018-01-01

    Full Text Available Visual prosthesis applying electrical stimulation to restore visual function for the blind has promising prospects. However, due to the low resolution, limited visual field, and the low dynamic range of the visual perception, huge loss of information occurred when presenting daily scenes. The ability of object recognition in real-life scenarios is severely restricted for prosthetic users. To overcome the limitations, optimizing the visual information in the simulated prosthetic vision has been the focus of research. This paper proposes two image processing strategies based on a salient object detection technique. The two processing strategies enable the prosthetic implants to focus on the object of interest and suppress the background clutter. Psychophysical experiments show that techniques such as foreground zooming with background clutter removal and foreground edge detection with background reduction have positive impacts on the task of object recognition in simulated prosthetic vision. By using edge detection and zooming technique, the two processing strategies significantly improve the recognition accuracy of objects. We can conclude that the visual prosthesis using our proposed strategy can assist the blind to improve their ability to recognize objects. The results will provide effective solutions for the further development of visual prosthesis.

  19. Optimization of Visual Information Presentation for Visual Prosthesis

    Science.gov (United States)

    Gao, Yong

    2018-01-01

    Visual prosthesis applying electrical stimulation to restore visual function for the blind has promising prospects. However, due to the low resolution, limited visual field, and the low dynamic range of the visual perception, huge loss of information occurred when presenting daily scenes. The ability of object recognition in real-life scenarios is severely restricted for prosthetic users. To overcome the limitations, optimizing the visual information in the simulated prosthetic vision has been the focus of research. This paper proposes two image processing strategies based on a salient object detection technique. The two processing strategies enable the prosthetic implants to focus on the object of interest and suppress the background clutter. Psychophysical experiments show that techniques such as foreground zooming with background clutter removal and foreground edge detection with background reduction have positive impacts on the task of object recognition in simulated prosthetic vision. By using edge detection and zooming technique, the two processing strategies significantly improve the recognition accuracy of objects. We can conclude that the visual prosthesis using our proposed strategy can assist the blind to improve their ability to recognize objects. The results will provide effective solutions for the further development of visual prosthesis. PMID:29731769

  20. Effects of Audio-Visual Integration on the Detection of Masked Speech and Non-Speech Sounds

    Science.gov (United States)

    Eramudugolla, Ranmalee; Henderson, Rachel; Mattingley, Jason B.

    2011-01-01

    Integration of simultaneous auditory and visual information about an event can enhance our ability to detect that event. This is particularly evident in the perception of speech, where the articulatory gestures of the speaker's lips and face can significantly improve the listener's detection and identification of the message, especially when that…

  1. Visual detection of glial cell line-derived neurotrophic factor based on a molecular translator and isothermal strand-displacement polymerization reaction.

    Science.gov (United States)

    Zhang, Li-Yong; Xing, Tao; Du, Li-Xin; Li, Qing-Min; Liu, Wei-Dong; Wang, Ji-Yue; Cai, Jing

    2015-01-01

    Glial cell line-derived neurotrophic factor (GDNF) is a small protein that potently promotes the survival of many types of neurons. Detection of GDNF is vital to monitoring the survival of sympathetic and sensory neurons. However, the specific method for GDNF detection is also un-discovered. The purpose of this study is to explore the method for protein detection of GDNF. A novel visual detection method based on a molecular translator and isothermal strand-displacement polymerization reaction (ISDPR) has been proposed for the detection of GDNF. In this study, a molecular translator was employed to convert the input protein to output deoxyribonucleic acid signal, which was further amplified by ISDPR. The product of ISDPR was detected by a lateral flow biosensor within 30 minutes. This novel visual detection method based on a molecular translator and ISDPR has very high sensitivity and selectivity, with a dynamic response ranging from 1 pg/mL to 10 ng/mL, and the detection limit was 1 pg/mL of GDNF. This novel visual detection method exhibits high sensitivity and selectivity, which is very simple and universal for GDNF detection to help disease therapy in clinical practice.

  2. Frontal Theta Activity Supports Detecting Mismatched Information in Visual Working Memory.

    Science.gov (United States)

    Liang, Tengfei; Hu, Zhonghua; Liu, Qiang

    2017-01-01

    During the comparison stage of visual working memory (VWM) processing, detecting the mismatch between the external sensory input and internal representations is a crucial cognitive ability for human, but the neural mechanism behind it remains largely unclear. The present study investigated the role of frontal theta power in detecting the mismatched information in VWM in a delayed matching task. A control task required to compare two simultaneously presented visual figures was also designed as a contrast to exclude the possibility that frontal theta activity just reflecting the non-memory-related behavioral conflicts. To better characterize the control mechanisms shaped by the frontal theta oscillation in human VWM, colored shapes were adopted as materials while both the task-relevant shape feature and task-irrelevant color feature could be mismatched. We found that the response times of participants were significantly delayed under the relevant- and irrelevant-mismatch conditions in both tasks and the conjunction-mismatch condition in delayed matching task. While our EEG data showed that increased frontal theta power was only observed under the relevant- and conjunction-mismatch conditions in the delayed matching task, but not the control task. These findings suggest that the frontal distributed theta activity observed here reflects the detection of mismatched information during the comparison stage of VWM, rather than the response-related conflicts. Furthermore, it is consistent with the proposal that theta-band oscillation can act as a control mechanism in working memory function so that the target-mismatched information in VWM could be successfully tracked. We also propose a possible processing structure to explain the neural dynamics underlying the mismatch detection process in VWM.

  3. Frontal Theta Activity Supports Detecting Mismatched Information in Visual Working Memory

    Directory of Open Access Journals (Sweden)

    Tengfei Liang

    2017-10-01

    Full Text Available During the comparison stage of visual working memory (VWM processing, detecting the mismatch between the external sensory input and internal representations is a crucial cognitive ability for human, but the neural mechanism behind it remains largely unclear. The present study investigated the role of frontal theta power in detecting the mismatched information in VWM in a delayed matching task. A control task required to compare two simultaneously presented visual figures was also designed as a contrast to exclude the possibility that frontal theta activity just reflecting the non-memory-related behavioral conflicts. To better characterize the control mechanisms shaped by the frontal theta oscillation in human VWM, colored shapes were adopted as materials while both the task-relevant shape feature and task-irrelevant color feature could be mismatched. We found that the response times of participants were significantly delayed under the relevant- and irrelevant-mismatch conditions in both tasks and the conjunction-mismatch condition in delayed matching task. While our EEG data showed that increased frontal theta power was only observed under the relevant- and conjunction-mismatch conditions in the delayed matching task, but not the control task. These findings suggest that the frontal distributed theta activity observed here reflects the detection of mismatched information during the comparison stage of VWM, rather than the response-related conflicts. Furthermore, it is consistent with the proposal that theta-band oscillation can act as a control mechanism in working memory function so that the target-mismatched information in VWM could be successfully tracked. We also propose a possible processing structure to explain the neural dynamics underlying the mismatch detection process in VWM.

  4. Creation of an Accurate Algorithm to Detect Snellen Best Documented Visual Acuity from Ophthalmology Electronic Health Record Notes.

    Science.gov (United States)

    Mbagwu, Michael; French, Dustin D; Gill, Manjot; Mitchell, Christopher; Jackson, Kathryn; Kho, Abel; Bryar, Paul J

    2016-05-04

    Visual acuity is the primary measure used in ophthalmology to determine how well a patient can see. Visual acuity for a single eye may be recorded in multiple ways for a single patient visit (eg, Snellen vs. Jäger units vs. font print size), and be recorded for either distance or near vision. Capturing the best documented visual acuity (BDVA) of each eye in an individual patient visit is an important step for making electronic ophthalmology clinical notes useful in research. Currently, there is limited methodology for capturing BDVA in an efficient and accurate manner from electronic health record (EHR) notes. We developed an algorithm to detect BDVA for right and left eyes from defined fields within electronic ophthalmology clinical notes. We designed an algorithm to detect the BDVA from defined fields within 295,218 ophthalmology clinical notes with visual acuity data present. About 5668 unique responses were identified and an algorithm was developed to map all of the unique responses to a structured list of Snellen visual acuities. Visual acuity was captured from a total of 295,218 ophthalmology clinical notes during the study dates. The algorithm identified all visual acuities in the defined visual acuity section for each eye and returned a single BDVA for each eye. A clinician chart review of 100 random patient notes showed a 99% accuracy detecting BDVA from these records and 1% observed error. Our algorithm successfully captures best documented Snellen distance visual acuity from ophthalmology clinical notes and transforms a variety of inputs into a structured Snellen equivalent list. Our work, to the best of our knowledge, represents the first attempt at capturing visual acuity accurately from large numbers of electronic ophthalmology notes. Use of this algorithm can benefit research groups interested in assessing visual acuity for patient centered outcome. All codes used for this study are currently available, and will be made available online at https://phekb.org.

  5. Balance rehabilitation: promoting the role of virtual reality in patients with diabetic peripheral neuropathy.

    Science.gov (United States)

    Grewal, Gurtej S; Sayeed, Rashad; Schwenk, Michael; Bharara, Manish; Menzies, Robert; Talal, Talal K; Armstrong, David G; Najafi, Bijan

    2013-01-01

    Individuals with diabetic peripheral neuropathy frequently experience concomitant impaired proprioception and postural instability. Conventional exercise training has been demonstrated to be effective in improving balance but does not incorporate visual feedback targeting joint perception, which is an integral mechanism that helps compensate for impaired proprioception in diabetic peripheral neuropathy. This prospective cohort study recruited 29 participants (mean ± SD: age, 57 ± 10 years; body mass index [calculated as weight in kilograms divided by height in meters squared], 26.9 ± 3.1). Participants satisfying the inclusion criteria performed predefined ankle exercises through reaching tasks, with visual feedback from the ankle joint projected on a screen. Ankle motion in the mediolateral and anteroposterior directions was captured using wearable sensors attached to the participant's shank. Improvements in postural stability were quantified by measuring center of mass sway area and the reciprocal compensatory index before and after training using validated body-worn sensor technology. Findings revealed a significant reduction in center of mass sway after training (mean, 22%; P = .02). A higher postural stability deficit (high body sway) at baseline was associated with higher training gains in postural balance (reduction in center of mass sway) (r = -0.52, P virtual reality technology. The method included wearable sensors and an interactive user interface for real-time visual feedback based on ankle joint motion, similar to a video gaming environment, for compensating impaired joint proprioception. These findings support that visual feedback generated from the ankle joint coupled with motor learning may be effective in improving postural stability in patients with diabetic peripheral neuropathy.

  6. An Integrated Theory of Attention and Decision Making in Visual Signal Detection

    Science.gov (United States)

    Smith, Philip L.; Ratcliff, Roger

    2009-01-01

    The simplest attentional task, detecting a cued stimulus in an otherwise empty visual field, produces complex patterns of performance. Attentional cues interact with backward masks and with spatial uncertainty, and there is a dissociation in the effects of these variables on accuracy and on response time. A computational theory of performance in…

  7. Colour and luminance contrasts predict the human detection of natural stimuli in complex visual environments.

    Science.gov (United States)

    White, Thomas E; Rojas, Bibiana; Mappes, Johanna; Rautiala, Petri; Kemp, Darrell J

    2017-09-01

    Much of what we know about human colour perception has come from psychophysical studies conducted in tightly-controlled laboratory settings. An enduring challenge, however, lies in extrapolating this knowledge to the noisy conditions that characterize our actual visual experience. Here we combine statistical models of visual perception with empirical data to explore how chromatic (hue/saturation) and achromatic (luminant) information underpins the detection and classification of stimuli in a complex forest environment. The data best support a simple linear model of stimulus detection as an additive function of both luminance and saturation contrast. The strength of each predictor is modest yet consistent across gross variation in viewing conditions, which accords with expectation based upon general primate psychophysics. Our findings implicate simple visual cues in the guidance of perception amidst natural noise, and highlight the potential for informing human vision via a fusion between psychophysical modelling and real-world behaviour. © 2017 The Author(s).

  8. No apparent influence of psychometrically-defined schizotypy on orientation-dependent contextual modulation of visual contrast detection

    Directory of Open Access Journals (Sweden)

    Damien J. Mannion

    2017-01-01

    Full Text Available We investigated the relationship between psychometrically-defined schizotypy and the ability to detect a visual target pattern. Target detection is typically impaired by a surrounding pattern (context with an orientation that is parallel to the target, relative to a surrounding pattern with an orientation that is orthogonal to the target (orientation-dependent contextual modulation. Based on reports that this effect is reduced in those with schizophrenia, we hypothesised that there would be a negative relationship between the relative score on psychometrically-defined schizotypy and the relative effect of orientation-dependent contextual modulation. We measured visual contrast detection thresholds and scores on the Oxford-Liverpool Inventory of Feelings and Experiences (O-LIFE from a non-clinical sample (N = 100. Contrary to our hypothesis, we find an absence of a monotonic relationship between the relative magnitude of orientation-dependent contextual modulation of visual contrast detection and the relative score on any of the subscales of the O-LIFE. The apparent difference of this result with previous reports on those with schizophrenia suggests that orientation-dependent contextual modulation may be an informative condition in which schizophrenia and psychometrically-defined schizotypy are dissociated. However, further research is also required to clarify the strength of orientation-dependent contextual modulation in those with schizophrenia.

  9. Visual working memory and threat monitoring: Spider fearfuls show disorder-specific change detection

    NARCIS (Netherlands)

    Reinecke, A.; Becker, E.S.; Rinck, M.

    2010-01-01

    Previous studies of biased information processing in anxiety addressed biases of attention and memory, but little is known about the processes taking place between them: visual working memory (VWM) and monitoring of threat. We investigated these processes with a change detection paradigm. In

  10. Colour Terms Affect Detection of Colour and Colour-Associated Objects Suppressed from Visual Awareness

    Science.gov (United States)

    Forder, Lewis; Taylor, Olivia; Mankin, Helen; Scott, Ryan B.; Franklin, Anna

    2016-01-01

    The idea that language can affect how we see the world continues to create controversy. A potentially important study in this field has shown that when an object is suppressed from visual awareness using continuous flash suppression (a form of binocular rivalry), detection of the object is differently affected by a preceding word prime depending on whether the prime matches or does not match the object. This may suggest that language can affect early stages of vision. We replicated this paradigm and further investigated whether colour terms likewise influence the detection of colours or colour-associated object images suppressed from visual awareness by continuous flash suppression. This method presents rapidly changing visual noise to one eye while the target stimulus is presented to the other. It has been shown to delay conscious perception of a target for up to several minutes. In Experiment 1 we presented greyscale photos of objects. They were either preceded by a congruent object label, an incongruent label, or white noise. Detection sensitivity (d’) and hit rates were significantly poorer for suppressed objects preceded by an incongruent label compared to a congruent label or noise. In Experiment 2, targets were coloured discs preceded by a colour term. Detection sensitivity was significantly worse for suppressed colour patches preceded by an incongruent colour term as compared to a congruent term or white noise. In Experiment 3 targets were suppressed greyscale object images preceded by an auditory presentation of a colour term. On congruent trials the colour term matched the object’s stereotypical colour and on incongruent trials the colour term mismatched. Detection sensitivity was significantly poorer on incongruent trials than congruent trials. Overall, these findings suggest that colour terms affect awareness of coloured stimuli and colour- associated objects, and provide new evidence for language-perception interaction in the brain. PMID:27023274

  11. Colour Terms Affect Detection of Colour and Colour-Associated Objects Suppressed from Visual Awareness.

    Science.gov (United States)

    Forder, Lewis; Taylor, Olivia; Mankin, Helen; Scott, Ryan B; Franklin, Anna

    2016-01-01

    The idea that language can affect how we see the world continues to create controversy. A potentially important study in this field has shown that when an object is suppressed from visual awareness using continuous flash suppression (a form of binocular rivalry), detection of the object is differently affected by a preceding word prime depending on whether the prime matches or does not match the object. This may suggest that language can affect early stages of vision. We replicated this paradigm and further investigated whether colour terms likewise influence the detection of colours or colour-associated object images suppressed from visual awareness by continuous flash suppression. This method presents rapidly changing visual noise to one eye while the target stimulus is presented to the other. It has been shown to delay conscious perception of a target for up to several minutes. In Experiment 1 we presented greyscale photos of objects. They were either preceded by a congruent object label, an incongruent label, or white noise. Detection sensitivity (d') and hit rates were significantly poorer for suppressed objects preceded by an incongruent label compared to a congruent label or noise. In Experiment 2, targets were coloured discs preceded by a colour term. Detection sensitivity was significantly worse for suppressed colour patches preceded by an incongruent colour term as compared to a congruent term or white noise. In Experiment 3 targets were suppressed greyscale object images preceded by an auditory presentation of a colour term. On congruent trials the colour term matched the object's stereotypical colour and on incongruent trials the colour term mismatched. Detection sensitivity was significantly poorer on incongruent trials than congruent trials. Overall, these findings suggest that colour terms affect awareness of coloured stimuli and colour- associated objects, and provide new evidence for language-perception interaction in the brain.

  12. Colour Terms Affect Detection of Colour and Colour-Associated Objects Suppressed from Visual Awareness.

    Directory of Open Access Journals (Sweden)

    Lewis Forder

    Full Text Available The idea that language can affect how we see the world continues to create controversy. A potentially important study in this field has shown that when an object is suppressed from visual awareness using continuous flash suppression (a form of binocular rivalry, detection of the object is differently affected by a preceding word prime depending on whether the prime matches or does not match the object. This may suggest that language can affect early stages of vision. We replicated this paradigm and further investigated whether colour terms likewise influence the detection of colours or colour-associated object images suppressed from visual awareness by continuous flash suppression. This method presents rapidly changing visual noise to one eye while the target stimulus is presented to the other. It has been shown to delay conscious perception of a target for up to several minutes. In Experiment 1 we presented greyscale photos of objects. They were either preceded by a congruent object label, an incongruent label, or white noise. Detection sensitivity (d' and hit rates were significantly poorer for suppressed objects preceded by an incongruent label compared to a congruent label or noise. In Experiment 2, targets were coloured discs preceded by a colour term. Detection sensitivity was significantly worse for suppressed colour patches preceded by an incongruent colour term as compared to a congruent term or white noise. In Experiment 3 targets were suppressed greyscale object images preceded by an auditory presentation of a colour term. On congruent trials the colour term matched the object's stereotypical colour and on incongruent trials the colour term mismatched. Detection sensitivity was significantly poorer on incongruent trials than congruent trials. Overall, these findings suggest that colour terms affect awareness of coloured stimuli and colour- associated objects, and provide new evidence for language-perception interaction in the brain.

  13. Performance of an iPad Application to Detect Moderate and Advanced Visual Field Loss in Nepal.

    Science.gov (United States)

    Johnson, Chris A; Thapa, Suman; George Kong, Yu Xiang; Robin, Alan L

    2017-10-01

    To evaluate the accuracy and efficiency of Visual Fields Easy (VFE), a free iPad app, for performing suprathreshold perimetric screening. Prospective, cross-sectional validation study. We performed screening visual fields using a calibrated iPad 2 with the VFE application on 206 subjects (411 eyes): 210 normal (NL), 183 glaucoma (GL), and 18 diabetic retinopathy (DR) at Tilganga Institute of Ophthalmology, Kathmandu, Nepal. We correlated the results with a Humphrey Field Analyzer using 24-2 SITA Standard tests on 373 of these eyes (198 NL, 160 GL, 15 DR). The number of missed locations on the VFE correlated with mean deviation (MD, r = 0.79), pattern standard deviation (PSD, r = 0.60), and number of locations that were worse than the 95% confidence limits for total deviation (r = 0.51) and pattern deviation (r = 0.68) using SITA Standard. iPad suprathreshold perimetry was able to detect most visual field deficits with moderate (MD of -6 to -12 dB) and advanced (MD worse than -12 dB) loss, but had greater difficulty in detecting early (MD better than -6 dB) loss, primarily owing to an elevated false-positive response rate. The average time to perform the Visual Fields Easy test was 3 minutes, 18 seconds (standard deviation = 16.88 seconds). The Visual Fields Easy test procedure is a portable, fast, effective procedure for detecting moderate and advanced visual field loss. Improvements are currently underway to monitor eye and head tracking during testing, reduce testing time, improve performance, and eliminate the need to touch the video screen surface. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Detection of visual events along the apparent motion trace in patients with paranoid schizophrenia.

    Science.gov (United States)

    Sanders, Lia Lira Olivier; Muckli, Lars; de Millas, Walter; Lautenschlager, Marion; Heinz, Andreas; Kathmann, Norbert; Sterzer, Philipp

    2012-07-30

    Dysfunctional prediction in sensory processing has been suggested as a possible causal mechanism in the development of delusions in patients with schizophrenia. Previous studies in healthy subjects have shown that while the perception of apparent motion can mask visual events along the illusory motion trace, such motion masking is reduced when events are spatio-temporally compatible with the illusion, and, therefore, predictable. Here we tested the hypothesis that this specific detection advantage for predictable target stimuli on the apparent motion trace is reduced in patients with paranoid schizophrenia. Our data show that, although target detection along the illusory motion trace is generally impaired, both patients and healthy control participants detect predictable targets more often than unpredictable targets. Patients had a stronger motion masking effect when compared to controls. However, patients showed the same advantage in the detection of predictable targets as healthy control subjects. Our findings reveal stronger motion masking but intact prediction of visual events along the apparent motion trace in patients with paranoid schizophrenia and suggest that the sensory prediction mechanism underlying apparent motion is not impaired in paranoid schizophrenia. Copyright © 2012. Published by Elsevier Ireland Ltd.

  15. Visual perceptual load reduces auditory detection in typically developing individuals but not in individuals with autism spectrum disorders.

    Science.gov (United States)

    Tillmann, Julian; Swettenham, John

    2017-02-01

    Previous studies examining selective attention in individuals with autism spectrum disorder (ASD) have yielded conflicting results, some suggesting superior focused attention (e.g., on visual search tasks), others demonstrating greater distractibility. This pattern could be accounted for by the proposal (derived by applying the Load theory of attention, e.g., Lavie, 2005) that ASD is characterized by an increased perceptual capacity (Remington, Swettenham, Campbell, & Coleman, 2009). Recent studies in the visual domain support this proposal. Here we hypothesize that ASD involves an enhanced perceptual capacity that also operates across sensory modalities, and test this prediction, for the first time using a signal detection paradigm. Seventeen neurotypical (NT) and 15 ASD adolescents performed a visual search task under varying levels of visual perceptual load while simultaneously detecting presence/absence of an auditory tone embedded in noise. Detection sensitivity (d') for the auditory stimulus was similarly high for both groups in the low visual perceptual load condition (e.g., 2 items: p = .391, d = 0.31, 95% confidence interval [CI] [-0.39, 1.00]). However, at a higher level of visual load, auditory d' reduced for the NT group but not the ASD group, leading to a group difference (p = .002, d = 1.2, 95% CI [0.44, 1.96]). As predicted, when visual perceptual load was highest, both groups then showed a similarly low auditory d' (p = .9, d = 0.05, 95% CI [-0.65, 0.74]). These findings demonstrate that increased perceptual capacity in ASD operates across modalities. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  16. Comparison of Diagnostic Accuracy between Octopus 900 and Goldmann Kinetic Visual Fields

    Directory of Open Access Journals (Sweden)

    Fiona J. Rowe

    2014-01-01

    Full Text Available Purpose. To determine diagnostic accuracy of kinetic visual field assessment by Octopus 900 perimetry compared with Goldmann perimetry. Methods. Prospective cross section evaluation of 40 control subjects with full visual fields and 50 patients with known visual field loss. Comparison of test duration and area measurement of isopters for Octopus 3, 5, and 10°/sec stimulus speeds. Comparison of test duration and type of visual field classification for Octopus versus Goldmann perimetry. Results were independently graded for presence/absence of field defect and for type and location of defect. Statistical evaluation comprised of ANOVA and paired t test for evaluation of parametric data with Bonferroni adjustment. Bland Altman and Kappa tests were used for measurement of agreement between data. Results. Octopus 5°/sec perimetry had comparable test duration to Goldmann perimetry. Octopus perimetry reliably detected type and location of visual field loss with visual fields matched to Goldmann results in 88.8% of results (K=0.775. Conclusions. Kinetic perimetry requires individual tailoring to ensure accuracy. Octopus perimetry was reproducible for presence/absence of visual field defect. Our screening protocol when using Octopus perimetry is 5°/sec for determining boundaries of peripheral isopters and 3°/sec for blind spot mapping with further evaluation of area of field loss for defect depth and size.

  17. Control of peripheral units by satellite computer

    International Nuclear Information System (INIS)

    Tran, K.T.

    1974-01-01

    A computer system was developed allowing the control of nuclear physics experiments, and use of the results by means of graphical and conversational assemblies. This system which is made of two computers, one IBM-370/135 and one Telemecanique Electrique T1600, controls the conventional IBM peripherals and also the special ones made in the laboratory, such as data acquisition display and graphics units. The visual display is implemented by a scanning-type television, equipped with a light-pen. These units in themselves are universal, but their specifications were established to meet the requirements of nuclear physics experiments. The input-output channels of the two computers have been connected together by an interface, designed and implemented in the Laboratory. This interface allows the exchange of control signals and data (the data are changed from bytes into word and vice-versa). The T1600 controls the peripherals mentionned above according to the commands of the IBM370. Hence the T1600 has here the part of a satellite computer which allows conversation with the main computer and also insures the control of its special peripheral units [fr

  18. Peripheral facial weakness (Bell's palsy).

    Science.gov (United States)

    Basić-Kes, Vanja; Dobrota, Vesna Dermanović; Cesarik, Marijan; Matovina, Lucija Zadro; Madzar, Zrinko; Zavoreo, Iris; Demarin, Vida

    2013-06-01

    Peripheral facial weakness is a facial nerve damage that results in muscle weakness on one side of the face. It may be idiopathic (Bell's palsy) or may have a detectable cause. Almost 80% of peripheral facial weakness cases are primary and the rest of them are secondary. The most frequent causes of secondary peripheral facial weakness are systemic viral infections, trauma, surgery, diabetes, local infections, tumor, immune disorders, drugs, degenerative diseases of the central nervous system, etc. The diagnosis relies upon the presence of typical signs and symptoms, blood chemistry tests, cerebrospinal fluid investigations, nerve conduction studies and neuroimaging methods (cerebral MRI, x-ray of the skull and mastoid). Treatment of secondary peripheral facial weakness is based on therapy for the underlying disorder, unlike the treatment of Bell's palsy that is controversial due to the lack of large, randomized, controlled, prospective studies. There are some indications that steroids or antiviral agents are beneficial but there are also studies that show no beneficial effect. Additional treatments include eye protection, physiotherapy, acupuncture, botulinum toxin, or surgery. Bell's palsy has a benign prognosis with complete recovery in about 80% of patients, 15% experience some mode of permanent nerve damage and severe consequences remain in 5% of patients.

  19. Visual Adaptations for Mate Detection in the Male Carpenter Bee Xylocopa tenuiscapa.

    Directory of Open Access Journals (Sweden)

    Hema Somanathan

    Full Text Available Sexual dimorphism in eye structure is attributed to sexual selection in animals that employ vision for locating mates. In many male insects, large eyes and eye regions of higher acuity are believed to facilitate the location of females. Here, we compare various features of male and female eyes in three sympatric carpenter bee species, which include two diurnal species (Xylocopa tenuiscapa and X. leucothorax as well as a nocturnal species (X. tranquebarica. In X. tenuiscapa, males have larger eyes than females, while in the nocturnal X. tranquebarica, males have slightly smaller eyes and in X. leucothorax, the eyes are of similar size in both sexes. X. tenuiscapa males detect females by perching near nest sites (resource defence or along fly-ways and other open areas with good visibility. Males of the other two species search for females by patrolling. We postulate that the larger eyes of male X. tenuiscapa are beneficial to their mode of mate detection since perching males may benefit from a larger visual area of high resolution detecting moving stimuli across the sky, and which may be germane to the more social and gregarious nesting behaviour of this species, compared to the other solitary bees. We tested the performance of the eyes of male X. tenuiscapa behaviourally and find that a perching male can detect a flying female at a distance of 20 m, which darkens the visual field of a single ommatidium by just 2%. This, together with the bee's high spatial resolution permits detection of moving stimuli at least as well or even better than achieved by honey bee drones.

  20. The influence of artificial scotomas on eye movements during visual search

    NARCIS (Netherlands)

    Cornelissen, FW; Bruin, KJ; Kooijman, AC

    Purpose. Fixation durations are normally adapted to the difficulty of the foveal analysis task. We examine to what extent artificial central and peripheral visual field defects interfere with this adaptation process. Methods. Subjects performed a visual search task while their eye movements were

  1. Substantial adverse association of visual and vascular comorbidities on visual disability in multiple sclerosis.

    Science.gov (United States)

    Marrie, Ruth Ann; Cutter, Gary; Tyry, Tuula

    2011-12-01

    Visual comorbidities are common in multiple sclerosis (MS) but the impact of visual comorbidities on visual disability is unknown. We assessed the impact of visual and vascular comorbidities on severity of visual disability in MS. In 2006, we queried participants of the North American Research Committee on Multiple Sclerosis (NARCOMS) about cataracts, glaucoma, uveitis, hypertension, hypercholesterolemia, heart disease, diabetes and peripheral vascular disease. We assessed visual disability using the Vision subscale of Performance Scales. Using Cox regression, we investigated whether visual or vascular comorbidities affected the time between MS symptom onset and the development of mild, moderate and severe visual disability. Of 8983 respondents, 1415 (15.9%) reported a visual comorbidity while 4745 (52.8%) reported a vascular comorbidity. The median (interquartile range) visual score was 1 (0-2). In a multivariable Cox model the risk of mild visual disability was higher among participants with vascular (hazard ratio [HR] 1.45; 95% confidence interval [CI]: 1.39-1.51) and visual comorbidities (HR 1.47; 95% CI: 1.37-1.59). Vascular and visual comorbidities were similarly associated with increased risks of moderate and severe visual disability. Visual and vascular comorbidities are associated with progression of visual disability in MS. Clinicians hearing reports of worsening visual symptoms in MS patients should consider visual comorbidities as contributing factors. Further study of these issues using objective, systematic neuro-ophthalmologic evaluations is warranted.

  2. Establishment and Application of a Visual DNA Microarray for the Detection of Food-borne Pathogens.

    Science.gov (United States)

    Li, Yongjin

    2016-01-01

    The accurate detection and identification of food-borne pathogenic microorganisms is critical for food safety nowadays. In the present work, a visual DNA microarray was established and applied to detect pathogens commonly found in food, including Salmonella enterica, Shigella flexneri, E. coli O157:H7 and Listeria monocytogenes in food samples. Multiplex PCR (mPCR) was employed to simultaneously amplify specific gene fragments, fimY for Salmonella, ipaH for Shigella, iap for L. monocytogenes and ECs2841 for E. coli O157:H7, respectively. Biotinylated PCR amplicons annealed to the microarray probes were then reacted with a streptavidin-alkaline phosphatase conjugate and nitro blue tetrazolium/5-bromo-4-chloro-3'-indolylphosphate, p-toluidine salt (NBT/BCIP); the positive results were easily visualized as blue dots formatted on the microarray surface. The performance of a DNA microarray was tested against 14 representative collection strains and mock-contamination food samples. The combination of mPCR and a visual micro-plate chip specifically and sensitively detected Salmonella enterica, Shigella flexneri, E. coli O157:H7 and Listeria monocytogenes in standard strains and food matrices with a sensitivity of ∼10(2) CFU/mL of bacterial culture. Thus, the developed method is advantageous because of its high throughput, cost-effectiveness and ease of use.

  3. Assistive peripheral phosphene arrays deliver advantages in obstacle avoidance in simulated end-stage retinitis pigmentosa: a virtual-reality study

    Science.gov (United States)

    Zapf, Marc Patrick H.; Boon, Mei-Ying; Lovell, Nigel H.; Suaning, Gregg J.

    2016-04-01

    Objective. The prospective efficacy of peripheral retinal prostheses for guiding orientation and mobility in the absence of residual vision, as compared to an implant for the central visual field (VF), was evaluated using simulated prosthetic vision (SPV). Approach. Sighted volunteers wearing a head-mounted display performed an obstacle circumvention task under SPV. Mobility and orientation performance with three layouts of prosthetic vision were compared: peripheral prosthetic vision of higher visual acuity (VA) but limited VF, of wider VF but limited VA, as well as centrally restricted prosthetic vision. Learning curves using these layouts were compared fitting an exponential model to the mobility and orientation measures. Main results. Using peripheral layouts, performance was superior to the central layout. Walking speed with both higher-acuity and wider-angle layouts was 5.6% higher, and mobility errors reduced by 46.4% and 48.6%, respectively, as compared to the central layout. The wider-angle layout yielded the least number of collisions, 63% less than the higher-acuity and 73% less than the central layout. Using peripheral layouts, the number of visual-scanning related head movements was 54.3% (higher-acuity) and 60.7% (wider-angle) lower, as compared to the central layout, and the ratio of time standing versus time walking was 51.9% and 61.5% lower, respectively. Learning curves did not differ between layouts, except for time standing versus time walking, where both peripheral layouts achieved significantly lower asymptotic values compared to the central layout. Significance. Beyond complementing residual vision for an improved performance, peripheral prosthetic vision can effectively guide mobility in the later stages of retinitis pigmentosa (RP) without residual vision. Further, the temporal dynamics of learning peripheral and central prosthetic vision are similar. Therefore, development of a peripheral retinal prosthesis and early implantation to

  4. Effect of visual field locus and oscillation frequencies on posture control in an ecological environment.

    Science.gov (United States)

    Piponnier, Jean-Claude; Hanssens, Jean-Marie; Faubert, Jocelyn

    2009-01-14

    To examine the respective roles of central and peripheral vision in the control of posture, body sway amplitude (BSA) and postural perturbations (given by velocity root mean square or vRMS) were calculated in a group of 19 healthy young adults. The stimulus was a 3D tunnel, either static or moving sinusoidally in the anterior-posterior direction. There were nine visual field conditions: four central conditions (4, 7, 15, and 30 degrees); four peripheral conditions (central occlusions of 4, 7, 15, and 30 degrees); and a full visual field condition (FF). The virtual tunnel respected all the aspects of a real physical tunnel (i.e., stereoscopy and size increase with proximity). The results show that, under static conditions, central and peripheral visual fields appear to have equal importance for the control of stance. In the presence of an optic flow, peripheral vision plays a crucial role in the control of stance, since it is responsible for a compensatory sway, whereas central vision has an accessory role that seems to be related to spatial orientation.

  5. Visual spatial attention enhances the amplitude of positive and negative fMRI responses to visual stimulation in an eccentricity-dependent manner

    Science.gov (United States)

    Bressler, David W.; Fortenbaugh, Francesca C.; Robertson, Lynn C.; Silver, Michael A.

    2013-01-01

    Endogenous visual spatial attention improves perception and enhances neural responses to visual stimuli at attended locations. Although many aspects of visual processing differ significantly between central and peripheral vision, little is known regarding the neural substrates of the eccentricity dependence of spatial attention effects. We measured amplitudes of positive and negative fMRI responses to visual stimuli as a function of eccentricity in a large number of topographically-organized cortical areas. Responses to each stimulus were obtained when the stimulus was attended and when spatial attention was directed to a stimulus in the opposite visual hemifield. Attending to the stimulus increased both positive and negative response amplitudes in all cortical areas we studied: V1, V2, V3, hV4, VO1, LO1, LO2, V3A/B, IPS0, TO1, and TO2. However, the eccentricity dependence of these effects differed considerably across cortical areas. In early visual, ventral, and lateral occipital cortex, attentional enhancement of positive responses was greater for central compared to peripheral eccentricities. The opposite pattern was observed in dorsal stream areas IPS0 and putative MT homolog TO1, where attentional enhancement of positive responses was greater in the periphery. Both the magnitude and the eccentricity dependence of attentional modulation of negative fMRI responses closely mirrored that of positive responses across cortical areas. PMID:23562388

  6. Molecular detection of peripheral blood breast cancer mRNA transcripts as a surrogate biomarker for circulating tumor cells.

    Directory of Open Access Journals (Sweden)

    Adriana Lasa

    Full Text Available Circulating tumor cells (CTCs are becoming a scientifically recognized indicator of primary tumors and/or metastasis. These cells can now be accurately detected and characterized as the result of technological advances. We analyzed the presence of CTCs in the peripheral blood of patients with metastatic breast cancer by real-time reverse-transcription PCR (RT-qPCR using a panel of selected genes. The analysis of a single marker, without an EpCAM based enrichment approach, allowed the positive identification of 35% of the metastatic breast cancer patients. The analysis of five genes (SCGB2, TFF1, TFF3, Muc1, KRT20 performed in all the samples increased the detection to 61%. We describe a sensitive, reproducible and easy to implement approach to characterize CTC in patients with metastasic breast cancer.

  7. Molecular assays for the detection of prostate tumor derived nucleic acids in peripheral blood

    Directory of Open Access Journals (Sweden)

    Kinnunen Martin

    2010-07-01

    Full Text Available Abstract Background Prostate cancer is the second leading cause of cancer mortality in American men. Although serum PSA testing is widely used for early detection, more specific prognostic tests are needed to guide treatment decisions. Recently, the enumeration of circulating prostate epithelial cells has been shown to correlate with disease recurrence and metastasis following definitive treatment. The purpose of our study was to investigate an immunomagnetic fractionation procedure to enrich circulating prostate tumor cells (CTCs from peripheral blood specimens, and to apply amplified molecular assays for the detection of prostate-specific markers (PSA, PCA3 and TMPRSS2:ERG gene fusion mRNAs. Results As few as five prostate cancer cells were detected per 5 mL of whole blood in model system experiments using anti-EpCAM magnetic particles alone or in combination with anti-PSMA magnetic particles. In our experiments, anti-EpCAM magnetic particles alone exhibited equivalent or better analytical performance with patient samples compared to a combination of anti-EpCAM + anti-PSMA magnetic particles. Up to 39% of men with advanced prostate cancer tested positive with one or more of the molecular assays tested, whereas control samples from men with benign prostate hyperplasia gave consistently negative results as expected. Interestingly, for the vast majority of men who tested positive for PSA mRNA following CTC enrichment, their matched plasma samples also tested positive, although CTC enrichment gave higher overall mRNA copy numbers. Conclusion CTCs were successfully enriched and detected in men with advanced prostate cancer using an immunomagnetic enrichment procedure coupled with amplified molecular assays for PSA, PCA3, and TMPRSS2:ERG gene fusion mRNAs. Our results indicate that men who test positive following CTC enrichment also exhibit higher detectable levels of non-cellular, circulating prostate-specific mRNAs.

  8. Sensory system plasticity in a visually specialized, nocturnal spider.

    Science.gov (United States)

    Stafstrom, Jay A; Michalik, Peter; Hebets, Eileen A

    2017-04-21

    The interplay between an animal's environmental niche and its behavior can influence the evolutionary form and function of its sensory systems. While intraspecific variation in sensory systems has been documented across distant taxa, fewer studies have investigated how changes in behavior might relate to plasticity in sensory systems across developmental time. To investigate the relationships among behavior, peripheral sensory structures, and central processing regions in the brain, we take advantage of a dramatic within-species shift of behavior in a nocturnal, net-casting spider (Deinopis spinosa), where males cease visually-mediated foraging upon maturation. We compared eye diameters and brain region volumes across sex and life stage, the latter through micro-computed X-ray tomography. We show that mature males possess altered peripheral visual morphology when compared to their juvenile counterparts, as well as juvenile and mature females. Matching peripheral sensory structure modifications, we uncovered differences in relative investment in both lower-order and higher-order processing regions in the brain responsible for visual processing. Our study provides evidence for sensory system plasticity when individuals dramatically change behavior across life stages, uncovering new avenues of inquiry focusing on altered reliance of specific sensory information when entering a new behavioral niche.

  9. Micromethod for determination of cortisol in peripheral blood

    International Nuclear Information System (INIS)

    Maleeva, A.; Mileva, Zh.; Kekhajova, M.

    1982-01-01

    The micromethod for determination of cortisol in peripheral blood is based on the classical radiommunologic method for its determination. A drop of peripheral blood is applied on filter paper, used for detection of phenyketonuria. A 7 mm disk of this paper is then cut with a perforator and placed in the tube instead of 50 microliters blood plasma. The classical radiommunoassay and the micromethod were used in parallel for determining peripheral blood cortisol concentrations in 26 sexually mature persons, in 12 children and in 40 patients with thyroid hyperfunction. In all tested 78 persons no statistically significant difference (P>0.5) was found in cortisol concentrations, determined by the two methods. (authors)

  10. Influence of anaerobic physical effort in the horizontal and vertical peripheral view INFLUENCIA DEL ESFUERZO FÍSICO ANAERÓBICO EN LA VISIÓN PERIFÉRICA VERTICAL Y HORIZONTAL

    Directory of Open Access Journals (Sweden)

    M. Arteaga

    2010-09-01

    Full Text Available

    There now seems to be a generalized tendency to consider that sporting performance declines as the sportsperson becomes fatigued. However, there is little empirical evidence to show that this adversely affects visual function. In some sports it is necessary to see stimuli in zones peripheral to central vision. The aim of this study is to analyze the influence of anaerobic exertion on vertical and horizontal Peripheral Vision. An intra-subject design was used with 14 replications. The visual parameters of Vertical Peripheral Vision and Horizontal Peripheral Vision were measured in different fatigue conditions to analyze the possible negative influence which this could exert on the subject’s visual capacity. The results show that fatigue due to anaerobic effort does not harm the visual abilities studied.
    KEY WORDS: Peripheral Vision, Fatigue, Anaerobic exertion, Visual abilities

    Parece haber una tendencia generalizada a considerar que el rendimiento deportivo disminuye en la medida en que los deportistas acumulan fatiga; sin embargo existen pocas evidencias empíricas que indiquen que la función visual se vea perjudicada por este motivo. En algunos deportes es necesario observar estímulos en zonas periféricas a la visión central. En el presente estudio se pretende analizar la influencia de los esfuerzos anaeeróbicos sobre la Visión Periférica (vertical y horizontal. Se utilizó un diseño intrasujeto A-(B1,B2-A con catorce replicaciones. Se realizaron mediciones de los parámetros visuales: Visión Periférica Vertical y Visión Periférica Horizontal en diferentes condiciones de fatiga para analizar la posible influencia negativa que pudiera ejercer ésta sobre la capacidad visual de los sujetos. Los resultados permiten afirmar que la fatiga debida a esfuerzos de tipo anaeróbico no producen un perjuicio sobre las habilidades visuales estudiadas.
    PALABRAS CLAVE: Visi

  11. Exploring BOLD changes during spatial attention in non-stimulated visual cortex.

    Directory of Open Access Journals (Sweden)

    Linda Heinemann

    Full Text Available Blood oxygen level-dependent (BOLD responses were measured in parts of primary visual cortex that represented unstimulated visual field regions at different distances from a stimulated central target location. The composition of the visual scene varied by the presence or absence of additional peripheral distracter stimuli. Bottom-up effects were assessed by comparing peripheral activity during central stimulation vs. no stimulation. Top-down effects were assessed by comparing active vs. passive conditions. In passive conditions subjects simply watched the central letter stimuli and in active conditions they had to report occurrence of pre-defined targets in a rapid serial letter stream. Onset of the central letter stream enhanced activity in V1 representations of the stimulated region. Within representations of the periphery activation decreased and finally turned into deactivation with increasing distance from the stimulated location. This pattern was most pronounced in the active conditions and during the presence of peripheral stimuli. Active search for a target did not lead to additional enhancement at areas representing the attentional focus but to a stronger deactivation in the vicinity. Suppressed neuronal activity was also found in the non distracter condition suggesting a top-down attention driven effect. Our observations suggest that BOLD signal decreases in primary visual cortex are modulated by bottom-up sensory-driven factors such as the presence of distracters in the visual field as well as by top-down attentional processes.

