WorldWideScience

Sample records for peripheral chemoreflex loop

  1. Peripheral chemoreflex inhibition with low-dose dopamine: new insight into mechanisms of extreme apnea.

    Science.gov (United States)

    Bain, Anthony R; Dujic, Zeljko; Hoiland, Ryan L; Barak, Otto F; Madden, Dennis; Drvis, Ivan; Stembridge, Mike; MacLeod, David B; MacLeod, Douglas M; Ainslie, Philip N

    2015-11-01

    The purpose of this study was to determine the impact of peripheral chemoreflex inhibition with low-dose dopamine on maximal apnea time, and the related hemodynamic and cerebrovascular responses in elite apnea divers. In a randomized order, participants performed a maximal apnea while receiving either intravenous 2 μg·kg(-1)·min(-1) dopamine or volume-matched saline (placebo). The chemoreflex and hemodynamic response to dopamine was also assessed during hypoxia [arterial O2 tension, (PaO2 ) ∼35 mmHg] and mild hypercapnia [arterial CO2 tension (PaCO2 ) ∼46 mmHg] that mimicked the latter parts of apnea. Outcome measures included apnea duration, arterial blood gases (radial), heart rate (HR, ECG), mean arterial pressure (MAP, intra-arterial), middle (MCAv) and posterior (PCAv) cerebral artery blood velocity (transcranial ultrasound), internal carotid (ICA) and vertebral (VA) artery blood flow (ultrasound), and the chemoreflex responses. Although dopamine depressed the ventilatory response by 27 ± 41% (vs. placebo; P = 0.01), the maximal apnea duration was increased by only 5 ± 8% (P = 0.02). The PaCO2 and PaO2 at apnea breakpoint were similar (P > 0.05). When compared with placebo, dopamine increased HR and decreased MAP during both apnea and chemoreflex test (P all breathe. Copyright © 2015 the American Physiological Society.

  2. The effects of carbon monoxide on respiratory chemoreflexes in humans

    International Nuclear Information System (INIS)

    Vesely, A.E.; Somogyi, R.B.; Sasano, Hiroshi; Sasano, Nobuko; Fisher, J.A.; Duffin, James

    2004-01-01

    As protection against low-oxygen and high-carbon-dioxide environments, the respiratory chemoreceptors reflexly increase breathing. Since CO is also frequently present in such environments, it is important to know whether CO affects the respiratory chemoreflexes responsiveness. Although the peripheral chemoreceptors fail to detect hypoxia produced by CO poisoning, whether CO affects the respiratory chemoreflex responsiveness to carbon dioxide is unknown. The responsiveness of 10 healthy male volunteers were assessed before and after inhalation of ∼1200 ppm CO in air using two iso-oxic rebreathing tests; hypoxic, to emphasize the peripheral chemoreflex, and hyperoxic, to emphasize the central chemoreflex. Although mean (SEM) COHb values of 10.2 (0.2)% were achieved, no statistically significant effects of CO were observed. The average differences between pre- and post-CO values for ventilation response threshold and sensitivity were -0.5 (0.9) mmHg and 0.8 (0.3) L/min/mmHg, respectively, for hyperoxia, and 0.7 (1.1) mmHg and 1.2 (0.8) L/min/mmHg, respectively, for hypoxia. The 95% confidence intervals for the effect of CO were small. We conclude that environments with low levels of CO do not have a clinically significant effect acutely on either the central or the peripheral chemoreflex responsiveness to carbon dioxide

  3. Comparing and characterizing transient and steady-state tests of the peripheral chemoreflex in humans.

    Science.gov (United States)

    Pfoh, Jamie R; Tymko, Michael M; Abrosimova, Maria; Boulet, Lindsey M; Foster, Glen E; Bain, Anthony R; Ainslie, Philip N; Steinback, Craig D; Bruce, Christina D; Day, Trevor A

    2016-03-01

    What is the central question of this study? We aimed to characterize the cardiorespiratory and cerebrovascular responses to transient and steady-state tests of the peripheral chemoreflex and to compare the hypoxic ventilatory responses (HVRs) between these tests. What is the main finding and its importance? The cardiovascular and cerebrovascular responses to transient tests were small in magnitude and short in duration. The steady-state isocapnic hypoxia test elicited a larger HVR than the transient 100% N(2) test, but the response magnitudes were correlated within individuals. The transient test of the HVR elicits fewer systemic effects than steady-state techniques and may have greater experimental utility than previously appreciated. Carotid chemoreceptors detect changes in arterial PO(2) and PCO(2), eliciting a peripheral chemoreflex (PCR). Steady-state (SS) hypoxia tests using dynamic end-tidal forcing (DEF) have been used to assess the hypoxic ventilatory response (HVR) but may be confounded by concomitant systemic effects. Transient tests of the PCR have also been developed but are not widely used, nor have the cardiovascular and cerebrovascular responses been characterized. We characterized the cardiorespiratory and cerebrovascular responses to transient tests of the PCR and compared the HVR between transient and SS-DEF tests. We hypothesized that the cardiovascular and cerebrovascular responses to the transient tests would be minimal and that the respiratory responses elicited from the transient and SS-DEF tests would be different in magnitude and not well correlated within individuals. Participants underwent five consecutive trials of two transient tests [three-breath 100% N(2) (TT-N(2)) and a single-breath 13% CO(2), in air] and two 10 min SS-DEF tests [isocapnic (SS-ISO) and poikilocapnic (SS-POI) hypoxia]. In response to the transient tests, heart rate, mean arterial pressure and the middle and posterior cerebral artery blood velocity increased (all P

  4. CAROTID BODY CHEMO-REFLEX: A DRIVER OF AUTONOMIC ABNORMALITIES IN SLEEP APNEA

    Science.gov (United States)

    Prabhakar, Nanduri R.

    2016-01-01

    Carotid bodies are the principal peripheral chemoreceptors for detecting changes in arterial blood oxygen levels, and the resulting chemo-reflex is a potent regulator of the sympathetic tone, blood pressure, and breathing. Sleep apnea is a disease of the respiratory system affecting several million adult humans. Apneas occur during sleep often due to obstruction of the upper airway (obstructive sleep apnea, OSA) or due to defective respiratory rhythm generation by the central nervous system (central sleep apnea). Patients with sleep apnea exhibit several co-morbidities; most notable among them being the heightened sympathetic nerve activity, and hypertension. Emerging evidence suggests that intermittent hypoxia (IH) resulting from periodic apnea stimulates the carotid body and the ensuing chemo-reflex mediates the increased sympathetic tone and hypertension in sleep apnea patients. Rodent models of IH, simulating the O2 saturation profiles encountered during sleep apnea have provided important insights into the cellular and molecular mechanisms underlying the heightened carotid body chemo-reflex. This article describes how IH affects the carotid body function, and discusses the cellular, molecular and epigenetic mechanisms underlying the exaggerated chemo-reflex. PMID:27474260

  5. Prediction of the Chemoreflex Gain by Common Clinical Variables in Heart Failure.

    Directory of Open Access Journals (Sweden)

    Gianluca Mirizzi

    Full Text Available Peripheral and central chemoreflex sensitivity, assessed by the hypoxic or hypercapnic ventilatory response (HVR and HCVR, respectively, is enhanced in heart failure (HF patients, is involved in the pathophysiology of the disease, and is under investigation as a potential therapeutic target. Chemoreflex sensitivity assessment is however demanding and, therefore, not easily applicable in the clinical setting. We aimed at evaluating whether common clinical variables, broadly obtained by routine clinical and instrumental evaluation, could predict increased HVR and HCVR.191 patients with systolic HF (left ventricular ejection fraction--LVEF--<50% underwent chemoreflex assessment by rebreathing technique to assess HVR and HCVR. All patients underwent clinical and neurohormonal evaluation, comprising: echocardiogram, cardiopulmonary exercise test (CPET, daytime cardiorespiratory monitoring for breathing pattern evaluation. Regarding HVR, multivariate penalized logistic regression, Bayesian Model Averaging (BMA logistic regression and random forest analysis identified, as predictors, the presence of periodic breathing and increased slope of the relation between ventilation and carbon dioxide production (VE/VCO2 during exercise. Again, the above-mentioned statistical tools identified as HCVR predictors plasma levels of N-terminal fragment of proBNP and VE/VCO2 slope.In HF patients, the simple assessment of breathing pattern, alongside with ventilatory efficiency during exercise and natriuretic peptides levels identifies a subset of patients presenting with increased chemoreflex sensitivity to either hypoxia or hypercapnia.

  6. Intra-individual variability in cerebrovascular and respiratory chemosensitivity: Can we characterize a chemoreflex "reactivity profile"?

    Science.gov (United States)

    Borle, Kennedy J; Pfoh, Jamie R; Boulet, Lindsey M; Abrosimova, Maria; Tymko, Michael M; Skow, Rachel J; Varner, Amy; Day, Trevor A

    2017-08-01

    Intra-individual variability in the magnitude of human cerebrovascular and respiratory chemoreflex responses is largely unexplored. By comparing response magnitudes of cerebrovascular CO 2 reactivity (CVR; middle and posterior cerebral arteries; MCA, PCA), central (CCR; CO 2 ) and peripheral respiratory chemoreflexes (PCR; CO 2 and O 2 ), we tested the hypothesis that a within-individual reactivity magnitude profile could be characterized. The magnitudes of CVR and CCR were tested with hyperoxic rebreathing and PCR magnitudes were tested through transient respiratory tests (TT-CO 2 , hypercapnia; TT-N 2 , hypoxia). No significant intra-individual relationships were found between CCR vs. CVR (MCA and PCA), CCR vs. PCR (TT-N 2 or TT-CO 2 ) (r0.3) response magnitudes. Statistically significant relationships were found between MCA vs. PCA reactivity (r=0.45, Pvariability that exists in human cerebrovascular and respiratory chemoreflexes. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Peripheral Chemoreception and Arterial Pressure Responses to Intermittent Hypoxia

    Science.gov (United States)

    Prabhakar, Nanduri R.; Peng, Ying-Jie; Kumar, Ganesh K.; Nanduri, Jayasri

    2015-01-01

    Carotid bodies are the principal peripheral chemoreceptors for detecting changes in arterial blood oxygen levels, and the resulting chemoreflex is a potent regulator of blood pressure. Recurrent apnea with intermittent hypoxia (IH) is a major clinical problem in adult humans and infants born preterm. Adult patients with recurrent apnea exhibit heightened sympathetic nerve activity and hypertension. Adults born preterm are predisposed to early onset of hypertension. Available evidence suggests that carotid body chemoreflex contributes to hypertension caused by IH in both adults and neonates. Experimental models of IH provided important insights into cellular and molecular mechanisms underlying carotid body chemoreflex-mediated hypertension. This article provides a comprehensive appraisal of how IH affects carotid body function, underlying cellular, molecular, and epigenetic mechanisms, and the contribution of chemoreflex to the hypertension. PMID:25880505

  8. Peripheral chemoreception and arterial pressure responses to intermittent hypoxia.

    Science.gov (United States)

    Prabhakar, Nanduri R; Peng, Ying-Jie; Kumar, Ganesh K; Nanduri, Jayasri

    2015-04-01

    Carotid bodies are the principal peripheral chemoreceptors for detecting changes in arterial blood oxygen levels, and the resulting chemoreflex is a potent regulator of blood pressure. Recurrent apnea with intermittent hypoxia (IH) is a major clinical problem in adult humans and infants born preterm. Adult patients with recurrent apnea exhibit heightened sympathetic nerve activity and hypertension. Adults born preterm are predisposed to early onset of hypertension. Available evidence suggests that carotid body chemoreflex contributes to hypertension caused by IH in both adults and neonates. Experimental models of IH provided important insights into cellular and molecular mechanisms underlying carotid body chemoreflex-mediated hypertension. This article provides a comprehensive appraisal of how IH affects carotid body function, underlying cellular, molecular, and epigenetic mechanisms, and the contribution of chemoreflex to the hypertension. © 2015 American Physiological Society.

  9. Influence of chemoreflexes on respiratory variability in healthy subjects

    NARCIS (Netherlands)

    van den Aardweg, Joost G.; Karemaker, John M.

    2002-01-01

    The background of this study was the hypothesis that respiratory variability is influenced by chemoreflex regulation, In search for periodicities in the variability due to instability of the respiratory control system, spectral analysis was applied to breath-to-breath variables in 19 healthy

  10. Well-observed dynamics of flaring and peripheral coronal magnetic loops during an M-class limb flare

    International Nuclear Information System (INIS)

    Shen, Jinhua; Zhou, Tuanhui; Ji, Haisheng; Feng, Li; Wiegelmann, Thomas; Inhester, Bernd

    2014-01-01

    In this paper, we present a variety of well-observed dynamic behaviors for the flaring and peripheral magnetic loops of the M6.6 class extreme limb flare that occurred on 2011 February 24 (SOL2011-02-24T07:20) from EUV observations by the Atmospheric Imaging Assembly on the Solar Dynamics Observatory and X-ray observations by RHESSI. The flaring loop motion confirms the earlier contraction-expansion picture. We find that the U-shaped trajectory delineated by the X-ray corona source of the flare roughly follows the direction of a filament eruption associated with the flare. Different temperature structures of the coronal source during the contraction and expansion phases strongly suggest different kinds of magnetic reconnection processes. For some peripheral loops, we discover that their dynamics are closely correlated with the filament eruption. During the slow rising to abrupt, fast rising of the filament, overlying peripheral magnetic loops display different responses. Two magnetic loops on the elbow of the active region had a slow descending motion followed by an abrupt successive fast contraction, while magnetic loops on the top of the filament were pushed outward, slowly being inflated for a while and then erupting as a moving front. We show that the filament activation and eruption play a dominant role in determining the dynamics of the overlying peripheral coronal magnetic loops.

  11. Peripheral Chemoreception and Arterial Pressure Responses to Intermittent Hypoxia

    OpenAIRE

    Prabhakar, Nanduri R.; Peng, Ying-Jie; Kumar, Ganesh K.; Nanduri, Jayasri

    2015-01-01

    Carotid bodies are the principal peripheral chemoreceptors for detecting changes in arterial blood oxygen levels, and the resulting chemoreflex is a potent regulator of blood pressure. Recurrent apnea with intermittent hypoxia (IH) is a major clinical problem in adult humans and infants born preterm. Adult patients with recurrent apnea exhibit heightened sympathetic nerve activity and hypertension. Adults born preterm are predisposed to early onset of hypertension. Available evidence suggests...

  12. Hyperadditive Ventilatory Response Arising from Interaction between the Carotid Chemoreflex and the Muscle Mechanoreflex in Healthy Humans.

    Science.gov (United States)

    Silva, Talita M; Aranda, Liliane C; Paula-Ribeiro, Marcelle; Oliveira, Diogo M; Medeiros, Wladimir Musetti; Vianna, Lauro C; Nery, Luiz E; Silva, Bruno M

    2018-03-22

    Physical exercise potentiates the carotid chemoreflex control of ventilation (VE). Hyperadditive neural interactions may partially mediate the potentiation. However, some neural interactions remain incompletely explored. As the potentiation occurs even during low-intensity exercise, we tested the hypothesis that the carotid chemoreflex and the muscle mechanoreflex could interact in a hyperadditive fashion. Fourteen young healthy subjects inhaled, randomly, in separate visits, 12% O 2 to stimulate the carotid chemoreflex, and 21% O 2 as control. A rebreathing circuit maintained isocapnia. During gases administration, subjects either remained at rest (i.e., normoxic and hypoxic rest) or the muscle mechanoreflex was stimulated, via passive knee movement (i.e., normoxic and hypoxic movement). Surface muscle electrical activity did not increase during the passive movement, confirming the absence of active contractions. Hypoxic rest and normoxic movement similarly increased VE [change (mean {plus minus} SEM) = 1.24 {plus minus} 0.72 vs. 0.73 {plus minus} 0.43 L/min, respectively; P = 0.46], but hypoxic rest only increased tidal volume (Vt) and normoxic movement only increased breathing frequency (BF). Hypoxic movement induced greater VE and mean inspiratory flow (Vt/Ti) increase than the sum of hypoxic rest and normoxic movement isolated responses (VE change: hypoxic movement = 3.72 {plus minus} 0.81 vs. sum = 1.96 {plus minus} 0.83 L/min, P = 0.01; Vt/Ti change: hypoxic movement = 0.13 {plus minus} 0.03 vs. sum = 0.06 {plus minus} 0.03 L/s, P = 0.02). Moreover, hypoxic movement increased both Vt and BF. Collectively, the results indicate the carotid chemoreflex and the muscle mechanoreflex interacted mediating a hyperadditive ventilatory response in healthy humans.

  13. Acrolein Causes TRPA1-Mediated Sensory Irritation and Indirect Potentiation of TRPV1-Mediated Pulmonary Chemoreflex Response

    Science.gov (United States)

    We previously demonstrated that acute exposure to acrolein causes immediate sensory irritation, with rapid decrease in heart rate (HR) and increase in inspiratory time (Ti), and potentiation of pulmonary chemoreflex response 24hrs later; of these effects only the latter is mediat...

  14. [The prediction of atrial fibrillation recurrence after electrical cardioversion with the chemoreflex sensitivity].

    Science.gov (United States)

    Budeus, M; Hennersdorf, M; Perings, C; Strauer, B E

    2004-04-01

    Patients with paroxysmal atrial fibrillation have a lower chemoreflex sensitivity (CHRS) which is characterized as an autonomic dysfunction. Because of this observation we examined the theory of an autonomic dysfunction as the reason for the reccurrence of atrial fibrilation after electrical cardioversion. We measured the CHRS among 43 patients 24 h after successful electrical cardioversion and the patients were controlled for at least 6 months. During the six months of follow-up a recurrence was observed in 18 patients with a mean of 8.3 days. There was no difference in organic heart disease or in the use of drugs. Left atrial diameter was not significantly larger in patients with a recurrence. Patients with a recurrence have a significantly lower CHRS than patients with sinus rhythm (2.41 +/- 1.82 vs 5.62 +/- 3.02 ms/mmHg, p atrial fibrillation. The predictive power of the method has to be examined by prospective investigations of a larger patient population and a longer follow-up. Patients with paroxysmal atrial fibrillation have a lower chemoreflex sensitivity (CHRS) which is characterized as an autonomic dysfunction. Because of this observation we examined the theory of an autonomic dysfunction as the reason for the recurrence of atrial fibrillation after electrical cardioversion.

  15. Forced vital capacity and not central chemoreflex predicts maximal hyperoxic breath-hold duration in elite apneists.

    Science.gov (United States)

    Bain, Anthony R; Barak, Otto F; Hoiland, Ryan L; Drvis, Ivan; Bailey, Damian M; Dujic, Zeljko; Mijacika, Tanja; Santoro, Antoinette; DeMasi, Daniel K; MacLeod, David B; Ainslie, Philip N

    2017-08-01

    The determining mechanisms of a maximal hyperoxic apnea duration in elite apneists have remained unexplored. We tested the hypothesis that maximal hyperoxic apnea duration in elite apneists is related to forced vital capacity (FVC) but not the central chemoreflex (for CO 2 ). Eleven elite apneists performed a maximal dry static-apnea with prior hyperoxic (100% oxygen) pre-breathing, and a central chemoreflex test via a hyperoxic re-breathing technique (hyperoxic-hypercapnic ventilatory response: HCVR); expressed as the increase in ventilation (pneumotachometry) per increase in arterial CO 2 tension (PaCO 2 ; radial artery). FVC was assessed using standard spirometry. Maximal apnea duration ranged from 807 to 1262s (mean=1034s). Average HCVR was 2.0±1.2Lmin -1 mmHg -1 PaCO 2 . The hyperoxic apnea duration was related to the FVC (r 2 =0.45, p0.05). These findings were interpreted to suggest that during a hyperoxic apnea, a larger initial lung volume prolongs the time before reaching intolerable discomfort associated with pending lung squeeze, while CO 2 sensitivity has little impact. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Comportamento dos quimiorreflexos central e periférico na insuficiência cardíaca Comportamiento de los quimiorreflejos central y periférico en la insuficiencia cardíaca Behavior of central and peripheral chemoreflexes in heart failure

    Directory of Open Access Journals (Sweden)

    Guilherme Veiga Guimarães

    2011-02-01

    practice of exercises. There is evidence that the autonomic imbalance contributes to the pathogenesis and the progression of heart failure. The chemoreflexes are the main mechanisms of control and regulation of the ventilatory responses to the changes in concentrations of arterial oxygen and carbon dioxide. The chemoreflex activation causes an increase in the sympathetic activity, heart rate, arterial pressure and minute volume. However, the increase in the minute volume and the arterial pressure, due to negative feedback, cause inhibition of the sympathetic response at the chemoreflex activation. In spite of the functional alterations of the reflexes, their behavior in normal and pathological conditions, especially their contribution to the sympathoexcitatory state observed in HF has not been broadly studied. Therefore, this review aims at integrating the knowledge on central and peripheral chemoreflexes in HF syndrome, as well as clarifying the influence of the heart failure drug therapy on the chemoreflexes.

  17. Towards a closed-loop cochlear implant system: application of embedded monitoring of peripheral and central neural activity.

    Science.gov (United States)

    Mc Laughlin, Myles; Lu, Thomas; Dimitrijevic, Andrew; Zeng, Fan-Gang

    2012-07-01

    Although the cochlear implant (CI) is widely considered the most successful neural prosthesis, it is essentially an open-loop system that requires extensive initial fitting and frequent tuning to maintain a high, but not necessarily optimal, level of performance. Two developments in neuroscience and neuroengineering now make it feasible to design a closed-loop CI. One development is the recording and interpretation of evoked potentials (EPs) from the peripheral to the central nervous system. The other is the embedded hardware and software of a modern CI that allows recording of EPs. We review EPs that are pertinent to behavioral functions from simple signal detection and loudness growth to speech discrimination and recognition. We also describe signal processing algorithms used for electric artifact reduction and cancellation, critical to the recording of electric EPs. We then present a conceptual design for a closed-loop CI that utilizes in an innovative way the embedded implant receiver and stimulators to record short latency compound action potentials ( ~1 ms), auditory brainstem responses (1-10 ms) and mid-to-late cortical potentials (20-300 ms). We compare EPs recorded using the CI to EPs obtained using standard scalp electrodes recording techniques. Future applications and capabilities are discussed in terms of the development of a new generation of closed-loop CIs and other neural prostheses.

  18. Chronic hypoxic incubation blunts a cardiovascular reflex loop in embryonic American alligator (Alligator mississippiensis).

    Science.gov (United States)

    Eme, John; Hicks, James W; Crossley, Dane A

    2011-10-01

    Hypoxia is a naturally occurring environmental challenge for embryonic non-avian reptiles, and this study is the first to investigate the impact of chronic hypoxia on a possible chemoreflex loop in a developing non-avian reptile. We measured heart rate and blood pressure in normoxic and hypoxic-incubated (10% O(2)) American alligator embryos (Alligator mississippiensis) at 70 and 90/95% of development. We hypothesized that hypoxic incubation would blunt embryonic alligators' response to a reflex loop stimulated by phenylbiguanide (PBG), a 5-HT(3) receptor agonist that stimulates vagal pulmonary C-fiber afferents. PBG injection caused a hypotensive bradycardia in 70 and 95% of development embryos (paired t tests, P alligator, with an extended length of time between each developmental stage relative to avian species, may provide an excellent model to test the cardiorespiratory effects of prolonged exposure to changes in atmospheric gases. This extended period allows for lengthy studies at each stage without the transition to a new stage, and the natural occurrence of hypoxia and hypercapnia in crocodilian nests makes this stress ecologically and evolutionarily relevant.

  19. Model-based characterization of ventilatory stability using spontaneous breathing

    OpenAIRE

    Nemati, Shamim; Edwards, Bradley A.; Sands, Scott A.; Berger, Philip J.; Wellman, Andrew; Verghese, George C.; Malhotra, Atul; Butler, James P.

    2011-01-01

    Cyclic ventilatory instabilities are widely attributed to an increase in the sensitivity or loop gain of the chemoreflex feedback loop controlling ventilation. A major limitation in the conventional characterization of this feedback loop is the need for labor-intensive methodologies. To overcome this limitation, we developed a method based on trivariate autoregressive modeling using ventilation, end-tidal Pco2 and Po2; this method provides for estimation of the overall “loop gain” of the resp...

  20. Clinical predictors and hemodynamic consequences of elevated peripheral chemosensitivity in optimally treated men with chronic systolic heart failure.

    Science.gov (United States)

    Niewinski, Piotr; Engelman, Zoar J; Fudim, Marat; Tubek, Stanislaw; Paleczny, Bartlomiej; Jankowska, Ewa A; Banasiak, Waldemar; Sobotka, Paul A; Ponikowski, Piotr

    2013-06-01

    Augmented peripheral chemoreflex response is an important mechanism in the pathophysiology of chronic heart failure (CHF). This study characterizes prevalence and clinical predictors of this phenomenon in optimally managed male CHF patients, and seeks to describe the hemodynamic consequences of chemoreceptor hypersensitivity. Thirty-four optimally managed CHF patients and 16 control subjects were prospectively studied. Hypoxic ventilatory response (HVR)-a measure of peripheral chemosensitivity-was calculated with the use of short nitrogen gas administrations. Systolic blood pressure (SBP) and heart rate (HR) following transient hypoxic challenges were recorded with a Nexfin monitor. Hemodynamic responses to hypoxia were expressed by the linear slopes between oxygen saturation (%) and SBP (mm Hg) or HR (beats/min). Elevated HVR was present in 15 (44%) of the CHF patients. Patients with elevated HVR exhibited higher levels of N-terminal pro-B-type natriuretic peptide, lower left ventricular ejection fraction, and higher prevalence of atrial fibrillation. CHF patients with elevated HVR had significantly greater SBP and HR responses to hypoxia than CHF patients with normal HVR. Despite comprehensive pharmacotherapy, elevated HVR is prevalent in CHF patients, related to severity of the disease and associated with augmented hemodynamic responses to hypoxia. CHF patients with elevated HVR may be prone to unfavorable hemodynamic changes. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. First cytoplasmic loop of glucagon-like peptide-1 receptor can function at the third cytoplasmic loop position of rhodopsin.

    Science.gov (United States)

    Yamashita, Takahiro; Tose, Koji; Shichida, Yoshinori

    2008-01-01

    G protein-coupled receptors (GPCRs) are classified into several families based on their amino acid sequences. In family 1, GPCRs such as rhodopsin and adrenergic receptor, the structure-function relationship has been extensively investigated to demonstrate that exposure of the third cytoplasmic loop is essential for selective G protein activation. In contrast, much less is known about other families. Here we prepared chimeric mutants between Gt-coupled rhodopsin and Gi/Go- and Gs-coupled glucagon-like peptide-1 (GLP-1) receptor of family 2 and tried to identify the loop region that functions at the third cytoplasmic loop position of rhodopsin. We succeeded in expressing a mutant having the first cytoplasmic loop of GLP-1 receptor and found that this mutant activated Gi and Go efficiently but did not activate Gt. Moreover, the rhodopsin mutant having the first loop of Gs-coupled secretin receptor of family 2 decreased the Gi and Go activation efficiencies. Therefore, the first loop of GLP-1 receptor would share a similar role to the third loop of rhodopsin in G protein activation. This result strongly suggested that different families of GPCRs have maintained molecular architectures of their ancestral types to generate a common mechanism, namely exposure of the cytoplasmic loop, to activate peripheral G protein.

  2. Update on Peripheral Nerve Electrodes for Closed-Loop Neuroprosthetics

    Directory of Open Access Journals (Sweden)

    Emil H. Rijnbeek

    2018-05-01

    Full Text Available In this paper various types of electrodes for stimulation and recording activity of peripheral nerves for the control of neuroprosthetic limbs are reviewed. First, an overview of interface devices for (feedback- controlled movement of a prosthetic device is given, after which the focus is on peripheral nervous system (PNS electrodes. Important electrode properties, i.e., longevity and spatial resolution, are defined based upon the usability for neuroprostheses. The cuff electrode, longitudinal intrafascicular electrodes (LIFE, transverse intrafascicular multichannel electrode (TIME, Utah slanted electrode array (USEA, and the regenerative electrode are discussed and assessed on their longevity and spatial resolution. The cuff electrode seems to be a promising electrode for the control of neuroprostheses in the near future, because it shows the best longevity and good spatial resolution and it has been used on human subjects in multiple studies. The other electrodes may be promising in the future, but further research on their longevity and spatial resolution is needed. A more quantitatively uniform study protocol used for all electrodes would allow for a proper comparison of recording and stimulation performance. For example, the discussed electrodes could be compared in a large in vivo study, using one uniform comparison protocol.

  3. Peripheral myelin protein 22 alters membrane architecture

    Science.gov (United States)

    Mittendorf, Kathleen F.; Marinko, Justin T.; Hampton, Cheri M.; Ke, Zunlong; Hadziselimovic, Arina; Schlebach, Jonathan P.; Law, Cheryl L.; Li, Jun; Wright, Elizabeth R.; Sanders, Charles R.; Ohi, Melanie D.

    2017-01-01

    Peripheral myelin protein 22 (PMP22) is highly expressed in myelinating Schwann cells of the peripheral nervous system. PMP22 genetic alterations cause the most common forms of Charcot-Marie-Tooth disease (CMTD), which is characterized by severe dysmyelination in the peripheral nerves. However, the functions of PMP22 in Schwann cell membranes remain unclear. We demonstrate that reconstitution of purified PMP22 into lipid vesicles results in the formation of compressed and cylindrically wrapped protein-lipid vesicles that share common organizational traits with compact myelin of peripheral nerves in vivo. The formation of these myelin-like assemblies depends on the lipid-to-PMP22 ratio, as well as on the PMP22 extracellular loops. Formation of the myelin-like assemblies is disrupted by a CMTD-causing mutation. This study provides both a biochemical assay for PMP22 function and evidence that PMP22 directly contributes to membrane organization in compact myelin. PMID:28695207

  4. High-temperature helium-loop facility

    International Nuclear Information System (INIS)

    Tokarz, R.D.

    1981-09-01

    The high-temperature helium loop is a facility for materials testing in ultrapure helium gas at high temperatures. The closed loop system is capable of recirculating high-purity helium or helium with controlled impurities. The gas loop maximum operating conditions are as follows: 300 psi pressure, 500 lb/h flow rate, and 2100 0 F temperature. The two test sections can accept samples up to 3.5 in. diameter and 5 ft long. The gas loop is fully instrumented to continuously monitor all parameters of loop operation as well as helium impurities. The loop is fully automated to operate continuously and requires only a daily servicing by a qualified operator to replenish recorder charts and helium makeup gas. Because of its versatility and high degree of parameter control, the helium loop is applicable to many types of materials research. This report describes the test apparatus, operating parameters, peripheral systems, and instrumentation system. The experimental capabilities and test conand presents the results that have been obtained. The study has been conducted using a four-phase approach. The first phase develops the solution to the steady-state radon-diffusion equation in one-dimensieered barriers; disposal charge analysis; analysis of spent fuel policy implementation; spent f water. Field measurements and observations are reported for each site. Analytical data and field measurements are presented in tables and maps. Uranium concentrations in the sediments which were above detection limits ranged from 0.10 t 51.2 ppM. The mean of the logarithms of the uranium concentrations was 0.53. A group of high uranium concentrations occurs near the junctions of quadrangles AB, AC, BB, a 200 mK. In case 2), x-ray studies of isotopic phase separation in 3 He-- 4 He bcc solids were carried out by B. A. Fraass

  5. Perinatal Fluoxetine Exposure Impairs the CO2 Chemoreflex. Implications for Sudden Infant Death Syndrome.

    Science.gov (United States)

    Bravo, Karina; Eugenín, Jaime L; Llona, Isabel

    2016-09-01

    High serotonin levels during pregnancy affect central nervous system development. Whether a commonly used antidepressant such as fluoxetine (a selective serotonin reuptake inhibitor) taken during pregnancy may adversely affect respiratory control in offspring has not been determined. The objective was to determine the effect of prenatal-perinatal fluoxetine exposure on the respiratory neural network in offspring, particularly on central chemoreception. Osmotic minipumps implanted into CF-1 mice on Days 5-7 of pregnancy delivered 7 milligrams per kilogram per day of fluoxetine, achieving plasma levels within the range found in patients. Ventilation was assessed in offspring at postnatal Days 0-40 using head-out body plethysmography. Neuronal activation was evaluated in the raphe nuclei and in the nucleus tractus solitarius by c-Fos immunohistochemistry during normoxic eucapnia and hypercapnia (10% CO2). Respiratory responses to acidosis were evaluated in brainstem slices. Prenatal-perinatal fluoxetine did not affect litter size, birth weight, or the postnatal growth curve. Ventilation under eucapnic normoxic conditions was similar to that of control offspring. Fluoxetine exposure reduced ventilatory responses to hypercapnia at P8-P40 (P Fluoxetine applied acutely on control slices did not modify their respiratory response to acidosis. We concluded that prenatal-perinatal fluoxetine treatment impairs central respiratory chemoreception during postnatal life. These results are relevant in understanding the pathogenesis of respiratory failures, such as sudden infant death syndrome, associated with brainstem serotonin abnormalities and the failure of respiratory chemoreflexes.

  6. Exercise training attenuates chemoreflex-mediated reductions of renal blood flow in heart failure.

    Science.gov (United States)

    Marcus, Noah J; Pügge, Carolin; Mediratta, Jai; Schiller, Alicia M; Del Rio, Rodrigo; Zucker, Irving H; Schultz, Harold D

    2015-07-15

    In chronic heart failure (CHF), carotid body chemoreceptor (CBC) activity is increased and contributes to increased tonic and hypoxia-evoked elevation in renal sympathetic nerve activity (RSNA). Elevated RSNA and reduced renal perfusion may contribute to development of the cardio-renal syndrome in CHF. Exercise training (EXT) has been shown to abrogate CBC-mediated increases in RSNA in experimental heart failure; however, the effect of EXT on CBC control of renal blood flow (RBF) is undetermined. We hypothesized that CBCs contribute to tonic reductions in RBF in CHF, that stimulation of the CBC with hypoxia would result in exaggerated reductions in RBF, and that these responses would be attenuated with EXT. RBF was measured in CHF-sedentary (SED), CHF-EXT, CHF-carotid body denervation (CBD), and CHF-renal denervation (RDNX) groups. We measured RBF at rest and in response to hypoxia (FiO2 10%). All animals exhibited similar reductions in ejection fraction and fractional shortening as well as increases in ventricular systolic and diastolic volumes. Resting RBF was lower in CHF-SED (29 ± 2 ml/min) than in CHF-EXT animals (46 ± 2 ml/min, P < 0.05) or in CHF-CBD animals (42 ± 6 ml/min, P < 0.05). In CHF-SED, RBF decreased during hypoxia, and this was prevented in CHF-EXT animals. Both CBD and RDNX abolished the RBF response to hypoxia in CHF. Mean arterial pressure increased in response to hypoxia in CHF-SED, but was prevented by EXT, CBD, and RDNX. EXT is effective in attenuating chemoreflex-mediated tonic and hypoxia-evoked reductions in RBF in CHF. Copyright © 2015 the American Physiological Society.

  7. ECP measurements under neutron and gamma ray in in-pile loop and their data evaluation by water radiolysis calculations

    Energy Technology Data Exchange (ETDEWEB)

    Hanawa, S.; Nakamura, T.; Uchida, S. [Japan Atomic Energy Agency, Tokai-mura, Ibaraki (Japan); Kus, P.; Vsolak, R.; Kysela, J. [Nuclear Research Inst. Rez plc, Husinec - Rez (Czech Republic)

    2010-07-01

    In order to establish reliable electrochemical corrosion potential (ECP) sensors for applying in reactor core peripherals of power plants, performance tests of sensors under irradiation were carried out in the in-pile loop of the experimental reactor, LVR-15, at the Nuclear Research Institute (NRI) in Czech Republic. Responses of different kinds of sensors under neutron and gamma irradiation conditions have been compared each other. Corrosive conditions along the in-pile loop were calculated by water radiolysis calculation code, WRAC-J and calculated corrosive conditions were compared with the measured results. As a result of the evaluation, it was confirmed that the ECP sensors could be applied to irradiation conditions of reactor peripherals, while the water radiolysis model could be also applied for evaluation of corrosive conditions of reactor peripherals. (author)

  8. NPAS2 Compensates for Loss of CLOCK in Peripheral Circadian Oscillators.

    Directory of Open Access Journals (Sweden)

    Dominic Landgraf

    2016-02-01

    Full Text Available Heterodimers of CLOCK and BMAL1 are the major transcriptional activators of the mammalian circadian clock. Because the paralog NPAS2 can substitute for CLOCK in the suprachiasmatic nucleus (SCN, the master circadian pacemaker, CLOCK-deficient mice maintain circadian rhythms in behavior and in tissues in vivo. However, when isolated from the SCN, CLOCK-deficient peripheral tissues are reportedly arrhythmic, suggesting a fundamental difference in circadian clock function between SCN and peripheral tissues. Surprisingly, however, using luminometry and single-cell bioluminescence imaging of PER2 expression, we now find that CLOCK-deficient dispersed SCN neurons and peripheral cells exhibit similarly stable, autonomous circadian rhythms in vitro. In CLOCK-deficient fibroblasts, knockdown of Npas2 leads to arrhythmicity, suggesting that NPAS2 can compensate for loss of CLOCK in peripheral cells as well as in SCN. Our data overturn the notion of an SCN-specific role for NPAS2 in the molecular circadian clock, and instead indicate that, at the cellular level, the core loops of SCN neuron and peripheral cell circadian clocks are fundamentally similar.

  9. LoopIng: a template-based tool for predicting the structure of protein loops.

    KAUST Repository

    Messih, Mario Abdel

    2015-08-06

    Predicting the structure of protein loops is very challenging, mainly because they are not necessarily subject to strong evolutionary pressure. This implies that, unlike the rest of the protein, standard homology modeling techniques are not very effective in modeling their structure. However, loops are often involved in protein function, hence inferring their structure is important for predicting protein structure as well as function.We describe a method, LoopIng, based on the Random Forest automated learning technique, which, given a target loop, selects a structural template for it from a database of loop candidates. Compared to the most recently available methods, LoopIng is able to achieve similar accuracy for short loops (4-10 residues) and significant enhancements for long loops (11-20 residues). The quality of the predictions is robust to errors that unavoidably affect the stem regions when these are modeled. The method returns a confidence score for the predicted template loops and has the advantage of being very fast (on average: 1 min/loop).www.biocomputing.it/loopinganna.tramontano@uniroma1.itSupplementary data are available at Bioinformatics online.

  10. Boosted PWM open loop control of hydraulic proportional valves

    International Nuclear Information System (INIS)

    Amirante, R.; Innone, A.; Catalano, L.A.

    2008-01-01

    This paper presents an innovative open loop control technique for direct single stage hydraulic proportional valves whose response rate is significantly higher than that obtained by standard open loop control techniques, even comparable to more costly commercial closed loop systems. Different from standard open loop techniques, which provide the coil with a constant current proportional to the target position, the control strategy proposed in this paper employs the peak and hold (P and H) technique, widely used in Diesel engine modern supply systems, to boost the duty cycle value of the pulse width modulation (PWM) signal for a short time, namely during the spool displacement, while maintaining a lower duty cycle for holding the spool in the required opening position. The developed 'boosted PWM' technique only requires a low cost microcontroller, such as a peripheral interface controller (PIC) equipped with a metal oxide semiconductor (MOS) power driver. The PWM parameters are calibrated as a function of the spool displacement so as to maximize the response rate without introducing overshoots: the collected data are stored in the PIC. Different valve opening procedures with step response have been compared to demonstrate the merits of the proposed boosted PWM technique. No overshoots have been registered. Moreover, the proposed method is characterized by a significantly higher response rate with respect to a standard open loop control, which approximately has the same cost. Similar experimental tests show that the proposed boosted PWM technique has a response rate even higher than that provided by the more costly commercial closed loop system mounted on the valve, and it produces no overshoots

  11. Boosted PWM open loop control of hydraulic proportional valves

    Energy Technology Data Exchange (ETDEWEB)

    Amirante, R.; Catalano, L.A. [Dipartimento di Ingegneria Meccanica e Gestionale, Politecnico di Bari, Via Re David 200, 70125 Bari (Italy); Innone, A. [Universita degli Studi di Foggia, via Napoli, 25 Foggia (Italy)

    2008-08-15

    This paper presents an innovative open loop control technique for direct single stage hydraulic proportional valves whose response rate is significantly higher than that obtained by standard open loop control techniques, even comparable to more costly commercial closed loop systems. Different from standard open loop techniques, which provide the coil with a constant current proportional to the target position, the control strategy proposed in this paper employs the peak and hold (P and H) technique, widely used in Diesel engine modern supply systems, to boost the duty cycle value of the pulse width modulation (PWM) signal for a short time, namely during the spool displacement, while maintaining a lower duty cycle for holding the spool in the required opening position. The developed 'boosted PWM' technique only requires a low cost microcontroller, such as a peripheral interface controller (PIC) equipped with a metal oxide semiconductor (MOS) power driver. The PWM parameters are calibrated as a function of the spool displacement so as to maximize the response rate without introducing overshoots: the collected data are stored in the PIC. Different valve opening procedures with step response have been compared to demonstrate the merits of the proposed boosted PWM technique. No overshoots have been registered. Moreover, the proposed method is characterized by a significantly higher response rate with respect to a standard open loop control, which approximately has the same cost. Similar experimental tests show that the proposed boosted PWM technique has a response rate even higher than that provided by the more costly commercial closed loop system mounted on the valve, and it produces no overshoots. (author)

  12. Direct conscious telemetry recordings demonstrate increased renal sympathetic nerve activity in rats with chronic kidney disease

    Directory of Open Access Journals (Sweden)

    Ibrahim M Salman

    2015-08-01

    Full Text Available Chronic kidney disease (CKD is associated with sympathetic hyperactivity and impaired blood pressure control reflex responses, yet direct evidence demonstrating these features of autonomic dysfunction in conscious animals is still lacking. Here we measured renal sympathetic nerve activity (RSNA and mean arterial pressure (MAP using telemetry-based recordings in a rat model of CKD, the Lewis Polycystic Kidney (LPK rat, and assessed responses to chemoreflex activation and acute stress. Male LPK and Lewis control animals (total n=16 were instrumented for telemetric recording of RSNA and MAP. At 12–13 weeks-of-age, resting RSNA and MAP, sympathetic and haemodynamic responses to both peripheral (hypoxia: 10% O2 and central chemoreflex (hypercapnia: 7% CO2 activation and acute stress (open-field exposure, were measured. As indicators of renal function, urinary protein (UPro and creatinine (Ucr levels were assessed. LPK rats had higher resting RSNA (1.2±0.1 vs. 0.6±0.1 µV, p<0.05 and MAP (151±8 vs. 97±2 mmHg, p<0.05 compared to Lewis. MAP was negatively correlated with Ucr (r=-0.80, p=0.002 and positively correlated with RSNA (r=0.66, p=0.014, with multiple linear regression modeling indicating the strongest correlation was with Ucr. RSNA and MAP responses to activation of the central chemoreflex and open-field stress were reduced in the LPK relative to the Lewis (all p<0.05. This is the first description of dual conscious telemetry recording of RSNA and MAP in a genetic rodent model of CKD. Elevated RSNA is likely a key contributor to the marked hypertension in this model, while attenuated RSNA and MAP responses to central chemoreflex activation and acute stress in the LPK indicate possible deficits in the neural processing of autonomic outflows evoked by these sympathoexcitatory pathways.

  13. Loop Transfer Matrix and Loop Quantum Mechanics

    International Nuclear Information System (INIS)

    Savvidy, George K.

    2000-01-01

    The gonihedric model of random surfaces on a 3d Euclidean lattice has equivalent representation in terms of transfer matrix K(Q i ,Q f ), which describes the propagation of loops Q. We extend the previous construction of the loop transfer matrix to the case of nonzero self-intersection coupling constant κ. We introduce the loop generalization of Fourier transformation which allows to diagonalize transfer matrices, that depend on symmetric difference of loops only and express all eigenvalues of 3d loop transfer matrix through the correlation functions of the corresponding 2d statistical system. The loop Fourier transformation allows to carry out the analogy with quantum mechanics of point particles, to introduce conjugate loop momentum P and to define loop quantum mechanics. We also consider transfer matrix on 4d lattice which describes propagation of memebranes. This transfer matrix can also be diagonalized by using the generalized Fourier transformation, and all its eigenvalues are equal to the correlation functions of the corresponding 3d statistical system. In particular the free energy of the 4d membrane system is equal to the free energy of 3d gonihedric system of loops and is equal to the free energy of 2d Ising model. (author)

  14. Loop kinematics

    International Nuclear Information System (INIS)

    Migdal, A.A.

    1982-01-01

    Basic operators acting in the loop space are introduced. The topology of this space and properties of the Stokes type loop functionals are discussed. The parametrically invariant loop calculus developed here is used in the loop dynamics

  15. Peripheral neuropathy

    Science.gov (United States)

    ... peripheral; Neuritis - peripheral; Nerve disease; Polyneuropathy; Chronic pain - peripheral neuropathy ... Philadelphia, PA: Elsevier; 2016:chap 107. Shy ME. Peripheral neuropathies. In: Goldman L, Schafer AI, eds. Goldman's Cecil ...

  16. Activity of Tachykinin1-Expressing Pet1 Raphe Neurons Modulates the Respiratory Chemoreflex.

    Science.gov (United States)

    Hennessy, Morgan L; Corcoran, Andrea E; Brust, Rachael D; Chang, YoonJeung; Nattie, Eugene E; Dymecki, Susan M

    2017-02-15

    Homeostatic control of breathing, heart rate, and body temperature relies on circuits within the brainstem modulated by the neurotransmitter serotonin (5-HT). Mounting evidence points to specialized neuronal subtypes within the serotonergic neuronal system, borne out in functional studies, for the modulation of distinct facets of homeostasis. Such functional differences, read out at the organismal level, are likely subserved by differences among 5-HT neuron subtypes at the cellular and molecular levels, including differences in the capacity to coexpress other neurotransmitters such as glutamate, GABA, thyrotropin releasing hormone, and substance P encoded by the Tachykinin-1 ( Tac1 ) gene. Here, we characterize in mice a 5-HT neuron subtype identified by expression of Tac1 and the serotonergic transcription factor gene Pet1 , referred to as the Tac1-Pet1 neuron subtype. Transgenic cell labeling showed Tac1-Pet1 soma resident largely in the caudal medulla. Chemogenetic [clozapine -N- oxide (CNO)-hM4Di] perturbation of Tac1-Pet1 neuron activity blunted the ventilatory response of the respiratory CO 2 chemoreflex, which normally augments ventilation in response to hypercapnic acidosis to restore normal pH and PCO 2 Tac1-Pet1 axonal boutons were found localized to brainstem areas implicated in respiratory modulation, with highest density in motor regions. These findings demonstrate that the activity of a Pet1 neuron subtype with the potential to release both 5-HT and substance P is necessary for normal respiratory dynamics, perhaps via motor outputs that engage muscles of respiration and maintain airway patency. These Tac1-Pet1 neurons may act downstream of Egr2-Pet1 serotonergic neurons, which were previously established in respiratory chemoreception, but do not innervate respiratory motor nuclei. SIGNIFICANCE STATEMENT Serotonin (5-HT) neurons modulate physiological processes and behaviors as diverse as body temperature, respiration, aggression, and mood. Using

  17. Two-loop polygon Wilson loops in N = 4 SYM

    International Nuclear Information System (INIS)

    Anastasiou, C.; Brandhuber, A.; Heslop, P.; Spence, B.; Travaglini, G.; Khoze, V.V.

    2009-01-01

    We compute for the first time the two-loop corrections to arbitrary n-gon lightlike Wilson loops in N = 4 supersymmetric Yang-Mills theory, using efficient numerical methods. The calculation is motivated by the remarkable agreement between the finite part of planar six-point MHV amplitudes and hexagon Wilson loops which has been observed at two loops. At n = 6 we confirm that the ABDK/BDS ansatz must be corrected by adding a remainder function, which depends only on conformally invariant ratios of kinematic variables. We numerically compute remainder functions for n = 7,8 and verify dual conformal invariance. Furthermore, we study simple and multiple collinear limits of the Wilson loop remainder functions and demonstrate that they have precisely the form required by the collinear factorisation of the corresponding two-loop n-point amplitudes. The number of distinct diagram topologies contributing to the n-gon Wilson loops does not increase with n, and there is a fixed number of 'master integrals', which we have computed. Thus we have essentially computed general polygon Wilson loops, and if the correspondence with amplitudes continues to hold, all planar n-point two-loop MHV amplitudes in the N = 4 theory.

  18. Percutaneous retrieval of an intracardiac central venous port fragment using snare with triple loops

    Directory of Open Access Journals (Sweden)

    Mehdi Ghaderian

    2015-01-01

    Full Text Available Peripherally inserted venous ports fracture with embolization in patients who received chemotherapy is a serious and rare complication, and few cases have been reported in children. We report a successful endovascular technique using a snare for retrieving broken peripherally inserted venous ports in a child for chemotherapy. Catheter fragments may cause complications such as cardiac perforation, arrhythmias, sepsis, and pulmonary embolism. A 12-year-old female received chemotherapy for acute lymphocytic leukemia through a central venous port implanted into her right subclavian area. The patient completed chemotherapy without complications 6 months ago. Venous port was accidentally fractured during its removal. Chest radiographs of the patient revealed intracardiac catheter fragment extending from the right subclavian to the right atrium (RA and looping in the RA. The procedure was performed under ketamine and midazolam anesthesia and fluoroscopic guidance using a percutaneous femoral vein approach. A snare with triple loops (10 mm in diameter was used to successfully retrieve the catheter fragments without any complication. Percutaneous transcatheter retrieval of catheter fragments is occasionally extremely useful and should be considered by interventional cardiologists for retrieving migrated catheters and can be chosen before resorting to surgery, which has potential risks related to thoracotomy, cardiopulmonary bypass, and general anesthesia.

  19. Alternative loop rings

    CERN Document Server

    Goodaire, EG; Polcino Milies, C

    1996-01-01

    For the past ten years, alternative loop rings have intrigued mathematicians from a wide cross-section of modern algebra. As a consequence, the theory of alternative loop rings has grown tremendously. One of the main developments is the complete characterization of loops which have an alternative but not associative, loop ring. Furthermore, there is a very close relationship between the algebraic structures of loop rings and of group rings over 2-groups. Another major topic of research is the study of the unit loop of the integral loop ring. Here the interaction between loop rings and group ri

  20. Cardiovascular responses to microinjection of L-glutamate into the NTS in AV3V-lesioned rats.

    Science.gov (United States)

    Vieira, Alexandre Antonio; Colombari, Eduardo; De Luca, Laurival A; de Almeida Colombari, Débora Simões; Menani, José V

    2004-10-29

    The excitatory amino acid L-glutamate injected into the nucleus of the solitary tract (NTS) in unanesthetized rats similar to peripheral chemoreceptor activation increases mean arterial pressure (MAP) and reduces heart rate. In this study, we investigated the effects of acute (1 day) and chronic (15 days) electrolytic lesions of the preoptic-periventricular tissue surrounding the anteroventral third ventricle (AV3V region) on the pressor and bradycardic responses induced by injections of L-glutamate into the NTS or peripheral chemoreceptor activation in unanesthetized rats. Male Holtzman rats with sham or electrolytic AV3V lesions and a stainless steel cannula implanted into the NTS were used. Differently from the pressor responses (28+/-3 mm Hg) produced by injections into the NTS of sham-lesioned rats, L-glutamate (5 nmol/100 nl) injected into the NTS reduced MAP (-26+/-8 mm Hg) or produced no effect (2+/-7 mm Hg) in acute and chronic AV3V-lesioned rats, respectively. The bradycardia to l-glutamate into the NTS and the cardiovascular responses to chemoreflex activation with intravenous potassium cyanide or to baroreflex activation with intravenous phenylephrine or sodium nitroprusside were not modified by AV3V lesions. The results show that the integrity of the AV3V region is essential for the pressor responses to L-glutamate into the NTS but not for the pressor responses to chemoreflex activation, suggesting dissociation between the central mechanisms involved in these responses.

  1. A Model of Electrically Stimulated Auditory Nerve Fiber Responses with Peripheral and Central Sites of Spike Generation

    DEFF Research Database (Denmark)

    Joshi, Suyash Narendra; Dau, Torsten; Epp, Bastian

    2017-01-01

    . A single ANF is modeled as a network of two exponential integrateand-fire point-neuron models, referred to as peripheral and central axons of the ANF. The peripheral axon is excited by the cathodic charge, inhibited by the anodic charge, and exhibits longer spike latencies than the central axon......A computational model of cat auditory nerve fiber (ANF) responses to electrical stimulation is presented. The model assumes that (1) there exist at least two sites of spike generation along the ANF and (2) both an anodic (positive) and a cathodic (negative) charge in isolation can evoke a spike......; the central axon is excited by the anodic charge, inhibited by the cathodic charge, and exhibits shorter spike latencies than the peripheral axon. The model also includes subthreshold and suprathreshold adaptive feedback loops which continuously modify the membrane potential and can account for effects...

  2. Random walk loop soups and conformal loop ensembles

    NARCIS (Netherlands)

    van de Brug, T.; Camia, F.; Lis, M.

    2016-01-01

    The random walk loop soup is a Poissonian ensemble of lattice loops; it has been extensively studied because of its connections to the discrete Gaussian free field, but was originally introduced by Lawler and Trujillo Ferreras as a discrete version of the Brownian loop soup of Lawler and Werner, a

  3. Regulation of Breathing and Autonomic Outflows by Chemoreceptors

    Science.gov (United States)

    Guyenet, Patrice G.

    2016-01-01

    Lung ventilation fluctuates widely with behavior but arterial PCO2 remains stable. Under normal conditions, the chemoreflexes contribute to PaCO2 stability by producing small corrective cardiorespiratory adjustments mediated by lower brainstem circuits. Carotid body (CB) information reaches the respiratory pattern generator (RPG) via nucleus solitarius (NTS) glutamatergic neurons which also target rostral ventrolateral medulla (RVLM) presympathetic neurons thereby raising sympathetic nerve activity (SNA). Chemoreceptors also regulate presympathetic neurons and cardiovagal preganglionic neurons indirectly via inputs from the RPG. Secondary effects of chemoreceptors on the autonomic outflows result from changes in lung stretch afferent and baroreceptor activity. Central respiratory chemosensitivity is caused by direct effects of acid on neurons and indirect effects of CO2 via astrocytes. Central respiratory chemoreceptors are not definitively identified but the retrotrapezoid nucleus (RTN) is a particularly strong candidate. The absence of RTN likely causes severe central apneas in congenital central hypoventilation syndrome. Like other stressors, intense chemosensory stimuli produce arousal and activate circuits that are wake- or attention-promoting. Such pathways (e.g., locus coeruleus, raphe, and orexin system) modulate the chemoreflexes in a state-dependent manner and their activation by strong chemosensory stimuli intensifies these reflexes. In essential hypertension, obstructive sleep apnea and congestive heart failure, chronically elevated CB afferent activity contributes to raising SNA but breathing is unchanged or becomes periodic (severe CHF). Extreme CNS hypoxia produces a stereotyped cardiorespiratory response (gasping, increased SNA). The effects of these various pathologies on brainstem cardiorespiratory networks are discussed, special consideration being given to the interactions between central and peripheral chemoreflexes. PMID:25428853

  4. Renormalization of loop functions for all loops

    International Nuclear Information System (INIS)

    Brandt, R.A.; Neri, F.; Sato, M.

    1981-01-01

    It is shown that the vacuum expectation values W(C 1 ,xxx, C/sub n/) of products of the traces of the path-ordered phase factors P exp[igcontour-integral/sub C/iA/sub μ/(x)dx/sup μ/] are multiplicatively renormalizable in all orders of perturbation theory. Here A/sub μ/(x) are the vector gauge field matrices in the non-Abelian gauge theory with gauge group U(N) or SU(N), and C/sub i/ are loops (closed paths). When the loops are smooth (i.e., differentiable) and simple (i.e., non-self-intersecting), it has been shown that the generally divergent loop functions W become finite functions W when expressed in terms of the renormalized coupling constant and multiplied by the factors e/sup -K/L(C/sub i/), where K is linearly divergent and L(C/sub i/) is the length of C/sub i/. It is proved here that the loop functions remain multiplicatively renormalizable even if the curves have any finite number of cusps (points of nondifferentiability) or cross points (points of self-intersection). If C/sub γ/ is a loop which is smooth and simple except for a single cusp of angle γ, then W/sub R/(C/sub γ/) = Z(γ)W(C/sub γ/) is finite for a suitable renormalization factor Z(γ) which depends on γ but on no other characteristic of C/sub γ/. This statement is made precise by introducing a regularization, or via a loop-integrand subtraction scheme specified by a normalization condition W/sub R/(C-bar/sub γ/) = 1 for an arbitrary but fixed loop C-bar/sub γ/. Next, if C/sub β/ is a loop which is smooth and simple except for a cross point of angles β, then W(C/sub β/) must be renormalized together with the loop functions of associated sets S/sup i//sub β/ = ]C/sup i/ 1 ,xxx, C/sup i//sub p/i] (i = 2,xxx,I) of loops C/sup i//sub q/ which coincide with certain parts of C/sub β/equivalentC 1 1 . Then W/sub R/(S/sup i//sub β/) = Z/sup i/j(β)W(S/sup j//sub β/) is finite for a suitable matrix Z/sup i/j

  5. Distribution of Fos-Like Immunoreactivity, Catecholaminergic and Serotoninergic Neurons Activated by the Laryngeal Chemoreflex in the Medulla Oblongata of Rats.

    Science.gov (United States)

    Wang, Xiaolu; Guo, Ruichen; Zhao, Wenjing

    2015-01-01

    The laryngeal chemoreflex (LCR) induces apnea, glottis closure, bradycardia and hypertension in young and maturing mammals. We examined the distribution of medullary nuclei that are activated by the LCR and used immunofluorescent detection of Fos protein as a cellular marker for neuronal activation to establish that the medullary catecholaminergic and serotoninergic neurons participate in the modulation of the LCR. The LCR was elicited by the infusion of KCl-HCl solution into the laryngeal lumen of adult rats in the experimental group, whereas the control group received the same surgery but no infusion. In comparison, the number of regions of Fos-like immunoreactivity (FLI) that were activated by the LCR significantly increased in the nucleus of the solitary tract (NTS), the vestibular nuclear complex (VNC), the loose formation of the nucleus ambiguus (AmbL), the rostral ventral respiratory group (RVRG), the ventrolateral reticular complex (VLR), the pre-Bötzinger complex (PrBöt), the Bötzinger complex (Böt), the spinal trigeminal nucleus (SP5), and the raphe obscurus nucleus (ROb) bilaterally from the medulla oblongata. Furthermore, 12.71% of neurons with FLI in the dorsolateral part of the nucleus of the solitary tract (SolDL) showed tyrosine hydroxylase-immunoreactivity (TH-ir, catecholaminergic), and 70.87% of neurons with FLI in the ROb were serotoninergic. Our data demonstrated the distribution of medullary nuclei that were activated by the LCR, and further demonstrated that catecholaminergic neurons of the SolDL and serotoninergic neurons of the ROb were activated by the LCR, indicating the potential central pathway of the LCR.

  6. Distribution of Fos-Like Immunoreactivity, Catecholaminergic and Serotoninergic Neurons Activated by the Laryngeal Chemoreflex in the Medulla Oblongata of Rats.

    Directory of Open Access Journals (Sweden)

    Xiaolu Wang

    Full Text Available The laryngeal chemoreflex (LCR induces apnea, glottis closure, bradycardia and hypertension in young and maturing mammals. We examined the distribution of medullary nuclei that are activated by the LCR and used immunofluorescent detection of Fos protein as a cellular marker for neuronal activation to establish that the medullary catecholaminergic and serotoninergic neurons participate in the modulation of the LCR. The LCR was elicited by the infusion of KCl-HCl solution into the laryngeal lumen of adult rats in the experimental group, whereas the control group received the same surgery but no infusion. In comparison, the number of regions of Fos-like immunoreactivity (FLI that were activated by the LCR significantly increased in the nucleus of the solitary tract (NTS, the vestibular nuclear complex (VNC, the loose formation of the nucleus ambiguus (AmbL, the rostral ventral respiratory group (RVRG, the ventrolateral reticular complex (VLR, the pre-Bötzinger complex (PrBöt, the Bötzinger complex (Böt, the spinal trigeminal nucleus (SP5, and the raphe obscurus nucleus (ROb bilaterally from the medulla oblongata. Furthermore, 12.71% of neurons with FLI in the dorsolateral part of the nucleus of the solitary tract (SolDL showed tyrosine hydroxylase-immunoreactivity (TH-ir, catecholaminergic, and 70.87% of neurons with FLI in the ROb were serotoninergic. Our data demonstrated the distribution of medullary nuclei that were activated by the LCR, and further demonstrated that catecholaminergic neurons of the SolDL and serotoninergic neurons of the ROb were activated by the LCR, indicating the potential central pathway of the LCR.

  7. A complete two-loop, five-gluon helicity amplitude in Yang-Mills theory

    International Nuclear Information System (INIS)

    Badger, Simon; Mogull, Gustav; Ochirov, Alexander; O’Connell, Donal

    2015-01-01

    We compute the integrand of the full-colour, two-loop, five-gluon scattering amplitude in pure Yang-Mills theory with all helicities positive, using generalized unitarity cuts. Tree-level BCJ relations, satisfied by amplitudes appearing in the cuts, allow us to deduce all the necessary non-planar information for the full-colour amplitude from known planar data. We present our result in terms of irreducible numerators, with colour factors derived from the multi-peripheral colour decomposition. Finally, the leading soft divergences are checked to reproduce the expected infrared behaviour.

