WorldWideScience

Sample records for peripheral vision performance

  1. Beauty and cuteness in peripheral vision

    Science.gov (United States)

    Kuraguchi, Kana; Ashida, Hiroshi

    2015-01-01

    Guo et al. (2011) showed that attractiveness was detectable in peripheral vision. Since there are different types of attractiveness (Rhodes, 2006), we investigated how beauty and cuteness are detected in peripheral vision with a brief presentation. Participants (n = 45) observed two Japanese female faces for 100 ms, then were asked to respond which face was more beautiful (or cuter). The results indicated that both beauty and cuteness were detectable in peripheral vision, but not in the same manner. Discrimination rates for judging beauty were invariant in peripheral and central vision, while discrimination rates for judging cuteness declined in peripheral vision as compared with central vision. This was not explained by lower resolution in peripheral vision. In addition, for male participants, it was more difficult to judge cuteness than beauty in peripheral vision, thus suggesting that gender differences can have a certain effect when judging cuteness. Therefore, central vision might be suitable for judging cuteness while judging beauty might not be affected by either central or peripheral vision. This might be related with the functional difference between beauty and cuteness. PMID:25999883

  2. Peripheral vision of youths with low vision: motion perception, crowding, and visual search.

    Science.gov (United States)

    Tadin, Duje; Nyquist, Jeffrey B; Lusk, Kelly E; Corn, Anne L; Lappin, Joseph S

    2012-08-24

    Effects of low vision on peripheral visual function are poorly understood, especially in children whose visual skills are still developing. The aim of this study was to measure both central and peripheral visual functions in youths with typical and low vision. Of specific interest was the extent to which measures of foveal function predict performance of peripheral tasks. We assessed central and peripheral visual functions in youths with typical vision (n = 7, ages 10-17) and low vision (n = 24, ages 9-18). Experimental measures used both static and moving stimuli and included visual crowding, visual search, motion acuity, motion direction discrimination, and multitarget motion comparison. In most tasks, visual function was impaired in youths with low vision. Substantial differences, however, were found both between participant groups and, importantly, across different tasks within participant groups. Foveal visual acuity was a modest predictor of peripheral form vision and motion sensitivity in either the central or peripheral field. Despite exhibiting normal motion discriminations in fovea, motion sensitivity of youths with low vision deteriorated in the periphery. This contrasted with typically sighted participants, who showed improved motion sensitivity with increasing eccentricity. Visual search was greatly impaired in youths with low vision. Our results reveal a complex pattern of visual deficits in peripheral vision and indicate a significant role of attentional mechanisms in observed impairments. These deficits were not adequately captured by measures of foveal function, arguing for the importance of independently assessing peripheral visual function.

  3. Peripheral Vision of Youths with Low Vision: Motion Perception, Crowding, and Visual Search

    Science.gov (United States)

    Tadin, Duje; Nyquist, Jeffrey B.; Lusk, Kelly E.; Corn, Anne L.; Lappin, Joseph S.

    2012-01-01

    Purpose. Effects of low vision on peripheral visual function are poorly understood, especially in children whose visual skills are still developing. The aim of this study was to measure both central and peripheral visual functions in youths with typical and low vision. Of specific interest was the extent to which measures of foveal function predict performance of peripheral tasks. Methods. We assessed central and peripheral visual functions in youths with typical vision (n = 7, ages 10–17) and low vision (n = 24, ages 9–18). Experimental measures used both static and moving stimuli and included visual crowding, visual search, motion acuity, motion direction discrimination, and multitarget motion comparison. Results. In most tasks, visual function was impaired in youths with low vision. Substantial differences, however, were found both between participant groups and, importantly, across different tasks within participant groups. Foveal visual acuity was a modest predictor of peripheral form vision and motion sensitivity in either the central or peripheral field. Despite exhibiting normal motion discriminations in fovea, motion sensitivity of youths with low vision deteriorated in the periphery. This contrasted with typically sighted participants, who showed improved motion sensitivity with increasing eccentricity. Visual search was greatly impaired in youths with low vision. Conclusions. Our results reveal a complex pattern of visual deficits in peripheral vision and indicate a significant role of attentional mechanisms in observed impairments. These deficits were not adequately captured by measures of foveal function, arguing for the importance of independently assessing peripheral visual function. PMID:22836766

  4. Mini-review: Far peripheral vision.

    Science.gov (United States)

    Simpson, Michael J

    2017-11-01

    The region of far peripheral vision, beyond 60 degrees of visual angle, is important to the evaluation of peripheral dark shadows (negative dysphotopsia) seen by some intraocular lens (IOL) patients. Theoretical calculations show that the limited diameter of an IOL affects ray paths at large angles, leading to a dimming of the main image for small pupils, and to peripheral illumination by light bypassing the IOL for larger pupils. These effects are rarely bothersome, and cataract surgery is highly successful, but there is a need to improve the characterization of far peripheral vision, for both pseudophakic and phakic eyes. Perimetry is the main quantitative test, but the purpose is to evaluate pathologies rather than characterize vision (and object and image regions are no longer uniquely related in the pseudophakic eye). The maximum visual angle is approximately 105 0 , but there is limited information about variations with age, race, or refractive error (in case there is an unexpected link with the development of myopia), or about how clear cornea, iris location, and the limiting retina are related. Also, the detection of peripheral motion is widely recognized to be important, yet rarely evaluated. Overall, people rarely complain specifically about this visual region, but with "normal" vision including an IOL for >5% of people, and increasing interest in virtual reality and augmented reality, there are new reasons to characterize peripheral vision more completely. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Coaching Peripheral Vision Training for Soccer Athletes

    Science.gov (United States)

    Marques, Nelson Kautzner, Jr.

    2010-01-01

    Brazilian Soccer began developing its current emphasis on peripheral vision in the late 1950s, by initiative of coach of the Canto do Rio Football Club, in Niteroi, Rio de Janeiro, a pioneer in the development of peripheral vision training in soccer players. Peripheral vision training gained world relevance when a young talent from Canto do Rio,…

  6. Peripheral vision benefits spatial learning by guiding eye movements.

    Science.gov (United States)

    Yamamoto, Naohide; Philbeck, John W

    2013-01-01

    The loss of peripheral vision impairs spatial learning and navigation. However, the mechanisms underlying these impairments remain poorly understood. One advantage of having peripheral vision is that objects in an environment are easily detected and readily foveated via eye movements. The present study examined this potential benefit of peripheral vision by investigating whether competent performance in spatial learning requires effective eye movements. In Experiment 1, participants learned room-sized spatial layouts with or without restriction on direct eye movements to objects. Eye movements were restricted by having participants view the objects through small apertures in front of their eyes. Results showed that impeding effective eye movements made subsequent retrieval of spatial memory slower and less accurate. The small apertures also occluded much of the environmental surroundings, but the importance of this kind of occlusion was ruled out in Experiment 2 by showing that participants exhibited intact learning of the same spatial layouts when luminescent objects were viewed in an otherwise dark room. Together, these findings suggest that one of the roles of peripheral vision in spatial learning is to guide eye movements, highlighting the importance of spatial information derived from eye movements for learning environmental layouts.

  7. Agnosic vision is like peripheral vision, which is limited by crowding.

    Science.gov (United States)

    Strappini, Francesca; Pelli, Denis G; Di Pace, Enrico; Martelli, Marialuisa

    2017-04-01

    Visual agnosia is a neuropsychological impairment of visual object recognition despite near-normal acuity and visual fields. A century of research has provided only a rudimentary account of the functional damage underlying this deficit. We find that the object-recognition ability of agnosic patients viewing an object directly is like that of normally-sighted observers viewing it indirectly, with peripheral vision. Thus, agnosic vision is like peripheral vision. We obtained 14 visual-object-recognition tests that are commonly used for diagnosis of visual agnosia. Our "standard" normal observer took these tests at various eccentricities in his periphery. Analyzing the published data of 32 apperceptive agnosia patients and a group of 14 posterior cortical atrophy (PCA) patients on these tests, we find that each patient's pattern of object recognition deficits is well characterized by one number, the equivalent eccentricity at which our standard observer's peripheral vision is like the central vision of the agnosic patient. In other words, each agnosic patient's equivalent eccentricity is conserved across tests. Across patients, equivalent eccentricity ranges from 4 to 40 deg, which rates severity of the visual deficit. In normal peripheral vision, the required size to perceive a simple image (e.g., an isolated letter) is limited by acuity, and that for a complex image (e.g., a face or a word) is limited by crowding. In crowding, adjacent simple objects appear unrecognizably jumbled unless their spacing exceeds the crowding distance, which grows linearly with eccentricity. Besides conservation of equivalent eccentricity across object-recognition tests, we also find conservation, from eccentricity to agnosia, of the relative susceptibility of recognition of ten visual tests. These findings show that agnosic vision is like eccentric vision. Whence crowding? Peripheral vision, strabismic amblyopia, and possibly apperceptive agnosia are all limited by crowding, making it

  8. The role of peripheral vision in implicit contextual cuing.

    Science.gov (United States)

    van Asselen, Marieke; Castelo-Branco, Miguel

    2009-01-01

    Implicit contextual cuing refers to the ability to learn the association between contextual information of our environment and a specific target, which can be used to guide attention during visual search. It was recently suggested that the storage of a snapshot image of the local context of a target underlies implicit contextual cuing. To make such a snapshot, it is necessary to use peripheral vision. In order to test whether peripheral vision can underlie implicit contextual cuing, we used a covert visual search task, in which participants were required to indicate the orientation of a target stimulus while foveating a fixation cross. The response times were shorter when the configuration of the stimuli was repeated than when the configuration was new. Importantly, this effect was still found after 10 days, indicating that peripherally perceived spatial context information can be stored in memory for long periods of time. These results indicate that peripheral vision can be used to make a snapshot of the local context of a target.

  9. Deployment of spatial attention to words in central and peripheral vision.

    Science.gov (United States)

    Ducrot, Stéphanie; Grainger, Jonathan

    2007-05-01

    Four perceptual identification experiments examined the influence of spatial cues on the recognition of words presented in central vision (with fixation on either the first or last letter of the target word) and in peripheral vision (displaced left or right of a central fixation point). Stimulus location had a strong effect on word identification accuracy in both central and peripheral vision, showing a strong right visual field superiority that did not depend on eccentricity. Valid spatial cues improved word identification for peripherally presented targets but were largely ineffective for centrally presented targets. Effects of spatial cuing interacted with visual field effects in Experiment 1, with valid cues reducing the right visual field superiority for peripherally located targets, but this interaction was shown to depend on the type of neutral cue. These results provide further support for the role of attentional factors in visual field asymmetries obtained with targets in peripheral vision but not with centrally presented targets.

  10. The Development of Peripheral Vision in Infants.

    Science.gov (United States)

    Guez, Jean R.

    This study investigated the extent of infant peripheral vision, specifically the extent of infants' constricted field, or tunnel vision. Thirteen infants, 2 to 5 months old, were tested using a psychophysical procedure to obtain contrast sensitivity thresholds at four retinal loci (-40, -15, +15, +40 deg.). Infants were placed in an infant bed in…

  11. Peripheral visual performance enhancement by neurofeedback training.

    Science.gov (United States)

    Nan, Wenya; Wan, Feng; Lou, Chin Ian; Vai, Mang I; Rosa, Agostinho

    2013-12-01

    Peripheral visual performance is an important ability for everyone, and a positive inter-individual correlation is found between the peripheral visual performance and the alpha amplitude during the performance test. This study investigated the effect of alpha neurofeedback training on the peripheral visual performance. A neurofeedback group of 13 subjects finished 20 sessions of alpha enhancement feedback within 20 days. The peripheral visual performance was assessed by a new dynamic peripheral visual test on the first and last training day. The results revealed that the neurofeedback group showed significant enhancement of the peripheral visual performance as well as the relative alpha amplitude during the peripheral visual test. It was not the case in the non-neurofeedback control group, which performed the tests within the same time frame as the neurofeedback group but without any training sessions. These findings suggest that alpha neurofeedback training was effective in improving peripheral visual performance. To the best of our knowledge, this is the first study to show evidence for performance improvement in peripheral vision via alpha neurofeedback training.

  12. Training improves reading speed in peripheral vision: is it due to attention?

    Science.gov (United States)

    Lee, Hye-Won; Kwon, Miyoung; Legge, Gordon E; Gefroh, Joshua J

    2010-06-01

    Previous research has shown that perceptual training in peripheral vision, using a letter-recognition task, increases reading speed and letter recognition (S. T. L. Chung, G. E. Legge, & S. H. Cheung, 2004). We tested the hypothesis that enhanced deployment of spatial attention to peripheral vision explains this training effect. Subjects were pre- and post-tested with 3 tasks at 10° above and below fixation-RSVP reading speed, trigram letter recognition (used to construct visual-span profiles), and deployment of spatial attention (measured as the benefit of a pre-cue for target position in a lexical-decision task). Groups of five normally sighted young adults received 4 days of trigram letter-recognition training in upper or lower visual fields, or central vision. A control group received no training. Our measure of deployment of spatial attention revealed visual-field anisotropies; better deployment of attention in the lower field than the upper, and in the lower-right quadrant compared with the other three quadrants. All subject groups exhibited slight improvement in deployment of spatial attention to peripheral vision in the post-test, but this improvement was not correlated with training-related increases in reading speed and the size of visual-span profiles. Our results indicate that improved deployment of spatial attention to peripheral vision does not account for improved reading speed and letter recognition in peripheral vision.

  13. Auditory and visual reaction time and peripheral field of vision in helmet users

    Directory of Open Access Journals (Sweden)

    Abbupillai Adhilakshmi

    2016-12-01

    Full Text Available Background: The incidence of fatal accidents are more in two wheeler drivers compared to four wheeler drivers. Head injury is of serious concern when recovery and prognosis of the patients are warranted, helmets are being used for safety purposes by moped, scooters and motorcycle drivers. Although, helmets are designed with cushioning effect to prevent head injuries but there are evidences of increase risk of neck injuries and reduced peripheral vision and hearing in helmet users. A complete full coverage helmets provide about less than 3 percent restrictions in horizontal peripheral visual field compared to rider without helmet. The standard company patented ergonomically designed helmets which does not affect the peripheral vision neither auditory reaction time. Objective: This pilot study aimed to evaluate the peripheral field of vision and auditory and visual reaction time in a hypertensive, diabetic and healthy male and female in order to have a better insight of protective characteristics of helmet in health and disease. Method: This pilot study carried out on age matched male of one healthy, one hypertensive and one diabetic and female subject of one healthy, one hypertensive and one diabetics. The field of vision was assessed by Lister’s perimeter whereas auditory and visual reaction time was recorded with response analyser. Result : Gender difference was not noted in peripheral field of vision but mild difference was found in auditory reaction time for high frequency and visual reaction time for both red and green colour in healthy control. But lateral and downward peripheral visual field was found reduced whereas auditory and visual reaction time was found increased in both hypertensive and diabetic subject in both sexes. Conclusion: Peripheral vision, auditory reaction time and visual reaction time in hypertensive and diabetics may lead to vulnerable accident. Helmet use has proven to reduce extent of injury in motorcyclist and

  14. Training improves reading speed in peripheral vision: Is it due to attention?

    OpenAIRE

    Lee, Hye-Won; Kwon, MiYoung; Legge, Gordon E.; Gefroh, Joshua J.

    2010-01-01

    Previous research has shown that perceptual training in peripheral vision, using a letter-recognition task, increases reading speed and letter recognition (Chung, Legge, & Cheung, 2004). We tested the hypothesis that enhanced deployment of spatial attention to peripheral vision explains this training effect. Subjects were pre- and post-tested with 3 tasks at 10° above and below fixation—RSVP reading speed, trigram letter recognition (used to construct visual-span profiles), and deployment of ...

  15. Foveal and peripheral fields of vision influences perceptual skill in anticipating opponents' attacking position in volleyball.

    Science.gov (United States)

    Schorer, Jörg; Rienhoff, Rebecca; Fischer, Lennart; Baker, Joseph

    2013-09-01

    The importance of perceptual-cognitive expertise in sport has been repeatedly demonstrated. In this study we examined the role of different sources of visual information (i.e., foveal versus peripheral) in anticipating volleyball attack positions. Expert (n = 11), advanced (n = 13) and novice (n = 16) players completed an anticipation task that involved predicting the location of volleyball attacks. Video clips of volleyball attacks (n = 72) were spatially and temporally occluded to provide varying amounts of information to the participant. In addition, participants viewed the attacks under three visual conditions: full vision, foveal vision only, and peripheral vision only. Analysis of variance revealed significant between group differences in prediction accuracy with higher skilled players performing better than lower skilled players. Additionally, we found significant differences between temporal and spatial occlusion conditions. Both of those factors interacted separately, but not combined with expertise. Importantly, for experts the sum of both fields of vision was superior to either source in isolation. Our results suggest different sources of visual information work collectively to facilitate expert anticipation in time-constrained sports and reinforce the complexity of expert perception.

  16. Which visual sight skill tested and developed the interaction between central and peripheral vision case duels dribbling soccer skills

    Directory of Open Access Journals (Sweden)

    Zerf Mohammed

    2016-09-01

    Full Text Available The present paper analyses the effects of visual keep sight to test and develop the interaction between central and peripheral vision the case of duels dribbling among soccer under 17 years. Where This research aims to propose a method evaluating and coaching this skill in the absence of laboratory tests and virtual visual exercises as a way for Algerian coaches to control the progress of their players. From the principle that the team which wins the most duels has the best chance of winning the game. [1] Our research supports the hypothesis which confirms in one hand that Dynamic visual acuity is the combine between Peripheral and Central vision to have one eye on the ball and the other on the defined [2] . While some authors confirm that the Top-class football players do not watch their steps, but dribble with their heads up [3]. Whereas Previous studies confirm estimate of distance ball foot player is the strategy to master this skill [4] which requires the involvement of the commitment of peripheral vision for information and central vision to master the ball [5]. From the proof and results statistics applied in the current study, we confirm that narrow spaces require the interaction of central vision than peripheral vision. Otherwise, free spaces require peripheral vision than the central vision. Which leaves us to confirm that peripheral vision in the limited space [6] can suffer because the player needs to pay close attention to each contact with the ball [7].

  17. Lateralized discrimination of emotional scenes in peripheral vision.

    Science.gov (United States)

    Calvo, Manuel G; Rodríguez-Chinea, Sandra; Fernández-Martín, Andrés

    2015-03-01

    This study investigates whether there is lateralized processing of emotional scenes in the visual periphery, in the absence of eye fixations; and whether this varies with emotional valence (pleasant vs. unpleasant), specific emotional scene content (babies, erotica, human attack, mutilation, etc.), and sex of the viewer. Pairs of emotional (positive or negative) and neutral photographs were presented for 150 ms peripherally (≥6.5° away from fixation). Observers judged on which side the emotional picture was located. Low-level image properties, scene visual saliency, and eye movements were controlled. Results showed that (a) correct identification of the emotional scene exceeded the chance level; (b) performance was more accurate and faster when the emotional scene appeared in the left than in the right visual field; (c) lateralization was equivalent for females and males for pleasant scenes, but was greater for females and unpleasant scenes; and (d) lateralization occurred similarly for different emotional scene categories. These findings reveal discrimination between emotional and neutral scenes, and right brain hemisphere dominance for emotional processing, which is modulated by sex of the viewer and scene valence, and suggest that coarse affective significance can be extracted in peripheral vision.

  18. Facilitation of contrast detection in near-peripheral vision.

    Science.gov (United States)

    Giorgi, Robert G; Soong, Grace P; Woods, Russell L; Peli, Eli

    2004-12-01

    Foveal detection of a Gabor patch (target) is facilitated by collinear, displaced high-contrast flankers. Polat and Sagi reported that the same phenomenon occurred in the periphery, but no data were presented [Proc. Natl. Acad. Sci. 91 (1994) 1206]. Others have found no facilitation in a limited number of conditions tested. To resolve this apparent conflict, we measured lateral facilitation in the near-periphery using a range of stimulus parameters. We found facilitation for a range of target-flanker distances for peripheral eccentricities up to 6 degrees , but the magnitude of the effect was less than found in central vision. Facilitation varied across subjects and with spatial frequency. Flanker contrast had no effect over the range evaluated (10-80%). Equal facilitation was found for two global arrangements of the stimulus pattern. Facilitation was found using a temporal, but not a spatial two-alternative forced-choice paradigm, accounting for the different results among previous studies. This finding supports previous indications of the role of attention in altering such facilitation. The value of facilitation from lateral interactions for persons with central vision impairment, who have to shift their attention to a peripheral locus constantly, needs to be examined.

  19. Towards an assistive peripheral visual prosthesis for long-term treatment of retinitis pigmentosa: evaluating mobility performance in immersive simulations

    Science.gov (United States)

    Zapf, Marc Patrick H.; Boon, Mei-Ying; Matteucci, Paul B.; Lovell, Nigel H.; Suaning, Gregg J.

    2015-06-01

    Objective. The prospective efficacy of a future peripheral retinal prosthesis complementing residual vision to raise mobility performance in non-end stage retinitis pigmentosa (RP) was evaluated using simulated prosthetic vision (SPV). Approach. Normally sighted volunteers were fitted with a wide-angle head-mounted display and carried out mobility tasks in photorealistic virtual pedestrian scenarios. Circumvention of low-lying obstacles, path following, and navigating around static and moving pedestrians were performed either with central simulated residual vision of 10° alone or enhanced by assistive SPV in the lower and lateral peripheral visual field (VF). Three layouts of assistive vision corresponding to hypothetical electrode array layouts were compared, emphasizing higher visual acuity, a wider visual angle, or eccentricity-dependent acuity across an intermediate angle. Movement speed, task time, distance walked and collisions with the environment were analysed as performance measures. Main results. Circumvention of low-lying obstacles was improved with all tested configurations of assistive SPV. Higher-acuity assistive vision allowed for greatest improvement in walking speeds—14% above that of plain residual vision, while only wide-angle and eccentricity-dependent vision significantly reduced the number of collisions—both by 21%. Navigating around pedestrians, there were significant reductions in collisions with static pedestrians by 33% and task time by 7.7% with the higher-acuity layout. Following a path, higher-acuity assistive vision increased walking speed by 9%, and decreased collisions with stationary cars by 18%. Significance. The ability of assistive peripheral prosthetic vision to improve mobility performance in persons with constricted VFs has been demonstrated. In a prospective peripheral visual prosthesis, electrode array designs need to be carefully tailored to the scope of tasks in which a device aims to assist. We posit that maximum

  20. Deaf and Hearing Children: A Comparison of Peripheral Vision Development

    Science.gov (United States)

    Codina, Charlotte; Buckley, David; Port, Michael; Pascalis, Olivier

    2011-01-01

    This study investigated peripheral vision (at least 30[degrees] eccentric to fixation) development in profoundly deaf children without cochlear implantation, and compared this to age-matched hearing controls as well as to deaf and hearing adult data. Deaf and hearing children between the ages of 5 and 15 years were assessed using a new,…

  1. Unconsciously perceived fear in peripheral vision alerts the limbic system: a MEG study.

    Directory of Open Access Journals (Sweden)

    Dimitri J Bayle

    Full Text Available BACKGROUND: In ecological situations, threatening stimuli often come out from the peripheral vision. Such aggressive messages must trigger rapid attention to the periphery to allow a fast and adapted motor reaction. Several clues converge to hypothesize that peripheral danger presentation can trigger off a fast arousal network potentially independent of the consciousness spot. METHODOLOGY/PRINCIPAL FINDINGS: In the present MEG study, spatio-temporal dynamics of the neural processing of danger related stimuli were explored as a function of the stimuli position in the visual field. Fearful and neutral faces were briefly presented in the central or peripheral visual field, and were followed by target faces stimuli. An event-related beamformer source analysis model was applied in three time windows following the first face presentations: 80 to 130 ms, 140 to 190 ms, and 210 to 260 ms. The frontal lobe and the right internal temporal lobe part, including the amygdala, reacted as soon as 80 ms of latency to fear occurring in the peripheral vision. For central presentation, fearful faces evoked the classical neuronal activity along the occipito-temporal visual pathway between 140 and 190 ms. CONCLUSIONS: Thus, the high spatio-temporal resolution of MEG allowed disclosing a fast response of a network involving medial temporal and frontal structures in the processing of fear related stimuli occurring unconsciously in the peripheral visual field. Whereas centrally presented stimuli are precisely processed by the ventral occipito-temporal cortex, the related-to-danger stimuli appearing in the peripheral visual field are more efficient to produce a fast automatic alert response possibly conveyed by subcortical structures.

  2. The role of peripheral vision in saccade planning: learning from people with tunnel vision.

    Science.gov (United States)

    Luo, Gang; Vargas-Martin, Fernando; Peli, Eli

    2008-12-22

    Both visually salient and top-down information are important in eye movement control, but their relative roles in the planning of daily saccades are unclear. We investigated the effect of peripheral vision loss on saccadic behaviors in patients with tunnel vision (visual field diameters 7 degrees-16 degrees) in visual search and real-world walking experiments. The patients made up to two saccades per second to their pre-saccadic blind areas, about half of which had no overlap between the post- and pre-saccadic views. In the visual search experiment, visual field size and the background (blank or picture) did not affect the saccade sizes and direction of patients (n = 9). In the walking experiment, the patients (n = 5) and normal controls (n = 3) had similar distributions of saccade sizes and directions. These findings might provide a clue about the large extent of the top-down mechanism influence on eye movement control.

  3. Unsold is unseen … or is it? Examining the role of peripheral vision in the consumer choice process using eye-tracking methodology.

    Science.gov (United States)

    Wästlund, Erik; Shams, Poja; Otterbring, Tobias

    2018-01-01

    In visual marketing, the truism that "unseen is unsold" means that products that are not noticed will not be sold. This truism rests on the idea that the consumer choice process is heavily influenced by visual search. However, given that the majority of available products are not seen by consumers, this article examines the role of peripheral vision in guiding attention during the consumer choice process. In two eye-tracking studies, one conducted in a lab facility and the other conducted in a supermarket, the authors investigate the role and limitations of peripheral vision. The results show that peripheral vision is used to direct visual attention when discriminating between target and non-target objects in an eye-tracking laboratory. Target and non-target similarity, as well as visual saliency of non-targets, constitute the boundary conditions for this effect, which generalizes from instruction-based laboratory tasks to preference-based choice tasks in a real supermarket setting. Thus, peripheral vision helps customers to devote a larger share of attention to relevant products during the consumer choice process. Taken together, the results show how the creation of consideration set (sets of possible choice options) relies on both goal-directed attention and peripheral vision. These results could explain how visually similar packaging positively influences market leaders, while making novel brands almost invisible on supermarket shelves. The findings show that even though unsold products might be unseen, in the sense that they have not been directly observed, they might still have been evaluated and excluded by means of peripheral vision. This article is based on controlled lab experiments as well as a field study conducted in a complex retail environment. Thus, the findings are valid both under controlled and ecologically valid conditions. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. Effect of peripheral vision training on the attack of beginner indoor soccer players: a study during competition

    Directory of Open Access Journals (Sweden)

    Nelson Kautzner Marques Junior

    2009-01-01

    Full Text Available This study was conducted within the context of Human Motor Skill Science, in the area of Biophysical Dimension and following the research line of the Study of Learning Mechanisms and Processes and of Motor Conduct within the epistemological construct of phenomenological explanation. The objective of this study was to investigate peripheral vision training (PVT and its effect on attack runs during indoor soccer, taking into account dominant laterality (brain hemisphere function in both learning speed andoffensive skills. Ten beginner indoor soccer players aged 10.4 ± 2.31 years, from Lar da Criança Padre Franz Neumair, Ititioca, Niterói, Rio de Janeiro, Brazil, participated in the study. The boys were divided into an experimental group (EG, n = 5 and a controlgroup (CG, n = 5 with similar dominant laterality (brain hemisphere function (H (EG: 80% left H and 20% right H, CG: 60% left H and 40% right H. The players underwent nine training sessions, followed by a championship, and then six additional sessions, followed by a second championship. Each championship was filmed for scoutvideo analysis. Two-way ANOVA revealed a significant difference in peripheral vision during offensive runs between CG and EG, with marked acquisition of peripheral vision in EG. The quality of the attack runs was significant (two-way ANOVA. EG was the better team at the beginning of the attack runs and during attack development, whereas CG was better at attack finalization during the first championship. EG showed more competence in attack run finalization during the second championship. No significant difference in the number of goals scored was observed between the two groups (two-wayANOVA, p>0.05. The frequency of participation in the training sessions was significant (t-test for independent samples, p≤0.05, with EG attending more sessions. In conclusion, EG acquired peripheral vision, a finding suggesting that PVT improves the attack capacity of indoor soccer

  5. Effect of peripheral vision training on the attack of beginner indoor soccer players: a study during competition

    Directory of Open Access Journals (Sweden)

    Nelson Kautzner Marques Junior

    2009-01-01

    Full Text Available http://dx.doi.org/10.5007/1980-0037.2009v11n1p119   In the area of Biophysical Dimension and following the research line of the Study of Learning Mechanisms and Processes and of Motor Conduct within the epistemological construct of phenomenological explanation. The objective of this study was to investigate peripheral vision training (PVT and its effect on attack runs during indoor soccer, taking into account dominant laterality (brain hemisphere function in both learning speed and offensive skills. Ten beginner indoor soccer players aged 10.4 ± 2.31 years, from Lar da Criança Padre Franz Neumair, Ititioca, Niterói, Rio de Janeiro, Brazil, participated in the study. The boys were divided into an experimental group (EG, n = 5 and a control group (CG, n = 5 with similar dominant laterality (brain hemisphere function (H (EG: 80% left H and 20% right H, CG: 60% left H and 40% right H. The players underwent nine training sessions, followed by a championship, and then six additional sessions, followed by a second championship. Each championship was filmed for scout video analysis. Two-way ANOVA revealed a significant difference in peripheral vision during offensive runs between CG and EG, with marked acquisition of peripheral vision in EG. The quality of the attack runs was significant (two-way ANOVA. EG was the better team at the beginning of the attack runs and during attack development, whereas CG was better at attack finalization during the first championship. EG showed more competence in attack run finalization during the second championship. No significant difference in the number of goals scored was observed between the two groups (two-way ANOVA, p>0.05. The frequency of participation in the training sessions was significant (t-test for independent samples, p≤0.05, with EG attending more sessions. In conclusion, EG acquired peripheral vision, a finding suggesting that PVT improves the attack capacity of indoor soccer players.

  6. 75 FR 9480 - Qualification of Drivers; Exemption Applications; Vision

    Science.gov (United States)

    2010-03-02

    ... injury sustained as a child. The best corrected visual acuity in his right eye is light-perception only... medical opinion, Mr. Williford has sufficient visual acuity, color vision and peripheral vision to perform...

  7. Examining Vision and Attention in Sports Performance Using a Gaze-Contingent Paradigm

    Directory of Open Access Journals (Sweden)

    Donghyun Ryu

    2012-10-01

    Full Text Available In time-constrained activities, such as competitive sports, the rapid acquisition and comprehension of visual information is vital for successful performance. Currently our understanding of how and what visual information is acquired and how this changes with skill development is quite rudimentary. Interpretation of eye movement behaviour is limited by uncertainties surrounding the relationship between attention, line-of-gaze data, and the mechanism of information pick-up from different sectors of the visual field. We used gaze-contingent display methodology to provide a selective information presentation to the central and peripheral parts of the visual field while performing a decision-making task. Eleven skilled and 11 less-skilled players watched videos of basketball scenarios under three different vision conditions (tunnel, masked, and full vision and in a forced-choice paradigm responded whether it was more appropriate for the ball carrier to pass or drive. In the tunnel and mask conditions vision was selectively restricted to, or occluded from, 5o around the line of gaze respectively. The skilled players showed significantly higher response accuracy and faster response times compared to their lesser skilled counterparts irrespective of the vision condition, demonstrating the skilled players' superiority in information extraction irrespective of the segment of visual field they rely on. Findings suggest that the capability to interpret visual information appears to be the key limiting factor to expert performance rather than the sector of the visual field in which the information is detected.

  8. Assistive peripheral phosphene arrays deliver advantages in obstacle avoidance in simulated end-stage retinitis pigmentosa: a virtual-reality study

    Science.gov (United States)

    Zapf, Marc Patrick H.; Boon, Mei-Ying; Lovell, Nigel H.; Suaning, Gregg J.

    2016-04-01

    Objective. The prospective efficacy of peripheral retinal prostheses for guiding orientation and mobility in the absence of residual vision, as compared to an implant for the central visual field (VF), was evaluated using simulated prosthetic vision (SPV). Approach. Sighted volunteers wearing a head-mounted display performed an obstacle circumvention task under SPV. Mobility and orientation performance with three layouts of prosthetic vision were compared: peripheral prosthetic vision of higher visual acuity (VA) but limited VF, of wider VF but limited VA, as well as centrally restricted prosthetic vision. Learning curves using these layouts were compared fitting an exponential model to the mobility and orientation measures. Main results. Using peripheral layouts, performance was superior to the central layout. Walking speed with both higher-acuity and wider-angle layouts was 5.6% higher, and mobility errors reduced by 46.4% and 48.6%, respectively, as compared to the central layout. The wider-angle layout yielded the least number of collisions, 63% less than the higher-acuity and 73% less than the central layout. Using peripheral layouts, the number of visual-scanning related head movements was 54.3% (higher-acuity) and 60.7% (wider-angle) lower, as compared to the central layout, and the ratio of time standing versus time walking was 51.9% and 61.5% lower, respectively. Learning curves did not differ between layouts, except for time standing versus time walking, where both peripheral layouts achieved significantly lower asymptotic values compared to the central layout. Significance. Beyond complementing residual vision for an improved performance, peripheral prosthetic vision can effectively guide mobility in the later stages of retinitis pigmentosa (RP) without residual vision. Further, the temporal dynamics of learning peripheral and central prosthetic vision are similar. Therefore, development of a peripheral retinal prosthesis and early implantation to

  9. Peripheral vision and perceptual asymmetries in young and older martial arts athletes and nonathletes.

    Science.gov (United States)

    Muiños, Mónica; Ballesteros, Soledad

    2014-11-01

    The present study investigated peripheral vision (PV) and perceptual asymmetries in young and older martial arts athletes (judo and karate athletes) and compared their performance with that of young and older nonathletes. Stimuli were dots presented at three different eccentricities along the horizontal, oblique, and vertical diameters and three interstimulus intervals. Experiment 1 showed that although the two athlete groups were faster in almost all conditions, karate athletes performed significantly better than nonathlete participants when stimuli were presented in the peripheral visual field. Experiment 2 showed that older participants who had practiced a martial art at a competitive level when they were young were significantly faster than sedentary older adults of the same age. The practiced sport (judo or karate) did not affect performance differentially, suggesting that it is the practice of martial arts that is the crucial factor, rather than the type of martial art. Importantly, older athletes lose their PV advantage, as compared with young athletes. Finally, we found that physical activity (young and older athletes) and age (young and older adults) did not alter the visual asymmetries that vary as a function of spatial location; all participants were faster for stimuli presented along the horizontal than for those presented along the vertical meridian and for those presented at the lower rather than at the upper locations within the vertical meridian. These results indicate that the practice of these martial arts is an effective way of counteracting the processing speed decline of visual stimuli appearing at any visual location and speed.

  10. An Exploratory Study of the Potential Effects of Vision Training on Concussion Incidence in Football

    OpenAIRE

    Joseph F. Clark, PHD, ATC; Pat Graman, MA, ATC; James K. Ellis, OD; Robert E. Mangine, MEd, PT, ATC; Joesph T. Rauch, DPT, SCS, ATC; Ben Bixenmann, MD; Kimberly A. Hasselfeld, MS; Jon G. Divine, MD; Angelo J. Colosimo, MD; Gregory D. Myer, PhD, FACSM

    2015-01-01

    Background: Vision training has become a component of sports enhancement training; however, quantifiable and validated improvement in visual performance has not been clearly demonstrated. In addition, there is minimal literature related to the effects of vision training on sports performance and injury risk reduction. The purpose of the current investigation was to determine the effects of vision training on peripheral vision and concussion incidence. Methods: Vision training was initiate...

  11. Biofeedback for Better Vision

    Science.gov (United States)

    1990-01-01

    Biofeedtrac, Inc.'s Accommotrac Vision Trainer, invented by Dr. Joseph Trachtman, is based on vision research performed by Ames Research Center and a special optometer developed for the Ames program by Stanford Research Institute. In the United States, about 150 million people are myopes (nearsighted), who tend to overfocus when they look at distant objects causing blurry distant vision, or hyperopes (farsighted), whose vision blurs when they look at close objects because they tend to underfocus. The Accommotrac system is an optical/electronic system used by a doctor as an aid in teaching a patient how to contract and relax the ciliary body, the focusing muscle. The key is biofeedback, wherein the patient learns to control a bodily process or function he is not normally aware of. Trachtman claims a 90 percent success rate for correcting, improving or stopping focusing problems. The Vision Trainer has also proved effective in treating other eye problems such as eye oscillation, cross eyes, and lazy eye and in professional sports to improve athletes' peripheral vision and reaction time.

  12. Impact of low vision rehabilitation on functional vision performance of children with visual impairment.

    Science.gov (United States)

    Ganesh, Suma; Sethi, Sumita; Srivastav, Sonia; Chaudhary, Amrita; Arora, Priyanka

    2013-09-01

    To evaluate the impact of low vision rehabilitation on functional vision of children with visual impairment. The LV Prasad-Functional Vision Questionnaire, designed specifically to measure functional performance of visually impaired children of developing countries, was used to assess the level of difficulty in performing various tasks pre and post visual rehabilitation in children with documented visual impairment. Chi-square test was used to assess the impact of rehabilitation intervention on functional vision performance; a P visual acuity prior to the introduction of low vision devices (LVDs) was 0.90 ± 0.05 for distance and for near it was 0.61 ± 0.05. After the intervention, the acuities improved significantly for distance (0.2 ± 0.27; P visual rehabilitation was especially found in those activities related to their studying lifestyle like copying from the blackboard (P visual rehabilitation, especially with those activities which are related to their academic output. It is important for these children to have an early visual rehabilitation to decrease the impairment associated with these decreased visual output and to enhance their learning abilities.

  13. Effect of peripheral vision training on the attack of beginner indoor soccer players: a study during competition

    OpenAIRE

    Nelson Kautzner Marques Junior

    2009-01-01

    This study was conducted within the context of Human Motor Skill Science, in the area of Biophysical Dimension and following the research line of the Study of Learning Mechanisms and Processes and of Motor Conduct within the epistemological construct of phenomenological explanation. The objective of this study was to investigate peripheral vision training (PVT) and its effect on attack runs during indoor soccer, taking into account dominant laterality (brain hemisphere function) in both learn...

  14. Eye guidance during real-world scene search: The role color plays in central and peripheral vision.

    Science.gov (United States)

    Nuthmann, Antje; Malcolm, George L

    2016-01-01

    The visual system utilizes environmental features to direct gaze efficiently when locating objects. While previous research has isolated various features' contributions to gaze guidance, these studies generally used sparse displays and did not investigate how features facilitated search as a function of their location on the visual field. The current study investigated how features across the visual field--particularly color--facilitate gaze guidance during real-world search. A gaze-contingent window followed participants' eye movements, restricting color information to specified regions. Scene images were presented in full color, with color in the periphery and gray in central vision or gray in the periphery and color in central vision, or in grayscale. Color conditions were crossed with a search cue manipulation, with the target cued either with a word label or an exact picture. Search times increased as color information in the scene decreased. A gaze-data based decomposition of search time revealed color-mediated effects on specific subprocesses of search. Color in peripheral vision facilitated target localization, whereas color in central vision facilitated target verification. Picture cues facilitated search, with the effects of cue specificity and scene color combining additively. When available, the visual system utilizes the environment's color information to facilitate different real-world visual search behaviors based on the location within the visual field.

  15. Evaluation of teachers' performance of vision screening in primary

    African Journals Online (AJOL)

    Dr. Petronilla

    Evaluation of Teachers' Performance of Vision Screening in Primary. School Children in Port ... teachers can effectively perform vision screening in school children using ..... may be due to variations in methodology and definitions used, as this ...

  16. Multi-focal Vision and Gaze Control Improve Navigation Performance

    Directory of Open Access Journals (Sweden)

    Kolja Kuehnlenz

    2008-11-01

    Full Text Available Multi-focal vision systems comprise cameras with various fields of view and measurement accuracies. This article presents a multi-focal approach to localization and mapping of mobile robots with active vision. An implementation of the novel concept is done considering a humanoid robot navigation scenario where the robot is visually guided through a structured environment with several landmarks. Various embodiments of multi-focal vision systems are investigated and the impact on navigation performance is evaluated in comparison to a conventional mono-focal stereo set-up. The comparative studies clearly show the benefits of multi-focal vision for mobile robot navigation: flexibility to assign the different available sensors optimally in each situation, enhancement of the visible field, higher localization accuracy, and, thus, better task performance, i.e. path following behavior of the mobile robot. It is shown that multi-focal vision may strongly improve navigation performance.

  17. Effect of peripheral vision training on the attack of beginner indoor soccer players: a study during competition

    OpenAIRE

    Nelson Kautzner Marques Junior

    2009-01-01

    http://dx.doi.org/10.5007/1980-0037.2009v11n1p119   In the area of Biophysical Dimension and following the research line of the Study of Learning Mechanisms and Processes and of Motor Conduct within the epistemological construct of phenomenological explanation. The objective of this study was to investigate peripheral vision training (PVT) and its effect on attack runs during indoor soccer, taking into account dominant laterality (brain hemisphere function) in both learning speed and ...

  18. Profile of Low Vision Population Attending Low Vision Clinic in a Peripheral Eye Hospital in Nepal

    OpenAIRE

    Safal Khanal, BOptom; Pekila Lama, MD

    2013-01-01

    Background: Blindness and low vision are major causes of morbidity and constitute a significant public health problem, both detrimental to the quality of life for the individual and an economic burden on the individual, family, and society in general. People with low vision have the potential for enhancement of functional vision if they receive the appropriate low vision services. The present study aims to determine the profile of the low vision population attending a low vision clinic at a p...

  19. Three-dimensional vision enhances task performance independently of the surgical method.

    Science.gov (United States)

    Wagner, O J; Hagen, M; Kurmann, A; Horgan, S; Candinas, D; Vorburger, S A

    2012-10-01

    Within the next few years, the medical industry will launch increasingly affordable three-dimensional (3D) vision systems for the operating room (OR). This study aimed to evaluate the effect of two-dimensional (2D) and 3D visualization on surgical skills and task performance. In this study, 34 individuals with varying laparoscopic experience (18 inexperienced individuals) performed three tasks to test spatial relationships, grasping and positioning, dexterity, precision, and hand-eye and hand-hand coordination. Each task was performed in 3D using binocular vision for open performance, the Viking 3Di Vision System for laparoscopic performance, and the DaVinci robotic system. The same tasks were repeated in 2D using an eye patch for monocular vision, conventional laparoscopy, and the DaVinci robotic system. Loss of 3D vision significantly increased the perceived difficulty of a task and the time required to perform it, independently of the approach (P robot than with laparoscopy (P = 0.005). In every case, 3D robotic performance was superior to conventional laparoscopy (2D) (P < 0.001-0.015). The more complex the task, the more 3D vision accelerates task completion compared with 2D vision. The gain in task performance is independent of the surgical method.

  20. Visual search in the real world: Color vision deficiency affects peripheral guidance, but leaves foveal verification largely unaffected

    Directory of Open Access Journals (Sweden)

    Günter eKugler

    2015-12-01

    Full Text Available Background: People with color vision deficiencies report numerous limitations in daily life. However, they use basic color terms systematically and in a similar manner as people with people with normal color vision. We hypothesize that a possible explanation for this discrepancy between color perception and behavioral consequences might be found in the gaze behavior of people with color vision deficiency.Methods: A group of participants with color vision deficiencies and a control group performed several search tasks in a naturalistic setting on a lawn.Results: Search performance was similar in both groups in a color-unrelated search task as well as in a search for yellow targets. While searching for red targets, color vision deficient participants exhibited a strongly degraded performance. This was closely matched by the number of fixations on red objects shown by the two groups. Importantly, once they fixated a target, participants with color vision deficiencies exhibited only few identification errors. Conclusions: Participants with color vision deficiencies are not able to enhance their search for red targets on a (green lawn by an efficient guiding mechanism. The data indicate that the impaired guiding is the main influence on search performance, while foveal identification (verification largely unaffected.

  1. Shared vision promotes family firm performance.

    Science.gov (United States)

    Neff, John E

    2015-01-01

    A clear picture of the influential drivers of private family firm performance has proven to be an elusive target. The unique characteristics of private family owned firms necessitate a broader, non-financial approach to reveal firm performance drivers. This research study sought to specify and evaluate the themes that distinguish successful family firms from less successful family firms. In addition, this study explored the possibility that these themes collectively form an effective organizational culture that improves longer-term firm performance. At an organizational level of analysis, research findings identified four significant variables: Shared Vision (PNS), Role Clarity (RCL), Confidence in Management (CON), and Professional Networking (OLN) that positively impacted family firm financial performance. Shared Vision exhibited the strongest positive influence among the significant factors. In addition, Family Functionality (APGAR), the functional integrity of the family itself, exhibited a significant supporting role. Taken together, the variables collectively represent an effective family business culture (EFBC) that positively impacted the long-term financial sustainability of family owned firms. The index of effective family business culture also exhibited potential as a predictive non-financial model of family firm performance.

  2. Shared Vision promotes family firm performance

    Directory of Open Access Journals (Sweden)

    John Edward Neff

    2015-05-01

    Full Text Available A clear picture of the influential drivers of private family firm performance has proven to be an elusive target. The unique characteristics of private family owned firms necessitate a broader, non-financial approach to reveal firm performance drivers. This research study sought to specify and evaluate the themes that distinguish successful family firms from less successful family firms. In addition, this study explored the possibility that these themes collectively form an effective organizational culture that improves longer-term firm performance. At an organizational level of analysis, research findings identified four significant variables: Shared Vision (PNS, Role Clarity (RCL, Confidence in Management (CON, and Professional Networking (OLN that positively impacted family firm financial performance. Shared Vision exhibited the strongest positive influence among the significant factors. In addition, Family Functionality (APGAR, the functional integrity of the family itself exhibited a significant supporting role. Taken together, the variables collectively represent an effective family business culture (EFBC that positively impacted the long-term financial sustainability of family owned firms. The index of effective family business culture also exhibited potential as a predictive non-financial model of family firm performance.

  3. Peripheral neuropathy: an often-overlooked cause of falls in the elderly.

    Science.gov (United States)

    Richardson, J K; Ashton-Miller, J A

    1996-06-01

    Peripheral neuropathy is common in the elderly and results in impairments in distal proprioception and strength that hinder balance and predispose them to falls. The loss of heel reflexes, decreased vibratory sense that improves proximally, impaired position sense at the great toe, and inability to maintain unipedal stance for 10 seconds in three attempts all suggest functionally significant peripheral neuropathy. Physicians can help their patients with peripheral neuropathy to prevent falls by teaching them and their families about peripheral nerve dysfunction and its effects on balance and by advising patients to substitute vision for the lost somatosensory function, correctly use a cane, wear proper shoes and orthotics, and perform balance and upper extremity strengthening exercises.

  4. Reading performance with low-vision aids and vision-related quality of life after macular translocation surgery in patients with age-related macular degeneration.

    Science.gov (United States)

    Nguyen, Nhung X; Besch, Dorothea; Bartz-Schmidt, Karl; Gelisken, Faik; Trauzettel-Klosinski, Susanne

    2007-12-01

    The aim of the present study was to evaluate the power of magnification required, reading performance with low-vision aids and vision-related quality of life with reference to reading ability and ability to carry out day-to-day activities in patients after macular translocation. This study included 15 patients who had undergone macular translocation with 360-degree peripheral retinectomy. The mean length of follow-up was 19.2 +/- 10.8 months (median 11 months). At the final examination, the impact of visual impairment on reading ability and quality of life was assessed according to a modified 9-item questionnaire in conjunction with a comprehensive clinical examination, which included assessment of best corrected visual acuity (BCVA), the magnification power required for reading, use of low-vision aids and reading speed. Patients rated the extent to which low vision restricted their ability to read and participate in other activities that affect quality of life. Responses were scored on a scale of 1.0 (optimum self-evaluation) to 5.0 (very poor). In the operated eye, overall mean postoperative BCVA (distance) was not significantly better than mean preoperative BCVA (0.11 +/- 0.06 and 0.15 +/- 0.08, respectively; p = 0.53). However, 53% of patients reported a subjective increase in visual function after treatment. At the final visit, the mean magnification required was x 7.7 +/- 6.7. A total of 60% of patients needed optical magnifiers for reading and in 40% of patients closed-circuit TV systems were necessary. All patients were able to read newspaper print using adapted low-vision aids at a mean reading speed of 71 +/- 40 words per minute. Mean self-reported scores were 3.2 +/- 1.1 for reading, 2.5 +/- 0.7 for day-to-day activities and 2.7 +/- 3.0 for outdoor walking and using steps or stairs. Patients' levels of dependency were significantly correlated with scores for reading (p = 0.01), day-to-day activities (p vision-related quality of life in patients after

  5. [RESEARCH PROGRESS OF PERIPHERAL NERVE SURGERY ASSISTED BY Da Vinci ROBOTIC SYSTEM].

    Science.gov (United States)

    Shen, Jie; Song, Diyu; Wang, Xiaoyu; Wang, Changjiang; Zhang, Shuming

    2016-02-01

    To summarize the research progress of peripheral nerve surgery assisted by Da Vinci robotic system. The recent domestic and international articles about peripheral nerve surgery assisted by Da Vinci robotic system were reviewed and summarized. Compared with conventional microsurgery, peripheral nerve surgery assisted by Da Vinci robotic system has distinctive advantages, such as elimination of physiological tremors and three-dimensional high-resolution vision. It is possible to perform robot assisted limb nerve surgery using either the traditional brachial plexus approach or the mini-invasive approach. The development of Da Vinci robotic system has revealed new perspectives in peripheral nerve surgery. But it has still been at the initial stage, more basic and clinical researches are still needed.

  6. Development and evaluation of vision rehabilitation devices.

    Science.gov (United States)

    Luo, Gang; Peli, Eli

    2011-01-01

    We have developed a range of vision rehabilitation devices and techniques for people with impaired vision due to either central vision loss or severely restricted peripheral visual field. We have conducted evaluation studies with patients to test the utilities of these techniques in an effort to document their advantages as well as their limitations. Here we describe our work on a visual field expander based on a head mounted display (HMD) for tunnel vision, a vision enhancement device for central vision loss, and a frequency domain JPEG/MPEG based image enhancement technique. All the evaluation studies included visual search paradigms that are suitable for conducting indoor controllable experiments.

  7. SKread predicts handwriting performance in patients with low vision.

    Science.gov (United States)

    Downes, Ken; Walker, Laura L; Fletcher, Donald C

    2015-06-01

    To assess whether performance on the Smith-Kettlewell Reading (SKread) test is a reliable predictor of handwriting performance in patients with low vision. Cross-sectional study. Sixty-six patients at their initial low-vision rehabilitation evaluation. The patients completed all components of a routine low-vision appointment including logMAR acuity, performed the SKread test, and performed a handwriting task. Patients were timed while performing each task and their accuracy was recorded. The handwriting task was performed by having patients write 5 5-letter words into sets of boxes where each letter is separated by a box. The boxes were 15 × 15 mm, and accuracy was scored with 50 points possible from 25 letters: 1 point for each letter within the confines of a box and 1 point if the letter was legible. Correlation analysis was then performed. Median age of participants was 84 (range 54-97) years. Fifty-seven patients (86%) had age-related macular degeneration or some other maculopathy, whereas 9 patients (14%) had visual impairment from media opacity or neurologic impairment. Median Early Treatment Diabetic Retinopathy Study acuity was 20/133 (range 20/22 to 20/1000), and median logMAR acuity was 0.82 (range 0.04-1.70). SKread errors per block correlated with logMAR acuity (r = 0.6), and SKread time per block correlated with logMAR acuity (r = 0.51). SKread errors per block correlated with handwriting task time/accuracy ratio (r = 0.61). SKread time per block correlated with handwriting task time/accuracy ratio (r = 0.7). LogMAR acuity score correlated with handwriting task time/accuracy ratio (r = 0.42). All p values were handwriting performance in patients with low vision better than logMAR acuity. Copyright © 2015 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  8. Common constraints limit Korean and English character recognition in peripheral vision.

    Science.gov (United States)

    He, Yingchen; Kwon, MiYoung; Legge, Gordon E

    2018-01-01

    The visual span refers to the number of adjacent characters that can be recognized in a single glance. It is viewed as a sensory bottleneck in reading for both normal and clinical populations. In peripheral vision, the visual span for English characters can be enlarged after training with a letter-recognition task. Here, we examined the transfer of training from Korean to English characters for a group of bilingual Korean native speakers. In the pre- and posttests, we measured visual spans for Korean characters and English letters. Training (1.5 hours × 4 days) consisted of repetitive visual-span measurements for Korean trigrams (strings of three characters). Our training enlarged the visual spans for Korean single characters and trigrams, and the benefit transferred to untrained English symbols. The improvement was largely due to a reduction of within-character and between-character crowding in Korean recognition, as well as between-letter crowding in English recognition. We also found a negative correlation between the size of the visual span and the average pattern complexity of the symbol set. Together, our results showed that the visual span is limited by common sensory (crowding) and physical (pattern complexity) factors regardless of the language script, providing evidence that the visual span reflects a universal bottleneck for text recognition.

  9. Case Report: Use of Sports and Performance Vision Training to Benefit a Low-vision Patient's Function.

    Science.gov (United States)

    Laby, Daniel M

    2018-05-17

    Despite our inability to attenuate the course of many ocular diseases that can ultimately lead to loss or significantly decreased visual function, this report describes a potential technique to aid such patients in maximizing the use of the vision that remains. The aim of this study was to demonstrate the applicability of utilizing sports vision training to improve objective and subjective visuomotor function in a low-vision patient. A 37-year-old woman with Usher syndrome presented with reduced central visual acuity and visual field. Although we were unable to reverse the damage resulting from her diagnosis, we were able to improve the use of the remaining vision. A 27 to 31% improvement in hand-eye coordination was achieved along with a 41% improvement in object tracking and visual concentration. Most importantly, following the 14-week training period, there was also a subjective improvement in the patient's appreciation of her visual ability. The sports vision literature cites many examples in which sports vision training is useful in improving visuomotor and on-field performance. We hypothesized that these techniques may be used to aid not only athletes but also patients with low vision. Despite suffering from reduced acuity and a limited visual field, these patients often still have a significant amount of vision ability that can be used to guide motor actions. Using techniques to increase the efficient use of this remaining vision may reduce the impact of the reduced visual function and aid in activities of daily living.

  10. 16 CFR 1203.14 - Peripheral vision test.

    Science.gov (United States)

    2010-01-01

    ....14 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS... from each side of the midsagittal plane around the point K (see Figure 6 of this part). Point K is... planes. The vision shall not be obstructed within 105 degrees from point K on each side of the...

  11. Foveal Processing Under Concurrent Peripheral Load in Profoundly Deaf Adults

    Science.gov (United States)

    2016-01-01

    Development of the visual system typically proceeds in concert with the development of audition. One result is that the visual system of profoundly deaf individuals differs from that of those with typical auditory systems. While past research has suggested deaf people have enhanced attention in the visual periphery, it is still unclear whether or not this enhancement entails deficits in central vision. Profoundly deaf and typically hearing adults were administered a variant of the useful field of view task that independently assessed performance on concurrent central and peripheral tasks. Identification of a foveated target was impaired by a concurrent selective peripheral attention task, more so in profoundly deaf adults than in the typically hearing. Previous findings of enhanced performance on the peripheral task were not replicated. These data are discussed in terms of flexible allocation of spatial attention targeted towards perceived task demands, and support a modified “division of labor” hypothesis whereby attentional resources co-opted to process peripheral space result in reduced resources in the central visual field. PMID:26657078

  12. Relationship between functional vision and balance and mobility performance in community-dwelling older adults.

    Science.gov (United States)

    Aartolahti, Eeva; Häkkinen, Arja; Lönnroos, Eija; Kautiainen, Hannu; Sulkava, Raimo; Hartikainen, Sirpa

    2013-10-01

    Vision is an important prerequisite for balance control and mobility. The role of objectively measured visual functions has been previously studied but less is known about associations of functional vision, that refers to self-perceived vision-based ability to perform daily activities. The aim of the study was to investigate the relationship between functional vision and balance and mobility performance in a community-based sample of older adults. This study is part of a Geriatric Multidisciplinary Strategy for the Good Care of the Elderly project (GeMS). Participants (576) aged 76-100 years (mean age 81 years, 70 % women) were interviewed using a seven-item functional vision questionnaire (VF-7). Balance and mobility were measured by the Berg balance scale (BBS), timed up and go (TUG), chair stand test, and maximal walking speed. In addition, self-reported fear of falling, depressive symptoms (15-item Geriatric Depression Scale), cognition (Mini-Mental State Examination) and physical activity (Grimby) were assessed. In the analysis, participants were classified into poor, moderate, or good functional vision groups. The poor functional vision group (n = 95) had more comorbidities, depressed mood, cognition decline, fear of falling, and reduced physical activity compared to participants with moderate (n = 222) or good functional vision (n = 259). Participants with poor functional vision performed worse on all balance and mobility tests. After adjusting for gender, age, chronic conditions, and cognition, the linearity remained statistically significant between functional vision and BBS (p = 0.013), TUG (p = 0.010), and maximal walking speed (p = 0.008), but not between functional vision and chair stand (p = 0.069). Poor functional vision is related to weaker balance and mobility performance in community-dwelling older adults. This highlights the importance of widespread assessment of health, including functional vision, to prevent balance impairment and maintain

  13. Relationship between functional vision and balance and mobility performance in community-dwelling older adults

    OpenAIRE

    Aartolahti, Eeva; Häkkinen, Arja; Lönnroos, Eija; Kautiainen, Hannu; Sulkava, Raimo; Hartikainen, Sirpa

    2013-01-01

    Background and Aims: Vision is an important prerequisite for balance control and mobility. The role of objectively measured visual functions has been previously studied but less is known about associations of functional vision. That refers to selfperceived vision-based ability to perform daily activities. The aim was to investigate the relationship between functional vision and balance and mobility performance in a community-based sample of older adults. Methods: This study ...

  14. The Charles F. Prentice Award Lecture 2010: A Case for Peripheral Optical Treatment Strategies for Myopia

    Science.gov (United States)

    Smith, Earl L.

    2011-01-01

    It is well established that refractive development is regulated by visual feedback. However, most optical treatment strategies designed to reduce myopia progression have not produced the desired results, primarily because some of our assumptions concerning the operating characteristics of the vision-dependent mechanisms that regulate refractive development have been incorrect. In particular, because of the prominence of central vision in primates, it has generally been assumed that signals from the fovea determine the effects of vision on refractive development. However, experiments in laboratory animals demonstrate that ocular growth and emmetropization are mediated by local retinal mechanisms and that foveal vision is not essential for many vision-dependent aspects of refractive development. On the other hand, the peripheral retina, in isolation, can effectively regulate emmetropization and mediate many of the effects of vision on the eye’s refractive status. Moreover, when there are conflicting visual signals between the fovea and the periphery, peripheral vision can dominate refractive development. The overall pattern of results suggests that optical treatment strategies for myopia that take into account the effects of peripheral vision are likely to be more successful than strategies that effectively manipulate only central vision. PMID:21747306

  15. The Level of Vision Necessary for Competitive Performance in Rifle Shooting: Setting the Standards for Paralympic Shooting With Vision Impairment

    Directory of Open Access Journals (Sweden)

    Peter M Allen

    2016-11-01

    Full Text Available The aim of this study was to investigate the level of vision impairment that would reduce performance in shooting; to guide development of entry criteria to visually impaired (VI shooting. Nineteen international-level shooters without vision impairment took part in the study. Participants shot an air rifle, while standing, towards a regulation target placed at the end of a 10m shooting range. Cambridge simulation glasses were used to simulate six different levels of vision impairment. Visual acuity (VA and contrast sensitivity (CS were assessed along with shooting performance in each of seven conditions of simulated impairment and compared to that with habitual vision. Shooting performance was evaluated by calculating each individual’s average score in every level of simulated vision impairment and normalising this score by expressing it as a percentage of the baseline performance achieved with habitual vision. Receiver Operating Characteristic (ROC curves were constructed to evaluate the ability of different VA and CS cut-off criteria to appropriately classify these athletes as achieving ‘expected’ or ‘below expected’ shooting results based on their performance with different levels of VA and CS. Shooting performance remained relatively unaffected by mild decreases in VA and CS, but quickly deteriorated with more moderate losses. The ability of visual function measurements to classify shooting performance was good, with 78% of performances appropriately classified using a cut-off of 0.53 logMAR and 74% appropriately classified using a cut-off of 0.83 logCS. The current inclusion criteria for VI shooting (1.0 logMAR is conservative, maximising the chance of including only those with an impairment that does impact performance, but potentially excluding some who do have a genuine impairment in the sport. A lower level of impairment would include more athletes who do have a genuine impairment but would potentially include those who do not

  16. 78 FR 12815 - Qualification of Drivers; Exemption Applications; Vision

    Science.gov (United States)

    2013-02-25

    .... The best corrected visual acuity in his right eye is light perception, and in his left eye, 20/20.... Lifelong. Stable. Visual fields WNL. Color WNL. No contraindications for commercial driving.'' Mr. Clark... color vision, 180 degrees of peripheral vision, no medical contraindication to commercial truck driving...

  17. Development of VIPER: a simulator for assessing vision performance of warfighters

    Science.gov (United States)

    Familoni, Jide; Thompson, Roger; Moyer, Steve; Mueller, Gregory; Williams, Tim; Nguyen, Hung-Quang; Espinola, Richard L.; Sia, Rose K.; Ryan, Denise S.; Rivers, Bruce A.

    2016-05-01

    Background: When evaluating vision, it is important to assess not just the ability to read letters on a vision chart, but also how well one sees in real life scenarios. As part of the Warfighter Refractive Eye Surgery Program (WRESP), visual outcomes are assessed before and after refractive surgery. A Warfighter's ability to read signs and detect and identify objects is crucial, not only when deployed in a military setting, but also in their civilian lives. Objective: VIPER, a VIsion PERformance simulator was envisioned as actual video-based simulated driving to test warfighters' functional vision under realistic conditions. Designed to use interactive video image controlled environments at daytime, dusk, night, and with thermal imaging vision, it simulates the experience of viewing and identifying road signs and other objects while driving. We hypothesize that VIPER will facilitate efficient and quantifiable assessment of changes in vision and measurement of functional military performance. Study Design: Video images were recorded on an isolated 1.1 mile stretch of road with separate target sets of six simulated road signs and six objects of military interest, separately. The video footage were integrated with customdesigned C++ based software that presented the simulated drive to an observer on a computer monitor at 10, 20 or 30 miles/hour. VIPER permits the observer to indicate when a target is seen and when it is identified. Distances at which the observer recognizes and identifies targets are automatically logged. Errors in recognition and identification are also recorded. This first report describes VIPER's development and a preliminary study to establish a baseline for its performance. In the study, nine soldiers viewed simulations at 10 miles/hour and 30 miles/hour, run in randomized order for each participant seated at 36 inches from the monitor. Relevance: Ultimately, patients are interested in how their vision will affect their ability to perform daily

  18. Using optic flow in the far peripheral field.

    Science.gov (United States)

    McManus, Meaghan; D'Amour, Sarah; Harris, Laurence R

    2017-07-01

    Self-motion information can be used to update spatial memory of location through an estimate of a change in position. Viewing optic flow alone can create Illusory self-motion or "vection." Early studies suggested that peripheral vision is more effective than central vision in evoking vection, but controlling for retinal area and perceived distance suggests that all retinal areas may be equally effective. However, the contributions of the far periphery, beyond 90°, have been largely neglected. Using a large-field Edgeless Graphics Geometry display (EGG, Christie, Canada, field of view ±112°) and systematically blocking central (±20° to ±90°) or peripheral (viewing through tunnels ±20° to ±40°) parts of the field, we compared the effectiveness of different retinal regions at evoking forwards linear vection. Fifteen participants indicated when they had reached the position of a previously presented target after visually simulating motion down a simulated corridor. The amount of simulated travel needed to match a given target distance was modelled with a leaky spatial integrator model to estimate gains (perceived/actual distance) and a spatial decay factor. When optic flow was presented only in the far periphery (beyond 90°) gains were significantly higher than for the same motion presented full field or in only the central field, resulting in accurate performance in the range of speeds associated with normal walking. The increased effectiveness of optic flow in the peripheral field alone compared to full-field motion is discussed in terms of emerging neurophysiological studies that suggest brain areas dedicated to processing information from the far peripheral field.