  12. Visual performance on detection tasks with double-targets of the same and different difficulty.

    Science.gov (United States)

    Chan, Alan H S; Courtney, Alan J; Ma, C W

    2002-10-20

    This paper reports a study of measurement of horizontal visual sensitivity limits for 16 subjects in single-target and double-targets detection tasks. Two phases of tests were conducted in the double-targets task; targets of the same difficulty were tested in phase one while targets of different difficulty were tested in phase two. The range of sensitivity for the double-targets test was found to be smaller than that for single-target in both the same and different target difficulty cases. The presence of another target was found to affect performance to a marked degree. Interference effect of the difficult target on detection of the easy one was greater than that of the easy one on the detection of the difficult one. Performance decrement was noted when correct percentage detection was plotted against eccentricity of target in both the single-target and double-targets tests. Nevertheless, the non-significant correlation found between the performance for the two tasks demonstrated that it was impossible to predict quantitatively ability for detection of double targets from the data for single targets. This indicated probable problems in generalizing data for single target visual lobes to those for multiple targets. Also lobe area values obtained from measurements using a single-target task cannot be applied in a mathematical model for situations with multiple occurrences of targets.

  13. Accuracy of monofilament testing to diagnose peripheral neuropathy: a systematic review

    NARCIS (Netherlands)

    Dros, Jacquelien; Wewerinke, Astrid; Bindels, Patrick J.; van Weert, Henk C.

    2009-01-01

    We wanted to summarize evidence about the diagnostic accuracy of the 5.07/10-g monofilament test in peripheral neuropathy. We conducted a systematic review of studies in which the accuracy of the 5.07/10-g monofilament was evaluated to detect peripheral neuropathy of any cause using nerve conduction

  14. Accuracy of Monofilament Testing to Diagnose Peripheral Neuropathy: A Systematic Review

    NARCIS (Netherlands)

    Dros, J.; Wewerinke, A.; Bindels, P.J.; van Weert, H.C.

    2009-01-01

    PURPOSE We wanted to summarize evidence about the diagnostic accuracy of the 5.07/10-g monofilament test in peripheral neuropathy. METHODS We conducted a systematic review of studies in which the accuracy of the 5.07/10-g monofilament was evaluated to detect peripheral neuropathy of any cause using

  15. Detecting wood surface defects with fusion algorithm of visual saliency and local threshold segmentation

    Science.gov (United States)

    Wang, Xuejuan; Wu, Shuhang; Liu, Yunpeng

    2018-04-01

    This paper presents a new method for wood defect detection. It can solve the over-segmentation problem existing in local threshold segmentation methods. This method effectively takes advantages of visual saliency and local threshold segmentation. Firstly, defect areas are coarsely located by using spectral residual method to calculate global visual saliency of them. Then, the threshold segmentation of maximum inter-class variance method is adopted for positioning and segmenting the wood surface defects precisely around the coarse located areas. Lastly, we use mathematical morphology to process the binary images after segmentation, which reduces the noise and small false objects. Experiments on test images of insect hole, dead knot and sound knot show that the method we proposed obtains ideal segmentation results and is superior to the existing segmentation methods based on edge detection, OSTU and threshold segmentation.

  16. Visual mismatch negativity indicates automatic, task-independent detection of artistic image composition in abstract artworks.

    Science.gov (United States)

    Menzel, Claudia; Kovács, Gyula; Amado, Catarina; Hayn-Leichsenring, Gregor U; Redies, Christoph

    2018-05-06

    In complex abstract art, image composition (i.e., the artist's deliberate arrangement of pictorial elements) is an important aesthetic feature. We investigated whether the human brain detects image composition in abstract artworks automatically (i.e., independently of the experimental task). To this aim, we studied whether a group of 20 original artworks elicited a visual mismatch negativity when contrasted with a group of 20 images that were composed of the same pictorial elements as the originals, but in shuffled arrangements, which destroy artistic composition. We used a passive oddball paradigm with parallel electroencephalogram recordings to investigate the detection of image type-specific properties. We observed significant deviant-standard differences for the shuffled and original images, respectively. Furthermore, for both types of images, differences in amplitudes correlated with the behavioral ratings of the images. In conclusion, we show that the human brain can detect composition-related image properties in visual artworks in an automatic fashion. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Micro-calibration of space and motion by photoreceptors synchronized in parallel with cortical oscillations: A unified theory of visual perception.

    Science.gov (United States)

    Jerath, Ravinder; Cearley, Shannon M; Barnes, Vernon A; Jensen, Mike

    2018-01-01

    A fundamental function of the visual system is detecting motion, yet visual perception is poorly understood. Current research has determined that the retina and ganglion cells elicit responses for motion detection; however, the underlying mechanism for this is incompletely understood. Previously we proposed that retinogeniculo-cortical oscillations and photoreceptors work in parallel to process vision. Here we propose that motion could also be processed within the retina, and not in the brain as current theory suggests. In this paper, we discuss: 1) internal neural space formation; 2) primary, secondary, and tertiary roles of vision; 3) gamma as the secondary role; and 4) synchronization and coherence. Movement within the external field is instantly detected by primary processing within the space formed by the retina, providing a unified view of the world from an internal point of view. Our new theory begins to answer questions about: 1) perception of space, erect images, and motion, 2) purpose of lateral inhibition, 3) speed of visual perception, and 4) how peripheral color vision occurs without a large population of cones located peripherally in the retina. We explain that strong oscillatory activity influences on brain activity and is necessary for: 1) visual processing, and 2) formation of the internal visuospatial area necessary for visual consciousness, which could allow rods to receive precise visual and visuospatial information, while retinal waves could link the lateral geniculate body with the cortex to form a neural space formed by membrane potential-based oscillations and photoreceptors. We propose that vision is tripartite, with three components that allow a person to make sense of the world, terming them "primary, secondary, and tertiary roles" of vision. Finally, we propose that Gamma waves that are higher in strength and volume allow communication among the retina, thalamus, and various areas of the cortex, and synchronization brings cortical

  18. Predicting visual acuity from detection thresholds.

    Science.gov (United States)

    Newacheck, J S; Haegerstrom-Portnoy, G; Adams, A J

    1990-03-01

    Visual performance based exclusively on high luminance and high contrast letter acuity measures often fails to predict individual performance at low contrast and low luminance. Here we measured visual acuity over a wide range of contrasts and luminances (low mesopic to photopic) for 17 young normal observers. Acuity vs. contrast functions appear to fit a single template which can be displaced laterally along the log contrast axis. The magnitude of this lateral displacement for different luminances was well predicted by the contrast threshold difference for a 4 min arc spot. The acuity vs. contrast template, taken from the mean of all 17 subjects, was used in conjunction with individual spot contrast threshold measures to predict an individual's visual acuity over a wide range of luminance and contrast levels. The accuracy of the visual acuity predictions from this simple procedure closely approximates test-retest accuracy for both positive (projected Landolt rings) and negative contrast (Bailey-Lovie charts).

  19. Detecting and visualizing internal 3D oleoresin in agarwood by means of micro-computed tomography

    International Nuclear Information System (INIS)

    Khairiah Yazid; Roslan Yahya; Mat Rosol Awang

    2012-01-01

    Detection and analysis of oleoresin is particularly significant since the commercial value of agarwood is related to the quantity of oleoresins that are present. A modern technique of non-destructive may reach the interior region of the wood. Currently, tomographic image data in particular is most commonly visualized in three dimensions using volume rendering. The aim of this paper is to explore the potential of high resolution non-destructive 3D visualization technique, X-ray micro-computed tomography, as imaging tools to visualize micro-structure oleoresin in agarwood. Investigations involving desktop X-ray micro-tomography system on high grade agarwood sample, performed at the Centre of Tomography in Nuclear Malaysia, demonstrate the applicability of the method. Prior to experiments, a reference test was conducted to stimulate the attenuation of oleoresin in agarwood. Based on the experiment results, micro-CT imaging with voxel size 7.0 μm is capable to of detecting oleoresin and pores in agarwood. This imaging technique, although sophisticated can be used for standard development especially in grading of agarwood for commercial activities. (author)

  20. Endpoint visual detection of three genetically modified rice events by loop-mediated isothermal amplification.

    Science.gov (United States)

    Chen, Xiaoyun; Wang, Xiaofu; Jin, Nuo; Zhou, Yu; Huang, Sainan; Miao, Qingmei; Zhu, Qing; Xu, Junfeng

    2012-11-07

    Genetically modified (GM) rice KMD1, TT51-1, and KF6 are three of the most well known transgenic Bt rice lines in China. A rapid and sensitive molecular assay for risk assessment of GM rice is needed. Polymerase chain reaction (PCR), currently the most common method for detecting genetically modified organisms, requires temperature cycling and relatively complex procedures. Here we developed a visual and rapid loop-mediated isothermal amplification (LAMP) method to amplify three GM rice event-specific junction sequences. Target DNA was amplified and visualized by two indicators (SYBR green or hydroxy naphthol blue [HNB]) within 60 min at an isothermal temperature of 63 °C. Different kinds of plants were selected to ensure the specificity of detection and the results of the non-target samples were negative, indicating that the primer sets for the three GM rice varieties had good levels of specificity. The sensitivity of LAMP, with detection limits at low concentration levels (0.01%−0.005% GM), was 10- to 100-fold greater than that of conventional PCR. Additionally, the LAMP assay coupled with an indicator (SYBR green or HNB) facilitated analysis. These findings revealed that the rapid detection method was suitable as a simple field-based test to determine the status of GM crops.

  1. Endpoint Visual Detection of Three Genetically Modified Rice Events by Loop-Mediated Isothermal Amplification

    Directory of Open Access Journals (Sweden)

    Qing Zhu

    2012-11-01

    Full Text Available Genetically modified (GM rice KMD1, TT51-1, and KF6 are three of the most well known transgenic Bt rice lines in China. A rapid and sensitive molecular assay for risk assessment of GM rice is needed. Polymerase chain reaction (PCR, currently the most common method for detecting genetically modified organisms, requires temperature cycling and relatively complex procedures. Here we developed a visual and rapid loop-mediated isothermal amplification (LAMP method to amplify three GM rice event-specific junction sequences. Target DNA was amplified and visualized by two indicators (SYBR green or hydroxy naphthol blue [HNB] within 60 min at an isothermal temperature of 63 °C. Different kinds of plants were selected to ensure the specificity of detection and the results of the non-target samples were negative, indicating that the primer sets for the three GM rice varieties had good levels of specificity. The sensitivity of LAMP, with detection limits at low concentration levels (0.01%–0.005% GM, was 10- to 100-fold greater than that of conventional PCR. Additionally, the LAMP assay coupled with an indicator (SYBR green or HNB facilitated analysis. These findings revealed that the rapid detection method was suitable as a simple field-based test to determine the status of GM crops.

  2. Contrast and strength of visual memory and imagery differentially affect visual perception.

    Science.gov (United States)

    Saad, Elyana; Silvanto, Juha

    2013-01-01

    Visual short-term memory (VSTM) and visual imagery have been shown to modulate visual perception. However, how the subjective experience of VSTM/imagery and its contrast modulate this process has not been investigated. We addressed this issue by asking participants to detect brief masked targets while they were engaged either in VSTM or visual imagery. Subjective experience of memory/imagery (strength scale), and the visual contrast of the memory/mental image (contrast scale) were assessed on a trial-by-trial basis. For both VSTM and imagery, contrast of the memory/mental image was positively associated with reporting target presence. Consequently, at the sensory level, both VSTM and imagery facilitated visual perception. However, subjective strength of VSTM was positively associated with visual detection whereas the opposite pattern was found for imagery. Thus the relationship between subjective strength of memory/imagery and visual detection are qualitatively different for VSTM and visual imagery, although their impact at the sensory level appears similar. Our results furthermore demonstrate that imagery and VSTM are partly dissociable processes.

  3. Contrast and strength of visual memory and imagery differentially affect visual perception.

    Directory of Open Access Journals (Sweden)

    Elyana Saad

    Full Text Available Visual short-term memory (VSTM and visual imagery have been shown to modulate visual perception. However, how the subjective experience of VSTM/imagery and its contrast modulate this process has not been investigated. We addressed this issue by asking participants to detect brief masked targets while they were engaged either in VSTM or visual imagery. Subjective experience of memory/imagery (strength scale, and the visual contrast of the memory/mental image (contrast scale were assessed on a trial-by-trial basis. For both VSTM and imagery, contrast of the memory/mental image was positively associated with reporting target presence. Consequently, at the sensory level, both VSTM and imagery facilitated visual perception. However, subjective strength of VSTM was positively associated with visual detection whereas the opposite pattern was found for imagery. Thus the relationship between subjective strength of memory/imagery and visual detection are qualitatively different for VSTM and visual imagery, although their impact at the sensory level appears similar. Our results furthermore demonstrate that imagery and VSTM are partly dissociable processes.

  4. Visual signal detection in structured backgrounds. II. Effects of contrast gain control, background variations, and white noise

    Science.gov (United States)

    Eckstein, M. P.; Ahumada, A. J. Jr; Watson, A. B.

    1997-01-01

    Studies of visual detection of a signal superimposed on one of two identical backgrounds show performance degradation when the background has high contrast and is similar in spatial frequency and/or orientation to the signal. To account for this finding, models include a contrast gain control mechanism that pools activity across spatial frequency, orientation and space to inhibit (divisively) the response of the receptor sensitive to the signal. In tasks in which the observer has to detect a known signal added to one of M different backgrounds grounds due to added visual noise, the main sources of degradation are the stochastic noise in the image and the suboptimal visual processing. We investigate how these two sources of degradation (contrast gain control and variations in the background) interact in a task in which the signal is embedded in one of M locations in a complex spatially varying background (structured background). We use backgrounds extracted from patient digital medical images. To isolate effects of the fixed deterministic background (the contrast gain control) from the effects of the background variations, we conduct detection experiments with three different background conditions: (1) uniform background, (2) a repeated sample of structured background, and (3) different samples of structured background. Results show that human visual detection degrades from the uniform background condition to the repeated background condition and degrades even further in the different backgrounds condition. These results suggest that both the contrast gain control mechanism and the background random variations degrade human performance in detection of a signal in a complex, spatially varying background. A filter model and added white noise are used to generate estimates of sampling efficiencies, an equivalent internal noise, an equivalent contrast-gain-control-induced noise, and an equivalent noise due to the variations in the structured background.

  5. On detection and visualization techniques for cyber security situation awareness

    Science.gov (United States)

    Yu, Wei; Wei, Shixiao; Shen, Dan; Blowers, Misty; Blasch, Erik P.; Pham, Khanh D.; Chen, Genshe; Zhang, Hanlin; Lu, Chao

    2013-05-01

    Networking technologies are exponentially increasing to meet worldwide communication requirements. The rapid growth of network technologies and perversity of communications pose serious security issues. In this paper, we aim to developing an integrated network defense system with situation awareness capabilities to present the useful information for human analysts. In particular, we implement a prototypical system that includes both the distributed passive and active network sensors and traffic visualization features, such as 1D, 2D and 3D based network traffic displays. To effectively detect attacks, we also implement algorithms to transform real-world data of IP addresses into images and study the pattern of attacks and use both the discrete wavelet transform (DWT) based scheme and the statistical based scheme to detect attacks. Through an extensive simulation study, our data validate the effectiveness of our implemented defense system.

  6. Effects of Motion in the Far Peripheral Visual Field on Cognitive Test Performance and Cognitive Load.

    Science.gov (United States)

    Bevilacqua, Andy; Paas, Fred; Krigbaum, Genomary

    2016-04-01

    Cognitive load theory posits that limited attention is in actuality a limitation in working memory resources. The load theory of selective attention and cognitive control sees the interplay between attention and awareness as separate modifying functions that act on working memory. Reconciling the theoretical differences in these two theories has important implications for learning. Thirty-nine adult participants performed a cognitively demanding test, with and without movement in the far peripheral field. Although the results for movement effects on cognitive load in this experiment were not statistically significant, men spent less time on the cognitive test in the peripheral movement condition than in the conditions without peripheral movement. No such difference was found for women. The implications of these results and recommendations for future research that extends the present study are presented. © The Author(s) 2016.

  7. Micronucleus test for radiation biodosimetry in mass casualty events: Evaluation of visual and automated scoring

    Energy Technology Data Exchange (ETDEWEB)

    Bolognesi, Claudia, E-mail: claudia.bolognesi@istge.i [Environmental Carcinogenesis Unit, National Cancer Research Institute, Largo R. Benzi 10, 16132 Genoa (Italy); Balia, Cristina; Roggieri, Paola [Environmental Carcinogenesis Unit, National Cancer Research Institute, Largo R. Benzi 10, 16132 Genoa (Italy); Cardinale, Francesco [Clinical Epidemiology Unit, National Cancer Research Institute, Largo R. Benzi 10, 16132 Genoa (Italy); Department of Health Sciences, University of Genoa, Genoa (Italy); Bruzzi, Paolo [Clinical Epidemiology Unit, National Cancer Research Institute, Largo R. Benzi 10, 16132 Genoa (Italy); Sorcinelli, Francesca [Environmental Carcinogenesis Unit, National Cancer Research Institute, Largo R. Benzi 10, 16132 Genoa (Italy); Laboratory of Genetics, Histology and Molecular Biology Section, Army Medical and Veterinary, Research Center, Via Santo Stefano Rotondo 4, 00184 Roma (Italy); Lista, Florigio [Laboratory of Genetics, Histology and Molecular Biology Section, Army Medical and Veterinary, Research Center, Via Santo Stefano Rotondo 4, 00184 Roma (Italy); D' Amelio, Raffaele [Sapienza, Universita di Roma II Facolta di Medicina e Chirurgia and Ministero della Difesa, Direzione Generale Sanita Militare (Italy); Righi, Enzo [Frascati National Laboratories, National Institute of Nuclear Physics, Via Enrico Fermi 40, 00044 Frascati, Rome (Italy)

    2011-02-15

    In the case of a large-scale nuclear or radiological incidents a reliable estimate of dose is an essential tool for providing timely assessment of radiation exposure and for making life-saving medical decisions. Cytogenetics is considered as the 'gold standard' for biodosimetry. The dicentric analysis (DA) represents the most specific cytogenetic bioassay. The micronucleus test (MN) applied in interphase in peripheral lymphocytes is an alternative and simpler approach. A dose-effect calibration curve for the MN frequency in peripheral lymphocytes from 27 adult donors was established after in vitro irradiation at a dose range 0.15-8 Gy of {sup 137}Cs gamma rays (dose rate 6 Gy min{sup -1}). Dose prediction by visual scoring in a dose-blinded study (0.15-4.0 Gy) revealed a high level of accuracy (R = 0.89). The scoring of MN is time consuming and requires adequate skills and expertise. Automated image analysis is a feasible approach allowing to reduce the time and to increase the accuracy of the dose estimation decreasing the variability due to subjective evaluation. A good correlation (R = 0.705) between visual and automated scoring with visual correction was observed over the dose range 0-2 Gy. Almost perfect discrimination power for exposure to 1-2 Gy, and a satisfactory power for 0.6 Gy were detected. This threshold level can be considered sufficient for identification of sub lethally exposed individuals by automated CBMN assay.

  8. Visual detection of arginine, histidine and lysine using quercetin-functionalized gold nanoparticles

    International Nuclear Information System (INIS)

    Rawat, Karuna A.; Kailasa, Suresh Kumar

    2014-01-01

    We report on the use of quercetin-functionalized gold nanoparticles (QC-AuNPs) as a colorimetric probe for the amino acids arginine (Arg), histidine (His) and lysine (Lys). The method is based on the aggregation of the QC-AuNPs that is caused by these amino acids and leads to a visually detectable color change from red to blue. The absorption maxima shift from 525 nm to 702, 693, and 745 nm, respectively. Aggregations are confirmed by dynamic light scattering (DLS) and transmission electron microscopic techniques (TEM). The effects of the QC concentration, temperature and reaction time for the preparation of QC-Au NPs were tested. Other amino acids do not interfere. Under the optimal conditions, linear relationships exist between the absorption ratios at 702/525 nm (for Arg), 693/525 nm (for His), and 745/525 nm (for Lys) over the concentrations ranges from 2.5–1,250 μM (Arg) and 1–1,000 μM (His and Lys), respectively. The respective limits of detection are 0.04, 0.03, and 0.02 μM. The method provides a useful tool for the rapid visual and instrumental determination of the three amino acids. (author)

  9. Electrochromic Molecular Imprinting Sensor for Visual and Smartphone-Based Detections.

    Science.gov (United States)

    Capoferri, Denise; Álvarez-Diduk, Ruslan; Del Carlo, Michele; Compagnone, Dario; Merkoçi, Arben

    2018-05-01

    Electrochromic effect and molecularly imprinted technology have been used to develop a sensitive and selective electrochromic sensor. The polymeric matrices obtained using the imprinting technology are robust molecular recognition elements and have the potential to mimic natural recognition entities with very high selectivity. The electrochromic behavior of iridium oxide nanoparticles (IrOx NPs) as physicochemical transducer together with a molecularly imprinted polymer (MIP) as recognition layer resulted in a fast and efficient translation of the detection event. The sensor was fabricated using screen-printing technology with indium tin oxide as a transparent working electrode; IrOx NPs where electrodeposited onto the electrode followed by thermal polymerization of polypyrrole in the presence of the analyte (chlorpyrifos). Two different approaches were used to detect and quantify the pesticide: direct visual detection and smartphone imaging. Application of different oxidation potentials for 10 s resulted in color changes directly related to the concentration of the analyte. For smartphone imaging, at fixed potential, the concentration of the analyte was dependent on the color intensity of the electrode. The electrochromic sensor detects a highly toxic compound (chlorpyrifos) with a 100 fM and 1 mM dynamic range. So far, to the best of our knowledge, this is the first work where an electrochromic MIP sensor uses the electrochromic properties of IrOx to detect a certain analyte with high selectivity and sensitivity.

  10. Visual Impairment Secondary to Unilateral Isolated Epicapsular Star

    Directory of Open Access Journals (Sweden)

    Mehmet Serhat Mangan

    2014-12-01

    Full Text Available We aimed to report a rarely observed case of unilateral epicapsular star and the visual impairment developed secondary to it. A 8-year-old girl presented with a complaint of blurred vision in the right eye; best-corrected visual acuity was 0.7 in the right eye and 1.0 in the left eye. Near visual acuity was J1 in the right eye and J1+ in the left eye. The patient had no systemic disease and no clinical findings such as ocular inflammation, trauma, or history of use of topical and systemic drug. On biomicroscopic examination, no pigment deposition was observed in the cornea of both eyes and anterior chamber was normal. The anterior capsule of the lens in the right eye demonstrated dense pigment depositions centrally which were obscuring the pupillary axis. Iris translumination defect was not seen. Gonioscopy was performed and no pigment deposition was seen in the iridocorneal angle. Fundus examination revealed no pathology in the vitreous, posterior pole, and peripheral retina. In the absence of signs of intraocular inflammation and other causes of primary or secondary pigment dispersion, it is likely that the pigmented cells were implanted on the lens surface in utero from the developing iris pigment epithelium. In such cases, visual impairment should be detected in early period, and the strict follow-up is of utmost importance. (Turk J Ophthalmol 2014; 44: 493-5

  11. Detecting gradual visual changes in colour and brightness agnosia: a double dissociation.

    Science.gov (United States)

    Nijboer, Tanja C W; te Pas, Susan F; van der Smagt, Maarten J

    2011-03-09

    Two patients, one with colour agnosia and one with brightness agnosia, performed a task that required the detection of gradual temporal changes in colour and brightness. The results for these patients, who showed anaverage or an above-average performance on several tasks designed to test low-level colour and luminance (contrast) perception in the spatial domain, yielded a double dissociation; the brightness agnosic patient was within the normal range for the coloured stimuli, but much slower to detect brightness differences, whereas the colour agnosic patient was within the normal range for the achromatic stimuli, but much slower for the coloured stimuli. These results suggest that a modality-specific impairment in the detection of gradual temporal changes might be related to, if not underlie, the phenomenon of visual agnosia.

  12. Detection of canine distemper virus nucleocapsid protein gene in canine peripheral blood mononuclear cells by RT-PCR.

    Science.gov (United States)

    Shin, Y; Mori, T; Okita, M; Gemma, T; Kai, C; Mikami, T

    1995-06-01

    For a rapid diagnosis of canine distemper virus (CDV) infection, the reverse transcription-PCR (RT-PCR) was carried out to detect CDV nucleoprotein (NP) gene from canine peripheral blood mononuclear cells (PBMCs). Two sets of primers were targeted to two regions of NP gene of CDV Onderstepoort strain. The NP gene fragments were well amplified by the RT-PCR in each of the RNA extracts from Vero cells infected with 6 laboratory strains of CDV including Onderstepoort strain, and from PBMCs of a dog experimentally infected with CDV. The amplified NP gene was detected in 17 of 32 samples from dogs which were clinically suspected for CDV infection at veterinary hospitals. No RT-PCR product was found in 52 samples from healthy dogs including 40 specific pathogen free beagles vaccinated with an attenuated live virus-vaccine for CDV and 12 stray dogs. The RT-PCR provides a fast, sensitive, and supplementary method for the diagnosis of CDV infection in dogs.

  13. Radionuclide lymphoscintigraphy in the evaluation of peripheral edema

    International Nuclear Information System (INIS)

    Kim, Soon; Zeon, Seok Kil

    2000-01-01

    It has been difficulty to visualize lymphatics in living patients. Conventional or direct lymphography has been the gold standard for delineation of the lymphatic system, but this procedure is invasive, difficulty to perform, and harmful to the lymphatic vascular endothelium. The aim of our study was to determine its severity, and to understand the drainage patterns on patients with peripheral edema by functional lymphatic studies. Tc-99m antimony sulfide colloid 25 MBq with 0.4 ml volume was injected intradermally in the first, second and third web space of the foot or hand in 40 patients with peripheral edema (5 in upper extremity and 35 in lower extremity). Initial flow after injection and whole body images at approximately 30 minutes. 1-4 hours were obtained. In 9/40 cases with peripheral edema normal lymphoscintigram were revealed, primary lymphedema was observed in 5/31 cases. The imaging patterns in primary lymphedema were absent (3 cases) or delayed (2 cases) transport, lymphatic duct dilatation (1), cutoff (1), decrease in size and number of lymph nodes (2). The Common caused of edema in secondry lymphedema (26/31) were carcinoma (13), inflammation (5), post-operation (5), and unknown origin (3). The common imaging findings in carcinoma showed non-visualization of lymph nodes (13), dermal backflow (8), collateral circulation (5), and in inflammation lymphatic obstruction (2), increase in size and number of lymph nodes (2), delayed transport (1), and in post-operation dermal backflow (3), delayed transport (2), decrease in number and size of lymph node (2) Clear images patterns were observed difference between primary lymphedema an secondary lymphedema. Radionuclide lymphoscintigraphy is essentially non-invasive, easy to perform repeatedly, and harmless to the lymphatic vascular endothelium for evaluation of a patient with lymphedema

  14. Immunoglobulin deposits in peripheral nerve endings detected by skin biopsy in patients with IgM M proteins and neuropathy

    DEFF Research Database (Denmark)

    Jønsson, V; Jensen, T S; Friis, M L

    1987-01-01

    biopsies provide a simple effective method of detecting immunoglobulin binding to peripheral nerves in patients suspected of having an autoimmune neuropathy. In contrast to sural nerve biopsy, skin biopsy does not cause sensory loss or pain in a denervated area and can easily be repeated.......Immunofluorescence studies of sural nerve and skin biopsies from three patients with IgM M proteins and clinical neuropathy showed that IgM M protein was bound to the nerve myelin in two patients and by the peri- and endoneurium in one. It is suggested that immunohistochemical studies of skin...

  15. Orienting Attention within Visual Short-Term Memory: Development and Mechanisms

    Science.gov (United States)

    Shimi, Andria; Nobre, Anna C.; Astle, Duncan; Scerif, Gaia

    2014-01-01

    How does developing attentional control operate within visual short-term memory (VSTM)? Seven-year-olds, 11-year-olds, and adults (total n = 205) were asked to report whether probe items were part of preceding visual arrays. In Experiment 1, central or peripheral cues oriented attention to the location of to-be-probed items either prior to…

  16. High-resolution ultrasound imaging and noninvasive optoacoustic monitoring of blood variables in peripheral blood vessels

    Science.gov (United States)

    Petrov, Irene Y.; Petrov, Yuriy; Prough, Donald S.; Esenaliev, Rinat O.

    2011-03-01

    Ultrasound imaging is being widely used in clinics to obtain diagnostic information non-invasively and in real time. A high-resolution ultrasound imaging platform, Vevo (VisualSonics, Inc.) provides in vivo, real-time images with exceptional resolution (up to 30 microns) using high-frequency transducers (up to 80 MHz). Recently, we built optoacoustic systems for probing radial artery and peripheral veins that can be used for noninvasive monitoring of total hemoglobin concentration, oxyhemoglobin saturation, and concentration of important endogenous and exogenous chromophores (such as ICG). In this work we used the high-resolution ultrasound imaging system Vevo 770 for visualization of the radial artery and peripheral veins and acquired corresponding optoacoustic signals from them using the optoacoustic systems. Analysis of the optoacoustic data with a specially developed algorithm allowed for measurement of blood oxygenation in the blood vessels as well as for continuous, real-time monitoring of arterial and venous blood oxygenation. Our results indicate that: 1) the optoacoustic technique (unlike pure optical approaches and other noninvasive techniques) is capable of accurate peripheral venous oxygenation measurement; and 2) peripheral venous oxygenation is dependent on skin temperature and local hemodynamics. Moreover, we performed for the first time (to the best of our knowledge) a comparative study of optoacoustic arterial oximetry and a standard pulse oximeter in humans and demonstrated superior performance of the optoacoustic arterial oximeter, in particular at low blood flow.

  17. Tumors of peripheral nerves; Tumoren der peripheren Nerven

    Energy Technology Data Exchange (ETDEWEB)

    Ho, Michael [Universitaetsklinikum Zuerich, Institut fuer Diagnostische Radiologie, Zuerich (Switzerland); Lutz, Amelie M. [Stanford University School of Medicine, Department of Radiology, Stanford, CA (United States)

    2017-03-15

    Differentiation between malignant and benign tumors of peripheral nerves in the early stages is challenging; however, due to the unfavorable prognosis of malignant tumors early identification is required. To show the possibilities for detection, differential diagnosis and clinical management of peripheral nerve tumors by imaging appearance in magnetic resonance (MR) neurography. Review of current literature available in PubMed and MEDLINE, supplemented by the authors' own observations in clinical practice. Although not pathognomonic, several imaging features have been reported for a differentiation between distinct peripheral nerve tumors. The use of MR neurography enables detection and initial differential diagnosis in tumors of peripheral nerves. Furthermore, it plays an important role in clinical follow-up, targeted biopsy and surgical planning. (orig.) [German] Die Unterscheidung zwischen malignen und benignen Tumoren der peripheren Nerven ist im initialen Stadium schwierig. Die Frueherkennung der malignen Tumoren ist aufgrund ihrer unguenstigen Prognose jedoch wichtig. Moeglichkeiten der MR-Neurographie zur Detektion, Artdiagnostik und klinischem Management von Tumoren der peripheren Nerven anhand bildmorphologischer Charakteristika. Zusammenschau der Studienlage mittels PubMed- bzw. MEDLINE-Recherche. Zusaetzlich Darlegung teils unveroeffentlichter Erkenntnisse aus der eigenen klinischen Beobachtung. Wenn auch nicht pathognomonisch, existieren verschiedene Bildgebungszeichen zur moeglichen Unterscheidung verschiedener Tumoren der peripheren Nerven. Die MR-Neurographie ist ein geeignetes bildgebendes Verfahren zur Detektion und ersten Differenzialdiagnose von Tumoren der peripheren Nerven. Zudem kommt ihr besondere Bedeutung bei der Verlaufskontrolle, der gezielten Biopsie und der operativen Planung zu. (orig.)

  18. Change blindness and visual memory: visual representations get rich and act poor.

    Science.gov (United States)

    Varakin, D Alexander; Levin, Daniel T

    2006-02-01

    Change blindness is often taken as evidence that visual representations are impoverished, while successful recognition of specific objects is taken as evidence that they are richly detailed. In the current experiments, participants performed cover tasks that required each object in a display to be attended. Change detection trials were unexpectedly introduced and surprise recognition tests were given for nonchanging displays. For both change detection and recognition, participants had to distinguish objects from the same basic-level category, making it likely that specific visual information had to be used for successful performance. Although recognition was above chance, incidental change detection usually remained at floor. These results help reconcile demonstrations of poor change detection with demonstrations of good memory because they suggest that the capability to store visual information in memory is not reflected by the visual system's tendency to utilize these representations for purposes of detecting unexpected changes.

  19. Two-stage perceptual learning to break visual crowding.

    Science.gov (United States)

    Zhu, Ziyun; Fan, Zhenzhi; Fang, Fang

    2016-01-01

    When a target is presented with nearby flankers in the peripheral visual field, it becomes harder to identify, which is referred to as crowding. Crowding sets a fundamental limit of object recognition in peripheral vision, preventing us from fully appreciating cluttered visual scenes. We trained adult human subjects on a crowded orientation discrimination task and investigated whether crowding could be completely eliminated by training. We discovered a two-stage learning process with this training task. In the early stage, when the target and flankers were separated beyond a certain distance, subjects acquired a relatively general ability to break crowding, as evidenced by the fact that the breaking of crowding could transfer to another crowded orientation, even a crowded motion stimulus, although the transfer to the opposite visual hemi-field was weak. In the late stage, like many classical perceptual learning effects, subjects' performance gradually improved and showed specificity to the trained orientation. We also found that, when the target and flankers were spaced too finely, training could only reduce, rather than completely eliminate, the crowding effect. This two-stage learning process illustrates a learning strategy for our brain to deal with the notoriously difficult problem of identifying peripheral objects in clutter. The brain first learned to solve the "easy and general" part of the problem (i.e., improving the processing resolution and segmenting the target and flankers) and then tackle the "difficult and specific" part (i.e., refining the representation of the target).

  20. Proactive interference does not meaningfully distort visual working memory capacity estimates in the canonical change detection task

    Directory of Open Access Journals (Sweden)

    Po-Han eLin

    2012-02-01

    Full Text Available The change detection task has become a standard method for estimating the storage capacity of visual working memory. Most researchers assume that this task isolates the properties of an active short-term storage system that can be dissociated from long-term memory systems. However, long-term memory storage may influence performance on this task. In particular, memory traces from previous trials may create proactive interference that sometimes leads to errors, thereby reducing estimated capacity. Consequently, the capacity of visual working memory may be higher than is usually thought, and correlations between capacity and other measures of cognition may reflect individual differences in proactive interference rather than individual differences in the capacity of the short-term storage system. Indeed, previous research has shown that change detection performance can be influenced by proactive interference under some conditions. The purpose of the present study was to determine whether the canonical version of the change detection task—in which the to-be-remembered information consists of simple, briefly presented features—is influenced by proactive interference. Two experiments were conducted using methods that ordinarily produce substantial evidence of proactive interference, but no proactive interference was observed. Thus, the canonical version of the change detection task can be used to assess visual working memory capacity with no meaningful influence of proactive interference.

  1. Proactive interference does not meaningfully distort visual working memory capacity estimates in the canonical change detection task.

    Science.gov (United States)

    Lin, Po-Han; Luck, Steven J

    2012-01-01

    The change detection task has become a standard method for estimating the storage capacity of visual working memory. Most researchers assume that this task isolates the properties of an active short-term storage system that can be dissociated from long-term memory systems. However, long-term memory storage may influence performance on this task. In particular, memory traces from previous trials may create proactive interference that sometimes leads to errors, thereby reducing estimated capacity. Consequently, the capacity of visual working memory may be higher than is usually thought, and correlations between capacity and other measures of cognition may reflect individual differences in proactive interference rather than individual differences in the capacity of the short-term storage system. Indeed, previous research has shown that change detection performance can be influenced by proactive interference under some conditions. The purpose of the present study was to determine whether the canonical version of the change detection task - in which the to-be-remembered information consists of simple, briefly presented features - is influenced by proactive interference. Two experiments were conducted using methods that ordinarily produce substantial evidence of proactive interference, but no proactive interference was observed. Thus, the canonical version of the change detection task can be used to assess visual working memory capacity with no meaningful influence of proactive interference.

  2. Rapid intracerebroventricular delivery of Cu-DOTA-etanercept after peripheral administration demonstrated by PET imaging

    Directory of Open Access Journals (Sweden)

    Chen Xiaoyuan

    2009-02-01

    Full Text Available Abstract Background The cytokines interleukin-1 and tumor necrosis factor (TNF, and the cytokine blocker interleukin-1 receptor antagonist, all have been demonstrated to enter the cerebrospinal fluid (CSF following peripheral administration. Recent reports of rapid clinical improvement in patients with Alzheimer's disease and related forms of dementia following perispinal administration of etanercept, a TNF antagonist, suggest that etanercept also has the ability to reach the brain CSF. To investigate, etanercept was labeled with a positron emitter to enable visualization of its intracranial distribution following peripheral administration by PET in an animal model. Findings Radiolabeling of etanercept with the PET emitter 64Cu was performed by DOTA (1,4,7,10-tetraazadodecane-N,N',N",N"'-tetraacetic acid conjugation of etanercept, followed by column purification and 64Cu labeling. MicroPET imaging revealed accumulation of 64Cu-DOTA-etanercept within the lateral and third cerebral ventricles within minutes of peripheral perispinal administration in a normal rat anesthesized with isoflurane anesthesia, with concentration within the choroid plexus and into the CSF. Conclusion Synthesis of 64Cu-DOTA-etanercept enabled visualization of its intracranial distribution by microPET imaging. MicroPET imaging documented rapid accumulation of 64Cu-DOTA-etanercept within the choroid plexus and the cerebrospinal fluid within the cerebral ventricles of a living rat after peripheral administration. Further study of the effects of etanercept and TNF at the level of the choroid plexus may yield valuable insights into the pathogenesis of Alzheimer's disease.

  3. Peripheral global neglect in high versus low autistic tendency

    Directory of Open Access Journals (Sweden)

    Daniel Paul Crewther

    2014-04-01

    Full Text Available In addition to its core social deficits, autism is characterised by altered visual perception, with a preference for local percept in those high in autistic tendency. Here, the balance of global versus local percepts for the perceptually rivalrous diamond illusion was assessed between groups scoring high and low on the Autism Spectrum Quotient (AQ. The global percept of a diamond shape oscillating horizontally behind three occluders can as easily be interpreted as the local percept of four line elements, each moving vertically. Increasing the luminance contrast of the occluders with respect to background resulted in an increase of initial global percept in both groups, with no difference in sensitivity between groups. Presenting the target further into the periphery resulted in a marked increase in the percentage of global perception with visual field eccentricity. However, while the performance for centrally presented diamond targets was not different between AQ groups, the peripheral global performance of the High AQ group was significantly reduced compared with the Low AQ group. On the basis of other imaging studies, this peripheral but not foveal global perceptual neglect may indicate an abnormal interaction between striate cortex and the Lateral Occipital Complex, or to differences in the deployment of attention between the two groups.

  4. Differential contribution of early visual areas to the perceptual process of contour processing.

    Science.gov (United States)

    Schira, Mark M; Fahle, Manfred; Donner, Tobias H; Kraft, Antje; Brandt, Stephan A

    2004-04-01

    We investigated contour processing and figure-ground detection within human retinotopic areas using event-related functional magnetic resonance imaging (fMRI) in 6 healthy and naïve subjects. A figure (6 degrees side length) was created by a 2nd-order texture contour. An independent and demanding foveal letter-discrimination task prevented subjects from noticing this more peripheral contour stimulus. The contour subdivided our stimulus into a figure and a ground. Using localizers and retinotopic mapping stimuli we were able to subdivide each early visual area into 3 eccentricity regions corresponding to 1) the central figure, 2) the area along the contour, and 3) the background. In these subregions we investigated the hemodynamic responses to our stimuli and compared responses with or without the contour defining the figure. No contour-related blood oxygenation level-dependent modulation in early visual areas V1, V3, VP, and MT+ was found. Significant signal modulation in the contour subregions of V2v, V2d, V3a, and LO occurred. This activation pattern was different from comparable studies, which might be attributable to the letter-discrimination task reducing confounding attentional modulation. In V3a, but not in any other retinotopic area, signal modulation corresponding to the central figure could be detected. Such contextual modulation will be discussed in light of the recurrent processing hypothesis and the role of visual awareness.

