WorldWideScience

Sample records for peripheral vision capabilities

  1. Beauty and cuteness in peripheral vision

    Science.gov (United States)

    Kuraguchi, Kana; Ashida, Hiroshi

    2015-01-01

    Guo et al. (2011) showed that attractiveness was detectable in peripheral vision. Since there are different types of attractiveness (Rhodes, 2006), we investigated how beauty and cuteness are detected in peripheral vision with a brief presentation. Participants (n = 45) observed two Japanese female faces for 100 ms, then were asked to respond which face was more beautiful (or cuter). The results indicated that both beauty and cuteness were detectable in peripheral vision, but not in the same manner. Discrimination rates for judging beauty were invariant in peripheral and central vision, while discrimination rates for judging cuteness declined in peripheral vision as compared with central vision. This was not explained by lower resolution in peripheral vision. In addition, for male participants, it was more difficult to judge cuteness than beauty in peripheral vision, thus suggesting that gender differences can have a certain effect when judging cuteness. Therefore, central vision might be suitable for judging cuteness while judging beauty might not be affected by either central or peripheral vision. This might be related with the functional difference between beauty and cuteness. PMID:25999883

  2. Mini-review: Far peripheral vision.

    Science.gov (United States)

    Simpson, Michael J

    2017-11-01

    The region of far peripheral vision, beyond 60 degrees of visual angle, is important to the evaluation of peripheral dark shadows (negative dysphotopsia) seen by some intraocular lens (IOL) patients. Theoretical calculations show that the limited diameter of an IOL affects ray paths at large angles, leading to a dimming of the main image for small pupils, and to peripheral illumination by light bypassing the IOL for larger pupils. These effects are rarely bothersome, and cataract surgery is highly successful, but there is a need to improve the characterization of far peripheral vision, for both pseudophakic and phakic eyes. Perimetry is the main quantitative test, but the purpose is to evaluate pathologies rather than characterize vision (and object and image regions are no longer uniquely related in the pseudophakic eye). The maximum visual angle is approximately 105 0 , but there is limited information about variations with age, race, or refractive error (in case there is an unexpected link with the development of myopia), or about how clear cornea, iris location, and the limiting retina are related. Also, the detection of peripheral motion is widely recognized to be important, yet rarely evaluated. Overall, people rarely complain specifically about this visual region, but with "normal" vision including an IOL for >5% of people, and increasing interest in virtual reality and augmented reality, there are new reasons to characterize peripheral vision more completely. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Coaching Peripheral Vision Training for Soccer Athletes

    Science.gov (United States)

    Marques, Nelson Kautzner, Jr.

    2010-01-01

    Brazilian Soccer began developing its current emphasis on peripheral vision in the late 1950s, by initiative of coach of the Canto do Rio Football Club, in Niteroi, Rio de Janeiro, a pioneer in the development of peripheral vision training in soccer players. Peripheral vision training gained world relevance when a young talent from Canto do Rio,…

  4. Peripheral vision of youths with low vision: motion perception, crowding, and visual search.

    Science.gov (United States)

    Tadin, Duje; Nyquist, Jeffrey B; Lusk, Kelly E; Corn, Anne L; Lappin, Joseph S

    2012-08-24

    Effects of low vision on peripheral visual function are poorly understood, especially in children whose visual skills are still developing. The aim of this study was to measure both central and peripheral visual functions in youths with typical and low vision. Of specific interest was the extent to which measures of foveal function predict performance of peripheral tasks. We assessed central and peripheral visual functions in youths with typical vision (n = 7, ages 10-17) and low vision (n = 24, ages 9-18). Experimental measures used both static and moving stimuli and included visual crowding, visual search, motion acuity, motion direction discrimination, and multitarget motion comparison. In most tasks, visual function was impaired in youths with low vision. Substantial differences, however, were found both between participant groups and, importantly, across different tasks within participant groups. Foveal visual acuity was a modest predictor of peripheral form vision and motion sensitivity in either the central or peripheral field. Despite exhibiting normal motion discriminations in fovea, motion sensitivity of youths with low vision deteriorated in the periphery. This contrasted with typically sighted participants, who showed improved motion sensitivity with increasing eccentricity. Visual search was greatly impaired in youths with low vision. Our results reveal a complex pattern of visual deficits in peripheral vision and indicate a significant role of attentional mechanisms in observed impairments. These deficits were not adequately captured by measures of foveal function, arguing for the importance of independently assessing peripheral visual function.

  5. Peripheral Vision of Youths with Low Vision: Motion Perception, Crowding, and Visual Search

    Science.gov (United States)

    Tadin, Duje; Nyquist, Jeffrey B.; Lusk, Kelly E.; Corn, Anne L.; Lappin, Joseph S.

    2012-01-01

    Purpose. Effects of low vision on peripheral visual function are poorly understood, especially in children whose visual skills are still developing. The aim of this study was to measure both central and peripheral visual functions in youths with typical and low vision. Of specific interest was the extent to which measures of foveal function predict performance of peripheral tasks. Methods. We assessed central and peripheral visual functions in youths with typical vision (n = 7, ages 10–17) and low vision (n = 24, ages 9–18). Experimental measures used both static and moving stimuli and included visual crowding, visual search, motion acuity, motion direction discrimination, and multitarget motion comparison. Results. In most tasks, visual function was impaired in youths with low vision. Substantial differences, however, were found both between participant groups and, importantly, across different tasks within participant groups. Foveal visual acuity was a modest predictor of peripheral form vision and motion sensitivity in either the central or peripheral field. Despite exhibiting normal motion discriminations in fovea, motion sensitivity of youths with low vision deteriorated in the periphery. This contrasted with typically sighted participants, who showed improved motion sensitivity with increasing eccentricity. Visual search was greatly impaired in youths with low vision. Conclusions. Our results reveal a complex pattern of visual deficits in peripheral vision and indicate a significant role of attentional mechanisms in observed impairments. These deficits were not adequately captured by measures of foveal function, arguing for the importance of independently assessing peripheral visual function. PMID:22836766

  6. Agnosic vision is like peripheral vision, which is limited by crowding.

    Science.gov (United States)

    Strappini, Francesca; Pelli, Denis G; Di Pace, Enrico; Martelli, Marialuisa

    2017-04-01

    Visual agnosia is a neuropsychological impairment of visual object recognition despite near-normal acuity and visual fields. A century of research has provided only a rudimentary account of the functional damage underlying this deficit. We find that the object-recognition ability of agnosic patients viewing an object directly is like that of normally-sighted observers viewing it indirectly, with peripheral vision. Thus, agnosic vision is like peripheral vision. We obtained 14 visual-object-recognition tests that are commonly used for diagnosis of visual agnosia. Our "standard" normal observer took these tests at various eccentricities in his periphery. Analyzing the published data of 32 apperceptive agnosia patients and a group of 14 posterior cortical atrophy (PCA) patients on these tests, we find that each patient's pattern of object recognition deficits is well characterized by one number, the equivalent eccentricity at which our standard observer's peripheral vision is like the central vision of the agnosic patient. In other words, each agnosic patient's equivalent eccentricity is conserved across tests. Across patients, equivalent eccentricity ranges from 4 to 40 deg, which rates severity of the visual deficit. In normal peripheral vision, the required size to perceive a simple image (e.g., an isolated letter) is limited by acuity, and that for a complex image (e.g., a face or a word) is limited by crowding. In crowding, adjacent simple objects appear unrecognizably jumbled unless their spacing exceeds the crowding distance, which grows linearly with eccentricity. Besides conservation of equivalent eccentricity across object-recognition tests, we also find conservation, from eccentricity to agnosia, of the relative susceptibility of recognition of ten visual tests. These findings show that agnosic vision is like eccentric vision. Whence crowding? Peripheral vision, strabismic amblyopia, and possibly apperceptive agnosia are all limited by crowding, making it

  7. Peripheral vision benefits spatial learning by guiding eye movements.

    Science.gov (United States)

    Yamamoto, Naohide; Philbeck, John W

    2013-01-01

    The loss of peripheral vision impairs spatial learning and navigation. However, the mechanisms underlying these impairments remain poorly understood. One advantage of having peripheral vision is that objects in an environment are easily detected and readily foveated via eye movements. The present study examined this potential benefit of peripheral vision by investigating whether competent performance in spatial learning requires effective eye movements. In Experiment 1, participants learned room-sized spatial layouts with or without restriction on direct eye movements to objects. Eye movements were restricted by having participants view the objects through small apertures in front of their eyes. Results showed that impeding effective eye movements made subsequent retrieval of spatial memory slower and less accurate. The small apertures also occluded much of the environmental surroundings, but the importance of this kind of occlusion was ruled out in Experiment 2 by showing that participants exhibited intact learning of the same spatial layouts when luminescent objects were viewed in an otherwise dark room. Together, these findings suggest that one of the roles of peripheral vision in spatial learning is to guide eye movements, highlighting the importance of spatial information derived from eye movements for learning environmental layouts.

  8. The role of peripheral vision in implicit contextual cuing.

    Science.gov (United States)

    van Asselen, Marieke; Castelo-Branco, Miguel

    2009-01-01

    Implicit contextual cuing refers to the ability to learn the association between contextual information of our environment and a specific target, which can be used to guide attention during visual search. It was recently suggested that the storage of a snapshot image of the local context of a target underlies implicit contextual cuing. To make such a snapshot, it is necessary to use peripheral vision. In order to test whether peripheral vision can underlie implicit contextual cuing, we used a covert visual search task, in which participants were required to indicate the orientation of a target stimulus while foveating a fixation cross. The response times were shorter when the configuration of the stimuli was repeated than when the configuration was new. Importantly, this effect was still found after 10 days, indicating that peripherally perceived spatial context information can be stored in memory for long periods of time. These results indicate that peripheral vision can be used to make a snapshot of the local context of a target.

  9. Deployment of spatial attention to words in central and peripheral vision.

    Science.gov (United States)

    Ducrot, Stéphanie; Grainger, Jonathan

    2007-05-01

    Four perceptual identification experiments examined the influence of spatial cues on the recognition of words presented in central vision (with fixation on either the first or last letter of the target word) and in peripheral vision (displaced left or right of a central fixation point). Stimulus location had a strong effect on word identification accuracy in both central and peripheral vision, showing a strong right visual field superiority that did not depend on eccentricity. Valid spatial cues improved word identification for peripherally presented targets but were largely ineffective for centrally presented targets. Effects of spatial cuing interacted with visual field effects in Experiment 1, with valid cues reducing the right visual field superiority for peripherally located targets, but this interaction was shown to depend on the type of neutral cue. These results provide further support for the role of attentional factors in visual field asymmetries obtained with targets in peripheral vision but not with centrally presented targets.

  10. The Development of Peripheral Vision in Infants.

    Science.gov (United States)

    Guez, Jean R.

    This study investigated the extent of infant peripheral vision, specifically the extent of infants' constricted field, or tunnel vision. Thirteen infants, 2 to 5 months old, were tested using a psychophysical procedure to obtain contrast sensitivity thresholds at four retinal loci (-40, -15, +15, +40 deg.). Infants were placed in an infant bed in…

  11. Training improves reading speed in peripheral vision: is it due to attention?

    Science.gov (United States)

    Lee, Hye-Won; Kwon, Miyoung; Legge, Gordon E; Gefroh, Joshua J

    2010-06-01

    Previous research has shown that perceptual training in peripheral vision, using a letter-recognition task, increases reading speed and letter recognition (S. T. L. Chung, G. E. Legge, & S. H. Cheung, 2004). We tested the hypothesis that enhanced deployment of spatial attention to peripheral vision explains this training effect. Subjects were pre- and post-tested with 3 tasks at 10° above and below fixation-RSVP reading speed, trigram letter recognition (used to construct visual-span profiles), and deployment of spatial attention (measured as the benefit of a pre-cue for target position in a lexical-decision task). Groups of five normally sighted young adults received 4 days of trigram letter-recognition training in upper or lower visual fields, or central vision. A control group received no training. Our measure of deployment of spatial attention revealed visual-field anisotropies; better deployment of attention in the lower field than the upper, and in the lower-right quadrant compared with the other three quadrants. All subject groups exhibited slight improvement in deployment of spatial attention to peripheral vision in the post-test, but this improvement was not correlated with training-related increases in reading speed and the size of visual-span profiles. Our results indicate that improved deployment of spatial attention to peripheral vision does not account for improved reading speed and letter recognition in peripheral vision.

  12. Auditory and visual reaction time and peripheral field of vision in helmet users

    Directory of Open Access Journals (Sweden)

    Abbupillai Adhilakshmi

    2016-12-01

    Full Text Available Background: The incidence of fatal accidents are more in two wheeler drivers compared to four wheeler drivers. Head injury is of serious concern when recovery and prognosis of the patients are warranted, helmets are being used for safety purposes by moped, scooters and motorcycle drivers. Although, helmets are designed with cushioning effect to prevent head injuries but there are evidences of increase risk of neck injuries and reduced peripheral vision and hearing in helmet users. A complete full coverage helmets provide about less than 3 percent restrictions in horizontal peripheral visual field compared to rider without helmet. The standard company patented ergonomically designed helmets which does not affect the peripheral vision neither auditory reaction time. Objective: This pilot study aimed to evaluate the peripheral field of vision and auditory and visual reaction time in a hypertensive, diabetic and healthy male and female in order to have a better insight of protective characteristics of helmet in health and disease. Method: This pilot study carried out on age matched male of one healthy, one hypertensive and one diabetic and female subject of one healthy, one hypertensive and one diabetics. The field of vision was assessed by Lister’s perimeter whereas auditory and visual reaction time was recorded with response analyser. Result : Gender difference was not noted in peripheral field of vision but mild difference was found in auditory reaction time for high frequency and visual reaction time for both red and green colour in healthy control. But lateral and downward peripheral visual field was found reduced whereas auditory and visual reaction time was found increased in both hypertensive and diabetic subject in both sexes. Conclusion: Peripheral vision, auditory reaction time and visual reaction time in hypertensive and diabetics may lead to vulnerable accident. Helmet use has proven to reduce extent of injury in motorcyclist and

  13. Training improves reading speed in peripheral vision: Is it due to attention?

    OpenAIRE

    Lee, Hye-Won; Kwon, MiYoung; Legge, Gordon E.; Gefroh, Joshua J.

    2010-01-01

    Previous research has shown that perceptual training in peripheral vision, using a letter-recognition task, increases reading speed and letter recognition (Chung, Legge, & Cheung, 2004). We tested the hypothesis that enhanced deployment of spatial attention to peripheral vision explains this training effect. Subjects were pre- and post-tested with 3 tasks at 10° above and below fixation—RSVP reading speed, trigram letter recognition (used to construct visual-span profiles), and deployment of ...

  14. Which visual sight skill tested and developed the interaction between central and peripheral vision case duels dribbling soccer skills

    Directory of Open Access Journals (Sweden)

    Zerf Mohammed

    2016-09-01

    Full Text Available The present paper analyses the effects of visual keep sight to test and develop the interaction between central and peripheral vision the case of duels dribbling among soccer under 17 years. Where This research aims to propose a method evaluating and coaching this skill in the absence of laboratory tests and virtual visual exercises as a way for Algerian coaches to control the progress of their players. From the principle that the team which wins the most duels has the best chance of winning the game. [1] Our research supports the hypothesis which confirms in one hand that Dynamic visual acuity is the combine between Peripheral and Central vision to have one eye on the ball and the other on the defined [2] . While some authors confirm that the Top-class football players do not watch their steps, but dribble with their heads up [3]. Whereas Previous studies confirm estimate of distance ball foot player is the strategy to master this skill [4] which requires the involvement of the commitment of peripheral vision for information and central vision to master the ball [5]. From the proof and results statistics applied in the current study, we confirm that narrow spaces require the interaction of central vision than peripheral vision. Otherwise, free spaces require peripheral vision than the central vision. Which leaves us to confirm that peripheral vision in the limited space [6] can suffer because the player needs to pay close attention to each contact with the ball [7].

  15. Facilitation of contrast detection in near-peripheral vision.

    Science.gov (United States)

    Giorgi, Robert G; Soong, Grace P; Woods, Russell L; Peli, Eli

    2004-12-01

    Foveal detection of a Gabor patch (target) is facilitated by collinear, displaced high-contrast flankers. Polat and Sagi reported that the same phenomenon occurred in the periphery, but no data were presented [Proc. Natl. Acad. Sci. 91 (1994) 1206]. Others have found no facilitation in a limited number of conditions tested. To resolve this apparent conflict, we measured lateral facilitation in the near-periphery using a range of stimulus parameters. We found facilitation for a range of target-flanker distances for peripheral eccentricities up to 6 degrees , but the magnitude of the effect was less than found in central vision. Facilitation varied across subjects and with spatial frequency. Flanker contrast had no effect over the range evaluated (10-80%). Equal facilitation was found for two global arrangements of the stimulus pattern. Facilitation was found using a temporal, but not a spatial two-alternative forced-choice paradigm, accounting for the different results among previous studies. This finding supports previous indications of the role of attention in altering such facilitation. The value of facilitation from lateral interactions for persons with central vision impairment, who have to shift their attention to a peripheral locus constantly, needs to be examined.

  16. Deaf and Hearing Children: A Comparison of Peripheral Vision Development

    Science.gov (United States)

    Codina, Charlotte; Buckley, David; Port, Michael; Pascalis, Olivier

    2011-01-01

    This study investigated peripheral vision (at least 30[degrees] eccentric to fixation) development in profoundly deaf children without cochlear implantation, and compared this to age-matched hearing controls as well as to deaf and hearing adult data. Deaf and hearing children between the ages of 5 and 15 years were assessed using a new,…

  17. Unconsciously perceived fear in peripheral vision alerts the limbic system: a MEG study.

    Directory of Open Access Journals (Sweden)

    Dimitri J Bayle

    Full Text Available BACKGROUND: In ecological situations, threatening stimuli often come out from the peripheral vision. Such aggressive messages must trigger rapid attention to the periphery to allow a fast and adapted motor reaction. Several clues converge to hypothesize that peripheral danger presentation can trigger off a fast arousal network potentially independent of the consciousness spot. METHODOLOGY/PRINCIPAL FINDINGS: In the present MEG study, spatio-temporal dynamics of the neural processing of danger related stimuli were explored as a function of the stimuli position in the visual field. Fearful and neutral faces were briefly presented in the central or peripheral visual field, and were followed by target faces stimuli. An event-related beamformer source analysis model was applied in three time windows following the first face presentations: 80 to 130 ms, 140 to 190 ms, and 210 to 260 ms. The frontal lobe and the right internal temporal lobe part, including the amygdala, reacted as soon as 80 ms of latency to fear occurring in the peripheral vision. For central presentation, fearful faces evoked the classical neuronal activity along the occipito-temporal visual pathway between 140 and 190 ms. CONCLUSIONS: Thus, the high spatio-temporal resolution of MEG allowed disclosing a fast response of a network involving medial temporal and frontal structures in the processing of fear related stimuli occurring unconsciously in the peripheral visual field. Whereas centrally presented stimuli are precisely processed by the ventral occipito-temporal cortex, the related-to-danger stimuli appearing in the peripheral visual field are more efficient to produce a fast automatic alert response possibly conveyed by subcortical structures.

  18. The role of peripheral vision in saccade planning: learning from people with tunnel vision.

    Science.gov (United States)

    Luo, Gang; Vargas-Martin, Fernando; Peli, Eli

    2008-12-22

    Both visually salient and top-down information are important in eye movement control, but their relative roles in the planning of daily saccades are unclear. We investigated the effect of peripheral vision loss on saccadic behaviors in patients with tunnel vision (visual field diameters 7 degrees-16 degrees) in visual search and real-world walking experiments. The patients made up to two saccades per second to their pre-saccadic blind areas, about half of which had no overlap between the post- and pre-saccadic views. In the visual search experiment, visual field size and the background (blank or picture) did not affect the saccade sizes and direction of patients (n = 9). In the walking experiment, the patients (n = 5) and normal controls (n = 3) had similar distributions of saccade sizes and directions. These findings might provide a clue about the large extent of the top-down mechanism influence on eye movement control.

  19. Foveal and peripheral fields of vision influences perceptual skill in anticipating opponents' attacking position in volleyball.

    Science.gov (United States)

    Schorer, Jörg; Rienhoff, Rebecca; Fischer, Lennart; Baker, Joseph

    2013-09-01

    The importance of perceptual-cognitive expertise in sport has been repeatedly demonstrated. In this study we examined the role of different sources of visual information (i.e., foveal versus peripheral) in anticipating volleyball attack positions. Expert (n = 11), advanced (n = 13) and novice (n = 16) players completed an anticipation task that involved predicting the location of volleyball attacks. Video clips of volleyball attacks (n = 72) were spatially and temporally occluded to provide varying amounts of information to the participant. In addition, participants viewed the attacks under three visual conditions: full vision, foveal vision only, and peripheral vision only. Analysis of variance revealed significant between group differences in prediction accuracy with higher skilled players performing better than lower skilled players. Additionally, we found significant differences between temporal and spatial occlusion conditions. Both of those factors interacted separately, but not combined with expertise. Importantly, for experts the sum of both fields of vision was superior to either source in isolation. Our results suggest different sources of visual information work collectively to facilitate expert anticipation in time-constrained sports and reinforce the complexity of expert perception.

  20. Unsold is unseen … or is it? Examining the role of peripheral vision in the consumer choice process using eye-tracking methodology.

    Science.gov (United States)

    Wästlund, Erik; Shams, Poja; Otterbring, Tobias

    2018-01-01

    In visual marketing, the truism that "unseen is unsold" means that products that are not noticed will not be sold. This truism rests on the idea that the consumer choice process is heavily influenced by visual search. However, given that the majority of available products are not seen by consumers, this article examines the role of peripheral vision in guiding attention during the consumer choice process. In two eye-tracking studies, one conducted in a lab facility and the other conducted in a supermarket, the authors investigate the role and limitations of peripheral vision. The results show that peripheral vision is used to direct visual attention when discriminating between target and non-target objects in an eye-tracking laboratory. Target and non-target similarity, as well as visual saliency of non-targets, constitute the boundary conditions for this effect, which generalizes from instruction-based laboratory tasks to preference-based choice tasks in a real supermarket setting. Thus, peripheral vision helps customers to devote a larger share of attention to relevant products during the consumer choice process. Taken together, the results show how the creation of consideration set (sets of possible choice options) relies on both goal-directed attention and peripheral vision. These results could explain how visually similar packaging positively influences market leaders, while making novel brands almost invisible on supermarket shelves. The findings show that even though unsold products might be unseen, in the sense that they have not been directly observed, they might still have been evaluated and excluded by means of peripheral vision. This article is based on controlled lab experiments as well as a field study conducted in a complex retail environment. Thus, the findings are valid both under controlled and ecologically valid conditions. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Lateralized discrimination of emotional scenes in peripheral vision.

    Science.gov (United States)

    Calvo, Manuel G; Rodríguez-Chinea, Sandra; Fernández-Martín, Andrés

    2015-03-01

    This study investigates whether there is lateralized processing of emotional scenes in the visual periphery, in the absence of eye fixations; and whether this varies with emotional valence (pleasant vs. unpleasant), specific emotional scene content (babies, erotica, human attack, mutilation, etc.), and sex of the viewer. Pairs of emotional (positive or negative) and neutral photographs were presented for 150 ms peripherally (≥6.5° away from fixation). Observers judged on which side the emotional picture was located. Low-level image properties, scene visual saliency, and eye movements were controlled. Results showed that (a) correct identification of the emotional scene exceeded the chance level; (b) performance was more accurate and faster when the emotional scene appeared in the left than in the right visual field; (c) lateralization was equivalent for females and males for pleasant scenes, but was greater for females and unpleasant scenes; and (d) lateralization occurred similarly for different emotional scene categories. These findings reveal discrimination between emotional and neutral scenes, and right brain hemisphere dominance for emotional processing, which is modulated by sex of the viewer and scene valence, and suggest that coarse affective significance can be extracted in peripheral vision.

  2. Toward Vision Oriented Organization through Foresight Capability Development

    Directory of Open Access Journals (Sweden)

    Gianita BLEOJU

    2014-11-01

    Full Text Available Dealing with complexity is becoming increasingly difficult for organizations, due to limited replicable abilities, once management performance was remunerated by successful decisions on the marketplace. The competitive advantage, based upon current documented organizational management expertise, deployed into patterns of competitive behavior, prove to be unsustainable. Therefore, we assist to a relative emergency of strategic intelligence adjustment framework, to channel the managerial capability mechanisms, from current detective orientation capabilities toward anticipatory ones. Based upon exploitation of an organizational profiling database, we try our contribution to this challenging debate, by formulating recommendations for strategic adjustment and prototype testing of the potential solutions, through a designed transition matrix from market oriented to vision oriented organizations.

  3. Effect of peripheral vision training on the attack of beginner indoor soccer players: a study during competition

    Directory of Open Access Journals (Sweden)

    Nelson Kautzner Marques Junior

    2009-01-01

    Full Text Available This study was conducted within the context of Human Motor Skill Science, in the area of Biophysical Dimension and following the research line of the Study of Learning Mechanisms and Processes and of Motor Conduct within the epistemological construct of phenomenological explanation. The objective of this study was to investigate peripheral vision training (PVT and its effect on attack runs during indoor soccer, taking into account dominant laterality (brain hemisphere function in both learning speed andoffensive skills. Ten beginner indoor soccer players aged 10.4 ± 2.31 years, from Lar da Criança Padre Franz Neumair, Ititioca, Niterói, Rio de Janeiro, Brazil, participated in the study. The boys were divided into an experimental group (EG, n = 5 and a controlgroup (CG, n = 5 with similar dominant laterality (brain hemisphere function (H (EG: 80% left H and 20% right H, CG: 60% left H and 40% right H. The players underwent nine training sessions, followed by a championship, and then six additional sessions, followed by a second championship. Each championship was filmed for scoutvideo analysis. Two-way ANOVA revealed a significant difference in peripheral vision during offensive runs between CG and EG, with marked acquisition of peripheral vision in EG. The quality of the attack runs was significant (two-way ANOVA. EG was the better team at the beginning of the attack runs and during attack development, whereas CG was better at attack finalization during the first championship. EG showed more competence in attack run finalization during the second championship. No significant difference in the number of goals scored was observed between the two groups (two-wayANOVA, p>0.05. The frequency of participation in the training sessions was significant (t-test for independent samples, p≤0.05, with EG attending more sessions. In conclusion, EG acquired peripheral vision, a finding suggesting that PVT improves the attack capacity of indoor soccer

  4. Effect of peripheral vision training on the attack of beginner indoor soccer players: a study during competition

    Directory of Open Access Journals (Sweden)

    Nelson Kautzner Marques Junior

    2009-01-01

    Full Text Available http://dx.doi.org/10.5007/1980-0037.2009v11n1p119   In the area of Biophysical Dimension and following the research line of the Study of Learning Mechanisms and Processes and of Motor Conduct within the epistemological construct of phenomenological explanation. The objective of this study was to investigate peripheral vision training (PVT and its effect on attack runs during indoor soccer, taking into account dominant laterality (brain hemisphere function in both learning speed and offensive skills. Ten beginner indoor soccer players aged 10.4 ± 2.31 years, from Lar da Criança Padre Franz Neumair, Ititioca, Niterói, Rio de Janeiro, Brazil, participated in the study. The boys were divided into an experimental group (EG, n = 5 and a control group (CG, n = 5 with similar dominant laterality (brain hemisphere function (H (EG: 80% left H and 20% right H, CG: 60% left H and 40% right H. The players underwent nine training sessions, followed by a championship, and then six additional sessions, followed by a second championship. Each championship was filmed for scout video analysis. Two-way ANOVA revealed a significant difference in peripheral vision during offensive runs between CG and EG, with marked acquisition of peripheral vision in EG. The quality of the attack runs was significant (two-way ANOVA. EG was the better team at the beginning of the attack runs and during attack development, whereas CG was better at attack finalization during the first championship. EG showed more competence in attack run finalization during the second championship. No significant difference in the number of goals scored was observed between the two groups (two-way ANOVA, p>0.05. The frequency of participation in the training sessions was significant (t-test for independent samples, p≤0.05, with EG attending more sessions. In conclusion, EG acquired peripheral vision, a finding suggesting that PVT improves the attack capacity of indoor soccer players.

  5. Sneaking a peek: pigeons use peripheral vision (not mirrors) to find hidden food.

    Science.gov (United States)

    Ünver, Emre; Garland, Alexis; Tabrik, Sepideh; Güntürkün, Onur

    2017-07-01

    A small number of species are capable of recognizing themselves in the mirror when tested with the mark-and-mirror test. This ability is often seen as evidence of self-recognition and possibly even self-awareness. Strangely, a number of species, for example monkeys, pigs and dogs, are unable to pass the mark test but can locate rewarding objects by using the reflective properties of a mirror. Thus, these species seem to understand how a visual reflection functions but cannot apply it to their own image. We tested this discrepancy in pigeons-a species that does not spontaneously pass the mark test. Indeed, we discovered that pigeons can successfully find a hidden food reward using only the reflection, suggesting that pigeons can also use and potentially understand the reflective properties of mirrors, even in the absence of self-recognition. However, tested under monocular conditions, the pigeons approached and attempted to walk through the mirror rather than approach the physical food, displaying similar behavior to patients with mirror agnosia. These findings clearly show that pigeons do not use the reflection of mirrors to locate reward, but actually see the food peripherally with their near-panoramic vision. A re-evaluation of our current understanding of mirror-mediated behavior might be necessary-especially taking more fully into account species differences in visual field. This study suggests that use of reflections in a mirrored surface as a tool may be less widespread than currently thought.

  6. Effect of peripheral vision training on the attack of beginner indoor soccer players: a study during competition

    OpenAIRE

    Nelson Kautzner Marques Junior

    2009-01-01

    This study was conducted within the context of Human Motor Skill Science, in the area of Biophysical Dimension and following the research line of the Study of Learning Mechanisms and Processes and of Motor Conduct within the epistemological construct of phenomenological explanation. The objective of this study was to investigate peripheral vision training (PVT) and its effect on attack runs during indoor soccer, taking into account dominant laterality (brain hemisphere function) in both learn...

  7. Eye guidance during real-world scene search: The role color plays in central and peripheral vision.

    Science.gov (United States)

    Nuthmann, Antje; Malcolm, George L

    2016-01-01

    The visual system utilizes environmental features to direct gaze efficiently when locating objects. While previous research has isolated various features' contributions to gaze guidance, these studies generally used sparse displays and did not investigate how features facilitated search as a function of their location on the visual field. The current study investigated how features across the visual field--particularly color--facilitate gaze guidance during real-world search. A gaze-contingent window followed participants' eye movements, restricting color information to specified regions. Scene images were presented in full color, with color in the periphery and gray in central vision or gray in the periphery and color in central vision, or in grayscale. Color conditions were crossed with a search cue manipulation, with the target cued either with a word label or an exact picture. Search times increased as color information in the scene decreased. A gaze-data based decomposition of search time revealed color-mediated effects on specific subprocesses of search. Color in peripheral vision facilitated target localization, whereas color in central vision facilitated target verification. Picture cues facilitated search, with the effects of cue specificity and scene color combining additively. When available, the visual system utilizes the environment's color information to facilitate different real-world visual search behaviors based on the location within the visual field.

  8. Effect of peripheral vision training on the attack of beginner indoor soccer players: a study during competition

    OpenAIRE

    Nelson Kautzner Marques Junior

    2009-01-01

    http://dx.doi.org/10.5007/1980-0037.2009v11n1p119   In the area of Biophysical Dimension and following the research line of the Study of Learning Mechanisms and Processes and of Motor Conduct within the epistemological construct of phenomenological explanation. The objective of this study was to investigate peripheral vision training (PVT) and its effect on attack runs during indoor soccer, taking into account dominant laterality (brain hemisphere function) in both learning speed and ...

  9. Profile of Low Vision Population Attending Low Vision Clinic in a Peripheral Eye Hospital in Nepal

    OpenAIRE

    Safal Khanal, BOptom; Pekila Lama, MD

    2013-01-01

    Background: Blindness and low vision are major causes of morbidity and constitute a significant public health problem, both detrimental to the quality of life for the individual and an economic burden on the individual, family, and society in general. People with low vision have the potential for enhancement of functional vision if they receive the appropriate low vision services. The present study aims to determine the profile of the low vision population attending a low vision clinic at a p...

  10. Operational Based Vision Assessment Automated Vision Test Collection User Guide

    Science.gov (United States)

    2017-05-15

    AFRL-SA-WP-SR-2017-0012 Operational Based Vision Assessment Automated Vision Test Collection User Guide Elizabeth Shoda, Alex...June 2015 – May 2017 4. TITLE AND SUBTITLE Operational Based Vision Assessment Automated Vision Test Collection User Guide 5a. CONTRACT NUMBER... automated vision tests , or AVT. Development of the AVT was required to support threshold-level vision testing capability needed to investigate the

  11. The role of vision processing in prosthetic vision.

    Science.gov (United States)

    Barnes, Nick; He, Xuming; McCarthy, Chris; Horne, Lachlan; Kim, Junae; Scott, Adele; Lieby, Paulette

    2012-01-01

    Prosthetic vision provides vision which is reduced in resolution and dynamic range compared to normal human vision. This comes about both due to residual damage to the visual system from the condition that caused vision loss, and due to limitations of current technology. However, even with limitations, prosthetic vision may still be able to support functional performance which is sufficient for tasks which are key to restoring independent living and quality of life. Here vision processing can play a key role, ensuring that information which is critical to the performance of key tasks is available within the capability of the available prosthetic vision. In this paper, we frame vision processing for prosthetic vision, highlight some key areas which present problems in terms of quality of life, and present examples where vision processing can help achieve better outcomes.

  12. 75 FR 9480 - Qualification of Drivers; Exemption Applications; Vision

    Science.gov (United States)

    2010-03-02

    ... injury sustained as a child. The best corrected visual acuity in his right eye is light-perception only... medical opinion, Mr. Williford has sufficient visual acuity, color vision and peripheral vision to perform...

  13. Development and evaluation of vision rehabilitation devices.

    Science.gov (United States)

    Luo, Gang; Peli, Eli

    2011-01-01

    We have developed a range of vision rehabilitation devices and techniques for people with impaired vision due to either central vision loss or severely restricted peripheral visual field. We have conducted evaluation studies with patients to test the utilities of these techniques in an effort to document their advantages as well as their limitations. Here we describe our work on a visual field expander based on a head mounted display (HMD) for tunnel vision, a vision enhancement device for central vision loss, and a frequency domain JPEG/MPEG based image enhancement technique. All the evaluation studies included visual search paradigms that are suitable for conducting indoor controllable experiments.

  14. Common constraints limit Korean and English character recognition in peripheral vision.

    Science.gov (United States)

    He, Yingchen; Kwon, MiYoung; Legge, Gordon E

    2018-01-01

    The visual span refers to the number of adjacent characters that can be recognized in a single glance. It is viewed as a sensory bottleneck in reading for both normal and clinical populations. In peripheral vision, the visual span for English characters can be enlarged after training with a letter-recognition task. Here, we examined the transfer of training from Korean to English characters for a group of bilingual Korean native speakers. In the pre- and posttests, we measured visual spans for Korean characters and English letters. Training (1.5 hours × 4 days) consisted of repetitive visual-span measurements for Korean trigrams (strings of three characters). Our training enlarged the visual spans for Korean single characters and trigrams, and the benefit transferred to untrained English symbols. The improvement was largely due to a reduction of within-character and between-character crowding in Korean recognition, as well as between-letter crowding in English recognition. We also found a negative correlation between the size of the visual span and the average pattern complexity of the symbol set. Together, our results showed that the visual span is limited by common sensory (crowding) and physical (pattern complexity) factors regardless of the language script, providing evidence that the visual span reflects a universal bottleneck for text recognition.

  15. DEVELOPMENT OF TECHNOLOGIES AND ANALYTICAL CAPABILITIES FOR VISION 21 ENERGY PLANTS

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell Osawe; Madhave Symlal; Krishna Thotapalli; and Stephen Zitney

    2003-04-30

    This is the tenth Quarterly Technical Report for DOE Cooperative Agreement No: DE-FC26-00NT40954. The goal of the project is to develop and demonstrate a software framework to enable virtual simulation of Vision 21 plants. During the last quarter much progress was made in software development. The CO wrapper template was developed for the integration of Alstom Power proprietary code INDVU. The session management tasks were completed. The multithreading capability was made functional so that user of the integrated simulation may directly interact with the CFD software. The V21-Controller and the Fluent CO wrapper were upgraded to CO v.1.0. The testing and debugging of the upgraded software is ongoing. Testing of the integrated software was continued. A list of suggested GUI enhancements was made. Remote simulation capability was successfully tested using two networked Windows machines. Work on preparing the release version progressed: CFD database was enhanced, a convergence detection capability was implemented, a Configuration Wizard for low-order models was developed, and the Configuration Wizard for Fluent was enhanced. During the last quarter good progress was made in software demonstration. Various simplified versions of Demo Case 1 were used to debug Configuration Wizard and V21-Controller. The heat exchanger model in FLUENT was calibrated and the energy balance was verified. The INDVU code was integrated into the V21-Controller, and the integrated model is being debugged. A sensitivity loop was inserted into Demo Case 2 to check whether the simulation converges over the desired load range. Work on converting HRSGSIM code to run in batch mode was started. Work on calibrating Demo Case 2 was started.

  16. 16 CFR 1203.14 - Peripheral vision test.

    Science.gov (United States)

    2010-01-01

    ....14 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS... from each side of the midsagittal plane around the point K (see Figure 6 of this part). Point K is... planes. The vision shall not be obstructed within 105 degrees from point K on each side of the...

  17. Assistive peripheral phosphene arrays deliver advantages in obstacle avoidance in simulated end-stage retinitis pigmentosa: a virtual-reality study

    Science.gov (United States)

    Zapf, Marc Patrick H.; Boon, Mei-Ying; Lovell, Nigel H.; Suaning, Gregg J.

    2016-04-01

    Objective. The prospective efficacy of peripheral retinal prostheses for guiding orientation and mobility in the absence of residual vision, as compared to an implant for the central visual field (VF), was evaluated using simulated prosthetic vision (SPV). Approach. Sighted volunteers wearing a head-mounted display performed an obstacle circumvention task under SPV. Mobility and orientation performance with three layouts of prosthetic vision were compared: peripheral prosthetic vision of higher visual acuity (VA) but limited VF, of wider VF but limited VA, as well as centrally restricted prosthetic vision. Learning curves using these layouts were compared fitting an exponential model to the mobility and orientation measures. Main results. Using peripheral layouts, performance was superior to the central layout. Walking speed with both higher-acuity and wider-angle layouts was 5.6% higher, and mobility errors reduced by 46.4% and 48.6%, respectively, as compared to the central layout. The wider-angle layout yielded the least number of collisions, 63% less than the higher-acuity and 73% less than the central layout. Using peripheral layouts, the number of visual-scanning related head movements was 54.3% (higher-acuity) and 60.7% (wider-angle) lower, as compared to the central layout, and the ratio of time standing versus time walking was 51.9% and 61.5% lower, respectively. Learning curves did not differ between layouts, except for time standing versus time walking, where both peripheral layouts achieved significantly lower asymptotic values compared to the central layout. Significance. Beyond complementing residual vision for an improved performance, peripheral prosthetic vision can effectively guide mobility in the later stages of retinitis pigmentosa (RP) without residual vision. Further, the temporal dynamics of learning peripheral and central prosthetic vision are similar. Therefore, development of a peripheral retinal prosthesis and early implantation to

  18. Biofeedback for Better Vision

    Science.gov (United States)

    1990-01-01

    Biofeedtrac, Inc.'s Accommotrac Vision Trainer, invented by Dr. Joseph Trachtman, is based on vision research performed by Ames Research Center and a special optometer developed for the Ames program by Stanford Research Institute. In the United States, about 150 million people are myopes (nearsighted), who tend to overfocus when they look at distant objects causing blurry distant vision, or hyperopes (farsighted), whose vision blurs when they look at close objects because they tend to underfocus. The Accommotrac system is an optical/electronic system used by a doctor as an aid in teaching a patient how to contract and relax the ciliary body, the focusing muscle. The key is biofeedback, wherein the patient learns to control a bodily process or function he is not normally aware of. Trachtman claims a 90 percent success rate for correcting, improving or stopping focusing problems. The Vision Trainer has also proved effective in treating other eye problems such as eye oscillation, cross eyes, and lazy eye and in professional sports to improve athletes' peripheral vision and reaction time.

  19. The Charles F. Prentice Award Lecture 2010: A Case for Peripheral Optical Treatment Strategies for Myopia

    Science.gov (United States)

    Smith, Earl L.

    2011-01-01

    It is well established that refractive development is regulated by visual feedback. However, most optical treatment strategies designed to reduce myopia progression have not produced the desired results, primarily because some of our assumptions concerning the operating characteristics of the vision-dependent mechanisms that regulate refractive development have been incorrect. In particular, because of the prominence of central vision in primates, it has generally been assumed that signals from the fovea determine the effects of vision on refractive development. However, experiments in laboratory animals demonstrate that ocular growth and emmetropization are mediated by local retinal mechanisms and that foveal vision is not essential for many vision-dependent aspects of refractive development. On the other hand, the peripheral retina, in isolation, can effectively regulate emmetropization and mediate many of the effects of vision on the eye’s refractive status. Moreover, when there are conflicting visual signals between the fovea and the periphery, peripheral vision can dominate refractive development. The overall pattern of results suggests that optical treatment strategies for myopia that take into account the effects of peripheral vision are likely to be more successful than strategies that effectively manipulate only central vision. PMID:21747306

  20. Vision-based interaction

    CERN Document Server

    Turk, Matthew

    2013-01-01

    In its early years, the field of computer vision was largely motivated by researchers seeking computational models of biological vision and solutions to practical problems in manufacturing, defense, and medicine. For the past two decades or so, there has been an increasing interest in computer vision as an input modality in the context of human-computer interaction. Such vision-based interaction can endow interactive systems with visual capabilities similar to those important to human-human interaction, in order to perceive non-verbal cues and incorporate this information in applications such

  1. Peripheral vision and perceptual asymmetries in young and older martial arts athletes and nonathletes.

    Science.gov (United States)

    Muiños, Mónica; Ballesteros, Soledad

    2014-11-01

    The present study investigated peripheral vision (PV) and perceptual asymmetries in young and older martial arts athletes (judo and karate athletes) and compared their performance with that of young and older nonathletes. Stimuli were dots presented at three different eccentricities along the horizontal, oblique, and vertical diameters and three interstimulus intervals. Experiment 1 showed that although the two athlete groups were faster in almost all conditions, karate athletes performed significantly better than nonathlete participants when stimuli were presented in the peripheral visual field. Experiment 2 showed that older participants who had practiced a martial art at a competitive level when they were young were significantly faster than sedentary older adults of the same age. The practiced sport (judo or karate) did not affect performance differentially, suggesting that it is the practice of martial arts that is the crucial factor, rather than the type of martial art. Importantly, older athletes lose their PV advantage, as compared with young athletes. Finally, we found that physical activity (young and older athletes) and age (young and older adults) did not alter the visual asymmetries that vary as a function of spatial location; all participants were faster for stimuli presented along the horizontal than for those presented along the vertical meridian and for those presented at the lower rather than at the upper locations within the vertical meridian. These results indicate that the practice of these martial arts is an effective way of counteracting the processing speed decline of visual stimuli appearing at any visual location and speed.

  2. 78 FR 12815 - Qualification of Drivers; Exemption Applications; Vision

    Science.gov (United States)

    2013-02-25

    .... The best corrected visual acuity in his right eye is light perception, and in his left eye, 20/20.... Lifelong. Stable. Visual fields WNL. Color WNL. No contraindications for commercial driving.'' Mr. Clark... color vision, 180 degrees of peripheral vision, no medical contraindication to commercial truck driving...

  3. Multi-capability color night vision HD camera for defense, surveillance, and security

    Science.gov (United States)

    Pang, Francis; Powell, Gareth; Fereyre, Pierre

    2015-05-01

    e2v has developed a family of high performance cameras based on our next generation CMOS imagers that provide multiple features and capabilities to meet the range of challenging imaging applications in defense, surveillance, and security markets. Two resolution sizes are available: 1920x1080 with 5.3 μm pixels, and an ultra-low light level version at 1280x1024 with 10μm pixels. Each type is available in either monochrome or e2v's unique bayer pattern color version. The camera is well suited to accommodate many of the high demands for defense, surveillance, and security applications: compact form factor (SWAP+C), color night vision performance (down to 10-2 lux), ruggedized housing, Global Shutter, low read noise (<6e- in Global shutter mode and <2.5e- in Rolling shutter mode), 60 Hz frame rate, high QE especially in the enhanced NIR range (up to 1100nm). Other capabilities include active illumination and range gating. This paper will describe all the features of the sensor and the camera. It will be followed with a presentation of the latest test data with the current developments. Then, it will conclude with a description of how these features can be easily configured to meet many different applications. With this development, we can tune rather than create a full customization, making it more beneficial for many of our customers and their custom applications.

  4. Peripheral visual performance enhancement by neurofeedback training.

    Science.gov (United States)

    Nan, Wenya; Wan, Feng; Lou, Chin Ian; Vai, Mang I; Rosa, Agostinho

    2013-12-01

    Peripheral visual performance is an important ability for everyone, and a positive inter-individual correlation is found between the peripheral visual performance and the alpha amplitude during the performance test. This study investigated the effect of alpha neurofeedback training on the peripheral visual performance. A neurofeedback group of 13 subjects finished 20 sessions of alpha enhancement feedback within 20 days. The peripheral visual performance was assessed by a new dynamic peripheral visual test on the first and last training day. The results revealed that the neurofeedback group showed significant enhancement of the peripheral visual performance as well as the relative alpha amplitude during the peripheral visual test. It was not the case in the non-neurofeedback control group, which performed the tests within the same time frame as the neurofeedback group but without any training sessions. These findings suggest that alpha neurofeedback training was effective in improving peripheral visual performance. To the best of our knowledge, this is the first study to show evidence for performance improvement in peripheral vision via alpha neurofeedback training.

  5. Low Vision Devices and Training

    Directory of Open Access Journals (Sweden)

    Imran Azam Butt

    2004-01-01

    Full Text Available Vision is the ability to see with a clear perception of detail, colour and contrast, and to distinguish objects visually. Like any other sense, vision tends to deteriorate or diminish naturally with age. In most cases, reduction in visual capability can be corrected with glasses, medicine or surgery. However, if the visual changes occur because of an incurable eye disease, condition or injury, vision loss can be permanent. Many people around the world with permanent visual impairment have some residual vision which can be used with the help of low vision services, materials and devices. This paper describes different options for the enhancement of residual vision including optical and non-optical devices and providing training for the low vision client.

  6. An Exploratory Study of the Potential Effects of Vision Training on Concussion Incidence in Football

    OpenAIRE

    Joseph F. Clark, PHD, ATC; Pat Graman, MA, ATC; James K. Ellis, OD; Robert E. Mangine, MEd, PT, ATC; Joesph T. Rauch, DPT, SCS, ATC; Ben Bixenmann, MD; Kimberly A. Hasselfeld, MS; Jon G. Divine, MD; Angelo J. Colosimo, MD; Gregory D. Myer, PhD, FACSM

    2015-01-01

    Background: Vision training has become a component of sports enhancement training; however, quantifiable and validated improvement in visual performance has not been clearly demonstrated. In addition, there is minimal literature related to the effects of vision training on sports performance and injury risk reduction. The purpose of the current investigation was to determine the effects of vision training on peripheral vision and concussion incidence. Methods: Vision training was initiate...

  7. Central and Peripheral Vision Loss Differentially Affects Contextual Cueing in Visual Search

    Science.gov (United States)

    Geringswald, Franziska; Pollmann, Stefan

    2015-01-01

    Visual search for targets in repeated displays is more efficient than search for the same targets in random distractor layouts. Previous work has shown that this contextual cueing is severely impaired under central vision loss. Here, we investigated whether central vision loss, simulated with gaze-contingent displays, prevents the incidental…

  8. Examining Vision and Attention in Sports Performance Using a Gaze-Contingent Paradigm

    Directory of Open Access Journals (Sweden)

    Donghyun Ryu

    2012-10-01

    Full Text Available In time-constrained activities, such as competitive sports, the rapid acquisition and comprehension of visual information is vital for successful performance. Currently our understanding of how and what visual information is acquired and how this changes with skill development is quite rudimentary. Interpretation of eye movement behaviour is limited by uncertainties surrounding the relationship between attention, line-of-gaze data, and the mechanism of information pick-up from different sectors of the visual field. We used gaze-contingent display methodology to provide a selective information presentation to the central and peripheral parts of the visual field while performing a decision-making task. Eleven skilled and 11 less-skilled players watched videos of basketball scenarios under three different vision conditions (tunnel, masked, and full vision and in a forced-choice paradigm responded whether it was more appropriate for the ball carrier to pass or drive. In the tunnel and mask conditions vision was selectively restricted to, or occluded from, 5o around the line of gaze respectively. The skilled players showed significantly higher response accuracy and faster response times compared to their lesser skilled counterparts irrespective of the vision condition, demonstrating the skilled players' superiority in information extraction irrespective of the segment of visual field they rely on. Findings suggest that the capability to interpret visual information appears to be the key limiting factor to expert performance rather than the sector of the visual field in which the information is detected.

  9. Towards an assistive peripheral visual prosthesis for long-term treatment of retinitis pigmentosa: evaluating mobility performance in immersive simulations

    Science.gov (United States)

    Zapf, Marc Patrick H.; Boon, Mei-Ying; Matteucci, Paul B.; Lovell, Nigel H.; Suaning, Gregg J.

    2015-06-01

    Objective. The prospective efficacy of a future peripheral retinal prosthesis complementing residual vision to raise mobility performance in non-end stage retinitis pigmentosa (RP) was evaluated using simulated prosthetic vision (SPV). Approach. Normally sighted volunteers were fitted with a wide-angle head-mounted display and carried out mobility tasks in photorealistic virtual pedestrian scenarios. Circumvention of low-lying obstacles, path following, and navigating around static and moving pedestrians were performed either with central simulated residual vision of 10° alone or enhanced by assistive SPV in the lower and lateral peripheral visual field (VF). Three layouts of assistive vision corresponding to hypothetical electrode array layouts were compared, emphasizing higher visual acuity, a wider visual angle, or eccentricity-dependent acuity across an intermediate angle. Movement speed, task time, distance walked and collisions with the environment were analysed as performance measures. Main results. Circumvention of low-lying obstacles was improved with all tested configurations of assistive SPV. Higher-acuity assistive vision allowed for greatest improvement in walking speeds—14% above that of plain residual vision, while only wide-angle and eccentricity-dependent vision significantly reduced the number of collisions—both by 21%. Navigating around pedestrians, there were significant reductions in collisions with static pedestrians by 33% and task time by 7.7% with the higher-acuity layout. Following a path, higher-acuity assistive vision increased walking speed by 9%, and decreased collisions with stationary cars by 18%. Significance. The ability of assistive peripheral prosthetic vision to improve mobility performance in persons with constricted VFs has been demonstrated. In a prospective peripheral visual prosthesis, electrode array designs need to be carefully tailored to the scope of tasks in which a device aims to assist. We posit that maximum

  10. Panoramic stereo sphere vision

    Science.gov (United States)

    Feng, Weijia; Zhang, Baofeng; Röning, Juha; Zong, Xiaoning; Yi, Tian

    2013-01-01

    Conventional stereo vision systems have a small field of view (FOV) which limits their usefulness for certain applications. While panorama vision is able to "see" in all directions of the observation space, scene depth information is missed because of the mapping from 3D reference coordinates to 2D panoramic image. In this paper, we present an innovative vision system which builds by a special combined fish-eye lenses module, and is capable of producing 3D coordinate information from the whole global observation space and acquiring no blind area 360°×360° panoramic image simultaneously just using single vision equipment with one time static shooting. It is called Panoramic Stereo Sphere Vision (PSSV). We proposed the geometric model, mathematic model and parameters calibration method in this paper. Specifically, video surveillance, robotic autonomous navigation, virtual reality, driving assistance, multiple maneuvering target tracking, automatic mapping of environments and attitude estimation are some of the applications which will benefit from PSSV.

  11. The risk of pedestrian collisions with peripheral visual field loss

    OpenAIRE

    Peli, Eli; Apfelbaum, Henry; Berson, Eliot L.; Goldstein, Robert B.

    2016-01-01

    Patients with peripheral field loss complain of colliding with other pedestrians in open-space environments such as shopping malls. Field expansion devices (e.g., prisms) can create artificial peripheral islands of vision. We investigated the visual angle at which these islands can be most effective for avoiding pedestrian collisions, by modeling the collision risk density as a function of bearing angle of pedestrians relative to the patient. Pedestrians at all possible locations were assumed...

  12. Are Visual Peripheries Forever Young?

    Directory of Open Access Journals (Sweden)

    Kalina Burnat

    2015-01-01

    Full Text Available The paper presents a concept of lifelong plasticity of peripheral vision. Central vision processing is accepted as critical and irreplaceable for normal perception in humans. While peripheral processing chiefly carries information about motion stimuli features and redirects foveal attention to new objects, it can also take over functions typical for central vision. Here I review the data showing the plasticity of peripheral vision found in functional, developmental, and comparative studies. Even though it is well established that afferent projections from central and peripheral retinal regions are not established simultaneously during early postnatal life, central vision is commonly used as a general model of development of the visual system. Based on clinical studies and visually deprived animal models, I describe how central and peripheral visual field representations separately rely on early visual experience. Peripheral visual processing (motion is more affected by binocular visual deprivation than central visual processing (spatial resolution. In addition, our own experimental findings show the possible recruitment of coarse peripheral vision for fine spatial analysis. Accordingly, I hypothesize that the balance between central and peripheral visual processing, established in the course of development, is susceptible to plastic adaptations during the entire life span, with peripheral vision capable of taking over central processing.

  13. Are visual peripheries forever young?

    Science.gov (United States)

    Burnat, Kalina

    2015-01-01

    The paper presents a concept of lifelong plasticity of peripheral vision. Central vision processing is accepted as critical and irreplaceable for normal perception in humans. While peripheral processing chiefly carries information about motion stimuli features and redirects foveal attention to new objects, it can also take over functions typical for central vision. Here I review the data showing the plasticity of peripheral vision found in functional, developmental, and comparative studies. Even though it is well established that afferent projections from central and peripheral retinal regions are not established simultaneously during early postnatal life, central vision is commonly used as a general model of development of the visual system. Based on clinical studies and visually deprived animal models, I describe how central and peripheral visual field representations separately rely on early visual experience. Peripheral visual processing (motion) is more affected by binocular visual deprivation than central visual processing (spatial resolution). In addition, our own experimental findings show the possible recruitment of coarse peripheral vision for fine spatial analysis. Accordingly, I hypothesize that the balance between central and peripheral visual processing, established in the course of development, is susceptible to plastic adaptations during the entire life span, with peripheral vision capable of taking over central processing.

  14. Vision Related Quality of Life in Patients with Keratoconus

    Directory of Open Access Journals (Sweden)

    Sevda Aydin Kurna

    2014-01-01

    Full Text Available Purpose. The purpose of this study is to evaluate the vision related quality of life in patients with keratoconus by using the National Eye Institute Visual Function Questionnaire-25 (NEI-VFQ-25. Methods. Thirty patients presented with keratoconus (keratoconus group and 30 healthy patients (control group were included in this study. Twenty patients were using rigid gas permeable and 10 patients were not using contact lenses in keratoconus group. High and low contrast visual acuity and mean K values of the patients were recorded. Each subject completed the 25-item NEI-VFQ-25. Results. All subscales of NEI-VFQ-25 were lower in the keratoconus patients. The difference was more evident in the subscales of general vision, ocular pain, near vision, vision-specific mental health, vision-specific role difficulties, and peripheral vision P 0.4 in the better eye had lower distance vision, social functioning, mental health, and role difficulties. Meanwhile, patients with low visual acuity (logMAR > 0.4 in the worse eye had lower general health scores P<0.05. Conclusions. Vision related quality of life was worse in keratoconus patients. Success in the contact lens usage and maintaining higher visual acuity may improve vision related quality of life.

  15. Vision-based autonomous grasping of unknown piled objects

    International Nuclear Information System (INIS)

    Johnson, R.K.

    1994-01-01

    Computer vision techniques have been used to develop a vision-based grasping capability for autonomously picking and placing unknown piled objects. This work is currently being applied to the problem of hazardous waste sorting in support of the Department of Energy's Mixed Waste Operations Program

  16. Peripheral neuropathy: an often-overlooked cause of falls in the elderly.

    Science.gov (United States)

    Richardson, J K; Ashton-Miller, J A

    1996-06-01

    Peripheral neuropathy is common in the elderly and results in impairments in distal proprioception and strength that hinder balance and predispose them to falls. The loss of heel reflexes, decreased vibratory sense that improves proximally, impaired position sense at the great toe, and inability to maintain unipedal stance for 10 seconds in three attempts all suggest functionally significant peripheral neuropathy. Physicians can help their patients with peripheral neuropathy to prevent falls by teaching them and their families about peripheral nerve dysfunction and its effects on balance and by advising patients to substitute vision for the lost somatosensory function, correctly use a cane, wear proper shoes and orthotics, and perform balance and upper extremity strengthening exercises.

  17. [RESEARCH PROGRESS OF PERIPHERAL NERVE SURGERY ASSISTED BY Da Vinci ROBOTIC SYSTEM].

    Science.gov (United States)

    Shen, Jie; Song, Diyu; Wang, Xiaoyu; Wang, Changjiang; Zhang, Shuming

    2016-02-01

    To summarize the research progress of peripheral nerve surgery assisted by Da Vinci robotic system. The recent domestic and international articles about peripheral nerve surgery assisted by Da Vinci robotic system were reviewed and summarized. Compared with conventional microsurgery, peripheral nerve surgery assisted by Da Vinci robotic system has distinctive advantages, such as elimination of physiological tremors and three-dimensional high-resolution vision. It is possible to perform robot assisted limb nerve surgery using either the traditional brachial plexus approach or the mini-invasive approach. The development of Da Vinci robotic system has revealed new perspectives in peripheral nerve surgery. But it has still been at the initial stage, more basic and clinical researches are still needed.

  18. Using optic flow in the far peripheral field.

    Science.gov (United States)

    McManus, Meaghan; D'Amour, Sarah; Harris, Laurence R

    2017-07-01

    Self-motion information can be used to update spatial memory of location through an estimate of a change in position. Viewing optic flow alone can create Illusory self-motion or "vection." Early studies suggested that peripheral vision is more effective than central vision in evoking vection, but controlling for retinal area and perceived distance suggests that all retinal areas may be equally effective. However, the contributions of the far periphery, beyond 90°, have been largely neglected. Using a large-field Edgeless Graphics Geometry display (EGG, Christie, Canada, field of view ±112°) and systematically blocking central (±20° to ±90°) or peripheral (viewing through tunnels ±20° to ±40°) parts of the field, we compared the effectiveness of different retinal regions at evoking forwards linear vection. Fifteen participants indicated when they had reached the position of a previously presented target after visually simulating motion down a simulated corridor. The amount of simulated travel needed to match a given target distance was modelled with a leaky spatial integrator model to estimate gains (perceived/actual distance) and a spatial decay factor. When optic flow was presented only in the far periphery (beyond 90°) gains were significantly higher than for the same motion presented full field or in only the central field, resulting in accurate performance in the range of speeds associated with normal walking. The increased effectiveness of optic flow in the peripheral field alone compared to full-field motion is discussed in terms of emerging neurophysiological studies that suggest brain areas dedicated to processing information from the far peripheral field.

  19. GPS Usage in a Population of Low-Vision Drivers.

    Science.gov (United States)

    Cucuras, Maria; Chun, Robert; Lee, Patrick; Jay, Walter M; Pusateri, Gregg

    2017-01-01

    We surveyed bioptic and non-bioptic low-vision drivers in Illinois, USA, to determine their usage of global positioning system (GPS) devices. Low-vision patients completed an IRB-approved phone survey regarding driving demographics and usage of GPS while driving. Participants were required to be active drivers with an Illinois driver's license, and met one of the following criteria: best-corrected visual acuity (BCVA) less than or equal to 20/40, central or significant peripheral visual field defects, or a combination of both. Of 27 low-vision drivers, 10 (37%) used GPS while driving. The average age for GPS users was 54.3 and for non-users was 77.6. All 10 drivers who used GPS while driving reported increased comfort or safety level. Since non-GPS users were significantly older than GPS users, it is likely that older participants would benefit from GPS technology training from their low-vision eye care professionals.

