WorldWideScience

Sample records for peripheral surface mount

  1. How Many Peripheral Solder Joints in a Surface Mounted Design Experience Inelastic Strains?

    Science.gov (United States)

    Suhir, E.; Yi, S.; Ghaffarian, R.

    2017-03-01

    It has been established that it is the peripheral solder joints that are the most vulnerable in the ball-grid-array (BGA) and column-grid-array (CGA) designs and most often fail. As far as the long-term reliability of a soldered microelectronics assembly as a whole is concerned, it makes a difference, if just one or more peripheral joints experience inelastic strains. It is clear that the low cycle fatigue lifetime of the solder system is inversely proportional to the number of joints that simultaneously experience inelastic strains. A simple and physically meaningful analytical expression (formula) is obtained for the prediction, at the design stage, of the number of such joints, if any, for the given effective thermal expansion (contraction) mismatch of the package and PCB; materials and geometrical characteristics of the package/PCB assembly; package size; and, of course, the level of the yield stress in the solder material. The suggested formula can be used to determine if the inelastic strains in the solder material could be avoided by the proper selection of the above characteristics and, if not, how many peripheral joints are expected to simultaneously experience inelastic strains. The general concept is illustrated by a numerical example carried out for a typical BGA package. The suggested analytical model (formula) is applicable to any soldered microelectronics assembly. The roles of other important factors, such as, e.g., solder material anisotropy, grain size, and their random orientation within a joint, are viewed in this analysis as less important factors than the level of the interfacial stress. The roles of these factors will be accounted for in future work and considered, in addition to the location of the joint, in a more complicated, more sophisticated, and more comprehensive reliability/fatigue model.

  2. Robotized Surface Mounting of Permanent Magnets

    Directory of Open Access Journals (Sweden)

    Erik Hultman

    2014-10-01

    Full Text Available Using permanent magnets on a rotor can both simplify the design and increase the efficiency of electric machines compared to using electromagnets. A drawback, however, is the lack of existing automated assembly methods for large machines. This paper presents and motivates a method for robotized surface mounting of permanent magnets on electric machine rotors. The translator of the Uppsala University Wave Energy Converter generator is used as an example of a rotor. The robot cell layout, equipment design and assembly process are presented and validated through computer simulations and experiments with prototype equipment. A comparison with manual assembly indicates substantial cost savings and an improved work environment. By using the flexibility of industrial robots and a scalable equipment design, it is possible for this assembly method to be adjusted for other rotor geometries and sizes. Finally, there is a discussion on the work that remains to be done on improving and integrating the robot cell into a production line.

  3. A Surface-Mounted Rotor State Sensing System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — A surface-mounted instrumentation system for measuring rotor blade motions on rotorcraft, for use both in flight and in wind tunnel testing, is proposed for...

  4. PECULIARITIES OF ASSIGNMENT OF ROLLING BEARING MOUNTING AND PARAMETERS OF GEOMETRIC ACCURACY OF MOUNTING SURFACES OF SHAFTS AND FRAMES

    Directory of Open Access Journals (Sweden)

    Adamenko Yu. І.

    2017-04-01

    Full Text Available The standards and methods concerning assignment of rolling bearing fit with shafts and frames via example of bearing 6-208 are analyzed. We set certain differences of recommendations according to GOST 3325-85, "Rolling bearings. Tolerance zones and technical requirements to mounting surfaces of shafts and frames. Attachment" and by reference of rolling bearing manufacturers. The following factors should be taken into consideration when assigning the mounting with the tension the internal ring of the bearing with shaft and mounting with a gap in the outer ring with a housing bore. The methods of achieving accuracy of mounting surfaces of shafts and frames via form tolerance assignment: roundness tolerance, profile of longitudinal cut, cross section, cylindricity and others. It is possible to limit the bearing rings in different ways, for example appointing the cylindrical mounting surfaces and bead end surfaces the appropriate tolerances, namely: coaxiality tolerance or full radial beat of mounting surfaces, and also perpendicularity tolerance, butt beats and full butt beats of mounting end surfaces. We suggest to expand methods of achieving the accuracy of shafts and frames depending on seriation of production and production operations metrology support.

  5. PV module mounting method and mounting assembly

    Science.gov (United States)

    Lenox, Carl J.S.; Johnson, Kurt M.

    2013-04-23

    A method for mounting PV modules to a deck includes selecting PV module layout pattern so that adjacent PV module edges are spaced apart. PV mounting and support assemblies are secured to the deck according to the layout pattern using fasteners extending into the deck. The PV modules are placed on the PV mounting and support assemblies. Retaining elements are located over and secured against the upper peripheral edge surfaces of the PV modules so to secure them to the deck with the peripheral edges of the PV modules spaced apart from the deck. In some examples a PV module mounting assembly, for use on a shingled deck, comprises flashing, a base mountable on the flashing, a deck-penetrating fastener engageable with the base and securable to the deck so to secure the flashing and the base to the shingled deck, and PV module mounting hardware securable to the base.

  6. Performance characteristics of solar air heater with surface mounted obstacles

    International Nuclear Information System (INIS)

    Bekele, Adisu; Mishra, Manish; Dutta, Sushanta

    2014-01-01

    Highlights: • Solar air heater with delta shaped obstacles have been studied. • Obstacle angle of incidence strongly affects the thermo-hydraulic performance. • Thermal performance of obstacle mounted collectors is superior to smooth collectors. • Thermo-hydraulic performance of the present SAH is higher than those in previous studies. - Abstract: The performance of conventional solar air heaters (SAHs) can be improved by providing obstacles on the heated wall (i.e. on the absorber plate). Experiments have been performed to collect heat transfer and flow-friction data from an air heater duct with delta-shaped obstacles mounted on the absorber surface and having an aspect ratio 6:1 resembling the conditions close to the solar air heaters. This study encompassed for the range of Reynolds number (Re) from 2100 to 30,000, relative obstacle height (e/H) from 0.25 to 0.75, relative obstacle longitudinal pitch (P l /e) from 3/2 to 11/2, relative obstacle transverse pitch (P t /b) from 1 to 7/3 and the angle of incidence (α) varied from 30° to 90°. The thermo-hydraulic performance characteristics of SAH have been compared with the previous published works and the optimum range of the geometries have been explored for the better performance of such air-heaters compared to the other designs of solar air heaters

  7. Body surface mounted biomedical monitoring system using Bluetooth.

    Science.gov (United States)

    Nambu, Masayuki

    2007-01-01

    Continuous monitoring in daily life is important for the health condition control of the elderly. However, portable or wearable devices need to carry by user on their own will. On the other hand, implantation sensors are not adoptable, because of generic users dislike to insert the any object in the body for monitoring. Therefore, another monitoring system of the health condition to carry it easily is necessary. In addition, ID system is necessary even if the subject live with few families. Furthermore, every measurement system should be wireless system, because not to obstruct the daily life of the user. In this paper, we propose the monitoring system, which is mounted on the body surface. This system will not obstruct the action or behavior of user in daily life, because this system attached the body surface on the back of the user. In addition, this system has wireless communication system, using Bluetooth, and acquired data transfer to the outside of the house via the Internet.

  8. Hall Current Plasma Source Having a Center-Mounted or a Surface-Mounted Cathode

    Science.gov (United States)

    Martinez, Rafael A. (Inventor); Williams, John D. (Inventor); Moritz, Jr., Joel A. (Inventor); Farnell, Casey C. (Inventor)

    2018-01-01

    A miniature Hall current plasma source apparatus having magnetic shielding of the walls from ionized plasma, an integrated discharge channel and gas distributor, an instant-start hollow cathode mounted to the plasma source, and an externally mounted keeper, is described. The apparatus offers advantages over other Hall current plasma sources having similar power levels, including: lower mass, longer lifetime, lower part count including fewer power supplies, and the ability to be continuously adjustable to lower average power levels using pulsed operation and adjustment of the pulse duty cycle. The Hall current plasma source can provide propulsion for small spacecraft that either do not have sufficient power to accommodate a propulsion system or do not have available volume to incorporate the larger propulsion systems currently available. The present low-power Hall current plasma source can be used to provide energetic ions to assist the deposition of thin films in plasma processing applications.

  9. Wakes behind surface-mounted obstacles: Impact of aspect ratio, incident angle, and surface roughness

    Science.gov (United States)

    Tobin, Nicolas; Chamorro, Leonardo P.

    2018-03-01

    The so-called wake-moment coefficient C˜h and lateral wake deflection of three-dimensional windbreaks are explored in the near and far wake. Wind-tunnel experiments were performed to study the functional dependence of C˜h with windbreak aspect ratio, incidence angle, and the ratio of the windbreak height and surface roughness (h /z0 ). Supported with the data, we also propose basic models for the wake deflection of the windbreak in the near and far fields. The near-wake model is based on momentum conservation considering the drag on the windbreak, whereas the far-wake counterpart is based on existing models for wakes behind surface-mounted obstacles. Results show that C˜h does not change with windbreak aspect ratios of 10 or greater; however, it may be lower for an aspect ratio of 5. C˜h is found to change roughly with the cosine of the incidence angle, and to depend strongly on h /z0 . The data broadly support the proposed wake-deflection models, though better predictions could be made with improved knowledge of the windbreak drag coefficient.

  10. Multiple-Objective Particle Swarm Optimization for Multi-Head Beam-Type Surface Mounting Machines

    NARCIS (Netherlands)

    Torabi, S.A.; Hamedi, M.; Ashayeri, J.

    2010-01-01

    The growing demand for electronic devices has made the manufacturing of printed circuit boards (PCBs) a promising industry over the last decades. As the demand for printed circuit boards increases, the industry becomes more dependent on highly automated assembly processes using Surface Mounting

  11. Design and production of a new surface mount charge-integrating amplifier for CDF

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, C.; Drake, G.

    1991-12-31

    We present our experiences in designing and producing 26,000 new charge-integrating amplifiers for CDF, using surface-mount components. The new amplifiers were needed to instrument 920 new 24-channel CDF RABBIT boards, which are replacing an older design rendered obsolete by increases in the collision rate. Important design considerations were frequency response, physical size and cost. 5 refs.

  12. Design and production of a new surface mount charge-integrating amplifier for CDF

    International Nuclear Information System (INIS)

    Nelson, C.; Drake, G.

    1991-01-01

    We present our experiences in designing and producing 26,000 new charge-integrating amplifiers for CDF, using surface-mount components. The new amplifiers were needed to instrument 920 new 24-channel CDF RABBIT boards, which are replacing an older design rendered obsolete by increases in the collision rate. Important design considerations were frequency response, physical size and cost. 5 refs

  13. DNS of Turbulent Flow and Heat Transfer in a Channel with Surface Mounted Cubes

    NARCIS (Netherlands)

    Verstappen, R.W.C.P.; Velde, R.M. van der; Veldman, A.E.P.

    2000-01-01

    The turbulent flow and heat transfer in a channel with surface mounted cubical obstacles forms a generic example of a problem that occurs in many engineering applications, for instance in the design of cooling devices. We have performed a numerical simulation of it without using any turbulence

  14. DNS of turbulent flow and heat transfer in a channel with surface mounted cubes

    NARCIS (Netherlands)

    Verstappen, R.W.C.P.; Velde, R.M. van der; Veldman, A.E.P.

    2000-01-01

    The turbulent flow and heat transfer in a channel with surface mounted cubical obstacles forms a generic example of a problem that occurs in many engineering applications, for instance in the design of cooling devices. We have performed a numerical simulation of it without using any turbulence

  15. Surface topography characterization using an atomic force microscope mounted on a coordinate measuring machine

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Hansen, H.N; Kofod, N

    1999-01-01

    The paper describes the construction, testing and use of an integrated system for topographic characterization of fine surfaces on parts having relatively big dimensions. An atomic force microscope (AFM) was mounted on a manual three-coordinate measuring machine (CMM) achieving free positioning o...

  16. The impact of accelerometer mounting methods on the level of vibrations recorded at ground surface

    Directory of Open Access Journals (Sweden)

    Krzysztof Czech

    2014-08-01

    Full Text Available The paper presents the results of field research based on the measurements of accelerations recorded at ground surface. The source of the vibration characterized by high repetition rate of pulse parameters was light falling weight deflectometer ZFG-01. Measurements of vibrations have been carried out using top quality high-precision measuring system produced by Brüel&Kiær. Accelerometers were mounted on a sandy soil surface at the measuring points located radially at 5-m and 10-m distances from the source of vibration. The paper analyses the impact that the method of mounting accelerometers on the ground has on the level of the recorded values of accelerations of vibrations. It has been shown that the method of attaching the sensor to the surface of the ground is crucial for the credibility of the performed measurements.[b]Keywords[/b]: geotechnics, surface vibrations, ground, vibration measurement

  17. 2D Analytical Modeling of Magnetic Vector Potential in Surface Mounted and Surface Inset Permanent Magnet Machines

    Directory of Open Access Journals (Sweden)

    A. Jabbari

    2017-12-01

    Full Text Available A 2D analytical method for magnetic vector potential calculation in inner rotor surface mounted and surface inset permanent magnet machines considering slotting effects, magnetization orientation and winding layout has been proposed in this paper. The analytical method is based on the resolution of Laplace and Poisson equations as well as Maxwell equation in quasi- Cartesian coordinate by using sub-domain method and hyperbolic functions. The developed method is applied on the performance computation of two prototypes surface mounted permanent magnet motors and two prototypes surface inset permanent magnet motors. A radial and a parallel magnetization orientation is considered for each type of motor. The results of these models are validated through FEM method.

  18. Assembling surface mounted components on ink-jet printed double sided paper circuit board

    International Nuclear Information System (INIS)

    Andersson, Henrik A; Manuilskiy, Anatoliy; Haller, Stefan; Sidén, Johan; Nilsson, Hans-Erik; Hummelgård, Magnus; Olin, Håkan; Hummelgård, Christine

    2014-01-01

    Printed electronics is a rapidly developing field where many components can already be manufactured on flexible substrates by printing or by other high speed manufacturing methods. However, the functionality of even the most inexpensive microcontroller or other integrated circuit is, at the present time and for the foreseeable future, out of reach by means of fully printed components. Therefore, it is of interest to investigate hybrid printed electronics, where regular electrical components are mounted on flexible substrates to achieve high functionality at a low cost. Moreover, the use of paper as a substrate for printed electronics is of growing interest because it is an environmentally friendly and renewable material and is, additionally, the main material used for many packages in which electronics functionalities could be integrated. One of the challenges for such hybrid printed electronics is the mounting of the components and the interconnection between layers on flexible substrates with printed conductive tracks that should provide as low a resistance as possible while still being able to be used in a high speed manufacturing process. In this article, several conductive adhesives are evaluated as well as soldering for mounting surface mounted components on a paper circuit board with ink-jet printed tracks and, in addition, a double sided Arduino compatible circuit board is manufactured and programmed. (paper)

  19. Assembling surface mounted components on ink-jet printed double sided paper circuit board.

    Science.gov (United States)

    Andersson, Henrik A; Manuilskiy, Anatoliy; Haller, Stefan; Hummelgård, Magnus; Sidén, Johan; Hummelgård, Christine; Olin, Håkan; Nilsson, Hans-Erik

    2014-03-07

    Printed electronics is a rapidly developing field where many components can already be manufactured on flexible substrates by printing or by other high speed manufacturing methods. However, the functionality of even the most inexpensive microcontroller or other integrated circuit is, at the present time and for the foreseeable future, out of reach by means of fully printed components. Therefore, it is of interest to investigate hybrid printed electronics, where regular electrical components are mounted on flexible substrates to achieve high functionality at a low cost. Moreover, the use of paper as a substrate for printed electronics is of growing interest because it is an environmentally friendly and renewable material and is, additionally, the main material used for many packages in which electronics functionalities could be integrated. One of the challenges for such hybrid printed electronics is the mounting of the components and the interconnection between layers on flexible substrates with printed conductive tracks that should provide as low a resistance as possible while still being able to be used in a high speed manufacturing process. In this article, several conductive adhesives are evaluated as well as soldering for mounting surface mounted components on a paper circuit board with ink-jet printed tracks and, in addition, a double sided Arduino compatible circuit board is manufactured and programmed.

  20. Assembling surface mounted components on ink-jet printed double sided paper circuit board

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, Henrik A; Manuilskiy, Anatoliy; Haller, Stefan; Sidén, Johan; Nilsson, Hans-Erik [Department of Electronics Design, Mid Sweden University, SE-851 70 Sundsvall (Sweden); Hummelgård, Magnus; Olin, Håkan [Department of Natural Science, Mid Sweden University, SE-851 70 Sundsvall (Sweden); Hummelgård, Christine [Acreo Swedish ICT AB, Håstaholmen 4, SE-824 42 Hudiksvall (Sweden)

    2014-03-07

    Printed electronics is a rapidly developing field where many components can already be manufactured on flexible substrates by printing or by other high speed manufacturing methods. However, the functionality of even the most inexpensive microcontroller or other integrated circuit is, at the present time and for the foreseeable future, out of reach by means of fully printed components. Therefore, it is of interest to investigate hybrid printed electronics, where regular electrical components are mounted on flexible substrates to achieve high functionality at a low cost. Moreover, the use of paper as a substrate for printed electronics is of growing interest because it is an environmentally friendly and renewable material and is, additionally, the main material used for many packages in which electronics functionalities could be integrated. One of the challenges for such hybrid printed electronics is the mounting of the components and the interconnection between layers on flexible substrates with printed conductive tracks that should provide as low a resistance as possible while still being able to be used in a high speed manufacturing process. In this article, several conductive adhesives are evaluated as well as soldering for mounting surface mounted components on a paper circuit board with ink-jet printed tracks and, in addition, a double sided Arduino compatible circuit board is manufactured and programmed. (paper)

  1. Effect of 60Co γ-ray irradiation on cytoskeleton of human peripheral blood monocytes with whole mount cell electron microscopy in vitro

    International Nuclear Information System (INIS)

    Chen Xiaomei; Guo Yuhua; Yin Zhiwei

    1992-01-01

    Whole mount cell electron microscopy was used in combination with selective extraction to prepare cytoskeletal framework. Cytoskeleton prepared by Triton X-100 treatment of human peripheral blood monocytes appeared on electron microscopy as a highly organized and interconnected three-dimensional matrix of different fibrous elements. By three-dimensional visualization of Triton X-100 resistant cytoskeletons it was demonstrated that different doses of 60 Co γ-rays caused distinctive and reproducible alterations of the cytoskeleton of intact human peripheral blood monocytes in vitro. The alterations were similar to those caused by cytochalasin B and by colchicine. From these observations and other workers'studies, it is presumed that 60 Co γ-ray irradiation may inhibit cytoplasmic microtubule and microfilament assembling

  2. Tactile detection of slip: surface microgeometry and peripheral neural codes.

    Science.gov (United States)

    Srinivasan, M A; Whitehouse, J M; LaMotte, R H

    1990-06-01

    1. The role of the microgeometry of planar surfaces in the detection of sliding of the surfaces on human and monkey fingerpads was investigated. By the use of a servo-controlled tactile stimulator to press and stroke glass plates on passive fingerpads of human subjects, the ability of humans to discriminate the direction of skin stretch caused by friction and to detect the sliding motion (slip) of the plates with or without micrometer-sized surface features was determined. To identify the associated peripheral neural codes, evoked responses to the same stimuli were recorded from single, low-threshold mechanoreceptive afferent fibers innervating the fingerpads of anesthetized macaque monkeys. 2. Humans could not detect the slip of a smooth glass plate on the fingerpad. However, the direction of skin stretch was perceived based on the information conveyed by the slowly adapting afferents that respond differentially to the stretch directions. Whereas the direction of skin stretch signaled the direction of impending slip, the perception of relative motion between the plate and the finger required the existence of detectable surface features. 3. Barely detectable micrometer-sized protrusions on smooth surfaces led to the detection of slip of these surfaces, because of the exclusive activation of rapidly adapting fibers of either the Meissner (RA) or the Pacinian (PC) type to specific geometries of the microfeatures. The motion of a smooth plate with a very small single raised dot (4 microns high, 550 microns diam) caused the sequential activation of neighboring RAs along the dot path, thus providing a reliable spatiotemporal code. The stroking of the plate with a fine homogeneous texture composed of a matrix of dots (1 microns high, 50 microns diam, and spaced at 100 microns center-to-center) induced vibrations in the fingerpad that activated only the PCs and resulted in an intensive code. 4. The results show that surprisingly small features on smooth surfaces are

  3. Electrodeposition of WO3 nanoparticles into surface mounted metal-organic framework HKUST-1 thin films

    Science.gov (United States)

    Yoo, Hyeonseok; Welle, Alexander; Guo, Wei; Choi, Jinsub; Redel, Engelbert

    2017-03-01

    We describe a novel procedure to fabricate WO3@surface-mounted metal-organic framework (SURMOF) hybrid materials by electrodeposition of WO3 nanoparticles into HKUST-1, also termed Cu3(BTC)2 SURMOFs. These materials have been characterized using x-ray diffraction, time-of-flight secondary ion mass spectrometry, scanning electron microscopy, x-ray photoelectron spectroscopy as well as linear sweep voltammetry. The WO3 semiconductor/SURMOF heterostructures were further tested as hybrid electrodes in their performance for hydrogen evolution reaction from water.

  4. Vibration attenuation and shape control of surface mounted, embedded smart beam

    Directory of Open Access Journals (Sweden)

    Vivek Rathi

    Full Text Available Active Vibration Control (AVC using smart structure is used to reduce the vibration of a system by automatic modification of the system structural response. AVC is widely used, because of its wide and broad frequency response range, low additional mass, high adaptability and good efficiency. A lot of research has been done on Finite Element (FE models for AVC based on Euler Bernoulli Beam Theory (EBT. In the present work Timoshenko Beam Theory (TBT is used to model a smart cantilever beam with surface mounted sensors / actuators. A Periodic Output Feedback (POF Controller has been designed and applied to control the first three modes of vibration of a flexible smart cantilever beam. The difficulties encountered in the usage of surface mounted piezoelectric patches in practical situations can be overcome by the use of embedded shear sensors / actuators. A mathematical model of a smart cantilever beam with embedded shear sensors and actuators is developed. A POF Controller has been designed and applied to control of vibration of a flexible smart cantilever beam and effect of actuator location on the performance of the controller is investigated. The mathematical modeling and control of a Multiple Input multiple Output (MIMO systems with two sensors and two actuators have also been considered.

  5. Fourier decomposition of segmented magnets with radial magnetization in surface-mounted PM machines

    Science.gov (United States)

    Tiang, Tow Leong; Ishak, Dahaman; Lim, Chee Peng

    2017-11-01

    This paper presents a generic field model of radial magnetization (RM) pattern produced by multiple segmented magnets per rotor pole in surface-mounted permanent magnet (PM) machines. The magnetization vectors from either odd- or even-number of magnet blocks per pole are described. Fourier decomposition is first employed to derive the field model, and later integrated with the exact 2D analytical subdomain method to predict the magnetic field distributions and other motor global quantities. For the assessment purpose, a 12-slot/8-pole surface-mounted PM motor with two segmented magnets per pole is investigated by using the proposed field model. The electromagnetic performances of the PM machines are intensively predicted by the proposed magnet field model which include the magnetic field distributions, airgap flux density, phase back-EMF, cogging torque, and output torque during either open-circuit or on-load operating conditions. The analytical results are evaluated and compared with those obtained from both 2D and 3D finite element analyses (FEA) where an excellent agreement has been achieved.

  6. Bi2O3 nanoparticles encapsulated in surface mounted metal-organic framework thin films

    Science.gov (United States)

    Guo, Wei; Chen, Zhi; Yang, Chengwu; Neumann, Tobias; Kübel, Christian; Wenzel, Wolfgang; Welle, Alexander; Pfleging, Wilhelm; Shekhah, Osama; Wöll, Christof; Redel, Engelbert

    2016-03-01

    We describe a novel procedure to fabricate a recyclable hybrid-photocatalyst based on Bi2O3@HKUST-1 MOF porous thin films. Bi2O3 nanoparticles (NPs) were synthesized within HKUST-1 (or Cu3(BTC)2) surface-mounted metal-organic frame-works (SURMOFs) and characterized using X-ray diffraction (XRD), a quartz crystal microbalance (QCM) and transmission electron microscopy (TEM). The Bi2O3 semiconductor NPs (diameter 1-3 nm)/SURMOF heterostructures exhibit superior photo-efficiencies compared to NPs synthesized using conventional routes, as demonstrated via the photodegradation of the nuclear fast red (NFR) dye.We describe a novel procedure to fabricate a recyclable hybrid-photocatalyst based on Bi2O3@HKUST-1 MOF porous thin films. Bi2O3 nanoparticles (NPs) were synthesized within HKUST-1 (or Cu3(BTC)2) surface-mounted metal-organic frame-works (SURMOFs) and characterized using X-ray diffraction (XRD), a quartz crystal microbalance (QCM) and transmission electron microscopy (TEM). The Bi2O3 semiconductor NPs (diameter 1-3 nm)/SURMOF heterostructures exhibit superior photo-efficiencies compared to NPs synthesized using conventional routes, as demonstrated via the photodegradation of the nuclear fast red (NFR) dye. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr00532b

  7. The metallurgical approach on the solder voids behaviour in surface mount devices

    International Nuclear Information System (INIS)

    Mohabattul Zaman Bukhari

    1996-01-01

    Solder voids are believed to cause poor heat dissiption in the Surface Mount devices and reduce the reliability of the devices at higher operating services. There are a lot of factors involved in creating voids such as gas/flux entrapment, wettability, outgasseous, air bubbles in the solder paste, inconsistency of solder coverage and improper metal scheme selection. This study was done to observe the behaviour of the solder voids in term of flux entrapmentt and wettability. It is believed that flux entrapment and wettability are verify this hypothesis. Two types of metal scheme were chosen which are Nickel (Ni) plated and Tin (Sn) plated heatsink. X-ray techniques such as Radiographic Inspection Analysis and EDAX were used to detect the minute solder voids. The solder voids observed on the heatsinks and Copper shims after the reflow process are believed to be a non contact voids that resulted from some portion of the surface not wetting properly

  8. Classification of surface types using SIR-C/X-SAR, Mount Everest Area, Tibet

    Science.gov (United States)

    Albright, Thomas P.; Painter, Thomas H.; Roberts, Dar A.; Shi, Jiancheng; Dozier, Jeff; Fielding, Eric

    1998-01-01

    Imaging radar is a promising tool for mapping snow and ice cover in alpine regions. It combines a high-resolution, day or night, all-weather imaging capability with sensitivity to hydrologic and climatic snow and ice parameters. We use the spaceborne imaging radar-C/X-band synthetic aperture radar (SIR-C/X-SAR) to map snow and glacial ice on the rugged north slope of Mount Everest. From interferometrically derived digital elevation data, we compute the terrain calibration factor and cosine of the local illumination angle. We then process and terrain-correct radar data sets acquired on April 16, 1994. In addition to the spectral data, we include surface slope to improve discrimination among several surface types. These data sets are then used in a decision tree to generate an image classification. This method is successful in identifying and mapping scree/talus, dry snow, dry snow-covered glacier, wet snow-covered glacier, and rock-covered glacier, as corroborated by comparison with existing surface cover maps and other ancillary information. Application of the classification scheme to data acquired on October 7 of the same year yields accurate results for most surface types but underreports the extent of dry snow cover.

  9. Initial rotor position estimation and sliding preventing for elevators with surface-mounted PMSMs

    Science.gov (United States)

    Liu, Feng; Shen, Anwen; Tang, Qipeng; Xu, Jinbang

    2016-03-01

    Improved methods of initial rotor position estimation and sliding prevention are presented in this paper for elevators with surface-mounted permanent magnet synchronous machines (SPMSMs). In contrast to most of the existing literature, in this paper, estimation errors caused by stator resistance and dead time are analysed in detail. The improved estimation method can reduce the errors greatly without dead-time compensations and knowledge of motor parameters. Besides, an observer-based feedforward compensation of load torque is introduced to elevator applications to prevent sliding during the starting process. Since the torque observer is widely used in other motor applications, we focus on the impact caused by the change in inertia. Finally, a series of experiments are performed on a testing system with two 13.4 kW SPMSMs and drivers to illustrate the effectiveness and improvement of the method.

  10. Determination of the High Frequency Inductance Profile of Surface Mounted Permanent Magnet Synchronous Motors

    DEFF Research Database (Denmark)

    Lu, Kaiyuan; Rasmussen, Peter Omand; Ritchie, Ewen

    2008-01-01

    ) synchronous motors. This paper presents an AC+DC measurement method for determination of the d-axis and q-axis high frequency inductance profiles of SMPM synchronous motors. This method uses DC currents to set a desired magnetic working point on the motor laminations, and then superimpose balanced small AC......Accurate knowledge of the high frequency inductance profile plays an important role in many designs of sensorless controllers for Surface inductance. A special algorithm is used to decouple the cross-coupling effects between the d-axis and the q-axis, which allows Mounted Permanent Magnet (SMPM...... signals to measure the incremental a separate determination of the d, q inductance profiles as functions of the d, q currents. Experimental results on a commercial SMPM motor using the proposed method are presented in this paper....

  11. Fourier method for modeling slanted lamellar gratings of arbitrary end-surface shapes in conical mounting.

    Science.gov (United States)

    Li, Lifeng

    2015-10-01

    An efficient modal method for numerically modeling slanted lamellar gratings of isotropic dielectric or metallic media in conical mounting is presented. No restrictions are imposed on the slant angle and the length of the lamellae. The end surface of the lamellae can be arbitrary, subject to certain restrictions. An oblique coordinate system that is adapted to the slanted lamella sidewalls allows the most efficient way of representing and manipulating the electromagnetic fields. A translational coordinate system that is based on the oblique Cartesian coordinate system adapts to the end-surface profile of the lamellae, so that the latter can be handled simply and easily. Moreover, two matrix eigenvalue problems of size 2N × 2N, one for each fundamental polarization of the electromagnetic fields in the periodic lamellar structure, where N is the matrix truncation number, are derived to replace the 4N × 4N eigenvalue problem that has been used in the literature. The core idea leading to this success is the polarization decomposition of the electromagnetic fields inside the periodic lamellar region when the fields are expressed in the oblique translational coordinate system.

  12. Thermocouple Errors when Mounted on Cylindrical Surfaces in Abnormal Thermal Environments.

    Energy Technology Data Exchange (ETDEWEB)

    Nakos, James T. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Suo-Anttila, Jill M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Zepper, Ethan T. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Koenig, Jerry J [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Valdez, Vincent A. [ECI Inc., Albuquerque, NM (United States)

    2017-05-01

    Mineral-insulated, metal-sheathed, Type-K thermocouples are used to measure the temperature of various items in high-temperature environments, often exceeding 1000degC (1273 K). The thermocouple wires (chromel and alumel) are protected from the harsh environments by an Inconel sheath and magnesium oxide (MgO) insulation. The sheath and insulation are required for reliable measurements. Due to the sheath and MgO insulation, the temperature registered by the thermocouple is not the temperature of the surface of interest. In some cases, the error incurred is large enough to be of concern because these data are used for model validation, and thus the uncertainties of the data need to be well documented. This report documents the error using 0.062" and 0.040" diameter Inconel sheathed, Type-K thermocouples mounted on cylindrical surfaces (inside of a shroud, outside and inside of a mock test unit). After an initial transient, the thermocouple bias errors typically range only about +-1-2% of the reading in K. After all of the uncertainty sources have been included, the total uncertainty to 95% confidence, for shroud or test unit TCs in abnormal thermal environments, is about +-2% of the reading in K, lower than the +-3% typically used for flat shrouds. Recommendations are provided in Section 6 to facilitate interpretation and use of the results. .

  13. MM99.50 - Surface Topography Characterization Using an Atomic Force Microscope Mounted on a Coordinate Measuring Machine

    DEFF Research Database (Denmark)

    Chiffre, Leonardo De; Hansen, Hans Nørgaard; Kofod, Niels

    1999-01-01

    The paper describes the construction, testing and use of an integrated system for topographic characterization of fine surfaces on parts having relatively big dimensions. An atomic force microscope (AFM) was mounted on a manual three-coordinate measuring machine (CMM) achieving free positioning o...

  14. Recent Developments of Reflectarray Antennas for Reconfigurable Beams Using Surface-Mounted RF-MEMS

    Directory of Open Access Journals (Sweden)

    Eduardo Carrasco

    2012-01-01

    Full Text Available Some of the most recent developments in reconfigurable reflectarrays using surface-mounted RF-MEMS, which have been developed at the Universidad Politécnica de Madrid, are summarized in this paper. The results include reconfigurable elements based on patches aperture-coupled to delay lines in two configurations: single elements and gathered elements which form subarrays with common phase control. The former include traditional aperture-coupled elements and a novel wideband reflectarray element which has been designed using two stacked patches. The latter are proposed as a low cost solution for reducing the number of electronic control devices as well as the manufacturing complexity of large reflectarrays. The main advantages and drawbacks of the grouping are evaluated in both pencil and shaped-beam antennas. In all the cases, the effects of the MEMS switches and their assembly circuitry are evaluated when they are used in a 2-bit phase shifter which can be extended to more bits, demonstrating that the proposed elements can be used efficiently in reconfigurable-beam reflectarrays.

  15. Flexural strengthening of reinforced lightweight polystyrene aggregate concrete beams with near-surface mounted GFRP bars

    Energy Technology Data Exchange (ETDEWEB)

    Tang, W.C.; Balendran, R.V.; Nadeem, A.; Leung, H.Y. [City University of Hong Kong (China). Department of Building and Construction

    2006-10-15

    Application of near-surface mounted (NSM) fibre reinforced polymer (FRP) bars is emerging as a promising technology for increasing flexural and shear strength of deficient reinforced concrete (RC) members. In order for this technique to perform effectively, the structural behaviour of RC elements strengthened with NSM FRP bars needs to be fully characterized. This paper focuses on the characterization of flexural behaviour of RC members strengthened with NSM glass-FRP bars. Totally, 10 beams were tested using symmetrical two-point loads test. The parameters examined under the beam tests were type of concretes (lightweight polystyrene aggregate concrete and normal concrete), type of reinforcing bars (GFRP and steel), and type of adhesives. Flexural performance of the tested beams including modes of failure, moment-deflection response and ultimate moment capacity are presented and discussed in this paper. Results of this investigation showed that beams with NSM GFRP bars showed a reduction in ultimate deflection and an improvement in flexural stiffness and bending capacity, depending on the PA content of the beams. In general, beams strengthened with NSM GFRP bars overall showed a significant increase in ultimate moment ranging from 23% to 53% over the corresponding beams without NSM GFRP bars. The influence of epoxy type was found conspicuously dominated the moment-deflection response up to the peak moment. Besides, the ultimate moment of concrete beams reinforced with GFRP bars could be predicted satisfactorily using the equation provided in ACI 318-95 Building Code. (author)

  16. Fatigue damage behavior of a surface-mount electronic package under different cyclic applied loads

    Science.gov (United States)

    Ren, Huai-Hui; Wang, Xi-Shu

    2014-04-01

    This paper studies and compares the effects of pull-pull and 3-point bending cyclic loadings on the mechanical fatigue damage behaviors of a solder joint in a surface-mount electronic package. The comparisons are based on experimental investigations using scanning electron microscopy (SEM) in-situ technology and nonlinear finite element modeling, respectively. The compared results indicate that there are different threshold levels of plastic strain for the initial damage of solder joints under two cyclic applied loads; meanwhile, fatigue crack initiation occurs at different locations, and the accumulation of equivalent plastic strain determines the trend and direction of fatigue crack propagation. In addition, simulation results of the fatigue damage process of solder joints considering a constitutive model of damage initiation criteria for ductile materials and damage evolution based on accumulating inelastic hysteresis energy are identical to the experimental results. The actual fatigue life of the solder joint is almost the same and demonstrates that the FE modeling used in this study can provide an accurate prediction of solder joint fatigue failure.

  17. Milk-run kanban system for raw printed circuit board withdrawal to surface-mounted equipment

    Directory of Open Access Journals (Sweden)

    Swee Li Chee

    2012-12-01

    Full Text Available Purpose:  The paper aims to present a case study and later simulation analysis on a kanban system that incorporating milk-run operation to draw in raw material to the process. Design/methodology/approach:  Data collection at the case study company for ten weeks followed by a process study called value stream mapping. The proposed kanban model is simulated to test its various performances including total output, average flow time, average work-in-process, SME utilization, and average waiting time. Response surface methodology is adopted to generate suitable representative regression models.  Findings: For all performance measures, simulation results showed that the proposed system consistently outperforms the push system currently practiced. Second, the system indicates the advantages of leveling, particularly in the event of machine failure and blockage. Third, operator in the proposed kanban system has a lower utilization, even with the additional material handling task.   Research limitations/implications: This study only begins to reveal the implication of leveling for production control on multi-machine scenario. The simulation of the system is solely based only the case study. The control parameters critical to the case study, were naturally used. The furtherance of the research should include generalizing the system and devising the respective methodology to facilitate wider applications. Practical implications: Originality/value:  The kanban system is proposed in the light of conflicting interests in handling the surface mounting and the related upstream processes. Such aspect is common to electronics assembly industry.

  18. Assessing and Mapping of Road Surface Roughness based on GPS and Accelerometer Sensors on Bicycle-Mounted Smartphones

    Science.gov (United States)

    Shen, Jie; Wan, Mi; Shi, Jiafeng

    2018-01-01

    The surface roughness of roads is an essential road characteristic. Due to the employed carrying platforms (which are often cars), existing measuring methods can only be used for motorable roads. Until now, there has been no effective method for measuring the surface roughness of un-motorable roads, such as pedestrian and bicycle lanes. This hinders many applications related to pedestrians, cyclists and wheelchair users. In recognizing these research gaps, this paper proposes a method for measuring the surface roughness of pedestrian and bicycle lanes based on Global Positioning System (GPS) and accelerometer sensors on bicycle-mounted smartphones. We focus on the International Roughness Index (IRI), as it is the most widely used index for measuring road surface roughness. Specifically, we analyzed a computing model of road surface roughness, derived its parameters with GPS and accelerometers on bicycle-mounted smartphones, and proposed an algorithm to recognize potholes/humps on roads. As a proof of concept, we implemented the proposed method in a mobile application. Three experiments were designed to evaluate the proposed method. The results of the experiments show that the IRI values measured by the proposed method were strongly and positively correlated with those measured by professional instruments. Meanwhile, the proposed algorithm was able to recognize the potholes/humps that the bicycle passed. The proposed method is useful for measuring the surface roughness of roads that are not accessible for professional instruments, such as pedestrian and cycle lanes. This work enables us to further study the feasibility of crowdsourcing road surface roughness with bicycle-mounted smartphones. PMID:29562731

  19. Photovoltaic mounting/demounting unit

    DEFF Research Database (Denmark)

    2014-01-01

    The present invention relates to a photovoltaic arrangement comprising a photovoltaic assembly comprising a support structure defining a mounting surface onto which a photovoltaic module is detachably mounted; and a mounting/demounting unit comprising at least one mounting/demounting apparatus...... which when the mounting/demounting unit is moved along the mounting surface, causes the photovoltaic module to be mounted or demounted to the support structure; wherein the photovoltaic module comprises a carrier foil and wherein a total thickness of the photo voltaic module is below 500 muiotaeta....... The present invention further relates to an associated method for mounting/demounting photovoltaic modules....

  20. Photocatalytic disinfection of surfaces with copper doped Ti02 nanotube coatings illuminated by ceiling mounted fluorescent light

    Science.gov (United States)

    Koklic, Tilen; Pintarič, Štefan; Zdovc, Irena; Golob, Majda; Umek, Polona; Mehle, Alma; Dobeic, Martin; Štrancar, Janez

    2018-01-01

    High economic burden is associated with foodborne illnesses. Different disinfection methods are therefore employed in food processing industry; such as use of ultraviolet light or usage of surfaces with copper-containing alloys. However, all the disinfection methods currently in use have some shortcomings. In this work we show that copper doped TiO2 nanotubes deposited on existing surfaces and illuminated with ceiling mounted fluorescent lights can retard the growth of Listeria Innocua by 80% in seven hours of exposure to the fluorescent lights at different places in a food processing plant or in the laboratory conditions with daily reinocuation and washing. The disinfection properties of the surfaces seem to depend mainly on the temperature difference of the surface and the dew point, where for the maximum effectiveness the difference should be about 3 degrees celsius. The TiO2 nanotubes have a potential to be employed for an economical and continuous disinfection of surfaces. PMID:29768464

  1. Photovoltaic module mounting system

    Science.gov (United States)

    Miros, Robert H. J. [Fairfax, CA; Mittan, Margaret Birmingham [Oakland, CA; Seery, Martin N [San Rafael, CA; Holland, Rodney H [Novato, CA

    2012-04-17

    A solar array mounting system having unique installation, load distribution, and grounding features, and which is adaptable for mounting solar panels having no external frame. The solar array mounting system includes flexible, pedestal-style feet and structural links connected in a grid formation on the mounting surface. The photovoltaic modules are secured in place via the use of attachment clamps that grip the edge of the typically glass substrate. The panel mounting clamps are then held in place by tilt brackets and/or mid-link brackets that provide fixation for the clamps and align the solar panels at a tilt to the horizontal mounting surface. The tilt brackets are held in place atop the flexible feet and connected link members thus creating a complete mounting structure.

  2. Studies on surface-mounted SiPMs in 2015 testbeam of a highly granular hadron calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Krause, Sascha [Institut fuer Physik, Johannes Gutenberg-Universitaet Mainz, Mainz (Germany); Collaboration: CALICE-D-Collaboration

    2016-07-01

    To achieve excellent jet energy resolution, a highly granular hadronic calorimeter is being developed within the CALICE collaboration. Therefore, about 8 million detector units consisting of scintillator tiles and silicon photomultipliers (SiPMs) will be installed in the final HCAL design. The usage of surface-mounted (SMD) SiPMs allows an automated mass assembly. During CERN SPS testbeam 2015, data for a prototype consisting of up to 11 layers of HCAL base units (HBU) was collected using electron, muon and pion beams. One of the layers was equipped with the first SMD HBU. Results and performance, especially of the SMD HBU are presented.

  3. Determination of High-Frequency d- and q-axis Inductances for Surface-Mounted Permanent-Magnet Synchronous Machines

    DEFF Research Database (Denmark)

    Lu, Kaiyuan; Vetuschi, M.; Rasmussen, Peter Omand

    2010-01-01

    This paper presents a reliable method for the experimental determination of high-frequency d- and q -axis inductances for surface-mounted permanent-magnet synchronous machines (SMPMSMs). Knowledge of the high-frequency d- and q-axis inductances plays an important role in the efficient design...... of sensorless controllers using high-frequency signal injection techniques. The proposed method employs a static locked-rotor test using an ac +dc power supply. By injecting a high-frequency rotating voltage vector into the machine, the d- and q-axis inductances may simultaneously be determined with no need...

  4. On the analytical flux distribution modeling of an axial-flux surface-mounted permanent magnet motor for control applications

    International Nuclear Information System (INIS)

    Liu, C.-T.; Lin, S.-C.; Chiang, T.-S.

    2004-01-01

    By combining the recoil line characteristics of permanent magnet and the equivalent operational magnetic circuits at various rotor positions, a systematic procedure for developing the desired analytical model of an axial-flux surface-mounted permanent magnet motor can be devised. Supported by detailed three-dimensional finite element analysis results and statistical evaluations, accuracies of the developed analytical model can be guaranteed. With such well developed system model, the relative high-precision controls and operations of the motor can then be conveniently realized

  5. Two small lymphocyte subpopulations in human peripheral blood. I. Purification and surface marker profiles

    DEFF Research Database (Denmark)

    Hokland, M; Hokland, P; Heron, I

    1978-01-01

    By means of simple rosette sedimentation methods two subsets from human peripheral blood lymphocytes have been isolated: (1) (E, Fc)- and (2) (E, Ig)-. The first subset was obtained by centrifuging suspensions of macrophage-depleted PBL in which E and EA rosettes had been allowed to form simultan......By means of simple rosette sedimentation methods two subsets from human peripheral blood lymphocytes have been isolated: (1) (E, Fc)- and (2) (E, Ig)-. The first subset was obtained by centrifuging suspensions of macrophage-depleted PBL in which E and EA rosettes had been allowed to form...... simultaneously. The dominant marker of these E- Fc- cells was surface Ig, and during 4 days of culture this population did not alter its surface markers. Subset 2 was obtained in two ways following rosette centrifugation with AET-treated SRBC and rabbit anti-human Ig-coated autologous RBC. This 'Null cell...

  6. Landscape Response to the 1980 Eruption of Mount St. Helens: Using Historical Aerial Photography to Measure Surface Change

    Science.gov (United States)

    Sweeney, K.; Major, J. J.

    2016-12-01

    Advances in structure-from-motion (SfM) photogrammetry and point cloud comparison have fueled a proliferation of studies using modern imagery to monitor geomorphic change. These techniques also have obvious applications for reconstructing historical landscapes from vertical aerial imagery, but known challenges include insufficient photo overlap, systematic "doming" induced by photo-spacing regularity, missing metadata, and lack of ground control. Aerial imagery of landscape change in the North Fork Toutle River (NFTR) following the 1980 eruption of Mount St. Helens is a prime dataset to refine methodologies. In particular, (1) 14-μm film scans are available for 1:9600 images at 4-month intervals from 1980 - 1986, (2) the large magnitude of landscape change swamps systematic error and noise, and (3) stable areas (primary deposit features, roads, etc.) provide targets for both ground control and matching to modern lidar. Using AgiSoft PhotoScan, we create digital surface models from the NFTR imagery and examine how common steps in SfM workflows affect results. Tests of scan quality show high-resolution, professional film scans are superior to office scans of paper prints, reducing spurious points related to scan infidelity and image damage. We confirm earlier findings that cropping and rotating images improves point matching and the final surface model produced by the SfM algorithm. We demonstrate how the iterative closest point algorithm, implemented in CloudCompare and using modern lidar as a reference dataset, can serve as an adequate substitute for absolute ground control. Elevation difference maps derived from our surface models of Mount St. Helens show patterns consistent with field observations, including channel avulsion and migration, though systematic errors remain. We suggest that subtracting an empirical function fit to the long-wavelength topographic signal may be one avenue for correcting systematic error in similar datasets.

  7. Relationship between ocular surface temperature and peripheral vasoconstriction in healthy subjects: a thermographic study.

    Science.gov (United States)

    Vannetti, Federica; Matteoli, Sara; Finocchio, Lucia; Lacarbonara, Francesco; Sodi, Andrea; Menchini, Ugo; Corvi, Andrea

    2014-03-01

    An impairment of ocular blood flow regulation is commonly considered one of the main pathogenetic mechanisms involved in the development of several eye diseases, like glaucoma. The aim of this study was to investigate whether an alteration of ocular blood supply induced by peripheral vasoconstriction might be detected by measuring the ocular surface temperature. The ocular surface temperature was evaluated in a group of 38 healthy young subjects (28 males and 10 females; mean age: 25.4 ± 4.1 years) by infrared thermography. For each subject, the experimental procedure consisted of two thermographic acquisitions both lasting 10 s, recorded before and during the immersion of both hands in a mixture of ice and water (1.6 °C ± 0.4 °C). Specifically, the second acquisition began 20 s after the hand immersion. Analysis of variance was used to compare the ocular surface temperature of the two profiles. The analysis of infrared images was carried out every 2 s: at the eye opening (t(0)) until 10 s (t(5)), for both profiles. Data showed that ocular surface temperature increased significantly (p-value temperature at t(0) for P(1) = 0.12 °C ± 0.13 °C). Therefore, these results suggest a response of the ocular hemodynamic to the peripheral vasoconstriction. The ocular surface temperature may represent a cheap, non-invasive and non-time-consuming test to evaluate ocular vaso-regulation.

  8. A Torque Error Compensation Algorithm for Surface Mounted Permanent Magnet Synchronous Machines with Respect to Magnet Temperature Variations

    Directory of Open Access Journals (Sweden)

    Chang-Seok Park

    2017-09-01

    Full Text Available This paper presents a torque error compensation algorithm for a surface mounted permanent magnet synchronous machine (SPMSM through real time permanent magnet (PM flux linkage estimation at various temperature conditions from medium to rated speed. As known, the PM flux linkage in SPMSMs varies with the thermal conditions. Since a maximum torque per ampere look up table, a control method used for copper loss minimization, is developed based on estimated PM flux linkage, variation of PM flux linkage results in undesired torque development of SPMSM drives. In this paper, PM flux linkage is estimated through a stator flux linkage observer and the torque error is compensated in real time using the estimated PM flux linkage. In this paper, the proposed torque error compensation algorithm is verified in simulation and experiment.

  9. Model reference adaptive control (MRAC)-based parameter identification applied to surface-mounted permanent magnet synchronous motor

    Science.gov (United States)

    Zhong, Chongquan; Lin, Yaoyao

    2017-11-01

    In this work, a model reference adaptive control-based estimated algorithm is proposed for online multi-parameter identification of surface-mounted permanent magnet synchronous machines. By taking the dq-axis equations of a practical motor as the reference model and the dq-axis estimation equations as the adjustable model, a standard model-reference-adaptive-system-based estimator was established. Additionally, the Popov hyperstability principle was used in the design of the adaptive law to guarantee accurate convergence. In order to reduce the oscillation of identification result, this work introduces a first-order low-pass digital filter to improve precision regarding the parameter estimation. The proposed scheme was then applied to an SPM synchronous motor control system without any additional circuits and implemented using a DSP TMS320LF2812. For analysis, the experimental results reveal the effectiveness of the proposed method.

  10. Prestressing Effects on the Performance of Concrete Beams with Near-surface-mounted Carbon-fiber-reinforced Polymer Bars

    Science.gov (United States)

    Hong, Sungnam; Park, Sun-Kyu

    2016-07-01

    The effects of various prestressing levels on the flexural behavior of concrete beams strengthened with prestressed near-surface-mounted (NSM) carbon-fiber-reinforced polymer (CFRP) bars were investigated in this study. Four-point flexural tests up to failure were performed using a total of six strengthened prestressed and nonprestressed concrete beams. The nonprestressed strengthened beam failed by premature debonding at the interface of concrete and the epoxy adhesive, but the prestressed one failed owing due to rupture of the CFRP bar. As the prestressing level of the CFRP bar increased, the cracking and yield loads of the prestressed beams increased, but its effect on their deflections was insignificant. The ultimate load was constant regardless of prestressing level, but the ultimate deflection was almost inversely proportional to the level.

  11. Fundamentally excited flow past a surface-mounted rib. Part I ...

    Indian Academy of Sciences (India)

    Springer Verlag Heidelberg #4 2048 1996 Dec 15 10:16:45

    structures contrary to the traditional belief that large eddies break into small scales at the .... The instantaneous streamwise velocity component (u(x,y,t)) can be decomposed into ..... rib surface where the velocity in the shear layer reaches a maximum value. ..... measurements and mode generation in the pairing process.

  12. Sample mounting and transfer for coupling an ultrahigh vacuum variable temperature beetle scanning tunneling microscope with conventional surface probes

    International Nuclear Information System (INIS)

    Nafisi, Kourosh; Ranau, Werner; Hemminger, John C.

    2001-01-01

    We present a new ultrahigh vacuum (UHV) chamber for surface analysis and microscopy at controlled, variable temperatures. The new instrument allows surface analysis with Auger electron spectroscopy, low energy electron diffraction, quadrupole mass spectrometer, argon ion sputtering gun, and a variable temperature scanning tunneling microscope (VT-STM). In this system, we introduce a novel procedure for transferring a sample off a conventional UHV manipulator and onto a scanning tunneling microscope in the conventional ''beetle'' geometry, without disconnecting the heating or thermocouple wires. The microscope, a modified version of the Besocke beetle microscope, is mounted on a 2.75 in. outer diameter UHV flange and is directly attached to the base of the chamber. The sample is attached to a tripod sample holder that is held by the main manipulator. Under UHV conditions the tripod sample holder can be removed from the main manipulator and placed onto the STM. The VT-STM has the capability of acquiring images between the temperature range of 180--500 K. The performance of the chamber is demonstrated here by producing an ordered array of island vacancy defects on a Pt(111) surface and obtaining STM images of these defects

  13. Cogging torque optimization in surface-mounted permanent-magnet motors by using design of experiment

    Energy Technology Data Exchange (ETDEWEB)

    Abbaszadeh, K., E-mail: Abbaszadeh@kntu.ac.ir [Department of Electrical Engineering, K.N. Toosi University of Technology, Tehran (Iran, Islamic Republic of); Rezaee Alam, F.; Saied, S.A. [Department of Electrical Engineering, K.N. Toosi University of Technology, Tehran (Iran, Islamic Republic of)

    2011-09-15

    Graphical abstract: Magnet segment arrangement in cross section view of one pole for PM machine. Display Omitted Highlights: {yields} Magnet segmentation is an effective method for the cogging torque reduction. {yields} We have used the magnet segmentation method based on the design of experiment. {yields} We have used the RSM design of the design of experiment method. {yields} We have solved optimization via surrogate models like the polynomial regression. {yields} A significant reduction of the cogging torque is obtained by using RSM. - Abstract: One of the important challenges in design of the PM electrical machines is to reduce the cogging torque. In this paper, in order to reduce the cogging torque, a new method for designing of the motor magnets is introduced to optimize of a six pole BLDC motor by using design of experiment (DOE) method. In this method the machine magnets consist of several identical segments which are shifted to a definite angle from each other. Design of experiment (DOE) methodology is used for a screening of the design space and for the generation of approximation models using response surface techniques. In this paper, optimization is often solved via surrogate models, that is, through the construction of response surface models (RSM) like polynomial regression. The experiments were performed based on the response surface methodology (RSM), as a statistical design of experiment approach, in order to investigate the effect of parameters on the response variations. In this investigation, the optimal shifting angles (factors) were identified to minimize the cogging torque. A significant reduction of cogging torque can be achieved with this approach after only a few evaluations of the coupled FE model.

  14. Cogging torque optimization in surface-mounted permanent-magnet motors by using design of experiment

    International Nuclear Information System (INIS)

    Abbaszadeh, K.; Rezaee Alam, F.; Saied, S.A.

    2011-01-01

    Graphical abstract: Magnet segment arrangement in cross section view of one pole for PM machine. Display Omitted Highlights: → Magnet segmentation is an effective method for the cogging torque reduction. → We have used the magnet segmentation method based on the design of experiment. → We have used the RSM design of the design of experiment method. → We have solved optimization via surrogate models like the polynomial regression. → A significant reduction of the cogging torque is obtained by using RSM. - Abstract: One of the important challenges in design of the PM electrical machines is to reduce the cogging torque. In this paper, in order to reduce the cogging torque, a new method for designing of the motor magnets is introduced to optimize of a six pole BLDC motor by using design of experiment (DOE) method. In this method the machine magnets consist of several identical segments which are shifted to a definite angle from each other. Design of experiment (DOE) methodology is used for a screening of the design space and for the generation of approximation models using response surface techniques. In this paper, optimization is often solved via surrogate models, that is, through the construction of response surface models (RSM) like polynomial regression. The experiments were performed based on the response surface methodology (RSM), as a statistical design of experiment approach, in order to investigate the effect of parameters on the response variations. In this investigation, the optimal shifting angles (factors) were identified to minimize the cogging torque. A significant reduction of cogging torque can be achieved with this approach after only a few evaluations of the coupled FE model.

  15. Effect of Surface Pore Structure of Nerve Guide Conduit on Peripheral Nerve Regeneration

    Science.gov (United States)

    Oh, Se Heang; Kim, Jin Rae; Kwon, Gu Birm; Namgung, Uk; Song, Kyu Sang

    2013-01-01

    Polycaprolactone (PCL)/Pluronic F127 nerve guide conduits (NGCs) with different surface pore structures (nano-porous inner surface vs. micro-porous inner surface) but similar physical and chemical properties were fabricated by rolling the opposite side of asymmetrically porous PCL/F127 membranes. The effect of the pore structure on peripheral nerve regeneration through the NGCs was investigated using a sciatic nerve defect model of rats. The nerve fibers and tissues were shown to have regenerated along the longitudinal direction through the NGC with a nano-porous inner surface (Nanopore NGC), while they grew toward the porous wall of the NGC with a micro-porous inner surface (Micropore NGC) and, thus, their growth was restricted when compared with the Nanopore NGC, as investigated by immunohistochemical evaluations (by fluorescence microscopy with anti-neurofilament staining and Hoechst staining for growth pattern of nerve fibers), histological evaluations (by light microscopy with Meyer's modified trichrome staining and Toluidine blue staining and transmission electron microscopy for the regeneration of axon and myelin sheath), and FluoroGold retrograde tracing (for reconnection between proximal and distal stumps). The effect of nerve growth factor (NGF) immobilized on the pore surfaces of the NGCs on nerve regeneration was not so significant when compared with NGCs not containing immobilized NGF. The NGC system with different surface pore structures but the same chemical/physical properties seems to be a good tool that is used for elucidating the surface pore effect of NGCs on nerve regeneration. PMID:22871377

  16. Micro-structured rough surfaces by laser etching for heat transfer enhancement on flush mounted heat sinks

    International Nuclear Information System (INIS)

    Ventola, L; Scaltrito, L; Ferrero, S; Chiavazzo, E; Asinari, P; Maccioni, G

    2014-01-01

    The aim of this work is to improve heat transfer performances of flush mounted heat sinks used in electronic cooling. To do this we patterned 1.23 cm 2 heat sinks surfaces by microstructured roughnesses built by laser etching manufacturing technique, and experimentally measured the convective heat transfer enhancements due to different patterns. Each roughness differs from the others with regards to the number and the size of the micro-fins (e.g. the micro- fin length ranges from 200 to 1100 μm). Experimental tests were carried out in forced air cooling regime. In particular fully turbulent flows (heating edge based Reynolds number ranging from 3000 to 17000) were explored. Convective heat transfer coefficient of the best micro-structured heat sink is found to be roughly two times compared to the smooth heat sinks one. In addition, surface area roughly doubles with regard to smooth heat sinks, due to the presence of micro-fins. Consequently, patterned heat sinks thermal transmittance [W/K] is found to be roughly four times the smooth heat sinks one. We hope this work may open the way for huge boost in the technology of electronic cooling by innovative manufacturing techniques.