  5. Nonuniform Changes in the Distribution of Visual Attention from Visual Complexity and Action: A Driving Simulation Study.

    Science.gov (United States)

    Park, George D; Reed, Catherine L

    2015-02-01

    Researchers acknowledge the interplay between action and attention, but typically consider action as a response to successful attentional selection or the correlation of performance on separate action and attention tasks. We investigated how concurrent action with spatial monitoring affects the distribution of attention across the visual field. We embedded a functional field of view (FFOV) paradigm with concurrent central object recognition and peripheral target localization tasks in a simulated driving environment. Peripheral targets varied across 20-60 deg eccentricity at 11 radial spokes. Three conditions assessed the effects of visual complexity and concurrent action on the size and shape of the FFOV: (1) with no background, (2) with driving background, and (3) with driving background and vehicle steering. The addition of visual complexity slowed task performance and reduced the FFOV size but did not change the baseline shape. In contrast, the addition of steering produced not only shrinkage of the FFOV, but also changes in the FFOV shape. Nonuniform performance decrements occurred in proximal regions used for the central task and for steering, independent of interference from context elements. Multifocal attention models should consider the role of action and account for nonhomogeneities in the distribution of attention. © 2015 SAGE Publications.

  6. [Combination surgery for wet age-related macular degeneration and chronic peripheral uveitis].

    Science.gov (United States)

    Zapuskalov, I V; Krivosheina, O I; Khoroshikh, Yu I

    2016-01-01

    To develop a combination surgery for wet age-related macular degeneration and concurrent chronic peripheral uveitis that would include intravitreal injection of Lucentis and cryocerclage of the peripheral retina. A total of 75 patients were examined and divided into 2 groups: the main group (37 patients) and the controls (38 patients). Patients from the main group underwent the new combination surgery, while the controls received intravitreal Lucentis alone (peripheral uveitis was managed therapeutically). It has been found that the new combination method provides a significant and stable improvement in visual acuity (by a factor of 10) and a decrease in the area of central scotoma (by a factor of 2.95) in the postoperative period. The period needed for recovery in the central retinal thickness is also 1.6 times shorter. The new combination surgery for wet age-related macular degeneration and concurrent chronic peripheral uveitis provides rapid reduction of inflammation in the extreme periphery of the fundus and a 1.5 times faster (as compared to traditional methods) primary restoration of topographic anatomy of the retina in the macular region.

  7. Temporal and spatial predictability of an irrelevant event differently affect detection and memory of items in a visual sequence

    Directory of Open Access Journals (Sweden)

    Junji eOhyama

    2016-02-01

    Full Text Available We examined how the temporal and spatial predictability of a task-irrelevant visual event affects the detection and memory of a visual item embedded in a continuously changing sequence. Participants observed 11 sequentially presented letters, during which a task-irrelevant visual event was either present or absent. Predictabilities of spatial location and temporal position of the event were controlled in 2 × 2 conditions. In the spatially predictable conditions, the event occurred at the same location within the stimulus sequence or at another location, while, in the spatially unpredictable conditions, it occurred at random locations. In the temporally predictable conditions, the event timing was fixed relative to the order of the letters, while in the temporally unpredictable condition, it could not be predicted from the letter order. Participants performed a working memory task and a target detection reaction time task. Memory accuracy was higher for a letter simultaneously presented at the same location as the event in the temporally unpredictable conditions, irrespective of the spatial predictability of the event. On the other hand, the detection reaction times were only faster for a letter simultaneously presented at the same location as the event when the event was both temporally and spatially predictable. Thus, to facilitate ongoing detection processes, an event must be predictable both in space and time, while memory processes are enhanced by temporally unpredictable (i.e., surprising events. Evidently, temporal predictability has differential effects on detection and memory of a visual item embedded in a sequence of images.

  8. The effects of alcohol intoxication on attention and memory for visual scenes.

    Science.gov (United States)

    Harvey, Alistair J; Kneller, Wendy; Campbell, Alison C

    2013-01-01

    This study tests the claim that alcohol intoxication narrows the focus of visual attention on to the more salient features of a visual scene. A group of alcohol intoxicated and sober participants had their eye movements recorded as they encoded a photographic image featuring a central event of either high or low salience. All participants then recalled the details of the image the following day when sober. We sought to determine whether the alcohol group would pay less attention to the peripheral features of the encoded scene than their sober counterparts, whether this effect of attentional narrowing was stronger for the high-salience event than for the low-salience event, and whether it would lead to a corresponding deficit in peripheral recall. Alcohol was found to narrow the focus of foveal attention to the central features of both images but did not facilitate recall from this region. It also reduced the overall amount of information accurately recalled from each scene. These findings demonstrate that the concept of alcohol myopia originally posited to explain the social consequences of intoxication (Steele & Josephs, 1990) may be extended to explain the relative neglect of peripheral information during the processing of visual scenes.

  9. Visualization and automatic detection of defect distribution in GaN atomic structure from sampling Moiré phase.

    Science.gov (United States)

    Wang, Qinghua; Ri, Shien; Tsuda, Hiroshi; Kodera, Masako; Suguro, Kyoichi; Miyashita, Naoto

    2017-09-19

    Quantitative detection of defects in atomic structures is of great significance to evaluating product quality and exploring quality improvement process. In this study, a Fourier transform filtered sampling Moire technique was proposed to visualize and detect defects in atomic arrays in a large field of view. Defect distributions, defect numbers and defect densities could be visually and quantitatively determined from a single atomic structure image at low cost. The effectiveness of the proposed technique was verified from numerical simulations. As an application, the dislocation distributions in a GaN/AlGaN atomic structure in two directions were magnified and displayed in Moire phase maps, and defect locations and densities were detected automatically. The proposed technique is able to provide valuable references to material scientists and engineers by checking the effect of various treatments for defect reduction. © 2017 IOP Publishing Ltd.

  10. Sensory and Motor Peripheral Nerve Function and Longitudinal Changes in Quadriceps Strength

    DEFF Research Database (Denmark)

    Ward, R. E.; Boudreau, R. M.; Caserotti, P.

    2015-01-01

    Background. Poor peripheral nerve function is common in older adults and may be a risk factor for strength decline, although this has not been assessed longitudinally. Methods. We assessed whether sensorimotor peripheral nerve function predicts strength longitudinally in 1,830 participants (age...... was assessed with 10-g and 1.4-g monofilaments and average vibration detection threshold at the toe. Lower-extremity neuropathy symptoms were self-reported. Results. Worse vibration detection threshold predicted 2.4% lower strength in men and worse motor amplitude and two symptoms predicted 2.5% and 8.1% lower...

  11. Measuring temporal summation in visual detection with a single-photon source.

    Science.gov (United States)

    Holmes, Rebecca; Victora, Michelle; Wang, Ranxiao Frances; Kwiat, Paul G

    2017-11-01

    Temporal summation is an important feature of the visual system which combines visual signals that arrive at different times. Previous research estimated complete summation to last for 100ms for stimuli judged "just detectable." We measured the full range of temporal summation for much weaker stimuli using a new paradigm and a novel light source, developed in the field of quantum optics for generating small numbers of photons with precise timing characteristics and reduced variance in photon number. Dark-adapted participants judged whether a light was presented to the left or right of their fixation in each trial. In Experiment 1, stimuli contained a stream of photons delivered at a constant rate while the duration was systematically varied. Accuracy should increase with duration as long as the later photons can be integrated with the proceeding ones into a single signal. The temporal integration window was estimated as the point that performance no longer improved, and was found to be 650ms on average. In Experiment 2, the duration of the visual stimuli was kept short (100ms or photons was varied to explore the efficiency of summation over the integration window compared to Experiment 1. There was some indication that temporal summation remains efficient over the integration window, although there is variation between individuals. The relatively long integration window measured in this study may be relevant to studies of the absolute visual threshold, i.e., tests of single-photon vision, where "single" photons should be separated by greater than the integration window to avoid summation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. A visual test based on a freeware software for quantifying and displaying night-vision disturbances: study in subjects after alcohol consumption.

    Science.gov (United States)

    Castro, José J; Ortiz, Carolina; Pozo, Antonio M; Anera, Rosario G; Soler, Margarita

    2014-05-07

    In this work, we propose the Halo test, a simple visual test based on a freeware software for quantifying and displaying night-vision disturbances perceived by subjects under different experimental conditions, more precisely studying the influence of the alcohol consumption on visual function. In the Halo test, viewed on a monitor, the subject's task consists of detecting luminous peripheral stimuli around a central high-luminance stimulus over a dark background. The test, performed by subjects before and after consuming alcoholic drinks, which deteriorate visual performance, evaluates the influence that alcohol consumption exerts on the visual-discrimination capacity under low illumination conditions. Measurements were made monocularly and binocularly. Pupil size was also measured in both conditions (pre/post). Additionally, we used a double-pass device to measure objectively the optical-quality of the eye and corroborate the results from the Halo test. We found a significant deterioration of the discrimination capacity after alcohol consumption, indicating that the higher the breath-alcohol content, the greater the deterioration of the visual-discrimination capacity. After alcohol intake, the graphical results showed a greater area of undetected peripheral stimuli around the central high-luminance stimulus. An enlargement of the pupil was also observed and the optical quality of the eye was deteriorated after alcohol consumption. A greater influence of halos and other night-vision disturbances were reported with the Halo test after alcohol consumption. The Halo freeware software constitutes a positive contribution for evaluating nighttime visual performance in clinical applications, such as reported here, but also in patients after refractive surgery (where halos are present) or for monitoring (time course) some ocular pathologies under pharmacological treatment.

  13. Molecular Detection of Neuron-Specific ELAV-Like-Positive Cells in the Peripheral Blood of Patients with Small-Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Vito D’Alessandro

    2008-01-01

    Full Text Available Background: n-ELAV (neuronal-Embryonic Lethal, Abnormal Vision-like genes belong to a family codifying for onconeural RNA-binding proteins. Anti-Hu-antibodies (anti-Hu-Ab are typically associated with paraneoplastic encephalomyelitis/sensory neuropathy (PEM/PSN, and low titres of anti-Hu-Ab, were found in newly diagnosed Small Cell Lung Cancer (SCLC. The aim of this study is to develop a sensitive and quantitative molecular real-time PCR assay to detect SCLC cells in peripheral blood (PB through nELAV-like transcripts quantification.

  14. Ultrasonographic evaluation of the iatrogenic peripheral nerve injuries in upper extremity

    International Nuclear Information System (INIS)

    Karabay, Nuri; Toros, Tulgar; Ademoglu, Yalcin; Ada, Sait

    2010-01-01

    The aim of our study is to assess the efficiency of the ultrasonography (US) in the diagnosis of peripheral nerve injury. This study includes nine patients (six radial, one median and two posterior interosseous (PIO) nerves) with peripheral nerve injury diagnosed by clinical and electrophysiological methods in the last 3 years. Preoperatively, an ultrasonographic examination was performed and correlated with physical exam and surgical findings. Five patients, who were diagnosed as peripheral nerve transection by US, underwent surgery. The ultrasonographic findings were concordant with the intraoperative findings. Axonal swelling alone was found in the remaining three patients, who were treated conservatively because of preserved nerve continuity without display of nerve compression. In one patient, we were unable to visualize the nerve due to obesity and soft tissue edema. High-resolution US provide morphological information about the exact location, intensity and extent of the nerve injuries, facilitating the preoperative diagnosis. Thus, US may be a useful method for planning optimal treatment strategy in especially iatrogenic nerve injuries.

  15. Ultrasonographic evaluation of the iatrogenic peripheral nerve injuries in upper extremity

    Energy Technology Data Exchange (ETDEWEB)

    Karabay, Nuri [Department of Radiology, Hand and Microsurgery and Orthopaedics and Traumatology (EMOT) Hospital, 1418 Sok. No: 14 Kahramanlar, 35230 Izmir (Turkey)], E-mail: nurikarabay@gmail.com; Toros, Tulgar [Department of Orthopaedics and Traumatology, Hand and Microsurgery and Orthopaedics and Traumatology (EMOT) Hospital, 1418 Sok. No: 14 Kahramanlar, 35230 Izmir (Turkey)], E-mail: tulgartoros@yahoo.com; Ademoglu, Yalcin [Department of Orthopaedics and Traumatology, Hand and Microsurgery and Orthopaedics and Traumatology (EMOT) Hospital, 1418 Sok. No: 14 Kahramanlar, 35230 Izmir (Turkey)], E-mail: yalcinademoglu@yahoo.com; Ada, Sait [Department of Orthopaedics and Traumatology, Hand and Microsurgery and Orthopaedics and Traumatology (EMOT) Hospital, 1418 Sok. No: 14 Kahramanlar, 35230 Izmir (Turkey)], E-mail: sait_ada@yahoo.com

    2010-02-15

    The aim of our study is to assess the efficiency of the ultrasonography (US) in the diagnosis of peripheral nerve injury. This study includes nine patients (six radial, one median and two posterior interosseous (PIO) nerves) with peripheral nerve injury diagnosed by clinical and electrophysiological methods in the last 3 years. Preoperatively, an ultrasonographic examination was performed and correlated with physical exam and surgical findings. Five patients, who were diagnosed as peripheral nerve transection by US, underwent surgery. The ultrasonographic findings were concordant with the intraoperative findings. Axonal swelling alone was found in the remaining three patients, who were treated conservatively because of preserved nerve continuity without display of nerve compression. In one patient, we were unable to visualize the nerve due to obesity and soft tissue edema. High-resolution US provide morphological information about the exact location, intensity and extent of the nerve injuries, facilitating the preoperative diagnosis. Thus, US may be a useful method for planning optimal treatment strategy in especially iatrogenic nerve injuries.

  16. Seeing diabetes: visual detection of glucose based on the intrinsic peroxidase-like activity of MoS2 nanosheets

    Science.gov (United States)

    Lin, Tianran; Zhong, Liangshuang; Guo, Liangqia; Fu, Fengfu; Chen, Guonan

    2014-09-01

    Molybdenum disulfide (MoS2) has attracted increasing research interest recently due to its unique physical, optical and electrical properties, correlated with its 2D ultrathin atomic-layered structure. Until now, however, great efforts have focused on its applications such as lithium ion batteries, transistors, and hydrogen evolution reactions. Herein, for the first time, MoS2 nanosheets are discovered to possess an intrinsic peroxidase-like activity and can catalytically oxidize 3,3',5,5'-tetramethylbenzidine (TMB) by H2O2 to produce a color reaction. The catalytic activity follows the typical Michaelis-Menten kinetics and is dependent on temperature, pH, H2O2 concentration, and reaction time. Based on this finding, a highly sensitive and selective colorimetric method for H2O2 and glucose detection is developed and applied to detect glucose in serum samples. Moreover, a simple, inexpensive, instrument-free and portable test kit for the visual detection of glucose in normal and diabetic serum samples is constructed by utilizing agarose hydrogel as a visual detection platform.Molybdenum disulfide (MoS2) has attracted increasing research interest recently due to its unique physical, optical and electrical properties, correlated with its 2D ultrathin atomic-layered structure. Until now, however, great efforts have focused on its applications such as lithium ion batteries, transistors, and hydrogen evolution reactions. Herein, for the first time, MoS2 nanosheets are discovered to possess an intrinsic peroxidase-like activity and can catalytically oxidize 3,3',5,5'-tetramethylbenzidine (TMB) by H2O2 to produce a color reaction. The catalytic activity follows the typical Michaelis-Menten kinetics and is dependent on temperature, pH, H2O2 concentration, and reaction time. Based on this finding, a highly sensitive and selective colorimetric method for H2O2 and glucose detection is developed and applied to detect glucose in serum samples. Moreover, a simple, inexpensive

  17. Rapid and sensitive detection of Didymella bryoniae by visual loop-mediated isothermal amplification assay

    Directory of Open Access Journals (Sweden)

    Xiefeng Yao

    2016-08-01

    Full Text Available Didymella bryoniae is a pathogenic fungus that causes gummy stem blight (GSB in Cucurbitaceae crops (e.g. cantaloupe, muskmelon, cucumber, and watermelon. GSB produces lesions on the stems and leaves, and can also be spread by seeds. Here, we developed a rapid, visual, and sensitive loop-mediated amplification (LAMP assay for D. bryoniae detection based on sequence-characterized amplified regions (GenBank accession nos GQ872461 and GQ872462 common to the two random amplification of polymorphic DNA group genotypes (RGI and RGII of D. bryoniae; ideal conditions for detection were optimized for completion in 45 min at 63°C. The sensitivity and specificity of the LAMP assay were further analyzed in comparison with those of a conventional polymerase chain reaction (PCR. The sensitivity of the LAMP assay was 1000-fold higher than that of conventional PCR with a detection limit of 0.1 fg μL−1 of targeted DNA. The LAMP assay could be accomplished in about 45 min, with the results visible to the naked eye. The assay showed high specificity in discriminating all D. bryoniae isolates from seven other fungal pathogens that occur in Cucurbitaceae crops. The LAMP assay also detected D. bryoniae infection in young muskmelon leaves with suspected early symptoms of GSB disease. Hence, the technique has great potential for developing rapid and sensitive visual detection methods for the D. bryoniae pathogen in crops and seeds. This method has potential application in early prediction of disease and reducing the risk of epidemics.

  18. Clinical indications for high-resolution MRI diagnostics of the peripheral nervous system; Klinische Indikationen hochaufloesender MRT-Diagnostik des peripheren Nervensystems

    Energy Technology Data Exchange (ETDEWEB)

    Godel, T. [Universitaetsklinikum Heidelberg, Abteilung fuer Neuroradiologie, Heidelberg (Germany); Weiler, M. [Universitaetsklinikum Heidelberg, Neurologische Klinik, Heidelberg (Germany)

    2017-03-15

    Peripheral neuropathies are common and diagnostically often challenging disorders. Difficulties particularly exist in lesion localization and recognition of complex spatial lesion patterns. Medical history taking, neurological examination, neurophysiological tests and nerve ultrasonography represent the gold standard in the diagnosis of peripheral nerve lesions but have known methodical limitations. The use of 3 Tesla magnetic resonance neurography (MRN) is an additional diagnostic imaging tool recently developed for the high-resolution visualization of long segments of peripheral nerves. Reasonable clinical indications for MRN are exemplarily presented. Using MRN a direct visualization and thus precise localization of focal and non-focal peripheral nerve lesions of various origins can be achieved with high spatial resolution down to the anatomical level of nerve fascicles. Using MRN large anatomical areas of the peripheral nervous system (PNS) can be covered in a single examination session, spatial nerve lesion patterns can be evaluated and the underlying causes can often be detected. The MRN is a valuable supplement to the diagnostic work-up of the PNS, especially in cases that cannot be clarified with standard diagnostic methods. Evaluation of the spatial nerve lesion pattern gives additional information on the origin of the underlying disease. Reasonable indications for MRN are the assessment of proximal nerve structures including the brachial and lumbosacral nerve plexi, the clarification of inconclusive diagnostic results, preoperative, postoperative and posttraumatic assessments, the identification of fascicular nerve lesions and the differential diagnosis of an alleged somatoform disorder. (orig.) [German] Periphere Neuropathien sind haeufige und diagnostisch mitunter anspruchsvolle Erkrankungen. Schwierigkeiten bestehen v. a. bei der Laesionslokalisation und Erkennung komplexer Laesionsmuster. Anamnese, klinisch-neurologische Untersuchung

  19. Information theoretic analysis of edge detection in visual communication

    Science.gov (United States)

    Jiang, Bo; Rahman, Zia-ur

    2010-08-01

    Generally, the designs of digital image processing algorithms and image gathering devices remain separate. Consequently, the performance of digital image processing algorithms is evaluated without taking into account the artifacts introduced into the process by the image gathering process. However, experiments show that the image gathering process profoundly impacts the performance of digital image processing and the quality of the resulting images. Huck et al. proposed one definitive theoretic analysis of visual communication channels, where the different parts, such as image gathering, processing, and display, are assessed in an integrated manner using Shannon's information theory. In this paper, we perform an end-to-end information theory based system analysis to assess edge detection methods. We evaluate the performance of the different algorithms as a function of the characteristics of the scene, and the parameters, such as sampling, additive noise etc., that define the image gathering system. The edge detection algorithm is regarded to have high performance only if the information rate from the scene to the edge approaches the maximum possible. This goal can be achieved only by jointly optimizing all processes. People generally use subjective judgment to compare different edge detection methods. There is not a common tool that can be used to evaluate the performance of the different algorithms, and to give people a guide for selecting the best algorithm for a given system or scene. Our information-theoretic assessment becomes this new tool to which allows us to compare the different edge detection operators in a common environment.

  20. Evaluation of age and peripheral vascular disease as risk factors for ...

    African Journals Online (AJOL)

    Results: Among the 120 diabetic participants, peripheral vascular disease (PVD) was detected only in those aged 50 years and above and all the three diagnostic methods detected PVD increasingly with advancing age. Clinical criteria detected PVD in 4.7% of those aged 50-59 years and 26.3% of those aged .70years.

  1. Clinical performance of two visual scoring systems in detecting and assessing activity status of occlusal caries in primary teeth

    DEFF Research Database (Denmark)

    Braga, M M; Ekstrand, K R; Martignon, S

    2010-01-01

    This study aimed to compare the clinical performance of two sets of visual scoring criteria for detecting caries severity and assessing caries activity status in occlusal surfaces. Two visual scoring systems--the Nyvad criteria (NY) and the ICDAS-II including an adjunct system for lesion activity...

  2. Symmetric visualization of the femoral heads in reticuloendothelial bone marrow scanning in adults

    Energy Technology Data Exchange (ETDEWEB)

    Munz, D L; Hoer, G

    1983-03-01

    Two hundred and twenty seven consecutive patients of either sex aged 15-84 suffering from various benign and malignant disorders were studied by sup(99m)Tc-HSA-MM reticuloendothelial bone marrow scintigraphy. In all patients, symmetric findings concerning visualization or nonvisualization of the femoral heads could be seen. Femoral heads were clearly visualized in 48%, nonvisualized in 43%, and equivocally visualized in 9%. In patients with clearly visualized femoral heads, the bone marrow showed peripheral extension in 81%, whereas in patients with nonvisualized femoral heads, bone marrow extension was observed in only 42%. There was a correlation between the degree of bone marrow extension and the ability to visualize femoral heads. There was no obvious difference between males and females, nor patients with various diseases or treatments, amongst nor between different age groups. Two hypotheses are suggested to explain the correspondence between presence of bone marrow tissue in the femoral heads and peripheral extension of the bone marrow organ. Nonvisualization of the femoral heads alone is insufficient to establish the diagnosis of avascular necrosis.

  3. Forensic differentiation between peripheral and menstrual blood in cases of alleged sexual assault-validating an immunochromatographic multiplex assay for simultaneous detection of human hemoglobin and D-dimer.

    Science.gov (United States)

    Holtkötter, Hannah; Dias Filho, Claudemir Rodrigues; Schwender, Kristina; Stadler, Christian; Vennemann, Marielle; Pacheco, Ana Claudia; Roca, Gabriela

    2018-05-01

    Sexual assault is a serious offense and identification of body fluids originating from sexual activity has been a crucial aspect of forensic investigations for a long time. While reliable tests for the detection of semen and saliva have been successfully implemented into forensic laboratories, the detection of other body fluids, such as vaginal or menstrual fluid, is more challenging. Especially, the discrimination between peripheral and menstrual blood can be highly relevant for police investigations because it provides potential evidence regarding the issue of consent. We report the forensic validation of an immunochromatographic test that allows for such discrimination in forensic stains, the SERATEC PMB test, and its performance on real casework samples. The PMB test is a duplex test combining human hemoglobin and D-dimer detection and was developed for the identification of blood and menstrual fluid, both at the crime scene and in the laboratory. The results of this study showed that the duplex D-dimer/hemoglobin assay reliably detects the presence of human hemoglobin and identifies samples containing menstrual fluid by detecting the presence of D-dimers. The method distinguished between menstrual and peripheral blood in a swab from a historical artifact and in real casework samples of alleged sexual assaults. Results show that the development of the new duplex test is a substantial progress towards analyzing and interpreting evidence from sexual assault cases.

  4. [Impact of hypoglycemic episodes on nerves conduction and auditory and visual evoked potentials in children with type 1 diabetes].

    Science.gov (United States)

    Wysocka-Mincewicz, Marta; Trippenbach-Dulska, Hanna; Emeryk-Szajewska, Barbara; Zakrzewska-Pniewska, Beata; Kochanek, Krzysztof; Pańkowska, Ewa

    2007-01-01

    Hypoglycemia is an acute disturbance of energy, especially impacting the central nervous system, but direct influence on peripheral nervous function is not detected. The aim of the study was to establish the influence of hypoglycemic moderate and severe episodes on the function of peripheral nerves, hearing and visual pathway. 97 children with type 1 diabetes (mean age 15.4+/-2.16 years, mean duration of diabetes 8.11+/-2.9 years, mean HbA1c 8,58+/-1.06%), at least 10 years old and with at least 3 years duration of diabetes, were included to study. Nerve conduction studies, visual (VEP) and auditory (ABR) evoked potentials were performed with standard surface stimulating and recording techniques. Moderate hypoglycemic episodes were defined as events of low glycemia requiring help of another person but without loss of consciousness and/or convulsions but recurrent frequently in at least one year. Severe hypoglycemia was defined as events with loss of consciousness and/or convulsions. Univariate ANOVA tests of significance or H Kruskal-Wallis test were used, depending on normality of distribution. The subgroups with a history of hypoglycemic episodes had significant delay in all conduction parameters in the sural nerve (amplitude pwave III latency and interval I-III in subgroups with episodes of hypoglycemia (pwave III and interval I-III. Frequent moderate hypoglycemic episodes were strong risk factors for damage of the peripheral and central nervous systems, comparable with impact of several severe hypoglycemias.

  5. Bilateral foveal retinoschisis accompanying unilateral peripheral retinoschisis

    Directory of Open Access Journals (Sweden)

    Nilufer Kocak

    2014-01-01

    Full Text Available X-linked juvenile retinoschisis is a rare hereditary retinal disease characterized by a tangential splitting of the neurosensory retina which may cause early-onset visual impairment. Existence of the retinal neurosensory layer splitting on cross-sectional images of optical coherance tomography (OCT and the absence of leakage on fluorescein angiography (FA help confirming the diagnosis. Such diagnostic tests are also helpful in determining the management of the disease. However, most of the retinoschisis cavities remain stable and rarely extend to the posterior pole, many authors suggest laser prophylaxis to avoid the potential risk of retinal detachment due to holes in the outer retinal layer. Herein, we report a case with bilateral foveal retinoschisis accompanying unilateral peripheral retinoschisis who was evaluated with detailed ophthalmologic examination. Visual acuity, fundoscopy, OCT, and FA remained stable in the second year of follow-up after prophylactic argon laser treatment.

  6. Self-construal priming selectively modulates the scope of visual attention

    Directory of Open Access Journals (Sweden)

    Zhuozhuo eLiu

    2015-09-01

    Full Text Available Self-concept is one of the major factors to explain the cultural differences between East Asians and Westerners. In the field of visual attention, most studies have focused on the modulation of visual spatial-based attention, whereas possible influences of culture or self-concept on other types of visual attention remain largely unexplored. The present study investigated the possible modulation of visual feature-based attention by self-concept, using a within-group self-construal priming design. The experiment paradigm employed visual stimuli consisted of two intermixing random dot clouds presented in the focal visual field with red and green colors. After primed with an interdependent, independent or neutral self-construal, the participants were instructed to attend to one of the focally presented dot cloud and respond to occasional luminance decrement events of the attended dot cloud. The detection of the focal events was found to be significantly faster when exogenously cued by a peripheral dot cloud of either the same or different colors as the attended focal dot cloud (congruent / incongruent, compared to the uncued condition. More importantly, the self-construal priming took effect only on the reaction time (RT differences between the congruent and incongruent cued conditions: the participants responded much slower to incongruent cued events than congruent cued events under interdependent self-construal priming, while the RT difference was significantly smaller under independent self-construal priming. A closer look on the results suggests that the attention scope is selectively modulated by self-construal priming, and the modulation is mainly reflected by varying the degree of suppression on the processing of the incongruent contextual stimuli that do not share visual features with the focal object. Our findings provide new evidences that could possibly extend the current understanding on the cultural influence on visual attention.

  7. Foveal and peripheral fields of vision influences perceptual skill in anticipating opponents' attacking position in volleyball.

    Science.gov (United States)

    Schorer, Jörg; Rienhoff, Rebecca; Fischer, Lennart; Baker, Joseph

    2013-09-01

    The importance of perceptual-cognitive expertise in sport has been repeatedly demonstrated. In this study we examined the role of different sources of visual information (i.e., foveal versus peripheral) in anticipating volleyball attack positions. Expert (n = 11), advanced (n = 13) and novice (n = 16) players completed an anticipation task that involved predicting the location of volleyball attacks. Video clips of volleyball attacks (n = 72) were spatially and temporally occluded to provide varying amounts of information to the participant. In addition, participants viewed the attacks under three visual conditions: full vision, foveal vision only, and peripheral vision only. Analysis of variance revealed significant between group differences in prediction accuracy with higher skilled players performing better than lower skilled players. Additionally, we found significant differences between temporal and spatial occlusion conditions. Both of those factors interacted separately, but not combined with expertise. Importantly, for experts the sum of both fields of vision was superior to either source in isolation. Our results suggest different sources of visual information work collectively to facilitate expert anticipation in time-constrained sports and reinforce the complexity of expert perception.

  8. New sonographic measures of peripheral nerves: a tool for the diagnosis of peripheral nerve involvement in leprosy

    Directory of Open Access Journals (Sweden)

    Marco Andrey Cipriani Frade

    2013-05-01

    Full Text Available To evaluate ultrasonographic (US cross-sectional areas (CSAs of peripheral nerves, indexes of the differences between CSAs at the same point (∆CSAs and between tunnel (T and pre-tunnel (PT ulnar CSAs (∆TPTs in leprosy patients (LPs and healthy volunteers (HVs. Seventy-seven LPs and 49 HVs underwent bilateral US at PT and T ulnar points, as well as along the median (M and common fibular (CF nerves, to calculate the CSAs, ∆CSAs and ∆TPTs. The CSA values in HVs were lower than those in LPs (p 80% and ∆TPT had the highest specificity (> 90%. New sonographic peripheral nerve measurements (∆CSAs and ∆TPT provide an important methodological improvement in the detection of leprosy neuropathy.

  9. Common constraints limit Korean and English character recognition in peripheral vision.

    Science.gov (United States)

    He, Yingchen; Kwon, MiYoung; Legge, Gordon E

    2018-01-01

    The visual span refers to the number of adjacent characters that can be recognized in a single glance. It is viewed as a sensory bottleneck in reading for both normal and clinical populations. In peripheral vision, the visual span for English characters can be enlarged after training with a letter-recognition task. Here, we examined the transfer of training from Korean to English characters for a group of bilingual Korean native speakers. In the pre- and posttests, we measured visual spans for Korean characters and English letters. Training (1.5 hours × 4 days) consisted of repetitive visual-span measurements for Korean trigrams (strings of three characters). Our training enlarged the visual spans for Korean single characters and trigrams, and the benefit transferred to untrained English symbols. The improvement was largely due to a reduction of within-character and between-character crowding in Korean recognition, as well as between-letter crowding in English recognition. We also found a negative correlation between the size of the visual span and the average pattern complexity of the symbol set. Together, our results showed that the visual span is limited by common sensory (crowding) and physical (pattern complexity) factors regardless of the language script, providing evidence that the visual span reflects a universal bottleneck for text recognition.

  10. Airport object extraction based on visual attention mechanism and parallel line detection

    Science.gov (United States)

    Lv, Jing; Lv, Wen; Zhang, Libao

    2017-10-01

    Target extraction is one of the important aspects in remote sensing image analysis and processing, which has wide applications in images compression, target tracking, target recognition and change detection. Among different targets, airport has attracted more and more attention due to its significance in military and civilian. In this paper, we propose a novel and reliable airport object extraction model combining visual attention mechanism and parallel line detection algorithm. First, a novel saliency analysis model for remote sensing images with airport region is proposed to complete statistical saliency feature analysis. The proposed model can precisely extract the most salient region and preferably suppress the background interference. Then, the prior geometric knowledge is analyzed and airport runways contained two parallel lines with similar length are detected efficiently. Finally, we use the improved Otsu threshold segmentation method to segment and extract the airport regions from the salient map of remote sensing images. The experimental results demonstrate that the proposed model outperforms existing saliency analysis models and shows good performance in the detection of the airport.

  11. Robust Detection and Visualization of Jet-Stream Core Lines in Atmospheric Flow.

    Science.gov (United States)

    Kern, Michael; Hewson, Tim; Sadlo, Filip; Westermann, Rudiger; Rautenhaus, Marc

    2018-01-01

    Jet-streams, their core lines and their role in atmospheric dynamics have been subject to considerable meteorological research since the first half of the twentieth century. Yet, until today no consistent automated feature detection approach has been proposed to identify jet-stream core lines from 3D wind fields. Such 3D core lines can facilitate meteorological analyses previously not possible. Although jet-stream cores can be manually analyzed by meteorologists in 2D as height ridges in the wind speed field, to the best of our knowledge no automated ridge detection approach has been applied to jet-stream core detection. In this work, we -a team of visualization scientists and meteorologists-propose a method that exploits directional information in the wind field to extract core lines in a robust and numerically less involved manner than traditional 3D ridge detection. For the first time, we apply the extracted 3D core lines to meteorological analysis, considering real-world case studies and demonstrating our method's benefits for weather forecasting and meteorological research.

  12. Voice activity detection using audio-visual information

    DEFF Research Database (Denmark)

    Petsatodis, Theodore; Pnevmatikakis, Aristodemos; Boukis, Christos

    2009-01-01

    An audio-visual voice activity detector that uses sensors positioned distantly from the speaker is presented. Its constituting unimodal detectors are based on the modeling of the temporal variation of audio and visual features using Hidden Markov Models; their outcomes are fused using a post...

  13. Simple Radiowave-Based Method For Measuring Peripheral Blood Flow Project

    Science.gov (United States)

    Oliva-Buisson, Yvette J.

    2014-01-01

    Project objective is to design small radio frequency based flow probes for the measurement of blood flow velocity in peripheral arteries such as the femoral artery and middle cerebral artery. The result will be the technological capability to measure peripheral blood flow rates and flow changes during various environmental stressors such as microgravity without contact to the individual being monitored. This technology may also lead to an easier method of detecting venous gas emboli during extravehicular activities.

  14. The Charles F. Prentice Award Lecture 2010: A Case for Peripheral Optical Treatment Strategies for Myopia

    Science.gov (United States)

    Smith, Earl L.

    2011-01-01

    It is well established that refractive development is regulated by visual feedback. However, most optical treatment strategies designed to reduce myopia progression have not produced the desired results, primarily because some of our assumptions concerning the operating characteristics of the vision-dependent mechanisms that regulate refractive development have been incorrect. In particular, because of the prominence of central vision in primates, it has generally been assumed that signals from the fovea determine the effects of vision on refractive development. However, experiments in laboratory animals demonstrate that ocular growth and emmetropization are mediated by local retinal mechanisms and that foveal vision is not essential for many vision-dependent aspects of refractive development. On the other hand, the peripheral retina, in isolation, can effectively regulate emmetropization and mediate many of the effects of vision on the eye’s refractive status. Moreover, when there are conflicting visual signals between the fovea and the periphery, peripheral vision can dominate refractive development. The overall pattern of results suggests that optical treatment strategies for myopia that take into account the effects of peripheral vision are likely to be more successful than strategies that effectively manipulate only central vision. PMID:21747306

  15. Irrelevant Auditory and Visual Events Induce a Visual Attentional Blink

    NARCIS (Netherlands)

    Van der Burg, Erik; Nieuwenstein, Mark R.; Theeuwes, Jan; Olivers, Christian N. L.

    2013-01-01

    In the present study we investigated whether a task-irrelevant distractor can induce a visual attentional blink pattern. Participants were asked to detect only a visual target letter (A, B, or C) and to ignore the preceding auditory, visual, or audiovisual distractor. An attentional blink was

  16. Nerve ultrasound shows subclinical peripheral nerve involvement in neurofibromatosis type 2.

    Science.gov (United States)

    Telleman, Johan A; Stellingwerff, Menno D; Brekelmans, Geert J; Visser, Leo H

    2018-02-01

    Neurofibromatosis type 2 (NF2) is mainly associated with central nervous system (CNS) tumors. Peripheral nerve involvement is described in symptomatic patients, but evidence of subclinical peripheral nerve involvement is scarce. We conducted a cross-sectional pilot study in 2 asymptomatic and 3 minimally symptomatic patients with NF2 to detect subclinical peripheral nerve involvement. Patients underwent clinical examination, nerve conduction studies (NCS), and high-resolution ultrasonography (HRUS). A total of 30 schwannomas were found, divided over 20 nerve segments (33.9% of all investigated nerve segments). All patients had at least 1 schwannoma. Schwannomas were identified with HRUS in 37% of clinically unaffected nerve segments and 50% of nerve segments with normal NCS findings. HRUS shows frequent subclinical peripheral nerve involvement in NF2. Clinicians should consider peripheral nerve involvement as a cause of weakness and sensory loss in the extremities in patients with this disease. Muscle Nerve 57: 312-316, 2018. © 2017 Wiley Periodicals, Inc.

  17. Processing of unattended facial emotions: a visual mismatch negativity study.

    Science.gov (United States)

    Stefanics, Gábor; Csukly, Gábor; Komlósi, Sarolta; Czobor, Pál; Czigler, István

    2012-02-01

    Facial emotions express our internal states and are fundamental in social interactions. Here we explore whether the repetition of unattended facial emotions builds up a predictive representation of frequently encountered emotions in the visual system. Participants (n=24) were presented peripherally with facial stimuli expressing emotions while they performed a visual detection task presented in the center of the visual field. Facial stimuli consisted of four faces of different identity, but expressed the same emotion (happy or fearful). Facial stimuli were presented in blocks of oddball sequence (standard emotion: p=0.9, deviant emotion: p=0.1). Event-related potentials (ERPs) to the same emotions were compared when the emotions were deviant and standard, respectively. We found visual mismatch negativity (vMMN) responses to unattended deviant emotions in the 170-360 ms post-stimulus range over bilateral occipito-temporal sites. Our results demonstrate that information about the emotional content of unattended faces presented at the periphery of the visual field is rapidly processed and stored in a predictive memory representation by the visual system. We also found evidence that differential processing of deviant fearful faces starts already at 70-120 ms after stimulus onset. This finding shows a 'negativity bias' under unattended conditions. Differential processing of fearful deviants were more pronounced in the right hemisphere in the 195-275 ms and 360-390 ms intervals, whereas processing of happy deviants evoked larger differential response in the left hemisphere in the 360-390 ms range, indicating differential hemispheric specialization for automatic processing of positive and negative affect. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. Higher-order neural processing tunes motion neurons to visual ecology in three species of hawkmoths.

    Science.gov (United States)

    Stöckl, A L; O'Carroll, D; Warrant, E J

    2017-06-28

    To sample information optimally, sensory systems must adapt to the ecological demands of each animal species. These adaptations can occur peripherally, in the anatomical structures of sensory organs and their receptors; and centrally, as higher-order neural processing in the brain. While a rich body of investigations has focused on peripheral adaptations, our understanding is sparse when it comes to central mechanisms. We quantified how peripheral adaptations in the eyes, and central adaptations in the wide-field motion vision system, set the trade-off between resolution and sensitivity in three species of hawkmoths active at very different light levels: nocturnal Deilephila elpenor, crepuscular Manduca sexta , and diurnal Macroglossum stellatarum. Using optical measurements and physiological recordings from the photoreceptors and wide-field motion neurons in the lobula complex, we demonstrate that all three species use spatial and temporal summation to improve visual performance in dim light. The diurnal Macroglossum relies least on summation, but can only see at brighter intensities. Manduca, with large sensitive eyes, relies less on neural summation than the smaller eyed Deilephila , but both species attain similar visual performance at nocturnal light levels. Our results reveal how the visual systems of these three hawkmoth species are intimately matched to their visual ecologies. © 2017 The Author(s).

  19. Visual Outcome after Laser Photocoagulation for Stage 4 ...

    African Journals Online (AJOL)

    Objective: The objectives of this research is to evaluate the visual outcome after peripheral laser photo-coagulation for Goldberg stage-4 proliferative sickle cell retinopathy patients seen in Eye Foundation Hospital Lagos between January and December 2002. Methodology: A hospital-based retrospective case review study ...

  20. VISUAL OUTCOME FOLLOWING PANRETINAL PHOTOCOAGULATION IN PROLIFERATIVE DIABETIC RETINOPATHY

    Directory of Open Access Journals (Sweden)

    Nellaye Mani Sindhu

    2018-01-01

    Full Text Available BACKGROUND Diabetes mellitus can be called as a noninfectious pandemic and the incidence of diabetic retinopathy is also uncontrollable. This vision-threatening complication can be treated by early diagnosis and effective treatment like panretinal photocoagulation. The aim of the study is to evaluate the effect of panretinal photocoagulation on visual acuity, colour vision, contrast sensitivity and severity of visual field changes. MATERIALS AND METHODS Prospective study of visual outcome following panretinal photocoagulation in patients with proliferative diabetic retinopathy conducted in Retina Clinic, RIO, Trivandrum, during the time period one year from April 2008. Inclusion Criteria- Eyes with proliferative diabetic retinopathy, visual acuity better than or equal to 6/60, a follow up of at least 6 months after panretinal photocoagulation. Exclusion Criteria- Eyes with cataractous changes in the lens, eyes, which would be undergoing or have undergone focal photocoagulation eyes, which undergone barrage or sectoral retinal photocoagulation, patients with colour blindness, eyes with vitreous haemorrhage and macular preretinal haemorrhage, glaucomatous patients with peripheral field loss. RESULTS The mean age of the patients was 52 years. Male patients (30 outnumbered the female patients (23. Mean duration of diabetes was 14.42 years. Though, there is a statistically significant reduction in visual acuity in the first followup, which was improved and stabilised by 6 months. There is a statistically significant reduction in the contrast sensitivity, which was stabilised after 3 months. Only, 9.5% patients had peripheral constrictions of visual field and no significant change in the colour vision. CONCLUSION We recommend panretinal photocoagulation for all patients with proliferative diabetic retinopathy.

