WorldWideScience

Sample records for peripheral flat wedge

  1. Radial wedge flange clamp

    Science.gov (United States)

    Smith, Karl H.

    2002-01-01

    A radial wedge flange clamp comprising a pair of flanges each comprising a plurality of peripheral flat wedge facets having flat wedge surfaces and opposed and mating flat surfaces attached to or otherwise engaged with two elements to be joined and including a series of generally U-shaped wedge clamps each having flat wedge interior surfaces and engaging one pair of said peripheral flat wedge facets. Each of said generally U-shaped wedge clamps has in its opposing extremities apertures for the tangential insertion of bolts to apply uniform radial force to said wedge clamps when assembled about said wedge segments.

  2. Wakefield and the diffraction model due to a flat beam moving past a conducting wedge

    International Nuclear Information System (INIS)

    Chao, A.W.; Henke, H.

    1995-07-01

    A collimator is often used to clean a beam of its excessive tail particles. If the beam intensity is high enough or if the beam is brought too close to the collimator, however, the wakefields generated by the beam-collimator interaction can cause additional beam tails to grow, thus defeating, or even worsening, the beam-tail cleaning process. The wakefield generated by a sheet beam moving past a conducting wedge has been obtained in closed form by Henke using the method of conformal mapping. This result is applied in the present work to obtain the wake force and the transverse kick received by a test charge moving with the beam. For the beam to be approximated as sheet beams, it is assumed to be flat and the collimator is assumed to have an infinite extent in the flat dimention. We derive an exact expression for the transverse wake force delivered to particles in the beam bunch. Implication of emittance growth as a beam passes closely by a collimator is discussed. We consider two idealized wedge geometries: In Section 2, when the wedge has the geometry as a disrupted beam pipe, and in Section 3, when it is like a semi-infinite screen. Unfortunately, we do not have solutions for more realistic collimator geometries such as when it is tapered to minimize the wakefield effects. However, our results should still serve as pessimistic limiting cases. An interesting opportunity is offered by our exact calculation of the wakefields: it can be used to confront the diffraction model used to estimate the high-frequency impedance of a cavity structure. It is shown that the field pattern, as well as the impedance, agrees with those obtained by the diffraction model in appropriate limits

  3. Wedge-shaped parenchymal enhancement peripheral to the hepatic hemangioma : two-phase spiral CT findings

    International Nuclear Information System (INIS)

    Kim, Kyoung Won; Kim, Tae Kyoung; Han, Joon Koo; Kim, Ah Young; Lee, Hyun Ju; Song, Chi Sung; Choi, Byung Ihn

    2000-01-01

    To determine the incidence of hepatic hemangiomas associated with wedge-shaped parenchymal enhancements adjacent to the tumors as seen on two-phase spiral CT images obtained during the hepatic arterial phase and to characterize the two-phase spiral CT findings of those hemangiomas. One hundred and eight consecutive hepatic hemangiomas in 63 patients who underwent two-phase spiral CT scanning during an 11-month period were included in this study. Two-phase spiral CT scans were obtained during the hepatic arterial phase (30-second delay) and portal venous phase (65-second delay) after injection of 120 mL of contrast material at a rate of 3 mL/sec. We evaluated the frequency with which wedge-shaped parenchymal enhancement was adjacent to the hemangiomas during the hepatic arterial phase and divided hemangiomas into two groups according to whether or not wedge-shaped parenchymal enhancement was noted (Group A and Group B). The presence of such enhancement in hemangiomas was correlated with tumor size and the grade of intratumoral enhancement. In 24 of 108 hemangiomas, wedge-shaped parenchymal enhancement adjacent to hepatic tumors was seen on two-phase CT images obtained during the hepatic arterial phase. Mean hemangioma size was 22mm in group A and 24mm in group B. There was no statistically significant relationship between lesion size and the presence of wedge-shaped parenchymal enhancement adjacent to a hemangioma. In 91.7% and 100% of tumors in Group A, and in 9.6% and 17.8% in Group B, hemangiomas showed more than 50% intratumoral enhancement during the arterial and portal venous phase, respectively. Wedge-shaped parenchymal enhancements peripheral to hepatic hemangiomas was more frequently found in tumors showing more than 50% intratumoral enhancement during these two phases (p less than 0.01). Wedge-shaped parenchymal enhancements is not uncommonly seen adjacent to hepatic hemangiomas on two-phase spiral CT images obtained during the hepatic arterial phase. A

  4. Effects of Lateral Heel Wedges and Lateral Forefoot Wedge on the Knee Adduction Moment in Healthy Male Students

    Directory of Open Access Journals (Sweden)

    Fatemeh Shamsi

    2012-01-01

    Full Text Available Objective: Lateral wedged insoles have been designed to decrease the force applied on the medial knee compartment. The aim of this study was to assess the effects of laterally wedged insoles regarding to the placement of the wedge under the sole (under the heel or under the forefoot on the knee adduction moment and the ground reaction forces. Material & Methods: In this pretest-posttest study, three-dimensional gait analysis was performed on 20 healthy men between 18-30 years old. Knee adduction moment and ground reaction forces were compared among following three types of insoles: a flat insole, a 6˚ laterally inclined heel wedged insole and a 6˚ laterally- inclined forefoot wedged insole. Results: there was no difference between three conditions (flat insole (9.72±1.501, lateral heel wedge (9.866±2.141 and lateral forefoot wedge (9.952±1.986 in peak knee adduction moment (P>0.05. Ground reaction forces and spatiotemporal parameters of gait were not affected by any types of these insoles (P>0.05. Conclusion: Based on the current finding, placement of the lateral wedge under the sole, that is, under the heel or under the forefoot has no effect on the efficacy of these insoles on the adduction moment of the knee and ground reaction forces.

  5. Checking the virtual treatment modality Wedge from Siemens; Verificacion de la modalidad de tratamiento virtual WEDGE de SIEMENS

    Energy Technology Data Exchange (ETDEWEB)

    Suero Rodrigo, M. A.; Marques Fraguela, E.

    2011-07-01

    The treatment modality Virtual Wedge (VW) or implemented by Siemens virtual wedge in electron linear accelerators achieved dose distributions are similar but not identical, to those obtained with physical wedges. Among the advantages against the latter is the greater ease of use, wedge factor close to one, and lower peripheral dose. However, these benefits are to be effective requires a through quality control dependence because a larger number of parameters that control the generation of the beam, the dose monitor system and the movement of the jaws of the collimator. We performed a study of the wedge taking into account different configurations that can affect their behavior from the dosimetric point of view.

  6. Beam profiles in the nonwedged direction for dynamic wedges

    International Nuclear Information System (INIS)

    Lydon, J.M.; Rykers, K.L.

    1996-01-01

    One feature of the dynamic wedge is the improved flatness of the beam profile in the nonwedged direction when compared to fixed wedges. Profiles in the nonwedged direction for fixed wedges show a fall-off in dose away from the central axis when compared to the open field profile. This study will show that there is no significant difference between open field profiles and nonwedged direction profiles for dynamically wedged beams. The implications are that the dynamic wedge offers an improved dose distribution in the nonwedged direction that can be modelled by approximating the dynamically wedged field to an open field. This is possible as both the profiles and depth doses of the dynamically wedged fields match those of the open fields, if normalized to d max of the same field size. For treatment planning purposes the effective wedge factor (EWF) provides a normalization factor for the open field depth dose data set. Data will be presented to demonstrate that the EWF shows relatively little variation with depth and can be treated as being independent of field size in the nonwedged direction. (author)

  7. Graphene Plasmons in Triangular Wedges and Grooves

    DEFF Research Database (Denmark)

    Gonçalves, P. A. D.; Dias, E. J. C.; Xiao, Sanshui

    2016-01-01

    and tunability of graphene plasmons guided along the apex of a graphene-covered dielectric wedge or groove. In particular, we present a quasi-analytic model to describe the plasmonic eigenmodes in such a system, including the complete determination of their spectrum and corresponding induced potential...... and electric-field distributions. We have found that the dispersion of wedge/groove graphene plasmons follows the same functional dependence as their flat-graphene plasmon counterparts, but now scaled by a (purely) geometric factor in which all the information about the system’s geometry is contained. We...

  8. Comparison of dosimetric characteristics of Siemens virtual and physical wedges for ONCOR linear accelerator

    Directory of Open Access Journals (Sweden)

    Attalla Ehab

    2010-01-01

    Full Text Available Dosimetric properties of virtual wedge (VW and physical wedge (PW in 6- and 10-MV photon beams from a Siemens ONCOR linear accelerator, including wedge factors, depth doses, dose profiles, peripheral doses, are compared. While there is a great difference in absolute values of wedge factors, VW factors (VWFs and PW factors (PWFs have a similar trend as a function of field size. PWFs have stronger depth dependence than VWF due to beam hardening in PW fields. VW dose profiles in the wedge direction, in general, match very well with those of PW, except in the toe area of large wedge angles with large field sizes. Dose profiles in the nonwedge direction show a significant reduction in PW fields due to off-axis beam softening and oblique filtration. PW fields have significantly higher peripheral doses than open and VW fields. VW fields have similar surface doses as the open fields, while PW fields have lower surface doses. Surface doses for both VW and PW increase with field size and slightly with wedge angle. For VW fields with wedge angles 45° and less, the initial gap up to 3 cm is dosimetrically acceptable when compared to dose profiles of PW. VW fields in general use less monitor units than PW fields.

  9. Dosimetry and clinical implementation of dynamic wedge

    International Nuclear Information System (INIS)

    Klein, Eric E.; Low, Daniel A.; Meigooni, Ali S.; Purdy, James A.

    1995-01-01

    Purpose: Wedge-shaped isodoses are desired in a number of clinical situations. Physical wedge filters have provided nominal angled isodoses with dosimetric consequences of beam hardening, increased peripheral dosing, nonidealized gradients at deep depths, along with the practical consequences of filter handling and placement problems. Dynamic wedging uses a combination of a moving jaw and changing dose rate to achieve angled isodoses. The clinical implementation of dynamic wedge and an accompanying quality assurance program are discussed in detail. Methods and Materials: The accelerator at our facility has two photon energies (6 MV and 18 MV), currently with dynamic wedge angles of 15 deg. , 30 deg. , 45 deg. , and 60 deg. . The segmented treatment tables (STT) that drive the jaw in concert with a changing dose rate are unique for field sizes ranging from 4.0 cm to 20.0 cm in 05 cm steps, resulting in 256 STTs. Transmission wedge factors were measured for each STT with an ion chamber. Isodose profiles were accumulated with film after dose conversion. For treatment-planning purposes, d max orthogonal dose profiles were measured for open and dynamic fields. Physical filters were assigned empirically via the ratio of open and wedge profiles. Results: A nonlinear relationship with wedge factor and field size was found. The factors were found to be independent of the stationary field setting or second order blocking. Dynamic wedging provided more consistent gradients across the field compared with physical filters. Percent depth doses were found to be closer to open field. The created physical filters provided planned isodoses that closely resembled measured isodoses. Comparative isodose plans show improvement with dynamic wedging. Conclusions: Dynamic weding has practical and dosimetric advantages over physical filters. Table collisions with physical filters are alleviated. Treatment planning has been solved with an empirical solution. Dynamic wedge is a positive

  10. Workpiece Temperature Variations During Flat Peripheral Grinding

    Science.gov (United States)

    Smirnov, Vitalii A.; Repko, Aleksandr V.

    2018-06-01

    The paper presents the results of researches of temperature variations during flat peripheral grinding. It is shown that the temperature variations of the workpiece can reach 25...30% of the average values, which can lead to some thermal defects. A nonlinear two-dimensional thermophysical grinding model is suggested. It takes into account local changes in the cutting conditions: the fluctuation of the cut layer and the cutting force, the thermal impact of the cutting grains, and the presence of surface cavities in the intermittent wheel. For the numerical solution of the problem, the method of finite differences is adapted. Researches of the method stability and convergence are made, taking into account the specific nature of the problem. A high accuracy of the approximation of the boundary conditions and the nonlinear heat equation is provided. An experimental verification of the proposed thermophysical model was carried out with the use of installation for simultaneous measurement of the grinding force and temperature. It is shown that the discrepancy between the theoretical and experimental values of the grinding temperature does not exceed 5%. The proposed thermophysical model makes it possible to predict with high accuracy the temperature variations during grinding by the wheel periphery.

  11. Modelling the wedge shape for the virtual wedge

    International Nuclear Information System (INIS)

    Chang Liyun; Ho Shengyow; Chen, Helen H W

    2003-01-01

    We present a method to model the virtual wedge shape in a 3D treatment planning system as a physical wedge. The virtual wedge shape was determined using the measured dose profile of the virtual wedge at a chosen reference depth. The differences between the calculated and the measured dose profiles for the virtual wedge were within 0.5% at the reference depth, and within 2.5% at other depths. This method provides a fast and accurate way to implement the virtual wedge into our planning system for any wedge angles. This method is also applicable to model the physical wedge shapes with comparable good results

  12. A possible mechanism for earthquakes found in the mantle wedge of the Nazca subduction zone

    Science.gov (United States)

    Warren, L. M.; Chang, Y.; Prieto, G. A.

    2017-12-01

    Beneath Colombia, the Cauca cluster of intermediate-depth earthquakes extends for 200 km along the trench (3.5°N-5.5°N, 77.0°W-75.3°W) and, with 58 earthquakes per year with local magnitude ML >= 2.5, has a higher rate of seismicity than the subduction zone immediately to the north or south. By precisely locating 433 cluster earthquakes from 1/2010-3/2014 with data from the Colombian National Seismic Network, we found that the earthquakes are located both in a continuous Nazca plate subducting at an angle of 33°-43° and in the overlying mantle wedge. The mantle wedge earthquakes (12% of the earthquakes) form two isolated 40-km-tall columns extending perpendicular to the subducting slab. Using waveform inversion, we computed focal mechanisms for 69 of the larger earthquakes. The focal mechanisms are variable, but the intraslab earthquakes are generally consistent with an in-slab extensional stress axis oriented 25° counterclockwise from the down-dip direction. We suggest that the observed mantle wedge earthquakes are the result of hydrofracture in a relatively cool mantle wedge. This segment of the Nazca Plate is currently subducting at a normal angle, but Wagner et al. (2017) suggested that a flat slab slowly developed in the region between 9-5.9 Ma and persisted until 4 Ma. During flat slab subduction, the overlying mantle wedge typically cools because it is cut off from mantle corner flow. After hydrous minerals in the slab dehydrate, the dehydrated fluid is expelled from the slab and migrates through the mantle wedge. If a cool mantle wedge remains today, fluid dehydrated from the slab may generate earthquakes by hydrofracture, with the mantle wedge earthquakes representing fluid migration pathways. Dahm's (2000) model of water-filled fracture propagation in the mantle wedge shows hydrofractures propagating normal to the subducting slab and extending tens of km into the mantle wedge, as we observe.

  13. Physical characteristics comparison of virtual wedge device with physical wedge

    International Nuclear Information System (INIS)

    Cho, Jung Keun; Choi, Kye Sook; Lim, Cheong Hwan; Kim, Jeong Koo; Jung, Hong Ryang; Lee, Jung Ok; Lee, Man Goo

    2001-01-01

    We compared the characteristics of Siemens virtual wedge device with physical wedges for clinical application. We investigated the characteristics of virtual and physical wedges for various wedge angles (15, 30, 45, and 60) using 6- and 15- MV photon beams. Wedge factors were measured in water using an ion chamber for various field sizes and depths. In case of virtual wedge device, as upper jaw moves during irradiation, wedge angles were estimated by accumulated doses. These measurements were performed at off-axis points perpendicular to the beam central axis in water for a 15 cm x 20 cm radiation field size at the depth of 10 cm. Surface does without and with virtual or physical wedges were measured using a parallel plate ion chamber at surface. Field size was 15 cm * 20 cm and a polystyrene phantom was used. For various field sizes, virtual and physical wedge factors were changed by maximum 2.1% and 3.9%, respectively. For various depths, virtual and physical wedge factors were changed by maximum 1.9% and 2.9%, respectively. No major difference was found between the virtual and physical wedge angles and the difference was within 0.5. Surface dose with physical wedge was reduced by maximum 20% (x-ray beam : 6 MV, wedge angle : 45, SSD : 80 cm) relative to one with virtual wedge or without wedge. Comparison of the characteristics of Siemens virtual wedge device with physical wedges was performed. Depth dependence of virtual wedge factor was smaller than that of physical wedge factor. Virtual and physical wedge factors were nearly independent of field sizes. The accuracy of virtual and physical wedge angles was excellent. Surface dose was found to be reduced using a physical wedge

  14. Physical characteristics comparison of virtual wedge device with physical wedge

    International Nuclear Information System (INIS)

    Choi, Dong Rak; Shin, Kyung Hwan; Lee, Kyu Chan; Kim, Dae Yong; Ahn, Yong Chan; Lim, Do Hoon; Kim, Moon Kyung; Huh, Seung Jae

    1999-01-01

    We have compared the characteristics of Siemens virtual wedge device with physical wedges for clinical application. We investigated the characteristics of virtual and physical wedges for various wedge angles (15, 30, 45, and 60 ) using 6- and 15MV photon beams. Wedge factors were measured in water using an ion chamber for various field sizes and depths. In case of virtual wedge device, as upper jaw moves during irradiation, wedge angles were estimated by accumulated doses. These measurements were performed at off-axis points perpendicular to the beam central axis in water for a 15 cm x 20 cm radiation field size at the depth of 10 cm. Surface doses without and with virtual or physical wedges were measured using a parallel plate ion chamber at surface. Field size was 15 cm x 20 cm and a polystyrene phantom was used. For various field sizes, virtual and physical wedge factors were changed by maximum 2.1% and 3.9%, respectively. For various depths, virtual and physical wedge factors were changed by maximum 1.9% and 2.9%, respectively. No major difference was found between the virtual and physical wedge angles and the difference was within 0.5 .deg. . Surface dose with physical wedge was reduced by maximum 20% (x-ray beam: 6 MV, wedge angle: 45 .deg. , SSD: 80cm) relative to one with virtual wedge or without wedge. Comparison of the characteristics of Siemens virtual wedge device with physical wedges was performed. Depth dependence of virtual wedge factor was smaller than that of physical wedge factor. Virtual and physical wedge factors were nearly independent of field sizes. The accuracy of virtual and physical wedge angles was excellent. Surface dose was found to be reduced using physical wedge

  15. Investigation of turbulent wedges generated by different single surface roughness elements

    Science.gov (United States)

    Traphan, Dominik; Meinlschmidt, Peter; Lutz, Otto; Peinke, Joachim; Gülker, Gerd

    2013-11-01

    It is known that small faults on rotor blades of wind turbines can cause significant power loss. In order to better understand the governing physical effects, in this experimental study, the formation of a turbulent wedge over a flat plate induced by single surface roughness elements is under investigation. The experiments are performed at different ambient pressure gradients, thus allowing conclusions about the formation of a turbulent wedge over an airfoil. With respect to typical initial faults on operating airfoils, the roughness elements are modified in both size and shape (raised or recessed). None intrusive experimental methods, such as stereoscopic PIV and LDA, enable investigations based on temporally and spatially highly resolved velocity measurements. In this way, a spectral analysis of the turbulent boundary layer is performed and differences in coherent structures within the wedge are identified. These findings are correlated with global measurements of the wedge carried out by infrared thermography. This correlation aims to enable distinguishing the cause and main properties of a turbulent wedge by the easy applicable method of infrared thermography, which is of practical relevance in the field of condition monitoring of wind turbines.

  16. Reconstruction of Spectra Using X-ray Flat Panel Detector; Reconstruccion de Espectros de Rayos X Utilizando un Detector Flat Panel

    Energy Technology Data Exchange (ETDEWEB)

    Gallardo, S.; Querol, A.; Pozuelo, F.; Juste, B.; Rodenas, J.; Verdu, G.

    2013-07-01

    In this work, we used a flat panel detector with a wedge of PMMA for absorbed dose curve for given working conditions of X-ray tube The relationship between absorbed dose curve recorded by the flat panel and primary X-ray spectrum is defined by a response function that can be obtained using the Monte Carlo method, namely the MCNP5 code. However there are some problems that affect the applicability of this method such as: flat panel characteristics and the characteristics of the physical process (ill-conditioned problem). Both aspects are discussed in this paper.

  17. Wedge cutting of mild steel by CO 2 laser and cut-quality assessment in relation to normal cutting

    Science.gov (United States)

    Yilbas, B. S.; Karatas, C.; Uslan, I.; Keles, O.; Usta, Y.; Yilbas, Z.; Ahsan, M.

    2008-10-01

    In some applications, laser cutting of wedge surfaces cannot be avoided in sheet metal processing and the quality of the end product defines the applicability of the laser-cutting process in such situations. In the present study, CO 2 laser cutting of the wedge surfaces as well as normal surfaces (normal to laser beam axis) is considered and the end product quality is assessed using the international standards for thermal cutting. The cut surfaces are examined by the optical microscopy and geometric features of the cut edges such as out of flatness and dross height are measured from the micrographs. A neural network is introduced to classify the striation patterns of the cut surfaces. It is found that the dross height and out of flatness are influenced significantly by the laser output power, particularly for wedge-cutting situation. Moreover, the cut quality improves at certain value of the laser power intensity.

  18. Evaluation of the necessity for chest drain placement following thoracoscopic wedge resection.

    Science.gov (United States)

    Lu, Ting-Yu; Chen, Jian-Xun; Chen, Pin-Ru; Lin, Yu-Sen; Chen, Chien-Kuang; Kao, Pei-Yu; Huang, Tzu-Ming; Fang, Hsin-Yuan

    2017-05-01

    To evaluate the outcomes of patients who underwent thoracoscopic wedge resection without chest drain placement. The subjects of this retrospective study were 89 patients, who underwent thoracoscopic wedge resection at our hospital between January, 2013 and July, 2015. A total of 45 patients whose underlying condition did not meet the following criteria were assigned to the "chest drain placement group" (group A): peripheral lesions, healthy lung parenchyma, no intraoperative air leaks, hemorrhage or effusion accumulation, and no pleural adhesion. The other 44 patients whose underlying condition met the criteria were assigned to the "no chest drain placement group" (group B). Patient characteristics, specimen data, and postoperative conditions were analyzed and compared between the groups. Group A patients had poorer forced expiratory volume in one second (FEV1) values, less normal spirometric results, significantly higher resected lung volume, a greater maximum tumor-pleura distance, and a larger maximum tumor size. They also had a longer postoperative hospital stay. There was no difference between the two groups in postoperative complications. Avoiding chest drain placement after a thoracoscopic wedge resection appears to be safe and beneficial for patients who have small peripheral lesions and healthy lung parenchyma.

  19. Wedges I

    International Nuclear Information System (INIS)

    DeWitt-Morette, C.; Low, S.G.; Schulman, L.S.; Shiekh, A.Y.

    1986-01-01

    The wedge problem, that is, the propagation of radiation or particles in the presence of a wedge, is examined in different contexts. Generally, the paper follows the historical order from Sommerfeld's early work to recent stochastic results - hindsights and new results being woven in as appropriate. In each context, identifying the relevant mathematical problem has been the key to the solution. Thus each section can be given both a physics and a mathematics title: Section 2: diffraction by reflecting wedge; boundary value problem of differential equations; solutions defined on multiply connected spaces. Section 3: geometrical theory of diffraction; identification of function spaces. Section 4: path integral solutions; path integration on multiply connected spaces; asymptotics on the boundaries of function spaces. Section 5: probing the shape of the wedge and the roughness of its surface; stochastic calculus. Several propagators and Green functions are given explicitly, some old ones and some new ones. They include the knife-edge propagator for Dirichlet and Neumann boundary conditions, the absorbing knife edge propagator, the wedge propagators, the propagator for a free particle on a /sigma phi/-sheeted Riemann surface, the Dirichlet and the Neumann wedge Green function

  20. Dosimetric parameters of enhanced dynamic wedge for treatment planning and verification

    International Nuclear Information System (INIS)

    Leavitt, Dennis D.; Lee, Wing Lok; Gaffney, David K.

    1996-01-01

    of asymmetric fields having one continuous edge, with the dose delivered within each asymmetric field determined by the segmented treatment table provided by the vendor, and were directly compared with measured profiles. Two different calculation techniques were compared against measured data for symmetric and asymmetric wedge fields. Actual vs. desired wedge angle was determined for the full range of wedge angles and field sizes using the IEC definition for wedge angle. Results: EDW dose distributions for all wedge angles and field sizes are well represented as the sum of open-field and 60 degree dynamic wedge contributions weighted by the technique of ratio-of-tangents. This significantly minimizes the amount of measured or calculated data required within the treatment planning system. Wedge field central axis depth doses differ only marginally from open-field depth doses, with the maximum difference of less than 2% for the 20 cm wide 60 degree wedge field. These small differences are predicted based on dose to the central axis due to photon transmission through the collimating jaws and phantom scatter. The effective wedge factor decreases smoothly with field width and wedge angle up to 20 cm wide fields, then remains relatively 'flat' to the maximum field width. A simple extension of the ratio of tangents formula has been derived which predicts effective wedge factor for any field width and wedge angle and shows excellent agreement to both measured and explicitly calculated values. Two different calculation techniques show excellent agreement with measured EDW profiles for wedges centered on central axis; however, for asymmetric wedges only the explicit summation of segmented asymmetric fields is in good agreement with measured profiles. The idealized wedge angle is not maintained for all field widths and wedge angles; with greatest deviations noted for narrower fields. This is predicted, based on the mechanical technique used to generate the EDW tables

  1. Studying wedge factors and beam profiles for physical and enhanced dynamic wedges

    Directory of Open Access Journals (Sweden)

    Ahmad Misbah

    2010-01-01

    Full Text Available This study was designed to investigate variation in Varian′s Physical and Enhanced Dynamic Wedge Factors (WF as a function of depth and field size. The profiles for physical wedges (PWs and enhanced dynamic wedges (EDWs were also measured using LDA-99 array and compared for confirmation of EDW angles at different depths and field sizes. WF measurements were performed in water phantom using cylindrical 0.66 cc ionization chamber. WF was measured by taking the ratio of wedge and open field ionization data. A normalized wedge factor (NWF was introduced to circumvent large differences between wedge factors for different wedge angles. A strong linear dependence of PW Factor (PWF with depth was observed. Maximum variation of 8.9% and 4.1% was observed for 60° PW with depth at 6 and 15 MV beams respectively. The variation in EDW Factor (EDWF with depth was almost negligible and less than two per cent. The highest variation in PWF as a function of field size was 4.1% and 3.4% for thicker wedge (60° at 6 and 15 MV beams respectively and decreases with decreasing wedge angle. EDWF shows strong field size dependence and significant variation was observed for all wedges at both photon energies. Differences in profiles between PW and EDW were observed on toe and heel sides. These differences were dominant for larger fields, shallow depths, thicker wedges and low energy beam. The study indicated that ignoring depth and field size dependence of WF may result in under/over dose to the patient especially doing manual point dose calculation.

  2. Flat-port connectors

    KAUST Repository

    Alrashed, Mohammed

    2017-05-26

    Disclosed are various embodiments for connectors used with electronic devices, such as input and/or output ports to connect peripheral equipment or accessories. More specifically, various flat-port are provided that can be used in place of standard connectors including, but not limited to, audio jacks and Universal Serial Bus (USB) ports. The flat-port connectors are an alternate connection design to replace the traditional receptacle port (female-port), making the device more sealed creation more dust and water resistant. It is unique in the way of using the outer surfaces of the device for the electrical connection between the ports. Flat-port design can allow the manufacture of extremely thin devices by eliminating the side ports slots that take a lot of space and contribute to the increase thickness of the device. The flat-port receptacle improves the overall appearance of the device and makes it more resistant to dust and water.

  3. Clinical Application of Wedge Factor

    International Nuclear Information System (INIS)

    Choi, Dong Rak; Ahn, Yong Chan; Huh, Sueng Jae

    1995-01-01

    Purpose : In general. The wedge factors which are used clinical practices are ignored of dependency on field sizes and depths. In this present, we investigated systematically the depth and field size dependency to determine the absorbed dose more accurately. Methods : The wedge factors for each wedge filter were measured at various depth (depth of Dmax, 5cm, 10cm, and 15cm) and field sizes (5 X 5cm, 10 X 10cm, 15 X 15cm, 20 X 20 cm) by using 4-,6-, and 10-MV X rays. By convention, wedge factors are determined by taking the ratio of the central axis ionization readings when the wedge filter is in place to those of the open field in same field size and measurement depth. In this present work, we determined the wedge factors for 4-, 6-, and 10-MV X rays from Clinac 600C and 2100C linear accelerators (manufactured by Varian Associates, Inc., Palo Alto, CA). To confirm that the wedge was centered., measurements were done with the two possible wedge position and various collimator orientations. Results : The standard deviations of measured values are within 0.3% and the depth dependence of wedge factor is greater for the lower energies. Especially, the variation of wedge factor is no less than 5% for 4- and 6- MV X rays with more than 45 .deg. wedge filter. But there seems to be a small dependence on field size. Conclusion : The results of this study show a dependence on the point of measurement. There also seems to be a small dependence on field size. And so, we should consider the depth and field size dependence in determining the wedge factors. If one wedge factor were to be used for each wedge filter, it seems that the measurement for a 10cm X 10cm field size at a depth of 10cm would be a reasonable choice

  4. Measurement of hepatic venous pressure gradient revisited: Catheter wedge vs balloon wedge techniques

    Directory of Open Access Journals (Sweden)

    S Timothy Chelliah

    2011-01-01

    Full Text Available Aims: To evaluate the accuracy of measurement of hepatic venous pressure gradient by catheter wedge as compared to balloon wedge (the gold standard. Materials and Methods: Forty-five patients having a clinical diagnosis of intrahepatic portal hypertension were subjected to the two different types of pressure measurements (catheter wedge and balloon wedge during transjugular liver biopsy under fluoroscopic guidance. Statistical Analysis: Spearman′s rank correlation coefficient, Bland-Altman plot for agreement, and single measure intraclass correlation were used for analysis of data. Results: There was a close correlation between the results obtained by both the techniques, with highly significant concordance (P < 0.0001. Hepatic venous pressure gradients as measured by the catheter wedge technique were either equal to or less than those obtained by the balloon wedge technique. Conclusions: The difference in hepatic venous pressure gradients measured by the two techniques is insignificant.

  5. Clinical implementation of enhanced dynamic wedge

    International Nuclear Information System (INIS)

    Klein, Eric E.; Zhu Xiaorong; Low, Daniel A.; Drzymala, Robert E.; Harms, William B.; Purdy, James A.

    1996-01-01

    Purpose/Objective: Our clinic has been using dynamic wedge since 1993. We appreciate the customized wedge shaped distributions (independent of field size) and the positive aspects of replacing filters with dynamic jaw motion. Varian recently introduced enhanced dynamic wedge (EDW) software. The EDW can be delivered over; a 30 cm field, asymmetric fields (in both wedged and non-wedged directions), and additional wedge angles (10, 15, 20, 25, 30, 45, 60). The EDW software creates customized segmented treatment tables (STTs) for the desired wedge angle and field size. The STT is created from a 'golden' fluence profile of 60 deg. over 30 cm. The wedge STT is derived using ratio-of-tangents and the truncated field segment extracted from the 'golden' table. A review of our dosimetric studies will be presented as well as a discussion of clinical implementation issues including treatment planning and quality assurance. Methods and Materials: We tested a set of angle and field size combinations chosen to encompass clinical needs. The wedge factor (WF) was measured using an ionization chamber along central axis for symmetric fields ranging from 4 to 20 cm, and asymmetric fields to 30 cm. The non-wedged field dimension was found to be inconsequential. An algorithm was developed to predict the wedge factor for any angle and field dimension. Isodoses were measured with film and used for profile evaluation and treatment planning development. The 'golden' fluence table was used to create a universal 60 deg. 'physical' wedge for planning. The universal wedge is combined with an open field (to derive intermediate wedge angles) and blocked according to the treatment field segment. A quality assurance program was developed that relies on multi-point diode measurements. Results: We found the WF is a function of wedge angle and field settings of the final sweep position. There is a nearly linear dependence of WF vs. field size thus allowing a minimal WF table. This eliminates a

  6. Three-Dimensional Shear Wave Velocity Structure of the Peru Flat Slab Subduction Segment

    Science.gov (United States)

    Knezevic Antonijevic, S.; Wagner, L. S.; Beck, S. L.; Zandt, G.; Long, M. D.

    2012-12-01

    Recent studies focused on flat slab subduction segments in central Chile (L. S. Wagner, 2006) and Alaska (B. R. Hacker and G. A. Aber, 2012) suggest significant differences in seismic velocity structures, and hence, composition in the mantle wedge between flat and normal "steep" subducting slabs. Instead of finding the low velocities and high Vp/Vs ratios common in normal subduction zones, these studies find low Vp, high Vs, and very low Vp/Vs above flat slabs. This may indicate the presence of dry, cold material in the mantle wedge. In order to investigate the seismic velocities of the upper mantle above the Peruvian flat segment, we have inverted for 2D Rayleigh wave phase velocity maps using data from the currently deployed 40 station PULSE seismic network and some adjacent stations from the CAUGHT seismic network. We then used the sensitivity of surface waves to shear wave velocity structure with depth to develop a 3D shear wave velocity model. This model will allow us to determine the nature of the mantle lithosphere above the flat slab, and how this may have influenced the development of local topography. For example, dry conditions (high Vs velocities) above the flat slab would imply greater strength of this material, possibly making it capable of causing further inland overthrusting, while wet conditions (low Vs) would imply weaker material. This could provide some insight into the ongoing debate over whether the Fitzcarrald arch (along the northern most flank of the Altiplano) could be a topographical response to the subducted Nazca ridge hundred kilometers away from the trench (N. Espurt, 2012, P. Baby, 2005, V. A. Ramos, 2012) or not (J. Martinod, 2005, M. Wipf, 2008, T. Gerya, 2008).

  7. Temperature of Heating and Cooling of Massive, Thin, and Wedge-Shaped Plates from Hard-to-Machine Steels During Their Grinding

    Science.gov (United States)

    Dement‧ev, V. B.; Ivanova, T. N.; Dolginov, A. M.

    2017-01-01

    Grinding of flat parts occurs by solid abrasive particles due to the physicomechanical process of deformation and to the action of a process liquid at high temperatures in a zone small in volume and difficult for observation. The rate of heating and cooling depends on the change in the intensity of the heat flux and in the velocity and time of action of the heat source. A study has been made of the regularities of the influence of each of these parameters on the depth and character of structural transformations during the grinding of flat parts from hard-to-machine steels. A procedure to calculate temperature in grinding massive, thin, and wedge-shaped parts has been developed with account taken of the geometric and thermophysical parameters of the tool and the treated part, and also of cutting regimes. The procedure can be used as a constituent part in developing a system for automatic design of the technological process of grinding of flat surfaces. A relationship between the temperature in the grinding zone and the regimes of treatment has been established which makes it possible to control the quality of the surface layer of massive, thin, and wedge-shaped plates from hard-to-machine steels. The rational boundaries of shift of cutting regimes have been determined.

  8. Observation of the dispersion of wedge waves propagating along cylinder wedge with different truncations by laser ultrasound technique

    Science.gov (United States)

    Jia, Jing; Zhang, Yu; Han, Qingbang; Jing, Xueping

    2017-10-01

    The research focuses on study the influence of truncations on the dispersion of wedge waves propagating along cylinder wedge with different truncations by using the laser ultrasound technique. The wedge waveguide models with different truncations were built by using finite element method (FEM). The dispersion curves were obtained by using 2D Fourier transformation method. Multiple mode wedge waves were observed, which was well agreed with the results estimated from Lagasse's empirical formula. We established cylinder wedge with radius of 3mm, 20° and 60°angle, with 0μm, 5μm, 10μm, 20μm, 30μm, 40μm, and 50μm truncations, respectively. It was found that non-ideal wedge tip caused abnormal dispersion of the mode of cylinder wedge, the modes of 20° cylinder wedge presents the characteristics of guide waves which propagating along hollow cylinder as the truncation increasing. Meanwhile, the modes of 60° cylinder wedge with truncations appears the characteristics of guide waves propagating along hollow cylinder, and its mode are observed clearly. The study can be used to evaluate and detect wedge structure.

  9. Rethinking wedges

    Science.gov (United States)

    Davis, Steven J.; Cao, Long; Caldeira, Ken; Hoffert, Martin I.

    2013-03-01

    Abstract Stabilizing CO2 emissions at current levels for fifty years is not consistent with either an atmospheric CO2 concentration below 500 ppm or global temperature increases below 2 °C. Accepting these targets, solving the climate problem requires that emissions peak and decline in the next few decades, and ultimately fall to near zero. Phasing out emissions over 50 years could be achieved by deploying on the order of 19 'wedges', each of which ramps up linearly over a period of 50 years to ultimately avoid 1 GtC y-1 of CO2 emissions. But this level of mitigation will require affordable carbon-free energy systems to be deployed at the scale of tens of terawatts. Any hope for such fundamental and disruptive transformation of the global energy system depends upon coordinated efforts to innovate, plan, and deploy new transportation and energy systems that can provide affordable energy at this scale without emitting CO2 to the atmosphere. 1. Introduction In 2004, Pacala and Socolow published a study in Science arguing that '[h]umanity can solve the carbon and climate problem in the first half of this century simply by scaling up what we already know how to do' [1]. Specifically, they presented 15 options for 'stabilization wedges' that would grow linearly from zero to 1 Gt of carbon emissions avoided per year (GtC y-1 1 Gt = 1012 kg) over 50 years. The solution to the carbon and climate problem, they asserted, was 'to deploy the technologies and/or lifestyle changes necessary to fill all seven wedges of the stabilization triangle'. They claimed this would offset the growth of emissions and put us on a trajectory to stabilize atmospheric CO2 concentration at 500 ppm if emissions decreased sharply in the second half of the 21st century. The wedge concept has proven popular as an analytical tool for considering the potential of different technologies to reduce CO2 emissions. In the years since the paper was published, it has been cited more than 400 times, and

  10. Comparing virtual with physical wedge for the transmission factors

    International Nuclear Information System (INIS)

    Lin Kuei-Hua; Lin Jao-Perng; Chu Tieh-Chi; Liu Mu-Tai

    2000-01-01

    This paper investigates the discrepancies between virtual wedge and physical wedge at the standard wedge angles of 15, 30, 45, and 60 degrees. The dose distributions for virtual wedge and physics wedge were measured by using a commercial multichamber detector array. The transmission factors of each virtual wedge and physical wedge were measured for Siemens PRIMUS 3008 linear accelerator by single ion chamber. These factors were used to set-up the clinical treatment data tables for clinical dosimetry for virtual wedge utilization. The Wellhoefer IC15, 0.13cc chamber was installed on the chamber frame of Wellhoefer water phantom (48x48x40 cm 3 ). The surface of water was at 100 cm SSD. The output factor in water were measured on the central axis of each field at 5 cm depth for 6MV or 10 cm depth for 15MV X-ray on virtual wedge and physical wedge. Comparing virtual wedge with physical wedge for transmission factor as field size range from 4x4 to 25x25 cm 2 . We have measured the dose distributions using the chamber array for 25x25 cm 2 virtual wedge fields and physical wedge fields at wedge angles of 15deg to 60deg. The dose profiles at various depths were also measured using the chamber array. The transmission factors of each physical wedge were slowly increased as field sizes increase, and had different value for each wedge angle. The transmission factors of each virtual wedge were almost constant value as 1.0 for each wedge angle. The results show that the dose profiles including the penumbra dose measured by the chamber array for virtual wedge agree with those measured for the physical wedge. For transmission factors of virtual wedge were constant value as 1.0 for each angles, namely output without wedge is almost equal to output with wedge on the central axis. Virtual wedge has practical and dosimetric advantages over physical wedge. (author)

  11. Contralateral breast dose reduction using a virtual wedge

    International Nuclear Information System (INIS)

    Yeo, In Hwan; Kim, Dae Yong; Kim, Tae Hyun; Shin, Kyung Hwan; Chie, Eui Kyu; Park, Won; Lim, Do Hoon; Huh, Seung Jae; Ahn, Yong Chan

    2005-01-01

    To evaluate the contralateral breast dose using a virtual wedge compared with that using a physical wedge and an open beam in a Siemens linear accelerator. The contralateral breast dose was measured using diodes placed on a humanoid phantom. Diodes were placed at 5.5 cm (position 1), 9.5 cm (position 2), and 14 cm (position 3) along the medial-lateral line from the medial edge of the treatment field. A 6-MV photon beam was used with tangential irradiation technique at 50 and 230 degrees of gantry angle. Asymmetrically collimated 17 x 10 cm field was used. For the first set of experiment, four treatment set-ups were used, which were an open medial beam with a 30-degree wedged lateral beam (physical and virtual wedges, respectively) and a 15-degree wedge medial beam with a 15-degree wedged lateral beam (physical and virtual wedges, respectively). The second set of experiment consists of setting with medial beam without wedge, a 15-degree wedge, and a 60-degree wedge (physical and virtual wedges, respectively). Identical monitor units were delivered. Each set of experiment was repeated for three times. In the first set of experiment, the contralateral breast dose was the highest at the position 1 and decreased in order of the position 2 and 3. The contralateral breast dose was reduced with open beam on the medial side (2.70± 1.46%) compared to medial beam with a wedge (both physical and virtual) (3.25 ± 1.59%). The differences were larger with a physical wedge (0.99 ± 0.18%) than a virtual wedge (0.10 ± 0.01%) at all positions. The use of a virtual wedge reduced the contralateral breast dose by 0.12% to 1.20% of the prescribed dose compared to a physical wedge with same technique. In the second experiment, the contralateral breast dose decreased in order of the open beam, the virtual wedge, and the physical wedge at the position 1, and it decreased in order of a physical wedge, an open beam, and a virtual wedge at the position 2 and 3. The virtual wedge equipped

  12. Phase Space Exchange in Thick Wedge Absorbers

    Energy Technology Data Exchange (ETDEWEB)

    Neuffer, David [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2017-01-01

    The problem of phase space exchange in wedge absorbers with ionization cooling is discussed. The wedge absorber exchanges transverse and longitudinal phase space by introducing a position-dependent energy loss. In this paper we note that the wedges used with ionization cooling are relatively thick, so that single wedges cause relatively large changes in beam phase space. Calculation methods adapted to such “thick wedge” cases are presented, and beam phase-space transformations through such wedges are discussed.

  13. Optical dating of relict sand wedges and composite-wedge pseudomorphs in Flanders, Belgium

    DEFF Research Database (Denmark)

    Buylaert, Jan-Pieter; Ghysels, Günther; Murray, Andrew S.

    2009-01-01

    We report on quartz Optically Stimulated Luminescence (OSL) dating of the infill of 14 relict sand wedges and composite-wedge pseudomorphs at 5 different sites in Flanders, Belgium. A laboratory dose recovery test indicates that the single-aliquot regenerative-dose (SAR) procedure is suitable for...

  14. A practical method to calculate head scatter factors in wedged rectangular and irregular MLC shaped beams for external and internal wedges

    International Nuclear Information System (INIS)

    Georg, Dietmar; Olofsson, Joergen; Kuenzler, Thomas; Aiginger, Hannes; Karlsson, Mikael

    2004-01-01

    Factor based methods for absorbed dose or monitor unit calculations are often based on separate data sets for open and wedged beams. The determination of basic beam parameters can be rather time consuming, unless equivalent square methods are applied. When considering irregular wedged beams shaped with a multileaf collimator, parametrization methods for dosimetric quantities, e.g. output ratios or wedge factors as a function of field size and shape, become even more important. A practical method is presented to derive wedged output ratios in air (S c,w ) for any rectangular field and for any irregular MLC shaped beam. This method was based on open field output ratios in air (S c ) for a field with the same collimator setting, and a relation f w between S c,w and S c . The relation f w can be determined from measured output ratios in air for a few open and wedged fields including the maximum wedged field size. The function f w and its parametrization were dependent on wedge angle and treatment head design, i.e. they were different for internal and external wedges. The proposed method was tested for rectangular wedged fields on three accelerators with internal wedges (GE, Elekta, BBC) and two accelerators with external wedges (Varian). For symmetric regular beams the average deviation between calculated and measured S c,w /S c ratios was 0.3% for external wedges and about 0.6% for internal wedges. Maximum deviations of 1.8% were obtained for elongated rectangular fields on the GE and ELEKTA linacs with an internal wedge. The same accuracy was achieved for irregular MLC shaped wedged beams on the accelerators with MLC and internal wedges (GE and Elekta), with an average deviation <1% for the fields tested. The proposed method to determine output ratios in air for wedged beams from output ratios of open beams, combined with equivalent square approaches, can be easily integrated in empirical or semi-empirical methods for monitor unit calculations

  15. Inclined indentation of smooth wedge in rock mass

    Science.gov (United States)

    Chanyshev, AI; Podyminogin, GM; Lukyashko, OA

    2018-03-01

    The article focuses on the inclined rigid wedge indentation into a rigid-plastic half-plane of rocks with the Mohr–Coulomb-Mohr plasticity. The limiting loads on different sides of the wedge are determined versus the internal friction angle, cohesion and wedge angle. It is shown that when the force is applied along the symmetry axis of the wedge, the zone of plasticity is formed only on one wedge side. In order to form the plasticity zone on both sides of the wedge, it is necessary to apply the force asymmetrically relative to the wedge symmetry axis. An engineering solution for the asymmetrical case implementation is suggested.

  16. Nature of the Coastal Range Wedge Along the Rupture Area of the 2015, Illapel Chile Earthquake Mw 8.4

    Science.gov (United States)

    Farías, M.; Comte, D.; Roecker, S. W.; Brandon, M. T.

    2017-12-01

    Wedge theory is usually applied to the pro-side of active subduction margins, where fold-and-thrust belts related to frontal accretion develop, but rarely to the entire wedge, where the retro-side is also relevant. We present a new 3D body wave tomographic image that combines data from the Chile-Illapel Aftershock Experiment (CHILLAX) with previous temporary seismic networks, with the aim of illuminating the nature of the wedge of the continental margin above the seismogenic part of the subducting slab. The downdip extent of the coupled part, called the S-point in the wedge theory, corresponds to the place where upper plate completely decouples from the subducting slab. This point is characterized by a Vp/Vs contrast at about 60 km depth that extends upward-and-eastward in a west-dipping ramp-like geometry. This ramp emerges about 180 km from the trench, near the topographic break related to the front of the Andean retro-side. The Coastal wedge domain is characterized by a monotonous east-dipping homocline with the older rocks of this region along the coast. The offshore region, corresponding to the pro-side, exhibits normal faulting and a very small frontal accretionary complex. Normal faulting in this region is related to rapid uplift of marine terraces since ca. 2 Ma, suggesting strong basal accretion and thus high friction on the thrust. In fact, the epicentral region of the 2015 Illapel Earthquake coincides with the highest elevations along the coast, i.e., the region with the highest slope of the margin. In this region, the lack of a continental forearc basin suggests an overlapping between the Andean and Coastal wedges. The western edge of the Andean wedge is also part of the homocline about 10 km east of the topographic boundary between both wedges, suggesting that the Coastal wedge has been deforming a part of the retro-side of the Andean wedge during the Miocene. The east-ward tilting of the retro-side was acquired mainly before the late Miocene, since at

  17. Three-beam interferogram analysis method for surface flatness testing of glass plates and wedges

    Science.gov (United States)

    Sunderland, Zofia; Patorski, Krzysztof

    2015-09-01

    When testing transparent plates with high quality flat surfaces and a small angle between them the three-beam interference phenomenon is observed. Since the reference beam and the object beams reflected from both the front and back surface of a sample are detected, the recorded intensity distribution may be regarded as a sum of three fringe patterns. Images of that type cannot be succesfully analyzed with standard interferogram analysis methods. They contain, however, useful information on the tested plate surface flatness and its optical thickness variations. Several methods were elaborated to decode the plate parameters. Our technique represents a competitive solution which allows for retrieval of phase components of the three-beam interferogram. It requires recording two images: a three-beam interferogram and the two-beam one with the reference beam blocked. Mutually subtracting these images leads to the intensity distribution which, under some assumptions, provides access to the two component fringe sets which encode surfaces flatness. At various stages of processing we take advantage of nonlinear operations as well as single-frame interferogram analysis methods. Two-dimensional continuous wavelet transform (2D CWT) is used to separate a particular fringe family from the overall interferogram intensity distribution as well as to estimate the phase distribution from a pattern. We distinguish two processing paths depending on the relative density of fringe sets which is connected with geometry of a sample and optical setup. The proposed method is tested on simulated data.

  18. Sandbox Simulations of the Evolution of a Subduction Wedge following Subduction Initiation

    Science.gov (United States)

    Brandon, M. T.; Ma, K. F.; DeWolf, W.

    2012-12-01

    Subduction wedges at accreting subduction zones are bounded by a landward dipping pro-shear zone (= subduction thrust) and a seaward-dipping retro-shear zone in the overriding plate. For the Cascadia subduction zone, the surface trace of the retro-shear zone corresponds to the east side of the Coast Ranges of Oregon and Washington and the Insular Mountains of Vancouver Island. This coastal high or forearc high shows clear evidence of long-term uplift and erosion along its entire length, indicating that it is an active part of the Cascadia subduction wedge. The question addressed here is what controls the location of the retro-shear zone? In the popular double-sided wedge model of Willet et al (Geology 1993), the retro-shear zone remains pinned to the S point, which is interpreted to represent where the upper-plate Moho intersects the subduction zone. For this interpretation, the relatively strong mantle is considered to operate as a flat backstop. That model, however. is somewhat artificial in that the two plates collide in a symmetric fashion with equal crustal thicknesses on both sides. Using sandbox experiments, we explore a more realistic configuration where the upper and lower plate are separated by a gentle dipping (10 degree) pro-shear zone, to simulate the initial asymmetric geometry of the subduction thrust immediately after initiation of subduction. The entire lithosphere must fail along some plane for subduction to begin and this failure plane must dip in the direction of subduction. Thus, the initial geometry of the overriding plate is better approximated as a tapered wedge than as a layer of uniform thickness, as represented in the Willett et al models. We demonstrate this model using time-lapse movies of a sand wedge above a mylar subducting plate. We use particle image velocimetry (PIV) to show the evolution of strain and structure within the overriding plate. Material accreted to the tapered end of the overriding plate drives deformation and causes

  19. Use of Wedge Absorbers in MICE

    Energy Technology Data Exchange (ETDEWEB)

    Neuffer, D. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Summers, D. [Univ. of Mississippi, Oxford, MS (United States); Mohayai, T. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); IIT, Chicago, IL (United States); Snopok, P. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); IIT, Chicago, IL (United States); Rogers, C. [Science and Technology Facilities Council (STFC), Oxford (United Kingdom). Rutherford Appleton Lab. (RAL)

    2017-03-01

    Wedge absorbers are needed to obtain longitudinal cooling in ionization cooling. They also can be used to obtain emittance exchanges between longitudinal and transverse phase space. There can be large exchanges in emittance, even with single wedges. In the present note we explore the use of wedge absorbers in the MICE experiment to obtain transverse–longitudinal emittance exchanges within present and future operational conditions. The same wedge can be used to explore “direct” and “reverse” emittance exchange dynamics, where direct indicates a configuration that reduces momentum spread and reverse is a configuration that increases momentum spread. Analytical estimated and ICOOL and G4BeamLine simulations of the exchanges at MICE parameters are presented. Large exchanges can be obtained in both reverse and direct configurations.

  20. Wedged multilayer Laue lens

    International Nuclear Information System (INIS)

    Conley, Ray; Liu Chian; Qian Jun; Kewish, Cameron M.; Macrander, Albert T.; Yan Hanfei; Maser, Joerg; Kang, Hyon Chol; Stephenson, G. Brian

    2008-01-01

    A multilayer Laue lens (MLL) is an x-ray focusing optic fabricated from a multilayer structure consisting of thousands of layers of two different materials produced by thin-film deposition. The sequence of layer thicknesses is controlled to satisfy the Fresnel zone plate law and the multilayer is sectioned to form the optic. An improved MLL geometry can be created by growing each layer with an in-plane thickness gradient to form a wedge, so that every interface makes the correct angle with the incident beam for symmetric Bragg diffraction. The ultimate hard x-ray focusing performance of a wedged MLL has been predicted to be significantly better than that of a nonwedged MLL, giving subnanometer resolution with high efficiency. Here, we describe a method to deposit the multilayer structure needed for an ideal wedged MLL and report our initial deposition results to produce these structures

  1. Manual cross check of computed dose times for motorised wedged fields

    International Nuclear Information System (INIS)

    Porte, J.

    2001-01-01

    If a mass of tissue equivalent material is exposed in turn to wedged and open radiation fields of the same size, for equal times, it is incorrect to assume that the resultant isodose pattern will be effectively that of a wedge having half the angle of the wedged field. Computer programs have been written to address the problem of creating an intermediate wedge field, commonly known as a motorized wedge. The total exposure time is apportioned between the open and wedged fields, to produce a beam modification equivalent to that of a wedged field of a given wedge angle. (author)

  2. Mantle wedge serpentinization effects on slab dips

    Directory of Open Access Journals (Sweden)

    Eh Tan

    2017-01-01

    Full Text Available The mechanical coupling between a subducting slab and the overlying mantle wedge is an important factor in controlling the subduction dip angle and the flow in mantel wedge. This paper investigates the role of the amount of mantle serpentinization on the subduction zone evolution. With numerical thermos-mechanical models with elasto-visco-plastic rheology, we vary the thickness and depth extent of mantle serpentinization in the mantle wedge to control the degree of coupling between the slab and mantle wedge. A thin serpentinized mantle layer is required for stable subduction. For models with stable subduction, we find that the slab dip is affected by the down-dip extent and the mantle serpentinization thickness. A critical down-dip extent exists in mantle serpentinization, determined by the thickness of the overriding lithosphere. If the down-dip extent does not exceed the critical depth, the slab is partially coupled to the overriding lithosphere and has a constant dip angle regardless of the mantle serpentinization thickness. However, if the down-dip extent exceeds the critical depth, the slab and the base of the overriding lithosphere would be separated and decoupled by a thick layer of serpentinized peridotite. This allows further slab bending and results in steeper slab dip. Increasing mantle serpentinization thickness will also result in larger slab dip. We also find that with weak mantle wedge, there is no material flowing from the asthenosphere into the serpentinized mantle wedge. All of these results indicate that serpentinization is an important ingredient when studying the subduction dynamics in the mantle wedge.

  3. 49 CFR 215.113 - Defective plain bearing wedge.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Defective plain bearing wedge. 215.113 Section 215... Suspension System § 215.113 Defective plain bearing wedge. A railroad may not place or continue in service a car, if a plain bearing wedge on that car is— (a) Missing; (b) Cracked; (c) Broken; or (d) Not located...

  4. Chevron closing base wedge bunionectomy.

    Science.gov (United States)

    Bruyn, J M

    1993-01-01

    The Chevron-base wedge Association for Osteosynthesis fixated bunionectomy provides a stable, aggressive correction of the severe hallux abducto valgus deformity. It is intended for the bunion requiring a double osteotomy in order to adequately reduce both intermetatarsal and proximal articular facet angle with minimal shortening and elevation. This article presents the rationale for the procedure, technique, and a 4-year follow-up of six patients with eight Chevron-base wedge bunionectomies.

  5. Dosimetry verifications of the physical parameters of virtual wedge on a Siemens accelerator

    International Nuclear Information System (INIS)

    Zhong Heli; Li Xiaodong; Li Longxing

    2002-01-01

    Objective: To verify the wedge angle of virtual wedge and the relation between wedge factor and beam energy, field size, wedge angle and to study the difference in percent depth dose (PDD) of virtual wedge field, hard wedge field and open field. Methods: Using wedge angle and wedge factor of 15 degree, 30 degree, 45 degree and 60 degree virtual wedge of Siemens Mevatron 6 MV and Primus 8 MV, 18 MV X rays were measured by RFA-plus 3D water phantom and RK finger chamber the PDD of the virtual wedge field, hard wedge field and open field were measured by Kodak XV-2 verifying film and FDM-300 film dosimeter. These PDDs were normalized to Dmax then compared. Results: There was good conformation between virtual wedge measured by four point method and set value. The virtual wedge was almost equal to 1, with a maximal variation of 0.031 no matter what the value of beam energy, field size or wedge angle was. Generally, for certain energy and field size, the wedge factor of larger wedge angle was slightly larger than smaller wedge angle. For certain energy and wedge angle, the wedge factor of larger field was also a little larger than smaller field. The PDD of virtual wedge field was similar to that of open field. Conclusions: The four point method measurement for virtual wedge angle is good for daily QA. Radiotherapy of virtual wedge field is not only simpler than hard wedge field, but also spares the beam output. The PDD conferment between virtual field and open field simplifies radiation treatment planning and increases the accuracy of wedge field therapy

  6. Peripheral Avascular Retina in a Term Male Neonate With Microvillus Inclusion Disease and Pancreatic Insufficiency.

    Science.gov (United States)

    Paulus, Yannis M; Alcorn, Deborah M; Gaynon, Michael; Moshfeghi, Darius M

    2015-05-01

    The authors present the first case of peripheral avascular retina in a term male neonate with pancreatic exocrine insufficiency, atypical microvillus inclusion disease, flat tympanograms, and recurrent urinary tract infections. Clinical examination showed avascular peripheral retina to posterior zone II temporally, with a flat stage 1-like demarcation line, and no plus disease. Genetic testing results were normal. The patient developed peripheral neovascularization and underwent panretinal photocoagulation. This case likely represents mild Norrie disease, familial exudative vitreoretinopathy, or incontinentia pigmenti due to a Wnt signaling abnormality. While these conditions are usually more severe, a variable spectrum of Wnt abnormalities exists throughout the body. Copyright 2015, SLACK Incorporated.

  7. Diffraction by an immersed elastic wedge

    CERN Document Server

    Croisille, Jean-Pierre

    1999-01-01

    This monograph presents the mathematical description and numerical computation of the high-frequency diffracted wave by an immersed elastic wave with normal incidence. The mathematical analysis is based on the explicit description of the principal symbol of the pseudo-differential operator connected with the coupled linear problem elasticity/fluid by the wedge interface. This description is subsequently used to derive an accurate numerical computation of diffraction diagrams for different incoming waves in the fluid, and for different wedge angles. The method can be applied to any problem of coupled waves by a wedge interface. This work is of interest for any researcher concerned with high frequency wave scattering, especially mathematicians, acousticians, engineers.

  8. Convolution-wedge product of fields

    International Nuclear Information System (INIS)

    Diep, D.N.; Duc, D.V.; Tan, H.V.; Viet, N.A.

    2007-07-01

    In this paper we use the pair of electric-magnetic (or GNO, or Langlands) duality groups G = Sp(1) and L G = SO(3) and the T-transformation in mirror symmetry (or the S-duality, or the Fourier-Mukai transformation) to define the wedge product of fields: first by using gauge transformation, we reduce the fields with values in LieG = sp(1) to the fields with values in the Lie algebra of the maximal torus t subset of LieG = sp(1). Next we use the Fourier-Mukai transformation of fields to have the images as fields with values in the Lie algebra of the Langlands dual torus L t in Lie L G = so(3). The desired wedge product of two fields is defined as the pre-image of the ordinary wedge product of images with values in L t subset of so(3). (author)

  9. Field size dependence of wedge factor: miniphantom vs full phantom measurements

    International Nuclear Information System (INIS)

    Allen Li, X.; Szanto, J.; Soubra, M.; Gerig, L. H.

    1995-01-01

    It is empirically known that the transmission factor for wedge in a high-energy photon beam is dependent upon field size and depth of measurement. The field-size dependence of wedge factors may be attributed to changes in (i) head scatter, (ii) phantom scatter, and (iii) backscatter from the wedge into the linac monitor chamber. In this work we present the results of studies designed to examine each of these factors in isolation. The wedge factors for wedges with nominal wedge angles of 15 deg. , 30 deg. , 45 deg. and 60 deg. were measured with a 3-g/cm 2 -diameter narrow cylindrical phantom (miniphantom), a brass cap with 1.5-g/cm 2 side-wall thickness and a full water phantom for 6-, 10- and 18-MV photon beams. The measurements were performed with and without flattening filter in place. The wedge factors measured with the miniphantom and the brass cap exclude the phantom scatter contribution. It has been found that the field-size behaviour of wedge factor measured with full water phantom is similar to that measured with the miniphantom and cap. This indicates that the head scatter radiation is the major contributor to the field size dependence of wedge factors. Wedge factors measured with water phantom are up to 5.0% smaller than those measured with miniphantom. This difference increases with wedge angle. When Measured with the flattening filter removed, the field size dependence of the wedge factor is reduced. This justify that the flattening filter is one of the major contributors to head scatters. The measurement results made with the brass cap agree well with those made by using the miniphantom. By measuring the monitor chamber output, it is found that the backscatters from the wedge into the linac ion chamber have little effect on the field size dependence of the wedge factor

  10. Quench propagation across the copper wedges in SSC dipoles

    International Nuclear Information System (INIS)

    Ghosh, A.K.; Robins, K.E.; Sampson, W.B.

    1986-01-01

    The effect of copper wedges on quench propagation in SSC windings has been studied. The results indicate that the turn-to-turn quench transit time for conductors separated by an insulated copper wedge can be predicted with reasonable accuracy from the bulk quench properties and the mean wedge thickness

  11. Group sequential designs for stepped-wedge cluster randomised trials.

    Science.gov (United States)

    Grayling, Michael J; Wason, James Ms; Mander, Adrian P

    2017-10-01

    The stepped-wedge cluster randomised trial design has received substantial attention in recent years. Although various extensions to the original design have been proposed, no guidance is available on the design of stepped-wedge cluster randomised trials with interim analyses. In an individually randomised trial setting, group sequential methods can provide notable efficiency gains and ethical benefits. We address this by discussing how established group sequential methodology can be adapted for stepped-wedge designs. Utilising the error spending approach to group sequential trial design, we detail the assumptions required for the determination of stepped-wedge cluster randomised trials with interim analyses. We consider early stopping for efficacy, futility, or efficacy and futility. We describe first how this can be done for any specified linear mixed model for data analysis. We then focus on one particular commonly utilised model and, using a recently completed stepped-wedge cluster randomised trial, compare the performance of several designs with interim analyses to the classical stepped-wedge design. Finally, the performance of a quantile substitution procedure for dealing with the case of unknown variance is explored. We demonstrate that the incorporation of early stopping in stepped-wedge cluster randomised trial designs could reduce the expected sample size under the null and alternative hypotheses by up to 31% and 22%, respectively, with no cost to the trial's type-I and type-II error rates. The use of restricted error maximum likelihood estimation was found to be more important than quantile substitution for controlling the type-I error rate. The addition of interim analyses into stepped-wedge cluster randomised trials could help guard against time-consuming trials conducted on poor performing treatments and also help expedite the implementation of efficacious treatments. In future, trialists should consider incorporating early stopping of some kind into

  12. Tax wedge in Croatia, Austria, Hungary, Poland and Greece

    Directory of Open Access Journals (Sweden)

    Marin Onorato

    2016-06-01

    Full Text Available The aim of this paper is to compare the tax burden on labour income in Croatia, Austria, Greece, Hungary and Poland in 2013. The Taxing Wages methodology has been applied to hypothetical units across a range of gross wages in order to calculate net average tax wedge, net average tax rate, as well as other relevant indicators. When it comes to single workers without children, the smallest tax wedge for workers earning less than the average gross wage was found in Croatia, while Poland had the smallest tax wedge for above-average wages. Due to a progressive PIT system, the tax wedge for a single worker in Croatia reaches 50% at 400% of the average gross wage, equalling that of Austria, Greece and Hungary. Tax wedges for couples with two children show a similar trend.

  13. Geology of drill hole USW VH-2, and structure of Crater Flat, southwestern Nevada

    International Nuclear Information System (INIS)

    Carr, W.J.; Parrish, L.D.

    1985-01-01

    A 1219 meter (4000 ft) drill hole in Crater Flat shows the absence of buried Pliocene or Quaternary volcanic rocks, and penetrates a section of Timber Mountain, Paintbrush, and the upper part of the Crater Flat Tuffs, similar to that exposed adjacent to Crater Flat. A prominent negative aeromagnetic anomaly between the drill hole and Bare Mountain is attributed to a westward thickening section of a reversely magnetized Miocene basalt. The relatively shallow depth of this basalt in the west-central part of Crater Flat indicates that no large amount of tectonic movement has occurred in approximately the last 10 m.y. Massive brecciated wedges of Paleozoic rocks are penetrated in two stratigraphic intervals in the drill hole; the older one, between the Tiva Canyon Member of the Paintbrush Tuff and the Rainier Mesa Member of the Timber Mountain Tuff, correlates with the time of maximum faulting east of Crater Flat in the Yucca Mountain area. The younger slide masses are correlated with a large slide block of probable late Miocene age exposed along the southwestern rim of Crater Flat. The structural pattern and style buried beneath central and western Crater Flat is deduced to be similar to that exposed at Yucca Mountain, but less developed. The major fault system controlling the steep east face of Bare Mountain, though probably still active, is believed to have developed mainly as a result of caldera collapse between 13 and 14 m.y. ago. Relations between faulting and four episodes of basalt eruption in the Crater Flat area strongly suggest contemporaneity of the two processes. 17 refs., 2 figs., 3 tabs

  14. Comparison of dosimetric methods for virtual wedge analysis

    International Nuclear Information System (INIS)

    Bailey, M.; Nelson, V.; Collins, O.; West, M.; Holloway, L.; Rajapaske, S.; Arts, J.; Varas, J.; Cho, G.; Hill, R.

    2004-01-01

    Full text: The Siemens Virtual Wedge (Concord, USA) creates wedged beam profile by moving a single collimator jaw across the specified field size whilst varying the dose rate and jaw speed for use in the delivery of radiotherapy treatments. The measurement of the dosimetric characteristics of the Siemens Virtual Wedge poses significant challenges to medical physicists. This study investigates several different methods for measuring and analysing the virtual wedge for data collection for treatment planning systems and ongoing quality assurance. The beam profiles of the Virtual Wedge (VW) were compared using several different dosimetric methods. Open field profiles were measured with Kodak X-Omat V (Rochester, NY, USA) radiographic film and compared with measurements made using the Sun Nuclear Profiler with a Motorized Drive Assembly (MDA) (Melbourne, FL, USA) and the Scanditronix Wellhofer CC13 ionisation chamber and 24 ion Chamber Array (CA24) (Schwarzenbruck, Germany). The resolution of each dosimetric method for open field profiles was determined. The Virtual Wedge profiles were measured with radiographic film the Profiler and the Scanditronix Wellhofer CA 24 ion Chamber Array at 5 different depths. The ease of setup, time taken, analysis and accuracy of measurement were all evaluated to determine the method that would be both appropriate and practical for routine quality assurance of the Virtual Wedge. The open field profiles agreed within ±2% or 2mm for all dosimetric methods. The accuracy of the Profiler and CA24 are limited to half of the step size selected for each of these detectors. For the VW measurements a step size of 2mm was selected for the Profiler and the CA24. The VW profiles for all dosimetric methods agreed within ±2% or 2mm for the main wedged section of the profile. The toe and heel ends of the wedges showed the significant discrepancies dependent upon the dosimetry method used, up to 7% for the toe end with the CA24. The dosimetry of the

  15. Microtopographic control on the ground thermal regime in ice wedge polygons

    Science.gov (United States)

    Abolt, Charles J.; Young, Michael H.; Atchley, Adam L.; Harp, Dylan R.

    2018-06-01

    The goal of this research is to constrain the influence of ice wedge polygon microtopography on near-surface ground temperatures. Ice wedge polygon microtopography is prone to rapid deformation in a changing climate, and cracking in the ice wedge depends on thermal conditions at the top of the permafrost; therefore, feedbacks between microtopography and ground temperature can shed light on the potential for future ice wedge cracking in the Arctic. We first report on a year of sub-daily ground temperature observations at 5 depths and 9 locations throughout a cluster of low-centered polygons near Prudhoe Bay, Alaska, and demonstrate that the rims become the coldest zone of the polygon during winter, due to thinner snowpack. We then calibrate a polygon-scale numerical model of coupled thermal and hydrologic processes against this dataset, achieving an RMSE of less than 1.1 °C between observed and simulated ground temperature. Finally, we conduct a sensitivity analysis of the model by systematically manipulating the height of the rims and the depth of the troughs and tracking the effects on ice wedge temperature. The results indicate that winter temperatures in the ice wedge are sensitive to both rim height and trough depth, but more sensitive to rim height. Rims act as preferential outlets of subsurface heat; increasing rim size decreases winter temperatures in the ice wedge. Deeper troughs lead to increased snow entrapment, promoting insulation of the ice wedge. The potential for ice wedge cracking is therefore reduced if rims are destroyed or if troughs subside, due to warmer conditions in the ice wedge. These findings can help explain the origins of secondary ice wedges in modern and ancient polygons. The findings also imply that the potential for re-establishing rims in modern thermokarst-affected terrain will be limited by reduced cracking activity in the ice wedges, even if regional air temperatures stabilize.

  16. Experimental investigation of sound absorption of acoustic wedges for anechoic chambers

    Science.gov (United States)

    Belyaev, I. V.; Golubev, A. Yu.; Zverev, A. Ya.; Makashov, S. Yu.; Palchikovskiy, V. V.; Sobolev, A. F.; Chernykh, V. V.

    2015-09-01

    The results of measuring the sound absorption by acoustic wedges, which were performed in AC-3 and AC-11 reverberation chambers at the Central Aerohydrodynamic Institute (TsAGI), are presented. Wedges of different densities manufactured from superfine basaltic and thin mineral fibers were investigated. The results of tests of these wedges were compared to the sound absorption of wedges of the operating AC-2 anechoic facility at TsAGI. It is shown that basaltic-fiber wedges have better sound-absorption characteristics than the investigated analogs and can be recommended for facing anechoic facilities under construction.

  17. Diffusion induced flow on a wedge-shaped obstacle

    International Nuclear Information System (INIS)

    Zagumennyi, Ia V; Dimitrieva, N F

    2016-01-01

    In this paper the problem of evolution of diffusion induced flow on a wedge-shaped obstacle is analyzed numerically. The governing set of fundamental equations is solved using original solvers from the open source OpenFOAM package on supercomputer facilities. Due to breaking of naturally existing diffusion flux of a stratifying agent by the impermeable surface of the wedge a complex multi-level vortex system of compensatory fluid motions is formed around the obstacle. Sharp edges of the obstacle generate extended high-gradient horizontal interfaces which are clearly observed in laboratory experiments by high-resolution Schlieren visualization. Formation of an intensive pressure depression zone in front of the leading vertex of the wedge is responsible for generation of propulsive force resulting in a self-displacement of the obstacle along the neutral buoyancy horizon in a stably stratified environment. The size of the pressure deficiency area near the sharp vertex of a concave wedge is about twice that for a convex one. This demonstrates a more intensive propulsion mechanism in case of the concave wedge and, accordingly, a higher velocity of its self-movement in a continuously stratified medium. (paper)

  18. Physichal parameters for wedge filters used in radiotherapy

    International Nuclear Information System (INIS)

    Strunga, Emil

    1995-01-01

    Wedge filters using in radiotherapy up two important problems: attenuation of gamma rays introduced by the presence of wedge filters and spinning of isodoses curves plate. Depending of irradiation geometry, characterised by D w , - source filter distance, D c - source dose's estimate point distance, a - side of irradiation field; nature and size filter: α - wedge angle, μ - linear adsorption coefficient, ε - filter cover attenuation w - filter side, and nature of target volume characterised by μ' - linear absorption coefficient of medium has been estimated absorption factor of wedge filter (k w ) for two irradiation geometry: and spinning angle of isodose plate (Θ): 3) tg θ (μD w (μ'D c - 2 Calculated values has been compared with the experimental measured values, for a cobaltotherapy unit Rokus-M, and the result was that between the two series of dates it is a good concordance

  19. Near-Surface Profiles of Water Stable Isotope Components and Indicated Transitional History of Ice-Wedge Polygons Near Barrow

    Science.gov (United States)

    Iwahana, G.; Wilson, C.; Newman, B. D.; Heikoop, J. M.; Busey, R.

    2017-12-01

    Wetlands associated with ice-wedge polygons are commonly distributed across the Arctic Coastal Plain of northern Alaska, a region underlain by continuous permafrost. Micro-topography of the ice-wedge polygons controls local hydrology, and the micro-topography could be altered due to factors such like surface vegetation, wetness, freeze-thaw cycles, and permafrost degradation/aggradation under climate change. Understanding status of the wetlands in the near future is important because it determines biogeochemical cycle, which drives release of greenhouse gases from the ground. However, transitional regime of the ice-wedge polygons under the changing climate is not fully understood. In this study, we analyzed geochemistry of water extracted from frozen soil cores sampled down to about 1m depth in 2014 March at NGEE-Arctic sites in the Barrow Environmental Observatory. The cores were sampled from troughs/rims/centers of five different low-centered or flat-centered polygons. The frozen cores are divided into 5-10cm cores for each location, thawed in sealed plastic bags, and then extracted water was stored in vials. Comparison between the profiles of geochemistry indicated connection of soil water in the active layer at different location in a polygon, while it revealed that distinctly different water has been stored in permafrost layer at troughs/rims/centers of some polygons. Profiles of volumetric water content (VWC) showed clear signals of freeze-up desiccation in the middle of saturated active layers as low VWC anomalies at most sampling points. Water in the active layer and near-surface permafrost was classified into four categories: ice wedge / fresh meteoric / transitional / highly fractionated water. The overall results suggested prolonged separation of water in the active layer at the center of low-centered polygons without lateral connection in water path in the past.