  17. A design of scintillator tiles read out by surface-mounted SiPMs for a future hadron calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yong; Bauss, Bruno; Buescher, Volker; Caudron, Julien; Chau, Phi; Degele, Reinhold; Geib, Karl-Heinrich; Masetti, Lucia; Schaefer, Ulrich; Tapprogge, Stefan; Wanke, Rainer [Institut fuer Physik and PRISMA Detector Lab, Johannes Gutenberg-Universitaet Mainz (Germany)

    2015-07-01

    Precision calorimetry using highly granular sampling calorimeters is being developed based on the particle flow concept within the CALICE collaboration. One design option of a hadron calorimeter is based on silicon photomultipliers (SiPMs) to detect photons generated in plastic scintillator tiles. Driven by the need of automated mass assembly of around ten millions of channels stringently required by the high granularity, we developed a design of scintillator tiles directly coupled with surface-mounted SiPMs. A cavity is created in the center of the bottom surface of each tile to provide enough room for the whole SiPM package and to improve collection of the light produced by incident particles penetrating the tile at different positions. The cavity design has been optimized using a GEANT4-based full simulation model to achieve high response to Minimum Ionizing Particles (MIPs) and also good areal uniformity. Cosmic-ray measurements confirms high 1-MIP response for scintillator tiles with an optimized cavity design. Uniformity measurements by scanning the tile area using focused electrons from a beta source show excellent response uniformity. This optimized design is well beyond the requirements for a precision hadron calorimeter.

  18. Peri-Elastodynamic Simulations of Guided Ultrasonic Waves in Plate-Like Structure with Surface Mounted PZT

    Directory of Open Access Journals (Sweden)

    Subir Patra

    2018-01-01

    Full Text Available Peridynamic based elastodynamic computation tool named Peri-elastodynamics is proposed herein to simulate the three-dimensional (3D Lamb wave modes in materials for the first time. Peri-elastodynamics is a nonlocal meshless approach which is a scale-independent generalized technique to visualize the acoustic and ultrasonic waves in plate-like structure, micro-electro-mechanical systems (MEMS and nanodevices for their respective characterization. In this article, the characteristics of the fundamental Lamb wave modes are simulated in a sample plate-like structure. Lamb wave modes are generated using a surface mounted piezoelectric (PZT transducer which is actuated from the top surface. The proposed generalized Peri-elastodynamics method is not only capable of simulating two dimensional (2D in plane wave under plane strain condition formulated previously but also capable of accurately simulating the out of plane Symmetric and Antisymmetric Lamb wave modes in plate like structures in 3D. For structural health monitoring (SHM of plate-like structures and nondestructive evaluation (NDE of MEMS devices, it is necessary to simulate the 3D wave-damage interaction scenarios and visualize the different wave features due to damages. Hence, in addition, to simulating the guided ultrasonic wave modes in pristine material, Lamb waves were also simulated in a damaged plate. The accuracy of the proposed technique is verified by comparing the modes generated in the plate and the mode shapes across the thickness of the plate with theoretical wave analysis.

  19. Peri-Elastodynamic Simulations of Guided Ultrasonic Waves in Plate-Like Structure with Surface Mounted PZT.

    Science.gov (United States)

    Patra, Subir; Ahmed, Hossain; Banerjee, Sourav

    2018-01-18

    Peridynamic based elastodynamic computation tool named Peri-elastodynamics is proposed herein to simulate the three-dimensional (3D) Lamb wave modes in materials for the first time. Peri-elastodynamics is a nonlocal meshless approach which is a scale-independent generalized technique to visualize the acoustic and ultrasonic waves in plate-like structure, micro-electro-mechanical systems (MEMS) and nanodevices for their respective characterization. In this article, the characteristics of the fundamental Lamb wave modes are simulated in a sample plate-like structure. Lamb wave modes are generated using a surface mounted piezoelectric (PZT) transducer which is actuated from the top surface. The proposed generalized Peri-elastodynamics method is not only capable of simulating two dimensional (2D) in plane wave under plane strain condition formulated previously but also capable of accurately simulating the out of plane Symmetric and Antisymmetric Lamb wave modes in plate like structures in 3D. For structural health monitoring (SHM) of plate-like structures and nondestructive evaluation (NDE) of MEMS devices, it is necessary to simulate the 3D wave-damage interaction scenarios and visualize the different wave features due to damages. Hence, in addition, to simulating the guided ultrasonic wave modes in pristine material, Lamb waves were also simulated in a damaged plate. The accuracy of the proposed technique is verified by comparing the modes generated in the plate and the mode shapes across the thickness of the plate with theoretical wave analysis.

  20. Slot opening optimization of surface mounted permanent magnet motor for cogging torque reduction

    International Nuclear Information System (INIS)

    Abbaszadeh, K.; Rezaee Alam, F.; Teshnehlab, M.

    2012-01-01

    Highlights: ► The slot opening shift method is an efficient method for cogging torque reduction. ► Using slot opening skew method, the trapezoidal waveform of back-emf is maintained. ► Using the conventional slot skewing, the wave shape of back-emf is sinusoidal. ► The novelty of paper is using of air–gap permeance harmonics as objective function. ► Other novelty of this paper is using the different optimization algorithms. - Abstract: In this paper, slot opening skew method is used for cogging torque reduction. A three layer stator model is considered for a six-pole PM-BLDC motor (a PM-BLDC motor with 18-slots, six-poles and length of 5 cm) and then a 2D dual model is extracted for this 3D slot opening skew model. The angular shifts of slot opening position in the first and third layers than middle layer are considered as optimization parameters. Slot opening shape is optimized by using different optimization algorithms, such as, the response surface methodology (RSM), the genetic algorithm (GA) and the particle swarm optimization (PSO). In order to using of GA and PSO, the analytical relationship is derived for the air–gap permeance function. The optimization results of these algorithms are being consistent with each other and are verified with FEA results. The results show the significant reduction of cogging torque about 77%.

  1. Optoelectronic Mounting Structure

    Science.gov (United States)

    Anderson, Gene R.; Armendariz, Marcelino G.; Baca, Johnny R. F.; Bryan, Robert P.; Carson, Richard F.; Chu, Dahwey; Duckett, III, Edwin B.; McCormick, Frederick B.; Peterson, David W.; Peterson, Gary D.; Reber, Cathleen A.; Reysen, Bill H.

    2004-10-05

    An optoelectronic mounting structure is provided that may be used in conjunction with an optical transmitter, receiver or transceiver module. The mounting structure may be a flexible printed circuit board. Thermal vias or heat pipes in the head region may transmit heat from the mounting structure to the heat spreader. The heat spreader may provide mechanical rigidity or stiffness to the heat region. In another embodiment, an electrical contact and ground plane may pass along a surface of the head region so as to provide an electrical contact path to the optoelectronic devices and limit electromagnetic interference. In yet another embodiment, a window may be formed in the head region of the mounting structure so as to provide access to the heat spreader. Optoelectronic devices may be adapted to the heat spreader in such a manner that the devices are accessible through the window in the mounting structure.

  2. Modeling guided wave excitation in plates with surface mounted piezoelectric elements: coupled physics and normal mode expansion

    Science.gov (United States)

    Ren, Baiyang; Lissenden, Cliff J.

    2018-04-01

    Guided waves have been extensively studied and widely used for structural health monitoring because of their large volumetric coverage and good sensitivity to defects. Effectively and preferentially exciting a desired wave mode having good sensitivity to a certain defect is of great practical importance. Piezoelectric discs and plates are the most common types of surface-mounted transducers for guided wave excitation and reception. Their geometry strongly influences the proportioning between excited modes as well as the total power of the excited modes. It is highly desirable to predominantly excite the selected mode while the total transduction power is maximized. In this work, a fully coupled multi-physics finite element analysis, which incorporates the driving circuit, the piezoelectric element and the wave guide, is combined with the normal mode expansion method to study both the mode tuning and total wave power. The excitation of circular crested waves in an aluminum plate with circular piezoelectric discs is numerically studied for different disc and adhesive thicknesses. Additionally, the excitation of plane waves in an aluminum plate, using a stripe piezoelectric element is studied both numerically and experimentally. It is difficult to achieve predominant single mode excitation as well as maximum power transmission simultaneously, especially for higher order modes. However, guidelines for designing the geometry of piezoelectric elements for optimal mode excitation are recommended.

  3. Reliability Study of Solder Paste Alloy for the Improvement of Solder Joint at Surface Mount Fine-Pitch Components

    Directory of Open Access Journals (Sweden)

    Mohd Nizam Ab. Rahman

    2014-12-01

    Full Text Available The significant increase in metal costs has forced the electronics industry to provide new materials and methods to reduce costs, while maintaining customers’ high-quality expectations. This paper considers the problem of most electronic industries in reducing costly materials, by introducing a solder paste with alloy composition tin 98.3%, silver 0.3%, and copper 0.7%, used for the construction of the surface mount fine-pitch component on a Printing Wiring Board (PWB. The reliability of the solder joint between electronic components and PWB is evaluated through the dynamic characteristic test, thermal shock test, and Taguchi method after the printing process. After experimenting with the dynamic characteristic test and thermal shock test with 20 boards, the solder paste was still able to provide a high-quality solder joint. In particular, the Taguchi method is used to determine the optimal control parameters and noise factors of the Solder Printer (SP machine, that affects solder volume and solder height. The control parameters include table separation distance, squeegee speed, squeegee pressure, and table speed of the SP machine. The result shows that the most significant parameter for the solder volume is squeegee pressure (2.0 mm, and the solder height is the table speed of the SP machine (2.5 mm/s.

  4. Finite element modelling to assess the effect of surface mounted piezoelectric patch size on vibration response of a hybrid beam

    Science.gov (United States)

    Rahman, N.; Alam, M. N.

    2018-02-01

    Vibration response analysis of a hybrid beam with surface mounted patch piezoelectric layer is presented in this work. A one dimensional finite element (1D-FE) model based on efficient layerwise (zigzag) theory is used for the analysis. The beam element has eight mechanical and a variable number of electrical degrees of freedom. The beams are also modelled in 2D-FE (ABAQUS) using a plane stress piezoelectric quadrilateral element for piezo layers and a plane stress quadrilateral element for the elastic layers of hybrid beams. Results are presented to assess the effect of size of piezoelectric patch layer on the free and forced vibration responses of thin and moderately thick beams under clamped-free and clamped-clamped configurations. The beams are subjected to unit step loading and harmonic loading to obtain the forced vibration responses. The vibration control using in phase actuation potential on piezoelectric patches is also studied. The 1D-FE results are compared with the 2D-FE results.

  5. Flexural Behavior of Concrete Beam Strengthened by Near-Surface Mounted CFRP Reinforcement Using Equivalent Section Model

    Directory of Open Access Journals (Sweden)

    Woo-tai Jung

    2017-01-01

    Full Text Available FRP (fiber reinforced polymer has found wide applications as an alternative to steel rebar not only for the repair and strengthening of existing structures but also for the erection of new structures. Near-surface mounted (NSM strengthening was introduced as an alternative of externally bonded reinforcement (EBR but this method also experiences early bond failure, which stresses the importance of predicting accurately the bond failure behavior in order to evaluate precisely the performance of NSM reinforcement. This study proposes the equivalent section model assuming monolithic behavior of the filler and CFRP reinforcement. This equivalent section model enables establishing a bond failure model applicable independently of the sectional shape of the CFRP reinforcement. This so-derived bond failure model is then validated experimentally by means of beams flexure-strengthened by NSM CFRP reinforcements with various cross-sections. Finally, analytical analysis applying the bond failure model considering the equivalent section and defined failure criteria is performed. The results show the accuracy of the prediction of the failure mode as well as the accurate prediction of the experimental results regardless of the sectional shape of the CFRP reinforcement.

  6. Structure Crack Identification Based on Surface-mounted Active Sensor Network with Time-Domain Feature Extraction and Neural Network

    Directory of Open Access Journals (Sweden)

    Chunling DU

    2012-03-01

    Full Text Available In this work the condition of metallic structures are classified based on the acquired sensor data from a surface-mounted piezoelectric sensor/actuator network. The structures are aluminum plates with riveted holes and possible crack damage at these holes. A 400 kHz sine wave burst is used as diagnostic signals. The combination of time-domain S0 waves from received sensor signals is directly used as features and preprocessing is not needed for the dam age detection. Since the time sequence of the extracted S0 has a high dimension, principal component estimation is applied to reduce its dimension before entering NN (neural network training for classification. An LVQ (learning vector quantization NN is used to classify the conditions as healthy or damaged. A number of FEM (finite element modeling results are taken as inputs to the NN for training, since the simulated S0 waves agree well with the experimental results on real plates. The performance of the classification is then validated by using these testing results.

  7. Human peripheral blood monocytes display surface antigens recognized by monoclonal antinuclear antibodies

    International Nuclear Information System (INIS)

    Holers, V.M.; Kotzin, B.L.

    1985-01-01

    The authors used monoclonal anti-nuclear autoantibodies and indirect immunofluorescence to examine normal human peripheral blood mononuclear leukocytes for the presence of cell surface nuclear antigens. Only one monoclonal anti-histone antibody (MH-2) was found to bind to freshly isolated PBL, staining approximately 10% of large cells. However, after cells were placed into culture for 16-24 h, a high percentage (up to 60%) of large-sized cells were recognized by an anti-DNA (BWD-1) and several different antihistone monoclonal antibodies (BWH-1, MH-1, and MH-2). These antibodies recognize separate antigenic determinants on chromatin and histones extracted from chromatin. The histone antigen-positive cells were viable, and the monoclonal antibodies could be shown to be binding to the cell surface and not to the nucleus. Using monoclonal antibodies specific for monocytes and T cells, and complement-mediated cytotoxicity, the cells bearing histone antigens were shown to be primarily monocytes. The appearance of histone and DNA antigen-positive cells was nearly completely inhibited by the addition of low concentrations of cycloheximide at initiation of the cultures. In contrast, little effect on the percentage of positive cells was detected if cells were exposed to high doses of gamma irradiation before culture. These data further support the existence of cell surface nuclear antigens on selected cell subsets, which may provide insight into the immunopathogenesis of systemic lupus erythematosus and related autoimmune diseases

  8. Thin concentrator photovoltaic module with micro-solar cells which are mounted by self-align method using surface tension of melted solder

    Science.gov (United States)

    Hayashi, Nobuhiko; Terauchi, Masaharu; Aya, Youichirou; Kanayama, Shutetsu; Nishitani, Hikaru; Nakagawa, Tohru; Takase, Michihiko

    2017-09-01

    We are developing a thin and lightweight CPV module using small size lens system made from poly methyl methacrylate (PMMA) with a short focal length and micro-solar cells to decrease the transporting and the installing costs of CPV systems. In order to achieve high conversion efficiency in CPV modules using micro-solar cells, the micro-solar cells need to be mounted accurately to the irradiated region of the concentrated sunlight. In this study, we have successfully developed self-align method thanks to the surface tension of the melted solder even utilizing commercially available surface-mounting technology (SMT). Solar cells were self-aligned to the specified positions of the circuit board by this self-align method with accuracy within ±10 µm. We actually fabricated CPV modules using this self-align method and demonstrated high conversion efficiency of our CPV module.

  9. Titanium biomaterials with complex surfaces induced aberrant peripheral circadian rhythms in bone marrow mesenchymal stromal cells.

    Science.gov (United States)

    Hassan, Nathaniel; McCarville, Kirstin; Morinaga, Kenzo; Mengatto, Cristiane M; Langfelder, Peter; Hokugo, Akishige; Tahara, Yu; Colwell, Christopher S; Nishimura, Ichiro

    2017-01-01

    Circadian rhythms maintain a high level of homeostasis through internal feed-forward and -backward regulation by core molecules. In this study, we report the highly unusual peripheral circadian rhythm of bone marrow mesenchymal stromal cells (BMSCs) induced by titanium-based biomaterials with complex surface modifications (Ti biomaterial) commonly used for dental and orthopedic implants. When cultured on Ti biomaterials, human BMSCs suppressed circadian PER1 expression patterns, while NPAS2 was uniquely upregulated. The Ti biomaterials, which reduced Per1 expression and upregulated Npas2, were further examined with BMSCs harvested from Per1::luc transgenic rats. Next, we addressed the regulatory relationship between Per1 and Npas2 using BMSCs from Npas2 knockout mice. The Npas2 knockout mutation did not rescue the Ti biomaterial-induced Per1 suppression and did not affect Per2, Per3, Bmal1 and Clock expression, suggesting that the Ti biomaterial-induced Npas2 overexpression was likely an independent phenomenon. Previously, vitamin D deficiency was reported to interfere with Ti biomaterial osseointegration. The present study demonstrated that vitamin D supplementation significantly increased Per1::luc expression in BMSCs, though the presence of Ti biomaterials only moderately affected the suppressed Per1::luc expression. Available in vivo microarray data from femurs exposed to Ti biomaterials in vitamin D-deficient rats were evaluated by weighted gene co-expression network analysis. A large co-expression network containing Npas2, Bmal1, and Vdr was observed to form with the Ti biomaterials, which was disintegrated by vitamin D deficiency. Thus, the aberrant BMSC peripheral circadian rhythm may be essential for the integration of Ti biomaterials into bone.

  10. Genetic Diversity of Plasmodium falciparum Merozoite Surface Protein-1 Block 2 in Sites of Contrasting Altitudes and Malaria Endemicities in the Mount Cameroon Region

    OpenAIRE

    Wanji, Samuel; Kengne-Ouafo, Arnaud J.; Joan Eyong, Ebanga E.; Kimbi, Helen K.; Tendongfor, Nicholas; Ndamukong-Nyanga, Judith L.; Nana-Djeunga, Hugues C.; Bourguinat, Catherine; Sofeu-Feugaing, David D.; Charvet, Claude L.

    2012-01-01

    The present study analyzed the relationship between the genetic diversity of Plasmodium falciparum and parasitologic/entomologic indices in the Mount Cameroon region by using merozoite surface protein 1 as a genetic marker. Blood samples were collected from asymptomatic children from three altitude zones (high, intermediate, and low). Parasitologic and entomologic indices were determined by microscopy and landing catch mosquito collection/circumsporozoite protein–enzyme-linked immunosorbent a...

  11. Housing And Mounting Structure

    Science.gov (United States)

    Anderson, Gene R.; Armendariz, Marcelino G.; Baca, Johnny R.F.; Bryan, Robert P.; Carson, Richard F.; Duckett, III, Edwin B.; McCormick, Frederick B.; Miller, Gregory V.; Peterson, David W.; Smith, Terrance T.

    2005-03-08

    This invention relates to an optical transmitter, receiver or transceiver module, and more particularly, to an apparatus for connecting a first optical connector to a second optical connector. The apparatus comprises: (1) a housing having at least a first end and at least a second end, the first end of the housing capable of receiving the first optical connector, and the second end of the housing capable of receiving the second optical connector; (2) a longitudinal cavity extending from the first end of the housing to the second end of the housing; and (3) an electromagnetic shield comprising at least a portion of the housing. This invention also relates to an apparatus for housing a flexible printed circuit board, and this apparatus comprises: (1) a mounting structure having at least a first surface and a second surface; (2) alignment ridges along the first and second surfaces of the mounting structure, the alignment ridges functioning to align and secure a flexible printed circuit board that is wrapped around and attached to the first and second surfaces of the mounting structure; and (3) a series of heat sink ridges adapted to the mounting structure, the heat sink ridges functioning to dissipate heat that is generated from the flexible printed circuit board.

  12. Flush Mounting Of Thin-Film Sensors

    Science.gov (United States)

    Moore, Thomas C., Sr.

    1992-01-01

    Technique developed for mounting thin-film sensors flush with surfaces like aerodynamic surfaces of aircraft, which often have compound curvatures. Sensor mounted in recess by use of vacuum pad and materials selected for specific application. Technique involves use of materials tailored to thermal properties of substrate in which sensor mounted. Together with customized materials, enables flush mounting of thin-film sensors in most situations in which recesses for sensors provided. Useful in both aircraft and automotive industries.

  13. Peripheral neuropathy

    Science.gov (United States)

    ... peripheral; Neuritis - peripheral; Nerve disease; Polyneuropathy; Chronic pain - peripheral neuropathy ... Philadelphia, PA: Elsevier; 2016:chap 107. Shy ME. Peripheral neuropathies. In: Goldman L, Schafer AI, eds. Goldman's Cecil ...

  14. Relationship between ocular surface temperature and peripheral vasoconstriction in healthy subjects: A thermographic study

    DEFF Research Database (Denmark)

    Matteoli, Sara; Vannetti, Federica; Finocchio, Lucia

    2014-01-01

    An impairment of ocular blood flow regulation is commonly considered one of the main pathogenetic mechanisms involved in the development of several eye diseases, like glaucoma. The aim of this study was to investigate whether an alteration of ocular blood supply induced by peripheral vasoconstric......An impairment of ocular blood flow regulation is commonly considered one of the main pathogenetic mechanisms involved in the development of several eye diseases, like glaucoma. The aim of this study was to investigate whether an alteration of ocular blood supply induced by peripheral...

  15. Quasi-plane-hypothesis of strain coordination for RC beams seismically strengthened with externally-bonded or near-surface mounted fiber reinforced plastic

    Science.gov (United States)

    Ren, Zhenhua; Zeng, Xiantao; Liu, Hanlong; Zhou, Fengjun

    2013-03-01

    The application of fiber reinforced plastic (FRP), including carbon FRP and glass FRP, for structural repair and strengthening has grown due to their numerous advantages over conventional materials such as externally bonded reinforcement (EBR) and near-surface mounted (NSM) strengthening techniques. This paper summarizes the results from 21 reinforced concrete beams strengthened with different methods, including externally-bonded and near-surface mounted FRP, to study the strain coordination of the FRP and steel rebar of the RC beam. Since there is relative slipping between the RC beam and the FRP, the strain of the FRP and steel rebar of the RC beam satisfy the quasi-plane-hypothesis; that is, the strain of the longitudinal fiber that parallels the neutral axis of the plated beam within the scope of the effective height ( h 0) of the cross section is in direct proportion to the distance from the fiber to the neutral axis. The strain of the FRP and steel rebar satisfies the equation: ɛ FRP= βɛ steel, and the value of β is equal to 1.1-1.3 according to the test results.

  16. Layer-by-Layer Method for the Synthesis and Growth of Surface Mounted Metal-Organic Frameworks (SURMOFs

    Directory of Open Access Journals (Sweden)

    Osama Shekhah

    2010-02-01

    Full Text Available A layer-by-layer method has been developed for the synthesis of metal-organic frameworks (MOFs and their deposition on functionalized organic surfaces. The approach is based on the sequential immersion of functionalized organic surfaces into solutions of the building blocks of the MOF, i.e., the organic ligand and the inorganic unit. The synthesis and growth of different types of MOFs on substrates with different functionalization, like COOH, OH and pyridine terminated surfaces, were studied and characterized with different surface characterization techniques. A controlled and highly oriented growth of very homogenous films was obtained using this method. The layer-by-layer method offered also the possibility to study the kinetics of film formation in more detail using surface plasmon resonance and quartz crystal microbalance. In addition, this method demonstrates the potential to synthesize new classes of MOFs not accessible by conventional methods. Finally, the controlled growth of MOF thin films is important for many applications like chemical sensors, membranes and related electrodes.

  17. Detector Mount Design for IGRINS

    Directory of Open Access Journals (Sweden)

    Jae Sok Oh

    2014-06-01

    Full Text Available The Immersion Grating Infrared Spectrometer (IGRINS is a near-infrared wide-band high-resolution spectrograph jointly developed by the Korea Astronomy and Space Science Institute and the University of Texas at Austin. IGRINS employs three HAWAII-2RG Focal Plane Array (H2RG FPA detectors. We present the design and fabrication of the detector mount for the H2RG detector. The detector mount consists of a detector housing, an ASIC housing, a Field Flattener Lens (FFL mount, and a support base frame. The detector and the ASIC housing should be kept at 65 K and the support base frame at 130 K. Therefore they are thermally isolated by the support made of GFRP material. The detector mount is designed so that it has features of fine adjusting the position of the detector surface in the optical axis and of fine adjusting yaw and pitch angles in order to utilize as an optical system alignment compensator. We optimized the structural stability and thermal characteristics of the mount design using computer-aided 3D modeling and finite element analysis. Based on the structural and thermal analysis, the designed detector mount meets an optical stability tolerance and system thermal requirements. Actual detector mount fabricated based on the design has been installed into the IGRINS cryostat and successfully passed a vacuum test and a cold test.

  18. Genetic diversity of Plasmodium falciparum merozoite surface protein-1 block 2 in sites of contrasting altitudes and malaria endemicities in the Mount Cameroon region.

    Science.gov (United States)

    Wanji, Samuel; Kengne-Ouafo, Arnaud J; Eyong, Ebanga E Joan; Kimbi, Helen K; Tendongfor, Nicholas; Ndamukong-Nyanga, Judith L; Nana-Djeunga, Hugues C; Bourguinat, Catherine; Sofeu-Feugaing, David D; Charvet, Claude L

    2012-05-01

    The present study analyzed the relationship between the genetic diversity of Plasmodium falciparum and parasitologic/entomologic indices in the Mount Cameroon region by using merozoite surface protein 1 as a genetic marker. Blood samples were collected from asymptomatic children from three altitude zones (high, intermediate, and low). Parasitologic and entomologic indices were determined by microscopy and landing catch mosquito collection/circumsporozoite protein-enzyme-linked immunosorbent assay, respectively. A total of 142 randomly selected P. falciparum-positive blood samples were genotyped by using a nested polymerase chain reaction-based technique. K-1 polymerase chain reaction products were also sequenced. As opposed to high altitude, the highest malaria prevalence (70.65%) and entomologic inoculation rate (2.43 infective/bites/night) were recorded at a low altitude site. Seven (18.91%), 22 (36.66%), and 19 (42.22%) samples from high, intermediate, and low altitudes, respectively, contained multiclonal infections. A new K-1 polymorphism was identified. This study shows a positive non-linear association between low/intermediate altitude (high malaria transmission) and an increase in P. falciparum merozoite surface protein 1 block 2 polymorphisms.

  19. Effect of surface modification of silica nanoparticles on toxicity and cellular uptake by human peripheral blood lymphocytes in vitro.

    Science.gov (United States)

    Lankoff, Anna; Arabski, Michal; Wegierek-Ciuk, Aneta; Kruszewski, Marcin; Lisowska, Halina; Banasik-Nowak, Anna; Rozga-Wijas, Krystyna; Wojewodzka, Maria; Slomkowski, Stanislaw

    2013-05-01

    Silica nanoparticles have an interesting potential in drug delivery, gene therapy and molecular imaging due to the possibility of tailoring their surface reactivity that can be obtained by surface modification. Despite these potential benefits, there is concern that exposure of humans to certain types of silica nanomaterials may lead to significant adverse health effects. The motivation of this study was to determine the kinetics of cellular binding/uptake of the vinyl- and the aminopropyl/vinyl-modified silica nanoparticles into peripheral blood lymphocytes in vitro, to explore their genotoxic and cytotoxic properties and to compare the biological properties of modified silica nanoparticles with those of the unmodified ones. Size of nanoparticles determined by SEM varied from 10 to 50 nm. The average hydrodynamic diameter and zeta potential also varied from 176.7 nm (+18.16 mV) [aminopropyl/vinyl-modified] and 235.4 nm (-9.49 mV) [vinyl-modified] to 266.3 (-13.32 mV) [unmodified]. Surface-modified silica particles were internalized by lymphocytes with varying efficiency and expressed no cytotoxic nor genotoxic effects, as determined by various methods (cell viability, apoptosis/necrosis, oxidative DNA damage, chromosome aberrations). However, they affected the proliferation of the lymphocytes as indicated by a decrease in mitotic index value and cell cycle progression. In contrast, unmodified silica nanoparticles exhibited cytotoxic and genotoxic properties at high doses as well as interfered with cell cycle.

  20. A Novel Method to Magnetic Flux Linkage Optimization of Direct-Driven Surface-Mounted Permanent Magnet Synchronous Generator Based on Nonlinear Dynamic Analysis

    Directory of Open Access Journals (Sweden)

    Qian Xie

    2016-07-01

    Full Text Available This paper pays attention to magnetic flux linkage optimization of a direct-driven surface-mounted permanent magnet synchronous generator (D-SPMSG. A new compact representation of the D-SPMSG nonlinear dynamic differential equations to reduce system parameters is established. Furthermore, the nonlinear dynamic characteristics of new D-SPMSG equations in the process of varying magnetic flux linkage are considered, which are illustrated by Lyapunov exponent spectrums, phase orbits, Poincaré maps, time waveforms and bifurcation diagrams, and the magnetic flux linkage stable region of D-SPMSG is acquired concurrently. Based on the above modeling and analyses, a novel method of magnetic flux linkage optimization is presented. In addition, a 2 MW D-SPMSG 2D/3D model is designed by ANSYS software according to the practical design requirements. Finally, five cases of D-SPMSG models with different magnetic flux linkages are simulated by using the finite element analysis (FEA method. The nephograms of magnetic flux density are agreement with theoretical analysis, which both confirm the correctness and effectiveness of the proposed approach.

  1. Magnetic core mounting system

    Science.gov (United States)

    Ronning, Jeffrey J.

    2002-01-01

    A mounting apparatus for an electromagnetic device such as a transformer of inductor includes a generally planar metallic plate as a first heat sink, and a metallic mounting cup as a second heat sink. The mounting cup includes a cavity configured to receive the electromagnetic device, the cavity being defined by a base, and an axially-extending annular sidewall extending from the base to a flange portion of the mounting cup. The mounting cup includes first and second passages for allowing the leads of first and second windings of the electromagnetic device to be routed out of the cavity. The cavity is filled with a polyurethane potting resin, and the mounting cup, including the potted electromagnetic device, is mounted to the plate heat sink using fasteners. The mounting cup, which surrounds the electromagnetic device, in combination with the potting resin provides improved thermal transfer to the plate heat sink, as well as providing resistance to vibration and shocks.

  2. MR findings of facial nerve on oblique sagittal MRI using TMJ surface coil: normal vs peripheral facial nerve palsy

    International Nuclear Information System (INIS)

    Park, Yong Ok; Lee, Myeong Jun; Lee, Chang Joon; Yoo, Jeong Hyun

    2000-01-01

    To evaluate the findings of normal facial nerve, as seen on oblique sagittal MRI using a TMJ (temporomandibular joint) surface coil, and then to evaluate abnormal findings of peripheral facial nerve palsy. We retrospectively reviewed the MR findings of 20 patients with peripheral facial palsy and 50 normal facial nerves of 36 patients without facial palsy. All underwent oblique sagittal MRI using a T MJ surface coil. We analyzed the course, signal intensity, thickness, location, and degree of enhancement of the facial nerve. According to the angle made by the proximal parotid segment on the axis of the mastoid segment, course was classified as anterior angulation (obtuse and acute, or buckling), straight and posterior angulation. Among 50 normal facial nerves, 24 (48%) were straight, and 23 (46%) demonstrated anterior angulation; 34 (68%) showed iso signal intensity on T1W1. In the group of patients, course on the affected side was either straight (40%) or showed anterior angulation (55%), and signal intensity in 80% of cases was isointense. These findings were similar to those in the normal group, but in patients with post-traumatic or post-operative facial palsy, buckling, of course, appeared. In 12 of 18 facial palsy cases (66.6%) in which contrast materials were administered, a normal facial nerve of the opposite facial canal showed mild enhancement on more than one segment, but on the affected side the facial nerve showed diffuse enhancement in all 14 patients with acute facial palsy. Eleven of these (79%) showed fair or marked enhancement on more than one segment, and in 12 (86%), mild enhancement of the proximal parotid segment was noted. Four of six chronic facial palsy cases (66.6%) showed atrophy of the facial nerve. When oblique sagittal MR images are obtained using a TMJ surface coil, enhancement of the proximal parotid segment of the facial nerve and fair or marked enhancement of at least one segment within the facial canal always suggests pathology of

  3. Surface biology of collagen scaffold explains blocking of wound contraction and regeneration of skin and peripheral nerves.

    Science.gov (United States)

    Yannas, I V; Tzeranis, D; So, P T

    2015-12-23

    We review the details of preparation and of the recently elucidated mechanism of biological (regenerative) activity of a collagen scaffold (dermis regeneration template, DRT) that has induced regeneration of skin and peripheral nerves (PN) in a variety of animal models and in the clinic. DRT is a 3D protein network with optimized pore size in the range 20-125 µm, degradation half-life 14 ± 7 d and ligand densities that exceed 200 µM α1β1 or α2β1 ligands. The pore has been optimized to allow migration of contractile cells (myofibroblasts, MFB) into the scaffold and to provide sufficient specific surface for cell-scaffold interaction; the degradation half-life provides the required time window for satisfactory binding interaction of MFB with the scaffold surface; and the ligand density supplies the appropriate ligands for specific binding of MFB on the scaffold surface. A dramatic change in MFB phenotype takes place following MFB-scaffold binding which has been shown to result in blocking of wound contraction. In both skin wounds and PN wounds the evidence has shown clearly that contraction blocking by DRT is followed by induction of regeneration of nearly perfect organs. The biologically active structure of DRT is required for contraction blocking; well-matched collagen scaffold controls of DRT, with structures that varied from that of DRT, have failed to induce regeneration. Careful processing of collagen scaffolds is required for adequate biological activity of the scaffold surface. The newly understood mechanism provides a relatively complete paradigm of regenerative medicine that can be used to prepare scaffolds that may induce regeneration of other organs in future studies.

  4. Influence of an irregular surface and low light on the step variability of patients with peripheral neuropathy during level gait.

    Science.gov (United States)

    Thies, Sibylle B; Richardson, James K; Demott, Trina; Ashton-Miller, James A

    2005-08-01

    Patients with peripheral neuropathy (PN) report greater difficulty walking on irregular surfaces with low light (IL) than on flat surfaces with regular lighting (FR). We tested the primary hypothesis that older PN patients would demonstrate greater step width and step width variability under IL conditions than under FR conditions. Forty-two subjects (22 male, 20 female: mean +/- S.D.: 64.7 +/- 9.8 years) with PN underwent history, physical examination, and electrodiagnostic testing. Subjects were asked to walk 10 m at a comfortable speed while kinematic and force data were measured at 100 Hz using optoelectronic markers and foot switches. Ten trials were conducted under both IL and FR conditions. Step width, time, length, and speed were calculated with a MATLAB algorithm, with the standard deviation serving as the measure of variability. The results showed that under IL, as compared to FR, conditions subjects demonstrated greater step width (197.1 +/- 40.8 mm versus 180.5 +/- 32.4 mm; P < 0.001) and step width variability (40.4 +/- 9.0 mm versus 34.5 +/- 8.4 mm; P < 0.001), step time and its variability (P < 0.001 and P = 0.003, respectively), and step length variability (P < 0.001). Average step length and gait speed decreased under IL conditions (P < 0.001 for both). Step width variability and step time variability correlated best under IL conditions with a clinical measure of PN severity and fall history, respectively. We conclude that IL conditions cause PN patients to increase the variability of their step width and other gait parameters.

  5. Liner mounting assembly

    Science.gov (United States)

    Halila, Ely E. (Inventor)

    1994-01-01

    A mounting assembly includes an annular supporting flange disposed coaxially about a centerline axis which has a plurality of circumferentially spaced apart supporting holes therethrough. An annular liner is disposed coaxially with the supporting flange and includes a plurality of circumferentially spaced apart mounting holes aligned with respective ones of the supporting holes. Each of a plurality of mounting pins includes a proximal end fixedly joined to the supporting flange through a respective one of the supporting holes, and a distal end disposed through a respective one of the liner mounting holes for supporting the liner to the supporting flange while unrestrained differential thermal movement of the liner relative to the supporting flange.

  6. Effects of emission reductions at the Hayden powerplant on precipitation, snowpack, and surface-water chemistry in the Mount Zirkel Wilderness Area, Colorado, 1995-2003

    Science.gov (United States)

    Mast, M. Alisa; Campbell, Donald H.; Ingersoll, George P.

    2005-01-01

    Precipitation, snowpack, and surface-water samples collected during 1995-2003 were analyzed to evaluate the effects of emission reductions at the Hayden powerplant on water chemistry in the Mount Zirkel Wilderness Area. The Hayden powerplant, one of two large coal-fired powerplants in the Yampa Valley, was retrofitted with control systems during late 1998 and 1999 to reduce emissions of sulfur dioxide and nitrogen oxide--the primary precursors of haze and acidic precipitation. The U.S. Geological Survey, in cooperation with the Colorado Department of Public Health and Environment, evaluated three water-chemistry data sets: wet-only precipitation chemistry from the National Atmospheric Deposition Program, snowpack chemistry from the Rocky Mountain snowpack network, and surface-water chemistry from a U.S. Geological Survey long-term lakes monitoring program. Concentrations and deposition rates of selected constituents were compared for the periods before and after emission reductions at the Hayden powerplant. Data collected during 1995-98 were used to represent the pre-control period, and data collected during 2000-2003 were used to represent the post-control period. Ten stations in the National Atmospheric Deposition Program were evaluated including two that were directly downwind from the Hayden powerplant (Dry Lake and Buffalo Pass) and eight that were upwind or more distant (more than 100 kilometers) from the powerplant. Precipitation amount at all 10 precipitation stations was lower in the post-control period than the pre-control period as a result of a regional drought that persisted during the post-control period. In contrast to precipitation amount, there was no consistent pattern of change in sulfate concentrations between periods, indicating that the drought did not have a concentrating effect on sulfate or that trends in regional sulfur dioxide emissions masked its influence. Sulfate concentrations increased at three stations between periods, remained the

  7. Expression of variant surface antigens by Plasmodium falciparum parasites in the peripheral blood of clinically immune pregnant women indicates ongoing placental infection

    DEFF Research Database (Denmark)

    Ofori, Michael F; Staalsoe, Trine; Bam, Victoria

    2003-01-01

    Placenta-sequestered Plasmodium falciparum parasites that cause pregnancy-associated malaria (PAM) in otherwise clinically immune women express distinct variant surface antigens (VSA(PAM)) not expressed by parasites in nonpregnant individuals. We report here that parasites from the peripheral blood...... of clinically immune pregnant women also express VSA(PAM), making them a convenient source of VSA(PAM) expressors for PAM vaccine research....

  8. Mounting apparatus for a nozzle guide vane assembly

    Science.gov (United States)

    Boyd, Gary L.; Shaffer, James E.

    1995-01-01

    The present invention provides a ceramic nozzle guide assembly with an apparatus for mounting it to a metal nozzle case that includes an intermediate ceramic mounting ring. The mounting ring includes a plurality of projections that are received within a plurality of receptacles formed in the nozzle case. The projections of the mounting ring are secured within the receptacles by a ceramic retainer that allows contact between the two components only along arcuate surfaces thus eliminating sliding contact between the components.

  9. Sensor mount assemblies and sensor assemblies

    Science.gov (United States)

    Miller, David H [Redondo Beach, CA

    2012-04-10

    Sensor mount assemblies and sensor assemblies are provided. In an embodiment, by way of example only, a sensor mount assembly includes a busbar, a main body, a backing surface, and a first finger. The busbar has a first end and a second end. The main body is overmolded onto the busbar. The backing surface extends radially outwardly relative to the main body. The first finger extends axially from the backing surface, and the first finger has a first end, a second end, and a tooth. The first end of the first finger is disposed on the backing surface, and the tooth is formed on the second end of the first finger.

  10. A dye penetration inspection device for a peripheral annular zone of of a body

    International Nuclear Information System (INIS)

    Gebel, A.; Gemma, A.

    1996-01-01

    The device is composed of: a transverse annular rail track that is attached to the peripheral surface of the body, a guided cart moving on the track, and various equipment mounted on the cart including nozzles for spraying the dye liquid, a dye cleaning liquid and a developer product, and drying means and remote viewing means. Remote control means are also used to control cart motion and spraying, cleaning and drying sequences

  11. Internally Mounting Strain Gages

    Science.gov (United States)

    Jett, J. R., Jr.

    1984-01-01

    Technique for mounting strain gages inside bolt or cylinder simultaneously inserts gage, attached dowel segment, and length of expandable tubing. Expandable tubing holds gage in place while adhesive cures, assuring even distribution of pressure on gage and area gaged.

  12. Mounting for ceramic scroll

    Science.gov (United States)

    Petty, Jack D.

    1993-01-01

    A mounting for a ceramic scroll on a metal engine block of a gas turbine engine includes a first ceramic ring and a pair of cross key connections between the first ceramic ring, the ceramic scroll, and the engine block. The cross key connections support the scroll on the engine block independent of relative radial thermal growth and for bodily movement toward an annular mounting shoulder on the engine. The scroll has an uninterrupted annular shoulder facing the mounting shoulder on the engine block. A second ceramic ring is captured between mounting shoulder and the uninterrupted shoulder on the scroll when the latter is bodily shifted toward the mouting shoulder to define a gas seal between the scroll and the engine block.

  13. The timing and cause of glacial activity during the last glacial in central Tibet based on 10Be surface exposure dating east of Mount Jaggang, the Xainza range

    Science.gov (United States)

    Dong, Guocheng; Zhou, Weijian; Yi, Chaolu; Fu, Yunchong; Zhang, Li; Li, Ming

    2018-04-01

    Mountain glaciers are sensitive to climate change, and can provide valuable information for inferring former climates on the Tibetan Plateau (TP). The increasing glacial chronologies indicate that the timing of the local Last Glacial Maximum (LGM) recorded across the TP is asynchronous, implying different local influences of the mid-latitude westerlies and Asian Summer Monsoon in triggering glacier advances. However, the well-dated sites are still too few, especially in the transition zone between regions controlled by the two climate systems. Here we present detailed last glacial chronologies for the Mount Jaggang area, in the Xainza range, central Tibet, with forty-three apparent 10Be exposure-ages ranging from 12.4 ± 0.8 ka to 61.9 ± 3.8 ka. These exposure-ages indicate that at least seven glacial episodes occurred during the last glacial cycle east of Mount Jaggang. These include: a local LGM that occurred at ∼61.9 ± 3.8 ka, possibly corresponding to Marine Isotope Stage 4 (MIS 4); subsequent glacial advances at ∼43.2 ± 2.6 ka and ∼35.1 ± 2.1 ka during MIS 3; one glacial re-advance/standstill at MIS3/2 transition (∼29.8 ± 1.8 ka); and three glacial re-advances/standstills that occurred following MIS 3 at ∼27.9 ± 1.7 ka, ∼21.8 ± 1.3 ka, and ∼15.1 ± 0.9 ka. The timing of these glacial activities is roughly in agreement with North Atlantic millennial-scale climate oscillations (Heinrich events), suggesting the potential correlations between these abrupt climate changes and glacial fluctuations in the Mount Jaggang area. The successively reduced glacial extent might have resulted from an overall decrease in Asian Summer Monsoon intensity over this timeframe.

  14. Peripheral reactions

    International Nuclear Information System (INIS)

    Greiner, D.

    1978-01-01

    Peripheral collisions, that is, collisions involving a small amount of overlap of nuclear matter, are discussed including inclusive interactions, the magnitude of the peripheral cross section, fragmentation, a compilation of experiments and available data, limiting fragmentation, factorization, some models, fragment momentum distributions, and future research directions

  15. Transducer-Mounting Fixture

    Science.gov (United States)

    Spiegel, Kirk W.

    1990-01-01

    Transducer-mounting fixture holds transducer securely against stud. Projects only slightly beyond stud after installation. Flanged transducer fits into fixture when hinged halves open. When halves reclosed, fixture tightened onto threaded stud until stud makes contact with transducer. Knurled area on fixture aids in tightening fixture on stud.

  16. Inkjet printed paper based frequency selective surfaces and skin mounted RFID tags : the interrelation between silver nanoparticle ink, paper substrate and low temperature sintering technique

    NARCIS (Netherlands)

    Sanchez-Romaquera, V.; Wïnscher, S.; Turki, B.M.; Abbel, R.J.; Barbosa, S.; Tate, D.J.; Oyeka, D.; Batchelor, J.C.; Parker, E.A.; Schubert, U.S.; Yeates, S.G.

    2015-01-01

    Inkjet printing of functional frequency selective surfaces (FSS) and radio frequency identification (RFID) tags on commercial paper substrates using silver nanoparticle inks sintered using low temperature thermal, plasma and photonic techniques is reported. Printed and sintered FSS devices

  17. Scintillation crystal mounting apparatus

    International Nuclear Information System (INIS)

    Engdahl, L.W.; Deans, A.J.

    1982-01-01

    An improved detector head for a gamma camera is disclosed. The detector head includes a housing and a detector assembly mounted within the housing. Components of the detector assembly include a crystal sub-assembly, a phototube array, and a light pipe between the phototube array and crystal sub-assembly. The invention provides a unique structure for maintaining the phototubes in optical relationship with the light pipe and preventing the application of forces that would cause the camera's crystal to crack

  18. Characterization of Engine Mount Elastomers

    National Research Council Canada - National Science Library

    Szabo, Jeffrey P

    2005-01-01

    As part of a project to develop methods for modelling the performance of engine mounts, several oil resistant alternative materials were prepared, and compared to conventional materials from mounts...

  19. Fixture For Mounting A Pressure Sensor

    Science.gov (United States)

    Cagle, Christopher M.

    1995-01-01

    Fixture for mounting pressure sensor in aerodynamic model simplifies task of removal and replacement of sensor in event sensor becomes damaged. Makes it unnecessary to dismantle model. Also minimizes any change in aerodynamic characteristics of model in event of replacement. Removable pressure sensor installed in fixture in wall of model. Wires from sensor pass through channel under surface.

  20. Flush-mounting technique for composite beams

    Science.gov (United States)

    Harman, T. C.; Kay, B. F.

    1980-01-01

    Procedure permits mounting of heavy parts to surface of composite beams without appreciably weakening beam web. Web is split and held apart in region where attachment is to be made by lightweight precast foam filler. Bolt hole penetrates foam rather than web, and is secured by barrelnut in transverse bushing through web.

  1. Photovoltaic module mounting clip with integral grounding

    Science.gov (United States)

    Lenox, Carl J.

    2010-08-24

    An electrically conductive mounting/grounding clip, usable with a photovoltaic (PV) assembly of the type having an electrically conductive frame, comprises an electrically conductive body. The body has a central portion and first and second spaced-apart arms extending from the central portion. Each arm has first and second outer portions with frame surface-disrupting element at the outer portions.

  2. Expression of Cellular Isoform of Prion Protein on the Surface of Peripheral Blood Lymphocytes Among Women Exposed to Low Doses of Ionizing Radiation

    International Nuclear Information System (INIS)

    Klucinski, P.; Martirosian, G.; Mazur, B.; Kaufman, J.; Hrycek, A.; Masluch, E.; Cieslik, P.

    2007-01-01

    Ionizing radiation affect the expression of adhesive and co-stimulation molecules in lymphocytes. The objective of this study was to determinate the effect of low doses of ionizing radiation on the expression of prion protein PrPc on the surface peripheral blood lymphocytes in the women operating X-ray equipment. In female workers and persons of the control group the PrPc expression on CD3 (T-lymphocytes), Cd4 (T-helper), CD8 (T-cytotoxic) and CD19 (B- lymphocytes), were tested. We conclude that in women operating X-ray equipment the relationship between low doses of ionizing radiation and expression of PrPc on lymphocytes does exist concerning CD3, CD4 and CD lymphocytes. (author)

  3. Mounting system for optical frequency reference cavities

    Science.gov (United States)

    Notcutt, Mark (Inventor); Hall, John L. (Inventor); Ma, Long-Sheng (Inventor)

    2008-01-01

    A technique for reducing the vibration sensitivity of laser-stabilizing optical reference cavities is based upon an improved design and mounting method for the cavity, wherein the cavity is mounted vertically. It is suspended at one plane, around the spacer cylinder, equidistant from the mirror ends of the cavity. The suspension element is a collar of an extremely low thermal expansion coefficient material, which surrounds the spacer cylinder and contacts it uniformly. Once the collar has been properly located, it is cemented in place so that the spacer cylinder is uniformly supported and does not have to be squeezed at all. The collar also includes a number of cavities partially bored into its lower flat surface, around the axial bore. These cavities are support points, into which mounting base pins will be inserted. Hence the collar is supported at a minimum of three points.

  4. Hole-thru-laminate mounting supports for photovoltaic modules

    Science.gov (United States)

    Wexler, Jason; Botkin, Jonathan; Culligan, Matthew; Detrick, Adam

    2015-02-17

    A mounting support for a photovoltaic module is described. The mounting support includes a pedestal having a surface adaptable to receive a flat side of a photovoltaic module laminate. A hole is disposed in the pedestal, the hole adaptable to receive a bolt or a pin used to couple the pedestal to the flat side of the photovoltaic module laminate.

  5. [Does the mounting of gastrointestinal biopsies on millipore filter contribute to an improved section quality?

    DEFF Research Database (Denmark)

    Asmussen, L.; Bernstein, I.; Matzen, P.

    2009-01-01

    orientation, GIB is occasionally mounted on millipore filter (MF) in an attempt to place the deep cut side onto the MF. The importance of this technique for section quality is evaluated in this study. MATERIAL AND METHOD: The material comprised three consecutive series of GIB (60 gastric, duodenal......, and colorectal GIB, respectively). Sections were grouped in MF-mounted versus non-mounted GIB, the proportion of fully acceptable sections among mounted versus non-mounted GIB was recorded. RESULTS: 77.2% of all GIBs were MF-mounted. 33.1% of mounted GIBs versus 48.8% of non-mounted GIBs were assessed as fully...... acceptable sections. The differences between these figures are not statistically significant. 41.7% of the mounted GIBs were placed with the mucosal surface facing the MF, which entails a risk of damaging the tissue. CONCLUSION: MF-mounting of GIB did not contribute to section quality. Since the handling...

  6. Synergistic use of Lagrangian dispersion and radiative transfer modelling with satellite and surface remote sensing measurements for the investigation of volcanic plumes: the Mount Etna eruption of 25–27 October 2013

    Directory of Open Access Journals (Sweden)

    P. Sellitto

    2016-06-01

    Full Text Available In this paper we combine SO2 and ash plume dispersion modelling with satellite and surface remote sensing observations to study the regional influence of a relatively weak volcanic eruption from Mount Etna on the optical and micro-physical properties of Mediterranean aerosols. We analyse the Mount Etna eruption episode of 25–27 October 2013. The evolution of the plume along the trajectory is investigated by means of the FLEXible PARTicle Lagrangian dispersion (FLEXPART model. The satellite data set includes true colour images, retrieved values of volcanic SO2 and ash, estimates of SO2 and ash emission rates derived from MODIS (MODerate resolution Imaging Spectroradiometer observations and estimates of cloud top pressure from SEVIRI (Spinning Enhanced Visible and InfraRed Imager. Surface remote sensing measurements of aerosol and SO2 made at the ENEA Station for Climate Observations (35.52° N, 12.63° E; 50 m a.s.l. on the island of Lampedusa are used in the analysis. The combination of these different data sets suggests that SO2 and ash, despite the initial injection at about 7.0 km altitude, reached altitudes around 10–12 km and influenced the column average aerosol particle size distribution at a distance of more than 350 km downwind. This study indicates that even a relatively weak volcanic eruption may produce an observable effect on the aerosol properties at the regional scale. The impact of secondary sulfate particles on the aerosol size distribution at Lampedusa is discussed and estimates of the clear-sky direct aerosol radiative forcing are derived. Daily shortwave radiative forcing efficiencies, i.e. radiative forcing per unit AOD (aerosol optical depth, are calculated with the LibRadtran model. They are estimated between −39 and −48 W m−2 AOD−1 at the top of the atmosphere and between −66 and −49 W m−2 AOD−1 at the surface, with the variability in the estimates mainly depending on the

  7. Assessing the Contribution of the CFRP Strip of Bearing the Applied Load Using Near-Surface Mounted Strengthening Technique with Innovative High-Strength Self-Compacting Cementitious Adhesive (IHSSC-CA

    Directory of Open Access Journals (Sweden)

    Alyaa Mohammed

    2018-01-01

    Full Text Available Efficient transfer of load between concrete substrate and fibre reinforced polymer (FRP by the bonding agent is the key factor in any FRP strengthening system. An innovative high-strength self-compacting non-polymer cementitious adhesive (IHSSC-CA was recently developed by the authors and has been used in a number of studies. Graphene oxide and cementitious materials are used to synthesise the new adhesive. The successful implementation of IHSSC-CA significantly increases carbon FRP (CFRP strip utilization and the load-bearing capacity of the near-surface mounted (NSM CFRP strengthening system. A number of tests were used to inspect the interfacial zone in the bonding area of NSM CFRP strips, including physical examination, pore structure analysis, and three-dimensional laser profilometery analysis. It was deduced from the physical inspection of NSM CFRP specimens made with IHSSC-CA that a smooth surface for load transfer was found in the CFRP strip without stress concentrations in some local regions. A smooth surface of the adhesive layer is very important for preventing localized brittle failure in the concrete. The pore structure analysis also confirmed that IHSSC-CA has better composite action between NSM CFRP strips and concrete substrate than other adhesives, resulting in the NSM CFRP specimens made with IHSSC-CA sustaining a greater load. Finally, the results of three-dimensional laser profilometery revealed a greater degree of roughness and less deformation on the surface of the CFRP strip when IHSSC-CA was used compared to other adhesives.

  8. Effect of cardiopulmonary bypass on beta adrenergic receptor-adenylate cyclase system on surfaces of peripheral lymphocytes.

    Science.gov (United States)

    Luo, A; Tian, Y; Jin, S

    2000-01-01

    The experimental results showed that the level of CAMP, the ratio of cAPM to cGMP, IL-2R expression and IL-2 production in vitro in lymphocytes immediate and 2 weeks after cardiopulmonary bypass (CPB) were significantly lower than those before anesthetics in the patients undergoing cardiac surgery with CPB. These findings suggested that CPB could cause serious damage to adrenergic beta receptor-adenylate cyclase system on circulating lymphocytes surfaces, which might be one of the mechanisms resulting in immunosuppression after open heart surgery with CPB.

  9. Methods and apparatus for radially compliant component mounting

    Science.gov (United States)

    Bulman, David Edward [Cincinnati, OH; Darkins, Jr., Toby George; Stumpf, James Anthony [Columbus, IN; Schroder, Mark S [Greenville, SC; Lipinski, John Joseph [Simpsonville, SC

    2012-03-27

    Methods and apparatus for a mounting assembly for a liner of a gas turbine engine combustor are provided. The combustor includes a combustor liner and a radially outer annular flow sleeve. The mounting assembly includes an inner ring surrounding a radially outer surface of the liner and including a plurality of axially extending fingers. The mounting assembly also includes a radially outer ring coupled to the inner ring through a plurality of spacers that extend radially from a radially outer surface of the inner ring to the outer ring.

  10. Resilient mounting systems in buildings

    NARCIS (Netherlands)

    Breeuwer, R.; Tukker, J.C.

    1976-01-01

    The basic elements of resilient mounting systems are described and various measures for quantifying the effect of such systems defined. Using electrical analogue circuits, the calculation of these measures is illustrated. With special reference to resilient mounting systems in buildings, under

  11. Mount Rainier National Park

    Science.gov (United States)

    Hoffman, Robert; Woodward, Andrea; Haggerty, Patricia K.; Jenkins, Kurt J.; Griffin, Paul C.; Adams, Michael J.; Hagar, Joan; Cummings, Tonnie; Duriscoe, Dan; Kopper, Karen; Riedel, Jon; Samora, Barbara; Marin, Lelaina; Mauger, Guillaume S.; Bumbaco, Karen; Littell, Jeremy S.

    2014-01-01

    Natural Resource Condition Assessments (NRCAs) evaluate current conditions for a subset of natural resources and resource indicators in national parks. NRCAs also report on trends in resource condition (when possible), identify critical data gaps, and characterize a general level of confidence for study findings. The resources and indicators emphasized in a given project depend on the park’s resource setting, status of resource stewardship planning and science in identifying high-priority indicators, and availability of data and expertise to assess current conditions for a variety of potential study resources and indicators. Although the primary objective of NRCAs is to report on current conditions relative to logical forms of reference conditions and values, NRCAs also report on trends, when appropriate (i.e., when the underlying data and methods support such reporting), as well as influences on resource conditions. These influences may include past activities or conditions that provide a helpful context for understanding current conditions and present-day threats and stressors that are best interpreted at park, watershed, or landscape scales (though NRCAs do not report on condition status for land areas and natural resources beyond park boundaries). Intensive cause-andeffect analyses of threats and stressors, and development of detailed treatment options, are outside the scope of NRCAs. It is also important to note that NRCAs do not address resources that lack sufficient data for assessment. For Mount Rainier National Park, this includes most invertebrate species and many other animal species that are subject to significant stressors from climate change and other anthropogenic sources such as air pollutants and recreational use. In addition, we did not include an analysis of the physical hydrology associated with streams (such as riverine landforms, erosion and aggradation which is significant in MORA streams), due to a loss of staff expertise from the USGS

  12. Photovoltaic array mounting apparatus, systems, and methods

    Science.gov (United States)

    West, John Raymond; Atchley, Brian; Hudson, Tyrus Hawkes; Johansen, Emil

    2014-12-02

    An apparatus for mounting a photovoltaic (PV) module on a surface, including a support with an upper surface, a lower surface, tabs, one or more openings, and a clip comprising an arm and a notch, where the apparatus resists wind forces and seismic forces and creates a grounding electrical bond between the PV module, support, and clip. The invention further includes a method for installing PV modules on a surface that includes arranging supports in rows along an X axis and in columns along a Y axis on a surface such that in each row the distance between two neighboring supports does not exceed the length of the longest side of a PV module and in each column the distance between two neighboring supports does not exceed the length of the shortest side of a PV module.

  13. Mount Oku, Cameroon Volcanic Line

    African Journals Online (AJOL)

    and continental sectors especially for trace elements in basalts. ... continental sector of the trend is a complex .... values higher than those of HIMU but is within ...... (Mount Cameroon, Central Africa): petrogenetic implications. Miner. Petrol.,.

  14. Solar panel parallel mounting configuration

    Science.gov (United States)

    Mutschler, Jr., Edward Charles (Inventor)

    1998-01-01

    A spacecraft includes a plurality of solar panels interconnected with a power coupler and an electrically operated device to provide power to the device when the solar cells are insolated. The solar panels are subject to bending distortion when entering or leaving eclipse. Spacecraft attitude disturbances are reduced by mounting each of the solar panels to an elongated boom made from a material with a low coefficient of thermal expansion, so that the bending of one panel is not communicated to the next. The boom may be insulated to reduce its bending during changes in insolation. A particularly advantageous embodiment mounts each panel to the boom with a single mounting, which may be a hinge. The single mounting prevents transfer of bending moments from the panel to the boom.