  8. A complete two-loop, five-gluon helicity amplitude in Yang-Mills theory

    Energy Technology Data Exchange (ETDEWEB)

    Badger, Simon; Mogull, Gustav; Ochirov, Alexander [Higgs Centre for Theoretical Physics, School of Physics and Astronomy, University of Edinburgh, Edinburgh EH9 3JZ, Scotland (United Kingdom); O’Connell, Donal [Higgs Centre for Theoretical Physics, School of Physics and Astronomy, University of Edinburgh, Edinburgh EH9 3JZ, Scotland (United Kingdom); Kavli Institute for Theoretical Physics, University of California, Santa Barbara, CA 93106-4030 (United States)

    2015-10-09

    We compute the integrand of the full-colour, two-loop, five-gluon scattering amplitude in pure Yang-Mills theory with all helicities positive, using generalized unitarity cuts. Tree-level BCJ relations, satisfied by amplitudes appearing in the cuts, allow us to deduce all the necessary non-planar information for the full-colour amplitude from known planar data. We present our result in terms of irreducible numerators, with colour factors derived from the multi-peripheral colour decomposition. Finally, the leading soft divergences are checked to reproduce the expected infrared behaviour.

  9. Two-loop hard-thermal-loop thermodynamics with quarks

    International Nuclear Information System (INIS)

    Andersen, Jens O.; Petitgirard, Emmanuel; Strickland, Michael

    2004-01-01

    We calculate the quark contribution to the free energy of a hot quark-gluon plasma to two-loop order using hard-thermal-loop (HTL) perturbation theory. All ultraviolet divergences can be absorbed into renormalizations of the vacuum energy and the HTL quark and gluon mass parameters. The quark and gluon HTL mass parameters are determined self-consistently by a variational prescription. Combining the quark contribution with the two-loop HTL perturbation theory free energy for pure glue we obtain the total two-loop QCD free energy. Comparisons are made with lattice estimates of the free energy for N f =2 and with exact numerical results obtained in the large-N f limit

  10. LoopIng: a template-based tool for predicting the structure of protein loops.

    KAUST Repository

    Messih, Mario Abdel; Lepore, Rosalba; Tramontano, Anna

    2015-01-01

    ) and significant enhancements for long loops (11-20 residues). The quality of the predictions is robust to errors that unavoidably affect the stem regions when these are modeled. The method returns a confidence score for the predicted template loops and has

  11. Neocortical electrical stimulation for epilepsy : Closed-loop versus open-loop

    NARCIS (Netherlands)

    Vassileva, Albena; van Blooijs, Dorien; Leijten, Frans; Huiskamp, Geertjan

    2018-01-01

    The aim of this review is to evaluate whether open-loop or closed-loop neocortical electrical stimulation should be the preferred approach to manage seizures in intractable epilepsy. Twenty cases of open-loop neocortical stimulation with an implanted device have been reported, in 5 case studies.

  12. A multiple-pass ring oscillator based dual-loop phase-locked loop

    International Nuclear Information System (INIS)

    Chen Danfeng; Ren Junyan; Deng Jingjing; Li Wei; Li Ning

    2009-01-01

    A dual-loop phase-locked loop (PLL) for wideband operation is proposed. The dual-loop architecture combines a coarse-tuning loop with a fine-tuning one, enabling a wide tuning range and low voltage-controlled oscillator (VCO) gain without poisoning phase noise and reference spur suppression performance. An analysis of the phase noise and reference spur of the dual-loop PLL is emphasized. A novel multiple-pass ring VCO is designed for the dual-loop application. It utilizes both voltage-control and current-control simultaneously in the delay cell. The PLL is fabricated in Jazz 0.18-μm RF CMOS technology. The measured tuning range is from 4.2 to 5.9 GHz. It achieves a low phase noise of -99 dBc/Hz - 1 MHz offset from a 5.5 GHz carrier.

  13. A multiple-pass ring oscillator based dual-loop phase-locked loop

    Energy Technology Data Exchange (ETDEWEB)

    Chen Danfeng; Ren Junyan; Deng Jingjing; Li Wei; Li Ning, E-mail: dfchen@fudan.edu.c [State Key Laboratory of ASIC and System, Fudan University, Shanghai 201203 (China)

    2009-10-15

    A dual-loop phase-locked loop (PLL) for wideband operation is proposed. The dual-loop architecture combines a coarse-tuning loop with a fine-tuning one, enabling a wide tuning range and low voltage-controlled oscillator (VCO) gain without poisoning phase noise and reference spur suppression performance. An analysis of the phase noise and reference spur of the dual-loop PLL is emphasized. A novel multiple-pass ring VCO is designed for the dual-loop application. It utilizes both voltage-control and current-control simultaneously in the delay cell. The PLL is fabricated in Jazz 0.18-{mu}m RF CMOS technology. The measured tuning range is from 4.2 to 5.9 GHz. It achieves a low phase noise of -99 dBc/Hz - 1 MHz offset from a 5.5 GHz carrier.

  14. Sequence-structure relationships in RNA loops: establishing the basis for loop homology modeling.

    Science.gov (United States)

    Schudoma, Christian; May, Patrick; Nikiforova, Viktoria; Walther, Dirk

    2010-01-01

    The specific function of RNA molecules frequently resides in their seemingly unstructured loop regions. We performed a systematic analysis of RNA loops extracted from experimentally determined three-dimensional structures of RNA molecules. A comprehensive loop-structure data set was created and organized into distinct clusters based on structural and sequence similarity. We detected clear evidence of the hallmark of homology present in the sequence-structure relationships in loops. Loops differing by structures. Thus, our results support the application of homology modeling for RNA loop model building. We established a threshold that may guide the sequence divergence-based selection of template structures for RNA loop homology modeling. Of all possible sequences that are, under the assumption of isosteric relationships, theoretically compatible with actual sequences observed in RNA structures, only a small fraction is contained in the Rfam database of RNA sequences and classes implying that the actual RNA loop space may consist of a limited number of unique loop structures and conserved sequences. The loop-structure data sets are made available via an online database, RLooM. RLooM also offers functionalities for the modeling of RNA loop structures in support of RNA engineering and design efforts.

  15. LOOP CALCULUS AND BELIEF PROPAGATION FOR Q-ARY ALPHABET: LOOP TOWER

    Energy Technology Data Exchange (ETDEWEB)

    CHERTKOV, MICHAEL [Los Alamos National Laboratory; CHERNYAK, VLADIMIR [Los Alamos National Laboratory

    2007-01-10

    Loop calculus introduced in [1], [2] constitutes a new theoretical tool that explicitly expresses symbol Maximum-A-Posteriori (MAP) solution of a general statistical inference problem via a solution of the Belief Propagation (BP) equations. This finding brought a new significance to the BP concept, which in the past was thought of as just a loop-free approximation. In this paper they continue a discussion of the Loop Calculus, partitioning the results into three Sections. In Section 1 they introduce a new formulation of the Loop Calculus in terms of a set of transformations (gauges) that keeping the partition function of the problem invariant. The full expression contains two terms referred to as the 'ground state' and 'excited states' contributions. The BP equations are interpreted as a special (BP) gauge fixing condition that emerges as a special orthogonality constraint between the ground state and excited states, which also selects loop contributions as the only surviving ones among the excited states. In Section 2 they demonstrate how the invariant interpretation of the Loop Calculus, introduced in Section 1, allows a natural extension to the case of a general q-ary alphabet, this is achieved via a loop tower sequential construction. The ground level in the tower is exactly equivalent to assigning one color (out of q available) to the 'ground state' and considering all 'excited' states colored in the remaining (q-1) colors, according to the loop calculus rule. Sequentially, the second level in the tower corresponds to selecting a loop from the previous step, colored in (q-1) colors, and repeating the same ground vs excited states splitting procedure into one and (q-2) colors respectively. The construction proceeds till the full (q-1)-levels deep loop tower (and the corresponding contributions to the partition function) are established. In Section 3 they discuss an ultimate relation between the loop calculus and the Bethe

  16. Development of regenerative peripheral nerve interfaces for motor control of neuroprosthetic devices

    Science.gov (United States)

    Kemp, Stephen W. P.; Urbanchek, Melanie G.; Irwin, Zachary T.; Chestek, Cynthia A.; Cederna, Paul S.

    2017-05-01

    Traumatic peripheral nerve injuries suffered during amputation commonly results in debilitating neuropathic pain in the affected limb. Modern prosthetic technologies allow for intuitive, simultaneous control of multiple degrees of freedom. However, these state-of-the-art devices require separate, independent control signals for each degree of freedom, which is currently not possible. As a result, amputees reject up to 75% of myoelectric devices preferring instead to use body-powered artificial limbs which offer subtle sensory feedback. Without meaningful and intuitive sensory feedback, even the most advanced myoelectric prostheses remain insensate, burdensome, and are associated with enormous cognitive demand and mental fatigue. The ideal prosthetic device is one which is capable of providing intuitive somatosensory feedback essential for interaction with the environment. Critical to the design of such a bioprosthetic device is the development of a reliable biologic interface between human and machine. This ideal patient-prosthetic interface allows for transmission of both afferent somatosensory information and efferent motor signals for a closed-loop feedback system of neural control. Our lab has developed the Regenerative Peripheral Nerve Interface (RPNI) as a biologic nerve interface designed for stable integration of a prosthetic device with transected peripheral nerves in a residual limb. The RPNI is constructed by surgically implanting the distal end of a transected peripheral nerve into an autogenous muscle graft. Animal experiments in our lab have shown recording of motor signals from RPNI's implanted into both rodents and monkeys. Here, we achieve high amplitude EMG signals with a high signal to noise (SNR) ratio.

  17. Introduction to Loop Heat Pipes

    Science.gov (United States)

    Ku, Jentung

    2015-01-01

    This is the presentation file for the short course Introduction to Loop Heat Pipes, to be conducted at the 2015 Thermal Fluids and Analysis Workshop, August 3-7, 2015, Silver Spring, Maryland. This course will discuss operating principles and performance characteristics of a loop heat pipe. Topics include: 1) pressure profiles in the loop; 2) loop operating temperature; 3) operating temperature control; 4) loop startup; 4) loop shutdown; 5) loop transient behaviors; 6) sizing of loop components and determination of fluid inventory; 7) analytical modeling; 8) examples of flight applications; and 9) recent LHP developments.

  18. Reactor loops at Chalk River

    International Nuclear Information System (INIS)

    Sochaski, R.O.

    1962-07-01

    This report describes broadly the nine in-reactor loops, and their components, located in and around the NRX and NRU reactors at Chalk River. First an introduction and general description is given of the loops and their function, supplemented with a table outlining some loop specifications and nine simplified flow sheets, one for each individual loop. The report then proceeds to classify each loop into two categories, the 'main loop circuit' and the 'auxiliary circuit', and descriptions are given of each circuit's components in turn. These components, in part, are comprised of the main loop pumps, the test section, loop heaters, loop coolers, delayed-neutron monitors, surge tank, Dowtherm coolers, loop piping. Here again photographs, drawings and tables are included to provide a clearer understanding of the descriptive literature and to include, in tables, some specifications of the more important components in each loop. (author)

  19. Distribution of sizes of erased loops for loop-erased random walks

    OpenAIRE

    Dhar, Deepak; Dhar, Abhishek

    1997-01-01

    We study the distribution of sizes of erased loops for loop-erased random walks on regular and fractal lattices. We show that for arbitrary graphs the probability $P(l)$ of generating a loop of perimeter $l$ is expressible in terms of the probability $P_{st}(l)$ of forming a loop of perimeter $l$ when a bond is added to a random spanning tree on the same graph by the simple relation $P(l)=P_{st}(l)/l$. On $d$-dimensional hypercubical lattices, $P(l)$ varies as $l^{-\\sigma}$ for large $l$, whe...

  20. PHOTOSPHERIC PROPERTIES OF WARM EUV LOOPS AND HOT X-RAY LOOPS

    Energy Technology Data Exchange (ETDEWEB)

    Kano, R. [National Astronomical Observatory of Japan, 2-21-1 Osawa, Mitaka, Tokyo 181-8588 (Japan); Ueda, K. [Department of Astronomy, Graduate School of Science, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Tsuneta, S., E-mail: ryouhei.kano@nao.ac.jp [Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency, 3-1-1 Yoshinodai, Chuo, Sagamihara, Kanagawa 252-5210 (Japan)

    2014-02-20

    We investigate the photospheric properties (vector magnetic fields and horizontal velocity) of a well-developed active region, NOAA AR 10978, using the Hinode Solar Optical Telescope specifically to determine what gives rise to the temperature difference between ''warm loops'' (1-2 MK), which are coronal loops observed in EUV wavelengths, and ''hot loops'' (>3 MK), coronal loops observed in X-rays. We found that outside sunspots, the magnetic filling factor in the solar network varies with location and is anti-correlated with the horizontal random velocity. If we accept that the observed magnetic features consist of unresolved magnetic flux tubes, this anti-correlation can be explained by the ensemble average of flux-tube motion driven by small-scale random flows. The observed data are consistent with a flux tube width of ∼77 km and horizontal flow at ∼2.6 km s{sup –1} with a spatial scale of ∼120 km. We also found that outside sunspots, there is no significant difference between warm and hot loops either in the magnetic properties (except for the inclination) or in the horizontal random velocity at their footpoints, which are identified with the Hinode X-Ray Telescope and the Transition Region and Coronal Explorer. The energy flux injected into the coronal loops by the observed photospheric motion of the magnetic fields is estimated to be 2 × 10{sup 6} erg s{sup –1} cm{sup –2}, which is the same for both warm and hot loops. This suggests that coronal properties (e.g., loop length) play a more important role in giving rise to temperature differences of active-region coronal loops than photospheric parameters.

  1. Vasculitic peripheral neuropathy

    Directory of Open Access Journals (Sweden)

    Mona Amini

    2014-02-01

    Full Text Available Primary systemic vasculitis in pre-capillary arteries is associated with peripheral neuropathy. In some types of systematic vasculitis about 60 % of patients have peripheral nervous system (PNS involvement. In vasculitic peripheral neuropathies (VPN a necrotizing and inflammatory process leads to narrowing of vasa nervorum lumen and eventually the appearance of ischemic lesions in peripheral nerves. Some features might be suggestive of VPN, like: axonal nerve degeneration, wallerian-like degeneration, and diameter irregularity of nerve. Peripheral nervous system (PNS destruction during systemic vasculitides should be considered, due to its frequency and early occurrence in vasculitis progression. The first line treatment of non systematic VPNs is corticosteroid agents, but these drugs might worsen the VPNs or systemic vasculitis.

  2. Using Arrays of Microelectrodes Implanted in Residual Peripheral Nerves to Provide Dextrous Control of, and Modulated Sensory Feedback from, a Hand Prosthesis

    Science.gov (United States)

    2015-10-01

    extended that work by investigating multiple aspects important for developing future bidirectional neural prostheses based on high-count microelectrode...Fan J M, Kao J C, Stavisky S D, Ryu S and Shenoy K 2012 A recurrent neural network for closed-loop intracortical brain-machine interface decoders J...Peripheral Nerve Interface, Prosthetic Hand, Neural Prosthesis, Sensory Feedback, Micro-stimulation, Electrophysiology, Action Potentials, Micro

  3. Multiple Flow Loop SCADA System Implemented on the Production Prototype Loop

    Energy Technology Data Exchange (ETDEWEB)

    Baily, Scott A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dalmas, Dale Allen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Wheat, Robert Mitchell [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Woloshun, Keith Albert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dale, Gregory E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-11-16

    The following report covers FY 15 activities to develop supervisory control and data acquisition (SCADA) system for the Northstar Moly99 production prototype gas flow loop. The goal of this effort is to expand the existing system to include a second flow loop with a larger production-sized blower. Besides testing the larger blower, this system will demonstrate the scalability of our solution to multiple flow loops.

  4. Peripheral biomarkers revisited: integrative profiling of peripheral samples for psychiatric research.

    Science.gov (United States)

    Hayashi-Takagi, Akiko; Vawter, Marquis P; Iwamoto, Kazuya

    2014-06-15

    Peripheral samples, such as blood and skin, have been used for decades in psychiatric research as surrogates for central nervous system samples. Although the validity of the data obtained from peripheral samples has been questioned and other state-of-the-art techniques, such as human brain imaging, genomics, and induced pluripotent stem cells, seem to reduce the value of peripheral cells, accumulating evidence has suggested that revisiting peripheral samples is worthwhile. Here, we re-evaluate the utility of peripheral samples and argue that establishing an understanding of the common signaling and biological processes in the brain and peripheral samples is required for the validity of such models. First, we present an overview of the available types of peripheral cells and describe their advantages and disadvantages. We then briefly summarize the main achievements of omics studies, including epigenome, transcriptome, proteome, and metabolome analyses, as well as the main findings of functional cellular assays, the results of which imply that alterations in neurotransmission, metabolism, the cell cycle, and the immune system may be partially responsible for the pathophysiology of major psychiatric disorders such as schizophrenia. Finally, we discuss the future utility of peripheral samples for the development of biomarkers and tailor-made therapies, such as multimodal assays that are used as a battery of disease and trait pathways and that might be potent and complimentary tools for use in psychiatric research. © 2013 Society of Biological Psychiatry Published by Society of Biological Psychiatry All rights reserved.

  5. On loop extensions and cohomology of loops

    OpenAIRE

    Benítez, Rolando Jiménez; Meléndez, Quitzeh Morales

    2015-01-01

    In this paper are defined cohomology-like groups that classify loop extensions satisfying a given identity in three variables for association identities, and in two variables for the case of commutativity. It is considered a large amount of identities. This groups generalize those defined in works of Nishigori [2] and of Jhonson and Leedham-Green [4]. It is computed the number of metacyclic extensions for trivial action of the quotient on the kernel in one particular case for left Bol loops a...

  6. Rapid Simulation of Flat Knitting Loops Based On the Yarn Texture and Loop Geometrical Model

    Directory of Open Access Journals (Sweden)

    Lu Zhiwen

    2017-06-01

    Full Text Available In order to create realistic loop primitives suitable for the fast computer-aided design (CAD of the flat knitted fabric, we have a research on the geometric model of the loop as well as the variation of the loop surface. Establish the texture variation model based on the changing process from the normal yarn to loop that provides the realistic texture of the simulative loop. Then optimize the simulative loop based on illumination variation. This paper develops the computer program with the optimization algorithm and achieves the loop simulation of different yarns to verify the feasibility of the proposed algorithm. Our work provides a fast CAD of the flat knitted fabric with loop simulation, and it is not only more realistic but also material adjustable. Meanwhile it also provides theoretical value for the flat knitted fabric computer simulation.

  7. Cardiorespiratory interactions in neural circulatory control in humans.

    Science.gov (United States)

    Shamsuzzaman, A S; Somers, V K

    2001-06-01

    The reflex mechanisms and interactions described in this overview provide some explanation for the range of neural circulatory responses evident during changes in breathing. The effects described represent the integrated responses to activation of several reflex mechanisms, including peripheral and central chemoreflexes, arterial baroreflexes, pulmonary stretch receptors, and ventricular mechanoreceptors. These interactions occur on a dynamic basis and the transfer characteristics of any single interaction are, in all likelihood, also highly dynamic. Nevertheless, it is only by attempting to understand individual reflexes and their modulating influences that a more thorough understanding of the responses to complex phenomena such as hyperventilation, apnea, and obstructive sleep apnea can be better understood.

  8. Peripheral reactions

    International Nuclear Information System (INIS)

    Greiner, D.

    1978-01-01

    Peripheral collisions, that is, collisions involving a small amount of overlap of nuclear matter, are discussed including inclusive interactions, the magnitude of the peripheral cross section, fragmentation, a compilation of experiments and available data, limiting fragmentation, factorization, some models, fragment momentum distributions, and future research directions

  9. A novel heart rate control model provides insights linking LF-HRV behavior to the open-loop gain.

    Science.gov (United States)

    Dvir, Hila; Bobrovsky, Ben Zion; Gabbay, Uri

    2013-09-20

    Low-frequency heart rate variability (LF-HRV) at rest has already been successfully modeled as self-sustained oscillations in a nonlinear control loop, but these models fail to simulate LF-HRV decreases either during aerobic exercise or in heart failure patients. Following control engineering practices, we assume the existence of a biological excitation (dither) within the heart rate control loop that softens the nonlinearity and studied LF-HRV behavior in a dither-embedded model. We adopted the Ottesen model with some revisions and induced a dither of high-frequency stochastic perturbations. We simulated scenarios of a healthy subject at rest and during aerobic exercise (by decreasing peripheral vascular resistance) and a heart failure patient (by decreasing stroke volume). The simulations resembled physiological LF-HRV behavior, i.e., LF-HRV decreased during aerobic exercise and in the heart failure patient. The simulations exhibited LF-HRV dependency on the open-loop gain, which is related to the product of the feedback gain and the feed forward gain. We are the first to demonstrate that LF-HRV may be dependent on the open-loop gain. Accordingly, reduced open-loop gain results in decreased LF-HRV, and vice versa. Our findings explain a well-known but unexplained observed phenomenon of reduced LF-HRV both in heart failure patients and in healthy subjects performing aerobic exercise. These findings have implications on how changes in LF-HRV can be interpreted physiologically, a necessary step towards the clinical utilization of LF-HRV. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  10. Multi-loop PWR modeling and hardware-in-the-loop testing using ACSL

    International Nuclear Information System (INIS)

    Thomas, V.M.; Heibel, M.D.; Catullo, W.J.

    1989-01-01

    Westinghouse has developed an Advanced Digital Feedwater Control System (ADFCS) which is aimed at reducing feedwater related reactor trips through improved control performance for pressurized water reactor (PWR) power plants. To support control system setpoint studies and functional design efforts for the ADFCS, an ACSL based model of the nuclear steam supply system (NSSS) of a Westinghouse (PWR) was generated. Use of this plant model has been extended from system design to system testing through integration of the model into a Hardware-in-Loop test environment for the ADFCS. This integration includes appropriate interfacing between a Gould SEL 32/87 computer, upon which the plant model executes in real time, and the Westinghouse Distributed Processing family (WDPF) test hardware. A development program has been undertaken to expand the existing ACSL model to include capability to explicitly model multiple plant loops, steam generators, and corresponding feedwater systems. Furthermore, the program expands the ADFCS Hardware-in-Loop testing to include the multi-loop plant model. This paper provides an overview of the testing approach utilized for the ADFCS with focus on the role of Hardware-in-Loop testing. Background on the plant model, methodology and test environment is also provided. Finally, an overview is presented of the program to expand the model and associated Hardware-in-Loop test environment to handle multiple loops

  11. Random walk loop soup

    OpenAIRE

    Lawler, Gregory F.; Ferreras, José A. Trujillo

    2004-01-01

    The Brownian loop soup introduced in Lawler and Werner (2004) is a Poissonian realization from a sigma-finite measure on unrooted loops. This measure satisfies both conformal invariance and a restriction property. In this paper, we define a random walk loop soup and show that it converges to the Brownian loop soup. In fact, we give a strong approximation result making use of the strong approximation result of Koml\\'os, Major, and Tusn\\'ady. To make the paper self-contained, we include a proof...

  12. Neutron transport in irradiation loops (IRENE loop)

    International Nuclear Information System (INIS)

    Sarsam, Maher.

    1980-09-01

    This thesis is composed of two parts with different aspects. Part one is a technical description of the loop and its main ancillary facilities as well as of the safety and operational regulations. The measurement methods on the model of the ISIS reactor and on the loop in the OSIRIS reactor are described. Part two deals with the possibility of calculating the powers dissipated by each rod of the fuel cluster, using appropriate computer codes, not only in the reflector but also in the core and to suggest a method of calculation [fr

  13. Peripheral Developing Odontoma or Peripheral Ameloblastic Fibroodontoma: A Rare Challenging Case

    Directory of Open Access Journals (Sweden)

    Saede Atarbashi Moghadam

    2016-01-01

    Full Text Available Peripheral odontogenic lesions are considered to be rare within the classification of odontogenic tumors. They share the same microscopic characteristics of their central counterparts. Here, we report an ulcerated mass of the maxillary gingiva that on histopathological examination was diagnosed as peripheral developing odontoma or peripheral ameloblastic fibroodontoma. The diagnosis of this tumor is challenging and may lead to unnecessary treatment.

  14. Promising effects of xanthine oxidase inhibition by allopurinol on autonomic heart regulation estimated by heart rate variability (HRV) analysis in rats exposed to hypoxia and hyperoxia

    Science.gov (United States)

    Ziółkowski, Wiesław; Badtke, Piotr; Zajączkowski, Miłosz A.; Flis, Damian J.; Figarski, Adam; Smolińska-Bylańska, Maria; Wierzba, Tomasz H.

    2018-01-01

    Background It has long been suggested that reactive oxygen species (ROS) play a role in oxygen sensing via peripheral chemoreceptors, which would imply their involvement in chemoreflex activation and autonomic regulation of heart rate. We hypothesize that antioxidant affect neurogenic cardiovascular regulation through activation of chemoreflex which results in increased control of sympathetic mechanism regulating heart rhythm. Activity of xanthine oxidase (XO), which is among the major endogenous sources of ROS in the rat has been shown to increase during hypoxia promote oxidative stress. However, the mechanism of how XO inhibition affects neurogenic regulation of heart rhythm is still unclear. Aim The study aimed to evaluate effects of allopurinol-driven inhibition of XO on autonomic heart regulation in rats exposed to hypoxia followed by hyperoxia, using heart rate variability (HRV) analysis. Material and methods 16 conscious male Wistar rats (350 g): control-untreated (N = 8) and pretreated with Allopurinol-XO inhibitor (5 mg/kg, followed by 50 mg/kg), administered intraperitoneally (N = 8), were exposed to controlled hypobaric hypoxia (1h) in order to activate chemoreflex. The treatment was followed by 1h hyperoxia (chemoreflex suppression). Time-series of 1024 RR-intervals were extracted from 4kHz ECG recording for heart rate variability (HRV) analysis in order to calculate the following time-domain parameters: mean RR interval (RRi), SDNN (standard deviation of all normal NN intervals), rMSSD (square root of the mean of the squares of differences between adjacent NN intervals), frequency-domain parameters (FFT method): TSP (total spectral power) as well as low and high frequency band powers (LF and HF). At the end of experiment we used rat plasma to evaluate enzymatic activity of XO and markers of oxidative stress: protein carbonyl group and 8-isoprostane concentrations. Enzymatic activity of superoxide dismutase (SOD), catalase (CAT) and glutathione

  15. Promising effects of xanthine oxidase inhibition by allopurinol on autonomic heart regulation estimated by heart rate variability (HRV analysis in rats exposed to hypoxia and hyperoxia.

    Directory of Open Access Journals (Sweden)

    Stanisław Zajączkowski

    Full Text Available It has long been suggested that reactive oxygen species (ROS play a role in oxygen sensing via peripheral chemoreceptors, which would imply their involvement in chemoreflex activation and autonomic regulation of heart rate. We hypothesize that antioxidant affect neurogenic cardiovascular regulation through activation of chemoreflex which results in increased control of sympathetic mechanism regulating heart rhythm. Activity of xanthine oxidase (XO, which is among the major endogenous sources of ROS in the rat has been shown to increase during hypoxia promote oxidative stress. However, the mechanism of how XO inhibition affects neurogenic regulation of heart rhythm is still unclear.The study aimed to evaluate effects of allopurinol-driven inhibition of XO on autonomic heart regulation in rats exposed to hypoxia followed by hyperoxia, using heart rate variability (HRV analysis.16 conscious male Wistar rats (350 g: control-untreated (N = 8 and pretreated with Allopurinol-XO inhibitor (5 mg/kg, followed by 50 mg/kg, administered intraperitoneally (N = 8, were exposed to controlled hypobaric hypoxia (1h in order to activate chemoreflex. The treatment was followed by 1h hyperoxia (chemoreflex suppression. Time-series of 1024 RR-intervals were extracted from 4kHz ECG recording for heart rate variability (HRV analysis in order to calculate the following time-domain parameters: mean RR interval (RRi, SDNN (standard deviation of all normal NN intervals, rMSSD (square root of the mean of the squares of differences between adjacent NN intervals, frequency-domain parameters (FFT method: TSP (total spectral power as well as low and high frequency band powers (LF and HF. At the end of experiment we used rat plasma to evaluate enzymatic activity of XO and markers of oxidative stress: protein carbonyl group and 8-isoprostane concentrations. Enzymatic activity of superoxide dismutase (SOD, catalase (CAT and glutathione peroxidase (GPx were measures in erythrocyte

  16. Peripheral Neuropathy and Agent Orange

    Science.gov (United States)

    ... Enter ZIP code here Enter ZIP code here Peripheral Neuropathy and Agent Orange VA presumes Veterans' early-onset ... 10 percent disabling by VA's rating regulations. About peripheral neuropathy Peripheral neuropathy is a condition of the peripheral ...

  17. Loop space representation of quantum general relativity and the group of loops

    International Nuclear Information System (INIS)

    Gambini, R.

    1991-01-01

    The action of the constraints of quantum general relativity on a general state in the loop representation is coded in terms of loop derivatives. These differential operators are related to the infinitesimal generators of the group of loops and generalize the area derivative first considered by Mandelstam. A new sector of solutions of the physical states space of nonperturbative quantum general relativity is found. (orig.)

  18. Fermions and loops on graphs: I. Loop calculus for determinants

    International Nuclear Information System (INIS)

    Chernyak, Vladimir Y; Chertkov, Michael

    2008-01-01

    This paper is the first in a series devoted to evaluation of the partition function in statistical models on graphs with loops in terms of the Berezin/fermion integrals. The paper focuses on a representation of the determinant of a square matrix in terms of a finite series, where each term corresponds to a loop on the graph. The representation is based on a fermion version of the loop calculus, previously introduced by the authors for graphical models with finite alphabets. Our construction contains two levels. First, we represent the determinant in terms of an integral over anti-commuting Grassmann variables, with some reparametrization/gauge freedom hidden in the formulation. Second, we show that a special choice of the gauge, called the BP (Bethe–Peierls or belief propagation) gauge, yields the desired loop representation. The set of gauge fixing BP conditions is equivalent to the Gaussian BP equations, discussed in the past as efficient (linear scaling) heuristics for estimating the covariance of a sparse positive matrix

  19. Vascular access in neonatology: peripherally inserted central catheter and peripheral venous catheter

    Directory of Open Access Journals (Sweden)

    Marcia Lienemann

    2014-04-01

    The objective of this paper is to present aspects of peripherally inserted central catheter and peripheral venous catheter, highlighting important points in choosing the type of access. For the passage of peripherally inserted central catheter is previously performing specific course necessary, while the primary indication occurs when it is necessary to access the patient's stay for a long period of time. Whereas peripheral venipuncture is the most appropriate in cases of needing an IV line quickly and safely, for the administration of fluids, blood collection, blood transfusion and other.

  20. Dechanneling by dislocation loops

    International Nuclear Information System (INIS)

    Chalant, Gerard.

    1976-09-01

    Ion implantation always induces the creation of dislocation loops. When the damage profile is determined by a backscattering technique, the dechanneling by these loops is implicitely at the origin of these measurements. The dechanneling of alpha particles by dislocation loops produced by the coalescence of quenched-in vacancies in aluminium is studied. The dechanneling and the concentration of loops were determined simultaneously. The dechanneling width around dislocation was found equal to lambda=6A, both for perfect and imperfect loops having a mean diameter d=250A. In the latter case, a dechanneling probability chi=0.34 was determined for the stacking fault, in good agreement with previous determination in gold. A general formula is proposed which takes into account the variation of lambda with the curvature (or the diameter d) of the loops. Finally, by a series of isothermal anneals, the self-diffusion energy ΔH of aluminium was measured. The value obtained ΔH=1.32+-0.10eV is in good agreement with the values obtained by other methods [fr

  1. The Brownian loop soup

    OpenAIRE

    Lawler, Gregory F.; Werner, Wendelin

    2003-01-01

    We define a natural conformally invariant measure on unrooted Brownian loops in the plane and study some of its properties. We relate this measure to a measure on loops rooted at a boundary point of a domain and show how this relation gives a way to ``chronologically add Brownian loops'' to simple curves in the plane.

  2. Reactor recirculation pump test loop

    International Nuclear Information System (INIS)

    Taka, Shusei; Kato, Hiroyuki

    1979-01-01

    A test loop for a reactor primary loop recirculation pumps (PLR pumps) has been constructed at Ebara's Haneda Plant in preparation for production of PLR pumps under license from Byron Jackson Pump Division of Borg-Warner Corporation. This loop can simulate operating conditions for test PLR pumps with 130 per cent of the capacity of pumps for a 1100 MWe BWR plant. A main loop, primary cooling system, water demineralizer, secondary cooling system, instrumentation and control equipment and an electric power supply system make up the test loop. This article describes the test loop itself and test results of two PLR pumps for Fukushima No. 2 N.P.S. Unit 1 and one main circulation pump for HAZ Demonstration Test Facility. (author)

  3. Wilson loops in minimal surfaces

    International Nuclear Information System (INIS)

    Drukker, Nadav; Gross, David J.; Ooguri, Hirosi

    1999-01-01

    The AdS/CFT correspondence suggests that the Wilson loop of the large N gauge theory with N = 4 supersymmetry in 4 dimensions is described by a minimal surface in AdS 5 x S 5 . The authors examine various aspects of this proposal, comparing gauge theory expectations with computations of minimal surfaces. There is a distinguished class of loops, which the authors call BPS loops, whose expectation values are free from ultra-violet divergence. They formulate the loop equation for such loops. To the extent that they have checked, the minimal surface in AdS 5 x S 5 gives a solution of the equation. The authors also discuss the zig-zag symmetry of the loop operator. In the N = 4 gauge theory, they expect the zig-zag symmetry to hold when the loop does not couple the scalar fields in the supermultiplet. They will show how this is realized for the minimal surface

  4. Wilson loops and minimal surfaces

    International Nuclear Information System (INIS)

    Drukker, Nadav; Gross, David J.; Ooguri, Hirosi

    1999-01-01

    The AdS-CFT correspondence suggests that the Wilson loop of the large N gauge theory with N=4 supersymmetry in four dimensions is described by a minimal surface in AdS 5 xS 5 . We examine various aspects of this proposal, comparing gauge theory expectations with computations of minimal surfaces. There is a distinguished class of loops, which we call BPS loops, whose expectation values are free from ultraviolet divergence. We formulate the loop equation for such loops. To the extent that we have checked, the minimal surface in AdS 5 xS 5 gives a solution of the equation. We also discuss the zigzag symmetry of the loop operator. In the N=4 gauge theory, we expect the zigzag symmetry to hold when the loop does not couple the scalar fields in the supermultiplet. We will show how this is realized for the minimal surface. (c) 1999 The American Physical Society

  5. A role for myelin-associated peroxisomes in maintaining paranodal loops and axonal integrity.

    Science.gov (United States)

    Kassmann, Celia M; Quintes, Susanne; Rietdorf, Jens; Möbius, Wiebke; Sereda, Michael Werner; Nientiedt, Tobias; Saher, Gesine; Baes, Myriam; Nave, Klaus-Armin

    2011-07-21

    Demyelinating diseases of the nervous system cause axon loss but the underlying mechanisms are not well understood. Here we show by confocal and electron microscopy that in myelin-forming glia peroxisomes are associated with myelin membranes. When peroxisome biogenesis is experimentally perturbed in Pex5 conditional mouse mutants, myelination by Schwann cells appears initially normal. However, in nerves of older mice paranodal loops become physically unstable and develop swellings filled with vesicles and electron-dense material. This novel model of a demyelinating neuropathy demonstrates that peroxisomes serve an important function in the peripheral myelin compartment, required for long-term axonal integrity. Copyright © 2011 Federation of European Biochemical Societies. Published by Elsevier B.V. All rights reserved.

  6. BPS Wilson loops and Bremsstrahlung function in ABJ(M): a two loop analysis

    Energy Technology Data Exchange (ETDEWEB)

    Bianchi, Marco S. [Institut für Physik, Humboldt-Universität zu Berlin,Newtonstraße 15, 12489 Berlin (Germany); Griguolo, Luca [Dipartimento di Fisica e Scienze della Terra, Università di Parmaand INFN Gruppo Collegato di Parma,Viale G.P. Usberti 7/A, 43100 Parma (Italy); Leoni, Matias [Physics Department, FCEyN-UBA & IFIBA-CONICETCiudad Universitaria, Pabellón I, 1428, Buenos Aires (Argentina); Penati, Silvia [Dipartimento di Fisica, Università di Milano-Bicoccaand INFN, Sezione di Milano-Bicocca,Piazza della Scienza 3, I-20126 Milano (Italy); Seminara, Domenico [Dipartimento di Fisica, Università di Firenzeand INFN Sezione di Firenze,via G. Sansone 1, 50019 Sesto Fiorentino (Italy)

    2014-06-19

    We study a family of circular BPS Wilson loops in N=6 super Chern-Simons-matter theories, generalizing the usual 1/2-BPS circle. The scalar and fermionic couplings depend on two deformation parameters and these operators can be considered as the ABJ(M) counterpart of the DGRT latitudes defined in N=4 SYM. We perform a complete two-loop analysis of their vacuum expectation value, discuss the appearance of framing-like phases and propose a general relation with cohomologically equivalent bosonic operators. We make an all-loop proposal for computing the Bremsstrahlung function associated to the 1/2-BPS cusp in terms of these generalized Wilson loops. When applied to our two-loop result it reproduces the known expression. Finally, we comment on the generalization of this proposal to the bosonic 1/6-BPS case.

  7. Weighing black holes using open-loop focus corrections for LGS-AO observations of galaxy nuclei at Gemini Observatory

    Science.gov (United States)

    McDermid, Richard M.; Krajnovic, Davor; Cappellari, Michele; Trujillo, Chadwick; Christou, Julian; Davies, Roger L.

    2010-07-01

    We present observations of early-type galaxies with laser guide star adaptive optics (LGS AO) obtained at Gemini North telescope using the NIFS integral field unit (IFU). We employ an innovative technique where the focus compensation due to the changing distance to the sodium layer is made 'open loop', allowing the extended galaxy nucleus to be used only for tip-tilt correction. The purpose of these observations is to determine high spatial resolution stellar kinematics within the nuclei of these galaxies to determine the masses of the super-massive black holes. The resulting data have spatial resolution of 0.2" FWHM or better. This is sufficient to positively constrain the presence of the central black hole in even low-mass early-type galaxies, suggesting that larger samples of such objects could be observed with this technique in the future. The open-loop focus correction technique is a supported queue-observing mode at Gemini, significantly extending the sky coverage in particular for faint, extended guide sources. We also provide preliminary results from tests combining tip/tilt correction from the Gemini peripheral guider with on-axis LGS. The current test system demonstrates feasibility of this mode, providing about a factor 2-3 improvement over natural seeing. With planned upgrades to the peripheral wave-front sensor, we hope to provide close to 100% sky coverage with low Strehl corrections, or 'improved seeing', significantly increasing flux concentration for deep field and extended object studies.

  8. Drug-induced peripheral neuropathy

    DEFF Research Database (Denmark)

    Vilholm, Ole Jakob; Christensen, Alex Alban; Zedan, Ahmed

    2014-01-01

    Peripheral neuropathy can be caused by medication, and various descriptions have been applied for this condition. In this MiniReview, the term 'drug-induced peripheral neuropathy' (DIPN) is used with the suggested definition: Damage to nerves of the peripheral nervous system caused by a chemical...... substance used in the treatment, cure, prevention or diagnosis of a disease. Optic neuropathy is included in this definition. A distinction between DIPN and other aetiologies of peripheral neuropathy is often quite difficult and thus, the aim of this MiniReview is to discuss the major agents associated...

  9. Computational stability appraisal of rectangular natural circulation loop: Effect of loop inclination

    International Nuclear Information System (INIS)

    Krishnani, Mayur; Basu, Dipankar N.

    2017-01-01

    Highlights: • Computational model developed for single-phase rectangular natural circulation loop. • Role of loop inclination to vertical on thermalhydraulic stability is explored. • Inclination has strong stabilizing effect due to lower effective gravitation force. • Increase in tilt angle reduces settling time and highest amplitude of oscillation. • An angle of 15° is suggested for the selected loop geometry. - Abstract: Controlling stability behavior of single-phase natural circulation loops, without significantly affecting its steady-state characteristics, is a topic of wide research interest. Present study explores the role of loop inclination on a particular loop geometry. Accordingly a 3D computational model of a rectangular loop is developed and transient conservation equations are solved to obtain the temporal variation in flow parameters. Starting from the quiescent state, simulations are performed for selected sets of operating conditions and also with a few selected inclination angles. System experiences instability at higher heater powers and also with higher sink temperatures. Inclination is found to have a strong stabilizing influence owing to the reduction in the effective gravitational acceleration and subsequent decline in local buoyancy effects. The settling time and highest amplitude of oscillations substantially reduces for a stable system with a small inclination. Typically-unstable systems can also suppress the oscillations, when subjected to tilting, within a reasonable period of time. It is possible to stabilize the loop within shorter time span by increasing the tilt angle, but at the expense of reduction in steady-state flow rate. Overall a tilt angle of 15° is suggested for the selected geometry. Results from the 3D model is compared with the predictions from an indigenous 1D code. While similar qualitative influence of inclination is observed, the 1D model predicts early appearance of the stability threshold and hence hints

  10. Diffusion of Wilson loops

    International Nuclear Information System (INIS)

    Brzoska, A.M.; Lenz, F.; Thies, M.; Negele, J.W.

    2005-01-01

    A phenomenological analysis of the distribution of Wilson loops in SU(2) Yang-Mills theory is presented in which Wilson loop distributions are described as the result of a diffusion process on the group manifold. It is shown that, in the absence of forces, diffusion implies Casimir scaling and, conversely, exact Casimir scaling implies free diffusion. Screening processes occur if diffusion takes place in a potential. The crucial distinction between screening of fundamental and adjoint loops is formulated as a symmetry property related to the center symmetry of the underlying gauge theory. The results are expressed in terms of an effective Wilson loop action and compared with various limits of SU(2) Yang-Mills theory

  11. On some properties of conjugacy closed loops

    International Nuclear Information System (INIS)

    Adeniran, John Olusola

    2002-07-01

    It is shown that central loops are not conjugacy closed loops but instead are loops of units in their loop algebras that are conjugacy closed. It is also shown that certain inner mappings of a conjugacy closed loop are nuclear. Some invariants of left conjugacy closed loops are obtained. (author)

  12. Mirror symmetry and loop operators

    Energy Technology Data Exchange (ETDEWEB)

    Assel, Benjamin [Department of Mathematics, King’s College London,The Strand, London WC2R 2LS (United Kingdom); Gomis, Jaume [Perimeter Institute for Theoretical Physics,Waterloo, Ontario, N2L 2Y5 (Canada)

    2015-11-09

    Wilson loops in gauge theories pose a fundamental challenge for dualities. Wilson loops are labeled by a representation of the gauge group and should map under duality to loop operators labeled by the same data, yet generically, dual theories have completely different gauge groups. In this paper we resolve this conundrum for three dimensional mirror symmetry. We show that Wilson loops are exchanged under mirror symmetry with Vortex loop operators, whose microscopic definition in terms of a supersymmetric quantum mechanics coupled to the theory encode in a non-trivial way a representation of the original gauge group, despite that the gauge groups of mirror theories can be radically different. Our predictions for the mirror map, which we derive guided by branes in string theory, are confirmed by the computation of the exact expectation value of Wilson and Vortex loop operators on the three-sphere.

  13. WWER type reactor primary loop imitation on large test loop facility in MARIA reactor

    International Nuclear Information System (INIS)

    Moldysh, A.; Strupchevski, A.; Kmetek, Eh.; Spasskov, V.P.; Shumskij, A.M.

    1982-01-01

    At present in Poland in cooperation with USSR a nuclear water loop test facility (WL) in 'MARIA' reactor in Sverke is under construction. The program objective is to investigate processes occuring in WWER reactor under emergency conditions, first of all after the break of the mainprimary loop circulation pipe-line. WL with the power of about 600 kW consists of three major parts: 1) an active loop, imitating the undamaged loops of the WWER reactor; 2) a passive loop assignedfor modelling the broken loop of the WWER reactor; 3) the emergency core cooling system imitating the corresponding full-scale system. The fuel rod bundle consists of 18 1 m long rods. They were fabricated according to the standard WWER fuel technology. In the report some general principles of WWERbehaviour imitation under emergency conditions are given. They are based on the operation experience obtained from 'SEMISCALE' and 'LOFT' test facilities in the USA. A description of separate modelling factors and criteria effects on the development of 'LOCA'-type accident is presented (the break cross-section to the primary loop volume ratio, the pressure differential between inlet and outlet reactor chambers, the pressure drop rate in the loop, the coolant flow rate throuh the core etc.). As an example a comparison of calculated flow rate variations for the WWER-1000 reactor and the model during the loss-of-coolant accident with the main pipe-line break at the core inlet is given. Calculations have been carried out with the use of TECH'-M code [ru

  14. Natively unstructured loops differ from other loops.

    Directory of Open Access Journals (Sweden)

    Avner Schlessinger

    2007-07-01

    Full Text Available Natively unstructured or disordered protein regions may increase the functional complexity of an organism; they are particularly abundant in eukaryotes and often evade structure determination. Many computational methods predict unstructured regions by training on outliers in otherwise well-ordered structures. Here, we introduce an approach that uses a neural network in a very different and novel way. We hypothesize that very long contiguous segments with nonregular secondary structure (NORS regions differ significantly from regular, well-structured loops, and that a method detecting such features could predict natively unstructured regions. Training our new method, NORSnet, on predicted information rather than on experimental data yielded three major advantages: it removed the overlap between testing and training, it systematically covered entire proteomes, and it explicitly focused on one particular aspect of unstructured regions with a simple structural interpretation, namely that they are loops. Our hypothesis was correct: well-structured and unstructured loops differ so substantially that NORSnet succeeded in their distinction. Benchmarks on previously used and new experimental data of unstructured regions revealed that NORSnet performed very well. Although it was not the best single prediction method, NORSnet was sufficiently accurate to flag unstructured regions in proteins that were previously not annotated. In one application, NORSnet revealed previously undetected unstructured regions in putative targets for structural genomics and may thereby contribute to increasing structural coverage of large eukaryotic families. NORSnet found unstructured regions more often in domain boundaries than expected at random. In another application, we estimated that 50%-70% of all worm proteins observed to have more than seven protein-protein interaction partners have unstructured regions. The comparative analysis between NORSnet and DISOPRED2 suggested

  15. A type of loop algebra and the associated loop algebras

    International Nuclear Information System (INIS)

    Tam Honwah; Zhang Yufeng

    2008-01-01

    A higher-dimensional twisted loop algebra is constructed. As its application, a new Lax pair is presented, whose compatibility gives rise to a Liouville integrable hierarchy of evolution equations by making use of Tu scheme. One of the reduction cases of the hierarchy is an analogous of the well-known AKNS system. Next, the twisted loop algebra, furthermore, is extended to another higher dimensional loop algebra, from which a hierarchy of evolution equations with 11-potential component functions is obtained, whose reduction is just standard AKNS system. Especially, we prove that an arbitrary linear combination of the four Hamiltonian operators directly obtained from the recurrence relations is still a Hamiltonian operator. Therefore, the hierarchy with 11-potential functions possesses 4-Hamiltonian structures. Finally, an integrable coupling of the hierarchy is worked out

  16. Propylthiouracil and peripheral neuropathy

    Directory of Open Access Journals (Sweden)

    Valentina Van Boekel

    1992-06-01

    Full Text Available Peripheral neuropathy is a rare manifestation in hyperthyroidism. We describe the neurological manifestations of a 38 year old female with Graves' disease who developed peripheral neuropathy in the course of her treatment with propylthiouracil. After the drug was tapered off, the neurological signs disappeared. Therefore, we call attention for a possible toxic effect on peripheral nervous system caused by this drug.

  17. Interaction between 99Tcm-hydroxmethylene diphosphonate and loop-diuretics in an experimental mouse system

    International Nuclear Information System (INIS)

    Cronhjort, M.; Sjoeberg, H.E.; Schnell, P.O.; Jacobsson, H.

    1994-01-01

    The image quality at bone scintigraphy depends largely on the bone/soft-tissue activity ratio. This varies considerably between different patients and may sometimes be strongly reduced. The ratio increases with time due to urinary excretion of extracelluar activity. The possibility to utilize the phosphaturic effect of loop-diuretics to enhance the excretion of the soft tissue activity caused by radiolabeled phosphonate compounds at bone scintigraphy has been studied. Three loop-diuretics (Bumetanide, Ethacrynic acid and Furosemide) were injected at different times in relation to 99 Tc m -Hydroxymethylene diphosphonate (HDP) in mice. By assessing the activity of different organs as well as of peripheral blood by a gamma-counter, the activity distribution in the animals was established. Administration of diuretics together with, or after HDP has a negative influence on the quality of the potential HDP-image. Administration of diuretics prior to the radiopharmaceutical slightly improves the image quality, but not to an extent justifying it use for this purpose in practice. The complex effects on HDP may be explained by the influence of Furosemide on calcium, pH and on blood plasma volume and their hormonal consequences. (orig.) [de

  18. Peripheral Neuropathy: Symptoms and Signs

    Science.gov (United States)

    ... Utah Research News Make a Difference Symptoms of Peripheral Neuropathy Print This Page Peripheral Neuropathy symptoms usually start ... more slowly over many years. The symptoms of peripheral neuropathy often include: A sensation of wearing an invisible “ ...

  19. Modeling of compact loop antennas

    International Nuclear Information System (INIS)

    Baity, F.W.

    1987-01-01

    A general compact loop antenna model which treats all elements of the antenna as lossy transmission lines has been developed. In addition to capacitively-tuned resonant double loop (RDL) antennas the model treats stub-tuned resonant double loop antennas. Calculations using the model have been compared with measurements on full-scale mockups of resonant double loop antennas for ATF and TFTR in order to refine the transmission line parameters. Results from the model are presented for RDL antenna designs for ATF, TFTR, Tore Supra, and for the Compact Ignition Tokamak

  20. Rogowski Loop design for NSTX

    International Nuclear Information System (INIS)

    McCormack, B.; Kaita, R.; Kugel, H.; Hatcher, R.

    2000-01-01

    The Rogowski Loop is one of the most basic diagnostics for tokamak operations. On the National Spherical Torus Experiment (NSTX), the plasma current Rogowski Loop had the constraints of the very limited space available on the center stack, 5,000 volt isolation, flexibility requirements as it remained a part of the Center Stack assembly after the first phase of operation, and a +120 C temperature requirement. For the second phase of operation, four Halo Current Rogowski Loops under the Center Stack tiles will be installed having +600 C and limited space requirements. Also as part of the second operational phase, up to ten Rogowski Loops will installed to measure eddy currents in the Passive Plate support structures with +350 C, restricted space, and flexibility requirements. This presentation will provide the details of the material selection, fabrication techniques, testing, and installation results of the Rogowski Loops that were fabricated for the high temperature operational and bakeout requirements, high voltage isolation requirements, and the space and flexibility requirements imposed upon the Rogowski Loops. In the future operational phases of NSTX, additional Rogowski Loops could be anticipated that will measure toroidal plasma currents in the vacuum vessel and in the Passive Plate assemblies

  1. Donating Peripheral Blood Stem Cells

    Science.gov (United States)

    ... Print this page My Cart Donating peripheral blood stem cells Peripheral blood stem cell (PBSC) donation is a nonsurgical procedure to collect ... Donating bone marrow Donor experiences videos Peripheral blood stem cell (PBSC) donation is one of two methods of ...

  2. Hybrid Combustion-Gasification Chemical Looping

    Energy Technology Data Exchange (ETDEWEB)

    Herbert Andrus; Gregory Burns; John Chiu; Gregory Lijedahl; Peter Stromberg; Paul Thibeault

    2009-01-07

    For the past several years Alstom Power Inc. (Alstom), a leading world-wide power system manufacturer and supplier, has been in the initial stages of developing an entirely new, ultra-clean, low cost, high efficiency power plant for the global power market. This new power plant concept is based on a hybrid combustion-gasification process utilizing high temperature chemical and thermal looping technology The process consists of the oxidation, reduction, carbonation, and calcination of calcium-based compounds, which chemically react with coal, biomass, or opportunity fuels in two chemical loops and one thermal loop. The chemical and thermal looping technology can be alternatively configured as (i) a combustion-based steam power plant with CO{sub 2} capture, (ii) a hybrid combustion-gasification process producing a syngas for gas turbines or fuel cells, or (iii) an integrated hybrid combustion-gasification process producing hydrogen for gas turbines, fuel cells or other hydrogen based applications while also producing a separate stream of CO{sub 2} for use or sequestration. In its most advanced configuration, this new concept offers the promise to become the technology link from today's Rankine cycle steam power plants to tomorrow's advanced energy plants. The objective of this work is to develop and verify the high temperature chemical and thermal looping process concept at a small-scale pilot facility in order to enable AL to design, construct and demonstrate a pre-commercial, prototype version of this advanced system. In support of this objective, Alstom and DOE started a multi-year program, under this contract. Before the contract started, in a preliminary phase (Phase 0) Alstom funded and built the required small-scale pilot facility (Process Development Unit, PDU) at its Power Plant Laboratories in Windsor, Connecticut. Construction was completed in calendar year 2003. The objective for Phase I was to develop the indirect combustion loop with CO{sub 2

  3. Thermal-hydraulic analyses for in-pile SCWR fuel qualification test loops and SCWR material loop

    Energy Technology Data Exchange (ETDEWEB)

    Vojacek, A.; Mazzini, G.; Zmitkova, J.; Ruzickova, M. [Research Centre Rez (Czech Republic)

    2014-07-01

    One of the R&D directions of Research Centre Rez is dedicated to the supercritical water-cooled reactor concept (SCWR). Among the developed experimental facilities and infrastructure in the framework of the SUSEN project (SUStainable ENergy) is construction and experimental operation of the supercritical water loop SCWL focusing on material tests. At the first phase, this SCWL loop is assembled and operated out-of-pile in the dedicated loop facilities hall. At this out-of-pile operation various operational conditions are tested and verified. After that, in the second phase, the SCWL loop will be situated in-pile, in the core of the research reactor LVR-15, operated at CVR. Furthermore, it is planned to carry out a test of a small scale fuel assembly within the SuperCritical Water Reactor Fuel Qualification Test (SCWR-FQT) loop, which is now being designed. This paper presents the results of the thermal-hydraulic analyses of SCWL loop out-of-pile operation using the RELAP5/MOD3.3. The thermal-hydraulic modeling and the performed analyses are focused on the SCWL loop model validation through a comparison of the calculation results with the experimental results obtained at various operation conditions. Further, the present paper focuses on the transient analyses for start-up and shut-down of the FQT loop, particularly to explore the ability of system codes ATHLET 3.0A to simulate the transient between subcritical conditions and supercritical conditions. (author)

  4. Algorithm for counting large directed loops

    Energy Technology Data Exchange (ETDEWEB)

    Bianconi, Ginestra [Abdus Salam International Center for Theoretical Physics, Strada Costiera 11, 34014 Trieste (Italy); Gulbahce, Natali [Theoretical Division and Center for Nonlinear Studies, Los Alamos National Laboratory, NM 87545 (United States)

    2008-06-06

    We derive a Belief-Propagation algorithm for counting large loops in a directed network. We evaluate the distribution of the number of small loops in a directed random network with given degree sequence. We apply the algorithm to a few characteristic directed networks of various network sizes and loop structures and compare the algorithm with exhaustive counting results when possible. The algorithm is adequate in estimating loop counts for large directed networks and can be used to compare the loop structure of directed networks and their randomized counterparts.

  5. Oscillation damping of chiral string loops

    International Nuclear Information System (INIS)

    Babichev, Eugeny; Dokuchaev, Vyacheslav

    2002-01-01

    Chiral cosmic string loops tend to the stationary (vorton) configuration due to energy loss into gravitational and electromagnetic radiation. We describe the asymptotic behavior of near stationary chiral loops and their fading to vortons. General limits on the gravitational and electromagnetic energy losses by near stationary chiral loops are found. For these loops we estimate the oscillation damping time. We present solvable examples of gravitational radiation energy loss by some chiral loop configurations. The analytical dependence of string energy with time is found in the case of the chiral ring with small amplitude radial oscillations

  6. LoopX: A Graphical User Interface-Based Database for Comprehensive Analysis and Comparative Evaluation of Loops from Protein Structures.

    Science.gov (United States)

    Kadumuri, Rajashekar Varma; Vadrevu, Ramakrishna

    2017-10-01

    Due to their crucial role in function, folding, and stability, protein loops are being targeted for grafting/designing to create novel or alter existing functionality and improve stability and foldability. With a view to facilitate a thorough analysis and effectual search options for extracting and comparing loops for sequence and structural compatibility, we developed, LoopX a comprehensively compiled library of sequence and conformational features of ∼700,000 loops from protein structures. The database equipped with a graphical user interface is empowered with diverse query tools and search algorithms, with various rendering options to visualize the sequence- and structural-level information along with hydrogen bonding patterns, backbone φ, ψ dihedral angles of both the target and candidate loops. Two new features (i) conservation of the polar/nonpolar environment and (ii) conservation of sequence and conformation of specific residues within the loops have also been incorporated in the search and retrieval of compatible loops for a chosen target loop. Thus, the LoopX server not only serves as a database and visualization tool for sequence and structural analysis of protein loops but also aids in extracting and comparing candidate loops for a given target loop based on user-defined search options.

  7. Tumors of peripheral nerves

    International Nuclear Information System (INIS)

    Ho, Michael; Lutz, Amelie M.

    2017-01-01

    Differentiation between malignant and benign tumors of peripheral nerves in the early stages is challenging; however, due to the unfavorable prognosis of malignant tumors early identification is required. To show the possibilities for detection, differential diagnosis and clinical management of peripheral nerve tumors by imaging appearance in magnetic resonance (MR) neurography. Review of current literature available in PubMed and MEDLINE, supplemented by the authors' own observations in clinical practice. Although not pathognomonic, several imaging features have been reported for a differentiation between distinct peripheral nerve tumors. The use of MR neurography enables detection and initial differential diagnosis in tumors of peripheral nerves. Furthermore, it plays an important role in clinical follow-up, targeted biopsy and surgical planning. (orig.) [de

  8. On the loop-loop scattering amplitudes in Abelian and non-Abelian gauge theories

    International Nuclear Information System (INIS)

    Meggiolaro, Enrico

    2005-01-01

    The high-energy elastic scattering amplitude of two colour-singlet qq-bar pairs is governed by the correlation function of two Wilson loops, which follow the classical straight lines for quark (antiquark) trajectories. This quantity is expected to be free of IR divergences, differently from what happens for the parton-parton elastic scattering amplitude, described, in the high-energy limit, by the expectation value of two Wilson lines. We shall explicitly test this IR finiteness by a direct non-perturbative computation of the loop-loop scattering amplitudes in the (pedagogic, but surely physically interesting) case of quenched QED. The results obtained for the Abelian case will be generalized to the case of a non-Abelian gauge theory with Nc colours, but stopping to the order O(g4) in perturbation theory. In connection with the above-mentioned IR finiteness, we shall also discuss some analytic properties of the loop-loop scattering amplitudes in both Abelian and non-Abelian gauge theories, when going from Minkowskian to Euclidean theory, which can be relevant to the still unsolved problem of the s-dependence of hadron-hadron total cross-sections

  9. Peripheral dentinogenic ghost cell tumor

    Directory of Open Access Journals (Sweden)

    Sushant S Kamat

    2013-01-01

    Full Text Available Dentinogenic ghost cell tumors (DGCT are uncommon lesions mainly with rare peripheral types. This report presents a case of peripheral DGCT on the left side of the mandibular alveolar ridge of a heavy smoker, a 68-year-old man, with main presenting feature as a mild pain. Submandibular lymphadenopathy and radiological "saucerization" were evident. Differential diagnosis included fibroma, neurofibroma, peripheral ameloblastoma, peripheral odontogenic fibroma, and peripheral giant cell granuloma. Histologically, ameloblastoma-like epithelial elements were seen in association with grouped ghost cells. Proliferating polyhedral cells and stellate reticulum-like cells with various densities were spread over a wide range of the field. The lesion was curetted and after 2 years of follow up, it did not recur.

  10. Higher dimensional loop quantum cosmology

    International Nuclear Information System (INIS)

    Zhang, Xiangdong

    2016-01-01

    Loop quantum cosmology (LQC) is the symmetric sector of loop quantum gravity. In this paper, we generalize the structure of loop quantum cosmology to the theories with arbitrary spacetime dimensions. The isotropic and homogeneous cosmological model in n + 1 dimensions is quantized by the loop quantization method. Interestingly, we find that the underlying quantum theories are divided into two qualitatively different sectors according to spacetime dimensions. The effective Hamiltonian and modified dynamical equations of n + 1 dimensional LQC are obtained. Moreover, our results indicate that the classical big bang singularity is resolved in arbitrary spacetime dimensions by a quantum bounce. We also briefly discuss the similarities and differences between the n + 1 dimensional model and the 3 + 1 dimensional one. Our model serves as a first example of higher dimensional loop quantum cosmology and offers the possibility to investigate quantum gravity effects in higher dimensional cosmology. (orig.)

  11. Hyperstaticity and loops in frictional granular packings

    Science.gov (United States)

    Tordesillas, Antoinette; Lam, Edward; Metzger, Philip T.

    2009-06-01

    The hyperstatic nature of granular packings of perfectly rigid disks is analyzed algebraically and through numerical simulation. The elementary loops of grains emerge as a fundamental element in addressing hyperstaticity. Loops consisting of an odd number of grains behave differently than those with an even number. For odd loops, the latent stresses are exterior and are characterized by the sum of frictional forces around each loop. For even loops, the latent stresses are interior and are characterized by the alternating sum of frictional forces around each loop. The statistics of these two types of loop sums are found to be Gibbsian with a "temperature" that is linear with the friction coefficient μ when μ<1.

  12. Loop Heat Pipe Startup Behaviors

    Science.gov (United States)

    Ku, Jentung

    2016-01-01

    A loop heat pipe must start successfully before it can commence its service. The startup transient represents one of the most complex phenomena in the loop heat pipe operation. This paper discusses various aspects of loop heat pipe startup behaviors. Topics include the four startup scenarios, the initial fluid distribution between the evaporator and reservoir that determines the startup scenario, factors that affect the fluid distribution between the evaporator and reservoir, difficulties encountered during the low power startup, and methods to enhance the startup success. Also addressed are the pressure spike and pressure surge during the startup transient, and repeated cycles of loop startup and shutdown under certain conditions.