  1. Visual detection of the human metapneumovirus using reverse transcription loop-mediated isothermal amplification with hydroxynaphthol blue dye

    Directory of Open Access Journals (Sweden)

    Wang Xiang

    2012-07-01

    Full Text Available Abstract Background Human metapneumovirus (hMPV is a major cause of acute respiratory infections ranging from wheezing to bronchiolitis and pneumonia in children worldwide. The objective of this study is to develop a visual reverse transcription loop-mediated isothermal amplification (RT-LAMP assay for the detection of hMPV and applied to the clinical samples. Results In this study, visual RT-LAMP assay for hMPV was performed in one step with the addition of hydroxynaphthol blue (HNB, and were used to detect respiratory samples. Six primers, including two outer primers (F3 and B3, two inner primers (FIP, BIP and two loop primers (LF and LB, were designed for hMPV N gene by the online software. Moreover, the RT-LAMP assay showed good specificity and no cross-reactivity was observed with human rhinovirus (HRV, human respiratory syncytial Virus (RSV, or influenza virus A/PR/8/34 (H1N1. The detection limit of the RT-LAMP assay was approximately ten viral RNA copies, lower than that of traditional reverse transcriptase polymerase chain reaction (RT-PCR 100 RNA copies. In the 176 nasopharyngeal samples, 23 (13.1% were conformed as hMPV positive by RT-LAMP, but 18 (10.2% positive by RT-PCR. Conclusion Compared with conventional RT-PCR, the visual hMPV RT-LAMP assay performed well in the aspect of detect time, sensitivity, specificity and visibility. It is anticipated that the RT-LAMP will be used for clinical tests in hospital or field testing during outbreaks and in emergency.

  2. Transitions between central and peripheral vision create spatial/temporal distortions: a hypothesis concerning the perceived break of the curveball.

    Directory of Open Access Journals (Sweden)

    Arthur Shapiro

    2010-10-01

    Full Text Available The human visual system does not treat all parts of an image equally: the central segments of an image, which fall on the fovea, are processed with a higher resolution than the segments that fall in the visual periphery. Even though the differences between foveal and peripheral resolution are large, these differences do not usually disrupt our perception of seamless visual space. Here we examine a motion stimulus in which the shift from foveal to peripheral viewing creates a dramatic spatial/temporal discontinuity.The stimulus consists of a descending disk (global motion with an internal moving grating (local motion. When observers view the disk centrally, they perceive both global and local motion (i.e., observers see the disk's vertical descent and the internal spinning. When observers view the disk peripherally, the internal portion appears stationary, and the disk appears to descend at an angle. The angle of perceived descent increases as the observer views the stimulus from further in the periphery. We examine the first- and second-order information content in the display with the use of a three-dimensional Fourier analysis and show how our results can be used to describe perceived spatial/temporal discontinuities in real-world situations.The perceived shift of the disk's direction in the periphery is consistent with a model in which foveal processing separates first- and second-order motion information while peripheral processing integrates first- and second-order motion information. We argue that the perceived distortion may influence real-world visual observations. To this end, we present a hypothesis and analysis of the perception of the curveball and rising fastball in the sport of baseball. The curveball is a physically measurable phenomenon: the imbalance of forces created by the ball's spin causes the ball to deviate from a straight line and to follow a smooth parabolic path. However, the curveball is also a perceptual puzzle

  3. Transitions between central and peripheral vision create spatial/temporal distortions: a hypothesis concerning the perceived break of the curveball.

    Science.gov (United States)

    Shapiro, Arthur; Lu, Zhong-Lin; Huang, Chang-Bing; Knight, Emily; Ennis, Robert

    2010-10-13

    The human visual system does not treat all parts of an image equally: the central segments of an image, which fall on the fovea, are processed with a higher resolution than the segments that fall in the visual periphery. Even though the differences between foveal and peripheral resolution are large, these differences do not usually disrupt our perception of seamless visual space. Here we examine a motion stimulus in which the shift from foveal to peripheral viewing creates a dramatic spatial/temporal discontinuity. The stimulus consists of a descending disk (global motion) with an internal moving grating (local motion). When observers view the disk centrally, they perceive both global and local motion (i.e., observers see the disk's vertical descent and the internal spinning). When observers view the disk peripherally, the internal portion appears stationary, and the disk appears to descend at an angle. The angle of perceived descent increases as the observer views the stimulus from further in the periphery. We examine the first- and second-order information content in the display with the use of a three-dimensional Fourier analysis and show how our results can be used to describe perceived spatial/temporal discontinuities in real-world situations. The perceived shift of the disk's direction in the periphery is consistent with a model in which foveal processing separates first- and second-order motion information while peripheral processing integrates first- and second-order motion information. We argue that the perceived distortion may influence real-world visual observations. To this end, we present a hypothesis and analysis of the perception of the curveball and rising fastball in the sport of baseball. The curveball is a physically measurable phenomenon: the imbalance of forces created by the ball's spin causes the ball to deviate from a straight line and to follow a smooth parabolic path. However, the curveball is also a perceptual puzzle because batters often

  4. Imaging of a glioma using peripheral benzodiazepine receptor ligands

    Energy Technology Data Exchange (ETDEWEB)

    Starosta-Rubinstein, S.; Ciliax, B.J.; Penney, J.B.; McKeever, P.; Young, A.B.

    1987-02-01

    Two types of benzodiazepine receptors have been demonstrated in mammalian tissues, one which is localized on neuronal elements in brain and the other, on glial cells and in peripheral tissues such as kidney. In vivo administration of /sup 3/H-labeled PK 11195 (1-(2-chlorophenyl-N-methyl-N-(1-methylpropyl)-3-isoquinoline carboxamide) or (/sup 3/H)flunitrazepam with 5 mg of clonazepam per kg to rats with intracranial C6 gliomas resulted in high levels of tritiated-drug binding to the tumor as shown by quantitative autoradiography. Pharmacological studies indicated that the bound drugs labeled the peripheral benzodiazepine binding site. Binding to the peripheral benzodiazepine site was confirmed primarily to malignant cells with little binding to adjacent normal brain tissue or to necrotic tissue. Tumor cell binding was completely inhibited by preadministration of the peripheral benzodiazepine blocking agent PK 11195 at 5 mg/kg. The centrally selective benzodiazepine ligand clonazepam had no effect on PK 11195 binding to the tumor cells. When binding to other tumor cell lines grown in nude mice and nude athymic rats was evaluated, little or no peripheral benzodiazepine binding was detected on human pheochromocytoma (RN1) and neuroblastoma (SK-N-MC, SK-N-SH) tumor cells, respectively. However, high densities of peripheral benzodiazepine binding sites were observed on tumors derived from a human glioma cell line (ATCC HTB 14, U-87 MG). The presence of high concentrations of specific peripheral benzodiazepine receptors on glial tumors suggests that human primary central nervous system tumors could be imaged and diagnosed using peripheral benzodiazepine ligands labeled with positron- or gamma-emitting isotopes.

  5. A Visual Analytics Approach for Detecting and Understanding Anomalous Resident Behaviors in Smart Healthcare

    Directory of Open Access Journals (Sweden)

    Zhifang Liao

    2017-03-01

    Full Text Available With the development of science and technology, it is possible to analyze residents’ daily behaviors for the purpose of smart healthcare in the smart home environment. Many researchers have begun to detect residents’ anomalous behaviors and assess their physical condition, but these approaches used by the researchers are often caught in plight caused by a lack of ground truth, one-sided analysis of behavior, and difficulty of understanding behaviors. In this paper, we put forward a smart home visual analysis system (SHVis to help analysts detect and comprehend unusual behaviors of residents, and predict the health information intelligently. Firstly, the system classifies daily activities recorded by sensor devices in smart home environment into different categories, and discovers unusual behavior patterns of residents living in this environment by using various characteristics extracted from those activities and appropriate unsupervised anomaly detection algorithm. Secondly, on the basis of figuring out the residents’ anomaly degree of every date, we explore the daily behavior patterns and details with the help of several visualization views, and compare and analyze residents’ activities of various dates to find the reasons why residents act unusually. In the case study of this paper, we analyze residents’ behaviors that happened over two months and find unusual indoor behaviors and give health advice to the residents.

  6. Emphysema progression is visually detectable in low-dose CT in continuous but not in former smokers

    DEFF Research Database (Denmark)

    Wille, Mathilde Marie Winkler; Thomsen, Laura H.; Dirksen, Asger

    2014-01-01

    prevalence and grade of emphysema in late CT examinations). Significant progression in emphysema was seen in continuous smokers, but not in former smokers. Agreement on centrilobular emphysema subtype was substantial; agreement on paraseptal subtype, moderate. Agreement on panlobular and mixed subtypes......: Visual scoring of chest CT is able to characterise the presence, pattern, and progression of early emphysema. Continuous smokers progress; former smokers do not. KEY POINTS: • Substantial interobserver consistency in determining early-stage emphysema in low-dose CT. • Longitudinal analyses show clear...... time-trends for emphysema presence and grading. • For continuous smokers, progression of emphysema was seen in all lung zones. • For former smokers, progression of emphysema was undetectable by visual assessment. • Onset and progression of interstitial abnormalities are visually detectable....

  7. Respiratory Syncytial Virus (RSV RNA loads in peripheral blood correlates with disease severity in mice

    Directory of Open Access Journals (Sweden)

    Torres Juan

    2010-09-01

    Full Text Available Abstract Background Respiratory Syncytial Virus (RSV infection is usually restricted to the respiratory epithelium. Few studies have documented the presence of RSV in the systemic circulation, however there is no consistent information whether virus detection in the blood correlates with disease severity. Methods Balb/c mice were inoculated with live RSV, heat-inactivated RSV or medium. A subset of RSV-infected mice was treated with anti-RSV antibody 72 h post-inoculation. RSV RNA loads were measured by PCR in peripheral blood from day 1-21 post-inoculation and were correlated with upper and lower respiratory tract viral loads, the systemic cytokine response, lung inflammation and pulmonary function. Immunohistochemical staining was used to define the localization of RSV antigens in the respiratory tract and peripheral blood. Results RSV RNA loads were detected in peripheral blood from day 1 to 14 post-inoculation, peaked on day 5 and significantly correlated with nasal and lung RSV loads, airway obstruction, and blood CCL2 and CXCL1 expression. Treatment with anti-RSV antibody reduced blood RSV RNA loads and improved airway obstruction. Immunostaining identified RSV antigens in alveolar macrophages and peripheral blood monocytes. Conclusions RSV RNA was detected in peripheral blood upon infection with live RSV, followed a time-course parallel to viral loads assessed in the respiratory tract and was significantly correlated with RSV-induced airway disease.

  8. The role of serum methylglyoxal on diabetic peripheral and cardiovascular autonomic neuropathy

    DEFF Research Database (Denmark)

    Hansen, C.S.; Jensen, T.M.; Jensen, J.S.

    2015-01-01

    AIMS: Cardiovascular autonomic neuropathy and diabetic peripheral neuropathy are common diabetic complications and independent predictors of cardiovascular disease. The glucose metabolite methylglyoxal has been suggested to play a causal role in the pathogeneses of diabetic peripheral neuropathy...... and possibly diabetic cardiovascular autonomic neuropathy. The aim of this study was to investigate the cross-sectional association between serum methylglyoxal and diabetic peripheral neuropathy and cardiovascular autonomic neuropathy in a subset of patients in the ADDITION-Denmark study with short-term screen......-detected Type 2 diabetes (duration ~ 5.8 years). METHODS: The patients were well controlled with regard to HbA(1c), lipids and blood pressure. Cardiovascular autonomic neuropathy was assessed by measures of resting heart rate variability and cardiovascular autonomic reflex tests. Diabetic peripheral neuropathy...

  9. Exonuclease-assisted multicolor aptasensor for visual detection of ochratoxin A based on G-quadruplex-hemin DNAzyme-mediated etching of gold nanorod.

    Science.gov (United States)

    Yu, Xinhui; Lin, Yaohui; Wang, Xusheng; Xu, Liangjun; Wang, Zongwen; Fu, FengFu

    2018-04-21

    An exonuclease-assisted multicolor aptasensor was developed for the visual detection of ochratoxin A (OTA). It is based on the etching of gold nanorods (AuNRs) mediated by a G-quadruplex-hemin DNAzyme. A DNA sequence (AG4-OTA) was designed that comprises a hemin aptamer and an OTA aptamer. OTA binds to AG4-OTA to form an antiparallel G-quadruplex, which halts its digestion by exonuclease I (Exo I) from the 3'-end of AG4-OTA. Thus, the retained hemin aptamer can bind to hemin to form a G-quadruplex-hemin DNAzyme. This DNAzyme has peroxidase-like activity that catalyzes the oxidation of 3,3',5,5'-tetramethylbenzidine (TMB) by H 2 O 2 to produce its diimine derivative (TMB 2+ ) in acidic solution. TMB 2+ can etch the AuNRs by oxidizing Au(0) into Au(I). This results in the generation of rainbow-like colors and provides a multicolor platform for the visual detection of OTA. The assay is based on the use of a single isolated aptamer and possesses obvious advantages such as multi-color visual inspection, relatively high sensitivity and accuracy. It can be used to detect as little as 30 nM concentrations of OTA by visual observation and even 10 nM concentrations by spectrophotometry. The method was successfully applied to the determination of OTA in spiked beer where it gave recoveries of 101-108%, with a relative standard deviation (RSD, n = 5) of <5%. Graphical abstract Schematic of an exonuclease-assisted multicolor bioassay based on the G-quadruplex-hemin DNAzyme-mediated etching of gold nanorods (AuNRs). It enables visual detection of ochratoxin A (OTA) with a detection limit of 30 nM.

  10. Developmental visual perception deficits with no indications of prosopagnosia in a child with abnormal eye movements.

    Science.gov (United States)

    Gilaie-Dotan, Sharon; Doron, Ravid

    2017-06-01

    Visual categories are associated with eccentricity biases in high-order visual cortex: Faces and reading with foveally-biased regions, while common objects and space with mid- and peripherally-biased regions. As face perception and reading are among the most challenging human visual skills, and are often regarded as the peak achievements of a distributed neural network supporting common objects perception, it is unclear why objects, which also rely on foveal vision to be processed, are associated with mid-peripheral rather than with a foveal bias. Here, we studied BN, a 9 y.o. boy who has normal basic-level vision, abnormal (limited) oculomotor pursuit and saccades, and shows developmental object and contour integration deficits but with no indication of prosopagnosia. Although we cannot infer causation from the data presented here, we suggest that normal pursuit and saccades could be critical for the development of contour integration and object perception. While faces and perhaps reading, when fixated upon, take up a small portion of central visual field and require only small eye movements to be properly processed, common objects typically prevail in mid-peripheral visual field and rely on longer-distance voluntary eye movements as saccades to be brought to fixation. While retinal information feeds into early visual cortex in an eccentricity orderly manner, we hypothesize that propagation of non-foveal information to mid and high-order visual cortex critically relies on circuitry involving eye movements. Limited or atypical eye movements, as in the case of BN, may hinder normal information flow to mid-eccentricity biased high-order visual cortex, adversely affecting its development and consequently inducing visual perceptual deficits predominantly for categories associated with these regions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. [Activation of peripheral T lymphocytes in children with epilepsy and production of cytokines].

    Science.gov (United States)

    Yang, Jie; Hu, Chongkang; Jiang, Xun

    2016-09-01

    Objective To study the state of peripheral T lymphocytes and cytokine levels in children with epilepsy. Methods Twenty children with epilepsy and 20 healthy age-matched children were recruited and their peripheral blood was collected. The activation of T lymphocytes was evaluated by detecting the expressions of CD25, CD69 and cytotoxic T lymphocyte-assicated antigen 4 (CTLA4). The function of T lymphocytes was evaluated by detecting the expressions of interferon γ (IFN-γ), tumor necrosis factor α (TNF-α), IL-17A and IL-6. The activation of regulatory T cells (Tregs) was evaluated by detecting the expression of IL-10. Results Children with epilepsy had higher expressions of CD25, CD69 and CTLA-4 in T lymphocytes than the controls did. The expressions of IFN-γ, TNF-α, IL-17A and IL-6 in T lymphocytes of children with epilepsy were higher than those of the controls. Frequency of Tregs producing IL-10 was higher in children with epilepsy as compared with the controls. Conclusion Peripheral T lymphocytes of children with epilepsy are activated and produce cytokines.

  12. Automatic Detection of Optic Disc in Retinal Image by Using Keypoint Detection, Texture Analysis, and Visual Dictionary Techniques

    Directory of Open Access Journals (Sweden)

    Kemal Akyol

    2016-01-01

    Full Text Available With the advances in the computer field, methods and techniques in automatic image processing and analysis provide the opportunity to detect automatically the change and degeneration in retinal images. Localization of the optic disc is extremely important for determining the hard exudate lesions or neovascularization, which is the later phase of diabetic retinopathy, in computer aided eye disease diagnosis systems. Whereas optic disc detection is fairly an easy process in normal retinal images, detecting this region in the retinal image which is diabetic retinopathy disease may be difficult. Sometimes information related to optic disc and hard exudate information may be the same in terms of machine learning. We presented a novel approach for efficient and accurate localization of optic disc in retinal images having noise and other lesions. This approach is comprised of five main steps which are image processing, keypoint extraction, texture analysis, visual dictionary, and classifier techniques. We tested our proposed technique on 3 public datasets and obtained quantitative results. Experimental results show that an average optic disc detection accuracy of 94.38%, 95.00%, and 90.00% is achieved, respectively, on the following public datasets: DIARETDB1, DRIVE, and ROC.

  13. Rapid visual and spectrophotometric nitrite detection by cyclometalated ruthenium complex.

    Science.gov (United States)

    Lo, Hoi-Shing; Lo, Ka-Wai; Yeung, Chi-Fung; Wong, Chun-Yuen

    2017-10-16

    Quantitative determination of nitrite ion (NO 2 - ) is of great importance in environmental and clinical investigations. A rapid visual and spectrophotometric assay for NO 2 - detection was developed based on a newly designed ruthenium complex, [Ru(npy)([9]aneS3)(CO)](ClO 4 ) (denoted as RuNPY; npy = 2-(1-naphthyl)pyridine, [9]aneS3 = 1,4,7-trithiacyclononane). This complex traps NO + produced in acidified NO 2 - solution, and yields observable color change within 1 min at room temperature. The assay features excellent dynamic range (1-840 μmol L -1 ) and high selectivity, and its limit of detection (0.39 μmol L -1 ) is also well below the guideline values for drinking water recommended by WHO and U.S. EPA. Practical use of this assay in tap water and human urine was successfully demonstrated. Overall, the rapidity and selectivity of this assay overcome the problems suffered by the commonly used modified Griess assays for nitrite determination. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Study of peripheral circulation in non-pregnant, pregnant and pre-eclamptic women using applied potential tomography.

    Science.gov (United States)

    Ahmed, Badreldeen

    2004-08-01

    Profound changes are known to occur in the cardiovascular system during pregnancy, involving an increase in cardiac output and a fall in peripheral resistance. In some women these adaptations may be inappropriate and this may result in pregnancy-induced hypertension and pre-eclampsia. The aims of the study were to evaluate the relatively new, non-invasive technique of applied potential tomography (APT) in measurements of peripheral blood flow, to study peripheral blood flow in a sample of non-pregnant, pregnant and pre-eclamptic women, and to investigate whether the adaptive changes in the peripheral circulation are different in pre-eclampsia compared with normal pregnancy. Applied potential tomography was used to assess peripheral vascular reactivity, by monitoring fluid distribution in calf muscles during postural change. The APT technique was able to detect peripheral vasoconstriction in response to an increase in intramural pressure brought about by passive lowering of the leg (peripheral mechanisms). The peripheral vasoconstriction response was found to be more prominent in woman with pre-eclampsia. The presence of a local reflex in the lower limb had been postulated and the effect of this reflex on the peripheral circulation could be detected using APT, regardless of how it was initiated. In normal pregnant women this reflex was diminished when compared to non-pregnant women, which might contribute to the reduction in peripheral vascular resistance seen in normal pregnancy. This reflex was defective in pre-eclampsia and this lack of adaptation may be a local reflex contributing to the raised peripheral resistance, which in turn may be a factor in high blood pressure in pre-eclampsia.

  15. Significance of detecting circulating hepatocellular carcinoma cells in peripheral blood of hepatocellular carcinoma patients by nested reverse transcription-polymerase chain reaction and its clinical value: a retrospective study.

    Science.gov (United States)

    Liu, Yang; Wang, Yue-ru; Wang, Long; Song, Rui-mei; Zhou, Bo; Song, Zhen-shun

    2014-01-01

    Circulating hepatocellular carcinoma cells may be detected by reverse transcription-polymerase chain reaction. We investigated the relationship between circulating hepatocellular carcinoma cells and hepatoma patient survival after different managements and survival periods. Peripheral vein blood (5 ml) samples were obtained from 113 patients with hepatocellular carcinoma and from 33 control subjects (9 with liver cirrhosis after hepatitis B, 14 with chronic hepatitis B, 10 healthy individuals) between January 1, 2009, and December 31, 2013. To detect circulating hepatocellular carcinoma cells in peripheral blood, alpha-fetoprotein messenger RNA was amplified from total RNA extracted from whole blood by reverse transcription-polymerase chain reaction. Alpha-fetoprotein messenger RNA was detected in 59 blood samples from the hepatocellular carcinoma patients (59/113, 52.2%). In contrast, there were no clinical control subjects whose samples showed detectable alpha-fetoprotein messenger RNA. The presence of alpha-fetoprotein messenger RNA in blood seemed to be correlated with the stage (by TNM classification) of hepatocellular carcinoma, serum alpha-fetoprotein value, and the presence of intrahepatic metastasis, portal vein thrombosis, tumor diameter and/or distant metastasis. In addition, alpha-fetoprotein messenger RNA was detected in the blood of 25 patients showing distant metastasis at extrahepatic organs (100%), in contrast to 32 of 88 cases without metastasis (36.4%). All the patients with hepatocellular carcinoma were followed. Seventeen patients with resection of a T 2 stage hepatocellular carcinoma had a survival of 3.2 years after surgical management, 38 cases with resection of a T3 stage hepatocellular carcinoma had a 1.3-year survival, and only 37 cases with T4 stage disease after different treatments except surgery survived for 0.6 years (P <0.01). The presence of alpha-fetoprotein messenger RNA in peripheral blood may be an indicator of circulating

  16. Visual assessment of brain magnetic resonance imaging detects injury to cognitive regulatory sites in patients with heart failure.

    Science.gov (United States)

    Pan, Alan; Kumar, Rajesh; Macey, Paul M; Fonarow, Gregg C; Harper, Ronald M; Woo, Mary A

    2013-02-01

    Heart failure (HF) patients exhibit depression and executive function impairments that contribute to HF mortality. Using specialized magnetic resonance imaging (MRI) analysis procedures, brain changes appear in areas regulating these functions (mammillary bodies, hippocampi, and frontal cortex). However, specialized MRI procedures are not part of standard clinical assessment for HF (which is usually a visual evaluation), and it is unclear whether visual MRI examination can detect changes in these structures. Using brain MRI, we visually examined the mammillary bodies and frontal cortex for global and hippocampi for global and regional tissue changes in 17 HF and 50 control subjects. Significantly global changes emerged in the right mammillary body (HF 1.18 ± 1.13 vs control 0.52 ± 0.74; P = .024), right hippocampus (HF 1.53 ± 0.94 vs control 0.80 ± 0.86; P = .005), and left frontal cortex (HF 1.76 ± 1.03 vs control 1.24 ± 0.77; P = .034). Comparison of the visual method with specialized MRI techniques corroborates right hippocampal and left frontal cortical, but not mammillary body, tissue changes. Visual examination of brain MRI can detect damage in HF in areas regulating depression and executive function, including the right hippocampus and left frontal cortex. Visual MRI assessment in HF may facilitate evaluation of injury to these structures and the assessment of the impact of potential treatments for this damage. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. The Distinct Role of the Amygdala, Superior Colliculus and Pulvinar in Processing of Central and Peripheral Snakes.

    Directory of Open Access Journals (Sweden)

    Inês Almeida

    Full Text Available Visual processing of ecologically relevant stimuli involves a central bias for stimuli demanding detailed processing (e.g., faces, whereas peripheral object processing is based on coarse identification. Fast detection of animal shapes holding a significant phylogenetic value, such as snakes, may benefit from peripheral vision. The amygdala together with the pulvinar and the superior colliculus are implicated in an ongoing debate regarding their role in automatic and deliberate spatial processing of threat signals.Here we tested twenty healthy participants in an fMRI task, and investigated the role of spatial demands (the main effect of central vs. peripheral vision in the processing of fear-relevant ecological features. We controlled for stimulus dependence using true or false snakes; snake shapes or snake faces and for task constraints (implicit or explicit. The main idea justifying this double task is that amygdala and superior colliculus are involved in both automatic and controlled processes. Moreover the explicit/implicit instruction in the task with respect to emotion is not necessarily equivalent to explicit vs. implicit in the sense of endogenous vs. exogenous attention, or controlled vs. automatic processes.We found that stimulus-driven processing led to increased amygdala responses specifically to true snake shapes presented in the centre or in the peripheral left hemifield (right hemisphere. Importantly, the superior colliculus showed significantly biased and explicit central responses to snake-related stimuli. Moreover, the pulvinar, which also contains foveal representations, also showed strong central responses, extending the results of a recent single cell pulvinar study in monkeys. Similar hemispheric specialization was found across structures: increased amygdala responses occurred to true snake shapes presented to the right hemisphere, with this pattern being closely followed by the superior colliculus and the pulvinar

  18. Stages of the recognition and roentgenological semiotics of minimal peripheric lung cancer

    International Nuclear Information System (INIS)

    Lindenbraten, L.D.

    1987-01-01

    The system of diagnosis of peripheral cancer should be aimed at its detection at stage TI m , i.e. at the detection of a tumor whose shadow on a radiogram 70x70 mm was within 0.5-1.5 cm, and on a plain chest X-ray it was within. Fluorographic and roentgenographic semiotics of minimal peripheral cancer was considered on 40 cases. it was pointed out that the diagnosis of early stages of tumor development could be made only by improving the organizational basis of mass screening by setting up consultative cancer pulmonological commissions. Physicians should be aware of minimum changes in the pulmonary tissue

  19. Visual Ecology and the Development of Visually Guided Behavior in the Cuttlefish

    OpenAIRE

    Darmaillacq, Anne-Sophie; Mezrai, Nawel; O'Brien, Caitlin E.; Dickel, Ludovic

    2017-01-01

    International audience; Cuttlefish are highly visual animals, a fact reflected in the large size of their eyes and visual-processing centers of their brain. Adults detect their prey visually, navigate using visual cues such as landmarks or the e-vector of polarized light and display intense visual patterns during mating and agonistic encounters. Although much is known about the visual system in adult cuttlefish, few studies have investigated its development and that of visually-guided behavio...

  20. Long-term Outcome of Argon Laser Peripheral Iridoplasty in the Management of Plateau Iris Syndrome Eyes.

    Science.gov (United States)

    Peterson, Jeffrey R; Anderson, John W; Blieden, Lauren S; Chuang, Alice Z; Feldman, Robert M; Bell, Nicholas P

    2017-09-01

    To report long-term (>5 y) outcomes of plateau iris syndrome patients treated with argon laser peripheral iridoplasty (ALPI). A retrospective chart review was performed on all patients with plateau iris syndrome treated with ALPI from 1996 to 2007. The study included 22 eyes from 22 patients with plateau iris after peripheral iridotomy that were followed for at least 1 year after ALPI. The primary outcome was incidence of needing any intraocular pressure (IOP)-lowering medications or surgery (either a filtering procedure or phacoemulsification). Demographic and baseline clinical data were summarized by mean (±SD) or frequency (percentage). Snellen best-corrected visual acuity was converted to logMAR. The paired t test was used to compare IOP changes, number of IOP-lowering medications, and best-corrected visual acuity from baseline to annual follow-up. Mean follow-up was 76 months. Only 2 (9%) eyes maintained an IOPiris in our patient population.

  1. Triple Peripheral Nerve Injury Accompanying to Traumatic Brain Injury: A Case Report

    Directory of Open Access Journals (Sweden)

    Ižlknur Can

    2014-02-01

    Full Text Available Secondary injuries especially extremity fractures may be seen concurrently with traumatic brain injury (TBI. Peripheral nerve damages may accompany to these fractures and may be missed out, especially in acute stage. In this case report; damage of radial, ulnar and median nerves which was developed secondarily to distal humerus fracture that could not be detected in acute stage, in a patient who had motor vehicle accident (MVA. 29-year-old male patient was admitted with weakness in the right upper extremity. 9 months ago, he had traumatic brain injury because of MVA, and fracture of distal humerus was detected in follow-ups. Upon the suspect of the peripheral nerve injury, the diagnosis was confirmed with ENMG. The patient responded well to the rehabilitation program treatment. In a TBI patient, it must be kept in mind that there might be a secondary trauma and therefore peripheral nerve lesions may accompany to TBI.

  2. Sweet bee venom pharmacopuncture for chemotherapy-induced peripheral neuropathy.

    Science.gov (United States)

    Yoon, Jeungwon; Jeon, Ju-Hyun; Lee, Yeon-Weol; Cho, Chong-Kwan; Kwon, Ki-Rok; Shin, Ji-Eun; Sagar, Stephen; Wong, Raimond; Yoo, Hwa-Seung

    2012-08-01

    Chemotherapy-induced peripheral neuropathy (CIPN) is sensory and motor nerve damage to the peripheral nervous system caused by chemotherapeutic agents. It often causes pain and other varying degrees of neuropathic symptoms accompanied by functional limitations and reduced quality of life. Currently, there is no standard treatment protocol for the treatment of CIPN. In need of more research to develop new therapeutic options focusing on their safety, efficacy, and long-term sustained clinical effects, a pilot study of sweet bee venom pharmacopuncture (SBVP) for CIPN was conducted to build up preliminary efficacy data in the process of preparing for a future larger scale randomized controlled SBVP trial for CIPN. We conducted a prospective case series by analyzing the clinical observations made of CIPN patients treated with SBVP. A total of 11 eligible consecutive CIPN patients who visited East-West Cancer Center from June 1, 2010, to February 28, 2011, were treated with total of six SBVP treatments given within the 3-week period. The outcomes were measured using World Health Organization Common Toxicity Criteria for Peripheral neuropathy (WHO grading system), Patient Neurotoxicity Questionnaire (PNQ), Visual Analogue System (VAS), and Health-Related Quality of Life (HRQOL) collected at the baseline, post-second, fourth, and the final treatment. Patients were followed 3 weeks into no intervention to determine the sustained effects of pharmacopuncture. Both of the WHO CIPN grade and PNQ scores have shown a decrease in the level of neuropathy. VAS pain level has also shown a great decrease and improvement in patients' quality of life have also been detected though modest. Changes in WHO grade, VAS and Total HRQOL scores between the baseline and after the last treatment session were significant. Changes in WHO grade, Total PNQ, PNQ-sensory, VAS, Total HRQOL, and HRQOL-functional scores between the baseline and the 3-week follow-up were significant. The positive result

  3. Simple method for culture of peripheral blood lymphocytes of Testudinidae.

    Science.gov (United States)

    Silva, T L; Silva, M I A; Venancio, L P R; Zago, C E S; Moscheta, V A G; Lima, A V B; Vizotto, L D; Santos, J R; Bonini-Domingos, C R; Azeredo-Oliveira, M T V

    2011-12-06

    We developed and optimized a simple, efficient and inexpensive method for in vitro culture of peripheral blood lymphocytes from the Brazilian tortoise Chelonoidis carbonaria (Testudinidae), testing various parameters, including culture medium, mitogen concentration, mitotic index, culture volume, incubation time, and mitotic arrest. Peripheral blood samples were obtained from the costal vein of four couples. The conditions that gave a good mitotic index were lymphocytes cultured at 37°C in minimum essential medium (7.5 mL), with phytohemagglutinin as a mitogen (0.375 mL), plus streptomycin/penicillin (0.1 mL), and an incubation period of 72 h. Mitotic arrest was induced by 2-h exposure to colchicine (0.1 mL), 70 h after establishing the culture. After mitotic arrest, the cells were hypotonized with 0.075 M KCl for 2 h and fixed with methanol/acetic acid (3:1). The non-banded mitotic chromosomes were visualized by Giemsa staining. The diploid chromosome number of C. carbonaria was found to be 52 in females and males, and sex chromosomes were not observed. We were able to culture peripheral blood lymphocytes of a Brazilian tortoise in vitro, for the preparation of mitotic chromosomes.

  4. Comparative proteomic analyses of macular and peripheral retina of cynomolgus monkeys (Macaca fascicularis).

    Science.gov (United States)

    Okamoto, Haru; Umeda, Shinsuke; Nozawa, Takehiro; Suzuki, Michihiro T; Yoshikawa, Yasuhiro; Matsuura, Etsuko T; Iwata, Takeshi

    2010-01-01

    The central region of the primate retina is called the macula. The fovea is located at the center of the macula, where the photoreceptors are concentrated to create a neural network adapted for high visual acuity. Damage to the fovea, e.g., by macular dystrophies and age-related macular degeneration, can reduce central visual acuity. The molecular mechanisms leading to these diseases are most likely dependent on the proteins in the macula which differ from those in the peripheral retina in expression level. To investigate whether the distribution of proteins in the macula is different from the peripheral retina, proteomic analyses of tissues from these two regions of cynomolgus monkeys were compared. Two-dimensional gel electrophoresis and mass spectrometry identified 26 proteins that were present only in the macular gel spots. The expression levels of five proteins, cone photoreceptor specific arrestin-C, gamma-synuclein, epidermal fatty acid binding protein, tropomyosin 1alpha chain, and heterogeneous nuclear ribonucleoproteins A2/B1, were significantly higher in the macula than in the peripheral retina. Immunostaining of macula sections by antibodies to each identified protein revealed unique localization in the retina, retinal pigment epithelial cells and the choroidal layer. Some of these proteins were located in cells with higher densities in the macula. We suggest that it will be important to study these proteins to determine their contribution to the pathogenesis and progression of macula diseases.

  5. Absent Audiovisual Integration Elicited by Peripheral Stimuli in Parkinson’s Disease

    Directory of Open Access Journals (Sweden)

    Yanna Ren

    2018-01-01

    Full Text Available The basal ganglia, which have been shown to be a significant multisensory hub, are disordered in Parkinson’s disease (PD. This study was to investigate the audiovisual integration of peripheral stimuli in PD patients with/without sleep disturbances. Thirty-six age-matched normal controls (NC and 30 PD patients were recruited for an auditory/visual discrimination experiment. The mean response times for each participant were analyzed using repeated measures ANOVA and race model. The results showed that the response to all stimuli was significantly delayed for PD compared to NC (all p0.05. The current results showed that audiovisual multisensory integration for peripheral stimuli is absent in PD regardless of sleep disturbances and further suggested the abnormal audiovisual integration might be a potential early manifestation of PD.

  6. Near-infrared vascular imaging in peripheral venous and arterial access

    OpenAIRE

    Cuper, N.J.

    2012-01-01

    Venous and arterial access are among the most widespread medical procedures performed in children. Especially in young children venous and arterial access can be problematic due to tiny blood vessels that are difficult to localize beneath a layer of baby fat. This thesis describes the development and clinical evaluation of the VascuLuminator, a guidance tool for peripheral venous and arterial access by visualizing blood vessels underneath the skin with near-infrared light. In a third to a fif...

  7. Detection of Angiostrongylus cantonensis in the Blood and Peripheral Tissues of Wild Hawaiian Rats (Rattus rattus by a Quantitative PCR (qPCR Assay.

    Directory of Open Access Journals (Sweden)

    Susan I Jarvi

    Full Text Available The nematode Angiostrongylus cantonensis is a rat lungworm, a zoonotic pathogen that causes human eosinophilic meningitis and ocular angiostrongyliasis characteristic of rat lungworm (RLW disease. Definitive diagnosis is made by finding and identifying A. cantonensis larvae in the cerebral spinal fluid or by using a custom immunological or molecular test. This study was conducted to determine if genomic DNA from A. cantonensis is detectable by qPCR in the blood or tissues of experimentally infected rats. F1 offspring from wild rats were subjected to experimental infection with RLW larvae isolated from slugs, then blood or tissue samples were collected over multiple time points. Blood samples were collected from 21 rats throughout the course of two trials (15 rats in Trial I, and 6 rats in Trial II. In addition to a control group, each trial had two treatment groups: the rats in the low dose (LD group were infected by approximately 10 larvae and the rats in the high dose (HD group were infected with approximately 50 larvae. In Trial I, parasite DNA was detected in cardiac bleed samples from five of five LD rats and five of five HD rats at six weeks post-infection (PI, and three of five LD rats and five of five HD rats from tail tissue. In Trial II, parasite DNA was detected in peripheral blood samples from one of two HD rats at 53 minutes PI, one of two LD rats at 1.5 hours PI, one of two HD rats at 18 hours PI, one of two LD rats at five weeks PI and two of two at six weeks PI, and two of two HD rats at weeks five and six PI. These data demonstrate that parasite DNA can be detected in peripheral blood at various time points throughout RLW infection in rats.

  8. Detection of Angiostrongylus cantonensis in the Blood and Peripheral Tissues of Wild Hawaiian Rats (Rattus rattus) by a Quantitative PCR (qPCR) Assay.

    Science.gov (United States)

    Jarvi, Susan I; Pitt, William C; Farias, Margaret E; Shiels, Laura; Severino, Michael G; Howe, Kathleen M; Jacquier, Steven H; Shiels, Aaron B; Amano, Karis K; Luiz, Blaine C; Maher, Daisy E; Allison, Maureen L; Holtquist, Zachariah C; Scheibelhut, Neil T

    2015-01-01

    The nematode Angiostrongylus cantonensis is a rat lungworm, a zoonotic pathogen that causes human eosinophilic meningitis and ocular angiostrongyliasis characteristic of rat lungworm (RLW) disease. Definitive diagnosis is made by finding and identifying A. cantonensis larvae in the cerebral spinal fluid or by using a custom immunological or molecular test. This study was conducted to determine if genomic DNA from A. cantonensis is detectable by qPCR in the blood or tissues of experimentally infected rats. F1 offspring from wild rats were subjected to experimental infection with RLW larvae isolated from slugs, then blood or tissue samples were collected over multiple time points. Blood samples were collected from 21 rats throughout the course of two trials (15 rats in Trial I, and 6 rats in Trial II). In addition to a control group, each trial had two treatment groups: the rats in the low dose (LD) group were infected by approximately 10 larvae and the rats in the high dose (HD) group were infected with approximately 50 larvae. In Trial I, parasite DNA was detected in cardiac bleed samples from five of five LD rats and five of five HD rats at six weeks post-infection (PI), and three of five LD rats and five of five HD rats from tail tissue. In Trial II, parasite DNA was detected in peripheral blood samples from one of two HD rats at 53 minutes PI, one of two LD rats at 1.5 hours PI, one of two HD rats at 18 hours PI, one of two LD rats at five weeks PI and two of two at six weeks PI, and two of two HD rats at weeks five and six PI. These data demonstrate that parasite DNA can be detected in peripheral blood at various time points throughout RLW infection in rats.

  9. Vasculitic peripheral neuropathy

    Directory of Open Access Journals (Sweden)

    Mona Amini

    2014-02-01

    Full Text Available Primary systemic vasculitis in pre-capillary arteries is associated with peripheral neuropathy. In some types of systematic vasculitis about 60 % of patients have peripheral nervous system (PNS involvement. In vasculitic peripheral neuropathies (VPN a necrotizing and inflammatory process leads to narrowing of vasa nervorum lumen and eventually the appearance of ischemic lesions in peripheral nerves. Some features might be suggestive of VPN, like: axonal nerve degeneration, wallerian-like degeneration, and diameter irregularity of nerve. Peripheral nervous system (PNS destruction during systemic vasculitides should be considered, due to its frequency and early occurrence in vasculitis progression. The first line treatment of non systematic VPNs is corticosteroid agents, but these drugs might worsen the VPNs or systemic vasculitis.

  10. Using optic flow in the far peripheral field.

    Science.gov (United States)

    McManus, Meaghan; D'Amour, Sarah; Harris, Laurence R

    2017-07-01

    Self-motion information can be used to update spatial memory of location through an estimate of a change in position. Viewing optic flow alone can create Illusory self-motion or "vection." Early studies suggested that peripheral vision is more effective than central vision in evoking vection, but controlling for retinal area and perceived distance suggests that all retinal areas may be equally effective. However, the contributions of the far periphery, beyond 90°, have been largely neglected. Using a large-field Edgeless Graphics Geometry display (EGG, Christie, Canada, field of view ±112°) and systematically blocking central (±20° to ±90°) or peripheral (viewing through tunnels ±20° to ±40°) parts of the field, we compared the effectiveness of different retinal regions at evoking forwards linear vection. Fifteen participants indicated when they had reached the position of a previously presented target after visually simulating motion down a simulated corridor. The amount of simulated travel needed to match a given target distance was modelled with a leaky spatial integrator model to estimate gains (perceived/actual distance) and a spatial decay factor. When optic flow was presented only in the far periphery (beyond 90°) gains were significantly higher than for the same motion presented full field or in only the central field, resulting in accurate performance in the range of speeds associated with normal walking. The increased effectiveness of optic flow in the peripheral field alone compared to full-field motion is discussed in terms of emerging neurophysiological studies that suggest brain areas dedicated to processing information from the far peripheral field.