  15. Mounting clips for panel installation

    Science.gov (United States)

    Cavieres, Andres; Al-Haddad, Tristan; Goodman, Joseph

    2017-07-11

    A photovoltaic panel mounting clip comprising a base, central indexing tabs, flanges, lateral indexing tabs, and vertical indexing tabs. The mounting clip removably attaches one or more panels to a beam or the like structure, both mechanically and electrically. It provides secure locking of the panels in all directions, while providing guidance in all directions for accurate installation of the panels to the beam or the like structure.

  16. Apparatus for mounting crystal

    Science.gov (United States)

    Longeway, Paul A.

    1985-01-01

    A thickness monitor useful in deposition or etching reactor systems comprising a crystal-controlled oscillator in which the crystal is deposited or etched to change the frequency of the oscillator. The crystal rests within a thermally conductive metallic housing and arranged to be temperature controlled. Electrode contacts are made to the surface primarily by gravity force such that the crystal is substantially free of stress otherwise induced by high temperature.

  17. The head-mounted microscope.

    Science.gov (United States)

    Chen, Ting; Dailey, Seth H; Naze, Sawyer A; Jiang, Jack J

    2012-04-01

    Microsurgical equipment has greatly advanced since the inception of the microscope into the operating room. These advancements have allowed for superior surgical precision and better post-operative results. This study focuses on the use of the Leica HM500 head-mounted microscope for the operating phonosurgeon. The head-mounted microscope has an optical zoom from 2× to 9× and provides a working distance from 300 mm to 700 mm. The headpiece, with its articulated eyepieces, adjusts easily to head shape and circumference, and offers a focus function, which is either automatic or manually controlled. We performed five microlaryngoscopic operations utilizing the head-mounted microscope with successful results. By creating a more ergonomically favorable operating posture, a surgeon may be able to obtain greater precision and success in phonomicrosurgery. Phonomicrosurgery requires the precise manipulation of long-handled cantilevered instruments through the narrow bore of a laryngoscope. The head-mounted microscope shortens the working distance compared with a stand microscope, thereby increasing arm stability, which may improve surgical precision. Also, the head-mounted design permits flexibility in head position, enabling operator comfort, and delaying musculoskeletal fatigue. A head-mounted microscope decreases the working distance and provides better ergonomics in laryngoscopic microsurgery. These advances provide the potential to promote precision in phonomicrosurgery. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.

  18. Inboard seal mounting

    Science.gov (United States)

    Hayes, John R. (Inventor)

    1983-01-01

    A regenerator assembly for a gas turbine engine has a hot side seal assembly formed in part by a cast metal engine block having a seal recess formed therein that is configured to supportingly receive ceramic support blocks including an inboard face thereon having a regenerator seal face bonded thereto. A pressurized leaf seal is interposed between the ceramic support block and the cast metal engine block to bias the seal wear face into sealing engagement with a hot side surface of a rotary regenerator matrix.

  19. Solar panel truss mounting systems and methods

    Energy Technology Data Exchange (ETDEWEB)

    Al-Haddad, Tristan Farris; Cavieres, Andres; Gentry, Russell; Goodman, Joseph; Nolan, Wade; Pitelka, Taylor; Rahimzadeh, Keyan; Brooks, Bradley; Lohr, Joshua; Crooks, Ryan; Porges, Jamie; Rubin, Daniel

    2016-06-28

    An exemplary embodiment of the present invention provides a solar panel truss mounting system comprising a base and a truss assembly coupled to the base. The truss assembly comprises a first panel rail mount, second panel rail mount parallel to the first panel rail mount, base rail mount parallel to the first and second panel rail mounts, and a plurality of support members. A first portion of the plurality of support members extends between the first and second panel rail mounts. A second portion of the plurality of support members extends between the first panel rail mount and the base rail mount. A third portion of the plurality of support members extends between the second panel rail mount and the base rail mount. The system can further comprise a plurality of connectors for coupling a plurality of photovoltaic solar panels to the truss assembly.

  20. Solar panel truss mounting systems and methods

    Energy Technology Data Exchange (ETDEWEB)

    Al-Haddad, Tristan Farris; Cavieres, Andres; Gentry, Russell; Goodman, Joseph; Nolan, Wade; Pitelka, Taylor; Rahimzadeh, Keyan; Brooks, Bradley; Lohr, Joshua; Crooks, Ryan; Porges, Jamie; Rubin, Daniel

    2018-01-30

    An exemplary embodiment of the present invention provides a solar panel truss mounting system comprising a base and a truss assembly coupled to the base. The truss assembly comprises a first panel rail mount, second panel rail mount parallel to the first panel rail mount, base rail mount parallel to the first and second panel rail mounts, and a plurality of support members. A first portion of the plurality of support members extends between the first and second panel rail mounts. A second portion of the plurality of support members extends between the first panel rail mount and the base rail mount. A third portion of the plurality of support members extends between the second panel rail mount and the base rail mount. The system can further comprise a plurality of connectors for coupling a plurality of photovoltaic solar panels to the truss assembly.

  1. Solar panel truss mounting systems and methods

    Science.gov (United States)

    Al-Haddad, Tristan Farris; Cavieres, Andres; Gentry, Russell; Goodman, Joseph; Nolan, Wade; Pitelka, Taylor; Rahimzadeh, Keyan; Brooks, Bradley; Lohr, Joshua; Crooks, Ryan; Porges, Jamie; Rubin, Daniel

    2015-10-20

    An exemplary embodiment of the present invention provides a solar panel truss mounting system comprising a base and a truss assembly coupled to the base. The truss assembly comprises a first panel rail mount, second panel rail mount parallel to the first panel rail mount, base rail mount parallel to the first and second panel rail mounts, and a plurality of support members. A first portion of the plurality of support members extends between the first and second panel rail mounts. A second portion of the plurality of support members extends between the first panel rail mount and the base rail mount. A third portion of the plurality of support members extends between the second panel rail mount and the base rail mount. The system can further comprise a plurality of connectors for coupling a plurality of photovoltaic solar panels to the truss assembly.

  2. Peripheral ossifying fibroma

    Directory of Open Access Journals (Sweden)

    Ameet Mani

    2010-01-01

    Full Text Available The peripheral ossifying fibroma (POF is an exophytic gingival mass of fibrous connective tissue covered with a surface epithelium associated with the formation of randomly dispersed foci of a mineralized product consisting of bone, cementum-like tissue, or dystrophic calcifications having a recurrent rate of nearly 20%. It is one of the most common reactive gingival lesions, which have often been called by the generic term "epulis." This case report describes the clinical and histopathological findings of POF, its differential diagnosis, and treatment.

  3. Mounted Smartphones as Measurement and Control Platforms for Motor-Based Laboratory Test-Beds

    OpenAIRE

    Jared A. Frank; Anthony Brill; Vikram Kapila

    2016-01-01

    Laboratory education in science and engineering often entails the use of test-beds equipped with costly peripherals for sensing, acquisition, storage, processing, and control of physical behavior. However, costly peripherals are no longer necessary to obtain precise measurements and achieve stable feedback control of test-beds. With smartphones performing diverse sensing and processing tasks, this study examines the feasibility of mounting smartphones directly to test-beds to exploit their em...

  4. Mount Zirkel Wilderness and vicinity, Colorado

    International Nuclear Information System (INIS)

    Snyder, G.L.; Patten, L.L.

    1984-01-01

    Several areas of metallic and nonmetallic mineralization have been identified from surface occurrences within the Mount Zirkel Wilderness and vicinity, Colorado. Three areas of probable copper-lead-zinc-silver-gold resource potential, two areas of probable chrome-platinum resource potential, four areas of probable uranium-thorium resource potential, two areas of probable molybdenum resource potential, and one area of probable fluorspar potential were identified by studies in 1965-1973 by the USGS and USBM. No potential for fossil fuel or geothermal resources was identified

  5. Mounting clips for panel installation

    Science.gov (United States)

    Cavieres, Andres; Al-Haddad, Tristan; Goodman, Joseph; Valdes, Francisco

    2017-02-14

    An exemplary mounting clip for removably attaching panels to a supporting structure comprises a base, spring locking clips, a lateral flange, a lever flange, and a spring bonding pad. The spring locking clips extend upwardly from the base. The lateral flange extends upwardly from a first side of the base. The lateral flange comprises a slot having an opening configured to receive at least a portion of one of the one or more panels. The lever flange extends outwardly from the lateral flange. The spring bonding flange extends downwardly from the lever flange. At least a portion of the first spring bonding flange comprises a serrated edge for gouging at least a portion of the one or more panels when the one or more panels are attached to the mounting clip to electrically and mechanically couple the one or more panels to the mounting clip.

  6. Human recombinant antibodies against Plasmodium falciparum merozoite surface protein 3 cloned from peripheral blood leukocytes of individuals with immunity to malaria demonstrate antiparasitic properties

    DEFF Research Database (Denmark)

    Lundquist, Rasmus; Nielsen, Leif Kofoed; Jafarshad, Ali

    2006-01-01

    against MSP-3 residues 194 to 257 (MSP-3(194-257)) on the molecular level. mRNA from peripheral blood leukocytes from clinically immune individuals was used as a source of Fab (fragment antibody) genes. A Fab-phage display library was made, and three distinct antibodies designated RAM1, RAM2, and RAM3...

  7. Mounting power cables on SOLEIL

    CERN Multimedia

    Laurent Guiraud

    1999-01-01

    The power couplers are mounted on the SOLEIL cryomodule in a clean room. The cryomodule will allow superconducting technology to be used at SOLEIL, the French national synchrotron facility. This work is carried out as part of a collaboration between CERN and CEA Saclay, the French National Atomic Energy Commission.

  8. Shock Mounting for Heavy Machines

    Science.gov (United States)

    Thompson, A. R.

    1984-01-01

    Elastomeric bearings eliminate extraneous forces. Rocket thrust transmitted from motor to load cells via support that absorbs extraneous forces so they do not affect accuracy of thrust measurements. Adapter spoked cone fits over forward end of rocket motor. Shock mounting developed for rocket engines under test used as support for heavy machines, bridges, or towers.

  9. Mount St. Helens aerosol evolution

    Energy Technology Data Exchange (ETDEWEB)

    Oberbeck, V.R.; Farlow, N.H.

    1982-08-01

    Stratospheric aerosol samples were collected using a wire impactor during the year following the eruption of Mount St. Helens. Analysis of samples shows that aerosol volume increased for 6 months due to gas-to-particle conversion and then decreased to background levels in the following 6 months.

  10. Control of Wall Mounting Robot

    DEFF Research Database (Denmark)

    Sloth, Christoffer; Pedersen, Rasmus

    2017-01-01

    This paper presents a method for designing controllers for trajectory tracking with actuator constraints. In particular, we consider a joystick-controlled wall mounting robot called WallMo. In contrast to previous works, a model-free approach is taken to the control problem, where the path...

  11. Intraoperative digital angiography: Peripheral vascular applications

    International Nuclear Information System (INIS)

    Bell, K.; Reifsteck, J.E.; Binet, E.F.; Fleisher, H.J.

    1986-01-01

    Intraoperative digital angiography is the procedure of choice for the peripheral vascular surgeon who wishes to evaluate his results before terminating anesthesia. Two operating suites at the John L. McClellan Memorial Veterans Hospital are equipped with permanent ceiling-mounted Philips C-arm fluoroscopes and share an ADAC 4100 digital angiographic system. In the last 18 months, 40 peripheral vascular intraoperative digital angiographic procedures have been performed, in all but two cases using direct arterial puncture. In 65% of cases, the intraoperative study showed no significant abnormality. In 12.5%, minor abnormalities not requiring reoperation were seen. In 22.5% of cases, the intraoperative digital angiogram revealed a significant abnormality requiring immediate operative revision. None of the patients who underwent reoperation experienced postoperative sequelae. Intraoperative digital angiography is useful in identifying complications of peripheral vascular operations

  12. Fingertip touch improves postural stability in patients with peripheral neuropathy.

    Science.gov (United States)

    Dickstein, R; Shupert, C L; Horak, F B

    2001-12-01

    The purpose of this work was to determine whether fingertip touch on a stable surface could improve postural stability during stance in subjects with somatosensory loss in the feet from diabetic peripheral neuropathy. The contribution of fingertip touch to postural stability was determined by comparing postural sway in three touch conditions (light, heavy and none) in eight patients and eight healthy control subjects who stood on two surfaces (firm or foam) with eyes open or closed. In the light touch condition, fingertip touch provided only somatosensory information because subjects exerted less than 1 N of force with their fingertip to a force plate, mounted on a vertical support. In the heavy touch condition, mechanical support was available because subjects transmitted as much force to the force plate as they wished. In the no touch condition, subjects held the right forefinger above the force plate. Antero-posterior (AP) and medio-lateral (ML) root mean square (RMS) of center of pressure (CoP) sway and trunk velocity were larger in subjects with somatosensory loss than in control subjects, especially when standing on the foam surface. The effects of light and heavy touch were similar in the somatosensory loss and control groups. Fingertip somatosensory input through light touch attenuated both AP and ML trunk velocity as much as heavy touch. Light touch also reduced CoP sway compared to no touch, although the decrease in CoP sway was less effective than with heavy touch, particularly on the foam surface. The forces that were applied to the touch plate during light touch preceded movements of the CoP, lending support to the suggestion of a feedforward mechanism in which fingertip inputs trigger the activation of postural muscles for controlling body sway. These results have clinical implications for understanding how patients with peripheral neuropathy may benefit from a cane for postural stability in stance.

  13. Galvanic coupling effects for module-mounting elements of ground-mounted photovoltaic power station

    Directory of Open Access Journals (Sweden)

    Pierozynski Boguslaw

    2017-12-01

    Full Text Available This communication reports on the concerns associated with possible generation of galvanic coupling effects for construction materials that are used to manufacture mounting assemblies for ground-mounted photovoltaic (PV power stations. For this purpose, six macro-corrosion galvanic cells were assembled, including: hot-dip Zn/Magnelis®-coated steel/Al and stainless steel (SS/Al cells. Corrosion experiments involved continuous, ca. three-month exposure of these couplings in 3 wt.% NaCl solution, conducted at room temperature for a stable pH value of around 8. All corrosion cells were subjected to regular assessment of galvanic current-density and potential parameters, where special consideration was given to compare the corrosion behaviour of Zn-coated steel samples with that of Magnelis®-coated electrodes. Characterization of surface condition and elemental composition for examined materials was carried-out by means of SEM and EDX spectroscopy techniques.

  14. Flush mounting of thin film sensors

    Science.gov (United States)

    Moore, Thomas C., Sr. (Inventor)

    1992-01-01

    Flush mounting of a sensor on a surface is provided by first forming a recessed area on the surface. Next, an adhesive bonding mixture is introduced into the recessed area. The adhesive bonding mixture is chosen to provide thermal expansion matching with the surface surrounding the recessed area. A strip of high performance polymeric tape is provided, with the sensor attached to the underside thereof, and the tape is positioned over the recessed area so that it acts as a carrier of the sensor. A shim having flexibility so that it will conform to the surface surrounding the recessed area is placed over the tape, and a vacuum pad is placed over the shim. The area above the surface is then evacuated while holding the sensor flush with the surface during curing of the adhesive bonding mixture. After such curing, the pad, shim, and tape are removed from the sensor, electrical connections for the sensor are provided, after which the remaining space in the recessed area is filled with a polymeric foam.

  15. ATST telescope mount: telescope of machine tool

    Science.gov (United States)

    Jeffers, Paul; Stolz, Günter; Bonomi, Giovanni; Dreyer, Oliver; Kärcher, Hans

    2012-09-01

    The Advanced Technology Solar Telescope (ATST) will be the largest solar telescope in the world, and will be able to provide the sharpest views ever taken of the solar surface. The telescope has a 4m aperture primary mirror, however due to the off axis nature of the optical layout, the telescope mount has proportions similar to an 8 meter class telescope. The technology normally used in this class of telescope is well understood in the telescope community and has been successfully implemented in numerous projects. The world of large machine tools has developed in a separate realm with similar levels of performance requirement but different boundary conditions. In addition the competitive nature of private industry has encouraged development and usage of more cost effective solutions both in initial capital cost and thru-life operating cost. Telescope mounts move relatively slowly with requirements for high stability under external environmental influences such as wind buffeting. Large machine tools operate under high speed requirements coupled with high application of force through the machine but with little or no external environmental influences. The benefits of these parallel development paths and the ATST system requirements are being combined in the ATST Telescope Mount Assembly (TMA). The process of balancing the system requirements with new technologies is based on the experience of the ATST project team, Ingersoll Machine Tools who are the main contractor for the TMA and MT Mechatronics who are their design subcontractors. This paper highlights a number of these proven technologies from the commercially driven machine tool world that are being introduced to the TMA design. Also the challenges of integrating and ensuring that the differences in application requirements are accounted for in the design are discussed.

  16. Tension pneumocephalus: Mount Fuji sign

    Directory of Open Access Journals (Sweden)

    Pulastya Sanyal

    2015-01-01

    Full Text Available A 13-year-old male was operated for a space occupying lesion in the brain. A noncontrast computed tomography scan done in the late postoperative period showed massive subdural air collection causing compression of bilateral frontal lobes with widening of interhemispheric fissure and the frontal lobes acquiring a peak like configuration - causing tension pneumocephalus-"Mount Fuji sign." Tension pneumocephalus occurs when air enters the extradural or intradural spaces in sufficient volume to exert a mass or pressure effect on the brain, leading to brain herniation. Tension pneumocephalus is a surgical emergency, which needs immediate intervention in the form of decompression of the cranial cavity by a burr hole or needle aspiration. The Mount Fuji sign differentiates tension pneumocephalus from pneumocephalus.

  17. Mounting support for a photovoltaic module

    Science.gov (United States)

    Brandt, Gregory Michael; Barsun, Stephan K.; Coleman, Nathaniel T.; Zhou, Yin

    2013-03-26

    A mounting support for a photovoltaic module is described. The mounting support includes a foundation having an integrated wire-way ledge portion. A photovoltaic module support mechanism is coupled with the foundation.

  18. Mounting Thin Samples For Electrical Measurements

    Science.gov (United States)

    Matus, L. G.; Summers, R. L.

    1988-01-01

    New method for mounting thin sample for electrical measurements involves use of vacuum chuck to hold a ceramic mounting plate, which holds sample. Contacts on mounting plate establish electrical connection to sample. Used to make electrical measurements over temperature range from 77 to 1,000 K and does not introduce distortions into magnetic field during Hall measurements.

  19. Propylthiouracil and peripheral neuropathy

    Directory of Open Access Journals (Sweden)

    Valentina Van Boekel

    1992-06-01

    Full Text Available Peripheral neuropathy is a rare manifestation in hyperthyroidism. We describe the neurological manifestations of a 38 year old female with Graves' disease who developed peripheral neuropathy in the course of her treatment with propylthiouracil. After the drug was tapered off, the neurological signs disappeared. Therefore, we call attention for a possible toxic effect on peripheral nervous system caused by this drug.

  20. Eddy current testing system for bottom mounted instrumentation welds

    OpenAIRE

    Kobayashi Noriyasu; Ueno Souichi; Suganuma Naotaka; Oodake Tatsuya; Maehara Takeshi; Kasuya Takashi; Ichikawa Hiroya

    2015-01-01

    The capability of eddy current testing (ECT) for the bottom mounted instrumentation (BMI) weld area of reactor vessel in a pressurized water reactor was demonstrated by the developed ECT system and procedure. It is difficult to position and move the probe on the BMI weld area because the area has complexly curved surfaces. The space coordinates and the normal vectors at the scanning points were calculated as the scanning trajectory of probe based on the measured results of surface shape on th...

  1. Peripheral Neuropathy and Agent Orange

    Science.gov (United States)

    ... Enter ZIP code here Enter ZIP code here Peripheral Neuropathy and Agent Orange VA presumes Veterans' early-onset ... 10 percent disabling by VA's rating regulations. About peripheral neuropathy Peripheral neuropathy is a condition of the peripheral ...

  2. Measurement & Minimization of Mount Induced Strain on Double Crystal Monochromator Crystals

    Science.gov (United States)

    Kelly, J.; Alcock, S. G.

    2013-03-01

    Opto-mechanical mounts can cause significant distortions to monochromator crystals and mirrors if not designed or implemented carefully. A slope measuring profiler, the Diamond-NOM [1], was used to measure the change in tangential slope as a function of crystal clamping configuration and load. A three point mount was found to exhibit the lowest surface distortion (Diamond Light Source.

  3. Gravity and magma induces spreading of Mount Etna volcano revealed by satellite radar interferometry

    Science.gov (United States)

    Lungren, P.; Casu, F.; Manzo, M.; Pepe, A.; Berardino, P.; Sansosti, E.; Lanari, R.

    2004-01-01

    Mount Etna underwent a cycle of eruptive activity over the past ten years. Here we compute ground displacement maps and deformation time series from more than 400 radar interferograms to reveal Mount Etna's average and time varying surface deformation from 1992 to 2001.

  4. A Depth-Based Head-Mounted Visual Display to Aid Navigation in Partially Sighted Individuals

    Science.gov (United States)

    Hicks, Stephen L.; Wilson, Iain; Muhammed, Louwai; Worsfold, John; Downes, Susan M.; Kennard, Christopher

    2013-01-01

    Independent navigation for blind individuals can be extremely difficult due to the inability to recognise and avoid obstacles. Assistive techniques such as white canes, guide dogs, and sensory substitution provide a degree of situational awareness by relying on touch or hearing but as yet there are no techniques that attempt to make use of any residual vision that the individual is likely to retain. Residual vision can restricted to the awareness of the orientation of a light source, and hence any information presented on a wearable display would have to limited and unambiguous. For improved situational awareness, i.e. for the detection of obstacles, displaying the size and position of nearby objects, rather than including finer surface details may be sufficient. To test whether a depth-based display could be used to navigate a small obstacle course, we built a real-time head-mounted display with a depth camera and software to detect the distance to nearby objects. Distance was represented as brightness on a low-resolution display positioned close to the eyes without the benefit focussing optics. A set of sighted participants were monitored as they learned to use this display to navigate the course. All were able to do so, and time and velocity rapidly improved with practise with no increase in the number of collisions. In a second experiment a cohort of severely sight-impaired individuals of varying aetiologies performed a search task using a similar low-resolution head-mounted display. The majority of participants were able to use the display to respond to objects in their central and peripheral fields at a similar rate to sighted controls. We conclude that the skill to use a depth-based display for obstacle avoidance can be rapidly acquired and the simplified nature of the display may appropriate for the development of an aid for sight-impaired individuals. PMID:23844067

  5. Ocean floor mounting of wave energy converters

    Science.gov (United States)

    Siegel, Stefan G

    2015-01-20

    A system for mounting a set of wave energy converters in the ocean includes a pole attached to a floor of an ocean and a slider mounted on the pole in a manner that permits the slider to move vertically along the pole and rotate about the pole. The wave energy converters can then be mounted on the slider to allow adjustment of the depth and orientation of the wave energy converters.

  6. Mounting and Alignment of IXO Mirror Segments

    Science.gov (United States)

    Chan, Kai-Wing; Zhang, William; Evans, Tyler; McClelland, Ryan; Hong, Melinda; Mazzarella, James; Saha, Timo; Jalota, Lalit; Olsen, Lawrence; Byron, Glenn

    2010-01-01

    A suspension-mounting scheme is developed for the IXO (International X-ray Observatory) mirror segments in which the figure of the mirror segment is preserved in each stage of mounting. The mirror, first fixed on a thermally compatible strongback, is subsequently transported, aligned and transferred onto its mirror housing. In this paper, we shall outline the requirement, approaches, and recent progress of the suspension mount processes.

  7. Channel uranium-graphite reactor mounting

    International Nuclear Information System (INIS)

    Polushkin, K.K.; Kuznetsov, A.G.; Zheleznyakov, B.N.

    1981-01-01

    According to theoretical principles of general engineering technology the engineering experience of construction-mounting works at the NPP with channel uranium-graphite reactors is systematized. Main parameters and structural features of the 1000 MW channel uranium-graphite reactors are considered. The succession of mounting operations, premounting equipment and pipelines preparation and mounting works technique are described. The most efficient methods of fitting, welding and machining of reactor elements are recommended. Main problems of technical control service are discussed. A typical netted diagram of main equipment of channel uranium-graphite reactors mounting is given

  8. Ambient noise tomography across Mount St. Helens using a dense seismic array

    KAUST Repository

    Wang, Yadong

    2017-05-08

    We investigated upper crustal structure with data from a dense seismic array deployed around Mount St. Helens for 2 weeks in the summer of 2014. Interstation cross correlations of ambient seismic noise data from the array were obtained, and clear fundamental mode Rayleigh waves were observed between 2.5 and 5 s periods. In addition, higher-mode signals were observed around 2 s period. Frequency-time analysis was applied to measure fundamental mode Rayleigh wave phase velocities, which were used to invert for 2-D phase velocity maps. An azimuth-dependent traveltime correction was implemented to mitigate potential biases introduced due to an inhomogeneous noise source distribution. Reliable phase velocity maps were only obtained between 3 and 4 s periods due to limitations imposed by the array aperture and higher-mode contamination. The phase velocity tomography results, which are sensitive to structure shallower than 6 km depth, reveal an ~10–15% low-velocity anomaly centered beneath the volcanic edifice and peripheral high-velocity anomalies that likely correspond to cooled igneous intrusions. We suggest that the low-velocity anomaly reflects the high-porosity mixture of lava and ash deposits near the surface of the edifice, a highly fractured magmatic conduit and hydrothermal system beneath the volcano, and possibly a small contribution from silicate melt.

  9. Geology of the Ugashik-Mount Peulik Volcanic Center, Alaska

    Science.gov (United States)

    Miller, Thomas P.

    2004-01-01

    The Ugashik-Mount Peulik volcanic center, 550 km southwest of Anchorage on the Alaska Peninsula, consists of the late Quaternary 5-km-wide Ugashik caldera and the stratovolcano Mount Peulik built on the north flank of Ugashik. The center has been the site of explosive volcanism including a caldera-forming eruption and post-caldera dome-destructive activity. Mount Peulik has been formed entirely in Holocene time and erupted in 1814 and 1845. A large lava dome occupies the summit crater, which is breached to the west. A smaller dome is perched high on the southeast flank of the cone. Pyroclastic-flow deposits form aprons below both domes. One or more sector-collapse events occurred early in the formation of Mount Peulik volcano resulting in a large area of debris-avalanche deposits on the volcano's northwest flank. The Ugashik-Mount Peulik center is a calcalkaline suite of basalt, andesite, dacite, and rhyolite, ranging in SiO2 content from 51 to 72 percent. The Ugashik-Mount Peulik magmas appear to be co-genetic in a broad sense and their compositional variation has probably resulted from a combination of fractional crystallization and magma-mixing. The most likely scenario for a future eruption is that one or more of the summit domes on Mount Peulik are destroyed as new magma rises to the surface. Debris avalanches and pyroclastic flows may then move down the west and, less likely, east flanks of the volcano for distances of 10 km or more. A new lava dome or series of domes would be expected to form either during or within some few years after the explosive disruption of the previous dome. This cycle of dome disruption, pyroclastic flow generation, and new dome formation could be repeated several times in a single eruption. The volcano poses little direct threat to human population as the area is sparsely populated. The most serious hazard is the effect of airborne volcanic ash on aircraft since Mount Peulik sits astride heavily traveled air routes connecting the U

  10. Vasculitic peripheral neuropathy

    Directory of Open Access Journals (Sweden)

    Mona Amini

    2014-02-01

    Full Text Available Primary systemic vasculitis in pre-capillary arteries is associated with peripheral neuropathy. In some types of systematic vasculitis about 60 % of patients have peripheral nervous system (PNS involvement. In vasculitic peripheral neuropathies (VPN a necrotizing and inflammatory process leads to narrowing of vasa nervorum lumen and eventually the appearance of ischemic lesions in peripheral nerves. Some features might be suggestive of VPN, like: axonal nerve degeneration, wallerian-like degeneration, and diameter irregularity of nerve. Peripheral nervous system (PNS destruction during systemic vasculitides should be considered, due to its frequency and early occurrence in vasculitis progression. The first line treatment of non systematic VPNs is corticosteroid agents, but these drugs might worsen the VPNs or systemic vasculitis.

  11. Isogloss: language and legacy on Mount St. Helens

    Science.gov (United States)

    E. Dodd

    2012-01-01

    Nothing standing aboveground today was here thirty years ago. The ground itself wasn't here. Oh, there was ground, but much of it lay below the surface where my boot soles slip a little in the loose pebbles of pumice. Rolling on loose rock and big ideas, for a moment I lose my sense of balance, glancing first at the sky above, then at the nearby peak of Mount St...

  12. Adjustable bipod flexures for mounting mirrors in a space telescope.

    Science.gov (United States)

    Kihm, Hagyong; Yang, Ho-Soon; Moon, Il Kweon; Yeon, Jeong-Heum; Lee, Seung-Hoon; Lee, Yun-Woo

    2012-11-10

    A new mirror mounting technique applicable to the primary mirror in a space telescope is presented. This mounting technique replaces conventional bipod flexures with flexures having mechanical shims so that adjustments can be made to counter the effects of gravitational distortion of the mirror surface while being tested in the horizontal position. Astigmatic aberration due to the gravitational changes is effectively reduced by adjusting the shim thickness, and the relation between the astigmatism and the shim thickness is investigated. We tested the mirror interferometrically at the center of curvature using a null lens. Then we repeated the test after rotating the mirror about its optical axis by 180° in the horizontal setup, and searched for the minimum system error. With the proposed flexure mount, the gravitational stress at the adhesive coupling between the mirror and the mount is reduced by half that of a conventional bipod flexure for better mechanical safety under launch loads. Analytical results using finite element methods are compared with experimental results from the optical interferometer. Vibration tests verified the mechanical safety and optical stability, and qualified their use in space applications.

  13. 49 CFR 179.10 - Tank mounting.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Tank mounting. 179.10 Section 179.10 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY... Design Requirements § 179.10 Tank mounting. (a) The manner in which tanks are attached to the car...

  14. Low-Thermal-Resistance Baseplate Mounting

    Science.gov (United States)

    Perreault, W. T.

    1984-01-01

    Low-thermal-resistance mounting achieved by preloading baseplate to slight convexity with screws threaded through beam. As mounting bolts around edge of base-place tightened, baseplate and cold plate contact first in center, with region of intimate contact spreading outward as bolts tightened.

  15. Mount Athos: Between autonomy and statehood

    Directory of Open Access Journals (Sweden)

    Avramović Dragutin

    2013-01-01

    Full Text Available Legal status of the Mount Athos is characterized by many special features that make it internationally unique legal regime. The author analyzes peculiarities of Mount Athos territorial status, legal position of residents and visitors, as well as organization of Mount Athos authorities. The author concludes that the Mount Athos is characterized by a kind of para-sovereignty. Its autonomy involves not only the internal organization, autonomous governance and religious autonomy, but it also includes many elements of secular life of their visitors. Mount Athos has its own, separate legislative, administrative and judicial powers, while the Statute of the Mount Athos has greater legal force than all the other laws of the Greek state, because the state can not unilaterally change its provisions. Having in mind that the wide self-government is vested in church authorities and that the monks have very specific way of living, the author takes a position that the Mount Athos represent 'monastic state', but without statehood. The author also states that the Mount Athos will be faced with many challenges in the context of spreading of an assimilating, universal conception of human rights.

  16. Donating Peripheral Blood Stem Cells

    Science.gov (United States)

    ... Print this page My Cart Donating peripheral blood stem cells Peripheral blood stem cell (PBSC) donation is a nonsurgical procedure to collect ... Donating bone marrow Donor experiences videos Peripheral blood stem cell (PBSC) donation is one of two methods of ...

  17. Peripheral Neuropathy: Symptoms and Signs

    Science.gov (United States)

    ... Utah Research News Make a Difference Symptoms of Peripheral Neuropathy Print This Page Peripheral Neuropathy symptoms usually start ... more slowly over many years. The symptoms of peripheral neuropathy often include: A sensation of wearing an invisible “ ...

  18. Mounted Smartphones as Measurement and Control Platforms for Motor-Based Laboratory Test-Beds †

    Science.gov (United States)

    Frank, Jared A.; Brill, Anthony; Kapila, Vikram

    2016-01-01

    Laboratory education in science and engineering often entails the use of test-beds equipped with costly peripherals for sensing, acquisition, storage, processing, and control of physical behavior. However, costly peripherals are no longer necessary to obtain precise measurements and achieve stable feedback control of test-beds. With smartphones performing diverse sensing and processing tasks, this study examines the feasibility of mounting smartphones directly to test-beds to exploit their embedded hardware and software in the measurement and control of the test-beds. This approach is a first step towards replacing laboratory-grade peripherals with more compact and affordable smartphone-based platforms, whose interactive user interfaces can engender wider participation and engagement from learners. Demonstrative cases are presented in which the sensing, computation, control, and user interaction with three motor-based test-beds are handled by a mounted smartphone. Results of experiments and simulations are used to validate the feasibility of mounted smartphones as measurement and feedback control platforms for motor-based laboratory test-beds, report the measurement precision and closed-loop performance achieved with such platforms, and address challenges in the development of platforms to maintain system stability. PMID:27556464

  19. Mounted Smartphones as Measurement and Control Platforms for Motor-Based Laboratory Test-Beds

    Directory of Open Access Journals (Sweden)

    Jared A. Frank

    2016-08-01

    Full Text Available Laboratory education in science and engineering often entails the use of test-beds equipped with costly peripherals for sensing, acquisition, storage, processing, and control of physical behavior. However, costly peripherals are no longer necessary to obtain precise measurements and achieve stable feedback control of test-beds. With smartphones performing diverse sensing and processing tasks, this study examines the feasibility of mounting smartphones directly to test-beds to exploit their embedded hardware and software in the measurement and control of the test-beds. This approach is a first step towards replacing laboratory-grade peripherals with more compact and affordable smartphone-based platforms, whose interactive user interfaces can engender wider participation and engagement from learners. Demonstrative cases are presented in which the sensing, computation, control, and user interaction with three motor-based test-beds are handled by a mounted smartphone. Results of experiments and simulations are used to validate the feasibility of mounted smartphones as measurement and feedback control platforms for motor-based laboratory test-beds, report the measurement precision and closed-loop performance achieved with such platforms, and address challenges in the development of platforms to maintain system stability.

  20. Mounted Smartphones as Measurement and Control Platforms for Motor-Based Laboratory Test-Beds.

    Science.gov (United States)

    Frank, Jared A; Brill, Anthony; Kapila, Vikram

    2016-08-20

    Laboratory education in science and engineering often entails the use of test-beds equipped with costly peripherals for sensing, acquisition, storage, processing, and control of physical behavior. However, costly peripherals are no longer necessary to obtain precise measurements and achieve stable feedback control of test-beds. With smartphones performing diverse sensing and processing tasks, this study examines the feasibility of mounting smartphones directly to test-beds to exploit their embedded hardware and software in the measurement and control of the test-beds. This approach is a first step towards replacing laboratory-grade peripherals with more compact and affordable smartphone-based platforms, whose interactive user interfaces can engender wider participation and engagement from learners. Demonstrative cases are presented in which the sensing, computation, control, and user interaction with three motor-based test-beds are handled by a mounted smartphone. Results of experiments and simulations are used to validate the feasibility of mounted smartphones as measurement and feedback control platforms for motor-based laboratory test-beds, report the measurement precision and closed-loop performance achieved with such platforms, and address challenges in the development of platforms to maintain system stability.

  1. Drill cuttings mount formation study

    Science.gov (United States)

    Teh, Su Yean; Koh, Hock Lye

    2014-07-01

    Oil, Gas and Energy sector has been identified as an essential driving force in the Malaysian Economic Transformation Programs (ETP). Recently confirmed discovery of many offshore oil and gas deposits in Malaysian waters has ignited new confidence in this sector. However, this has also spurred intense interest on safeguarding the health and environment of coastal waters in Malaysia from adverse impact resulting from offshore oil and gas production operation. Offshore discharge of spent drilling mud and rock cuttings is the least expensive and simplest option to dispose of large volumes of drilling wastes. But this onsite offshore disposal may have adverse environmental impacts on the water column and the seabed. It may also pose occupational health hazards to the workers living in the offshore platforms. It is therefore important to model the transport and deposition of drilling mud and rock cuttings in the sea to enable proper assessment of their adverse impacts on the environment and the workers. Further, accumulation of drill particles on the seabed may impede proper operation of pipelines on the seabed. In this paper, we present an in-house application model TUNA-PT developed to cater to local oil and gas industry needs to simulate the dispersion and mount formation of drill cuttings by offshore oil and gas exploration and production platforms. Using available data on Malaysian coastal waters, simulation analyses project a pile formation on the seabed with a maximum height of about 1 m and pile radius of around 30 to 50 m. Simulated pile heights are not sensitive to the heights of release of the cuttings as the sensitivity has been mitigated by the depth of water.

  2. An improved loopless mounting method for cryocrystallography

    International Nuclear Information System (INIS)

    Jian-Xun, Qi; Fan, Jiang

    2010-01-01

    Based on a recent loopless mounting method, a simplified loopless and bufferless crystal mounting method is developed for macromolecular crystallography. This simplified crystal mounting system is composed of the following components: a home-made glass capillary, a brass seat for holding the glass capillary, a flow regulator, and a vacuum pump for evacuation. Compared with the currently prevalent loop mounting method, this simplified method has almost the same mounting procedure and thus is compatible with the current automated crystal mounting system. The advantages of this method include higher signal-to-noise ratio, more accurate measurement, more rapid flash cooling, less x-ray absorption and thus less radiation damage to the crystal. This method can be extended to the flash-freeing of a crystal without or with soaking it in a lower concentration of cryoprotectant, thus it may be the best option for data collection in the absence of suitable cryoprotectant. Therefore, it is suggested that this mounting method should be further improved and extensively applied to cryocrystallographic experiments. (general)

  3. An improved loopless mounting method for cryocrystallography

    Science.gov (United States)

    Qi, Jian-Xun; Jiang, Fan

    2010-01-01

    Based on a recent loopless mounting method, a simplified loopless and bufferless crystal mounting method is developed for macromolecular crystallography. This simplified crystal mounting system is composed of the following components: a home-made glass capillary, a brass seat for holding the glass capillary, a flow regulator, and a vacuum pump for evacuation. Compared with the currently prevalent loop mounting method, this simplified method has almost the same mounting procedure and thus is compatible with the current automated crystal mounting system. The advantages of this method include higher signal-to-noise ratio, more accurate measurement, more rapid flash cooling, less x-ray absorption and thus less radiation damage to the crystal. This method can be extended to the flash-freeing of a crystal without or with soaking it in a lower concentration of cryoprotectant, thus it may be the best option for data collection in the absence of suitable cryoprotectant. Therefore, it is suggested that this mounting method should be further improved and extensively applied to cryocrystallographic experiments.

  4. Peripheral Ulcerative Keratitis

    Science.gov (United States)

    ... oval in shape. Diagnosis A doctor's evaluation Sometimes culture The diagnosis of peripheral ulcerative keratitis is suspected when the doctor sees the affected cornea in a person who also has a severe and/or long- ...

  5. Tumors of peripheral nerves

    International Nuclear Information System (INIS)

    Ho, Michael; Lutz, Amelie M.

    2017-01-01

    Differentiation between malignant and benign tumors of peripheral nerves in the early stages is challenging; however, due to the unfavorable prognosis of malignant tumors early identification is required. To show the possibilities for detection, differential diagnosis and clinical management of peripheral nerve tumors by imaging appearance in magnetic resonance (MR) neurography. Review of current literature available in PubMed and MEDLINE, supplemented by the authors' own observations in clinical practice. Although not pathognomonic, several imaging features have been reported for a differentiation between distinct peripheral nerve tumors. The use of MR neurography enables detection and initial differential diagnosis in tumors of peripheral nerves. Furthermore, it plays an important role in clinical follow-up, targeted biopsy and surgical planning. (orig.) [de

  6. Development of a segmented grating mount system for FIREX-1

    International Nuclear Information System (INIS)

    Ezaki, Y; Tabata, M; Kihara, M; Horiuchi, Y; Endo, M; Jitsuno, T

    2008-01-01

    A mount system for segmented meter-sized gratings has been developed, which has a high precision grating support mechanism and drive mechanism to minimize both deformation of the optical surfaces and misalignments in setting a segmented grating for obtaining sufficient performance of the pulse compressor. From analytical calculations, deformation of the grating surface is less than 1/20 lambda RMS and the estimated drive resolution for piston and tilt drive of the segmented grating is 1/20 lambda, which are both compliant with the requirements for the rear-end subsystem of FIREX-1

  7. Promoting peripheral myelin repair

    OpenAIRE

    Zhou, Ye; Notterpek, Lucia

    2016-01-01

    Compared to the central nervous system (CNS), peripheral nerves have a remarkable ability to regenerate and remyelinate. This regenerative capacity to a large extent is dependent on and supported by Schwann cells, the myelin-forming glial cells of the peripheral nervous system (PNS). In a variety of paradigms, Schwann cells are critical in the removal of the degenerated tissue, which is followed by remyelination of newly-regenerated axons. This unique plasticity of Schwann cells has been the ...

  8. Flow distortion on boom mounted cup anemometers

    DEFF Research Database (Denmark)

    Lindelöw, Per Jonas Petter; Friis Pedersen, Troels; Gottschall, Julia

    In this report we investigate on wind direction dependent errors in the measurement of the horizontal wind speed by boom mounted cup anemometers. The boom mounting on the studied lattice tower is performed according to IEC standard design rules, yet, larger deviations than predicted by flow models...... are observed. The errors on the measurements are likely caused by an underestimation of the flow distortions around the tower. In this paper an experimental method for deriving a correction formula and an in-field calibration is suggested. The method is based on measurements with two cup anemometers mounted...

  9. Longitudinally mounted light emitting plasma in a dielectric resonator

    Energy Technology Data Exchange (ETDEWEB)

    Gilliard, Richard; DeVincentis, Marc; Hafidi, Abdeslam; O' Hare, Daniel; Hollingsworth, Gregg [LUXIM Corporation, 1171 Borregas Avenue, Sunnyvale, CA 94089 (United States)

    2011-06-08

    Methods for coupling power from a dielectric resonator to a light-emitting plasma have been previously described (Gilliard et al IEEE Trans. Plasma Sci. at press). Inevitably, regardless of the efficiency of power transfer, much of the emitted light is absorbed in the resonator itself which physically surrounds much if not all of the radiating material. An investigation into a method is presented here for efficiently coupling power to a longitudinally mounted plasma vessel which is mounted on the surface of the dielectric material of the resonator, thereby eliminating significant absorption of light within the resonator structure. The topology of the resonator and its physical properties as well as those of the metal halide plasma are presented. Results of basic models of the field configuration and plasma are shown as well as a configuration suitable as a practical light source.

  10. Biodiversity of the flora of Mount Papa

    International Nuclear Information System (INIS)

    Yin-Yin-Kyi

    1995-07-01

    Even though Mount Papa is in the dry zone area, it is almost evergreen, due to its elevation of 4981 feet above the sea level and its fertile soil conditions. A has a rich biodiversity with vegetation of many types

  11. May 1980 Mount Saint Helens, USA Images

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — An earthquake occurred at 15 32 UT, only seconds before the explosion that began the eruption of Mount St. Helens volcano. This eruption and blast blew off the top...

  12. Photoelectric panel with equatorial mounting of drive

    Science.gov (United States)

    Kukhta, M. S.; Krauinsh, P. Y.; Krauinsh, D. P.; Sokolov, A. P.; Mainy, S. B.

    2018-03-01

    The relevance of the work is determined by the need to create effective models for sunny energy. The article considers a photoelectric panel equipped with a system for tracking the sun. Efficiency of the system is provided by equatorial mounting, which compensates for the rotation of the Earth by rotating the sunny panel in the plane of the celestial equator. The specificity of climatic and geographical conditions of Tomsk is estimated. The dynamics of power variations of photoelectric panels with equatorial mounting during seasonal fluctuations in Tomsk is calculated. A mobile photovoltaic panel with equatorial mounting of the drive has been developed. The methods of design strategy for placing photovoltaic panels in the architectural environment of the city are presented. Key words: sunny energy, photovoltaics, equatorial mounting, mechatronic model, wave reducer, electric drive.

  13. Mount Protects Thin-Walled Glass or Ceramic Tubes from Large Thermal and Vibration Loads

    Science.gov (United States)

    Amato, Michael; Schmidt, Stephen; Marsh. James; Dahya, Kevin

    2011-01-01

    The design allows for the low-stress mounting of fragile objects, like thin walled glass, by using particular ways of compensating, isolating, or releasing the coefficient of thermal expansion (CTE) differences between the mounted object and the mount itself. This mount profile is lower than true full kinematic mounting. Also, this approach enables accurate positioning of the component for electrical and optical interfaces. It avoids the higher and unpredictable stress issues that often result from potting the object. The mount has been built and tested to space-flight specifications, and has been used for fiber-optic, optical, and electrical interfaces for a spaceflight mission. This mount design is often metal and is slightly larger than the object to be mounted. The objects are optical or optical/electrical, and optical and/or electrical interfaces are required from the top and bottom. This requires the mount to be open at both ends, and for the object s position to be controlled. Thin inside inserts at the top and bottom contact the housing at defined lips, or edges, and hold the fragile object in the mount. The inserts can be customized to mimic the outer surface of the object, which further reduces stress. The inserts have the opposite CTE of the housing material, partially compensating for the CTE difference that causes thermal stress. A spring washer is inserted at one end to compensate for more CTE difference and to hold the object against the location edge of the mount for any optical position requirements. The spring also ensures that any fiber-optic or optic interface, which often requires some pressure to ensure a good interface, does not overstress the fragile object. The insert thickness, material, and spring washer size can be traded against each other to optimize the mount and stresses for various thermal and vibration load ranges and other mounting requirements. The alternate design uses two separate, unique features to reduce stress and hold the

  14. Isolation Mounting for Charge-Coupled Devices

    Science.gov (United States)

    Goss, W. C.; Salomon, P. M.

    1985-01-01

    CCD's suspended by wires under tension. Remote thermoelectric cooling of charge coupled device allows vibration isolating mounting of CCD assembly alone, without having to suspend entire mass and bulk of thermoelectric module. Mounting hardware simple and light. Developed for charge-coupled devices (CCD's) in infrared telescope support adaptable to sensors in variety of environments, e.g., sensors in nuclear reactors, engine exhausts and plasma chambers.

  15. "Split Cast Mounting: Review and New Technique".

    Science.gov (United States)

    Gundawar, S M; Pande, Neelam A; Jaiswal, Priti; Radke, U M

    2014-12-01

    For the fabrication of a prosthesis, the Prosthodontist meticulously performs all the steps. The laboratory technician then make every effort/strives to perform the remaining lab procedures. However when the processed dentures are remounted on the articulator, some changes are seen. These changes may be divided into two categories: Pre-insertion and post-insertion changes, which deal with the physical properties of the materials involved (Parker, J Prosthet Dent 31:335-342, 1974). Split cast mounting is the method of mounting casts on the articulator. It is essentially a maxillary cast constructed in two parts with a horizontal division. The procedure allows for the verification of the accuracy of the initial mounting and the ease of removal and replacement of the cast. This provides a precise means of correcting the changes in occlusion occurring as a result of the processing technique (Nogueira et al., J Prosthet Dent 91:386-388, 2004). Instability of the split mounting has always been a problem to the Prosthodontist thereby limiting its use. There are various materials mentioned in the literature. The new technique by using Dowel pins and twill thread is very easy, cheaper and simple way to stabilize the split mounting. It is useful and easy in day to day laboratory procedures. The article presents different methods of split cast mounting and the new procedure using easily available materials in prosthetic laboratory.

  16. Analysis of adjusting effects of mounting force on frequency conversion of mounted nonlinear optics.

    Science.gov (United States)

    Su, Ruifeng; Liu, Haitao; Liang, Yingchun; Lu, Lihua

    2014-01-10

    Motivated by the need to increase the second harmonic generation (SHG) efficiency of nonlinear optics with large apertures, a novel mounting configuration with active adjusting function on the SHG efficiency is proposed and mechanically and optically studied. The adjusting effects of the mounting force on the distortion and stress are analyzed by the finite element methods (FEM), as well as the contribution of the distortion and stress to the change in phase mismatch, and the SHG efficiency are theoretically stated. Further on, the SHG efficiency is calculated as a function of the mounting force. The changing trends of the distortion, stress, and the SHG efficiency with the varying mounting force are obtained, and the optimal ones are figured out. Moreover, the mechanism of the occurrence of the optimal values is studied and the adjusting strategy is put forward. Numerical results show the robust adjustment of the mounting force, as well as the effectiveness of the mounting configuration, in increasing the SHG efficiency.

  17. Technical preparation of the Yuzhteploehnergomontazh trust for technological equipment mounting

    International Nuclear Information System (INIS)

    Zayats, A.I.

    1982-01-01

    Measures of technical preparation for equipment mounting at the Zaporozhe NPP developed with the Yuzhteploehnergomontazh trust experts are considered. These measures envisage the construction of mounting base of heat facilities, calculation of labour contents and determination of necessary quantity of mounters, development of optimal flowsheet of mounting control, improvement of mounting qualification and creation of stable collective body, improvement of technical level of mounting and welding works, organizational-technical measures on mounting logistics. Factors affecting negatively technical preparation quality of equipment mounting at the Zaporozhe NPP are discussed. The flowsheet of mounting control is presented

  18. Perspective with Landsat Overlay, Mount Kilimanjaro, Tanzania

    Science.gov (United States)

    2002-01-01

    Mount Kilimanjaro (Kilima Njaro or 'shining mountain' in Swahili), the highest point in Africa, reaches 5,895 meters (19,340 feet) above sea level, tall enough to maintain a permanent snow cap despite being just 330 kilometers (210 miles) south of the equator. It is the tallest free-standing mountain on the Earth's land surface world, rising about 4,600 meters (15,000 feet) above the surrounding plain. Kilimanjaro is a triple volcano (has three peaks) that last erupted perhaps more than 100,000 years ago but still exudes volcanic gases. It is accompanied by about 20 other nearby volcanoes, some of which are seen to the west (left) in this view, prominently including Mount Meru, which last erupted only about a century ago. The volcanic mountain slopes are commonly fertile and support thick forests, while the much drier grasslands of the plains are home to elephants, lions, and other savanna wildlife.This 3-D perspective view was generated using topographic data from the Shuttle Radar Topography Mission (SRTM), a Landsat 7 satellite image, and a false sky. Topographic expression is vertically exaggerated two times.Landsat has been providing visible and infrared views of the Earth since 1972. SRTM elevation data matches the 30-meter (98-foot) resolution of most Landsat images and will substantially help in analyzing the large and growing Landsat image archive, managed by the U.S. Geological Survey (USGS).Elevation data used in this image was acquired by the Shuttle Radar Topography Mission (SRTM) aboard the Space Shuttle Endeavour, launched on Feb. 11, 2000. SRTM used the same radar instrument that comprised the Spaceborne Imaging Radar-C/X-Band Synthetic Aperture Radar (SIR-C/X-SAR) that flew twice on the Space Shuttle Endeavour in 1994. SRTM was designed to collect 3-D measurements of the Earth's surface. To collect the 3-D data, engineers added a 60-meter (approximately 200-foot) mast, installed additional C-band and X-band antennas, and improved tracking and

  19. Peripheral ossifying fibroma of oral cavity: histopathologic differential diagnoses.

    Science.gov (United States)

    Shamim, Thorakkal

    2012-01-01

    Peripheral ossifying fibroma is a benign neoplasm that usuallydevelops from gingiva, presenting as an exophytic smooth surfaced pink or red nodular mass that is sessile or is less frequently seen on a pedicle. From the Indian perspective, it is usually noticed in 5th-6th decades of life with female predilection. Microscopically, the tumour shows stratified squamous epithelium and highly cellular fibrous stroma, sparse endothelial proliferation with fibroblasts and dystrophic calcifications. It has to be differentiated histopathologically from pyogenic granuloma, fibroma, peripheral giant cell granuloma, peripheral odontogenic fibroma and fibrous hyperplasia. A case of peripheral ossifying fibroma of maxillary gingiva in a 55-year-old Indian woman is reported.

  20. Peripheral epithelial odontogenic tumor

    International Nuclear Information System (INIS)

    Carzoglio, J.; Tancredi, N.; Capurro, S.; Ravecca, T.; Scarrone, P.

    2006-01-01

    A new case of peripheral epithelial odontogenic tumor (Pindborg tumor) is reported. It is localized in the superior right gingival region, a less frequent site, and has the histopathological features previously reported. Immunochemical studies were performed, revealing a differential positive stain to cytokeratins in tumor cells deeply seated in the tumor mass, probably related to tumoral cell heterogeneity.Interestingly, in this particular case S-100 protein positive reactivity was also detected in arborescent cells intermingled with tumoral cells, resembling Langerhans cells. Even though referred in the literature in central Pindborg tumors, no references were found about their presence in peripheral tumors, like the one that is presented here

  1. Peripheral Artery Disease

    Science.gov (United States)

    ... pressure High blood cholesterol Coronary heart disease Stroke Metabolic syndrome Screening and Prevention Taking action to control your risk factors can help prevent or delay peripheral artery disease (P.A.D.) and its complications. Know your family history of health problems related to P.A. ...

  2. Promoting peripheral myelin repair.

    Science.gov (United States)

    Zhou, Ye; Notterpek, Lucia

    2016-09-01

    Compared to the central nervous system (CNS), peripheral nerves have a remarkable ability to regenerate and remyelinate. This regenerative capacity to a large extent is dependent on and supported by Schwann cells, the myelin-forming glial cells of the peripheral nervous system (PNS). In a variety of paradigms, Schwann cells are critical in the removal of the degenerated tissue, which is followed by remyelination of newly-regenerated axons. This unique plasticity of Schwann cells has been the target of myelin repair strategies in acute injuries and chronic diseases, such as hereditary demyelinating neuropathies. In one approach, the endogenous regenerative capacity of Schwann cells is enhanced through interventions such as exercise, electrical stimulation or pharmacological means. Alternatively, Schwann cells derived from healthy nerves, or engineered from different tissue sources have been transplanted into the PNS to support remyelination. These transplant approaches can then be further enhanced by exercise and/or electrical stimulation, as well as by the inclusion of biomaterial engineered to support glial cell viability and neurite extension. Advances in our basic understanding of peripheral nerve biology, as well as biomaterial engineering, will further improve the functional repair of myelinated peripheral nerves. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. 76 FR 76689 - Cibola National Forest, Mount Taylor Ranger District, NM, Mount Taylor Combined Exploratory Drilling

    Science.gov (United States)

    2011-12-08

    ... National Forest, Mount Taylor Ranger District, NM, Mount Taylor Combined Exploratory Drilling AGENCY... proposed action is to approve two Plans of Operations for exploratory uranium drilling on the Cibola... San Mateo. In total, there are up to 279 drill holes that would be drilled over a period not to exceed...

  4. User's guide to designing and mounting lenses and mirrors

    International Nuclear Information System (INIS)

    Kowalskie, B.J.

    1978-01-01

    The guidebook is a practitioner-oriented supplement to standard texts in optics and mechanical engineering. It reflects practical experience with the oftentimes troublesome aspects of effectively integrating optical components with mechanical hardware. Accordingly, its focus is on the techniques, assumptions, and levels of design sophistication needed for a wide variety of sizes and optical surface quality levels. It is intended to be a primer for engineers, designers, and draftsmen already familiar with some of the problems encountered in mounting optical components and who are responsible for developing components for high-energy laser systems

  5. Ball mounting fixture for a roundness gage

    Science.gov (United States)

    Gauler, Allen L.; Pasieka, Donald F.

    1983-01-01

    A ball mounting fixture for a roundness gage is disclosed. The fixture includes a pair of chuck assemblies oriented substantially transversely with respect to one another and mounted on a common base. Each chuck assembly preferably includes a rotary stage and a wobble plate affixed thereto. A ball chuck affixed to each wobble plate is operable to selectively support a ball to be measured for roundness, with the wobble plate permitting the ball chuck to be tilted to center the ball on the axis of rotation of the rotary stage. In a preferred embodiment, each chuck assembly includes a vacuum chuck operable to selectively support the ball to be measured for roundness. The mounting fixture enables a series of roundness measurements to be taken with a conventional rotating gagehead roundness instrument, which measurements can be utilized to determine the sphericity of the ball.

  6. Transdermal optogenetic peripheral nerve stimulation

    Science.gov (United States)

    Maimon, Benjamin E.; Zorzos, Anthony N.; Bendell, Rhys; Harding, Alexander; Fahmi, Mina; Srinivasan, Shriya; Calvaresi, Peter; Herr, Hugh M.

    2017-06-01

    Objective: A fundamental limitation in both the scientific utility and clinical translation of peripheral nerve optogenetic technologies is the optical inaccessibility of the target nerve due to the significant scattering and absorption of light in biological tissues. To date, illuminating deep nerve targets has required implantable optical sources, including fiber-optic and LED-based systems, both of which have significant drawbacks. Approach: Here we report an alternative approach involving transdermal illumination. Utilizing an intramuscular injection of ultra-high concentration AAV6-hSyn-ChR2-EYFP in rats. Main results: We demonstrate transdermal stimulation of motor nerves at 4.4 mm and 1.9 mm depth with an incident laser power of 160 mW and 10 mW, respectively. Furthermore, we employ this technique to accurately control ankle position by modulating laser power or position on the skin surface. Significance: These results have the potential to enable future scientific optogenetic studies of pathologies implicated in the peripheral nervous system for awake, freely-moving animals, as well as a basis for future clinical studies.

  7. Direct mounted photovoltaic device with improved adhesion and method thereof

    Science.gov (United States)

    Boven, Michelle L; Keenihan, James R; Lickly, Stan; Brown, Jr., Claude; Cleereman, Robert J; Plum, Timothy C

    2014-12-23

    The present invention is premised upon a photovoltaic device suitable for directly mounting on a structure. The device includes an active portion including a photovoltaic cell assembly having a top surface portion that allows transmission of light energy to a photoactive portion of the photovoltaic device for conversion into electrical energy and a bottom surface having a bottom bonding zone; and an inactive portion immediately adjacent to and connected to the active portion, the inactive portion having a region for receiving a fastener to connect the device to the structure and having on a top surface, a top bonding zone; wherein one of the top and bottom bonding zones comprises a first bonding element and the other comprises a second bonding element, the second bonding element designed to interact with the first bonding element on a vertically overlapped adjacent photovoltaic device to bond the device to such adjacent device or to the structure.

  8. 14 CFR 33.23 - Engine mounting attachments and structure.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Engine mounting attachments and structure... mounting attachments and structure. (a) The maximum allowable limit and ultimate loads for engine mounting attachments and related engine structure must be specified. (b) The engine mounting attachments and related...