  19. The role of vision processing in prosthetic vision.

    Science.gov (United States)

    Barnes, Nick; He, Xuming; McCarthy, Chris; Horne, Lachlan; Kim, Junae; Scott, Adele; Lieby, Paulette

    2012-01-01

    Prosthetic vision provides vision which is reduced in resolution and dynamic range compared to normal human vision. This comes about both due to residual damage to the visual system from the condition that caused vision loss, and due to limitations of current technology. However, even with limitations, prosthetic vision may still be able to support functional performance which is sufficient for tasks which are key to restoring independent living and quality of life. Here vision processing can play a key role, ensuring that information which is critical to the performance of key tasks is available within the capability of the available prosthetic vision. In this paper, we frame vision processing for prosthetic vision, highlight some key areas which present problems in terms of quality of life, and present examples where vision processing can help achieve better outcomes.

  20. In-Vision Continuity Announcers: Performing an Identity for Early Television in Europe

    Directory of Open Access Journals (Sweden)

    Sonja de Leeuw

    2013-12-01

    Full Text Available In-vision continuity announcers have played central – yet understudied – roles in early television history. Through their performances on and off the screen, they mediated the identity of the televisual medium in the 1950s and 1960s, popularizing it as a medium of sound and vision, a domestic and gendered medium as well as a national and transnational institution.Focusing primarily on Dutch and Romanian female in-vision continuity announcers in the 1950s and 60s and making extensive comparisons with other countries in Europe, this article illustrates how these early professionals of television performed as part of a European-wide phenomenon of defining the identity of the new televisual medium.

  1. Driving and Low Vision: Validity of Assessments for Predicting Performance of Drivers

    Science.gov (United States)

    Strong, J. Graham; Jutai, Jeffrey W.; Russell-Minda, Elizabeth; Evans, Mal

    2008-01-01

    The authors conducted a systematic review to examine whether vision-related assessments can predict the driving performance of individuals who have low vision. The results indicate that measures of visual field, contrast sensitivity, cognitive and attention-based tests, and driver screening tools have variable utility for predicting real-world…

  2. Relationship between upper extremity kinesthetic sense and writing performance by students with low vision.

    Science.gov (United States)

    Aki, Esra; Atasavun, Songül; Kayihan, Holya

    2008-06-01

    Kinesthetic sense plays an important role in writing. Children with low vision lack sensory input from the environment given their loss of vision. This study assessed the effect of upper extremity kinesthetic sense on writing function in two groups, one of students with low vision (9 girls and 11 boys, 9.4 +/- 1.9 yr. of age) and one of sighted students (10 girls and 10 boys, 10.1 +/- 1.3 yr. of age). All participants were given the Kinesthesia Test and Jebsen Hand Function Test-Writing subtest. Students with low vision scored lower on kinesthetic perception and writing performance than sighted peers. The correlation between scores for writing performance and upper extremity kinesthetic sense in the two groups was significant (r = -.34). The probability of deficiencies in kinesthetic information in students with low vision must be remembered.

  3. Performance characterization of night vision equipment based on Triangle Orientation Discrimination (TOD) methodology

    NARCIS (Netherlands)

    Laurent, N.; Lejard, C.; Deltel, G.; Bijl, P.

    2013-01-01

    Night vision equipment is crucial in order to accomplish supremacy and safety of the troops on the battlefield. Evidently, system integrators, MODs and end-users need access to reliable quantitative characterization of the expected field performance when using night vision equipment. The Image

  4. Vision Lab

    Data.gov (United States)

    Federal Laboratory Consortium — The Vision Lab personnel perform research, development, testing and evaluation of eye protection and vision performance. The lab maintains and continues to develop...

  5. Central and Peripheral Vision Loss Differentially Affects Contextual Cueing in Visual Search

    Science.gov (United States)

    Geringswald, Franziska; Pollmann, Stefan

    2015-01-01

    Visual search for targets in repeated displays is more efficient than search for the same targets in random distractor layouts. Previous work has shown that this contextual cueing is severely impaired under central vision loss. Here, we investigated whether central vision loss, simulated with gaze-contingent displays, prevents the incidental…

  6. Low Vision FAQs

    Science.gov (United States)

    ... de los Ojos Cómo hablarle a su oculista Low Vision FAQs What is low vision? Low vision is a visual impairment, not correctable ... person’s ability to perform everyday activities. What causes low vision? Low vision can result from a variety of ...

  7. Impact of 3D vision on mental workload and laparoscopic performance in inexperienced subjects.

    Science.gov (United States)

    Gómez-Gómez, E; Carrasco-Valiente, J; Valero-Rosa, J; Campos-Hernández, J P; Anglada-Curado, F J; Carazo-Carazo, J L; Font-Ugalde, P; Requena-Tapia, M J

    2015-05-01

    To assess the effect of vision in three dimensions (3D) versus two dimensions (2D) on mental workload and laparoscopic performance during simulation-based training. A prospective, randomized crossover study on inexperienced students in operative laparoscopy was conducted. Forty-six candidates executed five standardized exercises on a pelvitrainer with both vision systems (3D and 2D). Laparoscopy performance was assessed using the total time (in seconds) and the number of failed attempts. For workload assessment, the validated NASA-TLX questionnaire was administered. 3D vision improves the performance reducing the time (3D = 1006.08 ± 315.94 vs. 2D = 1309.17 ± 300.28; P NASA-TLX results, less mental workload is experienced with the use of 3D (P < .001). However, 3D vision was associated with greater visual impairment (P < .01) and headaches (P < .05). The incorporation of 3D systems in laparoscopic training programs would facilitate the acquisition of laparoscopic skills, because they reduce mental workload and improve the performance on inexperienced surgeons. However, some undesirable effects such as visual discomfort or headache are identified initially. Copyright © 2014 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. Visual Search Performance in Patients with Vision Impairment: A Systematic Review.

    Science.gov (United States)

    Senger, Cassia; Margarido, Maria Rita Rodrigues Alves; De Moraes, Carlos Gustavo; De Fendi, Ligia Issa; Messias, André; Paula, Jayter Silva

    2017-11-01

    Patients with visual impairment are constantly facing challenges to achieve an independent and productive life, which depends upon both a good visual discrimination and search capacities. Given that visual search is a critical skill for several daily tasks and could be used as an index of the overall visual function, we investigated the relationship between vision impairment and visual search performance. A comprehensive search was undertaken using electronic PubMed, EMBASE, LILACS, and Cochrane databases from January 1980 to December 2016, applying the following terms: "visual search", "visual search performance", "visual impairment", "visual exploration", "visual field", "hemianopia", "search time", "vision lost", "visual loss", and "low vision". Two hundred seventy six studies from 12,059 electronic database files were selected, and 40 of them were included in this review. Studies included participants of all ages, both sexes, and the sample sizes ranged from 5 to 199 participants. Visual impairment was associated with worse visual search performance in several ophthalmologic conditions, which were either artificially induced, or related to specific eye and neurological diseases. This systematic review details all the described circumstances interfering with visual search tasks, highlights the need for developing technical standards, and outlines patterns for diagnosis and therapy using visual search capabilities.

  9. Towards OpenVL: Improving Real-Time Performance of Computer Vision Applications

    Science.gov (United States)

    Shen, Changsong; Little, James J.; Fels, Sidney

    Meeting constraints for real-time performance is a main issue for computer vision, especially for embedded computer vision systems. This chapter presents our progress on our open vision library (OpenVL), a novel software architecture to address efficiency through facilitating hardware acceleration, reusability, and scalability for computer vision systems. A logical image understanding pipeline is introduced to allow parallel processing. We also discuss progress on our middleware—vision library utility toolkit (VLUT)—that enables applications to operate transparently over a heterogeneous collection of hardware implementations. OpenVL works as a state machine,with an event-driven mechanismto provide users with application-level interaction. Various explicit or implicit synchronization and communication methods are supported among distributed processes in the logical pipelines. The intent of OpenVL is to allow users to quickly and easily recover useful information from multiple scenes, in a cross-platform, cross-language manner across various software environments and hardware platforms. To validate the critical underlying concepts of OpenVL, a human tracking system and a local positioning system are implemented and described. The novel architecture separates the specification of algorithmic details from the underlying implementation, allowing for different components to be implemented on an embedded system without recompiling code.

  10. Sneaking a peek: pigeons use peripheral vision (not mirrors) to find hidden food.

    Science.gov (United States)

    Ünver, Emre; Garland, Alexis; Tabrik, Sepideh; Güntürkün, Onur

    2017-07-01

    A small number of species are capable of recognizing themselves in the mirror when tested with the mark-and-mirror test. This ability is often seen as evidence of self-recognition and possibly even self-awareness. Strangely, a number of species, for example monkeys, pigs and dogs, are unable to pass the mark test but can locate rewarding objects by using the reflective properties of a mirror. Thus, these species seem to understand how a visual reflection functions but cannot apply it to their own image. We tested this discrepancy in pigeons-a species that does not spontaneously pass the mark test. Indeed, we discovered that pigeons can successfully find a hidden food reward using only the reflection, suggesting that pigeons can also use and potentially understand the reflective properties of mirrors, even in the absence of self-recognition. However, tested under monocular conditions, the pigeons approached and attempted to walk through the mirror rather than approach the physical food, displaying similar behavior to patients with mirror agnosia. These findings clearly show that pigeons do not use the reflection of mirrors to locate reward, but actually see the food peripherally with their near-panoramic vision. A re-evaluation of our current understanding of mirror-mediated behavior might be necessary-especially taking more fully into account species differences in visual field. This study suggests that use of reflections in a mirrored surface as a tool may be less widespread than currently thought.

  11. The risk of pedestrian collisions with peripheral visual field loss

    OpenAIRE

    Peli, Eli; Apfelbaum, Henry; Berson, Eliot L.; Goldstein, Robert B.

    2016-01-01

    Patients with peripheral field loss complain of colliding with other pedestrians in open-space environments such as shopping malls. Field expansion devices (e.g., prisms) can create artificial peripheral islands of vision. We investigated the visual angle at which these islands can be most effective for avoiding pedestrian collisions, by modeling the collision risk density as a function of bearing angle of pedestrians relative to the patient. Pedestrians at all possible locations were assumed...

  12. The Level of Vision Necessary for Competitive Performance in Rifle Shooting: Setting the Standards for Paralympic Shooting with Vision Impairment.

    Science.gov (United States)

    Allen, Peter M; Latham, Keziah; Mann, David L; Ravensbergen, Rianne H J C; Myint, Joy

    2016-01-01

    The aim of this study was to investigate the level of vision impairment (VI) that would reduce performance in shooting; to guide development of entry criteria to visually impaired (VI) shooting. Nineteen international-level shooters without VI took part in the study. Participants shot an air rifle, while standing, toward a regulation target placed at the end of a 10 m shooting range. Cambridge simulation glasses were used to simulate six different levels of VI. Visual acuity (VA) and contrast sensitivity (CS) were assessed along with shooting performance in each of seven conditions of simulated impairment and compared to that with habitual vision. Shooting performance was evaluated by calculating each individual's average score in every level of simulated VI and normalizing this score by expressing it as a percentage of the baseline performance achieved with habitual vision. Receiver Operating Characteristic curves were constructed to evaluate the ability of different VA and CS cut-off criteria to appropriately classify these athletes as achieving 'expected' or 'below expected' shooting results based on their performance with different levels of VA and CS. Shooting performance remained relatively unaffected by mild decreases in VA and CS, but quickly deteriorated with more moderate losses. The ability of visual function measurements to classify shooting performance was good, with 78% of performances appropriately classified using a cut-off of 0.53 logMAR and 74% appropriately classified using a cut-off of 0.83 logCS. The current inclusion criteria for VI shooting (1.0 logMAR) is conservative, maximizing the chance of including only those with an impairment that does impact performance, but potentially excluding some who do have a genuine impairment in the sport. A lower level of impairment would include more athletes who do have a genuine impairment but would potentially include those who do not actually have an impairment that impacts performance in the sport. An

  13. Effects of visual skills training, vision coaching and sports vision ...

    African Journals Online (AJOL)

    The purpose of this study was to determine the effectiveness of three different approaches to improving sports performance through improvements in “sports vision:” (1) a visual skills training programme, (2) traditional vision coaching sessions, and (3) a multi-disciplinary approach identified as sports vision dynamics.

  14. Vision Related Quality of Life in Patients with Keratoconus

    Directory of Open Access Journals (Sweden)

    Sevda Aydin Kurna

    2014-01-01

    Full Text Available Purpose. The purpose of this study is to evaluate the vision related quality of life in patients with keratoconus by using the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25. Methods. Thirty patients presented with keratoconus (keratoconus group and 30 healthy patients (control group were included in this study. Twenty patients were using rigid gas permeable and 10 patients were not using contact lenses in keratoconus group. High and low contrast visual acuity and mean K values of the patients were recorded. Each subject completed the 25-item NEI-VFQ-25. Results. All subscales of NEI-VFQ-25 were lower in the keratoconus patients. The difference was more evident in the subscales of general vision, ocular pain, near vision, vision-specific mental health, vision-specific role difficulties, and peripheral vision P 0.4 in the better eye had lower distance vision, social functioning, mental health, and role difficulties. Meanwhile, patients with low visual acuity (logMAR > 0.4 in the worse eye had lower general health scores P<0.05. Conclusions. Vision related quality of life was worse in keratoconus patients. Success in the contact lens usage and maintaining higher visual acuity may improve vision related quality of life.

  15. Influence of anaerobic physical effort in the horizontal and vertical peripheral view INFLUENCIA DEL ESFUERZO FÍSICO ANAERÓBICO EN LA VISIÓN PERIFÉRICA VERTICAL Y HORIZONTAL

    Directory of Open Access Journals (Sweden)

    M. Arteaga

    2010-09-01

    Full Text Available

    There now seems to be a generalized tendency to consider that sporting performance declines as the sportsperson becomes fatigued. However, there is little empirical evidence to show that this adversely affects visual function. In some sports it is necessary to see stimuli in zones peripheral to central vision. The aim of this study is to analyze the influence of anaerobic exertion on vertical and horizontal Peripheral Vision. An intra-subject design was used with 14 replications. The visual parameters of Vertical Peripheral Vision and Horizontal Peripheral Vision were measured in different fatigue conditions to analyze the possible negative influence which this could exert on the subject’s visual capacity. The results show that fatigue due to anaerobic effort does not harm the visual abilities studied.
    KEY WORDS: Peripheral Vision, Fatigue, Anaerobic exertion, Visual abilities

    Parece haber una tendencia generalizada a considerar que el rendimiento deportivo disminuye en la medida en que los deportistas acumulan fatiga; sin embargo existen pocas evidencias empíricas que indiquen que la función visual se vea perjudicada por este motivo. En algunos deportes es necesario observar estímulos en zonas periféricas a la visión central. En el presente estudio se pretende analizar la influencia de los esfuerzos anaeeróbicos sobre la Visión Periférica (vertical y horizontal. Se utilizó un diseño intrasujeto A-(B1,B2-A con catorce replicaciones. Se realizaron mediciones de los parámetros visuales: Visión Periférica Vertical y Visión Periférica Horizontal en diferentes condiciones de fatiga para analizar la posible influencia negativa que pudiera ejercer ésta sobre la capacidad visual de los sujetos. Los resultados permiten afirmar que la fatiga debida a esfuerzos de tipo anaeróbico no producen un perjuicio sobre las habilidades visuales estudiadas.
    PALABRAS CLAVE: Visi

  16. Visual function and color vision in adults with Attention-Deficit/Hyperactivity Disorder.

    Science.gov (United States)

    Kim, Soyeon; Chen, Samantha; Tannock, Rosemary

    2014-01-01

    Color vision and self-reported visual function in everyday life in young adults with Attention-Deficit/Hyperactivity Disorder (ADHD) were investigated. Participants were 30 young adults with ADHD and 30 controls matched for age and gender. They were tested individually and completed the Visual Activities Questionnaire (VAQ), Farnsworth-Munsell 100 Hue Test (FMT) and A Quick Test of Cognitive Speed (AQT). The ADHD group reported significantly more problems in 4 of 8 areas on the VAQ: depth perception, peripheral vision, visual search and visual processing speed. Further analyses of VAQ items revealed that the ADHD group endorsed more visual problems associated with driving than controls. Color perception difficulties on the FMT were restricted to the blue spectrum in the ADHD group. FMT and AQT results revealed slower processing of visual stimuli in the ADHD group. A comprehensive investigation of mechanisms underlying visual function and color vision in adults with ADHD is warranted, along with the potential impact of these visual problems on driving performance. Copyright © 2013 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  17. Differential GNSS and Vision-Based Tracking to Improve Navigation Performance in Cooperative Multi-UAV Systems

    Directory of Open Access Journals (Sweden)

    Amedeo Rodi Vetrella

    2016-12-01

    Full Text Available Autonomous navigation of micro-UAVs is typically based on the integration of low cost Global Navigation Satellite System (GNSS receivers and Micro-Electro-Mechanical Systems (MEMS-based inertial and magnetic sensors to stabilize and control the flight. The resulting navigation performance in terms of position and attitude accuracy may not suffice for other mission needs, such as the ones relevant to fine sensor pointing. In this framework, this paper presents a cooperative UAV navigation algorithm that allows a chief vehicle, equipped with inertial and magnetic sensors, a Global Positioning System (GPS receiver, and a vision system, to improve its navigation performance (in real time or in the post processing phase exploiting formation flying deputy vehicles equipped with GPS receivers. The focus is set on outdoor environments and the key concept is to exploit differential GPS among vehicles and vision-based tracking (DGPS/Vision to build a virtual additional navigation sensor whose information is then integrated in a sensor fusion algorithm based on an Extended Kalman Filter. The developed concept and processing architecture are described, with a focus on DGPS/Vision attitude determination algorithm. Performance assessment is carried out on the basis of both numerical simulations and flight tests. In the latter ones, navigation estimates derived from the DGPS/Vision approach are compared with those provided by the onboard autopilot system of a customized quadrotor. The analysis shows the potential of the developed approach, mainly deriving from the possibility to exploit magnetic- and inertial-independent accurate attitude information.

  18. Case of Unilateral Peripheral Cone Dysfunction

    Directory of Open Access Journals (Sweden)

    Yujin Mochizuki

    2012-05-01

    Full Text Available Purpose: Peripheral cone dystrophy is a subgroup of cone dystrophy, and only 4 cases have been reported. We present a patient with unilateral peripheral cone dysfunction and report the functional changes determined by electrophysiological tests and ultrastructural changes determined by spectral domain optical coherence tomography (SD-OCT. Case: A 34-year-old woman complained of blurred vision in both eyes. Our examination showed that her visual acuity was 0.05 OD and 0.2 OS. A relative afferent pupillary defect was present in her right eye. The results of slit-lamp examination, ophthalmoscopy, and fluorescein angiography were normal except for pallor of the right optic disc. SD-OCT showed a diffuse thinning of the retina in the posterior pole of the right eye. A severe constriction of the visual fields was found in both eyes but more in the right eye. The photopic full-field electroretinograms (ERGs were reduced in the right eye but normal in the left eye. The multifocal ERGs were severely reduced throughout the visual field except in the central area of the right eye. The multifocal ERGs from the left eye were normal. The pattern visual evoked responses were within the normal range in both eyes. She had a 5-year history of sniffing paint thinner. Results: Although the visual dysfunction was initially suspected to be due to psychological problems from the results of subjective tests, objective tests indicated a peripheral cone dysfunction in the right eye. The pathophysiological mechanism and the relationship with thinner sniffing were not determined. Conclusions: Our findings indicate that peripheral cone dysfunction can occur unilaterally. Electrophysiology and SD-OCT are valuable tests to perform to determine the pathogenesis of unusual ocular findings objectively.

  19. Performance evaluation of 3D vision-based semi-autonomous control method for assistive robotic manipulator.

    Science.gov (United States)

    Ka, Hyun W; Chung, Cheng-Shiu; Ding, Dan; James, Khara; Cooper, Rory

    2018-02-01

    We developed a 3D vision-based semi-autonomous control interface for assistive robotic manipulators. It was implemented based on one of the most popular commercially available assistive robotic manipulator combined with a low-cost depth-sensing camera mounted on the robot base. To perform a manipulation task with the 3D vision-based semi-autonomous control interface, a user starts operating with a manual control method available to him/her. When detecting objects within a set range, the control interface automatically stops the robot, and provides the user with possible manipulation options through audible text output, based on the detected object characteristics. Then, the system waits until the user states a voice command. Once the user command is given, the control interface drives the robot autonomously until the given command is completed. In the empirical evaluations conducted with human subjects from two different groups, it was shown that the semi-autonomous control can be used as an alternative control method to enable individuals with impaired motor control to more efficiently operate the robot arms by facilitating their fine motion control. The advantage of semi-autonomous control was not so obvious for the simple tasks. But, for the relatively complex real-life tasks, the 3D vision-based semi-autonomous control showed significantly faster performance. Implications for Rehabilitation A 3D vision-based semi-autonomous control interface will improve clinical practice by providing an alternative control method that is less demanding physically as well cognitively. A 3D vision-based semi-autonomous control provides the user with task specific intelligent semiautonomous manipulation assistances. A 3D vision-based semi-autonomous control gives the user the feeling that he or she is still in control at any moment. A 3D vision-based semi-autonomous control is compatible with different types of new and existing manual control methods for ARMs.

  20. The Level of Vision Necessary for Competitive Performance in Rifle Shooting: Setting the Standards for Paralympic Shooting with Vision Impairment

    NARCIS (Netherlands)

    Allen, P.M.; Latham, K.; Mann, D.L.; Ravensbergen, H.J.C.; Myint, J.

    2016-01-01

    The aim of this study was to investigate the level of vision impairment (VI) that would reduce performance in shooting; to guide development of entry criteria to visually impaired (VI) shooting. Nineteen international-level shooters without VI took part in the study. Participants shot an air rifle,

  1. Landing performance by low-time private pilots after the sudden loss of binocular vision - Cyclops II

    Science.gov (United States)

    Lewis, C. E., Jr.; Swaroop, R.; Mcmurty, T. C.; Blakeley, W. R.; Masters, R. L.

    1973-01-01

    Study of low-time general aviation pilots, who, in a series of spot landings, were suddenly deprived of binocular vision by patching either eye on the downwind leg of a standard, closed traffic pattern. Data collected during these landings were compared with control data from landings flown with normal vision during the same flight. The sequence of patching and the mix of control and monocular landings were randomized to minimize the effect of learning. No decrease in performance was observed during landings with vision restricted to one eye, in fact, performance improved. This observation is reported at a high level of confidence (p less than 0.001). These findings confirm the previous work of Lewis and Krier and have important implications with regard to aeromedical certification standards.

  2. Performance of Color Camera Machine Vision in Automated Furniture Rough Mill Systems

    Science.gov (United States)

    D. Earl Kline; Agus Widoyoko; Janice K. Wiedenbeck; Philip A. Araman

    1998-01-01

    The objective of this study was to evaluate the performance of color camera machine vision for lumber processing in a furniture rough mill. The study used 134 red oak boards to compare the performance of automated gang-rip-first rough mill yield based on a prototype color camera lumber inspection system developed at Virginia Tech with both estimated optimum rough mill...

  3. GPS Usage in a Population of Low-Vision Drivers.

    Science.gov (United States)

    Cucuras, Maria; Chun, Robert; Lee, Patrick; Jay, Walter M; Pusateri, Gregg

    2017-01-01

    We surveyed bioptic and non-bioptic low-vision drivers in Illinois, USA, to determine their usage of global positioning system (GPS) devices. Low-vision patients completed an IRB-approved phone survey regarding driving demographics and usage of GPS while driving. Participants were required to be active drivers with an Illinois driver's license, and met one of the following criteria: best-corrected visual acuity (BCVA) less than or equal to 20/40, central or significant peripheral visual field defects, or a combination of both. Of 27 low-vision drivers, 10 (37%) used GPS while driving. The average age for GPS users was 54.3 and for non-users was 77.6. All 10 drivers who used GPS while driving reported increased comfort or safety level. Since non-GPS users were significantly older than GPS users, it is likely that older participants would benefit from GPS technology training from their low-vision eye care professionals.

  4. Comparing the relative peripheral refraction effect of single vision and multifocal contact lenses measured using an autorefractor and an aberrometer: A pilot study.

    Science.gov (United States)

    Bakaraju, Ravi C; Fedtke, Cathleen; Ehrmann, Klaus; Ho, Arthur

    2015-01-01

    To compare the contributions of single vision (SVCL) and multifocal contact lenses (MFCL) to the relative peripheral refraction (RPR) profiles obtained via an autorefractor and an aberrometer in a pilot study. Two instruments, Shin-Nippon NVision K5001 (SN) and COAS-HD, were modified to permit open field PR measurements. Two myopic adults (CF, RB) were refracted (cycloplegia) under eight conditions: baseline (no CL); three SVCLs: Focus Dailies(®) (Alcon, USA), PureVision(®) (Bausch & Lomb, USA) and AirOptix(®) (Alcon, USA); and four MFCLs: AirOptix(®) (Alcon, USA), Proclear(®) Distant and Near (Cooper Vision, USA), and PureVision(®) (Bausch & Lomb, USA). CLs had a distance prescription of -2.00D and for MFCLs, a +2.50D Add was selected. Five independent measurements were performed at field angles from -40° to +40° in 10° increments with both instruments. The COAS-HD measures were analyzed at 3mm pupil diameter. Results are reported as a change in the relative PR profile, as refractive power vector components: M, J180, and J45. Overall, at baseline, M, J180 and J45 measures obtained with SN and COAS-HD were considerably different only for field angles ≥±30°, which agreed well with previous studies. With respect to M, this observation held true for most SVCLs with a few exceptions. The J180 measures obtained with COAS-HD were considerably greater in magnitude than those acquired with SN. For SVCLs, the greatest difference was found at -40° for AirOptix SV (ΔCF=3.20D, ΔRB=1.56D) and for MFCLs it was for Proclear Distance at -40° (ΔCF=2.58D, ΔRB=1.39D). The J45 measures obtained with SN were noticeably different to the respective measures with COAS-HD, both in magnitude and sign. The greatest difference was found with AirOptix Multifocal in subject RB at -40°, where the COAS-HD measurement was 1.50D more positive. In some cases, the difference in the RPR profiles observed between subjects appeared to be associated with CL decentration. For most test

  5. Vision related quality of life in patients with type 2 diabetes in the EUROCONDOR trial.

    Science.gov (United States)

    Trento, Marina; Durando, Olga; Lavecchia, Sonia; Charrier, Lorena; Cavallo, Franco; Costa, Miguel Angelo; Hernández, Cristina; Simó, Rafael; Porta, Massimo

    2017-07-01

    To evaluate vision related quality of life in the patients enrolled in The European Consortium for the Early Treatment of Diabetic Retinopathy, a clinical trial on prevention of diabetic retinopathy. Four-hundred-forty-nine patients, 153 women, with type 2 Diabetes and no or mild diabetic retinopathy were enrolled in a 2-year multicenter randomized controlled trial. The 25-item National Eye Institute Visual Functioning Questionnaire was used to explore 12 subscales of vision related quality of life. The patients were 62.8 ± 6.7 years old and had 11.1 ± 5.6 years known disease duration. Diabetic retinopathy was absent in 193 (43.0 %) and mild in 256 (57.0 %). Patients without diabetic retinopathy were older, had shorter diabetes duration and used less insulin and glucose-lowering agents but did not differ by gender, best corrected visual acuity or any subscale, except vision specific mental health and vision specific role difficulties. Patients with reduced retinal thickness at the ganglion cell layer (n = 36) did not differ for diabetic retinopathy but were older, had lower best corrected visual acuity and worse scores for ocular pain, color vision and peripheral vision. On multivariable analysis, worse scores for general vision remained associated with reduced retinal thickness, diabetes duration and best corrected visual acuity, and scores for visual specific mental health with diabetic retinopathy and lower best corrected visual acuity. Visual specific role difficulties were only associated with reduced best corrected visual acuity. Scores for driving decreased among females, with worsening of Hemoglobin A1c and best corrected visual acuity. Color vision depended only on reduced retinal thickness, and peripheral vision on both reduced thickness and best corrected visual acuity. The National Eye Institute Visual Functioning Questionnaire could detect subtle changes in patients' perception of visual function, despite absent/minimal diabetic

  6. A Review: E. Peeren, H. Stuit, A. Van Weyenberg (eds., "Peripheral Visions in The Globalizing Present, Space, Mobility, Aesthetics" (Leide, Boston: Brill, 2016

    Directory of Open Access Journals (Sweden)

    Elia Zaru

    2016-12-01

    Full Text Available In 1980 Gilles Deleuze and Félix Guattari published Mille Plateaux, in which they theorized the philosophical concept of the “rhizome”. With such a notion, the two scholars aimed at breaking any hierarchical ontology. Instead of assuming a situated and territorialized point of view, they argued, the “rhizome” specifically allows the deterritorialization of being, and offers a peripheral vision of the world by excluding the existence of a defined centre. The “rhizome” contrasts what the two authors called an “arborescent” conception of knowledge, characterized by a precise hierarchic form. While in the former every point is necessarily related to each single other, the latter functions exactly by fixing a set of principal points which follow an exclusion principle. The “arborescent” scheme proceeds through dichotomy and hierarchy, and prevents the undesirable connections.

  7. The expected performance of local energy visions in Europe : A governance perspective

    NARCIS (Netherlands)

    Van Bueren, E.M.; Dignum, M.; Steenhuisen, B.M.

    2015-01-01

    This paper offers insights into the expected performance of Sustainable Energy Action Plans (SEAPs) as a policy instrument, a local energy vision initiated by the EU and used by municipalities across Europe. How are SEAPs aiming to contribute to the process of local energy transition and how can

  8. 3D Vision Provides Shorter Operative Time and More Accurate Intraoperative Surgical Performance in Laparoscopic Hiatal Hernia Repair Compared With 2D Vision.

    Science.gov (United States)

    Leon, Piera; Rivellini, Roberta; Giudici, Fabiola; Sciuto, Antonio; Pirozzi, Felice; Corcione, Francesco

    2017-04-01

    The aim of this study is to evaluate if 3-dimensional high-definition (3D) vision in laparoscopy can prompt advantages over conventional 2D high-definition vision in hiatal hernia (HH) repair. Between September 2012 and September 2015, we randomized 36 patients affected by symptomatic HH to undergo surgery; 17 patients underwent 2D laparoscopic HH repair, whereas 19 patients underwent the same operation in 3D vision. No conversion to open surgery occurred. Overall operative time was significantly reduced in the 3D laparoscopic group compared with the 2D one (69.9 vs 90.1 minutes, P = .006). Operative time to perform laparoscopic crura closure did not differ significantly between the 2 groups. We observed a tendency to a faster crura closure in the 3D group in the subgroup of patients with mesh positioning (7.5 vs 8.9 minutes, P = .09). Nissen fundoplication was faster in the 3D group without mesh positioning ( P = .07). 3D vision in laparoscopic HH repair helps surgeon's visualization and seems to lead to operative time reduction. Advantages can result from the enhanced spatial perception of narrow spaces. Less operative time and more accurate surgery translate to benefit for patients and cost savings, compensating the high costs of the 3D technology. However, more data from larger series are needed to firmly assess the advantages of 3D over 2D vision in laparoscopic HH repair.

  9. A compact CCD-monitored atomic force microscope with optical vision and improved performances.

    Science.gov (United States)

    Mingyue, Liu; Haijun, Zhang; Dongxian, Zhang

    2013-09-01

    A novel CCD-monitored atomic force microscope (AFM) with optical vision and improved performances has been developed. Compact optical paths are specifically devised for both tip-sample microscopic monitoring and cantilever's deflection detecting with minimized volume and optimal light-amplifying ratio. The ingeniously designed AFM probe with such optical paths enables quick and safe tip-sample approaching, convenient and effective tip-sample positioning, and high quality image scanning. An image stitching method is also developed to build a wider-range AFM image under monitoring. Experiments show that this AFM system can offer real-time optical vision for tip-sample monitoring with wide visual field and/or high lateral optical resolution by simply switching the objective; meanwhile, it has the elegant performances of nanometer resolution, high stability, and high scan speed. Furthermore, it is capable of conducting wider-range image measurement while keeping nanometer resolution. Copyright © 2013 Wiley Periodicals, Inc.

  10. Evaluation of a Portable Collision Warning Device for Patients With Peripheral Vision Loss in an Obstacle Course.

    Science.gov (United States)

    Pundlik, Shrinivas; Tomasi, Matteo; Luo, Gang

    2015-04-01

    A pocket-sized collision warning device equipped with a video camera was developed to predict impending collisions based on time to collision rather than proximity. A study was conducted in a high-density obstacle course to evaluate the effect of the device on collision avoidance in people with peripheral field loss (PFL). The 41-meter-long loop-shaped obstacle course consisted of 46 stationary obstacles from floor to head level and oncoming pedestrians. Twenty-five patients with tunnel vision (n = 13) or hemianopia (n = 12) completed four consecutive loops with and without the device, while not using any other habitual mobility aid. Walking direction and device usage order were counterbalanced. Number of collisions and preferred percentage of walking speed (PPWS) were compared within subjects. Collisions were reduced significantly by approximately 37% (P < 0.001) with the device (floor-level obstacles were excluded because the device was not designed for them). No patient had more collisions when using the device. Although the PPWS were also reduced with the device from 52% to 49% (P = 0.053), this did not account for the lower number of collisions, as the changes in collisions and PPWS were not correlated (P = 0.516). The device may help patients with a wide range of PFL avoid collisions with high-level obstacles while barely affecting their walking speed.

  11. Emotional facial expression detection in the peripheral visual field.

    Directory of Open Access Journals (Sweden)

    Dimitri J Bayle

    Full Text Available BACKGROUND: In everyday life, signals of danger, such as aversive facial expressions, usually appear in the peripheral visual field. Although facial expression processing in central vision has been extensively studied, this processing in peripheral vision has been poorly studied. METHODOLOGY/PRINCIPAL FINDINGS: Using behavioral measures, we explored the human ability to detect fear and disgust vs. neutral expressions and compared it to the ability to discriminate between genders at eccentricities up to 40°. Responses were faster for the detection of emotion compared to gender. Emotion was detected from fearful faces up to 40° of eccentricity. CONCLUSIONS: Our results demonstrate the human ability to detect facial expressions presented in the far periphery up to 40° of eccentricity. The increasing advantage of emotion compared to gender processing with increasing eccentricity might reflect a major implication of the magnocellular visual pathway in facial expression processing. This advantage may suggest that emotion detection, relative to gender identification, is less impacted by visual acuity and within-face crowding in the periphery. These results are consistent with specific and automatic processing of danger-related information, which may drive attention to those messages and allow for a fast behavioral reaction.

  12. Image enhancement filters significantly improve reading performance for low vision observers

    Science.gov (United States)

    Lawton, T. B.

    1992-01-01

    As people age, so do their photoreceptors; many photoreceptors in central vision stop functioning when a person reaches their late sixties or early seventies. Low vision observers with losses in central vision, those with age-related maculopathies, were studied. Low vision observers no longer see high spatial frequencies, being unable to resolve fine edge detail. We developed image enhancement filters to compensate for the low vision observer's losses in contrast sensitivity to intermediate and high spatial frequencies. The filters work by boosting the amplitude of the less visible intermediate spatial frequencies. The lower spatial frequencies. These image enhancement filters not only reduce the magnification needed for reading by up to 70 percent, but they also increase the observer's reading speed by 2-4 times. A summary of this research is presented.

  13. Comparing sports vision among three groups of soft tennis adolescent athletes: Normal vision, refractive errors with and without correction

    Directory of Open Access Journals (Sweden)

    Shih-Tsun Chang

    2015-01-01

    Full Text Available Background: The effect of correcting static vision on sports vision is still not clear. Aim: To examine whether sports vision (depth perception [DP], dynamic visual acuity [DVA], eye movement [EM], peripheral vision [PV], and momentary vision [MV], were different among soft tennis adolescent athletes with normal vision (Group A, with refractive error and corrected with (Group B and without eyeglasses (Group C. Setting and Design: A cross-section study was conducted. Soft tennis athletes aged 10–13 who played softball tennis for 2–5 years, and who were without any ocular diseases and without visual training for the past 3 months were recruited. Materials and Methods: DPs were measured in an absolute deviation (mm between a moving rod and fixing rod (approaching at 25 mm/s, receding at 25 mm/s, approaching at 50 mm/s, receding at 50 mm/s using electric DP tester. A smaller deviation represented better DP. DVA, EM, PV, and MV were measured on a scale from 1 (worse to 10 (best using ATHLEVISION software. Statistical Analysis: Chi-square test and Kruskal–Wallis test was used to compare the data among the three study groups. Results: A total of 73 athletes (37 in Group A, 8 in Group B, 28 in Group C were enrolled in this study. All four items of DP showed significant difference among the three study groups (P = 0.0051, 0.0004, 0.0095, 0.0021. PV displayed significant difference among the three study groups (P = 0.0044. There was no significant difference in DVA, EM, and MV among the three study groups. Conclusions: Significant better DP and PV were seen among soft tennis adolescent athletes with normal vision than those with refractive error regardless whether they had eyeglasses corrected. On the other hand, DVA, EM, and MV were similar among the three study groups.

  14. Postural Control and Gait Performance in the Diabetic Peripheral Neuropathy: A Systematic Review.

    Science.gov (United States)

    Mustapa, Amirah; Justine, Maria; Mohd Mustafah, Nadia; Jamil, Nursuriati; Manaf, Haidzir

    2016-01-01

    Purpose. The aim of this paper is to review the published studies on the characteristics of impairments in the postural control and gait performance in diabetic peripheral neuropathy (DPN). Methods. A review was performed by obtaining publication of all papers reporting on the postural control and gait performance in DPN from Google Scholar, Ovid, SAGE, Springerlink, Science Direct (SD), EBSCO Discovery Service, and Web of Science databases. The keywords used for searching were "postural control," "balance," "gait performance," "diabetes mellitus," and "diabetic peripheral neuropathy." Results. Total of 4,337 studies were hit in the search. 1,524 studies were screened on their titles and citations. Then, 79 studies were screened on their abstract. Only 38 studies were eligible to be selected: 17 studies on postural control and 21 studies on the gait performance. Most previous researches were found to have strong evidence of postural control impairments and noticeable gait deficits in DPN. Deterioration of somatosensory, visual, and vestibular systems with the pathologic condition of diabetes on cognitive impairment causes further instability of postural and gait performance in DPN. Conclusions. Postural instability and gait imbalance in DPN may contribute to high risk of fall incidence, especially in the geriatric population. Thus, further works are crucial to highlight this fact in the hospital based and community adults.

  15. Near peripheral motion contrast threshold predicts older drivers' simulator performance.

    Science.gov (United States)

    Henderson, Steven; Gagnon, Sylvain; Collin, Charles; Tabone, Ricardo; Stinchcombe, Arne

    2013-01-01

    Our group has previously demonstrated that peripheral motion contrast threshold (PMCT) is significantly associated with self-reported accident risk of older drivers (questionnaire assessment), and with Useful Field of View(®) subtest 2 (UFOV2). It has not been shown, however, that PMCT is significantly associated with driving performance. Using the method of descending limits (spatial two-alternative forced choice) we assessed motion contrast thresholds of 28 young participants (25-45), and 21 older drivers (63-86) for 0.4 cycle/degree drifting Gabor stimuli at 15° eccentricity and examined whether it was related to performance on a simulated on-road test and to a measure of visual attention (UFOV(®) subtests 2 and 3). Peripheral motion contrast thresholds (PMCT) of younger participants were significantly lower than older participants. PMCT and UFOV2 significantly predicted driving examiners' scores of older drivers' simulator performance, as well as number of crashes. Within the older group, PMCT correlated significantly with UFOV2, UFOV3, and age. Within the younger group, PMCT was not significantly related to either UFOV(®) scores or age. Partial correlations showed that: substantial association between PMCT and UFOV2 was not age-related (within the older driver group); PMCT and UFOV2 tapped a common visual function; and PMCT assessed a component not captured by UFOV2. PMCT is potentially a useful assessment tool for predicting accident risk of older drivers, and for informing efforts to develop effective countermeasures to remediate this functional deficit as much as possible. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Visions and visioning in foresight activities

    DEFF Research Database (Denmark)

    Jørgensen, Michael Søgaard; Grosu, Dan

    2007-01-01

    The paper discusses the roles of visioning processes and visions in foresight activities and in societal discourses and changes parallel to or following foresight activities. The overall topic can be characterised as the dynamics and mechanisms that make visions and visioning processes work...... or not work. The theoretical part of the paper presents an actor-network theory approach to the analyses of visions and visioning processes, where the shaping of the visions and the visioning and what has made them work or not work is analysed. The empirical part is based on analyses of the roles of visions...... and visioning processes in a number of foresight processes from different societal contexts. The analyses have been carried out as part of the work in the COST A22 network on foresight. A vision is here understood as a description of a desirable or preferable future, compared to a scenario which is understood...

  17. Space, place and atmosphere. Emotion and peripherical perception in architectural experience

    Directory of Open Access Journals (Sweden)

    Juhani Pallasmaa

    2014-07-01

    Full Text Available Architectural experiences are essentially multi-sensory and simultaneous, and a complex entity is usually grasped as an atmosphere, ambience or feeling. In fact, the judgement concerning the character of a space or place calls for categories of sensing that extend beyond the five Aristotelian senses, such as the embodied existential sense, and, as a result, the entity is perceived in a diffuse, peripheral and unconscious manner. Paradoxically, we grasp an atmosphere before we have consciously identified its constituent factors and ingredients. «We perceive atmospheres through our emotional sensibility – a form of perception that works incredibly quickly, and which we humans evidently need to help us survive», Peter Zumthor suggests. We are mentally and emotionally affected by works of art before we understand them, or we may not understand them intellectually at all. Sensitive artists and architects intuit experiential and emotive qualities of spaces, places and images. This capacity calls for a specific kind of imagination, an emphatic imagination. Atmospheres are percieved peripherally through diffuse vision interacting with other sense modalities, and they are experienced emotionally rather than intellectually. The studies on the differentiation of the two brain hemispheres suggest that atmospheres are perceived through the right hemisphere. Somewhat surprisingly, atmospheres are more conscious objectives in literature, cinema, theater, painting and music than in architecture, which has been traditionally approached formally and perceived primarily through focused vision. Yet, when we see a thing in focus, we are outsiders to it, whereas the experience of being in a space calls for peripheral and unfocused perception. One of the reasons for the experiential poverty of contemporary settings could be in the poverty of their peripheral stimuli.

  18. Enhanced peripheral visual processing in congenitally deaf humans is supported by multiple brain regions, including primary auditory cortex

    OpenAIRE

    Scott, Gregory D.; Karns, Christina M.; Dow, Mark W.; Stevens, Courtney; Neville, Helen J.

    2014-01-01

    Brain reorganization associated with altered sensory experience clarifies the critical role of neuroplasticity in development. An example is enhanced peripheral visual processing associated with congenital deafness, but the neural systems supporting this have not been fully characterized. A gap in our understanding of deafness-enhanced peripheral vision is the contribution of primary auditory cortex. Previous studies of auditory cortex that use anatomical normalization across participants wer...

  19. Visual performance after bilateral implantation of 2 new presbyopia-correcting intraocular lenses: Trifocal versus extended range of vision.

    Science.gov (United States)

    Monaco, Gaspare; Gari, Mariangela; Di Censo, Fabio; Poscia, Andrea; Ruggi, Giada; Scialdone, Antonio

    2017-06-01

    To compare the visual outcomes and quality of vision of 2 new diffractive multifocal intraocular lenses (IOLs) with those of a monofocal IOL. Fatebenefratelli e Oftalmico Hospital, Milan, Italy. Prospective case series. Patients had bilateral cataract surgery with implantation of a trifocal IOL (Panoptix), an extended-range-of-vision IOL (Symfony), or a monofocal IOL (SN60WF). Postoperative examinations included assessing distance, intermediate, and near visual acuity; binocular defocus; intraocular and total aberrations; point-spread function (PSF); modulation transfer function (MTF); retinal straylight; and quality-of-vision (QoV) and spectacle-dependence questionnaires. Seventy-six patients (152 eyes) were assessed for study eligibility. Twenty patients (40 eyes) in each arm of the study (60 patients, 120 eyes) completed the outcome assessment. At the 4-month follow-up, the trifocal group had significantly better near visual acuity than the extended-range-of-vision group (P = .005). The defocus curve showed the trifocal IOL had better intermediate/near performance than the extended-range-of-vision IOL and both multifocal IOLs performed better than the monofocal IOL. Intragroup comparison of the total higher-order aberrations, PSF, MTF, and retinal straylight were not statistically different. The QoV questionnaire results showed no differences in dysphotopsia between the multifocal IOL groups; however, the results were significantly higher than in the monofocal IOL group. Both multifocal IOLs seemed to be good options for patients with intermediate-vision requirements, whereas the trifocal IOL might be better for patients with near-vision requirements. The significant perception of visual side effects indicates that patients still must be counseled about these effects before a multifocal IOL is implanted. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  20. Improving Mobility Performance in Low Vision With a Distance-Based Representation of the Visual Scene.

    Science.gov (United States)

    van Rheede, Joram J; Wilson, Iain R; Qian, Rose I; Downes, Susan M; Kennard, Christopher; Hicks, Stephen L

    2015-07-01

    Severe visual impairment can have a profound impact on personal independence through its effect on mobility. We investigated whether the mobility of people with vision low enough to be registered as blind could be improved by presenting the visual environment in a distance-based manner for easier detection of obstacles. We accomplished this by developing a pair of "residual vision glasses" (RVGs) that use a head-mounted depth camera and displays to present information about the distance of obstacles to the wearer as brightness, such that obstacles closer to the wearer are represented more brightly. We assessed the impact of the RVGs on the mobility performance of visually impaired participants during the completion of a set of obstacle courses. Participant position was monitored continuously, which enabled us to capture the temporal dynamics of mobility performance. This allowed us to find correlates of obstacle detection and hesitations in walking behavior, in addition to the more commonly used measures of trial completion time and number of collisions. All participants were able to use the smart glasses to navigate the course, and mobility performance improved for those visually impaired participants with the worst prior mobility performance. However, walking speed was slower and hesitations increased with the altered visual representation. A depth-based representation of the visual environment may offer low vision patients improvements in independent mobility. It is important for further work to explore whether practice can overcome the reductions in speed and increased hesitation that were observed in our trial.

  1. Vascular access in neonatology: peripherally inserted central catheter and peripheral venous catheter

    Directory of Open Access Journals (Sweden)

    Marcia Lienemann

    2014-04-01

    The objective of this paper is to present aspects of peripherally inserted central catheter and peripheral venous catheter, highlighting important points in choosing the type of access. For the passage of peripherally inserted central catheter is previously performing specific course necessary, while the primary indication occurs when it is necessary to access the patient's stay for a long period of time. Whereas peripheral venipuncture is the most appropriate in cases of needing an IV line quickly and safely, for the administration of fluids, blood collection, blood transfusion and other.

  2. Zilog UPC, a higher performance slave peripheral controller

    Energy Technology Data Exchange (ETDEWEB)

    Walters, S.M.

    1982-01-01

    The universal peripheral controllers Z8090 and Z8590 (UPC) is an intelligent peripheral controller. It may be mask-programmed to execute dedicated I/O tasks that would otherwise need to be done by the host microprocessor. The UPC is actually a single-chip microcomputer with a complete host bus interface on-chip. It offers the hardware features of a programmable parallel I/O port, a programmable counter/timer, an I/O buffer RAM, and an intelligent interrupt controller. In addition, it provides a stored program processing element that is capable of pre-processing information before it is transferred to the host. Perhaps as important as its features is the fact that when used in volume, the UPC will be comparable in cost to non-programmable LSI parallel I/O and counter/timer functions. The UPC, simply stated, offers a cost effective multi-processor approach for offloading the host microprocessor of routine peripheral control tasks in high volume applications.

  3. Progress in computer vision.

    Science.gov (United States)

    Jain, A. K.; Dorai, C.

    Computer vision has emerged as a challenging and important area of research, both as an engineering and a scientific discipline. The growing importance of computer vision is evident from the fact that it was identified as one of the "Grand Challenges" and also from its prominent role in the National Information Infrastructure. While the design of a general-purpose vision system continues to be elusive machine vision systems are being used successfully in specific application elusive, machine vision systems are being used successfully in specific application domains. Building a practical vision system requires a careful selection of appropriate sensors, extraction and integration of information from available cues in the sensed data, and evaluation of system robustness and performance. The authors discuss and demonstrate advantages of (1) multi-sensor fusion, (2) combination of features and classifiers, (3) integration of visual modules, and (IV) admissibility and goal-directed evaluation of vision algorithms. The requirements of several prominent real world applications such as biometry, document image analysis, image and video database retrieval, and automatic object model construction offer exciting problems and new opportunities to design and evaluate vision algorithms.

  4. Severe hypoxia affects exercise performance independently of afferent feedback and peripheral fatigue.

    Science.gov (United States)

    Millet, Guillaume Y; Muthalib, Makii; Jubeau, Marc; Laursen, Paul B; Nosaka, Kazunori

    2012-04-01

    To test the hypothesis that hypoxia centrally affects performance independently of afferent feedback and peripheral fatigue, we conducted two experiments under complete vascular occlusion of the exercising muscle under different systemic O(2) environmental conditions. In experiment 1, 12 subjects performed repeated submaximal isometric contractions of the elbow flexor to exhaustion (RCTE) with inspired O(2) fraction fixed at 9% (severe hypoxia, SevHyp), 14% (moderate hypoxia, ModHyp), 21% (normoxia, Norm), or 30% (hyperoxia, Hyper). The number of contractions (performance), muscle (biceps brachii), and prefrontal near-infrared spectroscopy (NIRS) parameters and high-frequency paired-pulse (PS100) evoked responses to electrical muscle stimulation were monitored. In experiment 2, 10 subjects performed another RCTE in SevHyp and Norm conditions in which the number of contractions, biceps brachii electromyography responses to electrical nerve stimulation (M wave), and transcranial magnetic stimulation responses (motor-evoked potentials, MEP, and cortical silent period, CSP) were recorded. Performance during RCTE was significantly reduced by 10-15% in SevHyp (arterial O(2) saturation, SpO(2) = ∼75%) compared with ModHyp (SpO(2) = ∼90%) or Norm/Hyper (SpO(2) > 97%). Performance reduction in SevHyp occurred despite similar 1) metabolic (muscle NIRS parameters) and functional (changes in PS100 and M wave) muscle states and 2) MEP and CSP responses, suggesting comparable corticospinal excitability and spinal and cortical inhibition between SevHyp and Norm. It is concluded that, in SevHyp, performance and central drive can be altered independently of afferent feedback and peripheral fatigue. It is concluded that submaximal performance in SevHyp is partly reduced by a mechanism related directly to brain oxygenation.

  5. Postural Control and Gait Performance in the Diabetic Peripheral Neuropathy: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Amirah Mustapa

    2016-01-01

    Full Text Available Purpose. The aim of this paper is to review the published studies on the characteristics of impairments in the postural control and gait performance in diabetic peripheral neuropathy (DPN. Methods. A review was performed by obtaining publication of all papers reporting on the postural control and gait performance in DPN from Google Scholar, Ovid, SAGE, Springerlink, Science Direct (SD, EBSCO Discovery Service, and Web of Science databases. The keywords used for searching were “postural control,” “balance,” “gait performance,” “diabetes mellitus,” and “diabetic peripheral neuropathy.” Results. Total of 4,337 studies were hit in the search. 1,524 studies were screened on their titles and citations. Then, 79 studies were screened on their abstract. Only 38 studies were eligible to be selected: 17 studies on postural control and 21 studies on the gait performance. Most previous researches were found to have strong evidence of postural control impairments and noticeable gait deficits in DPN. Deterioration of somatosensory, visual, and vestibular systems with the pathologic condition of diabetes on cognitive impairment causes further instability of postural and gait performance in DPN. Conclusions. Postural instability and gait imbalance in DPN may contribute to high risk of fall incidence, especially in the geriatric population. Thus, further works are crucial to highlight this fact in the hospital based and community adults.

  6. Bio-inspired vision

    International Nuclear Information System (INIS)

    Posch, C

    2012-01-01

    Nature still outperforms the most powerful computers in routine functions involving perception, sensing and actuation like vision, audition, and motion control, and is, most strikingly, orders of magnitude more energy-efficient than its artificial competitors. The reasons for the superior performance of biological systems are subject to diverse investigations, but it is clear that the form of hardware and the style of computation in nervous systems are fundamentally different from what is used in artificial synchronous information processing systems. Very generally speaking, biological neural systems rely on a large number of relatively simple, slow and unreliable processing elements and obtain performance and robustness from a massively parallel principle of operation and a high level of redundancy where the failure of single elements usually does not induce any observable system performance degradation. In the late 1980's, Carver Mead demonstrated that silicon VLSI technology can be employed in implementing ''neuromorphic'' circuits that mimic neural functions and fabricating building blocks that work like their biological role models. Neuromorphic systems, as the biological systems they model, are adaptive, fault-tolerant and scalable, and process information using energy-efficient, asynchronous, event-driven methods. In this paper, some basics of neuromorphic electronic engineering and its impact on recent developments in optical sensing and artificial vision are presented. It is demonstrated that bio-inspired vision systems have the potential to outperform conventional, frame-based vision acquisition and processing systems in many application fields and to establish new benchmarks in terms of redundancy suppression/data compression, dynamic range, temporal resolution and power efficiency to realize advanced functionality like 3D vision, object tracking, motor control, visual feedback loops, etc. in real-time. It is argued that future artificial vision systems

  7. Rodent model for assessing the long term safety and performance of peripheral nerve recording electrodes

    Science.gov (United States)

    Vasudevan, Srikanth; Patel, Kunal; Welle, Cristin

    2017-02-01

    Objective. In the US alone, there are approximately 185 000 cases of limb amputation annually, which can reduce the quality of life for those individuals. Current prosthesis technology could be improved by access to signals from the nervous system for intuitive prosthesis control. After amputation, residual peripheral nerves continue to convey motor signals and electrical stimulation of these nerves can elicit sensory percepts. However, current technology for extracting information directly from peripheral nerves has limited chronic reliability, and novel approaches must be vetted to ensure safe long-term use. The present study aims to optimize methods to establish a test platform using rodent model to assess the long term safety and performance of electrode interfaces implanted in the peripheral nerves. Approach. Floating Microelectrode Arrays (FMA, Microprobes for Life Sciences) were implanted into the rodent sciatic nerve. Weekly in vivo recordings and impedance measurements were performed in animals to assess performance and physical integrity of electrodes. Motor (walking track analysis) and sensory (Von Frey) function tests were used to assess change in nerve function due to the implant. Following the terminal recording session, the nerve was explanted and the health of axons, myelin and surrounding tissues were assessed using immunohistochemistry (IHC). The explanted electrodes were visualized under high magnification using scanning electrode microscopy (SEM) to observe any physical damage. Main results. Recordings of axonal action potentials demonstrated notable session-to-session variability. Impedance of the electrodes increased upon implantation and displayed relative stability until electrode failure. Initial deficits in motor function recovered by 2 weeks, while sensory deficits persisted through 6 weeks of assessment. The primary cause of failure was identified as lead wire breakage in all of animals. IHC indicated myelinated and unmyelinated axons

  8. Impact of low vision care on reading performance in children with multiple disabilities and visual impairment

    Directory of Open Access Journals (Sweden)

    Krishna Kumar Ramani

    2014-01-01

    Full Text Available Background: Lack of evidence in literature to show low vision care enhances the reading performance in children with Multiple Disabilities and Visual Impairment (MDVI. Aim: To evaluate the effectiveness of Low Vision Care intervention on the reading performance of children with MDVI. Materials and Methods: Three subjects who were diagnosed to have cerebral palsy and visual impairment, studying in a special school were recruited for the study. All of them underwent detailed eye examination and low vision care evaluation at a tertiary eye care hospital. A single subject multiple baseline (study design was adopted and the study period was 16 weeks. The reading performance (reading speed, reading accuracy, reading fluency was evaluated during the baseline phase and the intervention phase. The median of all the reading parameters for each week was noted. The trend of the reading performance was graphically represented in both the phases. Results: Reading speed increased by 37 Word per minute, 37 Letters per minute and 5 letters per minute for the subject 1, 2 and 3 respectively after the intervention. Reading accuracy was 84%, 91% and 86.4% at the end of the baseline period and 98.7%, 98.4% and 99% at the end of 16 weeks for subject 1, 2 and 3 respectively. Average reading fluency score was 8.3, 7.1 and 5.5 in the baseline period and 10.2, 10.2 and 8.7 in the intervention period. Conclusion: This study shows evidence of noticeable improvement in reading performance of children with MDVI using a novel study design.

  9. Vision systems for scientific and engineering applications

    International Nuclear Information System (INIS)

    Chadda, V.K.

    2009-01-01

    Human performance can get degraded due to boredom, distraction and fatigue in vision-related tasks such as measurement, counting etc. Vision based techniques are increasingly being employed in many scientific and engineering applications. Notable advances in this field are emerging from continuing improvements in the fields of sensors and related technologies, and advances in computer hardware and software. Automation utilizing vision-based systems can perform repetitive tasks faster and more accurately, with greater consistency over time than humans. Electronics and Instrumentation Services Division has developed vision-based systems for several applications to perform tasks such as precision alignment, biometric access control, measurement, counting etc. This paper describes in brief four such applications. (author)

  10. Relationships Between Measures of the Ability to Perform Vision-Related Activities, Vision-Related Quality of Life, and Clinical Findings in Patients With Glaucoma.

    Science.gov (United States)

    Ekici, Feyzahan; Loh, Rebecca; Waisbourd, Michael; Sun, Yi; Martinez, Patricia; Nayak, Natasha; Wizov, Sheryl S; Hegarty, Sarah; Hark, Lisa A; Spaeth, George L

    2015-12-01

    To our knowledge, few studies have combined an objective measure of vision-related performance (VRP) and subjective measures of vision-related quality of life (VRQoL) with clinically related visual parameters, particularly in a large, prospective, cohort study setting. To examine the relationships between clinical visual assessments and both a VRP and 2 self-reported VRQoL measurements. Patients (N = 161) with moderate-stage glaucoma recruited from the Glaucoma Service at Wills Eye Hospital, Philadelphia, Pennsylvania, were enrolled from May 2012 to May 2014 in an ongoing prospective, 4-year longitudinal observational study. This report includes cross-sectional results from the baseline visit. Patients received a complete ocular examination, automated visual field (VF) test and Cirrus optical coherence tomographic scan. Contrast sensitivity was measured with the Pelli-Robson and the Spaeth-Richman Contrast Sensitivity (SPARCS) tests. Vision-related performance was assessed by the Compressed Assessment of Ability Related to Vision (CAARV) test. Vision-related QoL was assessed by the National Eye Institute Visual Function Questionnaire 25 (NEI-VFQ-25) and a modified Glaucoma Symptom Scale (MGSS). Correlations between clinical measures and CAARV, NEI-VFQ-25, and MGSS scores. A total of 161 patients were enrolled in the study. The strongest correlation was found between SPARCS score in the better eye and total CAARV score (r = 0.398; 95% CI, 0.235-0.537; P better eye. There were more statistically significant correlations between contrast sensitivity tests and VF mean deviation with VRQoL measurements than with other clinical measures (visual acuity, intraocular pressure, Disc Damage Likelihood Scale, and mean retinal nerve fiber layer thickness). The MGSS scores were lower (worse) in women compared with men (P = .03 for binocular, P = .01 for better eye, and P = .05 for the worse eye). Structural measures (eg, Disc Damage Likelihood Scale, and

  11. Peripheral visual feedback: a powerful means of supporting effective attention allocation in event-driven, data-rich environments.

    Science.gov (United States)

    Nikolic, M I; Sarter, N B

    2001-01-01

    Breakdowns in human-automation coordination in data-rich, event-driven domains such as aviation can be explained in part by a mismatch between the high degree of autonomy yet low observability of modern technology. To some extent, the latter is the result of an increasing reliance in feedback design on foveal vision--an approach that fails to support pilots in tracking system-induced changes and events in parallel with performing concurrent flight-related tasks. One possible solution to the problem is the distribution of tasks and information across sensory modalities and processing channels. A simulator study is presented that compared the effectiveness of current foveal feedback and two implementations of peripheral visual feedback for keeping pilots informed about uncommanded changes in the status of an automated cockpit system. Both peripheral visual displays resulted in higher detection rates and faster response times, without interfering with the performance of concurrent visual tasks any more than does currently available automation feedback. Potential applications include improved display designs that support effective attention allocation in a variety of complex dynamic environments, such as aviation, process control, and medicine.

  12. ABCs of foveal vision

    Science.gov (United States)

    Matchko, Roy M.; Gerhart, Grant R.

    2001-12-01

    This paper presents a simple mathematical performance model of the human foveal vision system based on an extensive analysis of the Blackwell-McCready (BM) data set. It includes a closed-form equation, the (ABC)t law, that allows the analyst to predict the entire range of BM threshold data. Relationships are derived among the four fundamental parameters of foveal vision: target area A, background luminance B, threshold contrast C, and stimulus presentation time t. Hyperbolic-curve fits on log-log plots of the data lead to the well-known laws of Ricco, Blackwell, Weber and Fechner, and Bloch. This paper unifies important relationships associated with target and background scene parameters as they relate to the human foveal vision process. The process of detecting a BM target, using foveal vision, is reduced to the total temporal summation of light energy modified by a multiplicative energy ratio. A stochastic model of human observer performance is presented in terms of a cumulative Gaussian distribution, which is a function of the apparent and BM contrast threshold values.

  13. A new measure for the assessment of visual awareness in individuals with tunnel vision.

    Science.gov (United States)

    AlSaqr, Ali M; Dickinson, Chris M

    2017-01-01

    Individuals with a restricted peripheral visual field or tunnel vision (TV) have problems moving about and avoiding obstacles. Some individuals adapt better than others and some use assistive optical aids, so measurement of the visual field is not sufficient to describe their performance. In the present study, we developed a new clinical test called the 'Assessment of Visual Awareness (AVA)', which can be used to measure detection of peripheral targets. The participants were 20 patients with TV due to retinitis pigmentosa (PTV) and 50 normally sighted participants with simulated tunnel vision (STV) using goggles. In the AVA test, detection times were measured, when subjects searched for 24 individually presented, one degree targets, randomly positioned in a 60 degrees noise background. Head and eye movements were allowed and the presentation time was unlimited. The test validity was investigated by correlating the detection times with the 'percentage of preferred walking speed' (PPWS) and the 'number of collisions' on an indoor mobility course. In PTV and STV, the detection times had significant negative correlation with the field of view. The detection times had significant positive relations with target location. In the STV, the detection time was significantly negatively correlated with the PPWS and significantly positively correlated with the collisions score on the indoor mobility course. In the PTV, the relationship was not statistically significant. No significant difference in performance of STV was found when repeating the test one to two weeks later. The proposed AVA test was sensitive to the field of view and target location. The test is unique in design, quick, simple to deliver and both repeatable and valid. It could be a valuable tool to test different rehabilitation strategies in patients with TV. © 2016 Optometry Australia.