  20. Vision related quality of life in patients with type 2 diabetes in the EUROCONDOR trial.

    Science.gov (United States)

    Trento, Marina; Durando, Olga; Lavecchia, Sonia; Charrier, Lorena; Cavallo, Franco; Costa, Miguel Angelo; Hernández, Cristina; Simó, Rafael; Porta, Massimo

    2017-07-01

    To evaluate vision related quality of life in the patients enrolled in The European Consortium for the Early Treatment of Diabetic Retinopathy, a clinical trial on prevention of diabetic retinopathy. Four-hundred-forty-nine patients, 153 women, with type 2 Diabetes and no or mild diabetic retinopathy were enrolled in a 2-year multicenter randomized controlled trial. The 25-item National Eye Institute Visual Functioning Questionnaire was used to explore 12 subscales of vision related quality of life. The patients were 62.8 ± 6.7 years old and had 11.1 ± 5.6 years known disease duration. Diabetic retinopathy was absent in 193 (43.0 %) and mild in 256 (57.0 %). Patients without diabetic retinopathy were older, had shorter diabetes duration and used less insulin and glucose-lowering agents but did not differ by gender, best corrected visual acuity or any subscale, except vision specific mental health and vision specific role difficulties. Patients with reduced retinal thickness at the ganglion cell layer (n = 36) did not differ for diabetic retinopathy but were older, had lower best corrected visual acuity and worse scores for ocular pain, color vision and peripheral vision. On multivariable analysis, worse scores for general vision remained associated with reduced retinal thickness, diabetes duration and best corrected visual acuity, and scores for visual specific mental health with diabetic retinopathy and lower best corrected visual acuity. Visual specific role difficulties were only associated with reduced best corrected visual acuity. Scores for driving decreased among females, with worsening of Hemoglobin A1c and best corrected visual acuity. Color vision depended only on reduced retinal thickness, and peripheral vision on both reduced thickness and best corrected visual acuity. The National Eye Institute Visual Functioning Questionnaire could detect subtle changes in patients' perception of visual function, despite absent/minimal diabetic

  1. A Review: E. Peeren, H. Stuit, A. Van Weyenberg (eds., "Peripheral Visions in The Globalizing Present, Space, Mobility, Aesthetics" (Leide, Boston: Brill, 2016

    Directory of Open Access Journals (Sweden)

    Elia Zaru

    2016-12-01

    Full Text Available In 1980 Gilles Deleuze and Félix Guattari published Mille Plateaux, in which they theorized the philosophical concept of the “rhizome”. With such a notion, the two scholars aimed at breaking any hierarchical ontology. Instead of assuming a situated and territorialized point of view, they argued, the “rhizome” specifically allows the deterritorialization of being, and offers a peripheral vision of the world by excluding the existence of a defined centre. The “rhizome” contrasts what the two authors called an “arborescent” conception of knowledge, characterized by a precise hierarchic form. While in the former every point is necessarily related to each single other, the latter functions exactly by fixing a set of principal points which follow an exclusion principle. The “arborescent” scheme proceeds through dichotomy and hierarchy, and prevents the undesirable connections.

  2. Increased generalization capability of trainable COSFIRE filters with application to machine vision

    NARCIS (Netherlands)

    Azzopardi, George; Fernandez-Robles, Laura; Alegre, Enrique; Petkov, Nicolai

    2017-01-01

    The recently proposed trainable COSFIRE filters are highly effective in a wide range of computer vision applications, including object recognition, image classification, contour detection and retinal vessel segmentation. A COSFIRE filter is selective for a collection of contour parts in a certain

  3. Machine Learning for Robotic Vision

    OpenAIRE

    Drummond, Tom

    2018-01-01

    Machine learning is a crucial enabling technology for robotics, in particular for unlocking the capabilities afforded by visual sensing. This talk will present research within Prof Drummond’s lab that explores how machine learning can be developed and used within the context of Robotic Vision.

  4. Robot vision

    International Nuclear Information System (INIS)

    Hall, E.L.

    1984-01-01

    Almost all industrial robots use internal sensors such as shaft encoders which measure rotary position, or tachometers which measure velocity, to control their motions. Most controllers also provide interface capabilities so that signals from conveyors, machine tools, and the robot itself may be used to accomplish a task. However, advanced external sensors, such as visual sensors, can provide a much greater degree of adaptability for robot control as well as add automatic inspection capabilities to the industrial robot. Visual and other sensors are now being used in fundamental operations such as material processing with immediate inspection, material handling with adaption, arc welding, and complex assembly tasks. A new industry of robot vision has emerged. The application of these systems is an area of great potential

  5. Evaluation of a Portable Collision Warning Device for Patients With Peripheral Vision Loss in an Obstacle Course.

    Science.gov (United States)

    Pundlik, Shrinivas; Tomasi, Matteo; Luo, Gang

    2015-04-01

    A pocket-sized collision warning device equipped with a video camera was developed to predict impending collisions based on time to collision rather than proximity. A study was conducted in a high-density obstacle course to evaluate the effect of the device on collision avoidance in people with peripheral field loss (PFL). The 41-meter-long loop-shaped obstacle course consisted of 46 stationary obstacles from floor to head level and oncoming pedestrians. Twenty-five patients with tunnel vision (n = 13) or hemianopia (n = 12) completed four consecutive loops with and without the device, while not using any other habitual mobility aid. Walking direction and device usage order were counterbalanced. Number of collisions and preferred percentage of walking speed (PPWS) were compared within subjects. Collisions were reduced significantly by approximately 37% (P < 0.001) with the device (floor-level obstacles were excluded because the device was not designed for them). No patient had more collisions when using the device. Although the PPWS were also reduced with the device from 52% to 49% (P = 0.053), this did not account for the lower number of collisions, as the changes in collisions and PPWS were not correlated (P = 0.516). The device may help patients with a wide range of PFL avoid collisions with high-level obstacles while barely affecting their walking speed.

  6. Augmentation of Cognition and Perception Through Advanced Synthetic Vision Technology

    Science.gov (United States)

    Prinzel, Lawrence J., III; Kramer, Lynda J.; Bailey, Randall E.; Arthur, Jarvis J.; Williams, Steve P.; McNabb, Jennifer

    2005-01-01

    Synthetic Vision System technology augments reality and creates a virtual visual meteorological condition that extends a pilot's cognitive and perceptual capabilities during flight operations when outside visibility is restricted. The paper describes the NASA Synthetic Vision System for commercial aviation with an emphasis on how the technology achieves Augmented Cognition objectives.

  7. Visual search in the real world: Color vision deficiency affects peripheral guidance, but leaves foveal verification largely unaffected

    Directory of Open Access Journals (Sweden)

    Günter eKugler

    2015-12-01

    Full Text Available Background: People with color vision deficiencies report numerous limitations in daily life. However, they use basic color terms systematically and in a similar manner as people with people with normal color vision. We hypothesize that a possible explanation for this discrepancy between color perception and behavioral consequences might be found in the gaze behavior of people with color vision deficiency.Methods: A group of participants with color vision deficiencies and a control group performed several search tasks in a naturalistic setting on a lawn.Results: Search performance was similar in both groups in a color-unrelated search task as well as in a search for yellow targets. While searching for red targets, color vision deficient participants exhibited a strongly degraded performance. This was closely matched by the number of fixations on red objects shown by the two groups. Importantly, once they fixated a target, participants with color vision deficiencies exhibited only few identification errors. Conclusions: Participants with color vision deficiencies are not able to enhance their search for red targets on a (green lawn by an efficient guiding mechanism. The data indicate that the impaired guiding is the main influence on search performance, while foveal identification (verification largely unaffected.

  8. Emotional facial expression detection in the peripheral visual field.

    Directory of Open Access Journals (Sweden)

    Dimitri J Bayle

    Full Text Available BACKGROUND: In everyday life, signals of danger, such as aversive facial expressions, usually appear in the peripheral visual field. Although facial expression processing in central vision has been extensively studied, this processing in peripheral vision has been poorly studied. METHODOLOGY/PRINCIPAL FINDINGS: Using behavioral measures, we explored the human ability to detect fear and disgust vs. neutral expressions and compared it to the ability to discriminate between genders at eccentricities up to 40°. Responses were faster for the detection of emotion compared to gender. Emotion was detected from fearful faces up to 40° of eccentricity. CONCLUSIONS: Our results demonstrate the human ability to detect facial expressions presented in the far periphery up to 40° of eccentricity. The increasing advantage of emotion compared to gender processing with increasing eccentricity might reflect a major implication of the magnocellular visual pathway in facial expression processing. This advantage may suggest that emotion detection, relative to gender identification, is less impacted by visual acuity and within-face crowding in the periphery. These results are consistent with specific and automatic processing of danger-related information, which may drive attention to those messages and allow for a fast behavioral reaction.

  9. Synthetic vision and memory model for virtual human - biomed 2010.

    Science.gov (United States)

    Zhao, Yue; Kang, Jinsheng; Wright, David

    2010-01-01

    This paper describes the methods and case studies of a novel synthetic vision and memory model for virtual human. The synthetic vision module simulates the biological / optical abilities and limitations of the human vision. The module is based on a series of collision detection between the boundary of virtual humans field of vision (FOV) volume and the surface of objects in a recreated 3D environment. The memory module simulates a short-term memory capability by employing a simplified memory structure (first-in-first-out stack). The synthetic vision and memory model has been integrated into a virtual human modelling project, Intelligent Virtual Modelling. The project aimed to improve the realism and autonomy of virtual humans.

  10. Optical coherent tomography in diagnoses of peripheral retinal degenarations

    OpenAIRE

    O. G. Pozdeyeva; T. B. Shaimov; A. Yu. Galin; R. B. Shaimov; T. A. Shaimova; A. V. Zolotova; A. V. Fomin

    2014-01-01

    Purpose: Studying the capabilities of optical coherence tomography (RTVue-100, OPTOVUE, USA) in evaluation of peripheral retinal degenerations, vitreoretinal adhesions, adjacent vitreous body as well as measurement of morphometric data.Methods: The study included 189 patients (239 eyes) with peripheral retinal degeneration. 77 men and 112 women aged 18 to 84 underwent an ophthalmologic examination since November 2012 until October 2013. The peripheral retina was visualized with the help of op...

  11. Comparing sports vision among three groups of soft tennis adolescent athletes: Normal vision, refractive errors with and without correction

    Directory of Open Access Journals (Sweden)

    Shih-Tsun Chang

    2015-01-01

    Full Text Available Background: The effect of correcting static vision on sports vision is still not clear. Aim: To examine whether sports vision (depth perception [DP], dynamic visual acuity [DVA], eye movement [EM], peripheral vision [PV], and momentary vision [MV], were different among soft tennis adolescent athletes with normal vision (Group A, with refractive error and corrected with (Group B and without eyeglasses (Group C. Setting and Design: A cross-section study was conducted. Soft tennis athletes aged 10–13 who played softball tennis for 2–5 years, and who were without any ocular diseases and without visual training for the past 3 months were recruited. Materials and Methods: DPs were measured in an absolute deviation (mm between a moving rod and fixing rod (approaching at 25 mm/s, receding at 25 mm/s, approaching at 50 mm/s, receding at 50 mm/s using electric DP tester. A smaller deviation represented better DP. DVA, EM, PV, and MV were measured on a scale from 1 (worse to 10 (best using ATHLEVISION software. Statistical Analysis: Chi-square test and Kruskal–Wallis test was used to compare the data among the three study groups. Results: A total of 73 athletes (37 in Group A, 8 in Group B, 28 in Group C were enrolled in this study. All four items of DP showed significant difference among the three study groups (P = 0.0051, 0.0004, 0.0095, 0.0021. PV displayed significant difference among the three study groups (P = 0.0044. There was no significant difference in DVA, EM, and MV among the three study groups. Conclusions: Significant better DP and PV were seen among soft tennis adolescent athletes with normal vision than those with refractive error regardless whether they had eyeglasses corrected. On the other hand, DVA, EM, and MV were similar among the three study groups.

  12. Basic design principles of colorimetric vision systems

    Science.gov (United States)

    Mumzhiu, Alex M.

    1998-10-01

    Color measurement is an important part of overall production quality control in textile, coating, plastics, food, paper and other industries. The color measurement instruments such as colorimeters and spectrophotometers, used for production quality control have many limitations. In many applications they cannot be used for a variety of reasons and have to be replaced with human operators. Machine vision has great potential for color measurement. The components for color machine vision systems, such as broadcast quality 3-CCD cameras, fast and inexpensive PCI frame grabbers, and sophisticated image processing software packages are available. However the machine vision industry has only started to approach the color domain. The few color machine vision systems on the market, produced by the largest machine vision manufacturers have very limited capabilities. A lack of understanding that a vision based color measurement system could fail if it ignores the basic principles of colorimetry is the main reason for the slow progress of color vision systems. the purpose of this paper is to clarify how color measurement principles have to be applied to vision systems and how the electro-optical design features of colorimeters have to be modified in order to implement them for vision systems. The subject of this presentation far exceeds the limitations of a journal paper so only the most important aspects will be discussed. An overview of the major areas of applications for colorimetric vision system will be discussed. Finally, the reasons why some customers are happy with their vision systems and some are not will be analyzed.

  13. Intelligent Vision System for Door Sensing Mobile Robot

    Directory of Open Access Journals (Sweden)

    Jharna Majumdar

    2012-08-01

    Full Text Available Wheeled Mobile Robots find numerous applications in the Indoor man made structured environments. In order to operate effectively, the robots must be capable of sensing its surroundings. Computer Vision is one of the prime research areas directed towards achieving these sensing capabilities. In this paper, we present a Door Sensing Mobile Robot capable of navigating in the indoor environment. A robust and inexpensive approach for recognition and classification of the door, based on monocular vision system helps the mobile robot in decision making. To prove the efficacy of the algorithm we have designed and developed a ‘Differentially’ Driven Mobile Robot. A wall following behavior using Ultra Sonic range sensors is employed by the mobile robot for navigation in the corridors.  Field Programmable Gate Arrays (FPGA have been used for the implementation of PD Controller for wall following and PID Controller to control the speed of the Geared DC Motor.

  14. Visions and visioning in foresight activities

    DEFF Research Database (Denmark)

    Jørgensen, Michael Søgaard; Grosu, Dan

    2007-01-01

    The paper discusses the roles of visioning processes and visions in foresight activities and in societal discourses and changes parallel to or following foresight activities. The overall topic can be characterised as the dynamics and mechanisms that make visions and visioning processes work...... or not work. The theoretical part of the paper presents an actor-network theory approach to the analyses of visions and visioning processes, where the shaping of the visions and the visioning and what has made them work or not work is analysed. The empirical part is based on analyses of the roles of visions...... and visioning processes in a number of foresight processes from different societal contexts. The analyses have been carried out as part of the work in the COST A22 network on foresight. A vision is here understood as a description of a desirable or preferable future, compared to a scenario which is understood...

  15. Foveal Processing Under Concurrent Peripheral Load in Profoundly Deaf Adults

    Science.gov (United States)

    2016-01-01

    Development of the visual system typically proceeds in concert with the development of audition. One result is that the visual system of profoundly deaf individuals differs from that of those with typical auditory systems. While past research has suggested deaf people have enhanced attention in the visual periphery, it is still unclear whether or not this enhancement entails deficits in central vision. Profoundly deaf and typically hearing adults were administered a variant of the useful field of view task that independently assessed performance on concurrent central and peripheral tasks. Identification of a foveated target was impaired by a concurrent selective peripheral attention task, more so in profoundly deaf adults than in the typically hearing. Previous findings of enhanced performance on the peripheral task were not replicated. These data are discussed in terms of flexible allocation of spatial attention targeted towards perceived task demands, and support a modified “division of labor” hypothesis whereby attentional resources co-opted to process peripheral space result in reduced resources in the central visual field. PMID:26657078

  16. Space, place and atmosphere. Emotion and peripherical perception in architectural experience

    Directory of Open Access Journals (Sweden)

    Juhani Pallasmaa

    2014-07-01

    Full Text Available Architectural experiences are essentially multi-sensory and simultaneous, and a complex entity is usually grasped as an atmosphere, ambience or feeling. In fact, the judgement concerning the character of a space or place calls for categories of sensing that extend beyond the five Aristotelian senses, such as the embodied existential sense, and, as a result, the entity is perceived in a diffuse, peripheral and unconscious manner. Paradoxically, we grasp an atmosphere before we have consciously identified its constituent factors and ingredients. «We perceive atmospheres through our emotional sensibility – a form of perception that works incredibly quickly, and which we humans evidently need to help us survive», Peter Zumthor suggests. We are mentally and emotionally affected by works of art before we understand them, or we may not understand them intellectually at all. Sensitive artists and architects intuit experiential and emotive qualities of spaces, places and images. This capacity calls for a specific kind of imagination, an emphatic imagination. Atmospheres are percieved peripherally through diffuse vision interacting with other sense modalities, and they are experienced emotionally rather than intellectually. The studies on the differentiation of the two brain hemispheres suggest that atmospheres are perceived through the right hemisphere. Somewhat surprisingly, atmospheres are more conscious objectives in literature, cinema, theater, painting and music than in architecture, which has been traditionally approached formally and perceived primarily through focused vision. Yet, when we see a thing in focus, we are outsiders to it, whereas the experience of being in a space calls for peripheral and unfocused perception. One of the reasons for the experiential poverty of contemporary settings could be in the poverty of their peripheral stimuli.

  17. Enhanced peripheral visual processing in congenitally deaf humans is supported by multiple brain regions, including primary auditory cortex

    OpenAIRE

    Scott, Gregory D.; Karns, Christina M.; Dow, Mark W.; Stevens, Courtney; Neville, Helen J.

    2014-01-01

    Brain reorganization associated with altered sensory experience clarifies the critical role of neuroplasticity in development. An example is enhanced peripheral visual processing associated with congenital deafness, but the neural systems supporting this have not been fully characterized. A gap in our understanding of deafness-enhanced peripheral vision is the contribution of primary auditory cortex. Previous studies of auditory cortex that use anatomical normalization across participants wer...

  18. A lightweight, inexpensive robotic system for insect vision.

    Science.gov (United States)

    Sabo, Chelsea; Chisholm, Robert; Petterson, Adam; Cope, Alex

    2017-09-01

    Designing hardware for miniaturized robotics which mimics the capabilities of flying insects is of interest, because they share similar constraints (i.e. small size, low weight, and low energy consumption). Research in this area aims to enable robots with similarly efficient flight and cognitive abilities. Visual processing is important to flying insects' impressive flight capabilities, but currently, embodiment of insect-like visual systems is limited by the hardware systems available. Suitable hardware is either prohibitively expensive, difficult to reproduce, cannot accurately simulate insect vision characteristics, and/or is too heavy for small robotic platforms. These limitations hamper the development of platforms for embodiment which in turn hampers the progress on understanding of how biological systems fundamentally work. To address this gap, this paper proposes an inexpensive, lightweight robotic system for modelling insect vision. The system is mounted and tested on a robotic platform for mobile applications, and then the camera and insect vision models are evaluated. We analyse the potential of the system for use in embodiment of higher-level visual processes (i.e. motion detection) and also for development of navigation based on vision for robotics in general. Optic flow from sample camera data is calculated and compared to a perfect, simulated bee world showing an excellent resemblance. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. Evidence Based Medicine in Space Flight: Evaluation of Inflight Vision Data for Operational Decision-Making

    Science.gov (United States)

    Van Baalen, Mary; Mason, Sara; Foy, Millennia; Wear, Mary; Taiym, Wafa; Moynihan, Shannan; Alexander, David; Hart, Steve; Tarver, William

    2015-01-01

    Due to recently identified vision changes associated with space flight, JSC Space and Clinical Operations (SCO) implemented broad mission-related vision testing starting in 2009. Optical Coherence Tomography (OCT), 3 Tesla Brain and Orbit MRIs, Optical Biometry were implemented terrestrially for clinical monitoring. While no inflight vision testing was in place, already available onorbit technology was leveraged to facilitate in-flight clinical monitoring, including visual acuity, Amsler grid, tonometry, and ultrasonography. In 2013, on-orbit testing capabilities were expanded to include contrast sensitivity testing and OCT. As these additional testing capabilities have been added, resource prioritization, particularly crew time, is under evaluation.

  20. Robotics Vision-based Heuristic Reasoning for Underwater Target Tracking and Navigation

    Directory of Open Access Journals (Sweden)

    Chua Kia

    2005-09-01

    Full Text Available This paper presents a robotics vision-based heuristic reasoning system for underwater target tracking and navigation. This system is introduced to improve the level of automation of underwater Remote Operated Vehicles (ROVs operations. A prototype which combines computer vision with an underwater robotics system is successfully designed and developed to perform target tracking and intelligent navigation. This study focuses on developing image processing algorithms and fuzzy inference system for the analysis of the terrain. The vision system developed is capable of interpreting underwater scene by extracting subjective uncertainties of the object of interest. Subjective uncertainties are further processed as multiple inputs of a fuzzy inference system that is capable of making crisp decisions concerning where to navigate. The important part of the image analysis is morphological filtering. The applications focus on binary images with the extension of gray-level concepts. An open-loop fuzzy control system is developed for classifying the traverse of terrain. The great achievement is the system's capability to recognize and perform target tracking of the object of interest (pipeline in perspective view based on perceived condition. The effectiveness of this approach is demonstrated by computer and prototype simulations. This work is originated from the desire to develop robotics vision system with the ability to mimic the human expert's judgement and reasoning when maneuvering ROV in the traverse of the underwater terrain.

  1. Robotics Vision-based Heuristic Reasoning for Underwater Target Tracking and Navigation

    Directory of Open Access Journals (Sweden)

    Chua Kia

    2008-11-01

    Full Text Available This paper presents a robotics vision-based heuristic reasoning system for underwater target tracking and navigation. This system is introduced to improve the level of automation of underwater Remote Operated Vehicles (ROVs operations. A prototype which combines computer vision with an underwater robotics system is successfully designed and developed to perform target tracking and intelligent navigation. This study focuses on developing image processing algorithms and fuzzy inference system for the analysis of the terrain. The vision system developed is capable of interpreting underwater scene by extracting subjective uncertainties of the object of interest. Subjective uncertainties are further processed as multiple inputs of a fuzzy inference system that is capable of making crisp decisions concerning where to navigate. The important part of the image analysis is morphological filtering. The applications focus on binary images with the extension of gray-level concepts. An open-loop fuzzy control system is developed for classifying the traverse of terrain. The great achievement is the system's capability to recognize and perform target tracking of the object of interest (pipeline in perspective view based on perceived condition. The effectiveness of this approach is demonstrated by computer and prototype simulations. This work is originated from the desire to develop robotics vision system with the ability to mimic the human expert's judgement and reasoning when maneuvering ROV in the traverse of the underwater terrain.

  2. ASCI's Vision for supercomputing future

    International Nuclear Information System (INIS)

    Nowak, N.D.

    2003-01-01

    The full text of publication follows. Advanced Simulation and Computing (ASC, formerly Accelerated Strategic Computing Initiative [ASCI]) was established in 1995 to help Defense Programs shift from test-based confidence to simulation-based confidence. Specifically, ASC is a focused and balanced program that is accelerating the development of simulation capabilities needed to analyze and predict the performance, safety, and reliability of nuclear weapons and certify their functionality - far exceeding what might have been achieved in the absence of a focused initiative. To realize its vision, ASC is creating simulation and proto-typing capabilities, based on advanced weapon codes and high-performance computing

  3. A memory-array architecture for computer vision

    Energy Technology Data Exchange (ETDEWEB)

    Balsara, P.T.

    1989-01-01

    With the fast advances in the area of computer vision and robotics there is a growing need for machines that can understand images at a very high speed. A conventional von Neumann computer is not suited for this purpose because it takes a tremendous amount of time to solve most typical image processing problems. Exploiting the inherent parallelism present in various vision tasks can significantly reduce the processing time. Fortunately, parallelism is increasingly affordable as hardware gets cheaper. Thus it is now imperative to study computer vision in a parallel processing framework. The author should first design a computational structure which is well suited for a wide range of vision tasks and then develop parallel algorithms which can run efficiently on this structure. Recent advances in VLSI technology have led to several proposals for parallel architectures for computer vision. In this thesis he demonstrates that a memory array architecture with efficient local and global communication capabilities can be used for high speed execution of a wide range of computer vision tasks. This architecture, called the Access Constrained Memory Array Architecture (ACMAA), is efficient for VLSI implementation because of its modular structure, simple interconnect and limited global control. Several parallel vision algorithms have been designed for this architecture. The choice of vision problems demonstrates the versatility of ACMAA for a wide range of vision tasks. These algorithms were simulated on a high level ACMAA simulator running on the Intel iPSC/2 hypercube, a parallel architecture. The results of this simulation are compared with those of sequential algorithms running on a single hypercube node. Details of the ACMAA processor architecture are also presented.

  4. Immediate and intermediate-term results of optical coherence tomography guided atherectomy in the treatment of peripheral arterial disease: Initial results from the VISION trial

    International Nuclear Information System (INIS)

    Cawich, Ian; Paixao, Andre R.M.; Marmagkiolis, Konstantinos; Lendel, Vasili; Rodriguez-Araujo, Gerardo; Rollefson, William A.; Mego, David M.; Cilingiroglu, Mehmet

    2016-01-01

    Background: Long-term patency rates for percutaneous peripheral arterial interventions are suboptimal. Optical coherence tomography (OCT) guided atherectomy may yield superior patency by optimizing plaque removal while preserving the tunica media and adventitia. Methods: The VISION study is a multicenter prospective study of patients with peripheral arterial disease undergoing OCT guided atherectomy with the Pantheris™ device. In 11 patients enrolled in a single center, we report procedural and clinical outcomes, at 30 days and 6 months. Results: The mean age was 63 ± 11 years and 73% (n = 8) were men. The target lesion was in the superficial femoral artery in 82% (n = 9) of the patients. Mean stenosis severity was 87% ± 10% and mean lesion length was 39 ± 31 mm. Procedural success was observed in all patients with no device related complications. Mean post-atherectomy stenosis was 18% ± 15%. Almost all excised tissue consisted of intimal plaque (94%). At 30 days, significant improvements in Rutherford class, VascuQoL scores and ABI were observed, 0.9 ± 0.8 vs. 3.1 ± 0.7 (p = 0.01), 4.9 ± 1.9 vs. 3.6 ± 1.5 (p = 0.03) and 1.04 ± 0.19 vs. 0.80 ± 0.19 (p < 0.01) respectively. At 6 months, there were significant improvements in Rutherford class (1.0 ± 1.0 vs. 3.1 ± 0.7, p = 0.01) and ABI (0.93 ± 0.19 versus 0.80 ± 0.19, p = 0.02) but not in VascuQoL scores (3.7 ± 1.4 versus 3.6 ± 1.5, p = 0.48). Target lesion revascularization occurred in 18% (n = 2) of the patients. Conclusion: OCT guided atherectomy resulted in high procedural success, no device related complications and encouraging results up to 6 months. Histological analysis suggested little injury to the media and adventitia. Larger studies are needed to confirm the efficacy of this approach. - Highlights: • OCT- guided atherectomy may yield superior patency by optimizing plaque removal and preserving the tunica media and adventitia. • OCT guided atherectomy resulted in high procedural

  5. Immediate and intermediate-term results of optical coherence tomography guided atherectomy in the treatment of peripheral arterial disease: Initial results from the VISION trial

    Energy Technology Data Exchange (ETDEWEB)

    Cawich, Ian; Paixao, Andre R.M. [Arkansas Heart Hospital, Peripheral Vascular Institute, Little Rock, AR (United States); Marmagkiolis, Konstantinos [Citizens Memorial Heart and Vascular Institute, Bolivar, MO (United States); University of Missouri, Columbia, MO (United States); Lendel, Vasili; Rodriguez-Araujo, Gerardo; Rollefson, William A.; Mego, David M. [Arkansas Heart Hospital, Peripheral Vascular Institute, Little Rock, AR (United States); Cilingiroglu, Mehmet, E-mail: Cilingiroglumehmet@gmail.com [Arkansas Heart Hospital, Peripheral Vascular Institute, Little Rock, AR (United States); Koc University, School of Medicine, Istanbul (Turkey)

    2016-10-15

    Background: Long-term patency rates for percutaneous peripheral arterial interventions are suboptimal. Optical coherence tomography (OCT) guided atherectomy may yield superior patency by optimizing plaque removal while preserving the tunica media and adventitia. Methods: The VISION study is a multicenter prospective study of patients with peripheral arterial disease undergoing OCT guided atherectomy with the Pantheris™ device. In 11 patients enrolled in a single center, we report procedural and clinical outcomes, at 30 days and 6 months. Results: The mean age was 63 ± 11 years and 73% (n = 8) were men. The target lesion was in the superficial femoral artery in 82% (n = 9) of the patients. Mean stenosis severity was 87% ± 10% and mean lesion length was 39 ± 31 mm. Procedural success was observed in all patients with no device related complications. Mean post-atherectomy stenosis was 18% ± 15%. Almost all excised tissue consisted of intimal plaque (94%). At 30 days, significant improvements in Rutherford class, VascuQoL scores and ABI were observed, 0.9 ± 0.8 vs. 3.1 ± 0.7 (p = 0.01), 4.9 ± 1.9 vs. 3.6 ± 1.5 (p = 0.03) and 1.04 ± 0.19 vs. 0.80 ± 0.19 (p < 0.01) respectively. At 6 months, there were significant improvements in Rutherford class (1.0 ± 1.0 vs. 3.1 ± 0.7, p = 0.01) and ABI (0.93 ± 0.19 versus 0.80 ± 0.19, p = 0.02) but not in VascuQoL scores (3.7 ± 1.4 versus 3.6 ± 1.5, p = 0.48). Target lesion revascularization occurred in 18% (n = 2) of the patients. Conclusion: OCT guided atherectomy resulted in high procedural success, no device related complications and encouraging results up to 6 months. Histological analysis suggested little injury to the media and adventitia. Larger studies are needed to confirm the efficacy of this approach. - Highlights: • OCT- guided atherectomy may yield superior patency by optimizing plaque removal and preserving the tunica media and adventitia. • OCT guided atherectomy resulted in high procedural

  6. Mechanism of supply chain coordination cased on dynamic capability framework-the mediating role of manufacturing capabilities

    Directory of Open Access Journals (Sweden)

    Tiantian Gao

    2014-10-01

    Full Text Available Purpose: A critical issue has been absent from the conversation on supply chain coordination: how supply chain coordination influence the enterprise performance. This research proposes a new vision to research the performance mechanism of supply chain coordination capability as a dynamic capability. Manufacturing capabilities are existed as mediating role. Design/methodology/approach: Data from International Manufacturing Strategy Survey in 2009 is used to verify the mediating model by hierarchical regression analysis. Findings: The results show that supply chain coordination impacts the enterprise performance positively and indirect impacts the enterprise performance through quality, cost, flexibility. Research implications: This study presents an overview of the impact of supply chain coordination and manufacturing capabilities on enterprise performance, giving grasp for further research of the relationships that exist between them. Originality/value: This finding integrates insights from previous research in dynamic capability framework and supply chain management into a generalization and extension of the performance mechanism in manufacturing enterprises.

  7. Immediate and intermediate-term results of optical coherence tomography guided atherectomy in the treatment of peripheral arterial disease: Initial results from the VISION trial.

    Science.gov (United States)

    Cawich, Ian; Paixao, Andre R M; Marmagkiolis, Konstantinos; Lendel, Vasili; Rodriguez-Araujo, Gerardo; Rollefson, William A; Mego, David M; Cilingiroglu, Mehmet

    Long-term patency rates for percutaneous peripheral arterial interventions are suboptimal. Optical coherence tomography (OCT) guided atherectomy may yield superior patency by optimizing plaque removal while preserving the tunica media and adventitia. The VISION study is a multicenter prospective study of patients with peripheral arterial disease undergoing OCT guided atherectomy with the Pantheris™ device. In 11 patients enrolled in a single center, we report procedural and clinical outcomes, at 30days and 6months. The mean age was 63±11years and 73% (n=8) were men. The target lesion was in the superficial femoral artery in 82% (n=9) of the patients. Mean stenosis severity was 87%±10% and mean lesion length was 39±31mm. Procedural success was observed in all patients with no device related complications. Mean post-atherectomy stenosis was 18%±15%. Almost all excised tissue consisted of intimal plaque (94%). At 30days, significant improvements in Rutherford class, VascuQoL scores and ABI were observed, 0.9±0.8 vs. 3.1±0.7 (p=0.01), 4.9±1.9 vs. 3.6±1.5 (p=0.03) and 1.04±0.19 vs. 0.80±0.19 (patherectomy resulted in high procedural success, no device related complications and encouraging results up to 6months. Histological analysis suggested little injury to the media and adventitia. Larger studies are needed to confirm the efficacy of this approach. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Human-Centered Design Capability

    Science.gov (United States)

    Fitts, David J.; Howard, Robert

    2009-01-01

    For NASA, human-centered design (HCD) seeks opportunities to mitigate the challenges of living and working in space in order to enhance human productivity and well-being. Direct design participation during the development stage is difficult, however, during project formulation, a HCD approach can lead to better more cost-effective products. HCD can also help a program enter the development stage with a clear vision for product acquisition. HCD tools for clarifying design intent are listed. To infuse HCD into the spaceflight lifecycle the Space and Life Sciences Directorate developed the Habitability Design Center. The Center has collaborated successfully with program and project design teams and with JSC's Engineering Directorate. This presentation discusses HCD capabilities and depicts the Center's design examples and capabilities.

  9. Influence of anaerobic physical effort in the horizontal and vertical peripheral view INFLUENCIA DEL ESFUERZO FÍSICO ANAERÓBICO EN LA VISIÓN PERIFÉRICA VERTICAL Y HORIZONTAL

    Directory of Open Access Journals (Sweden)

    M. Arteaga

    2010-09-01

    Full Text Available

    There now seems to be a generalized tendency to consider that sporting performance declines as the sportsperson becomes fatigued. However, there is little empirical evidence to show that this adversely affects visual function. In some sports it is necessary to see stimuli in zones peripheral to central vision. The aim of this study is to analyze the influence of anaerobic exertion on vertical and horizontal Peripheral Vision. An intra-subject design was used with 14 replications. The visual parameters of Vertical Peripheral Vision and Horizontal Peripheral Vision were measured in different fatigue conditions to analyze the possible negative influence which this could exert on the subject’s visual capacity. The results show that fatigue due to anaerobic effort does not harm the visual abilities studied.
    KEY WORDS: Peripheral Vision, Fatigue, Anaerobic exertion, Visual abilities

    Parece haber una tendencia generalizada a considerar que el rendimiento deportivo disminuye en la medida en que los deportistas acumulan fatiga; sin embargo existen pocas evidencias empíricas que indiquen que la función visual se vea perjudicada por este motivo. En algunos deportes es necesario observar estímulos en zonas periféricas a la visión central. En el presente estudio se pretende analizar la influencia de los esfuerzos anaeeróbicos sobre la Visión Periférica (vertical y horizontal. Se utilizó un diseño intrasujeto A-(B1,B2-A con catorce replicaciones. Se realizaron mediciones de los parámetros visuales: Visión Periférica Vertical y Visión Periférica Horizontal en diferentes condiciones de fatiga para analizar la posible influencia negativa que pudiera ejercer ésta sobre la capacidad visual de los sujetos. Los resultados permiten afirmar que la fatiga debida a esfuerzos de tipo anaeróbico no producen un perjuicio sobre las habilidades visuales estudiadas.
    PALABRAS CLAVE: Visi

  10. Vision in high-level football officials.

    Science.gov (United States)

    Baptista, António Manuel Gonçalves; Serra, Pedro M; McAlinden, Colm; Barrett, Brendan T

    2017-01-01

    Officiating in football depends, at least to some extent, upon adequate visual function. However, there is no vision standard for football officiating and the nature of the relationship between officiating performance and level of vision is unknown. As a first step in characterising this relationship, we report on the clinically-measured vision and on the perceived level of vision in elite-level, Portuguese football officials. Seventy-one referees (R) and assistant referees (AR) participated in the study, representing 92% of the total population of elite level football officials in Portugal in the 2013/2014 season. Nine of the 22 Rs (40.9%) and ten of the 49 ARs (20.4%) were international-level. Information about visual history was also gathered. Perceived vision was assessed using the preference-values-assigned-to-global-visual-status (PVVS) and the Quality-of-Vision (QoV) questionnaire. Standard clinical vision measures (including visual acuity, contrast sensitivity and stereopsis) were gathered in a subset (n = 44, 62%) of the participants. Data were analysed according to the type (R/AR) and level (international/national) of official, and Bonferroni corrections were applied to reduce the risk of type I errors. Adopting criterion for statistical significance of pfootball officials were similar to published normative values for young, adult populations and similar between R and AR. Clinically-measured vision did not differ according to officiating level. Visual acuity measured with and without a pinhole disc indicated that around one quarter of participants may be capable of better vision when officiating, as evidenced by better acuity (≥1 line of letters) using the pinhole. Amongst the clinical visual tests we used, we did not find evidence for above-average performance in elite-level football officials. Although the impact of uncorrected mild to moderate refractive error upon officiating performance is unknown, with a greater uptake of eye examinations, visual

  11. Remote-controlled vision-guided mobile robot system

    Science.gov (United States)

    Ande, Raymond; Samu, Tayib; Hall, Ernest L.

    1997-09-01

    Automated guided vehicles (AGVs) have many potential applications in manufacturing, medicine, space and defense. The purpose of this paper is to describe exploratory research on the design of the remote controlled emergency stop and vision systems for an autonomous mobile robot. The remote control provides human supervision and emergency stop capabilities for the autonomous vehicle. The vision guidance provides automatic operation. A mobile robot test-bed has been constructed using a golf cart base. The mobile robot (Bearcat) was built for the Association for Unmanned Vehicle Systems (AUVS) 1997 competition. The mobile robot has full speed control with guidance provided by a vision system and an obstacle avoidance system using ultrasonic sensors systems. Vision guidance is accomplished using two CCD cameras with zoom lenses. The vision data is processed by a high speed tracking device, communicating with the computer the X, Y coordinates of blobs along the lane markers. The system also has three emergency stop switches and a remote controlled emergency stop switch that can disable the traction motor and set the brake. Testing of these systems has been done in the lab as well as on an outside test track with positive results that show that at five mph the vehicle can follow a line and at the same time avoid obstacles.

  12. Vision Assessment and Prescription of Low Vision Devices

    OpenAIRE

    Keeffe, Jill

    2004-01-01

    Assessment of vision and prescription of low vision devices are part of a comprehensive low vision service. Other components of the service include training the person affected by low vision in use of vision and other senses, mobility, activities of daily living, and support for education, employment or leisure activities. Specialist vision rehabilitation agencies have services to provide access to information (libraries) and activity centres for groups of people with impaired vision.

  13. Development of embedded real-time and high-speed vision platform

    Science.gov (United States)

    Ouyang, Zhenxing; Dong, Yimin; Yang, Hua

    2015-12-01

    Currently, high-speed vision platforms are widely used in many applications, such as robotics and automation industry. However, a personal computer (PC) whose over-large size is not suitable and applicable in compact systems is an indispensable component for human-computer interaction in traditional high-speed vision platforms. Therefore, this paper develops an embedded real-time and high-speed vision platform, ER-HVP Vision which is able to work completely out of PC. In this new platform, an embedded CPU-based board is designed as substitution for PC and a DSP and FPGA board is developed for implementing image parallel algorithms in FPGA and image sequential algorithms in DSP. Hence, the capability of ER-HVP Vision with size of 320mm x 250mm x 87mm can be presented in more compact condition. Experimental results are also given to indicate that the real-time detection and counting of the moving target at a frame rate of 200 fps at 512 x 512 pixels under the operation of this newly developed vision platform are feasible.

  14. An Uncommon Ocular Finding in Behçet’s Disease: Peripheral Ulcerative Keratitis

    Directory of Open Access Journals (Sweden)

    Orhan Ayar

    2014-12-01

    Full Text Available A 43-year-old female patient presented to our eye clinic with blurred vision and redness in the right eye for 2 weeks. Biomicroscopic examination revealed peripheral ulcerative keratitis with corneal thinning. After prescribing topical fluorometholon, moxifloxacin, preservative-free artificial tears, and vitamin A ointment, the patient was referred to Rheumatology department. Based on clinical findings and systemic research, the diagnosis of Behçet’s disease was established, and oral systemic azathioprine, hydroxychloroquine, and prednisolone treatment was started. In this study, we presented a case of peripheral ulcerative keratitis, an ocular manifestation uncommonly seen in Behçet’s disease. (Turk J Ophthalmol 2014; 44: 484-5

  15. Laser peripheral iridoplasty for angle-closure.

    Science.gov (United States)

    Ng, Wai Siene; Ang, Ghee Soon; Azuara-Blanco, Augusto

    2012-02-15

    Angle-closure glaucoma is a leading cause of irreversible blindness in the world. Treatment is aimed at opening the anterior chamber angle and lowering the IOP with medical and/or surgical treatment (e.g. trabeculectomy, lens extraction). Laser iridotomy works by eliminating pupillary block and widens the anterior chamber angle in the majority of patients. When laser iridotomy fails to open the anterior chamber angle, laser iridoplasty may be recommended as one of the options in current standard treatment for angle-closure. Laser peripheral iridoplasty works by shrinking and pulling the peripheral iris tissue away from the trabecular meshwork. Laser peripheral iridoplasty can be used for crisis of acute angle-closure and also in non-acute situations.   To assess the effectiveness of laser peripheral iridoplasty in the treatment of narrow angles (i.e. primary angle-closure suspect), primary angle-closure (PAC) or primary angle-closure glaucoma (PACG) in non-acute situations when compared with any other intervention. In this review, angle-closure will refer to patients with narrow angles (PACs), PAC and PACG. We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2011, Issue 12), MEDLINE (January 1950 to January 2012), EMBASE (January 1980 to January 2012), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to January 2012), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). There were no date or language restrictions in the electronic searches for trials. The electronic databases were last searched on 5 January 2012. We included only randomised controlled trials (RCTs) in this review. Patients with narrow angles, PAC or PACG were eligible. We excluded studies that included only patients with acute presentations

  16. Antecedents of network capability and their effects on innovation performance: an empirical test of hi-tech firms in China

    NARCIS (Netherlands)

    Fang, Gang; Ma, Xiang Yuan; Brouwers-Ren, Liqin; Zhou, Qing

    2014-01-01

    A firm’s competitive advantage can come not only from internal resources but also from inter-firm innovation networks. This paper shows that network capabilities (i.e., network visioning capability, network constructing capability, network operating capability and network centring capability) are

  17. Information architecture. Volume 4: Vision

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    The Vision document marks the transition from definition to implementation of the Department of Energy (DOE) Information Architecture Program. A description of the possibilities for the future, supported by actual experience with a process model and tool set, points toward implementation options. The directions for future information technology investments are discussed. Practical examples of how technology answers the business and information needs of the organization through coordinated and meshed data, applications, and technology architectures are related. This document is the fourth and final volume in the planned series for defining and exhibiting the DOE information architecture. The targeted scope of this document includes DOE Program Offices, field sites, contractor-operated facilities, and laboratories. This document paints a picture of how, over the next 7 years, technology may be implemented, dramatically improving the ways business is conducted at DOE. While technology is mentioned throughout this document, the vision is not about technology. The vision concerns the transition afforded by technology and the process steps to be completed to ensure alignment with business needs. This goal can be met if those directing the changing business and mission-support processes understand the capabilities afforded by architectural processes.

  18. Comparing the relative peripheral refraction effect of single vision and multifocal contact lenses measured using an autorefractor and an aberrometer: A pilot study.

    Science.gov (United States)

    Bakaraju, Ravi C; Fedtke, Cathleen; Ehrmann, Klaus; Ho, Arthur

    2015-01-01

    To compare the contributions of single vision (SVCL) and multifocal contact lenses (MFCL) to the relative peripheral refraction (RPR) profiles obtained via an autorefractor and an aberrometer in a pilot study. Two instruments, Shin-Nippon NVision K5001 (SN) and COAS-HD, were modified to permit open field PR measurements. Two myopic adults (CF, RB) were refracted (cycloplegia) under eight conditions: baseline (no CL); three SVCLs: Focus Dailies(®) (Alcon, USA), PureVision(®) (Bausch & Lomb, USA) and AirOptix(®) (Alcon, USA); and four MFCLs: AirOptix(®) (Alcon, USA), Proclear(®) Distant and Near (Cooper Vision, USA), and PureVision(®) (Bausch & Lomb, USA). CLs had a distance prescription of -2.00D and for MFCLs, a +2.50D Add was selected. Five independent measurements were performed at field angles from -40° to +40° in 10° increments with both instruments. The COAS-HD measures were analyzed at 3mm pupil diameter. Results are reported as a change in the relative PR profile, as refractive power vector components: M, J180, and J45. Overall, at baseline, M, J180 and J45 measures obtained with SN and COAS-HD were considerably different only for field angles ≥±30°, which agreed well with previous studies. With respect to M, this observation held true for most SVCLs with a few exceptions. The J180 measures obtained with COAS-HD were considerably greater in magnitude than those acquired with SN. For SVCLs, the greatest difference was found at -40° for AirOptix SV (ΔCF=3.20D, ΔRB=1.56D) and for MFCLs it was for Proclear Distance at -40° (ΔCF=2.58D, ΔRB=1.39D). The J45 measures obtained with SN were noticeably different to the respective measures with COAS-HD, both in magnitude and sign. The greatest difference was found with AirOptix Multifocal in subject RB at -40°, where the COAS-HD measurement was 1.50D more positive. In some cases, the difference in the RPR profiles observed between subjects appeared to be associated with CL decentration. For most test

  19. Latency in Visionic Systems: Test Methods and Requirements

    Science.gov (United States)

    Bailey, Randall E.; Arthur, J. J., III; Williams, Steven P.; Kramer, Lynda J.

    2005-01-01

    A visionics device creates a pictorial representation of the external scene for the pilot. The ultimate objective of these systems may be to electronically generate a form of Visual Meteorological Conditions (VMC) to eliminate weather or time-of-day as an operational constraint and provide enhancement over actual visual conditions where eye-limiting resolution may be a limiting factor. Empirical evidence has shown that the total system delays or latencies including the imaging sensors and display systems, can critically degrade their utility, usability, and acceptability. Definitions and measurement techniques are offered herein as common test and evaluation methods for latency testing in visionics device applications. Based upon available data, very different latency requirements are indicated based upon the piloting task, the role in which the visionics device is used in this task, and the characteristics of the visionics cockpit display device including its resolution, field-of-regard, and field-of-view. The least stringent latency requirements will involve Head-Up Display (HUD) applications, where the visionics imagery provides situational information as a supplement to symbology guidance and command information. Conversely, the visionics system latency requirement for a large field-of-view Head-Worn Display application, providing a Virtual-VMC capability from which the pilot will derive visual guidance, will be the most stringent, having a value as low as 20 msec.

  20. Cities and Climate - What Visions?

    International Nuclear Information System (INIS)

    Haentjens, Jean

    2015-01-01

    Given the difficulty of achieving a global agreement to cope with the challenges of climate change or even a national resilience programme, an increasing number of initiatives are coming up from the local level for preemptively implementing policies to adapt to climate change or combat it. There are several towns and cities across the world that have taken this line (Copenhagen, Totnes, Vaexjoe, Bristol, etc.) but, as Jean Haentjens shows here, an effective response to climate change requires the development of a genuine strategic vision capable of mobilizing all the actors concerned. For the moment, the towns and cities that have managed to come up with such a vision are few and far between. After a -largely historical- review of the importance of vision in changes of urban paradigm, Jean Haentjens stresses how much twenty-first century eco-urbanism broadens the range of possible solutions to the many issues facing our towns and cities today. But, though digital innovations in fact offer new opportunities at the local level, we should nonetheless be wary of 'technological solutionism': the new technologies are tools which towns and cities can use to their advantage, but to become really 'smart' they have to develop a vision. After presenting a series of established or emerging urban models (the frugal city, the creative city, the leisure city and the eco-metropolis), along with the values and imaginative conceptions that underpin them, this article shows - without being unaware of the potential obstacles - how a town or city can produce and renew its strategic vision to reinvent itself and meet the challenges of today

  1. The Advanced Modeling, Simulation and Analysis Capability Roadmap Vision for Engineering

    Science.gov (United States)

    Zang, Thomas; Lieber, Mike; Norton, Charles; Fucik, Karen

    2006-01-01

    This paper summarizes a subset of the Advanced Modeling Simulation and Analysis (AMSA) Capability Roadmap that was developed for NASA in 2005. The AMSA Capability Roadmap Team was chartered to "To identify what is needed to enhance NASA's capabilities to produce leading-edge exploration and science missions by improving engineering system development, operations, and science understanding through broad application of advanced modeling, simulation and analysis techniques." The AMSA roadmap stressed the need for integration, not just within the science, engineering and operations domains themselves, but also across these domains. Here we discuss the roadmap element pertaining to integration within the engineering domain, with a particular focus on implications for future observatory missions. The AMSA products supporting the system engineering function are mission information, bounds on information quality, and system validation guidance. The Engineering roadmap element contains 5 sub-elements: (1) Large-Scale Systems Models, (2) Anomalous Behavior Models, (3) advanced Uncertainty Models, (4) Virtual Testing Models, and (5) space-based Robotics Manufacture and Servicing Models.

  2. Computer vision for automatic inspection of agricultural produce

    Science.gov (United States)

    Molto, Enrique; Blasco, Jose; Benlloch, Jose V.

    1999-01-01

    Fruit and vegetables suffer different manipulations from the field to the final consumer. These are basically oriented towards the cleaning and selection of the product in homogeneous categories. For this reason, several research projects, aimed at fast, adequate produce sorting and quality control are currently under development around the world. Moreover, it is possible to find manual and semi- automatic commercial system capable of reasonably performing these tasks.However, in many cases, their accuracy is incompatible with current European market demands, which are constantly increasing. IVIA, the Valencian Research Institute of Agriculture, located in Spain, has been involved in several European projects related with machine vision for real-time inspection of various agricultural produces. This paper will focus on the work related with two products that have different requirements: fruit and olives. In the case of fruit, the Institute has developed a vision system capable of providing assessment of the external quality of single fruit to a robot that also receives information from other senors. The system use four different views of each fruit and has been tested on peaches, apples and citrus. Processing time of each image is under 500 ms using a conventional PC. The system provides information about primary and secondary color, blemishes and their extension, and stem presence and position, which allows further automatic orientation of the fruit in the final box using a robotic manipulator. Work carried out in olives was devoted to fast sorting of olives for consumption at table. A prototype has been developed to demonstrate the feasibility of a machine vision system capable of automatically sorting 2500 kg/h olives using low-cost conventional hardware.

  3. Artificial vision support system (AVS(2)) for improved prosthetic vision.

    Science.gov (United States)

    Fink, Wolfgang; Tarbell, Mark A

    2014-11-01

    State-of-the-art and upcoming camera-driven, implanted artificial vision systems provide only tens to hundreds of electrodes, affording only limited visual perception for blind subjects. Therefore, real time image processing is crucial to enhance and optimize this limited perception. Since tens or hundreds of pixels/electrodes allow only for a very crude approximation of the typically megapixel optical resolution of the external camera image feed, the preservation and enhancement of contrast differences and transitions, such as edges, are especially important compared to picture details such as object texture. An Artificial Vision Support System (AVS(2)) is devised that displays the captured video stream in a pixelation conforming to the dimension of the epi-retinal implant electrode array. AVS(2), using efficient image processing modules, modifies the captured video stream in real time, enhancing 'present but hidden' objects to overcome inadequacies or extremes in the camera imagery. As a result, visual prosthesis carriers may now be able to discern such objects in their 'field-of-view', thus enabling mobility in environments that would otherwise be too hazardous to navigate. The image processing modules can be engaged repeatedly in a user-defined order, which is a unique capability. AVS(2) is directly applicable to any artificial vision system that is based on an imaging modality (video, infrared, sound, ultrasound, microwave, radar, etc.) as the first step in the stimulation/processing cascade, such as: retinal implants (i.e. epi-retinal, sub-retinal, suprachoroidal), optic nerve implants, cortical implants, electric tongue stimulators, or tactile stimulators.

  4. Low Vision

    Science.gov (United States)

    ... USAJobs Home » Statistics and Data » Low Vision Listen Low Vision Low Vision Defined: Low Vision is defined as the best- ... Ethnicity 2010 U.S. Age-Specific Prevalence Rates for Low Vision by Age, and Race/Ethnicity Table for 2010 ...

  5. Directed Motivational Currents: Using vision to create effective motivational pathways

    Directory of Open Access Journals (Sweden)

    Christine Muir

    2013-10-01

    Full Text Available Vision, that is, the mental representation of the sensory experience of a future goal state (involving imagination and imagery, is currently at the forefront of motivational innovation, and in recent years it has been seen increasingly more often in the motivational tool kit of practicing language teachers. Theories such as Dörnyei’s L2 motivational self system have explored the power that creating effective visions can harness (see, e.g., Dörnyei & Kubanyiova, 2014 and when viewed in conjunction with other current research avenues, such as future time perspective and dynamic systems theory, vision offers exciting potential. A Directed Motivational Current is a new motivational construct that we suggest is capable of integrating many current theoretical strands with vision: It can be described as a motivational drive which energises long-term, sustained behaviour (such as language learning, and through placing vision and goals as critical central components within this construct, it offers real and practical motivational potential. In this conceptual paper, we first discuss current understandings of vision and of Directed Motivational Currents, and then analyse how they may be optimally integrated and employed to create effective motivational pathways in language learning environments.

  6. A Neuromorphic Approach for Tracking using Dynamic Neural Fields on a Programmable Vision-chip

    OpenAIRE

    Martel Julien N.P.; Sandamirskaya Yulia

    2016-01-01

    In artificial vision applications, such as tracking, a large amount of data captured by sensors is transferred to processors to extract information relevant for the task at hand. Smart vision sensors offer a means to reduce the computational burden of visual processing pipelines by placing more processing capabilities next to the sensor. In this work, we use a vision-chip in which a small processor with memory is located next to each photosensitive element. The architecture of this device is ...

  7. Reconfigurable On-Board Vision Processing for Small Autonomous Vehicles

    Directory of Open Access Journals (Sweden)

    James K. Archibald

    2006-12-01

    Full Text Available This paper addresses the challenge of supporting real-time vision processing on-board small autonomous vehicles. Local vision gives increased autonomous capability, but it requires substantial computing power that is difficult to provide given the severe constraints of small size and battery-powered operation. We describe a custom FPGA-based circuit board designed to support research in the development of algorithms for image-directed navigation and control. We show that the FPGA approach supports real-time vision algorithms by describing the implementation of an algorithm to construct a three-dimensional (3D map of the environment surrounding a small mobile robot. We show that FPGAs are well suited for systems that must be flexible and deliver high levels of performance, especially in embedded settings where space and power are significant concerns.

  8. Reconfigurable On-Board Vision Processing for Small Autonomous Vehicles

    Directory of Open Access Journals (Sweden)

    Fife WadeS

    2007-01-01

    Full Text Available This paper addresses the challenge of supporting real-time vision processing on-board small autonomous vehicles. Local vision gives increased autonomous capability, but it requires substantial computing power that is difficult to provide given the severe constraints of small size and battery-powered operation. We describe a custom FPGA-based circuit board designed to support research in the development of algorithms for image-directed navigation and control. We show that the FPGA approach supports real-time vision algorithms by describing the implementation of an algorithm to construct a three-dimensional (3D map of the environment surrounding a small mobile robot. We show that FPGAs are well suited for systems that must be flexible and deliver high levels of performance, especially in embedded settings where space and power are significant concerns.

  9. CFD Vision 2030 Study: A Path to Revolutionary Computational Aerosciences

    Science.gov (United States)

    Slotnick, Jeffrey; Khodadoust, Abdollah; Alonso, Juan; Darmofal, David; Gropp, William; Lurie, Elizabeth; Mavriplis, Dimitri

    2014-01-01

    This report documents the results of a study to address the long range, strategic planning required by NASA's Revolutionary Computational Aerosciences (RCA) program in the area of computational fluid dynamics (CFD), including future software and hardware requirements for High Performance Computing (HPC). Specifically, the "Vision 2030" CFD study is to provide a knowledge-based forecast of the future computational capabilities required for turbulent, transitional, and reacting flow simulations across a broad Mach number regime, and to lay the foundation for the development of a future framework and/or environment where physics-based, accurate predictions of complex turbulent flows, including flow separation, can be accomplished routinely and efficiently in cooperation with other physics-based simulations to enable multi-physics analysis and design. Specific technical requirements from the aerospace industrial and scientific communities were obtained to determine critical capability gaps, anticipated technical challenges, and impediments to achieving the target CFD capability in 2030. A preliminary development plan and roadmap were created to help focus investments in technology development to help achieve the CFD vision in 2030.

  10. Detecting peripheral-based attacks on the host memory

    CERN Document Server

    Stewin, Patrick

    2015-01-01

    This work addresses stealthy peripheral-based attacks on host computers and presents a new approach to detecting them. Peripherals can be regarded as separate systems that have a dedicated processor and dedicated runtime memory to handle their tasks. The book addresses the problem that peripherals generally communicate with the host via the host’s main memory, storing cryptographic keys, passwords, opened files and other sensitive data in the process – an aspect attackers are quick to exploit.  Here, stealthy malicious software based on isolated micro-controllers is implemented to conduct an attack analysis, the results of which provide the basis for developing a novel runtime detector. The detector reveals stealthy peripheral-based attacks on the host’s main memory by exploiting certain hardware properties, while a permanent and resource-efficient measurement strategy ensures that the detector is also capable of detecting transient attacks, which can otherwise succeed when the applied strategy only me...

  11. Planet Formation Imager (PFI) : science vision and key requirements

    NARCIS (Netherlands)

    Kraus, S.; Monnier, J.D.; Ireland, M.J.; Duchene, G.; Espaillat, C.; Honig, S.; Juhasz, A.; Mordasini, C.; Olofsson, J.; Paladini, C.; Stassun, K.; Turner, N.; Vasisht, G.; Harries, T.J.; Bate, M.R.; Gonzalez, J-F.; Matter, A.; Zhu, Z.; Panic, O.; Regaly, Z.; Morbidelli, A.; Meru, F.; Wolf, S.; Ilee, J.; Berger, J-P.; Zhao, M.; Kral, Q.; Morlok, A.; Bonsor, A.; Ciardi, D.; Kane, S.R.; Kratter, K.; Laughlin, G.; Pepper, J.; Raymond, S.; Labadie, L.; Nelson, R.P.; Weigelt, G.; Brummelaar, ten T.; Pierens, A.; Oudmaijer, R.; Kley, W.; Pope, B.; Jensen, E.L.N.; Bayo, A.; Smith, M.; Boyajian, T.; Quiroga-Nunez, L.H.; Millan-Gabet, R.; Chiavassa, A.; Gallenne, A.; Reynolds, M.; Wit, de W-J.; Wittkowski, M.; Millour, F.; Gandhi, P.; Ramos, A. C.; Alonso, H. A.; Packham, C.; Kishimoto, M.; Tristram, K.R.W.; Pott, J.-U.; Surdej, J.; Buscher, D.; Haniff, C.; Lacour, S.; Petrov, R.; Ridgway, S.; Tuthill, P.; Belle, van G.; Armitage, P.; Baruteau, C.; Benisty, M.; Bitsch, B.; Paardekooper, S-J.; Pinte, C.; Masset, F.; Rosotti, G.P.

    2016-01-01

    The Planet Formation Imager (PFI) project aims to provide a strong scientific vision for ground-based optical astronomy beyond the upcoming generation of Extremely Large Telescopes. We make the case that a breakthrough in angular resolution imaging capabilities is required in order to unravel the

  12. Case of Unilateral Peripheral Cone Dysfunction

    Directory of Open Access Journals (Sweden)

    Yujin Mochizuki

    2012-05-01

    Full Text Available Purpose: Peripheral cone dystrophy is a subgroup of cone dystrophy, and only 4 cases have been reported. We present a patient with unilateral peripheral cone dysfunction and report the functional changes determined by electrophysiological tests and ultrastructural changes determined by spectral domain optical coherence tomography (SD-OCT. Case: A 34-year-old woman complained of blurred vision in both eyes. Our examination showed that her visual acuity was 0.05 OD and 0.2 OS. A relative afferent pupillary defect was present in her right eye. The results of slit-lamp examination, ophthalmoscopy, and fluorescein angiography were normal except for pallor of the right optic disc. SD-OCT showed a diffuse thinning of the retina in the posterior pole of the right eye. A severe constriction of the visual fields was found in both eyes but more in the right eye. The photopic full-field electroretinograms (ERGs were reduced in the right eye but normal in the left eye. The multifocal ERGs were severely reduced throughout the visual field except in the central area of the right eye. The multifocal ERGs from the left eye were normal. The pattern visual evoked responses were within the normal range in both eyes. She had a 5-year history of sniffing paint thinner. Results: Although the visual dysfunction was initially suspected to be due to psychological problems from the results of subjective tests, objective tests indicated a peripheral cone dysfunction in the right eye. The pathophysiological mechanism and the relationship with thinner sniffing were not determined. Conclusions: Our findings indicate that peripheral cone dysfunction can occur unilaterally. Electrophysiology and SD-OCT are valuable tests to perform to determine the pathogenesis of unusual ocular findings objectively.

  13. Simple Radiowave-Based Method For Measuring Peripheral Blood Flow Project

    Science.gov (United States)

    Oliva-Buisson, Yvette J.

    2014-01-01

    Project objective is to design small radio frequency based flow probes for the measurement of blood flow velocity in peripheral arteries such as the femoral artery and middle cerebral artery. The result will be the technological capability to measure peripheral blood flow rates and flow changes during various environmental stressors such as microgravity without contact to the individual being monitored. This technology may also lead to an easier method of detecting venous gas emboli during extravehicular activities.

  14. HOLISTIC VISION: INTEGRATIVE APPROACH IN GUIDANCE AND COUNSELING SERVICES

    Directory of Open Access Journals (Sweden)

    Ade Hidayat

    2016-06-01

    Full Text Available Abstract: The philosophical issues in Guidance and Counseling especially in epistemological discourse have made paradigmatic friction that pointed by some issues from therapeutic-clinical to comprehensive way with preventive development prespective approach. It was also caused by the wider friction where quantum physic has remove classic Newtonian one, then the influence has generally removed another disciplines, where Guidance and Counseling in one of them. Through the comprehensive paradigm, Guidance dan Counseling need to take prepare the expert in order to capable to develop integrated and comprehensive thinking awareness. It means the Guidance and Counseling holistic vision is urged. Through the holistic vision, all of the competency of student is noticed integrally, such as intellectual, emotional, social, physical, artistic, creativity, ecological awareness, and spiritual competencies.Keywords: Ecoliteracy, Holictic Vision, Guidance and Counseling of Comprehensive.

  15. Multifragmentation in peripheral nucleus-nucleus collisions

    International Nuclear Information System (INIS)

    Trautmann, W.; Adloff, J.C.; Bouissou, P.; Hubele, J.; Imme, G.; Iori, I.; Kreutz, P.; Leray, S.; Lindenstruth, V.; Liu, Z.; Lynen, U.; Meijer, R.J.; Milkau, U.; Moroni, A.; Mueller, W.F.J.; Ngo, C.; Ogilvie, C.A.; Pochodzalla, J.; Raciti, G.; Rudolf, G.; Schuettauf, A.; Stuttge, L.