  20. Generalized monitor unit calculation for the Varian enhanced dynamic wedge field

    International Nuclear Information System (INIS)

    Liu Chihray; Kim, Siyong; Kahler, Darren L.; Palta, Jatinder R.

    2003-01-01

    The generalized monitor unit (MU) calculation equation for the Varian enhanced dynamic wedge (EDW) is derived. The assumption of this MU calculation method is that the wedge factor of the EDW at the center of the field is a function of field size, the position of the center of the field in the wedge direction, and the final position of the moving jaw. The wedge factors at the center of the field in both symmetric and asymmetric fields are examined. The difference between calculated and measured wedge factors is within 1.0%. The method developed here is easy to implement. The only datum required in addition to the standard set of conventional physical wedge implementation data is the off-axis output factor for the open field in the reference condition. The off-center point calculation is also examined. For the off-center point calculation, the dose profile in the wedge direction for the largest EDW field is used to obtain the relative off-center ratio in any smaller wedge field. The accuracy of the off-center point calculation decreases when the point of calculation is too close to the field edge

  1. Isolating active orogenic wedge deformation in the southern Subandes of Bolivia

    Science.gov (United States)

    Weiss, Jonathan R.; Brooks, Benjamin A.; Foster, James H.; Bevis, Michael; Echalar, Arturo; Caccamise, Dana; Heck, Jacob; Kendrick, Eric; Ahlgren, Kevin; Raleigh, David; Smalley, Robert; Vergani, Gustavo

    2016-08-01

    A new GPS-derived surface velocity field for the central Andean backarc permits an assessment of orogenic wedge deformation across the southern Subandes of Bolivia, where recent studies suggest that great earthquakes (>Mw 8) are possible. We find that the backarc is not isolated from the main plate boundary seismic cycle. Rather, signals from subduction zone earthquakes contaminate the velocity field at distances greater than 800 km from the Chile trench. Two new wedge-crossing velocity profiles, corrected for seasonal and earthquake affects, reveal distinct regions that reflect (1) locking of the main plate boundary across the high Andes, (2) the location of and loading rate at the back of orogenic wedge, and (3) an east flank velocity gradient indicative of décollement locking beneath the Subandes. Modeling of the Subandean portions of the profiles indicates along-strike variations in the décollement locked width (WL) and wedge loading rate; the northern wedge décollement has a WL of ~100 km while accumulating slip at a rate of ~14 mm/yr, whereas the southern wedge has a WL of ~61 km and a slip rate of ~7 mm/yr. When compared to Quaternary estimates of geologic shortening and evidence for Holocene internal wedge deformation, the new GPS-derived wedge loading rates may indicate that the southern wedge is experiencing a phase of thickening via reactivation of preexisting internal structures. In contrast, we suspect that the northern wedge is undergoing an accretion or widening phase primarily via slip on relatively young thrust-front faults.

  2. A Wedge Absorber Experiment at MICE

    Energy Technology Data Exchange (ETDEWEB)

    Neuffer, David [Fermilab; Mohayai, Tanaz [IIT, Chicago; Rogers, Chris [Rutherford; Snopok, Pavel [IIT, Chicago; Summers, Don [Mississippi U.

    2017-05-01

    Emittance exchange mediated by wedge absorbers is required for longitudinal ionization cooling and for final transverse emittance minimization for a muon collider. A wedge absorber within the MICE beam line could serve as a demonstration of the type of emittance exchange needed for 6-D cooling, including the configurations needed for muon colliders, as well as configurations for low-energy muon sources. Parameters for this test are explored in simulation and possible experimental configurations with simulated results are presented.

  3. Irradiation of parametria by double-wedge

    International Nuclear Information System (INIS)

    Weisz, Csaba; Katona, Ernoe; Zarand, Pal; Polgar, Istvan; Nemeth, Gyoergy

    1984-01-01

    The dose distribution of a cobalt unit modified with a double-wedge as well as its combination with intracavitary radiotherapy was investigated. The measurements were made in both Alderson-Rando and wather phantom by using film densitometry, thermoluminescence dosimetry and ionization chambers. The dose distribution calculated on the basis of the Van de Geij program was in good agreement with the measurements. A homogeneous irradiation of the parametria can be obtained by using a combination of intracavitary and external double-wedge irradiation. (author)

  4. The Tax Wedge in Slovenia: International Comparison and Policy Recommendations

    Directory of Open Access Journals (Sweden)

    Primož Dolenc

    2005-09-01

    Full Text Available When taxes on labor are introduced, a “tax wedge” appears between the labor costs paid by the employer (gross wage and the net wage received by an employee. At a certain level of wage, a higher tax wedge increases unemployment and decreases employment, all other things being equal. The paper tackles three main questions: the characteristics of the tax wedge, unemployment and employment rates in OECD countries in the recent past, tax wedge policy in the EU15 and the new EU members and the tax system and its effects on the unemployment and employment rates in Slovenia. We found that the OECD countries can be classified into two groups of countries if the tax wedge, the unemployment rate and the employment rate are taken into consideration. The first group is the high tax wedge, high unemployment rate and low employment rate group of countries, whereas the other group has the opposite characteristics. European member states (old and new have on average a higher tax burden on labor than the OECD average, consequently suffering from higher unemployment rates. Slovenia has an unreasonably high tax wedge; in the EU only Belgium and Germany have a higher tax burden. According to previous and our empirical findings we suggest that Slovenia could benefit from a reduction in the tax wedge.

  5. Innovative wedge axe in making split firewood

    International Nuclear Information System (INIS)

    Mutikainen, A.

    1998-01-01

    Interteam Oy, a company located in Espoo, has developed a new method for making split firewood. The tools on which the patented System Logmatic are based are wedge axe and cylindrical splitting-carrying frame. The equipment costs about 495 FIM. The block of wood to be split is placed inside the upright carrying frame and split in a series of splitting actions using the innovative wedge axe. The finished split firewood remains in the carrying frame, which (as its name indicates) also serves as the means for carrying the firewood. This innovative wedge-axe method was compared with the conventional splitting of wood using an axe (Fiskars -handy 1400 splitting axe costing about 200 FIM) in a study conducted at TTS-Institute. There were eight test subjects involved in the study. In the case of the wedge-axe method, handling of the blocks to be split and of the finished firewood was a little quicker, but in actual splitting it was a little slower than the conventional axe method. The average productivity of splitting the wood and of the work stages related to it was about 0.4 m 3 per effective hour in both methods. The methods were also equivalent of one another in terms of the load imposed by the work when measured in terms of the heart rate. As regards work safety, the wedge-axe method was superior to the conventional method, but the continuous striking action and jolting transmitted to the arms were unpleasant (orig.)

  6. Three-dimensional wedge filling in ordered and disordered systems

    International Nuclear Information System (INIS)

    Greenall, M J; Parry, A O; Romero-Enrique, J M

    2004-01-01

    We investigate interfacial structural and fluctuation effects occurring at continuous filling transitions in 3D wedge geometries. We show that fluctuation-induced wedge covariance relations that have been reported recently for 2D filling and wetting have mean-field or classical analogues that apply to higher-dimensional systems. Classical wedge covariance emerges from analysis of filling in shallow wedges based on a simple interfacial Hamiltonian model and is supported by detailed numerical investigations of filling within a more microscopic Landau-like density functional theory. Evidence is presented that classical wedge covariance is also obeyed for filling in more acute wedges in the asymptotic critical regime. For sufficiently short-ranged forces mean-field predictions for the filling critical exponents and covariance are destroyed by pseudo-one-dimensional interfacial fluctuations. We argue that in this filling fluctuation regime the critical exponents describing the divergence of length scales are related to values of the interfacial wandering exponent ζ(d) defined for planar interfaces in (bulk) two-dimensional (d = 2) and three-dimensional (d = 3) systems. For the interfacial height l w ∼ θ-α) -β w , with θ the contact angle and α the wedge tilt angle, we find β w = ζ(2)/2(1-ζ(3)). For pure systems (thermal disorder) we recover the known result β w = 1/4 predicted by interfacial Hamiltonian studies whilst for random-bond disorder we predict the universal critical exponent β ∼ even in the presence of dispersion forces. We revisit the transfer matrix theory of three-dimensional filling based on an effective interfacial Hamiltonian model and discuss the interplay between breather, tilt and torsional interfacial fluctuations. We show that the coupling of the modes allows the problem to be mapped onto a quantum mechanical problem as conjectured by previous authors. The form of the interfacial height probability distribution function predicted by

  7. Optical wedge method for spatial reconstruction of particle trajectories

    International Nuclear Information System (INIS)

    Asatiani, T.L.; Alchudzhyan, S.V.; Gazaryan, K.A.; Zograbyan, D.Sh.; Kozliner, L.I.; Krishchyan, V.M.; Martirosyan, G.S.; Ter-Antonyan, S.V.

    1978-01-01

    A technique of optical wedges allowing the full reconstruction of pictures of events in space is considered. The technique is used for the detection of particle tracks in optical wide-gap spark chambers by photographing in one projection. The optical wedges are refracting right-angle plastic prisms positioned between the camera and the spark chamber so that through them both ends of the track are photographed. A method for calibrating measurements is given, and an estimate made of the accuracy of the determination of the second projection with the help of the optical wedges

  8. SOFTWARE FOR COMPUTER-AIDED DESIGN OF CROSS-WEDGE ROLLING

    OpenAIRE

    A. A. Abramov; S. V. Medvedev

    2013-01-01

    The issues of computer technology creation of 3D-design and engineering analysis of metal forming processes using cross wedge rolling methods (CWR) are considered. The developed software for computer-aided design and simulation of cross-wedge rolling is described.

  9. Three-dimensional vertebral wedging in mild and moderate adolescent idiopathic scoliosis.

    Directory of Open Access Journals (Sweden)

    Sophie-Anne Scherrer

    Full Text Available Vertebral wedging is associated with spinal deformity progression in adolescent idiopathic scoliosis. Reporting frontal and sagittal wedging separately could be misleading since these are projected values of a single three-dimensional deformation of the vertebral body. The objectives of this study were to determine if three-dimensional vertebral body wedging is present in mild scoliosis and if there are a preferential vertebral level, position and plane of deformation with increasing scoliotic severity.Twenty-seven adolescent idiopathic scoliotic girls with mild to moderate Cobb angles (10° to 50° participated in this study. All subjects had at least one set of bi-planar radiographs taken with the EOS® X-ray imaging system prior to any treatment. Subjects were divided into two groups, separating the mild (under 20° from the moderate (20° and over spinal scoliotic deformities. Wedging was calculated in three different geometric planes with respect to the smallest edge of the vertebral body.Factorial analyses of variance revealed a main effect for the scoliosis severity but no main effect of vertebral Levels (apex and each of the three vertebrae above and below it (F = 1.78, p = 0.101. Main effects of vertebral Positions (apex and above or below it (F = 4.20, p = 0.015 and wedging Planes (F = 34.36, p<0.001 were also noted. Post-hoc analysis demonstrated a greater wedging in the inferior group of vertebrae (3.6° than the superior group (2.9°, p = 0.019 and a significantly greater wedging (p≤0.03 along the sagittal plane (4.3°.Vertebral wedging was present in mild scoliosis and increased as the scoliosis progressed. The greater wedging of the inferior group of vertebrae could be important in estimating the most distal vertebral segment to be restrained by bracing or to be fused in surgery. Largest vertebral body wedging values obtained in the sagittal plane support the claim that scoliosis could be initiated

  10. Two brittle ductile transitions in subduction wedges, as revealed by topography

    Science.gov (United States)

    Thissen, C.; Brandon, M. T.

    2013-12-01

    Subduction wedges contain two brittle ductile transitions. One transition occurs within the wedge interior, and a second transition occurs along the decollement. The decollement typically has faster strain rates, which suggests that the brittle ductile transition along the decollement will be more rearward (deeper) than the transition within the interior. However, the presence of distinct rheologies or other factors such as pore fluid pressure along the decollement may reverse the order of the brittle-ductile transitions. We adopt a solution by Williams et al., (1994) to invert for these brittle ductile transitions using the wedge surface topography. At present, this model does not include an s point or sediment loading atop the wedge. The Hellenic wedge, however, as exposed in Crete presents an ideal setting to test these ideas. We find that the broad high of the Mediterranean ridge represents the coulomb frictional part of the Hellenic wedge. The rollover in topography north of the ridge results from curvature of the down going plate, creating a negative alpha depression in the vicinity of the Strabo, Pliny, and Ionian 'troughs' south of Crete. A steep topographic rise out of these troughs and subsequent flattening reflects the brittle ductile transition at depth in both the decollement and the wedge interior. Crete exposes the high-pressure viscous core of the wedge, and pressure solution textures provide additional evidence for viscous deformation in the rearward part of the wedge. The location of the decollement brittle ductile transition has been previously poorly constrained, and Crete has never experienced a subduction zone earthquake in recorded history. Williams, C. A., et al., (1994). Effect of the brittle ductile transition on the topography of compressive mountain belts on Earth and Venus. Journal of Geophysical Research Solid Earth

  11. On the practice of the clinical implementation of enhanced dynamic wedges

    International Nuclear Information System (INIS)

    Koken, Phil W.; Heukelom, Stan; Cuijpers, Johan P.

    2003-01-01

    Practical aspects of the clinical implementation of enhanced dynamic wedges (EDW) replacing manual wedges are presented and discussed extensively. A comparison between measured and calculated data is also presented. Relative dose distributions and wedge factors were calculated with a commercially available treatment planning system and measured in a water-phantom and with an ionization chamber. Wedge factor calculations and measurements were also compared with an independent method of wedge factor calculations available from the literature. Aspects of the clinical implementation, such as safety and quality assurance, were evaluated. Measurements and calculations agreed very well and were slightly better than results of previous studies. Profiles and percentage depth doses (PDDs) agreed within 1% to 1.5% and within 0.5%, respectively. Measured and calculated wedge factors ratios agreed within 0.5% to 1%. Calculated and measured EDW dose distributions showed excellent agreement, both relative and absolute. However, for safe and practical use, specific aspects need to be taken into consideration. Once the treatment planning system is commissioned properly, the clinical implementation of EDW is rather straightforward

  12. Analysis of surface and build up region dose for motorized wedge and omni wedge

    International Nuclear Information System (INIS)

    Panta, Raj Kumar; Sundarum, T.

    2008-01-01

    Megavoltage x-ray beam exhibits the well known phenomenon of dose build-up within the first few millimeters of incident phantom surface or skin. The skin sparing effect of high energy gamma or x-ray photon may be reduced or even lost, if the beam is contaminated with electron or low energy photons. Since skin dose in the treatment of deeply seated tumor may be a limiting factor in the delivery of tumoricidal dose due to possible complications such as erythema, desquamation, fibrosis, necrosis and epilation, the dose distribution in the build up region should be known. The objective of this study was to measure and investigate the surface and build-up region dose for 6 MV and 15 MV photon beam for Motorized wedge and Omni wedge in Precise Digital Linear Accelerator (Elekta)

  13. Wedges of Anxiety

    DEFF Research Database (Denmark)

    Hellström, Maria; Brandt, Eva

    2005-01-01

    The Heraclitian notion of a reality in constant flux seems to have settled even in the public consciousness. We are, to an ever-increasing extent, on the move; in motion between different places of abode, between domiciles and places of residence, between temporary addresses and provisory settlem...... cones of light, as the cut their way into the unknown, like wedges of anxiety...

  14. Employment and productivity: The role of the tax wedge

    Directory of Open Access Journals (Sweden)

    Andrea FESTA

    2015-11-01

    Full Text Available After the economic crisis, many countries aim at reducing unemployment and foster productivity. To address these issues one of the most common policy indications recommends lowering the tax wedge on labour in order to increase employment and growth. As a consequence, a review of the empirical studies focused on the relation between tax wedge, employment and productivity is an useful and demanding exercise, especially in those European countries where the topic is on the front page of the domestic policy debate because the productivity growth is low and the tax wedge on labour is high.

  15. Casimir effect for a semitransparent wedge and an annular piston

    International Nuclear Information System (INIS)

    Milton, Kimball A.; Wagner, Jef; Kirsten, Klaus

    2009-01-01

    We consider the Casimir energy due to a massless scalar field in a geometry of an infinite wedge closed by a Dirichlet circular cylinder, where the wedge is formed by δ-function potentials, so-called semitransparent boundaries. A finite expression for the Casimir energy corresponding to the arc and the presence of both semitransparent potentials is obtained, from which the torque on the sidewalls can be derived. The most interesting part of the calculation is the nontrivial nature of the angular mode functions. Numerical results are obtained which are closely analogous to those recently found for a magnetodielectric wedge, with the same speed of light on both sides of the wedge boundaries. Alternative methods are developed for annular regions with radial semitransparent potentials, based on reduced Green's functions for the angular dependence, which allows calculations using the multiple-scattering formalism. Numerical results corresponding to the torque on the radial plates are likewise computed, which generalize those for the wedge geometry. Generally useful formulas for calculating Casimir energies in separable geometries are derived.

  16. Are Pericentric Inversions Reorganizing Wedge Shell Genomes?

    Directory of Open Access Journals (Sweden)

    Daniel García-Souto

    2017-12-01

    Full Text Available Wedge shells belonging to the Donacidae family are the dominant bivalves in exposed beaches in almost all areas of the world. Typically, two or more sympatric species of wedge shells differentially occupy intertidal, sublittoral, and offshore coastal waters in any given locality. A molecular cytogenetic analysis of two sympatric and closely related wedge shell species, Donax trunculus and Donax vittatus, was performed. Results showed that the karyotypes of these two species were both strikingly different and closely alike; whilst metacentric and submetacentric chromosome pairs were the main components of the karyotype of D. trunculus, 10–11 of the 19 chromosome pairs were telocentric in D. vittatus, most likely as a result of different pericentric inversions. GC-rich heterochromatic bands were present in both species. Furthermore, they showed coincidental 45S ribosomal RNA (rRNA, 5S rRNA and H3 histone gene clusters at conserved chromosomal locations, although D. trunculus had an additional 45S rDNA cluster. Intraspecific pericentric inversions were also detected in both D. trunculus and D. vittatus. The close genetic similarity of these two species together with the high degree of conservation of the 45S rRNA, 5S rRNA and H3 histone gene clusters, and GC-rich heterochromatic bands indicate that pericentric inversions contribute to the karyotype divergence in wedge shells.

  17. Multiple phases and vicious walkers in a wedge

    Directory of Open Access Journals (Sweden)

    Gesualdo Delfino

    2015-12-01

    Full Text Available We consider a statistical system in a planar wedge, for values of the bulk parameters corresponding to a first order phase transition and with boundary conditions inducing phase separation. Our previous exact field theoretical solution for the case of a single interface is extended to a class of systems, including the Blume–Capel model as the simplest representative, allowing for the appearance of an intermediate layer of a third phase. We show that the interfaces separating the different phases behave as trajectories of vicious walkers, and determine their passage probabilities. We also show how the theory leads to a remarkable form of wedge covariance, i.e. a relation between properties in the wedge and in the half plane, which involves the appearance of self-Fourier functions.

  18. Surface Geophysical Measurements for Locating and Mapping Ice-Wedges

    DEFF Research Database (Denmark)

    Ingeman-Nielsen, Thomas; Tomaskovicova, Sonia; Larsen, S.H.

    2012-01-01

    to test the applicability of DC electrical resistivity tomography (ERT) and Ground Penetrating Radar (GPR) to identifying and mapping ice-wedge occurrences. The site is located in Central West Greenland, and the ice-wedges are found in a permafrozen peat soil with an active layer of about 30 cm. ERT...

  19. Dissolved organic carbon loss from Yedoma permafrost amplified by ice wedge thaw

    International Nuclear Information System (INIS)

    Vonk, J E; Mann, P J; Spencer, R G M; Bulygina, E B; Holmes, R M; Dowdy, K L; Davydova, A; Davydov, S P; Zimov, N; Eglinton, T I

    2013-01-01

    Pleistocene Yedoma permafrost contains nearly a third of all organic matter (OM) stored in circum-arctic permafrost and is characterized by the presence of massive ice wedges. Due to its rapid formation by sediment accumulation and subsequent frozen storage, Yedoma OM is relatively well preserved and highly biologically available (biolabile) upon thaw. A better understanding of the processes regulating Yedoma degradation is important to improve estimates of the response and magnitude of permafrost carbon feedbacks to climate warming. In this study, we examine the composition of ice wedges and the influence of ice wedge thaw on the biolability of Yedoma OM. Incubation assays were used to assess OM biolability, fluorescence spectroscopy to characterize the OM composition, and potential enzyme activity rates to examine the controls and regulation of OM degradation. We show that increasing amounts of ice wedge melt water in Yedoma-leached incubations enhanced the loss of dissolved OM over time. This may be attributed to the presence of low-molecular weight compounds and low initial phenolic content in the OM of ice wedges, providing a readily available substrate that promotes the degradation of Yedoma OC. The physical vulnerability of ice wedges upon thaw (causing irreversible collapse), combined with the composition of ice wedge-engrained OM (co-metabolizing old OM), underlines the particularly strong potential of Yedoma to generate a positive feedback to climate warming relative to other forms of non-ice wedge permafrost. (letter)

  20. Degradation and stabilization of ice wedges: Implications for assessing risk of thermokarst in northern Alaska

    Science.gov (United States)

    Kanevskiy, Mikhail; Shur, Yuri; Jorgenson, Torre; Brown, Dana R. N.; Moskalenko, Nataliya; Brown, Jerry; Walker, Donald A.; Raynolds, Martha K.; Buchhorn, Marcel

    2017-11-01

    Widespread degradation of ice wedges has been observed during the last decades in numerous areas within the continuous permafrost zone of Eurasia and North America. To study ice-wedge degradation, we performed field investigations at Prudhoe Bay and Barrow in northern Alaska during 2011-2016. In each study area, a 250-m transect was established with plots representing different stages of ice-wedge degradation/stabilization. Field work included surveying ground- and water-surface elevations, thaw-depth measurements, permafrost coring, vegetation sampling, and ground-based LiDAR scanning. We described cryostratigraphy of frozen soils and stable isotope composition, analyzed environmental characteristics associated with ice-wedge degradation and stabilization, evaluated the vulnerability and resilience of ice wedges to climate change and disturbances, and developed new conceptual models of ice-wedge dynamics that identify the main factors affecting ice-wedge degradation and stabilization and the main stages of this quasi-cyclic process. We found significant differences in the patterns of ice-wedge degradation and stabilization between the two areas, and the patterns were more complex than those previously described because of the interactions of changing topography, water redistribution, and vegetation/soil responses that can interrupt or reinforce degradation. Degradation of ice wedges is usually triggered by an increase in the active-layer thickness during exceptionally warm and wet summers or as a result of flooding or disturbance. Vulnerability of ice wedges to thermokarst is controlled by the thickness of the intermediate layer of the upper permafrost, which overlies ice wedges and protects them from thawing. In the continuous permafrost zone, degradation of ice wedges rarely leads to their complete melting; and in most cases wedges eventually stabilize and can then resume growing, indicating a somewhat cyclic and reversible process. Stabilization of ice wedges

  1. Evaluation method of lead measurement accuracy of gears using a wedge artefact

    International Nuclear Information System (INIS)

    Komori, Masaharu; Takeoka, Fumi; Kubo, Aizoh; Okamoto, Kazuhiko; Osawa, Sonko; Sato, Osamu; Takatsuji, Toshiyuki

    2009-01-01

    The reduction of the vibration and noise of gears is an important issue in mechanical devices such as vehicles and wind turbines. The characteristics of the vibration and noise of gears are markedly affected by deviations of the tooth flank form of micrometre order; therefore, a strict quality control of the tooth flank form is required. The accuracy of the lead measurement for a gear-measuring instrument is usually evaluated using a master gear or a lead master. However, it is difficult to manufacture masters with high accuracy because the helix is a complicated geometrical form. In this paper, we propose a method of evaluating a gear-measuring instrument using a wedge artefact, which includes a highly precise plane surface. The concept of the wedge artefact is described and a mathematical model of the measuring condition of the wedge artefact is constructed. Theoretical measurement results for the wedge artefact are calculated. The wedge artefact is designed and produced on the basis of the theoretical measurement results. A measurement experiment using the wedge artefact is carried out and its effectiveness is verified

  2. Chemical risk factors responsible for the formation of wedge-shaped lesions

    Directory of Open Access Journals (Sweden)

    Perić Dejan

    2015-01-01

    Full Text Available Introduction: Non-carious tooth substances loss pose a major health problem of a modern man. The literature often collectively describes all non-carious lesions and is therefore difficult to compare results obtained by different authors. Chemical factors are one of the predisposing factors responsible for the formation of wedge-shaped erosions. Aim: Examination of chemical risk factors as one of the predisposing causes responsible for the formation of wedge-shaped lesions. Method: We examined 62 patients with wedge-shaped erosions (mean age 45.52 ± 12.03 years, 58.1% of men and 60 patients without erosions in the control group (mean age 34.40 ± 9.28 years, 60% men . The entire examination was completed by using a questionnaire at the Dental Clinic of the University of Pristina - Kosovska Mitrovica. salivary pH was measured by the pH meter. Results: The results show that the wedge-shaped lesions often occur equally in both men and women. Considerably often it might appear in older people but can also occur in teenagers. Patients with wedge-shaped erosion have increased acidity of saliva, a heightened sense of acid in the mouth and consume a lot more carbonated drinks compared to patients without erosions. Conclusion: Wedge-shaped lesions are more common in people older than 40 years. Taking into account the results obtained in this study it can be concluded that the chemical risk factors truly fall within the predisposing factors that may be responsible for the creation of wedge-shaped erosions.

  3. Variation in Depth Dose Data between Open and Wedge Fields for 6 MV X-Rays

    International Nuclear Information System (INIS)

    U, Hong; Ryu, M. S. Samuel; Park, In Kyu

    1989-01-01

    Central axis depth dose data for 6 MV X-rays, including tissue maximum ratios, were measured for wedge fields according to Tatcher equation. In wedge fields, the differences in magnitude which increased with depth, field size, and wedge thickness increased when compared with the corresponding open field data. However, phantom scatter correction factors for wedge fields differed less that 1% from the corresponding open field factors. The differences in central axis percent depth dose between two types of fields indicated beam hardening by the wedge filter. The deviation of percent depth doses and scatter correction factors between the effective wedge field and the nominal wedge field at same angle was negligible. The differences were less than 3.26% between the nominal or effective wedge fields and the open fields for percent depth doses to the depth 7cm in 6cm x 6cm field. For larger (10cm x 10cm) field size, however, the deviation of percent depth doses between the nominal or effective wedge fields and the open fields were greater-dosimetric errors were 3.56% at depth 7cm and nearly 5.30% at 12cm. We suggest that the percent depth doses of individual wedge and wedge transmission factors should be considered for the dose calculation or monitor setting in the treatment of deep seated tumor

  4. Effects of laterally wedged insoles on symptoms and disease progression in medial knee osteoarthritis: a protocol for a randomised, double-blind, placebo controlled trial

    Directory of Open Access Journals (Sweden)

    Osborne Richard

    2007-09-01

    Full Text Available Abstract Background Whilst laterally wedged insoles, worn inside the shoes, are advocated as a simple, inexpensive, non-toxic self-administered intervention for knee osteoarthritis (OA, there is currently limited evidence to support their use. The aim of this randomised, double-blind controlled trial is to determine whether laterally wedges insoles lead to greater improvements in knee pain, physical function and health-related quality of life, and slower structural disease progression as well as being more cost-effective, than control flat insoles in people with medial knee OA. Methods/Design Two hundred participants with painful radiographic medial knee OA and varus malalignment will be recruited from the community and randomly allocated to lateral wedge or control insole groups using concealed allocation. Participants will be blinded as to which insole is considered therapeutic. Blinded follow up assessment will be conducted at 12 months after randomisation. The outcome measures are valid and reliable measures recommended for OA clinical trials. Questionnaires will assess changes in pain, physical function and health-related quality-of-life. Magnetic resonance imaging will measure changes in tibial cartilage volume. To evaluate cost-effectiveness, participants will record the use of all health-related treatments in a log-book returned to the assessor on a monthly basis. To test the effect of the intervention using an intention-to-treat analysis, linear regression modelling will be applied adjusting for baseline outcome values and other demographic characteristics. Discussion Results from this trial will contribute to the evidence regarding the effectiveness of laterally wedged insoles for the management of medial knee OA. Trial registration ACTR12605000503628; NCT00415259.

  5. Numerical Study on Critical Wedge Angle of Cellular Detonation Reflections

    International Nuclear Information System (INIS)

    Gang, Wang; Kai-Xin, Liu; De-Liang, Zhang

    2010-01-01

    The critical wedge angle (CWA) for the transition from regular reflection (RR) to Mach reflection (MR) of a cellular detonation wave is studied numerically by an improved space-time conservation element and solution element method together with a two-step chemical reaction model. The accuracy of that numerical way is verified by simulating cellular detonation reflections at a 19.3° wedge. The planar and cellular detonation reflections over 45°–55° wedges are also simulated. When the cellular detonation wave is over a 50° wedge, numerical results show a new phenomenon that RR and MR occur alternately. The transition process between RR and MR is investigated with the local pressure contours. Numerical analysis shows that the cellular structure is the essential reason for the new phenomenon and the CWA of detonation reflection is not a certain angle but an angle range. (fundamental areas of phenomenology(including applications))

  6. Localization of observables in the Rindler wedge

    Science.gov (United States)

    Asorey, M.; Balachandran, A. P.; Marmo, G.; de Queiroz, A. R.

    2017-11-01

    One of the striking features of QED is that charged particles create a coherent cloud of photons. The resultant coherent state vectors of photons generate a nontrivial representation of the localized algebra of observables that do not support a representation of the Lorentz group: Lorentz symmetry is spontaneously broken. We show in particular that Lorentz boost generators diverge in this representation, a result shown also by Balachandran et al. [Eur. Phys. J. C 75, 89 (2015), 10.1140/epjc/s10052-015-3305-0] (see also the work by Balachandran et al. [Mod. Phys. Lett. A 28, 1350028 (2013), 10.1142/S0217732313500284]. Localization of observables, for example in the Rindler wedge, uses Poincaré invariance in an essential way [Int. J. Geom. Methods Mod. Phys. 14, 1740008 (2017)., 10.1142/S0219887817400084]. Hence, in the presence of charged fields, the photon observables cannot be localized in the Rindler wedge. These observations may have a bearing on the black hole information loss paradox, as the physics in the exterior of the black hole has points of resemblance to that in the Rindler wedge.

  7. Pilot production of the wedge filter for the TBI (total body irradiation)

    International Nuclear Information System (INIS)

    Ikezaki, Hiromi; Ikeda, Ikuo; Maruyama, Yasushi; Nako, Yasunobu; Tonari, Ayako; Kusuda, Junko; Takayama, Makoto

    2007-01-01

    Total body irradiation (TBI) is performed by various methods, such as a long SSD method and a translational couch method. For patient safety in carrying out TBI, the patient should be placed on the supine position and prone position near the floor. TBI is performed from 2 opposite ports (AP/PA) with a linear accelerator (10 MV X-ray). We experimented with a wedge filter for TBI created by us, which makes dose distribution to a floor uniform. The wedge filter, made of iron alloy, was attached to the linear accelerator. In designing the wedge filter, thickness of the lead-made wedge filter can be calculated numerically from the ratio of linear attenuation coefficient of iron alloy and lead. In measuring the dose profile for a phantom of 20 cm thick, dose homogeneity less than 10% was proved by the wedge filter for TBI. (author)

  8. Contemporary sand wedge development in seasonally frozen ground and paleoenvironmental implications

    Science.gov (United States)

    Wolfe, Stephen A.; Morse, Peter D.; Neudorf, Christina M.; Kokelj, Steven V.; Lian, Olav B.; O'Neill, H. Brendan

    2018-05-01

    Contemporary sand wedges and sand veins are active in seasonally frozen ground within the extensive discontinuous permafrost zone in Northwest Territories, Canada. The region has a subarctic continental climate with 291 mm a-1 precipitation, -4.1 °C mean annual air temperature, warm summers (July mean 17.0 °C), and cold winters (January mean -26.6 °C). Five years of continuous observations indicate that interannual variation of the ground thermal regime is dominantly controlled by winter air temperature and snow cover conditions. At sandy sites, thin snow cover and high thermal conductivity promote rapid freezing, high rates of ground cooling, and low near-surface ground temperatures (-15 to -25 °C), resulting in thermal contraction cracking to depths of 1.2 m. Cracking potentials are high in sandy soils when air temperatures are air temperatures are ≤-17 °C, and snow cover is conditions in peatlands maintain permafrost, but thermal contraction cracking does not occur because thicker snow cover and the thermal properties of peat prolong freezeback and maintain higher winter ground temperatures. A combination of radiocarbon dating, optical dating, and stratigraphic observations were used to differentiate sand wedge types and formation histories. Thermal contraction cracks that develop in the sandy terrain are filled by surface (allochthonous) and/or host (autochthonous) material during the thaw season. Epigenetic sand wedges infilled with allochthonous sand develop within former beach sediments beneath an active eolian sand sheet. Narrower and deeper syngenetic wedges developed within aggrading eolian sand sheets, whereas wider and shallower antisyngenetic wedges developed in areas of active erosion. Thermal contraction cracking beneath vegetation-stabilized surfaces leads to crack infilling by autochthonous host and overlying organic material, with resultant downturning and subsidence of adjacent strata. Sand wedge development in seasonally frozen ground

  9. Computed tomographic findings of intrahepatic peripheral cholangiocarcinoma

    International Nuclear Information System (INIS)

    Woo, Seong Ku; Suh, Soo Jhi; Kim, Ho Joon; Chun, Byung Hee

    1986-01-01

    Cholangiocarcinoma is synonymous with bile duct carcinoma, and can originate in a small intrahepatic bile duct (peripheral type), a major intrahepatic duct including the hepatic hills, an extrahepatic duct, or near the papilla of Vater (central type). In a sense bile duct carcinoma of the peripheral type is cholangiocarcinoma of the liver; it has the same gross configuration as hepatocellular carcinoma, resulting in difficulty to differentiate on the CT. The authors studied CT findings of 14 cases of pathologically proven peripheral type cholangiocarcinoma of the liver during the last 4 years. The results were as follows: 1. Of 14 cases, 8 were female and 6 were male, and the age ranged from 5th to 7th decades. 2. Preoperative clinical diagnosis were as follows: hepatoma 8 cases, abscess 5 cases and metastasis 1 case in order of frequency. 3. Diagnosis were confirmed by hepatic lobectomy in 7 cases, wedge resection in 5 cases and needle biopsy in 2 case. 4. Laboratory findings were not specific, but there were only 2 cases with elevated alpha-fetoprotein level. 5. Associated diseases were gallstones in 1 case, intrahepatic duct stones in 1 case, extrahepatic duct stones in 2 cases, acute or chronic cholecystitis in 5 cases and CS in 3 cases. 6. Angiographic and scintigraphic findings were helpful in differential diagnosis from hepatoma but ultrasonography was non-specific. 7. The number of tumor were solitary in 12 cases and multiple in 2 cases. Among solitary cases, the site of involvement of the liver were right lobe in 8 cases and left lobe in 4 cases. 8. Common CT features of the intrahepatic peripheral cholangiocinoma of the liver were irregular, inhomogeneous, occasionally peripherally enhancing, low density liver mass, frequently accompanied by diffuse or segmental dilatation of the intrahepatic bile duct. If there were normal alpha fetoprotein level, positive skin and/or stool examination for CS and diffuse or segmental dilatation of the intrahepatic duct

  10. The effect of shoe design and lateral wedging on knee loading

    DEFF Research Database (Denmark)

    Mølgaard, Carsten; Kersting, Uwe G.

    The increasing number of patients with developing osteoarthritis is accompanied by a growing scientific interest in non-operative early treatment strategies. It is generally believed that laterally wedged insoles can change the distribution of the knee loading, but the importance of footwear design...... shoe were revealed. Conclusion: Lateral wedging is effective regardless of shoe design. Differences between the four neutral walking conditions underline the importance of footwear choice in individuals. It is safe to apply lateral wedges without jeopardizing muscular control during walking regardless...

  11. Wedge gate valves selecting essentials in pipeline systems designing based on permissible operation parameters

    Science.gov (United States)

    Zakirnichnaya, M. M.; Kulsharipov, I. M.

    2017-10-01

    Wedge gate valves are widely used at the fuel and energy complex enterprises. The pipeline valves manufacturers indicate the safe operation resource according to the current regulatory and technical documentation. In this case, the resource value of the valve body strength calculation results is taken into consideration as the main structural part. However, it was determined that the wedge gate valves fail before the assigned resource due to the occurrence of conditions under which the wedge breaks in the hooks and, accordingly, the sealing integrity is not ensured. In this regard, it became necessary to assess the conditions under which the resource should be assigned not only to the valve body, but also to take into account the wedge durability. For this purpose, wedge resource calculations were made using the example of ZKL2 250-25 and ZKL2 300-25 valves using the ABAQUS software package FE-SAFE module under the technological parameters influence on the basis of their stressstrain state calculation results. Operating conditions, under which the wedge resource value is lower than the one set by the manufacturer, were determined. A technique for limiting the operating parameters for ensuring the wedge durability during the wedge gate valve assigned resource is proposed.

  12. Pleural Dye Marking Using Radial Endobronchial Ultrasound and Virtual Bronchoscopy before Sublobar Pulmonary Resection for Small Peripheral Nodules.

    Science.gov (United States)

    Lachkar, Samy; Baste, Jean-Marc; Thiberville, Luc; Peillon, Christophe; Rinieri, Philippe; Piton, Nicolas; Guisier, Florian; Salaun, Mathieu

    2018-01-01

    Minimally invasive surgery of pulmonary nodules allows suboptimal palpation of the lung compared to open thoracotomy. The objective of this study was to assess endoscopic pleural dye marking using radial endobronchial ultrasound (r-EBUS) and virtual bronchoscopy to localize small peripheral lung nodules immediately before minimally invasive resection. The endoscopic procedure was performed without fluoroscopy, under general anesthesia in the operating room immediately before minimally invasive surgery. Then, 1 mL of methylene blue (0.5%) was instilled into the guide sheath, wedged in the subpleural space. Wedge resection or segmentectomy were guided by visualization of the dye on the pleural surface. Contribution of dye marking to the surgical procedure was rated by the surgeon. Twenty-five nodules, including 6 ground glass opacities, were resected in 22 patients by video-assisted thoracoscopic wedge resection (n = 11) or robotic-assisted thoracoscopic surgery (10 segmentectomies and 1 wedge resection). The median greatest diameter of nodules was 8 mm. No conversion to open thoracotomy was needed. The endoscopic procedure added an average 10 min to surgical resection. The dye was visible on the pleural surface in 24 cases. Histological diagnosis and free margin resection were obtained in all cases. Median skin-to-skin operating time was 90 min for robotic segmentectomy and 40 min for video-assisted wedge resection. The same operative precision was considered impossible by the surgeon without dye marking in 21 cases. Dye marking using r-EBUS and virtual bronchoscopy can be easily and safely performed to localize small pulmonary nodules immediately before minimally invasive resection. © 2018 S. Karger AG, Basel.

  13. Modeling and Stability Analysis of Wedge Clutch System

    Directory of Open Access Journals (Sweden)

    Jian Yao

    2014-01-01

    Full Text Available A wedge clutch with unique features of self-reinforcement and small actuation force was designed. Its self-reinforcement feature, associated with different factors such as the wedge angle and friction coefficient, brings different dynamics and unstable problem with improper parameters. To analyze this system, a complete mathematical model of the actuation system is built, which includes the DC motor, the wedge mechanism, and the actuated clutch pack. By considering several nonlinear factors, such as the slip-stick friction and the contact or not of the clutch plates, the system is piecewise linear. Through the stability analysis of the linearized system in clutch slipping phase, the stable condition of the designed parameters is obtained as α>arctan⁡(μc. The mathematical model of the actuation system is validated by prototype testing. And with the validated model, the system dynamics in both stable and unstable conditions is investigated and discussed in engineering side.

  14. Porous Titanium Wedges in Lateral Column Lengthening for Adult-Acquired Flatfoot Deformity.

    Science.gov (United States)

    Moore, Spencer H; Carstensen, S Evan; Burrus, M Tyrrell; Cooper, Truitt; Park, Joseph S; Perumal, Venkat

    2017-10-01

    Lateral column lengthening (LCL) is a common procedure for reconstruction of stage II flexible adult-acquired flatfoot deformity (AAFD). The recent development of porous titanium wedges for this procedure provides an alternative to allograft and autograft. The purpose of this study was to report radiographic and clinical outcomes achieved with porous titanium wedges in LCL. A retrospective analysis of 34 feet in 30 patients with AAFD that received porous titanium wedges for LCL from January 2011 to October 2014. Deformity correction was assessed using both radiographic and clinical parameters. Radiographic correction was assessed using the lateral talo-first metatarsal angle, the talonavicular uncoverage percentage, and the first metatarsocuneiform height. The hindfoot valgus angle was measured. Patients were followed from a minimum of 6 months up to 4 years (mean 16.1 months). Postoperative radiographs demonstrated significant correction in all 3 radiographic criteria and the hindfoot valgus angle. We had no cases of nonunion, no wedge migration, and no wedges have been removed to date. The most common complication was calcaneocuboid joint pain (14.7%). Porous titanium wedges in LCL can achieve good radiographic and clinical correction of AAFD with a low rate of nonunion and other complications. Level IV: Case series.

  15. Capillary surfaces in a wedge: Differing contact angles

    Science.gov (United States)

    Concus, Paul; Finn, Robert

    1994-01-01

    The possible zero-gravity equilibrium configurations of capillary surfaces u(x, y) in cylindrical containers whose sections are (wedge) domains with corners are investigated mathematically, for the case in which the contact angles on the two sides of the wedge may differ. In such a situation the behavior can depart in significant qualitative ways from that for which the contact angles on the two sides are the same. Conditions are described under which such qualitative changes must occur. Numerically computed surfaces are depicted to indicate the behavior.

  16. Triangular metal wedges for subwavelength plasmon-polariton guiding at telecom wavelengths

    DEFF Research Database (Denmark)

    Boltasseva, Alexandra; Volkov, V.S.; Nielsen, Rasmus Bundgaard

    2008-01-01

    We report on subwavelength plasmon-polariton guiding by triangular metal wedges at telecom wavelengths. A high-quality fabrication procedure for making gold wedge waveguides, which is also mass- production compatible offering large-scale parallel fabrication of plasmonic components, is developed...

  17. Pilot Study: Foam Wedge Chin Support Static Tolerance Testing

    Science.gov (United States)

    2017-10-24

    AFRL-SA-WP-SR-2017-0026 Pilot Study: Foam Wedge Chin Support Static Tolerance Testing Austin M. Fischer, BS1; William W...COVERED (From – To) April – October 2017 4. TITLE AND SUBTITLE Pilot Study: Foam Wedge Chin Support Static Tolerance Testing 5a. CONTRACT NUMBER...PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) USAF School of Aerospace

  18. Analogue modeling of rotational orogenic wedges: implications for the Neogene structural evolution of the Southern Central Andes (33°-35°S)

    Science.gov (United States)

    Herrera, S. S.; Farías, M.; Pinto, L.; Yagupsky, D. L.; Guzman, C.; Charrier, R.

    2017-12-01

    Structural evolution of the southernmost Central Andes is a major subject of debate. Overall vergence within the range and how intra-continental subduction prompts Andean orogeny are controversial topics. Between 33°-35° S, strike of the western slope main structures shifts southwards, from N-S to NNE-SSW, defining the Maipo Orocline. Likely, width of the Principal Cordillera increases southwards. Despite, a progressive southward decrease in orogenic volume has been determined for the segment. To understand such latitudinal variations, and to provide explanations for overall vergence, we carry out analogue models of contractional wedges to explore upper-crustal thrust system development with a progressive variation of the convergence vector. The model setup consisted of a fixed plate on which a mobile plate generated a velocity discontinuity. The upper-crust was simulated using low-cohesive quartz sand. The mobile plate was fixed at its northern end to a pivot, thus progressively incrementing shortening and the obliquity of convergence southwards. PIV photogrammetry recorded wedge evolution. A classical doubly-vergent wedge was formed, consisting of a steep 35° dipping, static thrust on the retro-side, an uplifted core, and an incipient forward-breaking, 25° critically tapered imbricated thrust fan on the pro-side, wider (in plan-view) where the imposed shortening reached the maximum. The resulting wedge is reminiscent of: the steep western Andean slope, in which the bordering thrust has maintained its present position during the Neogene; and the east-vergent fold-and-thrust belt of the eastern slope. The asymmetrical doubly vergence of the model suggests west-directed subduction of the South American continent beneath the orogen. The southward width increase is geometrically comparable to the natural analogue, yet we observe a flat contrast with orogenic shortening and volume estimates for the region. This can be attributed to the fact that uplift and erosion

  19. Late Holocene ice wedges near Fairbanks, Alaska, USA: Environmental setting and history of growth

    Science.gov (United States)

    Hamilton, T.D.; Ager, T.A.; Robinson, S.W.

    1983-01-01

    Test trenches excavated into muskeg near Fairbanks in 1969 exposed a polygonal network of active ice wedges. The wedges occur in peat that has accumulated since about 3500 yr BP and have grown episodically as the permafrost table fluctuated in response to fires, other local site conditions and perhaps regional climatic changes. Radiocarbon dates suggest one or two episodes of ice-wedge growth between about 3500 and 2000 yr BP as woody peat accumulated at the site. Subsequent wedge truncation evidently followed a fire that charred the peat. Younger peat exhibits facies changes between sedge-rich components that filled troughs over the ice wedges and woody bryophytic deposits that formed beyond the troughs. A final episode of wedge development took place within the past few hundred years. Pollen data from the site indicate that boreal forest was present throughout the past 6000 yr, but that it underwent a gradual transition from a predominantly deciduous to a spruce-dominated assemblage. This change may reflect either local site conditions or a more general climatic shift to cooler, moister summers in late Holocene time. The history of ice-wedge growth shows that wedges can form and grow to more than 1 m apparent width under mean annual temperatures that probably are close to those of the Fairbanks area today (-3.5°C) and under vegetation cover similar to that of the interior Alaskan boreal forest. The commonly held belief that ice wedges develop only below mean annual air temperatures of -6 to -8°C in the zone of continuous permafrost is invalid.

  20. Portal dosimetry in wedged beams

    NARCIS (Netherlands)

    Spreeuw, Hanno; Rozendaal, Roel; Camargo, Priscilla; Mans, Anton; Wendling, Markus; Olaciregui-Ruiz, Igor; Sonke, Jan-Jakob; van Herk, Marcel; Mijnheer, Ben

    2015-01-01

    Portal dosimetry using electronic portal imaging devices (EPIDs) is often applied to verify high-energy photon beam treatments. Due to the change in photon energy spectrum, the resulting dose values are, however, not very accurate in the case of wedged beams if the pixel-to-dose conversion for the

  1. Application of super-omni wedge concept to conformal radiotherapy treatment planning

    International Nuclear Information System (INIS)

    Dai Jianrong; Fu Weihua; Hu Yimin

    2004-01-01

    Objective: To describe a method which can optimize beam weight, wedge angle, and wedge orientation simultaneously by combining the super-omni wedge (SOW) concept with the function of beam weight optimization provided by a commercial treatment planning system. Methods: A five-step procedure including: Step 1. To set up four 60 degree nominal wedged beams for each beam direction with the wedge orientations of 'LEFT', 'IN', 'RIGHT', 'OUT', respectively; Step 2. To define an optimization request, including an optimization goal and constraints. Authors use CMS Focus treatment planning system which allows us to choose 'maximize target dose' or 'minimize critical structure dose' as the optimization goal, and to set minimum target dose, maximum target dose, and maximum average dose of critical structures as constraints. Then the optimization process was launched as step 3; Step 4. To evaluate the plan using isodose distributions and dose-volume histograms. If acceptable, go to Step 5. Otherwise, go back to Step 2 to modify optimization constraints; and Step 5. Transform the SOW beams into the beams of omni wedge so as to reduce the number of to-be-delivered beams. Results: This procedure was found being able to demonstrate successfully in two clinical cases: an esophageal carcinoma and a brain tumor. Compared with manually designed plan, the optimized plan showed better dose homogeneity in the targets and better sparing of the critical structures. Conclusions: This method described is able to optimize beam weights while working with a treatment planning system. Not only does it improve treatment plans' quality, but also shorten the treatment planning process

  2. Variations in depth-dose data between open and wedge fields for 4-MV x-rays

    International Nuclear Information System (INIS)

    Sewchand, W.; Khan, F.M.; Williamson, J.

    1978-01-01

    Central-axis depth-dose data for 4-MV x rays, including tissue-maximum ratios, were measured for wedge fields. Comparison with corresponding open-field data revealed differences in magnitude which increased with depth, field size, and wedge thickness. However, phantom scatter correction factors for the wedge fields differed less than 1% from corresponding open-field factors. The differences in central-axis percent depth doses between the two types of fields indicate beam hardening by the wedge filter. This study also implies that the derivation of tissue-maximum ratios from central-axis percent depth is as valid for wedge as for open fields

  3. Decarbonization Wedges. November 2015. Report

    International Nuclear Information System (INIS)

    Alazard-Toux, N.; Criqui, P.; Devezeaux de Lavergne, J.G.; Chevallet, L.; Gentier, S.; Hache, E.; Le Net, E.; Menanteau, Ph.; Thais, Fr.; Achard, JL.; Allard, Fr.; Authier, O.; Babarit, A.; Badin, Fr.; Bazile, F.; Bernard, O.; Birat, JP.; Brault, P.; Burnol, A.; Carre, Fr.; Delrue, F.; Dufour, A.; Duplan, JL.; Durand, P.; Duval, O.; Fabriol, H.; Ferrant, P.; Flamant, G.; Forti, L.; Garnier, J.; Gimenez, M.; Goyeneche, O.; Hadj Said, N.; Jasserand, Fr.; Kalaydjian, F.; Le Boulluec, M.; Legrand, J.; Lorne, D.; Lucchese, P.; Magand, S.; Malbranche, Ph.; Mermillod, N.; Monot, F.; Olivier, B.; Pacaud, P.; Papillon, Ph.; Ponsot-Jacquin, C.; Quenard, D.; Rachez, X.; Rapin, M.; Rocher, Ph.; Sanjuan, B.; Sauvant-Moynot, V.; Tilagone, R.; Vinot, S.; Berthomieu, R.; Vajnovszki, A.

    2015-01-01

    2015 is a particularly eventful year in the field of energy. From 30 November through 11 December, France will host the 21. Conference of the Parties on Climate Change (COP21) in Paris. The expectations for this international event are high. Its main goal is to obtain an agreement to keep global warming below 2 deg. C by securing a set of voluntary commitments from the various countries and regions of the world to reduce global greenhouse gas emissions and by mobilizing $100 billion per year from 2020 onwards to finance climate change policies, especially in developing countries. In France, the year 2015 was also marked by the adoption of the Energy Transition and Green Growth Act that set a course and defined a road-map, through a set of objectives, aimed at helping our country reduce its CO 2 emissions in the field of energy. In this context, ANCRE (French National Alliance for Energy Research Coordination) would like to reiterate the major role of energy research and innovation in reducing anthropogenic (i.e. human induced) greenhouse gas emissions through research conducted on decarbonization wedges, a key technology in the fight against climate change in the field of energy on a planetary scale. Limiting the temperature increase on the earth's surface to 2 deg. C by 2100 is a challenging target, but it could be achievable with the rapid, sustained development and wide dissemination of a broad set of technologies. However, to achieve this goal, it is indispensable to conduct research aimed at speeding up low carbon technologies deployment and at reducing their cost. Through this joint report to which numerous researchers and experts contributed, ANCRE wishes to continue its efforts to build a global strategic vision that an Alliance comprising nearly 19 different research institutions can provide. This study follows the work conducted on energy transition scenarios for France and the road-maps drawn up by the ten programmatic groups structuring the

  4. Utilization of an electronic portal imaging device for measurement of dynamic wedge data

    International Nuclear Information System (INIS)

    Elder, Eric S.; Miner, Marc S.; Butker, Elizabeth K.; Sutton, Danny S.; Davis, Lawrence W.

    1996-01-01

    Purpose/Objective: Due to the motion of the collimator during dynamic wedge treatments, the conventional method of collecting comprehensive wedge data with a water tank and a scanning ionization chamber is obsolete. It is the objective of this work to demonstrate the use of an electronic portal imaging device (EPID) and software to accomplish this task. Materials and Methods: A Varian Clinac[reg] 2300 C/D, equipped with a PortalVision TM EPID and Dosimetry Research Mode experimental software, was used to produce the radiation field. The Dosimetry Research Mode experimental software allows for a band of 10 of 256 high voltage electrodes to be continuously read and averaged by the 256 electrometer electrodes. The file that is produced contains data relating to the integrated ionization at each of the 256 points, essentially the cross plane beam profile. Software was developed using Microsoft C ++ to reformat the data for import into a Microsoft Excel spreadsheet allowing for easy mathematical manipulation and graphical display. Beam profiles were measured by the EPID with a 100 cm TSD for various field sizes. Each field size was measured open, steel wedged, and dynamically wedged. Scanning ionization chamber measurements performed in a water tank were compared to the open and steel wedged fields. Ionization chamber measurements taken in a water tank were compared with the dynamically wedged measurements. For the EPID measurements the depth was varied using Gammex RMI Solid Water TM placed directly above the EPID sensitive volume. Bolus material was placed between the Solid Water TM and the EPID to avoid an air gap. Results: Comparison of EPID measurements with those from an ion chamber in a water tank showed a discrepancy of ∼5%. Scans were successfully obtained for open, steel wedged and dynamically wedged beams. Software has been developed to allow for easy graphical display of beam profiles. Conclusions: Measurement of dynamic wedge data proves to be easily

  5. Slamming pressures on the bottom of a free-falling vertical wedge

    Science.gov (United States)

    Ikeda, C. M.; Judge, C. Q.

    2013-11-01

    High-speed planing boats are subjected to repeat impacts due to slamming, which can cause structural damage and injury to passengers. A first step in understanding and predicting the physics of a craft re-entering the water after becoming partially airborne is an experimental vertical drop test of a prismastic wedge (deadrise angle, β =20° beam, B = 300 mm; and length, L = 600 mm). The acrylic wedge was mounted to a rig allowing it to free-fall into a deep-water tank (5.2m × 5.2m × 4.2m deep) from heights 0 camera (1000 fps, resolution of 1920 × 1200 pixels) is mounted above the wedge model to record the wetted surface as the wedge descended below the free surface. The pressure measurements taken with both conventional surface pressure transducers and the pressure mapping system agree within 10% of the peak pressure values (0.7 bar, typical). Supported by the Office of Naval Research.

  6. Wedge silicon detectors for the inner trackering system of CMS

    International Nuclear Information System (INIS)

    Catacchini, E.; Civinini, C.; D'Alessandro, R.; Focardi, E.; Meschini, M.; Parrini, G.; Pieri, M.; Wheadon, R.

    1997-01-01

    One ''wedge'' double sided silicon detector prototype for the CMS forward inner tracker has been tested both in laboratory and on a high energy particle beam. The results obtained indicate the most reliable solutions for the strip geometry of the junction side. Three different designs of ''wedge'' double sided detectors with different solutions for the ohmic side strip geometry are presented. (orig.)

  7. Peripheral Retinal Vascular Patterns in Patients with Rhegmatogenous Retinal Detachment in Taiwan

    Science.gov (United States)

    Chen, San-Ni; Hwang, Jiunn-Feng; Wu, Wen-Chuan

    2016-01-01

    This is an observational study of fluorescein angiography (FA) in consecutive patients with rhegmatogenous retinal detachment (RRD) in Changhua Christian Hospital to investigate the peripheral retinal vascular patterns in those patients. All patients had their age, sex, axial length (AXL), and refraction status (RF) recorded. According to the findings in FA of the peripheral retina, the eyes were divided into 4 groups: in group 1, there was a ramified pattern of peripheral retinal vasculature with gradual tapering; in group 2, there was an abrupt ending of peripheral vasculature with peripheral non-perfusion; in group 3, there was a curving route of peripheral vasculature forming vascular arcades or anastomosis; and in group 4, the same as in group 3, but with one or more wedge-shaped avascular notches. Comparisons of age, sex, AXL, and RF, association of breaks with lattice degeneration and retinal non-perfusion, surgical procedures utilized, and mean numbers of operations were made among the four groups. Of the 73 eyes studied, there were 13 eyes (17.8%) in group 1, 3 eyes (4.1%) in group 2, 40 eyes (54.8%) in group 3 and 17 eyes (23.3%) in group 4. Significant differences in age, AXL and RF, and association of retinal breaks to non-perfusion were noted among the four groups. Patients in group 1 had older ages, while younger ages were noted in groups 3 and 4. Eyes in group 1 had the shortest average AXL and were least myopic in contrast to the eyes in groups 3 and 4. Association of retinal breaks and retinal non-perfusion was significantly higher in groups 2, 3 and 4 than in group 1. In conclusion, peripheral vascular anomalies are common in cases with RRD. Patients with peripheral non-perfusion tend to be younger, with longer axial length and have the breaks associated with retinal non-perfusion. PMID:26909812

  8. Analysis of Fault Spacing in Thrust-Belt Wedges Using Numerical Modeling

    Science.gov (United States)

    Regensburger, P. V.; Ito, G.

    2017-12-01

    Numerical modeling is invaluable in studying the mechanical processes governing the evolution of geologic features such as thrust-belt wedges. The mechanisms controlling thrust fault spacing in wedges is not well understood. Our numerical model treats the thrust belt as a visco-elastic-plastic continuum and uses a finite-difference, marker-in-cell method to solve for conservation of mass and momentum. From these conservation laws, stress is calculated and Byerlee's law is used to determine the shear stress required for a fault to form. Each model consists of a layer of crust, initially 3-km-thick, carried on top of a basal décollement, which moves at a constant speed towards a rigid backstop. A series of models were run with varied material properties, focusing on the angle of basal friction at the décollement, the angle of friction within the crust, and the cohesion of the crust. We investigate how these properties affected the spacing between thrusts that have the most time-integrated history of slip and therefore have the greatest effect on the large-scale undulations in surface topography. The surface position of these faults, which extend through most of the crustal layer, are identifiable as local maxima in positive curvature of surface topography. Tracking the temporal evolution of faults, we find that thrust blocks are widest when they first form at the front of the wedge and then they tend to contract over time as more crustal material is carried to the wedge. Within each model, thrust blocks form with similar initial widths, but individual thrust blocks develop differently and may approach an asymptotic width over time. The median of thrust block widths across the whole wedge tends to decrease with time. Median fault spacing shows a positive correlation with both wedge cohesion and internal friction. In contrast, median fault spacing exhibits a negative correlation at small angles of basal friction (laws that can be used to predict fault spacing in

  9. North Aegean core complexes, the gravity spreading of a thrust wedge

    NARCIS (Netherlands)

    Kydonakis, Konstantinos; Brun, Jean Pierre; Sokoutis, Dimitrios

    2015-01-01

    The North Aegean core complexes developed in middle Eocene soon after the end of continental block convergence and piling up of the Hellenic Thrust Wedge. They formed during back-arc extension, driven by the Hellenic slab rollback, at the back of the thrust wedge. A series of scaled laboratory

  10. Magnetization study of interlayer exchange in semiconductor EuS-PbS ferromagnetic wedge multilayers

    International Nuclear Information System (INIS)

    Kowalczyk, L.; Osinniy, V.; Chernyshova, M.; Dziawa, P.; Boratynski, A.; Story, T.; Smits, C.J.P.; Swagten, H.J.M.; Sipatov, A.Yu.; Volobuev, V.V.

    2006-01-01

    Interlayer coupling was experimentally studied in semiconductor EuS-PbS ferromagnetic superlattice wedge structures grown on KCl (0 0 1) substrates with the wedges covering the semiconductor nonmagnetic PbS spacer layer thickness from 0.3 to 6 nm. Structural parameters of the wedges were examined by X-ray diffraction analysis of EuS-PbS superlattice period. Measurements of magnetic hysteresis loops of EuS-PbS structures were performed by both SQUID (for small terminal parts of the wedge) and MOKE (magneto-optical analysis along the wedge) magnetometry. A strong decrease of magnetic remanence and an increase of saturation field observed for EuS-PbS structures with the PbS spacer thickness decreasing below about 1.5 nm is discussed in terms of the influence of antiferromagnetic interlayer coupling

  11. Does IMRT increase the peripheral radiation dose? A comparison of treatment plans 2000 and 2010

    International Nuclear Information System (INIS)

    Salz, Henning; Eichner, Regina; Wiezorek, Tilo

    2012-01-01

    It has been reported in several papers and textbooks that IMRT treatments increase the peripheral dose in comparison with non-IMRT fields. But in clinical practice not only open fields have been used in the pre-IMRT era, but also fields with physical wedges or composed fields. The aim of this work is to test the hypothesis of increased peripheral dose when IMRT is used compared to standard conformal radiotherapy. Furthermore, the importance of the measured dose differences in clinical practice is discussed and compared with other new technologies for the cases where an increase of the peripheral dose was observed. For cancers of the head and neck, the cervix, the rectum and for the brain irradiation due to acute leukaemia, one to four plans have been calculated with IMRT or conformal standard technique (non-IMRT). In an anthropomorphic phantom the dose at a distance of 30 cm in cranio-caudal direction from the target edge was measured with TLDs using a linear accelerator Oncor registered (Siemens) for both techniques. IMRT was performed using step-and-shoot technique (7 to 11 beams), non-IMRT plans with different techniques. The results depended on the site of irradiation. For head and neck cancers IMRT resulted in an increase of 0.05 - 0.09% of the prescribed total dose (Dptv) or 40 - 70 mGy (Dptv = 65 Gy), compared to non-IMRT technique without wedges or a decrease of 0.16% (approx. 100 mGy) of the prescribed total dose compared to non-IMRT techniques with wedges. For the cervical cancer IMRT resulted in an increased dose in the periphery (+ 0.07% - 0.15% of Dptv or 30 - 70 mGy at Dptv = 45 Gy), for the rectal cancer in a dose reduction (0.21 - 0.26% of Dptv or 100 - 130 mGy at Dptv = 50 Gy) and for the brain irradiation in an increase dose (+ 0.05% of Dptv = 18 Gy or 9 mSv). In summary IMRT does not uniformly cause increased radiation dose in the periphery in the model used. It can be stated that these dose values are smaller than reported in earlier papers

  12. Scattering of wedges and cones with impedance boundary conditions

    CERN Document Server

    Lyalinov, Mikhail

    2012-01-01

    This book is a systematic and detailed exposition of different analytical techniques used in studying two of the canonical problems, the wave scattering by wedges or cones with impedance boundary conditions. It is the first reference on novel, highly efficient analytical-numerical approaches for wave diffraction by impedance wedges or cones. The applicability of the reported solution procedures and formulae to existing software packages designed for real-world high-frequency problems encountered in antenna, wave propagation, and radar cross section.

  13. New Transition Wedge Design Composed by Prefabricated Reinforced Concrete Slabs

    Directory of Open Access Journals (Sweden)

    Julia Real-Herráiz

    Full Text Available Abstract Important track degradation occurs in structure-embankment transitions, in which an abrupt change in track vertical stiffness arises, leading to a reduction in passengers comfort and safety. Although granular wedges are suggested by different railroad administrations as a solution to avoid these problems, they present some disadvantages which may affect track long-term performance. In this paper, a new solution designed with prefabricated reinforced concrete slabs is proposed. The aim of this solution is to guarantee a continuous and gradual track vertical stiffness transition in the vicinity of structures, overcoming granular wedges disadvantages. The aim of this study is to assess the performance of the novel wedge design by means of a 3-D FEM model and to compare it with the current solution.

  14. Seismic characterization of a `compound tectonic wedge` beneath the Rocky Mountain foreland basin, Alberta

    Energy Technology Data Exchange (ETDEWEB)

    Lawton, D. C.; Sukaramongkol, C.; Spratt, D. A. [Calgary Univ., AB (Canada). Dept. of Geology and Geophysics

    1996-06-01

    The detailed internal geometry of a `compound tectonic wedge` beneath an eastward-dipping homocline in the Sundre area of southern Alberta was described. Data for the description was obtained by interpreting reflection seismic data. The wedge has been driven into the foreland succession beneath the gently dipping upper detachment which occurs within coal horizons of the Upper Brazeau Group. Shape of the upper detachment near its toe indicates that rocks in its hanging wall were decoupled from strain associated with forward emplacement of the wedge. Folding of the upper detachment occurs in the hinterland region of the wedge, with a new upper detachment developing above the fold. Emplacement of the wedge is suspected to be the result of excess pore fluid pressure, although proof of this happening awaits quantification of the mechanical model. 25 refs., 8 figs.

  15. Tax wedge in Croatia, Belgium, Estonia, Germany and Slovakia

    Directory of Open Access Journals (Sweden)

    Ana Gabrilo

    2016-06-01

    Full Text Available The aim of this paper is to analyse the taxation of labour income in Croatia, Belgium,Estonia, Germany and Slovakia. Having presented an outline of tax system rules, the paper shows the decomposition of the net average tax wedge for different family types and different income levels based on the OECD methodology. The results show that all observed countries apply a progressive tax schedule, apart from Germany where taxation for higher gross wages is not progressive due to a  cap on the SIC base. When it comes to a taxpayer earning an average gross wage, a Croatian single worker without children has the lowest tax burden, followed by Estonia, Slovakia, Germany and Belgium. However, as regards taxpayers earning 400% of AGW, Estonia has the smallest tax wedge, followed by Slovakia, Germany, Croatia and Belgium. Similar results are obtained by analyzing the tax wedge for couples with two children where one spouse is out of work.

  16. Owhership of flats

    OpenAIRE

    Přibil, Jan

    2012-01-01

    Ownership of Flats Summary In his diploma thesis "Ownership of Flats", the author focuses on applicable law of flat ownership in the Czech Republic, especially the Flat Ownership Act 72/1994 Sb. The author puts the contemporary regulation in historical context; he describes the theoretical principles underlining the current applicable law and defines in detail the basic legal terms used by the Flat Ownership Act. Original and derivative forms of flat ownership acquisition are explained, namel...

  17. Therapy by stationary photon fields from a 42 MeV betatron using wedge filters

    International Nuclear Information System (INIS)

    Wicke, L.; Kaercher, K.H.; Naesiger, H.; Prokosch, E.; Vienna Univ.

    1975-01-01

    The dose distribution in photon beams from a 42 MeV betatron using wedge filters of lead with different angles of slope is described. The wedge coefficient to be considered at a field size of 10 x 10 cm is given. The scope for isodoses modified by wedge filters is discussed with regard to stationary-field photon therapy. (orig.) [de

  18. Wedge geometry, frictional properties and interseismic coupling of the Java megathrust

    Science.gov (United States)

    Koulali, Achraf; McClusky, Simon; Cummins, Phil; Tregoning, Paul

    2018-06-01

    The mechanical interaction between rocks at fault zones is a key element for understanding how earthquakes nucleate and propagate. Therefore, estimating frictional properties along fault planes allows us to infer the degree of elastic strain accumulation throughout the seismic cycle. The Java subduction zone is an active plate boundary where high seismic activity has long been documented. However, very little is known about the seismogenic processes of the megathrust, especially its shallowest portion where onshore geodetic networks are insensitive to recover the pattern of elastic strain. Here, we use the geometry of the offshore accretionary prism to infer frictional properties along the Java subduction zone, using Coulomb critical taper theory. We show that large portions of the inner wedge in the eastern part of the Java subduction megathrust are in a critical state, where the wedge is on the verge of failure everywhere. We identify four clusters with an internal coefficient of friction μint of ∼ 0.8 and hydrostatic pore pressure within the wedge. The average effective coefficient of friction ranges between 0.3 and 0.4, reflecting a strong décollement. Our results also show that the aftershock sequence of the 1994 Mw 7.9 earthquake halted adjacent to a critical segment of the wedge, suggesting that critical taper wedge areas in the eastern Java subduction interface may behave as a permanent barrier to large earthquake rupture. In contrast, in western Java topographic slope and slab dip profiles suggest that the wedge is mechanically stable, i.e deformation is restricted to sliding along the décollement, and likely to coincide with a seismogenic portion of the megathrust. We discuss the seismic hazard implications and highlight the importance of considering the segmentation of the Java subduction zone when assessing the seismic hazard of this region.

  19. Three Years of High Resolution Year-Round Monitoring of Ice-Wedge Thermal Contraction Cracking in Svalbard

    Science.gov (United States)

    Christiansen, H. H.

    2006-12-01

    Most likely ice-wedges are the most widespread periglacial landform in lowlands with continuous permafrost. With a changing climate it is important to understand better the geomorphological processes controlling ice- wedge growth and decay, as they might cause large changes to the surface of the landscape, particularly if the active layer thickness increases causing melting of the most ice-rich permafrost top layer. As most settlements on permafrost are located in lowland areas, ice-wedge formation can also influence the infrastructure. Understanding the processes of ice-wedge growth and their thaw transformation into ice-wedge casts are essential when using contemporary ice wedges as analogues of Pleistocene thermal contraction cracking in palaeoenvironmental reconstructions. As ice-wedges are largely controlled by winter conditions, improved understanding of the factors controlling their growth will enable better palaeoclimatic reconstructions both directly from ice-wedges, but also from ice-wedge casts, than just mean winter temperatures. Detailed studies of ice-wedge dynamics, including quantification of movement, have only been done in very few places in the Arctic. In high arctic Svalbard at 78°N climate at sea level locates these islands close to the southern limit of the continuous permafrost zone, with MAAT of as much as -4 to -6°C. However, thermal contraction cracking is demonstrated to be widespread in the Adventdalen study area in Svalbard. The year-round field access from the University Centre in Svalbard, UNIS, has enabled the collection of different continuous or high frequency ice-wedge process monitoring data since 2002 to improve the understanding of the geomorphological activity of this landform. In all the winters the air temperature was below -30°C for shorter or longer periods. During all the winters, the temperature in the top permafrost was below -15°C both in the ice-wedge top for shorter or longer periods. The snow cover was

  20. Assessment of an amorphous silicon EPID for quality assurance of enhanced dynamic wedge

    International Nuclear Information System (INIS)

    Greer, P.

    2004-01-01

    Full text: Routine quality assurance (QA) of enhanced dynamic wedge (EDW) is usually performed weekly to monthly. Wedge factors are measured with ion-chamber, and profiles usually with diode-arrays such as the Profiler. The use of an electronic portal imaging device (EPID) for these measurements would combine these into a single rapid set-up and measurement. Currently the Varian EPID in standard imaging mode will not acquire integrated images during EDW treatments, and therefore has not been utilised for EDW dosimetry. Modification to image acquisition was made to enable imaging for EDW, and the performance of the EPID for suitability for quality assurance of EDW was investigated. The accuracy of EDW profiles measured with the EPID were assessed by comparison to Profiler measurements. The EPID was positioned at 105 cm to the detector surface, with 4 cm of additional solid water build-up to give total build-up including EPID inherent build-up of 5 cm. Images of EDW fields were acquired with continuous frame-averaging throughout the delivery. Field sizes of 10x10 cm, and 20x20 cm were used for 30 deg and 60 deg wedge angles for both 6 MV and 18 MV x-rays. Profiler measurements of the same fields were made with 5 cm of solid water build-up with 105 cm to the detector. Profiles in the wedged direction along the central axis of the beam were then compared. The reproducibility of the EPID measured profiles was assessed by three measurements made at weekly intervals. The accuracy of EPID measured wedge factors was investigated with the same experimental set-up. Three images of a 10x10 cm open field were acquired, and the mean pixel value in a 9x9 pixel region at the central axis was found. As the pixel value is the average of all acquired frames, this was multiplied by the number of frames to yield an integrated pixel value. This was repeated for three 10x10 cm 60 deg wedge irradiations. The wedge factor measured with the EPID was then compared to routine weekly

  1. Measured Hydrologic Storage Characteristics of Three Major Ice Wedge Polygon Types, Barrow, Alaska

    Science.gov (United States)

    Chamberlain, A. J.; Liljedahl, A.; Wilson, C. J.; Cable, W.; Romanovsky, V. E.