  11. Visual method for detecting critical damage in railway contact strips

    Science.gov (United States)

    Judek, S.; Skibicki, J.

    2018-05-01

    Ensuring an uninterrupted supply of power in the electric traction is vital for the safety of this important transport system. For this purpose, monitoring and diagnostics of the technical condition of the vehicle’s power supply elements are becoming increasingly common. This paper presents a new visual method for detecting contact strip damage, based on measurement and analysis of the movement of the overhead contact line (OCL) wire. A measurement system configuration with a 2D camera was proposed. The experimental method has shown that contact strips damage can be detected by transverse displacement signal analysis. It has been proven that the velocity signal numerically established on that basis has a comparable level in the case of identical damage, regardless of its location on the surface of the contact strip. The proposed method belongs to the group of contact-less measurements, so it does not require interference with the structure of the catenary network nor the mounting of sensors in its vicinity. Measurement of displacements of the contact wire in 2D space makes it possible to combine the functions of existing diagnostic stands assessing the correctness of the mean contact force control adjustment of the current collector with the elements of the contact strip diagnostics, which involves detecting their damage which may result in overhead contact line rupture.

  12. PHENYTOIN-ASSOCIATED LYMPHOADENOPATHY MIMICKING A PERIPHERAL T-CELL LYMPHOMA

    Directory of Open Access Journals (Sweden)

    Mark E. Johns

    2010-09-01

    Full Text Available We report a case of phenytoin-induced pseudolymphoma in a 28-year-old male with a history of autism and seizure disorder.  The patient presented with bilateral cervical lymphadenopathy that was shown to be moderately to markedly FDG-avid on a whole body PET/CT scan.  Flow cytometry analysis of peripheral blood and bone marrow mononuclear cells detected identical T cell population with aberrant immunophenotype.  Additionally, a TCR beta gene was found to be clonally rearranged in both peripheral blood and bone marrow supporting a clonal origin of atypical T cells. However, no such clonal population of T-cells could be detected in a pathologic specimen obtained from an excisional biopsy of one of the patient’s cervical lymph nodes. After discontinuing the patient’s phenytoin, his lymphadenopathy has nearly completely resolved and circulation clonal T cell population disappeared with 12 months of follow-up.

  13. The Right Hemisphere Planum Temporale Supports Enhanced Visual Motion Detection Ability in Deaf People: Evidence from Cortical Thickness.

    Science.gov (United States)

    Shiell, Martha M; Champoux, François; Zatorre, Robert J

    2016-01-01

    After sensory loss, the deprived cortex can reorganize to process information from the remaining modalities, a phenomenon known as cross-modal reorganization. In blind people this cross-modal processing supports compensatory behavioural enhancements in the nondeprived modalities. Deaf people also show some compensatory visual enhancements, but a direct relationship between these abilities and cross-modally reorganized auditory cortex has only been established in an animal model, the congenitally deaf cat, and not in humans. Using T1-weighted magnetic resonance imaging, we measured cortical thickness in the planum temporale, Heschl's gyrus and sulcus, the middle temporal area MT+, and the calcarine sulcus, in early-deaf persons. We tested for a correlation between this measure and visual motion detection thresholds, a visual function where deaf people show enhancements as compared to hearing. We found that the cortical thickness of a region in the right hemisphere planum temporale, typically an auditory region, was greater in deaf individuals with better visual motion detection thresholds. This same region has previously been implicated in functional imaging studies as important for functional reorganization. The structure-behaviour correlation observed here demonstrates this area's involvement in compensatory vision and indicates an anatomical correlate, increased cortical thickness, of cross-modal plasticity.

  14. Enhancing links between visual short term memory, visual attention and cognitive control processes through practice: An electrophysiological insight.

    Science.gov (United States)

    Fuggetta, Giorgio; Duke, Philip A

    2017-05-01

    The operation of attention on visible objects involves a sequence of cognitive processes. The current study firstly aimed to elucidate the effects of practice on neural mechanisms underlying attentional processes as measured with both behavioural and electrophysiological measures. Secondly, it aimed to identify any pattern in the relationship between Event-Related Potential (ERP) components which play a role in the operation of attention in vision. Twenty-seven participants took part in two recording sessions one week apart, performing an experimental paradigm which combined a match-to-sample task with a memory-guided efficient visual-search task within one trial sequence. Overall, practice decreased behavioural response times, increased accuracy, and modulated several ERP components that represent cognitive and neural processing stages. This neuromodulation through practice was also associated with an enhanced link between behavioural measures and ERP components and with an enhanced cortico-cortical interaction of functionally interconnected ERP components. Principal component analysis (PCA) of the ERP amplitude data revealed three components, having different rostro-caudal topographic representations. The first component included both the centro-parietal and parieto-occipital mismatch triggered negativity - involved in integration of visual representations of the target with current task-relevant representations stored in visual working memory - loaded with second negative posterior-bilateral (N2pb) component, involved in categorising specific pop-out target features. The second component comprised the amplitude of bilateral anterior P2 - related to detection of a specific pop-out feature - loaded with bilateral anterior N2, related to detection of conflicting features, and fronto-central mismatch triggered negativity. The third component included the parieto-occipital N1 - related to early neural responses to the stimulus array - which loaded with the second

  15. The clinical identification of peripheral neuropathy among older persons.

    Science.gov (United States)

    Richardson, James K

    2002-11-01

    To identify simple clinical rules for the detection of a diffuse peripheral neuropathy among older outpatients. Observational, blinded, controlled study. A tertiary-care electrodiagnostic laboratory and biomechanics laboratory. One hundred research subjects, 68 with electrodiagnostic evidence of peripheral neuropathy, between the ages of 50 and 80 years. Not applicable. One examiner, unaware of the results of electrodiagnostic testing, evaluated Achilles' and patellar reflexes, Romberg testing, semiquantified vibration, and position sense at the toe and ankle in all subjects, and unipedal stance time and the Michigan Diabetes Neuropathy Score in a subset of subjects. Significant group differences were present in all clinical measures tested. Three signs, Achilles' reflex (absent despite facilitation), vibration (128Hz tuning fork perceived for <10s), and position sense (<8/10 1-cm trials) at the toe, were the best predictors of peripheral neuropathy on both univariate and logistic regression (pseudo R(2)=.744) analyses. The presence of 2 or 3 signs versus 0 or 1 sign identified peripheral neuropathy with sensitivity, specificity, and positive and negative predictive values of 94.1%, 84.4%, 92.8%, and 87.1%, respectively. Values were similar among subgroups of subjects with and without diabetes mellitus. When other clinicians applied the technique to 12 more subjects, excellent interrater reliability regarding the presence of peripheral neuropathy (kappa=.833) and good to excellent interrater reliability for each sign (kappa range,.667-1.00) were shown. Among older persons, the presence of 2 or 3 of the 3 clinical signs strongly suggested electrodiagnostic evidence of a peripheral neuropathy, regardless of etiology. Age-related decline in peripheral nerve function need not be a barrier to the clinical recognition of a diffuse peripheral neuropathy among older persons. Copyright 2002 by the American Congress of Rehabilitation Medicine and the American Academy of

  16. Teach yourself visually OS X Mavericks

    CERN Document Server

    McFedries, Paul

    2013-01-01

    Clear, step-by-step instruction guides you through OS X Mavericks If you want to get quickly up to speed on the newest (and now cat-free) OS X operating system, OS X Mavericks, this easy-to-follow book is just the ticket. Designed for visual learners, Teach Yourself VISUALLY OS X Mavericks uses rich, full-color screenshots and illustrations to show rather than tell you how to use Mavericks. You'll learn how to customize your Mac, enjoy digital media, connect common peripherals, and get the most out of the very latest enhancements, including iBooks, Maps, iCloud, and Calendar. Shows you how t

  17. Detection and Visualization of Android Malware Behavior

    Directory of Open Access Journals (Sweden)

    Oscar Somarriba

    2016-01-01

    Full Text Available Malware analysts still need to manually inspect malware samples that are considered suspicious by heuristic rules. They dissect software pieces and look for malware evidence in the code. The increasing number of malicious applications targeting Android devices raises the demand for analyzing them to find where the malcode is triggered when user interacts with them. In this paper a framework to monitor and visualize Android applications’ anomalous function calls is described. Our approach includes platform-independent application instrumentation, introducing hooks in order to trace restricted API functions used at runtime of the application. These function calls are collected at a central server where the application behavior filtering and a visualization take place. This can help Android malware analysts in visually inspecting what the application under study does, easily identifying such malicious functions.

  18. Persistence, Spatial Distribution and Implications for Progression Detection of Blind Parts of the Visual Field in Glaucoma : A Clinical Cohort Study

    NARCIS (Netherlands)

    Montolio, Francisco G. Junoy; Wesselink, Christiaan; Jansonius, Nomdo M.

    2012-01-01

    Background: Visual field testing is an essential part of glaucoma care. It is hampered by variability related to the disease itself, response errors and fatigue. In glaucoma, blind parts of the visual field contribute to the diagnosis but - once established - not to progression detection; they only

  19. Development of a method for detecting nuclear fuel debris and water leaks at a nuclear reactor/containment vessel by flow visualization

    International Nuclear Information System (INIS)

    Umezawa, Shuichi; Tanaka, Katsuhiko

    2013-01-01

    It is the important issue to fill up each nuclear reactor/containment vessel with water and to take out debris of damaged fuel from them for decommissioning of Fukushima Daiichi nuclear power plants. It is necessary to detect the debris and water leaks at a nuclear reactor/containment vessel for the purpose. However, the method is not completely developed in the present stage. Accordingly, we have developed a method for detecting debris and water leaks at a nuclear reactor/containment vessel by flow visualization. Experiments of the flow visualization were conducted using two types of water tanks. An optical fiber and a collimator lens were employed for modifying a straight laser beam into a sheet projection. Some visualized images were obtained through the experiments. Particle Image Velocimetry, i.e. PIV, analysis was applied to the images for quantitative flow rate analysis. Consequently, it is considered that the flow visualization method has a possibility for the practical use. (author)

  20. Clinical study of the visual field defects caused by occipital lobe lesions.

    Science.gov (United States)

    Ogawa, Katsuhiko; Ishikawa, Hiroshi; Suzuki, Yutaka; Oishi, Minoru; Kamei, Satoshi

    2014-01-01

    The central visual field is projected to the region from the occipital tip to the posterior portion of the medial area in the striate cortex. However, central visual field disturbances have not been compared with the location of the lesions in the striate cortex. Thirteen patients with visual field defects caused by partial involvement of the striate cortex were enrolled. The lesions were classified according to their location into the anterior portion, the posterior portion of the medial area, and the occipital tip. Visual field defects were examined by the Goldmann perimetry, the Humphrey perimetry and the auto-plot tangent screen. We defined a defect within the central 10° of vision as a central visual field disturbance. The visual field defects in 13 patients were compared with the location of their lesions in the striate cortex. The medial area was involved in 7 patients with no involvement of the occipital tip. In 2 of them, peripheral homonymous hemianopia without central visual field disturbance was shown, and their lesions were located only in the anterior portion. One patient with a lesion in the posterior portion alone showed incomplete central homonymous hemianopia. Three of 4 patients with lesions located in both the anterior and posterior portions of the medial area showed incomplete central homonymous hemianopia and peripheral homonymous hemianopia. The occipital tip was involved in 6 patients. Five of them had small lesions in the occipital tip alone and showed complete central homonymous hemianopia or quadrantanopia. The other patient with a lesion in the lateral posterior portion and bilateral occipital tip lesions showed bilateral slight peripheral visual field disturbance in addition to complete central homonymous hemianopia on both sides. Lesions in the posterior portion of the medial area as well as the occipital tip caused central visual field disturbance in our study, as indicated in previous reports. Central homonymous hemianopia tended to

  1. Study on visual detection method for wind turbine blade failure

    Science.gov (United States)

    Chen, Jianping; Shen, Zhenteng

    2018-02-01

    Start your abstract here…At present, the non-destructive testing methods of the wind turbine blades has fiber bragg grating, sound emission and vibration detection, but there are all kinds of defects, and the engineering application is difficult. In this regard, three-point slope deviation method, which is a kind of visual inspection method, is proposed for monitoring the running status of wind turbine blade based on the image processing technology. A better blade image can be got through calibration, image splicing, pretreatment and threshold segmentation algorithm. Design of the early warning system to monitor wind turbine blade running condition, recognition rate, stability and impact factors of the method were statistically analysed. The experimental results shown showed that it has highly accurate and good monitoring effect.

  2. Peripheral biomarkers revisited: integrative profiling of peripheral samples for psychiatric research.

    Science.gov (United States)

    Hayashi-Takagi, Akiko; Vawter, Marquis P; Iwamoto, Kazuya

    2014-06-15

    Peripheral samples, such as blood and skin, have been used for decades in psychiatric research as surrogates for central nervous system samples. Although the validity of the data obtained from peripheral samples has been questioned and other state-of-the-art techniques, such as human brain imaging, genomics, and induced pluripotent stem cells, seem to reduce the value of peripheral cells, accumulating evidence has suggested that revisiting peripheral samples is worthwhile. Here, we re-evaluate the utility of peripheral samples and argue that establishing an understanding of the common signaling and biological processes in the brain and peripheral samples is required for the validity of such models. First, we present an overview of the available types of peripheral cells and describe their advantages and disadvantages. We then briefly summarize the main achievements of omics studies, including epigenome, transcriptome, proteome, and metabolome analyses, as well as the main findings of functional cellular assays, the results of which imply that alterations in neurotransmission, metabolism, the cell cycle, and the immune system may be partially responsible for the pathophysiology of major psychiatric disorders such as schizophrenia. Finally, we discuss the future utility of peripheral samples for the development of biomarkers and tailor-made therapies, such as multimodal assays that are used as a battery of disease and trait pathways and that might be potent and complimentary tools for use in psychiatric research. © 2013 Society of Biological Psychiatry Published by Society of Biological Psychiatry All rights reserved.

  3. An Assessment of Remote Visual Methods to Detect Cracking in Reactor Components

    International Nuclear Information System (INIS)

    Cumblidge, Stephen E.; Anderson, Michael T.; Doctor, Steven R.; Simonen, Fredric A.; Elliot, Anthony J.

    2008-01-01

    Recently, the U.S. nuclear industry has proposed replacing current volumetric and/or surface examinations of certain components in commercial nuclear power plants, as required by the American Society of Mechanical Engineers Boiler and Pressure Vessel Code Section XI, Inservice Inspection of Nuclear Power Plant Components, with a simpler visual testing (VT) method. The advantages of VT are that these tests generally involve much less radiation exposure and time to perform the examination than do volumetric examinations such as ultrasonic testing. The issues relative to the reliability of VT in determining the structural integrity of reactor components were examined. Some piping and pressure vessel components in a nuclear power station are examined using VT as they are either in high radiation fields or component geometry precludes the use of ultrasonic testing (UT) methodology. Remote VT with radiation-hardened video systems has been used by nuclear utilities to find cracks in pressure vessel cladding in pressurized water reactors, core shrouds in boiling water reactors, and to investigate leaks in piping and reactor components. These visual tests are performed using a wide variety of procedures and equipment. The techniques for remote VT use submersible closed-circuit video cameras to examine reactor components and welds. PNNL conducted a parametric study that examined the important variables influencing the effectiveness of a remote visual test. Tested variables included lighting techniques, camera resolution, camera movement, and magnification. PNNL also conducted a limited laboratory test using a commercial visual testing camera system to experimentally determine the ability of the camera system to detect cracks of various widths under ideal conditions. The results of these studies and their implications are presented in this paper

  4. Macular degeneration affects eye movement behaviour during visual search

    Directory of Open Access Journals (Sweden)

    Stefan eVan Der Stigchel

    2013-09-01

    Full Text Available Patients with a scotoma in their central vision (e.g. due to macular degeneration, MD commonly adopt a strategy to direct the eyes such that the image falls onto a peripheral location on the retina. This location is referred to as the preferred retinal locus (PRL. Although previous research has investigated the characteristics of this PRL, it is unclear whether eye movement metrics are modulated by peripheral viewing with a PRL as measured during a visual search paradigm. To this end, we tested four MD patients in a visual search paradigm and contrasted their performance with a healthy control group and a healthy control group performing the same experiment with a simulated scotoma. The experiment contained two conditions. In the first condition the target was an unfilled circle hidden among c-shaped distractors (serial condition and in the second condition the target was a filled circle (pop-out condition. Saccadic search latencies for the MD group were significantly longer in both conditions compared to both control groups. Results of a subsequent experiment indicated that this difference between the MD and the control groups could not be explained by a difference in target selection sensitivity. Furthermore, search behaviour of MD patients was associated with saccades with smaller amplitudes towards the scotoma, an increased intersaccadic interval and an increased number of eye movements necessary to locate the target. Some of these characteristics, such as the increased intersaccadic interval, were also observed in the simulation group, which indicate that these characteristics are related to the peripheral viewing itself. We suggest that the combination of the central scotoma and peripheral viewing can explain the altered search behaviour and no behavioural evidence was found for a possible reorganization of the visual system associated with the use of a PRL. Thus the switch from a fovea-based to a PRL-based reference frame impairs search

  5. Peripheral Retinal Changes Associated with Age-Related Macular Degeneration in the Age-Related Eye Disease Study 2: Age-Related Eye Disease Study 2 Report Number 12 by the Age-Related Eye Disease Study 2 Optos PEripheral RetinA (OPERA) Study Research Group.

    Science.gov (United States)

    Domalpally, Amitha; Clemons, Traci E; Danis, Ronald P; Sadda, SriniVas R; Cukras, Catherine A; Toth, Cynthia A; Friberg, Thomas R; Chew, Emily Y

    2017-04-01

    To compare rates of peripheral retinal changes in Age-Related Eye Disease Study 2 (AREDS2) participants with at least intermediate age-related macular degeneration (AMD) with control subjects without intermediate age-related changes (large drusen). Cross-sectional evaluation of clinic-based patients enrolled in AREDS2 and a prospective study. Participants from prospective studies. The 200° pseudocolor and fundus autofluorescence (FAF) images were captured on the Optos 200 Tx Ultrawide-field device (Optos, Dunfermline, Scotland) by centering on the fovea and then steering superiorly and inferiorly. The montaged images were graded at a reading center with the images divided into 3 zones (zone 1 [posterior pole], zone 2 [midperiphery], and zone 3 [far periphery]) to document the presence of peripheral lesions. Peripheral retinal lesions: drusen, hypopigmentary/hyperpigmentary changes, reticular pseudodrusen, senile reticular pigmentary changes, cobblestone degeneration, and FAF abnormalities. A total of 484 (951 eyes) AREDS2 participants with AMD (cases) and 89 (163 eyes) controls without AMD had gradable color and FAF images. In zones 2 and 3, neovascularization and geographic atrophy (GA) were present, ranging from 0.4% to 6% in eyes of cases, respectively, and GA was present in 1% of eyes of controls. Drusen were detected in 97%, 78%, and 64% of eyes of cases and 48%, 21%, and 9% of eyes of controls in zones 2 and 3 superior and 3 inferior, respectively (P < 0.001 for all). Peripheral reticular pseudodrusen were seen in 15%. Senile reticular pigmentary change was the predominant peripheral change seen in 48% of cases and 16% of controls in zone 2 (P < 0.001). Nonreticular pigment changes were less frequent in the periphery than in the posterior pole (46% vs. 76%) and negligible in controls. Peripheral retinal changes are more prevalent in eyes with AMD than in control eyes. Drusen are seen in a majority of eyes with AMD in both the mid and far periphery, whereas

  6. Incremento de la detección de lesiones cervicales mediante inspección visual. Puerto Esperanza. 2008 Detection Increase of cervix lesions by means of visual examination in Puerto Esperanza, 2008

    Directory of Open Access Journals (Sweden)

    José G Sanabria Negrín

    2011-09-01

    Full Text Available Las pruebas visuales del cuello uterino mediante ácido acético al 4-5 % (IVA y Lugol (IVSL contribuyen a detectar lesiones. Este constituye el primer reporte de su uso en Cuba. Objetivo: demostrar el incremento de la detección de lesiones cervicales premalignas y malignas mediante el uso de pruebas visuales en la APS. Método: estudio de casos-controles en Puerto Esperanza, Viñales, 2008. Universo: Mujeres de 15-64 años con relaciones sexuales penetrantes. Muestra: Mujeres con pruebas visuales y citología alterada (n1= 18 casos o no (n2= 178 controles. En Patología de Cuello se les practicó colposcopia y biopsia dirigida o por conización con asa diatérmica. Se calcularon frecuencias absolutas y relativas porcentuales y la probabilidad de detectar lesiones por las pruebas aisladas o en conjunto, además de las pruebas de rendimiento diagnóstico. Resultados: IVA e IVSL resultaron positivas en 92.9% y 79.6%, respectivamente. La probabilidad conjunta de tener lesiones fue 0.7395. Con citología alterada el 88.9 % tenía IVA+ y 77,9 % tuvo IVSL+. La colposcopia resultó positiva en el 70.9 % y la probabilidad de tener una lesión mediante pruebas visuales y la colposcopia fue 0.516. De las 136 mujeres biopsiadas resultaron útiles el 99.3%, de las cuales casi el 50 % tuvo lesiones premalignas/malignas. Las pruebas de rendimiento fueron superiores para la IVA y la IVSL que para la citología. No se detectó cáncer invasor, pero sí carcinomas in situ. Conclusión: las pruebas visuales aumentaron la cantidad de diagnósticos en 4 veces y debe generalizarse su uso.Visual examination of cervix using acetic acid up to 4-5% (VIA and Lugol's solution (VILI contribute to detect lesions. This constitutes the first report of their use in Cuba. Objective: to demonstrate the detection increase of pre-malignant and malignant cervical lesions by means of visual examination in Primary Health Care. Method: control-case studies in Puerto Esperanza, Vi

  7. Visual Saliency Models for Text Detection in Real World.

    Directory of Open Access Journals (Sweden)

    Renwu Gao

    Full Text Available This paper evaluates the degree of saliency of texts in natural scenes using visual saliency models. A large scale scene image database with pixel level ground truth is created for this purpose. Using this scene image database and five state-of-the-art models, visual saliency maps that represent the degree of saliency of the objects are calculated. The receiver operating characteristic curve is employed in order to evaluate the saliency of scene texts, which is calculated by visual saliency models. A visualization of the distribution of scene texts and non-texts in the space constructed by three kinds of saliency maps, which are calculated using Itti's visual saliency model with intensity, color and orientation features, is given. This visualization of distribution indicates that text characters are more salient than their non-text neighbors, and can be captured from the background. Therefore, scene texts can be extracted from the scene images. With this in mind, a new visual saliency architecture, named hierarchical visual saliency model, is proposed. Hierarchical visual saliency model is based on Itti's model and consists of two stages. In the first stage, Itti's model is used to calculate the saliency map, and Otsu's global thresholding algorithm is applied to extract the salient region that we are interested in. In the second stage, Itti's model is applied to the salient region to calculate the final saliency map. An experimental evaluation demonstrates that the proposed model outperforms Itti's model in terms of captured scene texts.

  8. Experimental study on visual detection for fatigue of fixed-position staff.

    Science.gov (United States)

    Nie, Baisheng; Huang, Xin; Chen, Yang; Li, Anjin; Zhang, Ruming; Huang, Jinxin

    2017-11-01

    Fatigue can lead to decreased work performance and poorer safety and health condition. Fatigue is ubiquitous in production and in life, while the research on it is mainly concentrated in the automotive driving, aircraft piloting and other fields, and it is insufficient to study on the fatigue of fixed-position staff. This paper puts forward a non-contact visual image method, which can monitor the extent of fatigue of fixed-position staff. Fatigue threshold used in judgment is obtained by processing the recorded data of visual images of the experimental subjects when fatiguing and by analyzing eye closure time, percentage of eyelid closure (PERCLOS) value, frequency and number of blinks. The results show that there is significant difference among the four indicators before and after experiment subjects undergo fatigue. The fatigue of experimental subjects is obvious when eye closure time is 3.5 s/min, PERCLOS value 6%, and blink frequency 0.4 times/s. This provides a reference for a wider range of detection of fatigue and a method for avoiding mistakes and accidents. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Microdialysis assessment of peripheral metabolism in critical limb ischemia after endovascular revascularization

    OpenAIRE

    Tozzi, Matteo; Muscianisi, Elisa; Piffaretti, Gabriele; Castelli, Patrizio

    2009-01-01

    Abstract Background Critical limb ischemia is a chronic pathologic condition defined by the lack of blood flow in peripheral circulation. Microdialysis is a well-known and sensitive method for the early detection of tissue ischemia. The aim of the present study was to use microdialysis in order to analyse cellular metabolism changes after peripheral endovascular revascularization. Methods Ten patients diagnosed with critical limb ischemia was enrolled. CMA 60 (CMA® - Solna, Sweden) catheter w...

  10. The role of peripheral vision in saccade planning: learning from people with tunnel vision.

    Science.gov (United States)

    Luo, Gang; Vargas-Martin, Fernando; Peli, Eli

    2008-12-22

    Both visually salient and top-down information are important in eye movement control, but their relative roles in the planning of daily saccades are unclear. We investigated the effect of peripheral vision loss on saccadic behaviors in patients with tunnel vision (visual field diameters 7 degrees-16 degrees) in visual search and real-world walking experiments. The patients made up to two saccades per second to their pre-saccadic blind areas, about half of which had no overlap between the post- and pre-saccadic views. In the visual search experiment, visual field size and the background (blank or picture) did not affect the saccade sizes and direction of patients (n = 9). In the walking experiment, the patients (n = 5) and normal controls (n = 3) had similar distributions of saccade sizes and directions. These findings might provide a clue about the large extent of the top-down mechanism influence on eye movement control.

  11. Visual Working Memory Enhances the Neural Response to Matching Visual Input.

    Science.gov (United States)

    Gayet, Surya; Guggenmos, Matthias; Christophel, Thomas B; Haynes, John-Dylan; Paffen, Chris L E; Van der Stigchel, Stefan; Sterzer, Philipp

    2017-07-12

    Visual working memory (VWM) is used to maintain visual information available for subsequent goal-directed behavior. The content of VWM has been shown to affect the behavioral response to concurrent visual input, suggesting that visual representations originating from VWM and from sensory input draw upon a shared neural substrate (i.e., a sensory recruitment stance on VWM storage). Here, we hypothesized that visual information maintained in VWM would enhance the neural response to concurrent visual input that matches the content of VWM. To test this hypothesis, we measured fMRI BOLD responses to task-irrelevant stimuli acquired from 15 human participants (three males) performing a concurrent delayed match-to-sample task. In this task, observers were sequentially presented with two shape stimuli and a retro-cue indicating which of the two shapes should be memorized for subsequent recognition. During the retention interval, a task-irrelevant shape (the probe) was briefly presented in the peripheral visual field, which could either match or mismatch the shape category of the memorized stimulus. We show that this probe stimulus elicited a stronger BOLD response, and allowed for increased shape-classification performance, when it matched rather than mismatched the concurrently memorized content, despite identical visual stimulation. Our results demonstrate that VWM enhances the neural response to concurrent visual input in a content-specific way. This finding is consistent with the view that neural populations involved in sensory processing are recruited for VWM storage, and it provides a common explanation for a plethora of behavioral studies in which VWM-matching visual input elicits a stronger behavioral and perceptual response. SIGNIFICANCE STATEMENT Humans heavily rely on visual information to interact with their environment and frequently must memorize such information for later use. Visual working memory allows for maintaining such visual information in the mind

  12. Detection of cyprinid herpesvirus 2 in peripheral blood cells of silver crucian carp, Carassius auratus gibelio (Bloch), suggests its potential in viral diagnosis.

    Science.gov (United States)

    Wang, H; Xu, Lj; Lu, Lq

    2016-02-01

    Epidemics caused by cyprinid herpesvirus 2 (CyHV-2) in domestic cyprinid species have been reported in both European and Asian countries. Although the mechanisms remain unknown, acute CyHV-2 infections generally result in high mortality, and the surviving carps become chronic carriers displaying no external clinical signs. In this study, in situ hybridization analysis showed that CyHV-2 tended to infect peripheral blood cells during either acute or chronic infections in silver crucian carp, Carassius auratus gibelio (Bloch). Laboratory challenge experiments coupled with real-time PCR quantification assays further indicated that steady-state levels of the viral genomic copy number in fish serum exhibited a typical 'one-step' growth curve post-viral challenge. Transcriptional expression of open reading frames (ORF) 121, which was selected due to its highest transcriptional levels in almost all tested tissues, was monitored to represent the replication kinetics of CyHV-2 in peripheral blood cells. Similar kinetic curve of active viral gene transcription in blood cells was obtained as that of serum viral load, indicating that CyHV-2 replicated in peripheral blood cells as well as in other well-characterized tissues. This study should pave the way for designing non-invasive and cost-effective serum diagnostic methods for quick detection of CyHV-2 infection. © 2015 John Wiley & Sons Ltd.

  13. Detection of tetanus toxoid-specific memory T cells in equine lymph nodes but not in peripheral blood.

    Science.gov (United States)

    Frayne, J; Stokes, C R

    1995-07-01

    The use of tetanus toxoid as a recall antigen to investigate equine immune responses would be, in theory, a useful and cost-effective model in vitro. However, by using various regimens for culturing peripheral blood mononuclear cells from horses previously immunised with toxoid no proliferative response to the antigen was obtained in vitro, whereas lymph node mononuclear cells from the same animals proliferated significantly in response to it. The lack of response by the peripheral blood mononuclear cells was not due to the presence of a suppressive factor but to a lack of recognition of the antigen by the T cells of the peripheral blood.

  14. Peripheral vision and perceptual asymmetries in young and older martial arts athletes and nonathletes.

    Science.gov (United States)

    Muiños, Mónica; Ballesteros, Soledad

    2014-11-01

    The present study investigated peripheral vision (PV) and perceptual asymmetries in young and older martial arts athletes (judo and karate athletes) and compared their performance with that of young and older nonathletes. Stimuli were dots presented at three different eccentricities along the horizontal, oblique, and vertical diameters and three interstimulus intervals. Experiment 1 showed that although the two athlete groups were faster in almost all conditions, karate athletes performed significantly better than nonathlete participants when stimuli were presented in the peripheral visual field. Experiment 2 showed that older participants who had practiced a martial art at a competitive level when they were young were significantly faster than sedentary older adults of the same age. The practiced sport (judo or karate) did not affect performance differentially, suggesting that it is the practice of martial arts that is the crucial factor, rather than the type of martial art. Importantly, older athletes lose their PV advantage, as compared with young athletes. Finally, we found that physical activity (young and older athletes) and age (young and older adults) did not alter the visual asymmetries that vary as a function of spatial location; all participants were faster for stimuli presented along the horizontal than for those presented along the vertical meridian and for those presented at the lower rather than at the upper locations within the vertical meridian. These results indicate that the practice of these martial arts is an effective way of counteracting the processing speed decline of visual stimuli appearing at any visual location and speed.

  15. Visual and efficient immunosensor technique for advancing biomedical applications of quantum dots on Salmonella detection and isolation

    Science.gov (United States)

    Tang, Feng; Pang, Dai-Wen; Chen, Zhi; Shao, Jian-Bo; Xiong, Ling-Hong; Xiang, Yan-Ping; Xiong, Yan; Wu, Kai; Ai, Hong-Wu; Zhang, Hui; Zheng, Xiao-Li; Lv, Jing-Rui; Liu, Wei-Yong; Hu, Hong-Bing; Mei, Hong; Zhang, Zhen; Sun, Hong; Xiang, Yun; Sun, Zi-Yong

    2016-02-01

    It is a great challenge in nanotechnology for fluorescent nanobioprobes to be applied to visually detect and directly isolate pathogens in situ. A novel and visual immunosensor technique for efficient detection and isolation of Salmonella was established here by applying fluorescent nanobioprobes on a specially-designed cellulose-based swab (a solid-phase enrichment system). The selective and chromogenic medium used on this swab can achieve the ultrasensitive amplification of target bacteria and form chromogenic colonies in situ based on a simple biochemical reaction. More importantly, because this swab can serve as an attachment site for the targeted pathogens to immobilize and immunologically capture nanobioprobes, our mAb-conjugated QD bioprobes were successfully applied on the solid-phase enrichment system to capture the fluorescence of targeted colonies under a designed excitation light instrument based on blue light-emitting diodes combined with stereomicroscopy or laser scanning confocal microscopy. Compared with the traditional methods using 4-7 days to isolate Salmonella from the bacterial mixture, this method took only 2 days to do this, and the process of initial screening and preliminary diagnosis can be completed in only one and a half days. Furthermore, the limit of detection can reach as low as 101 cells per mL Salmonella on the background of 105 cells per mL non-Salmonella (Escherichia coli, Proteus mirabilis or Citrobacter freundii, respectively) in experimental samples, and even in human anal ones. The visual and efficient immunosensor technique may be proved to be a favorable alternative for screening and isolating Salmonella in a large number of samples related to public health surveillance.It is a great challenge in nanotechnology for fluorescent nanobioprobes to be applied to visually detect and directly isolate pathogens in situ. A novel and visual immunosensor technique for efficient detection and isolation of Salmonella was established here

  16. Communicative interactions improve visual detection of biological motion.

    Directory of Open Access Journals (Sweden)

    Valeria Manera

    Full Text Available BACKGROUND: In the context of interacting activities requiring close-body contact such as fighting or dancing, the actions of one agent can be used to predict the actions of the second agent. In the present study, we investigated whether interpersonal predictive coding extends to interactive activities--such as communicative interactions--in which no physical contingency is implied between the movements of the interacting individuals. METHODOLOGY/PRINCIPAL FINDINGS: Participants observed point-light displays of two agents (A and B performing separate actions. In the communicative condition, the action performed by agent B responded to a communicative gesture performed by agent A. In the individual condition, agent A's communicative action was substituted with a non-communicative action. Using a simultaneous masking detection task, we demonstrate that observing the communicative gesture performed by agent A enhanced visual discrimination of agent B. CONCLUSIONS/SIGNIFICANCE: Our finding complements and extends previous evidence for interpersonal predictive coding, suggesting that the communicative gestures of one agent can serve as a predictor for the expected actions of the respondent, even if no physical contact between agents is implied.

  17. Clinical relevance of studies on the accuracy of visual inspection for detecting caries lesions

    DEFF Research Database (Denmark)

    Gimenez, Thais; Piovesan, Chaiana; Braga, Mariana M

    2015-01-01

    Although visual inspection is the most commonly used method for caries detection, and consequently the most investigated, studies have not been concerned about the clinical relevance of this procedure. Therefore, we conducted a systematic review in order to perform a critical evaluation considering...... the clinical relevance and methodological quality of studies on the accuracy of visual inspection for assessing caries lesions. Two independent reviewers searched several databases through July 2013 to identify papers/articles published in English. Other sources were checked to identify unpublished literature...... to clinical relevance and the methodological quality of the studies were evaluated. 96 of the 5,578 articles initially identified met the inclusion criteria. In general, most studies failed in considering some clinically relevant aspects: only 1 included study validated activity status of lesions, no study...

  18. Peripheral refraction in normal infant rhesus monkeys

    Science.gov (United States)

    Hung, Li-Fang; Ramamirtham, Ramkumar; Huang, Juan; Qiao-Grider, Ying; Smith, Earl L.

    2008-01-01

    Purpose To characterize peripheral refractions in infant monkeys. Methods Cross-sectional data for horizontal refractions were obtained from 58 normal rhesus monkeys at 3 weeks of age. Longitudinal data were obtained for both the vertical and horizontal meridians from 17 monkeys. Refractive errors were measured by retinoscopy along the pupillary axis and at eccentricities of 15, 30, and 45 degrees. Axial dimensions and corneal power were measured by ultrasonography and keratometry, respectively. Results In infant monkeys, the degree of radial astigmatism increased symmetrically with eccentricity in all meridians. There were, however, initial nasal-temporal and superior-inferior asymmetries in the spherical-equivalent refractive errors. Specifically, the refractions in the temporal and superior fields were similar to the central ametropia, but the refractions in the nasal and inferior fields were more myopic than the central ametropia and the relative nasal field myopia increased with the degree of central hyperopia. With age, the degree of radial astigmatism decreased in all meridians and the refractions became more symmetrical along both the horizontal and vertical meridians; small degrees of relative myopia were evident in all fields. Conclusions As in adult humans, refractive error varied as a function of eccentricity in infant monkeys and the pattern of peripheral refraction varied with the central refractive error. With age, emmetropization occurred for both central and peripheral refractive errors resulting in similar refractions across the central 45 degrees of the visual field, which may reflect the actions of vision-dependent, growth-control mechanisms operating over a wide area of the posterior globe. PMID:18487366

  19. Peripheral vision benefits spatial learning by guiding eye movements.

    Science.gov (United States)

    Yamamoto, Naohide; Philbeck, John W

    2013-01-01

    The loss of peripheral vision impairs spatial learning and navigation. However, the mechanisms underlying these impairments remain poorly understood. One advantage of having peripheral vision is that objects in an environment are easily detected and readily foveated via eye movements. The present study examined this potential benefit of peripheral vision by investigating whether competent performance in spatial learning requires effective eye movements. In Experiment 1, participants learned room-sized spatial layouts with or without restriction on direct eye movements to objects. Eye movements were restricted by having participants view the objects through small apertures in front of their eyes. Results showed that impeding effective eye movements made subsequent retrieval of spatial memory slower and less accurate. The small apertures also occluded much of the environmental surroundings, but the importance of this kind of occlusion was ruled out in Experiment 2 by showing that participants exhibited intact learning of the same spatial layouts when luminescent objects were viewed in an otherwise dark room. Together, these findings suggest that one of the roles of peripheral vision in spatial learning is to guide eye movements, highlighting the importance of spatial information derived from eye movements for learning environmental layouts.

  20. The effects of virtual reality displays on visual attention and detection of signals performance for main control room training

    International Nuclear Information System (INIS)

    Lin Shiaufeng; Lin Chiuhsiang Joe; Wang Rouwen; Yang Lichen; Yang Chihwei; Cheng Tsungchieh; Wang Jyhgang

    2011-01-01

    The nuclear power plant (NPP) mainly serve the purpose to provide low-cost and stable electricity for the people, but this purpose must be dependent upon the premise of 'safety first.' The reason for this is that the occurrence of nuclear power plant accidents could cause catastrophic damage to the people, property, society, and the environment. Therefore, training in superior and high reliability system is very important in accident prevention. In recent years, the Virtual Reality (VR) technology advances very fast as well as the technology for e-learning environment. VR systems have been applied for education, safety training of NPP and flying simulators. In particular, VR is an interactive and reactive technology; it allows users to interact and navigate with objects in the virtual environment. Development of VR and simulation techniques contributes to an accurate and immersive training environment for NPP operators. Main Control Room (MCR) training simulator based on VR is a more cost effective and efficient alternative to traditional simulator based training methods. The VR simulation for MCR training is a complex task. Since VR not only reinforces the visual presentation of the training materials but also provides ways to interact with the training system, it becomes more flexible and possibly more powerful in the training system. In the VR training system, the MCR operators may use just one display to view the wide range of the real world displays. The field of view (FOV) will be different from the real MCR environment in which many displays exist for the operators to view. Thus operator's immersion and visual attention will be reduced. This is the problem of MCR virtual training compared with the traditional simulator based training systems. Therefore, improving the operator's visual attention and the detection of signals in VR training system is a very important issue. This investigation intends to contribute in assessing benefits of visual attention and

  1. Routine detection of Epstein-Barr virus specific T-cells in the peripheral blood by flow cytometry

    Science.gov (United States)

    Crucian, B. E.; Stowe, R. P.; Pierson, D. L.; Sams, C. F.

    2001-01-01

    The ability to detect cytomegalovirus-specific T-cells (CD4(+)) in the peripheral blood by flow cytometry has been recently described by Picker et al. In this method, cells are incubated with viral antigen and responding (cytokine producing) T-cells are then identified by flow cytometry. To date, this technique has not been reliably used to detect Epstein-Barr virus (EBV)-specific T-cells primarily due to the superantigen/mitogenic properties of the virus which non-specifically activate T-cells. By modifying culture conditions under which the antigens are presented, we have overcome this limitation and developed an assay to detect and quantitate EBV-specific T-cells. The detection of cytokine producing T-cells by flow cytometry requires an extremely strong signal (such as culture in the presence of PMA and ionomycin). Our data indicate that in modified culture conditions (early removal of viral antigen) the non-specific activation of T-cells by EBV is reduced, but antigen presentation will continue uninhibited. Using this method, EBV-specific T-cells may be legitimately detected using flow cytometry. No reduction in the numbers of antigen-specific T-cells was observed by the early removal of target antigen when verified using cytomegalovirus antigen (a virus with no non-specific T-cell activation properties). In EBV-seropositive individuals, the phenotype of the EBV-specific cytokine producing T-cells was evaluated using four-color flow cytometry and found to be CD45(+), CD3(+), CD4(+), CD45RA(-), CD69(+), CD25(-). This phenotype indicates the stimulation of circulating previously unactivated memory T-cells. No cytokine production was observed in CD4(+) T-cells from EBV-seronegative individuals, confirming the specificity of this assay. In addition, the use of four color cytometry (CD45, CD3, CD69, IFNgamma/IL-2) allows the total quantitative assessment of EBV-specific T-cells while monitoring the interference of EBV non-specific mitogenic activity. This method may

  2. Peripheral reactions

    International Nuclear Information System (INIS)

    Greiner, D.