  14. Immediate and intermediate-term results of optical coherence tomography guided atherectomy in the treatment of peripheral arterial disease: Initial results from the VISION trial

    International Nuclear Information System (INIS)

    Cawich, Ian; Paixao, Andre R.M.; Marmagkiolis, Konstantinos; Lendel, Vasili; Rodriguez-Araujo, Gerardo; Rollefson, William A.; Mego, David M.; Cilingiroglu, Mehmet

    2016-01-01

    Background: Long-term patency rates for percutaneous peripheral arterial interventions are suboptimal. Optical coherence tomography (OCT) guided atherectomy may yield superior patency by optimizing plaque removal while preserving the tunica media and adventitia. Methods: The VISION study is a multicenter prospective study of patients with peripheral arterial disease undergoing OCT guided atherectomy with the Pantheris™ device. In 11 patients enrolled in a single center, we report procedural and clinical outcomes, at 30 days and 6 months. Results: The mean age was 63 ± 11 years and 73% (n = 8) were men. The target lesion was in the superficial femoral artery in 82% (n = 9) of the patients. Mean stenosis severity was 87% ± 10% and mean lesion length was 39 ± 31 mm. Procedural success was observed in all patients with no device related complications. Mean post-atherectomy stenosis was 18% ± 15%. Almost all excised tissue consisted of intimal plaque (94%). At 30 days, significant improvements in Rutherford class, VascuQoL scores and ABI were observed, 0.9 ± 0.8 vs. 3.1 ± 0.7 (p = 0.01), 4.9 ± 1.9 vs. 3.6 ± 1.5 (p = 0.03) and 1.04 ± 0.19 vs. 0.80 ± 0.19 (p < 0.01) respectively. At 6 months, there were significant improvements in Rutherford class (1.0 ± 1.0 vs. 3.1 ± 0.7, p = 0.01) and ABI (0.93 ± 0.19 versus 0.80 ± 0.19, p = 0.02) but not in VascuQoL scores (3.7 ± 1.4 versus 3.6 ± 1.5, p = 0.48). Target lesion revascularization occurred in 18% (n = 2) of the patients. Conclusion: OCT guided atherectomy resulted in high procedural success, no device related complications and encouraging results up to 6 months. Histological analysis suggested little injury to the media and adventitia. Larger studies are needed to confirm the efficacy of this approach. - Highlights: • OCT- guided atherectomy may yield superior patency by optimizing plaque removal and preserving the tunica media and adventitia. • OCT guided atherectomy resulted in high procedural

  15. Immediate and intermediate-term results of optical coherence tomography guided atherectomy in the treatment of peripheral arterial disease: Initial results from the VISION trial

    Energy Technology Data Exchange (ETDEWEB)

    Cawich, Ian; Paixao, Andre R.M. [Arkansas Heart Hospital, Peripheral Vascular Institute, Little Rock, AR (United States); Marmagkiolis, Konstantinos [Citizens Memorial Heart and Vascular Institute, Bolivar, MO (United States); University of Missouri, Columbia, MO (United States); Lendel, Vasili; Rodriguez-Araujo, Gerardo; Rollefson, William A.; Mego, David M. [Arkansas Heart Hospital, Peripheral Vascular Institute, Little Rock, AR (United States); Cilingiroglu, Mehmet, E-mail: Cilingiroglumehmet@gmail.com [Arkansas Heart Hospital, Peripheral Vascular Institute, Little Rock, AR (United States); Koc University, School of Medicine, Istanbul (Turkey)

    2016-10-15

    Background: Long-term patency rates for percutaneous peripheral arterial interventions are suboptimal. Optical coherence tomography (OCT) guided atherectomy may yield superior patency by optimizing plaque removal while preserving the tunica media and adventitia. Methods: The VISION study is a multicenter prospective study of patients with peripheral arterial disease undergoing OCT guided atherectomy with the Pantheris™ device. In 11 patients enrolled in a single center, we report procedural and clinical outcomes, at 30 days and 6 months. Results: The mean age was 63 ± 11 years and 73% (n = 8) were men. The target lesion was in the superficial femoral artery in 82% (n = 9) of the patients. Mean stenosis severity was 87% ± 10% and mean lesion length was 39 ± 31 mm. Procedural success was observed in all patients with no device related complications. Mean post-atherectomy stenosis was 18% ± 15%. Almost all excised tissue consisted of intimal plaque (94%). At 30 days, significant improvements in Rutherford class, VascuQoL scores and ABI were observed, 0.9 ± 0.8 vs. 3.1 ± 0.7 (p = 0.01), 4.9 ± 1.9 vs. 3.6 ± 1.5 (p = 0.03) and 1.04 ± 0.19 vs. 0.80 ± 0.19 (p < 0.01) respectively. At 6 months, there were significant improvements in Rutherford class (1.0 ± 1.0 vs. 3.1 ± 0.7, p = 0.01) and ABI (0.93 ± 0.19 versus 0.80 ± 0.19, p = 0.02) but not in VascuQoL scores (3.7 ± 1.4 versus 3.6 ± 1.5, p = 0.48). Target lesion revascularization occurred in 18% (n = 2) of the patients. Conclusion: OCT guided atherectomy resulted in high procedural success, no device related complications and encouraging results up to 6 months. Histological analysis suggested little injury to the media and adventitia. Larger studies are needed to confirm the efficacy of this approach. - Highlights: • OCT- guided atherectomy may yield superior patency by optimizing plaque removal and preserving the tunica media and adventitia. • OCT guided atherectomy resulted in high procedural

  16. Immediate and intermediate-term results of optical coherence tomography guided atherectomy in the treatment of peripheral arterial disease: Initial results from the VISION trial.

    Science.gov (United States)

    Cawich, Ian; Paixao, Andre R M; Marmagkiolis, Konstantinos; Lendel, Vasili; Rodriguez-Araujo, Gerardo; Rollefson, William A; Mego, David M; Cilingiroglu, Mehmet

    Long-term patency rates for percutaneous peripheral arterial interventions are suboptimal. Optical coherence tomography (OCT) guided atherectomy may yield superior patency by optimizing plaque removal while preserving the tunica media and adventitia. The VISION study is a multicenter prospective study of patients with peripheral arterial disease undergoing OCT guided atherectomy with the Pantheris™ device. In 11 patients enrolled in a single center, we report procedural and clinical outcomes, at 30days and 6months. The mean age was 63±11years and 73% (n=8) were men. The target lesion was in the superficial femoral artery in 82% (n=9) of the patients. Mean stenosis severity was 87%±10% and mean lesion length was 39±31mm. Procedural success was observed in all patients with no device related complications. Mean post-atherectomy stenosis was 18%±15%. Almost all excised tissue consisted of intimal plaque (94%). At 30days, significant improvements in Rutherford class, VascuQoL scores and ABI were observed, 0.9±0.8 vs. 3.1±0.7 (p=0.01), 4.9±1.9 vs. 3.6±1.5 (p=0.03) and 1.04±0.19 vs. 0.80±0.19 (patherectomy resulted in high procedural success, no device related complications and encouraging results up to 6months. Histological analysis suggested little injury to the media and adventitia. Larger studies are needed to confirm the efficacy of this approach. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. [Ultrasound-guided peripheral catheterization].

    Science.gov (United States)

    Salleras-Duran, Laia; Fuentes-Pumarola, Concepció

    2016-01-01

    Peripheral catheterization is a technique that can be difficult in some patients. Some studies have recently described the use of ultrasound to guide the venous catheterization. To describe the success rate, time required, complications of ultrasound-guided peripheral venous catheterization. and patients and professionals satisfaction The search was performed in databases (Medline-PubMed, Cochrane Library, CINAHL and Cuiden Plus) for studies published about ultrasound-guided peripheral venous catheterization performed on patients that provided results on the success of the technique, complications, time used, patient satisfaction and the type of professional who performed the technique. A total of 21 studies were included. Most of them get a higher success rate 80% in the catheterization ecoguide and time it is not higher than the traditional technique. The Technical complications analyzed were arterial puncture rates and lower nerve 10%. In all studies measuring and comparing patient satisfaction in the art ecoguide is greater. Various professional groups perform the technique. The use of ultrasound for peripheral pipes has a high success rate, complications are rare and the time used is similar to that of the traditional technique. The technique of inserting catheters through ultrasound may be learned by any professional group performing venipuncture. Finally, it gets underscores the high patient satisfaction with the use of this technique. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  18. Motion-Base Simulator Evaluation of an Aircraft Using an External Vision System

    Science.gov (United States)

    Kramer, Lynda J.; Williams, Steven P.; Arthur, J. J.; Rehfeld, Sherri A.; Harrison, Stephanie

    2012-01-01

    Twelve air transport-rated pilots participated as subjects in a motion-base simulation experiment to evaluate the use of eXternal Vision Systems (XVS) as enabling technologies for future supersonic aircraft without forward facing windows. Three head-up flight display concepts were evaluated -a monochromatic, collimated Head-up Display (HUD) and a color, non-collimated XVS display with a field-of-view (FOV) equal to and also, one significantly larger than the collimated HUD. Approach, landing, departure, and surface operations were conducted. Additionally, the apparent angle-of-attack (AOA) was varied (high/low) to investigate the vertical field-of-view display requirements and peripheral, side window visibility was experimentally varied. The data showed that lateral approach tracking performance and lateral landing position were excellent regardless of AOA, display FOV, display collimation or whether peripheral cues were present. However, the data showed glide slope approach tracking appears to be affected by display size (i.e., FOV) and collimation. The monochrome, collimated HUD and color, uncollimated XVS with Full FOV display had (statistically equivalent) glide path performance improvements over the XVS with HUD FOV display. Approach path performance results indicated that collimation may not be a requirement for an XVS display if the XVS display is large enough and employs color. Subjective assessments of mental workload and situation awareness also indicated that an uncollimated XVS display may be feasible. Motion cueing appears to have improved localizer tracking and touchdown sink rate across all displays.

  19. Vision/INS Integrated Navigation System for Poor Vision Navigation Environments

    Directory of Open Access Journals (Sweden)

    Youngsun Kim

    2016-10-01

    Full Text Available In order to improve the performance of an inertial navigation system, many aiding sensors can be used. Among these aiding sensors, a vision sensor is of particular note due to its benefits in terms of weight, cost, and power consumption. This paper proposes an inertial and vision integrated navigation method for poor vision navigation environments. The proposed method uses focal plane measurements of landmarks in order to provide position, velocity and attitude outputs even when the number of landmarks on the focal plane is not enough for navigation. In order to verify the proposed method, computer simulations and van tests are carried out. The results show that the proposed method gives accurate and reliable position, velocity and attitude outputs when the number of landmarks is insufficient.

  20. Vision Assessment and Prescription of Low Vision Devices

    OpenAIRE

    Keeffe, Jill

    2004-01-01

    Assessment of vision and prescription of low vision devices are part of a comprehensive low vision service. Other components of the service include training the person affected by low vision in use of vision and other senses, mobility, activities of daily living, and support for education, employment or leisure activities. Specialist vision rehabilitation agencies have services to provide access to information (libraries) and activity centres for groups of people with impaired vision.

  1. Vision in high-level football officials.

    Science.gov (United States)

    Baptista, António Manuel Gonçalves; Serra, Pedro M; McAlinden, Colm; Barrett, Brendan T

    2017-01-01

    Officiating in football depends, at least to some extent, upon adequate visual function. However, there is no vision standard for football officiating and the nature of the relationship between officiating performance and level of vision is unknown. As a first step in characterising this relationship, we report on the clinically-measured vision and on the perceived level of vision in elite-level, Portuguese football officials. Seventy-one referees (R) and assistant referees (AR) participated in the study, representing 92% of the total population of elite level football officials in Portugal in the 2013/2014 season. Nine of the 22 Rs (40.9%) and ten of the 49 ARs (20.4%) were international-level. Information about visual history was also gathered. Perceived vision was assessed using the preference-values-assigned-to-global-visual-status (PVVS) and the Quality-of-Vision (QoV) questionnaire. Standard clinical vision measures (including visual acuity, contrast sensitivity and stereopsis) were gathered in a subset (n = 44, 62%) of the participants. Data were analysed according to the type (R/AR) and level (international/national) of official, and Bonferroni corrections were applied to reduce the risk of type I errors. Adopting criterion for statistical significance of pfootball officials were similar to published normative values for young, adult populations and similar between R and AR. Clinically-measured vision did not differ according to officiating level. Visual acuity measured with and without a pinhole disc indicated that around one quarter of participants may be capable of better vision when officiating, as evidenced by better acuity (≥1 line of letters) using the pinhole. Amongst the clinical visual tests we used, we did not find evidence for above-average performance in elite-level football officials. Although the impact of uncorrected mild to moderate refractive error upon officiating performance is unknown, with a greater uptake of eye examinations, visual

  2. An Uncommon Ocular Finding in Behçet’s Disease: Peripheral Ulcerative Keratitis

    Directory of Open Access Journals (Sweden)

    Orhan Ayar

    2014-12-01

    Full Text Available A 43-year-old female patient presented to our eye clinic with blurred vision and redness in the right eye for 2 weeks. Biomicroscopic examination revealed peripheral ulcerative keratitis with corneal thinning. After prescribing topical fluorometholon, moxifloxacin, preservative-free artificial tears, and vitamin A ointment, the patient was referred to Rheumatology department. Based on clinical findings and systemic research, the diagnosis of Behçet’s disease was established, and oral systemic azathioprine, hydroxychloroquine, and prednisolone treatment was started. In this study, we presented a case of peripheral ulcerative keratitis, an ocular manifestation uncommonly seen in Behçet’s disease. (Turk J Ophthalmol 2014; 44: 484-5

  3. Performance-based Physical Functioning and Peripheral Neuropathy in a Population-based Cohort of Women at Midlife

    Science.gov (United States)

    Ylitalo, Kelly R.; Herman, William H.; Harlow, Siobán D.

    2013-01-01

    Peripheral neuropathy is underappreciated as a potential cause of functional limitations. In the present article, we assessed the cross-sectional association between peripheral neuropathy and physical functioning and how the longitudinal association between age and functioning differed by neuropathy status. Physical functioning was measured in 1996–2008 using timed performances on stair-climb, walking, sit-to-stand, and balance tests at the Michigan site of the Study of Women's Health Across the Nation, a population-based cohort study of women at midlife (n = 396). Peripheral neuropathy was measured in 2008 and defined as having an abnormal monofilament test result or 4 or more symptoms. We used linear mixed models to determine whether trajectories of physical functioning differed by prevalent neuropathy status. Overall, 27.8% of the women had neuropathy. Stair-climb time differed by neuropathy status (P = 0.04), and for every 1-year increase in age, women with neuropathy had a 1.82% (95% confidence interval: 1.42, 2.21) increase compared with a 0.95% (95% confidence interval: 0.71, 1.20) increase for women without neuropathy. Sit-to-stand time differed by neuropathy status (P = 0.01), but the rate of change did not differ. No differences between neuropathy groups were observed for the walk test. For some performance-based tasks, poor functioning was maintained or exacerbated for women who had prevalent neuropathy. Peripheral neuropathy may play a role in physical functioning limitations and future disability. PMID:23524038

  4. Laser peripheral iridoplasty for angle-closure.

    Science.gov (United States)

    Ng, Wai Siene; Ang, Ghee Soon; Azuara-Blanco, Augusto

    2012-02-15

    Angle-closure glaucoma is a leading cause of irreversible blindness in the world. Treatment is aimed at opening the anterior chamber angle and lowering the IOP with medical and/or surgical treatment (e.g. trabeculectomy, lens extraction). Laser iridotomy works by eliminating pupillary block and widens the anterior chamber angle in the majority of patients. When laser iridotomy fails to open the anterior chamber angle, laser iridoplasty may be recommended as one of the options in current standard treatment for angle-closure. Laser peripheral iridoplasty works by shrinking and pulling the peripheral iris tissue away from the trabecular meshwork. Laser peripheral iridoplasty can be used for crisis of acute angle-closure and also in non-acute situations.   To assess the effectiveness of laser peripheral iridoplasty in the treatment of narrow angles (i.e. primary angle-closure suspect), primary angle-closure (PAC) or primary angle-closure glaucoma (PACG) in non-acute situations when compared with any other intervention. In this review, angle-closure will refer to patients with narrow angles (PACs), PAC and PACG. We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2011, Issue 12), MEDLINE (January 1950 to January 2012), EMBASE (January 1980 to January 2012), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to January 2012), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). There were no date or language restrictions in the electronic searches for trials. The electronic databases were last searched on 5 January 2012. We included only randomised controlled trials (RCTs) in this review. Patients with narrow angles, PAC or PACG were eligible. We excluded studies that included only patients with acute presentations

  5. Evaluation of functional color vision requirements and current color vision screening tests for air traffic control specialists.

    Science.gov (United States)

    1990-08-01

    An experiment was conducted to evaluate the relation of type and degree of color vision deficiency and aeromedical color vision screening test scores to performance of color-dependent tasks of Air Traffic Control Specialists. The subjects included 37...

  6. Peripheral doses of cranial pediatric IMRT performed with attenuator blocks

    International Nuclear Information System (INIS)

    Soboll, Danyel Scheidegger; Schitz, Ivette; Schelin, Hugo Reuters; Silva, Ricardo Goulart da; Viamonte, Alfredo

    2011-01-01

    This paper presents values of peripheral doses measured at six vital points of simulator objects which represent the ages of 2, 5 and 10 years old, submitted to a cranial IMRT procedure that applied compensator blocks interposed to 6 MV beams. The found values indicate that there is independence of dose with position of measurements and age of the patient, as the peripheral dose at the points nearest and the 2 year old simulator object where larger. The doses in thyroid reached the range of 1.4 to 2.9% of the dose prescribed in the isocenter, indicating that the peripheral doses for IMRT that employ compensator blocks can be greater than for the IMRT produced with sliding window technique

  7. Effects of Motion in the Far Peripheral Visual Field on Cognitive Test Performance and Cognitive Load.

    Science.gov (United States)

    Bevilacqua, Andy; Paas, Fred; Krigbaum, Genomary

    2016-04-01

    Cognitive load theory posits that limited attention is in actuality a limitation in working memory resources. The load theory of selective attention and cognitive control sees the interplay between attention and awareness as separate modifying functions that act on working memory. Reconciling the theoretical differences in these two theories has important implications for learning. Thirty-nine adult participants performed a cognitively demanding test, with and without movement in the far peripheral field. Although the results for movement effects on cognitive load in this experiment were not statistically significant, men spent less time on the cognitive test in the peripheral movement condition than in the conditions without peripheral movement. No such difference was found for women. The implications of these results and recommendations for future research that extends the present study are presented. © The Author(s) 2016.

  8. Impact of low vision rehabilitation on functional vision performance of children with visual impairment

    Directory of Open Access Journals (Sweden)

    Suma Ganesh

    2013-01-01

    Conclusions: In our study group, there was a significant improvement in functional vision post visual rehabilitation, especially with those activities which are related to their academic output. It is important for these children to have an early visual rehabilitation to decrease the impairment associated with these decreased visual output and to enhance their learning abilities.

  9. A visual test based on a freeware software for quantifying and displaying night-vision disturbances: study in subjects after alcohol consumption.

    Science.gov (United States)

    Castro, José J; Ortiz, Carolina; Pozo, Antonio M; Anera, Rosario G; Soler, Margarita

    2014-05-07

    In this work, we propose the Halo test, a simple visual test based on a freeware software for quantifying and displaying night-vision disturbances perceived by subjects under different experimental conditions, more precisely studying the influence of the alcohol consumption on visual function. In the Halo test, viewed on a monitor, the subject's task consists of detecting luminous peripheral stimuli around a central high-luminance stimulus over a dark background. The test, performed by subjects before and after consuming alcoholic drinks, which deteriorate visual performance, evaluates the influence that alcohol consumption exerts on the visual-discrimination capacity under low illumination conditions. Measurements were made monocularly and binocularly. Pupil size was also measured in both conditions (pre/post). Additionally, we used a double-pass device to measure objectively the optical-quality of the eye and corroborate the results from the Halo test. We found a significant deterioration of the discrimination capacity after alcohol consumption, indicating that the higher the breath-alcohol content, the greater the deterioration of the visual-discrimination capacity. After alcohol intake, the graphical results showed a greater area of undetected peripheral stimuli around the central high-luminance stimulus. An enlargement of the pupil was also observed and the optical quality of the eye was deteriorated after alcohol consumption. A greater influence of halos and other night-vision disturbances were reported with the Halo test after alcohol consumption. The Halo freeware software constitutes a positive contribution for evaluating nighttime visual performance in clinical applications, such as reported here, but also in patients after refractive surgery (where halos are present) or for monitoring (time course) some ocular pathologies under pharmacological treatment.

  10. Low Vision

    Science.gov (United States)

    ... USAJobs Home » Statistics and Data » Low Vision Listen Low Vision Low Vision Defined: Low Vision is defined as the best- ... Ethnicity 2010 U.S. Age-Specific Prevalence Rates for Low Vision by Age, and Race/Ethnicity Table for 2010 ...

  11. Reproducibility of an objective four-choice canine vision testing technique that assesses vision at differing light intensities.

    Science.gov (United States)

    Annear, Matthew J; Gornik, Kara R; Venturi, Francesca L; Hauptman, Joe G; Bartoe, Joshua T; Petersen-Jones, Simon M

    2013-09-01

    The increasing importance of canine retinal dystrophy models means accurate vision testing is needed. This study was performed to evaluate a four-choice vision testing technique for any difference in outcome measures with repeated evaluations of the same dogs.   Four 11-month-old RPE65-deficient dogs. Vision was evaluated using a previously described four-choice vision testing device. Four evaluations were performed at 2-week intervals. Vision was assessed at six different white light intensities (bright through dim), and each eye was evaluated separately. The ability to select the one of the four exit tunnels that was open at the far end was assessed ('choice of exit') and recorded as correct or incorrect first tunnel choice. 'Time to exit' the device was also recorded. Both outcomes were analyzed for significance using anova. We hypothesized that performance would improve with repeated testing (more correct choices and more rapid time to exit). 'Choice of exit' did not vary significantly between each evaluation (P = 0.12), in contrast 'time to exit' increased significantly (P = 0.012), and showed greater variability in dim light conditions. We found no evidence to support the hypothesis that either measure of outcome worsened with repeated testing; in fact, the 'time to exit' outcome worsened rather than improved. The 'choice of exit' gave consistent results between trials. These outcome data indicate the importance of including a choice-based assessment of vision in addition to measurement of device transit time. © 2012 American College of Veterinary Ophthalmologists.

  12. Machine Vision Tests for Spent Fuel Scrap Characteristics

    International Nuclear Information System (INIS)

    BERGER, W.W.

    2000-01-01

    The purpose of this work is to perform a feasibility test of a Machine Vision system for potential use at the Hanford K basins during spent nuclear fuel (SNF) operations. This report documents the testing performed to establish functionality of the system including quantitative assessment of results. Fauske and Associates, Inc., which has been intimately involved in development of the SNF safety basis, has teamed with Agris-Schoen Vision Systems, experts in robotics, tele-robotics, and Machine Vision, for this work

  13. Conditions Affecting the Performance of Peripheral Vein Cannulation during Hospital Placement: A Case Study

    Directory of Open Access Journals (Sweden)

    Monika Ravik

    2017-01-01

    Full Text Available Learning practical nursing skills is an important part of the baccalaureate in nursing. However, many newly qualified nurses lack practical skill proficiency required to ensure safe patient care. The invasive skill peripheral vein cannulation (PVC is particularly challenging to learn and perform. This study explored conditions influencing nursing students’ learning and performance of the technical implementation of a PVC during their clinical placement period. A qualitative and descriptive case study design with two students in Norway practicing PVC during their clinical placement was conducted. One student who mastered the vein cannulation was compared with one student who did not. Data were collected in late 2012 using multiple data sources: semistructured interviews, ad hoc conversations, and video recordings. Video recordings of the two students’ cannula implementations were used to help clarify and validate the descriptions and to identify gaps between what students said and what they did. Thematic analysis of the transcribed text data enabled identifying themes that influenced skill performance. There were two overall themes: individual and contextual conditions influencing the technical implementation of a peripheral vein cannula. These findings were evaluated in terms of Benner’s work on scientific and practical knowledge, defined as “knowing that” and “knowing how.”

  14. Functional programming for computer vision

    Science.gov (United States)

    Breuel, Thomas M.

    1992-04-01

    Functional programming is a style of programming that avoids the use of side effects (like assignment) and uses functions as first class data objects. Compared with imperative programs, functional programs can be parallelized better, and provide better encapsulation, type checking, and abstractions. This is important for building and integrating large vision software systems. In the past, efficiency has been an obstacle to the application of functional programming techniques in computationally intensive areas such as computer vision. We discuss and evaluate several 'functional' data structures for representing efficiently data structures and objects common in computer vision. In particular, we will address: automatic storage allocation and reclamation issues; abstraction of control structures; efficient sequential update of large data structures; representing images as functions; and object-oriented programming. Our experience suggests that functional techniques are feasible for high- performance vision systems, and that a functional approach simplifies the implementation and integration of vision systems greatly. Examples in C++ and SML are given.

  15. Visual acuity and contrast sensitivity are two important factors affecting vision-related quality of life in advanced age-related macular degeneration.

    Science.gov (United States)

    Roh, Miin; Selivanova, Alexandra; Shin, Hyun Joon; Miller, Joan W; Jackson, Mary Lou

    2018-01-01

    Vision loss from age-related macular degeneration (AMD) has a profound effect on vision-related quality of life (VRQoL). The pupose of this study is to identify clinical factors associated with VRQoL using the Rasch- calibrated NEI VFQ-25 scales in bilateral advanced AMD patients. We retrospectively reviewed 47 patients (mean age 83.2 years) with bilateral advanced AMD. Clinical assessment included age, gender, type of AMD, high contrast visual acuity (VA), history of medical conditions, contrast sensitivity (CS), central visual field loss, report of Charles Bonnet Syndrome, current treatment for AMD and Rasch-calibrated NEI VFQ-25 visual function and socioemotional function scales. The NEI VFQ visual function scale includes items of general vision, peripheral vision, distance vision and near vision-related activity while the socioemotional function scale includes items of vision related-social functioning, role difficulties, dependency, and mental health. Multiple regression analysis (structural regression model) was performed using fixed item parameters obtained from the one-parameter item response theory model. Multivariate analysis showed that high contrast VA and CS were two factors influencing VRQoL visual function scale (β = -0.25, 95% CI-0.37 to -0.12, p<0.001 and β = 0.35, 95% CI 0.25 to 0.46, p<0.001) and socioemontional functioning scale (β = -0.2, 95% CI -0.37 to -0.03, p = 0.023, and β = 0.3, 95% CI 0.18 to 0.43, p = 0.001). Central visual field loss was not assoicated with either VRQoL visual or socioemontional functioning scale (β = -0.08, 95% CI-0.28 to 0.12,p = 0.44 and β = -0.09, 95% CI -0.03 to 0.16, p = 0.50, respectively). In patients with vision impairment secondary to bilateral advanced AMD, high contrast VA and CS are two important factors affecting VRQoL.

  16. Efficacy of vision therapy in children with learning disability and associated binocular vision anomalies.

    Science.gov (United States)

    Hussaindeen, Jameel Rizwana; Shah, Prerana; Ramani, Krishna Kumar; Ramanujan, Lalitha

    To report the frequency of binocular vision (BV) anomalies in children with specific learning disorders (SLD) and to assess the efficacy of vision therapy (VT) in children with a non-strabismic binocular vision anomaly (NSBVA). The study was carried out at a centre for learning disability (LD). Comprehensive eye examination and binocular vision assessment was carried out for 94 children (mean (SD) age: 15 (2.2) years) diagnosed with specific learning disorder. BV assessment was done for children with best corrected visual acuity of ≥6/9 - N6, cooperative for examination and free from any ocular pathology. For children with a diagnosis of NSBVA (n=46), 24 children were randomized to VT and no intervention was provided to the other 22 children who served as experimental controls. At the end of 10 sessions of vision therapy, BV assessment was performed for both the intervention and non-intervention groups. Binocular vision anomalies were found in 59 children (62.8%) among which 22% (n=13) had strabismic binocular vision anomalies (SBVA) and 78% (n=46) had a NSBVA. Accommodative infacility (AIF) was the commonest of the NSBVA and found in 67%, followed by convergence insufficiency (CI) in 25%. Post-vision therapy, the intervention group showed significant improvement in all the BV parameters (Wilcoxon signed rank test, p<0.05) except negative fusional vergence. Children with specific learning disorders have a high frequency of binocular vision disorders and vision therapy plays a significant role in improving the BV parameters. Children with SLD should be screened for BV anomalies as it could potentially be an added hindrance to the reading difficulty in this special population. Copyright © 2017 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.

  17. Conceptual analysis of Physiology of vision in Ayurveda

    Directory of Open Access Journals (Sweden)

    Praveen Balakrishnan

    2014-01-01

    Full Text Available The process by which the world outside is seen is termed as visual process or physiology of vision. There are three phases in this visual process: phase of refraction of light, phase of conversion of light energy into electrical impulse and finally peripheral and central neurophysiology. With the advent of modern instruments step by step biochemical changes occurring at each level of the visual process has been deciphered. Many investigations have emerged to track these changes and helping to diagnose the exact nature of the disease. Ayurveda has described this physiology of vision based on the functions of vata and pitta. Philosophical textbook of ayurveda, Tarka Sangraha, gives certain basics facts of visual process. This article discusses the second and third phase of visual process. Step by step analysis of the visual process through the spectacles of ayurveda amalgamated with the basics of philosophy from Tarka Sangraha has been analyzed critically to generate a concrete idea regarding the physiology and hence thereby interpret the pathology on the grounds of ayurveda based on the investigative reports.

  18. Empirical evaluation methods in computer vision

    CERN Document Server

    Christensen, Henrik I

    2002-01-01

    This book provides comprehensive coverage of methods for the empirical evaluation of computer vision techniques. The practical use of computer vision requires empirical evaluation to ensure that the overall system has a guaranteed performance. The book contains articles that cover the design of experiments for evaluation, range image segmentation, the evaluation of face recognition and diffusion methods, image matching using correlation methods, and the performance of medical image processing algorithms. Sample Chapter(s). Foreword (228 KB). Chapter 1: Introduction (505 KB). Contents: Automate

  19. Peripheral ulcerative keratitis associated with chronic malabsorption syndrome and miliary tuberculosis in a child

    Directory of Open Access Journals (Sweden)

    Tarun Arora

    2015-01-01

    Full Text Available A 16-year-old girl presented with pain, redness, watering, and blurring of vision in her right eye. Slit lamp examination revealed the presence of peripheral ulcerative keratitis (PUK and nodular scleritis. On clinical examination, the patient had stunted growth, low body mass index, and enlarged axillary nodes. Giardia cysts were present in the stool sample and histopathology of axillary lymph nodes showed caseating necrosis suggestive of tuberculosis (TB. A diagnosis of PUK with chronic malabsorption syndrome secondary to giardiasis and miliary TB was made. Oral metronidazole, anti-tubercular treatment, high protein diet and vitamin supplements were started. Topical steroids were started for peripheral ulcerative lesions following, which the PUK resolved.

  20. Phases of daylight and the stability of color perception in the near peripheral human retina.

    Science.gov (United States)

    Panorgias, Athanasios; Kulikowski, Janus J; Parry, Neil R A; McKeefry, Declan J; Murray, Ian J

    2012-03-01

    Typical daylight extends from blue (morning sky) to orangey red (evening sky) and is represented mathematically as the Daylight Locus in color space. In this study, we investigate the impact of this daylight variation on human color vision. Thirty-eight color normal human observers performed an asymmetric color match in the near peripheral visual field. Unique hues were identified using a naming paradigm. The observers' performance for matching was almost perfectly coincident with the Daylight Locus but declined markedly in other regions. Interobserver variability reached a conspicuous minimum adjacent to the Daylight Locus and was maximal in the red and yellowish-green regions. In the naming task, unique blue and yellow were virtually coincident with the Daylight Locus. The results suggest that the mechanisms of color perception mediated by the phylogenetically older (blue-yellow) color pathway have been strongly influenced by the different phases of daylight.

  1. Computer vision as an alternative for collision detection

    OpenAIRE

    Drangsholt, Marius Aarvik

    2015-01-01

    The goal of this thesis was to implement a computer vision system on a low power platform, to see if that could be an alternative for a collision detection system. To achieve this, research into fundamentals in computer vision were performed, and both hardware and software implementation were carried out. To create the computer vision system, a stereo rig were constructed using low cost Logitech webcameras, and connected to a Raspberry Pi 2 development board. The computer vision library Op...

  2. FLORA™: Phase I development of a functional vision assessment for prosthetic vision users.

    Science.gov (United States)

    Geruschat, Duane R; Flax, Marshall; Tanna, Nilima; Bianchi, Michelle; Fisher, Andy; Goldschmidt, Mira; Fisher, Lynne; Dagnelie, Gislin; Deremeik, Jim; Smith, Audrey; Anaflous, Fatima; Dorn, Jessy

    2015-07-01

    Research groups and funding agencies need a functional assessment suitable for an ultra-low vision population to evaluate the impact of new vision-restoration treatments. The purpose of this study was to develop a pilot assessment to capture the functional visual ability and well-being of subjects whose vision has been partially restored with the Argus II Retinal Prosthesis System. The Functional Low-Vision Observer Rated Assessment (FLORA) pilot assessment involved a self-report section, a list of functional visual tasks for observation of performance and a case narrative summary. Results were analysed to determine whether the interview questions and functional visual tasks were appropriate for this ultra-low vision population and whether the ratings suffered from floor or ceiling effects. Thirty subjects with severe to profound retinitis pigmentosa (bare light perception or worse in both eyes) were enrolled in a clinical trial and implanted with the Argus II System. From this population, 26 subjects were assessed with the FLORA. Seven different evaluators administered the assessment. All 14 interview questions were asked. All 35 tasks for functional vision were selected for evaluation at least once, with an average of 20 subjects being evaluated for each test item. All four rating options—impossible (33 per cent), difficult (23 per cent), moderate (24 per cent) and easy (19 per cent)—were used by the evaluators. Evaluators also judged the amount of vision they observed the subjects using to complete the various tasks, with 'vision only' occurring 75 per cent on average with the System ON, and 29 per cent with the System OFF. The first version of the FLORA was found to contain useful elements for evaluation and to avoid floor and ceiling effects. The next phase of development will be to refine the assessment and to establish reliability and validity to increase its value as an assessment tool for functional vision and well-being. © 2015 The Authors. Clinical

  3. Operational Based Vision Assessment Automated Vision Test Collection User Guide

    Science.gov (United States)

    2017-05-15

    AFRL-SA-WP-SR-2017-0012 Operational Based Vision Assessment Automated Vision Test Collection User Guide Elizabeth Shoda, Alex...June 2015 – May 2017 4. TITLE AND SUBTITLE Operational Based Vision Assessment Automated Vision Test Collection User Guide 5a. CONTRACT NUMBER... automated vision tests , or AVT. Development of the AVT was required to support threshold-level vision testing capability needed to investigate the

  4. Virtual bronchoscopy-guided transbronchial biopsy for aiding the diagnosis of peripheral lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Iwano, Shingo, E-mail: iwano45@med.nagoya-u.ac.jp [Department of Radiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Shouwa-ku, Nagoya 4668550, Aichi (Japan); Imaizumi, Kazuyoshi [Department of Respiratory Medicine, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Shouwa-ku, Nagoya 4668550 (Japan); Okada, Tohru [Research Center for Charged Particle Therapy, National Institute of Radiological Science, 4-9-1 Anagawa, Inage-ku, Chiba 2638555 (Japan); Hasegawa, Yoshinori [Department of Respiratory Medicine, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Shouwa-ku, Nagoya 4668550 (Japan); Naganawa, Shinji [Department of Radiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Shouwa-ku, Nagoya 4668550, Aichi (Japan)

    2011-07-15

    Objective: The aim of this study was to evaluate the clinical value of virtual bronchoscopy (VB) in aiding diagnosis of peripheral lung cancer by transbronchial biopsy (TBB). In addition, we sought to systematically analyze the factors that affect the diagnostic sensitivity of VB-guided TBB for the evaluation of peripheral lung cancers. Materials and methods: A hundred and twenty-two peripheral lung cancers from 122 patients (82 men and 40 women, 38-84 years; median 68.5 years) who were performed VB-guided TBB were evaluated retrospectively. VB was reconstructed from 1- or 0.5-mm slice thickness images of multi-detector CT (MDCT). Experienced pulmonologists inserted the conventional and ultrathin bronchoscopes into the target bronchus under direct vision following the VB image. Results: A definitive diagnosis was established by VB-guided TBB in 96 lesions (79%). The diagnostic sensitivity of small pulmonary lesions {<=}30 mm in maximal diameter (71%) was significantly lower than that of lesions >30 mm (91%, p = 0.008). For small pulmonary lesions {<=}30 mm (n = 76), internal opacity of the lesion was the independent predictor of diagnostic sensitivity by VB-guided TBB, and the non-solid type lung cancers were significantly lower than the solid type and part-solid type lung cancers for diagnostic sensitivity (odds ratio = 0.161; 95% confidence interval = 0.033-0.780; p = 0.023). Conclusion: Use of an ultrathin bronchoscope and simulation with VB reconstructed by high quality MDCT images is thought to improve pathological diagnosis of peripheral lung cancers, especially for solid and partly solid types. For small pulmonary lesions {<=}30 mm, the lesion internal opacity is a significant factor for predicting the diagnostic sensitivity, and the sensitivity was low for small non-solid type of lung cancers.

  5. Quantitative evaluation of vision-related and health-related quality of life after endoscopic transsphenoidal surgery for pituitary adenoma.

    Science.gov (United States)

    Wolf, Amparo; Coros, Alexandra; Bierer, Joel; Goncalves, Sandy; Cooper, Paul; Van Uum, Stan; Lee, Donald H; Proulx, Alain; Nicolle, David; Fraser, J Alexander; Rotenberg, Brian W; Duggal, Neil

    2017-08-01

    OBJECTIVE Endoscopic resection of pituitary adenomas has been reported to improve vision function in up to 80%-90% of patients with visual impairment due to these adenomas. It is unclear how these reported rates translate into improvement in visual outcomes and general health as perceived by the patients. The authors evaluated self-assessed health-related quality of life (HR-QOL) and vision-related QOL (VR-QOL) in patients before and after endoscopic resection of pituitary adenomas. METHODS The authors prospectively collected data from 50 patients who underwent endoscopic resection of pituitary adenomas. This cohort included 32 patients (64%) with visual impairment preoperatively. Twenty-seven patients (54%) had pituitary dysfunction, including 17 (34%) with hormone-producing tumors. Patients completed the National Eye Institute Visual Functioning Questionnaire and the 36-Item Short Form Health Survey preoperatively and 6 weeks and 6 months after surgery. RESULTS Patients with preoperative visual impairment reported a significant impact of this condition on VR-QOL preoperatively, including general vision, near activities, and peripheral vision; they also noted vision-specific impacts on mental health, role difficulties, dependency, and driving. After endoscopic resection of adenomas, patients reported improvement across all these categories 6 weeks postoperatively, and this improvement was maintained by 6 months postoperatively. Patients with preoperative pituitary dysfunction, including hormone-producing tumors, perceived their general health and physical function as poorer, with some of these patients reporting improvement in perceived general health after the endoscopic surgery. All patients noted that their ability to work or perform activities of daily living was transiently reduced 6 weeks postoperatively, followed by significant improvement by 6 months after the surgery. CONCLUSIONS Both VR-QOL and patient's perceptions of their ability to do work and

  6. Predictors of vision impairment in Multiple Sclerosis.

    Science.gov (United States)

    Sanchez-Dalmau, Bernardo; Martinez-Lapiscina, Elena H; Pulido-Valdeolivas, Irene; Zubizarreta, Irati; Llufriu, Sara; Blanco, Yolanda; Sola-Valls, Nuria; Sepulveda, Maria; Guerrero, Ana; Alba, Salut; Andorra, Magi; Camos, Anna; Sanchez-Vela, Laura; Alfonso, Veronica; Saiz, Albert; Villoslada, Pablo

    2018-01-01

    Visual impairment significantly alters the quality of life of people with Multiple Sclerosis (MS). The objective of this study was to identify predictors (independent variables) of visual outcomes, and to define their relationship with neurological disability and retinal atrophy when assessed by optical coherence tomography (OCT). We performed a cross-sectional analysis of 119 consecutive patients with MS, assessing vision using high contrast visual acuity (LogMar), 2.5% and 1.25% low contrast visual acuity (Sloan charts), and color vision (Hardy-Rand-Rittler plates). Quality of vision is a patient reported outcome based on an individual's unique perception of his or her vision and was assessed with the Visual Functioning Questionnaire-25 (VFQ-25) with the 10 neuro-ophthalmologic items. MS disability was assessed using the expanded disability status scale (EDSS), the MS functional composite (MSFC) and the brief repetitive battery-neuropsychology (BRB-N). Retinal atrophy was assessed using spectral domain OCT, measuring the thickness of the peripapillar retinal nerve fiber layer (pRNFL) and the volume of the ganglion cell plus inner plexiform layer (GCIPL). The vision of patients with MS was impaired, particularly in eyes with prior optic neuritis. Retinal atrophy (pRNFL and GCIPL) was closely associated with impaired low contrast vision and color vision, whereas the volume of the GCIPL showed a trend (p = 0.092) to be associated with quality of vision. Multiple regression analysis revealed that EDSS was an explanatory variable for high contrast vision after stepwise analysis, GCIPL volume for low contrast vision, and GCIPL volume and EDSS for color vision. The explanatory variables for quality of vision were high contrast vision and color vision. In summary, quality of vision in MS depends on the impairment of high contrast visual acuity and color vision due to the disease.

  7. Intraoperative Ultrasound for Peripheral Nerve Applications.

    Science.gov (United States)

    Willsey, Matthew; Wilson, Thomas J; Henning, Phillip Troy; Yang, Lynda J-S

    2017-10-01

    Offering real-time, high-resolution images via intraoperative ultrasound is advantageous for a variety of peripheral nerve applications. To highlight the advantages of ultrasound, its extraoperative uses are reviewed. The current intraoperative uses, including nerve localization, real-time evaluation of peripheral nerve tumors, and implantation of leads for peripheral nerve stimulation, are reviewed. Although intraoperative peripheral nerve localization has been performed previously using guide wires and surgical dyes, the authors' approach using ultrasound-guided instrument clamps helps guide surgical dissection to the target nerve, which could lead to more timely operations and shorter incisions. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Effectiveness of Assistive Technologies for Low Vision Rehabilitation: A Systematic Review

    Science.gov (United States)

    Jutai, Jeffrey W.; Strong, J. Graham; Russell-Minda, Elizabeth

    2009-01-01

    "Low vision" describes any condition of diminished vision that is uncorrectable by standard eyeglasses, contact lenses, medication, or surgery that disrupts a person's ability to perform common age-appropriate visual tasks. Examples of assistive technologies for vision rehabilitation include handheld magnifiers; electronic vision-enhancement…

  9. [Atherectomy for peripheral arterial disease].

    Science.gov (United States)

    Londero, Louise Skovgaard; Høgh, Annette Langager; Lindholt, Jes Sanddal

    2015-04-13

    Symptomatic peripheral arterial disease is managed according to national and international guidelines and the number of vascular reconstructions performed each year has increased over the past decade mainly due to an increasing frequency of endovascular procedures. Atherectomy as an alternative to the established treatment of symptomatic peripheral arterial disease has recently been analysed in a Cochrane review. In Denmark, atherectomy is not performed and so far the evidence is poor as the method is not an alternative to the established treatment in this country.

  10. Development of Non-contact Respiratory Monitoring System for Newborn Using a FG Vision Sensor

    Science.gov (United States)

    Kurami, Yoshiyuki; Itoh, Yushi; Natori, Michiya; Ohzeki, Kazuo; Aoki, Yoshimitsu

    In recent years, development of neonatal care is strongly hoped, with increase of the low-birth-weight baby birth rate. Especially respiration of low-birth-weight baby is incertitude because central nerve and respiratory function is immature. Therefore, a low-birth-weight baby often causes a disease of respiration. In a NICU (Neonatal Intensive Care Unit), neonatal respiration is monitored using cardio-respiratory monitor and pulse oximeter at all times. These contact-type sensors can measure respiratory rate and SpO2 (Saturation of Peripheral Oxygen). However, because a contact-type sensor might damage the newborn's skin, it is a real burden to monitor neonatal respiration. Therefore, we developed the respiratory monitoring system for newborn using a FG (Fiber Grating) vision sensor. FG vision sensor is an active stereo vision sensor, it is possible for non-contact 3D measurement. A respiratory waveform is calculated by detecting the vertical motion of the thoracic and abdominal region with respiration. We attempted clinical experiment in the NICU, and confirmed the accuracy of the obtained respiratory waveform was high. Non-contact respiratory monitoring of newborn using a FG vision sensor enabled the minimally invasive procedure.

  11. Investigating Teachers' Personal Visions and Beliefs: Implications ...

    African Journals Online (AJOL)

    Investigating Teachers' Personal Visions and Beliefs: Implications for Quality in Language Teacher Education. ... attitude, focus and performance. The growing influence of constructivism in teacher education and the increase in the amount of research into teacher cognition has put the notion of beliefs and vision into central ...

  12. Peripherally applied opioids for postoperative pain

    DEFF Research Database (Denmark)

    Nielsen, B N; Henneberg, S W; Schmiegelow, K

    2015-01-01

    BACKGROUND: Opioids applied peripherally at the site of surgery may produce postoperative analgesia with few side effects. We performed this systematic review to evaluate the analgesic effect of peripherally applied opioids for acute postoperative pain. METHODS: We searched PubMed (1966 to June...... 2013), Embase (1980 to June 2013), and the Cochrane Central Register of Controlled Trials (The Cochrane Library 2013, Issue 6). Randomized controlled trials investigating the postoperative analgesic effect of peripherally applied opioids vs. systemic opioids or placebo, measured by pain intensity...... difference -5 mm, 95% CI: -7 to -3) for peripherally applied opioids vs. placebo and statistically significant increased time to first analgesic (mean difference 153 min, 95% CI: 41-265). When preoperative inflammation was reported (five studies), peripherally applied opioids significantly improved...

  13. Vision in water.

    Science.gov (United States)

    Atchison, David A; Valentine, Emma L; Gibson, Georgina; Thomas, Hannah R; Oh, Sera; Pyo, Young Ah; Lacherez, Philippe; Mathur, Ankit

    2013-09-06

    The purpose of this study is to determine visual performance in water, including the influence of pupil size. The water environment was simulated by placing goggles filled with saline in front of the eyes with apertures placed at the front of the goggles. Correction factors were determined for the different magnification under this condition in order to estimate vision in water. Experiments were conducted on letter visual acuity (seven participants), grating resolution (eight participants), and grating contrast sensitivity (one participant). For letter acuity, mean loss of vision in water, compared to corrected vision in air, varied between 1.1 log min of arc resolution (logMAR) for a 1 mm aperture to 2.2 logMAR for a 7 mm aperture. The vision in min of arc was described well by a linear relationship with pupil size. For grating acuity, mean loss varied between 1.1 logMAR for a 2 mm aperture to 1.2 logMAR for a 6 mm aperture. Contrast sensitivity for a 2 mm aperture deteriorated as spatial frequency increased with a 2 log unit loss by 3 c/°. Superimposed on this deterioration were depressions (notches) in sensitivity with the first three notches occurring at 0.45, 0.8, and 1.3 c/° with estimates for water of 0.39, 0.70, and 1.13 c/°. In conclusion, vision in water is poor. It becomes worse as pupil size increases, but the effects are much more marked for letter targets than for grating targets.

  14. Development of a battery of functional tests for low vision.

    Science.gov (United States)

    Dougherty, Bradley E; Martin, Scott R; Kelly, Corey B; Jones, Lisa A; Raasch, Thomas W; Bullimore, Mark A

    2009-08-01

    We describe the development and evaluation of a battery of tests of functional visual performance of everyday tasks intended to be suitable for assessment of low vision patients. The functional test battery comprises-Reading rate: reading aloud 20 unrelated words for each of four print sizes (8, 4, 2, & 1 M); Telephone book: finding a name and reading the telephone number; Medicine bottle label: reading the name and dosing; Utility bill: reading the due date and amount due; Cooking instructions: reading cooking time on a food package; Coin sorting: making a specified amount from coins placed on a table; Playing card recognition: identifying denomination and suit; and Face recognition: identifying expressions of printed, life-size faces at 1 and 3 m. All tests were timed except face and playing card recognition. Fourteen normally sighted and 24 low vision subjects were assessed with the functional test battery. Visual acuity, contrast sensitivity, and quality of life (National Eye Institute Visual Function Questionnaire 25 [NEI-VFQ 25]) were measured and the functional tests repeated. Subsequently, 23 low vision patients participated in a pilot randomized clinical trial with half receiving low vision rehabilitation and half a delayed intervention. The functional tests were administered at enrollment and 3 months later. Normally sighted subjects could perform all tasks but the proportion of trials performed correctly by the low vision subjects ranged from 35% for face recognition at 3 m, to 95% for the playing card identification. On average, low vision subjects performed three times slower than the normally sighted subjects. Timed tasks with a visual search component showed poorer repeatability. In the pilot clinical trial, low vision rehabilitation produced the greatest improvement for the medicine bottle and cooking instruction tasks. Performance of patients on these functional tests has been assessed. Some appear responsive to low vision rehabilitation.

  15. Peripheral venous catheter insertion simulation training: A randomized controlled trial comparing performance after instructor-led teaching versus peer-assisted learning.

    Science.gov (United States)

    Pelloux, Sophie; Grégoire, Arnaud; Kirmizigul, Patrice; Maillot, Sandrine; Bui-Xuan, Bernard; Llorca, Guy; Boet, Sylvain; Lehot, Jean-Jacques; Rimmelé, Thomas

    2017-12-01

    Peripheral venous catheter insertion is a procedural skill that every medical student should master. Training is often limited to a small number of students and is poorly evaluated. The objective of this study was to evaluate the performance of peer-assisted learning in comparison to instructor-led teaching for peripheral venous catheter insertion training. Students were randomized to the control group attending a traditional instructor-led training session (slideshow and demonstration by an anesthetist instructor, followed by training on a procedural simulator) or to the test group attending a peer-assisted training session (slideshow and demonstration video-recorded by the same instructor, followed by training on a procedural simulator). The primary endpoint was the performance of peripheral venous catheter insertion, assessed on procedural simulator one week later by blinded experts using a standardized 20-item grid. Students self-evaluated their confidence levels using a numeric 10-point scale. Eighty-six students were included, 73 of whom attended the assessment session. The median performance score was 12/20 [8-15] in the instructor-led teaching group versus 13/20 [11-15] in the peer-assisted learning group (P=0.430). Confidence levels improved significantly after the assessment session and were significantly higher in the peer-assisted learning group (7.6/10 [7.0-8.0] versus 7.0/10 [5.0-8.0], P=0.026). Peer-assisted learning is effective for peripheral venous catheter insertion training and can be as effective as instructor-led teaching. Given the large number of students to train, this finding is important for optimizing the cost-effectiveness of peripheral venous catheter insertion training. Copyright © 2017 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  16. Angioplasty and stent placement - peripheral arteries - discharge

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000234.htm Angioplasty and stent placement - peripheral arteries - discharge To use the sharing ... peripheral artery). You may have also had a stent placed. To perform the procedure: Your doctor inserted ...

  17. Vision in high-level football officials.

    Directory of Open Access Journals (Sweden)

    António Manuel Gonçalves Baptista

    Full Text Available Officiating in football depends, at least to some extent, upon adequate visual function. However, there is no vision standard for football officiating and the nature of the relationship between officiating performance and level of vision is unknown. As a first step in characterising this relationship, we report on the clinically-measured vision and on the perceived level of vision in elite-level, Portuguese football officials. Seventy-one referees (R and assistant referees (AR participated in the study, representing 92% of the total population of elite level football officials in Portugal in the 2013/2014 season. Nine of the 22 Rs (40.9% and ten of the 49 ARs (20.4% were international-level. Information about visual history was also gathered. Perceived vision was assessed using the preference-values-assigned-to-global-visual-status (PVVS and the Quality-of-Vision (QoV questionnaire. Standard clinical vision measures (including visual acuity, contrast sensitivity and stereopsis were gathered in a subset (n = 44, 62% of the participants. Data were analysed according to the type (R/AR and level (international/national of official, and Bonferroni corrections were applied to reduce the risk of type I errors. Adopting criterion for statistical significance of p<0.01, PVVS scores did not differ between R and AR (p = 0.88, or between national- and international-level officials (p = 0.66. Similarly, QoV scores did not differ between R and AR in frequency (p = 0.50, severity (p = 0.71 or bothersomeness (p = 0.81 of symptoms, or between international-level vs national-level officials for frequency (p = 0.03 or bothersomeness (p = 0.07 of symptoms. However, international-level officials reported less severe symptoms than their national-level counterparts (p<0.01. Overall, 18.3% of officials had either never had an eye examination or if they had, it was more than 3 years previously. Regarding refractive correction, 4.2% had undergone refractive surgery and

  18. Pediatric Low Vision

    Science.gov (United States)

    ... Asked Questions Español Condiciones Chinese Conditions Pediatric Low Vision What is Low Vision? Partial vision loss that cannot be corrected causes ... and play. What are the signs of Low Vision? Some signs of low vision include difficulty recognizing ...

  19. Prevalence of color vision deficiency among arc welders.

    Science.gov (United States)

    Heydarian, Samira; Mahjoob, Monireh; Gholami, Ahmad; Veysi, Sajjad; Mohammadi, Morteza

    This study was performed to investigate whether occupationally related color vision deficiency can occur from welding. A total of 50 male welders, who had been working as welders for at least 4 years, were randomly selected as case group, and 50 age matched non-welder men, who lived in the same area, were regarded as control group. Color vision was assessed using the Lanthony desatured panel D-15 test. The test was performed under the daylight fluorescent lamp with a spectral distribution of energy with a color temperature of 6500K and a color rendering index of 94 that provided 1000lx on the work plane. The test was carried out monocularly and no time limit was imposed. All data analysis were performed using SPSS, version 22. The prevalence of dyschromatopsia among welders was 15% which was statistically higher than that of nonwelder group (2%) (p=0.001). Among welders with dyschromatopsia, color vision deficiency in 72.7% of cases was monocular. There was positive relationship between the employment length and color vision loss (p=0.04). Similarly, a significant correlation was found between the prevalence of color vision deficiency and average working hours of welding a day (p=0.025). Chronic exposure to welding light may cause color vision deficiency. The damage depends on the exposure duration and the length of their employment as welders. Copyright © 2016 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.

  20. Low vision and mobility scooters: the experiences of individuals with low vision who use mobility scooters.

    Science.gov (United States)

    McMullan, Keri S; Butler, Mary

    2018-05-09

    Older adults with low vision are a growing population with rehabilitation needs including support with community mobility to enable community participation. Some older adults with low vision choose to use mobility scooters to mobilize within their community, but there is limited research about the use by people with low vision. This paper describes a pilot study and asks the question: what are the experiences of persons with low vision who use mobility scooters? This study gathered the experiences of four participants with low vision, aged 51 and over, who regularly use mobility scooters. Diverse methods were used including a go-along, a semi-structured interview and a new measure of functional vision for mobility called the vision-related outcomes in orientation and mobility (VROOM). Four themes were found to describe experiences: autonomy and well-being, accessibility, community interactions and self-regulation. Discussion and implications: This study was a pilot for a larger study examining self-regulation in scooter users. However, as roles emerge for health professionals and scooters, the findings also provide evidence to inform practice, because it demonstrates the complex meaning and influences on performance involved in low vision mobility scooter use. Implications for rehabilitation Scooter use supports autonomy and well-being and community connections for individuals with both mobility and visual impairments. Low vision scooter users demonstrate self-regulation of their scooter use to manage both their visual and environmental limitations. Issues of accessibility experienced by this sample affect a wider community of footpath users, emphasizing the need for councils to address inadequate infrastructure. Rehabilitators can support their low vision clients' scooter use by acknowledging issues of accessibility and promoting self-regulation strategies to manage risks and barriers.

  1. The risk of pedestrian collisions with peripheral visual field loss.

    Science.gov (United States)

    Peli, Eli; Apfelbaum, Henry; Berson, Eliot L; Goldstein, Robert B

    2016-12-01

    Patients with peripheral field loss complain of colliding with other pedestrians in open-space environments such as shopping malls. Field expansion devices (e.g., prisms) can create artificial peripheral islands of vision. We investigated the visual angle at which these islands can be most effective for avoiding pedestrian collisions, by modeling the collision risk density as a function of bearing angle of pedestrians relative to the patient. Pedestrians at all possible locations were assumed to be moving in all directions with equal probability within a reasonable range of walking speeds. The risk density was found to be highly anisotropic. It peaked at ≈45° eccentricity. Increasing pedestrian speed range shifted the risk to higher eccentricities. The risk density is independent of time to collision. The model results were compared to the binocular residual peripheral island locations of 42 patients with forms of retinitis pigmentosa. The natural residual island prevalence also peaked nasally at about 45° but temporally at about 75°. This asymmetry resulted in a complementary coverage of the binocular field of view. Natural residual binocular island eccentricities seem well matched to the collision-risk density function, optimizing detection of other walking pedestrians (nasally) and of faster hazards (temporally). Field expansion prism devices will be most effective if they can create artificial peripheral islands at about 45° eccentricities. The collision risk and residual island findings raise interesting questions about normal visual development.

  2. Use of an augmented-vision device for visual search by patients with tunnel vision.

    Science.gov (United States)

    Luo, Gang; Peli, Eli

    2006-09-01

    To study the effect of an augmented-vision device that superimposes minified contour images over natural vision on visual search performance of patients with tunnel vision. Twelve subjects with tunnel vision searched for targets presented outside their visual fields (VFs) on a blank background under three cue conditions (with contour cues provided by the device, with auditory cues, and without cues). Three subjects (VF, 8 degrees -11 degrees wide) carried out the search over a 90 degrees x 74 degrees area, and nine subjects (VF, 7 degrees -16 degrees wide) carried out the search over a 66 degrees x 52 degrees area. Eye and head movements were recorded for performance analyses that included directness of search path, search time, and gaze speed. Directness of the search path was greatly and significantly improved when the contour or auditory cues were provided in the larger and the smaller area searches. When using the device, a significant reduction in search time (28% approximately 74%) was demonstrated by all three subjects in the larger area search and by subjects with VFs wider than 10 degrees in the smaller area search (average, 22%). Directness and gaze speed accounted for 90% of the variability of search time. Although performance improvement with the device for the larger search area was obvious, whether it was helpful for the smaller search area depended on VF and gaze speed. Because improvement in directness was demonstrated, increased gaze speed, which could result from further training and adaptation to the device, might enable patients with small VFs to benefit from the device for visual search tasks.

  3. NETRA: A parallel architecture for integrated vision systems 2: Algorithms and performance evaluation

    Science.gov (United States)

    Choudhary, Alok N.; Patel, Janak H.; Ahuja, Narendra

    1989-01-01

    In part 1 architecture of NETRA is presented. A performance evaluation of NETRA using several common vision algorithms is also presented. Performance of algorithms when they are mapped on one cluster is described. It is shown that SIMD, MIMD, and systolic algorithms can be easily mapped onto processor clusters, and almost linear speedups are possible. For some algorithms, analytical performance results are compared with implementation performance results. It is observed that the analysis is very accurate. Performance analysis of parallel algorithms when mapped across clusters is presented. Mappings across clusters illustrate the importance and use of shared as well as distributed memory in achieving high performance. The parameters for evaluation are derived from the characteristics of the parallel algorithms, and these parameters are used to evaluate the alternative communication strategies in NETRA. Furthermore, the effect of communication interference from other processors in the system on the execution of an algorithm is studied. Using the analysis, performance of many algorithms with different characteristics is presented. It is observed that if communication speeds are matched with the computation speeds, good speedups are possible when algorithms are mapped across clusters.

  4. Improved reading performance using individualized compensation filters for observers with losses in central vision

    Science.gov (United States)

    Lawton, Teri B.

    1989-01-01

    A method to improve the reading performance of subjects with losses in central vision is proposed in which the amplitudes of the intermediate spatial frequencies are boosted relative to the lower spatial frequencies. In the method, words are filtered using an image enhancement function which is based on a subject's losses in visual function relative to a normal subject. It was found that 30-70 percent less magnification was necessary, and that reading rates were improved 2-3 times, using the method. The individualized compensation filters improved the clarity and visibility of words. The shape of the enhancement function was shown to be important in determining the optimum compensation filter for improving reading performance.

  5. Peripheral neuropathy

    Science.gov (United States)

    ... peripheral; Neuritis - peripheral; Nerve disease; Polyneuropathy; Chronic pain - peripheral neuropathy ... Philadelphia, PA: Elsevier; 2016:chap 107. Shy ME. Peripheral neuropathies. In: Goldman L, Schafer AI, eds. Goldman's Cecil ...

  6. Visual acuity and contrast sensitivity are two important factors affecting vision-related quality of life in advanced age-related macular degeneration

    Science.gov (United States)

    Selivanova, Alexandra; Shin, Hyun Joon; Miller, Joan W.; Jackson, Mary Lou

    2018-01-01

    Purpose Vision loss from age-related macular degeneration (AMD) has a profound effect on vision-related quality of life (VRQoL). The pupose of this study is to identify clinical factors associated with VRQoL using the Rasch- calibrated NEI VFQ-25 scales in bilateral advanced AMD patients. Methods We retrospectively reviewed 47 patients (mean age 83.2 years) with bilateral advanced AMD. Clinical assessment included age, gender, type of AMD, high contrast visual acuity (VA), history of medical conditions, contrast sensitivity (CS), central visual field loss, report of Charles Bonnet Syndrome, current treatment for AMD and Rasch-calibrated NEI VFQ-25 visual function and socioemotional function scales. The NEI VFQ visual function scale includes items of general vision, peripheral vision, distance vision and near vision-related activity while the socioemotional function scale includes items of vision related-social functioning, role difficulties, dependency, and mental health. Multiple regression analysis (structural regression model) was performed using fixed item parameters obtained from the one-parameter item response theory model. Results Multivariate analysis showed that high contrast VA and CS were two factors influencing VRQoL visual function scale (β = -0.25, 95% CI-0.37 to -0.12, p<0.001 and β = 0.35, 95% CI 0.25 to 0.46, p<0.001) and socioemontional functioning scale (β = -0.2, 95% CI -0.37 to -0.03, p = 0.023, and β = 0.3, 95% CI 0.18 to 0.43, p = 0.001). Central visual field loss was not assoicated with either VRQoL visual or socioemontional functioning scale (β = -0.08, 95% CI-0.28 to 0.12,p = 0.44 and β = -0.09, 95% CI -0.03 to 0.16, p = 0.50, respectively). Conclusion In patients with vision impairment secondary to bilateral advanced AMD, high contrast VA and CS are two important factors affecting VRQoL. PMID:29746512

  7. Burn-related peripheral neuropathy: A systematic review.

    Science.gov (United States)

    Tu, Yiji; Lineaweaver, William C; Zheng, Xianyou; Chen, Zenggan; Mullins, Fred; Zhang, Feng

    2017-06-01

    Peripheral neuropathy is the most frequent disabling neuromuscular complication of burns. However, the insidious and progressive onset of burn neuropathy makes it often undiagnosed or overlooked. In our study, we reviewed the current studies on the burn-related peripheral neuropathy to summarize the morbidity, mechanism, detecting method and management of peripheral neuropathy in burn patients. Of the 1533 burn patients included in our study, 98 cases (6.39%) were presented with peripheral neuropathy. Thermal and electrical burns were the most common etiologies. Surgical procedures, especially nerve decompression, showed good effect on functional recovery of both acute and delayed peripheral neuropathy in burn patients. It is noteworthy that, for early detection and prevention of peripheral neuropathy, electrodiagnostic examinations should be performed on burn patients independent of symptoms. Still, the underlying mechanisms of burn-related peripheral neuropathy remain to be clarified. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  8. KiWi Vision

    DEFF Research Database (Denmark)

    Schaffert, Sebastian; Bry, Francois; Dolog, Peter

    This deliverable describes the common vision of the KiWi project, ranging from motivation over use cases and usage scenarios to user interaction, system architecture and technologies, and the research that is performed as part of the project. The deliverable is intended for a wide audience to give...

  9. Patient-reported vision-related quality of life differences between superior and inferior hemifield visual field defects in primary open-angle glaucoma.

    Science.gov (United States)

    Cheng, Hui-Chen; Guo, Chao-Yu; Chen, Mei-Ju; Ko, Yu-Chieh; Huang, Nicole; Liu, Catherine Jui-ling

    2015-03-01

    Previous studies have found that glaucoma is associated with impaired patient-reported vision-related quality of life (pVRQOL) but few, to our knowledge, have assessed how the visual field (VF) defect location impacts the pVRQOL. To investigate the associations of VF defects in the superior vs inferior hemifields with pVRQOL outcomes in patients with primary open-angle glaucoma. Prospective cross-sectional study at a tertiary referral center from March 1, 2012, to January 1, 2013, including patients with primary open-angle glaucoma who had a best-corrected visual acuity in the better eye equal to or better than 20/60 and reliable VF tests. The pVRQOL was assessed by a validated Taiwanese version of the 25-item National Eye Institute Visual Function Questionnaire. Reliable VF tests obtained within 3 months of enrollment were transformed to binocular integrated VF (IVF). The IVF was further stratified by VF location (superior vs inferior hemifield). The association between each domain of the 25-item National Eye Institute Visual Function Questionnaire and superior or inferior hemifield IVF was determined using multivariable linear regression analysis. The analysis included 186 patients with primary open-angle glaucoma with a mean age of 59.1 years (range, 19-86 years) and IVF mean deviation (MD) of -4.84 dB (range, -27.56 to 2.17 dB). In the multivariable linear regression analysis, the MD of the full-field IVF showed positive associations with near activities (β = 0.05; R2 = 0.20; P < .001), vision-specific role difficulties (β = 0.04; R2 = 0.19; P = .01), vision-specific dependency (β = 0.04; R2 = 0.20; P < .001), driving (β = 0.05; R2 = 0.24; P < .001), peripheral vision (β = 0.03; R2 = 0.18; P = .02), and composite scores (β = 0.04; R2 = 0.27; P = .005). Subsequent analysis showed that the MD of the superior hemifield IVF was associated only with near activities (β = 0.04; R2

  10. Internet of Things and Artificial Vision, Performance and Applications: Literature Review

    Directory of Open Access Journals (Sweden)

    Vanessa Alvear-Puertas

    2017-02-01

    Full Text Available Internet of Things (or also known as IoT is one of the technologies most named today because of the ability it envisages to connect all kinds of devices to the Internet. If to the potentialities of IoT we add another technology of high impact as It is the Artificial Vision we have a wide field of innovative applications, where the processing of images and video in real time allow the visualization of large amounts of data on the Internet. The main applications developed with IoT and Artificial Vision can be implemented in education, medicine, intelligent buildings, surveillance systems of people and vehicles, among others. This type of applications improves the quality of life of users, however, for their development an infrastructure is required that allows the convergence of different protocols and devices, but in a special way that can handle the different phases of the acquisition of images. In this work, a review of the beginnings, concepts, technologies and applications related to the Artificial Vision with the Internet of Things has been carried out to be able to understand in a precise way the impact of its application in daily life.