  13. Conformal boundary loop models

    International Nuclear Information System (INIS)

    Jacobsen, Jesper Lykke; Saleur, Hubert

    2008-01-01

    We study a model of densely packed self-avoiding loops on the annulus, related to the Temperley-Lieb algebra with an extra idempotent boundary generator. Four different weights are given to the loops, depending on their homotopy class and whether they touch the outer rim of the annulus. When the weight of a contractible bulk loop x≡q+q -1 element of (-2,2], this model is conformally invariant for any real weight of the remaining three parameters. We classify the conformal boundary conditions and give exact expressions for the corresponding boundary scaling dimensions. The amplitudes with which the sectors with any prescribed number and types of non-contractible loops appear in the full partition function Z are computed rigorously. Based on this, we write a number of identities involving Z which hold true for any finite size. When the weight of a contractible boundary loop y takes certain discrete values, y r ≡([r+1] q )/([r] q ) with r integer, other identities involving the standard characters K r,s of the Virasoro algebra are established. The connection with Dirichlet and Neumann boundary conditions in the O(n) model is discussed in detail, and new scaling dimensions are derived. When q is a root of unity and y=y r , exact connections with the A m type RSOS model are made. These involve precise relations between the spectra of the loop and RSOS model transfer matrices, valid in finite size. Finally, the results where y=y r are related to the theory of Temperley-Lieb cabling

  14. Large lithium loop experience

    International Nuclear Information System (INIS)

    Kolowith, R.; Owen, T.J.; Berg, J.D.; Atwood, J.M.

    1981-10-01

    An engineering design and operating experience of a large, isothermal, lithium-coolant test loop are presented. This liquid metal coolant loop is called the Experimental Lithium System (ELS) and has operated safely and reliably for over 6500 hours through September 1981. The loop is used for full-scale testing of components for the Fusion Materials Irradiation Test (FMIT) Facility. Main system parameters include coolant temperatures to 430 0 C and flow to 0.038 m 3 /s (600 gal/min). Performance of the main pump, vacuum system, and control system is discussed. Unique test capabilities of the ELS are also discussed

  15. Beauty and cuteness in peripheral vision

    Science.gov (United States)

    Kuraguchi, Kana; Ashida, Hiroshi

    2015-01-01

    Guo et al. (2011) showed that attractiveness was detectable in peripheral vision. Since there are different types of attractiveness (Rhodes, 2006), we investigated how beauty and cuteness are detected in peripheral vision with a brief presentation. Participants (n = 45) observed two Japanese female faces for 100 ms, then were asked to respond which face was more beautiful (or cuter). The results indicated that both beauty and cuteness were detectable in peripheral vision, but not in the same manner. Discrimination rates for judging beauty were invariant in peripheral and central vision, while discrimination rates for judging cuteness declined in peripheral vision as compared with central vision. This was not explained by lower resolution in peripheral vision. In addition, for male participants, it was more difficult to judge cuteness than beauty in peripheral vision, thus suggesting that gender differences can have a certain effect when judging cuteness. Therefore, central vision might be suitable for judging cuteness while judging beauty might not be affected by either central or peripheral vision. This might be related with the functional difference between beauty and cuteness. PMID:25999883

  16. Modular invariance and covariant loop calculus

    International Nuclear Information System (INIS)

    Petersen, J.L.; Roland, K.O.; Sidenius, J.R.

    1988-01-01

    The covariant loop calculus provides an efficient technique for computing explicit expressions for the density on moduli space corresponding to arbitrary (bosonic string) loop diagrams. Since modular invariance is not manifest, however, we carry out a detailed comparison with known explicit two- and three-loop results derived using analytic geometry (one loop is known to be okay). We establish identity to 'high' order in some moduli and exactly in others. Agreement is found as a result of various nontrivial cancellations, in part related to number theory. We feel our results provide very strong support for the correctness of the covariant loop calculus approach. (orig.)

  17. Modular invariance and covariant loop calculus

    International Nuclear Information System (INIS)

    Petersen, J.L.; Roland, K.O.; Sidenius, J.R.

    1988-01-01

    The covariant loop calculus provides and efficient technique for computing explicit expressions for the density on moduli space corresponding to arbitrary (bosonic string) loop diagrams. Since modular invariance is not manifest, however, we carry out a detailed comparison with known explicit 2- and 3- loop results derived using analytic geometry (1 loop is known to be ok). We establish identity to 'high' order in some moduli and exactly in others. Agreement is found as a result of various non-trivial cancellations, in part related to number theory. We feel our results provide very strong support for the correctness of the covariant loop calculus approach. (orig.)

  18. Parallel tiled Nussinov RNA folding loop nest generated using both dependence graph transitive closure and loop skewing.

    Science.gov (United States)

    Palkowski, Marek; Bielecki, Wlodzimierz

    2017-06-02

    RNA secondary structure prediction is a compute intensive task that lies at the core of several search algorithms in bioinformatics. Fortunately, the RNA folding approaches, such as the Nussinov base pair maximization, involve mathematical operations over affine control loops whose iteration space can be represented by the polyhedral model. Polyhedral compilation techniques have proven to be a powerful tool for optimization of dense array codes. However, classical affine loop nest transformations used with these techniques do not optimize effectively codes of dynamic programming of RNA structure predictions. The purpose of this paper is to present a novel approach allowing for generation of a parallel tiled Nussinov RNA loop nest exposing significantly higher performance than that of known related code. This effect is achieved due to improving code locality and calculation parallelization. In order to improve code locality, we apply our previously published technique of automatic loop nest tiling to all the three loops of the Nussinov loop nest. This approach first forms original rectangular 3D tiles and then corrects them to establish their validity by means of applying the transitive closure of a dependence graph. To produce parallel code, we apply the loop skewing technique to a tiled Nussinov loop nest. The technique is implemented as a part of the publicly available polyhedral source-to-source TRACO compiler. Generated code was run on modern Intel multi-core processors and coprocessors. We present the speed-up factor of generated Nussinov RNA parallel code and demonstrate that it is considerably faster than related codes in which only the two outer loops of the Nussinov loop nest are tiled.

  19. Gauge theory loop operators and Liouville theory

    International Nuclear Information System (INIS)

    Drukker, Nadav; Teschner, Joerg

    2009-10-01

    We propose a correspondence between loop operators in a family of four dimensional N=2 gauge theories on S 4 - including Wilson, 't Hooft and dyonic operators - and Liouville theory loop operators on a Riemann surface. This extends the beautiful relation between the partition function of these N=2 gauge theories and Liouville correlators found by Alday, Gaiotto and Tachikawa. We show that the computation of these Liouville correlators with the insertion of a Liouville loop operator reproduces Pestun's formula capturing the expectation value of a Wilson loop operator in the corresponding gauge theory. We prove that our definition of Liouville loop operators is invariant under modular transformations, which given our correspondence, implies the conjectured action of S-duality on the gauge theory loop operators. Our computations in Liouville theory make an explicit prediction for the exact expectation value of 't Hooft and dyonic loop operators in these N=2 gauge theories. The Liouville loop operators are also found to admit a simple geometric interpretation within quantum Teichmueller theory as the quantum operators representing the length of geodesics. We study the algebra of Liouville loop operators and show that it gives evidence for our proposal as well as providing definite predictions for the operator product expansion of loop operators in gauge theory. (orig.)

  20. A True Open-Loop Synchronization Technique

    DEFF Research Database (Denmark)

    Golestan, Saeed; Vidal, Ana; Yepes, Alejandro G.

    2016-01-01

    Synchronization techniques can be broadly classified into two major categories: Closed-loop and open-loop methods. The open-loop synchronization (OLS) techniques, contrary to the closed-loop ones, are unconditionally stable and benefit from a fast dynamic response. Their performance, however, tends...... is to develop a true OLS (and therefore, unconditionally stable) technique without any need for the calculation of sine and cosine functions. The effectiveness of the proposed synchronization technique is confirmed through the simulation and experimental results....

  1. A kinematic view of loop closure.

    Science.gov (United States)

    Coutsias, Evangelos A; Seok, Chaok; Jacobson, Matthew P; Dill, Ken A

    2004-03-01

    We consider the problem of loop closure, i.e., of finding the ensemble of possible backbone structures of a chain segment of a protein molecule that is geometrically consistent with preceding and following parts of the chain whose structures are given. We reduce this problem of determining the loop conformations of six torsions to finding the real roots of a 16th degree polynomial in one variable, based on the robotics literature on the kinematics of the equivalent rotator linkage in the most general case of oblique rotators. We provide a simple intuitive view and derivation of the polynomial for the case in which each of the three pair of torsional axes has a common point. Our method generalizes previous work on analytical loop closure in that the torsion angles need not be consecutive, and any rigid intervening segments are allowed between the free torsions. Our approach also allows for a small degree of flexibility in the bond angles and the peptide torsion angles; this substantially enlarges the space of solvable configurations as is demonstrated by an application of the method to the modeling of cyclic pentapeptides. We give further applications to two important problems. First, we show that this analytical loop closure algorithm can be efficiently combined with an existing loop-construction algorithm to sample loops longer than three residues. Second, we show that Monte Carlo minimization is made severalfold more efficient by employing the local moves generated by the loop closure algorithm, when applied to the global minimization of an eight-residue loop. Our loop closure algorithm is freely available at http://dillgroup. ucsf.edu/loop_closure/. Copyright 2004 Wiley Periodicals, Inc. J Comput Chem 25: 510-528, 2004

  2. The Wilson loop and some applications

    International Nuclear Information System (INIS)

    Bezerra, V.B.

    1983-01-01

    A simple relation between the classical Wilson loop and the angular deviation in the parallel shift is found. An example of potential which given field copies and which give the same classical Wilson loop for a given trajectory is exchibited. Afterwards, the asymptotic behaviour of the Wilson loop for the BPST instanton and meron is discussed. Using the dimensional regularization technique to calculate the second order term of Quantum Wilson loop, the influence of geometrical factors for the residue in the polo due to contact points, cusp and intersections, in function of the upsilon dimension of the space-time is investigated. Finally, the charge renormalization in Quantum Electrodynamics using Quantum Wilson loop is calculated. (L.C.) [pt

  3. The Wilson loop and some applications

    International Nuclear Information System (INIS)

    Bezerra, V.B.

    1983-04-01

    A simple relation between the classical Wilson loop and the angular deviation in the parallel displacement is found. An example of potentials which give field copies and which suplly the same classical Wilson loop for a particular trajectory is exhibited. The asymptotic behaviour of the Wilson loop for the BPST instanton and the meron, is discussed. By using the dimensional regularization technique to calculate the second order term of the quantum Wilson loop, the influence of geometrical factors for the residue in the pole due to contact points, cuspides and intersections, in function of the space-time ν, is investigated. Charge renormalization in Quantum electrodynamics is finally calculated by using the quantum Wilson loop. (L.C.) [pt

  4. Hepatic abscess versus peripheral cholangiocarcinoma: Sonographic differentiation

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hwan Hoon; Kim, Yun Hwan; Kang, Chang Ho; Chung, Kyoo Byung; Suh, Won Hyuck [Korea University College of Medicine, Seoul (Korea, Republic of); Lee, Chang Hee [Kunkuk University College of Medicine, Chung-Ju Hospital, Chung-Ju (Korea, Republic of)

    2000-12-15

    To find out the sonographic findings that are useful to differentiate hepatic abscess from peripheral cholangiocarcinoma. Twenty-two hepatic abscesses and 22 peripheral cholangiocarcinomas which had been confirmed histologically were included in this study. Objective points were echo characteristics of the lesion, internal septation, presence of peripheral low echoic rim, demarcation from normal liver(well or poorly defined), posterior enhancement, multiplicity, dilatation of bile duct(obstructive or non-obstructive), intrahepatic duct stone, pleural effusion, and intra-abdominal fluid collection. Echo characteristics of the lesion were classified in-to four types. Type I; Predominantly echogenic with hypoechoic portion, type II; Echogenic without hypoechoic portion, type III; Predominantly hypoechoic with echogenic portion, type IV; Hypoechoic without echogenic portion. 1)Nine abscesses and 2 peripheral cholangiocarcinomas were type I(p=0.037), 2)One abscess and 18 peripheral cholangiocarcinomas were type II(p=0.001), 3)Seven abscesses and none of peripheral cholangiocarcinomas were type III(p=0.001), 4)Five abscesses and 2 peripheral cholangiocarcinomas were type IV(p=0.410). Only 7 abscesses showed internal septations(p=0.013). One abscess and 9 peripheral cholangiocarcinomas showed peripheral hypoechoic halos(p=0.012). Only 9 peripheral cholangiocarcinomas showed obstructive bile duct dilatation (p=0.001). There were no statistically significant differences between abscess and peripheral cholangiocarcinoma on other objective points. Predominantly echogenic with hypoechoic portion, predominantly hypoechoic with echogenic portion, and internal septation are the features suggestive of hepatic abscess, and echogenic without hypoechoic portion, peripheral hypoechoic halo, obstructive bile duct dilatation are suggestive of peripheral cholangiocarcinoma. Therefore these sonographic findings are helpful to differentiate hepatic abscess from peripheral

  5. An experimental study of dislocation loop nucleation

    International Nuclear Information System (INIS)

    Bounaud, J.Y.; Leteurtre, J.

    1975-01-01

    The nucleation of dislocation loops is experimentally studied by observing the demixion of the Burgers vectors of dislocation loops nucleated in copper whiskers irradiated in flexion by fission fragments at room temperature. The demixion of Burgers vectors is observed by the dimensional effects of dislocation loops: after irradiation, the applied stress is removed; the whisker shows a residual strain that is due to loops because, after an annealing treatment to evaporate dislocation loops, each whisker recovers its initial straight shape. Everywhere along the whisker, the radius of curvature is measured and plotted vs the max. applied stress. Estimations of the interstitial and vacancy dislocation loop nuclei are derived [fr

  6. Repertoire Analysis of Antibody CDR-H3 Loops Suggests Affinity Maturation Does Not Typically Result in Rigidification

    Directory of Open Access Journals (Sweden)

    Jeliazko R. Jeliazkov

    2018-03-01

    Full Text Available Antibodies can rapidly evolve in specific response to antigens. Affinity maturation drives this evolution through cycles of mutation and selection leading to enhanced antibody specificity and affinity. Elucidating the biophysical mechanisms that underlie affinity maturation is fundamental to understanding B-cell immunity. An emergent hypothesis is that affinity maturation reduces the conformational flexibility of the antibody’s antigen-binding paratope to minimize entropic losses incurred upon binding. In recent years, computational and experimental approaches have tested this hypothesis on a small number of antibodies, often observing a decrease in the flexibility of the complementarity determining region (CDR loops that typically comprise the paratope and in particular the CDR-H3 loop, which contributes a plurality of antigen contacts. However, there were a few exceptions and previous studies were limited to a small handful of cases. Here, we determined the structural flexibility of the CDR-H3 loop for thousands of recent homology models of the human peripheral blood cell antibody repertoire using rigidity theory. We found no clear delineation in the flexibility of naïve and antigen-experienced antibodies. To account for possible sources of error, we additionally analyzed hundreds of human and mouse antibodies in the Protein Data Bank through both rigidity theory and B-factor analysis. By both metrics, we observed only a slight decrease in the CDR-H3 loop flexibility when comparing affinity matured antibodies to naïve antibodies, and the decrease was not as drastic as previously reported. Further analysis, incorporating molecular dynamics simulations, revealed a spectrum of changes in flexibility. Our results suggest that rigidification may be just one of many biophysical mechanisms for increasing affinity.

  7. Coupling between feedback loops in autoregulatory networks affects bistability range, open-loop gain and switching times

    International Nuclear Information System (INIS)

    Tiwari, Abhinav; Igoshin, Oleg A

    2012-01-01

    Biochemical regulatory networks governing diverse cellular processes such as stress-response, differentiation and cell cycle often contain coupled feedback loops. We aim at understanding how features of feedback architecture, such as the number of loops, the sign of the loops and the type of their coupling, affect network dynamical performance. Specifically, we investigate how bistability range, maximum open-loop gain and switching times of a network with transcriptional positive feedback are affected by additive or multiplicative coupling with another positive- or negative-feedback loop. We show that a network's bistability range is positively correlated with its maximum open-loop gain and that both quantities depend on the sign of the feedback loops and the type of feedback coupling. Moreover, we find that the addition of positive feedback could decrease the bistability range if we control the basal level in the signal-response curves of the two systems. Furthermore, the addition of negative feedback has the capacity to increase the bistability range if its dissociation constant is much lower than that of the positive feedback. We also find that the addition of a positive feedback to a bistable network increases the robustness of its bistability range, whereas the addition of a negative feedback decreases it. Finally, we show that the switching time for a transition from a high to a low steady state increases with the effective fold change in gene regulation. In summary, we show that the effect of coupled feedback loops on the bistability range and switching times depends on the underlying mechanistic details. (paper)

  8. Gauge theory loop operators and Liouville theory

    Energy Technology Data Exchange (ETDEWEB)

    Drukker, Nadav [Humboldt Univ. Berlin (Germany). Inst. fuer Physik; Gomis, Jaume; Okuda, Takuda [Perimeter Inst. for Theoretical Physics, Waterloo, ON (Canada); Teschner, Joerg [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2009-10-15

    We propose a correspondence between loop operators in a family of four dimensional N=2 gauge theories on S{sup 4} - including Wilson, 't Hooft and dyonic operators - and Liouville theory loop operators on a Riemann surface. This extends the beautiful relation between the partition function of these N=2 gauge theories and Liouville correlators found by Alday, Gaiotto and Tachikawa. We show that the computation of these Liouville correlators with the insertion of a Liouville loop operator reproduces Pestun's formula capturing the expectation value of a Wilson loop operator in the corresponding gauge theory. We prove that our definition of Liouville loop operators is invariant under modular transformations, which given our correspondence, implies the conjectured action of S-duality on the gauge theory loop operators. Our computations in Liouville theory make an explicit prediction for the exact expectation value of 't Hooft and dyonic loop operators in these N=2 gauge theories. The Liouville loop operators are also found to admit a simple geometric interpretation within quantum Teichmueller theory as the quantum operators representing the length of geodesics. We study the algebra of Liouville loop operators and show that it gives evidence for our proposal as well as providing definite predictions for the operator product expansion of loop operators in gauge theory. (orig.)

  9. Relating loop quantum cosmology to loop quantum gravity: symmetric sectors and embeddings

    International Nuclear Information System (INIS)

    Engle, J

    2007-01-01

    In this paper we address the meaning of states in loop quantum cosmology (LQC), in the context of loop quantum gravity. First, we introduce a rigorous formulation of an embedding proposed by Bojowald and Kastrup, of LQC states into loop quantum gravity. Then, using certain holomorphic representations, a new class of embeddings, called b-embeddings, are constructed, following the ideas of Engle (2006 Quantum field theory and its symmetry reduction Class. Quantum Gravity 23 2861-94). We exhibit a class of operators preserving each of these embeddings, and show their consistency with the LQC quantization. In the b-embedding case, the classical analogues of these operators separate points in phase space. Embedding at the gauge and diffeomorphism invariant level is discussed briefly in the conclusions

  10. DNA looping by FokI: the impact of twisting and bending rigidity on protein-induced looping dynamics

    Science.gov (United States)

    Laurens, Niels; Rusling, David A.; Pernstich, Christian; Brouwer, Ineke; Halford, Stephen E.; Wuite, Gijs J. L.

    2012-01-01

    Protein-induced DNA looping is crucial for many genetic processes such as transcription, gene regulation and DNA replication. Here, we use tethered-particle motion to examine the impact of DNA bending and twisting rigidity on loop capture and release, using the restriction endonuclease FokI as a test system. To cleave DNA efficiently, FokI bridges two copies of an asymmetric sequence, invariably aligning the sites in parallel. On account of the fixed alignment, the topology of the DNA loop is set by the orientation of the sites along the DNA. We show that both the separation of the FokI sites and their orientation, altering, respectively, the twisting and the bending of the DNA needed to juxtapose the sites, have profound effects on the dynamics of the looping interaction. Surprisingly, the presence of a nick within the loop does not affect the observed rigidity of the DNA. In contrast, the introduction of a 4-nt gap fully relaxes all of the torque present in the system but does not necessarily enhance loop stability. FokI therefore employs torque to stabilise its DNA-looping interaction by acting as a ‘torsional’ catch bond. PMID:22373924

  11. Water loop for training

    International Nuclear Information System (INIS)

    Moeller, S.V.

    1983-02-01

    The procedures used to operate the water loop of the Institute of Nuclear Enginering (IEN) in Brazil are presented. The aim is to help future operators of the training water loop in the operation technique and in a better comprehension of the phenomena occured during the execution of an experience. (E.G.) [pt

  12. Loop equations in the theory of gravitation

    International Nuclear Information System (INIS)

    Makeenko, Yu.M.; Voronov, N.A.

    1981-01-01

    Loop-space variables (matrices of parallel transport) for the theory of gravitation are described. Loop equations, which are equivalent to the Einstein equations, are derived in the classical case. Loop equations are derived for gravity with cosmological constant as well. An analogy with the loop-space approach in Yang-Mills theory is discussed [ru

  13. Tritium Management Loop Design Status

    Energy Technology Data Exchange (ETDEWEB)

    Rader, Jordan D. [ORNL; Felde, David K. [ORNL; McFarlane, Joanna [ORNL; Greenwood, Michael Scott [ORNL; Qualls, A L. [ORNL; Calderoni, Pattrick [Idaho National Laboratory (INL)

    2017-12-01

    This report summarizes physical, chemical, and engineering analyses that have been done to support the development of a test loop to study tritium migration in 2LiF-BeF2 salts. The loop will operate under turbulent flow and a schematic of the apparatus has been used to develop a model in Mathcad to suggest flow parameters that should be targeted in loop operation. The introduction of tritium into the loop has been discussed as well as various means to capture or divert the tritium from egress through a test assembly. Permeation was calculated starting with a Modelica model for a transport through a nickel window into a vacuum, and modifying it for a FLiBe system with an argon sweep gas on the downstream side of the permeation interface. Results suggest that tritium removal with a simple tubular permeation device will occur readily. Although this system is idealized, it suggests that rapid measurement capability in the loop may be necessary to study and understand tritium removal from the system.

  14. Criteria for saturated magnetization loop

    International Nuclear Information System (INIS)

    Harres, A.; Mikhov, M.; Skumryev, V.; Andrade, A.M.H. de; Schmidt, J.E.; Geshev, J.

    2016-01-01

    Proper estimation of magnetization curve parameters is vital in studying magnetic systems. In the present article, criteria for discrimination non-saturated (minor) from saturated (major) hysteresis loops are proposed. These employ the analysis of (i) derivatives of both ascending and descending branches of the loop, (ii) remanent magnetization curves, and (iii) thermomagnetic curves. Computational simulations are used in order to demonstrate their validity. Examples illustrating the applicability of these criteria to well-known real systems, namely Fe_3O_4 and Ni fine particles, are provided. We demonstrate that the anisotropy-field value estimated from a visual examination of an only apparently major hysteresis loop could be more than two times lower than the real one. - Highlights: • Proper estimation of hysteresis-loop parameters is vital in magnetic studies. • We propose criteria for discrimination minor from major hysteresis loops. • The criteria analyze magnetization, remanence and ZFC/FC curves and/or their derivatives. • Examples of their application on real nanoparticles systems are given. • Using the criteria could avoid twofold or bigger saturation-field underestimation errors.

  15. Criteria for saturated magnetization loop

    Energy Technology Data Exchange (ETDEWEB)

    Harres, A. [Departamento de Física, UFSM, Santa Maria, 97105-900 Rio Grande do Sul (Brazil); Mikhov, M. [Faculty of Physics, University of Sofia, 1164 Sofia (Bulgaria); Skumryev, V. [Institució Catalana de Recerca i Estudis Avançats, 08010 Barcelona (Spain); Departament de Física, Universitat Autònoma de Barcelona, 08193 Barcelona (Spain); Andrade, A.M.H. de; Schmidt, J.E. [Instituto de Física, UFRGS, Porto Alegre, 91501-970 Rio Grande do Sul (Brazil); Geshev, J., E-mail: julian@if.ufrgs.br [Departament de Física, Universitat Autònoma de Barcelona, 08193 Barcelona (Spain); Instituto de Física, UFRGS, Porto Alegre, 91501-970 Rio Grande do Sul (Brazil)

    2016-03-15

    Proper estimation of magnetization curve parameters is vital in studying magnetic systems. In the present article, criteria for discrimination non-saturated (minor) from saturated (major) hysteresis loops are proposed. These employ the analysis of (i) derivatives of both ascending and descending branches of the loop, (ii) remanent magnetization curves, and (iii) thermomagnetic curves. Computational simulations are used in order to demonstrate their validity. Examples illustrating the applicability of these criteria to well-known real systems, namely Fe{sub 3}O{sub 4} and Ni fine particles, are provided. We demonstrate that the anisotropy-field value estimated from a visual examination of an only apparently major hysteresis loop could be more than two times lower than the real one. - Highlights: • Proper estimation of hysteresis-loop parameters is vital in magnetic studies. • We propose criteria for discrimination minor from major hysteresis loops. • The criteria analyze magnetization, remanence and ZFC/FC curves and/or their derivatives. • Examples of their application on real nanoparticles systems are given. • Using the criteria could avoid twofold or bigger saturation-field underestimation errors.

  16. Capillary-Condenser-Pumped Heat-Transfer Loop

    Science.gov (United States)

    Silverstein, Calvin C.

    1989-01-01

    Heat being transferred supplies operating power. Capillary-condenser-pumped heat-transfer loop similar to heat pipe and to capillary-evaporator-pumped heat-transfer loop in that heat-transfer fluid pumped by evaporation and condensation of fluid at heat source and sink, respectively. Capillary condenser pump combined with capillary evaporator pump to form heat exchanger circulating heat-transfer fluids in both loops. Transport of heat more nearly isothermal. Thermal stress in loop reduced, and less external surface area needed in condenser section for rejection of heat to heat sink.

  17. Quantum chromodynamics as dynamics of loops

    International Nuclear Information System (INIS)

    Makeenko, Yu.; Migdal, A.A.

    1980-01-01

    The problem of a possibility of reformulating quantum chromodynamics (QCD) in terms of colourless composite fields instead of coloured quarks and gluons is considered. The role of such fields is played by the gauge invariant loop functionals. The Shwinger equations of motion is derived in the loop space which completely describe dynamics of the loop fields. New manifestly gauge invariant diagram technique in the loop space is developed. These diagrams reproduce asymptotic freedom in the ultraviolet range and are consistent with the confinement law in the infrared range

  18. Abnormal duodenal loop demonstrated by X-ray

    International Nuclear Information System (INIS)

    Thommesen, P.; Funch-Jensen, P.

    1986-01-01

    The occurrence of dyspeptic symptoms has previously been correlated with the shape of the duodenal loop in patients with X-ray-negative dyspepsia. An abnormal duodenal loop was associated with a significantly higher incidence of symtoms provoked by meals, vomiting, regurgitations, heartburn, and the irritable bowel syndrome. 89% of these patients (26 patients with a normal duodenal loop and 39 patients with abnormal duodenal loop) were available for a 5-year follow-up study of symptomatic outcome. The incidence of symptoms provoked by meals was still significantly higher in patients with an abnormal duodenal loop, and there was also a significant difference concerning symptomatic outcome. Approximately 75% of the patients with a normal duodenal loop had improved, and 25% had unchanged clinical conditions. Approximately 50% of the patients with an abnormal duodenal loop had improved, and 50% had an unchanged or even deteriorated clinical condition

  19. Kalman Orbit Optimized Loop Tracking

    Science.gov (United States)

    Young, Lawrence E.; Meehan, Thomas K.

    2011-01-01

    Under certain conditions of low signal power and/or high noise, there is insufficient signal to noise ratio (SNR) to close tracking loops with individual signals on orbiting Global Navigation Satellite System (GNSS) receivers. In addition, the processing power available from flight computers is not great enough to implement a conventional ultra-tight coupling tracking loop. This work provides a method to track GNSS signals at very low SNR without the penalty of requiring very high processor throughput to calculate the loop parameters. The Kalman Orbit-Optimized Loop (KOOL) tracking approach constitutes a filter with a dynamic model and using the aggregate of information from all tracked GNSS signals to close the tracking loop for each signal. For applications where there is not a good dynamic model, such as very low orbits where atmospheric drag models may not be adequate to achieve the required accuracy, aiding from an IMU (inertial measurement unit) or other sensor will be added. The KOOL approach is based on research JPL has done to allow signal recovery from weak and scintillating signals observed during the use of GPS signals for limb sounding of the Earth s atmosphere. That approach uses the onboard PVT (position, velocity, time) solution to generate predictions for the range, range rate, and acceleration of the low-SNR signal. The low- SNR signal data are captured by a directed open loop. KOOL builds on the previous open loop tracking by including feedback and observable generation from the weak-signal channels so that the MSR receiver will continue to track and provide PVT, range, and Doppler data, even when all channels have low SNR.

  20. Peripheral visual performance enhancement by neurofeedback training.

    Science.gov (United States)

    Nan, Wenya; Wan, Feng; Lou, Chin Ian; Vai, Mang I; Rosa, Agostinho

    2013-12-01

    Peripheral visual performance is an important ability for everyone, and a positive inter-individual correlation is found between the peripheral visual performance and the alpha amplitude during the performance test. This study investigated the effect of alpha neurofeedback training on the peripheral visual performance. A neurofeedback group of 13 subjects finished 20 sessions of alpha enhancement feedback within 20 days. The peripheral visual performance was assessed by a new dynamic peripheral visual test on the first and last training day. The results revealed that the neurofeedback group showed significant enhancement of the peripheral visual performance as well as the relative alpha amplitude during the peripheral visual test. It was not the case in the non-neurofeedback control group, which performed the tests within the same time frame as the neurofeedback group but without any training sessions. These findings suggest that alpha neurofeedback training was effective in improving peripheral visual performance. To the best of our knowledge, this is the first study to show evidence for performance improvement in peripheral vision via alpha neurofeedback training.

  1. LOOP: engineering marvel, economic calamity

    Energy Technology Data Exchange (ETDEWEB)

    Brossard, E B

    1985-01-01

    The Louisiana Offshore Oil Port (LOOP) is the first superport built in the Lower 48. The United States was the only major oil-importing country that did not have a superport, and therefore, could not offload very large crude carriers (VLCCs). Unfortunately, a number of factors changed after it was decided to build LOOP, and these, plus the onerous provisions of the Deepwater Ports Act of 1974, which authorized superports, prevented LOOP from operating economically. LOOP's facilities consist of an offshore platform complex with three single-point-mooring (SPM) system buoys, 19 miles offshore in 110 feet of water, as well as a 32-million-barrel storage terminal 31 miles inland at Clovelly Salt Dome, and connecting pipelines offshore and onshore. By the time LOOP was started-up in May 1981, demand for oil had declined, because of rises in the price of oil, and the source of US oil imports had shifted back to the western hemisphere, away from the eastern hemisphere, closer to the US. The refinery mix in the US also changed, because of up-grading of a number of big refineries, which further reduced demand and made heavier crudes from countries like Mexico and Venezuela more economical. Because of reduced oil imports and shorter hauls, oil shippers started using or continued to use smaller tankers. Smaller tankers are not economical for LOOP, nor do they need LOOP. The start-up of the Trans-Alaska Pipeline System (TAPS) in mid-1977 backed out 1.5 million bd/sup -1/ of foreign imports. TAPS' capacity coincides with LOOP's offloading capacity of 1.4 million bd/sup -1/. US decontrol of domestic crude in 1981 and increased drilling, plus general energy conservation further reduced US oil imports. US consumption declined to 15.1 million bd/sup -1/ in 1983, from 18.8 million bd/sup -1/ in 1978. This award-winning superport needed federal decontrol and increased oil imports along with more VLCCs, in order to operate economically.

  2. The massless two-loop two-point function

    International Nuclear Information System (INIS)

    Bierenbaum, I.; Weinzierl, S.

    2003-01-01

    We consider the massless two-loop two-point function with arbitrary powers of the propagators and derive a representation from which we can obtain the Laurent expansion to any desired order in the dimensional regularization parameter ε. As a side product, we show that in the Laurent expansion of the two-loop integral only rational numbers and multiple zeta values occur. Our method of calculation obtains the two-loop integral as a convolution product of two primitive one-loop integrals. We comment on the generalization of this product structure to higher loop integrals. (orig.)

  3. Open loop thanks to direct torque control (DTC). Motor control without feedback loop; Open loop dank direkter Drehmomentregelung (DTC). Hochwertige Motorregelung ohne Rueckfuehrung

    Energy Technology Data Exchange (ETDEWEB)

    Link, Michael [ABB Automation Products GmbH, Ladenburg (Germany)

    2009-07-01

    Servo drives are used in various applications. The range of applications is huge and thus also requirements to the drive system. Mainly, a fast torque and speed control is required. This is the domaine of direct torque control (DTC). In many applications DTC can meet this challenge to control the motor with full torque at zero speed. The servo converter based on DTC technology provides a control concept for synchronous and asynchronous motors for both closed loop and open loop control. DTC controlled drives support the whole range from open loop up to high performance motion control applications. (orig.)

  4. The surgery of peripheral nerves (including tumors)

    DEFF Research Database (Denmark)

    Fugleholm, Kåre

    2013-01-01

    Surgical pathology of the peripheral nervous system includes traumatic injury, entrapment syndromes, and tumors. The recent significant advances in the understanding of the pathophysiology and cellular biology of peripheral nerve degeneration and regeneration has yet to be translated into improved...... surgical techniques and better outcome after peripheral nerve injury. Decision making in peripheral nerve surgery continues to be a complex challenge, where the mechanism of injury, repeated clinical evaluation, neuroradiological and neurophysiological examination, and detailed knowledge of the peripheral...... nervous system response to injury are prerequisite to obtain the best possible outcome. Surgery continues to be the primary treatment modality for peripheral nerve tumors and advances in adjuvant oncological treatment has improved outcome after malignant peripheral nerve tumors. The present chapter...

  5. Peripheral Circulatory Features during High-Frequency Jet Ventilation

    Directory of Open Access Journals (Sweden)

    M. B. Kontorovich

    2010-01-01

    Full Text Available The paper gives the results of a study of peripheral circulatory features during high-frequency jet ventilation (HFJV. The main specific features of peripheral circulation and oxygen transport during HFJV are formulated on the basis of a study of cardiac output (impedance cardiography, peripheral vascular resistance, peripheral vascular blood filling (photoplethysmogram analysis, adaptive peripheral blood flow reactions (spectral analysis of peripheral vascular pulsation. HFJV gives rise to the peculiar pattern of peripheral hemodynamics and tissue gas exchange, which is characterized by higher oxygen uptake without a decrease in mixed venous blood saturation, with normal extraction coefficient and preserved low peripheral vascular resistance. During HFJV, unlike traditional ventilation, the main peripheral hemodynamic feature is the increased capillary bed blood volume caused by the blood flow involvement of reserve capillaries under control of volume (parasympathetic regulation of adaptive peripheral hemodynamic reactions. Key words: high-frequency jet ventilation, oxygen transport, peripheral hemodynamics.

  6. Use of tripolar electrodes for minimization of current spread in uncut peripheral nerve stimulation.

    Science.gov (United States)

    Ohsawa, Ichiro; Inui, Koji

    2009-05-01

    The electrical stimulation of an uncut peripheral nerve requires a countermeasure to avoid the spread of current through a loop pathway formed outside the electrode array. Here the use of tripolar electrodes (TE) is proposed. By binding the two end poles, current spread through the loop pathway can theoretically be eliminated since both end poles are held equipotential. Experimentally, we tested the validity of this approach. In chloralose-urethane anesthetized rats, the left cervical vagus (LCV) was placed on TE which could function as such or as bipolar electrodes (BE) by the use of a selector switch. The spread of current to the adjacent tissues (rectus capitis muscle underlying the LCV, and the right cervical vagus (RCV) incised and translocated beside the target, LCV) was compared between TE and BE. When the stimulus intensity was increased, contraction occurred in the capitis muscle with BE, but not TE. Compound spike potentials of A fiber origin were evoked in the non-target RCV on high-intensity stimulation with BE, but not TE. Constant voltage stimulation of the LCV with TE produced bradycardia of the same magnitude as that with BE. In conclusion, constant voltage stimulation using TE can minimize current spread without changing the stimulus's effects.

  7. Stability, structure, and evolution of cool loops

    International Nuclear Information System (INIS)

    Cally, P.S.; Robb, T.D.

    1991-01-01

    The criteria for the existence and stability of cool loops are reexamined. It is found that the stability of the loops strongly depends on the form of the heating and radiative loss functions and that if the Ly-alpha peak which appears in most calculations of the radiative loss function is real, cool loops are almost certainly unstable. Removing the hydrogen contribution from the recent loss function Q(T) by Cook et al. (1989) does not produce the much-used result, Q proportional to T-cubed, which is so favorable to cool loop stability. Even using the probably unrealistically favorable loss function Q1 of Cook et al. with the hydrogen contribution removed, the maximum temperature attainable in stable cool loops is a factor of 2-3 too small to account for the excess emission observed in lower transition region lines. Dynamical simulations of cool loop instabilities reveal that the final state of such a model is the hot loop equilibrium. 26 refs

  8. Conformal anomaly of super Wilson loop

    Energy Technology Data Exchange (ETDEWEB)

    Belitsky, A.V., E-mail: andrei.belitsky@asu.edu [Department of Physics, Arizona State University, Tempe, AZ 85287-1504 (United States)

    2012-09-11

    Classically supersymmetric Wilson loop on a null polygonal contour possesses all symmetries required to match it onto non-MHV amplitudes in maximally supersymmetric Yang-Mills theory. However, to define it quantum mechanically, one is forced to regularize it since perturbative loop diagrams are not well defined due to presence of ultraviolet divergences stemming from integration in the vicinity of the cusps. A regularization that is adopted by practitioners by allowing one to use spinor helicity formalism, on the one hand, and systematically go to higher orders of perturbation theory is based on a version of dimensional regularization, known as Four-Dimensional Helicity scheme. Recently it was demonstrated that its use for the super Wilson loop at one loop breaks both conformal symmetry and Poincare supersymmetry. Presently, we exhibit the origin for these effects and demonstrate how one can undo this breaking. The phenomenon is alike the one emerging in renormalization group mixing of conformal operators in conformal theories when one uses dimensional regularization. The rotation matrix to the diagonal basis is found by means of computing the anomaly in the Ward identity for the conformal boost. Presently, we apply this ideology to the super Wilson loop. We compute the one-loop conformal anomaly for the super Wilson loop and find that the anomaly depends on its Grassmann coordinates. By subtracting this anomalous contribution from the super Wilson loop we restore its interpretation as a dual description for reduced non-MHV amplitudes which are expressed in terms of superconformal invariants.

  9. Fundamental and Harmonic Oscillations in Neighboring Coronal Loops

    Science.gov (United States)

    Li, Hongbo; Liu, Yu; Vai Tam, Kuan

    2017-06-01

    We present observations of multimode (fundamental and harmonic) oscillations in a loop system, which appear to be simultaneously excited by a GOES C-class flare. Analysis of the periodic oscillations reveals that (1) the primary loop with a period of P a ≈ 4 minutes and a secondary loop with two periods of P a ≈ 4 minutes and P b ≈ 2 minutes are detected simultaneously in closely spaced loop strands; (2) both oscillation components have their peak amplitudes near the loop apex, while in the second loop the low-frequency component P a dominates in a loop segment that is two times larger than the high-frequency component P b ; (3) the harmonic mode P b shows the largest deviation from a sinusoidal loop shape at the loop apex. We conclude that multiple harmonic modes with different displacement profiles can be excited simultaneously even in closely spaced strands, similar to the overtones of a violin string.

  10. Soft Neutrosophic Loops and Their Generalization

    Directory of Open Access Journals (Sweden)

    Mumtaz Ali

    2014-06-01

    Full Text Available Soft set theory is a general mathematical tool for dealing with uncertain, fuzzy, not clearly defined objects. In this paper we introduced soft neutrosophic loop,soft neutosophic biloop, soft neutrosophic N -loop with the discuission of some of their characteristics. We also introduced a new type of soft neutrophic loop, the so called soft strong neutrosophic loop which is of pure neutrosophic character. This notion also found in all the other corresponding notions of soft neutrosophic thoery. We also given some of their properties of this newly born soft structure related to the strong part of neutrosophic theory.

  11. Two- and three-loop amplitudes in covariant loop calculus

    International Nuclear Information System (INIS)

    Roland, K.

    1988-04-01

    We study 2- and 3-loop vacuum-amplitudes for the closed bosonic string. We compare two sets of expressions for the corresponding density on moduli space: One, based on the covariant Reggeon loop calculus (where modular invariance is not manifest). The other, based on analytic geometry. We want to prove identity between the two sets of expressions. Quite apart from demonstrating modular invariance of the Reggeon results, this would in itself be a remarkable mathematical feature. Identity is established to 'high' order in some moduli and exactly in others. The expansions reveal an essentially number-theoretical structure. Agreement is found only by exploiting the connection between the 4 Jacobi θ-functions and number theory. (orig.)

  12. Two- and three-loop amplitudes in covariant loop calculus

    International Nuclear Information System (INIS)

    Roland, K.

    1989-01-01

    We study two- and three-loop vacuum amplitudes for the closed bosonic string. We compare two sets of expressions for the corresponding density on moduli space. One is based on the covariant reggeon loop calculus (where modular invariance is not manifest). The other is based on analytic geometry. We want to prove identity between the two sets of expressions. Quite apart from demonstrating modular invariance of the reggeon results, this would in itself be a remarkable mathematical feature. Identity is established to ''high'' order in some moduli and exactly in others. The expansions reveal an essentially number-theoretic structure. Agreement is found only by exploiting the connection between the four Jacobi θ-functions and number theory. (orig.)

  13. Loop Quantum Gravity

    Directory of Open Access Journals (Sweden)

    Rovelli Carlo

    1998-01-01

    Full Text Available The problem of finding the quantum theory of the gravitational field, and thus understanding what is quantum spacetime, is still open. One of the most active of the current approaches is loop quantum gravity. Loop quantum gravity is a mathematically well-defined, non-perturbative and background independent quantization of general relativity, with its conventional matter couplings. Research in loop quantum gravity today forms a vast area, ranging from mathematical foundations to physical applications. Among the most significant results obtained are: (i The computation of the physical spectra of geometrical quantities such as area and volume, which yields quantitative predictions on Planck-scale physics. (ii A derivation of the Bekenstein-Hawking black hole entropy formula. (iii An intriguing physical picture of the microstructure of quantum physical space, characterized by a polymer-like Planck scale discreteness. This discreteness emerges naturally from the quantum theory and provides a mathematically well-defined realization of Wheeler's intuition of a spacetime ``foam''. Long standing open problems within the approach (lack of a scalar product, over-completeness of the loop basis, implementation of reality conditions have been fully solved. The weak part of the approach is the treatment of the dynamics: at present there exist several proposals, which are intensely debated. Here, I provide a general overview of ideas, techniques, results and open problems of this candidate theory of quantum gravity, and a guide to the relevant literature.

  14. Estimation of complex permittivity using loop antenna

    DEFF Research Database (Denmark)

    Lenler-Eriksen, Hans-Rudolph; Meincke, Peter

    2004-01-01

    A method for estimating the complex permittivity of materials in the vicinity of a loop antenna is proposed. The method is based on comparing measured and numerically calculated input admittances for the loop antenna.......A method for estimating the complex permittivity of materials in the vicinity of a loop antenna is proposed. The method is based on comparing measured and numerically calculated input admittances for the loop antenna....

  15. Peripherally applied opioids for postoperative pain

    DEFF Research Database (Denmark)

    Nielsen, B N; Henneberg, S W; Schmiegelow, K

    2015-01-01

    BACKGROUND: Opioids applied peripherally at the site of surgery may produce postoperative analgesia with few side effects. We performed this systematic review to evaluate the analgesic effect of peripherally applied opioids for acute postoperative pain. METHODS: We searched PubMed (1966 to June...... 2013), Embase (1980 to June 2013), and the Cochrane Central Register of Controlled Trials (The Cochrane Library 2013, Issue 6). Randomized controlled trials investigating the postoperative analgesic effect of peripherally applied opioids vs. systemic opioids or placebo, measured by pain intensity...... difference -5 mm, 95% CI: -7 to -3) for peripherally applied opioids vs. placebo and statistically significant increased time to first analgesic (mean difference 153 min, 95% CI: 41-265). When preoperative inflammation was reported (five studies), peripherally applied opioids significantly improved...

  16. Functional Fourier transforms and the loop equation

    International Nuclear Information System (INIS)

    Bershadskii, M.A.; Vaisburd, I.D.; Migdal, A.A.

    1986-01-01

    The Migdal-Makeenko momentum-space loop equation is investigated. This equation is derived from the ordinary loop equation by taking the Fourier transform of the Wilson functional. A perturbation theory is constructed for the new equation and it is proved that the action of the loop operator is determined by vertex functions which coincide with those of the previous equation. It is shown how the ghost loop arises in direct iterations of the momentum-space equation with respect to the coupling constant. A simple example is used to illustrate the mechanism of appearance of an integration in the interior loops in transition to observables

  17. Loop Evolution Observed with AIA and Hi-C

    Science.gov (United States)

    Mulu-Moore, Fana; Winebarger, Amy R.; Cirtain, Jonathan W.; Kobayashi, Ken; Korreck, Kelly E.; Golub, Leon; Kuzin, Sergei; Walsh, Robert William; DeForest, Craig E.; De Pontieu, Bart; hide

    2012-01-01

    In the past decade, the evolution of EUV loops has been used to infer the loop substructure. With the recent launch of High Resolution Coronal Imager (Hi-C), this inference can be validated. In this presentation we discuss the first results of loop analysis comparing AIA and Hi-C data. In the past decade, the evolution of EUV loops has been used to infer the loop substructure. With the recent launch of High Resolution Coronal Imager (Hi-C), this inference can be validated. In this presentation we discuss the first results of loop analysis comparing AIA and Hi-C data.

  18. Burn-related peripheral neuropathy: A systematic review.

    Science.gov (United States)

    Tu, Yiji; Lineaweaver, William C; Zheng, Xianyou; Chen, Zenggan; Mullins, Fred; Zhang, Feng

    2017-06-01

    Peripheral neuropathy is the most frequent disabling neuromuscular complication of burns. However, the insidious and progressive onset of burn neuropathy makes it often undiagnosed or overlooked. In our study, we reviewed the current studies on the burn-related peripheral neuropathy to summarize the morbidity, mechanism, detecting method and management of peripheral neuropathy in burn patients. Of the 1533 burn patients included in our study, 98 cases (6.39%) were presented with peripheral neuropathy. Thermal and electrical burns were the most common etiologies. Surgical procedures, especially nerve decompression, showed good effect on functional recovery of both acute and delayed peripheral neuropathy in burn patients. It is noteworthy that, for early detection and prevention of peripheral neuropathy, electrodiagnostic examinations should be performed on burn patients independent of symptoms. Still, the underlying mechanisms of burn-related peripheral neuropathy remain to be clarified. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  19. Paradigms for restoration of somatosensory feedback via stimulation of the peripheral nervous system.

    Science.gov (United States)

    Pasluosta, Cristian; Kiele, Patrick; Stieglitz, Thomas

    2018-04-01

    The somatosensory system contributes substantially to the integration of multiple sensor modalities into perception. Tactile sensations, proprioception and even temperature perception are integrated to perceive embodiment of our limbs. Damage of somatosensory networks can severely affect the execution of daily life activities. Peripheral injuries are optimally corrected via direct interfacing of the peripheral nerves. Recent advances in implantable devices, stimulation paradigms, and biomimetic sensors enabled the restoration of natural sensations after amputation of the limb. The refinement of stimulation patterns to deliver natural feedback that can be interpreted intuitively such to prescind from long-learning sessions is crucial to function restoration. For this review, we collected state-of-the-art knowledge on the evolution of stimulation paradigms from single fiber stimulation to the eliciting of multisensory sensations. Data from the literature are structured into six sections: (a) physiology of the somatosensory system; (b) stimulation of single fibers; (c) restoral of multisensory percepts; (d) closure of the control loop in hand prostheses; (e) sensory restoration and the sense of embodiment, and (f) methodologies to assess stimulation outcomes. Full functional recovery demands further research on multisensory integration and brain plasticity, which will bring new paradigms for intuitive sensory feedback in the next generation of limb prostheses. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  20. High pressure experimental water loop

    International Nuclear Information System (INIS)

    Grenon, M.

    1958-01-01

    A high pressure experimental water loop has been made for studying the detection and evolution of cladding failure in a pressurized reactor. The loop has been designed for a maximum temperature of 360 deg. C, a maximum of 160 kg/cm 2 and flow rates up to 5 m 3 /h. The entire loop consists of several parts: a main circuit with a canned rotor circulation pump, steam pressurizer, heating tubes, two hydro-cyclones (one de-gasser and one decanter) and one tubular heat exchanger; a continuous purification loop, connected in parallel, comprising pressure reducing valves and resin pots which also allow studies of the stability of resins under pressure, temperature and radiation; following the gas separator is a gas loop for studying the recombination of the radiolytic gases in the steam phase. The preceding circuits, as well as others, return to a low pressure storage circuit. The cold water of the low pressure storage flask is continuously reintroduced into the high pressure main circuit by means of a return pump at a maximum head of 160 kg /cm 2 , and adjusted to the pressurizer level. This loop is also a testing bench for the tight high pressure apparatus. The circulating pump and the connecting flanges (Oak Ridge type) are water-tight. The feed pump and the pressure reducing valves are not; the un-tight ones have a system of leak recovery. To permanently check the tightness the circuit has been fitted with a leak detection system (similar to the HRT one). (author) [fr

  1. Automation of loop amplitudes in numerical approach

    International Nuclear Information System (INIS)

    Fujimoto, J.; Ishikawa, T.; Shimizu, Y.; Kato, K.; Nakazawa, N.; Kaneko, T.

    1997-01-01

    An automatic calculating system GRACE-L1 of one-loop Feynman amplitude is reviewed. This system can be applied to 2 to 2-body one-loop processes. A sample calculation of 2 to 3-body one-loop amplitudes is also presented. (orig.)

  2. Loop-quantum-gravity vertex amplitude.

    Science.gov (United States)

    Engle, Jonathan; Pereira, Roberto; Rovelli, Carlo

    2007-10-19

    Spin foam models are hoped to provide the dynamics of loop-quantum gravity. However, the most popular of these, the Barrett-Crane model, does not have the good boundary state space and there are indications that it fails to yield good low-energy n-point functions. We present an alternative dynamics that can be derived as a quantization of a Regge discretization of Euclidean general relativity, where second class constraints are imposed weakly. Its state space matches the SO(3) loop gravity one and it yields an SO(4)-covariant vertex amplitude for Euclidean loop gravity.

  3. THE CORONAL LOOP INVENTORY PROJECT: EXPANDED ANALYSIS AND RESULTS

    Energy Technology Data Exchange (ETDEWEB)

    Schmelz, J. T. [USRA, 7178 Columbia Gateway Drive, Columbia, MD 21046 (United States); Christian, G. M.; Chastain, R. A., E-mail: jschmelz@usra.edu [Physics Department, University of Memphis, Memphis, TN 38152 (United States)

    2016-11-10

    We have expanded upon earlier work that investigates the relative importance of coronal loops with isothermal versus multithermal cross-field temperature distributions. These results are important for determining if loops have substructure in the form of unresolved magnetic strands. We have increased the number of loops targeted for temperature analysis from 19 to 207 with the addition of 188 new loops from multiple regions. We selected all loop segments visible in the 171 Å images of the Atmospheric Imaging Assembly (AIA) that had a clean background. Eighty-six of the new loops were rejected because they could not be reliably separated from the background in other AIA filters. Sixty-one loops required multithermal models to reproduce the observations. Twenty-eight loops were effectively isothermal, that is, the plasma emission to which AIA is sensitive could not be distinguished from isothermal emission, within uncertainties. Ten loops were isothermal. Also, part of our inventory was one small flaring loop, one very cool loop whose temperature distribution could not be constrained by the AIA data, and one loop with inconclusive results. Our survey can confirm an unexpected result from the pilot study: we found no isothermal loop segments where we could properly use the 171-to-193 ratio method, which would be similar to the analysis done for many loops observed with TRACE and EIT. We recommend caution to observers who assume the loop plasma is isothermal, and hope that these results will influence the direction of coronal heating models and the effort modelers spend on various heating scenarios.

  4. Bootstrapping the Three-Loop Hexagon

    Energy Technology Data Exchange (ETDEWEB)

    Dixon, Lance J.; /CERN /SLAC; Drummond, James M.; /CERN /Annecy, LAPTH; Henn, Johannes M.; /Humboldt U., Berlin /Santa Barbara, KITP

    2011-11-08

    We consider the hexagonal Wilson loop dual to the six-point MHV amplitude in planar N = 4 super Yang-Mills theory. We apply constraints from the operator product expansion in the near-collinear limit to the symbol of the remainder function at three loops. Using these constraints, and assuming a natural ansatz for the symbol's entries, we determine the symbol up to just two undetermined constants. In the multi-Regge limit, both constants drop out from the symbol, enabling us to make a non-trivial confirmation of the BFKL prediction for the leading-log approximation. This result provides a strong consistency check of both our ansatz for the symbol and the duality between Wilson loops and MHV amplitudes. Furthermore, we predict the form of the full three-loop remainder function in the multi-Regge limit, beyond the leading-log approximation, up to a few constants representing terms not detected by the symbol. Our results confirm an all-loop prediction for the real part of the remainder function in multi-Regge 3 {yields} 3 scattering. In the multi-Regge limit, our result for the remainder function can be expressed entirely in terms of classical polylogarithms. For generic six-point kinematics other functions are required.

  5. Lattice QED in the loop space

    International Nuclear Information System (INIS)

    Fort, H.

    1994-01-01

    We present a survey on the state of the art in the formulation of lattice compact QED in the space of loops. In a first part we review our most recent Hamiltonian results which signal a second order transition for (3+1) compact QED. We devote the second part to the Lagrangian loop formalism, showing the equivalence of the recently proposed loop action with the Villain form. (orig.)

  6. Loop quantization as a continuum limit

    International Nuclear Information System (INIS)

    Manrique, Elisa; Oeckl, Robert; Weber, Axel; Zapata, Jose A

    2006-01-01

    We present an implementation of Wilson's renormalization group and a continuum limit tailored for loop quantization. The dynamics of loop-quantized theories is constructed as a continuum limit of the dynamics of effective theories. After presenting the general formalism we show as a first explicit example the 2D Ising field theory, an interacting relativistic quantum field theory with local degrees of freedom quantized by loop quantization techniques

  7. Flat Knitting Loop Deformation Simulation Based on Interlacing Point Model

    Directory of Open Access Journals (Sweden)

    Jiang Gaoming

    2017-12-01

    Full Text Available In order to create realistic loop primitives suitable for the faster CAD of the flat-knitted fabric, we have performed research on the model of the loop as well as the variation of the loop surface. This paper proposes an interlacing point-based model for the loop center curve, and uses the cubic Bezier curve to fit the central curve of the regular loop, elongated loop, transfer loop, and irregular deformed loop. In this way, a general model for the central curve of the deformed loop is obtained. The obtained model is then utilized to perform texture mapping, texture interpolation, and brightness processing, simulating a clearly structured and lifelike deformed loop. The computer program LOOP is developed by using the algorithm. The deformed loop is simulated with different yarns, and the deformed loop is applied to design of a cable stitch, demonstrating feasibility of the proposed algorithm. This paper provides a loop primitive simulation method characterized by lifelikeness, yarn material variability, and deformation flexibility, and facilitates the loop-based fast computer-aided design (CAD of the knitted fabric.

  8. Variational solution of the loop equation in QCD

    International Nuclear Information System (INIS)

    Agishtein, M.E.; Migdal, A.A.

    1988-01-01

    A new technique for the large N loop equation of QCD is worked out. The Wilson loop W(C) is approximated by a Gaussian functional. The parameters are fitted to the loop equation, after which the equation is statisfied up to 0.2%. The resulting Wilson loop corresponds to linearly rising Regge trajectories. The problem of tachyon is still present, but it could be cured by iteration of the loop equation starting from this variational solution. (orig.)

  9. Variational solution of the loop equation in QCD

    International Nuclear Information System (INIS)

    Agishtein, M.E.; Migdal, A.A.

    1988-01-01

    A new technique for the large N loop equation of QCD is worked out. The Wilson loop W(C) is approximated by a Gaussian functional. The parameters are fitted to the loop equation, after which the equation is satisfied up to 0.2%. The resulting Wilson loop corresponds to linearly rising Regge trajectories. The problem of tachyon is still present, but it could be cured by iteration of the loop equation starting from this variational solution

  10. Loop Quantum Cosmology

    Directory of Open Access Journals (Sweden)

    Bojowald Martin

    2008-07-01

    Full Text Available Quantum gravity is expected to be necessary in order to understand situations in which classical general relativity breaks down. In particular in cosmology one has to deal with initial singularities, i.e., the fact that the backward evolution of a classical spacetime inevitably comes to an end after a finite amount of proper time. This presents a breakdown of the classical picture and requires an extended theory for a meaningful description. Since small length scales and high curvatures are involved, quantum effects must play a role. Not only the singularity itself but also the surrounding spacetime is then modified. One particular theory is loop quantum cosmology, an application of loop quantum gravity to homogeneous systems, which removes classical singularities. Its implications can be studied at different levels. The main effects are introduced into effective classical equations, which allow one to avoid the interpretational problems of quantum theory. They give rise to new kinds of early-universe phenomenology with applications to inflation and cyclic models. To resolve classical singularities and to understand the structure of geometry around them, the quantum description is necessary. Classical evolution is then replaced by a difference equation for a wave function, which allows an extension of quantum spacetime beyond classical singularities. One main question is how these homogeneous scenarios are related to full loop quantum gravity, which can be dealt with at the level of distributional symmetric states. Finally, the new structure of spacetime arising in loop quantum gravity and its application to cosmology sheds light on more general issues, such as the nature of time.

  11. Loop Quantum Cosmology

    Directory of Open Access Journals (Sweden)

    Bojowald Martin

    2005-12-01

    Full Text Available Quantum gravity is expected to be necessary in order to understand situations where classical general relativity breaks down. In particular in cosmology one has to deal with initial singularities, i.e., the fact that the backward evolution of a classical space-time inevitably comes to an end after a finite amount of proper time. This presents a breakdown of the classical picture and requires an extended theory for a meaningful description. Since small length scales and high curvatures are involved, quantum effects must play a role. Not only the singularity itself but also the surrounding space-time is then modified. One particular realization is loop quantum cosmology, an application of loop quantum gravity to homogeneous systems, which removes classical singularities. Its implications can be studied at different levels. Main effects are introduced into effective classical equations which allow to avoid interpretational problems of quantum theory. They give rise to new kinds of early universe phenomenology with applications to inflation and cyclic models. To resolve classical singularities and to understand the structure of geometry around them, the quantum description is necessary. Classical evolution is then replaced by a difference equation for a wave function which allows to extend space-time beyond classical singularities. One main question is how these homogeneous scenarios are related to full loop quantum gravity, which can be dealt with at the level of distributional symmetric states. Finally, the new structure of space-time arising in loop quantum gravity and its application to cosmology sheds new light on more general issues such as time.

  12. CHY loop integrands from holomorphic forms

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, Humberto [Facultad de Ciencias Basicas, Universidad Santiago de Cali,Calle 5 62-00 Barrio Pampalinda, Cali, Valle (Colombia); Perimeter Institute for Theoretical Physics,31 Caroline Street N, Waterloo, ON N2L 2Y5 (Canada); Mizera, Sebastian; Zhang, Guojun [Perimeter Institute for Theoretical Physics,31 Caroline Street N, Waterloo, ON N2L 2Y5 (Canada); Department of Physics & Astronomy, University of Waterloo,Waterloo, ON N2L 3G1 (Canada)

    2017-03-16

    Recently, the Cachazo-He-Yuan (CHY) approach for calculating scattering amplitudes has been extended beyond tree level. In this paper, we introduce a way of constructing CHY integrands for Φ{sup 3} theory up to two loops from holomorphic forms on Riemann surfaces. We give simple rules for translating Feynman diagrams into the corresponding CHY integrands. As a complementary result, we extend the L-algorithm, originally introduced in https://arxiv.org/abs/1604.05373, to two loops. Using this approach, we are able to analytically verify our prescription for the CHY integrands up to seven external particles at two loops. In addition, it gives a natural way of extending to higher-loop orders.

  13. Loop quantum cosmology and singularities.

    Science.gov (United States)

    Struyve, Ward

    2017-08-15

    Loop quantum gravity is believed to eliminate singularities such as the big bang and big crunch singularity. This belief is based on studies of so-called loop quantum cosmology which concerns symmetry-reduced models of quantum gravity. In this paper, the problem of singularities is analysed in the context of the Bohmian formulation of loop quantum cosmology. In this formulation there is an actual metric in addition to the wave function, which evolves stochastically (rather than deterministically as the case of the particle evolution in non-relativistic Bohmian mechanics). Thus a singularity occurs whenever this actual metric is singular. It is shown that in the loop quantum cosmology for a homogeneous and isotropic Friedmann-Lemaître-Robertson-Walker space-time with arbitrary constant spatial curvature and cosmological constant, coupled to a massless homogeneous scalar field, a big bang or big crunch singularity is never obtained. This should be contrasted with the fact that in the Bohmian formulation of the Wheeler-DeWitt theory singularities may exist.