  9. Light emitting device having peripheral emissive region

    Science.gov (United States)

    Forrest, Stephen R

    2013-05-28

    Light emitting devices are provided that include one or more OLEDs disposed only on a peripheral region of the substrate. An OLED may be disposed only on a peripheral region of a substantially transparent substrate and configured to emit light into the substrate. Another surface of the substrate may be roughened or include other features to outcouple light from the substrate. The edges of the substrate may be beveled and/or reflective. The area of the OLED(s) may be relatively small compared to the substrate surface area through which light is emitted from the device. One or more OLEDs also or alternatively may be disposed on an edge of the substrate about perpendicular to the surface of the substrate through which light is emitted, such that they emit light into the substrate. A mode expanding region may be included between each such OLED and the substrate.

  10. Robotic mounting of ATLAS barrel SCT modules

    International Nuclear Information System (INIS)

    Nickerson, R.B.; Viehhauser, G.; Wastie, R.; Terada, S.; Unno, Y.; Kohriki, T.; Ikegami, Y.; Hara, K.; Kobayashi, H.; Barbier, G.; Clark, A.G.; Perrin, E.; Carter, A.A.; Mistry, J.; Morris, J.

    2006-01-01

    The 2112 silicon detector modules of the barrel part of the ATLAS SemiConductor Tracker (SCT) have been mounted on their carbon fibre support structure. Module insertion, placement and fixing were performed by robotic assembly tooling. We report on our experience with this assembly method. Part of the mounting sequence involves a partial survey of elements of the support structure which is needed to align the modules properly during insertion. An analysis of these data is used to estimate the positional accuracy of the robots

  11. Shaded Relief with Height as Color, Mount Meru, Tanzania

    Science.gov (United States)

    2002-01-01

    Mount Meru is an active volcano located just 70 kilometers (44 miles) west of Mount Kilimanjaro. It reaches 4,566 meters (14,978 feet) in height but has lost much of its bulk due to an eastward volcanic blast sometime in its distant past, perhaps similar to the eruption of Mount Saint Helens in Washington State in 1980. Mount Meru most recently had a minor eruption about a century ago. The several small cones and craters seen in the vicinity probably reflect numerous episodes of volcanic activity. Mount Meru is the topographic centerpiece of Arusha National Park. Its fertile slopes rise above the surrounding savanna and support a forest that hosts diverse wildlife, including nearly 400 species of birds, and also monkeys and leopards.Two visualization methods were combined to produce this image: shading and color coding of topographic height. The shade image was derived by computing topographic slope in the north-south direction. Northern slopes appear bright and southern slopes appear dark, as would be the case at noon at this latitude in June. Color coding is directly related to topographic height, with green at the lower elevations, rising through yellow, red, and magenta, to blue and white at the highest elevations.Elevation data used in this image was acquired by the Shuttle Radar Topography Mission (SRTM) aboard the Space Shuttle Endeavour, launched on Feb. 11, 2000. SRTM used the same radar instrument that comprised the Spaceborne Imaging Radar-C/X-Band Synthetic Aperture Radar (SIR-C/X-SAR) that flew twice on the Space Shuttle Endeavour in 1994. SRTM was designed to collect 3-D measurements of the Earth's surface. To collect the 3-D data, engineers added a 60-meter (approximately 200-foot) mast, installed additional C-band and X-band antennas, and improved tracking and navigation devices. The mission is a cooperative project between NASA, the National Imagery and Mapping Agency (NIMA) of the U.S. Department of Defense and the German and Italian space

  12. Resin bleed improvement on surface mount semiconductor device

    Science.gov (United States)

    Rajoo, Indra Kumar; Tahir, Suraya Mohd; Aziz, Faieza Abdul; Shamsul Anuar, Mohd

    2018-04-01

    Resin bleed is a transparent layer of epoxy compound which occurs during molding process but is difficult to be detected after the molding process. Resin bleed on the lead on the unit from the focused package, SOD123, can cause solderability failure at end customer. This failed unit from the customer will be considered as a customer complaint. Generally, the semiconductor company has to perform visual inspection after the plating process to detect resin bleed. Mold chase with excess hole, split cavity & stepped design ejector pin hole have been found to be the major root cause of resin bleed in this company. The modifications of the mold chase, changing of split cavity to solid cavity and re-design of the ejector pin proposed were derived after a detailed study & analysis conducted to arrive at these solutions. The solutions proposed have yield good results during the pilot run with zero (0) occurrence of resin bleed for 3 consecutive months.

  13. Creating Gaze Annotations in Head Mounted Displays

    DEFF Research Database (Denmark)

    Mardanbeigi, Diako; Qvarfordt, Pernilla

    2015-01-01

    To facilitate distributed communication in mobile settings, we developed GazeNote for creating and sharing gaze annotations in head mounted displays (HMDs). With gaze annotations it possible to point out objects of interest within an image and add a verbal description. To create an annota- tion...

  14. Bearing-Mounting Concept Accommodates Thermal Expansion

    Science.gov (United States)

    Nespodzany, Robert; Davis, Toren S.

    1995-01-01

    Pins or splines allow radial expansion without slippage. Design concept for mounting rotary bearing accommodates differential thermal expansion between bearing and any structure(s) to which bearing connected. Prevents buildup of thermal stresses by allowing thermal expansion to occur freely but accommodating expansion in such way not to introduce looseness. Pin-in-slot configuration also maintains concentricity.

  15. Motion planning for gantry mounted manipulators

    DEFF Research Database (Denmark)

    Olsen, Anders Lau; Petersen, Henrik Gordon

    2007-01-01

    We present a roadmap based planner for finding robot motions for gantry mounted manipulators for a line welding application at Odense Steel Shipyard (OSS). The robot motions are planned subject to constraints on when the gantry may be moved. We show that random sampling of gantry configurations...

  16. Mounting LHCb hadron calorimeter scintillating tiles

    CERN Multimedia

    Maximilien Brice

    2004-01-01

    Scintillating tiles are carefully mounted in the hadronic calorimeter for the LHCb detector. These calorimeters measure the energy of particles that interact via the strong force, called hadrons. The detectors are made in a sandwich-like structure where these scintillator tiles are placed between metal sheets.

  17. Solidly Mounted Resonator with Optimized Acoustic Reflector

    NARCIS (Netherlands)

    Jose, Sumy; Jansman, Andreas; Hueting, Raymond Josephus Engelbart

    2009-01-01

    The quality factor (Q) of the Solidly Mounted Resonator is limited by acoustic losses caused by waves leaking through the mirror stack. Traditionally employed acoustic mirror reflects only longitudinal waves and not shear waves. Starting with the stop-band theory and the principle of spacer layers

  18. Dynamic characteristics of mirrors' kinematic mount

    International Nuclear Information System (INIS)

    Wu Wenkai; Du Qiang; Li Jingze; Chen Gang; Chen Xiaojuan; Xu Yuanli

    2002-01-01

    Applying exact constrain design principles, kinematic mount for precision positioning large aperture mirrors is designed; theoretical method is introduced to analyze its dynamic characteristics and the result of the experiment for mirrors, stability; accordingly, the methods to improve design are put forward

  19. Making sense of Mount St. Helens

    Science.gov (United States)

    Steve Nash

    2010-01-01

    The eruption of Mount St. Helens in 1980 resulted in "a grand experiment that you could never have gotten anybody to fund," says Forest Service ecologist Charles Crisafulli. "Everything's new. It's a new landform." Unlike most misbehaving volcanoes, this one provided an accessible laboratory right along the Interstate-5 corridor, with the...

  20. June 1992 Mount Spurr, USA Images

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Following 39 years of inactivity, Crater Peak vent on the south flank of Mount Spurr volcano burst into eruption at 7:04 a.m. Alaska daylight time (ADT) on June 27,...

  1. 49 CFR 587.19 - Mounting.

    Science.gov (United States)

    2010-10-01

    ... Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) DEFORMABLE BARRIERS Offset Deformable Barrier § 587.19 Mounting. (a) The deformable face is rigidly attached to the edge of the fixed rigid barrier or to some rigid...

  2. Peripheral orbit model

    CERN Document Server

    Hara, Yasuo

    1975-01-01

    Peripheral orbit model, in which an incoming hadron is assumed to revolve in a peripheral orbit around a target hadron, is discussed. The non-diffractive parts of two-body reaction amplitudes of hadrons are expressed in terms of the radius, width an absorptivity of the orbit. The radius of the orbit is about 1 fm and the width of the orbit is determined by the range of the interaction between the hadrons. The model reproduces all available experimental data on differential cross-sections and polarizations of $K^{-}p\\to K^{-}p$ and $\\bar K^{\\circ}n$ reactions for all angles successfully. This contribution is not included in the proceedings since it will appear in Progress of Theoretical Physics Vol. 51 (1974) No 2. Any person interested in the subject may apply for reprints to the author.

  3. Low-stress mounting configuration design for large aperture laser transport mirror

    Science.gov (United States)

    Zhang, Zheng; Quan, Xusong; Yao, Chao; Wang, Hui

    2016-10-01

    TM1-6S1 large aperture laser transport mirror is a crucial optical unit of high power solid-state laser in the Inertial Confinement Fusion (ICF) facility. This article focuses on the low-stress and precise mounting method of large-aperture mirror. Based on the engineering practice of SG-III, the state-of-the-art and key problems of current mounting configuration are clarified firstly. Subsequently, a brand new low-stress mounting configuration with flexure supports is proposed. Opto-mechanical model of the mirror under mounting force is built up with elastic mechanics theory. Further, numerical methods and field tests are employed to verify the favorable load uniform capacity and load adjust capacity of flexure supports. With FEM, the relation between the mounting force from new configuration and the mirror surface distortion (wavefront error) is clarified. The novel mounting method of large aperture optics could be not only used on this laser transport mirror, but also on the other transmission optics and large crystals in ICF facilities.

  4. Optimised mounting conditions for poly (ether sulfone) in radiation detection.

    Science.gov (United States)

    Nakamura, Hidehito; Shirakawa, Yoshiyuki; Sato, Nobuhiro; Yamada, Tatsuya; Kitamura, Hisashi; Takahashi, Sentaro

    2014-09-01

    Poly (ether sulfone) (PES) is a candidate for use as a scintillation material in radiation detection. Its characteristics, such as its emission spectrum and its effective refractive index (based on the emission spectrum), directly affect the propagation of light generated to external photodetectors. It is also important to examine the presence of background radiation sources in manufactured PES. Here, we optimise the optical coupling and surface treatment of the PES, and characterise its background. Optical grease was used to enhance the optical coupling between the PES and the photodetector; absorption by the grease of short-wavelength light emitted from PES was negligible. Diffuse reflection induced by surface roughening increased the light yield for PES, despite the high effective refractive index. Background radiation derived from the PES sample and its impurities was negligible above the ambient, natural level. Overall, these results serve to optimise the mounting conditions for PES in radiation detection. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Shoulder-Mounted Robot for MRI-guided arthrography: Accuracy and mounting study.

    Science.gov (United States)

    Monfaredi, R; Wilson, E; Sze, R; Sharma, K; Azizi, B; Iordachita, I; Cleary, K

    2015-08-01

    A new version of our compact and lightweight patient-mounted MRI-compatible 4 degree-of-freedom (DOF) robot for MRI-guided arthrography procedures is introduced. This robot could convert the traditional two-stage arthrography procedure (fluoroscopy-guided needle insertion followed by a diagnostic MRI scan) to a one-stage procedure, all in the MRI suite. The results of a recent accuracy study are reported. A new mounting technique is proposed and the mounting stability is investigated using optical and electromagnetic tracking on an anthropomorphic phantom. Five volunteer subjects including 2 radiologists were asked to conduct needle insertion in 4 different random positions and orientations within the robot's workspace and the displacement of the base of the robot was investigated during robot motion and needle insertion. Experimental results show that the proposed mounting method is stable and promising for clinical application.

  6. Systems and methods for mirror mounting with minimized distortion

    Science.gov (United States)

    Antonille, Scott R. (Inventor); Wallace, Thomas E. (Inventor); Content, David A. (Inventor); Wake, Shane W. (Inventor)

    2012-01-01

    A method for mounting a mirror for use in a telescope includes attaching the mirror to a plurality of adjustable mounts; determining a distortion in the mirror caused by the plurality adjustable mounts, and, if the distortion is determined to be above a predetermined level: adjusting one or more of the adjustable mounts; and determining the distortion in the mirror caused by the adjustable mounts; and in the event the determined distortion is determined to be at or below the predetermined level, rigidizing the adjustable mounts.

  7. Increased earthquake safety through optimised mounting concept

    International Nuclear Information System (INIS)

    Kollmann, Dieter; Senechal, Holger

    2013-01-01

    Since Fukushima, there has been intensive work on earthquake safety in all nuclear power plants. A large part of these efforts aim at the earthquake safety of safety-relevant pipeline systems. The problem with earthquake safety here is not the pipeline system itself but rather its mountings and connections to components. This is precisely the topic that the KAE dealt with in years of research and development work. It has developed an algorithm that determines the optimal mounting concept with a few iteration steps depending on arbitrary combinations of loading conditions whilst maintaining compliance with relevant regulations for any pipeline systems. With this tool at hand, we are now in a position to plan and realise remedial measures accurately with minimum time and hardware expenditure, and so distinctly improve the earthquake safety of safety-relevant systems. (orig.)

  8. Micro-inverter solar panel mounting

    Science.gov (United States)

    Morris, John; Gilchrist, Phillip Charles

    2016-02-02

    Processes, systems, devices, and articles of manufacture are provided. Each may include adapting micro-inverters initially configured for frame-mounting to mounting on a frameless solar panel. This securement may include using an adaptive clamp or several adaptive clamps secured to a micro-inverter or its components, and using compressive forces applied directly to the solar panel to secure the adaptive clamp and the components to the solar panel. The clamps can also include compressive spacers and safeties for managing the compressive forces exerted on the solar panels. Friction zones may also be used for managing slipping between the clamp and the solar panel during or after installation. Adjustments to the clamps may be carried out through various means and by changing the physical size of the clamps themselves.

  9. Daspsone Induced Peripheral Neuropathy

    Directory of Open Access Journals (Sweden)

    P A Sarojini

    1988-01-01

    Full Text Available A 24 year old lady being treated with 300 mg of dapsone daily for dermatitits herpetiformis, developed weakness and wasting of muscles of feet with claw hand deformity and t drop, 2 months tater. Neurological examination and nerve conduction studies conformed the presence of a peripheral motor neuropathy. Dapsone was discontinued and the patient was treated with cotrimatoxazole, gluten-free diet and supportive therapy. This satisfactorily controlled the dermatological lesion without adversely affecting the resolution of her neuropthy. Symptomatic improvement reported by the patient was confirmed by EMG and nerve conduction studies.

  10. Mapping the Spread of Mounted Warfare

    Directory of Open Access Journals (Sweden)

    Peter Turchin

    2016-12-01

    Full Text Available Military technology is one of the most important factors affecting the evolution of complex societies. In particular, mounted warfare, the use of horse-riders in military operations, revolutionized war as it spread to different parts of Eurasia and Africa during the Ancient and Medieval eras, and to the Americas during the Early Modern period. Here we use a variety of sources to map this spread.

  11. New mounting improves solar-cell efficiency

    Science.gov (United States)

    Shepard, N. F., Jr.

    1980-01-01

    Method boosts output by about 20 percent by trapping and redirecting solar radiation without increasing module depth. Mounted solar-cell array is covered with internally reflecting plate. Plate is attached to each cell by transparent adhesive, and space between cells is covered with layer of diffusely reflecting material. Solar energy falling on space between cells is diffused and reflected internally by plate until it is reflected onto solar cell.

  12. Customer Satisfaction Level in Mount Sherpa Restaurant

    OpenAIRE

    Shrestha, Sameer

    2015-01-01

    Customer satisfaction is the key to every successful business in the sense of profit motive, as well as in the long run. It is the desire of every business to be able to understand their customers’ need. Many businesses, especially related with the service industry, carry out different surveys and conduct research in order to know what their customers really want. This research was carried out to measure the customer satisfaction level in Mount Sherpa restaurant. The results and findings ...

  13. Conceptual design for PSP mounting bracket

    Energy Technology Data Exchange (ETDEWEB)

    Ransom, G.; Stein, R. [Martin Marietta Energy Systems, Inc., Piketon, OH (United States)

    1991-12-31

    Protective structural packages (PSP`s or overpacks) used to ship 2 1/2-ton UF{sub 6} product cylinders are bolted to truck trailers. All bolts penetrate two longitudinal rows of wooden planks. Removal and replacement is required at various intervals for maintenance and routine testing. A conceptual design is presented for mounting brackets which would securely attach PSP`s to trailer frames, reduce removal and replacement time, and minimize risk of personnel injury.

  14. Peripheral Protein Unfolding Drives Membrane Bending.

    Science.gov (United States)

    Siaw, Hew Ming Helen; Raghunath, Gokul; Dyer, R Brian

    2018-06-20

    Dynamic modulation of lipid membrane curvature can be achieved by a number of peripheral protein binding mechanisms such as hy-drophobic insertion of amphipathic helices and membrane scaffolding. Recently, an alternative mechanism was proposed in which crowding of peripherally bound proteins induces membrane curvature through steric pressure generated by lateral collisions. This effect was enhanced using intrinsically disordered proteins that possess high hydrodynamic radii, prompting us to explore whether membrane bending can be triggered by the folding-unfolding transition of surface-bound proteins. We utilized histidine-tagged human serum albumin bound to Ni-NTA-DGS containing liposomes as our model system to test this hypothesis. We found that reduction of the disulfide bonds in the protein resulted in unfolding of HSA, which subsequently led to membrane tubule formation. The frequency of tubule formation was found to be significantly higher when the proteins were unfolded while being localized to a phase-separated domain as opposed to randomly distributed in fluid phase liposomes, indicating that the steric pressure generated from protein unfolding is directly responsible for membrane deformation. Our results are critical for the design of peripheral membrane protein-immobilization strategies and open new avenues for exploring mechanisms of membrane bending driven by conformational changes of peripheral membrane proteins.

  15. Eddy current testing system for bottom mounted instrumentation welds - 15206

    International Nuclear Information System (INIS)

    Kobayashi, N.; Ueno, S.; Suganuma, N.; Oodake, T.; Maehara, T.; Kasuya, T.; Ichikawa, H.

    2015-01-01

    We have demonstrated the scanning of eddy current testing (ECT) probe on the welds area including the nozzle, the J-welds and the buildup welds of the Bottom Mounted Instrumentation (BMI) mock-up using the developed ECT system and procedure. It is difficult to scan the probe on the BMI welds area because the area has a complex curved surface shape and narrow spaces. We made the space coordinates and the normal vectors on the scanning points as the scanning trajectory of probe on the welds area based on the measured results of welds surface shape on the mock-up. The multi-axis robot was used to scan the probe on the welds surface. Each motion axis position of the robot corresponding to each scanning point was calculated by the inverse kinematic algorithm. The BMI mock-up test was performed using the cross coil probe in the differential mode. The artificial stress corrosion cracking and the electrical discharge machining slits given on the mock-up surface were detected. The results show that the ECT can detect a defect of approximately 2.3 mm in length, 0.5 mm in depth and 0.2 mm in width for the BMI welds. From the output voltage of single coil, we estimated that the average and the maximum probe tilt angles on the mock-up surface under scanning were 2.6 degrees and 8.5 degrees, respectively

  16. Eddy current testing system for bottom mounted instrumentation welds

    Directory of Open Access Journals (Sweden)

    Kobayashi Noriyasu

    2015-01-01

    Full Text Available The capability of eddy current testing (ECT for the bottom mounted instrumentation (BMI weld area of reactor vessel in a pressurized water reactor was demonstrated by the developed ECT system and procedure. It is difficult to position and move the probe on the BMI weld area because the area has complexly curved surfaces. The space coordinates and the normal vectors at the scanning points were calculated as the scanning trajectory of probe based on the measured results of surface shape on the BMI mock-up. The multi-axis robot was used to move the probe on the mock-up. Each motion-axis position of the robot corresponding to each scanning point was calculated by the inverse kinematic algorithm. In the mock-up test, the probe was properly contacted with most of the weld surfaces. The artificial stress corrosion cracking of approximately 6 mm in length and the electrical-discharge machining slit of 0.5 mm in length, 1 mm in depth and 0.2 mm in width given on the weld surface were detected. From the probe output voltage, it was estimated that the average probe tilt angle on the surface under scanning was 2.6°.

  17. Vibration reduction and power generation with piezoceramic sheets mounted to a flexible shaft

    NARCIS (Netherlands)

    Sloetjes, P.J.; de Boer, Andries

    2008-01-01

    A flexible shaft with surface-mounted piezoceramic sheets and strain sensors is considered which suffers from resonance and self-excited vibration. Frequency domain models, time domain simulations, and control experiments are used to analyze active modal damping and active modal balancing methods.

  18. Microwave Temperature Profiler Mounted in a Standard Airborne Research Canister

    Science.gov (United States)

    Mahoney, Michael J.; Denning, Richard F.; Fox, Jack

    2009-01-01

    Many atmospheric research aircraft use a standard canister design to mount instruments, as this significantly facilitates their electrical and mechanical integration and thereby reduces cost. Based on more than 30 years of airborne science experience with the Microwave Temperature Profiler (MTP), the MTP has been repackaged with state-of-the-art electronics and other design improvements to fly in one of these standard canisters. All of the controlling electronics are integrated on a single 4 5-in. (.10 13- cm) multi-layer PCB (printed circuit board) with surface-mount hardware. Improved circuit design, including a self-calibrating RTD (resistive temperature detector) multiplexer, was implemented in order to reduce the size and mass of the electronics while providing increased capability. A new microcontroller-based temperature controller board was designed, providing better control with fewer components. Five such boards are used to provide local control of the temperature in various areas of the instrument, improving radiometric performance. The new stepper motor has an embedded controller eliminating the need for a separate controller board. The reference target is heated to avoid possible emissivity (and hence calibration) changes due to moisture contamination in humid environments, as well as avoiding issues with ambient targets during ascent and descent. The radiometer is a double-sideband heterodyne receiver tuned sequentially to individual oxygen emission lines near 60 GHz, with the line selection and intermediate frequency bandwidths chosen to accommodate the altitude range of the aircraft and mission.

  19. Peripheral iridotomy for pigmentary glaucoma

    Science.gov (United States)

    Michelessi, Manuele; Lindsley, Kristina

    2016-01-01

    Background Glaucoma is a chronic optic neuropathy characterized by retinal ganglion cell death resulting in damage to the optic nerve head and the retinal nerve fiber layer. Pigment dispersion syndrome is characterized by a structural disturbance in the iris pigment epithelium (the densely pigmented posterior surface of the iris) that leads to dispersion of the pigment and its deposition on various structures within the eye. Pigmentary glaucoma is a specific form of open-angle glaucoma found in patients with pigment dispersion syndrome. Topcial medical therapy is usually the first-line treatment; however, peripheral laser iridotomy has been proposed as an alternate treatment. Peripheral laser iridotomy involves creating an opening in the iris tissue to allow drainage of fluid from the posterior chamber to the anterior chamber and vice versa. Equalizing the pressure within the eye may help to alleviate the friction that leads to pigment dispersion and prevent visual field deterioration. However, the effectiveness of peripheral laser iridotomy in reducing the development or progression of pigmentary glaucoma is unknown. Objectives The objective of this review was to assess the effects of peripheral laser iridotomy compared with other interventions, including medication, trabeculoplasty, and trabeculectomy, or no treatment, for pigment dispersion syndrome and pigmentary glaucoma. Search methods We searched a number of electronic databases including CENTRAL, MEDLINE and EMBASE and clinical trials websites such as (mRCT) and ClinicalTrials.gov. We last searched the electronic databases on 2 November 2015. Selection criteria We included randomized controlled trials (RCTs) that had compared peripheral laser iridotomy versus no treatment or other treatments for pigment dispersion syndrome and pigmentary glaucoma. Data collection and analysis We used standard methodological procedures for systematic reviews. Two review authors independently screened articles for eligibility

  20. Drug-induced peripheral neuropathy

    DEFF Research Database (Denmark)

    Vilholm, Ole Jakob; Christensen, Alex Alban; Zedan, Ahmed

    2014-01-01

    Peripheral neuropathy can be caused by medication, and various descriptions have been applied for this condition. In this MiniReview, the term 'drug-induced peripheral neuropathy' (DIPN) is used with the suggested definition: Damage to nerves of the peripheral nervous system caused by a chemical...... substance used in the treatment, cure, prevention or diagnosis of a disease. Optic neuropathy is included in this definition. A distinction between DIPN and other aetiologies of peripheral neuropathy is often quite difficult and thus, the aim of this MiniReview is to discuss the major agents associated...

  1. 46 CFR 61.05-15 - Boiler mountings and attachments.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Boiler mountings and attachments. 61.05-15 Section 61.05... TESTS AND INSPECTIONS Tests and Inspections of Boilers § 61.05-15 Boiler mountings and attachments. (a....05-10. (b) Each stud or bolt for each boiler mounting that paragraph (c) of this section requires to...

  2. Organization and processes of the BN-600 reactor mounting

    International Nuclear Information System (INIS)

    Dubrovin, E.Z.; Karpenko, V.N.; Takhtaulov, V.M.

    1982-01-01

    Structural peculiarities of the BN-600 reactor plant are considered. Experience of metal structure mounting inside the reactor vessel has been analysed. Recommendations on the improvements on the organization of the thermal mechanical equipment mounting are given. It is concluded that the consideration of these recommendations will permit to reduce expenditures of labour by 10-40% for the mounting

  3. [The controversy of routine articulator mounting in orthodontics].

    Science.gov (United States)

    Wang, Li; Han, Xianglong; Bai, Ding

    2013-06-01

    Articulators have been widely used by clinicians of dentistry. But routine articulator mounting is still controversial in orthodontics. Orthodontists oriented by gnathology approve routine articulator mounting while nongnathologic orthodontists disapprove it. This article reviews the thoughts of orthodontist that they agree or disagree with routine articulator mounting based on the considerations of biting, temporomandibular disorder (TMD), periodontitis, and so on.

  4. 49 CFR 571.212 - Standard No. 212; Windshield mounting.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 6 2010-10-01 2010-10-01 false Standard No. 212; Windshield mounting. 571.212... Motor Vehicle Safety Standards § 571.212 Standard No. 212; Windshield mounting. S1. Scope. This standard..., under the conditions of S6, the windshield mounting of the vehicle shall retain not less than the...

  5. Altered effector function of peripheral cytotoxic cells in COPD

    Directory of Open Access Journals (Sweden)

    Corne Jonathan M

    2009-06-01

    Full Text Available Abstract Background There is mounting evidence that perforin and granzymes are important mediators in the lung destruction seen in COPD. We investigated the characteristics of the three main perforin and granzyme containing peripheral cells, namely CD8+ T lymphocytes, natural killer (NK; CD56+CD3- cells and NKT-like (CD56+CD3+ cells. Methods Peripheral blood mononuclear cells (PBMCs were isolated and cell numbers and intracellular granzyme B and perforin were analysed by flow cytometry. Immunomagnetically selected CD8+ T lymphocytes, NK (CD56+CD3- and NKT-like (CD56+CD3+ cells were used in an LDH release assay to determine cytotoxicity and cytotoxic mechanisms were investigated by blocking perforin and granzyme B with relevant antibodies. Results The proportion of peripheral blood NKT-like (CD56+CD3+ cells in smokers with COPD (COPD subjects was significantly lower (0.6% than in healthy smokers (smokers (2.8%, p +CD3- cells from COPD subjects were significantly less cytotoxic than in smokers (16.8% vs 51.9% specific lysis, p +CD3+ cells (16.7% vs 52.4% specific lysis, p +CD3- and NKT-like (CD56+CD3+ cells from smokers and HNS. Conclusion In this study, we show that the relative numbers of peripheral blood NK (CD56+CD3- and NKT-like (CD56+CD3+ cells in COPD subjects are reduced and that their cytotoxic effector function is defective.

  6. An Experimental Study of a Sting-Mounted Circulation Control Wing

    Science.gov (United States)

    1991-12-01

    atmospheric pressure was read from a Henry J. Green ML-330/FM mercury barometer and the desired tunnel q was determined from: q.)= 1/2 RTatms (21) F atmos C2...attachment to the Coanda surface. With the model mounted on a bench outside the tunnel, a fixture was attached to the model so that a pitot tube could be...mounted immediately aft of the blowing slot to measure jet total pressure at any point along the trailing edge. The pitot tube was connected to a 50 inch

  7. Peripheral degenerative joint diseases

    Directory of Open Access Journals (Sweden)

    Nilzio Antonio da Silva

    2008-03-01

    Full Text Available Osteoarthritis, a degenerative joint disease, is the most commonrheumatic disorder mainly in a geriatric population. Manifestationsare pain, stiffness and functional loss in the affected joint.According to etiology it is classifi ed as primary (or idiopathicand secondary. Some risk factors for disease development aregenetics, race, age, sex, obesity, occupational activities andarticular biomechanics. Pathogenesis is the same for any cause orlocalization, being catabolic alterations, with synthesis, inhibitionand reparing intent of the cartilage matrix. Metalloproteinases andcytokines (IL-1,IL-6,TNF-α actions promote infl ammatory reactionand cartilage degradation. Pain, the most important symptom,does not correlate with radiologic fi ndings. Peripheral osteoarthritisoccurs predominantly in the knee, hip and hand. Diagnosis is basedon clinical features, laboratorial tests and radiological changes.Rheumatological associations’ guidelines for treatment includenon-pharmacologic (education, physiotherapy, assistive devices,and pharmacologic (analgesics, anti-infl ammatory drugs therapyand surgery. Arthroplasty seems to work better than medicines, butshould be used if other treatments have failed.

  8. MRTouch: Adding Touch Input to Head-Mounted Mixed Reality.

    Science.gov (United States)

    Xiao, Robert; Schwarz, Julia; Throm, Nick; Wilson, Andrew D; Benko, Hrvoje

    2018-04-01

    We present MRTouch, a novel multitouch input solution for head-mounted mixed reality systems. Our system enables users to reach out and directly manipulate virtual interfaces affixed to surfaces in their environment, as though they were touchscreens. Touch input offers precise, tactile and comfortable user input, and naturally complements existing popular modalities, such as voice and hand gesture. Our research prototype combines both depth and infrared camera streams together with real-time detection and tracking of surface planes to enable robust finger-tracking even when both the hand and head are in motion. Our technique is implemented on a commercial Microsoft HoloLens without requiring any additional hardware nor any user or environmental calibration. Through our performance evaluation, we demonstrate high input accuracy with an average positional error of 5.4 mm and 95% button size of 16 mm, across 17 participants, 2 surface orientations and 4 surface materials. Finally, we demonstrate the potential of our technique to enable on-world touch interactions through 5 example applications.

  9. Combat vehicle crew helmet-mounted display: next generation high-resolution head-mounted display

    Science.gov (United States)

    Nelson, Scott A.

    1994-06-01

    The Combat Vehicle Crew Head-Mounted Display (CVC HMD) program is an ARPA-funded, US Army Natick Research, Development, and Engineering Center monitored effort to develop a high resolution, flat panel HMD for the M1 A2 Abrams main battle tank. CVC HMD is part of the ARPA High Definition Systems (HDS) thrust to develop and integrate small (24 micrometers square pels), high resolution (1280 X 1024 X 6-bit grey scale at 60 frame/sec) active matrix electroluminescent (AMEL) and active matrix liquid crystal displays (AMLCD) for head mounted and projection applications. The Honeywell designed CVC HMD is a next generation head-mounted display system that includes advanced flat panel image sources, advanced digital display driver electronics, high speed (> 1 Gbps) digital interconnect electronics, and light weight, high performance optical and mechanical designs. The resulting dramatic improvements in size, weight, power, and cost have already led to program spin offs for both military and commercial applications.

  10. Field-trip guide to Mount Hood, Oregon, highlighting eruptive history and hazards

    Science.gov (United States)

    Scott, William E.; Gardner, Cynthia A.

    2017-06-22

    This guidebook describes stops of interest for a geological field trip around Mount Hood volcano. It was developed for the 2017 International Association of Volcanology and Chemistry of the Earth’s Interior (IAVCEI) Scientific Assembly in Portland, Oregon. The intent of this guidebook and accompanying contributions is to provide an overview of Mount Hood, including its chief geologic processes, magmatic system, eruptive history, local tectonics, and hazards, by visiting a variety of readily accessible localities. We also describe coeval, largely monogenetic, volcanoes in the region. Accompanying the field-trip guidebook are separately authored contributions that discuss in detail the Mount Hood magmatic system and its products and behavior (Kent and Koleszar, this volume); Mount Hood earthquakes and their relation to regional tectonics and the volcanic system (Thelen and Moran, this volume); and young surface faults cutting the broader Mount Hood area whose extent has come to light after acquisition of regional light detection and ranging coverage (Madin and others, this volume).The trip makes an approximately 175-mile (280-kilometer) clockwise loop around Mount Hood, starting and ending in Portland. The route heads east on Interstate 84 through the Columbia River Gorge National Scenic Area. The guidebook points out only a few conspicuous features of note in the gorge, but many other guides to the gorge are available. The route continues south on the Mount Hood National Scenic Byway on Oregon Route 35 following Hood River, and returns to Portland on U.S. Highway 26 following Sandy River. The route traverses rocks as old as the early Miocene Eagle Creek Formation and overlying Columbia River Basalt Group of middle Miocene age, but chiefly lava flows and clastic products of arc volcanism of late Miocene to Holocene age.

  11. A trolley mounted magazine for reactor maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Brennan, P.J.; Madani, M.; Ridgway, G.H. [GE Hitachi Nuclear Energy Canada, Peterborough, Ontario (Canada)], E-mail: patrick1.brennan@ge.com, mehdi.madani@ge.com, guy.ridgway@ge.com; Lundy, E.; Knight, D. [IM and CS (Inspection, Maintenance and Commerical Services), Ontario Power Generation, Ajax, Ontario (Canada)], E-mail: erroll.lundy@opg.com, david.knight@opg.com

    2009-03-15

    This paper describes the design of a mechanism incorporating a rotary magazine to be mounted on a fuelling machine transport trolley for use at a Darlington reactor during a feeder replacement or maintenance outage. The magazine stores reactor channel maintenance components, such as channel isolation plugs and vented closure plugs, in twelve available magazine channels. Use of the magazine rather than a fuelling machine reduces the time required to transfer such components between the Central Service Area and reactor channels. Component transfers are accomplished by locking the fuelling machine onto one of the magazine channels and using a local controller to execute commands received from the fuel handling control system. (author)

  12. A trolley mounted magazine for reactor maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Brennan, P.J.; Madani, M.; Ridgway, G.H., E-mail: patrick1.brennan@ge.com, E-mail: mehdi.madani@ge.com, E-mail: guy.ridgway@ge.com [GE Hitachi Nuclear Energy Canada, Peterborough, Ontario (Canada); Lundy, E.; Knight, D., E-mail: erroll.lundy@opg.com, E-mail: david.knight@opg.com [Ontario Power Generation, Inspection, Maintenance and Commercial Services, Ajax, Ontario (Canada)

    2008-07-01

    This paper describes the design of a mechanism incorporating a rotary magazine to be mounted on a fuelling machine transport trolley for use at a Darlington reactor during a feeder replacement or maintenance outage. The magazine stores reactor channel maintenance components, such as channel isolation plugs and vented closure plugs, in twelve available magazine channels. Use of the magazine rather than a fuelling machine reduces the time required to transfer such components between the Central Service Area and reactor channels. Component transfers are accomplished by locking the fuelling machine onto one of the magazine channels and using a local controller to execute commands received from the fuel handling control system. (author)

  13. A trolley mounted magazine for reactor maintenance

    International Nuclear Information System (INIS)

    Brennan, P.J.; Madani, M.; Ridgway, G.H.; Lundy, E.; Knight, D.

    2009-01-01

    This paper describes the design of a mechanism incorporating a rotary magazine to be mounted on a fuelling machine transport trolley for use at a Darlington reactor during a feeder replacement or maintenance outage. The magazine stores reactor channel maintenance components, such as channel isolation plugs and vented closure plugs, in twelve available magazine channels. Use of the magazine rather than a fuelling machine reduces the time required to transfer such components between the Central Service Area and reactor channels. Component transfers are accomplished by locking the fuelling machine onto one of the magazine channels and using a local controller to execute commands received from the fuel handling control system. (author)

  14. A trolley mounted magazine for reactor maintenance

    International Nuclear Information System (INIS)

    Brennan, P.J.; Madani, M.; Ridgway, G.H.; Lundy, E.; Knight, D.

    2008-01-01

    This paper describes the design of a mechanism incorporating a rotary magazine to be mounted on a fuelling machine transport trolley for use at a Darlington reactor during a feeder replacement or maintenance outage. The magazine stores reactor channel maintenance components, such as channel isolation plugs and vented closure plugs, in twelve available magazine channels. Use of the magazine rather than a fuelling machine reduces the time required to transfer such components between the Central Service Area and reactor channels. Component transfers are accomplished by locking the fuelling machine onto one of the magazine channels and using a local controller to execute commands received from the fuel handling control system. (author)

  15. Radiothermometry indifferential diagnosis of peripheral lung cancer

    International Nuclear Information System (INIS)

    Ginzburg, L.I.; Kogan, E.A.; Yashunskaya, N.I.

    1991-01-01

    Methods of radiothermometry for differential diagnosis of peripheral lung formations using a radiometer operating within 10 cm-wave band were worked out. Altogether 59 patients (of them 45 men) were investigated. Temperature was measured on the chest surface in the area of a lung pathological formation projected on it. Placing its image on the heart and major vessel shadows was avoided. Mean temperature was calculated from 6-8 measurements. Temperature above a peripheral lung tumor was shown to be by 0.5 deg C higher than that of unchanged pulmonary tissue. Benign spheroidal formations (tuberculoma, hamartoma) were characterized by a decrease of 0.6-0.9 deg C as compared to unchanged pulmonary tissue. Comparison of operation of 2 radiometers (the second one operating in the 8 mm-wave band) has shown diagnostic advantages of the first one

  16. Odontogenic keratocyst: a peripheral variant.

    Science.gov (United States)

    Vij, H; Vij, R; Gupta, V; Sengupta, S

    2011-01-01

    Odontogenic keratocyst, which is developmental in nature, is an intraosseous lesion though on rare occasions it may occur in an extraosseous location. The extraosseous variant is referred to as peripheral odontogenic keratocyst. Though, clinically, peripheral odontogenic keratocyst resembles the gingival cyst of adults, it has histologic features that are pathognomonic of odontogenic keratocyst. This article presents a case of this uncommon entity.

  17. Research on LQR optimal control method of active engine mount

    Science.gov (United States)

    Huan, Xie; Yu, Duan

    2018-04-01

    In this paper, the LQR control method is applied to the active mount of the engine, and a six-cylinder engine excitation model is established. Through the joint simulation of AMESim and MATLAB, the vibration isolation performance of the active mount system and the passive mount system is analyzed. Excited by the multi-engine operation, the simulation results of the vertical displacement, acceleration and dynamic deflection of the vehicle body show that the vibration isolation capability of the active mount system is superior to that of the passive mount system. It shows that compared with the passive mount, LQR active mount can greatly improve the vibration isolation performance, which proves the feasibility and effectiveness of the LQR control method.

  18. Peripheral dentinogenic ghost cell tumor

    Directory of Open Access Journals (Sweden)

    Sushant S Kamat

    2013-01-01

    Full Text Available Dentinogenic ghost cell tumors (DGCT are uncommon lesions mainly with rare peripheral types. This report presents a case of peripheral DGCT on the left side of the mandibular alveolar ridge of a heavy smoker, a 68-year-old man, with main presenting feature as a mild pain. Submandibular lymphadenopathy and radiological "saucerization" were evident. Differential diagnosis included fibroma, neurofibroma, peripheral ameloblastoma, peripheral odontogenic fibroma, and peripheral giant cell granuloma. Histologically, ameloblastoma-like epithelial elements were seen in association with grouped ghost cells. Proliferating polyhedral cells and stellate reticulum-like cells with various densities were spread over a wide range of the field. The lesion was curetted and after 2 years of follow up, it did not recur.

  19. Evaluation of shear mounted elastomeric damper

    Science.gov (United States)

    Zorzi, E.; Walton, J.

    1982-01-01

    Viton-70 elastomeric shear mounted damper was built and tested on a T-55 power turbine spool in the rotor's high speed balancing rig. This application of a shear mounted elastomeric damper demonstrated for the first time, the feasibility of using elastomers as the primary rotor damping source in production turbine engine hardware. The shear damper design was selected because it was compatible with actual gas turbine engine radial space constraints, could accommodate both the radial and axial thrust loads present in gas turbine engines, and was capable of controlled axial preload. The shear damper was interchangeable with the production T-55 power turbine roller bearing support so that a direct comparison between the shear damper and the production support structure could be made. Test results show that the Viton-70 elastomer damper operated successfully and provided excellent control of both synchronous and nonsynchronous vibrations through all phases of testing up to the maximum rotor speed of 16,000 rpm. Excellent correlation between the predicted and experienced critical speeds, mode shapes and log decrements for the power turbine rotor and elastomer damper assembly was also achieved.

  20. Experience with HEP analysis on mounted filesystems

    International Nuclear Information System (INIS)

    Fuhrmann, Patrick; Gasthuber, Martin; Kemp, Yves; Ozerov, Dmitry

    2012-01-01

    We present results on different approaches on mounted filesystems in use or under investigation at DESY. dCache, established since long as a storage system for physics data has implemented the NFS v4.1/pNFS protocol. New performance results will be shown with the most current version of the dCache server. In addition to the native usage of the mounted filesystem in a LAN environment, the results are given for the performance of the dCache NFS v4.1/pNFS in WAN case. Several commercial vendors are currently in alpha or beta phase of adding the NFS v4.1/pNFS protocol to their storage appliances. We will test some of these vendor solutions for their readiness for HEP analysis. DESY has recently purchased an IBM Sonas system. We will present the result of a thorough performance evaluation using the native protocols NFS (v3 or v4) and GPFS. As the emphasis is on the usability for end user analysis, we will use latest ROOT versions and current end user analysis code for benchmark scenarios.

  1. Peripheral Auditory Mechanisms

    CERN Document Server

    Hall, J; Hubbard, A; Neely, S; Tubis, A

    1986-01-01

    How weIl can we model experimental observations of the peripheral auditory system'? What theoretical predictions can we make that might be tested'? It was with these questions in mind that we organized the 1985 Mechanics of Hearing Workshop, to bring together auditory researchers to compare models with experimental observations. Tbe workshop forum was inspired by the very successful 1983 Mechanics of Hearing Workshop in Delft [1]. Boston University was chosen as the site of our meeting because of the Boston area's role as a center for hearing research in this country. We made a special effort at this meeting to attract students from around the world, because without students this field will not progress. Financial support for the workshop was provided in part by grant BNS- 8412878 from the National Science Foundation. Modeling is a traditional strategy in science and plays an important role in the scientific method. Models are the bridge between theory and experiment. Tbey test the assumptions made in experim...

  2. Improved resolution by mounting of tissue sections for laser microdissection.

    Science.gov (United States)

    van Dijk, M C R F; Rombout, P D M; Dijkman, H B P M; Ruiter, D J; Bernsen, M R

    2003-08-01

    Laser microbeam microdissection has greatly facilitated the procurement of specific cell populations from tissue sections. However, the fact that a coverslip is not used means that the morphology of the tissue sections is often poor. To develop a mounting method that greatly improves the morphological quality of tissue sections for laser microbeam microdissection purposes so that the identification of target cells can be facilitated. Fresh frozen tissue and formalin fixed, paraffin wax embedded tissue specimens were used to test the morphological quality of mounted and unmounted tissue. The mounting solution consisted of an adhesive gum and blue ink diluted in water. Interference of the mounting solution with DNA quality was analysed by the polymerase chain reaction using 10-2000 cells isolated by microdissection from mounted and unmounted tissue. The mounting solution greatly improved the morphology of tissue sections for laser microdissection purposes and had no detrimental effects on the isolation and efficiency of amplification of DNA. One disadvantage was that the mounting solution reduced the cutting efficiency of the ultraviolet laser. To minimise this effect, the mounting solution should be diluted as much as possible. Furthermore, the addition of blue ink to the mounting medium restores the cutting efficiency of the laser. The mounting solution is easy to prepare and apply and can be combined with various staining methods without compromising the quality of the DNA extracted.

  3. Eruptive history of Mount Katmai, Alaska

    Science.gov (United States)

    Hildreth, Edward; Fierstein, Judith

    2012-01-01

    Mount Katmai has long been recognized for its caldera collapse during the great pyroclastic eruption of 1912 (which vented 10 km away at Novarupta in the Valley of Ten Thousand Smokes), but little has previously been reported about the geology of the remote ice-clad stratovolcano itself. Over several seasons, we reconnoitered all parts of the edifice and sampled most of the lava flows exposed on its flanks and caldera rim. The precipitous inner walls of the 1912 caldera remain too unstable for systematic sampling; so we provide instead a photographic and interpretive record of the wall sequences exposed. In contrast to the several andesite-dacite stratovolcanoes nearby, products of Mount Katmai range from basalt to rhyolite. Before collapse in 1912, there were two overlapping cones with separate vent complexes and craters; their products are here divided into eight sequences of lava flows, agglutinates, and phreatomagmatic ejecta. Latest Pleistocene and Holocene eruptive units include rhyodacite and rhyolite lava flows along the south rim; a major 22.8-ka rhyolitic plinian fall and ignimbrite deposit; a dacite-andesite zoned scoria fall; a thick sheet of dacite agglutinate that filled a paleocrater and draped the west side of the edifice; unglaciated leveed dacite lava flows on the southeast slope; and the Horseshoe Island dacite dome that extruded on the caldera floor after collapse. Pre-collapse volume of the glaciated Katmai edifice was ∼30 km3, and eruptive volume is estimated to have been 57±13 km3. The latter figure includes ∼40±6 km3 for the edifice, 5±2 km3 for off-edifice dacite pyroclastic deposits, and 12±5 km3 for the 22.8-ka rhyolitic pyroclastic deposits. To these can be added 13.5 km3 of magma that erupted at Novarupta in 1912, all or much of which is inferred to have been withdrawn from beneath Mount Katmai. The oldest part of the edifice exposed is a basaltic cone, which gave a 40Ar/39Ar plateau age of 89 ± 25 ka.

  4. Surficial Geology of Mount Rainier National Park, Washington

    Science.gov (United States)

    Crandell, Dwight Raymond

    1969-01-01

    Much of the ground surface around Mount Rainier volcano is directly underlain by loose geologic deposits that veneer the hard rock formations. Examples of these deposits are sand and gravel bars along the rivers, ridges of loose rock debris beside the glaciers, and sloping aprons of rock fragments beneath almost every cliff. Even though they are generally thin and inconspicuous when compared with the rock formations, these surficial deposits are clues to geologic events that have profoundly influenced the shape of the park's landscape. Thus, from the character and extent of glacial deposits one can judge the age and size of former glaciers that carved the cirques and deep canyons of the park; from the mudflows which streamed down nearly every valley one can infer the age and size of huge landslides of the past that helped determine Mount Rainier's present shape; and from the pumice deposits some of the volcano's recent eruptive activity can be reconstructed. The map (plate 1, in pocket) that accompanies this description of the surficial deposits of Mount Rainier National Park shows the location of the various geologic formations, and the explanation shows the formations arranged in order of their relative age, with the oldest at the bottom. The text describes the surficial deposits in sequence from older to younger. A discussion of the pumice deposits of the park, which were not mapped, is followed by a description of the formations shown on the geologic map. Inspection of the geologic map may lead the viewer to question why the surficial deposits are shown in more detail in a zone several miles wide around the base of the volcano than elsewhere. This is partly because the zone is largely near or above timberline, relatively accessible, and the surficial deposits there can be readily recognized, differentiated, and mapped. In contrast, access is more difficult in the heavily timbered parts of the park, and surficial deposits there are generally blanketed by a dense

  5. Full waveform ambient noise tomography of Mount Rainer

    Science.gov (United States)

    Flinders, A. F.; Shen, Y.

    2014-12-01

    Mount Rainier towers over the landscape of western Washington, ranking with Fuji-yama in Japan, Mt. Pinatubo in the Philippines, and Mt. Vesuvius in Italy, as one of the great stratovolcanoes of the world. Notwithstanding it's picturesque stature, Mt. Rainier is potentially the most devastating stratovolcano in North America, with more than 3.5 million people living beneath its shadow in the Seattle-Tacoma area. The primary hazard posed by the volcano is in the form of highly destructive volcanic debris flows (lahars). These lahars form when water and/or melted ice erode away and entrain preexisting volcanic sediment. At Mt. Rainier these flows are often initiated by sector collapse of the volcano's hydrothermally rotten flanks and compounded from Mt. Rainier's extensive snow and glacial ice coverage. It is therefore imperative to ascertain the extent of summit hydrothermal alteration within the volcano, and determine areas prone to collapse. Despite being one of the sixteen volcanoes globally designated by the International Association of Volcanology and Chemistry of the Earth's Interior as warranting detailed and focused study, Mt. Rainier remains enigmatic both in terms of shallow internal structure and the degree of summit hydrothermal alteration. We image this shallow internal structure and areas of possible summit alteration using ambient noise tomography. Our full waveform forward modeling includes high-resolution topography, allowing us to accurately account for the effects of topography on the propagation of short-period Rayleigh waves. Empirical Green's functions were extracted from 80 stations within 200 km of Mount Rainier and compared with synthetic greens functions over multiple frequency bands from 2-28 seconds. The preliminary model shows a broad (60 km wide) low shear-wave velocity anomaly in the mid-crust beneath the volcano. The mid-crust low-velocity body extends to the surface beneath the volcano summit in a narrow near-vertical conduit, the

  6. Auditory attention activates peripheral visual cortex.

    Directory of Open Access Journals (Sweden)

    Anthony D Cate

    Full Text Available BACKGROUND: Recent neuroimaging studies have revealed that putatively unimodal regions of visual cortex can be activated during auditory tasks in sighted as well as in blind subjects. However, the task determinants and functional significance of auditory occipital activations (AOAs remains unclear. METHODOLOGY/PRINCIPAL FINDINGS: We examined AOAs in an intermodal selective attention task to distinguish whether they were stimulus-bound or recruited by higher-level cognitive operations associated with auditory attention. Cortical surface mapping showed that auditory occipital activations were localized to retinotopic visual cortex subserving the far peripheral visual field. AOAs depended strictly on the sustained engagement of auditory attention and were enhanced in more difficult listening conditions. In contrast, unattended sounds produced no AOAs regardless of their intensity, spatial location, or frequency. CONCLUSIONS/SIGNIFICANCE: Auditory attention, but not passive exposure to sounds, routinely activated peripheral regions of visual cortex when subjects attended to sound sources outside the visual field. Functional connections between auditory cortex and visual cortex subserving the peripheral visual field appear to underlie the generation of AOAs, which may reflect the priming of visual regions to process soon-to-appear objects associated with unseen sound sources.

  7. Rack assembly for mounting solar modules

    Science.gov (United States)

    Plaisted, Joshua Reed; West, Brian

    2010-12-28

    A rack assembly is provided for mounting solar modules over an underlying body. The rack assembly may include a plurality of rail structures that are arrangeable over the underlying body to form an overall perimeter for the rack assembly. One or more retention structures may be provided with the plurality of rail structures, where each retention structure is configured to support one or more solar modules at a given height above the underlying body. At least some of the plurality of rail structures are adapted to enable individual rail structures o be sealed over the underlying body so as to constrain air flow underneath the solar modules. Additionally, at least one of (i) one or more of the rail structures, or (ii) the one or more retention structures are adjustable so as to adapt the rack assembly to accommodate solar modules of varying forms or dimensions.

  8. Article mounting and position adjustment stage

    Science.gov (United States)

    Cutburth, Ronald W.; Silva, Leonard L.

    1988-01-01

    An improved adjustment and mounting stage of the type used for the detection of laser beams is disclosed. A ring sensor holder has locating pins on a first side thereof which are positioned within a linear keyway in a surrounding housing for permitting reciprocal movement of the ring along the keyway. A rotatable ring gear is positioned within the housing on the other side of the ring from the linear keyway and includes an oval keyway which drives the ring along the linear keyway upon rotation of the gear. Motor-driven single-stage and dual (x, y) stage adjustment systems are disclosed which are of compact construction and include a large laser transmission hole.

  9. MOUNT HOOD WILDERNESS AND ADJACENT AREAS, OREGON.

    Science.gov (United States)

    Keith, T.E.C.; Causey, J.D.

    1984-01-01

    A mineral survey of the Mount Hood Wilderness, Oregon, was conducted. Geochemical data indicate two areas of substantiated mineral-resource potential containing weak epithermal mineralization: an area of the north side of Zigzag Mountain where vein-type lead-zinc-silver deposits occur and an area of the south side of Zigzag Mountain, where the upper part of a quartz diorite pluton has propylitic alteration associated with mineralization of copper, gold, silver, lead, and zinc in discontinuous veins. Geothermal-resource potential for low- to intermediate-temperature (less than 248 degree F) hot-water systems in the wilderness is probable in these areas. Part of the wilderness is classified as a Known Geothermal Resource Area (KGRA), which is considered to have probable geothermal-resource potential, and two parts of the wilderness have been included in geothermal lease areas.

  10. Insectivore Plants Nepenthes sp. at Mount Merbabu

    Directory of Open Access Journals (Sweden)

    AHMAD DWI SETYAWAN

    2000-07-01

    Full Text Available The aims of the research were to know the existence of the Nepenthes at mount Merbabu, variations of its morphology, associated plants, and ecological conditions. Nepenthes are one of plants that were categorized as conserved plant by Indonesian government as indicated in PPRI No. 7/1999. Many researchers attracted to study this unique plant since it’s distinct feature and the way to get nutrient by trapping insects at its sac. Samples were taken randomly along the path for climbing from Selo, Boyolali to the top of the mountain between April to May 2000. The results show that the plants were found at the altitude of around 1500 to 2000 tsl. There were two forms of the sacs, long and short at the same individual plants. The plants grow coiling on Myristica trees and shrubs of Thunbergia fragrans Roxb., and also could grow at the stoned-soil.

  11. MOUNT PELE, AN ECOCLIMATIC GRADIENT GENERATOR

    Directory of Open Access Journals (Sweden)

    PHILIPPE JOSEPH

    2013-05-01

    Full Text Available Generally, mountains determine the characteristics of particular areas, because of the island phenomenon they cause. However, the geological origins of mountains are multiple and they are located in different climatic regions. Nevertheless, in all aspects they reflect the basic elements of the local biologic unit. The shapes, climates, diverse water resources, biocenoses and the generated soils are the different components that determine, through their dynamic interaction, the “Mountain” ecosystem. Tectonic subduction processes lead to the development of islands such as Martinique, whose basic structure consists of a series of mountains (among them Mount Pele. Like the topographic divisions, the local micro-climates, water courses, different soils (themselves the consequences of the presence of the mountain itself and successive volcanic eruptions determine, over time, the organization of the diverse vegetal entities.

  12. Peripheral T-Cell Lymphoma

    Science.gov (United States)

    ... Non-Hodgkin Lymphoma Peripheral T-Cell Lymphoma Primary Central Nervous System Lymphoma T-Cell Lymphoma Transformed Mycosis Fungoides Waldenstrom Macroglobulinemia Young Adult Lymphoma Overview Treatment Options Relapsed/Refractory Long-term ...

  13. Network node for peripheral sharing

    International Nuclear Information System (INIS)

    Bobbitt, J.; Johnson, M.

    1977-01-01

    A module which enables several independent computer systems to share the peripherals (graphics display and line printer) of a PDP-11 computer is described. The module requires no software support in the PDP-11

  14. Large Peripheral Osteoma of the Mandible: A Case Report

    Directory of Open Access Journals (Sweden)

    Emel Bulut

    2010-01-01

    Full Text Available Osteomas are benign, slow-growing osteogenic tumors commonly occurring in the craniofacial bones. Osteomas are characterized by the proliferation of compact and/or cancellous bone. It can be of a central, peripheral, or extraskeletal type. The peripheral type arises from the periosteum and is rarely seen in the mandible. The lingual surface and lower border of the body are the most common locations of these lesions. They are usually asymptomatic and can be discovered in routine clinical and radiographic examination. In this paper, we presented a large solitary peripheral osteoma located in the buccal surface of the left posterior mandible and causing facial deformity in a 37-year-old woman. Radiographic examination by computed tomography revealed radiopacity with a well-circumscribed, pedunculated mass approximately 3 cm in size. The osteoma was removed surgically, and no recurrence has been observed.

  15. A novel triple-actuating mechanism of an active air mount for vibration control of precision manufacturing machines: experimental work

    International Nuclear Information System (INIS)

    Kim, Hyung-Tae; Kim, Cheol-Ho; Choi, Seung-Bok; Moon, Seok-Jun; Song, Won-Gil

    2014-01-01

    With the goal of vibration control and isolation in a clean room, we propose a new type of air mount which consists of pneumatic, electromagnetic (EM), and magnetorheological (MR) actuators. The air mount is installed below a semiconductor manufacturing machine to reduce the adverse effects caused by unwanted vibration. The proposed mechanism integrates the forces in a parallel connection of the three actuators. The MR part is designed to operate in an air spring in which the EM part is installed. The control logic is developed with a classical method and a switching mode to avoid operational mismatch among the forces developed. Based on extended microprocessors, a portable, embedded controller is installed to execute both nonlinear logic and digital communication with the peripherals. The pneumatic forces constantly support the heavy weight of an upper structure and maintain the level of the air mount. The MR damper handles the transient response, while the EM controller reduces the resonance response, which is switched mutually with a threshold. Vibration is detected by laser displacement sensors which have submicron resolution. The impact test results of three tons load weight demonstrate practical feasibility by showing that the proposed triple-actuating mechanism can reduce the transient response as well as the resonance in the air mount, resulting in accurate motion of the semiconductor manufacturing machine. (technical note)

  16. Mount Ararat, Turkey, Perspective with Landsat Image Overlay

    Science.gov (United States)

    2004-01-01

    This perspective view shows Mount Ararat in easternmost Turkey, which has been the site of several searches for the remains of Noah's Ark. The main peak, known as Great Ararat, is the tallest peak in Turkey, rising to 5165 meters (16,945 feet). This southerly, near horizontal view additionally shows the distinctly conically shaped peak known as 'Little Ararat' on the left. Both peaks are volcanoes that are geologically young, but activity during historic times is uncertain.This image was generated from a Landsat satellite image draped over an elevation model produced by the Shuttle Radar Topography Mission (SRTM). The view uses a 1.25-times vertical exaggeration to enhance topographic expression. Natural colors of the scene are enhanced by image processing, inclusion of some infrared reflectance (as green) to highlight the vegetation pattern, and inclusion of shading of the elevation model to further highlight the topographic features. Volcanoes pose hazards for people, the most obvious being the threat of eruption. But other hazards are associated with volcanoes too. In 1840 an earthquake shook the Mount Ararat region, causing an unstable part of mountain's north slope to tumble into and destroy a village. Visualizations of satellite imagery when combined with elevation models can be used to reveal such hazards leading to disaster prevention through improved land use planning.But the hazards of volcanoes are balanced in part by the benefits they provide. Over geologic time volcanic materials break down to form fertile soils. Cultivation of these soils has fostered and sustained civilizations, as has occurred in the Mount Ararat region. Likewise, tall volcanic peaks often catch precipitation, providing a water supply to those civilizations. Mount Ararat hosts an icefield and set of glaciers, as seen here in this late summer scene, that are part of this beneficial natural processElevation data used in this image was acquired by the Shuttle Radar Topography Mission

  17. Local Community Entrepreneurship in Mount Agung Trekking

    Science.gov (United States)

    Mudana, I. G.; Sutama, I. K.; Widhari, C. I. S.