    1978-01-01

    Peripheral collisions, that is, collisions involving a small amount of overlap of nuclear matter, are discussed including inclusive interactions, the magnitude of the peripheral cross section, fragmentation, a compilation of experiments and available data, limiting fragmentation, factorization, some models, fragment momentum distributions, and future research directions

  3. Statin use and peripheral sensory perception: a pilot study.

    Science.gov (United States)

    West, Brenton; Williams, Cylie M; Jilbert, Elise; James, Alicia M; Haines, Terry P

    2014-06-01

    Peripheral sensory neuropathy is a neurological deficit resulting in decreased detection of sensation through the peripheral nervous system. Peripheral sensory neuropathy is commonly diagnosed with the use of a monofilament and either a tuning fork or neurothesiometer. Statins are a widely used medication and there has been some debate of association with their use and peripheral sensory neuropathy. This pilot study aimed to test the sensory perception of participants with long-term statin use and compare these results to their peers who were not taking statins. Thirty participants were recruited and equally divided into a statin and non-statin group. Healthy participants were screened by their medical and medication history, Australian Type 2 Diabetes Risk assessment, and random blood glucose level. An assessor who was blinded to the participant group conducted sensory assessments using a 10 g monofilament and neurothesiometer. There was no difference in monofilament testing results between the groups. The statin group was less sensate at the styloid process (p = 0.031) and medial malleolus (p = 0.003) than the control group. Results at the hallux were not statistically significant (p = 0.183). This result is suggestive of a potential association between long-term statin use and a decrease in peripheral sensory perception. This may be because of peripheral sensory neuropathy. Limitations such as consideration of participant height, participant numbers, and inability to analyze results against statin groups are reported. As statins are a life-saving medication, careful consideration should be applied to these results and further research be conducted to determine if these results are applicable to larger populations.

  4. The validity of upper-limb neurodynamic tests for detecting peripheral neuropathic pain.

    Science.gov (United States)

    Nee, Robert J; Jull, Gwendolen A; Vicenzino, Bill; Coppieters, Michel W

    2012-05-01

    The validity of upper-limb neurodynamic tests (ULNTs) for detecting peripheral neuropathic pain (PNP) was assessed by reviewing the evidence on plausibility, the definition of a positive test, reliability, and concurrent validity. Evidence was identified by a structured search for peer-reviewed articles published in English before May 2011. The quality of concurrent validity studies was assessed with the Quality Assessment of Diagnostic Accuracy Studies tool, where appropriate. Biomechanical and experimental pain data support the plausibility of ULNTs. Evidence suggests that a positive ULNT should at least partially reproduce the patient's symptoms and that structural differentiation should change these symptoms. Data indicate that this definition of a positive ULNT is reliable when used clinically. Limited evidence suggests that the median nerve test, but not the radial nerve test, helps determine whether a patient has cervical radiculopathy. The median nerve test does not help diagnose carpal tunnel syndrome. These findings should be interpreted cautiously, because diagnostic accuracy might have been distorted by the investigators' definitions of a positive ULNT. Furthermore, patients with PNP who presented with increased nerve mechanosensitivity rather than conduction loss might have been incorrectly classified by electrophysiological reference standards as not having PNP. The only evidence for concurrent validity of the ulnar nerve test was a case study on cubital tunnel syndrome. We recommend that researchers develop more comprehensive reference standards for PNP to accurately assess the concurrent validity of ULNTs and continue investigating the predictive validity of ULNTs for prognosis or treatment response.

  5. Contrast and Strength of Visual Memory and Imagery Differentially Affect Visual Perception

    OpenAIRE

    Saad, Elyana; Silvanto, Juha

    2013-01-01

    Visual short-term memory (VSTM) and visual imagery have been shown to modulate visual perception. However, how the subjective experience of VSTM/imagery and its contrast modulate this process has not been investigated. We addressed this issue by asking participants to detect brief masked targets while they were engaged either in VSTM or visual imagery. Subjective experience of memory/imagery (strength scale), and the visual contrast of the memory/mental image (contrast scale) were assessed on...

  6. Visual detection and microplate assay for Staphylococcus aureus based on aptamer recognition coupled to tyramine signal amplification

    International Nuclear Information System (INIS)

    Yuan, Jinglei; Li, Can; Ma, Xiaoyuan; Xia, Yu; Chen, Jie; Wang, Zhouping; Yu, Ye

    2014-01-01

    We have developed a specific method for the visual detection of Staphylococcus aureus based on aptamer recognition coupled to tyramine signal amplification technology. A biotinylated aptamer specific for S. aureus was immobilized on the surface of the wells of a microplate via biotin-avidin binding. Then, the target bacteria (S. aureus), the biotinylated-aptamer-streptavidin-HRP conjugates, biotinylated tyramine, hydrogen peroxide and streptavidin-HRP were successively placed in the wells of the microplate. After adding TMB reagent and stop solution, the intensity of the yellow reaction product can be visually inspected or measured with a plate reader. Under optimized conditions, there is a linear relationship between absorbance at 450 nm and the concentration of S. aureus in the 10 to 107 cfu mL −1 concentration range (with an R 2 of 0.9976). The limit of detection is 8 cfu mL −1 . (author)

  7. Glaucoma Diagnostic Capabilities of Foveal Avascular Zone Parameters Using Optical Coherence Tomography Angiography According to Visual Field Defect Location.

    Science.gov (United States)

    Kwon, Junki; Choi, Jaewan; Shin, Joong Won; Lee, Jiyun; Kook, Michael S

    2017-12-01

    To assess the diagnostic ability of foveal avascular zone (FAZ) parameters to discriminate glaucomatous eyes with visual field defects (VFDs) in different locations (central vs. peripheral) from normal eyes. Totally, 125 participants were separated into 3 groups: normal (n=45), glaucoma with peripheral VFD (PVFD, n=45), and glaucoma with central VFD (CVFD, n=35). The FAZ area, perimeter, and circularity and parafoveal vessel density were calculated from optical coherence tomography angiography images. The diagnostic ability of the FAZ parameters and other structural parameters was determined according to glaucomatous VFD location. Associations between the FAZ parameters and central visual function were evaluated. A larger FAZ area and longer FAZ perimeter were observed in the CVFD group than in the PVFD and normal groups. The FAZ area, perimeter, and circularity were better in differentiating glaucomatous eyes with CVFDs from normal eyes [areas under the receiver operating characteristic curves (AUC), 0.78 to 0.88] than in differentiating PVFDs from normal eyes (AUC, 0.51 to 0.64). The FAZ perimeter had a similar AUC value to the circumpapillary retinal nerve fiber layer and macular ganglion cell-inner plexiform layer thickness for differentiating eyes with CVFDs from normal eyes (all P>0.05, the DeLong test). The FAZ area was significantly correlated with central visual function (β=-112.7, P=0.035, multivariate linear regression). The FAZ perimeter had good diagnostic capability in differentiating glaucomatous eyes with CVFDs from normal eyes, and may be a potential diagnostic biomarker for detecting glaucomatous patients with CVFDs.

  8. Role of peripheral blood mononuclear cell transportation from mother to baby in HBV intrauterine infection.

    Science.gov (United States)

    Shao, Qingliang; Zhao, Xiaxia; Yao Li, M D

    2013-12-01

    We aimed to investigate the role of peripheral blood mononuclear cell transportation from mother to baby in hepatitis B virus (HBV) intrauterine infection. Thirty HBsAg-positive pregnant women in the second trimester and their aborted fetuses were included in this study. Enzyme-linked-immunosorbent-assay was utilized to detect HBsAg in the peripheral blood of pregnant women and the femoral vein blood of their aborted fetuses. HBV-DNA in serum and peripheral blood mononuclear cells (PBMC) and GSTM1 alleles of pregnant women and their aborted fetuses were detected by nested polymerase chain reaction (PCR) and seminested PCR, respectively. We also examined the location of placenta HBsAg and HBcAb using immunohistochemical staining. The expression of placenta HBV-DNA was detected by in situ hybridization. For the 30 aborted fetuses, the HBV intrauterine infection rate was 43.33%. The HBV-positive rates of HBsAg in peripheral blood, serum, and PBMC were 10% (3/30), 23.33% (7/30), and 33.33% (10/30), respectively. Maternal-fetal PBMC transport was significantly positively correlated with fetal PBMC HBV-DNA (P = 0.004). Meanwhile, the rates of HBV infection gradually decreased from the maternal side to the fetus side of placenta (decidual cells > trophoblastic cells > villous mesenchymal cells > villous capillary endothelial cells). However, no significant correlation between placenta HBV infection and HBV intrauterine infection was observed (P = 0.410). HBV intrauterine infection was primarily due to peripheral blood mononuclear cell maternal-fetal transportation in the second trimester in pregnant women.

  9. Peripheral i.v. analysis (PIVA) of venous waveforms for volume assessment in patients undergoing haemodialysis.

    Science.gov (United States)

    Hocking, K M; Alvis, B D; Baudenbacher, F; Boyer, R; Brophy, C M; Beer, I; Eagle, S

    2017-12-01

    The assessment of intravascular volume status remains a challenge for clinicians. Peripheral i.v. analysis (PIVA) is a method for analysing the peripheral venous waveform that has been used to monitor volume status. We present a proof-of-concept study for evaluating the efficacy of PIVA in detecting changes in fluid volume. We enrolled 37 hospitalized patients undergoing haemodialysis (HD) as a controlled model for intravascular volume loss. Respiratory rate (F0) and pulse rate (F1) frequencies were measured. PIVA signal was obtained by fast Fourier analysis of the venous waveform followed by weighing the magnitude of the amplitude of the pulse rate frequency. PIVA was compared with peripheral venous pressure and standard monitoring of vital signs. Regression analysis showed a linear correlation between volume loss and change in the PIVA signal (R2=0.77). Receiver operator curves demonstrated that the PIVA signal showed an area under the curve of 0.89 for detection of 20 ml kg-1 change in volume. There was no correlation between volume loss and peripheral venous pressure, blood pressure or pulse rate. PIVA-derived pulse rate and respiratory rate were consistent with similar numbers derived from the bio-impedance and electrical signals from the electrocardiogram. PIVA is a minimally invasive, novel modality for detecting changes in fluid volume status, respiratory rate and pulse rate in spontaneously breathing patients with peripheral i.v. cannulas. © The Author 2017. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  10. Detecting obstructive sleep apnea in children by self-affine visualization of oximetry.

    Science.gov (United States)

    Garde, Ainara; Dekhordi, Parastoo; Petersen, Christian L; Ansermino, J Mark; Dumont, Guy A

    2017-07-01

    Obstructive sleep apnea (OSA), characterized by cessations of breathing during sleep due to upper airway collapse, can affect the healthy growth and development of children. The gold standard for OSA diagnosis, polysomnography(PSG), is expensive and resource intensive, resulting in long waiting lists to perform a PSG. Previously, we investigated the time-frequency analysis of blood oxygen saturation (SpO 2 ) to screen for OSA. We used overnight pulse oximetry from 146 children, collected using a smartphone-based pulse oximeter (Phone Oximeter), simultaneously with standard PSG. Sleep technicians manually scored PSG and provided the average of apnea/hypoapnea events per hour (AHI). In this study, we proposed an alternative method for analyzing SpO 2 , in which a set of contracting transformations form a self-affine set with a 2D attractor, previously developed for qualitative visualization of the photoplethysmogram and electroencephalogram. We applied this technique to the overnight SpO 2 signal from individual patients and extracted features based on the distribution of points (radius and angle) in the visualization. The cloud of points in children without OSA (NonOSA) was more confined than in children with OSA, which was reflected by more empty pixels (radius and angles). The maximum value, skewness and standard deviation of the distribution of points located at different radius and angles were significantly (Bonferroni corrected) higher in NonOSA compared to OSA children. To detect OSA defined at different levels (AHI≥5, AHI≥10 and AHI≥15), three multivariate logistic regression models were implemented using a stepwise feature selection and internally validated through bootstrapping. The models (AHI≥5, AHI≥10, AHI≥15), consisting of 3, 4 and 1 features respectively, provided a bootstrap-corrected AUC of 73%, 81%, 73%. Thus, applying this visualization to nocturnal SpO 2 could yield both visual and quantitative information that might be useful for

  11. A Precise Visual Method for Narrow Butt Detection in Specular Reflection Workpiece Welding

    Directory of Open Access Journals (Sweden)

    Jinle Zeng

    2016-09-01

    Full Text Available During the complex path workpiece welding, it is important to keep the welding torch aligned with the groove center using a visual seam detection method, so that the deviation between the torch and the groove can be corrected automatically. However, when detecting the narrow butt of a specular reflection workpiece, the existing methods may fail because of the extremely small groove width and the poor imaging quality. This paper proposes a novel detection method to solve these issues. We design a uniform surface light source to get high signal-to-noise ratio images against the specular reflection effect, and a double-line laser light source is used to obtain the workpiece surface equation relative to the torch. Two light sources are switched on alternately and the camera is synchronized to capture images when each light is on; then the position and pose between the torch and the groove can be obtained nearly at the same time. Experimental results show that our method can detect the groove effectively and efficiently during the welding process. The image resolution is 12.5 μm and the processing time is less than 10 ms per frame. This indicates our method can be applied to real-time narrow butt detection during high-speed welding process.

  12. Influence of 'optical illusion' on the detectability of pneumothorax in diagnosis for chest CT images. Substantiation by visual psychological simulation images

    International Nuclear Information System (INIS)

    Henmi, Shuichi

    2008-01-01

    Some cases have been reported in which an optical illusion of lightness perception influences the detectability in diagnosis of low-density hematoma in head CT images in addition to the visual impression of the photographic density of the brain. Therefore, in this study, the author attempted to compare the detectability in diagnosis for chest images with pneumothorax using visual subjective evaluation, and investigated the influence of optical illusion on that detectability in diagnosis. Results indicated that in the window setting of lung, on such an occasion when the low-absorption free space with pneumothorax forms a crescent or the reduced lung borders on the chest-wall, an optical illusion in which the visual impression on the difference of the film contrast between the lung and the low-absorption free space with pneumothorax was psychologically emphasized when contrast was observed. In all cases the detectability in diagnosis for original images with the white thorax and mediastinum was superior to virtual images. Further, in case of the virtual double window setting of lung, thorax, and mediastinum, under the influence of the difference in the radiological anatomy of thorax and mediastinum as a result of the grouping theories of lightness computation, an optical illusion different from the original images was observed. (author)

  13. Individual differences in the radiosensitivity of hematopoietic progenitor cells detected in steady-state human peripheral blood

    International Nuclear Information System (INIS)

    Oriya, Asami; Takahashi, Kenji; Kashiwakura, Ikuo; Inanami, Osamu; Kuwabara, Mikinori; Miura, Toshiaki; Abe, Yoshinao

    2008-01-01

    The aim of this study is to evaluate the individual differences in radiosensitivity of lineage-committed myeloid hematopoietic progenitors, colony-forming cells (CFC), detected in steady-state human peripheral blood (PB). Mononuclear cells were prepared from the buffy-coat of 30 individuals PB, and were assayed for CFC by semi-solid culture supplemented with cytokines. X irradiation was performed in the range of 0.5-4 Gy at a dose rate of about 80 cGy/min. The mean number of hematopoietic progenitor cells is 5866±3408 in 1 ml of buffy-coat, suggesting that the erythroid progenitor cells are the major population. The total CFC radiosensitivity parameter D 0 and n value are 1.18±0.24 and 1.89±0.98, respectively. Using a linear regression analysis, a statistically significant correlation is observed between the D 0 value and the surviving fraction at 4 Gy (r=0.611 p 0 parameter and the level of antioxidants, plasma uric acid, plasma bilirubin, and intracellular glutathione. The present study demonstrates that there are large individual differences in the radiosensitivity of hematopoietic progenitor cells as detected in steady-state human PB. These differences demonstrate almost no correlation with plasma or intracellular antioxidants. The prediction of individual differences in radiosensitivity of CFC can only be measured by 4 Gy irradiation. (author)

  14. Diversification of visual media retrieval results using saliency detection

    Science.gov (United States)

    Muratov, Oleg; Boato, Giulia; De Natale, Franesco G. B.

    2013-03-01

    Diversification of retrieval results allows for better and faster search. Recently there has been proposed different methods for diversification of image retrieval results mainly utilizing text information and techniques imported from natural language processing domain. However, images contain visual information that is impossible to describe in text and the use of visual features is inevitable. Visual saliency is information about the main object of an image implicitly included by humans while creating visual content. For this reason it is naturally to exploit this information for the task of diversification of the content. In this work we study whether visual saliency can be used for the task of diversification and propose a method for re-ranking image retrieval results using saliency. The evaluation has shown that the use of saliency information results in higher diversity of retrieval results.

  15. Peripheral Developing Odontoma or Peripheral Ameloblastic Fibroodontoma: A Rare Challenging Case

    Directory of Open Access Journals (Sweden)

    Saede Atarbashi Moghadam

    2016-01-01

    Full Text Available Peripheral odontogenic lesions are considered to be rare within the classification of odontogenic tumors. They share the same microscopic characteristics of their central counterparts. Here, we report an ulcerated mass of the maxillary gingiva that on histopathological examination was diagnosed as peripheral developing odontoma or peripheral ameloblastic fibroodontoma. The diagnosis of this tumor is challenging and may lead to unnecessary treatment.

  16. Visual search of Mooney faces

    Directory of Open Access Journals (Sweden)

    Jessica Emeline Goold

    2016-02-01

    Full Text Available Faces spontaneously capture attention. However, which special attributes of a face underlie this effect are unclear. To address this question, we investigate how gist information, specific visual properties and differing amounts of experience with faces affect the time required to detect a face. Three visual search experiments were conducted investigating the rapidness of human observers to detect Mooney face images. Mooney images are two-toned, ambiguous images. They were used in order to have stimuli that maintain gist information but limit low-level image properties. Results from the experiments show: 1 although upright Mooney faces were searched inefficiently, they were detected more rapidly than inverted Mooney face targets, demonstrating the important role of gist information in guiding attention towards a face. 2 Several specific Mooney face identities were searched efficiently while others were not, suggesting the involvement of specific visual properties in face detection. 3 By providing participants with unambiguous gray-scale versions of the Mooney face targets prior to the visual search task, the targets were detected significantly more efficiently, suggesting that prior experience with Mooney faces improves the ability to extract gist information for rapid face detection. However, a week of training with Mooney face categorization did not lead to even more efficient visual search of Mooney face targets. In summary, these results reveal that specific local image properties cannot account for how faces capture attention. On the other hand, gist information alone cannot account for how faces capture attention either. Prior experience facilitates the effect of gist on visual search of faces, making faces a special object category for guiding attention.

  17. PET-scan shows peripherally increased neurokinin 1 receptor availability in chronic tennis elbow: visualizing neurogenic inflammation?

    Directory of Open Access Journals (Sweden)

    Magnus Peterson

    Full Text Available In response to pain, neurokinin 1 (NK1 receptor availability is altered in the central nervous system. The NK1 receptor and its primary agonist, substance P, also play a crucial role in peripheral tissue in response to pain, as part of neurogenic inflammation. However, little is known about alterations in NK1 receptor availability in peripheral tissue in chronic pain conditions and very few studies have been performed on human beings. Ten subjects with chronic tennis elbow were therefore examined by positron emission tomography (PET with the NK1 specific radioligand [(11C]GR205171 before and after treatment with graded exercise. The radioligand signal intensity was higher in the affected arm as compared with the unaffected arm, measured as differences between the arms in volume of voxels and signal intensity of this volume above a reference threshold set as 2.5 SD above mean signal intensity of the unaffected arm before treatment. In the eight subjects examined after treatment, pain ratings decreased in all subjects but signal intensity decreased in five and increased in three. In conclusion, NK1 receptors may be activated, or up-regulated in the peripheral, painful tissue of a chronic pain condition. This up-regulation does, however, have moderate correlation to pain ratings. The increased NK1 receptor availability is interpreted as part of ongoing neurogenic inflammation and may have correlation to the pathogenesis of chronic tennis elbow.ClinicalTrials.gov NCT00888225 http://clinicaltrials.gov/

  18. Peripheral Neuropathy and Agent Orange

    Science.gov (United States)

    ... Enter ZIP code here Enter ZIP code here Peripheral Neuropathy and Agent Orange VA presumes Veterans' early-onset ... 10 percent disabling by VA's rating regulations. About peripheral neuropathy Peripheral neuropathy is a condition of the peripheral ...

  19. Low cost thermal camera for use in preclinical detection of diabetic peripheral neuropathy in primary care setting

    Science.gov (United States)

    Joshi, V.; Manivannan, N.; Jarry, Z.; Carmichael, J.; Vahtel, M.; Zamora, G.; Calder, C.; Simon, J.; Burge, M.; Soliz, P.

    2018-02-01

    Diabetic peripheral neuropathy (DPN) accounts for around 73,000 lower-limb amputations annually in the US on patients with diabetes. Early detection of DPN is critical. Current clinical methods for diagnosing DPN are subjective and effective only at later stages. Until recently, thermal cameras used for medical imaging have been expensive and hence prohibitive to be installed in primary care setting. The objective of this study is to compare results from a low-cost thermal camera with a high-end thermal camera used in screening for DPN. Thermal imaging has demonstrated changes in microvascular function that correlates with nerve function affected by DPN. The limitations for using low-cost cameras for DPN imaging are: less resolution (active pixels), frame rate, thermal sensitivity etc. We integrated two FLIR Lepton (80x60 active pixels, 50° HFOV, thermal sensitivity aged 35-76) were recruited. Difference in the temperature measurements between cameras was calculated for each subject and the results show that the difference between the temperature measurements of two cameras (mean difference=0.4, p-value=0.2) is not statistically significant. We conclude that the low-cost thermal camera system shows potential for use in detecting early-signs of DPN in under-served and rural clinics.

  20. Simultaneous analysis of the expression of 14 genes with individual prognostic value in myelodysplastic syndrome patients at diagnosis: WT1 detection in peripheral blood adversely affects survival.

    Science.gov (United States)

    Santamaría, Carlos; Ramos, Fernando; Puig, Noemi; Barragán, Eva; de Paz, Raquel; Pedro, Carme; Insunza, Andrés; Tormo, Mar; Del Cañizo, Consuelo; Diez-Campelo, María; Xicoy, Blanca; Salido, Eduardo; Sánchez del Real, Javier; Hernández, Montserrat; Chillón, Carmen; Sanz, Guillermo F; García-Sanz, Ramón; San Miguel, Jesús F; González, Marcos

    2012-12-01

    Several studies have evaluated the prognostic value of the individual expression of certain genes in patients with myelodysplastic syndromes (MDS). However, none of them includes their simultaneous analysis by quantitative polymerase chain reaction (PCR). We evaluated relative expression levels of 14 molecular markers in 193 peripheral blood samples from untreated MDS patients using real-time PCR. Detectable WT1 expression levels, low TET2, and low IER3 gene expression were the only markers showing in univariate analysis a poor prognostic value for all treatment-free (TFS), progression-free (PFS), and overall survival (OS). In multivariate analysis, molecular parameters associated with a shorter TFS were: WT1 detection (p = 0.014), low TET2 (p = 0.002), and low IER3 expression (p = 0.025). WT1 detection (p = 0.006) and low TET2 (p = 0.006) expression were associated with a shorter PFS when multivariate analysis was carried out by including only molecular markers. Molecular values with an independent value in OS were: WT1 detection (p = 0.003), high EVI1 expression (p = 0.001), and undetectatable p15-CDKN2B (p = 0.037). WT1 expressers were associated with adverse clinical-biological features, high IPSS and WPSS scoring, and unfavorable molecular expression profile. In summary, detectable WT1 expression levels, and low TET2 and low IER3 expression in peripheral blood showed a strong association with adverse prognosis in MDS patients at diagnosis. However, WT1 was the only molecular marker displaying an independent prognostic value in both OS and TFS.

  1. The DNA damage of high doses of X-ray on human peripheral blood nucleated cell's and sperm

    International Nuclear Information System (INIS)

    Wang Hui; Zoulian; Jiang Qisheng; Li Fengsheng; He Rui; Song Xiujun

    2011-01-01

    Objective: To detect the DNA damage of high doses of X-ray on human peripheral blood nucleated cell's and sperm by single cell gel electrophoresis (SCGE). Evaluation the level of DNA damage of human peripheral blood nucleated cell's and sperm after high doses of X-ray. Methods: Using human peripheral blood with normal blood routine and normal sperm,give the dose of 0 Gy, 2 Gy, 4 Gy, 6 Gy, 8 Gy, 10 Gy X-ray radiation with energy of 6MU. Detect the percentage of comet-like tail, tail length and content of DNA in tail of whole blood cell's DNA and sperm's DNA by SCGE technique in 1 hour. Results: The peripheral blood nucleated cell's and sperm's comet rate were 1.00±0.10%, 2.1±1.5%, respectively, have an evidently variance in 0 Gy group (υ=18, t=2.31>1.734, P 1.734, P 1.734, P<0.05). The peripheral blood nucleated cell's and sperm's comet rate were all 100%, 100%, have no-statistical significance in 8 Gy, 10 Gy group. Conclusion: The evidence is powerful enough. That the sperm's SCGE is more sensitive than peripheral blood nucleated cell's SCGE in reflect the X-ray damage in a certain extent (2-6 Gy). (authors)

  2. Vascular access in neonatology: peripherally inserted central catheter and peripheral venous catheter

    Directory of Open Access Journals (Sweden)

    Marcia Lienemann

    2014-04-01

    The objective of this paper is to present aspects of peripherally inserted central catheter and peripheral venous catheter, highlighting important points in choosing the type of access. For the passage of peripherally inserted central catheter is previously performing specific course necessary, while the primary indication occurs when it is necessary to access the patient's stay for a long period of time. Whereas peripheral venipuncture is the most appropriate in cases of needing an IV line quickly and safely, for the administration of fluids, blood collection, blood transfusion and other.

  3. Comparison of Glaucoma Progression Detection by Optical Coherence Tomography and Visual Field.

    Science.gov (United States)

    Zhang, Xinbo; Dastiridou, Anna; Francis, Brian A; Tan, Ou; Varma, Rohit; Greenfield, David S; Schuman, Joel S; Huang, David

    2017-12-01

    To compare longitudinal glaucoma progression detection using optical coherence tomography (OCT) and visual field (VF). Validity assessment. We analyzed subjects with more than 4 semi-annual follow-up visits (every 6 months) in the multicenter Advanced Imaging for Glaucoma Study. Fourier-domain optical coherence tomography (OCT) was used to map the thickness of the peripapillary retinal nerve fiber layer (NFL) and ganglion cell complex (GCC). OCT-based progression detection was defined as a significant negative trend for either NFL or GCC. VF progression was reached if either the event or trend analysis reached significance. The analysis included 356 glaucoma suspect/preperimetric glaucoma (GS/PPG) eyes and 153 perimetric glaucoma (PG) eyes. Follow-up length was 54.1 ± 16.2 months for GS/PPG eyes and 56.7 ± 16.0 for PG eyes. Progression was detected in 62.1% of PG eyes and 59.8% of GS/PPG eyes by OCT, significantly (P glaucoma. While the utility of NFL declines in advanced glaucoma, GCC remains a sensitive progression detector from early to advanced stages. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Evaluation of Total Nitrite Pattern Visualization as an Improved Method for Gunshot Residue Detection and its Application to Casework Samples.

    Science.gov (United States)

    Berger, Jason; Upton, Colin; Springer, Elyah

    2018-04-23

    Visualization of nitrite residues is essential in gunshot distance determination. Current protocols for the detection of nitrites include, among other tests, the Modified Griess Test (MGT). This method is limited as nitrite residues are unstable in the environment and limited to partially burned gunpowder. Previous research demonstrated the ability of alkaline hydrolysis to convert nitrates to nitrites, allowing visualization of unburned gunpowder particles using the MGT. This is referred to as Total Nitrite Pattern Visualization (TNV). TNV techniques were modified and a study conducted to streamline the procedure outlined in the literature to maximize the efficacy of the TNV in casework, while reducing the required time from 1 h to 5 min, and enhancing effectiveness on blood-soiled samples. The TNV method was found to provide significant improvement in the ability to detect significant nitrite residues, without sacrificing efficiency, that would allow for the determination of the muzzle-to-target distance. © 2018 American Academy of Forensic Sciences.

  5. Fearful, but not angry, expressions diffuse attention to peripheral targets in an attentional blink paradigm.

    Science.gov (United States)

    Taylor, James M; Whalen, Paul J

    2014-06-01

    We previously demonstrated that fearful facial expressions implicitly facilitate memory for contextual events whereas angry facial expressions do not. The current study sought to more directly address the implicit effect of fearful expressions on attention for contextual events within a classic attentional paradigm (i.e., the attentional blink) in which memory is tested on a trial-by-trial basis, thereby providing subjects with a clear, explicit attentional strategy. Neutral faces of a single gender were presented via rapid serial visual presentation (RSVP) while bordered by four gray pound signs. Participants were told to watch for a gender change within the sequence (T1). It is critical to note that the T1 face displayed a neutral, fearful, or angry expression. Subjects were then told to detect a color change (i.e., gray to green; T2) at one of the four peripheral pound sign locations appearing after T1. This T2 color change could appear at one of six temporal positions. Complementing previous attentional blink paradigms, participants were told to respond via button press immediately when a T2 target was detected. We found that, compared with the neutral T1 faces, fearful faces significantly increased target detection ability at four of the six temporal locations (all ps enhance environmental monitoring above and beyond explicit attentional effects related to task instructions.

  6. NEGOSIASI PENERJEMAHAN VERBAL - VISUAL DESAIN GRAFIS

    Directory of Open Access Journals (Sweden)

    Moeljadi Pranata

    2000-01-01

    Full Text Available Design is commonly regarded as an act of individual creation to which both verbalization and logical analysis are only peripherally relevant. This article reviews a research study about talking design by Tomes et al (1998 which involving graphic designers and their clients. The conclusion is that talking design -- verbal and visual -- is the design itself. Comments from a design-major student give more light to the research s outputs. Abstract in Bahasa Indonesia : Desain umumnya dipandang sebagai karya ekspresi diri. Analisis logis dan penerjemahan verbal hanya dianggap relevan di permukaan saja. Artikel ini mereview kajian riset Tomes dkk. (1998 mengenai bahasan desain yang melibatkan tim desainer grafis dan kliennya. Simpulannya%2C bahasan desain ¾ verbal dan visual ¾ adalah desain itu sendiri. Artikel ini dilengkapi tanggapan mahasiswa desain terhadap hasil riset tersebut. graphic design%2C design process%2C verbal/visual communication

  7. Using task effort and pupil size to track covert shifts of visual attention independently of a pupillary light reflex.

    Science.gov (United States)

    Brocher, Andreas; Harbecke, Raphael; Graf, Tim; Memmert, Daniel; Hüttermann, Stefanie

    2018-03-07

    We tested the link between pupil size and the task effort involved in covert shifts of visual attention. The goal of this study was to establish pupil size as a marker of attentional shifting in the absence of luminance manipulations. In three experiments, participants evaluated two stimuli that were presented peripherally, appearing equidistant from and on opposite sides of eye fixation. The angle between eye fixation and the peripherally presented target stimuli varied from 12.5° to 42.5°. The evaluation of more distant stimuli led to poorer performance than did the evaluation of more proximal stimuli throughout our study, confirming that the former required more effort than the latter. In addition, in Experiment 1 we found that pupil size increased with increasing angle and that this effect could not be reduced to the operation of low-level visual processes in the task. In Experiment 2 the pupil dilated more strongly overall when participants evaluated the target stimuli, which required shifts of attention, than when they merely reported on the target's presence versus absence. Both conditions yielded larger pupils for more distant than for more proximal stimuli, however. In Experiment 3, we manipulated task difficulty more directly, by changing the contrast at which the target stimuli were presented. We replicated the results from Experiment 1 only with the high-contrast stimuli. With stimuli of low contrast, ceiling effects in pupil size were observed. Our data show that the link between task effort and pupil size can be used to track the degree to which an observer covertly shifts attention to or detects stimuli in peripheral vision.

  8. Efficacy of Tectonic Corneal Patch Graft for Progressive Peripheral Corneal Thinning

    Directory of Open Access Journals (Sweden)

    Cafer Tanrıverdio

    2014-12-01

    Full Text Available Objectives: To report the results of tectonic corneal patch graft (TCPG in patients with progressive peripheral corneal thinning (PCT. Materials and Methods: In this study, we included 8 patients who underwent TCPG for PCT or perforated corneal ulceration at Ankara Training and Research Hospital. Results: We performed TCPG in 7 patients for PCT and in 1 patient for perforated corneal ulceration. Mean age was 57.2±16.7 (38- 82 years. Postoperative follow-up time ranged from 6 to 24 months (mean 13.9±6.7. Possible etiologies leading to progressive PCT were trachoma, infectious corneal ulcer, and rheumatoid arthritis-severe dry eye in 2 patients each. Other 2 patients had a progressive PCT following ocular surgery. One of the patients with infectious corneal ulcer also had a trauma caused by a scissor. Amnion membrane transplantation was performed in 3 patients prior to TCPG. While the anatomic success was achieved in all 8 patients, best-corrected visual acuity (BCVA was 0.1 or better in 4 patients (50%. Postoperative BCVA was better than preoperative BCVA in 6 patients (75%. Local peripheral anterior synechiae developed in two eyes. Conclusion: TCPG is a useful therapeutic option in selected cases of corneal thinning and perforations because it effectively restores the integrity of the globe and allows acceptable visual results. (Turk J Ophthalmol 2014; 44: 440-4

  9. Robust lane detection and tracking using multiple visual cues under stochastic lane shape conditions

    Science.gov (United States)

    Huang, Zhi; Fan, Baozheng; Song, Xiaolin

    2018-03-01

    As one of the essential components of environment perception techniques for an intelligent vehicle, lane detection is confronted with challenges including robustness against the complicated disturbance and illumination, also adaptability to stochastic lane shapes. To overcome these issues, we proposed a robust lane detection method named classification-generation-growth-based (CGG) operator to the detected lines, whereby the linear lane markings are identified by synergizing multiple visual cues with the a priori knowledge and spatial-temporal information. According to the quality of linear lane fitting, the linear and linear-parabolic models are dynamically switched to describe the actual lane. The Kalman filter with adaptive noise covariance and the region of interests (ROI) tracking are applied to improve the robustness and efficiency. Experiments were conducted with images covering various challenging scenarios. The experimental results evaluate the effectiveness of the presented method for complicated disturbances, illumination, and stochastic lane shapes.

  10. Visual dysfunction, neurodegenerative diseases, and aging.

    Science.gov (United States)

    Jackson, Gregory R; Owsley, Cynthia

    2003-08-01

    The four most common sight-threatening conditions in older adults in North America are cataract, ARM, glaucoma, and diabetic retinopathy. Even in their moderate stages, these conditions cause visual sensory impairments and reductions in health-related quality of life, including difficulties in daily tasks and psychosocial problems. Many older adults are free from these conditions, yet still experience a variety of visual perceptual problems resulting from aging-related changes in the optics of the eye and degeneration of the visual neural pathways. These problems consist of impairments in visual acuity, contrast sensitivity, color discrimination, temporal sensitivity, motion perception, peripheral visual field sensitivity, and visual processing speed. PD causes a progressive loss of dopaminergic cells predominantly in the retina and possibly in other areas of the visual system. This retinal dopamine deficiency produces selective spatial-temporal abnormalities in retinal ganglion cell function, probably arising from altered receptive field organization in the PD retina. The cortical degeneration characteristics of AD, including neurofibrillary tangles and neuritic plaques, also are present in the visual cortical areas, especially in the visual association areas. The most prominent electrophysiologic change in AD is a delay in the P2 component of the flash VEP. Deficits in higher-order visual abilities typically are compromised in AD, including problems with visual attention, perceiving structure from motion, visual memory, visual learning, reading, and object and face perception. There have been reports of a visual variant of AD in which these types of visual problems are the initial and most prominent signs of the disease. Visual sensory impairments (e.g., contrast sensitivity or achromatopsia) also have been reported but are believed more reflective of cortical disturbances than of AD-associated optic neuropathy.

  11. Octopus vulgaris uses visual information to determine the location of its arm.

    Science.gov (United States)

    Gutnick, Tamar; Byrne, Ruth A; Hochner, Binyamin; Kuba, Michael

    2011-03-22

    Octopuses are intelligent, soft-bodied animals with keen senses that perform reliably in a variety of visual and tactile learning tasks. However, researchers have found them disappointing in that they consistently fail in operant tasks that require them to combine central nervous system reward information with visual and peripheral knowledge of the location of their arms. Wells claimed that in order to filter and integrate an abundance of multisensory inputs that might inform the animal of the position of a single arm, octopuses would need an exceptional computing mechanism, and "There is no evidence that such a system exists in Octopus, or in any other soft bodied animal." Recent electrophysiological experiments, which found no clear somatotopic organization in the higher motor centers, support this claim. We developed a three-choice maze that required an octopus to use a single arm to reach a visually marked goal compartment. Using this operant task, we show for the first time that Octopus vulgaris is capable of guiding a single arm in a complex movement to a location. Thus, we claim that octopuses can combine peripheral arm location information with visual input to control goal-directed complex movements. Copyright © 2011 Elsevier Ltd. All rights reserved.

  12. CHARACTERIZATION OF THE EFFECTS OF INHALED PERCHLOROETHYLENE ON SUSTAINED ATTENTION IN RATS PERFORMING A VISUAL SIGNAL DETECTION TASK

    Science.gov (United States)

    The aliphatic hydrocarbon perchloroethyelene (PCE) has been associated with neurobehavioral dysfunction including reduced attention in humans. The current study sought to assess the effects of inhaled PCE on sustained attention in rats performing a visual signal detection task (S...

  13. Automatic Change Detection to Facial Expressions in Adolescents: Evidence from Visual Mismatch Negativity Responses

    Directory of Open Access Journals (Sweden)

    Tongran eLiu

    2016-03-01

    Full Text Available Adolescence is a critical period for the neurodevelopment of social-emotional processing, wherein the automatic detection of changes in facial expressions is crucial for the development of interpersonal communication. Two groups of participants (an adolescent group and an adult group were recruited to complete an emotional oddball task featuring on happy and one fearful condition. The measurement of event-related potential (ERP was carried out via electroencephalography (EEG and electrooculography (EOG recording, to detect visual mismatch negativity (vMMN with regard to the automatic detection of changes in facial expressions between the two age groups. The current findings demonstrated that the adolescent group featured more negative vMMN amplitudes than the adult group in the fronto-central region during the 120-200 ms interval. During the time window of 370-450 ms, only the adult group showed better automatic processing on fearful faces than happy faces. The present study indicated that adolescents posses stronger automatic detection of changes in emotional expression relative to adults, and sheds light on the neurodevelopment of automatic processes concerning social-emotional information.

  14. [Detection of NK and NKT cells in peripheral blood of patients with cGVHD and its significance].

    Science.gov (United States)

    Zhou, Mao-Hua; Wang, Chun-Miao; Gong, Cai-Ping; Luo, Yin; Zhang, Min

    2012-10-01

    The aim of this study was to investigate the correlation of NK and NKT cells in peripheral blood of patients undergoing allogeneic hematopoietic stem cell transplantation (allo-HSCT) with chronic graft-versus-host disease (cGVHD). 64 patients undergoing allo-HSCT in Guangdong Provincial People Hospital were studied retrospectively. Among 64 cases, 21 cases were did not develop with cGVHD, 43 cases (mild 15, moderate 18, severe 10) were recorded with cGVHD. The frequency of NK and NKT cells in peripheral blood of patients were measured by flow cytometry. The counts of NK and NKT cells were measured by automatic five sort hematology cyto-analyser (LH-750). The frequency and counts of NK and NKT cells between patients with non-cGVHD and patients with different status of cGVHD were analysed. The results indicated that as compared with the non-cGVHD patients, the frequency and counts of NK cells in patients with cGVHD obviously reduced (P NKT cells were did not changed significantly. The frequency and counts of NK cells gradually decreased within the different status of cGVHD, the frequency and counts of NK cells in severe-cGVHD were significantly lower than that in mild-cGVHD. It is concluded that NK cells may play an important role in the incidence and development of cGVHD. The detection of frequency and counts of NK cells should be helpful to early diagnose cGVHD and provide valuable clues for assessing the severity of illnesses. NKT cells may have little effect on the incidence and development of cGVHD.

  15. Visualizing histopathologic deep learning classification and anomaly detection using nonlinear feature space dimensionality reduction.

    Science.gov (United States)

    Faust, Kevin; Xie, Quin; Han, Dominick; Goyle, Kartikay; Volynskaya, Zoya; Djuric, Ugljesa; Diamandis, Phedias

    2018-05-16

    There is growing interest in utilizing artificial intelligence, and particularly deep learning, for computer vision in histopathology. While accumulating studies highlight expert-level performance of convolutional neural networks (CNNs) on focused classification tasks, most studies rely on probability distribution scores with empirically defined cutoff values based on post-hoc analysis. More generalizable tools that allow humans to visualize histology-based deep learning inferences and decision making are scarce. Here, we leverage t-distributed Stochastic Neighbor Embedding (t-SNE) to reduce dimensionality and depict how CNNs organize histomorphologic information. Unique to our workflow, we develop a quantitative and transparent approach to visualizing classification decisions prior to softmax compression. By discretizing the relationships between classes on the t-SNE plot, we show we can super-impose randomly sampled regions of test images and use their distribution to render statistically-driven classifications. Therefore, in addition to providing intuitive outputs for human review, this visual approach can carry out automated and objective multi-class classifications similar to more traditional and less-transparent categorical probability distribution scores. Importantly, this novel classification approach is driven by a priori statistically defined cutoffs. It therefore serves as a generalizable classification and anomaly detection tool less reliant on post-hoc tuning. Routine incorporation of this convenient approach for quantitative visualization and error reduction in histopathology aims to accelerate early adoption of CNNs into generalized real-world applications where unanticipated and previously untrained classes are often encountered.

  16. Recent Visual Experience Shapes Visual Processing in Rats through Stimulus-Specific Adaptation and Response Enhancement.