    1993-10-01

    The complete fragmentation of highly excited nuclear systems into fragments of intermediate mass is observed in heavy-ion reactions at relativistic bombarding energies in the range of several hundreds of MeV per nucleon. Similar features are found for peripheral collisions between heavy nuclei and for more central collisions between a heavy and a light nucleus. The partition space explored in multifragment decays is well described by the statistical multifragmentation models. The expansion before breakup is confirmed by the analysis of the measured fragment energies of ternary events in their own rest frame. Collective radial flow is confined to rather small values in these peripheral-type reactions. Many conceptually different models seem to be capable of reproducing the charge correlations measured for the multifragment decays. (orig.)

  16. Conceptual analysis of Physiology of vision in Ayurveda

    Directory of Open Access Journals (Sweden)

    Praveen Balakrishnan

    2014-01-01

    Full Text Available The process by which the world outside is seen is termed as visual process or physiology of vision. There are three phases in this visual process: phase of refraction of light, phase of conversion of light energy into electrical impulse and finally peripheral and central neurophysiology. With the advent of modern instruments step by step biochemical changes occurring at each level of the visual process has been deciphered. Many investigations have emerged to track these changes and helping to diagnose the exact nature of the disease. Ayurveda has described this physiology of vision based on the functions of vata and pitta. Philosophical textbook of ayurveda, Tarka Sangraha, gives certain basics facts of visual process. This article discusses the second and third phase of visual process. Step by step analysis of the visual process through the spectacles of ayurveda amalgamated with the basics of philosophy from Tarka Sangraha has been analyzed critically to generate a concrete idea regarding the physiology and hence thereby interpret the pathology on the grounds of ayurveda based on the investigative reports.

  17. 78 FR 20376 - Qualification of Drivers; Exemption Applications; Vision

    Science.gov (United States)

    2013-04-04

    ... professional opinion, I feel like this patient is visually able to drive a commercial motor vehicle.'' Mr... his visual function, I think he has sufficient vision to perform the tasks required to operate the... visually capable of performing driving tasks required to operate a commercial vehicle.'' Mr. Roy reported...

  18. Visual function and color vision in adults with Attention-Deficit/Hyperactivity Disorder.

    Science.gov (United States)

    Kim, Soyeon; Chen, Samantha; Tannock, Rosemary

    2014-01-01

    Color vision and self-reported visual function in everyday life in young adults with Attention-Deficit/Hyperactivity Disorder (ADHD) were investigated. Participants were 30 young adults with ADHD and 30 controls matched for age and gender. They were tested individually and completed the Visual Activities Questionnaire (VAQ), Farnsworth-Munsell 100 Hue Test (FMT) and A Quick Test of Cognitive Speed (AQT). The ADHD group reported significantly more problems in 4 of 8 areas on the VAQ: depth perception, peripheral vision, visual search and visual processing speed. Further analyses of VAQ items revealed that the ADHD group endorsed more visual problems associated with driving than controls. Color perception difficulties on the FMT were restricted to the blue spectrum in the ADHD group. FMT and AQT results revealed slower processing of visual stimuli in the ADHD group. A comprehensive investigation of mechanisms underlying visual function and color vision in adults with ADHD is warranted, along with the potential impact of these visual problems on driving performance. Copyright © 2013 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  19. Coherent laser vision system

    International Nuclear Information System (INIS)

    Sebastion, R.L.

    1995-01-01

    The Coherent Laser Vision System (CLVS) is being developed to provide precision real-time 3D world views to support site characterization and robotic operations and during facilities Decontamination and Decommissioning. Autonomous or semiautonomous robotic operations requires an accurate, up-to-date 3D world view. Existing technologies for real-time 3D imaging, such as AM laser radar, have limited accuracy at significant ranges and have variability in range estimates caused by lighting or surface shading. Recent advances in fiber optic component technology and digital processing components have enabled the development of a new 3D vision system based upon a fiber optic FMCW coherent laser radar. The approach includes a compact scanner with no-moving parts capable of randomly addressing all pixels. The system maintains the immunity to lighting and surface shading conditions which is characteristic to coherent laser radar. The random pixel addressability allows concentration of scanning and processing on the active areas of a scene, as is done by the human eye-brain system

  20. Coherent laser vision system

    Energy Technology Data Exchange (ETDEWEB)

    Sebastion, R.L. [Coleman Research Corp., Springfield, VA (United States)

    1995-10-01

    The Coherent Laser Vision System (CLVS) is being developed to provide precision real-time 3D world views to support site characterization and robotic operations and during facilities Decontamination and Decommissioning. Autonomous or semiautonomous robotic operations requires an accurate, up-to-date 3D world view. Existing technologies for real-time 3D imaging, such as AM laser radar, have limited accuracy at significant ranges and have variability in range estimates caused by lighting or surface shading. Recent advances in fiber optic component technology and digital processing components have enabled the development of a new 3D vision system based upon a fiber optic FMCW coherent laser radar. The approach includes a compact scanner with no-moving parts capable of randomly addressing all pixels. The system maintains the immunity to lighting and surface shading conditions which is characteristic to coherent laser radar. The random pixel addressability allows concentration of scanning and processing on the active areas of a scene, as is done by the human eye-brain system.

  1. Peripheral ulcerative keratitis associated with chronic malabsorption syndrome and miliary tuberculosis in a child

    Directory of Open Access Journals (Sweden)

    Tarun Arora

    2015-01-01

    Full Text Available A 16-year-old girl presented with pain, redness, watering, and blurring of vision in her right eye. Slit lamp examination revealed the presence of peripheral ulcerative keratitis (PUK and nodular scleritis. On clinical examination, the patient had stunted growth, low body mass index, and enlarged axillary nodes. Giardia cysts were present in the stool sample and histopathology of axillary lymph nodes showed caseating necrosis suggestive of tuberculosis (TB. A diagnosis of PUK with chronic malabsorption syndrome secondary to giardiasis and miliary TB was made. Oral metronidazole, anti-tubercular treatment, high protein diet and vitamin supplements were started. Topical steroids were started for peripheral ulcerative lesions following, which the PUK resolved.

  2. Behavioural evidence for colour vision in an elasmobranch.

    Science.gov (United States)

    Van-Eyk, Sarah M; Siebeck, Ulrike E; Champ, Connor M; Marshall, Justin; Hart, Nathan S

    2011-12-15

    Little is known about the sensory abilities of elasmobranchs (sharks, skates and rays) compared with other fishes. Despite their role as apex predators in most marine and some freshwater habitats, interspecific variations in visual function are especially poorly studied. Of particular interest is whether they possess colour vision and, if so, the role(s) that colour may play in elasmobranch visual ecology. The recent discovery of three spectrally distinct cone types in three different species of ray suggests that at least some elasmobranchs have the potential for functional trichromatic colour vision. However, in order to confirm that these species possess colour vision, behavioural experiments are required. Here, we present evidence for the presence of colour vision in the giant shovelnose ray (Glaucostegus typus) through the use of a series of behavioural experiments based on visual discrimination tasks. Our results show that these rays are capable of discriminating coloured reward stimuli from other coloured (unrewarded) distracter stimuli of variable brightness with a success rate significantly different from chance. This study represents the first behavioural evidence for colour vision in any elasmobranch, using a paradigm that incorporates extensive controls for relative stimulus brightness. The ability to discriminate colours may have a strong selective advantage for animals living in an aquatic ecosystem, such as rays, as a means of filtering out surface-wave-induced flicker.

  3. Binary pressure-sensitive paint measurements using miniaturised, colour, machine vision cameras

    Science.gov (United States)

    Quinn, Mark Kenneth

    2018-05-01

    Recent advances in machine vision technology and capability have led to machine vision cameras becoming applicable for scientific imaging. This study aims to demonstrate the applicability of machine vision colour cameras for the measurement of dual-component pressure-sensitive paint (PSP). The presence of a second luminophore component in the PSP mixture significantly reduces its inherent temperature sensitivity, increasing its applicability at low speeds. All of the devices tested are smaller than the cooled CCD cameras traditionally used and most are of significantly lower cost, thereby increasing the accessibility of such technology and techniques. Comparisons between three machine vision cameras, a three CCD camera, and a commercially available specialist PSP camera are made on a range of parameters, and a detailed PSP calibration is conducted in a static calibration chamber. The findings demonstrate that colour machine vision cameras can be used for quantitative, dual-component, pressure measurements. These results give rise to the possibility of performing on-board dual-component PSP measurements in wind tunnels or on real flight/road vehicles.

  4. Vision-based path following using the 1D trifocal tensor

    CSIR Research Space (South Africa)

    Sabatta, D

    2013-05-01

    Full Text Available In this paper we present a vision-based path following algorithm for a non-holonomic wheeled platform capable of keeping the vehicle on a desired path using only a single camera. The algorithm is suitable for teach and replay or leader...

  5. Development of Non-contact Respiratory Monitoring System for Newborn Using a FG Vision Sensor

    Science.gov (United States)

    Kurami, Yoshiyuki; Itoh, Yushi; Natori, Michiya; Ohzeki, Kazuo; Aoki, Yoshimitsu

    In recent years, development of neonatal care is strongly hoped, with increase of the low-birth-weight baby birth rate. Especially respiration of low-birth-weight baby is incertitude because central nerve and respiratory function is immature. Therefore, a low-birth-weight baby often causes a disease of respiration. In a NICU (Neonatal Intensive Care Unit), neonatal respiration is monitored using cardio-respiratory monitor and pulse oximeter at all times. These contact-type sensors can measure respiratory rate and SpO2 (Saturation of Peripheral Oxygen). However, because a contact-type sensor might damage the newborn's skin, it is a real burden to monitor neonatal respiration. Therefore, we developed the respiratory monitoring system for newborn using a FG (Fiber Grating) vision sensor. FG vision sensor is an active stereo vision sensor, it is possible for non-contact 3D measurement. A respiratory waveform is calculated by detecting the vertical motion of the thoracic and abdominal region with respiration. We attempted clinical experiment in the NICU, and confirmed the accuracy of the obtained respiratory waveform was high. Non-contact respiratory monitoring of newborn using a FG vision sensor enabled the minimally invasive procedure.

  6. Using Weightless Neural Networks for Vergence Control in an Artificial Vision System

    Directory of Open Access Journals (Sweden)

    Karin S. Komati

    2003-01-01

    Full Text Available This paper presents a methodology we have developed and used to implement an artificial binocular vision system capable of emulating the vergence of eye movements. This methodology involves using weightless neural networks (WNNs as building blocks of artificial vision systems. Using the proposed methodology, we have designed several architectures of WNN-based artificial vision systems, in which images captured by virtual cameras are used for controlling the position of the ‘foveae’ of these cameras (high-resolution region of the images captured. Our best architecture is able to control the foveae vergence movements with average error of only 3.58 image pixels, which is equivalent to an angular error of approximately 0.629°.

  7. Computer vision camera with embedded FPGA processing

    Science.gov (United States)

    Lecerf, Antoine; Ouellet, Denis; Arias-Estrada, Miguel

    2000-03-01

    Traditional computer vision is based on a camera-computer system in which the image understanding algorithms are embedded in the computer. To circumvent the computational load of vision algorithms, low-level processing and imaging hardware can be integrated in a single compact module where a dedicated architecture is implemented. This paper presents a Computer Vision Camera based on an open architecture implemented in an FPGA. The system is targeted to real-time computer vision tasks where low level processing and feature extraction tasks can be implemented in the FPGA device. The camera integrates a CMOS image sensor, an FPGA device, two memory banks, and an embedded PC for communication and control tasks. The FPGA device is a medium size one equivalent to 25,000 logic gates. The device is connected to two high speed memory banks, an IS interface, and an imager interface. The camera can be accessed for architecture programming, data transfer, and control through an Ethernet link from a remote computer. A hardware architecture can be defined in a Hardware Description Language (like VHDL), simulated and synthesized into digital structures that can be programmed into the FPGA and tested on the camera. The architecture of a classical multi-scale edge detection algorithm based on a Laplacian of Gaussian convolution has been developed to show the capabilities of the system.

  8. Pediatric Low Vision

    Science.gov (United States)

    ... Asked Questions Español Condiciones Chinese Conditions Pediatric Low Vision What is Low Vision? Partial vision loss that cannot be corrected causes ... and play. What are the signs of Low Vision? Some signs of low vision include difficulty recognizing ...

  9. Low Vision FAQs

    Science.gov (United States)

    ... de los Ojos Cómo hablarle a su oculista Low Vision FAQs What is low vision? Low vision is a visual impairment, not correctable ... person’s ability to perform everyday activities. What causes low vision? Low vision can result from a variety of ...

  10. 75 FR 30383 - NOAA's Arctic Vision and Strategy; Comment Period Extension

    Science.gov (United States)

    2010-06-01

    ... DEPARTMENT OF COMMERCE National Oceanic and Atmospheric Administration RIN 0648-XT64 NOAA's Arctic.... ACTION: Request for comments. SUMMARY: NOAA wishes to ensure its Arctic Vision and Strategy document..., and coastal communities. Though NOAA has numerous and diverse capabilities that support these emerging...

  11. The risk of pedestrian collisions with peripheral visual field loss.

    Science.gov (United States)

    Peli, Eli; Apfelbaum, Henry; Berson, Eliot L; Goldstein, Robert B

    2016-12-01

    Patients with peripheral field loss complain of colliding with other pedestrians in open-space environments such as shopping malls. Field expansion devices (e.g., prisms) can create artificial peripheral islands of vision. We investigated the visual angle at which these islands can be most effective for avoiding pedestrian collisions, by modeling the collision risk density as a function of bearing angle of pedestrians relative to the patient. Pedestrians at all possible locations were assumed to be moving in all directions with equal probability within a reasonable range of walking speeds. The risk density was found to be highly anisotropic. It peaked at ≈45° eccentricity. Increasing pedestrian speed range shifted the risk to higher eccentricities. The risk density is independent of time to collision. The model results were compared to the binocular residual peripheral island locations of 42 patients with forms of retinitis pigmentosa. The natural residual island prevalence also peaked nasally at about 45° but temporally at about 75°. This asymmetry resulted in a complementary coverage of the binocular field of view. Natural residual binocular island eccentricities seem well matched to the collision-risk density function, optimizing detection of other walking pedestrians (nasally) and of faster hazards (temporally). Field expansion prism devices will be most effective if they can create artificial peripheral islands at about 45° eccentricities. The collision risk and residual island findings raise interesting questions about normal visual development.

  12. Peripheral neuropathy

    Science.gov (United States)

    ... peripheral; Neuritis - peripheral; Nerve disease; Polyneuropathy; Chronic pain - peripheral neuropathy ... Philadelphia, PA: Elsevier; 2016:chap 107. Shy ME. Peripheral neuropathies. In: Goldman L, Schafer AI, eds. Goldman's Cecil ...

  13. Vision in high-level football officials.

    Directory of Open Access Journals (Sweden)

    António Manuel Gonçalves Baptista

    23.9% wear contact lenses when officiating. Clinical vision measures in the football officials were similar to published normative values for young, adult populations and similar between R and AR. Clinically-measured vision did not differ according to officiating level. Visual acuity measured with and without a pinhole disc indicated that around one quarter of participants may be capable of better vision when officiating, as evidenced by better acuity (≥1 line of letters using the pinhole. Amongst the clinical visual tests we used, we did not find evidence for above-average performance in elite-level football officials. Although the impact of uncorrected mild to moderate refractive error upon officiating performance is unknown, with a greater uptake of eye examinations, visual acuity may be improved in around a quarter of officials.

  14. Environmental and Personal Safety: No Vision Required. Practice Report

    Science.gov (United States)

    Bozeman, Laura A.

    2004-01-01

    Personal safety is an important issue for all people, regardless of their physical capabilities. For people with visual impairments (that is, those who are blind or have low vision), real concerns exist regarding their vulnerability to crime and their greater risk of attack. With a nationwide increase in crime in the United States, "Three out of…

  15. Restoration of vision after transplantation of photoreceptors.

    Science.gov (United States)

    Pearson, R A; Barber, A C; Rizzi, M; Hippert, C; Xue, T; West, E L; Duran, Y; Smith, A J; Chuang, J Z; Azam, S A; Luhmann, U F O; Benucci, A; Sung, C H; Bainbridge, J W; Carandini, M; Yau, K-W; Sowden, J C; Ali, R R

    2012-05-03

    Cell transplantation is a potential strategy for treating blindness caused by the loss of photoreceptors. Although transplanted rod-precursor cells are able to migrate into the adult retina and differentiate to acquire the specialized morphological features of mature photoreceptor cells, the fundamental question remains whether transplantation of photoreceptor cells can actually improve vision. Here we provide evidence of functional rod-mediated vision after photoreceptor transplantation in adult Gnat1−/− mice, which lack rod function and are a model of congenital stationary night blindness. We show that transplanted rod precursors form classic triad synaptic connections with second-order bipolar and horizontal cells in the recipient retina. The newly integrated photoreceptor cells are light-responsive with dim-flash kinetics similar to adult wild-type photoreceptors. By using intrinsic imaging under scotopic conditions we demonstrate that visual signals generated by transplanted rods are projected to higher visual areas, including V1. Moreover, these cells are capable of driving optokinetic head tracking and visually guided behaviour in the Gnat1−/− mouse under scotopic conditions. Together, these results demonstrate the feasibility of photoreceptor transplantation as a therapeutic strategy for restoring vision after retinal degeneration.

  16. Patient-reported vision-related quality of life differences between superior and inferior hemifield visual field defects in primary open-angle glaucoma.

    Science.gov (United States)

    Cheng, Hui-Chen; Guo, Chao-Yu; Chen, Mei-Ju; Ko, Yu-Chieh; Huang, Nicole; Liu, Catherine Jui-ling

    2015-03-01

    Previous studies have found that glaucoma is associated with impaired patient-reported vision-related quality of life (pVRQOL) but few, to our knowledge, have assessed how the visual field (VF) defect location impacts the pVRQOL. To investigate the associations of VF defects in the superior vs inferior hemifields with pVRQOL outcomes in patients with primary open-angle glaucoma. Prospective cross-sectional study at a tertiary referral center from March 1, 2012, to January 1, 2013, including patients with primary open-angle glaucoma who had a best-corrected visual acuity in the better eye equal to or better than 20/60 and reliable VF tests. The pVRQOL was assessed by a validated Taiwanese version of the 25-item National Eye Institute Visual Function Questionnaire. Reliable VF tests obtained within 3 months of enrollment were transformed to binocular integrated VF (IVF). The IVF was further stratified by VF location (superior vs inferior hemifield). The association between each domain of the 25-item National Eye Institute Visual Function Questionnaire and superior or inferior hemifield IVF was determined using multivariable linear regression analysis. The analysis included 186 patients with primary open-angle glaucoma with a mean age of 59.1 years (range, 19-86 years) and IVF mean deviation (MD) of -4.84 dB (range, -27.56 to 2.17 dB). In the multivariable linear regression analysis, the MD of the full-field IVF showed positive associations with near activities (β = 0.05; R2 = 0.20; P < .001), vision-specific role difficulties (β = 0.04; R2 = 0.19; P = .01), vision-specific dependency (β = 0.04; R2 = 0.20; P < .001), driving (β = 0.05; R2 = 0.24; P < .001), peripheral vision (β = 0.03; R2 = 0.18; P = .02), and composite scores (β = 0.04; R2 = 0.27; P = .005). Subsequent analysis showed that the MD of the superior hemifield IVF was associated only with near activities (β = 0.04; R2

  17. Peripheral refraction in normal infant rhesus monkeys

    Science.gov (United States)

    Hung, Li-Fang; Ramamirtham, Ramkumar; Huang, Juan; Qiao-Grider, Ying; Smith, Earl L.

    2008-01-01

    Purpose To characterize peripheral refractions in infant monkeys. Methods Cross-sectional data for horizontal refractions were obtained from 58 normal rhesus monkeys at 3 weeks of age. Longitudinal data were obtained for both the vertical and horizontal meridians from 17 monkeys. Refractive errors were measured by retinoscopy along the pupillary axis and at eccentricities of 15, 30, and 45 degrees. Axial dimensions and corneal power were measured by ultrasonography and keratometry, respectively. Results In infant monkeys, the degree of radial astigmatism increased symmetrically with eccentricity in all meridians. There were, however, initial nasal-temporal and superior-inferior asymmetries in the spherical-equivalent refractive errors. Specifically, the refractions in the temporal and superior fields were similar to the central ametropia, but the refractions in the nasal and inferior fields were more myopic than the central ametropia and the relative nasal field myopia increased with the degree of central hyperopia. With age, the degree of radial astigmatism decreased in all meridians and the refractions became more symmetrical along both the horizontal and vertical meridians; small degrees of relative myopia were evident in all fields. Conclusions As in adult humans, refractive error varied as a function of eccentricity in infant monkeys and the pattern of peripheral refraction varied with the central refractive error. With age, emmetropization occurred for both central and peripheral refractive errors resulting in similar refractions across the central 45 degrees of the visual field, which may reflect the actions of vision-dependent, growth-control mechanisms operating over a wide area of the posterior globe. PMID:18487366

  18. 3D printing strategies for peripheral nerve regeneration.

    Science.gov (United States)

    Petcu, Eugen B; Midha, Rajiv; McColl, Erin; Popa-Wagner, Aurel; Chirila, Traian V; Dalton, Paul D

    2018-03-23

    After many decades of biomaterials research for peripheral nerve regeneration, a clinical product (the nerve guide), is emerging as a proven alternative for relatively short injury gaps. This review identifies aspects where 3D printing can assist in improving long-distance nerve guide regeneration strategies. These include (1) 3D printing of the customizable nerve guides, (2) fabrication of scaffolds that fill nerve guides, (3) 3D bioprinting of cells within a matrix/bioink into the nerve guide lumen and the (4) establishment of growth factor gradients along the length a nerve guide. The improving resolution of 3D printing technologies will be an important factor for peripheral nerve regeneration, as fascicular-like guiding structures provide one path to improved nerve guidance. The capability of 3D printing to manufacture complex structures from patient data based on existing medical imaging technologies is an exciting aspect that could eventually be applied to treating peripheral nerve injury. Ultimately, the goal of 3D printing in peripheral nerve regeneration is the automated fabrication, potentially customized for the patient, of structures within the nerve guide that significantly outperform the nerve autograft over large gap injuries.

  19. Zilog UPC, a higher performance slave peripheral controller

    Energy Technology Data Exchange (ETDEWEB)

    Walters, S.M.

    1982-01-01

    The universal peripheral controllers Z8090 and Z8590 (UPC) is an intelligent peripheral controller. It may be mask-programmed to execute dedicated I/O tasks that would otherwise need to be done by the host microprocessor. The UPC is actually a single-chip microcomputer with a complete host bus interface on-chip. It offers the hardware features of a programmable parallel I/O port, a programmable counter/timer, an I/O buffer RAM, and an intelligent interrupt controller. In addition, it provides a stored program processing element that is capable of pre-processing information before it is transferred to the host. Perhaps as important as its features is the fact that when used in volume, the UPC will be comparable in cost to non-programmable LSI parallel I/O and counter/timer functions. The UPC, simply stated, offers a cost effective multi-processor approach for offloading the host microprocessor of routine peripheral control tasks in high volume applications.

  20. Machine vision applications for physical security, quality assurance and personnel dosimetry

    International Nuclear Information System (INIS)

    Kar, S.; Shrikhande, S.V.; Suresh Babu, R.M.

    2016-01-01

    Machine vision is the technology used to provide imaging-based solutions to variety of applications, relevant to nuclear facilities and other industries. It uses computerized image analysis for automatic inspection, process control, object sorting, parts assembly, human identity authentication, and so on. In this article we discuss the in-house developed machine vision systems at EISD, BARC for three specific areas: Biometric recognition for physical security, visual inspection for QA of fuel pellets, and fast neutron personnel dosimetry. The advantages in using these systems include objective decision making, reduced man-rem, operational consistency, and capability of statistical quantitative analysis. (author)

  1. Grounding Our Vision: Brain Research and Strategic Vision

    Science.gov (United States)

    Walker, Mike

    2011-01-01

    While recognizing the value of "vision," it could be argued that vision alone--at least in schools--is not enough to rally the financial and emotional support required to translate an idea into reality. A compelling vision needs to reflect substantive, research-based knowledge if it is to spark the kind of strategic thinking and insight…

  2. Investigation into the use of smartphone as a machine vision device for engineering metrology and flaw detection, with focus on drilling

    Science.gov (United States)

    Razdan, Vikram; Bateman, Richard

    2015-05-01

    This study investigates the use of a Smartphone and its camera vision capabilities in Engineering metrology and flaw detection, with a view to develop a low cost alternative to Machine vision systems which are out of range for small scale manufacturers. A Smartphone has to provide a similar level of accuracy as Machine Vision devices like Smart cameras. The objective set out was to develop an App on an Android Smartphone, incorporating advanced Computer vision algorithms written in java code. The App could then be used for recording measurements of Twist Drill bits and hole geometry, and analysing the results for accuracy. A detailed literature review was carried out for in-depth study of Machine vision systems and their capabilities, including a comparison between the HTC One X Android Smartphone and the Teledyne Dalsa BOA Smart camera. A review of the existing metrology Apps in the market was also undertaken. In addition, the drilling operation was evaluated to establish key measurement parameters of a twist Drill bit, especially flank wear and diameter. The methodology covers software development of the Android App, including the use of image processing algorithms like Gaussian Blur, Sobel and Canny available from OpenCV software library, as well as designing and developing the experimental set-up for carrying out the measurements. The results obtained from the experimental set-up were analysed for geometry of Twist Drill bits and holes, including diametrical measurements and flaw detection. The results show that Smartphones like the HTC One X have the processing power and the camera capability to carry out metrological tasks, although dimensional accuracy achievable from the Smartphone App is below the level provided by Machine vision devices like Smart cameras. A Smartphone with mechanical attachments, capable of image processing and having a reasonable level of accuracy in dimensional measurement, has the potential to become a handy low-cost Machine vision

  3. Intelligent vision in the nuclear industry

    International Nuclear Information System (INIS)

    Luna, F.

    1983-01-01

    General Electric has developed an intelligent microprocessor-based machine vision system that is character font independent and is capable of reading characters that may be variably defined as a result of dirt, misalignment, or scratches incurred during processing. This system, the Alphavision System, was developed at the GE fuel fabrication facility in Wilmington, North Carolina, and has been used to read serial numbers on fuel rods. This paper describes the system and considerations for its use and suggests some potential applications in nuclear materials item accountability

  4. Experiences of vision impairment in Papua New Guinea: implications for blindness prevention programs.

    Science.gov (United States)

    Burnett, Anthea; Yashadhana, Aryati; Cabrera Aguas, Maria; Hanni, Yvonne; Yu, Mitasha

    2016-01-01

    A person's capability to access services and achieve good eye health is influenced by their behaviours, perceptions, beliefs and experiences. As evidence from Papua New Guinea (PNG) about people's lived experience with vision impairment is limited, the purpose of the present study was to better understand the beliefs, perceptions and emotional responses to vision impairment in PNG. A qualitative study, using both purposive and convenience sampling, was undertaken to explore common beliefs and perceptions about vision impairment, as well as the emotional responses to vision impairment. In-depth interviews were undertaken with 51 adults from five provinces representing culturally and geographically diverse regions of PNG. Grounded theory was used to elicit key themes from interview data. Participants described activities of everyday life impacted by vision impairment and the related worry, sadness and social exclusion. Common beliefs about the causes of vision impairment were environmental stressors (sun, dust, dirt and smoke), ageing and sorcery. Findings provide insight into the unique social context in PNG and identify a number of programmatic and policy implications, such as the need for preventative eye health information and services, addressing persisting beliefs in sorcery when developing health information packages, and the importance of coordinating with counselling and well-being services for people experiencing vision impairment.

  5. The Distinct Role of the Amygdala, Superior Colliculus and Pulvinar in Processing of Central and Peripheral Snakes.

    Directory of Open Access Journals (Sweden)

    Inês Almeida

    Full Text Available Visual processing of ecologically relevant stimuli involves a central bias for stimuli demanding detailed processing (e.g., faces, whereas peripheral object processing is based on coarse identification. Fast detection of animal shapes holding a significant phylogenetic value, such as snakes, may benefit from peripheral vision. The amygdala together with the pulvinar and the superior colliculus are implicated in an ongoing debate regarding their role in automatic and deliberate spatial processing of threat signals.Here we tested twenty healthy participants in an fMRI task, and investigated the role of spatial demands (the main effect of central vs. peripheral vision in the processing of fear-relevant ecological features. We controlled for stimulus dependence using true or false snakes; snake shapes or snake faces and for task constraints (implicit or explicit. The main idea justifying this double task is that amygdala and superior colliculus are involved in both automatic and controlled processes. Moreover the explicit/implicit instruction in the task with respect to emotion is not necessarily equivalent to explicit vs. implicit in the sense of endogenous vs. exogenous attention, or controlled vs. automatic processes.We found that stimulus-driven processing led to increased amygdala responses specifically to true snake shapes presented in the centre or in the peripheral left hemifield (right hemisphere. Importantly, the superior colliculus showed significantly biased and explicit central responses to snake-related stimuli. Moreover, the pulvinar, which also contains foveal representations, also showed strong central responses, extending the results of a recent single cell pulvinar study in monkeys. Similar hemispheric specialization was found across structures: increased amygdala responses occurred to true snake shapes presented to the right hemisphere, with this pattern being closely followed by the superior colliculus and the pulvinar

  6. A Layered Active Memory Architecture for Cognitive Vision Systems

    OpenAIRE

    Kolonias, Ilias; Christmas, William; Kittler, Josef

    2007-01-01

    Recognising actions and objects from video material has attracted growing research attention and given rise to important applications. However, injecting cognitive capabilities into computer vision systems requires an architecture more elaborate than the traditional signal processing paradigm for information processing. Inspired by biological cognitive systems, we present a memory architecture enabling cognitive processes (such as selecting the processes required for scene understanding, laye...

  7. A vision-based driver nighttime assistance and surveillance system based on intelligent image sensing techniques and a heterogamous dual-core embedded system architecture.

    Science.gov (United States)

    Chen, Yen-Lin; Chiang, Hsin-Han; Chiang, Chuan-Yen; Liu, Chuan-Ming; Yuan, Shyan-Ming; Wang, Jenq-Haur

    2012-01-01

    This study proposes a vision-based intelligent nighttime driver assistance and surveillance system (VIDASS system) implemented by a set of embedded software components and modules, and integrates these modules to accomplish a component-based system framework on an embedded heterogamous dual-core platform. Therefore, this study develops and implements computer vision and sensing techniques of nighttime vehicle detection, collision warning determination, and traffic event recording. The proposed system processes the road-scene frames in front of the host car captured from CCD sensors mounted on the host vehicle. These vision-based sensing and processing technologies are integrated and implemented on an ARM-DSP heterogamous dual-core embedded platform. Peripheral devices, including image grabbing devices, communication modules, and other in-vehicle control devices, are also integrated to form an in-vehicle-embedded vision-based nighttime driver assistance and surveillance system.

  8. [Surgical treatment of advanced retinopathy of prematurity--last chance for vision. Report 2. Analysis of functional results].

    Science.gov (United States)

    Baranov, A V; Troianovskiĭ, R L

    2012-01-01

    Functional results of staged surgical treatment of advanced retinopathy of prematurity (ROP) are analyzed between 2005 and 2010 in ophthalmologic department of city children's hospital ( St. Petersburg). A total of 154 children (303 eyes) were operated. The assessment of visual functions was performed using proposed original method. Subject vision was achieved in 65% of 20 eyes (6,6%) with 4B stage ROP. Fair anatomic results were achieved in 131 eyes of children with 5 stage ROP (283 eyes), light perception was preserved in 52 eyes (39,7%), capability to distinguish large objects appeared in 40 eyes (30,5%) and subject vision developed in 39 eyes (29,8%). Correlation between visual functions and environmental conditions was found, in particular presence or absence of long-term period of training in color and individual objects distinguishing. In a group of children training resulted in achievement of fair functions (subject vision, capability to distinguish large objects) in 81,2% of patients, where as in a group without training the same capabilities developed in 31,8% of cases only. Functional outcomes were also found to depend on CNS condition and time of surgery.

  9. Computational vision

    CERN Document Server

    Wechsler, Harry

    1990-01-01

    The book is suitable for advanced courses in computer vision and image processing. In addition to providing an overall view of computational vision, it contains extensive material on topics that are not usually covered in computer vision texts (including parallel distributed processing and neural networks) and considers many real applications.

  10. Making a vision document tangible using "vision-tactics-metrics" tables.

    Science.gov (United States)

    Drury, Ivo; Slomski, Carol

    2006-01-01

    We describe a method of making a vision document tangible by attaching specific tactics and metrics to the key elements of the vision. We report on the development and early use of a "vision-tactics-metrics" table in a department of surgery. Use of the table centered the vision in the daily life of the department and its faculty, and facilitated cultural change.

  11. Perception of linear horizontal self-motion induced by peripheral vision /linearvection/ - Basic characteristics and visual-vestibular interactions

    Science.gov (United States)

    Berthoz, A.; Pavard, B.; Young, L. R.

    1975-01-01

    The basic characteristics of the sensation of linear horizontal motion have been studied. Objective linear motion was induced by means of a moving cart. Visually induced linear motion perception (linearvection) was obtained by projection of moving images at the periphery of the visual field. Image velocity and luminance thresholds for the appearance of linearvection have been measured and are in the range of those for image motion detection (without sensation of self motion) by the visual system. Latencies of onset are around 1 sec and short term adaptation has been shown. The dynamic range of the visual analyzer as judged by frequency analysis is lower than the vestibular analyzer. Conflicting situations in which visual cues contradict vestibular and other proprioceptive cues show, in the case of linearvection a dominance of vision which supports the idea of an essential although not independent role of vision in self motion perception.

  12. Reading performance with low-vision aids and vision-related quality of life after macular translocation surgery in patients with age-related macular degeneration.

    Science.gov (United States)

    Nguyen, Nhung X; Besch, Dorothea; Bartz-Schmidt, Karl; Gelisken, Faik; Trauzettel-Klosinski, Susanne

    2007-12-01

    The aim of the present study was to evaluate the power of magnification required, reading performance with low-vision aids and vision-related quality of life with reference to reading ability and ability to carry out day-to-day activities in patients after macular translocation. This study included 15 patients who had undergone macular translocation with 360-degree peripheral retinectomy. The mean length of follow-up was 19.2 +/- 10.8 months (median 11 months). At the final examination, the impact of visual impairment on reading ability and quality of life was assessed according to a modified 9-item questionnaire in conjunction with a comprehensive clinical examination, which included assessment of best corrected visual acuity (BCVA), the magnification power required for reading, use of low-vision aids and reading speed. Patients rated the extent to which low vision restricted their ability to read and participate in other activities that affect quality of life. Responses were scored on a scale of 1.0 (optimum self-evaluation) to 5.0 (very poor). In the operated eye, overall mean postoperative BCVA (distance) was not significantly better than mean preoperative BCVA (0.11 +/- 0.06 and 0.15 +/- 0.08, respectively; p = 0.53). However, 53% of patients reported a subjective increase in visual function after treatment. At the final visit, the mean magnification required was x 7.7 +/- 6.7. A total of 60% of patients needed optical magnifiers for reading and in 40% of patients closed-circuit TV systems were necessary. All patients were able to read newspaper print using adapted low-vision aids at a mean reading speed of 71 +/- 40 words per minute. Mean self-reported scores were 3.2 +/- 1.1 for reading, 2.5 +/- 0.7 for day-to-day activities and 2.7 +/- 3.0 for outdoor walking and using steps or stairs. Patients' levels of dependency were significantly correlated with scores for reading (p = 0.01), day-to-day activities (p vision-related quality of life in patients after

  13. Machine vision-based high-resolution weed mapping and patch-sprayer performance simulation

    NARCIS (Netherlands)

    Tang, L.; Tian, L.F.; Steward, B.L.

    1999-01-01

    An experimental machine vision-based patch-sprayer was developed. This sprayer was primarily designed to do real-time weed density estimation and variable herbicide application rate control. However, the sprayer also had the capability to do high-resolution weed mapping if proper mapping techniques

  14. Machine learning, computer vision, and probabilistic models in jet physics

    CERN Multimedia

    CERN. Geneva; NACHMAN, Ben

    2015-01-01

    In this talk we present recent developments in the application of machine learning, computer vision, and probabilistic models to the analysis and interpretation of LHC events. First, we will introduce the concept of jet-images and computer vision techniques for jet tagging. Jet images enabled the connection between jet substructure and tagging with the fields of computer vision and image processing for the first time, improving the performance to identify highly boosted W bosons with respect to state-of-the-art methods, and providing a new way to visualize the discriminant features of different classes of jets, adding a new capability to understand the physics within jets and to design more powerful jet tagging methods. Second, we will present Fuzzy jets: a new paradigm for jet clustering using machine learning methods. Fuzzy jets view jet clustering as an unsupervised learning task and incorporate a probabilistic assignment of particles to jets to learn new features of the jet structure. In particular, we wi...

  15. Virtual environment assessment for laser-based vision surface profiling

    Science.gov (United States)

    ElSoussi, Adnane; Al Alami, Abed ElRahman; Abu-Nabah, Bassam A.

    2015-03-01

    Oil and gas businesses have been raising the demand from original equipment manufacturers (OEMs) to implement a reliable metrology method in assessing surface profiles of welds before and after grinding. This certainly mandates the deviation from the commonly used surface measurement gauges, which are not only operator dependent, but also limited to discrete measurements along the weld. Due to its potential accuracy and speed, the use of laser-based vision surface profiling systems have been progressively rising as part of manufacturing quality control. This effort presents a virtual environment that lends itself for developing and evaluating existing laser vision sensor (LVS) calibration and measurement techniques. A combination of two known calibration techniques is implemented to deliver a calibrated LVS system. System calibration is implemented virtually and experimentally to scan simulated and 3D printed features of known profiles, respectively. Scanned data is inverted and compared with the input profiles to validate the virtual environment capability for LVS surface profiling and preliminary assess the measurement technique for weld profiling applications. Moreover, this effort brings 3D scanning capability a step closer towards robust quality control applications in a manufacturing environment.

  16. Journey to a shared vision for nursing in a university hospital

    Directory of Open Access Journals (Sweden)

    Jacqueline S. Martin

    2016-11-01

    Full Text Available Background: Demographic and epidemiological shifts, as well as increasing quality control and greater emphasis on cost effectiveness are the challenges for today’s healthcare organisations. Against this background, institutions are undertaking reforming processes in order to adapt to this complex and unstable market. These transformations require innovative practice and highly effective leadership – leaders who are capable of conveying the need for change and creating a vision for the future. Despite its growing importance, the development process of such a vision is barely addressed in the literature. Aim: The aim of this article is to describe the process of a university hospital towards developing a shared vision for nursing practice. Methods: By means of the four phases of the evidence-based appreciative inquiry process (Discovery – Dream – Design – Destiny, a shared vision was developed. The main methods used were individual interviews, focus group interviews and SWOT analyses. The different datasets produced were synthesised and abstracted to form a vision and corresponding strategic objectives. Conclusions: Although the developmental process was rather time consuming and complex, it provided a systematic approach to change and enabled the leaders involved to commit to the strategic orientation. Implications for practice: A vision provides direction and meaning for leaders and their teams in complex transformation processes within healthcare organisations The approach of appreciative inquiry is well suited to facilitate the creative and innovative process of developing a vision Before initiating the process of developing a vision, it is important to consider the time factor and to plan accordingly so that the necessary creative thinking and reflection can take place

  17. Near vision spectacle coverage and barriers to near vision ...

    African Journals Online (AJOL)

    easily help to address this visual disability.7 An average cost of near vision spectacle in Ghana is approximately. $ 5.8 Near-vision spectacle could be dispensed as single vision, bifocal or progressive eye glasses to meet near vi- sion needs.2. Recent evidence suggests that the ageing population in. Ghana is increasing ...

  18. A real time tracking vision system and its application to robotics

    International Nuclear Information System (INIS)

    Inoue, Hirochika

    1994-01-01

    Among various sensing channels the vision is most important for making robot intelligent. If provided with a high speed visual tracking capability, the robot-environment interaction becomes dynamic instead of static, and thus the potential repertoire of robot behavior becomes very rich. For this purpose we developed a real-time tracking vision system. The fundamental operation on which our system based is the calculation of correlation between local images. Use of special chip for correlation and the multi-processor configuration enable the robot to track more than hundreds cues in full video rate. In addition to the fundamental visual performance, applications for robot behavior control are also introduced. (author)

  19. AN INVESTIGATION OF VISION PROBLEMS AND THE VISION CARE SYSTEM IN RURAL CHINA.

    Science.gov (United States)

    Bai, Yunli; Yi, Hongmei; Zhang, Linxiu; Shi, Yaojiang; Ma, Xiaochen; Congdon, Nathan; Zhou, Zhongqiang; Boswell, Matthew; Rozelle, Scott

    2014-11-01

    This paper examines the prevalence of vision problems and the accessibility to and quality of vision care in rural China. We obtained data from 4 sources: 1) the National Rural Vision Care Survey; 2) the Private Optometrists Survey; 3) the County Hospital Eye Care Survey; and 4) the Rural School Vision Care Survey. The data from each of the surveys were collected by the authors during 2012. Thirty-three percent of the rural population surveyed self-reported vision problems. Twenty-two percent of subjects surveyed had ever had a vision exam. Among those who self-reported having vision problems, 34% did not wear eyeglasses. Fifty-four percent of those with vision problems who had eyeglasses did not have a vision exam prior to receiving glasses. However, having a vision exam did not always guarantee access to quality vision care. Four channels of vision care service were assessed. The school vision examination program did not increase the usage rate of eyeglasses. Each county-hospital was staffed with three eye-doctors having one year of education beyond high school, serving more than 400,000 residents. Private optometrists often had low levels of education and professional certification. In conclusion, our findings shows that the vision care system in rural China is inadequate and ineffective in meeting the needs of the rural population sampled.

  20. Space-time relationship in continuously moving table method for large FOV peripheral contrast-enhanced magnetic resonance angiography

    International Nuclear Information System (INIS)

    Sabati, M; Lauzon, M L; Frayne, R

    2003-01-01

    Data acquisition using a continuously moving table approach is a method capable of generating large field-of-view (FOV) 3D MR angiograms. However, in order to obtain venous contamination-free contrast-enhanced (CE) MR angiograms in the lower limbs, one of the major challenges is to acquire all necessary k-space data during the restricted arterial phase of the contrast agent. Preliminary investigation on the space-time relationship of continuously acquired peripheral angiography is performed in this work. Deterministic and stochastic undersampled hybrid-space (x, k y , k z ) acquisitions are simulated for large FOV peripheral runoff studies. Initial results show the possibility of acquiring isotropic large FOV images of the entire peripheral vascular system. An optimal trade-off between the spatial and temporal sampling properties was found that produced a high-spatial resolution peripheral CE-MR angiogram. The deterministic sampling pattern was capable of reconstructing the global structure of the peripheral arterial tree and showed slightly better global quantitative results than stochastic patterns. Optimal stochastic sampling patterns, on the other hand, enhanced small vessels and had more favourable local quantitative results. These simulations demonstrate the complex spatial-temporal relationship when sampling large FOV peripheral runoff studies. They also suggest that more investigation is required to maximize image quality as a function of hybrid-space coverage, acquisition repetition time and sampling pattern parameters

  1. Optical coherent tomography in diagnoses of peripheral retinal degenarations

    Directory of Open Access Journals (Sweden)

    O. G. Pozdeyeva

    2013-01-01

    Full Text Available Purpose: Studying the capabilities of optical coherence tomography (RTVue-100, OPTOVUE, USA in evaluation of peripheral retinal degenerations, vitreoretinal adhesions, adjacent vitreous body as well as measurement of morphometric data.Methods: The study included 189 patients (239 eyes with peripheral retinal degeneration. 77 men and 112 women aged 18 to 84 underwent an ophthalmologic examination since November 2012 until October 2013. The peripheral retina was visualized with the help of optical coherence tomography («RTVue-100,» USA. The fundography was carried out using a Nikon NF505‑AF (Japan fundus camera. All patients were examined with a Goldmann lens.Results: Optical coherence tomography was used to evaluate different kinds of peripheral retinal degenerations, such as lattice and snail track degeneration, isolated retinal tears, cystoid retinal degeneration, pathological hyperpigmentation, retinoschisis and cobblestone degeneration. The following morphometric data were studied: dimensions of the lesion (average length, retinal thickness along the edge of the lesion, retinal thickness at the base of the lesion and the vitreoretinal interface.Conclusion: Optical coherence tomography is a promising in vivo visualization method which is useful in evaluation of peripheral retinal degenerations, vitreoretinal adhesions and tractions. It also provides a comprehensive protocolling system and monitoring. It will enable ophthalmologists to better define laser and surgical treatment indications and evaluate therapy effectiveness.

  2. Optical coherent tomography in diagnoses of peripheral retinal degenarations

    Directory of Open Access Journals (Sweden)

    O. G. Pozdeyeva

    2014-07-01

    Full Text Available Purpose: Studying the capabilities of optical coherence tomography (RTVue-100, OPTOVUE, USA in evaluation of peripheral retinal degenerations, vitreoretinal adhesions, adjacent vitreous body as well as measurement of morphometric data.Methods: The study included 189 patients (239 eyes with peripheral retinal degeneration. 77 men and 112 women aged 18 to 84 underwent an ophthalmologic examination since November 2012 until October 2013. The peripheral retina was visualized with the help of optical coherence tomography («RTVue-100,» USA. The fundography was carried out using a Nikon NF505‑AF (Japan fundus camera. All patients were examined with a Goldmann lens.Results: Optical coherence tomography was used to evaluate different kinds of peripheral retinal degenerations, such as lattice and snail track degeneration, isolated retinal tears, cystoid retinal degeneration, pathological hyperpigmentation, retinoschisis and cobblestone degeneration. The following morphometric data were studied: dimensions of the lesion (average length, retinal thickness along the edge of the lesion, retinal thickness at the base of the lesion and the vitreoretinal interface.Conclusion: Optical coherence tomography is a promising in vivo visualization method which is useful in evaluation of peripheral retinal degenerations, vitreoretinal adhesions and tractions. It also provides a comprehensive protocolling system and monitoring. It will enable ophthalmologists to better define laser and surgical treatment indications and evaluate therapy effectiveness.

  3. Living with vision loss

    Science.gov (United States)

    Diabetes - vision loss; Retinopathy - vision loss; Low vision; Blindness - vision loss ... of visual aids. Some options include: Magnifiers High power reading glasses Devices that make it easier to ...

  4. Portable electronic vision enhancement systems in comparison with optical magnifiers for near vision activities: an economic evaluation alongside a randomized crossover trial.

    Science.gov (United States)

    Bray, Nathan; Brand, Andrew; Taylor, John; Hoare, Zoe; Dickinson, Christine; Edwards, Rhiannon T

    2017-08-01

    To determine the incremental cost-effectiveness of portable electronic vision enhancement system (p-EVES) devices compared with optical low vision aids (LVAs), for improving near vision visual function, quality of life and well-being of people with a visual impairment. An AB/BA randomized crossover trial design was used. Eighty-two participants completed the study. Participants were current users of optical LVAs who had not tried a p-EVES device before and had a stable visual impairment. The trial intervention was the addition of a p-EVES device to the participant's existing optical LVA(s) for 2 months, and the control intervention was optical LVA use only, for 2 months. Cost-effectiveness and cost-utility analyses were conducted from a societal perspective. The mean cost of the p-EVES intervention was £448. Carer costs were £30 (4.46 hr) less for the p-EVES intervention compared with the LVA only control. The mean difference in total costs was £417. Bootstrapping gave an incremental cost-effectiveness ratio (ICER) of £736 (95% CI £481 to £1525) for a 7% improvement in near vision visual function. Cost per quality-adjusted life year (QALY) ranged from £56 991 (lower 95% CI = £19 801) to £66 490 (lower 95% CI = £23 055). Sensitivity analysis varying the commercial price of the p-EVES device reduced ICERs by up to 75%, with cost per QALYs falling below £30 000. Portable electronic vision enhancement system (p-EVES) devices are likely to be a cost-effective use of healthcare resources for improving near vision visual function, but this does not translate into cost-effective improvements in quality of life, capability or well-being. © 2016 The Authors. Acta Ophthalmologica published by John Wiley & Sons Ltd on behalf of Acta Ophthalmologica Scandinavica Foundation and European Association for Vision & Eye Research.

  5. A child's vision.

    Science.gov (United States)

    Nye, Christina

    2014-06-01

    Implementing standard vision screening techniques in the primary care practice is the most effective means to detect children with potential vision problems at an age when the vision loss may be treatable. A critical period of vision development occurs in the first few weeks of life; thus, it is imperative that serious problems are detected at this time. Although it is not possible to quantitate an infant's vision, evaluating ocular health appropriately can mean the difference between sight and blindness and, in the case of retinoblastoma, life or death. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Effects of visual skills training, vision coaching and sports vision ...

    African Journals Online (AJOL)

    The purpose of this study was to determine the effectiveness of three different approaches to improving sports performance through improvements in “sports vision:” (1) a visual skills training programme, (2) traditional vision coaching sessions, and (3) a multi-disciplinary approach identified as sports vision dynamics.

  7. Color vision test

    Science.gov (United States)

    ... present from birth) color vision problems: Achromatopsia -- complete color blindness , seeing only shades of gray Deuteranopia -- difficulty telling ... Vision test - color; Ishihara color vision test Images Color blindness tests References Bowling B. Hereditary fundus dystrophies. In: ...

  8. Impairments to Vision

    Science.gov (United States)

    ... an external Non-Government web site. Impairments to Vision Normal Vision Diabetic Retinopathy Age-related Macular Degeneration In this ... pictures, fixate on the nose to simulate the vision loss. In diabetic retinopathy, the blood vessels in ...

  9. Data-Fusion for a Vision-Aided Radiological Detection System: Sensor dependence and Source Tracking

    Science.gov (United States)

    Stadnikia, Kelsey; Martin, Allan; Henderson, Kristofer; Koppal, Sanjeev; Enqvist, Andreas

    2018-01-01

    The University of Florida is taking a multidisciplinary approach to fuse the data between 3D vision sensors and radiological sensors in hopes of creating a system capable of not only detecting the presence of a radiological threat, but also tracking it. The key to developing such a vision-aided radiological detection system, lies in the count rate being inversely dependent on the square of the distance. Presented in this paper are the results of the calibration algorithm used to predict the location of the radiological detectors based on 3D distance from the source to the detector (vision data) and the detectors count rate (radiological data). Also presented are the results of two correlation methods used to explore source tracking.

  10. Vision Lab

    Data.gov (United States)

    Federal Laboratory Consortium — The Vision Lab personnel perform research, development, testing and evaluation of eye protection and vision performance. The lab maintains and continues to develop...

  11. Multi-Center Evaluation of the Automated Immunohematology Instrument, the ORTHO VISION Analyzer.

    Science.gov (United States)

    Aysola, Agnes; Wheeler, Leslie; Brown, Richard; Denham, Rebecca; Colavecchia, Connie; Pavenski, Katerina; Krok, Elizabeth; Hayes, Chelsea; Klapper, Ellen

    2017-02-01

    ORTHO VISION Analyzer (Vision), is an immunohematology instrument using ID-MT gel card technology with digital image processing. It has a continuous, random sample access with STAT priority processing. The efficiency and ease of operation of Vision was evaluated at 5 medical centers. De-identified patient samples were tested on the ORTHO ProVue Analyzer (ProVue) and repeated on the Vision mimicking the daily workload pattern. Turnaround times (TAT) were collected and compared. Operators rated key features of the analyzer on a scale of 1 to 5. A total of 507 samples were tested on both instruments at the 5 trial sites. The mean TAT (SD) were 31.6 minutes (5.5) with Vision and 35.7 minutes (8.4) with ProVue, which renders a 12% reduction. Type and screens were performed on 381 samples; the mean TAT (SD) was 32.2 minutes (4.5) with Vision and 37.0 minutes (7.4) with ProVue. Antibody identification with eleven panel cells was performed on 134 samples on Vision; TAT (SD) was 43.2 minutes (8.3). The installation, training, configuration, maintenance and validation processes are all streamlined to provide a short implementation time. The average rating of main functions by the operators was 4.1 to 4.8. Opportunities for improvement, such as flexibility with editing QC results, maintenance schedule, and printing options were identified. The capabilities to perform serial dilutions, to accept pediatric tubes, and review results by e-Connectivity are enhancements over the ProVue. Vision provides shorter TAT compared to ProVue. Every site described a positive experience using Vision. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  12. From spectral information to animal colour vision: experiments and concepts.

    Science.gov (United States)

    Kelber, Almut; Osorio, Daniel

    2010-06-07

    Many animals use the spectral distribution of light to guide behaviour, but whether they have colour vision has been debated for over a century. Our strong subjective experience of colour and the fact that human vision is the paradigm for colour science inevitably raises the question of how we compare with other species. This article outlines four grades of 'colour vision' that can be related to the behavioural uses of spectral information, and perhaps to the underlying mechanisms. In the first, even without an (image-forming) eye, simple organisms can compare photoreceptor signals to locate a desired light environment. At the next grade, chromatic mechanisms along with spatial vision guide innate preferences for objects such as food or mates; this is sometimes described as wavelength-specific behaviour. Here, we compare the capabilities of di- and trichromatic vision, and ask why some animals have more than three spectral types of receptors. Behaviours guided by innate preferences are then distinguished from a grade that allows learning, in part because the ability to learn an arbitrary colour is evidence for a neural representation of colour. The fourth grade concerns colour appearance rather than colour difference: for instance, the distinction between hue and saturation, and colour categorization. These higher-level phenomena are essential to human colour perception but poorly known in animals, and we suggest how they can be studied. Finally, we observe that awareness of colour and colour qualia cannot be easily tested in animals.

  13. Robot Vision Library

    Science.gov (United States)

    Howard, Andrew B.; Ansar, Adnan I.; Litwin, Todd E.; Goldberg, Steven B.

    2009-01-01

    The JPL Robot Vision Library (JPLV) provides real-time robot vision algorithms for developers who are not vision specialists. The package includes algorithms for stereo ranging, visual odometry and unsurveyed camera calibration, and has unique support for very wideangle lenses

  14. Visions of Vision: An Exploratory Study of the Role College and University Presidents Play in Developing Institutional Vision

    Science.gov (United States)

    McWade, Jessica C.

    2014-01-01

    This qualitative research explores how college and university presidents engage in the process of developing formal institutional vision. The inquiry identifies roles presidents play in vision development, which is often undertaken as part of strategic-planning initiatives. Two constructs of leadership and institutional vision are used to examine…

  15. Light Vision Color

    Science.gov (United States)

    Valberg, Arne

    2005-04-01

    Light Vision Color takes a well-balanced, interdisciplinary approach to our most important sensory system. The book successfully combines basics in vision sciences with recent developments from different areas such as neuroscience, biophysics, sensory psychology and philosophy. Originally published in 1998 this edition has been extensively revised and updated to include new chapters on clinical problems and eye diseases, low vision rehabilitation and the basic molecular biology and genetics of colour vision. Takes a broad interdisciplinary approach combining basics in vision sciences with the most recent developments in the area Includes an extensive list of technical terms and explanations to encourage student understanding Successfully brings together the most important areas of the subject in to one volume

  16. What Is Low Vision?

    Science.gov (United States)

    ... Your Rights Training Resources Workplace Technology CareerConnect Stories Working as a Senior with Vision Loss For Seniors Age-Related Vision ... Changes Health and Aging Retirement Living Continuing to Work as a Senior with Vision Loss Get Connected About VisionAware Join ...

  17. Static and dynamic postural control in low-vision and normal-vision adults.

    Science.gov (United States)

    Tomomitsu, Mônica S V; Alonso, Angelica Castilho; Morimoto, Eurica; Bobbio, Tatiana G; Greve, Julia M D

    2013-04-01

    This study aimed to evaluate the influence of reduced visual information on postural control by comparing low-vision and normal-vision adults in static and dynamic conditions. Twenty-five low-vision subjects and twenty-five normal sighted adults were evaluated for static and dynamic balance using four protocols: 1) the Modified Clinical Test of Sensory Interaction on Balance on firm and foam surfaces with eyes opened and closed; 2) Unilateral Stance with eyes opened and closed; 3) Tandem Walk; and 4) Step Up/Over. The results showed that the low-vision group presented greater body sway compared with the normal vision during balance on a foam surface (p≤0.001), the Unilateral Stance test for both limbs (p≤0.001), and the Tandem Walk test. The low-vision group showed greater step width (p≤0.001) and slower gait speed (p≤0.004). In the Step Up/Over task, low-vision participants were more cautious in stepping up (right p≤0.005 and left p≤0.009) and in executing the movement (p≤0.001). These findings suggest that visual feedback is crucial for determining balance, especially for dynamic tasks and on foam surfaces. Low-vision individuals had worse postural stability than normal-vision adults in terms of dynamic tests and balance on foam surfaces.

  18. VISION development

    International Nuclear Information System (INIS)

    Hernandez, J.E.; Sherwood, R.J.; Whitman, S.R.

    1994-01-01

    VISION is a flexible and extensible object-oriented programming environment for prototyping computer-vision and pattern-recognition algorithms. This year's effort focused on three major areas: documentation, graphics, and support for new applications

  19. Monocular Vision SLAM for Indoor Aerial Vehicles

    Directory of Open Access Journals (Sweden)

    Koray Çelik

    2013-01-01

    Full Text Available This paper presents a novel indoor navigation and ranging strategy via monocular camera. By exploiting the architectural orthogonality of the indoor environments, we introduce a new method to estimate range and vehicle states from a monocular camera for vision-based SLAM. The navigation strategy assumes an indoor or indoor-like manmade environment whose layout is previously unknown, GPS-denied, representable via energy based feature points, and straight architectural lines. We experimentally validate the proposed algorithms on a fully self-contained microaerial vehicle (MAV with sophisticated on-board image processing and SLAM capabilities. Building and enabling such a small aerial vehicle to fly in tight corridors is a significant technological challenge, especially in the absence of GPS signals and with limited sensing options. Experimental results show that the system is only limited by the capabilities of the camera and environmental entropy.

  20. International Border Management Systems (IBMS) Program : visions and strategies.

    Energy Technology Data Exchange (ETDEWEB)

    McDaniel, Michael; Mohagheghi, Amir Hossein

    2011-02-01

    Sandia National Laboratories (SNL), International Border Management Systems (IBMS) Program is working to establish a long-term border security strategy with United States Central Command (CENTCOM). Efforts are being made to synthesize border security capabilities and technologies maintained at the Laboratories, and coordinate with subject matter expertise from both the New Mexico and California offices. The vision for SNL is to provide science and technology support for international projects and engagements on border security.

  1. Mass Customization as Innovation Driver of International Competitiveness in Peripheral Regional SME Subcontractors

    DEFF Research Database (Denmark)

    Taps, Stig B.; Brunø, Thomas Ditlev; Nielsen, Kjeld

    2014-01-01

    practices that can be exploited as competitive capabilities. This paper suggests that an open network structure demands a transformation of peripheral-located SME subcontractor from traditional customized producer to mass customized producer. Mass customization as an instrument for the transformation...

  2. Transitions between central and peripheral vision create spatial/temporal distortions: a hypothesis concerning the perceived break of the curveball.

    Directory of Open Access Journals (Sweden)

    Arthur Shapiro

    2010-10-01

    Full Text Available The human visual system does not treat all parts of an image equally: the central segments of an image, which fall on the fovea, are processed with a higher resolution than the segments that fall in the visual periphery. Even though the differences between foveal and peripheral resolution are large, these differences do not usually disrupt our perception of seamless visual space. Here we examine a motion stimulus in which the shift from foveal to peripheral viewing creates a dramatic spatial/temporal discontinuity.The stimulus consists of a descending disk (global motion with an internal moving grating (local motion. When observers view the disk centrally, they perceive both global and local motion (i.e., observers see the disk's vertical descent and the internal spinning. When observers view the disk peripherally, the internal portion appears stationary, and the disk appears to descend at an angle. The angle of perceived descent increases as the observer views the stimulus from further in the periphery. We examine the first- and second-order information content in the display with the use of a three-dimensional Fourier analysis and show how our results can be used to describe perceived spatial/temporal discontinuities in real-world situations.The perceived shift of the disk's direction in the periphery is consistent with a model in which foveal processing separates first- and second-order motion information while peripheral processing integrates first- and second-order motion information. We argue that the perceived distortion may influence real-world visual observations. To this end, we present a hypothesis and analysis of the perception of the curveball and rising fastball in the sport of baseball. The curveball is a physically measurable phenomenon: the imbalance of forces created by the ball's spin causes the ball to deviate from a straight line and to follow a smooth parabolic path. However, the curveball is also a perceptual puzzle

  3. Transitions between central and peripheral vision create spatial/temporal distortions: a hypothesis concerning the perceived break of the curveball.

    Science.gov (United States)

    Shapiro, Arthur; Lu, Zhong-Lin; Huang, Chang-Bing; Knight, Emily; Ennis, Robert

    2010-10-13

    The human visual system does not treat all parts of an image equally: the central segments of an image, which fall on the fovea, are processed with a higher resolution than the segments that fall in the visual periphery. Even though the differences between foveal and peripheral resolution are large, these differences do not usually disrupt our perception of seamless visual space. Here we examine a motion stimulus in which the shift from foveal to peripheral viewing creates a dramatic spatial/temporal discontinuity. The stimulus consists of a descending disk (global motion) with an internal moving grating (local motion). When observers view the disk centrally, they perceive both global and local motion (i.e., observers see the disk's vertical descent and the internal spinning). When observers view the disk peripherally, the internal portion appears stationary, and the disk appears to descend at an angle. The angle of perceived descent increases as the observer views the stimulus from further in the periphery. We examine the first- and second-order information content in the display with the use of a three-dimensional Fourier analysis and show how our results can be used to describe perceived spatial/temporal discontinuities in real-world situations. The perceived shift of the disk's direction in the periphery is consistent with a model in which foveal processing separates first- and second-order motion information while peripheral processing integrates first- and second-order motion information. We argue that the perceived distortion may influence real-world visual observations. To this end, we present a hypothesis and analysis of the perception of the curveball and rising fastball in the sport of baseball. The curveball is a physically measurable phenomenon: the imbalance of forces created by the ball's spin causes the ball to deviate from a straight line and to follow a smooth parabolic path. However, the curveball is also a perceptual puzzle because batters often

  4. The free electron laser: a system capable of determining the gold standard in laser vision correction

    International Nuclear Information System (INIS)

    Fowler, W. Craig; Rose, John G.; Chang, Daniel H.; Proia, Alan D.