    2018-01-01

    Since its last major eruption in 1963, Mount Agung in Selat District, Karangasem Regency, the highest mountain in Bali Province began to be visited by tourists climbers. Because of the informal obligation that every climbing/trekking should be guided by local guides, since the 1990s, there have been initiatives from a number of local community members to serve climbing tourists who were keen to climb the volcano/mountain. This study was conducted to understand and describe the entrepreneurial practices which appeared in the local surrounding community. Specifically, Selat Village, in guiding the climbing/trekking. This study used qualitative data analysis and its theories were adapted to data needed in the field. The results of study showed that Mount Agung was considered attractive by climbing tourists not only because of the exotic beauty and challenges of difficulty (as well as the level of danger) to conquer it, but also because it kept certain myths from its status as a holy/sacred mountain to Balinese Hindus. In fact, a number of tourists who did the climbing/trekking without being guided very often got lost, harmed in an accident, or fell to their death. As a direct result, all climbing activities require guidance. Especially guides from local community organizations who really understand the intricacies of climbing and the curvature of the mountain. The entrepreneurial practices of Selat Village community had arisen not only to serve usual climbing activities, but also to preserve the environment of the mountain and the safety of the climbing tourists with the many taboos related to the climb. These facts could be seen clearly from descriptions of local experts and local climbing guides who have been doing their work for years. As a form of entrepreneurship, they basically did their work for the main purpose of seeking livelihoods (or making money) but their responsibility as local people made them commit to guarding the sanctity of the mountain. This was

  18. Photovoltaic array mounting apparatus, systems, and methods

    Science.gov (United States)

    West, Jack Raymond; Atchley, Brian; Hudson, Tyrus Hawkes; Johansen, Emil

    2016-01-05

    A photovoltaic array, including: (a) supports laid out on a surface in rows and columns; (b) photovoltaic modules positioned on top of the supports; and (c) fasteners connecting the photovoltaic modules to the supports, wherein the supports have an upper pedestal surface and a lower pedestal surface such that the photovoltaic modules are positioned at a non-horizontal angle when edges of the photovoltaic modules are positioned on top of the upper and lower pedestal surfaces, and wherein a portion of the fasteners rotate to lock the photovoltaic modules onto the supports.

  19. Vascularization of the dorsal root ganglia and peripheral nerve of the mouse: Implications for chemical-induced peripheral sensory neuropathies

    Directory of Open Access Journals (Sweden)

    Melemedjian Ohannes K

    2008-03-01

    Full Text Available Abstract Although a variety of industrial chemicals, as well as several chemotherapeutic agents used to treat cancer or HIV, preferentially induce a peripheral sensory neuropathy what remains unclear is why these agents induce a sensory vs. a motor or mixed neuropathy. Previous studies have shown that the endothelial cells that vascularize the dorsal root ganglion (DRG, which houses the primary afferent sensory neurons, are unique in that they have large fenestrations and are permeable to a variety of low and high molecular weight agents. In the present report we used whole-mount preparations, immunohistochemistry, and confocal laser scanning microscopy to show that the cell body-rich area of the L4 mouse DRG has a 7 fold higher density of CD31+ capillaries than cell fiber rich area of the DRG or the distal or proximal aspect of the sciatic nerve. This dense vascularization, coupled with the high permeability of these capillaries, may synergistically contribute, and in part explain, why many potentially neurotoxic agents preferentially accumulate and injure cells within the DRG. Currently, cancer survivors and HIV patients constitute the largest and most rapidly expanding groups that have chemically induced peripheral sensory neuropathy. Understanding the unique aspects of the vascularization of the DRG and closing the endothelial fenestrations of the rich vascular bed of capillaries that vascularize the DRG before intravenous administration of anti-neoplastic or anti-HIV therapies, may offer a mechanism based approach to attenuate these chemically induced peripheral neuropathies in these patients.

  20. Virtual sine arm kinematic mount system

    International Nuclear Information System (INIS)

    Xu, Z.; Randall, K.J.

    1997-01-01

    A novel kinematic mount system for a vertical focusing mirror of the soft x-ray spectroscopy beamline at the Advanced Photon Source is described. The system contains three points in a horizontal plane. Each point consists of two horizontal linear precision stages, a spherical ball bearing, and a vertical precision stage. The horizontal linear stages are aligned orthogonally and are conjoined by a spherical ball bearing, supported by the vertical linear stage at each point. The position of each confined horizontal stage is controlled by a motorized micrometer head by spring-loading the flat tip of the micrometer head onto a tooling ball fixing on the carriage of the stage. A virtual sine arm is formed by tilting the upstream horizontal stage down and the two downstream horizontal stages up by a small angle. The fine pitch motion is achieved by adjusting the upstream stage. This supporting structure is extremely steady due to a relatively large span across the supporting points and yields extremely high resolution on the pitch motion. With a one degree tilt and a microstepping motor, the authors achieved a 0.4 nanoradian resolution on the mirror pitch motion

  1. Geological interpretation of Mount Ciremai geothermal system from remote sensing and magneto-teluric analysis

    OpenAIRE

    Sumintadireja, Prihadi; Saepuloh, Asep; Irawan, Dasapta E.; Irawan, Diky; Fadillah, Ahmad

    2014-01-01

    The exploration of geothermal system at Mount Ciremai has been started since the early 1980s and has just been studied carefully since the early 2000s. Previous studies have detected the potential of geothermal system and also the groundwater mechanism feeding the system. This paper will discuss the geothermal exploration based on regional scale surface temperature analysis with Landsat image to have a more detail interpretation of the geological setting and magneto-telluric or MT survey at p...

  2. Geothermal Potential Analysis Using Landsat 8 and Sentinel 2 (Case Study: Mount Ijen)

    Science.gov (United States)

    Sukojo, B. M.; Mardiana, R.

    2017-12-01

    Geothermal energy is also a heat energy contained in the earth’s internal. Indonesia has a total geothermal potential of around 27 GWe. The government is eager for the development of geothermal in Indonesia can run well so that geothermal can act as one of the pillars of national energy. However, the geothermal potential has not been fully utilized. One of the geothermal potention is Mount Ijen. Mount Ijen is a strato volcano that has a crater lake with a depth of about 190 m and has a very high degree of acidity and the volume of lake water is very large. With the abundance of potential geothermal potential in Indonesia, it is necessary to have an activity in the form of integrated geoscience studies to be able to maximize the potential content that exists in a geothermal area. One of the studies conducted is to do potential mapping. This research performs image data processing of Landsat 8, Sentinel 2, RBI Map, and preliminary survey data. This research carried out the Vegetation Index, surface temperature and altitude. The equipment used in this research includes image processing software, number processing software, GPS Handheld and Laptop. Surface Temperatures in the Mount Ijen have anomalies with large temperatures ranging between 18° C to 38° C. The best correlation value of altitude and ground surface temperature is -0.89 ie the correlation of January surface temperature. While the correlation value of Landsat 8 and Sentinel 2 vegetation index was 0.81. The land cover confidence matrix scored 80%. Land cover in the research area is dominated by forests by 35% of the research area. There is a potential area of geothermal potential is very high on Mount Ijen with an area of 39.43 hectares located in Wongsorejo District and adjacent to District Sempol.

  3. Alternative mounting media for preservation of some protozoa.

    Science.gov (United States)

    Criado-Fornelio, A; Heredero-Bermejo, I; Pérez-Serrano, J

    2014-10-01

    Protozoa resistant stages are disintegrated when mounted in toluene-based media. To overcome such problem, three toluene-free mountants were tested on preserve Acanthamoeba spp and gregarines. Two commercial glues based on cyanoacrylate or trimethoxysilane were suitable for preserving both cysts and trophozoites. Hoyer's medium showed good results for mounting gregarine oocysts. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Solar electricity potentials and optimal angles for mounting solar ...

    African Journals Online (AJOL)

    The need for harnessing solar energy using solar panels mounted at optimal inclination angles in the six geopolitical zones of Nigeria is presented. The optimal angle for mounting solar panels as presented by Photovoltaic Geographic Information System (PVGIS) ranges from 11º to 14º in the Southern zone and 13º to 16º ...

  5. Wind instrument mountings for above-the-cab lookout exposure

    Science.gov (United States)

    Owen P. Cramer; Ralph H. Moltzau

    1968-01-01

    The lookout tower offers a ready-made platform from which the speed of true unobstructed wind can be measured, then reduced to equivalent of 20-foot wind. Tower-mounted instruments must meet the requirements of a lightning conductor system, but should also be easily installed and removed for storage and maintenance. Lightweight aluminum mountings for catwalk or flat-...

  6. The alpine flora of Mount Wilhelm (New Guinea)

    NARCIS (Netherlands)

    Hoogland, R.D.

    1958-01-01

    The flora of the higher mountains of New Guinea has been the object of several extensive collecting trips in the past forty years. Until quite recently, however, a serious gap in our knowledge was the very scanty information available from the area between Mount Wilhelmina in the West and Mount

  7. Peripheral giant cell granuloma: A review of 123 cases

    Directory of Open Access Journals (Sweden)

    Niloofar Shadman

    2009-01-01

    Full Text Available Background: Peripheral giant cell granuloma is one of the reactive hyperplastic lesions of the oral cavity, which originates from the periosteum or periodontal membrane following local irritation or chronic trauma. The purpose of this study was to present the clinical characteristics of peripheral gi-ant cell granuloma in a group of Iranian population. Methods: A series of 123 consecutive confirmed cases of peripheral giant cell granuloma after biopsy were evaluated. Age, sex, anatomic location, consistency, etiologic factor, pain and bleeding history, color, surface texture, and pedicle situation were recorded and were analyzed by chi-square test and values were considered to be significant if P < 0.05. Results: Age ranged from 6 to 75 years (mean 33 years. Women affected more than men (M/F 1:1.1. Peripheral giant cell granuloma was seen in the mandible more than in the maxilla and in the anterior region more than in the posterior region. In most cases, lesions were pink, pedunculated and had non-ulcerated surface. In less than half of the cases, there was no history of bleeding and also pain was rarely reported. Calculus was the most common etiologic factor. Conclusion: The results confirmed that the clinical features of peripheral giant cell granuloma in a group of Iranian population are almost similar to those reported by other investigators.

  8. Optimization of Classical Hydraulic Engine Mounts Based on RMS Method

    Directory of Open Access Journals (Sweden)

    J. Christopherson

    2005-01-01

    Full Text Available Based on RMS averaging of the frequency response functions of the absolute acceleration and relative displacement transmissibility, optimal parameters describing the hydraulic engine mount are determined to explain the internal mount geometry. More specifically, it is shown that a line of minima exists to define a relationship between the absolute acceleration and relative displacement transmissibility of a sprung mass using a hydraulic mount as a means of suspension. This line of minima is used to determine several optimal systems developed on the basis of different clearance requirements, hence different relative displacement requirements, and compare them by means of their respective acceleration and displacement transmissibility functions. In addition, the transient response of the mount to a step input is also investigated to show the effects of the optimization upon the time domain response of the hydraulic mount.

  9. Peripheral nerve conduits: technology update

    Science.gov (United States)

    Arslantunali, D; Dursun, T; Yucel, D; Hasirci, N; Hasirci, V

    2014-01-01

    Peripheral nerve injury is a worldwide clinical problem which could lead to loss of neuronal communication along sensory and motor nerves between the central nervous system (CNS) and the peripheral organs and impairs the quality of life of a patient. The primary requirement for the treatment of complete lesions is a tension-free, end-to-end repair. When end-to-end repair is not possible, peripheral nerve grafts or nerve conduits are used. The limited availability of autografts, and drawbacks of the allografts and xenografts like immunological reactions, forced the researchers to investigate and develop alternative approaches, mainly nerve conduits. In this review, recent information on the various types of conduit materials (made of biological and synthetic polymers) and designs (tubular, fibrous, and matrix type) are being presented. PMID:25489251

  10. Banner clouds observed at Mount Zugspitze

    Directory of Open Access Journals (Sweden)

    V. Wirth

    2012-04-01

    Full Text Available Systematic observations of banner clouds at Mount Zugspitze in the Bavarian Alps are presented and discussed. One set of observations draws on daily time lapse movies, which were taken over several years at this mountain. Identifying banner clouds with the help of these movies and using simultaneous observations of standard variables at the summit of the mountain provides climatological information regarding the banner clouds. In addition, a week-long measurement campaign with an entire suite of instruments was carried through yielding a comprehensive set of data for two specific banner cloud events.

    The duration of banner cloud events has a long-tailed distribution with a mean of about 40 min. The probability of occurrence has both a distinct diurnal and a distinct seasonal cycle, with a maximum in the afternoon and in the warm season, respectively. These cycles appear to correspond closely to analogous cycles of relative humidity, which maximize in the late afternoon and during the warm season. In addition, the dependence of banner cloud occurrence on wind speed is weak. Both results suggest that moisture conditions are a key factor for banner cloud occurrence. The distribution of wind direction during banner cloud events slightly deviates from climatology, suggesting an influence from the specific Zugspitz orography.

    The two banner cloud events during the campaign have a number of common features: the windward and the leeward side are characterized by different wind regimes, however, with mean upward flow on both sides; the leeward air is both moister and warmer than the windward air; the background atmosphere has an inversion just above the summit of Mt. Zugspitze; the lifting condensation level increases with altitude. The results are discussed, and it is argued that they are consistent with previous Large Eddy Simulations using idealized orography.

  11. Gravity Probe B Detector Mount Assembly

    Science.gov (United States)

    2004-01-01

    In this photo, the Gravity Probe B (GP-B) detector mount assembly is shown in comparison to the size of a dime. The assembly is used to detect exactly how much starlight is coming through different beams from the beam splitter in the telescope. The measurements from the tiny chips inside are what keeps GP-B aimed at the guide star. The GP-B is the relativity experiment developed at Stanford University to test two extraordinary predictions of Albert Einstein's general theory of relativity. The experiment will measure, very precisely, the expected tiny changes in the direction of the spin axes of four gyroscopes contained in an Earth-orbiting satellite at a 400-mile altitude. So free are the gyroscopes from disturbance that they will provide an almost perfect space-time reference system. They will measure how space and time are very slightly warped by the presence of the Earth, and, more profoundly, how the Earth's rotation very slightly drags space-time around with it. These effects, though small for the Earth, have far-reaching implications for the nature of matter and the structure of the Universe. GP-B is among the most thoroughly researched programs ever undertaken by NASA. This is the story of a scientific quest in which physicists and engineers have collaborated closely over many years. Inspired by their quest, they have invented a whole range of technologies that are already enlivening other branches of science and engineering. Launched April 20, 2004 , the GP-B program was managed for NASA by the Marshall Space Flight Center. Development of the GP-B is the responsibility of Stanford University along with major subcontractor Lockheed Martin Corporation. (Image credit to Paul Ehrensberger, Stanford University.)

  12. Installation of a Roof Mounted Photovoltaic System

    Science.gov (United States)

    Lam, M.

    2015-12-01

    In order to create a safe and comfortable environment for students to learn, a lot of electricity, which is generated from coal fired power plants, is used. Therefore, ISF Academy, a school in Hong Kong with approximately 1,500 students, will be installing a rooftop photovoltaic (PV) system with 302 solar panels. Not only will these panels be used to power a classroom, they will also serve as an educational opportunity for students to learn about the importance of renewable energy technology and its uses. There were four different options for the installation of the solar panels, and the final choice was made based on the loading capacity of the roof, considering the fact that overstressing the roof could prove to be a safety hazard. Moreover, due to consideration of the risk of typhoons in Hong Kong, the solar panel PV system will include concrete plinths as counterweights - but not so much that the roof would be severely overstressed. During and after the installation of the PV system, students involved would be able to do multiple calculations, such as determining the reduction of the school's carbon footprint. This can allow students to learn about the impact renewable energy can have on the environment. Another project students can participate in includes measuring the efficiency of the solar panels and how much power can be produced per year, which in turn can help with calculate the amount of money saved per year and when we will achieve economic parity. In short, the installation of the roof mounted PV system will not only be able to help save money for the school but also provide learning opportunities for students studying at the ISF Academy.

  13. Quasi-optical grill mounted in hyperguide

    International Nuclear Information System (INIS)

    Preinhaelter, J.

    1995-04-01

    A proposal is given of a new launcher of lower hybrid waves for the current drive in future big thermonuclear facilities operating in the 10 GHz frequency range. The principle has been combined of the quasi-optical grill with the concepts of the hyperguide and the multiinjection grill. As an example, a six rod structure model was optimized mounted in a oversized waveguide and irradiated by the oblique plane wave emerging in the form of a higher mode from an auxiliary oversized waveguide. The rods of the optimum structure have the elongated form of the cross-section with the resonant length in the direction of wave propagation equal to a multiple of the half-wavelength of the fundamental mode of the hyperguide. This row of rods forms a multiinjection grill with zero phase shift between waveguides. The second row of rods supporting the constructive superposition of the incident and doubly reflected waves enhances the efficiency of the structure. The optimum structure has a power spectrum with narrow peaks (the main N || =-2.15 and the parasitic N || =3.15), low power reflection (R tot =15%), high coupled power directivity (δ CP =70%), reasonable N || -weighted directivity (|δ CD w |=35%) and the peaking factor on the electric field equal to 3. Based on the optimization it is possible to design parameters of a big structure with tens of rods. The number of the construction elements of the structure can be reduced 20 times compared with the standard multijunction array. (author) 14 figs., 22 refs

  14. Peripheral Atherectomy: Applications and Techniques.

    Science.gov (United States)

    Mittleider, Derek; Russell, Erich

    2016-06-01

    Peripheral atherectomy is a class of procedures that is rapidly increasing in volume. Multiple classes of devices exist, and newer variants are added to the market annually. The devices see wide application for de novo lesions, in-stent restenosis, and adjunctive therapy for drug-coated balloons. The body of evidence supporting atherectomy is less robust than for many other peripheral therapies. The frequency and severity of complications from atherectomy can be significant compared with angioplasty and stenting, and familiarity with preventative and bailout techniques is essential for the interventionalist. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. [Atherectomy for peripheral arterial disease].

    Science.gov (United States)

    Londero, Louise Skovgaard; Høgh, Annette Langager; Lindholt, Jes Sanddal

    2015-04-13

    Symptomatic peripheral arterial disease is managed according to national and international guidelines and the number of vascular reconstructions performed each year has increased over the past decade mainly due to an increasing frequency of endovascular procedures. Atherectomy as an alternative to the established treatment of symptomatic peripheral arterial disease has recently been analysed in a Cochrane review. In Denmark, atherectomy is not performed and so far the evidence is poor as the method is not an alternative to the established treatment in this country.

  16. Imaging of the peripheral retina

    Directory of Open Access Journals (Sweden)

    Marcus Kernt

    2013-01-01

    Full Text Available The technical progress of the recent years has revolutionized imaging in ophthalmology. Scanning laser ophthalmoscopy (SLO, digital angiography, optical coherence tomography (OCT, and detection of fundus autofluorescence (FAF have fundamentally changed our understanding of numerous retinal and choroidal diseases. Besides the tremendous advances in macular diagnostics, there is more and more evidence that central pathologies are often directly linked to changes in the peripheral retina. This review provides a brief overview on current posterior segment imaging techniques with a special focus on the peripheral retina.

  17. Optimized Whole-Mount In Situ Immunolocalization for Arabidopsis thaliana Root Meristems and Lateral Root Primordia.

    Science.gov (United States)

    Karampelias, Michael; Tejos, Ricardo; Friml, Jiří; Vanneste, Steffen

    2018-01-01

    Immunolocalization is a valuable tool for cell biology research that allows to rapidly determine the localization and expression levels of endogenous proteins. In plants, whole-mount in situ immunolocalization remains a challenging method, especially in tissues protected by waxy layers and complex cell wall carbohydrates. Here, we present a robust method for whole-mount in situ immunolocalization in primary root meristems and lateral root primordia in Arabidopsis thaliana. For good epitope preservation, fixation is done in an alkaline paraformaldehyde/glutaraldehyde mixture. This fixative is suitable for detecting a wide range of proteins, including integral transmembrane proteins and proteins peripherally attached to the plasma membrane. From initiation until emergence from the primary root, lateral root primordia are surrounded by several layers of differentiated tissues with a complex cell wall composition that interferes with the efficient penetration of all buffers. Therefore, immunolocalization in early lateral root primordia requires a modified method, including a strong solvent treatment for removal of hydrophobic barriers and a specific cocktail of cell wall-degrading enzymes. The presented method allows for easy, reliable, and high-quality in situ detection of the subcellular localization of endogenous proteins in primary and lateral root meristems without the need of time-consuming crosses or making translational fusions to fluorescent proteins.

  18. High-resolution radon monitoring and hydrodynamics at Mount Vesuvius

    Science.gov (United States)

    Cigolini, Corrado; Salierno, Francesco; Gervino, Gianpiero; Bergese, Paolo; Marino, Ciro; Russo, Massimo; Prati, Paolo; Ariola, Vincenzo; Bonetti, Roberto; Begnini, Stefania

    A yearlong high-resolution radon survey has been carried on at Mount Vesuvius, starting in May 1998. Radon activities were acquired by exposing charcoal canisters and track-etch detectors. Sampling stations were deployed along two major summit faults and around the caldera bottom. Volcanically-related earthquakes, with MD ≥ 2.5, may be discriminated from regional seismic events since their cumulative radon anomalies are recorded from stations located along all the above structural features. On the contrary, radon anomalies correlated to regional earthquakes, with MD ≥ 4, are essentially recorded by the sampling sites located along the two summit faults (whose roots extend deeper into the Tertiary basement rocks that underlay the volcano). Radon migration to the surface is ruled by convection within a porous medium of relatively low porosity (ϕ ≈ 10-5), suggesting that fluid motion is strongly localised along fractures. It is suggested that fluid pressure build up, followed by fluid release and migration during incipient fracturing of the porous medium, precede the onset of volcanically-induced earthquakes.

  19. Snow observations in Mount Lebanon (2011-2016)

    Science.gov (United States)

    Fayad, Abbas; Gascoin, Simon; Faour, Ghaleb; Fanise, Pascal; Drapeau, Laurent; Somma, Janine; Fadel, Ali; Bitar, Ahmad Al; Escadafal, Richard

    2017-08-01

    We present a unique meteorological and snow observational dataset in Mount Lebanon, a mountainous region with a Mediterranean climate, where snowmelt is an essential water resource. The study region covers the recharge area of three karstic river basins (total area of 1092 km2 and an elevation up to 3088 m). The dataset consists of (1) continuous meteorological and snow height observations, (2) snowpack field measurements, and (3) medium-resolution satellite snow cover data. The continuous meteorological measurements at three automatic weather stations (MZA, 2296 m; LAQ, 1840 m; and CED, 2834 m a.s.l.) include surface air temperature and humidity, precipitation, wind speed and direction, incoming and reflected shortwave irradiance, and snow height, at 30 min intervals for the snow seasons (November-June) between 2011 and 2016 for MZA and between 2014 and 2016 for CED and LAQ. Precipitation data were filtered and corrected for Geonor undercatch. Observations of snow height (HS), snow water equivalent, and snow density were collected at 30 snow courses located at elevations between 1300 and 2900 m a.s.l. during the two snow seasons of 2014-2016 with an average revisit time of 11 days. Daily gap-free snow cover extent (SCA) and snow cover duration (SCD) maps derived from MODIS snow products are provided for the same period (2011-2016). We used the dataset to characterize mean snow height, snow water equivalent (SWE), and density for the first time in Mount Lebanon. Snow seasonal variability was characterized with high HS and SWE variance and a relatively high snow density mean equal to 467 kg m-3. We find that the relationship between snow depth and snow density is specific to the Mediterranean climate. The current model explained 34 % of the variability in the entire dataset (all regions between 1300 and 2900 m a.s.l.) and 62 % for high mountain regions (elevation 2200-2900 m a.s.l.). The dataset is suitable for the investigation of snow dynamics and for the forcing

  20. Cinder cones of Mount Slamet, Central Java, Indonesia

    Directory of Open Access Journals (Sweden)

    Igan S. SutawIdjaja

    2014-06-01

    Full Text Available http://dx.doi.org/10.17014/ijog.vol4no1.20096The Mount Slamet volcanic field in Central Java, Indonesia, contains thirty five cinder cones within an area of 90 sq. km in the east flank of the volcano. The cinder cones occur singly or in small groups, with diameter of the base ranges from 130 - 750 m and the height is around 250 m. Within the volcanic field, the cinder cones are spread over the volcanic area at the distance of 4 to 14 km from the eruption center of the Slamet Volcano. They are concentrated within latitudes 7°11’00” - 7°16’00” S,, and longitudes 109°15’00” - 109°18’00” E. The density of the cinder cones is about 1.5 cones/km2. Most of the cinder cones lie on the Tertiary sedimentary rocks along the NW-trending fault system and on radial fractures. The structural pattern may be related to the radial faults in this region. The cone surfaces are commonly blanketed by Slamet air-falls and lava flows. The deposits consist of poorly bedded, very coarse-grained, occasionally overlain by oxidized scoria, and large-sized of ballistic bombs and blocks. There are various kind of volcanic bombs originating from scoriae ballistic rock fragments. The other kind of volcanic bombs are breadcrust bomb, almond seed or contorted shape. All of the cinder cones have undergone degradation, which can be observed from the characters of gully density and surface morphology. By using Porter parameters, Hco is equal to 0.25 Wco, whilst Wcr is equal to 0.40 Wco. The Hco/Wco ratio is higher than Hco = 0.2 Wco reference line. A radiometric dating using K-Ar method carried out on a scoria bomb yields the age of 0.042 + 0.020 Ma.  

  1. Apparent Brecciation Gradient, Mount Desert Island, Maine

    Science.gov (United States)

    Hawkins, A. T.; Johnson, S. E.

    2004-05-01

    Mount Desert Island, Maine, comprises a shallow level, Siluro-Devonian igneous complex surrounded by a distinctive breccia zone ("shatter zone" of Gilman and Chapman, 1988). The zone is very well exposed on the southern and eastern shores of the island and provides a unique opportunity to examine subvolcanic processes. The breccia of the Shatter Zone shows wide variation in percent matrix and clast, and may represent a spatial and temporal gradient in breccia formation due to a single eruptive or other catastrophic volcanic event. The shatter zone was divided into five developmental stages based on the extent of brecciation: Bar Harbor Formation, Sols Cliffs breccia, Seeley Road breccia, Dubois breccia, and Great Head breccia. A digital camera was employed to capture scale images of representative outcrops using a 0.5 m square Plexiglas frame. Individual images were joined in Adobe Photoshop to create a composite image of each outcrop. The composite photo was then exported to Adobe Illustrator, which was used to outline the clasts and produce a digital map of the outcrop for analysis. The fractal dimension (Fd) of each clast was calculated using NIH Image and a Euclidean distance mapping method described by Bérubé and Jébrak (1999) to quantify the morphology of the fragments, or the complexity of the outline. The more complex the fragment outline, the higher the fractal dimension, indicating that the fragment is less "mature" or has had less exposure to erosional processes, such as the injection of an igneous matrix. Sols Cliffs breccia has an average Fd of 1.125, whereas Great Head breccia has an average Fd of 1.040, with the stages between having intermediate values. The more complex clasts of the Sols Cliffs breccia with a small amount (26.38%) of matrix material suggests that it is the first stage in a sequence of brecciation ending at the more mature, matrix-supported (71.37%) breccia of Great Head. The results of this study will be used to guide isotopic

  2. 76 FR 27173 - Carolina Coastal Railway, Inc.-Acquisition and Operation Exemption-Rocky Mount & Western Railroad...

    Science.gov (United States)

    2011-05-10

    ... DEPARTMENT OF TRANSPORTATION Surface Transportation Board [Docket No. FD 35501] Carolina Coastal Railway, Inc.--Acquisition and Operation Exemption--Rocky Mount & Western Railroad Co., Inc. d/b/a Nash County Railroad Carolina Coastal Railway, Inc. (CLNA), a Class III rail carrier, has filed a verified...

  3. Peripheral facial weakness (Bell's palsy).

    Science.gov (United States)

    Basić-Kes, Vanja; Dobrota, Vesna Dermanović; Cesarik, Marijan; Matovina, Lucija Zadro; Madzar, Zrinko; Zavoreo, Iris; Demarin, Vida

    2013-06-01

    Peripheral facial weakness is a facial nerve damage that results in muscle weakness on one side of the face. It may be idiopathic (Bell's palsy) or may have a detectable cause. Almost 80% of peripheral facial weakness cases are primary and the rest of them are secondary. The most frequent causes of secondary peripheral facial weakness are systemic viral infections, trauma, surgery, diabetes, local infections, tumor, immune disorders, drugs, degenerative diseases of the central nervous system, etc. The diagnosis relies upon the presence of typical signs and symptoms, blood chemistry tests, cerebrospinal fluid investigations, nerve conduction studies and neuroimaging methods (cerebral MRI, x-ray of the skull and mastoid). Treatment of secondary peripheral facial weakness is based on therapy for the underlying disorder, unlike the treatment of Bell's palsy that is controversial due to the lack of large, randomized, controlled, prospective studies. There are some indications that steroids or antiviral agents are beneficial but there are also studies that show no beneficial effect. Additional treatments include eye protection, physiotherapy, acupuncture, botulinum toxin, or surgery. Bell's palsy has a benign prognosis with complete recovery in about 80% of patients, 15% experience some mode of permanent nerve damage and severe consequences remain in 5% of patients.

  4. MEGACARYOCYTES IN THE PERIPHERAL CIRCULATION

    Science.gov (United States)

    Minot, George R.

    1922-01-01

    A megacaryocyte is seen commonly as an occasional cell in the peripheral blood of patients with myelogenous leucemia. Less commonly they appear in relatively large numbers. These giant cells also may occur in the blood under other conditions. Their presence is indicative of a bone marrow under intense strain. PMID:19868650

  5. [Ultrasound-guided peripheral catheterization].

    Science.gov (United States)

    Salleras-Duran, Laia; Fuentes-Pumarola, Concepció

    2016-01-01

    Peripheral catheterization is a technique that can be difficult in some patients. Some studies have recently described the use of ultrasound to guide the venous catheterization. To describe the success rate, time required, complications of ultrasound-guided peripheral venous catheterization. and patients and professionals satisfaction The search was performed in databases (Medline-PubMed, Cochrane Library, CINAHL and Cuiden Plus) for studies published about ultrasound-guided peripheral venous catheterization performed on patients that provided results on the success of the technique, complications, time used, patient satisfaction and the type of professional who performed the technique. A total of 21 studies were included. Most of them get a higher success rate 80% in the catheterization ecoguide and time it is not higher than the traditional technique. The Technical complications analyzed were arterial puncture rates and lower nerve 10%. In all studies measuring and comparing patient satisfaction in the art ecoguide is greater. Various professional groups perform the technique. The use of ultrasound for peripheral pipes has a high success rate, complications are rare and the time used is similar to that of the traditional technique. The technique of inserting catheters through ultrasound may be learned by any professional group performing venipuncture. Finally, it gets underscores the high patient satisfaction with the use of this technique. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  6. Bias in Peripheral Depression Biomarkers

    DEFF Research Database (Denmark)

    Carvalho, André F; Köhler, Cristiano A; Brunoni, André R

    2016-01-01

    BACKGROUND: To aid in the differentiation of individuals with major depressive disorder (MDD) from healthy controls, numerous peripheral biomarkers have been proposed. To date, no comprehensive evaluation of the existence of bias favoring the publication of significant results or inflating effect...

  7. What Is Peripheral Artery Disease?

    Science.gov (United States)

    ... or bluish color to the skin A lower temperature in one leg compared to the other leg Poor nail growth on the toes and decreased hair growth on the legs Erectile dysfunction, especially among men who have diabetes Diagnosis Peripheral artery disease (P.A.D.) is diagnosed based ...

  8. Scaffolds for peripheral nerve repair and reconstruction.

    Science.gov (United States)

    Yi, Sheng; Xu, Lai; Gu, Xiaosong

    2018-06-02

    Trauma-associated peripheral nerve defect is a widespread clinical problem. Autologous nerve grafting, the current gold standard technique for the treatment of peripheral nerve injury, has many internal disadvantages. Emerging studies showed that tissue engineered nerve graft is an effective substitute to autologous nerves. Tissue engineered nerve graft is generally composed of neural scaffolds and incorporating cells and molecules. A variety of biomaterials have been used to construct neural scaffolds, the main component of tissue engineered nerve graft. Synthetic polymers (e.g. silicone, polyglycolic acid, and poly(lactic-co-glycolic acid)) and natural materials (e.g. chitosan, silk fibroin, and extracellular matrix components) are commonly used along or together to build neural scaffolds. Many other materials, including the extracellular matrix, glass fabrics, ceramics, and metallic materials, have also been used to construct neural scaffolds. These biomaterials are fabricated to create specific structures and surface features. Seeding supporting cells and/or incorporating neurotrophic factors to neural scaffolds further improve restoration effects. Preliminary studies demonstrate that clinical applications of these neural scaffolds achieve satisfactory functional recovery. Therefore, tissue engineered nerve graft provides a good alternative to autologous nerve graft and represents a promising frontier in neural tissue engineering. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Nerve growth factor-inducible large external (NILE) glycoprotein: studies of a central and peripheral neuronal marker.

    Science.gov (United States)

    Salton, S R; Richter-Landsberg, C; Greene, L A; Shelanski, M L

    1983-03-01

    The PC12 clone of pheochromocytoma cells undergoes neuronal differentiation in the presence of nerve growth factor (NGF). Concomitant with this is a significant induction in the incorporation of radiolabeled fucose or glucosamine into a 230,000-dalton cell surface glycoprotein named the NGF-Inducible Large External, or NILE, glycoprotein (GP) (McGuire, J. C., L. A. Greene, and A. V. Furano (1978) Cell 15: 357-365). In the current studies NILE GP was purified from PC12 cells using wheat germ agglutinin-agarose affinity chromatography and SDS-polyacrylamide gel electrophoresis (PAGE). Polyclonal antisera were raised against purified NILE GP and were found to selectively immunoprecipitate a single 230,000-dalton protein from detergent extracts of PC12 cells metabolically labeled with either [3H]fucose, [3H]glucosamine, or [35S]methionine. These antisera stained the surfaces of PC12 cells by indirect immunofluorescence and were cytotoxic to PC12 cells in the presence of complement. Limited treatment of PC12 cells with either trypsin or pronase produced a fucosylated 90,000-dalton immunoreactive fragment of NILE GP which remained in the membrane. Using quantitative immunoelectrophoresis, the action of NGF on NILE GP was represent an increase in the amount of protein, rather than a selective increase in carbohydrate incorporation. Immunofluorescent staining of primary cell cultures and tissue whole mounts revealed that immunologically cross-reactive NILE GP appears to be expressed on the cell surfaces (somas and neurites) of most if not all peripheral and central neurons examined. Immunoprecipitation of radiolabeled cultures showed that the cross-reactive material had an apparent molecular weight by SDS-PAGE of 225,000 to 230,000 in the peripheral nervous system and 200,000 to 210,000 in the central nervous system. NILE-cross-reactive material was also found to a small extent on Schwann cell surfaces, but not at all on a variety of other cell types. These results suggest

  10. Mechanical Design of an Omni-Directional Sensor Mount

    National Research Council Canada - National Science Library

    Rosheim, Mark

    2002-01-01

    This effort has been directed to development and demonstration of a gimbal mount capable of 180 degree singularity- free pitch and yaw motion about a two-axis center, avoiding the common problem of gimbal lock...

  11. Rapid mounting of adult Drosophila structures in Hoyer's medium.

    Science.gov (United States)

    Stern, David L; Sucena, Elio

    2012-01-01

    The Drosophila cuticle carries a rich array of morphological details. Thus, cuticle examination has had a central role in the history of genetics. This protocol describes a procedure for mounting adult cuticles in Hoyer's medium, a useful mountant for both larval and adult cuticles. The medium digests soft tissues rapidly, leaving the cuticle cleared for observation. In addition, samples can be transferred directly from water to Hoyer's medium. However, specimens mounted in Hoyer's medium degrade over time. For example, the fine denticles on the larval dorsum are best observed soon after mounting; they begin to fade after 1 week, and can disappear completely after several months. More robust features, such as the ventral denticle belts, will persist for a longer period of time. Because adults cannot profitably be mounted whole in Hoyer's medium, some dissection is necessary.

  12. Application of Evolutionary Computation in Automotive Powertrain Mount Tuning

    Directory of Open Access Journals (Sweden)

    Anab Akanda

    2006-01-01

    Full Text Available Engine mount tuning is a multi-disciplinary exercise since it affects Idle-shake, Road-shake and power-train noise response. Engine inertia is often used as a tuned absorber for controlling suspension resonance related road-shake issues. Last but not least, vehicle ride and handling may also be affected by mount tuning. In this work, Torque-Roll-Axis (TRA decoupling of the rigid powertrain was used as a starting point for mount tuning. Nodal point of flexible powertrain bending was used to define the envelop for transmission mount locations. The frequency corresponding to the decoupled roll mode of the rigid powertrain was then adjusted for idle-shake and road-shake response management.

  13. A vehicle mounted scintillation ratemeter for environmental survey

    International Nuclear Information System (INIS)

    Cavell, I.W.

    1960-01-01

    An improved method of mounting an existing environmental gamma survey equipment in a vehicle is described. Performance data for the equipment is given and some typical radiometric traces obtained at A.E.E. Winfrith given. (author)

  14. Low radioactivity material for use in mounting radiation detectors

    Science.gov (United States)

    Fong, Marshall; Metzger, Albert E.; Fox, Richard L.

    1988-01-01

    Two materials, sapphire and synthetic quartz, have been found for use in Ge detector mounting assemblies. These materials combine desirable mechanical, thermal, and electrical properties with the radioactive cleanliness required to detect minimal amounts of K, Th, and U.

  15. How Mount Stromlo Observatory shed its imperial beginnings

    Science.gov (United States)

    Bhathal, Ragbir

    2014-12-01

    In the 90 years since its foundation in 1924, Mount Stromlo Observatory in Australia has changed from an outpost of empire to an international research institution. Ragbir Bhathal examines how the British influence waxed and waned.

  16. Fathead minnow whole-mount in situ hybridization (WISH)

    Data.gov (United States)

    U.S. Environmental Protection Agency — This study demonstrates the potential of whole-mount in situ hybridization (WISH), in conjunction with quantitative real-time polymerase chain reaction (QPCR)...

  17. Optimization of a dual mode Rowland mount spectrometer used in the 120-950 nm wavelength range

    Science.gov (United States)

    McDowell, M. W.; Bouwer, H. K.

    In a recent article, several configurations were described whereby a Rowland mount spectrometer could be modified to cover a wavelength range of 120-950 nm. In one of these configurations, large additional image aberration is introduced which severely limits the spectral resolving power. In the present article, the theoretical imaging properties of this configuration are considered and a simple method is proposed to reduce this aberration. The optimized system possesses an image quality similar to the conventional Rowland mount with the image surface slightly displaced from the Rowland circle but concentric to it.

  18. Angioplasty and stent placement - peripheral arteries - discharge

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000234.htm Angioplasty and stent placement - peripheral arteries - discharge To use the sharing ... peripheral artery). You may have also had a stent placed. To perform the procedure: Your doctor inserted ...

  19. Hypothyroidism: Can It Cause Peripheral Neuropathy?

    Science.gov (United States)

    Hypothyroidism: Can it cause peripheral neuropathy? Can hypothyroidism cause peripheral neuropathy and, if so, how is it treated? Answers from Todd B. Nippoldt, M.D. Hypothyroidism — a condition in which your ...

  20. Taking Charge: Walter Sydney Adams and the Mount Wilson Observatory

    Science.gov (United States)

    Brashear, R.

    2004-12-01

    The growing preeminence of American observational astronomy in the first half of the 20th century is a well-known story and much credit is given to George Ellery Hale and his skill as an observatory-building entrepreneur. But a key figure who has yet to be discussed in great detail is Walter Sydney Adams (1876-1956), Hale's Assistant Director at Mount Wilson Observatory. Due to Hale's illnesses, Adams was Acting Director for much of Hale's tenure, and he became the second Director of Mount Wilson from 1923 to 1946. Behind his New England reserve Adams was instrumental in the growth of Mount Wilson and thus American astronomy in general. Adams was hand-picked by Hale to take charge of stellar spectroscopy work at Yerkes and Mount Wilson and the younger astronomer showed tremendous loyalty to Hale and Hale's vision throughout his career. As Adams assumed the leadership role at Mount Wilson he concentrated on making the observatory a place where researchers worked with great freedom but maintain a high level of cooperation. This paper will concentrate on Adams's early years and look at his growing relationship with Hale and how he came to be the central figure in the early history of Mount Wilson as both a solar and stellar observatory. His education, his years at Dartmouth and Yerkes (including his unfortunate encounter with epsilon Leonis), and his formative years on Mount Wilson are all important in learning how he shaped the direction of Mount Wilson and the development of American astronomy in the first half of the 20th century. This latter history cannot be complete until we bring Adams into better focus.

  1. Some technical solutions on organization and technology of reactor room component mounting

    International Nuclear Information System (INIS)

    Romanovskij, V.I.

    1982-01-01

    Design of the production equipment for mounting sites of heat facilities of the Zaporozhe NPP is considered. Plan of the production equipment for mounting sites of heat facilities and flowsheet of mounting of supporting truss of the reactor are presented

  2. National Ingition Facility subsystem design requirements optical mounts SSDR 1.4.4

    International Nuclear Information System (INIS)

    Richardson, M.

    1996-01-01

    This SSDR establishes the performance, design, development and test requirements for NIF Beam Transport Optomechanical Subsystems. optomechanical Subsystems includes the mounts for the beam transport mirrors, LMl - LM8, the polarizer mount, and the spatial filter lens mounts

  3. New active machine tool drive mounting on the frame

    Directory of Open Access Journals (Sweden)

    Švéda J.

    2007-10-01

    Full Text Available The paper deals with the new active mounting of the machine tool drives. The commonly used machine tools are at this time mainly equipped with fix-mounting of the feed drives. This structure causes full transmission of the force shocks to the machine bed and thereby restricts the dynamic properties of the motion axis and the whole machine. The spring-mounting of the feed drives is one of the possibilities how to partially suppress the vibrations. The force that reacts to the machine tool bed is transformed thereby the vibrations are lightly reduced. Unfortunately the transformation is not fully controlled. The new active mounting of the machine tool drives allows to fully control the force behaviour that react to the machine body. Thereby the number of excited frequencies on the machine tool bed is significantly reduced. The active variant of the feed drive mounting is characterized by the synergistic cooperation between two series-connected actuators (“motor on motor”. The paper briefly describes design, control techniques and optimization of the feed drives with the new active mounting conception.

  4. Coaching Peripheral Vision Training for Soccer Athletes

    Science.gov (United States)

    Marques, Nelson Kautzner, Jr.

    2010-01-01

    Brazilian Soccer began developing its current emphasis on peripheral vision in the late 1950s, by initiative of coach of the Canto do Rio Football Club, in Niteroi, Rio de Janeiro, a pioneer in the development of peripheral vision training in soccer players. Peripheral vision training gained world relevance when a young talent from Canto do Rio,…

  5. Peripheral Neuropathy – Clinical and Electrophysiological Considerations

    Science.gov (United States)

    Chung, Tae; Prasad, Kalpana; Lloyd, Thomas E.

    2013-01-01

    This article is a primer on the pathophysiology and clinical evaluation of peripheral neuropathy for the radiologist. Magnetic resonance neurography (MRN) has utility in the diagnosis of many focal peripheral nerve lesions. When combined with history, examination, electrophysiology, and laboratory data, future advancements in high-field MRN may play an increasingly important role in the evaluation of patients with peripheral neuropathy. PMID:24210312

  6. Peripheral mowing blade. Final report ending 08/24/00

    Energy Technology Data Exchange (ETDEWEB)

    Darden, John A.

    2000-08-24

    The first prototype built for the peripheral mower blade was the nineteen foot batwing mower. It features twelve-inch blades, three-sixteenth thick. The configuration of the mower is three individual rotor gangs housed in separate housing all mounted to a centrally located housing. Each outer gang is driven by power being diverted through the center rotor. The power is supplied to each wing through means of a disconnect mechanism which allows the outer gangs to stop in the event that particular housing is raised by hydraulic power. This unit has given us unlimited information in the drive and power applications needed to drive the peripheral blade gangs. The nineteen foot unit has not changed much from the beginning, but information received from its performance has been applied to the building of a preproduction unit that is now in progress. Another prototype unit we have work with is the seven foot mounted mower. This unit consisted of a standard ASAE category I three-point hitch. The hitch was made by using an "A" frame which formed the attaching points for the mower and two back straps that gives support to the hitch assembly. The deck allowed for one-inch blade clearance at the top and featured a slanted deck extension at both the front and rear. The extension were formed by means of two breaks that run parallel to the blade gang and angled down at one hundred thirty degrees at the front and one hundred fifteen degrees at the rear. A roller is mounted across the back of the deck. This roller offers support to the deck while on the ground and is adjustable for height of cut control. This unit was made with a small roller, and too lighter hitch. After only a few hours of test proved that both items would have to be beefed up. The rear roller was increased to a four-inch diameter. The hitch was changed to a two-sided solid metal hitch three-eighths of an inch thick on the next machines.

  7. Monitoring sweep in peripheral waterflood

    International Nuclear Information System (INIS)

    Rouser, B.J.; Al-Askar, Y.A.; Hassoun, T.H.

    1991-01-01

    This paper examines the techniques used and the results obtained in monitoring the water advance in a peripheral waterflood of a carbonate reservoir. The peripheral pattern used in the subject reservoir gives a water advanced similar to that obtained in a water drive reservoir. However, monitoring this particular reservoir is complicated by the use of a low salinity brine for flooding and the areal shape of the reservoir. The use of pulsed neutron capture logging in conjunction with production logging has been effective in differentiating between oil and water in porous zones in existing producers. The use of the two logs has been successful despite the problems normally encountered when logging open hole completions in a reservoir being flooded with a low salinity brine. Results have been confirmed and enhanced by open hole logs of new wells being drilled in the water invaded areas

  8. Peripheral nerve conduits: technology update

    Directory of Open Access Journals (Sweden)

    Arslantunali D

    2014-12-01

    Full Text Available D Arslantunali,1–3,* T Dursun,1,2,* D Yucel,1,4,5 N Hasirci,1,2,6 V Hasirci,1,2,7 1BIOMATEN, Center of Excellence in Biomaterials and Tissue Engineering, Middle East Technical University (METU, Ankara, Turkey; 2Department of Biotechnology, METU, Ankara, Turkey; 3Department of Bioengineering, Gumushane University, Gumushane, Turkey; 4Faculty of Engineering, Department of Medical Engineering, Acibadem University, Istanbul, Turkey; 5School of Medicine, Department of Histology and Embryology, Acibadem University, Istanbul, Turkey; 6Department of Chemistry, Faculty of Arts and Sciences, METU, Ankara, Turkey; 7Department of Biological Sciences, Faculty of Arts and Sciences, METU, Ankara, Turkey *These authors have contributed equally to this work Abstract: Peripheral nerve injury is a worldwide clinical problem which could lead to loss of neuronal communication along sensory and motor nerves between the central nervous system (CNS and the peripheral organs and impairs the quality of life of a patient. The primary requirement for the treatment of complete lesions is a tension-free, end-to-end repair. When end-to-end repair is not possible, peripheral nerve grafts or nerve conduits are used. The limited availability of autografts, and drawbacks of the allografts and xenografts like immunological reactions, forced the researchers to investigate and develop alternative approaches, mainly nerve conduits. In this review, recent information on the various types of conduit materials (made of biological and synthetic polymers and designs (tubular, fibrous, and matrix type are being presented. Keywords: peripheral nerve injury, natural biomaterials, synthetic biomaterials

  9. Large Extremity Peripheral Nerve Repair

    Science.gov (United States)

    2016-12-01

    LM, de Crombrugghe B. Some recent advances in the chemistry and biology of trans- forming growth factor-beta. J Cell Biol 1987;105:1039e45. 12. Hao Y...SUPPLEMENTARY NOTES 14. ABSTRACT In current war trauma, 20-30% of all extremity injuries and >80% of penetrating injuries being associated with peripheral nerve...through both axonal advance and in revascularization of the graft following placement. We are confident that this technology may allow us to

  10. Communication, Consumption and Peripheral Politics

    Directory of Open Access Journals (Sweden)

    NÍZIA VILLAÇA

    2009-02-01

    Full Text Available This essay analyses central/peripheral dynamics and its new semantics in the big scenario of globalization. The processes of hybridization between the local and the global spaces are discussed focusing the strategies of inclusion and exclusion through some examples from media and cultural industry. The methodology helps to reflect about the theme using elements of epistemology communication, consumer society and cultural studies.

  11. Peripheral facial palsy in children.

    Science.gov (United States)

    Yılmaz, Unsal; Cubukçu, Duygu; Yılmaz, Tuba Sevim; Akıncı, Gülçin; Ozcan, Muazzez; Güzel, Orkide

    2014-11-01

    The aim of this study is to evaluate the types and clinical characteristics of peripheral facial palsy in children. The hospital charts of children diagnosed with peripheral facial palsy were reviewed retrospectively. A total of 81 children (42 female and 39 male) with a mean age of 9.2 ± 4.3 years were included in the study. Causes of facial palsy were 65 (80.2%) idiopathic (Bell palsy) facial palsy, 9 (11.1%) otitis media/mastoiditis, and tumor, trauma, congenital facial palsy, chickenpox, Melkersson-Rosenthal syndrome, enlarged lymph nodes, and familial Mediterranean fever (each 1; 1.2%). Five (6.1%) patients had recurrent attacks. In patients with Bell palsy, female/male and right/left ratios were 36/29 and 35/30, respectively. Of them, 31 (47.7%) had a history of preceding infection. The overall rate of complete recovery was 98.4%. A wide variety of disorders can present with peripheral facial palsy in children. Therefore, careful investigation and differential diagnosis is essential. © The Author(s) 2013.

  12. Peripheral tumors alter neuroinflammatory responses to lipopolysaccharide in female rats.

    Science.gov (United States)

    Pyter, Leah M; El Mouatassim Bih, Sarah; Sattar, Husain; Prendergast, Brian J

    2014-03-13

    Cancer is associated with an increased prevalence of depression. Peripheral tumors induce inflammatory cytokine production in the brain and depressive-like behaviors. Mounting evidence indicates that cytokines are part of a pathway by which peripheral inflammation causes depression. Neuroinflammatory responses to immune challenges can be exacerbated (primed) by prior immunological activation associated with aging, early-life infection, and drug exposure. This experiment tested the hypothesis that peripheral tumors likewise induce neuroinflammatory sensitization or priming. Female rats with chemically-induced mammary carcinomas were injected with either saline or lipopolysaccharide (LPS, 250μg/kg; i.p.), and expression of mRNAs involved in the pathway linking inflammation and depression (interleukin-1beta [Il-1β], CD11b, IκBα, indolamine 2,3-deoxygenase [Ido]) was quantified by qPCR in the hippocampus, hypothalamus, and frontal cortex, 4 or 24h post-treatment. In the absence of LPS, hippocampal Il-1β and CD11b mRNA expression were elevated in tumor-bearing rats, whereas Ido expression was reduced. Moreover, in saline-treated rats basal hypothalamic Il-1β and CD11b expression were positively correlated with tumor weight; heavier tumors, in turn, were characterized by more inflammatory, necrotic, and granulation tissue. Tumors exacerbated CNS proinflammatory gene expression in response to LPS: CD11b was greater in hippocampus and frontal cortex of tumor-bearing relative to tumor-free rats, IκBα was greater in hippocampus, and Ido was greater in hypothalamus. Greater neuroinflammatory responses in tumor-bearing rats were accompanied by attenuated body weight gain post-LPS. The data indicate that neuroinflammatory pathways are potentiated, or primed, in tumor-bearing rats, which may exacerbate future negative behavioral consequences. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. UHV mirror mounts for photophysics beamline at Indus-I

    International Nuclear Information System (INIS)

    Meenakshi Raja Rao, P.; Bhattacharya, S.S.; Das, N.C.; Rajasekhar, B.N.; Roy, A.P.

    1995-01-01

    Photophysics beamline makes use of a combination of two toroidal mirrors and one meter Seya-Namioka Monochromator in its fore optics. The fore optics monochromatises and steers the synchrotron radiation source (SRS) beam from its tangent point to the sample situated at a distance of about five meters. Slit widths of the monochromator are of the order of 100μ and the sample size is one mm 2 . Hence it is essential to impart precision rotational and translational movements of the same order of magnitude to the mirrors with the use of appropriate mirror mounts. Since Indus-1 operates at a pressure -9 mbar, the mirror mounts should be UHV compatible and the movements should be actuated under UHV. The mirrors along with the mirror mounts are enclosed in UHV chambers. The mirror chambers have been fabricated at Centre for Advanced Technology (CAT) workshops and tested up to a pressure of 10 -9 mbar. The mirror mounts are designed, fabricated and leak checked (He leak rate -10 std cc/s) The precision movements are achieved with the help of bellow sealed shaft mechanism and adjustable screws provided with the kinematic mount of the mirror frame. The performance of the mirror mount was tested at atmospheric pressure by using a laser beam and found to be good. The minimum displacement of the laser beam at slit and sample positions is ∼ 70μ which is quite adequate for optical alignment. The performance of the mirror mount under UHV conditions is being evaluated. (author). 4 refs., 3 figs

  14. Development and evaluation of a boat-mounted RFID antenna for monitoring freshwater mussels

    Science.gov (United States)

    Fischer, Jesse R.; Neebling, Travis E.; Quist, Michael C.

    2012-01-01

    Development of radio frequency identification (RFID) technology and passive integrated transponder (PIT) tags has substantially increased the ability of researchers and managers to monitor populations of aquatic organisms. However, use of transportable RFID antenna systems (i.e., backpack-mounted) is currently limited to wadeable aquatic environments (RFID antenna to detect individually PIT-tagged benthic aquatic organisms (mussels). We evaluated the effects of tag orientation on detection distances in water with a 32-mm half-duplex PIT tag. Detection distances up to 50 cm from the antenna coils were obtained, but detection distance was dependent on tag orientation. We also evaluated detection distance of PIT tags beneath the sediment to simulate detection of burrowing mussels with 23- and 32-mm tags. In sand substrate, the maximum detection distance varied from 3.5 cm and 4.5 cm (vertical tag orientation) to 24.7 cm and 39.4 cm (45° tag orientation) for the 23- and 32-mm PIT tags, respectively. Our results suggest a 1.4-m total detection width for tagged mussels on the substrate surface by the boat-mounted antenna system regardless of tag orientation. However, burrowed mussels may require multiple passes to increase detection that would be influenced by depth, tag orientation, and tag size. Construction of the boat-mounted antenna was relatively low in cost (<500 USD) and had several advantages (less labor and time intensive, increased safety) over traditional mussel sampling techniques (diving, snorkeling) in nonwadeable habitats.

  15. Shallow repeating seismic events under an alpine glacier at Mount Rainier, Washington, USA

    Science.gov (United States)

    Thelen, Weston A.; Allstadt, Kate E.; De Angelis, Silvio; Malone, Stephen D.; Moran, Seth C.; Vidale, John

    2013-01-01

    We observed several swarms of repeating low-frequency (1–5 Hz) seismic events during a 3 week period in May–June 2010, near the summit of Mount Rainier, Washington, USA, that likely were a result of stick–slip motion at the base of alpine glaciers. The dominant set of repeating events ('multiplets') featured >4000 individual events and did not exhibit daytime variations in recurrence interval or amplitude. Volcanoes and glaciers around the world are known to produce seismic signals with great variability in both frequency content and size. The low-frequency character and periodic recurrence of the Mount Rainier multiplets mimic long-period seismicity often seen at volcanoes, particularly during periods of unrest. However, their near-surface location, lack of common spectral peaks across the recording network, rapid attenuation of amplitudes with distance, and temporal correlation with weather systems all indicate that ice-related source mechanisms are the most likely explanation. We interpret the low-frequency character of these multiplets to be the result of trapping of seismic energy under glacial ice as it propagates through the highly heterogeneous and attenuating volcanic material. The Mount Rainier multiplet sequences underscore the difficulties in differentiating low-frequency signals due to glacial processes from those caused by volcanic processes on glacier-clad volcanoes.