    2014-12-01

    Model simulations have suggested that the hydrologic fluxes and stores of Arctic wetlands are constrained by the micro-topographical features of ice wedge polygons, which are abundant in lowland tundra landscapes. Recently observed changes in ice wedge polygon landscapes - in particular, ice wedge degradation and trough formation - emphasize the need to better understand how differing ice wedge polygon morphologies affect the larger hydrologic system. Here we present three seasons of measured end-of-winter snow accumulation, continuous soil moisture and water table elevations, and repeated frost table mapping. Together, these describe the hydrologic characteristics of three main ice wedge polygon types: low centered polygons with limited trough development (representative of a ~500 year old vegetated drained thaw lake basin), and low- and high-centered polygons with well-defined troughs. Dramatic spatiotemporal variability exists both between polygon types and between the features of an individual polygon (e.g. troughs, centers, rims). Landscape-scale end-of-winter snow water equivalent is similar between polygon types, while the sub-polygon scale distribution of the surface water differs, both as snow and as ponded water. Some sub-polygon features appear buffered against large variations in water levels, while others display periods of prolonged recessions and large responses to rain events. Frost table elevations in general mimic the ground surface topography, but with spatiotemporal variability in thaw rate. The studied thaw seasons represented above long-term average rainfall, and in 2014, record high June precipitation. Differing ice wedge polygon types express dramatically different local hydrology, despite nearly identical climate forcing and landscape-scale snow accumulation, making ice wedge polygons an important component when describing the Arctic water, nutrient and energy system.

  2. Laser-based linear and nonlinear guided elastic waves at surfaces (2D) and wedges (1D).

    Science.gov (United States)

    Hess, Peter; Lomonosov, Alexey M; Mayer, Andreas P

    2014-01-01

    The characteristic features and applications of linear and nonlinear guided elastic waves propagating along surfaces (2D) and wedges (1D) are discussed. Laser-based excitation, detection, or contact-free analysis of these guided waves with pump-probe methods are reviewed. Determination of material parameters by broadband surface acoustic waves (SAWs) and other applications in nondestructive evaluation (NDE) are considered. The realization of nonlinear SAWs in the form of solitary waves and as shock waves, used for the determination of the fracture strength, is described. The unique properties of dispersion-free wedge waves (WWs) propagating along homogeneous wedges and of dispersive wedge waves observed in the presence of wedge modifications such as tip truncation or coatings are outlined. Theoretical and experimental results on nonlinear wedge waves in isotropic and anisotropic solids are presented. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Calibration of the Wedge Prism

    Science.gov (United States)

    Charles B. Briscoe

    1957-01-01

    Since the introduction of plotless cruising in this country by Grosenbaugh and the later suggestion of using a wedge prism as an angle gauge by Bruce this method of determining basal area has been widely adopted in the South. One of the factors contributing to the occasionally unsatisfactory results obtained is failure to calibrate the prism used. As noted by Bruce the...

  4. The Comparison of Forces Applied to the Knee Extensor Mechanism during Stance Phase of Gait in Flat Footed Females Three Different in-Shoe Orthotics

    Directory of Open Access Journals (Sweden)

    Mohsen Razeghi

    2012-01-01

    Full Text Available Objective: It has been postulated that subtalar position and movement would influence the function of the foot and the lower limb’s biomechanical alignment as a whole. The aim of this study was to compare the changes of force applied to the knee extensor mechanism of the female subjects while applying three different in-shoe orthotic appliances. Materials & Methods: Feiss Line test was used to assign a group of 10 healthy female subjects aged at 19-25 years as flat foot group. Retro reflective calibration and tracking markers were placed on the subjects over anatomically relevant locations. Kinematic and kinetic data were collected by employing a three dimensional motion capture system (Qualisys®Ltd, Sweden and a force platform (Kistler®, Switzerland respectively, while subjects walked at their preferred speed with 3 different in-shoe orthotics: simple insole, insole with medial arch support, insole with medial arch support and medial heel wedge, and insole with medial arch support and lateral forefoot wedge. Results: A statistically significant lower amount of the force applied to the extensor mechanism was found while applying medial arch support combined with lateral wedge (P=0.005. Conclusion: It could be concluded that changes of the different foot insoles would alter the force applied to the knee extensor mechanism. Results of this study emphasize the immediate effect of applying a medial arch support combined lateral wedge on reduction of the force applied to the extensor mechanism through which decrease a tendency towards musculoskeletal injuries.

  5. A Novel Continuous Extrusion Process to Fabricate Wedge-Shaped Light Guide Plates

    Directory of Open Access Journals (Sweden)

    Wen-Tse Hsiao

    2013-01-01

    Full Text Available Backlight modules are key components in thin-film transistor liquid crystal displays (TFT-LCD. Among the components of a backlight module, the light guide plate (LGP plays the most important role controlling the light projected to the eyes of users. A wedge-shaped LGP, with its asymmetrical structure, is usually fabricated by an injection proces, but the fabrication time of this process is long. This study proposes a continuous extrusion process to fabricate wedge-shaped LGPs. This continuous process has advantages for mass production. Besides a T-die and rollers, this system also has an in situ monitor of the melt-bank that forms during the extrusion process, helping control the plate thickness. Results show that the melt bank has a close relationship with the plate thickness. The temperature of the bottom heater and roller was adjusted to reduce the surface deformation of the wedge-shaped plate. This continuous extrusion system can successfully manufacture wedge-shaped LGPs for mass production.

  6. Observations of Lower Mississippi River Estuarine Dynamics: Effects of the Salt Wedge on Sediment Deposition

    Science.gov (United States)

    Ramirez, M. T.; Allison, M. A.

    2017-12-01

    The lowermost Mississippi River is subject to salt-wedge estuarine conditions during seasonally low flow, when seaward flow is unable to overcome density stratification. Previous studies in the Mississippi River salt wedge have shown the deposition of a fine sediment layer accumulating several mm/day beneath the reach where the salt wedge is present. Field studies were conducted during low flow in 2012-2015 utilizing ADCP, CTD, LISST, and physical samples to observe the physics of the salt wedge reach and to calculate rates and character of sediment trapping beneath the salt wedge. The field observations were summarized using a two-layer box-model representation of the reach to calculate water and sediment budgets entering, exiting, and stored within the reach. The salt wedge reach was found to be net depositional at rates up to 1.8 mm/day. The mechanism for transferring sediment mass from the downstream-flowing fluvial layer to the upstream-flowing marine layer appears to be flocculation, evidenced in LISST data by a spike in sediment particle diameters at the halocline. Applying reach-averaged rates of sediment trapping to a time-integrated model of salt-wedge position, we calculated annual totals ranging from 0.025 to 2.2 million tons of sediment deposited beneath the salt wedge, depending on salt-wedge persistence and upstream extent. Most years this seasonal deposit is remobilized during spring flood following the low-flow estuarine season, which may affect the timing of sediment delivery to the Gulf of Mexico, as well as particulate organic carbon, whose transport trajectory mirrors that of mineral sediment. These results are also relevant to ongoing dredging efforts necessary to maintain the economically-important navigation pathway through the lower Mississippi River, as well as planned efforts to use Mississippi River sedimentary resources to build land in the degrading Louisiana deltaic coast.

  7. The synthesis and adsorption properties of some carbohydrate-terminated dendrimer wedges

    International Nuclear Information System (INIS)

    Ainsworth, Richard L.

    1997-01-01

    A range of dendritic molecules that are designed to bind to a cotton surface has been synthesised. The architecture of the molecules allows the location of various functional, property modifying units at the focus and the attachment of recognition groups at the periphery of a dendritic molecule with wedge topology. The synthesis and characterisation of dendrimer wedges up to the second generation using a divergent approach has been performed. These wedges are readily built up using a simple and efficient stepwise pathway from the central core, and surface recognising species are subsequently attached to the molecule utilising procedures developed in conjunction with Unilever Research Laboratories. Work has been carried out to assess their adsorption onto a cotton surface and the postulated adsorption mechanism is discussed. (author)

  8. Surgical quality of wedge resection affects overall survival in patients with early stage non-small cell lung cancer.

    Science.gov (United States)

    Ajmani, Gaurav S; Wang, Chi-Hsiung; Kim, Ki Wan; Howington, John A; Krantz, Seth B

    2018-07-01

    Very few studies have examined the quality of wedge resection in patients with non-small cell lung cancer. Using the National Cancer Database, we evaluated whether the quality of wedge resection affects overall survival in patients with early disease and how these outcomes compare with those of patients who receive stereotactic radiation. We identified 14,328 patients with cT1 to T2, N0, M0 disease treated with wedge resection (n = 10,032) or stereotactic radiation (n = 4296) from 2005 to 2013 and developed a subsample of propensity-matched wedge and radiation patients. Wedge quality was grouped as high (negative margins, >5 nodes), average (negative margins, ≤5 nodes), and poor (positive margins). Overall survival was compared between patients who received wedge resection of different quality and those who received radiation, adjusting for demographic and clinical variables. Among patients who underwent wedge resection, 94.6% had negative margins, 44.3% had 0 nodes examined, 17.1% had >5 examined, and 3.0% were nodally upstaged; 16.7% received a high-quality wedge, which was associated with a lower risk of death compared with average-quality resection (adjusted hazard ratio [aHR], 0.74; 95% confidence interval [CI], 0.67-0.82). Compared with stereotactic radiation, wedge patients with negative margins had significantly reduced hazard of death (>5 nodes: aHR, 0.50; 95% CI, 0.43-0.58; ≤5 nodes: aHR, 0.65; 95% CI, 0.60-0.70). There was no significant survival difference between margin-positive wedge and radiation. Lymph nodes examined and margins obtained are important quality metrics in wedge resection. A high-quality wedge appears to confer a significant survival advantage over lower-quality wedge and stereotactic radiation. A margin-positive wedge appears to offer no benefit compared with radiation. Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  9. The optimisation of wedge filters in radiotherapy of the prostate

    International Nuclear Information System (INIS)

    Oldham, Mark; Neal, Anthony J.; Webb, Steve

    1995-01-01

    A treatment plan optimisation algorithm has been applied to 12 patients with early prostate cancer in order to determine the optimum beam-weights and wedge angles for a standard conformal three-field treatment technique. The optimisation algorithm was based on fast-simulated-annealing using a cost function designed to achieve a uniform dose in the planning-target-volume (PTV) and to minimise the integral doses to the organs-at-risk. The algorithm has been applied to standard conformal three-field plans created by an experienced human planner, and run in three PLAN MODES: (1) where the wedge angles were fixed by the human planner and only the beam-weights were optimised; (2) where both the wedge angles and beam-weights were optimised; and (3) where both the wedge angles and beam-weights were optimised and a non-uniform dose was prescribed to the PTV. In the latter PLAN MODE, a uniform 100% dose was prescribed to all of the PTV except for that region that overlaps with the rectum where a lower (e.g., 90%) dose was prescribed. The resulting optimised plans have been compared with those of the human planner who found beam-weights by conventional forward planning techniques. Plans were compared on the basis of dose statistics, normal-tissue-complication-probability (NTCP) and tumour-control-probability (TCP). The results of the comparison showed that all three PLAN MODES produced plans with slightly higher TCP for the same rectal NTCP, than the human planner. The best results were observed for PLAN MODE 3, where an average increase in TCP of 0.73% (± 0.20, 95% confidence interval) was predicted by the biological models. This increase arises from a beneficial dose gradient which is produced across the tumour. Although the TCP gain is small it comes with no increase in treatment complexity, and could translate into increased cures given the large numbers of patients being referred. A study of the beam-weights and wedge angles chosen by the optimisation algorithm revealed

  10. Chronology and palaeoenvironmental implications of the ice-wedge pseudomorphs and composite-wedge casts on the Magdalen Islands (eastern Canada)

    DEFF Research Database (Denmark)

    Remillard, A.M.; Hetu, B.; Bernatchez, P.

    2015-01-01

    to the former presence of permafrost under periglacial conditions. These features truncate Carboniferous sandstone or Last Glacial Maximum (LGM) glacial and glaciomarine diamicts, both overlain by subtidal or coastal units. Six optically stimulated luminescence (OSL) and four radiocarbon ages were obtained from......The Magdalen Islands are a valuable terrestrial record, evidencing the complex glacial and periglacial history of the Gulf of St. Lawrence. Thirteen structures interpreted as ice-wedge pseudomorphs or composite-wedge casts were observed at four sites on the southern Magdalen Islands and testify...... both host and infilled sedimentary units. These ages provide the first absolute chronological data on these structures, shedding new light on the relationships between glacial and periglacial phases. Our chronostratigraphic data suggest that, after the deglaciation and the emersion of the archipelago...

  11. Rainfall induced groundwater mound in wedge-shaped promontories: The Strack-Chernyshov model revisited

    Science.gov (United States)

    Kacimov, A. R.; Kayumov, I. R.; Al-Maktoumi, A.

    2016-11-01

    An analytical solution to the Poisson equation governing Strack's discharge potential (squared thickness of a saturated zone in an unconfined aquifer) is obtained in a wedge-shaped domain with given head boundary conditions on the wedge sides (specified water level in an open water body around a porous promontory). The discharge vector components, maximum elevation of the water table in promontory vertical cross-sections, quantity of groundwater seeping through segments of the wedge sides, the volume of fresh groundwater in the mound are found. For acute angles, the solution to the problem is non-unique and specification of the behaviour at infinity is needed. A ;basic; solution is distinguished, which minimizes the water table height above a horizontal bedrock. MODFLOW simulations are carried out in a finite triangular island and compare solutions with a constant-head, no-flow and ;basic; boundary condition on one side of the triangle. Far from the tip of an infinite-size promontory one has to be cautious with truncation of the simulated flow domains and imposing corresponding boundary conditions. For a right and obtuse wedge angles, there are no positive solutions for the case of constant accretion on the water table. In a particular case of a confined rigid wedge-shaped aquifer and incompressible fluid, from an explicit solution to the Laplace equation for the hydraulic head with arbitrary time-space varying boundary conditions along the promontory rays, essentially 2-D transient Darcian flows within the wedge are computed. They illustrate that surface water waves on the promontory boundaries can generate strong Darcian waves inside the porous wedge. Evaporation from the water table and sea-water intruded interface (rather than a horizontal bed) are straightforward generalizations for the Poissonian Strack potential.

  12. Physical optics-based diffraction coefficient for a wedge with different face impedances.

    Science.gov (United States)

    Umul, Yusuf Ziya

    2018-03-20

    A new diffraction field expression is introduced with the aid of the modified theory of physical optics for a wedge with different face impedances. First, the scattered geometrical optics fields are determined when both faces of the wedge are illuminated by the incident wave. The geometrical optics waves are then expressed in terms of the sum of two different fields that occur for different impedance wedges. The diffracted fields are determined for the two cases separately, and the total diffracted field is obtained as a sum of these waves. Lastly, the uniform field expressions are obtained, and the resultant fields are numerically compared with the solution of Maliuzhinets.

  13. Evaluation of flat panel PMT for gamma ray imaging

    International Nuclear Information System (INIS)

    Pani, R.; Cinti, M.N.; Pellegrini, R.; Trotta, C.; Trotta, G.; Montani, L.; Ridolfi, S.; Garibaldi, F.; Scafe, R.; Belcari, N.; Del Guerra, A.

    2003-01-01

    The first position sensitive PMT, Hamamatsu R2486, developed in 1985, represented a strong technological advance for gamma-ray imaging. Hamamatsu H8500 Flat Panel PMT is the last generation position sensitive PMT: extremely compact with 2 in. active area. Its main features are: minimum peripheral dead zone (1 mm) and height of 12 mm. It was designed to be assembled in array to cover large detection area. It can represent a technical revolution for many applications in the field of gamma-ray imaging as for example nuclear medicine. This tube is based on metal channel dynode for charge multiplication and 8x8 anodes for charge collection and position calculation. In this paper we present a preliminary evaluation of the imaging performances addressed to nuclear medicine application. To this aim we have taken into account two different electronic readouts: resistive chain with Anger Camera principle and multianode readout. Flat panel PMT was coupled to CsI(Tl) and NaI(Tl) scintillation arrays. The results were also compared with the first generation PSPMT

  14. Improved field abutment-wedge design for 6-MV x-rays

    International Nuclear Information System (INIS)

    Nyerick, C.E.; Steadham, R.E.

    1989-01-01

    This paper presents an improved abutment wedge for matching large photon fields. The wedge is used with a 6-MV Linac accelerator and generates a 5-cm pseudopenumbra at the 50% relative dose juncture. The features allow treatment of fields up to 40 cm long in any fractional step of increment, simultaneous generation of two wide penumbrae or one wide and one sharp penumbra, and attachment of the device downstream of standard beam-shaping accessories in any 90 degrees angular orientation

  15. Tool life of ceramic wedges during precise turning of tungsten

    Directory of Open Access Journals (Sweden)

    Legutko Stanislaw

    2017-01-01

    Full Text Available Properties, application and machinability of tungsten and its alloys have been demonstrated. The comparison of the tool life and wear of the wedges made of SiAlON and whisker ceramics during the precise turning at different cutting parameters have been presented. The CNC lathe DMG CTX 310 Ecoline and tungsten of 99.7 % purity were used during the experiments. Only the wedge of whisker ceramics has proved to be sufficiently suitable and only for relatively low cutting speeds.

  16. Monte Carlo simulation of the Varian Clinac 600C accelerator using dynamic wedges

    International Nuclear Information System (INIS)

    Moreno, S.; Chaves, A.; Lopes, M.C.; Peralta, L.; Universidade de Lisboa

    2004-01-01

    The advent of linear accelerators (linac) with computer-controlled dynamic collimation systems and functional and anatomical imaging techniques allowed a more exact delimitation and localisation of the target volume. These advanced treatment techniques inevitably increase the complexity level of dose calculation because of the introduction of the temporal variable. On account of this, it is mandatory the usage of more accurate modelling techniques of the collimator components, as it is the case of Monte Carlo (MC) simulation, which has created an enormous interest in research and clinical practice. Because the patients bodies are not homogenous nor are their body surfaces plane and regular, the dose distribution may differ significantly from the standard distribution from the linac calibration. It is in the treatment planning systems, which include algorithms that are usually measured in homogeneous water phantoms specific for each correction that the dose distributions from each case are obtained. In a real treatment, exception made to superficial lesions, two or more radiation fields are used in order to obtain the recommended dose distributions. The simplest arrangement is made from two parallel and opposed fields that originate a homogeneous dose distribution in almost all the irradiated volume. The available resources are, for example, different types of energies and of radiation, the application of bolus, the protection of healthy structures, the usage of wedged filters and the application of dynamic wedges. A virtual or dynamic wedge, modelled through the movement of one of the jaws, when compared with a set of physical wedges offers an alternative calculation method of an arbitrary number of wedged fields, instead of the four traditional fields of 15 deg, 30 deg, 45 deg and 60 deg angle and obtained with physical wedges. The goal of this work consists in the study of the application of dynamic wedges in tailoring the radiation field by the Varian Clinac 600

  17. The application of wedge type compensation filter for uniform density on the endoscopic retrograde pancreatography

    International Nuclear Information System (INIS)

    Son, Soon Yong; Lee, Hee Jeong; Lee, Won Hong; Cho, Cheong Chan; Ryu, Meung Sun; Jung, Hong Ryang

    2001-01-01

    Over-density of pancreatic duct tail part on the endoscopic retrograde pancreatogram results from patient's position and inserted air during the study. The aim of this paper is to decide the filter angle to obtain an uniform density. Endoscopic retrograde pancratography was performed to 234 patients, and angled wedge filter was used differently. They are 10 deg (47), 20 deg (45), 30 deg (50). We also did not use wedge filter to 42 patients. We decided reliance degree in 95%. The statistical difference was p<0.05. The patients' sex rate was 1.8:1 between 18 and 87 years old(average age 58 years). Their body girth was 18.71 cm on the average. Of total 234 patients, difference of right and left average density was 0.01 by 30 deg wedge filter, -0.08 40 deg wedge filter and 0.27 non-wedge filter. These average values of difference density were very significant statistically, and standard deviation also was close to regular distribution. In conclusion, there is a usefulness of angled wedge filter for increasing diagnostic value of pancreatic duct tail part on the endoscopic retrograde pancreatogram

  18. Peripheral Retinal Vascular Patterns in Patients with Rhegmatogenous Retinal Detachment in Taiwan.

    Directory of Open Access Journals (Sweden)

    San-Ni Chen

    Full Text Available This is an observational study of fluorescein angiography (FA in consecutive patients with rhegmatogenous retinal detachment (RRD in Changhua Christian Hospital to investigate the peripheral retinal vascular patterns in those patients. All patients had their age, sex, axial length (AXL, and refraction status (RF recorded. According to the findings in FA of the peripheral retina, the eyes were divided into 4 groups: in group 1, there was a ramified pattern of peripheral retinal vasculature with gradual tapering; in group 2, there was an abrupt ending of peripheral vasculature with peripheral non-perfusion; in group 3, there was a curving route of peripheral vasculature forming vascular arcades or anastomosis; and in group 4, the same as in group 3, but with one or more wedge-shaped avascular notches. Comparisons of age, sex, AXL, and RF, association of breaks with lattice degeneration and retinal non-perfusion, surgical procedures utilized, and mean numbers of operations were made among the four groups. Of the 73 eyes studied, there were 13 eyes (17.8% in group 1, 3 eyes (4.1% in group 2, 40 eyes (54.8% in group 3 and 17 eyes (23.3% in group 4. Significant differences in age, AXL and RF, and association of retinal breaks to non-perfusion were noted among the four groups. Patients in group 1 had older ages, while younger ages were noted in groups 3 and 4. Eyes in group 1 had the shortest average AXL and were least myopic in contrast to the eyes in groups 3 and 4. Association of retinal breaks and retinal non-perfusion was significantly higher in groups 2, 3 and 4 than in group 1. In conclusion, peripheral vascular anomalies are common in cases with RRD. Patients with peripheral non-perfusion tend to be younger, with longer axial length and have the breaks associated with retinal non-perfusion.

  19. Cyclicity, episodicity, and continuity in accretionary wedge evolution: insights from geophysical imaging and physical analogue experiments

    Science.gov (United States)

    Kukowski, N.

    2009-04-01

    Geophysical profiles across active convergent margins reveal different styles and locations of sediment accretion, thrust slices dipping successively steeper towards the hinterland, splay faults, and blind thrusts as well as accumulation spaces e. g. thrust top basins and larger basins formed by regional subsidence, of very variable size and position. Morphologically, the continental slope at most margins can be sub-divided in a lower, middle, and upper slope, with often the middle slope being the most shallowly inclined, suggesting segmented wedges. Beneath the forearc, a subduction channel of a few hundred meters to a few km thickness marks a layer of material transport into greater depth that also hosts the plate interface and décollement zone. The petrographical composition of accretionary wedges and subduction channels as well as related pressures and temperatures are accessible through deep drilling or sampling fossil accretionary complexes now exhumed. The structure, lithology, and tectonic history of forearcs as identified from geophysical and geology field observations hint to parameters possibly controlling material transfer at convergent margins. Among them, sediment supply, which itself is largely controlled by climate, width of the subduction channel, and interplate frictional properties, which also exhibit control on plate coupling and therefore the seismic potential of a forearc, are suggested to be of major importance. These parameters further may undergo temporal fluctuation, e.g. when climate changes or when different material is entering the trench and therefore potentially also the subduction channel. High resolution monitoring of material flux and the evolution of fault zone kinematics of analogue experimental wedges made of granular materials exhibiting frictional behaviour equivalent to that of upper crustal rocks shows that accretionary cycles proceed as a chain of sub-processes, i.e. the development of a thrust slice from initial failure

  20. Development of Cone Wedge Ring Expansion Test to Evaluate Mechanical Properties of Clad Tubing Structure

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jy-An John [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-10-01

    To determine the hoop tensile properties of irradiated fuel cladding in a hot cell, a cone wedge ring expansion test method was developed. A four-piece wedge insert was designed with tapered angles matched to the cone shape of a loading piston. The ring specimen was expanded in the radial direction by the lateral expansion of the wedges under the downward movement of the piston. The advantages of the proposed method are that implementation of the test setup in a hot cell is simple and easy, and that it enables a direct strain measurement of the test specimen from the piston’s vertical displacement soon after the wedge-clad contact resistance is initiated.

  1. Peripheral doses from pediatric IMRT

    International Nuclear Information System (INIS)

    Klein, Eric E.; Maserang, Beth; Wood, Roy; Mansur, David

    2006-01-01

    Peripheral dose (PD) data exist for conventional fields (≥10 cm) and intensity-modulated radiotherapy (IMRT) delivery to standard adult-sized phantoms. Pediatric peripheral dose reports are limited to conventional therapy and are model based. Our goal was to ascertain whether data acquired from full phantom studies and/or pediatric models, with IMRT treatment times, could predict Organ at Risk (OAR) dose for pediatric IMRT. As monitor units (MUs) are greater for IMRT, it is expected IMRT PD will be higher; potentially compounded by decreased patient size (absorption). Baseline slab phantom peripheral dose measurements were conducted for very small field sizes (from 2 to 10 cm). Data were collected at distances ranging from 5 to 72 cm away from the field edges. Collimation was either with the collimating jaws or the multileaf collimator (MLC) oriented either perpendicular or along the peripheral dose measurement plane. For the clinical tests, five patients with intracranial or base of skull lesions were chosen. IMRT and conventional three-dimensional (3D) plans for the same patient/target/dose (180 cGy), were optimized without limitation to the number of fields or wedge use. Six MV, 120-leaf MLC Varian axial beams were used. A phantom mimicking a 3-year-old was configured per Center for Disease Control data. Micro (0.125 cc) and cylindrical (0.6 cc) ionization chambers were appropriated for the thyroid, breast, ovaries, and testes. The PD was recorded by electrometers set to the 10 -10 scale. Each system set was uniquely calibrated. For the slab phantom studies, close peripheral points were found to have a higher dose for low energy and larger field size and when MLC was not deployed. For points more distant from the field edge, the PD was higher for high-energy beams. MLC orientation was found to be inconsequential for the small fields tested. The thyroid dose was lower for IMRT delivery than that predicted for conventional (ratio of IMRT/cnventional ranged from

  2. Intercomparison of wedge factor for symmetric field and asymmetric field used 6MV linac

    International Nuclear Information System (INIS)

    Ji, Youn Sang; Han, Jae Jin

    1999-01-01

    Therapy equipment have taken progress for Cancer make use of Radiation for the normal tissue system make much of important for shielding. In modern times independent jaw setting to used equipment as possible make use of asymmetric field. Therefore, the asymmetric field be leave out of consideration wedge factor because of with used wedge for the most of part. These experimentation find out have an effect on the dosimetry of out put compared with of the difference between the symmetric field and asymmetric field for the wedge factor

  3. Impingement of water droplets on wedges and diamond airfoils at supersonic speeds

    Science.gov (United States)

    Serafini, John S

    1953-01-01

    An analytical solution has been obtained for the equations of motion of water droplets impinging on a wedge in a two-dimensional supersonic flow field with a shock wave attached to the wedge. The closed-form solution yields analytical expressions for the equation of the droplet trajectory, the local rate of impingement and the impingement velocity at any point on the wedge surface, and the total rate of impingement. The analytical expressions are utilized to determine the impingement on the forward surfaces of diamond airfoils in supersonic flow fields with attached shock waves. The results presented include the following conditions: droplet diameters from 2 to 100 microns, pressure altitudes from sea level to 30,000 feet, free-stream static temperatures from 420 degrees to 460 degrees R. Also, free-stream Mach numbers from 1.1 to 2.0, semi-apex angles for the wedge from 1.14 degrees to 7.97 degrees, thickness-to-chord ratios for the diamond airfoil from 0.02 to 0.14, chord lengths from 1 to 20 feet, and angles of attack from zero to the inverse tangent of the airfoil thickness-to-chord ratio.

  4. The influence of wedge diffuser blade number and divergence angle on the performance of a high pressure ratio centrifugal compressor

    Science.gov (United States)

    Wang, Yi; Han, Ge; Lu, Xingen; Zhu, Junqiang

    2018-02-01

    Wedge diffuser is widely used in centrifugal compressors due to its high performance and compact size. This paper is aimed to research the influence of wedge diffuser blade number and divergence angle on centrifugal compressor performance. The impact of wedge diffuser blade number on compressor stage performance is investigated, and then the wedge diffusers with different divergence angle are studied by varying diffuser wedge angle and blade number simultaneously. It is found that wedge diffuser with 27 blades could have about 0.8% higher adiabatic efficiency and 0.14 higher total pressure ratio than the wedge diffuser with 19 blades and the best compressor performance is achieved when diffuser divergence angle is 8.3°.These results could give some advices on centrifugal compressor design.

  5. Dispersion analysis and measurement of circular cylindrical wedge-like acoustic waveguides.

    Science.gov (United States)

    Yu, Tai-Ho

    2015-09-01

    This study investigated the propagation of flexural waves along the outer edge of a circular cylindrical wedge, the phase velocities, and the corresponding mode displacements. Thus far, only approximate solutions have been derived because the corresponding boundary-value problems are complex. In this study, dispersion curves were determined using the bi-dimensional finite element method and derived through the separation of variables and the Hamilton principle. Modal displacement calculations clarified that the maximal deformations appeared at the outer edge of the wedge tip. Numerical examples indicated how distinct thin-film materials deposited on the outer surface of the circular cylindrical wedge influenced the dispersion curves. Additionally, dispersion curves were measured using a laser-induced guided wave, a knife-edge measurement scheme, and a two-dimensional fast Fourier transform method. Both the numerical and experimental results correlated closely, thus validating the numerical solution. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Evaluation of off-axis wedge correction factor using diode dosimeters for estimation of delivered dose in external radiotherapy

    International Nuclear Information System (INIS)

    Allahverdi, Mahmoud; Shirazi, Alireza; Geraily, Ghazale; Mohammadkarim, Alireza; Esfehani, Mahbod; Nedaie, Hasanali

    2012-01-01

    An in vivo dosimetry system, using p-type diode dosimeters, was characterized for clinical applications of treatment machines ranging in megavoltage energies. This paper investigates two different models of diodes for externally wedged beams and explains a new algorithm for the calculation of the target dose at various tissue depths in external radiotherapy. The values of off-axis wedge correction factors were determined at two different positions in the wedged (toward the thick and thin edges) and in the non-wedged directions on entrance and exit surfaces of a polystyrene phantom in 60 Co and 6 MV photon beams. Depth transmission was defined on the entrance and exit surfaces to obtain the off-axis wedge correction factor at any depth. As the sensitivity of the diodes depends on physical characteristics (field size, source-skin distance (SSD), thickness, backscatter), correction factors were applied to the diode reading when measuring conditions different from calibration situations. The results indicate that needful correction factors for 60 Co wedged photons are usually larger than those for 6 MV wedged photon beams. In vivo dosimetry performed with the proposed algorithms at externally wedged beams has negligible probable errors (less than 0.5%) and is a reliable method for patient dose control. (author)

  7. Evaluation of off-axis wedge correction factor using diode dosimeters for estimation of delivered dose in external radiotherapy

    Directory of Open Access Journals (Sweden)

    Mahmoud Allahverdi

    2012-01-01

    Full Text Available An in vivo dosimetry system, using p-type diode dosimeters, was characterized for clinical applications of treatment machines ranging in megavoltage energies. This paper investigates two different models of diodes for externally wedged beams and explains a new algorithm for the calculation of the target dose at various tissue depths in external radiotherapy. The values of off-axis wedge correction factors were determined at two different positions in the wedged (toward the thick and thin edges and in the non-wedged directions on entrance and exit surfaces of a polystyrene phantom in 60 Co and 6 MV photon beams. Depth transmission was defined on the entrance and exit surfaces to obtain the off-axis wedge correction factor at any depth. As the sensitivity of the diodes depends on physical characteristics [field size, source-skin distance (SSD, thickness, backscatter], correction factors were applied to the diode reading when measuring conditions different from calibration situations . The results indicate that needful correction factors for 60 Co wedged photons are usually larger than those for 6 MV wedged photon beams. In vivo dosimetry performed with the proposed algorithms at externally wedged beams has negligible probable errors (less than 0.5% and is a reliable method for patient dose control.

  8. Evaluation of wedge-shaped phantoms for assessment of scanner display as a part of quality control of scanner performance

    International Nuclear Information System (INIS)

    Bergmann, H.; Havlik, E.

    1981-01-01

    Image manipulation in modern rectilinear scanners comprises background subtraction and contrast enhancement facilities. It has been the aim of this investigation to develop simple quality assurance methods suitable for checking the function of these features on a routine basis. Several types of phantoms have been investigated: an absorption step wedge, an emission step wedge and an emission continuous wedge. The absorption step wedge when used with a usual gamma-camera checking source gave the least satisfactory results. The emission step wedge is best suited for test procedures for background subtraction of the colour printer display and for contrast enhancement of the photo display, whereas the emission continuous wedge gave best results in testing the contrast enhancement of the colour printer display. An evaluation of the relative merits of the phantoms indicates that the emission step wedge is best suited for quality assurance tests. (author)

  9. Wedge and subselective pulmonary angiography in pulmonary hypertension secondary to venous obstruction

    International Nuclear Information System (INIS)

    Bowen, J.S.; Bookstein, J.J.; Johnson, A.D.; Peterson, K.L.; Moser, K.M.

    1985-01-01

    Pulmonary wedge or subselective angiography provided key diagnostic information in two cases of pulmonary hypertension secondary to pulmonary venous obstruction. Whereas conventional pulmonary angiograms and ventilation-perfusion lung scans were interpreted as showing embolism, plain radiographs demonstrated Kerley B lines, suggesting venous obstruction. Subselective or wedge angiography of nonopacified arteries verified their anatomical patency and also revealed venous stenoses, collaterals, and atrophy indicative of obstruction

  10. Radiographic Outcomes Following Lateral Column Lengthening With a Porous Titanium Wedge.

    Science.gov (United States)

    Gross, Christopher E; Huh, Jeannie; Gray, Joni; Demetracopoulos, Constantine; Nunley, James A

    2015-08-01

    Lateral column lengthening (LCL) is commonly utilized in treating stage II posterior tibialis tendon dysfunction. This study aimed to analyze the outcomes of LCL with porous titanium wedges compared to historic controls of iliac crest autograft and allograft. We hypothesized that the use of a porous titanium wedge would have radiographic improvement and union rates similar to those with the use of autograft and allograft in LCL. Between May 2009 and May 2014, 28 feet in 26 patients were treated with LCL using a porous titanium wedge. Of the 26 patients, 9 were males (34.6%). The average age for males was 43 years (range, 17.9-58.7), 48.7 years (range, 21-72.3) for females. Mean follow-up was 14.6 months. Radiographs were examined for correction of the flatfoot deformity and forefoot abduction. All complications were noted. Radiographically, the patients had a significant deformity correction in the anteroposterior talo-first metatarsal angle, talonavicular coverage angle, lateral talo-first metatarsal angle, and calcaneal pitch. All but 1 patient (96%) had bony incorporation of the porous titanium wedge. The average preoperative visual analog scale pain score was 5; all patients but 3 (12%) had improvements in their pain score, with a mean change of 3.4. LCL with porous titanium had low nonunion rates, improved radiographic correction, and pain relief. Level IV, case series. © The Author(s) 2015.

  11. Checks for quality control of wedge dynamics in treatment units and the planning system

    International Nuclear Information System (INIS)

    Mateos Salvador, P.; Rodriguez Lopez, B.; Font Gelabert, J.; Hernandez Rodriguez, J.; Arino Gil, A.

    2013-01-01

    The objective of this study is to verify the implementation of enhanced dynamic wedge (EDW) vary in the Eclipse planning system and the experimental determination of the parameters that define the dosimetry characteristics of enhanced dynamic wedge of our treatment units. (Author)

  12. Cone-Beam CT with Flat-Panel-Detector Digital Angiography System: Early Experience in Abdominal Interventional Procedures

    International Nuclear Information System (INIS)

    Hirota, Shozo; Nakao, Norio; Yamamoto, Satoshi; Kobayashi, Kaoru; Maeda, Hiroaki; Ishikura, Reiichi; Miura, Koui; Sakamoto, Kiyoshi; Ueda, Ken; Baba, Rika

    2006-01-01

    We developed a cone-beam computed tomography (CBCT) system equipped with a large flat-panel detector. Data obtained by 200 o rotation imaging are reconstructed by means of CBCT to generate three-dimensional images. We report the use of CBCT angiography using CBCT in 10 patients with 8 liver malignancies and 2 hypersplenisms during abdominal interventional procedures. CBCT was very useful for interventional radiologists to confirm a perfusion area of the artery catheter wedged on CT by injection of contrast media through the catheter tip, although the image quality was slightly degraded, scoring as 2.60 on average by streak artifacts. CBCT is space-saving because it does not require a CT system with a gantry, and it is also time-saving because it does not require the transfer of patients

  13. Forces in Motzkin paths in a wedge

    International Nuclear Information System (INIS)

    Janse van Rensburg, E J

    2006-01-01

    Entropic forces in models of Motzkin paths in a wedge geometry are considered as models of forces in polymers in confined geometries. A Motzkin path in the square lattice is a path from the origin to a point in the line Y = X while it never visits sites below this line, and it is constrained to give unit length steps only in the north and east directions and steps of length √2 in the north-east direction. Motzkin path models may be generalized to ensembles of NE-oriented paths above the line Y = rX, where r > 0 is an irrational number. These are paths giving east, north and north-east steps from the origin in the square lattice, and confined to the r-wedge formed by the Y-axis and the line Y = rX. The generating function g r of these paths is not known, but if r > 1, then I determine its radius of convergence to be t r = min (r-1)/r≤y≤r/(r+1) [y y (1-r(1-y)) 1-r(1-y) (r(1-y)-y) r(1-y)-y ] and if r is an element of (0, 1), then t r = 1/3. The entropic force the path exerts on the line Y rX may be computed from this. An asymptotic expression for the force for large values of r is given by F(r) = log(2r)/r 2 - (1+2log(2r))/2r 3 + O (log(2r)/r 4 ). In terms of the vertex angle α of the r-wedge, the moment of the force about the origin has leading terms F(α) log(2/α) - (α/2)(1+2log(2/α)) + O(α 2 log(2/α)) as α → 0 + and F(α) = 0 if α is element of [π/4, π/2]. Moreover, numerical integration of the force shows that the total work done by closing the wedge is 1.085 07... lattice units. An alternative ensemble of NE-oriented paths may be defined by slightly changing the generating function g r . In this model, it is possible to determine closed-form expressions for the limiting free energy and the force. The leading term in an asymptotic expansions for this force agrees with the leading term in the asymptotic expansion of the above model, and the subleading term only differs by a factor of 2

  14. Comments related to infinite wedge representations

    OpenAIRE

    Grieve, Nathan

    2016-01-01

    We study the infinite wedge representation and show how it is related to the universal extension of $g[t,t^{-1}]$ the loop algebra of a complex semi-simple Lie algebra $g$. We also give an elementary proof of the boson-fermion correspondence. Our approach to proving this result is based on a combinatorial construction with partitions combined with an application of the Murnaghan-Nakayama rule.

  15. Climate adaptation wedges: a case study of premium wine in the western United States

    Energy Technology Data Exchange (ETDEWEB)

    Diffenbaugh, Noah [Stanford University; White, Michael A [Utah State University (USU); Jones, Gregory V [Southern Oregon University, Ashland, OR; Ashfaq, Moetasim [ORNL

    2011-01-01

    Design and implementation of effective climate change adaptation activities requires quantitative assessment of the impacts that are likely to occur without adaptation, as well as the fraction of impact that can be avoided through each activity. Here we present a quantitative framework inspired by the greenhouse gas stabilization wedges of Pacala and Socolow. In our proposed framework, the damage avoided by each adaptation activity creates an 'adaptation wedge' relative to the loss that would occur without that adaptation activity. We use premium winegrape suitability in the western United States as an illustrative case study, focusing on the near-term period that covers the years 2000 39. We find that the projected warming over this period results in the loss of suitable winegrape area throughout much of California, including most counties in the high-value North Coast and Central Coast regions. However, in quantifying adaptation wedges for individual high-value counties, we find that a large adaptation wedge can be captured by increasing the severe heat tolerance, including elimination of the 50% loss projected by the end of the 2030 9 period in the North Coast region, and reduction of the projected loss in the Central Coast region from 30% to less than 15%. Increased severe heat tolerance can capture an even larger adaptation wedge in the Pacific Northwest, including conversion of a projected loss of more than 30% in the Columbia Valley region of Washington to a projected gain of more than 150%. We also find that warming projected over the near-term decades has the potential to alter the quality of winegrapes produced in the western US, and we discuss potential actions that could create adaptation wedges given these potential changes in quality. While the present effort represents an initial exploration of one aspect of one industry, the climate adaptation wedge framework could be used to quantitatively evaluate the opportunities and limits of climate

  16. Climate adaptation wedges: a case study of premium wine in the western United States

    International Nuclear Information System (INIS)

    Diffenbaugh, Noah S; Ashfaq, Moetasim; White, Michael A; Jones, Gregory V

    2011-01-01

    Design and implementation of effective climate change adaptation activities requires quantitative assessment of the impacts that are likely to occur without adaptation, as well as the fraction of impact that can be avoided through each activity. Here we present a quantitative framework inspired by the greenhouse gas stabilization wedges of Pacala and Socolow. In our proposed framework, the damage avoided by each adaptation activity creates an 'adaptation wedge' relative to the loss that would occur without that adaptation activity. We use premium winegrape suitability in the western United States as an illustrative case study, focusing on the near-term period that covers the years 2000-39. We find that the projected warming over this period results in the loss of suitable winegrape area throughout much of California, including most counties in the high-value North Coast and Central Coast regions. However, in quantifying adaptation wedges for individual high-value counties, we find that a large adaptation wedge can be captured by increasing the severe heat tolerance, including elimination of the 50% loss projected by the end of the 2030-9 period in the North Coast region, and reduction of the projected loss in the Central Coast region from 30% to less than 15%. Increased severe heat tolerance can capture an even larger adaptation wedge in the Pacific Northwest, including conversion of a projected loss of more than 30% in the Columbia Valley region of Washington to a projected gain of more than 150%. We also find that warming projected over the near-term decades has the potential to alter the quality of winegrapes produced in the western US, and we discuss potential actions that could create adaptation wedges given these potential changes in quality. While the present effort represents an initial exploration of one aspect of one industry, the climate adaptation wedge framework could be used to quantitatively evaluate the opportunities and limits of climate adaptation

  17. Assessment of Neutron Contamination Originating from the Presence of Wedge and Block in Photon Beam Radiotherapy.

    Science.gov (United States)

    Bahreyni Toossi, M T; Khajetash, B; Ghorbani, M

    2018-03-01

    One of the main causes of induction of secondary cancer in radiation therapy is neutron contamination received by patients during treatment. Objective: In the present study the impact of wedge and block on neutron contamination production is investigated. The evaluations are conducted for a 15 MV Siemens Primus linear accelerator. Simulations were performed using MCNPX Monte Carlo code. 30˚, 45˚ and 60˚ wedges and a cerrobend block with dimensions of 1.5 × 1.5 × 7 cm 3 were simulated. The investigation were performed in the 10 × 10 cm 2 field size at source to surface distance of 100 cm for depth of 0.5, 2, 3 and 4 cm in a water phantom. Neutron dose was calculated using F4 tally with flux to dose conversion factors and F6 tally. Results showed that the presence of wedge increases the neutron contamination when the wedge factor was considered. In addition, 45˚ wedge produced the most amount of neutron contamination. If the block is in the center of the field, the cerrobend block caused less neutron contamination than the open field due to absorption of neutrons and photon attenuation. The results showed that neutron contamination is less in steeper depths. The results for two tallies showed practically equivalent results. Wedge causes neutron contamination hence should be considered in therapeutic protocols in which wedge is used. In terms of clinical aspects, the results of this study show that superficial tissues such as skin will tolerate more neutron contamination than the deep tissues.

  18. Spacing of Imbricated Thrust Faults and the Strength of Thrust-Belts and Accretionary Wedges

    Science.gov (United States)

    Ito, G.; Regensburger, P. V.; Moore, G. F.

    2017-12-01

    The pattern of imbricated thrust blocks is a prominent characteristic of the large-scale structure of thrust-belts and accretionary wedges around the world. Mechanical models of these systems have a rich history from laboratory analogs, and more recently from computational simulations, most of which, qualitatively reproduce the regular patterns of imbricated thrusts seen in nature. Despite the prevalence of these patterns in nature and in models, our knowledge of what controls the spacing of the thrusts remains immature at best. We tackle this problem using a finite difference, particle-in-cell method that simulates visco-elastic-plastic deformation with a Mohr-Coulomb brittle failure criterion. The model simulates a horizontal base that moves toward a rigid vertical backstop, carrying with it an overlying layer of crust. The crustal layer has a greater frictional strength than the base, is cohesive, and is initially uniform in thickness. As the layer contracts, a series of thrust blocks immerge sequentially and form a wedge having a mean taper consistent with that predicted by a noncohesive, critical Coulomb wedge. The widths of the thrust blocks (or spacing between adjacent thrusts) are greatest at the front of the wedge, tend to decrease with continued contraction, and then tend toward a pseudo-steady, minimum width. Numerous experiments show that the characteristic spacing of thrusts increases with the brittle strength of the wedge material (cohesion + friction) and decreases with increasing basal friction for low (laws that will illuminate the basic physical processes controlling systems, as well as allow researchers to use observations of thrust spacing as an independent constraint on the brittle strength of wedges as well as their bases.

  19. Reduced emissions of greenhouse gases 2050: Technological wedges - Input to the Commission on Low Emissions

    International Nuclear Information System (INIS)

    Rosenberg, Eva; Espegren, Kari Aamodt; Finden, Per; Hageman, Rolf; Stenersen, Dag

    2006-09-01

    The Commission on Low Emissions was established in March 2005 and has been charged with the task of describing how Norway can achieve a 50-80 percent reduction in emissions of greenhouse gases by 2050. The commission describes the desired total reduction in emissions to be a set of actions or 'wedges', meaning that the reduction in emissions are linked to an array of technological and behavioural changes. The technological wedges are described here, while the behavioural wedges are treated in a different report. The potentials described are based on the Low Emission's reference line. Possible changes in the reference line will result in changed potentials. The technological wedges studied comprise to a great extent a potential of 50-80 percent reduction in greenhouse gases by 2050. This depends on considerable effort from research and development, and a determination to change external conditions

  20. A quantum hybrid with a thin antenna at the vertex of a wedge

    Energy Technology Data Exchange (ETDEWEB)

    Carlone, Raffaele, E-mail: raffaele.carlone@unina.it [Università “Federico II” di Napoli, Dipartimento di Matematica e Applicazioni “R. Caccioppoli”, MSA, via Cinthia, I-80126, Napoli (Italy); Posilicano, Andrea, E-mail: andrea.posilicano@uninsubria.it [DiSAT, Università dell' Insubria, via Valleggio 11, I-22100, Como (Italy)

    2017-03-26

    We study the spectrum, resonances and scattering matrix of a quantum Hamiltonian on a “hybrid surface” consisting of a half-line attached by its endpoint to the vertex of a concave planar wedge. At the boundary of the wedge, outside the vertex, homogeneous Dirichlet conditions are imposed. The system is tunable by varying the measure of the angle at the vertex. - Highlights: • Spectral characterization of a quantum Hamiltonian on “hybrid surface” consisting of a halfline attached to the vertex of a concave planar wedge. • The system is tunable by varying the measure of the angle at the vertex. • Relation between the conduction properties inside the hybrid and formation of resonances. • Easy generalization of the results to more complicated structures.

  1. Interaction of Structure and Physical Properties in Accretionary Wedges: Examples from the Cascadia and Nankai Trough Subduction Zones

    Science.gov (United States)

    Webb, Susanna I.

    Subduction zones are capable of producing large, megathrust earthquakes that are sometimes tsunamigenic. Structure and physical properties in the accretionary wedge play a role in how far rupture can propagate and how the wedge deforms coseismically. In this dissertation, I use seismic reflection data and velocity models from the Cascadia subduction zone and logging data from the Nankai Trough, Japan, to interpret structure, link structure to the broader wedge deformation history, and investigate the material properties at depth. I present a full structural interpretation of newly acquired seismic reflection data in the central Cascadia margin, which is characterized by dominantly landward vergent faulting in the outer wedge, a very low wedge taper angle, and a broad, lightly deformed lower slope terrace. Two decollements are active: an upper decollement within the sedimentary section, and a basal decollement at the sediment-basement interface. These interpretations help delineate the spatial extent of decollements and suggest that supra-wedge sedimentation may influence the development of the wedge, including the formation of the lower slope terrace and out of sequence fault activity. I use velocity models from central Cascadia to estimate excess pore fluid pressure and overpressure ratio at depth, which do not exceed 5 MPa and 0.15, respectively. No excess pore pressure is documented in the underthrust sediment section, but modest overpressure is likely present in the incoming sediment section and the footwalls of thrust sheets. The analysis of pore pressure shows that (1) if the base of the wedge is weak, it is due to mechanical properties of the sediments or a relatively thin underthrust layer and (2) the Cascadia wedge is relatively well-drained, and thus potentially strong, which can lead to a low wedge taper angle. In the Nankai Trough, Japan, I reprocessed sonic log data to obtain P-wave and S-wave velocity values and estimate elastic moduli. The logs

  2. Elastic wave diffraction by infinite wedges

    Energy Technology Data Exchange (ETDEWEB)

    Fradkin, Larissa; Zernov, Victor [Sound Mathematics Ltd., Cambridge CB4 2AS (United Kingdom); Gautesen, Arthur [Mathematics Department, Iowa State University and Ames Laboratory (United States); Darmon, Michel, E-mail: l.fradkin@soundmathematics.com [CEA-LIST, CEA-Saclay, 91191 Gif-sur-Yvette (France)

    2011-01-01

    We compare two recently developed semi-analytical approaches to the classical problem of diffraction by an elastic two dimensional wedge, one based on the reciprocity principle and Fourier Transform and another, on the representations of the elastodynamic potentials in the form of Sommerfeld Integrals. At present, in their common region of validity, the approaches are complementary, one working better than the other at some isolated angles of incidence.

  3. Study and evaluation of the Siemens virtual wedge factor: dosimetric monitor system and variable field effects

    Energy Technology Data Exchange (ETDEWEB)

    Sendon Rio, J R Sendon; Martinez, C Otero; GarcIa, M Sanchez; Busto, R Lobato; Vega, V Luna; Sueiro, J Mosquera; Camean, M Pombar [Servizo de Radiofisica e Proteccion Radioloxica, Complexo Hospitalario Universitario de Santiago de Compostela (CHUS), Santiago de Compostela (Spain)], E-mail: jose.ramon.sendon.del.rio@sergas.es

    2008-03-07

    In the year 1997 Siemens introduced the virtual wedge in its accelerators. The idea was that a dose profile similar to that of a physical wedge can be obtained by moving one of the accelerator jaws at a constant speed while the dose rate is changing. This work explores the observed behaviour of virtual wedge factors. A model is suggested which takes into account that at any point in time, when the jaw moves, the dose at a point of interest in the phantom is not only due to the direct beam. It also depends on the scattered radiation in the phantom, the head scatter and the behaviour of the monitoring system of the accelerator. Measurements are performed in a Siemens Primus accelerator and compared to the model predictions. It is shown that the model agrees reasonably well with measurements spanning a wide range of conditions. A strong dependence of virtual wedge factors on the dosimetric board has been confirmed and an explanation has been given on how the balance between different contributions is responsible for virtual wedge factors values.

  4. Filling Transitions in Acute and Open Wedges.

    Czech Academy of Sciences Publication Activity Database

    Malijevský, Alexandr; Parry, A.O.

    2015-01-01

    Roč. 91, č. 5 (2015), s. 052401 ISSN 1539-3755 R&D Projects: GA ČR GA13-09914S Grant - others:EPSRC(GB) EP/J009636/1; EPSRC(GB) EP/I019111/1 Institutional support: RVO:67985858 Keywords : wetting transitions * wedges * density functional theory Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 2.288, year: 2014

  5. Fixed Points of Maps of a Nonaspherical Wedge

    Directory of Open Access Journals (Sweden)

    Merrill Keith

    2009-01-01

    Full Text Available Abstract Let be a finite polyhedron that has the homotopy type of the wedge of the projective plane and the circle. With the aid of techniques from combinatorial group theory, we obtain formulas for the Nielsen numbers of the selfmaps of .

  6. A multisatellite case study of the expansion of a substorm current wedge in the near-Earth magnetotail

    International Nuclear Information System (INIS)

    Lopez, R.E.; Lui, A.T.Y.

    1990-01-01

    This study presents observations made by four spacecraft (AMPTE CCE, AMPTE IRM, GOES 5, and GOES 6) and two ground stations (San Juan and Tucson) during a substorm that occurred at ∼0830 UT on April 19, 1985. The spacecraft were arrayed in a configuration that allows for the examination of the spatial evolution of the substorm current wedge, CCE was located between the GOES spacecraft in longitude, but at a radial distance of 8.0 R E . IRM was located west of the other three spacecraft in the same sector as Tucson, but at a radial distance of 11.6 R E . The relative times at which the signature of the substorm current wedge was first observed at the GOES spacecraft and the ground stations are consistent with a simple longitudinally expanding current wedge. However, the times at which IRM and CCE observed the current wedge are not consistent with a current wedge that expanded only longitudinally, IRM first observed the signature of the current wedge at about the same time the signature was observed by GOES 6 and Tucson, and CCE observed the current wedge only after both GOES satellites and the ground stations had done so. Moreover, both GOES spacecraft observed signatures consistent with entry into the central plasma sheet before CCE and IRM did, even though we estimate that CCE was slightly closer to the neutral sheet than the geosynchronous spacecraft. The sequence of events suggests that during this substorm the disruption of the cross-tail current sheet, the formation of the substorm current wedge, and the expansion of the plasma sheet began in the near-Earth region, and subsequently spread tailward as well as longitudinally

  7. Partially wedged beams improve radiotherapy treatment of urinary bladder cancer

    International Nuclear Information System (INIS)

    Muren, Ludvig Paul; Hafslund, Rune; Gustafsson, Anders; Smaaland, Rune; Dahl, Olav

    2001-01-01

    Background and purpose: Partially wedged beams (PWBs) having wedge in one part of the field only, can be shaped using dynamic jaw intensity modulation. The possible clinical benefit of PWBs was tested in treatment plans for muscle-infiltrating bladder cancer. Material and methods: Three-dimensional treatment plans for 25 bladder cancer patients were analyzed. The originally prescribed standard conformal four-field box technique, which includes the use of lateral ordinary wedge beams, was compared to a modified conformal treatment using customized lateral PWBs. In these modified treatment plans, only the anterior parts of the two lateral beams had a wedge. To analyze the potential clinical benefit of treatment with PWBs, treatment plans were scored and compared using both physical parameters and biological dose response models. One tumour control probability model and two normal tissue complication probability (NTCP) models were applied. Different parameters for normal tissue radiation tolerance presented in the literature were used. Results: By PWBs the dose homogeneity throughout the target volume was improved for all patients, reducing the average relative standard deviation of the target dose distribution from 2.3 to 1.8%. A consistent reduction in the maximum doses to surrounding normal tissue volumes was also found. The most notable improvement was demonstrated in the rectum where the volume receiving more than the prescribed tumour dose was halved. Treatment with PWBs would permit a target dose escalation of 2-6 Gy in several of the patients analyzed, without increasing the overall risk for complications. The number of patients suitable for dose escalation ranged from 3 to 15, depending on whether support from all or only one of the five applied NTCP model/parameter combinations were required in each case to recommend dose escalation. Conclusion: PWBs represent a simple dose conformation tool that may allow radiation dose escalation in the treatment of muscle

  8. Thermal regime of an ice-wedge polygon landscape near Barrow, Alaska

    Science.gov (United States)

    Daanen, R. P.; Liljedahl, A. K.

    2017-12-01

    Tundra landscapes are changing all over the circumpolar Arctic due to permafrost degradation. Soil cracking and infilling of meltwater repeated over thousands of years form ice wedges, which produce the characteristic surface pattern of ice-wedge polygon tundra. Rapid top-down thawing of massive ice leads to differential ground subsidence and sets in motion a series of short- and long-term hydrological and ecological changes. Subsequent responses in the soil thermal regime drive further permafrost degradation and/or stabilization. Here we explore the soil thermal regime of an ice-wedge polygon terrain near Utqiagvik (formerly Barrow) with the Water balance Simulation Model (WaSiM). WaSiM is a hydro-thermal model developed to simulate the water balance at the watershed scale and was recently refined to represent the hydrological processes unique to cold climates. WaSiM includes modules that represent surface runoff, evapotranspiration, groundwater, and soil moisture, while active layer freezing and thawing is based on a direct coupling of hydrological and thermal processes. A new snow module expands the vadose zone calculations into the snow pack, allowing the model to simulate the snow as a porous medium similar to soil. Together with a snow redistribution algorithm based on local topography, this latest addition to WaSiM makes simulation of the ground thermal regime much more accurate during winter months. Effective representation of ground temperatures during winter is crucial in the simulation of the permafrost thermal regime and allows for refined predictions of future ice-wedge degradation or stabilization.

  9. Ice-Wedge Polygon Formation Impacts Permafrost Carbon Storage and Vulnerability to Top-Down Thaw in Arctic Coastal Plain Soils

    Science.gov (United States)

    Jastrow, J. D.; Matamala, R.; Ping, C. L.; Vugteveen, T. W.; Lederhouse, J. S.; Michaelson, G. J.; Mishra, U.

    2017-12-01

    Ice-wedge polygons are ubiquitous, patterned ground features throughout Arctic coastal plains and river deltas. The progressive expansion of ice wedges influences polygon development and strongly affects cryoturbation and soil formation. Thus, we hypothesized that polygon type impacts the distribution and composition of soil organic carbon (C) stocks across the landscape and that such information can improve estimates of permafrost C stocks vulnerable to active layer thickening and increased decomposition due to climatic change. We quantified the distribution of soil C across entire polygon profiles (2-m depth) for three developmental types - flat-centered (FCP), low-centered (LCP), and high-centered (HCP) polygons (3 replicates of each) - formed on glaciomarine sediments within and near the Barrow Environmental Observatory at the northern tip of Alaska. Active layer thickness averaged 45 cm and did not vary among polygon types. Similarly, active layer C stocks were unaffected by polygon type, but permafrost C stocks increased from FCPs to LCPs to HCPs despite greater ice volumes in HCPs. These differences were due to a greater presence of organic horizons in the upper permafrost of LCPs and, especially, HCPs. On average, C stocks in polygon interiors were double those of troughs, on a square meter basis. However, HCPs were physically smaller than LCPs and FCPs, which affected estimates of C stocks at the landscape scale. Accounting for the number of polygons per unit area and the proportional distribution of troughs versus interiors, we estimated permafrost C stocks (2-m depth) increased from 259 Mg C ha-1 in FCPs to 366 Mg C ha-1 in HCPs. Active layer C stocks did not differ among polygon types and averaged 328 Mg C ha-1. We used our detailed polygon profiles to investigate the impact of active layer deepening as projected by Earth system models under future climate scenarios. Because HCPs have a greater proportion of upper permafrost C stocks in organic horizons

  10. Use of a wedge cuvette in thin layer photometry and its application to oximetry

    NARCIS (Netherlands)

    Spaan, J. A.; Garred, L. J.; van de Borne, P.

    1977-01-01

    A wedge cuvette was constructed by fixing 2 glass plates at a known angle with a spacer at one end. This resulted in a thin layer with thickness varying from 0 to 250 micrometer. By measuring the intensity of a beam of light through the thin layer as a function of distance along the wedge (and thus

  11. Direct FVM Simulation for Sound Propagation in an Ideal Wedge

    Directory of Open Access Journals (Sweden)

    Hongyu Ji

    2016-01-01

    Full Text Available The sound propagation in a wedge-shaped waveguide with perfectly reflecting boundaries is one of the few range-dependent problems with an analytical solution. This provides a benchmark for the theoretical and computational studies on the simulation of ocean acoustic applications. We present a direct finite volume method (FVM simulation for the ideal wedge problem, and both time and frequency domain results are analyzed. We also study the broadband problem with large-scale parallel simulations. The results presented in this paper validate the accuracy of the numerical techniques and show that the direct FVM simulation could be applied to large-scale complex acoustic applications with a high performance computing platform.

  12. Design of a digital beam attenuation system for computed tomography. Part II. Performance study and initial results

    International Nuclear Information System (INIS)

    Szczykutowicz, Timothy P.; Mistretta, Charles A.

    2013-01-01

    Purpose: The purpose of this work is to present a performance study of the digital beam attenuator (DBA) for implementing fluence field modulated CT (FFMCT) using a simulation framework developed to model the incorporation of the DBA into an existing CT system. Additionally, initial results will be presented using a prototype DBA and the realization of the prototype will be described. To our knowledge, this study represents the first experimental use of a device capable of modulating x-ray fluence as a function of fan angle using a CT geometry. Methods: To realize FFMCT, the authors propose to use a wedge design in which one wedge is held stationary and another wedge is moved over the stationary wedge. Due to the wedge shape, the composite thickness of the two wedges changes as a function of the amount of overlap between the wedges. This design allows for the wedges to modulate the photon fluence incident onto a patient. Using a simulation environment, the effect of changing the number of wedges has on dose, scatter, detector dynamic range, and noise uniformity is explored. Experimental results are presented using a prototype DBA having ten Fe wedges and a c-arm CT system geometry. The experimental DBA results are compared to non-DBA scans using scatter and detector dynamic range as metrics. Both flat field and bowtie filtered CT acquisitions were simulated for comparison with the DBA. Results: Numerical results suggest that substantial gains in noise uniformity and scatter-to-primary ratio (SPR) can be obtained using only seven wedges. After seven wedges, the decrease in noise ununiformity and SPR falls off at a lower rate. Simulations comparing CT acquisitions between flat field, bowtie enabled, and DBA CT acquisitions suggest DBA-FFMCT can reduce dose relative to flat field CT by ≈3 times. A bowtie filter under the same imaging conditions was shown to only allow a dose reduction of 1.65 times. Experimentally, a 10 wedge DBA prototype result showed a SPR

  13. Measurement of dynamic wedge angles and beam profiles by means of MRI ferrous sulphate gel dosimetry

    Science.gov (United States)

    Bengtsson, Magnus; Furre, Torbjørn; Rødal, Jan; Skretting, Arne; Olsen, Dag R.

    1996-02-01

    The purpose of this study is to examine the possible value of measuring the dose distribution in dynamic wedge photon beams using ferrous sulphate gel phantoms analysed by MRI. The wedge angles and dose profiles were measured for a field size of and for dynamic wedge angles of , , and using a 15 MV photon beam generated from a Clinac 2100 CD (Varian). The dose profiles obtained from MRI ferrous sulphate gel were in good agreement with the dose measurements performed with a diode detector array. Also, the wedge angles determined from the MRI ferrous sulphate gel agreed well with the values obtained by using film dosimetry and with calculations by use of TMS (treatment planning system) (Helax, Uppsala, Sweden). The study demonstrated that MRI ferrous sulphate gel dosimetry is an adequate tool for measurements of some beam characteristics of dynamic radiation fields.

  14. Flow Analysis for the Falkner–Skan Wedge Flow

    DEFF Research Database (Denmark)

    Bararnia, H; Haghparast, N; Miansari, M

    2012-01-01

    In this article an analytical technique, namely the homotopy analysis method (HAM), is applied to solve the momentum and energy equations in the case of a two-dimensional incompressible flow passing over a wedge. The trail and error method and Padé approximation strategies have been used to obtai...

  15. Three-dimensional semi-analytical solution to groundwater flow in confined and unconfined wedge-shaped aquifers

    Science.gov (United States)

    Sedghi, Mohammad Mahdi; Samani, Nozar; Sleep, Brent

    2009-06-01

    The Laplace domain solutions have been obtained for three-dimensional groundwater flow to a well in confined and unconfined wedge-shaped aquifers. The solutions take into account partial penetration effects, instantaneous drainage or delayed yield, vertical anisotropy and the water table boundary condition. As a basis, the Laplace domain solutions for drawdown created by a point source in uniform, anisotropic confined and unconfined wedge-shaped aquifers are first derived. Then, by the principle of superposition the point source solutions are extended to the cases of partially and fully penetrating wells. Unlike the previous solution for the confined aquifer that contains improper integrals arising from the Hankel transform [Yeh HD, Chang YC. New analytical solutions for groundwater flow in wedge-shaped aquifers with various topographic boundary conditions. Adv Water Resour 2006;26:471-80], numerical evaluation of our solution is relatively easy using well known numerical Laplace inversion methods. The effects of wedge angle, pumping well location and observation point location on drawdown and the effects of partial penetration, screen location and delay index on the wedge boundary hydraulic gradient in unconfined aquifers have also been investigated. The results are presented in the form of dimensionless drawdown-time and boundary gradient-time type curves. The curves are useful for parameter identification, calculation of stream depletion rates and the assessment of water budgets in river basins.

  16. Effects of Flat Slab Subduction on Andean Thrust Kinematics and Foreland Basin Evolution in Western Argentina

    Science.gov (United States)

    Horton, B. K.; Fuentes, F.; McKenzie, N. R.; Constenius, K. N.; Alvarado, P. M.

    2014-12-01

    Debate persists over the effects of flat-slab subduction on the kinematics of overriding plate deformation and the evolution of retroarc sedimentary basins. In western Argentina, major spatial and temporal variations in the geometry of the subducting Nazca slab since ~15 Ma provide opportunities to evaluate the late Cenozoic response of the Andean fold-thrust belt and foreland basin to subhorizontal subduction. Preliminary results from several structural and sedimentary transects spanning the frontal thrust belt and foreland basin system between 31°S and 35°S reveal Oligocene-middle Miocene hinterland exhumation during normal-slab subduction followed thereafter by progressive slab shallowing with initial rapid cratonward propagation of ramp-flat thrust structures (prior to basement-involved foreland uplifts) and accompanying wholesale exhumation and recycling of the early Andean foreland basin (rather than regional dynamic subsidence). Detrital zircon U-Pb geochronologic data prove instrumental for revealing shifts in thrust-belt exhumation, defining depositional ages within the foreland basin, and constraining the timing of activity along frontal thrust structures. In both the San Juan (31-32°S) and Malargüe (34-35°S) segments of the fold-thrust belt, geochronological results for volcaniclastic sandstones and syndeformational growth strata are consistent with a major eastward advance in shortening at 12-9 Ma. This episode of rapid thrust propagation precedes the reported timing of Sierras Pampeanas basement-involved foreland uplifts and encompasses modern regions of both normal- and flat-slab subduction, suggesting that processes other than slab dip (such as inherited crustal architecture, critical wedge dynamics, and arc magmatism) are additional regulators of thrust-belt kinematics and foreland basin evolution.

  17. Uniform physical theory of diffraction equivalent edge currents for truncated wedge strips

    DEFF Research Database (Denmark)

    Johansen, Peter Meincke

    1996-01-01

    New uniform closed-form expressions for physical theory of diffraction equivalent edge currents are derived for truncated incremental wedge strips. In contrast to previously reported expressions, the new expressions are well behaved for all directions of incidence and observation and take a finite...... value for zero strip length. This means that the expressions are well suited for implementation in general computer codes. The new expressions are expressed as the difference between two terms. The first term is obtained by integrating the exact fringe wave current on a wedge along an untruncated...

  18. Dose conformation to the spine during palliative treatments using dynamic wedges

    Energy Technology Data Exchange (ETDEWEB)

    Ormsby, Matthew A., E-mail: Matthew.Ormsby@usoncology.com [West Texas Cancer Center at Medical Center Hospital, Odessa, TX (United States); Herndon, R. Craig; Kaczor, Joseph G. [West Texas Cancer Center at Medical Center Hospital, Odessa, TX (United States)

    2013-07-01

    Radiation therapy is commonly used to alleviate pain associated with metastatic disease of the spine. Often, isodose lines are manipulated using dynamic or physical wedges to encompass the section of spine needing treatment while minimizing dose to normal tissue. We will compare 2 methods used to treat the entire thoracic spine. The first method treats the thoracic spine with a single, nonwedged posterior-anterior (PA) field. Dose is prescribed to include the entire spine. Isodose lines tightly conform to the top and bottom vertebrae, but vertebrae between these 2 received more than enough coverage. The second method uses a combination of wedges to create an isodose line that mimics the curvature of the thoracic spine. This “C”-shaped curvature is created by overlapping 2 fields with opposing dynamic wedges. Machine constraints limit the treatment length and therefore 2 isocenters are used. Each of the 2 PA fields contributes a portion of the total daily dose. This technique creates a “C”-shaped isodose line that tightly conforms to the thoracic spine, minimizing normal tissue dose. Spinal cord maximum dose is reduced, as well as mean dose to the liver, esophagus, and heart.

  19. Cementless Hip Stem Anteversion in the Dysplastic Hip: A Comparison of Tapered Wedge vs Metaphyseal Filling.

    Science.gov (United States)

    Taniguchi, Naofumi; Jinno, Tetsuya; Koga, Daisuke; Hagino, Tetsuo; Okawa, Atsushi; Haro, Hirotaka

    2017-05-01

    Appropriate stem anteversion is important for achieving stability of the prosthetic joint in total hip arthroplasty. Anteversion of a cementless femoral stem is affected by the femoral canal morphology and varies according to stem geometry. We investigated the difference and variation of the increase in anteversion between 2 types of cementless stems, and the correlation between each stem and the preoperative femoral anteversion. We retrospectively compared 2 groups of hips that underwent total hip arthroplasty using a metaphyseal filling stem (78 hips) or a tapered wedge stem (83 hips). All the patients had osteoarthritis due to hip dysplasia. Computed tomography was used to measure preoperative femoral anteversion at 5 levels and postoperative stem anteversion. The increase in anteversion of the tapered wedge stem group (22.7° ± 11.6°) was more than that of the metaphyseal filling stem group (17.2° ± 8.3°; P = .0007). The variation of the increase in the tapered wedge stem group was significantly larger than that in the metaphyseal filling stem group (P = .0016). The metaphyseal filling stem group was more highly and positively correlated with femoral anteversion than the tapered wedge stem group. Femoral anteversion affects stem anteversion differently according to stem geometry. The tapered wedge stems had greater variation of the increase in anteversion than did the metaphyseal filling stems. Based on the results of this study, it is difficult to preoperatively estimate the increase in stem anteversion for tapered wedge stems. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Linking Serpentinite Geochemistry with Possible Alteration and Evolution of Supra-Subduction Wedge Mantle

    Science.gov (United States)

    Scambelluri, M.; Cannaò, E.; Agostini, S.; Gilio, M.

    2016-12-01

    Serpentinites are able to transport and release volatiles and fluid-mobile elements (FME) found in arc magmas. Constraining the trace element compositions of these rocks and of fluids released by de-serpentinization improves our knowledge of mass transfer from subduction zones to volcanic arcs, and of the role of slab and wedge mantle in this global process. Studies of high-pressure ultramafic rocks exhumed from plate interface settings reveal the fluid/rock interactions atop the slab and the processes that can affect the mantle wedge. Alpine eclogite-facies antigorite serpentinite (Voltri Massif) and fully de-serpentinized meta-peridotite (Cima di Gagnone) are enriched in sediment-derived As, Sb, U, Pb before peak dehydration. Their Sr, Pb and B isotopic compositions are reset during prograde (forearc) interaction with slab fluids. The eclogitic garnet and olivine from the Cima di Gagnone metaperidotite trap primary inclusions of the fluid released during breakdown of antigorite and chlorite. The inclusions display FME enrichments (high Cl, S; variable Cs, Rb, Ba, B, Pb, As, Sb) indicating element release from rocks to fluids during dehydration under subarc conditions. Our studies show that serpentinized mantle rocks from subduction zones sequester FME from slab fluids and convey these components and radiogenic isotopes into the mantle wedge upon dehydration. The geochemical processes revealed by such plate-interface rocks can apply to the supra-subduction mantle. Shallow element release from slabs to mantle wedge, downdrag of this altered mantle and its subsequent (subarc) dehydration transfers crust-derived FMEs to the arc magma sources without the need of concomitant subarc dehydration/melting of metasedimentary slab components. The slab signature detected in arc lavas can thus result from geochemical mixing of sediment, oceanic crust and ultramafic reservoirs into altered wedge-mantle rocks, rather than being attributed to multiple fluids.