    1999-01-01

    Introduction. In laser vision correction surgery, lasers are generally utilized based on their beam-tissue interactions and corneal absorption characteristics. Therefore, the free electron laser, with its ability to provide broad wavelength tunability, is a unique research tool for investigating wavelengths of possible corneal ablation. Methods. Mark III free electron laser wavelengths between 2.94 and 6.7 μm were delivered in serial 0.1 μm intervals to corneas of freshly enucleated porcine globes. Collateral damage, ablation depth, and ablation diameter were measured in histologic sections. Results. The least collateral damage (12-13 μm) was demonstrated at three wavelengths: 6.0, 6.1 (amide I), and 6.3 μm. Minimal collateral damage (15 μm) was noted at 2.94 μm (OH-stretch) and at 6.2 μm. Slightly greater collateral damage was noted at 6.45 μm (amide II), as well as at the 5.5-5.7 μm range, but this was still substantially less than the collateral damage noted at the other wavelengths tested. Conclusions. Our results suggest that select mid-infrared wavelengths have potential for keratorefractive surgery and warrant additional study. Further, the free electron laser's ability to allow parameter adjustment in the far-ultraviolet spectrum may provide unprecedented insights toward establishing the gold-standard parameters for laser vision correction surgery

  5. Comparison of a multispectral vision system and a colorimeter for the assessment of meat color

    DEFF Research Database (Denmark)

    Trinderup, Camilla Himmelstrup; Dahl, Anders Bjorholm; Jensen, Kirsten

    2015-01-01

    The color assessment ability of a multispectral vision system is investigated by a comparison study with color measurements from a traditional colorimeter. The experiment involves fresh and processed meat samples. Meat is a complex material; heterogeneous with varying scattering and reflectance...... are equally capable of measuring color. Moreover the vision system provides a more color rich assessment of fresh meat samples with a glossier surface, than the colorimeter. Careful studies of the different sources of variation enable an assessment of the order of magnitude of the variability between methods...... accounting for other sources of variation leading to the conclusion that color assessment using a multispectral vision system is superior to traditional colorimeter assessments. (C) 2014 Elsevier Ltd. All rights reserved....

  6. Operational modal analysis on a VAWT in a large wind tunnel using stereo vision technique

    DEFF Research Database (Denmark)

    Najafi, Nadia; Schmidt Paulsen, Uwe

    2017-01-01

    This paper is about development and use of a research based stereo vision system for vibration and operational modal analysis on a parked, 1-kW, 3-bladed vertical axis wind turbine (VAWT), tested in a wind tunnel at high wind. Vibrations were explored experimentally by tracking small deflections...... of the markers on the structure with two cameras, and also numerically, to study structural vibrations in an overall objective to investigate challenges and to prove the capability of using stereo vision. Two high speed cameras provided displacement measurements at no wind speed interference. The displacement...

  7. Eye movements of patients with tunnel vision while walking.

    Science.gov (United States)

    Vargas-Martín, Fernando; Peli, Eli

    2006-12-01

    To determine how severe peripheral field loss (PFL) affects the dispersion of eye movements relative to the head in patients walking in real environments. This information should help to define the visual field and clearance requirements for head-mounted mobility visual aids. Eye positions relative to the head were recorded in five patients with retinitis pigmentosa who had less than 15 degrees of visual field and in three normally sighted people, each walking in varied environments for more than 30 minutes. The eye-position recorder was made portable by modifying a head-mounted system (ISCAN, Burlington, MA). Custom data processing was implemented, to reject unreliable data. Sample standard deviations of eye position (dispersion) were compared across subject groups and environments. The patients with PFL exhibited narrower horizontal eye-position dispersions than did the normally sighted subjects (9.4 degrees vs. 14.2 degrees , P vision information. Their horizontal scanning was actually reduced, possibly because of lack of peripheral stimulation. The results suggest that a field of view as wide as 40 degrees may be needed for closed (immersive) head-mounted mobility aids, whereas a much narrower display, perhaps as narrow as 20 degrees , may be sufficient with an open design.

  8. Functionality and basic capabilities of preschool children with Down syndrome and Autism spectrum disorders

    Directory of Open Access Journals (Sweden)

    A. M. Kazmin

    2013-08-01

    Full Text Available We have examined and compared the status of functionality and basic capabilities (gross and fine motor, visual and auditory basic skills, basic capabilities to interaction, communication and education of preschoolers with Down syndrome (21 children, age 69 ± 20 months and Autism spectrum disorders (21 children, age 61 ± 14 months with the questionnaires F-07 and "Basic capabilities ". Have been revealed the expressed variability of the level of functionality and reduced patterns of the basic capabilities for both groups of children. Have been demonstrated a significant strong positive connections between the levels of functionality and basic capabilities, except for the motor capabilities, in both groups. The reduction structures of the basic capabilities of the children with Down syndrome and Autism spectrum disorders were found to be different: first were more successful in vision, hearing, the interaction and communication, and second in a fine motor skills.

  9. Barriers to accessing low vision services.

    Science.gov (United States)

    Pollard, Tamara L; Simpson, John A; Lamoureux, Ecosse L; Keeffe, Jill E

    2003-07-01

    To investigate barriers to accessing low vision services in Australia. Adults with a vision impairment (vision difficulties, duration of vision loss and satisfaction with vision and also examined issues of awareness of low vision services and referral to services. Focus groups were also conducted with vision impaired (Vision Australia Foundation. The discussions were recorded and transcribed. The questionnaire revealed that referral to low vision services was associated with a greater degree of vision loss (p = 0.002) and a greater self-perception of low vision (p = 0.005) but that referral was not associated with satisfaction (p = 0.144) or difficulties related to vision (p = 0.169). Participants with mild and moderate vision impairment each reported similar levels of difficulties with daily activities and satisfaction with their vision (p > 0.05). However, there was a significant difference in the level of difficulties experienced with daily activities between those with mild-moderate and severe vision impairment (p low vision services related to awareness of services among the general public and eye care professionals, understanding of low vision and the services available, acceptance of low vision, the referral process, and transport. In addition to the expected difficulties with lack of awareness of services by people with low vision, many people do not understand what the services provide and do not identify themselves as having low vision. Knowledge of these barriers, from the perspective of people with low vision, can now be used to guide the development and content of future health-promotion campaigns.

  10. Computer Vision System For Locating And Identifying Defects In Hardwood Lumber

    Science.gov (United States)

    Conners, Richard W.; Ng, Chong T.; Cho, Tai-Hoon; McMillin, Charles W.

    1989-03-01

    This paper describes research aimed at developing an automatic cutup system for use in the rough mills of the hardwood furniture and fixture industry. In particular, this paper describes attempts to create the vision system that will power this automatic cutup system. There are a number of factors that make the development of such a vision system a challenge. First there is the innate variability of the wood material itself. No two species look exactly the same, in fact, they can have a significant visual difference in appearance among species. Yet a truly robust vision system must be able to handle a variety of such species, preferably with no operator intervention required when changing from one species to another. Secondly, there is a good deal of variability in the definition of what constitutes a removable defect. The hardwood furniture and fixture industry is diverse in the nature of the products that it makes. The products range from hardwood flooring to fancy hardwood furniture, from simple mill work to kitchen cabinets. Thus depending on the manufacturer, the product, and the quality of the product the nature of what constitutes a removable defect can and does vary. The vision system must be such that it can be tailored to meet each of these unique needs, preferably without any additional program modifications. This paper will describe the vision system that has been developed. It will assess the current system capabilities, and it will discuss the directions for future research. It will be argued that artificial intelligence methods provide a natural mechanism for attacking this computer vision application.

  11. Progress in computer vision.

    Science.gov (United States)

    Jain, A. K.; Dorai, C.

    Computer vision has emerged as a challenging and important area of research, both as an engineering and a scientific discipline. The growing importance of computer vision is evident from the fact that it was identified as one of the "Grand Challenges" and also from its prominent role in the National Information Infrastructure. While the design of a general-purpose vision system continues to be elusive machine vision systems are being used successfully in specific application elusive, machine vision systems are being used successfully in specific application domains. Building a practical vision system requires a careful selection of appropriate sensors, extraction and integration of information from available cues in the sensed data, and evaluation of system robustness and performance. The authors discuss and demonstrate advantages of (1) multi-sensor fusion, (2) combination of features and classifiers, (3) integration of visual modules, and (IV) admissibility and goal-directed evaluation of vision algorithms. The requirements of several prominent real world applications such as biometry, document image analysis, image and video database retrieval, and automatic object model construction offer exciting problems and new opportunities to design and evaluate vision algorithms.

  12. Development of a Compact Range-gated Vision System to Monitor Structures in Low-visibility Environments

    International Nuclear Information System (INIS)

    Ahn, Yong-Jin; Park, Seung-Kyu; Baik, Sung-Hoon; Kim, Dong-Lyul; Choi, Young-Soo; Jeong, Kyung-Min

    2015-01-01

    Image acquisition in disaster area or radiation area of nuclear industry is an important function for safety inspection and preparing appropriate damage control plans. So, automatic vision system to monitor structures and facilities in blurred smoking environments such as the places of a fire and detonation is essential. Vision systems can't acquire an image when the illumination light is blocked by disturbance materials, such as smoke, fog and dust. To overcome the imaging distortion caused by obstacle materials, robust vision systems should have extra-functions, such as active illumination through disturbance materials. One of active vision system is a range-gated imaging system. The vision system based on the range-gated imaging system can acquire image data from the blurred and darken light environments. Range-gated imaging (RGI) is a direct active visualization technique using a highly sensitive image sensor and a high intensity illuminant. Currently, the range-gated imaging technique providing 2D and range image data is one of emerging active vision technologies. The range-gated imaging system gets vision information by summing time sliced vision images. In the RGI system, a high intensity illuminant illuminates for ultra-short time and a highly sensitive image sensor is gated by ultra-short exposure time to only get the illumination light. Here, the illuminant illuminates objects by flashing strong light through disturbance materials, such as smoke particles and dust particles. In contrast to passive conventional vision systems, the RGI active vision technology enables operation even in harsh environments like low-visibility smoky environment. In this paper, a compact range-gated vision system is developed to monitor structures in low-visibility environment. The system consists of illumination light, a range-gating camera and a control computer. Visualization experiments are carried out in low-visibility foggy environment to see imaging capability

  13. Development of a Compact Range-gated Vision System to Monitor Structures in Low-visibility Environments

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Yong-Jin; Park, Seung-Kyu; Baik, Sung-Hoon; Kim, Dong-Lyul; Choi, Young-Soo; Jeong, Kyung-Min [KAERI, Daejeon (Korea, Republic of)

    2015-05-15

    Image acquisition in disaster area or radiation area of nuclear industry is an important function for safety inspection and preparing appropriate damage control plans. So, automatic vision system to monitor structures and facilities in blurred smoking environments such as the places of a fire and detonation is essential. Vision systems can't acquire an image when the illumination light is blocked by disturbance materials, such as smoke, fog and dust. To overcome the imaging distortion caused by obstacle materials, robust vision systems should have extra-functions, such as active illumination through disturbance materials. One of active vision system is a range-gated imaging system. The vision system based on the range-gated imaging system can acquire image data from the blurred and darken light environments. Range-gated imaging (RGI) is a direct active visualization technique using a highly sensitive image sensor and a high intensity illuminant. Currently, the range-gated imaging technique providing 2D and range image data is one of emerging active vision technologies. The range-gated imaging system gets vision information by summing time sliced vision images. In the RGI system, a high intensity illuminant illuminates for ultra-short time and a highly sensitive image sensor is gated by ultra-short exposure time to only get the illumination light. Here, the illuminant illuminates objects by flashing strong light through disturbance materials, such as smoke particles and dust particles. In contrast to passive conventional vision systems, the RGI active vision technology enables operation even in harsh environments like low-visibility smoky environment. In this paper, a compact range-gated vision system is developed to monitor structures in low-visibility environment. The system consists of illumination light, a range-gating camera and a control computer. Visualization experiments are carried out in low-visibility foggy environment to see imaging capability.

  14. The CCH Vision Stimulation Program for Infants with Low Vision: Preliminary Results.

    Science.gov (United States)

    Leguire, L. E.; And Others

    1992-01-01

    This study evaluated the Columbus (Ohio) Children's Hospital vision stimulation program, involving in-home intervention with 15 visually impaired infants. Comparison with controls indicated benefits of appropriate vision stimulation in increasing the neural foundation for vision and visual-motor function in visually impaired infants. (Author/DB)

  15. Maintaining operational excellence: building capability beyond knowledge transfer

    International Nuclear Information System (INIS)

    Ramjist, S.

    2013-01-01

    This paper describes the issues relating to human resources and maintaining capabilities in an organization. The sustaining elements are: vision and plan for excellence; invest in the plant; invest in human capital; find and fix problems. There is much discussion about knowledge transfer and retention that is mainly focused on technical attributes and proficiency. We are losing more people with the requisite managerial and leadership capability than we can develop and backfill at a Time when our industry is facing increased competition and decreased margins. We are vulnerable because this Increases our dependence on augmented staff for certain key leadership roles. Previous methods for developing people will take too long and does not appeal to current generation. A solution, not the only solution, but the one we have chosen is initial hiring of operators, maintainers and engineers, internal promotion for key roles (FLM, FSOS, Shift Supervisor, Section Manager, ANO) and focus on all three aspects of capability and looking for leadership traits. Look for ambition, drive, initiative and motivation. Identify, separate and stream. Take specific measures to accelerate growth.

  16. Maintaining operational excellence: building capability beyond knowledge transfer

    Energy Technology Data Exchange (ETDEWEB)

    Ramjist, S. [Ontario Power Generation, Darlington Nuclear Generating Station, Bowmanville, Ontario (Canada)

    2013-07-01

    This paper describes the issues relating to human resources and maintaining capabilities in an organization. The sustaining elements are: vision and plan for excellence; invest in the plant; invest in human capital; find and fix problems. There is much discussion about knowledge transfer and retention that is mainly focused on technical attributes and proficiency. We are losing more people with the requisite managerial and leadership capability than we can develop and backfill at a Time when our industry is facing increased competition and decreased margins. We are vulnerable because this Increases our dependence on augmented staff for certain key leadership roles. Previous methods for developing people will take too long and does not appeal to current generation. A solution, not the only solution, but the one we have chosen is initial hiring of operators, maintainers and engineers, internal promotion for key roles (FLM, FSOS, Shift Supervisor, Section Manager, ANO) and focus on all three aspects of capability and looking for leadership traits. Look for ambition, drive, initiative and motivation. Identify, separate and stream. Take specific measures to accelerate growth.

  17. The ontology of vision. The invisible, consciousness of Living matter.

    Directory of Open Access Journals (Sweden)

    Giorgia eFiorio

    2016-02-01

    Full Text Available If I close my eyes, the absence of light activates the peripheral cells devoted to the perception of darkness. The awareness of ‘seeing oneself seeing’ is in its essence a thought, one that is internal to the vision and previous to any object of sight. To this amphibious faculty, the diaphanous color of darkness, Aristotle assigns the principle of knowledge. Vision is a whole perceptual system, not a channel of sense. Functions of vision are interweaved to the texture of human interaction within a terrestrial environment that is in turn contained into the cosmic order. Within the internal resonance of a double reflection, the living being is the transitive host between two orders of scale, both bigger and smaller than the individual and unity. In the perceptual integrative system of human vision, the convergence-divergence of the corporeal presence and the diffraction of its own appearance is the margin. The sensation of being no longer coincides with the breath of life, it does not seems ‘real’ without the trace of some visible evidence and its simultaneous ‘sharing.’ Without a shadow, without an imprint, and destined for multiple invisible witnesses, the numeric copia of the physical presence inhabits the transient memory of our electronic prostheses. A rudimentary ‘visuality’ replaces tangible experience dissipating its meaning and the awareness of being alive. Transversal to the civilizations of the ancient world, through different orders of function and status, the anthropomorphic figuration of archaic sculpture questions the idea of Being. Ancient statues do not appear in order to be visible as artworks, but rather to exist. The awareness of human finiteness seals the compulsion to ‘give body’ to an invisible apparition that shapes the figuration of Being as the corporeal expression of an ontogenetic waking of human consciousness.Subject and object, the term humanum fathoms the relationship between matter and its living

  18. Smartphones as image processing systems for prosthetic vision.

    Science.gov (United States)

    Zapf, Marc P; Matteucci, Paul B; Lovell, Nigel H; Suaning, Gregg J

    2013-01-01

    The feasibility of implants for prosthetic vision has been demonstrated by research and commercial organizations. In most devices, an essential forerunner to the internal stimulation circuit is an external electronics solution for capturing, processing and relaying image information as well as extracting useful features from the scene surrounding the patient. The capabilities and multitude of image processing algorithms that can be performed by the device in real-time plays a major part in the final quality of the prosthetic vision. It is therefore optimal to use powerful hardware yet to avoid bulky, straining solutions. Recent publications have reported of portable single-board computers fast enough for computationally intensive image processing. Following the rapid evolution of commercial, ultra-portable ARM (Advanced RISC machine) mobile devices, the authors investigated the feasibility of modern smartphones running complex face detection as external processing devices for vision implants. The role of dedicated graphics processors in speeding up computation was evaluated while performing a demanding noise reduction algorithm (image denoising). The time required for face detection was found to decrease by 95% from 2.5 year old to recent devices. In denoising, graphics acceleration played a major role, speeding up denoising by a factor of 18. These results demonstrate that the technology has matured sufficiently to be considered as a valid external electronics platform for visual prosthetic research.

  19. Machine Vision Handbook

    CERN Document Server

    2012-01-01

    The automation of visual inspection is becoming more and more important in modern industry as a consistent, reliable means of judging the quality of raw materials and manufactured goods . The Machine Vision Handbook  equips the reader with the practical details required to engineer integrated mechanical-optical-electronic-software systems. Machine vision is first set in the context of basic information on light, natural vision, colour sensing and optics. The physical apparatus required for mechanized image capture – lenses, cameras, scanners and light sources – are discussed followed by detailed treatment of various image-processing methods including an introduction to the QT image processing system. QT is unique to this book, and provides an example of a practical machine vision system along with extensive libraries of useful commands, functions and images which can be implemented by the reader. The main text of the book is completed by studies of a wide variety of applications of machine vision in insp...

  20. Development of a Vision-Based Situational Awareness Capability for Unmanned Surface Vessels

    Science.gov (United States)

    2017-09-01

    camera), which is similar to the movement of the ship in the electro-optics (EO) video imagery. An image of the model representing the ship with a...with both color video imagery and infrared video imagery, and the results obtained from processing the images demonstrated the viability of using this...situational awareness capability, which is required to achieve autonomous navigation. The algorithm was tested with both color video imagery and infrared

  1. Direct Conversion of Human Fibroblasts into Schwann Cells that Facilitate Regeneration of Injured Peripheral Nerve In Vivo.

    Science.gov (United States)

    Sowa, Yoshihiro; Kishida, Tsunao; Tomita, Koichi; Yamamoto, Kenta; Numajiri, Toshiaki; Mazda, Osam

    2017-04-01

    Schwann cells (SCs) play pivotal roles in the maintenance and regeneration of the peripheral nervous system. Although transplantation of SCs enhances repair of experimentally damaged peripheral and central nerve tissues, it is difficult to prepare a sufficient number of functional SCs for transplantation therapy without causing adverse events for the donor. Here, we generated functional SCs by somatic cell reprogramming procedures and demonstrated their capability to promote peripheral nerve regeneration. Normal human fibroblasts were phenotypically converted into SCs by transducing SOX10 and Krox20 genes followed by culturing for 10 days resulting in approximately 43% directly converted Schwann cells (dSCs). The dSCs expressed SC-specific proteins, secreted neurotrophic factors, and induced neuronal cells to extend neurites. The dSCs also displayed myelin-forming capability both in vitro and in vivo. Moreover, transplantation of the dSCs into the transected sciatic nerve in mice resulted in significantly accelerated regeneration of the nerve and in improved motor function at a level comparable to that with transplantation of the SCs obtained from a peripheral nerve. The dSCs induced by our procedure may be applicable for novel regeneration therapy for not only peripheral nerve injury but also for central nerve damage and for neurodegenerative disorders related to SC dysfunction. Stem Cells Translational Medicine 2017;6:1207-1216. © 2017 The Authors Stem Cells Translational Medicine published by Wiley Periodicals, Inc. on behalf of AlphaMed Press.

  2. Vision restoration after brain and retina damage: the "residual vision activation theory".

    Science.gov (United States)

    Sabel, Bernhard A; Henrich-Noack, Petra; Fedorov, Anton; Gall, Carolin

    2011-01-01

    Vision loss after retinal or cerebral visual injury (CVI) was long considered to be irreversible. However, there is considerable potential for vision restoration and recovery even in adulthood. Here, we propose the "residual vision activation theory" of how visual functions can be reactivated and restored. CVI is usually not complete, but some structures are typically spared by the damage. They include (i) areas of partial damage at the visual field border, (ii) "islands" of surviving tissue inside the blind field, (iii) extrastriate pathways unaffected by the damage, and (iv) downstream, higher-level neuronal networks. However, residual structures have a triple handicap to be fully functional: (i) fewer neurons, (ii) lack of sufficient attentional resources because of the dominant intact hemisphere caused by excitation/inhibition dysbalance, and (iii) disturbance in their temporal processing. Because of this resulting activation loss, residual structures are unable to contribute much to everyday vision, and their "non-use" further impairs synaptic strength. However, residual structures can be reactivated by engaging them in repetitive stimulation by different means: (i) visual experience, (ii) visual training, or (iii) noninvasive electrical brain current stimulation. These methods lead to strengthening of synaptic transmission and synchronization of partially damaged structures (within-systems plasticity) and downstream neuronal networks (network plasticity). Just as in normal perceptual learning, synaptic plasticity can improve vision and lead to vision restoration. This can be induced at any time after the lesion, at all ages and in all types of visual field impairments after retinal or brain damage (stroke, neurotrauma, glaucoma, amblyopia, age-related macular degeneration). If and to what extent vision restoration can be achieved is a function of the amount of residual tissue and its activation state. However, sustained improvements require repetitive

  3. Filtering and polychromatic vision in mantis shrimps: themes in visible and ultraviolet vision.

    Science.gov (United States)

    Cronin, Thomas W; Bok, Michael J; Marshall, N Justin; Caldwell, Roy L

    2014-01-01

    Stomatopod crustaceans have the most complex and diverse assortment of retinal photoreceptors of any animals, with 16 functional classes. The receptor classes are subdivided into sets responsible for ultraviolet vision, spatial vision, colour vision and polarization vision. Many of these receptor classes are spectrally tuned by filtering pigments located in photoreceptors or overlying optical elements. At visible wavelengths, carotenoproteins or similar substances are packed into vesicles used either as serial, intrarhabdomal filters or lateral filters. A single retina may contain a diversity of these filtering pigments paired with specific photoreceptors, and the pigments used vary between and within species both taxonomically and ecologically. Ultraviolet-filtering pigments in the crystalline cones serve to tune ultraviolet vision in these animals as well, and some ultraviolet receptors themselves act as birefringent filters to enable circular polarization vision. Stomatopods have reached an evolutionary extreme in their use of filter mechanisms to tune photoreception to habitat and behaviour, allowing them to extend the spectral range of their vision both deeper into the ultraviolet and further into the red.

  4. Micro Vision

    OpenAIRE

    Ohba, Kohtaro; Ohara, Kenichi

    2007-01-01

    In the field of the micro vision, there are few researches compared with macro environment. However, applying to the study result for macro computer vision technique, you can measure and observe the micro environment. Moreover, based on the effects of micro environment, it is possible to discovery the new theories and new techniques.

  5. Vision communications based on LED array and imaging sensor

    Science.gov (United States)

    Yoo, Jong-Ho; Jung, Sung-Yoon

    2012-11-01

    In this paper, we propose a brand new communication concept, called as "vision communication" based on LED array and image sensor. This system consists of LED array as a transmitter and digital device which include image sensor such as CCD and CMOS as receiver. In order to transmit data, the proposed communication scheme simultaneously uses the digital image processing and optical wireless communication scheme. Therefore, the cognitive communication scheme is possible with the help of recognition techniques used in vision system. By increasing data rate, our scheme can use LED array consisting of several multi-spectral LEDs. Because arranged each LED can emit multi-spectral optical signal such as visible, infrared and ultraviolet light, the increase of data rate is possible similar to WDM and MIMO skills used in traditional optical and wireless communications. In addition, this multi-spectral capability also makes it possible to avoid the optical noises in communication environment. In our vision communication scheme, the data packet is composed of Sync. data and information data. Sync. data is used to detect the transmitter area and calibrate the distorted image snapshots obtained by image sensor. By making the optical rate of LED array be same with the frame rate (frames per second) of image sensor, we can decode the information data included in each image snapshot based on image processing and optical wireless communication techniques. Through experiment based on practical test bed system, we confirm the feasibility of the proposed vision communications based on LED array and image sensor.

  6. Computer vision system in real-time for color determination on flat surface food

    Directory of Open Access Journals (Sweden)

    Erick Saldaña

    2013-03-01

    Full Text Available Artificial vision systems also known as computer vision are potent quality inspection tools, which can be applied in pattern recognition for fruits and vegetables analysis. The aim of this research was to design, implement and calibrate a new computer vision system (CVS in real-time for the color measurement on flat surface food. For this purpose was designed and implemented a device capable of performing this task (software and hardware, which consisted of two phases: a image acquisition and b image processing and analysis. Both the algorithm and the graphical interface (GUI were developed in Matlab. The CVS calibration was performed using a conventional colorimeter (Model CIEL* a* b*, where were estimated the errors of the color parameters: eL* = 5.001%, and ea* = 2.287%, and eb* = 4.314 % which ensure adequate and efficient automation application in industrial processes in the quality control in the food industry sector.

  7. Computer vision system in real-time for color determination on flat surface food

    Directory of Open Access Journals (Sweden)

    Erick Saldaña

    2013-01-01

    Full Text Available Artificial vision systems also known as computer vision are potent quality inspection tools, which can be applied in pattern recognition for fruits and vegetables analysis. The aim of this research was to design, implement and calibrate a new computer vision system (CVS in real - time f or the color measurement on flat surface food. For this purpose was designed and implemented a device capable of performing this task (software and hardware, which consisted of two phases: a image acquisition and b image processing and analysis. Both th e algorithm and the graphical interface (GUI were developed in Matlab. The CVS calibration was performed using a conventional colorimeter (Model CIEL* a* b*, where were estimated the errors of the color parameters: e L* = 5.001%, and e a* = 2.287%, and e b* = 4.314 % which ensure adequate and efficient automation application in industrial processes in the quality control in the food industry sector.

  8. Research on robot navigation vision sensor based on grating projection stereo vision

    Science.gov (United States)

    Zhang, Xiaoling; Luo, Yinsheng; Lin, Yuchi; Zhu, Lei

    2016-10-01

    A novel visual navigation method based on grating projection stereo vision for mobile robot in dark environment is proposed. This method is combining with grating projection profilometry of plane structured light and stereo vision technology. It can be employed to realize obstacle detection, SLAM (Simultaneous Localization and Mapping) and vision odometry for mobile robot navigation in dark environment without the image match in stereo vision technology and without phase unwrapping in the grating projection profilometry. First, we research the new vision sensor theoretical, and build geometric and mathematical model of the grating projection stereo vision system. Second, the computational method of 3D coordinates of space obstacle in the robot's visual field is studied, and then the obstacles in the field is located accurately. The result of simulation experiment and analysis shows that this research is useful to break the current autonomous navigation problem of mobile robot in dark environment, and to provide the theoretical basis and exploration direction for further study on navigation of space exploring robot in the dark and without GPS environment.

  9. Range-Image Acquisition for Discriminated Objects in a Range-gated Robot Vision System

    Energy Technology Data Exchange (ETDEWEB)

    Park, Seung-Kyu; Ahn, Yong-Jin; Park, Nak-Kyu; Baik, Sung-Hoon; Choi, Young-Soo; Jeong, Kyung-Min [KAERI, Daejeon (Korea, Republic of)

    2015-05-15

    The imaging capability of a surveillance vision system from harsh low-visibility environments such as in fire and detonation areas is a key function to monitor the safety of the facilities. 2D and range image data acquired from low-visibility environment are important data to assess the safety and prepare appropriate countermeasures. Passive vision systems, such as conventional camera and binocular stereo vision systems usually cannot acquire image information when the reflected light is highly scattered and absorbed by airborne particles such as fog. In addition, the image resolution captured through low-density airborne particles is decreased because the image is blurred and dimmed by the scattering, emission and absorption. Active vision systems, such as structured light vision and projected stereo vision are usually more robust for harsh environment than passive vision systems. However, the performance is considerably decreased in proportion to the density of the particles. The RGI system provides 2D and range image data from several RGI images and it moreover provides clear images from low-visibility fog and smoke environment by using the sum of time-sliced images. Nowadays, the Range-gated (RG) imaging is an emerging technology in the field of surveillance for security applications, especially in the visualization of invisible night and fog environment. Although RGI viewing was discovered in the 1960's, this technology is, nowadays becoming more applicable by virtue of the rapid development of optical and sensor technologies. Especially, this system can be adopted in robot-vision system by virtue of its compact portable configuration. In contrast to passive vision systems, this technology enables operation even in harsh environments like fog and smoke. During the past decades, several applications of this technology have been applied in target recognition and in harsh environments, such as fog, underwater vision. Also, this technology has been

  10. Range-Image Acquisition for Discriminated Objects in a Range-gated Robot Vision System

    International Nuclear Information System (INIS)

    Park, Seung-Kyu; Ahn, Yong-Jin; Park, Nak-Kyu; Baik, Sung-Hoon; Choi, Young-Soo; Jeong, Kyung-Min

    2015-01-01

    The imaging capability of a surveillance vision system from harsh low-visibility environments such as in fire and detonation areas is a key function to monitor the safety of the facilities. 2D and range image data acquired from low-visibility environment are important data to assess the safety and prepare appropriate countermeasures. Passive vision systems, such as conventional camera and binocular stereo vision systems usually cannot acquire image information when the reflected light is highly scattered and absorbed by airborne particles such as fog. In addition, the image resolution captured through low-density airborne particles is decreased because the image is blurred and dimmed by the scattering, emission and absorption. Active vision systems, such as structured light vision and projected stereo vision are usually more robust for harsh environment than passive vision systems. However, the performance is considerably decreased in proportion to the density of the particles. The RGI system provides 2D and range image data from several RGI images and it moreover provides clear images from low-visibility fog and smoke environment by using the sum of time-sliced images. Nowadays, the Range-gated (RG) imaging is an emerging technology in the field of surveillance for security applications, especially in the visualization of invisible night and fog environment. Although RGI viewing was discovered in the 1960's, this technology is, nowadays becoming more applicable by virtue of the rapid development of optical and sensor technologies. Especially, this system can be adopted in robot-vision system by virtue of its compact portable configuration. In contrast to passive vision systems, this technology enables operation even in harsh environments like fog and smoke. During the past decades, several applications of this technology have been applied in target recognition and in harsh environments, such as fog, underwater vision. Also, this technology has been

  11. The influence of active vision on the exoskeleton of intelligent agents

    Science.gov (United States)

    Smith, Patrice; Terry, Theodore B.

    2016-04-01

    Chameleonization occurs when a self-learning autonomous mobile system's (SLAMR) active vision scans the surface of which it is perched causing the exoskeleton to changes colors exhibiting a chameleon effect. Intelligent agents having the ability to adapt to their environment and exhibit key survivability characteristics of its environments would largely be due in part to the use of active vision. Active vision would allow the intelligent agent to scan its environment and adapt as needed in order to avoid detection. The SLAMR system would have an exoskeleton, which would change, based on the surface it was perched on; this is known as the "chameleon effect." Not in the common sense of the term, but from the techno-bio inspired meaning as addressed in our previous paper. Active vision, utilizing stereoscopic color sensing functionality would enable the intelligent agent to scan an object within its close proximity, determine the color scheme, and match it; allowing the agent to blend with its environment. Through the use of its' optical capabilities, the SLAMR system would be able to further determine its position, taking into account spatial and temporal correlation and spatial frequency content of neighboring structures further ensuring successful background blending. The complex visual tasks of identifying objects, using edge detection, image filtering, and feature extraction are essential for an intelligent agent to gain additional knowledge about its environmental surroundings.

  12. Automated cutting in the food industry using computer vision

    KAUST Repository

    Daley, Wayne D R

    2012-01-01

    The processing of natural products has posed a significant problem to researchers and developers involved in the development of automation. The challenges have come from areas such as sensing, grasping and manipulation, as well as product-specific areas such as cutting and handling of meat products. Meat products are naturally variable and fixed automation is at its limit as far as its ability to accommodate these products. Intelligent automation systems (such as robots) are also challenged, mostly because of a lack of knowledge of the physical characteristic of the individual products. Machine vision has helped to address some of these shortcomings but underperforms in many situations. Developments in sensors, software and processing power are now offering capabilities that will help to make more of these problems tractable. In this chapter we will describe some of the developments that are underway in terms of computer vision for meat product applications, the problems they are addressing and potential future trends. © 2012 Woodhead Publishing Limited All rights reserved.

  13. Chemicals Industry Vision

    Energy Technology Data Exchange (ETDEWEB)

    none,

    1996-12-01

    Chemical industry leaders articulated a long-term vision for the industry, its markets, and its technology in the groundbreaking 1996 document Technology Vision 2020 - The U.S. Chemical Industry. (PDF 310 KB).

  14. Low Vision Tips

    Science.gov (United States)

    ... this page: https://medlineplus.gov/lowvision.html MedlinePlus: Low Vision Tips We are sorry. MedlinePlus no longer maintains the For Low Vision Users page. You will still find health resources ...

  15. Development of dog-like retrieving capability in a ground robot

    Science.gov (United States)

    MacKenzie, Douglas C.; Ashok, Rahul; Rehg, James M.; Witus, Gary

    2013-01-01

    This paper presents the Mobile Intelligence Team's approach to addressing the CANINE outdoor ground robot competition. The competition required developing a robot that provided retrieving capabilities similar to a dog, while operating fully autonomously in unstructured environments. The vision team consisted of Mobile Intelligence, the Georgia Institute of Technology, and Wayne State University. Important computer vision aspects of the project were the ability to quickly learn the distinguishing characteristics of novel objects, searching images for the object as the robot drove a search pattern, identifying people near the robot for safe operations, correctly identify the object among distractors, and localizing the object for retrieval. The classifier used to identify the objects will be discussed, including an analysis of its performance, and an overview of the entire system architecture presented. A discussion of the robot's performance in the competition will demonstrate the system's successes in real-world testing.

  16. Power profiles of single vision and multifocal soft contact lenses.

    Science.gov (United States)

    Wagner, Sandra; Conrad, Fabian; Bakaraju, Ravi C; Fedtke, Cathleen; Ehrmann, Klaus; Holden, Brien A

    2015-02-01

    The purpose of this study was to investigate the optical zone power profile of the most commonly prescribed soft contact lenses to assess their potential impact on peripheral refractive error and hence myopia progression. The optical power profiles of six single vision and ten multifocal contact lenses of five manufacturers in the powers -1.00 D, -3.00 D, and -6.00 D were measured using the SHSOphthalmic (Optocraft GmbH, Erlangen, Germany). Instrument repeatability was also investigated. Instrument repeatability was dependent on the distance from the optical centre, manifesting unreliable data for the central 1mm of the optic zone. Single vision contact lens measurements of -6.00 D lenses revealed omafilcon A having the most negative spherical aberration, lotrafilcon A having the least. Somofilcon A had the highest minus power and lotrafilcon A the biggest deviation in positive direction, relative to their respective labelled powers. Negative spherical aberration occurred for almost all of the multifocal contact lenses, including the centre-distance designs etafilcon A bifocal and omafilcon A multifocal. Lotrafilcon B and balafilcon A seem to rely predominantly on the spherical aberration component to provide multifocality. Power profiles of single vision soft contact lenses varied greatly, many having a negative spherical aberration profile that would exacerbate myopia. Some lens types and powers are affected by large intra-batch variability or power offsets of more than 0.25 dioptres. Evaluation of power profiles of multifocal lenses was derived that provides helpful information for prescribing lenses for presbyopes and progressing myopes. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  17. Review: Familiarity to Vision Rehabilitation Process

    Directory of Open Access Journals (Sweden)

    Nasser Sadegh-Pour

    2006-10-01

    Full Text Available Considering the numbers of low vision patients who have been visited and treated in eye clinics, sometimes there is no exact treatment to increase their visual acuity. Therefore, the necessity to pay attention to vision rehabilitation for them is strongly felt. The aims of this essay are to define vision rehabilitation and its process in relevant centers (called Low Vision Clinic.The statistic of low vision people is reported and the method of collecting data is described. Standard definition, causes of low vision and related diseases (congenital, heredity, acquired… are explained. In addition, low vision aids and role of test and prescription are discussed. Sometimes ophthalmologists and optometrists can not exactly cure patient to raise their V.A because there is no treatment or drug or ordinary glasses. In these cases the clients should refer to low vision clinic and visit low vision specialist on vision rehabilitation process. After primary evaluation they are tested completely and at the end are prescribed proper low vision aid and also provided with advice in relation to career, education role and training techniques especially in children. At the last part of present dissertation, some examples are provided to show effectiveness of vision rehabilitation and low vision aid among the clients in different countries.

  18. Vasculitic peripheral neuropathy

    Directory of Open Access Journals (Sweden)

    Mona Amini

    2014-02-01

    Full Text Available Primary systemic vasculitis in pre-capillary arteries is associated with peripheral neuropathy. In some types of systematic vasculitis about 60 % of patients have peripheral nervous system (PNS involvement. In vasculitic peripheral neuropathies (VPN a necrotizing and inflammatory process leads to narrowing of vasa nervorum lumen and eventually the appearance of ischemic lesions in peripheral nerves. Some features might be suggestive of VPN, like: axonal nerve degeneration, wallerian-like degeneration, and diameter irregularity of nerve. Peripheral nervous system (PNS destruction during systemic vasculitides should be considered, due to its frequency and early occurrence in vasculitis progression. The first line treatment of non systematic VPNs is corticosteroid agents, but these drugs might worsen the VPNs or systemic vasculitis.

  19. Improving environmental performance through unit-level organizational citizenship behaviors for the environment: A capability perspective.

    Science.gov (United States)

    Alt, Elisa; Spitzeck, Heiko

    2016-11-01

    Organizational citizenship behaviors for the environment (OCBEs) are increasingly advocated as a means of complementing formal practices in improving environmental performance. Adopting a capability perspective, we propose that a firm's employee involvement capability translates into environmental performance through the manifestation of unit-level OCBEs, and that this relationship is amplified by a shared vision capability. In a cross-country and multi-industry sample of 170 firms, we find support for our hypotheses, shedding light on contextual determinants of OCBEs, and on how firms may engender a positive relationship between top-down environmental initiatives and bottom-up behaviors. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Head-Mounted Display Technology for Low Vision Rehabilitation and Vision Enhancement

    Science.gov (United States)

    Ehrlich, Joshua R.; Ojeda, Lauro V.; Wicker, Donna; Day, Sherry; Howson, Ashley; Lakshminarayanan, Vasudevan; Moroi, Sayoko E.

    2017-01-01

    Purpose To describe the various types of head-mounted display technology, their optical and human factors considerations, and their potential for use in low vision rehabilitation and vision enhancement. Design Expert perspective. Methods An overview of head-mounted display technology by an interdisciplinary team of experts drawing on key literature in the field. Results Head-mounted display technologies can be classified based on their display type and optical design. See-through displays such as retinal projection devices have the greatest potential for use as low vision aids. Devices vary by their relationship to the user’s eyes, field of view, illumination, resolution, color, stereopsis, effect on head motion and user interface. These optical and human factors considerations are important when selecting head-mounted displays for specific applications and patient groups. Conclusions Head-mounted display technologies may offer advantages over conventional low vision aids. Future research should compare head-mounted displays to commonly prescribed low vision aids in order to compare their effectiveness in addressing the impairments and rehabilitation goals of diverse patient populations. PMID:28048975

  1. Postural steadiness and ankle force variability in peripheral neuropathy

    Science.gov (United States)

    Paxton, Roger J.; Feldman-Kothe, Caitlin; Trabert, Megan K.; Hitchcock, Leah N.; Reiser, Raoul F.; Tracy, Brian L.

    2015-01-01

    Introduction The purpose was to determine the effect of peripheral neuropathy (PN) on motor output variability for ankle muscles of older adults, and the relation between ankle motor variability and postural stability in PN patients. Methods Older adults with (O-PN) and without PN (O), and young adults (Y) underwent assessment of standing postural stability and ankle muscle force steadiness. Results O-PN displayed impaired ankle muscle force control and postural stability compared with O and Y groups. For O-PN, the amplitude of plantarflexor force fluctuations was moderately correlated with postural stability under no-vision conditions (r = 0.54, P = 0.01). Discussion The correlation of variations in ankle force with postural stability in PN suggests a contribution of ankle muscle dyscontrol to the postural instability that impacts physical function for older adults with PN. PMID:26284897

  2. Learning from vision-to-touch is different than from touch-to-vision.

    Directory of Open Access Journals (Sweden)

    Dagmar A Wismeijer

    2012-11-01

    Full Text Available We studied whether vision can teach touch to the same extent as touch seems to teach vision. In a 2 x 2 between-participants learning study, we artificially correlated visual gloss cues with haptic compliance cues. In two "natural" tasks, we tested whether visual gloss estimations have an influence on haptic estimations of softness and vice versa. In two "new" tasks, in which participants were either asked to haptically judge glossiness or to visually judge softness, we investigated how perceptual estimates transfer from one sense to the other. Our results showed that vision does not teach touch as efficient as touch seems to teach vision.

  3. Value Creation and Supplier’s Capability Development in Relational Mechanism: The Case of Bangladeshi Apparel Industry

    DEFF Research Database (Denmark)

    Rana, Mohammad Bakhtiar; Imranul, Hoque

    2017-01-01

    the contrasting nature of governance, length of relationship, value of purchase and organizational vision of the two lead firms, our study investigates different sizes of suppliers and their value creation mechanism as well as capability development. Based on a focus group interview with 6 senior merchandisers...

  4. Peripheral biomarkers revisited: integrative profiling of peripheral samples for psychiatric research.

    Science.gov (United States)

    Hayashi-Takagi, Akiko; Vawter, Marquis P; Iwamoto, Kazuya

    2014-06-15

    Peripheral samples, such as blood and skin, have been used for decades in psychiatric research as surrogates for central nervous system samples. Although the validity of the data obtained from peripheral samples has been questioned and other state-of-the-art techniques, such as human brain imaging, genomics, and induced pluripotent stem cells, seem to reduce the value of peripheral cells, accumulating evidence has suggested that revisiting peripheral samples is worthwhile. Here, we re-evaluate the utility of peripheral samples and argue that establishing an understanding of the common signaling and biological processes in the brain and peripheral samples is required for the validity of such models. First, we present an overview of the available types of peripheral cells and describe their advantages and disadvantages. We then briefly summarize the main achievements of omics studies, including epigenome, transcriptome, proteome, and metabolome analyses, as well as the main findings of functional cellular assays, the results of which imply that alterations in neurotransmission, metabolism, the cell cycle, and the immune system may be partially responsible for the pathophysiology of major psychiatric disorders such as schizophrenia. Finally, we discuss the future utility of peripheral samples for the development of biomarkers and tailor-made therapies, such as multimodal assays that are used as a battery of disease and trait pathways and that might be potent and complimentary tools for use in psychiatric research. © 2013 Society of Biological Psychiatry Published by Society of Biological Psychiatry All rights reserved.

  5. Low Vision Rehabilitation and Diabetic Retinopathy

    International Nuclear Information System (INIS)

    Khan, Sarfaraz A.

    2007-01-01

    Diabetic retinopathy is emerging as a major cause of blindness. Diabetic retinopathy calls for a multidisciplinary to the patients. Management of the patient requires a team work by the internist, diabetologist, dietician, ophthalmologist and low vision therapist. Diabetic retinopathy very often results in vision loss. It is important for ophthalmologist to recognize the importance of low vision rehabilitation in formulating appropriate treatment strategies. People with low vision loss due to diabetic retinopathy usually experience difficulty in daily life. Most people with diabetic retinopathy (who have remaining useful vision) can be helped with low vision devices. However, often one low vision device may not be suitable for all purposes. A comprehensive low vision evaluation is required to assess the person's current visual status, identify the goals and the visual needs, and then design an individualized vision rehabilitation program to meet these needs. (author)

  6. Technology Assessment in Support of the Presidential Vision for Space Exploration

    Science.gov (United States)

    Weisbin, Charles R.; Lincoln, William; Mrozinski, Joe; Hua, Hook; Merida, Sofia; Shelton, Kacie; Adumitroaie, Virgil; Derleth, Jason; Silberg, Robert

    2006-01-01

    This paper discusses the process and results of technology assessment in support of the United States Vision for Space Exploration of the Moon, Mars and Beyond. The paper begins by reviewing the Presidential Vision: a major endeavor in building systems of systems. It discusses why we wish to return to the Moon, and the exploration architecture for getting there safely, sustaining a presence, and safely returning. Next, a methodology for optimal technology investment is proposed with discussion of inputs including a capability hierarchy, mission importance weightings, available resource profiles as a function of time, likelihoods of development success, and an objective function. A temporal optimization formulation is offered, and the investment recommendations presented along with sensitivity analyses. Key questions addressed are sensitivity of budget allocations to cost uncertainties, reduction in available budget levels, and shifting funding within constraints imposed by mission timeline.

  7. Robot Control for Dynamic Environment Using Vision and Autocalibration

    DEFF Research Database (Denmark)

    Larsen, Thomas Dall; Lildballe, Jacob; Andersen, Nils Axel

    1997-01-01

    To enhance flexibility and extend the area of applications for robotic systems, it is important that the systems are capable ofhandling uncertainties and respond to (random) human behaviour.A vision systemmust very often be able to work in a dynamical ``noisy'' world where theplacement ofobjects...... can vary within certain restrictions. Furthermore it would be useful ifthe system is able to recover automatically after serious changes have beenapplied, for instance if the camera has been moved.In this paper an implementationof such a system is described. The system is a robotcapable of playing...

  8. Fiber optic coherent laser radar 3d vision system

    International Nuclear Information System (INIS)

    Sebastian, R.L.; Clark, R.B.; Simonson, D.L.

    1994-01-01

    Recent advances in fiber optic component technology and digital processing components have enabled the development of a new 3D vision system based upon a fiber optic FMCW coherent laser radar. The approach includes a compact scanner with no moving parts capable of randomly addressing all pixels. The system maintains the immunity to lighting and surface shading conditions which is characteristic of coherent laser radar. The random pixel addressability allows concentration of scanning and processing on the active areas of a scene, as is done by the human eye-brain system

  9. Visual acuity and contrast sensitivity are two important factors affecting vision-related quality of life in advanced age-related macular degeneration.

    Science.gov (United States)

    Roh, Miin; Selivanova, Alexandra; Shin, Hyun Joon; Miller, Joan W; Jackson, Mary Lou

    2018-01-01

    Vision loss from age-related macular degeneration (AMD) has a profound effect on vision-related quality of life (VRQoL). The pupose of this study is to identify clinical factors associated with VRQoL using the Rasch- calibrated NEI VFQ-25 scales in bilateral advanced AMD patients. We retrospectively reviewed 47 patients (mean age 83.2 years) with bilateral advanced AMD. Clinical assessment included age, gender, type of AMD, high contrast visual acuity (VA), history of medical conditions, contrast sensitivity (CS), central visual field loss, report of Charles Bonnet Syndrome, current treatment for AMD and Rasch-calibrated NEI VFQ-25 visual function and socioemotional function scales. The NEI VFQ visual function scale includes items of general vision, peripheral vision, distance vision and near vision-related activity while the socioemotional function scale includes items of vision related-social functioning, role difficulties, dependency, and mental health. Multiple regression analysis (structural regression model) was performed using fixed item parameters obtained from the one-parameter item response theory model. Multivariate analysis showed that high contrast VA and CS were two factors influencing VRQoL visual function scale (β = -0.25, 95% CI-0.37 to -0.12, p<0.001 and β = 0.35, 95% CI 0.25 to 0.46, p<0.001) and socioemontional functioning scale (β = -0.2, 95% CI -0.37 to -0.03, p = 0.023, and β = 0.3, 95% CI 0.18 to 0.43, p = 0.001). Central visual field loss was not assoicated with either VRQoL visual or socioemontional functioning scale (β = -0.08, 95% CI-0.28 to 0.12,p = 0.44 and β = -0.09, 95% CI -0.03 to 0.16, p = 0.50, respectively). In patients with vision impairment secondary to bilateral advanced AMD, high contrast VA and CS are two important factors affecting VRQoL.

  10. Photoreceptor cells with profound structural deficits can support useful vision in mice.

    Science.gov (United States)

    Thompson, Stewart; Blodi, Frederick R; Lee, Swan; Welder, Chris R; Mullins, Robert F; Tucker, Budd A; Stasheff, Steven F; Stone, Edwin M

    2014-03-25

    In animal models of degenerative photoreceptor disease, there has been some success in restoring photoreception by transplanting stem cell-derived photoreceptor cells into the subretinal space. However, only a small proportion of transplanted cells develop extended outer segments, considered critical for photoreceptor cell function. The purpose of this study was to determine whether photoreceptor cells that lack a fully formed outer segment could usefully contribute to vision. Retinal and visual function was tested in wild-type and Rds mice at 90 days of age (Rds(P90)). Photoreceptor cells of mice homozygous for the Rds mutation in peripherin 2 never develop a fully formed outer segment. The electroretinogram and multielectrode recording of retinal ganglion cells were used to test retinal responses to light. Three distinct visual behaviors were used to assess visual capabilities: the optokinetic tracking response, the discrimination-based visual water task, and a measure of the effect of vision on wheel running. Rds(P90) mice had reduced but measurable electroretinogram responses to light, and exhibited light-evoked responses in multiple types of retinal ganglion cells, the output neurons of the retina. In optokinetic and discrimination-based tests, acuity was measurable but reduced, most notably when contrast was decreased. The wheel running test showed that Rds(P90) mice needed 3 log units brighter luminance than wild type to support useful vision (10 cd/m(2)). Photoreceptors that lack fully formed outer segments can support useful vision. This challenges the idea that normal cellular structure needs to be completely reproduced for transplanted cells to contribute to useful vision.

  11. Efficacy of vision therapy in children with learning disability and associated binocular vision anomalies.

    Science.gov (United States)

    Hussaindeen, Jameel Rizwana; Shah, Prerana; Ramani, Krishna Kumar; Ramanujan, Lalitha

    To report the frequency of binocular vision (BV) anomalies in children with specific learning disorders (SLD) and to assess the efficacy of vision therapy (VT) in children with a non-strabismic binocular vision anomaly (NSBVA). The study was carried out at a centre for learning disability (LD). Comprehensive eye examination and binocular vision assessment was carried out for 94 children (mean (SD) age: 15 (2.2) years) diagnosed with specific learning disorder. BV assessment was done for children with best corrected visual acuity of ≥6/9 - N6, cooperative for examination and free from any ocular pathology. For children with a diagnosis of NSBVA (n=46), 24 children were randomized to VT and no intervention was provided to the other 22 children who served as experimental controls. At the end of 10 sessions of vision therapy, BV assessment was performed for both the intervention and non-intervention groups. Binocular vision anomalies were found in 59 children (62.8%) among which 22% (n=13) had strabismic binocular vision anomalies (SBVA) and 78% (n=46) had a NSBVA. Accommodative infacility (AIF) was the commonest of the NSBVA and found in 67%, followed by convergence insufficiency (CI) in 25%. Post-vision therapy, the intervention group showed significant improvement in all the BV parameters (Wilcoxon signed rank test, p<0.05) except negative fusional vergence. Children with specific learning disorders have a high frequency of binocular vision disorders and vision therapy plays a significant role in improving the BV parameters. Children with SLD should be screened for BV anomalies as it could potentially be an added hindrance to the reading difficulty in this special population. Copyright © 2017 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.

  12. Management of peripheral polypoidal choroidal vasculopathy with intravitreal bevacizumab and indocyanine green angiography-guided laser photocoagulation

    Directory of Open Access Journals (Sweden)

    Pukhraj Rishi

    2012-01-01

    Full Text Available A 69-year-old lady presented with complaints of decreased vision in left eye since one month. Best Corrected Visual Acuity (BCVA was 6/18 in that eye. Fundus examination revealed non-central geographic atrophy and soft drusens at macula in both eyes. Temporal periphery of left eye revealed subretinal exudates with altered sub-RPE hemorrhage mimicking peripheral exudative hemorrhagic chorioretinopathy (PEHCR. Fundus Fluorescein Angiogram showed window defects at macula and blocked fluorescence at temporal periphery in left eye. However, Indocyanine green angiography (ICGA revealed active peripheral choroidal polyps. The patient was successfully treated with intravitreal bevacizumab and ICGA-guided laser photocoagulation. 27 months after laser treatment, BCVA improved to 6/9. Rationale of consecutive anti-vascular endothelial growth factor (VEGF treatment followed by more definitive laser photocoagulation is that anti-VEGF aids in resolution of subretinal fluid, thus making the polyp more amenable to focal laser photocoagulation which stabilizes the choroidal vasculature and prevents further leakage.

  13. Synthetic vision to augment sensor based vision for remotely piloted vehicles

    NARCIS (Netherlands)

    Tadema, J.; Koeners, J.; Theunissen, E.

    2006-01-01

    In the past fifteen years, several research programs have demonstrated potential advantages of synthetic vision technology for manned aviation. More recently, some research programs have focused on integrating synthetic vision technology into control stations for remotely controlled aircraft. The

  14. Unstructured Grid Adaptation: Status, Potential Impacts, and Recommended Investments Toward CFD Vision 2030

    Science.gov (United States)

    Park, Michael A.; Krakos, Joshua A.; Michal, Todd; Loseille, Adrien; Alonso, Juan J.

    2016-01-01

    Unstructured grid adaptation is a powerful tool to control discretization error for Computational Fluid Dynamics (CFD). It has enabled key increases in the accuracy, automation, and capacity of some fluid simulation applications. Slotnick et al. provides a number of case studies in the CFD Vision 2030 Study: A Path to Revolutionary Computational Aerosciences to illustrate the current state of CFD capability and capacity. The authors forecast the potential impact of emerging High Performance Computing (HPC) environments forecast in the year 2030 and identify that mesh generation and adaptivity continue to be significant bottlenecks in the CFD work flow. These bottlenecks may persist because very little government investment has been targeted in these areas. To motivate investment, the impacts of improved grid adaptation technologies are identified. The CFD Vision 2030 Study roadmap and anticipated capabilities in complementary disciplines are quoted to provide context for the progress made in grid adaptation in the past fifteen years, current status, and a forecast for the next fifteen years with recommended investments. These investments are specific to mesh adaptation and impact other aspects of the CFD process. Finally, a strategy is identified to diffuse grid adaptation technology into production CFD work flows.

  15. Vision based condition assessment of structures

    International Nuclear Information System (INIS)

    Uhl, Tadeusz; Kohut, Piotr; Holak, Krzysztof; Krupinski, Krzysztof

    2011-01-01

    In this paper, a vision-based method for measuring a civil engineering construction's in-plane deflection curves is presented. The displacement field of the analyzed object which results from loads was computed by means of a digital image correlation coefficient. Image registration techniques were introduced to increase the flexibility of the method. The application of homography mapping enabled the deflection field to be computed from two images of the structure, acquired from two different points in space. An automatic shape filter and a corner detector were implemented to calculate the homography mapping between the two views. The developed methodology, created architecture and the capabilities of software tools, as well as experimental results obtained from tests made on a lab set-up and civil engineering constructions, are discussed.

  16. What You Should Know (Low Vision)

    Science.gov (United States)

    ... Cataract Diabetic retinopathy Glaucoma Macular degeneration What is low vision? When you have low vision, eyeglasses, contact lenses, ... eyesight. How do I know if I have low vision? Below are some signs of low vision. Even ...

  17. Peripheral reactions

    International Nuclear Information System (INIS)

    Greiner, D.

    1978-01-01

    Peripheral collisions, that is, collisions involving a small amount of overlap of nuclear matter, are discussed including inclusive interactions, the magnitude of the peripheral cross section, fragmentation, a compilation of experiments and available data, limiting fragmentation, factorization, some models, fragment momentum distributions, and future research directions

  18. Leadership capabilities of physiotherapy leaders in Ireland: Part 1 physiotherapy managers.

    Science.gov (United States)

    McGowan, Emer; Elliott, Naomi; Stokes, Emma

    2018-05-07

    Investigation of the leadership capabilities of physiotherapists is needed to allow understanding of current leadership practice and to enable appropriate training programs to be developed. To explore physiotherapy managers´ perceptions of their leadership capabilities. Semi-structured interviews were conducted with a purposive sample of 18 physiotherapy managers from a range of public services and private practices in Ireland. The interviews were analyzed using template analysis and the coding template was based on the Bolman and Deal Leadership framework which details four leadership frames: structural, human resource, political, and symbolic. The physiotherapy managers described demonstrating leadership capabilities associated with each of the four leadership frames. However, the language used by the physiotherapy managers suggested that they work predominantly through the structural and human resource frames. The employment of capabilities associated with the political frame varied between participants; some participants described working through this frame while others reported difficulties. The symbolic frame was underused; there were fewer examples given of capabilities such as communicating their vision, demonstrating passion and facilitating a positive workplace culture. Physiotherapy managers work predominantly through the structural and human resource frames. To successfully meet the leadership requirements of their roles physiotherapy managers may benefit from specific leadership development training to develop leadership capabilities in the political and symbolic frames.

  19. Gamma-Ray imaging for nuclear security and safety: Towards 3-D gamma-ray vision

    Science.gov (United States)

    Vetter, Kai; Barnowksi, Ross; Haefner, Andrew; Joshi, Tenzing H. Y.; Pavlovsky, Ryan; Quiter, Brian J.

    2018-01-01

    The development of portable gamma-ray imaging instruments in combination with the recent advances in sensor and related computer vision technologies enable unprecedented capabilities in the detection, localization, and mapping of radiological and nuclear materials in complex environments relevant for nuclear security and safety. Though multi-modal imaging has been established in medicine and biomedical imaging for some time, the potential of multi-modal data fusion for radiological localization and mapping problems in complex indoor and outdoor environments remains to be explored in detail. In contrast to the well-defined settings in medical or biological imaging associated with small field-of-view and well-constrained extension of the radiation field, in many radiological search and mapping scenarios, the radiation fields are not constrained and objects and sources are not necessarily known prior to the measurement. The ability to fuse radiological with contextual or scene data in three dimensions, in analog to radiological and functional imaging with anatomical fusion in medicine, provides new capabilities enhancing image clarity, context, quantitative estimates, and visualization of the data products. We have developed new means to register and fuse gamma-ray imaging with contextual data from portable or moving platforms. These developments enhance detection and mapping capabilities as well as provide unprecedented visualization of complex radiation fields, moving us one step closer to the realization of gamma-ray vision in three dimensions.

  20. Idaho National Laboratory Ten-year Site Plan (2012 through 2021) -- DOE-NE's National Nuclear Capability -- Developing and Maintaining the INL Infrastructure

    Energy Technology Data Exchange (ETDEWEB)

    Cal Ozaki

    2010-06-01

    To meet long-term objectives to transform the Idaho National Laboratory (INL), we are providing an integrated, long-term vision of infrastructure requirements that support research, development and demonstration (RD&D) goals outlined in the DOE strategic plans, including the NE Roadmap and reports such as Facilities for the Future of Nuclear Energy Research: A Twenty-year Outlook. The goal of the INL Ten-year Site Plan (TYSP) is to clearly link RD&D mission goals and INL core capabilities with infrastructure requirements (single and multi-program), establish the 10-year end-state vision for INL complexes, identify and prioritize infrastructure and capability gaps, as well as the most efficient and economic approaches to closing those gaps.

  1. Women and the vision thing.

    Science.gov (United States)

    Ibarra, Herminia; Obodaru, Otilia

    2009-01-01

    Are women rated lower than men in evaluations of their leadership capabilities because of lingering gender bias? No, according to an analysis of thousands of 360-degree assessments collected by Insead's executive education program. That analysis showed that women tend to outshine men in all areas but one: vision. Unfortunately, that exception is a big one. At the top tiers of management, the ability to see opportunities, craft strategy based on a broad view of the business, and inspire others is a must-have. To explore the nature of the deficit, and whether it is a perception or reality, Insead professor Ibarra and doctoral candidate Obodaru interviewed female executives and studied the evaluation data. They developed three possible explanations. First, women may do just as much as men to shape the future but go about it in a different way; a leader who is less directive, includes more people, and shares credit might not fit people's mental model of a visionary. Second, women may believe they have less license to go out on a limb. Those who have built careers on detail-focused, shoulder-to-the-wheel execution may hesitate to stray from facts into unprovable assertions about the future. Third, women may choose not to cultivate reputations as big visionaries. Having seen bluster passed off as vision, they may dismiss the importance of selling visions. The top two candidates for the Democratic nomination for U.S. president in 2008 offer an instructive parallel. The runner-up, Hillary Clinton, was viewed as a get-it-done type with an impressive, if uninspiring, grasp of policy detail. The winner, Barack Obama, was seen as a charismatic visionary offering a hopeful, if undetailed, future. The good news is that every dimension of leadership is learned, not inborn. As more women become skilled at, and known for, envisioning the future, nothing will hold them back.