  11. Peripheral refraction in normal infant rhesus monkeys

    Science.gov (United States)

    Hung, Li-Fang; Ramamirtham, Ramkumar; Huang, Juan; Qiao-Grider, Ying; Smith, Earl L.

    2008-01-01

    Purpose To characterize peripheral refractions in infant monkeys. Methods Cross-sectional data for horizontal refractions were obtained from 58 normal rhesus monkeys at 3 weeks of age. Longitudinal data were obtained for both the vertical and horizontal meridians from 17 monkeys. Refractive errors were measured by retinoscopy along the pupillary axis and at eccentricities of 15, 30, and 45 degrees. Axial dimensions and corneal power were measured by ultrasonography and keratometry, respectively. Results In infant monkeys, the degree of radial astigmatism increased symmetrically with eccentricity in all meridians. There were, however, initial nasal-temporal and superior-inferior asymmetries in the spherical-equivalent refractive errors. Specifically, the refractions in the temporal and superior fields were similar to the central ametropia, but the refractions in the nasal and inferior fields were more myopic than the central ametropia and the relative nasal field myopia increased with the degree of central hyperopia. With age, the degree of radial astigmatism decreased in all meridians and the refractions became more symmetrical along both the horizontal and vertical meridians; small degrees of relative myopia were evident in all fields. Conclusions As in adult humans, refractive error varied as a function of eccentricity in infant monkeys and the pattern of peripheral refraction varied with the central refractive error. With age, emmetropization occurred for both central and peripheral refractive errors resulting in similar refractions across the central 45 degrees of the visual field, which may reflect the actions of vision-dependent, growth-control mechanisms operating over a wide area of the posterior globe. PMID:18487366

  12. Dense range map reconstruction from a versatile robotic sensor system with an active trinocular vision and a passive binocular vision.

    Science.gov (United States)

    Kim, Min Young; Lee, Hyunkee; Cho, Hyungsuck

    2008-04-10

    One major research issue associated with 3D perception by robotic systems is the creation of efficient sensor systems that can generate dense range maps reliably. A visual sensor system for robotic applications is developed that is inherently equipped with two types of sensor, an active trinocular vision and a passive stereo vision. Unlike in conventional active vision systems that use a large number of images with variations of projected patterns for dense range map acquisition or from conventional passive vision systems that work well on specific environments with sufficient feature information, a cooperative bidirectional sensor fusion method for this visual sensor system enables us to acquire a reliable dense range map using active and passive information simultaneously. The fusion algorithms are composed of two parts, one in which the passive stereo vision helps active vision and the other in which the active trinocular vision helps the passive one. The first part matches the laser patterns in stereo laser images with the help of intensity images; the second part utilizes an information fusion technique using the dynamic programming method in which image regions between laser patterns are matched pixel-by-pixel with help of the fusion results obtained in the first part. To determine how the proposed sensor system and fusion algorithms can work in real applications, the sensor system is implemented on a robotic system, and the proposed algorithms are applied. A series of experimental tests is performed for a variety of configurations of robot and environments. The performance of the sensor system is discussed in detail.

  13. Grounding Our Vision: Brain Research and Strategic Vision

    Science.gov (United States)

    Walker, Mike

    2011-01-01

    While recognizing the value of "vision," it could be argued that vision alone--at least in schools--is not enough to rally the financial and emotional support required to translate an idea into reality. A compelling vision needs to reflect substantive, research-based knowledge if it is to spark the kind of strategic thinking and insight…

  14. Long term clinical outcome of peripheral nerve stimulation in patients with chronic peripheral neuropathic pain

    DEFF Research Database (Denmark)

    Calenbergh, F. Van; Gybels, J.; Laere, K. Van

    2009-01-01

    BACKGROUND: Chronic neuropathic pain after injury to a peripheral nerve is known to be resistant to treatment. Peripheral nerve stimulation is one of the possible treatment options, which is, however, not performed frequently. In recent years we have witnessed a renewed interest for PNS. The aim...... of the present study was to evaluate the long-term clinical efficacy of PNS in a group of patients with peripheral neuropathic pain treated with PNS since the 1980s. METHODS: Of an original series of 11 patients, 5 patients could be invited for clinical examination, detailed assessment of clinical pain and QST...... functioning) also showed positive effects. Quantitative Sensory Testing results did not show significant differences in cold pain and heat pain thresholds between the "ON" and "OFF" conditions. CONCLUSION: In selected patients with peripheral neuropathic pain PNS remains effective even after more than 20...

  15. Optoelectronic vision

    Science.gov (United States)

    Ren, Chunye; Parel, Jean-Marie A.

    1993-06-01

    Scientists have searched every discipline to find effective methods of treating blindness, such as using aids based on conversion of the optical image, to auditory or tactile stimuli. However, the limited performance of such equipment and difficulties in training patients have seriously hampered practical applications. A great edification has been given by the discovery of Foerster (1929) and Krause & Schum (1931), who found that the electrical stimulation of the visual cortex evokes the perception of a small spot of light called `phosphene' in both blind and sighted subjects. According to this principle, it is possible to invite artificial vision by using stimulation with electrodes placed on the vision neural system, thereby developing a prosthesis for the blind that might be of value in reading and mobility. In fact, a number of investigators have already exploited this phenomena to produce a functional visual prosthesis, bringing about great advances in this area.

  16. 78 FR 63302 - Qualification of Drivers; Exemption Applications; Vision

    Science.gov (United States)

    2013-10-23

    .... Ferris Mr. Ferris, 70, has had complete loss of vision in his right eye since 1991. The visual acuity in... sufficient vision to perform his driving tasks to operate a commercial vehicle.'' Mr. Ferris reported that he...

  17. The Distinct Role of the Amygdala, Superior Colliculus and Pulvinar in Processing of Central and Peripheral Snakes.

    Directory of Open Access Journals (Sweden)

    Inês Almeida

    Full Text Available Visual processing of ecologically relevant stimuli involves a central bias for stimuli demanding detailed processing (e.g., faces, whereas peripheral object processing is based on coarse identification. Fast detection of animal shapes holding a significant phylogenetic value, such as snakes, may benefit from peripheral vision. The amygdala together with the pulvinar and the superior colliculus are implicated in an ongoing debate regarding their role in automatic and deliberate spatial processing of threat signals.Here we tested twenty healthy participants in an fMRI task, and investigated the role of spatial demands (the main effect of central vs. peripheral vision in the processing of fear-relevant ecological features. We controlled for stimulus dependence using true or false snakes; snake shapes or snake faces and for task constraints (implicit or explicit. The main idea justifying this double task is that amygdala and superior colliculus are involved in both automatic and controlled processes. Moreover the explicit/implicit instruction in the task with respect to emotion is not necessarily equivalent to explicit vs. implicit in the sense of endogenous vs. exogenous attention, or controlled vs. automatic processes.We found that stimulus-driven processing led to increased amygdala responses specifically to true snake shapes presented in the centre or in the peripheral left hemifield (right hemisphere. Importantly, the superior colliculus showed significantly biased and explicit central responses to snake-related stimuli. Moreover, the pulvinar, which also contains foveal representations, also showed strong central responses, extending the results of a recent single cell pulvinar study in monkeys. Similar hemispheric specialization was found across structures: increased amygdala responses occurred to true snake shapes presented to the right hemisphere, with this pattern being closely followed by the superior colliculus and the pulvinar

  18. Project Magnify: Increasing Reading Skills in Students with Low Vision

    Science.gov (United States)

    Farmer, Jeanie; Morse, Stephen E.

    2007-01-01

    Modeled after Project PAVE (Corn et al., 2003) in Tennessee, Project Magnify is designed to test the idea that students with low vision who use individually prescribed magnification devices for reading will perform as well as or better than students with low vision who use large-print reading materials. Sixteen students with low vision were…

  19. A vision-based driver nighttime assistance and surveillance system based on intelligent image sensing techniques and a heterogamous dual-core embedded system architecture.

    Science.gov (United States)

    Chen, Yen-Lin; Chiang, Hsin-Han; Chiang, Chuan-Yen; Liu, Chuan-Ming; Yuan, Shyan-Ming; Wang, Jenq-Haur

    2012-01-01

    This study proposes a vision-based intelligent nighttime driver assistance and surveillance system (VIDASS system) implemented by a set of embedded software components and modules, and integrates these modules to accomplish a component-based system framework on an embedded heterogamous dual-core platform. Therefore, this study develops and implements computer vision and sensing techniques of nighttime vehicle detection, collision warning determination, and traffic event recording. The proposed system processes the road-scene frames in front of the host car captured from CCD sensors mounted on the host vehicle. These vision-based sensing and processing technologies are integrated and implemented on an ARM-DSP heterogamous dual-core embedded platform. Peripheral devices, including image grabbing devices, communication modules, and other in-vehicle control devices, are also integrated to form an in-vehicle-embedded vision-based nighttime driver assistance and surveillance system.

  20. Computational vision

    CERN Document Server

    Wechsler, Harry

    1990-01-01

    The book is suitable for advanced courses in computer vision and image processing. In addition to providing an overall view of computational vision, it contains extensive material on topics that are not usually covered in computer vision texts (including parallel distributed processing and neural networks) and considers many real applications.

  1. Making a vision document tangible using "vision-tactics-metrics" tables.

    Science.gov (United States)

    Drury, Ivo; Slomski, Carol

    2006-01-01

    We describe a method of making a vision document tangible by attaching specific tactics and metrics to the key elements of the vision. We report on the development and early use of a "vision-tactics-metrics" table in a department of surgery. Use of the table centered the vision in the daily life of the department and its faculty, and facilitated cultural change.

  2. Specifying colours for colour vision testing using computer graphics.

    Science.gov (United States)

    Toufeeq, A

    2004-10-01

    This paper describes a novel test of colour vision using a standard personal computer, which is simple and reliable to perform. Twenty healthy individuals with normal colour vision and 10 healthy individuals with a red/green colour defect were tested binocularly at 13 selected points in the CIE (Commission International d'Eclairage, 1931) chromaticity triangle, representing the gamut of a computer monitor, where the x, y coordinates of the primary colour phosphors were known. The mean results from individuals with normal colour vision were compared to those with defective colour vision. Of the 13 points tested, five demonstrated consistently high sensitivity in detecting colour defects. The test may provide a convenient method for classifying colour vision abnormalities.

  3. Perception of linear horizontal self-motion induced by peripheral vision /linearvection/ - Basic characteristics and visual-vestibular interactions

    Science.gov (United States)

    Berthoz, A.; Pavard, B.; Young, L. R.

    1975-01-01

    The basic characteristics of the sensation of linear horizontal motion have been studied. Objective linear motion was induced by means of a moving cart. Visually induced linear motion perception (linearvection) was obtained by projection of moving images at the periphery of the visual field. Image velocity and luminance thresholds for the appearance of linearvection have been measured and are in the range of those for image motion detection (without sensation of self motion) by the visual system. Latencies of onset are around 1 sec and short term adaptation has been shown. The dynamic range of the visual analyzer as judged by frequency analysis is lower than the vestibular analyzer. Conflicting situations in which visual cues contradict vestibular and other proprioceptive cues show, in the case of linearvection a dominance of vision which supports the idea of an essential although not independent role of vision in self motion perception.

  4. Parallel Architectures and Parallel Algorithms for Integrated Vision Systems. Ph.D. Thesis

    Science.gov (United States)

    Choudhary, Alok Nidhi

    1989-01-01

    Computer vision is regarded as one of the most complex and computationally intensive problems. An integrated vision system (IVS) is a system that uses vision algorithms from all levels of processing to perform for a high level application (e.g., object recognition). An IVS normally involves algorithms from low level, intermediate level, and high level vision. Designing parallel architectures for vision systems is of tremendous interest to researchers. Several issues are addressed in parallel architectures and parallel algorithms for integrated vision systems.

  5. Studies of peripheral sensory nerves in paclitaxel-induced painful peripheral neuropathy: Evidence for mitochondrial dysfunction

    OpenAIRE

    Flatters, Sarah J.L.; Bennett, Gary J.

    2006-01-01

    Paclitaxel chemotherapy frequently induces neuropathic pain during and often persisting after therapy. The mechanisms responsible for this pain are unknown. Using a rat model of paclitaxel-induced painful peripheral neuropathy, we have performed studies to search for peripheral nerve pathology. Paclitaxel-induced mechano-allodynia and mechano-hyperalgesia were evident after a short delay, peaked at day 27 and finally resolved on day 155. Paclitaxel- and vehicle-treated rats were perfused on d...

  6. Peripheral facial nerve dysfunction: CT evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Disbro, M.A.; Harnsberger, H.R.; Osborn, A.G.

    1985-06-01

    Peripheral facial nerve dysfunction may have a clinically apparent or occult cause. The authors reviewed the clinical and radiographic records of 36 patients with peripheral facial nerve dysfunction to obtain information on the location of the suspected lesion and the number, sequence, and type of radiographic evaluations performed. Inadequate clinical evaluations before computed tomography (CT) was done and unnecessary CT examinations were also noted. They have suggested a practical clinical and radiographic scheme to evaluate progressive peripheral facial dysfunction with no apparent cause. If this scheme is applied, unnecessary radiologic tests and delays in diagnosis and treatment may be avoided.

  7. Vision training methods for sports concussion mitigation and management.

    Science.gov (United States)

    Clark, Joseph F; Colosimo, Angelo; Ellis, James K; Mangine, Robert; Bixenmann, Benjamin; Hasselfeld, Kimberly; Graman, Patricia; Elgendy, Hagar; Myer, Gregory; Divine, Jon

    2015-05-05

    There is emerging evidence supporting the use vision training, including light board training tools, as a concussion baseline and neuro-diagnostic tool and potentially as a supportive component to concussion prevention strategies. This paper is focused on providing detailed methods for select vision training tools and reporting normative data for comparison when vision training is a part of a sports management program. The overall program includes standard vision training methods including tachistoscope, Brock's string, and strobe glasses, as well as specialized light board training algorithms. Stereopsis is measured as a means to monitor vision training affects. In addition, quantitative results for vision training methods as well as baseline and post-testing *A and Reaction Test measures with progressive scores are reported. Collegiate athletes consistently improve after six weeks of training in their stereopsis, *A and Reaction Test scores. When vision training is initiated as a team wide exercise, the incidence of concussion decreases in players who participate in training compared to players who do not receive the vision training. Vision training produces functional and performance changes that, when monitored, can be used to assess the success of the vision training and can be initiated as part of a sports medical intervention for concussion prevention.

  8. Near vision spectacle coverage and barriers to near vision ...

    African Journals Online (AJOL)

    easily help to address this visual disability.7 An average cost of near vision spectacle in Ghana is approximately. $ 5.8 Near-vision spectacle could be dispensed as single vision, bifocal or progressive eye glasses to meet near vi- sion needs.2. Recent evidence suggests that the ageing population in. Ghana is increasing ...

  9. AN INVESTIGATION OF VISION PROBLEMS AND THE VISION CARE SYSTEM IN RURAL CHINA.

    Science.gov (United States)

    Bai, Yunli; Yi, Hongmei; Zhang, Linxiu; Shi, Yaojiang; Ma, Xiaochen; Congdon, Nathan; Zhou, Zhongqiang; Boswell, Matthew; Rozelle, Scott

    2014-11-01

    This paper examines the prevalence of vision problems and the accessibility to and quality of vision care in rural China. We obtained data from 4 sources: 1) the National Rural Vision Care Survey; 2) the Private Optometrists Survey; 3) the County Hospital Eye Care Survey; and 4) the Rural School Vision Care Survey. The data from each of the surveys were collected by the authors during 2012. Thirty-three percent of the rural population surveyed self-reported vision problems. Twenty-two percent of subjects surveyed had ever had a vision exam. Among those who self-reported having vision problems, 34% did not wear eyeglasses. Fifty-four percent of those with vision problems who had eyeglasses did not have a vision exam prior to receiving glasses. However, having a vision exam did not always guarantee access to quality vision care. Four channels of vision care service were assessed. The school vision examination program did not increase the usage rate of eyeglasses. Each county-hospital was staffed with three eye-doctors having one year of education beyond high school, serving more than 400,000 residents. Private optometrists often had low levels of education and professional certification. In conclusion, our findings shows that the vision care system in rural China is inadequate and ineffective in meeting the needs of the rural population sampled.

  10. Peripheral retinal nonperfusion associated with chronic myeloid leukemia.

    NARCIS (Netherlands)

    Nobacht, S.; Vandoninck, K.F.; Deutman, A.F.; Klevering, B.J.

    2003-01-01

    PURPOSE: To report a case of peripheral retinal nonperfusion and chronic myeloid leukemia in a 23-year-old woman. DESIGN: Observational case report. METHODS: A complete ophthalmic and systemic evaluation was performed. RESULTS: Ophthalmic examination revealed peripheral retinal nonperfusion with

  11. Clinical Tests of Ultra-Low Vision Used to Evaluate Rudimentary Visual Perceptions Enabled by the BrainPort Vision Device.

    Science.gov (United States)

    Nau, Amy; Bach, Michael; Fisher, Christopher

    2013-01-01

    We evaluated whether existing ultra-low vision tests are suitable for measuring outcomes using sensory substitution. The BrainPort is a vision assist device coupling a live video feed with an electrotactile tongue display, allowing a user to gain information about their surroundings. We enrolled 30 adult subjects (age range 22-74) divided into two groups. Our blind group included 24 subjects ( n = 16 males and n = 8 females, average age 50) with light perception or worse vision. Our control group consisted of six subjects ( n = 3 males, n = 3 females, average age 43) with healthy ocular status. All subjects performed 11 computer-based psychophysical tests from three programs: Basic Assessment of Light Motion, Basic Assessment of Grating Acuity, and the Freiburg Vision Test as well as a modified Tangent Screen. Assessments were performed at baseline and again using the BrainPort after 15 hours of training. Most tests could be used with the BrainPort. Mean success scores increased for all of our tests except contrast sensitivity. Increases were statistically significant for tests of light perception (8.27 ± 3.95 SE), time resolution (61.4% ± 3.14 SE), light localization (44.57% ± 3.58 SE), grating orientation (70.27% ± 4.64 SE), and white Tumbling E on a black background (2.49 logMAR ± 0.39 SE). Motion tests were limited by BrainPort resolution. Tactile-based sensory substitution devices are amenable to psychophysical assessments of vision, even though traditional visual pathways are circumvented. This study is one of many that will need to be undertaken to achieve a common outcomes infrastructure for the field of artificial vision.

  12. Data fusion for a vision-aided radiological detection system: Calibration algorithm performance

    Science.gov (United States)

    Stadnikia, Kelsey; Henderson, Kristofer; Martin, Allan; Riley, Phillip; Koppal, Sanjeev; Enqvist, Andreas

    2018-05-01

    In order to improve the ability to detect, locate, track and identify nuclear/radiological threats, the University of Florida nuclear detection community has teamed up with the 3D vision community to collaborate on a low cost data fusion system. The key is to develop an algorithm to fuse the data from multiple radiological and 3D vision sensors as one system. The system under development at the University of Florida is being assessed with various types of radiological detectors and widely available visual sensors. A series of experiments were devised utilizing two EJ-309 liquid organic scintillation detectors (one primary and one secondary), a Microsoft Kinect for Windows v2 sensor and a Velodyne HDL-32E High Definition LiDAR Sensor which is a highly sensitive vision sensor primarily used to generate data for self-driving cars. Each experiment consisted of 27 static measurements of a source arranged in a cube with three different distances in each dimension. The source used was Cf-252. The calibration algorithm developed is utilized to calibrate the relative 3D-location of the two different types of sensors without need to measure it by hand; thus, preventing operator manipulation and human errors. The algorithm can also account for the facility dependent deviation from ideal data fusion correlation. Use of the vision sensor to determine the location of a sensor would also limit the possible locations and it does not allow for room dependence (facility dependent deviation) to generate a detector pseudo-location to be used for data analysis later. Using manually measured source location data, our algorithm-predicted the offset detector location within an average of 20 cm calibration-difference to its actual location. Calibration-difference is the Euclidean distance from the algorithm predicted detector location to the measured detector location. The Kinect vision sensor data produced an average calibration-difference of 35 cm and the HDL-32E produced an average

  13. Living with vision loss

    Science.gov (United States)

    Diabetes - vision loss; Retinopathy - vision loss; Low vision; Blindness - vision loss ... of visual aids. Some options include: Magnifiers High power reading glasses Devices that make it easier to ...

  14. A child's vision.

    Science.gov (United States)

    Nye, Christina

    2014-06-01

    Implementing standard vision screening techniques in the primary care practice is the most effective means to detect children with potential vision problems at an age when the vision loss may be treatable. A critical period of vision development occurs in the first few weeks of life; thus, it is imperative that serious problems are detected at this time. Although it is not possible to quantitate an infant's vision, evaluating ocular health appropriately can mean the difference between sight and blindness and, in the case of retinoblastoma, life or death. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. MISSION AND VISION, ENVIRONMENTAL SCANNING AND FORMALITY OF STRATEGIC PLANNING AS PREDICTORS OF THE PERFORMANCE OF SMALL AND MEDIUM ENTERPRISES (SMES IN THE GAUTENG PROVINCE OF SOUTH AFRICA

    Directory of Open Access Journals (Sweden)

    Maxwell SANDADA

    2014-07-01

    Full Text Available Faced with volatile business conditions and the hyper competitive market environment, SMEs are continuously focusing on finding ways to improve their performance. This paper attempts to establish the effect of mission and vision, environmental scanning and the formality of the strategic planning process on the performance of SMEs. A quantitative research approach was pursued through a self-administered survey questionnaire. Descriptive statistics, correlation analysis and regression analysis were used to analyse the data. The main findings of the study suggest that, the mission and vision statements, environmental scanning and the formality of strategic planning have a positive effect on the performance of SMEs. The formality of strategic planning emerged as the factor with a stronger impact on SME performance than environmental scanning and mission and vision. The study provides some practical insights for SMEs for improving their performance in line with the identified effect of these three factors. Ultimately, improving their performance along these factors is set to reinforce SME sustainability and which will further stimulate their profitability.

  16. Color vision test

    Science.gov (United States)

    ... present from birth) color vision problems: Achromatopsia -- complete color blindness , seeing only shades of gray Deuteranopia -- difficulty telling ... Vision test - color; Ishihara color vision test Images Color blindness tests References Bowling B. Hereditary fundus dystrophies. In: ...

  17. Impairments to Vision

    Science.gov (United States)

    ... an external Non-Government web site. Impairments to Vision Normal Vision Diabetic Retinopathy Age-related Macular Degeneration In this ... pictures, fixate on the nose to simulate the vision loss. In diabetic retinopathy, the blood vessels in ...

  18. Performance of LED-based fluorescence microscopy to diagnose tuberculosis in a peripheral health centre in Nairobi.

    Directory of Open Access Journals (Sweden)

    Maryline Bonnet

    Full Text Available BACKGROUND: Sputum microscopy is the only tuberculosis (TB diagnostic available at peripheral levels of care in resource limited countries. Its sensitivity is low, particularly in high HIV prevalence settings. Fluorescence microscopy (FM can improve performance of microscopy and with the new light emitting diode (LED technologies could be appropriate for peripheral settings. The study aimed to compare the performance of LED-FM versus Ziehl-Neelsen (ZN microscopy and to assess feasibility of LED-FM at a low level of care in a high HIV prevalence country. METHODS: A prospective study was conducted in an urban health clinic in Nairobi, Kenya. Three sputum specimens were collected over 2 days from suspected TB patients. Each sample was processed with Auramine O and ZN methods and a 4(th specimen was collected for TB culture reference standard. Auramine smears were read using the same microscope, equipped with the FluoLED™ fluorescence illuminator. Inter-reader agreement, reading time and technicians' acceptability assessed feasibility. RESULTS: 497 patients were included and 1394 specimens were collected. The detection yields of LED-FM and ZN microscopy were 20.3% and 20.6% (p = 0.64, respectively. Sensitivity was 73.2% for LED-FM and 72% for ZN microscopy, p = 0.32. It was 96.7% and 95.9% for specificity, p = 0.53. Inter-reader agreement was high (kappa = 0.9. Mean reading time was three times faster than ZN microscopy with very good acceptance by technicians. CONCLUSIONS: Although it did not increase sensitivity, the faster reading time combined with very good acceptance and ease of use supports the introduction of LED-FM at the peripheral laboratory level of high TB and HIV burden countries.

  19. Computer Vision and Image Processing: A Paper Review

    Directory of Open Access Journals (Sweden)

    victor - wiley

    2018-02-01

    Full Text Available Computer vision has been studied from many persective. It expands from raw data recording into techniques and ideas combining digital image processing, pattern recognition, machine learning and computer graphics. The wide usage has attracted many scholars to integrate with many disciplines and fields. This paper provide a survey of the recent technologies and theoretical concept explaining the development of computer vision especially related to image processing using different areas of their field application. Computer vision helps scholars to analyze images and video to obtain necessary information,    understand information on events or descriptions, and scenic pattern. It used method of multi-range application domain with massive data analysis. This paper provides contribution of recent development on reviews related to computer vision, image processing, and their related studies. We categorized the computer vision mainstream into four group e.g., image processing, object recognition, and machine learning. We also provide brief explanation on the up-to-date information about the techniques and their performance.

  20. Robot Vision Library

    Science.gov (United States)

    Howard, Andrew B.; Ansar, Adnan I.; Litwin, Todd E.; Goldberg, Steven B.

    2009-01-01

    The JPL Robot Vision Library (JPLV) provides real-time robot vision algorithms for developers who are not vision specialists. The package includes algorithms for stereo ranging, visual odometry and unsurveyed camera calibration, and has unique support for very wideangle lenses

  1. 77 FR 33017 - Qualification of Drivers; Exemption Applications; Vision

    Science.gov (United States)

    2012-06-04

    .... Molenaar Mr. Molenaar, 59, has complete loss of vision in his right eye since childhood. The best corrected... examination in 2011, his ophthalmologist noted, ``It is my opinion that Gerardus C. Molenaar has sufficient vision to perform driving tasks required to operate a commercial vehicle.'' Mr. Molenaar reported that he...

  2. Gaze-contingent training enhances perceptual skill acquisition.

    Science.gov (United States)

    Ryu, Donghyun; Mann, David L; Abernethy, Bruce; Poolton, Jamie M

    2016-01-01

    The purpose of this study was to determine whether decision-making skill in perceptual-cognitive tasks could be enhanced using a training technique that impaired selective areas of the visual field. Recreational basketball players performed perceptual training over 3 days while viewing with a gaze-contingent manipulation that displayed either (a) a moving window (clear central and blurred peripheral vision), (b) a moving mask (blurred central and clear peripheral vision), or (c) full (unrestricted) vision. During the training, participants watched video clips of basketball play and at the conclusion of each clip made a decision about to which teammate the player in possession of the ball should pass. A further control group watched unrelated videos with full vision. The effects of training were assessed using separate tests of decision-making skill conducted in a pretest, posttest, and 2-week retention test. The accuracy of decision making was greater in the posttest than in the pretest for all three intervention groups when compared with the control group. Remarkably, training with blurred peripheral vision resulted in a further improvement in performance from posttest to retention test that was not apparent for the other groups. The type of training had no measurable impact on the visual search strategies of the participants, and so the training improvements appear to be grounded in changes in information pickup. The findings show that learning with impaired peripheral vision offers a promising form of training to support improvements in perceptual skill.

  3. Central as well as peripheral attentional bottlenecks in dual-task performance activate lateral prefrontal cortices

    Directory of Open Access Journals (Sweden)

    Andre J Szameitat

    2016-03-01

    Full Text Available Human information processing suffers from severe limitations in parallel processing. In particular, when required to respond to two stimuli in rapid succession, processing bottlenecks may appear at central and peripheral stages of task processing. Importantly, it has been suggested that executive functions are needed to resolve the interference arising at such bottlenecks. The aims of the present study were to test whether central attentional limitations (i.e., bottleneck at the decisional response selection stage as well as peripheral limitations (i.e., bottleneck at response initiation both demand executive functions located in the lateral prefrontal cortex. For this, we re-analysed two previous studies, in which a total of 33 participants performed a dual-task according to the paradigm of the psychological refractory period (PRP during fMRI. In one study (N=17, the PRP task consisted of two two-choice response tasks known to suffer from a central bottleneck (CB group. In the other study (N=16, the PRP task consisted of two simple-response tasks known to suffer from a peripheral bottleneck (PB group. Both groups showed considerable dual-task costs in form of slowing of the second response in the dual-task (PRP effect. Imaging results are based on the subtraction of both single-tasks from the dual-task within each group. In the CB group, the bilateral middle frontal gyri and inferior frontal gyri were activated. Higher activation in these areas was associated with lower dual-task costs. In the PB group, the right middle frontal and inferior frontal gyrus were activated. Here, higher activation was associated with higher dual-task costs. In conclusion we suggest that central and peripheral bottlenecks both demand executive functions located in lateral prefrontal cortices. Differences between the CB and PB groups with respect to the exact prefrontal areas activated and the correlational patterns suggest that the executive functions resolving

  4. A roadmap for interpreting the literature on vision and driving.

    Science.gov (United States)

    Owsley, Cynthia; Wood, Joanne M; McGwin, Gerald

    2015-01-01

    Over the past several decades there has been a sharp increase in the number of studies focused on the relationship between vision and driving. The intensified attention to this topic has most likely been stimulated by the lack of an evidence basis for determining vision standards for driving licensure and a poor understanding about how vision impairment impacts driver safety and performance. Clinicians depend on the literature on vision and driving to advise visually impaired patients appropriately about driving fitness. Policy makers also depend on the scientific literature in order to develop guidelines that are evidence-based and are thus fair to persons who are visually impaired. Thus it is important for clinicians and policy makers alike to understand how various study designs and measurement methods should be interpreted so that the conclusions and recommendations they make are not overly broad, too narrowly constrained, or even misguided. We offer a methodological framework to guide interpretations of studies on vision and driving that can also serve as a heuristic for researchers in the area. Here, we discuss research designs and general measurement methods for the study of vision as they relate to driver safety, driver performance, and driver-centered (self-reported) outcomes. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Visions of Vision: An Exploratory Study of the Role College and University Presidents Play in Developing Institutional Vision

    Science.gov (United States)

    McWade, Jessica C.

    2014-01-01

    This qualitative research explores how college and university presidents engage in the process of developing formal institutional vision. The inquiry identifies roles presidents play in vision development, which is often undertaken as part of strategic-planning initiatives. Two constructs of leadership and institutional vision are used to examine…

  6. Peripheral epithelial odontogenic tumor

    International Nuclear Information System (INIS)

    Carzoglio, J.; Tancredi, N.; Capurro, S.; Ravecca, T.; Scarrone, P.

    2006-01-01

    A new case of peripheral epithelial odontogenic tumor (Pindborg tumor) is reported. It is localized in the superior right gingival region, a less frequent site, and has the histopathological features previously reported. Immunochemical studies were performed, revealing a differential positive stain to cytokeratins in tumor cells deeply seated in the tumor mass, probably related to tumoral cell heterogeneity.Interestingly, in this particular case S-100 protein positive reactivity was also detected in arborescent cells intermingled with tumoral cells, resembling Langerhans cells. Even though referred in the literature in central Pindborg tumors, no references were found about their presence in peripheral tumors, like the one that is presented here

  7. Light Vision Color

    Science.gov (United States)

    Valberg, Arne

    2005-04-01

    Light Vision Color takes a well-balanced, interdisciplinary approach to our most important sensory system. The book successfully combines basics in vision sciences with recent developments from different areas such as neuroscience, biophysics, sensory psychology and philosophy. Originally published in 1998 this edition has been extensively revised and updated to include new chapters on clinical problems and eye diseases, low vision rehabilitation and the basic molecular biology and genetics of colour vision. Takes a broad interdisciplinary approach combining basics in vision sciences with the most recent developments in the area Includes an extensive list of technical terms and explanations to encourage student understanding Successfully brings together the most important areas of the subject in to one volume

  8. What Is Low Vision?

    Science.gov (United States)

    ... Your Rights Training Resources Workplace Technology CareerConnect Stories Working as a Senior with Vision Loss For Seniors Age-Related Vision ... Changes Health and Aging Retirement Living Continuing to Work as a Senior with Vision Loss Get Connected About VisionAware Join ...

  9. 77 FR 3552 - Qualification of Drivers; Exemption Applications; Vision

    Science.gov (United States)

    2012-01-24

    ... for moving violations in a CMV. Richard P. Frederiksen Mr. Frederiksen, 29, has had a prosthesis left... ophthalmologist noted, ``I felt his vision was good enough to drive a commercial or personal vehicle. I certify... ophthalmologist noted, ``I feel he has sufficient vision to perform the driving tasks required to operate a...

  10. Static and dynamic postural control in low-vision and normal-vision adults.

    Science.gov (United States)

    Tomomitsu, Mônica S V; Alonso, Angelica Castilho; Morimoto, Eurica; Bobbio, Tatiana G; Greve, Julia M D

    2013-04-01

    This study aimed to evaluate the influence of reduced visual information on postural control by comparing low-vision and normal-vision adults in static and dynamic conditions. Twenty-five low-vision subjects and twenty-five normal sighted adults were evaluated for static and dynamic balance using four protocols: 1) the Modified Clinical Test of Sensory Interaction on Balance on firm and foam surfaces with eyes opened and closed; 2) Unilateral Stance with eyes opened and closed; 3) Tandem Walk; and 4) Step Up/Over. The results showed that the low-vision group presented greater body sway compared with the normal vision during balance on a foam surface (p≤0.001), the Unilateral Stance test for both limbs (p≤0.001), and the Tandem Walk test. The low-vision group showed greater step width (p≤0.001) and slower gait speed (p≤0.004). In the Step Up/Over task, low-vision participants were more cautious in stepping up (right p≤0.005 and left p≤0.009) and in executing the movement (p≤0.001). These findings suggest that visual feedback is crucial for determining balance, especially for dynamic tasks and on foam surfaces. Low-vision individuals had worse postural stability than normal-vision adults in terms of dynamic tests and balance on foam surfaces.

  11. Enhanced Flight Vision Systems and Synthetic Vision Systems for NextGen Approach and Landing Operations

    Science.gov (United States)

    Kramer, Lynda J.; Bailey, Randall E.; Ellis, Kyle K. E.; Williams, Steven P.; Arthur, Jarvis J., III; Prinzel, Lawrence J., III; Shelton, Kevin J.

    2013-01-01

    Synthetic Vision Systems and Enhanced Flight Vision System (SVS/EFVS) technologies have the potential to provide additional margins of safety for aircrew performance and enable operational improvements for low visibility operations in the terminal area environment with equivalent efficiency as visual operations. To meet this potential, research is needed for effective technology development and implementation of regulatory standards and design guidance to support introduction and use of SVS/EFVS advanced cockpit vision technologies in Next Generation Air Transportation System (NextGen) operations. A fixed-base pilot-in-the-loop simulation test was conducted at NASA Langley Research Center that evaluated the use of SVS/EFVS in NextGen low visibility approach and landing operations. Twelve crews flew approach and landing operations in a simulated NextGen Chicago O'Hare environment. Various scenarios tested the potential for using EFVS to conduct approach, landing, and roll-out operations in visibility as low as 1000 feet runway visual range (RVR). Also, SVS was tested to evaluate the potential for lowering decision heights (DH) on certain instrument approach procedures below what can be flown today. Expanding the portion of the visual segment in which EFVS can be used in lieu of natural vision from 100 feet above the touchdown zone elevation to touchdown and rollout in visibilities as low as 1000 feet RVR appears to be viable as touchdown performance was acceptable without any apparent workload penalties. A lower DH of 150 feet and/or possibly reduced visibility minima using SVS appears to be viable when implemented on a Head-Up Display, but the landing data suggests further study for head-down implementations.

  12. VISION development

    International Nuclear Information System (INIS)

    Hernandez, J.E.; Sherwood, R.J.; Whitman, S.R.

    1994-01-01

    VISION is a flexible and extensible object-oriented programming environment for prototyping computer-vision and pattern-recognition algorithms. This year's effort focused on three major areas: documentation, graphics, and support for new applications

  13. Low-level laser therapy improves vision in a patient with retinitis pigmentosa.

    Science.gov (United States)

    Ivandic, Boris T; Ivandic, Tomislav

    2014-03-01

    This case report describes the effects of low-level laser therapy (LLLT) in a single patient with retinitis pigmentosa (RP). RP is a heritable disorder of the retina, which eventually leads to blindness. No therapy is currently available. LLLT was applied using a continuous wave laser diode (780 nm, 10 mW average output at 292 Hz, 50% pulse modulation). The complete retina of eyes was irradiated through the conjunctiva for 40 sec (0.4 J, 0.333 W/cm2) two times per week for 2 weeks (1.6 J). A 55-year-old male patient with advanced RP was treated and followed for 7 years. The patient had complained of nyctalopia and decreasing vision. At first presentation, best visual acuity was 20/50 in each eye. Visual fields were reduced to a central residual of 5 degrees. Tritan-dyschromatopsy was found. Retinal potential was absent in electroretinography. Biomicroscopy showed optic nerve atrophy, and narrow retinal vessels with a typical pattern of retinal pigmentation. After four initial treatments of LLLT, visual acuity increased to 20/20 in each eye. Visual fields normalized except for a mid-peripheral absolute concentric scotoma. Five years after discontinuation of LLLT, a relapse was observed. LLLT was repeated (another four treatments) and restored the initial success. During the next 2 years, 17 additional treatments were performed on an "as needed" basis, to maintain the result. LLLT was shown to improve and maintain vision in a patient with RP, and may thereby have contributed to slowing down blindness.

  14. Transitions between central and peripheral vision create spatial/temporal distortions: a hypothesis concerning the perceived break of the curveball.

    Directory of Open Access Journals (Sweden)

    Arthur Shapiro

    2010-10-01

    Full Text Available The human visual system does not treat all parts of an image equally: the central segments of an image, which fall on the fovea, are processed with a higher resolution than the segments that fall in the visual periphery. Even though the differences between foveal and peripheral resolution are large, these differences do not usually disrupt our perception of seamless visual space. Here we examine a motion stimulus in which the shift from foveal to peripheral viewing creates a dramatic spatial/temporal discontinuity.The stimulus consists of a descending disk (global motion with an internal moving grating (local motion. When observers view the disk centrally, they perceive both global and local motion (i.e., observers see the disk's vertical descent and the internal spinning. When observers view the disk peripherally, the internal portion appears stationary, and the disk appears to descend at an angle. The angle of perceived descent increases as the observer views the stimulus from further in the periphery. We examine the first- and second-order information content in the display with the use of a three-dimensional Fourier analysis and show how our results can be used to describe perceived spatial/temporal discontinuities in real-world situations.The perceived shift of the disk's direction in the periphery is consistent with a model in which foveal processing separates first- and second-order motion information while peripheral processing integrates first- and second-order motion information. We argue that the perceived distortion may influence real-world visual observations. To this end, we present a hypothesis and analysis of the perception of the curveball and rising fastball in the sport of baseball. The curveball is a physically measurable phenomenon: the imbalance of forces created by the ball's spin causes the ball to deviate from a straight line and to follow a smooth parabolic path. However, the curveball is also a perceptual puzzle

  15. Transitions between central and peripheral vision create spatial/temporal distortions: a hypothesis concerning the perceived break of the curveball.

    Science.gov (United States)

    Shapiro, Arthur; Lu, Zhong-Lin; Huang, Chang-Bing; Knight, Emily; Ennis, Robert

    2010-10-13

    The human visual system does not treat all parts of an image equally: the central segments of an image, which fall on the fovea, are processed with a higher resolution than the segments that fall in the visual periphery. Even though the differences between foveal and peripheral resolution are large, these differences do not usually disrupt our perception of seamless visual space. Here we examine a motion stimulus in which the shift from foveal to peripheral viewing creates a dramatic spatial/temporal discontinuity. The stimulus consists of a descending disk (global motion) with an internal moving grating (local motion). When observers view the disk centrally, they perceive both global and local motion (i.e., observers see the disk's vertical descent and the internal spinning). When observers view the disk peripherally, the internal portion appears stationary, and the disk appears to descend at an angle. The angle of perceived descent increases as the observer views the stimulus from further in the periphery. We examine the first- and second-order information content in the display with the use of a three-dimensional Fourier analysis and show how our results can be used to describe perceived spatial/temporal discontinuities in real-world situations. The perceived shift of the disk's direction in the periphery is consistent with a model in which foveal processing separates first- and second-order motion information while peripheral processing integrates first- and second-order motion information. We argue that the perceived distortion may influence real-world visual observations. To this end, we present a hypothesis and analysis of the perception of the curveball and rising fastball in the sport of baseball. The curveball is a physically measurable phenomenon: the imbalance of forces created by the ball's spin causes the ball to deviate from a straight line and to follow a smooth parabolic path. However, the curveball is also a perceptual puzzle because batters often

  16. [Peripheral retinal degenerations--treatment recommendations].

    Science.gov (United States)

    Joussen, A M; Kirchhof, B

    2004-10-01

    This report reviews the clinical appearance of degenerative diseases of the peripheral retina in relationship to the risk of developing a rhegmatogenous retinal detachment. We present recommendations for preventive treatment in eyes at increased risk of developing retinal detachment. Retinal degenerations are common lesions involving the peripheral retina but most of them are clinically insignificant. Lattice degeneration, degenerative retinoschisis, cystic retinal tufts, and very rarely zonular traction tufts can result in rhegmatogenous retinal detachment. Therefore, these lesions have been considered for prophylactic treatment; however, adequate studies have not been performed to date. Most of the peripheral retinal degenerations may not require treatment except in rare, high-risk situations. According to current knowledge there is no higher incidence of secondary pucker or other side effects after laser coagulation. Therefore, generous laser indication is recommended if risk factors apply.

  17. Synthetic vision display evaluation studies

    Science.gov (United States)

    Regal, David M.; Whittington, David H.

    1994-01-01

    The goal of this research was to help us understand the display requirements for a synthetic vision system for the High Speed Civil Transport (HSCT). Four experiments were conducted to examine the effects of different levels of perceptual cue complexity in displays used by pilots in a flare and landing task. Increased levels of texture mapping of terrain and runway produced mixed results, including harder but shorter landings and a lower flare initiation altitude. Under higher workload conditions, increased texture resulted in an improvement in performance. An increase in familiar size cues did not result in improved performance. Only a small difference was found between displays using two patterns of high resolution texture mapping. The effects of increased perceptual cue complexity on performance was not as strong as would be predicted from the pilot's subjective reports or from related literature. A description of the role of a synthetic vision system in the High Speed Civil Transport is provide along with a literature review covering applied research related to perceptual cue usage in aircraft displays.

  18. Multi-Center Evaluation of the Automated Immunohematology Instrument, the ORTHO VISION Analyzer.

    Science.gov (United States)

    Aysola, Agnes; Wheeler, Leslie; Brown, Richard; Denham, Rebecca; Colavecchia, Connie; Pavenski, Katerina; Krok, Elizabeth; Hayes, Chelsea; Klapper, Ellen

    2017-02-01

    ORTHO VISION Analyzer (Vision), is an immunohematology instrument using ID-MT gel card technology with digital image processing. It has a continuous, random sample access with STAT priority processing. The efficiency and ease of operation of Vision was evaluated at 5 medical centers. De-identified patient samples were tested on the ORTHO ProVue Analyzer (ProVue) and repeated on the Vision mimicking the daily workload pattern. Turnaround times (TAT) were collected and compared. Operators rated key features of the analyzer on a scale of 1 to 5. A total of 507 samples were tested on both instruments at the 5 trial sites. The mean TAT (SD) were 31.6 minutes (5.5) with Vision and 35.7 minutes (8.4) with ProVue, which renders a 12% reduction. Type and screens were performed on 381 samples; the mean TAT (SD) was 32.2 minutes (4.5) with Vision and 37.0 minutes (7.4) with ProVue. Antibody identification with eleven panel cells was performed on 134 samples on Vision; TAT (SD) was 43.2 minutes (8.3). The installation, training, configuration, maintenance and validation processes are all streamlined to provide a short implementation time. The average rating of main functions by the operators was 4.1 to 4.8. Opportunities for improvement, such as flexibility with editing QC results, maintenance schedule, and printing options were identified. The capabilities to perform serial dilutions, to accept pediatric tubes, and review results by e-Connectivity are enhancements over the ProVue. Vision provides shorter TAT compared to ProVue. Every site described a positive experience using Vision. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  19. Vision-based interaction

    CERN Document Server

    Turk, Matthew

    2013-01-01

    In its early years, the field of computer vision was largely motivated by researchers seeking computational models of biological vision and solutions to practical problems in manufacturing, defense, and medicine. For the past two decades or so, there has been an increasing interest in computer vision as an input modality in the context of human-computer interaction. Such vision-based interaction can endow interactive systems with visual capabilities similar to those important to human-human interaction, in order to perceive non-verbal cues and incorporate this information in applications such

  20. A digital retina-like low-level vision processor.

    Science.gov (United States)

    Mertoguno, S; Bourbakis, N G

    2003-01-01

    This correspondence presents the basic design and the simulation of a low level multilayer vision processor that emulates to some degree the functional behavior of a human retina. This retina-like multilayer processor is the lower part of an autonomous self-organized vision system, called Kydon, that could be used on visually impaired people with a damaged visual cerebral cortex. The Kydon vision system, however, is not presented in this paper. The retina-like processor consists of four major layers, where each of them is an array processor based on hexagonal, autonomous processing elements that perform a certain set of low level vision tasks, such as smoothing and light adaptation, edge detection, segmentation, line recognition and region-graph generation. At each layer, the array processor is a 2D array of k/spl times/m hexagonal identical autonomous cells that simultaneously execute certain low level vision tasks. Thus, the hardware design and the simulation at the transistor level of the processing elements (PEs) of the retina-like processor and its simulated functionality with illustrative examples are provided in this paper.

  1. Clinical impact of exercise in patients with peripheral arterial disease.

    Science.gov (United States)

    Novakovic, Marko; Jug, Borut; Lenasi, Helena

    2017-08-01

    Increasing prevalence, high morbidity and mortality, and decreased health-related quality of life are hallmarks of peripheral arterial disease. About one-third of peripheral arterial disease patients have intermittent claudication with deleterious effects on everyday activities, such as walking. Exercise training improves peripheral arterial disease symptoms and is recommended as first line therapy for peripheral arterial disease. This review examines the effects of exercise training beyond improvements in walking distance, namely on vascular function, parameters of inflammation, activated hemostasis and oxidative stress, and quality of life. Exercise training not only increases walking distance and physiologic parameters in patients with peripheral arterial disease, but also improves the cardiovascular risk profile by helping patients achieve better control of hypertension, hyperglycemia, obesity and dyslipidemia, thus further reducing cardiovascular risk and the prevalence of coexistent atherosclerotic diseases. American guidelines suggest supervised exercise training, performed for a minimum of 30-45 min, at least three times per week, for at least 12 weeks. Walking is the most studied exercise modality and its efficacy in improving cardiovascular parameters in patients with peripheral arterial disease has been extensively proven. As studies have shown that supervised exercise training improves walking performance, cardiovascular parameters and quality of life in patients with peripheral arterial disease, it should be encouraged and more often prescribed.

  2. Vision Based Tracker for Dart-Catching Robot

    OpenAIRE

    Linderoth, Magnus; Robertsson, Anders; Åström, Karl; Johansson, Rolf

    2009-01-01

    This paper describes how high-speed computer vision can be used in a motion control application. The specific application investigated is a dart catching robot. Computer vision is used to detect a flying dart and a filtering algorithm predicts its future trajectory. This will give data to a robot controller allowing it to catch the dart. The performance of the implemented components indicates that the dart catching application can be made to work well. Conclusions are also made about what fea...

  3. Effects of thai foot massage on balance performance in diabetic patients with peripheral neuropathy: a randomized parallel-controlled trial.

    Science.gov (United States)

    Chatchawan, Uraiwan; Eungpinichpong, Wichai; Plandee, Piyawan; Yamauchi, Junichiro

    2015-04-20

    BACKGROUND Peripheral neuropathy is the most common complications of diabetic patients and leads to loss of plantar cutaneous sensation, movement perception, and body balance. Thai foot massage is an alternative therapy to improve balance. Therefore, the purpose of this study was to investigate the effects of Thai foot massage on balance performance in diabetic patients with peripheral neuropathy. MATERIAL AND METHODS Sixty patients with type-2 diabetes were recruited and randomly assigned into either the Thai foot massage or control groups. The Thai foot massage group received a modified Thai traditional foot massage for 30 min, 3 days per week for 2 weeks. We measured timed up and go (TUG), one leg stance: OLS), the range of motion (ROM) of the foot, and foot sensation (SWMT) before treatment, after the first single session, and after the 2-week treatment. RESULTS After the single treatment session, only the Thai foot massage group showed a significant improvement in TUG. After the 2-week treatment, both Thai foot massage and control groups showed a significant improvement of TUG and OLS (Pfoot massage group showed better improvement in TUG than the control group (pfoot massage group also showed significant improvements in ROM and SWMT after the 2-week treatment. CONCLUSIONS The results of this study suggest that Thai foot massage is a viable alternative treatment for balance performance, ROM of the foot, and the foot sensation in diabetic patients with peripheral neuropathy.

  4. Water soluble peripheral and non-peripheral tetrasubstituted zinc phthalocyanines: Synthesis, photochemistry and bovine serum albumin binding behavior

    Energy Technology Data Exchange (ETDEWEB)

    Çakır, Volkan; Çakır, Dilek [Department of Chemistry, Faculty of Sciences, Karadeniz Technical University, 61080 Trabzon (Turkey); Pişkin, Mehmet [Department of Food Technology, Çanakkale Vocational School of Technical Sciences, Çanakkale Onsekiz Mart University, 17100 Çanakkale (Turkey); Durmuş, Mahmut [Gebze Institute of Technology, Department of Chemistry, PO Box 141, Gebze 41400, Kocaeli (Turkey); Bıyıklıoğlu, Zekeriya, E-mail: zekeriya_61@yahoo.com [Department of Chemistry, Faculty of Sciences, Karadeniz Technical University, 61080 Trabzon (Turkey)

    2014-10-15

    The new peripherally and non-peripherally tetra-1,3-bis[3-(diethylamino)phenoxy]propan-2-ol substituted zinc(II) phthalocyanine complexes (2a and 3a) and their quaternized amphiphilic derivatives (2b and 3b) have been synthesized and characterized using UV–vis, FT-IR, {sup 1}H-NMR, {sup 13}C-NMR, MS spectroscopic data and elemental analysis for the first time. The quaternized complexes (2b and 3b) show excellent solubility in water and DMSO which makes them potential photosensitizers for use in photodynamic therapy (PDT) of cancer. The photochemical (singlet oxygen generation and photodegradation under light irradiation) properties of these novel phthalocyanines are investigated in dimethylsulfoxide (DMSO) for non-quaternized complexes and in DMSO, phosphate buffered solution (PBS) or PBS+triton X-100 (TX) solution for quaternized complexes. In this study, the effects of the aggregation of the molecules, quaternization, position of the substituents (peripherally or non-peripherally) and nature of the solvents (DMSO, PBS or PBS+triton X-100) on the photochemical parameters of the zinc (II) phthalocyanines are also reported. In addition, a spectroscopic investigation of the binding behavior of the quaternized zinc(II) phthalocyanine complexes to bovine serum albumin (BSA) is also presented in this work. - Highlights: • Synthesis of zinc phthalocyanines is performed. • Photophysical and photochemical properties of phthalocyanines are studied. • Photodynamic therapy studies are performed.

  5. Water soluble peripheral and non-peripheral tetrasubstituted zinc phthalocyanines: Synthesis, photochemistry and bovine serum albumin binding behavior

    International Nuclear Information System (INIS)

    Çakır, Volkan; Çakır, Dilek; Pişkin, Mehmet; Durmuş, Mahmut; Bıyıklıoğlu, Zekeriya

    2014-01-01

    The new peripherally and non-peripherally tetra-1,3-bis[3-(diethylamino)phenoxy]propan-2-ol substituted zinc(II) phthalocyanine complexes (2a and 3a) and their quaternized amphiphilic derivatives (2b and 3b) have been synthesized and characterized using UV–vis, FT-IR, 1 H-NMR, 13 C-NMR, MS spectroscopic data and elemental analysis for the first time. The quaternized complexes (2b and 3b) show excellent solubility in water and DMSO which makes them potential photosensitizers for use in photodynamic therapy (PDT) of cancer. The photochemical (singlet oxygen generation and photodegradation under light irradiation) properties of these novel phthalocyanines are investigated in dimethylsulfoxide (DMSO) for non-quaternized complexes and in DMSO, phosphate buffered solution (PBS) or PBS+triton X-100 (TX) solution for quaternized complexes. In this study, the effects of the aggregation of the molecules, quaternization, position of the substituents (peripherally or non-peripherally) and nature of the solvents (DMSO, PBS or PBS+triton X-100) on the photochemical parameters of the zinc (II) phthalocyanines are also reported. In addition, a spectroscopic investigation of the binding behavior of the quaternized zinc(II) phthalocyanine complexes to bovine serum albumin (BSA) is also presented in this work. - Highlights: • Synthesis of zinc phthalocyanines is performed. • Photophysical and photochemical properties of phthalocyanines are studied. • Photodynamic therapy studies are performed

  6. Eye movements of patients with tunnel vision while walking.

    Science.gov (United States)

    Vargas-Martín, Fernando; Peli, Eli

    2006-12-01

    To determine how severe peripheral field loss (PFL) affects the dispersion of eye movements relative to the head in patients walking in real environments. This information should help to define the visual field and clearance requirements for head-mounted mobility visual aids. Eye positions relative to the head were recorded in five patients with retinitis pigmentosa who had less than 15 degrees of visual field and in three normally sighted people, each walking in varied environments for more than 30 minutes. The eye-position recorder was made portable by modifying a head-mounted system (ISCAN, Burlington, MA). Custom data processing was implemented, to reject unreliable data. Sample standard deviations of eye position (dispersion) were compared across subject groups and environments. The patients with PFL exhibited narrower horizontal eye-position dispersions than did the normally sighted subjects (9.4 degrees vs. 14.2 degrees , P vision information. Their horizontal scanning was actually reduced, possibly because of lack of peripheral stimulation. The results suggest that a field of view as wide as 40 degrees may be needed for closed (immersive) head-mounted mobility aids, whereas a much narrower display, perhaps as narrow as 20 degrees , may be sufficient with an open design.

  7. Barriers to accessing low vision services.

    Science.gov (United States)

    Pollard, Tamara L; Simpson, John A; Lamoureux, Ecosse L; Keeffe, Jill E

    2003-07-01

    To investigate barriers to accessing low vision services in Australia. Adults with a vision impairment (vision difficulties, duration of vision loss and satisfaction with vision and also examined issues of awareness of low vision services and referral to services. Focus groups were also conducted with vision impaired (Vision Australia Foundation. The discussions were recorded and transcribed. The questionnaire revealed that referral to low vision services was associated with a greater degree of vision loss (p = 0.002) and a greater self-perception of low vision (p = 0.005) but that referral was not associated with satisfaction (p = 0.144) or difficulties related to vision (p = 0.169). Participants with mild and moderate vision impairment each reported similar levels of difficulties with daily activities and satisfaction with their vision (p > 0.05). However, there was a significant difference in the level of difficulties experienced with daily activities between those with mild-moderate and severe vision impairment (p low vision services related to awareness of services among the general public and eye care professionals, understanding of low vision and the services available, acceptance of low vision, the referral process, and transport. In addition to the expected difficulties with lack of awareness of services by people with low vision, many people do not understand what the services provide and do not identify themselves as having low vision. Knowledge of these barriers, from the perspective of people with low vision, can now be used to guide the development and content of future health-promotion campaigns.

  8. The absolute threshold of colour vision in the horse.

    Directory of Open Access Journals (Sweden)

    Lina S V Roth

    Full Text Available Arrhythmic mammals are active both during day and night if they are allowed. The arrhythmic horses are in possession of one of the largest terrestrial animal eyes and the purpose of this study is to reveal whether their eye is sensitive enough to see colours at night. During the day horses are known to have dichromatic colour vision. To disclose whether they can discriminate colours in dim light a behavioural dual choice experiment was performed. We started the training and testing at daylight intensities and the horses continued to choose correctly at a high frequency down to light intensities corresponding to moonlight. One Shetland pony mare, was able to discriminate colours at 0.08 cd/m(2, while a half blood gelding, still discriminated colours at 0.02 cd/m(2. For comparison, the colour vision limit for several human subjects tested in the very same experiment was also 0.02 cd/m(2. Hence, the threshold of colour vision for the horse that performed best was similar to that of the humans. The behavioural results are in line with calculations of the sensitivity of cone vision where the horse eye and human eye again are similar. The advantage of the large eye of the horse lies not in colour vision at night, but probably instead in achromatic tasks where presumably signal summation enhances sensitivity.

  9. Correction for near vision in pseudophakic patients

    Directory of Open Access Journals (Sweden)

    Dujić Mirjana

    2004-01-01

    Full Text Available Objective of the study was to show the mean values of correction for near vision and to discuss the presbyopic correction in pseudophakic patients. Setting was the Eye department where authors work. Inclusion criteria for 55 patients were native or corrected distant vision of 0.8-1.0 on Snellen's chart; 0,6 on Jagger's chart for near vision; round pupil and good position of the implant. Biometry of the anterior chamber depth with Alcon biophysics during distant and near vision was performed in our study. „Hi square" test was carried out and it was concluded that patients younger than 59 years (41 eyes had median correction of +2.0 dsph, while patients older than 60 years (36 eyes had correction of+3.0 dsph, but it was not statistically significant. There was no statistically significant difference of the correction between pseudophakic (41 and phakic (19 eyes in patients younger than 59 years. The anterior movement of the IOL was 0.18 mm in the younger group and 0.15 mm in the older group. With good IOL movement and new materials which could have changeable refractive power, the problem of pseudophakic correction for near vision might be solved.

  10. Deep learning: Using machine learning to study biological vision

    OpenAIRE

    Majaj, Najib; Pelli, Denis

    2017-01-01

    Today most vision-science presentations mention machine learning. Many neuroscientists use machine learning to decode neural responses. Many perception scientists try to understand recognition by living organisms. To them, machine learning offers a reference of attainable performance based on learned stimuli. This brief overview of the use of machine learning in biological vision touches on its strengths, weaknesses, milestones, controversies, and current directions.

  11. Some examples of image warping for low vision prosthesis

    Science.gov (United States)

    Juday, Richard D.; Loshin, David S.

    1988-01-01

    NASA has developed an image processor, the Programmable Remapper, for certain functions in machine vision. The Remapper performs a highly arbitrary geometric warping of an image at video rate. It might ultimately be shrunk to a size and cost that could allow its use in a low-vision prosthesis. Coordinate warpings have been developed for retinitis pigmentosa (tunnel vision) and for maculapathy (loss of central field) that are intended to make best use of the patient's remaining viable retina. The rationales and mathematics are presented for some warpings that we will try in clinical studies using the Remapper's prototype.

  12. Computation and parallel implementation for early vision

    Science.gov (United States)

    Gualtieri, J. Anthony

    1990-01-01

    The problem of early vision is to transform one or more retinal illuminance images-pixel arrays-to image representations built out of such primitive visual features such as edges, regions, disparities, and clusters. These transformed representations form the input to later vision stages that perform higher level vision tasks including matching and recognition. Researchers developed algorithms for: (1) edge finding in the scale space formulation; (2) correlation methods for computing matches between pairs of images; and (3) clustering of data by neural networks. These algorithms are formulated for parallel implementation of SIMD machines, such as the Massively Parallel Processor, a 128 x 128 array processor with 1024 bits of local memory per processor. For some cases, researchers can show speedups of three orders of magnitude over serial implementations.

  13. The Effects of Various Mounting Systems of near Magnification on Reading Performance and Preference in School-Age Students with Low Vision

    Science.gov (United States)

    Lusk, Kelly E.

    2012-01-01

    This single-subject study explored the effects of different mounting systems of prescribed near magnification (handheld, stand-mounted, spectacle-mounted, and electronic) on reading performance and preference in students with low vision. Participants included five students ranging from 3rd to 11th grade, and with various etiologies. Reading…

  14. Blue-yellow colour vision impairment and cognitive deficits in occasional and dependent stimulant users.

    Science.gov (United States)

    Hulka, Lea M; Wagner, Michael; Preller, Katrin H; Jenni, Daniela; Quednow, Boris B

    2013-04-01

    Specific blue-yellow colour vision impairment has been reported in dependent cocaine users and it was postulated that drug-induced changes in retinal dopamine neurotransmission are responsible. However, it is unclear whether these changes are confined to chronic cocaine users, whether they are specific for dopaminergic stimulants such as cocaine and amphetamine and whether they are related to cognitive functions such as working memory, encoding and consolidation. In 47 occasional and 29 dependent cocaine users, 23 MDMA (commonly known as 'ecstasy') users and 47 stimulant-naive controls, colour vision discrimination was measured with the Lanthony Desaturated Panel D-15 Test and memory performance with the Auditory Verbal Learning Test. Both occasional and dependent cocaine users showed higher colour confusion indices than controls. Users of the serotonergic stimulant MDMA (26%), occasional (30%) and dependent cocaine users (34%) exhibited more frequent blue-yellow colour vision disorders compared to controls (9%). Inferior performance of MDMA users was caused by a subgroup with high amphetamine co-use (55%), while MDMA use alone was not associated with decreased blue-yellow discrimination (0%). Cognitive performance was worse in cocaine users with colour vision disorder compared to users and controls with intact colour vision and both colour vision impairment and cognitive deficits were related to cocaine use. Occasional cocaine and amphetamine use might induce blue-yellow colour vision impairment, whereas the serotonergic stimulant MDMA does not impair colour vision. The association between colour vision impairment and cognitive deficits in cocaine users may reflect that retinal and cerebral dopamine alterations are linked to a certain degree.

  15. The Need for a Uniform Method of Recording and Reporting Functional Vision Assessments

    Science.gov (United States)

    Shaw, Rona; Russotti, Joanne; Strauss-Schwartz, Judy; Vail, Helen; Kahn, Ronda

    2009-01-01

    The use of functional vision by school-age students who have visual impairments, including those with additional disabilities, is typically reported by teachers of students with visual impairments. Functional vision assessments determine how well a student uses his or her vision to perform tasks throughout the school day. The information that is…

  16. Trifocal intraocular lenses: a comparison of the visual performance and quality of vision provided by two different lens designs

    Directory of Open Access Journals (Sweden)

    Gundersen KG

    2017-06-01

    Full Text Available Kjell G Gundersen,1 Rick Potvin2 1IFocus Øyeklinikk AS, Haugesund, Norway; 2Science in Vision, Akron, NY, USA Purpose: To compare two different diffractive trifocal intraocular lens (IOL designs, evaluating longer-term refractive outcomes, visual acuity (VA at various distances, low contrast VA and quality of vision.Patients and methods: Patients with binocularly implanted trifocal IOLs of two different designs (FineVision [FV] and Panoptix [PX] were evaluated 6 months to 2 years after surgery. Best distance-corrected and uncorrected VA were tested at distance (4 m, intermediate (80 and 60 cm and near (40 cm. A binocular defocus curve was collected with the subject’s best distance correction in place. The preferred reading distance was determined along with the VA at that distance. Low contrast VA at distance was also measured. Quality of vision was measured with the National Eye Institute Visual Function Questionnaire near subset and the Quality of Vision questionnaire.Results: Thirty subjects in each group were successfully recruited. The binocular defocus curves differed only at vergences of −1.0 D (FV better, P=0.02, −1.5 and −2.00 D (PX better, P<0.01 for both. Best distance-corrected and uncorrected binocular vision were significantly better for the PX lens at 60 cm (P<0.01 with no significant differences at other distances. The preferred reading distance was between 42 and 43 cm for both lenses, with the VA at the preferred reading distance slightly better with the PX lens (P=0.04. There were no statistically significant differences by lens for low contrast VA (P=0.1 or for quality of vision measures (P>0.3.Conclusion: Both trifocal lenses provided excellent distance, intermediate and near vision, but several measures indicated that the PX lens provided better intermediate vision at 60 cm. This may be important to users of tablets and other handheld devices. Quality of vision appeared similar between the two lens designs

  17. Predicting Visual Disability in Glaucoma With Combinations of Vision Measures.

    Science.gov (United States)

    Lin, Stephanie; Mihailovic, Aleksandra; West, Sheila K; Johnson, Chris A; Friedman, David S; Kong, Xiangrong; Ramulu, Pradeep Y

    2018-04-01

    We characterized vision in glaucoma using seven visual measures, with the goals of determining the dimensionality of vision, and how many and which visual measures best model activity limitation. We analyzed cross-sectional data from 150 older adults with glaucoma, collecting seven visual measures: integrated visual field (VF) sensitivity, visual acuity, contrast sensitivity (CS), area under the log CS function, color vision, stereoacuity, and visual acuity with noise. Principal component analysis was used to examine the dimensionality of vision. Multivariable regression models using one, two, or three vision tests (and nonvisual predictors) were compared to determine which was best associated with Rasch-analyzed Glaucoma Quality of Life-15 (GQL-15) person measure scores. The participants had a mean age of 70.2 and IVF sensitivity of 26.6 dB, suggesting mild-to-moderate glaucoma. All seven vision measures loaded similarly onto the first principal component (eigenvectors, 0.220-0.442), which explained 56.9% of the variance in vision scores. In models for GQL scores, the maximum adjusted- R 2 values obtained were 0.263, 0.296, and 0.301 when using one, two, and three vision tests in the models, respectively, though several models in each category had similar adjusted- R 2 values. All three of the best-performing models contained CS. Vision in glaucoma is a multidimensional construct that can be described by several variably-correlated vision measures. Measuring more than two vision tests does not substantially improve models for activity limitation. A sufficient description of disability in glaucoma can be obtained using one to two vision tests, especially VF and CS.