  1. Proximal Opening Wedge Osteotomy Provides Satisfactory Midterm Results With a Low Complication Rate.

    Science.gov (United States)

    Oravakangas, Rami; Leppilahti, Juhana; Laine, Vesa; Niinimäki, Tuukka

    2016-01-01

    Hallux valgus is one of the most common foot deformities. Proximal opening wedge osteotomy is used for the treatment of moderate and severe hallux valgus with metatarsus primus varus. However, hypermobility of the first tarsometatarsal joint can compromise the results of the operation, and a paucity of midterm results are available regarding proximal open wedge osteotomy surgery. The aim of the present study was to assess the midterm results of proximal open wedge osteotomy in a consecutive series of patients with severe hallux valgus. Thirty-one consecutive adult patients (35 feet) with severe hallux valgus underwent proximal open wedge osteotomy. Twenty patients (35.5%) and 23 feet (34.3%) were available for the final follow-up examination. The mean follow-up duration was 5.8 (range 4.6 to 7.0) years. The radiologic measurements and American Orthopaedic Foot and Ankle Society hallux-metatarsophalangeal-interphalangeal scores were recorded pre- and postoperatively, and subjective questionnaires were completed and foot scan analyses performed at the end of the follow-up period. The mean hallux valgus angle decreased from 38° to 23°, and the mean intermetatarsal angle correction decreased from 17° to 10°. The mean improvement in the American Orthopaedic Foot and Ankle Society hallux metatarsophalangeal-interphalangeal score increased from 52 to 84. Two feet (5.7%) required repeat surgery because of recurrent hallux valgus. No nonunions were identified. Proximal open wedge osteotomy provided satisfactory midterm results in the treatment of severe hallux valgus, with a low complication rate. The potential instability of the first tarsometatarsal joint does not seem to jeopardize the midterm results of the operation. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  2. An IBEM solution to the scattering of plane SH-waves by a lined tunnel in elastic wedge space

    Science.gov (United States)

    Liu, Zhongxian; Liu, Lei

    2015-02-01

    The indirect boundary element method (IBEM) is developed to solve the scattering of plane SH-waves by a lined tunnel in elastic wedge space. According to the theory of single-layer potential, the scattered-wave field can be constructed by applying virtual uniform loads on the surface of lined tunnel and the nearby wedge surface. The densities of virtual loads can be solved by establishing equations through the continuity conditions on the interface and zero-traction conditions on free surfaces. The total wave field is obtained by the superposition of free field and scattered-wave field in elastic wedge space. Numerical results indicate that the IBEM can solve the diffraction of elastic wave in elastic wedge space accurately and efficiently. The wave motion feature strongly depends on the wedge angle, the angle of incidence, incident frequency, the location of lined tunnel, and material parameters. The waves interference and amplification effect around the tunnel in wedge space is more significant, causing the dynamic stress concentration factor on rigid tunnel and the displacement amplitude of flexible tunnel up to 50.0 and 17.0, respectively, more than double that of the case of half-space. Hence, considerable attention should be paid to seismic resistant or anti-explosion design of the tunnel built on a slope or hillside.

  3. Characterizing and configuring motorized wedge for a new generation telecobalt machine in a treatment planning system

    Directory of Open Access Journals (Sweden)

    Kinhikar Rajesh

    2007-01-01

    Full Text Available A new generation telecobalt unit, Theratron Equinox-80, (MDS Nordion, Canada has been evaluated. It is equipped with a single 60-degree motorized wedge (MW, four universal wedges (UW for 150, 300, 450 and 600. MW was configured in Eclipse (Varian, Palo Alto, USA 3D treatment planning system (TPS. The profiles and central axis depth doses (CADD were measured with radiation field analyzer blue water phantom for MW. These profiles and CADD for MW were compared with UW in a homogeneous phantom generated in Eclipse for various field sizes. The absolute dose was measured for a field size of 10 x 10 cm2 only in a MEDTEC water phantom at 10 cm depth with a 0.13 cc thimble ion chamber (Scanditronix Wellhofer, Uppsala, Sweden and a NE electrometer (Nuclear Enterprises, UK. Measured dose with ion chamber was compared with the TPS predicted dose. MW angle was verified on the Equinox for four angles (15o, 30o, 45o and 60o. The variation in measured and calculated dose at 10 cm depth was within 2%. The measured and the calculated wedge angles were in well agreement within 2o. The motorized wedges were successfully configured in Eclipse for four wedge angles.

  4. Modes of continental extension in a crustal wedge

    KAUST Repository

    Wu, Guangliang

    2015-07-01

    © 2015 Elsevier B.V. We ran numerical experiments of the extension of a crustal wedge as an approximation to extension in an orogenic belt or a continental margin. We study the effects of the strength of the lower crust and of a weak mid-crustal shear zone on the resulting extension styles. A weak mid-crustal shear zone effectively decouples upper crustal extension from lower crustal flow. Without the mid-crustal shear zone, the degree of coupling between the upper and the lower crust increases and extension of the whole crust tends to focus on the thickest part of the wedge. We identify three distinct modes of extension determined by the strength of the lower crust, which are characterized by 1) localized, asymmetric crustal exhumation in a single massif when the lower crust is weak, 2) the formation of rolling-hinge normal faults and the exhumation of lower crust in multiple core complexes with an intermediate strength lower crust, and 3) distributed domino faulting over the weak mid-crustal shear zone when the lower crust is strong. A frictionally stronger mid-crustal shear zone does not change the overall model behaviors but extension occurred over multiple rolling-hinges. The 3 modes of extension share characteristics similar to geological models proposed to explain the formation of metamorphic core complexes: 1) the crustal flow model for the weak lower crust, 2) the rolling-hinge and crustal flow models when the lower crust is intermediate and 3) the flexural uplift model when the lower crust is strong. Finally we show that the intensity of decoupling between the far field extension and lower crustal flow driven by the regional pressure gradient in the wedge control the overall style of extension in the models.

  5. Modes of continental extension in a crustal wedge

    KAUST Repository

    Wu, Guangliang; Lavier, Luc L.; Choi, Eunseo

    2015-01-01

    © 2015 Elsevier B.V. We ran numerical experiments of the extension of a crustal wedge as an approximation to extension in an orogenic belt or a continental margin. We study the effects of the strength of the lower crust and of a weak mid-crustal shear zone on the resulting extension styles. A weak mid-crustal shear zone effectively decouples upper crustal extension from lower crustal flow. Without the mid-crustal shear zone, the degree of coupling between the upper and the lower crust increases and extension of the whole crust tends to focus on the thickest part of the wedge. We identify three distinct modes of extension determined by the strength of the lower crust, which are characterized by 1) localized, asymmetric crustal exhumation in a single massif when the lower crust is weak, 2) the formation of rolling-hinge normal faults and the exhumation of lower crust in multiple core complexes with an intermediate strength lower crust, and 3) distributed domino faulting over the weak mid-crustal shear zone when the lower crust is strong. A frictionally stronger mid-crustal shear zone does not change the overall model behaviors but extension occurred over multiple rolling-hinges. The 3 modes of extension share characteristics similar to geological models proposed to explain the formation of metamorphic core complexes: 1) the crustal flow model for the weak lower crust, 2) the rolling-hinge and crustal flow models when the lower crust is intermediate and 3) the flexural uplift model when the lower crust is strong. Finally we show that the intensity of decoupling between the far field extension and lower crustal flow driven by the regional pressure gradient in the wedge control the overall style of extension in the models.

  6. Dehydration of chlorite explains anomalously high electrical conductivity in the mantle wedges.

    Science.gov (United States)

    Manthilake, Geeth; Bolfan-Casanova, Nathalie; Novella, Davide; Mookherjee, Mainak; Andrault, Denis

    2016-05-01

    Mantle wedge regions in subduction zone settings show anomalously high electrical conductivity (~1 S/m) that has often been attributed to the presence of aqueous fluids released by slab dehydration. Laboratory-based measurements of the electrical conductivity of hydrous phases and aqueous fluids are significantly lower and cannot readily explain the geophysically observed anomalously high electrical conductivity. The released aqueous fluid also rehydrates the mantle wedge and stabilizes a suite of hydrous phases, including serpentine and chlorite. In this present study, we have measured the electrical conductivity of a natural chlorite at pressures and temperatures relevant for the subduction zone setting. In our experiment, we observe two distinct conductivity enhancements when chlorite is heated to temperatures beyond its thermodynamic stability field. The initial increase in electrical conductivity to ~3 × 10(-3) S/m can be attributed to chlorite dehydration and the release of aqueous fluids. This is followed by a unique, subsequent enhancement of electrical conductivity of up to 7 × 10(-1) S/m. This is related to the growth of an interconnected network of a highly conductive and chemically impure magnetite mineral phase. Thus, the dehydration of chlorite and associated processes are likely to be crucial in explaining the anomalously high electrical conductivity observed in mantle wedges. Chlorite dehydration in the mantle wedge provides an additional source of aqueous fluid above the slab and could also be responsible for the fixed depth (120 ± 40 km) of melting at the top of the subducting slab beneath the subduction-related volcanic arc front.

  7. Perturbation solutions for flow through symmetrical hoppers with inserts and asymmetrical wedge hoppers

    Science.gov (United States)

    Cox, G. M.; Mccue, S. W.; Thamwattana, N.; Hill, J. M.

    Under certain circumstances, an industrial hopper which operates under the "funnel-flow" regime can be converted to the "mass-flow" regime with the addition of a flow-corrective insert. This paper is concerned with calculating granular flow patterns near the outlet of hoppers that incorporate a particular type of insert, the cone-in-cone insert. The flow is considered to be quasi-static, and governed by the Coulomb-Mohr yield condition together with the non-dilatant double-shearing theory. In two-dimensions, the hoppers are wedge-shaped, and as such the formulation for the wedge-in-wedge hopper also includes the case of asymmetrical hoppers. A perturbation approach, valid for high angles of internal friction, is used for both two-dimensional and axially symmetric flows, with analytic results possible for both leading order and correction terms. This perturbation scheme is compared with numerical solutions to the governing equations, and is shown to work very well for angles of internal friction in excess of 45°.

  8. Analysis of Mechanical Energy Transport on Free-Falling Wedge during Water-Entry Phase

    Directory of Open Access Journals (Sweden)

    Wen-Hua Wang

    2012-01-01

    Full Text Available For better discussing and understanding the physical phenomena and body-fluid interaction of water-entry problem, here mechanical-energy transport (wedge, fluid, and each other of water-entry model for free falling wedge is studied by numerical method based on free surface capturing method and Cartesian cut cell mesh. In this method, incompressible Euler equations for a variable density fluid are numerically calculated by the finite volume method. Then artificial compressibility method, dual-time stepping technique, and Roe's approximate Riemann solver are applied in the numerical scheme. Furthermore, the projection method of momentum equations and exact Riemann solution are used to calculate the fluid pressure on solid boundary. On this basis, during water-entry phase of the free-falling wedge, macroscopic energy conversion of overall body-fluid system and microscopic energy transformation in fluid field are analyzed and discussed. Finally, based on test cases, many useful conclusions about mechanical energy transport for water entry problem are made and presented.

  9. Complex Anisotropic Structure of the Mantle Wedge Beneath Kamchatka Volcanoes

    Science.gov (United States)

    Levin, V.; Park, J.; Gordeev, E.; Droznin, D.

    2002-12-01

    A wedge of mantle material above the subducting lithospheric plate at a convergent margin is among the most dynamic environments of the Earth's interior. Deformation and transport of solid and volatile phases within this region control the fundamental process of elemental exchange between the surficial layers and the interior of the planet. A helpful property in the study of material deformation and transport within the upper mantle is seismic anisotropy, which may reflect both microscopic effects of preferentialy aligned crystals of olivine and orthopyroxene and macroscopic effects of systematic cracks, melt lenses, layering etc. Through the mapping of anisotropic properties within the mantle wedge we can establish patterns of deformation. Volatile content affects olivine alignment, so regions of anomalous volatile content may be evident. Indicators of seismic anisotropy commonly employed in upper mantle studies include shear wave birefringence and mode-conversion between compressional and shear body waves. When combined together, these techniques offer complementary constraints on the location and intensity of anisotropic properties. The eastern coast of southern Kamchatka overlies a vigorous convergent margin where the Pacific plate descends at a rate of almost 80 mm/yr towards the northwest. We extracted seismic anisotropy indicators from two data sets sensitive to the anisotropic properties of the uppermost mantle. Firstly, we evaluated teleseismic receiver functions for a number of sites, and found ample evidence for anisotropicaly-influenced P-to-S mode conversion. Secondly, we measured splitting in S waves of earthquakes with sources within the downgoing slab. The first set of observations provides constraints on the depth ranges where strong changes in anisotropic properties take place. The local splitting data provides constraints on the cumulative strength of anisotropic properties along specific pathways through the mantle wedge and possibly parts of

  10. Effect of shape and resistivity of electrodes in a Faraday MHD duct

    International Nuclear Information System (INIS)

    Jayakumar, R.; Ghosh, S.

    1976-01-01

    The object of achieving uniform current distribution in the presence of high axial fields has prompted the use of resistive electrodes in flat and wedge geometries. In the case of flat geometry the technique involves the generation of voltage drop along the surface of the electrodes in the axial direction, due to the Faraday current collected by the electrode and flowing into a lead wire, to reduce or eliminate the discontinuity in the axial electrical field that would otherwise occur, say in case of metal electrodes. In the case of wedge shapes, higher resistance path is provided for the regions where current is likely to concentrate. In the case of flat geometry, the effect of the position of lead wire also influences the current distribution in the plasma and on the electrode surface. The resistive electrodes have been investigated for the actual current distribution by numerically solving the Laplace's equation for current stream function, arising out of Maxwell's equation and generalised Ohm's law. In the case of wedge electrode, the solution has been sought by numerical analysis of both plasma and electrode zones. It is shown that both geometries, the flat geometry with a lead wire shifted optimally from one edge and the wedge electrode can almost eliminate current concentration. (author)

  11. The solar photovoltaics wedge: pathways for growth and potential carbon mitigation in the US

    Energy Technology Data Exchange (ETDEWEB)

    Drury, Easan; Denholm, Paul [National Renewable Energy Laboratory, 1617 Cole Boulevard, Golden, CO 80401 (United States); Margolis, Robert M, E-mail: easan.drury@nrel.go [National Renewable Energy Laboratory, 901 D Street SW, Suite 930, Washington, DC 20024 (United States)

    2009-09-15

    The challenge of stabilizing global carbon emissions over the next 50 years has been framed in the context of finding seven 1.0 Gton C/year carbon reduction wedges. Solar photovoltaics (PV) could provide at least one carbon wedge, but will require significant growth in PV manufacturing capacity. The actual amount of installed PV capacity required to reach wedge-level carbon reductions will vary greatly depending on the mix of avoided fuels and the additional emissions from manufacturing PV capacity. In this work, we find that the US could reduce its carbon emissions by 0.25 Gton C/year, equal to the fraction of a global carbon wedge proportional to its current domestic electricity use, by installing 792-811 GW of PV capacity. We evaluate a series of PV growth scenarios and find that wedge-level reductions could be met by increasing PV manufacturing capacity and annual installations by 0.95 GW/year/year each year from 2009 to 2050 or by increasing up to 4 GW/year/year for a period of 4-17 years for early and late growth scenarios. This challenge of increasing PV manufacturing capacity and market demand is significant but not out of line with the recent rapid growth in both the global and US PV industry. We find that the rapid growth in PV manufacturing capacity leads to a short term increase in carbon emissions from the US electric sector. However, this increase is small, contributing less than an additional 0.3% to electric sector emissions for less than 4.5 years, alleviating recent concern regarding carbon emissions from rapid PV growth scenarios.

  12. Monoplanar versus biplanar medial open-wedge proximal tibial osteotomy for varus gonarthrosis: a comparison of clinical and radiological outcomes.

    Science.gov (United States)

    Elmalı, Nurzat; Esenkaya, Irfan; Can, Murat; Karakaplan, Mustafa

    2013-12-01

    We compared clinical and radiological results of two proximal tibial osteotomy (PTO) techniques: monoplanar medial open-wedge osteotomy and biplanar retrotubercle medial open-wedge osteotomy, stabilised by a wedged plate. We evaluated 88 knees in 78 patients. Monoplanar medial open-wedge PTO was performed on 56 knees in 50 patients with a mean age of 55 ± 9 years. Biplanar retrotubercle medial open-wedge PTO was performed on 32 knees in 28 patients with a mean age of 57 ± 7 years. Mean follow-up periods were 40.6 ± 7 months for the monoplanar PTO group and 38 ± 5 months for the biplanar retrotubercle PTO group. Clinical outcome was evaluated using the hospital for special surgery scoring system, and radiological outcome was evaluated by the measurements of femorotibial angle (FTA), patellar height and tibial slope changes. In both groups, post-operative HSS scores increased significantly. No significant difference was found between groups in FTA alteration, but the FTA decreased significantly in both groups. Patellar index ratios decreased significantly in the monoplanar PTO group (Insall-Salvati Index by 0.07, Blackburne-Peel Index by 0.07), but not in the biplanar retrotubercle PTO group. Tibial slopes were increased significantly in the monoplanar PTO group, but not in the retrotubercle PTO group. Biplanar retrotubercle medial open-wedge osteotomy and monoplanar medial open-wedge osteotomy are both clinically effective for the treatment for varus gonarthrosis. Retrotubercle osteotomy also prevents patella infera and tibial slope changes radiologically.

  13. Imaging of tuberculosis. Pt. 5. Peripheral osteoarticular and soft-tissue tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Hugosson, C. [Dept. of Radiology, King Faisal Specialist Hospital and Research Centre, Riyadh (Saudi Arabia); Nyman, R.S. [Dept. of Radiology, King Faisal Specialist Hospital and Research Centre, Riyadh (Saudi Arabia); Brismar, J. [Dept. of Radiology, King Faisal Specialist Hospital and Research Centre, Riyadh (Saudi Arabia); Larsson, S.G. [Dept. of Radiology, King Faisal Specialist Hospital and Research Centre, Riyadh (Saudi Arabia); Lindahl, S. [Dept. of Radiology, King Faisal Specialist Hospital and Research Centre, Riyadh (Saudi Arabia); Lundstedt, C. [Dept. of Radiology, King Faisal Specialist Hospital and Research Centre, Riyadh (Saudi Arabia)

    1996-07-01

    Purpose: To assess frequency, location, and appearance of peripheral osteoarticular and soft-tissue tuberculosis (TB). Material and Methods: Twenty-five of 503 patients with TB had peripheral osteoarticular TB and 5 had soft-tissue TB. Chest radiography, CT, and MR imaging were applied. Results: The location of the osteoarticular lesion was articular/epiphyseal in 14 patients, articular/metaphyseal in 3, and metaphyseal without joint involvement in 3. Involvement of flat bone was found in 4 patients (5 lesions). The morphologic appearance was similar to that of a lytic tumour in 9 patients (10 lesions) and that of a destructive joint lesion in 16 patients. The soft-tissue TB in all 5 patients presented as an abscess. Twelve patients had a total of 20 additional sites of involvement: Chest in 9, abdomen in 4, spine in 4, the neck in 3, and the central nervous system in one patient. Conclusion: On the basis of radiologic appearance, it can be difficult to differentiate peripheral osteoarticular and soft-tissue TB from other degenerative, inflammatory, or neoplastic disorders, and the importance of a high awareness is stressed in order to reach an early diagnosis. (orig.).

  14. Imaging of tuberculosis. Pt. 5. Peripheral osteoarticular and soft-tissue tuberculosis

    International Nuclear Information System (INIS)

    Hugosson, C.; Nyman, R.S.; Brismar, J.; Larsson, S.G.; Lindahl, S.; Lundstedt, C.

    1996-01-01

    Purpose: To assess frequency, location, and appearance of peripheral osteoarticular and soft-tissue tuberculosis (TB). Material and Methods: Twenty-five of 503 patients with TB had peripheral osteoarticular TB and 5 had soft-tissue TB. Chest radiography, CT, and MR imaging were applied. Results: The location of the osteoarticular lesion was articular/epiphyseal in 14 patients, articular/metaphyseal in 3, and metaphyseal without joint involvement in 3. Involvement of flat bone was found in 4 patients (5 lesions). The morphologic appearance was similar to that of a lytic tumour in 9 patients (10 lesions) and that of a destructive joint lesion in 16 patients. The soft-tissue TB in all 5 patients presented as an abscess. Twelve patients had a total of 20 additional sites of involvement: Chest in 9, abdomen in 4, spine in 4, the neck in 3, and the central nervous system in one patient. Conclusion: On the basis of radiologic appearance, it can be difficult to differentiate peripheral osteoarticular and soft-tissue TB from other degenerative, inflammatory, or neoplastic disorders, and the importance of a high awareness is stressed in order to reach an early diagnosis. (orig.)

  15. Application of Green's differential equation to the analysis of ion-matrix sheaths around wedge-shaped cathodes

    International Nuclear Information System (INIS)

    Donolato, C

    2005-01-01

    A relation between the gradient of the electric field and mean curvature of equipotential surfaces (Green's differential equation) is applied to a two-dimensional free-boundary problem arising in the study of ion sheaths around wedge-shaped cathodes. With the assumption that the equipotential lines are hyperbolae, this relation leads to a nonlinear ordinary differential equation for the potential along the bisector line of the wedge. An approximate solution is found, which yields, in particular, the sheath width along this line as a function of the wedge angle. The resulting values are in good agreement with published results obtained by numerically solving Poisson's equation

  16. Creating flat design websites

    CERN Document Server

    Pratas, Antonio

    2014-01-01

    This book contains practical, step-by-step tutorials along with plenty of explanation about designing your flat website. Each section is introduced sequentially, building up your web design skills and completing your website.Creating Flat Design Websites is ideal for you if you are starting on your web development journey, but this book will also benefit seasoned developers wanting to start developing in flat.

  17. 40 CFR 230.42 - Mud flats.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Mud flats. 230.42 Section 230.42... Aquatic Sites § 230.42 Mud flats. (a) Mud flats are broad flat areas along the sea coast and in coastal rivers to the head of tidal influence and in inland lakes, ponds, and riverine systems. When mud flats...

  18. Flat-space singletons

    International Nuclear Information System (INIS)

    Fronsdal, C.

    1987-01-01

    Singletons exist, as particles and as local fields, only in 3+2 de Sitter space. Their kinematical properties make them natural candidates for constituents of massless fields, and perhaps for quarks. It is interesting to find out how to describe this type of compositeness in flat space. A theory of interacting singleton fields in de Sitter space is now available, and in this paper we study the flat-space limit of the Green's functions of that theory. The flat-space limit is an autonomous theory of Green's functions, but is not an operator field theory. The three-point function is calculated and its flat-space limit is found to reveal glimpses of a physical interpretation. Causal and spectral properties are in accord with the tenets of axiomatic field theory. The theory is a generalization of local field theory, in which photons appear as composite objects although the physical S matrix is the same as in conventional QED

  19. Differential wedging of vertebral body and intervertebral disc in thoracic and lumbar spine in adolescent idiopathic scoliosis – A cross sectional study in 150 patients

    Directory of Open Access Journals (Sweden)

    Kim Hak-Jun

    2008-08-01

    Full Text Available Abstract Background Hueter-Volkmann's law regarding growth modulation suggests that increased pressure on the end plate of bone retards the growth (Hueter and conversely, reduced pressure accelerates the growth (Volkmann. Literature described the same principle in Rat-tail model. Human spine and its deformity i.e. scoliosis has also same kind of pattern during the growth period which causes wedging in disc or vertebral body. Methods This cross sectional study in 150 patients of adolescent idiopathic scoliosis was done to evaluate vertebral body and disc wedging in scoliosis and to compare the extent of differential wedging of body and disc, in thoracic and lumbar area. We measured wedging of vertebral bodies and discs, along with two adjacent vertebrae and disc, above and below the apex and evaluated them according to severity of curve (curve 30° to find the relationship of vertebral body or disc wedging with scoliosis in thoracic and lumbar spine. We also compared the wedging and rotations of vertebrae. Results In both thoracic and lumbar curves, we found that greater the degree of scoliosis, greater the wedging in both disc and body and the degree of wedging was more at apex supporting the theory of growth retardation in stress concentration area. However, the degree of wedging in vertebral body is more than the disc in thoracic spine while the wedging was more in disc than body in lumbar spine. On comparing the wedging with the rotation, we did not find any significant relationship suggesting that it has no relation with rotation. Conclusion From our study, we can conclude that wedging in disc and body are increasing with progression on scoliosis and maximum at apex; however there is differential wedging of body and disc, in thoracic and lumbar area, that is vertebral body wedging is more profound in thoracic area while disc wedging is more profound in lumbar area which possibly form 'vicious cycle' by asymmetric loading to spine for the

  20. The Oldman River triangle zone: a complicated tectonic wedge delineated by new structural mapping and seismic interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Stockmal, G. S. [Geological Survey of Canada, Calgary, AB (Canada). Inst. of Sedimentary and Petroleum Geology; Lawton, D. C.; Spratt, D. [Calgary Univ., AB (Canada). Dept. of Geology and Geophysics; MacKay, P. A.

    1996-06-01

    The triangle zone exposed along and adjacent to the Alberta Foothills was characterized on the basis of new structural mapping and seismic surveys. Results indicate that the zone is comprised of a complicated structure involving significant deformation in the hanging wall of the upper detachment, including orogenic thrusts and large orogen-vergent folds, as well as secondary orogen-directed tectonic wedging. This structure is considered to be an example of a `nested` triangle zone, where an `outer` tectonic wedge with modest shortening encases an `inner` counterpart with substantially more shortening. Both of these wedges show evidence of synchronous deformation. 23 refs., 9 figs.

  1. A paired wedge filter system for compensation in dose differences

    International Nuclear Information System (INIS)

    Kobayashi, H.; Sakurai, Y.; Kondo, S.; Abe, S.; Hayakawa, N.; Aoyama, Y.; Obata, Y.; Ishigaki, T.

    1998-01-01

    Objective: In radiotherapy, it is important to conform the high dose volume to the planned target volume. A variable thickness paired wedge filter system was developed to compensate for dose inhomogeneity arising from field width segment variation in conformal irradiation. Materials and methods: The present study used a 6 MV linear accelerator equipped with multileaf collimator leaves and a paired wedge compensating filter system. The dose variation due to field width was measured in each field segment width. The variation in attenuation of the compensators was measured as a function of filter position. As the field width increases, the relative absorbed dose also increases; this is the point of requiring compensation, so it can be in reverse proportion. Results: As the field width increases, the relative absorbed dose also increases; this is why compensation is required and thus it must be in reverse proportion. Attenuation of the absorbed dose by the paired filters was in proportion to the filter position. The filter position to compensate for the difference of absorbed doses was defined by the square root of the field width. For a field varying in width from 4 to 16 cm, the variation in the absorbed dose across the field was reduced from 12% to 2.7%. Conclusion: This paired wedge filter system reduced absorbed dose variations across multileaf collimator shaped fields and can facilitate treatment planning in conformal therapy. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  2. Complex Wedge-Shaped Matrices: A Generalization of Jacobi Matrices

    Czech Academy of Sciences Publication Activity Database

    Hnětynková, Iveta; Plešinger, M.

    2015-01-01

    Roč. 487, 15 December (2015), s. 203-219 ISSN 0024-3795 R&D Projects: GA ČR GA13-06684S Keywords : eigenvalues * eigenvector * wedge-shaped matrices * generalized Jacobi matrices * band (or block) Krylov subspace methods Subject RIV: BA - General Mathematics Impact factor: 0.965, year: 2015

  3. Kinematic segmentation of accretive wedges based on scaled sandbox experiments and their application to nature

    Science.gov (United States)

    Lohrmann, J.; Kukowski, N.; Oncken, O.

    2003-04-01

    Recording the incremental displacement field of scaled analogue simulations provides detailed data on wedge kinematics and timing of internal deformation. This is a very efficient tool to develop kinematic concepts and test mechanical theories, e.g. the critical-taper theory. Such models could not be validated until now by the available geological and geophysical data, since there was no information about the incremental displacement field. Recent GPS measurements and seismological investigations at convergent margins provide well-constrained strain-rates and kinematics of short-termed processes. These data allow the kinematic models that are based on analogue simulations to be tested against field observations. We investigate convergent accretive sand wedges in scaled analogue simulations. We define three kinematic segments based on distinctive wedge taper, displacement field and timing of deformation (recorded at a slow sampling rate, which represents the geological scale). Only one of these segments is in a critical state of stress, whereas the other segments are either in a sub-critical or stable state of stress. Such a kinematic segmentation is not predicted for ideally homogeneous wedge-shaped bodies by the critical-taper theory, but can be explained by the formation of localised weak shear zones, which preferentially accommodate deformation. These weak zones are formed in granular analogue materials, and also in natural rocks, since these materials show a strain-softening phase prior to the achievement of stable mechanical conditions. Therefore we suggest that the kinematic segmentation of convergent sand wedges should also be observed in natural settings, such as accretionary wedges, foreland fold-and-thrust belts and even entire orogens. To validate this hypothesis we compare strain rates from GPS measurements and kinematics deduced from focal mechanisms with the respective data from sandbox experiments. We present a strategy to compare strain rates and

  4. Measurement of Rayleigh Wave Beams Using Angle Beam Wedge Transducers as the Transmitter and Receiver with Consideration of Beam Spreading.

    Science.gov (United States)

    Zhang, Shuzeng; Li, Xiongbing; Jeong, Hyunjo

    2017-06-20

    A theoretical model, along with experimental verification, is developed to describe the generation, propagation and reception of a Rayleigh wave using angle beam wedge transducers. The Rayleigh wave generation process using an angle beam wedge transducer is analyzed, and the actual Rayleigh wave sound source distributions are evaluated numerically. Based on the reciprocity theorem and considering the actual sound source, the Rayleigh wave beams are modeled using an area integral method. The leaky Rayleigh wave theory is introduced to investigate the reception of the Rayleigh wave using the angle beam wedge transducers, and the effects of the wave spreading in the wedge and transducer size are considered in the reception process. The effects of attenuations of the Rayleigh wave and leaky Rayleigh wave are discussed, and the received wave results with different sizes of receivers are compared. The experiments are conducted using two angle beam wedge transducers to measure the Rayleigh wave, and the measurement results are compared with the predictions using different theoretical models. It is shown that the proposed model which considers the wave spreading in both the sample and wedges can be used to interpret the measurements reasonably.

  5. SU-E-T-362: Enhanced Dynamic Wedge Output Factors for Varian 2300CD and the Case for a Reference Database

    International Nuclear Information System (INIS)

    Njeh, C

    2015-01-01

    Purpose: Dose inhomogeneity in treatment planning can be compensated using physical wedges. Enhanced dynamic wedges (EDW) were introduced by Varian to overcome some of the short comings of physical wedges. The objectives of this study were to measure EDW output factors for 6 MV and 20 MV photon energies for a Varian 2300CD. Secondly to review the literature in terms of published enhanced dynamic wedge output factors (EDWOF) for different Varian models and thereby adding credence to the case of the validity of reference databases. Methods: The enhanced dynamic wedge output factors were measured for the Varian 2300CD for both 6 MV and 20 MV photon energies. Twelve papers with published EDWOF for different Varian Linac models were found in the literature. Results: The EDWOF for 6 MV varied from 0.980 for a 5×5 cm 10 degree wedge to 0.424 for 20×20 cm 60 degree wedge. Similarly for 20 MV, the EDWOF varied from 0.986 for 5×5 cm 10 degree wedge to 0.529 for 20×20 cm 60 degree wedge. EDWOF are highly dependent on field size. Comparing our results with the published mean, we found an excellent agreement for 6 MV EDWOF with the percentage differences ranging from 0.01% to 0.57% with a mean of 0.03%. The coefficient of variation of published EDWOF ranged from 0.17% to 0.85% and 0.1% to 0.9% for the for 6 MV and 18MV photon energies respectively. This paper provides the first published EDWOF for 20 MV photon energy. In addition, we have provided the first compendium of EDWOFs for different Varian linac models. Conclusion: The consistency of EDWOF across models and institution provide further support that, a standard data set of basic photon and electron dosimetry could be established, as a guide for future commissioning, beam modeling and quality assurance purposes

  6. Flat slices in Minkowski space

    Science.gov (United States)

    Murchadha, Niall Ó.; Xie, Naqing

    2015-03-01

    Minkowski space, flat spacetime, with a distance measure in natural units of d{{s}2}=-d{{t}2}+d{{x}2}+d{{y}2}+d{{z}2}, or equivalently, with spacetime metric diag(-1, +1, +1, +1), is recognized as a fundamental arena for physics. The Poincaré group, the set of all rigid spacetime rotations and translations, is the symmetry group of Minkowski space. The action of this group preserves the form of the spacetime metric. Each t = constant slice of each preferred coordinate system is flat. We show that there are also nontrivial non-singular representations of Minkowski space with complete flat slices. If the embedding of the flat slices decays appropriately at infinity, the only flat slices are the standard ones. However, if we remove the decay condition, we find non-trivial flat slices with non-vanishing extrinsic curvature. We write out explicitly the coordinate transformation to a frame with such slices.

  7. Investigation of cell adhesion in chitosan membranes for peripheral nerve regeneration

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Cristiana R.; López-Cebral, Rita; Silva-Correia, Joana; Silva, Joana M.; Mano, João F.; Silva, Tiago H. [3B' s Research Group - Biomaterials, Biodegradables and Biomimetics, University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine, AvePark – Parque de Ciência e Tecnologia, 4805-017, Barco, Guimarães (Portugal); ICVS/3B' s - PT Government Associate Laboratory, Braga, Guimarães (Portugal); Freier, Thomas [MEDOVENT GmbH, Friedrich-Koenig-Str. 3, D-55129 Mainz (Germany); Reis, Rui L. [3B' s Research Group - Biomaterials, Biodegradables and Biomimetics, University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine, AvePark – Parque de Ciência e Tecnologia, 4805-017, Barco, Guimarães (Portugal); ICVS/3B' s - PT Government Associate Laboratory, Braga, Guimarães (Portugal); Oliveira, Joaquim M., E-mail: miguel.oliveira@dep.uminho.pt [3B' s Research Group - Biomaterials, Biodegradables and Biomimetics, University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine, AvePark – Parque de Ciência e Tecnologia, 4805-017, Barco, Guimarães (Portugal); ICVS/3B' s - PT Government Associate Laboratory, Braga, Guimarães (Portugal)

    2017-02-01

    Peripheral nerve injuries have produced major concerns in regenerative medicine for several years, as the recovery of normal nerve function continues to be a significant clinical challenge. Chitosan (CHT), because of its good biocompatibility, biodegradability and physicochemical properties, has been widely used as a biomaterial in tissue engineering scaffolding. In this study, CHT membranes were produced with three different Degrees of Acetylation (DA), envisioning its application in peripheral nerve regeneration. The three CHT membranes (DA I: 1%, DA II: 2%, DA III: 5%) were extensively characterized and were found to have a smooth and flat surface, with DA III membrane having slightly higher roughness and surface energy. All the membranes presented suitable mechanical properties and did not show any signs of calcification after SBF test. Biodegradability was similar for all samples, and adequate to physically support neurite outgrowth. The in vitro cell culture results indicate selective cell adhesion. The CHT membranes favoured Schwann cells invasion and proliferation, with a display of appropriate cytoskeletal morphology. At the same time they presented low fibroblast infiltration. This fact may be greatly beneficial for the prevention of fibrotic tissue formation, a common phenomenon impairing peripheral nerve regeneration. The great deal of results obtained during this work permitted to select the formulation with the greatest potential for further biological tests. - Highlights: • Three chitosan membranes were produced with very specific degrees of acetylation (DA I: 1%, DA II: 2%, DA III: 5%). • Physicochemical characterization of the membranes showed their suitability for peripheral nerve regeneration purposes. • In vitro cellular tests confirmed the potential of the membranes as peripheral nerve regeneration systems. • The results indicated that DA III membrane should be the one considered for further peripheral nerve regeneration studies.

  8. Investigation of cell adhesion in chitosan membranes for peripheral nerve regeneration

    International Nuclear Information System (INIS)

    Carvalho, Cristiana R.; López-Cebral, Rita; Silva-Correia, Joana; Silva, Joana M.; Mano, João F.; Silva, Tiago H.; Freier, Thomas; Reis, Rui L.; Oliveira, Joaquim M.

    2017-01-01

    Peripheral nerve injuries have produced major concerns in regenerative medicine for several years, as the recovery of normal nerve function continues to be a significant clinical challenge. Chitosan (CHT), because of its good biocompatibility, biodegradability and physicochemical properties, has been widely used as a biomaterial in tissue engineering scaffolding. In this study, CHT membranes were produced with three different Degrees of Acetylation (DA), envisioning its application in peripheral nerve regeneration. The three CHT membranes (DA I: 1%, DA II: 2%, DA III: 5%) were extensively characterized and were found to have a smooth and flat surface, with DA III membrane having slightly higher roughness and surface energy. All the membranes presented suitable mechanical properties and did not show any signs of calcification after SBF test. Biodegradability was similar for all samples, and adequate to physically support neurite outgrowth. The in vitro cell culture results indicate selective cell adhesion. The CHT membranes favoured Schwann cells invasion and proliferation, with a display of appropriate cytoskeletal morphology. At the same time they presented low fibroblast infiltration. This fact may be greatly beneficial for the prevention of fibrotic tissue formation, a common phenomenon impairing peripheral nerve regeneration. The great deal of results obtained during this work permitted to select the formulation with the greatest potential for further biological tests. - Highlights: • Three chitosan membranes were produced with very specific degrees of acetylation (DA I: 1%, DA II: 2%, DA III: 5%). • Physicochemical characterization of the membranes showed their suitability for peripheral nerve regeneration purposes. • In vitro cellular tests confirmed the potential of the membranes as peripheral nerve regeneration systems. • The results indicated that DA III membrane should be the one considered for further peripheral nerve regeneration studies.

  9. Duodenal Wedge Resection for Large Gastrointestinal Stromal Tumour Presenting with Life-Threatening Haemorrhage

    Directory of Open Access Journals (Sweden)

    Alexander Shaw

    2013-01-01

    Full Text Available Background. Duodenal gastrointestinal stromal tumours (GISTs are an uncommon malignancy of the gastrointestinal (GI tract. We present a case of life-threatening haemorrhage caused by a large ulcerating duodenal GIST arising from the third part of the duodenum managed by a limited duodenal wedge resection. Case Presentation. A 61-year-old patient presented with acute life-threatening gastrointestinal bleeding. After oesophagogastroduodenoscopy failed to demonstrate the source of bleeding, a 5 cm ulcerating exophytic mass originating from the third part of the duodenum was identified at laparotomy. A successful limited wedge resection of the tumour mass was performed. Histopathology subsequently confirmed a duodenal GIST. The patient remained well at 12-month followup with no evidence of local recurrence or metastatic spread. Conclusion. Duodenal GISTs can present with life-threatening upper GI haemorrhage. In the context of acute haemorrhage, even relatively large duodenal GISTs can be treated by limited wedge resection. This is a preferable alternative to duodenopancreatectomy with lower morbidity and mortality but comparable oncological outcome.

  10. Peripheral neuropathy

    Science.gov (United States)

    ... peripheral; Neuritis - peripheral; Nerve disease; Polyneuropathy; Chronic pain - peripheral neuropathy ... Philadelphia, PA: Elsevier; 2016:chap 107. Shy ME. Peripheral neuropathies. In: Goldman L, Schafer AI, eds. Goldman's Cecil ...

  11. Experimental Investigation on Cross Flow of Wedge-shaped Gap in the core of Prismatic VHTR

    International Nuclear Information System (INIS)

    Lee, Jeong Hun; Park, Goon Cherl; Cho, Hyoung Kyu; Yoon, Su Jong

    2014-01-01

    The core of the PMR type reactor consists of assemblies of hexagonal graphite blocks. The graphite blocks have lots of advantages for neutron economy and high temperature structural integrity. The height and flat-to-flat width of fuel bock are 793 mm and 360 mm, respectively. Each block has 108 coolant channels of which the diameter is 16 mm. And there are gaps between blocks not only vertically but also horizontally for reloading of the fuel elements. The vertical gap induces the bypass flow and through the horizontal gap the cross flow is formed. Since the complicated flow distribution occurs by the bypass flow and cross flow, flow characteristics in the core of the PMR reactor cannot be treated as a simple pipe flow. The fuel zone of the PMR core consists of multiple layers of fuel blocks. The shape change of the fuel blocks could be caused by the thermal expansion and fast-neutron induced shrinkage. It could make different axial shrinkage of fuel block and this leads to wedge-shaped gaps between two stacked fuel blocks. The cross flow is often considered as a leakage flow through the horizontal gap between stacked fuel blocks and it complicates the flow distribution in the reactor core by connecting the coolant channel and the bypass gap. Moreover, the cross flow could lead to uneven coolant distribution and consequently cause superheating of individual fuel element zones with increased fission product release. Since the core cross flow has a negative impact on safety and efficiency of VHTR, core cross flow phenomena have to be investigated to improve the core thermal margin of VHTR. To develop the cross flow loss coefficient model for determination of the flow distribution for PMR core analysis codes, study on cross flow for PMR200 core is essential. In particular, to predict the amount of flow through the cross flow gap, obtaining accurate flow loss coefficient is important. In this study, the full-scale cross flow experimental facility was constructed to

  12. Dependence of wedge transmission factor on co-60 teletherapy ...

    African Journals Online (AJOL)

    Measuring the wedge factor (WF) for radiation field of 10 x 10 cm2 at a specified depth and Source to Surface Distance (SSD), and applying the value to all treatment depths and technique could introduce errors > ± 5 % of threshold stipulated for patient radiation dose delivery. Therefore, some Treatment Planning Systems ...

  13. Thoracoscopic pulmonary wedge resection without post-operative chest drain

    DEFF Research Database (Denmark)

    Holbek, Bo Laksafoss; Hansen, Henrik Jessen; Kehlet, Henrik

    2016-01-01

    %) patients had a pneumothorax of mean size 12 ± 12 mm on supine 8-h post-operative X-ray for which the majority resolved spontaneously within 2-week control. There were no complications on 30-day follow-up. Median length of stay was 1 day. CONCLUSIONS: The results support that VATS wedge resection...

  14. 3D seismic investigation of the structural and stratigraphic characteristics of the Pagasa Wedge, Southwest Palawan Basin, Philippines, and their tectonic implications

    Science.gov (United States)

    Ilao, Kimberly A.; Morley, Christopher K.; Aurelio, Mario A.

    2018-04-01

    The Pagasa Wedge is a poorly imaged deepwater orogenic wedge that has been variously interpreted as representing an accretionary prism, a former accretionary prism modified by thrusting onto a thinned continental margin, and a gravity-driven fold-thrust belt. This study, using 2D and 3D seismic data, together with well information indicates that at least the external part of the wedge is dominantly composed of mass transport complexes, capped by syn-kinematic sediments that have thrusts and normal faults superimposed upon them. Drilling shows that despite stratigraphic repetition of Eocene Middle Miocene units, there is stratigraphic omission of Oligocene and Early Miocene units. This absence suggests that mass transport processes have introduced the Eocene section into the wedge rather than tectonic thrusting. The accretionary prism stage (Oligocene) of the Central Palawan Ophiolite history appears to be marked by predominantly north-vergent deformation. The Deep Regional Unconformity (∼17 Ma) likely indicates the approximate time when obduction ceased in Palawan. The Pagasa Wedge is a late-stage product of the convergence history that was active in its final phase sometime above the top of the Nido Limestone (∼16 Ma) and the base of the Tabon Limestone in the Aboabo-A1X well (∼9 Ma). The top of the wedge is traditionally associated with the Middle Miocene Unconformity (MMU), However the presence of multiple unconformities, diachronous formation tops, local tectonic unconformities and regional diachronous events (e.g. migrating forebulges) all suggest simply giving a single age (or assigning a single unconformity, such as the MMU as defining the top of the Pagasa Wedge is inappropriate. The overall NE-SW trend of the wedge, and the dominant NW transport of structures within the wedge diverge from the more northerly transport direction determined from outcrops in Palawan, and also from the Nido Limestone in the SW part of the Pagasa Wedge. Possibly this NW

  15. [Radiocarbon dating of pollen and spores in wedge ice from Iamal and Kolyma].

    Science.gov (United States)

    Vasil'chuk, A K

    2004-01-01

    Radiocarbon dating of pollen concentrate from late Pleistocene syngenetic wedge ice was carried out using acceleration mass spectrometry (AMS) in Seyakha and Bizon sections. Comparison of the obtained dating with palynological analysis and AMS radiocarbon dating previously obtained for other organic fractions of the same samples allowed us to evaluate accuracy of dating of different fractions. Quantitative tests for data evaluation were considered in terms of possible autochthonous or allochthonous accumulation of the material on the basis of pre-Pleistocene pollen content in these samples. Paleoecological information content of pollen spectra from late Pleistocene syngenetic wedge ice was evaluated.

  16. RANS Analyses of Turbofan Nozzles with Internal Wedge Deflectors for Noise Reduction

    Science.gov (United States)

    DeBonis, James R.

    2009-01-01

    Computational fluid dynamics (CFD) was used to evaluate the flow field and thrust performance of a promising concept for reducing the noise at take-off of dual-stream turbofan nozzles. The concept, offset stream technology, reduces the jet noise observed on the ground by diverting (offsetting) a portion of the fan flow below the core flow, thickening and lengthening this layer between the high-velocity core flow and the ground observers. In this study a wedge placed in the internal fan stream is used as the diverter. Wind, a Reynolds averaged Navier-Stokes (RANS) code, was used to analyze the flow field of the exhaust plume and to calculate nozzle performance. Results showed that the wedge diverts all of the fan flow to the lower side of the nozzle, and the turbulent kinetic energy on the observer side of the nozzle is reduced. This reduction in turbulent kinetic energy should correspond to a reduction in noise. However, because all of the fan flow is diverted, the upper portion of the core flow is exposed to the freestream, and the turbulent kinetic energy on the upper side of the nozzle is increased, creating an unintended noise source. The blockage due to the wedge reduces the fan mass flow proportional to its blockage, and the overall thrust is consequently reduced. The CFD predictions are in very good agreement with experimental flow field data, demonstrating that RANS CFD can accurately predict the velocity and turbulent kinetic energy fields. While this initial design of a large scale wedge nozzle did not meet noise reduction or thrust goals, this study identified areas for improvement and demonstrated that RANS CFD can be used to improve the concept.

  17. Pulmonary abnormalities in mitral valve disease. Comparison between pulmonary wedge pressure, regional pulmonary blood flow and chest films

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, L H; Andersen, Jr, P E [Odense Univ. (Denmark)

    1978-01-01

    Chest films, right sided heart catheterization, and measurement of the regional lung perfusion, using /sup 133/Xe, were carried out 31 times on patients with mitral valve disease. A relationship was found between the radiologic evaluation in 3 grades, and the values of pulmonary wedge pressure and the apical and basal perfusion. Changes in flow distribution as reflected in altered appearance of the vessels and the presence of interstitial edema were found to be the most sensitive factors in the evaluation of pulmonary wedge pressure. Chest radiography was thus found suitable for the evaluation of pulmonary wedge pressure in mitral valve disease.

  18. The effect of shoe design and lateral wedges on knee load and neuromuscular control in healthy subjects during walking

    DEFF Research Database (Denmark)

    Mølgaard, Carsten; Kersting, Uwe G.

    2014-01-01

    The increasing number of patients with developing osteoarthritis is accompanied by a growing scientific interest in non-operative early treatment strategies. It is generally believed that laterally wedged insoles can change the distribution of knee loading. However, the importance of footwear...... wedging is effective regardless of shoe design. Differences between the three neutral walking conditions underline the importance of footwear choice in individuals. It is safe to apply lateral wedges without jeopardising muscular control during walking regardless of shoe type. Possible effects of altering...

  19. Near-field flat focusing mirrors

    Science.gov (United States)

    Cheng, Yu-Chieh; Staliunas, Kestutis

    2018-03-01

    This article reviews recent progress towards the design of near-field flat focusing mirrors, focusing/imaging light patterns in reflection. An important feature of such flat focusing mirrors is their transverse invariance, as they do not possess any optical axis. We start with a review of the physical background to the different focusing mechanisms of near- and far-field focusing. These near-field focusing devices like flat lenses and the reviewed near-field focusing mirrors can implement planar focusing devices without any optical axis. In contrast, various types of far-field planar focusing devices, such as high-contrast gratings and metasurfaces, unavoidably break the transverse invariance due to their radially symmetrical structures. The particular realizations of near-field flat focusing mirrors including Bragg-like dielectric mirrors and dielectric subwavelength gratings are the main subjects of the review. The first flat focusing mirror was demonstrated with a chirped mirror and was shown to manage an angular dispersion for beam focusing, similar to the management of chromatic dispersion for pulse compression. Furthermore, the reviewed optimized chirped mirror demonstrated a long near-field focal length, hardly achieved by a flat lens or a planar hyperlens. Two more different configurations of dielectric subwavelength gratings that focus a light beam at normal or oblique incidence are also reviewed. We also summarize and compare focusing performance, limitations, and future perspectives between the reviewed flat focusing mirrors and other planar focusing devices including a flat lens with a negative-index material, a planar hyperlens, a high-contrast grating, and a metasurface.

  20. Intensity-Modulated Radiotherapy Results in Significant Decrease in Clinical Toxicities Compared With Conventional Wedge-Based Breast Radiotherapy

    International Nuclear Information System (INIS)

    Harsolia, Asif; Kestin, Larry; Grills, Inga; Wallace, Michelle; Jolly, Shruti; Jones, Cortney; Lala, Moinaktar; Martinez, Alvaro; Schell, Scott; Vicini, Frank A.

    2007-01-01

    Purpose: We have previously demonstrated that intensity-modulated radiotherapy (IMRT) with a static multileaf collimator process results in a more homogenous dose distribution compared with conventional wedge-based whole breast irradiation (WBI). In the present analysis, we reviewed the acute and chronic toxicity of this IMRT approach compared with conventional wedge-based treatment. Methods and Materials: A total of 172 patients with Stage 0-IIB breast cancer were treated with lumpectomy followed by WBI. All patients underwent treatment planning computed tomography and received WBI (median dose, 45 Gy) followed by a boost to 61 Gy. Of the 172 patients, 93 (54%) were treated with IMRT, and the 79 patients (46%) treated with wedge-based RT in a consecutive fashion immediately before this cohort served as the control group. The median follow-up was 4.7 years. Results: A significant reduction in acute Grade 2 or worse dermatitis, edema, and hyperpigmentation was seen with IMRT compared with wedges. A trend was found toward reduced acute Grade 3 or greater dermatitis (6% vs. 1%, p = 0.09) in favor of IMRT. Chronic Grade 2 or worse breast edema was significantly reduced with IMRT compared with conventional wedges. No difference was found in cosmesis scores between the two groups. In patients with larger breasts (≥1,600 cm 3 , n = 64), IMRT resulted in reduced acute (Grade 2 or greater) breast edema (0% vs. 36%, p <0.001) and hyperpigmentation (3% vs. 41%, p 0.001) and chronic (Grade 2 or greater) long-term edema (3% vs. 30%, p 0.007). Conclusion: The use of IMRT in the treatment of the whole breast results in a significant decrease in acute dermatitis, edema, and hyperpigmentation and a reduction in the development of chronic breast edema compared with conventional wedge-based RT

  1. Electromagnetic Scattering from a PEC Wedge Capped with Cylindrical Layers with Dielectric and Conductive Properties

    Directory of Open Access Journals (Sweden)

    H. Ozturk

    2017-04-01

    Full Text Available Electromagnetic scattering from a layered capped wedge is studied. The wedge is assumed infinite in z-direction (longitudinal and capped with arbitrary layers of dielectric with varying thicknesses and dielectric properties including conductive loss. Scalar Helmholtz equation in two dimensions is formulated for each solution region and a matrix of unknown coefficients are arrived at for electric field representation. Closed form expressions are derived for 2- and 3-layer geometries. Numerical simulations are performed for different wedge shapes and dielectric layer properties and compared to PEC-only case. It has been shown that significant reduction in scattered electric field can be obtained with 2- and 3-layered cap geometries. Total electric field in the far field normalized to incident field is also computed as a precursor to RCS analysis. Analytical results can be useful in radar cross section analysis for aerial vehicles.

  2. Integrated waste management as a climate change stabilisation wedge for the Maltese islands.

    Science.gov (United States)

    Falzon, Clyde; Fabri, Simon G; Frysinger, Steven

    2013-01-01

    The continuous increase in anthropogenic greenhouse gas emissions occurring since the Industrial Revolution is offering significant ecological challenges to Earth. These emissions are leading to climate changes which bring about extensive damage to communities, ecosystems and resources. The analysis in this article is focussed on the waste sector within the Maltese islands, which is the largest greenhouse gas emitter in the archipelago following the energy and transportation sectors. This work shows how integrated waste management, based on a life cycle assessment methodology, acts as an effective stabilisation wedge strategy for climate change. Ten different scenarios applicable to the Maltese municipal solid waste management sector are analysed. It is shown that the scenario that is most coherent with the stabilisation wedges strategy for the Maltese islands consists of 50% landfilling, 30% mechanical biological treatment and 20% recyclable waste export for recycling. It is calculated that 16.6 Mt less CO2-e gases would be emitted over 50 years by means of this integrated waste management stabilisation wedge when compared to the business-as-usual scenario. These scientific results provide evidence in support of policy development in Malta that is implemented through legislation, economic instruments and other applicable tools.

  3. Comparison of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease with Flat-Panel Detectors on Mobile C-arm versus Fixed Systems.

    Science.gov (United States)

    Guillou, Marie; Maurel, Blandine; Necib, Hatem; Vent, Pierre-Alexandre; Costargent, Alain; Chaillou, Philippe; Gouëffic, Yann; Kaladji, Adrien

    2018-02-01

    Flat-panel detectors on mobile C-arm (MC-arm) systems are currently challenging fixed C-arm (FC-arm) systems used in hybrid operating rooms. MC-arm systems offer an alternative to FC-arm systems in the endovascular treatment of peripheral arterial disease (PAD) but their efficiency has not been evaluated comparatively. Two series of patients undergoing arteriography with intention to treat were included. Each series consisted of 2 nonrandomized groups: an MC-arm group and an FC-arm group. Series 1 evaluated exposure to the patient (MC-arm, n = 113; FC-arm, n = 206) while series 2 evaluated exposure to patients and also health care personnel (MC-arm, n = 24; FC-arm, n = 76). The primary end points for evaluating exposure were air kerma (AK, in mGy) for patients and effective dose for health care personnel (in μSv). After adjustment for the effect of body mass index (analysis of covariance test), AK was found to be lower in the MC-arm group than in the FC-arm group (124.1 ± 142 vs. 173.3 ± 248.7, P = 0.025). There was no difference between the groups with regard to effective dose recorded for senior surgeons or for operating room nurses. However, a higher effective dose was recorded by the MC-arm group external dosimeter for the trainee resident and for nurse anesthetists. In endovascular treatment of lower limb PAD, use of an FC-arm system is associated with more radiation exposure to the patient than an MC-arm system. However, this type of imaging system does not appear to affect exposure to health care personnel. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Physical Analysis of Cross-Wedge Rolling Process of a Stepped Shaft

    Directory of Open Access Journals (Sweden)

    Łukasz Wójcik

    2017-12-01

    Full Text Available The paper presents experimental- model research results on the process of cross-wedge rolling of an axially-symmetrical element (stepped shaft. During research was used plastic mass on the basis of waxes in black and white colour. The aim of this experimental research was to determine the best option of forming in terms of values obtained and the course of forces. Physical examination was carried out using specialist machines, that is model and laboratory cross-wedge rolling mill. Experimental analysis was carried out using billets with the temperature of 15°C, whereas the actual process was carried out for billet from C45 carbon steel of temperature 1150°C. The study compared the dimensions of the components obtained during rolling tests and forming forces obtained in the result of physical modeling with forces obtained during real tests.

  5. Generation of vector beams using a double-wedge depolarizer: Non-quantum entanglement

    Science.gov (United States)

    Samlan, C. T.; Viswanathan, Nirmal K.

    2016-07-01

    Propagation of horizontally polarized Gaussian beam through a double-wedge depolarizer generates vector beams with spatially varying state of polarization. Jones calculus is used to show that such beams are maximally nonseparable on the basis of even (Gaussian)-odd (Hermite-Gaussian) mode parity and horizontal-vertical polarization state. The maximum nonseparability in the two degrees of freedom of the vector beam at the double wedge depolarizer output is verified experimentally using a modified Sagnac interferometer and linear analyser projected interferograms to measure the concurrence 0.94±0.002 and violation of Clauser-Horne-Shimony-Holt form of Bell-like inequality 2.704±0.024. The investigation is carried out in the context of the use of vector beams for metrological applications.

  6. [A Patient with a Wedge-shaped Pulmonary Lesion Associated with Streptococcus parasanguinis].

    Science.gov (United States)

    Miyamoto, Hiroya; Gomi, Harumi; Ishioka, Haruhiko; Shirokawa, Taijiro

    2016-05-01

    An 84-year-old man was admitted to our hospital with bloody sputum. He was found to have a right lower lobe wedge-shaped nodular lesion with chest X-ray and computed tomography of the chest. Ceftriaxone and minocycline were started empirically based on a working diagnosis of community-acquired pneumonia. Streptococcus parasanguinis was isolated with sputum cultures obtained on three consecutive days and was identified based on its biochemical properties. S. parasanguinis is a member of the sanguinis group of viridans Streptococci. It is known as a causative pathogen for endocarditis. There are very few reports of S. parasanguinis associated with pulmonary infections. The present report describes the association of S. parasanguinis with a wedge-shaped nodular lesion in the lungs.

  7. Early weight bearing versus delayed weight bearing in medial opening wedge high tibial osteotomy: a randomized controlled trial.

    Science.gov (United States)

    Lansdaal, Joris Radboud; Mouton, Tanguy; Wascher, Daniel Charles; Demey, Guillaume; Lustig, Sebastien; Neyret, Philippe; Servien, Elvire

    2017-12-01

    The need for a period of non-weight bearing after medial opening wedge high tibial osteotomy remains controversial. It is hypothesized that immediate weight bearing after medial opening wedge high tibial osteotomy would have no difference in functional scores at one year compared to delayed weight bearing. Fifty patients, median age 54 years (range 40-65), with medial compartment osteoarthritis, underwent a medial opening wedge high tibial osteotomy utilizing a locking plate without bone grafting. Patients were randomized into an Immediate or a Delayed (2 months) weight bearing group. All patients were assessed at one-year follow-up and the two groups compared. The primary outcome measure was the IKS score. Secondary outcome measures included the IKDC score, the VAS pain score and rate of complications. The functional scores significantly improved in both groups. The IKS score increased from 142 ± 31 to 171 ± 26 in the Immediate group (p bearing after medial opening wedge high tibial osteotomy had no effect on functional scores at 1 year follow-up and did not significantly increase the complication rate. Immediate weight bearing after medial opening wedge high tibial osteotomy appears to be safe and can allow some patients a quicker return to activities of daily living and a decreased convalescence period. II.

  8. Spatial resolution of wedge shaped silicon microstrip detectors

    International Nuclear Information System (INIS)

    Anticic, T.; Barnett, B.; Blumenfeld, B.; Chien, C.Y.; Fisher, P.; Gougas, A.; Krizmanic, J.; Madansky, L.; Newman, D.; Orndorff, J.; Pevsner, A.; Spangler, J.

    1995-01-01

    Several wedge-shaped silicon microstrip detectors with pitches from 30 to 100 μm have been designed by our group and beam tested at the CERN SPS. We find the spatial resolution σ becomes larger at the rate of 0.21 μm per 1 μm increase in pitch, but the number of strips per cluster remains about the same as the pitch varies from 30 to 100 μm. (orig.)

  9. Estimating effective wedge factor for enhanced dynamic wedge 2100CD a Varian Clinac; Calculo De factor cuna efectiva para cuna dinamica mejorada de un Clinac 2100CD de Varian

    Energy Technology Data Exchange (ETDEWEB)

    Pizarro Trigo, F.; Morillas Ruiz, J.; Nunuz Martinez, L.; Sanchez Jimenez, J.

    2011-07-01

    The purpose of this paper is to compare different methods of calculating the effective factor enhanced dynamic wedge (EDWF) with the values ??obtained in measurements of symmetric and asymmetric fields.

  10. Seismological evidence for a sub-volcanic arc mantle wedge beneath the Denali volcanic gap, Alaska

    Science.gov (United States)

    McNamara, D.E.; Pasyanos, M.E.

    2002-01-01

    Arc volcanism in Alaska is strongly correlated with the 100 km depth contour of the western Aluetian Wadati-Benioff zone. Above the eastern portion of the Wadati-Benioff zone however, there is a distinct lack of volcanism (the Denali volcanic gap). We observe high Poisson's ratio values (0.29-0.33) over the entire length of the Alaskan subduction zone mantle wedge based on regional variations of Pn and Sn velocities. High Poisson's ratios at this depth (40-70 km), adjacent to the subducting slab, are attributed to melting of mantle-wedge peridotites, caused by fluids liberated from the subducting oceanic crust and sediments. Observations of high values of Poisson's ratio, beneath the Denali volcanic gap suggest that the mantle wedge contains melted material that is unable to reach the surface. We suggest that its inability to migrate through the overlying crust is due to increased compression in the crust at the northern apex of the curved Denali fault.

  11. WIDEFIELD SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY IMAGING OF PERIPHERAL ROUND RETINAL HOLES WITH OR WITHOUT RETINAL DETACHMENT.

    Science.gov (United States)

    Casswell, Edward J; Abou Ltaif, Sleiman; Carr, Thomas; Keane, Pearse A; Charteris, David G; Wickham, Louisa

    2018-03-02

    To describe the widefield spectral-domain optical coherence tomography features of peripheral round retinal holes, with or without associated retinal detachment (RD). Retrospective, observational study of 28 eyes with peripheral round retinal holes, with and without RD. Patients underwent imaging with a widefield 50-degree spectral-domain optical coherence tomography (Heidelberg Engineering, Germany) and Optos ultra-widefield imaging systems (Optos, United Kingdom). Vitreous attachment at the site of the retinal hole was detected in 27/28 (96.4%) cases. Cases were split into three groups: RHs with RD (n = 12); RHs with subretinal fluid (n = 5), and flat RHs (n = 11), with minimal or no subretinal fluid. 91.6% retinal holes associated with subretinal fluid or RD had vitreous attachment at the site of the hole. Eighty percent had vitreous attachment at both edges of the retinal hole, in a U-shape configuration, which appeared to exert traction. By contrast, flat retinal holes had visible vitreous attachment only at one edge of the retinal hole in 45.4%. Vitreous attachment was commonly seen at the site of round retinal holes. Vitreous attachment at both edges of the retinal hole in a U-shape configuration was more commonly seen at holes associated with subretinal fluid or RD.

  12. The effect of shoe design and lateral wedges on knee load and neuromuscular control in healthy subjects during walking

    DEFF Research Database (Denmark)

    Mølgaard, Carsten Møller; Kersting, Uwe G.

    2013-01-01

    and second peak knee adduction moments. However, the variability of this moment between shoe designs was of similar magnitude as the effect of laterally wedged insoles. Only marginal changes in muscle activity for gastrocnemius when walking with the wedged Oxford shoe were revealed. Conclusion: Lateral...

  13. The optimal design of stepped wedge trials with equal allocation to sequences and a comparison to other trial designs.

    Science.gov (United States)

    Thompson, Jennifer A; Fielding, Katherine; Hargreaves, James; Copas, Andrew

    2017-12-01

    Background/Aims We sought to optimise the design of stepped wedge trials with an equal allocation of clusters to sequences and explored sample size comparisons with alternative trial designs. Methods We developed a new expression for the design effect for a stepped wedge trial, assuming that observations are equally correlated within clusters and an equal number of observations in each period between sequences switching to the intervention. We minimised the design effect with respect to (1) the fraction of observations before the first and after the final sequence switches (the periods with all clusters in the control or intervention condition, respectively) and (2) the number of sequences. We compared the design effect of this optimised stepped wedge trial to the design effects of a parallel cluster-randomised trial, a cluster-randomised trial with baseline observations, and a hybrid trial design (a mixture of cluster-randomised trial and stepped wedge trial) with the same total cluster size for all designs. Results We found that a stepped wedge trial with an equal allocation to sequences is optimised by obtaining all observations after the first sequence switches and before the final sequence switches to the intervention; this means that the first sequence remains in the control condition and the last sequence remains in the intervention condition for the duration of the trial. With this design, the optimal number of sequences is [Formula: see text], where [Formula: see text] is the cluster-mean correlation, [Formula: see text] is the intracluster correlation coefficient, and m is the total cluster size. The optimal number of sequences is small when the intracluster correlation coefficient and cluster size are small and large when the intracluster correlation coefficient or cluster size is large. A cluster-randomised trial remains more efficient than the optimised stepped wedge trial when the intracluster correlation coefficient or cluster size is small. A

  14. Long-range Rocky Flats utilization study

    International Nuclear Information System (INIS)

    1983-02-01

    The purpose of this Study was to provide information concerning the Rocky Flats Plant and its operations that will be useful to the Nation's decision-makers in determining the long-range future of the Plant. This Study was conducted under the premise that national defense policy must be supported and, accordingly, the capabilities at Rocky Flats must be maintained there or at some other location(s). The Study, therefore, makes no attempt to speculate on how possible future changes in national defense policy might affect decisions regarding the utilization of Rocky Flats. Factors pertinent to decisions regarding Rocky Flats, which are included in the Study, are: physical condition of the Plant and its vulnerabilities to natural phenomena; risks associated with plutonium to Plant workers and the public posed by postulated natural phenomena and operational accidents; identification of alternative actions regarding the future use of the Rocky Flats Plant with associated costs and time scales; local socioeconomic impacts if Rocky Flats operations were relocated; and potential for other uses if Rocky Flats facilities were vacated. The results of the tasks performed in support of this Study are summarized in the context of these five factors

  15. Comparison between dose calculation in XiO® and dosimetric measurements in virtual wedge photon beams

    International Nuclear Information System (INIS)

    Almeida, Laila G.; Amaral, Leonardo L.; Oliveira, Harley F.; Maia, Ana F.

    2012-01-01

    The virtual wedge is useful tool in the radiation treatment planning since it has series of advantages over the hard wedge. Quality control tests ensure correct performance of the planning done in treatment planning systems (TPS). This study aimed to compare doses calculated by TPS and doses measured by ionization chamber (CI) and an ionization chambers array in virtual wedge photon beams of 6 MV. Measures carried out in Primus linear accelerator with a solid water phantom and dosimeter positioned at 10 cm depth with gantry at 0° in many fields sizes and angles in the virtual wedge. Measurements on the central axis used as dosimeter an IC and on off-axis used an IC array. The simulation in CMS-XiO used the CT images of the phantom in the same configuration of the irradiation. Maximum and minimum values of the percentage differences between the doses provided by TPS and measurements with ionization chamber on the central axis were 1.43 and -0.10%, respectively, with average percentage difference of 0.08% and confidence limit of Δ=1.72%. In the region off-axis, the average percentage difference was 0.04%, with a maximum of 1.9%, minimum of 0% and confidence limit of Δ=1.91%. All values for dose percentage differences were below 2% and lower confidence limit of 3% are thus, according to the recommendations of the Technical Report Series - TRS-430. (author)

  16. Dosimetry of normal and wedge fields for a cobalt-60 teletherapy unit

    International Nuclear Information System (INIS)

    Tripathi, U.B.; Kelkar, N.Y.

    1980-01-01

    A simple analytical method for computation of dose distributions for normal and wedge fields is described and the use of the method in planning radiation treatment is outlined. Formulas has been given to compute: (1) depth dose along central axis of cobalt-60 beam, (2) dose to off-axis points, and (3) dose distribution for a wedge field. Good agreement has been found between theoretical and experimental values. With the help of these formulae, the dose at any point can be easily and accurately calculated and radiotherapy can be planned for tumours of very odd shape and sizes. The limitation of the method is that the formulae have been derived for 50% field definition. For cobalt-60 machine having any other field definition, appropriate correction factors have to be applied. (M.G.B.)

  17. Surgeons’ Volume-Outcome Relationship for Lobectomies and Wedge Resections for Cancer Using Video-Assisted Thoracoscopic Techniques

    Directory of Open Access Journals (Sweden)

    Guy David

    2012-01-01

    Full Text Available This study examined the effect of surgeons’ volume on outcomes in lung surgery: lobectomies and wedge resections. Additionally, the effect of video-assisted thoracoscopic surgery (VATS on cost, utilization, and adverse events was analyzed. The Premier Hospital Database was the data source for this analysis. Eligible patients were those of any age undergoing lobectomy or wedge resection using VATS for cancer treatment. Volume was represented by the aggregate experience level of the surgeon in a six-month window before each surgery. A positive volume-outcome relationship was found with some notable features. The relationship is stronger for cost and utilization outcomes than for adverse events; for thoracic surgeons as opposed to other surgeons; for VATS lobectomies rather than VATS wedge resections. While there was a reduction in cost and resource utilization with greater experience in VATS, these outcomes were not associated with greater experience in open procedures.

  18. Stress Analysis and Model Test of Rock Breaking by Arc Blade Wedged Hob

    Directory of Open Access Journals (Sweden)

    Ying-chao Liu

    2016-07-01

    Full Text Available Based on rock compression-shear damage theory, the mechanical characteristics of an arc blade wedged hob were analyzed to study the rock fragmentation mechanism of hob during excavation, and rock fragmentation forecasting model of the arc blade wedged hob was improved. A spoke type cutter model which is similar to the tunnel boring machine (TBM cutter head was designed to study the rock fragmentation efficiency in different cutter spacing by adjusting the bearing sleeve size to obtain different distances between the hobs. The results show that the hob-breaking rock force mainly comes from three directions. The vertical force along the direction of the tunnel excavation, which is associated with uniaxial compressive strength of rock mass, plays a key role in the process of rock fragmentation. Field project data shows that the prediction model’s results of rock fragmentation in this paper are closer to the measured results than the results of the traditional linear cutting model. The optimal cutter spacing exists among different cutter spacings to get higher rock fragmentation rate and lower energy consumption during rock fragmentation. It is of great reference significance to design the arc blade wedged hob and enhance the efficiency of rock fragmentation in rock strata.

  19. Percutaneous dorsal closing wedge osteotomy of the metatarsal neck in management of metatarsalgia.

    Science.gov (United States)

    Lui, Tun Hing

    2014-12-01

    Metatarsalgia can be caused by plantarflexion of a central metatarsal or discrepancies in the metatarsals' length. Nonsurgical management is usually sufficient to achieve satisfactory results. For those recalcitrant cases, metatarsal osteotomy is needed to relieve the pain. We describe a technique of percutaneous dorsal closing wedge osteotomy of the metatarsal to manage the recalcitrant metatarsalgia. A case series was reviewed retrospectively. From March 2010 to March 2013, percutaneous dorsal closing wedge osteotomy of the metatarsal neck has been performed in 33 patients. Thirty six feet with 63 metatarsals were operated on. Thirty two second metatarsals, 22 third metatarsals, 5 fourth metatarsals and 4 fifth metatarsals were operated on. All the osteotomy sites healed up without any transverse plane deformity. The painful callosities subsided except in one operated metatarsal. Recurrence of painful callosities occurred in 2 operated metatarsals. Transfer metatarsalgia occurred in 2 feet. Floating toe deformity occurred in 2 operated rays. There was no nerve injury noted. Two patients had delayed wound healing with serous discharge and the wounds were eventually healed up with wound dressing. Percutaneous dorsal closing wedge osteotomy of the metatarsal neck is an effective and safe surgical treatment of recalcitrant metatarsalgia. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Altering Knee Abduction Angular Impulse Using Wedged Insoles for Treatment of Patellofemoral Pain in Runners: A Six-Week Randomized Controlled Trial.

    Directory of Open Access Journals (Sweden)

    Ryan T Lewinson

    Full Text Available Determine if a change in internal knee abduction angular impulse (KAAI is related to pain reduction for runners with patellofemoral pain (PFP by comparing lateral and medial wedge insole interventions, and increased KAAI and decreased KAAI groups.Randomized controlled clinical trial (ClinicalTrials.gov ID# NCT01332110.Biomechanics laboratory and community.Thirty-six runners with physician-diagnosed PFP enrolled in the trial, and 27 were analyzed.Runners with PFP were randomly assigned to either an experimental 3 mm lateral wedge or control 6 mm medial wedge group. Participants completed a biomechanical gait analysis to quantify KAAIs with their assigned insole, and then used their assigned insole for six-weeks during their regular runs. Usual pain during running was measured at baseline and at six-week follow-up using a visual analog scale. Statistical tests were performed to identify differences between wedge types, differences between biomechanical response types (i.e. increase or decrease KAAI, as well as predictors of pain reduction.Percent change in KAAI relative to neutral, and % change in pain over six weeks.Clinically meaningful reductions in pain (>33% were measured for both footwear groups; however, no significant differences between footwear groups were found (p = 0.697. When participants were regrouped based on KAAI change (i.e., increase or decrease, again, no significant differences in pain reduction were noted (p = 0.146. Interestingly, when evaluating absolute change in KAAI, a significant relationship between absolute % change in KAAI and % pain reduction was observed (R2 = 0.21; p = 0.030, after adjusting for baseline pain levels.The greater the absolute % change in KAAI during running, the greater the % reduction in pain over six weeks, regardless of wedge type, and whether KAAIs increased or decreased. Lateral and medial wedge insoles were similar in effectiveness for treatment of PFP.Altering KAAI should be a focus of future

  1. The Hardy inequality and the heat flow in curved wedges

    Czech Academy of Sciences Publication Activity Database

    Krejčiřík, David

    2016-01-01

    Roč. 73, č. 2 (2016), s. 91-113 ISSN 0032-5155 R&D Projects: GA ČR(CZ) GA14-06818S Institutional support: RVO:61389005 Keywords : Hardy inequality * heat equation * large-time behaviour * curved wedges * Dirichlet Laplacian * conical singularities * Brownian motion * subcriticality Subject RIV: BE - Theoretical Physics Impact factor: 0.735, year: 2016

  2. Trajectory Optimization for Differential Flat Systems

    OpenAIRE

    Kahina Louadj; Benjamas Panomruttanarug; Alexandre Carlos Brandao Ramos; Felix Mora-Camino

    2016-01-01

    International audience; The purpose of this communication is to investigate the applicability of Variational Calculus to the optimization of the operation of differentially flat systems. After introducingcharacteristic properties of differentially flat systems, the applicability of variational calculus to the optimization of flat output trajectories is displayed. Two illustrative examples are also presented.