  14. Liquid Lead-Bismuth Materials Test Loop

    International Nuclear Information System (INIS)

    Tcharnotskaia, Valentina; Ammerman, Curtt; Darling, Timothy; King, Joe; Li, Ning; Shaw, Don; Snodgrass, Leon; Woloshun, Keith

    2002-01-01

    We designed and built the Liquid Lead-Bismuth Materials Test Loop (MTL) to study the materials behavior in a flow of molten lead-bismuth eutectic (LBE). In this paper we present a description of the loop with main components and their functions. Stress distribution in the piping due to sustained, occasional and expansion loads is shown. The loop is designed so that a difference of 100 deg. C can be attained between the coldest and the hottest parts at a nominal flow rate of 8.84 GPM. Liquid LBE flow can be activated by a mechanical sump pump or by natural convection. In order to maintain a self-healing protective film on the surface of the stainless steel pipe, a certain concentration of oxygen has to be maintained in the liquid metal. We developed oxygen sensors and an oxygen control system to be implemented in the loop. The loop is outfitted with a variety of instruments that are controlled from a computer based data acquisition system. Initial experiments include preconditioning the loop, filling it up with LBE, running at uniform temperature and tuning the oxygen control system. We will present some preliminary results and discuss plans for the future tests. (authors)

  15. Intraoperative Ultrasound for Peripheral Nerve Applications.

    Science.gov (United States)

    Willsey, Matthew; Wilson, Thomas J; Henning, Phillip Troy; Yang, Lynda J-S

    2017-10-01

    Offering real-time, high-resolution images via intraoperative ultrasound is advantageous for a variety of peripheral nerve applications. To highlight the advantages of ultrasound, its extraoperative uses are reviewed. The current intraoperative uses, including nerve localization, real-time evaluation of peripheral nerve tumors, and implantation of leads for peripheral nerve stimulation, are reviewed. Although intraoperative peripheral nerve localization has been performed previously using guide wires and surgical dyes, the authors' approach using ultrasound-guided instrument clamps helps guide surgical dissection to the target nerve, which could lead to more timely operations and shorter incisions. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Design of a Closed-Loop, Bidirectional Brain Machine Interface System With Energy Efficient Neural Feature Extraction and PID Control.

    Science.gov (United States)

    Liu, Xilin; Zhang, Milin; Richardson, Andrew G; Lucas, Timothy H; Van der Spiegel, Jan

    2017-08-01

    This paper presents a bidirectional brain machine interface (BMI) microsystem designed for closed-loop neuroscience research, especially experiments in freely behaving animals. The system-on-chip (SoC) consists of 16-channel neural recording front-ends, neural feature extraction units, 16-channel programmable neural stimulator back-ends, in-channel programmable closed-loop controllers, global analog-digital converters (ADC), and peripheral circuits. The proposed neural feature extraction units includes 1) an ultra low-power neural energy extraction unit enabling a 64-step natural logarithmic domain frequency tuning, and 2) a current-mode action potential (AP) detection unit with time-amplitude window discriminator. A programmable proportional-integral-derivative (PID) controller has been integrated in each channel enabling a various of closed-loop operations. The implemented ADCs include a 10-bit voltage-mode successive approximation register (SAR) ADC for the digitization of the neural feature outputs and/or local field potential (LFP) outputs, and an 8-bit current-mode SAR ADC for the digitization of the action potential outputs. The multi-mode stimulator can be programmed to perform monopolar or bipolar, symmetrical or asymmetrical charge balanced stimulation with a maximum current of 4 mA in an arbitrary channel configuration. The chip has been fabricated in 0.18 μ m CMOS technology, occupying a silicon area of 3.7 mm 2 . The chip dissipates 56 μW/ch on average. General purpose low-power microcontroller with Bluetooth module are integrated in the system to provide wireless link and SoC configuration. Methods, circuit techniques and system topology proposed in this work can be used in a wide range of relevant neurophysiology research, especially closed-loop BMI experiments.

  17. Constructing QCD one-loop amplitudes

    International Nuclear Information System (INIS)

    Forde, D

    2008-01-01

    In the context of constructing one-loop amplitudes using a unitarity bootstrap approach we discuss a general systematic procedure for obtaining the coefficients of the scalar bubble and triangle integral functions of one-loop amplitudes. Coefficients are extracted after examining the behavior of the cut integrand as the unconstrained parameters of a specifically chosen parameterization of the cut loop momentum approach infinity. Measurements of new physics at the forthcoming experimental program at CERN's Large Hadron Collider (LHC) will require a precise understanding of processes at next-to-leading order (NLO). This places increased demands for the computation of new one-loop amplitudes. This in turn has spurred recent developments towards improved calculational techniques. Direct calculations using Feynman diagrams are in general inefficient. Developments of more efficient techniques have usually centered around unitarity techniques [1], where tree amplitudes are effectively 'glued' together to form loops. The most straightforward application of this method, in which the cut loop momentum is in D = 4, allows for the computation of 'cut-constructible' terms only, i.e. (poly)logarithmic containing terms and any related constants. QCD amplitudes contain, in addition to such terms, rational pieces which cannot be derived using such cuts. These 'missing' rational parts can be extracted using cut loop momenta in D = 4-2 (var e psilon). The greater difficulty of such calculations has restricted the application of this approach, although recent developments [3, 4] have provided new promise for this technique. Recently the application of on-shell recursion relations [5] to obtaining the 'missing' rational parts of one-loop processes [6] has provided an alternative very promising solution to this problem. In combination with unitarity methods an 'on-shell bootstrap' approach provides an efficient technique for computing complete one-loop QCD amplitudes [7]. Additionally

  18. Loop-Loop Interactions Regulate KaiA-Stimulated KaiC Phosphorylation in the Cyanobacterial KaiABC Circadian Clock

    Energy Technology Data Exchange (ETDEWEB)

    Egli, Martin [Vanderbilt Univ., Nashville, TN (United States); Pattanayek, Rekha [Vanderbilt Univ., Nashville, TN (United States); Sheehan, Jonathan H. [Vanderbilt Univ., Nashville, TN (United States); Xu, Yao [Vanderbilt Univ., Nashville, TN (United States); Mori, Tetsuya [Vanderbilt Univ., Nashville, TN (United States); Smith, Jarrod A. [Vanderbilt Univ., Nashville, TN (United States); Johnson, Carl H. [Vanderbilt Univ., Nashville, TN (United States)

    2013-01-25

    We found that the Synechococcus elongatus KaiA, KaiB, and KaiC proteins in the presence of ATP generate a post-translational oscillator that runs in a temperature-compensated manner with a period of 24 h. KaiA dimer stimulates phosphorylation of KaiC hexamer at two sites per subunit, T432 and S431, and KaiB dimers antagonize KaiA action and induce KaiC subunit exchange. Neither the mechanism of KaiA-stimulated KaiC phosphorylation nor that of KaiB-mediated KaiC dephosphorylation is understood in detail at present. We demonstrate here that the A422V KaiC mutant sheds light on the former mechanism. It was previously reported that A422V is less sensitive to dark pulse-induced phase resetting and has a reduced amplitude of the KaiC phosphorylation rhythm in vivo. A422 maps to a loop (422-loop) that continues toward the phosphorylation sites. By pulling on the C-terminal peptide of KaiC (A-loop), KaiA removes restraints from the adjacent 422-loop whose increased flexibility indirectly promotes kinase activity. We found in the crystal structure that A422V KaiC lacks phosphorylation at S431 and exhibits a subtle, local conformational change relative to wild-type KaiC. Molecular dynamics simulations indicate higher mobility of the 422-loop in the absence of the A-loop and mobility differences in other areas associated with phosphorylation activity between wild-type and mutant KaiCs. Finally, the A-loop–422-loop relay that informs KaiC phosphorylation sites of KaiA dimer binding propagates to loops from neighboring KaiC subunits, thus providing support for a concerted allosteric mechanism of phosphorylation.

  19. Functional deficits in peripheral nerve mitochondria in rats with paclitaxel- and oxaliplatin-evoked painful peripheral neuropathy

    OpenAIRE

    Zheng, Huaien; Xiao, Wen Hua; Bennett, Gary J.

    2011-01-01

    Cancer chemotherapeutics like paclitaxel and oxaliplatin produce a dose-limiting chronic sensory peripheral neuropathy that is often accompanied by neuropathic pain. The cause of the neuropathy and pain is unknown. In animal models, paclitaxel-evoked and oxaliplatin-evoked painful peripheral neuropathies are accompanied by an increase in the incidence of swollen and vacuolated mitochondria in peripheral nerve axons. It has been proposed that mitochondrial swelling and vacuolation are indicati...

  20. Mini-review: Far peripheral vision.

    Science.gov (United States)

    Simpson, Michael J

    2017-11-01

    The region of far peripheral vision, beyond 60 degrees of visual angle, is important to the evaluation of peripheral dark shadows (negative dysphotopsia) seen by some intraocular lens (IOL) patients. Theoretical calculations show that the limited diameter of an IOL affects ray paths at large angles, leading to a dimming of the main image for small pupils, and to peripheral illumination by light bypassing the IOL for larger pupils. These effects are rarely bothersome, and cataract surgery is highly successful, but there is a need to improve the characterization of far peripheral vision, for both pseudophakic and phakic eyes. Perimetry is the main quantitative test, but the purpose is to evaluate pathologies rather than characterize vision (and object and image regions are no longer uniquely related in the pseudophakic eye). The maximum visual angle is approximately 105 0 , but there is limited information about variations with age, race, or refractive error (in case there is an unexpected link with the development of myopia), or about how clear cornea, iris location, and the limiting retina are related. Also, the detection of peripheral motion is widely recognized to be important, yet rarely evaluated. Overall, people rarely complain specifically about this visual region, but with "normal" vision including an IOL for >5% of people, and increasing interest in virtual reality and augmented reality, there are new reasons to characterize peripheral vision more completely. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Two-phase Heating in Flaring Loops

    Science.gov (United States)

    Zhu, Chunming; Qiu, Jiong; Longcope, Dana W.

    2018-03-01

    We analyze and model a C5.7 two-ribbon solar flare observed by the Solar Dynamics Observatory, Hinode, and GOES on 2011 December 26. The flare is made of many loops formed and heated successively over one and half hours, and their footpoints are brightened in the UV 1600 Å before enhanced soft X-ray and EUV missions are observed in flare loops. Assuming that anchored at each brightened UV pixel is a half flaring loop, we identify more than 6700 half flaring loops, and infer the heating rate of each loop from the UV light curve at the footpoint. In each half loop, the heating rate consists of two phases: intense impulsive heating followed by a low-rate heating that is persistent for more than 20 minutes. Using these heating rates, we simulate the evolution of their coronal temperatures and densities with the model of the “enthalpy-based thermal evolution of loops.” In the model, suppression of thermal conduction is also considered. This model successfully reproduces total soft X-ray and EUV light curves observed in 15 passbands by four instruments GOES, AIA, XRT, and EVE. In this flare, a total energy of 4.9 × 1030 erg is required to heat the corona, around 40% of this energy is in the slow-heating phase. About two-fifths of the total energy used to heat the corona is radiated by the coronal plasmas, and the other three fifth transported to the lower atmosphere by thermal conduction.

  2. Control-structure interaction in precision pointing servo loops

    Science.gov (United States)

    Spanos, John T.

    1989-01-01

    The control-structure interaction problem is addressed via stability analysis of a generic linear servo loop model. With the plant described by the rigid body mode and a single elastic mode, structural flexibility is categorized into one of three types: (1) appendage, (2) in-the-loop minimum phase, and (3) in-the-loop nonminimum phase. Closing the loop with proportional-derivative (PD) control action and introducing sensor roll-off dynamics in the feedback path, stability conditions are obtained. Trade studies are conducted with modal frequency, modal participation, modal damping, loop bandwidth, and sensor bandwidth treated as free parameters. Results indicate that appendage modes are most likely to produce instability if they are near the sensor rolloff, whereas in-the-loop modes are most dangerous near the loop bandwidth. The main goal of this paper is to provide a fundamental understanding of the control-structure interaction problem so that it may benefit the design of complex spacecraft and pointing system servo loops. In this framework, the JPL Pathfinder gimbal pointer is considered as an example.

  3. Numerical evaluation of one-loop QCD amplitudes

    DEFF Research Database (Denmark)

    Badger, Simon David; Biedermann, Benedikt; Uwer, Peter

    2012-01-01

    We present the publicly available program NGluon allowing the numerical evaluation of primitive amplitudes at one-loop order in massless QCD. The program allows the computation of one-loop amplitudes for an arbitrary number of gluons. The focus of the present article is the extension to one-loop ...

  4. Vertically Polarized Omnidirectional Printed Slot Loop Antenna

    DEFF Research Database (Denmark)

    Kammersgaard, Nikolaj Peter Iversen; Kvist, Søren H.; Thaysen, Jesper

    2015-01-01

    A novel vertically polarized omnidirectional printed slot loop antenna has been designed, simulated, fabricated and measured. The slot loop works as a magnetic loop. The loop is loaded with inductors to insure uniform and in-phase fields in the slot in order to obtain an omnidirectional radiation...... pattern. The antenna is designed for the 2.45 GHz Industrial, Scientific and Medical band. Applications of the antenna are many. One is for on-body applications since it is ideal for launching a creeping waves due to the polarization....

  5. String breaking with Wilson loops?

    CERN Document Server

    Kratochvila, S; Kratochvila, Slavo; Forcrand, Philippe de

    2003-01-01

    A convincing, uncontroversial observation of string breaking, when the static potential is extracted from Wilson loops only, is still missing. This failure can be understood if the overlap of the Wilson loop with the broken string is exponentially small. In that case, the broken string ground state will only be seen if the Wilson loop is long enough. Our preliminary results show string breaking in the context of the 3d SU(2) adjoint static potential, using the L\\"uscher-Weisz exponential variance reduction approach. As a by-product, we measure the fundamental SU(2) static potential with improved accuracy and see clear deviations from Casimir scaling.

  6. BMN correlators by loop equations

    International Nuclear Information System (INIS)

    Eynard, Bertrand; Kristjansen, Charlotte

    2002-01-01

    In the BMN approach to N=4 SYM a large class of correlators of interest are expressible in terms of expectation values of traces of words in a zero-dimensional gaussian complex matrix model. We develop a loop-equation based, analytic strategy for evaluating such expectation values to any order in the genus expansion. We reproduce the expectation values which were needed for the calculation of the one-loop, genus one correction to the anomalous dimension of BMN-operators and which were earlier obtained by combinatorial means. Furthermore, we present the expectation values needed for the calculation of the one-loop, genus two correction. (author)

  7. Loop-space quantum formulation of free electromagnetism

    International Nuclear Information System (INIS)

    Di Bartolo, C.; Nori, F.; Gambini, R.; Trias, A.

    1983-01-01

    A procedure for direct quantization of free electromagnetism in the loop-space is proposed. Explicit solutions for the loop-dependent vacuum and the Wilson loop-average are given. It is shown that elementary lines of magnetic field appear as extremals in the vacuum state as a result of the regularization procedure

  8. A totally diverting loop colostomy.

    Science.gov (United States)

    Merrett, N. D.; Gartell, P. C.

    1993-01-01

    A technique is described where the distal limb of a loop colostomy is tied with nylon or polydioxanone. This ensures total faecal diversion and dispenses with the supporting rod, enabling early application of stoma appliances. The technique does not interfere with the traditional transverse closure of a loop colostomy. PMID:8379632

  9. Tyrosine B10 triggers a heme propionate hydrogen bonding network loop with glutamine E7 moiety

    International Nuclear Information System (INIS)

    Ramos-Santana, Brenda J.; López-Garriga, Juan

    2012-01-01

    Highlights: ► H-bonding network loop by PheB10Tyr mutation is proposed. ► The propionate group H-bonding network restricted the flexibility of the heme. ► The hydrogen bonding interaction modulates the electron density of the iron. ► Propionate H-bonding network loop explains the heme-ligand stabilization. -- Abstract: Propionates, as peripheral groups of the heme active center in hemeproteins have been described to contribute in the modulation of heme reactivity and ligand selection. These electronic characteristics prompted the question of whether the presence of hydrogen bonding networks between propionates and distal amino acids present in the heme ligand moiety can modulate physiological relevant events, like ligand binding association and dissociation activities. Here, the role of these networks was evaluated by NMR spectroscopy using the hemoglobin I PheB10Tyr mutant from Lucina pectinata as model for TyrB10 and GlnE7 hemeproteins. 1 H-NMR results for the rHbICN PheB10Tyr derivative showed chemical shifts of TyrB10 OHη at 31.00 ppm, GlnE7 N ε1 H/N ε2 H at 10.66 ppm/−3.27 ppm, and PheE11 C δ H at 11.75 ppm, indicating the presence of a crowded, collapsed, and constrained distal pocket. Strong dipolar contacts and inter-residues crosspeaks between GlnE7/6-propionate group, GlnE7/TyrB10 and TyrB10/CN suggest that this hydrogen bonding network loop between GlnE7, TyrB10, 6-propionate group, and the heme ligand contribute significantly to the modulation of the heme iron electron density as well as the ligand stabilization mechanism. Therefore, the network loop presented here support the fact that the electron withdrawing character of the hydrogen bonding is controlled by the interaction of the propionates and the nearby electronic environments contributing to the modulation of the heme electron density state. Thus, we hypothesize that in hemeproteins with similar electrostatic environment the flexibility of the heme-6-propionate promotes a hydrogen

  10. Long term clinical outcome of peripheral nerve stimulation in patients with chronic peripheral neuropathic pain

    DEFF Research Database (Denmark)

    Calenbergh, F. Van; Gybels, J.; Laere, K. Van

    2009-01-01

    BACKGROUND: Chronic neuropathic pain after injury to a peripheral nerve is known to be resistant to treatment. Peripheral nerve stimulation is one of the possible treatment options, which is, however, not performed frequently. In recent years we have witnessed a renewed interest for PNS. The aim...... of the present study was to evaluate the long-term clinical efficacy of PNS in a group of patients with peripheral neuropathic pain treated with PNS since the 1980s. METHODS: Of an original series of 11 patients, 5 patients could be invited for clinical examination, detailed assessment of clinical pain and QST...... functioning) also showed positive effects. Quantitative Sensory Testing results did not show significant differences in cold pain and heat pain thresholds between the "ON" and "OFF" conditions. CONCLUSION: In selected patients with peripheral neuropathic pain PNS remains effective even after more than 20...

  11. On-the-fly reduction of open loops

    Energy Technology Data Exchange (ETDEWEB)

    Buccioni, Federico; Pozzorini, Stefano; Zoller, Max [Universitaet Zuerich, Physik-Institut, Zurich (Switzerland)

    2018-01-15

    Building on the open-loop algorithm we introduce a new method for the automated construction of one-loop amplitudes and their reduction to scalar integrals. The key idea is that the factorisation of one-loop integrands in a product of loop segments makes it possible to perform various operations on-the-fly while constructing the integrand. Reducing the integrand on-the-fly, after each segment multiplication, the construction of loop diagrams and their reduction are unified in a single numerical recursion. In this way we entirely avoid objects with high tensor rank, thereby reducing the complexity of the calculations in a drastic way. Thanks to the on-the-fly approach, which is applied also to helicity summation and for the merging of different diagrams, the speed of the original open-loop algorithm can be further augmented in a very significant way. Moreover, addressing spurious singularities of the employed reduction identities by means of simple expansions in rank-two Gram determinants, we achieve a remarkably high level of numerical stability. These features of the new algorithm, which will be made publicly available in a forthcoming release of the OpenLoops program, are particularly attractive for NLO multi-leg and NNLO real-virtual calculations. (orig.)

  12. On-the-fly reduction of open loops

    Science.gov (United States)

    Buccioni, Federico; Pozzorini, Stefano; Zoller, Max

    2018-01-01

    Building on the open-loop algorithm we introduce a new method for the automated construction of one-loop amplitudes and their reduction to scalar integrals. The key idea is that the factorisation of one-loop integrands in a product of loop segments makes it possible to perform various operations on-the-fly while constructing the integrand. Reducing the integrand on-the-fly, after each segment multiplication, the construction of loop diagrams and their reduction are unified in a single numerical recursion. In this way we entirely avoid objects with high tensor rank, thereby reducing the complexity of the calculations in a drastic way. Thanks to the on-the-fly approach, which is applied also to helicity summation and for the merging of different diagrams, the speed of the original open-loop algorithm can be further augmented in a very significant way. Moreover, addressing spurious singularities of the employed reduction identities by means of simple expansions in rank-two Gram determinants, we achieve a remarkably high level of numerical stability. These features of the new algorithm, which will be made publicly available in a forthcoming release of the OpenLoops program, are particularly attractive for NLO multi-leg and NNLO real-virtual calculations.

  13. Loop Quantum Cosmology.

    Science.gov (United States)

    Bojowald, Martin

    2008-01-01

    Quantum gravity is expected to be necessary in order to understand situations in which classical general relativity breaks down. In particular in cosmology one has to deal with initial singularities, i.e., the fact that the backward evolution of a classical spacetime inevitably comes to an end after a finite amount of proper time. This presents a breakdown of the classical picture and requires an extended theory for a meaningful description. Since small length scales and high curvatures are involved, quantum effects must play a role. Not only the singularity itself but also the surrounding spacetime is then modified. One particular theory is loop quantum cosmology, an application of loop quantum gravity to homogeneous systems, which removes classical singularities. Its implications can be studied at different levels. The main effects are introduced into effective classical equations, which allow one to avoid the interpretational problems of quantum theory. They give rise to new kinds of early-universe phenomenology with applications to inflation and cyclic models. To resolve classical singularities and to understand the structure of geometry around them, the quantum description is necessary. Classical evolution is then replaced by a difference equation for a wave function, which allows an extension of quantum spacetime beyond classical singularities. One main question is how these homogeneous scenarios are related to full loop quantum gravity, which can be dealt with at the level of distributional symmetric states. Finally, the new structure of spacetime arising in loop quantum gravity and its application to cosmology sheds light on more general issues, such as the nature of time. Supplementary material is available for this article at 10.12942/lrr-2008-4.

  14. Hydraulic loop: practices using open control systems

    International Nuclear Information System (INIS)

    Carrasco, J.A.; Alonso, L.; Sanchez, F.

    1998-01-01

    The Tecnatom Hydraulic Loop is a dynamic training platform. It has been designed with the purpose of improving the work in teams. With this system, the student can obtain a full scope vision of a system. The hydraulic Loop is a part of the Tecnatom Maintenance Centre. The first objective of the hydraulic Loop is the instruction in components, process and process control using open control system. All the personal of an electric power plant can be trained in the Hydraulic Loop with specific courses. The development of a dynamic tool for tests previous to plant installations has been an additional objective of the Hydraulic Loop. The use of this platform is complementary to the use of full-scope simulators in order to debug and to analyse advanced control strategies. (Author)

  15. Osmotic mechanism of the loop extrusion process

    Science.gov (United States)

    Yamamoto, Tetsuya; Schiessel, Helmut

    2017-09-01

    The loop extrusion theory assumes that protein factors, such as cohesin rings, act as molecular motors that extrude chromatin loops. However, recent single molecule experiments have shown that cohesin does not show motor activity. To predict the physical mechanism involved in loop extrusion, we here theoretically analyze the dynamics of cohesin rings on a loop, where a cohesin loader is in the middle and unloaders at the ends. Cohesin monomers bind to the loader rather frequently and cohesin dimers bind to this site only occasionally. Our theory predicts that a cohesin dimer extrudes loops by the osmotic pressure of cohesin monomers on the chromatin fiber between the two connected rings. With this mechanism, the frequency of the interactions between chromatin segments depends on the loading and unloading rates of dimers at the corresponding sites.

  16. Two-Loop Scattering Amplitudes from the Riemann Sphere

    CERN Document Server

    Geyer, Yvonne; Monteiro, Ricardo; Tourkine, Piotr

    2016-01-01

    The scattering equations give striking formulae for massless scattering amplitudes at tree level and, as shown recently, at one loop. The progress at loop level was based on ambitwistor string theory, which naturally yields the scattering equations. We proposed that, for ambitwistor strings, the standard loop expansion in terms of the genus of the worldsheet is equivalent to an expansion in terms of nodes of a Riemann sphere, with the nodes carrying the loop momenta. In this paper, we show how to obtain two-loop scattering equations with the correct factorization properties. We adapt genus-two integrands from the ambitwistor string to the nodal Riemann sphere and show that these yield correct answers, by matching standard results for the four-point two-loop amplitudes of maximal supergravity and super-Yang-Mills theory. In the Yang-Mills case, this requires the loop analogue of the Parke-Taylor factor carrying the colour dependence, which includes non-planar contributions.

  17. Free convection in a partially submerged fluid loop

    International Nuclear Information System (INIS)

    Britt, T.E.; Wood, D.C.

    1982-01-01

    Several natural convection loop systems are studied in order to determine the operational characteristics for a multiple loop container which is used to cool failed nuclear reactor assemblies. Both analytical and experimental studies were undertaken to examine flow in both circular and rectangular flow loops. It was found that when a circular loop is heated at the bottom and cooled at the top, recirculation cells form at all input power fluxes. At fluxes between 0.1 W/cm 2 and 0.7 W/cm 2 the cells caused flow oscillations and reversals. With the circular loop heated from the side, no recirculation cells were observed at the power fluxes up to 1.5 W/cm. Boiling did not occur in the circular loop. For a rectangular loop heated and cooled on its vertical sides, no recirculation cells or flow reversals were seen. At input power fluxes above 1.2 W/cm 2 , periodic boiling in the heated side caused flow oscillations

  18. Cooling Active Region Loops Observed With SXT and TRACE

    OpenAIRE

    Winebarger, Amy R.; Warren, Harry P.

    2005-01-01

    An Impulsive Heating Multiple Strand (IHMS) Model is able to reproduce the observational characteristics of EUV (~ 1 MK) active region loops. This model implies that some of the loops must reach temperatures where X-ray filters are sensitive (> 2.5 MK) before they cool to EUV temperatures. Hence, some bright EUV loops must be preceded by bright X-ray loops. Previous analysis of X-ray and EUV active region observations, however, have concluded that EUV loops are not preceded by X-ray loops. In...

  19. Quantum chromodynamics as dynamics of loops

    International Nuclear Information System (INIS)

    Makeenko, Yu.M.; Migdal, A.A.

    1981-01-01

    QCD is entirely reformulated in terms of white composite fields - the traces of the loop products. The 1/N expansion turns out to be the WKB (Hartree-Fock) approximation for these fields. The 'classical' equation describing the N = infinite case is reduced tp a bootstrap form. New, manifestly gauge-invariant perturbation theory in the loop space, reproducing asymptotic freedom, is developed by iterations of this equation. The area law appears to be a self-consistent solution at large loops. (orig.)

  20. Closed Loop Deep Brain Stimulation for PTSD, Addiction, and Disorders of Affective Facial Interpretation: Review and Discussion of Potential Biomarkers and Stimulation Paradigms

    Directory of Open Access Journals (Sweden)

    Robert W. Bina

    2018-05-01

    Full Text Available The treatment of psychiatric diseases with Deep Brain Stimulation (DBS is becoming more of a reality as studies proliferate the indications and targets for therapies. Opinions on the initial failures of DBS trials for some psychiatric diseases point to a certain lack of finesse in using an Open Loop DBS (OLDBS system in these dynamic, cyclical pathologies. OLDBS delivers monomorphic input into dysfunctional brain circuits with modulation of that input via human interface at discrete time points with no interim modulation or adaptation to the changing circuit dynamics. Closed Loop DBS (CLDBS promises dynamic, intrinsic circuit modulation based on individual physiologic biomarkers of dysfunction. Discussed here are several psychiatric diseases which may be amenable to CLDBS paradigms as the neurophysiologic dysfunction is stochastic and not static. Post-Traumatic Stress Disorder (PTSD has several peripheral and central physiologic and neurologic changes preceding stereotyped hyper-activation behavioral responses. Biomarkers for CLDBS potentially include skin conductance changes indicating changes in the sympathetic nervous system, changes in serum and central neurotransmitter concentrations, and limbic circuit activation. Chemical dependency and addiction have been demonstrated to be improved with both ablation and DBS of the Nucleus Accumbens and as a serendipitous side effect of movement disorder treatment. Potential peripheral biomarkers are similar to those proposed for PTSD with possible use of environmental and geolocation based cues, peripheral signs of physiologic arousal, and individual changes in central circuit patterns. Non-substance addiction disorders have also been serendipitously treated in patients with OLDBS for movement disorders. As more is learned about these behavioral addictions, DBS targets and effectors will be identified. Finally, discussed is the use of facial recognition software to modulate activation of inappropriate

  1. The Universal One-Loop Effective Action

    CERN Document Server

    Drozd, Aleksandra; Quevillon, Jérémie; You, Tevong

    2016-01-01

    We present the universal one-loop effective action for all operators of dimension up to six obtained by integrating out massive, non-degenerate multiplets. Our general expression may be applied to loops of heavy fermions or bosons, and has been checked against partial results available in the literature. The broad applicability of this approach simplifies one-loop matching from an ultraviolet model to a lower-energy effective field theory (EFT), a procedure which is now reduced to the evaluation of a combination of matrices in our universal expression, without any loop integrals to evaluate. We illustrate the relationship of our results to the Standard Model (SM) EFT, using as an example the supersymmetric stop and sbottom squark Lagrangian and extracting from our universal expression the Wilson coefficients of dimension-six operators composed of SM fields.

  2. The universal one-loop effective action

    International Nuclear Information System (INIS)

    Drozd, Aleksandra; Ellis, John; Quevillon, Jérémie; You, Tevong

    2016-01-01

    We present the universal one-loop effective action for all operators of dimension up to six obtained by integrating out massive, non-degenerate multiplets. Our general expression may be applied to loops of heavy fermions or bosons, and has been checked against partial results available in the literature. The broad applicability of this approach simplifies one-loop matching from an ultraviolet model to a lower-energy effective field theory (EFT), a procedure which is now reduced to the evaluation of a combination of matrices in our universal expression, without any loop integrals to evaluate. We illustrate the relationship of our results to the Standard Model (SM) EFT, using as an example the supersymmetric stop and sbottom squark Lagrangian and extracting from our universal expression the Wilson coefficients of dimension-six operators composed of SM fields.

  3. Mathematical Modeling of Loop Heat Pipes

    Science.gov (United States)

    Kaya, Tarik; Ku, Jentung; Hoang, Triem T.; Cheung, Mark L.

    1998-01-01

    The primary focus of this study is to model steady-state performance of a Loop Heat Pipe (LHP). The mathematical model is based on the steady-state energy balance equations at each component of the LHP. The heat exchange between each LHP component and the surrounding is taken into account. Both convection and radiation environments are modeled. The loop operating temperature is calculated as a function of the applied power at a given loop condition. Experimental validation of the model is attempted by using two different LHP designs. The mathematical model is tested at different sink temperatures and at different elevations of the loop. Tbc comparison of the calculations and experimental results showed very good agreement (within 3%). This method proved to be a useful tool in studying steady-state LHP performance characteristics.

  4. Loop expansion in massless three-dimensional QED

    International Nuclear Information System (INIS)

    Guendelman, E.I.; Radulovic, Z.M.

    1983-01-01

    It is shown how the loop expansion in massless three-dimensional QED can be made finite, up to three loops, by absorbing the infrared divergences in a gauge-fixing term. The same method removes leading and first subleading singularities to all orders of perturbation theory, and all singularities of the fermion self-energy to four loops

  5. Normal and sonographic anatomy of selected peripheral nerves. Part III: Peripheral nerves of the lower limb.

    Science.gov (United States)

    Kowalska, Berta; Sudoł-Szopińska, Iwona

    2012-06-01

    The ultrasonographic examination is currently increasingly used in imaging peripheral nerves, serving to supplement the physical examination, electromyography and magnetic resonance imaging. As in the case of other USG imaging studies, the examination of peripheral nerves is non-invasive and well-tolerated by patients. The typical ultrasonographic picture of peripheral nerves as well as the examination technique have been discussed in part I of this article series, following the example of the median nerve. Part II of the series presented the normal anatomy and the technique for examining the peripheral nerves of the upper limb. This part of the article series focuses on the anatomy and technique for examining twelve normal peripheral nerves of the lower extremity: the iliohypogastric and ilioinguinal nerves, the lateral cutaneous nerve of the thigh, the pudendal, sciatic, tibial, sural, medial plantar, lateral plantar, common peroneal, deep peroneal and superficial peroneal nerves. It includes diagrams showing the proper positioning of the sonographic probe, plus USG images of the successively discussed nerves and their surrounding structures. The ultrasonographic appearance of the peripheral nerves in the lower limb is identical to the nerves in the upper limb. However, when imaging the lower extremity, convex probes are more often utilized, to capture deeply-seated nerves. The examination technique, similarly to that used in visualizing the nerves of upper extremity, consists of locating the nerve at a characteristic anatomic reference point and tracking it using the "elevator technique". All 3 parts of the article series should serve as an introduction to a discussion of peripheral nerve pathologies, which will be presented in subsequent issues of the "Journal of Ultrasonography".

  6. Treatment of painful diabetic peripheral neuropathy.

    Science.gov (United States)

    Rosenberg, Casandra J; Watson, James C

    2015-02-01

    Painful diabetic peripheral neuropathy impairs quality of life and can be difficult to treat. To discuss current treatment recommendations for painful diabetic peripheral neuropathy. Literature review. Systematic review of the literature discussing treatment of painful diabetic peripheral neuropathy. Existing treatment guidelines were studied and compared. Painful diabetic peripheral neuropathy occurs in about one in six people with diabetes. This condition impairs quality of life and increases healthcare costs. Treatment recommendations exist, but individual patient therapy can require a trial-and-error approach. Many treatment options have adjuvant benefits or side effects which should be considered prior to initiating therapy. Often, a combination of treatment modalities with various mechanisms of action is required for adequate pain control. Adequate medication titration and a reasonable trial period should be allowed. The treatment of painful diabetic peripheral neuropathy can be challenging, but effective management can improve patient's quality of life. Painful diabetic peripheral neuropathy impairs quality of life and can be difficult to treat. Many treatment options have adjuvant benefits or side effects which should be considered prior to initiating therapy. Often, a combination of treatment modalities with various mechanisms of action is required for adequate pain control. © The International Society for Prosthetics and Orthotics 2014.

  7. A LabVIEW model incorporating an open-loop arterial impedance and a closed-loop circulatory system.

    Science.gov (United States)

    Cole, R T; Lucas, C L; Cascio, W E; Johnson, T A

    2005-11-01

    While numerous computer models exist for the circulatory system, many are limited in scope, contain unwanted features or incorporate complex components specific to unique experimental situations. Our purpose was to develop a basic, yet multifaceted, computer model of the left heart and systemic circulation in LabVIEW having universal appeal without sacrificing crucial physiologic features. The program we developed employs Windkessel-type impedance models in several open-loop configurations and a closed-loop model coupling a lumped impedance and ventricular pressure source. The open-loop impedance models demonstrate afterload effects on arbitrary aortic pressure/flow inputs. The closed-loop model catalogs the major circulatory waveforms with changes in afterload, preload, and left heart properties. Our model provides an avenue for expanding the use of the ventricular equations through closed-loop coupling that includes a basic coronary circuit. Tested values used for the afterload components and the effects of afterload parameter changes on various waveforms are consistent with published data. We conclude that this model offers the ability to alter several circulatory factors and digitally catalog the most salient features of the pressure/flow waveforms employing a user-friendly platform. These features make the model a useful instructional tool for students as well as a simple experimental tool for cardiovascular research.

  8. Promoting peripheral myelin repair.

    Science.gov (United States)

    Zhou, Ye; Notterpek, Lucia

    2016-09-01

    Compared to the central nervous system (CNS), peripheral nerves have a remarkable ability to regenerate and remyelinate. This regenerative capacity to a large extent is dependent on and supported by Schwann cells, the myelin-forming glial cells of the peripheral nervous system (PNS). In a variety of paradigms, Schwann cells are critical in the removal of the degenerated tissue, which is followed by remyelination of newly-regenerated axons. This unique plasticity of Schwann cells has been the target of myelin repair strategies in acute injuries and chronic diseases, such as hereditary demyelinating neuropathies. In one approach, the endogenous regenerative capacity of Schwann cells is enhanced through interventions such as exercise, electrical stimulation or pharmacological means. Alternatively, Schwann cells derived from healthy nerves, or engineered from different tissue sources have been transplanted into the PNS to support remyelination. These transplant approaches can then be further enhanced by exercise and/or electrical stimulation, as well as by the inclusion of biomaterial engineered to support glial cell viability and neurite extension. Advances in our basic understanding of peripheral nerve biology, as well as biomaterial engineering, will further improve the functional repair of myelinated peripheral nerves. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Peripheral neuropathy in HIV: prevalence and risk factors

    Science.gov (United States)

    Evans, Scott R.; Ellis, Ronald J.; Chen, Huichao; Yeh, Tzu-min; Lee, Anthony J.; Schifitto, Giovanni; Wu, Kunling; Bosch, Ronald J.; McArthur, Justin C.; Simpson, David M.; Clifford, David B.

    2011-01-01

    Objectives To estimate neuropathic sign/symptom rates with initiation of combination antiretroviral therapy (cART) in HIV-infected ART-naive patients, and to investigate risk factors for: peripheral neuropathy and symptomatic peripheral neuropathy (SPN), recovery from peripheral neuropathy/SPN after neurotoxic ART (nART) discontinuation, and the absence of peripheral neuropathy/SPN while on nART. Design AIDS Clinical Trials Group (ACTG) Longitudinal Linked Randomized Trial participants who initiated cART in randomized trials for ART-naive patients were annually screened for symptoms/signs of peripheral neuropathy. ART use and disease characteristics were collected longitudinally. Methods Peripheral neuropathy was defined as at least mild loss of vibration sensation in both great toes or absent/hypoactive ankle reflexes bilaterally. SPN was defined as peripheral neuropathy and bilateral symptoms. Generalized estimating equation logistic regression was used to estimate associations. Results Two thousand, one hundred and forty-one participants were followed from January 2000 to June 2007. Rates of peripheral neuropathy/SPN at 3 years were 32.1/8.6% despite 87.1% with HIV-1RNA 400 copies/ml or less and 70.3% with CD4 greater than 350 cells/µl. Associations with higher odds of peripheral neuropathy included older patient age and current nART use. Associations with higher odds of SPN included older patient age, nART use, and history of diabetes mellitus. Associations with lower odds of recovery after nART discontinuation included older patient age. Associations with higher odds of peripheral neuropathy while on nART included older patient age and current protease inhibitor use. Associations with higher odds of SPN while on nART included older patient age, history of diabetes, taller height, and protease inhibitor use. Conclusion Signs of peripheral neuropathy remain despite virologic/immunologic control but frequently occurs without symptoms. Aging is a risk factor for

  10. Mechanical evaluation of space closure loops in orthodontics.

    Science.gov (United States)

    Rodrigues, Eduardo Uggeri; Maruo, Hiroshi; Guariza Filho, Odilon; Tanaka, Orlando; Camargo, Elisa Souza

    2011-01-01

    This study evaluated the mechanical performance of teardrop-shaped loops and teardrop-shaped loops with helix used in orthodontic space closure. Sixty retraction loops made with 0.019" x 0.025" stainless steel (SS) and beta-titanium (BT) wires were used. They were attached to a testing machine to measure the magnitudes of the sagittal force and the load-deflection ratio necessary for 1 mm, 2 mm and 3 mm activation. The results demonstrated that the BT alloy presented significantly smaller mean values (p < 0.01) of sagittal force and load-deflection than the SS alloy. The loop with the highest mean value of sagittal force and load-deflection was the teardrop-shaped loop (p < 0.01). Differences were observed in the mean values of sagittal force and load-deflection among activations, and the highest mean value was found in the activation of 3 mm, while the smallest mean value was evident in the activation of 1 mm (p < 0.01). It could be concluded that the metallic alloy used and the presence of a helix in configuration of the loops may have a strong influence on the sagittal force produced and on the load-deflection ratio; the teardrop-shaped loops and teardrop-shaped loops with helix in BT presented the release of lighter forces; the teardrop-shaped loop in SS generated a high load-deflection ratio, providing high magnitudes of horizontal force during its deactivation.

  11. Mechanical evaluation of space closure loops in Orthodontics

    Directory of Open Access Journals (Sweden)

    Eduardo Uggeri Rodrigues

    2011-02-01

    Full Text Available This study evaluated the mechanical performance of teardrop-shaped loops and teardrop-shaped loops with helix used in orthodontic space closure. Sixty retraction loops made with 0.019" x 0.025" stainless steel (SS and beta-titanium (BT wires were used. They were attached to a testing machine to measure the magnitudes of the sagittal force and the load-deflection ratio necessary for 1 mm, 2 mm and 3 mm activation. The results demonstrated that the BT alloy presented significantly smaller mean values (p < 0.01 of sagittal force and load-deflection than the SS alloy. The loop with the highest mean value of sagittal force and load-deflection was the teardrop-shaped loop (p < 0.01. Differences were observed in the mean values of sagittal force and load-deflection among activations, and the highest mean value was found in the activation of 3 mm, while the smallest mean value was evident in the activation of 1 mm (p < 0.01. It could be concluded that the metallic alloy used and the presence of a helix in configuration of the loops may have a strong influence on the sagittal force produced and on the load-deflection ratio; the teardrop-shaped loops and teardrop-shaped loops with helix in BT presented the release of lighter forces; the teardrop-shaped loop in SS generated a high load-deflection ratio, providing high magnitudes of horizontal force during its deactivation.

  12. Protein Loop Structure Prediction Using Conformational Space Annealing.

    Science.gov (United States)

    Heo, Seungryong; Lee, Juyong; Joo, Keehyoung; Shin, Hang-Cheol; Lee, Jooyoung

    2017-05-22

    We have developed a protein loop structure prediction method by combining a new energy function, which we call E PLM (energy for protein loop modeling), with the conformational space annealing (CSA) global optimization algorithm. The energy function includes stereochemistry, dynamic fragment assembly, distance-scaled finite ideal gas reference (DFIRE), and generalized orientation- and distance-dependent terms. For the conformational search of loop structures, we used the CSA algorithm, which has been quite successful in dealing with various hard global optimization problems. We assessed the performance of E PLM with two widely used loop-decoy sets, Jacobson and RAPPER, and compared the results against the DFIRE potential. The accuracy of model selection from a pool of loop decoys as well as de novo loop modeling starting from randomly generated structures was examined separately. For the selection of a nativelike structure from a decoy set, E PLM was more accurate than DFIRE in the case of the Jacobson set and had similar accuracy in the case of the RAPPER set. In terms of sampling more nativelike loop structures, E PLM outperformed E DFIRE for both decoy sets. This new approach equipped with E PLM and CSA can serve as the state-of-the-art de novo loop modeling method.

  13. Effect of Loop Diameter on the Steady State and Stability Behaviour of Single-Phase and Two-Phase Natural Circulation Loops

    Directory of Open Access Journals (Sweden)

    P. K. Vijayan

    2008-01-01

    Full Text Available In natural circulation loops, the driving force is usually low as it depends on the riser height which is generally of the order of a few meters. The heat transport capability of natural circulation loops (NCLs is directly proportional to the flow rate it can generate. With low driving force, the straightforward way to enhance the flow is to reduce the frictional losses. A simple way to do this is to increase the loop diameter which can be easily adopted in pressure tube designs such as the AHWR and the natural circulation boilers employed in fossil-fuelled power plants. Further, the loop diameter also plays an important role on the stability behavior. An extensive experimental and theoretical investigation of the effect of loop diameter on the steady state and stability behavior of single- and two-phase natural circulation loops have been carried out and the results of this study are presented in this paper.

  14. UPTF loop seal tests and their RELAP simulation

    International Nuclear Information System (INIS)

    Tuomainen, M.; Tuunanen, J.

    1997-01-01

    In a pressurized water reactor the loop seals have an effect on the natural circulation. If a loop seal is filled with water it can cause a flow stagnation in the loop during two-phase natural circulation. Also the pressure loss over a filled loop seal is high, which lowers the water level in the core. Tests to investigate the loop seal behaviour were performed on a German Upper Plenum Test Facility (UPTF). The purpose of the tests was to study the amount of water in the loop seal under different steam flow rates. The tests were simulated with RELAP5/MOD3.2. With high steam flow rates the code had problems in simulating the amount of the water remaining in the pump elbow, but in general the agreement between the calculated results and the experimental data was good. (orig.)

  15. Peripheral Vestibular System Disease in Vestibular Schwannomas

    DEFF Research Database (Denmark)

    Møller, Martin Nue; Hansen, Søren; Caye-Thomasen, Per

    2015-01-01

    density of the peripheral vestibular nerve branches, and atrophy of the neuroepithelium of the vestibular end organs. In cases with small tumors, peripheral disease occurred only in the tissue structures innervated by the specific nerve from which the tumor originated. CONCLUSION: Vestibular schwannomas...... are associated with distinctive disease of the peripheral vestibular tissue structures, suggesting anterograde degeneration and that dizziness in these patients may be caused by deficient peripheral vestibular nerve fibers, neurons, and end organs. In smaller tumors, a highly localized disease occurs, which...

  16. SU(2) string tension from large Wilson loops

    International Nuclear Information System (INIS)

    Karsch, F.; Lang, C.B.

    1984-01-01

    We determine expectation values of Wilson loops and correlations of Polyakov loops on lattices of size 10 X 16 3 and 8 X 16 3 at β values 2.25 and 2.375. Utilizing a recently proposed method to reduce the variance of loop expectation values, we are able to measure loops up to 6 X 6. We find Λsub(L) = 0.0151 +- 0.0006√sub(K) at β = 2.375. (orig.)

  17. Incremental Closed-loop Identification of Linear Parameter Varying Systems

    DEFF Research Database (Denmark)

    Bendtsen, Jan Dimon; Trangbæk, Klaus

    2011-01-01

    , closed-loop system identification is more difficult than open-loop identification. In this paper we prove that the so-called Hansen Scheme, a technique known from linear time-invariant systems theory for transforming closed-loop system identification problems into open-loop-like problems, can be extended...

  18. Studying DNA looping by single-molecule FRET.

    Science.gov (United States)

    Le, Tung T; Kim, Harold D

    2014-06-28

    Bending of double-stranded DNA (dsDNA) is associated with many important biological processes such as DNA-protein recognition and DNA packaging into nucleosomes. Thermodynamics of dsDNA bending has been studied by a method called cyclization which relies on DNA ligase to covalently join short sticky ends of a dsDNA. However, ligation efficiency can be affected by many factors that are not related to dsDNA looping such as the DNA structure surrounding the joined sticky ends, and ligase can also affect the apparent looping rate through mechanisms such as nonspecific binding. Here, we show how to measure dsDNA looping kinetics without ligase by detecting transient DNA loop formation by FRET (Fluorescence Resonance Energy Transfer). dsDNA molecules are constructed using a simple PCR-based protocol with a FRET pair and a biotin linker. The looping probability density known as the J factor is extracted from the looping rate and the annealing rate between two disconnected sticky ends. By testing two dsDNAs with different intrinsic curvatures, we show that the J factor is sensitive to the intrinsic shape of the dsDNA.

  19. Process/Equipment Co-Simulation on Syngas Chemical Looping Process

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Liang; Zhou, Qiang; Fan, Liang-Shih

    2012-09-30

    The chemical looping strategy for fossil energy applications promises to achieve an efficient energy conversion system for electricity, liquid fuels, hydrogen and/or chemicals generation, while economically separate CO{sub 2} by looping reaction design in the process. Chemical looping particle performance, looping reactor engineering, and process design and applications are the key drivers to the success of chemical looping process development. In order to better understand and further scale up the chemical looping process, issues such as cost, time, measurement, safety, and other uncertainties need to be examined. To address these uncertainties, advanced reaction/reactor modeling and process simulation are highly desired and the modeling efforts can accelerate the chemical looping technology development, reduce the pilot-scale facility design time and operating campaigns, as well as reduce the cost and technical risks. The purpose of this work is thus to conduct multiscale modeling and simulations on the key aspects of chemical looping technology, including particle reaction kinetics, reactor design and operation, and process synthesis and optimization.

  20. Perception as a closed-loop convergence process.

    Science.gov (United States)

    Ahissar, Ehud; Assa, Eldad

    2016-05-09

    Perception of external objects involves sensory acquisition via the relevant sensory organs. A widely-accepted assumption is that the sensory organ is the first station in a serial chain of processing circuits leading to an internal circuit in which a percept emerges. This open-loop scheme, in which the interaction between the sensory organ and the environment is not affected by its concurrent downstream neuronal processing, is strongly challenged by behavioral and anatomical data. We present here a hypothesis in which the perception of external objects is a closed-loop dynamical process encompassing loops that integrate the organism and its environment and converging towards organism-environment steady-states. We discuss the consistency of closed-loop perception (CLP) with empirical data and show that it can be synthesized in a robotic setup. Testable predictions are proposed for empirical distinction between open and closed loop schemes of perception.

  1. Feedback Loop Gains and Feedback Behavior (1996)

    DEFF Research Database (Denmark)

    Kampmann, Christian Erik

    2012-01-01

    Linking feedback loops and system behavior is part of the foundation of system dynamics, yet the lack of formal tools has so far prevented a systematic application of the concept, except for very simple systems. Having such tools at their disposal would be a great help to analysts in understanding...... large, complicated simulation models. The paper applies tools from graph theory formally linking individual feedback loop strengths to the system eigenvalues. The significance of a link or a loop gain and an eigenvalue can be expressed in the eigenvalue elasticity, i.e., the relative change...... of an eigenvalue resulting from a relative change in the gain. The elasticities of individual links and loops may be found through simple matrix operations on the linearized system. Even though the number of feedback loops can grow rapidly with system size, reaching astronomical proportions even for modest systems...

  2. Two-Loop Splitting Amplitudes

    International Nuclear Information System (INIS)

    Bern, Z.

    2004-01-01

    Splitting amplitudes govern the behavior of scattering amplitudes at the momenta of external legs become collinear. In this talk we outline the calculation of two-loop splitting amplitudes via the unitarity sewing method. This method retains the simple factorization properties of light-cone gauge, but avoids the need for prescriptions such as the principal value or Mandelstam-Leibbrandt ones. The encountered loop momentum integrals are then evaluated using integration-by-parts and Lorentz invariance identities. We outline a variety of applications for these splitting amplitudes

  3. Two-loop splitting amplitudes

    International Nuclear Information System (INIS)

    Bern, Z.; Dixon, L.J.; Kosower, D.A.

    2004-01-01

    Splitting amplitudes govern the behavior of scattering amplitudes at the momenta of external legs become collinear. In this talk we outline the calculation of two-loop splitting amplitudes via the unitarity sewing method. This method retains the simple factorization properties of light-cone gauge, but avoids the need for prescriptions such as the principal value or Mandelstam-Leibbrandt ones. The encountered loop momentum integrals are then evaluated using integration-by-parts and Lorentz invariance identities. We outline a variety of applications for these splitting amplitudes

  4. Results from GRACE/SUSY at one-loop

    International Nuclear Information System (INIS)

    Fujimoto, J.; Ishikawa, T.; Kurihara, Y.; Jimbo, M.; Yasui, Y.; Kaneko, T.; Kon, T.; Kuroda, M.; Shimizu, Y.

    2007-01-01

    We report the recent development on the SUSY calculations with the help of GRACE system. GRACE/SUSY/1LOOP is the computer code which can generate Feynman diagrams in the MSSM automatically and compute one-loop amplitudes in the numerical way. We present new results of various two-body widths and chargino pair production at ILC (international linear collider) at one-loop level. (author)

  5. LMFBR with booster pump in pumping loop

    International Nuclear Information System (INIS)

    Rubinstein, H.J.

    1975-01-01

    A loop coolant circulation system is described for a liquid metal fast breeder reactor (LMFBR) utilizing a low head, high specific speed booster pump in the hot leg of the coolant loop with the main pump located in the cold leg of the loop, thereby providing the advantages of operating the main pump in the hot leg with the reliability of cold leg pump operation

  6. Computational advantages of reverberating loops for sensorimotor learning.

    Science.gov (United States)

    Fortney, Kristen; Tweed, Douglas B

    2012-03-01

    When we learn something new, our brain may store the information in synapses or in reverberating loops of electrical activity, but current theories of motor learning focus almost entirely on the synapses. Here we show that loops could also play a role and would bring advantages: loop-based algorithms can learn complex control tasks faster, with exponentially fewer neurons, and avoid the problem of weight transport. They do all this at a cost: in the presence of long feedback delays, loop algorithms cannot control very fast movements, but in this case, loop and synaptic mechanisms can complement each other-mixed systems quickly learn to make accurate but not very fast motions and then gradually speed up. Loop algorithms explain aspects of consolidation, the role of attention, and the relapses that are sometimes seen after a task has apparently been learned, and they make further predictions.

  7. Innovative hybrid pile oscillator technique in the Minerve reactor: open loop vs. closed loop

    Science.gov (United States)

    Geslot, Benoit; Gruel, Adrien; Bréaud, Stéphane; Leconte, Pierre; Blaise, Patrick

    2018-01-01

    Pile oscillator techniques are powerful methods to measure small reactivity worth of isotopes of interest for nuclear data improvement. This kind of experiments has long been implemented in the Mineve experimental reactor, operated by CEA Cadarache. A hybrid technique, mixing reactivity worth estimation and measurement of small changes around test samples is presented here. It was made possible after the development of high sensitivity miniature fission chambers introduced next to the irradiation channel. A test campaign, called MAESTRO-SL, took place in 2015. Its objective was to assess the feasibility of the hybrid method and investigate the possibility to separate mixed neutron effects, such as fission/capture or scattering/capture. Experimental results are presented and discussed in this paper, which focus on comparing two measurements setups, one using a power control system (closed loop) and another one where the power is free to drift (open loop). First, it is demonstrated that open loop is equivalent to closed loop. Uncertainty management and methods reproducibility are discussed. Second, results show that measuring the flux depression around oscillated samples provides valuable information regarding partial neutron cross sections. The technique is found to be very sensitive to the capture cross section at the expense of scattering, making it very useful to measure small capture effects of highly scattering samples.

  8. Thermal instabilities in magnetically confined plasmas: Solar coronal loops

    International Nuclear Information System (INIS)

    Habbal, S.R.; Rosner, R.

    1979-01-01

    The thermal stability of confined solar coronal structures (''loops'') is investigated, following both normal mode and a new, global instability analysis. We demonstrate that: (a) normal mode analysis shows modes with size scales comparable to that of loops to be unstable, but to be strongly affected by the loop boundary conditions; (b) a global analysis, based upon variation of the total loop energy losses and gains, yields loop stability conditions for global modes dependent upon the coronal loop heating process, with magnetically coupled heating processes giving marginal stability. The connection between the present analysis and the minimum flux corona of Hearn is also discussed

  9. Hypothyroidism: Can It Cause Peripheral Neuropathy?

    Science.gov (United States)

    Hypothyroidism: Can it cause peripheral neuropathy? Can hypothyroidism cause peripheral neuropathy and, if so, how is it treated? Answers from Todd B. Nippoldt, M.D. Hypothyroidism — a condition in which your ...

  10. Peripheral ameloblastic fibro-odontoma or peripheral developing complex odontoma: report of a case

    DEFF Research Database (Denmark)

    Reibel, Jesper; Grønbæk, Anni Birgitte; Poulsen, Sven

    2011-01-01

    BACKGROUND. Peripheral (extraosseous) odontogenic tumors are rare. CASE REPORT. This report describes a case which illustrates the clinical and histopathological features of a lesion in an 8-year-old, healthy Caucasian girl that on purely morphological grounds would seem to be an ameloblastic fibro-odontoma......, but may represent a case of a peripheral developing complex odontoma. CONCLUSION. Conservative surgical enucleation of the lesion was followed by unbcomplicated healing and no recurrence was seen....

  11. Feedback loop compensates for rectifier nonlinearity

    Science.gov (United States)

    1966-01-01

    Signal processing circuit with two negative feedback loops rectifies two sinusoidal signals which are 180 degrees out of phase and produces a single full-wave rectified output signal. Each feedback loop incorporates a feedback rectifier to compensate for the nonlinearity of the circuit.

  12. Observing string breaking with Wilson loops

    CERN Document Server

    Kratochvila, S; Kratochvila, Slavo; Forcrand, Philippe de

    2003-01-01

    An uncontroversial observation of adjoint string breaking is proposed, while measuring the static potential from Wilson loops only. The overlap of the Wilson loop with the broken-string state is small, but non-vanishing, so that the broken-string groundstate can be seen if the Wilson loop is long enough. We demonstrate this in the context of the (2+1)d SU(2) adjoint static potential, using an improved version of the Luscher-Weisz exponential variance reduction. To complete the picture we perform the more usual multichannel analysis with two basis states, the unbroken-string state and the broken-string state (two so-called gluelumps). As by-products, we obtain the temperature-dependent static potential measured from Polyakov loop correlations, and the fundamental SU(2) static potential with improved accuracy. Comparing the latter with the adjoint potential, we see clear deviations from Casimir scaling.

  13. Promoting peripheral myelin repair

    OpenAIRE

    Zhou, Ye; Notterpek, Lucia

    2016-01-01

    Compared to the central nervous system (CNS), peripheral nerves have a remarkable ability to regenerate and remyelinate. This regenerative capacity to a large extent is dependent on and supported by Schwann cells, the myelin-forming glial cells of the peripheral nervous system (PNS). In a variety of paradigms, Schwann cells are critical in the removal of the degenerated tissue, which is followed by remyelination of newly-regenerated axons. This unique plasticity of Schwann cells has been the ...

  14. Near BPS Wilson loop in β-deformed theories

    International Nuclear Information System (INIS)

    Chu, C-S; Giataganas, Dimitrios

    2007-01-01

    We propose a definition of the Wilson loop operator in the N = 1 β-deformed supersymmetric Yang-Mills theory. Although the operator is not BPS, it has a finite expectation value at least up to order (g 2 N) 2 . This does not happen generally for a generic non-BPS Wilson loop whose expectation value is UV divergent. For this reason we call this a near-BPS Wilson loop. We derive the general form of the boundary condition satisfied by the dual string worldsheet and find that it is deformed. Finiteness of the expectation value of the Wilson loop fixes the boundary condition to be one which is characterized by the vielbein of the deformed supergravity metric. The Wilson loop operators provide natural candidates as dual descriptions to some of the existing D-brane configurations in the Lunin-Maldacena background. We also construct the string dual configuration for a near-1/4 BPS circular Wilson loop operator. The string lies on a deformed three-sphere instead of a two-sphere as in the undeformed case. The expectation value of the Wilson loop operator is computed using the AdS/CFT correspondence and is found to be independent of the deformation. We conjecture that the exact expectation value of the Wilson loop is given by the same matrix model as in the undeformed case

  15. Digital subtraction angiography (DSA) of aortocoronary bypass grafts in the early postoperative phase with peripheral-venous contrast medium injection

    International Nuclear Information System (INIS)

    Tuengerthal, S.; Lang, J.; Donhoeffner, A.

    1985-01-01

    Using a fully digitalised subtraction unit, aortocoronary bypass grafts can be visualised in the early postoperative phase by means of peripheral venous contrast medium injection (57 out of a total of 60 cases). In more than one-half of the cases (31 out of a total of 60), it is possible to outline sharply the bypass grafts from the beginning to their entry into the bridged-over coronary artery, in such a manner that any loops, kinks, stenoses or reduced flow rates can be recognised. This examination is not considered to be an invasive one by the patient, and the cardiosurgeon can welcome it as a valuable additional means of controlling and assessing the results of surgery. (orig.) [de

  16. A virtual closed loop method for closed loop identification

    NARCIS (Netherlands)

    Agüero, J.C.; Goodwin, G.C.; Hof, Van den P.M.J.

    2011-01-01

    Indirect methods for the identification of linear plant models on the basis of closed loop data are based on the use of (reconstructed) input signals that are uncorrelated with the noise. This generally requires exact (linear) controller knowledge. On the other hand, direct identification requires

  17. Mass inflation in the loop black hole

    International Nuclear Information System (INIS)

    Brown, Eric G.; Mann, Robert; Modesto, Leonardo

    2011-01-01

    In classical general relativity the Cauchy horizon within a two-horizon black hole is unstable via a phenomenon known as mass inflation, in which the mass parameter (and the spacetime curvature) of the black hole diverges at the Cauchy horizon. Here we study this effect for loop black holes - quantum gravitationally corrected black holes from loop quantum gravity - whose construction alleviates the r=0 singularity present in their classical counterparts. We use a simplified model of mass inflation, which makes use of the generalized Dray-'t Hooft relation, to conclude that the Cauchy horizon of loop black holes indeed results in a curvature singularity similar to that found in classical black holes. The Dray-'t Hooft relation is of particular utility in the loop black hole because it does not directly rely upon Einstein's field equations. We elucidate some of the interesting and counterintuitive properties of the loop black hole, and corroborate our results using an alternate model of mass inflation due to Ori.

  18. A comparative approach to closed-loop computation.

    Science.gov (United States)

    Roth, E; Sponberg, S; Cowan, N J

    2014-04-01

    Neural computation is inescapably closed-loop: the nervous system processes sensory signals to shape motor output, and motor output consequently shapes sensory input. Technological advances have enabled neuroscientists to close, open, and alter feedback loops in a wide range of experimental preparations. The experimental capability of manipulating the topology-that is, how information can flow between subsystems-provides new opportunities to understand the mechanisms and computations underlying behavior. These experiments encompass a spectrum of approaches from fully open-loop, restrained preparations to the fully closed-loop character of free behavior. Control theory and system identification provide a clear computational framework for relating these experimental approaches. We describe recent progress and new directions for translating experiments at one level in this spectrum to predictions at another level. Operating across this spectrum can reveal new understanding of how low-level neural mechanisms relate to high-level function during closed-loop behavior. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Decoding the Mobility and Time Scales of Protein Loops.

    Science.gov (United States)

    Gu, Yina; Li, Da-Wei; Brüschweiler, Rafael

    2015-03-10

    The flexible nature of protein loops and the time scales of their dynamics are critical for many biologically important events at the molecular level, such as protein interaction and recognition processes. In order to obtain a predictive understanding of the dynamic properties of loops, 500 ns molecular dynamics (MD) computer simulations of 38 different proteins were performed and validated using NMR chemical shifts. A total of 169 loops were analyzed and classified into three types, namely fast loops with correlation times Web server (http://spin.ccic.ohio-state.edu/index.php/loop). The results demonstrate that loop dynamics with their time scales can be predicted rapidly with reasonable accuracy, which will allow the screening of average protein structures to help better understand the various roles loops can play in the context of protein-protein interactions and binding.