  2. Vision Problems in Homeless Children.

    Science.gov (United States)

    Smith, Natalie L; Smith, Thomas J; DeSantis, Diana; Suhocki, Marissa; Fenske, Danielle

    2015-08-01

    Vision problems in homeless children can decrease educational achievement and quality of life. To estimate the prevalence and specific diagnoses of vision problems in children in an urban homeless shelter. A prospective series of 107 homeless children and teenagers who underwent screening with a vision questionnaire, eye chart screening (if mature enough) and if vision problem suspected, evaluation by a pediatric ophthalmologist. Glasses and other therapeutic interventions were provided if necessary. The prevalence of vision problems in this population was 25%. Common diagnoses included astigmatism, amblyopia, anisometropia, myopia, and hyperopia. Glasses were required and provided for 24 children (22%). Vision problems in homeless children are common and frequently correctable with ophthalmic intervention. Evaluation by pediatric ophthalmologist is crucial for accurate diagnoses and treatment. Our system of screening and evaluation is feasible, efficacious, and reproducible in other homeless care situations.

  3. Genetics Home Reference: color vision deficiency

    Science.gov (United States)

    ... my area? Other Names for This Condition color blindness color vision defects defective color vision vision defect, color ... Perception KidsHealth from the Nemours Foundation MalaCards: color blindness MalaCards: color vision deficiency Orphanet: Blue cone monochromatism Orphanet: NON ...

  4. Episodic Reasoning for Vision-Based Human Action Recognition

    Directory of Open Access Journals (Sweden)

    Maria J. Santofimia

    2014-01-01

    Full Text Available Smart Spaces, Ambient Intelligence, and Ambient Assisted Living are environmental paradigms that strongly depend on their capability to recognize human actions. While most solutions rest on sensor value interpretations and video analysis applications, few have realized the importance of incorporating common-sense capabilities to support the recognition process. Unfortunately, human action recognition cannot be successfully accomplished by only analyzing body postures. On the contrary, this task should be supported by profound knowledge of human agency nature and its tight connection to the reasons and motivations that explain it. The combination of this knowledge and the knowledge about how the world works is essential for recognizing and understanding human actions without committing common-senseless mistakes. This work demonstrates the impact that episodic reasoning has in improving the accuracy of a computer vision system for human action recognition. This work also presents formalization, implementation, and evaluation details of the knowledge model that supports the episodic reasoning.

  5. Learning from vision-to-touch is different than learning from touch-to-vision.

    Science.gov (United States)

    Wismeijer, Dagmar A; Gegenfurtner, Karl R; Drewing, Knut

    2012-01-01

    We studied whether vision can teach touch to the same extent as touch seems to teach vision. In a 2 × 2 between-participants learning study, we artificially correlated visual gloss cues with haptic compliance cues. In two "natural" tasks, we tested whether visual gloss estimations have an influence on haptic estimations of softness and vice versa. In two "novel" tasks, in which participants were either asked to haptically judge glossiness or to visually judge softness, we investigated how perceptual estimates transfer from one sense to the other. Our results showed that vision does not teach touch as efficient as touch seems to teach vision.

  6. IDA's Energy Vision 2050

    DEFF Research Database (Denmark)

    Mathiesen, Brian Vad; Lund, Henrik; Hansen, Kenneth

    IDA’s Energy Vision 2050 provides a Smart Energy System strategy for a 100% renewable Denmark in 2050. The vision presented should not be regarded as the only option in 2050 but as one scenario out of several possibilities. With this vision the Danish Society of Engineers, IDA, presents its third...... contribution for an energy strategy for Denmark. The IDA’s Energy Plan 2030 was prepared in 2006 and IDA’s Climate Plan was prepared in 2009. IDA’s Energy Vision 2050 is developed for IDA by representatives from The Society of Engineers and by a group of researchers at Aalborg University. It is based on state......-of-the-art knowledge about how low cost energy systems can be designed while also focusing on long-term resource efficiency. The Energy Vision 2050 has the ambition to focus on all parts of the energy system rather than single technologies, but to have an approach in which all sectors are integrated. While Denmark...

  7. FPGA Vision Data Architecture

    Science.gov (United States)

    Morfopoulos, Arin C.; Pham, Thang D.

    2013-01-01

    JPL has produced a series of FPGA (field programmable gate array) vision algorithms that were written with custom interfaces to get data in and out of each vision module. Each module has unique requirements on the data interface, and further vision modules are continually being developed, each with their own custom interfaces. Each memory module had also been designed for direct access to memory or to another memory module.

  8. FLORA™: Phase I development of a functional vision assessment for prosthetic vision users.

    Science.gov (United States)

    Geruschat, Duane R; Flax, Marshall; Tanna, Nilima; Bianchi, Michelle; Fisher, Andy; Goldschmidt, Mira; Fisher, Lynne; Dagnelie, Gislin; Deremeik, Jim; Smith, Audrey; Anaflous, Fatima; Dorn, Jessy

    2015-07-01

    Research groups and funding agencies need a functional assessment suitable for an ultra-low vision population to evaluate the impact of new vision-restoration treatments. The purpose of this study was to develop a pilot assessment to capture the functional visual ability and well-being of subjects whose vision has been partially restored with the Argus II Retinal Prosthesis System. The Functional Low-Vision Observer Rated Assessment (FLORA) pilot assessment involved a self-report section, a list of functional visual tasks for observation of performance and a case narrative summary. Results were analysed to determine whether the interview questions and functional visual tasks were appropriate for this ultra-low vision population and whether the ratings suffered from floor or ceiling effects. Thirty subjects with severe to profound retinitis pigmentosa (bare light perception or worse in both eyes) were enrolled in a clinical trial and implanted with the Argus II System. From this population, 26 subjects were assessed with the FLORA. Seven different evaluators administered the assessment. All 14 interview questions were asked. All 35 tasks for functional vision were selected for evaluation at least once, with an average of 20 subjects being evaluated for each test item. All four rating options—impossible (33 per cent), difficult (23 per cent), moderate (24 per cent) and easy (19 per cent)—were used by the evaluators. Evaluators also judged the amount of vision they observed the subjects using to complete the various tasks, with 'vision only' occurring 75 per cent on average with the System ON, and 29 per cent with the System OFF. The first version of the FLORA was found to contain useful elements for evaluation and to avoid floor and ceiling effects. The next phase of development will be to refine the assessment and to establish reliability and validity to increase its value as an assessment tool for functional vision and well-being. © 2015 The Authors. Clinical

  9. Peripheral Developing Odontoma or Peripheral Ameloblastic Fibroodontoma: A Rare Challenging Case

    Directory of Open Access Journals (Sweden)

    Saede Atarbashi Moghadam

    2016-01-01

    Full Text Available Peripheral odontogenic lesions are considered to be rare within the classification of odontogenic tumors. They share the same microscopic characteristics of their central counterparts. Here, we report an ulcerated mass of the maxillary gingiva that on histopathological examination was diagnosed as peripheral developing odontoma or peripheral ameloblastic fibroodontoma. The diagnosis of this tumor is challenging and may lead to unnecessary treatment.

  10. Modeling foveal vision

    NARCIS (Netherlands)

    Florack, L.M.J.; Sgallari, F.; Murli, A.; Paragios, N.

    2007-01-01

    geometric model is proposed for an artificial foveal vision system, and its plausibility in the context of biological vision is explored. The model is based on an isotropic, scale invariant two-form that describes the spatial layout of receptive fields in the the visual sensorium (in the biological

  11. Peripheral Neuropathy and Agent Orange

    Science.gov (United States)

    ... Enter ZIP code here Enter ZIP code here Peripheral Neuropathy and Agent Orange VA presumes Veterans' early-onset ... 10 percent disabling by VA's rating regulations. About peripheral neuropathy Peripheral neuropathy is a condition of the peripheral ...

  12. The AMTEX Partnership{trademark}: Creating and implementing a vision

    Energy Technology Data Exchange (ETDEWEB)

    Liebetrau, S.F.; Erickson, M.D.; Lemon, D.K.

    1993-12-01

    The vision and creativity of the multilaboratory team nominated for a special award resulted in the AMTEX Partnership{trademark}, a pace-setting agreement between US Department of Energy national laboratories and the US textile industry. The AMTEX Partnership is a role model for America to follow that brings the resources of government to bear on industrial needs while preserving the American values of free enterprise and fairness of opportunity. Together, the nominees created an important vision of the future. They capitalized on a government-sponsored workshop that provided an opportunity for industry to hear about laboratory capabilities. At the workshop, they attracted the attention of the integrated textile industry, a major segment of US industry whose economic future is very much at risk. They listened to the industry representatives, grasped the scope and implications of the industry`s needs - and recognized the potential for large-scale collaboration. In keeping with the scale of this prospect, they guided nine national laboratories from traditional ways of technology transfer into a cooperative venture with an entire vertically integrated industry.

  13. Impact of low vision services on the quality of life of low vision patients in Ghana

    Directory of Open Access Journals (Sweden)

    Godwin O. Ovenseri-Ogbomo

    2016-03-01

    Full Text Available Patients’ perspectives on the impact of clinical interventions have been recognised as critical elements in patient care. Quality-of-life instruments are designed to measure these perspectives. We used the National Eye Institute’s 25-item Visual Function Questionnaire (NEI VFQ to measure the impact of optical low vision devices on the quality of life of 22 low vision patients who obtained and were using low vision devices from a secondary low vision clinic in the Eastern Region, Ghana. The study employed a pre- and post-intervention technique. We found statistically significant improvements in measured visual acuity and NEI VFQ scores in 8 of the 10 domains evaluated. We conclude that optical low vision devices have a positive impact on the quality of life of low vision patients in Ghana. Keywords: low vision; quality of life; visual acuity; visual impairment; Ghana

  14. Vascular access in neonatology: peripherally inserted central catheter and peripheral venous catheter

    Directory of Open Access Journals (Sweden)

    Marcia Lienemann

    2014-04-01

    The objective of this paper is to present aspects of peripherally inserted central catheter and peripheral venous catheter, highlighting important points in choosing the type of access. For the passage of peripherally inserted central catheter is previously performing specific course necessary, while the primary indication occurs when it is necessary to access the patient's stay for a long period of time. Whereas peripheral venipuncture is the most appropriate in cases of needing an IV line quickly and safely, for the administration of fluids, blood collection, blood transfusion and other.

  15. Industrial vision

    DEFF Research Database (Denmark)

    Knudsen, Ole

    1998-01-01

    This dissertation is concerned with the introduction of vision-based application s in the ship building industry. The industrial research project is divided into a natural seq uence of developments, from basic theoretical projective image generation via CAD and subpixel analysis to a description...... is present ed, and the variability of the parameters is examined and described. The concept of using CAD together with vision information is based on the fact that all items processed at OSS have an associated complete 3D CAD model that is accessible at all production states. This concept gives numerous...... possibilities for using vision in applications which otherwise would be very difficult to automate. The requirement for low tolerances in production is, despite the huge dimensions of the items involved, extreme. This fact makes great demands on the ability to do robust sub pixel estimation. A new method based...

  16. Company Vision and Organizational Learning

    Directory of Open Access Journals (Sweden)

    Vojko Toman

    2015-11-01

    Full Text Available The effectiveness of a company is largely dependent on the company itself; it depends above all on its corporate governance, management, and implementation, as well as on decision-making processes and coordination. Many authors believe that organizational learning and knowledge are the most relevant aspects of company effectiveness. If a company wants to be effective it needs to create and realize its vision; to do this, it needs creativity, imagination, and knowledge, which can be obtained or enhanced through learning. This paper defines vision, learning, creativity and management and, above all, their relationships. The author argues that company vision influences the learning and knowledge of employees in the company through the vision’s content, through the vision-creating process, and through the vision enforcement process. Conversely, the influence of learning on company vision is explained. The paper is aimed at the use in the practice of companies and helps them to increase their effectiveness.

  17. Visual Search Performance in Patients with Vision Impairment: A Systematic Review.

    Science.gov (United States)

    Senger, Cassia; Margarido, Maria Rita Rodrigues Alves; De Moraes, Carlos Gustavo; De Fendi, Ligia Issa; Messias, André; Paula, Jayter Silva

    2017-11-01

    Patients with visual impairment are constantly facing challenges to achieve an independent and productive life, which depends upon both a good visual discrimination and search capacities. Given that visual search is a critical skill for several daily tasks and could be used as an index of the overall visual function, we investigated the relationship between vision impairment and visual search performance. A comprehensive search was undertaken using electronic PubMed, EMBASE, LILACS, and Cochrane databases from January 1980 to December 2016, applying the following terms: "visual search", "visual search performance", "visual impairment", "visual exploration", "visual field", "hemianopia", "search time", "vision lost", "visual loss", and "low vision". Two hundred seventy six studies from 12,059 electronic database files were selected, and 40 of them were included in this review. Studies included participants of all ages, both sexes, and the sample sizes ranged from 5 to 199 participants. Visual impairment was associated with worse visual search performance in several ophthalmologic conditions, which were either artificially induced, or related to specific eye and neurological diseases. This systematic review details all the described circumstances interfering with visual search tasks, highlights the need for developing technical standards, and outlines patterns for diagnosis and therapy using visual search capabilities.

  18. Development of a Wireless Computer Vision Instrument to Detect Biotic Stress in Wheat

    Directory of Open Access Journals (Sweden)

    Joaquin J. Casanova

    2014-09-01

    Full Text Available Knowledge of crop abiotic and biotic stress is important for optimal irrigation management. While spectral reflectance and infrared thermometry provide a means to quantify crop stress remotely, these measurements can be cumbersome. Computer vision offers an inexpensive way to remotely detect crop stress independent of vegetation cover. This paper presents a technique using computer vision to detect disease stress in wheat. Digital images of differentially stressed wheat were segmented into soil and vegetation pixels using expectation maximization (EM. In the first season, the algorithm to segment vegetation from soil and distinguish between healthy and stressed wheat was developed and tested using digital images taken in the field and later processed on a desktop computer. In the second season, a wireless camera with near real-time computer vision capabilities was tested in conjunction with the conventional camera and desktop computer. For wheat irrigated at different levels and inoculated with wheat streak mosaic virus (WSMV, vegetation hue determined by the EM algorithm showed significant effects from irrigation level and infection. Unstressed wheat had a higher hue (118.32 than stressed wheat (111.34. In the second season, the hue and cover measured by the wireless computer vision sensor showed significant effects from infection (p = 0.0014, as did the conventional camera (p < 0.0001. Vegetation hue obtained through a wireless computer vision system in this study is a viable option for determining biotic crop stress in irrigation scheduling. Such a low-cost system could be suitable for use in the field in automated irrigation scheduling applications.

  19. Understanding and preventing computer vision syndrome.

    Science.gov (United States)

    Loh, Ky; Redd, Sc

    2008-01-01

    The invention of computer and advancement in information technology has revolutionized and benefited the society but at the same time has caused symptoms related to its usage such as ocular sprain, irritation, redness, dryness, blurred vision and double vision. This cluster of symptoms is known as computer vision syndrome which is characterized by the visual symptoms which result from interaction with computer display or its environment. Three major mechanisms that lead to computer vision syndrome are extraocular mechanism, accommodative mechanism and ocular surface mechanism. The visual effects of the computer such as brightness, resolution, glare and quality all are known factors that contribute to computer vision syndrome. Prevention is the most important strategy in managing computer vision syndrome. Modification in the ergonomics of the working environment, patient education and proper eye care are crucial in managing computer vision syndrome.

  20. UNDERSTANDING AND PREVENTING COMPUTER VISION SYNDROME

    Directory of Open Access Journals (Sweden)

    REDDY SC

    2008-01-01

    Full Text Available The invention of computer and advancement in information technology has revolutionized and benefited the society but at the same time has caused symptoms related to its usage such as ocular sprain, irritation, redness, dryness, blurred vision and double vision. This cluster of symptoms is known as computer vision syndrome which is characterized by the visual symptoms which result from interaction with computer display or its environment. Three major mechanisms that lead to computer vision syndrome are extraocular mechanism, accommodative mechanism and ocular surface mechanism. The visual effects of the computer such as brightness, resolution, glare and quality all are known factors that contribute to computer vision syndrome. Prevention is the most important strategy in managing computer vision syndrome. Modification in the ergonomics of the working environment, patient education and proper eye care are crucial in managing computer vision syndrome.

  1. Virtual bronchoscopy-guided transbronchial biopsy for aiding the diagnosis of peripheral lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Iwano, Shingo, E-mail: iwano45@med.nagoya-u.ac.jp [Department of Radiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Shouwa-ku, Nagoya 4668550, Aichi (Japan); Imaizumi, Kazuyoshi [Department of Respiratory Medicine, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Shouwa-ku, Nagoya 4668550 (Japan); Okada, Tohru [Research Center for Charged Particle Therapy, National Institute of Radiological Science, 4-9-1 Anagawa, Inage-ku, Chiba 2638555 (Japan); Hasegawa, Yoshinori [Department of Respiratory Medicine, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Shouwa-ku, Nagoya 4668550 (Japan); Naganawa, Shinji [Department of Radiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Shouwa-ku, Nagoya 4668550, Aichi (Japan)

    2011-07-15

    Objective: The aim of this study was to evaluate the clinical value of virtual bronchoscopy (VB) in aiding diagnosis of peripheral lung cancer by transbronchial biopsy (TBB). In addition, we sought to systematically analyze the factors that affect the diagnostic sensitivity of VB-guided TBB for the evaluation of peripheral lung cancers. Materials and methods: A hundred and twenty-two peripheral lung cancers from 122 patients (82 men and 40 women, 38-84 years; median 68.5 years) who were performed VB-guided TBB were evaluated retrospectively. VB was reconstructed from 1- or 0.5-mm slice thickness images of multi-detector CT (MDCT). Experienced pulmonologists inserted the conventional and ultrathin bronchoscopes into the target bronchus under direct vision following the VB image. Results: A definitive diagnosis was established by VB-guided TBB in 96 lesions (79%). The diagnostic sensitivity of small pulmonary lesions {<=}30 mm in maximal diameter (71%) was significantly lower than that of lesions >30 mm (91%, p = 0.008). For small pulmonary lesions {<=}30 mm (n = 76), internal opacity of the lesion was the independent predictor of diagnostic sensitivity by VB-guided TBB, and the non-solid type lung cancers were significantly lower than the solid type and part-solid type lung cancers for diagnostic sensitivity (odds ratio = 0.161; 95% confidence interval = 0.033-0.780; p = 0.023). Conclusion: Use of an ultrathin bronchoscope and simulation with VB reconstructed by high quality MDCT images is thought to improve pathological diagnosis of peripheral lung cancers, especially for solid and partly solid types. For small pulmonary lesions {<=}30 mm, the lesion internal opacity is a significant factor for predicting the diagnostic sensitivity, and the sensitivity was low for small non-solid type of lung cancers.

  2. [Quality system Vision 2000].

    Science.gov (United States)

    Pasini, Evasio; Pitocchi, Oreste; de Luca, Italo; Ferrari, Roberto

    2002-12-01

    A recent document of the Italian Ministry of Health points out that all structures which provide services to the National Health System should implement a Quality System according to the ISO 9000 standards. Vision 2000 is the new version of the ISO standard. Vision 2000 is less bureaucratic than the old version. The specific requests of the Vision 2000 are: a) to identify, to monitor and to analyze the processes of the structure, b) to measure the results of the processes so as to ensure that they are effective, d) to implement actions necessary to achieve the planned results and the continual improvement of these processes, e) to identify customer requests and to measure customer satisfaction. Specific attention should be also dedicated to the competence and training of the personnel involved in the processes. The principles of the Vision 2000 agree with the principles of total quality management. The present article illustrates the Vision 2000 standard and provides practical examples of the implementation of this standard in cardiological departments.

  3. Predictors of vision impairment in Multiple Sclerosis.

    Science.gov (United States)

    Sanchez-Dalmau, Bernardo; Martinez-Lapiscina, Elena H; Pulido-Valdeolivas, Irene; Zubizarreta, Irati; Llufriu, Sara; Blanco, Yolanda; Sola-Valls, Nuria; Sepulveda, Maria; Guerrero, Ana; Alba, Salut; Andorra, Magi; Camos, Anna; Sanchez-Vela, Laura; Alfonso, Veronica; Saiz, Albert; Villoslada, Pablo

    2018-01-01

    Visual impairment significantly alters the quality of life of people with Multiple Sclerosis (MS). The objective of this study was to identify predictors (independent variables) of visual outcomes, and to define their relationship with neurological disability and retinal atrophy when assessed by optical coherence tomography (OCT). We performed a cross-sectional analysis of 119 consecutive patients with MS, assessing vision using high contrast visual acuity (LogMar), 2.5% and 1.25% low contrast visual acuity (Sloan charts), and color vision (Hardy-Rand-Rittler plates). Quality of vision is a patient reported outcome based on an individual's unique perception of his or her vision and was assessed with the Visual Functioning Questionnaire-25 (VFQ-25) with the 10 neuro-ophthalmologic items. MS disability was assessed using the expanded disability status scale (EDSS), the MS functional composite (MSFC) and the brief repetitive battery-neuropsychology (BRB-N). Retinal atrophy was assessed using spectral domain OCT, measuring the thickness of the peripapillar retinal nerve fiber layer (pRNFL) and the volume of the ganglion cell plus inner plexiform layer (GCIPL). The vision of patients with MS was impaired, particularly in eyes with prior optic neuritis. Retinal atrophy (pRNFL and GCIPL) was closely associated with impaired low contrast vision and color vision, whereas the volume of the GCIPL showed a trend (p = 0.092) to be associated with quality of vision. Multiple regression analysis revealed that EDSS was an explanatory variable for high contrast vision after stepwise analysis, GCIPL volume for low contrast vision, and GCIPL volume and EDSS for color vision. The explanatory variables for quality of vision were high contrast vision and color vision. In summary, quality of vision in MS depends on the impairment of high contrast visual acuity and color vision due to the disease.

  4. Comparison of Views of Allame Tabatabai and M.Arabi on Vision and Seeing

    Directory of Open Access Journals (Sweden)

    Forugh Rahimpur

    2010-01-01

    Full Text Available This paper compares vision, in general, and seeing God, in particular from two view points: Allame M.H.Tabatabai’s and M.Arabi’s, who are representatives of two school of Hikmat Mutaalie and Gnosticism. Subjects such as: heart as the place of receiving vision, the factors for incerasing heart’s receiving capability of the inspirations, error in visionary knowledge, criteria for finding these errors and seeing God are investigated in this paper. A quick look at these two scholars’ definition of “vision” makes one think that these two views are complementary and point to the same direction.Also there are similarities in their approach to the subject of vision. For example, both agreed that the heart is the place to receive the vision and Aref can increase his heart’s receiving ability by some self-watching exercises. They both believe that it is possible for visionary knowledge to be erroneous for the probability of non-divine sources of revelations or inspirations and wrong interpretations of observations. However, there are important differences between the thinking methods of Allameh and Ibn Arabi, the most crucial of which is the different position of rational mind in their views.As for Allameh, unlike Ibn Arabi, it has a special importance as a cognitive tool and he refers to it as a criterion for the validity of visionary knowledge.

  5. Vision based condition assessment of structures

    Energy Technology Data Exchange (ETDEWEB)

    Uhl, Tadeusz; Kohut, Piotr; Holak, Krzysztof; Krupinski, Krzysztof, E-mail: tuhl@agh.edu.pl, E-mail: pko@agh.edu.pl, E-mail: holak@agh.edu.pl, E-mail: krzysiek.krupinski@wp.pl [Department of Robotics and Mechatronics, AGH-University of Science and Technology, Al.Mickiewicza 30, 30-059 Cracow (Poland)

    2011-07-19

    In this paper, a vision-based method for measuring a civil engineering construction's in-plane deflection curves is presented. The displacement field of the analyzed object which results from loads was computed by means of a digital image correlation coefficient. Image registration techniques were introduced to increase the flexibility of the method. The application of homography mapping enabled the deflection field to be computed from two images of the structure, acquired from two different points in space. An automatic shape filter and a corner detector were implemented to calculate the homography mapping between the two views. The developed methodology, created architecture and the capabilities of software tools, as well as experimental results obtained from tests made on a lab set-up and civil engineering constructions, are discussed.

  6. [Comparison of the Pressure on the Larynx and Tongue Using McGRATH® MAC Video Laryngoscope--Direct Vision versus Indirect Vision].

    Science.gov (United States)

    Tanaka, Yasutomo; Miyazaki, Yukiko; Kitakata, Hidenori; Shibuya, Hiromi; Okada, Toshiki

    2015-12-01

    Studies show that McGRATH® MAC (McG) is useful during direct laryngoscopy. However, no study has examined whether McG re- duces pressure on the upper airway tract We compared direct vision with indirect vision concerning pressure on the larynx and tongue. Twenty two anesthesiologists and 16 junior residents attempted direct laryngoscopy of airway management simulator using McG with direct vision and indirect vision. Pressure was measured using pressure measurement film. In anesthesiologists group, pressure on larynx was 14.8 ± 2.7 kgf · cm(-2) with direct vision and 12.7 ± 2.7 kgf · cm(-2) with indirect vision (P vision and 7.6 ± 2.8 kgf · cm(-2) with indirect vision (P = 0.18). In junior residents group, pressure on larynx was 19.0 ± 1.3 kgf · cm(-2) with direct vision and 14.1 ± 3.1 kgf · cm(-2) with indirect vision (P vision and 11.2 ± 4.7 kgf · cm(-2) with indirect vision (P vision can reduce pressure on the upper airway tract.

  7. A new measure for the assessment of visual awareness in individuals with tunnel vision.

    Science.gov (United States)

    AlSaqr, Ali M; Dickinson, Chris M

    2017-01-01

    Individuals with a restricted peripheral visual field or tunnel vision (TV) have problems moving about and avoiding obstacles. Some individuals adapt better than others and some use assistive optical aids, so measurement of the visual field is not sufficient to describe their performance. In the present study, we developed a new clinical test called the 'Assessment of Visual Awareness (AVA)', which can be used to measure detection of peripheral targets. The participants were 20 patients with TV due to retinitis pigmentosa (PTV) and 50 normally sighted participants with simulated tunnel vision (STV) using goggles. In the AVA test, detection times were measured, when subjects searched for 24 individually presented, one degree targets, randomly positioned in a 60 degrees noise background. Head and eye movements were allowed and the presentation time was unlimited. The test validity was investigated by correlating the detection times with the 'percentage of preferred walking speed' (PPWS) and the 'number of collisions' on an indoor mobility course. In PTV and STV, the detection times had significant negative correlation with the field of view. The detection times had significant positive relations with target location. In the STV, the detection time was significantly negatively correlated with the PPWS and significantly positively correlated with the collisions score on the indoor mobility course. In the PTV, the relationship was not statistically significant. No significant difference in performance of STV was found when repeating the test one to two weeks later. The proposed AVA test was sensitive to the field of view and target location. The test is unique in design, quick, simple to deliver and both repeatable and valid. It could be a valuable tool to test different rehabilitation strategies in patients with TV. © 2016 Optometry Australia.

  8. Bio-inspired approach for intelligent unattended ground sensors

    Science.gov (United States)

    Hueber, Nicolas; Raymond, Pierre; Hennequin, Christophe; Pichler, Alexander; Perrot, Maxime; Voisin, Philippe; Moeglin, Jean-Pierre

    2015-05-01

    Improving the surveillance capacity over wide zones requires a set of smart battery-powered Unattended Ground Sensors capable of issuing an alarm to a decision-making center. Only high-level information has to be sent when a relevant suspicious situation occurs. In this paper we propose an innovative bio-inspired approach that mimics the human bi-modal vision mechanism and the parallel processing ability of the human brain. The designed prototype exploits two levels of analysis: a low-level panoramic motion analysis, the peripheral vision, and a high-level event-focused analysis, the foveal vision. By tracking moving objects and fusing multiple criteria (size, speed, trajectory, etc.), the peripheral vision module acts as a fast relevant event detector. The foveal vision module focuses on the detected events to extract more detailed features (texture, color, shape, etc.) in order to improve the recognition efficiency. The implemented recognition core is able to acquire human knowledge and to classify in real-time a huge amount of heterogeneous data thanks to its natively parallel hardware structure. This UGS prototype validates our system approach under laboratory tests. The peripheral analysis module demonstrates a low false alarm rate whereas the foveal vision correctly focuses on the detected events. A parallel FPGA implementation of the recognition core succeeds in fulfilling the embedded application requirements. These results are paving the way of future reconfigurable virtual field agents. By locally processing the data and sending only high-level information, their energy requirements and electromagnetic signature are optimized. Moreover, the embedded Artificial Intelligence core enables these bio-inspired systems to recognize and learn new significant events. By duplicating human expertise in potentially hazardous places, our miniature visual event detector will allow early warning and contribute to better human decision making.

  9. Stereo Vision Inside Tire

    Science.gov (United States)

    2015-08-21

    1 Stereo Vision Inside Tire P.S. Els C.M. Becker University of Pretoria W911NF-14-1-0590 Final...Stereo Vision Inside Tire 5a. CONTRACT NUMBER W911NF-14-1-0590 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Prof PS Els CM...on the development of a stereo vision system that can be mounted inside a rolling tire , known as T2-CAM for Tire -Terrain CAMera. The T2-CAM system

  10. Copenhagen Energy Vision

    DEFF Research Database (Denmark)

    Mathiesen, Brian Vad; Lund, Rasmus Søgaard; Connolly, David

    The short-term goal for The City of Copenhagen is a CO2 neutral energy supply by the year 2025, and the long-term vision for Denmark is a 100% renewable energy (RE) supply by the year 2050. In this project, it is concluded that Copenhagen plays a key role in this transition. The long-term vision...

  11. Vision/INS Integrated Navigation System for Poor Vision Navigation Environments

    Directory of Open Access Journals (Sweden)

    Youngsun Kim

    2016-10-01

    Full Text Available In order to improve the performance of an inertial navigation system, many aiding sensors can be used. Among these aiding sensors, a vision sensor is of particular note due to its benefits in terms of weight, cost, and power consumption. This paper proposes an inertial and vision integrated navigation method for poor vision navigation environments. The proposed method uses focal plane measurements of landmarks in order to provide position, velocity and attitude outputs even when the number of landmarks on the focal plane is not enough for navigation. In order to verify the proposed method, computer simulations and van tests are carried out. The results show that the proposed method gives accurate and reliable position, velocity and attitude outputs when the number of landmarks is insufficient.

  12. Governance and Vision: Visions of Cities towards a low-energy future

    International Nuclear Information System (INIS)

    Pares-Ramos, Isabel K.; Dupas, Stephane

    2010-07-01

    The overall aim of this report was to identify and review the process by which different cities have built visionary plans for the long-term sustainable development of their territory for a low-energy, climate-resilient future. We used a case studies approach to describe different methods used by cities to build their visionary plans and address present energy and climate change challenges. The purpose of this report is as well to contribute to the debate on the future of cities in the post-carbon society and to inspire further initiatives for a low-energy future. The first step towards understanding the visioning/planning process of cities for a low-energy future was to identify several initiatives were cities have developed a plan or statement to address energy and climate change issues in the next 20 to 50 years. These plans and documents were then reviewed in search of diverse and innovative methods and process for visioning, design and planning towards a low-carbon future. After these preliminary assessments and observations, we selected 4 cities based on the use of different methodologies for visioning, planning and development of the action plan and projects. Afterwards, we focused on the description of the visioning/planning process per city, based on information obtained from official plans and documents, and from interviews with local authorities and other personnel working for projects in each of the cities selected. The content of the interviews varied according to the local context of the initiative, but in general contained questions regarding methods and tools used to build their visions and action plans, as well as enquiries about the visioning steps and process, the role of stakeholders, and implementation strategies used to drive forward this initiatives

  13. Drug-induced peripheral neuropathy

    DEFF Research Database (Denmark)

    Vilholm, Ole Jakob; Christensen, Alex Alban; Zedan, Ahmed

    2014-01-01

    Peripheral neuropathy can be caused by medication, and various descriptions have been applied for this condition. In this MiniReview, the term 'drug-induced peripheral neuropathy' (DIPN) is used with the suggested definition: Damage to nerves of the peripheral nervous system caused by a chemical...... substance used in the treatment, cure, prevention or diagnosis of a disease. Optic neuropathy is included in this definition. A distinction between DIPN and other aetiologies of peripheral neuropathy is often quite difficult and thus, the aim of this MiniReview is to discuss the major agents associated...

  14. Validation of vision-based obstacle detection algorithms for low-altitude helicopter flight

    Science.gov (United States)

    Suorsa, Raymond; Sridhar, Banavar

    1991-01-01

    A validation facility being used at the NASA Ames Research Center is described which is aimed at testing vision based obstacle detection and range estimation algorithms suitable for low level helicopter flight. The facility is capable of processing hundreds of frames of calibrated multicamera 6 degree-of-freedom motion image sequencies, generating calibrated multicamera laboratory images using convenient window-based software, and viewing range estimation results from different algorithms along with truth data using powerful window-based visualization software.

  15. Molecular Detection of Neuron-Specific ELAV-Like-Positive Cells in the Peripheral Blood of Patients with Small-Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Vito D’Alessandro

    2008-01-01

    Full Text Available Background: n-ELAV (neuronal-Embryonic Lethal, Abnormal Vision-like genes belong to a family codifying for onconeural RNA-binding proteins. Anti-Hu-antibodies (anti-Hu-Ab are typically associated with paraneoplastic encephalomyelitis/sensory neuropathy (PEM/PSN, and low titres of anti-Hu-Ab, were found in newly diagnosed Small Cell Lung Cancer (SCLC. The aim of this study is to develop a sensitive and quantitative molecular real-time PCR assay to detect SCLC cells in peripheral blood (PB through nELAV-like transcripts quantification.

  16. Operational modal analysis on a VAWT in a large wind tunnel using stereo vision technique

    International Nuclear Information System (INIS)

    Najafi, Nadia; Paulsen, Uwe Schmidt

    2017-01-01

    This paper is about development and use of a research based stereo vision system for vibration and operational modal analysis on a parked, 1-kW, 3-bladed vertical axis wind turbine (VAWT), tested in a wind tunnel at high wind. Vibrations were explored experimentally by tracking small deflections of the markers on the structure with two cameras, and also numerically, to study structural vibrations in an overall objective to investigate challenges and to prove the capability of using stereo vision. Two high speed cameras provided displacement measurements at no wind speed interference. The displacement time series were obtained using a robust image processing algorithm and analyzed with data-driven stochastic subspace identification (DD-SSI) method. In addition of exploring structural behaviour, the VAWT testing gave us the possibility to study aerodynamic effects at Reynolds number of approximately 2 × 10"5. VAWT dynamics were simulated using HAWC2. The stereo vision results and HAWC2 simulations agree within 4% except for mode 3 and 4. The high aerodynamic damping of one of the blades, in flatwise motion, would explain the gap between those two modes from simulation and stereo vision. A set of conventional sensors, such as accelerometers and strain gauges, are also measuring rotor vibration during the experiment. The spectral analysis of the output signals of the conventional sensors agrees the stereo vision results within 4% except for mode 4 which is due to the inaccuracy of spectral analysis in picking very closely spaced modes. Finally, the uncertainty of the 3D displacement measurement was evaluated by applying a generalized method based on the law of error propagation, for a linear camera model of the stereo vision system. - Highlights: • The stereo vision technique is used to track deflections on a VAWT in the wind tunnel. • OMA is applied on displacement time series to study the dynamic behaviour of the VAWT. • Stereo vision results enabled us to

  17. Vision and Control for UAVs: A Survey of General Methods andof Inexpensive Platforms for Infrastructure Inspection

    Directory of Open Access Journals (Sweden)

    Koppány Máthé

    2015-06-01

    Full Text Available Unmanned aerial vehicles (UAVs have gained significant attention in recent years. Low-cost platforms using inexpensive sensor payloads have been shown to provide satisfactory flight and navigation capabilities. In this report, we survey vision and control methods that can be applied to low-cost UAVs, and we list some popular inexpensive platforms and application fields where they are useful. We also highlight the sensor suites used where this information is available. We overview, among others, feature detection and tracking, optical flow and visual servoing, low-level stabilization and high-level planning methods. We then list popular low-cost UAVs, selecting mainly quadrotors. We discuss applications, restricting our focus to the field of infrastructure inspection. Finally, as an example, we formulate two use-cases for railway inspection, a less explored application field, and illustrate the usage of the vision and control techniques reviewed by selecting appropriate ones to tackle these use-cases. To select vision methods, we run a thorough set of experimental evaluations.

  18. The Pedagogy of Teaching Educational Vision: A Vision Coach's Field Notes about Leaders as Learners

    Science.gov (United States)

    Schein, Jeffrey

    2009-01-01

    The emerging field of educational visioning is full of challenges and phenomena worthy of careful analysis and documentation. A relatively neglected phenomenon is the learning curve of the leaders (often lay leaders) involved in the visioning process. This article documents a range of experiences of the author serving as a vision coach to five…

  19. Low vision and mobility scooters: the experiences of individuals with low vision who use mobility scooters.

    Science.gov (United States)

    McMullan, Keri S; Butler, Mary

    2018-05-09

    Older adults with low vision are a growing population with rehabilitation needs including support with community mobility to enable community participation. Some older adults with low vision choose to use mobility scooters to mobilize within their community, but there is limited research about the use by people with low vision. This paper describes a pilot study and asks the question: what are the experiences of persons with low vision who use mobility scooters? This study gathered the experiences of four participants with low vision, aged 51 and over, who regularly use mobility scooters. Diverse methods were used including a go-along, a semi-structured interview and a new measure of functional vision for mobility called the vision-related outcomes in orientation and mobility (VROOM). Four themes were found to describe experiences: autonomy and well-being, accessibility, community interactions and self-regulation. Discussion and implications: This study was a pilot for a larger study examining self-regulation in scooter users. However, as roles emerge for health professionals and scooters, the findings also provide evidence to inform practice, because it demonstrates the complex meaning and influences on performance involved in low vision mobility scooter use. Implications for rehabilitation Scooter use supports autonomy and well-being and community connections for individuals with both mobility and visual impairments. Low vision scooter users demonstrate self-regulation of their scooter use to manage both their visual and environmental limitations. Issues of accessibility experienced by this sample affect a wider community of footpath users, emphasizing the need for councils to address inadequate infrastructure. Rehabilitators can support their low vision clients' scooter use by acknowledging issues of accessibility and promoting self-regulation strategies to manage risks and barriers.

  20. Transplantation of olfactory ensheathing cells as adjunct cell therapy for peripheral nerve injury.

    Science.gov (United States)

    Radtke, Christine; Wewetzer, Konstantin; Reimers, Kerstin; Vogt, Peter M

    2011-01-01

    Traumatic events, such as work place trauma or motor vehicle accident violence, result in a significant number of severe peripheral nerve lesions, including nerve crush and nerve disruption defects. Transplantation of myelin-forming cells, such as Schwann cells (SCs) or olfactory ensheathing cells (OECs), may be beneficial to the regenerative process because the applied cells could mediate neurotrophic and neuroprotective effects by secretion of chemokines. Moreover, myelin-forming cells are capable of bridging the repair site by establishing an environment permissive to axonal regeneration. The cell types that are subject to intense investigation include SCs and OECs either derived from the olfactory bulb or the olfactory mucosa, stromal cells from bone marrow (mesenchymal stem cells, MSCs), and adipose tissue-derived cells. OECs reside in the peripheral and central nervous system and have been suggested to display unique regenerative properties. However, so far OECs were mainly used in experimental studies to foster central regeneration and it was not until recently that their regeneration-promoting activity for the peripheral nervous system was recognized. In the present review, we summarize recent experimental evidence regarding the regenerative effects of OECs applied to the peripheral nervous system that may be relevant to design novel autologous cell transplantation therapies. © 2011 Cognizant Comm. Corp.

  1. Case Report: Use of Sports and Performance Vision Training to Benefit a Low-vision Patient's Function.

    Science.gov (United States)

    Laby, Daniel M

    2018-05-17

    Despite our inability to attenuate the course of many ocular diseases that can ultimately lead to loss or significantly decreased visual function, this report describes a potential technique to aid such patients in maximizing the use of the vision that remains. The aim of this study was to demonstrate the applicability of utilizing sports vision training to improve objective and subjective visuomotor function in a low-vision patient. A 37-year-old woman with Usher syndrome presented with reduced central visual acuity and visual field. Although we were unable to reverse the damage resulting from her diagnosis, we were able to improve the use of the remaining vision. A 27 to 31% improvement in hand-eye coordination was achieved along with a 41% improvement in object tracking and visual concentration. Most importantly, following the 14-week training period, there was also a subjective improvement in the patient's appreciation of her visual ability. The sports vision literature cites many examples in which sports vision training is useful in improving visuomotor and on-field performance. We hypothesized that these techniques may be used to aid not only athletes but also patients with low vision. Despite suffering from reduced acuity and a limited visual field, these patients often still have a significant amount of vision ability that can be used to guide motor actions. Using techniques to increase the efficient use of this remaining vision may reduce the impact of the reduced visual function and aid in activities of daily living.

  2. Visual acuity and contrast sensitivity are two important factors affecting vision-related quality of life in advanced age-related macular degeneration

    Science.gov (United States)

    Selivanova, Alexandra; Shin, Hyun Joon; Miller, Joan W.; Jackson, Mary Lou

    2018-01-01

    Purpose Vision loss from age-related macular degeneration (AMD) has a profound effect on vision-related quality of life (VRQoL). The pupose of this study is to identify clinical factors associated with VRQoL using the Rasch- calibrated NEI VFQ-25 scales in bilateral advanced AMD patients. Methods We retrospectively reviewed 47 patients (mean age 83.2 years) with bilateral advanced AMD. Clinical assessment included age, gender, type of AMD, high contrast visual acuity (VA), history of medical conditions, contrast sensitivity (CS), central visual field loss, report of Charles Bonnet Syndrome, current treatment for AMD and Rasch-calibrated NEI VFQ-25 visual function and socioemotional function scales. The NEI VFQ visual function scale includes items of general vision, peripheral vision, distance vision and near vision-related activity while the socioemotional function scale includes items of vision related-social functioning, role difficulties, dependency, and mental health. Multiple regression analysis (structural regression model) was performed using fixed item parameters obtained from the one-parameter item response theory model. Results Multivariate analysis showed that high contrast VA and CS were two factors influencing VRQoL visual function scale (β = -0.25, 95% CI-0.37 to -0.12, p<0.001 and β = 0.35, 95% CI 0.25 to 0.46, p<0.001) and socioemontional functioning scale (β = -0.2, 95% CI -0.37 to -0.03, p = 0.023, and β = 0.3, 95% CI 0.18 to 0.43, p = 0.001). Central visual field loss was not assoicated with either VRQoL visual or socioemontional functioning scale (β = -0.08, 95% CI-0.28 to 0.12,p = 0.44 and β = -0.09, 95% CI -0.03 to 0.16, p = 0.50, respectively). Conclusion In patients with vision impairment secondary to bilateral advanced AMD, high contrast VA and CS are two important factors affecting VRQoL. PMID:29746512

  3. A design approach for small vision-based autonomous vehicles

    Science.gov (United States)

    Edwards, Barrett B.; Fife, Wade S.; Archibald, James K.; Lee, Dah-Jye; Wilde, Doran K.

    2006-10-01

    This paper describes the design of a small autonomous vehicle based on the Helios computing platform, a custom FPGA-based board capable of supporting on-board vision. Target applications for the Helios computing platform are those that require lightweight equipment and low power consumption. To demonstrate the capabilities of FPGAs in real-time control of autonomous vehicles, a 16 inch long R/C monster truck was outfitted with a Helios board. The platform provided by such a small vehicle is ideal for testing and development. The proof of concept application for this autonomous vehicle was a timed race through an environment with obstacles. Given the size restrictions of the vehicle and its operating environment, the only feasible on-board sensor is a small CMOS camera. The single video feed is therefore the only source of information from the surrounding environment. The image is then segmented and processed by custom logic in the FPGA that also controls direction and speed of the vehicle based on visual input.

  4. Equality of What? The Capability Approach and the Right to Education for Persons with Disabilities

    Directory of Open Access Journals (Sweden)

    Andrea Broderick

    2018-03-01

    Full Text Available The right to education is indispensable in unlocking other substantive human rights and in ensuring full and equal participation of persons with disabilities in mainstream society. The cornerstone of Article 24 of the United Nations Convention on the Rights of Persons with Disabilities seeks to ensure access to inclusive education for persons with disabilities on an equal basis with others as well as the full development of human potential. Since the adoption of the Convention, there has been much theorising about inclusive education; however, there has been little focus on the meaning of equality in the context of the right to education for persons with disabilities. The capability approach, developed by Amartya Sen and further refined by Martha Nussbaum, focuses on ensuring equality and developing human potential. It is often viewed as a tool that can be used to overcome the limitations of traditional equality assessments in the educational sphere, which only measure resources and outcomes. This article explores whether the capability approach can offer new insights into the vision of educational equality contained in the Convention and how that vision can be implemented at the national level.

  5. Vision in water.

    Science.gov (United States)

    Atchison, David A; Valentine, Emma L; Gibson, Georgina; Thomas, Hannah R; Oh, Sera; Pyo, Young Ah; Lacherez, Philippe; Mathur, Ankit

    2013-09-06

    The purpose of this study is to determine visual performance in water, including the influence of pupil size. The water environment was simulated by placing goggles filled with saline in front of the eyes with apertures placed at the front of the goggles. Correction factors were determined for the different magnification under this condition in order to estimate vision in water. Experiments were conducted on letter visual acuity (seven participants), grating resolution (eight participants), and grating contrast sensitivity (one participant). For letter acuity, mean loss of vision in water, compared to corrected vision in air, varied between 1.1 log min of arc resolution (logMAR) for a 1 mm aperture to 2.2 logMAR for a 7 mm aperture. The vision in min of arc was described well by a linear relationship with pupil size. For grating acuity, mean loss varied between 1.1 logMAR for a 2 mm aperture to 1.2 logMAR for a 6 mm aperture. Contrast sensitivity for a 2 mm aperture deteriorated as spatial frequency increased with a 2 log unit loss by 3 c/°. Superimposed on this deterioration were depressions (notches) in sensitivity with the first three notches occurring at 0.45, 0.8, and 1.3 c/° with estimates for water of 0.39, 0.70, and 1.13 c/°. In conclusion, vision in water is poor. It becomes worse as pupil size increases, but the effects are much more marked for letter targets than for grating targets.

  6. Restoration of sensory dysfunction following peripheral nerve injury by the polysaccharide from culinary and medicinal mushroom, Hericium erinaceus (Bull.: Fr. Pers. through its neuroregenerative action

    Directory of Open Access Journals (Sweden)

    Kah-Hui WONG

    2015-01-01

    Full Text Available Abstract Peripheral nerves have the unique capability to regenerate after injury. Insights into regeneration of peripheral nerves after injury may have implications for neurodegenerative diseases of the nervous system. We investigated the ability of polysaccharide from Hericium erinaceus mushroom in the treatment of nerve injury following peroneal nerve crush in Sprague-Dawley rats by daily oral administration. In sensory functional recovery test, the time taken for the rats to withdraw its hind limb from contact with the hot plate was measured. The test revealed acceleration of sensory recovery in the polysaccharide group compared to negative controls. Further, peripheral nerve injury leads to changes at the remotely located DRG containing cell bodies of sensory neurons. Immunofluorescence studies showed that Akt and p38 MAPK were expressed in DRG and strongly upregulated in polysaccharide group after peripheral nerve injury. The intensity of endothelial cells antigen-1 that recognized endothelial cells in the blood vessels of distal segments in crushed nerves was significantly higher in the treated groups than in the negative control group. Our findings suggest that H. erinaceus is capable of accelerating sensory functional recovery after peripheral nerve injury and the effect involves the activation of protein kinase signaling pathways and restoration of blood-nerve barrier.

  7. Bio-inspired vision

    International Nuclear Information System (INIS)

    Posch, C

    2012-01-01

    Nature still outperforms the most powerful computers in routine functions involving perception, sensing and actuation like vision, audition, and motion control, and is, most strikingly, orders of magnitude more energy-efficient than its artificial competitors. The reasons for the superior performance of biological systems are subject to diverse investigations, but it is clear that the form of hardware and the style of computation in nervous systems are fundamentally different from what is used in artificial synchronous information processing systems. Very generally speaking, biological neural systems rely on a large number of relatively simple, slow and unreliable processing elements and obtain performance and robustness from a massively parallel principle of operation and a high level of redundancy where the failure of single elements usually does not induce any observable system performance degradation. In the late 1980's, Carver Mead demonstrated that silicon VLSI technology can be employed in implementing ''neuromorphic'' circuits that mimic neural functions and fabricating building blocks that work like their biological role models. Neuromorphic systems, as the biological systems they model, are adaptive, fault-tolerant and scalable, and process information using energy-efficient, asynchronous, event-driven methods. In this paper, some basics of neuromorphic electronic engineering and its impact on recent developments in optical sensing and artificial vision are presented. It is demonstrated that bio-inspired vision systems have the potential to outperform conventional, frame-based vision acquisition and processing systems in many application fields and to establish new benchmarks in terms of redundancy suppression/data compression, dynamic range, temporal resolution and power efficiency to realize advanced functionality like 3D vision, object tracking, motor control, visual feedback loops, etc. in real-time. It is argued that future artificial vision systems

  8. Virtual Vision

    Science.gov (United States)

    Terzopoulos, Demetri; Qureshi, Faisal Z.

    Computer vision and sensor networks researchers are increasingly motivated to investigate complex multi-camera sensing and control issues that arise in the automatic visual surveillance of extensive, highly populated public spaces such as airports and train stations. However, they often encounter serious impediments to deploying and experimenting with large-scale physical camera networks in such real-world environments. We propose an alternative approach called "Virtual Vision", which facilitates this type of research through the virtual reality simulation of populated urban spaces, camera sensor networks, and computer vision on commodity computers. We demonstrate the usefulness of our approach by developing two highly automated surveillance systems comprising passive and active pan/tilt/zoom cameras that are deployed in a virtual train station environment populated by autonomous, lifelike virtual pedestrians. The easily reconfigurable virtual cameras distributed in this environment generate synthetic video feeds that emulate those acquired by real surveillance cameras monitoring public spaces. The novel multi-camera control strategies that we describe enable the cameras to collaborate in persistently observing pedestrians of interest and in acquiring close-up videos of pedestrians in designated areas.

  9. UNDERSTANDING AND PREVENTING COMPUTER VISION SYNDROME

    OpenAIRE

    REDDY SC; LOH KY

    2008-01-01

    The invention of computer and advancement in information technology has revolutionized and benefited the society but at the same time has caused symptoms related to its usage such as ocular sprain, irritation, redness, dryness, blurred vision and double vision. This cluster of symptoms is known as computer vision syndrome which is characterized by the visual symptoms which result from interaction with computer display or its environment. Three major mechanisms that lead to computer vision syn...

  10. Color Vision in Aniridia.

    Science.gov (United States)

    Pedersen, Hilde R; Hagen, Lene A; Landsend, Erlend C S; Gilson, Stuart J; Utheim, Øygunn A; Utheim, Tor P; Neitz, Maureen; Baraas, Rigmor C

    2018-04-01

    To assess color vision and its association with retinal structure in persons with congenital aniridia. We included 36 persons with congenital aniridia (10-66 years), and 52 healthy, normal trichromatic controls (10-74 years) in the study. Color vision was assessed with Hardy-Rand-Rittler (HRR) pseudo-isochromatic plates (4th ed., 2002); Cambridge Color Test and a low-vision version of the Color Assessment and Diagnosis test (CAD-LV). Cone-opsin genes were analyzed to confirm normal versus congenital color vision deficiencies. Visual acuity and ocular media opacities were assessed. The central 30° of both eyes were imaged with the Heidelberg Spectralis OCT2 to grade the severity of foveal hypoplasia (FH, normal to complete: 0-4). Five participants with aniridia had cone opsin genes conferring deutan color vision deficiency and were excluded from further analysis. Of the 31 with aniridia and normal opsin genes, 11 made two or more red-green (RG) errors on HRR, four of whom also made yellow-blue (YB) errors; one made YB errors only. A total of 19 participants had higher CAD-LV RG thresholds, of which eight also had higher CAD-LV YB thresholds, than normal controls. In aniridia, the thresholds were higher along the RG than the YB axis, and those with a complete FH had significantly higher RG thresholds than those with mild FH (P = 0.038). Additional increase in YB threshold was associated with secondary ocular pathology. Arrested foveal formation and associated alterations in retinal processing are likely to be the primary reason for impaired red-green color vision in aniridia.

  11. Lambda Vision

    Science.gov (United States)

    Czajkowski, Michael

    2014-06-01

    There is an explosion in the quantity and quality of IMINT data being captured in Intelligence Surveillance and Reconnaissance (ISR) today. While automated exploitation techniques involving computer vision are arriving, only a few architectures can manage both the storage and bandwidth of large volumes of IMINT data and also present results to analysts quickly. Lockheed Martin Advanced Technology Laboratories (ATL) has been actively researching in the area of applying Big Data cloud computing techniques to computer vision applications. This paper presents the results of this work in adopting a Lambda Architecture to process and disseminate IMINT data using computer vision algorithms. The approach embodies an end-to-end solution by processing IMINT data from sensors to serving information products quickly to analysts, independent of the size of the data. The solution lies in dividing up the architecture into a speed layer for low-latent processing and a batch layer for higher quality answers at the expense of time, but in a robust and fault-tolerant way. This approach was evaluated using a large corpus of IMINT data collected by a C-130 Shadow Harvest sensor over Afghanistan from 2010 through 2012. The evaluation data corpus included full motion video from both narrow and wide area field-of-views. The evaluation was done on a scaled-out cloud infrastructure that is similar in composition to those found in the Intelligence Community. The paper shows experimental results to prove the scalability of the architecture and precision of its results using a computer vision algorithm designed to identify man-made objects in sparse data terrain.

  12. Machine-vision based optofluidic cell sorting

    DEFF Research Database (Denmark)

    Glückstad, Jesper; Bañas, Andrew

    the available light and creating 2D or 3D beam distributions aimed at the positions of the detected cells. Furthermore, the beam shaping freedom provided by GPC can allow optimizations in the beam’s propagation and its interaction with the laser catapulted and sorted cells....... machine vision1. This approach is gentler, less invasive and more economical compared to conventional FACS-systems. As cells are less responsive to plastic or glass objects commonly used in the optical manipulation literature2, and since laser safety would be an issue in clinical use, we develop efficient...... approaches in utilizing lasers and light modulation devices. The Generalized Phase Contrast (GPC) method3-9 that can be used for efficiently illuminating spatial light modulators10 or creating well-defined contiguous optical traps11 is supplemented by diffractive techniques capable of integrating...

  13. Ultraviolet vision in lacertid lizards: evidence from retinal structure, eye transmittance, SWS1 visual pigment genes and behaviour.

    Science.gov (United States)

    Pérez i de Lanuza, Guillem; Font, Enrique

    2014-08-15

    Ultraviolet (UV) vision and UV colour patches have been reported in a wide range of taxa and are increasingly appreciated as an integral part of vertebrate visual perception and communication systems. Previous studies with Lacertidae, a lizard family with diverse and complex coloration, have revealed the existence of UV-reflecting patches that may function as social signals. However, confirmation of the signalling role of UV coloration requires demonstrating that the lizards are capable of vision in the UV waveband. Here we use a multidisciplinary approach to characterize the visual sensitivity of a diverse sample of lacertid species. Spectral transmission measurements of the ocular media show that wavelengths down to 300 nm are transmitted in all the species sampled. Four retinal oil droplet types can be identified in the lacertid retina. Two types are pigmented and two are colourless. Fluorescence microscopy reveals that a type of colourless droplet is UV-transmitting and may thus be associated with UV-sensitive cones. DNA sequencing shows that lacertids have a functional SWS1 opsin, very similar at 13 critical sites to that in the presumed ancestral vertebrate (which was UV sensitive) and other UV-sensitive lizards. Finally, males of Podarcis muralis are capable of discriminating between two views of the same stimulus that differ only in the presence/absence of UV radiance. Taken together, these results provide convergent evidence of UV vision in lacertids, very likely by means of an independent photopigment. Moreover, the presence of four oil droplet types suggests that lacertids have a four-cone colour vision system. © 2014. Published by The Company of Biologists Ltd.

  14. Jane Addams’ Social Vision

    DEFF Research Database (Denmark)

    Villadsen, Kaspar

    2018-01-01

    resonated with key tenets of social gospel theology, which imbued her texts with an overarching vision of humanity’s progressive history. It is suggested that Addams’ vision of a major transition in industrial society, one involving a BChristian renaissance^ and individuals’ transformation into Bsocialized...

  15. Computer vision for sports

    DEFF Research Database (Denmark)

    Thomas, Graham; Gade, Rikke; Moeslund, Thomas B.

    2017-01-01

    fixed to players or equipment is generally not possible. This provides a rich set of opportunities for the application of computer vision techniques to help the competitors, coaches and audience. This paper discusses a selection of current commercial applications that use computer vision for sports...

  16. 3D vision system for intelligent milking robot automation

    Science.gov (United States)

    Akhloufi, M. A.

    2013-12-01

    In a milking robot, the correct localization and positioning of milking teat cups is of very high importance. The milking robots technology has not changed since a decade and is based primarily on laser profiles for teats approximate positions estimation. This technology has reached its limit and does not allow optimal positioning of the milking cups. Also, in the presence of occlusions, the milking robot fails to milk the cow. These problems, have economic consequences for producers and animal health (e.g. development of mastitis). To overcome the limitations of current robots, we have developed a new system based on 3D vision, capable of efficiently positioning the milking cups. A prototype of an intelligent robot system based on 3D vision for real-time positioning of a milking robot has been built and tested under various conditions on a synthetic udder model (in static and moving scenarios). Experimental tests, were performed using 3D Time-Of-Flight (TOF) and RGBD cameras. The proposed algorithms permit the online segmentation of teats by combing 2D and 3D visual information. The obtained results permit the teat 3D position computation. This information is then sent to the milking robot for teat cups positioning. The vision system has a real-time performance and monitors the optimal positioning of the cups even in the presence of motion. The obtained results, with both TOF and RGBD cameras, show the good performance of the proposed system. The best performance was obtained with RGBD cameras. This latter technology will be used in future real life experimental tests.

  17. Propylthiouracil and peripheral neuropathy

    Directory of Open Access Journals (Sweden)

    Valentina Van Boekel

    1992-06-01

    Full Text Available Peripheral neuropathy is a rare manifestation in hyperthyroidism. We describe the neurological manifestations of a 38 year old female with Graves' disease who developed peripheral neuropathy in the course of her treatment with propylthiouracil. After the drug was tapered off, the neurological signs disappeared. Therefore, we call attention for a possible toxic effect on peripheral nervous system caused by this drug.

  18. Impact of low vision rehabilitation on functional vision performance of children with visual impairment.

    Science.gov (United States)

    Ganesh, Suma; Sethi, Sumita; Srivastav, Sonia; Chaudhary, Amrita; Arora, Priyanka

    2013-09-01

    To evaluate the impact of low vision rehabilitation on functional vision of children with visual impairment. The LV Prasad-Functional Vision Questionnaire, designed specifically to measure functional performance of visually impaired children of developing countries, was used to assess the level of difficulty in performing various tasks pre and post visual rehabilitation in children with documented visual impairment. Chi-square test was used to assess the impact of rehabilitation intervention on functional vision performance; a P visual acuity prior to the introduction of low vision devices (LVDs) was 0.90 ± 0.05 for distance and for near it was 0.61 ± 0.05. After the intervention, the acuities improved significantly for distance (0.2 ± 0.27; P visual rehabilitation was especially found in those activities related to their studying lifestyle like copying from the blackboard (P visual rehabilitation, especially with those activities which are related to their academic output. It is important for these children to have an early visual rehabilitation to decrease the impairment associated with these decreased visual output and to enhance their learning abilities.

  19. Comparison of a multispectral vision system and a colorimeter for the assessment of meat color.

    Science.gov (United States)

    Trinderup, Camilla H; Dahl, Anders; Jensen, Kirsten; Carstensen, Jens Michael; Conradsen, Knut

    2015-04-01

    The color assessment ability of a multispectral vision system is investigated by a comparison study with color measurements from a traditional colorimeter. The experiment involves fresh and processed meat samples. Meat is a complex material; heterogeneous with varying scattering and reflectance properties, so several factors can influence the instrumental assessment of meat color. In order to assess whether two methods are equivalent, the variation due to these factors must be taken into account. A statistical analysis was conducted and showed that on a calibration sheet the two instruments are equally capable of measuring color. Moreover the vision system provides a more color rich assessment of fresh meat samples with a glossier surface, than the colorimeter. Careful studies of the different sources of variation enable an assessment of the order of magnitude of the variability between methods accounting for other sources of variation leading to the conclusion that color assessment using a multispectral vision system is superior to traditional colorimeter assessments. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Functional programming for computer vision

    Science.gov (United States)

    Breuel, Thomas M.

    1992-04-01

    Functional programming is a style of programming that avoids the use of side effects (like assignment) and uses functions as first class data objects. Compared with imperative programs, functional programs can be parallelized better, and provide better encapsulation, type checking, and abstractions. This is important for building and integrating large vision software systems. In the past, efficiency has been an obstacle to the application of functional programming techniques in computationally intensive areas such as computer vision. We discuss and evaluate several 'functional' data structures for representing efficiently data structures and objects common in computer vision. In particular, we will address: automatic storage allocation and reclamation issues; abstraction of control structures; efficient sequential update of large data structures; representing images as functions; and object-oriented programming. Our experience suggests that functional techniques are feasible for high- performance vision systems, and that a functional approach simplifies the implementation and integration of vision systems greatly. Examples in C++ and SML are given.

  1. Computer Vision Based Measurement of Wildfire Smoke Dynamics

    Directory of Open Access Journals (Sweden)

    BUGARIC, M.