  3. Can field-in-field technique replace wedge filter in radiotherapy treatment planning: a comparative analysis in various treatment sites

    International Nuclear Information System (INIS)

    Prabhakar, R.; Julka, P.K.; Rath, G.K.

    2008-01-01

    The aim of the study was to show whether field-in-field (FIF) technique can be used to replace wedge filter in radiation treatment planning. The study was performed in cases where wedges are commonly used in radiotherapy treatment planning. Thirty patients with different malignancies who received radiotherapy were studied. This includes patients with malignancies of brain, head and neck, breast, upper and lower abdomen. All the patients underwent computed tomography scanning and the datasets were transferred to the treatment planning system. Initially, wedge based planning was performed to achieve the best possible dose distribution inside the target volume with multileaf collimators (Plan1). Wedges were removed from a copy of the same plan and FIF plan was generated (Plan2). The two plans were then evaluated and compared for mean dose, maximum dose, median dose, doses to 2% (D 2 ) and 98% (D 9 8) of the target volume, volume receiving greater than 107% of the prescribed dose (V>107%), volume receiving less than 95% of the prescribed dose (V 2 , V>107% and CI for more of the sites with statistically significant reduction in monitor units. FIF results in better dose distribution in terms of homogeneity in most of the sites. It is feasible to replace wedge filter with FIF in radiotherapy treatment planning.

  4. Rocky Flats Compliance Program

    International Nuclear Information System (INIS)

    1994-02-01

    The Department of Energy (DOE) established the Office of Technology Development (EM-50) (OTD) as an element of Environmental Restoration and Waste Management (EM) in November 1989. The primary objective of the Office of Technology Development, Rocky Flats Compliance Program (RFCP), is to develop altemative treatment technologies for mixed low-level waste (wastes containing both hazardous and radioactive components) to use in bringing the Rocky Flats Plant (RFP) into compliance with Federal and state regulations and agreements. Approximately 48,000 cubic feet of untreated low-level mixed waste, for which treatment has not been specified, are stored at the RFP. The cleanup of the Rocky Flats site is driven by agreements between DOE, the Environmental Protection Agency (EPA), and the Colorado Department of Health (CDH). Under these agreements, a Comprehensive Treatment and Management Plan (CTMP) was drafted to outline the mechanisms by which RFP will achieve compliance with the regulations and agreements. This document describes DOE's strategy to treat low-level mixed waste to meet Land Disposal Restrictions and sets specific milestones related to the regulatory aspects of technology development. These milestones detail schedules for the development of technologies to treat all of the mixed wastes at the RFP. Under the Federal Facilities Compliance Act (FFCA), the CTMP has been incorporated into Rocky Flats Plant Conceptual Site Treatment Plan (CSTP). The CSTP will become the Rocky Flats Plant site Treatment Plan in 1995 and will supersede the CTMP

  5. 49 CFR 231.6 - Flat cars.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Flat cars. 231.6 Section 231.6 Transportation... TRANSPORTATION RAILROAD SAFETY APPLIANCE STANDARDS § 231.6 Flat cars. (Cars with sides 12 inches or less above the floor may be equipped the same as flat cars.) (a) Hand brakes—(1) Number. Same as specified for...

  6. Exact Riemann solutions of the Ripa model for flat and non-flat bottom topographies

    Science.gov (United States)

    Rehman, Asad; Ali, Ishtiaq; Qamar, Shamsul

    2018-03-01

    This article is concerned with the derivation of exact Riemann solutions for Ripa model considering flat and non-flat bottom topographies. The Ripa model is a system of shallow water equations accounting for horizontal temperature gradients. In the case of non-flat bottom topography, the mass, momentum and energy conservation principles are utilized to relate the left and right states across the step-type bottom topography. The resulting system of algebraic equations is solved iteratively. Different numerical case studies of physical interest are considered. The solutions obtained from developed exact Riemann solvers are compared with the approximate solutions of central upwind scheme.

  7. Analysis of Ventilation Regimes of the Oblique Wedge-Shaped Surface Piercing Hydrofoil During Initial Water Entry Process

    Directory of Open Access Journals (Sweden)

    Ghadimi Parviz

    2018-03-01

    Full Text Available The suction side of a surface piercing hydrofoil, as a section of a Surface Piercing Propeller (SPP, is usually exposed to three phases of flow consisting air, water, and vapour. Hence, ventilation and cavitation pattern of such section during the initial phase of water entry plays an essential role for the propeller’s operational curves. Accordingly, in the current paper a numerical simulation of a simple surface piercing hydrofoil in the form of an oblique wedge is conducted in three-phase environment by using the coupled URANS and VOF equations. The obtained results are validated against water entry experiments and super-cavitation tunnel test data. The resulting pressure curves and free surface profiles of the wedge water entry are presented for different velocity ratios ranging from 0.12 to 0.64. Non-dimensional forces and efficiency relations are defined in order to present the wedge water entry characteristics. Congruent patterns are observed between the performance curves of the propeller and the wedge in different fully ventilated or partially cavitated operation modes. The transition trend from fully ventilated to partially cavitated operation of the surface piercing section of a SPP is studied and analyzed through wedge’s performance during the transitional period.

  8. Forearc Basin Stratigraphy and Interactions With Accretionary Wedge Growth According to the Critical Taper Concept

    Science.gov (United States)

    Noda, Atsushi

    2018-03-01

    Forearc basins are important constituents of sediment traps along subduction zones; the basin stratigraphy records various events that the basin experienced. Although the linkage between basin formation and accretionary wedge growth suggests that mass balance exerts a key control on their evolution, the interaction processes between basin and basement remain poorly understood. This study performed 2-D numerical simulations in which basin stratigraphy was controlled by changes in sediment fluxes with accretionary wedge growth according to the critical taper concept. The resultant stratigraphy depended on the degree of filling (i.e., whether the basin was underfilled or overfilled) and the volume balance between the sediment flux supplied to the basin from the hinterland and the accommodation space in the basin. The trenchward progradation of deposition with onlapping contacts on the trenchside basin floor occurred during the underfilled phase, which formed a wedge-shaped sedimentary unit. In contrast, the landward migration of the depocenter, with the tilting of strata, was characteristic for the overfilled phase. Condensed sections marked stratigraphic boundaries, indicating when sediment supply or accommodation space was limited. The accommodation-limited intervals could have formed during the end of wedge uplift or when the taper angle decreased and possibly associated with the development of submarine canyons as conduits for bypassing sediments from the hinterland. Variations in sediment fluxes and their balance exerted a strong influence on the stratigraphic patterns in forearc basins. Assessing basin stratigraphy could be a key to evaluating how subduction zones evolve through their interactions with changing surface processes.

  9. Changes in patellofemoral alignment do not cause clinical impact after open-wedge high tibial osteotomy.

    Science.gov (United States)

    Lee, Yong Seuk; Lee, Sang Bok; Oh, Won Seok; Kwon, Yong Eok; Lee, Beom Koo

    2016-01-01

    The objectives of this study were (1) to evaluate the clinical and radiologic outcomes of open-wedge high tibial osteotomy focusing on patellofemoral alignment and (2) to search for correlation between variables and patellofemoral malalignment. A total of 46 knees (46 patients) from 32 females and 14 males who underwent open-wedge high tibial osteotomy were included in this retrospective case series. Outcomes were evaluated using clinical scales and radiologic parameters at the last follow-up. Pre-operative and final follow-up values were compared for the outcome analysis. For the focused analysis of the patellofemoral joint, correlation analyses between patellofemoral variables and pre- and post-operative weight-bearing line (WBL), clinical score, posterior slope, Blackburn Peel ratio, lateral patellar tilt, lateral patellar shift, and congruence angle were performed. The minimum follow-up period was 2 years and median follow-up period was 44 months (range 24-88 months). The percentage of weight-bearing line was shifted from 17.2 ± 11.1 to 56.7 ± 12.7%, and it was statistically significant (p patellofemoral malalignment, the pre-operative weight-bearing line showed an association with the change in lateral patellar tilt and lateral patellar shift (correlation coefficient: 0.3). After open-wedge high tibial osteotomy, clinical results showed improvement, compared to pre-operative values. The patellar tilt and lateral patellar shift were not changed; however, descent of the patella was observed. Therefore, mild patellofemoral problems should not be a contraindication of the open-wedge high tibial osteotomy. Case series, Level IV.

  10. Inadequacy of ethical conduct and reporting of stepped wedge cluster randomized trials: Results from a systematic review.

    Science.gov (United States)

    Taljaard, Monica; Hemming, Karla; Shah, Lena; Giraudeau, Bruno; Grimshaw, Jeremy M; Weijer, Charles

    2017-08-01

    Background/aims The use of the stepped wedge cluster randomized design is rapidly increasing. This design is commonly used to evaluate health policy and service delivery interventions. Stepped wedge cluster randomized trials have unique characteristics that complicate their ethical interpretation. The 2012 Ottawa Statement provides comprehensive guidance on the ethical design and conduct of cluster randomized trials, and the 2010 CONSORT extension for cluster randomized trials provides guidelines for reporting. Our aims were to assess the adequacy of the ethical conduct and reporting of stepped wedge trials to date, focusing on research ethics review and informed consent. Methods We conducted a systematic review of stepped wedge cluster randomized trials in health research published up to 2014 in English language journals. We extracted details of study intervention and data collection procedures, as well as reporting of research ethics review and informed consent. Two reviewers independently extracted data from each trial; discrepancies were resolved through discussion. We identified the presence of any research participants at the cluster level and the individual level. We assessed ethical conduct by tabulating reporting of research ethics review and informed consent against the presence of research participants. Results Of 32 identified stepped wedge trials, only 24 (75%) reported review by a research ethics committee, and only 16 (50%) reported informed consent from any research participants-yet, all trials included research participants at some level. In the subgroup of 20 trials with research participants at cluster level, only 4 (20%) reported informed consent from such participants; in 26 trials with individual-level research participants, only 15 (58%) reported their informed consent. Interventions (regardless of whether targeting cluster- or individual-level participants) were delivered at the group level in more than two-thirds of trials; nine trials (28

  11. Arc-parallel extension and fluid flow in an ancient accretionary wedge: The San Juan Islands, Washington

    Science.gov (United States)

    Schermer, Elizabeth R.; Gillaspy, J.R.; Lamb, R.

    2007-01-01

    Structural analysis of the Lopez Structural Complex, a major Late Cretaceous terrane-bounding fault zone in the San Juan thrust system, reveals a sequence of events that provides insight into accretionary wedge mechanics and regional tectonics. After formation of regional ductile flattening and shear-related fabrics, the area was crosscut by brittle structures including: (1) southwest-vergent thrusts, (2) extension veins and normal faults related to northwest-southeast extension, and (3) conjugate strike-slip structures that record northwest-southeast extension and northeast-southwest shortening. Aragonite-bearing veins are associated with thrust and normal faults, but only rarely with strike-slip faults. High-pressure, low-temperature (HP-LT) minerals constrain the conditions for brittle deformation to ???20 km and formed in an accretionary prism during active subduction, which suggests that these brittle structures record internal wedge deformation at depth and early during uplift of the San Juan nappes. The structures are consistent with orogen-normal shortening and vertical thickening followed by vertical thinning and along-strike extension. The kinematic evolution may be related initially to changes in wedge strength, followed by response to overthickening of the wedge in an unbuttressed, obliquely convergent setting. The change in vein mineralogy indicates that exhumation occurred prior to the strike-slip event. The pressure and temperature conditions and spatial and temporal extent of small faults associated with fluid flow suggest a link between these structures and the silent earthquake process. ?? 2007 Geological Society of America.

  12. Interpretation and inverse analysis of the wedge splitting test

    DEFF Research Database (Denmark)

    Østergaard, Lennart; Stang, Henrik

    2002-01-01

    to the wedge splitting test and that it is well suited for the interpretation of test results in terms of s(w). A fine agreement between the hinge and FEM-models has been found. It has also been found that the test and the hinge model form a solid basis for inverse analysis. The paper also discusses possible...... three dimensional problems in the experiment as well as the influence of specimen size....

  13. Exact piecewise flat gravitational waves

    NARCIS (Netherlands)

    van de Meent, M.

    2011-01-01

    We generalize our previous linear result (van de Meent 2011 Class. Quantum Grav 28 075005) in obtaining gravitational waves from our piecewise flat model for gravity in 3+1 dimensions to exact piecewise flat configurations describing exact planar gravitational waves. We show explicitly how to

  14. Laser Oscillator Incorporating a Wedged Polarization Rotator and a Porro Prism as Cavity Mirror

    Science.gov (United States)

    Li, Steven

    2011-01-01

    A laser cavity was designed and implemented by using a wedged polarization rotator and a Porro prism in order to reduce the parts count, and to improve the laser reliability. In this invention, a z-cut quartz polarization rotator is used to compensate the wavelength retardance introduced by the Porro prism. The polarization rotator rotates the polarization of the linear polarized beam with a designed angle that is independent of the orientation of the rotator. This unique property was used to combine the retardance compensation and a Risley prism to a single optical component: a wedged polarization rotator. This greatly simplifies the laser alignment procedure and reduces the number of the laser optical components.

  15. Fabrication of customizable wedged multilayer Laue lenses by adding a stress layer

    International Nuclear Information System (INIS)

    Niese, Sven; Krüger, Peter; Kubec, Adam; Laas, Roman; Gawlitza, Peter; Melzer, Kathleen; Braun, Stefan; Zschech, Ehrenfried

    2014-01-01

    Diffractive optics for hard X-rays feature superior properties in terms of resolution and efficiency, if volume diffraction effects are exploited all-over the aperture. For multilayer Laue lenses, preferably a wedged geometry is required to obtain this effect. We present an approach utilizing an additional stress layer to realize the necessary geometrical modifications where each lens can be customized to a selected photon energy independently of the given multilayer deposition. The quality of the deposition of the stress layer is evaluated using a laboratory X-ray microscope prior to its application at synchrotron radiation facilities with a special approach to measure the relative layer tilt at high spatial resolution. - Highlights: • Wedged multilayer Laue lenses were fabricated using an additional stress layer. • Each lens can be customized to any photon energy independently of the multilayer. • The relative layer tilt is measured using laboratory X-ray microscopy

  16. Rigidity of generalized Bach-flat vacuum static spaces

    Science.gov (United States)

    Yun, Gabjin; Hwang, Seungsu

    2017-11-01

    In this paper, we study the structure of generalized Bach-flat vacuum static spaces. Generalized Bach-flat metrics are considered as extensions of both Einstein and Bach-flat metrics. First, we prove that a compact Riemannian n-manifold with n ≥ 4 which is a generalized Bach-flat vacuum static space is Einstein. A generalized Bach-flat vacuum static space with the potential function f having compact level sets is either Ricci-flat or a warped product with zero scalar curvature when n ≥ 5, and when n = 4, it is Einstein if f has its minimum. Secondly, we consider critical metrics for another quadratic curvature functional involving the Ricci tensor, and prove similar results. Lastly, by applying the technique developed above, we prove Besse conjecture when the manifold is generalized Bach-flat.

  17. Heat conduction problem of an evaporating liquid wedge

    Directory of Open Access Journals (Sweden)

    Tomas Barta

    2015-02-01

    Full Text Available We consider the stationary heat transfer near the contact line of an evaporating liquid wedge surrounded by the atmosphere of its pure vapor. In a simplified setting, the problem reduces to the Laplace equation in a half circle, subject to a non-homogeneous and singular boundary condition. By classical tools (conformal mapping, Green's function, we reformulate the problem as an integral equation for the unknown Neumann boundary condition in the setting of appropriate fractional Sobolev and weighted space. The unique solvability is then obtained by means of the Fredholm theorem.

  18. Polymer gel measurement of dose homogeneity in the breast: comparing MLC intensity modulation with standard wedged delivery

    International Nuclear Information System (INIS)

    Love, P A; Evans, P M; Leach, M O; Webb, S

    2003-01-01

    Polymer gel dosimetry has been used to measure the radiotherapy dose homogeneity in a breast phantom for two different treatment methods. The first 'standard' method uses two tangential wedged fields while the second method has three static fields shaped by multileaf collimators (MLCs) in addition to the standard wedged fields to create intensity modulated fields. Gel dose distributions from the multileaf modulation treatment show an improved dose uniformity in comparison to the standard treatment with a decreased volume receiving doses over 105%

  19. Effects of Added Mass and Structural Damping on Dynamic Responses of a 3D Wedge Impacting on Water

    Directory of Open Access Journals (Sweden)

    Pengyao Yu

    2018-05-01

    Full Text Available The impact between the wave and the bottom of a high-speed vessel is often simplified as water-entry problems of wedges. Most investigations focus on the water entry of two dimensional (2D wedges. The effects of added mass and structural damping are still not fully investigated. By combining the normal mode method, the hydrodynamic impact model of rigid wedges and the potential flow theory, a dynamic model for predicting the response of a three dimensional (3D wedge impacting on water with a constant velocity is established in this paper. The present model can selectively consider the effects of the added mass and the structural damping. The present method has been validated through comparisons with results of published literatures and commercial software. It is found that the added mass can increase the stress response before the flow separation, and reduce the vibration frequency after the flow separation. Due to the effect of the added mass, the stress response of some positions after the flow separation is even higher than that before the flow separation. The structural damping has a negligible effect on the stress before the flow separation, but it can reduce vibration stress after the flow separation.

  20. Individual energy savings for individual flats in blocks of flats

    DEFF Research Database (Denmark)

    Nielsen, Anker; Rose, Jørgen

    2014-01-01

    and 1980. Normally, we expect the reduction in energy consumption to be around 20% for a 2 °C lower temperature, but for an inner flat the reduction can be up to 71%. The owners of the adjoining flats get an increase in energy demand of 10 to 20% each. They will not be able to figure out whether...... this is because the neighbour maintains a low temperature or the fact that they maintain a higher temperature. The best solution is to keep your own indoor temperature low. We can also turn the problem around: if you maintain a higher temperature than your neighbours, then you will pay part of their heating bill....

  1. Dissolved organic carbon loss from Yedoma permafrost amplified by ice wedge thaw

    NARCIS (Netherlands)

    Vonk, J.E.; Mann, P.J.; Dowdy, K.L.; Davydova, A.; Davydov, S.P.; Zimov, N.; Spencer, R.G.M.; Bulygina, E.B.; Eglinton, T.I.; Holmes, R.M.

    2013-01-01

    Pleistocene Yedoma permafrost contains nearly a third of all organic matter (OM) stored in circum-arctic permafrost and is characterized by the presence of massive ice wedges. Due to its rapid formation by sediment accumulation and subsequent frozen storage, Yedoma OM is relatively well preserved

  2. Restraint of fatigue crack growth by wedge effects of fine particles

    CERN Document Server

    Takahashi, I; Kotani, N

    2000-01-01

    Presents some experimental results which demonstrate restraint of fatigue crack growth in an Al-Mg alloy by wedge effects of fine particles. Fatigue test specimens were machined from a JIS A5083P-O Al-Mg alloy plate of 5 mm thickness and an EDM starter notch was introduced to each specimen. Three kinds of fine particles were prepared as the materials to be wedged into the fatigue cracks, i.e. magnetic particles and two kinds of alumina particles having different mean particle sizes of 47.3 mu m and 15.2 mu m. Particles of each kind were suspended in an oil to form a paste, which was applied on the specimen surface covering the notch zone prior to the fatigue tests. In order to make some fracture mechanics approaches, in situ observations of fatigue cracks were performed for the two cases using a CCD microscope, with a magnification of *1000. The crack length and the crack opening displacement (COD) at the notch root, delta , were measured. The crack retardation effect continues almost through the entire lifet...

  3. Pre-clinical test of the virtual wedge option of a PRIMUS linear accelerator and verification of the calculation algorithm in the treatment planning system HEAX-TMS

    International Nuclear Information System (INIS)

    Gesheva-Atanassova, N.; Balabanova, A.

    2006-01-01

    Full text: The purpose of the study is to check the long-time stability of the wedge angle and the wedge factor (WF) of Virtual Wedges for 6 and 18 MV photon beams, and the accuracy of the TPS HELAX-TMS, in order to accept the virtual wedge technique for patient treatment. All measurements - dose profiles, central axis dose distributions and applied dose for pre-calculated monitor units, have been performed in water, applying a calibrated 0.3 cm 3 ion chamber, 47 ion chamber array LA48 and the beam analyzing system MP3. The measured data has been compared with the corresponding planned data. During a four years time period the long time stability checking revealed no changes in the central axis distributions and variations of the wedge angles are within ± 2 deg. The values of WFs and the differences between calculated and measured dose values are in the acceptable limits, except for the 6 MV beam with wedge angle 60 deg and field size 20x20 cm 2 , where the deviation reaches 6.5%. The dose profile for depth up to 10 cm showed a good coincidence. Non acceptable deviations have been found for beam profiles at depth 20 cm and field size 20x20 cm 2 for both 6 and 18 MV. The Virtual Wedge Option of PRIMUS in combination with HELAX-TMS can be applied with confidence for radiotherapy with wedged beams except for the combination of field 20x20 cm 2 and angle 60 deg

  4. Optical necklaces generated by the diffraction on a stack of dielectric wedges

    Energy Technology Data Exchange (ETDEWEB)

    Izdebskaya, Yana [Nonlinear Physics Centre, Research School of Physical Sciences and Engineering, Australian National University, Canberra ACT 0200 (Australia); Department of Physics, V.I. Vernandsky Taurida National University, Simferopol 95007, Crimea (Ukraine)], E-mail: yvi124@rsphysse.anu.edu.au

    2008-05-19

    We demonstrate that the regular ring-shaped arrays of Gaussian beams, or optical necklaces, can be generated using diffraction on a stack of dielectric wedges. A condition for self-similarity and structural stability of the beams has been derived and shows good comparison with experimental data.

  5. A non-deltaic clinoform wedge fed by multiple sources off São Sebastião Island, southeastern Brazilian Shelf

    Science.gov (United States)

    Vieira, Ivo; Lobo, Francisco José; Montoya-Montes, Isabel; Siegle, Eduardo; Passos, Jorge Luiz; De Mahiques, Michel Michaelovitch

    2018-02-01

    São Sebastião Island (SSI) marks the latitudinal boundary between two sedimentological and geochemical provinces in the São Paulo Bight, an arc-shaped sector of the southeastern Brazilian Shelf. The island is separated from the continent by the narrow, deep São Sebastião Channel (SSC). A relatively thick sediment wedge—the São Sebastião Wedge (SSW)—has been formed offshore SSI. This study explores the possible genetic and evolutionary mechanisms of the wedge, bearing in mind that clinoform wedges can form at considerable distances from major fluvial sources. For that, a marine geological database has been interpreted comprising high-resolution seismic data, a surficial sediment map and several sediment cores, from which radiocarbon dates were obtained and sedimentation rates deduced. A wave model was also applied to obtain the dominant wave directions. The SSW is a wedge-shaped deposit, and its internal structure presents three seismic units. The two lowest are wedge shaped and arranged in a backstepping pattern. The most recent unit is mostly aggradational and can be divided into three seismic subunits. Sedimentological data show that at least the most recent unit is composed of a mixture of sands and silts. Modeled wave conditions indicate a major influence from southerly waves that are able to remobilize shelf sediments and to create a bypass sediment zone until the foreset of the deposit is reached at the water depths where the SSW is found. Taken together, these data suggest that the SSW formed through contributions from different sediment sources, and should be regarded as an intermediate case of a non-deltaic clinoform wedge. Sand transport in the area involves wind-driven currents passing through the SSC and sediment remobilization by energetic southerly waves. Fine-grained sediment is derived mostly from the joint contributions of many minor catchments located north of the island, and this sediment is later transported southwestward by the

  6. Harmonic manifolds with minimal horospheres are flat

    Indian Academy of Sciences (India)

    Abstract. In this note we reprove the known theorem: Harmonic manifolds with minimal horospheres are flat. It turns out that our proof is simpler and more direct than the original one. We also reprove the theorem: Ricci flat harmonic manifolds are flat, which is generally affirmed by appealing to Cheeger–Gromov splitting ...

  7. Harmonic Manifolds with Minimal Horospheres are Flat

    Indian Academy of Sciences (India)

    In this note we reprove the known theorem: Harmonic manifolds with minimal horospheres are flat. It turns out that our proof is simpler and more direct than the original one. We also reprove the theorem: Ricci flat harmonic manifolds are flat, which is generally affirmed by appealing to Cheeger–Gromov splitting theorem.

  8. Geometrical determinations of IMRT photon pencil-beam path in radiotherapy wedges and limit divergence angle with the Anisotropic Analytic Algorithm (AAA

    Directory of Open Access Journals (Sweden)

    Francisco Casesnoves

    2014-08-01

    Full Text Available Purpose: Static wedge filters (WF are commonly used in radiation therapy, forward and/or inverse planning. We calculated the exact 2D/3D geometrical pathway of the photon-beam through the usual alloy WF, in order to get a better dose related to the beam intensity attenuation factor(s, after the beam has passed through the WF. The objective was to provide general formulation into the Anisotropic Analytical Algorithm (AAA model coordinates system (depending on collimator/wedge angles that also can be applied to other models. Additionally, second purpose of this study was to develop integral formulation for 3D wedge exponential factor with statistical approximations, with introduction for the limit angle/conformal wedge.Methods: The radiotherapy model used to develop this mathematical task is the classical superposition-convolution algorithm, AAA (developed by Ulmer and Harder. We worked with optimal geometrical approximations to make the computational IMRT calculations quicker/reduce the planning-system time. Analytic geometry/computational-techniques to carry out simulations (for standard wedges are detailed/developed sharply. Integral developments/integral-statistical approximations are explained. Beam-divergence limit Angle for optimal wedge filtration formulas is calculated/sketched, with geometrical approximations. Fundamental trigonometry is used for this purpose.Results: Extent simulation tables for WF of 15º, 30º, 45º, and 60º are shown with errors. As a result, it is possible to determine the best individual treatment dose distribution for each patient. We presented these basic simulations/numerical examples for standard manufacturing WF of straight sloping surface, to check the accuracy/errors of the calculations. Simulations results give low RMS/Relative Error values (formulated for WF of 15º, 30º, 45º, and 60º.Conclusion: We obtained a series of formulas of analytic geometry for WF that can be applied for any particular dose

  9. Novel Ordered Stepped-Wedge Cluster Trial Designs for Detecting Ebola Vaccine Efficacy Using a Spatially Structured Mathematical Model.

    Directory of Open Access Journals (Sweden)

    Ibrahim Diakite

    2016-08-01

    Full Text Available During the 2014 Ebola virus disease (EVD outbreak, policy-makers were confronted with difficult decisions on how best to test the efficacy of EVD vaccines. On one hand, many were reluctant to withhold a vaccine that might prevent a fatal disease from study participants randomized to a control arm. On the other, regulatory bodies called for rigorous placebo-controlled trials to permit direct measurement of vaccine efficacy prior to approval of the products. A stepped-wedge cluster study (SWCT was proposed as an alternative to a more traditional randomized controlled vaccine trial to address these concerns. Here, we propose novel "ordered stepped-wedge cluster trial" (OSWCT designs to further mitigate tradeoffs between ethical concerns, logistics, and statistical rigor.We constructed a spatially structured mathematical model of the EVD outbreak in Sierra Leone. We used the output of this model to simulate and compare a series of stepped-wedge cluster vaccine studies. Our model reproduced the observed order of first case occurrence within districts of Sierra Leone. Depending on the infection risk within the trial population and the trial start dates, the statistical power to detect a vaccine efficacy of 90% varied from 14% to 32% for standard SWCT, and from 67% to 91% for OSWCTs for an alpha error of 5%. The model's projection of first case occurrence was robust to changes in disease natural history parameters.Ordering clusters in a step-wedge trial based on the cluster's underlying risk of infection as predicted by a spatial model can increase the statistical power of a SWCT. In the event of another hemorrhagic fever outbreak, implementation of our proposed OSWCT designs could improve statistical power when a step-wedge study is desirable based on either ethical concerns or logistical constraints.

  10. Changes in dip and frictional properties of the basal detachment controlling orogenic wedge propagation and frontal collapse: The external central Betics case

    Science.gov (United States)

    Jimenez-Bonilla, A.; Torvela, T.; Balanyá, J. C.; Expósito, I.; Díaz-Azpiroz, M.

    2016-12-01

    Thin-skinned fold-and-thrust belts (FTBs) have been extensively studied through both field examples and modeling. The overall dynamics of FTBs are, therefore, well understood. One less understood aspect is the combined influence of across-strike changes in the detachment properties and the basement topography on the behavior of an orogenic wedge. In this paper, we use field data together with reflection seismic interpretation from the external zones of the central Betics FTB, southern Spain, to identify a significant increase in the wedge basal dip (a basement "threshold") coinciding with the pinch-out of a weak substrate. This induced both changes to the wedge geometry and to the basal friction, which in turn influenced the wedge dynamics. The changing dynamics led to a transient "stagnation" of the FTB propagation, topographic buildup, and subsequent collapse of the FTB front. This in turn fed an important Langhian depocenter made up of mass transport deposits. Coevally with the FTB propagation, extension took place both parallel and perpendicular to the orogenic trend. This case study illustrates how across-strike changes in wedge basal properties can control the detailed behavior of a developing FTB front, but questions remain regarding the time-space interaction and relative importance of the basal parameters.

  11. Open wedge high tibial osteotomy using three-dimensional printed models: Experimental analysis using porcine bone.

    Science.gov (United States)

    Kwun, Jun-Dae; Kim, Hee-June; Park, Jaeyoung; Park, Il-Hyung; Kyung, Hee-Soo

    2017-01-01

    The purpose of this study was to evaluate the usefulness of three-dimensional (3D) printed models for open wedge high tibial osteotomy (HTO) in porcine bone. Computed tomography (CT) images were obtained from 10 porcine knees and 3D imaging was planned using the 3D-Slicer program. The osteotomy line was drawn from the three centimeters below the medial tibial plateau to the proximal end of the fibular head. Then the osteotomy gap was opened until the mechanical axis line was 62.5% from the medial border along the width of the tibial plateau, maintaining the posterior tibial slope angle. The wedge-shaped 3D-printed model was designed with the measured angle and osteotomy section and was produced by the 3D printer. The open wedge HTO surgery was reproduced in porcine bone using the 3D-printed model and the osteotomy site was fixed with a plate. Accuracy of osteotomy and posterior tibial slope was evaluated after the osteotomy. The mean mechanical axis line on the tibial plateau was 61.8±1.5% from the medial tibia. There was no statistically significant difference (P=0.160). The planned and post-osteotomy correction wedge angles were 11.5±3.2° and 11.4±3.3°, and the posterior tibial slope angle was 11.2±2.2° pre-osteotomy and 11.4±2.5° post-osteotomy. There were no significant differences (P=0.854 and P=0.429, respectively). This study showed that good results could be obtained in high tibial osteotomy by using 3D printed models of porcine legs. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Transport processes in intertidal sand flats

    Science.gov (United States)

    Wu, Christy

    2010-05-01

    Methane rich sulfate depleted seeps are observed along the low water line of the intertidal sand flat Janssand in the Wadden Sea. It is unclear where in the flat the methane is formed, and how it is transported to the edge of the sand flat where the sulfidic water seeps out. Methane and sulfate distributions in pore water were determined along transects from low water line toward the central area of the sand flat. The resulting profiles showed a zone of methane-rich and sulfate-depleted pore water below 2 m sediment depth. Methane production and sulfate reduction are monitored over time for surface sediments collected from the upper flat and seeping area. Both activities were at 22 C twice as high as at 15 C. The rates in sediments from the central area were higher than in sediments from the methane seeps. Methanogenesis occurred in the presence of sulfate, and was not significantly accelerated when sulfate was depleted. The observations show a rapid anaerobic degradation of organic matter in the Janssand. The methane rich pore water is obviously transported with a unidirectional flow from the central area of the intertidal sand flat toward the low water line. This pore water flow is driven by the pressure head caused by elevation of the pore water relative to the sea surface at low tide (Billerbeck et al. 2006a). The high methane concentration at the low water line accumulates due to a continuous outflow of pore water at the seepage site that prevents penetration of electron acceptors such as oxygen and sulfate to reoxidize the reduced products of anaerobic degradation (de Beer et al. 2006). It is, however, not clear why no methane accumulates or sulfate is depleted in the upper 2 m of the flats.

  13. Fluxes and burial of particulate organic carbon along the Adriatic mud-wedge (Mediterranean Sea)

    Science.gov (United States)

    Tesi, T.; Langone, L.; Giani, M.; Ravaioli, M.; Miserocchi, S.

    2012-04-01

    Clinoform-shaped deposits are ubiquitous sedimentological bodies of modern continental margins, including both carbonate and silicoclastic platforms. They formed after the attainment of the modern sea level high-stand (mid-late Holocene) when river outlets and shoreline migrated landward. As clinoform-shape deposits are essential building blocks of the infill of sedimentary basins, they are sites of intense organic carbon (OC) deposition and account for a significant fraction of OC burial in the ocean during interglacial periods. In this study, we focused on sigmoid clinoforms that are generally associated with low-energy environments. In particular, we characterized the modern accumulation and burial of OC along the late-Holocene sigmoid in the Western Adriatic Sea (Mediterranean Sea). This sedimentary body consists of a mud wedge recognizable on seismic profiles as a progradational unit lying on top the maximum flooding surface that marks the time of maximum landward shift of the shoreline attained around 5.5 kyr cal BP. In the last two decades, several projects have investigated sediment dynamics and organic geochemistry along the Adriatic mud wedge (e.g., PRISMA, EURODELTA, EuroSTRATAFORM, PASTA, CIPE, VECTOR). All these studies increased our understanding of strata formation and organic matter cycling in this epicontinental margin. The overarching goal of this study was to combine the results gained during these projects with newly acquired data to assess fluxes to seabed and burial efficiency of organic carbon along the uppermost strata of the Adriatic mud-wedge. Our study benefited of an extensive number of radionuclide-based (Pb-210, and Cs-137) sediment accumulation rates and numerous biogeochemical data of surface sediments and sediment cores (organic carbon, total nitrogen, radiocarbon measurements, carbon stable isotopes, and biomarkers). In addition, because the accumulation of river-borne sediment may or may not be linked to a specific source, another

  14. Stratification and salt-wedge in the Seomjin river estuary under the idealized tidal influence

    Science.gov (United States)

    Hwang, Jin Hwan; Jang, Dongmin; Kim, Yong Hoon

    2017-12-01

    Advection, straining, and vertical mixing play primary roles in the process of estuarine stratification. Estuaries can be classified as salt-wedge, partially-mixed or well-mixed depending on the vertical density structure determined by the balancing of advection, mixing and straining. In particular, straining plays a major role in the stratification of the estuarine water body along the estuarine channel. Also, the behavior of a salt wedge with a halocline shape in a stratified channel can be controlled by the competition between straining and mixing induced by buoyancy from the riverine source and tidal forcing. The present study uses Finite Volume Coastal Ocean Model (FVCOM) to show that straining and vertical mixing play major roles in controlling along-channel flow and stratification structures in the Seomjin river estuary (SRE) under idealized conditions. The Potential Energy Anomaly (PEA) dynamic equation quantifies the governing processes thereby enabling the determination of the stratification type. By comparing terms in the equation, we examined how the relative strengths of straining and mixing alter the stratification types in the SRE due to changes in river discharge and the depth resulting from dredging activities. SRE under idealized tidal forcing tends to be partially-mixed based on an analysis of the balance between terms and the vertical structure of salinity, and the morphological and hydrological change in SRE results in the shift of stratification type. While the depth affects the mixing, the freshwater discharge mainly controls the straining, and the balance between mixing and straining determines the final state of the stratification in an estuarine channel. As a result, the development and location of a salt wedge along the channel in a partially mixed and highly stratified condition is also determined by the ratio of straining to mixing. Finally, our findings confirm that the contributions of mixing and straining can be assessed by using the

  15. Deep long-period earthquakes west of the volcanic arc in Oregon: evidence of serpentine dehydration in the fore-arc mantle wedge

    Science.gov (United States)

    Vidale, John E.; Schmidt, David A.; Malone, Stephen D.; Hotovec-Ellis, Alicia J.; Moran, Seth C.; Creager, Kenneth C.; Houston, Heidi

    2014-01-01

    Here we report on deep long-period earthquakes (DLPs) newly observed in four places in western Oregon. The DLPs are noteworthy for their location within the subduction fore arc: 40–80 km west of the volcanic arc, well above the slab, and near the Moho. These “offset DLPs” occur near the top of the inferred stagnant mantle wedge, which is likely to be serpentinized and cold. The lack of fore-arc DLPs elsewhere along the arc suggests that localized heating may be dehydrating the serpentinized mantle wedge at these latitudes and causing DLPs by dehydration embrittlement. Higher heat flow in this region could be introduced by anomalously hot mantle, associated with the western migration of volcanism across the High Lava Plains of eastern Oregon, entrained in the corner flow proximal to the mantle wedge. Alternatively, fluids rising from the subducting slab through the mantle wedge may be the source of offset DLPs. As far as we know, these are among the first DLPs to be observed in the fore arc of a subduction-zone system.

  16. Refinement of the wedge bar technique for compression tests at intermediate strain rates

    Directory of Open Access Journals (Sweden)

    Stander M.

    2012-08-01

    Full Text Available A refined development of the wedge-bar technique [1] for compression tests at intermediate strain rates is presented. The concept uses a wedge mechanism to compress small cylindrical specimens at strain rates in the order of 10s−1 to strains of up to 0.3. Co-linear elastic impact principles are used to accelerate the actuation mechanism from rest to test speed in under 300μs while maintaining near uniform strain rates for up to 30 ms, i.e. the transient phase of the test is less than 1% of the total test duration. In particular, a new load frame, load cell and sliding anvil designs are presented and shown to significantly reduce the noise generated during testing. Typical dynamic test results for a selection of metals and polymers are reported and compared with quasistatic and split Hopkinson pressure bar results.

  17. Thrust initiation and its control on tectonic wedge geometry: An insight from physical and numerical models

    Science.gov (United States)

    Bose, Santanu; Mandal, Nibir; Saha, Puspendu; Sarkar, Shamik; Lithgow-Bertelloni, Carolina

    2014-10-01

    We performed a series of sandbox experiments to investigate the initiation of thrust ramping in tectonic wedges on a mechanically continuous basal decollement. The experiments show that the decollement slope (β) is the key factor in controlling the location of thrust initiation with respect to the backstop (i.e. tectonic suture line). For β = 0, the ramping begins right at the backstop, followed by sequential thrusting in the frontal direction, leading to a typical mono-vergent wedge. In contrast, the ramp initiates away from the backstop as β > 0. Under this boundary condition an event of sequential back thrusting takes place prior to the onset of frontal thrust progression. These two-coupled processes eventually give rise to a bi-vergent geometry of the thrust wedge. Using the Drucker-Prager failure criterion in finite element (FE) models, we show the location of stress intensification to render a mechanical basis for the thrust initiation away from the backstop if β > 0. Our physical and FE model results explain why the Main Central Thrust (MCT) is located far away from the Indo-Tibetan plate contact (ITSZ) in the Himalayan fold-and-thrust belts.

  18. Flat synchronizations in spherically symmetric space-times

    International Nuclear Information System (INIS)

    Herrero, Alicia; Morales-Lladosa, Juan Antonio

    2010-01-01

    It is well known that the Schwarzschild space-time admits a spacelike slicing by flat instants and that the metric is regular at the horizon in the associated adapted coordinates (Painleve-Gullstrand metric form). We consider this type of flat slicings in an arbitrary spherically symmetric space-time. The condition ensuring its existence is analyzed, and then, we prove that, for any spherically symmetric flat slicing, the densities of the Weinberg momenta vanish. Finally, we deduce the Schwarzschild solution in the extended Painleve-Gullstrand-LemaItre metric form by considering the coordinate decomposition of the vacuum Einstein equations with respect to a flat spacelike slicing.

  19. Automated Mounting of Pole-Shoe Wedges in Linear Wave Power Generators—Using Industrial Robotics and Proximity Sensors

    Directory of Open Access Journals (Sweden)

    Tobias Kamf

    2017-03-01

    Full Text Available A system for automatic mounting of high tolerance wedges inside a wave power linear generator is proposed. As for any renewable energy concept utilising numerous smaller generation units, minimising the production cost per unit is vital for commercialization. The linear generator in question uses self-locking wedges, which are challenging to mount using industrial robots due to the high tolerances used, and because of the fact that any angular error remaining after calibration risks damaging the equipment. Using two types of probes, mechanical touch probes and inductive proximity sensors, combined with a flexible robot tool and iterative calibration routines, an automatic mounting system that overcomes the challenges of high tolerance wedge mounting is presented. The system is experimentally verified to work at mounting speeds of up to 50mm/s, and calibration accuracies of 0.25mmand 0.1 ∘ are achieved. The use of a flexible robot tool, able to move freely in one Cartesian plane, was found to be essential for making the system work.

  20. New Transition Wedge Design Composed by Prefabricated Reinforced Concrete Slabs

    OpenAIRE

    Real-Herráiz, Julia; Zamorano-Martín, Clara; Real-Herráiz, Teresa; Morales-Ivorra, Silvia

    2016-01-01

    [EN] Important track degradation occurs in structure-embankment transitions, in which an abrupt change in track vertical stiffness arises, leading to a reduction in passengers comfort and safety. Although granular wedges are suggested by different railroad administrations as a solution to avoid these problems, they present some disadvantages which may affect track long-term performance. In this paper, a new solution designed with prefabricated reinforced concrete slabs is proposed. The aim of...

  1. TRANSVERSE MODES FOR FLAT INTER-BUNCH WAKES*

    CERN Document Server

    Burov, A

    2013-01-01

    If inter-bunch wake fields are flat, i.e. their variations over a bunch length can be neglected, all coherent modes have the same coupled-bunch structure, provided the bunches can be treated as identical by their inner qualities (train theorem). If a flat feedback is strong enough, the transverse modes are single-bunch, provided the inter-bunch wakes are also flat (damper theorem).

  2. Reduced emissions of greenhouse gases 2050: Technological wedges - Input to the Commission on Low Emissions; Reduserte klimagassutslipp 2050: Teknologiske kiler - Innspill til Lavutslippsutvalget

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, Eva; Espegren, Kari Aamodt; Finden, Per; Hageman, Rolf; Stenersen, Dag

    2006-09-15

    The Commission on Low Emissions was established in March 2005 and has been charged with the task of describing how Norway can achieve a 50-80 percent reduction in emissions of greenhouse gases by 2050. The commission describes the desired total reduction in emissions to be a set of actions or 'wedges', meaning that the reduction in emissions are linked to an array of technological and behavioural changes. The technological wedges are described here, while the behavioural wedges are treated in a different report. The potentials described are based on the Low Emission's reference line. Possible changes in the reference line will result in changed potentials. The technological wedges studied comprise to a great extent a potential of 50-80 percent reduction in greenhouse gases by 2050. This depends on considerable effort from research and development, and a determination to change external conditions.

  3. Numerical simulation for heat transfer performance in unsteady flow of Williamson fluid driven by a wedge-geometry

    Science.gov (United States)

    Hamid, Aamir; Hashim; Khan, Masood

    2018-06-01

    The main concern of this communication is to investigate the two-layer flow of a non-Newtonian rheological fluid past a wedge-shaped geometry. One remarkable aspect of this article is the mathematical formulation for two-dimensional flow of Williamson fluid by incorporating the effect of infinite shear rate viscosity. The impacts of heat transfer mechanism on time-dependent flow field are further studied. At first, we employ the suitable non-dimensional variables to transmute the time-dependent governing flow equations into a system of non-linear ordinary differential equations. The converted conservation equations are numerically integrated subject to physically suitable boundary conditions with the aid of Runge-Kutta Fehlberg integration procedure. The effects of involved pertinent parameters, such as, moving wedge parameter, wedge angle parameter, local Weissenberg number, unsteadiness parameter and Prandtl number on the non-dimensional velocity and temperature distributions have been evaluated. In addition, the numerical values of the local skin friction coefficient and the local Nusselt number are compared and presented through tables. The outcomes of this study indicate that the rate of heat transfer increases with the growth of both wedge angle parameter and unsteadiness parameter. Moreover, a substantial rise in the fluid velocity is observed with enhancement in the viscosity ratio parameter while an opposite trend is true for the non-dimensional temperature field. A comparison is presented between the current study and already published works and results found to be in outstanding agreement. Finally, the main findings of this article are highlighted in the last section.

  4. Theoretical research of probability of wedging of particulate matters at polishing

    Directory of Open Access Journals (Sweden)

    V.F. Molchanov

    2017-12-01

    Full Text Available The mechanism of formation of mikroprofile of the polished surface is expounded taking into account influence of particulate matters, contained in lubricating-coolings liquids. Probability of wedging of abrasive particles is investigational in the area of contact of diamond-impregnated with the surface of detail. It is set that for determination of probability of event, when a particle, getting together with a liquid in the area of contact, abandons track-scratch on a superficial layer, it is necessary to take into account, that three mutual locations of hard particle are possible in the area of contact of diamond-impregnated with the surface of detail. It is set researches, that a hard particle, getting together with a liquid in the area of contact, abandons track-scratch on-the-spot in that case, when the sizes of particle are equal or a few exceed distance from the surface of detail to the ledges on-the-spot diamond-impregnated. Researches allow mathematically to define probability of wedging of particulate matters in the area of contact of diamond-impregnated with the surface of the polished detail.

  5. SAID/SAPS Revisited: A Causal Relation to the Substorm Current Wedge

    Science.gov (United States)

    Mishin, E. V.

    2017-12-01

    We present multi-spacecraft observations of enhanced flow/electric field channels in the inner magnetosphere and conjugate subauroral ionosphere, i.e., subauroral polarization streams (SAPS) near dusk and subauroral ion drifts (SAID) near midnight. The channels collocate with ring current (RC) injections lagging the onset of substorms by a few to ˜20 minutes, i.e., significantly shorter than the gradient-curvature drift time of tens of keV ions. The time lag is of the order of the propagation time of reconnection-injected hot plasma jets to the premidnight plasmasphere and the substorm current wedge (SCW) to dusk. The observations confirm and expand on the previous results on the SAID features that negate the paradigm of voltage and current generators. Fast-time duskside SAPS/RC injections appear intimately related to a two-loop circuit of the substorm current wedge (SCW2L). We suggest that the poleward electric field inherent in the SCW2L circuit, which demands closure of the Region 1- and Region 2-sense field-aligned currents via meridional currents, is the ultimate cause of fast RC injections and SAPS on the duskside.

  6. Wetting of flat gradient surfaces.

    Science.gov (United States)

    Bormashenko, Edward

    2018-04-01

    Gradient, chemically modified, flat surfaces enable directed transport of droplets. Calculation of apparent contact angles inherent for gradient surfaces is challenging even for atomically flat ones. Wetting of gradient, flat solid surfaces is treated within the variational approach, under which the contact line is free to move along the substrate. Transversality conditions of the variational problem give rise to the generalized Young equation valid for gradient solid surfaces. The apparent (equilibrium) contact angle of a droplet, placed on a gradient surface depends on the radius of the contact line and the values of derivatives of interfacial tensions. The linear approximation of the problem is considered. It is demonstrated that the contact angle hysteresis is inevitable on gradient surfaces. Electrowetting of gradient surfaces is discussed. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Flat detectors and their clinical applications

    International Nuclear Information System (INIS)

    Spahn, Martin

    2005-01-01

    Diagnostic and interventional flat detector X-ray systems are penetrating the market in all application segments. First introduced in radiography and mammography, they have conquered cardiac and general angiography and are getting increasing attention in fluoroscopy. Two flat detector technologies prevail. The dominating method is based on an indirect X-ray conversion process, using cesium iodide scintillators. It offers considerable advantages in radiography, angiography and fluoroscopy. The other method employs a direct converter such as selenium which is particularly suitable for mammography. Both flat detector technologies are based on amorphous silicon active pixel matrices. Flat detectors facilitate the clinical workflow in radiographic rooms, foster improved image quality and provide the potential to reduce dose. This added value is based on their large dynamic range, their high sensitivity to X-rays and the instant availability of the image. Advanced image processing is instrumental in these improvements and expand the range of conventional diagnostic methods. In angiography and fluoroscopy the transition from image intensifiers to flat detectors is facilitated by ample advantages they offer, such as distortion-free images, excellent coarse contrast, large dynamic range and high X-ray sensitivity. These characteristics and their compatibility with strong magnetic fields are the basis for improved diagnostic methods and innovative interventional applications. (orig.)

  8. Flat-ramp vs. convex-concave thrust geometries in a deformable hanging wall: new insights from analogue modeling experiments

    Science.gov (United States)

    Almeida, Pedro; Tomas, Ricardo; Rosas, Filipe; Duarte, Joao; Terrinha, Pedro

    2015-04-01

    Different modes of strain accommodation affecting a deformable hanging-wall in a flat-ramp-flat thrust system were previously addressed through several (sandbox) analog modeling studies, focusing on the influence of different variables, such as: a) thrust ramp dip angle and friction (Bonini et al, 2000); b) prescribed thickness of the hanging-wall (Koy and Maillot, 2007); and c) sin-thrust erosion (compensating for topographic thrust edification, e.g. Persson and Sokoutis, 2002). In the present work we reproduce the same experimental procedure to investigate the influence of two different parameters on hanging-wall deformation: 1) the geometry of the thrusting surface; and 2) the absence of a velocity discontinuity (VD) that is always present in previous similar analogue modeling studies. Considering the first variable we use two end member ramp geometries, flat-ramp-flat and convex-concave, to understand the control exerted by the abrupt ramp edges in the hanging-wall stress-strain distribution, comparing the obtain results with the situation in which such edge singularities are absent (convex-concave thrust ramp). Considering the second investigated parameter, our motivation was the recognition that the VD found in the different analogue modeling settings simply does not exist in nature, despite the fact that it has a major influence on strain accommodation in the deformable hanging-wall. We thus eliminate such apparatus artifact from our models and compare the obtained results with the previous ones. Our preliminary results suggest that both investigated variables play a non-negligible role on the structural style characterizing the hanging-wall deformation of convergent tectonic settings were such thrust-ramp systems were recognized. Acknowledgments This work was sponsored by the Fundação para a Ciência e a Tecnologia (FCT) through project MODELINK EXPL/GEO-GEO/0714/2013. Pedro Almeida wants to thank to FCT for the Ph.D. grant (SFRH/BD/52556/2014) under the

  9. Metamaterials based on wedge-shaped electrodynamic structures

    Directory of Open Access Journals (Sweden)

    Mitrokhin Vladimir

    2017-01-01

    Full Text Available The paper studies a possibility of simulation of artificial composite media with negative values of the real part of the equivalent dielectric (magnetic permittivity, by the use of segments of hollow composite waveguides with cylindrical guided waves in evanescent mode. Reactive evanescent fields of wedge-shaped waveguide eigenmodes are formed in the evanescent region before the critical section of the waveguide which separates the quasistatic field region from the distributing field of the evanescent waveguide mode. The possibility of simulation is determined by the equivalence of dispersion equation of the eigenmode propagation constant and the dispersion equation for the electric (magnetic permittivity of plasma-like medium if cut-off frequency and electric (magnetic plasma frequency of the medium are equal.

  10. Vasculitic peripheral neuropathy

    Directory of Open Access Journals (Sweden)

    Mona Amini

    2014-02-01

    Full Text Available Primary systemic vasculitis in pre-capillary arteries is associated with peripheral neuropathy. In some types of systematic vasculitis about 60 % of patients have peripheral nervous system (PNS involvement. In vasculitic peripheral neuropathies (VPN a necrotizing and inflammatory process leads to narrowing of vasa nervorum lumen and eventually the appearance of ischemic lesions in peripheral nerves. Some features might be suggestive of VPN, like: axonal nerve degeneration, wallerian-like degeneration, and diameter irregularity of nerve. Peripheral nervous system (PNS destruction during systemic vasculitides should be considered, due to its frequency and early occurrence in vasculitis progression. The first line treatment of non systematic VPNs is corticosteroid agents, but these drugs might worsen the VPNs or systemic vasculitis.

  11. Laser Doppler thermometry in flat flames

    NARCIS (Netherlands)

    Maaren, van A.; Goey, de L.P.H.

    1994-01-01

    Laser Doppler Velocimetry measurements are performed in flat flames, stabilized on a newly developed flat-flame burner. It is shown that the velocity component perpendicular to the main flow direction, induced by expansion in the reaction zone and buoyancy in the burnt gas, is significant. A method

  12. Open wedge metatarsal osteotomy versus crescentic osteotomy to correct severe hallux valgus deformity

    DEFF Research Database (Denmark)

    Wester, Jens Ulrik; Hamborg-Petersen, Ellen; Herold, Niels

    2016-01-01

    BACKGROUND: Different techniques of proximal osteotomies have been introduced to correct severe hallux valgus. The open wedge osteotomy is a newly introduced method for proximal osteotomy. The aim of this prospective randomized study was to compare the radiological and clinical results after...... operation for severe hallux valgus, comparing the open wedge osteotomy to the crescentic osteotomy which is our traditional treatment. METHODS: Forty-five patients with severe hallux valgus (hallux valgus angle >35̊, and intermetatarsal angle >15̊) were included in this study. The treatment was proximal...... and 12 months after the operation. RESULTS: In group 1 the hallux valgus angle decreased from 39.0̊ to 24.1̊ after 4 months and 27.9̊ after 12 months. In group 2 the angle decreased from 38.3̊ to 21.4̊ after 4 months and 27.0̊ after 12 months. The intermetatarsal angle in group 1 was 19.0̊ preoperatively...

  13. Diffraction of an inhomogeneous plane wave by an impedance wedge in a lossy medium

    CSIR Research Space (South Africa)

    Manara, G

    1998-11-01

    Full Text Available The diffraction of an inhomogeneous plane wave by an impedance wedge embedded in a lossy medium is analyzed. The rigorous integral representation for the field is asymptotically evaluated in the context of the uniform geometrical theory...

  14. Role of Neogene Exhumation and Sedimentation on Critical-Wedge Kinematics in the Zagros Orogenic Belt, Northeastern Iraq, Kurdistan

    Science.gov (United States)

    Koshnaw, R. I.; Horton, B. K.; Stockli, D. F.; Barber, D. E.; Tamar-Agha, M. Y.; Kendall, J. J.

    2014-12-01

    The Zagros orogenic belt and foreland basin formed during the Cenozoic Arabia-Eurasia collision, but the precise histories of shortening and sediment accumulation remain ambiguous, especially at the NW extent of the fold-thrust belt in Iraqi Kurdistan. This region is characterized by well-preserved successions of Cenozoic clastic foreland-basin fill and deformed Paleozoic-Mesozoic hinterland bedrock. The study area provides an excellent opportunity to investigate the linkage between orogenic wedge behavior and surface processes of erosion and deposition. The aim of this research is to test whether the Zagros orogenic wedge advanced steadily under critical to supercritical wedge conditions involving in-sequence thrusting with minimal erosion or propagated intermittently under subcritical condition involving out-of-sequence deformation with intense erosion. These endmember modes of mountain building can be assessed by integrating geo/thermochronologic and basin analyses techniques, including apatite (U-Th)/He thermochronology, detrital zircon U-Pb geochronology, stratigraphic synthesis, and seismic interpretations. Preliminary apatite (U-Th)/He data indicate activation of the Main Zagros Fault (MZF) at ~10 Ma with frontal thrusts initiating at ~8 Ma. However, thermochronometric results from the intervening Mountain Front Flexure (MFF), located between the MZF and the frontal thrusts, suggest rapid exhumation at ~6 Ma. These results suggest that the MFF, represented by the thrust-cored Qaradagh anticline, represents a major episode of out-of-sequence deformation. Detrital zircon U-Pb analyses from the Neogene foreland-basin deposits show continuous sediment derivation from sources to the NNE in Iraq and western Iran, suggesting that out-of-sequence thrusting did not significantly alter sedimentary provenance. Rather, intense hinterland erosion and recycling of older foreland-basin fill dominated sediment delivery to the basin. The irregular distribution of

  15. An epidemiologic study of flat foot in Iran

    Directory of Open Access Journals (Sweden)

    Alamy B

    1997-07-01

    Full Text Available Among 880 studied feet of 7-14 years old children 6.9% suffered mild and severe flat foot. 53.8% of the affected children were symptomatic. As 40.1% of the general population experiences symptoms, in a small proportion of affected persons, symptoms are due to flat foot. The prevalence of symptoms rises with increasing severity of the disorder. In this article, reviewing general aspects of flat food, prevalence and other epidemiological aspects of flat foot for the first time in Iran have been presented

  16. Peripheral biomarkers revisited: integrative profiling of peripheral samples for psychiatric research.

    Science.gov (United States)

    Hayashi-Takagi, Akiko; Vawter, Marquis P; Iwamoto, Kazuya

    2014-06-15

    Peripheral samples, such as blood and skin, have been used for decades in psychiatric research as surrogates for central nervous system samples. Although the validity of the data obtained from peripheral samples has been questioned and other state-of-the-art techniques, such as human brain imaging, genomics, and induced pluripotent stem cells, seem to reduce the value of peripheral cells, accumulating evidence has suggested that revisiting peripheral samples is worthwhile. Here, we re-evaluate the utility of peripheral samples and argue that establishing an understanding of the common signaling and biological processes in the brain and peripheral samples is required for the validity of such models. First, we present an overview of the available types of peripheral cells and describe their advantages and disadvantages. We then briefly summarize the main achievements of omics studies, including epigenome, transcriptome, proteome, and metabolome analyses, as well as the main findings of functional cellular assays, the results of which imply that alterations in neurotransmission, metabolism, the cell cycle, and the immune system may be partially responsible for the pathophysiology of major psychiatric disorders such as schizophrenia. Finally, we discuss the future utility of peripheral samples for the development of biomarkers and tailor-made therapies, such as multimodal assays that are used as a battery of disease and trait pathways and that might be potent and complimentary tools for use in psychiatric research. © 2013 Society of Biological Psychiatry Published by Society of Biological Psychiatry All rights reserved.

  17. Evaluation of the deformation value of an optical flat under gravity

    International Nuclear Information System (INIS)

    Kondo, Yohan; Bitou, Youichi

    2014-01-01

    The flatness of an optical surface can be evaluated using a Fizeau interferometer. There is strong demand for ensuring that the measurement uncertainty of flatness is of nanometer order over a measurement range of 300 mm or more; however, the measurement range and measurement uncertainty of flatness at the National Metrology Institute of Japan (NMIJ) are 300 mm and 10 nm, respectively. In a Fizeau flatness interferometer, the gap distance between the reference flat and the specimen is measured. To obtain the absolute profile of the specimen, the absolute profile of the reference flat should be measured in advance. The three-flat test is one of the methods used to measure the absolute profile of a reference flat. The reference flat, however, deforms under the force of gravity, and its absolute deformation value cannot be determined by the three-flat test. The deformation value of the reference flat can be corrected by the finite element method (FEM) analysis; however, it is difficult to ensure the validity of the analysis and there is a large uncertainty component of the Fizeau flatness interferometer. To verify the FEM analysis, we developed a scanning deflectometric profiler (SDP) that does not require a reference flat and can directly measure a profile. We calibrated an optical flat using a Fizeau flatness interferometer and the SDP. Finally, the deformation value of the reference flat under the force of gravity was evaluated by comparing the measurement results. (paper)

  18. On the role of lateral waves in the radiation from the dielectric wedge

    DEFF Research Database (Denmark)

    Balling, Peter

    1973-01-01

    The field on the dielectric wedge is approximated by a plane-wave expansion as in [1]. Contributions from this solution to both the surface field and the radiation field are examined. Finally, an experimental radiation field is compared with the plane-wave solution and with a geometric-optical...

  19. Instability of flat space at finite temperature

    International Nuclear Information System (INIS)

    Gross, D.J.; Perry, M.J.; Yaffe, L.G.

    1982-01-01

    The instabilities of quantum gravity are investigated using the path-integral formulation of Einstein's theory. A brief review is given of the classical gravitational instabilities, as well as the stability of flat space. The Euclidean path-integral representation of the partition function is employed to discuss the instability of flat space at finite temperature. Semiclassical, or saddle-point, approximations are utilized. We show how the Jeans instability arises as a tachyon in the graviton propagator when small perturbations about hot flat space are considered. The effect due to the Schwarzschild instanton is studied. The small fluctuations about this instanton are analyzed and a negative mode is discovered. This produces, in the semiclassical approximation, an imaginary part of the free energy. This is interpreted as being due to the metastability of hot flat space to nucleate black holes. These then evolve by evaporation or by accretion of thermal gravitons, leading to the instability of hot flat space. The nucleation rate of black holes is calculated as a function of temperature

  20. Flat-panel detectors in x-ray diagnosis

    International Nuclear Information System (INIS)

    Spahn, M.; Heer, V.; Freytag, R.

    2003-01-01

    For all application segments X-ray systems with flat-panel detectors increasingly enter the market. In digital radiography, mammography and cardiologic angiography flat-panel detectors are already well established while they are made ready for market introduction in general angiography and fluoroscopy. Two flat-panel detector technologies are available. One technology is based on an indirect conversion process of X-rays while the other one uses a direct conversion method.For radiography and dynamic applications the indirect method provides substantial advantages, while the direct method has some benefits for mammography. In radiography and mammography flat-panel detectors lead to clear improvements with respect to workflow, image quality and dose reduction potentials. These improvements are fostered by the immediate availability of the image, the large dynamic range and the high sensitivity to X-rays. New applications and the use of complex image processing algorithms have the potential to enlarge the present diagnostic range of applications.Up to now, image intensifiers are still the well-established technology for angiography and fluoroscopy. Nevertheless flat-panel detectors begin to enter this field, especially in cardiologic angiography.Characteristics of flat-panel detectors such as the availability of distortion-free images, the excellent contrast resolution, the large dynamic range, the high sensitivity to X-rays and the usability in magnetic fields provide the basis for improved and new diagnostic and interventional methods. (orig.) [de

  1. Muon Intensity Increase by Wedge Absorbers for Low-E Muon Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Neuffer, D. V. [Fermilab; Stratakis, D. [Fermilab; Bradley, J. [Fermilab

    2017-09-01

    Low energy muon experiments such as mu2e and g-2 have a limited energy spread acceptance. Following techniques developed in muon cooling studies and the MICE experiment, the number of muons within the desired energy spread can be increased by the matched use of wedge absorbers. More generally, the phase space of muon beams can be manipulated by absorbers in beam transport lines. Applications with simulation results are presented.

  2. General classification of a normally flat Ric- semi symmetric submanifolds

    International Nuclear Information System (INIS)

    Mirzoyan, V.A.

    2012-01-01

    It has been proved that a normally flat submanifold M in Euclidean space En satisfies the condition R(X,Y)Ricci =0 if and only if it is the open part of one of the following submanifolds: (1) normally flat two-dimensional submanifold, (2) normally flat Einstein submanifold (in particular Ricci-flat or locally Euclidean), (3) normally flat semi- Einstein submanifold, (4) normally flat interlacing product of semi-Einstein submanifolds and locally Euclidean submanifold (may be of zero dimension), (5) direct product of the above enumerated classes of submanifolds

  3. Numerical Simulation and Experimental Validation of an Integrated Sleeve-Wedge Anchorage for CFRP Rods

    DEFF Research Database (Denmark)

    Schmidt, Jacob Wittrup; Smith, Scott T.; Täljsten, Björn

    2011-01-01

    . Recently, an integrated sleeve-wedge anchorage has been successfully developed specifically for CFRP rods. This paper in turn presents a numerical simulation of the newly developed anchorage using ABAQUS. The three-dimensional finite element (FE) model, which considers material non-linearity, uses...

  4. A study to compare the motorised wedge output factor of an elekta synergy linear accelerator with reference data (TPS Data)

    International Nuclear Information System (INIS)

    Akosah, Kinsley

    2016-07-01

    For external beam radiotherapy treatments, high doses are delivered to the cancerous cell. Accuracy and precision of dose delivery are primary requirements for effective and efficient cancer treatment. The dose delivered to the patient might not be uniform and therefore need to be compensated for. In treatment these inhomogeneities are taken care of by using wedge filters and incorporating wedge factors in the Treatment Planning System. Computer controlled wedges were alternatives introduced by different manufacturers of which Motorized wedges (MW) is one of them. The MW was introduced by ELEKTA and this helps to overcome some of the shortcomings of physical wedges. The objectives of this study were to measure MW output factors for 6 MV and 15 MV photon energies for an ELEKTA Synergy. Secondly, to compare the results of MWOF obtained to that of the treatment planning system data. The Motorized Wedge Output Factors (MWOF) were measured for the ELEKTA Synergy for both 6 MV and 15 MV photon energies. With the help of PMMA solid water slabs phantom, the Elekta synergy, thermometer, barometer, PTW farmer type ionization chamber 30010 charges were collected at 100 cm source to surface distance for various square field sizes from 5x5 cm to 30x30 cm and depth of 1.5 cm and 2.5 cm for 6 MV and 15 MV photon energies. Comparing the results with the TPS data, an excellent agreement was found for 6 MV MWOF, with the percentage differences ranging from 0.03% to 1.50%, with a mean of 0.03%. The coefficient of variation of MWOF ranged from 0.023% to 1.07% and 0.001% to 12.89% for the two beams (6 MV and 15 MV) respectively. The relative differences between the calculated and the measured MWOFs increases with field size. In conclusion, there was general agreement between the calculated and measured MWOFs. The consistency of values provide further support that a standard dataset of photon and electron dosimetry could be established as a guide for future commissioning, beam modeling

  5. 3D flat holography: entropy and logarithmic corrections

    International Nuclear Information System (INIS)

    Bagchi, Arjun; Basu, Rudranil

    2014-01-01

    We compute the leading corrections to the Bekenstein-Hawking entropy of the Flat Space Cosmological (FSC) solutions in 3D flat spacetimes, which are the flat analogues of the BTZ black holes in AdS 3 . The analysis is done by a computation of density of states in the dual 2D Galilean Conformal Field Theory and the answer obtained by this matches with the limiting value of the expected result for the BTZ inner horizon entropy as well as what is expected for a generic thermodynamic system. Along the way, we also develop other aspects of holography of 3D flat spacetimes

  6. Computational Design of Flat-Band Material

    Science.gov (United States)

    Hase, I.; Yanagisawa, T.; Kawashima, K.

    2018-02-01

    Quantum mechanics states that hopping integral between local orbitals makes the energy band dispersive. However, in some special cases, there are bands with no dispersion due to quantum interference. These bands are called as flat band. Many models having flat band have been proposed, and many interesting physical properties are predicted. However, no real compound having flat band has been found yet despite the 25 years of vigorous researches. We have found that some pyrochlore oxides have quasi-flat band just below the Fermi level by first principles calculation. Moreover, their valence bands are well described by a tight-binding model of pyrochlore lattice with isotropic nearest neighbor hopping integral. This model belongs to a class of Mielke model, whose ground state is known to be ferromagnetic with appropriate carrier doping and on-site repulsive Coulomb interaction. We have also performed a spin-polarized band calculation for the hole-doped system from first principles and found that the ground state is ferromagnetic for some doping region. Interestingly, these compounds do not include magnetic element, such as transition metal and rare-earth elements.

  7. Long-term outcomes of wedge resection at the limbus for high irregular corneal astigmatism after repaired corneal laceration

    Directory of Open Access Journals (Sweden)

    Jun Du

    2016-06-01

    Full Text Available AIM: To evaluate the clinical value of wedge resection at corneal limbus in patients with traumatic corneal scarring and high irregular astigmatism. METHODS: Patients with traumatic corneal astigmatism received wedge resection at least 6mo after suture removal from corneal wound. The uncorrected distance visual acuities (UCVA and best corrected distance visual acuities (BCVA, pre- and post-operation astigmatism, spherical equivalent (SE, safety and complications were evaluated. RESULTS: Ten eyes (10 patients were enrolled in this study. Mean follow-up time after wedge resection was 37.8±15.4mo (range, 20-61mo. The mean UCVA improved from +1.07±0.55 logMAR to +0.43±0.22 logMAR (P=0.000 and the mean BCVA from +0.50±0.30 logMAR to +0.15±0.17 logMAR (P=0.000. The mean astigmatism power measured by retinoscopy was -2.03±2.27 D postoperatively and -2.83±4.52 D preoperatively (P=0.310. The mean SE was -0.74±1.61 D postoperatively and -0.64±1.89 D preoperatively (P=0.601. Two cases developed mild pannus near the sutures. No corneal perforation, infectious keratitis or wound gape occurred. CONCLUSION: Corneal-scleral limbal wedge resection with compression suture is a safe, effective treatment for poor patients with high irregular corneal astigmatism after corneal-scleral penetrating injury. Retinoscopy can prove particularly useful for high irregular corneal astigmatism when other measurements are not amenable.

  8. Two-dimensional electronic spectroscopy with birefringent wedges

    Energy Technology Data Exchange (ETDEWEB)

    Réhault, Julien; Maiuri, Margherita; Oriana, Aurelio; Cerullo, Giulio [IFN-CNR, Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano (Italy)

    2014-12-15

    We present a simple experimental setup for performing two-dimensional (2D) electronic spectroscopy in the partially collinear pump-probe geometry. The setup uses a sequence of birefringent wedges to create and delay a pair of phase-locked, collinear pump pulses, with extremely high phase stability and reproducibility. Continuous delay scanning is possible without any active stabilization or position tracking, and allows to record rapidly and easily 2D spectra. The setup works over a broad spectral range from the ultraviolet to the near-IR, it is compatible with few-optical-cycle pulses and can be easily reconfigured to two-colour operation. A simple method for scattering suppression is also introduced. As a proof of principle, we present degenerate and two-color 2D spectra of the light-harvesting complex 1 of purple bacteria.

  9. Peripheral reactions

    International Nuclear Information System (INIS)

    Greiner, D.

    1978-01-01

    Peripheral collisions, that is, collisions involving a small amount of overlap of nuclear matter, are discussed including inclusive interactions, the magnitude of the peripheral cross section, fragmentation, a compilation of experiments and available data, limiting fragmentation, factorization, some models, fragment momentum distributions, and future research directions

  10. Total Hip Intraoperative Femur Fracture: Do the Design Enhancements of a Second-Generation Tapered-Wedge Stem Reduce the Incidence?

    Science.gov (United States)

    Colacchio, Nicholas D; Robbins, Claire E; Aghazadeh, Mehran S; Talmo, Carl T; Bono, James V

    2017-10-01

    Intraoperative femur fracture (IFF) is a well-known complication in primary uncemented total hip arthroplasty (THA). Variations in implant instrumentation design and operative technique may influence the risk of IFF. This study investigates IFF between a standard uncemented tapered-wedge femoral stem and its second-generation successor with the following design changes: size-specific medial curvature, proportional incremental stem growth, modest reduction in stem length, and distal lateral relief. A single experienced surgeon's patient database was retrospectively queried for IFF occurring during primary uncemented THA using a standard tapered-wedge femoral stem system or a second-generation stem. All procedures were performed using soft tissue preserving anatomic capsule repair and posterior approach. The primary outcome measure was IFF. A z-test of proportions was performed to determine significant difference between the 2 stems with respect to IFF. Patient demographics, Dorr classification, and implant characteristics were also examined. Forty-one of 1510 patients (2.72%) who received a standard tapered-wedge femoral stem sustained an IFF, whereas 5 of 800 patients (0.63%) using the second-generation stem incurred an IFF. No other significant associations were found. A standard tapered-wedge femoral stem instrumentation system resulted in greater than 4 times higher incidence of IFF than its second-generation successor used for primary uncemented THA. Identifying risk factors for IFF is necessary to facilitate implant system improvements and thus maximize patient outcomes. Copyright © 2017. Published by Elsevier Inc.