  18. The CCH Vision Stimulation Program for Infants with Low Vision: Preliminary Results.

    Science.gov (United States)

    Leguire, L. E.; And Others

    1992-01-01

    This study evaluated the Columbus (Ohio) Children's Hospital vision stimulation program, involving in-home intervention with 15 visually impaired infants. Comparison with controls indicated benefits of appropriate vision stimulation in increasing the neural foundation for vision and visual-motor function in visually impaired infants. (Author/DB)

  19. The ontology of vision. The invisible, consciousness of Living matter.

    Directory of Open Access Journals (Sweden)

    Giorgia eFiorio

    2016-02-01

    Full Text Available If I close my eyes, the absence of light activates the peripheral cells devoted to the perception of darkness. The awareness of ‘seeing oneself seeing’ is in its essence a thought, one that is internal to the vision and previous to any object of sight. To this amphibious faculty, the diaphanous color of darkness, Aristotle assigns the principle of knowledge. Vision is a whole perceptual system, not a channel of sense. Functions of vision are interweaved to the texture of human interaction within a terrestrial environment that is in turn contained into the cosmic order. Within the internal resonance of a double reflection, the living being is the transitive host between two orders of scale, both bigger and smaller than the individual and unity. In the perceptual integrative system of human vision, the convergence-divergence of the corporeal presence and the diffraction of its own appearance is the margin. The sensation of being no longer coincides with the breath of life, it does not seems ‘real’ without the trace of some visible evidence and its simultaneous ‘sharing.’ Without a shadow, without an imprint, and destined for multiple invisible witnesses, the numeric copia of the physical presence inhabits the transient memory of our electronic prostheses. A rudimentary ‘visuality’ replaces tangible experience dissipating its meaning and the awareness of being alive. Transversal to the civilizations of the ancient world, through different orders of function and status, the anthropomorphic figuration of archaic sculpture questions the idea of Being. Ancient statues do not appear in order to be visible as artworks, but rather to exist. The awareness of human finiteness seals the compulsion to ‘give body’ to an invisible apparition that shapes the figuration of Being as the corporeal expression of an ontogenetic waking of human consciousness.Subject and object, the term humanum fathoms the relationship between matter and its living

  20. A smart sensor-based vision system: implementation and evaluation

    International Nuclear Information System (INIS)

    Elouardi, A; Bouaziz, S; Dupret, A; Lacassagne, L; Klein, J O; Reynaud, R

    2006-01-01

    One of the methods of solving the computational complexity of image-processing is to perform some low-level computations on the sensor focal plane. This paper presents a vision system based on a smart sensor. PARIS1 (Programmable Analog Retina-like Image Sensor1) is the first prototype used to evaluate the architecture of an on-chip vision system based on such a sensor coupled with a microcontroller. The smart sensor integrates a set of analog and digital computing units. This architecture paves the way for a more compact vision system and increases the performances reducing the data flow exchanges with a microprocessor in control. A system has been implemented as a proof-of-concept and has enabled us to evaluate the performance requirements for a possible integration of a microcontroller on the same chip. The used approach is compared with two architectures implementing CMOS active pixel sensors (APS) and interfaced to the same microcontroller. The comparison is related to image processing computation time, processing reliability, programmability, precision, bandwidth and subsequent stages of computations

  1. A smart sensor-based vision system: implementation and evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Elouardi, A; Bouaziz, S; Dupret, A; Lacassagne, L; Klein, J O; Reynaud, R [Institute of Fundamental Electronics, Bat. 220, Paris XI University, 91405 Orsay (France)

    2006-04-21

    One of the methods of solving the computational complexity of image-processing is to perform some low-level computations on the sensor focal plane. This paper presents a vision system based on a smart sensor. PARIS1 (Programmable Analog Retina-like Image Sensor1) is the first prototype used to evaluate the architecture of an on-chip vision system based on such a sensor coupled with a microcontroller. The smart sensor integrates a set of analog and digital computing units. This architecture paves the way for a more compact vision system and increases the performances reducing the data flow exchanges with a microprocessor in control. A system has been implemented as a proof-of-concept and has enabled us to evaluate the performance requirements for a possible integration of a microcontroller on the same chip. The used approach is compared with two architectures implementing CMOS active pixel sensors (APS) and interfaced to the same microcontroller. The comparison is related to image processing computation time, processing reliability, programmability, precision, bandwidth and subsequent stages of computations.

  2. Machine Vision Handbook

    CERN Document Server

    2012-01-01

    The automation of visual inspection is becoming more and more important in modern industry as a consistent, reliable means of judging the quality of raw materials and manufactured goods . The Machine Vision Handbook  equips the reader with the practical details required to engineer integrated mechanical-optical-electronic-software systems. Machine vision is first set in the context of basic information on light, natural vision, colour sensing and optics. The physical apparatus required for mechanized image capture – lenses, cameras, scanners and light sources – are discussed followed by detailed treatment of various image-processing methods including an introduction to the QT image processing system. QT is unique to this book, and provides an example of a practical machine vision system along with extensive libraries of useful commands, functions and images which can be implemented by the reader. The main text of the book is completed by studies of a wide variety of applications of machine vision in insp...

  3. Diabetes and obesity are the main metabolic drivers of peripheral neuropathy.

    Science.gov (United States)

    Callaghan, Brian C; Gao, LeiLi; Li, Yufeng; Zhou, Xianghai; Reynolds, Evan; Banerjee, Mousumi; Pop-Busui, Rodica; Feldman, Eva L; Ji, Linong

    2018-04-01

    To determine the associations between individual metabolic syndrome (MetS) components and peripheral neuropathy in a large population-based cohort from Pinggu, China. A cross-sectional, randomly selected, population-based survey of participants from Pinggu, China was performed. Metabolic phenotyping and neuropathy outcomes were performed by trained personnel. Glycemic status was defined according to the American Diabetes Association criteria, and the MetS using modified consensus criteria (body mass index instead of waist circumference). The primary peripheral neuropathy outcome was the Michigan Neuropathy Screening Instrument (MNSI) examination. Secondary outcomes were the MNSI questionnaire and monofilament testing. Multivariable models were used to assess for associations between individual MetS components and peripheral neuropathy. Tree-based methods were used to construct a classifier for peripheral neuropathy using demographics and MetS components. The mean (SD) age of the 4002 participants was 51.6 (11.8) and 51.0% were male; 37.2% of the population had normoglycemia, 44.0% prediabetes, and 18.9% diabetes. The prevalence of peripheral neuropathy increased with worsening glycemic status (3.25% in normoglycemia, 6.29% in prediabetes, and 15.12% in diabetes, P peripheral neuropathy. Age, diabetes, and weight were the primary splitters in the classification tree for peripheral neuropathy. Similar to previous studies, diabetes and obesity are the main metabolic drivers of peripheral neuropathy. The consistency of these results reinforces the urgent need for effective interventions that target these metabolic factors to prevent and/or treat peripheral neuropathy.

  4. Augmented models for improving vision control of a mobile robot

    DEFF Research Database (Denmark)

    Andersen, Gert Lysgaard; Christensen, Anders C.; Ravn, Ole

    1994-01-01

    obtain good performance even when using standard low cost equipment and a comparatively low sampling rate. The plant model is a compound of kinematic, dynamic and sensor submodels, all integrated into a discrete state space representation. An intelligent strategy is applied for the vision sensor......This paper describes the modelling phases for the design of a path tracking vision controller for a three wheeled mobile robot. It is shown that, by including the dynamic characteristics of vision and encoder sensors and implementing the total system in one multivariable control loop, one can...

  5. Vision restoration after brain and retina damage: the "residual vision activation theory".

    Science.gov (United States)

    Sabel, Bernhard A; Henrich-Noack, Petra; Fedorov, Anton; Gall, Carolin

    2011-01-01

    Vision loss after retinal or cerebral visual injury (CVI) was long considered to be irreversible. However, there is considerable potential for vision restoration and recovery even in adulthood. Here, we propose the "residual vision activation theory" of how visual functions can be reactivated and restored. CVI is usually not complete, but some structures are typically spared by the damage. They include (i) areas of partial damage at the visual field border, (ii) "islands" of surviving tissue inside the blind field, (iii) extrastriate pathways unaffected by the damage, and (iv) downstream, higher-level neuronal networks. However, residual structures have a triple handicap to be fully functional: (i) fewer neurons, (ii) lack of sufficient attentional resources because of the dominant intact hemisphere caused by excitation/inhibition dysbalance, and (iii) disturbance in their temporal processing. Because of this resulting activation loss, residual structures are unable to contribute much to everyday vision, and their "non-use" further impairs synaptic strength. However, residual structures can be reactivated by engaging them in repetitive stimulation by different means: (i) visual experience, (ii) visual training, or (iii) noninvasive electrical brain current stimulation. These methods lead to strengthening of synaptic transmission and synchronization of partially damaged structures (within-systems plasticity) and downstream neuronal networks (network plasticity). Just as in normal perceptual learning, synaptic plasticity can improve vision and lead to vision restoration. This can be induced at any time after the lesion, at all ages and in all types of visual field impairments after retinal or brain damage (stroke, neurotrauma, glaucoma, amblyopia, age-related macular degeneration). If and to what extent vision restoration can be achieved is a function of the amount of residual tissue and its activation state. However, sustained improvements require repetitive

  6. Filtering and polychromatic vision in mantis shrimps: themes in visible and ultraviolet vision.

    Science.gov (United States)

    Cronin, Thomas W; Bok, Michael J; Marshall, N Justin; Caldwell, Roy L

    2014-01-01

    Stomatopod crustaceans have the most complex and diverse assortment of retinal photoreceptors of any animals, with 16 functional classes. The receptor classes are subdivided into sets responsible for ultraviolet vision, spatial vision, colour vision and polarization vision. Many of these receptor classes are spectrally tuned by filtering pigments located in photoreceptors or overlying optical elements. At visible wavelengths, carotenoproteins or similar substances are packed into vesicles used either as serial, intrarhabdomal filters or lateral filters. A single retina may contain a diversity of these filtering pigments paired with specific photoreceptors, and the pigments used vary between and within species both taxonomically and ecologically. Ultraviolet-filtering pigments in the crystalline cones serve to tune ultraviolet vision in these animals as well, and some ultraviolet receptors themselves act as birefringent filters to enable circular polarization vision. Stomatopods have reached an evolutionary extreme in their use of filter mechanisms to tune photoreception to habitat and behaviour, allowing them to extend the spectral range of their vision both deeper into the ultraviolet and further into the red.

  7. Micro Vision

    OpenAIRE

    Ohba, Kohtaro; Ohara, Kenichi

    2007-01-01

    In the field of the micro vision, there are few researches compared with macro environment. However, applying to the study result for macro computer vision technique, you can measure and observe the micro environment. Moreover, based on the effects of micro environment, it is possible to discovery the new theories and new techniques.

  8. Colour Vision Impairment in Young Alcohol Consumers.

    Directory of Open Access Journals (Sweden)

    Alódia Brasil

    Full Text Available Alcohol consumption among young adults is widely accepted in modern society and may be the starting point for abusive use of alcohol at later stages of life. Chronic alcohol exposure can lead to visual function impairment. In the present study, we investigated the spatial luminance contrast sensitivity, colour arrangement ability, and colour discrimination thresholds on young adults that weekly consume alcoholic beverages without clinical concerns. Twenty-four young adults were evaluated by an ophthalmologist and performed three psychophysical tests to evaluate their vision functions. We estimated the spatial luminance contrast sensitivity function at 11 spatial frequencies ranging from 0.1 to 30 cycles/degree. No difference in contrast sensitivity was observed comparing alcohol consumers and control subjects. For the evaluation of colour vision, we used the Farnsworth-Munsell 100 hue test (FM 100 test to test subject's ability to perform a colour arrangement task and the Mollon-Reffin test (MR test to measure subject's colour discrimination thresholds. Alcohol consumers made more mistakes than controls in the FM100 test, and their mistakes were diffusely distributed in the FM colour space without any colour axis preference. Alcohol consumers also performed worse than controls in the MR test and had higher colour discrimination thresholds compared to controls around three different reference points of a perceptually homogeneous colour space, the CIE 1976 chromaticity diagram. There was no colour axis preference in the threshold elevation observed among alcoholic subjects. Young adult weekly alcohol consumers showed subclinical colour vision losses with preservation of spatial luminance contrast sensitivity. Adolescence and young adult age are periods of important neurological development and alcohol exposure during this period of life might be responsible for deficits in visual functions, especially colour vision that is very sensitive to

  9. Vision and laterality: does occlusion disclose a feedback processing advantage for the right hand system?

    Science.gov (United States)

    Buekers, M J; Helsen, W F

    2000-09-01

    The main purpose of this study was to examine whether manual asymmetries could be related to the superiority of the left hemisphere/right hand system in processing visual feedback. Subjects were tested when performing single (Experiment 1) and reciprocal (Experiment 2) aiming movements under different vision conditions (full vision, 20 ms on/180 ms off, 10/90, 40/160, 20/80, 60/120, 20/40). Although in both experiments right hand advantages were found, manual asymmetries did not interact with intermittent vision conditions. Similar patterns of results were found across vision conditions for both hands. These data do not support the visual feedback processing hypothesis of manual asymmetry. Motor performance is affected to the same extent for both hand systems when vision is degraded.

  10. Research for VISION 2020

    Directory of Open Access Journals (Sweden)

    Peter Ackland

    2010-12-01

    Full Text Available We need good quality information to be able to carry out our eye care programmes in support of VISION 2020, to measure (and improve our performance, and to advocate for the resources and support we need to succeed. Much of this information can be collected, analysed, and used as part of our daily work, as many of the articles in this issue show.

  11. Low Vision Devices and Training

    Directory of Open Access Journals (Sweden)

    Imran Azam Butt

    2004-01-01

    Full Text Available Vision is the ability to see with a clear perception of detail, colour and contrast, and to distinguish objects visually. Like any other sense, vision tends to deteriorate or diminish naturally with age. In most cases, reduction in visual capability can be corrected with glasses, medicine or surgery. However, if the visual changes occur because of an incurable eye disease, condition or injury, vision loss can be permanent. Many people around the world with permanent visual impairment have some residual vision which can be used with the help of low vision services, materials and devices. This paper describes different options for the enhancement of residual vision including optical and non-optical devices and providing training for the low vision client.

  12. Research on robot navigation vision sensor based on grating projection stereo vision

    Science.gov (United States)

    Zhang, Xiaoling; Luo, Yinsheng; Lin, Yuchi; Zhu, Lei

    2016-10-01

    A novel visual navigation method based on grating projection stereo vision for mobile robot in dark environment is proposed. This method is combining with grating projection profilometry of plane structured light and stereo vision technology. It can be employed to realize obstacle detection, SLAM (Simultaneous Localization and Mapping) and vision odometry for mobile robot navigation in dark environment without the image match in stereo vision technology and without phase unwrapping in the grating projection profilometry. First, we research the new vision sensor theoretical, and build geometric and mathematical model of the grating projection stereo vision system. Second, the computational method of 3D coordinates of space obstacle in the robot's visual field is studied, and then the obstacles in the field is located accurately. The result of simulation experiment and analysis shows that this research is useful to break the current autonomous navigation problem of mobile robot in dark environment, and to provide the theoretical basis and exploration direction for further study on navigation of space exploring robot in the dark and without GPS environment.

  13. Intraoperative digital angiography: Peripheral vascular applications

    International Nuclear Information System (INIS)

    Bell, K.; Reifsteck, J.E.; Binet, E.F.; Fleisher, H.J.

    1986-01-01

    Intraoperative digital angiography is the procedure of choice for the peripheral vascular surgeon who wishes to evaluate his results before terminating anesthesia. Two operating suites at the John L. McClellan Memorial Veterans Hospital are equipped with permanent ceiling-mounted Philips C-arm fluoroscopes and share an ADAC 4100 digital angiographic system. In the last 18 months, 40 peripheral vascular intraoperative digital angiographic procedures have been performed, in all but two cases using direct arterial puncture. In 65% of cases, the intraoperative study showed no significant abnormality. In 12.5%, minor abnormalities not requiring reoperation were seen. In 22.5% of cases, the intraoperative digital angiogram revealed a significant abnormality requiring immediate operative revision. None of the patients who underwent reoperation experienced postoperative sequelae. Intraoperative digital angiography is useful in identifying complications of peripheral vascular operations

  14. An Integrated Calibration Technique for Stereo Vision Systems (PREPRINT)

    Science.gov (United States)

    2010-03-01

    technique for stereo vision systems has been developed. To demonstrate and evaluate this calibration technique, multiple Wii Remotes (Wiimotes) from Nintendo ...from Nintendo were used to form stereo vision systems to perform 3D motion capture in real time. This integrated technique is a two-step process...Wiimotes) used in Nintendo Wii games. Many researchers have successfully dealt with the problem of camera calibration by taking images from a 2D

  15. Chemicals Industry Vision

    Energy Technology Data Exchange (ETDEWEB)

    none,

    1996-12-01

    Chemical industry leaders articulated a long-term vision for the industry, its markets, and its technology in the groundbreaking 1996 document Technology Vision 2020 - The U.S. Chemical Industry. (PDF 310 KB).

  16. Low Vision Tips

    Science.gov (United States)

    ... this page: https://medlineplus.gov/lowvision.html MedlinePlus: Low Vision Tips We are sorry. MedlinePlus no longer maintains the For Low Vision Users page. You will still find health resources ...

  17. Machine vision-based high-resolution weed mapping and patch-sprayer performance simulation

    NARCIS (Netherlands)

    Tang, L.; Tian, L.F.; Steward, B.L.

    1999-01-01

    An experimental machine vision-based patch-sprayer was developed. This sprayer was primarily designed to do real-time weed density estimation and variable herbicide application rate control. However, the sprayer also had the capability to do high-resolution weed mapping if proper mapping techniques

  18. Research on three-dimensional reconstruction method based on binocular vision

    Science.gov (United States)

    Li, Jinlin; Wang, Zhihui; Wang, Minjun

    2018-03-01

    As the hot and difficult issue in computer vision, binocular stereo vision is an important form of computer vision,which has a broad application prospects in many computer vision fields,such as aerial mapping,vision navigation,motion analysis and industrial inspection etc.In this paper, a research is done into binocular stereo camera calibration, image feature extraction and stereo matching. In the binocular stereo camera calibration module, the internal parameters of a single camera are obtained by using the checkerboard lattice of zhang zhengyou the field of image feature extraction and stereo matching, adopted the SURF operator in the local feature operator and the SGBM algorithm in the global matching algorithm are used respectively, and the performance are compared. After completed the feature points matching, we can build the corresponding between matching points and the 3D object points using the camera parameters which are calibrated, which means the 3D information.

  19. Power profiles of single vision and multifocal soft contact lenses.

    Science.gov (United States)

    Wagner, Sandra; Conrad, Fabian; Bakaraju, Ravi C; Fedtke, Cathleen; Ehrmann, Klaus; Holden, Brien A

    2015-02-01

    The purpose of this study was to investigate the optical zone power profile of the most commonly prescribed soft contact lenses to assess their potential impact on peripheral refractive error and hence myopia progression. The optical power profiles of six single vision and ten multifocal contact lenses of five manufacturers in the powers -1.00 D, -3.00 D, and -6.00 D were measured using the SHSOphthalmic (Optocraft GmbH, Erlangen, Germany). Instrument repeatability was also investigated. Instrument repeatability was dependent on the distance from the optical centre, manifesting unreliable data for the central 1mm of the optic zone. Single vision contact lens measurements of -6.00 D lenses revealed omafilcon A having the most negative spherical aberration, lotrafilcon A having the least. Somofilcon A had the highest minus power and lotrafilcon A the biggest deviation in positive direction, relative to their respective labelled powers. Negative spherical aberration occurred for almost all of the multifocal contact lenses, including the centre-distance designs etafilcon A bifocal and omafilcon A multifocal. Lotrafilcon B and balafilcon A seem to rely predominantly on the spherical aberration component to provide multifocality. Power profiles of single vision soft contact lenses varied greatly, many having a negative spherical aberration profile that would exacerbate myopia. Some lens types and powers are affected by large intra-batch variability or power offsets of more than 0.25 dioptres. Evaluation of power profiles of multifocal lenses was derived that provides helpful information for prescribing lenses for presbyopes and progressing myopes. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  20. Review: Familiarity to Vision Rehabilitation Process

    Directory of Open Access Journals (Sweden)

    Nasser Sadegh-Pour

    2006-10-01

    Full Text Available Considering the numbers of low vision patients who have been visited and treated in eye clinics, sometimes there is no exact treatment to increase their visual acuity. Therefore, the necessity to pay attention to vision rehabilitation for them is strongly felt. The aims of this essay are to define vision rehabilitation and its process in relevant centers (called Low Vision Clinic.The statistic of low vision people is reported and the method of collecting data is described. Standard definition, causes of low vision and related diseases (congenital, heredity, acquired… are explained. In addition, low vision aids and role of test and prescription are discussed. Sometimes ophthalmologists and optometrists can not exactly cure patient to raise their V.A because there is no treatment or drug or ordinary glasses. In these cases the clients should refer to low vision clinic and visit low vision specialist on vision rehabilitation process. After primary evaluation they are tested completely and at the end are prescribed proper low vision aid and also provided with advice in relation to career, education role and training techniques especially in children. At the last part of present dissertation, some examples are provided to show effectiveness of vision rehabilitation and low vision aid among the clients in different countries.

  1. Vasculitic peripheral neuropathy

    Directory of Open Access Journals (Sweden)

    Mona Amini

    2014-02-01

    Full Text Available Primary systemic vasculitis in pre-capillary arteries is associated with peripheral neuropathy. In some types of systematic vasculitis about 60 % of patients have peripheral nervous system (PNS involvement. In vasculitic peripheral neuropathies (VPN a necrotizing and inflammatory process leads to narrowing of vasa nervorum lumen and eventually the appearance of ischemic lesions in peripheral nerves. Some features might be suggestive of VPN, like: axonal nerve degeneration, wallerian-like degeneration, and diameter irregularity of nerve. Peripheral nervous system (PNS destruction during systemic vasculitides should be considered, due to its frequency and early occurrence in vasculitis progression. The first line treatment of non systematic VPNs is corticosteroid agents, but these drugs might worsen the VPNs or systemic vasculitis.

  2. A Vision-Based Sensor for Noncontact Structural Displacement Measurement

    Science.gov (United States)

    Feng, Dongming; Feng, Maria Q.; Ozer, Ekin; Fukuda, Yoshio

    2015-01-01

    Conventional displacement sensors have limitations in practical applications. This paper develops a vision sensor system for remote measurement of structural displacements. An advanced template matching algorithm, referred to as the upsampled cross correlation, is adopted and further developed into a software package for real-time displacement extraction from video images. By simply adjusting the upsampling factor, better subpixel resolution can be easily achieved to improve the measurement accuracy. The performance of the vision sensor is first evaluated through a laboratory shaking table test of a frame structure, in which the displacements at all the floors are measured by using one camera to track either high-contrast artificial targets or low-contrast natural targets on the structural surface such as bolts and nuts. Satisfactory agreements are observed between the displacements measured by the single camera and those measured by high-performance laser displacement sensors. Then field tests are carried out on a railway bridge and a pedestrian bridge, through which the accuracy of the vision sensor in both time and frequency domains is further confirmed in realistic field environments. Significant advantages of the noncontact vision sensor include its low cost, ease of operation, and flexibility to extract structural displacement at any point from a single measurement. PMID:26184197

  3. Head-Mounted Display Technology for Low Vision Rehabilitation and Vision Enhancement

    Science.gov (United States)

    Ehrlich, Joshua R.; Ojeda, Lauro V.; Wicker, Donna; Day, Sherry; Howson, Ashley; Lakshminarayanan, Vasudevan; Moroi, Sayoko E.

    2017-01-01

    Purpose To describe the various types of head-mounted display technology, their optical and human factors considerations, and their potential for use in low vision rehabilitation and vision enhancement. Design Expert perspective. Methods An overview of head-mounted display technology by an interdisciplinary team of experts drawing on key literature in the field. Results Head-mounted display technologies can be classified based on their display type and optical design. See-through displays such as retinal projection devices have the greatest potential for use as low vision aids. Devices vary by their relationship to the user’s eyes, field of view, illumination, resolution, color, stereopsis, effect on head motion and user interface. These optical and human factors considerations are important when selecting head-mounted displays for specific applications and patient groups. Conclusions Head-mounted display technologies may offer advantages over conventional low vision aids. Future research should compare head-mounted displays to commonly prescribed low vision aids in order to compare their effectiveness in addressing the impairments and rehabilitation goals of diverse patient populations. PMID:28048975

  4. Eyes on crowding : Crowding is preserved when responding by eye and similarly affects identity and position accuracy

    NARCIS (Netherlands)

    Yildirim, Funda; Meyer, Vincent; Cornelissen, Frans W.

    Peripheral vision guides recognition and selection of targets for eye movements. Crowding-a decline in recognition performance that occurs when a potential target is surrounded by other, similar, objects-influences peripheral object recognition. A recent model study suggests that crowding may be due

  5. Are Visual Peripheries Forever Young?

    Directory of Open Access Journals (Sweden)

    Kalina Burnat

    2015-01-01

    Full Text Available The paper presents a concept of lifelong plasticity of peripheral vision. Central vision processing is accepted as critical and irreplaceable for normal perception in humans. While peripheral processing chiefly carries information about motion stimuli features and redirects foveal attention to new objects, it can also take over functions typical for central vision. Here I review the data showing the plasticity of peripheral vision found in functional, developmental, and comparative studies. Even though it is well established that afferent projections from central and peripheral retinal regions are not established simultaneously during early postnatal life, central vision is commonly used as a general model of development of the visual system. Based on clinical studies and visually deprived animal models, I describe how central and peripheral visual field representations separately rely on early visual experience. Peripheral visual processing (motion is more affected by binocular visual deprivation than central visual processing (spatial resolution. In addition, our own experimental findings show the possible recruitment of coarse peripheral vision for fine spatial analysis. Accordingly, I hypothesize that the balance between central and peripheral visual processing, established in the course of development, is susceptible to plastic adaptations during the entire life span, with peripheral vision capable of taking over central processing.

  6. Are visual peripheries forever young?

    Science.gov (United States)

    Burnat, Kalina

    2015-01-01

    The paper presents a concept of lifelong plasticity of peripheral vision. Central vision processing is accepted as critical and irreplaceable for normal perception in humans. While peripheral processing chiefly carries information about motion stimuli features and redirects foveal attention to new objects, it can also take over functions typical for central vision. Here I review the data showing the plasticity of peripheral vision found in functional, developmental, and comparative studies. Even though it is well established that afferent projections from central and peripheral retinal regions are not established simultaneously during early postnatal life, central vision is commonly used as a general model of development of the visual system. Based on clinical studies and visually deprived animal models, I describe how central and peripheral visual field representations separately rely on early visual experience. Peripheral visual processing (motion) is more affected by binocular visual deprivation than central visual processing (spatial resolution). In addition, our own experimental findings show the possible recruitment of coarse peripheral vision for fine spatial analysis. Accordingly, I hypothesize that the balance between central and peripheral visual processing, established in the course of development, is susceptible to plastic adaptations during the entire life span, with peripheral vision capable of taking over central processing.

  7. Postural steadiness and ankle force variability in peripheral neuropathy

    Science.gov (United States)

    Paxton, Roger J.; Feldman-Kothe, Caitlin; Trabert, Megan K.; Hitchcock, Leah N.; Reiser, Raoul F.; Tracy, Brian L.

    2015-01-01

    Introduction The purpose was to determine the effect of peripheral neuropathy (PN) on motor output variability for ankle muscles of older adults, and the relation between ankle motor variability and postural stability in PN patients. Methods Older adults with (O-PN) and without PN (O), and young adults (Y) underwent assessment of standing postural stability and ankle muscle force steadiness. Results O-PN displayed impaired ankle muscle force control and postural stability compared with O and Y groups. For O-PN, the amplitude of plantarflexor force fluctuations was moderately correlated with postural stability under no-vision conditions (r = 0.54, P = 0.01). Discussion The correlation of variations in ankle force with postural stability in PN suggests a contribution of ankle muscle dyscontrol to the postural instability that impacts physical function for older adults with PN. PMID:26284897

  8. An FPGA Implementation of a Robot Control System with an Integrated 3D Vision System

    Directory of Open Access Journals (Sweden)

    Yi-Ting Chen

    2015-05-01

    Full Text Available Robot decision making and motion control are commonly based on visual information in various applications. Position-based visual servo is a technique for vision-based robot control, which operates in the 3D workspace, uses real-time image processing to perform tasks of feature extraction, and returns the pose of the object for positioning control. In order to handle the computational burden at the vision sensor feedback, we design a FPGA-based motion-vision integrated system that employs dedicated hardware circuits for processing vision processing and motion control functions. This research conducts a preliminary study to explore the integration of 3D vision and robot motion control system design based on a single field programmable gate array (FPGA chip. The implemented motion-vision embedded system performs the following functions: filtering, image statistics, binary morphology, binary object analysis, object 3D position calculation, robot inverse kinematics, velocity profile generation, feedback counting, and multiple-axes position feedback control.

  9. Learning from vision-to-touch is different than from touch-to-vision.

    Directory of Open Access Journals (Sweden)

    Dagmar A Wismeijer

    2012-11-01

    Full Text Available We studied whether vision can teach touch to the same extent as touch seems to teach vision. In a 2 x 2 between-participants learning study, we artificially correlated visual gloss cues with haptic compliance cues. In two "natural" tasks, we tested whether visual gloss estimations have an influence on haptic estimations of softness and vice versa. In two "new" tasks, in which participants were either asked to haptically judge glossiness or to visually judge softness, we investigated how perceptual estimates transfer from one sense to the other. Our results showed that vision does not teach touch as efficient as touch seems to teach vision.

  10. Colombia, mining country. Vision a year 2019

    International Nuclear Information System (INIS)

    2006-01-01

    Scope of the state action for the mining sector, the performance of the mining sector, regional perceptions of mining development, construction of a long-term vision for the mining sector, the action plan and goals follow-up

  11. IDENTIFICATION OF MARKS ON TIRES USING ARTIFICIAL VISION FOR QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    André P. Dias

    2015-03-01

    Full Text Available Tire inspection is presently done by workers who have as their main problems, besides identifying the defects, the time available for defect identification and the inherent costs. Companies can become more sustainable by adopting automated methods to perform such type of processes, such as artificial vision, with advantages both in the processing time and in the incurred costs. This paper addresses the development of an artificial vision system that aims to be an asset in the field of tyre inspection, having as main characteristics its execution speed and its reliability. The conjugation of these criteria is a prerequisite for this system to be able to be integrated in inspection machines. The paper focusses on the study of three image processing methods to be used in the identification of marks (red dots on tires. In this work was used the free Open Computer Vision artificial vision library to process the images acquired by a Basler matrix camera. Two different techniques, namely Background Subtraction and Hough Transform, were tested to implement the solution. After developing the artificial vision inspection application, tests were made to measure the performance of both methods and the results were promising: processing time was low and, simultaneous, the achieved accuracy is high.

  12. Oculocutaneous albinism: identifying and overcoming barriers to vision care in a Nigerian population.

    Science.gov (United States)

    Udeh, N N; Eze, B I; Onwubiko, S N; Arinze, O C; Onwasigwe, E N; Umeh, R E

    2014-06-01

    To assess eye care service utilization, and identify access barriers in a south-eastern Nigerian albino population. The study was a population-based, cross-sectional survey conducted in Enugu state between August, 2011 and January, 2012. Using the data base of the state's Albino Foundation and tailored awareness creation, persons living with albinism were identified and recruited at two study centres. Data on participants' socio-demographics, perception of vision, visual needs, previous eye examination and or low vision assessment, use of glasses or low vision devices were collected. Reasons for non-utilisation of available vision care services were also obtained. Descriptive and comparative statistics were performed. A p low vision assessment and none--0.0% had used low vision device. Of the participants, 82.4% reported previous eye examination, 33.3% had not used spectacles previously, despite the existing need. Ignorance--88.9% and poor access--8.5% were the main barriers to uptake of vision care services. In Enugu, Nigeria, there is poor awareness and low utilization of vision care services among people with albinism. The identified barriers to vision care access are amenable to awareness creation and logistic change in the provision of appropriate vision care services.

  13. Governing through visions : Evaluating the performativity of the European gas target models

    NARCIS (Netherlands)

    Dignum, M.; Correlje, A.F.; Groenleer, Martijn; Scholten, D.J.

    2017-01-01

    In 2010 an initiative was launched to realize a competitive single EU market for natural gas through the use of a future vision. This Gas Target Model (GTM) aimed to provide direction for concrete market development through regulatory structures as well as an overarching scope of what a

  14. Synthetic and Enhanced Vision Systems for NextGen (SEVS) Simulation and Flight Test Performance Evaluation

    Science.gov (United States)

    Shelton, Kevin J.; Kramer, Lynda J.; Ellis,Kyle K.; Rehfeld, Sherri A.

    2012-01-01

    The Synthetic and Enhanced Vision Systems for NextGen (SEVS) simulation and flight tests are jointly sponsored by NASA's Aviation Safety Program, Vehicle Systems Safety Technology project and the Federal Aviation Administration (FAA). The flight tests were conducted by a team of Honeywell, Gulfstream Aerospace Corporation and NASA personnel with the goal of obtaining pilot-in-the-loop test data for flight validation, verification, and demonstration of selected SEVS operational and system-level performance capabilities. Nine test flights (38 flight hours) were conducted over the summer and fall of 2011. The evaluations were flown in Gulfstream.s G450 flight test aircraft outfitted with the SEVS technology under very low visibility instrument meteorological conditions. Evaluation pilots flew 108 approaches in low visibility weather conditions (600 ft to 2400 ft visibility) into various airports from Louisiana to Maine. In-situ flight performance and subjective workload and acceptability data were collected in collaboration with ground simulation studies at LaRC.s Research Flight Deck simulator.

  15. Peripheral biomarkers revisited: integrative profiling of peripheral samples for psychiatric research.

    Science.gov (United States)

    Hayashi-Takagi, Akiko; Vawter, Marquis P; Iwamoto, Kazuya

    2014-06-15

    Peripheral samples, such as blood and skin, have been used for decades in psychiatric research as surrogates for central nervous system samples. Although the validity of the data obtained from peripheral samples has been questioned and other state-of-the-art techniques, such as human brain imaging, genomics, and induced pluripotent stem cells, seem to reduce the value of peripheral cells, accumulating evidence has suggested that revisiting peripheral samples is worthwhile. Here, we re-evaluate the utility of peripheral samples and argue that establishing an understanding of the common signaling and biological processes in the brain and peripheral samples is required for the validity of such models. First, we present an overview of the available types of peripheral cells and describe their advantages and disadvantages. We then briefly summarize the main achievements of omics studies, including epigenome, transcriptome, proteome, and metabolome analyses, as well as the main findings of functional cellular assays, the results of which imply that alterations in neurotransmission, metabolism, the cell cycle, and the immune system may be partially responsible for the pathophysiology of major psychiatric disorders such as schizophrenia. Finally, we discuss the future utility of peripheral samples for the development of biomarkers and tailor-made therapies, such as multimodal assays that are used as a battery of disease and trait pathways and that might be potent and complimentary tools for use in psychiatric research. © 2013 Society of Biological Psychiatry Published by Society of Biological Psychiatry All rights reserved.

  16. Sensory feedback by peripheral nerve stimulation improves task performance in individuals with upper limb loss using a myoelectric prosthesis.

    Science.gov (United States)

    Schiefer, Matthew; Tan, Daniel; Sidek, Steven M; Tyler, Dustin J

    2016-02-01

    Tactile feedback is critical to grip and object manipulation. Its absence results in reliance on visual and auditory cues. Our objective was to assess the effect of sensory feedback on task performance in individuals with limb loss. Stimulation of the peripheral nerves using implanted cuff electrodes provided two subjects with sensory feedback with intensity proportional to forces on the thumb, index, and middle fingers of their prosthetic hand during object manipulation. Both subjects perceived the sensation on their phantom hand at locations corresponding to the locations of the forces on the prosthetic hand. A bend sensor measured prosthetic hand span. Hand span modulated the intensity of sensory feedback perceived on the thenar eminence for subject 1 and the middle finger for subject 2. We performed three functional tests with the blindfolded subjects. First, the subject tried to determine whether or not a wooden block had been placed in his prosthetic hand. Second, the subject had to locate and remove magnetic blocks from a metal table. Third, the subject performed the Southampton Hand Assessment Procedure (SHAP). We also measured the subject's sense of embodiment with a survey and his self-confidence. Blindfolded performance with sensory feedback was similar to sighted performance in the wooden block and magnetic block tasks. Performance on the SHAP, a measure of hand mechanical function and control, was similar with and without sensory feedback. An embodiment survey showed an improved sense of integration of the prosthesis in self body image with sensory feedback. Sensory feedback by peripheral nerve stimulation improved object discrimination and manipulation, embodiment, and confidence. With both forms of feedback, the blindfolded subjects tended toward results obtained with visual feedback.

  17. Low Vision Rehabilitation and Diabetic Retinopathy

    International Nuclear Information System (INIS)

    Khan, Sarfaraz A.

    2007-01-01

    Diabetic retinopathy is emerging as a major cause of blindness. Diabetic retinopathy calls for a multidisciplinary to the patients. Management of the patient requires a team work by the internist, diabetologist, dietician, ophthalmologist and low vision therapist. Diabetic retinopathy very often results in vision loss. It is important for ophthalmologist to recognize the importance of low vision rehabilitation in formulating appropriate treatment strategies. People with low vision loss due to diabetic retinopathy usually experience difficulty in daily life. Most people with diabetic retinopathy (who have remaining useful vision) can be helped with low vision devices. However, often one low vision device may not be suitable for all purposes. A comprehensive low vision evaluation is required to assess the person's current visual status, identify the goals and the visual needs, and then design an individualized vision rehabilitation program to meet these needs. (author)

  18. Summary receiver operating characteristic curves as a technique for meta-analysis of the diagnostic performance of duplex ultrasonography in peripheral arterial disease

    NARCIS (Netherlands)

    deVries, SO; Hunink, MGM; Polak, JF

    Rationale and Objectives. We summarized and compared the diagnostic performance of duplex and color-guided duplex ultrasonography in the evaluation of peripheral arterial disease. We present our research as an example of the use of summary receiver operating characteristic (ROC) curves in a

  19. Intermittent pneumatic leg compressions enhance muscle performance and blood flow in a model of peripheral arterial insufficiency.

    Science.gov (United States)

    Roseguini, Bruno T; Arce-Esquivel, Arturo A; Newcomer, Sean C; Yang, Hsiao T; Terjung, Ronald; Laughlin, M H

    2012-05-01

    Despite the escalating prevalence in the aging population, few therapeutic options exist to treat patients with peripheral arterial disease. Application of intermittent pneumatic leg compressions (IPC) is regarded as a promising noninvasive approach to treat this condition, but the clinical efficacy, as well the mechanistic basis of action of this therapy, remain poorly defined. We tested the hypothesis that 2 wk of daily application of IPC enhances exercise tolerance by improving blood flow and promoting angiogenesis in skeletal muscle in a model of peripheral arterial insufficiency. Male Sprague-Dawley rats were subjected to bilateral ligation of the femoral artery and randomly allocated to treatment or sham groups. Animals were anesthetized daily and exposed to 1-h sessions of bilateral IPC or sham treatment for 14-16 consecutive days. A third group of nonligated rats was also studied. Marked increases in treadmill exercise tolerance (∼33%, P < 0.05) and improved muscle performance in situ (∼10%, P < 0.05) were observed in IPC-treated animals. Compared with sham-treated controls, blood flow measured with isotope-labeled microspheres during in situ contractions tended to be higher in IPC-treated animals in muscles composed of predominantly fast-twitch white fibers, such as the plantaris (∼93%, P = 0.02). Capillary contacts per fiber and citrate synthase activity were not significantly altered by IPC treatment. Collectively, these data indicate that IPC improves exercise tolerance in a model of peripheral arterial insufficiency in part by enhancing blood flow to collateral-dependent tissues.

  20. The Influence of Attentional Focus Instructions and Vision on Jump Height Performance

    Science.gov (United States)

    Abdollahipour, Reza; Psotta, Rudolf; Land, William M.

    2016-01-01

    Purpose: Studies have suggested that the use of visual information may underlie the benefit associated with an external focus of attention. Recent studies exploring this connection have primarily relied on motor tasks that involve manipulation of an object (object projection). The present study examined whether vision influences the effect of…

  1. Role of optometry school in single day large scale school vision testing

    Science.gov (United States)

    Anuradha, N; Ramani, Krishnakumar

    2015-01-01

    Background: School vision testing aims at identification and management of refractive errors. Large-scale school vision testing using conventional methods is time-consuming and demands a lot of chair time from the eye care professionals. A new strategy involving a school of optometry in single day large scale school vision testing is discussed. Aim: The aim was to describe a new approach of performing vision testing of school children on a large scale in a single day. Materials and Methods: A single day vision testing strategy was implemented wherein 123 members (20 teams comprising optometry students and headed by optometrists) conducted vision testing for children in 51 schools. School vision testing included basic vision screening, refraction, frame measurements, frame choice and referrals for other ocular problems. Results: A total of 12448 children were screened, among whom 420 (3.37%) were identified to have refractive errors. 28 (1.26%) children belonged to the primary, 163 to middle (9.80%), 129 (4.67%) to secondary and 100 (1.73%) to the higher secondary levels of education respectively. 265 (2.12%) children were referred for further evaluation. Conclusion: Single day large scale school vision testing can be adopted by schools of optometry to reach a higher number of children within a short span. PMID:25709271

  2. Property-driven functional verification technique for high-speed vision system-on-chip processor

    Science.gov (United States)

    Nshunguyimfura, Victor; Yang, Jie; Liu, Liyuan; Wu, Nanjian

    2017-04-01

    The implementation of functional verification in a fast, reliable, and effective manner is a challenging task in a vision chip verification process. The main reason for this challenge is the stepwise nature of existing functional verification techniques. This vision chip verification complexity is also related to the fact that in most vision chip design cycles, extensive efforts are focused on how to optimize chip metrics such as performance, power, and area. Design functional verification is not explicitly considered at an earlier stage at which the most sound decisions are made. In this paper, we propose a semi-automatic property-driven verification technique. The implementation of all verification components is based on design properties. We introduce a low-dimension property space between the specification space and the implementation space. The aim of this technique is to speed up the verification process for high-performance parallel processing vision chips. Our experimentation results show that the proposed technique can effectively improve the verification effort up to 20% for the complex vision chip design while reducing the simulation and debugging overheads.

  3. Management of peripheral polypoidal choroidal vasculopathy with intravitreal bevacizumab and indocyanine green angiography-guided laser photocoagulation

    Directory of Open Access Journals (Sweden)

    Pukhraj Rishi

    2012-01-01

    Full Text Available A 69-year-old lady presented with complaints of decreased vision in left eye since one month. Best Corrected Visual Acuity (BCVA was 6/18 in that eye. Fundus examination revealed non-central geographic atrophy and soft drusens at macula in both eyes. Temporal periphery of left eye revealed subretinal exudates with altered sub-RPE hemorrhage mimicking peripheral exudative hemorrhagic chorioretinopathy (PEHCR. Fundus Fluorescein Angiogram showed window defects at macula and blocked fluorescence at temporal periphery in left eye. However, Indocyanine green angiography (ICGA revealed active peripheral choroidal polyps. The patient was successfully treated with intravitreal bevacizumab and ICGA-guided laser photocoagulation. 27 months after laser treatment, BCVA improved to 6/9. Rationale of consecutive anti-vascular endothelial growth factor (VEGF treatment followed by more definitive laser photocoagulation is that anti-VEGF aids in resolution of subretinal fluid, thus making the polyp more amenable to focal laser photocoagulation which stabilizes the choroidal vasculature and prevents further leakage.

  4. Ping-Pong Robotics with High-Speed Vision System

    DEFF Research Database (Denmark)

    Li, Hailing; Wu, Haiyan; Lou, Lei

    2012-01-01

    The performance of vision-based control is usually limited by the low sampling rate of the visual feedback. We address Ping-Pong robotics as a widely studied example which requires high-speed vision for highly dynamic motion control. In order to detect a flying ball accurately and robustly...... of the manipulator are updated iteratively with decreasing error. Experiments are conducted on a 7 degrees of freedom humanoid robot arm. A successful Ping-Pong playing between the robot arm and human is achieved with a high successful rate of 88%....

  5. Synthetic vision to augment sensor based vision for remotely piloted vehicles

    NARCIS (Netherlands)

    Tadema, J.; Koeners, J.; Theunissen, E.

    2006-01-01

    In the past fifteen years, several research programs have demonstrated potential advantages of synthetic vision technology for manned aviation. More recently, some research programs have focused on integrating synthetic vision technology into control stations for remotely controlled aircraft. The

  6. What You Should Know (Low Vision)

    Science.gov (United States)

    ... Cataract Diabetic retinopathy Glaucoma Macular degeneration What is low vision? When you have low vision, eyeglasses, contact lenses, ... eyesight. How do I know if I have low vision? Below are some signs of low vision. Even ...

  7. Peripheral reactions

    International Nuclear Information System (INIS)

    Greiner, D.

    1978-01-01

    Peripheral collisions, that is, collisions involving a small amount of overlap of nuclear matter, are discussed including inclusive interactions, the magnitude of the peripheral cross section, fragmentation, a compilation of experiments and available data, limiting fragmentation, factorization, some models, fragment momentum distributions, and future research directions

  8. AstroCV: Astronomy computer vision library

    Science.gov (United States)

    González, Roberto E.; Muñoz, Roberto P.; Hernández, Cristian A.

    2018-04-01

    AstroCV processes and analyzes big astronomical datasets, and is intended to provide a community repository of high performance Python and C++ algorithms used for image processing and computer vision. The library offers methods for object recognition, segmentation and classification, with emphasis in the automatic detection and classification of galaxies.

  9. Exploration of a Vision for Actor Database Systems

    DEFF Research Database (Denmark)

    Shah, Vivek

    of these services. Existing popular approaches to building these services either use an in-memory database system or an actor runtime. We observe that these approaches have complementary strengths and weaknesses. In this dissertation, we propose the integration of actor programming models in database systems....... In doing so, we lay down a vision for a new class of systems called actor database systems. To explore this vision, this dissertation crystallizes the notion of an actor database system by defining its feature set in light of current application and hardware trends. In order to explore the viability...... of the outlined vision, a new programming model named Reactors has been designed to enrich classic relational database programming models with logical actor programming constructs. To support the reactor programming model, a high-performance in-memory multi-core OLTP database system named REACTDB has been built...

  10. Protyping machine vision software on the World Wide Web

    Science.gov (United States)

    Karantalis, George; Batchelor, Bruce G.

    1998-10-01

    Interactive image processing is a proven technique for analyzing industrial vision applications and building prototype systems. Several of the previous implementations have used dedicated hardware to perform the image processing, with a top layer of software providing a convenient user interface. More recently, self-contained software packages have been devised and these run on a standard computer. The advent of the Java programming language has made it possible to write platform-independent software, operating over the Internet, or a company-wide Intranet. Thus, there arises the possibility of designing at least some shop-floor inspection/control systems, without the vision engineer ever entering the factories where they will be used. It successful, this project will have a major impact on the productivity of vision systems designers.

  11. Assessment of functional vision and its rehabilitation.

    Science.gov (United States)

    Colenbrander, August

    2010-03-01

    This article, based on a report prepared for the International Council of Ophthalmology (ICO) and the International Society for Low Vision Research and Rehabilitation (ISLRR), explores the assessment of various aspects of visual functioning as needed to document the outcomes of vision rehabilitation. Documenting patient abilities and functional vision (how the person functions) is distinct from the measurement of visual functions (how the eye functions) and also from the assessment of quality of life. All three areas are important, but their assessment should not be mixed. Observation of task performance offers the most objective measure of functional vision, but it is time-consuming and not feasible for many tasks. Where possible, timing and error rates provide an easy score. Patient response questionnaires provide an alternative. They may save time and can cover a wider area, but the responses are subjective and proper scoring presents problems. Simple Likert scoring still predominates but Rasch analysis, needed to provide better result scales, is gaining ground. Selection of questions is another problem. If the range of difficulties does not match the range of patient abilities, and if the difficulties are not distributed evenly, the results are not optimal. This may be an argument to use different outcome questions for different conditions. Generic questionnaires are appropriate for the assessment of generic quality of life, but not for specific rehabilitation outcomes. Different questionnaires are also needed for screening, intake and outcomes. Intake questions must be relevant to actual needs to allow prioritization of rehabilitation goals; the activity inventory presents a prototype. Outcome questions should be targeted at predefined rehabilitation goals. The Appendix cites some promising examples. The Low Vision Intervention Trial (LOVIT) is an example of a properly designed randomized control study, and has demonstrated the remarkable effectiveness of

  12. Ocular problems of computer vision syndrome: Review

    Directory of Open Access Journals (Sweden)

    Ayakutty Muni Raja

    2015-01-01

    Full Text Available Nowadays, ophthalmologists are facing a new group of patients having eye problems related to prolonged and excessive computer use. When the demand for near work exceeds the normal ability of the eye to perform the job comfortably, one develops discomfort and prolonged exposure, which leads to a cascade of reactions that can be put together as computer vision syndrome (CVS. In India, the computer-using population is more than 40 million, and 80% have discomfort due to CVS. Eye strain, headache, blurring of vision and dryness are the most common symptoms. Workstation modification, voluntary blinking, adjustment of the brightness of screen and breaks in between can reduce CVS.

  13. Vision Problems in Homeless Children.

    Science.gov (United States)

    Smith, Natalie L; Smith, Thomas J; DeSantis, Diana; Suhocki, Marissa; Fenske, Danielle

    2015-08-01

    Vision problems in homeless children can decrease educational achievement and quality of life. To estimate the prevalence and specific diagnoses of vision problems in children in an urban homeless shelter. A prospective series of 107 homeless children and teenagers who underwent screening with a vision questionnaire, eye chart screening (if mature enough) and if vision problem suspected, evaluation by a pediatric ophthalmologist. Glasses and other therapeutic interventions were provided if necessary. The prevalence of vision problems in this population was 25%. Common diagnoses included astigmatism, amblyopia, anisometropia, myopia, and hyperopia. Glasses were required and provided for 24 children (22%). Vision problems in homeless children are common and frequently correctable with ophthalmic intervention. Evaluation by pediatric ophthalmologist is crucial for accurate diagnoses and treatment. Our system of screening and evaluation is feasible, efficacious, and reproducible in other homeless care situations.

  14. Genetics Home Reference: color vision deficiency

    Science.gov (United States)

    ... my area? Other Names for This Condition color blindness color vision defects defective color vision vision defect, color ... Perception KidsHealth from the Nemours Foundation MalaCards: color blindness MalaCards: color vision deficiency Orphanet: Blue cone monochromatism Orphanet: NON ...

  15. Obstacle detection by stereo vision of fast correlation matching

    International Nuclear Information System (INIS)

    Jeon, Seung Hoon; Kim, Byung Kook

    1997-01-01

    Mobile robot navigation needs acquiring positions of obstacles in real time. A common method for performing this sensing is through stereo vision. In this paper, indoor images are acquired by binocular vision, which contains various shapes of obstacles. From these stereo image data, in order to obtain distances to obstacles, we must deal with the correspondence problem, or get the region in the other image corresponding to the projection of the same surface region. We present an improved correlation matching method enhancing the speed of arbitrary obstacle detection. The results are faster, simple matching, robustness to noise, and improvement of precision. Experimental results under actual surroundings are presented to reveal the performance. (author)

  16. Reading aids for adults with low vision

    Science.gov (United States)

    Virgili, Gianni; Acosta, Ruthy; Grover, Lori L; Bentley, Sharon A; Giacomelli, Giovanni

    2014-01-01

    Background The purpose of low-vision rehabilitation is to allow people to resume or to continue to perform daily living tasks, with reading being one of the most important. This is achieved by providing appropriate optical devices and special training in the use of residual-vision and low-vision aids, which range from simple optical magnifiers to high-magnification video magnifiers. Objectives To assess the effects of reading aids for adults with low vision. Search methods We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2013, Issue 1), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE, (January 1950 to January 2013), EMBASE (January 1980 to January 2013), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to January 2013), OpenGrey (System for Information on Grey Literature in Europe) (www.opengrey.eu/), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov/) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 31 January 2013. We searched the reference lists of relevant articles and used the Science Citation Index to find articles that cited the included studies and contacted investigators and manufacturers of low-vision aids. We handsearched the British Journal of Visual Impairment from 1983 to 1999 and the Journal of Visual Impairment and Blindness from 1976 to 1991. Selection criteria This review includes randomised and quasi-randomised trials in which any device or aid used for reading had been compared to another device or aid in people aged 16 or over with low vision as defined by the study investigators. Data collection and analysis At least two authors independently

  17. Learning from vision-to-touch is different than learning from touch-to-vision.

    Science.gov (United States)

    Wismeijer, Dagmar A; Gegenfurtner, Karl R; Drewing, Knut

    2012-01-01

    We studied whether vision can teach touch to the same extent as touch seems to teach vision. In a 2 × 2 between-participants learning study, we artificially correlated visual gloss cues with haptic compliance cues. In two "natural" tasks, we tested whether visual gloss estimations have an influence on haptic estimations of softness and vice versa. In two "novel" tasks, in which participants were either asked to haptically judge glossiness or to visually judge softness, we investigated how perceptual estimates transfer from one sense to the other. Our results showed that vision does not teach touch as efficient as touch seems to teach vision.

  18. The peripheral artery questionnaire: a new disease-specific health status measure for patients with peripheral arterial disease.

    Science.gov (United States)

    Spertus, John; Jones, Philip; Poler, Sherri; Rocha-Singh, Krishna

    2004-02-01

    The most common indication for treating patients with peripheral arterial disease is to improve their health status: their symptoms, function, and quality of life. Quantifying health status requires a valid, reproducible, and sensitive disease-specific measure. The Peripheral Artery Questionnaire (PAQ) is a 20-item questionnaire developed to meet this need by quantifying patients' physical limitations, symptoms, social function, treatment satisfaction, and quality of life. Psychometric and clinical properties of the PAQ were evaluated in a prospective cohort study of 44 patients undergoing elective percutaneous peripheral revascularization. To establish reproducibility, 2 assessments were performed 2 weeks apart and before revascularization. The change in scores before and 6 weeks after revascularization were used to determine the instruments' responsiveness and were compared with the Short Form-36 and the Walking Impairment Questionnaire. A series of cross-sectional analyses were performed to establish the construct validity of the PAQ. The 7 domains of the PAQ were internally reliable, with Cronbach alpha = 0.80 to 0.94. The test-retest reliability analyses revealed insignificant mean changes of 0.6 to 2.3 points (P = not significant for all). Conversely, the change after revascularization ranged from 13.7 to 41.9 points (P PAQ to clinical improvement. The PAQ Summary Scale was the most sensitive of all scales tested. Construct validity was established by demonstrating correlations with other measures of patient health status. The PAQ is a valid, reliable, and responsive disease-specific measure for patients with peripheral arterial disease. It may prove to be a useful end point in clinical trials and a potential aid in disease management.

  19. Sensory feedback by peripheral nerve stimulation improves task performance in individuals with upper limb loss using a myoelectric prosthesis

    Science.gov (United States)

    Schiefer, Matthew; Tan, Daniel; Sidek, Steven M.; Tyler, Dustin J.

    2016-02-01

    Objective. Tactile feedback is critical to grip and object manipulation. Its absence results in reliance on visual and auditory cues. Our objective was to assess the effect of sensory feedback on task performance in individuals with limb loss. Approach. Stimulation of the peripheral nerves using implanted cuff electrodes provided two subjects with sensory feedback with intensity proportional to forces on the thumb, index, and middle fingers of their prosthetic hand during object manipulation. Both subjects perceived the sensation on their phantom hand at locations corresponding to the locations of the forces on the prosthetic hand. A bend sensor measured prosthetic hand span. Hand span modulated the intensity of sensory feedback perceived on the thenar eminence for subject 1 and the middle finger for subject 2. We performed three functional tests with the blindfolded subjects. First, the subject tried to determine whether or not a wooden block had been placed in his prosthetic hand. Second, the subject had to locate and remove magnetic blocks from a metal table. Third, the subject performed the Southampton Hand Assessment Procedure (SHAP). We also measured the subject’s sense of embodiment with a survey and his self-confidence. Main results. Blindfolded performance with sensory feedback was similar to sighted performance in the wooden block and magnetic block tasks. Performance on the SHAP, a measure of hand mechanical function and control, was similar with and without sensory feedback. An embodiment survey showed an improved sense of integration of the prosthesis in self body image with sensory feedback. Significance. Sensory feedback by peripheral nerve stimulation improved object discrimination and manipulation, embodiment, and confidence. With both forms of feedback, the blindfolded subjects tended toward results obtained with visual feedback.

  20. IDA's Energy Vision 2050

    DEFF Research Database (Denmark)

    Mathiesen, Brian Vad; Lund, Henrik; Hansen, Kenneth

    IDA’s Energy Vision 2050 provides a Smart Energy System strategy for a 100% renewable Denmark in 2050. The vision presented should not be regarded as the only option in 2050 but as one scenario out of several possibilities. With this vision the Danish Society of Engineers, IDA, presents its third...... contribution for an energy strategy for Denmark. The IDA’s Energy Plan 2030 was prepared in 2006 and IDA’s Climate Plan was prepared in 2009. IDA’s Energy Vision 2050 is developed for IDA by representatives from The Society of Engineers and by a group of researchers at Aalborg University. It is based on state......-of-the-art knowledge about how low cost energy systems can be designed while also focusing on long-term resource efficiency. The Energy Vision 2050 has the ambition to focus on all parts of the energy system rather than single technologies, but to have an approach in which all sectors are integrated. While Denmark...

  1. Panoramic stereo sphere vision

    Science.gov (United States)

    Feng, Weijia; Zhang, Baofeng; Röning, Juha; Zong, Xiaoning; Yi, Tian

    2013-01-01

    Conventional stereo vision systems have a small field of view (FOV) which limits their usefulness for certain applications. While panorama vision is able to "see" in all directions of the observation space, scene depth information is missed because of the mapping from 3D reference coordinates to 2D panoramic image. In this paper, we present an innovative vision system which builds by a special combined fish-eye lenses module, and is capable of producing 3D coordinate information from the whole global observation space and acquiring no blind area 360°×360° panoramic image simultaneously just using single vision equipment with one time static shooting. It is called Panoramic Stereo Sphere Vision (PSSV). We proposed the geometric model, mathematic model and parameters calibration method in this paper. Specifically, video surveillance, robotic autonomous navigation, virtual reality, driving assistance, multiple maneuvering target tracking, automatic mapping of environments and attitude estimation are some of the applications which will benefit from PSSV.

  2. Causes of low vision and blindness in rural Indonesia

    Science.gov (United States)

    Saw, S-M; Husain, R; Gazzard, G M; Koh, D; Widjaja, D; Tan, D T H

    2003-01-01

    Aim: To determine the prevalence rates and major contributing causes of low vision and blindness in adults in a rural setting in Indonesia Methods: A population based prevalence survey of adults 21 years or older (n=989) was conducted in five rural villages and one provincial town in Sumatra, Indonesia. One stage household cluster sampling procedure was employed where 100 households were randomly selected from each village or town. Bilateral low vision was defined as habitual VA (measured using tumbling “E” logMAR charts) in the better eye worse than 6/18 and 3/60 or better, based on the WHO criteria. Bilateral blindness was defined as habitual VA worse than 3/60 in the better eye. The anterior segment and lens of subjects with low vision or blindness (both unilateral and bilateral) (n=66) were examined using a portable slit lamp and fundus examination was performed using indirect ophthalmoscopy. Results: The overall age adjusted (adjusted to the 1990 Indonesia census population) prevalence rate of bilateral low vision was 5.8% (95% confidence interval (CI) 4.2 to 7.4) and bilateral blindness was 2.2% (95% CI 1.1 to 3.2). The rates of low vision and blindness increased with age. The major contributing causes for bilateral low vision were cataract (61.3%), uncorrected refractive error (12.9%), and amblyopia (12.9%), and the major cause of bilateral blindness was cataract (62.5%). The major causes of unilateral low vision were cataract (48.0%) and uncorrected refractive error (12.0%), and major causes of unilateral blindness were amblyopia (50.0%) and trauma (50.0%). Conclusions: The rates of habitual low vision and blindness in provincial Sumatra, Indonesia, are similar to other developing rural countries in Asia. Blindness is largely preventable, as the major contributing causes (cataract and uncorrected refractive error) are amenable to treatment. PMID:12928268

  3. Vision-Related Quality of Life Associated with Unilateral and Bilateral Ocular Conditions.

    Science.gov (United States)

    Brown, Gary C; Brown, Melissa M; Stein, Joshua D; Smiddy, William E

    2018-02-21

    To present ophthalmic patient time-tradeoff vision utilities for quantifying vision-related quality-of-life when the fellow eye still has good vision. These utilities are important for performing reliable cost-utility analyses. Consecutive time-tradeoff vision utilities were obtained from ophthalmic patients with good vision (20/20-20/25) in one eye and vision ranging from 20/20 to no light perception in the fellow eye over a 15-year period from 2000 through 2014. Five hundred eighty-six ophthalmic participant interviews from Wills Eye Hospital, New York Eye and Ear Hospital, and ophthalmology office practices in Pennsylvania and New Jersey. Participants underwent a full ophthalmic examination, after which time-tradeoff vision utilities were obtained by personal interview by the authors using a standardized, validated instrument. Time-tradeoff vision utilities. Mean time-tradeoff vision utilities were as follows in participants with good vision (20/20-20/25) in at least one eye and the following visions in the fellow eyes: no light perception, 0.79; counting fingers to light perception, 0.87; 20/200 to 20/400, 0.88; 20/60 to 20/100, 0.88; 20/30 to 20/50, 0.87; and 20/20 to 20/25, 0.94. In people with good vision (20/20-20/25) in one eye, the associated mean time-tradeoff vision utility is a remarkably consistent 0.87 to 0.88 when vision in the fellow eye ranges from 20/30 to light perception. Vision of 20/20 to 20/25 in the fellow eye results in a significantly higher associated utility of 0.94 (P vision of no light perception in the fellow eye results in a significantly lower utility of 0.079 (P < 0.01). These utilities are important for calculating reliable patient value (quality-adjusted life-year) gains in ophthalmic cost-utility analysis populations in which there is unilateral and bilateral disease involvement. Copyright © 2018 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  4. FPGA Vision Data Architecture

    Science.gov (United States)

    Morfopoulos, Arin C.; Pham, Thang D.

    2013-01-01

    JPL has produced a series of FPGA (field programmable gate array) vision algorithms that were written with custom interfaces to get data in and out of each vision module. Each module has unique requirements on the data interface, and further vision modules are continually being developed, each with their own custom interfaces. Each memory module had also been designed for direct access to memory or to another memory module.

  5. Assessment of Laparoscopic Skills Performance: 2D Versus 3D Vision and Classic Instrument Versus New Hand-Held Robotic Device for Laparoscopy.

    Science.gov (United States)

    Leite, Mariana; Carvalho, Ana F; Costa, Patrício; Pereira, Ricardo; Moreira, Antonio; Rodrigues, Nuno; Laureano, Sara; Correia-Pinto, Jorge; Vilaça, João L; Leão, Pedro

    2016-02-01

    Laparoscopic surgery has undeniable advantages, such as reduced postoperative pain, smaller incisions, and faster recovery. However, to improve surgeons' performance, ergonomic adaptations of the laparoscopic instruments and introduction of robotic technology are needed. The aim of this study was to ascertain the influence of a new hand-held robotic device for laparoscopy (HHRDL) and 3D vision on laparoscopic skills performance of 2 different groups, naïve and expert. Each participant performed 3 laparoscopic tasks-Peg transfer, Wire chaser, Knot-in 4 different ways. With random sequencing we assigned the execution order of the tasks based on the first type of visualization and laparoscopic instrument. Time to complete each laparoscopic task was recorded and analyzed with one-way analysis of variance. Eleven experts and 15 naïve participants were included. Three-dimensional video helps the naïve group to get better performance in Peg transfer, Wire chaser 2 hands, and Knot; the new device improved the execution of all laparoscopic tasks (P < .05). For expert group, the 3D video system benefited them in Peg transfer and Wire chaser 1 hand, and the robotic device in Peg transfer, Wire chaser 1 hand, and Wire chaser 2 hands (P < .05). The HHRDL helps the execution of difficult laparoscopic tasks, such as Knot, in the naïve group. Three-dimensional vision makes the laparoscopic performance of the participants without laparoscopic experience easier, unlike those with experience in laparoscopic procedures. © The Author(s) 2015.