  16. Peripheral doses from pediatric IMRT

    International Nuclear Information System (INIS)

    Klein, Eric E.; Maserang, Beth; Wood, Roy; Mansur, David

    2006-01-01

    Peripheral dose (PD) data exist for conventional fields (≥10 cm) and intensity-modulated radiotherapy (IMRT) delivery to standard adult-sized phantoms. Pediatric peripheral dose reports are limited to conventional therapy and are model based. Our goal was to ascertain whether data acquired from full phantom studies and/or pediatric models, with IMRT treatment times, could predict Organ at Risk (OAR) dose for pediatric IMRT. As monitor units (MUs) are greater for IMRT, it is expected IMRT PD will be higher; potentially compounded by decreased patient size (absorption). Baseline slab phantom peripheral dose measurements were conducted for very small field sizes (from 2 to 10 cm). Data were collected at distances ranging from 5 to 72 cm away from the field edges. Collimation was either with the collimating jaws or the multileaf collimator (MLC) oriented either perpendicular or along the peripheral dose measurement plane. For the clinical tests, five patients with intracranial or base of skull lesions were chosen. IMRT and conventional three-dimensional (3D) plans for the same patient/target/dose (180 cGy), were optimized without limitation to the number of fields or wedge use. Six MV, 120-leaf MLC Varian axial beams were used. A phantom mimicking a 3-year-old was configured per Center for Disease Control data. Micro (0.125 cc) and cylindrical (0.6 cc) ionization chambers were appropriated for the thyroid, breast, ovaries, and testes. The PD was recorded by electrometers set to the 10 -10 scale. Each system set was uniquely calibrated. For the slab phantom studies, close peripheral points were found to have a higher dose for low energy and larger field size and when MLC was not deployed. For points more distant from the field edge, the PD was higher for high-energy beams. MLC orientation was found to be inconsequential for the small fields tested. The thyroid dose was lower for IMRT delivery than that predicted for conventional (ratio of IMRT/cnventional ranged from

  17. The surgery of peripheral nerves (including tumors)

    DEFF Research Database (Denmark)

    Fugleholm, Kåre

    2013-01-01

    Surgical pathology of the peripheral nervous system includes traumatic injury, entrapment syndromes, and tumors. The recent significant advances in the understanding of the pathophysiology and cellular biology of peripheral nerve degeneration and regeneration has yet to be translated into improved...... surgical techniques and better outcome after peripheral nerve injury. Decision making in peripheral nerve surgery continues to be a complex challenge, where the mechanism of injury, repeated clinical evaluation, neuroradiological and neurophysiological examination, and detailed knowledge of the peripheral...... nervous system response to injury are prerequisite to obtain the best possible outcome. Surgery continues to be the primary treatment modality for peripheral nerve tumors and advances in adjuvant oncological treatment has improved outcome after malignant peripheral nerve tumors. The present chapter...

  18. Hepatic abscess versus peripheral cholangiocarcinoma: Sonographic differentiation

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hwan Hoon; Kim, Yun Hwan; Kang, Chang Ho; Chung, Kyoo Byung; Suh, Won Hyuck [Korea University College of Medicine, Seoul (Korea, Republic of); Lee, Chang Hee [Kunkuk University College of Medicine, Chung-Ju Hospital, Chung-Ju (Korea, Republic of)

    2000-12-15

    To find out the sonographic findings that are useful to differentiate hepatic abscess from peripheral cholangiocarcinoma. Twenty-two hepatic abscesses and 22 peripheral cholangiocarcinomas which had been confirmed histologically were included in this study. Objective points were echo characteristics of the lesion, internal septation, presence of peripheral low echoic rim, demarcation from normal liver(well or poorly defined), posterior enhancement, multiplicity, dilatation of bile duct(obstructive or non-obstructive), intrahepatic duct stone, pleural effusion, and intra-abdominal fluid collection. Echo characteristics of the lesion were classified in-to four types. Type I; Predominantly echogenic with hypoechoic portion, type II; Echogenic without hypoechoic portion, type III; Predominantly hypoechoic with echogenic portion, type IV; Hypoechoic without echogenic portion. 1)Nine abscesses and 2 peripheral cholangiocarcinomas were type I(p=0.037), 2)One abscess and 18 peripheral cholangiocarcinomas were type II(p=0.001), 3)Seven abscesses and none of peripheral cholangiocarcinomas were type III(p=0.001), 4)Five abscesses and 2 peripheral cholangiocarcinomas were type IV(p=0.410). Only 7 abscesses showed internal septations(p=0.013). One abscess and 9 peripheral cholangiocarcinomas showed peripheral hypoechoic halos(p=0.012). Only 9 peripheral cholangiocarcinomas showed obstructive bile duct dilatation (p=0.001). There were no statistically significant differences between abscess and peripheral cholangiocarcinoma on other objective points. Predominantly echogenic with hypoechoic portion, predominantly hypoechoic with echogenic portion, and internal septation are the features suggestive of hepatic abscess, and echogenic without hypoechoic portion, peripheral hypoechoic halo, obstructive bile duct dilatation are suggestive of peripheral cholangiocarcinoma. Therefore these sonographic findings are helpful to differentiate hepatic abscess from peripheral

  19. Piezoresistive Carbon-based Hybrid Sensor for Body-Mounted Biomedical Applications

    Science.gov (United States)

    Melnykowycz, M.; Tschudin, M.; Clemens, F.

    2017-02-01

    For body-mounted sensor applications, the evolution of soft condensed matter sensor (SCMS) materials offer conformability andit enables mechanical compliance between the body surface and the sensing mechanism. A piezoresistive hybrid sensor and compliant meta-material sub-structure provided a way to engineer sensor physical designs through modification of the mechanical properties of the compliant design. A piezoresistive fiber sensor was produced by combining a thermoplastic elastomer (TPE) matrix with Carbon Black (CB) particles in 1:1 mass ratio. Feedstock was extruded in monofilament fiber form (diameter of 300 microns), resulting in a highly stretchable sensor (strain sensor range up to 100%) with linear resistance signal response. The soft condensed matter sensor was integrated into a hybrid design including a 3D printed metamaterial structure combined with a soft silicone. An auxetic unit cell was chosen (with negative Poisson’s Ratio) in the design in order to combine with the soft silicon, which exhibits a high Poisson’s Ratio. The hybrid sensor design was subjected to mechanical tensile testing up to 50% strain (with gauge factor calculation for sensor performance), and then utilized for strain-based sensing applications on the body including gesture recognition and vital function monitoring including blood pulse-wave and breath monitoring. A 10 gesture Natural User Interface (NUI) test protocol was utilized to show the effectiveness of a single wrist-mounted sensor to identify discrete gestures including finger and hand motions. These hand motions were chosen specifically for Human Computer Interaction (HCI) applications. The blood pulse-wave signal was monitored with the hand at rest, in a wrist-mounted. In addition different breathing patterns were investigated, including normal breathing and coughing, using a belt and chest-mounted configuration.

  20. Mounting ground sections of teeth: Cyanoacrylate adhesive versus Canada balsam.

    Science.gov (United States)

    Vangala, Manogna Rl; Rudraraju, Amrutha; Subramanyam, R V

    2016-01-01

    Hard tissues can be studied by either decalcification or by preparing ground sections. Various mounting media have been tried and used for ground sections of teeth. However, there are very few studies on the use of cyanoacrylate adhesive as a mounting medium. The aim of our study was to evaluate the efficacy of cyanoacrylate adhesive (Fevikwik™) as a mounting medium for ground sections of teeth and to compare these ground sections with those mounted with Canada balsam. Ground sections were prepared from twenty extracted teeth. Each section was divided into two halves and mounted on one slide, one with cyanoacrylate adhesive (Fevikwik™) and the other with Canada balsam. Scoring for various features in the ground sections was done by two independent observers. Statistical analysis using Student's t-test (unpaired) of average scores was performed for each feature observed. No statistically significant difference was found between the two for most of the features. However, cyanoacrylate was found to be better than Canada balsam for observing striae of Retzius (P < 0.0205), enamel lamellae (P < 0.036), dentinal tubules (P < 0.0057), interglobular dentin (P < 0.0001), sclerotic dentin - transmitted light (P < 0.00001), sclerotic dentin - polarized light (P < 0.0002) and Sharpey's fibers (P < 0.0004). This initial study shows that cyanoacrylate is better than Canada balsam for observing certain features of ground sections of teeth. However, it remains to be seen whether it will be useful for studying undecalcified sections of carious teeth and for soft tissue sections.

  1. Mirror boxes and mirror mounts for photophysics beamline

    International Nuclear Information System (INIS)

    Raja Rao, P.M.; Raja Sekhar, B.N.; Das, N.C.; Khan, H.A.; Bhattacharya, S.S.; Roy, A.P.

    1996-01-01

    Photophysics beamline makes use of one metre Seya-Namioka monochromator and two toroidal mirrors in its fore optics. The first toroidal mirror (pre mirror) focuses light originating from the tangent point of the storage ring onto the entrance slit of the monochromator and second toroidal mirror (post mirror) collects light from the exit slit of the monochromator and focuses light onto the sample placed at a distance of about one metre away from the 2nd mirror. To steer light through monochromator and to focus it on the sample of 1mm x 1mm size require precision rotational and translational motion of the mirrors and this has been achieved with the help of precision mirror mounts. Since Indus-1 operates at pressures less than 10 -9 m.bar, the mirror mounts should be manipulated under similar ultra high vacuum conditions. Considering these requirements, two mirror boxes and two mirror mounts have been designed and fabricated. The coarse movements to the mirrors are imparted from outside the mirror chamber with the help of x-y tables and precision movements to the mirrors are achieved with the help of mirror mounts. The UHV compatibility and performance of the mirror mounts connected to mirror boxes under ultra high vacuum condition is evaluated. The details of the design, fabrication and performance evaluation are discussed in this report. 5 refs., 9 figs., 1 tab

  2. Multi-Mounted X-Ray Computed Tomography.

    Science.gov (United States)

    Fu, Jian; Liu, Zhenzhong; Wang, Jingzheng

    2016-01-01

    Most existing X-ray computed tomography (CT) techniques work in single-mounted mode and need to scan the inspected objects one by one. It is time-consuming and not acceptable for the inspection in a large scale. In this paper, we report a multi-mounted CT method and its first engineering implementation. It consists of a multi-mounted scanning geometry and the corresponding algebraic iterative reconstruction algorithm. This approach permits the CT rotation scanning of multiple objects simultaneously without the increase of penetration thickness and the signal crosstalk. Compared with the conventional single-mounted methods, it has the potential to improve the imaging efficiency and suppress the artifacts from the beam hardening and the scatter. This work comprises a numerical study of the method and its experimental verification using a dataset measured with a developed multi-mounted X-ray CT prototype system. We believe that this technique is of particular interest for pushing the engineering applications of X-ray CT.

  3. Eruption prediction aided by electronic tiltmeter data at mount st. Helens.

    Science.gov (United States)

    Dzurisin, D; Westphal, J A; Johnson, D J

    1983-09-30

    Telemetry from electronic tiltmeters in the crater at Mount St. Helens contributed to accurate predictions of all six effusive eruptions from June 1981 to August 1982. Tilting of the crater floor began several weeks before each eruption, accelerated sharply for several days, and then abruptly changed direction a few minutes to days before extrusion began. Each episode of uplift was caused by the intrusion of magma into the lava dome from a shallow source, causing the dome to inflate and eventually rupture. Release of magma pressure and increased surface loading by magma added to the dome combined to cause subsidence just prior to extrusion.

  4. Monitoring of roof mounted photovoltaics at the ECOS Millenium Environmental Centre

    Energy Technology Data Exchange (ETDEWEB)

    Smyth, M.; Mondol, J.D.

    2004-07-01

    A three-year study in which 103 square metres of photovoltaics mounted on a roof at the ECOS Millenium Environmental Centre in N. Ireland were monitored by the University of Ulster for energy delivery and degradation is described. Concomitantly, software written to simulate the behaviour of the photovoltaics was appraised. Factors monitored were: insolation; ambient temperature; wind speed and direction; module surface temperatures; output voltage; current and power; and load voltage and power. The work was part of the DTI New and Renewable Energy Programme and managed by Future Energy Solutions. The monitoring formally ended in December 2003 but it was expected that monitoring would continue beyond that date.

  5. Melting experiment on concrete waste using a hollow type plasma torch mounted on furnace

    International Nuclear Information System (INIS)

    Moon, Y. P.; Kim, T. W.; Kim, H. S.; Shin, S. U.; Lee, M. C.

    2000-01-01

    A furnace coupled with a hollow type plasma torch was manufactured and installed in order to develop a volume reduction technology for non-combustible radioactive waste using plasma. A melting test with 10kg of concrete waste was carried out for the evaluation of melting characteristics in the non-transferred operation mode for 20 minutes with the melter. Feeded concrete was completely melted. However, the molten bath was not easily discharged because of its high viscosity. It was found that some molten slag spat from the molten bath was coated on the surface of torch which was mounted vertically inside furnace

  6. Peripheral Mechanisms of Ischemic Myalgia

    Directory of Open Access Journals (Sweden)

    Luis F. Queme

    2017-12-01

    Full Text Available Musculoskeletal pain due to ischemia is present in a variety of clinical conditions including peripheral vascular disease (PVD, sickle cell disease (SCD, complex regional pain syndrome (CRPS, and even fibromyalgia (FM. The clinical features associated with deep tissue ischemia are unique because although the subjective description of pain is common to other forms of myalgia, patients with ischemic muscle pain often respond poorly to conventional analgesic therapies. Moreover, these patients also display increased cardiovascular responses to muscle contraction, which often leads to exercise intolerance or exacerbation of underlying cardiovascular conditions. This suggests that the mechanisms of myalgia development and the role of altered cardiovascular function under conditions of ischemia may be distinct compared to other injuries/diseases of the muscles. It is widely accepted that group III and IV muscle afferents play an important role in the development of pain due to ischemia. These same muscle afferents also form the sensory component of the exercise pressor reflex (EPR, which is the increase in heart rate and blood pressure (BP experienced after muscle contraction. Studies suggest that afferent sensitization after ischemia depends on interactions between purinergic (P2X and P2Y receptors, transient receptor potential (TRP channels, and acid sensing ion channels (ASICs in individual populations of peripheral sensory neurons. Specific alterations in primary afferent function through these receptor mechanisms correlate with increased pain related behaviors and altered EPRs. Recent evidence suggests that factors within the muscles during ischemic conditions including upregulation of growth factors and cytokines, and microvascular changes may be linked to the overexpression of these different receptor molecules in the dorsal root ganglia (DRG that in turn modulate pain and sympathetic reflexes. In this review article, we will discuss the

  7. Hybrid diffractive-refractive optical system design of head-mounted display for augmented reality

    Science.gov (United States)

    Zhang, Huijuan

    2005-02-01

    An optical see-through head-mounted display for augmented reality is designed in this paper. Considering the factors, such as the optical performance, the utilization ratios of energy of real world and virtual world, the feelings of users when he wears it and etc., a structure of the optical see-through is adopted. With the characteristics of the particular negative dispersive and the power of realizing random-phase modulation, the diffractive surface is helpful for optical system of reducing weight, simplifying structure and etc., and a diffractive surface is introduced in our optical system. The optical system with 25 mm eye relief, 12 mm exit pupil and 20° (H)x15.4° (V) field-of-view is designed. The utilization ratios of energy of real world and virtual world are 1/4 and 1/2, respectively. The angular resolution of display is 0.27 mrad and it less than that of the minimum of human eyes. The diameter of this system is less than 46mm, and it applies the binocular. This diffractive-refractive optical system of see-through head-mounted display not only satisfies the demands of user"s factors in structure, but also with high resolution, very small chromatic aberration and distortion, and satisfies the need of augmented reality. In the end, the parameters of the diffractive surface are discussed.

  8. Isotopic diagnosis of peripheral thrombosis

    International Nuclear Information System (INIS)

    Cornu, Pierre; Scalet, Michel

    1975-01-01

    Radio-isotope diagnosis of peripheral venous thrombosis, using tracer doses of iodine-labelled fibrinogen, provides an important contribution to the solution of the worrying problem of pulmonary embolism due to latent phlebitis. This elegant and precise technique permits early diagnosis of venous thrombosis of the lower limbs at a subclinical stage. It has permitted determination of the frequency, both after surgery and after myocardial infarction, and above all, it provides an objective criterion for assessment of the efficacy of prophylactic measures proposed [fr

  9. Inverse axial mounting stiffness design for lithographic projection lenses.

    Science.gov (United States)

    Wen-quan, Yuan; Hong-bo, Shang; Wei, Zhang

    2014-09-01

    In order to balance axial mounting stiffness of lithographic projection lenses and the image quality under dynamic working conditions, an easy inverse axial mounting stiffness design method is developed in this article. Imaging quality deterioration at the wafer under different axial vibration levels is analyzed. The desired image quality can be determined according to practical requirements, and axial vibrational tolerance of each lens is solved with the damped least-squares method. Based on adaptive interval adjustment, a binary search algorithm, and the finite element method, the axial mounting stiffness of each lens can be traveled in a large interval, and converges to a moderate numerical solution which makes the axial vibrational amplitude of the lens converge to its axial vibrational tolerance. Model simulation is carried out to validate the effectiveness of the method.

  10. Preparation and mounting of adult Drosophila structures in Canada balsam.

    Science.gov (United States)

    Stern, David L; Sucena, Elio

    2012-03-01

    The Drosophila cuticle carries a rich array of morphological details. Thus, cuticle examination has had a central role in the history of genetics. To prepare fine "museum-quality," permanent slides, it is best to mount specimens in Canada Balsam. It is difficult to give precise recipes for Canada Balsam, because every user seems to prefer a slightly different viscosity. Dilute solutions spread easily and do not dry too rapidly while mounting specimens. The disadvantage is that there is actually less Balsam in a "drop" of the solution, and when dried, it can contract from the sides of the coverslip, sometimes disturbing the specimen. Unfortunately, there is no substitute for experience when using Canada Balsam. This protocol describes a procedure for mounting adult cuticles in Canada Balsam.

  11. Solar rotation measurements at Mount Wilson. Pt. 2

    International Nuclear Information System (INIS)

    Labonte, B.J.; Howard, R.; Carnegie Institution of Washington, Pasadena

    1981-01-01

    Possible sources of systematic error in solar Doppler rotational velocities are examined. Scattered light is shown to affect the Mount Wilson solar rotation results, but this effect is not enough to bring the spectroscopic results in coincidence with the sunspot rotation. Interference fringes at the spectrograph focus at Mount Wilson have in two intervals affected the rotation results. It has been possible to correlate this error with temperature and thus correct for it. A misalignment between the entrance and exit slits is a possible source of error, but for the Mount Wilson slit configuration the amplitude of this effect is negligibly small. Rapid scanning of the solar image also produces no measurable effect. (orig.)

  12. Linear and/or curvilinear rail mount system

    Science.gov (United States)

    Thomas, Jackie D. (Inventor); Harris, Lawanna L. (Inventor)

    2012-01-01

    One or more linear and/or curvilinear mounting rails are coupled to a structure. Each mounting rail defines a channel and at least one cartridge assembly is engaged in the channel. Each cartridge assembly includes a housing that slides within the channel. The housing defines a curvilinearly-shaped recess longitudinally aligned with the channel when the housing is in engagement therewith. The cartridge assembly also includes a cleat fitted in the recess for sliding engagement therealong. The cleat can be coupled to a fastener that passes through the mounting rail and the housing when the housing is so-engaged in the channel. The cleat is positioned in the recess by a position of the fastener.

  13. Peripheral formalin injection induces unique spinal cord microglial phenotypic changes

    Science.gov (United States)

    Fu, Kai-Yuan; Tan, Yong-Hui; Sung, Backil; Mao, Jianren

    2014-01-01

    Microglia are resident immune cells of brain and activated by peripheral tissue injury. In the present study, we investigated the possible induction of several microglial surface immunomolecules in the spinal cord, including leukocyte common antigen (LCA/CD45), MHC class I antigen, MHC class II antigen, Fc receptor, and CD11c following formalin injection into the rat’s hind paw. CD45 and MHC class I were upregulated in the activated microglia, which was evident on day 3 with the peak expression on day 7 following peripheral formalin injection. There was a very low basal expression of MHC class II, CD11c, and the Fc receptor, which did not change after the formalin injection. These results, for the first time, indicate that peripheral formalin injection can induce phenotypic changes of microglia with distinct upregulation of CD45 and MHC class I antigen. The data suggest that phenotypic changes of the activated microglia may be a unique pattern of central changes following peripheral tissue injury. PMID:19015000

  14. Square Van Atta reflector with conducting mounting flame

    DEFF Research Database (Denmark)

    Nielsen, Erik Dragø

    1970-01-01

    A theoretical and numerical analysis of square Van Atta reflectors has been carried out with or without a conducting plate, used for mounting of the antenna elements. The Van Atta reflector investigated has antenna elements which are parallel half-wave dipoles interconnected in pairs by transmiss......A theoretical and numerical analysis of square Van Atta reflectors has been carried out with or without a conducting plate, used for mounting of the antenna elements. The Van Atta reflector investigated has antenna elements which are parallel half-wave dipoles interconnected in pairs...

  15. Experimental study of some mounting brackets to support fuel elements

    International Nuclear Information System (INIS)

    Aubert, M.; Poglia, S.; Roche, R.

    1958-09-01

    In an atomic pile with vertical channels, fuel elements are stacked on one another. According to a possible assembly, fuel element can be contained by a graphite sleeve and be supported by a mounting bracket in this sleeve. Sleeves are then stacked on one another. The authors report the investigation of different designs for these mounting brackets. They describe their mechanical role and their mechanical, aerodynamic, neutronic and test conditions. They report tests performed on brackets made in graphite and on brackets made in stainless steel and graphite, and discuss the obtained results

  16. Mount Sinai Hospital's approach to Ontario's Health System Funding Reform.

    Science.gov (United States)

    Chalk, Tyler; Lau, Davina; Morgan, Matthew; Dietrich, Sandra; Beduz, Mary Agnes; Bell, Chaim M

    2014-01-01

    In April 2012, the Ontario government introduced Health System Funding Reform (HSFR), a transformational shift in how hospitals are funded. Mount Sinai Hospital recognized that moving from global funding to a "patient-based" model would have substantial operational and clinical implications. Adjusting to the new funding environment was set as a top corporate priority, serving as the strategic basis for re-examining and redesigning operations to further improve both quality and efficiency. Two years into HSFR, this article outlines Mount Sinai Hospital's approach and highlights key lessons learned. Copyright © 2014 Longwoods Publishing.

  17. Diagnostic approach to peripheral neuropathy

    Directory of Open Access Journals (Sweden)

    Misra Usha

    2008-01-01

    Full Text Available Peripheral neuropathy refers to disorders of the peripheral nervous system. They have numerous causes and diverse presentations; hence, a systematic and logical approach is needed for cost-effective diagnosis, especially of treatable neuropathies. A detailed history of symptoms, family and occupational history should be obtained. General and systemic examinations provide valuable clues. Neurological examinations investigating sensory, motor and autonomic signs help to define the topography and nature of neuropathy. Large fiber neuropathy manifests with the loss of joint position and vibration sense and sensory ataxia, whereas small fiber neuropathy manifests with the impairment of pain, temperature and autonomic functions. Electrodiagnostic (EDx tests include sensory, motor nerve conduction, F response, H reflex and needle electromyography (EMG. EDx helps in documenting the extent of sensory motor deficits, categorizing demyelinating (prolonged terminal latency, slowing of nerve conduction velocity, dispersion and conduction block and axonal (marginal slowing of nerve conduction and small compound muscle or sensory action potential and dennervation on EMG. Uniform demyelinating features are suggestive of hereditary demyelination, whereas difference between nerves and segments of the same nerve favor acquired demyelination. Finally, neuropathy is classified into mononeuropathy commonly due to entrapment or trauma; mononeuropathy multiplex commonly due to leprosy and vasculitis; and polyneuropathy due to systemic, metabolic or toxic etiology. Laboratory investigations are carried out as indicated and specialized tests such as biochemical, immunological, genetic studies, cerebrospinal fluid (CSF examination and nerve biopsy are carried out in selected patients. Approximately 20% patients with neuropathy remain undiagnosed but the prognosis is not bad in them.

  18. Intraoperative Ultrasound for Peripheral Nerve Applications.

    Science.gov (United States)

    Willsey, Matthew; Wilson, Thomas J; Henning, Phillip Troy; Yang, Lynda J-S

    2017-10-01

    Offering real-time, high-resolution images via intraoperative ultrasound is advantageous for a variety of peripheral nerve applications. To highlight the advantages of ultrasound, its extraoperative uses are reviewed. The current intraoperative uses, including nerve localization, real-time evaluation of peripheral nerve tumors, and implantation of leads for peripheral nerve stimulation, are reviewed. Although intraoperative peripheral nerve localization has been performed previously using guide wires and surgical dyes, the authors' approach using ultrasound-guided instrument clamps helps guide surgical dissection to the target nerve, which could lead to more timely operations and shorter incisions. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Peripheral Vestibular System Disease in Vestibular Schwannomas

    DEFF Research Database (Denmark)

    Møller, Martin Nue; Hansen, Søren; Caye-Thomasen, Per

    2015-01-01

    density of the peripheral vestibular nerve branches, and atrophy of the neuroepithelium of the vestibular end organs. In cases with small tumors, peripheral disease occurred only in the tissue structures innervated by the specific nerve from which the tumor originated. CONCLUSION: Vestibular schwannomas...... are associated with distinctive disease of the peripheral vestibular tissue structures, suggesting anterograde degeneration and that dizziness in these patients may be caused by deficient peripheral vestibular nerve fibers, neurons, and end organs. In smaller tumors, a highly localized disease occurs, which...

  20. Peripheral refractive correction and automated perimetric profiles.

    Science.gov (United States)

    Wild, J M; Wood, J M; Crews, S J

    1988-06-01

    The effect of peripheral refractive error correction on the automated perimetric sensitivity profile was investigated on a sample of 10 clinically normal, experienced observers. Peripheral refractive error was determined at eccentricities of 0 degree, 20 degrees and 40 degrees along the temporal meridian of the right eye using the Canon Autoref R-1, an infra-red automated refractor, under the parametric conditions of the Octopus automated perimeter. Perimetric sensitivity was then undertaken at these eccentricities (stimulus sizes 0 and III) with and without the appropriate peripheral refractive correction using the Octopus 201 automated perimeter. Within the measurement limits of the experimental procedures employed, perimetric sensitivity was not influenced by peripheral refractive correction.

  1. Peripheral visual performance enhancement by neurofeedback training.

    Science.gov (United States)

    Nan, Wenya; Wan, Feng; Lou, Chin Ian; Vai, Mang I; Rosa, Agostinho

    2013-12-01

    Peripheral visual performance is an important ability for everyone, and a positive inter-individual correlation is found between the peripheral visual performance and the alpha amplitude during the performance test. This study investigated the effect of alpha neurofeedback training on the peripheral visual performance. A neurofeedback group of 13 subjects finished 20 sessions of alpha enhancement feedback within 20 days. The peripheral visual performance was assessed by a new dynamic peripheral visual test on the first and last training day. The results revealed that the neurofeedback group showed significant enhancement of the peripheral visual performance as well as the relative alpha amplitude during the peripheral visual test. It was not the case in the non-neurofeedback control group, which performed the tests within the same time frame as the neurofeedback group but without any training sessions. These findings suggest that alpha neurofeedback training was effective in improving peripheral visual performance. To the best of our knowledge, this is the first study to show evidence for performance improvement in peripheral vision via alpha neurofeedback training.

  2. seasonal population dynamics of rodents of mount chilalo, arsi ...

    African Journals Online (AJOL)

    Preferred Customer

    ABSTRACT: A study on seasonal population dynamics of rodents was carried out on Mount. Chilalo from .... vegetation growth, availability of food and water, and ... vegetation (3,300–4,200 masl) (Alemayehu. Mengistu, 1975; APEDO and ABRDP, 2004). The mountain is one of the Afrotropical biodiversity hotspots areas.

  3. Vegetation types on Mount Akiki, Northern Luzon, Philippines

    NARCIS (Netherlands)

    Bout, I.E.

    2002-01-01

    Mount Akiki (16° 37’ N, 120° 53’ E, c. 2760 m alt.) is one of the highest mountain peaks in the Cordillera mountain range, Luzon Island, Philippines. It is situated in the municipality of Benguet, north-east of Baguio City (a world famous tourist city in the region) and is north-west of Mt Pulog,

  4. Kuidas koostada meeskonda - Mount Everesti ainetel / Marii Karell

    Index Scriptorium Estoniae

    Karell, Marii, 1980-

    2003-01-01

    Eesti meeskonna Mount Everesti tippu juhtinud Tõivo Sarmet selgitab toimunud ekspeditsiooni näitel, miks tema peab meeskonna komplekteerimisel oluliseimaks inimeste iseloomuomadusi. Ekstreemoludes hakkama saamiseks tuleb meeles pidada, et eesmärk on ühine ja kellegi ego ei tohi seda nurjata, rõhutab Sarmet. Kommenteerib Alar Sikk

  5. Nozzle Mounting Method Optimization Based on Robot Kinematic Analysis

    Science.gov (United States)

    Chen, Chaoyue; Liao, Hanlin; Montavon, Ghislain; Deng, Sihao

    2016-08-01

    Nowadays, the application of industrial robots in thermal spray is gaining more and more importance. A desired coating quality depends on factors such as a balanced robot performance, a uniform scanning trajectory and stable parameters (e.g. nozzle speed, scanning step, spray angle, standoff distance). These factors also affect the mass and heat transfer as well as the coating formation. Thus, the kinematic optimization of all these aspects plays a key role in order to obtain an optimal coating quality. In this study, the robot performance was optimized from the aspect of nozzle mounting on the robot. An optimized nozzle mounting for a type F4 nozzle was designed, based on the conventional mounting method from the point of view of robot kinematics validated on a virtual robot. Robot kinematic parameters were obtained from the simulation by offline programming software and analyzed by statistical methods. The energy consumptions of different nozzle mounting methods were also compared. The results showed that it was possible to reasonably assign the amount of robot motion to each axis during the process, so achieving a constant nozzle speed. Thus, it is possible optimize robot performance and to economize robot energy.

  6. Parallax error in the monocular head-mounted eye trackers

    DEFF Research Database (Denmark)

    Mardanbeigi, Diako; Witzner Hansen, Dan

    2012-01-01

    each parameter affects the error. The optimum distribution of the error (magnitude and direction) in the field of view varies for different applications. However, the results can be used for finding the optimum parameters that are needed for designing a head-mounted gaze tracker. It has been shown...

  7. Polynomial modal analysis of lamellar diffraction gratings in conical mounting.

    Science.gov (United States)

    Randriamihaja, Manjakavola Honore; Granet, Gérard; Edee, Kofi; Raniriharinosy, Karyl

    2016-09-01

    An efficient numerical modal method for modeling a lamellar grating in conical mounting is presented. Within each region of the grating, the electromagnetic field is expanded onto Legendre polynomials, which allows us to enforce in an exact manner the boundary conditions that determine the eigensolutions. Our code is successfully validated by comparison with results obtained with the analytical modal method.

  8. Evaluation of HOPG mounting possibilities for multiplexing spectrometers

    DEFF Research Database (Denmark)

    Groitl, Felix; Bartkowiak, Marek; Bergmann, Ryan M.

    2017-01-01

    Four different methods for mounting HOPG analyzer crystals on Si holders have been evaluated in the design process of the new multiplexing spectrometer CAMEA. Contrary to neutron optics used in standard spectrometers, the new instrument concept employs a series of analyzer segments behind each...

  9. Design of the GOES Telescope secondary mirror mounting

    Science.gov (United States)

    Hookman, Robert A.

    1989-01-01

    The GOES Telescope utilizes a flexure mounting system for the secondary mirror to minimize thermally induced distortions of the secondary mirror. The detailed design is presented along with a discussion of the microradian pointing requirements and how they were achieved. The methodology used to dynamically tune the flexure/secondary mirror assembly to minimize structural interactions will also be discussed.

  10. Vertically mounted bifacial photovoltaic modules: A global analysis

    International Nuclear Information System (INIS)

    Guo, Siyu; Walsh, Timothy Michael; Peters, Marius

    2013-01-01

    Bifacial PV (photovoltaic) modules have recently come to increasing attention and various system designs have been investigated. In this paper, a global comparison is made between vertically mounted bifacial modules facing East–West and conventionally mounted mono-facial modules. An analytical method is used to calculate the radiation received by these two module configurations. It is found that the answer to the question which of these two module configurations performs better strongly depends on three factors: (i) the latitude, (ii) the local diffuse fraction and (iii) the albedo. In a subsequent part of the paper, the minimum albedo required to result in a better performance for vertically mounted bifacial modules is calculated for every place in the world. The calculation is based on measured data of the diffuse light fraction and the results are shown in the form of a global map. Finally, the albedo requirements are compared with the measured global albedo distribution. The calculation allows a distinct decision which module configuration is more suitable for a certain place in the world. The result is also shown as a map defining the corresponding areas. - Highlights: • Vertically mounted bifacial module and conventionally monofacial module are compared. • The key factors affecting the performance of the two configurations are investigated. • Which module configuration is more suitable for each place is shown in a world map. • The minimum albedo for bifacial modules to have a better performance is calculated

  11. Birds of Mount Kisingiri, Nyanza Province, including a preliminary ...

    African Journals Online (AJOL)

    Mount Kisingiri comprises a much overlooked highland massif in southern Nyanza. Province with a hitherto ..... This imbalance in relative species abundance within a defined ecological niche could .... Hills is unsuitable for foraging or breeding but there is extensive savanna grassland and suitable ..... Columba guinea nf.

  12. Biogeographic patterns of forest diversity at mount Kasigau, Kenya ...

    African Journals Online (AJOL)

    The study reports 140 species, 46 were measured in only one plot, and affinities for 75 species to the Somalia-Masai (43%), Afromontane (29%), and Zanzibar- Inhambane (Coastal, 28%) floristic regions. Cluster and Indicator Species Analyses identified eight community types. Mount Kasigau uniquely conserves much ...

  13. Light Field Rendering for Head Mounted Displays using Pixel Reprojection

    DEFF Research Database (Denmark)

    Hansen, Anne Juhler; Klein, Jákup; Kraus, Martin

    2017-01-01

    Light field displays have advantages over traditional stereoscopic head mounted displays, for example, because they can overcome the vergence-accommodation conflict. However, rendering light fields can be a heavy task for computers due to the number of images that have to be rendered. Since much ...

  14. Improved resolution by mounting of tissue sections for laser microdissection.

    NARCIS (Netherlands)

    Dijk, M.C.R.F. van; Rombout, P.D.M.; Dijkman, H.B.P.M.; Ruiter, D.J.; Bernsen, M.R.

    2003-01-01

    BACKGROUND: Laser microbeam microdissection has greatly facilitated the procurement of specific cell populations from tissue sections. However, the fact that a coverslip is not used means that the morphology of the tissue sections is often poor. AIMS: To develop a mounting method that greatly

  15. Rollin' in Style!: Students Design Bike Mounted Skateboard Racks

    Science.gov (United States)

    Massey, Rick

    2008-01-01

    Recognizing the increasing popularity of skateboarding, the author has found a project that teaches design and manufacturing concepts--and, of equal importance, really gets his students motivated. He challenges them to design and build a skateboard rack that mounts easily on a bicycle. The project benefits students by teaching creativity, the…

  16. The mount Cameroon height determined from ground gravity data ...

    African Journals Online (AJOL)

    Abstract This paper deals with the accurate determination of mount Cameroon orthometric height, by combining ground gravity data, global navigation satellite system (GNSS) observations and global geopotential models. The elevation of the highest point (Fako) is computed above the WGS84 reference ellipsoid.

  17. Volcano ecology: flourishing on the flanks of Mount St. Helens

    Science.gov (United States)

    Rhonda Mazza; Charlie Crisafulli

    2016-01-01

    Mount St. Helens’ explosive eruption on May 18, 1980, was a pivotal moment in the field of disturbance ecology. The subsequent sustained, integrated research effort has shaped the development of volcano ecology, an emerging field of focused research. Excessive heat, burial, and impact force are some of the disturbance mechanisms following an eruption. They are also...

  18. Mount St. Helens 30 years later: a landscape reconfigured.

    Science.gov (United States)

    Rhonda Mazza

    2010-01-01

    On May 18, 1980, after two months of tremors, Mount St. Helens erupted spectacularly and profoundly changed a vast area surrounding the volcano. The north slope of the mountain catastrophically failed, forming the largest landslide witnessed in modern times. The largest lobe of this debris avalanche raced 14 miles down the Toutle River...

  19. Mount St. Helens: Still erupting lessons 31 years later

    Science.gov (United States)

    Rhonda Mazza; Charlie Crisafulli; Fred Swanson

    2011-01-01

    The massive volcanic eruption of Mount St. Helens 31 years ago provided the perfect backdrop for studying the earliest stages of forest development. Immediately after the eruption, some areas of the blast area were devoid of life. On other parts of the volcanic landscape, many species survived, although their numbers were greatly reduced. Reassembly began at many...

  20. Assessing climate change impacts on water balance in the Mount

    Indian Academy of Sciences (India)

    A statistical downscaling known for producing station-scale climate information from GCM output was preferred to evaluate the impacts of climate change within the Mount Makiling forest watershed, Philippines. The lumped hydrologic BROOK90 model was utilized for the water balance assessment of climate change ...

  1. Ethnobotanical survey of \\'wild\\' woody plant resources at Mount ...

    African Journals Online (AJOL)

    This paper focuses on the naming and use of plants by Taita who live at Mount Kasigau in Kenya's Eastern Arc Mountains. Plant vouchers and ethnobotanical data were compiled from transects and within 55 ecological plots, and during participant observations, home surveys, and semi-structured interviews with residents.

  2. Forest Carbon Stocks in Woody Plants of Mount Zequalla Monastery ...

    African Journals Online (AJOL)

    Carbon sequestration through forestry has the potential to play a significant role in ameliorating global environmental problems such as atmospheric accumulation of GHG's and climate change.The present study was undertaken to estimate forest carbon stock along altitudinal gradient in Mount Zequalla Monastery forest.

  3. Astrophotography on the go using short exposures with light mounts

    CERN Document Server

    Ashley, Joseph

    2015-01-01

    No longer are heavy, sturdy, expensive mounts and tripods required to photograph deep space. With today's advances in technology, all that is required is an entry-DSLR and an entry level GoTo telescope. Here is all of the information needed to start photographing the night sky without buying expensive tracking mounts. By using multiple short exposures and combining them with mostly ‘freeware’ computer programs, the effect of image rotation can be minimized to a point where it is undetectable in normal astrophotography, even for a deep-sky object such as a galaxy or nebula. All the processes, techniques, and equipment needed to use inexpensive, lightweight altazimuth and equatorial mounts and very short exposures photography to image deep space objects are explained, step-by-step, in full detail, supported by clear, easy to understand graphics and photographs.   Currently available lightweight mounts and tripods are identified and examined from an economic versus capability perspective to help users deter...

  4. 25 years of ecological change at Mount St. Helens.

    Science.gov (United States)

    V.H. Dale; C.M. Crisafulli; F.J. Swanson

    2005-01-01

    18 May 2005 marks the 25th anniversary of the massive eruption of Mount St. Helens. This eruption involved diverse geological processes (1) that disturbed forests, meadows, lakes, an drivers (2) (see the figure). A huge landslide and searing flows of hot gases and pumic framents (pyroclastic flows) inundated 60 km2 of land, obliterating...

  5. Geologic Map of Mount Mazama and Crater Lake Caldera, Oregon

    Science.gov (United States)

    Bacon, Charles R.

    2008-01-01

    Crater Lake partly fills one of the most spectacular calderas of the world, an 8-by-10-km basin more than 1 km deep formed by collapse of the volcano known as Mount Mazama (fig. 1) during a rapid series of explosive eruptions about 7,700 years ago. Having a maximum depth of 594 m, Crater Lake is the deepest lake in the United States. Crater Lake National Park, dedicated in 1902, encompasses 645 km2 of pristine forested and alpine terrain, including the lake itself, virtually all of Mount Mazama, and most of the area of the geologic map. The geology of the area was first described in detail by Diller and Patton (1902) and later by Williams (1942), whose vivid account led to international recognition of Crater Lake as the classic collapse caldera. Because of excellent preservation and access, Mount Mazama, Crater Lake caldera, and the deposits formed by the climactic eruption constitute a natural laboratory for study of volcanic and magmatic processes. For example, the climactic ejecta are renowned among volcanologists as evidence for systematic compositional zonation within a subterranean magma chamber. Mount Mazama's climactic eruption also is important as the source of the widespread Mazama ash, a useful Holocene stratigraphic marker throughout the Pacific Northwest, adjacent Canada, and offshore. A detailed bathymetric survey of the floor of Crater Lake in 2000 (Bacon and others, 2002) provides a unique record of postcaldera eruptions, the interplay between volcanism and filling of the lake, and sediment transport within this closed basin. Knowledge of the geology and eruptive history of the Mount Mazama edifice, greatly enhanced by the caldera wall exposures, gives exceptional insight into how large volcanoes of magmatic arcs grow and evolve. Lastly, the many smaller volcanoes of the High Cascades beyond the limits of Mount Mazama are a source of information on the flux of mantle-derived magma through the region. General principles of magmatic and eruptive

  6. Peripheral Defocus of the Monkey Crystalline Lens With Accommodation in a Lens Stretcher

    Science.gov (United States)

    Maceo Heilman, Bianca; Manns, Fabrice; Ruggeri, Marco; Ho, Arthur; Gonzalez, Alex; Rowaan, Cor; Bernal, Andres; Arrieta, Esdras; Parel, Jean-Marie

    2018-01-01

    Purpose To characterize the peripheral defocus of the monkey crystalline lens and its changes with accommodation. Methods Experiments were performed on 15 lenses from 11 cynomolgus monkey eyes (age: 3.8–12.4 years, postmortem time: 33.5 ± 15.3 hours). The tissue was mounted in a motorized lens stretcher to allow for measurements of the lens in the accommodated (unstretched) and unaccommodated (stretched) states. A custom-built combined laser ray tracing and optical coherence tomography system was used to measure the paraxial on-axis and off-axis lens power for delivery angles ranging from −20° to +20° (in air). For each delivery angle, peripheral defocus was quantified as the difference between paraxial off-axis and on-axis power. The peripheral defocus of the lens was compared in the unstretched and stretched states. Results On average, the paraxial on-axis lens power was 52.0 ± 3.4 D in the unstretched state and 32.5 ± 5.1 D in the stretched state. In both states, the lens power increased with increasing delivery angle. From 0° to +20°, the relative peripheral lens power increased by 10.7 ± 1.4 D in the unstretched state and 7.5 ± 1.6 D in the stretched state. The change in field curvature with accommodation was statistically significant (P lens has greater curvature or relative peripheral power. Conclusions The cynomolgus monkey lens has significant accommodation-dependent curvature of field, which suggests that the lens asserts a significant contribution to the peripheral optical performance of the eye that also varies with the state of accommodation.

  7. Exploring Virtual Worlds With Head-Mounted Displays

    Science.gov (United States)

    Chung, James C.; Harris, Mark R.; Brooks, Frederick P.; Fuchs, Henry; Kelley, Michael T.; Hughes, John W.; Ouh-Young, Ming; Cheung, Clement; Holloway, Richard L.; Pique, Michael

    1989-09-01

    For nearly a decade the University of North Carolina at Chapel Hill has been conducting research in the use of simple head-mounted displays in "real-world" applications. Such units provide the user with non-holographic true three-dimensional information, since the kinetic depth effect, stereoscopy, and other visual cues combine to immerse the user in a "virtual world" which behaves like the real world in some respects. UNC's head-mounted display was built inexpensively from commercially available off-the-shelf components. Tracking of the the user's head position and orientation is performed by a Polhemus Navigation Sciences' 3SPACE* tracker. The host computer uses the tracking information to generate updated images corresponding to the user's new left eye and right eye views. The images are broadcast to two liquid crystal television screens (220x320 pixels) mounted on a horizontal shelf at the user's forehead. The user views these color screens through half-silvered mirrors, enabling the computer-generated image to be superimposed upon the user's real physical environment. The head-mounted display has been incorporated into existing molecular modeling and architectural applications being developed at UNC. In molecular structure studies, chemists are presented with a room-sized molecule with which they can interact in a manner more intuitive than that provided by conventional two-dimensional displays and dial boxes. Walking around and through the large molecule may provide quicker understanding of its structure, and such problems as drug-enzyme docking may be approached with greater insight. In architecture, the head-mounted display enables clients to better appreciate three-dimensional designs, which may be misinterpreted in their conventional two-dimensional form by untrained eyes. The addition of a treadmill to the system provides additional kinesthetic input into the understanding of building size and scale.

  8. Zircon reveals protracted magma storage and recycling beneath Mount St. Helens

    Science.gov (United States)

    Claiborne, L.L.; Miller, C.F.; Flanagan, D.M.; Clynne, M.A.; Wooden, J.L.

    2010-01-01

    Current data and models for Mount St. Helens volcano (Washington, United States) suggest relatively rapid transport from magma genesis to eruption, with no evidence for protracted storage or recycling of magmas. However, we show here that complex zircon age populations extending back hundreds of thousands of years from eruption age indicate that magmas regularly stall in the crust, cool and crystallize beneath the volcano, and are then rejuvenated and incorporated by hotter, young magmas on their way to the surface. Estimated dissolution times suggest that entrained zircon generally resided in rejuvenating magmas for no more than about a century. Zircon elemental compositions reflect the increasing influence of mafic input into the system through time, recording growth from hotter, less evolved magmas tens of thousands of years prior to the appearance of mafic magmas at the surface, or changes in whole-rock geochemistry and petrology, and providing a new, time-correlated record of this evolution independent of the eruption history. Zircon data thus reveal the history of the hidden, long-lived intrusive portion of the Mount St. Helens system, where melt and crystals are stored for as long as hundreds of thousands of years and interact with fresh influxes of magmas that traverse the intrusive reservoir before erupting. ?? 2010 Geological Society of America.

  9. Rhizocarpon calibration curve for the Aoraki/Mount Cook area of New Zealand

    Science.gov (United States)

    Lowell, Thomas V.; Schoenenberger, Katherine; Deddens, James A.; Denton, George H.; Smith, Colby; Black, Jessica; Hendy, Chris H.

    2005-05-01

    Development of Rhizocarpon growth curve from the Aoraki/Mount Cook area of New Zealand provides a means to assess Little Ice Age glacier behaviour and suggests approaches that have wider application. Employing a sampling strategy based on large populations affords the opportunity to assess which of various metrics (e.g. single largest, average of five largest, mean of an entire population) best characterise Rhizocarpon growth patterns. The 98% quantile from each population fitted with a quadric curve forms a reliable representation of the growth pattern. Since this metric does not depend on the original sample size, comparisons are valid where sample strategy must be adapted to local situations or where the original sample size differs. For the Aoraki/Mount Cook area a surface 100 years old will have a 98% quantile lichen diameter of 34.3 mm, whereas a 200-year-old surface will have a lichen diameter of 73.7 mm. In the Southern Alps, constraints from the age range of calibration points, the flattening of the quadric calibration curve and ecological factors limit the useful age range to approximately 250 years. Copyright

  10. The mechanisms of fine particle generation and electrification during Mount St. Helens volcanic eruption

    Science.gov (United States)

    Cheng, R. J.

    1982-01-01

    Microscopical investigation of volcanic ash collected from ground stations during Mount St. Helens eruptions reveal a distinctive bimodel size distribution with high concentrations of particle ranges at (1) 200-100 microns and (2) 20-0.1 microns. Close examination of individual particles shows that most larger ones are solidified magma particles of porous pumice with numerous gas bubbles in the interior and the smaller ones are all glassy fragments without any detectable gas bubbles. Elemental analysis demonstrates that the fine fragments all have a composition similar to that of the larger pumice particles. Laboratory experiments suggest that the formation of the fine fragments is by bursting of glassy bubbles from a partially solidified surface of a crystallizing molten magma particle. The production of gas bubbles is due to the release of absorbed gases in molten magma particles when solubility decreases during phase transition. Diffusion cloud chamber experiments strongly indicate that sub-micron volcanic fragments are highly hygroscopic and extremely active as cloud condensation nuclei. Ice crystals also are evidently formed on those fragments in a supercooled (-20 C) cloud chamber. It has been reported that charge generation from ocean volcanic eruptions is due to contact of molten lava with sea water. This seems to be insufficient to explain the observed rapid and intense lightning activities over Mount St. Helens eruptions. Therefore, a hypothesis is presented here that highly electrically charged fine solid fragments are ejected by bursting of gas bubbles from the surface of a crystallizing molten magma particles.

  11. The Effects of Degradational Factors on the Ecosystem of Mount Madra

    Science.gov (United States)

    Efe, R.; Soykan, A.; Sönmez, S.; Cürebal, I.

    2009-04-01

    environment of Kozak Plataeu, and in addition to this, quarrying activity has recently begun in the area around Burhaniye. All these activities have led to problems such as erosion, decreased biodiversity, and pollution of water sources on Mount Madra. The forest clearances which have been made, for various reasons, on the northern and southern slopes of Mount Madra, have caused the topsoil to be worn away by surface water. The most striking examples of this can be seen on Mount Şabla (1111m) and on the southern slopes of Maya peak (1344m). The trimming recently carried out by the Forestry Commission on sections of Mount Madra has badly damaged the forest's vegetation and in a short space of time caused irreversible harm to the ecosystem of the mountain. For thousands of years, parts of the top of Mount Madra and the Kozak plateau have been used as summer grounds and, as a result, the forest has been cleared from a wide section. On the north-facing slopes of Mount Madra, the number of chestnut trees (Castanea sativa) found within pine woods is increasing daily. The pine trees around the chestnuts are being chopped down in order to increase the number of chestnut trees, whose fruit are harvested for the economic benefit they bring. The pine forests are, for this reason, in constant decline. Forest roads, both planned and unplanned, have led to further destruction of forest vegetation. Apart from the forest vegetation of the Mountain, other natural resources are under threat; particularly water sources. Facilities for fish farming have been built with no pre-planning or research, leading to the clearance of forest and pollution of the environment. Mount Madra is an important water source for the rivers in the surrounding areas. It is the source of the Madra and Karınca Rivers which flow into the Aegean Sea, the Kocaçay River which feeds Manyas Lake and several tributaries of the Bakırçay River. The protection of Mount Madra and its freshwater sources and biodiversity is

  12. Atherectomy for peripheral arterial disease.

    Science.gov (United States)

    Ambler, Graeme K; Radwan, Rami; Hayes, Paul D; Twine, Christopher P

    2014-03-17

    Symptomatic peripheral arterial disease may be treated by a number of options including exercise therapy, angioplasty, stenting and bypass surgery. Atherectomy is an alternative technique where atheroma is excised by a rotating cutting blade. The objective of this review was to analyse randomised controlled trials comparing atherectomy against any established treatment for peripheral arterial disease in order to evaluate the effectiveness of atherectomy. The Cochrane Peripheral Vascular Diseases Group Trials Search Co-ordinator searched the Specialised Register (last searched November 2013) and CENTRAL (2013, Issue 10). Trials databases were searched for details of ongoing or unpublished studies. Randomised controlled trials (RCTs) comparing atherectomy and other established treatments were selected for inclusion. All participants had symptomatic peripheral arterial disease with either claudication or critical limb ischaemia and evidence of lower limb arterial disease. Two review authors (GA and CT) screened studies for inclusion, extracted data and assessed the quality of the trials. Any disagreements were resolved through discussion. Four trials were included with a total of 220 participants (118 treated with atherectomy, 102 treated with balloon angioplasty) and 259 treated vessels (129 treated with atherectomy, 130 treated with balloon angioplasty). All studies compared atherectomy with angioplasty. No study was properly powered or assessors blinded to the procedures and there was a high risk of selection, attrition, detection and reporting biases.The estimated risk of success was similar between the treatment modalities although the confidence interval (CI) was compatible with small benefits of either treatment for the initial procedural success rate (Mantel-Haenszel risk ratio (RR) 0.92, 95% CI 0.44 to 1.91, P = 0.82), patency at six months (Mantel-Haenszel RR 0.92, 95% CI 0.51 to 1.66, P = 0.79) and patency at 12 months (Mantel-Haenszel RR 1.17, 95% CI 0

  13. Contrast-enhanced peripheral MRA

    DEFF Research Database (Denmark)

    Nielsen, Yousef W; Thomsen, Henrik S

    2012-01-01

    MRI contrast agent is injected intravenously and T1-weighted images are acquired in the subsequent arterial first-pass phase. In order to achieve high quality MR angiograms without interfering venous contamination or artifacts, a number of factors need to be taken into account. This includes magnetic......-state MRA. Gadolinium(Gd)-based contrast agents are used for CE-MRA of the peripheral arteries. Extracellular Gd agents have a pharmacokinetic profile similar to iodinated contrast media. Accordingly, these agents are employed for first-pass MRA. Blood-pool Gd-based agents are characterized by prolonged...... intravascular stay, due to macromolecular structure or protein binding. These agents can be used for first-pass, as well as steady-state MRA. Some Gd-based contrast agents with low thermodynamic stability have been linked to development of nephrogenic systemic fibrosis in patients with severe renal...

  14. Taxane-Induced Peripheral Neurotoxicity

    Directory of Open Access Journals (Sweden)

    Roser Velasco

    2015-04-01

    Full Text Available Taxane-derived agents are chemotherapy drugs widely employed in cancer treatment. Among them, paclitaxel and docetaxel are most commonly administered, but newer formulations are being investigated. Taxane antineoplastic activity is mainly based on the ability of the drugs to promote microtubule assembly, leading to mitotic arrest and apoptosis in cancer cells. Peripheral neurotoxicity is the major non-hematological adverse effect of taxane, often manifested as painful neuropathy experienced during treatment, and it is sometimes irreversible. Unfortunately, taxane-induced neurotoxicity is an uncertainty prior to the initiation of treatment. The present review aims to dissect current knowledge on real incidence, underlying pathophysiology, clinical features and predisposing factors related with the development of taxane-induced neuropathy.

  15. Galvanic corrosion study of aluminium alloy plates mounted to stainless and mild steel bolts by accelerated exposure test

    OpenAIRE

    MREMA, Emmanuel; ITOH, Yoshito; KANEKO, Akira; HIROHATA, Mikihito

    2016-01-01

    Despite the fact that aluminium alloy members have a proven durability over stainless steel members, their joint fasteners like bolts, nuts and washers are drawn from steel material due to aluminium alloy inferior mechanical properties. Bare contact between aluminium alloy members and stainless steel fasteners results to galvanic corrosion of aluminium alloy members. A corrosion behaviour study was carried out on different aluminium alloy types with different surface treatments mounted to sta...

  16. Peripheral Developing Odontoma or Peripheral Ameloblastic Fibroodontoma: A Rare Challenging Case

    Directory of Open Access Journals (Sweden)

    Saede Atarbashi Moghadam

    2016-01-01

    Full Text Available Peripheral odontogenic lesions are considered to be rare within the classification of odontogenic tumors. They share the same microscopic characteristics of their central counterparts. Here, we report an ulcerated mass of the maxillary gingiva that on histopathological examination was diagnosed as peripheral developing odontoma or peripheral ameloblastic fibroodontoma. The diagnosis of this tumor is challenging and may lead to unnecessary treatment.

  17. Helicopter magnetic and electromagnetic surveys at Mounts Adams, Baker and Rainier, Washington: implications for debris flow hazards and volcano hydrology

    Science.gov (United States)

    Finn, Carol A.; Deszcz-Pan, Maria

    2011-01-01

    High‐resolution helicopter magnetic and electromagnetic (HEM) data flown over the rugged, ice‐covered Mt. Adams, Mt. Baker and Mt. Rainier volcanoes (Washington), reveal the distribution of alteration, water and ice thickness essential to evaluating volcanic landslide hazards. These data, combined with geological mapping and rock property measurements, indicate the presence of appreciable thicknesses (>500 m) of water‐saturated hydrothermally altered rock west of the modern summit of Mount Rainier in the Sunset Amphitheater region and in the central core of Mount Adams north of the summit. Alteration at Mount Baker is restricted to thinner (<300 m) zones beneath Sherman Crater and the Dorr Fumarole Fields. The EM data identified water‐saturated rocks from the surface to the detection limit (100–200 m) in discreet zones at Mt. Rainier and Mt Adams and over the entire summit region at Mt. Baker. The best estimates for ice thickness are obtained over relatively low resistivity (<800 ohm‐m) ground for the main ice cap on Mt. Adams and over most of the summit of Mt. Baker. The modeled distribution of alteration, pore fluids and partial ice volumes on the volcanoes helps identify likely sources for future alteration‐related debris flows, including the Sunset Amphitheater region at Mt. Rainier, steep cliffs at the western edge of the central altered zone at Mount Adams and eastern flanks of Mt. Baker.

  18. Sedimentology, Behavior, and Hazards of Debris Flows at Mount Rainier, Washington

    Science.gov (United States)

    Scott, K.M.; Vallance, J.W.; Pringle, P.T.

    1995-01-01

    Mount Rainier is potentially the most dangerous volcano in the Cascade Range because of its great height, frequent earthquakes, active hydrothermal system, and extensive glacier mantle. Many debris flows and their distal phases have inundated areas far from the volcano during postglacial time. Two types of debris flows, cohesive and noncohesive, have radically different origins and behavior that relate empirically to clay content. The two types are the major subpopulations of debris flows at Mount Rainier. The behavior of cohesive flows is affected by the cohesion and adhesion of particles; noncohesive flows are dominated by particle collisions to the extent that particle cataclasis becomes common during near-boundary shear. Cohesive debris flows contain more than 3 to 5 percent of clay-size sediment. The composition of these flows changed little as they traveled more than 100 kilometers from Mount Rainier to inundate parts of the now-populated Puget Sound lowland. They originate as deep-seated failures of sectors of the volcanic edifice, and such failures are sufficiently frequent that they are the major destructional process of Mount Rainier's morphologic evolution. In several deposits of large cohesive flows, a lateral, megaclast-bearing facies (with a mounded or hummocky surface) contrasts with a more clay-rich facies in the center of valleys and downstream. Cohesive flows at Mount Rainier do not correlate strongly with volcanic activity and thus can recur without warning, possibly triggered by non-magmatic earthquakes or by changes in the hydrothermal system. Noncohesive debris flows contain less than 3 to 5 percent clay-size sediment. They form most commonly by bulking of sediment in water surges, but some originate directly or indirectly from shallow slope failures that do not penetrate the hydrothermally altered core of the volcano. In contrast with cohesive flows, most noncohesive flows transform both from and to other flow types and are, therefore, the

  19. Imaging of the peripheral vascular system

    International Nuclear Information System (INIS)

    Gould, S.A.; Pond, G.D.; Pinsky, S.; Moss, G.S.; Srikantaswamy, S.; Ryo, U.Y.