  11. Monte Carlo simulation of the Varian Clinac 600C accelerator using dynamic wedges; Simulacao Monte Carlo do acelerador Varian Clinac 600C utilizando cunhas dinamicas

    Energy Technology Data Exchange (ETDEWEB)

    Moreno, S. [Universidade da Beira Interior (UBI), Covilha (Portugal); Chaves, A.; Lopes, M.C. [Instituto Portugues de Oncologia Doutor Francisco Gentil (IPO), Coimbra (Portugal); Peralta, L. [Laboratorio de Instrumentacao e Fisica Experimental de Particulas (LIP), Lisboa (Portugal)]|[Universidade de Lisboa (Portugal). Faculdade de Ciencias

    2004-07-01

    The advent of linear accelerators (linac) with computer-controlled dynamic collimation systems and functional and anatomical imaging techniques allowed a more exact delimitation and localisation of the target volume. These advanced treatment techniques inevitably increase the complexity level of dose calculation because of the introduction of the temporal variable. On account of this, it is mandatory the usage of more accurate modelling techniques of the collimator components, as it is the case of Monte Carlo (MC) simulation, which has created an enormous interest in research and clinical practice. Because the patients bodies are not homogenous nor are their body surfaces plane and regular, the dose distribution may differ significantly from the standard distribution from the linac calibration. It is in the treatment planning systems, which include algorithms that are usually measured in homogeneous water phantoms specific for each correction that the dose distributions from each case are obtained. In a real treatment, exception made to superficial lesions, two or more radiation fields are used in order to obtain the recommended dose distributions. The simplest arrangement is made from two parallel and opposed fields that originate a homogeneous dose distribution in almost all the irradiated volume. The available resources are, for example, different types of energies and of radiation, the application of bolus, the protection of healthy structures, the usage of wedged filters and the application of dynamic wedges. A virtual or dynamic wedge, modelled through the movement of one of the jaws, when compared with a set of physical wedges offers an alternative calculation method of an arbitrary number of wedged fields, instead of the four traditional fields of 15 deg, 30 deg, 45 deg and 60 deg angle and obtained with physical wedges. The goal of this work consists in the study of the application of dynamic wedges in tailoring the radiation field by the Varian Clinac 600

  12. HF wedge #1" detail of the wedge tip taken at VNIITF in the construction workshop. The jig mounted on top is used to measure the conformity to the drawings.

    CERN Multimedia

    Official photographer of VNIITF (photo scanned by T. Camporesi)

    2001-01-01

    The photo has been taken as documetation of the acceptance procedure of the first wedge for the very forward calorimeter of CMS (HF). The detail shows the holes where the quartz fibers are going to be stuffed and the jig used to measure that the geometry was within the specified tolerances and that the geometry alignement track was conforming to the specifications.

  13. Technical note: A new wedge-shaped ionization chamber component module for BEAMnrc to model the integral quality monitoring system®

    Science.gov (United States)

    Oderinde, Oluwaseyi Michael; du Plessis, FCP

    2017-12-01

    The purpose of this study was to develop a new component module (CM) namely IQM to accurately model the integral quality monitoring (IQM) system® to be used in the BEAMnrc Monte Carlo (MC) code. The IQM is essentially a double wedge ionization chamber with the central electrode plate bisecting the wedge. The IQM CM allows the user to characterize the double wedge of this ionization chamber and BEAMnrc can then accurately calculate the dose in this CM including its enclosed air regions. This has been verified against measured data. The newly created CM was added into the standard BEAMnrc CMs, and it will be made available through the NRCC website. The BEAMnrc graphical user interface (GUI) and particle ray-tracing techniques were used to validate the IQM geometry. In subsequent MC simulations, the dose scored in the IQM was verified against measured data over a range of square fields ranging from 1 × 1-30 × 30 cm2. The IQM system is designed for the present day need for a device that could verify beam output in real-time during treatment. This CM is authentic, and it can serve as a basis for researchers that have an interest in real-time beam delivery checking using wedge-shaped ionization chamber based instruments like the IQM.

  14. Secondary Subacromial Impingement after Valgus Closing-Wedge Osteotomy for Proximal Humerus Varus

    Directory of Open Access Journals (Sweden)

    Hirotaka Sano

    2015-01-01

    Full Text Available A 31-year-old construction worker had been suffering from both the motion pain and the restriction of elevation in his right shoulder due to severe varus deformity of humeral neck, which occurred after proximal humeral fracture. The angle for shoulder flexion and abduction was restricted to 50 and 80 degrees, respectively. Valgus closing-wedge osteotomy followed by the internal fixation using a locking plate was carried out at 12 months after injury. Postoperatively, the head-shaft angle of the humerus improved from 65 to 138 degrees. Active flexion and abduction angles improved from 80 to 135 degrees and from 50 to 135 degrees, respectively. However, the patient complained from a sharp pain with a clicking sound during shoulder abduction even after removal of the locking plate. Since subacromial steroid injection temporarily relieved his shoulder pain, we assumed that the secondary subacromial impingement was provoked after osteotomy. Thus, arthroscopic subacromial decompression was carried out at 27 months after the initial operation, which finally relieved his symptoms. In the valgus closing-wedge osteotomy, surgeons should pay attention to the condition of subacromial space to avoid causing the secondary subacromial impingement.

  15. Peripheral Developing Odontoma or Peripheral Ameloblastic Fibroodontoma: A Rare Challenging Case

    Directory of Open Access Journals (Sweden)

    Saede Atarbashi Moghadam

    2016-01-01

    Full Text Available Peripheral odontogenic lesions are considered to be rare within the classification of odontogenic tumors. They share the same microscopic characteristics of their central counterparts. Here, we report an ulcerated mass of the maxillary gingiva that on histopathological examination was diagnosed as peripheral developing odontoma or peripheral ameloblastic fibroodontoma. The diagnosis of this tumor is challenging and may lead to unnecessary treatment.

  16. Measuring linac photon beam energy through EPID image analysis of physically wedged fields

    Energy Technology Data Exchange (ETDEWEB)

    Dawoud, S. M., E-mail: samir.dawoud@leedsth.nhs.uk; Weston, S. J.; Bond, I.; Ward, G. C.; Rixham, P. A.; Mason, J.; Huckle, A. [Department of Medical Physics and Engineering, St. James Institute of Oncology, St. James University Hospital, Leeds LS9 7TF (United Kingdom); Sykes, J. R. [Institute of Medical Physics, School of Physics, The University of Sydney, New South Wales 2006, Australia and Department of Medical Physics and Engineering, St. James Institute of Oncology, St. James University Hospital, Leeds LS9 7TF (United Kingdom)

    2014-02-15

    Purpose: Electronic portal imaging devices (EPIDs) have proven to be useful tools for measuring several parameters of interest in linac quality assurance (QA). However, a method for measuring linac photon beam energy using EPIDs has not previously been reported. In this report, such a method is devised and tested, based on fitting a second order polynomial to the profiles of physically wedged beams, where the metric of interest is the second order coefficientα. The relationship between α and the beam quality index [percentage depth dose at 10 cm depth (PDD{sub 10})] is examined to produce a suitable calibration curve between these two parameters. Methods: Measurements were taken in a water-tank for beams with a range of energies representative of the local QA tolerances about the nominal value 6 MV. In each case, the beam quality was found in terms of PDD{sub 10} for 100 × 100 mm{sup 2} square fields. EPID images of 200 × 200 mm{sup 2} wedged fields were then taken for each beam and the wedge profile was fitted in MATLAB 2010b (The MathWorks, Inc., Natick, MA). α was then plotted against PDD{sub 10} and fitted with a linear relation to produce the calibration curve. The uncertainty in α was evaluated by taking five repeat EPID images of the wedged field for a beam of 6 MV nominal energy. The consistency of measuring α was found by taking repeat measurements on a single linac over a three month period. The method was also tested at 10 MV by repeating the water-tank crosscalibration for a range of energies centered approximately about a 10 MV nominal value. Finally, the calibration curve from the test linac and that from a separate clinical machine were compared to test consistency of the method across machines in a matched fleet. Results: The relationship betweenα and PDD{sub 10} was found to be strongly linear (R{sup 2} = 0.979) while the uncertainty in α was found to be negligible compared to that associated with measuring PDD{sub 10} in the water-tank (

  17. Flat epithelial atypia and atypical ductal hyperplasia: carcinoma underestimation rate.

    Science.gov (United States)

    Ingegnoli, Anna; d'Aloia, Cecilia; Frattaruolo, Antonia; Pallavera, Lara; Martella, Eugenia; Crisi, Girolamo; Zompatori, Maurizio

    2010-01-01

    This study was carried out to determine the underestimation rate of carcinoma upon surgical biopsy after a diagnosis of flat epithelial atypia and atypical ductal hyperplasia and 11-gauge vacuum-assisted breast biopsy. A retrospective review was conducted of 476 vacuum-assisted breast biopsy performed from May 2005 to January 2007 and a total of 70 cases of atypia were identified. Fifty cases (71%) were categorized as pure atypical ductal hyperplasia, 18 (26%) as pure flat epithelial atypia and two (3%) as concomitant flat epithelial atypia and atypical ductal hyperplasia. Each group were compared with the subsequent open surgical specimens. Surgical biopsy was performed in 44 patients with atypical ductal hyperplasia, 15 patients with flat epithelial atypia, and two patients with flat epithelial atypia and atypical ductal hyperplasia. Five cases of atypical ductal hyperplasia were upgraded to ductal carcinoma in situ, three cases of flat epithelial atypia yielded one ductal carcinoma in situ and two cases of invasive ductal carcinoma, and one case of flat epithelial atypia/atypical ductal hyperplasia had invasive ductal carcinoma. The overall rate of malignancy was 16% for atypical ductal hyperplasia (including flat epithelial atypia/atypical ductal hyperplasia patients) and 20% for flat epithelial atypia. The presence of flat epithelial atypia and atypical ductal hyperplasia at biopsy requires careful consideration, and surgical excision should be suggested.

  18. On-Line Flatness Measurement in the Steelmaking Industry

    Directory of Open Access Journals (Sweden)

    Rubén Usamentiaga

    2013-08-01

    Full Text Available Shape is a key characteristic to determine the quality of outgoing flat-rolled products in the steel industry. It is greatly influenced by flatness, a feature to describe how the surface of a rolled product approaches a plane. Flatness is of the utmost importance in steelmaking, since it is used by most downstream processes and customers for the acceptance or rejection of rolled products. Flatness sensors compute flatness measurements based on comparing the length of several longitudinal fibers of the surface of the product under inspection. Two main different approaches are commonly used. On the one hand, most mechanical sensors measure the tensile stress across the width of the rolled product, while manufacturing and estimating the fiber lengths from this stress. On the other hand, optical sensors measure the length of the fibers by means of light patterns projected onto the product surface. In this paper, we review the techniques and the main sensors used in the steelmaking industry to measure and quantify flatness defects in steel plates, sheets and strips. Most of these techniques and sensors can be used in other industries involving rolling mills or continuous production lines, such as aluminum, copper and paper, to name a few. Encompassed in the special issue, State-of-the-Art Sensors Technology in Spain 2013, this paper also reviews the most important flatness sensors designed and developed for the steelmaking industry in Spain.

  19. On-Line Flatness Measurement in the Steelmaking Industry

    Science.gov (United States)

    Molleda, Julio; Usamentiaga, Rubén; Garcίa, Daniel F.

    2013-01-01

    Shape is a key characteristic to determine the quality of outgoing flat-rolled products in the steel industry. It is greatly influenced by flatness, a feature to describe how the surface of a rolled product approaches a plane. Flatness is of the utmost importance in steelmaking, since it is used by most downstream processes and customers for the acceptance or rejection of rolled products. Flatness sensors compute flatness measurements based on comparing the length of several longitudinal fibers of the surface of the product under inspection. Two main different approaches are commonly used. On the one hand, most mechanical sensors measure the tensile stress across the width of the rolled product, while manufacturing and estimating the fiber lengths from this stress. On the other hand, optical sensors measure the length of the fibers by means of light patterns projected onto the product surface. In this paper, we review the techniques and the main sensors used in the steelmaking industry to measure and quantify flatness defects in steel plates, sheets and strips. Most of these techniques and sensors can be used in other industries involving rolling mills or continuous production lines, such as aluminum, copper and paper, to name a few. Encompassed in the special issue, State-of-the-Art Sensors Technology in Spain 2013, this paper also reviews the most important flatness sensors designed and developed for the steelmaking industry in Spain. PMID:23939583

  20. The results of high tibial open wedge osteotomy in patients with varus deformity

    Directory of Open Access Journals (Sweden)

    Mahmood Jabalameli

    2013-07-01

    Full Text Available Background: High tibial open wedg osteotomy is one of the most important modality for treatment of varus deformity in order to correct deformity and improving signs and symptoms of patients with primary degenerative osteoarthritis. The aim of this study was to investigate the results of high tibial open wedge osteotomy in patients with varus deformities.Methods: This retrospective study conducted on twenty nine patients (36 knees undergone proximal tibial osteotomy operation in Shafa Yahyaian University Hospital from 2004 to 2010. Inclusion criteria were: age less than 60 years, high physical activity, varus deformity and involvement of medical compartment of knee. Patients with obesity, smoking, patelofemoral pain, lateral compartment lesion, deformity degree more than 20 degree, extension limitation and range of motion less than 90 degree were excluded. The clinical and radiologic characteristics were measured before and after operation.Results: Fourteen patients were females. All of them were younger than 50 years, with mean (±SD 27.64 (±10.88. The mean (±SD of follow up time was 4.33 (±1.7. All the patients were satisfied with the results of operation. Tenderness and pain decreased in all of them. In all patients autologus bone graft were used, in 15 cases (42.5% casting and in the rest T.Buttress plate were used for fixation of fractures. In both groups of primary and double varus the International knee documentation committee (IKDC and modified Larson indices were improved after operation, but there was no significant difference between two groups.Conclusion: High tibial open wedge osteotomy can have satisfying results in clinical signs and symptoms of patients with primary medial joint degenerative osteoarthritis. This procedure also may correct the deformity and improves the radiologic parameters of the patients.

  1. Hydroelastic slamming of flexible wedges: Modeling and experiments from water entry to exit

    Science.gov (United States)

    Shams, Adel; Zhao, Sam; Porfiri, Maurizio

    2017-03-01

    Fluid-structure interactions during hull slamming are of great interest for the design of aircraft and marine vessels. The main objective of this paper is to establish a semi-analytical model to investigate the entire hydroelastic slamming of a wedge, from the entry to the exit phase. The structural dynamics is described through Euler-Bernoulli beam theory and the hydrodynamic loading is estimated using potential flow theory. A Galerkin method is used to obtain a reduced order modal model in closed-form, and a Newmark-type integration scheme is utilized to find an approximate solution. To benchmark the proposed semi-analytical solution, we experimentally investigate fluid-structure interactions through particle image velocimetry (PIV). PIV is used to estimate the velocity field, and the pressure is reconstructed by solving the incompressible Navier-Stokes equations from PIV data. Experimental results confirm that the flow physics and free-surface elevation during water exit are different from water entry. While water entry is characterized by positive values of the pressure field, with respect to the atmospheric pressure, the pressure field during water exit may be less than atmospheric. Experimental observations indicate that the location where the maximum pressure in the fluid is attained moves from the pile-up region to the keel, as the wedge reverses its motion from the entry to the exit stage. Comparing experimental results with semi-analytical findings, we observe that the model is successful in predicting the free-surface elevation and the overall distribution of the hydrodynamic loading on the wedge. These integrated experimental and theoretical analyses of water exit problems are expected to aid in the design of lightweight structures, which experience repeated slamming events during their operation.

  2. Peripheral Neuropathy and Agent Orange

    Science.gov (United States)

    ... Enter ZIP code here Enter ZIP code here Peripheral Neuropathy and Agent Orange VA presumes Veterans' early-onset ... 10 percent disabling by VA's rating regulations. About peripheral neuropathy Peripheral neuropathy is a condition of the peripheral ...

  3. Adopting wedge hepatic venography with CO2 during transjugular intrahepatic portosystemic shunt procedures

    International Nuclear Information System (INIS)

    Zhang Linpeng; Chen Songtao; Shi Xiulan

    2012-01-01

    Objective: To renovate angiography in identifying portal vein anatomy during transjugular intrahepatic portosystemic shunt (TIPS) procedures, saving the time of TIPS procedures, decreasing the risk of the complications of the post-procedure. Methods: The difference between the Wedge hepatic venography with Carbon Dioxide in 6 cases and Inferior Mesenteric artery angiography in 7 cases during TIPS procedures were compared in the identification of portal vein anatomy. The quality of images, their effects on the procedures, the complications and the recovery post-procedure were evaluated. Results: Using CO 2 , the portal veins were opacified in all 6 cases. TIPS procedures succeeded in all cases except 1 case because of poor coagulation function. Using Inferior Mesenteric artery angiography, the portal veins were opacified in all 7 cases. TIPS procedure succeeded in all cases except 1 case because of chronic portal occlusion. Puncture-site hematoma occurred in 1 case after TIPS procedure. Conclusion: Wedge hepatic venography with Carbon Dioxide is superior, safer and more convenient than Inferior Mesenteric Artery angiography in identifying portal vein anatomy during TIPS. (authors)

  4. Stem thrust prediction model for W-K-M double wedge parallel expanding gate valves

    Energy Technology Data Exchange (ETDEWEB)

    Eldiwany, B.; Alvarez, P.D. [Kalsi Engineering Inc., Sugar Land, TX (United States); Wolfe, K. [Electric Power Research Institute, Palo Alto, CA (United States)

    1996-12-01

    An analytical model for determining the required valve stem thrust during opening and closing strokes of W-K-M parallel expanding gate valves was developed as part of the EPRI Motor-Operated Valve Performance Prediction Methodology (EPRI MOV PPM) Program. The model was validated against measured stem thrust data obtained from in-situ testing of three W-K-M valves. Model predictions show favorable, bounding agreement with the measured data for valves with Stellite 6 hardfacing on the disks and seat rings for water flow in the preferred flow direction (gate downstream). The maximum required thrust to open and to close the valve (excluding wedging and unwedging forces) occurs at a slightly open position and not at the fully closed position. In the nonpreferred flow direction, the model shows that premature wedging can occur during {Delta}P closure strokes even when the coefficients of friction at different sliding surfaces are within the typical range. This paper summarizes the model description and comparison against test data.

  5. Stem thrust prediction model for W-K-M double wedge parallel expanding gate valves

    International Nuclear Information System (INIS)

    Eldiwany, B.; Alvarez, P.D.; Wolfe, K.

    1996-01-01

    An analytical model for determining the required valve stem thrust during opening and closing strokes of W-K-M parallel expanding gate valves was developed as part of the EPRI Motor-Operated Valve Performance Prediction Methodology (EPRI MOV PPM) Program. The model was validated against measured stem thrust data obtained from in-situ testing of three W-K-M valves. Model predictions show favorable, bounding agreement with the measured data for valves with Stellite 6 hardfacing on the disks and seat rings for water flow in the preferred flow direction (gate downstream). The maximum required thrust to open and to close the valve (excluding wedging and unwedging forces) occurs at a slightly open position and not at the fully closed position. In the nonpreferred flow direction, the model shows that premature wedging can occur during ΔP closure strokes even when the coefficients of friction at different sliding surfaces are within the typical range. This paper summarizes the model description and comparison against test data

  6. Soil carbon sequestration is a climate stabilization wedge: comments on Sommer and Bossio (2014).

    Science.gov (United States)

    Lassaletta, Luis; Aguilera, Eduardo

    2015-04-15

    Sommer and Bossio (2014) model the potential soil organic carbon (SOC) sequestration in agricultural soils (croplands and grasslands) during the next 87 years, concluding that this process cannot be considered as a climate stabilization wedge. We argue, however, that the amounts of SOC potentially sequestered in both scenarios (pessimistic and optimistic) fulfil the requirements for being considered as wedge because in both cases at least 25 GtC would be sequestered during the next 50 years. We consider that it is precisely in the near future, and meanwhile other solutions are developed, when this stabilization effort is most urgent even if after some decades the sequestration rate is significantly reduced. Indirect effects of SOC sequestration on mitigation could reinforce the potential of this solution. We conclude that the sequestration of organic carbon in agricultural soils as a climate change mitigation tool still deserves important attention for scientists, managers and policy makers. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Vascular access in neonatology: peripherally inserted central catheter and peripheral venous catheter

    Directory of Open Access Journals (Sweden)

    Marcia Lienemann

    2014-04-01

    The objective of this paper is to present aspects of peripherally inserted central catheter and peripheral venous catheter, highlighting important points in choosing the type of access. For the passage of peripherally inserted central catheter is previously performing specific course necessary, while the primary indication occurs when it is necessary to access the patient's stay for a long period of time. Whereas peripheral venipuncture is the most appropriate in cases of needing an IV line quickly and safely, for the administration of fluids, blood collection, blood transfusion and other.

  8. Higher-spin algebras, holography and flat space

    Energy Technology Data Exchange (ETDEWEB)

    Sleight, C. [Max-Planck-Institut für Physik (Werner-Heisenberg-Institut),Föhringer Ring 6, D-80805 Munich (Germany); Université Libre de Bruxelles and International Solvay Institutes,ULB-Campus Plaine CP231, 1050 Brussels (Belgium); Taronna, M. [Université Libre de Bruxelles and International Solvay Institutes,ULB-Campus Plaine CP231, 1050 Brussels (Belgium)

    2017-02-20

    In this article we study the higher-spin algebra behind the type-A cubic couplings recently extracted from the free O(N) model in generic dimensions, demonstrating that they coincide with the known structure constants for the unique higher-spin algebra in generic dimensions. This provides an explicit check of the holographic reconstruction and of the duality between higher-spin theories and the free O(N) model in generic dimensions, generalising the result of Giombi and Yin in AdS{sub 4}. For completeness, we also address the same problem in the flat space for the cubic couplings derived by Metsaev in 1991, which are recovered from the flat limit of the AdS type-A cubic couplings. We observe that both flat and AdS{sub 4} higher-spin Lorentz subalgebras coincide, hinting towards the existence of a full higher-spin symmetry behind the flat-space cubic couplings of Metsaev.

  9. Flat-port connectors

    KAUST Repository

    Alrashed, Mohammed

    2017-01-01

    and water resistant. It is unique in the way of using the outer surfaces of the device for the electrical connection between the ports. Flat-port design can allow the manufacture of extremely thin devices by eliminating the side ports slots that take a lot

  10. A developed wedge fixtures assisted high precision TEM samples pre-thinning method: Towards the batch lamella preparation

    Directory of Open Access Journals (Sweden)

    Dandan Wang

    2017-04-01

    Full Text Available Ion milling, wedge cutting or polishing, and focused ion beam (FIB milling are widely-used techniques for the transmission electron microscope (TEM sample preparation. Especially, the FIB milling provides a site-specific analysis, deposition, and ablation of materials in the micrometer and nanometer scale. However, the cost of FIB tools has been always a significant concern. Since it is inevitable to use the FIB technique, the improvement of efficiency is a key point. Traditional TEM sample preparation with FIB was routinely implemented on a single sample each time. Aiming at cost efficiency, a new pre-thinning technique for batch sample preparation was developed in this paper. The present proposal combines the sample preparation techniques with multi-samples thinning, cross-section scanning electron microscopy (SEM, wedge cutting, FIB and other sample pre-thinning techniques. The new pre-thinning technique is to prepare an edge TEM sample on a grinding and polishing fixture with a slant surface. The thickness of the wedges sample can be measured to 1∼2 μm under optical microscope. Therefore, this fixture is superior to the traditional optical method of estimating the membrane thickness. Moreover, by utilizing a multi-sample holding fixture, more samples can be pre-thinned simultaneously, which significantly improved the productivity of TEM sample preparation.

  11. Radiation monitor training program at Rocky Flats

    International Nuclear Information System (INIS)

    Medina, L.C.; Kittinger, W.D.; Vogel, R.M.

    The Rocky Flats Radiation Monitor Training Program is tailored to train new health physics personnel in the field of radiation monitoring. The purpose of the prescribed materials and media is to be consistent in training in all areas of Rocky Flats radiation monitoring job involvement

  12. Design, performance, and calibration of CMS hadron-barrel calorimeter wedges

    International Nuclear Information System (INIS)

    Abdullin, S.; Abramov, V.; Goncharov, P.; Khmelnikov, A.; Korablev, A.; Korneev, Y.; Krinitsyn, A.; Kryshkin, V.; Lukanin, V.; Pikalov, V.; Ryazanov, A.; Talov, V.; Turchanovich, L.; Volkov, A.; Acharya, B.; Banerjee, S.; Banerjee, S.; Chendvankar, S.; Dugad, S.; Kalmani, S.; Katta, S.; Mazumdar, K.; Mondal, N.; Nagaraj, P.; Patil, M.; Reddy, L.; Satyanarayana, B.; Sudhakar, K.; Verma, P.; Adams, M.; Burchesky, K.; Qian, W.; Akchurin, N.; Carrell, K.; Guemues, K.; Thomas, R.; Akgun, U.; Ayan, S.; Duru, F.; Merlo, J.P.; Mestvirishvili, A.; Miller, M.; Norbeck, E.; Olson, J.; Onel, Y.; Schmidt, I.; Anderson, E.W.; Hauptman, J.; Antchev, G.; Hazen, E.; Lawlor, C.; Machado, E.; Posch, C.; Rohlf, J.; Wu, S.X.; Aydin, S.; Dumanoglu, I.; Eskut, E.; Kayis-Topaksu, A.; Polatoz, A.; Onengut, G.; Ozdes-Koca, N.; Baarmand, M.; Ralich, R.; Vodopiyanov, I.; Baden, D.; Bard, R.; Eno, S.; Grassi, T.; Jarvis, C.; Kellogg, R.; Kunori, S.; Skuja, A.; Barnes, V.; Laasanen, A.; Pompos, A.; Bawa, H.; Beri, S.; Bhatnagar, V.; Kaur, M.; Kohli, J.; Kumar, A.; Singh, J.; Baiatian, G.; Sirunyan, A.; Bencze, G.; Vesztergombi, G.; Zalan, P.; Bodek, A.; Budd, H.; Chung, Y.; De Barbaro, P.; Haelen, T.; Camporesi, T.; Visser, T. de; Cankocak, K.; Cremaldi, L.; Reidy, J.; Sanders, D.A.; Cushman, P.; Sherwood, B.; Damgov, J.; Dimitrov, L.; Genchev, V.; Piperov, S.; Vankov, I.; Demianov, A.; Ershov, A.; Gribushin, A.; Kodolova, O.; Petrushanko, S.; Sarycheva, L.; Vardanyan, I.; Elias, J.; Elvira, D.; Freeman, J.; Green, D.; Los, S.; O'Dell, V.; Ronzhin, A.; Sergeyev, S.; Suzuki, I.; Vidal, R.; Whitmore, J.; Emeliantchik, I.; Massolov, V.; Shumeiko, N.; Stefanovich, R.; Fisher, W.; Tully, C.; Gavrilov, V.; Kaftanov, V.; Kisselevich, I.; Kolossov, V.; Krokhotin, A.; Kuleshov, S.; Stolin, V.; Ulyanov, A.; Gershtein, Y.; Golutvin, I.; Kalagin, V.; Kosarev, I.; Mescheryakov, G.; Smirnov, V.; Volodko, A.; Zarubin, A.; Grinev, B.; Lubinsky, V.; Senchishin, V.; Guelmez, E.; Hagopian, S.; Hagopian, V.; Johnson, K.; Heering, A.; Imboden, M.; Isiksal, E.; Karmgard, D.; Ruchti, R.; Kaya, M.; Lazic, D.; Levchuk, L.; Sorokin, P.; Litvintsev, D.; Litov, L.; Mans, J.; Ozkorucuklu, S.; Ozok, F.; Serin-Zeyrek, M.; Sever, R.; Zeyrek, M.; Paktinat, S.; Podrasky, V.; Sanzeni, C.; Winn, D.; Vlassov, E.

    2008-01-01

    Extensive measurements have been made with pions, electrons and muons on four production wedges of the compact muon solenoid (CMS) hadron barrel (HB) calorimeter in the H2 beam line at CERN with particle momenta varying from 20 to 300 GeV/c. The time structure of the events was measured with the full chain of preproduction front-end electronics running at 34 MHz. Moving-wire radioactive source data were also collected for all scintillator layers in the HB. The energy dependent time slewing effect was measured and tuned for optimal performance. (orig.)

  13. Design, performance, and calibration of CMS hadron-barrel calorimeter wedges

    Energy Technology Data Exchange (ETDEWEB)

    Abdullin, S. [Fermi National Accelerator Lab., Batavia, IL (United States)]|[Univ. of Maryland, College Park, MD (United States); Abramov, V.; Goncharov, P.; Khmelnikov, A.; Korablev, A.; Korneev, Y.; Krinitsyn, A.; Kryshkin, V.; Lukanin, V.; Pikalov, V.; Ryazanov, A.; Talov, V.; Turchanovich, L.; Volkov, A. [IHEP, Protvino (Russian Federation); Acharya, B.; Banerjee, S.; Banerjee, S.; Chendvankar, S.; Dugad, S.; Kalmani, S.; Katta, S.; Mazumdar, K.; Mondal, N.; Nagaraj, P.; Patil, M.; Reddy, L.; Satyanarayana, B.; Sudhakar, K.; Verma, P. [Tata Inst. of Fundamental Research, Mumbai (India); Adams, M.; Burchesky, K.; Qian, W. [Univ. of Illinois at Chicago, Chicago, IL (United States); Akchurin, N.; Carrell, K.; Guemues, K.; Thomas, R. [Texas Tech Univ., Dept. of Physics, Lubbock, TX (United States); Akgun, U.; Ayan, S.; Duru, F.; Merlo, J.P.; Mestvirishvili, A.; Miller, M.; Norbeck, E.; Olson, J.; Onel, Y.; Schmidt, I. [Univ. of Iowa, Iowa City, IA (United States); Anderson, E.W.; Hauptman, J. [Iowa State Univ., Ames, IA (United States); Antchev, G.; Hazen, E.; Lawlor, C.; Machado, E.; Posch, C.; Rohlf, J.; Wu, S.X. [Boston Univ., Boston, MA (United States); Aydin, S.; Dumanoglu, I.; Eskut, E.; Kayis-Topaksu, A.; Polatoz, A.; Onengut, G.; Ozdes-Koca, N. [Cukurova Univ., Adana (Turkey); Baarmand, M.; Ralich, R.; Vodopiyanov, I. [Florida Inst. of Technology, Melbourne, FL (United States); Baden, D.; Bard, R.; Eno, S.; Grassi, T.; Jarvis, C.; Kellogg, R.; Kunori, S.; Skuja, A. [Univ. of Maryland, College Park, MD (United States); Barnes, V.; Laasanen, A.; Pompos, A. [Purdue Univ., West Lafayette, IN (United States); Bawa, H.; Beri, S.; Bhatnagar, V.; Kaur, M.; Kohli, J.; Kumar, A.; Singh, J. [Panjab Univ., Chandigarh (India); Baiatian, G.; Sirunyan, A. [Yerevan Physics Inst., Yerevan (Armenia); Bencze, G.; Vesztergombi, G.; Zalan, P. [KFKI-RMKI, Research Inst. for Particle and Nuclear Physics, Budapest (Hungary)] [and others

    2008-05-15

    Extensive measurements have been made with pions, electrons and muons on four production wedges of the compact muon solenoid (CMS) hadron barrel (HB) calorimeter in the H2 beam line at CERN with particle momenta varying from 20 to 300 GeV/c. The time structure of the events was measured with the full chain of preproduction front-end electronics running at 34 MHz. Moving-wire radioactive source data were also collected for all scintillator layers in the HB. The energy dependent time slewing effect was measured and tuned for optimal performance. (orig.)

  14. Wedge Splitting Test on Fracture Behaviour of Fiber Reinforced and Regular High Performance Concretes

    DEFF Research Database (Denmark)

    Hodicky, Kamil; Hulin, Thomas; Schmidt, Jacob Wittrup

    2013-01-01

    The fracture behaviour of three fiber reinforced and regular High Performance Concretes (HPC) is presented in this paper. Two mixes are based on optimization of HPC whereas the third mix was a commercial mix developed by CONTEC ApS (Denmark). The wedge splitting test setup with 48 cubical specimens...

  15. Tax wedge on labour income in Croatia and the European Union : Preface to the special issue of Financial Theory and Practice

    Directory of Open Access Journals (Sweden)

    Ivica Urban

    2016-06-01

    Full Text Available This article is a preface to a special issue of Financial Theory and Practice, which is devoted to the comparison of tax wedge on labour income in Croatia and other EU countries. The articles in this issue have arisen from the students’ research project, undertaken in 2015. This Preface outlines the motivation behind the research project, explains the most important methodological issues, and reviews the literature on the measurement of tax wedge in Croatia.

  16. Flat connection, conformal field theory and quantum group

    International Nuclear Information System (INIS)

    Kato, Mitsuhiro.

    1989-07-01

    General framework of linear first order differential equation for four-point conformal block is studied by using flat connection. Integrability and SL 2 invariance restrict possible form of flat connection. Under a special ansatz classical Yang-Baxter equation appears as an integrability condition and the WZW model turns to be unique conformal field theory in that case. Monodromy property of conformal block can be easily determined by the flat connection. 11 refs

  17. Sedimentation of Jurassic fan-delta wedges in the Xiahuayuan basin reflecting thrust-fault movements of the western Yanshan fold-and-thrust belt, China

    Science.gov (United States)

    Lin, Chengfa; Liu, Shaofeng; Zhuang, Qitian; Steel, Ronald J.

    2018-06-01

    Mesozoic thrusting within the Yanshan fold-and-thrust belt of North China resulted in a series of fault-bounded intramontane basins whose infill and evolution remain poorly understood. In particular, the bounding faults and adjacent sediment accumulations along the western segments of the belt are almost unstudied. A sedimentological and provenance analysis of the Lower Jurassic Xiahuayuan Formation and the Upper Jurassic Jiulongshan Formation have been mapped to show two distinctive clastic wedges: an early Jurassic wedge representing a mass-flow-dominated, Gilbert-type fan delta with a classic tripartite architecture, and an late Jurassic shoal-water fan delta without steeply inclined strata. The basinward migration of the fan-delta wedges, together with the analysis of their conglomerate clast compositions, paleocurrent data and detrital zircon U-Pb age spectra, strongly suggest that the northern-bounding Xuanhuan thrust fault controlled their growth during accumulation of the Jiulongshan Formation. Previous studies have suggested that the fan-delta wedge of the Xiahuayuan Formation was also syntectonic, related to movement on the Xuanhua thrust fault. Two stages of thrusting therefore exerted an influence on the formation and evolution of the Xiahuayuan basin during the early-late Jurassic.

  18. Wedge cells during regeneration of juvenile and adult feathers and their role in carving out the branching pattern of barbs.

    Science.gov (United States)

    Alibardi, Lorenzo

    2007-01-01

    The present ultrastructural study on regenerating feathers emphasizes the role of supportive cells in determining the branching pattern of barbs. Supportive cells are localized among developing barb and barbule cells, in marginal plates, and underneath the feather sheath, and their differentiative fate, in general, is a form of lipid degeneration. The Latter process determines the carving out of barb branching in both downfeathers and pennaceous feathers. In the latter feathers, some supportive cells (barb vane cells and cylindrical cells of marginal plates) degenerate within each barb ridge leaving separate barbules. Other supportive cells, here termed wedge cells, form columns of cornified material that merge into elongated corneous scaffolds localized among barbs and the rachis. This previously undescribed form of cornification of supportive cells derives from the aggregation of periderm and dense granules present in wedge cells. The latter cells give origin to a corneous material different from feather keratin that may initially sustain the early and soft barbules. After barbules are cornified the supportive cells scaffolds are eventually sloughed as the sheath breaks allowing the new feather to open up and form a planar vane. The corneous material of wedge cells may also contribute to molding of the overlapped nodes of barbule cells that form lateral spines or hooklets in mature barbules. Eventually, the disappearance of wedge cell scaffolding determines the regular spacing of barbs attached to the rachis in order to form a close vane.

  19. Modification of the cranial closing wedge ostectomy technique for the treatment of canine cruciate disease. Description and comparison with standard technique.

    Science.gov (United States)

    Wallace, A M; Addison, E S; Smith, B A; Radke, H; Hobbs, S J

    2011-01-01

    To describe a modification of the cranial closing wedge ostectomy (CCWO) technique and to compare its efficacy to the standard technique on cadaveric specimens. The standard and modified CCWO technique were applied to eight pairs of cadaveric tibiae. The following parameters were compared following the ostectomy: degrees of plateau levelling achieved (degrees), tibial long axis shift (degrees), reduction in tibial length (mm), area of bone wedge removed (cm²), and the area of proximal fragment (cm²). The size of the removed wedge of bone and the reduction in tibial length were significantly less with the modified CCWO technique. The modified CCWO has two main advantages. Firstly a smaller wedge is removed, allowing a greater preservation of bone stock in the proximal tibia, which is advantageous for implant placement. Secondly, the tibia is shortened to a lesser degree, which might reduce the risk of recurvatum, fibular fracture and patella desmitis. These factors are particularly propitious for the application of this technique to Terrier breeds with excessive tibial plateau angle, where large angular corrections are required. The modified CCWO is equally effective for plateau levelling and results in an equivalent tibial long-axis shift. A disadvantage with the modified technique is that not all of the cross sectional area of the distal fragment contributes to load sharing at the osteotomy.

  20. Integrated Weed Control for Land Stewardship at Legacy Management's Rocky Flats Site in Colorado - 13086

    International Nuclear Information System (INIS)

    Nelson, Jody K.

    2013-01-01

    Land stewardship is one of nine sustainability programs in the U.S. Department of Energy's Environmental Management System. Land stewardship includes maintaining and improving ecosystem health. At the Rocky Flats Site near Westminster, Colorado, land stewardship is an integral component of the Office of Legacy Management's post-closure monitoring and management at the site. Nearly 263 hectares (650 acres) were disturbed and re-vegetated during site cleanup and closure operations. Proactive management of revegetation areas is critical to the successful reestablishment of native grasslands, wetlands, and riparian communities. The undisturbed native plant communities that occur at the site also require active management to maintain the high-quality wetlands and other habitats that are home to numerous species of birds and other wildlife such as elk and deer, rare plant communities, and the federally listed threatened Preble's meadow jumping mouse. Over the past several decades, an increase of Noxious weeds has impacted much of Colorado's Front Range. As a result, weed control is a key component of the land stewardship program at Rocky Flats. Thirty-three species of state-listed Noxious weeds are known to occur in the Central and Peripheral Operable Units at Rocky Flats, along with another five species that are considered invasive at the site. Early detection and rapid response to control new invasive species is crucial to the program. An integrated weed control/vegetation management approach is key to maintaining healthy, sustainable plant communities that are able to resist Noxious weed invasions. Weed mapping, field surveys, and field-staff training sessions (to learn how to identify new potential problem species) are conducted to help detect and prevent new weed problems. The integrated approach at Rocky Flats includes administrative and cultural techniques (prevention), mechanical controls, biological controls, and chemical controls. Several species of biocontrol

  1. Chaotic inflation in models with flat directions

    International Nuclear Information System (INIS)

    Graziani, F.; Olive, K.

    1989-01-01

    We consider the chaotic inflationary scenario in models with flat directions. We find that unless the scalars along the flat directions have vacuum expectation values p or 10 14 M p 15 M p depending on the expectation values of the chaotic inflator, Ψ, one or two or more periods of inflation occur but with a resulting energy density perturbation δρ/ρ ≅ 10 -16 , far too small to be of any consequence for galaxy formation. Even with p only limited initial values of ≅ (3-200) M p result in inflation with reasonable density perturbations. Thus chaotic inflation in models with flat directions require rather special initial conditions. (orig.)

  2. Magnetized and Flat Beam Experiment at FAST

    Energy Technology Data Exchange (ETDEWEB)

    Halavanau, A. [Fermilab; Hyun, J. [Sokendai, Tsukuba; Mihalcea, D. [NIU, DeKalb; Piot, P. [NICADD, DeKalb; Sen, T. [Fermilab; Thangaraj, C. [Fermilab

    2017-05-22

    A photocathode, immersed in solenoidal magnetic field, can produce canonical-angular-momentum (CAM) dominated or “magnetized” electron beams. Such beams have an application in electron cooling of hadron beams and can also be uncoupled to yield asymmetric-emittance (“flat”) beams. In the present paper we explore the possibilities of the flat beam generation at Fermilab’s Accelerator Science and Technology (FAST) facility. We present optimization of the beam flatness and four-dimensional transverse emittance and investigate the mapping and its limitations of the produced eigen-emittances to conventional emittances using a skew-quadrupole channel. Possible application of flat beams at the FAST facility are also discussed.

  3. Drug-induced peripheral neuropathy

    DEFF Research Database (Denmark)

    Vilholm, Ole Jakob; Christensen, Alex Alban; Zedan, Ahmed

    2014-01-01

    Peripheral neuropathy can be caused by medication, and various descriptions have been applied for this condition. In this MiniReview, the term 'drug-induced peripheral neuropathy' (DIPN) is used with the suggested definition: Damage to nerves of the peripheral nervous system caused by a chemical...... substance used in the treatment, cure, prevention or diagnosis of a disease. Optic neuropathy is included in this definition. A distinction between DIPN and other aetiologies of peripheral neuropathy is often quite difficult and thus, the aim of this MiniReview is to discuss the major agents associated...

  4. On maximal surfaces in asymptotically flat space-times

    International Nuclear Information System (INIS)

    Bartnik, R.; Chrusciel, P.T.; O Murchadha, N.

    1990-01-01

    Existence of maximal and 'almost maximal' hypersurfaces in asymptotically flat space-times is established under boundary conditions weaker than those considered previously. We show in particular that every vacuum evolution of asymptotically flat data for Einstein equations can be foliated by slices maximal outside a spatially compact set and that every (strictly) stationary asymptotically flat space-time can be foliated by maximal hypersurfaces. Amongst other uniqueness results, we show that maximal hypersurface can be used to 'partially fix' an asymptotic Poincare group. (orig.)

  5. Choice of Surgical Procedure for Patients With Non-Small-Cell Lung Cancer ≤ 1 cm or > 1 to 2 cm Among Lobectomy, Segmentectomy, and Wedge Resection

    DEFF Research Database (Denmark)

    Dai, Chenyang; Shen, Jianfei; Ren, Yijiu

    2016-01-01

    PURPOSE: According to the lung cancer staging project, T1a (≤ 2 cm) non-small-cell lung cancer (NSCLC) should be additionally classified into ≤ 1 cm and > 1 to 2 cm groups. This study aimed to investigate the surgical procedure for NSCLC ≤ 1 cm and > 1 to 2 cm. METHODS: We identified 15...... multiple prognostic factors. RESULTS: OS and LCSS favored lobectomy compared with segmentectomy or wedge resection in patients with NSCLC ≤ 1 cm and > 1 to 2 cm. Multivariable analysis showed that segmentectomy and wedge resection were independently associated with poorer OS and LCSS than lobectomy...... for NSCLC ≤ 1 cm and > 1 to 2 cm. With sublobar resection, lower OS and LCSS emerged for NSCLC > 1 to 2 cm after wedge resection, whereas similar survivals were observed for NSCLC ≤ 1 cm. Multivariable analyses showed that wedge resection is an independent risk factor of survival for NSCLC > 1 to 2 cm...

  6. Array elements for a DBS flat-plate antenna

    Science.gov (United States)

    Maddocks, M. C. D.

    1988-07-01

    The introduction of a direct broadcast by satellite (DBS) television service requires suitable receiving antennas to be available. An alternative to the parabolic dish antenna is a flat-plate antenna. The overall design of a circularly-polarized flat-plate antenna which can be mounted flat on the wall of a building has been considered in a companion Report. In this Report various types of elements are investigated and their advantages and disadvantages discussed. The most suitable element for use in a flat-plate array is identified as a linearly-polarized folded-dipole element; its performance is reported here. Linearly-polarized elements are found to perform better than circularly-polarized elements and could be used with a polarization converter to receive the circularly-polarized radiation that would be transmitted by DBS.

  7. Numerical study and pilot evaluation of experimental data measured on specimen loaded by bending and wedge splitting forces

    Directory of Open Access Journals (Sweden)

    S. Seitl

    2017-01-01

    Full Text Available The fracture mechanical properties of silicate based materials are determined from various fracture mechanicals tests, e.g. three- or four- point bending test, wedge splitting test, modified compact tension test etc. For evaluation of the parameters, knowledge about the calibration and compliance functions is required. Therefore, in this paper, the compliance and calibration curves for a novel test geometry based on combination of the wedge splitting test and three-point bending test are introduced. These selected variants exhibit significantly various stress state conditions at the crack tip, or, more generally, in the whole specimen ligament. The calibration and compliance curves are compared and used for evaluation of the data from pilot experimental measurement.

  8. Flat-screen detector systems in skeletal radiology

    International Nuclear Information System (INIS)

    Grampp, S.; Czerny, C.; Krestan, C.; Henk, C.; Heiner, L.; Imhof, H.

    2003-01-01

    Implementation of flat-panel detectors and digital integration of the technique instead of the use of conventional radiographs leads to a shortening of the work process. With flat-panel technology the image production process is shortened by more than 30%. Major advantages in the implementation of integrated RIS, PACS and flat-panel detector system are increases in quality because most mistakes in picture labeling can be avoided, easier handling without the need for cassettes, and the possibility of image post-processing. The diagnostic quality of the images in the field of musculoskeletal radiology is, in comparison to conventional radiographs, at least adequate and in most cases markedly improved with a marked reduction in radiation exposure of around 30-50%. With respect to the numerous advantages of the digital techniques and especially flat-panel technology there is a very high likelihood that conventional radiographs will be substituted in the coming years, even though the cost of the new technology is currently significantly higher compared to conventional systems. (orig.) [de

  9. Flat deformation theorem and symmetries in spacetime

    International Nuclear Information System (INIS)

    Llosa, Josep; Carot, Jaume

    2009-01-01

    The flat deformation theorem states that given a semi-Riemannian analytic metric g on a manifold, locally there always exists a two-form F, a scalar function c, and an arbitrarily prescribed scalar constraint depending on the point x of the manifold and on F and c, say Ψ(c, F, x) = 0, such that the deformed metric η = cg - εF 2 is semi-Riemannian and flat. In this paper we first show that the above result implies that every (Lorentzian analytic) metric g may be written in the extended Kerr-Schild form, namely η ab := ag ab - 2bk (a l b) where η is flat and k a , l a are two null covectors such that k a l a = -1; next we show how the symmetries of g are connected to those of η, more precisely; we show that if the original metric g admits a conformal Killing vector (including Killing vectors and homotheties), then the deformation may be carried out in a way such that the flat deformed metric η 'inherits' that symmetry.

  10. Transumbilical Thoracoscopy Versus Conventional Thoracoscopy for Lung Wedge Resection: Safety and Efficacy in a Live Canine Model.

    Science.gov (United States)

    Chen, Tzu-Ping; Yen-Chu; Wu, Yi-Cheng; Yeh, Chi-Ju; Liu, Chien-Ying; Hsieh, Ming-Ju; Yuan, Hsu-Chia; Ko, Po-Jen; Liu, Yun-Hen

    2015-12-01

    Transumbilical single-port surgery has been associated with less postoperative pain and offers better cosmetic outcomes than conventional 3-port laparoscopic surgery. This study compares the safety and efficacy of transumbilical thoracoscopy and conventional thoracoscopy for lung wedge resection. The animals (n = 16) were randomly assigned to the transumbilical thoracoscopic approach group (n = 8) or conventional thoracoscopic approach group (n = 8). Transumbilical lung resection was performed via an umbilical incision and a diaphragmatic incision. In the conventional thoracoscopic group, lung resection was completed through a thoracic incision. For both procedures, we compared the surgical outcomes, for example, operating time and operative complications; physiologic parameters, for example, respiratory rate and body temperature; inflammatory parameters, for example, white blood cell count; and pulmonary parameters, for example, arterial blood gas levels. The animals were euthanized 2 weeks after the surgery for gross and histologic evaluations. The lung wedge resection was successfully performed in all animals. There was no significant difference in the mean operating times or complications between the transumbilical and the conventional thoracoscopic approach groups. With regard to the physiologic impact of the surgeries, the transumbilical approach was associated with significant elevations in body temperature on postoperative day 1, when compared with the standard thoracoscopic approach. This study suggests that both approaches for performing lung wedge resection were comparable in efficacy and postoperative complications. © The Author(s) 2014.

  11. Flat Panel PMT: advances in position sensitive photodetection

    International Nuclear Information System (INIS)

    Pani, R.; Pellegrini, R.; Trotta, C.; Cinti, M.N.; Bennati, P.; Trotta, G.; Iurlaro, G.; Montani, L.; Ridolfi, S.; Cusanno, F.; Garibaldi, F.

    2003-01-01

    Over the last ten years there was being a strong advancement in photodetection. Different application fields are involved in their use in particular high energy physics, astrophysics and nuclear medicine. They usually work by coupling a scintillation crystal and more recent scintillation arrays with pixel size as small as 0.5 mm. PSPMT represents today the most ready technology for photodetection with large detection areas and very high spatial resolution. Flat panel PMT represents the last technological advancement. Its dimension is 50x50 mm 2 with a narrow peripheral dead zone (0.5 mm final goal). Its compactness allow to assemble different modules closely packed, achieving large detection areas with an effective active area of 97%. In this paper we analyze the imaging performances of PSPMT by coupling two scintillation arrays and by light spot scanning of photocathode to evaluate the linearity position response, spatial resolution and uniformity gain response as a function of light distribution spread and the number of photoelectrons generated on photocathode. The results point out a very narrow PMT intrinsic charge spread and low cross-talk between anodes. Energy resolution and spatial resolution show a good linearity with DRF variation. An unexpected intra-anode gain variation is carried out. In this paper we present the results obtained with this PSPMT regarding imaging performances principally addressed to nuclear medicine application

  12. Formation of forearc basins by collision between seamounts and accretionary wedges: an example from the New Hebrides subduction zone

    Science.gov (United States)

    Collot, J.-Y.; Fisher, M.A.

    1989-01-01

    Seabeam data reveal two deep subcircular reentrants in the lower arc slope of the New Hebrides island arc that may illustrate two stages in the development of a novel type of forearc basin. The Malekula reentrant lies just south of the partly subducted Bougainville seamount. This proximity, as well as the similarity in morphology between the reentrant and an indentation in the lower arc slope off Japan, suggests that the Malekula reentrant formed by the collision of a seamount with the arc. An arcuate fold-thrust belt has formed across the mouth of the reentrant, forming the toe of a new accretionary wedge. The Efate reentrant may show the next stage in basin development. This reentrant lies landward of a lower-slope ridge that may have begun to form as an arcuate fold-thrust belt across the mouth of a reentrant. This belt may have grown by continued accretion at the toe of the wedge, by underplating beneath the reentrant, and by trapping of sediment shed from the island arc. These processes could result in a roughly circular forearc basin. Basins that may have formed by seamount collision lie within the accretionary wedge adjacent to the Aleutian trenches. -Authors

  13. New edge-centered photonic square lattices with flat bands

    Science.gov (United States)

    Zhang, Da; Zhang, Yiqi; Zhong, Hua; Li, Changbiao; Zhang, Zhaoyang; Zhang, Yanpeng; Belić, Milivoj R.

    2017-07-01

    We report a new class of edge-centered photonic square lattices with multiple flat bands, and consider in detail two examples: the Lieb-5 and Lieb-7 lattices. In these lattices, there are 5 and 7 sites in the unit cell and in general, the number is restricted to odd integers. The number of flat bands m in the new Lieb lattices is related to the number of sites N in the unit cell by a simple formula m =(N - 1) / 2. The flat bands reported here are independent of the pseudomagnetic field. The properties of lattices with even and odd number of flat bands are different. We consider the localization of light in such Lieb lattices. If the input beam excites the flat-band mode, it will not diffract during propagation, owing to the strong mode localization. In the Lieb-7 lattice, the beam will also oscillate during propagation and still not diffract. The period of oscillation is determined by the energy difference between the two flat bands. This study provides a new platform for investigating light trapping, photonic topological insulators, and pseudospin-mediated vortex generation.

  14. Flexible flat feet in children: a real problem?

    Science.gov (United States)

    García-Rodríguez, A; Martín-Jiménez, F; Carnero-Varo, M; Gómez-Gracia, E; Gómez-Aracena, J; Fernández-Crehuet, J

    1999-06-01

    To estimate the prevalence of flexible flat feet in the provincial population of 4- to 13-year-old schoolchildren and the incidence of treatments considered unnecessary. Province of Málaga, Spain. We examined and graded by severity a sample of 1181 pupils taken from a total population of 198 858 primary schoolchildren (CI: 95%; margin of error: 5%). The sample group was separated into three 2-year age groups: 4 and 5 years, 8 and 9 years, and 12 and 13 years. The plantar footprint was classified according to Denis1 into three grades of flat feet: grade 1 in which support of the lateral edge of the foot is half that of the metatarsal support; grade 2 in which the support of the central zone and forefoot are equal; and grade 3 in which the support in the central zone of the foot is greater than the width of the metatarsal support. The statistical analysis for the evaluation of the differences between the groups was performed with Student's t and chi2 tests as appropriate. The prevalence of flat feet was 2.7%. Of the 1181 children sampled, 168 children (14.2%) were receiving orthopedic treatment, but only 2.7% had diagnostic criteria of flat feet. When we inspected the sample, we found that a number of children were being treated for flat feet with boots and arch supports. Most of them did not have a flat plantar footprint according to the criteria that we used for this work. Furthermore, in the group of children that we diagnosed as having flat feet, only 28.1% were being treated. We found no significant differences between the number of children receiving orthopedic treatments and the presence or absence of a flat plantar footprint. Children who were overweight in the 4- and 5-year-old group showed an increased prevalence for flat feet as diagnosed by us. The data suggest that an excessive number of orthopedic treatments had been prescribed in the province. When extrapolated to the 1997 population of schoolchildren within the age groups studied the figures

  15. Thermal-hydraulic characteristics of double flat core HCLWR

    International Nuclear Information System (INIS)

    Sugimoto, Jun; Iwamura, Takamichi; Okubo, Tsutomu; Murao, Yoshio

    1989-02-01

    A thermal-hydraulic characteristics of double flat core high conversion light water reactor (HCLWR) is described. The concept of flat core proposed by Ishiguro et al. is to achieve negative void reactivity coefficient in tight lattice core, and at the same time, high conversion ratio and high burnup can be obtainable. The proposed double flat core HCLWR, based on these physical advantages and the consideration of safety assurance, aims at efficient use of the pressure vessel space to produce comparable thermal output as current 3-loop PWRs. The present work revealed the following items concerning the thermalhydraulic feasibility of the double flat core HCLWR: (1) Main thermal-hydraulic parameters of the plant can be almost the same as current PWRs, showing the use of PWR standard components without major modifications except in core region. (2) Heat removal from the fuel rod in a steady operational condition has enough margin to the critical heat flux (CHF) limit, which is evaluated with the existing CHF correlations. (3) The calculation by REFLA code shows that the maximum cladding temperature in LOCA-reflood is estimated to be far lower than the licensing criteria. It is therefore considered that the proposed double flat core HCLWR is feasible from the point of thermal-hydraulics. Since the available data base has certain applicational limit to the very short core as the present double flat core HCLWR, further detailed assessment is required. (author)

  16. ACS/WFC Sky Flats from Frontier Fields Imaging

    Science.gov (United States)

    Mack, J.; Lucas, R. A.; Grogin, N. A.; Bohlin, R. C.; Koekemoer, A. M.

    2018-04-01

    Parallel imaging data from the HST Frontier Fields campaign (Lotz et al. 2017) have been used to compute sky flats for the ACS/WFC detector in order to verify the accuracy of the current set of flat field reference files. By masking sources and then co-adding many deep frames, the F606W and F814W filters have enough combined background signal that from Poisson statistics are efficiency tracks the thickness of the two WFC chips. Observations of blue and red calibration standards measured at various positions on the detector (Bohlin et al. 2017) confirm the fidelity of the F814W flat, with aperture photometry consistent to 1% across the FOV, regardless of spectral type. At bluer wavelengths, the total sky background is substantially lower, and the F435W sky flat shows a combination of both flat errors and detector artifacts. Aperture photometry of the red standard star shows a maximum deviation of 1.4% across the array in this filter. Larger residuals up to 2.5% are found for the blue standard, suggesting that the spatial sensitivity in F435W depends on spectral type.

  17. Extracting flat-field images from scene-based image sequences using phase correlation

    Energy Technology Data Exchange (ETDEWEB)

    Caron, James N., E-mail: Caron@RSImd.com [Research Support Instruments, 4325-B Forbes Boulevard, Lanham, Maryland 20706 (United States); Montes, Marcos J. [Naval Research Laboratory, Code 7231, 4555 Overlook Avenue, SW, Washington, DC 20375 (United States); Obermark, Jerome L. [Naval Research Laboratory, Code 8231, 4555 Overlook Avenue, SW, Washington, DC 20375 (United States)

    2016-06-15

    Flat-field image processing is an essential step in producing high-quality and radiometrically calibrated images. Flat-fielding corrects for variations in the gain of focal plane array electronics and unequal illumination from the system optics. Typically, a flat-field image is captured by imaging a radiometrically uniform surface. The flat-field image is normalized and removed from the images. There are circumstances, such as with remote sensing, where a flat-field image cannot be acquired in this manner. For these cases, we developed a phase-correlation method that allows the extraction of an effective flat-field image from a sequence of scene-based displaced images. The method uses sub-pixel phase correlation image registration to align the sequence to estimate the static scene. The scene is removed from sequence producing a sequence of misaligned flat-field images. An average flat-field image is derived from the realigned flat-field sequence.

  18. Numerical study on flow rate limitation of open capillary channel flow through a wedge

    Directory of Open Access Journals (Sweden)

    Ting-Ting Zhang

    2016-04-01

    Full Text Available The flow characteristics of slender-column flow in wedge-shaped channel under microgravity condition are investigated in this work. The one-dimensional theoretical model is applied to predict the critical flow rate and surface contour of stable flow. However, the one-dimensional model overestimates the critical flow rate for not considering the extra pressure loss. Then, we develop a three-dimensional simulation method with OpenFOAM, a computational fluid dynamics tool, to simulate various phenomena in wedge channels with different lengths. The numerical results are verified with the capillary channel flow experimental data on the International Space Station. We find that the three-dimensional simulation perfectly predicts the critical flow rates and surface contours under various flow conditions. Meanwhile, the general behaviors in subcritical, critical, and supercritical flow are studied in three-dimensional simulation considering variations of flow rate and open channel length. The numerical techniques for three-dimensional simulation is validated for a wide range of configurations and is hopeful to provide valuable guidance for capillary channel flow experiment and efficient liquid management in space.

  19. Medical Devices; Obstetrical and Gynecological Devices; Classification of the Pressure Wedge for the Reduction of Cesarean Delivery. Final order.

    Science.gov (United States)

    2017-12-28

    The Food and Drug Administration (FDA or we) is classifying the pressure wedge for the reduction of cesarean delivery into class II (special controls). The special controls that apply to the device type are identified in this order and will be part of the codified language for the pressure wedge for the reduction of cesarean delivery's classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.

  20. Clarification of Institutional Controls at the Rocky Flats Site Central Operable Unit and Implementation of the Soil Disturbance Review Plan - 13053

    Energy Technology Data Exchange (ETDEWEB)

    DiSalvo, Rick [Stoller LMS Team, 11025 Dover St, Suite 1000, Westminster, CO 80021 (United States); Surovchak, Scott [U.S. Department of Energy, Office of Legacy Management, 11025 Dover St, Suite 1000, Westminster, CO 80021 (United States); Spreng, Carl [Colorado Department of Public Health and Environment, 4300 Cherry Creek Dr. S, Denver, CO 80246-1530 (United States); Moritz, Vera [U.S. Environmental Protection Agency, Region 8, 1595 Wynkoop St., Denver, CO 80202-1129 (United States)

    2013-07-01

    Cleanup and closure of DOE's Rocky Flats Site in Colorado, which was placed on the CERCLA National Priority List in 1989, was accomplished under CERCLA, RCRA, and the Colorado Hazardous Waste Act (CHWA). The physical cleanup work was completed in late 2005 and all buildings and other structures that composed the Rocky Flats industrial complex were removed from the surface, but remnants remain in the subsurface. Other remaining features include two landfills closed in place with covers, four groundwater treatment systems, and surface water and groundwater monitoring systems. Under the 2006 Corrective Action Decision/Record of Decision for Rocky Flats Plant (US DOE) Peripheral Operable Unit and the Central Operable Unit (CAD/ROD), the response actions selected for the Central Operable Unit (OU) are institutional controls (ICs), physical controls, and continued monitoring and maintenance. The objectives of these ICs were to prevent unacceptable exposure to remaining subsurface contamination and to prevent contaminants from mobilizing to surface water and to prevent interfering with the proper functioning of the engineered components of the remedy. An amendment in 2011 of the 2006 CAD/ROD clarified the ICs to prevent misinterpretation that would prohibit work to manage and maintain the Central OU property. The 2011 amendment incorporated a protocol for a Soil Disturbance Review Plan for work subject to ICs that requires approval from the State and public notification by DOE prior to conducting approved soil-disturbing work. (authors)

  1. Open wedge metatarsal osteotomy versus crescentic osteotomy to correct severe hallux valgus deformity - A prospective comparative study.

    Science.gov (United States)

    Wester, Jens Ulrik; Hamborg-Petersen, Ellen; Herold, Niels; Hansen, Palle Bo; Froekjaer, Johnny

    2016-03-01

    Different techniques of proximal osteotomies have been introduced to correct severe hallux valgus. The open wedge osteotomy is a newly introduced method for proximal osteotomy. The aim of this prospective randomized study was to compare the radiological and clinical results after operation for severe hallux valgus, comparing the open wedge osteotomy to the crescentic osteotomy which is our traditional treatment. Forty-five patients with severe hallux valgus (hallux valgus angle >35̊, and intermetatarsal angle >15̊) were included in this study. The treatment was proximal open wedge osteotomy and fixation with plate (Hemax), group 1, or operation with proximal crescentic osteotomy and fixation with a 3mm cannulated screw, group 2. The mean age was 52 years (19-71). Forty-one females and four males were included. Clinical and radiological follow-ups were performed 4 and 12 months after the operation. In group 1 the hallux valgus angle decreased from 39.0̊ to 24.1̊ after 4 months and 27.9̊ after 12 months. In group 2 the angle decreased from 38.3̊ to 21.4̊ after 4 months and 27.0̊ after 12 months. The intermetatarsal angle in group 1 was 19.0̊ preoperatively, 11.6̊ after 4 months and 12.6̊ after 12 months. In group 2 the mean intermetatarsal angle was 18.9̊ preoperatively, 12.0̊ after 4 months and 12.6̊ after 12 months. The AOFAS score improved from 59.3 to 81.5 in group 1 and from 61.8 to 84.8 in group 2 respectively measured 12 months postoperatively. The relative length of the 1 metatarsal compared to 2 metatarsal bone was 0.88 and 0.87 preoperatively and 0.88 and 0.86 for group 1 and 2 respectively measured after 12 months. Crescentic osteotomy and open wedge osteotomy improve AOFAS score and VAS scores on patients operated with severe hallux valgus. No significant difference was found in the two groups looking at the postoperative improvement of HVA and IMA measured 4 and 12 months postoperatively. The postoperative VAS score and AOFAS score were

  2. Radiochromic film calibration wedge EBT2 using virtual fields; Calibracion de peliculas radiocromicos EBT2 mediante campos con cunas virtuales

    Energy Technology Data Exchange (ETDEWEB)

    Perez, M. A.; Macias, J.; Merchan, M. A.; Campo, J. L.; Moreno, J. C.; Terron, J. A.; Miras, H.; Ortiz, M.; Arrans, R.; Ortiz, A.; Fernandez, D.

    2011-07-01

    EBT2 film dosimetry after exposure to a gradient of these wedge dosimetry. In our case a virtual wedge 600. The primary objective is to automate the process, reduce the time spent in obtaining the calibration curve (color-dose). Time negligible due to the limited availability of accelerators. This method of obtaining the calibration curve provides similar results to the commonly accepted either with irradiation uniform of a single film with different dose levels (multiband ladder) or with irradiation uniform of small rectangular piece of film , decreasing by a factor about 20, the time spent. (Author)

  3. Propylthiouracil and peripheral neuropathy

    Directory of Open Access Journals (Sweden)

    Valentina Van Boekel

    1992-06-01

    Full Text Available Peripheral neuropathy is a rare manifestation in hyperthyroidism. We describe the neurological manifestations of a 38 year old female with Graves' disease who developed peripheral neuropathy in the course of her treatment with propylthiouracil. After the drug was tapered off, the neurological signs disappeared. Therefore, we call attention for a possible toxic effect on peripheral nervous system caused by this drug.

  4. THE FLAT TAX - A COMPARATIVE STUDY OF THE EXISTING MODELS

    Directory of Open Access Journals (Sweden)

    Schiau (Macavei Laura - Liana

    2011-07-01

    Full Text Available In the two last decades the flat tax systems have spread all around the globe from East and Central Europe to Asia and Central America. Many specialists consider this phenomenon a real fiscal revolution, but others see it as a mistake as long as the new systems are just a feint of the true flat tax designed by the famous Stanford University professors Robert Hall and Alvin Rabushka. In this context this paper tries to determine which of the existing flat tax systems resemble the true flat tax model by comparing and contrasting their main characteristics with the features of the model proposed by Hall and Rabushka. The research also underlines the common features and the differences between the existing models. The idea of this kind of study is not really new, others have done it but the comparison was limited to one country. For example Emil Kalchev from New Bulgarian University has asses the Bulgarian income system, by comparing it with the flat tax and concluding that taxation in Bulgaria is not simple, neutral and non-distortive. Our research is based on several case studies and on compare and contrast qualitative and quantitative methods. The study starts form the fiscal design drawn by the two American professors in the book The Flat Tax. Four main characteristics of the flat tax system were chosen in order to build the comparison: fiscal design, simplicity, avoidance of double taxation and uniformity of the tax rates. The jurisdictions chosen for the case study are countries all around the globe with fiscal systems which are considered flat tax systems. The results obtained show that the fiscal design of Hong Kong is the only flat tax model which is built following an economic logic and not a legal sense, being in the same time a simple and transparent system. Others countries as Slovakia, Albania, Macedonia in Central and Eastern Europe fulfill the requirement regarding the uniformity of taxation. Other jurisdictions avoid the double

  5. Development of Partial Tubular Flat Knitting Fabric Composite Preform

    Directory of Open Access Journals (Sweden)

    Jiang Wei Qing

    2016-01-01

    Full Text Available After building some structures of partial tubular flat knitting fabric composite preform, the influencing factor on tubular section was analyzed and the fabric was knitted selectively. The partial tubular flat knitting fabric composite preform were Knitted by changing different yarn, row number and two-sided partial tubular flat knitting fabric. Multilayer sheet would be got after hot pressing and it has big market prospects and good application value.

  6. Assessing strain mapping by electron backscatter diffraction and confocal Raman microscopy using wedge-indented Si

    Energy Technology Data Exchange (ETDEWEB)

    Friedman, Lawrence H.; Vaudin, Mark D.; Stranick, Stephan J.; Stan, Gheorghe; Gerbig, Yvonne B.; Osborn, William; Cook, Robert F., E-mail: robert.cook@nist.gov

    2016-04-15

    The accuracy of electron backscatter diffraction (EBSD) and confocal Raman microscopy (CRM) for small-scale strain mapping are assessed using the multi-axial strain field surrounding a wedge indentation in Si as a test vehicle. The strain field is modeled using finite element analysis (FEA) that is adapted to the near-indentation surface profile measured by atomic force microscopy (AFM). The assessment consists of (1) direct experimental comparisons of strain and deformation and (2) comparisons in which the modeled strain field is used as an intermediate step. Direct experimental methods (1) consist of comparisons of surface elevation and gradient measured by AFM and EBSD and of Raman shifts measured and predicted by CRM and EBSD, respectively. Comparisons that utilize the combined FEA–AFM model (2) consist of predictions of distortion, strain, and rotation for comparison with EBSD measurements and predictions of Raman shift for comparison with CRM measurements. For both EBSD and CRM, convolution of measurements in depth-varying strain fields is considered. The interconnected comparisons suggest that EBSD was able to provide an accurate assessment of the wedge indentation deformation field to within the precision of the measurements, approximately 2×10{sup −4} in strain. CRM was similarly precise, but was limited in accuracy to several times this value. - Highlights: • We map strain by electron backscatter diffraction and confocal Raman microscopy. • The test vehicle is the multi-axial strain field of wedge-indented silicon. • Strain accuracy is assessed by direct experimental intercomparison. • Accuracy is also assessed by atomic force microscopy and finite element analyses. • Electron diffraction measurements are accurate; Raman measurements need refinement.

  7. Lung-conserving treatment of a pulmonary oligometastasis with a wedge resection and 131Cs brachytherapy.

    Science.gov (United States)

    Wernicke, A Gabriella; Parikh, Apurva; Yondorf, Menachem; Trichter, Samuel; Gupta, Divya; Port, Jeffrey; Parashar, Bhupesh

    2013-01-01

    Soft-tissue sarcomas most frequently metastasize to the lung. Surgical resection of pulmonary metastases is the primary treatment modality. Although lobectomy is widely acknowledged as the standard procedure to treat primary pulmonary tumors, the standard for pulmonary metastases is not well defined; furthermore, compromised lung function may tip the scales in favor of a less invasive approach. Here, we report the results of a patient treated with wedge resection and intraoperative cesium-131 ((131)Cs). A 58-year-old African American female was diagnosed with the American Joint Committee on Cancer Stage IIA mixed uterine leiomyosarcoma and underwent total abdominal hysterectomy and bilateral salpingo-oophorectomy followed by adjuvant external beam radiotherapy to a total dose of 45 Gy and vaginal brachytherapy to a total dose of 20 Gy. At 2 years, a routine CT scan of the chest revealed metastasis to right upper lobe of the lung. The patient's poor pulmonary function, related to a 45 pack-year smoking history and chronic emphysema, precluded a lobectomy. After the patient underwent a lung-sparing wedge resection of the pulmonary right upper lobe metastasis and intraoperative brachytherapy with (131)Cs seeds to a total dose of 80 Gy, she remained disease free in the implanted area. At a 2-year followup, imaging continued to reveal 100% local control of the area treated with wedge resection and intraoperative (131)Cs brachytherapy. The patient had no complications from this treatment. Such treatment approach may become an attractive option in patients with oligometastatic disease and compromised pulmonary function. Copyright © 2013 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  8. Assessing strain mapping by electron backscatter diffraction and confocal Raman microscopy using wedge-indented Si

    International Nuclear Information System (INIS)

    Friedman, Lawrence H.; Vaudin, Mark D.; Stranick, Stephan J.; Stan, Gheorghe; Gerbig, Yvonne B.; Osborn, William; Cook, Robert F.

    2016-01-01

    The accuracy of electron backscatter diffraction (EBSD) and confocal Raman microscopy (CRM) for small-scale strain mapping are assessed using the multi-axial strain field surrounding a wedge indentation in Si as a test vehicle. The strain field is modeled using finite element analysis (FEA) that is adapted to the near-indentation surface profile measured by atomic force microscopy (AFM). The assessment consists of (1) direct experimental comparisons of strain and deformation and (2) comparisons in which the modeled strain field is used as an intermediate step. Direct experimental methods (1) consist of comparisons of surface elevation and gradient measured by AFM and EBSD and of Raman shifts measured and predicted by CRM and EBSD, respectively. Comparisons that utilize the combined FEA–AFM model (2) consist of predictions of distortion, strain, and rotation for comparison with EBSD measurements and predictions of Raman shift for comparison with CRM measurements. For both EBSD and CRM, convolution of measurements in depth-varying strain fields is considered. The interconnected comparisons suggest that EBSD was able to provide an accurate assessment of the wedge indentation deformation field to within the precision of the measurements, approximately 2×10"−"4 in strain. CRM was similarly precise, but was limited in accuracy to several times this value. - Highlights: • We map strain by electron backscatter diffraction and confocal Raman microscopy. • The test vehicle is the multi-axial strain field of wedge-indented silicon. • Strain accuracy is assessed by direct experimental intercomparison. • Accuracy is also assessed by atomic force microscopy and finite element analyses. • Electron diffraction measurements are accurate; Raman measurements need refinement.

  9. Peripheral Neuropathy: Symptoms and Signs

    Science.gov (United States)

    ... Utah Research News Make a Difference Symptoms of Peripheral Neuropathy Print This Page Peripheral Neuropathy symptoms usually start ... more slowly over many years. The symptoms of peripheral neuropathy often include: A sensation of wearing an invisible “ ...