  6. A Pilot Evaluation of On-Road Detection Performance by Drivers with Hemianopia Using Oblique Peripheral Prisms

    Directory of Open Access Journals (Sweden)

    Alex R. Bowers

    2012-01-01

    Full Text Available Aims. Homonymous hemianopia (HH, a severe visual consequence of stroke, causes difficulties in detecting obstacles on the nonseeing (blind side. We conducted a pilot study to evaluate the effects of oblique peripheral prisms, a novel development in optical treatments for HH, on detection of unexpected hazards when driving. Methods. Twelve people with complete HH (median 49 years, range 29–68 completed road tests with sham oblique prism glasses (SP and real oblique prism glasses (RP. A masked evaluator rated driving performance along the 25 km routes on busy streets in Ghent, Belgium. Results. The proportion of satisfactory responses to unexpected hazards on the blind side was higher in the RP than the SP drive (80% versus 30%; P=0.001, but similar for unexpected hazards on the seeing side. Conclusions. These pilot data suggest that oblique peripheral prisms may improve responses of people with HH to blindside hazards when driving and provide the basis for a future, larger-sample clinical trial. Testing responses to unexpected hazards in areas of heavy vehicle and pedestrian traffic appears promising as a real-world outcome measure for future evaluations of HH rehabilitation interventions aimed at improving detection when driving.

  7. Vision and kinesthesis in spatial short-term memory.

    Science.gov (United States)

    Podros, L Z; Wyke, M A; Waters, J M

    1981-10-01

    This investigation examined the effects of different localizing cues on the precision with which subjects can recall the position of a target in space. The availability of the cues--vision, kinesthesis, or both--was varied during both learning and recall. Subjects (age range 26 to 58 yr.) placed the stimulus or watched it being placed. The stimulus was removed, and subjects replaced or indicated its replacement location. Results show a striking similarity of performance for all subjects and significant performance differences relative to the different cues. The results provide information about intramodal and intermodal visual and kinesthetic transfer effects and about the effects of unimodal and multimodal input in such transfer. Results confirm a dominance of vision over kinesthesis, i.e., "kinesthetic memory" does not provide as accurate localizing information as does "visual memory."

  8. Peripheral Developing Odontoma or Peripheral Ameloblastic Fibroodontoma: A Rare Challenging Case

    Directory of Open Access Journals (Sweden)

    Saede Atarbashi Moghadam

    2016-01-01

    Full Text Available Peripheral odontogenic lesions are considered to be rare within the classification of odontogenic tumors. They share the same microscopic characteristics of their central counterparts. Here, we report an ulcerated mass of the maxillary gingiva that on histopathological examination was diagnosed as peripheral developing odontoma or peripheral ameloblastic fibroodontoma. The diagnosis of this tumor is challenging and may lead to unnecessary treatment.

  9. Modeling foveal vision

    NARCIS (Netherlands)

    Florack, L.M.J.; Sgallari, F.; Murli, A.; Paragios, N.

    2007-01-01

    geometric model is proposed for an artificial foveal vision system, and its plausibility in the context of biological vision is explored. The model is based on an isotropic, scale invariant two-form that describes the spatial layout of receptive fields in the the visual sensorium (in the biological

  10. A Real-Time Embedded System for Stereo Vision Preprocessing Using an FPGA

    DEFF Research Database (Denmark)

    Kjær-Nielsen, Anders; Jensen, Lars Baunegaard With; Sørensen, Anders Stengaard

    2008-01-01

    In this paper a low level vision processing node for use in existing IEEE 1394 camera setups is presented. The processing node is a small embedded system, that utilizes an FPGA to perform stereo vision preprocessing at rates limited by the bandwidth of IEEE 1394a (400Mbit). The system is used...

  11. Peripheral Neuropathy and Agent Orange

    Science.gov (United States)

    ... Enter ZIP code here Enter ZIP code here Peripheral Neuropathy and Agent Orange VA presumes Veterans' early-onset ... 10 percent disabling by VA's rating regulations. About peripheral neuropathy Peripheral neuropathy is a condition of the peripheral ...

  12. Impact of low vision services on the quality of life of low vision patients in Ghana

    Directory of Open Access Journals (Sweden)

    Godwin O. Ovenseri-Ogbomo

    2016-03-01

    Full Text Available Patients’ perspectives on the impact of clinical interventions have been recognised as critical elements in patient care. Quality-of-life instruments are designed to measure these perspectives. We used the National Eye Institute’s 25-item Visual Function Questionnaire (NEI VFQ to measure the impact of optical low vision devices on the quality of life of 22 low vision patients who obtained and were using low vision devices from a secondary low vision clinic in the Eastern Region, Ghana. The study employed a pre- and post-intervention technique. We found statistically significant improvements in measured visual acuity and NEI VFQ scores in 8 of the 10 domains evaluated. We conclude that optical low vision devices have a positive impact on the quality of life of low vision patients in Ghana. Keywords: low vision; quality of life; visual acuity; visual impairment; Ghana

  13. Industrial vision

    DEFF Research Database (Denmark)

    Knudsen, Ole

    1998-01-01

    This dissertation is concerned with the introduction of vision-based application s in the ship building industry. The industrial research project is divided into a natural seq uence of developments, from basic theoretical projective image generation via CAD and subpixel analysis to a description...... is present ed, and the variability of the parameters is examined and described. The concept of using CAD together with vision information is based on the fact that all items processed at OSS have an associated complete 3D CAD model that is accessible at all production states. This concept gives numerous...... possibilities for using vision in applications which otherwise would be very difficult to automate. The requirement for low tolerances in production is, despite the huge dimensions of the items involved, extreme. This fact makes great demands on the ability to do robust sub pixel estimation. A new method based...

  14. Vision screening with the RDE stereotest in pediatric populations.

    Science.gov (United States)

    Schmidt, P P

    1994-04-01

    The usefulness of the Random Dot E (RDE) stereotest in screening the vision of school-aged children for vision problems has been established. As a single screening procedure, the effectivity (phi) of the RDE (phi = +0.52) is greater than the widely used Snellen acuity technique (phi = +0.36) and faster to complete. Very-low-birthweight (VLBW) children have a higher incidence of vision problems including strabismus, amblyopia, and refractive error than children born with normal-birthweights (NBW's). My purpose was to determine: (1) whether a group of young children at high risk for vision problems could perform random dot stereotesting and (2) an age appropriate pass/fail criterion for stereoacuity screening. Furthermore, categorization as pass or fail by each screening method studied [stereoacuity (RDE), visual acuity [Teller Acuity Cards (TAC) and Broken Wheel (BWA)] and refractive error] was compared for independent agreement with vision examination results. The subjects were a cohort of NBW and VLBW) (RDE); 81.2%, 64.3% (TAC); 52.9%, 92.3% (BWA); and 94.1%, 61.5% (refractive error), respectively, (3) the reliability the RDE stereoacuity screening was greater (k = +0.66) than any of the other procedures studied, and (4) there was 73.3% agreement on test-retest categorizations between observers.(ABSTRACT TRUNCATED AT 250 WORDS)

  15. Accounting for standard errors of vision-specific latent trait in regression models.

    Science.gov (United States)

    Wong, Wan Ling; Li, Xiang; Li, Jialiang; Wong, Tien Yin; Cheng, Ching-Yu; Lamoureux, Ecosse L

    2014-07-11

    To demonstrate the effectiveness of Hierarchical Bayesian (HB) approach in a modeling framework for association effects that accounts for SEs of vision-specific latent traits assessed using Rasch analysis. A systematic literature review was conducted in four major ophthalmic journals to evaluate Rasch analysis performed on vision-specific instruments. The HB approach was used to synthesize the Rasch model and multiple linear regression model for the assessment of the association effects related to vision-specific latent traits. The effectiveness of this novel HB one-stage "joint-analysis" approach allows all model parameters to be estimated simultaneously and was compared with the frequently used two-stage "separate-analysis" approach in our simulation study (Rasch analysis followed by traditional statistical analyses without adjustment for SE of latent trait). Sixty-six reviewed articles performed evaluation and validation of vision-specific instruments using Rasch analysis, and 86.4% (n = 57) performed further statistical analyses on the Rasch-scaled data using traditional statistical methods; none took into consideration SEs of the estimated Rasch-scaled scores. The two models on real data differed for effect size estimations and the identification of "independent risk factors." Simulation results showed that our proposed HB one-stage "joint-analysis" approach produces greater accuracy (average of 5-fold decrease in bias) with comparable power and precision in estimation of associations when compared with the frequently used two-stage "separate-analysis" procedure despite accounting for greater uncertainty due to the latent trait. Patient-reported data, using Rasch analysis techniques, do not take into account the SE of latent trait in association analyses. The HB one-stage "joint-analysis" is a better approach, producing accurate effect size estimations and information about the independent association of exposure variables with vision-specific latent traits

  16. Reconfigurable On-Board Vision Processing for Small Autonomous Vehicles

    Directory of Open Access Journals (Sweden)

    James K. Archibald

    2006-12-01

    Full Text Available This paper addresses the challenge of supporting real-time vision processing on-board small autonomous vehicles. Local vision gives increased autonomous capability, but it requires substantial computing power that is difficult to provide given the severe constraints of small size and battery-powered operation. We describe a custom FPGA-based circuit board designed to support research in the development of algorithms for image-directed navigation and control. We show that the FPGA approach supports real-time vision algorithms by describing the implementation of an algorithm to construct a three-dimensional (3D map of the environment surrounding a small mobile robot. We show that FPGAs are well suited for systems that must be flexible and deliver high levels of performance, especially in embedded settings where space and power are significant concerns.

  17. Reconfigurable On-Board Vision Processing for Small Autonomous Vehicles

    Directory of Open Access Journals (Sweden)

    Fife WadeS

    2007-01-01

    Full Text Available This paper addresses the challenge of supporting real-time vision processing on-board small autonomous vehicles. Local vision gives increased autonomous capability, but it requires substantial computing power that is difficult to provide given the severe constraints of small size and battery-powered operation. We describe a custom FPGA-based circuit board designed to support research in the development of algorithms for image-directed navigation and control. We show that the FPGA approach supports real-time vision algorithms by describing the implementation of an algorithm to construct a three-dimensional (3D map of the environment surrounding a small mobile robot. We show that FPGAs are well suited for systems that must be flexible and deliver high levels of performance, especially in embedded settings where space and power are significant concerns.

  18. Company Vision and Organizational Learning

    Directory of Open Access Journals (Sweden)

    Vojko Toman

    2015-11-01

    Full Text Available The effectiveness of a company is largely dependent on the company itself; it depends above all on its corporate governance, management, and implementation, as well as on decision-making processes and coordination. Many authors believe that organizational learning and knowledge are the most relevant aspects of company effectiveness. If a company wants to be effective it needs to create and realize its vision; to do this, it needs creativity, imagination, and knowledge, which can be obtained or enhanced through learning. This paper defines vision, learning, creativity and management and, above all, their relationships. The author argues that company vision influences the learning and knowledge of employees in the company through the vision’s content, through the vision-creating process, and through the vision enforcement process. Conversely, the influence of learning on company vision is explained. The paper is aimed at the use in the practice of companies and helps them to increase their effectiveness.

  19. Predictors of functional vision changes after cataract surgery: the PROVISION study.

    Science.gov (United States)

    Chaudhary, Varun; Popovic, Marko; Holmes, Julie; Robinson, Tammy; Mak, Michael; Mohaghegh P, S Mohammad; Eino, Dalia; Mann, Keith; Kobetz, Lawrence; Gusenbauer, Kaela; Barbosa, Joshua

    2016-08-01

    To ascertain whether time-to-treatment, sex, age, preoperative functional vision scores, education, and ocular comorbidities predict change in functional vision pre- to postoperatively in patients receiving cataract surgery. Prospective cohort study. Three hundred and forty-three cataract patients at the Hamilton Regional Eye Institute. Participants 18 years or older scheduled to undergo cataract surgery completed the Catquest-9SF functional vision questionnaire on the day of their surgery and were mailed a survey 2-3 months postoperatively. Multivariate linear regression was used to determine the ability of predictors to explain variability in functional vision change between questionnaire administrations. One hundred and sixty-six patients completed both baseline and follow-up questionnaires. Mean age of the cohort was 73.8 ± 8.1 years. Most patients were female (59.6%), had cataract surgery performed for the first time (66.9%), and had spent a mean time of 20.3 ± 20.7 weeks waiting for surgery. Functional vision improved in 83.7% of patients. The mean baseline Catquest-9SF score was the only significant predictor of functional vision improvement (adjusted R(2) = 0.47; F1,159 = 144.6; p functional vision improved by 0.74 logits when mean baseline survey score increased by 1 logit. In most patients, functional vision improved after cataract surgery. Mean baseline Catquest-9SF score was a moderate predictor of the observed improvement. Copyright © 2016 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  20. Understanding and preventing computer vision syndrome.

    Science.gov (United States)

    Loh, Ky; Redd, Sc

    2008-01-01

    The invention of computer and advancement in information technology has revolutionized and benefited the society but at the same time has caused symptoms related to its usage such as ocular sprain, irritation, redness, dryness, blurred vision and double vision. This cluster of symptoms is known as computer vision syndrome which is characterized by the visual symptoms which result from interaction with computer display or its environment. Three major mechanisms that lead to computer vision syndrome are extraocular mechanism, accommodative mechanism and ocular surface mechanism. The visual effects of the computer such as brightness, resolution, glare and quality all are known factors that contribute to computer vision syndrome. Prevention is the most important strategy in managing computer vision syndrome. Modification in the ergonomics of the working environment, patient education and proper eye care are crucial in managing computer vision syndrome.

  1. UNDERSTANDING AND PREVENTING COMPUTER VISION SYNDROME

    Directory of Open Access Journals (Sweden)

    REDDY SC

    2008-01-01

    Full Text Available The invention of computer and advancement in information technology has revolutionized and benefited the society but at the same time has caused symptoms related to its usage such as ocular sprain, irritation, redness, dryness, blurred vision and double vision. This cluster of symptoms is known as computer vision syndrome which is characterized by the visual symptoms which result from interaction with computer display or its environment. Three major mechanisms that lead to computer vision syndrome are extraocular mechanism, accommodative mechanism and ocular surface mechanism. The visual effects of the computer such as brightness, resolution, glare and quality all are known factors that contribute to computer vision syndrome. Prevention is the most important strategy in managing computer vision syndrome. Modification in the ergonomics of the working environment, patient education and proper eye care are crucial in managing computer vision syndrome.

  2. Autophagy and phagocytosis converge for better vision.

    Science.gov (United States)

    Ferguson, Thomas A; Green, Douglas R

    2014-01-01

    The retinal pigment epithelium (RPE) is a single layer of nonregenerating cells essential to homeostasis in the retina and the preservation of vision. While the RPE perform a number of important functions, 2 essential processes are phagocytosis, which removes the most distal tips of the photoreceptors to support disk renewal, and the visual cycle, which maintains the supply of chromophore for regeneration of photo-bleached visual pigments. We recently reported that these processes are linked by a noncanonical form of autophagy termed LC3-associated phagocytosis (LAP) in which components of the autophagy pathway are co-opted by phagocytosis to recover vitamin A in support of optimal vision. Here we summarize these findings.

  3. [Quality system Vision 2000].

    Science.gov (United States)

    Pasini, Evasio; Pitocchi, Oreste; de Luca, Italo; Ferrari, Roberto

    2002-12-01

    A recent document of the Italian Ministry of Health points out that all structures which provide services to the National Health System should implement a Quality System according to the ISO 9000 standards. Vision 2000 is the new version of the ISO standard. Vision 2000 is less bureaucratic than the old version. The specific requests of the Vision 2000 are: a) to identify, to monitor and to analyze the processes of the structure, b) to measure the results of the processes so as to ensure that they are effective, d) to implement actions necessary to achieve the planned results and the continual improvement of these processes, e) to identify customer requests and to measure customer satisfaction. Specific attention should be also dedicated to the competence and training of the personnel involved in the processes. The principles of the Vision 2000 agree with the principles of total quality management. The present article illustrates the Vision 2000 standard and provides practical examples of the implementation of this standard in cardiological departments.

  4. Isolated effects of peripheral arm and central body cooling on arm performance.

    Science.gov (United States)

    Giesbrecht, G G; Wu, M P; White, M D; Johnston, C E; Bristow, G K

    1995-10-01

    Whole body cooling impairs manual arm performance. The independent contributions of local (peripheral) and/or whole body (central) cooling are not known. Therefore, a protocol was developed in which the arm and the rest of the body could be independently cooled. Biceps temperature (Tmus), at a depth of 20 mm, and esophageal temperature (Tes) were measured. Six subjects were immersed to the clavicles in a tank (body tank) of water under 3 conditions: 1) cold body-cold arm (CB-CA); 2) warm body-cold arm (WB-CA); and 3) cold body-warm arm (CB-WA). In the latter two conditions, subjects placed their dominant arm in a separate (arm) tank. Water temperature (Tw) in each tank was independently controlled. In conditions requiring cold body and/or cold arm, Tw in the appropriate tanks was 8 degrees C. In conditions requiring warm body and/or warm arm, Tw in the appropriate tanks was adjusted between 29 and 38 degrees C to maintain body/arm temperature at baseline values. A battery of 6 tests, requiring fine or gross motor movements, were performed immediately before immersion and after 15, 45, and 70 minutes of immersion. In CB-CA, Tes decreased from an average of 37.2 to 35.6 degrees C and Tmus decreased from 34.6 to 22.0 degrees C. In WB-CA, Tmus decreased to 18.1 degrees C (Tes = 37.1 degrees C), and in CB-WA, Tes decreased to 35.8 degrees C (Tmus = 34.5 degrees C). By the end of immersion, there were significant decrements (43-85%) in the performance of all tests in CB-CA and WB-CA (p body and/or the arm elicits large decrements in finger, hand and arm performance. The decrements are due almost entirely to the local effects of arm tissue cooling.

  5. Do reading additions improve reading in pre-presbyopes with low vision?

    Science.gov (United States)

    Alabdulkader, Balsam; Leat, Susan

    2012-09-01

    This study compared three different methods of determining a reading addition and the possible improvement on reading performance in children and young adults with low vision. Twenty-eight participants with low vision, aged 8 to 32 years, took part in the study. Reading additions were determined with (a) a modified Nott dynamic retinoscopy, (b) a subjective method, and (c) an age-based formula. Reading performance was assessed with MNREAD-style reading charts at 12.5 cm, with and without each reading addition in random order. Outcome measures were reading speed, critical print size, MNREAD threshold, and the area under the reading speed curve. For the whole group, there was no significant improvement in reading performance with any of the additions. When participants with normal accommodation at 12.5 cm were excluded, the area under the reading speed curve was significantly greater with all reading additions compared with no addition (p = 0.031, 0.028, and 0.028, respectively). Also, the reading acuity threshold was significantly better with all reading additions compared with no addition (p = 0.014, 0.030, and 0.036, respectively). Distance and near visual acuity, age, and contrast sensitivity did not predict improvement with a reading addition. All, but one, of the participants who showed a significant improvement in reading with an addition had reduced accommodation. A reading addition may improve reading performance for young people with low vision and should be considered as part of a low vision assessment, particularly when accommodation is reduced.

  6. Peripheral regional anaesthesia and outcome: lessons learned from the last 10 years

    NARCIS (Netherlands)

    Kessler, J.; Marhofer, P.; Hopkins, P. M.; Hollmann, M. W.

    2015-01-01

    Our aim was to review the recent evidence for the efficacy of peripheral regional anaesthesia. Following a systematic literature search and selection of publications based on prospectively agreed upon criteria, we produced a narrative review of the most commonly performed peripheral regional

  7. [Comparison of the Pressure on the Larynx and Tongue Using McGRATH® MAC Video Laryngoscope--Direct Vision versus Indirect Vision].

    Science.gov (United States)

    Tanaka, Yasutomo; Miyazaki, Yukiko; Kitakata, Hidenori; Shibuya, Hiromi; Okada, Toshiki

    2015-12-01

    Studies show that McGRATH® MAC (McG) is useful during direct laryngoscopy. However, no study has examined whether McG re- duces pressure on the upper airway tract We compared direct vision with indirect vision concerning pressure on the larynx and tongue. Twenty two anesthesiologists and 16 junior residents attempted direct laryngoscopy of airway management simulator using McG with direct vision and indirect vision. Pressure was measured using pressure measurement film. In anesthesiologists group, pressure on larynx was 14.8 ± 2.7 kgf · cm(-2) with direct vision and 12.7 ± 2.7 kgf · cm(-2) with indirect vision (P vision and 7.6 ± 2.8 kgf · cm(-2) with indirect vision (P = 0.18). In junior residents group, pressure on larynx was 19.0 ± 1.3 kgf · cm(-2) with direct vision and 14.1 ± 3.1 kgf · cm(-2) with indirect vision (P vision and 11.2 ± 4.7 kgf · cm(-2) with indirect vision (P vision can reduce pressure on the upper airway tract.

  8. Vision in laboratory rodents-Tools to measure it and implications for behavioral research.

    Science.gov (United States)

    Leinonen, Henri; Tanila, Heikki

    2017-07-29

    Mice and rats are nocturnal mammals and their vision is specialized for detection of motion and contrast in dim light conditions. These species possess a large proportion of UV-sensitive cones in their retinas and the majority of their optic nerve axons target superior colliculus rather than visual cortex. Therefore, it was a widely held belief that laboratory rodents hardly utilize vision during day-time behavior. This dogma is being questioned as accumulating evidence suggests that laboratory rodents are able to perform complex visual functions, such as perceiving subjective contours, and that declined vision may affect their performance in many behavioral tasks. For instance, genetic engineering may have unexpected consequences on vision as mouse models of Alzheimer's and Huntington's diseases have declined visual function. Rodent vision can be tested in numerous ways using operant training or reflex-based behavioral tasks, or alternatively using electrophysiological recordings. In this article, we will first provide a summary of visual system and explain its characteristics unique to rodents. Then, we present well-established techniques to test rodent vision, with an emphasis on pattern vision: visual water test, optomotor reflex test, pattern electroretinography and pattern visual evoked potentials. Finally, we highlight the importance of visual phenotyping in rodents. As the number of genetically engineered rodent models and volume of behavioral testing increase simultaneously, the possibility of visual dysfunctions needs to be addressed. Neglect in this matter potentially leads to crude biases in the field of neuroscience and beyond. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Vision-based vehicle detection and tracking algorithm design

    Science.gov (United States)

    Hwang, Junyeon; Huh, Kunsoo; Lee, Donghwi

    2009-12-01

    The vision-based vehicle detection in front of an ego-vehicle is regarded as promising for driver assistance as well as for autonomous vehicle guidance. The feasibility of vehicle detection in a passenger car requires accurate and robust sensing performance. A multivehicle detection system based on stereo vision has been developed for better accuracy and robustness. This system utilizes morphological filter, feature detector, template matching, and epipolar constraint techniques in order to detect the corresponding pairs of vehicles. After the initial detection, the system executes the tracking algorithm for the vehicles. The proposed system can detect front vehicles such as the leading vehicle and side-lane vehicles. The position parameters of the vehicles located in front are obtained based on the detection information. The proposed vehicle detection system is implemented on a passenger car, and its performance is verified experimentally.

  10. 78 FR 20376 - Qualification of Drivers; Exemption Applications; Vision

    Science.gov (United States)

    2013-04-04

    ... professional opinion, I feel like this patient is visually able to drive a commercial motor vehicle.'' Mr... his visual function, I think he has sufficient vision to perform the tasks required to operate the... visually capable of performing driving tasks required to operate a commercial vehicle.'' Mr. Roy reported...

  11. Vision enhanced navigation for unmanned systems

    Science.gov (United States)

    Wampler, Brandon Loy

    A vision based simultaneous localization and mapping (SLAM) algorithm is evaluated for use on unmanned systems. SLAM is a technique used by a vehicle to build a map of an environment while concurrently keeping track of its location within the map, without a priori knowledge. The work in this thesis is focused on using SLAM as a navigation solution when global positioning system (GPS) service is degraded or temporarily unavailable. Previous work on unmanned systems that lead up to the determination that a better navigation solution than GPS alone is first presented. This previous work includes control of unmanned systems, simulation, and unmanned vehicle hardware testing. The proposed SLAM algorithm follows the work originally developed by Davidson et al. in which they dub their algorithm MonoSLAM [1--4]. A new approach using the Pyramidal Lucas-Kanade feature tracking algorithm from Intel's OpenCV (open computer vision) library is presented as a means of keeping correct landmark correspondences as the vehicle moves through the scene. Though this landmark tracking method is unusable for long term SLAM due to its inability to recognize revisited landmarks, as opposed to the Scale Invariant Feature Transform (SIFT) and Speeded Up Robust Features (SURF), its computational efficiency makes it a good candidate for short term navigation between GPS position updates. Additional sensor information is then considered by fusing INS and GPS information into the SLAM filter. The SLAM system, in its vision only and vision/IMU form, is tested on a table top, in an open room, and finally in an outdoor environment. For the outdoor environment, a form of the slam algorithm that fuses vision, IMU, and GPS information is tested. The proposed SLAM algorithm, and its several forms, are implemented in C++ using an Extended Kalman Filter (EKF). Experiments utilizing a live video feed from a webcam are performed. The different forms of the filter are compared and conclusions are made on

  12. Diffusion-weighted MRI in prostatic lesions: Diagnostic performance of normalized ADC using normal peripheral prostatic zone as a reference

    Directory of Open Access Journals (Sweden)

    Tamer F. Taha Ali

    2018-03-01

    Full Text Available Aim of study: Evaluate the potential value of the normal peripheral zone as a reference organ to normalize prostatic lesion apparent diffusion coefficient (ADC to improve its evaluation of prostatic lesions. Patients and methods: This prospective study included 38 patients with clinical suspicion of cancer prostate (increased PSA levels (>4 ng/ml, hard prostate in digital rectal examination and who are scheduled to undergo a TRUS-guided biopsy. Conventional and DW-MRI was done and ADC was calculated. The normalized ADC value was calculated by dividing the ADC of lesion by ADC of reference site (healthy peripheral zone. DWI-MRI results were compared to the results of biopsy. Comparison of ADCs and nADCs of benign and malignant lesions was done. Receiver operating characteristics (ROC curve analysis was done. Results: The patients were classified by histopathology into non-malignant group (16 patients and malignant group (22 patients. Significant negative correlation between ADC and normalized ADC (nADC and malignancy was detected. There was no significant difference between the mean ADC of peripheral health prostatic zones (PZ between benign and malignant cases (2.221 ± 0.356 versus 1.99 ± 0.538x10−3 mm2/sec, p = 0.144.There was significant difference between the mean ADC and mean nADC in benign and malignant lesions (1.049 ± 0.217 versus 0.659 ± 0.221x10−3 mm2/sec, p < 0.001 and (0.475 ± 0.055 versus 0.328 ± 0.044, p < 0.001 respectively.There was significant higher diagnostic performance of nADC than ADC with ADC Cut-off value 0.75 × 10−3 mm2/sec and nADC cut-off value 0.39 could significantly differentiate between benign and malignant lesion with sensitivity, specificity, PPV,NPV of 86.36,75,82.61 and 80% respectively, p < 0.0001 for ADC and 95.45, 93.75, 95.45 and 93.75%, p < 0.0001 for nADC. Conclusion: diagnostic performance of nADC using normal peripheral zone is higher than

  13. Stereo Vision Inside Tire

    Science.gov (United States)

    2015-08-21

    1 Stereo Vision Inside Tire P.S. Els C.M. Becker University of Pretoria W911NF-14-1-0590 Final...Stereo Vision Inside Tire 5a. CONTRACT NUMBER W911NF-14-1-0590 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Prof PS Els CM...on the development of a stereo vision system that can be mounted inside a rolling tire , known as T2-CAM for Tire -Terrain CAMera. The T2-CAM system

  14. Copenhagen Energy Vision

    DEFF Research Database (Denmark)

    Mathiesen, Brian Vad; Lund, Rasmus Søgaard; Connolly, David

    The short-term goal for The City of Copenhagen is a CO2 neutral energy supply by the year 2025, and the long-term vision for Denmark is a 100% renewable energy (RE) supply by the year 2050. In this project, it is concluded that Copenhagen plays a key role in this transition. The long-term vision...

  15. Governance and Vision: Visions of Cities towards a low-energy future

    International Nuclear Information System (INIS)

    Pares-Ramos, Isabel K.; Dupas, Stephane

    2010-07-01

    The overall aim of this report was to identify and review the process by which different cities have built visionary plans for the long-term sustainable development of their territory for a low-energy, climate-resilient future. We used a case studies approach to describe different methods used by cities to build their visionary plans and address present energy and climate change challenges. The purpose of this report is as well to contribute to the debate on the future of cities in the post-carbon society and to inspire further initiatives for a low-energy future. The first step towards understanding the visioning/planning process of cities for a low-energy future was to identify several initiatives were cities have developed a plan or statement to address energy and climate change issues in the next 20 to 50 years. These plans and documents were then reviewed in search of diverse and innovative methods and process for visioning, design and planning towards a low-carbon future. After these preliminary assessments and observations, we selected 4 cities based on the use of different methodologies for visioning, planning and development of the action plan and projects. Afterwards, we focused on the description of the visioning/planning process per city, based on information obtained from official plans and documents, and from interviews with local authorities and other personnel working for projects in each of the cities selected. The content of the interviews varied according to the local context of the initiative, but in general contained questions regarding methods and tools used to build their visions and action plans, as well as enquiries about the visioning steps and process, the role of stakeholders, and implementation strategies used to drive forward this initiatives

  16. Computer vision and machine learning with RGB-D sensors

    CERN Document Server

    Shao, Ling; Kohli, Pushmeet

    2014-01-01

    This book presents an interdisciplinary selection of cutting-edge research on RGB-D based computer vision. Features: discusses the calibration of color and depth cameras, the reduction of noise on depth maps and methods for capturing human performance in 3D; reviews a selection of applications which use RGB-D information to reconstruct human figures, evaluate energy consumption and obtain accurate action classification; presents an approach for 3D object retrieval and for the reconstruction of gas flow from multiple Kinect cameras; describes an RGB-D computer vision system designed to assist t

  17. Evaluation and percutaneous management of atherosclerotic peripheral vascular disease

    International Nuclear Information System (INIS)

    Widlus, D.M.; Osterman, F.A. Jr.

    1989-01-01

    Atherosclerotic peripheral vascular disease (PVD) of the lower extremities deprives a person of the ability to exercise to their satisfaction, later of the ability to perform the activities of their daily life, and finally of their legs themselves. Peripheral vascular disease has long been managed by the vascular surgeon utilizing endarterectomy and peripheral arterial bypass. Patient acceptance of nonsurgical, percutaneous procedures such as percutaneous transluminal balloon angioplasty (PTA) is high. Increased utilization of these procedures has led to improved techniques and adjuncts to therapy, as well as more critical review of long-term results. This article will review the evaluation and nonoperative management of PVD, with an emphasis on the newer modalities of management presently being investigated

  18. Binary pressure-sensitive paint measurements using miniaturised, colour, machine vision cameras

    Science.gov (United States)

    Quinn, Mark Kenneth

    2018-05-01

    Recent advances in machine vision technology and capability have led to machine vision cameras becoming applicable for scientific imaging. This study aims to demonstrate the applicability of machine vision colour cameras for the measurement of dual-component pressure-sensitive paint (PSP). The presence of a second luminophore component in the PSP mixture significantly reduces its inherent temperature sensitivity, increasing its applicability at low speeds. All of the devices tested are smaller than the cooled CCD cameras traditionally used and most are of significantly lower cost, thereby increasing the accessibility of such technology and techniques. Comparisons between three machine vision cameras, a three CCD camera, and a commercially available specialist PSP camera are made on a range of parameters, and a detailed PSP calibration is conducted in a static calibration chamber. The findings demonstrate that colour machine vision cameras can be used for quantitative, dual-component, pressure measurements. These results give rise to the possibility of performing on-board dual-component PSP measurements in wind tunnels or on real flight/road vehicles.

  19. Associations between peripheral vertigo and gastroesophageal reflux disease.

    Science.gov (United States)

    Viliušytė, Edita; Macaitytė, Raminta; Vaitkus, Antanas; Rastenytė, Daiva

    2015-09-01

    We hypothesize that peripheral vertigo is associated with gastroesophageal reflux disease (GERD). Two mechanisms could be considered – gastric acids may directly irritate the respiratory mucosa and cause inflammation, or Helicobacter pylori (H. pylori) could be present and cause local infection. Reflux material (Hydrochloric acid (HCl) and pepsin) could get into the middle ear via Eustachian tube and affect osseous structures directly. Disturbance of ossicles could cause tinnitus, which is more common for peripheral vertigo. H. pylori could also get in the esophagus and in the upper respiratory tract via gastroesophageal reflux, and could cause tympanosclerosis and fixation of ossicles. In our study group, 120 of 153 (78.4%) patients had gastroesophageal reflux disease (GERD). Diagnostic tests of H. pylori (rapid urease test or blood antibody test) were performed for 96 of 120 (80%) patients with GERD and were found positive for 32 of 96 (33.3%) patients. Peripheral vertigo was present in 93 of 120 (77.6%) patients with GERD compared to 33 of 126 (26%) patients without GERD (χ(2)=9.016, p=0.003). H. pylori and peripheral vertigo coexisted in 26 of 126 patients (20.6%) (OR 1.36; 95% CI 0.49-3.74, p=0.55). Our study demonstrated statistically significant association between peripheral vertigo and GERD but not between peripheral vertigo and H. pylori. Further more extensive investigations are needed in order to explore our hypothesis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Critical care nurses' experiences of performing successful peripheral intravenous catheterization in difficult situations.

    Science.gov (United States)

    Forsberg, Angelica; Engström, Åsa

    2018-06-01

    The aim of this study is to describe the experiences of critical care nurses (CCNs) when performing successful peripheral intravenous catheterization (PIVC) on adult inpatients in difficult situations. This study uses a descriptive design with a qualitative approach. Semistructured interviews were given to CCNs (n = 22) at a general central county hospital in northern Sweden. The interview text was analyzed with qualitative thematic content analysis. Three themes emerged: "releasing time and creating peace," "feeling self-confidence in the role of expert nurse," and "technical interventions promoting success." CCNs stated that apart from experience, releasing enough time is the most crucial factor for a successful PIVC. They emphasized the importance of identifying the kinds of difficulties that may occur during the procedure, for example, fragile or/and invisible veins. CCNs explained that compared to when they were newly graduated, the difference in their approach nowadays has changed to using their hands more than their eyes and that they feel comfortable with bodily palpations. To further optimize PIVC performing skills, continued possibilities to train and learn in hospital settings are necessary, even after formal education has been completed. Copyright © 2018 Society for Vascular Nursing, Inc. Published by Elsevier Inc. All rights reserved.

  1. Functional evaluation of peripheral nerve regeneration in the rat : walking track analysis

    NARCIS (Netherlands)

    Varejao, ASP; Meek, MF; Patricio, JAB; Cabrita, AMS

    2001-01-01

    The experimental model of choice for many peripheral nerve investigators is the rat. Walking track analysis is a useful tool in the evaluation of functional peripheral nerve recovery in the rat. This quantitative method of analyzing hind limbs performance by examining footprints, known as the

  2. Drug-induced peripheral neuropathy

    DEFF Research Database (Denmark)

    Vilholm, Ole Jakob; Christensen, Alex Alban; Zedan, Ahmed

    2014-01-01

    Peripheral neuropathy can be caused by medication, and various descriptions have been applied for this condition. In this MiniReview, the term 'drug-induced peripheral neuropathy' (DIPN) is used with the suggested definition: Damage to nerves of the peripheral nervous system caused by a chemical...... substance used in the treatment, cure, prevention or diagnosis of a disease. Optic neuropathy is included in this definition. A distinction between DIPN and other aetiologies of peripheral neuropathy is often quite difficult and thus, the aim of this MiniReview is to discuss the major agents associated...

  3. Vision Sensor-Based Road Detection for Field Robot Navigation

    Directory of Open Access Journals (Sweden)

    Keyu Lu

    2015-11-01

    Full Text Available Road detection is an essential component of field robot navigation systems. Vision sensors play an important role in road detection for their great potential in environmental perception. In this paper, we propose a hierarchical vision sensor-based method for robust road detection in challenging road scenes. More specifically, for a given road image captured by an on-board vision sensor, we introduce a multiple population genetic algorithm (MPGA-based approach for efficient road vanishing point detection. Superpixel-level seeds are then selected in an unsupervised way using a clustering strategy. Then, according to the GrowCut framework, the seeds proliferate and iteratively try to occupy their neighbors. After convergence, the initial road segment is obtained. Finally, in order to achieve a globally-consistent road segment, the initial road segment is refined using the conditional random field (CRF framework, which integrates high-level information into road detection. We perform several experiments to evaluate the common performance, scale sensitivity and noise sensitivity of the proposed method. The experimental results demonstrate that the proposed method exhibits high robustness compared to the state of the art.

  4. Robotics Vision-based Heuristic Reasoning for Underwater Target Tracking and Navigation

    OpenAIRE

    Kia, Chua; Arshad, Mohd Rizal

    2006-01-01

    This paper presents a robotics vision-based heuristic reasoning system for underwater target tracking and navigation. This system is introduced to improve the level of automation of underwater Remote Operated Vehicles (ROVs) operations. A prototype which combines computer vision with an underwater robotics system is successfully designed and developed to perform target tracking and intelligent navigation. This study focuses on developing image processing algorithms and fuzzy inference system ...

  5. Molecular Detection of Neuron-Specific ELAV-Like-Positive Cells in the Peripheral Blood of Patients with Small-Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Vito D’Alessandro

    2008-01-01

    Full Text Available Background: n-ELAV (neuronal-Embryonic Lethal, Abnormal Vision-like genes belong to a family codifying for onconeural RNA-binding proteins. Anti-Hu-antibodies (anti-Hu-Ab are typically associated with paraneoplastic encephalomyelitis/sensory neuropathy (PEM/PSN, and low titres of anti-Hu-Ab, were found in newly diagnosed Small Cell Lung Cancer (SCLC. The aim of this study is to develop a sensitive and quantitative molecular real-time PCR assay to detect SCLC cells in peripheral blood (PB through nELAV-like transcripts quantification.

  6. Design and construction of automatic sorting station with machine vision

    Directory of Open Access Journals (Sweden)

    Oscar D. Velasco-Delgado

    2014-01-01

    Full Text Available This article presents the design, construction and testing of an automatic product sorting system in belt conveyor with machine vision that integrates Free and Open Source Software technology and Allen Bradley commercial equipment. Requirements are defined to determine features such as: mechanics of manufacturing station, an app of product sorting with machine vision and for automation system. For the app of machine vision a library is used for optical digital image processing Open CV, for the mechanical design of the manufacturing station is used the CAD tool Solid Edge and for the design and implementation of automation ISA standards are used along with an automation engineering project methodology integrating a PLC, an inverter, a Panel View and a DeviceNet Network. Performance tests are shown by classifying bottles and PVC pieces in four established types, the behavior of the integrated system is checked so as the efficiency of the same. The processing time on machine vision is 0.290 s on average for a piece of PVC, a capacity of 206 accessories per minute, for bottles was obtained a processing time of 0.267 s, a capacity of 224 bottles per minute. A maximum mechanical performance is obtained with 32 products per minute (1920 products/hour with the conveyor to 22 cm/s and 40 cm of distance between products obtaining an average error of 0.8%.

  7. ASCI's Vision for supercomputing future

    International Nuclear Information System (INIS)

    Nowak, N.D.

    2003-01-01

    The full text of publication follows. Advanced Simulation and Computing (ASC, formerly Accelerated Strategic Computing Initiative [ASCI]) was established in 1995 to help Defense Programs shift from test-based confidence to simulation-based confidence. Specifically, ASC is a focused and balanced program that is accelerating the development of simulation capabilities needed to analyze and predict the performance, safety, and reliability of nuclear weapons and certify their functionality - far exceeding what might have been achieved in the absence of a focused initiative. To realize its vision, ASC is creating simulation and proto-typing capabilities, based on advanced weapon codes and high-performance computing

  8. Systematic Review of Guidelines on Peripheral Artery Disease Screening

    NARCIS (Netherlands)

    Ferket, Bart S.; Spronk, Sandra; Colkesen, Ersen B.; Hunink, M. G. Myriam

    2012-01-01

    BACKGROUND: Peripheral artery disease (PAD) screening may be performed to prevent progression of PAD or future cardiovascular disease in general. Recommendations for PAD screening have to be derived indirectly because no randomized trials comparing screening versus no screening have been performed.

  9. Vision Problems and Reduced Reading Outcomes in Queensland Schoolchildren.

    Science.gov (United States)

    Hopkins, Shelley; Sampson, Geoff P; Hendicott, Peter L; Wood, Joanne M

    2017-03-01

    To assess the relationship between vision and reading outcomes in Indigenous and non-Indigenous schoolchildren to determine whether vision problems are associated with lower reading outcomes in these populations. Vision testing and reading assessments were performed on 508 Indigenous and non-Indigenous schoolchildren in Queensland, Australia divided into two age groups: Grades 1 and 2 (6-7 years of age) and Grades 6 and 7 (12-13 years of age). Vision parameters measured included cycloplegic refraction, near point of convergence, heterophoria, fusional vergence range, rapid automatized naming, and visual motor integration. The following vision conditions were then classified based on the vision findings: uncorrected hyperopia, convergence insufficiency, reduced rapid automatized naming, and delayed visual motor integration. Reading accuracy and reading comprehension were measured with the Neale reading test. The effect of uncorrected hyperopia, convergence insufficiency, reduced rapid automatized naming, and delayed visual motor integration on reading accuracy and reading comprehension were investigated with ANCOVAs. The ANCOVAs explained a significant proportion of variance in both reading accuracy and reading comprehension scores in both age groups, with 40% of the variation in reading accuracy and 33% of the variation in reading comprehension explained in the younger age group, and 27% and 10% of the variation in reading accuracy and reading comprehension, respectively, in the older age group. The vision parameters of visual motor integration and rapid automatized naming were significant predictors in all ANCOVAs (P reading results were explained by reduced visual motor integration and rapid automatized naming results. Both reduced rapid automatized naming and visual motor integration were associated with poorer reading outcomes in Indigenous and non-Indigenous children. This is an important finding given the recent emphasis placed on Indigenous children

  10. The Pedagogy of Teaching Educational Vision: A Vision Coach's Field Notes about Leaders as Learners

    Science.gov (United States)

    Schein, Jeffrey

    2009-01-01

    The emerging field of educational visioning is full of challenges and phenomena worthy of careful analysis and documentation. A relatively neglected phenomenon is the learning curve of the leaders (often lay leaders) involved in the visioning process. This article documents a range of experiences of the author serving as a vision coach to five…

  11. Vision rehabilitation interventions following mild traumatic brain injury: a scoping review.

    Science.gov (United States)

    Simpson-Jones, Mary E; Hunt, Anne W

    2018-04-10

    To broadly examine the literature to identify vision interventions following mild traumatic brain injury. Objectives are to identify: (1) evidence-informed interventions for individuals with visual dysfunction after mild traumatic brain injury; (2) professions providing these interventions; (3) gaps in the literature and areas for further research. A scoping review was conducted of four electronic databases of peer-reviewed literature from the databases earliest records to June 2017. Articles were included if the study population was mild traumatic brain injury/concussion and a vision rehabilitation intervention was tested. Two independent reviewers screened articles for inclusion, extracted data, and identified themes. The initial search identified 3111 records. Following exclusions, 22 articles were included in the final review. Nine studies evaluated optical devices, such as corrective spectacles, contact lenses, prisms, or binasal occlusion. Two studies assessed vision therapy. Ten studies examined vision therapy using optical devices. One study investigated hyperbaric oxygen therapy. Optometrists performed these interventions in most of the studies. Future research should address quality appraisal of this literature, interventions that include older adult and pediatric populations, and interdisciplinary interventions. There are promising interventions for vision deficits following mild traumatic brain injury. However, there are multiple gaps in the literature that should be addressed by future research. Implications for Rehabilitation Mild traumatic brain injury may result in visual deficits that can contribute to poor concentration, headaches, fatigue, problems reading, difficulties engaging in meaningful daily activities, and overall reduced quality of life. Promising interventions for vision rehabilitation following mild traumatic brain injury include the use of optical devices (e.g., prism glasses), vision or oculomotor therapy (e.g., targeted exercises to

  12. Helicopter blades running elevation measurement using omnidirectional vision

    Directory of Open Access Journals (Sweden)

    Chengtao CAI

    2017-12-01

    Full Text Available Omnidirectional dynamic space parameters of high-speed rotating helicopter blades are precise 3D vector description of the blades. In particular, the elevation difference is directly related to the aerodynamic performance and maneuverability of the helicopter. The state of the art detection techniques based on optics and common vision have several drawbacks, such as high demands on devices but poor extensibility, limited measurement range and fixed measurement position. In this paper, a novel approach of helicopter blades running elevation measurement is proposed based on omnidirectional vision. With the advantages of panoramic visual imaging integration, 360° field of view and rotation in-variance, high-resolution images of all rotating blades positions are obtained at one time. By studying the non-linear calibration and calculation model of omnidirectional vision system, aiming at solving the problem of inaccurate visual space mapping model, the omnidirectional and full-scale measurement of the elevation difference are finalized. Experiments are carried out on our multifunctional simulation blades test system and the practical blades test tower, respectively. The experimental results demonstrate the effectiveness of the proposed method and show that the proposed method can considerably reduce the complexity of measurement. Keywords: Full-scale measurement, Helicopter blades elevation, Non-linear calibration, Omnidirectional vision, Unified sphere model

  13. Peripheral neuropathy is associated with more frequent falls in Parkinson's disease.

    Science.gov (United States)

    Beaulieu, Mélanie L; Müller, Martijn L T M; Bohnen, Nicolaas I

    2018-04-03

    Peripheral neuropathy is a common condition in the elderly that can affect balance and gait. Postural imbalance and gait difficulties in Parkinson's disease (PD), therefore, may stem not only from the primary neurodegenerative process but also from age-related medical comorbidities. Elucidation of the effects of peripheral neuropathy on these difficulties in PD is important to provide more targeted and effective therapy. The purpose of this study was to investigate the association between lower-limb peripheral neuropathy and falls and gait performance in PD while accounting for disease-specific factors. From a total of 140 individuals with PD, 14 male participants met the criteria for peripheral neuropathy and were matched 1:1 for Hoehn & Yahr stage and duration of disease with 14 male participants without peripheral neuropathy. All participants underwent fall (retrospectively) and gait assessment, a clinical evaluation, and [ 11 C]dihydrotetrabenazine and [ 11 C]methylpiperidin-4-yl propionate PET imaging to assess dopaminergic and cholinergic denervation, respectively. The presence of peripheral neuropathy was significantly associated with more falls (50% vs. 14%, p = 0.043), as well as a shorter stride length (p = 0.011) and greater stride length variability (p = 0.004), which resulted in slower gait speed (p = 0.016) during level walking. There was no significant difference in nigrostriatal dopaminergic denervation, cortical and thalamic cholinergic denervation, and MDS-UPDRS motor examination scores between groups. Lower-limb peripheral neuropathy is significantly associated with more falls and gait difficulties in PD. Thus, treating such neuropathy may reduce falls and/or improve gait performance in PD. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Color Calibration for Colorized Vision System with Digital Sensor and LED Array Illuminator

    Directory of Open Access Journals (Sweden)

    Zhenmin Zhu

    2016-01-01

    Full Text Available Color measurement by the colorized vision system is a superior method to achieve the evaluation of color objectively and continuously. However, the accuracy of color measurement is influenced by the spectral responses of digital sensor and the spectral mismatch of illumination. In this paper, two-color vision system illuminated by digital sensor and LED array, respectively, is presented. The Polynomial-Based Regression method is applied to solve the problem of color calibration in the sRGB and CIE  L⁎a⁎b⁎ color spaces. By mapping the tristimulus values from RGB to sRGB color space, color difference between the estimated values and the reference values is less than 3ΔE. Additionally, the mapping matrix ΦRGB→sRGB has proved a better performance in reducing the color difference, and it is introduced subsequently into the colorized vision system proposed for a better color measurement. Necessarily, the printed matter of clothes and the colored ceramic tile are chosen as the application experiment samples of our colorized vision system. As shown in the experimental data, the average color difference of images is less than 6ΔE. It indicates that a better performance of color measurement is obtained via the colorized vision system proposed.

  15. Development of Vision System for Dimensional Measurement for Irradiated Fuel Assembly

    International Nuclear Information System (INIS)

    Shin, Jungcheol; Kwon, Yongbock; Park, Jongyoul; Woo, Sangkyun; Kim, Yonghwan; Jang, Youngki; Choi, Joonhyung; Lee, Kyuseog

    2006-01-01

    In order to develop an advanced nuclear fuel, a series of pool side examination (PSE) is performed to confirm in-pile behavior of the fuel for commercial production. For this purpose, a vision system was developed to measure for mechanical integrity, such as assembly bowing, twist and growth, of the loaded lead test assembly. Using this vision system, three(3) times of PSE were carried out at Uljin Unit 3 and Kori Unit 2 for the advanced fuels, PLUS7 TM and 16ACE7 TM , developed by KNFC. Among the main characteristics of the vision system is very simple structure and measuring principal. This feature enables the equipment installation and inspection time to reduce largely, and leads the PSE can be finished without disturbance on the fuel loading and unloading activities during utility overhaul periods. And another feature is high accuracy and repeatability achieved by this vision system

  16. 77 FR 27847 - Qualification of Drivers; Exemption Applications; Vision

    Science.gov (United States)

    2012-05-11

    ... years shows no crashes and no convictions for moving violations in a CMV. Jolene A. Gauger Ms. Gauger... certify that in my medical opinion, Jolene Alison Gauger has sufficient vision to perform the driving...

  17. The Impact of Residual Vision in Spatial Skills of Individuals with Visual Impairments

    Science.gov (United States)

    Papadopoulos, Konstantinos; Koustriava, Eleni; Kartasidou, Lefkothea

    2011-01-01

    Loss of vision is believed to have a great impact on the acquisition of spatial knowledge. The aims of the present study are to examine the performance of individuals with visual impairments on spatial tasks and the impact of residual vision on processing these tasks. In all, 28 individuals with visual impairments--blindness or low…

  18. [Diagnostic performance of T-SPOT.TB on peripheral blood in combination with adenosine deaminase on pleural fluid for the diagnosis of tuberculous pleurisy within different age group].

    Science.gov (United States)

    Xu, H Y; Zhang, D Q; Ye, J R; Su, S S; Xie, Y P; Chen, C S; Li, Y P

    2017-06-27

    Objective: To evaluate the performance of T cell enzyme-linked immuno-spot assay (T-SPOT) on peripheral blood in combination with adenosine deaminase (ADA) on pleural fluid for diagnosis of tuberculous (TB) pleurisy within different age groups. Methods: The data of patients with pleural effusion from the Department of Pulmonary and Critical Care Medicine of the First Affiliated Hospital of Wenzhou Medical University from April 2012 to November 2016 were retrospectively analyzed, and the diagnoses of these patients were histopathologically confirmed through medical thoracoscopy. The cases who had confirmed diagnosis, in the same time, received peripheral blood T-SPOT.TB were enrolled. The performance of peripheral blood T-SPOT.TB in combination with pleural fluid ADA on diagnosing TB pleurisy in the younger patients (16-59 years old) and elderly patients (≥60 years old) were analyzed respectively. The sensitivity, specificity and the receiver operating characteristic (ROC) curve were adopted for statistical analysis. Results: A total of 448 cases were finally enrolled, 341(76.1%) confirmed with TB pleurisy, 224 males, 117 females, (47±19) years old; and 107 (23.9%) classified as non-TB pleurisy, 65 males, 42 females, (61±14) years old. There were 285 cases who were classified as younger group, and the other 163 cases were classified as elderly group. The sensitivity and specificity of peripheral blood T-SPOT.TB were 85.4% (204/239) and 71.7% (33/46) in the younger patients, 76.5% (78/102) and 59.0% (36/61) respectively in the elderly patients. The sensitivity of peripheral blood T-SPOT.TB in the younger patients was significantly higher than that in the elderly patients ( P =0.047). The sensitivity and specificity were 99.2% and 95.7% in combination with peripheral blood T-SPOT.TB and pleural fluid ADA respectively in the younger patients. The area under ROC curve (AUC) of T-SPOT.TB in the younger patients was 0.833, AUC of T-SPOT.TB combined with ADA was 0

  19. Virtual Vision

    Science.gov (United States)

    Terzopoulos, Demetri; Qureshi, Faisal Z.

    Computer vision and sensor networks researchers are increasingly motivated to investigate complex multi-camera sensing and control issues that arise in the automatic visual surveillance of extensive, highly populated public spaces such as airports and train stations. However, they often encounter serious impediments to deploying and experimenting with large-scale physical camera networks in such real-world environments. We propose an alternative approach called "Virtual Vision", which facilitates this type of research through the virtual reality simulation of populated urban spaces, camera sensor networks, and computer vision on commodity computers. We demonstrate the usefulness of our approach by developing two highly automated surveillance systems comprising passive and active pan/tilt/zoom cameras that are deployed in a virtual train station environment populated by autonomous, lifelike virtual pedestrians. The easily reconfigurable virtual cameras distributed in this environment generate synthetic video feeds that emulate those acquired by real surveillance cameras monitoring public spaces. The novel multi-camera control strategies that we describe enable the cameras to collaborate in persistently observing pedestrians of interest and in acquiring close-up videos of pedestrians in designated areas.

  20. Peripheral cold acclimatization in Antarctic scuba divers.

    Science.gov (United States)

    Bridgman, S A

    1991-08-01

    Peripheral acclimatization to cold in scuba divers stationed at the British Antarctic Survey's Signy Station was investigated during a year in Antarctica. Five divers and five non-diver controls underwent monthly laboratory tests of index finger immersion in cold water for 30 min. Index finger pulp temperature and time of onset of cold-induced vasodilatation (CIVD) were measured. Pain was recorded with verbal and numerical psychophysical subjective pain ratings. Average finger temperatures and median finger pain from 6-30 min of immersion, maximum finger temperatures during the first CIVD cycle, and finger temperatures at the onset of CIVD were calculated. Comparison of the variables recorded from divers and non-divers were performed with analysis of variance. No significant differences were found among the variables recorded from divers and non-divers. From a review of the literature, divers have responses typical of non-cold-adapted Caucasians. There is, therefore, no evidence that Signy divers peripherally acclimatized to cold. We suggest that these findings occur because either the whole body cooling which divers undergo inhibits peripheral acclimatization or because of insufficiently frequent or severe cold exposure while diving. Further basic studies on the duration, frequency and severity of cold exposure necessary to induce peripheral cold acclimatization are required before this question can be satisfactorily answered.

  1. Navigation integrity monitoring and obstacle detection for enhanced-vision systems

    Science.gov (United States)

    Korn, Bernd; Doehler, Hans-Ullrich; Hecker, Peter

    2001-08-01

    Typically, Enhanced Vision (EV) systems consist of two main parts, sensor vision and synthetic vision. Synthetic vision usually generates a virtual out-the-window view using databases and accurate navigation data, e. g. provided by differential GPS (DGPS). The reliability of the synthetic vision highly depends on both, the accuracy of the used database and the integrity of the navigation data. But especially in GPS based systems, the integrity of the navigation can't be guaranteed. Furthermore, only objects that are stored in the database can be displayed to the pilot. Consequently, unexpected obstacles are invisible and this might cause severe problems. Therefore, additional information has to be extracted from sensor data to overcome these problems. In particular, the sensor data analysis has to identify obstacles and has to monitor the integrity of databases and navigation. Furthermore, if a lack of integrity arises, navigation data, e.g. the relative position of runway and aircraft, has to be extracted directly from the sensor data. The main contribution of this paper is about the realization of these three sensor data analysis tasks within our EV system, which uses the HiVision 35 GHz MMW radar of EADS, Ulm as the primary EV sensor. For the integrity monitoring, objects extracted from radar images are registered with both database objects and objects (e. g. other aircrafts) transmitted via data link. This results in a classification into known and unknown radar image objects and consequently, in a validation of the integrity of database and navigation. Furthermore, special runway structures are searched for in the radar image where they should appear. The outcome of this runway check contributes to the integrity analysis, too. Concurrent to this investigation a radar image based navigation is performed without using neither precision navigation nor detailed database information to determine the aircraft's position relative to the runway. The performance of our

  2. The Relationship of Some Personality and Individual Characteristics with an Individual's Commitment to an Ideal Vision for Performance Improvement.

    Science.gov (United States)

    Watkins, Ryan

    2001-01-01

    Examined the relationship among specified personality and individual characteristics of university students with their level of commitment to a measurable, results-focused statement of an ideal vision. Discusses locus of control, generativity, self-efficacy, values, and risk taking in the use of an ideal vision for strategic planning, needs…

  3. Future Vision for Instrumentation, Information, and Control Modernization

    International Nuclear Information System (INIS)

    Thomas, Ken D.

    2012-01-01

    A Future Vision of a transformed nuclear plant operating model based on an integrated digital environment has been developed as part of the Advanced Instrumentation, Information, and Control (II and C) research pathway, under the Light Water Reactor (LWR) Sustainability Program. This is a research and development program sponsored by the U.S. Department of Energy (DOE), performed in close collaboration with the nuclear utility industry, to provide the technical foundations for licensing and managing the long-term, safe and economical operation of current nuclear power plants. II and C has been identified as a potential life-limiting issue for the domestic LWR fleet in addressing the reliability and aging concerns of the legacy systems in service today. The Future Vision is based on a digital architecture that encompasses all aspects of plant operations and support, integrating plant systems, plant work processes, and plant workers in a seamless digital environment to enhance nuclear safety, increase productivity, and improve overall plant performance. Pilot projects are being conducted as the means for industry to gain confidence in these new technologies for use in nuclear plant work activities. The pilot projects introduce new digital technologies into the nuclear plant operating environment at host operating plants to demonstrate and validate them for production usage. In turn, the pilot project technologies serve as the stepping stones to the eventual seamless digital environment as described in the Future Vision. Initial project results confirm that the technologies can provide substantial efficiency and human performance benefits while resolving the reliability and aging concerns of the legacy systems. (author)

  4. Stereo-vision and 3D reconstruction for nuclear mobile robots

    International Nuclear Information System (INIS)

    Lecoeur-Taibi, I.; Vacherand, F.; Rivallin, P.

    1991-01-01

    In order to perceive the geometric structure of the surrounding environment of a mobile robot, a 3D reconstruction system has been developed. Its main purpose is to provide geometric information to an operator who has to telepilot the vehicle in a nuclear power plant. The perception system is split into two parts: the vision part and the map building part. Vision is enhanced with a fusion process that rejects bas samples over space and time. The vision is based on trinocular stereo-vision which provides a range image of the image contours. It performs line contour correlation on horizontal image pairs and vertical image pairs. The results are then spatially fused in order to have one distance image, with a quality independent of the orientation of the contour. The 3D reconstruction is based on grid-based sensor fusion. As the robot moves and perceives its environment, distance data is accumulated onto a regular square grid, taking into account the uncertainty of the sensor through a sensor measurement statistical model. This approach allows both spatial and temporal fusion. Uncertainty due to sensor position and robot position is also integrated into the absolute local map. This system is modular and generic and can integrate 2D laser range finder and active vision. (author)

  5. 3D vision system for intelligent milking robot automation

    Science.gov (United States)

    Akhloufi, M. A.

    2013-12-01

    In a milking robot, the correct localization and positioning of milking teat cups is of very high importance. The milking robots technology has not changed since a decade and is based primarily on laser profiles for teats approximate positions estimation. This technology has reached its limit and does not allow optimal positioning of the milking cups. Also, in the presence of occlusions, the milking robot fails to milk the cow. These problems, have economic consequences for producers and animal health (e.g. development of mastitis). To overcome the limitations of current robots, we have developed a new system based on 3D vision, capable of efficiently positioning the milking cups. A prototype of an intelligent robot system based on 3D vision for real-time positioning of a milking robot has been built and tested under various conditions on a synthetic udder model (in static and moving scenarios). Experimental tests, were performed using 3D Time-Of-Flight (TOF) and RGBD cameras. The proposed algorithms permit the online segmentation of teats by combing 2D and 3D visual information. The obtained results permit the teat 3D position computation. This information is then sent to the milking robot for teat cups positioning. The vision system has a real-time performance and monitors the optimal positioning of the cups even in the presence of motion. The obtained results, with both TOF and RGBD cameras, show the good performance of the proposed system. The best performance was obtained with RGBD cameras. This latter technology will be used in future real life experimental tests.

  6. UNDERSTANDING AND PREVENTING COMPUTER VISION SYNDROME

    OpenAIRE

    REDDY SC; LOH KY

    2008-01-01

    The invention of computer and advancement in information technology has revolutionized and benefited the society but at the same time has caused symptoms related to its usage such as ocular sprain, irritation, redness, dryness, blurred vision and double vision. This cluster of symptoms is known as computer vision syndrome which is characterized by the visual symptoms which result from interaction with computer display or its environment. Three major mechanisms that lead to computer vision syn...

  7. A stereo vision-based obstacle detection system in vehicles

    Science.gov (United States)

    Huh, Kunsoo; Park, Jaehak; Hwang, Junyeon; Hong, Daegun

    2008-02-01

    Obstacle detection is a crucial issue for driver assistance systems as well as for autonomous vehicle guidance function and it has to be performed with high reliability to avoid any potential collision with the front vehicle. The vision-based obstacle detection systems are regarded promising for this purpose because they require little infrastructure on a highway. However, the feasibility of these systems in passenger car requires accurate and robust sensing performance. In this paper, an obstacle detection system using stereo vision sensors is developed. This system utilizes feature matching, epipoplar constraint and feature aggregation in order to robustly detect the initial corresponding pairs. After the initial detection, the system executes the tracking algorithm for the obstacles. The proposed system can detect a front obstacle, a leading vehicle and a vehicle cutting into the lane. Then, the position parameters of the obstacles and leading vehicles can be obtained. The proposed obstacle detection system is implemented on a passenger car and its performance is verified experimentally.

  8. Color Vision in Aniridia.

    Science.gov (United States)

    Pedersen, Hilde R; Hagen, Lene A; Landsend, Erlend C S; Gilson, Stuart J; Utheim, Øygunn A; Utheim, Tor P; Neitz, Maureen; Baraas, Rigmor C

    2018-04-01

    To assess color vision and its association with retinal structure in persons with congenital aniridia. We included 36 persons with congenital aniridia (10-66 years), and 52 healthy, normal trichromatic controls (10-74 years) in the study. Color vision was assessed with Hardy-Rand-Rittler (HRR) pseudo-isochromatic plates (4th ed., 2002); Cambridge Color Test and a low-vision version of the Color Assessment and Diagnosis test (CAD-LV). Cone-opsin genes were analyzed to confirm normal versus congenital color vision deficiencies. Visual acuity and ocular media opacities were assessed. The central 30° of both eyes were imaged with the Heidelberg Spectralis OCT2 to grade the severity of foveal hypoplasia (FH, normal to complete: 0-4). Five participants with aniridia had cone opsin genes conferring deutan color vision deficiency and were excluded from further analysis. Of the 31 with aniridia and normal opsin genes, 11 made two or more red-green (RG) errors on HRR, four of whom also made yellow-blue (YB) errors; one made YB errors only. A total of 19 participants had higher CAD-LV RG thresholds, of which eight also had higher CAD-LV YB thresholds, than normal controls. In aniridia, the thresholds were higher along the RG than the YB axis, and those with a complete FH had significantly higher RG thresholds than those with mild FH (P = 0.038). Additional increase in YB threshold was associated with secondary ocular pathology. Arrested foveal formation and associated alterations in retinal processing are likely to be the primary reason for impaired red-green color vision in aniridia.

  9. Lambda Vision

    Science.gov (United States)

    Czajkowski, Michael

    2014-06-01

    There is an explosion in the quantity and quality of IMINT data being captured in Intelligence Surveillance and Reconnaissance (ISR) today. While automated exploitation techniques involving computer vision are arriving, only a few architectures can manage both the storage and bandwidth of large volumes of IMINT data and also present results to analysts quickly. Lockheed Martin Advanced Technology Laboratories (ATL) has been actively researching in the area of applying Big Data cloud computing techniques to computer vision applications. This paper presents the results of this work in adopting a Lambda Architecture to process and disseminate IMINT data using computer vision algorithms. The approach embodies an end-to-end solution by processing IMINT data from sensors to serving information products quickly to analysts, independent of the size of the data. The solution lies in dividing up the architecture into a speed layer for low-latent processing and a batch layer for higher quality answers at the expense of time, but in a robust and fault-tolerant way. This approach was evaluated using a large corpus of IMINT data collected by a C-130 Shadow Harvest sensor over Afghanistan from 2010 through 2012. The evaluation data corpus included full motion video from both narrow and wide area field-of-views. The evaluation was done on a scaled-out cloud infrastructure that is similar in composition to those found in the Intelligence Community. The paper shows experimental results to prove the scalability of the architecture and precision of its results using a computer vision algorithm designed to identify man-made objects in sparse data terrain.