    Science.gov (United States)

    Vinken, Kasper; Vogels, Rufin; Op de Beeck, Hans

    2017-03-20

    From an ecological point of view, it is generally suggested that the main goal of vision in rats and mice is navigation and (aerial) predator evasion [1-3]. The latter requires fast and accurate detection of a change in the visual environment. An outstanding question is whether there are mechanisms in the rodent visual system that would support and facilitate visual change detection. An experimental protocol frequently used to investigate change detection in humans is the oddball paradigm, in which a rare, unexpected stimulus is presented in a train of stimulus repetitions [4]. A popular "predictive coding" theory of cortical responses states that neural responses should decrease for expected sensory input and increase for unexpected input [5, 6]. Despite evidence for response suppression and enhancement in noninvasive scalp recordings in humans with this paradigm [7, 8], it has proven challenging to observe both phenomena in invasive action potential recordings in other animals [9-11]. During a visual oddball experiment, we recorded multi-unit spiking activity in rat primary visual cortex (V1) and latero-intermediate area (LI), which is a higher area of the rodent ventral visual stream. In rat V1, there was only evidence for response suppression related to stimulus-specific adaptation, and not for response enhancement. However, higher up in area LI, spiking activity showed clear surprise-based response enhancement in addition to stimulus-specific adaptation. These results show that neural responses along the rat ventral visual stream become increasingly sensitive to changes in the visual environment, suggesting a system specialized in the detection of unexpected events. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Visual detection of Brucella in bovine biological samples using DNA-activated gold nanoparticles.

    Directory of Open Access Journals (Sweden)

    Dheeraj Pal

    Full Text Available Brucellosis is a bacterial disease, which, although affecting cattle primarily, has been associated with human infections, making its detection an important challenge. The existing gold standard diagnosis relies on the culture of bacteria which is a lengthy and costly process, taking up to 45 days. New technologies based on molecular diagnosis have been proposed, either through dip-stick, immunological assays, which have limited specificity, or using nucleic acid tests, which enable to identify the pathogen, but are impractical for use in the field, where most of the reservoir cases are located. Here we demonstrate a new test based on hybridization assays with metal nanoparticles, which, upon detection of a specific pathogen-derived DNA sequence, yield a visual colour change. We characterise the components used in the assay with a range of analytical techniques and show sensitivities down to 1000 cfu/ml for the detection of Brucella. Finally, we demonstrate that the assay works in a range of bovine samples including semen, milk and urine, opening up the potential for its use in the field, in low-resource settings.

  18. Visually directed vs. software-based targeted biopsy compared to transperineal template mapping biopsy in the detection of clinically significant prostate cancer.

    Science.gov (United States)

    Valerio, Massimo; McCartan, Neil; Freeman, Alex; Punwani, Shonit; Emberton, Mark; Ahmed, Hashim U

    2015-10-01

    Targeted biopsy based on cognitive or software magnetic resonance imaging (MRI) to transrectal ultrasound registration seems to increase the detection rate of clinically significant prostate cancer as compared with standard biopsy. However, these strategies have not been directly compared against an accurate test yet. The aim of this study was to obtain pilot data on the diagnostic ability of visually directed targeted biopsy vs. software-based targeted biopsy, considering transperineal template mapping (TPM) biopsy as the reference test. Prospective paired cohort study included 50 consecutive men undergoing TPM with one or more visible targets detected on preoperative multiparametric MRI. Targets were contoured on the Biojet software. Patients initially underwent software-based targeted biopsies, then visually directed targeted biopsies, and finally systematic TPM. The detection rate of clinically significant disease (Gleason score ≥3+4 and/or maximum cancer core length ≥4mm) of one strategy against another was compared by 3×3 contingency tables. Secondary analyses were performed using a less stringent threshold of significance (Gleason score ≥4+3 and/or maximum cancer core length ≥6mm). Median age was 68 (interquartile range: 63-73); median prostate-specific antigen level was 7.9ng/mL (6.4-10.2). A total of 79 targets were detected with a mean of 1.6 targets per patient. Of these, 27 (34%), 28 (35%), and 24 (31%) were scored 3, 4, and 5, respectively. At a patient level, the detection rate was 32 (64%), 34 (68%), and 38 (76%) for visually directed targeted, software-based biopsy, and TPM, respectively. Combining the 2 targeted strategies would have led to detection rate of 39 (78%). At a patient level and at a target level, software-based targeted biopsy found more clinically significant diseases than did visually directed targeted biopsy, although this was not statistically significant (22% vs. 14%, P = 0.48; 51.9% vs. 44.3%, P = 0.24). Secondary

  19. Peripheral nerve hyperexcitability with preterminal nerve and neuromuscular junction remodeling is a hallmark of Schwartz-Jampel syndrome.

    Science.gov (United States)

    Bauché, Stéphanie; Boerio, Delphine; Davoine, Claire-Sophie; Bernard, Véronique; Stum, Morgane; Bureau, Cécile; Fardeau, Michel; Romero, Norma Beatriz; Fontaine, Bertrand; Koenig, Jeanine; Hantaï, Daniel; Gueguen, Antoine; Fournier, Emmanuel; Eymard, Bruno; Nicole, Sophie

    2013-12-01

    Schwartz-Jampel syndrome (SJS) is a recessive disorder with muscle hyperactivity that results from hypomorphic mutations in the perlecan gene, a basement membrane proteoglycan. Analyses done on a mouse model have suggested that SJS is a congenital form of distal peripheral nerve hyperexcitability resulting from synaptic acetylcholinesterase deficiency, nerve terminal instability with preterminal amyelination, and subtle peripheral nerve changes. We investigated one adult patient with SJS to study this statement in humans. Perlecan deficiency due to hypomorphic mutations was observed in the patient biological samples. Electroneuromyography showed normal nerve conduction, neuromuscular transmission, and compound nerve action potentials while multiple measures of peripheral nerve excitability along the nerve trunk did not detect changes. Needle electromyography detected complex repetitive discharges without any evidence for neuromuscular transmission failure. The study of muscle biopsies containing neuromuscular junctions showed well-formed post-synaptic element, synaptic acetylcholinesterase deficiency, denervation of synaptic gutters with reinnervation by terminal sprouting, and long nonmyelinated preterminal nerve segments. These data support the notion of peripheral nerve hyperexcitability in SJS, which would originate distally from synergistic actions of peripheral nerve and neuromuscular junction changes as a result of perlecan deficiency. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Detection experiments with humans implicate visual predation as a driver of colour polymorphism dynamics in pygmy grasshoppers

    Science.gov (United States)

    2013-01-01

    Background Animal colour patterns offer good model systems for studies of biodiversity and evolution of local adaptations. An increasingly popular approach to study the role of selection for camouflage for evolutionary trajectories of animal colour patterns is to present images of prey on paper or computer screens to human ‘predators’. Yet, few attempts have been made to confirm that rates of detection by humans can predict patterns of selection and evolutionary modifications of prey colour patterns in nature. In this study, we first analyzed encounters between human ‘predators’ and images of natural black, grey and striped colour morphs of the polymorphic Tetrix subulata pygmy grasshoppers presented on background images of unburnt, intermediate or completely burnt natural habitats. Next, we compared detection rates with estimates of capture probabilities and survival of free-ranging grasshoppers, and with estimates of relative morph frequencies in natural populations. Results The proportion of grasshoppers that were detected and time to detection depended on both the colour pattern of the prey and on the type of visual background. Grasshoppers were detected more often and faster on unburnt backgrounds than on 50% and 100% burnt backgrounds. Striped prey were detected less often than grey or black prey on unburnt backgrounds; grey prey were detected more often than black or striped prey on 50% burnt backgrounds; and black prey were detected less often than grey prey on 100% burnt backgrounds. Rates of detection mirrored previously reported rates of capture by humans of free-ranging grasshoppers, as well as morph specific survival in the wild. Rates of detection were also correlated with frequencies of striped, black and grey morphs in samples of T. subulata from natural populations that occupied the three habitat types used for the detection experiment. Conclusions Our findings demonstrate that crypsis is background-dependent, and implicate visual predation

  1. Brain activity during auditory and visual phonological, spatial and simple discrimination tasks.

    Science.gov (United States)

    Salo, Emma; Rinne, Teemu; Salonen, Oili; Alho, Kimmo

    2013-02-16

    We used functional magnetic resonance imaging to measure human brain activity during tasks demanding selective attention to auditory or visual stimuli delivered in concurrent streams. Auditory stimuli were syllables spoken by different voices and occurring in central or peripheral space. Visual stimuli were centrally or more peripherally presented letters in darker or lighter fonts. The participants performed a phonological, spatial or "simple" (speaker-gender or font-shade) discrimination task in either modality. Within each modality, we expected a clear distinction between brain activations related to nonspatial and spatial processing, as reported in previous studies. However, within each modality, different tasks activated largely overlapping areas in modality-specific (auditory and visual) cortices, as well as in the parietal and frontal brain regions. These overlaps may be due to effects of attention common for all three tasks within each modality or interaction of processing task-relevant features and varying task-irrelevant features in the attended-modality stimuli. Nevertheless, brain activations caused by auditory and visual phonological tasks overlapped in the left mid-lateral prefrontal cortex, while those caused by the auditory and visual spatial tasks overlapped in the inferior parietal cortex. These overlapping activations reveal areas of multimodal phonological and spatial processing. There was also some evidence for intermodal attention-related interaction. Most importantly, activity in the superior temporal sulcus elicited by unattended speech sounds was attenuated during the visual phonological task in comparison with the other visual tasks. This effect might be related to suppression of processing irrelevant speech presumably distracting the phonological task involving the letters. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Drug-induced peripheral neuropathy

    DEFF Research Database (Denmark)

    Vilholm, Ole Jakob; Christensen, Alex Alban; Zedan, Ahmed

    2014-01-01

    Peripheral neuropathy can be caused by medication, and various descriptions have been applied for this condition. In this MiniReview, the term 'drug-induced peripheral neuropathy' (DIPN) is used with the suggested definition: Damage to nerves of the peripheral nervous system caused by a chemical...... substance used in the treatment, cure, prevention or diagnosis of a disease. Optic neuropathy is included in this definition. A distinction between DIPN and other aetiologies of peripheral neuropathy is often quite difficult and thus, the aim of this MiniReview is to discuss the major agents associated...

  3. Colour Terms Affect Detection of Colour and Colour-Associated Objects Suppressed from Visual Awareness

    OpenAIRE

    Forder, Lewis; Taylor, Olivia; Mankin, Helen; Scott, Ryan B.; Franklin, Anna

    2016-01-01

    The idea that language can affect how we see the world continues to create controversy. A potentially important study in this field has shown that when an object is suppressed from visual awareness using continuous flash suppression (a form of binocular rivalry), detection of the object is differently affected by a preceding word prime depending on whether the prime matches or does not match the object. This may suggest that language can affect early stages of vision. We replicated this parad...

  4. NEGOSIASI PENERJEMAHAN VERBAL - VISUAL DESAIN GRAFIS

    OpenAIRE

    Moeljadi Pranata

    2000-01-01

    Design is commonly regarded as an act of individual creation to which both verbalization and logical analysis are only peripherally relevant. This article reviews a research study about talking design by Tomes et al (1998) which involving graphic designers and their clients. The conclusion is that talking design -- verbal and visual -- is the design itself. Comments from a design-major student give more light to the research s outputs. Abstract in Bahasa Indonesia : Desain umumnya dipandang s...

  5. VRP09 Objective Methods to Test Visual Dysfunction in the Presence of Cognitive Impairment

    Science.gov (United States)

    2014-10-01

    cortex  in response  to  visual  stimuli  in  the  central  and  peripheral...defined  damage  to  the  retina,  optic  nerve,  visual   radiations  or  visual   cortex  will  be  used  to  study...tooth  to  the  portable   processor  or  also  to  a  nearby  computer.   The  optical  head  can  be

  6. Comparison of visual versus microscopic methods to detect blood splatter from an intravascular catheter with engineered sharps injury protection.

    Science.gov (United States)

    Ansari, Aiysha; Ramaiah, Padmaja; Collazo, Lillian; Salihu, Hamisu M; Haiduven, Donna

    2013-11-01

    To determine whether retractable intravenous devices produced blood splatter and whether blood splatter frequency differed between visual and microscopy detection methods. In this laboratory-based experiment, 105 venipunctures were performed in a simulated brachial vein containing mock venous blood. The retraction mechanism was activated in a testing chamber with precut fabric filters, placed at 3 different locations, to capture blood splatter. Differences in filter mass, visual inspection, and microscopic analysis for presence of blood on filters were the units of analysis. Descriptive statistics, paired Student t tests, and κ statistics were used for data analysis. Blood splatter was detected visually and microscopically as follows: filter A, 70% and 71%, respectively; filter B, 12% and 9%, respectively; and filter C, 13% and 10%, respectively. A statistically significant difference was observed in the mean mass of filter A between before and after activation when confirmed by the naked eye (P = .014) and microscopically (P = .0092). Substantial agreement between methods was observed for filter A (κ - 0.78 [95% confidence interval, 0.64-0.92]), filter B (κ - 0.73 [95% confidence interval, 0.51-0.95]), and filter C (κ - 0.75 [95% confidence interval, 0.55-0.96]). However, blood was detected by microscopy and not by the naked eye in 7 instances (7%). Our findings demonstrate that splatter, which can potentially expose healthcare workers (HCWs) to bloodborne pathogens, is associated with the activation of intravascular catheters with retraction mechanisms. HCWs may not detect this splatter when it occurs and may not report a splash to mucous membranes or nonintact skin. The need to wear personal protective equipment when using such devices is reinforced.

  7. Evaluation of Two Different Analytical Methods for Circulating Tumor Cell Detection in Peripheral Blood of Patients with Primary Breast Cancer

    Directory of Open Access Journals (Sweden)

    B. A. S. Jaeger

    2014-01-01

    Full Text Available Background. Evidence is accumulating that circulating tumor cells (CTC out of peripheral blood can serve as prognostic marker not only in metastatic but also in early breast cancer (BC. Various methods are available to detect CTC. Comparisons between the different techniques, however, are rare. Material and Methods. We evaluate two different methods for CTC enrichment and detection in primary BC patients: the FDA-approved CellSearch System (CSS; Veridex, Warren, USA and a manual immunocytochemistry (MICC. The cut-off value for positivity was ≥1 CTC. Results. The two different nonoverlapping patient cohorts evaluated with one or the other method were well balanced regarding common clinical parameters. Before adjuvant CHT 21.1% (416 out of 1972 and 20.6% (247 out of 1198 of the patients were CTC-positive, while after CHT 22.5% (359 out of 1598 and 16.6% (177 out of 1066 of the patients were CTC-positive using CSS or MICC, respectively. CTC positivity rate before CHT was thus similar and not significantly different (P=0.749, while CTC positivity rate immediately after CHT was significantly lower using MICC compared to CSS (P<0.001. Conclusion. Using CSS or MICC for CTC detection, we found comparable prevalence of CTC before but not after adjuvant CHT.

  8. Peripheral pulmonary arteries: identification at multi-slice spiral CT with 3D reconstruction

    International Nuclear Information System (INIS)

    Coche, Emmanuel; Pawlak, Sebastien; Dechambre, Stephane; Maldague, Baudouin

    2003-01-01

    Our objective was to analyze the peripheral pulmonary arteries using thin-collimation multi-slice spiral CT. Twenty consecutive patients underwent enhanced-spiral multi-slice CT using 1-mm collimation. Two observers analyzed the pulmonary arteries by consensus on a workstation. Each artery was identified on axial and 3D shaded-surface display reconstruction images. Each subsegmental artery was measured at a mediastinal window setting and compared with anatomical classifications. The location and branching of every subsegmental artery was recorded. The number of well-visualized sub-subsegmental arteries at a mediastinal window setting was compared with those visualized at a lung window setting. Of 800 subsegmental arteries, 769 (96%) were correctly visualized and 123 accessory subsegmental arteries were identified using the mediastinal window setting. One thousand ninety-two of 2019 sub-subsegmental arteries (54%) identified using the lung window setting were correctly visualized using the mediastinal window setting. Enhanced multi-slice spiral CT with thin collimation can be used to analyze precisely the subsegmental pulmonary arteries and may identify even more distal pulmonary arteries. (orig.)

  9. F wave index: A diagnostic tool for peripheral neuropathy.

    Science.gov (United States)

    Sathya, G R; Krishnamurthy, N; Veliath, Susheela; Arulneyam, Jayanthi; Venkatachalam, J

    2017-03-01

    Each skeletal muscle is usually supplied by two or more nerve roots and if one nerve root is affected and the other is spared, the clinically used F wave minimum latency can still be normal. An F wave index was constructed taking into consideration the other parameters of the F wave such as persistence, chronodispersion, latency, arm-length to determine its usefulness in the diagnosis of peripheral neuropathy. This study was undertaken to construct the F wave index in the upper limb for the median nerve in normal healthy adult males and in patients with peripheral neuropathy and to compare the values obtained in both groups. This hospital-based study was carried out on 40 males who were diagnosed to have peripheral neuropathy and on 40 age matched healthy males who served as the control group. The F wave recording was done using a digitalized nerve conduction/electromyography/EP machine in a quiet and dimly lit room. All recordings were done between 0900 and 1100 h at an ambient temperature of 22°C. The F wave recording was obtained from a fully relaxed muscle by stimulating the median nerve. The median value for F wave index obtained from median nerve (abductor pollicis brevis) in patients with peripheral neuropathy [right arm - 35.85, interquartile range (IQR) - 35.26; left arm - 39.49, IQR - 39.49] was significantly lower (P=0.001) as compared to the control group (right arm - 102.62, IQR - 83.76; left arm - 77.43, IQR - 58.02). Our results showed that F wave index in upper limb was significantly lower in patients with peripheral neuropathy than the healthy controls, and could be used for early detection of peripheral neuropathy.

  10. GMO detection in food and feed through screening by visual loop-mediated isothermal amplification assays.

    Science.gov (United States)

    Wang, Cong; Li, Rong; Quan, Sheng; Shen, Ping; Zhang, Dabing; Shi, Jianxin; Yang, Litao

    2015-06-01

    Isothermal DNA/RNA amplification techniques are the primary methodology for developing on-spot rapid nucleic acid amplification assays, and the loop-mediated isothermal amplification (LAMP) technique has been developed and applied in the detection of foodborne pathogens, plant/animal viruses, and genetically modified (GM) food/feed contents. In this study, one set of LAMP assays targeting on eight frequently used universal elements, marker genes, and exogenous target genes, such as CaMV35S promoter, FMV35S promoter, NOS, bar, cry1Ac, CP4 epsps, pat, and NptII, were developed for visual screening of GM contents in plant-derived food samples with high efficiency and accuracy. For these eight LAMP assays, their specificity was evaluated by testing commercial GM plant events and their limits of detection were also determined, which are 10 haploid genome equivalents (HGE) for FMV35S promoter, cry1Ac, and pat assays, as well as five HGE for CaMV35S promoter, bar, NOS terminator, CP4 epsps, and NptII assays. The screening applicability of these LAMP assays was further validated successfully using practical canola, soybean, and maize samples. The results suggested that the established visual LAMP assays are applicable and cost-effective for GM screening in plant-derived food samples.

  11. Visual inspection equipment for the secondary side of steam generators. Final report

    International Nuclear Information System (INIS)

    Hinton, M.S.; Chagnon, C.W.

    1981-05-01

    The development of miniature visual examination equipment capable of inspecting regions inside the tube bundles of nuclear steam generators to determine such factors as gap condition, tube outside surface condition, and material buildup is described. Tube-to-support plate interface regions at the tenth-support plate level in a once-through steam generator (Oconee 1) were visually examined. Other areas in the peripheral region were examined for conditions associated with available eddy-current and profilometer data

  12. Application of Data Mining and Knowledge Discovery Techniques to Enhance Binary Target Detection and Decision-Making for Compromised Visual Images

    National Research Council Canada - National Science Library

    Repperger, D. W; Phillips, C. A; Schrider, C. D; Smith, E. A

    2004-01-01

    In an effort to improve decision-making on the identity of unknown objects appearing in visual images when the surrounding environment may be noisy and cluttered, a highly sensitive target detection...

  13. Role of peripheral eosinophilia in adverse cutaneous drug reactions.

    Science.gov (United States)

    Drago, F; Cogorno, L; Agnoletti, A F; Parodi, A

    2015-01-01

    The objective of this retrospective study was to verify whether peripheral eosinophilia (PE) may be a marker of severity for adverse cutaneous drug reactions (ACDR). We investigated for PE in sixty-three patients diagnosed as adverse cutaneous drug reactions. All the patients underwent blood tests at baseline visit. Only patients that showed a very likely connection between ACDR and the suspected causative drug were induced in the study. We found that 11 out of 63 patients (17%) presented PE for values ≥ 0.6 x 10(9) cells/l or for a percentage of total leukocytes ≥ 6%. These 11 patients compared to patients without eosinophilia had a longer recovery time, they showed diffuse severe cutaneous reactions and they all needed a systemic therapy compared to the 41% of patients without eosinophilia. These outcomes prompt us to believe that peripheral eosinophilia may be an index of severity for adverse cutaneous drug reactions. Therefore, we suggest physicians to always detect the presence of peripheral eosinophilia in order to not underestimate the reaction and to promptly start an appropriate therapy.

  14. Feature-Based Change Detection Reveals Inconsistent Individual Differences in Visual Working Memory Capacity.

    Science.gov (United States)

    Ambrose, Joseph P; Wijeakumar, Sobanawartiny; Buss, Aaron T; Spencer, John P

    2016-01-01

    Visual working memory (VWM) is a key cognitive system that enables people to hold visual information in mind after a stimulus has been removed and compare past and present to detect changes that have occurred. VWM is severely capacity limited to around 3-4 items, although there are robust individual differences in this limit. Importantly, these individual differences are evident in neural measures of VWM capacity. Here, we capitalized on recent work showing that capacity is lower for more complex stimulus dimension. In particular, we asked whether individual differences in capacity remain consistent if capacity is shifted by a more demanding task, and, further, whether the correspondence between behavioral and neural measures holds across a shift in VWM capacity. Participants completed a change detection (CD) task with simple colors and complex shapes in an fMRI experiment. As expected, capacity was significantly lower for the shape dimension. Moreover, there were robust individual differences in behavioral estimates of VWM capacity across dimensions. Similarly, participants with a stronger BOLD response for color also showed a strong neural response for shape within the lateral occipital cortex, intraparietal sulcus (IPS), and superior IPS. Although there were robust individual differences in the behavioral and neural measures, we found little evidence of systematic brain-behavior correlations across feature dimensions. This suggests that behavioral and neural measures of capacity provide different views onto the processes that underlie VWM and CD. Recent theoretical approaches that attempt to bridge between behavioral and neural measures are well positioned to address these findings in future work.

  15. Evaluation of Tc-99M dextran as a useful agent for peripheral lymphoscintigraphy

    International Nuclear Information System (INIS)

    Farzana Kousar; Muhammad Numair Younis; Shabana Saeed; Mustanser Jehangir; Saeeda Asghar

    2004-01-01

    Peripheral lymphoscintigraphy is known for its great academic value and more importantly, may contribute to supporting the accuracy of clinical diagnosis and assessment of lymphedema treatment. The main aim of this study was to evaluate the 99m Tc dextran as peripheral lymphoscintigraphic agent and its validation in recognizing different lymphatic patterns in normal and edematous limbs. Methods: Peripheral lymphoscintigraphy was performed in 24 patients (mean age 43.9 ± 11 years) using 99m Tc dextran (molecular weight 150,000 and 250,000) as radiotracer. 37 MBq (1 mCi) 99m Tc dextran (PINSCANTM) was injected intradermally in the first web space of the hand or foot of both limbs. 30 minutes sequential dynamic and static imaging was done. Delayed static images were taken at one hour and then three hours post injection. Results: Only qualitative interpretation was done. Different lymphatic patterns were observed in normal population as well as in control and edematous limbs. Results were further analysed using chi square test, paired and unpaired student t test at the confidence level 0.05. All mean values were given with one standard deviation. Visual and statistical analysis showed good clinical correlation. These results were also compared favourably with 99m Tc HSA lymphoscintigraphic findings available in literature. Conclusion: 99m Tc dextran is a promising agent for peripheral lymphoscintigraphy. (authors)

  16. Remote detection device and detection method therefor

    International Nuclear Information System (INIS)

    Kogure, Sumio; Yoshida, Yoji; Matsuo, Takashiro; Takehara, Hidetoshi; Kojima, Shinsaku.

    1997-01-01

    The present invention provides a non-destructive detection device for collectively, efficiently and effectively conducting maintenance and detection for confirming the integrity of a nuclear reactor by way of a shielding member for shielding radiation rays generated from an objective portion to be detected. Namely, devices for direct visual detection using an under water TV camera as a sensor, an eddy current detection using a coil as a sensor and each magnetic powder flow detection are integrated and applied collectively. Specifically, the visual detection by using the TV camera and the eddy current flaw detection are adopted together. The flaw detection with magnetic powder is applied as a means for confirming the results of the two kinds of detections by other method. With such procedures, detection techniques using respective specific theories are combined thereby enabling to enhance the accuracy for the evaluation of the detection. (I.S.)

  17. A Powerful, Cost Effective, Web Based Engineering Solution Supporting Conjunction Detection and Visual Analysis

    Science.gov (United States)

    Novak, Daniel M.; Biamonti, Davide; Gross, Jeremy; Milnes, Martin

    2013-08-01

    An innovative and visually appealing tool is presented for efficient all-vs-all conjunction analysis on a large catalogue of objects. The conjunction detection uses a nearest neighbour search algorithm, based on spatial binning and identification of pairs of objects in adjacent bins. This results in the fastest all vs all filtering the authors are aware of. The tool is constructed on a server-client architecture, where the server broadcasts to the client the conjunction data and ephemerides, while the client supports the user interface through a modern browser, without plug-in. In order to make the tool flexible and maintainable, Java software technologies were used on the server side, including Spring, Camel, ActiveMQ and CometD. The user interface and visualisation are based on the latest web technologies: HTML5, WebGL, THREE.js. Importance has been given on the ergonomics and visual appeal of the software. In fact certain design concepts have been borrowed from the gaming industry.

  18. Visual function affects prosocial behaviors in older adults.

    Science.gov (United States)

    Teoli, Dac A; Smith, Merideth D; Leys, Monique J; Jain, Priyanka; Odom, J Vernon

    2016-02-01

    Eye-related pathological conditions such as glaucoma, diabetic retinopathy, and age-related macular degeneration commonly lead to decreased peripheral/central field, decreased visual acuity, and increased functional disability. We sought to answer if relationships exist between measures of visual function and reported prosocial behaviors in an older adult population with eye-related diagnoses. The sample consisted of adults, aged ≥ 60 years old, at an academic hospital's eye institute. Vision ranged from normal to severe impairment. Medical charts determined the visual acuities, ocular disease, duration of disease (DD), and visual fields (VF). Measures of giving help were via validated questionnaires on giving formal support (GFS) and giving informal support; measures of help received were perceived support (PS) and informal support received (ISR). ISR had subscales: tangible support (ISR-T), emotional support (ISR-E), and composite (ISR-C). Visual acuities of the better and worse seeing eyes were converted to LogMAR values. VF information converted to a 4-point rating scale of binocular field loss severity. DD was in years. Among 96 participants (mean age 73.28; range 60-94), stepwise regression indicated a relationship of visual variables to GFS (p T (p prosocial behavior in older adults.

  19. Near peripheral motion contrast threshold predicts older drivers' simulator performance.

    Science.gov (United States)

    Henderson, Steven; Gagnon, Sylvain; Collin, Charles; Tabone, Ricardo; Stinchcombe, Arne

    2013-01-01

    Our group has previously demonstrated that peripheral motion contrast threshold (PMCT) is significantly associated with self-reported accident risk of older drivers (questionnaire assessment), and with Useful Field of View(®) subtest 2 (UFOV2). It has not been shown, however, that PMCT is significantly associated with driving performance. Using the method of descending limits (spatial two-alternative forced choice) we assessed motion contrast thresholds of 28 young participants (25-45), and 21 older drivers (63-86) for 0.4 cycle/degree drifting Gabor stimuli at 15° eccentricity and examined whether it was related to performance on a simulated on-road test and to a measure of visual attention (UFOV(®) subtests 2 and 3). Peripheral motion contrast thresholds (PMCT) of younger participants were significantly lower than older participants. PMCT and UFOV2 significantly predicted driving examiners' scores of older drivers' simulator performance, as well as number of crashes. Within the older group, PMCT correlated significantly with UFOV2, UFOV3, and age. Within the younger group, PMCT was not significantly related to either UFOV(®) scores or age. Partial correlations showed that: substantial association between PMCT and UFOV2 was not age-related (within the older driver group); PMCT and UFOV2 tapped a common visual function; and PMCT assessed a component not captured by UFOV2. PMCT is potentially a useful assessment tool for predicting accident risk of older drivers, and for informing efforts to develop effective countermeasures to remediate this functional deficit as much as possible. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Magnetic resonance imaging of peripheral neuropathy

    International Nuclear Information System (INIS)

    Nishiura, Yasumasa; Hara, Yuki; Yoshii, Yuichi; Kokubu, Yukihiro; Ochiai, Naoyuki; Niitsu, Mamoru

    2008-01-01

    Development of microscopy coil (MC) in MRI has accomplished high resolution imaging to observe small objects like the minute peripheral nerves and this paper describes authors' experience with the coil of peripheral neuropathy. Subjects are 15 hands of 13 female patients with idiopathic carpal tunnel syndrome (mean age, 64.2 y) and 15 hands of 15 control healthy females (52.5 y). Imaging of extending and bending digits is done with Philips 1.5 T MRI machine using 47 mm MC fixed by a sandbag through modes of T1W, T2W and T2W-fast field echo to evaluate the morphology of flexor tendon and median nerve (and its diameters and area), extension of flexor retinaculum, and area of soft carpal tunnel. It is found the MRI is useful in diagnosis of anterior interosseous neuroparalysis by seeing the morphology above and by detecting fascicles with abnormal brightness and diameter in the median nerve. Future improvement of the MRI technology is promising for progress of the diagnosis and evaluation of the pathogenesis of the disease. (R.T.)

  1. On detection and automatic tracking of butt weld line in thin wall pipe welding by a mobile robot with visual sensor

    International Nuclear Information System (INIS)

    Suga, Yasuo; Ishii, Hideaki; Muto, Akifumi

    1992-01-01

    An automatic pipe welding mobile robot system with visual sensor was constructed. The robot can move along a pipe, and detect the weld line to be welded by visual sensor. Moreover, in order to make an automatic welding, the welding torch can track the butt weld line of the pipes at a constant speed by rotating the robot head. Main results obtained are summarized as follows: 1) Using a proper lighting fixed in front of the CCD camera, the butt weld line of thin wall pipes can be recongnized stably. In this case, the root gap should be approximately 0.5 mm. 2) In order to detect the weld line stably during moving along the pipe, a brightness distribution measured by the CCD camera should be subjected to smoothing and differentiating and then the weld line is judged by the maximum and minimum values of the differentials. 3) By means of the basic robot system with a visual sensor controlled by a personal computer, the detection and in-process automatic tracking of a weld line are possible. The average tracking error was approximately 0.2 mm and maximum error 0.5 mm and the welding speed was held at a constant value with error of about 0.1 cm/min. (author)

  2. Case Report: Detection and quantification of tumor cells in peripheral blood and ascitic fluid from a metastatic esophageal cancer patient using the CellSearch® technology [v1; ref status: indexed, http://f1000r.es/2hr

    Directory of Open Access Journals (Sweden)

    Qian Tu

    2014-01-01

    Full Text Available Analysis of ascitic fluid should help to identify and characterize malignant cells in gastrointestinal cancer. However, despite a high specificity, the sensitivity of traditional ascitic fluid cytology remains insufficient, at around 60%. Since 2004 the CellSearch® technology has shown its advantages in the detection of circulating tumor cells (CTCs in peripheral blood, which can perform an accurate diagnosis and molecular analysis at the same time. To our knowledge, no previous study has explored the potential utility of this technology for the detection and quantification of tumor cells in ascitic fluid samples. Herein we report a case of metastatic esophageal adenocarcinoma in a 70-year-old man presenting with dysphagia and a large amount of fluid in the peritoneal cavity. Analysis of a peripheral blood sample and ascites sample with the CellSearch® technology both revealed the presence of putative tumor cells that were positive for epithelial cell adhesion molecule (EpCAM and cytokeratin (CK expression. This study confirmed the hematogenous dissemination of esophageal cancer by the detection of circulating tumor cells in the peripheral blood, and is the first to demonstrate that tumor cells can be identified in ascitic fluid by using CellSearch® technology.

  3. Propylthiouracil and peripheral neuropathy

    Directory of Open Access Journals (Sweden)

    Valentina Van Boekel

    1992-06-01

    Full Text Available Peripheral neuropathy is a rare manifestation in hyperthyroidism. We describe the neurological manifestations of a 38 year old female with Graves' disease who developed peripheral neuropathy in the course of her treatment with propylthiouracil. After the drug was tapered off, the neurological signs disappeared. Therefore, we call attention for a possible toxic effect on peripheral nervous system caused by this drug.

  4. Superiority of visual (verbal) vs. auditory test presentation modality in a P300-based CIT: The Complex Trial Protocol for concealed autobiographical memory detection.

    Science.gov (United States)

    Deng, Xiaohong; Rosenfeld, J Peter; Ward, Anne; Labkovsky, Elena

    2016-07-01

    This paper continues our efforts to determine which modality is best for presentation of stimuli in the P300-based concealed information test (CIT) called the Complex Trial Protocol (CTP). The first part of the CTP trial involves presentation of the key probe or irrelevant stimuli, and is followed by presentation of target (T) or non-target (NT). In Rosenfeld et al. (2015), probes and irrelevants regularly alternated modality over trials, but Ts and NTs were always visual. In the present study, (in both its experiments, EXP 1 and EXP 2), probes and irrelevants alternated modalities on successive trials, as before. In present EXP 1, Ts and NTs were always auditory, but in EXP 2, they were simultaneously auditory and visual. Probe P300 data were different in each study: In Rosenfeld et al. (2015) and EXP 2 here, the bootstrap-based detection rates based on probe-minus-irrelevant differences, significantly differed favoring visual probe and irrelevant presentation modality. In EXP 1 here, detection rates were the same for the two modalities. In Rosenfeld et al. (2015) there was no main effect of probe modality, visual vs. auditory on probe-minus-irrelevant P300 difference. There were such effects here in EXP 1 (pvisual modality. Probe P300 latencies were shorter for visual than for auditory stimuli in Rosenfeld et al. (2015), a trend specifically reversed in the present pair of studies. RT was faster for visual stimuli in the present studies. The T and NT modality appears to interact with probe/irrelevant modality, and the best protocol for detecting concealed information is with the 2015 study protocol or that of EXP 2, using visual stimulus presentation. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Peripheral Neuropathy: Symptoms and Signs

    Science.gov (United States)

    ... Utah Research News Make a Difference Symptoms of Peripheral Neuropathy Print This Page Peripheral Neuropathy symptoms usually start ... more slowly over many years. The symptoms of peripheral neuropathy often include: A sensation of wearing an invisible “ ...

  6. Metacognitive monitoring and control in visual change detection: Implications for situation awareness and cognitive control

    Science.gov (United States)

    McAnally, Ken I.; Morris, Adam P.; Best, Christopher

    2017-01-01

    Metacognitive monitoring and control of situation awareness (SA) are important for a range of safety-critical roles (e.g., air traffic control, military command and control). We examined the factors affecting these processes using a visual change detection task that included representative tactical displays. SA was assessed by asking novice observers to detect changes to a tactical display. Metacognitive monitoring was assessed by asking observers to estimate the probability that they would correctly detect a change, either after study of the display and before the change (judgement of learning; JOL) or after the change and detection response (judgement of performance; JOP). In Experiment 1, observers failed to detect some changes to the display, indicating imperfect SA, but JOPs were reasonably well calibrated to objective performance. Experiment 2 examined JOLs and JOPs in two task contexts: with study-time limits imposed by the task or with self-pacing to meet specified performance targets. JOPs were well calibrated in both conditions as were JOLs for high performance targets. In summary, observers had limited SA, but good insight about their performance and learning for high performance targets and allocated study time appropriately. PMID:28915244

  7. Correlation between serum vitamin B12 level and peripheral neuropathy in atrophic gastritis

    Science.gov (United States)

    Yang, Guo-Tao; Zhao, Hong-Ying; Kong, Yu; Sun, Ning-Ning; Dong, Ai-Qin

    2018-01-01

    AIM To explore the correlation between serum vitamin B12 level and peripheral neuropathy in patients with chronic atrophic gastritis (CAG). METHODS A total of 593 patients diagnosed with chronic gastritis by gastroscopy and pathological examination from September 2013 to September 2016 were selected for this study. The age of these patients ranged within 18- to 75-years-old. Blood pressure, height and weight were measured in each patient, and the body mass index value was calculated. Furthermore, gastric acid, serum gastrin, serum vitamin and serum creatinine tests were performed, and peripheral nerve conduction velocity and Helicobacter pylori (H. pylori) were detected. In addition, the type of gastritis was determined by gastroscopy. The above factors were used as independent variables to analyze chronic gastritis with peripheral neuropathy and vitamin B12 deficiency risk factors, and to analyze the relationship between vitamin B12 levels and peripheral nerve conduction velocity. In addition, in the treatment of CAG on the basis of vitamin B12, patients with peripheral neuropathy were observed. RESULTS Age, H. pylori infection, CAG, vitamin B9 and vitamin B12 were risk factors for the occurrence of peripheral nerve degeneration. Furthermore, CAG and H. pylori infection were risk factors for chronic gastritis associated with vitamin B12 deficiency. Serum vitamin B12 level was positively correlated with sensory nerve conduction velocity in the tibial nerve (R = 0.463). After vitamin B12 supplementation, patients with peripheral neuropathy improved. CONCLUSION Serum vitamin B12 levels in patients with chronic gastritis significantly decreased, and the occurrence of peripheral neuropathy had a certain correlation. CAG and H. pylori infection are risk factors for vitamin B12 deficiency and peripheral neuropathy. When treating CAG, vitamin B12 supplementation can significantly reduce peripheral nervous system lesions. Therefore, the occurrence of peripheral neuropathy

  8. Correlation between serum vitamin B12 level and peripheral neuropathy in atrophic gastritis.

    Science.gov (United States)

    Yang, Guo-Tao; Zhao, Hong-Ying; Kong, Yu; Sun, Ning-Ning; Dong, Ai-Qin

    2018-03-28

    To explore the correlation between serum vitamin B12 level and peripheral neuropathy in patients with chronic atrophic gastritis (CAG). A total of 593 patients diagnosed with chronic gastritis by gastroscopy and pathological examination from September 2013 to September 2016 were selected for this study. The age of these patients ranged within 18- to 75-years-old. Blood pressure, height and weight were measured in each patient, and the body mass index value was calculated. Furthermore, gastric acid, serum gastrin, serum vitamin and serum creatinine tests were performed, and peripheral nerve conduction velocity and Helicobacter pylori ( H. pylori ) were detected. In addition, the type of gastritis was determined by gastroscopy. The above factors were used as independent variables to analyze chronic gastritis with peripheral neuropathy and vitamin B12 deficiency risk factors, and to analyze the relationship between vitamin B12 levels and peripheral nerve conduction velocity. In addition, in the treatment of CAG on the basis of vitamin B12, patients with peripheral neuropathy were observed. Age, H. pylori infection, CAG, vitamin B9 and vitamin B12 were risk factors for the occurrence of peripheral nerve degeneration. Furthermore, CAG and H. pylori infection were risk factors for chronic gastritis associated with vitamin B12 deficiency. Serum vitamin B12 level was positively correlated with sensory nerve conduction velocity in the tibial nerve ( R = 0.463). After vitamin B12 supplementation, patients with peripheral neuropathy improved. Serum vitamin B12 levels in patients with chronic gastritis significantly decreased, and the occurrence of peripheral neuropathy had a certain correlation. CAG and H. pylori infection are risk factors for vitamin B12 deficiency and peripheral neuropathy. When treating CAG, vitamin B12 supplementation can significantly reduce peripheral nervous system lesions. Therefore, the occurrence of peripheral neuropathy associated with vitamin B12

  9. Visual-Spatial Attention Aids the Maintenance of Object Representations in Visual Working Memory

    Science.gov (United States)

    Williams, Melonie; Pouget, Pierre; Boucher, Leanne; Woodman, Geoffrey F.

    2013-01-01

    Theories have proposed that the maintenance of object representations in visual working memory is aided by a spatial rehearsal mechanism. In this study, we used two different approaches to test the hypothesis that overt and covert visual-spatial attention mechanisms contribute to the maintenance of object representations in visual working memory. First, we tracked observers’ eye movements while remembering a variable number of objects during change-detection tasks. We observed that during the blank retention interval, participants spontaneously shifted gaze to the locations that the objects had occupied in the memory array. Next, we hypothesized that if attention mechanisms contribute to the maintenance of object representations, then drawing attention away from the object locations during the retention interval would impair object memory during these change-detection tasks. Supporting this prediction, we found that attending to the fixation point in anticipation of a brief probe stimulus during the retention interval reduced change-detection accuracy even on the trials in which no probe occurred. These findings support models of working memory in which visual-spatial selection mechanisms contribute to the maintenance of object representations. PMID:23371773

  10. Non-invasive peripheral nerve stimulation via focused ultrasound in vivo

    Science.gov (United States)

    Downs, Matthew E.; Lee, Stephen A.; Yang, Georgiana; Kim, Seaok; Wang, Qi; Konofagou, Elisa E.