  10. Stationary solutions and asymptotic flatness I

    International Nuclear Information System (INIS)

    Reiris, Martin

    2014-01-01

    In general relativity, a stationary isolated system is defined as an asymptotically flat (AF) stationary spacetime with compact material sources. Other definitions that are less restrictive on the type of asymptotic could in principle be possible. Between this article and its sequel, we show that under basic assumptions, asymptotic flatness indeed follows as a consequence of Einstein's theory. In particular, it is proved that any vacuum stationary spacetime-end whose (quotient) manifold is diffeomorphic to R 3 minus a ball and whose Killing field has its norm bounded away from zero, is necessarily AF with Schwarzschildian fall off. The ‘excised’ ball would contain (if any) the actual material body, but this information is unnecessary to reach the conclusion. In this first article, we work with weakly asymptotically flat (WAF) stationary ends, a notion that generalizes as much as possible that of the AF end, and prove that WAF ends are AF with Schwarzschildian fall off. Physical and mathematical implications are also discussed. (paper)

  11. Significant strain accumulation between the deformation front and landward out-of-sequence thrusts in accretionary wedge of SW Taiwan revealed by cGPS and SAR interferometry

    Science.gov (United States)

    Tsai, M. C.

    2017-12-01

    High strain accumulation across the fold-and-thrust belt in Southwestern Taiwan are revealed by the Continuous GPS (cGPS) and SAR interferometry. This high strain is generally accommodated by the major active structures in fold-and-thrust belt of western Foothills in SW Taiwan connected to the accretionary wedge in the incipient are-continent collision zone. The active structures across the high strain accumulation include the deformation front around the Tainan Tableland, the Hochiali, Hsiaokangshan, Fangshan and Chishan faults. Among these active structures, the deformation pattern revealed from cGPS and SAR interferometry suggest that the Fangshan transfer fault may be a left-lateral fault zone with thrust component accommodating the westward differential motion of thrust sheets on both side of the fault. In addition, the Chishan fault connected to the splay fault bordering the lower-slope and upper-slope of the accretionary wedge which could be the major seismogenic fault and an out-of-sequence thrust fault in SW Taiwan. The big earthquakes resulted from the reactivation of out-of-sequence thrusts have been observed along the Nankai accretionary wedge, thus the assessment of the major seismogenic structures by strain accumulation between the frontal décollement and out-of-sequence thrusts is a crucial topic. According to the background seismicity, the low seismicity and mid-crust to mantle events are observed inland and the lower- and upper- slope domain offshore SW Taiwan, which rheologically implies the upper crust of the accretionary wedge is more or less aseimic. This result may suggest that the excess fluid pressure from the accretionary wedge not only has significantly weakened the prism materials as well as major fault zone, but also makes the accretionary wedge landward extension, which is why the low seismicity is observed in SW Taiwan area. Key words: Continuous GPS, SAR interferometry, strain rate, out-of-sequence thrust.

  12. Observations of ebb flows on tidal flats: Evidence of dewatering?

    Science.gov (United States)

    Rinehimer, J. P.; Thomson, J. M.; Chickadel, C.

    2010-12-01

    Incised channels are a common morphological feature of tidal flats. When the flats are inundated, flows are generally forced by the tidally varying sea surface height. During low tide, however, these channels continue to drain throughout flat exposure even without an upstream source of water. While the role of porewater is generally overlooked due to the low permeability of marine muds, it remains the only potential source of flows through the channels during low tide. In situ and remotely sensed observations (Figure 1) at an incised channel on a tidal flat in Willapa Bay from Spring 2010 indicate that dewatering of the flats may be driving these low tide flows. High resolution Aquadopp ADCP velocity profiles are combined with observations from tower-based infrared (IR) video to produce a complete time series of surface velocity measurements throughout low tide. The IR video observations provide a measurement of surface currents even when the channel depth is below the blanking distance of the ADCP (10 cm). As the depth within the channel drops from 50 cm to 10 cm surface velocities increase from 10 cm/s to 60 cm/s even as the tide level drops below the channel flanks and the flats are dry. As the drainage continues, the temperature of the flow rises throughout low tide, mirroring temperatures within the sediment bed on the tidal flat. Drainage salinity falls despite the lack of any freshwater input to the flat indicating that less saline porewater may be the source. The likely source of the drainage water is from the channel flanks where time-lapse video shows slumping and compaction of channel sediments. Velocity profiles, in situ temperatures, and IR observations also are consistent with the presence of fluid muds and a hyperpycnal, density driven outflow at the channel mouth highlighting a possible pathway for sediment delivery from the flats to the main distributary channels of the bay. Figure 1: Time series of tidal flat channel velocities and temperatures

  13. Numerical simulation and experimental verification of a flat two-phase thermosyphon

    International Nuclear Information System (INIS)

    Zhang Ming; Liu Zhongliang; Ma Guoyuan; Cheng Shuiyuan

    2009-01-01

    The flat two-phase thermosyphon is placed between the heat source and the heat sink, which can achieve the uniform heat flux distribution and improve the performance of heat sink. In this paper, a two-dimensional heat and mass transfer model for a disk-shaped flat two-phase thermosyphon is developed. By solving the equations of continuity, momentum and energy numerically, the vapor velocity and temperature distributions of the flat two-phase thermosyphon are obtained. An analysis is also carried out on the ability of flat two-phase thermosyphon to spread heat and remove hot spots. In order to observe boiling and condensation phenomena, a transparent flat two-phase thermosyphon is manufactured and studied experimentally. The experimental results are compared with numerical results, which verify the physical and mathematical model of the flat two-phase thermosyphon. In order to study the main factors affecting the axial thermal resistance of two-phase thermosyphon, the temperatures inside the flat two-phase thermosyphon are measured and analyzed

  14. Direct Numerical Simulation and Experimental Validation of Hypersonic Boundary-Layer Receptivity and Instability

    National Research Council Canada - National Science Library

    Zhong, Xiaolin

    2007-01-01

    .... During the three-year period, we have conducted extensive DNS studies on the receptivity of hypersonic boundary layer flows over a sharp wedge, a flat plate, a blunt cone, and the FRESH aeroshell...

  15. Application of a wedge strip anode in micro-pattern gaseous detectors

    International Nuclear Information System (INIS)

    Tian Yang; Yang Yigang; Li Yulan; Li Yuanjing

    2013-01-01

    The wedge strip anode (WSA) has been widely used in 2-D position-sensitive detectors. A circular WSA with an effective diameter of 52 mm is successfully coupled to a tripe gas electron multiplier (GEM) detector through a simple resistive layer. A spatial resolution of 440 μm (FWHM) is achieved for a 10 kVp X-ray using 1 atm Ar:CO 2 =70:30 gas. The simple electronics of only three channels makes it very useful in applications strongly requiring simple interface design, e.g. sealed tubes and high pressure detectors. (authors)

  16. Donating Peripheral Blood Stem Cells

    Science.gov (United States)

    ... Print this page My Cart Donating peripheral blood stem cells Peripheral blood stem cell (PBSC) donation is a nonsurgical procedure to collect ... Donating bone marrow Donor experiences videos Peripheral blood stem cell (PBSC) donation is one of two methods of ...

  17. Accessibility of low-income family flats in North Jakarta city

    Science.gov (United States)

    Feminin, T. A.; Wiranegara, H. W.; Supriatna, Y.

    2018-01-01

    The majority of relocated, low-income families in North Jakarta city who residing the flats, complained at decreasing their accessibility to the workplaces and to the social facilities. The aim of this research was to identify the changing of their accessibility before and after relocated, viewed from three dimensions: distance, travel time, and travel cost to the workplaces, educational facilities, and shopping areas. The research design was questionnaire survey containing the degree of accessibility before and after resided the flats. Five flats were chosen as cases. Their inhabitants were chosen as respondents which used simple random sampling. The result showed that their flats accessibility to the workplaces in all three dimensions was lower than when they resided in the slum area. Also, in distance and travel time accessibility to shopping areas was lower. Only accessibility to educational facilities measured in those three dimensions was higher after they moved. Supply for affordable public transport from their flats to reach their workplaces is needed to raise their accessibility. Also, they need subsidizeto rent of their flats so the burden to their income lesser.Using the ground space of their flats for retail activities was to make more accessible for their shopping activities.

  18. Converting nested algebra expressions into flat algebra expressions

    NARCIS (Netherlands)

    Paredaens, J.; Van Gucht, D.

    1992-01-01

    Nested relations generalize ordinary flat relations by allowing tuple values to be either atomic or set valued. The nested algebra is a generalization of the flat relational algebra to manipulate nested relations. In this paper we study the expressive power of the nested algebra relative to its

  19. Combining valgus knee brace and lateral foot wedges reduces external forces and moments in osteoarthritis patients

    NARCIS (Netherlands)

    Jafarnezhadgero, Amir Ali; Oliveira, Anderson S.; Mousavi, Seyed Hamed; Madadi-Shad, Morteza

    Osteoarthritis progression can be related to the external knee adduction and flexion moments during walking. Lateral foot wedges and knee braces have been used as treatment for osteoarthritis, but little is known about their influence on knee joint moments generated in the sagittal and frontal

  20. Public involvement in cleanup - the Rocky Flats experience

    International Nuclear Information System (INIS)

    Paukert, J.; Pennock, S.; Schassburger, R.

    1992-01-01

    The U.S. Department of Energy's Rocky Flats Plant recently completed and implemented the Rocky Flats Plant Community Relations Plan for public involvement in environmental restoration of the site. The plan was developed in cooperation with the plant's regulators, the U.S. Environmental Protection Agency and the Colorado Department of Health. In addition, citizens near the plant played a significant role in shaping the document through extensive community interviews and public comment. The result of these cooperative efforts is a plan that meets and exceeds the applicable federal and state community relations requirements for a cleanup program. In fact, the U.S. Environmental Protection Agency has used the Rocky Flats Plant Community Relations Plants a model for similar plans at other federal facilities. Plan development, however, is only the starting point for an effective community relations effort. The Rocky Flats Plant and the public will face many challenges together as we implement the plan and build a partnership for addressing environmental cleanup issues. (author)

  1. Flat beams in the SLC

    International Nuclear Information System (INIS)

    Adolphsen, C.; Barklow, T.; Burke, D.; Decker, F.J.; Emma, P.; Hildreth, M.; Himel, T.; Krejcik, P.; Limberg, T.; Minty, M.

    1993-01-01

    The Stanford Linear Collider was designed to operate with round beams; horizontal and vertical emittance made equal in the damping rings. The main motivation was to facilitate the optical matching through beam lines with strong coupling elements like the solenoid spin rotator magnets and the SLC arcs. Tests in 1992 showed that open-quote flat close-quote beams with a vertical to horizontal emittance ratio of around 1/10 can be successfully delivered to the end of the linac. Techniques developed to measure and control the coupling of the SLC arcs allow These beams to be transported to the Interaction Point (IP). Before flat beams could be used for collisions with polarized electrons, a new method of rotating the electron spin orientation with vertical arc orbit bumps had to be developed. Early in the 1993 run, the SLC was switched to open-quote flat close-quote beam operation. Within a short time the peak luminosity of the previous running cycle was reached and then surpassed. The average daily luminosity is now a factor of about two higher than the best achieved last year. In the following the authors present an overview of the problems encountered and their solutions for different parts of the SLC

  2. Flat oysters in the Eierlandse Gat, Wadden Sea

    NARCIS (Netherlands)

    Have, van der T.M.; Kamermans, P.; Zee, van der E.M.

    2018-01-01

    This report presents the results of a short survey of flat oysters (Ostrea edulis) in the Western Wadden Sea. Ten sites were visited and flat oysters were found on nine locations in the Eijerlandse gat. Empty cockleshells and live and dead Pacific oysters provided the main settlement substrate. The

  3. Programming the shape-shifting of flat soft matter

    NARCIS (Netherlands)

    van Manen, T.; Janbaz, S.; Zadpoor, A.A.

    2018-01-01

    Shape-shifting of flat materials into the desired 3D configuration is an alternative design route for fabrication of complex 3D shapes, which provides many benefits such as access to the flat material surface and the ability to produce well-described motions. The advanced production techniques

  4. Evaluation Of Open, Wedge Filtered And Half Block Profile For Single And Plan Parallel Field For 60Co Teletherapy Unit

    International Nuclear Information System (INIS)

    Heru-Prasetio; Nasukha; Soejoko, Djarwani S

    2003-01-01

    TPS shall be evaluated with experimental data before it is used for patient treatment. This experiment was performed using small water phantom, at the depth of 10 cm, SSD technique for single beam and 16 cm, SAD technique for plan parallel beam. Measuring device used in this experiment is Farmer 2571 detector. It was found differences between experiment and TPS iSis are not significant. Single field experiment and TPS differences of 0.6%, 3.6% and 0.1% for open, wedge filter and half-blocked field, for plan parallel experiment and TPS differences are 2.1%, 2% and 2.4% for open, wedge filter and half-blocked field. (author)

  5. A numerical study on the behavior of the water meniscus formed between a flat surface and a flat or circular tip

    Energy Technology Data Exchange (ETDEWEB)

    Son, Sung Wan; Ha, Man Yeong; Yoon, Hyun Sik; Kim, Chang Min [Pusan National University, Busan (Korea, Republic of); Kim, Sang Sun [Korea Aerospace Industries, Sacheon (Korea, Republic of)

    2014-04-15

    We numerically investigated the behavior of the water meniscus formed between a flat surface and a tip surface, which is flat or circular in shape, using the lattice Boltzmann method (LBM). The shape of the water meniscus formed between the flat bottom surface and the tip surface depends on the tip shape and the interaction between the water meniscus and the bottom or tip surface. The interaction is determined by the contact angles of the bottom and tip surfaces, resulting in different contact lengths between the water meniscus and the bottom or tip surface. The difference in these contact lengths depends on the effects of both the tip curvature and the interaction between the water meniscus and the bottom or tip surface. We classified the shapes of the water meniscus into seven different patterns as a function of the contact angles of the flat bottom and tip surfaces: concave, semi-concave, inverse semi-concave, column, convex, semiconvex, and inverse semi-convex.

  6. A numerical study on the behavior of the water meniscus formed between a flat surface and a flat or circular tip

    International Nuclear Information System (INIS)

    Son, Sung Wan; Ha, Man Yeong; Yoon, Hyun Sik; Kim, Chang Min; Kim, Sang Sun

    2014-01-01

    We numerically investigated the behavior of the water meniscus formed between a flat surface and a tip surface, which is flat or circular in shape, using the lattice Boltzmann method (LBM). The shape of the water meniscus formed between the flat bottom surface and the tip surface depends on the tip shape and the interaction between the water meniscus and the bottom or tip surface. The interaction is determined by the contact angles of the bottom and tip surfaces, resulting in different contact lengths between the water meniscus and the bottom or tip surface. The difference in these contact lengths depends on the effects of both the tip curvature and the interaction between the water meniscus and the bottom or tip surface. We classified the shapes of the water meniscus into seven different patterns as a function of the contact angles of the flat bottom and tip surfaces: concave, semi-concave, inverse semi-concave, column, convex, semiconvex, and inverse semi-convex

  7. Tumors of peripheral nerves

    International Nuclear Information System (INIS)

    Ho, Michael; Lutz, Amelie M.

    2017-01-01

    Differentiation between malignant and benign tumors of peripheral nerves in the early stages is challenging; however, due to the unfavorable prognosis of malignant tumors early identification is required. To show the possibilities for detection, differential diagnosis and clinical management of peripheral nerve tumors by imaging appearance in magnetic resonance (MR) neurography. Review of current literature available in PubMed and MEDLINE, supplemented by the authors' own observations in clinical practice. Although not pathognomonic, several imaging features have been reported for a differentiation between distinct peripheral nerve tumors. The use of MR neurography enables detection and initial differential diagnosis in tumors of peripheral nerves. Furthermore, it plays an important role in clinical follow-up, targeted biopsy and surgical planning. (orig.) [de

  8. Criteria impacting shipments of Rocky Flats Plant radioactive mixed wastes

    International Nuclear Information System (INIS)

    Clawson, R.L.; Eide, J.H.

    1992-05-01

    Westinghouse Hanford Company, Transportation and Packaging Division, under contract for the Los Alamos Technology Office-Rocky Flats Plant, has developed this synopsis report to be used as a reference in the development of the Rocky Flats Plant Comprehensive Treatment and Management Plan and the Rocky Flats Plant Residue Elimination Plan. This report represents the criteria for packaging, shipping, and transporting Rocky Flats Plant radioactive mixed wastes. It is a compilation of state and federal regulations, US Department of Energy orders, and acceptance criteria specific to US Department of Energy radioactive mixed waste treatment, storage and disposal facilities

  9. Evaluation of Antigen-Specific IgM and IgG Production during an In Vitro Peripheral Blood Mononuclear Cell Culture Assay

    Directory of Open Access Journals (Sweden)

    Yoshiko Matsuda

    2017-07-01

    Full Text Available The recent attention given to diseases associated with memory B-cell (mBC-produced antibodies (Abs suggests the need for a similar in vitro assay to evaluate the functions of mBCs. Here, we cultured peripheral blood mononuclear cells (PBMCs with the intent to collect mBC-derived Abs in vitro and maintain their cell–cell contact-dependent interactions with helper T-cells. PBMCs were cultured with interleukin (IL-21, CpG-oligodeoxynucleotides (ODN, phorbol myristate acetate (PMA, and phytohemagglutinin/leucoagglutinin (PHA-L in 24-well flat-bottom plates (5 × 105 cells/well. A culture supernatant analysis of PBMCs from healthy donors (n = 10 indicated that antigen-specific IgM Ab levels in a PBMC culture supernatant might be better able to demonstrate the antigen sensitization status in a smaller peripheral blood sample, compared to IgG because Epstein–Barr virus-specific IgM mBCs circulate peripherally at a significantly higher frequency once antiviral humoral immunity has stabilized. Thus, our in vitro assay demonstrated the potential significance of antigen-specific IgM Ab production in the culture supernatants. Furthermore, an analysis of cultured PBMCs from allograft kidney recipients (n = 16 sensitized with de novo donor-specific human leukocyte antigen (HLA-specific Abs (DSAs showed that IgM-type HLA-specific Abs were detected mainly from the culture supernatants from PBMCs of patients with stable graft function, whereas IgG isotype HLA Abs were detectable only from patients with biopsy-proven antibody-mediated rejection. In other words, these IgG isotype Abs also represented an activated humoral immune response in vivo. Additionally, IgM- and IgG-expressing mBCs from healthy donors (n = 5 were cultured with IL-21, CpG-ODN, and a supernatant produced by stimulating CD19+ B-cell-depleted PBMCs with PHA-L and PMA in 24-well flat-bottom plates (1 × 105 cells/well, and the resulting in vitro analysis provided some

  10. Mantle wedge infiltrated with saline fluids from dehydration and decarbonation of subducting slab.

    Science.gov (United States)

    Kawamoto, Tatsuhiko; Yoshikawa, Masako; Kumagai, Yoshitaka; Mirabueno, Ma Hannah T; Okuno, Mitsuru; Kobayashi, Tetsuo

    2013-06-11

    Slab-derived fluids play an important role in heat and material transfer in subduction zones. Dehydration and decarbonation reactions of minerals in the subducting slab have been investigated using phase equilibria and modeling of fluid flow. Nevertheless, direct observations of the fluid chemistry and pressure-temperature conditions of fluids are few. This report describes CO2-bearing saline fluid inclusions in spinel-harzburgite xenoliths collected from the 1991 Pinatubo pumice deposits. The fluid inclusions are filled with saline solutions with 5.1 ± 1.0% (wt) NaCl-equivalent magnesite crystals, CO2-bearing vapor bubbles, and a talc and/or chrysotile layer on the walls. The xenoliths contain tremolite amphibole, which is stable in temperatures lower than 830 °C at the uppermost mantle. The Pinatubo volcano is located at the volcanic front of the Luzon arc associated with subduction of warm oceanic plate. The present observation suggests hydration of forearc mantle and the uppermost mantle by slab-derived CO2-bearing saline fluids. Dehydration and decarbonation take place, and seawater-like saline fluids migrate from the subducting slab to the mantle wedge. The presence of saline fluids is important because they can dissolve more metals than pure H2O and affect the chemical evolution of the mantle wedge.

  11. Preliminary assessment of potential underground stability (wedge and spalling) at Forsmark, Simpevarp and Laxemar sites

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Derek [Univ. of Alberta, Edmonton (Canada). Geotechnical Engineering

    2005-12-15

    In SKB's Underground Design Premises the objective in the early design phase is to estimate if there is sufficient space for the repository at a site. One of the conditions that could limit the space available is stability of the underground openings, i.e., deposition tunnels and deposition boreholes. The purpose of this report is to provide a preliminary assessment of the potential for wedge instability and spalling that may be encountered at the Forsmark, Simpevarp and Laxemar sites based on information from the site investigations program up to July 30, 2004. The rock mass spalling strength was defined using the in-situ results from SKB's Aespoe Pillar Stability Experiment and AECL's Mine-by Experiment. These experiments suggest that the rock mass spalling strength for crystalline rocks can be estimated as 0.57 of the mean laboratory uniaxial compressive strength. A probability-based methodology utilizing this in-situ rock mass spalling strength has been developed for assessing the risk for spalling in a repository at the Forsmark, Simpevarp and Laxemar sites. The in-situ stresses and the uniaxial compressive strength data from these sites were used as the bases for the analyses. Preliminary findings from all sites suggest that, generally, the risk for spalling increases as the depth of the repository increases, simply because the stress magnitudes increase with depth. The depth at which the risk for spalling is significant, depends on the individual sites which are discussed below. The greatest uncertainty in the spalling analyses for Forsmark is related to the uncertainty in the horizontal stress magnitudes and associated stress gradients with depth. The confidence in these analyses can only be increased by increasing the confidence in the stress and geology model for the site. From the analyses completed it appears that spalling in the deposition tunnels can be controlled by orienting the tunnels approximately parallel to the maximum horizontal

  12. Generation of shape-invariant flat-top laser beams

    CSIR Research Space (South Africa)

    Ait-Ameur, K

    2015-02-01

    Full Text Available A great number of laser applications need in place of the usual Gaussian beam a flat-top intensity profile in the focal plane of a focusing lens. In general the transformation of the laser beam from the Gaussian to the flat-top shape is made by a...

  13. Peripheral dentinogenic ghost cell tumor

    Directory of Open Access Journals (Sweden)

    Sushant S Kamat

    2013-01-01

    Full Text Available Dentinogenic ghost cell tumors (DGCT are uncommon lesions mainly with rare peripheral types. This report presents a case of peripheral DGCT on the left side of the mandibular alveolar ridge of a heavy smoker, a 68-year-old man, with main presenting feature as a mild pain. Submandibular lymphadenopathy and radiological "saucerization" were evident. Differential diagnosis included fibroma, neurofibroma, peripheral ameloblastoma, peripheral odontogenic fibroma, and peripheral giant cell granuloma. Histologically, ameloblastoma-like epithelial elements were seen in association with grouped ghost cells. Proliferating polyhedral cells and stellate reticulum-like cells with various densities were spread over a wide range of the field. The lesion was curetted and after 2 years of follow up, it did not recur.

  14. Structural control of the Gagua "Wedge" Zone east of Taiwan Island on the southern Okinawa Trough

    Institute of Scientific and Technical Information of China (English)

    ZHENG; Yanpeng; LIU; Baohua; WU; Jinlong; LIANG; Ruicai; L

    2005-01-01

    Based on compositive analysis and interpretation of the observed and historical data, the geophysical field characters and structural properties of the Gagua "Wedge" Zone of the sea area east of Taiwan Island and the primary tectonic stress direction and its variabilities of backarc spreading in the southern Okinawa Trough are studied. It is concluded from the study results that the Gagua "Wedge" Zone is structurally consistent with the Gagua ridge and two fault basins on both sides of the Gagua ridge, and adjusts the moving direction and distance of the western Philippine Sea plate to make the northwestward motion of the plate on its east side change to the northward subduction of the plate on its west side so that the primary tectonic stress direction of the Okinawa Trough changed from NW-SE to nearly N-S, which provided the stress source for the Okinawa Trough to enter the second spreading stage.

  15. The rocky flats controversy on radionuclide soil action levels

    International Nuclear Information System (INIS)

    Earle, T.C.

    2004-01-01

    This report describes how stakeholder involvement processes led to the successful resolution of a dispute over radionuclide soil action levels at the Rocky Flats Site near Denver, Colorado. During the Cold War Era, Rocky Flats, a plutonium fabrication plant, was part of the American government's multi-site nuclear weapons production facilities. Although the Rocky Flats plant had significant positive effects on the local economy, it became a target of public protest due to concerns over both public safety in the area surrounding the site and global nuclear proliferation. In the late 1980's, local safety concerns led to investigations by state and federal agencies. In 1992, with the Cold War ended, the Department of Energy decided to decommission the Rocky Flats site and to begin the long process of decontamination. (author)

  16. Unitarity in three-dimensional flat space higher spin theories

    International Nuclear Information System (INIS)

    Grumiller, D.; Riegler, M.; Rosseel, J.

    2014-01-01

    We investigate generic flat-space higher spin theories in three dimensions and find a no-go result, given certain assumptions that we spell out. Namely, it is only possible to have at most two out of the following three properties: unitarity, flat space, non-trivial higher spin states. Interestingly, unitarity provides an (algebra-dependent) upper bound on the central charge, like c=42 for the Galilean W_4"("2"−"1"−"1") algebra. We extend this no-go result to rule out unitary “multi-graviton” theories in flat space. We also provide an example circumventing the no-go result: Vasiliev-type flat space higher spin theory based on hs(1) can be unitary and simultaneously allow for non-trivial higher-spin states in the dual field theory.

  17. Wedge-Splitting Test – Determination of Minimal Starting Notch Length for Various Cement Based Composites

    Czech Academy of Sciences Publication Activity Database

    Seitl, Stanislav; Klusák, Jan; Veselý, V.; Řoutil, L.

    452-453, - (2011), s. 81-84 ISSN 1013-9826 R&D Projects: GA AV ČR KJB200410901; GA ČR GA103/08/0963 Institutional research plan: CEZ:AV0Z20410507 Keywords : wedge-splitting test, cementitious composites, quasi-brittle fracture, brittle fracture Subject RIV: JL - Materials Fatigue, Friction Mechanics www.scientific.net

  18. Physical modeling and monitoring of the process of thermal-erosion of an ice-wedge during a partially-controlled field experiment (Bylot Island, NU, Canada)

    Science.gov (United States)

    Godin, E.; Fortier, D.

    2013-12-01

    Syngenetic ice-wedges polygons are widespread periglacial features of the Arctic. On Bylot Island, Nunavut, Canada, numerous thermo-erosion gullies up to several 100's m in length developed in polygonal wetlands during the last decades. These gullies contributed to drainage of these wetlands and changed dramatically local ecological conditions. Concentrated and repeated snowmelt surface runoff infiltrated frost cracks, where convective heat transfer between flowing water and ice initiated piping in ice wedges leading to the rapid development of tunnels and gullies in the permafrost (Fortier D. et al., 2007). We conducted field experiments to quantify the convection process and speed of ice wedges ablation. The experiments were accomplished between the 23/06/2013 and the 05/07/2013 over A; an exposed sub-horizontal ice-wedge surface and B; a tunnel in an ice-wedge crack. The ice was instrumented with graduated sticks to calculate the ice ablation following the flow of a defined amount of water. A fixed quantity of water obtained from a nearby waterfall was diverted over the ice through a PVC pipe. Water temperature Wt (K), quantity Wq (L s-1 or m3 s-1), ice ablation rate Iar (m s-1) and convective heat transfer coefficient α (W m-2 K) were obtained during the 5 experiments. The objective of this paper is to quantify the heat transfer process from field measurements from an ice wedge under ablation and to compare with coefficients from previous researches and in the literature. For each experiment with the ice-surface scenario, water temperature varied between 280 K and 284 K. Discharge varied between 0.0001 and 0.0003 m3 s-1. Ablation rate varied between 1.8 * 10-5 and 0.0004 m s-1. Heat transfer coefficient varied between 706 and 11 655 W m-2 K and between 54 and 4802 W of heat was transferred to ice. For each experiment with the tunnel scenario, water temperature was 284 K × 1 K. Discharge was 0.0002 m3 s-1. Ablation rate varied between 0.0001 and 0.0003 m s-1

  19. Enhanced performance of fast-response 3-hole wedge probes for transonic flows in axial turbomachinery

    Energy Technology Data Exchange (ETDEWEB)

    Delhaye, D.; Paniagua, G. [von Karman Institute for Fluid Dynamics, Turbomachinery and Propulsion Department, Rhode-Saint-Genese (Belgium); Fernandez Oro, J.M. [Universidad de Oviedo, Area de Mecanica de Fluidos, Gijon (Spain); Denos, R. [European Commission, Directorate General for Research, Brussels (Belgium)

    2011-01-15

    The paper presents the development and application of a three-sensor wedge probe to measure unsteady aerodynamics in a transonic turbine. CFD has been used to perform a detailed uncertainty analysis related to probe-induced perturbations, in particular the separation zones appearing on the wedge apex. The effects of the Reynolds and Mach numbers are studied using both experimental data together with CFD simulations. The angular range of the probe and linearity of the calibration maps are enhanced with a novel zonal calibration technique, used for the first time in compressible flows. The data reduction methodology is explained and demonstrated with measurements performed in a single-stage high-pressure turbine mounted in the compression tube facility of the von Karman Institute. The turbine was operated at subsonic and transonic pressure ratios (2.4 and 5.1) for a Reynolds number of 10{sup 6}, representative of modern engine conditions. Complete maps of the unsteady flow angle and rotor outlet Mach number are documented. These data allow the study of secondary flows and rotor trailing edge shocks. (orig.)

  20. Transport and optical properties of c-axis oriented wedge shaped GaN nanowall network grown by molecular beam epitaxy

    Energy Technology Data Exchange (ETDEWEB)

    Bhasker, H. P.; Dhar, S. [Department of Physics, Indian Institute of Technology Bombay, Powai, Mumbai, Maharashtra-400076 (India); Thakur, Varun; Kesaria, Manoj; Shivaprasad, S. M. [Jawaharlal Nehru Centre for Advanced Scientific Research (JNCASR) Bangalore- 560064 (India)

    2014-02-21

    The transport and optical properties of wedge-shaped nanowall network of GaN grown spontaneously on cplane sapphire substrate by Plasma-Assisted Molecular Beam Epitaxy (PAMBE) show interesting behavior. The electron mobility at room temperature in these samples is found to be orders of magnitude higher than that of a continuous film. Our study reveals a strong correlation between the mobility and the band gap in these nanowall network samples. However, it is seen that when the thickness of the tips of the walls increases to an extent such that more than 70% of the film area is covered, it behaves close to a flat sample. In the sample with lower surface coverage (≈40% and ≈60%), it was observed that the conductivity, mobility as well as the band gap increase with the decrease in the average tip width of the walls. Photoluminescence (PL) experiments show a strong and broad band edge emission with a large (as high as ≈ 90 meV) blue shift, compared to that of a continuous film, suggesting a confinement of carriers on the top edges of the nanowalls. The PL peak width remains wide at all temperatures suggesting the existence of a high density of tail states at the band edge, which is further supported by the photoconductivity result. The high conductivity and mobility observed in these samples is believed to be due to a “dissipation less” transport of carriers, which are localized at the top edges (edge states) of the nanowalls.

  1. Transport and optical properties of c-axis oriented wedge shaped GaN nanowall network grown by molecular beam epitaxy

    International Nuclear Information System (INIS)

    Bhasker, H. P.; Dhar, S.; Thakur, Varun; Kesaria, Manoj; Shivaprasad, S. M.

    2014-01-01

    The transport and optical properties of wedge-shaped nanowall network of GaN grown spontaneously on cplane sapphire substrate by Plasma-Assisted Molecular Beam Epitaxy (PAMBE) show interesting behavior. The electron mobility at room temperature in these samples is found to be orders of magnitude higher than that of a continuous film. Our study reveals a strong correlation between the mobility and the band gap in these nanowall network samples. However, it is seen that when the thickness of the tips of the walls increases to an extent such that more than 70% of the film area is covered, it behaves close to a flat sample. In the sample with lower surface coverage (≈40% and ≈60%), it was observed that the conductivity, mobility as well as the band gap increase with the decrease in the average tip width of the walls. Photoluminescence (PL) experiments show a strong and broad band edge emission with a large (as high as ≈ 90 meV) blue shift, compared to that of a continuous film, suggesting a confinement of carriers on the top edges of the nanowalls. The PL peak width remains wide at all temperatures suggesting the existence of a high density of tail states at the band edge, which is further supported by the photoconductivity result. The high conductivity and mobility observed in these samples is believed to be due to a “dissipation less” transport of carriers, which are localized at the top edges (edge states) of the nanowalls

  2. Dynamics of intertidal flats in the Loire estuary

    Science.gov (United States)

    Kervella, Stephane; Sottolichio, Aldo; Bertier, Christine

    2014-05-01

    Tidal flats form at the edges of many tidal estuaries, and are found in broad climatic regions. Their evolution plays a fundamental role in maintaining the morphodynamic equilibrium of an estuary. The Loire estuary is one of the largest macrotidal systems of the french atlantic coast. Since 200 years, its geometry has been drastically modified through channeling, deepening, embanking, infilling of secondary channels, etc. These works altered many intertidal areas. In the recent years, efforts for the rectification of the morphology have been made in order to restore the ecology of the estuary. In this context, it is crucial to better understand the dynamics of intertidal flats, still poorly understood in this estuary. The aim of this work is to analyse a series of original observations conducted for the first time in two intertidal flats of the central Lore estuary between 2008 and 2010. The tidal flats are situated in the northern bank, at 12 and 17 km upstream from the mouth respectively. Six Altus altimeters were deployed at two cross shore transects, measuring continuously and at a high-frequency bed altimetry and water level, providing information on tide and waves. At the semi-diurnal tidal scale, the surficial sediment of intertidal flats is permanently mobilized. Altimetry variations are low, and their amplitude varies as a function of tides and river flow. At the scale of several months, the sedimentation is controlled by the position of the turbidity maximum (and therefore by the river flow) and also by the tidal amplitude. During low river flow periods, altimetry variations are only due to tidal cycles. During decaying tides, suspended sediment settle mainly on the lower part of the tidal flats, forming fluid mud layers of several cm thick, which can consolidate rapidly; under rising tides, the increasing of tidal currents promotes erosion. During periods of high river flow, the turbidity maximum shifts to the lower estuary. The higher suspended sediment

  3. Opening wedge trapezial osteotomy as possible treatment for early trapeziometacarpal osteoarthritis: a biomechanical investigation of radial subluxation, contact area, and contact pressure.

    Science.gov (United States)

    Cheema, Tahseen; Salas, Christina; Morrell, Nathan; Lansing, Letitia; Reda Taha, Mahmoud M; Mercer, Deana

    2012-04-01

    Radial subluxation and cartilage thinning have been associated with initiation and accelerated development of osteoarthritis of the trapeziometacarpal joint. Few investigators have reported on the benefits of opening wedge trapezial osteotomy for altering the contact mechanics of the trapeziometacarpal joint as a possible deterrent to the initiation or progression of osteoarthritis. We used cadaveric specimens to determine whether opening wedge osteotomy of the trapezium was successful in reducing radial subluxation of the metacarpal base and to quantify the contact area and pressure on the trapezial surface during simulated lateral pinch. We used 8 fresh-frozen specimens in this study. The flexor pollicis longus, abductor pollicis longus, adductor pollicis, abductor pollicis brevis, and flexor pollicis brevis/opponens pollicis tendons were each loaded to simulate the thumb in lateral pinch position. We measured radial subluxation from anteroposterior radiographs before and after placement of a 15° wedge. We used real-time sensors to analyze contact pressure and contact area distribution on the trapezium. Center of force in the normal joint under lateral pinch loading was primarily located in the dorsal region of the trapezium. After wedge placement, contact pressure increased in the ulnar-dorsal region by 76%. Mean contact area increased in the ulnar-dorsal region from 0.05 to 0.07 cm(2), and in the ulnar-volar region from 0.003 to 0.024 cm(2). The average reduction in joint subluxation was 64%. The 15° opening wedge osteotomy of the trapezium reduced radial subluxation of the metacarpal on the trapezium and increased contact pressure and contact area away from the diseased compartments of the trapezial surface. Trapezial osteotomy addresses the 2 preeminent theories about the initiation and progression of osteoarthritis. By reducing radial subluxation and altering contact pressure and contact area, trapezial osteotomy may prove an alternative to first

  4. Natural orifice transgastric endoscopic wedge hepatic resection in an experimental model using an intuitively controlled master and slave transluminal endoscopic robot (MASTER).

    Science.gov (United States)

    Phee, S J; Ho, K Y; Lomanto, D; Low, S C; Huynh, V A; Kencana, A P; Yang, K; Sun, Z L; Chung, S C Sydney

    2010-09-01

    The lack of triangulation of standard endoscopic devices limits the degree of freedom for surgical maneuvers during natural orifice transluminal endoscopic surgery (NOTES). This study explored the feasibility of adapting an intuitively controlled master and slave transluminal endoscopic robot (MASTER) the authors developed to facilitate wedge hepatic resection in NOTES. The MASTER consists of a master controller, a telesurgical workstation, and a slave manipulator that holds two end-effectors: a grasper, and a monopolar electrocautery hook. The master controller is attached to the wrist and fingers of the operator and connected to the manipulator by electrical and wire cables. Movements of the operator are detected and converted into control signals driving the slave manipulator via a tendon-sheath power transmission mechanism allowing nine degrees of freedom. Using this system, wedge hepatic resection was performed through the transgastric route on two female pigs under general anesthesia. Entry into the peritoneal cavity was via a 10-mm incision made on the anterior wall of the stomach by the electrocautery hook. Wedge hepatic resection was performed using the robotic grasper and hook. Hemostasis was achieved with the electrocautery hook. After the procedure, the resected liver tissue was retrieved through the mouth using the grasper. Using the MASTER, transgastric wedge hepatic resection was successfully performed on two pigs with no laparoscopic assistance. The entire procedure took 9.4 min (range, 8.5-10.2 min), with 7.1 min (range, 6-8.2 min) spent on excision of the liver tissue. The robotics-controlled device was able to grasp, retract, and excise the liver specimen successfully in the desired plane. This study demonstrated for the first time that the MASTER could effectively mitigate the technical constraints normally encountered in NOTES procedures. With it, the triangulation of surgical tools and the manipulation of tissue became easy, and wedge hepatic

  5. Integrated Weed Control for Land Stewardship at Legacy Management's Rocky Flats Site in Colorado - 13086

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Jody K. [Stoller LMS Team, Contractor to the U.S. Department of Energy Office of Legacy Management, 11025 Dover Street, Suite 1000, Westminster, Colorado 80021 (United States)

    2013-07-01

    Land stewardship is one of nine sustainability programs in the U.S. Department of Energy's Environmental Management System. Land stewardship includes maintaining and improving ecosystem health. At the Rocky Flats Site near Westminster, Colorado, land stewardship is an integral component of the Office of Legacy Management's post-closure monitoring and management at the site. Nearly 263 hectares (650 acres) were disturbed and re-vegetated during site cleanup and closure operations. Proactive management of revegetation areas is critical to the successful reestablishment of native grasslands, wetlands, and riparian communities. The undisturbed native plant communities that occur at the site also require active management to maintain the high-quality wetlands and other habitats that are home to numerous species of birds and other wildlife such as elk and deer, rare plant communities, and the federally listed threatened Preble's meadow jumping mouse. Over the past several decades, an increase of Noxious weeds has impacted much of Colorado's Front Range. As a result, weed control is a key component of the land stewardship program at Rocky Flats. Thirty-three species of state-listed Noxious weeds are known to occur in the Central and Peripheral Operable Units at Rocky Flats, along with another five species that are considered invasive at the site. Early detection and rapid response to control new invasive species is crucial to the program. An integrated weed control/vegetation management approach is key to maintaining healthy, sustainable plant communities that are able to resist Noxious weed invasions. Weed mapping, field surveys, and field-staff training sessions (to learn how to identify new potential problem species) are conducted to help detect and prevent new weed problems. The integrated approach at Rocky Flats includes administrative and cultural techniques (prevention), mechanical controls, biological controls, and chemical controls. Several

  6. 2D Traveling Wave Array Employing a Trapezoidal Dielectric Wedge for Beam Steering

    Science.gov (United States)

    Host, Nicholas K.; Chen, Chi-Chih; Volakis, John L.; Miranada, Felix A.

    2014-01-01

    This presentation addresses the progress made so far in the development of an antenna array with reconfigurable transmission line feeds connecting each element in series. In particular, 2D traveling wave array employing trapezoidal Dielectric Wedge for Beam Steering will be discussed. The presentation includes current status of the effort and suggested future work. The work is being done as part of the NASA Office of the Chief Technologist's Space Technology Research Fellowship (NSTRF).

  7. Beauty and cuteness in peripheral vision

    Science.gov (United States)

    Kuraguchi, Kana; Ashida, Hiroshi

    2015-01-01

    Guo et al. (2011) showed that attractiveness was detectable in peripheral vision. Since there are different types of attractiveness (Rhodes, 2006), we investigated how beauty and cuteness are detected in peripheral vision with a brief presentation. Participants (n = 45) observed two Japanese female faces for 100 ms, then were asked to respond which face was more beautiful (or cuter). The results indicated that both beauty and cuteness were detectable in peripheral vision, but not in the same manner. Discrimination rates for judging beauty were invariant in peripheral and central vision, while discrimination rates for judging cuteness declined in peripheral vision as compared with central vision. This was not explained by lower resolution in peripheral vision. In addition, for male participants, it was more difficult to judge cuteness than beauty in peripheral vision, thus suggesting that gender differences can have a certain effect when judging cuteness. Therefore, central vision might be suitable for judging cuteness while judging beauty might not be affected by either central or peripheral vision. This might be related with the functional difference between beauty and cuteness. PMID:25999883

  8. Mechanical aspects of degree of cement bonding and implant wedge effect.

    Science.gov (United States)

    Yoon, Yong-San; Oxland, Thomas R; Hodgson, Antony J; Duncan, Clive P; Masri, Bassam A; Choi, Donok

    2008-11-01

    The degree of bonding between the femoral stem and cement in total hip replacement remains controversial. Our objective was to determine the wedge effect by debonding and stem taper angle on the structural behavior of axisymmetric stem-cement-bone cylinder models. Stainless steel tapered plugs with a rough (i.e. bonded) or smooth (i.e. debonded) surface finish were used to emulate the femoral stem. Three different stem taper angles (5 degrees , 7.5 degrees , 10 degrees ) were used for the debonded constructs. Non-tapered and tapered (7.5 degrees ) aluminum cylindrical shells were used to emulate the diaphyseal and metaphyseal segments of the femur. The cement-aluminum cylinder interface was designed to have a shear strength that simulated bone-cement interfaces ( approximately 8MPa). The test involved applying axial compression at a rate of 0.02mm/s until failure. Six specimens were tested for each combination of the variables. Finite element analysis was used to enhance the understanding of the wedge effect. The debonded stems sustained about twice as much load as the bonded stem, regardless of taper angle. The metaphyseal model carried 35-50% greater loads than the diaphyseal models and the stem taper produced significant differences. Based on the finite element analysis, failure was most probably by shear at the cement-bone interface. Our results in this simplified model suggest that smooth (i.e. debonded) stems have greater failure loads and will incur less slippage or shear failure at the cement-bone interface than rough (i.e. bonded) stems.

  9. Wedge splitting test method: quantification of influence of glued marble plates by two-parameter fracture mechanics

    Czech Academy of Sciences Publication Activity Database

    Seitl, Stanislav; Nieto Garcia, B.; Merta, I.

    2014-01-01

    Roč. 30, OCT (2014), s. 174-181 ISSN 1971-8993 R&D Projects: GA MŠk(CZ) 7AMB14AT012 Institutional support: RVO:68081723 Keywords : Wedge splitting test * T-stress * K-calibration curves * Stress intensity factor * Concrete fracture test Subject RIV: JL - Materials Fatigue, Friction Mechanics

  10. Flat Engineered Multichannel Reflectors

    Directory of Open Access Journals (Sweden)

    V. S. Asadchy

    2017-09-01

    Full Text Available Recent advances in engineered gradient metasurfaces have enabled unprecedented opportunities for light manipulation using optically thin sheets, such as anomalous refraction, reflection, or focusing of an incident beam. Here, we introduce a concept of multichannel functional metasurfaces, which are able to control incoming and outgoing waves in a number of propagation directions simultaneously. In particular, we reveal a possibility to engineer multichannel reflectors. Under the assumption of reciprocity and energy conservation, we find that there exist three basic functionalities of such reflectors: specular, anomalous, and retroreflections. Multichannel response of a general flat reflector can be described by a combination of these functionalities. To demonstrate the potential of the introduced concept, we design and experimentally test three different multichannel reflectors: three- and five-channel retroreflectors and a three-channel power splitter. Furthermore, by extending the concept to reflectors supporting higher-order Floquet harmonics, we forecast the emergence of other multichannel flat devices, such as isolating mirrors, complex splitters, and multi-functional gratings.

  11. Flat Engineered Multichannel Reflectors

    Science.gov (United States)

    Asadchy, V. S.; Díaz-Rubio, A.; Tcvetkova, S. N.; Kwon, D.-H.; Elsakka, A.; Albooyeh, M.; Tretyakov, S. A.

    2017-07-01

    Recent advances in engineered gradient metasurfaces have enabled unprecedented opportunities for light manipulation using optically thin sheets, such as anomalous refraction, reflection, or focusing of an incident beam. Here, we introduce a concept of multichannel functional metasurfaces, which are able to control incoming and outgoing waves in a number of propagation directions simultaneously. In particular, we reveal a possibility to engineer multichannel reflectors. Under the assumption of reciprocity and energy conservation, we find that there exist three basic functionalities of such reflectors: specular, anomalous, and retroreflections. Multichannel response of a general flat reflector can be described by a combination of these functionalities. To demonstrate the potential of the introduced concept, we design and experimentally test three different multichannel reflectors: three- and five-channel retroreflectors and a three-channel power splitter. Furthermore, by extending the concept to reflectors supporting higher-order Floquet harmonics, we forecast the emergence of other multichannel flat devices, such as isolating mirrors, complex splitters, and multi-functional gratings.

  12. Influence of mantle viscosity structure and mineral grain size on fluid migration pathways in the mantle wedge.

    Science.gov (United States)

    Cerpa, N. G.; Wada, I.; Wilson, C. R.; Spiegelman, M. W.

    2016-12-01

    We develop a 2D numerical porous flow model that incorporates both grain size distribution and matrix compaction to explore the fluid migration (FM) pathways in the mantle wedge. Melt generation for arc volcanism is thought to be triggered by slab-derived fluids that migrate into the hot overlying mantle and reduce its melting temperature. While the narrow location of the arcs relative to the top of the slab ( 100±30 km) is a robust observation, the release of fluids is predicted to occur over a wide range of depth. Reconciling such observations and predictions remains a challenge for the geodynamic community. Fluid transport by porous flow depends on the permeability of the medium which in turn depends on fluid fraction and mineral grain size. The grain size distribution in the mantle wedge predicted by laboratory derived laws was found to be a possible mechanism to focusing of fluids beneath the arcs [Wada and Behn, 2015]. The viscous resistance of the matrix to the volumetric strain generates compaction pressure that affects fluid flow and can also focus fluids towards the arc [Wilson et al, 2014]. We thus have developed a 2D one-way coupled Darcy's-Stokes flow model (solid flow independent of fluid flow) for the mantle wedge that combines both effects. For the solid flow calculation, we use a kinematic-dynamic approach where the system is driven by the prescribed slab velocity. The solid rheology accounts for both dislocation and diffusion creep and we calculate the grain size distribution following Wada and Behn [2015]. In our fluid flow model, the permeability of the medium is grain size dependent and the matrix bulk viscosity depends on solid shear viscosity and fluid fraction. The fluid influx from the slab is imposed as a boundary condition at the base of the mantle wedge. We solve the discretized governing equations using the software package TerraFERMA. Applying a range of model parameter values, including slab age, slab dip, subduction rate, and fluid

  13. Movement Features Which Describe the Flat Bench Press

    Directory of Open Access Journals (Sweden)

    Król Henryk

    2017-06-01

    Full Text Available Introduction. In sport technique studies, motion features can be useful as they have a certain defined measure [1]. In this work, we examined the following three features: the structure of the movement (all the characteristics of the movement, the fluency of the movement, and the rhythm of the movement. The aim of the study was to determine the usefulness of the selected movement features in the evaluation of the flat bench press. The protocol of the study included a flat bench press with free weights and a “touch-and-go” technique. Material and methods. The study involved twenty healthy men; however, only two were selected for analysis. The first subject was a 25-year-old powerlifter (body mass = 95 kg; body height = 182 cm; 1-RM in flat bench press = 145 kg. The second one was a 25-year-old bodybuilder (body mass = 77 kg; body height = 175 cm; 1-RM in flat bench press = 100 kg. The subjects performed consecutive sets of a single repetition of flat bench pressing with an increasing load (70, 80, 90, and 100% 1-RM, with the anticipated maximum weight, until the completion of one repetition maximum. Multidimensional movement analysis was made with the measuring system Smart-E (BTS, Italy, which consisted of six infrared cameras (120 Hz and a wireless module to measure muscle bioelectric activity (Pocket EMG. Results. It was demonstrated that the internal structure of the bench press performed by the bodybuilder and the powerlifter was different. As the time-history of barbell kinematics (the acceleration-time curve showed, with increased loading of the barbell, the rhythm of the flat bench press changed, and the fluidity of the movement worsened.

  14. Sub-crop geologic map of pre-Tertiary rocks in the Yucca Flat and northern Frenchman Flat areas, Nevada Test Site, southern Nevada

    Energy Technology Data Exchange (ETDEWEB)

    Cole, J.C.; Harris, A.G.; Wahl, R.R.

    1997-10-02

    This map displays interpreted structural and stratigraphic relations among the Paleozoic and older rocks of the Nevada Test Site region beneath the Miocene volcanic rocks and younger alluvium in the Yucca Flat and northern Frenchman Flat basins. These interpretations are based on a comprehensive examination and review of data for more than 77 drillholes that penetrated part of the pre-Tertiary basement beneath these post-middle Miocene structural basins. Biostratigraphic data from conodont fossils were newly obtained for 31 of these holes, and a thorough review of all prior microfossil paleontologic data is incorporated in the analysis. Subsurface relationships are interpreted in light of a revised regional geologic framework synthesized from detailed geologic mapping in the ranges surrounding Yucca Flat, from comprehensive stratigraphic studies in the region, and from additional detailed field studies on and around the Nevada Test Site. All available data indicate the subsurface geology of Yucca Flat is considerably more complicated than previous interpretations have suggested. The western part of the basin, in particular, is underlain by relics of the eastward-vergent Belted Range thrust system that are folded back toward the west and thrust by local, west-vergent contractional structures of the CP thrust system. Field evidence from the ranges surrounding the north end of Yucca Flat indicate that two significant strike-slip faults track southward beneath the post-middle Miocene basin fill, but their subsurface traces cannot be closely defined from the available evidence. In contrast, the eastern part of the Yucca Flat basin is interpreted to be underlain by a fairly simple north-trending, broad syncline in the pre-Tertiary units. Far fewer data are available for the northern Frenchman Flat basin, but regional analysis indicates the pre-Tertiary structure there should also be relatively simple and not affected by thrusting. This new interpretation has implications

  15. Sub-crop geologic map of pre-Tertiary rocks in the Yucca Flat and northern Frenchman Flat areas, Nevada Test Site, southern Nevada

    International Nuclear Information System (INIS)

    Cole, J.C.; Harris, A.G.; Wahl, R.R.

    1997-01-01

    This map displays interpreted structural and stratigraphic relations among the Paleozoic and older rocks of the Nevada Test Site region beneath the Miocene volcanic rocks and younger alluvium in the Yucca Flat and northern Frenchman Flat basins. These interpretations are based on a comprehensive examination and review of data for more than 77 drillholes that penetrated part of the pre-Tertiary basement beneath these post-middle Miocene structural basins. Biostratigraphic data from conodont fossils were newly obtained for 31 of these holes, and a thorough review of all prior microfossil paleontologic data is incorporated in the analysis. Subsurface relationships are interpreted in light of a revised regional geologic framework synthesized from detailed geologic mapping in the ranges surrounding Yucca Flat, from comprehensive stratigraphic studies in the region, and from additional detailed field studies on and around the Nevada Test Site. All available data indicate the subsurface geology of Yucca Flat is considerably more complicated than previous interpretations have suggested. The western part of the basin, in particular, is underlain by relics of the eastward-vergent Belted Range thrust system that are folded back toward the west and thrust by local, west-vergent contractional structures of the CP thrust system. Field evidence from the ranges surrounding the north end of Yucca Flat indicate that two significant strike-slip faults track southward beneath the post-middle Miocene basin fill, but their subsurface traces cannot be closely defined from the available evidence. In contrast, the eastern part of the Yucca Flat basin is interpreted to be underlain by a fairly simple north-trending, broad syncline in the pre-Tertiary units. Far fewer data are available for the northern Frenchman Flat basin, but regional analysis indicates the pre-Tertiary structure there should also be relatively simple and not affected by thrusting. This new interpretation has implications

  16. Low temperature dissolution creep induced B-type olivine fabric during serpentinization and deformation in mantle wedge

    Science.gov (United States)

    Liu, W.; Zhang, J.

    2017-12-01

    The B-type olivine fabric (i.e., the [010]ol axes subnormal to foliation and the [001]ol axes subparallel to the lineation) has been regarded as an important olivine fabric for interpreting global trench-parallel S-wave polarization in fore-arc regions. However, strong serpentinization and cold temperature environment in the mantle wedge should inhibit development of the B-type olivine fabric that requires high temperature to activate solid-state plastic deformation. Here we report fabrics of olivine and antigorite generated at low temperatures (300-370 oC) during serpentinization in a fossil mantle wedge of the Val Malenco area, Central Alps. Olivine in the serpentine matrix develops a pronounced B-type fabric, while antigorite in the same matrix displays a strong crystallographic orientation (CPO) with the (001) and the [010] subparallel to foliation and lineation, respectively. The following evidence leads to the conclusion that the B-type olivine fabric is resulted from dissolution creep assisted by grain boundaries sliding (GBS) and grain rotation, rather than solid-state plastic deformation: (1) serpentinization took place at low temperatures and a fluid-enriched environment, ideal for dissolution-precipitation creep; (2) the voids and zigzag boundaries along the interface between antigorite and olivine suggest a fluid dissolution reaction; (3) the primary coarse olivine develops a nearly random fabric, indicating the B-type fabrics in the fine-grained olivine can't be inherited fabrics. These results document for the first time the B-type olivine CPO formed by dissolution creep at low temperatures during serpentinization and provide a mechanism to reconcile petrofabric observations with geophysical observations of trench parallel fast S-wave seismic anisotropy in fore-arc mantle wedge regions.

  17. [Open-wedge osteotomy of the glenoid for treatment of posterior shoulder instability with increased glenoid retroversion].

    Science.gov (United States)

    Pogorzelski, J; Braun, S; Imhoff, A B; Beitzel, K

    2016-12-01

    Treatment of posterior shoulder instability with increased retroversion of the glenoid using open-wedge osteotomy of the glenoid neck stabilized with an autologous bone block. Symptomatic, atraumatic posterior shoulder instability with increased retroversion (>20°) of the glenoid and previously failed conservative or surgical treatment. General contraindications against surgery. Relative contraindications: osteoporosis, nicotine abuse, or suspected patient noncompliance. Posterior approach with a 7 cm long incision starting medial of the posterolateral corner of the acromion heading to the posterior axillary fold and subsequent preparation of the deltoid muscle and the infraspinatus muscle. The posterior glenohumeral capsule is incised by performing a capsular T‑shift. The osteotomy is performed intracapsulary medial to the genoid rim. The wedge bone graft, harvested from spina scapulae or iliac spine, is placed "press fit" in position. Additional fixation of the graft is not necessary if the anterior cortex is intact. For reinforcing the posterior capsule, a posterior capsule shift should be performed. Insertion of extracapsular wound drainage. Successive wound closure. Postoperative immobilization in a 0° shoulder orthesis for 6 weeks; avoidance of horizontal abduction for 8 weeks. After removing the wound drainage, start of limited active-assisted range of motion. Over-head sports after 6 months. From 2009-2015, 6 posterior open wedge glenoid osteotomies were performed. Postoperative retroversion of the glenoid was 11.2 ± 9.4° compared to 26.0 ± 8.6° before surgery. Of 6 shoulders, 2 showed postoperative signs of persistent posterior instability; the other 4 shoulders were free of complaints. No revision surgery was needed.

  18. Rocky Flats Cleanup Agreement implementation successes and challenges

    International Nuclear Information System (INIS)

    Shelton, D.C.

    1997-01-01

    On July 19, 1996 the US Department of Energy (DOE), State of Colorado (CDPHE), and US Environmental Protection Agency (EPA) entered into an agreement called the Rocky Flats Cleanup Agreement (RFCA) for the cleanup and closure of the Rocky Flats Environmental Technology Site (RFETS or Rocky Flats). Major elements of the agreement include: an Integrated Site-Wide Baseline; up to twelve significant enforceable milestones per year; agreed upon soil and water action levels and standards for cleanup; open space as the likely foreseeable land use; the plutonium and TRU waste removed by 2015; streamlined regulatory process; agreement with the Defense Nuclear Facilities Safety Board (DNFSB) to coordinate activities; and a risk reduction focus. Successful implementation of RFCA requires a substantial effort by the parties to change their way of thinking about RFETS and meet the deliverables and commitments. Substantial progress toward Site closure through the implementation of RFCA has been accomplished in the short time since the signing, yet much remains to be done. Much can be learned from the Rocky Flats experience by other facilities in similar situations

  19. Cosmic microwave background anisotropies in multiconnected flat spaces

    International Nuclear Information System (INIS)

    Riazuelo, Alain; Weeks, Jeffrey; Uzan, Jean-Philippe; Lehoucq, Roland; Luminet, Jean-Pierre

    2004-01-01

    This article investigates the signature of the seventeen multiconnected flat spaces in cosmic microwave background (CMB) maps. For each such space it recalls a fundamental domain and a set of generating matrices, and then goes on to find an orthonormal basis for the set of eigenmodes of the Laplace operator on that space. The basis eigenmodes are expressed as linear combinations of eigenmodes of the simply connected Euclidean space. A preceding work, which provides a general method for implementing multiconnected topologies in standard CMB codes, is then applied to simulate CMB maps and angular power spectra for each space. Unlike in the 3-torus, the results in most multiconnected flat spaces depend on the location of the observer. This effect is discussed in detail. In particular, it is shown that the correlated circles on a CMB map are generically not back to back, so that negative search of back-to-back circles in the Wilkinson Microwave Anisotropy Probe data does not exclude a vast majority of flat or nearly flat topologies

  20. Role of tidal flat in material cycling in the coastal sea

    OpenAIRE

    Yara, Yumiko; Yanagi, Tetsuo; Montani, Shigeru; Kuninao, Tada

    2007-01-01

    A simple tidal flat model with pelagic and benthic ecosystems was developed in order to analyze the nitrogen cycling in an inter-tidal flat of the Seto Inland Sea, Japan. After the verification of calculation results with the observed results in water quality and benthic biomasses, the role of this tidal flat in nitrogen cycling was evaluated from the viewpoint of water quality purification capability. When there is no suspension feeder in the tidal flat, the water quality purification capab...

  1. Holography and Entanglement in Flat Spacetime

    International Nuclear Information System (INIS)

    Li Wei; Takayanagi, Tadashi

    2011-01-01

    We propose a holographic correspondence of the flat spacetime based on the behavior of the entanglement entropy and the correlation functions. The holographic dual theory turns out to be highly nonlocal. We argue that after most part of the space is traced out, the reduced density matrix gives the maximal entropy and the correlation functions become trivial. We present a toy model for this holographic dual using a nonlocal scalar field theory that reproduces the same property of the entanglement entropy. Our conjecture is consistent with the entropy of Schwarzschild black holes in asymptotically flat spacetimes.

  2. Mussel beds are biological power stations on intertidal flats

    Science.gov (United States)

    Engel, Friederike G.; Alegria, Javier; Andriana, Rosyta; Donadi, Serena; Gusmao, Joao B.; van Leeuwe, Maria A.; Matthiessen, Birte; Eriksson, Britas Klemens

    2017-05-01

    Intertidal flats are highly productive areas that support large numbers of invertebrates, fish, and birds. Benthic diatoms are essential for the function of tidal flats. They fuel the benthic food web by forming a thin photosynthesizing compartment in the top-layer of the sediment that stretches over the vast sediment flats during low tide. However, the abundance and function of the diatom film is not homogenously distributed. Recently, we have realized the importance of bivalve reefs for structuring intertidal ecosystems; by creating structures on the intertidal flats they provide habitat, reduce hydrodynamic stress and modify the surrounding sediment conditions, which promote the abundance of associated organisms. Accordingly, field studies show that high chlorophyll a concentration in the sediment co-vary with the presence of mussel beds. Here we present conclusive evidence by a manipulative experiment that mussels increase the local biomass of benthic microalgae; and relate this to increasing biomass of microalgae as well as productivity of the biofilm across a nearby mussel bed. Our results show that the ecosystem engineering properties of mussel beds transform them into hot spots for primary production on tidal flats, highlighting the importance of biological control of sedimentary systems.

  3. Useful Solutions for Plane Wave Diffraction by Dielectric Slabs and Wedges

    Directory of Open Access Journals (Sweden)

    Gianluca Gennarelli

    2012-01-01

    Full Text Available This work presents an overview of available uniform asymptotic physical optics solutions for evaluating the plane wave diffraction by some canonical geometries of large interest: dielectric slabs and wedges. Such solutions are based on a physical optics approximation of the electric and magnetic equivalent surface currents in the involved scattering integrals. The resulting diffraction coefficients are expressed in terms of the geometrical optics response of the considered structure and the standard transition function of the Uniform Geometrical Theory of Diffraction. Numerical tests and comparisons make evident the effectiveness and reliability of the presented solutions.

  4. Thermodynamics and stability of flat anti-de Sitter black strings

    International Nuclear Information System (INIS)

    Chen Si; Schleich, Kristin; Witt, Donald M.

    2008-01-01

    We examine the thermodynamics and stability of 5-dimensional flat anti-de Sitter (AdS) black strings, locally asymptotically anti-de Sitter spacetimes whose spatial sections are AdS black holes with Ricci flat horizons. We find that there is a phase transition for the flat AdS black string when the AdS soliton string is chosen as the thermal background. We find that this bulk phase transition corresponds to a 4-dimensional flat AdS black hole to AdS soliton phase transition on the boundary Karch-Randall branes. We compute the possibility of a phase transition from a flat AdS black string to a 5-dimensional AdS soliton and show that, though possible for certain thin black strings, the transition to the AdS soliton string is preferred. In contrast to the case of the Schwarzschild-AdS black string, we find that the specific heat of the flat AdS black string is always positive; hence it is thermodynamically stable. We show numerically that both the flat AdS black string and AdS soliton string are free of a Gregory-Laflamme instability for all values of the mass parameter. Therefore thermodynamic stability implies perturbative stability for this spacetime. This may indicate that a generalization of the Gubser-Mitra conjecture, in which the assumption of a translational killing vector is weakened to that of a conformal killing vector of translational form, holds under certain conditions.

  5. Lower limit of strength wedge-type anchor bolts

    International Nuclear Information System (INIS)

    Arnedo Pena, A.; Frances Urmeneta, M.

    1998-01-01

    Simple expansion bolts, with a split expansion ring and a threaded bolt with an integral cone expander, called wedge type, are very used in securing and anchoring structures. The anchorage is obtained by a mechanism of torque-controlled expansion. Although less resistant than other types, its easy installation and low cost make them very competitive in light structures. In this paper, the minimum capacity values are analysed, when they are used to anchor safety-related equipment in NPP. The EPRI criteria developed in response to USI A-46 are applied and complemented by the new CEB Anchorage Design Guide. The results are compared with the information from european manufactures, adopting different safety factors for cracked and non-cracked concrete. With adequate control and inspection measures, including areas of noticeable cracking of concrete. minimum values for equipment can be obtained satisfying the strictest seismic validation requirements. (Author) 5 refs

  6. A New Triangular Flat Shell Element With Drilling Rotations

    DEFF Research Database (Denmark)

    Damkilde, Lars

    2008-01-01

    A new flat triangular shell element has been developed based on a newly developed triangular plate bending element by the author and a new triangular membrane element with drilling degrees of freedom. The advantage of the drilling degree of freedom is that no special precautions have to be made...... in connecting with assembly of elements. Due to the drilling rotations all nodal degrees of freedom have stiffness, and therefore no artificial suppression of degrees of freedom are needed for flat or almost flat parts of the shell structure....

  7. Piecewise flat gravitational waves

    NARCIS (Netherlands)

    van de Meent, M.

    2011-01-01

    We examine the continuum limit of the piecewise flat locally finite gravity model introduced by ’t Hooft. In the linear weak field limit, we find the energy–momentum tensor and metric perturbation of an arbitrary configuration of defects. The energy–momentum turns out to be restricted to satisfy

  8. Evidence of Arc Magma Genesis in a Paleo-Mantle Wedge, the Higashi-Akaishi Peridotite, Japan

    Science.gov (United States)

    Till, C. B.; Guild, M. R.; Grove, T. L.; Carlson, R. W.

    2014-12-01

    Located in the Sanbagawa subduction-related high-pressure metamorphic belt in SW Japan on the island of Shikoku, the Higashi-akaishi peridotite body is composed of dunite, lherzolite and garnet clinopyroxenite, interfingered in one locality with quartz-rich eclogite. Previous work indicates the P-T history of the peridotite includes rapid prograde metamorphism with peak temperatures of 700-810°C and pressures of 2.9-3.8 GPa [1] at ~88-89 Ma followed by rapid exhumation at >2.5 cm/yr [2,3]. Major and trace element and isotopic data from samples within the Higashi-akaishi peridotite presented here and in another recent study [4] provide a record of subduction zone melting processes in a paleo-mantle wedge. Ultramafic samples range from 40-52 wt.% SiO2, 1-11 wt.% Al2O3 and 21-45 wt.% MgO with olivine and clinopyroxene Mg#'s as high as 0.93. The quartz-rich eclogite contains 62 wt.% SiO2, 6 wt.% MgO and 13 wt.% Al2O3 with trace element concentrations that are enriched relative to the ultramafic samples. 87Sr/86Sr (.703237-.704288), 143Nd/144Nd (ɛNd=+2 to +6) and Pb isotopic compositions are within the range of previously studied Japanese arc rocks. We interpret the pyroxenites as shallowly crystallized cumulates with varying amounts of trapped hydrous melt and the harzburgites as residues of melting. The peak P-T conditions of these rocks are similar to the solidus conditions of H2O-saturated fertile mantle near the base of the mantle wedge [5,6]. The presence of garnet porphyroblasts that enclose primary euhedral chlorite together with the chemical evidence, suggest these samples are associated with mantle melting in the presence of H2O. Major element modeling suggests the quartz-rich eclogite composition can be reproduced through mixing melts of subducted sediment with wet peridotite melts in the mantle wedge. Thus the Higashi-aikashi rock suite provides an in-situ record of the beginnings of hydrous melting and the mechanisms of metasomatism in the mantle wedge

  9. Hepatic abscess versus peripheral cholangiocarcinoma: Sonographic differentiation

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hwan Hoon; Kim, Yun Hwan; Kang, Chang Ho; Chung, Kyoo Byung; Suh, Won Hyuck [Korea University College of Medicine, Seoul (Korea, Republic of); Lee, Chang Hee [Kunkuk University College of Medicine, Chung-Ju Hospital, Chung-Ju (Korea, Republic of)

    2000-12-15

    To find out the sonographic findings that are useful to differentiate hepatic abscess from peripheral cholangiocarcinoma. Twenty-two hepatic abscesses and 22 peripheral cholangiocarcinomas which had been confirmed histologically were included in this study. Objective points were echo characteristics of the lesion, internal septation, presence of peripheral low echoic rim, demarcation from normal liver(well or poorly defined), posterior enhancement, multiplicity, dilatation of bile duct(obstructive or non-obstructive), intrahepatic duct stone, pleural effusion, and intra-abdominal fluid collection. Echo characteristics of the lesion were classified in-to four types. Type I; Predominantly echogenic with hypoechoic portion, type II; Echogenic without hypoechoic portion, type III; Predominantly hypoechoic with echogenic portion, type IV; Hypoechoic without echogenic portion. 1)Nine abscesses and 2 peripheral cholangiocarcinomas were type I(p=0.037), 2)One abscess and 18 peripheral cholangiocarcinomas were type II(p=0.001), 3)Seven abscesses and none of peripheral cholangiocarcinomas were type III(p=0.001), 4)Five abscesses and 2 peripheral cholangiocarcinomas were type IV(p=0.410). Only 7 abscesses showed internal septations(p=0.013). One abscess and 9 peripheral cholangiocarcinomas showed peripheral hypoechoic halos(p=0.012). Only 9 peripheral cholangiocarcinomas showed obstructive bile duct dilatation (p=0.001). There were no statistically significant differences between abscess and peripheral cholangiocarcinoma on other objective points. Predominantly echogenic with hypoechoic portion, predominantly hypoechoic with echogenic portion, and internal septation are the features suggestive of hepatic abscess, and echogenic without hypoechoic portion, peripheral hypoechoic halo, obstructive bile duct dilatation are suggestive of peripheral cholangiocarcinoma. Therefore these sonographic findings are helpful to differentiate hepatic abscess from peripheral

  10. Design, Performance, and Calibration of CMS Hadron-Barrel Calorimeter Wedges

    CERN Document Server

    Baiatian, G; Emeliantchik, Igor; Massolov, V; Shumeiko, Nikolai; Stefanovich, R; Damgov, Jordan; Dimitrov, Lubomir; Genchev, Vladimir; Piperov, Stefan; Vankov, Ivan; Litov, Leander; Bencze, Gyorgy; Vesztergombi, Gyorgy; Zálán, Peter; Bawa, Harinder Singh; Beri, Suman Bala; Bhatnagar, Vipin; Kaur, Manjit; Kohli, Jatinder Mohan; Kumar, Arun; Singh, Jas Bir; Acharya, Bannaje Sripathi; Banerjee, Sunanda; Banerjee, Sudeshna; Chendvankar, Sanjay; Dugad, Shashikant; Kalmani, Suresh Devendrappa; Katta, S; Mazumdar, Kajari; Mondal, Naba Kumar; Nagaraj, P; Patil, Mandakini Ravindra; Reddy, L; Satyanarayana, B; Sudhakar, Katta; Verma, Piyush; Paktinat, S; Golutvin, Igor; Kalagin, Vladimir; Kosarev, Ivan; Mescheryakov, G; Sergeyev, S; Smirnov, Vitaly; Volodko, Anton; Zarubin, Anatoli; Gavrilov, Vladimir; Gershtein, Yuri; Kaftanov, Vitali; Kisselevich, I; Kolossov, V; Krokhotin, Andrey; Kuleshov, Sergey; Litvintsev, Dmitri; Stolin, Viatcheslav; Ulyanov, A; Demianov, A; Gribushin, Andrey; Kodolova, Olga; Petrushanko, Sergey; Sarycheva, Ludmila; Vardanyan, Irina; Yershov, A; Abramov, Victor; Goncharov, Petr; Khmelnikov, Alexander; Korablev, Andrey; Korneev, Yury; Krinitsyn, Alexander; Kryshkin, V; Lukanin, Vladimir; Pikalov, Vladimir; Ryazanov, Anton; Talov, Vladimir; Turchanovich, L; Volkov, Alexey; Camporesi, Tiziano; De Visser, Theo; Vlassov, E; Aydin, Sezgin; Dumanoglu, Isa; Eskut, Eda; Kayis-Topaksu, A; Kuzucu-Polatoz, A; Onengüt, G; Ozdes-Koca, N; Cankocak, Kerem; Ozok, Ferhat; Serin-Zeyrek, M; Sever, Ramazan; Zeyrek, Mehmet; Gülmez, Erhan; Isiksal, Engin; Kaya, Mithat; Ozkorucuklu, Suat; Levchuk, Leonid; Sorokin, Pavel; Grinev, B; Lubinsky, V; Senchishin, V; Anderson, E Walter; Hauptman, John M; Elias, John E; Elvira, D; Freeman, Jim; Green, Dan; Lazic, Dragoslav; Los, Serguei; O'Dell, Vivian; Ronzhin, Anatoly; Suzuki, Ichiro; Vidal, Richard; Whitmore, Juliana; Antchev, Georgy; Hazen, Eric; Lawlor, C; Machado, Emanuel; Posch, C; Rohlf, James; Wu, Shouxiang; Adams, Mark Raymond; Burchesky, Kyle; Qiang, W; Abdullin, Salavat; Baden, Drew; Bard, Robert; Eno, Sarah Catherine; Grassi, Tullio; Jarvis, Chad; Kellogg, Richard G; Kunori, Shuichi; Skuja, Andris; Podrasky, V; Sanzeni, Christopher; Winn, Dave; Akgun, Ugur; Ayan, S; Duru, Firdevs; Merlo, Jean-Pierre; Mestvirishvili, Alexi; Miller, Michael; Norbeck, Edwin; Olson, Jonathan; Onel, Yasar; Schmidt, Ianos; Akchurin, Nural; Carrell, Kenneth Wayne; Gumu, K; Thomas, Ray; Baarmand, Marc M; Ralich, Robert; Vodopiyanov, Igor; Cushman, Priscilla; Heering, Arjan Hendrix; Sherwood, Brian; Cremaldi, Lucien Marcus; Reidy, Jim; Sanders, David A; Karmgard, Daniel John; Ruchti, Randy; Fisher, Wade Cameron; Mans, Jeremy; Tully, Christopher; De Barbaro, Pawel; Bodek, Arie; Budd, Howard; Chung, Yeon Sei; Haelen, T; Imboden, Matthias; Hagopian, Sharon; Hagopian, Vasken; Johnson, Kurtis F; Barnes, Virgil E; Laasanen, Alvin T; Pompos, Arnold

    2007-01-01

    Extensive measurements have been made with pions, electrons and muons on four production wedges of the Compact Muon Solenoid (CMS) hadron barrel (HB) calorimeter in the H2 beam line at CERN with particle momenta varying from 20 to 300 GeV/c. Data were taken both with and without a prototype electromagnetic lead tungstate crystal calorimeter (EB) in front of the hadron calorimeter. The time structure of the events was measured with the full chain of preproduction front-end electronics running at 34 MHz. Moving-wire radioactive source data were also collected for all scintillator layers in the HB. These measurements set the absolute calibration of the HB prior to first pp collisions to approximately 4%.