  10. Smartphones as image processing systems for prosthetic vision.

    Science.gov (United States)

    Zapf, Marc P; Matteucci, Paul B; Lovell, Nigel H; Suaning, Gregg J

    2013-01-01

    The feasibility of implants for prosthetic vision has been demonstrated by research and commercial organizations. In most devices, an essential forerunner to the internal stimulation circuit is an external electronics solution for capturing, processing and relaying image information as well as extracting useful features from the scene surrounding the patient. The capabilities and multitude of image processing algorithms that can be performed by the device in real-time plays a major part in the final quality of the prosthetic vision. It is therefore optimal to use powerful hardware yet to avoid bulky, straining solutions. Recent publications have reported of portable single-board computers fast enough for computationally intensive image processing. Following the rapid evolution of commercial, ultra-portable ARM (Advanced RISC machine) mobile devices, the authors investigated the feasibility of modern smartphones running complex face detection as external processing devices for vision implants. The role of dedicated graphics processors in speeding up computation was evaluated while performing a demanding noise reduction algorithm (image denoising). The time required for face detection was found to decrease by 95% from 2.5 year old to recent devices. In denoising, graphics acceleration played a major role, speeding up denoising by a factor of 18. These results demonstrate that the technology has matured sufficiently to be considered as a valid external electronics platform for visual prosthetic research.

  11. Jane Addams’ Social Vision

    DEFF Research Database (Denmark)

    Villadsen, Kaspar

    2018-01-01

    resonated with key tenets of social gospel theology, which imbued her texts with an overarching vision of humanity’s progressive history. It is suggested that Addams’ vision of a major transition in industrial society, one involving a BChristian renaissance^ and individuals’ transformation into Bsocialized...

  12. Computer vision for sports

    DEFF Research Database (Denmark)

    Thomas, Graham; Gade, Rikke; Moeslund, Thomas B.

    2017-01-01

    fixed to players or equipment is generally not possible. This provides a rich set of opportunities for the application of computer vision techniques to help the competitors, coaches and audience. This paper discusses a selection of current commercial applications that use computer vision for sports...

  13. Toward The Robot Eye: Isomorphic Representation For Machine Vision

    Science.gov (United States)

    Schenker, Paul S.

    1981-10-01

    This paper surveys some issues confronting the conception of models for general purpose vision systems. We draw parallels to requirements of human performance under visual transformations naturally occurring in the ecological environment. We argue that successful real world vision systems require a strong component of analogical reasoning. We propose a course of investigation into appropriate models, and illustrate some of these proposals by a simple example. Our study emphasizes the potential importance of isomorphic representations - models of image and scene which embed a metric of their respective spaces, and whose topological structure facilitates identification of scene descriptors that are invariant under viewing transformations.

  14. Propylthiouracil and peripheral neuropathy

    Directory of Open Access Journals (Sweden)

    Valentina Van Boekel

    1992-06-01

    Full Text Available Peripheral neuropathy is a rare manifestation in hyperthyroidism. We describe the neurological manifestations of a 38 year old female with Graves' disease who developed peripheral neuropathy in the course of her treatment with propylthiouracil. After the drug was tapered off, the neurological signs disappeared. Therefore, we call attention for a possible toxic effect on peripheral nervous system caused by this drug.

  15. Sonographic identification of peripheral nerves in the forearm

    Directory of Open Access Journals (Sweden)

    Saundra A Jackson

    2016-01-01

    Full Text Available Background: With the growing utilization of ultrasonography in emergency medicine combined with the concern over adequate pain management in the emergency department (ED, ultrasound guidance for peripheral nerve blockade in ED is an area of increasing interest. The medical literature has multiple reports supporting the use of ultrasound guidance in peripheral nerve blocks. However, to perform a peripheral nerve block, one must first be able to reliably identify the specific nerve before the procedure. Objective: The primary purpose of this study is to describe the number of supervised peripheral nerve examinations that are necessary for an emergency medicine physician to gain proficiency in accurately locating and identifying the median, radial, and ulnar nerves of the forearm via ultrasound. Methods: The proficiency outcome was defined as the number of attempts before a resident is able to correctly locate and identify the nerves on ten consecutive examinations. Didactic education was provided via a 1 h lecture on forearm anatomy, sonographic technique, and identification of the nerves. Participants also received two supervised hands-on examinations for each nerve. Count data are summarized using percentages or medians and range. Random effects negative binomial regression was used for modeling panel count data. Results: Complete data for the number of attempts, gender, and postgraduate year (PGY training year were available for 38 residents. Nineteen males and 19 females performed examinations. The median PGY year in practice was 3 (range 1-3, with 10 (27% in year 1, 8 (22% in year 2, and 19 (51% in year 3 or beyond. The median number (range of required supervised attempts for radial, median, and ulnar nerves was 1 (0-12, 0 (0-10, and 0 (0-17, respectively. Conclusion: We can conclude that the maximum number of supervised attempts to achieve accurate nerve identification was 17 (ulnar, 12 (radial, and 10 (median in our study. The only

  16. The effect of normal aging and age-related macular degeneration on perceptual learning.

    Science.gov (United States)

    Astle, Andrew T; Blighe, Alan J; Webb, Ben S; McGraw, Paul V

    2015-01-01

    We investigated whether perceptual learning could be used to improve peripheral word identification speed. The relationship between the magnitude of learning and age was established in normal participants to determine whether perceptual learning effects are age invariant. We then investigated whether training could lead to improvements in patients with age-related macular degeneration (AMD). Twenty-eight participants with normal vision and five participants with AMD trained on a word identification task. They were required to identify three-letter words, presented 10° from fixation. To standardize crowding across each of the letters that made up the word, words were flanked laterally by randomly chosen letters. Word identification performance was measured psychophysically using a staircase procedure. Significant improvements in peripheral word identification speed were demonstrated following training (71% ± 18%). Initial task performance was correlated with age, with older participants having poorer performance. However, older adults learned more rapidly such that, following training, they reached the same level of performance as their younger counterparts. As a function of number of trials completed, patients with AMD learned at an equivalent rate as age-matched participants with normal vision. Improvements in word identification speed were maintained at least 6 months after training. We have demonstrated that temporal aspects of word recognition can be improved in peripheral vision with training across a range of ages and these learned improvements are relatively enduring. However, training targeted at other bottlenecks to peripheral reading ability, such as visual crowding, may need to be incorporated to optimize this approach.

  17. Peripheral Neuropathy: Symptoms and Signs

    Science.gov (United States)

    ... Utah Research News Make a Difference Symptoms of Peripheral Neuropathy Print This Page Peripheral Neuropathy symptoms usually start ... more slowly over many years. The symptoms of peripheral neuropathy often include: A sensation of wearing an invisible “ ...

  18. Miniaturisation of Pressure-Sensitive Paint Measurement Systems Using Low-Cost, Miniaturised Machine Vision Cameras.

    Science.gov (United States)

    Quinn, Mark Kenneth; Spinosa, Emanuele; Roberts, David A

    2017-07-25

    Measurements of pressure-sensitive paint (PSP) have been performed using new or non-scientific imaging technology based on machine vision tools. Machine vision camera systems are typically used for automated inspection or process monitoring. Such devices offer the benefits of lower cost and reduced size compared with typically scientific-grade cameras; however, their optical qualities and suitability have yet to be determined. This research intends to show relevant imaging characteristics and also show the applicability of such imaging technology for PSP. Details of camera performance are benchmarked and compared to standard scientific imaging equipment and subsequent PSP tests are conducted using a static calibration chamber. The findings demonstrate that machine vision technology can be used for PSP measurements, opening up the possibility of performing measurements on-board small-scale model such as those used for wind tunnel testing or measurements in confined spaces with limited optical access.

  19. Miniaturisation of Pressure-Sensitive Paint Measurement Systems Using Low-Cost, Miniaturised Machine Vision Cameras

    Directory of Open Access Journals (Sweden)

    Mark Kenneth Quinn

    2017-07-01

    Full Text Available Measurements of pressure-sensitive paint (PSP have been performed using new or non-scientific imaging technology based on machine vision tools. Machine vision camera systems are typically used for automated inspection or process monitoring. Such devices offer the benefits of lower cost and reduced size compared with typically scientific-grade cameras; however, their optical qualities and suitability have yet to be determined. This research intends to show relevant imaging characteristics and also show the applicability of such imaging technology for PSP. Details of camera performance are benchmarked and compared to standard scientific imaging equipment and subsequent PSP tests are conducted using a static calibration chamber. The findings demonstrate that machine vision technology can be used for PSP measurements, opening up the possibility of performing measurements on-board small-scale model such as those used for wind tunnel testing or measurements in confined spaces with limited optical access.

  20. Vision-based obstacle recognition system for automated lawn mower robot development

    Science.gov (United States)

    Mohd Zin, Zalhan; Ibrahim, Ratnawati

    2011-06-01

    Digital image processing techniques (DIP) have been widely used in various types of application recently. Classification and recognition of a specific object using vision system require some challenging tasks in the field of image processing and artificial intelligence. The ability and efficiency of vision system to capture and process the images is very important for any intelligent system such as autonomous robot. This paper gives attention to the development of a vision system that could contribute to the development of an automated vision based lawn mower robot. The works involve on the implementation of DIP techniques to detect and recognize three different types of obstacles that usually exist on a football field. The focus was given on the study on different types and sizes of obstacles, the development of vision based obstacle recognition system and the evaluation of the system's performance. Image processing techniques such as image filtering, segmentation, enhancement and edge detection have been applied in the system. The results have shown that the developed system is able to detect and recognize various types of obstacles on a football field with recognition rate of more 80%.

  1. Validity of the Worth 4 Dot Test in Patients with Red-Green Color Vision Defect.

    Science.gov (United States)

    Bak, Eunoo; Yang, Hee Kyung; Hwang, Jeong-Min

    2017-05-01

    The Worth four dot test uses red and green glasses for binocular dissociation, and although it has been believed that patients with red-green color vision defects cannot accurately perform the Worth four dot test, this has not been validated. Therefore, the purpose of this study was to demonstrate the validity of the Worth four dot test in patients with congenital red-green color vision defects who have normal or abnormal binocular vision. A retrospective review of medical records was performed on 30 consecutive congenital red-green color vision defect patients who underwent the Worth four dot test. The type of color vision anomaly was determined by the Hardy Rand and Rittler (HRR) pseudoisochromatic plate test, Ishihara color test, anomaloscope, and/or the 100 hue test. All patients underwent a complete ophthalmologic examination. Binocular sensory status was evaluated with the Worth four dot test and Randot stereotest. The results were interpreted according to the presence of strabismus or amblyopia. Among the 30 patients, 24 had normal visual acuity without strabismus nor amblyopia and 6 patients had strabismus and/or amblyopia. The 24 patients without strabismus nor amblyopia all showed binocular fusional responses by seeing four dots of the Worth four dot test. Meanwhile, the six patients with strabismus or amblyopia showed various results of fusion, suppression, and diplopia. Congenital red-green color vision defect patients of different types and variable degree of binocularity could successfully perform the Worth four dot test. They showed reliable results that were in accordance with their estimated binocular sensory status.

  2. Computer Vision for Timber Harvesting

    DEFF Research Database (Denmark)

    Dahl, Anders Lindbjerg

    The goal of this thesis is to investigate computer vision methods for timber harvesting operations. The background for developing computer vision for timber harvesting is to document origin of timber and to collect qualitative and quantitative parameters concerning the timber for efficient harvest...... segments. The purpose of image segmentation is to make the basis for more advanced computer vision methods like object recognition and classification. Our second method concerns image classification and we present a method where we classify small timber samples to tree species based on Active Appearance...... to the development of the logTracker system the described methods have a general applicability making them useful for many other computer vision problems....

  3. Is clinical performance adversely affected by wearing gloves during paediatric peripheral intravenous cannulation?

    Science.gov (United States)

    Zhang, Michael; Lee, Mark; Knott, Susan

    2014-10-01

    To investigate if wearing protective gloves during paediatric intravenous cannulation affects performance of the procedure. This was a prospective observational study. Peripheral intravenous cannulation (PIVC) performed within the Paediatric ED was observed and recorded over a 12 month period. Data were compared between those clinicians wearing gloves and those not wearing gloves during PIVC. One thousand and twenty paediatric cannulations were recorded during the observed period. The mean age of the children was 5.79 years. The overall success rate of cannulation was 86.18% and first attempt success rate 76.08%. Overall, gloves were used by 54.31% of clinicians to establish vascular access; glove use was lowest in the registrar group (41.11% compliance rate). The glove-wearing group had comparable overall success rate of 85.74% (475/554) to the no-gloves group of 86.70% (404/466). The difference was not statistically significant (P > 0.05). Higher incidence of significant blood spillage during the procedure was observed among clinicians wearing no gloves (16.74%) in comparison with their glove-wearing counterparts (9.03%, P glove-wearing group and no-gloves group (3.94% vs 3.76%, P > 0.05). The present study shows that the use of protective gloves was not associated with adverse outcomes of clinical performance during paediatric cannulation. The low compliance rate of gloves use is alarming, and many clinicians might be exposed to potential blood-borne infections. Clinicians should be encouraged and supported to use gloves for paediatric cannulation. © 2014 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  4. Vehicle Detection with Occlusion Handling, Tracking, and OC-SVM Classification: A High Performance Vision-Based System

    Science.gov (United States)

    Velazquez-Pupo, Roxana; Sierra-Romero, Alberto; Torres-Roman, Deni; Shkvarko, Yuriy V.; Romero-Delgado, Misael

    2018-01-01

    This paper presents a high performance vision-based system with a single static camera for traffic surveillance, for moving vehicle detection with occlusion handling, tracking, counting, and One Class Support Vector Machine (OC-SVM) classification. In this approach, moving objects are first segmented from the background using the adaptive Gaussian Mixture Model (GMM). After that, several geometric features are extracted, such as vehicle area, height, width, centroid, and bounding box. As occlusion is present, an algorithm was implemented to reduce it. The tracking is performed with adaptive Kalman filter. Finally, the selected geometric features: estimated area, height, and width are used by different classifiers in order to sort vehicles into three classes: small, midsize, and large. Extensive experimental results in eight real traffic videos with more than 4000 ground truth vehicles have shown that the improved system can run in real time under an occlusion index of 0.312 and classify vehicles with a global detection rate or recall, precision, and F-measure of up to 98.190%, and an F-measure of up to 99.051% for midsize vehicles. PMID:29382078

  5. Registry Assessment of Peripheral Interventional Devices (RAPID) - Registry Assessment of Peripheral Interventional Devices Core Data Elements.

    Science.gov (United States)

    Jones, W Schuyler; Krucoff, Mitchell W; Morales, Pablo; Wilgus, Rebecca W; Heath, Anne H; Williams, Mary F; Tcheng, James E; Marinac-Dabic, J Danica; Malone, Misti L; Reed, Terrie L; Fukaya, Rie; Lookstein, Robert; Handa, Nobuhiro; Aronow, Herbert D; Bertges, Daniel J; Jaff, Michael R; Tsai, Thomas T; Smale, Joshua A; Zaugg, Margo J; Thatcher, Robert J; Cronenwett, Jack L; Nc, Durham; Md, Silver Spring; Japan, Tokyo; Ny, New York; Ri, Providence; Vt, Burlington; Mass, Newton; Colo, Denver; Ariz, Tempe; Calif, Santa Clara; Minn, Minneapolis; Nh, Lebanon

    2018-01-25

    The current state of evaluating patients with peripheral artery disease and more specifically of evaluating medical devices used for peripheral vascular intervention (PVI) remains challenging because of the heterogeneity of the disease process, the multiple physician specialties that perform PVI, the multitude of devices available to treat peripheral artery disease, and the lack of consensus about the best treatment approaches. Because PVI core data elements are not standardized across clinical care, clinical trials, and registries, aggregation of data across different data sources and physician specialties is currently not feasible.Methods and Results:Under the auspices of the U.S. Food and Drug Administration's Medical Device Epidemiology Network initiative-and its PASSION (Predictable and Sustainable Implementation of the National Registries) program, in conjunction with other efforts to align clinical data standards-the Registry Assessment of Peripheral Interventional Devices (RAPID) workgroup was convened. RAPID is a collaborative, multidisciplinary effort to develop a consensus lexicon and to promote interoperability across clinical care, clinical trials, and national and international registries of PVI. The current manuscript presents the initial work from RAPID to standardize clinical data elements and definitions, to establish a framework within electronic health records and health information technology procedural reporting systems, and to implement an informatics-based approach to promote the conduct of pragmatic clinical trials and registry efforts in PVI. Ultimately, we hope this work will facilitate and improve device evaluation and surveillance for patients, clinicians, health outcomes researchers, industry, policymakers, and regulators.

  6. Pharmacokinetics of 2-nitroimidazole hypoxic cell radiosensitizers in rodent peripheral nervous tissue

    International Nuclear Information System (INIS)

    Sasai, K.; Shibamoto, Y.; Abe, M.; Takahashi, M.; Ito, T.; Nishimoto, S.

    1990-01-01

    The concentrations of seven 2-nitroimidazoles - including misonidazole, etanidazole (SR-2508), pimonidazole (Ro 03-8799), desmethylmisonidazole (Ro 05-9963), RK28, RP170 and KU2285 - were measured in the sciatic nerves of C3H/He mice using reverse-phase high-performance liquid chromatography. The apparent biological half-lives of the compounds in the peripheral nerves were correlated to their hydrophilicity: the more hydrophilic the compound, the longer the apparent biological half-life in the peripheral nervous tissue of the mice. Measurement of drug exposure in the rodent peripheral nervous system, rather than in the brain, was a better indicator for estimating the occurrence of clinical peripheral neuropathy by 2-nitroimidazoles. (author)

  7. Pharmacokinetics of 2-nitroimidazole hypoxic cell radiosensitizers in rodent peripheral nervous tissue

    Energy Technology Data Exchange (ETDEWEB)

    Sasai, K.; Shibamoto, Y.; Abe, M. (Kyoto Univ. (Japan). Faculty of Medicine); Takahashi, M. (Kyoto Univ. (Japan). Chest Disease Research Inst.); Ito, T.; Nishimoto, S. (Kyoto Univ. (Japan). Faculty of Engineering)

    1990-05-01

    The concentrations of seven 2-nitroimidazoles - including misonidazole, etanidazole (SR-2508), pimonidazole (Ro 03-8799), desmethylmisonidazole (Ro 05-9963), RK28, RP170 and KU2285 - were measured in the sciatic nerves of C3H/He mice using reverse-phase high-performance liquid chromatography. The apparent biological half-lives of the compounds in the peripheral nerves were correlated to their hydrophilicity: the more hydrophilic the compound, the longer the apparent biological half-life in the peripheral nervous tissue of the mice. Measurement of drug exposure in the rodent peripheral nervous system, rather than in the brain, was a better indicator for estimating the occurrence of clinical peripheral neuropathy by 2-nitroimidazoles. (author).

  8. Night Vision Manual for the Flight Surgeon.

    Science.gov (United States)

    1985-08-01

    macula and fovea centralis. 4. Duality theory of vision-extends sensitivity of vision over 100,000 times (Fig. 12). ~Im Uilting Ullmlrage WVIVIWCentral...lowered night vision capa- bilities due to disease or degenerations . F. Hypoxia 1. Decrement of central vision due to 02 lack is quite small; such as, at

  9. Registry Assessment of Peripheral Interventional Devices (RAPID): Registry assessment of peripheral interventional devices core data elements.

    Science.gov (United States)

    Jones, W Schuyler; Krucoff, Mitchell W; Morales, Pablo; Wilgus, Rebecca W; Heath, Anne H; Williams, Mary F; Tcheng, James E; Marinac-Dabic, J Danica; Malone, Misti L; Reed, Terrie L; Fukaya, Rie; Lookstein, Robert A; Handa, Nobuhiro; Aronow, Herbert D; Bertges, Daniel J; Jaff, Michael R; Tsai, Thomas T; Smale, Joshua A; Zaugg, Margo J; Thatcher, Robert J; Cronenwett, Jack L

    2018-02-01

    The current state of evaluating patients with peripheral artery disease and more specifically of evaluating medical devices used for peripheral vascular intervention (PVI) remains challenging because of the heterogeneity of the disease process, the multiple physician specialties that perform PVI, the multitude of devices available to treat peripheral artery disease, and the lack of consensus about the best treatment approaches. Because PVI core data elements are not standardized across clinical care, clinical trials, and registries, aggregation of data across different data sources and physician specialties is currently not feasible. Under the auspices of the U.S. Food and Drug Administration's Medical Device Epidemiology Network initiative-and its PASSION (Predictable and Sustainable Implementation of the National Registries) program, in conjunction with other efforts to align clinical data standards-the Registry Assessment of Peripheral Interventional Devices (RAPID) workgroup was convened. RAPID is a collaborative, multidisciplinary effort to develop a consensus lexicon and to promote interoperability across clinical care, clinical trials, and national and international registries of PVI. The current manuscript presents the initial work from RAPID to standardize clinical data elements and definitions, to establish a framework within electronic health records and health information technology procedural reporting systems, and to implement an informatics-based approach to promote the conduct of pragmatic clinical trials and registry efforts in PVI. Ultimately, we hope this work will facilitate and improve device evaluation and surveillance for patients, clinicians, health outcomes researchers, industry, policymakers, and regulators. Copyright © 2017 Society for Vascular Surgery. All rights reserved.

  10. Effects of Dioscoreae Rhizoma (SanYak on Peripheral Neuropathy and its Safety

    Directory of Open Access Journals (Sweden)

    Kim Min-jung

    2013-09-01

    Full Text Available Objectives: This study aimed to evaluate the evidence available in the literature for the safety and efficacy of Dioscoreae Rhizoma (DR for the treatment of peripheral neuropathy. Methods: Literature searches were performed in MEDLINE and three Korean medical databases up to April 2013. All studies evaluating the effects on peripheral neuropathy or the safety of DR monopreparations were considered. Results: Three studies - DR extract per os (po on diabetic neuropathy in mice, DR extract injection on the peripheral sciatic nerve after crush injury in rats and DR extract injection to patients with peripheral facial paralysis proved that DR treatments were effective for the treatment of nerve injuries. Conclusions: In conclusion, we found the DR has a strong positive potential for the treatment of peripheral neuropathy, but studies addressing direct factors related to the nerve still remain insufficient.

  11. Gait disorder rehabilitation using vision and non-vision based sensors: A systematic review

    Directory of Open Access Journals (Sweden)

    Asraf Ali

    2012-08-01

    Full Text Available Even though the amount of rehabilitation guidelines has never been greater, uncertainty continues to arise regarding the efficiency and effectiveness of the rehabilitation of gait disorders. This question has been hindered by the lack of information on accurate measurements of gait disorders. Thus, this article reviews the rehabilitation systems for gait disorder using vision and non-vision sensor technologies, as well as the combination of these. All papers published in the English language between 1990 and June, 2012 that had the phrases “gait disorder” “rehabilitation”, “vision sensor”, or “non vision sensor” in the title, abstract, or keywords were identified from the SpringerLink, ELSEVIER, PubMed, and IEEE databases. Some synonyms of these phrases and the logical words “and” “or” and “not” were also used in the article searching procedure. Out of the 91 published articles found, this review identified 84 articles that described the rehabilitation of gait disorders using different types of sensor technologies. This literature set presented strong evidence for the development of rehabilitation systems using a markerless vision-based sensor technology. We therefore believe that the information contained in this review paper will assist the progress of the development of rehabilitation systems for human gait disorders.

  12. Trichloropropane and dichlorohydrin associated with painful peripheral neurotoxicity.

    Science.gov (United States)

    Shi, Xiaobing; Yu, Shengyuan

    2013-10-01

    Trichloropropane (TCP) and dichlorohydrin are widely used in industrial production; however, TCP and dichlorohydrin poisoning are rarely encountered in clinical practice. There have been no cases of peripheral neurotoxicity previously reported. A cluster of 23 patients who had been exposed to high levels of TCP and dichlorohydrin presented with painful peripheral neuropathy, and the pain was assessed using a visual analogue scale (VAS). Nerve conduction studies (NCS) were performed in all patients. All patients demonstrated symmetrical pin-prick pain in a stocking distribution in the lower limbs, with VAS scores between 3 and 10, with an average score of 6.8. NCS showed a mild mixture of axonal and demyelinating sensorimotor polyneuropathy in 14 of the 23 patients. After administration of standard neuropathic pain medication, pain was relieved in most patients. Painful peripheral neuropathy was the primary symptom observed in our patients, which differs from clinical and animal model reports of TCP or dichlorohydrin poisoning. However, the pathogenesis remains unidentified. TCP may be added to the list of industrial products that are toxic to the peripheral sensory nerves. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Donating Peripheral Blood Stem Cells

    Science.gov (United States)

    ... Print this page My Cart Donating peripheral blood stem cells Peripheral blood stem cell (PBSC) donation is a nonsurgical procedure to collect ... Donating bone marrow Donor experiences videos Peripheral blood stem cell (PBSC) donation is one of two methods of ...

  14. The Trickle-Down Effect of Institutional Vision: Vision Statements and Academic Advising

    Science.gov (United States)

    Abelman, Robert; Atkin, David; Dalessandro, Amy; Snyder-Suhy, Sharon; Janstova, Patricie

    2007-01-01

    A description of the kinds of educated humans to be cultivated at a particular institution can be found in the college or university vision statement. The extent that vision is reflected in the governing models of advising operations, known by personnel, and transformed into day-to-day activities was assessed through a NACADA membership survey.…

  15. Composition of a Vision Screen for Servicemembers With Traumatic Brain Injury: Consensus Using a Modified Nominal Group Technique

    Science.gov (United States)

    Finkelstein, Marsha; Llanos, Imelda; Scheiman, Mitchell; Wagener, Sharon Gowdy

    2014-01-01

    Vision impairment is common in the first year after traumatic brain injury (TBI), including among service members whose brain injuries occurred during deployment in Iraq and Afghanistan. Occupational therapy practitioners provide routine vision screening to inform treatment planning and referral to vision specialists, but existing methods are lacking because many tests were developed for children and do not screen for vision dysfunction typical of TBI. An expert panel was charged with specifying the composition of a vision screening protocol for servicemembers with TBI. A modified nominal group technique fostered discussion and objective determinations of consensus. After considering 29 vision tests, the panel recommended a nine-test vision screening that examines functional performance, self-reported problems, far–near acuity, reading, accommodation, convergence, eye alignment and binocular vision, saccades, pursuits, and visual fields. Research is needed to develop reliable, valid, and clinically feasible vision screening protocols to identify TBI-related vision disorders in adults. PMID:25005505

  16. Correlation Between Near-Vision Acuity and the Incidence of Peritoneal Dialysis-Related Infections.

    Science.gov (United States)

    Kojima, Shigeki; Sakurada, Tsutomu; Koitabashi, Kenichiro; Kojima, Kaori; Watanabe, Shiika; Uchida, Daisuke; Kaneshiro, Nagayuki; Konno, Yusuke; Shibagaki, Yugo

    Peritoneal dialysis (PD)-related infections (PDIs) such as peritonitis, exit-site infection, and tunnel infection are serious complications affecting patients on PD. Because patients with diabetes (DM) and of older age have increased in number in Japan, the number of patients with visual impairment is estimated also to have increased. Near vision is necessary for performing proper PD daily care. However, no studies have reported whether visual impairment is likely to increase the risk of PDIs.Our study included 31 PD patients (16 men, 15 women; mean age: 61.5 ± 11.8 years; mean PD duration: 27.3 ± 20.3 months; 38.7% with DM; 54.8% wearing glasses) who performed their own PD care. At our facility and related facilities, we used a standard near-vision test chart, which classifies vision into 12 grades, from 0.1 (poor) to 1.5 (clear), to assess near-vision binocular visual acuity in those patients between March 2015 and September 2015. In addition, we retrospectively examined the medical records of the patients to determine their history of PDIs. We then evaluated the correlation between near-vision acuity and the incidence of PDIs.Mean measured near-vision acuity was 0.61 ± 0.29, and we observed no significant difference in the visual acuity of patients with and without DM (0.55 ± 0.31 vs. 0.63 ± 0.26 respectively, p = 0.477). In addition, we observed no significant difference in the incidence of PDIs between patients with and without DM (1.298 ± 1.609 per year vs. 1.164 ± 0.908 per year respectively, p = 0.804). We did not find a correlation between near-vision acuity and the incidence of PDIs (r = -0.071, p = 0.795).

  17. The role of visual perception measures used in sports vision programmes in predicting actual game performance in Division I collegiate hockey players.

    Science.gov (United States)

    Poltavski, Dmitri; Biberdorf, David

    2015-01-01

    Abstract In the growing field of sports vision little is still known about unique attributes of visual processing in ice hockey and what role visual processing plays in the overall athlete's performance. In the present study we evaluated whether visual, perceptual and cognitive/motor variables collected using the Nike SPARQ Sensory Training Station have significant relevance to the real game statistics of 38 Division I collegiate male and female hockey players. The results demonstrated that 69% of variance in the goals made by forwards in 2011-2013 could be predicted by their faster reaction time to a visual stimulus, better visual memory, better visual discrimination and a faster ability to shift focus between near and far objects. Approximately 33% of variance in game points was significantly related to better discrimination among competing visual stimuli. In addition, reaction time to a visual stimulus as well as stereoptic quickness significantly accounted for 24% of variance in the mean duration of the player's penalty time. This is one of the first studies to show that some of the visual skills that state-of-the-art generalised sports vision programmes are purported to target may indeed be important for hockey players' actual performance on the ice.

  18. Lessons Learned from the Creation of a Center of Excellence in Low Vision and Vision Rehabilitation in Wenzhou, China

    Science.gov (United States)

    Marinoff, Rebecca; Heilberger, Michael H.

    2017-01-01

    A model Center of Excellence in Low Vision and Vision Rehabilitation was created in a health care setting in China utilizing an inter-institutional relationship with a United States optometric institution. Accomplishments of, limitations to, and stimuli to the provision of low vision and vision rehabilitation services are shared.

  19. A Hybrid Architecture for Vision-Based Obstacle Avoidance

    Directory of Open Access Journals (Sweden)

    Mehmet Serdar Güzel

    2013-01-01

    Full Text Available This paper proposes a new obstacle avoidance method using a single monocular vision camera as the only sensor which is called as Hybrid Architecture. This architecture integrates a high performance appearance-based obstacle detection method into an optical flow-based navigation system. The hybrid architecture was designed and implemented to run both methods simultaneously and is able to combine the results of each method using a novel arbitration mechanism. The proposed strategy successfully fused two different vision-based obstacle avoidance methods using this arbitration mechanism in order to permit a safer obstacle avoidance system. Accordingly, to establish the adequacy of the design of the obstacle avoidance system, a series of experiments were conducted. The results demonstrate the characteristics of the proposed architecture, and the results prove that its performance is somewhat better than the conventional optical flow-based architecture. Especially, the robot employing Hybrid Architecture avoids lateral obstacles in a more smooth and robust manner than when using the conventional optical flow-based technique.

  20. Extending Driving Vision Based on Image Mosaic Technique

    Directory of Open Access Journals (Sweden)

    Chen Deng

    2017-01-01

    Full Text Available Car cameras have been used extensively to assist driving by make driving visible. However, due to the limitation of the Angle of View (AoV, the dead zone still exists, which is a primary origin of car accidents. In this paper, we introduce a system to extend the vision of drivers to 360 degrees. Our system consists of four wide-angle cameras, which are mounted at different sides of a car. Although the AoV of each camera is within 180 degrees, relying on the image mosaic technique, our system can seamlessly integrate 4-channel videos into a panorama video. The panorama video enable drivers to observe everywhere around a car as far as three meters from a top view. We performed experiments in a laboratory environment. Preliminary results show that our system can eliminate vision dead zone completely. Additionally, the real-time performance of our system can satisfy requirements for practical use.

  1. Peripheral Sympathectomy for Raynaud's Phenomenon: A Salvage Procedure

    Directory of Open Access Journals (Sweden)

    Wen-Her Wang

    2006-10-01

    Full Text Available We retrospectively reviewed the effectiveness of peripheral sympathectomy for severe Raynaud's phenomenon. In this study, a total of 14 digits from six patients with chronic digital ischemic change were included. All patients had pain, ulcer, or gangrenous change in the affected digits and were unresponsive to pharmacologic or other nonsurgical therapies. In all cases, angiography showed multifocal arterial lesions, so microvascular reconstruction was unfeasible. Peripheral sympathectomy was performed as a salvage procedure to prevent digit amputation. The results were analyzed according to reduction of pain, healing of ulcers, and prevention of amputation. In 12 of the 14 digits, the ulcers healed and amputation was avoided. In the other two digits, the ulcers improved and progressive gangrene was limited. As a salvage procedure for Raynaud's phenomenon recalcitrant to conservative treatment, peripheral sympathectomy improves perfusion to ischemic digits and enables amputation to be avoided.

  2. Rotational Kinematics Model Based Adaptive Particle Filter for Robust Human Tracking in Thermal Omnidirectional Vision

    Directory of Open Access Journals (Sweden)

    Yazhe Tang

    2015-01-01

    Full Text Available This paper presents a novel surveillance system named thermal omnidirectional vision (TOV system which can work in total darkness with a wild field of view. Different to the conventional thermal vision sensor, the proposed vision system exhibits serious nonlinear distortion due to the effect of the quadratic mirror. To effectively model the inherent distortion of omnidirectional vision, an equivalent sphere projection is employed to adaptively calculate parameterized distorted neighborhood of an object in the image plane. With the equivalent projection based adaptive neighborhood calculation, a distortion-invariant gradient coding feature is proposed for thermal catadioptric vision. For robust tracking purpose, a rotational kinematic modeled adaptive particle filter is proposed based on the characteristic of omnidirectional vision, which can handle multiple movements effectively, including the rapid motions. Finally, the experiments are given to verify the performance of the proposed algorithm for human tracking in TOV system.

  3. Basic design principles of colorimetric vision systems

    Science.gov (United States)

    Mumzhiu, Alex M.

    1998-10-01

    Color measurement is an important part of overall production quality control in textile, coating, plastics, food, paper and other industries. The color measurement instruments such as colorimeters and spectrophotometers, used for production quality control have many limitations. In many applications they cannot be used for a variety of reasons and have to be replaced with human operators. Machine vision has great potential for color measurement. The components for color machine vision systems, such as broadcast quality 3-CCD cameras, fast and inexpensive PCI frame grabbers, and sophisticated image processing software packages are available. However the machine vision industry has only started to approach the color domain. The few color machine vision systems on the market, produced by the largest machine vision manufacturers have very limited capabilities. A lack of understanding that a vision based color measurement system could fail if it ignores the basic principles of colorimetry is the main reason for the slow progress of color vision systems. the purpose of this paper is to clarify how color measurement principles have to be applied to vision systems and how the electro-optical design features of colorimeters have to be modified in order to implement them for vision systems. The subject of this presentation far exceeds the limitations of a journal paper so only the most important aspects will be discussed. An overview of the major areas of applications for colorimetric vision system will be discussed. Finally, the reasons why some customers are happy with their vision systems and some are not will be analyzed.

  4. Vision based systems for UAV applications

    CERN Document Server

    Kuś, Zygmunt

    2013-01-01

    This monograph is motivated by a significant number of vision based algorithms for Unmanned Aerial Vehicles (UAV) that were developed during research and development projects. Vision information is utilized in various applications like visual surveillance, aim systems, recognition systems, collision-avoidance systems and navigation. This book presents practical applications, examples and recent challenges in these mentioned application fields. The aim of the book is to create a valuable source of information for researchers and constructors of solutions utilizing vision from UAV. Scientists, researchers and graduate students involved in computer vision, image processing, data fusion, control algorithms, mechanics, data mining, navigation and IC can find many valuable, useful and practical suggestions and solutions. The latest challenges for vision based systems are also presented.

  5. Robotics Vision-based Heuristic Reasoning for Underwater Target Tracking and Navigation

    Directory of Open Access Journals (Sweden)

    Chua Kia

    2005-09-01

    Full Text Available This paper presents a robotics vision-based heuristic reasoning system for underwater target tracking and navigation. This system is introduced to improve the level of automation of underwater Remote Operated Vehicles (ROVs operations. A prototype which combines computer vision with an underwater robotics system is successfully designed and developed to perform target tracking and intelligent navigation. This study focuses on developing image processing algorithms and fuzzy inference system for the analysis of the terrain. The vision system developed is capable of interpreting underwater scene by extracting subjective uncertainties of the object of interest. Subjective uncertainties are further processed as multiple inputs of a fuzzy inference system that is capable of making crisp decisions concerning where to navigate. The important part of the image analysis is morphological filtering. The applications focus on binary images with the extension of gray-level concepts. An open-loop fuzzy control system is developed for classifying the traverse of terrain. The great achievement is the system's capability to recognize and perform target tracking of the object of interest (pipeline in perspective view based on perceived condition. The effectiveness of this approach is demonstrated by computer and prototype simulations. This work is originated from the desire to develop robotics vision system with the ability to mimic the human expert's judgement and reasoning when maneuvering ROV in the traverse of the underwater terrain.

  6. Robotics Vision-based Heuristic Reasoning for Underwater Target Tracking and Navigation

    Directory of Open Access Journals (Sweden)

    Chua Kia

    2008-11-01

    Full Text Available This paper presents a robotics vision-based heuristic reasoning system for underwater target tracking and navigation. This system is introduced to improve the level of automation of underwater Remote Operated Vehicles (ROVs operations. A prototype which combines computer vision with an underwater robotics system is successfully designed and developed to perform target tracking and intelligent navigation. This study focuses on developing image processing algorithms and fuzzy inference system for the analysis of the terrain. The vision system developed is capable of interpreting underwater scene by extracting subjective uncertainties of the object of interest. Subjective uncertainties are further processed as multiple inputs of a fuzzy inference system that is capable of making crisp decisions concerning where to navigate. The important part of the image analysis is morphological filtering. The applications focus on binary images with the extension of gray-level concepts. An open-loop fuzzy control system is developed for classifying the traverse of terrain. The great achievement is the system's capability to recognize and perform target tracking of the object of interest (pipeline in perspective view based on perceived condition. The effectiveness of this approach is demonstrated by computer and prototype simulations. This work is originated from the desire to develop robotics vision system with the ability to mimic the human expert's judgement and reasoning when maneuvering ROV in the traverse of the underwater terrain.

  7. LATE VISION: PROCESSES AND EPISTEMIC STATUS

    Directory of Open Access Journals (Sweden)

    Athanassios eRaftopoulos

    2011-12-01

    Full Text Available In this paper, I examine the processes that occur in late vision and address the problem of whether late vision should be construed as a properly speaking perceptual stage, or as a thought-like discursive stage. Specifically, I argue that late vision, its (partly conceptual nature notwithstanding, neither is constituted by nor does it implicate what I call pure thoughts, that is, propositional structures that are formed in the cognitive areas of the brain through, and participate in, discursive reasoning and inferences. At the same time, the output of late vision, namely an explicit belief concerning the identity and category membership of an object (that is, a recognitional belief or its features, eventually enters into discursive reasoning. Using Jackendoff’s distinction between visual awareness, which characterizes perception, and visual understanding, which characterizes pure thought, I claim that the contents of late vision belong to visual awareness and not to visual understanding and that although late vision implicates beliefs, either implicit or explicit, these beliefs are hybrid visual/conceptual constructs and not pure thoughts. Distinguishing between these hybrid representations and pure thoughts and delineating the nature of the representations of late vision lays the ground for examining, among other things, the process of conceptualization that occurs in visual processing and the way concepts modulate perceptual content affecting either its representational or phenomenal character. I also do not discuss the epistemological relations between the representations of late vision and the perceptual judgments they ‘support’, or ‘guide’ or ‘render possible’ or ‘evidence’ or ‘entitle’. However, the specification of the epistemology of late vision lays the ground for attacking that problem as well.

  8. Comparison of Three Smart Camera Architectures for Real-Time Machine Vision System

    Directory of Open Access Journals (Sweden)

    Abdul Waheed Malik

    2013-12-01

    Full Text Available This paper presents a machine vision system for real-time computation of distance and angle of a camera from a set of reference points located on a target board. Three different smart camera architectures were explored to compare performance parameters such as power consumption, frame speed and latency. Architecture 1 consists of hardware machine vision modules modeled at Register Transfer (RT level and a soft-core processor on a single FPGA chip. Architecture 2 is commercially available software based smart camera, Matrox Iris GT. Architecture 3 is a two-chip solution composed of hardware machine vision modules on FPGA and an external microcontroller. Results from a performance comparison show that Architecture 2 has higher latency and consumes much more power than Architecture 1 and 3. However, Architecture 2 benefits from an easy programming model. Smart camera system with FPGA and external microcontroller has lower latency and consumes less power as compared to single FPGA chip having hardware modules and soft-core processor.

  9. Colour, vision and ergonomics.

    Science.gov (United States)

    Pinheiro, Cristina; da Silva, Fernando Moreira

    2012-01-01

    This paper is based on a research project - Visual Communication and Inclusive Design-Colour, Legibility and Aged Vision, developed at the Faculty of Architecture of Lisbon. The research has the aim of determining specific design principles to be applied to visual communication design (printed) objects, in order to be easily read and perceived by all. This study target group was composed by a selection of socially active individuals, between 55 and 80 years, and we used cultural events posters as objects of study and observation. The main objective is to overlap the study of areas such as colour, vision, older people's colour vision, ergonomics, chromatic contrasts, typography and legibility. In the end we will produce a manual with guidelines and information to apply scientific knowledge into the communication design projectual practice. Within the normal aging process, visual functions gradually decline; the quality of vision worsens, colour vision and contrast sensitivity are also affected. As people's needs change along with age, design should help people and communities, and improve life quality in the present. Applying principles of visually accessible design and ergonomics, the printed design objects, (or interior spaces, urban environments, products, signage and all kinds of visually information) will be effective, easier on everyone's eyes not only for visually impaired people but also for all of us as we age.

  10. Influence of sports vision techniques on adult male rugby players ...

    African Journals Online (AJOL)

    Sport has become increasingly competitive and this places enormous pressure on sportsmen to perform at their absolute best. For athletes to achieve their greatest potentials, aspects of sport such as reaction time and hand-eye coordination need to be at their peaks. Sports vision aims to enhance performance through a ...

  11. 77 FR 51846 - Qualification of Drivers; Exemption Applications; Vision

    Science.gov (United States)

    2012-08-27

    ... past 3 years. Recent driving performance is especially important in evaluating future safety, according... achieved a record of safety while driving with their vision impairment, demonstrating the likelihood that... DEPARTMENT OF TRANSPORTATION Federal Motor Carrier Safety Administration [Docket No. FMCSA-2012...

  12. Simple Experiments on the Physics of Vision: The Retina

    Science.gov (United States)

    Cortel, Adolf

    2005-01-01

    Many simple experiments can be performed in the classroom to explore the physics of vision. Students can learn of the two types of receptive cells (rods and cones), their distribution on the retina and the existence of the blind spot.

  13. Reinforcement learning in computer vision

    Science.gov (United States)

    Bernstein, A. V.; Burnaev, E. V.

    2018-04-01

    Nowadays, machine learning has become one of the basic technologies used in solving various computer vision tasks such as feature detection, image segmentation, object recognition and tracking. In many applications, various complex systems such as robots are equipped with visual sensors from which they learn state of surrounding environment by solving corresponding computer vision tasks. Solutions of these tasks are used for making decisions about possible future actions. It is not surprising that when solving computer vision tasks we should take into account special aspects of their subsequent application in model-based predictive control. Reinforcement learning is one of modern machine learning technologies in which learning is carried out through interaction with the environment. In recent years, Reinforcement learning has been used both for solving such applied tasks as processing and analysis of visual information, and for solving specific computer vision problems such as filtering, extracting image features, localizing objects in scenes, and many others. The paper describes shortly the Reinforcement learning technology and its use for solving computer vision problems.

  14. Personal and organisational vision supporting leadership in a team-based transport environment

    Directory of Open Access Journals (Sweden)

    Theuns F.J. Oosthuizen

    2012-11-01

    Full Text Available Leadership in an operational environment requires operational employees to take on responsibility as leaders. This leadership role could vary from self-leadership to team leadership with personal and organisational vision as key drivers for operational leadership performance. The research population included operational employees working in a transport environment who attended a leadership development seminar. A census was conducted using a questionnaire-based empirical research approach. Data analysis was conducted using SPSS, and the results were analysed. Responses indicate the development of an awareness of the importance of values and vision in order to establish effective leadership practices through the leadership development programme. Research confirmed the importance of vision as a key driver in operational leadership in this context. Further skill development is required on how to align personal values and vision with that of the organisation (department within which operational employees function.

  15. Tumors of peripheral nerves

    International Nuclear Information System (INIS)

    Ho, Michael; Lutz, Amelie M.

    2017-01-01

    Differentiation between malignant and benign tumors of peripheral nerves in the early stages is challenging; however, due to the unfavorable prognosis of malignant tumors early identification is required. To show the possibilities for detection, differential diagnosis and clinical management of peripheral nerve tumors by imaging appearance in magnetic resonance (MR) neurography. Review of current literature available in PubMed and MEDLINE, supplemented by the authors' own observations in clinical practice. Although not pathognomonic, several imaging features have been reported for a differentiation between distinct peripheral nerve tumors. The use of MR neurography enables detection and initial differential diagnosis in tumors of peripheral nerves. Furthermore, it plays an important role in clinical follow-up, targeted biopsy and surgical planning. (orig.) [de

  16. Performance of Global-Appearance Descriptors in Map Building and Localization Using Omnidirectional Vision

    Directory of Open Access Journals (Sweden)

    Luis Payá

    2014-02-01

    Full Text Available Map building and localization are two crucial abilities that autonomous robots must develop. Vision sensors have become a widespread option to solve these problems. When using this kind of sensors, the robot must extract the necessary information from the scenes to build a representation of the environment where it has to move and to estimate its position and orientation with robustness. The techniques based on the global appearance of the scenes constitute one of the possible approaches to extract this information. They consist in representing each scene using only one descriptor which gathers global information from the scene. These techniques present some advantages comparing to other classical descriptors, based on the extraction of local features. However, it is important a good configuration of the parameters to reach a compromise between computational cost and accuracy. In this paper we make an exhaustive comparison among some global appearance descriptors to solve the mapping and localization problem. With this aim, we make use of several image sets captured in indoor environments under realistic working conditions. The datasets have been collected using an omnidirectional vision sensor mounted on the robot.

  17. Low-Resolution Vision-at the Hub of Eye Evolution.

    Science.gov (United States)

    Nilsson, Dan-E; Bok, Michael J

    2017-11-01

    Simple roles for photoreception are likely to have preceded more demanding ones such as vision. The driving force behind this evolution is the improvement and elaboration of animal behaviors using photoreceptor input. Because the basic role for all senses aimed at the external world is to guide behavior, we argue here that understanding this "behavioral drive" is essential for unraveling the evolutionary past of the senses. Photoreception serves many different types of behavior, from simple shadow responses to visual communication. Based on minimum performance requirements for different types of tasks, photoreceptors have been argued to have evolved from non-directional receptors, via directional receptors, to low-resolution vision, and finally to high-resolution vision. Through this sequence, the performance requirements on the photoreceptors have gradually changed from broad to narrow angular sensitivity, from slow to fast response, and from low to high contrast sensitivity during the evolution from simple to more advanced and demanding behaviors. New behaviors would only evolve if their sensory performance requirements to some degree overlap with the requirements of already existing behaviors. This need for sensory "performance continuity" must have determined the order by which behaviors have evolved and thus been an important factor guiding animal evolution. Naturally, new behaviors are most likely to evolve from already existing behaviors with similar neural processing needs and similar motor responses, pointing to "neural continuity" as another guiding factor in sensory evolution. Here we use these principles to derive an evolutionary tree for behaviors driven by photoreceptor input. © The Author 2017. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved. For permissions please email: journals.permissions@oup.com.

  18. Peripheral Neuropathy in Spinocerebellar Ataxia Type 1, 2, 3, and 6.

    Science.gov (United States)

    Linnemann, Christoph; Tezenas du Montcel, Sophie; Rakowicz, Maryla; Schmitz-Hübsch, Tanja; Szymanski, Sandra; Berciano, Jose; van de Warrenburg, Bart P; Pedersen, Karine; Depondt, Chantal; Rola, Rafal; Klockgether, Thomas; García, Antonio; Mutlu, Gurkan; Schöls, Ludger

    2016-04-01

    Spinocerebellar ataxias (SCAs) are characterized by autosomal dominantly inherited progressive ataxia but are clinically heterogeneous due to variable involvement of non-cerebellar parts of the nervous system. Non-cerebellar symptoms contribute significantly to the burden of SCAs, may guide the clinician to the underlying genetic subtype, and might be useful markers to monitor disease. Peripheral neuropathy is frequently observed in SCA, but subtype-specific features and subclinical manifestations have rarely been evaluated. We performed a multicenter nerve conduction study with 162 patients with genetically confirmed SCA1, SCA2, SCA3, and SCA6. The study proved peripheral nerves to be involved in the neurodegenerative process in 82 % of SCA1, 63 % of SCA2, 55 % of SCA3, and 22 % of SCA6 patients. Most patients of all subtypes revealed affection of both sensory and motor fibers. Neuropathy was most frequently of mixed type with axonal and demyelinating characteristics in all SCA subtypes. However, nerve conduction velocities of SCA1 patients were slower compared to other genotypes. SCA6 patients revealed less axonal damage than patients with other subtypes. No influence of CAG repeat length or biometric determinants on peripheral neuropathy could be identified in SCA1, SCA3, and SCA6. In SCA2, earlier onset and more severe ataxia were associated with peripheral neuropathy. We proved peripheral neuropathy to be a frequent site of the neurodegenerative process in all common SCA subtypes. Since damage to peripheral nerves is readily assessable by electrophysiological means, nerve conduction studies should be performed in a longitudinal approach to assess these parameters as potential progression markers.

  19. INL Vision and Strategy 2015

    International Nuclear Information System (INIS)

    Pillai, Rekha Sukamar

    2015-01-01

    This Laboratory vision and strategy presents INL's vision and strategy for the Laboratory and is our introduction to a special place dedicated to improving our nation's energy security future.

  20. Peripheral dentinogenic ghost cell tumor

    Directory of Open Access Journals (Sweden)

    Sushant S Kamat

    2013-01-01

    Full Text Available Dentinogenic ghost cell tumors (DGCT are uncommon lesions mainly with rare peripheral types. This report presents a case of peripheral DGCT on the left side of the mandibular alveolar ridge of a heavy smoker, a 68-year-old man, with main presenting feature as a mild pain. Submandibular lymphadenopathy and radiological "saucerization" were evident. Differential diagnosis included fibroma, neurofibroma, peripheral ameloblastoma, peripheral odontogenic fibroma, and peripheral giant cell granuloma. Histologically, ameloblastoma-like epithelial elements were seen in association with grouped ghost cells. Proliferating polyhedral cells and stellate reticulum-like cells with various densities were spread over a wide range of the field. The lesion was curetted and after 2 years of follow up, it did not recur.

  1. National Hydrogen Vision Meeting Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    None

    2001-11-01

    This document provides presentations and summaries of the notes from the National Hydrogen Vision Meeting''s facilitated breakout sessions. The Vision Meeting, which took place November 15-16, 2001, kicked off the public-private partnership that will pave the way to a more secure and cleaner energy future for America. These proceedings were compiled into a formal report, A National Vision of America''s Transition to a Hydrogen Economy - To 2030 and Beyond, which is also available online.

  2. Enhanced peripheral visual processing in congenitally deaf humans is supported by multiple brain regions, including primary auditory cortex

    Directory of Open Access Journals (Sweden)

    Gregory D. Scott

    2014-03-01

    Full Text Available Brain reorganization associated with altered sensory experience clarifies the critical role of neuroplasticity in development. An example is enhanced peripheral visual processing associated with congenital deafness, but the neural systems supporting this have not been fully characterized. A gap in our understanding of deafness-enhanced peripheral vision is the contribution of primary auditory cortex. Previous studies of auditory cortex that use anatomical normalization across participants were limited by inter-subject variability of Heschl’s gyrus. In addition to reorganized auditory cortex (cross-modal plasticity, a second gap in our understanding is the contribution of altered modality-specific cortices (visual intramodal plasticity in this case, as well as supramodal and multisensory cortices, especially when target detection is required across contrasts. Here we address these gaps by comparing fMRI signal change for peripheral versus perifoveal visual stimulation (11-15° vs. 2°-7° in congenitally deaf and hearing participants in a blocked experimental design with two analytical approaches: a Heschl’s gyrus region of interest analysis and a whole brain analysis. Our results using individually-defined primary auditory cortex (Heschl’s gyrus indicate that fMRI signal change for more peripheral stimuli was greater than perifoveal in deaf but not in hearing participants. Whole-brain analyses revealed differences between deaf and hearing participants for peripheral versus perifoveal visual processing in extrastriate visual cortex including primary auditory cortex, MT+/V5, superior-temporal auditory and multisensory and/or supramodal regions, such as posterior parietal cortex, frontal eye fields, anterior cingulate, and supplementary eye fields. Overall, these data demonstrate the contribution of neuroplasticity in multiple systems including primary auditory cortex, supramodal and multisensory regions, to altered visual processing in

  3. The Vision Thing in Higher Education.

    Science.gov (United States)

    Keller, George

    1995-01-01

    It is argued that while the concept of "vision" in higher education has been met with disdain, criticism is based on misconceptions of vision's nature and role--that vision requires a charismatic administrator and that visionaries are dreamers. Educators and planners are urged to use imaginative thinking to connect the institution's and staff's…

  4. What is vision Hampton Roads?

    Science.gov (United States)

    2010-01-01

    What is Vision Hampton Roads? : Vision Hampton Roads is... : A regionwide economic development strategy based on the collective strengths of all : localities of Hampton Roads, created with the input of business, academia, nonprofits, : government,...

  5. Minimum training requirement in ultrasound imaging of peripheral arterial disease.

    Science.gov (United States)

    Eiberg, J P; Hansen, M A; Grønvall Rasmussen, J B; Schroeder, T V

    2008-09-01

    To demonstrate the minimum training requirement when performing ultrasound of peripheral arterial disease. Prospective and blinded comparative study. 100 limbs in 100 consecutive patients suffering from peripheral arterial disease, 74% suffering critical limb ischemia, were enrolled during a 9 months period. One physician with limited ultrasound experience performed all the ultrasound examinations of the arteries of the most symptomatic limb. Before enrolling any patients 15 duplex ultrasound examinations were performed supervised by an experienced vascular technologist. All patients had a digital subtraction arteriography performed by an experienced vascular radiologist, unaware of the ultrasound result. The number of insufficiently insonated segments (non-diagnostic segments) was significantly reduced during the study; from 9% among the initial 50 limbs to 2% among the last 50 limbs (Pultrasound and arteriography from the initial 50 patients (overall Kappa=0.66, (95%-CI: 0.60-0.72); supragenicular Kappa=0.73 (95%-CI: 0.64-0.82); infragenicular Kappa=0.61 (95%-CI: 0.54-0.69)) to the last 50 patients (overall Kappa=0.66 (95%-CI: 0.60-0.72), supragenicular Kappa=0.67 (95%-CI: 0.57-0.76); infragenicular Kappa=0.66 (95%-CI: 0.58-0.73)). The minimum training requirement in ultrasound imaging of peripheral arterial disease appears to be less than 50 ultrasound examinations (probably only 15 examinations) for the supragenicular segments and 100 examinations for the infragenicular segments.

  6. Computer vision syndrome (CVS) - Thermographic Analysis

    Science.gov (United States)

    Llamosa-Rincón, L. E.; Jaime-Díaz, J. M.; Ruiz-Cardona, D. F.

    2017-01-01

    The use of computers has reported an exponential growth in the last decades, the possibility of carrying out several tasks for both professional and leisure purposes has contributed to the great acceptance by the users. The consequences and impact of uninterrupted tasks with computers screens or displays on the visual health, have grabbed researcher’s attention. When spending long periods of time in front of a computer screen, human eyes are subjected to great efforts, which in turn triggers a set of symptoms known as Computer Vision Syndrome (CVS). Most common of them are: blurred vision, visual fatigue and Dry Eye Syndrome (DES) due to unappropriate lubrication of ocular surface when blinking decreases. An experimental protocol was de-signed and implemented to perform thermographic studies on healthy human eyes during exposure to dis-plays of computers, with the main purpose of comparing the existing differences in temperature variations of healthy ocular surfaces.

  7. 76 FR 53710 - Qualification of Drivers; Exemption Applications; Vision

    Science.gov (United States)

    2011-08-29

    ... for the past 3 years. Recent driving performance is especially important in evaluating future safety... achieved a record of safety while driving with their vision impairment, demonstrating the likelihood that... DEPARTMENT OF TRANSPORTATION Federal Motor Carrier Safety Administration [Docket No. FMCSA-2011...

  8. Complementary therapies for peripheral arterial disease: systematic review.

    Science.gov (United States)

    Pittler, Max H; Ernst, Edzard

    2005-07-01

    While peripheral arterial disease (PAD) affects a considerable proportion of patients in the primary care setting, there is a high level of use of complementary treatment options. The aim was to assess the effectiveness of any type of complementary therapy for peripheral arterial disease. A systematic review was performed. Literature searches were conducted on Medline, Embase, Amed, and the Cochrane Library until December 2004. Hand-searches of medical journals and bibliographies were conducted. There were no restrictions regarding the language of publication. The screening of studies, selection, data extraction, the assessment of methodologic quality and validation were performed independently by the two reviewers. Data from randomized controlled trials, and systematic reviews and meta-analyses, which based their findings on the results of randomized controlled trials were included. Seven systematic reviews and meta-analyses and three additional randomized controlled trials met the inclusion criteria and were reviewed. The evidence relates to acupuncture, biofeedback, chelation therapy, CO(2)-applications and the dietary supplements Allium sativum (garlic), Ginkgo biloba (ginkgo), omega-3 fatty acids, padma 28 and Vitamin E. Most studies included only patients with peripheral arterial disease in Fontaine stage II (intermittent claudication). The reviewed RCTs, systematic reviews and meta-analyses which based their findings on the results of RCTs suggest that G. biloba is effective compared with placebo for patients with intermittent claudication. Evidence also suggests that padma 28 is effective for intermittent claudication, although more data are required to confirm these findings. For all other complementary treatment options there is no evidence beyond reasonable doubt to suggest effectiveness for patients with peripheral arterial disease.

  9. Predicting Vision-Related Disability in Glaucoma.

    Science.gov (United States)

    Abe, Ricardo Y; Diniz-Filho, Alberto; Costa, Vital P; Wu, Zhichao; Medeiros, Felipe A

    2018-01-01

    To present a new methodology for investigating predictive factors associated with development of vision-related disability in glaucoma. Prospective, observational cohort study. Two hundred thirty-six patients with glaucoma followed up for an average of 4.3±1.5 years. Vision-related disability was assessed by the 25-item National Eye Institute Visual Function Questionnaire (NEI VFQ-25) at baseline and at the end of follow-up. A latent transition analysis model was used to categorize NEI VFQ-25 results and to estimate the probability of developing vision-related disability during follow-up. Patients were tested with standard automated perimetry (SAP) at 6-month intervals, and evaluation of rates of visual field change was performed using mean sensitivity (MS) of the integrated binocular visual field. Baseline disease severity, rate of visual field loss, and duration of follow-up were investigated as predictive factors for development of disability during follow-up. The relationship between baseline and rates of visual field deterioration and the probability of vision-related disability developing during follow-up. At baseline, 67 of 236 (28%) glaucoma patients were classified as disabled based on NEI VFQ-25 results, whereas 169 (72%) were classified as nondisabled. Patients classified as nondisabled at baseline had 14.2% probability of disability developing during follow-up. Rates of visual field loss as estimated by integrated binocular MS were almost 4 times faster for those in whom disability developed versus those in whom it did not (-0.78±1.00 dB/year vs. -0.20±0.47 dB/year, respectively; P disability developing over time (odds ratio [OR], 1.34; 95% confidence interval [CI], 1.06-1.70; P = 0.013). In addition, each 0.5-dB/year faster rate of loss of binocular MS during follow-up was associated with a more than 3.5 times increase in the risk of disability developing (OR, 3.58; 95% CI, 1.56-8.23; P = 0.003). A new methodology for classification and analysis

  10. Using Vision System Technologies for Offset Approaches in Low Visibility Operations

    Science.gov (United States)

    Kramer, Lynda J.; Bailey, Randall E.; Ellis, Kyle K.

    2015-01-01

    Flight deck-based vision systems, such as Synthetic Vision Systems (SVS) and Enhanced Flight Vision Systems (EFVS), have the potential to provide additional margins of safety for aircrew performance and enable the implementation of operational improvements for low visibility surface, arrival, and departure operations in the terminal environment with equivalent efficiency to visual operations. Twelve air transport-rated crews participated in a motion-base simulation experiment to evaluate the use of SVS/EFVS in Next Generation Air Transportation System low visibility approach and landing operations at Chicago O'Hare airport. Three monochromatic, collimated head-up display (HUD) concepts (conventional HUD, SVS HUD, and EFVS HUD) and three instrument approach types (straight-in, 3-degree offset, 15-degree offset) were experimentally varied to test the efficacy of the SVS/EFVS HUD concepts for offset approach operations. The findings suggest making offset approaches in low visibility conditions with an EFVS HUD or SVS HUD appear feasible. Regardless of offset approach angle or HUD concept being flown, all approaches had comparable ILS tracking during the instrument segment and were within the lateral confines of the runway with acceptable sink rates during the visual segment of the approach. Keywords: Enhanced Flight Vision Systems; Synthetic Vision Systems; Head-up Display; NextGen

  11. Temporary effects of alcohol on color vision

    Science.gov (United States)

    Geniusz, Maciej K.; Geniusz, Malwina; Szmigiel, Marta; Przeździecka-Dołyk, Joanna

    2017-09-01

    The color vision has been described as one to be very sensitive to the intake of several chemicals. The present research reviews the published literature that is concerned with color vision impairment due to alcohol. Most of this research considers people under long-term effects of alcohol. However, there is little information about temporary effects of alcohol on color vision. A group of ten volunteers aged 18-40 was studied. During the study levels of alcohol in the body were tested with a standard breathalyzer while color vision were studied using Farnsworth Munsell 100 Hue Color Vision Tests. Keywords: Col

  12. Suitability of School Textbooks for 5 to 7 Year Old Children with Colour Vision Deficiencies

    Science.gov (United States)

    Torrents, Aurora; Bofill, Francesc; Cardona, Genis

    2011-01-01

    Purpose: The aim of the present study was to determine, through colorimetric analysis, whether school textbooks for children aged 5 to 7 years contained tasks requiring normal colour vision discrimination for their resolution. In addition, the performance of a group of observers with diverse colour vision deficiencies was evaluated while…

  13. Origins of strabismus and loss of binocular vision

    Science.gov (United States)

    Bui Quoc, Emmanuel; Milleret, Chantal

    2014-01-01

    Strabismus is a frequent ocular disorder that develops early in life in humans. As a general rule, it is characterized by a misalignment of the visual axes which most often appears during the critical period of visual development. However other characteristics of strabismus may vary greatly among subjects, for example, being convergent or divergent, horizontal or vertical, with variable angles of deviation. Binocular vision may also vary greatly. Our main goal here is to develop the idea that such “polymorphy” reflects a wide variety in the possible origins of strabismus. We propose that strabismus must be considered as possibly resulting from abnormal genetic and/or acquired factors, anatomical and/or functional abnormalities, in the sensory and/or the motor systems, both peripherally and/or in the brain itself. We shall particularly develop the possible “central” origins of strabismus. Indeed, we are convinced that it is time now to open this “black box” in order to move forward. All of this will be developed on the basis of both presently available data in literature (including most recent data) and our own experience. Both data in biology and medicine will be referred to. Our conclusions will hopefully help ophthalmologists to better understand strabismus and to develop new therapeutic strategies in the future. Presently, physicians eliminate or limit the negative effects of such pathology both on the development of the visual system and visual perception through the use of optical correction and, in some cases, extraocular muscle surgery. To better circumscribe the problem of the origins of strabismus, including at a cerebral level, may improve its management, in particular with respect to binocular vision, through innovating tools by treating the pathology at the source. PMID:25309358

  14. Interoperability Strategic Vision

    Energy Technology Data Exchange (ETDEWEB)

    Widergren, Steven E.; Knight, Mark R.; Melton, Ronald B.; Narang, David; Martin, Maurice; Nordman, Bruce; Khandekar, Aditya; Hardy, Keith S.

    2018-02-28

    The Interoperability Strategic Vision whitepaper aims to promote a common understanding of the meaning and characteristics of interoperability and to provide a strategy to advance the state of interoperability as applied to integration challenges facing grid modernization. This includes addressing the quality of integrating devices and systems and the discipline to improve the process of successfully integrating these components as business models and information technology improve over time. The strategic vision for interoperability described in this document applies throughout the electric energy generation, delivery, and end-use supply chain. Its scope includes interactive technologies and business processes from bulk energy levels to lower voltage level equipment and the millions of appliances that are becoming equipped with processing power and communication interfaces. A transformational aspect of a vision for interoperability in the future electric system is the coordinated operation of intelligent devices and systems at the edges of grid infrastructure. This challenge offers an example for addressing interoperability concerns throughout the electric system.