    2015-02-01

    Full Text Available This article presents a novel method for measurement of wildfire smoke dynamics based on computer vision and augmented reality techniques. The aspect of smoke dynamics is an important feature in video smoke detection that could distinguish smoke from visually similar phenomena. However, most of the existing smoke detection systems are not capable of measuring the real-world size of the detected smoke regions. Using computer vision and GIS-based augmented reality, we measure the real dimensions of smoke plumes, and observe the change in size over time. The measurements are performed on offline video data with known camera parameters and location. The observed data is analyzed in order to create a classifier that could be used to eliminate certain categories of false alarms induced by phenomena with different dynamics than smoke. We carried out an offline evaluation where we measured the improvement in the detection process achieved using the proposed smoke dynamics characteristics. The results show a significant increase in algorithm performance, especially in terms of reducing false alarms rate. From this it follows that the proposed method for measurement of smoke dynamics could be used to improve existing smoke detection algorithms, or taken into account when designing new ones.

  2. Peripheral Neuropathy: Symptoms and Signs

    Science.gov (United States)

    ... Utah Research News Make a Difference Symptoms of Peripheral Neuropathy Print This Page Peripheral Neuropathy symptoms usually start ... more slowly over many years. The symptoms of peripheral neuropathy often include: A sensation of wearing an invisible “ ...

  3. Development of Moire machine vision

    Science.gov (United States)

    Harding, Kevin G.

    1987-10-01

    Three dimensional perception is essential to the development of versatile robotics systems in order to handle complex manufacturing tasks in future factories and in providing high accuracy measurements needed in flexible manufacturing and quality control. A program is described which will develop the potential of Moire techniques to provide this capability in vision systems and automated measurements, and demonstrate artificial intelligence (AI) techniques to take advantage of the strengths of Moire sensing. Moire techniques provide a means of optically manipulating the complex visual data in a three dimensional scene into a form which can be easily and quickly analyzed by computers. This type of optical data manipulation provides high productivity through integrated automation, producing a high quality product while reducing computer and mechanical manipulation requirements and thereby the cost and time of production. This nondestructive evaluation is developed to be able to make full field range measurement and three dimensional scene analysis.

  4. Vision drives correlated activity without patterned spontaneous activity in developing Xenopus retina.

    Science.gov (United States)

    Demas, James A; Payne, Hannah; Cline, Hollis T

    2012-04-01

    Developing amphibians need vision to avoid predators and locate food before visual system circuits fully mature. Xenopus tadpoles can respond to visual stimuli as soon as retinal ganglion cells (RGCs) innervate the brain, however, in mammals, chicks and turtles, RGCs reach their central targets many days, or even weeks, before their retinas are capable of vision. In the absence of vision, activity-dependent refinement in these amniote species is mediated by waves of spontaneous activity that periodically spread across the retina, correlating the firing of action potentials in neighboring RGCs. Theory suggests that retinorecipient neurons in the brain use patterned RGC activity to sharpen the retinotopy first established by genetic cues. We find that in both wild type and albino Xenopus tadpoles, RGCs are spontaneously active at all stages of tadpole development studied, but their population activity never coalesces into waves. Even at the earliest stages recorded, visual stimulation dominates over spontaneous activity and can generate patterns of RGC activity similar to the locally correlated spontaneous activity observed in amniotes. In addition, we show that blocking AMPA and NMDA type glutamate receptors significantly decreases spontaneous activity in young Xenopus retina, but that blocking GABA(A) receptor blockers does not. Our findings indicate that vision drives correlated activity required for topographic map formation. They further suggest that developing retinal circuits in the two major subdivisions of tetrapods, amphibians and amniotes, evolved different strategies to supply appropriately patterned RGC activity to drive visual circuit refinement. Copyright © 2011 Wiley Periodicals, Inc.

  5. Computer Vision for Timber Harvesting

    DEFF Research Database (Denmark)

    Dahl, Anders Lindbjerg

    The goal of this thesis is to investigate computer vision methods for timber harvesting operations. The background for developing computer vision for timber harvesting is to document origin of timber and to collect qualitative and quantitative parameters concerning the timber for efficient harvest...... segments. The purpose of image segmentation is to make the basis for more advanced computer vision methods like object recognition and classification. Our second method concerns image classification and we present a method where we classify small timber samples to tree species based on Active Appearance...... to the development of the logTracker system the described methods have a general applicability making them useful for many other computer vision problems....

  6. A cost-effective intelligent robotic system with dual-arm dexterous coordination and real-time vision

    Science.gov (United States)

    Marzwell, Neville I.; Chen, Alexander Y. K.

    1991-01-01

    Dexterous coordination of manipulators based on the use of redundant degrees of freedom, multiple sensors, and built-in robot intelligence represents a critical breakthrough in development of advanced manufacturing technology. A cost-effective approach for achieving this new generation of robotics has been made possible by the unprecedented growth of the latest microcomputer and network systems. The resulting flexible automation offers the opportunity to improve the product quality, increase the reliability of the manufacturing process, and augment the production procedures for optimizing the utilization of the robotic system. Moreover, the Advanced Robotic System (ARS) is modular in design and can be upgraded by closely following technological advancements as they occur in various fields. This approach to manufacturing automation enhances the financial justification and ensures the long-term profitability and most efficient implementation of robotic technology. The new system also addresses a broad spectrum of manufacturing demand and has the potential to address both complex jobs as well as highly labor-intensive tasks. The ARS prototype employs the decomposed optimization technique in spatial planning. This technique is implemented to the framework of the sensor-actuator network to establish the general-purpose geometric reasoning system. The development computer system is a multiple microcomputer network system, which provides the architecture for executing the modular network computing algorithms. The knowledge-based approach used in both the robot vision subsystem and the manipulation control subsystems results in the real-time image processing vision-based capability. The vision-based task environment analysis capability and the responsive motion capability are under the command of the local intelligence centers. An array of ultrasonic, proximity, and optoelectronic sensors is used for path planning. The ARS currently has 18 degrees of freedom made up by two

  7. Night Vision Manual for the Flight Surgeon.

    Science.gov (United States)

    1985-08-01

    macula and fovea centralis. 4. Duality theory of vision-extends sensitivity of vision over 100,000 times (Fig. 12). ~Im Uilting Ullmlrage WVIVIWCentral...lowered night vision capa- bilities due to disease or degenerations . F. Hypoxia 1. Decrement of central vision due to 02 lack is quite small; such as, at

  8. Gait disorder rehabilitation using vision and non-vision based sensors: A systematic review

    Directory of Open Access Journals (Sweden)

    Asraf Ali

    2012-08-01

    Full Text Available Even though the amount of rehabilitation guidelines has never been greater, uncertainty continues to arise regarding the efficiency and effectiveness of the rehabilitation of gait disorders. This question has been hindered by the lack of information on accurate measurements of gait disorders. Thus, this article reviews the rehabilitation systems for gait disorder using vision and non-vision sensor technologies, as well as the combination of these. All papers published in the English language between 1990 and June, 2012 that had the phrases “gait disorder” “rehabilitation”, “vision sensor”, or “non vision sensor” in the title, abstract, or keywords were identified from the SpringerLink, ELSEVIER, PubMed, and IEEE databases. Some synonyms of these phrases and the logical words “and” “or” and “not” were also used in the article searching procedure. Out of the 91 published articles found, this review identified 84 articles that described the rehabilitation of gait disorders using different types of sensor technologies. This literature set presented strong evidence for the development of rehabilitation systems using a markerless vision-based sensor technology. We therefore believe that the information contained in this review paper will assist the progress of the development of rehabilitation systems for human gait disorders.

  9. Nuclear Research and Development Capabilities Needed to Support Future Growth

    Energy Technology Data Exchange (ETDEWEB)

    Wham, Robert M. [ORNL, P.O. Box 2008, Oak Ridge, TN 37831-6154 (United States); Kearns, Paul [Battelle Memorial Institute (United States); Marston, Ted [Marston Consulting (United States)

    2009-06-15

    The energy crisis looming before the United States can be resolved only by an approach that integrates a 'portfolio' of options. Nuclear energy, already an important element in the portfolio, should play an even more significant role in the future as the U.S. strives to attain energy independence and reduce carbon emissions. The DOE Office of Nuclear Energy asked Battelle Memorial Institute to obtain input from the commercial power generation industry on industry's vision for nuclear energy over the next 30-50 years. With this input, Battelle was asked to generate a set of research and development capabilities necessary for DOE to support the anticipated growth in nuclear power generation. This presentation, based on the report generated for the Office of Nuclear Energy, identifies the current and future nuclear research and development capabilities required to make this happen. The capabilities support: (1) continued, safe operation of the current fleet of nuclear plants; (2) the availability of a well qualified and trained workforce; (3) demonstration of the next generation nuclear plants; (4) development of a sustainable fuel cycle; (5) advanced technologies for maximizing resource utilization and minimization of waste and (6) advanced modeling and simulation for rapid and reliable development and deployment of new nuclear technologies. In order to assure these capabilities are made available, a Strategic Nuclear Energy Capability Initiative is proposed to provide the required resources during this critical period of time. (authors)

  10. Donating Peripheral Blood Stem Cells

    Science.gov (United States)

    ... Print this page My Cart Donating peripheral blood stem cells Peripheral blood stem cell (PBSC) donation is a nonsurgical procedure to collect ... Donating bone marrow Donor experiences videos Peripheral blood stem cell (PBSC) donation is one of two methods of ...

  11. The Trickle-Down Effect of Institutional Vision: Vision Statements and Academic Advising

    Science.gov (United States)

    Abelman, Robert; Atkin, David; Dalessandro, Amy; Snyder-Suhy, Sharon; Janstova, Patricie

    2007-01-01

    A description of the kinds of educated humans to be cultivated at a particular institution can be found in the college or university vision statement. The extent that vision is reflected in the governing models of advising operations, known by personnel, and transformed into day-to-day activities was assessed through a NACADA membership survey.…

  12. Ensuring US National Aeronautics Test Capabilities

    Science.gov (United States)

    Marshall, Timothy J.

    2010-01-01

    process; and the reductions in wind tunnel testing requirements within the largest consumer of ATP wind tunnel test time, the Aeronautics Research Mission Directorate (ARMD). Retirement of the Space Shuttle Program and recent perturbations of NASA's Constellation Program will exacerbate this downward trend. Therefore it is crucial that ATP periodically revisit and determine which of its test capabilities are strategically important, which qualify as low-risk redundancies that could be put in an inactive status or closed, and address the challenges associated with both sustainment and improvements to the test capabilities that must remain active. This presentation will provide an overview of the ATP vision, mission, and goals as well as the challenges and opportunities the program is facing both today and in the future. We will discuss the strategy ATP is taking over the next five years to address the National aeronautics test capability challenges and what the program will do to capitalize on its opportunities to ensure a ready, robust and relevant portfolio of National aeronautics test capabilities.

  13. Lessons Learned from the Creation of a Center of Excellence in Low Vision and Vision Rehabilitation in Wenzhou, China

    Science.gov (United States)

    Marinoff, Rebecca; Heilberger, Michael H.

    2017-01-01

    A model Center of Excellence in Low Vision and Vision Rehabilitation was created in a health care setting in China utilizing an inter-institutional relationship with a United States optometric institution. Accomplishments of, limitations to, and stimuli to the provision of low vision and vision rehabilitation services are shared.

  14. Design and Development of Vision Based Blockage Clearance Robot for Sewer Pipes

    Directory of Open Access Journals (Sweden)

    Krishna Prasad Nesaian

    2012-03-01

    Full Text Available Robotic technology is one of the advanced technologies, which is capable of completing tasks at situations where humans are unable to reach, see or survive. The underground sewer pipelines are the major tools for the transportation of effluent water. A lot of troubles caused by blockage in sewer pipe will lead to overflow of effluent water, sanitation problems. So robotic vehicle that is capable of traveling at underneath effluent water determining blockage using ultrasonic sensors and clearing by means of drilling mechanism is done. In addition to that wireless camera is fixed which acts as a robot vision by which we can monitor video and capture images using MATLAB tool. Thus in this project a prototype model of underground sewer pipe blockage clearance robot with drilling type will be developed

  15. Vision based systems for UAV applications

    CERN Document Server

    Kuś, Zygmunt

    2013-01-01

    This monograph is motivated by a significant number of vision based algorithms for Unmanned Aerial Vehicles (UAV) that were developed during research and development projects. Vision information is utilized in various applications like visual surveillance, aim systems, recognition systems, collision-avoidance systems and navigation. This book presents practical applications, examples and recent challenges in these mentioned application fields. The aim of the book is to create a valuable source of information for researchers and constructors of solutions utilizing vision from UAV. Scientists, researchers and graduate students involved in computer vision, image processing, data fusion, control algorithms, mechanics, data mining, navigation and IC can find many valuable, useful and practical suggestions and solutions. The latest challenges for vision based systems are also presented.

  16. Peripheral visual feedback: a powerful means of supporting effective attention allocation in event-driven, data-rich environments.

    Science.gov (United States)

    Nikolic, M I; Sarter, N B

    2001-01-01

    Breakdowns in human-automation coordination in data-rich, event-driven domains such as aviation can be explained in part by a mismatch between the high degree of autonomy yet low observability of modern technology. To some extent, the latter is the result of an increasing reliance in feedback design on foveal vision--an approach that fails to support pilots in tracking system-induced changes and events in parallel with performing concurrent flight-related tasks. One possible solution to the problem is the distribution of tasks and information across sensory modalities and processing channels. A simulator study is presented that compared the effectiveness of current foveal feedback and two implementations of peripheral visual feedback for keeping pilots informed about uncommanded changes in the status of an automated cockpit system. Both peripheral visual displays resulted in higher detection rates and faster response times, without interfering with the performance of concurrent visual tasks any more than does currently available automation feedback. Potential applications include improved display designs that support effective attention allocation in a variety of complex dynamic environments, such as aviation, process control, and medicine.

  17. LATE VISION: PROCESSES AND EPISTEMIC STATUS

    Directory of Open Access Journals (Sweden)

    Athanassios eRaftopoulos

    2011-12-01

    Full Text Available In this paper, I examine the processes that occur in late vision and address the problem of whether late vision should be construed as a properly speaking perceptual stage, or as a thought-like discursive stage. Specifically, I argue that late vision, its (partly conceptual nature notwithstanding, neither is constituted by nor does it implicate what I call pure thoughts, that is, propositional structures that are formed in the cognitive areas of the brain through, and participate in, discursive reasoning and inferences. At the same time, the output of late vision, namely an explicit belief concerning the identity and category membership of an object (that is, a recognitional belief or its features, eventually enters into discursive reasoning. Using Jackendoff’s distinction between visual awareness, which characterizes perception, and visual understanding, which characterizes pure thought, I claim that the contents of late vision belong to visual awareness and not to visual understanding and that although late vision implicates beliefs, either implicit or explicit, these beliefs are hybrid visual/conceptual constructs and not pure thoughts. Distinguishing between these hybrid representations and pure thoughts and delineating the nature of the representations of late vision lays the ground for examining, among other things, the process of conceptualization that occurs in visual processing and the way concepts modulate perceptual content affecting either its representational or phenomenal character. I also do not discuss the epistemological relations between the representations of late vision and the perceptual judgments they ‘support’, or ‘guide’ or ‘render possible’ or ‘evidence’ or ‘entitle’. However, the specification of the epistemology of late vision lays the ground for attacking that problem as well.

  18. The sustainable nuclear energy technology platform. A vision report

    International Nuclear Information System (INIS)

    2007-01-01

    Nuclear fission energy can deliver safe, sustainable, competitive and practically carbon-free energy to Europe's citizens and industries. Within the framework of the Strategic Energy Technology Plan (SET Plan), the European Commission's stakeholders in this field have formulated a collective vision of the contributions this energy could make towards Europe's transition to a low-carbon energy mix by 2050, with the aim of integrating and expanding R and D capabilities in order to further this objective. The groundwork has been prepared by the stakeholders listed in Annex II, within the framework of two EURATOM FP6 (Sixth Framework Programme) Coordination Actions, namely SNF-TP (Sustainable Nuclear Fission Technology Platform) and PATEROS (Partitioning and Transmutation European Road-map for Sustainable Nuclear Energy), with contributions from Europe's technical safety organisations. This vision report prepares the launch of the European Technology Platform on Sustainable Nuclear Energy (SNE-TP). It proposes a vision for the short-, medium- and long-term development of nuclear fission energy technologies, with the aim of achieving a sustainable production of nuclear energy, a significant progress in economic performance, and a continuous improvement of safety levels as well as resistance to proliferation. In particular, this document proposes road-maps for the development and deployment of potentially sustainable nuclear technologies, as well as actions to harmonize Europe's training and education, whilst renewing its research infrastructures. Public acceptance is also an important issue for the development of nuclear energy. Therefore, research in the fields of nuclear installation safety, protection of workers and populations against radiation, management of all types of waste, and governance methodologies with public participation will be promoted. The proposed road-maps provide the backbone for a strategic research agenda (SRA) to maintain Europe's leadership in

  19. 3D-engineering of Cellularized Conduits for Peripheral Nerve Regeneration

    Science.gov (United States)

    Hu, Yu; Wu, Yao; Gou, Zhiyuan; Tao, Jie; Zhang, Jiumeng; Liu, Qianqi; Kang, Tianyi; Jiang, Shu; Huang, Siqing; He, Jiankang; Chen, Shaochen; Du, Yanan; Gou, Maling

    2016-08-01

    Tissue engineered conduits have great promise for bridging peripheral nerve defects by providing physical guiding and biological cues. A flexible method for integrating support cells into a conduit with desired architectures is wanted. Here, a 3D-printing technology is adopted to prepare a bio-conduit with designer structures for peripheral nerve regeneration. This bio-conduit is consisted of a cryopolymerized gelatin methacryloyl (cryoGelMA) gel cellularized with adipose-derived stem cells (ASCs). By modeling using 3D-printed “lock and key” moulds, the cryoGelMA gel is structured into conduits with different geometries, such as the designed multichannel or bifurcating and the personalized structures. The cryoGelMA conduit is degradable and could be completely degraded in 2-4 months in vivo. The cryoGelMA scaffold supports the attachment, proliferation and survival of the seeded ASCs, and up-regulates the expression of their neurotrophic factors mRNA in vitro. After implanted in a rat model, the bio-conduit is capable of supporting the re-innervation across a 10 mm sciatic nerve gap, with results close to that of the autografts in terms of functional and histological assessments. The study describes an indirect 3D-printing technology for fabricating cellularized designer conduits for peripheral nerve regeneration, and could lead to the development of future nerve bio-conduits for clinical use.

  20. A compact CCD-monitored atomic force microscope with optical vision and improved performances.

    Science.gov (United States)

    Mingyue, Liu; Haijun, Zhang; Dongxian, Zhang

    2013-09-01

    A novel CCD-monitored atomic force microscope (AFM) with optical vision and improved performances has been developed. Compact optical paths are specifically devised for both tip-sample microscopic monitoring and cantilever's deflection detecting with minimized volume and optimal light-amplifying ratio. The ingeniously designed AFM probe with such optical paths enables quick and safe tip-sample approaching, convenient and effective tip-sample positioning, and high quality image scanning. An image stitching method is also developed to build a wider-range AFM image under monitoring. Experiments show that this AFM system can offer real-time optical vision for tip-sample monitoring with wide visual field and/or high lateral optical resolution by simply switching the objective; meanwhile, it has the elegant performances of nanometer resolution, high stability, and high scan speed. Furthermore, it is capable of conducting wider-range image measurement while keeping nanometer resolution. Copyright © 2013 Wiley Periodicals, Inc.

  1. Colour, vision and ergonomics.

    Science.gov (United States)

    Pinheiro, Cristina; da Silva, Fernando Moreira

    2012-01-01

    This paper is based on a research project - Visual Communication and Inclusive Design-Colour, Legibility and Aged Vision, developed at the Faculty of Architecture of Lisbon. The research has the aim of determining specific design principles to be applied to visual communication design (printed) objects, in order to be easily read and perceived by all. This study target group was composed by a selection of socially active individuals, between 55 and 80 years, and we used cultural events posters as objects of study and observation. The main objective is to overlap the study of areas such as colour, vision, older people's colour vision, ergonomics, chromatic contrasts, typography and legibility. In the end we will produce a manual with guidelines and information to apply scientific knowledge into the communication design projectual practice. Within the normal aging process, visual functions gradually decline; the quality of vision worsens, colour vision and contrast sensitivity are also affected. As people's needs change along with age, design should help people and communities, and improve life quality in the present. Applying principles of visually accessible design and ergonomics, the printed design objects, (or interior spaces, urban environments, products, signage and all kinds of visually information) will be effective, easier on everyone's eyes not only for visually impaired people but also for all of us as we age.

  2. Reinforcement learning in computer vision

    Science.gov (United States)

    Bernstein, A. V.; Burnaev, E. V.

    2018-04-01

    Nowadays, machine learning has become one of the basic technologies used in solving various computer vision tasks such as feature detection, image segmentation, object recognition and tracking. In many applications, various complex systems such as robots are equipped with visual sensors from which they learn state of surrounding environment by solving corresponding computer vision tasks. Solutions of these tasks are used for making decisions about possible future actions. It is not surprising that when solving computer vision tasks we should take into account special aspects of their subsequent application in model-based predictive control. Reinforcement learning is one of modern machine learning technologies in which learning is carried out through interaction with the environment. In recent years, Reinforcement learning has been used both for solving such applied tasks as processing and analysis of visual information, and for solving specific computer vision problems such as filtering, extracting image features, localizing objects in scenes, and many others. The paper describes shortly the Reinforcement learning technology and its use for solving computer vision problems.

  3. Tumors of peripheral nerves

    International Nuclear Information System (INIS)

    Ho, Michael; Lutz, Amelie M.

    2017-01-01

    Differentiation between malignant and benign tumors of peripheral nerves in the early stages is challenging; however, due to the unfavorable prognosis of malignant tumors early identification is required. To show the possibilities for detection, differential diagnosis and clinical management of peripheral nerve tumors by imaging appearance in magnetic resonance (MR) neurography. Review of current literature available in PubMed and MEDLINE, supplemented by the authors' own observations in clinical practice. Although not pathognomonic, several imaging features have been reported for a differentiation between distinct peripheral nerve tumors. The use of MR neurography enables detection and initial differential diagnosis in tumors of peripheral nerves. Furthermore, it plays an important role in clinical follow-up, targeted biopsy and surgical planning. (orig.) [de

  4. INL Vision and Strategy 2015

    International Nuclear Information System (INIS)

    Pillai, Rekha Sukamar

    2015-01-01

    This Laboratory vision and strategy presents INL's vision and strategy for the Laboratory and is our introduction to a special place dedicated to improving our nation's energy security future.

  5. Peripheral dentinogenic ghost cell tumor

    Directory of Open Access Journals (Sweden)

    Sushant S Kamat

    2013-01-01

    Full Text Available Dentinogenic ghost cell tumors (DGCT are uncommon lesions mainly with rare peripheral types. This report presents a case of peripheral DGCT on the left side of the mandibular alveolar ridge of a heavy smoker, a 68-year-old man, with main presenting feature as a mild pain. Submandibular lymphadenopathy and radiological "saucerization" were evident. Differential diagnosis included fibroma, neurofibroma, peripheral ameloblastoma, peripheral odontogenic fibroma, and peripheral giant cell granuloma. Histologically, ameloblastoma-like epithelial elements were seen in association with grouped ghost cells. Proliferating polyhedral cells and stellate reticulum-like cells with various densities were spread over a wide range of the field. The lesion was curetted and after 2 years of follow up, it did not recur.

  6. National Hydrogen Vision Meeting Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    None

    2001-11-01

    This document provides presentations and summaries of the notes from the National Hydrogen Vision Meeting''s facilitated breakout sessions. The Vision Meeting, which took place November 15-16, 2001, kicked off the public-private partnership that will pave the way to a more secure and cleaner energy future for America. These proceedings were compiled into a formal report, A National Vision of America''s Transition to a Hydrogen Economy - To 2030 and Beyond, which is also available online.

  7. Enhanced peripheral visual processing in congenitally deaf humans is supported by multiple brain regions, including primary auditory cortex

    Directory of Open Access Journals (Sweden)

    Gregory D. Scott

    2014-03-01

    Full Text Available Brain reorganization associated with altered sensory experience clarifies the critical role of neuroplasticity in development. An example is enhanced peripheral visual processing associated with congenital deafness, but the neural systems supporting this have not been fully characterized. A gap in our understanding of deafness-enhanced peripheral vision is the contribution of primary auditory cortex. Previous studies of auditory cortex that use anatomical normalization across participants were limited by inter-subject variability of Heschl’s gyrus. In addition to reorganized auditory cortex (cross-modal plasticity, a second gap in our understanding is the contribution of altered modality-specific cortices (visual intramodal plasticity in this case, as well as supramodal and multisensory cortices, especially when target detection is required across contrasts. Here we address these gaps by comparing fMRI signal change for peripheral versus perifoveal visual stimulation (11-15° vs. 2°-7° in congenitally deaf and hearing participants in a blocked experimental design with two analytical approaches: a Heschl’s gyrus region of interest analysis and a whole brain analysis. Our results using individually-defined primary auditory cortex (Heschl’s gyrus indicate that fMRI signal change for more peripheral stimuli was greater than perifoveal in deaf but not in hearing participants. Whole-brain analyses revealed differences between deaf and hearing participants for peripheral versus perifoveal visual processing in extrastriate visual cortex including primary auditory cortex, MT+/V5, superior-temporal auditory and multisensory and/or supramodal regions, such as posterior parietal cortex, frontal eye fields, anterior cingulate, and supplementary eye fields. Overall, these data demonstrate the contribution of neuroplasticity in multiple systems including primary auditory cortex, supramodal and multisensory regions, to altered visual processing in

  8. What is the role of community capabilities for maternal health? An exploration of community capabilities as determinants to institutional deliveries in Bangladesh, India, and Uganda

    Directory of Open Access Journals (Sweden)

    Ligia Paina

    2016-11-01

    taken into account when designing programs and interventions to support institutional deliveries. Consideration of individual factors and the capabilities of the communities in which people live would contribute to the vision of supporting people-centered approaches to health.

  9. The Vision Thing in Higher Education.

    Science.gov (United States)

    Keller, George

    1995-01-01

    It is argued that while the concept of "vision" in higher education has been met with disdain, criticism is based on misconceptions of vision's nature and role--that vision requires a charismatic administrator and that visionaries are dreamers. Educators and planners are urged to use imaginative thinking to connect the institution's and staff's…

  10. ABCs of foveal vision

    Science.gov (United States)

    Matchko, Roy M.; Gerhart, Grant R.

    2001-12-01

    This paper presents a simple mathematical performance model of the human foveal vision system based on an extensive analysis of the Blackwell-McCready (BM) data set. It includes a closed-form equation, the (ABC)t law, that allows the analyst to predict the entire range of BM threshold data. Relationships are derived among the four fundamental parameters of foveal vision: target area A, background luminance B, threshold contrast C, and stimulus presentation time t. Hyperbolic-curve fits on log-log plots of the data lead to the well-known laws of Ricco, Blackwell, Weber and Fechner, and Bloch. This paper unifies important relationships associated with target and background scene parameters as they relate to the human foveal vision process. The process of detecting a BM target, using foveal vision, is reduced to the total temporal summation of light energy modified by a multiplicative energy ratio. A stochastic model of human observer performance is presented in terms of a cumulative Gaussian distribution, which is a function of the apparent and BM contrast threshold values.

  11. Multi-spectrum-based enhanced synthetic vision system for aircraft DVE operations

    Science.gov (United States)

    Kashyap, Sudesh K.; Naidu, V. P. S.; Shanthakumar, N.

    2016-04-01

    This paper focus on R&D being carried out at CSIR-NAL on Enhanced Synthetic Vision System (ESVS) for Indian regional transport aircraft to enhance all weather operational capabilities with safety and pilot Situation Awareness (SA) improvements. Flight simulator has been developed to study ESVS related technologies and to develop ESVS operational concepts for all weather approach and landing and to provide quantitative and qualitative information that could be used to develop criteria for all-weather approach and landing at regional airports in India. Enhanced Vision System (EVS) hardware prototype with long wave Infrared sensor and low light CMOS camera is used to carry out few field trials on ground vehicle at airport runway at different visibility conditions. Data acquisition and playback system has been developed to capture EVS sensor data (image) in time synch with test vehicle inertial navigation data during EVS field experiments and to playback the experimental data on ESVS flight simulator for ESVS research and concept studies. Efforts are on to conduct EVS flight experiments on CSIR-NAL research aircraft HANSA in Degraded Visual Environment (DVE).

  12. What is vision Hampton Roads?

    Science.gov (United States)

    2010-01-01

    What is Vision Hampton Roads? : Vision Hampton Roads is... : A regionwide economic development strategy based on the collective strengths of all : localities of Hampton Roads, created with the input of business, academia, nonprofits, : government,...

  13. Fuzzy classification for strawberry diseases-infection using machine vision and soft-computing techniques

    Science.gov (United States)

    Altıparmak, Hamit; Al Shahadat, Mohamad; Kiani, Ehsan; Dimililer, Kamil

    2018-04-01

    Robotic agriculture requires smart and doable techniques to substitute the human intelligence with machine intelligence. Strawberry is one of the important Mediterranean product and its productivity enhancement requires modern and machine-based methods. Whereas a human identifies the disease infected leaves by his eye, the machine should also be capable of vision-based disease identification. The objective of this paper is to practically verify the applicability of a new computer-vision method for discrimination between the healthy and disease infected strawberry leaves which does not require neural network or time consuming trainings. The proposed method was tested under outdoor lighting condition using a regular DLSR camera without any particular lens. Since the type and infection degree of disease is approximated a human brain a fuzzy decision maker classifies the leaves over the images captured on-site having the same properties of human vision. Optimizing the fuzzy parameters for a typical strawberry production area at a summer mid-day in Cyprus produced 96% accuracy for segmented iron deficiency and 93% accuracy for segmented using a typical human instant classification approximation as the benchmark holding higher accuracy than a human eye identifier. The fuzzy-base classifier provides approximate result for decision making on the leaf status as if it is healthy or not.

  14. Temporary effects of alcohol on color vision

    Science.gov (United States)

    Geniusz, Maciej K.; Geniusz, Malwina; Szmigiel, Marta; Przeździecka-Dołyk, Joanna

    2017-09-01

    The color vision has been described as one to be very sensitive to the intake of several chemicals. The present research reviews the published literature that is concerned with color vision impairment due to alcohol. Most of this research considers people under long-term effects of alcohol. However, there is little information about temporary effects of alcohol on color vision. A group of ten volunteers aged 18-40 was studied. During the study levels of alcohol in the body were tested with a standard breathalyzer while color vision were studied using Farnsworth Munsell 100 Hue Color Vision Tests. Keywords: Col

  15. Origins of strabismus and loss of binocular vision

    Science.gov (United States)

    Bui Quoc, Emmanuel; Milleret, Chantal

    2014-01-01

    Strabismus is a frequent ocular disorder that develops early in life in humans. As a general rule, it is characterized by a misalignment of the visual axes which most often appears during the critical period of visual development. However other characteristics of strabismus may vary greatly among subjects, for example, being convergent or divergent, horizontal or vertical, with variable angles of deviation. Binocular vision may also vary greatly. Our main goal here is to develop the idea that such “polymorphy” reflects a wide variety in the possible origins of strabismus. We propose that strabismus must be considered as possibly resulting from abnormal genetic and/or acquired factors, anatomical and/or functional abnormalities, in the sensory and/or the motor systems, both peripherally and/or in the brain itself. We shall particularly develop the possible “central” origins of strabismus. Indeed, we are convinced that it is time now to open this “black box” in order to move forward. All of this will be developed on the basis of both presently available data in literature (including most recent data) and our own experience. Both data in biology and medicine will be referred to. Our conclusions will hopefully help ophthalmologists to better understand strabismus and to develop new therapeutic strategies in the future. Presently, physicians eliminate or limit the negative effects of such pathology both on the development of the visual system and visual perception through the use of optical correction and, in some cases, extraocular muscle surgery. To better circumscribe the problem of the origins of strabismus, including at a cerebral level, may improve its management, in particular with respect to binocular vision, through innovating tools by treating the pathology at the source. PMID:25309358

  16. Embedding visual routines in AnaFocus' Eye-RIS Vision Systems for closing the perception to action loop in roving robots

    Science.gov (United States)

    Jiménez-Marrufo, A.; Caballero-García, D. J.

    2011-05-01

    The purpose of the current paper is to describe how different visual routines can be developed and embedded in the AnaFocus' Eye-RIS Vision System on Chip (VSoC) to close the perception to action loop within the roving robots developed under the framework of SPARK II European project. The Eye-RIS Vision System on Chip employs a bio-inspired architecture where image acquisition and processing are truly intermingled and the processing itself is carried out in two steps. At the first step, processing is fully parallel owing to the concourse of dedicated circuit structures which are integrated close to the sensors. At the second step, processing is realized on digitally-coded information data by means of digital processors. All these capabilities make the Eye-RIS VSoC very suitable for the integration within small robots in general, and within the robots developed by the SPARK II project in particular. These systems provide with image-processing capabilities and speed comparable to high-end conventional vision systems without the need for high-density image memory and intensive digital processing. As far as perception is concerned, current perceptual schemes are often based on information derived from visual routines. Since real world images are quite complex to be processed for perceptual needs with traditional approaches, more computationally feasible algorithms are required to extract the desired features from the scene in real time, to efficiently proceed with the consequent action. In this paper the development of such algorithms and their implementation taking full advantage of the sensing-processing capabilities of the Eye-RIS VSoC are described.

  17. Interoperability Strategic Vision

    Energy Technology Data Exchange (ETDEWEB)

    Widergren, Steven E.; Knight, Mark R.; Melton, Ronald B.; Narang, David; Martin, Maurice; Nordman, Bruce; Khandekar, Aditya; Hardy, Keith S.

    2018-02-28

    The Interoperability Strategic Vision whitepaper aims to promote a common understanding of the meaning and characteristics of interoperability and to provide a strategy to advance the state of interoperability as applied to integration challenges facing grid modernization. This includes addressing the quality of integrating devices and systems and the discipline to improve the process of successfully integrating these components as business models and information technology improve over time. The strategic vision for interoperability described in this document applies throughout the electric energy generation, delivery, and end-use supply chain. Its scope includes interactive technologies and business processes from bulk energy levels to lower voltage level equipment and the millions of appliances that are becoming equipped with processing power and communication interfaces. A transformational aspect of a vision for interoperability in the future electric system is the coordinated operation of intelligent devices and systems at the edges of grid infrastructure. This challenge offers an example for addressing interoperability concerns throughout the electric system.

  18. Vision-based measuring system for rider's pose estimation during motorcycle riding

    Science.gov (United States)

    Cheli, F.; Mazzoleni, P.; Pezzola, M.; Ruspini, E.; Zappa, E.

    2013-07-01

    Inertial characteristics of the human body are comparable with the vehicle ones in motorbike riding: the study of a rider's dynamic is a crucial step in system modeling. An innovative vision based system able to measure the six degrees of freedom of the driver with respect to the vehicle is proposed here: the core of the proposed approach is an image acquisition and processing technique capable of reconstructing the position and orientation of a target fixed on the rider's back. The technique is firstly validated in laboratory tests comparing measured and imposed target motion laws and successively tested in a real case scenario during track tests with amateur and professional drivers. The presented results show the capability of the technique to correctly describe the driver's dynamic, his interaction with the vehicle as well as the possibility to use the new measuring technique in the comparison of different driving styles.

  19. Pleiades Visions

    Science.gov (United States)

    Whitehouse, M.

    2016-01-01

    Pleiades Visions (2012) is my new musical composition for organ that takes inspiration from traditional lore and music associated with the Pleiades (Seven Sisters) star cluster from Australian Aboriginal, Native American, and Native Hawaiian cultures. It is based on my doctoral dissertation research incorporating techniques from the fields of ethnomusicology and cultural astronomy; this research likely represents a new area of inquiry for both fields. This large-scale work employs the organ's vast sonic resources to evoke the majesty of the night sky and the expansive landscapes of the homelands of the above-mentioned peoples. Other important themes in Pleiades Visions are those of place, origins, cosmology, and the creation of the world.

  20. School Vision of Learning: Urban Setting

    Science.gov (United States)

    Guy, Tiffany A.

    2010-01-01

    In this paper, the author develops her school vision of learning. She explains the theories she used to help develop the vision. The author then goes into detail on the methods she will use to make her vision for a school that prepares urban students for a successful life after high school. She takes into account all the stakeholders and how they…

  1. Computer vision for an autonomous mobile robot

    CSIR Research Space (South Africa)

    Withey, Daniel J

    2015-10-01

    Full Text Available Computer vision systems are essential for practical, autonomous, mobile robots – machines that employ artificial intelligence and control their own motion within an environment. As with biological systems, computer vision systems include the vision...

  2. Altered vision destabilizes gait in older persons.

    Science.gov (United States)

    Helbostad, Jorunn L; Vereijken, Beatrix; Hesseberg, Karin; Sletvold, Olav

    2009-08-01

    This study assessed the effects of dim light and four experimentally induced changes in vision on gait speed and footfall and trunk parameters in older persons walking on level ground. Using a quasi-experimental design, gait characteristics were assessed in full light, dim light, and in dim light combined with manipulations resulting in reduced depth vision, double vision, blurred vision, and tunnel vision, respectively. A convenience sample of 24 home-dwelling older women and men (mean age 78.5 years, SD 3.4) with normal vision for their age and able to walk at least 10 m without assistance participated. Outcome measures were gait speed and spatial and temporal parameters of footfall and trunk acceleration, derived from an electronic gait mat and accelerometers. Dim light alone had no effect. Vision manipulations combined with dim light had effect on most footfall parameters but few trunk parameters. The largest effects were found regarding double and tunnel vision. Men increased and women decreased gait speed following manipulations (p=0.017), with gender differences also in stride velocity variability (p=0.017) and inter-stride medio-lateral trunk acceleration variability (p=0.014). Gender effects were related to differences in body height and physical functioning. Results indicate that visual problems lead to a more cautious and unstable gait pattern even under relatively simple conditions. This points to the importance of assessing vision in older persons and correcting visual impairments where possible.

  3. Will Brazilian Patented Naturoptic Method for Recovery of Healthy Vision be Helpful Linguistically?

    Science.gov (United States)

    de Moraes, Ana Paula; Dos Santos Marques, Rosélia; Mc Leod, Roger David

    2008-10-01

    Naturoptics Inc. extends its patent(s) to further the teaching of vision-restoring process(es), foster cross-linguistic capabilities, and assist in the educational or financial opportunities of individuals and countries. Directors of Naturoptics Inc. hope to achieve this while testing David Matthew Mc Leod's observations that high visual acuity correlates with other mental and sensory processes. He and RDM often noticed that thought concepts (language percepts) are detectable even across species barriers, as when bears, moose, et c. made their intentions known to us in ways we were culturally willing to accept. This addresses aspects of language that seemed related to our understanding of human vision, and how it encodes cortically by spatial frequency content of a visual scene. Words representing the same meaning in two different languages will encode at precisely the same site in the visual cortex. Predictions: ``our memories,'' and cross-species, detection of certain thoughts, if equivalently ``seen'' as images, (spatial frequency content).

  4. Vision Restoration in Glaucoma by Activating Residual Vision with a Holistic, Clinical Approach: A Review.

    Science.gov (United States)

    Sabel, Bernhard A; Cárdenas-Morales, Lizbeth; Gao, Ying

    2018-01-01

    How to cite this article: Sabel BA, Cárdenas-Morales L, Gao Y. Vision Restoration in Glaucoma by activating Residual Vision with a Holistic, Clinical Approach: A Review. J Curr Glaucoma Pract 2018;12(1):1-9.

  5. Accuracy of vision technicians in screening ocular pathology at rural vision centres of southern India.

    Science.gov (United States)

    Suram, Vasantha; Addepalli, Uday Kumar; Krishnaiah, Sannapaneni; Kovai, Vilas; Khanna, Rohit C

    2016-03-01

    There is paucity of data on the inter-observer agreement and diagnostic accuracy between a primary-care technician (vision technician) and an ophthalmologist. Hence, the current study was conducted to assess the accuracy of vision technicians, to screen potentially sight-threatening ocular conditions at rural vision centres of southern India and their agreement with an ophthalmologist. In July to August 2010, patients presenting to seven vision centres in Adilabad district (Andhra Pradesh) were selected and screened in a masked manner by seven vision technicians followed by an examination by a consultant ophthalmologist. Agreement was assessed between vision technicians and the ophthalmologist for screening of potential sight-threatening ocular conditions and decisions for referral. The ophthalmologist's findings were considered as the reference standard. Two hundred and seventy-nine patients were enrolled at seven vision centres with a mean age of 32.9 ± 21.8 years. Agreement for screening of ocular pathology was 0.82 (95 per cent CI, 0.8-0.83). There was excellent agreement for cataract (0.97; 95 per cent CI, 0.93-1), refractive error (0.98; 95 per cent CI, 0.96-1), corneal pathology (1.0; 95 per cent CI, 1.0-1.0) and other anterior segment pathology (0.95; 95 per cent CI, 0.9-1); the agreement was moderate to fair for detection of glaucoma suspects (0.43; 95 per cent CI, 0.28-0.60) and retinal pathology (0.39; 95 per cent CI, 0.14-0.63). Sensitivity for screening of anterior segment pathology was 94.6-100 per cent. There was a fair to moderate sensitivity for glaucoma suspect; 35.6 per cent (95 per cent CI, 21.9-51.2) and retinal pathology 26.3 per cent (95 per cent CI, 9.2-51.2). Specificity for screening of ocular pathology was 98.2 to 100 per cent. The kappa (κ) agreement for referral for any pathology was 0.82 (0.8-0.83) CONCLUSION: As there is good agreement between the vision technicians and the ophthalmologist for screening and referral of

  6. Simple laser vision sensor calibration for surface profiling applications

    Science.gov (United States)

    Abu-Nabah, Bassam A.; ElSoussi, Adnane O.; Al Alami, Abed ElRahman K.

    2016-09-01

    Due to the relatively large structures in the Oil and Gas industry, original equipment manufacturers (OEMs) have been implementing custom-designed laser vision sensor (LVS) surface profiling systems as part of quality control in their manufacturing processes. The rough manufacturing environment and the continuous movement and misalignment of these custom-designed tools adversely affect the accuracy of laser-based vision surface profiling applications. Accordingly, Oil and Gas businesses have been raising the demand from the OEMs to implement practical and robust LVS calibration techniques prior to running any visual inspections. This effort introduces an LVS calibration technique representing a simplified version of two known calibration techniques, which are commonly implemented to obtain a calibrated LVS system for surface profiling applications. Both calibration techniques are implemented virtually and experimentally to scan simulated and three-dimensional (3D) printed features of known profiles, respectively. Scanned data is transformed from the camera frame to points in the world coordinate system and compared with the input profiles to validate the introduced calibration technique capability against the more complex approach and preliminarily assess the measurement technique for weld profiling applications. Moreover, the sensitivity to stand-off distances is analyzed to illustrate the practicality of the presented technique.

  7. Soft Computing Techniques in Vision Science

    CERN Document Server

    Yang, Yeon-Mo

    2012-01-01

    This Special Edited Volume is a unique approach towards Computational solution for the upcoming field of study called Vision Science. From a scientific firmament Optics, Ophthalmology, and Optical Science has surpassed an Odyssey of optimizing configurations of Optical systems, Surveillance Cameras and other Nano optical devices with the metaphor of Nano Science and Technology. Still these systems are falling short of its computational aspect to achieve the pinnacle of human vision system. In this edited volume much attention has been given to address the coupling issues Computational Science and Vision Studies.  It is a comprehensive collection of research works addressing various related areas of Vision Science like Visual Perception and Visual system, Cognitive Psychology, Neuroscience, Psychophysics and Ophthalmology, linguistic relativity, color vision etc. This issue carries some latest developments in the form of research articles and presentations. The volume is rich of contents with technical tools ...

  8. Dense image correspondences for computer vision

    CERN Document Server

    Liu, Ce

    2016-01-01

    This book describes the fundamental building-block of many new computer vision systems: dense and robust correspondence estimation. Dense correspondence estimation techniques are now successfully being used to solve a wide range of computer vision problems, very different from the traditional applications such techniques were originally developed to solve. This book introduces the techniques used for establishing correspondences between challenging image pairs, the novel features used to make these techniques robust, and the many problems dense correspondences are now being used to solve. The book provides information to anyone attempting to utilize dense correspondences in order to solve new or existing computer vision problems. The editors describe how to solve many computer vision problems by using dense correspondence estimation. Finally, it surveys resources, code, and data necessary for expediting the development of effective correspondence-based computer vision systems.   ·         Provides i...

  9. Hepatic abscess versus peripheral cholangiocarcinoma: Sonographic differentiation

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hwan Hoon; Kim, Yun Hwan; Kang, Chang Ho; Chung, Kyoo Byung; Suh, Won Hyuck [Korea University College of Medicine, Seoul (Korea, Republic of); Lee, Chang Hee [Kunkuk University College of Medicine, Chung-Ju Hospital, Chung-Ju (Korea, Republic of)

    2000-12-15

    To find out the sonographic findings that are useful to differentiate hepatic abscess from peripheral cholangiocarcinoma. Twenty-two hepatic abscesses and 22 peripheral cholangiocarcinomas which had been confirmed histologically were included in this study. Objective points were echo characteristics of the lesion, internal septation, presence of peripheral low echoic rim, demarcation from normal liver(well or poorly defined), posterior enhancement, multiplicity, dilatation of bile duct(obstructive or non-obstructive), intrahepatic duct stone, pleural effusion, and intra-abdominal fluid collection. Echo characteristics of the lesion were classified in-to four types. Type I; Predominantly echogenic with hypoechoic portion, type II; Echogenic without hypoechoic portion, type III; Predominantly hypoechoic with echogenic portion, type IV; Hypoechoic without echogenic portion. 1)Nine abscesses and 2 peripheral cholangiocarcinomas were type I(p=0.037), 2)One abscess and 18 peripheral cholangiocarcinomas were type II(p=0.001), 3)Seven abscesses and none of peripheral cholangiocarcinomas were type III(p=0.001), 4)Five abscesses and 2 peripheral cholangiocarcinomas were type IV(p=0.410). Only 7 abscesses showed internal septations(p=0.013). One abscess and 9 peripheral cholangiocarcinomas showed peripheral hypoechoic halos(p=0.012). Only 9 peripheral cholangiocarcinomas showed obstructive bile duct dilatation (p=0.001). There were no statistically significant differences between abscess and peripheral cholangiocarcinoma on other objective points. Predominantly echogenic with hypoechoic portion, predominantly hypoechoic with echogenic portion, and internal septation are the features suggestive of hepatic abscess, and echogenic without hypoechoic portion, peripheral hypoechoic halo, obstructive bile duct dilatation are suggestive of peripheral cholangiocarcinoma. Therefore these sonographic findings are helpful to differentiate hepatic abscess from peripheral

  10. Participative Action Research: The Vision Conference

    Directory of Open Access Journals (Sweden)

    René Victor Valqui Vidal

    2003-11-01

    Full Text Available This paper presents the principles behind the design and management of the Vision Conference: a one-day workshop for a large group of participants endeavoured to create ideas, projects and visions for the future activities of a local community or an organisation. A case study from a local community in Denmark is also presented with the purpose of illustrating the organisation, planning and management of a Vision Conference. The paper focuses in the three central social processes of the conference: group work, problem solving and facilitation. The paper ends with a discussion of creativity and creativity techniques suitable for Vision Conferences.

  11. Regional new energy vision for Fukuoka city; Fukuokashi chiiki shin energy vision

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-02-01

    A regional new energy vision has been formulated for Fukuoka city, Fukuoka Prefecture, which will serve as a basic guide to the promotion of new energy introduction which is one of the measures for coping with environmental problems. The vision is described in five chapters of (1) the local characteristics of Fukuoka city, (2) energy situation in Fukuoka city, (3) basic program, (4) high priority plans, and (5) efforts to enhance the vision toward realization. Discussed as high priority plans are the introduction of new energy into public buildings above all others, high efficiency utilization of refuse-derived energy, utilization of new energy at water supply and drainage facilities, utilization of water temperature difference energy, introduction of clean energy vehicles, promotion of a new energy industry, and the extension of assistance for encouraging citizens and industrialists to adopt new energy. In extending assistance for encouraging the introduction of new energy, studies are made about measures for introducing new energy into individual residences and about a citizenry-involving new energy adopting industry (offering a site to the power generation industry) under the basal conditions that information be supplied sufficiently and that the citizenry and administration cooperate with each other in driving forward the vision. (NEDO)

  12. The Uniformity Illusion

    NARCIS (Netherlands)

    Otten, Marte; Pinto, Yair; Paffen, C.L.E.; Seth, Anil; Kanai, Ryota

    2017-01-01

    Vision in the fovea, the center of the visual field, is much more accurate and detailed than vision in the periphery. This is not in line with the rich phenomenology of peripheral vision. Here, we investigated a visual illusion that shows that detailed peripheral visual experience is partially based

  13. Data Fusion for a Vision-Radiological System for Source Tracking and Discovery

    Energy Technology Data Exchange (ETDEWEB)

    Enqvist, Andreas; Koppal, Sanjeev [University of Florida, Gainesville, FL, 32606 (United States)

    2015-07-01

    A multidisciplinary approach to allow the tracking of the movement of radioactive sources by fusing data from multiple radiological and visual sensors is under development. The goal is to improve the ability to detect, locate, track and identify nuclear/radiological threats. The key concept is that such widely available visual and depth sensors can impact radiological detection, since the intensity fall-off in the count rate can be correlated to movement in three dimensions. To enable this, we pose an important question; what is the right combination of sensing modalities and vision algorithms that can best compliment a radiological sensor, for the purpose of detection and tracking of radioactive material? Similarly what is the best radiation detection methods and unfolding algorithms suited for data fusion with tracking data? Data fusion of multi-sensor data for radiation detection have seen some interesting developments lately. Significant examples include intelligent radiation sensor systems (IRSS), which are based on larger numbers of distributed similar or identical radiation sensors coupled with position data for network capable to detect and locate radiation source. Other developments are gamma-ray imaging systems based on Compton scatter in segmented detector arrays. Similar developments using coded apertures or scatter cameras for neutrons have recently occurred. The main limitation of such systems is not so much in their capability but rather in their complexity and cost which is prohibitive for large scale deployment. Presented here is a fusion system based on simple, low-cost computer vision and radiological sensors for tracking of multiple objects and identifying potential radiological materials being transported or shipped. The main focus of this work is the development on two separate calibration algorithms for characterizing the fused sensor system. The deviation from a simple inverse square-root fall-off of radiation intensity is explored and

  14. Data Fusion for a Vision-Radiological System for Source Tracking and Discovery

    International Nuclear Information System (INIS)

    Enqvist, Andreas; Koppal, Sanjeev

    2015-01-01

    A multidisciplinary approach to allow the tracking of the movement of radioactive sources by fusing data from multiple radiological and visual sensors is under development. The goal is to improve the ability to detect, locate, track and identify nuclear/radiological threats. The key concept is that such widely available visual and depth sensors can impact radiological detection, since the intensity fall-off in the count rate can be correlated to movement in three dimensions. To enable this, we pose an important question; what is the right combination of sensing modalities and vision algorithms that can best compliment a radiological sensor, for the purpose of detection and tracking of radioactive material? Similarly what is the best radiation detection methods and unfolding algorithms suited for data fusion with tracking data? Data fusion of multi-sensor data for radiation detection have seen some interesting developments lately. Significant examples include intelligent radiation sensor systems (IRSS), which are based on larger numbers of distributed similar or identical radiation sensors coupled with position data for network capable to detect and locate radiation source. Other developments are gamma-ray imaging systems based on Compton scatter in segmented detector arrays. Similar developments using coded apertures or scatter cameras for neutrons have recently occurred. The main limitation of such systems is not so much in their capability but rather in their complexity and cost which is prohibitive for large scale deployment. Presented here is a fusion system based on simple, low-cost computer vision and radiological sensors for tracking of multiple objects and identifying potential radiological materials being transported or shipped. The main focus of this work is the development on two separate calibration algorithms for characterizing the fused sensor system. The deviation from a simple inverse square-root fall-off of radiation intensity is explored and

  15. Determining the Status of Organizational Agility Capabilities in complementary and convertor Agricultural Industries using the Fuzzy Approach

    Directory of Open Access Journals (Sweden)

    2014-03-01

    Full Text Available Manufacturing industries of agricultural products, which constitute a considerable part of different countries’ economies, are seeking new profitable opportunities by increasing competition at the international level. Organizational agility is new method and philosophy of production that seeks to react effectively to the variable and unpredictable environment and to utilize the changes as chances for organizational progress and profitability. In this regard, the present research aims to survey the capabilities of organizational agility in complementary and convertor agricultural industries. For this purpose, based on organizational agility literature, four variables- responsiveness, competency, flexibility, and quickness- were examined as the agility capabilities. The research method was descriptive, and the statistical population included 142 managers of Agricultural industries in East Azarbaijan Province during the year 2012. The study sample was calculated 117 using simple random sampling technique. For data collection, the questionnaire was designed by some scholars. The data was analyzed by means of descriptive statistics, inferential statistics and fuzzy set theory. The results showed that the complementary and the convertor agricultural industries of the province have obtained scores higher than the average for the capabilities of responsiveness, flexibility, and quickness but a lower one for the capability of the competency. With regard to the fact that compiling the strategic vision, technological ability, and introducing the new products are among the main components of achieving competency, it is suggested that managers of this sector should, in order to reinforce competency in agricultural industries, pay special attention to compiling the strategic vision, making use of information technology, and using the new opportunities of the market to introduce the new products.

  16. VISION User Guide - VISION (Verifiable Fuel Cycle Simulation) Model

    International Nuclear Information System (INIS)

    Jacobson, Jacob J.; Jeffers, Robert F.; Matthern, Gretchen E.; Piet, Steven J.; Baker, Benjamin A.; Grimm, Joseph

    2009-01-01

    The purpose of this document is to provide a guide for using the current version of the Verifiable Fuel Cycle Simulation (VISION) model. This is a complex model with many parameters; the user is strongly encouraged to read this user guide before attempting to run the model. This model is an R and D work in progress and may contain errors and omissions. It is based upon numerous assumptions. This model is intended to assist in evaluating 'what if' scenarios and in comparing fuel, reactor, and fuel processing alternatives at a systems level for U.S. nuclear power. The model is not intended as a tool for process flow and design modeling of specific facilities nor for tracking individual units of fuel or other material through the system. The model is intended to examine the interactions among the components of a fuel system as a function of time varying system parameters; this model represents a dynamic rather than steady-state approximation of the nuclear fuel system. VISION models the nuclear cycle at the system level, not individual facilities, e.g., 'reactor types' not individual reactors and 'separation types' not individual separation plants. Natural uranium can be enriched, which produces enriched uranium, which goes into fuel fabrication, and depleted uranium (DU), which goes into storage. Fuel is transformed (transmuted) in reactors and then goes into a storage buffer. Used fuel can be pulled from storage into either separation of disposal. If sent to separations, fuel is transformed (partitioned) into fuel products, recovered uranium, and various categories of waste. Recycled material is stored until used by its assigned reactor type. Note that recovered uranium is itself often partitioned: some RU flows with recycled transuranic elements, some flows with wastes, and the rest is designated RU. RU comes out of storage if needed to correct the U/TRU ratio in new recycled fuel. Neither RU nor DU are designated as wastes. VISION is comprised of several Microsoft

  17. delta-vision

    Data.gov (United States)

    California Natural Resource Agency — Delta Vision is intended to identify a strategy for managing the Sacramento-San Joaquin Delta as a sustainable ecosystem that would continue to support environmental...

  18. Airborne Use of Night Vision Systems

    Science.gov (United States)

    Mepham, S.

    1990-04-01

    Mission Management Department of the Royal Aerospace Establishment has won a Queen's Award for Technology, jointly with GEC Sensors, in recognition of innovation and success in the development and application of night vision technology for fixed wing aircraft. This work has been carried out to satisfy the operational needs of the Royal Air Force. These are seen to be: - Operations in the NATO Central Region - To have a night as well as a day capability - To carry out low level, high speed penetration - To attack battlefield targets, especially groups of tanks - To meet these objectives at minimum cost The most effective way to penetrate enemy defences is at low level and survivability would be greatly enhanced with a first pass attack. It is therefore most important that not only must the pilot be able to fly at low level to the target but also he must be able to detect it in sufficient time to complete a successful attack. An analysis of the average operating conditions in Central Europe during winter clearly shows that high speed low level attacks can only be made for about 20 per cent of the 24 hours. Extending this into good night conditions raises the figure to 60 per cent. Whilst it is true that this is for winter conditions and in summer the situation is better, the overall advantage to be gained is clear. If our aircraft do not have this capability the potential for the enemy to advance his troops and armour without hinderance for considerable periods is all too obvious. There are several solutions to providing such a capability. The one chosen for Tornado GR1 is to use Terrain Following Radar (TFR). This system is a complete 24 hour capability. However it has two main disadvantages, it is an active system which means it can be jammed or homed into, and is useful in attacking pre-planned targets. Second it is an expensive system which precludes fitting to other than a small number of aircraft.

  19. Computer and machine vision theory, algorithms, practicalities

    CERN Document Server

    Davies, E R

    2012-01-01

    Computer and Machine Vision: Theory, Algorithms, Practicalities (previously entitled Machine Vision) clearly and systematically presents the basic methodology of computer and machine vision, covering the essential elements of the theory while emphasizing algorithmic and practical design constraints. This fully revised fourth edition has brought in more of the concepts and applications of computer vision, making it a very comprehensive and up-to-date tutorial text suitable for graduate students, researchers and R&D engineers working in this vibrant subject. Key features include: Practical examples and case studies give the 'ins and outs' of developing real-world vision systems, giving engineers the realities of implementing the principles in practice New chapters containing case studies on surveillance and driver assistance systems give practical methods on these cutting-edge applications in computer vision Necessary mathematics and essential theory are made approachable by careful explanations and well-il...

  20. Standards for vision science libraries: 2014 revision.

    Science.gov (United States)

    Motte, Kristin; Caldwell, C Brooke; Lamson, Karen S; Ferimer, Suzanne; Nims, J Chris

    2014-10-01

    This Association of Vision Science Librarians revision of the "Standards for Vision Science Libraries" aspires to provide benchmarks to address the needs for the services and resources of modern vision science libraries (academic, medical or hospital, pharmaceutical, and so on), which share a core mission, are varied by type, and are located throughout the world. Through multiple meeting discussions, member surveys, and a collaborative revision process, the standards have been updated for the first time in over a decade. While the range of types of libraries supporting vision science services, education, and research is wide, all libraries, regardless of type, share core attributes, which the standards address. The current standards can and should be used to help develop new vision science libraries or to expand the growth of existing libraries, as well as to support vision science librarians in their work to better provide services and resources to their respective users.

  1. Efficacy of vision therapy in children with learning disability and associated binocular vision anomalies

    Directory of Open Access Journals (Sweden)

    Jameel Rizwana Hussaindeen

    2018-01-01

    Conclusion: Children with specific learning disorders have a high frequency of binocular vision disorders and vision therapy plays a significant role in improving the BV parameters. Children with SLD should be screened for BV anomalies as it could potentially be an added hindrance to the reading difficulty in this special population.

  2. Prevalence of computer vision syndrome in Erbil

    Directory of Open Access Journals (Sweden)

    Dler Jalal Ahmed

    2018-04-01

    Full Text Available Background and objective: Nearly all colleges, universities and homes today are regularly using video display terminals, such as computer, iPad, mobile, and TV. Very little research has been carried out on Kurdish users to reveal the effect of video display terminals on the eye and vision. This study aimed to evaluate the prevalence of computer vision syndrome among computer users. Methods: A hospital based cross-sectional study was conducted in the Ophthalmology Department of Rizgary and Erbil teaching hospitals in Erbil city. Those used computers in the months preceding the date of this study were included in the study. Results: Among 173 participants aged between 8 to 48 years (mean age of 23.28±6.6 years, the prevalence of computer vision syndrome found to be 89.65%. The most disturbing symptom was eye irritation (79.8%, followed by blurred vision(75.7%. Participants who were using visual display terminals for more than six hours per day were at higher risk of developing nearly all symptoms of computer vision syndrome. Significant correlation was found between time-consuming on computer and symptoms such as headache (P <0.001, redness (P <0.001, eye irritation (P <0.001, blurred vision (P <0.001 and neck pain (P <0.001. Conclusion: The present study demonstrates that more than three-fourths of the participants had one of the symptoms of computer vision syndrome while working on visual display terminals. Keywords: Computer vision syndrome; Headache; Neck pain; Blurred vision.

  3. Representing vision and blindness.

    Science.gov (United States)

    Ray, Patrick L; Cox, Alexander P; Jensen, Mark; Allen, Travis; Duncan, William; Diehl, Alexander D

    2016-01-01

    There have been relatively few attempts to represent vision or blindness ontologically. This is unsurprising as the related phenomena of sight and blindness are difficult to represent ontologically for a variety of reasons. Blindness has escaped ontological capture at least in part because: blindness or the employment of the term 'blindness' seems to vary from context to context, blindness can present in a myriad of types and degrees, and there is no precedent for representing complex phenomena such as blindness. We explore current attempts to represent vision or blindness, and show how these attempts fail at representing subtypes of blindness (viz., color blindness, flash blindness, and inattentional blindness). We examine the results found through a review of current attempts and identify where they have failed. By analyzing our test cases of different types of blindness along with the strengths and weaknesses of previous attempts, we have identified the general features of blindness and vision. We propose an ontological solution to represent vision and blindness, which capitalizes on resources afforded to one who utilizes the Basic Formal Ontology as an upper-level ontology. The solution we propose here involves specifying the trigger conditions of a disposition as well as the processes that realize that disposition. Once these are specified we can characterize vision as a function that is realized by certain (in this case) biological processes under a range of triggering conditions. When the range of conditions under which the processes can be realized are reduced beyond a certain threshold, we are able to say that blindness is present. We characterize vision as a function that is realized as a seeing process and blindness as a reduction in the conditions under which the sight function is realized. This solution is desirable because it leverages current features of a major upper-level ontology, accurately captures the phenomenon of blindness, and can be

  4. Hi-Vision telecine system using pickup tube

    Science.gov (United States)

    Iijima, Goro

    1992-08-01

    Hi-Vision broadcasting, offering far more lifelike pictures than those produced by existing television broadcasting systems, has enormous potential in both industrial and commercial fields. The dissemination of the Hi-Vision system will enable vivid, movie theater quality pictures to be readily enjoyed in homes in the near future. To convert motion film pictures into Hi-Vision signals, a telecine system is needed. The Hi-Vision telecine systems currently under development are the "laser telecine," "flying-spot telecine," and "Saticon telecine" systems. This paper provides an overview of the pickup tube type Hi-Vision telecine system (referred to herein as the Saticon telecine system) developed and marketed by Ikegami Tsushinki Co., Ltd.