  20. Peripheral cemento-ossifying fibroma of maxilla.

    Science.gov (United States)

    Chatterjee, Anirban; Ajmera, Neha; Singh, Amit

    2010-07-01

    Peripheral cemento-ossifying fibroma is a reactive gingival overgrowth occurring frequently in anterior maxilla. It is a slow-growing benign tumor which may lead to pathologic migration and other periodontal problems, so it should be excised as soon as possible. The recurrence rate of peripheral cemento-ossifying fibroma is reported to be 8% to 20%, so a close postoperative follow-up is required. Herein, we are reporting a similar case of peripheral cemento-ossifying fibroma in the maxillary anterior region.

  1. Shortening a loop can increase protein native state entropy.

    Science.gov (United States)

    Gavrilov, Yulian; Dagan, Shlomi; Levy, Yaakov

    2015-12-01

    Protein loops are essential structural elements that influence not only function but also protein stability and folding rates. It was recently reported that shortening a loop in the AcP protein may increase its native state conformational entropy. This effect on the entropy of the folded state can be much larger than the lower entropic penalty of ordering a shorter loop upon folding, and can therefore result in a more pronounced stabilization than predicted by polymer model for loop closure entropy. In this study, which aims at generalizing the effect of loop length shortening on native state dynamics, we use all-atom molecular dynamics simulations to study how gradual shortening a very long or solvent-exposed loop region in four different proteins can affect their stability. For two proteins, AcP and Ubc7, we show an increase in native state entropy in addition to the known effect of the loop length on the unfolded state entropy. However, for two permutants of SH3 domain, shortening a loop results only with the expected change in the entropy of the unfolded state, which nicely reproduces the observed experimental stabilization. Here, we show that an increase in the native state entropy following loop shortening is not unique to the AcP protein, yet nor is it a general rule that applies to all proteins following the truncation of any loop. This modification of the loop length on the folded state and on the unfolded state may result with a greater effect on protein stability. © 2015 Wiley Periodicals, Inc.

  2. Coaching Peripheral Vision Training for Soccer Athletes

    Science.gov (United States)

    Marques, Nelson Kautzner, Jr.

    2010-01-01

    Brazilian Soccer began developing its current emphasis on peripheral vision in the late 1950s, by initiative of coach of the Canto do Rio Football Club, in Niteroi, Rio de Janeiro, a pioneer in the development of peripheral vision training in soccer players. Peripheral vision training gained world relevance when a young talent from Canto do Rio,…

  3. Numerical approach to one-loop integrals

    International Nuclear Information System (INIS)

    Fujimoto, Junpei; Shimizu, Yoshimitsu; Kato, Kiyoshi; Oyanagi, Yoshio.

    1992-01-01

    Two numerical methods are proposed for the calculation of one-loop scalar integrals. In the first method, the singularity is cancelled by the symmetrization of the integrand and the integration is done by a Monte-Carlo method. In the second one, after the transform of the integrand into a standard form, the integral is reduced into a regular numerical integral. These methods provide us practical tools to evaluate one-loop Feynman diagrams with desired numerical accuracy. They are extended to the integral with numerator and the treatment of the one-loop virtual correction to the cross section is also presented. (author)

  4. Loop corrections to primordial non-Gaussianity

    Science.gov (United States)

    Boran, Sibel; Kahya, E. O.

    2018-02-01

    We discuss quantum gravitational loop effects to observable quantities such as curvature power spectrum and primordial non-Gaussianity of cosmic microwave background (CMB) radiation. We first review the previously shown case where one gets a time dependence for zeta-zeta correlator due to loop corrections. Then we investigate the effect of loop corrections to primordial non-Gaussianity of CMB. We conclude that, even with a single scalar inflaton, one might get a huge value for non-Gaussianity which would exceed the observed value by at least 30 orders of magnitude. Finally we discuss the consequences of this result for scalar driven inflationary models.

  5. [Ultrasound-guided peripheral catheterization].

    Science.gov (United States)

    Salleras-Duran, Laia; Fuentes-Pumarola, Concepció

    2016-01-01

    Peripheral catheterization is a technique that can be difficult in some patients. Some studies have recently described the use of ultrasound to guide the venous catheterization. To describe the success rate, time required, complications of ultrasound-guided peripheral venous catheterization. and patients and professionals satisfaction The search was performed in databases (Medline-PubMed, Cochrane Library, CINAHL and Cuiden Plus) for studies published about ultrasound-guided peripheral venous catheterization performed on patients that provided results on the success of the technique, complications, time used, patient satisfaction and the type of professional who performed the technique. A total of 21 studies were included. Most of them get a higher success rate 80% in the catheterization ecoguide and time it is not higher than the traditional technique. The Technical complications analyzed were arterial puncture rates and lower nerve 10%. In all studies measuring and comparing patient satisfaction in the art ecoguide is greater. Various professional groups perform the technique. The use of ultrasound for peripheral pipes has a high success rate, complications are rare and the time used is similar to that of the traditional technique. The technique of inserting catheters through ultrasound may be learned by any professional group performing venipuncture. Finally, it gets underscores the high patient satisfaction with the use of this technique. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  6. Thermodynamics in Loop Quantum Cosmology

    International Nuclear Information System (INIS)

    Li, L.F.; Zhu, J.Y.

    2009-01-01

    Loop quantum cosmology (LQC) is very powerful to deal with the behavior of early universe. Moreover, the effective loop quantum cosmology gives a successful description of the universe in the semiclassical region. We consider the apparent horizon of the Friedmann-Robertson-Walker universe as a thermodynamical system and investigate the thermodynamics of LQC in the semiclassical region. The effective density and effective pressure in the modified Friedmann equation from LQC not only determine the evolution of the universe in LQC scenario but also are actually found to be the thermodynamic quantities. This result comes from the energy definition in cosmology (the Misner-Sharp gravitational energy) and is consistent with thermodynamic laws. We prove that within the framework of loop quantum cosmology, the elementary equation of equilibrium thermodynamics is still valid.

  7. Five-loop Konishi in N=4 SYM

    International Nuclear Information System (INIS)

    Eden, Burkhard; Heslop, Paul; Korchemsky, Gregory P.; Smirnov, Vladimir A.; Sokatchev, Emery

    2012-01-01

    We present a new method for computing the Konishi anomalous dimension in N=4 SYM at weak coupling. It does not rely on the conventional Feynman diagram technique and is not restricted to the planar limit. It is based on the OPE analysis of the four-point correlation function of stress-tensor multiplets, which has been recently constructed up to six loops. The Konishi operator gives the leading contribution to the singlet SU(4) channel of this OPE. Its anomalous dimension is the coefficient of the leading single logarithmic singularity of the logarithm of the correlation function in the double short-distance limit, in which the operator positions coincide pairwise. We regularize the logarithm of the correlation function in this singular limit by a version of dimensional regularization. At any loop level, the resulting singularity is a simple pole whose residue is determined by a finite two-point integral with one loop less. This drastically simplifies the five-loop calculation of the Konishi anomalous dimension by reducing it to a set of known four-loop two-point integrals and two unknown integrals which we evaluate analytically. We obtain an analytic result at five loops in the planar limit and observe perfect agreement with the prediction based on integrability in AdS/CFT.

  8. Normal and sonographic anatomy of selected peripheral nerves. Part III: Peripheral nerves of the lower limb

    Directory of Open Access Journals (Sweden)

    Berta Kowalska

    2012-06-01

    Full Text Available The ultrasonographic examination is currently increasingly used in imaging peripheral nerves, serving to supplement the physical examination, electromyography and magnetic resonance imaging. As in the case of other USG imaging studies, the examination of peripheral nerves is non-invasive and well-tolerated by patients. The typical ultrasonographic picture of peripheral nerves as well as the examination technique have been discussed in part I of this article series, following the example of the median nerve. Part II of the series presented the normal anatomy and the technique for examining the peripheral nerves of the upper limb. This part of the article series focuses on the anatomy and technique for examining twelve normal peripheral nerves of the lower extremity: the iliohypogastric and ilioinguinal nerves, the lateral cutaneous nerve of the thigh, the pudendal, sciatic, tibial, sural, medial plantar, lateral plantar, common peroneal, deep peroneal and superficial peroneal nerves. It includes diagrams showing the proper positioning of the sonographic probe, plus USG images of the successively discussed nerves and their surrounding structures. The ultrasonographic appearance of the peripheral nerves in the lower limb is identical to the nerves in the upper limb. However, when imaging the lower extremity, convex probes are more often utilized, to capture deeply-seated nerves. The examination technique, similarly to that used in visualizing the nerves of upper extremity, consists of locating the nerve at a characteristic anatomic reference point and tracking it using the “elevator technique”. All 3 parts of the article series should serve as an introduction to a discussion of peripheral nerve pathologies, which will be presented in subsequent issues of the “Journal of Ultrasonography”.

  9. Closed Loop Supply Chains for Sustainable Mass Customization

    DEFF Research Database (Denmark)

    Nielsen, Kjeld; Brunø, Thomas Ditlev

    2013-01-01

    Closed loop supply chains reducing waste, energy consumption and natural resource depletion which all contribute to more sustainable production and products. For mass customization however, the challenges of closed loop supply chains are emphasized by the large variety of inbound end-of-life prod......Closed loop supply chains reducing waste, energy consumption and natural resource depletion which all contribute to more sustainable production and products. For mass customization however, the challenges of closed loop supply chains are emphasized by the large variety of inbound end...

  10. Design of diamagnetic loop on EAST superconducting tokamak

    International Nuclear Information System (INIS)

    Xi Weibin; Shen Biao; Qian Jinping; Wu Songtao; Wan Baonan

    2007-01-01

    The design of EAST diamagnetic measurement system including diamagnetic loop and compensation loop has been given. The advantage of this method is that, the compensation loop is applied for eliminating the change of toroidal flux produced by the toroidal coils and the adjustable structure can be used to decrease the error signals come from the poloidal field. On the other hand, the effect of the material and structure on the diamagnetic loop is detailedly checked during engineering design. Error analysis of the measurement system is given. (authors)

  11. Stepping out of homogeneity in loop quantum cosmology

    International Nuclear Information System (INIS)

    Rovelli, Carlo; Vidotto, Francesca

    2008-01-01

    We explore the extension of quantum cosmology outside the homogeneous approximation using the formalism of loop quantum gravity. We introduce a model where some of the inhomogeneous degrees of freedom are present, providing a tool for describing general fluctuations of quantum geometry near the initial singularity. We show that the dynamical structure of the model reduces to that of loop quantum cosmology in the Born-Oppenheimer approximation. This result corroborates the assumptions that ground loop cosmology sheds some light on the physical and mathematical relation between loop cosmology and full loop quantum gravity, and on the nature of the cosmological approximation. Finally, we show that the non-graph-changing Hamiltonian constraint considered in the context of algebraic quantum gravity provides a viable effective dynamics within this approximation

  12. Tree-loop duality relation beyond single poles

    Energy Technology Data Exchange (ETDEWEB)

    Bierenbaum, Isabella [Hamburg Univ. (Germany). 2. Inst. fuer Theoretische Physik; Buchta, Sebastian; Draggiotis, Petros; Malamos, Ioannis; Rodrigo, German [Valencia Univ. Paterna (Spain). Inst. de Fisica Corpuscular

    2012-11-15

    We develop the Tree-Loop Duality Relation for two- and three-loop integrals with multiple identical propagators (multiple poles). This is the extension of the Duality Relation for single poles and multi-loop integrals derived in previous publications. We prove a generalization of the formula for single poles to multiple poles and we develop a strategy for dealing with higher-order pole integrals by reducing them to single pole integrals using Integration By Parts.

  13. Peripheral Neuropathy – Clinical and Electrophysiological Considerations

    Science.gov (United States)

    Chung, Tae; Prasad, Kalpana; Lloyd, Thomas E.

    2013-01-01

    This article is a primer on the pathophysiology and clinical evaluation of peripheral neuropathy for the radiologist. Magnetic resonance neurography (MRN) has utility in the diagnosis of many focal peripheral nerve lesions. When combined with history, examination, electrophysiology, and laboratory data, future advancements in high-field MRN may play an increasingly important role in the evaluation of patients with peripheral neuropathy. PMID:24210312

  14. On the Loop Current Penetration into the Gulf of Mexico

    Science.gov (United States)

    Weisberg, Robert H.; Liu, Yonggang

    2017-12-01

    The Gulf of Mexico Loop Current generally intrudes some distance into the Gulf of Mexico before shedding an anticyclonic eddy and retreating back to its more direct entry to exit pathway. The control of this aperiodic process remains only partially known. Here we describe the evolution of the Loop Current throughout the era of satellite altimetry, and offer a mechanistic hypothesis on Loop Current intrusion. As a complement to the known effects of Loop Current forcing on the west Florida shelf circulation, we argue that the west Florida shelf, in turn, impacts the Loop Current evolution. A Self-Organizing Map analysis shows that anomalous northward penetrations of the Loop Current into the Gulf of Mexico occur when the eastern side of Loop Current is positioned west from the southwest corner of the west Florida shelf, whereas the more direct inflow to outflow route occurs when the eastern side of the Loop Current comes in contact with the southwest corner of the west Florida shelf. In essence, we argue that the west Florida shelf anchors the Loop Current in its direct path configuration and that farther northward penetration into the Gulf of Mexico occurs when such anchoring is released. To test of this hypothesis heuristically, we estimate that the dissipation and buoyancy work due to known Loop Current forcing of the west Florida shelf circulation (when in contact with the southwest corner) may exceed the pressure work required for the Loop Current to advance against the ambient Gulf of Mexico fluid.Plain Language SummaryThe Gulf of Mexico Loop Current may intrude far into the Gulf of Mexico or take a more direct entry to exit pathway. Such Loop Current behaviors are described using remote observations by satellites, and a heuristic hypothesis on the control of Loop Current intrusion is presented. We argue that energy dissipation and buoyancy work by the west Florida shelf circulation, when the Loop Current contacts the southwest corner of the west Florida shelf

  15. Newtonian gravity in loop quantum gravity

    OpenAIRE

    Smolin, Lee

    2010-01-01

    We apply a recent argument of Verlinde to loop quantum gravity, to conclude that Newton's law of gravity emerges in an appropriate limit and setting. This is possible because the relationship between area and entropy is realized in loop quantum gravity when boundaries are imposed on a quantum spacetime.

  16. Two-loop off-shell QCD amplitudes in FDR

    CERN Document Server

    Page, Ben

    2015-01-01

    We link the FDR treatment of ultraviolet (UV) divergences to dimensional regularization up to two loops in QCD. This allows us to derive the one-loop and two-loop coupling constant and quark mass shifts necessary to translate infrared finite quantities computed in FDR to the MSbar renormalization scheme. As a by-product of our analysis, we solve a problem analogous to the breakdown of unitarity in the Four Dimensional Helicity (FDH) method beyond one loop. A fix to FDH is then presented that preserves the renormalizability properties of QCD without introducing evanescent quantities.

  17. The challenges and beauty of peripheral nerve regrowth.

    Science.gov (United States)

    Zochodne, Douglas W

    2012-03-01

    This review provides an overview of selected aspects of peripheral nerve regeneration and potential avenues to explore therapeutically. The overall coordinated and orchestrated pattern of recovery from peripheral nerve injury has a beauty of execution and progress that rivals all other forms of neurobiology. It involves changes at the level of the perikaryon, coordination with important peripheral glial partners, the Schwann cells, a controlled inflammatory response, and growth that overcomes surprising intrinsic roadblocks. Both regenerative axon growth and collateral sprouting encompass fascinating aspects of this story. Better understanding of peripheral nerve regeneration may also lead to enhanced central nervous system recovery. © 2012 Peripheral Nerve Society.

  18. Universality hypothesis breakdown at one-loop order

    Science.gov (United States)

    Carvalho, P. R. S.

    2018-05-01

    We probe the universality hypothesis by analytically computing the at least two-loop corrections to the critical exponents for q -deformed O (N ) self-interacting λ ϕ4 scalar field theories through six distinct and independent field-theoretic renormalization group methods and ɛ -expansion techniques. We show that the effect of q deformation on the one-loop corrections to the q -deformed critical exponents is null, so the universality hypothesis is broken down at this loop order. Such an effect emerges only at the two-loop and higher levels, and the validity of the universality hypothesis is restored. The q -deformed critical exponents obtained through the six methods are the same and, furthermore, reduce to their nondeformed values in the appropriated limit.

  19. Innovative hybrid pile oscillator technique in the Minerve reactor: open loop vs. closed loop

    Directory of Open Access Journals (Sweden)

    Geslot Benoit

    2018-01-01

    Full Text Available Pile oscillator techniques are powerful methods to measure small reactivity worth of isotopes of interest for nuclear data improvement. This kind of experiments has long been implemented in the Mineve experimental reactor, operated by CEA Cadarache. A hybrid technique, mixing reactivity worth estimation and measurement of small changes around test samples is presented here. It was made possible after the development of high sensitivity miniature fission chambers introduced next to the irradiation channel. A test campaign, called MAESTRO-SL, took place in 2015. Its objective was to assess the feasibility of the hybrid method and investigate the possibility to separate mixed neutron effects, such as fission/capture or scattering/capture. Experimental results are presented and discussed in this paper, which focus on comparing two measurements setups, one using a power control system (closed loop and another one where the power is free to drift (open loop. First, it is demonstrated that open loop is equivalent to closed loop. Uncertainty management and methods reproducibility are discussed. Second, results show that measuring the flux depression around oscillated samples provides valuable information regarding partial neutron cross sections. The technique is found to be very sensitive to the capture cross section at the expense of scattering, making it very useful to measure small capture effects of highly scattering samples.

  20. Electron acceleration and radiation signatures in loop coronal transients

    International Nuclear Information System (INIS)

    Vlahos, L.; Gergely, T.E.; Papadopoulos, K.

    1982-01-01

    A model for electron aceleration in loop coronal transients is suggested. We propose that in these transients an erupting loop moves away from the solar surface, with a velocity greater than the local Alfven speed, pushing against the overlying magnetic fields and driving a shock in the front of the moving part of the loop. We suggest that lower hybrid waves are excited at the shock front and propagate radially toward the center of the loop with phase velocity along the magnetic field which exceeds the thermal velocity. The lower hybrid waves stochastically accelerate the tail of the electron distribution inside the loop. We discuss how the accelerated electrons are trapped in the moving loop and give a rough estimate of their radiation signature. We find that plasma radiation can explain the power observed in stationary and moving type IV bursts. We discuss some of the conditions under which moving or stationary type IV bursts are expected to be associated with loop coronal transients

  1. Mass transfer of steels for FBR in sodium loop

    International Nuclear Information System (INIS)

    Susukida, Hiroshi; Yonezawa, Toshio; Ueda, Mitsuo; Imazu, Takayuki; Kiyokawa, Teruyuki.

    1976-06-01

    In order to grasp quantitatively the corrosion and mass transfer of steels for FBR in sodium loop and to establish their allowable stress value and corrosion rate, a special sodium loop for material testing was designed and fabricated and the steels were given 3010 hours exposing test in the sodium loop. This paper gives the outline of the sodium loop and the results of the test. (1) Carburization and a slight increase in weight were observed in the specimens of type 304 stainless steel exposed in the sodium loop for 3010 hours, while decarburization was observed in the specimens of 2 1/4 Cr-1 Mo steel. It is considered that these phenomena were caused by the downstream factor of the sodium loop. (2) A remarkable decrease of Charpy absorbed energy was observed in the specimens of type 304 stainless steel exposed in the sodium loop. It is considered that this resulted from the weakening of the grain boundary due to heat history and mass transfer. (3) The specimens exposed in the sodium loop must be washed by ultrasonic waves in a water bath after washing in alcohol. (auth.)

  2. Odontogenic keratocyst: a peripheral variant.

    Science.gov (United States)

    Vij, H; Vij, R; Gupta, V; Sengupta, S

    2011-01-01

    Odontogenic keratocyst, which is developmental in nature, is an intraosseous lesion though on rare occasions it may occur in an extraosseous location. The extraosseous variant is referred to as peripheral odontogenic keratocyst. Though, clinically, peripheral odontogenic keratocyst resembles the gingival cyst of adults, it has histologic features that are pathognomonic of odontogenic keratocyst. This article presents a case of this uncommon entity.

  3. R-loops: targets for nuclease cleavage and repeat instability.

    Science.gov (United States)

    Freudenreich, Catherine H

    2018-01-11

    R-loops form when transcribed RNA remains bound to its DNA template to form a stable RNA:DNA hybrid. Stable R-loops form when the RNA is purine-rich, and are further stabilized by DNA secondary structures on the non-template strand. Interestingly, many expandable and disease-causing repeat sequences form stable R-loops, and R-loops can contribute to repeat instability. Repeat expansions are responsible for multiple neurodegenerative diseases, including Huntington's disease, myotonic dystrophy, and several types of ataxias. Recently, it was found that R-loops at an expanded CAG/CTG repeat tract cause DNA breaks as well as repeat instability (Su and Freudenreich, Proc Natl Acad Sci USA 114, E8392-E8401, 2017). Two factors were identified as causing R-loop-dependent breaks at CAG/CTG tracts: deamination of cytosines and the MutLγ (Mlh1-Mlh3) endonuclease, defining two new mechanisms for how R-loops can generate DNA breaks (Su and Freudenreich, Proc Natl Acad Sci USA 114, E8392-E8401, 2017). Following R-loop-dependent nicking, base excision repair resulted in repeat instability. These results have implications for human repeat expansion diseases and provide a paradigm for how RNA:DNA hybrids can cause genome instability at structure-forming DNA sequences. This perspective summarizes mechanisms of R-loop-induced fragility at G-rich repeats and new links between DNA breaks and repeat instability.

  4. Operation of the hot test loop facilities

    International Nuclear Information System (INIS)

    Cheong, Moon Ki; Park, Choon Kyeong; Won, Soon Yeon; Yang, Sun Kyu; Cheong, Jang Whan; Cheon, Se Young; Song, Chul Hwa; Jeon, Hyeong Kil; Chang, Suk Kyu; Jeong, Heung Jun; Cho, Young Ro; Kim, Bok Duk; Min, Kyeong Ho

    1994-12-01

    The objective of this project is to obtain the available experimental data and to develop the measuring techniques through taking full advantage of the facilities. The facilities operated by the thermal hydraulics department have been maintained and repaired in order to carry out the thermal hydraulics tests necessary for providing the available data. The performance tests for double grid type bottom end piece which was improved on the debris filtering effectivity were performed using the PWR-Hot Test Loop. The CANDU-Hot Test Loop was operated to carry out the pressure drop tests and strength tests of fuel. The Cold Test Loop was used to obtain the local velocity data in subchannel within fuel bundle and to understand the characteristic of pressure drop required for improving the nuclear fuel and to develop the advanced measuring techniques. RCS Loop, which is used to measure the CHF, is presently under design and construction. B and C Loop is designed and constructed to assess the automatic depressurization safety system behavior. 4 tabs., 79 figs., 7 refs. (Author) .new

  5. Design factors analyses of second-loop PRHRS

    Directory of Open Access Journals (Sweden)

    ZHANG Hongyan

    2017-05-01

    Full Text Available In order to study the operating characteristics of a second-loop Passive Residual Heat Removal System (PRHRS, the transient thermal analysis code RELAP5 is used to build simulation models of the main coolant system and second-loop PRHRS. Transient calculations and comparative analyses under station blackout accident and one-side feed water line break accident conditions are conducted for three critical design factors of the second-loop PRHRS:design capacity, emergency makeup tank and isolation valve opening speed. The impacts of the discussed design factors on the operating characteristics of the second-loop PRHRS are summarized based on calculations and analyses. The analysis results indicate that the system safety and cooling rate should be taken into consideration in designing PRHRS's capacity,and water injection from emergency makeup tank to steam generator can provide advantage to system cooling in the event of accident,and system startup performance can be improved by reducing the opening speed of isolation valve. The results can provide references for the design of the second-loop PRHRS in nuclear power plants.

  6. Stability analysis for single-phase liquid metal rectangular natural circulation loops

    International Nuclear Information System (INIS)

    Lu, Daogang; Zhang, Xun; Guo, Chao

    2014-01-01

    Highlights: • The stability for asymmetric liquid metal natural circulation loops is analyzed. • The Na and NaK loops have higher critical Reynolds number than Pb and LBE loops. • Decreasing the ratio of height to width of loop can increase loop stability. • The length of heater would not affect the loop stability obviously. • Adding the length or heat transfer coefficient of cooler can increase loop stability. - Abstract: Natural circulation systems are preferred in some advanced nuclear power plants as they can simplify the designs and improve the inherent safety. The stability and steady-state characteristics of natural circulation are important for the applications of natural circulation loops (NCLs). A linear stability analysis method was used to study the stability behavior of liquid metal NCLs. The influences of the types of working fluids and loop geometry parameters on the stability of NCLs were evaluated. The liquid sodium (Na) loop and sodium–potassium alloy (NaK) loop would be more stable than lead bismuth eutectics (LBE) loop. The pressure drop could stabilize the loop behavior and also lead an increase of operating temperature for the loop. The NCL with a lower aspect ratio (ratio of vertical center distance between the heating and cooling section to the horizontal length of loop) is supposed to be more stable. It was found that the length of heating section would not have an obvious effect on the stability of NCL. However, the loop behavior could be stabilized by adding the length or heat transfer coefficient of the cooling section

  7. Closing the loop.

    Science.gov (United States)

    Dassau, E; Atlas, E; Phillip, M

    2010-02-01

    The dream of closing the loop is actually the dream of creating an artificial pancreas and freeing the patients from being involved with the care of their own diabetes. Insulin-dependent diabetes (type 1) is a chronic incurable disease which requires constant therapy without the possibility of any 'holidays' or insulin-free days. It means that patients have to inject insulin every day of their life, several times per day, and in order to do it safely they also have to measure their blood glucose levels several times per day. Patients need to plan their meals, their physical activities and their insulin regime - there is only very small room for spontaneous activities. This is why the desire for an artificial pancreas is so strong despite the fact that it will not cure the diabetic patients. Attempts to develop a closed-loop system started in the 1960s but never got to a clinical practical stage of development. In recent years the availability of continuous glucose sensors revived those efforts and stimulated the clinician and researchers to believe that closing the loop might be possible nowadays. Many papers have been published over the years describing several different ideas on how to close the loop. Most of the suggested systems have a sensing arm that measures the blood glucose repeatedly or continuously, an insulin delivery arm that injects insulin upon command and a computer that makes the decisions of when and how much insulin to deliver. The differences between the various published systems in the literature are mainly in their control algorithms. However, there are also differences related to the method and site of glucose measurement and insulin delivery. SC glucose measurements and insulin delivery are the most studied option but other combinations of insulin measurements and glucose delivery including intravascular and intraperitoneal (IP) are explored. We tried to select recent publications that we believe had influenced and inspired people interested

  8. XLOOPS - a package calculating one- and two-loop diagrams

    International Nuclear Information System (INIS)

    Bruecher, L.

    1997-01-01

    A program package for calculating massive one- and two-loop diagrams is introduced. It consists of five parts: - a graphical user interface, - routines for generating diagrams from particle input, - procedures for calculating one-loop integrals both analytically and numerically, - routines for massive two-loop integrals, - programs for numerical integration of two-loop diagrams. Here the graphical user interface and the text interface to Maple are presented. (orig.)

  9. Analysis of severe accidents on fast reactor test loop

    International Nuclear Information System (INIS)

    Cenerini, R.; Verzelletti, G.; Curioni, S.

    1975-01-01

    The Pec reactor is a sodium cooled fast reactor which is being designed for the primary purpose of accomodating closed sodium cooled test loops for the developmental and proof testing of fast reactor fuel assemblies. The test loops are located in the central test region of reactor. The basic function for which the loop is designed is burn-up to failure testing of fuel under advanced performance conditions. It is therefore necessary to design the loop for failure conditions. Basically two types of accidents can occur within the loops: rupture of gas plenum in the fuel pins and coolant starvation. Explosive tests on Pec loop, whose first set is described in this report, are devoted to investigate the effects of an accidental energy release on loop containment. The loop model reproduces in the test section the prototype dimensions in radial scale 1:1. Using a wire explosive charge of 300mm, the height of test section is sufficient for determining the containment capability of the loop that has a nearly constant deformation in a length of. 3-4 time the diameter. The inertial effects of the coolant column are reproduced by two tubes at the extremities of test section, closed with top plugs. Some tests has been performed by wrapping around the test section four layers of steel wire in order to evaluate the influence on the containment of tungsten wire that is foreseen in prototype loop. The influence of the coolant around the loop was evaluated by inserting the model in water. Dummy sub-assemblies was used and explosive substitutes the central rods. Piezoelectric pressure transducers were mounted on the three plugs and radial deformation was measured directly at different height. From experiments performed it resulted the importance of harmonic wires and inertial reaction of external water on loop containment; maximum containable energy is about 50 Cal with E.1 explosive

  10. Blind loop syndrome

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/001146.htm Blind loop syndrome To use the sharing features on ... Clinical Professor of Medicine, The George Washington University School of Medicine, Washington, DC. Also reviewed by David ...

  11. On vanishing two loop cosmological constants in nonsupersymmetric strings

    International Nuclear Information System (INIS)

    Kachru, Shamit; Silverstein, Eva

    1998-01-01

    It has recently been suggested that in certain special nonsupersymmetric type II string compactifications, at least the first two perturbative contributions to the cosmological constant Λ vanish. Support for perturbative vanishing beyond 1-loop (as well as evidence for the absence of some nonperturbative contributions) has come from duality arguments. There was also a direct 2-loop computation which was incomplete; in this note we explain the deficiency of the previous 2-loop calculation and discuss the complete 2-loop computation in two different models. The corrected analysis yields a vanishing 2-loop contribution to Λ in these models

  12. On Vanishing Two Loop Cosmological Constants in Nonsupersymmetric Strings

    Energy Technology Data Exchange (ETDEWEB)

    Kachru, S

    1998-10-22

    It has recently been suggested that in certain special nonsupersymmetric type II string compactifications, at least the first two perturbative contributions to the cosmological constant Lambda vanish. Support for perturbative vanishing beyond 1-loop (as well as evidence for the absence of some nonperturbative contributions) has come from duality arguments. There was also a direct 2-loop computation which was incomplete; in this note we explain the deficiency of the previous 2-loop calculation and discuss the complete 2-loop computation in two different models. The corrected analysis yields a vanishing 2-loop contribution to Lambda in these models.

  13. One-loop calculations with massive particles

    International Nuclear Information System (INIS)

    Oldenborgh, G.J. van.

    1990-01-01

    In this thesis some techniques for performing one-loop calculations with massive particles are presented. Numerical techniques are presented necessary for evaluating one-loop integrals which occur in one-loop calculations of photon-photon scattering. The algorithms have been coded in FORTRAN (to evaluate the scalar integrals) and the algebraic language FORM (to reduce the tensor integrals to scalar integrals). Applications are made in the theory of the strong interaction, QCD, i.e. in handling one-loop integrals with massive particles, in order to regulate the infinities by mass parameters encountered in this theory. However this simplifies the computation considerably, the description of the proton structure functions have to be renormalized in order to obtain physical results. This renormalization is different from the published results for the gluon and thus has to be redone. The first physics results that have been obtained with these new methods are presented. These concern heavy quark production in semi-leptonic interactions, for instance neutrino charm production and top production at the electron-proton (ep) collider HERA and the proposed LEP/LHC combination. Total and differential cross-sections for one-loop corrections to top production at the HERA and proposed LEP/HLC ep colliders are given and structure functions for charmed quark production are compared with previously published results. (author). 58 refs.; 18 figs.; 5 tabs

  14. Logical inference techniques for loop parallelization

    KAUST Repository

    Oancea, Cosmin E.

    2012-01-01

    This paper presents a fully automatic approach to loop parallelization that integrates the use of static and run-time analysis and thus overcomes many known difficulties such as nonlinear and indirect array indexing and complex control flow. Our hybrid analysis framework validates the parallelization transformation by verifying the independence of the loop\\'s memory references. To this end it represents array references using the USR (uniform set representation) language and expresses the independence condition as an equation, S = Ø, where S is a set expression representing array indexes. Using a language instead of an array-abstraction representation for S results in a smaller number of conservative approximations but exhibits a potentially-high runtime cost. To alleviate this cost we introduce a language translation F from the USR set-expression language to an equally rich language of predicates (F(S) ⇒ S = Ø). Loop parallelization is then validated using a novel logic inference algorithm that factorizes the obtained complex predicates (F(S)) into a sequence of sufficient-independence conditions that are evaluated first statically and, when needed, dynamically, in increasing order of their estimated complexities. We evaluate our automated solution on 26 benchmarks from PERFECTCLUB and SPEC suites and show that our approach is effective in parallelizing large, complex loops and obtains much better full program speedups than the Intel and IBM Fortran compilers. Copyright © 2012 ACM.

  15. Coronal Loop Evolution Observed with AIA and Hi-C

    Science.gov (United States)

    Mulu-Moore, Fana; Winebarger, A.; Cirtain, J.; Kobayashi, K.; Korreck, K.; Golub, L.; Kuzin. S.; Walsh, R.; DeForest, C.; DePontieu, B.; hide

    2012-01-01

    Despite much progress toward understanding the dynamics of the solar corona, the physical properties of coronal loops are not yet fully understood. Recent investigations and observations from different instruments have yielded contradictory results about the true physical properties of coronal loops. In the past, the evolution of loops has been used to infer the loop substructure. With the recent launch of High Resolution Coronal Imager (Hi-C), this inference can be validated. In this poster we discuss the first results of loop analysis comparing AIA and Hi-C data. We find signatures of cooling in a pixel selected along a loop structure in the AIA multi-filter observations. However, unlike previous studies, we find that the cooling time is much longer than the draining time. This is inconsistent with previous cooling models.

  16. Electron acceleration and radiation signatures in loop coronal transients

    Science.gov (United States)

    Vlahos, L.; Gergely, T. E.; Papadopoulos, K.

    1982-01-01

    It is proposed that in loop coronal transients an erupting loop moves away from the solar surface, with a velocity exceeding the local Alfven speed, pushing against the overlying magnetic fields and driving a shock in the front of the moving part of the loop. Lower hybrid waves are excited at the shock front and propagate radially toward the center of the loop with phase velocity along the magnetic field that exceeds the thermal velocity. The lower hybrid waves stochastically accelerate the tail of the electron distribution inside the loop. The manner in which the accelerated electrons are trapped in the moving loop are discussed, and their radiation signature is estimated. It is suggested that plasma radiation can explain the power observed in stationary and moving type IV bursts.

  17. Systematic classification of two-loop realizations of the Weinberg operator

    Energy Technology Data Exchange (ETDEWEB)

    Sierra, D. Aristizabal; Degee, A. [IFPA, Dep. AGO, Universite de Liege,Bat B5, Sart Tilman B-4000 Liege 1 (Belgium); Dorame, L.; Hirsch, M. [AHEP Group, Instituto de Fisica Corpuscular-C.S.I.C./Universitat de Valencia,Edificio Institutos de Paterna, Apt 22085, E-46071 Valencia (Spain)

    2015-03-09

    We systematically analyze the d=5 Weinberg operator at 2-loop order. Using a diagrammatic approach, we identify two different interesting categories of neutrino mass models: (i) Genuine 2-loop models for which both, tree-level and 1-loop contributions, are guaranteed to be absent. And (ii) finite 2-loop diagrams, which correspond to the 1-loop generation of some particular vertex appearing in a given 1-loop neutrino mass model, thus being effectively 2-loop. From the large list of all possible 2-loop diagrams, the vast majority are infinite corrections to lower order neutrino mass models and only a moderately small number of diagrams fall into these two interesting classes. Moreover, all diagrams in class (i) are just variations of three basic diagrams, with examples discussed in the literature before. Similarly, we also show that class (ii) diagrams consists of only variations of these three plus two more basic diagrams. Finally, we show how our results can be consistently and readily used in order to construct two-loop neutrino mass models.

  18. Loop quantum gravity in asymptotically flat spaces

    International Nuclear Information System (INIS)

    Arnsdorf, M.

    2000-01-01

    This thesis describes applications and extensions of the loop variable approach to non-perturbative quantum gravity. The common theme of the work presented, is the need to generalise loop quantum gravity to be applicable in cases where space is asymptotically flat, and no longer compact as is usually assumed. This is important for the study of isolated gravitational systems. It also presents a natural context in which to search for the semi-classical limit, one of the main outstanding problems in loop quantum gravity. In the first part of the thesis we study how isolated gravitational systems can be attributed particle-like properties. In particular, we show how spinorial states can arise in pure loop quantum gravity if spatial topology is non-trivial, thus confirming an old conjecture of Friedman and Sorkin. Heuristically, this corresponds to the idea that we can rotate isolated regions of spatial topology relative to the environment at infinity, and that only a 4π-rotation will take us back to the original configuration. To do this we extend the standard loop quantum gravity formalism by introducing a compactification of our non-compact spatial manifold, and study the knotting of embedded graphs. The second part of the thesis takes a more systematic approach to the study of loop quantum gravity on non-compact spaces. We look for new representations of the loop algebra, which give rise to quantum theories that are inequivalent to the standard one. These theories naturally describe excitations of a fiducial background state, which is specified via the choice of its vacuum expectation values. In particular, we can choose background states that describe the geometries of non-compact manifolds. We also discuss how suitable background states can be constructed that can approximate classical phase space data, in our case holonomies along embedded paths and geometrical quantities related to areas and volumes. These states extend the notion of the weave and provide a

  19. Review article: closed-loop systems in anesthesia: is there a potential for closed-loop fluid management and hemodynamic optimization?

    Science.gov (United States)

    Rinehart, Joseph; Liu, Ngai; Alexander, Brenton; Cannesson, Maxime

    2012-01-01

    Closed-loop (automated) controllers are encountered in all aspects of modern life in applications ranging from air-conditioning to spaceflight. Although these systems are virtually ubiquitous, they are infrequently used in anesthesiology because of the complexity of physiologic systems and the difficulty in obtaining reliable and valid feedback data from the patient. Despite these challenges, closed-loop systems are being increasingly studied and improved for medical use. Two recent developments have made fluid administration a candidate for closed-loop control. First, the further description and development of dynamic predictors of fluid responsiveness provides a strong parameter for use as a control variable to guide fluid administration. Second, rapid advances in noninvasive monitoring of cardiac output and other hemodynamic variables make goal-directed therapy applicable for a wide range of patients in a variety of clinical care settings. In this article, we review the history of closed-loop controllers in clinical care, discuss the current understanding and limitations of the dynamic predictors of fluid responsiveness, and examine how these variables might be incorporated into a closed-loop fluid administration system.

  20. PG-100 helium loop in the MR reactor

    International Nuclear Information System (INIS)

    Ponomarev-Stepnoj, N.N.; Yakovlev, V.V.; Tikhonov, N.I.

    1983-01-01

    Main systems and production equipment units of PG-100 helium loop in the MR reactor are described. Possible long-term synchronizing operation of loop and reactor as well as possibility of carrying out life-time tests of spherical fuel elements and materials are shown. Serviceability of spherical fuel elements under conditions similar to the ones of HTGR-50 operation as well as high serviceability of cleanup system accepted for HTGR are verified. Due to low radiation dose the loop is operated without limits, helium losses in the loop don't exceed 0.5%/24 h, taking account of experimental gas sampling

  1. Time Optimal Synchronization Procedure and Associated Feedback Loops

    CERN Document Server

    Angoletta, Maria Elena; CERN. Geneva. ATS Department

    2016-01-01

    A procedure to increase the speed of currently used synchronization loops in a synchrotron by an order of magnitude is presented. Beams dynamics constraint imposes an upper limit on excursions in stable phase angle, and the procedure presented exploits this limit to arrive in the synchronized state from an arbitrary initial state in the fastest possible way. Detailed corrector design for beam phase loop, differential frequency loop and final synchronization loop is also presented. Finally, an overview of the synchronization methods currently deployed in some other CERN’s machines is provided, together with a brief comparison with the newly proposed time-optimal algorithm.

  2. Nonequilibrium Chromosome Looping via Molecular Slip Links

    Science.gov (United States)

    Brackley, C. A.; Johnson, J.; Michieletto, D.; Morozov, A. N.; Nicodemi, M.; Cook, P. R.; Marenduzzo, D.

    2017-09-01

    We propose a model for the formation of chromatin loops based on the diffusive sliding of molecular slip links. These mimic the behavior of molecules like cohesin, which, along with the CTCF protein, stabilize loops which contribute to organizing the genome. By combining 3D Brownian dynamics simulations and 1D exactly solvable nonequilibrium models, we show that diffusive sliding is sufficient to account for the strong bias in favor of convergent CTCF-mediated chromosome loops observed experimentally. We also find that the diffusive motion of multiple slip links along chromatin is rectified by an intriguing ratchet effect that arises if slip links bind to the chromatin at a preferred "loading site." This emergent collective behavior favors the extrusion of loops which are much larger than the ones formed by single slip links.

  3. Closed-loop Identification for Control of Linear Parameter Varying Systems

    DEFF Research Database (Denmark)

    Bendtsen, Jan Dimon; Trangbæk, Klaus

    2014-01-01

    , closed- loop system identification is more difficult than open-loop identification. In this paper we prove that the so-called Hansen Scheme, a technique known from linear time-invariant systems theory for transforming closed-loop system identification problems into open-loop-like problems, can...

  4. Synovial sarcoma mimicking benign peripheral nerve sheath tumor

    Energy Technology Data Exchange (ETDEWEB)

    Larque, Ana B.; Nielsen, G.P.; Chebib, Ivan [Massachusetts General Hospital and Harvard Medical School, Department of Pathology, Boston, MA (United States); Bredella, Miriam A. [Massachusetts General Hospital and Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2017-11-15

    To assess the radiographic and clinicopathologic features of synovial sarcoma of the nerve that were clinically or radiologically interpreted as benign peripheral nerve sheath tumor. Five patients with synovial sarcoma arising from the peripheral nerve and interpreted clinically and radiologically as peripheral nerve sheath tumors were identified. Clinicopathologic and imaging features were evaluated. There were three females and two males, ranging in age from 28 to 50 (mean 35.8) years. Most patients (4/5) complained of a mass, discomfort or pain. MR images demonstrated a heterogeneous, enhancing, soft tissue mass contiguous with the neurovascular bundle. On histologic examination, most tumors were monophasic synovial sarcoma (4/5). At the time of surgery, all tumors were noted to arise along or within a peripheral nerve. All patients were alive with no evidence of disease with median follow-up of 44 (range 32-237) months. For comparison, approximately 775 benign peripheral nerve sheath tumors of the extremities were identified during the same time period. Primary synovial sarcoma of the nerve can mimic peripheral nerve sheath tumors clinically and on imaging and should be included in the differential diagnosis for tumors arising from peripheral nerves. (orig.)

  5. Behavior of a solar collector loop during stagnation

    DEFF Research Database (Denmark)

    Chen, Ziqian; Dragsted, Janne; Furbo, Simon

    2015-01-01

    A mathematical model simulating the emptying behavior of a pressurized solar collector loop with solar collectors with a good emptying behavior is developed and validated with measured data. The calculated results are in good agreement with the measured results. The developed simulation model...... is therefore suitable to determine the behavior of a solar collector loop during stagnation. A volume ratio R, which is the ratio of the volume of the vapour in the upper pipes of the solar collector loop during stagnation and the fluid content of solar collectors, is introduced to determine the mass...... of the collector fluid pushed into the expansion vessel during stagnation, Min. A correlation function for the mass Min and the volume ratio R for solar collector loops is obtained. The function can be used to determine a suitable size of expansion vessels for solar collector loops....

  6. Automation of secondary loop operation in Indus-2 LCW plant

    International Nuclear Information System (INIS)

    Srinivas, L.; Pandey, R.M.; Yadav, R.P.; Gupta, S.; Gandhi, M.L.; Thakurta, A.C.

    2013-01-01

    Indus-2 Low Conductivity Water (LCW) plant has two loops, primary loop and secondary loop. The primary loop mainly supplies LCW to magnets, power supplies and RF systems at constant flow rate. The secondary loop extracts heat from the primary loop through heat exchangers to maintain the supply water temperature of the primary loop around a set value. The supply water temperature of the primary loop is maintained by operating the pumps and cooling towers in the secondary loop. The desired water flow rate in the secondary loop is met by the manual operation of the required number of the pumps. The automatic operation of the pumps and the cooling towers is proposed to replace the existing inefficient manual operation. It improves the operational reliability and ensures the optimum utilization of the pumps and the cooling towers. An algorithm has been developed using LabView programming to achieve optimized operation of the pumps and the cooling towers by incorporating First-In-First-Out (FIFO) logic. It also takes care of safety interlocks, and generates alarms. The program exchanges input and output signals of the plant using existing SCADA system. In this paper, the development of algorithm, its design and testing are elaborated. In the end, the results obtained thereof are discussed. (author)

  7. Autosomal mutations affecting Y chromosome loops in Drosophila melanogaster

    Directory of Open Access Journals (Sweden)

    Petrucci Romano

    2008-04-01

    Full Text Available Abstract Background The Y chromosome of Drosophila melanogaster harbors several genes required for male fertility. The genes for these fertility factors are very large in size and contain conspicuous amounts of repetitive DNA and transposons. Three of these loci (ks-1, kl-3 and kl-5 have the ability to develop giant lampbrush-like loops in primary spermatocytes, a cytological manifestation of their active state in these cells. Y-loops bind a number of non-Y encoded proteins, but the mechanisms regulating their development and their specific functions are still to be elucidated. Results Here we report the results of a screen of 726 male sterile lines to identify novel autosomal genes controlling Y-loop function. We analyzed mutant testis preparations both in vivo and by immunofluorescence using antibodies directed against Y-loop-associated proteins. This screen enabled us to isolate 17 mutations at 15 loci whose wild-type function is required for proper Y-loop morphogenesis. Six of these loci are likely to specifically control loop development, while the others display pleiotropic effects on both loops and meiotic processes such as spermiogenesis, sperm development and maturation. We also determined the map position of the mutations affecting exclusively Y-loop morphology. Conclusion Our cytological screening permitted us to identify novel genetic functions required for male spermatogenesis, some of which show pleiotropic effects. Analysis of these mutations also shows that loop development can be uncoupled from meiosis progression. These data represent a useful framework for the characterization of Y-loop development at a molecular level and for the study of the genetic control of heterochromatin.

  8. Peripheral refractive correction and automated perimetric profiles.

    Science.gov (United States)

    Wild, J M; Wood, J M; Crews, S J

    1988-06-01

    The effect of peripheral refractive error correction on the automated perimetric sensitivity profile was investigated on a sample of 10 clinically normal, experienced observers. Peripheral refractive error was determined at eccentricities of 0 degree, 20 degrees and 40 degrees along the temporal meridian of the right eye using the Canon Autoref R-1, an infra-red automated refractor, under the parametric conditions of the Octopus automated perimeter. Perimetric sensitivity was then undertaken at these eccentricities (stimulus sizes 0 and III) with and without the appropriate peripheral refractive correction using the Octopus 201 automated perimeter. Within the measurement limits of the experimental procedures employed, perimetric sensitivity was not influenced by peripheral refractive correction.

  9. Peripheral facial nerve dysfunction: CT evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Disbro, M.A.; Harnsberger, H.R.; Osborn, A.G.

    1985-06-01

    Peripheral facial nerve dysfunction may have a clinically apparent or occult cause. The authors reviewed the clinical and radiographic records of 36 patients with peripheral facial nerve dysfunction to obtain information on the location of the suspected lesion and the number, sequence, and type of radiographic evaluations performed. Inadequate clinical evaluations before computed tomography (CT) was done and unnecessary CT examinations were also noted. They have suggested a practical clinical and radiographic scheme to evaluate progressive peripheral facial dysfunction with no apparent cause. If this scheme is applied, unnecessary radiologic tests and delays in diagnosis and treatment may be avoided.

  10. Semiclassical analysis of loop quantum gravity

    International Nuclear Information System (INIS)

    Conrady, F.

    2005-01-01

    In this Ph.D. thesis, we explore and develop new methods that should help in determining an effective semiclassical description of canonical loop quantum gravity and spin foam gravity. A brief introduction to loop quantum gravity is followed by three research papers that present the results of the Ph.D. project. In the first article, we deal with the problem of time and a new proposal for implementing proper time as boundary conditions in a sum over histories: we investigate a concrete realization of this formalism for free scalar field theory. In the second article, we translate semiclassical states of linearized gravity into states of loop quantum gravity. The properties of the latter indicate how semiclassicality manifests itself in the loop framework, and how this may be exploited for doing semiclassical expansions. In the third part, we propose a new formulation of spin foam models that is fully triangulation- and background-independent: by means of a symmetry condition, we identify spin foam models whose triangulation-dependence can be naturally removed. (orig.)

  11. Semiclassical analysis of loop quantum gravity

    Energy Technology Data Exchange (ETDEWEB)

    Conrady, F.

    2005-10-17

    In this Ph.D. thesis, we explore and develop new methods that should help in determining an effective semiclassical description of canonical loop quantum gravity and spin foam gravity. A brief introduction to loop quantum gravity is followed by three research papers that present the results of the Ph.D. project. In the first article, we deal with the problem of time and a new proposal for implementing proper time as boundary conditions in a sum over histories: we investigate a concrete realization of this formalism for free scalar field theory. In the second article, we translate semiclassical states of linearized gravity into states of loop quantum gravity. The properties of the latter indicate how semiclassicality manifests itself in the loop framework, and how this may be exploited for doing semiclassical expansions. In the third part, we propose a new formulation of spin foam models that is fully triangulation- and background-independent: by means of a symmetry condition, we identify spin foam models whose triangulation-dependence can be naturally removed. (orig.)

  12. Full colour for loop amplitudes in Yang-Mills theory

    Energy Technology Data Exchange (ETDEWEB)

    Ochirov, Alexander [Higgs Centre for Theoretical Physics, School of Physics and Astronomy,The University of Edinburgh,Edinburgh EH9 3JZ, Scotland (United Kingdom); Page, Ben [Albert-Ludwigs-Universität Freiburg, Physikalisches Institut,D-79104 Freiburg (Germany)

    2017-02-20

    We present a general method to account for full colour dependence Yang-Mills amplitudes at loop level. The method fits most naturally into the framework of multi-loop integrand reduction and in a nutshell amounts to consistently retaining the colour structures of the unitarity cuts from which the integrand is gradually constructed. This technique has already been used in the recent calculation of the two-loop five-gluon amplitude in pure Yang-Mills theory with all positive helicities, (DOI: 10.1007/JHEP10(2015)064). In this note, we give a careful exposition of the method and discuss its connection to loop-level Kleiss-Kuijf relations. We also explore its implications for cancellation of nontrivial symmetry factors at two loops. As an example of its generality, we show how it applies to the three-loop case in supersymmetric Yang-Mills case.

  13. Wilson loops to 20th order numerical stochastic perturbation theory

    Energy Technology Data Exchange (ETDEWEB)

    Horsley, R. [Edinburgh Univ. (United Kingdom). School of Physics; Hotzel, G.; Perlt, H.; Schiller, A. [Leipzig Univ. (Germany). Inst. fuer Theoretische Physik; Ilgenfritz, E.M. [Humboldt-Universitaet, Berlin (Germany). Inst. fuer Physik; Joint Institute for Nuclear Research, VBLHEP, Dubna (Russian Federation); Millo, R.; Rakow, P.E.L. [Liverpool Univ. (Germany). Theoretical Physics Div.; Nakamura, Y. [RIKEN Advanced Institute for Computational Science, Kobe, Hyogo (Japan); Schierholz, G. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2012-05-15

    We calculate Wilson loops of various sizes up to 20 loops in SU(3) pure lattice gauge theory at different lattice sizes for Wilson gauge action using the technique of numerical stochastic perturbation theory. This allows us to investigate the perturbative series for various Wilson loops at high loop orders. We observe differences in the behavior of those series as function of the loop order. Up to n=20 we do not find evidence for the factorial growth of the expansion coefficients often assumed to characterize an asymptotic series. Based on the actually observed behavior we sum the series in a model parametrized by hypergeometric functions. Alternatively we estimate the total series in boosted perturbation theory using information from the first 14 loops. We introduce generalized ratios of Wilson loops of different sizes. Together with the corresponding Wilson loops from standard Monte Carlo measurements they enable us to assess their non-perturbative parts.

  14. Peripheral nerve conduits: technology update

    Science.gov (United States)

    Arslantunali, D; Dursun, T; Yucel, D; Hasirci, N; Hasirci, V

    2014-01-01

    Peripheral nerve injury is a worldwide clinical problem which could lead to loss of neuronal communication along sensory and motor nerves between the central nervous system (CNS) and the peripheral organs and impairs the quality of life of a patient. The primary requirement for the treatment of complete lesions is a tension-free, end-to-end repair. When end-to-end repair is not possible, peripheral nerve grafts or nerve conduits are used. The limited availability of autografts, and drawbacks of the allografts and xenografts like immunological reactions, forced the researchers to investigate and develop alternative approaches, mainly nerve conduits. In this review, recent information on the various types of conduit materials (made of biological and synthetic polymers) and designs (tubular, fibrous, and matrix type) are being presented. PMID:25489251

  15. Construction of the blowdown and condensation loop

    Energy Technology Data Exchange (ETDEWEB)

    Park, Choon Kyung; Song, Chul Kyung; Cho, Seok; Chun, S. Y.; Chung, Moon Ki

    1997-12-01

    The blowdown and condensation loop (B and C loop) has been constructed to get experimental data for designing the safety depressurization system (SDS) and steam sparger which are considered to implement in the Korea Next Generation Reactor (KNGR). In this report, system description on the B and C loop is given in detail, which includes the drawings and technical specification of each component, instrumentation and control system, and the operational procedures and the results of the performance testing. (author). 7 refs., 11 tabs., 48 figs.

  16. The five-gluon amplitude and one-loop integrals

    International Nuclear Information System (INIS)

    Bern, Z.; Dixon, L.; Kosower, D.A.

    1992-12-01

    We review the conventional field theory description of the string motivated technique. This technique is applied to the one-loop five-gluon amplitude. To evaluate the amplitude a general method for computing dimensionally regulated one-loop integrals is outlined including results for one-loop integrals required for the pentagon diagram and beyond. Finally, two five-gluon helicity amplitudes are given

  17. Automated one-loop calculations with GOSAM

    International Nuclear Information System (INIS)

    Cullen, Gavin; Greiner, Nicolas; Heinrich, Gudrun; Reiter, Thomas; Luisoni, Gionata

    2011-11-01

    We present the program package GoSam which is designed for the automated calculation of one-loop amplitudes for multi-particle processes in renormalisable quantum field theories. The amplitudes, which are generated in terms of Feynman diagrams, can be reduced using either D-dimensional integrand-level decomposition or tensor reduction. GoSam can be used to calculate one-loop QCD and/or electroweak corrections to Standard Model processes and offers the flexibility to link model files for theories Beyond the Standard Model. A standard interface to programs calculating real radiation is also implemented. We demonstrate the flexibility of the program by presenting examples of processes with up to six external legs attached to the loop. (orig.)

  18. Automated one-loop calculations with GOSAM

    Energy Technology Data Exchange (ETDEWEB)

    Cullen, Gavin [Edinburgh Univ. (United Kingdom). School of Physics and Astronomy; Deutsches Elektronen-Synchrotron, Zeuthen [DESY; Germany; Greiner, Nicolas [Illinois Univ., Urbana-Champaign, IL (United States). Dept. of Physics; Max-Planck-Institut fuer Physik, Muenchen (Germany); Heinrich, Gudrun; Reiter, Thomas [Max-Planck-Institut fuer Physik, Muenchen (Germany); Luisoni, Gionata [Durham Univ. (United Kingdom). Inst. for Particle Physics Phenomenology; Mastrolia, Pierpaolo [Max-Planck-Institut fuer Physik, Muenchen (Germany); Padua Univ. (Italy). Dipt. di Fisica; Ossola, Giovanni [New York City Univ., NY (United States). New York City College of Technology; New York City Univ., NY (United States). The Graduate School and University Center; Tramontano, Francesco [European Organization for Nuclear Research (CERN), Geneva (Switzerland)

    2011-11-15

    We present the program package GoSam which is designed for the automated calculation of one-loop amplitudes for multi-particle processes in renormalisable quantum field theories. The amplitudes, which are generated in terms of Feynman diagrams, can be reduced using either D-dimensional integrand-level decomposition or tensor reduction. GoSam can be used to calculate one-loop QCD and/or electroweak corrections to Standard Model processes and offers the flexibility to link model files for theories Beyond the Standard Model. A standard interface to programs calculating real radiation is also implemented. We demonstrate the flexibility of the program by presenting examples of processes with up to six external legs attached to the loop. (orig.)

  19. 3-D numerical simulations of coronal loops oscillations

    Directory of Open Access Journals (Sweden)

    M. Selwa

    2009-10-01

    Full Text Available We present numerical results of 3-D MHD model of a dipole active region field containing a loop with a higher density than its surroundings. We study different ways of excitation of vertical kink oscillations by velocity perturbation: as an initial condition, and as an impulsive excitation with a pulse of a given position, duration, and amplitude. These properties are varied in the parametric studies. We find that the amplitude of vertical kink oscillations is significantly amplified in comparison to horizontal kink oscillations for exciters located centrally (symmetrically below the loop, but not if the exciter is located a significant distance to the side of the loop. This explains why the pure vertical kink mode is so rarely observed in comparison to the horizontally polarized one. We discuss the role of curved magnetic field lines and the pulse overlapping at one of the loop's footpoints in 3-D active regions (AR's on the excitation and the damping of slow standing waves. We find that footpoint excitation becomes more efficient in 3-D curved loops than in 2-D curved arcades and that slow waves can be excited within an interval of time that is comparable to the observed one wave-period due to the combined effect of the pulse inside and outside the loop. Additionally, we study the effect of AR topology on the excitation and trapping of loop oscillations. We find that a perturbation acting directly on a single loop excites oscillations, but results in an increased leakage compared to excitation of oscillations in an AR field by an external source.

  20. 3-D numerical simulations of coronal loops oscillations

    Directory of Open Access Journals (Sweden)

    M. Selwa

    2009-10-01

    Full Text Available We present numerical results of 3-D MHD model of a dipole active region field containing a loop with a higher density than its surroundings. We study different ways of excitation of vertical kink oscillations by velocity perturbation: as an initial condition, and as an impulsive excitation with a pulse of a given position, duration, and amplitude. These properties are varied in the parametric studies. We find that the amplitude of vertical kink oscillations is significantly amplified in comparison to horizontal kink oscillations for exciters located centrally (symmetrically below the loop, but not if the exciter is located a significant distance to the side of the loop. This explains why the pure vertical kink mode is so rarely observed in comparison to the horizontally polarized one. We discuss the role of curved magnetic field lines and the pulse overlapping at one of the loop's footpoints in 3-D active regions (AR's on the excitation and the damping of slow standing waves. We find that footpoint excitation becomes more efficient in 3-D curved loops than in 2-D curved arcades and that slow waves can be excited within an interval of time that is comparable to the observed one wave-period due to the combined effect of the pulse inside and outside the loop. Additionally, we study the effect of AR topology on the excitation and trapping of loop oscillations. We find that a perturbation acting directly on a single loop excites oscillations, but results in an increased leakage compared to excitation of oscillations in an AR field by an external source.

  1. Phase transitions in single macromolecules: Loop-stretch transition versus loop adsorption transition in end-grafted polymer chains

    Science.gov (United States)

    Zhang, Shuangshuang; Qi, Shuanhu; Klushin, Leonid I.; Skvortsov, Alexander M.; Yan, Dadong; Schmid, Friederike

    2018-01-01

    We use Brownian dynamics simulations and analytical theory to compare two prominent types of single molecule transitions. One is the adsorption transition of a loop (a chain with two ends bound to an attractive substrate) driven by an attraction parameter ɛ and the other is the loop-stretch transition in a chain with one end attached to a repulsive substrate, driven by an external end-force F applied to the free end. Specifically, we compare the behavior of the respective order parameters of the transitions, i.e., the mean number of surface contacts in the case of the adsorption transition and the mean position of the chain end in the case of the loop-stretch transition. Close to the transition points, both the static behavior and the dynamic behavior of chains with different length N are very well described by a scaling ansatz with the scaling parameters (ɛ - ɛ*)Nϕ (adsorption transition) and (F - F*)Nν (loop-stretch transition), respectively, where ϕ is the crossover exponent of the adsorption transition and ν is the Flory exponent. We show that both the loop-stretch and the loop adsorption transitions provide an exceptional opportunity to construct explicit analytical expressions for the crossover functions which perfectly describe all simulation results on static properties in the finite-size scaling regime. Explicit crossover functions are based on the ansatz for the analytical form of the order parameter distributions at the respective transition points. In contrast to the close similarity in equilibrium static behavior, the dynamic relaxation at the two transitions shows qualitative differences, especially in the strongly ordered regimes. This is attributed to the fact that the surface contact dynamics in a strongly adsorbed chain is governed by local processes, whereas the end height relaxation of a strongly stretched chain involves the full spectrum of Rouse modes.

  2. PONDEROMOTIVE ACCELERATION IN CORONAL LOOPS

    International Nuclear Information System (INIS)

    Dahlburg, R. B.; Obenschain, K.; Laming, J. M.; Taylor, B. D.

    2016-01-01

    Ponderomotive acceleration has been asserted to be a cause of the first ionization potential (FIP) effect, the well-known enhancement in abundance by a factor of 3–4 over photospheric values of elements in the solar corona with FIP less than about 10 eV. It is shown here by means of numerical simulations that ponderomotive acceleration occurs in solar coronal loops, with the appropriate magnitude and direction, as a “by-product” of coronal heating. The numerical simulations are performed with the HYPERION code, which solves the fully compressible three-dimensional magnetohydrodynamic equations including nonlinear thermal conduction and optically thin radiation. Numerical simulations of coronal loops with an axial magnetic field from 0.005 to 0.02 T and lengths from 25,000 to 75,000 km are presented. In the simulations the footpoints of the axial loop magnetic field are convected by random, large-scale motions. There is a continuous formation and dissipation of field-aligned current sheets, which act to heat the loop. As a consequence of coronal magnetic reconnection, small-scale, high-speed jets form. The familiar vortex quadrupoles form at reconnection sites. Between the magnetic footpoints and the corona the reconnection flow merges with the boundary flow. It is in this region that the ponderomotive acceleration occurs. Mirroring the character of the coronal reconnection, the ponderomotive acceleration is also found to be intermittent.