    1984-01-01

    This book is limited neither to the peripheral vascular system nor to diagnostic imaging techniques. Its 18 chapters cover nonimaging blood-flow techniques (Doppler ultrasound, plethysmography) as well as noninvasive and invasive imaging techniques (ultrasound, computed tomography, radionuclide digital-subtraction angiography, and contrast angiography). These are applied not only to the peripheral vascular system but also to the aorta and vena cava

  20. Beauty and cuteness in peripheral vision

    Science.gov (United States)

    Kuraguchi, Kana; Ashida, Hiroshi

    2015-01-01

    Guo et al. (2011) showed that attractiveness was detectable in peripheral vision. Since there are different types of attractiveness (Rhodes, 2006), we investigated how beauty and cuteness are detected in peripheral vision with a brief presentation. Participants (n = 45) observed two Japanese female faces for 100 ms, then were asked to respond which face was more beautiful (or cuter). The results indicated that both beauty and cuteness were detectable in peripheral vision, but not in the same manner. Discrimination rates for judging beauty were invariant in peripheral and central vision, while discrimination rates for judging cuteness declined in peripheral vision as compared with central vision. This was not explained by lower resolution in peripheral vision. In addition, for male participants, it was more difficult to judge cuteness than beauty in peripheral vision, thus suggesting that gender differences can have a certain effect when judging cuteness. Therefore, central vision might be suitable for judging cuteness while judging beauty might not be affected by either central or peripheral vision. This might be related with the functional difference between beauty and cuteness. PMID:25999883

  1. Flat mount preparation for observation and analysis of zebrafish embryo specimens stained by whole mount in situ hybridization.

    Science.gov (United States)

    Cheng, Christina N; Li, Yue; Marra, Amanda N; Verdun, Valerie; Wingert, Rebecca A

    2014-07-17

    The zebrafish embryo is now commonly used for basic and biomedical research to investigate the genetic control of developmental processes and to model congenital abnormalities. During the first day of life, the zebrafish embryo progresses through many developmental stages including fertilization, cleavage, gastrulation, segmentation, and the organogenesis of structures such as the kidney, heart, and central nervous system. The anatomy of a young zebrafish embryo presents several challenges for the visualization and analysis of the tissues involved in many of these events because the embryo develops in association with a round yolk mass. Thus, for accurate analysis and imaging of experimental phenotypes in fixed embryonic specimens between the tailbud and 20 somite stage (10 and 19 hours post fertilization (hpf), respectively), such as those stained using whole mount in situ hybridization (WISH), it is often desirable to remove the embryo from the yolk ball and to position it flat on a glass slide. However, performing a flat mount procedure can be tedious. Therefore, successful and efficient flat mount preparation is greatly facilitated through the visual demonstration of the dissection technique, and also helped by using reagents that assist in optimal tissue handling. Here, we provide our WISH protocol for one or two-color detection of gene expression in the zebrafish embryo, and demonstrate how the flat mounting procedure can be performed on this example of a stained fixed specimen. This flat mounting protocol is broadly applicable to the study of many embryonic structures that emerge during early zebrafish development, and can be implemented in conjunction with other staining methods performed on fixed embryo samples.

  2. The role of EXT and growth signalling pathways in osteochondroma and its progression towards secondary peripheral chondrosarcoma

    NARCIS (Netherlands)

    Hameetman, Liesbeth

    2007-01-01

    Osteochondroma is a cartilage capped benign bone tumour, arising at the external surface of bones preformed by endochondral ossification. A small percentage of osteochondromas can progress towards its malignant counterpart, secondary peripheral chondrosarcoma. About 15% of osteochondromas occur in

  3. Workpiece Temperature Variations During Flat Peripheral Grinding

    Science.gov (United States)

    Smirnov, Vitalii A.; Repko, Aleksandr V.

    2018-06-01

    The paper presents the results of researches of temperature variations during flat peripheral grinding. It is shown that the temperature variations of the workpiece can reach 25...30% of the average values, which can lead to some thermal defects. A nonlinear two-dimensional thermophysical grinding model is suggested. It takes into account local changes in the cutting conditions: the fluctuation of the cut layer and the cutting force, the thermal impact of the cutting grains, and the presence of surface cavities in the intermittent wheel. For the numerical solution of the problem, the method of finite differences is adapted. Researches of the method stability and convergence are made, taking into account the specific nature of the problem. A high accuracy of the approximation of the boundary conditions and the nonlinear heat equation is provided. An experimental verification of the proposed thermophysical model was carried out with the use of installation for simultaneous measurement of the grinding force and temperature. It is shown that the discrepancy between the theoretical and experimental values of the grinding temperature does not exceed 5%. The proposed thermophysical model makes it possible to predict with high accuracy the temperature variations during grinding by the wheel periphery.

  4. Peripherally applied opioids for postoperative pain

    DEFF Research Database (Denmark)

    Nielsen, B N; Henneberg, S W; Schmiegelow, K

    2015-01-01

    BACKGROUND: Opioids applied peripherally at the site of surgery may produce postoperative analgesia with few side effects. We performed this systematic review to evaluate the analgesic effect of peripherally applied opioids for acute postoperative pain. METHODS: We searched PubMed (1966 to June...... 2013), Embase (1980 to June 2013), and the Cochrane Central Register of Controlled Trials (The Cochrane Library 2013, Issue 6). Randomized controlled trials investigating the postoperative analgesic effect of peripherally applied opioids vs. systemic opioids or placebo, measured by pain intensity...... difference -5 mm, 95% CI: -7 to -3) for peripherally applied opioids vs. placebo and statistically significant increased time to first analgesic (mean difference 153 min, 95% CI: 41-265). When preoperative inflammation was reported (five studies), peripherally applied opioids significantly improved...

  5. Mount Meager Volcano, Canada: a Case Study for Landslides on Glaciated Volcanoes

    Science.gov (United States)

    Roberti, G. L.; Ward, B. C.; van Wyk de Vries, B.; Falorni, G.; Perotti, L.; Clague, J. J.

    2015-12-01

    Mount Meager is a strato-volcano massif in the Northern Cascade Volcanic Arc (Canada) that erupted in 2350 BP, the most recent in Canada. To study the stability of the Massif an international research project between France ( Blaise Pascal University), Italy (University of Turin) and Canada (Simon Fraser University) and private companies (TRE - sensing the planet) has been created. A complex history of glacial loading and unloading, combined with weak, hydrothermally altered rocks has resulted in a long record of catastrophic landslides. The most recent, in 2010 is the third largest (50 x 106 m3) historical landslide in Canada. Mount Meager is a perfect natural laboratory for gravity and topographic processes such as landslide activity, permafrost and glacial dynamics, erosion, alteration and uplift on volcanoes. Research is aided by a rich archive of aerial photos of the Massif (1940s up to 2006): complete coverage approximately every 10 years. This data set has been processed and multi-temporal, high resolution Orthophoto and DSMs (Digital Surface Models) have been produced. On these digital products, with the support on field work, glacial retreat and landslide activity have been tracked and mapped. This has allowed for the inventory of unstable areas, the identification of lava flows and domes, and the general improvement on the geologic knowledge of the massif. InSAR data have been used to monitor the deformation of the pre-2010 failure slope. It will also be used to monitor other unstable slopes that potentially can evolve to catastrophic collapses of up to 1 km3 in volume, endangering local communities downstream the volcano. Mount Meager is definitively an exceptional site for studying the dynamics of a glaciated, uplifted volcano. The methodologies proposed can be applied to other volcanic areas with high erosion rates such as Alaska, Cascades, and the Andes.

  6. Mounting of Biomaterials for Use in Ophthalmic Cell Therapies.

    Science.gov (United States)

    Harkin, Damien G; Dunphy, Siobhan E; Shadforth, Audra M A; Dawson, Rebecca A; Walshe, Jennifer; Zakaria, Nadia

    2017-11-01

    When used as scaffolds for cell therapies, biomaterials often present basic handling and logistical problems for scientists and surgeons alike. The quest for an appropriate mounting device for biomaterials is therefore a significant and common problem. In this review, we provide a detailed overview of the factors to consider when choosing an appropriate mounting device including those experienced during cell culture, quality assurance, and surgery. By way of example, we draw upon our combined experience in developing epithelial cell therapies for the treatment of eye diseases. We discuss commercially available options for achieving required goals and provide a detailed analysis of 4 experimental designs developed within our respective laboratories in Australia, the United Kingdom, and Belgium.

  7. Apparatus for mounting photovoltaic power generating systems on buildings

    Science.gov (United States)

    Russell, Miles C [Lincoln, MA

    2009-08-18

    Rectangular photovoltaic (PV) modules are mounted on a building roof by mounting stands that are distributed in rows and columns. Each stand comprises a base plate and first and second different height brackets attached to opposite ends of the base plate. Each first and second bracket comprises two module-support members. One end of each module is pivotally attached to and supported by a first module-support member of a first bracket and a second module-support member of another first bracket. At its other end each module rests on but is connected by flexible tethers to module-support members of two different second brackets. The tethers are sized to allow the modules to pivot up away from the module-support members on which they rest to a substantially horizontal position in response to wind uplift forces.

  8. Whole mount nuclear fluorescent imaging: convenient documentation of embryo morphology.

    Science.gov (United States)

    Sandell, Lisa L; Kurosaka, Hiroshi; Trainor, Paul A

    2012-11-01

    Here, we describe a relatively inexpensive and easy method to produce high quality images that reveal fine topological details of vertebrate embryonic structures. The method relies on nuclear staining of whole mount embryos in combination with confocal microscopy or conventional wide field fluorescent microscopy. In cases where confocal microscopy is used in combination with whole mount nuclear staining, the resulting embryo images can rival the clarity and resolution of images produced by scanning electron microscopy (SEM). The fluorescent nuclear staining may be performed with a variety of cell permeable nuclear dyes, enabling the technique to be performed with multiple standard microscope/illumination or confocal/laser systems. The method may be used to document morphology of embryos of a variety of organisms, as well as individual organs and tissues. Nuclear stain imaging imposes minimal impact on embryonic specimens, enabling imaged specimens to be utilized for additional assays. Copyright © 2012 Wiley Periodicals, Inc.

  9. Siting study for small platform-mounted industrial energy reactors

    International Nuclear Information System (INIS)

    1975-07-01

    Utilizing an existing 313 MW(t) ship propulsion reactor design, a concept has been formulated for a floating platform-mounted nuclear plant and an evaluation has been made to determine reductions in construction time and cost achievable by repetitive platform construction in a shipyard. Concepts and estimates are presented for siting platform-mounted nuclear plants at the location of industrial facilities where the nuclear plants would furnish industrial process heat and/or electrical power. The representative industrial site designated for this study is considered typical of sites that might be used along the extensive network of navigable canals adjacent to the ocean and is similar to potential sites along the inland waterways of the United States

  10. Preparation of source mounts for 4π counting

    International Nuclear Information System (INIS)

    Johnson, E.P.

    1991-01-01

    The 4πβ/γ counter in the ANSTO radioisotope standards laboratory at Lucas Heights constitutes part of the Australian national standard for radioactivity. Sources to be measured in the counter must be mounted on a substrate which is strong enough to withstand careful handling and transport. The substrate must also be electrically conducting to minimise counting errors caused by charging of the source, and it must have very low superficial density so that little or none of the radiation is absorbed. The entire process of fabrication of VYNS films, coating them with gold/palladium and transferring them to source mount rings, as carried out in the radioisotope standards laboratory, is documented. 3 refs., 2 tabs., 6 figs

  11. Righteousness and identity formation in the Sermon on the Mount

    Directory of Open Access Journals (Sweden)

    Francois P. Viljoen

    2013-03-01

    Full Text Available Righteousness is an important term in the first gospel and has a significant concentration in the Sermon on the Mount. The argument in this article is that the first gospel has a community building function. Matthew intentionally uses the word ‘righteousness’ in the Sermon on the Mount as an instrument to define the identity of his community. Though righteousness can be used in a soteriological sense, it is argued that Matthew mainly uses it in an ethical sense. By righteousness Matthew refers to the proper behavioural norms and attitudes for his community. Commitment to Jesus forms the central focus of the community’s identity. Their discipleship is demonstrated by doing the will of God as defined and interpreted by Jesus. Doing the will of God in such a manner is what Matthew regards as the distinguishing mark of this community. Thus they would surpass the righteousness of the scribes and Pharisees.

  12. Tsunamis generated by eruptions from mount st. Augustine volcano, alaska.

    Science.gov (United States)

    Kienle, J; Kowalik, Z; Murty, T S

    1987-06-12

    During an eruption of the Alaskan volcano Mount St. Augustine in the spring of 1986, there was concern about the possibility that a tsunami might be generated by the collapse of a portion of the volcano into the shallow water of Cook Inlet. A similar edifice collapse of the volcano and ensuing sea wave occurred during an eruption in 1883. Other sea waves resulting in great loss of life and property have been generated by the eruption of coastal volcanos around the world. Although Mount St. Augustine remained intact during this eruptive cycle, a possible recurrence of the 1883 events spurred a numerical simulation of the 1883 sea wave. This simulation, which yielded a forecast of potential wave heights and travel times, was based on a method that could be applied generally to other coastal volcanos.

  13. Ground mounted photovoltaic installations. Guide for an impact study

    International Nuclear Information System (INIS)

    2011-01-01

    Legally, an impact study must be performed for ground mounted photovoltaic installations with a power greater than 250 kW. This guide is aimed at helping the actors of the photovoltaic sector to perform impact studies. After the description of the characteristics of a photovoltaic installation (principles, technical characteristics of a ground mounted installation, impact of photovoltaic systems on climate) and a presentation of the legal framework (European commitments, Grenelle de l'Environnement, applicable procedures), this report present the objectives and approach of an impact study, describes how the environment is taken into account from the early stages of a project, how the impact study is to be prepared. The last part describes the different components of the impact study: legal content, project description, analysis of the site initial status and environment, analysis of the project effects, rationale for the choice of the project

  14. The auriferous placer at Mount Robert, Pietersburg Greenstone belt

    International Nuclear Information System (INIS)

    Saager, R.; Muff, R.

    1986-01-01

    The Mount Robert gold placer near Potgietersrus occurs in coarse, matrix-supported conglomerates of the Uitkyk Formation within the Pietersburg greenstone belt. Sedimentological and mineralogical investigations indicate that the conglomerates and the ore minerals were derived from a greenstone provenance, and that they were deposited in a braided river environment within a rapidly subsiding trough. Lack of sedimentological concentration of the heavy minerals is considered to be the main reason for the low and erratic gold grades encountered (usually below 1 g/t) and, thus, the failure of all past mining ventures. The mineralogical composition of the Mount Robert ore closely resembles that of the Witwatersrand deposits. However, uraninite is absent, probably as a result of its complete removal by weathering processes. Remaining small uranium concentrations can still be detected within the conglomerates where they occur associated with grains of carbonaceous matter, leucoxene aggregates, and secondary iron-hydroxides. U3O8 values found in the conglomerates are given

  15. Fluorescent visualization of macromolecules in Drosophila whole mounts.

    Science.gov (United States)

    Ramos, Ricardo Guelerman Pinheiro; Machado, Luciana Claudia Herculano; Moda, Livia Maria Rosatto

    2010-01-01

    The ability to determine the expression dynamics of individual genes "in situ" by visualizing the precise spatial and temporal distribution of their products in whole mounts by histochemical and immunocytochemical reactions has revolutionized our understanding of cellular processes. Drosophila developmental genetics was one of the fields that benefited most from these technologies, and a variety of fluorescent methods were specifically designed for investigating the localization of developmentally important proteins and cell markers during embryonic and post embryonic stages of this model organism. In this chapter we present detailed protocols for fluorescence immunocytochemistry of whole mount embryos, imaginal discs, pupal retinas, and salivary glands of Drosophila melanogaster, as well as methods for fluorescent visualization of specific subcellular structures in these tissues.

  16. Binocular Rivalry in Helmet-Mounted Display Applications

    Science.gov (United States)

    1975-06-01

    research apparatus. 31 ., simple magnifying ophthalmic lenses were used, mounted in eyeglass frames. These were 2. 5 diopter lenses for both eyes to...wear eyeglasses with 2. 5 diopter lenses. The focal length of these lenses was 15. 5 inches and the eye waa accommodated at infinity when objects were...HMD luminance is positively related to I-I•D visibility, while ambient scene luminance bears an inverse relation- ship to HMD visibility. Scene

  17. Method to mount defect fuel elements i transport casks

    International Nuclear Information System (INIS)

    Borgers, H.; Deleryd, R.

    1996-01-01

    Leaching or otherwise failed fuel elements are mounted in special containers that fit into specially designed chambers in a transportation cask for transport to reprocessing or long-time storage. The fuel elements are entered into the container under water in a pool. The interior of the container is dried before transfer to the cask. Before closing the cask, its interior, and the exterior of the container are dried. 2 figs

  18. Apollo telescope mount thermal systems unit thermal vacuum test

    Science.gov (United States)

    Trucks, H. F.; Hueter, U.; Wise, J. H.; Bachtel, F. D.

    1971-01-01

    The Apollo Telescope Mount's thermal systems unit was utilized to conduct a full-scale thermal vacuum test to verify the thermal design and the analytical techniques used to develop the thermal mathematical models. Thermal vacuum test philosophy, test objectives configuration, test monitoring, environment simulation, vehicle test performance, and data correlation are discussed. Emphasis is placed on planning and execution of the thermal vacuum test with particular attention on problems encountered in conducting a test of this maguitude.

  19. Quality assurance during construction and mounting of the Balakovo NPP

    International Nuclear Information System (INIS)

    Savkin, A.I.; Vorob'ev, N.G.; Kugrysheva, M.A.

    1984-01-01

    Measures directed at opportune comissioning of the first unit of Balakovo NPP with the caracity 1000 MW(el.) are briefly described. A high quality of construction and mounting works is achieved due to a high level of engeneering preparation in the industry, organization of daily control over the works implementation and quality of products and materials supplied, by the improvement of automation and introduction of progressive forms of organization and remuneration

  20. Psychometric Assessment of Stereoscopic Head-Mounted Displays

    Science.gov (United States)

    2016-06-29

    Journal Article 3. DATES COVERED (From – To) Jan 2015 - Dec 2015 4. TITLE AND SUBTITLE PSYCHOMETRIC ASSESSMENT OF STEREOSCOPIC HEAD- MOUNTED DISPLAYS...to render an immersive three-dimensional constructive environment. The purpose of this effort was to quantify the impact of aircrew vision on an...simulated tasks requiring precise depth discrimination. This work will provide an example validation method for future stereoscopic virtual immersive

  1. Ionic mechanisms in peripheral pain.

    Science.gov (United States)

    Fransén, Erik

    2014-01-01

    Chronic pain constitutes an important and growing problem in society with large unmet needs with respect to treatment and clear implications for quality of life. Computational modeling is used to complement experimental studies to elucidate mechanisms involved in pain states. Models representing the peripheral nerve ending often address questions related to sensitization or reduction in pain detection threshold. In models of the axon or the cell body of the unmyelinated C-fiber, a large body of work concerns the role of particular sodium channels and mutations of these. Furthermore, in central structures: spinal cord or higher structures, sensitization often refers not only to enhanced synaptic efficacy but also to elevated intrinsic neuronal excitability. One of the recent developments in computational neuroscience is the emergence of computational neuropharmacology. In this area, computational modeling is used to study mechanisms of pathology with the objective of finding the means of restoring healthy function. This research has received increased attention from the pharmaceutical industry as ion channels have gained increased interest as drug targets. Computational modeling has several advantages, notably the ability to provide mechanistic links between molecular and cellular levels on the one hand and functions at the systems level on the other hand. These characteristics make computational modeling an additional tool to be used in the process of selecting pharmaceutical targets. Furthermore, large-scale simulations can provide a framework to systematically study the effects of several interacting disease parameters or effects from combinations of drugs. © 2014 Elsevier Inc. All rights reserved.

  2. Conceptual Design of Bottom-mounted Control Rod Drive Mechanism

    International Nuclear Information System (INIS)

    Lee, Jin Haeng; Kim, Sanghaun; Yoo, Yeonsik; Cho, Yeonggarp; Kim, Dongmin; Kim, Jong In

    2013-01-01

    The arrangement of the BMCRDMs and irradiation holes in the core is therefore easier than that of the top-mounted CRDM. Hence, many foreign research reactors, such as JRR-3M, JMTR, OPAL, and CARR, have adopted the BMCRDM concept. The purpose of this paper is to introduce the basic design concept on the BMCRDM. The major differences of the CRDMs between HANARO and KJRR are compared, and the design features and individual system of the BMCRDM for the KJRR are described. The Control Rod Drive Mechanism (CRDM) is a device to regulate the reactor power by changing the position of a Control Absorber Rod (CAR) and to shut down the reactor by fully inserting the CAR into the core within a specified time. The Bottom-Mounted CRDM (BMCRDM) for the KiJang Research Reactor (KJRR) is a quite different design concept compared to the top-mounted CRDM such as HANARO and JRTR. The main drive mechanism of the BMCRDM is located in a Reactivity Control Mechanism (RCM) room under the reactor pool bottom, which makes the interference with equipment in the reactor pool reduced

  3. A concept of active mount for space applications

    Science.gov (United States)

    Souleille, A.; Lampert, T.; Lafarga, V.; Hellegouarch, S.; Rondineau, A.; Rodrigues, G.; Collette, C.

    2018-06-01

    Sensitive payloads mounted on top of launchers are subjected to many sources of disturbances during the flight. The most severe dynamic loads arise from the ignition of the motors, gusts, pressure fluctuations in the booster and from the separation of the boosters. The transmission of these dynamic forces can be reduced by mounting payloads on passive isolators, which comes at the expense of harmful amplifications of the motion at low frequency due to suspension resonances. To bypass this shortcoming, this paper presents a novel concept of active mount for aerospace payloads, which is easy to install, and meets two objectives. The first one is a high damping authority on both suspension resonances and flexible resonances without compromising the isolation and large stability margins of the closed loop system due to the collocation of the actuator and the sensor. The second one is a broadband reduction of the dynamic force transmitted to the payload, which was achieved in terms of 16 dB. The concept is presented in the first part of the paper and studied numerically and experimentally on a single degree of freedom isolator. A commercial isolator has been chosen for the purpose of the demonstration. The second part of the paper is dedicated to experimental validations on multi-degree of freedom scaled test benches. It is shown that the force feedback allows damping of both suspension and flexible modes (first and second modes, respectively), and significantly reducing the force transmitted in some broad frequency ranges.

  4. On-field mounting position estimation of a lidar sensor

    Science.gov (United States)

    Khan, Owes; Bergelt, René; Hardt, Wolfram

    2017-10-01

    In order to retrieve a highly accurate view of their environment, autonomous cars are often equipped with LiDAR sensors. These sensors deliver a three dimensional point cloud in their own co-ordinate frame, where the origin is the sensor itself. However, the common co-ordinate system required by HAD (Highly Autonomous Driving) software systems has its origin at the center of the vehicle's rear axle. Thus, a transformation of the acquired point clouds to car co-ordinates is necessary, and thereby the determination of the exact mounting position of the LiDAR system in car coordinates is required. Unfortunately, directly measuring this position is a time-consuming and error-prone task. Therefore, different approaches have been suggested for its estimation which mostly require an exhaustive test-setup and are again time-consuming to prepare. When preparing a high number of LiDAR mounted test vehicles for data acquisition, most approaches fall short due to time or money constraints. In this paper we propose an approach for mounting position estimation which features an easy execution and setup, thus making it feasible for on-field calibration.

  5. Local Sabahans’ Satisfaction with Level of Access to Mount Kinabalu

    Directory of Open Access Journals (Sweden)

    Bidder Christy

    2014-01-01

    Full Text Available This study analyzes the local Sabahans’ satisfaction with the level of access to Mount Kinabalu in Sabah, Malaysian Borneo. Specifically, it examines the number of complaints by local Sabahans regarding access and their perception of changes in accessibility to the mountain. Interviews with Sabah Parks and Sutera Sanctuary Lodges were conducted and questionnaires were distributed to local residents to collect data. The results show that there were intense complaints regarding the climbing cost and extensive waiting time to secure a confirmed booking at the outset of price increases. However, the researchers could not locate any recently published complaints. Respondents who have previously climbed Mount Kinabalu perceive the mountain to be less accessible for local Sabahans now due to a less affordable cost and a longer waiting time. Those who have not climbed Mount Kinabalu also think the climbing cost has become less affordable for local Sabahans, but they do not perceive that to be causing the mountain less accessible for local Sabahans.

  6. A concept of active mount for space applications

    Science.gov (United States)

    Souleille, A.; Lampert, T.; Lafarga, V.; Hellegouarch, S.; Rondineau, A.; Rodrigues, G.; Collette, C.

    2017-10-01

    Sensitive payloads mounted on top of launchers are subjected to many sources of disturbances during the flight. The most severe dynamic loads arise from the ignition of the motors, gusts, pressure fluctuations in the booster and from the separation of the boosters. The transmission of these dynamic forces can be reduced by mounting payloads on passive isolators, which comes at the expense of harmful amplifications of the motion at low frequency due to suspension resonances. To bypass this shortcoming, this paper presents a novel concept of active mount for aerospace payloads, which is easy to install, and meets two objectives. The first one is a high damping authority on both suspension resonances and flexible resonances without compromising the isolation and large stability margins of the closed loop system due to the collocation of the actuator and the sensor. The second one is a broadband reduction of the dynamic force transmitted to the payload, which was achieved in terms of 16 dB. The concept is presented in the first part of the paper and studied numerically and experimentally on a single degree of freedom isolator. A commercial isolator has been chosen for the purpose of the demonstration. The second part of the paper is dedicated to experimental validations on multi-degree of freedom scaled test benches. It is shown that the force feedback allows damping of both suspension and flexible modes (first and second modes, respectively), and significantly reducing the force transmitted in some broad frequency ranges.

  7. Conceptual Design of Bottom-mounted Control Rod Drive Mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Haeng; Kim, Sanghaun; Yoo, Yeonsik; Cho, Yeonggarp; Kim, Dongmin; Kim, Jong In [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    The arrangement of the BMCRDMs and irradiation holes in the core is therefore easier than that of the top-mounted CRDM. Hence, many foreign research reactors, such as JRR-3M, JMTR, OPAL, and CARR, have adopted the BMCRDM concept. The purpose of this paper is to introduce the basic design concept on the BMCRDM. The major differences of the CRDMs between HANARO and KJRR are compared, and the design features and individual system of the BMCRDM for the KJRR are described. The Control Rod Drive Mechanism (CRDM) is a device to regulate the reactor power by changing the position of a Control Absorber Rod (CAR) and to shut down the reactor by fully inserting the CAR into the core within a specified time. The Bottom-Mounted CRDM (BMCRDM) for the KiJang Research Reactor (KJRR) is a quite different design concept compared to the top-mounted CRDM such as HANARO and JRTR. The main drive mechanism of the BMCRDM is located in a Reactivity Control Mechanism (RCM) room under the reactor pool bottom, which makes the interference with equipment in the reactor pool reduced.

  8. Vibration aging of diesel-engine mounted electrical equipment

    International Nuclear Information System (INIS)

    Lee, B.J.; Morton, W.C.

    1994-01-01

    The Emergency Diesel Generator (EDG) in a Nuclear Power Plant is considered to be a component which is essential to safe plant operation. Failures of auxiliary equipment directly mounted on the EDG creates costly repairs, and compromises the engine's availability and reliability. Although IEEE-323 requires addressing of safety-related components due to mechanically induced vibration, very few guidelines exist in the nuclear industry to show how this may be accounted for. Most engine vendors rely on the empirical experience data as the basis of their evaluation for vibration. Upgrade of engine controls, addition of monitoring devices and other engine modifications require design and installation of new equipment to be mounted directly on the engine. This necessitates the evaluation for engine-induced vibration which is considered to be one of the most severe design parameters. This paper discusses the engine vibration characteristics, and the acquisition of extensive field vibration data on the diesel engine under operating conditions. The data is then used to develop life cycle vibration qualification test profiles that can be applied with confidence in a laboratory environment to qualify engine-mounted equipment. The intent is to validate a product's ability to survive under worst case, extended service on-engine conditions. This paper describes the procedures and approaches used to achieve those goals, and provides developed profile examples and test results

  9. The Observatory as Laboratory: Spectral Analysis at Mount Wilson Observatory

    Science.gov (United States)

    Brashear, Ronald

    2018-01-01

    This paper will discuss the seminal changes in astronomical research practices made at the Mount Wilson Observatory in the early twentieth century by George Ellery Hale and his staff. Hale’s desire to set the agenda for solar and stellar astronomical research is often described in terms of his new telescopes, primarily the solar tower observatories and the 60- and 100-inch telescopes on Mount Wilson. This paper will focus more on the ancillary but no less critical parts of Hale’s research mission: the establishment of associated “physical” laboratories as part of the observatory complex where observational spectral data could be quickly compared with spectra obtained using specialized laboratory equipment. Hale built a spectroscopic laboratory on the mountain and a more elaborate physical laboratory in Pasadena and staffed it with highly trained physicists, not classically trained astronomers. The success of Hale’s vision for an astronomical observatory quickly made the Carnegie Institution’s Mount Wilson Observatory one of the most important astrophysical research centers in the world.

  10. Design and functional tests of the Euclid grism mount

    Science.gov (United States)

    Rossin, Ch.; Grange, R.; Caillat, A.; Costille, A.; Sanchez, P.; Ceria, W.

    2017-11-01

    The Euclid mission selected by ESA in the Cosmic Vision program is dedicated to understand dark energy and dark matter. One of the probes based on detection of Baryonic Acoustic Oscillations required the redshift of millions of galaxies. This massive spectroscopic survey relies on the Near Infrared SpectroPhotometer (NISP) using grism in slitless mode. In this Euclid NISP context, we designed a cryogenic mount for the four grisms of the spectroscopic channel. This mount has to maintain optical performances and alignment at the cryogenic temperature of 120K and to survive launch vibrations. Due to a very small mass and volume budget allowed in the Grism Wheel Assembly our design relies on a weight relief Invar ring glued to the grism by tangential flexures. Tangential flexures have the advantage of small height but the drawback of less decoupling capabilities than bipods. We will present the design of the mount and the integration and functional tests to stay within the 60 nm RMS transmitted wavefront error budget allowed to the grism.

  11. Peripheral cemento-ossifying fibroma of maxilla.

    Science.gov (United States)

    Chatterjee, Anirban; Ajmera, Neha; Singh, Amit

    2010-07-01

    Peripheral cemento-ossifying fibroma is a reactive gingival overgrowth occurring frequently in anterior maxilla. It is a slow-growing benign tumor which may lead to pathologic migration and other periodontal problems, so it should be excised as soon as possible. The recurrence rate of peripheral cemento-ossifying fibroma is reported to be 8% to 20%, so a close postoperative follow-up is required. Herein, we are reporting a similar case of peripheral cemento-ossifying fibroma in the maxillary anterior region.

  12. CT characteristics of peripheral organizing pneumonia

    International Nuclear Information System (INIS)

    Yang, Seong Oh; Choi, Chul Soon; Kim, Myung Joon; Lee, Kyung Soo; Choi, Hyung Sik; Jun, Young Hwan; Park, Yong Koo

    1988-01-01

    Diagnostic dilemma of persistent mass-forming parenchymal opacity in the lung periphery occurs occasionally in the realm of diagnostic radiology. Until recently, literature on the role of computed tomography in peripheral organizing pneumonia, which is difficult to differentiate from malignancy, has little been published. We experienced one case of pathologically proven organizing pneumonia diagnosed preoperatively by chest CT. When it comes to solitary peripheral mass density in the lung, we think that CT can be proved useful in the diagnosis of benign organizing pneumonia by showing regular and smoothly corrugate margin, peripheral contrast enhancement with inner low density, and air-trapping by intervening normal lung parenchyma.

  13. Peripheral facial nerve dysfunction: CT evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Disbro, M.A.; Harnsberger, H.R.; Osborn, A.G.

    1985-06-01

    Peripheral facial nerve dysfunction may have a clinically apparent or occult cause. The authors reviewed the clinical and radiographic records of 36 patients with peripheral facial nerve dysfunction to obtain information on the location of the suspected lesion and the number, sequence, and type of radiographic evaluations performed. Inadequate clinical evaluations before computed tomography (CT) was done and unnecessary CT examinations were also noted. They have suggested a practical clinical and radiographic scheme to evaluate progressive peripheral facial dysfunction with no apparent cause. If this scheme is applied, unnecessary radiologic tests and delays in diagnosis and treatment may be avoided.

  14. Immersive virtual walk-through development for tokamak using active head mounted display

    International Nuclear Information System (INIS)

    Dutta, Pramit

    2015-01-01

    A fully immersive virtual walk-through of the SST-1 tokamak has been developed. The virtual walkthrough renders the virtual model of SST-1 tokamak through a active stereoscopic head mounted display to visualize the virtual environment. All locations inside and outside of the reactor can be accessed and reviewed. Such a virtual walkthrough provides a 1:1 scale visualization of all components of the tokamak. To achieve such a virtual model, the graphical details of the tokamak CAD model are enhanced. Such enhancements are provided to improve lighting conditions at various locations, texturing of components to have a realistic visual effect and 360° rendering for ease of access. The graphical enhancements also include the redefinition of the facets to optimize the surface triangles to remove lags in display during visual rendering. Two separate algorithms are developed to interact with the virtual model. A fly-by algorithm, developed using C#, uses inputs from a commercial joystick to navigate within the virtual environment. The second algorithm uses the IR and gyroscopic tracking system of the head mounted display to render view as per the current pose of the user within the virtual environment and the direction of view. Such a virtual walk-thorough can be used extensively for design review and integration, review of new components, operator training for remote handling, operations, upgrades of tokamak, etc. (author)

  15. Effect of fabric mounting method and backing material on bloodstain patterns of drip stains on textiles.

    Science.gov (United States)

    Chang, J Y M; Michielsen, S

    2016-05-01

    Textiles may provide valuable bloodstain evidence to help piece together events or activities at violent crime scenes. However, in spite of over 75 years of research, there are still difficulties encountered in many cases in the interpretation and identification of bloodstains on textiles. In this study, we dripped porcine blood onto three types of fabric (plain woven, single jersey knit, and denim) that are supported in four different ways (hard, taut, loose, and semi-hard, i.e., fabric laid on denim). These four mounting methods represent different ways in which a textile may be present when blood from a violent act lands on it. This study investigates how the fabric mounting method and backing material affect the appearance of drip stains on textiles. We found that bloodstain patterns formed on fabric lying flat on a hard surface were very different from when the same fabric was suspended loosely. We also found that bloodstains formed on the technical back of single jersey knit were vastly different from those on the technical face. Interestingly, some drip stains showed blood passing through the textile and leaving a stain behind it that resembled insect stains. By observing, recording, and describing how a blood stained textile is found or presented at the scene, the analyst may be able to better understand bloodstains and bloodstain patterns on textiles, which could be useful to confirm or refute a witness's account of how blood came to be where it was found after a bloodshed event.

  16. The timing of Late Pleistocene glaciation at Mount Wilhelm, Papua New Guinea

    Science.gov (United States)

    Mills, Stephanie; Barrows, Timothy; Hope, Geoff; Pillans, Brad; Fifield, Keith

    2016-04-01

    The highlands of New Guinea were the most extensively glaciated area in the Asian tropical region during the Late Pleistocene. Evidence for glaciation is widespread on most of the mountain peaks above ~3500 m. Glacial landforms include both valley and ice cap forms, but the timing of glaciation remains constrained to only a few local areas. This paper focuses on Mount Wilhelm, which is situated in the central southern region of Papua New Guinea at 5.78°S and is the highest peak (4510 m a.s.l.) We focus on a south easterly valley (Pindaunde Valley) emanating from the peak, where large moraines indicate the maximum ice extent of a valley glacier ~5 km long. Within this extensive moraine complex, recessional moraines document the retreat of the glacier towards the summit region. In order to determine the timing of deglaciation, we collected samples for surface exposure dating using 36Cl and 10Be from diorite boulders positioned on moraine crests. The ages indicate that maximum ice extent was attained during the last glacial maximum (LGM) and that ice remained near its maximum extent until after 15 ka but persisted at higher elevations almost until the Holocene. These results are similar to those described from Mt Giluwe to the northwest of Mount Wilhelm, where an ice cap reached its maximum extent at the LGM and remained there for around 3-4,000 years. This indicates that full glacial conditions were only brief in this region of the tropics.

  17. PERIPHERAL NEUROPATHY ELECTROPHYSIOLOGICAL SCREENING IN CHILDREN WITH CELIAC DISEASE

    Directory of Open Access Journals (Sweden)

    Şedat IŞIKAY

    2015-06-01

    Full Text Available Background The involvement of the peripheral nervous system in children with celiac disease is particularly rare. Objective The aim of this study was to assess the need for neurophysiological testing in celiac disease patients without neurological symptoms in order to detect early subclinical neuropathy and its possible correlations with clinical and demographic characteristics. Methods Two hundred and twenty consecutive children with celiac disease were screened for neurological symptoms and signs, and those without symptoms or signs were included. Also, patients with comorbidities associated with peripheral neuropathy or a history of neurological disease were excluded. The remaining 167 asymptomatic patients as well as 100 control cases were tested electro-physiologically for peripheral nervous system diseases. Motor nerve conduction studies, including F-waves, were performed for the median, ulnar, peroneal, and tibial nerves, and sensory nerve conduction studies were performed for the median, ulnar, and sural nerves with H reflex of the soleus muscle unilaterally. All studies were carried out using surface recording electrodes. Normative values established in our laboratory were used. Results Evidence for subclinical neuropathy was not determined with electrophysiological studies in any of the participants. Conclusion In this highly selective celiac disease group without any signs, symptoms as well as the predisposing factors for polyneuropathy, we did not determine any cases with neuropathy. With these results we can conclude that in asymptomatic cases with celiac disease electrophysiological studies are not necessary. However, larger studies with the electrophysiological studies performed at different stages of disease at follow-ups are warranted.

  18. Development of a Double Glass Mounting Method Using Formaldehyde Alcohol Azocarmine Lactophenol (FAAL) and its Evaluation for Permanent Mounting of Small Nematodes.

    Science.gov (United States)

    Zahabiun, Farzaneh; Sadjjadi, Seyed Mahmoud; Esfandiari, Farideh

    2015-01-01

    Permanent slide preparation of nematodes especially small ones is time consuming, difficult and they become scarious margins. Regarding this problem, a modified double glass mounting method was developed and compared with classic method. A total of 209 nematode samples from human and animal origin were fixed and stained with Formaldehyde Alcohol Azocarmine Lactophenol (FAAL) followed by double glass mounting and classic dehydration method using Canada balsam as their mounting media. The slides were evaluated in different dates and times, more than four years. Different photos were made with different magnification during the evaluation time. The double glass mounting method was stable during this time and comparable with classic method. There were no changes in morphologic structures of nematodes using double glass mounting method with well-defined and clear differentiation between different organs of nematodes in this method. Using this method is cost effective and fast for mounting of small nematodes comparing to classic method.

  19. Peripheral Exophytic Oral Lesions: A Clinical Decision Tree

    Directory of Open Access Journals (Sweden)

    Hamed Mortazavi

    2017-01-01

    Full Text Available Diagnosis of peripheral oral exophytic lesions might be quite challenging. This review article aimed to introduce a decision tree for oral exophytic lesions according to their clinical features. General search engines and specialized databases including PubMed, PubMed Central, Medline Plus, EBSCO, Science Direct, Scopus, Embase, and authenticated textbooks were used to find relevant topics by means of keywords such as “oral soft tissue lesion,” “oral tumor like lesion,” “oral mucosal enlargement,” and “oral exophytic lesion.” Related English-language articles published since 1988 to 2016 in both medical and dental journals were appraised. Upon compilation of data, peripheral oral exophytic lesions were categorized into two major groups according to their surface texture: smooth (mesenchymal or nonsquamous epithelium-originated and rough (squamous epithelium-originated. Lesions with smooth surface were also categorized into three subgroups according to their general frequency: reactive hyperplastic lesions/inflammatory hyperplasia, salivary gland lesions (nonneoplastic and neoplastic, and mesenchymal lesions (benign and malignant neoplasms. In addition, lesions with rough surface were summarized in six more common lesions. In total, 29 entities were organized in the form of a decision tree in order to help clinicians establish a logical diagnosis by a stepwise progression method.

  20. Microbiological testing of devices used in maintaining peripheral venous catheters

    Directory of Open Access Journals (Sweden)

    Fernanda de Paula Rossini

    Full Text Available ABSTRACT Objective: to evaluate the use of peripheral venous catheters based on microbiological analysis of devices (dressing and three-way stopcocks and thus contribute to the prevention and infection control. Methods: this was a prospective study of microbiological analysis of 30 three-way stopcocks (external surfaces and lumens and 30 dressing used in maintaining the peripheral venous catheters of hospitalized adult patients. Results: all external surfaces, 40% of lumens, and 86.7% of dressing presented bacterial growth. The main species isolated in the lumen were 50% coagulase-negative Staphylococcus, 14.3% Staphylococcus aureus, and 14.3% Pseudomonas aeruginosa. Fifty nine percent of multidrug-resistant bacteria were isolated of the three-way stopcocks, 42% of the lumens, and 44% of the dressing with a predominance of coagulase-negative Staphylococcus resistant to methicillin. Besides, 18% gram-negative bacteria with resistance to carbapenems were identified from multidrug-resistant bacteria on the external surfaces of the three-way stopcocks. Conclusion: it is important to emphasize the isolation of coagulase-negative Staphylococcus and gram-negative bacteria resistant to methicillin and carbapenems in samples of devices, respectively, which reinforces the importance of nursing care in the maintenance of the biologically safe environment as well as prevention and infection control practices.

  1. Forming the stress state of a vibroisolated building in the process of mounting rubber steel vibration isolator

    Directory of Open Access Journals (Sweden)

    Dashevskiy Mikhail Aronovich

    2015-12-01

    Full Text Available The necessity to specificate the formation process of stress-strain state of buildings in the construction process is a new problem which requires including real production characteristics going beyond calculation models into calculation methods. Today the construction process lacks this specification. When mounting vibroisolators the stress-strein of a structure state is changing. The mounting method of vibroisolators is patented and consists in multistage successive compression loading of each vibroisolator with the constant speed and following fixation of this displacement. The specified engineering method of rubber-steel pads calculation in view of change of their form during deformation, nonlinearity, rheological processes is offered. Resilient pads look like rubber plates rectangular in plane reinforced on the basic surfaces with metal sheets. The influence of a time-variable static load and free vibrations of loaded pads are considered.

  2. Invasin of Yersinia pseudotuberculosis activates human peripheral B cells.

    OpenAIRE

    Lundgren, E; Carballeira, N; Vazquez, R; Dubinina, E; Bränden, H; Persson, H; Wolf-Watz, H

    1996-01-01

    The Yersinia pseudotuberculosis cell surface-located protein invasin was found to promote binding between the pathogen and resting peripheral B cells via beta 1 integrin receptors (CD29). B cells responded by expressing several activation markers and by growing, In contrast, T cells did not react, although these cells express CD29. An isogenic invA mutant failed to activate B cells. The mutation could be complemented by providing the invA+ gene in trans. Purified invasin alone did not activat...

  3. 76 FR 2370 - Mount Storm Hydro, LLC; Notice of Preliminary Permit Application Accepted for Filing and...

    Science.gov (United States)

    2011-01-13

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 13863-000] Mount Storm..., Motions To Intervene, and Competing Applications January 6, 2011. On October 14, 2010, Mount Storm Hydro... (FPA), proposing to study the feasibility of the Mount Storm Pumped Storage Project to be located near...

  4. EDITORIAL MODERN TECHNOLOGY IN PERIPHERAL HEALTH ...

    African Journals Online (AJOL)

    hi-tech

    2004-06-01

    Jun 1, 2004 ... new technology to peripheral health care systems in developing countries. ... and maintenance of medical equipment in Africa, citing information ... operating laboratory equipment, and for emergency lighting for operating ...

  5. Haemopoietic progenitor cells in human peripheral blood

    International Nuclear Information System (INIS)

    Zwaan, F.E.

    1980-01-01

    The purpose of the investigation reported is to purify haemopoietic progenitor cells from human peripheral blood using density gradient centrifugation in order to isolate a progenitor cell fraction without immunocompetent cells. The purification technique of peripheral blood flow colony forming unit culture (CFU-c) by means of density gradient centrifugation and a combined depletion of various rosettes is described. The results of several 'in vitro' characteristics of purified CFU-c suspensions and of the plasma clot diffusion chamber culture technique are presented. Irradiation studies revealed that for both human bone marrow and peripheral blood the CFU-c were less radioresistant than clusters. Elimination of monocytes (and granulocytes) from the test suspensions induced an alteration in radiosensitivity pararmeters. The results obtained with the different techniques are described by analysing peripheral progenitor cell activity in myeloproliferative disorders. (Auth.)

  6. Allogeneic Peripheral Blood Stem Cell Harvest

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Allogeneic Peripheral Blood Stem Cell Harvest. Mobilization protocol. G-CSF 10 mcg/Kg / day for 5 days. Pheresis. Cobe Spectra; Haemonetics mcs+. Enumeration. CD34 counts; Cfu-GM assays.

  7. Side Effects: Nerve Problems (Peripheral Neuropathy)

    Science.gov (United States)

    Nerve problems, such as peripheral neuropathy, can be caused by cancer treatment. Learn about signs and symptoms of nerve changes. Find out how to prevent or manage nerve problems during cancer treatment.

  8. Angioplasty and stent placement - peripheral arteries

    Science.gov (United States)

    ... medlineplus.gov/ency/article/007393.htm Angioplasty and stent placement - peripheral arteries To use the sharing features ... inside the arteries and block blood flow. A stent is a small, metal mesh tube that keeps ...

  9. Peripheral myelin protein 22 alters membrane architecture

    Science.gov (United States)

    Mittendorf, Kathleen F.; Marinko, Justin T.; Hampton, Cheri M.; Ke, Zunlong; Hadziselimovic, Arina; Schlebach, Jonathan P.; Law, Cheryl L.; Li, Jun; Wright, Elizabeth R.; Sanders, Charles R.; Ohi, Melanie D.

    2017-01-01

    Peripheral myelin protein 22 (PMP22) is highly expressed in myelinating Schwann cells of the peripheral nervous system. PMP22 genetic alterations cause the most common forms of Charcot-Marie-Tooth disease (CMTD), which is characterized by severe dysmyelination in the peripheral nerves. However, the functions of PMP22 in Schwann cell membranes remain unclear. We demonstrate that reconstitution of purified PMP22 into lipid vesicles results in the formation of compressed and cylindrically wrapped protein-lipid vesicles that share common organizational traits with compact myelin of peripheral nerves in vivo. The formation of these myelin-like assemblies depends on the lipid-to-PMP22 ratio, as well as on the PMP22 extracellular loops. Formation of the myelin-like assemblies is disrupted by a CMTD-causing mutation. This study provides both a biochemical assay for PMP22 function and evidence that PMP22 directly contributes to membrane organization in compact myelin. PMID:28695207

  10. Peripheral Arterial Disease Can Be a Killer

    Science.gov (United States)

    ... Bar Home Current Issue Past Issues Special Section Peripheral Arterial Disease Can Be a Killer Past Issues / ... Color changes in skin, paleness, or blueness Lower temperature in one leg compared to the other leg ...

  11. Management of peripheral facial nerve palsy

    OpenAIRE

    Finsterer, Josef

    2008-01-01

    Peripheral facial nerve palsy (FNP) may (secondary FNP) or may not have a detectable cause (Bell?s palsy). Three quarters of peripheral FNP are primary and one quarter secondary. The most prevalent causes of secondary FNP are systemic viral infections, trauma, surgery, diabetes, local infections, tumor, immunological disorders, or drugs. The diagnosis of FNP relies upon the presence of typical symptoms and signs, blood chemical investigations, cerebro-spinal-fluid-investigations, X-ray of the...

  12. Atherectomy in Peripheral Artery Disease: A Review.

    Science.gov (United States)

    Bhat, Tariq M; Afari, Maxwell E; Garcia, Lawrence A

    2017-04-01

    Peripheral arterial disease (PAD) is a clinical manifestation of systemic atherosclerosis and is associated with significant morbidity and mortality. The physiological force and shear stress from angioplasty and stenting have made PAD treatment challenging. Atherectomy devices have continued to emerge as a major therapy in the management of peripheral vascular disease. This article presents a review of the current literature for the atherectomy devices used in PAD.

  13. Passive Scalar Evolution in Peripheral Region

    OpenAIRE

    Lebedev, V. V.; Turitsyn, K. S.

    2003-01-01

    We consider evolution of a passive scalar (concentration of pollutants or temperature) in a chaotic (turbulent) flow. A universal asymptotic behavior of the passive scalar decay (homogenization) related to peripheral regions (near walls) is established. The passive scalar moments and its pair correlation function in the peripheral region are analyzed. A special case investigated in our paper is the passive scalar decay along a pipe.

  14. Peripheral Circulatory Features during High-Frequency Jet Ventilation

    Directory of Open Access Journals (Sweden)

    M. B. Kontorovich

    2010-01-01

    Full Text Available The paper gives the results of a study of peripheral circulatory features during high-frequency jet ventilation (HFJV. The main specific features of peripheral circulation and oxygen transport during HFJV are formulated on the basis of a study of cardiac output (impedance cardiography, peripheral vascular resistance, peripheral vascular blood filling (photoplethysmogram analysis, adaptive peripheral blood flow reactions (spectral analysis of peripheral vascular pulsation. HFJV gives rise to the peculiar pattern of peripheral hemodynamics and tissue gas exchange, which is characterized by higher oxygen uptake without a decrease in mixed venous blood saturation, with normal extraction coefficient and preserved low peripheral vascular resistance. During HFJV, unlike traditional ventilation, the main peripheral hemodynamic feature is the increased capillary bed blood volume caused by the blood flow involvement of reserve capillaries under control of volume (parasympathetic regulation of adaptive peripheral hemodynamic reactions. Key words: high-frequency jet ventilation, oxygen transport, peripheral hemodynamics.

  15. Mount Saint Helens, Washington, USA, SRTM Perspective: Shaded Relief and Colored Height

    Science.gov (United States)

    2004-01-01

    Mount Saint Helens is a prime example of how Earth's topographic form can greatly change even within our lifetimes. The mountain is one of several prominent volcanoes of the Cascade Range that stretches from British Columbia, Canada, southward through Washington, Oregon, and into northern California. Mount Adams (left background) and Mount Hood (right background) are also seen in this view, which was created entirely from elevation data produced by the Shuttle Radar Topography Mission. Prior to 1980, Mount Saint Helens had a shape roughly similar to other Cascade peaks, a tall, bold, irregular conic form that rose to 2950 meters (9677 feet). However, the explosive eruption of May 18, 1980, caused the upper 400 meters (1300 feet) of the mountain to collapse, slide, and spread northward, covering much of the adjacent terrain (lower left), leaving a crater atop the greatly shortened mountain. Subsequent eruptions built a volcanic dome within the crater, and the high rainfall of this area lead to substantial erosion of the poorly consolidated landslide material. Eruptions at Mount Saint Helens subsided in 1986, but renewed volcanic activity here and at other Cascade volcanoes is inevitable. Predicting such eruptions still presents challenges, but migration of magma within these volcanoes often produces distinctive seismic activity and minor but measurable topographic changes that can give warning of a potential eruption. Three visualization methods were combined to produce this image: shading of topographic slopes, color coding of topographic height, and then projection into a perspective view. The shade image was derived by computing topographic slope in the northeast-southwest (left to right) direction, so that northeast slopes appear bright and southwest slopes appear dark. Color coding is directly related to topographic height, with green at the lower elevations, rising through yellow and tan, to white at the highest elevations. The perspective view simulates the

  16. Mini-review: Far peripheral vision.

    Science.gov (United States)

    Simpson, Michael J

    2017-11-01

    The region of far peripheral vision, beyond 60 degrees of visual angle, is important to the evaluation of peripheral dark shadows (negative dysphotopsia) seen by some intraocular lens (IOL) patients. Theoretical calculations show that the limited diameter of an IOL affects ray paths at large angles, leading to a dimming of the main image for small pupils, and to peripheral illumination by light bypassing the IOL for larger pupils. These effects are rarely bothersome, and cataract surgery is highly successful, but there is a need to improve the characterization of far peripheral vision, for both pseudophakic and phakic eyes. Perimetry is the main quantitative test, but the purpose is to evaluate pathologies rather than characterize vision (and object and image regions are no longer uniquely related in the pseudophakic eye). The maximum visual angle is approximately 105 0 , but there is limited information about variations with age, race, or refractive error (in case there is an unexpected link with the development of myopia), or about how clear cornea, iris location, and the limiting retina are related. Also, the detection of peripheral motion is widely recognized to be important, yet rarely evaluated. Overall, people rarely complain specifically about this visual region, but with "normal" vision including an IOL for >5% of people, and increasing interest in virtual reality and augmented reality, there are new reasons to characterize peripheral vision more completely. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Treatment of painful diabetic peripheral neuropathy.

    Science.gov (United States)

    Rosenberg, Casandra J; Watson, James C

    2015-02-01

    Painful diabetic peripheral neuropathy impairs quality of life and can be difficult to treat. To discuss current treatment recommendations for painful diabetic peripheral neuropathy. Literature review. Systematic review of the literature discussing treatment of painful diabetic peripheral neuropathy. Existing treatment guidelines were studied and compared. Painful diabetic peripheral neuropathy occurs in about one in six people with diabetes. This condition impairs quality of life and increases healthcare costs. Treatment recommendations exist, but individual patient therapy can require a trial-and-error approach. Many treatment options have adjuvant benefits or side effects which should be considered prior to initiating therapy. Often, a combination of treatment modalities with various mechanisms of action is required for adequate pain control. Adequate medication titration and a reasonable trial period should be allowed. The treatment of painful diabetic peripheral neuropathy can be challenging, but effective management can improve patient's quality of life. Painful diabetic peripheral neuropathy impairs quality of life and can be difficult to treat. Many treatment options have adjuvant benefits or side effects which should be considered prior to initiating therapy. Often, a combination of treatment modalities with various mechanisms of action is required for adequate pain control. © The International Society for Prosthetics and Orthotics 2014.

  18. Vascular access in neonatology: peripherally inserted central catheter and peripheral venous catheter

    Directory of Open Access Journals (Sweden)

    Marcia Lienemann

    2014-04-01

    The objective of this paper is to present aspects of peripherally inserted central catheter and peripheral venous catheter, highlighting important points in choosing the type of access. For the passage of peripherally inserted central catheter is previously performing specific course necessary, while the primary indication occurs when it is necessary to access the patient's stay for a long period of time. Whereas peripheral venipuncture is the most appropriate in cases of needing an IV line quickly and safely, for the administration of fluids, blood collection, blood transfusion and other.

  19. Liberating the Temple Mount: apocalyptic tendencies among Jewish temple activists

    Directory of Open Access Journals (Sweden)

    Maria Leppäkari

    2006-01-01

    Full Text Available Every now and then instances of violence are played out at the Temple Mount area in Jerusalem, also known as the Haram-esh-sharif. Some of the cases are referred to as results of the so-called ‘Jerusalem syndrome’, incidents when individuals’ manifestations of pre-existing psychopathology culminate in violent actions. Israeli psychiatrists and others have treated such incidents as examples of when peoples’ expectations of a heavenly Jerusalem collide with the very earthly reality in the city. For some people, such encounters may create anxiety that may threaten the victim’s very sanity. In such situations, an apocalyptic mission may become the only way for them to cope with the situation at hand. But the Temple Mount does not only attract lone-acting individuals, it also attracts organized groups who refer to the very spot as an important identity marker. In this article, the author draws on her field research material and interviews with Jewish Third Temple activists in Jerusalem collected on and off between 1998 and 2004. Here Yehuda Etzion’s, Gershon Salomon’s and Yoel Lerner’s theology and activities are studied in light of apocalyptic representations, and how these are expressed in relation to religious longing for the Third Temple in the light of the Gaza withdrawal. Not all those who are engaged in endtime scenarios act upon their visions. In Jerusalem, there have been, and still are, several religious-political groups that more or less ritually perambulate the Temple Mount area.

  20. Acoustic methods for high-throughput protein crystal mounting at next-generation macromolecular crystallographic beamlines.

    Science.gov (United States)

    Roessler, Christian G; Kuczewski, Anthony; Stearns, Richard; Ellson, Richard; Olechno, Joseph; Orville, Allen M; Allaire, Marc; Soares, Alexei S; Héroux, Annie

    2013-09-01

    To take full advantage of advanced data collection techniques and high beam flux at next-generation macromolecular crystallography beamlines, rapid and reliable methods will be needed to mount and align many samples per second. One approach is to use an acoustic ejector to eject crystal-containing droplets onto a solid X-ray transparent surface, which can then be positioned and rotated for data collection. Proof-of-concept experiments were conducted at the National Synchrotron Light Source on thermolysin crystals acoustically ejected onto a polyimide `conveyor belt'. Small wedges of data were collected on each crystal, and a complete dataset was assembled from a well diffracting subset of these crystals. Future developments and implementation will focus on achieving ejection and translation of single droplets at a rate of over one hundred per second.

  1. Optimized mounting of a polyethylene naphthalate scintillation material in a radiation detector.

    Science.gov (United States)

    Nakamura, Hidehito; Yamada, Tatsuya; Shirakawa, Yoshiyuki; Kitamura, Hisashi; Shidara, Zenichiro; Yokozuka, Takayuki; Nguyen, Philip; Kanayama, Masaya; Takahashi, Sentaro

    2013-10-01

    Polyethylene naphthalate (PEN) has great potential as a scintillation material for radiation detection. Here the optimum mounting conditions to maximize the light collection efficiency from PEN in a radiation detector are discussed. To this end, we have determined light yields emitted from irradiated PEN for various optical couplings between the substrate and the photodetector, and for various substrate surface treatments. The results demonstrate that light extraction from PEN is more sensitive to the optical couplings due to its high refractive index. We also assessed the extent of radioactive impurities in PEN as background sources and found that the impurities are equivalent to the environmental background level. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. The role of mycorrhizal fungi and microsites in primary succession on Mount St. Helens.

    Science.gov (United States)

    Titus, J; Del Moral, R

    1998-03-01

    This study was designed to examine the role of vesicular-arbuscular mycorrhizae (VAM) and microsites on the growth of pioneer species. Flat, rill, near-rock, and dead lupine microsites were created in plots in barren areas of the Pumice Plain of Mount St. Helens. VAM propagules were added to the soil in half of the plots. Six pioneer species were planted into both VAM and non-VAM inoculated microsites. Plants in dead lupine microsites were greater in biomass than those in flat, rill, and near-rock microsites. Significant effects of VAM on plant biomass did not occur. Microsites continue to be important to plant colonization on the Pumice Plain, but VAM do not yet appear to play an important role. This may be due to limited nutrient availability and the facultatively mycotrophic nature of the colonizing plant species. It is unlikely that VAM play an important role in successional processes in newly emplaced nutrient-poor surfaces.