  5. Low Vision Care: The Need to Maximise Visual Potential

    Directory of Open Access Journals (Sweden)

    Ramachandra Pararajasegaram

    2004-01-01

    Full Text Available People with low vision have residual vision with some light perception, but their vision loss does not lend itself to improvement by standard spectacles or medical or surgical treatment. Such persons have the potential for enhanced functional vision if they receive appropriate low vision care services.

  6. Algorithmic strategies for FPGA-based vision

    OpenAIRE

    Lim, Yoong Kang

    2016-01-01

    As demands for real-time computer vision applications increase, implementations on alternative architectures have been explored. These architectures include Field-Programmable Gate Arrays (FPGAs), which offer a high degree of flexibility and parallelism. A problem with this is that many computer vision algorithms have been optimized for serial processing, and this often does not map well to FPGA implementation. This thesis introduces the concept of FPGA-tailored computer vision algorithms...

  7. Eldercare at Home: Vision Problems

    Science.gov (United States)

    ... seeing close objects or reading small print. Many things can be done to help with these vision problems. Using reading ... t Working If vision problems seem to be getting worse and are of major concern to the ... what the results have been. Related Resources ...

  8. Embedded active vision system based on an FPGA architecture

    OpenAIRE

    Chalimbaud , Pierre; Berry , François

    2006-01-01

    International audience; In computer vision and more particularly in vision processing, the impressive evolution of algorithms and the emergence of new techniques dramatically increase algorithm complexity. In this paper, a novel FPGA-based architecture dedicated to active vision (and more precisely early vision) is proposed. Active vision appears as an alternative approach to deal with artificial vision problems. The central idea is to take into account the perceptual aspects of visual tasks,...

  9. Development of regenerative peripheral nerve interfaces for motor control of neuroprosthetic devices

    Science.gov (United States)

    Kemp, Stephen W. P.; Urbanchek, Melanie G.; Irwin, Zachary T.; Chestek, Cynthia A.; Cederna, Paul S.

    2017-05-01

    Traumatic peripheral nerve injuries suffered during amputation commonly results in debilitating neuropathic pain in the affected limb. Modern prosthetic technologies allow for intuitive, simultaneous control of multiple degrees of freedom. However, these state-of-the-art devices require separate, independent control signals for each degree of freedom, which is currently not possible. As a result, amputees reject up to 75% of myoelectric devices preferring instead to use body-powered artificial limbs which offer subtle sensory feedback. Without meaningful and intuitive sensory feedback, even the most advanced myoelectric prostheses remain insensate, burdensome, and are associated with enormous cognitive demand and mental fatigue. The ideal prosthetic device is one which is capable of providing intuitive somatosensory feedback essential for interaction with the environment. Critical to the design of such a bioprosthetic device is the development of a reliable biologic interface between human and machine. This ideal patient-prosthetic interface allows for transmission of both afferent somatosensory information and efferent motor signals for a closed-loop feedback system of neural control. Our lab has developed the Regenerative Peripheral Nerve Interface (RPNI) as a biologic nerve interface designed for stable integration of a prosthetic device with transected peripheral nerves in a residual limb. The RPNI is constructed by surgically implanting the distal end of a transected peripheral nerve into an autogenous muscle graft. Animal experiments in our lab have shown recording of motor signals from RPNI's implanted into both rodents and monkeys. Here, we achieve high amplitude EMG signals with a high signal to noise (SNR) ratio.

  10. A vision-based system for fast and accurate laser scanning in robot-assisted phonomicrosurgery.

    Science.gov (United States)

    Dagnino, Giulio; Mattos, Leonardo S; Caldwell, Darwin G

    2015-02-01

    Surgical quality in phonomicrosurgery can be improved by open-loop laser control (e.g., high-speed scanning capabilities) with a robust and accurate closed-loop visual servoing systems. A new vision-based system for laser scanning control during robot-assisted phonomicrosurgery was developed and tested. Laser scanning was accomplished with a dual control strategy, which adds a vision-based trajectory correction phase to a fast open-loop laser controller. The system is designed to eliminate open-loop aiming errors caused by system calibration limitations and by the unpredictable topology of real targets. Evaluation of the new system was performed using CO(2) laser cutting trials on artificial targets and ex-vivo tissue. This system produced accuracy values corresponding to pixel resolution even when smoke created by the laser-target interaction clutters the camera view. In realistic test scenarios, trajectory following RMS errors were reduced by almost 80 % with respect to open-loop system performances, reaching mean error values around 30 μ m and maximum observed errors in the order of 60 μ m. A new vision-based laser microsurgical control system was shown to be effective and promising with significant positive potential impact on the safety and quality of laser microsurgeries.

  11. Age-Related Psychophysical Changes and Low Vision

    Science.gov (United States)

    Dagnelie, Gislin

    2013-01-01

    When considering the burden of visual impairment on aging individuals and society at large, it is important to bear in mind that vision changes are a natural aspect of aging. In this article, we consider vision changes that are part of normal aging, the prevalence of abnormal vision changes caused by disorders of the visual system, and the anticipated incidence and impact of visual impairment as the US population ages. We then discuss the services available to reduce the impact of vision loss, and the extent to which those services can and should be improved, not only to be better prepared for the anticipated increase in low vision over the coming decades, but also to increase the awareness of interactions between visual impairment and comorbidities that are common among the elderly. Finally, we consider how to promote improved quality, availability, and acceptance of low vision care to lessen the impact of visual impairment on individuals, and its burden on society. PMID:24335074

  12. State of Vision Development in Slovenian Companies

    Directory of Open Access Journals (Sweden)

    Vojko Toman

    2014-05-01

    Full Text Available Vision is a prerequisite for efficient strategic planning and the effectiveness of a company. If a company has no vision (i.e., it does not know where it is heading, then it cannot build on advantages, eliminate weaknesses, exploit opportunities and avoid threats. The term ‘vision’ is often used in scientific and professional literature, but it should be noted that different authors understand the term differently and often discuss it inadequately. Many questions regarding the nature of vision arise in practice and in theory, and I answer many of them in my article. I define vision, explain the reasons for its necessity and provide its characteristics and content. I define mission and explain the main difference between vision and mission. The majority of the article presents the results of empirical research on the state of vision setting in Slovenian companies. The article highlights the way in which these terms are understood by top managers.

  13. Enhanced memory architecture for massively parallel vision chip

    Science.gov (United States)

    Chen, Zhe; Yang, Jie; Liu, Liyuan; Wu, Nanjian

    2015-04-01

    Local memory architecture plays an important role in high performance massively parallel vision chip. In this paper, we propose an enhanced memory architecture with compact circuit area designed in a full-custom flow. The memory consists of separate master-stage static latches and shared slave-stage dynamic latches. We use split transmission transistors on the input data path to enhance tolerance for charge sharing and to achieve random read/write capabilities. The memory is designed in a 0.18 μm CMOS process. The area overhead of the memory achieves 16.6 μm2/bit. Simulation results show that the maximum operating frequency reaches 410 MHz and the corresponding peak dynamic power consumption for a 64-bit memory unit is 190 μW under 1.8 V supply voltage.

  14. Understanding and applying machine vision

    CERN Document Server

    Zeuch, Nello

    2000-01-01

    A discussion of applications of machine vision technology in the semiconductor, electronic, automotive, wood, food, pharmaceutical, printing, and container industries. It describes systems that enable projects to move forward swiftly and efficiently, and focuses on the nuances of the engineering and system integration of machine vision technology.

  15. The surgery of peripheral nerves (including tumors)

    DEFF Research Database (Denmark)

    Fugleholm, Kåre

    2013-01-01

    Surgical pathology of the peripheral nervous system includes traumatic injury, entrapment syndromes, and tumors. The recent significant advances in the understanding of the pathophysiology and cellular biology of peripheral nerve degeneration and regeneration has yet to be translated into improved...... surgical techniques and better outcome after peripheral nerve injury. Decision making in peripheral nerve surgery continues to be a complex challenge, where the mechanism of injury, repeated clinical evaluation, neuroradiological and neurophysiological examination, and detailed knowledge of the peripheral...... nervous system response to injury are prerequisite to obtain the best possible outcome. Surgery continues to be the primary treatment modality for peripheral nerve tumors and advances in adjuvant oncological treatment has improved outcome after malignant peripheral nerve tumors. The present chapter...

  16. Low-Power Smart Imagers for Vision-Enabled Sensor Networks

    CERN Document Server

    Fernández-Berni, Jorge; Rodríguez-Vázquez, Ángel

    2012-01-01

    This book presents a comprehensive, systematic approach to the development of vision system architectures that employ sensory-processing concurrency and parallel processing to meet the autonomy challenges posed by a variety of safety and surveillance applications.  Coverage includes a thorough analysis of resistive diffusion networks embedded within an image sensor array. This analysis supports a systematic approach to the design of spatial image filters and their implementation as vision chips in CMOS technology. The book also addresses system-level considerations pertaining to the embedding of these vision chips into vision-enabled wireless sensor networks.  Describes a system-level approach for designing of vision devices and  embedding them into vision-enabled, wireless sensor networks; Surveys state-of-the-art, vision-enabled WSN nodes; Includes details of specifications and challenges of vision-enabled WSNs; Explains architectures for low-energy CMOS vision chips with embedded, programmable spatial f...

  17. Investigation report on establishment of new energy vision in Toyohashi area; Toyohashi chiiki shin energy vision sakutei chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-02-01

    The 'new energy vision for Toyohashi (Aichi Prefecture) area' was established from the viewpoint that proliferation of new energy use, which is less familiar and higher in cost, requires induction by urban and environmental measures, and consistency with district characteristics. The achievements were put into order as the report on the Toyohashi area new energy vision and the investigation on the vision establishment. The vision is composed by the following four items: 1) basic matters concerning the vision, 2) ideas and policies of the vision, 3) major measures for introducing new energies, and 4) promotion of the vision. Item 3) presents the introduction measures, introduction project, and measure development by areas. Considerations on the introduction measures include enlightenment for proliferation, expansion in information provision, development of preferential treatments, initiative introduction into public facilities, and the measures to strengthen cooperative works by citizens, business entities, and the administration. The following four projects were set: introduction of wastes power generation into the Resource Production Center (wastes treatment plant), improvement of the surplus heat utilization facilities, and introduction of wind power generation into the General Agricultural Park. (NEDO)

  18. Investigation report on establishment of new energy vision in Toyohashi area; Toyohashi chiiki shin energy vision sakutei chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-02-01

    The 'new energy vision for Toyohashi (Aichi Prefecture) area' was established from the viewpoint that proliferation of new energy use, which is less familiar and higher in cost, requires induction by urban and environmental measures, and consistency with district characteristics. The achievements were put into order as the report on the Toyohashi area new energy vision and the investigation on the vision establishment. The vision is composed by the following four items: 1) basic matters concerning the vision, 2) ideas and policies of the vision, 3) major measures for introducing new energies, and 4) promotion of the vision. Item 3) presents the introduction measures, introduction project, and measure development by areas. Considerations on the introduction measures include enlightenment for proliferation, expansion in information provision, development of preferential treatments, initiative introduction into public facilities, and the measures to strengthen cooperative works by citizens, business entities, and the administration. The following four projects were set: introduction of wastes power generation into the Resource Production Center (wastes treatment plant), improvement of the surplus heat utilization facilities, and introduction of wind power generation into the General Agricultural Park. (NEDO)

  19. Quantitative evaluation of vision-related and health-related quality of life after endoscopic transsphenoidal surgery for pituitary adenoma.

    Science.gov (United States)

    Wolf, Amparo; Coros, Alexandra; Bierer, Joel; Goncalves, Sandy; Cooper, Paul; Van Uum, Stan; Lee, Donald H; Proulx, Alain; Nicolle, David; Fraser, J Alexander; Rotenberg, Brian W; Duggal, Neil

    2017-08-01

    OBJECTIVE Endoscopic resection of pituitary adenomas has been reported to improve vision function in up to 80%-90% of patients with visual impairment due to these adenomas. It is unclear how these reported rates translate into improvement in visual outcomes and general health as perceived by the patients. The authors evaluated self-assessed health-related quality of life (HR-QOL) and vision-related QOL (VR-QOL) in patients before and after endoscopic resection of pituitary adenomas. METHODS The authors prospectively collected data from 50 patients who underwent endoscopic resection of pituitary adenomas. This cohort included 32 patients (64%) with visual impairment preoperatively. Twenty-seven patients (54%) had pituitary dysfunction, including 17 (34%) with hormone-producing tumors. Patients completed the National Eye Institute Visual Functioning Questionnaire and the 36-Item Short Form Health Survey preoperatively and 6 weeks and 6 months after surgery. RESULTS Patients with preoperative visual impairment reported a significant impact of this condition on VR-QOL preoperatively, including general vision, near activities, and peripheral vision; they also noted vision-specific impacts on mental health, role difficulties, dependency, and driving. After endoscopic resection of adenomas, patients reported improvement across all these categories 6 weeks postoperatively, and this improvement was maintained by 6 months postoperatively. Patients with preoperative pituitary dysfunction, including hormone-producing tumors, perceived their general health and physical function as poorer, with some of these patients reporting improvement in perceived general health after the endoscopic surgery. All patients noted that their ability to work or perform activities of daily living was transiently reduced 6 weeks postoperatively, followed by significant improvement by 6 months after the surgery. CONCLUSIONS Both VR-QOL and patient's perceptions of their ability to do work and

  20. Quality of life in Nepalese patients with low vision and the impact of low vision services

    Directory of Open Access Journals (Sweden)

    Rajendra Gyawali

    2012-10-01

    Conclusions: Low vision patients have poor quality of life as measured with the NEI VFQ-25. Low vision service is associated with improved visual function, better quality of life and high rate of patient satisfaction.

  1. Peripheral Circulatory Features during High-Frequency Jet Ventilation

    Directory of Open Access Journals (Sweden)

    M. B. Kontorovich

    2010-01-01

    Full Text Available The paper gives the results of a study of peripheral circulatory features during high-frequency jet ventilation (HFJV. The main specific features of peripheral circulation and oxygen transport during HFJV are formulated on the basis of a study of cardiac output (impedance cardiography, peripheral vascular resistance, peripheral vascular blood filling (photoplethysmogram analysis, adaptive peripheral blood flow reactions (spectral analysis of peripheral vascular pulsation. HFJV gives rise to the peculiar pattern of peripheral hemodynamics and tissue gas exchange, which is characterized by higher oxygen uptake without a decrease in mixed venous blood saturation, with normal extraction coefficient and preserved low peripheral vascular resistance. During HFJV, unlike traditional ventilation, the main peripheral hemodynamic feature is the increased capillary bed blood volume caused by the blood flow involvement of reserve capillaries under control of volume (parasympathetic regulation of adaptive peripheral hemodynamic reactions. Key words: high-frequency jet ventilation, oxygen transport, peripheral hemodynamics.

  2. Functional vision loss: a diagnosis of exclusion.

    Science.gov (United States)

    Villegas, Rex B; Ilsen, Pauline F

    2007-10-01

    Most cases of visual acuity or visual field loss can be attributed to ocular pathology or ocular manifestations of systemic pathology. They can also occasionally be attributed to nonpathologic processes or malingering. Functional vision loss is any decrease in vision the origin of which cannot be attributed to a pathologic or structural abnormality. Two cases of functional vision loss are described. In the first, a 58-year-old man presented for a baseline eye examination for enrollment in a vision rehabilitation program. He reported bilateral blindness since a motor vehicle accident with head trauma 4 years prior. Entering visual acuity was "no light perception" in each eye. Ocular health examination was normal and the patient made frequent eye contact with the examiners. He was referred for neuroimaging and electrophysiologic testing. The second case was a 49-year-old man who presented with a long history of intermittent monocular diplopia. His medical history was significant for psycho-medical evaluations and a diagnosis of factitious disorder. Entering uncorrected visual acuities were 20/20 in each eye, but visual field testing found constriction. No abnormalities were found that could account for the monocular diplopia or visual field deficit. A diagnosis of functional vision loss secondary to factitious disorder was made. Functional vision loss is a diagnosis of exclusion. In the event of reduced vision in the context of a normal ocular health examination, all other pathology must be ruled out before making the diagnosis of functional vision loss. Evaluation must include auxiliary ophthalmologic testing, neuroimaging of the visual pathway, review of the medical history and lifestyle, and psychiatric evaluation. Comanagement with a psychiatrist is essential for patients with functional vision loss.

  3. From Vision to Actuality: Translating the Organizing Vision of Mobile Technology in Home Care

    DEFF Research Database (Denmark)

    Jensen, Tina Blegind; Agger Nielsen, Jeppe

    Empirical evidence from a case study of the diffusion and adoption of mobile technology in a highly structured home care setting in Denmark shows how an organizational field vision of an efficient mobile technology was created and became transformed through diverse translation mechanisms...... the organizing vision for mobile technology in practice. Our findings show that an integration of the translation perspective not only furthers our understanding of the malleability of the organizing vision but also shows how actions at multiple levels interact to enable technology adoption and eventually...... institutionalization. Our study contributes to the increasing research on diffusion and adoption of mobile technologies within healthcare by challenging dominant single level analysis and factor-orientated approaches....

  4. Robot vision for nuclear advanced robot

    International Nuclear Information System (INIS)

    Nakayama, Ryoichi; Okano, Hideharu; Kuno, Yoshinori; Miyazawa, Tatsuo; Shimada, Hideo; Okada, Satoshi; Kawamura, Astuo

    1991-01-01

    This paper describes Robot Vision and Operation System for Nuclear Advanced Robot. This Robot Vision consists of robot position detection, obstacle detection and object recognition. With these vision techniques, a mobile robot can make a path and move autonomously along the planned path. The authors implemented the above robot vision system on the 'Advanced Robot for Nuclear Power Plant' and tested in an environment mocked up as nuclear power plant facilities. Since the operation system for this robot consists of operator's console and a large stereo monitor, this system can be easily operated by one person. Experimental tests were made using the Advanced Robot (nuclear robot). Results indicate that the proposed operation system is very useful, and can be operate by only person. (author)

  5. Integrating National Space Visions

    Science.gov (United States)

    Sherwood, Brent

    2006-01-01

    This paper examines value proposition assumptions for various models nations may use to justify, shape, and guide their space programs. Nations organize major societal investments like space programs to actualize national visions represented by leaders as investments in the public good. The paper defines nine 'vision drivers' that circumscribe the motivations evidently underpinning national space programs. It then describes 19 fundamental space activity objectives (eight extant and eleven prospective) that nations already do or could in the future use to actualize the visions they select. Finally the paper presents four contrasting models of engagement among nations, and compares these models to assess realistic pounds on the pace of human progress in space over the coming decades. The conclusion is that orthogonal engagement, albeit unlikely because it is unprecedented, would yield the most robust and rapid global progress.

  6. Applications of AI, machine vision and robotics

    CERN Document Server

    Boyer, Kim; Bunke, H

    1995-01-01

    This text features a broad array of research efforts in computer vision including low level processing, perceptual organization, object recognition and active vision. The volume's nine papers specifically report on topics such as sensor confidence, low level feature extraction schemes, non-parametric multi-scale curve smoothing, integration of geometric and non-geometric attributes for object recognition, design criteria for a four degree-of-freedom robot head, a real-time vision system based on control of visual attention and a behavior-based active eye vision system. The scope of the book pr

  7. Peripheral blood leukocyte count as an index of defense status in the leukopenic host

    International Nuclear Information System (INIS)

    Cawley, S.; Findon, G.; Miller, T.E.

    1988-01-01

    These experimental studies have investigated the reliability of the peripheral blood leukocyte count to predict whether the leukopenic host can contain or eliminate infection. Additionally, we have investigated the possibility that determination of leukocyte recruitment, supplementary to peripheral blood leukocyte counts, might allow individuals with neutropenia at risk from serious infection to be distinguished with greater certainty. Varying doses of radiation, cyclophosphamide, and methylprednisolone were used to induce distinct levels of leukopenia in rats. Leukocyte recruitment was measured by quantifying the response of neutropenic animals to evocative, subcutaneous stimuli, and the results of this assay were then compared with circulating leukocyte counts in the same individuals. Six models of experimentally induced infection were used to compare circulating and recruitable leukocytes as indicators of the susceptibility of the leukopenic host to infection. Response curves relating leukocyte numbers to host resistance were similar when circulating or recruitable leukocytes were used as an index of defense capability. These findings support the use of peripheral blood leukocyte numbers as an index of resistance to infection in individuals with leukopenia and suggest that functional analyses such as leukocyte recruitment are unlikely to provide additional information

  8. The sustainable nuclear energy technology platform. A vision report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    Nuclear fission energy can deliver safe, sustainable, competitive and practically carbon-free energy to Europe's citizens and industries. Within the framework of the Strategic Energy Technology Plan (SET Plan), the European Commission's stakeholders in this field have formulated a collective vision of the contributions this energy could make towards Europe's transition to a low-carbon energy mix by 2050, with the aim of integrating and expanding R and D capabilities in order to further this objective. The groundwork has been prepared by the stakeholders listed in Annex II, within the framework of two EURATOM FP6 (Sixth Framework Programme) Coordination Actions, namely SNF-TP (Sustainable Nuclear Fission Technology Platform) and PATEROS (Partitioning and Transmutation European Road-map for Sustainable Nuclear Energy), with contributions from Europe's technical safety organisations. This vision report prepares the launch of the European Technology Platform on Sustainable Nuclear Energy (SNE-TP). It proposes a vision for the short-, medium- and long-term development of nuclear fission energy technologies, with the aim of achieving a sustainable production of nuclear energy, a significant progress in economic performance, and a continuous improvement of safety levels as well as resistance to proliferation. In particular, this document proposes road-maps for the development and deployment of potentially sustainable nuclear technologies, as well as actions to harmonize Europe's training and education, whilst renewing its research infrastructures. Public acceptance is also an important issue for the development of nuclear energy. Therefore, research in the fields of nuclear installation safety, protection of workers and populations against radiation, management of all types of waste, and governance methodologies with public participation will be promoted. The proposed road-maps provide the backbone for a strategic research agenda (SRA) to maintain

  9. FPGA Implementation of Computer Vision Algorithm

    OpenAIRE

    Zhou, Zhonghua

    2014-01-01

    Computer vision algorithms, which play an significant role in vision processing, is widely applied in many aspects such as geology survey, traffic management and medical care, etc.. Most of the situations require the process to be real-timed, in other words, as fast as possible. Field Programmable Gate Arrays (FPGAs) have a advantage of parallelism fabric in programming, comparing to the serial communications of CPUs, which makes FPGA a perfect platform for implementing vision algorithms. The...

  10. 21 CFR 886.5915 - Optical vision aid.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Optical vision aid. 886.5915 Section 886.5915 Food... DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5915 Optical vision aid. (a) Identification. An optical vision aid is a device that consists of a magnifying lens with an accompanying AC-powered or...

  11. 21 CFR 886.5540 - Low-vision magnifier.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Low-vision magnifier. 886.5540 Section 886.5540...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5540 Low-vision magnifier. (a) Identification. A low-vision magnifier is a device that consists of a magnifying lens intended for use by a patient...

  12. 21 CFR 886.5870 - Low-vision telescope.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Low-vision telescope. 886.5870 Section 886.5870...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5870 Low-vision telescope. (a) Identification. A low-vision telescope is a device that consists of an arrangement of lenses or mirrors intended for...

  13. VISION- REQUIREMENT FOR A SUCCESSFUL LEADER

    Directory of Open Access Journals (Sweden)

    Angela - Olimpia Lobonea (Oltean

    2014-12-01

    Full Text Available These people were called in the past chiefs, rulers. Now they are known as leaders. After management by objectives, strategic planning, project organization, this concept appears as a tool called "fourth generation". It is called VISION. Leadership and vision exist in the actual sense, which has become modern a few decades ago, managing to gather during this time a variety of scientific instruments. The connection between these two domains creates a certain type of leader, the visionary leader. The hypothesis from which we start is that all active leaders have a vision of what needs to be accomplished, and the inability to predict something that could be provided involves loss the capacity of the leader. Without vision, the energy reaches the lowest quotas, production decreases, terms limits are exceeded and human resources begin to dissipate.. The conclusion is that visionary leaders are endowed with multiple attributes (multiple intelligence, even if sometimes the role of intuition and unconscious in building vision at the expense of reason that is based on experience and facts is exaggerated.

  14. Divergence of dim-light vision among bats (order: Chiroptera) as estimated by molecular and electrophysiological methods.

    Science.gov (United States)

    Liu, He-Qun; Wei, Jing-Kuan; Li, Bo; Wang, Ming-Shan; Wu, Rui-Qi; Rizak, Joshua D; Zhong, Li; Wang, Lu; Xu, Fu-Qiang; Shen, Yong-Yi; Hu, Xin-Tian; Zhang, Ya-Ping

    2015-06-23

    Dim-light vision is present in all bats, but is divergent among species. Old-World fruit bats (Pteropodidae) have fully developed eyes; the eyes of insectivorous bats are generally degraded, and these bats rely on well-developed echolocation. An exception is the Emballonuridae, which are capable of laryngeal echolocation but prefer to use vision for navigation and have normal eyes. In this study, integrated methods, comprising manganese-enhanced magnetic resonance imaging (MEMRI), f-VEP and RNA-seq, were utilized to verify the divergence. The results of MEMRI showed that Pteropodidae bats have a much larger superior colliculus (SC)/ inferior colliculus (IC) volume ratio (3:1) than insectivorous bats (1:7). Furthermore, the absolute visual thresholds (log cd/m(2)•s) of Pteropodidae (-6.30 and -6.37) and Emballonuridae (-3.71) bats were lower than those of other insectivorous bats (-1.90). Finally, genes related to the visual pathway showed signs of positive selection, convergent evolution, upregulation and similar gene expression patterns in Pteropodidae and Emballonuridae bats. Different results imply that Pteropodidae and Emballonuridae bats have more developed vision than the insectivorous bats and suggest that further research on bat behavior is warranted.

  15. The Rate of Low Vision Aids Usage after Prescription at the Saba and Khazaneh Clinics in Low Vision Clients

    Directory of Open Access Journals (Sweden)

    Nasser Sadegh-Pour

    2008-04-01

    Full Text Available Objective: This research was aimed to determine the rate of low vision aids uses by low vision clients in their daily living. Materials & Methods: In this descriptive study that was done at the Saba and Khazaneh clinics, 50 people from low vision clients were selected by convenient sampling during 2005 & 2006. One questionnaire was completed by therapist at the first time of optometric examination and useful low vision aid (LVA has been prescript and given to clients. After three months (at least they should came back to center and fill the second form. The first form was about functional vision without LVA and second too, but by using of LVA. They have been compared to fulfill the result of research. Data were analyzed by Spearman correlation coefficient, Chi – square and Wilcoxon tests. Results: Spearman correlation coefficient between use of LVAs for near with duration and frequency of study were 0/491 and 0/520 with probability values such as P=0/003 and P=0/002 that shown significant relation. There was significant difference in traffic measure and environment knowing between before and after of far LVAs using (P=0/002 and their SCC was 0/499. There was significant relation between use of low vision aid and education after prescription (P=0/011. Conclusion: However the LVAs improve vision of low vision person, but many of them don’t use by different reasons.

  16. Motion-Base Simulator Evaluation of an Aircraft Using an External Vision System

    Science.gov (United States)

    Kramer, Lynda J.; Williams, Steven P.; Arthur, J. J.; Rehfeld, Sherri A.; Harrison, Stephanie

    2012-01-01

    Twelve air transport-rated pilots participated as subjects in a motion-base simulation experiment to evaluate the use of eXternal Vision Systems (XVS) as enabling technologies for future supersonic aircraft without forward facing windows. Three head-up flight display concepts were evaluated -a monochromatic, collimated Head-up Display (HUD) and a color, non-collimated XVS display with a field-of-view (FOV) equal to and also, one significantly larger than the collimated HUD. Approach, landing, departure, and surface operations were conducted. Additionally, the apparent angle-of-attack (AOA) was varied (high/low) to investigate the vertical field-of-view display requirements and peripheral, side window visibility was experimentally varied. The data showed that lateral approach tracking performance and lateral landing position were excellent regardless of AOA, display FOV, display collimation or whether peripheral cues were present. However, the data showed glide slope approach tracking appears to be affected by display size (i.e., FOV) and collimation. The monochrome, collimated HUD and color, uncollimated XVS with Full FOV display had (statistically equivalent) glide path performance improvements over the XVS with HUD FOV display. Approach path performance results indicated that collimation may not be a requirement for an XVS display if the XVS display is large enough and employs color. Subjective assessments of mental workload and situation awareness also indicated that an uncollimated XVS display may be feasible. Motion cueing appears to have improved localizer tracking and touchdown sink rate across all displays.

  17. China Naval Modernization: Implications for U.S. Navy Capabilities - Background and Issues for Congress

    Science.gov (United States)

    2014-06-05

    Helicopters n/a n/a n/a n/a ~34 ~153 ~157 Subtotal above aircraft n/a n/a n/a n/a ~179 ~468 ~ 505 Source: Prepared by CRS. Source for 2009, 2015, and...capable of attack-in-depth to disrupt. destroy and defeat adversary forces ( NIA /03). ASB’s vision of networked, integrated, and attack-in-depth ( NIA ...forces with the aforementioned NIA -D3 capabil ities that will help ensure freedom of access in the global commons. The ASB Concept is intended to

  18. Color Vision Defects in School Going Children

    Directory of Open Access Journals (Sweden)

    R K Shrestha

    2010-12-01

    Full Text Available Introduction: Color Vision defect can be observed in various diseases of optic nerve and retina and also a significant number of people suffer from the inherited condition of red and green color defect. Methods: A cross-sectional descritptive study was designed with purposive sampling of students from various schools of Kathmandu Valley. All children were subjected to color vision evaluation using Ishihara Isochromatic color plates along with other examination to rule out any other causes of color deficiency. Results: A total of 2001 students were examined, 1050 male students and 951 females with mean age of 10.35 (±2.75 and 10.54 (±2.72 respectively. Among the total students examined, 2.1% had some form of color vision defects. Of the male population , 3.9% had color vision defects while none of the female was found with the deficiency. Conclusions: The prelevance of color vision defect in Nepal is significant and comparable with the prelevance quoted in the studies from different countries. Keywords:color vision; congenital red green color effect; Nepal; prevalence.

  19. Management Matters. Nurture Your Vision

    Science.gov (United States)

    Pappas, Marjorie L.

    2005-01-01

    In many professional roles, long-term vision may help guide short-term decisions. This is especially true for school library professionals as library media programs are constantly evolving. This author suggests strategies to assist library media specialists to nurture their vision and provides reviews of several sources and experts in the field…

  20. Peripherally applied opioids for postoperative pain

    DEFF Research Database (Denmark)

    Nielsen, B N; Henneberg, S W; Schmiegelow, K

    2015-01-01

    BACKGROUND: Opioids applied peripherally at the site of surgery may produce postoperative analgesia with few side effects. We performed this systematic review to evaluate the analgesic effect of peripherally applied opioids for acute postoperative pain. METHODS: We searched PubMed (1966 to June...... 2013), Embase (1980 to June 2013), and the Cochrane Central Register of Controlled Trials (The Cochrane Library 2013, Issue 6). Randomized controlled trials investigating the postoperative analgesic effect of peripherally applied opioids vs. systemic opioids or placebo, measured by pain intensity...... difference -5 mm, 95% CI: -7 to -3) for peripherally applied opioids vs. placebo and statistically significant increased time to first analgesic (mean difference 153 min, 95% CI: 41-265). When preoperative inflammation was reported (five studies), peripherally applied opioids significantly improved...

  1. Low-dose radiation (LDR) induces hematopoietic hormesis: LDR-induced mobilization of hematopoietic progenitor cells into peripheral blood circulation.

    Science.gov (United States)

    Li, Wei; Wang, Guanjun; Cui, Jiuwei; Xue, Lu; Cai, Lu

    2004-11-01

    The aim of this study was to investigate the stimulating effect of low-dose radiation (LDR) on bone marrow hematopoietic progenitor cell (HPC) proliferation and peripheral blood mobilization. Mice were exposed to 25- to 100-mGy x-rays. Bone marrow and peripheral blood HPCs (BFU-E, CFU-GM, and c-kit+ cells) were measured, and GM-CSF, G-CSF, and IL-3 protein and mRNA expression were detected using ELISA, slot blot hybridization, and Northern blot methods. To functionally evaluate LDR-stimulated and -mobilized HPCs, repopulation of peripheral blood cells in lethally irradiated recipients after transplantation of LDR-treated donor HPCs was examined by WBC counts, animal survival, and colony-forming units in the recipient spleens (CFUs-S). 75-mGy x-rays induced a maximal stimulation for bone marrow HPC proliferation (CFU-GM and BFU-E formation) 48 hours postirradiation, along with a significant increase in HPC mobilization into peripheral blood 48 to 72 hours postradiation, as shown by increases in CFU-GM formation and proportion of c-kit+ cells in the peripheral mononuclear cells. 75-mGy x-rays also maximally induced increases in G-CSF and GM-CSF mRNA expression in splenocytes and levels of serum GM-CSF. To define the critical role of these hematopoietic-stimulating factors in HPC peripheral mobilization, direct administration of G-CSF at a dose of 300 microg/kg/day or 150 microg/kg/day was applied and found to significantly stimulate GM-CFU formation and increase c-kit+ cells in the peripheral mononuclear cells. More importantly, 75-mGy x-rays plus 150 microg/kg/day G-CSF (LDR/150-G-CSF) produced a similar effect to that of 300 microg/kg/day G-CSF alone. Furthermore, the capability of LDR-mobilized donor HPCs to repopulate blood cells was confirmed in lethally irradiated recipient mice by counting peripheral WBC and CFUs-S. These results suggest that LDR induces hematopoietic hormesis, as demonstrated by HPC proliferation and peripheral mobilization, providing a

  2. The transect of happiness and community’s capability in urbanizing Yogyakarta

    Science.gov (United States)

    Pramono, RWD

    2018-03-01

    The idea of this paper is that happy-friendly city is it that able to support capability. In addition to factors affixed to an individual, an important element determining someone’s happiness is the quality of a place. This research tries to explain the role of quality of place formed by urbanization process by taking Yogyakarta case as the sample. The importance of variation of particular area caused by urbanization is revealed using transect method. This method showed the shifting gradation from the very center of the city that first experienced urbanization up to the peripheral that experienced it last. The initial result of this clustered-multistage random sampling shows a gradation in capability. It also describes the similar tendency regarding self-evaluation against happiness although not very clear. Further analysis is conducted to define influencing factors. They consist of 40 capability assets that belong to Individual Tangible Asset, Public Tangible Asset, Individual Intangible Asset, Social Institutional Asset, and Economic Institutional Asset. However, the focus of analysis will be on variables included in Public Tangible Asset, Social Institutional Asset, and Economic Institutional Asset called as place-attached assets.

  3. High-resolution ultrasound imaging and noninvasive optoacoustic monitoring of blood variables in peripheral blood vessels

    Science.gov (United States)

    Petrov, Irene Y.; Petrov, Yuriy; Prough, Donald S.; Esenaliev, Rinat O.

    2011-03-01

    Ultrasound imaging is being widely used in clinics to obtain diagnostic information non-invasively and in real time. A high-resolution ultrasound imaging platform, Vevo (VisualSonics, Inc.) provides in vivo, real-time images with exceptional resolution (up to 30 microns) using high-frequency transducers (up to 80 MHz). Recently, we built optoacoustic systems for probing radial artery and peripheral veins that can be used for noninvasive monitoring of total hemoglobin concentration, oxyhemoglobin saturation, and concentration of important endogenous and exogenous chromophores (such as ICG). In this work we used the high-resolution ultrasound imaging system Vevo 770 for visualization of the radial artery and peripheral veins and acquired corresponding optoacoustic signals from them using the optoacoustic systems. Analysis of the optoacoustic data with a specially developed algorithm allowed for measurement of blood oxygenation in the blood vessels as well as for continuous, real-time monitoring of arterial and venous blood oxygenation. Our results indicate that: 1) the optoacoustic technique (unlike pure optical approaches and other noninvasive techniques) is capable of accurate peripheral venous oxygenation measurement; and 2) peripheral venous oxygenation is dependent on skin temperature and local hemodynamics. Moreover, we performed for the first time (to the best of our knowledge) a comparative study of optoacoustic arterial oximetry and a standard pulse oximeter in humans and demonstrated superior performance of the optoacoustic arterial oximeter, in particular at low blood flow.

  4. Color in Computer Vision Fundamentals and Applications

    CERN Document Server

    Gevers, Theo; van de Weijer, Joost; Geusebroek, Jan-Mark

    2012-01-01

    While the field of computer vision drives many of today’s digital technologies and communication networks, the topic of color has emerged only recently in most computer vision applications. One of the most extensive works to date on color in computer vision, this book provides a complete set of tools for working with color in the field of image understanding. Based on the authors’ intense collaboration for more than a decade and drawing on the latest thinking in the field of computer science, the book integrates topics from color science and computer vision, clearly linking theor

  5. HIV-1 phylogenetic analysis shows HIV-1 transits through the meninges to brain and peripheral tissues.

    Science.gov (United States)

    Lamers, Susanna L; Gray, Rebecca R; Salemi, Marco; Huysentruyt, Leanne C; McGrath, Michael S

    2011-01-01

    Brain infection by the human immunodeficiency virus type 1 (HIV-1) has been investigated in many reports with a variety of conclusions concerning the time of entry and degree of viral compartmentalization. To address these diverse findings, we sequenced HIV-1 gp120 clones from a wide range of brain, peripheral and meningeal tissues from five patients who died from several HIV-1 associated disease pathologies. High-resolution phylogenetic analysis confirmed previous studies that showed a significant degree of compartmentalization in brain and peripheral tissue subpopulations. Some intermixing between the HIV-1 subpopulations was evident, especially in patients that died from pathologies other than HIV-associated dementia. Interestingly, the major tissue harboring virus from both the brain and peripheral tissues was the meninges. These results show that (1) HIV-1 is clearly capable of migrating out of the brain, (2) the meninges are the most likely primary transport tissues, and (3) infected brain macrophages comprise an important HIV reservoir during highly active antiretroviral therapy. Copyright © 2010 Elsevier B.V. All rights reserved.

  6. Ecstasy and vision

    Directory of Open Access Journals (Sweden)

    Anders Hultgård

    1981-01-01

    Full Text Available In this paper we shall present some observations on the role played by ecstasy in the activity of the seer, as he emerges in ancient Jewish and Iranian texts. In the Jewish religious literature of the Hellenistic-Roman period, visions are described on almost every page, and visions were the most important means of divine revelation. Specific techniques for inducing the ecstatic state are not recorded in the Jewish sources. Some elements in the pattern leading up to the vision may be interpreted as parts of a method for inducing the final ecstasy; i.e. fasting and prayer. The Iranian material shows clearly the importance of ecstasy in the activity of the seer. The ecstatic seeing also means that the visionary shares with Ahura Mazda a divine quality, the "wisdom of omniscience". The granting of the "wisdom of omniscience" appears as a temporary and it conveys to the visionary a supernatural seeing. There is evidence to suggest that chanting was an important method of inducing ecstasy within the early Zoroastrian community. We do not find in the Jewish material a clear correspondence to the Iranian notion of "omniscient wisdom".

  7. Limits of colour vision in dim light.

    Science.gov (United States)

    Kelber, Almut; Lind, Olle

    2010-09-01

    Humans and most vertebrates have duplex retinae with multiple cone types for colour vision in bright light, and one single rod type for achromatic vision in dim light. Instead of comparing signals from multiple spectral types of photoreceptors, such species use one highly sensitive receptor type thus improving the signal-to-noise ratio at night. However, the nocturnal hawkmoth Deilephila elpenor, the nocturnal bee Xylocopa tranquebarica and the nocturnal gecko Tarentola chazaliae can discriminate colours at extremely dim light intensities. To be able to do so, they sacrifice spatial and temporal resolution in favour of colour vision. We review what is known about colour vision in dim light, and compare colour vision thresholds with the optical sensitivity of the photoreceptors in selected animal species with lens and compound eyes. © 2010 The Authors, Ophthalmic and Physiological Optics © 2010 The College of Optometrists.

  8. Burn-related peripheral neuropathy: A systematic review.

    Science.gov (United States)

    Tu, Yiji; Lineaweaver, William C; Zheng, Xianyou; Chen, Zenggan; Mullins, Fred; Zhang, Feng

    2017-06-01

    Peripheral neuropathy is the most frequent disabling neuromuscular complication of burns. However, the insidious and progressive onset of burn neuropathy makes it often undiagnosed or overlooked. In our study, we reviewed the current studies on the burn-related peripheral neuropathy to summarize the morbidity, mechanism, detecting method and management of peripheral neuropathy in burn patients. Of the 1533 burn patients included in our study, 98 cases (6.39%) were presented with peripheral neuropathy. Thermal and electrical burns were the most common etiologies. Surgical procedures, especially nerve decompression, showed good effect on functional recovery of both acute and delayed peripheral neuropathy in burn patients. It is noteworthy that, for early detection and prevention of peripheral neuropathy, electrodiagnostic examinations should be performed on burn patients independent of symptoms. Still, the underlying mechanisms of burn-related peripheral neuropathy remain to be clarified. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  9. Vision training methods for sports concussion mitigation and management.

    Science.gov (United States)

    Clark, Joseph F; Colosimo, Angelo; Ellis, James K; Mangine, Robert; Bixenmann, Benjamin; Hasselfeld, Kimberly; Graman, Patricia; Elgendy, Hagar; Myer, Gregory; Divine, Jon

    2015-05-05

    There is emerging evidence supporting the use vision training, including light board training tools, as a concussion baseline and neuro-diagnostic tool and potentially as a supportive component to concussion prevention strategies. This paper is focused on providing detailed methods for select vision training tools and reporting normative data for comparison when vision training is a part of a sports management program. The overall program includes standard vision training methods including tachistoscope, Brock's string, and strobe glasses, as well as specialized light board training algorithms. Stereopsis is measured as a means to monitor vision training affects. In addition, quantitative results for vision training methods as well as baseline and post-testing *A and Reaction Test measures with progressive scores are reported. Collegiate athletes consistently improve after six weeks of training in their stereopsis, *A and Reaction Test scores. When vision training is initiated as a team wide exercise, the incidence of concussion decreases in players who participate in training compared to players who do not receive the vision training. Vision training produces functional and performance changes that, when monitored, can be used to assess the success of the vision training and can be initiated as part of a sports medical intervention for concussion prevention.

  10. Real-time vision systems

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, R.; Hernandez, J.E.; Lu, Shin-yee [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    Many industrial and defence applications require an ability to make instantaneous decisions based on sensor input of a time varying process. Such systems are referred to as `real-time systems` because they process and act on data as it occurs in time. When a vision sensor is used in a real-time system, the processing demands can be quite substantial, with typical data rates of 10-20 million samples per second. A real-time Machine Vision Laboratory (MVL) was established in FY94 to extend our years of experience in developing computer vision algorithms to include the development and implementation of real-time vision systems. The laboratory is equipped with a variety of hardware components, including Datacube image acquisition and processing boards, a Sun workstation, and several different types of CCD cameras, including monochrome and color area cameras and analog and digital line-scan cameras. The equipment is reconfigurable for prototyping different applications. This facility has been used to support several programs at LLNL, including O Division`s Peacemaker and Deadeye Projects as well as the CRADA with the U.S. Textile Industry, CAFE (Computer Aided Fabric Inspection). To date, we have successfully demonstrated several real-time applications: bullet tracking, stereo tracking and ranging, and web inspection. This work has been documented in the ongoing development of a real-time software library.

  11. Understanding Innovation for Sustainable Business Management Capabilities and Competencies under Uncertainty

    Directory of Open Access Journals (Sweden)

    Kuo-Jui Wu

    2015-10-01

    Full Text Available In recent years, many firms have come to understand that innovation is an important issue in sustainable business management, as it helps improve firm capabilities and competencies. Because of the fiercely competitive environment in the hotel industry, innovation has become a critical factor in the process of hotel differentiation, leading to sustainable business success. However, the literature has not thoroughly examined the role of innovation or the hierarchical structure of the capabilities and competencies in sustainable business management. This study adopts interval-valued triangular fuzzy numbers and grey relational analysis to provide a competitive priority ranking for the aspects and criteria that assist firms in decision-making. The study results indicate that innovation in technology capabilities and networking and social capabilities—in addition to competencies in systemic thinking—are the most important aspects of sustainable business management. In particular, this study indicates that to succeed in building a sustainable business in the hotel industry, firms should upgrade and integrate their business technologies, collaborate with actors inside and outside the firm, build trust as well as a shared vision that includes common agreement, and develop competencies in inventive thinking to support innovation and foster changes in strategy, structure, administrative procedures, and systems when necessary.

  12. Managing Dreams and Ambitions: A Psychological Analysis of Vision Communication

    NARCIS (Netherlands)

    D.A. Stam (Daan)

    2008-01-01

    textabstractThe communication of inspiring visions is arguably the sine qua non of change-oriented leadership. Visions are images of the future. Vision communication refers to the expression of a vision with the aim of convincing others (usually followers) that the vision is valid. Despite the fact

  13. [Ophthalmologist and "computer vision syndrome"].

    Science.gov (United States)

    Barar, A; Apatachioaie, Ioana Daniela; Apatachioaie, C; Marceanu-Brasov, L

    2007-01-01

    The authors had tried to collect the data available on the Internet about a subject that we consider as being totally ignored in the Romanian scientific literature and unexpectedly insufficiently treated in the specialized ophthalmologic literature. Known in the specialty literature under the generic name of "Computer vision syndrome", it is defined by the American Optometric Association as a complex of eye and vision problems related to the activities which stress the near vision and which are experienced in relation, or during, the use of the computer. During the consultations we hear frequent complaints of eye-strain - asthenopia, headaches, blurred distance and/or near vision, dry and irritated eyes, slow refocusing, neck and backache, photophobia, sensation of diplopia, light sensitivity, and double vision, but because of the lack of information, we overlooked them too easily, without going thoroughly into the real motives. In most of the developed countries, there are recommendations issued by renowned medical associations with regard to the definition, the diagnosis, and the methods for the prevention, treatment and periodical control of the symptoms found in computer users, in conjunction with an extremely detailed ergonomic legislation. We found out that these problems incite a much too low interest in our country. We would like to rouse the interest of our ophthalmologist colleagues in the understanding and the recognition of these symptoms and in their treatment, or at least their improvement, through specialized measures or through the cooperation with our specialist occupational medicine colleagues.

  14. Embedded Active Vision System Based on an FPGA Architecture

    Directory of Open Access Journals (Sweden)

    Chalimbaud Pierre

    2007-01-01

    Full Text Available In computer vision and more particularly in vision processing, the impressive evolution of algorithms and the emergence of new techniques dramatically increase algorithm complexity. In this paper, a novel FPGA-based architecture dedicated to active vision (and more precisely early vision is proposed. Active vision appears as an alternative approach to deal with artificial vision problems. The central idea is to take into account the perceptual aspects of visual tasks, inspired by biological vision systems. For this reason, we propose an original approach based on a system on programmable chip implemented in an FPGA connected to a CMOS imager and an inertial set. With such a structure based on reprogrammable devices, this system admits a high degree of versatility and allows the implementation of parallel image processing algorithms.

  15. Embedded Active Vision System Based on an FPGA Architecture

    Directory of Open Access Journals (Sweden)

    Pierre Chalimbaud

    2006-12-01

    Full Text Available In computer vision and more particularly in vision processing, the impressive evolution of algorithms and the emergence of new techniques dramatically increase algorithm complexity. In this paper, a novel FPGA-based architecture dedicated to active vision (and more precisely early vision is proposed. Active vision appears as an alternative approach to deal with artificial vision problems. The central idea is to take into account the perceptual aspects of visual tasks, inspired by biological vision systems. For this reason, we propose an original approach based on a system on programmable chip implemented in an FPGA connected to a CMOS imager and an inertial set. With such a structure based on reprogrammable devices, this system admits a high degree of versatility and allows the implementation of parallel image processing algorithms.

  16. In vivo targeted gene delivery to peripheral neurons mediated by neurotropic poly(ethylene imine-based nanoparticles

    Directory of Open Access Journals (Sweden)

    Lopes CDF

    2016-06-01

    Full Text Available Cátia DF Lopes,1–3,* Hugo Oliveira,1,* Inês Estevão,1 Liliana Raquel Pires,1 Ana Paula Pêgo1,2,4,5 1INEB – Instituto de Engenharia Biomédica, Universidade do Porto (UPorto, Porto, Portugal; 2i3S – Instituto de Investigação e Inovação em Saúde, NanoBiomaterials for Targeted Therapies Group, UPorto, Porto, Portugal; 3FMUP – Faculdade de Medicina da Universidade do Porto, Porto, Portugal; 4ICBAS – Instituto de Ciências Biomédicas Abel Salazar, UPorto, Porto, Portugal; 5FEUP – Faculdade de Engenharia da Universidade do Porto, Porto, Portugal *These authors contributed equally to this work Abstract: A major challenge in neuronal gene therapy is to achieve safe, efficient, and minimally invasive transgene delivery to neurons. In this study, we report the use of a nonviral neurotropic poly(ethylene imine-based nanoparticle that is capable of mediating neuron-specific transfection upon a subcutaneous injection. Nanoparticles were targeted to peripheral neurons by using the nontoxic carboxylic fragment of tetanus toxin (HC, which, besides being neurotropic, is capable of being retrogradely transported from neuron terminals to the cell bodies. Nontargeted particles and naked plasmid DNA were used as control. Five days after treatment by subcutaneous injection in the footpad of Wistar rats, it was observed that 56% and 64% of L4 and L5 dorsal root ganglia neurons, respectively, were expressing the reporter protein. The delivery mediated by HC-functionalized nanoparticles spatially limited the transgene expression, in comparison with the controls. Histological examination revealed no significant adverse effects in the use of the proposed delivery system. These findings demonstrate the feasibility and safety of the developed neurotropic nanoparticles for the minimally invasive delivery of genes to the peripheral nervous system, opening new avenues for the application of gene therapy strategies in the treatment of peripheral

  17. En vision for CBS?

    DEFF Research Database (Denmark)

    Thyssen, Ole

    2015-01-01

    Kommentar. CBS’ ry for at være et moderne Business University med forskere fra hele verden og forskningsmæssig dynamik faldt på gulvet. Udfordringen er nu at få samlet CBS forskere om en fælles vision.......Kommentar. CBS’ ry for at være et moderne Business University med forskere fra hele verden og forskningsmæssig dynamik faldt på gulvet. Udfordringen er nu at få samlet CBS forskere om en fælles vision....

  18. Ultraviolet vision may be widespread in bats

    Science.gov (United States)

    Gorresen, P. Marcos; Cryan, Paul; Dalton, David C.; Wolf, Sandy; Bonaccorso, Frank

    2015-01-01

    Insectivorous bats are well known for their abilities to find and pursue flying insect prey at close range using echolocation, but they also rely heavily on vision. For example, at night bats use vision to orient across landscapes, avoid large obstacles, and locate roosts. Although lacking sharp visual acuity, the eyes of bats evolved to function at very low levels of illumination. Recent evidence based on genetics, immunohistochemistry, and laboratory behavioral trials indicated that many bats can see ultraviolet light (UV), at least at illumination levels similar to or brighter than those before twilight. Despite this growing evidence for potentially widespread UV vision in bats, the prevalence of UV vision among bats remains unknown and has not been studied outside of the laboratory. We used a Y-maze to test whether wild-caught bats could see reflected UV light and whether such UV vision functions at the dim lighting conditions typically experienced by night-flying bats. Seven insectivorous species of bats, representing five genera and three families, showed a statistically significant ‘escape-toward-the-light’ behavior when placed in the Y-maze. Our results provide compelling evidence of widespread dim-light UV vision in bats.

  19. Vision and vision-related outcome measures in multiple sclerosis

    DEFF Research Database (Denmark)

    Balcer, Laura J; Miller, David H; Reingold, Stephen C

    2015-01-01

    Visual impairment is a key manifestation of multiple sclerosis. Acute optic neuritis is a common, often presenting manifestation, but visual deficits and structural loss of retinal axonal and neuronal integrity can occur even without a history of optic neuritis. Interest in vision in multiple...... sclerosis is growing, partially in response to the development of sensitive visual function tests, structural markers such as optical coherence tomography and magnetic resonance imaging, and quality of life measures that give clinical meaning to the structure-function correlations that are unique...... of investigators involved in the development and study of visual outcomes in multiple sclerosis, which had, as its overriding goals, to review the state of the field and identify areas for future research. We review data and principles to help us understand the importance of vision as a model for outcomes...

  20. The effect of Medicaid adult vision coverage on the likelihood of appropriate correction of distance vision: Evidence from the National Health and Nutrition Examination Survey.

    Science.gov (United States)

    Lipton, Brandy J; Decker, Sandra L

    2016-02-01

    Medicaid is the main public health insurance program for individuals with low income in the United States. Some state Medicaid programs cover preventive eye care services and vision correction, while others cover emergency eye care only. Similar to other optional benefits, states may add and drop adult vision benefits over time. This article examines whether providing adult vision benefits is associated with an increase in the percentage of low-income individuals with appropriately corrected distance vision as measured during an eye exam. We estimate the effect of Medicaid vision coverage on the likelihood of having appropriately corrected distance vision using examination data from the 2001-2008 National Health and Nutrition Examination Survey. We compare vision outcomes for Medicaid beneficiaries (n = 712) and other low income adults not enrolled in Medicaid (n = 4786) before and after changes to state vision coverage policies. Between 29 and 33 states provided Medicaid adult vision benefits during 2001-2008, depending on the year. Our findings imply that Medicaid adult vision coverage is associated with a significant increase in the percentage of Medicaid beneficiaries with appropriately corrected distance vision of up to 10 percentage points. Providing vision coverage to adults on Medicaid significantly increases the likelihood of appropriate correction of distance vision. Further research on the impact of vision coverage on related functional outcomes and the effects of Medicaid coverage of other services may be appropriate. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Intraoperative Ultrasound for Peripheral Nerve Applications.

    Science.gov (United States)

    Willsey, Matthew; Wilson, Thomas J; Henning, Phillip Troy; Yang, Lynda J-S

    2017-10-01

    Offering real-time, high-resolution images via intraoperative ultrasound is advantageous for a variety of peripheral nerve applications. To highlight the advantages of ultrasound, its extraoperative uses are reviewed. The current intraoperative uses, including nerve localization, real-time evaluation of peripheral nerve tumors, and implantation of leads for peripheral nerve stimulation, are reviewed. Although intraoperative peripheral nerve localization has been performed previously using guide wires and surgical dyes, the authors' approach using ultrasound-guided instrument clamps helps guide surgical dissection to the target nerve, which could lead to more timely operations and shorter incisions. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Evaluation of functional color vision requirements and current color vision screening tests for air traffic control specialists.

    Science.gov (United States)

    1990-08-01

    An experiment was conducted to evaluate the relation of type and degree of color vision deficiency and aeromedical color vision screening test scores to performance of color-dependent tasks of Air Traffic Control Specialists. The subjects included 37...

  3. Functional deficits in peripheral nerve mitochondria in rats with paclitaxel- and oxaliplatin-evoked painful peripheral neuropathy

    OpenAIRE

    Zheng, Huaien; Xiao, Wen Hua; Bennett, Gary J.

    2011-01-01

    Cancer chemotherapeutics like paclitaxel and oxaliplatin produce a dose-limiting chronic sensory peripheral neuropathy that is often accompanied by neuropathic pain. The cause of the neuropathy and pain is unknown. In animal models, paclitaxel-evoked and oxaliplatin-evoked painful peripheral neuropathies are accompanied by an increase in the incidence of swollen and vacuolated mitochondria in peripheral nerve axons. It has been proposed that mitochondrial swelling and vacuolation are indicati...

  4. A visual test based on a freeware software for quantifying and displaying night-vision disturbances: study in subjects after alcohol consumption.

    Science.gov (United States)

    Castro, José J; Ortiz, Carolina; Pozo, Antonio M; Anera, Rosario G; Soler, Margarita

    2014-05-07

    In this work, we propose the Halo test, a simple visual test based on a freeware software for quantifying and displaying night-vision disturbances perceived by subjects under different experimental conditions, more precisely studying the influence of the alcohol consumption on visual function. In the Halo test, viewed on a monitor, the subject's task consists of detecting luminous peripheral stimuli around a central high-luminance stimulus over a dark background. The test, performed by subjects before and after consuming alcoholic drinks, which deteriorate visual performance, evaluates the influence that alcohol consumption exerts on the visual-discrimination capacity under low illumination conditions. Measurements were made monocularly and binocularly. Pupil size was also measured in both conditions (pre/post). Additionally, we used a double-pass device to measure objectively the optical-quality of the eye and corroborate the results from the Halo test. We found a significant deterioration of the discrimination capacity after alcohol consumption, indicating that the higher the breath-alcohol content, the greater the deterioration of the visual-discrimination capacity. After alcohol intake, the graphical results showed a greater area of undetected peripheral stimuli around the central high-luminance stimulus. An enlargement of the pupil was also observed and the optical quality of the eye was deteriorated after alcohol consumption. A greater influence of halos and other night-vision disturbances were reported with the Halo test after alcohol consumption. The Halo freeware software constitutes a positive contribution for evaluating nighttime visual performance in clinical applications, such as reported here, but also in patients after refractive surgery (where halos are present) or for monitoring (time course) some ocular pathologies under pharmacological treatment.

  5. Optoelectronic vision

    Science.gov (United States)

    Ren, Chunye; Parel, Jean-Marie A.

    1993-06-01

    Scientists have searched every discipline to find effective methods of treating blindness, such as using aids based on conversion of the optical image, to auditory or tactile stimuli. However, the limited performance of such equipment and difficulties in training patients have seriously hampered practical applications. A great edification has been given by the discovery of Foerster (1929) and Krause & Schum (1931), who found that the electrical stimulation of the visual cortex evokes the perception of a small spot of light called `phosphene' in both blind and sighted subjects. According to this principle, it is possible to invite artificial vision by using stimulation with electrodes placed on the vision neural system, thereby developing a prosthesis for the blind that might be of value in reading and mobility. In fact, a number of investigators have already exploited this phenomena to produce a functional visual prosthesis, bringing about great advances in this area.

  6. Christina Mosegaards barok-vision

    DEFF Research Database (Denmark)

    Isar, Nicoletta

    2008-01-01

      Christina Mosegaards barok-vision: om folder, ansigter og stilhed Det mest fængslende ved Christinas billeder er ved første øjekast den slående kontrast mellem roen i hendes ikonagtige ansigter og den dramatiske drejende bevægelse i stoffolderne. Men er de nu så radikalt forskellige i deres nat...... under sløret. Hun forbliver tro mod sin særegne vision i ikonerne, som i deres hudvæv gentager det opal-agtige og iriserende i marmorfoldens årer....

  7. Computer vision as an alternative for collision detection

    OpenAIRE

    Drangsholt, Marius Aarvik

    2015-01-01

    The goal of this thesis was to implement a computer vision system on a low power platform, to see if that could be an alternative for a collision detection system. To achieve this, research into fundamentals in computer vision were performed, and both hardware and software implementation were carried out. To create the computer vision system, a stereo rig were constructed using low cost Logitech webcameras, and connected to a Raspberry Pi 2 development board. The computer vision library Op...

  8. Low-level laser therapy improves vision in a patient with retinitis pigmentosa.

    Science.gov (United States)

    Ivandic, Boris T; Ivandic, Tomislav

    2014-03-01

    This case report describes the effects of low-level laser therapy (LLLT) in a single patient with retinitis pigmentosa (RP). RP is a heritable disorder of the retina, which eventually leads to blindness. No therapy is currently available. LLLT was applied using a continuous wave laser diode (780 nm, 10 mW average output at 292 Hz, 50% pulse modulation). The complete retina of eyes was irradiated through the conjunctiva for 40 sec (0.4 J, 0.333 W/cm2) two times per week for 2 weeks (1.6 J). A 55-year-old male patient with advanced RP was treated and followed for 7 years. The patient had complained of nyctalopia and decreasing vision. At first presentation, best visual acuity was 20/50 in each eye. Visual fields were reduced to a central residual of 5 degrees. Tritan-dyschromatopsy was found. Retinal potential was absent in electroretinography. Biomicroscopy showed optic nerve atrophy, and narrow retinal vessels with a typical pattern of retinal pigmentation. After four initial treatments of LLLT, visual acuity increased to 20/20 in each eye. Visual fields normalized except for a mid-peripheral absolute concentric scotoma. Five years after discontinuation of LLLT, a relapse was observed. LLLT was repeated (another four treatments) and restored the initial success. During the next 2 years, 17 additional treatments were performed on an "as needed" basis, to maintain the result. LLLT was shown to improve and maintain vision in a patient with RP, and may thereby have contributed to slowing down blindness.

  9. Key Informant Perceptions of Vision Loss in Children and ...

    African Journals Online (AJOL)

    tulyasys

    understand how vision can practically be assessed and how poor vision can affect a child, whether by limiting the ability to do activities of daily living or by limiting social interactions. In this group, there were some misconceptions regarding the use of color vision and the assessment of reading as a tool for vision assessment ...