  3. PONDEROMOTIVE ACCELERATION IN CORONAL LOOPS

    Energy Technology Data Exchange (ETDEWEB)

    Dahlburg, R. B.; Obenschain, K. [LCP and FD, Naval Research Laboratory, Washington, DC 20375 (United States); Laming, J. M. [Space Science Division, Naval Research Laboratory, Washington, DC 20375 (United States); Taylor, B. D. [AFRL Eglin AFB, Pensacola, FL 32542 (United States)

    2016-11-10

    Ponderomotive acceleration has been asserted to be a cause of the first ionization potential (FIP) effect, the well-known enhancement in abundance by a factor of 3–4 over photospheric values of elements in the solar corona with FIP less than about 10 eV. It is shown here by means of numerical simulations that ponderomotive acceleration occurs in solar coronal loops, with the appropriate magnitude and direction, as a “by-product” of coronal heating. The numerical simulations are performed with the HYPERION code, which solves the fully compressible three-dimensional magnetohydrodynamic equations including nonlinear thermal conduction and optically thin radiation. Numerical simulations of coronal loops with an axial magnetic field from 0.005 to 0.02 T and lengths from 25,000 to 75,000 km are presented. In the simulations the footpoints of the axial loop magnetic field are convected by random, large-scale motions. There is a continuous formation and dissipation of field-aligned current sheets, which act to heat the loop. As a consequence of coronal magnetic reconnection, small-scale, high-speed jets form. The familiar vortex quadrupoles form at reconnection sites. Between the magnetic footpoints and the corona the reconnection flow merges with the boundary flow. It is in this region that the ponderomotive acceleration occurs. Mirroring the character of the coronal reconnection, the ponderomotive acceleration is also found to be intermittent.

  4. Effect of vacancy loops on swelling of metals under irradiation

    International Nuclear Information System (INIS)

    Golubov, S.I.

    1981-01-01

    Subsequent analysis of vacancy loops formation in metals under irradiation is carried out and effect of vacancy loops on vacancy porosity is studied. Expression for quasistationary function of vacancy loops distribution according to sizes taking into consideration two mechanisms of their initiation-cascade and fluctuational ones - is obtained. It is shown that rate of vacancy absorption and interstitials by vacancy loops in quasiequilibrium state is similar and depends only on summary length of loops, for its calculations the self-coordinated procedure is formulated. For the rate of metal swelling under irradiation obtained is the expression taking into consideration the presence of vacancy loops [ru

  5. Xenon oscillation tests in four-loop PWR cores

    International Nuclear Information System (INIS)

    Aoki, Norihiko; Osaka, Kenichi; Shimada, Shoichiro; Tochihara, Hiroshi; Machii, Seigo

    1980-01-01

    The Kansai Electric Power Co.'s OHI Unit 1 and 2 are the first 4-loop PWRs in Japan which use 17 x 17 fuel assemblies and have essentially the same plant parameters. A 4-loop core has larger core radius and higher power density than those of 2- or 3-loop cores, and is less stable for Xe oscillation. It is therefore important to confirm that Xe oscillations in radial direction are sufficiently stable in a 4-loop core. Radial and axial Xe oscillation tests were performed during the startup physics tests of OHI Unit 1 and 2; Xe oscillation was induced by perturbation of control rods and the Xe effect on power distribution observed periodically. The test results show that the transverse Xe oscillation in the 4-loop core is sufficiently stable and that the agreement between the measurement and the calculated prediction is good. (author)

  6. Loop Diuretics in the Treatment of Hypertension.

    Science.gov (United States)

    Malha, Line; Mann, Samuel J

    2016-04-01

    Loop diuretics are not recommended in current hypertension guidelines largely due to the lack of outcome data. Nevertheless, they have been shown to lower blood pressure and to offer potential advantages over thiazide-type diuretics. Torsemide offers advantages of longer duration of action and once daily dosing (vs. furosemide and bumetanide) and more reliable bioavailability (vs. furosemide). Studies show that the previously employed high doses of thiazide-type diuretics lower BP more than furosemide. Loop diuretics appear to have a preferable side effect profile (less hyponatremia, hypokalemia, and possibly less glucose intolerance). Studies comparing efficacy and side effect profiles of loop diuretics with the lower, currently widely prescribed, thiazide doses are needed. Research is needed to fill gaps in knowledge and common misconceptions about loop diuretic use in hypertension and to determine their rightful place in the antihypertensive arsenal.

  7. A theory of desynchronisable closed loop system

    Directory of Open Access Journals (Sweden)

    Harsh Beohar

    2010-10-01

    Full Text Available The task of implementing a supervisory controller is non-trivial, even though different theories exist that allow automatic synthesis of these controllers in the form of automata. One of the reasons for this discord is due to the asynchronous interaction between a plant and its controller in implementations, whereas the existing supervisory control theories assume synchronous interaction. As a consequence the implementation suffer from the so-called inexact synchronisation problem. In this paper we address the issue of inexact synchronisation in a process algebraic setting, by solving a more general problem of refinement. We construct an asynchronous closed loop system by introducing a communication medium in a given synchronous closed loop system. Our goal is to find sufficient conditions under which a synchronous closed loop system is branching bisimilar to its corresponding asynchronous closed loop system.

  8. Closed-loop conductance scanning tunneling spectroscopy: demonstrating the equivalence to the open-loop alternative.

    Science.gov (United States)

    Hellenthal, Chris; Sotthewes, Kai; Siekman, Martin H; Kooij, E Stefan; Zandvliet, Harold J W

    2015-01-01

    We demonstrate the validity of using closed-loop z(V) conductance scanning tunneling spectroscopy (STS) measurements for the determination of the effective tunneling barrier by comparing them to more conventional open-loop I(z) measurements. Through the development of a numerical model, the individual contributions to the effective tunneling barrier present in these experiments, such as the work function and the presence of an image charge, are determined quantitatively. This opens up the possibility of determining tunneling barriers of both vacuum and molecular systems in an alternative and more detailed manner.

  9. Automatic parallelization of while-Loops using speculative execution

    International Nuclear Information System (INIS)

    Collard, J.F.

    1995-01-01

    Automatic parallelization of imperative sequential programs has focused on nests of for-loops. The most recent of them consist in finding an affine mapping with respect to the loop indices to simultaneously capture the temporal and spatial properties of the parallelized program. Such a mapping is usually called a open-quotes space-time transformation.close quotes This work describes an extension of these techniques to while-loops using speculative execution. We show that space-time transformations are a good framework for summing up previous restructuration techniques of while-loop, such as pipelining. Moreover, we show that these transformations can be derived and applied automatically

  10. Nanoscale dislocation shear loops at static equilibrium and finite temperature

    Science.gov (United States)

    Dang, Khanh; Capolungo, Laurent; Spearot, Douglas E.

    2017-12-01

    Atomistic simulations are used to determine the resolved shear stress necessary for equilibrium and the resulting geometry of nanoscale dislocation shear loops in Al. Dislocation loops with different sizes and shapes are created via superposition of elemental triangular dislocation displacement fields in the presence of an externally imposed shear stress. First, a bisection algorithm is developed to determine systematically the resolved shear stress necessary for equilibrium at 0 K. This approach allows for the identification of dislocation core structure and a correlation between dislocation loop size, shape and the computed shear stress for equilibrium. It is found, in agreement with predictions made by Scattergood and Bacon, that the equilibrium shape of a dislocation loop becomes more circular with increasing loop size. Second, the bisection algorithm is extended to study the influence of temperature on the resolved shear stress necessary for stability. An approach is presented to compute the effective lattice friction stress, including temperature dependence, for dislocation loops in Al. The temperature dependence of the effective lattice friction stress can be reliably computed for dislocation loops larger than 16.2 nm. However, for dislocation loops smaller than this threshold, the effective lattice friction stress shows a dislocation loop size dependence caused by significant overlap of the stress fields on the interior of the dislocation loops. Combined, static and finite temperature atomistic simulations provide essential data to parameterize discrete dislocation dynamics simulations.

  11. Iterative structure within the five-particle two-loop amplitude

    International Nuclear Information System (INIS)

    Cachazo, Freddy; Spradlin, Marcus; Volovich, Anastasia

    2006-01-01

    We find an unexpected iterative structure within the two-loop five-gluon amplitude in N=4 supersymmetric Yang-Mills theory. Specifically, we show that a subset of diagrams contributing to the full amplitude, including a two-loop pentagon-box integral with nontrivial dependence on five kinematical variables, satisfies an iterative relation in terms of one-loop scalar box diagrams. The implications of this result for the possible iterative structure of the full two-loop amplitude are discussed

  12. Sigma models and renormalization of string loops

    International Nuclear Information System (INIS)

    Tseytlin, A.A.

    1989-05-01

    An extension of the ''σ-model β-functions - string equations of motion'' correspondence to the string loop level is discussed. Special emphasis is made on how the renormalization group acts in string loops and, in particular, on the renormalizability property of the generating functional Z-circumflex for string amplitudes (related to the σ model partition function integrated over moduli). Renormalization of Z-circumflex at one and two loop order is analyzed in some detail. We also discuss an approach to renormalization based on operators of insertion of topological fixtures. (author). 70 refs

  13. A Verification Study on the Loop-Breaking Logic of FTREX

    International Nuclear Information System (INIS)

    Choi, Jong Soo

    2008-01-01

    The logical loop problem in fault tree analysis (FTA) has been solved by manually or automatically breaking their circular logics. The breaking of logical loops is one of uncertainty sources in fault tree analyses. A practical method which can verify fault tree analysis results was developed by Choi. The method has the capability to handle logical loop problems. It has been implemented in a FORTRAN program which is called VETA (Verification and Evaluation of fault Tree Analysis results) code. FTREX, a well-known fault tree quantifier developed by KAERI, has an automatic loop-breaking logic. In order to make certain of the correctness of the loop-breaking logic of FTREX, some typical trees with complex loops are developed and applied to this study. This paper presents some verification results of the loop-breaking logic tested by the VETA code

  14. Mining protein loops using a structural alphabet and statistical exceptionality

    Directory of Open Access Journals (Sweden)

    Martin Juliette

    2010-02-01

    Full Text Available Abstract Background Protein loops encompass 50% of protein residues in available three-dimensional structures. These regions are often involved in protein functions, e.g. binding site, catalytic pocket... However, the description of protein loops with conventional tools is an uneasy task. Regular secondary structures, helices and strands, have been widely studied whereas loops, because they are highly variable in terms of sequence and structure, are difficult to analyze. Due to data sparsity, long loops have rarely been systematically studied. Results We developed a simple and accurate method that allows the description and analysis of the structures of short and long loops using structural motifs without restriction on loop length. This method is based on the structural alphabet HMM-SA. HMM-SA allows the simplification of a three-dimensional protein structure into a one-dimensional string of states, where each state is a four-residue prototype fragment, called structural letter. The difficult task of the structural grouping of huge data sets is thus easily accomplished by handling structural letter strings as in conventional protein sequence analysis. We systematically extracted all seven-residue fragments in a bank of 93000 protein loops and grouped them according to the structural-letter sequence, named structural word. This approach permits a systematic analysis of loops of all sizes since we consider the structural motifs of seven residues rather than complete loops. We focused the analysis on highly recurrent words of loops (observed more than 30 times. Our study reveals that 73% of loop-lengths are covered by only 3310 highly recurrent structural words out of 28274 observed words. These structural words have low structural variability (mean RMSd of 0.85 Å. As expected, half of these motifs display a flanking-region preference but interestingly, two thirds are shared by short (less than 12 residues and long loops. Moreover, half of

  15. Mining protein loops using a structural alphabet and statistical exceptionality.

    Science.gov (United States)

    Regad, Leslie; Martin, Juliette; Nuel, Gregory; Camproux, Anne-Claude

    2010-02-04

    Protein loops encompass 50% of protein residues in available three-dimensional structures. These regions are often involved in protein functions, e.g. binding site, catalytic pocket... However, the description of protein loops with conventional tools is an uneasy task. Regular secondary structures, helices and strands, have been widely studied whereas loops, because they are highly variable in terms of sequence and structure, are difficult to analyze. Due to data sparsity, long loops have rarely been systematically studied. We developed a simple and accurate method that allows the description and analysis of the structures of short and long loops using structural motifs without restriction on loop length. This method is based on the structural alphabet HMM-SA. HMM-SA allows the simplification of a three-dimensional protein structure into a one-dimensional string of states, where each state is a four-residue prototype fragment, called structural letter. The difficult task of the structural grouping of huge data sets is thus easily accomplished by handling structural letter strings as in conventional protein sequence analysis. We systematically extracted all seven-residue fragments in a bank of 93000 protein loops and grouped them according to the structural-letter sequence, named structural word. This approach permits a systematic analysis of loops of all sizes since we consider the structural motifs of seven residues rather than complete loops. We focused the analysis on highly recurrent words of loops (observed more than 30 times). Our study reveals that 73% of loop-lengths are covered by only 3310 highly recurrent structural words out of 28274 observed words). These structural words have low structural variability (mean RMSd of 0.85 A). As expected, half of these motifs display a flanking-region preference but interestingly, two thirds are shared by short (less than 12 residues) and long loops. Moreover, half of recurrent motifs exhibit a significant level of

  16. Afferent loop syndrome: Role of sonography and CT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Ho; Lim, Jae Hoon; Ko, Young Tae [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1992-03-15

    Afferent loop syndrome(ALS) is caused by obstruction of the afferent loop after subtotal gastrectomy with Billroth II gastrojejunostomy. Prompt diagnosis of ALS is important as perforation of the loop occurs. The aim of study is to ascertain the sonography and CT to diagnose ALS. We describe the radiologic findings in ten patients with ALS. The cause of ALS, established at surgery, included cancer recurrence (n=4), internal hernia (n=4), marginal ulcer (n=1), and development of cancer at the anastomosis site (n=1). Abdominal X-ray and sonography were performed in all cases, upper GI series in five cases and computed tomography in two cases. The dilated afferent loop was detected in only two cases out often patients in retrospective review of abdominal X-ray. ALS with recurrence of cancer was diagnosed in three cases by upper GI series. Of the cases that had sonography, the afferent loop was seen in the upper abdomen crossing transversely over the midline in all ten patients. The cause of ALS were predicated on the basis of the sonograms in three of the five patients. In two cases of computed tomography, the dilated afferent loop and recurrent cancer at the remnant stomach were seen.Our experience suggests that the diagnosis of afferent syndrome can be made on the basis of the typical anatomic location and shape of the dilated bowel loop in both sonography and computed tomography.

  17. Loop equations and bootstrap methods in the lattice

    Directory of Open Access Journals (Sweden)

    Peter D. Anderson

    2017-08-01

    Full Text Available Pure gauge theories can be formulated in terms of Wilson Loops by means of the loop equation. In the large-N limit this equation closes in the expectation value of single loops. In particular, using the lattice as a regulator, it becomes a well defined equation for a discrete set of loops. In this paper we study different numerical approaches to solving this equation. Previous ideas gave good results in the strong coupling region. Here we propose an alternative method based on the observation that certain matrices ρˆ of Wilson loop expectation values are positive definite. They also have unit trace (ρˆ⪰0,Trρˆ=1, in fact they can be defined as reduced density matrices in the space of open loops after tracing over color indices and can be used to define an entropy associated with the loss of information due to such trace SWL=−Tr[ρˆln⁡ρˆ]. The condition that such matrices are positive definite allows us to study the weak coupling region which is relevant for the continuum limit. In the exactly solvable case of two dimensions this approach gives very good results by considering just a few loops. In four dimensions it gives good results in the weak coupling region and therefore is complementary to the strong coupling expansion. We compare the results with standard Monte Carlo simulations.

  18. Peripheral facial weakness (Bell's palsy).

    Science.gov (United States)

    Basić-Kes, Vanja; Dobrota, Vesna Dermanović; Cesarik, Marijan; Matovina, Lucija Zadro; Madzar, Zrinko; Zavoreo, Iris; Demarin, Vida

    2013-06-01

    Peripheral facial weakness is a facial nerve damage that results in muscle weakness on one side of the face. It may be idiopathic (Bell's palsy) or may have a detectable cause. Almost 80% of peripheral facial weakness cases are primary and the rest of them are secondary. The most frequent causes of secondary peripheral facial weakness are systemic viral infections, trauma, surgery, diabetes, local infections, tumor, immune disorders, drugs, degenerative diseases of the central nervous system, etc. The diagnosis relies upon the presence of typical signs and symptoms, blood chemistry tests, cerebrospinal fluid investigations, nerve conduction studies and neuroimaging methods (cerebral MRI, x-ray of the skull and mastoid). Treatment of secondary peripheral facial weakness is based on therapy for the underlying disorder, unlike the treatment of Bell's palsy that is controversial due to the lack of large, randomized, controlled, prospective studies. There are some indications that steroids or antiviral agents are beneficial but there are also studies that show no beneficial effect. Additional treatments include eye protection, physiotherapy, acupuncture, botulinum toxin, or surgery. Bell's palsy has a benign prognosis with complete recovery in about 80% of patients, 15% experience some mode of permanent nerve damage and severe consequences remain in 5% of patients.

  19. Dispersion relations in loop calculations

    International Nuclear Information System (INIS)

    Kniehl, B.A.

    1996-01-01

    These lecture notes give a pedagogical introduction to the use of dispersion relations in loop calculations. We first derive dispersion relations which allow us to recover the real part of a physical amplitude from the knowledge of its absorptive part along the branch cut. In perturbative calculations, the latter may be constructed by means of Cutkosky's rule, which is briefly discussed. For illustration, we apply this procedure at one loop to the photon vacuum-polarization function induced by leptons as well as to the γf anti-f vertex form factor generated by the exchange of a massive vector boson between the two fermion legs. We also show how the hadronic contribution to the photon vacuum polarization may be extracted from the total cross section of hadron production in e + e - annihilation measured as a function of energy. Finally, we outline the application of dispersive techniques at the two-loop level, considering as an example the bosonic decay width of a high-mass Higgs boson. (author)

  20. CT characteristics of peripheral organizing pneumonia

    International Nuclear Information System (INIS)

    Yang, Seong Oh; Choi, Chul Soon; Kim, Myung Joon; Lee, Kyung Soo; Choi, Hyung Sik; Jun, Young Hwan; Park, Yong Koo

    1988-01-01

    Diagnostic dilemma of persistent mass-forming parenchymal opacity in the lung periphery occurs occasionally in the realm of diagnostic radiology. Until recently, literature on the role of computed tomography in peripheral organizing pneumonia, which is difficult to differentiate from malignancy, has little been published. We experienced one case of pathologically proven organizing pneumonia diagnosed preoperatively by chest CT. When it comes to solitary peripheral mass density in the lung, we think that CT can be proved useful in the diagnosis of benign organizing pneumonia by showing regular and smoothly corrugate margin, peripheral contrast enhancement with inner low density, and air-trapping by intervening normal lung parenchyma.

  1. Laser peripheral iridoplasty for angle-closure.

    Science.gov (United States)

    Ng, Wai Siene; Ang, Ghee Soon; Azuara-Blanco, Augusto

    2012-02-15

    Angle-closure glaucoma is a leading cause of irreversible blindness in the world. Treatment is aimed at opening the anterior chamber angle and lowering the IOP with medical and/or surgical treatment (e.g. trabeculectomy, lens extraction). Laser iridotomy works by eliminating pupillary block and widens the anterior chamber angle in the majority of patients. When laser iridotomy fails to open the anterior chamber angle, laser iridoplasty may be recommended as one of the options in current standard treatment for angle-closure. Laser peripheral iridoplasty works by shrinking and pulling the peripheral iris tissue away from the trabecular meshwork. Laser peripheral iridoplasty can be used for crisis of acute angle-closure and also in non-acute situations.   To assess the effectiveness of laser peripheral iridoplasty in the treatment of narrow angles (i.e. primary angle-closure suspect), primary angle-closure (PAC) or primary angle-closure glaucoma (PACG) in non-acute situations when compared with any other intervention. In this review, angle-closure will refer to patients with narrow angles (PACs), PAC and PACG. We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2011, Issue 12), MEDLINE (January 1950 to January 2012), EMBASE (January 1980 to January 2012), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to January 2012), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). There were no date or language restrictions in the electronic searches for trials. The electronic databases were last searched on 5 January 2012. We included only randomised controlled trials (RCTs) in this review. Patients with narrow angles, PAC or PACG were eligible. We excluded studies that included only patients with acute presentations

  2. Blind Loop Syndrome

    Science.gov (United States)

    ... or scleroderma involving the small intestine History of radiation therapy to the abdomen Diabetes Diverticulosis of the small intestine Complications A blind loop can cause escalating problems, including: Poor absorption of fats. Bacteria in your small intestine break down the bile ...

  3. [Peripheral retinal degenerations--treatment recommendations].

    Science.gov (United States)

    Joussen, A M; Kirchhof, B

    2004-10-01

    This report reviews the clinical appearance of degenerative diseases of the peripheral retina in relationship to the risk of developing a rhegmatogenous retinal detachment. We present recommendations for preventive treatment in eyes at increased risk of developing retinal detachment. Retinal degenerations are common lesions involving the peripheral retina but most of them are clinically insignificant. Lattice degeneration, degenerative retinoschisis, cystic retinal tufts, and very rarely zonular traction tufts can result in rhegmatogenous retinal detachment. Therefore, these lesions have been considered for prophylactic treatment; however, adequate studies have not been performed to date. Most of the peripheral retinal degenerations may not require treatment except in rare, high-risk situations. According to current knowledge there is no higher incidence of secondary pucker or other side effects after laser coagulation. Therefore, generous laser indication is recommended if risk factors apply.

  4. Supersymmetric Regularization Two-Loop QCD Amplitudes and Coupling Shifts

    Energy Technology Data Exchange (ETDEWEB)

    Dixon, Lance

    2002-03-08

    We present a definition of the four-dimensional helicity (FDH) regularization scheme valid for two or more loops. This scheme was previously defined and utilized at one loop. It amounts to a variation on the standard 't Hooft-Veltman scheme and is designed to be compatible with the use of helicity states for ''observed'' particles. It is similar to dimensional reduction in that it maintains an equal number of bosonic and fermionic states, as required for preserving supersymmetry. Supersymmetry Ward identities relate different helicity amplitudes in supersymmetric theories. As a check that the FDH scheme preserves supersymmetry, at least through two loops, we explicitly verify a number of these identities for gluon-gluon scattering (gg {yields} gg) in supersymmetric QCD. These results also cross-check recent non-trivial two-loop calculations in ordinary QCD. Finally, we compute the two-loop shift between the FDH coupling and the standard {bar M}{bar S} coupling, {alpha}{sub s}. The FDH shift is identical to the one for dimensional reduction. The two-loop coupling shifts are then used to obtain the three-loop QCD {beta} function in the FDH and dimensional reduction schemes.

  5. Supersymmetric Regularization Two-Loop QCD Amplitudes and Coupling Shifts

    International Nuclear Information System (INIS)

    Dixon, Lance

    2002-01-01

    We present a definition of the four-dimensional helicity (FDH) regularization scheme valid for two or more loops. This scheme was previously defined and utilized at one loop. It amounts to a variation on the standard 't Hooft-Veltman scheme and is designed to be compatible with the use of helicity states for ''observed'' particles. It is similar to dimensional reduction in that it maintains an equal number of bosonic and fermionic states, as required for preserving supersymmetry. Supersymmetry Ward identities relate different helicity amplitudes in supersymmetric theories. As a check that the FDH scheme preserves supersymmetry, at least through two loops, we explicitly verify a number of these identities for gluon-gluon scattering (gg → gg) in supersymmetric QCD. These results also cross-check recent non-trivial two-loop calculations in ordinary QCD. Finally, we compute the two-loop shift between the FDH coupling and the standard MS coupling, α s . The FDH shift is identical to the one for dimensional reduction. The two-loop coupling shifts are then used to obtain the three-loop QCD β function in the FDH and dimensional reduction schemes

  6. Loop calculus for lattice gauge theories

    International Nuclear Information System (INIS)

    Gambini, R.; Leal, L.; Trias, A.; Departamento de Fisica Aplicada, Facultad de Ingenieria, Universidad Central de Venezuela, Apartado 47724, Caracas 1051, Venezuela; Departament de Matematiques, Universitat Politecnica de Catalunya, Escuela Tecnica Superior de Enginyers de Telecomunicaciones, Barcelona 08034, Spain)

    1989-01-01

    Hamiltonian calculations are performed using a loop-labeled basis where the full set of identities for the SU(N) gauge models has been incorporated. The loops are classified as clusterlike structures and the eigenvalue problem leads to a linear set of finite-difference equations easily amenable to numerical treatment. Encouraging results are reported for SU(2) at spatial dimension 2

  7. Two-loop corrections for nuclear matter in the Walecka model

    International Nuclear Information System (INIS)

    Furnstahl, R.J.; Perry, R.J.; Serot, B.D.; Department of Physics, The Ohio State University, Columbus, Ohio 43210; Physics Department and Nuclear Theory Center, Indiana University, Bloomington, Indiana 47405)

    1989-01-01

    Two-loop corrections for nuclear matter, including vacuum polarization, are calculated in the Walecka model to study the loop expansion as an approximation scheme for quantum hadrodynamics. Criteria for useful approximation schemes are discussed, and the concepts of strong and weak convergence are introduced. The two-loop corrections are evaluated first with one-loop parameters and mean fields and then by minimizing the total energy density with respect to the scalar field and refitting parameters to empirical nuclear matter saturation properties. The size and nature of the corrections indicate that the loop expansion is not convergent at two-loop order in either the strong or weak sense. Prospects for alternative approximation schemes are discussed

  8. Two-loop amplitudes and master integrals for the production of a Higgs boson via a massive quark and a scalar-quark loop

    CERN Document Server

    Anastasiou, C; Bucherer, S; Daleo, A; Kunszt, Zoltán; Anastasiou, Charalampos; Beerli, Stefan; Bucherer, Stefan; Daleo, Alejandro; Kunszt, Zoltan

    2007-01-01

    We compute all two-loop master integrals which are required for the evaluation of next-to-leading order QCD corrections in Higgs boson production via gluon fusion. Many two-loop amplitudes for 2 -> 1 processes in the Standard Model and beyond can be expressed in terms of these integrals using automated reduction techniques. These integrals also form a subset of the master integrals for more complicated 2 -> 2 amplitudes with massive propagators in the loops. As a first application, we evaluate the two-loop amplitude for Higgs boson production in gluon fusion via a massive quark. Our result is the first independent check of the calculation of Spira, Djouadi, Graudenz and Zerwas. We also present for the first time the two-loop amplitude for gg -> h via a massive squark.

  9. Fuzzy logic controllers and chaotic natural convection loops

    International Nuclear Information System (INIS)

    Theler, German

    2007-01-01

    The study of natural circulation loops is a subject of special concern for the engineering design of advanced nuclear reactors, as natural convection provides an efficient and completely passive heat removal system. However, under certain circumstances thermal-fluid-dynamical instabilities may appear, threatening the reactor safety as a whole.On the other hand, fuzzy logic controllers provide an ideal framework to approach highly non-linear control problems. In the present work, we develop a software-based fuzzy logic controller and study its application to chaotic natural convection loops.We numerically analyse the linguistic control of the loop known as the Welander problem in such conditions that, if the controller were not present, the circulation flow would be non-periodic unstable.We also design a Taka gi-Sugeno fuzzy controller based on a fuzzy model of a natural convection loop with a toroidal geometry, in order to stabilize a Lorenz-chaotic behaviour.Finally, we show experimental results obtained in a rectangular natural circulation loop [es

  10. Hybrid nodal loop metal: Unconventional magnetoresponse and material realization

    Science.gov (United States)

    Zhang, Xiaoming; Yu, Zhi-Ming; Lu, Yunhao; Sheng, Xian-Lei; Yang, Hui Ying; Yang, Shengyuan A.

    2018-03-01

    A nodal loop is formed by a band crossing along a one-dimensional closed manifold, with each point on the loop a linear nodal point in the transverse dimensions, and can be classified as type I or type II depending on the band dispersion. Here, we propose a class of nodal loops composed of both type-I and type-II points, which are hence termed as hybrid nodal loops. Based on first-principles calculations, we predict the realization of such loops in the existing electride material Ca2As . For a hybrid loop, the Fermi surface consists of coexisting electron and hole pockets that touch at isolated points for an extended range of Fermi energies, without the need for fine-tuning. This leads to unconventional magnetic responses, including the zero-field magnetic breakdown and the momentum-space Klein tunneling observable in the magnetic quantum oscillations, as well as the peculiar anisotropy in the cyclotron resonance.

  11. Efficiently computing exact geodesic loops within finite steps.

    Science.gov (United States)

    Xin, Shi-Qing; He, Ying; Fu, Chi-Wing

    2012-06-01

    Closed geodesics, or geodesic loops, are crucial to the study of differential topology and differential geometry. Although the existence and properties of closed geodesics on smooth surfaces have been widely studied in mathematics community, relatively little progress has been made on how to compute them on polygonal surfaces. Most existing algorithms simply consider the mesh as a graph and so the resultant loops are restricted only on mesh edges, which are far from the actual geodesics. This paper is the first to prove the existence and uniqueness of geodesic loop restricted on a closed face sequence; it contributes also with an efficient algorithm to iteratively evolve an initial closed path on a given mesh into an exact geodesic loop within finite steps. Our proposed algorithm takes only an O(k) space complexity and an O(mk) time complexity (experimentally), where m is the number of vertices in the region bounded by the initial loop and the resultant geodesic loop, and k is the average number of edges in the edge sequences that the evolving loop passes through. In contrast to the existing geodesic curvature flow methods which compute an approximate geodesic loop within a predefined threshold, our method is exact and can apply directly to triangular meshes without needing to solve any differential equation with a numerical solver; it can run at interactive speed, e.g., in the order of milliseconds, for a mesh with around 50K vertices, and hence, significantly outperforms existing algorithms. Actually, our algorithm could run at interactive speed even for larger meshes. Besides the complexity of the input mesh, the geometric shape could also affect the number of evolving steps, i.e., the performance. We motivate our algorithm with an interactive shape segmentation example shown later in the paper.

  12. Conformational sampling in template-free protein loop structure modeling: an overview.

    Science.gov (United States)

    Li, Yaohang

    2013-01-01

    Accurately modeling protein loops is an important step to predict three-dimensional structures as well as to understand functions of many proteins. Because of their high flexibility, modeling the three-dimensional structures of loops is difficult and is usually treated as a "mini protein folding problem" under geometric constraints. In the past decade, there has been remarkable progress in template-free loop structure modeling due to advances of computational methods as well as stably increasing number of known structures available in PDB. This mini review provides an overview on the recent computational approaches for loop structure modeling. In particular, we focus on the approaches of sampling loop conformation space, which is a critical step to obtain high resolution models in template-free methods. We review the potential energy functions for loop modeling, loop buildup mechanisms to satisfy geometric constraints, and loop conformation sampling algorithms. The recent loop modeling results are also summarized.

  13. CONFORMATIONAL SAMPLING IN TEMPLATE-FREE PROTEIN LOOP STRUCTURE MODELING: AN OVERVIEW

    Directory of Open Access Journals (Sweden)

    Yaohang Li

    2013-02-01

    Full Text Available Accurately modeling protein loops is an important step to predict three-dimensional structures as well as to understand functions of many proteins. Because of their high flexibility, modeling the three-dimensional structures of loops is difficult and is usually treated as a “mini protein folding problem” under geometric constraints. In the past decade, there has been remarkable progress in template-free loop structure modeling due to advances of computational methods as well as stably increasing number of known structures available in PDB. This mini review provides an overview on the recent computational approaches for loop structure modeling. In particular, we focus on the approaches of sampling loop conformation space, which is a critical step to obtain high resolution models in template-free methods. We review the potential energy functions for loop modeling, loop buildup mechanisms to satisfy geometric constraints, and loop conformation sampling algorithms. The recent loop modeling results are also summarized.

  14. The Diabetes Telephone Study: Design and challenges of a pragmatic cluster randomized trial to improve diabetic peripheral neuropathy treatment.

    Science.gov (United States)

    Adams, Alyce S; Bayliss, Elizabeth A; Schmittdiel, Julie A; Altschuler, Andrea; Dyer, Wendy; Neugebauer, Romain; Jaffe, Marc; Young, Joseph D; Kim, Eileen; Grant, Richard W

    2016-06-01

    is 67 (standard deviation = 12) years. The racial ethnic make-up is 56% White, 8% Asian, 13% Black or African American, and 19% Hispanic or Latino. Innovative strategies are needed to guide improvements in healthcare delivery for patients with symptomatic diabetic peripheral neuropathy. This trial aims to assess whether real-time collection and clinical feedback of patient treatment experiences can reduce patient symptom burden. Implementation of a clinical trial closely involving clinical care required researchers to partner with clinicians. If successful, this intervention provides a critical information feedback loop that would optimize diabetic peripheral neuropathy medication titration through widely available interactive voice response technology. © The Author(s) 2016.

  15. Tuning OpenACC loop execution

    KAUST Repository

    Feki, Saber

    2017-01-07

    The purpose of this chapter is to help OpenACC developer who is already familiar with the basic and essential directives to further improve his code performance by adding more descriptive clauses to OpenACC loop constructs. At the end of this chapter the reader will: • Have a better understanding of the purpose of the OpenACC loop construct and its associated clauses illustrated with use cases • Use the acquired knowledge in practice to further improve the performance of OpenACC accelerated codes

  16. Kinetics of Internal-Loop Formation in Polypeptide Chains: A Simulation Study

    Science.gov (United States)

    Doucet, Dana; Roitberg, Adrian; Hagen, Stephen J.

    2007-01-01

    The speed of simple diffusional motions, such as the formation of loops in the polypeptide chain, places one physical limit on the speed of protein folding. Many experimental studies have explored the kinetics of formation of end-to-end loops in polypeptide chains; however, protein folding more often requires the formation of contacts between interior points on the chain. One expects that, for loops of fixed contour length, interior loops will form more slowly than end-to-end loops, owing to the additional excluded volume associated with the “tails”. We estimate the magnitude of this effect by generating ensembles of randomly coiled, freely jointed chains, and then using the theory of Szabo, Schulten, and Schulten to calculate the corresponding contact formation rates for these ensembles. Adding just a few residues, to convert an end-to-end loop to an internal loop, sharply decreases the contact rate. Surprisingly, the relative change in rate increases for a longer loop; sufficiently long tails, however, actually reverse the effect and accelerate loop formation slightly. Our results show that excluded volume effects in real, full-length polypeptides may cause the rates of loop formation during folding to depart significantly from the values derived from recent loop-formation experiments on short peptides. PMID:17208979

  17. Aesthetic rehabilitation with multiple loop connectors

    Directory of Open Access Journals (Sweden)

    Ashish Kalra

    2013-01-01

    Full Text Available Patients with a missing tooth along with diastema have limited treatment options to restore the edentulous space. The use of a conventional fixed partial denture (FPD to replace the missing tooth may result in too wide anterior teeth leading to poor esthetics. The diastema resulting from the missing central incisors can be managed with implant-supported prosthesis or FPD with loop connectors. An old lady reported with chief complaints of missing upper anterior teeth due to trauma. Her past dental history revealed that she was having generalized spacing between her upper anterior teeth. Considering her esthetic requirement of maintaining the diastema between 12, 11, 22, and 21, the treatment option of 06 units porcelain fused to metal FPD from canine to canine with intermittent loop connectors between 21, 22, 11, 12 was planned. Connectors basically link different parts of FPDs. The modified FPD with loop connectors enhanced the natural appearance of the restoration, maintained the diastemas and the proper emergence profile, and preserve the remaining tooth structure of abutment teeth. This clinical report discussed a method for fabrication of a modified FPD with loop connectors to restore the wide span created by missing central incisors.

  18. Angioplasty and stent placement - peripheral arteries - discharge

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000234.htm Angioplasty and stent placement - peripheral arteries - discharge To use the sharing ... peripheral artery). You may have also had a stent placed. To perform the procedure: Your doctor inserted ...

  19. Peripheral Ulcerative Keratitis

    Science.gov (United States)

    ... oval in shape. Diagnosis A doctor's evaluation Sometimes culture The diagnosis of peripheral ulcerative keratitis is suspected when the doctor sees the affected cornea in a person who also has a severe and/or long- ...

  20. Three-loop corrections in a covariant effective field theory

    International Nuclear Information System (INIS)

    McIntire, Jeff

    2008-01-01

    Chiral effective field theories have been used with success in the study of nuclear structure. It is of interest to systematically improve these energy functionals (particularly that of quantum hadrodynamics) through the inclusion of many-body correlations. One possible source of improvement is the loop expansion. Using the techniques of Infrared Regularization, the short-range, local dynamics at each order in the loops is absorbed into the parameterization of the underlying effective Lagrangian. The remaining nonlocal, exchange correlations must be calculated explicitly. Given that the interactions of quantum hadrodynamics are relatively soft, the loop expansion may be manageable or even perturbative in nuclear matter. This work investigates the role played by the three-loop contributions to the loop expansion for quantum hadrodynamics

  1. Current control loop of 3-phase grid-connected inverter

    International Nuclear Information System (INIS)

    Jabbar, A F; Mansor, M

    2013-01-01

    This paper presents a comparative study of current control loop in 3-phase inverter which is used to control the active and reactive output power. Generally, current control loop, power control loop and phase lock-loop are the conventional parameters that can be found in an inverter system controlled by the conventional linear control type, for instance proportional (P), integral (I) and derivative (D). If the grid remains stable throughout the day, PID control can be use. However variation of magnitude, frequency, voltage dips, transient, and other related power quality issues occur in a 3-phase grid often affects the control loop. This paper aims to provide an overall review on the available current control techniques used in grid connected system.

  2. Loop quantum gravity

    International Nuclear Information System (INIS)

    Pullin, J.

    2015-01-01

    Loop quantum gravity is one of the approaches that are being studied to apply the rules of quantum mechanics to the gravitational field described by the theory of General Relativity . We present an introductory summary of the main ideas and recent results. (Author)

  3. A detailed BWR recirculation loop model for RELAP

    Energy Technology Data Exchange (ETDEWEB)

    Araiza-Martínez, Enrique, E-mail: enrique.araiza@inin.gob.mx; Ortiz-Villafuerte, Javier, E-mail: javier.ortiz@inin.gob.mx; Castillo-Durán, Rogelio, E-mail: rogelio.castillo@inin.gob.mx

    2017-01-15

    Highlights: • A new detailed BWR recirculation loop model was developed for RELAP. • All jet pumps, risers, manifold, suction and control valves, and recirculation pump are modeled. • Model is tested against data from partial blockage of two jet pumps. • For practical applications, simulation results showed good agreement with available data. - Abstract: A new detailed geometric model of the whole recirculation loop of a BWR has been developed for the code RELAP. This detailed model includes the 10 jet pumps, 5 risers, manifold, suction and control valves, and the recirculation pump, per recirculation loop. The model is tested against data from an event of partial blockage at the entrance nozzle of one jet pump in both recirculation loops. For practical applications, simulation results showed good agreement with data. Then, values of parameters considered as figure of merit (reactor power, dome pressure, core flow, among others) for this event are compared against those from the common 1 jet pump per loop model. The results show that new detailed model led to a closer prediction of the reported power change. The detailed recirculation loop model can provide more reliable boundary condition data to a CFD models for studies of, for example, flow induced vibration, wear, and crack initiation.

  4. Holonomy loops, spectral triples and quantum gravity

    DEFF Research Database (Denmark)

    Johannes, Aastrup; Grimstrup, Jesper Møller; Nest, Ryszard

    2009-01-01

    We review the motivation, construction and physical interpretation of a semi-finite spectral triple obtained through a rearrangement of central elements of loop quantum gravity. The triple is based on a countable set of oriented graphs and the algebra consists of generalized holonomy loops...

  5. Hyperacute peripheral neuropathy is a predictor of oxaliplatin-induced persistent peripheral neuropathy.

    Science.gov (United States)

    Tanishima, Hiroyuki; Tominaga, Toshiji; Kimura, Masamichi; Maeda, Tsunehiro; Shirai, Yasutsugu; Horiuchi, Tetsuya

    2017-05-01

    Chronic peripheral neuropathy is a major adverse response to oxaliplatin-containing chemotherapy regimens, but there are no established risk factors pertaining to it. We investigated the efficacy of hyperacute peripheral neuropathy (HAPN) as a predictor of oxaliplatin-induced persistent peripheral neuropathy (PPN). Forty-seven cases of stage III colorectal cancer who received adjuvant chemotherapy with oxaliplatin after curative surgery between January 2010 and August 2014 were retrospectively reviewed. HAPN was defined as acute peripheral neuropathy (APN) occurring on day 1 (≤24 h after oxaliplatin infusion) of the first cycle. PPN was defined as neuropathy lasting >1 year after oxaliplatin discontinuation. The average total dose of oxaliplatin was 625.8 mg/m 2 , and the average relative dose intensity was 66.7%. Twenty-two of the 47 patients (46.8%) had PPN and 13 (27.7%) had HAPN. Male sex, treatment for neuropathy, HAPN, and APN were significantly more frequent in patients with PPN (p = 0.013, 0.02, <0.001, and 0.023, respectively). There was no significant difference in the total oxaliplatin dose between patients with and without PPN (p = 0.061). Multivariate analyses revealed total dose of oxaliplatin and HAPN as independent predictors of PPN [p = 0.015; odds ratio (OR) = 1.005, 95% confidence interval (CI), 1.001-1.009 and p = 0.001; OR = 75.307, 5.3-1070.123, respectively]. The total dose of oxaliplatin was relatively lower in patients with HAPN than that in those without HAPN in the PPN-positive group (not significant, p = 0.068). HAPN was found to be a predictor of oxaliplatin-induced PPN.

  6. Zero point energy of renormalized Wilson loops

    International Nuclear Information System (INIS)

    Hidaka, Yoshimasa; Pisarski, Robert D.

    2009-01-01

    The quark-antiquark potential, and its associated zero point energy, can be extracted from lattice measurements of the Wilson loop. We discuss a unique prescription to renormalize the Wilson loop, for which the perturbative contribution to the zero point energy vanishes identically. A zero point energy can arise nonperturbatively, which we illustrate by considering effective string models. The nonperturbative contribution to the zero point energy vanishes in the Nambu model, but is nonzero when terms for extrinsic curvature are included. At one loop order, the nonperturbative contribution to the zero point energy is negative, regardless of the sign of the extrinsic curvature term.

  7. High Dynamic Optimized Carrier Loop Improvement for Tracking Doppler Rates

    Directory of Open Access Journals (Sweden)

    Amirhossein Fereidountabar

    2015-01-01

    Full Text Available Mathematical analysis and optimization of a carrier tracking loop are presented. Due to fast changing of the carrier frequency in some satellite systems, such as Low Earth Orbit (LEO or Global Positioning System (GPS, or some planes like Unmanned Aerial Vehicles (UAVs, high dynamic tracking loops play a very important role. In this paper an optimized tracking loop consisting of a third-order Phase Locked Loop (PLL assisted by a second-order Frequency Locked Loop (FLL for UAVs is proposed and discussed. Based on this structure an optimal loop has been designed. The main advantages of this approach are the reduction of the computation complexity and smaller phase error. The paper shows the simulation results, comparing them with a previous work.

  8. Digital limiter for a self-excited loop

    International Nuclear Information System (INIS)

    Joshi, G.; Singh, P.; Agarwal, V.; Kumar, G.

    2015-01-01

    Limiter is one of the main signal processing modules of a self-excited loop (SEL). It plays a crucial role in initiating and stabilizing the amplitude of the RF field in a free running SEL. In a recently reported implementation of a self excited loop in digital domain, the limiter has been realized at based band in the form of a feedback loop. This feedback loop stabilizes the amplitude of the RF phasor present at its input without affecting its phase. In the present work we study the suitability of this implementation of limiter through analysis and simulations. An approximate equivalent model of an SEL, incorporating the digital limiter, is created in analog domain. It is demonstrated that even in the presence for large transients, such as, at the start up of oscillations, SEL continues to exhibit smooth and predictable response. In free running mode of operation the coupling from loop oscillation frequency change to resonator field amplitude change is absent, thus avoiding instability due to electro-mechanical coupling. In the locked mode, the transmission of amplitude jitter through the limiter is far exceeded by that through the controller gain thereby keeping the behavior of the digital SEL close to its analog counterpart. (author)

  9. Studies of peripheral sensory nerves in paclitaxel-induced painful peripheral neuropathy: Evidence for mitochondrial dysfunction

    OpenAIRE

    Flatters, Sarah J.L.; Bennett, Gary J.

    2006-01-01

    Paclitaxel chemotherapy frequently induces neuropathic pain during and often persisting after therapy. The mechanisms responsible for this pain are unknown. Using a rat model of paclitaxel-induced painful peripheral neuropathy, we have performed studies to search for peripheral nerve pathology. Paclitaxel-induced mechano-allodynia and mechano-hyperalgesia were evident after a short delay, peaked at day 27 and finally resolved on day 155. Paclitaxel- and vehicle-treated rats were perfused on d...

  10. Unipedal stance testing in the assessment of peripheral neuropathy.

    Science.gov (United States)

    Hurvitz, E A; Richardson, J K; Werner, R A

    2001-02-01

    To define further the relation between unipedal stance testing and peripheral neuropathy. Prospective cohort. Electroneuromyography laboratory of a Veterans Affairs medical center and a university hospital. Ninety-two patients referred for lower extremity electrodiagnostic studies. A standardized history and physical examination designed to detect peripheral neuropathy, 3 trials of unipedal stance, and electrodiagnostic studies. Peripheral neuropathy was identified by electrodiagnostic testing in 32%. These subjects had a significantly shorter (p unipedal stance time (15.7s, longest of 3 trials) than the patients without peripheral neuropathy (37.1s). Abnormal unipedal stance time (unipedal stance time had a negative predictive value of 90%. Abnormal unipedal stance time was associated with an increased risk of having peripheral neuropathy on univariate analysis (odds ratio = 8.8, 95% confidence interval = 2.5--31), and was the only significant predictor of peripheral neuropathy in the regression model. Aspects of the neurologic examination did not add to the regression model compared with abnormal unipedal stance time. Unipedal stance testing is useful in the clinical setting both to identify and to exclude the presence of peripheral neuropathy.

  11. Robust fault detection in open loop vs. closed loop

    DEFF Research Database (Denmark)

    Niemann, Hans Henrik; Stoustrup, J.

    1997-01-01

    The robustness aspects of fault detection and isolation (FDI) for uncertain systems are considered. The FDI problem is considered in a standard problem formulation. The FDI design problem is analyzed both in the case where the control input signal is considered as a known external input signal (o...... (open loop) and when the input signal is generated by a feedback controller...

  12. Saturating representation of loop conformational fragments in structure databanks

    Directory of Open Access Journals (Sweden)

    Fiser András

    2006-07-01

    Full Text Available Abstract Background Short fragments of proteins are fundamental starting points in various structure prediction applications, such as in fragment based loop modeling methods but also in various full structure build-up procedures. The applicability and performance of these approaches depend on the availability of short fragments in structure databanks. Results We studied the representation of protein loop fragments up to 14 residues in length. All possible query fragments found in sequence databases (Sequence Space were clustered and cross referenced with available structural fragments in Protein Data Bank (Structure Space. We found that the expansion of PDB in the last few years resulted in a dense coverage of loop conformational fragments. For each loops of length 8 in the current Sequence Space there is at least one loop in Structure Space with 50% or higher sequence identity. By correlating sequence and structure clusters of loops we found that a 50% sequence identity generally guarantees structural similarity. These percentages of coverage at 50% sequence cutoff drop to 96, 94, 68, 53, 33 and 13% for loops of length 9, 10, 11, 12, 13, and 14, respectively. There is not a single loop in the current Sequence Space at any length up to 14 residues that is not matched with a conformational segment that shares at least 20% sequence identity. This minimum observed identity is 40% for loops of 12 residues or shorter and is as high as 50% for 10 residue or shorter loops. We also assessed the impact of rapidly growing sequence databanks on the estimated number of new loop conformations and found that while the number of sequentially unique sequence segments increased about six folds during the last five years there are almost no unique conformational segments among these up to 12 residues long fragments. Conclusion The results suggest that fragment based prediction approaches are not limited any more by the completeness of fragments in databanks but

  13. DNA looping by FokI: the impact of synapse geometry on loop topology at varied site orientations

    Science.gov (United States)

    Rusling, David A.; Laurens, Niels; Pernstich, Christian; Wuite, Gijs J. L.; Halford, Stephen E.

    2012-01-01

    Most restriction endonucleases, including FokI, interact with two copies of their recognition sequence before cutting DNA. On DNA with two sites they act in cis looping out the intervening DNA. While many restriction enzymes operate symmetrically at palindromic sites, FokI acts asymmetrically at a non-palindromic site. The directionality of its sequence means that two FokI sites can be bridged in either parallel or anti-parallel alignments. Here we show by biochemical and single-molecule biophysical methods that FokI aligns two recognition sites on separate DNA molecules in parallel and that the parallel arrangement holds for sites in the same DNA regardless of whether they are in inverted or repeated orientations. The parallel arrangement dictates the topology of the loop trapped between sites in cis: the loop from inverted sites has a simple 180° bend, while that with repeated sites has a convoluted 360° turn. The ability of FokI to act at asymmetric sites thus enabled us to identify the synapse geometry for sites in trans and in cis, which in turn revealed the relationship between synapse geometry and loop topology. PMID:22362745

  14. Evaluation of a Portable Collision Warning Device for Patients With Peripheral Vision Loss in an Obstacle Course.

    Science.gov (United States)

    Pundlik, Shrinivas; Tomasi, Matteo; Luo, Gang

    2015-04-01

    A pocket-sized collision warning device equipped with a video camera was developed to predict impending collisions based on time to collision rather than proximity. A study was conducted in a high-density obstacle course to evaluate the effect of the device on collision avoidance in people with peripheral field loss (PFL). The 41-meter-long loop-shaped obstacle course consisted of 46 stationary obstacles from floor to head level and oncoming pedestrians. Twenty-five patients with tunnel vision (n = 13) or hemianopia (n = 12) completed four consecutive loops with and without the device, while not using any other habitual mobility aid. Walking direction and device usage order were counterbalanced. Number of collisions and preferred percentage of walking speed (PPWS) were compared within subjects. Collisions were reduced significantly by approximately 37% (P < 0.001) with the device (floor-level obstacles were excluded because the device was not designed for them). No patient had more collisions when using the device. Although the PPWS were also reduced with the device from 52% to 49% (P = 0.053), this did not account for the lower number of collisions, as the changes in collisions and PPWS were not correlated (P = 0.516). The device may help patients with a wide range of PFL avoid collisions with high-level obstacles while barely affecting their walking speed.

  15. Design Principles for Closed Loop Supply Chains

    NARCIS (Netherlands)

    H.R. Krikke (Harold); C.P. Pappis (Costas); G.T. Tsoulfas; J.M. Bloemhof-Ruwaard (Jacqueline)

    2001-01-01

    textabstractIn this paper we study design principles for closed loop supply chains. Closed loop supply chains aim at closing material flows thereby limiting emission and residual waste, but also providing customer service at low cost. We study 'traditional' and 'new' design principles known in the

  16. High-Order Frequency-Locked Loops

    DEFF Research Database (Denmark)

    Golestan, Saeed; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2017-01-01

    In very recent years, some attempts for designing high-order frequency-locked loops (FLLs) have been made. Nevertheless, the advantages and disadvantages of these structures, particularly in comparison with a standard FLL and high-order phase-locked loops (PLLs), are rather unclear. This lack...... study, and its small-signal modeling, stability analysis, and parameter tuning are presented. Finally, to gain insight about advantages and disadvantages of high-order FLLs, a theoretical and experimental performance comparison between the designed second-order FLL and a standard FLL (first-order FLL...

  17. Perturbations in loop quantum cosmology

    International Nuclear Information System (INIS)

    Nelson, W; Agullo, I; Ashtekar, A

    2014-01-01

    The era of precision cosmology has allowed us to accurately determine many important cosmological parameters, in particular via the CMB. Confronting Loop Quantum Cosmology with these observations provides us with a powerful test of the theory. For this to be possible, we need a detailed understanding of the generation and evolution of inhomogeneous perturbations during the early, quantum gravity phase of the universe. Here, we have described how Loop Quantum Cosmology provides a completion of the inflationary paradigm, that is consistent with the observed power spectra of the CMB

  18. The free-energy cost of interaction between DNA loops.

    Science.gov (United States)

    Huang, Lifang; Liu, Peijiang; Yuan, Zhanjiang; Zhou, Tianshou; Yu, Jianshe

    2017-10-03

    From the viewpoint of thermodynamics, the formation of DNA loops and the interaction between them, which are all non-equilibrium processes, result in the change of free energy, affecting gene expression and further cell-to-cell variability as observed experimentally. However, how these processes dissipate free energy remains largely unclear. Here, by analyzing a mechanic model that maps three fundamental topologies of two interacting DNA loops into a 4-state model of gene transcription, we first show that a longer DNA loop needs more mean free energy consumption. Then, independent of the type of interacting two DNA loops (nested, side-by-side or alternating), the promotion between them always consumes less mean free energy whereas the suppression dissipates more mean free energy. More interestingly, we find that in contrast to the mechanism of direct looping between promoter and enhancer, the facilitated-tracking mechanism dissipates less mean free energy but enhances the mean mRNA expression, justifying the facilitated-tracking hypothesis, a long-standing debate in biology. Based on minimal energy principle, we thus speculate that organisms would utilize the mechanisms of loop-loop promotion and facilitated tracking to survive in complex environments. Our studies provide insights into the understanding of gene expression regulation mechanism from the view of energy consumption.

  19. Microwave emission from flaring magnetic loops

    International Nuclear Information System (INIS)

    Vlahos, L.

    1980-01-01

    The microwave emission from a flaring loop is considered. In particular the author examines the question: What will be the characteristics of the radio emission at centimeter wavelengths from a small compact flaring loop when the mechanism which pumps magnetic energy into the plasma in the form of heating and/or electron acceleration satisfies the conditions: (a) the magnetic energy is released in a small volume compared to the volume of the loop, and the rate at which magnetic energy is transformed into plasma energy is faster than the energy losses from the same volume. This causes a local enhancement of the temperature by as much as one or two orders of magnitude above the coronal temperature; (b) The bulk of the energy released goes into heating the plasma and heats primarily the electrons. (Auth.)

  20. Solar flare loops observations and interpretations

    CERN Document Server

    Huang, Guangli; Ji, Haisheng; Ning, Zongjun

    2018-01-01

    This book provides results of analysis of typical solar events, statistical analysis, the diagnostics of energetic electrons and magnetic field, as well as the global behavior of solar flaring loops such as their contraction and expansion. It pays particular attention to analyzing solar flare loops with microwave, hard X-ray, optical and EUV emissions, as well as the theories of their radiation, and electron acceleration/transport. The results concerning influence of the pitch-angle anisotropy of non-thermal electrons on their microwave and hard X-ray emissions, new spectral behaviors in X-ray and microwave bands, and results related to the contraction of flaring loops, are widely discussed in the literature of solar physics. The book is useful for graduate students and researchers in solar and space physics.

  1. A Looping-Based Model for Quenching Repression.

    Directory of Open Access Journals (Sweden)

    Yaroslav Pollak

    2017-01-01

    Full Text Available We model the regulatory role of proteins bound to looped DNA using a simulation in which dsDNA is represented as a self-avoiding chain, and proteins as spherical protrusions. We simulate long self-avoiding chains using a sequential importance sampling Monte-Carlo algorithm, and compute the probabilities for chain looping with and without a protrusion. We find that a protrusion near one of the chain's termini reduces the probability of looping, even for chains much longer than the protrusion-chain-terminus distance. This effect increases with protrusion size, and decreases with protrusion-terminus distance. The reduced probability of looping can be explained via an eclipse-like model, which provides a novel inhibitory mechanism. We test the eclipse model on two possible transcription-factor occupancy states of the D. melanogaster eve 3/7 enhancer, and show that it provides a possible explanation for the experimentally-observed eve stripe 3 and 7 expression patterns.

  2. Protection of WWER type primary loops against extreme effects

    International Nuclear Information System (INIS)

    Podrouzek, J.; Rejent, B.

    1985-01-01

    Dynamic analyses of the WWER-440 primary loops for the Mochovce nuclear power plant showed that the unprotected primary loop is very soft with a first eigenfrequency of 0.38 Hz. Protection with amortisseurs and viscous shock absorbers was compared and the viscous shock absorber in all cases proved to be more suitable. GERB viscous absorbers will be installed at the Mochovce nuclear power plant. First calculations of the dynamic resistance of the WWER-1000 primary loops for the Temelin nuclear power plant to extreme events were also made. It was shown that the unprotected primary loop is rather soft with a first eigenfrequency of 0.9 Hz, or 0.6 Hz at the pressurizer branch. It will therefore be necessary to protect the primary loops with viscous shock absorbers. (Z.M.)

  3. Conformal correlation functions in the Brownian loop soup

    Science.gov (United States)

    Camia, Federico; Gandolfi, Alberto; Kleban, Matthew

    2016-01-01

    We define and study a set of operators that compute statistical properties of the Brownian loop soup, a conformally invariant gas of random Brownian loops (Brownian paths constrained to begin and end at the same point) in two dimensions. We prove that the correlation functions of these operators have many of the properties of conformal primaries in a conformal field theory, and compute their conformal dimension. The dimensions are real and positive, but have the novel feature that they vary continuously as a periodic function of a real parameter. We comment on the relation of the Brownian loop soup to the free field, and use this relation to establish that the central charge of the loop soup is twice its intensity.

  4. Conformal correlation functions in the Brownian loop soup

    Energy Technology Data Exchange (ETDEWEB)

    Camia, Federico, E-mail: federico.camia@nyu.edu [New York University Abu Dhabi (United Arab Emirates); VU University, Amsterdam (Netherlands); Gandolfi, Alberto, E-mail: albertogandolfi@nyu.edu [New York University Abu Dhabi (United Arab Emirates); Università di Firenze (Italy); Kleban, Matthew, E-mail: kleban@nyu.edu [New York University Abu Dhabi (United Arab Emirates); Center for Cosmology and Particle Physics, Department of Physics, New York University (United States)

    2016-01-15

    We define and study a set of operators that compute statistical properties of the Brownian loop soup, a conformally invariant gas of random Brownian loops (Brownian paths constrained to begin and end at the same point) in two dimensions. We prove that the correlation functions of these operators have many of the properties of conformal primaries in a conformal field theory, and compute their conformal dimension. The dimensions are real and positive, but have the novel feature that they vary continuously as a periodic function of a real parameter. We comment on the relation of the Brownian loop soup to the free field, and use this relation to establish that the central charge of the loop soup is twice its intensity.

  5. Conformal correlation functions in the Brownian loop soup

    Directory of Open Access Journals (Sweden)

    Federico Camia

    2016-01-01

    Full Text Available We define and study a set of operators that compute statistical properties of the Brownian loop soup, a conformally invariant gas of random Brownian loops (Brownian paths constrained to begin and end at the same point in two dimensions. We prove that the correlation functions of these operators have many of the properties of conformal primaries in a conformal field theory, and compute their conformal dimension. The dimensions are real and positive, but have the novel feature that they vary continuously as a periodic function of a real parameter. We comment on the relation of the Brownian loop soup to the free field, and use this relation to establish that the central charge of the loop soup is twice its intensity.

  6. Generalized modal analysis for closed-loop piezoelectric devices

    International Nuclear Information System (INIS)

    Giraud-Audine, Christophe; Giraud, Frédéric; Amberg, Michel; Lemaire-Semail, Betty

    2015-01-01

    Stress in a piezoelectric material can be controlled by imposing an electrical field. Thanks to feedback, this electrical field can be a function of some strain-related measurement so as to confer on the piezoelectric device a closed-loop macroscopic behaviour. In this paper we address the modelling of such a system by extending the modal decomposition methods to account for the closed loop. To do so, the boundary conditions are modified to include the electrical feedback circuit, hence allowing a closed-loop modal analysis. A case study is used to illustrate the theory and to validate it. The main advantage of the method is that design issues such as the coupling factor of the device and closed-loop stability are simultaneously captured. (paper)

  7. Ground loops detection system in the RFX machine

    International Nuclear Information System (INIS)

    Bellina, F.; Pomaro, N.; Trevisan, F.

    1996-01-01

    RFX is a toroidal machine for the fusion research based on the RFP configuration. During the pulse, in any conductive loop close to the machine very strong currents can be induced, which may damage the diagnostics and the other instrumentation. To avoid loops, the earthing system of the machine is tree-shaped. However, an accidental contact between metallic earthed masses of the machine may give rise to an unwanted loop as well. An automatic system for the detection of ground loops in the earthing system has therefore been developed, which works continuously during shutdown intervals and between pulses. In the paper the design of the detection system is presented, together with the experimental results on prototypes. 4 refs., 3 figs., 1 tab

  8. Lipid-lowering drugs (statins) and peripheral neuropathy.

    Science.gov (United States)

    Emad, Mohammadreza; Arjmand, Hosein; Farpour, Hamid Reza; Kardeh, Bahareh

    2018-03-01

    Peripheral neuropathy is a disorder with often unknown causes. Some drugs, including statins, are proposed to be among the causes of peripheral neuropathy. This study aimed at evaluating this condition by electrodiagnostic study among patients who had received statins. This case-control study was conducted in Shiraz, Iran in 2015, and included 39 patients aged 35-55 who had received statins for at least 6 months, and 39 healthy matched controls. Using electrodiagnosis, the sensory and motor wave features (amplitude, latency and nerve conduction velocity) of the peripheral nerves (Median, Ulnar, Tibial, Sural, and Peroneal) were evaluated among the subjects. Data were analyzed using SPSS software and pneuropathy, there were no significant differences in any of the definitions presented for peripheral neuropathy. However, the difference was close to significance for one definition [2 abnormalities in 2 nerves (p=0.055)]. Regarding mean values of the features, significant differences were observed in two features: amplitude of the peroneal motor nerve (p=0.048) and amplitude of the sural sensory nerve (p=0.036). Since statins are widely used, awareness regarding their side-effects would lead to better treatment. Even though no significant differences were found between the groups regarding the occurrence of peripheral neuropathy, there were significant differences in amplitudes of the sural sensory response and the peroneal motor response. This indicates the involvement of peripheral nerves. Therefore, we recommend that patients and physicians should be informed about the possible symptoms of this condition.