  3. Balanced and servo control surfaces

    Science.gov (United States)

    1930-01-01

    Many reports on various control systems are available, but the results cannot be generally applied since the effect of particular changes of surface-form and mounting are subject to variations depending upon airfoil section and influences of airplane layout. This report presents a simple analysis of several control systems in more general use. Elevators, ailerons, and rudders are all discussed.

  4. Evaluation of HOPG mounting possibilities for multiplexing spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Groitl, Felix, E-mail: felix.groitl@psi.ch [Laboratory for Quantum Magnetism, École Polytechnique Fédérale de Lausanne, 1015 Lausanne (Switzerland); Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, 5232 Villigen (Switzerland); Bartkowiak, Marek [Laboratory for Scientific Developments and Novel Materials, Paul Scherrer Institut, 5232 Villigen (Switzerland); Bergmann, Ryan M. [Division Large Research Facilities, Paul Scherrer Institut, 5232 Villigen (Switzerland); Birk, Jonas Okkels [Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, 5232 Villigen (Switzerland); Department of Physics, Technical University of Denmark (DTU), 2800 Kgs. Lyngby (Denmark); Markó, Márton [Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, 5232 Villigen (Switzerland); Wigner Research Centre for Physics, Neutron Spectroscopy Department, 1525 Budapest (Hungary); Bollhalder, Alex; Graf, Dieter [Laboratory for Scientific Developments and Novel Materials, Paul Scherrer Institut, 5232 Villigen (Switzerland); Niedermayer, Christof [Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, 5232 Villigen (Switzerland); Rüegg, Christian [Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, 5232 Villigen (Switzerland); Department of Quantum Matter Physics, University of Geneva, 1211 Geneva (Switzerland); Rønnow, Henrik M. [Laboratory for Quantum Magnetism, École Polytechnique Fédérale de Lausanne, 1015 Lausanne (Switzerland); Niels Bohr Institute, University of Copenhagen, 2100 Copenhagen (Denmark)

    2017-06-21

    Four different methods for mounting HOPG analyzer crystals on Si holders have been evaluated in the design process of the new multiplexing spectrometer CAMEA. Contrary to neutron optics used in standard spectrometers, the new instrument concept employs a series of analyzer segments behind each other where the neutrons have to pass through the bonding compound of the different analyzer crystals. The different methods, namely screws, shellac, indium soldering and clips, have been evaluated with regards to background, transmission, cooling, activation and handling. The results presented here will give valuable input for future CAMEA-type spectrometers currently planned and designed at various neutron sources.

  5. Cognitive considerations for helmet-mounted display design

    Science.gov (United States)

    Francis, Gregory; Rash, Clarence E.

    2010-04-01

    Helmet-mounted displays (HMDs) are designed as a tool to increase performance. To achieve this, there must be an accurate transfer of information from the HMD to the user. Ideally, an HMD would be designed to accommodate the abilities and limitations of users' cognitive processes. It is not enough for the information (whether visual, auditory, or tactual) to be displayed; the information must be perceived, attended, remembered, and organized in a way that guides appropriate decision-making, judgment, and action. Following a general overview, specific subtopics of cognition, including perception, attention, memory, knowledge, decision-making, and problem solving are explored within the context of HMDs.

  6. Mount Baker lahars and debris flows, ancient, modern, and future

    Science.gov (United States)

    Tucker, David S; Scott, Kevin M.; Grossman, Eric E.; Linneman, Scott

    2014-01-01

    The Middle Fork Nooksack River drains the southwestern slopes of the active Mount Baker stratovolcano in northwest Washington State. The river enters Bellingham Bay at a growing delta 98 km to the west. Various types of debris flows have descended the river, generated by volcano collapse or eruption (lahars), glacial outburst floods, and moraine landslides. Initial deposition of sediment during debris flows occurs on the order of minutes to a few hours. Long-lasting, down-valley transport of sediment, all the way to the delta, occurs over a period of decades, and affects fish habitat, flood risk, gravel mining, and drinking water.

  7. Kinematic mounting systems for NSLS beamlines and experiments

    International Nuclear Information System (INIS)

    Oversluizen, T.; Stoeber, W.; Johnson, E.D.

    1991-01-01

    Methods for kinematically mounting equipment are well established, but applications at synchrotron radiation facilities are subject to constraints not always encountered in more traditional laboratory settings. Independent position adjustment of beamline components can have significant benefits in terms of minimizing time spent aligning, and maximizing time spent acquiring data. In this paper, we use examples taken from beamlines at the NSLS to demonstrate approaches for optimization of the reproducibility, stability, excursion, and set-up time for various situations. From our experience, we extract general principles which we hope will be useful for workers at other synchrotron radiation facilities. 7 refs., 4 figs

  8. Digital cross-mounting: A new opportunity in prosthetic dentistry.

    Science.gov (United States)

    Venezia, Pietro; Torsello, Ferruccio; D'Amato, Salvatore; Cavalcanti, Raffaele

    2017-01-01

    The prosthodontic management of complex rehabilitations requires several stages of treatment including one or more provisional restorations. The design and adjustments of the provisional are made to achieve an optimal functional and esthetic outcome for the patient. However, the adjustments needed are both time and cost consuming. Therefore, once a satisfactory provisional is made, the information should not be lost during the following stages of treatment. The purpose of this clinical case is to illustrate "digital cross-mounting," a procedure used to precisely transfer information from the provisional to the final fixed rehabilitation in a digital workflow.

  9. Active Engine Mounting Control Algorithm Using Neural Network

    Directory of Open Access Journals (Sweden)

    Fadly Jashi Darsivan

    2009-01-01

    Full Text Available This paper proposes the application of neural network as a controller to isolate engine vibration in an active engine mounting system. It has been shown that the NARMA-L2 neurocontroller has the ability to reject disturbances from a plant. The disturbance is assumed to be both impulse and sinusoidal disturbances that are induced by the engine. The performance of the neural network controller is compared with conventional PD and PID controllers tuned using Ziegler-Nichols. From the result simulated the neural network controller has shown better ability to isolate the engine vibration than the conventional controllers.

  10. Cooling performance of a notebook PC mounted with heat spreader

    Energy Technology Data Exchange (ETDEWEB)

    Noh, H.K. [Electronics and Telecommunications Research Institute, Taejeon (Korea); Lim, K.B. [Hanbat National University, Taejeon (Korea); Park, M.H. [Korea Power Engineering Company (Korea)

    2001-06-01

    Parametric study to investigate the cooling performance of a notebook PC mounted with heat spreader has been numerically performed. Two case of air-blowing and air-exhaust at inlet were tested. The cooling effect on parameters such as, inlet velocities in the cases of air-blowing and air-exhaust, materials of heat spreader, and CPU powers were simulated for two cases. Cooling performance in the case of air-blowing was better than the case of air-exhaust. (author). 9 refs., 7 figs., 5 tabs.

  11. Immersive vision assisted remote teleoperation using head mounted displays

    International Nuclear Information System (INIS)

    Vakkapatla, Veerendrababu; Singh, Ashutosh Pratap; Rakesh, V.; Rajagopalan, C.; Murugan, S.; Sai Baba, M.

    2016-01-01

    Handling and inspection of irradiated material is inevitable in nuclear industry. Hot cells are shielded radiation containment chambers equipped with master slave manipulators that facilitates remote handling. The existing methods using viewing windows and cameras for viewing the contents of hot cell to manipulate the radioactive elements have problems such as optical distortion, limited distance teleoperation, limited field of view that lead to inefficient operation. This paper presents a method of achieving immersive teleoperation to operate the master slave manipulator in hot cells by exploiting the advanced tracking and display capabilities of head mounted display devices. (author)

  12. The misalignment angle in vessel-mounted ADCP

    Directory of Open Access Journals (Sweden)

    Robert Osinski

    2000-09-01

    Full Text Available A description of the misalignment angle and the consequences if it occurs is given. It is shown that because of gyrocompass errors, the misalignment angle error a has to be computed for each cruise. A simple method of calibrating the acoustic Doppler current profiler (ADCP mounted on a vessel has been devised by fitting the cosinusoidal function. This is a post-processing method, suitable for calibrating previously collected data. Nevertheless, because of ADCP's constructional peculiarities, the procedure must be repeated for each cruise.

  13. Evaluation of HOPG mounting possibilities for multiplexing spectrometers

    International Nuclear Information System (INIS)

    Groitl, Felix; Bartkowiak, Marek; Bergmann, Ryan M.; Birk, Jonas Okkels; Markó, Márton; Bollhalder, Alex; Graf, Dieter; Niedermayer, Christof; Rüegg, Christian; Rønnow, Henrik M.

    2017-01-01

    Four different methods for mounting HOPG analyzer crystals on Si holders have been evaluated in the design process of the new multiplexing spectrometer CAMEA. Contrary to neutron optics used in standard spectrometers, the new instrument concept employs a series of analyzer segments behind each other where the neutrons have to pass through the bonding compound of the different analyzer crystals. The different methods, namely screws, shellac, indium soldering and clips, have been evaluated with regards to background, transmission, cooling, activation and handling. The results presented here will give valuable input for future CAMEA-type spectrometers currently planned and designed at various neutron sources.

  14. Experimental investigation on flow and heat transfer for cooling flush-mounted ribbons in a channel: Application of an EHD active enhancement method

    Directory of Open Access Journals (Sweden)

    Alami Nia Amin

    2016-01-01

    Full Text Available In the present study, the heat transfer enhancement of a bundle of flush-mounted ribbons placed on the floor of a rectangular duct was investigated experimentally. The flush-mounted ribbons act as heat sources and the cooling happens with air. The air flow was two-dimensional, steady, viscous and incompressible under either laminar (500 ≤ ReDh < 2000 and turbulent (2000 ≤ Re Dh ≤ 4500 conditions. The hydrodynamics and heat transfer behavior of the air flow was studied by means of an active method with application of corona wind. The state of the art of this work revolves around an experimental investigation of an EHD1 active method and heat transfer enhancement from the surfaces of the flush- mounted ribbons. Due to the intricacies of the required experiment, a special apparatus needed to be designed and constructed.

  15. The Mantle and Basalt-Crust Interaction Below the Mount Taylor Volcanic Field, New Mexico

    Science.gov (United States)

    Schrader, Christian M.; Crumpler, Larry S.; Schmidt, Marick E.

    2010-01-01

    The Mount Taylor Volcanic Field (MTVF) lies on the Jemez Lineament on the southeastern margin of the Colorado Plateau. The field is centered on the Mt. Taylor composite volcano and includes Mesa Chivato to the NE and Grants Ridge to the WSW. MTVF magmatism spans approximately 3.8-1.5 Ma (K-Ar). Magmas are dominantly alkaline with mafic compositions ranging from basanite to hy-basalt and felsic compositions ranging from ne-trachyte to rhyolite. We are investigating the state of the mantle and the spatial and temporal variation in basalt-crustal interaction below the MTVF by examining mantle xenoliths and basalts in the context of new mapping and future Ar-Ar dating. The earliest dated magmatism in the field is a basanite flow south of Mt. Taylor. Mantle xenolith-bearing alkali basalts and basanites occur on Mesa Chivato and in the region of Mt. Taylor, though most basalts are peripheral to the main cone. Xenolith-bearing magmatism persists at least into the early stages of conebuilding. Preliminary examination of the mantle xenolith suite suggests it is dominantly lherzolitic but contains likely examples of both melt-depleted (harzburgitic) and melt-enriched (clinopyroxenitic) mantle. There are aphyric and crystal-poor hawaiites, some of which are hy-normative, on and near Mt. Taylor, but many of the more evolved MTVF basalts show evidence of complex histories. Mt. Taylor basalts higher in the cone-building sequence contain >40% zoned plagioclase pheno- and megacrysts. Other basalts peripheral to Mt. Taylor and at Grants Ridge contain clinopyroxene and plagioclase megacrysts and cumulate-textured xenoliths, suggesting they interacted with lower crustal cumulates. Among the questions we are addressing: What was the chemical and thermal state of the mantle recorded by the basaltic suites and xenoliths and how did it change with time? Are multiple parental basalts (Si-saturated vs. undersaturated) represented and, if so, what changes in the mantle or in the tectonic

  16. Comparison between skin-mounted fiducials and bone-implanted fiducials for image-guided neurosurgery

    Science.gov (United States)

    Rost, Jennifer; Harris, Steven S.; Stefansic, James D.; Sillay, Karl; Galloway, Robert L., Jr.

    2004-05-01

    Point-based registration for image-guided neurosurgery has become the industry standard. While the use of intrinsic points is appealing because of its retrospective nature, affixing extrinsic objects to the head prior to scanning has been demonstrated to provide much more accurate registrations. Points of reference between image space and physical space are called fiducials. The extrinsic objects which generate those points are fiducial markers. The markers can be broken down into two classifications: skin-mounted and bone-implanted. Each has distinct advantages and disadvantages. Skin-mounted fiducials require simply sticking them on the patient in locations suggested by the manufacturer, however, they can move with tractions placed on the skin, fall off and perhaps the most dangerous problem, they can be replaced by the patient. Bone implanted markers being rigidly affixed to the skull do not present such problems. However, a minor surgical intervention (analogous to dental work) must be performed to implant the markers prior to surgery. Therefore marker type and use has become a decision point for image-guided surgery. We have performed a series of experiments in an attempt to better quantify aspects of the two types of markers so that better informed decisions can be made. We have created a phantom composed of a full-size plastic skull [Wards Scientific Supply] with a 500 ml bag of saline placed in the brain cavity. The skull was then sealed. A skin mimicking material, DragonSkinTM [SmoothOn Company] was painted onto the surface and allowed to dry. Skin mounted fiducials [Medtronic-SNT] and bone-implanted markers [Z-Kat]were placed on the phantom. In addition, three additional bone-implanted markers were placed (two on the base of the skull and one in the eye socket for use as targets). The markers were imaged in CT and 4 MRI sequences (T1-weighted, T2 weighted, SPGR, and a functional series.) The markers were also located in physical space using an Optotrak

  17. Large Extremity Peripheral Nerve Repair

    Science.gov (United States)

    2016-12-01

    These antimicrobial peptides are implicated in the resistance of epithelial surfaces to microbial colonisation and have been shown to be upregulated...be equivalent to standard autograft repair in rodent models. Outcomes have now been validated in a large animal (swine) model with 5 cm ulnar nerve...Goals of the Project Task 1– Determine mechanical properties, seal strength and resistance to biodegradation of candidate photochemical nerve wrap

  18. Facilitation of the main generator source of earthworm muscle contraction by a peripheral neuron

    Directory of Open Access Journals (Sweden)

    Chang Y.C.

    1998-01-01

    Full Text Available A constant facilitation of responses evoked in the earthworm muscle contraction generator neurons by responses evoked in the neurons of its peripheral nervous system was demonstrated. It is based on the proposal that these two responses are bifurcations of an afferent response evoked by the same peripheral mechanical stimulus but converging again on this central neuron. A single-peaked generator response without facilitation was demonstrated by sectioning the afferent route of the peripheral facilitatory modulatory response, or conditioning response (CR. The multipeaked response could be restored by restimulating the sectioned modulatory neuron with an intracellular substitutive conditioning stimulus (SCS. These multi-peaked responses were proposed to be the result of reverberating the original single peaked unconditioned response (UR through a parallel (P neuronal circuit which receives the facilitation of the peripheral modulatory neuron. This peripheral modulatory neuron was named "Peri-Kästchen" (PK neuron because it has about 20 peripheral processes distributed on the surface of a Kästchen of longitudinal muscle cells on the body wall of this preparation as revealed by the Lucifer Yellow-CH-filling method.

  19. Preparation of Samples for Leaf Architecture Studies, A Method for Mounting Cleared Leaves

    Directory of Open Access Journals (Sweden)

    Alejandra Vasco

    2014-09-01

    Full Text Available Premise of the study: Several recent waves of interest in leaf architecture have shown an expanding range of approaches and applications across a number of disciplines. Despite this increased interest, examination of existing archives of cleared and mounted leaves shows that current methods for mounting, in particular, yield unsatisfactory results and deterioration of samples over relatively short periods. Although techniques for clearing and staining leaves are numerous, published techniques for mounting leaves are scarce. Methods and Results: Here we present a complete protocol and recommendations for clearing, staining, and imaging leaves, and, most importantly, a method to permanently mount cleared leaves. Conclusions: The mounting protocol is faster than other methods, inexpensive, and straightforward; moreover, it yields clear and permanent samples that can easily be imaged, scanned, and stored. Specimens mounted with this method preserve well, with leaves that were mounted more than 35 years ago showing no signs of bubbling or discoloration.

  20. Preparation of samples for leaf architecture studies, a method for mounting cleared leaves.

    Science.gov (United States)

    Vasco, Alejandra; Thadeo, Marcela; Conover, Margaret; Daly, Douglas C

    2014-09-01

    Several recent waves of interest in leaf architecture have shown an expanding range of approaches and applications across a number of disciplines. Despite this increased interest, examination of existing archives of cleared and mounted leaves shows that current methods for mounting, in particular, yield unsatisfactory results and deterioration of samples over relatively short periods. Although techniques for clearing and staining leaves are numerous, published techniques for mounting leaves are scarce. • Here we present a complete protocol and recommendations for clearing, staining, and imaging leaves, and, most importantly, a method to permanently mount cleared leaves. • The mounting protocol is faster than other methods, inexpensive, and straightforward; moreover, it yields clear and permanent samples that can easily be imaged, scanned, and stored. Specimens mounted with this method preserve well, with leaves that were mounted more than 35 years ago showing no signs of bubbling or discoloration.

  1. Preparation of samples for leaf architecture studies, a method for mounting cleared leaves1

    Science.gov (United States)

    Vasco, Alejandra; Thadeo, Marcela; Conover, Margaret; Daly, Douglas C.

    2014-01-01

    • Premise of the study: Several recent waves of interest in leaf architecture have shown an expanding range of approaches and applications across a number of disciplines. Despite this increased interest, examination of existing archives of cleared and mounted leaves shows that current methods for mounting, in particular, yield unsatisfactory results and deterioration of samples over relatively short periods. Although techniques for clearing and staining leaves are numerous, published techniques for mounting leaves are scarce. • Methods and Results: Here we present a complete protocol and recommendations for clearing, staining, and imaging leaves, and, most importantly, a method to permanently mount cleared leaves. • Conclusions: The mounting protocol is faster than other methods, inexpensive, and straightforward; moreover, it yields clear and permanent samples that can easily be imaged, scanned, and stored. Specimens mounted with this method preserve well, with leaves that were mounted more than 35 years ago showing no signs of bubbling or discoloration. PMID:25225627

  2. Mounting Systems for Structural Members, Fastening Assemblies Thereof, and Vibration Isolation Systems Including the Same

    Science.gov (United States)

    Young, Ken (Inventor); Hindle, Timothy (Inventor); Barber, Tim Daniel (Inventor)

    2016-01-01

    Mounting systems for structural members, fastening assemblies thereof, and vibration isolation systems including the same are provided. Mounting systems comprise a pair of mounting brackets, each clamped against a fastening assembly forming a mounting assembly. Fastening assemblies comprise a spherical rod end comprising a spherical member having a through opening and an integrally threaded shaft, first and second seating members on opposite sides of the spherical member and each having a through opening that is substantially coaxial with the spherical member through opening, and a partially threaded fastener that threadably engages each mounting bracket forming the mounting assembly. Structural members have axial end portions, each releasably coupled to a mounting bracket by the integrally threaded shaft. Axial end portions are threaded in opposite directions for permitting structural member rotation to adjust a length thereof to a substantially zero strain position. Structural members may be vibration isolator struts in vibration isolation systems.

  3. Case report of a patient with peripheral facial nerve palsy

    OpenAIRE

    Rysová, Jana

    2013-01-01

    Title of bachelor's thesis: Case report of a patient with peripheral facial nerve palsy Summary: Teoretical part of bachelor's thesis contains theoretical foundation of peripheral facial nerve palsy. Practical part of bachelor's thesis contains physiotherapeutic case report of patient with peripheral facial nerve palsy. Key words: peripheral facial nerve palsy, casuistry, rehabilitation

  4. A Vehicle-mounted Crop Detector with Wireless Sensor Network

    Directory of Open Access Journals (Sweden)

    Zhenjiang ZHONG

    2014-03-01

    Full Text Available In order to detect crop chlorophyll content in real-time, a new vehicle-mounted detector for measuring crop canopy spectral characteristics was developed. It was designed to work as a wireless sensor network with several optical sensor nodes and one control unit. All the optical sensor nodes were mounted on an on-board mechanical structure so that they could collect the canopy spectral data while in mobile condition. Each optical sensor node was designed to contain four optical channels, which allowed it work at the wavebands of 550, 650, 766 and 850 nm. The control unit included a PDA (Personal Digital Assistant device with a ZigBee wireless network coordinator and a GPRS module. It was used to receive, display, store all the data sent from optical sensor nodes and send data to the server through GPRS module. The calibration tests verified the stability of the wireless network and the measurement precision of the sensors. Both stationary and moving field experiments were also conducted in a winter wheat experimental field. Results showed that the correlation between chlorophyll content and vegetation index had high significance with the highest R2 of 0.6824. Those results showed the potential of the detector for field application.

  5. Qualification of engine-mounted components due to operational vibration

    International Nuclear Information System (INIS)

    Lee, B.J.; Bayat, A.

    1994-01-01

    The Emergency Diesel Generator (EDG) in a Nuclear Power Plant is considered to be an essential component of the plant for its safe operation. Failures of auxiliary components directly mounted on the EDG creates costly repairs, and compromises the engine's availability and reliability. Although IEEE-323 and Section III of the ASME code require addressing of safety-related components due to mechanically induced vibration, very few guidelines exist in the nuclear industry to show how this may be accounted for. Most engine vendors rely on the empirical experience data as the basis of their evaluation for vibration. Upgrade of engine controls, addition of monitoring components and other engine modifications require design and installation of new mechanical and electrical components to be mounted directly on the engine. This necessitates the evaluation of such components for engine-induced vibration which is considered to be one of the most severe design parameters. This paper presents a methodology to evaluate three categories of components; structural, mechanical, and electrical under engine vibration. The discussion for the characteristics and manipulation of engine vibration profile to be used for each component evaluation is also given. In addition, the suitability of analytical verses testing approaches is discussed for each category. An example application of the methodology is presented for a typical EDG which is currently undergoing major controls upgrade and monitoring modification

  6. Sensor 17 Thermal Isolation Mounting Structure (TIMS) Design Improvements

    Energy Technology Data Exchange (ETDEWEB)

    Enstrom, K. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-09-04

    The SENSOR 17 thermographic camera weighs approximately 0.5lbs, has a fundamental mode of 167 Hz, and experiences 0.75W of heat leakage in through the TIMS. The configuration, shown in Figure 1, is comprised of four 300 Series SST washers paired in tandem with P.E.I (Ultem 100) washers. The SENSOR 17 sensor is mounted to a 300 series stainless plate with A-shaped arms. The Plate can be assumed to be at ambient temperatures (≈293K) and the I.R. Mount needs to be cooled to 45K. It is attached to the tip of a cryocooler by a ‘cold strap’ and is assumed to be at the temperature of the cold-strap (≈45K). During flights SENSOR 17 experiences excitations at frequencies centered around 10-30Hz, 60Hz, and 120Hz from the aircraft flight environment. The temporal progression described below depicts the 1st Modal shape at the systems resonant frequency. This simulation indicates Modal articulation will cause a pitch rate of the camera with respect to the body axis of the airplane. This articulation shows up as flutter in the camera.

  7. Destruction and management of Mount Kenya`s forests

    Energy Technology Data Exchange (ETDEWEB)

    Bussmann, R.W. [Bayreuth Univ. (Germany). Fakultaet fuer Biologie, Chemie und Geowissenschaften

    1996-08-01

    This article presents data on the destruction of the montane forests on Mount Kenya. The material was obtained during field-work for a phytosociological study in 1992-1994. Special emphasis was given to the observation of regeneration patterns and succession cycles within the different forest communities, with regard to the impact of humans and big game. Although private tree planting is reducing the fuelwood deficit in Kenya, large parts of the 200 000 ha of Mount Kenya`s forests - the largest natural-forest area in the country - are heavily impacted by among other things illegal activities. The wet camphor forests of the south and southeast mountain slopes are being destroyed at an alarming speed, by large-scale selective logging of Ocotea usambarensis and marihuana cultivation. The drier Juniperus procera are also logged, but are even more endangered by the new settlement schemes. The large elephant population does not affect forest regeneration; whereas browsing and chaffing by buffaloes inhibits regeneration of the dry forests, and damages many trees. Suggestions are presented for better management of the forest resources. 12 refs, 1 fig

  8. Design features of SMART for barge mounted application

    International Nuclear Information System (INIS)

    Doo-Jeong Lee; Ju-Hyeon Yoon; Ju-Pyung Kim; Jong-In Kim; Moon-Hee Chang

    2000-01-01

    SMART is an integral reactor of 330 MWt capacity with passive safety features being developed for a wide range of applications including the barge mounted co-generation plant. Its design strives to combine the firmly-established commercial reactor design with new advanced technologies. Thus the use of the industry proven KOFA (Korea Optimized Fuel Assembly) based nuclear fuels is pursued while such radically new technologies as self-pressurizing pressurizer, helical once-through steam generators, and advanced control concepts are being developed. The safety of SMART centers around enhancing the inherent safety characteristics of the reactor and salient features include low core power density, integral arrangement to eliminate large break loss of coolant accident, etc. The progression of emergency situations into accidents is prevented with a number of advanced engineered safety features such as Passive Residual Heat Removal System, Passive Emergency Core Cooling System, Safeguard Vessel, Passive Containment Over-pressure Protection. This paper presents the status of current SMART development, characteristics of SMART safety systems and the possibility of SMART application to barge mounted environment. (author)

  9. Bottom-mounted control rod drive mechanism for KJRR

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Haeng; Kim, Sanghaun; Yoo, Yeon-Sik, E-mail: yooys@kaeri.re.kr; Cho, Yeong-Garp; Huh, Hyung; Lee, Hyokwang; Sun, Jong-Oh; Ryu, Jeong-Soo

    2016-04-15

    Highlights: • The basic design features and characteristics of the KJRR BMCRDM are described. • The similarities and differences of some research reactor CRDMs are compared. • The current status of the design and development of the CRDM is described. • The future plan of the qualification tests of the CRDM is summarized. - Abstract: The KIJANG research reactor (KJRR), which is currently being designed by Korea Atomic Energy Research Institute, is a pool type research reactor with 15 MW of thermal power. Contrary to the top-mounted control rod drive mechanism (CRDM), the main drive mechanism of the KJRR CRDM is located in a reactivity control mechanism room under the reactor pool bottom. Recently, we accomplished the design and development of a prototype CRDM. In this paper, we introduce the basic design concept of the bottom-mounted CRDM for KJRR, and compare the similarities and differences of some research reactor CRDMs. The current status of the prototype CRDM development based on a finite element analysis and experimental verification, and the future plan of the CRDM qualification tests, are both described.

  10. Beating-heart registration for organ-mounted robots.

    Science.gov (United States)

    Wood, Nathan A; Schwartzman, David; Passineau, Michael J; Moraca, Robert J; Zenati, Marco A; Riviere, Cameron N

    2018-03-06

    Organ-mounted robots address the problem of beating-heart surgery by adhering to the heart, passively providing a platform that approaches zero relative motion. Because of the quasi-periodic deformation of the heart due to heartbeat and respiration, registration must address not only spatial registration but also temporal registration. Motion data were collected in the porcine model in vivo (N = 6). Fourier series models of heart motion were developed. By comparing registrations generated using an iterative closest-point approach at different phases of respiration, the phase corresponding to minimum registration distance is identified. The spatiotemporal registration technique presented here reduces registration error by an average of 4.2 mm over the 6 trials, in comparison with a more simplistic static registration that merely averages out the physiological motion. An empirical metric for spatiotemporal registration of organ-mounted robots is defined and demonstrated using data from animal models in vivo. Copyright © 2018 John Wiley & Sons, Ltd.

  11. Will Mount Etna erupt before EGU General Assembly 2017?

    Science.gov (United States)

    Aloisi, Marco; Cannavo', Flavio; Palano, Mimmo

    2017-04-01

    Mount Etna has historically recorded a long and very various series of eruptions. The eruptions have mostly shown an episodic character, despite a near continuous supply of magma. In the last years, activity at Mount Etna seems to follow a recurrent pattern characterized by very similar "inflation/paroxysmal events/deflation" dynamic. The paroxysms occurred in December 2015 and May 2016, which involved the "Voragine" crater, can be considered among the most violent observed during the last two decades. These events showed high lava fountains, in the order of hundreds of meters in height, and eruption columns, several kilometres high. A new cycle, characterized by a clear similar inflation of the whole volcano edifice is currently underway. Here, we analyse these recent volcanic cycles and discuss about a) a possible upper bound for the inflation dynamic, above which a paroxysmal event occurs, b) the comparison of the models generating the considered lava fountains and c) a possible time-predictable model of the expected paroxysmal event.

  12. Community Exposure to Lahar Hazards from Mount Rainier, Washington

    Science.gov (United States)

    Wood, Nathan J.; Soulard, Christopher E.

    2009-01-01

    Geologic evidence of past events and inundation modeling of potential events suggest that lahars associated with Mount Rainier, Washington, are significant threats to downstream development. To mitigate potential impacts of future lahars and educate at-risk populations, officials need to understand how communities are vulnerable to these fast-moving debris flows and which individuals and communities may need assistance in preparing for and responding to an event. To support local risk-reduction planning for future Mount Rainier lahars, this study documents the variations among communities in King, Lewis, Pierce, and Thurston Counties in the amount and types of developed land, human populations, economic assets, and critical facilities in a lahar-hazard zone. The lahar-hazard zone in this study is based on the behavior of the Electron Mudflow, a lahar that traveled along the Puyallup River approximately 500 years ago and was due to a slope failure on the west flank of Mount Rainier. This lahar-hazard zone contains 78,049 residents, of which 11 percent are more than 65 years in age, 21 percent do not live in cities or unincorporated towns, and 39 percent of the households are renter occupied. The lahar-hazard zone contains 59,678 employees (4 percent of the four-county labor force) at 3,890 businesses that generate $16 billion in annual sales (4 and 7 percent, respectively, of totals in the four-county area) and tax parcels with a combined total value of $8.8 billion (2 percent of the study-area total). Employees in the lahar-hazard zone are primarily in businesses related to manufacturing, retail trade, transportation and warehousing, wholesale trade, and construction. Key road and rail corridors for the region are in the lahar-hazard zone, which could result in significant indirect economic losses for businesses that rely on these networks, such as the Port of Tacoma. Although occupancy values are not known for each site, the lahar-hazard zone contains numerous

  13. Effects of smoking on activation markers, Fas expression and apoptosis of peripheral blood lymphocytes

    NARCIS (Netherlands)

    Bijl, Marc; Limburg, Piet; Kallenberg, Cees; Horst, G.

    Background Smoking influences numbers and function of peripheral blood lymphocytes (PBL) by a process that is badly understood. We conducted this study to evaluate whether the immune impairment of smoking might be related to changes in the expression or functionality of Fas, a cell surface molecule

  14. Peripheral biomarkers revisited: integrative profiling of peripheral samples for psychiatric research.

    Science.gov (United States)

    Hayashi-Takagi, Akiko; Vawter, Marquis P; Iwamoto, Kazuya

    2014-06-15

    Peripheral samples, such as blood and skin, have been used for decades in psychiatric research as surrogates for central nervous system samples. Although the validity of the data obtained from peripheral samples has been questioned and other state-of-the-art techniques, such as human brain imaging, genomics, and induced pluripotent stem cells, seem to reduce the value of peripheral cells, accumulating evidence has suggested that revisiting peripheral samples is worthwhile. Here, we re-evaluate the utility of peripheral samples and argue that establishing an understanding of the common signaling and biological processes in the brain and peripheral samples is required for the validity of such models. First, we present an overview of the available types of peripheral cells and describe their advantages and disadvantages. We then briefly summarize the main achievements of omics studies, including epigenome, transcriptome, proteome, and metabolome analyses, as well as the main findings of functional cellular assays, the results of which imply that alterations in neurotransmission, metabolism, the cell cycle, and the immune system may be partially responsible for the pathophysiology of major psychiatric disorders such as schizophrenia. Finally, we discuss the future utility of peripheral samples for the development of biomarkers and tailor-made therapies, such as multimodal assays that are used as a battery of disease and trait pathways and that might be potent and complimentary tools for use in psychiatric research. © 2013 Society of Biological Psychiatry Published by Society of Biological Psychiatry All rights reserved.

  15. Peripheral dose outside applicators in electron beams

    International Nuclear Information System (INIS)

    Chow, James C L; Grigorov, Grigor N

    2006-01-01

    The peripheral dose outside the applicators in electron beams was studied using a Varian 21 EX linear accelerator. To measure the peripheral dose profiles and point doses for the applicator, a solid water phantom was used with calibrated Kodak TL films. Peak dose spot was observed in the 4 MeV beam outside the applicator. The peripheral dose peak was very small in the 6 MeV beam and was ignorable at higher energies. Using the 10 x 10 cm 2 cutout and applicator, the dose peak for the 4 MeV beam was about 12 cm away from the field central beam axis (CAX) and the peripheral dose profiles did not change with depths measured at 0.2, 0.5 and 1 cm. The peripheral doses and profiles were further measured by varying the angle of obliquity, cutout and applicator size for the 4 MeV beam. The local peak dose was increased with about 3% per degree angle of obliquity, and was about 1% of the prescribed dose (angle of obliquity equals zero) at 1 cm depth in the phantom using the 10 x 10 cm 2 cutout and applicator. The peak dose position was also shifted 7 mm towards the CAX when the angle of obliquity was increased from 0 to 15 deg. (note)

  16. Receptor localization of steroid hormones and drugs: discoveries through the use of thaw-mount and dry-mount autoradiography

    Directory of Open Access Journals (Sweden)

    Stumpf W.E.

    1998-01-01

    Full Text Available The history of receptor autoradiography, its development and applications, testify to the utility of this histochemical technique for localizing radiolabeled hormones and drugs at cellular and subcellular sites of action in intact tissues. Localization of diffusible compounds has been a challenge that was met through the introduction of the "thaw-mount" and "dry-mount" autoradiographic techniques thirty years ago. With this cellular receptor autoradiography, used alone or combined with other histochemical techniques, sites of specific binding and deposition in vivo and in vitro have been characterized. Numerous discoveries, some reviewed in this article, provided information that led to new concepts and opened new areas of research. As an example, in recent years more than fifty target tissues for vitamin D have been specified, challenging the conventional view about the main biological role of vitamin D. The functions of most of these vitamin D target tissues are unrelated to the regulation of systemic calcium homeostasis, but pertain to the (seasonal regulation of endo- and exocrine secretion, cell proliferation, reproduction, neural, immune and cardiovascular responses, and adaptation to stress. Receptor autoradiography with cellular resolution has become an indispensable tool in drug research and development, since information can be obtained that is difficult or impossible to gain otherwise

  17. MRI features of tuberculosis of peripheral joints

    Energy Technology Data Exchange (ETDEWEB)

    Sawlani, V.; Chandra, T.; Mishra, R.N.; Aggarwal, A.; Jain, U.K.; Gujral, R.B. E-mail: gujralrb@sgpgi.ac.in

    2003-10-01

    The aim of this article is to present the magnetic resonance imaging (MRI) features of peripheral tubercular arthritis. The clinical presentation of peripheral tubercular arthritis is variable and simulates other chronic inflammatory arthritic disorders. MRI is a highly sensitive technique which demonstrates fine anatomical details and identifies the early changes of arthritis, which are not visible on radiographs. The MRI features of tubercular arthritis include synovitis, effusion, central and peripheral erosions, active and chronic pannus, abscess, bone chips and hypo-intense synovium. These imaging features in an appropriate clinical setting may help in the diagnosis of tubercular arthritis. Early diagnosis and treatment can effectively eliminate the long-term morbidity of joints affected by tuberculosis.

  18. MRI features of tuberculosis of peripheral joints

    International Nuclear Information System (INIS)

    Sawlani, V.; Chandra, T.; Mishra, R.N.; Aggarwal, A.; Jain, U.K.; Gujral, R.B.

    2003-01-01

    The aim of this article is to present the magnetic resonance imaging (MRI) features of peripheral tubercular arthritis. The clinical presentation of peripheral tubercular arthritis is variable and simulates other chronic inflammatory arthritic disorders. MRI is a highly sensitive technique which demonstrates fine anatomical details and identifies the early changes of arthritis, which are not visible on radiographs. The MRI features of tubercular arthritis include synovitis, effusion, central and peripheral erosions, active and chronic pannus, abscess, bone chips and hypo-intense synovium. These imaging features in an appropriate clinical setting may help in the diagnosis of tubercular arthritis. Early diagnosis and treatment can effectively eliminate the long-term morbidity of joints affected by tuberculosis

  19. Comprehensive management of presbycusis: central and peripheral.

    Science.gov (United States)

    Parham, Kourosh; Lin, Frank R; Coelho, Daniel H; Sataloff, Robert T; Gates, George A

    2013-04-01

    The prevailing otolaryngologic approach to treatment of age-related hearing loss (ARHL), presbycusis, emphasizes compensation of peripheral functional deficits (ie, hearing aids and cochlear implants). This approach does not address adequately the needs of the geriatric population, 1 in 5 of whom is expected to consist of the "old old" in the coming decades. Aging affects both the peripheral and central auditory systems, and disorders of executive function become more prevalent with advancing age. Growing evidence supports an association between age-related hearing loss and cognitive decline. Thus, to facilitate optimal functional capacity in our geriatric patients, a more comprehensive management strategy of ARHL is needed. Diagnostic evaluation should go beyond standard audiometric testing and include measures of central auditory function, including dichotic tasks and speech-in-noise testing. Treatment should include not only appropriate means of peripheral compensation but also auditory rehabilitative training and counseling.

  20. [Peripheral retinal degenerations--treatment recommendations].

    Science.gov (United States)

    Joussen, A M; Kirchhof, B

    2004-10-01

    This report reviews the clinical appearance of degenerative diseases of the peripheral retina in relationship to the risk of developing a rhegmatogenous retinal detachment. We present recommendations for preventive treatment in eyes at increased risk of developing retinal detachment. Retinal degenerations are common lesions involving the peripheral retina but most of them are clinically insignificant. Lattice degeneration, degenerative retinoschisis, cystic retinal tufts, and very rarely zonular traction tufts can result in rhegmatogenous retinal detachment. Therefore, these lesions have been considered for prophylactic treatment; however, adequate studies have not been performed to date. Most of the peripheral retinal degenerations may not require treatment except in rare, high-risk situations. According to current knowledge there is no higher incidence of secondary pucker or other side effects after laser coagulation. Therefore, generous laser indication is recommended if risk factors apply.

  1. Vitamin B supplementation for diabetic peripheral neuropathy.

    Science.gov (United States)

    Jayabalan, Bhavani; Low, Lian Leng

    2016-02-01

    Vitamin B12 deficiency has been associated with significant neurological pathology, especially peripheral neuropathy. This review aims to examine the existing evidence on the effectiveness of vitamin B12 supplementation for the treatment of diabetic peripheral neuropathy. A search of PubMed and the Cochrane Central Register of Controlled Trials for all relevant randomised controlled trials was conducted in December 2014. Any type of therapy using vitamin B12 or its coenzyme forms was assessed for efficacy and safety in diabetics with peripheral neuropathy. Changes in vibration perception thresholds, neuropathic symptoms and nerve conduction velocities, as well as the adverse effects of vitamin B12 therapy, were assessed. Four studies comprising 363 patients met the inclusion criteria. This review found no evidence that the use of oral vitamin B12 supplements is associated with improvement in the clinical symptoms of diabetic neuropathy. Furthermore, the majority of studies reported no improvement in the electrophysiological markers of nerve conduction. Copyright © Singapore Medical Association.

  2. Contrast media and pain during peripheral arteriography

    International Nuclear Information System (INIS)

    Hagen, B.; Clauss, W.

    1982-01-01

    Some contrast media (CM) were for inducing pain and heat by an intraindividual comparison in 60 patients with occlusive peripheral arterial disease. A dolorimeter and calorimeter (graduated scales) were employed to register and differentiate the subjective sensations experienced by the patient, while objective reactions (peripheral motoric reactions, circulatory parameters) were recorded by the trialist at the same time. Ioxaglate, an ionic dimer, was distinctly superior to Ioglicinate, an ionic CM. However, the differences were less marked in the comparison with a Ioglicinate-Lidocaine-mixture. Emphasis is given to the fact osmolality is the most important parameter in the development of pain. Potential points at which the intraarterially administered local anaesthetic could attack are discussed. The clinical conclusions include consideration of the cost-effectivity ratios of the tested CM's and a discussion of whether or not modern stanards still justify general anaesthesia for peripheral angiography. (orig.)

  3. Chronic obstructive pulmonary disease and peripheral neuropathy

    Directory of Open Access Journals (Sweden)

    Gupta Prem

    2006-01-01

    Full Text Available Chronic obstructive pulmonary disease (COPD is the fourth leading cause of death world-wide and a further increase in the prevalence as well as mortality of the disease is predicted for coming decades. There is now an increased appreciation for the need to build awareness regarding COPD and to help the thousands of people who suffer from this disease and die prematurely from COPD or its associated complication(s. Peripheral neuropathy in COPD has received scanty attention despite the fact that very often clinicians come across COPD patients having clinical features suggestive of peripheral neuropathy. Electrophysiological tests like nerve conduction studies are required to distinguish between axonal and demyelinating type of disorder that cannot be analyzed by clinical examination alone. However, various studies addressing peripheral neuropathy in COPD carried out so far have included patients with COPD having markedly varying baseline characteristics like severe hypoxemia, elderly patients, those with long duration of illness, etc. that are not uniform across the studies and make it difficult to interpret the results to a consistent conclusion. Almost one-third of COPD patients have clinical evidence of peripheral neuropathy and two-thirds have electrophysiological abnormalities. Some patients with no clinical indication of peripheral neuropathy do have electrophysiological deficit suggestive of peripheral neuropathy. The more frequent presentation consists of a polyneuropathy that is subclinical or with predominantly sensory signs, and the neurophysiological and pathological features of predominantly axonal neuropathy. The presumed etiopathogenic factors are multiple: chronic hypoxia, tobacco smoke, alcoholism, malnutrition and adverse effects of certain drugs.

  4. Separating volcanic deformation and atmospheric signals at Mount St. Helens using Persistent Scatterer InSAR

    Science.gov (United States)

    Welch, Mark D.; Schmidt, David A.

    2017-09-01

    Over the past two decades, GPS and leveling surveys have recorded cycles of inflation and deflation associated with dome building eruptions at Mount St. Helens. Due to spatial and temporal limitations of the data, it remains unknown whether any deformation occurred prior to the most recent eruption of 2004, information which could help anticipate future eruptions. Interferometric Synthetic Aperture Radar (InSAR), which boasts fine spatial resolution over large areas, has the potential to resolve pre-eruptive deformation that may have occurred, but eluded detection by campaign GPS surveys because it was localized to the edifice or crater. Traditional InSAR methods are challenging to apply in the Cascades volcanic arc because of a combination of environmental factors, and past attempts to observe deformation at Mount St. Helens were unable to make reliable observations in the crater or on much of the edifice. In this study, Persistent Scatterer InSAR, known to mitigate issues of decorrelation caused by environmental factors, is applied to four SAR data sets in an attempt to resolve localized sources of deformation on the volcano between 1995 and 2010. Many interferograms are strongly influenced by phase delay from atmospheric water vapor and require correction, evidenced by a correlation between phase and topography. To assess the bias imposed by the atmosphere, we perform sensitivity tests on a suite of atmospheric correction techniques, including several that rely on the correlation of phase delay to elevation, and explore approaches that directly estimate phase delay using the ERA-Interim and NARR climate reanalysis data sets. We find that different correction methods produce velocities on the edifice of Mount St. Helens that differ by up to 1 cm/yr due to variability in how atmospheric artifacts are treated in individual interferograms. Additionally, simple phase-based techniques run the risk of minimizing any surface deformation signals that may themselves be

  5. Photogrammetric Analysis of the Current Dome-Building Eruption of Mount St. Helens Volcano

    Science.gov (United States)

    Diefenbach, A. K.; Dzurisin, D.; Crider, J. G.; Schilling, S. P.

    2006-12-01

    Beginning in October 2004 and continuing to present day, the eruption of Mount St. Helens has provided a unique opportunity to experiment with new tools and techniques to study the dome-building eruption of a Cascade volcano. At the onset of eruption, a permanent camera station called Sugar Bowl was installed on the northeast rim of the crater about 2 km from the vent. Since that time, four additional cameras have been installed on the rim and crater floor to provide continuous visual observation of dome growth and crater conditions. We have analyzed images from four of the cameras to measure variations in three-dimensional lineal growth rates of lava spines extruding from the growing dome. Using photogrammetric techniques it is possible to obtain quantitative information on the geometry and displacement of a changing topographic model, in this case the evolving dome and glaciers in the crater of Mount St. Helens. The technique is an inexpensive, high-resolution, and efficient method that uses standard commercial software and an off-the-shelf digital camera to determine the x, y, z positions of selected points on the model surface. The model geometry at any given time is defined by the positions of all the points, and displacements are measured by tracking the changing positions of the points through time. Lineal extrusion rates during the first few months of the eruption ranged from 6-11 m/d, and subsequent estimates by other techniques were 4-5 m/d (Dzurisin et. al, 2005). For the past six months the extrusion rate has leveled off at 1 m/d, possibly indicative of steady-state extrusion or an approaching pause in the eruption. Another aspect of the project involves the use of overlapping oblique photos taken from a helicopter in 2004 and 2005 to produce fast and coarse digital elevation models (DEMs), which supplement high resolution DEMs produced by the USGS every 1 - 2 months. Comparing these results with seismicity and ground tilt measured by shallow borehole

  6. Classic Peripheral Signs of Subacute Bacterial Endocarditis

    Directory of Open Access Journals (Sweden)

    Yooyoung Chong

    2016-10-01

    Full Text Available A 50-year-old female patient with visual disturbances was referred for further evaluation of a heart murmur. Fundoscopy revealed a Roth spot in both eyes. A physical examination showed peripheral signs of infective endocarditis, including Osler nodes, Janeway lesions, and splinter hemorrhages. Our preoperative diagnosis was subacute bacterial endocarditis with severe aortic regurgitation. The patient underwent aortic valve replacement and was treated with intravenous antibiotics for 6 weeks postoperatively. The patient made a remarkable recovery and was discharged without complications. We report this case of subacute endocarditis with all 4 classic peripheral signs in a patient who presented with visual disturbance.

  7. Classic Peripheral Signs of Subacute Bacterial Endocarditis

    Science.gov (United States)

    Chong, Yooyoung; Han, Sung Joon; Rhee, Youn Ju; Kang, Shin Kwang; Yu, Jae Hyeon; Na, Myung Hoon

    2016-01-01

    A 50-year-old female patient with visual disturbances was referred for further evaluation of a heart murmur. Fundoscopy revealed a Roth spot in both eyes. A physical examination showed peripheral signs of infective endocarditis, including Osler nodes, Janeway lesions, and splinter hemorrhages. Our preoperative diagnosis was subacute bacterial endocarditis with severe aortic regurgitation. The patient underwent aortic valve replacement and was treated with intravenous antibiotics for 6 weeks postoperatively. The patient made a remarkable recovery and was discharged without complications. We report this case of subacute endocarditis with all 4 classic peripheral signs in a patient who presented with visual disturbance. PMID:27734006

  8. Peripheral phlebitis: a point-prevalence study.

    Science.gov (United States)

    Washington, Georgita T; Barrett, Robin

    2012-01-01

    The purpose of this research study was to determine the factors influencing peripheral phlebitis in the adult medical-surgical population. The authors would then be able to use those data to determine whether a change in practice was warranted. Data collection and analysis of 188 intravenous sites revealed that females with higher doses of medications in intravenous sites of longer dwell times and suboptimal nutrition were at greater risk of developing peripheral phlebitis. The point prevalence was greater than the recommended 5%, which led the authors to review their facility's patient care and documentation practices.

  9. Laser peripheral iridoplasty for angle-closure.

    Science.gov (United States)

    Ng, Wai Siene; Ang, Ghee Soon; Azuara-Blanco, Augusto

    2012-02-15

    Angle-closure glaucoma is a leading cause of irreversible blindness in the world. Treatment is aimed at opening the anterior chamber angle and lowering the IOP with medical and/or surgical treatment (e.g. trabeculectomy, lens extraction). Laser iridotomy works by eliminating pupillary block and widens the anterior chamber angle in the majority of patients. When laser iridotomy fails to open the anterior chamber angle, laser iridoplasty may be recommended as one of the options in current standard treatment for angle-closure. Laser peripheral iridoplasty works by shrinking and pulling the peripheral iris tissue away from the trabecular meshwork. Laser peripheral iridoplasty can be used for crisis of acute angle-closure and also in non-acute situations.   To assess the effectiveness of laser peripheral iridoplasty in the treatment of narrow angles (i.e. primary angle-closure suspect), primary angle-closure (PAC) or primary angle-closure glaucoma (PACG) in non-acute situations when compared with any other intervention. In this review, angle-closure will refer to patients with narrow angles (PACs), PAC and PACG. We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2011, Issue 12), MEDLINE (January 1950 to January 2012), EMBASE (January 1980 to January 2012), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to January 2012), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). There were no date or language restrictions in the electronic searches for trials. The electronic databases were last searched on 5 January 2012. We included only randomised controlled trials (RCTs) in this review. Patients with narrow angles, PAC or PACG were eligible. We excluded studies that included only patients with acute presentations

  10. [Degenerative lesions of the peripheral retina].

    Science.gov (United States)

    Conart, J-B; Baron, D; Berrod, J-P

    2014-01-01

    Degenerative lesions of the peripheral retina are present from teenage years onwards and increase with age. These abnormabilities are frequent, some of them being benign while others predispose to retinal tears and detachment. In the latter case, the lesions are rhegmatogenous and may justify prophylactic treatment by laser photocoagulation. We distinguish congenital lesions of the peripheral retina and intraretinal, chorioretinal and vitreoretinal degenerations. The holes and tears observed in 2% of the population consist of round atrophic holes, "horseshoe" tears, oral dialyses and giant tears. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  11. Radiation injury to peripheral and cranial nerves

    International Nuclear Information System (INIS)

    Giese, W.L.; Kinsella, T.J.

    1991-01-01

    In this paper, the results of laboratory and clinical investigations regarding the radiosensitivity of peripheral nerve are presented. Before outlining this research the authors briefly review peripheral neuroanatomy and physiology and then discuss variables associated with injury. It is important to remember that radiation injury is multifactorial in nature, and that the relative importance of individual factors is not well understood. Reports up through the middle of this century were fraught with rudimentary dosimetry, primitive investigative methods, and arbitrary endpoints that resulted in widely conflicting conclusions that continue to date

  12. A study of stress distribution in elbows mounted on stanchions

    International Nuclear Information System (INIS)

    Basavanhally, N.R.; Tonet, N.

    1983-01-01

    It is a common practice, both in the nuclear and power piping industry, to have integral attachments on piping to either form a restraint or an anchor. For small attachments, such as lugs, one can use the readily available methods (eg., ASME Code Case N-318) to evaluate the local stresses at these attachments. For elbows or curved pipes mounted on stanchions, the evaluation of local stresses is more complex. In the present analysis, a 3D finite element model was implemented to determine the stress intensification factor that can be applied to piping stress under internal pressure and in-plane bending type of loads. The analysis indicates that, for an internal pressure load, in-plane bending is generated. For such supports, a stress intensification factor should be used to account for the increased loads. The results also indicate that there is an optimum elbow to stanchion post radius ratio which should be used in designing such supports. (orig.)

  13. Pressure-Equalizing Cradle for Booster Rocket Mounting

    Science.gov (United States)

    Rutan, Elbert L. (Inventor)

    2015-01-01

    A launch system and method improve the launch efficiency of a booster rocket and payload. A launch aircraft atop which the booster rocket is mounted in a cradle, is flown or towed to an elevation at which the booster rocket is released. The cradle provides for reduced structural requirements for the booster rocket by including a compressible layer, that may be provided by a plurality of gas or liquid-filled flexible chambers. The compressible layer contacts the booster rocket along most of the length of the booster rocket to distribute applied pressure, nearly eliminating bending loads. Distributing the pressure eliminates point loading conditions and bending moments that would otherwise be generated in the booster rocket structure during carrying. The chambers may be balloons distributed in rows and columns within the cradle or cylindrical chambers extending along a length of the cradle. The cradle may include a manifold communicating gas between chambers.

  14. Solidly mounted resonators aging under harsh environmental conditions

    International Nuclear Information System (INIS)

    Ivira, B; Fillit, R Y; Ndagijimana, F; Benech, Ph; Boussey, J; Parat, G; Ancey, P

    2006-01-01

    A contribution to reliability studies of Solidly Mounted Resonators (SMR) submitted to harsh environments such as temperature and humidity is presented. Electrical, structural and chemical monitoring of representative parameters is performed by means of RF, DC characterizations and also X-ray diffraction coupled to X-fluorescence to assess aging in microstructures. Results indicate that humidity affects samples stronger than high temperature. From viewpoint of robustness, non-negligible effects of SiO 2 mass-loading on antiresonance and resonance frequencies are reported. Drifts of parameters for a lonely resonator and filter transmission are both in good accordance. Finally, the need of a full sheet passivation layer is demonstrated in order to protect metals and Aluminum Nitride (AlN) against oxidation and pollutant compounds respectively

  15. Plants Biodiversity of Jobolarangan Forest Mount Lawu: 2. Spermatophyta

    Directory of Open Access Journals (Sweden)

    SUHAR IRIANTO

    2001-07-01

    Full Text Available The objectives of the research were to make: (1 a list of Spermatophyte plants at Jobolarangan forest in mount Lawu, and (2 the ecological and the economical benefits of the plants. All Spermatophyte plants on the forest were studied. The research procedures were including species collection in the field, make up herbaria, morphological observations in the laboratory, and interview to residents and government administrations. The results showed that in the forest were found 142 species Spermatophyte plants, in which 126 species of 54 family were identified, consisting of 78 species of herbs, 26 species of bushes, and 21 species of trees. Ecological benefits of the plants were hydrological regulation, keep out landslide and erosions etc., however economical benefits of the plants were log, firewood, charcoal, honey bee, medicinal plants, etc.

  16. Electrical activity during the 2006 Mount St. Augustine volcanic eruptions

    Science.gov (United States)

    Thomas, Ronald J.; Krehbiel, Paul R.; Rison, William; Edens, H. E.; Aulich, G. D.; McNutt, S.R.; Tytgat, Guy; Clark, E.

    2007-01-01

    By using a combination of radio frequency time-of-arrival and interferometer measurements, we observed a sequence of lightning and electrical activity during one of Mount St. Augustine's eruptions. The observations indicate that the electrical activity had two modes or phases. First, there was an explosive phase in which the ejecta from the explosion appeared to be highly charged upon exiting the volcano, resulting in numerous apparently disorganized discharges and some simple lightning. The net charge exiting the volcano appears to have been positive. The second phase, which followed the most energetic explosion, produced conventional-type discharges that occurred within plume. Although the plume cloud was undoubtedly charged as a result of the explosion itself, the fact that the lightning onset was delayed and continued after and well downwind of the eruption indicates that in situ charging of some kind was occurring, presumably similar in some respects to that which occurs in normal thunderstorms.

  17. Advanced Helmet Mounted Display (AHMD) for simulator applications

    Science.gov (United States)

    Sisodia, Ashok; Riser, Andrew; Bayer, Michael; McGuire, James P.

    2006-05-01

    The Advanced Helmet Mounted Display (AHMD), augmented reality visual system first presented at last year's Cockpit and Future Displays for Defense and Security conference, has now been evaluated in a number of military simulator applications and by L-3 Link Simulation and Training. This paper presents the preliminary results of these evaluations and describes current and future simulator and training applications for HMD technology. The AHMD blends computer-generated data (symbology, synthetic imagery, enhanced imagery) with the actual and simulated visible environment. The AHMD is designed specifically for highly mobile deployable, minimum resource demanding reconfigurable virtual training systems to satisfy the military's in-theater warrior readiness objective. A description of the innovative AHMD system and future enhancements will be discussed.

  18. Air Distribution in a Room with Ceiling-Mounted Diffusers

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Heby, Thomas; Moeller-Jensen, Bertil

    2006-01-01

    . The characteristics of the air distribution systems are addressed by analysing the acceptable conditions for the supply flow rate and the temperature difference for the different systems. The paper shows that an air distribution system with ceiling-mounted air terminal units is able to generate comfortable velocity...... with swirling flow generates a flow pattern in the room which is rather uninfluenced by the thermal load. The flow is highly mixed above the occupied zone and the air movement penetrates the occupied zone close to the walls. All systems are tested in the same room with the same heat load consisting of two...... manikins, each sitting at a desk, two pc's and two desk lamps producing a total heat load of 480 W. The design of the air distribution system is in all five cases based on flow elements from the diffuser, a maximum velocity assumption and a critical vertical temperature gradient in the room...

  19. Optimization of Compressor Mounting Bracket of a Passenger Car

    Science.gov (United States)

    Kalsi, Sachin; Singh, Daljeet; Saini, J. S.

    2018-05-01

    In the present work, the CAE tools are used for the optimization of the compressor mounting bracket used in an automobile. Both static and dynamic analysis is done for the bracket. With the objective to minimize the mass and increase the stiffness of the bracket, the new design is optimized using shape and topology optimization techniques. The optimized design given by CAE tool is then validated experimentally. The new design results in lower level of vibrations, contribute to lower mass along with lesser cost which is effective in air conditioning system as well as the efficiency of a vehicle. The results given by CAE tool had a very good correlation with the experimental results.

  20. Post Traumatic Tension Pneumocephalus: The Mount Fuji Sign

    LENUS (Irish Health Repository)

    Ryan, J

    2017-04-01

    Pneumocephalus is defined as the presence of intracranial air. This is most commonly secondary to a traumatic head injury. Tension pneumocephalus presents radiologically with compression of the frontal lobes and widening of the interhemispheric space between the frontal lobes. It is often termed the Mount Fuji sign due to a perceived similarity with an iconic mountain peak in Japan. We present the case of a 52-year-old gentleman who presented to the emergency department shortly before 8am on a Saturday morning following an assault. He was alert and ambulatory with no clinical evidence of raised intracranial pressure. A plain radiograph of the facial bones showed significant pneumocephalus. A later CT was consistent with a tension pneumocephalus which usually necessitates urgent decompression.The patient showed no clinical signs or symptoms of raised intracranial pressure and was managed conservatively. He was discharged home 16 days later with no neurological deficit