  10. A Practical Solution Using A New Approach To Robot Vision

    Science.gov (United States)

    Hudson, David L.

    1984-01-01

    Up to now, robot vision systems have been designed to serve both application development and operational needs in inspection, assembly and material handling. This universal approach to robot vision is too costly for many practical applications. A new industrial vision system separates the function of application program development from on-line operation. A Vision Development System (VDS) is equipped with facilities designed to simplify and accelerate the application program development process. A complimentary but lower cost Target Application System (TASK) runs the application program developed with the VDS. This concept is presented in the context of an actual robot vision application that improves inspection and assembly for a manufacturer of electronic terminal keyboards. Applications developed with a VDS experience lower development cost when compared with conventional vision systems. Since the TASK processor is not burdened with development tools, it can be installed at a lower cost than comparable "universal" vision systems that are intended to be used for both development and on-line operation. The VDS/TASK approach opens more industrial applications to robot vision that previously were not practical because of the high cost of vision systems. Although robot vision is a new technology, it has been applied successfully to a variety of industrial needs in inspection, manufacturing, and material handling. New developments in robot vision technology are creating practical, cost effective solutions for a variety of industrial needs. A year or two ago, researchers and robot manufacturers interested in implementing a robot vision application could take one of two approaches. The first approach was to purchase all the necessary vision components from various sources. That meant buying an image processor from one company, a camera from another and lens and light sources from yet others. The user then had to assemble the pieces, and in most instances he had to write

  11. A Vision for the Future of Environmental Research: Creating Environmental Intelligence Centers

    Science.gov (United States)

    Barron, E. J.

    2002-12-01

    being in the context of global, national and regional stewardship. These societal needs lead to a vision that uses a regional framework as a stepping-stone to a comprehensive national or global capability. The development of a comprehensive regional framework depends on a new approach to environmental research - the creation of regional Environmental Intelligence Centers. A key objective is to bring a demanding level of discipline to "forecasting" in a broad arena of environmental issues. The regional vision described above is designed to address a broad range of current and future environmental issues by creating a capability based on integrating diverse observing systems, making data readily accessible, developing an increasingly comprehensive predictive capability at the spatial and temporal scales appropriate for examining societal issues, and creating a vigorous intersection with decision-makers. With demonstrated success over a few large-scale regions of the U.S., this strategy will very likely grow into a national capability that far exceeds current capabilities.

  12. Vision systems for scientific and engineering applications

    International Nuclear Information System (INIS)

    Chadda, V.K.

    2009-01-01

    Human performance can get degraded due to boredom, distraction and fatigue in vision-related tasks such as measurement, counting etc. Vision based techniques are increasingly being employed in many scientific and engineering applications. Notable advances in this field are emerging from continuing improvements in the fields of sensors and related technologies, and advances in computer hardware and software. Automation utilizing vision-based systems can perform repetitive tasks faster and more accurately, with greater consistency over time than humans. Electronics and Instrumentation Services Division has developed vision-based systems for several applications to perform tasks such as precision alignment, biometric access control, measurement, counting etc. This paper describes in brief four such applications. (author)

  13. Vision Screening

    Science.gov (United States)

    ... an efficient and cost-effective method to identify children with visual impairment or eye conditions that are likely to lead ... main goal of vision screening is to identify children who have or are at ... visual impairment unless treated in early childhood. Other problems that ...

  14. Embodied Visions

    DEFF Research Database (Denmark)

    Grodal, Torben Kragh

    Embodied Visions presents a groundbreaking analysis of film through the lens of bioculturalism, revealing how human biology as well as human culture determine how films are made and experienced. Throughout the book the author uses the breakthroughs of modern brain science to explain general featu...

  15. Long term clinical outcome of peripheral nerve stimulation in patients with chronic peripheral neuropathic pain

    DEFF Research Database (Denmark)

    Calenbergh, F. Van; Gybels, J.; Laere, K. Van

    2009-01-01

    BACKGROUND: Chronic neuropathic pain after injury to a peripheral nerve is known to be resistant to treatment. Peripheral nerve stimulation is one of the possible treatment options, which is, however, not performed frequently. In recent years we have witnessed a renewed interest for PNS. The aim...... of the present study was to evaluate the long-term clinical efficacy of PNS in a group of patients with peripheral neuropathic pain treated with PNS since the 1980s. METHODS: Of an original series of 11 patients, 5 patients could be invited for clinical examination, detailed assessment of clinical pain and QST...... functioning) also showed positive effects. Quantitative Sensory Testing results did not show significant differences in cold pain and heat pain thresholds between the "ON" and "OFF" conditions. CONCLUSION: In selected patients with peripheral neuropathic pain PNS remains effective even after more than 20...

  16. The Democratic Vision of Carl Schmitt

    DEFF Research Database (Denmark)

    Pedersen, Søren Hviid

    2013-01-01

    The main purpose of this paper is to justify two propositions. One, that Schmitt’s political vision is indeed democratic and second, that Schmitt’s democratic vision, plebiscitary or leadership democracy, is better adapted to our modern political condition and the challenges confronting modern...

  17. Functional Vision Observation. Technical Assistance Paper.

    Science.gov (United States)

    Florida State Dept. of Education, Tallahassee. Bureau of Education for Exceptional Students.

    Technical assistance is provided concerning documentation of functional vision loss for Florida students with visual impairments. The functional vision observation should obtain enough information for determination of special service eligibility. The observation is designed to supplement information on the medical eye examination, and is conducted…

  18. Models to enhance research capacity and capability in clinical nurses: a narrative review.

    Science.gov (United States)

    O'Byrne, Louise; Smith, Sheree

    2011-05-01

    To identify models used as local initiatives to build capability and capacity in clinical nurses. The National Health Service, Nursing and Midwifery Council and the United Kingdom Clinical Research Collaboration all support the development of the building of research capability and capacity in clinical nurses in the UK. Narrative review. A literature search of databases (including Medline and Pubmed) using the search terms nursing research, research capacity and research capability combined with building, development, model and collaboration. Publications which included a description or methodological study of a structured initiative to tackle research capacity and capability development in clinical nurses were selected. Three models were found to be dominant in the literature. These comprised evidence-based practice, facilitative and experiential learning models. Strong leadership, organisational need and support management were elements found in all three models. Methodological issues were evident and pertain to small sample sizes, inconsistent and poorly defined outcomes along with a lack of data. Whilst the vision of a research ready and active National Health Service is to be applauded to date, there appears to be limited research on the best approach to support local initiatives for nurses that build research capability and capacity. Future studies will need to focus on well-defined objectives and outcomes to enable robust evidence to support local initiatives. To build research capability and capacity in clinical nurses, there is a need to evaluate models and determine the best approach that will provide clinical nurses with research opportunities. © 2010 Blackwell Publishing Ltd.

  19. Telerehabilitation for people with low vision.

    Science.gov (United States)

    Bittner, Ava K; Wykstra, Stephanie L; Yoshinaga, Patrick D; Li, Tianjing

    2015-08-31

    Low vision affects over 300 million people worldwide and can compromise both activities of daily living and quality of life. Rehabilitative training and vision assistive equipment (VAE) may help, but some visually impaired people have limited resources to attend in-person visits at rehabilitation clinics. These people may be able to overcome barriers to care through remote, Internet-based consultation (i.e., telerehabilitation). To compare the effects of telerehabilitation with face-to-face (e.g., in-office or inpatient) vision rehabilitation services for improving vision-related quality of life and reading speed in people with visual function loss due to any ocular condition. Secondary objectives are to evaluate compliance with scheduled rehabilitation sessions, abandonment rates for visual assistive equipment devices, and patient satisfaction ratings. We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (2015 Issue 5), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1980 to June 2015), EMBASE (January 1980 to June 2015), PubMed (1980 to June 2015), ClinicalTrials.gov (www.clinicaltrials.gov) and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any language restriction or study design filter in the electronic searches; however, we restricted the searches from 1980 onwards because the Internet was not introduced to the public until 1982. We last searched the electronic databases on 15 June 2015. We planned to include randomized controlled trials (RCTs) or controlled clinical trials (CCTs) in which participants were diagnosed with low vision and were undergoing low vision rehabilitation using an Internet, web-based technology compared with an approach based on in-person consultations. Two authors independently screened titles and abstracts, and then full-text articles against

  20. Rebalancing binocular vision in amblyopia.

    Science.gov (United States)

    Ding, Jian; Levi, Dennis M

    2014-03-01

    Humans with amblyopia have an asymmetry in binocular vision: neural signals from the amblyopic eye are suppressed in the cortex by the fellow eye. The purpose of this study was to develop new models and methods for rebalancing this asymmetric binocular vision by manipulating the contrast and luminance in the two eyes. We measured the perceived phase of a cyclopean sinewave by asking normal and amblyopic observers to indicate the apparent location (phase) of the dark trough in the horizontal cyclopean sine wave relative to a black horizontal reference line, and used the same stimuli to measure perceived contrast by matching the binocular combined contrast to a standard contrast presented to one eye. We varied both the relative contrast and luminance of the two eyes' inputs, in order to rebalance the asymmetric binocular vision. Amblyopic binocular vision becomes more and more asymmetric the higher the stimulus contrast or spatial frequency. Reanalysing our previous data, we found that, at a given spatial frequency, the binocular asymmetry could be described by a log-linear formula with two parameters, one for the maximum asymmetry and one for the rate at which the binocular system becomes asymmetric as the contrast increases. Our new data demonstrates that reducing the dominant eye's mean luminance reduces its suppression of the non-dominant eye, and therefore rebalances the asymmetric binocular vision. While the binocular asymmetry in amblyopic vision can be rebalanced by manipulating the relative contrast or luminance of the two eyes at a given spatial frequency and contrast, it is very difficult or even impossible to rebalance the asymmetry for all visual conditions. Nonetheless, wearing a neutral density filter before the dominant eye (or increasing the mean luminance in the non-dominant eye) may be more beneficial than the traditional method of patching the dominant eye for treating amblyopia. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The

  1. Information Society Visions in the Nordic Countries

    DEFF Research Database (Denmark)

    Henten, Anders; Kristensen, Thomas Myrup

    2000-01-01

    This paper analyses the information society visions put forward by the governments/administrations of the Nordic countries and compares them to the visions advanced at the EU-level. The paper suggests that the information society visions constitute a kind of common ideology for almost the whole...... political spectrum although it is characterised by a high degree of neo-liberal thinking. It is further argued that there is no distinctly Nordic model for an information society....

  2. Reproducibility of an objective four-choice canine vision testing technique that assesses vision at differing light intensities.

    Science.gov (United States)

    Annear, Matthew J; Gornik, Kara R; Venturi, Francesca L; Hauptman, Joe G; Bartoe, Joshua T; Petersen-Jones, Simon M

    2013-09-01

    The increasing importance of canine retinal dystrophy models means accurate vision testing is needed. This study was performed to evaluate a four-choice vision testing technique for any difference in outcome measures with repeated evaluations of the same dogs.   Four 11-month-old RPE65-deficient dogs. Vision was evaluated using a previously described four-choice vision testing device. Four evaluations were performed at 2-week intervals. Vision was assessed at six different white light intensities (bright through dim), and each eye was evaluated separately. The ability to select the one of the four exit tunnels that was open at the far end was assessed ('choice of exit') and recorded as correct or incorrect first tunnel choice. 'Time to exit' the device was also recorded. Both outcomes were analyzed for significance using anova. We hypothesized that performance would improve with repeated testing (more correct choices and more rapid time to exit). 'Choice of exit' did not vary significantly between each evaluation (P = 0.12), in contrast 'time to exit' increased significantly (P = 0.012), and showed greater variability in dim light conditions. We found no evidence to support the hypothesis that either measure of outcome worsened with repeated testing; in fact, the 'time to exit' outcome worsened rather than improved. The 'choice of exit' gave consistent results between trials. These outcome data indicate the importance of including a choice-based assessment of vision in addition to measurement of device transit time. © 2012 American College of Veterinary Ophthalmologists.

  3. The secret world of shrimps: polarisation vision at its best.

    Directory of Open Access Journals (Sweden)

    Sonja Kleinlogel

    Full Text Available BACKGROUND: Animal vision spans a great range of complexity, with systems evolving to detect variations in light intensity, distribution, colour, and polarisation. Polarisation vision systems studied to date detect one to four channels of linear polarisation, combining them in opponent pairs to provide intensity-independent operation. Circular polarisation vision has never been seen, and is widely believed to play no part in animal vision. METHODOLOGY/PRINCIPAL FINDINGS: Polarisation is fully measured via Stokes' parameters--obtained by combined linear and circular polarisation measurements. Optimal polarisation vision is the ability to see Stokes' parameters: here we show that the crustacean Gonodactylus smithii measures the exact components required. CONCLUSIONS/SIGNIFICANCE: This vision provides optimal contrast-enhancement and precise determination of polarisation with no confusion states or neutral points--significant advantages. Linear and circular polarisation each give partial information about the polarisation of light--but the combination of the two, as we will show here, results in optimal polarisation vision. We suggest that linear and circular polarisation vision not be regarded as different modalities, since both are necessary for optimal polarisation vision; their combination renders polarisation vision independent of strongly linearly or circularly polarised features in the animal's environment.

  4. Fractured Visions

    DEFF Research Database (Denmark)

    Bonde, Inger Ellekilde

    2016-01-01

    In the post-war period a heterogeneous group of photographers articulate a new photographic approach to the city as motive in a photographic language that combines intense formalism with subjective vision. This paper analyses the photobook Fragments of a City published in 1960 by Danish photograp...

  5. Artificial intelligence and computer vision

    CERN Document Server

    Li, Yujie

    2017-01-01

    This edited book presents essential findings in the research fields of artificial intelligence and computer vision, with a primary focus on new research ideas and results for mathematical problems involved in computer vision systems. The book provides an international forum for researchers to summarize the most recent developments and ideas in the field, with a special emphasis on the technical and observational results obtained in the past few years.

  6. Pre-attentive and attentive vision module

    NARCIS (Netherlands)

    Nyamsuren, Enkhbold; Taatgen, Niels A.

    This paper introduces a new vision module, called PAAV, developed for the cognitive architecture ACT-R. Unlike ACT-R's default vision module that was originally developed for top-down perception only, PAAV was designed to model a wide range of tasks, such as visual search and scene viewing, where

  7. Normal and sonographic anatomy of selected peripheral nerves. Part III: Peripheral nerves of the lower limb.

    Science.gov (United States)

    Kowalska, Berta; Sudoł-Szopińska, Iwona

    2012-06-01

    The ultrasonographic examination is currently increasingly used in imaging peripheral nerves, serving to supplement the physical examination, electromyography and magnetic resonance imaging. As in the case of other USG imaging studies, the examination of peripheral nerves is non-invasive and well-tolerated by patients. The typical ultrasonographic picture of peripheral nerves as well as the examination technique have been discussed in part I of this article series, following the example of the median nerve. Part II of the series presented the normal anatomy and the technique for examining the peripheral nerves of the upper limb. This part of the article series focuses on the anatomy and technique for examining twelve normal peripheral nerves of the lower extremity: the iliohypogastric and ilioinguinal nerves, the lateral cutaneous nerve of the thigh, the pudendal, sciatic, tibial, sural, medial plantar, lateral plantar, common peroneal, deep peroneal and superficial peroneal nerves. It includes diagrams showing the proper positioning of the sonographic probe, plus USG images of the successively discussed nerves and their surrounding structures. The ultrasonographic appearance of the peripheral nerves in the lower limb is identical to the nerves in the upper limb. However, when imaging the lower extremity, convex probes are more often utilized, to capture deeply-seated nerves. The examination technique, similarly to that used in visualizing the nerves of upper extremity, consists of locating the nerve at a characteristic anatomic reference point and tracking it using the "elevator technique". All 3 parts of the article series should serve as an introduction to a discussion of peripheral nerve pathologies, which will be presented in subsequent issues of the "Journal of Ultrasonography".

  8. Visions of the Future of (Legal) Education

    OpenAIRE

    Madison, Michael

    2017-01-01

    One law professor takes a stab at imagining an ideal law school of the future and describing how to get there. The Essay spells out a specific possible vision, taking into account changes to the demand for legal services and changes to the economics and composition of the legal profession. That thought experiment leads to a series of observations about values and vision in legal education in general and about what it might take to move any vision forward.

  9. Optics, illumination, and image sensing for machine vision II

    International Nuclear Information System (INIS)

    Svetkoff, D.J.

    1987-01-01

    These proceedings collect papers on the general subject of machine vision. Topics include illumination and viewing systems, x-ray imaging, automatic SMT inspection with x-ray vision, and 3-D sensing for machine vision

  10. Treatment of painful diabetic peripheral neuropathy.

    Science.gov (United States)

    Rosenberg, Casandra J; Watson, James C

    2015-02-01

    Painful diabetic peripheral neuropathy impairs quality of life and can be difficult to treat. To discuss current treatment recommendations for painful diabetic peripheral neuropathy. Literature review. Systematic review of the literature discussing treatment of painful diabetic peripheral neuropathy. Existing treatment guidelines were studied and compared. Painful diabetic peripheral neuropathy occurs in about one in six people with diabetes. This condition impairs quality of life and increases healthcare costs. Treatment recommendations exist, but individual patient therapy can require a trial-and-error approach. Many treatment options have adjuvant benefits or side effects which should be considered prior to initiating therapy. Often, a combination of treatment modalities with various mechanisms of action is required for adequate pain control. Adequate medication titration and a reasonable trial period should be allowed. The treatment of painful diabetic peripheral neuropathy can be challenging, but effective management can improve patient's quality of life. Painful diabetic peripheral neuropathy impairs quality of life and can be difficult to treat. Many treatment options have adjuvant benefits or side effects which should be considered prior to initiating therapy. Often, a combination of treatment modalities with various mechanisms of action is required for adequate pain control. © The International Society for Prosthetics and Orthotics 2014.

  11. Teachers’ professional vision: exploring and clarifying the concept

    Directory of Open Access Journals (Sweden)

    Tomáš Janík

    2012-06-01

    Full Text Available This theoretical study introduces the concept of professional vision into Czech academic discourse as one of the potential concepts that can be used when contemplating (teacher professionalization. At the beginning the authors mention selected attempts to define characteristics of a profession and introduce their view of the issue of teacher professionality that is built on three dimensions – professional vision, professional knowledge and professional action. They further suggest the relationships among these dimensions in the model of pedagogical reasoning and action (Shulman, 1986 and the ALACT model of reflection (Korthagen, 2011.Professional vision in general and specifically in the teaching profession is discussedand its existing conceptualizations are described. Based on other theoretical and empirical studies connected to this issue, the authors then suggest their own approach to teachers’ professional vision. The relationship between professional vision and reflection on the spiral of pedagogical reasoning and action is elaborated on. In the end,the usability of the concept of professional vision in teacher education is discussed, specifically in the process of development of an e-learning (videoenvironment for(prospective teachers.

  12. Agrarian Visions.

    Science.gov (United States)

    Theobald, Paul

    A new feature in "Country Teacher,""Agrarian Visions" reminds rural teachers that they can do something about rural decline. Like to populism of the 1890s, the "new populism" advocates rural living. Current attempts to address rural decline are contrary to agrarianism because: (1) telecommunications experts seek to…

  13. Regional new energy vision for Aogaki town; Aogakicho chiiki shin energy vision

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-02-01

    A regional new energy vision has been formulated as part of Phase 4 of the Town Development Program of Aogaki town, Hyogo Prefecture, calling for 'building a town, comfortable to live in and full of hope, by utilizing rich natural environments.' The results of activities conducted in this connection are summarized in five chapters, which are (1) the description of the new energy vision, (2) Aogaki-town's energy characteristics, (3) basic plan, (4) driving forward of prioritized plans, and (5) toward the driving forward of the new energy vision. Chapter (4) comprises the goal of the formulation of the prioritized plans, the definition of the prioritized plans, and the establishment of individual projects. Established as the individual projects are the introduction of new energy linked to the inhibition of carbon dioxide gas emissions, use of wind energy for multiple purposes, public facilities preceding others in the introduction of new energy, building of environmentally symbiotic residences utilizing new energy, utilization of new energy at recreation facilities, and the popularization of and enlightening about new energy and its introduction through the participation of the local population. (NEDO)

  14. Computer vision based room interior design

    Science.gov (United States)

    Ahmad, Nasir; Hussain, Saddam; Ahmad, Kashif; Conci, Nicola

    2015-12-01

    This paper introduces a new application of computer vision. To the best of the author's knowledge, it is the first attempt to incorporate computer vision techniques into room interior designing. The computer vision based interior designing is achieved in two steps: object identification and color assignment. The image segmentation approach is used for the identification of the objects in the room and different color schemes are used for color assignment to these objects. The proposed approach is applied to simple as well as complex images from online sources. The proposed approach not only accelerated the process of interior designing but also made it very efficient by giving multiple alternatives.

  15. Causes of vision impairment and assessment of need for low vision services for students of blind schools in Nepal.

    Science.gov (United States)

    Kansakar, I; Thapa, H B; Salma, K C; Ganguly, S; Kandel, R P; Rajasekaran, S

    The present study is first of its kind to evaluate causes of visual impairment of blind students in Nepal and assess their need for low vision rehabilitation services. To evaluate causes of vision impairment of students enrolled in blind schools in Nepal and assess the need for low vision rehabilitation services in these students. A survey was conducted in 12 blind schools in Nepal, which were registered with Nepal Association for Welfare of Blindness (NAWB).It was conducted by a team of an ophthalmologist and an optometrist, by using standard eye examination protocols of the World Health Organization Prevention of Blindness Program (WHO/PBL). Of the 345 students enrolled in 12 schools, 285 students were examined (response rate of 82.61%). The students were in the 5 - 29 years age group. Nearly three-fourth of the children had become blind within one year of age and 52.3% visually impaired at birth and 20.7% developed vision impairment within one year of age. After refraction, 26 students (9.12%) had mild visual impairment, 21 students (7.37%) had severe visual impairment and 238 students (83.51%) were blind. The main cause of vision impairment was found to be corneal 35.79% and retina diseases, mainly dystrophy, 20.35% followed by problems with the whole globe, lens and optic nerve, accounting for 13.33%, 12.63% and 12.98% respectively. The major etiological factors were those of childhood such as Vitamin A deficiency, measles and similar causes (42.11%) followed by hereditary causes (25.26%). Of the total students examined, 48.07% were visually impaired due to preventable causes and 16.14% treatable aggregating to 64.21% of avoidable blindness. Fifty seven (28.22%) students could read smaller than 2 M print size after low vision assessment for near and 33(15.78%) students benefited with telescopic trial for distance low vision. In Nepal, renewed focus on providing best possible quality of life for visually impaired children by proper low vision assessment and eye

  16. Promoting peripheral myelin repair.

    Science.gov (United States)

    Zhou, Ye; Notterpek, Lucia

    2016-09-01

    Compared to the central nervous system (CNS), peripheral nerves have a remarkable ability to regenerate and remyelinate. This regenerative capacity to a large extent is dependent on and supported by Schwann cells, the myelin-forming glial cells of the peripheral nervous system (PNS). In a variety of paradigms, Schwann cells are critical in the removal of the degenerated tissue, which is followed by remyelination of newly-regenerated axons. This unique plasticity of Schwann cells has been the target of myelin repair strategies in acute injuries and chronic diseases, such as hereditary demyelinating neuropathies. In one approach, the endogenous regenerative capacity of Schwann cells is enhanced through interventions such as exercise, electrical stimulation or pharmacological means. Alternatively, Schwann cells derived from healthy nerves, or engineered from different tissue sources have been transplanted into the PNS to support remyelination. These transplant approaches can then be further enhanced by exercise and/or electrical stimulation, as well as by the inclusion of biomaterial engineered to support glial cell viability and neurite extension. Advances in our basic understanding of peripheral nerve biology, as well as biomaterial engineering, will further improve the functional repair of myelinated peripheral nerves. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Family Functioning and Low Vision: A Systematic Review

    Science.gov (United States)

    Bambara, Jennifer K.; Wadley, Virginia; Owsley, Cynthia; Martin, Roy C.; Porter, Chebon; Dreer, Laura E.

    2009-01-01

    This review highlights the literature on the function and adjustment process of family members of persons with adult-onset vision loss. The majority of the literature has focused on the unique role that the family plays in providing both instrumental and emotional support to adults with low vision. In contrast, the impact of low vision on the…

  18. Peripheral neuropathy in HIV: prevalence and risk factors

    Science.gov (United States)

    Evans, Scott R.; Ellis, Ronald J.; Chen, Huichao; Yeh, Tzu-min; Lee, Anthony J.; Schifitto, Giovanni; Wu, Kunling; Bosch, Ronald J.; McArthur, Justin C.; Simpson, David M.; Clifford, David B.

    2011-01-01

    Objectives To estimate neuropathic sign/symptom rates with initiation of combination antiretroviral therapy (cART) in HIV-infected ART-naive patients, and to investigate risk factors for: peripheral neuropathy and symptomatic peripheral neuropathy (SPN), recovery from peripheral neuropathy/SPN after neurotoxic ART (nART) discontinuation, and the absence of peripheral neuropathy/SPN while on nART. Design AIDS Clinical Trials Group (ACTG) Longitudinal Linked Randomized Trial participants who initiated cART in randomized trials for ART-naive patients were annually screened for symptoms/signs of peripheral neuropathy. ART use and disease characteristics were collected longitudinally. Methods Peripheral neuropathy was defined as at least mild loss of vibration sensation in both great toes or absent/hypoactive ankle reflexes bilaterally. SPN was defined as peripheral neuropathy and bilateral symptoms. Generalized estimating equation logistic regression was used to estimate associations. Results Two thousand, one hundred and forty-one participants were followed from January 2000 to June 2007. Rates of peripheral neuropathy/SPN at 3 years were 32.1/8.6% despite 87.1% with HIV-1RNA 400 copies/ml or less and 70.3% with CD4 greater than 350 cells/µl. Associations with higher odds of peripheral neuropathy included older patient age and current nART use. Associations with higher odds of SPN included older patient age, nART use, and history of diabetes mellitus. Associations with lower odds of recovery after nART discontinuation included older patient age. Associations with higher odds of peripheral neuropathy while on nART included older patient age and current protease inhibitor use. Associations with higher odds of SPN while on nART included older patient age, history of diabetes, taller height, and protease inhibitor use. Conclusion Signs of peripheral neuropathy remain despite virologic/immunologic control but frequently occurs without symptoms. Aging is a risk factor for

  19. Front-end vision and multi-scale image analysis multi-scale computer vision theory and applications, written in Mathematica

    CERN Document Server

    Romeny, Bart M Haar

    2008-01-01

    Front-End Vision and Multi-Scale Image Analysis is a tutorial in multi-scale methods for computer vision and image processing. It builds on the cross fertilization between human visual perception and multi-scale computer vision (`scale-space') theory and applications. The multi-scale strategies recognized in the first stages of the human visual system are carefully examined, and taken as inspiration for the many geometric methods discussed. All chapters are written in Mathematica, a spectacular high-level language for symbolic and numerical manipulations. The book presents a new and effective

  20. Vision and the hypothalamus.

    Science.gov (United States)

    Trachtman, Joseph N

    2010-02-01

    For nearly 2 millennia, signs of hypothalamic-related vision disorders have been noticed as illustrated by paintings and drawings of that time of undiagnosed Horner's syndrome. It was not until the 1800s, however, that specific connections between the hypothalamus and the vision system were discovered. With a fuller elaboration of the autonomic nervous system in the early to mid 1900s, many more pathways were discovered. The more recently discovered retinohypothalamic tracts show the extent and influence of light stimulation on hypothalamic function and bodily processes. The hypothalamus maintains its myriad connections via neural pathways, such as with the pituitary and pineal glands; the chemical messengers of the peptides, cytokines, and neurotransmitters; and the nitric oxide mechanism. As a result of these connections, the hypothalamus has involvement in many degenerative diseases. A complete feedback mechanism between the eye and hypothalamus is established by the retinohypothalamic tracts and the ciliary nerves innervating the anterior pole of the eye and the retina. A discussion of hypothalamic-related vision disorders includes neurologic syndromes, the lacrimal system, the retina, and ocular inflammation. Tables and figures have been used to aid in the explanation of the many connections and chemicals controlled by the hypothalamus. The understanding of the functions of the hypothalamus will allow the clinician to gain better insight into the many pathologies associated between the vision system and the hypothalamus. In the future, it may be possible that some ocular disease treatments will be via direct action on hypothalamic function. Copyright 2010 American Optometric Association. Published by Elsevier Inc. All rights reserved.

  1. Challenges to micro-financing PLWHA clients in Rwanda : a study based on vision finance, a world vision mico-finance institution, Kigali Branch

    NARCIS (Netherlands)

    Muyinda, B.

    2008-01-01

    The study was conducted on Vision Finance a microfinance institution of World Vision in Rwanda. The major research question focussed on determining the factors that have contributed default on loans disbursed to PLWHA clients by Vision Finance. Results show that chronic illness and death disrupt

  2. Peripheral Vestibular System Disease in Vestibular Schwannomas

    DEFF Research Database (Denmark)

    Møller, Martin Nue; Hansen, Søren; Caye-Thomasen, Per

    2015-01-01

    density of the peripheral vestibular nerve branches, and atrophy of the neuroepithelium of the vestibular end organs. In cases with small tumors, peripheral disease occurred only in the tissue structures innervated by the specific nerve from which the tumor originated. CONCLUSION: Vestibular schwannomas...... are associated with distinctive disease of the peripheral vestibular tissue structures, suggesting anterograde degeneration and that dizziness in these patients may be caused by deficient peripheral vestibular nerve fibers, neurons, and end organs. In smaller tumors, a highly localized disease occurs, which...

  3. Coevolution of coloration and colour vision?

    Science.gov (United States)

    Lind, Olle; Henze, Miriam J; Kelber, Almut; Osorio, Daniel

    2017-07-05

    The evolutionary relationship between signals and animal senses has broad significance, with potential consequences for speciation, and for the efficacy and honesty of biological communication. Here we outline current understanding of the diversity of colour vision in two contrasting groups: the phylogenetically conservative birds, and the more variable butterflies. Evidence for coevolution of colour signals and vision exists in both groups, but is limited to observations of phenotypic differences between visual systems, which might be correlated with coloration. Here, to illustrate how one might interpret the evolutionary significance of such differences, we used colour vision modelling based on an avian eye to evaluate the effects of variation in three key characters: photoreceptor spectral sensitivity, oil droplet pigmentation and the proportions of different photoreceptor types. The models predict that physiologically realistic changes in any one character will have little effect, but complementary shifts in all three can substantially affect discriminability of three types of natural spectra. These observations about the adaptive landscape of colour vision may help to explain the general conservatism of photoreceptor spectral sensitivities in birds. This approach can be extended to other types of eye and spectra to inform future work on coevolution of coloration and colour vision.This article is part of the themed issue 'Animal coloration: production, perception, function and application'. © 2017 The Author(s).

  4. Night vision: changing the way we drive

    Science.gov (United States)

    Klapper, Stuart H.; Kyle, Robert J. S.; Nicklin, Robert L.; Kormos, Alexander L.

    2001-03-01

    A revolutionary new Night Vision System has been designed to help drivers see well beyond their headlights. From luxury automobiles to heavy trucks, Night Vision is helping drivers see better, see further, and react sooner. This paper describes how Night Vision Systems are being used in transportation and their viability for the future. It describes recent improvements to the system currently in the second year of production. It also addresses consumer education and awareness, cost reduction, product reliability, market expansion and future improvements.

  5. Vision servo of industrial robot: A review

    Science.gov (United States)

    Zhang, Yujin

    2018-04-01

    Robot technology has been implemented to various areas of production and life. With the continuous development of robot applications, requirements of the robot are also getting higher and higher. In order to get better perception of the robots, vision sensors have been widely used in industrial robots. In this paper, application directions of industrial robots are reviewed. The development, classification and application of robot vision servo technology are discussed, and the development prospect of industrial robot vision servo technology is proposed.

  6. [Acquired disorders of color vision].

    Science.gov (United States)

    Lascu, Lidia; Balaş, Mihaela

    2002-01-01

    This article is a general view of acquired disorders of color vision. The revision of the best known methods and of the etiopathogenic classification is not very important in ophthalmology but on the other hand, the detection of the blue defect advertise and associated ocular pathology. There is a major interest in serious diseases as multiple sclerosis, AIDS, diabetes melitus, when the first ocular sign can be a defect in the color vision.

  7. Structural Capability of an Organization toward Innovation Capability

    DEFF Research Database (Denmark)

    Nielsen, Susanne Balslev; Momeni, Mostafa

    2016-01-01

    The scholars in the field of strategic management have developed two major approaches for attainment of competitive advantage: an approach based on environmental opportunities, and another one based on internal capabilities of an organization. Some investigations in the last two decades have...... indicated that the advantages relying on the internal capabilities of organizations may determine the competitive position of organizations better than environmental opportunities do. Characteristics of firms shows that one of the most internal capabilities that lead the organizations to the strongest...... competitive advantage in the organizations is the innovation capability. The innovation capability is associated with other organizational capabilities, and many organizations have focused on the need to identify innovation capabilities.This research focuses on recognition of the structural aspect...

  8. Predicting Visual Disability in Glaucoma With Combinations of Vision Measures.

    Science.gov (United States)

    Lin, Stephanie; Mihailovic, Aleksandra; West, Sheila K; Johnson, Chris A; Friedman, David S; Kong, Xiangrong; Ramulu, Pradeep Y

    2018-04-01

    We characterized vision in glaucoma using seven visual measures, with the goals of determining the dimensionality of vision, and how many and which visual measures best model activity limitation. We analyzed cross-sectional data from 150 older adults with glaucoma, collecting seven visual measures: integrated visual field (VF) sensitivity, visual acuity, contrast sensitivity (CS), area under the log CS function, color vision, stereoacuity, and visual acuity with noise. Principal component analysis was used to examine the dimensionality of vision. Multivariable regression models using one, two, or three vision tests (and nonvisual predictors) were compared to determine which was best associated with Rasch-analyzed Glaucoma Quality of Life-15 (GQL-15) person measure scores. The participants had a mean age of 70.2 and IVF sensitivity of 26.6 dB, suggesting mild-to-moderate glaucoma. All seven vision measures loaded similarly onto the first principal component (eigenvectors, 0.220-0.442), which explained 56.9% of the variance in vision scores. In models for GQL scores, the maximum adjusted- R 2 values obtained were 0.263, 0.296, and 0.301 when using one, two, and three vision tests in the models, respectively, though several models in each category had similar adjusted- R 2 values. All three of the best-performing models contained CS. Vision in glaucoma is a multidimensional construct that can be described by several variably-correlated vision measures. Measuring more than two vision tests does not substantially improve models for activity limitation. A sufficient description of disability in glaucoma can be obtained using one to two vision tests, especially VF and CS.

  9. Mission statements and vision documents in medical practices.

    Science.gov (United States)

    Drury, Ivo; Slomski, Carol

    2006-01-01

    Thoughtful, carefully constructed mission statements and vision documents serve both to signal the purpose of a medical practice to the public and other professional colleagues, and to keep the practice's providers focused on its key purposes. Practice culture is the primary driver ofmission and vision. We clarify the differences between mission statements and vision documents, and offer guidelines to aid in constructing them.

  10. Aerospace Concurrent Engineering Design Teams: Current State, Next Steps and a Vision for the Future

    Science.gov (United States)

    Hihn, Jairus; Chattopadhyay, Debarati; Karpati, Gabriel; McGuire, Melissa; Borden, Chester; Panek, John; Warfield, Keith

    2011-01-01

    Over the past sixteen years, government aerospace agencies and aerospace industry have developed and evolved operational concurrent design teams to create novel spaceflight mission concepts and designs. These capabilities and teams, however, have evolved largely independently. In today's environment of increasingly complex missions with limited budgets it is becoming readily apparent that both implementing organizations and today's concurrent engineering teams will need to interact more often than they have in the past. This will require significant changes in the current state of practice. This paper documents the findings from a concurrent engineering workshop held in August 2010 to identify the key near term improvement areas for concurrent engineering capabilities and challenges to the long-term advancement of concurrent engineering practice. The paper concludes with a discussion of a proposed vision for the evolution of these teams over the next decade.

  11. Vision of a cyberinfrastructure for nonnative, invasive species management

    Science.gov (United States)

    2008-01-01

    Although the quantity of data on the location, status, and management of invasive species is ever increasing, invasive species data sets are often difficult to obtain and integrate. A cyberinfrastructure for such information could make these data available for Internet users. The data can be used to create regional watch lists, to send e-mail alerts when a new species enters a region, to construct models of species' current and future distributions, and to inform management. Although the exchange of environmental data over the Internet in the form of raster data is maturing, and the exchange of species occurrence data is developing quickly, there is room for improvement. In this article, we present a vision for a comprehensive invasive species cyberinfrastructure that is capable of accessing data effectively, creating models of invasive species spread, and distributing this information.

  12. Hypothyroidism: Can It Cause Peripheral Neuropathy?

    Science.gov (United States)

    Hypothyroidism: Can it cause peripheral neuropathy? Can hypothyroidism cause peripheral neuropathy and, if so, how is it treated? Answers from Todd B. Nippoldt, M.D. Hypothyroidism — a condition in which your ...

  13. Peripheral ameloblastic fibro-odontoma or peripheral developing complex odontoma: report of a case

    DEFF Research Database (Denmark)

    Reibel, Jesper; Grønbæk, Anni Birgitte; Poulsen, Sven

    2011-01-01

    BACKGROUND. Peripheral (extraosseous) odontogenic tumors are rare. CASE REPORT. This report describes a case which illustrates the clinical and histopathological features of a lesion in an 8-year-old, healthy Caucasian girl that on purely morphological grounds would seem to be an ameloblastic fibro-odontoma......, but may represent a case of a peripheral developing complex odontoma. CONCLUSION. Conservative surgical enucleation of the lesion was followed by unbcomplicated healing and no recurrence was seen....

  14. Parallel inputs to memory in bee colour vision.

    Science.gov (United States)

    Horridge, Adrian

    2016-03-01

    In the 19(th) century, it was found that attraction of bees to light was controlled by light intensity irrespective of colour, and a few critical entomologists inferred that vision of bees foraging on flowers was unlike human colour vision. Therefore, quite justly, Professor Carl von Hess concluded in his book on the Comparative Physiology of Vision (1912) that bees do not distinguish colours in the way that humans enjoy. Immediately, Karl von Frisch, an assistant in the Zoology Department of the same University of Münich, set to work to show that indeed bees have colour vision like humans, thereby initiating a new research tradition, and setting off a decade of controversy that ended only at the death of Hess in 1923. Until 1939, several researchers continued the tradition of trying to untangle the mechanism of bee vision by repeatedly testing trained bees, but made little progress, partly because von Frisch and his legacy dominated the scene. The theory of trichromatic colour vision further developed after three types of receptors sensitive to green, blue, and ultraviolet (UV), were demonstrated in 1964 in the bee. Then, until the end of the century, all data was interpreted in terms of trichromatic colour space. Anomalies were nothing new, but eventually after 1996 they led to the discovery that bees have a previously unknown type of colour vision based on a monochromatic measure and distribution of blue and measures of modulation in green and blue receptor pathways. Meanwhile, in the 20(th) century, search for a suitable rationalization, and explorations of sterile culs-de-sac had filled the literature of bee colour vision, but were based on the wrong theory.

  15. 78 FR 62935 - Qualification of Drivers; Exemption Applications; Vision

    Science.gov (United States)

    2013-10-22

    ..., his optometrist noted, ``Mr. Smith, despite having a prosthetic left eye, has fully functional vision...-0166] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces receipt of applications from 26 individuals for exemption from the vision requirement in the...

  16. 75 FR 1453 - Qualification of Drivers; Exemption Renewals; Vision

    Science.gov (United States)

    2010-01-11

    ...; Exemption Renewals; Vision AGENCY: Federal Motor Carrier Safety Administration (FMCSA), DOT. ACTION: Notice... the vision requirement in the Federal Motor Carrier Safety Regulations for 23 individuals. FMCSA has statutory authority to exempt individuals from the vision requirement if the exemptions granted will not...

  17. Promoting peripheral myelin repair

    OpenAIRE

    Zhou, Ye; Notterpek, Lucia

    2016-01-01

    Compared to the central nervous system (CNS), peripheral nerves have a remarkable ability to regenerate and remyelinate. This regenerative capacity to a large extent is dependent on and supported by Schwann cells, the myelin-forming glial cells of the peripheral nervous system (PNS). In a variety of paradigms, Schwann cells are critical in the removal of the degenerated tissue, which is followed by remyelination of newly-regenerated axons. This unique plasticity of Schwann cells has been the ...

  18. Hypnosis-associated blue-tinted vision: a case report

    Directory of Open Access Journals (Sweden)

    Savedoff Aaron D

    2005-12-01

    Full Text Available Abstract Background Self-hypnosis has been taught routinely at the SUNY Upstate Medical University for treatment of pulmonary symptoms thought to be amenable to psychological therapy. While using hypnosis for relaxation, four individuals, including a patient with cystic fibrosis, reported development of blue-tinted vision. Based on a search of the literature, we believe this is the first published report of hypnosis-associated blue-tinted vision. Case presentation The patient reported blue-tinted vision when he used hypnosis on an almost daily basis for seven years. The visual change typically occurred when he was relaxed. Moreover, a concurrent erection in the absence of sexual thoughts usually was present. The other three individuals reported blue-tinted vision after learning how to use hypnosis for relaxation as part of a group hypnosis instruction. Conclusion The blue-tinted vision experienced by the individuals in this report may be the result of an hypnosis-induced primary change in cognitive processing. Additionally, as the relaxing effect of hypnosis can be associated with a reduction in blood pressure and increased blood flow, hypnosis-associated blue-tinted vision also may be related to retinal vasodilation.

  19. Individual vision and peak distribution in collective actions

    Science.gov (United States)

    Lu, Peng

    2017-06-01

    People make decisions on whether they should participate as participants or not as free riders in collective actions with heterogeneous visions. Besides of the utility heterogeneity and cost heterogeneity, this work includes and investigates the effect of vision heterogeneity by constructing a decision model, i.e. the revised peak model of participants. In this model, potential participants make decisions under the joint influence of utility, cost, and vision heterogeneities. The outcomes of simulations indicate that vision heterogeneity reduces the values of peaks, and the relative variance of peaks is stable. Under normal distributions of vision heterogeneity and other factors, the peaks of participants are normally distributed as well. Therefore, it is necessary to predict distribution traits of peaks based on distribution traits of related factors such as vision heterogeneity and so on. We predict the distribution of peaks with parameters of both mean and standard deviation, which provides the confident intervals and robust predictions of peaks. Besides, we validate the peak model of via the Yuyuan Incident, a real case in China (2014), and the model works well in explaining the dynamics and predicting the peak of real case.

  20. Vision Systems with the Human in the Loop

    Science.gov (United States)

    Bauckhage, Christian; Hanheide, Marc; Wrede, Sebastian; Käster, Thomas; Pfeiffer, Michael; Sagerer, Gerhard

    2005-12-01

    The emerging cognitive vision paradigm deals with vision systems that apply machine learning and automatic reasoning in order to learn from what they perceive. Cognitive vision systems can rate the relevance and consistency of newly acquired knowledge, they can adapt to their environment and thus will exhibit high robustness. This contribution presents vision systems that aim at flexibility and robustness. One is tailored for content-based image retrieval, the others are cognitive vision systems that constitute prototypes of visual active memories which evaluate, gather, and integrate contextual knowledge for visual analysis. All three systems are designed to interact with human users. After we will have discussed adaptive content-based image retrieval and object and action recognition in an office environment, the issue of assessing cognitive systems will be raised. Experiences from psychologically evaluated human-machine interactions will be reported and the promising potential of psychologically-based usability experiments will be stressed.

  1. Peripheral cemento-ossifying fibroma of maxilla.

    Science.gov (United States)

    Chatterjee, Anirban; Ajmera, Neha; Singh, Amit

    2010-07-01

    Peripheral cemento-ossifying fibroma is a reactive gingival overgrowth occurring frequently in anterior maxilla. It is a slow-growing benign tumor which may lead to pathologic migration and other periodontal problems, so it should be excised as soon as possible. The recurrence rate of peripheral cemento-ossifying fibroma is reported to be 8% to 20%, so a close postoperative follow-up is required. Herein, we are reporting a similar case of peripheral cemento-ossifying fibroma in the maxillary anterior region.

  2. Altered joint moment strategy during stair walking in diabetes patients with and without peripheral neuropathy.

    Science.gov (United States)

    Brown, Steven J; Handsaker, Joseph C; Maganaris, Constantinos N; Bowling, Frank L; Boulton, Andrew J M; Reeves, Neil D

    2016-05-01

    To investigate lower limb biomechanical strategy during stair walking in patients with diabetes and patients with diabetic peripheral neuropathy, a population known to exhibit lower limb muscular weakness. The peak lower limb joint moments of twenty-two patients with diabetic peripheral neuropathy and thirty-nine patients with diabetes and no neuropathy were compared during ascent and descent of a staircase to thirty-two healthy controls. Fifty-nine of the ninety-four participants also performed assessment of their maximum isokinetic ankle and knee joint moment (muscle strength) to assess the level of peak joint moments during the stair task relative to their maximal joint moment-generating capabilities (operating strengths). Both patient groups ascended and descended stairs slower than controls (pperipheral neuropathy were lower (pperipheral neuropathy compared to controls, and lower at knee only in patients without neuropathy. Operating strengths were higher (pneuropathy during stair descent compared to the controls, but not during stair ascent. Patients with diabetic peripheral neuropathy walk slower to alter gait strategy during stair walking and account for lower-limb muscular weakness, but still exhibit heightened operating strengths during stair descent, which may impact upon fatigue and the ability to recover a safe stance following postural instability. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  3. Specifying colours for colour vision testing using computer graphics.

    Science.gov (United States)

    Toufeeq, A

    2004-10-01

    This paper describes a novel test of colour vision using a standard personal computer, which is simple and reliable to perform. Twenty healthy individuals with normal colour vision and 10 healthy individuals with a red/green colour defect were tested binocularly at 13 selected points in the CIE (Commission International d'Eclairage, 1931) chromaticity triangle, representing the gamut of a computer monitor, where the x, y coordinates of the primary colour phosphors were known. The mean results from individuals with normal colour vision were compared to those with defective colour vision. Of the 13 points tested, five demonstrated consistently high sensitivity in detecting colour defects. The test may provide a convenient method for classifying colour vision abnormalities.

  4. Perioperative Vision Loss in Cervical Spinal Surgery.

    Science.gov (United States)

    Gabel, Brandon C; Lam, Arthur; Chapman, Jens R; Oskouian, Rod J; Nassr, Ahmad; Currier, Bradford L; Sebastian, Arjun S; Arnold, Paul M; Hamilton, Steven R; Fehlings, Michael G; Mroz, Thomas E; Riew, K Daniel

    2017-04-01

    Retrospective multicenter case series. To assess the rate of perioperative vision loss following cervical spinal surgery. Medical records for 17 625 patients from 21 high-volume surgical centers from the AOSpine North America Clinical Research Network who received cervical spine surgery (levels from C2 to C7) between January 1, 2005, and December 31, 2011, inclusive, were reviewed to identify occurrences of vision loss following surgery. Of the 17 625 patients in the registry, there were 13 946 patients assessed for the complication of blindness. There were 9591 cases that involved only anterior surgical approaches; the remaining 4355 cases were posterior and/or circumferential fusions. There were no cases of blindness or vision loss in the postoperative period reported during the sampling period. Perioperative vision loss following cervical spinal surgery is exceedingly rare.

  5. Dense range map reconstruction from a versatile robotic sensor system with an active trinocular vision and a passive binocular vision.

    Science.gov (United States)

    Kim, Min Young; Lee, Hyunkee; Cho, Hyungsuck

    2008-04-10

    One major research issue associated with 3D perception by robotic systems is the creation of efficient sensor systems that can generate dense range maps reliably. A visual sensor system for robotic applications is developed that is inherently equipped with two types of sensor, an active trinocular vision and a passive stereo vision. Unlike in conventional active vision systems that use a large number of images with variations of projected patterns for dense range map acquisition or from conventional passive vision systems that work well on specific environments with sufficient feature information, a cooperative bidirectional sensor fusion method for this visual sensor system enables us to acquire a reliable dense range map using active and passive information simultaneously. The fusion algorithms are composed of two parts, one in which the passive stereo vision helps active vision and the other in which the active trinocular vision helps the passive one. The first part matches the laser patterns in stereo laser images with the help of intensity images; the second part utilizes an information fusion technique using the dynamic programming method in which image regions between laser patterns are matched pixel-by-pixel with help of the fusion results obtained in the first part. To determine how the proposed sensor system and fusion algorithms can work in real applications, the sensor system is implemented on a robotic system, and the proposed algorithms are applied. A series of experimental tests is performed for a variety of configurations of robot and environments. The performance of the sensor system is discussed in detail.

  6. Object recognition in images by human vision and computer vision

    NARCIS (Netherlands)

    Chen, Q.; Dijkstra, J.; Vries, de B.

    2010-01-01

    Object recognition plays a major role in human behaviour research in the built environment. Computer based object recognition techniques using images as input are challenging, but not an adequate representation of human vision. This paper reports on the differences in object shape recognition

  7. Early Cognitive Vision as a Frontend for Cognitive Systems

    DEFF Research Database (Denmark)

    Krüger, Norbert; Pugeault, Nicolas; Baseski, Emre

    We discuss the need of an elaborated in-between stage bridging early vision and cognitive vision which we call `Early Cognitive Vision' (ECV). This stage provides semantically rich, disambiguated and largely task independent scene representations which can be used in many contexts. In addition...

  8. 75 FR 60862 - Qualification of Drivers; Exemption Renewals; Vision

    Science.gov (United States)

    2010-10-01

    ...-2006-24015; FMCA- 2008-0106; FMCSA-2008-0174] Qualification of Drivers; Exemption Renewals; Vision.... SUMMARY: FMCSA previously announced its decision to renew the exemptions from the vision requirement in... exempt individuals from the vision requirement if the exemptions granted will not compromise safety. The...

  9. 78 FR 1919 - Qualification of Drivers; Exemption Applications; Vision

    Science.gov (United States)

    2013-01-09

    ...-0339] Qualification of Drivers; Exemption Applications; Vision AGENCY: Federal Motor Carrier Safety... announces receipt of applications from 14 individuals for exemption from the vision requirement in the Federal Motor Carrier Safety Regulations. They are unable to meet the vision requirement in one eye for...

  10. REDUCTIONS WITHOUT REGRET: DEFINING THE NEEDED CAPABILITIES

    Energy Technology Data Exchange (ETDEWEB)

    Swegle, J.; Tincher, D.

    2013-09-10

    This is the second of three papers (in addition to an introductory summary) aimed at providing a framework for evaluating future reductions or modifications of the U.S. nuclear force, first by considering previous instances in which nuclear-force capabilities were eliminated; second by looking forward into at least the foreseeable future at the features of global and regional deterrence (recognizing that new weapon systems currently projected will have expected lifetimes stretching beyond our ability to predict the future); and third by providing examples of past or possible undesirable outcomes in the shaping of the future nuclear force, as well as some closing thoughts for the future. This paper begins with a discussion of the current nuclear force and the plans and procurement programs for the modernization of that force. Current weapon systems and warheads were conceived and built decades ago, and procurement programs have begun for the modernization or replacement of major elements of the nuclear force: the heavy bomber, the air-launched cruise missile, the ICBMs, and the ballistic-missile submarines. In addition, the Nuclear Weapons Council has approved a new framework for nuclear-warhead life extension not fully fleshed out yet that aims to reduce the current number of nuclear explosives from seven to five, the so-called 3+2 vision. This vision includes three interoperable warheads for both ICBMs and SLBMs (thus eliminating one backup weapon) and two warheads for aircraft delivery (one gravity bomb and one cruise-missile, eliminating a second backup gravity bomb). This paper also includes a discussion of the current and near-term nuclear-deterrence mission, both global and regional, and offers some observations on future of the strategic deterrence mission and the challenges of regional and extended nuclear deterrence.

  11. Real-time Vision using FPGAs, GPUs and Multi-core CPUs

    DEFF Research Database (Denmark)

    Kjær-Nielsen, Anders

    the introduction and evolution of a wide variety of powerful hardware architectures have made the developed theory more applicable in performance demanding and real-time applications. Three different architectures have dominated the field due to their parallel capabilities that are often desired when dealing...... processors in the vision community. The introduction of programming languages like CUDA from NVIDIA has made it easier to utilize the high parallel processing powers of the GPU for general purpose computing and thereby realistic to use based on the effort involved with development. The increased clock...... frequencies and number of Configurable Logic Blocks (CLBs) of the FPGAs, as well as the introduction of dedicated hardware implementations like multipliers, Digital Signal Processing (DSP) slices and even embedded hard-core CPU implementations have made them more applicable for general purpose computing...

  12. Cultured embryonic non-innervated mouse muzzle is capable of generating a whisker pattern.

    Science.gov (United States)

    Andrés, F L; Van Der Loos, H

    1983-01-01

    The whisker pattern on the muzzle of the mouse is mapped in the contralateral parietal neocortex, each whisker follicle projecting to its own multineuronal unit ('barrel'). To determine the role, if any, of the peripheral innervation in the establishment of the vibrissal array, we cultured non-innervated prospective whiskerpads from 9- and 10-day-old embryos, mostly on chorioallantoic membrane. The results show that skin, alone, is capable of generating the whisker pattern, thus adducing a strong argument for the hypothesis that the central brain maps have their origin in the periphery. Copyright © 1983. Published by Elsevier Ltd.

  13. [Ultrasound-guided peripheral catheterization].

    Science.gov (United States)

    Salleras-Duran, Laia; Fuentes-Pumarola, Concepció

    2016-01-01

    Peripheral catheterization is a technique that can be difficult in some patients. Some studies have recently described the use of ultrasound to guide the venous catheterization. To describe the success rate, time required, complications of ultrasound-guided peripheral venous catheterization. and patients and professionals satisfaction The search was performed in databases (Medline-PubMed, Cochrane Library, CINAHL and Cuiden Plus) for studies published about ultrasound-guided peripheral venous catheterization performed on patients that provided results on the success of the technique, complications, time used, patient satisfaction and the type of professional who performed the technique. A total of 21 studies were included. Most of them get a higher success rate 80% in the catheterization ecoguide and time it is not higher than the traditional technique. The Technical complications analyzed were arterial puncture rates and lower nerve 10%. In all studies measuring and comparing patient satisfaction in the art ecoguide is greater. Various professional groups perform the technique. The use of ultrasound for peripheral pipes has a high success rate, complications are rare and the time used is similar to that of the traditional technique. The technique of inserting catheters through ultrasound may be learned by any professional group performing venipuncture. Finally, it gets underscores the high patient satisfaction with the use of this technique. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  14. Normal and sonographic anatomy of selected peripheral nerves. Part III: Peripheral nerves of the lower limb

    Directory of Open Access Journals (Sweden)

    Berta Kowalska

    2012-06-01

    Full Text Available The ultrasonographic examination is currently increasingly used in imaging peripheral nerves, serving to supplement the physical examination, electromyography and magnetic resonance imaging. As in the case of other USG imaging studies, the examination of peripheral nerves is non-invasive and well-tolerated by patients. The typical ultrasonographic picture of peripheral nerves as well as the examination technique have been discussed in part I of this article series, following the example of the median nerve. Part II of the series presented the normal anatomy and the technique for examining the peripheral nerves of the upper limb. This part of the article series focuses on the anatomy and technique for examining twelve normal peripheral nerves of the lower extremity: the iliohypogastric and ilioinguinal nerves, the lateral cutaneous nerve of the thigh, the pudendal, sciatic, tibial, sural, medial plantar, lateral plantar, common peroneal, deep peroneal and superficial peroneal nerves. It includes diagrams showing the proper positioning of the sonographic probe, plus USG images of the successively discussed nerves and their surrounding structures. The ultrasonographic appearance of the peripheral nerves in the lower limb is identical to the nerves in the upper limb. However, when imaging the lower extremity, convex probes are more often utilized, to capture deeply-seated nerves. The examination technique, similarly to that used in visualizing the nerves of upper extremity, consists of locating the nerve at a characteristic anatomic reference point and tracking it using the “elevator technique”. All 3 parts of the article series should serve as an introduction to a discussion of peripheral nerve pathologies, which will be presented in subsequent issues of the “Journal of Ultrasonography”.

  15. Delusion and bi-ocular vision.

    Science.gov (United States)

    De Masi, Franco

    2015-10-01

    The delusional experience is the result of a grave disjunction in the psyche whose outcome is not readily predictable. Examination of the specific mode of disjunction may help us understand the nature and radical character of delusion. I will present the therapy of a psychotic patient who after many years of analysis and progresses in his life continues to show delusional episodes although limited and contained. In his case, the two visions, one delusional and the other real, remain distinct and differentiated from each other because they both possess the same perceptual character, that of reality. He has a bi-ocular vision of reality and not a binocular one because his vision lacks integration, as would necessarily be the case if the two visions could be compared with each other. The principle of non-contradiction ceases to apply in delusion. A corollary of the failure of the principle of non-contradiction is that, if a statement and its negation are both true, then any statement is true. Logicians call this consequence the principle of explosion. For this reason, the distinction between truth, reality, improbability, probability, possibility and impossibility is lost in the delusional system, thus triggering an omnipotent, explosive mechanism with a potentially infinite progression. The paper presents some thoughts for a possible analytic transformation of the delusional experience. Copyright © 2015 Institute of Psychoanalysis.

  16. Computer vision and machine learning for archaeology

    NARCIS (Netherlands)

    van der Maaten, L.J.P.; Boon, P.; Lange, G.; Paijmans, J.J.; Postma, E.

    2006-01-01

    Until now, computer vision and machine learning techniques barely contributed to the archaeological domain. The use of these techniques can support archaeologists in their assessment and classification of archaeological finds. The paper illustrates the use of computer vision techniques for

  17. 2020 Vision for Tank Waste Cleanup (One System Integration) - 12506

    Energy Technology Data Exchange (ETDEWEB)

    Harp, Benton; Charboneau, Stacy; Olds, Erik [US DOE (United States)

    2012-07-01

    The mission of the Department of Energy's Office of River Protection (ORP) is to safely retrieve and treat the 56 million gallons of Hanford's tank waste and close the Tank Farms to protect the Columbia River. The millions of gallons of waste are a by-product of decades of plutonium production. After irradiated fuel rods were taken from the nuclear reactors to the processing facilities at Hanford they were exposed to a series of chemicals designed to dissolve away the rod, which enabled workers to retrieve the plutonium. Once those chemicals were exposed to the fuel rods they became radioactive and extremely hot. They also couldn't be used in this process more than once. Because the chemicals are caustic and extremely hazardous to humans and the environment, underground storage tanks were built to hold these chemicals until a more permanent solution could be found. The Cleanup of Hanford's 56 million gallons of radioactive and chemical waste stored in 177 large underground tanks represents the Department's largest and most complex environmental remediation project. Sixty percent by volume of the nation's high-level radioactive waste is stored in the underground tanks grouped into 18 'tank farms' on Hanford's central plateau. Hanford's mission to safely remove, treat and dispose of this waste includes the construction of a first-of-its-kind Waste Treatment Plant (WTP), ongoing retrieval of waste from single-shell tanks, and building or upgrading the waste feed delivery infrastructure that will deliver the waste to and support operations of the WTP beginning in 2019. Our discussion of the 2020 Vision for Hanford tank waste cleanup will address the significant progress made to date and ongoing activities to manage the operations of the tank farms and WTP as a single system capable of retrieving, delivering, treating and disposing Hanford's tank waste. The initiation of hot operations and subsequent full operations

  18. Low Vision Enhancement System

    Science.gov (United States)

    1995-01-01

    NASA's Technology Transfer Office at Stennis Space Center worked with the Johns Hopkins Wilmer Eye Institute in Baltimore, Md., to incorporate NASA software originally developed by NASA to process satellite images into the Low Vision Enhancement System (LVES). The LVES, referred to as 'ELVIS' by its users, is a portable image processing system that could make it possible to improve a person's vision by enhancing and altering images to compensate for impaired eyesight. The system consists of two orientation cameras, a zoom camera, and a video projection system. The headset and hand-held control weigh about two pounds each. Pictured is Jacob Webb, the first Mississippian to use the LVES.

  19. Robotics, vision and control fundamental algorithms in Matlab

    CERN Document Server

    Corke, Peter

    2017-01-01

    Robotic vision, the combination of robotics and computer vision, involves the application of computer algorithms to data acquired from sensors. The research community has developed a large body of such algorithms but for a newcomer to the field this can be quite daunting. For over 20 years the author has maintained two open-source MATLAB® Toolboxes, one for robotics and one for vision. They provide implementations of many important algorithms and allow users to work with real problems, not just trivial examples. This book makes the fundamental algorithms of robotics, vision and control accessible to all. It weaves together theory, algorithms and examples in a narrative that covers robotics and computer vision separately and together. Using the latest versions of the Toolboxes the author shows how complex problems can be decomposed and solved using just a few simple lines of code. The topics covered are guided by real problems observed by the author over many years as a practitioner of both robotics and compu...

  20. Computer Vision and Image Processing: A Paper Review

    Directory of Open Access Journals (Sweden)

    victor - wiley

    2018-02-01

    Full Text Available Computer vision has been studied from many persective. It expands from raw data recording into techniques and ideas combining digital image processing, pattern recognition, machine learning and computer graphics. The wide usage has attracted many scholars to integrate with many disciplines and fields. This paper provide a survey of the recent technologies and theoretical concept explaining the development of computer vision especially related to image processing using different areas of their field application. Computer vision helps scholars to analyze images and video to obtain necessary information,    understand information on events or descriptions, and scenic pattern. It used method of multi-range application domain with massive data analysis. This paper provides contribution of recent development on reviews related to computer vision, image processing, and their related studies. We categorized the computer vision mainstream into four group e.g., image processing, object recognition, and machine learning. We also provide brief explanation on the up-to-date information about the techniques and their performance.