  9. Peripheral epithelial odontogenic tumor

    International Nuclear Information System (INIS)

    Carzoglio, J.; Tancredi, N.; Capurro, S.; Ravecca, T.; Scarrone, P.

    2006-01-01

    A new case of peripheral epithelial odontogenic tumor (Pindborg tumor) is reported. It is localized in the superior right gingival region, a less frequent site, and has the histopathological features previously reported. Immunochemical studies were performed, revealing a differential positive stain to cytokeratins in tumor cells deeply seated in the tumor mass, probably related to tumoral cell heterogeneity.Interestingly, in this particular case S-100 protein positive reactivity was also detected in arborescent cells intermingled with tumoral cells, resembling Langerhans cells. Even though referred in the literature in central Pindborg tumors, no references were found about their presence in peripheral tumors, like the one that is presented here

  10. An Investigation of Loop Seal Clearings in ATLAS SBLOCA Tests

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yeonsik; Cho, Seok; Kang, Kyoungho; Park, Hyunsik; Min, Kyeongho; Choi, Namhyeon; Park, Jonggook; Kim, Bokdeuk; Choi, Kiyong [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    In most of the SBLOCA cases, the pressure of the upper-head region will increase mainly owing to the accumulated steam and water inventory in the upper-plenum. This build-up pressure acts as a suppression force to the core water level, and resultantly the core water level will decrease possibly up to and/or below the top of the active core region. Simultaneously, the downcomer water level will increase owing to the evacuated water inventory from the lower part of the core region. This unbalanced hydro-static pressure between the core and downcomer region acts as a potential pushing force to the reactor coolant pump (RCP) side intermediate leg. The potential pushing force will be increased with time to overcome the hydro-static head in the upflow intermediate leg. The unbalanced hydro-static pressure can finally be dissolved with the occurrence of the loop seal clearing. A minimum core collapsed water level, located below the elevation of the loop seal bottom leg in the ATLAS tests, is taken at this time. Since the loop seal bottom leg is located below the core top for typical PWR plants such as an APR1400, the water level depression may uncover the core upper regions until the core water level recovers with the progress of the clearing of the loop seal upflow leg. At this moment, the core temperature may increase to a peak cladding temperature (PCT) owing to an excessive core uncovery by the minimum core collapsed water level. Therefore, the loop seal clearing phenomenon is very important with respect to the PCT occurrence, which is one of the most important parameters to insure the safety of the reactor system. The loop seal clearing behavior seems to be closely related to the break location and break size. Usually, a loop seal in the break loop is cleared first, and the number of loop seal clearings is dependent on the break size. The larger the break size, the more the loop seals that are cleared. An investigation of LSC in the SBLOCA for DVI line and CL breaks

  11. Isolated and coupled superquadric loop antennas for mobile communications applications

    Science.gov (United States)

    Jensen, Michael A.; Rahmat-Samii, Yahya

    1993-01-01

    This work provides an investigation of the performance of loop antennas for use in mobile communications applications. The analysis tools developed allow for high flexibility by representing the loop antenna as a superquadric curve, which includes the case of circular, elliptical, and rectangular loops. The antenna may be in an isolated environment, located above an infinite ground plane, or placed near a finite conducting plate or box. In cases where coupled loops are used, the two loops may have arbitrary relative positions and orientations. Several design examples are included to illustrate the versatility of the analysis capabilities. The performance of coupled loops arranged in a diversity scheme is also evaluated, and it is found that high diversity gain can be achieved even when the antennas are closely spaced.

  12. Mitochondrial variability in the D-loop of four equine breeds shown by PCR-SSCP analysis

    Directory of Open Access Journals (Sweden)

    Mirol Patricia M.

    2002-01-01

    Full Text Available A fragment of 466 base pairs from a highly variable peripheral region of the mitochondrial D-loop of horses was amplified and analyzed by single stranded conformational polymorphism (SSCP. Fourteen distinct SSCP variants were detected in 100 horses belonging to four breeds (Arabian, ARB; Thoroughbred, TB; Argentinian Creole, ARC; and Peruvian Paso from Argentina, PPA. Each breed showed four to eight SSCP variants, many of which were shared between two or three of the studied breeds. Arabian horses were the most variable (eigth variants, with three variants unique to the breed. PPA and ARC showed two and one characteristic SSCP variants, respectively, while TB shared all its variants with at least one of the other breeds. An analysis based on the presence/absence of the variants revealed a closer relationship between PPA and TB, which was not completely unexpected considering the mixed ancestry of the PPA mares. The results also confirm the efficiency of SSCP to detect variability in horse mitochondrial DNA.

  13. Haemopoietic progenitor cells in human peripheral blood

    International Nuclear Information System (INIS)

    Zwaan, F.E.

    1980-01-01

    The purpose of the investigation reported is to purify haemopoietic progenitor cells from human peripheral blood using density gradient centrifugation in order to isolate a progenitor cell fraction without immunocompetent cells. The purification technique of peripheral blood flow colony forming unit culture (CFU-c) by means of density gradient centrifugation and a combined depletion of various rosettes is described. The results of several 'in vitro' characteristics of purified CFU-c suspensions and of the plasma clot diffusion chamber culture technique are presented. Irradiation studies revealed that for both human bone marrow and peripheral blood the CFU-c were less radioresistant than clusters. Elimination of monocytes (and granulocytes) from the test suspensions induced an alteration in radiosensitivity pararmeters. The results obtained with the different techniques are described by analysing peripheral progenitor cell activity in myeloproliferative disorders. (Auth.)

  14. Label-free photoacoustic microscopy of peripheral nerves

    Science.gov (United States)

    Matthews, Thomas Paul; Zhang, Chi; Yao, Da-Kang; Maslov, Konstantin; Wang, Lihong V.

    2014-01-01

    Peripheral neuropathy is a common neurological problem that affects millions of people worldwide. Diagnosis and treatment of this condition are often hindered by the difficulties in making objective, noninvasive measurements of nerve fibers. Photoacoustic microscopy (PAM) has the ability to obtain high resolution, specific images of peripheral nerves without exogenous contrast. We demonstrated the first proof-of-concept imaging of peripheral nerves using PAM. As validated by both standard histology and photoacoustic spectroscopy, the origin of photoacoustic signals is myelin, the primary source of lipids in the nerves. An extracted sciatic nerve sandwiched between two layers of chicken tissue was imaged by PAM to mimic the in vivo case. Ordered fibrous structures inside the nerve, caused by the bundles of myelin-coated axons, could be observed clearly. With further technical improvements, PAM can potentially be applied to monitor and diagnose peripheral neuropathies.

  15. Active fault diagnosis in closed-loop systems

    DEFF Research Database (Denmark)

    Niemann, Hans Henrik; Poulsen, Niels Kjølstad

    2005-01-01

    Active fault diagnosis (AFD) of parametric faults is considered in connection with closed loop feedback systems. AFD involves auxiliary signals applied on the closed loop system. A fault signature matrix is introduced in connection with AFD and it is shown that if a limited number of faults can...

  16. Peripheral Neuropathy and Nerve Compression Syndromes in Burns.

    Science.gov (United States)

    Strong, Amy L; Agarwal, Shailesh; Cederna, Paul S; Levi, Benjamin

    2017-10-01

    Peripheral neuropathy and nerve compression syndromes lead to substantial morbidity following burn injury. Patients present with pain, paresthesias, or weakness along a specific nerve distribution or experience generalized peripheral neuropathy. The symptoms manifest at various times from within one week of hospitalization to many months after wound closure. Peripheral neuropathy may be caused by vascular occlusion of vasa nervorum, inflammation, neurotoxin production leading to apoptosis, and direct destruction of nerves from the burn injury. This article discusses the natural history, diagnosis, current treatments, and future directions for potential interventions for peripheral neuropathy and nerve compression syndromes related to burn injury. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Loop calculations in the three dimensional Gribov-Zwanziger Lagrangian

    International Nuclear Information System (INIS)

    Gracey, J.A.

    2010-01-01

    The three dimensional Gribov-Zwanziger Lagrangian is analysed at one and two loops. Specifically, the two loop gap equation is evaluated and the Gribov mass is expressed in terms of the coupling constant. The one loop corrections to the propagators of all the fields are determined. It is shown that when the gap equation is satisfied the Faddeev-Popov ghost and both Bose and Grassmann localizing ghosts all enhance in the infrared limit at one loop. This verifies that the Kugo-Ojima confinement criterion holds to this order and we also show that both Grassmann ghosts are enhanced at two loops. For the Bose ghost we determine the full form of the propagator in the zero momentum limit for both the transverse and longitudinal pieces and confirm Zwanziger's recent general analysis for the low energy behaviour. We provide an alternative but equivalent version of the horizon condition expressing it as the vacuum expectation value of an operator involving only the localizing Bose ghost field. The one loop static potential is also determined. (orig.)

  18. Peripheral orbit model

    CERN Document Server

    Hara, Yasuo

    1975-01-01

    Peripheral orbit model, in which an incoming hadron is assumed to revolve in a peripheral orbit around a target hadron, is discussed. The non-diffractive parts of two-body reaction amplitudes of hadrons are expressed in terms of the radius, width an absorptivity of the orbit. The radius of the orbit is about 1 fm and the width of the orbit is determined by the range of the interaction between the hadrons. The model reproduces all available experimental data on differential cross-sections and polarizations of $K^{-}p\\to K^{-}p$ and $\\bar K^{\\circ}n$ reactions for all angles successfully. This contribution is not included in the proceedings since it will appear in Progress of Theoretical Physics Vol. 51 (1974) No 2. Any person interested in the subject may apply for reprints to the author.

  19. FMFT. Fully massive four-loop tadpoles

    Energy Technology Data Exchange (ETDEWEB)

    Pikelner, Andrey [Hamburg Univ. (Germany). 2. Inst. fuer Theoretische Physik

    2017-07-15

    We present FMFT - a package written in FORM that evaluates four-loop fully massive tadpole Feynman diagrams. It is a successor of the MATAD package that has been successfully used to calculate many renormalization group functions at three-loop order in a wide range of quantum field theories especially in the Standard Model. We describe an internal structure of the package and provide some examples of its usage.

  20. Laser welding closed-loop power control

    DEFF Research Database (Denmark)

    Bagger, Claus; Olsen, Flemming Ove

    2003-01-01

    A closed-loop control system is developed to maintain an even seam width on the root side of a laser weld by continually controlling the output laser power of a 1500 W CO2 laser.......A closed-loop control system is developed to maintain an even seam width on the root side of a laser weld by continually controlling the output laser power of a 1500 W CO2 laser....

  1. FMFT: fully massive four-loop tadpoles

    Science.gov (United States)

    Pikelner, Andrey

    2018-03-01

    We present FMFT - a package written in FORM that evaluates four-loop fully massive tadpole Feynman diagrams. It is a successor of the MATAD package that has been successfully used to calculate many renormalization group functions at three-loop order in a wide range of quantum field theories especially in the Standard Model. We describe an internal structure of the package and provide some examples of its usage.

  2. Proteins mediating DNA loops effectively block transcription.

    Science.gov (United States)

    Vörös, Zsuzsanna; Yan, Yan; Kovari, Daniel T; Finzi, Laura; Dunlap, David

    2017-07-01

    Loops are ubiquitous topological elements formed when proteins simultaneously bind to two noncontiguous DNA sites. While a loop-mediating protein may regulate initiation at a promoter, the presence of the protein at the other site may be an obstacle for RNA polymerases (RNAP) transcribing a different gene. To test whether a DNA loop alters the extent to which a protein blocks transcription, the lac repressor (LacI) was used. The outcome of in vitro transcription along templates containing two LacI operators separated by 400 bp in the presence of LacI concentrations that produced both looped and unlooped molecules was visualized with scanning force microscopy (SFM). An analysis of transcription elongation complexes, moving for 60 s at an average of 10 nt/s on unlooped DNA templates, revealed that they more often surpassed LacI bound to the lower affinity O2 operator than to the highest affinity Os operator. However, this difference was abrogated in looped DNA molecules where LacI became a strong roadblock independently of the affinity of the operator. Recordings of transcription elongation complexes, using magnetic tweezers, confirmed that they halted for several minutes upon encountering a LacI bound to a single operator. The average pause lifetime is compatible with RNAP waiting for LacI dissociation, however, the LacI open conformation visualized in the SFM images also suggests that LacI could straddle RNAP to let it pass. Independently of the mechanism by which RNAP bypasses the LacI roadblock, the data indicate that an obstacle with looped topology more effectively interferes with transcription. © 2017 The Authors Protein Science published by Wiley Periodicals, Inc. on behalf of The Protein Society.

  3. Case report of a patient with peripheral facial nerve palsy

    OpenAIRE

    Rysová, Jana

    2013-01-01

    Title of bachelor's thesis: Case report of a patient with peripheral facial nerve palsy Summary: Teoretical part of bachelor's thesis contains theoretical foundation of peripheral facial nerve palsy. Practical part of bachelor's thesis contains physiotherapeutic case report of patient with peripheral facial nerve palsy. Key words: peripheral facial nerve palsy, casuistry, rehabilitation

  4. Modeling the autonomic and metabolic effects of obstructive sleep apnea: A simulation study.

    Directory of Open Access Journals (Sweden)

    Limei eCheng

    2012-01-01

    Full Text Available Long term exposure to intermittent hypoxia and sleep fragmentation introduced by recurring obstructive sleep apnea has been linked to subsequent cardiovascular disease and Type 2 diabetes. The underlying mechanisms remain unclear, but impairment of the normal interactions among the systems that regulate autonomic and metabolic function is likely involved. We have extended an existing integrative model of respiratory, cardiovascular and sleep-wake state control, to incorporate a sub-model of glucose-insulin-fatty acid regulation. This computational model is capable of simulating the complex dynamics of cardiorespiratory control, chemoreflex and state-related control of breath-to-breath ventilation, state-related and chemoreflex control of upper airway potency, respiratory and circulatory mechanics, as well as the metabolic control of glucose insulin dynamics and its interactions with the autonomic control. The interactions between autonomic and metabolic control include the circadian regulation of epinephrine secretion, epinephrine regulation on dynamic fluctuations in glucose and free-fatty acid in plasma, metabolic coupling among tissues and organs provided by insulin and epinephrine, as well as the effect of insulin on peripheral vascular sympathetic activity. These model simulations provide insight into the relative importance of the various mechanisms that determine the acute and chronic physiological effects of sleep-disordered breathing. The model can also be used to investigate the effects of a variety of interventions, such as different glucose clamps, the intravenous glucose tolerance test and the application of continuous positive airway pressure on obstructive sleep apnea subjects. As such, this model provides the foundation on which future efforts to simulate disease progression and the long-term effects of pharmacological intervention can be based.

  5. Sodium characterization during the starting period of a sodium loop

    International Nuclear Information System (INIS)

    Lievens, F.; Parmentier, C.; Soenen, M.

    1976-01-01

    A sodium loop for analytical chemistry studies has been built by S.C.K./C.E.N. at Mol Belgium. Its first working period was used to test analytical methods, to characterize the sodium and to define the operating parameters of the loop. This report covers the working parameters of the loop, the characterization of the filling sodium and its purity evolution during the first working period of the loop

  6. Automated computation of one-loop integrals in massless theories

    International Nuclear Information System (INIS)

    Hameren, A. van; Vollinga, J.; Weinzierl, S.

    2005-01-01

    We consider one-loop tensor and scalar integrals, which occur in a massless quantum field theory, and we report on the implementation into a numerical program of an algorithm for the automated computation of these one-loop integrals. The number of external legs of the loop integrals is not restricted. All calculations are done within dimensional regularization. (orig.)

  7. Virtual velocity loop based on MEMS accelerometers for optical stabilization control system

    Science.gov (United States)

    Ren, Wei; Deng, Chao; Mao, Yao; Ren, Ge

    2017-08-01

    In the optical stabilization control system (OSCS) control system based on a charge-coupled device (CCD), stabilization performance of the line-of-sight is severely limited by the mechanical resonance and the low sampling rate of the CCD. An approach to improve the stabilization performance of the OSCS control system with load restriction based on three loops, including an acceleration loop, a virtual velocity loop, and a position loop, by using MEMS accelerometers and a CCD is proposed. The velocity signal is obtained by accelerators instead of gyro sensors. Its advantages are low power, low cost, small size, and wide measuring range. A detailed analysis is provided to show how to design the virtual velocity loop and correct virtual velocity loop drift. Experimental results show that the proposed multiloop feedback control method with virtual velocity loop in which the disturbance suppression performance is better than that of the dual loop control with only an acceleration loop and a position loop at low frequency.

  8. Peripheral involvement of the joint in seronegative spondylarthritis; Periphere Gelenkbeteiligung bei seronegativen Spondarthritiden

    Energy Technology Data Exchange (ETDEWEB)

    Lingg, G.; Soltesz, I. [Rheumazentrum Bad Kreuznach (Germany). Zentrales Roentgeninstitut

    1997-10-01

    The subjects of this contributions have been restricted to the peripheral manifestations of seronegative spondylarthrosis, for reasons of conciseness and clearness. The most frequent occurrences discussed are psoriasis arthritis and, a little bit less frequent, peripheral involvement of the joint in ancylosing spondylitis and Reiter syndrome, as well as enteropathic spondylarthrosis. (orig./AJ) [Deutsch] Als Thema dieser Veroeffentlichung wurden aus Gruenden der Kuerze und der Uebersichtlichkeit aber nur die peripheren Manifestationen der seronegativen Spondarthropathien gewaehlt. Hier wiederum haben wir es am haeufigsten mit der Psoriasisarthritis und etwas seltener mit der peripheren Gelenkbeteiligung bei der Bechterew`schen Erkrankung und der Reiter`schen Erkrankung sowie der enteropathischen Spondarthritiden zu tun. (orig./AJ)

  9. Selectivity in ligand recognition of G-quadruplex loops.

    Science.gov (United States)

    Campbell, Nancy H; Patel, Manisha; Tofa, Amina B; Ghosh, Ragina; Parkinson, Gary N; Neidle, Stephen

    2009-03-03

    A series of disubstituted acridine ligands have been cocrystallized with a bimolecular DNA G-quadruplex. The ligands have a range of cyclic amino end groups of varying size. The crystal structures show that the diagonal loop in this quadruplex results in a large cavity for these groups, in contrast to the steric constraints imposed by propeller loops in human telomeric quadruplexes. We conclude that the nature of the loop has a significant influence on ligand selectivity for particular quadruplex folds.

  10. Fermionic contributions to the three-loop static potential

    International Nuclear Information System (INIS)

    Smirnov, Alexander V.; Smirnov, Vladimir A.; Steinhauser, Matthias

    2008-01-01

    We consider the three-loop corrections to the static potential which are induced by a closed fermion loop. For the reduction of the occurring integrals a combination of the Groebner and Laporta algorithm has been used and the evaluation of the master integrals has been performed with the help of the Mellin-Barnes technique. The fermionic three-loop corrections amount to 2% of the tree-level result for top quarks, 8% for bottom quarks and 27% for the charm quark system

  11. Fermionic contributions to the three-loop static potential

    Energy Technology Data Exchange (ETDEWEB)

    Smirnov, Alexander V. [Scientific Research Computing Center, Moscow State University, 119992 Moscow (Russian Federation); Institut fuer Theoretische Teilchenphysik, Universitaet Karlsruhe (Thailand), Karlsruhe Institute of Technology (KIT), 76128 Karlsruhe (Germany); Smirnov, Vladimir A. [Nuclear Physics Institute, Moscow State University, 119992 Moscow (Russian Federation); Institut fuer Theoretische Teilchenphysik, Universitaet Karlsruhe (Thailand), Karlsruhe Institute of Technology (KIT), 76128 Karlsruhe (Germany); Steinhauser, Matthias [Institut fuer Theoretische Teilchenphysik, Universitaet Karlsruhe (Thailand), Karlsruhe Institute of Technology (KIT), 76128 Karlsruhe (Germany)], E-mail: matthias.steinhauser@uka.de

    2008-10-16

    We consider the three-loop corrections to the static potential which are induced by a closed fermion loop. For the reduction of the occurring integrals a combination of the Groebner and Laporta algorithm has been used and the evaluation of the master integrals has been performed with the help of the Mellin-Barnes technique. The fermionic three-loop corrections amount to 2% of the tree-level result for top quarks, 8% for bottom quarks and 27% for the charm quark system.

  12. Mechanical evaluation of space closure loops in Orthodontics

    OpenAIRE

    Rodrigues, Eduardo Uggeri; Maruo, Hiroshi; Guariza Filho, Odilon; Tanaka, Orlando; Camargo, Elisa Souza

    2011-01-01

    This study evaluated the mechanical performance of teardrop-shaped loops and teardrop-shaped loops with helix used in orthodontic space closure. Sixty retraction loops made with 0.019" x 0.025" stainless steel (SS) and beta-titanium (BT) wires were used. They were attached to a testing machine to measure the magnitudes of the sagittal force and the load-deflection ratio necessary for 1 mm, 2 mm and 3 mm activation. The results demonstrated that the BT alloy presented significantly smaller mea...

  13. Imaging of the peripheral vascular system

    International Nuclear Information System (INIS)

    Gould, S.A.; Pond, G.D.; Pinsky, S.; Moss, G.S.; Srikantaswamy, S.; Ryo, U.Y.

    1984-01-01

    This book is limited neither to the peripheral vascular system nor to diagnostic imaging techniques. Its 18 chapters cover nonimaging blood-flow techniques (Doppler ultrasound, plethysmography) as well as noninvasive and invasive imaging techniques (ultrasound, computed tomography, radionuclide digital-subtraction angiography, and contrast angiography). These are applied not only to the peripheral vascular system but also to the aorta and vena cava

  14. OSCILLATION OF NEWLY FORMED LOOPS AFTER MAGNETIC RECONNECTION IN THE SOLAR CHROMOSPHERE

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Shuhong [Key Laboratory of Solar Activity, National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100012 (China); Xiang, Yongyuan, E-mail: shuhongyang@nao.cas.cn [Fuxian Solar Observatory, Yunnan Observatories, Chinese Academy of Sciences, Kunming 650011 (China)

    2016-03-10

    With the high spatial and temporal resolution Hα images from the New Vacuum Solar Telescope, we focus on two groups of loops with an X-shaped configuration in the dynamic chromosphere. We find that the anti-directed loops approach each other and reconnect continually. The connectivity of the loops is changed and new loops are formed and stack together. The stacked loops are sharply bent, implying that they are greatly impacted by the magnetic tension force. When another reconnection process takes place, one new loop is formed and stacks with the previously formed ones. Meanwhile, the stacked loops retract suddenly and move toward the balance position, performing an overshoot movement, which led to an oscillation with an average period of about 45 s. The oscillation of newly formed loops after magnetic reconnection in the chromosphere is observed for the first time. We suggest that the stability of the stacked loops is destroyed due to the attachment of the last new loop and then suddenly retract under the effect of magnetic tension. Because of the retraction, another lower loop is pushed outward and performs an oscillation with a period of about 25 s. The different oscillation periods may be due to their difference in three parameters, i.e., loop length, plasma density, and magnetic field strength.

  15. Raman spectroscopic detection of peripheral nerves towards nerve-sparing surgery

    Science.gov (United States)

    Minamikawa, Takeo; Harada, Yoshinori; Takamatsu, Tetsuro

    2017-02-01

    The peripheral nervous system plays an important role in motility, sensory, and autonomic functions of the human body. Preservation of peripheral nerves in surgery, namely nerve-sparing surgery, is now promising technique to avoid functional deficits of the limbs and organs following surgery as an aspect of the improvement of quality of life of patients. Detection of peripheral nerves including myelinated and unmyelinated nerves is required for the nerve-sparing surgery; however, conventional nerve identification scheme is sometimes difficult to identify peripheral nerves due to similarity of shape and color to non-nerve tissues or its limited application to only motor peripheral nerves. To overcome these issues, we proposed a label-free detection technique of peripheral nerves by means of Raman spectroscopy. We found several fingerprints of peripheral myelinated and unmyelinated nerves by employing a modified principal component analysis of typical spectra including myelinated nerve, unmyelinated nerve, and adjacent tissues. We finally realized the sensitivity of 94.2% and the selectivity of 92.0% for peripheral nerves including myelinated and unmyelinated nerves against adjacent tissues. Although further development of an intraoperative Raman spectroscopy system is required for clinical use, our proposed approach will serve as a unique and powerful tool for peripheral nerve detection for nerve-sparing surgery in the future.

  16. Non-commutative flux representation for loop quantum gravity

    Science.gov (United States)

    Baratin, A.; Dittrich, B.; Oriti, D.; Tambornino, J.

    2011-09-01

    The Hilbert space of loop quantum gravity is usually described in terms of cylindrical functionals of the gauge connection, the electric fluxes acting as non-commuting derivation operators. It has long been believed that this non-commutativity prevents a dual flux (or triad) representation of loop quantum gravity to exist. We show here, instead, that such a representation can be explicitly defined, by means of a non-commutative Fourier transform defined on the loop gravity state space. In this dual representation, flux operators act by sstarf-multiplication and holonomy operators act by translation. We describe the gauge invariant dual states and discuss their geometrical meaning. Finally, we apply the construction to the simpler case of a U(1) gauge group and compare the resulting flux representation with the triad representation used in loop quantum cosmology.

  17. Phase-locked loops. [in analog and digital circuits communication system

    Science.gov (United States)

    Gupta, S. C.

    1975-01-01

    An attempt to systematically outline the work done in the area of phase-locked loops which are now used in modern communication system design is presented. The analog phase-locked loops are well documented in several books but discrete, analog-digital, and digital phase-locked loop work is scattered. Apart from discussing the various analysis, design, and application aspects of phase-locked loops, a number of references are given in the bibliography.

  18. Results from GRACE/SUSY at one-loop

    Indian Academy of Sciences (India)

    We report the recent development on the SUSY calculations with the help of GRACE system. GRACE/SUSY/1LOOP is the computer code which can generate Feynman diagrams in the MSSM automatically and compute one-loop amplitudes in the numerical way. We present new results of various two-body decay widths ...

  19. [Atherectomy for peripheral arterial disease].

    Science.gov (United States)

    Londero, Louise Skovgaard; Høgh, Annette Langager; Lindholt, Jes Sanddal

    2015-04-13

    Symptomatic peripheral arterial disease is managed according to national and international guidelines and the number of vascular reconstructions performed each year has increased over the past decade mainly due to an increasing frequency of endovascular procedures. Atherectomy as an alternative to the established treatment of symptomatic peripheral arterial disease has recently been analysed in a Cochrane review. In Denmark, atherectomy is not performed and so far the evidence is poor as the method is not an alternative to the established treatment in this country.

  20. Chronic obstructive pulmonary disease and peripheral neuropathy

    Directory of Open Access Journals (Sweden)

    Gupta Prem

    2006-01-01

    Full Text Available Chronic obstructive pulmonary disease (COPD is the fourth leading cause of death world-wide and a further increase in the prevalence as well as mortality of the disease is predicted for coming decades. There is now an increased appreciation for the need to build awareness regarding COPD and to help the thousands of people who suffer from this disease and die prematurely from COPD or its associated complication(s. Peripheral neuropathy in COPD has received scanty attention despite the fact that very often clinicians come across COPD patients having clinical features suggestive of peripheral neuropathy. Electrophysiological tests like nerve conduction studies are required to distinguish between axonal and demyelinating type of disorder that cannot be analyzed by clinical examination alone. However, various studies addressing peripheral neuropathy in COPD carried out so far have included patients with COPD having markedly varying baseline characteristics like severe hypoxemia, elderly patients, those with long duration of illness, etc. that are not uniform across the studies and make it difficult to interpret the results to a consistent conclusion. Almost one-third of COPD patients have clinical evidence of peripheral neuropathy and two-thirds have electrophysiological abnormalities. Some patients with no clinical indication of peripheral neuropathy do have electrophysiological deficit suggestive of peripheral neuropathy. The more frequent presentation consists of a polyneuropathy that is subclinical or with predominantly sensory signs, and the neurophysiological and pathological features of predominantly axonal neuropathy. The presumed etiopathogenic factors are multiple: chronic hypoxia, tobacco smoke, alcoholism, malnutrition and adverse effects of certain drugs.

  1. LISA Pathfinder: OPD loop characterisation

    Science.gov (United States)

    Born, Michael; LPF Collaboration

    2017-05-01

    The optical metrology system (OMS) of the LISA Pathfinder mission is measuring the distance between two free-floating test masses with unprecedented precision. One of the four OMS heterodyne interferometers reads out the phase difference between the reference and the measurement laser beam. This phase from the reference interferometer is common to all other longitudinal interferometer read outs and therefore subtracted. In addition, the phase is fed back via the digital optical pathlength difference (OPD) control loop to keep it close to zero. Here, we analyse the loop parameters and compare them to on-ground measurement results.

  2. Nerve conduction and excitability studies in peripheral nerve disorders

    DEFF Research Database (Denmark)

    Krarup, Christian; Moldovan, Mihai

    2009-01-01

    counterparts in the peripheral nervous system, in some instances without peripheral nervous system symptoms. Both hereditary and acquired demyelinating neuropathies have been studied and the effects on nerve pathophysiology have been compared with degeneration and regeneration of axons. SUMMARY: Excitability......PURPOSE OF REVIEW: The review is aimed at providing information about the role of nerve excitability studies in peripheral nerve disorders. It has been known for many years that the insight into peripheral nerve pathophysiology provided by conventional nerve conduction studies is limited. Nerve...... excitability studies are relatively novel but are acquiring an increasingly important role in the study of peripheral nerves. RECENT FINDINGS: By measuring responses in nerve that are related to nodal function (strength-duration time constant, rheobase and recovery cycle) and internodal function (threshold...

  3. Some considerations in the splitting of interstitial frank loops formed by irradiation

    International Nuclear Information System (INIS)

    Seshan, K.; Grilhe, J.; Washburn, J.

    1975-05-01

    The splitting of interstitial loops formed by irradiation is considered in detail. It is shown that they may split to form obtuse--angled single shear faults on the intersecting (111) planes. A detailed description of the splitting is given in which the interstitial Frank loop is viewed as being made up of perfect dislocation loop and two shears. The detailed description is then considered in the context of the formation of complex loops as are observed in quenching and irradiation studies. Experimentally observed geometries are explained viz, triangular loops within hexagonal ones etc. The nucleation of a DC' loop in complex interstitial loop formation is shown to be feasible. DC' has the magnitude of a perfect dislocation loop and encloses an intrinsic shear

  4. Numerical Analysis of Combined Well and Open-Closed Loops Geothermal (CWG) Systems

    Science.gov (United States)

    Park, Yu-Chul

    2016-04-01

    Open-loop geothermal heat pump (GHP) system and closed-loop heat pump systems have been used in Korea to reduce emission of greenhouse gases such as carbon dioxide (CO2). The GHP systems have the pros and cons, for example, the open-loop GHP system is good energy-efficient and the closed-loop GHP system requires minimum maintenance costs. The open-loop GHP system can be used practically only with large amount of groundwater supply. The closed-loop GHP system can be used with high costs of initial installation. The performance and efficiency of the GHP system depend on the characteristics of the GHP system itself in addition to the geologic conditions. To overcome the cons of open-loop or closed-loop GHP system, the combined well and open-closed loops geothermal (CWG) system was designed. The open-loop GHP system is surrounded with closed-loop GHP systems in the CWG system. The geothermal energy in closed-loop GHP systems is supplied by the groundwater pumped by the open-loop GHP system. In this study, 2 different types of the CWG systems (small aperture hybrid CWG system and large aperture CWG system) are estimated using numerical simulation models in the aspect of energy efficiency. This work was supported by the New & Renewable Energy Core Technology Program of the Korea Institute of Energy Technology Evaluation and Planning (KETEP), granted financial resource from the Ministry of Trade, Industry & Energy, Republic of Korea. (No.20153030111120).

  5. Coronal Loops: Evolving Beyond the Isothermal Approximation

    Science.gov (United States)

    Schmelz, J. T.; Cirtain, J. W.; Allen, J. D.

    2002-05-01

    Are coronal loops isothermal? A controversy over this question has arisen recently because different investigators using different techniques have obtained very different answers. Analysis of SOHO-EIT and TRACE data using narrowband filter ratios to obtain temperature maps has produced several key publications that suggest that coronal loops may be isothermal. We have constructed a multi-thermal distribution for several pixels along a relatively isolated coronal loop on the southwest limb of the solar disk using spectral line data from SOHO-CDS taken on 1998 Apr 20. These distributions are clearly inconsistent with isothermal plasma along either the line of sight or the length of the loop, and suggested rather that the temperature increases from the footpoints to the loop top. We speculated originally that these differences could be attributed to pixel size -- CDS pixels are larger, and more `contaminating' material would be expected along the line of sight. To test this idea, we used CDS iron line ratios from our data set to mimic the isothermal results from the narrowband filter instruments. These ratios indicated that the temperature gradient along the loop was flat, despite the fact that a more complete analysis of the same data showed this result to be false! The CDS pixel size was not the cause of the discrepancy; rather, the problem lies with the isothermal approximation used in EIT and TRACE analysis. These results should serve as a strong warning to anyone using this simplistic method to obtain temperature. This warning is echoed on the EIT web page: ``Danger! Enter at your own risk!'' In other words, values for temperature may be found, but they may have nothing to do with physical reality. Solar physics research at the University of Memphis is supported by NASA grant NAG5-9783. This research was funded in part by the NASA/TRACE MODA grant for Montana State University.

  6. HEATING OF FLARE LOOPS WITH OBSERVATIONALLY CONSTRAINED HEATING FUNCTIONS

    Energy Technology Data Exchange (ETDEWEB)

    Qiu Jiong; Liu Wenjuan; Longcope, Dana W. [Department of Physics, Montana State University, Bozeman, MT 59717-3840 (United States)

    2012-06-20

    We analyze high-cadence high-resolution observations of a C3.2 flare obtained by AIA/SDO on 2010 August 1. The flare is a long-duration event with soft X-ray and EUV radiation lasting for over 4 hr. Analysis suggests that magnetic reconnection and formation of new loops continue for more than 2 hr. Furthermore, the UV 1600 Angstrom-Sign observations show that each of the individual pixels at the feet of flare loops is brightened instantaneously with a timescale of a few minutes, and decays over a much longer timescale of more than 30 minutes. We use these spatially resolved UV light curves during the rise phase to construct empirical heating functions for individual flare loops, and model heating of coronal plasmas in these loops. The total coronal radiation of these flare loops are compared with soft X-ray and EUV radiation fluxes measured by GOES and AIA. This study presents a method to observationally infer heating functions in numerous flare loops that are formed and heated sequentially by reconnection throughout the flare, and provides a very useful constraint to coronal heating models.

  7. Concentration and length dependence of DNA looping in transcriptional regulation.

    Directory of Open Access Journals (Sweden)

    Lin Han

    2009-05-01

    Full Text Available In many cases, transcriptional regulation involves the binding of transcription factors at sites on the DNA that are not immediately adjacent to the promoter of interest. This action at a distance is often mediated by the formation of DNA loops: Binding at two or more sites on the DNA results in the formation of a loop, which can bring the transcription factor into the immediate neighborhood of the relevant promoter. These processes are important in settings ranging from the historic bacterial examples (bacterial metabolism and the lytic-lysogeny decision in bacteriophage, to the modern concept of gene regulation to regulatory processes central to pattern formation during development of multicellular organisms. Though there have been a variety of insights into the combinatorial aspects of transcriptional control, the mechanism of DNA looping as an agent of combinatorial control in both prokaryotes and eukaryotes remains unclear. We use single-molecule techniques to dissect DNA looping in the lac operon. In particular, we measure the propensity for DNA looping by the Lac repressor as a function of the concentration of repressor protein and as a function of the distance between repressor binding sites. As with earlier single-molecule studies, we find (at least two distinct looped states and demonstrate that the presence of these two states depends both upon the concentration of repressor protein and the distance between the two repressor binding sites. We find that loops form even at interoperator spacings considerably shorter than the DNA persistence length, without the intervention of any other proteins to prebend the DNA. The concentration measurements also permit us to use a simple statistical mechanical model of DNA loop formation to determine the free energy of DNA looping, or equivalently, the for looping.

  8. Loop residues and catalysis in OMP synthase

    DEFF Research Database (Denmark)

    Wang, Gary P.; Hansen, Michael Riis; Grubmeyer, Charles

    2012-01-01

    binding of OMP or PRPP in binary complexes was affected little by loop mutation, suggesting that the energetics of ground-state binding have little contribution from the catalytic loop, or that a favorable binding energy is offset by costs of loop reorganization. Pre-steady-state kinetics for mutants...... values for all four substrate molecules. The 20% (i.e., 1.20) intrinsic [1?-3H]OMP kinetic isotope effect (KIE) for WT is masked because of high forward and reverse commitment factors. K103A failed to express intrinsic KIEs fully (1.095 ± 0.013). In contrast, H105A, which has a smaller catalytic lesion...... (preceding paper in this issue, DOI 10.1021/bi300083p)]. The full expression of KIEs by H105A and E107A may result from a less secure closure of the catalytic loop. The lower level of expression of the KIE by K103A suggests that in these mutant proteins the major barrier to catalysis is successful closure...

  9. Peripheral Nervous System Manifestations in Systemic Autoimmune Diseases

    OpenAIRE

    COJOCARU, Inimioara Mihaela; COJOCARU, Manole; SILOSI, Isabela; VRABIE, Camelia Doina

    2014-01-01

    The peripheral nervous system refers to parts of the nervous system outside the brain and spinal cord. Systemic autoimmune diseases can affect both the central and peripheral nervous systems in a myriad of ways and through a heterogeneous number of mechanisms leading to many different clinical manifestations. As a result, neurological complications of these disorders can result in significant morbidity and mortality. The most common complication of peripheral nervous system (PNS) involvement ...

  10. Passive Scalar Evolution in Peripheral Region

    OpenAIRE

    Lebedev, V. V.; Turitsyn, K. S.

    2003-01-01

    We consider evolution of a passive scalar (concentration of pollutants or temperature) in a chaotic (turbulent) flow. A universal asymptotic behavior of the passive scalar decay (homogenization) related to peripheral regions (near walls) is established. The passive scalar moments and its pair correlation function in the peripheral region are analyzed. A special case investigated in our paper is the passive scalar decay along a pipe.

  11. The radiation safety assessment of the heating loop of district heating reactors

    International Nuclear Information System (INIS)

    Liu Yuanzhong

    1993-01-01

    The district heating reactors are used to supply heating to the houses in cities. The concerned problems are whether the radioactive materials reach the heated houses through heating loop, and whether the safety of the dwellers can be ensured. In order to prevent radioactive materials getting into the heated houses, the district heating reactors have three loops, namely, primary loop, intermediate loop, and heating loop. In the paper, the measures of preventing radioactive materials getting into the heating loop are presented, and the possible sources of the radioactivity in the water of the intermediate loop and the heating loop are given. The regulatory aim limit of radioactive concentration in the water of the intermediate loop is put forward, which is 18.5 Bq/l. Assuming that specific radioactivity of the water of contaminated intermediate loop is up to 18.5 Bq/l, the maximum concentration of radionuclides in water of the heating loop is calculated for the normal operation and the accident of district heating reactor. The results show that the maximum possible concentration is 5.7 x 10 -3 Bq/l. The radiation safety assessment of the heating loop is made out. The conclusions are that the district heating reactors do not bring any harmful impact to the dwellers, and the safety of the dwellers can be safeguarded completely

  12. Online control loop tuning in Pickering Nuclear Generating Stations

    International Nuclear Information System (INIS)

    Yu, K.X.; Harrington, S.

    2008-01-01

    Most analog controllers in the Pickering B Nuclear Generating Stations adopted PID control scheme. In replacing the analog controllers with digital controllers, the PID control strategies, including the original tuning parameters were retained. The replacement strategy resulted in minimum effort on control loop tuning. In a few cases, however, it was found during commissioning that control loop tuning was required as a result of poor control loop performance, typically due to slow response and controlled process oscillation. Several factors are accounted for the necessities of control loop re-tuning. Our experience in commissioning the digital controllers showed that online control tuning posted some challenges in nuclear power plant. (author)

  13. Technical specification of HANARO fuel test loop

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. Y

    1998-03-01

    The design and installation of the irradiation test facility for verification test of the fuel performance are very important in connection with maximization of the utilization of HANARO. HANARO fuel test loop was designed in accordance with the same code and standards of nuclear power plant because HANARO FTL will be operated the high pressure and temperature same as nuclear power plant operation conditions. The objective of this study is to confirm the operation limit, safety limit, operation condition and checking points of HANARO fuel test loop. This results will become guidances for the planning of irradiation testing and operation of HANARO fuel test loop. (author). 13 refs., 13 tabs., 8 figs.

  14. Automated one-loop calculations with GoSam

    International Nuclear Information System (INIS)

    Cullen, Gavin; Greiner, Nicolas; Heinrich, Gudrun; Reiter, Thomas; Luisoni, Gionata; Mastrolia, Pierpaolo; Ossola, Giovanni; Tramontano, Francesco

    2012-01-01

    We present the program package GoSam which is designed for the automated calculation of one-loop amplitudes for multi-particle processes in renormalisable quantum field theories. The amplitudes, which are generated in terms of Feynman diagrams, can be reduced using either D-dimensional integrand-level decomposition or tensor reduction. GoSam can be used to calculate one-loop QCD and/or electroweak corrections to Standard Model processes and offers the flexibility to link model files for theories Beyond the Standard Model. A standard interface to programs calculating real radiation is also implemented. We demonstrate the flexibility of the program by presenting examples of processes with up to six external legs attached to the loop. (orig.)

  15. Automated One-Loop Calculations with GoSam

    CERN Document Server

    Cullen, Gavin; Heinrich, Gudrun; Luisoni, Gionata; Mastrolia, Pierpaolo; Ossola, Giovanni; Reiter, Thomas; Tramontano, Francesco

    2012-01-01

    We present the program package GoSam which is designed for the automated calculation of one-loop amplitudes for multi-particle processes in renormalisable quantum field theories. The amplitudes, which are generated in terms of Feynman diagrams, can be reduced using either D-dimensional integrand-level decomposition or tensor reduction. GoSam can be used to calculate one-loop QCD and/or electroweak corrections to Standard Model processes and offers the flexibility to link model files for theories Beyond the Standard Model. A standard interface to programs calculating real radiation is also implemented. We demonstrate the flexibility of the program by presenting examples of processes with up to six external legs attached to the loop.

  16. An exact method for solving logical loops in reliability analysis

    International Nuclear Information System (INIS)

    Matsuoka, Takeshi

    2009-01-01

    This paper presents an exact method for solving logical loops in reliability analysis. The systems that include logical loops are usually described by simultaneous Boolean equations. First, present a basic rule of solving simultaneous Boolean equations. Next, show the analysis procedures for three-component system with external supports. Third, more detailed discussions are given for the establishment of logical loop relation. Finally, take up two typical structures which include more than one logical loop. Their analysis results and corresponding GO-FLOW charts are given. The proposed analytical method is applicable to loop structures that can be described by simultaneous Boolean equations, and it is very useful in evaluating the reliability of complex engineering systems.

  17. All-loop Mondrian diagrammatics and 4-particle amplituhedron

    Science.gov (United States)

    An, Yang; Li, Yi; Li, Zhinan; Rao, Junjie

    2018-06-01

    Based on 1712.09990 which handles the 4-particle amplituhedron at 3-loop, we have found an extremely simple pattern, yet far more non-trivial than one might naturally expect: the all-loop Mondrian diagrammatics. By further simplifying and rephrasing the key relation of positivity in the amplituhedron setting, remarkably, we find a completeness relation unifying all diagrams of the Mondrian types for the 4-particle integrand of planar N = 4 SYM to all loop orders, each of which can be mapped to a simple product following a few plain rules designed for this relation. The explicit examples we investigate span from 3-loop to 7-loop order, and based on them, we classify the basic patterns of Mondrian diagrams into four types: the ladder, cross, brick-wall and spiral patterns. Interestingly, for some special combinations of ordered subspaces (a concept defined in the previous work), we find failed exceptions of the completeness relation which are called "anomalies", nevertheless, they substantially give hints on the all-loop recursive proof of this relation. These investigations are closely related to the combinatoric knowledge of separable permutations and Schröder numbers, and go even further from a diagrammatic perspective. For physical relevance, we need to further consider dual conformal invariance for two basic diagrammatic patterns to correct the numerator for a local integrand involving one or both of such patterns, while the denominator encoding its pole structure and also the sign factor, are already fixed by rules of the completeness relation. With this extra treatment to ensure the integrals are dual conformally invariant, each Mondrian diagram can be exactly translated to its corresponding physical loop integrand after being summed over all ordered subspaces that admit it.

  18. Electron contribution to the muon anomalous magnetic moment at four loops

    International Nuclear Information System (INIS)

    Kurz, Alexander; Liu, Tao; Smirnov, Alexander V.; Smirnov, Vladimir A.; Humboldt-Universitaet, Berlin; Humboldt-Universitaet, Berlin; Steinhauser, Matthias

    2016-02-01

    We present results for the QED contributions to the anomalous magnetic moment of the muon containing closed electron loops. The main focus is on perturbative corrections at four-loop order where the external photon couples to the external muon. Furthermore, all four-loop contributions involving simultaneously a closed electron and tau loop are computed. In combination with our recent results on the light-by-light-type corrections the complete four-loop electron-loop contribution to the anomalous magnetic moment of the muon has been obtained with an independent calculation. Our calculation is based on an asymptotic expansion in the ratio of the electron and the muon mass and shows the importance of higher order terms in this ratio. We perform a detailed comparison with results available in the literature and find good numerical agreement. As a by-product we present analytic results for the on-shell muon mass and wave function renormalization constants at three-loop order including massive closed electron and tau loops, which we also calculated using the method of asymptotic expansion.

  19. The Synthesis of a Hardware Scheduler for Non-Manifest Loops

    NARCIS (Netherlands)

    Mansour, O.; Molenkamp, Egbert; Krol, Th.

    This paper addresses the hardware implementation of a dynamic scheduler for non-manifest data dependent periodic loops. Static scheduling techniques which are known to give near optimal scheduling-solutions for manifest loops, fail at scheduling non-manifest loops, since they lack the run time

  20. VICTORIA Class Submarine Human-in-the-Loop Experimentation Plan

    Science.gov (United States)

    2014-06-01

    1472G. VICTORIA Class Submarine Human-in-the-Loop Experimentation Plan and Preliminary Results © Her Majesty the Queen in Right of...19 th International Command and Control Research and Technology Symposium Title: VICTORIA Class Submarine Human-in-the-Loop...TYPE 3. DATES COVERED 00-00-2014 to 00-00-2014 4. TITLE AND SUBTITLE VICTORIA Class Submarine Human-in-the-Loop Experimentation Plan 5a. CONTRACT

  1. The QED vacuum polarization function at four loops and the anomalous magnetic moment at five loops

    International Nuclear Information System (INIS)

    Baikov, P.

    2013-07-01

    The anomalous moment of the muon is one of the most fundamental observables. It has been measured experimentally with a very high precision and on theory side the contributions from perturbative QED have been calculated up to five-loop level by numerical methods. Contributions to the muon anomalous magnetic moment from certain diagram classes are also accessible by alternative methods. In this paper we present the evaluation of contributions to the QCD corrections due to insertions of the vacuum polarization function at five-loop level.

  2. The QED vacuum polarization function at four loops and the anomalous magnetic moment at five loops

    Energy Technology Data Exchange (ETDEWEB)

    Baikov, P. [Moscow State Univ. (Russian Federation). D.V. Skobeltsyn Inst. of Nuclear Physics; Maier, A. [Technische Univ. Muenchen, Garching (Germany). Physics Dept. T31; Marquard, P. [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany)

    2013-07-15

    The anomalous moment of the muon is one of the most fundamental observables. It has been measured experimentally with a very high precision and on theory side the contributions from perturbative QED have been calculated up to five-loop level by numerical methods. Contributions to the muon anomalous magnetic moment from certain diagram classes are also accessible by alternative methods. In this paper we present the evaluation of contributions to the QCD corrections due to insertions of the vacuum polarization function at five-loop level.

  3. Pemakaian Crown Loop dan Band Loop di Rahang Bawah Anak Usia Enam Tahun (Laporan Kasus

    Directory of Open Access Journals (Sweden)

    Rivi Isabela

    2015-11-01

    Full Text Available The function of space maintainer is to preserve arch length following the premature loss of a primary teeth. Early loss of primary tooth may compromise the eruption of succedaneous teeth if there is a reduction in the arch length. The Band and Crown Loop are used to maintain the loss of primary molar. The report describe a 6 year old girl who has premature loss of second left mandibular primary molar and first right mandibular primary molar treated using crown and band loop space maintainer. The patient still has mastication function from other posterior primary teeth.

  4. Concepts of self-acting circulation loops for downward heat transfer (reverse thermosiphons)

    International Nuclear Information System (INIS)

    Dobriansky, Y.

    2011-01-01

    This paper reviews the scientific and technical knowledge related to general self-acting flow loops (thermosiphons and heat pipes) that transmit heat upwards and self-acting reverse flow loops that transmit heat downwards. This paper classifies the heat and mass transfer processes that take place in general flow loops and analyses the nomenclature applied in the literature. It also presents the principles of operation of sixteen reverse flow loops; four of the loops are powered by an external source of energy, while the remaining loops are self-acting. Of the self-acting loops, vapor was used for heat transfer in seven of them and liquid was used in the remaining ones. Based on the available research results, a list of the advantages and disadvantages of both types of loops is presented.

  5. Differential response of peripheral arterial compliance-related indices to a vasoconstrictive stimulus.

    Science.gov (United States)

    Guerrisi, Maria; Vannucci, Italo; Toschi, Nicola

    2009-01-01

    Peripheral arterial elastic properties are greatly affected by cardiovascular as well as other pathologies, and their assessment can provide useful diagnostic indicators. The photoplethysmographic technique can provide finger blood volume and pressure waveforms non-invasively, which can then be processed statically or beat-to-beat to characterize parameters of the vessel wall mechanics. We employ an occlusion-deflation protocol in 48 healthy volunteers to study peripheral artery compliance-related indices over positive and negative transmural pressure values as well as under the influence of a valid vasoconstrictor (cigarette smoking). We calculate beat-to-beat indices (compliance index CI, distensibility index DI, three viscoelastic model parameters (compliance C, viscosity R and inertia L), pressure-volume loop areas A and damping factor DF as well as symmetrical (C(max)) and asymmetrical (C(A)(max)) static compliance estimates, and their distributions over transmural pressure. All distributions are bell-shaped and centred on negative transmural pressure values. Distribution heights were significantly lower in the smoking group (w.r.t. the non-smoking group) for C, CI, DI and significantly higher in R and DF. The estimated volume signal time lag was also significantly lower in the smoking group. Left and right distribution widths were significantly different in all parameters/groups but DI (both groups), C(A)(max), A (smoking group) and L (non-smoking group), and positions of maxima/minima were significantly altered in C(A)(max), R and DF. C, DF and CI are seen to be most sensitive under this protocol, while C(max) and C(A)(max) are seen to be insensitive. These quantities provide complementary, time- and transmural pressure-dependent information about arterial wall mechanics, and the choice of index should depend on the physiological conditions at hand as well as relevant time resolution and transmural pressure range.

  6. Differential response of peripheral arterial compliance-related indices to a vasoconstrictive stimulus

    International Nuclear Information System (INIS)

    Guerrisi, Maria; Vannucci, Italo; Toschi, Nicola

    2009-01-01

    Peripheral arterial elastic properties are greatly affected by cardiovascular as well as other pathologies, and their assessment can provide useful diagnostic indicators. The photoplethysmographic technique can provide finger blood volume and pressure waveforms non-invasively, which can then be processed statically or beat-to-beat to characterize parameters of the vessel wall mechanics. We employ an occlusion–deflation protocol in 48 healthy volunteers to study peripheral artery compliance-related indices over positive and negative transmural pressure values as well as under the influence of a valid vasoconstrictor (cigarette smoking). We calculate beat-to-beat indices (compliance index CI, distensibility index DI, three viscoelastic model parameters (compliance C, viscosity R and inertia L), pressure–volume loop areas A and damping factor DF as well as symmetrical (C max ) and asymmetrical (C A max ) static compliance estimates, and their distributions over transmural pressure. All distributions are bell-shaped and centred on negative transmural pressure values. Distribution heights were significantly lower in the smoking group (w.r.t. the non-smoking group) for C, CI, DI and significantly higher in R and DF. The estimated volume signal time lag was also significantly lower in the smoking group. Left and right distribution widths were significantly different in all parameters/groups but DI (both groups), C A max , A (smoking group) and L (non-smoking group), and positions of maxima/minima were significantly altered in C A max , R and DF. C, DF and CI are seen to be most sensitive under this protocol, while C max and C A max are seen to be insensitive. These quantities provide complementary, time- and transmural pressure-dependent information about arterial wall mechanics, and the choice of index should depend on the physiological conditions at hand as well as relevant time resolution and transmural pressure range

  7. Imaging of the peripheral retina

    Directory of Open Access Journals (Sweden)

    Marcus Kernt

    2013-01-01

    Full Text Available The technical progress of the recent years has revolutionized imaging in ophthalmology. Scanning laser ophthalmoscopy (SLO, digital angiography, optical coherence tomography (OCT, and detection of fundus autofluorescence (FAF have fundamentally changed our understanding of numerous retinal and choroidal diseases. Besides the tremendous advances in macular diagnostics, there is more and more evidence that central pathologies are often directly linked to changes in the peripheral retina. This review provides a brief overview on current posterior segment imaging techniques with a special focus on the peripheral retina.

  8. Comments on two-loop Kac-Moody algebras

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, L A; Gomes, J F; Zimerman, A H [Instituto de Fisica Teorica (IFT), Sao Paulo, SP (Brazil); Schwimmer, A [Istituto Nazionale di Fisica Nucleare, Trieste (Italy)

    1991-10-01

    It is shown that the two-loop Kac-Moody algebra is equivalent to a two variable loop algebra and a decouple {beta}-{gamma} system. Similarly WZNW and CSW models having as algebraic structure the Kac-Moody algebra are equivalent to an infinity to versions of the corresponding ordinary models and decoupled Abelian fields. (author). 15 refs.

  9. Self-oscillating loop based piezoelectric power converter

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention relates to a piezoelectric power converter comprising an input driver electrically coupled directly to an input or primary electrode of the piezoelectric transformer without any intervening series or parallel inductor. A feedback loop is operatively coupled between an output......- oscillation loop within a zero-voltage-switching (ZVS) operation range of the piezoelectric transformer....

  10. Covariant diagrams for one-loop matching

    International Nuclear Information System (INIS)

    Zhang, Zhengkang

    2016-10-01

    We present a diagrammatic formulation of recently-revived covariant functional approaches to one-loop matching from an ultraviolet (UV) theory to a low-energy effective field theory. Various terms following from a covariant derivative expansion (CDE) are represented by diagrams which, unlike conventional Feynman diagrams, involve gaugecovariant quantities and are thus dubbed ''covariant diagrams.'' The use of covariant diagrams helps organize and simplify one-loop matching calculations, which we illustrate with examples. Of particular interest is the derivation of UV model-independent universal results, which reduce matching calculations of specific UV models to applications of master formulas. We show how such derivation can be done in a more concise manner than the previous literature, and discuss how additional structures that are not directly captured by existing universal results, including mixed heavy-light loops, open covariant derivatives, and mixed statistics, can be easily accounted for.

  11. Defect networks and supersymmetric loop operators

    Energy Technology Data Exchange (ETDEWEB)

    Bullimore, Mathew [Perimeter Institute for Theoretical Physics, 31 Caroline Street North, Waterloo, ON N2L 2Y5 (Canada)

    2015-02-10

    We consider topological defect networks with junctions in A{sub N−1} Toda CFT and the connection to supersymmetric loop operators in N=2 theories of class S on a four-sphere. Correlation functions in the presence of topological defect networks are computed by exploiting the monodromy of conformal blocks, generalising the notion of a Verlinde operator. Concentrating on a class of topological defects in A{sub 2} Toda theory, we find that the Verlinde operators generate an algebra whose structure is determined by a set of generalised skein relations that encode the representation theory of a quantum group. In the second half of the paper, we explore the dictionary between topological defect networks and supersymmetric loop operators in the N=2{sup ∗} theory by comparing to exact localisation computations. In this context, the the generalised skein relations are related to the operator product expansion of loop operators.

  12. Covariant diagrams for one-loop matching

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Zhengkang [Michigan Center for Theoretical Physics (MCTP), University of Michigan,450 Church Street, Ann Arbor, MI 48109 (United States); Deutsches Elektronen-Synchrotron (DESY),Notkestraße 85, 22607 Hamburg (Germany)

    2017-05-30

    We present a diagrammatic formulation of recently-revived covariant functional approaches to one-loop matching from an ultraviolet (UV) theory to a low-energy effective field theory. Various terms following from a covariant derivative expansion (CDE) are represented by diagrams which, unlike conventional Feynman diagrams, involve gauge-covariant quantities and are thus dubbed “covariant diagrams.” The use of covariant diagrams helps organize and simplify one-loop matching calculations, which we illustrate with examples. Of particular interest is the derivation of UV model-independent universal results, which reduce matching calculations of specific UV models to applications of master formulas. We show how such derivation can be done in a more concise manner than the previous literature, and discuss how additional structures that are not directly captured by existing universal results, including mixed heavy-light loops, open covariant derivatives, and mixed statistics, can be easily accounted for.

  13. Covariant diagrams for one-loop matching

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Zhengkang [Michigan Univ., Ann Arbor, MI (United States). Michigan Center for Theoretical Physics; Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2016-10-15

    We present a diagrammatic formulation of recently-revived covariant functional approaches to one-loop matching from an ultraviolet (UV) theory to a low-energy effective field theory. Various terms following from a covariant derivative expansion (CDE) are represented by diagrams which, unlike conventional Feynman diagrams, involve gaugecovariant quantities and are thus dubbed ''covariant diagrams.'' The use of covariant diagrams helps organize and simplify one-loop matching calculations, which we illustrate with examples. Of particular interest is the derivation of UV model-independent universal results, which reduce matching calculations of specific UV models to applications of master formulas. We show how such derivation can be done in a more concise manner than the previous literature, and discuss how additional structures that are not directly captured by existing universal results, including mixed heavy-light loops, open covariant derivatives, and mixed statistics, can be easily accounted for.

  14. Covariant diagrams for one-loop matching

    International Nuclear Information System (INIS)

    Zhang, Zhengkang

    2017-01-01

    We present a diagrammatic formulation of recently-revived covariant functional approaches to one-loop matching from an ultraviolet (UV) theory to a low-energy effective field theory. Various terms following from a covariant derivative expansion (CDE) are represented by diagrams which, unlike conventional Feynman diagrams, involve gauge-covariant quantities and are thus dubbed “covariant diagrams.” The use of covariant diagrams helps organize and simplify one-loop matching calculations, which we illustrate with examples. Of particular interest is the derivation of UV model-independent universal results, which reduce matching calculations of specific UV models to applications of master formulas. We show how such derivation can be done in a more concise manner than the previous literature, and discuss how additional structures that are not directly captured by existing universal results, including mixed heavy-light loops, open covariant derivatives, and mixed statistics, can be easily accounted for.

  15. Development of a closed and open loop solar tracker technology

    Directory of Open Access Journals (Sweden)

    Aurélio Gouvêa Melo

    2017-05-01

    Full Text Available Solar energy is among the renewable energy sources that received greater addition in installed capacity. However, it accounts for a small fraction of the energy matrix of most countries. Electric energy generation by solar systems can be improved through tracking. This work aimed to develop and compare a closed and an open loop solar tracking system. The closed loop system was developed using Light Dependent Resistors. An algorithm was developed for the open loop tracker as a function of the geometric relation between the sun and the photovoltaic module. A simulation was run to compare this algorithm with a system using tracking at fixed time intervals, for clear sky conditions, with different tracking parameters and for five different latitudes. No significant difference was observed between the proposed open loop tracking algorithm and the fixed time interval algorithm for the tracking parameters evaluated. The open and closed loop solar tracking systems were compared experimentally in Rio das Ostras, Brazil (22.49 °S 41.92° W. An average gain of 28.5% was observed for the open loop tracking system over a latitude tilted system and 33.0% for the closed loop tracking system.

  16. On the One Loop Corrections to Inflation II

    DEFF Research Database (Denmark)

    Sloth, Martin Snoager

    2006-01-01

    In this paper we extend our previous treatment of the one-loop corrections to inflation. Previously we calculated the one-loop corrections to the background and the two-point correlation function of inflaton fluctuations in a specific model of chaotic inflation. We showed that the loop correction...... model of chaotic inflation with a quadratic inflationary potential. We discuss the physical interpretation of the effect in terms of the tensor-to-scalar consistency relation. Finally, we discuss the relation to the work of Weinberg on quantum contributions to cosmological correlators....

  17. A simple gastropexy for the loop-gastrostomy tube

    Directory of Open Access Journals (Sweden)

    Pang Ah-San

    2012-01-01

    Full Text Available The percutaneous endoscopic gastrostomy has been in clinical use for more than three decades. A recent innovation, the loop-gastrostomy, is more suitable for developing countries because the tube cannot be dislodged and is easy to change. Gastropexy and gastrostomy are separate but related moieties. We describe a novel technique to add a gastropexy to the loop-gastrostomy, using it successfully in a man with permanent dysphagia. It involved creating a secondary loop at the mid-portion of the LOOPPEG® 3G tube with absorbable ligatures.