    2018-02-01

    Focused ultrasound (FUS) has been employed on a wide range of clinical applications to safely and non-invasively achieve desired effects that have previously required invasive and lengthy procedures with conventional methods. Conventional electrical neuromodulation therapies that are applied to the peripheral nervous system (PNS) are invasive and/or non-specific. Recently, focused ultrasound has demonstrated the ability to modulate the central nervous system and ex vivo peripheral neurons. Here, for the first time, noninvasive stimulation of the sciatic nerve eliciting a physiological response in vivo is demonstrated with FUS. FUS was applied on the sciatic nerve in mice with simultaneous electromyography (EMG) on the tibialis anterior muscle. EMG signals were detected during or directly after ultrasound stimulation along with observable muscle contraction of the hind limb. Transecting the sciatic nerve downstream of FUS stimulation eliminated EMG activity during FUS stimulation. Peak-to-peak EMG response amplitudes and latency were found to be comparable to conventional electrical stimulation methods. Histology along with behavioral and thermal testing did not indicate damage to the nerve or surrounding regions. The findings presented herein demonstrate that FUS can serve as a targeted, safe and non-invasive alternative to conventional peripheral nervous system stimulation to treat peripheral neuropathic diseases in the clinic.

  11. Radiomic features for prostate cancer detection on MRI differ between the transition and peripheral zones: Preliminary findings from a multi-institutional study.

    Science.gov (United States)

    Ginsburg, Shoshana B; Algohary, Ahmad; Pahwa, Shivani; Gulani, Vikas; Ponsky, Lee; Aronen, Hannu J; Boström, Peter J; Böhm, Maret; Haynes, Anne-Maree; Brenner, Phillip; Delprado, Warick; Thompson, James; Pulbrock, Marley; Taimen, Pekka; Villani, Robert; Stricker, Phillip; Rastinehad, Ardeshir R; Jambor, Ivan; Madabhushi, Anant

    2017-07-01

    To evaluate in a multi-institutional study whether radiomic features useful for prostate cancer (PCa) detection from 3 Tesla (T) multi-parametric MRI (mpMRI) in the transition zone (TZ) differ from those in the peripheral zone (PZ). 3T mpMRI, including T2-weighted (T2w), apparent diffusion coefficient (ADC) maps, and dynamic contrast-enhanced MRI (DCE-MRI), were retrospectively obtained from 80 patients at three institutions. This study was approved by the institutional review board of each participating institution. First-order statistical, co-occurrence, and wavelet features were extracted from T2w MRI and ADC maps, and contrast kinetic features were extracted from DCE-MRI. Feature selection was performed to identify 10 features for PCa detection in the TZ and PZ, respectively. Two logistic regression classifiers used these features to detect PCa and were evaluated by area under the receiver-operating characteristic curve (AUC). Classifier performance was compared with a zone-ignorant classifier. Radiomic features that were identified as useful for PCa detection differed between TZ and PZ. When classification was performed on a per-voxel basis, a PZ-specific classifier detected PZ tumors on an independent test set with significantly higher accuracy (AUC = 0.61-0.71) than a zone-ignorant classifier trained to detect cancer throughout the entire prostate (P  0.14) were obtained for all institutions. A zone-aware classifier significantly improves the accuracy of cancer detection in the PZ. 3 Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;46:184-193. © 2016 International Society for Magnetic Resonance in Medicine.

  12. Novelty enhances visual salience independently of reward in the parietal lobe.

    Science.gov (United States)

    Foley, Nicholas C; Jangraw, David C; Peck, Christopher; Gottlieb, Jacqueline

    2014-06-04

    Novelty modulates sensory and reward processes, but it remains unknown how these effects interact, i.e., how the visual effects of novelty are related to its motivational effects. A widespread hypothesis, based on findings that novelty activates reward-related structures, is that all the effects of novelty are explained in terms of reward. According to this idea, a novel stimulus is by default assigned high reward value and hence high salience, but this salience rapidly decreases if the stimulus signals a negative outcome. Here we show that, contrary to this idea, novelty affects visual salience in the monkey lateral intraparietal area (LIP) in ways that are independent of expected reward. Monkeys viewed peripheral visual cues that were novel or familiar (received few or many exposures) and predicted whether the trial will have a positive or a negative outcome--i.e., end in a reward or a lack of reward. We used a saccade-based assay to detect whether the cues automatically attracted or repelled attention from their visual field location. We show that salience--measured in saccades and LIP responses--was enhanced by both novelty and positive reward associations, but these factors were dissociable and habituated on different timescales. The monkeys rapidly recognized that a novel stimulus signaled a negative outcome (and withheld anticipatory licking within the first few presentations), but the salience of that stimulus remained high for multiple subsequent presentations. Therefore, novelty can provide an intrinsic bonus for attention that extends beyond the first presentation and is independent of physical rewards. Copyright © 2014 the authors 0270-6474/14/347947-11$15.00/0.

  13. Easy and Rapid Detection of Mumps Virus by Live Fluorescent Visualization of Virus-Infected Cells.

    Directory of Open Access Journals (Sweden)

    Tadanobu Takahashi

    Full Text Available Mumps viruses show diverse cytopathic effects (CPEs of infected cells and viral plaque formation (no CPE or no plaque formation in some cases depending on the viral strain, highlighting the difficulty in mumps laboratory studies. In our previous study, a new sialidase substrate, 2-(benzothiazol-2-yl-4-bromophenyl 5-acetamido-3,5-dideoxy-α-D-glycero-D-galacto-2-nonulopyranosidonic acid (BTP3-Neu5Ac, was developed for visualization of sialidase activity. BTP3-Neu5Ac can easily and rapidly perform histochemical fluorescent visualization of influenza viruses and virus-infected cells without an antiviral antibody and cell fixation. In the present study, the potential utility of BTP3-Neu5Ac for rapid detection of mumps virus was demonstrated. BTP3-Neu5Ac could visualize dot-blotted mumps virus, virus-infected cells, and plaques (plaques should be called focuses due to staining of infected cells in this study, even if a CPE was not observed. Furthermore, virus cultivation was possible by direct pick-up from a fluorescent focus. In conventional methods, visible appearance of the CPE and focuses often requires more than 6 days after infection, but the new method with BTP3-Neu5Ac clearly visualized infected cells after 2 days and focuses after 4 days. The BTP3-Neu5Ac assay is a precise, easy, and rapid assay for confirmation and titration of mumps virus.

  14. [Age-related changes of sensory peripheral nerve system in healthy subjects.

    Science.gov (United States)

    Voitenkov, V B; Ekusheva, E V; Komancev, V N; Skripchenko, N V; Grigoryev, S G; Klimkin, A V; Aksenova, A I

    2017-01-01

    Our aim was to present and evaluate age-related changes of peripheral nerves of limbs on a huge population of healthy subjects of different ages. In 2009-2016 subjects aged from 1months to 90 years were studied by nerve conduction velocity studies (NCV). Data of those confirmed healthy was included in our study. In total there were 372 healthy subjects. NCV for nn. Medianus et Ulnaris was registered, with NCV and amplitude of compound sensory action potential (CSAP) being analyzed. There were significant differences on both these parameters between different age groups. Since the childhood the improvement of conduction (which was reflected in rising of CSAP amplitudes and NCV quickening) was registered; from 40-50 years steady decline of both these parameters were observed in both nerves. Conduction studies of peripheral nerves may be implemented in gerontology for early detection of neurophysiology patterns reflecting physiological aging. Also our results may be implemented for accelerated aging detection.

  15. Donating Peripheral Blood Stem Cells

    Science.gov (United States)

    ... Print this page My Cart Donating peripheral blood stem cells Peripheral blood stem cell (PBSC) donation is a nonsurgical procedure to collect ... Donating bone marrow Donor experiences videos Peripheral blood stem cell (PBSC) donation is one of two methods of ...

  16. Individual differences in attention strategies during detection, fine discrimination, and coarse discrimination

    Science.gov (United States)

    Hecker, Elizabeth A.; Serences, John T.; Srinivasan, Ramesh

    2013-01-01

    Interacting with the environment requires the ability to flexibly direct attention to relevant features. We examined the degree to which individuals attend to visual features within and across Detection, Fine Discrimination, and Coarse Discrimination tasks. Electroencephalographic (EEG) responses were measured to an unattended peripheral flickering (4 or 6 Hz) grating while individuals (n = 33) attended to orientations that were offset by 0°, 10°, 20°, 30°, 40°, and 90° from the orientation of the unattended flicker. These unattended responses may be sensitive to attentional gain at the attended spatial location, since attention to features enhances early visual responses throughout the visual field. We found no significant differences in tuning curves across the three tasks in part due to individual differences in strategies. We sought to characterize individual attention strategies using hierarchical Bayesian modeling, which grouped individuals into families of curves that reflect attention to the physical target orientation (“on-channel”) or away from the target orientation (“off-channel”) or a uniform distribution of attention. The different curves were related to behavioral performance; individuals with “on-channel” curves had lower thresholds than individuals with uniform curves. Individuals with “off-channel” curves during Fine Discrimination additionally had lower thresholds than those assigned to uniform curves, highlighting the perceptual benefits of attending away from the physical target orientation during fine discriminations. Finally, we showed that a subset of individuals with optimal curves (“on-channel”) during Detection also demonstrated optimal curves (“off-channel”) during Fine Discrimination, indicating that a subset of individuals can modulate tuning optimally for detection and discrimination. PMID:23678013

  17. Detecting effects of donepezil on visual selective attention using signal detection parameters in Alzheimer's disease.

    Science.gov (United States)

    Foldi, Nancy S; White, Richard E C; Schaefer, Lynn A

    2005-05-01

    Attentional function is impaired in Alzheimer's disease (AD). Moreover, attention is mediated by acetylcholine. But, despite the widespread use of acetylcholinesterase inhibitors (AChE-I) to augment available acetylcholine in AD, measures of attentional function have not been used to assess the drug response. We hypothesized that as cholinergic augmentation impacts directly on the attentional system, higher-order measures of visual selective attention would be sensitive to effects of treatment using an AChE-I (donepezil hydrochloride). We also sought to determine whether these attentional measures were more sensitive to treatment than other measures of cognitive function. Seventeen patients with AD (8 untreated, 9 treated with donepezil) were contrasted on performance of a selective cancellation task. Two signal detection parameters were used as outcome measures: decision strategy (beta, beta) and discriminability (d-prime, d'). Standard screening and cognitive domain measures of vigilance, language, memory, and executive function were also contrasted. Treated patients judged stimuli more conservatively (p = 0.29) by correctly endorsing targets and rejecting false alarms. They also discriminated targets from distractors more easily (p = 0.58). The screening and neuropsychological measures failed to differentiate the groups. Higher-order attentional measures captured the effects of donepezil treatment in small groups of patients with AD. The results suggest that cholinergic availability may directly affect the attentional system, and that these selective attention measures are sensitive markers to detect treatment response. Copyright 2005 John Wiley & Sons, Ltd.

  18. Cholinergic enhancement reduces orientation-specific surround suppression but not visual crowding

    Directory of Open Access Journals (Sweden)

    Anna A. Kosovicheva

    2012-09-01

    Full Text Available Acetylcholine (ACh reduces the spatial spread of excitatory fMRI responses in early visual cortex and the receptive field sizes of V1 neurons. We investigated the perceptual consequences of these physiological effects of ACh with surround suppression and crowding, two tasks that involve spatial interactions between visual field locations. Surround suppression refers to the reduction in perceived stimulus contrast by a high-contrast surround stimulus. For grating stimuli, surround suppression is selective for the relative orientations of the center and surround, suggesting that it results from inhibitory interactions in early visual cortex. Crowding refers to impaired identification of a peripheral stimulus in the presence of flankers and is thought to result from excessive integration of visual features. We increased synaptic ACh levels by administering the cholinesterase inhibitor donepezil to healthy human subjects in a placebo-controlled, double-blind design. In Exp. 1, we measured surround suppression of a central grating using a contrast discrimination task with three conditions: 1 surround grating with the same orientation as the center (parallel, 2 surround orthogonal to the center, or 3 no surround. Contrast discrimination thresholds were higher in the parallel than in the orthogonal condition, demonstrating orientation-specific surround suppression (OSSS. Cholinergic enhancement reduced thresholds only in the parallel condition, thereby reducing OSSS. In Exp. 2, subjects performed a crowding task in which they reported the identity of a peripheral letter flanked by letters on either side. We measured the critical spacing between the target and flanking letters that allowed reliable identification. Cholinergic enhancement had no effect on critical spacing. Our findings suggest that ACh reduces spatial interactions in tasks involving segmentation of visual field locations but that these effects may be limited to early visual cortical

  19. Foundations of computer vision computational geometry, visual image structures and object shape detection

    CERN Document Server

    Peters, James F

    2017-01-01

    This book introduces the fundamentals of computer vision (CV), with a focus on extracting useful information from digital images and videos. Including a wealth of methods used in detecting and classifying image objects and their shapes, it is the first book to apply a trio of tools (computational geometry, topology and algorithms) in solving CV problems, shape tracking in image object recognition and detecting the repetition of shapes in single images and video frames. Computational geometry provides a visualization of topological structures such as neighborhoods of points embedded in images, while image topology supplies us with structures useful in the analysis and classification of image regions. Algorithms provide a practical, step-by-step means of viewing image structures. The implementations of CV methods in Matlab and Mathematica, classification of chapter problems with the symbols (easily solved) and (challenging) and its extensive glossary of key words, examples and connections with the fabric of C...

  20. Application of PCR-based DNA sequencing technique for the detection of Leptospira in peripheral blood of septicemia patients

    Directory of Open Access Journals (Sweden)

    Ram, S.

    2012-01-01

    Full Text Available Aim: Isolation, dark field detection and microscopic agglutination test (MAT are considered ―gold standard‖ tests for diagnosis of Leptospirosis. Several PCR assays are reported but very few have been evaluated for detection of Leptospirosis. Therefore, this study was undertaken. This study aims to design and standardize polymerase chain reaction (PCR - based DNA sequencing technique for the detection of pathogenic Leptospira from peripheral blood of patients clinically diagnosed with septicemia. Methodology and Results: Two hundred and seven (207 blood samples from patients were diagnosed with septicemia which includes 100 bacterial (other than Leptospira culture positive and 107 bacterial culture negative samples were studied. Primers for Nested PCR targeting LipL32 gene of Leptospira interrogans were designed and the specificity of primers was tested against serum samples positive/negative by either MAT or dark field microscopy. PCR amplified products were further confirmed by DNA sequencing. The standardized nPCR was sensitive and specific to Leptospira interrogans. Twenty-one (21% out of 100 culture positive blood samples, three (2.8% out of 107 culture negative samples showed nPCR positivity and were confirmed as Leptospira interrogans by DNA sequencing (p<0.001. A sensitive nPCR specific to Leptospira interrogans was developed. Conclusion, significance and impact of study: The p value (<0.001 signifies that Leptospira is commonly associated with other bacteria circulating in blood indicating that a decreased immune status is created primarily by a bacterium with enhanced possibility of development of Leptospiral infection probably be of an endogenous origin.

  1. Relationship between peripheral leptin receptor and leptin in obese subjects

    International Nuclear Information System (INIS)

    Sun Junjiang; Du Tongxin; Wang Zizheng; Wang Shukui; Huang Min

    2002-01-01

    Objective: To investigate the relationship between leptin resistance and leptin receptor in obese subjects. Methods: Forty-four individuals undergoing surgery, exclusive of diabetic mellitus, chronic inflammatory and malignant diseases, were divided into 3 groups according to the body mass index (BMI), normal controls (n=15), weight excess (n=14), and obesity group (n=15). Fasting serum leptin were detected via ELISA kits, leptin receptor (Bmax) in peripheral adipose tissues was detected by radioligand assay. Results: Serum leptin levels were higher significantly in weight excess and obesity cases groups (10.3±4.45 and 13.2±3.26 vs 5.51±3.23 μg/L, both P<0.05, respectively) compared with normal control group, suggesting the existence of leptin resistance, while the leptin receptor of the weight excess and obese groups decreased significantly than that of normal control group (36.9 ± 5.89 and 24.3 ± 3.95 vs 76.5 ± 35.3 fmol/mg protein, both P<0.01, respectively), there was no statistical differences for Kd value among three groups. Also, there was a negative correlation between BMI and leptin receptor (r=-0.613, P<0.05), and no significant correlation was found between serum leptin and peripheral leptin receptor. Conclusion: The result suggested that there was expression of leptin receptor in peripheral adipose tissues and low level of leptin receptor expression may contribute to the development of leptin resistance and obesity

  2. Central and Peripheral Vision Loss Differentially Affects Contextual Cueing in Visual Search

    Science.gov (United States)

    Geringswald, Franziska; Pollmann, Stefan

    2015-01-01

    Visual search for targets in repeated displays is more efficient than search for the same targets in random distractor layouts. Previous work has shown that this contextual cueing is severely impaired under central vision loss. Here, we investigated whether central vision loss, simulated with gaze-contingent displays, prevents the incidental…

  3. In-Line Filtration Reduces Postoperative Venous Peripheral Phlebitis Associated With Cannulation: A Randomized Clinical Trial.

    Science.gov (United States)

    Villa, Gianluca; Chelazzi, Cosimo; Giua, Rosa; Tofani, Lorenzo; Zagli, Giovanni; Boninsegni, Paolo; Pinelli, Fulvio; De Gaudio, A Raffaele; Romagnoli, Stefano

    2018-04-23

    Peripheral venous cannulation is an everyday practice of care for patients undergoing anesthesia and surgery. Particles infused with intravenous fluids (eg, plastic/glass/drugs particulate) contribute to the pathogenesis of peripheral phlebitis. The aim of this study is to demonstrate the efficacy of in-line filtration in reducing the incidence of postoperative phlebitis associated with peripheral short-term vascular access. In this controlled trial, 268 surgical patients were randomly assigned to in-line filtration and standard care (NCT03193827). The incidence of phlebitis (defined as visual infusion phlebitis [VIP] score, ≥2) within 48 hours was compared between the 2 groups, as well as the onset and severity of phlebitis and the reasons for removal of the cannula. The lifespan of venous cannulae was compared for the in-line filter and no-filter groups through a Kaplan-Meier curve. The incidence of phlebitis within 48 hours postoperatively was 2.2% and 26.9% (difference, 25% [95% confidence interval {CI}, 12%-36%]; odds ratio, 0.05 [0.01-0.15]), respectively, for the in-line filter and no-filter groups (P phlebitis (hazard ratio, 0.05 [95% CI, 0.014-0.15]; P phlebitis and prolongs cannula lifespan during peripheral venous cannulation in surgical patients.

  4. Potential Peripheral Biomarkers for the Diagnosis of Alzheimer's Disease

    Directory of Open Access Journals (Sweden)

    Seema Patel

    2011-01-01

    Full Text Available Advances in the discovery of a peripheral biomarker for the diagnosis of Alzheimer's would provide a way to better detect the onset of this debilitating disease in a manner that is both noninvasive and universally available. This paper examines the current approaches that are being used to discover potential biomarker candidates available in the periphery. The search for a peripheral biomarker that could be utilized diagnostically has resulted in an extensive amount of studies that employ several biological approaches, including the assessment of tissues, genomics, proteomics, epigenetics, and metabolomics. Although a definitive biomarker has yet to be confirmed, advances in the understanding of the mechanisms of the disease and major susceptibility factors have been uncovered and reveal promising possibilities for the future discovery of a useful biomarker.

  5. [Colorimetric card use for early detection visual biliary atresia].

    Science.gov (United States)

    Reyes-Cerecedo, Alicia; Flores-Calderón, Judith; Villasis-Keever, Miguel Á; Chávez-Barrera, José A; Delgado-González, Elba E

    2018-01-01

    Bile duct atresia (BVA) is a condition that causes obstruction to biliary flow, not corrected surgically, causes cirrhosis and death before 2 years of age. In Mexico from 2013 the visual colorimetric card (VVC) was incorporated for the timely detection of BVA to the National Health Card (NHC). The aim of this study was to evaluate the impact of VCT for the detection of BVA before and after the use of NHC incorporation. Ambispective, analytical observational study. We included patients with AVB treated in two pediatric hospitals of third level care. We compared the age of reference, diagnosis and surgery before and after incorporation of the TCV. In addition, a questionnaire was made to the parents to know their perception about the TCV. In 59 children, there were no differences in age at diagnosis (75 vs 70 days) and age at surgery (84 vs 90 days) between the pre and post-implementation period of the VVC. The questionnaire showed that 10 (30%) of the parents received information about the use of the VVC and 13 (38%) identified the abnormal evacuations. This study did not show changes in time for the timely detection of BVA by using VVC. Therefore, it is necessary to reinforce the program in the three levels of care in our country. La atresia de vías biliares (AVB) es una condición que provoca obstrucción al flujo biliar, y de no corregirse quirúrgicamente, provoca cirrosis y la muerte antes de los 2 años de edad. En México, a partir del año 2013 se incorporó la tarjeta colorimétrica visual (TCV) para la detección oportuna de la AVB a la Cartilla Nacional de Salud (CNS). El objetivo de este estudio fue evaluar el impacto de la TCV para la detección de AVB antes y después de su incorporación a la CNS. Estudio ambispectivo, observacional y analítico. Se incluyeron pacientes con AVB atendidos en dos hospitales pediátricos de tercer nivel de atención. Se compararon la edad de referencia, el diagnóstico y la cirugía antes y después de la incorporaci

  6. Stability of medicines after repackaging into multicompartment compliance aids: eight criteria for detection of visual alteration

    OpenAIRE

    Albert, Valerie; Lanz, Michael; Imanidis, Georgios; Hersberger, Kurt E.; Arnet, Isabelle

    2017-01-01

    Introduction Multicompartment compliance aids (MCA) are widely used by patients. They support the management of medication and reduce unintentional nonadherence. MCA are filled with medicines unpacked from their original packaging. Swiss pharmacists currently provide MCA for 1–2 weeks, although little and controversial information exists on the stability of repackaged medicines. Objective We aimed to validate the usefulness of a simple screening method capable of detecting visual stability pr...

  7. A novel approach to 32-channel peripheral nervous system myelin imaging in vivo, with single axon resolution.

    Science.gov (United States)

    Grochmal, Joey; Teo, Wulin; Gambhir, Hardeep; Kumar, Ranjan; Stratton, Jo Anne; Dhaliwal, Raveena; Brideau, Craig; Biernaskie, Jeff; Stys, Peter K; Midha, Rajiv

    2018-01-19

    OBJECTIVE Intravital spectral imaging of the large, deeply situated nerves in the rat peripheral nervous system (PNS) has not been well described. Here, the authors have developed a highly stable platform for performing imaging of the tibial nerve in live rodents, thus allowing the capture of high-resolution, high-magnification spectral images requiring long acquisition times. By further exploiting the qualities of the topically applied myelin dye Nile red, this technique is capable of visualizing the detailed microenvironment of peripheral nerve demyelination injury and recovery, while allowing us to obtain images of exogenous Schwann cell myelination in a living animal. METHODS The authors caused doxorubicin-induced focal demyelination in the tibial nerves of 25 Thy-1 GFP rats, of which 2 subsets (n = 10 each) received either BFP-labeled SKP-SCs or SCs to the zone of injury. Prior to acquiring images of myelin recovery in these nerves, a tibial nerve window was constructed using a silicone hemitube, a fast drying silicone polymer, and a small coverslip. This construct was then affixed to a 3D-printed nerve stage, which in turn was affixed to an external fixation/microscope stage device. Myelin visualization was facilitated by the topical application of Nile red. RESULTS The authors reliably demonstrated intravital peripheral nerve myelin imaging with micron-level resolution and magnification, and minimal movement artifact. The detailed microenvironment of nerve remyelination can be vividly observed, while exogenously applied Schwann cells and skin-derived precursor Schwann cells can be seen myelinating axons. CONCLUSIONS Topically applied Nile red enables intravital study of myelin in the living rat PNS. Furthermore, the use of a tibial nerve window facilitates stable intravital peripheral nerve imaging, making possible high-definition spectral imaging with long acquisition times.

  8. New Ways to Detect Pediatric Sickle Cell Retinopathy: A Comprehensive Review.

    Science.gov (United States)

    Pahl, Daniel A; Green, Nancy S; Bhatia, Monica; Chen, Royce W S

    2017-11-01

    Sickle retinopathy reflects disease-related vascular injury of the eye, which can potentially result in visual loss from vitreous hemorrhage or retinal detachment. Here we review sickle retinopathy among children with sickle cell disease, describe the epidemiology, pediatric risk factors, pathophysiology, ocular findings, and treatment. Newer, more sensitive ophthalmological imaging modalities are available for retinal imaging, including ultra-widefield fluorescein angiography, spectral-domain optical coherence tomography, and optical coherence tomography angiography. Optical coherence tomography angiography provides a noninvasive view of retinal vascular layers that could previously not be imaged and can be quantified for comparative or prospective analyses. Ultra-widefield fluorescein angiography provides a more comprehensive view of the peripheral retina than traditional imaging techniques. Screening for retinopathy by standard fundoscopic imaging modalities detects a prevalence of approximately 10%. In contrast, these more sensitive methods allow for more sensitive examination that includes the retina perimeter where sickle retinopathy is often first detectable. Use of these new imaging modalities may detect a higher prevalence of early sickle pathology among children than has previously been reported. Earlier detection may help in better understanding the pathogenesis of sickle retinopathy and guide future screening and treatment paradigms.

  9. [Usefulness of the ankle-arm index for detection of peripheral arterial disease in a working population of Junta de Andalucía at Málaga].

    Science.gov (United States)

    Alonso, Inmaculada; Valdivielso, Pedro; Josefa Zamudio, María; Sánchez Chaparro, Miguel Angel; Pérez, Francisca; Ramos, Heliodoro; González Santos, Pedro

    2009-01-17

    Detection of asymptomatic peripheral arterial disease increases the risk of vascular morbibity and mortality. We aimed to estimate the prevalence of clinical and subclinical peripheral arterial disease using the ankle-arm index (AAI) as diagnostic tool in a working population. We included 450 workers, older than 50 years old, attending voluntary regular health check-up at Centro de Prevención de Riesgos Laborales de la Junta de Andalucía in Málaga (Spain). We recorded clinical and anthopometrical data. Blood samples were taken after an overnight fast. Vascular risk was calculated using Framinghan and SCORE scales. Every participant was asked for symptoms of intermittent claudicatio and AAI was measured. AAI was considered normal within 0.9-1.3 values. Most of our workers were at low- or moderate vascular risk. Only 48 (10.6%) of individuals had an abnormal AAI: 9 (2%) showed an AAI1.3. An AAI or = 5%, and in 11% of those having a Framinghan risk > or = 20%. Intermittent claudication was present in 4 out of 9 (44%) of those having an AAI<0.9 and in 7 out of 402 (1.7%) with a normal AAI. Systematic screening of peripheral arterial disease using the AAI is not recommended in active working population over 50 years-old of age. Thus, AAI measurement is indicated only for those individuals suffering from intermitent claudicatio and those who are at moderate- or high vascular risk.

  10. Detection of HIV-RNA-positive monocytes in peripheral blood of HIV-positive patients by simultaneous flow cytometric analysis of intracellular HIV RNA and cellular immunophenotype.

    Science.gov (United States)

    Patterson, B K; Mosiman, V L; Cantarero, L; Furtado, M; Bhattacharya, M; Goolsby, C

    1998-04-01

    Determinations of plasma HIV viral RNA copy numbers help to define the kinetics of HIV-1 infection in vivo and to monitor antiretroviral therapy. However, questions remain regarding the identity of various infected cell types contributing to this free virus pool and to the in vivo lifecycle of HIV during disease progression. Characterization of a novel fluorescence in situ hybridization (FISH) assay employing a pool of labeled oligonucleotide probes directed against HIV RNA was done followed by coupling of the FISH assay with simultaneous surface immunophenotyping to address these questions. In vitro characterizations of this assay using tumor necrosis factor-alpha stimulated and unstimulated ACH-2 cells demonstrated the ability to detect < 5% HIV RNA positive cells with a sensitivity of < 30 RNA copies per cell. Peripheral blood mononuclear cells from 39 HIV-seropositive patients on no, single, combination, or triple drug therapy and 8 HIV-seronegative patients were examined. The majority of HIV-positive patients (24/39) harbored monocytes positive for HIV RNA and a significantly higher fraction of patients with high plasma viral load carried positive monocytes (13/16) than did patients in the low plasma viral load group (11/23). These results demonstrate the effectiveness of a novel FISH assay for identifying and monitoring HIV-infected cell populations in the peripheral blood of HIV-positive patients. In addition, monocytes are a major source of cellular HIV virus in the peripheral blood of HIV patients, even with progression of disease.

  11. Autoradiographic visualization of A 1-adenosine receptors in brain and peripheral tissues of rat and guinea pig using 125I-HPIA

    International Nuclear Information System (INIS)

    Weber, R.G.; Lohse, M.J.; Jones, C.R.; Palacios, J.M.

    1988-01-01

    A 1 -adenosine receptors were identified in sections of rat brain and guinea pig kidney with the radioiodinated agonist 1 25I-N 6 -p-hydroxyphenylisopropyladenosine ( 1 25I-HPIA) using in vitro autoradiography. The affinities of adenosine receptor ligands in competing with 1 25I-HPIA binding to tissue sections were in good agreement with those found in membranes and indicate that the binding site represents an A 1 pattern of [ 3 H]N 6 -cyclohexyladenosine ([ 3 H]CHA) binding sites determined previously, with highest densities in the hippocampus and dentate gyrus, the cerebellar cortex, some thalamic nuclei and certain layers of the cerebral cortex. In the guinea pig kidney 1 25I-HPIA labelled longitudinal structures in the medulla. This study demonstrates that 1 25I-HPIA allows the autoradiographic detection of A-1 adenosine receptors in the brain and peripheral organs and has the advantage of short exposure times (author)

  12. Visual long-term memory and change blindness: Different effects of pre- and post-change information on one-shot change detection using meaningless geometric objects.

    Science.gov (United States)

    Nishiyama, Megumi; Kawaguchi, Jun

    2014-11-01

    To clarify the relationship between visual long-term memory (VLTM) and online visual processing, we investigated whether and how VLTM involuntarily affects the performance of a one-shot change detection task using images consisting of six meaningless geometric objects. In the study phase, participants observed pre-change (Experiment 1), post-change (Experiment 2), or both pre- and post-change (Experiment 3) images appearing in the subsequent change detection phase. In the change detection phase, one object always changed between pre- and post-change images and participants reported which object was changed. Results showed that VLTM of pre-change images enhanced the performance of change detection, while that of post-change images decreased accuracy. Prior exposure to both pre- and post-change images did not influence performance. These results indicate that pre-change information plays an important role in change detection, and that information in VLTM related to the current task does not always have a positive effect on performance. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. The Capabilities and Limitation of Remote Visual Methods to Detect Service-Induced Cracks in Reactor Components

    International Nuclear Information System (INIS)

    Cumblidge, Stephen E.; Doctor, Steven R.; Anderson, Michael T.

    2006-01-01

    Since 1977, the U.S. Nuclear Regulatory Commission (NRC) Office of Nuclear Regulatory Research has funded a multiyear program at the Pacific Northwest National Laboratory (PNNL) to evaluate the reliability and accuracy of nondestructive evaluation (NDE) techniques employed for inservice inspection (ISI). Recently, the U.S. nuclear industry proposed replacing current volumetric and/or surface examinations of certain components in commercial nuclear power plants, as required by ASME Boiler and Pressure Vessel Code Section XI, with a simpler visual testing (VT) method. The advantages of VT are that these tests generally involve much less radiation exposure and examination times than do volumetric examinations such as ultrasonic testing (UT). However, for industry to justify supplementing volumetric methods with VT, and analysis of pertinent issues is needed to support the reliability of VT in determining the structural integrity of reactor components. As piping and pressure vessel components in a nuclear power station are generally underwater and in high radiation field, they need to be examined by VT from a distance with radiation-hardened video systems. Remote visual testing has been used by nuclear utilities to find cracks in pressure vessel cladding in pressurized water reactors, for shrouds in boiling water reactors, and to investigate leaks in piping and reactor components. These visual tests are performed using a wide variety of procedures and equipment. The techniques for remote visual testing use submersible closed-circuit video cameras to examine reactor components and welds. PNNL has conducted a parametric study that examines the important variables that affect the effectiveness of a remote visual test. Tested variables include lighting techniques, camera resolution, camera movement, and magnification. PNNL has also conducted a laboratory test using a commercial visual testing camera system to experimentally determine the ability of the camera system to

  14. Influence of age, spatial memory, and ocular fixation on localization of auditory, visual, and bimodal targets by human subjects.

    Science.gov (United States)

    Dobreva, Marina S; O'Neill, William E; Paige, Gary D

    2012-12-01

    A common complaint of the elderly is difficulty identifying and localizing auditory and visual sources, particularly in competing background noise. Spatial errors in the elderly may pose challenges and even threats to self and others during everyday activities, such as localizing sounds in a crowded room or driving in traffic. In this study, we investigated the influence of aging, spatial memory, and ocular fixation on the localization of auditory, visual, and combined auditory-visual (bimodal) targets. Head-restrained young and elderly subjects localized targets in a dark, echo-attenuated room using a manual laser pointer. Localization accuracy and precision (repeatability) were quantified for both ongoing and transient (remembered) targets at response delays up to 10 s. Because eye movements bias auditory spatial perception, localization was assessed under target fixation (eyes free, pointer guided by foveal vision) and central fixation (eyes fixed straight ahead, pointer guided by peripheral vision) conditions. Spatial localization across the frontal field in young adults demonstrated (1) horizontal overshoot and vertical undershoot for ongoing auditory targets under target fixation conditions, but near-ideal horizontal localization with central fixation; (2) accurate and precise localization of ongoing visual targets guided by foveal vision under target fixation that degraded when guided by peripheral vision during central fixation; (3) overestimation in horizontal central space (±10°) of remembered auditory, visual, and bimodal targets with increasing response delay. In comparison with young adults, elderly subjects showed (1) worse precision in most paradigms, especially when localizing with peripheral vision under central fixation; (2) greatly impaired vertical localization of auditory and bimodal targets; (3) increased horizontal overshoot in the central field for remembered visual and bimodal targets across response delays; (4) greater vulnerability to

  15. Adipose-Derived Stem Cells Promote Peripheral Nerve Regeneration In Vivo without Differentiation into Schwann-Like Lineage.

    Science.gov (United States)

    Sowa, Yoshihiro; Kishida, Tsunao; Imura, Tetsuya; Numajiri, Toshiaki; Nishino, Kenichi; Tabata, Yasuhiko; Mazda, Osam

    2016-02-01

    During recent decades, multipotent stem cells were found to reside in the adipose tissue, and these adipose-derived stem cells were shown to play beneficial roles, like those of Schwann cells, in peripheral nerve regeneration. However, it has not been well established whether adipose-derived stem cells offer beneficial effects to peripheral nerve injuries in vivo as Schwann cells do. Furthermore, the in situ survival and differentiation of adipose-derived stem cells after transplantation at the injured peripheral nerve tissue remain to be fully elucidated. Adipose-derived stem cells and Schwann cells were transplanted with gelatin hydrogel tubes at the artificially blunted sciatic nerve lesion in mice. Neuroregenerative abilities of them were comparably estimated. Cre-loxP-mediated fate tracking was performed to visualize survival in vivo of transplanted adipose-derived stem cells and to investigate whether they differentiated into Schwann linage cells at the peripheral nerve injury site. The transplantation of adipose-derived stem cells promoted regeneration of axons, formation of myelin, and restoration of denervation muscle atrophy to levels comparable to those achieved by Schwann cell transplantation. The adipose-derived stem cells survived for at least 4 weeks after transplantation without differentiating into Schwann cells. Transplanted adipose-derived stem cells did not differentiate into Schwann cells but promoted peripheral nerve regeneration at the injured site. The neuroregenerative ability was comparable to that of Schwann cells. Adipose-derived stem cells at an undifferentiated stage may be used as an alternative cell source for autologous cell therapy for patients with peripheral nerve injury.

  16. Peripheral dentinogenic ghost cell tumor

    Directory of Open Access Journals (Sweden)

    Sushant S Kamat

    2013-01-01

    Full Text Available Dentinogenic ghost cell tumors (DGCT are uncommon lesions mainly with rare peripheral types. This report presents a case of peripheral DGCT on the left side of the mandibular alveolar ridge of a heavy smoker, a 68-year-old man, with main presenting feature as a mild pain. Submandibular lymphadenopathy and radiological "saucerization" were evident. Differential diagnosis included fibroma, neurofibroma, peripheral ameloblastoma, peripheral odontogenic fibroma, and peripheral giant cell granuloma. Histologically, ameloblastoma-like epithelial elements were seen in association with grouped ghost cells. Proliferating polyhedral cells and stellate reticulum-like cells with various densities were spread over a wide range of the field. The lesion was curetted and after 2 years of follow up, it did not recur.

  17. Vorrichtung zur visuellen Darstellung graphischer Detailinformationen

    OpenAIRE

    Eck, R.; Geisler, J.; Rehfeld, N.

    2006-01-01

    DE1004046151 A UPAB: 20060526 NOVELTY - The device has a peripheral display, and a graphic surface area, where graphic information is visually represented on the area. Another surface area provides information with higher optical resolution degree than the former area. A detection unit detects a relative position of the latter area relative to the former area. An imaging system (BS) visually provides the information based on the detected relative position of latter area. USE - Used for visual...

  18. Simultaneous detection of P300 and steady-state visually evoked potentials for hybrid brain-computer interface.

    Science.gov (United States)

    Combaz, Adrien; Van Hulle, Marc M

    2015-01-01

    We study the feasibility of a hybrid Brain-Computer Interface (BCI) combining simultaneous visual oddball and Steady-State Visually Evoked Potential (SSVEP) paradigms, where both types of stimuli are superimposed on a computer screen. Potentially, such a combination could result in a system being able to operate faster than a purely P300-based BCI and encode more targets than a purely SSVEP-based BCI. We analyse the interactions between the brain responses of the two paradigms, and assess the possibility to detect simultaneously the brain activity evoked by both paradigms, in a series of 3 experiments where EEG data are analysed offline. Despite differences in the shape of the P300 response between pure oddball and hybrid condition, we observe that the classification accuracy of this P300 response is not affected by the SSVEP stimulation. We do not observe either any effect of the oddball stimulation on the power of the SSVEP response in the frequency of stimulation. Finally results from the last experiment show the possibility of detecting both types of brain responses simultaneously and suggest not only the feasibility of such hybrid BCI but also a gain over pure oddball- and pure SSVEP-based BCIs in terms of communication rate.

  19. Detection of Felis catus gammaherpesvirus 1 (FcaGHV1) in peripheral blood B- and T-lymphocytes in asymptomatic, naturally-infected domestic cats

    Energy Technology Data Exchange (ETDEWEB)

    McLuckie, Alicia J.; Barrs, Vanessa R. [Faculty of Veterinary Science and Marie Bashir Institute for Infectious Diseases and Biosecurity, School of Life and Environmental Sciences, The University of Sydney, NSW 2006 (Australia); Smith, Adrian L. [Advanced Cytometry Facility, University of Sydney/Centenary Institute, NSW 2006 (Australia); Beatty, Julia A., E-mail: julia.beatty@sydney.edu.au [Faculty of Veterinary Science and Marie Bashir Institute for Infectious Diseases and Biosecurity, School of Life and Environmental Sciences, The University of Sydney, NSW 2006 (Australia)

    2016-10-15

    The domestic cat is natural host to both feline immunodeficiency virus and Felis catus gammaherpesvirus 1 (FcaGHV1). Comparative data suggest that these agents might act as synergistic copathogens in feline AIDS-related lymphoma. To identify leucocyte subsets harbouring gammaherpesvirus DNA, whole blood from 5 healthy, FcaGHV1-infected cats was labelled with monoclonal antibodies to feline CD21, CD4, CD8 and CD14 for 4-way fluorescence-activated cell sorting. FcaGHV1gB qPCR was performed on DNA extracted from purified fractions and whole blood longitudinally. FcaGHV1 DNA was detected in CD21+, CD4+, CD8+, but not CD14+ cells. Variation in whole blood load, up to 19,788 copies/10{sup 6}cells, was detected in individual cats over time. FcaGHV1 DNA was undetectable in one cat on one occasion highlighting that qPCR of whole blood from a single time point will not detect all cases of FcaGHV1 infection. Further investigation of the role of FcaGHV1 in feline lymphoid malignancies is warranted. -- Highlights: •FcaGHV1 DNA detected in circulating B and T lymphocytes in domestic cats. •Peripheral FcaGHV1 load fluctuates widely in healthy, chronically-infected cats. •qPCR of blood taken at a single time-point will fail to detect some FcaGHV-infected cats. •A role for FcaGHV1 in FIV-associated lymphoid malignancies is supported.

  20. Detection of Felis catus gammaherpesvirus 1 (FcaGHV1) in peripheral blood B- and T-lymphocytes in asymptomatic, naturally-infected domestic cats

    International Nuclear Information System (INIS)

    McLuckie, Alicia J.; Barrs, Vanessa R.; Smith, Adrian L.; Beatty, Julia A.

    2016-01-01

    The domestic cat is natural host to both feline immunodeficiency virus and Felis catus gammaherpesvirus 1 (FcaGHV1). Comparative data suggest that these agents might act as synergistic copathogens in feline AIDS-related lymphoma. To identify leucocyte subsets harbouring gammaherpesvirus DNA, whole blood from 5 healthy, FcaGHV1-infected cats was labelled with monoclonal antibodies to feline CD21, CD4, CD8 and CD14 for 4-way fluorescence-activated cell sorting. FcaGHV1gB qPCR was performed on DNA extracted from purified fractions and whole blood longitudinally. FcaGHV1 DNA was detected in CD21+, CD4+, CD8+, but not CD14+ cells. Variation in whole blood load, up to 19,788 copies/10 6 cells, was detected in individual cats over time. FcaGHV1 DNA was undetectable in one cat on one occasion highlighting that qPCR of whole blood from a single time point will not detect all cases of FcaGHV1 infection. Further investigation of the role of FcaGHV1 in feline lymphoid malignancies is warranted. -- Highlights: •FcaGHV1 DNA detected in circulating B and T lymphocytes in domestic cats. •Peripheral FcaGHV1 load fluctuates widely in healthy, chronically-infected cats. •qPCR of blood taken at a single time-point will fail to detect some FcaGHV-infected cats. •A role for FcaGHV1 in FIV-associated lymphoid malignancies is supported.