  15. Robotic vision system for random bin picking with dual-arm robots

    Directory of Open Access Journals (Sweden)

    Kang Sangseung

    2016-01-01

    Full Text Available Random bin picking is one of the most challenging industrial robotics applications available. It constitutes a complicated interaction between the vision system, robot, and control system. For a packaging operation requiring a pick-and-place task, the robot system utilized should be able to perform certain functions for recognizing the applicable target object from randomized objects in a bin. In this paper, we introduce a robotic vision system for bin picking using industrial dual-arm robots. The proposed system recognizes the best object from randomized target candidates based on stereo vision, and estimates the position and orientation of the object. It then sends the result to the robot control system. The system was developed for use in the packaging process of cell phone accessories using dual-arm robots.

  16. Peripheral retinal degenerations and the risk of retinal detachment.

    Science.gov (United States)

    Lewis, Hilel

    2003-07-01

    To review the degenerative diseases of the peripheral retina in relationship with the risk to develop a rhegmatogenous retinal detachment and to present recommendations for use in eyes at increased risk of developing a retinal detachment. Focused literature review and author's clinical experience. Retinal degenerations are common lesions involving the peripheral retina, and most of them are clinically insignificant. Lattice degeneration, degenerative retinoschisis, cystic retinal tufts, and, rarely, zonular traction tufts, can result in a rhegmatogenous retinal detachment. Therefore, these lesions have been considered for prophylactic therapy; however, adequate studies have not been performed to date. Well-designed, prospective, randomized clinical studies are necessary to determine the benefit-risk ratio of prophylactic treatment. In the meantime, the evidence available suggests that most of the peripheral retinal degenerations should not be treated except in rare, high-risk situations.

  17. Influence of dosing times on cisplatin-induced peripheral neuropathy in rats

    International Nuclear Information System (INIS)

    Seto, Yoshihiro; Okazaki, Fumiyasu; Horikawa, Keiji; Zhang, Jing; Sasaki, Hitoshi; To, Hideto

    2016-01-01

    Although cis-diamminedichloro-platinum (CDDP) exhibits strong therapeutic effects in cancer chemotherapy, its adverse effects such as peripheral neuropathy, nephropathy, and vomiting are dose-limiting factors. Previous studies reported that chronotherapy decreased CDDP-induced nephropathy and vomiting. In the present study, we investigated the influence of dosing times on CDDP-induced peripheral neuropathy in rats. CDDP (4 mg/kg) was administered intravenously at 5:00 or 17:00 every 7 days for 4 weeks to male Sprague–Dawley rats, and saline was given to the control group. To assess the dosing time dependency of peripheral neuropathy, von-Frey test and hot-plate test were performed. In order to estimate hypoalgesia, the hot-plate test was performed in rats administered CDDP weekly for 4 weeks. On day 28, the withdrawal latency to thermal stimulation was significantly prolonged in the 17:00-treated group than in the control and 5:00-treated groups. When the von-Frey test was performed to assess mechanical allodynia, the withdrawal threshold was significantly lower in the 5:00 and 17:00-treated groups than in the control group on day 6 after the first CDDP dose. The 5:00-treated group maintained allodynia throughout the experiment with the repeated administration of CDDP, whereas the 17:00-treated group deteriorated from allodynia to hypoalgesia. It was revealed that the severe of CDDP-induced peripheral neuropathy was inhibited in the 5:00-treated group, whereas CDDP-treated groups exhibited mechanical allodynia. These results suggested that the selection of an optimal dosing time ameliorated CDDP-induced peripheral neuropathy. The online version of this article (doi:10.1186/s12885-016-2777-0) contains supplementary material, which is available to authorized users

  18. Colour vision abnormality as the only manifestation of normal pressure hydrocephalus.

    Science.gov (United States)

    Asensio-Sánchez, V M; Martín-Prieto, A

    2018-01-01

    The case is presented of a 73-year-old male patient who referred to having black and white vision. Computed tomography showed normal pressure hydrocephalus (NPH). Magnetic resonance imaging was not performed because the patient refused to undergo further examinations. Achromatopsia may be the first or only NPH symptom. It may be prudent to ask patients with NPH regarding colour vision. Copyright © 2017 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  19. Pleiades Visions

    Science.gov (United States)

    Whitehouse, M.

    2016-01-01

    Pleiades Visions (2012) is my new musical composition for organ that takes inspiration from traditional lore and music associated with the Pleiades (Seven Sisters) star cluster from Australian Aboriginal, Native American, and Native Hawaiian cultures. It is based on my doctoral dissertation research incorporating techniques from the fields of ethnomusicology and cultural astronomy; this research likely represents a new area of inquiry for both fields. This large-scale work employs the organ's vast sonic resources to evoke the majesty of the night sky and the expansive landscapes of the homelands of the above-mentioned peoples. Other important themes in Pleiades Visions are those of place, origins, cosmology, and the creation of the world.

  20. Enhanced operator perception through 3D vision and haptic feedback

    Science.gov (United States)

    Edmondson, Richard; Light, Kenneth; Bodenhamer, Andrew; Bosscher, Paul; Wilkinson, Loren

    2012-06-01

    Polaris Sensor Technologies (PST) has developed a stereo vision upgrade kit for TALON® robot systems comprised of a replacement gripper camera and a replacement mast zoom camera on the robot, and a replacement display in the Operator Control Unit (OCU). Harris Corporation has developed a haptic manipulation upgrade for TALON® robot systems comprised of a replacement arm and gripper and an OCU that provides haptic (force) feedback. PST and Harris have recently collaborated to integrate the 3D vision system with the haptic manipulation system. In multiple studies done at Fort Leonard Wood, Missouri it has been shown that 3D vision and haptics provide more intuitive perception of complicated scenery and improved robot arm control, allowing for improved mission performance and the potential for reduced time on target. This paper discusses the potential benefits of these enhancements to robotic systems used for the domestic homeland security mission.

  1. Vision in the nocturnal wandering spider Leucorchestris arenicola (Araneae: Sparassidae)

    DEFF Research Database (Denmark)

    Nørgaard, Thomas; Nilsson, Dan-Eric; Henschel, Joh R

    2008-01-01

    At night the Namib Desert spider Leucorchestris arenicola performs long-distance homing across its sand dune habitat. By disabling all or pairs of the spiders' eight eyes we found that homing ability was severely reduced when vision was fully abolished. Vision, therefore, seems to play a key role...... in the posterior and anteriomedian eyes, and at approximately 540 nm in the anteriolateral eyes. Theoretical calculations of photon catches showed that the eyes are likely to employ a combination of spatial and temporal pooling in order to function at night. Under starlit conditions, the raw spatial and temporal...... resolution of the eyes is insufficient for detecting any visual information on structures in the landscape, and bright stars would be the only objects visible to the spiders. However, by summation in space and time, the spiders can rescue enough vision to detect coarse landscape structures. We show that L...

  2. Color vision deficiencies and the child's willingness for visual activity: preliminary research

    Science.gov (United States)

    Geniusz, Malwina; Szmigiel, Marta; Geniusz, Maciej

    2017-09-01

    After a few weeks a newborn baby can recognize high contrasts in colors like black and white. They reach full color vision at the age of circa six months. Matching colors is the next milestone. Most children can do it at the age of two. Good color vision is one of the factors which indicate proper development of a child. Presented research shows the correlation between color vision and visual activity. The color vision of a group of children aged 3-8 was examined with saturated Farnsworth D-15. Fransworth test was performed twice - in a standard version and in a magnetic version. The time of completing standard and magnetic tests was measured. Furthermore, parents of subjects answered questions checking the children's visual activity in 1 - 10 scale. Parents stated whether the child willingly watched books, colored coloring books, put puzzles or liked to play with blocks etc. The Fransworth D-15 test designed for color vision testing can be used to test younger children from the age of 3 years. These are preliminary studies which may be a useful tool for further, more accurate examination on a larger group of subjects.

  3. School Vision of Learning: Urban Setting

    Science.gov (United States)

    Guy, Tiffany A.

    2010-01-01

    In this paper, the author develops her school vision of learning. She explains the theories she used to help develop the vision. The author then goes into detail on the methods she will use to make her vision for a school that prepares urban students for a successful life after high school. She takes into account all the stakeholders and how they…

  4. Computer vision for an autonomous mobile robot

    CSIR Research Space (South Africa)

    Withey, Daniel J

    2015-10-01

    Full Text Available Computer vision systems are essential for practical, autonomous, mobile robots – machines that employ artificial intelligence and control their own motion within an environment. As with biological systems, computer vision systems include the vision...

  5. Application of Computer Vision in Agriculture

    OpenAIRE

    Archana B. Patankar; Priya A. Tayade

    2015-01-01

    Grading and sorting of fruits, leaf is one of the most important process in fruits production, while this process is typically performed manually in most countries. Computer vision techniques have applied for evaluating food quality as well as fruit grading. In this project different technique used that is image preprocessing, image segmentation k-means clustering algorithm to find out the infection present in image also calculate percentage of infection, from that percentage did the...

  6. Deep Neural Networks: A New Framework for Modeling Biological Vision and Brain Information Processing.

    Science.gov (United States)

    Kriegeskorte, Nikolaus

    2015-11-24

    Recent advances in neural network modeling have enabled major strides in computer vision and other artificial intelligence applications. Human-level visual recognition abilities are coming within reach of artificial systems. Artificial neural networks are inspired by the brain, and their computations could be implemented in biological neurons. Convolutional feedforward networks, which now dominate computer vision, take further inspiration from the architecture of the primate visual hierarchy. However, the current models are designed with engineering goals, not to model brain computations. Nevertheless, initial studies comparing internal representations between these models and primate brains find surprisingly similar representational spaces. With human-level performance no longer out of reach, we are entering an exciting new era, in which we will be able to build biologically faithful feedforward and recurrent computational models of how biological brains perform high-level feats of intelligence, including vision.

  7. Altered vision destabilizes gait in older persons.

    Science.gov (United States)

    Helbostad, Jorunn L; Vereijken, Beatrix; Hesseberg, Karin; Sletvold, Olav

    2009-08-01

    This study assessed the effects of dim light and four experimentally induced changes in vision on gait speed and footfall and trunk parameters in older persons walking on level ground. Using a quasi-experimental design, gait characteristics were assessed in full light, dim light, and in dim light combined with manipulations resulting in reduced depth vision, double vision, blurred vision, and tunnel vision, respectively. A convenience sample of 24 home-dwelling older women and men (mean age 78.5 years, SD 3.4) with normal vision for their age and able to walk at least 10 m without assistance participated. Outcome measures were gait speed and spatial and temporal parameters of footfall and trunk acceleration, derived from an electronic gait mat and accelerometers. Dim light alone had no effect. Vision manipulations combined with dim light had effect on most footfall parameters but few trunk parameters. The largest effects were found regarding double and tunnel vision. Men increased and women decreased gait speed following manipulations (p=0.017), with gender differences also in stride velocity variability (p=0.017) and inter-stride medio-lateral trunk acceleration variability (p=0.014). Gender effects were related to differences in body height and physical functioning. Results indicate that visual problems lead to a more cautious and unstable gait pattern even under relatively simple conditions. This points to the importance of assessing vision in older persons and correcting visual impairments where possible.

  8. Development of Vision Control Scheme of Extended Kalman filtering for Robot's Position Control

    International Nuclear Information System (INIS)

    Jang, W. S.; Kim, K. S.; Park, S. I.; Kim, K. Y.

    2003-01-01

    It is very important to reduce the computational time in estimating the parameters of vision control algorithm for robot's position control in real time. Unfortunately, the batch estimation commonly used requires too murk computational time because it is iteration method. So, the batch estimation has difficulty for robot's position control in real time. On the other hand, the Extended Kalman Filtering(EKF) has many advantages to calculate the parameters of vision system in that it is a simple and efficient recursive procedures. Thus, this study is to develop the EKF algorithm for the robot's vision control in real time. The vision system model used in this study involves six parameters to account for the inner(orientation, focal length etc) and outer (the relative location between robot and camera) parameters of camera. Then, EKF has been first applied to estimate these parameters, and then with these estimated parameters, also to estimate the robot's joint angles used for robot's operation. finally, the practicality of vision control scheme based on the EKF has been experimentally verified by performing the robot's position control

  9. Synthetic vision systems: operational considerations simulation experiment

    Science.gov (United States)

    Kramer, Lynda J.; Williams, Steven P.; Bailey, Randall E.; Glaab, Louis J.

    2007-04-01

    Synthetic vision is a computer-generated image of the external scene topography that is generated from aircraft attitude, high-precision navigation information, and data of the terrain, obstacles, cultural features, and other required flight information. A synthetic vision system (SVS) enhances this basic functionality with real-time integrity to ensure the validity of the databases, perform obstacle detection and independent navigation accuracy verification, and provide traffic surveillance. Over the last five years, NASA and its industry partners have developed and deployed SVS technologies for commercial, business, and general aviation aircraft which have been shown to provide significant improvements in terrain awareness and reductions in the potential for Controlled-Flight-Into-Terrain incidents / accidents compared to current generation cockpit technologies. It has been hypothesized that SVS displays can greatly improve the safety and operational flexibility of flight in Instrument Meteorological Conditions (IMC) to a level comparable to clear-day Visual Meteorological Conditions (VMC), regardless of actual weather conditions or time of day. An experiment was conducted to evaluate SVS and SVS-related technologies as well as the influence of where the information is provided to the pilot (e.g., on a Head-Up or Head-Down Display) for consideration in defining landing minima based upon aircraft and airport equipage. The "operational considerations" evaluated under this effort included reduced visibility, decision altitudes, and airport equipage requirements, such as approach lighting systems, for SVS-equipped aircraft. Subjective results from the present study suggest that synthetic vision imagery on both head-up and head-down displays may offer benefits in situation awareness; workload; and approach and landing performance in the visibility levels, approach lighting systems, and decision altitudes tested.

  10. Synthetic Vision Systems - Operational Considerations Simulation Experiment

    Science.gov (United States)

    Kramer, Lynda J.; Williams, Steven P.; Bailey, Randall E.; Glaab, Louis J.

    2007-01-01

    Synthetic vision is a computer-generated image of the external scene topography that is generated from aircraft attitude, high-precision navigation information, and data of the terrain, obstacles, cultural features, and other required flight information. A synthetic vision system (SVS) enhances this basic functionality with real-time integrity to ensure the validity of the databases, perform obstacle detection and independent navigation accuracy verification, and provide traffic surveillance. Over the last five years, NASA and its industry partners have developed and deployed SVS technologies for commercial, business, and general aviation aircraft which have been shown to provide significant improvements in terrain awareness and reductions in the potential for Controlled-Flight-Into-Terrain incidents/accidents compared to current generation cockpit technologies. It has been hypothesized that SVS displays can greatly improve the safety and operational flexibility of flight in Instrument Meteorological Conditions (IMC) to a level comparable to clear-day Visual Meteorological Conditions (VMC), regardless of actual weather conditions or time of day. An experiment was conducted to evaluate SVS and SVS-related technologies as well as the influence of where the information is provided to the pilot (e.g., on a Head-Up or Head-Down Display) for consideration in defining landing minima based upon aircraft and airport equipage. The "operational considerations" evaluated under this effort included reduced visibility, decision altitudes, and airport equipage requirements, such as approach lighting systems, for SVS-equipped aircraft. Subjective results from the present study suggest that synthetic vision imagery on both head-up and head-down displays may offer benefits in situation awareness; workload; and approach and landing performance in the visibility levels, approach lighting systems, and decision altitudes tested.

  11. Vision Restoration in Glaucoma by Activating Residual Vision with a Holistic, Clinical Approach: A Review.

    Science.gov (United States)

    Sabel, Bernhard A; Cárdenas-Morales, Lizbeth; Gao, Ying

    2018-01-01

    How to cite this article: Sabel BA, Cárdenas-Morales L, Gao Y. Vision Restoration in Glaucoma by activating Residual Vision with a Holistic, Clinical Approach: A Review. J Curr Glaucoma Pract 2018;12(1):1-9.

  12. Orientation and mobility training for adults with low vision.

    Science.gov (United States)

    Virgili, Gianni; Rubin, Gary

    2010-05-12

    little need for training and small room for further improvement (a ceiling effect), and the refinement of the curriculum allowing better tailoring to patients' specific needs and characteristics, in the second study. The review found two small quasi-randomised trials with similar methods, comparing training to physical exercise and assessing O&M physical performance by means of a volunteer or a professional, which were unable to demonstrate a difference. Therefore, there is little evidence on which type of O&M training is better for people with low vision who have specific characteristics and needs. Orientation and mobility instructors and scientists should plan randomised controlled trials (RCTs) to compare the effectiveness of different types of O&M training. A consensus is needed on the adoption of standard measurement instruments of mobility performance which are proven to be reliable and sensitive to the diverse mobility needs of people with low vision. For this purpose, questionnaires and performance-based tests may represent different tools that explore people with low vision's subjective experience or their objective functioning, respectively. In fact, it has to be observed that low vision rehabilitation research is increasingly shifting towards the use of quality of life questionnaires as an outcome measure, sometimes with the aim to study complex and multidisciplinary interventions including different types of education and support, of which O&M can be a component. An example of this is an ongoing cluster RCT conducted by Zijlstra et al. in The Netherlands. This trial is designed to compare standardised O&M training with usual O&M care not only for its effectiveness, but also its applicability and acceptability. This study adopts validated questionnaires for patients' subjective assessment of performance during activities of daily living. As performance assessment does not need to be made by an O&M trainer, this allows for masking of assessors and a patient

  13. Accuracy of vision technicians in screening ocular pathology at rural vision centres of southern India.

    Science.gov (United States)

    Suram, Vasantha; Addepalli, Uday Kumar; Krishnaiah, Sannapaneni; Kovai, Vilas; Khanna, Rohit C

    2016-03-01

    There is paucity of data on the inter-observer agreement and diagnostic accuracy between a primary-care technician (vision technician) and an ophthalmologist. Hence, the current study was conducted to assess the accuracy of vision technicians, to screen potentially sight-threatening ocular conditions at rural vision centres of southern India and their agreement with an ophthalmologist. In July to August 2010, patients presenting to seven vision centres in Adilabad district (Andhra Pradesh) were selected and screened in a masked manner by seven vision technicians followed by an examination by a consultant ophthalmologist. Agreement was assessed between vision technicians and the ophthalmologist for screening of potential sight-threatening ocular conditions and decisions for referral. The ophthalmologist's findings were considered as the reference standard. Two hundred and seventy-nine patients were enrolled at seven vision centres with a mean age of 32.9 ± 21.8 years. Agreement for screening of ocular pathology was 0.82 (95 per cent CI, 0.8-0.83). There was excellent agreement for cataract (0.97; 95 per cent CI, 0.93-1), refractive error (0.98; 95 per cent CI, 0.96-1), corneal pathology (1.0; 95 per cent CI, 1.0-1.0) and other anterior segment pathology (0.95; 95 per cent CI, 0.9-1); the agreement was moderate to fair for detection of glaucoma suspects (0.43; 95 per cent CI, 0.28-0.60) and retinal pathology (0.39; 95 per cent CI, 0.14-0.63). Sensitivity for screening of anterior segment pathology was 94.6-100 per cent. There was a fair to moderate sensitivity for glaucoma suspect; 35.6 per cent (95 per cent CI, 21.9-51.2) and retinal pathology 26.3 per cent (95 per cent CI, 9.2-51.2). Specificity for screening of ocular pathology was 98.2 to 100 per cent. The kappa (κ) agreement for referral for any pathology was 0.82 (0.8-0.83) CONCLUSION: As there is good agreement between the vision technicians and the ophthalmologist for screening and referral of

  14. Soft Computing Techniques in Vision Science

    CERN Document Server

    Yang, Yeon-Mo

    2012-01-01

    This Special Edited Volume is a unique approach towards Computational solution for the upcoming field of study called Vision Science. From a scientific firmament Optics, Ophthalmology, and Optical Science has surpassed an Odyssey of optimizing configurations of Optical systems, Surveillance Cameras and other Nano optical devices with the metaphor of Nano Science and Technology. Still these systems are falling short of its computational aspect to achieve the pinnacle of human vision system. In this edited volume much attention has been given to address the coupling issues Computational Science and Vision Studies.  It is a comprehensive collection of research works addressing various related areas of Vision Science like Visual Perception and Visual system, Cognitive Psychology, Neuroscience, Psychophysics and Ophthalmology, linguistic relativity, color vision etc. This issue carries some latest developments in the form of research articles and presentations. The volume is rich of contents with technical tools ...

  15. Dense image correspondences for computer vision

    CERN Document Server

    Liu, Ce

    2016-01-01

    This book describes the fundamental building-block of many new computer vision systems: dense and robust correspondence estimation. Dense correspondence estimation techniques are now successfully being used to solve a wide range of computer vision problems, very different from the traditional applications such techniques were originally developed to solve. This book introduces the techniques used for establishing correspondences between challenging image pairs, the novel features used to make these techniques robust, and the many problems dense correspondences are now being used to solve. The book provides information to anyone attempting to utilize dense correspondences in order to solve new or existing computer vision problems. The editors describe how to solve many computer vision problems by using dense correspondence estimation. Finally, it surveys resources, code, and data necessary for expediting the development of effective correspondence-based computer vision systems.   ·         Provides i...

  16. Performance of the Spot Vision Screener in Children Younger Than 3 Years of Age.

    Science.gov (United States)

    Forcina, Blake D; Peterseim, M Millicent; Wilson, M Edward; Cheeseman, Edward W; Feldman, Samuel; Marzolf, Amanda L; Wolf, Bethany J; Trivedi, Rupal H

    2017-06-01

    To evaluate the use of the Spot Vision Screener (Spot; Welch Allyn, Skaneateles Falls, New York, USA) for detection of amblyopia risk factors in children aged 6 months to 3 years, as defined by the 2013 guidelines of the American Association for Pediatric Ophthalmology and Strabismus. Reliability analysis. In this study, children seen from June 1, 2012, to April 30, 2016 were tested with the Spot during a routine visit. Enrolled children underwent a comprehensive eye examination including cycloplegic refraction and sensorimotor testing within 6 months of the testing date by a pediatric ophthalmologist masked to the Spot results. A total of 184 children were included. The Spot successfully obtained readings in 89.7% of patients. Compared with the ophthalmologist's examination, the Spot had an overall sensitivity of 89.8% and a specificity of 70.4%. The Spot achieved good sensitivity and specificity for detection of amblyopia risk factors in this young cohort, particularly in the older subgroup. Our data offer support for automated vision screening in young children. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Relationship of socioeconomic factors with vision-related quality of life on severe low vision and blind population in Indonesia

    Directory of Open Access Journals (Sweden)

    Habsyiyah Habsyiyah

    2015-12-01

    Full Text Available Background: Socioeconomic factors are known to be associated with visual impairment. Being someone who is visually impaired could affect his quality of life. The aim of this study is to evaluate the quality of life (QOL in severe low vision and blind population in Indonesia in relation to their socioeconomic status. Methods: A cross sectional population-based study was performed in 5 provinces, in Indonesia. Respondents of validation study on blindness data of national basic health survey 2013 (RISKESDAS 2013, who were above 18 years old with severe low vision (BCVA≥3/60 to 6/60 and blind (BCVA<3/60, were included in this study. Questionnaires for socioeconomic status and a questionnaire from the national eye institute visual function questionnaire 25 (NEI VFQ 25 for visual function were administered. Total  scores of NEI-VFQ25 were compared based on severity of visual impairment, educational level, occupation, literacy adequacy, income level, and residency. Data analysis was using independent T-test or Mann-Whitney test, and Chi square test.Results: A total of 134 subjects were enrolled in this study, most of them are  women (68.2%, aged >64 years old (64.9% with low education (65.7%, illiterate (52.2%, low income (71.6%, non working (63.4% and living in urban areas (58.2%. The blind population has lower VFQ scores than severe low vision (p=0.001. Different status of educational level, literacy adequacy, income level and residency did not show significant difference in VFQ scores, but those who have an occupation had better VFQ scores than those who do not (p=0.041.Conclusion: Visual related quality of life (VRQOL of severe low vision and blind population was associated significantly with occupational status. Because of culture and characteristics of Indonesian people, VRQOL of severe low vision and blind population in Indonesia was not affected by educational level, literacy, income level, and residency.

  18. Hepatic abscess versus peripheral cholangiocarcinoma: Sonographic differentiation

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hwan Hoon; Kim, Yun Hwan; Kang, Chang Ho; Chung, Kyoo Byung; Suh, Won Hyuck [Korea University College of Medicine, Seoul (Korea, Republic of); Lee, Chang Hee [Kunkuk University College of Medicine, Chung-Ju Hospital, Chung-Ju (Korea, Republic of)

    2000-12-15

    To find out the sonographic findings that are useful to differentiate hepatic abscess from peripheral cholangiocarcinoma. Twenty-two hepatic abscesses and 22 peripheral cholangiocarcinomas which had been confirmed histologically were included in this study. Objective points were echo characteristics of the lesion, internal septation, presence of peripheral low echoic rim, demarcation from normal liver(well or poorly defined), posterior enhancement, multiplicity, dilatation of bile duct(obstructive or non-obstructive), intrahepatic duct stone, pleural effusion, and intra-abdominal fluid collection. Echo characteristics of the lesion were classified in-to four types. Type I; Predominantly echogenic with hypoechoic portion, type II; Echogenic without hypoechoic portion, type III; Predominantly hypoechoic with echogenic portion, type IV; Hypoechoic without echogenic portion. 1)Nine abscesses and 2 peripheral cholangiocarcinomas were type I(p=0.037), 2)One abscess and 18 peripheral cholangiocarcinomas were type II(p=0.001), 3)Seven abscesses and none of peripheral cholangiocarcinomas were type III(p=0.001), 4)Five abscesses and 2 peripheral cholangiocarcinomas were type IV(p=0.410). Only 7 abscesses showed internal septations(p=0.013). One abscess and 9 peripheral cholangiocarcinomas showed peripheral hypoechoic halos(p=0.012). Only 9 peripheral cholangiocarcinomas showed obstructive bile duct dilatation (p=0.001). There were no statistically significant differences between abscess and peripheral cholangiocarcinoma on other objective points. Predominantly echogenic with hypoechoic portion, predominantly hypoechoic with echogenic portion, and internal septation are the features suggestive of hepatic abscess, and echogenic without hypoechoic portion, peripheral hypoechoic halo, obstructive bile duct dilatation are suggestive of peripheral cholangiocarcinoma. Therefore these sonographic findings are helpful to differentiate hepatic abscess from peripheral

  19. Participative Action Research: The Vision Conference

    Directory of Open Access Journals (Sweden)

    René Victor Valqui Vidal

    2003-11-01

    Full Text Available This paper presents the principles behind the design and management of the Vision Conference: a one-day workshop for a large group of participants endeavoured to create ideas, projects and visions for the future activities of a local community or an organisation. A case study from a local community in Denmark is also presented with the purpose of illustrating the organisation, planning and management of a Vision Conference. The paper focuses in the three central social processes of the conference: group work, problem solving and facilitation. The paper ends with a discussion of creativity and creativity techniques suitable for Vision Conferences.

  20. Regional new energy vision for Fukuoka city; Fukuokashi chiiki shin energy vision

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-02-01

    A regional new energy vision has been formulated for Fukuoka city, Fukuoka Prefecture, which will serve as a basic guide to the promotion of new energy introduction which is one of the measures for coping with environmental problems. The vision is described in five chapters of (1) the local characteristics of Fukuoka city, (2) energy situation in Fukuoka city, (3) basic program, (4) high priority plans, and (5) efforts to enhance the vision toward realization. Discussed as high priority plans are the introduction of new energy into public buildings above all others, high efficiency utilization of refuse-derived energy, utilization of new energy at water supply and drainage facilities, utilization of water temperature difference energy, introduction of clean energy vehicles, promotion of a new energy industry, and the extension of assistance for encouraging citizens and industrialists to adopt new energy. In extending assistance for encouraging the introduction of new energy, studies are made about measures for introducing new energy into individual residences and about a citizenry-involving new energy adopting industry (offering a site to the power generation industry) under the basal conditions that information be supplied sufficiently and that the citizenry and administration cooperate with each other in driving forward the vision. (NEDO)

  1. The Uniformity Illusion

    NARCIS (Netherlands)

    Otten, Marte; Pinto, Yair; Paffen, C.L.E.; Seth, Anil; Kanai, Ryota

    2017-01-01

    Vision in the fovea, the center of the visual field, is much more accurate and detailed than vision in the periphery. This is not in line with the rich phenomenology of peripheral vision. Here, we investigated a visual illusion that shows that detailed peripheral visual experience is partially based

  2. Eye Movement Training and Suggested Gaze Strategies in Tunnel Vision - A Randomized and Controlled Pilot Study.

    Directory of Open Access Journals (Sweden)

    Iliya V Ivanov

    Full Text Available Degenerative retinal diseases, especially retinitis pigmentosa (RP, lead to severe peripheral visual field loss (tunnel vision, which impairs mobility. The lack of peripheral information leads to fewer horizontal eye movements and, thus, diminished scanning in RP patients in a natural environment walking task. This randomized controlled study aimed to improve mobility and the dynamic visual field by applying a compensatory Exploratory Saccadic Training (EST.Oculomotor responses during walking and avoiding obstacles in a controlled environment were studied before and after saccade or reading training in 25 RP patients. Eye movements were recorded using a mobile infrared eye tracker (Tobii glasses that measured a range of spatial and temporal variables. Patients were randomly assigned to two training conditions: Saccade (experimental and reading (control training. All subjects who first performed reading training underwent experimental training later (waiting list control group. To assess the effect of training on subjects, we measured performance in the training task and the following outcome variables related to daily life: Response Time (RT during exploratory saccade training, Percent Preferred Walking Speed (PPWS, the number of collisions with obstacles, eye position variability, fixation duration, and the total number of fixations including the ones in the subjects' blind area of the visual field.In the saccade training group, RTs on average decreased, while the PPWS significantly increased. The improvement persisted, as tested 6 weeks after the end of the training. On average, the eye movement range of RP patients before and after training was similar to that of healthy observers. In both, the experimental and reading training groups, we found many fixations outside the subjects' seeing visual field before and after training. The average fixation duration was significantly shorter after the training, but only in the experimental training

  3. Eye Movement Training and Suggested Gaze Strategies in Tunnel Vision - A Randomized and Controlled Pilot Study.

    Science.gov (United States)

    Ivanov, Iliya V; Mackeben, Manfred; Vollmer, Annika; Martus, Peter; Nguyen, Nhung X; Trauzettel-Klosinski, Susanne

    2016-01-01

    Degenerative retinal diseases, especially retinitis pigmentosa (RP), lead to severe peripheral visual field loss (tunnel vision), which impairs mobility. The lack of peripheral information leads to fewer horizontal eye movements and, thus, diminished scanning in RP patients in a natural environment walking task. This randomized controlled study aimed to improve mobility and the dynamic visual field by applying a compensatory Exploratory Saccadic Training (EST). Oculomotor responses during walking and avoiding obstacles in a controlled environment were studied before and after saccade or reading training in 25 RP patients. Eye movements were recorded using a mobile infrared eye tracker (Tobii glasses) that measured a range of spatial and temporal variables. Patients were randomly assigned to two training conditions: Saccade (experimental) and reading (control) training. All subjects who first performed reading training underwent experimental training later (waiting list control group). To assess the effect of training on subjects, we measured performance in the training task and the following outcome variables related to daily life: Response Time (RT) during exploratory saccade training, Percent Preferred Walking Speed (PPWS), the number of collisions with obstacles, eye position variability, fixation duration, and the total number of fixations including the ones in the subjects' blind area of the visual field. In the saccade training group, RTs on average decreased, while the PPWS significantly increased. The improvement persisted, as tested 6 weeks after the end of the training. On average, the eye movement range of RP patients before and after training was similar to that of healthy observers. In both, the experimental and reading training groups, we found many fixations outside the subjects' seeing visual field before and after training. The average fixation duration was significantly shorter after the training, but only in the experimental training condition

  4. A wearable mobility device for the blind using retina-inspired dynamic vision sensors.

    Science.gov (United States)

    Ghaderi, Viviane S; Mulas, Marcello; Pereira, Vinicius Felisberto Santos; Everding, Lukas; Weikersdorfer, David; Conradt, Jorg

    2015-01-01

    Proposed is a prototype of a wearable mobility device which aims to assist the blind with navigation and object avoidance via auditory-vision-substitution. The described system uses two dynamic vision sensors and event-based information processing techniques to extract depth information. The 3D visual input is then processed using three different strategies, and converted to a 3D output sound using an individualized head-related transfer function. The performance of the device with different processing strategies is evaluated via initial tests with ten subjects. The outcome of these tests demonstrate promising performance of the system after only very short training times of a few minutes due to the minimal encoding of outputs from the vision sensors which are translated into simple sound patterns easily interpretable for the user. The envisioned system will allow for efficient real-time algorithms on a hands-free and lightweight device with exceptional battery life-time.

  5. Computer vision system in real-time for color determination on flat surface food

    Directory of Open Access Journals (Sweden)

    Erick Saldaña

    2013-03-01

    Full Text Available Artificial vision systems also known as computer vision are potent quality inspection tools, which can be applied in pattern recognition for fruits and vegetables analysis. The aim of this research was to design, implement and calibrate a new computer vision system (CVS in real-time for the color measurement on flat surface food. For this purpose was designed and implemented a device capable of performing this task (software and hardware, which consisted of two phases: a image acquisition and b image processing and analysis. Both the algorithm and the graphical interface (GUI were developed in Matlab. The CVS calibration was performed using a conventional colorimeter (Model CIEL* a* b*, where were estimated the errors of the color parameters: eL* = 5.001%, and ea* = 2.287%, and eb* = 4.314 % which ensure adequate and efficient automation application in industrial processes in the quality control in the food industry sector.

  6. Computer vision system in real-time for color determination on flat surface food

    Directory of Open Access Journals (Sweden)

    Erick Saldaña

    2013-01-01

    Full Text Available Artificial vision systems also known as computer vision are potent quality inspection tools, which can be applied in pattern recognition for fruits and vegetables analysis. The aim of this research was to design, implement and calibrate a new computer vision system (CVS in real - time f or the color measurement on flat surface food. For this purpose was designed and implemented a device capable of performing this task (software and hardware, which consisted of two phases: a image acquisition and b image processing and analysis. Both th e algorithm and the graphical interface (GUI were developed in Matlab. The CVS calibration was performed using a conventional colorimeter (Model CIEL* a* b*, where were estimated the errors of the color parameters: e L* = 5.001%, and e a* = 2.287%, and e b* = 4.314 % which ensure adequate and efficient automation application in industrial processes in the quality control in the food industry sector.

  7. Prevalence and predictors of peripheral neuropathy in nondiabetic children with chronic kidney disease.

    Science.gov (United States)

    Yoganathan, Sangeetha; Bagga, Arvind; Gulati, Sheffali; Toteja, G S; Hari, Pankaj; Sinha, Aditi; Pandey, Ravindra Mohan; Irshad, Mohammad

    2018-05-01

    This study sought to determine the prevalence and predictors of peripheral neuropathy in nondiabetic children with chronic kidney disease (CKD). Fifty-one consecutive normally nourished children, 3-18 years of age, with CKD stages IV and V of nondiabetic etiology were enrolled from May to December 2012. Nerve conduction studies were performed in 50 children. Blood samples were analyzed for the biochemical parameters, trace elements, and micronutrients. The prevalence of peripheral neuropathy in our cohort was 52% (95% confidence interval 37.65, 66.34). The majority (80.8%) of the children had axonal neuropathy, and 11.5% had demyelinating neuropathy. Isolated motor neuropathy was identified in 92.3% of the children, and sensorimotor neuropathy was identified in 7.6%. The significant risk factors associated with peripheral neuropathy were older age, low serum copper, and dialysis therapy. Electrodiagnostic studies should be performed in children with CKD to assess for peripheral neuropathy for the purpose of optimizing medical care. Muscle Nerve 57: 792-798, 2018. © 2017 Wiley Periodicals, Inc.

  8. Assessment of peripheral skeletal muscle microperfusion in a porcine model of peripheral arterial stenosis by steady-state contrast-enhanced ultrasound and Doppler flow measurement.

    Science.gov (United States)

    Naehle, Claas P; Steinberg, Verena A; Schild, Hans; Mommertz, Gottfried

    2015-05-01

    Noninvasive measurement of peripheral muscle microperfusion could potentially improve diagnosis, management, and treatment of peripheral arterial disease (PAD) and thus improve patient care. Contrast-enhanced ultrasound (CEUS) as a noninvasive diagnostic tool allows quantification of muscle perfusion. Increasing data on bolus technique CEUS reflecting microperfusion are becoming available, but only limited data on steady-state CEUS for assessment of muscle microperfusion are available. Therefore, the aim of this study was to evaluate steady-state CEUS for assessment of peripheral muscle microperfusion in a PAD animal model. In a porcine animal model, peripheral muscle microperfusion was quantified by steady-state CEUS replenishment kinetics (mean transit time [mTT] and wash-in rate [WiR]) of the biceps femoris muscle during intravenous steady-state infusion of INN-sulfur hexafluoride (SonoVue; Bracco, Geneva, Switzerland). In addition, macroperfusion was quantified at the external femoral artery with a Doppler flow probe. Peripheral muscle microperfusion and Doppler flow measurements were performed bilaterally at rest and under adenosine stress (70 μg/kg body weight) before and after unilateral creation of a moderate external iliac artery stenosis. All measurements could be performed completely in 10 pigs. Compared with baseline measurements, peripheral muscle microperfusion decreased significantly during adenosine stress (rest vs adenosine stress: mTT, 7.8 ± 3.3 vs 21.2 ± 17.8 s, P = .0006; WiR, 58.4 ± 38.1 vs 25.3 ± 15.6 arbitrary units [a.u.]/s, P flow, 122.3 ± 31.4 vs 83.6 ± 28.1 mL/min, P = .0067) and after stenosis creation (no stenosis vs stenosis: mTT, 8.1 ± 3.1 vs 29.2 ± 18.0 s, P = .0469; WiR, 53.0 ± 22.7 vs 13.6 ± 8.4 a.u./s, P = .0156; Doppler flow, 124.2 ± 41.8 vs 65.9 ± 40.0 mL/min, P = .0313). After stenosis creation, adenosine stress led to a further significant decrease of peripheral muscle microperfusion but had no effect on

  9. Peripheral Hole Acceptor Moieties on an Organic Dye Improve Dye‐Sensitized Solar Cell Performance

    Science.gov (United States)

    Hao, Yan; Gabrielsson, Erik; Lohse, Peter William; Yang, Wenxing; Johansson, Erik M. J.; Hagfeldt, Anders

    2015-01-01

    Investigation of charge transfer dynamics in dye‐sensitized solar cells is of fundamental interest and the control of these dynamics is a key factor for developing more efficient solar cell devices. One possibility for attenuating losses through recombination between injected electrons and oxidized dye molecules is to move the positive charge further away from the metal oxide surface. For this purpose, a metal‐free dye named E6 is developed, in which the chromophore core is tethered to two external triphenylamine (TPA) units. After photoinduced electron injection into TiO2, the remaining hole is rapidly transferred to a peripheral TPA unit. Electron–hole recombination is slowed down by 30% compared to a reference dye without peripheral TPA units. Furthermore, it is found that the added TPA moieties improve the electron blocking effect of the dye, retarding recombination of electrons from TiO2 to the cobalt‐based electrolyte. PMID:27722076

  10. Live Entertainment in a Fairytale Art-Peripheral Tourist Setting

    Directory of Open Access Journals (Sweden)

    Laila EL-Mahgary

    2016-05-01

    Full Text Available This article introduces a multidisciplinary study in which the different fields of musicology, social sciences and children’s ‘fairytale’ literature blend together. The interest in this topic came from a lack of attention in past studies on the art-peripheral performers’ and audiences’ experiences with the more popular form of entertainment in art-peripheral tourist settings. Another fundamental purpose for this research is to explore the important role of the art-peripheral ‘fairytale’ settings in transforming the different groups of hosts’ and guests’ everyday rational characters and performances, as they transgress from their cultural norms, and move through the liminal spaces of the sea. Consequently, new identities in Hurghada’s hotels’ fairytale scenes are being formed, and which are the outcome of localized and western, cultural, political, economic, and social constructions. The empirical method in this study puts emphasis on the texts of classical fairytale stories, which are used as an architextual model developed in the course of earlier research undertaken by the author. It is also well worth mentioning, that Hurghada’s art-peripheral hotel settings generate cultural tourism from the simple consumption of entertainment and popular music.

  11. VISION User Guide - VISION (Verifiable Fuel Cycle Simulation) Model

    International Nuclear Information System (INIS)

    Jacobson, Jacob J.; Jeffers, Robert F.; Matthern, Gretchen E.; Piet, Steven J.; Baker, Benjamin A.; Grimm, Joseph

    2009-01-01

    The purpose of this document is to provide a guide for using the current version of the Verifiable Fuel Cycle Simulation (VISION) model. This is a complex model with many parameters; the user is strongly encouraged to read this user guide before attempting to run the model. This model is an R and D work in progress and may contain errors and omissions. It is based upon numerous assumptions. This model is intended to assist in evaluating 'what if' scenarios and in comparing fuel, reactor, and fuel processing alternatives at a systems level for U.S. nuclear power. The model is not intended as a tool for process flow and design modeling of specific facilities nor for tracking individual units of fuel or other material through the system. The model is intended to examine the interactions among the components of a fuel system as a function of time varying system parameters; this model represents a dynamic rather than steady-state approximation of the nuclear fuel system. VISION models the nuclear cycle at the system level, not individual facilities, e.g., 'reactor types' not individual reactors and 'separation types' not individual separation plants. Natural uranium can be enriched, which produces enriched uranium, which goes into fuel fabrication, and depleted uranium (DU), which goes into storage. Fuel is transformed (transmuted) in reactors and then goes into a storage buffer. Used fuel can be pulled from storage into either separation of disposal. If sent to separations, fuel is transformed (partitioned) into fuel products, recovered uranium, and various categories of waste. Recycled material is stored until used by its assigned reactor type. Note that recovered uranium is itself often partitioned: some RU flows with recycled transuranic elements, some flows with wastes, and the rest is designated RU. RU comes out of storage if needed to correct the U/TRU ratio in new recycled fuel. Neither RU nor DU are designated as wastes. VISION is comprised of several Microsoft

  12. delta-vision

    Data.gov (United States)

    California Natural Resource Agency — Delta Vision is intended to identify a strategy for managing the Sacramento-San Joaquin Delta as a sustainable ecosystem that would continue to support environmental...

  13. Computer and machine vision theory, algorithms, practicalities

    CERN Document Server

    Davies, E R

    2012-01-01

    Computer and Machine Vision: Theory, Algorithms, Practicalities (previously entitled Machine Vision) clearly and systematically presents the basic methodology of computer and machine vision, covering the essential elements of the theory while emphasizing algorithmic and practical design constraints. This fully revised fourth edition has brought in more of the concepts and applications of computer vision, making it a very comprehensive and up-to-date tutorial text suitable for graduate students, researchers and R&D engineers working in this vibrant subject. Key features include: Practical examples and case studies give the 'ins and outs' of developing real-world vision systems, giving engineers the realities of implementing the principles in practice New chapters containing case studies on surveillance and driver assistance systems give practical methods on these cutting-edge applications in computer vision Necessary mathematics and essential theory are made approachable by careful explanations and well-il...

  14. Standards for vision science libraries: 2014 revision.

    Science.gov (United States)

    Motte, Kristin; Caldwell, C Brooke; Lamson, Karen S; Ferimer, Suzanne; Nims, J Chris

    2014-10-01

    This Association of Vision Science Librarians revision of the "Standards for Vision Science Libraries" aspires to provide benchmarks to address the needs for the services and resources of modern vision science libraries (academic, medical or hospital, pharmaceutical, and so on), which share a core mission, are varied by type, and are located throughout the world. Through multiple meeting discussions, member surveys, and a collaborative revision process, the standards have been updated for the first time in over a decade. While the range of types of libraries supporting vision science services, education, and research is wide, all libraries, regardless of type, share core attributes, which the standards address. The current standards can and should be used to help develop new vision science libraries or to expand the growth of existing libraries, as well as to support vision science librarians in their work to better provide services and resources to their respective users.

  15. 77 FR 7657 - Qualification of Drivers; Exemption Applications; Vision

    Science.gov (United States)

    2012-02-13

    ... submit comments bearing the Federal Docket Management System (FDMS) Docket No. FMCSA-2011-0324 using any... on-line instructions for submitting comments. Mail: Docket Management Facility; U.S. Department of... 2011, his optometrist noted, ``It is my clinical impression that he has sufficient vision to perform...

  16. Efficacy of vision therapy in children with learning disability and associated binocular vision anomalies

    Directory of Open Access Journals (Sweden)

    Jameel Rizwana Hussaindeen

    2018-01-01

    Conclusion: Children with specific learning disorders have a high frequency of binocular vision disorders and vision therapy plays a significant role in improving the BV parameters. Children with SLD should be screened for BV anomalies as it could potentially be an added hindrance to the reading difficulty in this special population.

  17. Energy saving vision in Miyazu City region (FY2000); Miyazushi chiiki sho energy vision (2000 nendo)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    An energy-saving vision was decided on in Miyazu City, Kyoto Prefecture, with its outline reported. The city promulgated the 'Miyazu City plan for the prevention of global warming' earlier this year, aiming at reduction in carbon dioxide exhaust by 25% in ten years ending 2010, and accordingly, also formulated the energy-saving vision on the basis of the plan. The measures with the citizens' life in mind were, for example, encouragement to participate in energy-saving monitor activity, publication of data of survey result, implementation of 'Miyazu eco-life school', support for citizens' voluntary action, utilization of public information/home pages, renewal of equipment and facilities, and preparation of performance/price data for new housing construction and so on. In addition, survey on actual condition, examination for improvements, etc., were among the measures intended for such sectors as hotels/inns, public transportation, manufacturing, and construction, and for the City administration itself. Furthermore, as measures to collaborate with energy suppliers, building an information exchange system is under consideration. (NEDO)

  18. Prevalence of computer vision syndrome in Erbil

    Directory of Open Access Journals (Sweden)

    Dler Jalal Ahmed

    2018-04-01

    Full Text Available Background and objective: Nearly all colleges, universities and homes today are regularly using video display terminals, such as computer, iPad, mobile, and TV. Very little research has been carried out on Kurdish users to reveal the effect of video display terminals on the eye and vision. This study aimed to evaluate the prevalence of computer vision syndrome among computer users. Methods: A hospital based cross-sectional study was conducted in the Ophthalmology Department of Rizgary and Erbil teaching hospitals in Erbil city. Those used computers in the months preceding the date of this study were included in the study. Results: Among 173 participants aged between 8 to 48 years (mean age of 23.28±6.6 years, the prevalence of computer vision syndrome found to be 89.65%. The most disturbing symptom was eye irritation (79.8%, followed by blurred vision(75.7%. Participants who were using visual display terminals for more than six hours per day were at higher risk of developing nearly all symptoms of computer vision syndrome. Significant correlation was found between time-consuming on computer and symptoms such as headache (P <0.001, redness (P <0.001, eye irritation (P <0.001, blurred vision (P <0.001 and neck pain (P <0.001. Conclusion: The present study demonstrates that more than three-fourths of the participants had one of the symptoms of computer vision syndrome while working on visual display terminals. Keywords: Computer vision syndrome; Headache; Neck pain; Blurred vision.

  19. Representing vision and blindness.

    Science.gov (United States)

    Ray, Patrick L; Cox, Alexander P; Jensen, Mark; Allen, Travis; Duncan, William; Diehl, Alexander D

    2016-01-01

    There have been relatively few attempts to represent vision or blindness ontologically. This is unsurprising as the related phenomena of sight and blindness are difficult to represent ontologically for a variety of reasons. Blindness has escaped ontological capture at least in part because: blindness or the employment of the term 'blindness' seems to vary from context to context, blindness can present in a myriad of types and degrees, and there is no precedent for representing complex phenomena such as blindness. We explore current attempts to represent vision or blindness, and show how these attempts fail at representing subtypes of blindness (viz., color blindness, flash blindness, and inattentional blindness). We examine the results found through a review of current attempts and identify where they have failed. By analyzing our test cases of different types of blindness along with the strengths and weaknesses of previous attempts, we have identified the general features of blindness and vision. We propose an ontological solution to represent vision and blindness, which capitalizes on resources afforded to one who utilizes the Basic Formal Ontology as an upper-level ontology. The solution we propose here involves specifying the trigger conditions of a disposition as well as the processes that realize that disposition. Once these are specified we can characterize vision as a function that is realized by certain (in this case) biological processes under a range of triggering conditions. When the range of conditions under which the processes can be realized are reduced beyond a certain threshold, we are able to say that blindness is present. We characterize vision as a function that is realized as a seeing process and blindness as a reduction in the conditions under which the sight function is realized. This solution is desirable because it leverages current features of a major upper-level ontology, accurately captures the phenomenon of blindness, and can be

  20. An inkjet vision measurement technique for high-frequency jetting

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Kye-Si, E-mail: kskwon@sch.ac.kr; Jang, Min-Hyuck; Park, Ha Yeong [Department of Mechanical Engineering, Soonchunhyang University 22, Soonchunhyang-Ro, Shinchang, Asan Chungnam 336-745 (Korea, Republic of); Ko, Hyun-Seok [Department of Electrical and Robot Engineering, Soonchunhyang University, 22, Soonchunhyang-Ro, Shinchang, Asan Chungnam 336-745 (Korea, Republic of)

    2014-06-15

    Inkjet technology has been used as manufacturing a tool for printed electronics. To increase the productivity, the jetting frequency needs to be increased. When using high-frequency jetting, the printed pattern quality could be non-uniform since the jetting performance characteristics including the jetting speed and droplet volume could vary significantly with increases in jet frequency. Therefore, high-frequency jetting behavior must be evaluated properly for improvement. However, it is difficult to measure high-frequency jetting behavior using previous vision analysis methods, because subsequent droplets are close or even merged. In this paper, we present vision measurement techniques to evaluate the drop formation of high-frequency jetting. The proposed method is based on tracking target droplets such that subsequent droplets can be excluded in the image analysis by focusing on the target droplet. Finally, a frequency sweeping method for jetting speed and droplet volume is presented to understand the overall jetting frequency effects on jetting performance.

  1. An inkjet vision measurement technique for high-frequency jetting

    International Nuclear Information System (INIS)

    Kwon, Kye-Si; Jang, Min-Hyuck; Park, Ha Yeong; Ko, Hyun-Seok

    2014-01-01

    Inkjet technology has been used as manufacturing a tool for printed electronics. To increase the productivity, the jetting frequency needs to be increased. When using high-frequency jetting, the printed pattern quality could be non-uniform since the jetting performance characteristics including the jetting speed and droplet volume could vary significantly with increases in jet frequency. Therefore, high-frequency jetting behavior must be evaluated properly for improvement. However, it is difficult to measure high-frequency jetting behavior using previous vision analysis methods, because subsequent droplets are close or even merged. In this paper, we present vision measurement techniques to evaluate the drop formation of high-frequency jetting. The proposed method is based on tracking target droplets such that subsequent droplets can be excluded in the image analysis by focusing on the target droplet. Finally, a frequency sweeping method for jetting speed and droplet volume is presented to understand the overall jetting frequency effects on jetting performance

  2. EVALUATION OF SIFT AND SURF FOR VISION BASED LOCALIZATION

    Directory of Open Access Journals (Sweden)

    X. Qu

    2016-06-01

    Full Text Available Vision based localization is widely investigated for the autonomous navigation and robotics. One of the basic steps of vision based localization is the extraction of interest points in images that are captured by the embedded camera. In this paper, SIFT and SURF extractors were chosen to evaluate their performance in localization. Four street view image sequences captured by a mobile mapping system, were used for the evaluation and both SIFT and SURF were tested on different image scales. Besides, the impact of the interest point distribution was also studied. We evaluated the performances from for aspects: repeatability, precision, accuracy and runtime. The local bundle adjustment method was applied to refine the pose parameters and the 3D coordinates of tie points. According to the results of our experiments, SIFT was more reliable than SURF. Apart from this, both the accuracy and the efficiency of localization can be improved if the distribution of feature points are well constrained for SIFT.

  3. Hi-Vision telecine system using pickup tube

    Science.gov (United States)

    Iijima, Goro

    1992-08-01

    Hi-Vision broadcasting, offering far more lifelike pictures than those produced by existing television broadcasting systems, has enormous potential in both industrial and commercial fields. The dissemination of the Hi-Vision system will enable vivid, movie theater quality pictures to be readily enjoyed in homes in the near future. To convert motion film pictures into Hi-Vision signals, a telecine system is needed. The Hi-Vision telecine systems currently under development are the "laser telecine," "flying-spot telecine," and "Saticon telecine" systems. This paper provides an overview of the pickup tube type Hi-Vision telecine system (referred to herein as the Saticon telecine system) developed and marketed by Ikegami Tsushinki Co., Ltd.

  4. Machine-Vision Systems Selection for Agricultural Vehicles: A Guide

    Directory of Open Access Journals (Sweden)

    Gonzalo Pajares

    2016-11-01

    Full Text Available Machine vision systems are becoming increasingly common onboard agricultural vehicles (autonomous and non-autonomous for different tasks. This paper provides guidelines for selecting machine-vision systems for optimum performance, considering the adverse conditions on these outdoor environments with high variability on the illumination, irregular terrain conditions or different plant growth states, among others. In this regard, three main topics have been conveniently addressed for the best selection: (a spectral bands (visible and infrared; (b imaging sensors and optical systems (including intrinsic parameters and (c geometric visual system arrangement (considering extrinsic parameters and stereovision systems. A general overview, with detailed description and technical support, is provided for each topic with illustrative examples focused on specific applications in agriculture, although they could be applied in different contexts other than agricultural. A case study is provided as a result of research in the RHEA (Robot Fleets for Highly Effective Agriculture and Forestry Management project for effective weed control in maize fields (wide-rows crops, funded by the European Union, where the machine vision system onboard the autonomous vehicles was the most important part of the full perception system, where machine vision was the most relevant. Details and results about crop row detection, weed patches identification, autonomous vehicle guidance and obstacle detection are provided together with a review of methods and approaches on these topics.

  5. Low Vision Care: The Need to Maximise Visual Potential

    Directory of Open Access Journals (Sweden)

    Ramachandra Pararajasegaram

    2004-01-01

    Full Text Available People with low vision have residual vision with some light perception, but their vision loss does not lend itself to improvement by standard spectacles or medical or surgical treatment. Such persons have the potential for enhanced functional vision if they receive appropriate low vision care services.

  6. Automatic micropart assembly of 3-Dimensional structure by vision based control

    International Nuclear Information System (INIS)

    Wang, Lidai; Kim, Seung Min

    2008-01-01

    We propose a vision control strategy to perform automatic microassembly tasks in three-dimension (3-D) and develop relevant control software: specifically, using a 6 degree-of-freedom (DOF) robotic workstation to control a passive microgripper to automatically grasp a designated micropart from the chip, pivot the micropart, and then move the micropart to be vertically inserted into a designated slot on the chip. In the proposed control strategy, the whole microassembly task is divided into two subtasks, micro-grasping and micro-joining, in sequence. To guarantee the success of microassembly and manipulation accuracy, two different two-stage feedback motion strategies, the pattern matching and auto-focus method are employed, with the use of vision-based control system and the vision control software developed. Experiments conducted demonstrate the efficiency and validity of the proposed control strategy

  7. Automatic micropart assembly of 3-Dimensional structure by vision based control

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Lidai [University of Toronto, Toronto (Canada); Kim, Seung Min [Korean Intellectual Property Office, Daejeon (Korea, Republic of)

    2008-12-15

    We propose a vision control strategy to perform automatic microassembly tasks in three-dimension (3-D) and develop relevant control software: specifically, using a 6 degree-of-freedom (DOF) robotic workstation to control a passive microgripper to automatically grasp a designated micropart from the chip, pivot the micropart, and then move the micropart to be vertically inserted into a designated slot on the chip. In the proposed control strategy, the whole microassembly task is divided into two subtasks, micro-grasping and micro-joining, in sequence. To guarantee the success of microassembly and manipulation accuracy, two different two-stage feedback motion strategies, the pattern matching and auto-focus method are employed, with the use of vision-based control system and the vision control software developed. Experiments conducted demonstrate the efficiency and validity of the proposed control strategy

  8. A robust embedded vision system feasible white balance algorithm

    Science.gov (United States)

    Wang, Yuan; Yu, Feihong

    2018-01-01

    White balance is a very important part of the color image processing pipeline. In order to meet the need of efficiency and accuracy in embedded machine vision processing system, an efficient and robust white balance algorithm combining several classical ones is proposed. The proposed algorithm mainly has three parts. Firstly, in order to guarantee higher efficiency, an initial parameter calculated from the statistics of R, G and B components from raw data is used to initialize the following iterative method. After that, the bilinear interpolation algorithm is utilized to implement demosaicing procedure. Finally, an adaptive step adjustable scheme is introduced to ensure the controllability and robustness of the algorithm. In order to verify the proposed algorithm's performance on embedded vision system, a smart camera based on IMX6 DualLite, IMX291 and XC6130 is designed. Extensive experiments on a large amount of images under different color temperatures and exposure conditions illustrate that the proposed white balance algorithm avoids color deviation problem effectively, achieves a good balance between efficiency and quality, and is suitable for embedded machine vision processing system.

  9. Ultrasound Guidance as a Rescue Technique for Peripheral Intravenous Cannulation

    National Research Council Canada - National Science Library

    Pappas, Nancy L; Michaud, Terese E; Wolbers, Russell M; Steward, James C; Fevurly, Thomas A; Samolitis, Timothy J; Shoneboom, Bruce A; Watts, Dorraine D

    2006-01-01

    Peripheral intravenous (W) cannulation can be difficult to perform using the traditional landmark or visual/palpation technique in patients with access difficulties such as deep, sclerotic, small, or fragile veins...

  10. Algorithmic strategies for FPGA-based vision

    OpenAIRE

    Lim, Yoong Kang

    2016-01-01

    As demands for real-time computer vision applications increase, implementations on alternative architectures have been explored. These architectures include Field-Programmable Gate Arrays (FPGAs), which offer a high degree of flexibility and parallelism. A problem with this is that many computer vision algorithms have been optimized for serial processing, and this often does not map well to FPGA implementation. This thesis introduces the concept of FPGA-tailored computer vision algorithms...

  11. Eldercare at Home: Vision Problems

    Science.gov (United States)

    ... seeing close objects or reading small print. Many things can be done to help with these vision problems. Using reading ... t Working If vision problems seem to be getting worse and are of major concern to the ... what the results have been. Related Resources ...

  12. Machine learning, computer vision, and probabilistic models in jet physics

    CERN Multimedia

    CERN. Geneva; NACHMAN, Ben

    2015-01-01

    In this talk we present recent developments in the application of machine learning, computer vision, and probabilistic models to the analysis and interpretation of LHC events. First, we will introduce the concept of jet-images and computer vision techniques for jet tagging. Jet images enabled the connection between jet substructure and tagging with the fields of computer vision and image processing for the first time, improving the performance to identify highly boosted W bosons with respect to state-of-the-art methods, and providing a new way to visualize the discriminant features of different classes of jets, adding a new capability to understand the physics within jets and to design more powerful jet tagging methods. Second, we will present Fuzzy jets: a new paradigm for jet clustering using machine learning methods. Fuzzy jets view jet clustering as an unsupervised learning task and incorporate a probabilistic assignment of particles to jets to learn new features of the jet structure. In particular, we wi...

  13. Embedded active vision system based on an FPGA architecture

    OpenAIRE

    Chalimbaud , Pierre; Berry , François

    2006-01-01

    International audience; In computer vision and more particularly in vision processing, the impressive evolution of algorithms and the emergence of new techniques dramatically increase algorithm complexity. In this paper, a novel FPGA-based architecture dedicated to active vision (and more precisely early vision) is proposed. Active vision appears as an alternative approach to deal with artificial vision problems. The central idea is to take into account the perceptual aspects of visual tasks,...

  14. Is laparoscopic appendicectomy a safe procedure for trainees in the peripheral hospital setting?

    LENUS (Irish Health Repository)

    Emmanuel, A

    2011-10-01

    Laparoscopic appendicectomy has become standard in the treatment of acute appendicitis in most hospitals in Ireland. Studies have shown that it is a safe procedure for trainees to perform. However, these studies were conducted in university teaching hospitals whereas a significant proportion of training in Ireland takes place in peripheral hospitals which provide a different training environment. The aim of this study was to determine whether laparoscopic appendicectomy is a safe procedure for surgical trainees to perform in a peripheral hospital setting. A retrospective analysis was performed of appendicectomies carried out at a peripheral hospital over a 12 month period. Comparisons were made between consultant surgeons and trainees for a variety of outcomes. Of 155 appendicectomies, 129 (83.2%) were performed laparoscopically, of which 10 (7.75%) were converted to open. Consultants performed 99 (77%) laparoscopic appendicectomies. There were no statistically significant differences between consultants and trainees in complication rates (19 (19.2%) vs. 4 (13.3%), p = 0.46), mean length of hospital stay (4.7 +\\/- 4.0 vs. 3.4 +\\/- 3.3 days, p = 0.13), or rate of conversion to open operation (9 (9.1%) vs. 1 (3.3%), p = 0.45). For cases of complicated appendicitis there were no significant differences between consultants and trainees in complication rates (12 vs. 2, p = 0.40) or length of hospital stay (6.4 +\\/- 3.9 vs. 4.7 +\\/- 5.6 days, p = 0.27). We conclude that laparoscopic appendicectomy is a safe procedure for trainees to perform in the peripheral hospital setting and should be incorporated into surgical training programs at an early stage of training.

  15. Age-Related Psychophysical Changes and Low Vision

    Science.gov (United States)

    Dagnelie, Gislin

    2013-01-01

    When considering the burden of visual impairment on aging individuals and society at large, it is important to bear in mind that vision changes are a natural aspect of aging. In this article, we consider vision changes that are part of normal aging, the prevalence of abnormal vision changes caused by disorders of the visual system, and the anticipated incidence and impact of visual impairment as the US population ages. We then discuss the services available to reduce the impact of vision loss, and the extent to which those services can and should be improved, not only to be better prepared for the anticipated increase in low vision over the coming decades, but also to increase the awareness of interactions between visual impairment and comorbidities that are common among the elderly. Finally, we consider how to promote improved quality, availability, and acceptance of low vision care to lessen the impact of visual impairment on individuals, and its burden on society. PMID:24335074

  16. State of Vision Development in Slovenian Companies

    Directory of Open Access Journals (Sweden)

    Vojko Toman

    2014-05-01

    Full Text Available Vision is a prerequisite for efficient strategic planning and the effectiveness of a company. If a company has no vision (i.e., it does not know where it is heading, then it cannot build on advantages, eliminate weaknesses, exploit opportunities and avoid threats. The term ‘vision’ is often used in scientific and professional literature, but it should be noted that different authors understand the term differently and often discuss it inadequately. Many questions regarding the nature of vision arise in practice and in theory, and I answer many of them in my article. I define vision, explain the reasons for its necessity and provide its characteristics and content. I define mission and explain the main difference between vision and mission. The majority of the article presents the results of empirical research on the state of vision setting in Slovenian companies. The article highlights the way in which these terms are understood by top managers.

  17. The Reliability of the CVI Range: A Functional Vision Assessment for Children with Cortical Visual Impairment

    Science.gov (United States)

    Newcomb, Sandra

    2010-01-01

    Children who are identified as visually impaired frequently have a functional vision assessment as one way to determine how their visual impairment affects their educational performance. The CVI Range is a functional vision assessment for children with cortical visual impairment. The purpose of the study presented here was to examine the…

  18. Understanding and applying machine vision

    CERN Document Server

    Zeuch, Nello

    2000-01-01

    A discussion of applications of machine vision technology in the semiconductor, electronic, automotive, wood, food, pharmaceutical, printing, and container industries. It describes systems that enable projects to move forward swiftly and efficiently, and focuses on the nuances of the engineering and system integration of machine vision technology.

  19. 77 FR 3547 - Qualification of Drivers; Exemption Applications; Vision

    Science.gov (United States)

    2012-01-24

    ... restricting him or her to driving in intrastate commerce. To evaluate the effect of these exemptions on safety... the vision deficiency for the past 3 years. Recent driving performance is especially important in evaluating future safety, according to several research studies designed to correlate past and future driving...

  20. 77 FR 38379 - Qualification of Drivers; Exemption Applications; Vision

    Science.gov (United States)

    2012-06-27

    ... restricting him or her to driving in intrastate commerce. To evaluate the effect of these exemptions on safety... the vision deficiency for the past 3 years. Recent driving performance is especially important in evaluating future safety, according to several research studies designed to correlate past and future driving...