  18. Peripheral Artery Disease

    Science.gov (United States)

    ... pressure High blood cholesterol Coronary heart disease Stroke Metabolic syndrome Screening and Prevention Taking action to control your risk factors can help prevent or delay peripheral artery disease (P.A.D.) and its complications. Know your family history of health problems related to P.A. ...

  19. Operation of a cascade air conditioning system with two-phase loop

    Science.gov (United States)

    Feng, Yinshan; Wang, Jinliang; Zhao, Futao; Verma, Parmesh; Radcliff, Thomas D.

    2018-05-29

    A method of operating a heat transfer system includes starting operation of a first heat transfer fluid vapor/compression circulation loop including a fluid pumping mechanism, a heat exchanger for rejecting thermal energy from a first heat transfer fluid, and a heat absorption side of an internal heat exchanger. A first conduit in a closed fluid circulation loop circulates the first heat transfer fluid therethrough. Operation of a second two-phase heat transfer fluid circulation loop is started after starting operation of the first heat transfer fluid circulation loop. The second heat transfer fluid circulation loop transfers heat to the first heat transfer fluid circulation loop through the internal heat exchanger and includes a heat rejection side of the internal heat exchanger, a liquid pump, and a heat exchanger evaporator. A second conduit in a closed fluid circulation loop circulates a second heat transfer fluid therethrough.

  20. Peripheral Osteoma of the Mandibular Notch: Report of a Case

    International Nuclear Information System (INIS)

    Iwai, Toshinori; Izumi, Toshiharu; Baba, Junichi; Maegawa, Jiro; Mitsudo, Kenji; Tohnai, Iwai

    2013-01-01

    Osteoma is a benign, slow-growing osteogenic tumor that sometimes arises from the craniomaxillofacial region, such as the sinus, temporal or jaw bones. Osteoma consists of compact or cancellous bone that may be peripheral, central or extraskeletal type. Peripheral osteoma arises from the periosteum and is commonly a unilateral, pedunculated mushroom-like mass. Peripheral osteoma of the mandible is relatively uncommon, and peripheral osteoma of the mandibular notch is extremely rare, although many cases arise from the mandibular body, angle, condyle, or coronoid process. We report here an unusual peripheral osteoma of the mandibular notch in a 78-year-old nonsyndromic female

  1. Mashup the OODA Loop

    National Research Council Canada - National Science Library

    Heier, Jeffrey E

    2008-01-01

    ...) processes via the Observe, Orient, Decide, and Act (OODA) Loop concept. As defined by Wikipedia, a mashup is a Website or application that combines the content from more than one source into an integrated presentation...

  2. Amino-acid composition after loop deletion drives domain swapping.

    Science.gov (United States)

    Nandwani, Neha; Surana, Parag; Udgaonkar, Jayant B; Das, Ranabir; Gosavi, Shachi

    2017-10-01

    Rational engineering of a protein to enable domain swapping requires an understanding of the sequence, structural and energetic factors that favor the domain-swapped oligomer over the monomer. While it is known that the deletion of loops between β-strands can promote domain swapping, the spliced sequence at the position of the loop deletion is thought to have a minimal role to play in such domain swapping. Here, two loop-deletion mutants of the non-domain-swapping protein monellin, frame-shifted by a single residue, were designed. Although the spliced sequence in the two mutants differed by only one residue at the site of the deletion, only one of them (YEIKG) promoted domain swapping. The mutant containing the spliced sequence YENKG was entirely monomeric. This new understanding that the domain swapping propensity after loop deletion may depend critically on the chemical composition of the shortened loop will facilitate the rational design of domain swapping. © 2017 The Protein Society.

  3. Logical inference techniques for loop parallelization

    KAUST Repository

    Oancea, Cosmin E.; Rauchwerger, Lawrence

    2012-01-01

    This paper presents a fully automatic approach to loop parallelization that integrates the use of static and run-time analysis and thus overcomes many known difficulties such as nonlinear and indirect array indexing and complex control flow. Our hybrid analysis framework validates the parallelization transformation by verifying the independence of the loop's memory references. To this end it represents array references using the USR (uniform set representation) language and expresses the independence condition as an equation, S = Ø, where S is a set expression representing array indexes. Using a language instead of an array-abstraction representation for S results in a smaller number of conservative approximations but exhibits a potentially-high runtime cost. To alleviate this cost we introduce a language translation F from the USR set-expression language to an equally rich language of predicates (F(S) ⇒ S = Ø). Loop parallelization is then validated using a novel logic inference algorithm that factorizes the obtained complex predicates (F(S)) into a sequence of sufficient-independence conditions that are evaluated first statically and, when needed, dynamically, in increasing order of their estimated complexities. We evaluate our automated solution on 26 benchmarks from PERFECTCLUB and SPEC suites and show that our approach is effective in parallelizing large, complex loops and obtains much better full program speedups than the Intel and IBM Fortran compilers. Copyright © 2012 ACM.

  4. One-loop Wilson loops and the particle-interface potential in AdS/dCFT

    Directory of Open Access Journals (Sweden)

    Marius de Leeuw

    2017-05-01

    Full Text Available We initiate the calculation of quantum corrections to Wilson loops in a class of four-dimensional defect conformal field theories with vacuum expectation values based on N=4 super Yang–Mills theory. Concretely, we consider an infinite straight Wilson line, obtaining explicit results for the one-loop correction to its expectation value in the large-N limit. This allows us to extract the particle-interface potential of the theory. In a further double-scaling limit, we compare our results to those of a previous calculation in the dual string-theory set-up consisting of a D5-D3 probe-brane system with flux, and we find perfect agreement.

  5. Peripheral Primitive Neuroectodermal Tumor of the Stomach: A Case Report

    International Nuclear Information System (INIS)

    Park, Woon Ju; Cho, June Sik; Shin, Kyung Sook; Jeong, Hyung Yong; Noh; Seung Moo; Song, Kyu Sang

    2010-01-01

    Peripheral primitive neuroectodermal tumors (peripheral PNETs) are very rare and highly aggressive soft tissue malignancies originating from the neural crest. To the best of our knowledge, only a few cases of peripheral PNETs of the stomach have been reported in the literature. We report a case of large peripheral primitive neuroectodermal tumor of the stomach with MDCT findings in a 22-year-old man presenting epigastric pain and vomiting

  6. A Triple-Loop Inductive Power Transmission System for Biomedical Applications.

    Science.gov (United States)

    Lee, Byunghun; Kiani, Mehdi; Ghovanloo, Maysam

    2016-02-01

    A triple-loop wireless power transmission (WPT) system equipped with closed-loop global power control, adaptive transmitter (Tx) resonance compensation (TRC), and automatic receiver (Rx) resonance tuning (ART) is presented. This system not only opposes coupling and load variations but also compensates for changes in the environment surrounding the inductive link to enhance power transfer efficiency (PTE) in applications such as implantable medical devices (IMDs). The Tx was built around a commercial off-the-shelf (COTS) radio-frequency identification (RFID) reader, operating at 13.56 MHz. A local Tx loop finds the optimal capacitance in parallel with the Tx coil by adjusting a varactor. A global power control loop maintains the received power at a desired level in the presence of changes in coupling distance, coil misalignments, and loading. Moreover, a local Rx loop is implemented inside a power management integrated circuit (PMIC) to avoid PTE degradation due to the Rx coil surrounding environment and process variations. The PMIC was fabricated in a 0.35- μm 4M2P standard CMOS process with 2.54 mm(2) active area. Measurement results show that the proposed triple-loop system improves the overall PTE by up to 10.5% and 4.7% compared to a similar open- and single closed-loop system, respectively, at nominal coil distance of 2 cm. The added TRC and ART loops contribute 2.3% and 1.4% to the overall PTE of 13.5%, respectively. This is the first WPT system to include three loops to dynamically compensate for environment and circuit variations and improve the overall power efficiency all the way from the driver output in Tx to the load in Rx.

  7. Peripheral T-Cell Lymphoma

    Science.gov (United States)

    ... Non-Hodgkin Lymphoma Peripheral T-Cell Lymphoma Primary Central Nervous System Lymphoma T-Cell Lymphoma Transformed Mycosis Fungoides Waldenstrom Macroglobulinemia Young Adult Lymphoma Overview Treatment Options Relapsed/Refractory Long-term ...

  8. Quantum Kinematics of Bosonic Vortex Loops

    International Nuclear Information System (INIS)

    Goldin, G.A.; Owczarek, R.; Sharp, D.H.

    1999-01-01

    Poisson structure for vortex filaments (loops and arcs) in 2D ideal incompressible fluid is analyzed in detail. Canonical coordinates and momenta on coadjoint orbits of the area-preserving diffeomorphism group, associated with such vortices, are found. The quantum space of states in the simplest case of ''bosonic'' vortex loops is built within a geometric quantization approach to the description of a quantum fluid. Fock-like structure and non-local creation and annihilation operators of quantum vortex filaments are introduced

  9. Peripheral facial palsy in children.

    Science.gov (United States)

    Yılmaz, Unsal; Cubukçu, Duygu; Yılmaz, Tuba Sevim; Akıncı, Gülçin; Ozcan, Muazzez; Güzel, Orkide

    2014-11-01

    The aim of this study is to evaluate the types and clinical characteristics of peripheral facial palsy in children. The hospital charts of children diagnosed with peripheral facial palsy were reviewed retrospectively. A total of 81 children (42 female and 39 male) with a mean age of 9.2 ± 4.3 years were included in the study. Causes of facial palsy were 65 (80.2%) idiopathic (Bell palsy) facial palsy, 9 (11.1%) otitis media/mastoiditis, and tumor, trauma, congenital facial palsy, chickenpox, Melkersson-Rosenthal syndrome, enlarged lymph nodes, and familial Mediterranean fever (each 1; 1.2%). Five (6.1%) patients had recurrent attacks. In patients with Bell palsy, female/male and right/left ratios were 36/29 and 35/30, respectively. Of them, 31 (47.7%) had a history of preceding infection. The overall rate of complete recovery was 98.4%. A wide variety of disorders can present with peripheral facial palsy in children. Therefore, careful investigation and differential diagnosis is essential. © The Author(s) 2013.

  10. Integrable systems and loop coproducts

    International Nuclear Information System (INIS)

    Musso, Fabio

    2010-01-01

    We present a generalization of a framework for the construction of classical integrable systems that we call loop coproduct formulation (Musso 2010 J. Phys. A: Math. Theor. 43 434026). In this paper, the loop coproduct formulation includes systems of Gelfand-Tsetlin type, the linear r-matrix formulation, the Sklyanin algebras, the reflection algebras, the coalgebra symmetry approach and some of its generalizations as particular cases, showing that all these apparently different approaches have a common algebraic origin. On the other hand, all these subcases do not exhaust the domain of applicability of this new technique, so that new possible directions of investigation do naturally emerge in this framework.

  11. Peripheral doses from pediatric IMRT

    International Nuclear Information System (INIS)

    Klein, Eric E.; Maserang, Beth; Wood, Roy; Mansur, David

    2006-01-01

    Peripheral dose (PD) data exist for conventional fields (≥10 cm) and intensity-modulated radiotherapy (IMRT) delivery to standard adult-sized phantoms. Pediatric peripheral dose reports are limited to conventional therapy and are model based. Our goal was to ascertain whether data acquired from full phantom studies and/or pediatric models, with IMRT treatment times, could predict Organ at Risk (OAR) dose for pediatric IMRT. As monitor units (MUs) are greater for IMRT, it is expected IMRT PD will be higher; potentially compounded by decreased patient size (absorption). Baseline slab phantom peripheral dose measurements were conducted for very small field sizes (from 2 to 10 cm). Data were collected at distances ranging from 5 to 72 cm away from the field edges. Collimation was either with the collimating jaws or the multileaf collimator (MLC) oriented either perpendicular or along the peripheral dose measurement plane. For the clinical tests, five patients with intracranial or base of skull lesions were chosen. IMRT and conventional three-dimensional (3D) plans for the same patient/target/dose (180 cGy), were optimized without limitation to the number of fields or wedge use. Six MV, 120-leaf MLC Varian axial beams were used. A phantom mimicking a 3-year-old was configured per Center for Disease Control data. Micro (0.125 cc) and cylindrical (0.6 cc) ionization chambers were appropriated for the thyroid, breast, ovaries, and testes. The PD was recorded by electrometers set to the 10 -10 scale. Each system set was uniquely calibrated. For the slab phantom studies, close peripheral points were found to have a higher dose for low energy and larger field size and when MLC was not deployed. For points more distant from the field edge, the PD was higher for high-energy beams. MLC orientation was found to be inconsequential for the small fields tested. The thyroid dose was lower for IMRT delivery than that predicted for conventional (ratio of IMRT/cnventional ranged from

  12. High Temperature Operational Experiences of Helium Experimental Loop

    International Nuclear Information System (INIS)

    Kim, Chan Soo; Hong, Sung-Deok; Kim, Eung-Seon; Kim, Min Hwan

    2015-01-01

    The development of high temperature components of VHTR is very important because of its higher operation temperature than that of a common light water reactor and high pressure industrial process. The development of high temperature components requires the large helium loop. Many countries have high temperature helium loops or a plan for its construction. Table 1 shows various international state-of-the-art of high temperature and high pressure gas loops. HELP performance test results show that there is no problem in operation of HELP at the very high temperature experimental condition. These experimental results also provide the basic information for very high temperature operation with bench-scale intermediate heat exchanger prototype in HELP. In the future, various heat exchanger tests will give us the experimental data for GAMMA+ validation about transient T/H behavior of the IHX prototype and the optimization of the working fluid in the intermediate loop

  13. Nonlinear model predictive control for chemical looping process

    Science.gov (United States)

    Joshi, Abhinaya; Lei, Hao; Lou, Xinsheng

    2017-08-22

    A control system for optimizing a chemical looping ("CL") plant includes a reduced order mathematical model ("ROM") that is designed by eliminating mathematical terms that have minimal effect on the outcome. A non-linear optimizer provides various inputs to the ROM and monitors the outputs to determine the optimum inputs that are then provided to the CL plant. An estimator estimates the values of various internal state variables of the CL plant. The system has one structure adapted to control a CL plant that only provides pressure measurements in the CL loops A and B, a second structure adapted to a CL plant that provides pressure measurements and solid levels in both loops A, and B, and a third structure adapted to control a CL plant that provides full information on internal state variables. A final structure provides a neural network NMPC controller to control operation of loops A and B.

  14. An efficiency booster for energy conversion in natural circulation loops

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Dongqing, E-mail: wangdongqing@stu.xjtu.edu.cn [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an, Shaanxi 710049 (China); Beijing Computational Science Research Center, Beijing 100084 (China); Jiang, Jin, E-mail: jjiang@eng.uwo.ca [Department of Electrical and Computer Engineering, The University of Western Ontario, London, Ontario N6A 5B9 (Canada); Beijing Computational Science Research Center, Beijing 100084 (China)

    2016-08-01

    Highlights: • Low driving power conversion efficiency of natural circulation loops is proved. • The low conversion efficiency leads to low heat transfer capacity of such loops. • An efficiency booster is designed with turbine to increase the efficiency. • Performance of the proposed booster has been numerically simulated. • The booster drastically enhances heat transfer capacity of such loops. - Abstract: In this paper, the capacity of a natural circulation loop for transferring heat from a heat source to a heat sink has been analyzed. It is concluded that the capacity of the natural circulation loop depends on the conversion efficiency of the thermal energy from the heat source to the driving force for the circulation of the flow. The low conversion efficiency leading to weak driving force in such loops has been demonstrated analytically and validated through simulation results. This issue has resulted in a low heat transfer capacity in the circulation loop. To increase the heat transfer capacity, one has to improve this efficiency. To meet such a need, a novel efficiency booster has been developed in this paper. The booster essentially increases the flow driving force and hence significantly improves the overall heat transfer capacity. Design and analysis of this booster have been performed in detail. The performance has been examined through extensive computer simulations. It is concluded that the booster can indeed drastically improve the heat transfer capacity of the natural circulation loop.

  15. An efficiency booster for energy conversion in natural circulation loops

    International Nuclear Information System (INIS)

    Wang, Dongqing; Jiang, Jin

    2016-01-01

    Highlights: • Low driving power conversion efficiency of natural circulation loops is proved. • The low conversion efficiency leads to low heat transfer capacity of such loops. • An efficiency booster is designed with turbine to increase the efficiency. • Performance of the proposed booster has been numerically simulated. • The booster drastically enhances heat transfer capacity of such loops. - Abstract: In this paper, the capacity of a natural circulation loop for transferring heat from a heat source to a heat sink has been analyzed. It is concluded that the capacity of the natural circulation loop depends on the conversion efficiency of the thermal energy from the heat source to the driving force for the circulation of the flow. The low conversion efficiency leading to weak driving force in such loops has been demonstrated analytically and validated through simulation results. This issue has resulted in a low heat transfer capacity in the circulation loop. To increase the heat transfer capacity, one has to improve this efficiency. To meet such a need, a novel efficiency booster has been developed in this paper. The booster essentially increases the flow driving force and hence significantly improves the overall heat transfer capacity. Design and analysis of this booster have been performed in detail. The performance has been examined through extensive computer simulations. It is concluded that the booster can indeed drastically improve the heat transfer capacity of the natural circulation loop.

  16. Virtual grasping: closed-loop force control using electrotactile feedback.

    Science.gov (United States)

    Jorgovanovic, Nikola; Dosen, Strahinja; Djozic, Damir J; Krajoski, Goran; Farina, Dario

    2014-01-01

    Closing the control loop by providing somatosensory feedback to the user of a prosthesis is a well-known, long standing challenge in the field of prosthetics. Various approaches have been investigated for feedback restoration, ranging from direct neural stimulation to noninvasive sensory substitution methods. Although there are many studies presenting closed-loop systems, only a few of them objectively evaluated the closed-loop performance, mostly using vibrotactile stimulation. Importantly, the conclusions about the utility of the feedback were partly contradictory. The goal of the current study was to systematically investigate the capability of human subjects to control grasping force in closed loop using electrotactile feedback. We have developed a realistic experimental setup for virtual grasping, which operated in real time, included a set of real life objects, as well as a graphical and dynamical model of the prosthesis. We have used the setup to test 10 healthy, able bodied subjects to investigate the role of training, feedback and feedforward control, robustness of the closed loop, and the ability of the human subjects to generalize the control to previously "unseen" objects. Overall, the outcomes of this study are very optimistic with regard to the benefits of feedback and reveal various, practically relevant, aspects of closed-loop control.

  17. Virtual Grasping: Closed-Loop Force Control Using Electrotactile Feedback

    Directory of Open Access Journals (Sweden)

    Nikola Jorgovanovic

    2014-01-01

    Full Text Available Closing the control loop by providing somatosensory feedback to the user of a prosthesis is a well-known, long standing challenge in the field of prosthetics. Various approaches have been investigated for feedback restoration, ranging from direct neural stimulation to noninvasive sensory substitution methods. Although there are many studies presenting closed-loop systems, only a few of them objectively evaluated the closed-loop performance, mostly using vibrotactile stimulation. Importantly, the conclusions about the utility of the feedback were partly contradictory. The goal of the current study was to systematically investigate the capability of human subjects to control grasping force in closed loop using electrotactile feedback. We have developed a realistic experimental setup for virtual grasping, which operated in real time, included a set of real life objects, as well as a graphical and dynamical model of the prosthesis. We have used the setup to test 10 healthy, able bodied subjects to investigate the role of training, feedback and feedforward control, robustness of the closed loop, and the ability of the human subjects to generalize the control to previously “unseen” objects. Overall, the outcomes of this study are very optimistic with regard to the benefits of feedback and reveal various, practically relevant, aspects of closed-loop control.

  18. Peripheral Protein Unfolding Drives Membrane Bending.

    Science.gov (United States)

    Siaw, Hew Ming Helen; Raghunath, Gokul; Dyer, R Brian

    2018-06-20

    Dynamic modulation of lipid membrane curvature can be achieved by a number of peripheral protein binding mechanisms such as hy-drophobic insertion of amphipathic helices and membrane scaffolding. Recently, an alternative mechanism was proposed in which crowding of peripherally bound proteins induces membrane curvature through steric pressure generated by lateral collisions. This effect was enhanced using intrinsically disordered proteins that possess high hydrodynamic radii, prompting us to explore whether membrane bending can be triggered by the folding-unfolding transition of surface-bound proteins. We utilized histidine-tagged human serum albumin bound to Ni-NTA-DGS containing liposomes as our model system to test this hypothesis. We found that reduction of the disulfide bonds in the protein resulted in unfolding of HSA, which subsequently led to membrane tubule formation. The frequency of tubule formation was found to be significantly higher when the proteins were unfolded while being localized to a phase-separated domain as opposed to randomly distributed in fluid phase liposomes, indicating that the steric pressure generated from protein unfolding is directly responsible for membrane deformation. Our results are critical for the design of peripheral membrane protein-immobilization strategies and open new avenues for exploring mechanisms of membrane bending driven by conformational changes of peripheral membrane proteins.

  19. 21 CFR 882.5870 - Implanted peripheral nerve stimulator for pain relief.

    Science.gov (United States)

    2010-04-01

    ....5870 Implanted peripheral nerve stimulator for pain relief. (a) Identification. An implanted peripheral nerve stimulator for pain relief is a device that is used to stimulate electrically a peripheral nerve... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Implanted peripheral nerve stimulator for pain...

  20. Peripheral dose outside applicators in electron beams

    International Nuclear Information System (INIS)

    Chow, James C L; Grigorov, Grigor N

    2006-01-01

    The peripheral dose outside the applicators in electron beams was studied using a Varian 21 EX linear accelerator. To measure the peripheral dose profiles and point doses for the applicator, a solid water phantom was used with calibrated Kodak TL films. Peak dose spot was observed in the 4 MeV beam outside the applicator. The peripheral dose peak was very small in the 6 MeV beam and was ignorable at higher energies. Using the 10 x 10 cm 2 cutout and applicator, the dose peak for the 4 MeV beam was about 12 cm away from the field central beam axis (CAX) and the peripheral dose profiles did not change with depths measured at 0.2, 0.5 and 1 cm. The peripheral doses and profiles were further measured by varying the angle of obliquity, cutout and applicator size for the 4 MeV beam. The local peak dose was increased with about 3% per degree angle of obliquity, and was about 1% of the prescribed dose (angle of obliquity equals zero) at 1 cm depth in the phantom using the 10 x 10 cm 2 cutout and applicator. The peak dose position was also shifted 7 mm towards the CAX when the angle of obliquity was increased from 0 to 15 deg. (note)

  1. Two loop integrals and QCD scattering

    International Nuclear Information System (INIS)

    Anastasiou, C.

    2001-04-01

    We present the techniques for the calculation of one- and two-loop integrals contributing to the virtual corrections to 2→2 scattering of massless particles. First, tensor integrals are related to scalar integrals with extra powers of propagators and higher dimension using the Schwinger representation. Integration By Parts and Lorentz Invariance recurrence relations reduce the number of independent scalar integrals to a set of master integrals for which their expansion in ε = 2 - D/2 is calculated using a combination of Feynman parameters, the Negative Dimension Integration Method, the Differential Equations Method, and Mellin-Barnes integral representations. The two-loop matrix-elements for light-quark scattering are calculated in Conventional Dimensional Regularisation by direct evaluation of the Feynman diagrams. The ultraviolet divergences are removed by renormalising with the MS-bar scheme. Finally, the infrared singular behavior is shown to be in agreement with the one anticipated by the application of Catani's formalism for the infrared divergences of generic QCD two-loop amplitudes. (author)

  2. Experimental loop for SH2 (LECS)

    International Nuclear Information System (INIS)

    Strehar, N.R.; Bruzzoni, Pablo; Moras, J.J.; Cogozzo, E.O.

    1981-01-01

    An experimental loop is described for circulation of SH 2 that operates at 2 x 10 6 Pascal and 33 deg C. It was designed and constructed with the purpose of experimentally studying the hydraulic instability phenomenon that can be detected in cold isotopic exchange columns in the Girdler-Sulfide (GS) process of heavy water production. The main features of the different components of the loop are described, as well as the materials, the measurement and control instruments and the auxiliary equipment used, and finally the measuring methods to qualify and quantify the formation of froth. Furthermore, the loop's transportable metallic container is described, which allows to transport and connect it to CNEA's experimental heavy water plant or to any other heavy water plants using the GS method. Some tests made with inert gases that intended to verify the equipment's performance and to select the most adequate sieve trays for its operation are discussed. (M.E.L.) [es

  3. Loop Entropy Assists Tertiary Order: Loopy Stabilization of Stacking Motifs

    Directory of Open Access Journals (Sweden)

    Daniel P. Aalberts

    2011-11-01

    Full Text Available The free energy of an RNA fold is a combination of favorable base pairing and stacking interactions competing with entropic costs of forming loops. Here we show how loop entropy, surprisingly, can promote tertiary order. A general formula for the free energy of forming multibranch and other RNA loops is derived with a polymer-physics based theory. We also derive a formula for the free energy of coaxial stacking in the context of a loop. Simulations support the analytic formulas. The effects of stacking of unpaired bases are also studied with simulations.

  4. Conceptual Design for a High-Temperature Gas Loop Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    James B. Kesseli

    2006-08-01

    This report documents an early-stage conceptual design for a high-temperature gas test loop. The objectives accomplished by the study include, (1) investigation of existing gas test loops to determine ther capabilities and how the proposed system might best complement them, (2) development of a preliminary test plan to help identify the performance characteristics required of the test unit, (3) development of test loop requirements, (4) development of a conceptual design including process flow sheet, mechanical layout, and equipment specifications and costs, and (5) development of a preliminary test loop safety plan.

  5. Intraoperative digital angiography: Peripheral vascular applications

    International Nuclear Information System (INIS)

    Bell, K.; Reifsteck, J.E.; Binet, E.F.; Fleisher, H.J.

    1986-01-01

    Intraoperative digital angiography is the procedure of choice for the peripheral vascular surgeon who wishes to evaluate his results before terminating anesthesia. Two operating suites at the John L. McClellan Memorial Veterans Hospital are equipped with permanent ceiling-mounted Philips C-arm fluoroscopes and share an ADAC 4100 digital angiographic system. In the last 18 months, 40 peripheral vascular intraoperative digital angiographic procedures have been performed, in all but two cases using direct arterial puncture. In 65% of cases, the intraoperative study showed no significant abnormality. In 12.5%, minor abnormalities not requiring reoperation were seen. In 22.5% of cases, the intraoperative digital angiogram revealed a significant abnormality requiring immediate operative revision. None of the patients who underwent reoperation experienced postoperative sequelae. Intraoperative digital angiography is useful in identifying complications of peripheral vascular operations

  6. Atomistic simulations of the formation of -component dislocation loops in α-zirconium

    Energy Technology Data Exchange (ETDEWEB)

    Dai, Cong, E-mail: dai.cong@queensu.ca; Balogh, Levente; Yao, Zhongwen; Daymond, Mark R., E-mail: mark.daymond@queensu.ca

    2016-09-15

    The formation of -component dislocation loops in α-Zr is believed to be responsible for the breakaway irradiation growth experimentally observed under high irradiation fluences. However, while -loop growth is well described by existing models, the atomic mechanisms responsible for the nucleation of -component dislocation loops are still not clear. In the present work, both interstitial and vacancy -type dislocation loops are initially equilibrated at different temperatures. Cascades simulations in the vicinity of the -type loops are then performed by selecting an atom as the primary knock-on atoms (PKAs) with different kinetic energies, using molecular dynamics simulations. No -component dislocation loop was formed in cascades simulations with a 10 keV PKA, but -component interstitial loops were observed after the interaction between discontinuous 50 keV PKAs and pre-existing -type interstitial loops. The comparisons of cascades simulations in volumes having pre-existing -type interstitial and vacancy loops suggest that the reaction between the PKAs and -type interstitial loops is responsible for the formation of -component interstitial loops.

  7. Peripheral nerve conduits: technology update

    Directory of Open Access Journals (Sweden)

    Arslantunali D

    2014-12-01

    Full Text Available D Arslantunali,1–3,* T Dursun,1,2,* D Yucel,1,4,5 N Hasirci,1,2,6 V Hasirci,1,2,7 1BIOMATEN, Center of Excellence in Biomaterials and Tissue Engineering, Middle East Technical University (METU, Ankara, Turkey; 2Department of Biotechnology, METU, Ankara, Turkey; 3Department of Bioengineering, Gumushane University, Gumushane, Turkey; 4Faculty of Engineering, Department of Medical Engineering, Acibadem University, Istanbul, Turkey; 5School of Medicine, Department of Histology and Embryology, Acibadem University, Istanbul, Turkey; 6Department of Chemistry, Faculty of Arts and Sciences, METU, Ankara, Turkey; 7Department of Biological Sciences, Faculty of Arts and Sciences, METU, Ankara, Turkey *These authors have contributed equally to this work Abstract: Peripheral nerve injury is a worldwide clinical problem which could lead to loss of neuronal communication along sensory and motor nerves between the central nervous system (CNS and the peripheral organs and impairs the quality of life of a patient. The primary requirement for the treatment of complete lesions is a tension-free, end-to-end repair. When end-to-end repair is not possible, peripheral nerve grafts or nerve conduits are used. The limited availability of autografts, and drawbacks of the allografts and xenografts like immunological reactions, forced the researchers to investigate and develop alternative approaches, mainly nerve conduits. In this review, recent information on the various types of conduit materials (made of biological and synthetic polymers and designs (tubular, fibrous, and matrix type are being presented. Keywords: peripheral nerve injury, natural biomaterials, synthetic biomaterials

  8. Numerical implementation of the loop-tree duality method

    Energy Technology Data Exchange (ETDEWEB)

    Buchta, Sebastian; Rodrigo, German [Universitat de Valencia-Consejo Superior de Investigaciones Cientificas, Parc Cientific, Instituto de Fisica Corpuscular, Valencia (Spain); Chachamis, Grigorios [Universidad Autonoma de Madrid, Instituto de Fisica Teorica UAM/CSIC, Madrid (Spain); Draggiotis, Petros [Institute of Nuclear and Particle Physics, NCSR ' ' Demokritos' ' , Agia Paraskevi (Greece)

    2017-05-15

    We present a first numerical implementation of the loop-tree duality (LTD) method for the direct numerical computation of multi-leg one-loop Feynman integrals. We discuss in detail the singular structure of the dual integrands and define a suitable contour deformation in the loop three-momentum space to carry out the numerical integration. Then we apply the LTD method to the computation of ultraviolet and infrared finite integrals, and we present explicit results for scalar and tensor integrals with up to eight external legs (octagons). The LTD method features an excellent performance independently of the number of external legs. (orig.)

  9. Electron cyclotron wave acceleration outside a flaring loop

    Science.gov (United States)

    Sprangle, P.; Vlahos, L.

    1983-01-01

    A model for the secondary acceleration of electrons outside a flaring loop is proposed. The results suggest that the narrow bandwidth radiation emitted by the unstable electron distribution inside a flaring loop can become the driver for secondary electron acceleration outside the loop. It is shown that a system of electrons gyrating about and streaming along an adiabatically spatially varying, static magnetic field can be efficiently accelerated to high energies by an electromagnetic wave propagating along and polarized transverse to the static magnetic field. The predictions from our model appear to be in general agreement with existing observations.

  10. Electron cyclotron wave acceleration outside a flaring loop

    International Nuclear Information System (INIS)

    Sprangle, P.; Vlahos, L.

    1983-01-01

    We propose a model for the secondary acceleration of electrons outside a flaring loop. Our results suggest that the narrow bandwidth radiation emitted by the unstable electron distribution inside a flaring loop can become the driver for secondary electron acceleration outside the loop. We show that a system of electrons gyrating about and streaming along an adiabatically spatially varying, static magnetic field can be efficiently accelerated to high energies by an electromagnetic wave propagating along and polarized transverse to the static magnetic field. The predictions from our model appear to be in general agreement with existing observations

  11. A Quasi-Type-1 Phase-Locked Loop Structure

    DEFF Research Database (Denmark)

    Golestan, Saeed; Fernandez, Francisco Daniel Freijedo; Vidal, Ana

    2014-01-01

    The grid voltage phase and frequency are crucial information in control of most grid connected power electronic based equipment. Most often, a phase-locked loop (PLL) is employed for this purpose. A PLL is a closed-loop feedback control system that the phase of its output signal is related...... to the phase of its input signal. Arguably, the simplest PLL is a type-1 PLL. The type-1 PLLs are characterized by having only one integrator in their control loop and therefore having a high stability margin. However, they suffer from a serious drawback: they cannot achieve zero average steady-state phase...

  12. The diamond rule for multi-loop Feynman diagrams

    International Nuclear Information System (INIS)

    Ruijl, B.; Ueda, T.; Vermaseren, J.A.M.

    2015-01-01

    An important aspect of improving perturbative predictions in high energy physics is efficiently reducing dimensionally regularised Feynman integrals through integration by parts (IBP) relations. The well-known triangle rule has been used to achieve simple reduction schemes. In this work we introduce an extensible, multi-loop version of the triangle rule, which we refer to as the diamond rule. Such a structure appears frequently in higher-loop calculations. We derive an explicit solution for the recursion, which prevents spurious poles in intermediate steps of the computations. Applications for massless propagator type diagrams at three, four, and five loops are discussed

  13. One-loop partition functions of 3D gravity

    International Nuclear Information System (INIS)

    Giombi, Simone; Yin Xi; Maloney, Alexander

    2008-01-01

    We consider the one-loop partition function of free quantum field theory in locally Anti-de Sitter space-times. In three dimensions, the one loop determinants for scalar, gauge and graviton excitations are computed explicitly using heat kernel techniques. We obtain precisely the result anticipated by Brown and Henneaux: the partition function includes a sum over 'boundary excitations' of AdS 3 , which are the Virasoro descendants of empty Anti-de Sitter space. This result also allows us to compute the one-loop corrections to the Euclidean action of the BTZ black hole as well its higher genus generalizations.

  14. Management of peripheral facial nerve palsy

    OpenAIRE

    Finsterer, Josef

    2008-01-01

    Peripheral facial nerve palsy (FNP) may (secondary FNP) or may not have a detectable cause (Bell?s palsy). Three quarters of peripheral FNP are primary and one quarter secondary. The most prevalent causes of secondary FNP are systemic viral infections, trauma, surgery, diabetes, local infections, tumor, immunological disorders, or drugs. The diagnosis of FNP relies upon the presence of typical symptoms and signs, blood chemical investigations, cerebro-spinal-fluid-investigations, X-ray of the...

  15. A Role for the Cytoskeleton in Heart Looping

    Directory of Open Access Journals (Sweden)

    Kersti K. Linask

    2007-01-01

    Full Text Available Over the past 10 years, key genes involved in specification of left-right laterality pathways in the embryo have been defined. The read-out for misexpression of laterality genes is usually the direction of heart looping. The question of how dextral looping direction occurred mechanistically and how the heart tube bends remains unknown. It is becoming clear from our experiments and those of others that left-right differences in cell proliferation in the second heart field (anterior heart field drives the dextral direction. Evidence is accumulating that the cytoskeleton is at the center of laterality, and the bending and rotational forces associated with heart looping. If laterality pathways are modulated upstream, the cytoskeleton, including nonmuscle myosin II (NMHC-II, is altered downstream within the cardiomyocytes, leading to looping abnormalities. The cytoskeleton is associated with important mechanosensing and signaling pathways in cell biology and development. The initiation of blood flow during the looping period and the inherent stresses associated with increasing volumes of blood flowing into the heart may help to potentiate the process. In recent years, the steps involved in this central and complex process of heart development that is the basis of numerous congenital heart defects are being unraveled.

  16. Closed Loop Experiment Manager (CLEM—An Open and Inexpensive Solution for Multichannel Electrophysiological Recordings and Closed Loop Experiments

    Directory of Open Access Journals (Sweden)

    Hananel Hazan

    2017-10-01

    Full Text Available There is growing need for multichannel electrophysiological systems that record from and interact with neuronal systems in near real-time. Such systems are needed, for example, for closed loop, multichannel electrophysiological/optogenetic experimentation in vivo and in a variety of other neuronal preparations, or for developing and testing neuro-prosthetic devices, to name a few. Furthermore, there is a need for such systems to be inexpensive, reliable, user friendly, easy to set-up, open and expandable, and possess long life cycles in face of rapidly changing computing environments. Finally, they should provide powerful, yet reasonably easy to implement facilities for developing closed-loop protocols for interacting with neuronal systems. Here, we survey commercial and open source systems that address these needs to varying degrees. We then present our own solution, which we refer to as Closed Loop Experiments Manager (CLEM. CLEM is an open source, soft real-time, Microsoft Windows desktop application that is based on a single generic personal computer (PC and an inexpensive, general-purpose data acquisition board. CLEM provides a fully functional, user-friendly graphical interface, possesses facilities for recording, presenting and logging electrophysiological data from up to 64 analog channels, and facilities for controlling external devices, such as stimulators, through digital and analog interfaces. Importantly, it includes facilities for running closed-loop protocols written in any programming language that can generate dynamic link libraries (DLLs. We describe the application, its architecture and facilities. We then demonstrate, using networks of cortical neurons growing on multielectrode arrays (MEA that despite its reliance on generic hardware, its performance is appropriate for flexible, closed-loop experimentation at the neuronal network level.

  17. Normal and sonographic anatomy of selected peripheral nerves. Part II: Peripheral nerves of the upper limb

    Directory of Open Access Journals (Sweden)

    Berta Kowalska

    2012-06-01

    Full Text Available The ultrasonographic examination is frequently used for imaging peripheral nerves. It serves to supplement the physical examination, electromyography, and magnetic resonance imaging. As in the case of other USG imaging studies, the examination of peripheral nerves is non-invasive, well-tolerated by patients, and relatively inexpensive. Part I of this article series described in detail the characteristic USG picture of peripheral nerves and the proper examination technique, following the example of the median nerve. This nerve is among the most often examined peripheral nerves of the upper limb. This part presents describes the normal anatomy and ultrasound picture of the remaining large nerve branches in the upper extremity and neck – the spinal accessory nerve, the brachial plexus, the suprascapular, axillary, musculocutaneous, radial and ulnar nerves. Their normal anatomy and ultrasonographic appearance have been described, including the division into individual branches. For each of them, specific reference points have been presented, to facilitate the location of the set trunk and its further monitoring. Sites for the application of the ultrasonographic probe at each reference point have been indicated. In the case of the ulnar nerve, the dynamic component of the examination was emphasized. The text is illustrated with images of probe positioning, diagrams of the normal course of the nerves as well as a series of ultrasonographic pictures of normal nerves of the upper limb. This article aims to serve as a guide in the ultrasound examination of the peripheral nerves of the upper extremity. It should be remembered that a thorough knowledge of the area’s topographic anatomy is required for this type of examination.

  18. Peripheral Atherectomy: Applications and Techniques.

    Science.gov (United States)

    Mittleider, Derek; Russell, Erich

    2016-06-01

    Peripheral atherectomy is a class of procedures that is rapidly increasing in volume. Multiple classes of devices exist, and newer variants are added to the market annually. The devices see wide application for de novo lesions, in-stent restenosis, and adjunctive therapy for drug-coated balloons. The body of evidence supporting atherectomy is less robust than for many other peripheral therapies. The frequency and severity of complications from atherectomy can be significant compared with angioplasty and stenting, and familiarity with preventative and bailout techniques is essential for the interventionalist. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Vapor Compressor Driven Hybrid Two-Phase Loop, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase I project will demonstrate a vapor compressor driven hybrid two-phase loop technology. The hybrid two-phase loop...

  20. Cytokine loops driving senescence

    Czech Academy of Sciences Publication Activity Database

    Bartek, Jiří; Hodný, Zdeněk; Lukáš, Jan

    2008-01-01

    Roč. 10, č. 8 (2008), s. 887-889 ISSN 1465-7392 Institutional research plan: CEZ:AV0Z50520514 Keywords : cellular senescence * cytokines * autocrine feedback loop Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 17.774, year: 2008

  1. Imaging of a glioma using peripheral benzodiazepine receptor ligands

    Energy Technology Data Exchange (ETDEWEB)

    Starosta-Rubinstein, S.; Ciliax, B.J.; Penney, J.B.; McKeever, P.; Young, A.B.

    1987-02-01

    Two types of benzodiazepine receptors have been demonstrated in mammalian tissues, one which is localized on neuronal elements in brain and the other, on glial cells and in peripheral tissues such as kidney. In vivo administration of /sup 3/H-labeled PK 11195 (1-(2-chlorophenyl-N-methyl-N-(1-methylpropyl)-3-isoquinoline carboxamide) or (/sup 3/H)flunitrazepam with 5 mg of clonazepam per kg to rats with intracranial C6 gliomas resulted in high levels of tritiated-drug binding to the tumor as shown by quantitative autoradiography. Pharmacological studies indicated that the bound drugs labeled the peripheral benzodiazepine binding site. Binding to the peripheral benzodiazepine site was confirmed primarily to malignant cells with little binding to adjacent normal brain tissue or to necrotic tissue. Tumor cell binding was completely inhibited by preadministration of the peripheral benzodiazepine blocking agent PK 11195 at 5 mg/kg. The centrally selective benzodiazepine ligand clonazepam had no effect on PK 11195 binding to the tumor cells. When binding to other tumor cell lines grown in nude mice and nude athymic rats was evaluated, little or no peripheral benzodiazepine binding was detected on human pheochromocytoma (RN1) and neuroblastoma (SK-N-MC, SK-N-SH) tumor cells, respectively. However, high densities of peripheral benzodiazepine binding sites were observed on tumors derived from a human glioma cell line (ATCC HTB 14, U-87 MG). The presence of high concentrations of specific peripheral benzodiazepine receptors on glial tumors suggests that human primary central nervous system tumors could be imaged and diagnosed using peripheral benzodiazepine ligands labeled with positron- or gamma-emitting isotopes.

  2. Growth and instability of charged dislocation loops under irradiation in ceramic materials

    CERN Document Server

    Ryazanov, A I; Kinoshita, C; Klaptsov, A V

    2002-01-01

    We have investigated the physical mechanisms of the growth and stability of charged dislocation loops in ceramic materials with very strong different mass of atoms (stabilized cubic zirconia) under different energies and types of irradiation conditions: 100-1000 keV electrons, 100 keV He sup + and 300 keV O sup + ions. The anomalous formation of extended defect clusters (charged dislocation loops) has been observed by TEM under electron irradiation subsequent to ion irradiation. It is demonstrated that very strong strain field (contrast) near charged dislocation loops is formed. The dislocation loops grow up to a critical size and after then become unstable. The instability of the charged dislocation loop leads to the multiplication of dislocation loops and the formation of dislocation network near the charged dislocation loops. A theoretical model is suggested for the explanation of the growth and stability of the charged dislocation loop, taking the charge state of point defects. The calculated distribution...

  3. Prospective surveillance of phlebitis associated with peripheral intravenous catheters.

    Science.gov (United States)

    Malach, Tal; Jerassy, Ziona; Rudensky, Bernard; Schlesinger, Yechiel; Broide, Etty; Olsha, Oded; Yinnon, Amos M; Raveh, David

    2006-06-01

    Guidelines have been published for prevention of phlebitis associated with peripheral intravenous catheters (IVC), but this complication continues to occur. We sought to determine the rate of phlebitis associated with peripheral IVCs to identify predictors for phlebitis and to isolate pathogenic bacteria from phlebitic catheter tips. Nine-point prevalence studies were conducted during the years 1996-2003 of all hospitalized patients with a peripheral IVC. During the last 3 surveys, conducted in 2003, phlebitic lines were removed, and, for each line, 1 to 2 nonphlebitic lines, in place for 48 to 72 hours, were removed and cultured as controls. In between these surveys, findings and guidelines for improvement were distributed to the staff. During these surveys, 40% +/- 8% of hospitalized patients had a peripheral IVC. The rate of peripheral IVC-associated phlebitis decreased from 12.7% (20/157) in 1998 to 2.6% (5/189) in 2003 (P phlebitis included pain (P phlebitis associated with peripheral intravenous catheters decreased significantly throughout the study period. The identification of predictors for phlebitis and the dissemination of this information in an educational drive may have contributed to this improvement.

  4. Inductive Loops for Sensing Position as Signature Signals

    International Nuclear Information System (INIS)

    Larbani, Sofiane; Malik, Noreha Abdul; Nordin, Anis Norashikin; Khan, Sheroz; Shobaki, Mohammad

    2013-01-01

    In this paper, an inductive sensing technique made of a special shaped inductive loop is proposed. The inductive loop has an inner turn fitted within an outer turn, making a total inductance value 100μH. This loop is made to be shown with balanced response using three capacitance values of 0.068μF each when a sinusoidal voltage source of 5V peak-to-peak is applied. The variation of the relative permeability of the inductance of the inductive loop (AL) results in a variation of the overall inductance value (L+AL), that causes the output signal to change in term of shape and amplitude for variation of total inductance sweep over a given period of time. As a result of change in inductance value (lμH) there is a correspondence increase of 300mV. Theoretical derivations have showed in close agreement with the simulation plots obtained using Multisim software

  5. Inductive Loops for Sensing Position as Signature Signals

    Science.gov (United States)

    Larbani, Sofiane; Malik, Noreha Abdul; Norashikin Nordin, Anis; Khan, Sheroz; Shobaki, Mohammad

    2013-12-01

    In this paper, an inductive sensing technique made of a special shaped inductive loop is proposed. The inductive loop has an inner turn fitted within an outer turn, making a total inductance value 100μH. This loop is made to be shown with balanced response using three capacitance values of 0.068μF each when a sinusoidal voltage source of 5V peak-to-peak is applied. The variation of the relative permeability of the inductance of the inductive loop (AL) results in a variation of the overall inductance value (L+AL), that causes the output signal to change in term of shape and amplitude for variation of total inductance sweep over a given period of time. As a result of change in inductance value (lμH) there is a correspondence increase of 300mV. Theoretical derivations have showed in close agreement with the simulation plots obtained using Multisim software.

  6. Higgs bosons and QCD jets at two loops

    International Nuclear Information System (INIS)

    Koukoutsakis, Athanasios

    2003-04-01

    In this thesis we present techniques for the calculation of two-loop integrals contributing to the virtual corrections to physical processes with three on-shell and one off-shell external particles. First, we describe a set of basic tools that simplify the manipulation of complicated two-loop integrals. A technique for deriving helicity amplitudes with use of a set of projectors is demonstrated. Then we present an algorithm, introduced by Laporta, that helps reduce all possible two-loop integrals to a basic set of 'master integrals'. Subsequently, these master integrals are analytically evaluated by deriving and solving differential equations on the external scales of the process. Two-loop matrix elements and helicity amplitudes are calculated for the physical processes γ* → qq-barg and H → ggg respectively. Conventional Dimensional Regularization is used in the evaluation of Feynman diagrams. For both processes the infrared singular behavior is shown to agree with the one predicted by Catani. (author)

  7. Peripheral ossifying fibroma of oral cavity: histopathologic differential diagnoses.

    Science.gov (United States)

    Shamim, Thorakkal

    2012-01-01

    Peripheral ossifying fibroma is a benign neoplasm that usuallydevelops from gingiva, presenting as an exophytic smooth surfaced pink or red nodular mass that is sessile or is less frequently seen on a pedicle. From the Indian perspective, it is usually noticed in 5th-6th decades of life with female predilection. Microscopically, the tumour shows stratified squamous epithelium and highly cellular fibrous stroma, sparse endothelial proliferation with fibroblasts and dystrophic calcifications. It has to be differentiated histopathologically from pyogenic granuloma, fibroma, peripheral giant cell granuloma, peripheral odontogenic fibroma and fibrous hyperplasia. A case of peripheral ossifying fibroma of maxillary gingiva in a 55-year-old Indian woman is reported.

  8. MRI features of tuberculosis of peripheral joints

    Energy Technology Data Exchange (ETDEWEB)

    Sawlani, V.; Chandra, T.; Mishra, R.N.; Aggarwal, A.; Jain, U.K.; Gujral, R.B. E-mail: gujralrb@sgpgi.ac.in

    2003-10-01

    The aim of this article is to present the magnetic resonance imaging (MRI) features of peripheral tubercular arthritis. The clinical presentation of peripheral tubercular arthritis is variable and simulates other chronic inflammatory arthritic disorders. MRI is a highly sensitive technique which demonstrates fine anatomical details and identifies the early changes of arthritis, which are not visible on radiographs. The MRI features of tubercular arthritis include synovitis, effusion, central and peripheral erosions, active and chronic pannus, abscess, bone chips and hypo-intense synovium. These imaging features in an appropriate clinical setting may help in the diagnosis of tubercular arthritis. Early diagnosis and treatment can effectively eliminate the long-term morbidity of joints affected by tuberculosis.

  9. MRI features of tuberculosis of peripheral joints

    International Nuclear Information System (INIS)

    Sawlani, V.; Chandra, T.; Mishra, R.N.; Aggarwal, A.; Jain, U.K.; Gujral, R.B.

    2003-01-01

    The aim of this article is to present the magnetic resonance imaging (MRI) features of peripheral tubercular arthritis. The clinical presentation of peripheral tubercular arthritis is variable and simulates other chronic inflammatory arthritic disorders. MRI is a highly sensitive technique which demonstrates fine anatomical details and identifies the early changes of arthritis, which are not visible on radiographs. The MRI features of tubercular arthritis include synovitis, effusion, central and peripheral erosions, active and chronic pannus, abscess, bone chips and hypo-intense synovium. These imaging features in an appropriate clinical setting may help in the diagnosis of tubercular arthritis. Early diagnosis and treatment can effectively eliminate the long-term morbidity of joints affected by tuberculosis

  10. Contrast-enhanced peripheral MRA. Technique and contrast agents

    International Nuclear Information System (INIS)

    Nielsen, Yousef W.; Thomsen, Henrik S.

    2012-01-01

    In the last decade contrast-enhanced magnetic resonance angiography (CE-MRA) has gained wide acceptance as a valuable tool in the diagnostic work-up of patients with peripheral arterial disease. This review presents current concepts in peripheral CE-MRA with emphasis on MRI technique and contrast agents. Peripheral CE-MRA is defined as an MR angiogram of the arteries from the aortic bifurcation to the feet. Advantages of CE-MRA include minimal invasiveness and lack of ionizing radiation. The basic technique employed for peripheral CE-MRA is the bolus-chase method. With this method a paramagnetic MRI contrast agent is injected intravenously and T1-weighted images are acquired in the subsequent arterial first-pass phase. In order to achieve high quality MR angiograms without interfering venous contamination or artifacts, a number of factors need to be taken into account. This includes magnetic field strength of the MRI system, receiver coil configuration, use of parallel imaging, contrast bolus timing technique, and k-space filling strategies. Furthermore, it is possible to optimize peripheral CE-MRA using venous compression techniques, hybrid scan protocols, time-resolved imaging, and steady-state MRA. Gadolinium(Gd)-based contrast agents are used for CE-MRA of the peripheral arteries. Extracellular Gd agents have a pharmacokinetic profile similar to iodinated contrast media. Accordingly, these agents are employed for first-pass MRA. Blood-pool Gd-based agents are characterized by prolonged intravascular stay, due to macromolecular structure or protein binding. These agents can be used for first-pass, as well as steady-state MRA. Some Gd-based contrast agents with low thermodynamic stability have been linked to development of nephrogenic systemic fibrosis in patients with severe renal insufficiency. Using optimized technique and a stable MRI contrast agent, peripheral CE-MRA is a safe procedure with diagnostic accuracy close to that of conventional catheter X

  11. Associations between peripheral vertigo and gastroesophageal reflux disease.

    Science.gov (United States)

    Viliušytė, Edita; Macaitytė, Raminta; Vaitkus, Antanas; Rastenytė, Daiva

    2015-09-01

    We hypothesize that peripheral vertigo is associated with gastroesophageal reflux disease (GERD). Two mechanisms could be considered – gastric acids may directly irritate the respiratory mucosa and cause inflammation, or Helicobacter pylori (H. pylori) could be present and cause local infection. Reflux material (Hydrochloric acid (HCl) and pepsin) could get into the middle ear via Eustachian tube and affect osseous structures directly. Disturbance of ossicles could cause tinnitus, which is more common for peripheral vertigo. H. pylori could also get in the esophagus and in the upper respiratory tract via gastroesophageal reflux, and could cause tympanosclerosis and fixation of ossicles. In our study group, 120 of 153 (78.4%) patients had gastroesophageal reflux disease (GERD). Diagnostic tests of H. pylori (rapid urease test or blood antibody test) were performed for 96 of 120 (80%) patients with GERD and were found positive for 32 of 96 (33.3%) patients. Peripheral vertigo was present in 93 of 120 (77.6%) patients with GERD compared to 33 of 126 (26%) patients without GERD (χ(2)=9.016, p=0.003). H. pylori and peripheral vertigo coexisted in 26 of 126 patients (20.6%) (OR 1.36; 95% CI 0.49-3.74, p=0.55). Our study demonstrated statistically significant association between peripheral vertigo and GERD but not between peripheral vertigo and H. pylori. Further more extensive investigations are needed in order to explore our hypothesis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. CFD simulation of a four-loop PWR at asymmetric operation conditions

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Jian-Ping; Yan, Li-Ming; Li, Feng-Chen, E-mail: lifch@hit.edu.cn

    2016-04-15

    Highlights: • A CFD numerical simulation procedure was established for simulating RPV of VVER-1000. • The established CFD approach was validated by comparing with available data. • Thermal hydraulic characteristics under asymmetric operation condition were investigated. • Apparent influences of the shutdown loop on its neighboring loops were obtained. - Abstract: The pressurized water reactor (PWR) with multiple loops may have abnormal working conditions with coolant pumps out of running in some loops. In this paper, a computational fluid dynamics (CFD) numerical study of the four-loop VVER-1000 PWR pressure vessel model was presented. Numerical simulations of the thermohydrodynamic characteristics in the pressure vessel were carried out at different inlet conditions with four and three loops running, respectively. At normal stead-state condition (four-loop running), different parameters were obtained for the full fluid domain, including pressure losses across different parts, pressure, velocity and temperature distributions in the reactor pressure vessel (RPV) and mass flow distribution of the coolant at the inlet of reactor core. The obtained results for pressure losses matched with the experimental reference values of the VVER-1000 PWR at Tianwan nuclear power plant (NPP). For most fuel assemblies (FAs), the inlet flow rates presented a symmetrical distribution about the center under full-loop operation conditions, which accorded with the practical distribution. These results indicate that it is now possible to study the dynamic transition process between different asymmetric operation conditions in a multi-loop PWR using the established CFD method.

  13. On the determination of loop nature in the TEM

    International Nuclear Information System (INIS)

    Jenkins, M.L.

    1997-01-01

    The two direct methods available for determining the nature of small clusters, were studied. Experiments in heavy-ion irradiated Ag and Cu, including comparisons with Black-White contrast analysis (B-W), forced us to conclude that use of the 2-1/2D technique for analysis of faulted loops is impossible because of reciprocal-lattice spike and other effects. We used B-W analysis to study the clusters produced by RT heavy-ion irradiation of Cu. In-situ irradiations were performed in Argonne HVEM-Tandem Facility using 40 and 80 keV Kr + ions. Nearly all the analysable first-layer loops were vacancy in nature. Some deeper cluster were also certainly vacancy. There is no unequivocal evidence for interstitial loops under these conditions. The near impossibility of establishing that interstitial loops are not present, is shown by the fact that a large fraction of loops (over 50%) could not be analyzed either because they did not display clear B-W contrast under any condition or sufficiently consistent B-W contrast under several different operating conditions

  14. Tiling arbitrarily nested loops by means of the transitive

    Directory of Open Access Journals (Sweden)

    Bielecki Włodzimierz

    2016-12-01

    Full Text Available A novel approach to generation of tiled code for arbitrarily nested loops is presented. It is derived via a combination of the polyhedral and iteration space slicing frameworks. Instead of program transformations represented by a set of affine functions, one for each statement, it uses the transitive closure of a loop nest dependence graph to carry out corrections of original rectangular tiles so that all dependences of the original loop nest are preserved under the lexicographic order of target tiles. Parallel tiled code can be generated on the basis of valid serial tiled code by means of applying affine transformations or transitive closure using on input an inter-tile dependence graph whose vertices are represented by target tiles while edges connect dependent target tiles. We demonstrate how a relation describing such a graph can be formed. The main merit of the presented approach in comparison with the well-known ones is that it does not require full permutability of loops to generate both serial and parallel tiled codes; this increases the scope of loop nests to be tiled.

  15. On the duality-transformed Wilson loop operator

    International Nuclear Information System (INIS)

    Mizrachi, L.

    1981-08-01

    Duality transformation of the vacuum expectation value of the Wilson loop operator is performed in the radial gauge (xsub(μ)Asub(μ)sup(a)(x) = 0). It is found to be equal, up to a multiplicative constant, to , where O(c) is a line integral along the loop c (defining the Wilson loop operator) of a function of the dual field variables. In the weak coupling region self duality is recovered in the sense that the Lagrangian is local gauge invariant defined in terms of the dual gauge potentials but with g (the coupling constant) replaced by 1/g, and O(c) is simply the line integral of the dual gauge potentials. For large g, a strong coupling expansion is suggested (but the theory is not local gauge invariant). (author)

  16. Automatic Loop Parallelization via Compiler Guided Refactoring

    DEFF Research Database (Denmark)

    Larsen, Per; Ladelsky, Razya; Lidman, Jacob

    For many parallel applications, performance relies not on instruction-level parallelism, but on loop-level parallelism. Unfortunately, many modern applications are written in ways that obstruct automatic loop parallelization. Since we cannot identify sufficient parallelization opportunities...... for these codes in a static, off-line compiler, we developed an interactive compilation feedback system that guides the programmer in iteratively modifying application source, thereby improving the compiler’s ability to generate loop-parallel code. We use this compilation system to modify two sequential...... benchmarks, finding that the code parallelized in this way runs up to 8.3 times faster on an octo-core Intel Xeon 5570 system and up to 12.5 times faster on a quad-core IBM POWER6 system. Benchmark performance varies significantly between the systems. This suggests that semi-automatic parallelization should...

  17. Mechanism of formation of loop-type prominences

    International Nuclear Information System (INIS)

    Uralov, A.M.; Fedorov, L.V.

    1978-01-01

    Chromospheric gas heated to high temperatures flows out to the corona, filling and carrying up arches of the coronal magnetic field. Under the action of the magnetic tension and of the gravitation, a part of matter contained in the field tubes begins to fall back. The magnetic pressure of the magnetic loop reduced to its original size prevents the vertical fall of gas. At the loop top, braking of gas is most significant, due to field quasi-transversality. Here, in the first place gas compression and cooling by emission of radiation occurs, the already visible matter thereafter flowing away from the condensation point, thus marking the loop contours. A continuous return to the state of equilibrium of new field tubes with matter leads to an apparent ascent of the arch structure into the corona

  18. Molecular Velcro constructed from polymer loop brushes showing enhanced adhesion force

    Science.gov (United States)

    Zhou, Tian; Han, Biao; Han, Lin; Li, Christopher; Department of Materials Science; Engineering Team; School of Biomedical Engineering, Science; Health Systems Team

    2015-03-01

    Molecular Velcro is commonly seen in biological systems as the formation of strong physical entanglement at molecular scale could induce strong adhesion, which is crucial to many biological processes. To mimic this structure, we designed, and fabricated polymer loop brushes using polymer single crystals with desired surface functionality and controlled chain folding. Compared with reported loop brushes fabricated using triblock copolymers, the present loop bushes have precise loop sizes, loop grafting density, and well controlled tethering locations on the solid surface. Atomic force microscopy-based force spectroscopy measurements using a polymer chain coated probe reveal that the adhesion force are significantly enhanced on the loop brush surface as compared with its single-strand counterpart. This study directly shows the effect of polymer brush conformation on their properties, and suggests a promising strategy for advanced polymer surface design.

  19. Use of helicity methods in evaluating loop integrals: a QCD example

    International Nuclear Information System (INIS)

    Koerner, J.G.; Sieben, P.

    1991-01-01

    We discuss the use of helicity methods in evaluating loop diagrams by analyzing a specific example: the one-loop concentration to e + e - → qanti qg in massless QCD. By using covariant helicity representations for the spinor and vector wave functins we obtain the helicity amplitudes directly from the Feynman loop diagrams by covariant contraction. The necessary loop integrations are considerably simplified since one encounters only scalar loop integrals after contraction. We discuss crossing relations that allow one to obtain the corresponding one-loop helicity amplitudes for the crossed processes as e.g. qanti q → (W, Z, γ * ) + g including the real photon cases. As we treat the spin degrees of freedom in four dimensions and only continue momenta to n dimensions (dimensional reduction scheme) we explicate how our results are related to the usual dimensional regularization results. (orig.)

  20. Peripheral Neuropathy: A Practical Approach to Diagnosis and Symptom Management.

    Science.gov (United States)

    Watson, James C; Dyck, P James B

    2015-07-01

    Peripheral neuropathy is one of the most prevalent neurologic conditions encountered by physicians of all specialties. Physicians are faced with 3 distinct challenges in caring for patients with peripheral neuropathy: (1) how to efficiently and effectively screen (in less than 2 minutes) an asymptomatic patient for peripheral neuropathy when they have a disorder in which peripheral neuropathy is highly prevalent (eg, diabetes mellitus), (2) how to clinically stratify patients presenting with symptoms of neuropathy to determine who would benefit from specialty consultation and what testing is appropriate for those who do not need consultation, and (3) how to treat the symptoms of painful peripheral neuropathy. In this concise review, we address these 3 common clinical scenarios. Easily defined clinical patterns of involvement are used to identify patients in need of neurologic consultation, the yield of laboratory and other diagnostic testing is reviewed for the evaluation of length-dependent, sensorimotor peripheral neuropathies (the most common form of neuropathy), and an algorithmic approach with dosing recommendations is provided for the treatment of neuropathic pain associated with peripheral neuropathy. Copyright © 2015 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.