  11. Measuring and modeling exposure from environmental radiation on tidal flats

    International Nuclear Information System (INIS)

    Gould, T.J.; Hess, C.T.

    2005-01-01

    To examine the shielding effects of the tide cycle, a high pressure ion chamber was used to measure the exposure rate from environmental radiation on tidal flats. A theoretical model is derived to predict the behavior of exposure rate as a function of time for a detector placed one meter above ground on a tidal flat. The numerical integration involved in this derivation results in an empirical formula which implies exposure rate ∝tan-1(sint). We propose that calculating the total exposure incurred on a tidal flat requires measurements of only the slope of the tidal flat and the exposure rate when no shielding occurs. Experimental results are consistent with the model

  12. Polonium-210 in marine bivalves inhabiting a wedge bank region, South India

    International Nuclear Information System (INIS)

    Feroz Khan, M.; Godwin Wesley, S.; Rajan, M.P.

    2013-01-01

    Determination of background radiation dose-rate is important in the process of assessing risks to the environment from exposure to living organisms both in terms of deriving the incremental dose-rate and as a point of reference for evaluating the significance of the exposure level. In the present study, 210 Po was quantified in two species of bivalve mollusks commonly available from so called a 'wedge bank region' of southern tip of India. Based on the activity concentration in media and in the whole body, an external and internal dose rate assessment to green mussel Perna viridis and brown mussel Perna indica due to 210 Po was derived using ERICA assessment tool. The samples were collected at the intertidal region along the wedge bank region of southern tip of India during 2009 to 2010. The measurement contributes to a better knowledge of these elements, since no data exists in this region. 5-10 g of each tissue sample was wet-digested using 70% concentrated HNO 3 followed by the addition of 40% H 2 O 2 along with 20 8Po tracer (0.2 Bq). The normality of the data set was checked using Lilliefors test (ne''50) and potential outliers, if any, were tested using Walsh's test (n>60). Using the measured 210 Po activity in molluscs, sediments and seawater, dose assessment was performed using the Tier 2 ERICA environment dose assessment tool 1.0

  13. Open-wedge osteotomy using an internal plate fixator in patients with medial-compartment gonarthritis and varus malalignment

    DEFF Research Database (Denmark)

    Niemeyer, Philipp; Schmal, Hagen; Hauschild, Oliver

    2010-01-01

    PURPOSE: Our purpose was to evaluate the 3-year clinical results of patients with medial-compartment osteoarthritis of the knee and varus malalignment who underwent open-wedge high tibial osteotomy (HTO) with an internal plate fixator (TomoFix; Synthes, Solothurn, Switzerland). Clinical results a...

  14. Angular-momentum-dominated electron beams and flat-beam generation

    International Nuclear Information System (INIS)

    Sun, Yin-e

    2005-01-01

    In the absence of external forces, if the dynamics within an electron beam is dominated by its angular momentum rather than other effects such as random thermal motion or self Coulomb-repulsive force (i.e., space-charge force), the beam is said to be angular-momentum-dominated. Such a beam can be directly applied to the field of electron-cooling of heavy ions; or it can be manipulated into an electron beam with large transverse emittance ratio, i.e., a flat beam. A flat beam is of interest for high-energy electron-positron colliders or accelerator-based light sources. An angular-momentum-dominated beam is generated at the Fermilab/NICADD photoinjector Laboratory (FNPL) and is accelerated to an energy of 16 MeV. The properties of such a beam is investigated systematically in experiment. The experimental results are in very good agreement with analytical expectations and simulation results. This lays a good foundation for the transformation of an angular-momentum-dominated beam into a flat beam. The round-to-flat beam transformer is composed of three skew quadrupoles. Based on a good knowledge of the angular-momentum-dominated beam, the quadrupoles are set to the proper strengths in order to apply a total torque which removes the angular momentum, resulting in a flat beam. For bunch charge around 0.5 nC, an emittance ratio of 100 ± 5 was measured, with the smaller normalized root-mean-square emittance around 0.4 mm-mrad. Effects limiting the flat-beam emittance ratio are investigated, such as the chromatic effects in the round-to-flat beam transformer, asymmetry in the initial angular-momentum-dominated beam, and space-charge effects. The most important limiting factor turns out to be the uncorrelated emittance growth caused by space charge when the beam energy is low, for example, in the rf gun area. As a result of such emittance growth prior to the round-to-flat beam transformer, the emittance ratio achievable in simulation decreases from orders of thousands to

  15. Angular-momentum-dominated electron beams and flat-beam generation

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Yin-e [Univ. of Chicago, IL (United States)

    2005-06-01

    In the absence of external forces, if the dynamics within an electron beam is dominated by its angular momentum rather than other effects such as random thermal motion or self Coulomb-repulsive force (i.e., space-charge force), the beam is said to be angular-momentum-dominated. Such a beam can be directly applied to the field of electron-cooling of heavy ions; or it can be manipulated into an electron beam with large transverse emittance ratio, i.e., a flat beam. A flat beam is of interest for high-energy electron-positron colliders or accelerator-based light sources. An angular-momentum-dominated beam is generated at the Fermilab/NICADD photoinjector Laboratory (FNPL) and is accelerated to an energy of 16 MeV. The properties of such a beam is investigated systematically in experiment. The experimental results are in very good agreement with analytical expectations and simulation results. This lays a good foundation for the transformation of an angular-momentum-dominated beam into a flat beam. The round-to-flat beam transformer is composed of three skew quadrupoles. Based on a good knowledge of the angular-momentum-dominated beam, the quadrupoles are set to the proper strengths in order to apply a total torque which removes the angular momentum, resulting in a flat beam. For bunch charge around 0.5 nC, an emittance ratio of 100 ± 5 was measured, with the smaller normalized root-mean-square emittance around 0.4 mm-mrad. Effects limiting the flat-beam emittance ratio are investigated, such as the chromatic effects in the round-to-flat beam transformer, asymmetry in the initial angular-momentum-dominated beam, and space-charge effects. The most important limiting factor turns out to be the uncorrelated emittance growth caused by space charge when the beam energy is low, for example, in the rf gun area. As a result of such emittance growth prior to the round-to-flat beam transformer, the emittance ratio achievable in simulation decreases from orders of thousands to

  16. Increase in Bacterial Colony Formation from a Permafrost Ice Wedge Dosed with a Tomitella biformata Recombinant Resuscitation-Promoting Factor Protein.

    Science.gov (United States)

    Puspita, Indun Dewi; Kitagawa, Wataru; Kamagata, Yoichi; Tanaka, Michiko; Nakatsu, Cindy H

    2015-01-01

    Resuscitation-promoting factor (Rpf) is a protein that has been found in a number of different Actinobacteria species and has been shown to promote the growth of active cells and resuscitate dormant (non-dividing) cells. We previously reported the biological activity of an Rpf protein in Tomitella biformata AHU 1821(T), an Actinobacteria isolated from a permafrost ice wedge. This protein is excreted outside the cell; however, few studies have investigated its contribution in environmental samples to the growth or resuscitation of bacteria other than the original host. Therefore, the aim of the present study was to determine whether Rpf from T. biformata impacted the cultivation of other bacteria from the permafrost ice wedge from which it was originally isolated. All experiments used recombinant Rpf proteins produced using a Rhodococcus erythropolis expression system. Dilutions of melted surface sterilized ice wedge samples mixed with different doses of the purified recombinant Rpf (rRpf) protein indicated that the highest concentration tested, 1250 pM, had a significantly (p permafrost sediments. The results of the present study demonstrated that rRpf not only promoted the growth of T. biformata from which it was isolated, but also enhanced colony formation by another Actinobacteria in an environmental sample.

  17. Nonflat equilibrium liquid shapes on flat surfaces.

    Science.gov (United States)

    Starov, Victor M

    2004-01-15

    The hydrostatic pressure in thin liquid layers differs from the pressure in the ambient air. This difference is caused by the actions of surface forces and capillary pressure. The manifestation of the surface force action is the disjoining pressure, which has a very special S-shaped form in the case of partial wetting (aqueous thin films and thin films of aqueous electrolyte and surfactant solutions, both free films and films on solid substrates). In thin flat liquid films the disjoining pressure acts alone and determines their thickness. However, if the film surface is curved then both the disjoining and the capillary pressures act simultaneously. In the case of partial wetting their simultaneous action results in the existence of nonflat equilibrium liquid shapes. It is shown that in the case of S-shaped disjoining pressure isotherm microdrops, microdepressions, and equilibrium periodic films exist on flat solid substrates. Criteria are found for both the existence and the stability of these nonflat equilibrium liquid shapes. It is shown that a transition from thick films to thinner films can go via intermediate nonflat states, microdepressions and periodic films, which both can be more stable than flat films within some range of hydrostatic pressure. Experimental investigations of shapes of the predicted nonflat layers can open new possibilities of determination of disjoining pressure in the range of thickness in which flat films are unstable.

  18. FLAT FEET OF DHE CHILDREN IN PRE-SCHOOL AGE

    Directory of Open Access Journals (Sweden)

    Admira Koničanin

    2011-03-01

    Full Text Available Subjekt : Of this research are flat feet of the children of both sexes in pre-school age children Aim : Of the research is confirm wheter is exists or flat feel of the children of both sexes in pre-school age.

  19. Ricci-flat branes

    International Nuclear Information System (INIS)

    Brecher, D.; Perry, M.J.

    2000-01-01

    Up to overall harmonic factors, the D8-brane solution of the massive type IIA supergravity theory is the product of nine-dimensional Minkowski space (the world-volume) with the real line (the transverse space). We show that the equations of motion allow for the world-volume metric to be generalised to an arbitrary Ricci-flat one. If this nine-dimensional Ricci-flat manifold admits Killing spinors, then the resulting solutions are supersymmetric and satisfy the usual Bogomol'nyi bound, although they preserve fewer than the usual one half of the supersymmetries. We describe the possible choices of such manifolds, elaborating on the connection between the existence of Killing spinors and the self-duality condition on the curvature two-form. Since the D8-brane is a domain wall in ten dimensions, we are led to consider the general case: domain walls in any supergravity theory. Similar considerations hold here also. Moreover, it is shown that the world-volume of any magnetic brane - of which the domain walls are a specific example - can be generalised in precisely the same way. The general class of supersymmetric solutions have gravitational instantons as their spatial sections. Some mention is made of the world-volume solitons of such branes

  20. Land claim and loss of tidal flats in the Yangtze Estuary.

    Science.gov (United States)

    Chen, Ying; Dong, Jinwei; Xiao, Xiangming; Zhang, Min; Tian, Bo; Zhou, Yunxuan; Li, Bo; Ma, Zhijun

    2016-04-01

    Tidal flats play a critical role in supporting biodiversity and in providing ecosystem services but are rapidly disappearing because of human activities. The Yangtze Estuary is one of the world's largest alluvial estuaries and is adjacent to the most developed economic zone in China. Using the Yangtze Estuary as a study region, we developed an automatic algorithm to estimate tidal flat areas based on the Land Surface Water Index and the Normalized Difference Vegetation Index. The total area of tidal flats in the Yangtze Estuary has decreased by 36% over the past three decades, including a 38% reduction in saltmarshes and a 31% reduction in barren mudflats. Meanwhile, land claim has accumulated to 1077 km(2), a value that exceeds the area of the remaining tidal flats. We divided the Yangtze Estuary into Shanghai and Jiangsu areas, which differ in riverine sediment supply and tidal flat management patterns. Although land claim has accelerated in both areas, the decline in tidal flat area has been much greater in Jiangsu than in Shanghai because of abundant supplies of sediment and artificial siltation in the latter area. The results highlight the need for better coastal planning and management based on tidal flat dynamics.

  1. Flat directions in flipped SU(5). I: All-order analysis

    Energy Technology Data Exchange (ETDEWEB)

    Cleaver, G.B. E-mail: gcleaver@rainbow.physics.tamu.edu; Ellis, J. E-mail: john.ellis@cern.ch; Nanopoulos, D.V. E-mail: dimitri@soda.physics.tamu.edu

    2001-04-23

    We present a systematic classification of field directions for the string-derived flipped SU(5) model that are D- and F-flat to all orders. Properties of the flipped SU(5) model with field values in these directions are compared to those associated with other flat directions that have been shown to be F-flat to specific finite orders in the superpotential. We discuss the phenomenological Higgs spectrum, and quark and charged-lepton mass textures.

  2. Flat Directions in Flipped SU(5); 1, All-Order Analysis

    CERN Document Server

    Cleaver, G B; Nanopoulos, Dimitri V

    2001-01-01

    We present a systematic classification of field directions for the string-derived flipped SU(5) model that are D- and F-flat to all orders. Properties of the flipped SU(5) model with field values in these directions are compared to those associated with other flat directions that have been shown to be F-flat to specific finite orders in the superpotential. We discuss the phenomenological Higgs spectrum, and quark and charged-lepton mass textures.

  3. Rigidity of complete noncompact bach-flat n-manifolds

    Science.gov (United States)

    Chu, Yawei; Feng, Pinghua

    2012-11-01

    Let (Mn,g) be a complete noncompact Bach-flat n-manifold with the positive Yamabe constant and constant scalar curvature. Assume that the L2-norm of the trace-free Riemannian curvature tensor R∘m is finite. In this paper, we prove that (Mn,g) is a constant curvature space if the L-norm of R∘m is sufficiently small. Moreover, we get a gap theorem for (Mn,g) with positive scalar curvature. This can be viewed as a generalization of our earlier results of 4-dimensional Bach-flat manifolds with constant scalar curvature R≥0 [Y.W. Chu, A rigidity theorem for complete noncompact Bach-flat manifolds, J. Geom. Phys. 61 (2011) 516-521]. Furthermore, when n>9, we derive a rigidity result for R<0.

  4. Design scenarios for flat panel photobioreactors

    International Nuclear Information System (INIS)

    Slegers, P.M.; Wijffels, R.H.; Straten, G. van; Boxtel, A.J.B. van

    2011-01-01

    Evaluation of the potential of algae production for biofuel and other products at various locations throughout the world requires assessment of algae productivity under varying light conditions and different reactor layouts. A model was developed to predict algae biomass production in flat panel photobioreactors using the interaction between light and algae growth for the algae species Phaeodactylum tricornutum and Thalassiosira pseudonana. The effect of location, variable sunlight and reactor layout on biomass production in single standing and parallel positioned flat panels was considered. Three latitudes were studied representing the Netherlands, France and Algeria. In single standing reactors the highest yearly biomass production is achieved in Algeria. During the year biomass production fluctuates the most in the Netherlands, while it is almost constant in Algeria. Several combinations of path lengths and biomass concentrations can result in the same optimal biomass production. The productivity in parallel place flat panels is strongly influenced by shading and diffuse light penetration between the panels. Panel orientation has a large effect on productivity and at higher latitudes the difference between north-south and east-west orientation may go up to 50%.

  5. Quality assurance technique for absorbed dose distribution in external radiation therapy with non-physical wedges in consideration of the character of the imaging plate

    International Nuclear Information System (INIS)

    Fujibuchi, Toshioh; Fujisaki, Tatsuya; Kurokawa, Masayuki; Sakae, Takeji

    2011-01-01

    The film dose distribution method is used for profile measurements of non-physical wedges, because three-dimensional automatic control water phantoms cannot be used. Recently, many hospitals have adopted computed radiography (CR) systems in preference to automatic developing processors and films. This may allow use of automatic processors to be discontinued. In this study, a beam was irradiated to an Imaging Plate (IP), and then IP was exposed to a fixed amount of light with fading, and we then measured the off-center ratio (OCR) absorbed dose distribution in external radiation therapy with non-physical wedge. This was compared with the OCR measured with an ionization chamber dosimeter. It was consequently possible for IP to approximate the value measured by the ionization chamber dosimeter by using a metal filter. This method offers a simple quality assurance technique for absorbed dose distribution in external radiation therapy with non-physical wedges in consideration of the character of the IP. (author)

  6. Graphene nanoribbons production from flat carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Melo, W. S.; Guerini, S.; Diniz, E. M., E-mail: eduardo.diniz@ufma.br [Departamento de Física, Universidade Federal do Maranhão, São Luís - MA 65080-805 (Brazil)

    2015-11-14

    Graphene nanoribbons are of great interest for pure and applied sciences due to their unique properties which depend on the nanoribbon edges, as, for example, energy gap and antiferromagnetic coupling. Nevertheless, the synthesis of nanoribbons with well-defined edges remains a challenge. To collaborate with this subject, here we propose a new route for the production of graphene nanoribbons from flat carbon nanotubes filled with a one-dimensional chain of Fe atoms by first principles calculations based on density functional theory. Our results show that Fe-filled flat carbon nanotubes are energetically more stable than non flattened geometries. Also we find that by hydrogenation or oxygenation of the most curved region of the Fe-filled flat armchair carbon nanotube, it occurred a spontaneous production of zigzag graphene nanoribbons which have metallic or semiconducting behavior depending on the edge and size of the graphene nanoribbon. Such findings can be used to create a new method of synthesis of regular-edge carbon nanoribbons.

  7. Graphene nanoribbons production from flat carbon nanotubes

    International Nuclear Information System (INIS)

    Melo, W. S.; Guerini, S.; Diniz, E. M.

    2015-01-01

    Graphene nanoribbons are of great interest for pure and applied sciences due to their unique properties which depend on the nanoribbon edges, as, for example, energy gap and antiferromagnetic coupling. Nevertheless, the synthesis of nanoribbons with well-defined edges remains a challenge. To collaborate with this subject, here we propose a new route for the production of graphene nanoribbons from flat carbon nanotubes filled with a one-dimensional chain of Fe atoms by first principles calculations based on density functional theory. Our results show that Fe-filled flat carbon nanotubes are energetically more stable than non flattened geometries. Also we find that by hydrogenation or oxygenation of the most curved region of the Fe-filled flat armchair carbon nanotube, it occurred a spontaneous production of zigzag graphene nanoribbons which have metallic or semiconducting behavior depending on the edge and size of the graphene nanoribbon. Such findings can be used to create a new method of synthesis of regular-edge carbon nanoribbons

  8. Flat-response x-ray-diode-detector development

    International Nuclear Information System (INIS)

    Tirsell, G.

    1982-10-01

    In this report we discuss the design of an improved sub-nanosecond flat response x-ray diode detector needed for ICF diagnostics. This device consists of a high Z cathode and a complex filter tailored to flatten the response so that the total x-ray energy below 1.5 keV can be measured using a single detector. Three major problems have become evident as a result of our work with the original LLNL design including deviation from flatness due to a peak in the response below 200 eV, saturation at relatively low x-ray fluences, and long term gold cathode instability. We are investigating grazing incidence reflection to reduce the response below 200 eV, new high Z cathode materials for long term stability, and a new complex filter for improved flatness. Better saturation performance will require a modified XRD detector under development with reduced anode to cathode spacing and increased anode bias voltage

  9. Peripheral visual performance enhancement by neurofeedback training.

    Science.gov (United States)

    Nan, Wenya; Wan, Feng; Lou, Chin Ian; Vai, Mang I; Rosa, Agostinho

    2013-12-01

    Peripheral visual performance is an important ability for everyone, and a positive inter-individual correlation is found between the peripheral visual performance and the alpha amplitude during the performance test. This study investigated the effect of alpha neurofeedback training on the peripheral visual performance. A neurofeedback group of 13 subjects finished 20 sessions of alpha enhancement feedback within 20 days. The peripheral visual performance was assessed by a new dynamic peripheral visual test on the first and last training day. The results revealed that the neurofeedback group showed significant enhancement of the peripheral visual performance as well as the relative alpha amplitude during the peripheral visual test. It was not the case in the non-neurofeedback control group, which performed the tests within the same time frame as the neurofeedback group but without any training sessions. These findings suggest that alpha neurofeedback training was effective in improving peripheral visual performance. To the best of our knowledge, this is the first study to show evidence for performance improvement in peripheral vision via alpha neurofeedback training.

  10. Fluids confined in wedges and by edges: From cluster integrals to thermodynamic properties referred to different regions

    International Nuclear Information System (INIS)

    Urrutia, Ignacio

    2015-01-01

    Recently, new insights into the relation between the geometry of the vessel that confines a fluid and its thermodynamic properties were traced through the study of cluster integrals for inhomogeneous fluids. In this work, I analyze the thermodynamic properties of fluids confined in wedges or by edges, emphasizing on the question of the region to which these properties refer. In this context, the relations between the line-thermodynamic properties referred to different regions are derived as analytic functions of the dihedral angle α, for 0 < α < 2π, which enables a unified approach to both edges and wedges. As a simple application of these results, I analyze the properties of the confined gas in the low-density regime. Finally, using recent analytic results for the second cluster integral of the confined hard sphere fluid, the low density behavior of the line thermodynamic properties is analytically studied up to order two in the density for 0 < α < 2π and by adopting different reference regions

  11. Mussel beds are biological power stations on intertidal flats

    NARCIS (Netherlands)

    Engel, Friederike G.; Alegria, Javier; Andriana, Rosyta; Donadi, Serena; Gusmao, Joao B.; van Leeuwe, Maria A.; Matthiessen, Birte; Eriksson, Britas Klemens

    2017-01-01

    Intertidal flats are highly productive areas that support large numbers of invertebrates, fish, and birds. Benthic diatoms are essential for the function of tidal flats. They fuel the benthic food web by forming a thin photosynthesizing compartment in the top-layer of the sediment that stretches

  12. High tibial closing wedge osteotomy for medial compartment osteoarthrosis of knee

    Directory of Open Access Journals (Sweden)

    Tuli S

    2008-01-01

    Full Text Available Background: Most patients of symptomatic osteoarthrosis of knee are associated with varus malalignment that is causative or contributory to painful arthrosis. It is rational to correct the malalignment to transfer the functional load to the unaffected or less affected compartment of the knee to relieve symptoms. We report the outcome of a simple technique of high tibial osteotomy in the medial compartment of osteoarthrosis of the knee. Materials and Methods: Between 1996 and 2004 we performed closing wedge osteotomy in 78 knees in 65 patients. The patients selected for osteotomy were symptomatic essentially due to medial compartment osteoarthrosis associated with moderate genu varum. Of the 19 patients who had bilateral symptomatic disease 11 opted for high tibial osteotomy of their second knee 1-3 years after the first operation. Preoperative grading of osteoarthrosis and postoperative function was assessed using Japanese Orthopaedic Association (JOA rating scale. Results: At a minimum follow-up of 2 years (range 2-9 years 6-10° of valgus correction at the site of osteotomy was maintained, there was significant relief of pain while walking, negotiating stairs, squatting and sitting cross-legged. Walking distance in all patients improved by two to four times their preoperative distance of 200-400 m. No patient lost any preoperative knee function. The mean JOA scoring improved from preoperative 54 (40-65 to 77 (55-85 at final follow-up. Conclusion: Closing wedge high tibial osteotomy performed by our technique can be undertaken in any setup with moderate facilities. Operation related complications are minimal and avoidable. Kirschner wire fixation is least likely to interfere with replacement surgery if it becomes necessary.

  13. Nonconformally flat initial data for binary compact objects

    International Nuclear Information System (INIS)

    Uryu, Koji; Limousin, Francois; Gourgoulhon, Eric; Friedman, John L.; Shibata, Masaru

    2009-01-01

    A new method is described for constructing initial data for a binary neutron-star system in quasiequilibrium circular orbit. Two formulations for nonconformally flat data, waveless and near-zone helically symmetric, are introduced; in each formulation, the Einstein-Euler system, written in 3+1 form on an asymptotically flat spacelike hypersurface, is exactly solved for all metric components, including the spatially nonconformally flat potentials, and for irrotational flow. A numerical method applicable to both formulations is explained with an emphasis on the imposition of a spatial gauge condition. Results are shown for solution sequences of irrotational binary neutron-stars with matter approximated by parametrized equations of state that use a few segments of polytropic equations of state. The binding energy and total angular momentum of solution sequences computed within the conformally flat--Isenberg-Wilson-Mathews--formulation are closer to those of the third post-Newtonian (3PN) two point particles up to the closest orbits, for the more compact stars, whereas sequences resulting from the waveless/near-zone helically symmetric formulations deviate from the 3PN curve even more for the sequences with larger compactness. We think it likely that this correction reflects an overestimation in the Isenberg-Wilson-Mathews formulation as well as in the 3PN formula, by ∼1 cycle in the gravitational-wave phase during the last several orbits. The work suggests that imposing spatial conformal flatness results in an underestimate of the quadrupole deformation of the components of binary neutron-star systems in the last few orbits prior to merger.

  14. The surgery of peripheral nerves (including tumors)

    DEFF Research Database (Denmark)

    Fugleholm, Kåre

    2013-01-01

    Surgical pathology of the peripheral nervous system includes traumatic injury, entrapment syndromes, and tumors. The recent significant advances in the understanding of the pathophysiology and cellular biology of peripheral nerve degeneration and regeneration has yet to be translated into improved...... surgical techniques and better outcome after peripheral nerve injury. Decision making in peripheral nerve surgery continues to be a complex challenge, where the mechanism of injury, repeated clinical evaluation, neuroradiological and neurophysiological examination, and detailed knowledge of the peripheral...... nervous system response to injury are prerequisite to obtain the best possible outcome. Surgery continues to be the primary treatment modality for peripheral nerve tumors and advances in adjuvant oncological treatment has improved outcome after malignant peripheral nerve tumors. The present chapter...

  15. "Flat-Fish" vacuum chamber for the ISR

    CERN Multimedia

    CERN PhotoLab

    1983-01-01

    The "Flat-Fish" vacuum chamber was a very special one for the ISR beam intersection I-4, inside the Split-Field Magnet. Technical descriptions are given with pictures 7802042 and 7712182. There were several generations of this chamber. This picture was taken during the last year of ISR operation. See also 7510230X, 7511123X, 7802039, 7802041. A flat-fish type vacuum chamber was also used at I-8, inside the Open Axial Field Magnet (OAFM, experiment 807 on large transverse momentum collision products), see 7901358.

  16. Peripheral Circulatory Features during High-Frequency Jet Ventilation

    Directory of Open Access Journals (Sweden)

    M. B. Kontorovich

    2010-01-01

    Full Text Available The paper gives the results of a study of peripheral circulatory features during high-frequency jet ventilation (HFJV. The main specific features of peripheral circulation and oxygen transport during HFJV are formulated on the basis of a study of cardiac output (impedance cardiography, peripheral vascular resistance, peripheral vascular blood filling (photoplethysmogram analysis, adaptive peripheral blood flow reactions (spectral analysis of peripheral vascular pulsation. HFJV gives rise to the peculiar pattern of peripheral hemodynamics and tissue gas exchange, which is characterized by higher oxygen uptake without a decrease in mixed venous blood saturation, with normal extraction coefficient and preserved low peripheral vascular resistance. During HFJV, unlike traditional ventilation, the main peripheral hemodynamic feature is the increased capillary bed blood volume caused by the blood flow involvement of reserve capillaries under control of volume (parasympathetic regulation of adaptive peripheral hemodynamic reactions. Key words: high-frequency jet ventilation, oxygen transport, peripheral hemodynamics.

  17. Sandbox rheometry: Co-evolution of stress and strain in Riedel- and Critical Wedge-experiments

    Science.gov (United States)

    Ritter, Malte C.; Santimano, Tasca; Rosenau, Matthias; Leever, Karen; Oncken, Onno

    2018-01-01

    Analogue sandbox experiments have been used for a long time to understand tectonic processes, because they facilitate detailed measurements of deformation at a spatio-temporal resolution unachievable from natural data. Despite this long history, force measurements to further characterise the mechanical evolution in analogue sandbox experiments have only emerged recently. Combined continuous measurements of forces and deformation in such experiments, an approach here referred to as "sandbox rheometry", are a new tool that may help to better understand work budgets and force balances for tectonic systems and to derive constitutive laws for regional scale deformation. In this article we present an experimental device that facilitates precise measurements of boundary forces and surface deformation at high temporal and spatial resolution. We demonstrate its capabilities in two classical experiments: one of strike-slip deformation (the Riedel set-up) and one of compressional accretionary deformation (the Critical Wedge set-up). In these we are able to directly observe a correlation between strain weakening and strain localisation that had previously only been inferred, namely the coincidence of the maximum localisation rate with the onset of weakening. Additionally, we observe in the compressional experiment a hysteresis of localisation with respect to the mechanical evolution that reflects the internal structural complexity of an accretionary wedge.

  18. A new GTD slope diffraction coefficient for plane wave illumination of a wedge

    DEFF Research Database (Denmark)

    Lumholt, Michael; Breinbjerg, Olav

    1997-01-01

    Two wedge problems including slope diffraction are solved: one in which the incident field is a non-uniform plane wave, and one in which it is an inhomogeneous plane wave. The two solutions lead to the same GTD slope diffraction coefficient. This coefficient reveals the existence of a coupling...... effect between a transverse magnetic (or transverse electric) incident plane wave and the transverse electric (or transverse magnetic) slope-diffracted field. The coupling effect is not described by the existing GTD slope diffraction coefficient...

  19. Laser illuminated flat panel display

    Energy Technology Data Exchange (ETDEWEB)

    Veligdan, J.T.

    1995-12-31

    A 10 inch laser illuminated flat panel Planar Optic Display (POD) screen has been constructed and tested. This POD screen technology is an entirely new concept in display technology. Although the initial display is flat and made of glass, this technology lends itself to applications where a plastic display might be wrapped around the viewer. The display screen is comprised of hundreds of planar optical waveguides where each glass waveguide represents a vertical line of resolution. A black cladding layer, having a lower index of refraction, is placed between each waveguide layer. Since the cladding makes the screen surface black, the contrast is high. The prototype display is 9 inches wide by 5 inches high and approximately I inch thick. A 3 milliwatt HeNe laser is used as the illumination source and a vector scanning technique is employed.

  20. Radial and Azimuthal Anisotropy Tomography of the NE Japan Subduction Zone: Implications for the Pacific Slab and Mantle Wedge Dynamics

    Science.gov (United States)

    Ishise, Motoko; Kawakatsu, Hitoshi; Morishige, Manabu; Shiomi, Katsuhiko

    2018-05-01

    We investigate slab and mantle structure of the NE Japan subduction zone from P wave azimuthal and radial anisotropy using travel time tomography. Trench normal E-W-trending azimuthal anisotropy (AA) and radial anisotropy (RA) with VPV > VPH are found in the mantle wedge, which supports the existence of small-scale convection in the mantle wedge with flow-induced LPO of mantle minerals. In the subducting Pacific slab, trench parallel N-S-trending AA and RA with VPH > VPV are obtained. Considering the effect of dip of the subducting slab on apparent anisotropy, we suggest that both characteristics can be explained by the presence of laminar structure, in addition to AA frozen-in in the subducting plate prior to subduction.

  1. Wedge Splitting Test and Inverse Analysis on Fracture Behaviour of Fiber Reinforced and Regular High Performance Concretes

    DEFF Research Database (Denmark)

    Hodicky, Kamil; Hulin, Thomas; Schmidt, Jacob Wittrup

    2014-01-01

    The fracture behaviour of three fiber reinforced and regular HPC (high performance concretes) is presented in this paper. Two mixes are based on optimization of HPC whereas the third mix was a commercial mix developed by CONTEC ApS (Denmark). The wedge splitting test setup with 48 cubical specimens...

  2. Flat-rate tax systems and their effect on labor markets

    OpenAIRE

    Peichl, Andreas

    2014-01-01

    The potential economic outcomes resulting from a flat rate of income tax have been the subject of an ongoing academic and political debate. Many observers have suggested that the introduction of a flat tax would be beneficial for a country’s economy, having a positive influence on the labor market and the gross domestic product by enhancing incentives to work, save, invest, and take risks. A flat tax also significantly simplifies income taxation which increases tax compliance and reduces ta...

  3. Optimised intake stroke analysis for flat and dome head pistons ...

    African Journals Online (AJOL)

    Optimised intake stroke analysis for flat and dome head pistons. ... in understanding the performance characteristics optioned between flat head and dome head pistons in engine design. ... EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT

  4. A meta-analysis into the effect of lateral-wedged insoles with subtalar strapping versus traditional insoles in adults with medial knee osteoarthritis.

    Directory of Open Access Journals (Sweden)

    L. Duvenhage

    2011-02-01

    Full Text Available To  systematically  identify,  collate,  and  analyze  the  current available evidence  for  the  effectiveness  of  lateral-wedged  insoles,  with subtalar strapping,  on  reducing  pain,  improving  function  and  improving  the femoral-tibial  angle  (FTA,  in  adults  with  medial  knee osteoarthritis compared to traditional insoles without subtalar strapping.Six computerised databases, namely Cochrane Library, CiNAHL, PEDro, BIOMED central,  PubMed  and  ScienceDirect  were  searched. The  included articles were  then  all  rated  using  the  PEDro  scale  to  determine  their meth-odological quality.  Homogeneous data were pooled in a meta-analysis using Review Manager (REVMAN software.  Where statistical pooling of the results was not possible, findings were summarised in narrative form. Three randomised controlled trials were selected for this review. The average PEDro score was 5.7. A meta-analysis demonstrated that lateral-wedged insoles with subtalar strapping significantly reduced pain in the short-term (p=0.004. The review found that lateral-wedge insoles with subtalar strapping significantly decreased pain in the short-term and seemed to have a positive effect on the FTA in the long-term, when compared to traditional insoles without  subtalar strapping. The lateral-wedge insole with subtalar strapping may provide a financially feasible adjunctive self-management treatment for knee OA and should be considered before invasive procedures such as surgery.

  5. B-type olivine fabric induced by low temperature dissolution creep during serpentinization and deformation in mantle wedge

    Science.gov (United States)

    Liu, Wenlong; Zhang, Junfeng; Barou, Fabrice

    2018-01-01

    The B-type olivine fabric (i.e., the [010] axes subnormal to foliation and the [001] axes subparallel to the lineation) has been regarded as an important olivine fabric for interpreting global trench-parallel S-wave polarization in fore-arc regions. However, strong serpentinization and cold temperature environment in the mantle wedge should inhibit development of the B-type olivine fabric that requires high temperature to activate solid-state plastic deformation. Here we report fabrics of olivine and antigorite generated at low temperatures (300-370 °C) during serpentinization in a fossil mantle wedge of the Val Malenco area, Central Alps. Olivine in the serpentine matrix develops a pronounced B-type fabric, while antigorite in the same matrix displays a strong crystallographic preferred orientation (CPO) with the (001) planes and the [010] axes subparallel to foliation and lineation, respectively. The following evidence leads to the conclusion that the B-type olivine fabric results from dissolution creep assisted by grain boundary sliding (GBS) and grain rotation, rather than solid-state plastic deformation: (1) serpentinization took place at low temperatures and a fluid-enriched environment, ideal for dissolution-precipitation creep; (2) the voids and zigzag boundaries along the interface between antigorite and olivine suggest a fluid dissolution reaction; (3) the primary coarse olivine develops a nearly random fabric, indicating the B-type fabrics in the fine-grained olivine may not be inherited fabrics. These results document for the first time the B-type olivine CPO formed by dissolution creep at low temperatures during serpentinization and provide a mechanism to reconcile petrofabric observations with geophysical observations of trench parallel fast S-wave seismic anisotropy in fore-arc mantle wedge regions.

  6. Flat directions in left-right symmetric string derived models

    International Nuclear Information System (INIS)

    Cleaver, Gerald B.; Clements, David J.; Faraggi, Alon E.

    2002-01-01

    The only string models known to reproduce the minimal supersymmetric standard model in the low energy effective field theory are those constructed in the free fermionic formulation. We demonstrate the existence of quasirealistic free fermionic heterotic string models in which supersymmetric singlet flat directions do not exist. This raises the possibility that supersymmetry is broken perturbatively in such models by the one-loop Fayet-Iliopoulos term. We show, however, that supersymmetric flat directions that utilize vacuum expectation values of some non-Abelian fields in the massless string spectrum do exist in the model. We argue that hidden sector condensates lift the flat directions and break supersymmetry hierarchically

  7. Flat rotation curves using scalar-tensor theories

    Energy Technology Data Exchange (ETDEWEB)

    Cervantes-Cota, Jorge L [Depto de Fisica, Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 D.F. (Mexico); RodrIguez-Meza, M A [Depto de Fisica, Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 D.F. (Mexico); Nunez, Dario [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, A.P. 70-543, 04510 D.F. (Mexico)

    2007-11-15

    We computed flat rotation curves from scalar-tensor theories in their weak field limit. Our model, by construction, fits a flat rotation profile for velocities of stars. As a result, the form of the scalar field potential and DM distribution in a galaxy are determined. By taking into account the constraints for the fundamental parameters of the theory ({lambda}, {alpha}), it is possible to obtain analytical results for the density profiles. For positive and negative values of {alpha}, the DM matter profile is as cuspy as NFW's.

  8. Stress analyses of flat plates with attached nozzles. Vol. 2: Experimental stress analyses of a flat plate with one nozzle attached

    International Nuclear Information System (INIS)

    Battiste, R.L.; Peters, W.H.; Ranson, W.F.; Swinson, W.F.

    1975-07-01

    Vol. 1 of this report compares experimental results with theoretical stress distributions for a flat plate with one nozzle configuration and for a flat plate with two closely spaced nozzles attached. This volume contains the complete test results for a flat plate with one nozzle attached that was subjected to 1:1 and 1:2 biaxial planar loadings on the plate, to a thrust loading on the nozzle, and to a moment loading on the nozzle. The plate tested was 36 x 36 x 0.375 in., and the attached nozzle had an outer dia of 2.625 in. and a 0.250-in.-thick wall. The nozzle was located in the center of the plate and was considered to be free of weld distortions and irregularities in the junction area. (U.S.)

  9. Infarction and Laceration of Liver Parenchyma Caused by Wedged CO2 Venography Before TIPS Insertion

    International Nuclear Information System (INIS)

    Theuerkauf, Ingo; Strunk, Holger; Brensing, Karl August; Schild, Hans Heinz; Pfeifer, Ulrich

    2001-01-01

    We describe the fatal outcome of an elective TIPS procedure performed in a 43-year-old man with alcoholic cirrhosis. Wedged hepatic venography with CO 2 was the reason for infarction and laceration of liver parenchyma resulting in a subcapsular hematoma and subsequent intra-abdominal bleeding. This is the first report of this complication after the use of CO 2 in a cirrhotic patient

  10. Relationship between flexible flat foot and developmental hip dysplasia.

    Science.gov (United States)

    Ponce de León Samper, M C; Herrera Ortiz, G; Castellanos Mendoza, C

    2015-01-01

    To evaluate the possible relationship between flexible flat foot and developmental hip dysplasia in children between six and 15 years of age. Cross-sectional study including 65 patients that had undergone surgery due to residual hip dysplasia or hip dislocation and compared against 75 healthy patients. Flexible flat foot prevalence was measured in each group, with the results showing that 61% of the group with residual hip dysplasia or hip dislocation had this condition, vs. 12% in the healthy group. The statistical analysis shows that the chances of suffering from flexible flat foot, are five times greater in the hip dysplasia or hip dislocation group, than in the healthy group. There is no evidence in the literature showing a relationship between these two conditions, even though they have a common etiology. This study shows a potential measurable relation between this two conditions. Patients with hip dysplasia or dislocation may have a higher chance of presenting flexible flat foot during late childhood, adolescence and adulthood, a fact that suggests a relationship between these two pathologies. Also, patients who seek assistance for the first time because of a flexible flat foot condition without having been evaluated during the first year of life for hip dysplasia, would be better off if evaluated for residual hip dysplasia. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.

  11. A new algorithm for finite element simulation of wedge osteotomies in voxel models with application to the tibia

    Directory of Open Access Journals (Sweden)

    Thomas Pressel

    2010-01-01

    Full Text Available Thomas Pressel1, Markus D Schofer1, Jörg Meiforth2, Markus Lengsfeld1, Jan Schmitt11Department of Orthopaedics and Rheumatology, University Hospital Marburg, Marburg, Germany; 2St. Vincentius Kliniken, Klinik für Orthopädie, Karlsruhe, GermanyAbstract: Wedge osteotomies are used to correct bone deformities or change the forces acting on bones and joints in the human body. Finite element models can be employed to simulate the effect of such operations on the bone or adjacent joints. The automatic generation of voxel models derived from computed tomography data is a common procedure, but the major drawback of the method lies in irregular model surfaces. Therefore, the concept of hybrid models combining voxel and tetrahedron meshes was developed. We present an algorithm to simulate wedge osteotomies in voxel models by adding tetrahedron to brick elements. Applicability of the procedure was tested by performing a parametric study using a tibia model created from computed tomography scans taken in vivo applying individually calculated force conditions. The osteotomy angle largely affected maximum stresses: at 2.5 degrees valgus, the stresses at the medial and lateral tibial plateau were equivalent, while increasing valgus angles reduced medial stresses. The algorithm described here is an improvement of former mesh generation procedures and allows a better representation of the geometry at the osteotomy level. The algorithm can be used for all wedge osteotomies and is not limited to the tibia.Keywords: finite element/osteotomy/voxel/pre-operative planning, simulation, mesh algorithm

  12. A systematic review and meta-analysis into the effect of lateral wedge arch support insoles for reducing knee joint load in patients with medial knee osteoarthritis

    Science.gov (United States)

    Xing, Fei; Lu, Bin; Kuang, Ming-jie; Wang, Ying; Zhao, Yun-long; Zhao, Jie; Sun, Lei; Wang, Yan; Ma, Jian-xiong; Ma, Xin-long

    2017-01-01

    Abstract Objective: The aim of this study was to evaluate the immediate effects of lateral wedge arch support insoles (LWAS) on reducing the knee joint load in patients with medial knee osteoarthritis (OA) compared with an appropriate control. Methods: Databases including Medline, EMBASE, Web of Science, Wiley Online Library, Cochrane library, and Google Scholar were searched with no limits on study date or language, from the earliest available date to October 31, 2016. The included studies had to have the aim of reducing knee load and have an appropriate control. The main measured values were the first and second peak external knee adduction moments (EKAM) and the knee adduction angular impulse (KAAI). The random-effects model was used for analyzing the eligible studies. Results: Nine studies met the inclusion criteria with a total of 356 participants of whom 337 received LWAS treatment. The risk of methodological bias scores (quality index) ranged from 21 to 27 of 32. Treatment with LWAS resulted in statistically significant reductions in the first peak EKAM (P = .005), the second peak EKAM (P = .01), and the KAAI (P = .03). However, among trials in which the control treatment was control shoes, the LWAS showed no associations on the first peak EKAM (P = .10) or the KAAI (P =  .06); among trials in which the control treatment was neutral insoles, the LWAS showed no associations on the second peak EKAM (P = .21) or the KAAI (P = .23). At the same time, the LWAS showed no statistically significant reduction on the first peak EKAM (P = .39) when compared with flat insoles. Conclusion: Although meta-analysis outcomes of all studies indicated statistically significant associations between LWAS and reductions of the first peak EKAM, second peak EKAM and KAAI in people with medial knee OA while walking, different results existed in subgroups using various control conditions for comparison. These findings do not support the use of LWAS

  13. 75 FR 12981 - Eligibility for Commercial Flats Failing Deflection

    Science.gov (United States)

    2010-03-18

    ... applicable only to automation flats, for all commercial flat-size mail except saturation and high-density...[supreg] pricing. If automation prices are denied, pieces that are prepared to be part of full-service IMb... compliance, but at additional cost; and quarter-folding would not work well with any inserts. Also, there was...

  14. Deconvolving the wedge: maximum-likelihood power spectra via spherical-wave visibility modelling

    Science.gov (United States)

    Ghosh, A.; Mertens, F. G.; Koopmans, L. V. E.

    2018-03-01

    Direct detection of the Epoch of Reionization (EoR) via the red-shifted 21-cm line will have unprecedented implications on the study of structure formation in the infant Universe. To fulfil this promise, current and future 21-cm experiments need to detect this weak EoR signal in the presence of foregrounds that are several orders of magnitude larger. This requires extreme noise control and improved wide-field high dynamic-range imaging techniques. We propose a new imaging method based on a maximum likelihood framework which solves for the interferometric equation directly on the sphere, or equivalently in the uvw-domain. The method uses the one-to-one relation between spherical waves and spherical harmonics (SpH). It consistently handles signals from the entire sky, and does not require a w-term correction. The SpH coefficients represent the sky-brightness distribution and the visibilities in the uvw-domain, and provide a direct estimate of the spatial power spectrum. Using these spectrally smooth SpH coefficients, bright foregrounds can be removed from the signal, including their side-lobe noise, which is one of the limiting factors in high dynamics-range wide-field imaging. Chromatic effects causing the so-called `wedge' are effectively eliminated (i.e. deconvolved) in the cylindrical (k⊥, k∥) power spectrum, compared to a power spectrum computed directly from the images of the foreground visibilities where the wedge is clearly present. We illustrate our method using simulated Low-Frequency Array observations, finding an excellent reconstruction of the input EoR signal with minimal bias.

  15. Peripherally applied opioids for postoperative pain

    DEFF Research Database (Denmark)

    Nielsen, B N; Henneberg, S W; Schmiegelow, K

    2015-01-01

    BACKGROUND: Opioids applied peripherally at the site of surgery may produce postoperative analgesia with few side effects. We performed this systematic review to evaluate the analgesic effect of peripherally applied opioids for acute postoperative pain. METHODS: We searched PubMed (1966 to June...... 2013), Embase (1980 to June 2013), and the Cochrane Central Register of Controlled Trials (The Cochrane Library 2013, Issue 6). Randomized controlled trials investigating the postoperative analgesic effect of peripherally applied opioids vs. systemic opioids or placebo, measured by pain intensity...... difference -5 mm, 95% CI: -7 to -3) for peripherally applied opioids vs. placebo and statistically significant increased time to first analgesic (mean difference 153 min, 95% CI: 41-265). When preoperative inflammation was reported (five studies), peripherally applied opioids significantly improved...

  16. Radiographic evaluation of 19 patients with Paprosky 3A and 3B submitted to acetabular review with trabecular metal wedge

    Directory of Open Access Journals (Sweden)

    Carlos Eduardo Benvindo Rosal da Fonseca Neto

    Full Text Available ABSTRACT Objective: This study is aimed at evaluating the fixation of trabecular metal wedges in patients who underwent revision of total hip arthroplasty with large acetabular bone defects. Methods: The radiographs of 19 patients (21 hips, who underwent revision of total hip arthroplasty using trabecular metal wedges from September 2010 to December 2014 were evaluated. This study included only cases of Paprosky 3A and 3B. Preoperative and postoperative images were analyzed. Non-fixation of the implant was defined by the presence of angular variation of the component higher 10 degrees or displacement greater than 6 mm. Patients with follow-up times of less than 24 months or who did not attend the last two appointments were excluded from the study. Results: The mean follow-up time was 39.4 months (25-61. Fixation was achieved in all cases despite its complexity. There was only one case of dislocation that was treated with open reduction. One case developed infection, and was surgically approached on two occasions, with extensive debridement and intravenous antibiotics following protocol, with good evolution. Conclusion: The implanted trabecular metal wedges showed excellent results in the short- and medium-term and may represent another option in the reconstruction of large acetabular defects, sometimes replacing bone reconstruction that uses bone tissue banks or autologous graft.

  17. Prevalence of Flat Foot: Comparison between Male and Female Primary School Students

    Directory of Open Access Journals (Sweden)

    Reihaneh Askary Kachoosangy

    2013-10-01

    Full Text Available Objectives: The aim of this study was to determine the prevalence of flat foot in a population of 7-12 year old students and to investigate the relationship between flat foot and age and sex. Methods: In this cross-sectional study, a total of 945 students (460 girls and 485 boys were examined. The presence of flatfoot and the degree of its severity according to Tachdjian's system of grading for flatfoot was assessed. Results: The data showed that the overall prevalence of flat foot was 74% out of which 23% were mild, 34% were moderate and 17% were severe. The prevalence of flat foot in girl and boy students were 75.2% and 72.6% respectively, but this difference was not significant. Moreover, no significant relationship was observed between the prevalence of flat foot and age. Discussion: This study showed that flat foot is a common problem among primary school students and should be addressed by responsible organizations.

  18. A structural multidisciplinary approach to depression management in nursing-home residents: a multicentre, stepped-wedge cluster-randomised trial

    NARCIS (Netherlands)

    Leontjevas, R.; Gerritsen, D.L.; Smalbrugge, M.; Teerenstra, S.; Vernooij-Dassen, M.J.F.J.; Koopmans, R.T.C.M.

    2013-01-01

    BACKGROUND: Depression in nursing-home residents is often under-recognised. We aimed to establish the effectiveness of a structural approach to its management. METHODS: Between May 15, 2009, and April 30, 2011, we undertook a multicentre, stepped-wedge cluster-randomised trial in four provinces of

  19. Detection of elevated pulmonary capillary wedge pressure in elderly patients with various cardiac disorders by the Valsalva manoeuvre.

    NARCIS (Netherlands)

    Remmen, J.J.; Aengevaeren, W.R.M.; Verheugt, F.W.A.; Jansen, R.W.M.M.

    2006-01-01

    In the present study, we assessed whether elevated (> or =15 mmHg) PCWP (pulmonary capillary wedge pressure) can be detected using the blood pressure response to the Valsalva manoeuvre in a group of elderly patients with various cardiac disorders, including atrial fibrillation and valvular heart

  20. Higher-spin flat space cosmologies with soft hair

    Energy Technology Data Exchange (ETDEWEB)

    Ammon, Martin [Theoretisch-Physikalisches Institut, Friedrich-Schiller University of Jena, Max-Wien-Platz 1, D-07743 Jena (Germany); Grumiller, Daniel [Institute for Theoretical Physics, TU Wien, Wiedner Hauptstrasse 8-10/136, A-1040 Vienna (Austria); CMCC-Universidade Federal do ABC,Santo André, S.P. (Brazil); Prohazka, Stefan [Institute for Theoretical Physics, TU Wien, Wiedner Hauptstrasse 8-10/136, A-1040 Vienna (Austria); Riegler, Max [Université libre de Bruxelles, Boulevard du Triomphe, Campus de la Plaine,1050 Bruxelles (Belgium); Wutte, Raphaela [Institute for Theoretical Physics, TU Wien, Wiedner Hauptstrasse 8-10/136, A-1040 Vienna (Austria)

    2017-05-08

    We present and discuss near horizon boundary conditions for flat space higher-spin gravity in three dimensions. As in related work our boundary conditions ensure regularity of the solutions independently of the charges. The asymptotic symmetry algebra is given by a set of û(1) current algebras. The associated charges generate higher-spin soft hair. We derive the entropy for solutions that are continuously connected to flat space cosmologies and find the same result as in the spin-2 case: the entropy is linear in the spin-2 zero-mode charges and independent from the spin-3 charges. Using twisted Sugawara-like constructions of higher-spin currents we show that our simple result for entropy of higher-spin flat space cosmologies coincides precisely with the complicated earlier results expressed in terms of higher-spin zero mode charges.

  1. Half-flat structures on S3×S3

    DEFF Research Database (Denmark)

    Madsen, Thomas Bruun; Salamon, Simon

    We classify left-invariant half-flat SU(3)-structures on S3 × S3, using the representation theory of SO(4) and matrix algebra. This leads to a systematic study of the associated cohomogeneity one Ricci-flat metrics with holonomy G2 obtained on 7-manifolds with equidistant S3 × S3 hypersurfaces...

  2. Design study of flat belt CVT for electric vehicles

    Science.gov (United States)

    Kumm, E. L.

    1980-01-01

    A continuously variable transmission (CVT) was studied, using a novel flat belt pulley arrangement which couples the high speed output shaft of an energy storage flywheel to the drive train of an electric vehicle. A specific CVT arrangement was recommended and its components were selected and sized, based on the design requirements of a 1700 KG vehicle. A design layout was prepared and engineering calculations made of component efficiencies and operating life. The transmission efficiency was calculated to be significantly over 90% with the expected vehicle operation. A design consistent with automotive practice for low future production costs was considered, together with maintainability. The technology advancements required to develop the flat belt CVT were identified and an estimate was made of how the size of the flat belt CVT scales to larger and smaller design output torques. The suitability of the flat belt CVT for alternate application to an electric vehicle powered by an electric motor without flywheel and to a hybrid electric vehicle powered by an electric motor with an internal combustion engine was studied.

  3. Burn-related peripheral neuropathy: A systematic review.

    Science.gov (United States)

    Tu, Yiji; Lineaweaver, William C; Zheng, Xianyou; Chen, Zenggan; Mullins, Fred; Zhang, Feng

    2017-06-01

    Peripheral neuropathy is the most frequent disabling neuromuscular complication of burns. However, the insidious and progressive onset of burn neuropathy makes it often undiagnosed or overlooked. In our study, we reviewed the current studies on the burn-related peripheral neuropathy to summarize the morbidity, mechanism, detecting method and management of peripheral neuropathy in burn patients. Of the 1533 burn patients included in our study, 98 cases (6.39%) were presented with peripheral neuropathy. Thermal and electrical burns were the most common etiologies. Surgical procedures, especially nerve decompression, showed good effect on functional recovery of both acute and delayed peripheral neuropathy in burn patients. It is noteworthy that, for early detection and prevention of peripheral neuropathy, electrodiagnostic examinations should be performed on burn patients independent of symptoms. Still, the underlying mechanisms of burn-related peripheral neuropathy remain to be clarified. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  4. Structure and tectonic evolution of the southwestern Trinidad dome, Escambray complex, Central Cuba: Insights into deformation in an accretionary wedge

    Science.gov (United States)

    Despaigne-Díaz, Ana Ibis; García Casco, Antonio; Cáceres Govea, Dámaso; Wilde, Simon A.; Millán Trujillo, Guillermo

    2017-10-01

    The Trinidad dome, Escambray complex, Cuba, forms part of an accretionary wedge built during intra-oceanic subduction in the Caribbean from the Late Cretaceous to Cenozoic. The structure reflects syn-subduction exhumation during thickening of the wedge, followed by extension. Field mapping, metamorphic and structural analysis constrain the tectonic evolution into five stages. Three ductile deformation events (D1, D2 and D3) are related to metamorphism in a compressional setting and formation of several nappes. D1 subduction fabrics are only preserved as relict S1 foliation and rootless isoclinal folds strongly overprinted by the main S2 foliation. The S2 foliation is parallel to sheared serpentinised lenses that define tectonic contacts, suggesting thrust stacks and underthrusting at mantle depths. Thrusting caused an inverted metamorphic structure with higher-grade on top of lower-grade nappes. Exhumation started during D2 when the units were incorporated into the growing accretionary wedge along NNE-directed thrust faults and was accompanied by substantial decompression and cooling. Folding and thrusting continued during D3 and marks the transition from ductile to brittle-ductile conditions at shallower crustal levels. The D4-5 events are related to extension and contributed to the final exhumation (likely as a core complex). D4 is associated with a regional spaced S4 cleavage, late open folds, and numerous extension veins, whereas D5 is recorded by normal and strike-slip faults affecting all nappes. The P-t path shows rapid exhumation during D2 and slower rates during D3 when the units were progressively incorporated into the accretionary prism. The domal shape formed in response to tectonic denudation assisted by normal faulting and erosion at the surface during the final stages of structural development. These results support tectonic models of SW subduction of the Proto-Caribbean crust under the Caribbean plate during the latest Cretaceous and provide

  5. Flat out and bluesome

    OpenAIRE

    Wilson, Mark; Snaebjornsdottir, Bryndis; Byatt, Lucy

    2008-01-01

    ‘Nanoq: flat out and bluesome’ is the story of polar bears, the largest land predators on earth, and their journey from the arctic wilderness to the museums and stately homes of the UK. The work documents the histories of each of these bears, the legacies of the hunters who shot them and the skills and expertise of the taxidermists who stuffed them.

  6. The Development of the Flat-Knitted Shaped Uppers based on Ergonomics

    Directory of Open Access Journals (Sweden)

    Lu Zhiwen

    2016-06-01

    Full Text Available To achieve the efficiency and specification of the flat-knitted uppers design, the basic patterns of uppers are made from shoe lasts based on the research on the characteristics of human’s feet and wearability requirements on uppers. The knitting technology for half-shaped and fully shaped uppers was formed after the shear deformation of basic pattern and combination with flat knitting technology. As regards to the functional requirements on key parts of uppers, the structures of flat-knitted shaped uppers were intensively analysed and studied, dividing them into two categories (functional structure and decorative structure, discussing the knitting methods and advantages of different structure, and finally experimentally proving that the planar pattern of flat knitted uppers can apply to the design of flat-knitted uppers and achieve the combination of functionality and artistry of sneakers after combining with structural changes, with a great significance on the achievement of the efficient production of uppers and the enhancement of its commercial value.

  7. The rocky flats controversy on radionuclide soil action levels

    International Nuclear Information System (INIS)

    Earle, T.C.

    2004-01-01

    This report describes the Rocky Flats radionuclide soil action level controversy as a case study for the purpose of understanding the nature and value of stakeholder involvement in the management of radiological hazards. The report consists of three main sections. The first section outlines the Rocky Flats story, including the Cold War era, the post-Cold War era, and the transition between the two. This provides the context necessary to understand the radionuclide soil action level controversy, the main events of which are described in the second section. In the final section, the Rocky Flats case is briefly discussed within the framework of a general model of stakeholder involvement and the lessons learned from the case are identified. (author)

  8. STRENGTHENING THE ROLE OF GOVERNMENT IN RESOLVING FRAUD AND DISPUTES OF THE FLAT MANAGEMENT

    Directory of Open Access Journals (Sweden)

    Situmorang P.

    2018-03-01

    Full Text Available The public concern with the housing issues and conditions including flat management becomes current phenomenon in developing countries such as Indonesia. However, less attention has been paid by researchers to discuss the role of government in the flat management. The fact is that fraud and disputes often occur as a result of the management of flats such as management fees and monthly billing invoice becoming the main issue at the court. Through case law approach method with four different cases, this paper therefore captures several issues related to the management of flats. For instance, this paper discusses a case where flat management companies tend to increase maintenance fees without having a consent or agreement, both from owners and tenants. Disputes are also related to transparency of collected management fees by flat management companies, causing dissatisfaction from the owners and tenants. Hence, this paper suggests that there is the need of government’s role in the flat management issues. This suggestion is relevant to the idea of exercising government’s power through monitoring flat management companies in order to comply with flat legislation. This paper argues that the use of government’s authority could be practised through monitoring system and setting up administrative procedure on the management of flats.

  9. The interplay between wetting and phase behaviour in binary polymer films and wedges: Monte Carlo simulations and mean field calculations

    International Nuclear Information System (INIS)

    Mueller, M; Binder, K

    2005-01-01

    By confining a binary mixture, one can profoundly alter its miscibility behaviour. The qualitative features of miscibility in confined geometry are rather universal and are shared by polymer mixtures as well as small molecules, but the unmixing transition in the bulk and the wetting transition are typically well separated in polymer blends. We study the interplay between wetting and miscibility of a symmetric polymer mixture via large scale Monte Carlo simulations in the framework of the bond fluctuation model and via numerical self-consistent field calculations. The film surfaces interact with the monomers via short-ranged potentials, and the wetting transition of the semi-infinite system is of first order. It can be accurately located in the simulations by measuring the surface and interface tensions and using Young's equation. If both surfaces in a film attract the same component, capillary condensation occurs and the critical point is close to the critical point of the bulk. If surfaces attract different components, an interface localization/delocalization occurs which gives rise to phase diagrams with two critical points in the vicinity of the pre-wetting critical point of the semi-infinite system. The crossover between these two types of phase diagrams as a function of the surface field asymmetry is studied. We investigate the dependence of the phase diagram on the film width Δ for antisymmetric surface fields. Upon decreasing the film width the two critical points approach the symmetry axis of the phase diagram, and below a certain width, Δ tri , there remains only a single critical point at symmetric composition. This corresponds to a second order interface localization/delocalization transition even though the wetting transition is of first order. At a specific film width, Δ tri , tricritical behaviour is found. The behaviour of antisymmetric films is compared with the phase behaviour in an antisymmetric double wedge. While the former is the analogy of

  10. Morphodynamic Modeling of Tidal Mud Flats

    National Research Council Canada - National Science Library

    Winterwerp, Johan C

    2008-01-01

    The objective of the current research proposal is to develop and test a numerical model to simulate and predict the seasonal morphodynamic evolution of intertidal mud flats in macrotidal environments...

  11. Liposomal bupivacaine versus bupivacaine/epinephrine after video-assisted thoracoscopic wedge resection†.

    Science.gov (United States)

    Parascandola, Salvatore A; Ibañez, Jessica; Keir, Graham; Anderson, Jacqueline; Plankey, Michael; Flynn, Deanna; Cody, Candice; De Marchi, Lorenzo; Margolis, Marc; Blair Marshall, M

    2017-06-01

    The purpose of this research is to compare liposomal bupivacaine and bupivacaine/epinephrine for intercostal blocks related to analgesic use and length of stay following video-assisted thoracoscopic wedge resection. A retrospective study of patients undergoing video-assisted thoracoscopic wedge resection from 2010 to 2015 was performed. We selected patients who stayed longer than 24 h in hospital. Primary outcomes were length of stay and postoperative analgesic use at 12-h intervals from 24 to 72 h. Intercostal blocks were performed with liposomal bupivacaine in 62 patients and bupivacaine/epinephrine in 51 patients. A Wilcoxon signed-rank test evaluated differences in median postoperative analgesic use and length of stay. Those who received liposomal bupivacaine consumed fewer analgesics than those who received bupivacaine/epinephrine, with a statistically significant difference from 24 to 36 h (20.25 vs 45.0 mg; P  = 0.0059) and from 60 to 72 h postoperatively (15.0 vs 33.75 mg; P  = 0.0350). In patients who stayed longer than 72 h, the median cumulative analgesic consumption in those who received liposomal bupivacaine was statistically significantly lower than those who received bupivacaine/epinephrine (120.0 vs 296.5 mg; P  = 0.0414). Median length of stay for the liposomal bupivacaine and bupivacaine/epinephrine groups were 45:05 h and 44:29 h, respectively. There were no adverse events related to blocks performed with liposomal bupivacaine. Thoracic surgery patients who have blocks performed with liposomal bupivacaine require fewer analgesics postoperatively. This may decrease complications related to poor pain control and decrease side effects related to narcotic use in our patient population. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  12. Checks for quality control of wedge dynamics in treatment units and the planning system; Verificaciones para control de calidad de la cuna dinamica en las unidades de tratamiento y el sistema de planificacion

    Energy Technology Data Exchange (ETDEWEB)

    Mateos Salvador, P.; Rodriguez Lopez, B.; Font Gelabert, J.; Hernandez Rodriguez, J.; Arino Gil, A.

    2013-07-01

    The objective of this study is to verify the implementation of enhanced dynamic wedge (EDW) vary in the Eclipse planning system and the experimental determination of the parameters that define the dosimetry characteristics of enhanced dynamic wedge of our treatment units. (Author)

  13. Reduced knee joint loading with lateral and medial wedge insoles for management of knee osteoarthritis: a protocol for a randomized controlled trial.

    Science.gov (United States)

    Lewinson, Ryan T; Collins, Kelsey H; Vallerand, Isabelle A; Wiley, J Preston; Woodhouse, Linda J; Reimer, Raylene A; Worobets, Jay T; Herzog, Walter; Stefanyshyn, Darren J

    2014-12-03

    Knee osteoarthritis (OA) progression has been linked to increased peak external knee adduction moments (KAMs). Although some trials have attempted to reduce pain and improve function in OA by reducing KAMs with a wedged footwear insole intervention, KAM reduction has not been specifically controlled for in trial designs, potentially explaining the mixed results seen in the literature. Therefore, the primary purpose of this trial is to identify the effects of reduced KAMs on knee OA pain and function. Forty-six patients with radiographically confirmed diagnosis medial knee OA will be recruited for this 3 month randomized controlled trial. Recruitment will be from Alberta and surrounding areas. Eligibility criteria include being between the ages of 40 and 85 years, have knee OA primarily localized to the medial tibiofemoral compartment, based on the American College of Rheumatology diagnostic criteria and be classified as having a Kellgren-Lawrence grade of 1 to 3. Patients will visit the laboratory at baseline for testing that includes dual x-ray absorptiometry, biomechanical testing, and surveys (KOOS, PASE activity scale, UCLA activity scale, comfort visual analog scale). At baseline, patients will be randomized to either a wedged insole group to reduce KAMs, or a waitlist control group where no intervention is provided. The survey tests will be repeated at 3 months, and response to wedged insoles over 3 months will be evaluated. This study represents the first step in systematically evaluating the effects of reduced KAMs on knee OA management by using a patient-specific wedged insole prescription procedure rather than providing the same insole to all patients. The results of this trial will provide indications as to whether reduced KAMs are an effective strategy for knee OA management, and whether a personalized approach to footwear insole prescription is warranted. NCT02067208.

  14. Study of variability in a virtual wedges A.L.E. Primus, measured weekly, for two years; Estudio de la variabilidad de las cunas virtuales en un A. L. E. Primus, medidas semanalmente, dure dos anos

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez Segovia, J.; Ruiz Vazquez, M.; Carrera Magarino, F.

    2011-07-01

    We try to analyze the stability of virtual wedges in the daily control of an electron linear accelerator (ALE), measuring weekly each wedge angle and for the two photon energies available on the machine.

  15. A flat spectral Faraday filter for sodium lidar.

    Science.gov (United States)

    Yang, Yong; Cheng, Xuewu; Li, Faquan; Hu, Xiong; Lin, Xin; Gong, Shunsheng

    2011-04-01

    We report a flat spectral Faraday anomalous dispersion optical filter (FS-FADOF) for sodium lidar. The physical and technical considerations for obtaining a FS-FADOF with a 3.5 GHz flat spectral transmission function are presented. It was found that the effective transmission of this filter was much higher (>94%) and more uniform than that of the ultranarrowband FADOF, and therefore were less sensitive to laser-frequency drift. Thus, the FS-FADOF can improve lidar efficiency and precision.

  16. An ancient stone facing strengthening with metal wedges at Iasos (Caria

    Directory of Open Access Journals (Sweden)

    Paolo Vitti

    2017-12-01

    Full Text Available This paper discusses a masonry strengthening on the wall of the Great bath building at Iasos in Caria. The analysis is based on the observation of a peculiar use of iron elements, inserted in the joints of a wall of the caldarium. The survey and the study of the wall has demonstrated that the facing of the wall separated from its core, probably due to an earthquake. The damage is likely to have occurred because of the big and heavy stones of the facing which were not bonded to the core of the wall. The use of iron wedges might have been an ideal solution for strengthening the wall without dismantling it.

  17. Computer dosimetry for flattened and wedged fast-neutron beams

    International Nuclear Information System (INIS)

    Hogstrom, K.R.; Smith, A.R.; Almond, P.R.; Otte, V.A.; Smathers, J.B.

    1976-01-01

    Beam flattening by the use of polyethylene filters has been developed for the 50-MeV d→Be fast-neutron therapy beam at the Texas AandM Variable-Energy Cyclotron (TAMVEC) as a result of the need for a more uniform dose distribution at depth within the patient. A computer algorithm has been developed that allows the use of a modified decrement line method to calculate dose distributions; standard decrement line methods do not apply because of off-axis peaking. The dose distributions for measured flattened beams are transformed into distributions that are physically equivalent to an unflattened distribution. In the transformed space, standard decrement line theory yields a distribution for any field size which, by applying the inverse transformation, generates the flattened dose distribution, including the off-axis peaking. A semiempirical model has been constructed that allows the calculation of dose distributions for wedged beams from open-beam data

  18. Intraoperative Ultrasound for Peripheral Nerve Applications.

    Science.gov (United States)

    Willsey, Matthew; Wilson, Thomas J; Henning, Phillip Troy; Yang, Lynda J-S

    2017-10-01

    Offering real-time, high-resolution images via intraoperative ultrasound is advantageous for a variety of peripheral nerve applications. To highlight the advantages of ultrasound, its extraoperative uses are reviewed. The current intraoperative uses, including nerve localization, real-time evaluation of peripheral nerve tumors, and implantation of leads for peripheral nerve stimulation, are reviewed. Although intraoperative peripheral nerve localization has been performed previously using guide wires and surgical dyes, the authors' approach using ultrasound-guided instrument clamps helps guide surgical dissection to the target nerve, which could lead to more timely operations and shorter incisions. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. An Automated Processing Algorithm for Flat Areas Resulting from DEM Filling and Interpolation

    Directory of Open Access Journals (Sweden)

    Xingwei Liu

    2017-11-01

    Full Text Available Correction of digital elevation models (DEMs for flat areas is a critical process for hydrological analyses and modeling, such as the determination of flow directions and accumulations, and the delineation of drainage networks and sub-basins. In this study, a new algorithm is proposed for flat correction/removal. It uses the puddle delineation (PD program to identify depressions (including their centers and overflow/spilling thresholds, compute topographic characteristics, and further fill the depressions. Three different levels of elevation increments are used for flat correction. The first and second level of increments create flows toward the thresholds and centers of the filled depressions or flats, while the third level of small random increments is introduced to cope with multiple threshold conditions. A set of artificial surfaces and two real-world landscapes were selected to test the new algorithm. The results showed that the proposed method was not limited by the shapes, the number of thresholds, and the surrounding topographic conditions of flat areas. Compared with the traditional methods, the new algorithm simplified the flat correction procedure and reduced the final elevation increments by 5.71–33.33%. This can be used to effectively remove/correct topographic flats and create flat-free DEMs.

  20. [Effectiveness of penile ventral scrotum cohesion place wedge cutting and improved Brisson technique for congenital buried penis].

    Science.gov (United States)

    Zhang, Huafeng

    2013-09-01

    To investigate the effectiveness of the penile ventral scrotum cohesion place wedge cutting and improved Brisson technique for congenital buried penis. Between March 2010 and June 2012, 68 boys with congenital buried penis were treated by the penile ventral scrotum cohesion place wedge cutting and improved Brisson technique, with a median age of 4 years and 10 months (range, 3 months-13 years). Of 68 cases, 14 were classified as phimosis type, 14 as rope belt type, 20 as moderate type, and 20 as severe type. The body of penis developed well and had no deformity. After operation, complications were observed, and the effectiveness was evaluated by the designed questionnaire. Early postoperative complications occurred in 11 cases, including obvious adhesion of the outside wrapping mouth in 4 cases, scrotal skin bloat in 5 cases, and distal foreskin necrosis in 2 cases; long-term complications occurred in 9 cases, including abdominal incision scar formation in 4 cases, wrapping mouth scar stricture in 3 cases, and short penis in 2 cases. Primary healing of incision was obtained in the other boys. Fifty-four cases were followed up 6-12 months (mean, 8 months). According to the designed questionnaire, satisfaction rate with the overall view in parents was 77.78% (42/54); the clinical improvement rate was 85.19% (46/54); exposure of the penis was satisfactory in parents of 50 cases; and the parents had no psychological burden of penis exposure in 46 cases, which were significantly improved when compared with preoperative ones (P penis exposure in 29 cases (53.70%) after operation, showing no significant difference when compared with preoperative one (18 cases, 33.33%) (chi2 = 1.22, P = 0.31). Application of the penile ventral scrotum cohesion place wedge cutting and improved Brisson technique can effectively correct congenital buried penis.